WorldWideScience
1

Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation  

Science.gov (United States)

This investigation describes the technique for the detection of the X-ray fluorescent radiation

1972-01-01

2

x - NASA Technical Reports Server  

Science.gov (United States)

Mar 1, 2011 ... Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation ...

3

ASE FILE  

Science.gov (United States)

radionuclide X-ray fluorescence analysis: the resolving power of the ... The radiation detectors used in radionuclide X-ray fluorescence ...

4

Nondestructive determination of airborne lead particulates by the radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).

1980-01-01

5

3. Physical foundations and methodology of radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The physical foundations are described of radionuclide X-ray fluorescence analysis (RXFA) and the table shows the values of K- and L-absorption thresholds and the K- and L-line energies of elements. The calculation of the intensity of characteristic radiation during RXFA proceeds from relations derived for conventional X-ray fluorescence analysis. The choice of the radionuclide source is ruled by the nature of the analysed substance and the used detection technique. The diagram shows the areas of radionuclide sources and the energy of the fluorescence radiation of elements. The table shows the spectra of radionuclide sources suitable for the purposes of RXFA measured by semiconductor Si(Li) and Ge(Li) detectors. (ES).

1983-12-01

6

X-ray fluorescence analysis as auxiliary method of restorers  

International Nuclear Information System (INIS)

The principle is described of X-ray fluorescence analysis and the manner of detecting the emitted characteristic radiation. The advantages are presented of radionuclide X-ray fluorescence analysis which consist primarily in the possibility of conducting a totally non-destructive analysis, and of accurate and relatively narrow localization of the analyzed area, the simultaneous qualitative and quantitative determinations of a large number of elements in the order of concentrations 10"1 to 10"-"4%, stability of excitation radiation flux, simple design and relatively low capital costs. The so-called matrix effect is pointed to. A number of examples is given of the use of the cited method, including its use in the analysis of art objects. (J.B.).

1987-09-07

7

Radionuclide X-ray fluorescence analysis. 1: Excitation of X-ray fluorescense radiation by nuclear radiation  

Science.gov (United States)

The principles of radionuclide excitation of X-ray fluorescence radiation and its application in

1972-01-01

8

Radionuclide X-ray fluorescence analysis. 3: Examples of application in practice  

Science.gov (United States)

Examples are given of the applicability and importance of radionuclide fluorescence analysis as a

1973-01-01

9

X-Ray Fluorescence Analysis of Composite Propellants for ...  

Science.gov (United States)

... The constancy of the X-ray intensity ratio for each element in Table 8 as the X-ray tube settings were changed shows the excellent compensating ...

1977-06-03

10

A Virtual Young's Double Slit Experiment for Hard X-ray Photons  

CERN Document Server

We have implemented a virtual Young's double slit experiment for hard X-ray photons with micro-fabricated bi-prisms. We observe fringe patterns with a scintillator, and quantify interferograms by detecting X-ray fluorescence from a scanned 30nm Cr metal film. The observed intensities are best modeled with a near-field, Fresnel analysis. The maximum fringe number in the overlap region is proportional to the ratio of real to imaginary parts refractive index of the prism material. The horizontal and vertical transverse coherence lengths at beamline APS 8-ID are measured.

2009-01-01

11

NASA Technical Reports Server - Radionuclide X-ray fluorescence ...  

Science.gov (United States)

Aug 1, 1972 ... The principles of radionuclide excitation of X-ray fluorescence radiation and its application in analytic chemistry are discussed.

12

The use of x-ray fluorescence in the detection of inorganic elements in medicines drugs  

International Nuclear Information System (INIS)

Based on the instrumental wavelength dispersive X-ray fluorescence technique of analysis (W D-X R F), the inorganic elements in four samples of commercial medicines drugs were analyzed. The samples were used without any chemical separation of the elements or chemical pre-treatment. Eleven elements could be identified, namely Si, P, S, Cl, K, Ca, Ti, Mn, Fe, Cu and Zn. However, Si, Ti and Mn have not been mentioned in the printed instructions for the use of the medicines drugs by the producers. (author)

15

Radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Slovak 1973. 164 p. Czechoslovakia Havranek, E. Bumbalova, A. Svitel,

1973-01-01

16

NONDESTRUCTIVE DETERMINATION OF AIRBORNE LEAD ...  

Science.gov (United States)

... NONDESTRUCTIVE DETERMINATION OF AIRBORNE LEAD PARTICULATES BY THE RADIONUCLIDE X-RAY FLUORESCENCE ANALYSIS. ...

19

Radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The author's achievements in the title field are summarized and discussed. The following topics are dealt with: (i) principles of radionuclide X-ray fluorescence analysis; (ii) mathematical methods in X-ray fluorescence analysis; (iii) Ross differential filters; (iv) application of radionuclide X-ray fluorescence analysis in the coal industry (with emphasis on the determination of the ash content, sulfur content, and arsenic content of coal); and (v) evaluation of the X-ray fluorescence analyzer from the radiological safety point of view. (P.A.).

1994-01-01

20

Measurements of K-shell x-ray production cross sections and K to L and M-shell radiative vacancy transfer probabilities for Nd, Eu, Gd, Dy and Ho at excitation with 59.5 keV photons in an external magnetic field  

International Nuclear Information System (INIS)

The effect of the #+-# 0.75 T external magnetic field on the K_#alpha#_1, K_#alpha#_2, K_#beta#_'_1 and K_#beta#_'_2 x-ray production cross sections and radiative vacancy transfer probabilities from K-shell to L2 and L3 subshells and M-shell for ferromagnetic Nd, Gd and Dy and paramagnetic Eu and Ho have been investigated, using the 59.5 keV incident photons. K-shell fluorescence yields and K x-ray intensity ratios for these elements have been determined in the external magnetic field also. The K x-rays from different targets were detected using a high-resolution Si(Li) semiconductor detector. For B = 0, the present experimental results were compared with the experimental and theoretical data in the literature. The results show that K-shell fluorescence parameters such as photoionization cross section, fluorescence yield, radiation rates, ...

2006-06-19

21

Multielement analysis of air samples. Determination of iron, zinc, lead, and bromine content by the radionuclide X-ray fluorescence analysis  

Energy Technology Data Exchange (ETDEWEB)

Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A /sup 238/Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed.

1981-01-01

22

Determination of ash content in coal by means of backscattered X-ray radiation and X-ray fluorescence analysis, and devices manufactured by the PAR company  

Energy Technology Data Exchange (ETDEWEB)

Discusses methods for determining ash content in coal using backscattering in X-ray fluorescence. The following aspects are evaluated: principle of ash content determination, energy sources, factors that influence measurement accuracy, reliability. Types of X-ray fluorescence analyzers developed in Czechoslovakia and manufactured in the Czech Republic are comparatively evaluated. Operation of the RPM 113.1 radionuclide X-ray fluorescence analyzer developed by the PAR company and used for measuring ash content in coal and coal calorific value is discussed. 7 refs.

1993-09-01

23

Instruments for X-ray fluorescence analysis and spectrometry  

International Nuclear Information System (INIS)

The radionuclide X-ray fluorescence analyzer consists of a source changer and a sample changer. "5"5Fe, "1"0"9Cd and "2"4"1Am are used as excitation sources. The radiation is detected with a semiconductor Si(Li) detector. The complete assembly of the apparatus consists of an imagine unit, a keyboard, a floppy disc drive, a printer, a console and a rack with analog and digital electronics. Its multichannel amplitude analyzer consists of power supplies, a high voltage supply, a linear amplifier, an analog-to-digital converter and a computer. The technical specifications are given. The control and data processing system is controlled with an MHB 8080A microprocessor. Software for semiconductor gamma spectrometry and for quantitative gamma spectrometry will be supplied with the equipment. (E.S.). 3 figs., 4 refs.

24

K/sub. beta. //K/sub. cap alpha. / transition probability ratios from the measurement of fluorescent X-ray intensities of some lanthanide compounds  

Energy Technology Data Exchange (ETDEWEB)

The effect that different chemical and physical atomic environments can have on the relative intensities of radiative electron transitions from the filling of K shell vacancies was investigated. The method used involved the detection of photoionization induced X-ray fluorescence. An experimental system based on a hyper pure germanium detector (HPGE) was used to measure the relative K-L and K-M X-ray yields from the photofluorescence of a series of lanthanide elements and compounds. A background subtraction and peak integration strategy was employed which accounted for scattering in the samples and scattering of the flux from the radioisotope photoionization sources. Analysis of the data resulted in a tabulation of relative K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ratios. The measured relative K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ...

1987-01-01

25

K/sub #beta#//K/sub #alpha#/ transition probability ratios from the measurement of fluorescent X-ray intensities of some lanthanide compounds  

International Nuclear Information System (INIS)

The effect that different chemical and physical atomic environments can have on the relative intensities of radiative electron transitions from the filling of K shell vacancies was investigated. The method used involved the detection of photoionization induced X-ray fluorescence. An experimental system based on a hyper pure germanium detector (HPGE) was used to measure the relative K-L and K-M X-ray yields from the photofluorescence of a series of lanthanide elements and compounds. A background subtraction and peak integration strategy was employed which accounted for scattering in the samples and scattering of the flux from the radioisotope photoionization sources. Analysis of the data resulted in a tabulation of relative K/sub #beta#//K/sub #alpha#/ X-ray intensity ratios. The measured relative K/sub #beta#//K/sub #alpha#/ X-ray intensity ratios were compared ...

1987-01-01

26

Some optimization measurements and parameters of a radionuclide X-ray fluorescence spectrometer  

International Nuclear Information System (INIS)

An irradiation head with sample holders is described and measurement geometry is reported. Measurements were made for optimizing the distance between the source and the sample and for optimizing the sample diameter. The optimal distance between the source and the sample does not depend on the collimator diameter. The sample diameter should not exceed 30 - 35 mm. Sensitivity and detection limits were determined for Zn, Pb and Br and calibration curves were plotted. (M.D.) 6 figs., 2 tabs., 4 refs.

1986-01-01

27

Identification and determination of elements in Taraxacum officinale plant from different Bratislava localities  

Energy Technology Data Exchange (ETDEWEB)

Elements Ti, Mn, Fe, Ni, Cu, Zn, Pb, Br, Rb and Sr were determined by the method of radionuclide X-ray fluorescence analysis with semiconductor detection in samples of Taraxacum officinale from various localities of Bratislava. The dependence of their content on the source and the degree of the air pollution was found out.

1983-01-01

28

Identification and determination of elements in Taraxacum officinale plant from different Bratislava localities  

International Nuclear Information System (INIS)

Elements Ti, Mn, Fe, Ni, Cu, Zn, Pb, Br, Rb and Sr were determined by the method of radionuclide X-ray fluorescence analysis with semiconductor detection in samples of Taraxacum officinale from various localities of Bratislava. The dependence of their content on the source and the degree of the air pollution was found out. (author).

1983-01-01

29

Heavy metals in welding fumes  

Energy Technology Data Exchange (ETDEWEB)

Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A /sup 241/Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer.

1984-10-01

30

Heavy metals in welding fumes  

International Nuclear Information System (INIS)

Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A "2"4"1Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer. (E.S.).

1984-01-01

31

Radionuclide X-ray fluorescence analysis of waste water from the production of citric acid  

Energy Technology Data Exchange (ETDEWEB)

Radionuclide X-ray fluorescence analysis was used for the determination of iron, calcium, potassium, copper, manganese and zinc in waste water from the production process of citric acid.

1982-02-18

32

Radionuclide X-ray fluorescence analysis of waste water from the production of citric acid  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis was used for the determination of iron, calcium, potassium, copper, manganese and zinc in waste water from the production process of citric acid. (author).

1982-02-01

33

Contribution to the radionuclide x-ray fluorescence analysis of human blood and plasma  

International Nuclear Information System (INIS)

A photon-induced x-ray fluorescence method allowing the simultaneous determination of iron, copper, zinc, bromine and rubidium in human blood and blood plasma samples is described. The method is reliable and has a good sensitivity for a wide range of elements. (author).

1986-04-01

34

8. Application of radionuclide X-ray fluorescence analysis in other fields of science and technology  

International Nuclear Information System (INIS)

Certain applications are described of radionuclide X-ray fluorescence analysis in the ore dressing industry, in the manufacture of building materials, in metallurgy, pharmacy, in the chemical, photographic and paper industries, in space exploration, in archeology and for measuring the thicknesses of thin layers of coatings. (ES).

1983-12-01

35

Multielement analysis of air samples  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A "2"3"8Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed. (author).

1981-01-01

36

Radionuclide X-ray fluorescence analysis using semiconductor detectors  

International Nuclear Information System (INIS)

Czech May 1979. p. 32-33. Czechoslovakia Benada, J. Spacek, B. Ustav

1979-05-01

37
38

Microcomputers in radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Czech Apr 1986. p. 51. Czechoslovakia Cechak, T. Kluson, J. Ceske

1986-04-01

39

Radionuclide X-ray fluorescence analysis of components of the environment  

International Nuclear Information System (INIS)

The physical foundations and methodology are described of radionuclide X-ray fluorescence analysis. The sources are listed of air, water and soil pollution, and the transfer of impurities into biological materials is described. A detailed description is presented of the sampling of air, soil and biological materials and their preparation for analysis. Greatest attention is devoted to radionuclide X-ray fluorescence analysis of the components of the environment. (ES).

1983-01-01

40

Present state of radionuclide X-ray fluorescence analysis in coal mining  

International Nuclear Information System (INIS)

Applications of X-ray fluorescence analysis in coal mining and geology are briefly described based on results published in Czechoslovakia as well as abroad over the past 3 years. Particular attention is paid to the rapid determination of the ash content of coal using portable radionuclide X-ray fluorescence analyzers that are being developed in Czechoslovakia. (author).

1990-01-01

41

Contribution to the in vitro multielement X-ray fluorescence analysis of human soft tissues  

International Nuclear Information System (INIS)

Determination of Mn, Fe, Ni, Cu, Zn, and Pb in human soft tissues by radionuclide X-ray fluorescence analysis (using "2"3"8Pu and "1"0"9Cd sources) is described. The results of multielement XRS analysis of selected human tissues are tabulated. They are in good agreement with the literature data. It is concluded that X-ray fluorescence technique is a suitable method for trace element determination. (author).

1986-11-01

42

Alloying effect on K to L shell vacancy transfer probabilities in 3d transition metals  

British Library Electronic Table of Contents (United Kingdom)

The alloying effects on K to L shell vacancy transfer probabilities (?KL) in 3d transition metals have been carried out by X-ray fluorescence studies of various alloy compositions. K X-ray intensity ratios of Ti, Cr, Fe, Co, Ni, and Cu elements in the FexNi1?x, FexCr1?x, NixCr1?x, FexCryNi1?(x+y), TixNi1?x, TixCo1?x, and CoxCu1?x alloys have been measured following excitation by 22.69keV X-rays from a 10 mCi 109Cd radioactive point source and ?KL values for alloying elements have been determined from these ratios. The spectrum of characteristic K-X-ray photons from samples were detected with a high resolution Si(Li) detector coupled to a 4 K multichannel analyzer. The present investigation makes it possible to ...

2010-01-01

43

X-Ray Fluorescence in Research on the Cultural Heritage  

Energy Technology Data Exchange (ETDEWEB)

Radionuclide X-ray fluorescence analysis is a method, which has many advantages for analysing various historic artefacts, as it is relatively cheap, sensitive and non-destructive, and it allows measurements in-situ. However, this analysis has also certain limitations especially concerning sensitivity to chemical elements only, irrespective of the compounds or chemical forms in which these elements have been bonded. In addition, light elements emitting very soft X-rays cannot be measured, and in order to detect a wide range of elements, it is necessary to carry out repeated measurements with different radiation sources. Despite these limitations, valuable information can be obtained about the composition of historic materials and data about the origin and age of these artefacts can be derived. Analyses of wall paintings, ancient metal sculptures or other objects of art provide the basis for historic ...

2001-09-15

44

X-Ray Fluorescence in Research on the Cultural Heritage  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis is a method, which has many advantages for analysing various historic artefacts, as it is relatively cheap, sensitive and non-destructive, and it allows measurements in-situ. However, this analysis has also certain limitations especially concerning sensitivity to chemical elements only, irrespective of the compounds or chemical forms in which these elements have been bonded. In addition, light elements emitting very soft X-rays cannot be measured, and in order to detect a wide range of elements, it is necessary to carry out repeated measurements with different radiation sources. Despite these limitations, valuable information can be obtained about the composition of historic materials and data about the origin and age of these artefacts can be derived. Analyses of wall paintings, ancient metal sculptures or other objects of art provide the basis for historic ...

2001-09-01

45

Analytic description of X-ray fluorescence intensity as a function of the particle size in powder samples and pulp upon X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Analytic expression is derived for X-ray fluorescence dependence on the particle size of powder and slurry media. The expression is obtained for a model of powder medium containing particles of different size and random distribution in the bulk of the sample. Limiting cases of homogeneous and slurry-like media are considered and expressions for calculation of the fluorescence intensity are derived. The results reasonably match the experiment for binary powder mixtures and thus provide evaluation of the powder particle size on the fluorescence intensity for multicomponent polydisperse powder medium

2007-11-01

46

Programmable radionuclide X-ray fluorescence multi-channel spectrometric analyzer, type 123-1  

International Nuclear Information System (INIS)

The whole equipment consists of three separate portable parts: a detector case, a microprocessor and a graphic TV monitor. Magnetic tape memory and an x-y recorder can be connected for recording the measured spectra. The analyzer contains two built-in exchangeable excitation radionuclides. Fluorescence and scattered radiation is detected using a proportional detector. The detected pulses are analyzed by a 256-channel analyzer and the results are shown on the display. The device may be used in mining laboratories, coal and ore dressing plant control rooms or in mining fields of open cast mines for quick detection of the quality of mined or dressed raw materials. (E.S.). 1 fig.

1988-01-01

47

Determination of ash in coal by X-ray backscattering and X-ray fluorescence analysis and apparatus by the PAR company  

International Nuclear Information System (INIS)

The basic principles of determination of the ash content of coal by the title methods are outlined. A brief technical characteristic of the ash meters and radionuclide X-ray fluorescence analyzers manufactured by the PAR company is presented. (Z.S.). 4 figs., 7 refs.

1993-01-01

48

Investigation by XRF and XRD of Zn and Fe in Fe{sub x} Zn{sub 1-x} thin films  

Energy Technology Data Exchange (ETDEWEB)

Fe{sub x}Zn{sub 1-x} alloys were electrochemically deposited on aluminum substrates from a sulfate bath. The K{beta}/K{alpha} x-ray intensity ratios of Zn and Fe in Fe{sub x}Zn{sub 1-x} thin films have been experimentally studied. The energy dispersive x-ray fluorescence (EDXRF) technique was used to measure K x-ray photons. Samples were excited by using 59.5 keV photons emitted by a 50 mCi {sup 241}Am radioactive source. The emitted K x-rays were detected by an Ultra-LEGe detector having a resolution of 150 eV at 5.9 keV. In addition, the effect of bath composition on the phase structure was investigated by x-ray diffraction (XRD) analysis. The composition of the thin films was analyzed by atomic absorption spectrometry analysis. Iron content was shown to strongly affect the structure of Zn-Fe alloys. It was found that the K-shell ...

2008-12-15

49

Investigation by XRF and XRD of Zn and Fe in Fex Zn1-x thin films  

International Nuclear Information System (INIS)

FexZn1-x alloys were electrochemically deposited on aluminum substrates from a sulfate bath. The K?/K? x-ray intensity ratios of Zn and Fe in FexZn1-x thin films have been experimentally studied. The energy dispersive x-ray fluorescence (EDXRF) technique was used to measure K x-ray photons. Samples were excited by using 59.5 keV photons emitted by a 50 mCi 241Am radioactive source. The emitted K x-rays were detected by an Ultra-LEGe detector having a resolution of 150 eV at 5.9 keV. In addition, the effect of bath composition on the phase structure was investigated by x-ray diffraction (XRD) analysis. The composition of the thin films was analyzed by atomic absorption spectrometry analysis. Iron content was shown to strongly affect the structure of Zn-Fe alloys. It was found that the K-shell x-ray intensity ratio changed ...

2008-12-01

50

Ultrasensitive fluorescence detection of DNA  

Science.gov (United States)

Progress on Ultrasensitive fluorescence detection of DNA is briefly described. (CBS)

1991-01-01

51

Fluorescent Silicate Materials for the Detection of Paraoxon  

Science.gov (United States)

... significantly lower limits of detection. The complex fluorescence spectra of these constructs indicated that only a portion ...

2010-03-19

52

An Apparent Hard X-ray Decline of CH Cygni  

CERN Document Server

CH Cygni is a symbiotic star consisting of an M giant and an accreting white dwarf, which is known to be a highly variable X-ray source with a complex, two-component, spectra. Here we report on two Suzaku observations of CH Cyg, taken in 2006 January and May, during which the system was seen to be in a soft X-ray bright, hard X-ray faint state. Based on the extraordinary strength of the 6.4 keV fluorescent Fe K-alpha line, we show that the hard X-rays observed with Suzaku are dominated by scattering.

2006-01-01

53

Electron-Induced Luminescence and X-Ray Spectrometer (ELXS) System for Life Detection  

Science.gov (United States)

The ELXS concept is a novel, portable, micro-instrument targeted for the detection of mineralogic

2002-01-01

54

Nondestructive testing of metal coating thickness and control of chemical composition using radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The principle is described of a method using low-activity emitters as the primary radiation source for analysis. The selection of the radiation source and the detection methods including the assessment of the applicability of various radiation detectors are discussed. The benefits and the constraints of the method are considered. Practical examples are presented showing the application possibilities of the method for testing the thickness of bearing layers, piston ring coats, lead layers, etc. The possibility is shown of applying the rapid test for the composition of tungsten and chromium alloyed metal materials in testing complex systems. (J.K.).

1974-12-03

55

Thickness measurement of Sn-Ag hot dip coatings on Large Hadron Collider Superconducting strands by coulometry  

CERN Document Server

Amperostatic coulometry was applied for the thickness measurement of Sn-Ag hot dip coatings, which comprise an extended Sn-Cu interdiffusion layer. Complementary measurements, notably weight loss, X-ray photoelectron spectroscopy, energy-dispersive X-ray spectroscopy, X-ray fluorescence (XRF), and dynamic secondary ion mass spectroscopy were performed in order to obtain a better interpretation of the coulometry results. Based on the experimental results presented in this article, the three potential changes observed during coulometry measurements are ascribed to (i) the entire dissolution of pure Sn, (ii) the formation of a CuCl salt layer, and (iii) the surface passivation. The measurement of the pure Sn mass is well reproducible despite strong coating thickness variations detected by XRF. Several experimental problems, in particular, a coating undercutting, hamper the ...

2004-01-01

56

Application of radionuclide X-ray fluorescence analysis to the monitoring of the quality of air  

International Nuclear Information System (INIS)

An X-ray fluorometric train was set up for analyzing gravitational fallout, and tested on standard reference samples of fly ashes from conventional power plants. Analysis of thin layers proved inappropriate, and therefore pelletization of the samples, either alone or together with the X-ray MIX binder, was applied. Sample grinding in an agate mortar was found sufficient to suppress the particle size effect. The optimum pressure was 20 MPa. The optimum geometry was sought for "1"0"9Cd source, and limits of detection of 2.78-0.47 #mu#g were achieved for Cr-Zr elements. Tominaga's method was employed for matrix effect correction. Ti, Fe, Cu, Zn, As, Rb, Sr, Zr and Pb were determined in the SRM's; the relative errors ranged from units per cent (for Zn, Rb, Sr and Zr present in concentrations about 100 ppm and for Fe in concentrations of units per cent) up to 45% (for Ti present in a concentration of 0.67%). The method developed ...

1990-10-01

57

Radionuclide X-ray fluorescence determination of Mn, Fe, Cu, Zn and Pb in wastewaters and sludges from wastewater treatment plants in Bratislava (SR)  

International Nuclear Information System (INIS)

Radiometric X-ray fluorescence analysis was used for the determination of Mn, Fe, Cu, Zn and Pb in wastewater and sludges from three wastewater treatment plants in Bratislava (SR). Metals were determined in wastewaters after preconcentration by 8-hydroxyquinoline and in sludges by drying and pressing to pellets. "2"3"8Pu and "1"0"9Cd was used for excitation of fluorescence radiation. (author).

1997-01-01

61

PRICES SUBJECT To CHq.G - NASA Technical Report Server (NTRS)  

Science.gov (United States)

by the radionuclide X-ray fluorescence analysis into several groups according to the atomic number of the determined element. Table I documents this. ...

63

Determination of small amounts of elements by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The determination of small amounts of elements by radionuclide X-ray fluorescence analysis is described. Samples containing 5x10"-"4 to 5x10"-"6 g of elements were fixed on a suitable carrier. For a coaxial configuration a low-energy source of the #gamma#/X type was used, namely an annular "2"4"1Am/Ag source with an activity of 7.4x10"8 s"-"1 (20 mCi), and for a configuration with side reflection source of the #beta#/X type was used, namely "1"4"7Pm/Sm with the activity of Pm(OH)_3 approximately 3.7x1O"1"0 s"-"1 (1 Ci). Cs, Ba, La, Pr, Nd, and Ag were determined by means of the Ksub(#alpha#) line and Hg, W, Er, and Pr by means of the Lsub(#alpha#) line. For all elements studied a detection limit of the order of 10"-"7 g was achieved. (author).

1975-01-01

64

Coupling of Pressure-Induced Structural Shifts to Spectral Changes in a Yellow Fluorescent Protein  

UK PubMed Central (United Kingdom)

AbstractX-ray diffraction analysis of pressure-induced structural changes in the Aequorea yellow fluorescent protein Citrine reveals the structural basis for the continuous...Full Text Available

2009-09-16

65

X-Ray Phase Imaging for Breast Cancer Detection  

Science.gov (United States)

... Accession Number : ADA535309. Title : X-Ray Phase Imaging for Breast Cancer Detection. Descriptive Note : Annual rept. 1 Sep 2009-31 Aug 2010 ...

2010-09-01

66

A comparison of patient doses in lumbar spine radiography from various X-ray units in Poland  

Energy Technology Data Exchange (ETDEWEB)

A number of diagnostic X-ray units in Poland were subjected to analysis. The air kerma on X-ray tables was measured for the X-ray parameters used routinely during lumbo-sacral spine radiography of standard adult patient. Measurements of air kerma were performed using TLD made of lithium-fluoride. The doses received by patients in different X-ray departments can differ more than two orders of magnitude (from 0.42 mGy up to 72.11 mGy), for the same X-ray examination. The dose can be significantly reduced if fluorescent screens made from components of rare earth are used. (author). 10 refs, 1 fig., 2 tabs.

1995-12-31

67

Radioanalytical methods of rare earth element determination  

International Nuclear Information System (INIS)

Instrumental neutron activation analysis (INAA) and radionuclide X-ray fluorescence analysis (RXFA) were used for the determination of rare earth elements. For INAA, solution obtained by sample decomposition was dripped onto filter paper, enclosed and sealed into a polyethylene foil. The sample was activated in reactor WWR-S over a period of 4 to 6 hours with a neutron fluence of 10"1"3cm"-"2. Gamma radiation measurement was carried out with a planar and a coaxial HP-Ge detector in three decay periods. La, Ce, Nd, Sm, Eu, Gd, Tb, Ho, Tm, Yb and Lu were determined. The advantage of the method is its accuracy and high sensitivity, the disadvantage is the time-consuming analysis. The RXFA method was used as a rapid and operative method for the analysis of loose ore samples, aqueous and organic solutions of rare earth elements. For exciting X-ray radiation, "2"4"1Am was used and the radiation of K-lines was ...

1989-06-01

68

Radionuclide X-ray fluorescence determination of Cr, Fe, Cu, Zn,and Pb in industrial wastewaters after preconcentration of determined elements  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis was used for the determination of Cr, Fe, Cu, Zn and Ph in industrial wastewaters (from surface treatment of metals and glasses) after precipitation of determined elements by 8-hydroxyquinoline. (author).

1997-01-01

69

Radionuclide X-ray fluorescence analysis of solid aerosol particles on Synpor 4 collection filters  

International Nuclear Information System (INIS)

The feasibility was studied of the application of radionuclide X-ray fluorescence analysis to the identification and determination of chemical elements in the air. A description of the method is presented, the main stages of the analysis are discussed (sample preparation and standards, selection of radioactive radiation sources, geometry of measurement and evaluation of results). The method is illustrated on the determination of elements Fe, Cu, Zn, Br, and Pb in air samples taken in the city of Prague. (author) 2 tabs., 2 figs., 14 refs.

1992-01-01

70

Heavy metals in industrial wastewater determined by radionuclide x-ray fluorescence analysis and their effects on Allium cepa root tip cells  

International Nuclear Information System (INIS)

Radionuclide x-ray fluorescence method was used in the determination of Cr, Ni and other heavy metals content in wastewater of an engineering plant taken both before and after chemical treatment. Toxic effects of the wastewaters using Allium cepa root tip cells were tested. (author) 8 refs.; 2 tabs.

1994-05-01

71

Heavy metals and some other elements in medicinal plants. Determined by X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Determination of Mn, Fe, Cu, Zn, Hg, Pb, Br, Se, Rb, Sr and Cd in the medicinal plants by radionuclide X-ray fluorescence analysis (using "2"3"8Pu, "2"4"1Am/Ag and "1"2"5I) is described. (author). 12 refs., 2 tabs.

1995-01-01

72

Heavy element contamination of surface waters in the region Banska Stiavnica (SR) measured by radionuclide X/ray fluorescence analysis  

International Nuclear Information System (INIS)

Heavy metals (Pb, Cd, Mn, Cu, Zn, Fe) were determined in surface waters in the surroundings of the depositories of the mining shrubs in the region of Banska Stiavnica (SR) by radionuclide X-ray fluorescence analysis. Allowed concentrations of the determined metals are exceeded numerously (multiplicity in some cases was 10"3-10"6). (author).

1997-01-01

73

Evaluation of adhesive plasters by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

A radiometric method was elaborated for surface density determinations of the adhesive layer of plasters by radionuclide X-ray fluorescence using the 17.47 keV bremsstrahlung of "1"4"7Pm/Mo. The bremsstrahlung line excites the 8.63 keV characteristic K#alpha# line of Zn contained in the adhesive layer of the plaster as a filling material in the form of ZnO. In homogeneous adhesive layers the Zn content is proportional to surface density. (author).

1976-01-01

74

Determination of cesium and selenium in cultivated mushrooms using radionuclide X-ray fluorescence technique  

International Nuclear Information System (INIS)

Cesium and selenium intake of cultivated mushrooms (Agaricus bisporus), with these elements previously added to culture medium, has been examined from the viewpoint of health- and environmental protection. The process of measuring has been carried out by the radionuclide X-ray fluorescence technique. Treatments of the elementary substance with Se salt appears to influence the Se content of the mushrooms to a significant extent. Cs intake is of considerable importance, as this element is accumulated by mushrooms. (author)

2000-09-01

75

Determination of Y, Ba and Cu in superconductor films by x-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide x-ray fluorescence analysis was used for the determination of Y, Ba and Cu in thin high-temperature superconducting films. Atomic emission ICP spectrometry was used to estimate the precision and accuracy of analytical results. Reasonable agreement between both methods was obtained when a polynomial calibration curve was applied. (author) 4 refs.; 4 tabs.

1994-06-01

76

Determination of Mn, Fe, Ni, Cu, Zn and Pb contents in samples of apple trees by radionuclide X-ray fluorescence analysis  

Energy Technology Data Exchange (ETDEWEB)

The applicability of the radionuclide X-ray fluorescence analysis (RXFA) for qualitative and quantitative evaluation of environmental plant samples is discussed and examples of determination of Mn, Fe, Ni, Cu, Zn, Pb in samples of apple trees are given. The instrumentation, the standard and sample preparation are also presented.

1982-12-01

77

Determination of Fe and Zn in healing plants by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence method was used for the determination of Fe and Zn in healing plants (Sage, Peppermint, Stinging, Common Agrimony, Milfoil, Ribwort, Tansy, White Dead-Nettle). "2"3"8Pu exciting source and Si/Li semiconductor detector were used for the determination. (author)

1999-06-01

78

Determination of Fe and Zn in agricultural plants with special cultivation by radionuclide x-ray fluorescence analysis  

International Nuclear Information System (INIS)

Fe and Zn were determined in various parts of maize (Zea mays) in dependence on quantity of organic substrate EKOFERT as organic fertilizer in soil, using radionuclide X-ray fluorescence analysis. The increase of quantity of organic substrate EKOFERT in soil causes a decrease of heavy metal concentrations in certain parts of the plant. (author). 4 refs., 1 tab.

1996-01-01

79

Determination of Cu, Ni, Zn and Pb contents in taraxacum officinale near the highway D-61 Bratislava-Trnava (SR) by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence method with Si/Li semiconductor detector and "2"3"8Pu exciting source was used for the determination of Cu, Ni, Zn and Pb in plant samples (Taraxacum officinale) from various localities near the highway D-61 Bratislava-Trnava (SR). (author) 2 refs.; 1 fig.; 1 tab.

1993-12-01

80

Determination of Cu, Ni, Zn and Pb contents in soil near the D-61 Bratislava-Trnava Highway by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence method with Si/Li semiconductor detector and "2"3"8Pu exciting source was used for the determination of Cu, Ni, Pb, and Zn in soil samples from various localities near the D-61 Bratislava-Trnava highway (CSFR). (author) 1 ref.; 1 tab.

1993-01-01

81

Analysis of high-temperature superconducting films by x-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis was used for the determination of Cu, Y and Ba in very thin high-temperature superconducting films. The precision of the method is better than 3% for about 1 #mu#m thick films. The atomic emission ICP spectrometry was used to testify results of XRF analysis. An acceptable agreement of both methods was obtained. (author) 4 refs.; 2 tabs.

1991-09-01

82

7. Overview of radionuclide X-ray fluorescence analysis of components of the environment  

International Nuclear Information System (INIS)

A survey is presented of studies dealing with radionuclide X-ray fluorescence analysis (RXFA) of impurities in the air, water, soil, sediments and biological materials, mainly blood, urine, hair, soft tissues and bones. Tabulated are lists of published works on RXFA of the air, water and biological materials. (ES).

1983-12-01

83

Measurement of M shell X-ray production cross sections and fluorescence yields for the elements in the atomic range 70#<=#Z#<=#92 at 5.96 keV  

International Nuclear Information System (INIS)

Total M X-ray cross sections for 12 elements in atomic range 70#<=#Z#<=#92 were measured at 5.96 keV Mn K X-ray photon energy. The average M shell fluorescence yields (anti #omega#_M) of these elements have also been observed using the presently measured cross section values and the theoretical M shell photoionisation cross section values. (orig.).

84

Inner-shell excitation of intrinsic luminescence and resonantly excited X-ray fluorescence at Be 1s edge in oriented BeO crystals  

International Nuclear Information System (INIS)

The results of studies of the time-resolved luminescence of self-trapped excitons (STE) with different multiplicity as well as the X-ray emission in oriented BeO crystals under excitation in the vicinity of the 1 s Be photoabsorption edge are presented. The branching of the electronic excitations relaxation depends strongly on the crystal orientation after the inner-shell excitation. The common features between the processes of the STE luminescence and resonantly excited X-ray fluorescence have been discussed.

2007-05-21

85

The fluorescence properties and NMR analysis of protopine and allocryptopine  

International Nuclear Information System (INIS)

The fluorescence properties of protopine and allocryptopine in aqueous and organic environments are described for the first time. The fluorescence of alkaloids and their pH-dependent interconversion to cationic forms (transannular interaction) were studied using steady-state and time-resolved fluorescence techniques. For the analysis of tricyclic base and cis/trans tetracyclic cations of the alkaloids, NMR and X-ray crystallography were used. - Highlights: ? We describe fundamental fluorescence characteristics of alkaloids protopine and allocryptopine. ? We analyzed the pH-dependent transitions and cis/trans isomerization. ? These two alkaloids can be better distinguished by their fluorescence decay characteristics. ? The fluorescence parameters are related to the NMR and crystallographic structural data.

2011-07-01

86

A radionuclide analyzer of total sulfur in coal  

International Nuclear Information System (INIS)

The devised radionuclide analyzer for the determination of total sulfur in coal includes two radionuclide sources with different energies, which are accommodated in collimators fitted with adjustable diaphramgs. The sample compartment is located between the two sources. Moreover, an X-ray fluorescence standard can be slid into the sample compartment. A proportional detector for X-ray fluorescence and scattered gamma radiation is located off the sample compartment. The input of the proportional detector is interfaced to the output of a high-voltage supply, the output, to the information input of a control-and-evaluation unit. One of the control outputs of the control-and-evaluation unit is connected to the input of the sliding mechanism for the X-ray fluorescence standard. This arrangement enables automatic energy calibration of the analyzer. The analyzer can ...

1987-05-13

87

Measurement of K x-ray intensity ratio of tin, gadolinium and dysprosium  

International Nuclear Information System (INIS)

Full text: Measurement of K_#beta# to K_#alpha# x-ray intensity ratios are important not only in the field of atomic physics, radiation physics and medical physics, but also to test the validity of assumptions made in the theoretical prediction. The intensity ratios can also give information on the effect of physical and chemical environment of the element in the compound. Many investigators have adopted a single and double reflection geometries to measure the K_#beta# to K_#alpha# x ray intensity ratios to understand the effect of physical and chemical environment on x-ray fluorescence. The targets are excited by a radioactive source of having activity of the order 100 MBq. in order to carry out accurate measurement K_#beta# to K_#alpha# x-ray intensity ratios, we have develop 2#pi# geometrical configuration method : placing a target right on the surface of the ...

2003-11-01

88

Measurement of reactor tube cladding thickness by x-ray fluorescence spectrometry  

International Nuclear Information System (INIS)

An x-ray fluorescence spectrometer was designed and fabricated which nondestructively determines the thickness of aluminum cladding at small suspected thin spots in the inner or outer surface of actinide reactor tubes. The analysis method is based on the difference in absorption of actinide L/sub #alpha#/ and L/sub #beta#/ fluorescent x-rays in passing through the cladding. Calibration plots of the logarithm of the L/sub #beta#//L/sub #alpha#/ x-ray intensity ratio versus cladding thickness are linear to at least 40 mils for U-Al, U_3O_8-Al, and PuO_2-Al substrates. Accuracy and precision of the experimentally determined cladding thickness and evaluated for both uranium and plutonium substrates. Experimental thickness data are reported for 618 quality assurance analyses on six Mark 41 PuO_2-Al target tubes. An x-ray fluorescence cladding ...

1978-01-01

89

State analysis of sulfur in coal and coal fly ash by double-crystal X-ray fluorescence spectrometry  

Energy Technology Data Exchange (ETDEWEB)

Double-crystal high-resolution x-ray fluorescence spectrometry was applied to the state analysis of sulfur in coal and related fly ash. For total sulfur, a proportional relationship exists between fluorescence intensities and the analytical values obtained by the oxygen-combustion method. Two oxidation states of sulfur were identified by a least square curve fitting method, by assuming that the spectrum profile is identical for each sulfur state but the intensity and position are different. The chemical state of sulfur in coal and remaining in fly ash is discussed.

1983-01-01

90

The investigations on K and L X-ray fluorescence parameters of gold compounds  

British Library Electronic Table of Contents (United Kingdom)

The study aimed to determine the chemical effects on the K and L X-ray intensity ratios and the K and L X-ray production cross sections for gold compounds. The K shell fluorescence yields and L shell average yields were also investigated. The samples were excited by 59.5keV ?-rays from an 241Am annular radioactive source and 123.6keV ?-rays from a 57Co annular radioactive source. K and L X-rays emitted from samples were counted by an Ultra-LEGe detector with a resolution of 0.150keV at 5.9keV. The experimental values were compared with theoretical, the semi-empirical and other experimental values.

2010-01-01

91

Optimization of X-ray energy resolution from a horizontally focused single-crystal monochromator  

Energy Technology Data Exchange (ETDEWEB)

A method has been developed to optimize the energy resolution of a horizontally focusing monochromator. The method consists of determining the optimum radius of curvature of the cylindrically bent monochromator crystal by minimizing the total diffracted X-ray flux measured through an X-ray absorption foil. When measured at an absorption edge a global minimum can be identified, which corresponds to the minimum energy band accepted along the entire length of the crystal. Experimental verification of this method has been validated by comparing X-ray fluorescent scans taken for a series of crystal curvatures and by directly measuring the X-ray beam profiles at the corresponding points. The actual optical configuration and asymmetric-cut parameter of the focusing monochromator on beamline X4C at the National Synchrotron Light Source are modeled and ray tracing simulations of the optical ...

2009-02-11

92

Influence of alloying effect on X-ray fluorescence parameters of Co and Cu in CoCuAg alloy films  

British Library Electronic Table of Contents (United Kingdom)

In this study, Kb/Ka X-ray intensity ratios, Formula Not Shown , Formula Not Shown production cross-sections and K fluorescence yields of Co and Cu and Lb/La X-ray intensity ratios, Formula Not Shown , Formula Not Shown production cross-sections and Formula Not Shown average fluorescence yields of Ag in pure metals and in different alloy compositions were measured. In this study, alloying effects on the Formula Not Shown production cross-sections of Co and Cu were investigated and changes interpreted according to the rearrangement of valance state electrons and the charge transfer process between the 3d elements (Co and Cu) and Ag.

2009-01-01

93

Estimation of X-rays dose in the crystals of final thickness  

International Nuclear Information System (INIS)

A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.

94

Chandra Observations of Nuclear X-ray Emission from a Sample of Radio Sources  

CERN Document Server

We present the X-ray properties of a sample of 17 radio sources observed with the Chandra X-ray Observatory as part of a project aimed at studying the X-ray emission from their radio jets. In this paper, we concentrate on the X-ray properties of the unresolved cores. The sample includes 16 quasars (11 core-dominated and 5 lobe-dominated) in the redshift range z=0.30--1.96, and one low-power radio-galaxy at z=0.064. No diffuse X-ray emission is present around the cores of the quasars, except for the nearby low-power galaxy that has diffuse emission on a scale and with a luminosity consistent with other FRIs. No high-amplitude, short-term variability is detected within the relatively short Chandra exposures. However, 1510-089 shows low-amplitude flux changes with a timescale of $\\sim$25 minutes. The X-ray spectra of the quasar cores are ...

2003-01-01

95

DETECTION OF AN X-RAY PULSATION FOR THE GAMMA-RAY PULSAR CENTERED IN CTA 1  

International Nuclear Information System (INIS)

We report the detection of X-ray pulsations with a period of ?315.87 ms from the 2009 XMM-Newton observation for the radio-quiet ?-ray pulsar, LAT PSR J0007+7303, centered in the supernova remnant CTA 1. The detected pulsed period is consistent with the ?-ray periodicity at the same epoch found with the Fermi Gamma-ray Space Telescope. The broader sinusoidal structure in the folded light curve of the X-ray emission is dissimilar to that of the ?-ray emission, and the phase of the peak is about 0.5 shifting from the peak in the ?-ray bands, indicating that the main component of the X-rays originates from different sites of the pulsar. We conclude that the main component of the X-ray pulsation is contributed by the thermal emission from the neutron star. Although with a significantly different characteristic age, PSR J0007+7303 is similar to Geminga in emission ...

2010-12-10

96

XRF and PIXE method as trols for the element analysis of metallic glasses  

International Nuclear Information System (INIS)

The radionuclide X-ray fluorescence and particle induced X-ray emission methods were used for rapid and nondestructive analysis of metallic glasses. The methods were compared for accuracy and precision with the atomic absorption method. Some results of the analyses of Fe_xNi_8_0_-_xB_2_0 materials are briefly reviewed. The distribution of elements along the width as well as the length and a qualitative analysis of the composition of material surfaces are considered. (author).

1986-01-01

97

XRF and PIXE analysis of metallic glasses  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence and particle induced X-ray emission methods were used for a rapid and nondestructive analysis of metallic glasses. The methods are compared in accuracy and precision with the atomic absorption method. Some results of analyses of Fe_xNi_8_0_-_xB_2_0 materials are briefly reviewed. The distribution of elements along the width and length, and a qualitative analysis of the composition of material surfaces are considered. (author) 3 refs.

1987-05-01

98

X-ray spectral microanalysis of component redistribution in finely dispersed two-phase alloys  

International Nuclear Information System (INIS)

It is shown that it is necessary to take into account locality of the analysis and to introduce additional corrections for partial capture of matrix and fluorescent subexcitation by matrix during quantitative X-ray spectral microanalysis of finely dispersed materials. Cast two-phase (#alpha#+#beta#) titanium alloy VT3-1 is chosen as an investigation object.

99

Analysis of titanium and zirconium in red mud with energy dispersive x-ray spectrometry  

Energy Technology Data Exchange (ETDEWEB)

An energy dispersive x-ray fluorescence technique was used for the determination of Titanium (Ti) and Zirconium (Zr) in red mud by using a standard addition method. An annular {sup 241}Am source is employed for excitation of K shells of elements. 13 refs., 2 figs., 1 tab.

1996-11-01

100

Determination of trace elements in Syrian medicinal plants and their infusions by energy dispersive X-ray fluorescence and total reflection X-ray fluorescence spectrometry  

Energy Technology Data Exchange (ETDEWEB)

X-ray fluorescence (XRF) and total-reflection X-ray fluorescence (TXRF) techniques suited well for a multi-element determination of K, Ca, Mn, Fe, Cu, Zn, Rb, and Sr in some Syrian medicinal plant species. The accuracy and the precision of both techniques were verified by analyzing the Standard Reference Materials (SRM) peach-1547 and apple leaves-1515. A good agreement between the measured concentrations of the previously mentioned elements and the certified values were obtained with errors less than 10.7% for TXRF and 15.8% for XRF. The determination of Br was acceptable only by XRF with an error less than 24%. Furthermore, the XRF method showed a very good applicability for the determination of K, Ca, Mn, Fe, Cu, Zn, Rb, Sr, and Br in infusions of different Syrian medicinal plant species, namely anise (Anisum vulgare), licorice root (Glycyrrhiza glabra), and white wormwood (Artemisia herba-alba)

2009-07-15

102

Determination of heptacaine hydrochloride in solution using nuclear analytical methods  

Energy Technology Data Exchange (ETDEWEB)

The applicability of two nuclear analytical methods: radionuclide X-ray fluorescence analysis and radiometric titrations based on precipitate formations was studied in order to determine the heptacaine hydrochloride in solutions. The applied methods were evaluated based on the obtained sensitivity values.

1984-01-20

103

Determination of heptacaine hydrochloride in solution using nuclear analytical methods  

International Nuclear Information System (INIS)

The applicability of two nuclear analytical methods: radionuclide X-ray fluorescence analysis and radiometric titrations based on precipitate formations was studied in order to determine the heptacaine hydrochloride in solutions. The applied methods were evaluated based on the obtained sensitivity values. (author).

1984-01-01

104

Zinc determination in medicinal powders by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

X-ray fluorescence analysis was used to determine the zinc content of the ''Perilacin'' powder and the ZnO content of the ''Epiderman-pix'' powder. The characteristic Ksub(#alpha#) line of zinc was excited using a "1"4"7Pm/Mo source (10"7 s"-"1) and the molybdenum Ksub(#alpha#) line (17.47 keV). 4 to 5% Zn and 45 to 49% ZnO were determined with a NaI(Tl) scintillation detector. The radiation intensity was found to decrease with particle size. (M.K.).

1977-01-01

105

Use of X-ray fluorescence analysis in the study of archeological samples  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis (XFA) was used in the determination of the contents of metal residues in dosing plates for coin minting. XFA was also used for the determination of the strontium/calcium ratio in bone samples of different animals with the aim to obtain information on the food composition of these animals. It was found that bones of different animals can be distinguished based on the Sr/Ca ratio. No significant differences in the Sr/Ca ratio were observed in human bones of individuals from different social groups. (author). 1 fig., 5 tabs., 4 refs.

1988-09-26

106

Identification of elements in plant drugs and their water infusion using X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The present work gives preliminary results of analysis of drug mixtures (NEPHROSAL tea bag) and its water infusion. In a sample of dried drugs the elements K, Ca, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, Pb were identified, whereas in their water infusion only Ca, Mn, Zn and Sr were found. The method applied was radionuclide X-ray fluorescence analysis using a radionuclide source "1"0"9Cd, a Si/Li semiconductor detector and a multichannel analyzer Canberra 8100. (author) 6 refs.; 3 figs.

8100-01-01

107

Determination of concentration distribution of admixtures by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

A theoretical analysis is presented for the method of determining the concentration distribution of admixtures in zone melting and in the study of diffusion in melts. Continuous mode X-ray fluorescence analysis is considered. The convolution integral interpreting the analog output of the ratemeter was solved applying the mathematical apparatus of Z transformation. The feasibility of the method is tested on an example of the determination of tin distribution in tungsten. With respect to the statistical error (#delta#<1.5%), the maximum integration constant (100 s) and a very slow sample feed (0.025 mm/s) were used. The calculated transfer function reflects the total transfer function of the ratemeter and the recorder used. (M.D.).

1985-01-01

108

Determination of Mn, Fe, Cu, Zn, and Pb in particulate matter, raw and final materials of a brick factory by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence method with a Si/Li semiconductor detector and "2"3"8Pu exciting source was used in the study of Mn, Fe, Cu, Zn, and Pb content of solid emissions, raw and final materials of a brick factory. From the point of view of metal content, the working environment if the brick factory is safe for workers. (author) 2 refs.; 2 figs.; 1 tab.

1994-01-01

109

K and L x-ray production cross sections excited by 14.00--34.16 MeV #alpha#-particle beams  

International Nuclear Information System (INIS)

K and L-shell x-ray production cross sections were measured using #alpha#-particle beams of 14.00 to 34.16 MeV. The K-shell measurements ranged from Z = 20 to Z = 50 and included Ca, Sc, Ti, V, Fe, Ni, Cu, Zn, Ga, Br, Rb, Sr, Y, Mo, Ag, In, and Sn while the L-shell measurements ranged from Z = 55 to Z = 92 and included Cs, Ba, Ce, Gd, Tm, Lu, Au, Pb, Th, and U. Thin metallic foils were used for the measurements and corrections for self-attenuation were negligible. A liquid nitrogen cooled Si(Li) detector and associated pulsed optical electronics were used in detecting x-rays. Absolute cross sections with an uncertainty of +-10 percent are presented for the elements measured. Also smoothed cross sections are presented which were generated by a three term polynomial fit of the experimental data points. By use of available fluorescence yields the K-shell data were converted to ionization cross sections and ...

110

Resonant inelastic soft x-ray scattering of CdS: a two-dimensional electronic structure map approach  

Energy Technology Data Exchange (ETDEWEB)

Resonant inelastic x-ray scattering (RIXS) with soft x-rays is uniquely suited to study the elec-tronic structure of a variety of materials, but is currently limited by low (fluorescence yield) count rates. This limitation is overcome with a new high-transmission spectrometer that allows to measure soft x-ray RIXS"maps." The S L2,3 RIXS map of CdS is discussed and compared with density functional calculations. The map allows the extraction of decay channel-specific"absorp-tion spectra," giving detailed insight into the wave functions of occupied and unoccupied elec-tronic states.

2008-09-24

111

Photon-induced L-shell x-ray intensity ratio for elements with 73 #<=# Z #<=#83 in the energy range 17 #<=# E #<=# 47 keV  

International Nuclear Information System (INIS)

The L-shell x-ray intensity ratios I(L_#beta#)/I(L_#alpha#) and I(L_#gamma#)/I(L_a_l_p_h_a) for elements with 73 #<=# Z #<=# 83 have been measured at photon incident energies of 17.8, 25.8 and 46.9 keV. The emitted x-rays were measured with a Si(Li) detector system. The results for Re, Pt and Tl are being reported for the first time. A comparison is made of the experimental results with the calculated values obtained by using the theoretical x-ray emission rates, subshell ionisation cross sections, subshell fluorescence yields and Coster-Kronig transition probabilities. The experimental results are in reasonable agreement with the theoretical values. (author).

1988-01-01

112

Measurements and calculations of M-shell X-ray production in Er, Yb and Lu by 0.75-6 MeV He ions  

Energy Technology Data Exchange (ETDEWEB)

M-shell X-ray production cross sections for the light rare-earth elements of {sup 68}Er, {sup 7}Yb and {sup 71}Lu have been measured for incident {sup 4}He{sup +} ions in the energy range from 0.75 to 6 MeV. The measured X-ray production cross sections are compared to the predictions of the First Born approximation, the ECPSSR theory and the ECUSAR theory. A comparison of the ytterbium M-shell X-ray production cross sections with these theories is made for two different sets of fluorescence yields and Coster-Kronig factors that are further modified for multiple ionization.

2005-12-15

113

Total M shell X-ray production cross sections and average fluorescence yields in 11 elements from Tm to U at photon energy of 5.96 keV  

International Nuclear Information System (INIS)

Total M shell X-ray production cross section for 11 elements with 69 #<=# Z #<=# 92 have been measured using an incident photon energy of 5.96 keV. Measurements have been performed using an "5"5Fe annular source and a Si(Li) detector. Average M shell fluorescence yield at each incident photon energy has been deduced, using the experimental total M X-ray production cross section and theoretical M shell photoionization cross section. Present experimental results are compared with other experimental and theoretical values. Reasonable agreement (to within 0.3-28%) is typically obtained between present and other experimental and theoretical values.

2005-04-01

114

Improving airport explosives detection  

Energy Technology Data Exchange (ETDEWEB)

ORNL has developed the technology to detect hidden explosives in luggage using X ray and neutron detection devices. The Federal Aviation Administration has ordered the airlines to buy and install Thermal Neutron Analysis (TNA) units. The combined pulsed-neutron and X-ray interrogation inspection (CPNX) system developed at ORNL uses less radioactive materials as well as being more sensitive to weapons, electronic devices and plastic explosives.

1990-01-01

115

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons ...

2007-01-01

116

A Remarkable Low-Mass X-ray Binary within 0.1 pc of the Galactic Center  

CERN Document Server

Recent X-ray and radio observations have identified a transient low-mass X-ray binary (LMXB) located only 0.1 pc in projection from the Galactic center, CXOGC J174540.0-290031. In this paper, we report the detailed analysis of X-ray and infrared observations of the transient and its surroundings. Chandra bservations detect the source at a flux of F_X = 2e-12 erg cm^-2 s^-1 (2-8 keV). After accounting for absorption both in the interstellar medium and in material local to the source, the implied luminosity of the source is only L_X = 4e34 erg/s (2-8 keV; D=8 kpc). However, the diffuse X-ray emission near the source also brightened by a factor of 2. The enhanced diffuse X-ray emission lies on top of a known ridge of dust and ionized gas that is visible infrared images. We interpret the X-ray emission as scattered flux from the outburst, and ...

2005-01-01

117

Theoretical transition energies, lifetimes and fluorescence yields of multiply ionized silicon  

Energy Technology Data Exchange (ETDEWEB)

Theoretical x-ray transition energies, lifetimes and partial multiplet fluorescence yields are presented for all spectroscopic terms of electron configurations with a single K-shell vacancy and varying number of electrons in the L-shell and M/sub 1/-subshell for multiply-ionized silicon. 9 tables.

1982-01-01

118

State analysis of sulfur in coal and coal fly ash by double-crystal X-ray fluorescence spectrometry  

Energy Technology Data Exchange (ETDEWEB)

Double-crystal high-resolution X-ray fluorescence spectrometry was applied to the state analysis of sulfur in coal and related fly ash. For total sulfur, a proportional relationship exists between fluorescence intensities and the analytical values obtained by the oxygen-combustion method. Two oxidation states of sulfur were identified by a least square curve fitting method, by assuming that the spectrum profile is identical for each sulfur state but the intensity and the position are different. Sulfur in coal mainly consists of S/sup 2 -/, whereas that in coal fly ash mainly consists of S/sup 6 +/. As much as 0.04-0.08% of S/sup 2 -/ remains in fly ash.

1983-01-01

119

Measurement of the L sub 2 - L sub 3 Coster-Kronig transition probability in Tm( Z =69)  

Energy Technology Data Exchange (ETDEWEB)

The {ital L}{sub 2}-{ital L}{sub 3} Coster-Kronig transition probability ({ital f}{sub 23}) in Tm was measured by multiparameter {ital K} versus {ital L} x-ray coincidence techniques. The Tm x rays were obtained from a radioactive source of {sup 169}Yb and were detected with cooled germanium and silicon detectors of high-energy resolution. Corrections were applied for the contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak and for the contribution of unresolved {ital L}{eta} x rays to the {ital L}{alpha}{sub 1,2} x-ray peak. The contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak was determined solely from the results of the coincidence measurements ...

1989-11-01

120

Measurement of the L sub 2 - L sub 3 Coster-Kronig transition probability in Tm( Z =69)  

Science.gov (United States)

The {ital L}{sub 2}-{ital L}{sub 3} Coster-Kronig transition probability ({ital f}{sub 23}) in Tm was measured by multiparameter {ital K} versus {ital L} x-ray coincidence techniques. The Tm x rays were obtained from a radioactive source of {sup 169}Yb and were detected with cooled germanium and silicon detectors of high-energy resolution. Corrections were applied for the contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak and for the contribution of unresolved {ital L}{eta} x rays to the {ital L}{alpha}{sub 1,2} x-ray peak. The contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak was determined solely from the results of the coincidence measurements ...

1989-11-01

121

Theoretical modelling of X-ray fluorescence signals for different lunar compositions and dependence on solar activity  

British Library Electronic Table of Contents (United Kingdom)

We present a forward modelling technique for calculating the surface X-ray spectra for a variety of lunar terrains. Our calculations considered variations in solar fluxes from solar quiescent condition to large flare activity (M1 flare), and expected elemental concentrations in the target, as well as yield, instrumental, and viewing geometry parameters for X-ray induced fluorescence from the lunar surface. Additionally, we present estimates of anticipated XRF signals from prominent Ka lines observable by a collimated 14cm2 X-ray detector from a 100km lunar orbit with 20km spatial resolution. Our results show that Mg, Al and Si characteristic Ka lines can be observed for all solar conditions. The Ca Ka lines line can be differentiated from a fixed background during more energetic solar cond...

2010-01-01

122

Study of metal concentration in sediment of some springs of Lebanon  

International Nuclear Information System (INIS)

Full text.Surficial sediment samples were collected from seventeen springs distributed all over Lebanon (east, west, north and south). Concentrations of metals Ca, Fe, Mn, Ni, Cu, Cr, Zn and Pb were determined by energy dispersive x-ray fluorescence technique. Irradiation was done by the radioisotope source Cd-109 and the detection by an EG and G Si(Li) detector. These analysis was done in attempt to assess the impact of anthropogenic sources on ground water quality. Metals concentration in sediment were found to be (Ca:0.05-47%, Fe:0.24-4.2%, Cr:

1999-11-02

123

High sensitivity detection and characterization of the chemical state of trace element contamination on silicon wafers  

CERN Document Server

Increasing the speed and complexity of semiconductor integrated circuits requires advanced processes that put extreme constraints on the level of metal contamination allowed on the surfaces of silicon wafers. Such contamination degrades the performance of the ultrathin SiO sub 2 gate dielectrics that form the heart of the individual transistors. Ultimately, reliability and yield are reduced to levels that must be improved before new processes can be put into production. It should be noted that much of this metal contamination occurs during the wet chemical etching and rinsing steps required for the manufacture of integrated circuits and industry is actively developing new processes that have already brought the metal contamination to levels beyond the measurement capabilities of conventional analytical techniques. The measurement of these extremely low contamination levels has required the use of synchrotron radiation total reflection X-ray ...

2003-01-01

124

Characterisation and use of biomass fly ash in cement-based materials  

British Library Electronic Table of Contents (United Kingdom)

This paper presents results about the characterisation of the biomass fly ashes sourced from a thermal power plant and from a co-generation power plant located in Portugal, and the study of new cement formulations incorporated with the biomass fly ashes. The study includes a comparative analysis of the phase formation, setting and mechanical behaviour of the new cement-fly ash formulations based on these biomass fly ashes. Techniques such as X-ray diffraction (XRD), X-ray fluorescence spectroscopy (XRF), thermal gravimetric and differential thermal analysis (TG/DTA), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and environmental scanning electron spectroscopy (ESEM) were used to determine the structure and composition of the formulations. Fly ash F1 from the t...

2009-01-01

125

X-ray exposure in the teaching of science at junior and senior high schools  

Energy Technology Data Exchange (ETDEWEB)

A significant amount of X-rays were detected as a leakage from some of the Crooke`s tubes which were used in the teaching of science at junior and senior high schools in Japan. We measured the leaked dose of X-rays from the Crooke`s tubes with ionizing chambers, film badges and TLDs. The maximum leaked dose at 5cm distance from those tubes was estimated 143mSv/h. The effective energy of leaked X-rays was 19.3keV. The maximum dose of students exposed during the teaching of science were estimated 0.15mSv per experiment, which exceeded the value recommended in the ICRP publication 36. (author)

1995-10-01

126

What can we learn about extragalactic radio jets from X-ray data?  

CERN Document Server

We review the current status of resolved X-ray emission associated with extragalactic radio jets and hotspots. The primary question for any particular jet is to decide if the X-rays come from the synchrotron process or from inverse Compton scattering. There is considerable evidence supporting synchrotron emission for knots in the jets of FRI galaxies. For FRII terminal hotspots detected in the X-ray band, synchrotron self-Compton emission continues to provide viable models with one possible exception (so far). Inverse Compton scattering on photons of the cosmic microwave background is indicated for a few powerful jets, and is expected to be an important contributor if not the dominating mechanism for higher redshift objects. The application of a model generally yields physical parameters and in many cases, these include the Doppler boosting factor.

2003-01-01

127

K_#beta#/K_#alpha#X-ray intensity ratio in the region of 15#<=#Z#<=#22  

International Nuclear Information System (INIS)

The X-ray intensity ratio K_#beta#/K_#alpha# has been measured by using a 10 mCi "5"5Fe source (Mn K X-rays) and high resolution Si(Li) detector system coupled to a computer-controlled multichannel analyzer over the range of 15#<=#Z#<=#22. Correction have been made to the measured relative intensities (K_#alpha# and K_#beta# X-rays) for self-absorption in the sample, air, Be-window absorption and detection efficiency. The results are compared with those of other experiments and with the Scofield calculations. (author) 13 refs.; 3 figs.; 2 tabs.

1994-01-01

128

Biogenic iron oxyhydroxide formation at mid-ocean ridge hydrothermal vents: Juan de Fuca Ridge  

Energy Technology Data Exchange (ETDEWEB)

Here we examine Fe speciation within Fe-encrusted biofilms formed during 2-month seafloor incubations of sulfide mineral assemblages at the Main Endeavor Segment of the Juan de Fuca Ridge. The biofilms were distributed heterogeneously across the surface of the incubated sulfide and composed primarily of particles with a twisted stalk morphology resembling those produced by some aerobic Fe-oxidizing microorganisms. Our objectives were to determine the form of biofilm-associated Fe, and identify the sulfide minerals associated with microbial growth. We used micro-focused synchrotron-radiation X-ray fluorescence mapping (mu XRF), X-ray absorption spectroscopy (mu EXAFS), and X-ray diffraction (mu XRD) in conjunction with focused ion beam (FIB) sectioning, and highresolution transmission electron microscopy (HRTEM). The chemical and mineralogical composition of an Fe-encrusted biofilm was queried at ...

2008-05-22

129

M shell x-ray emission in Pb, Th and U due to L_3 to M sub shell transfer of vacancies  

International Nuclear Information System (INIS)

M shell x-ray production cross sections in thick targets of Pb, Th and U by K x-rays of Rb, Nb and Mo respectively have been measured. As the incident K x-ray energies are above the L_3 edge but below L_2 edge energies of the respective target elements under reference, the M x-rays are produced not only due to direct interaction of incident photons with M shell electrons but also due to the shift of the L_3 subshell vacancies to the M shell. The experiment has been performed using a double reflection geometrical setup with a 1 Curie"2"4"1Am gamma ray source and a Si (Li) x-ray spectrometer. The measured values have been compared with those calculated using known values of M and L_3 subshell photoionisation cross sections and fluorescence yields etc., wherever possible. The component of the percentage contribution due to shift of L_3 subshell vacancies to M shell ...

130

X-ray fluorescence in research on Czech cultural monuments  

Energy Technology Data Exchange (ETDEWEB)

Radionuclide X-ray fluorescence analysis (RXRFA), as a non-destructive method, relatively simple and allowing measurements to be carried out in situ, is an excellent tool in research on various objects of art. A range of artefacts have been investigated by our laboratory, in part for the purposes of history of art and in part as a basis for restoration works - medieval frescoes in some Czech castles and churches, metal sculptures and objects of applied art, paints and inks of old manuscripts, paintings. Some of these are among the most valuable monuments in the Czech cultural heritage. The contribution of the results of the tests to the investigation of their 'life story' and, in some cases, to their conservation, is not negligible. Later additions and repairs can be recognised, and materials and technologies that are close to their historic counterparts can be used in restoration work.

2004-01-01

131

X-ray fluorescence in research on Czech cultural monuments  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis (RXRFA), as a non-destructive method, relatively simple and allowing measurements to be carried out in situ, is an excellent tool in research on various objects of art. A range of artefacts have been investigated by our laboratory, in part for the purposes of history of art and in part as a basis for restoration works - medieval frescoes in some Czech castles and churches, metal sculptures and objects of applied art, paints and inks of old manuscripts, paintings. Some of these are among the most valuable monuments in the Czech cultural heritage. The contribution of the results of the tests to the investigation of their 'life story' and, in some cases, to their conservation, is not negligible. Later additions and repairs can be recognised, and materials and technologies that are close to their historic counterparts can be used in restoration work.

2004-01-01

132

Spatial distribution of arsenic and heavy metals in willow roots from a contaminated floodplain soil measured by X-ray fluorescence spectroscopy  

British Library Electronic Table of Contents (United Kingdom)

Under changing redox conditions some plants create plaques at their root surface, which may affect the mobility and uptake of As and heavy metals but it is unknown to what extent this also holds true for willows in contaminated floodplain soils. Therefore, willow roots were sampled from a phytoremediation trial in the contaminated floodplain of the river Elbe (Germany), cryofixed, freeze-dried, and cross sections were mapped for the distribution of As, Ca, Cu, Fe, K, Mn, Ni, S and Zn by synchrotron based X-ray fluorescence spectroscopy. The elements Ca, Cu, Ni, S and Zn were concentrated in the aerenchymatic tissue, and not associated with Fe and Mn. Mixed Fe-Mn plaques covered the surface of the willow roots and As was accumulated in these plaques. The observed association pattern between...

2011-01-01

133

Determination of selected elements by radionuclide X-ray fluorescence analysis after the separation on different kinds of sorption materials  

International Nuclear Information System (INIS)

This paper aimed to the evaluation of different kinds of sorbent material preparation and to the evaluation of their characteristics at different pH conditions by X-ray fluorescence analysis. This method is suitable for identification and determination of elements in samples of different character, state and origin because it is a polycomponent, non-destructive, fast and simple analytical method. Moreover, it allows timeadvantageous and reliable measurements. This paper studies problems concerning the determination of some selected elements (Mn, Fe, Ni, Cu, Zn, Pb) in pharmaceutical samples of sodium chloride in the solid state as well as in its solution by sorption on chelating extraction membrane 3M Empore"T"M and on the strongly acidic ion-exchanger Dowex 50Wx8. Conditions for the most effective sorption of determined elements are also interpreted. (author)

2008-03-01

134

Determination of selected elements by radionuclide X-ray fluorescence analysis after the separation on different kinds of sorption materials  

British Library Electronic Table of Contents (United Kingdom)

This paper aimed to the evaluation of different kinds of sorbent material preparation and to the evaluation of their characteristics at different pH conditions by X-ray fluorescence analysis. This method is suitable for identification and determination of elements in samples of different character, state and origin because it is a polycomponent, non-destructive, fast and simple analytical method. Moreover, it allows time-advantageous and reliable measurements. This paper studies problems concerning the determination of some selected elements (Mn, Fe, Ni, Cu, Zn, Pb) in pharmaceutical samples of sodium chloride in the solid state as well as in its solution by sorption on chelating extraction membrane 3M Empore? and on the strongly acidic ion-exchanger Dowex 50Wx8. Conditions for the most ef...

2008-01-01

135

X-ray, Optical, and Radio Observations of SN 1999em and SN 1998S  

CERN Document Server

Observations of the Type II-P (plateau) Supernova (SN) 1999em and Type IIn (narrow emission line) SN 1998S have enabled estimation of the profile of the SN ejecta, the structure of the circumstellar medium (CSM) established by the pre-SN stellar wind, and the nature of the shock interaction. SN 1999em is the first and only Type II-P detected at both X-ray and radio wavelengths. It is the least radio luminous and one of the least X-ray luminous SN ever detected (except for the unusual and very close SN 1987A). The Chandra X-ray data indicate non-radiative interaction of SN ejecta with a power-law density profile (rho \\propto r^{-n} with n ~ 7) with a pre-SN wind with a low mass loss rate of ~2 \\times 10^{-6} Msun/yr for a wind velocity of 10 km/sec, in close agreement with radio mass-loss rate estimates. The Chandra data show an unexpected, temporary rise in the 0.4--2.0 keV ...

2001-01-01

136

Detection and Analysis of Tumor Fluorescence Using a Two-Photon Optical Fiber Probe  

UK PubMed Central (United Kingdom)

The utility of a two-photon optical fiber fluorescence probe (TPOFF) for sensing and quantifying tumor fluorescent signals was tested in vivo. Xenograft tumors were developed in athymic mice using MCA207...Full Text Available

2004-06-01

137

Valence electronic structure of Ni in Ni-Si alloys from relative K X-ray intensity studies  

Energy Technology Data Exchange (ETDEWEB)

The K{beta}-to-K{alpha} X-ray intensity ratio of Ni in Ni{sub 3}Si, Ni{sub 2}Si and NiSi has been determined by energy dispersive X-ray fluorescence technique. It is found that the intensity ratio of Ni decreases from pure Ni to Ni{sub 2}Si and then increases from Ni{sub 2}Si to NiSi, in good agreement with the electronic structure calculations cited in the literature. We have also performed band structure calculations for pure Ni in various atomic configurations by means of linear muffin-tin orbital method and used this data with the normalized theoretical intensity ratios cited in the literature to estimate the 3d-occupation numbers of Ni in Ni-Si alloys. It is emphasized that investigation of alloying effect in terms of X-ray intensity ratios should be carried out for the stoichiometric alloys in order to make reliable and quantitative comparisons between theory and experiment in transition metal ...

2007-02-15

138

Phase, residual stress, and texture in triode-sputtered tantalum coatings on steel. Final report  

Energy Technology Data Exchange (ETDEWEB)

This work analyzes the unoptimized prototype triode-sputtered, 150 microns thick tantalum coatings deposited with a 2.5 microns niobium underlayer on the bore of a large-diameter A723 steel cylinder. The coating was deposited for wear and erosion protection by Pacific Northwest National Laboratory. The phase determination was based on X ray diffraction analysis, wavelength dispersive X ray fluorescence analysis, energy dispersive X ray analysis, and hardness and electrical resistivity measurements. Both X ray diffraction and radius-of- curvature methods were used to determine residual stresses. A locally developed high-resolution pole figure technique was used to perform texture analysis. The post-firing, debonded coating showed alpha-tantalum, preferred 110 orientation, high surface stresses, ...

1998-07-01

139

Measurement of relative L X-ray intensity ratio following radioactive decay and photoionization  

International Nuclear Information System (INIS)

The measurements of the L X-ray intensity ratio I(L?)/I(L?), I(L?)/I(L?), I(L?)/I(L?), I(L?)/I(L?) and I(L?)/I(L?) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV ?-rays from a filtered radioisotope 241Am was used, and by the radioactive decay of 160Tb, 160Er, 173Lu, 182Re, 201Tl, 203Pb and 207Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L?/L?), I(L?/L?), I(L?/L?), I(L?/L?) and I(L?/L?) intensity ratios were calculated using theoretically tabulated values of subshell photoionization cross-section, fluorescence yield, fractional X-ray emission rates, Coster-Kronig transition probabilities. It was observed that present values agree with previous theoretical and other available ...

2008-05-22

140

Nanofocusing refractive X-ray lenses  

Energy Technology Data Exchange (ETDEWEB)

This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is ...

2010-02-05

141

Unique Properties of Thermally Tailored Copper: Magnetically Active Regions and Anomalous X-ray Fluorescence Emissions  

UK PubMed Central (United Kingdom)

When high-purity copper (≥99.98%wt) is melted, held in its liquid state for a few hours with iterative thermal cycling, then allowed to resolidify, the ingot surface is found to have...Full Text Available

2009-12-24

142

Standard deviation of measurement results in x-ray fluorescence spectrometry  

International Nuclear Information System (INIS)

The standard deviation of measurement results of a given element in XRF spectrometry depends on three factors: concentration and concentration region, atomic number and matrix. The effects of these factors were investigated by an XRF instrument type ARL 72.000 for aluminium metal, bauxite-red mud and aluminium using computerized data processing. A comparison of linear and nonlinear relation between concentration and the result of XRF analysis was made for the determination of standard deviation. (R.P.).

1984-11-13

143

Radionuclide X-ray fluorescence analysis of drinking water using preconcentration of trace metals on chelating cellulose exchanger ostsorb-oxin  

International Nuclear Information System (INIS)

Determination of Cr, Fe, Cu, Zn and Pb in drinking water preconcentrated on a chelating ion exchanger of Czechoslovak production is described. The analytical system consisted of a radionuclide source "2"3"8Pu, a Si/Li semiconductor detector and a multichannel analyzer. Results are compared with trehshold limit values recommended for drinking water. (author) 9 refs.; 2 figs.

1992-04-01

144

Radioanalytical chemistry. Vol. 2  

International Nuclear Information System (INIS)

This volume of the monograph covers the following topics: activation analysis, non-activation interaction analysis (elastic scattering of charged particles, absorption and backscattering of beta radiation and photons, radionuclide X-ray fluorescence analysis, thermalization, scattering and absorption of neutrons, use of ionization caused by nuclear radiation, use of ionization by alpha or beta radiation for the measurement of pressure, density and flow rate of gases), and automation in radioanalytical chemistry. (P.A.).

1989-01-01

145

Determination of the Sr/Ca ratio in bones by XRFA  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis was used for the determination of Sr/Ca ratio in bones to test the influence of a diet on this ratio. Significant differences were observed for Sr/Ca ratio in bones of various animals. Only small differences in the Ca/Sr ratio were observed for the samples of various prehistoric human bones. (author) 4 refs.; 4 tabs.

1989-11-01

146

Determination of heavy metals in welders' working environment using nuclear analytical methods  

International Nuclear Information System (INIS)

Technological processes of welding are significant sources of pollution in the working area. Evaluation of chemical quality of working area was made by means of radionuclide x-ray fluorescence analysis and activation analysis with fast neutrons. Welding aerosols were sampled by filtration method on Synpor 4 membrane ultra-filters. For selected types of welding filter metals, determination of heavy metals in aerosols was performed. (author).

1985-01-01

147

Determination of heavy metals in welders' working environment using nuclear analytical methods  

Energy Technology Data Exchange (ETDEWEB)

Technological processes of welding are significant sources of pollution in the working area. Evaluation of chemical quality of working area was made by means of radionuclide x-ray fluorescence analysis and activation analysis with fast neutrons. Welding aerosols were sampled by filtration method on Synpor 4 membrane ultra-filters. For selected types of welding filter metals, determination of heavy metals in aerosols was performed.

1985-01-03

148

Determination of heavy metals in industrial wastewaters and their influence on activated sludge biocenose  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence method with a Si/Li semiconductor detector and "2"3"8Pu exciting source was used in the determination of Cr, Fe, Ni, Cu, and Zn content in industrial wastewaters. Simultaneously, the effects of the wastewaters on activated sludge biocenose were evaluated. (author) 6 refs.; 1 fig.; 1 tab.

1994-03-01

149

Determination of Mg, Al, Si, Cl and K in some medicinal plants by NAA and REA methods  

Energy Technology Data Exchange (ETDEWEB)

Trace elements have been determined in biological samples including pepperwort, thyme, plantain, blessed thistle and common comfrey as well as cabbage leaves and milk powder. Concentrations of Al, Si, and Cl have been determined by fast neutron activation analysis while, in the case of Mg-, K, and Cl the X-ray fluorescence method was used.

1982-07-26

151

Contribution to the sample preparation in the radionuclide X-ray fluorescence analysis of hair  

International Nuclear Information System (INIS)

Methods of sample treatment in XRF analysis of hair are studied in view of the effect on analytical results. A new method is proposed based on the incomplete ashing of hair followed by pellet preparation. Its suitability is estimated on the XRF analysis of real hair samples collected from 4 healthy adults. (author) 12 refs.; 4 figs.; 1 tab.

1989-03-01

152

Application of isotope-excitation x-ray fluorescence (XRF) analysis for aluminium production  

International Nuclear Information System (INIS)

An energy sensitive Si(Li) detector XRF analyzer built by ATOMKI, Hungary, has been applied for various analytical purposes in alumina production at the Almasfuezitoe Alumina Company, Hungary. Specifically, the CaO content in red mud was determined by the new XRF technique using isotope excitation sources. The analysis of other components is under way. (R.P.).

153

A simple system of instruments for radionuclide X-ray fluorescence analysis in nonferrous metallurgy  

International Nuclear Information System (INIS)

Proceeding from commercially available instruments, a simple measuring system has been established, which renders possible fast and simple discontinuous analysis of individual elements. This measuring system is described, giving some examples of utilization in nonferrous metallurgy (mining, ore dressing, metallurgical treatment), and specific details, such as error of measurement, ranges of measurement and limits of utilization. (author).

1979-01-01

154

2. Nuclear analytical methods and environmental protection  

International Nuclear Information System (INIS)

The first step in the protection of the environment is the control of pollutant level in the components of the environment. The application is compared of radionuclide X-ray fluorescence analysis (RXFA) used for this purpose with polarographic and nuclear analytical techniques. The advantage of RXFA is its high sensitivity and selectivity, its low time and cost exactingness. The origins and development of RXFA are described. (Ha).

1983-12-01

155

Study of X-ray filter and peak kilovoltage in Fuji computed radiography in regard to the detection of simulated pulmonary nodules  

Energy Technology Data Exchange (ETDEWEB)

To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that (1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; (2) ...

1994-10-01

156

Study of X-ray filter and peak kilovoltage in Fuji computed radiography in regard to the detection of simulated pulmonary nodules  

International Nuclear Information System (INIS)

To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that 1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; 2) ...

1994-01-01

157

X-ray scattering signatures of {beta}-thalassemia  

Energy Technology Data Exchange (ETDEWEB)

X-ray scattering from lyophilized proteins or protein-rich samples is characterized by the presence of two characteristic broad peaks at scattering angles equivalent to momentum transfer values of 0.27 and 0.6 nm{sup -1}, respectively. These peaks arise from the interference of coherently scattered photons. Once the conformation of a protein is changed, these two peaks reflect such change with considerable sensitivity. The present work examines the possibility of characterizing the most common cause of hemolytic anaemia in Egypt and many Mediterranean countries; {beta}-thalassemia, from its X-ray scattering profile. This disease emerges from a genetic defect causing reduced rate in the synthesis of one of the globin chains that make up hemoglobin. As a result, structurally abnormal hemoglobin molecules are formed. In order to detect such molecular disorder, hemoglobin samples of {beta}-thalassemia patients are collected, ...

2009-08-11

158

The intriguing nature of the high energy gamma ray source XSSJ12270-4859  

CERN Document Server

The nature of the hard X-ray source XSSJ12270-4859 is still unclear though it was claimed to be a magnetic Cataclysmic Variable. We here present a broad-band X-ray and gamma ray study based on a recent XMM-Newton observation and archival INTEGRAL and RXTE data. From the Fermi/LAT 1-year point source catalogue, we tentatively associate XSSJ12270-4859 with 1FGLJ1227.9-4852, a source of high energy gamma rays with emission up to 10GeV. We complement the study with UV photometry from XMM-Newton and ground-based optical and near-IR photometry. The X-ray emission is highly variable showing flares and intensity dips. The X-ray flares consist of flare-dip pairs. Flares are also detected in the UV range but not the dips. Aperiodic dipping behaviour is also observed during X-ray quiescence but not in the UV. The 0.2-100keV spectrum is featureless and described by a power ...

2010-01-01

159

The infrared-dominated jet of 3C401  

CERN Document Server

We present a Hubble Space Telescope image of the FRII radio galaxy 3C 401, obtained at 1.6 microns with the NICMOS camera in which we identify the infrared counterpart of the brightest region of the radio jet. The jet has a complex radio structure and brightens where bending occurs, most likely as a result of relativistic beaming. We analyze archival data in the radio, optical and X-ray bands and we derive its spectral energy distribution. Differently from all of the previously known optical extragalactic jets, the jet in 3C401 is not detected in the X-rays even in a long 48ksec X-ray Chandra exposure and the infrared emission dominates the overall SED. We propose that the dominant radiation mechanism of this jet is synchrotron. The low X-ray emission is then caused by two different effects: i) the lack of any strong external photon field and ii) the shape of the electron ...

2005-01-01

160

Spherically bent crystal spectroscopy in laser-produced plasma  

International Nuclear Information System (INIS)

A curved crystal X-ray spectrographs of reflection type spherical geometry was required based on the Johann scheme. Due to their high efficiency and resolution, X-ray spectrographs of focusing spectrograph spatial resolution are suitable for detecting weak X-ray spectra in spectrometers for laser fusion research. Spherically bent mica crystal with a radius of curvature of 380 mm was used in the spectrometer. The Bragg angle of the crystal analyzer was 51 degree. The image plate was employed to obtain high spatial resolution and a narrow spectral band width, with an effective area of 30 mm x 80 mm. The designed optical path of the X-ray spectrometer beam was 980 mm long from the source to the crystal and the detector. The first experiment was carried out at the 20 J energy laser facility of Research Center of Laser Fusion, China Academy of Engineering Physics. ...

2008-02-01

161

Theoretical considerations for X-ray phase contrast mammography by Thomson source  

Energy Technology Data Exchange (ETDEWEB)

The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase imaging with respect to standard absorption imaging, in the ...

2009-09-01

162

The X-ray Halo of G21.5-0.9  

CERN Document Server

The emission of the plerion G21.5-0.9 appears more extended in X rays than in radio. This is an unexpected result because it would imply that short-lived X-ray electrons may reach distances even larger than radio electrons. Applying an empirical relationship between dust scattering optical depth and photoelectric column density, the measured column density leads to a large optical depth at 1 keV, of about 1. Therefore we investigate the hypothesis that the detected halo be an effect of dust scattering, re-analyzing an Cal/PV XMM-Newton observation of G21.5-0.9 and critically examining it in terms of a dust scattering model. We also present a spectral analysis of a prominent extended feature in the northern sector of the halo.

2003-01-01

163

M-shell x-ray production by 0.6--4.0-MeV protons in ten elements from hafnium to thorium  

International Nuclear Information System (INIS)

M-shell x-ray production cross sections for selected heavy elements, namely, _7_2Hf, _7_3Ta, _7_4W, _7_5Re, _7_6Os, _7_7Ir, _7_8Pt, _7_9Au, _8_3Bi, and _9_0Th, were measured for protons of energy 0.6--4.0 MeV. The experimental results are compared with the predictions of the first Born and semiclassical approximations for M-shell ionization; these data are also compared with the theory that accounts for the projectile's energy loss and Coulomb deflection as well as for the target's M-shell electron perturbed stationary state and relativistic nature (ECPSSR). Generally, fair agreement between the data and the ECPSSR theory is found. Some systematical discrepancies observed for the lightest elements (Hf, Ta, and W) are explained as possible ambiguities in the M-shell Coster-Kronig factors and fluorescence yields, which were used to convert theoretical M-subshell ionization cross sections to the total M-x-ray production cross ...

164

Computed radiography in X-ray examination of stomach. Evaluation by phantom experiments and clinical studies  

Energy Technology Data Exchange (ETDEWEB)

The usefulness and clinical applicability of computed radiography(FCR) in X-ray examination of the stomach were evaluated in comparison with film-screen (FS) radiography by both phantom experiments and clinical studies. Receiver operating characteristic (ROC) curve analysis consisting of 25 normal and 25 artificially created simulated lesions on an orginally created Styrofoam phantom showed no difference in lesion detectability between FCR and FS radiography. Both were also equal in evaluation of the internal structure and margin of the 25 lesions by visual ranking. ROC curve analysis of clinical cases was performed in 30 cases, 20 normal and 10 abnormal, while evaluation by visual ranking was performed on 18 lesions. There was no significant difference between FCR and FS radiography either with ROC curve analysis or visual ranking, although the variations were somewhat greater in the clinical cases than in the phantom studies. I conclude that ...

1995-08-01

165

Computed radiography in X-ray examination of stomach. Evaluation by phantom experiments and clinical studies  

International Nuclear Information System (INIS)

The usefulness and clinical applicability of computed radiography(FCR) in X-ray examination of the stomach were evaluated in comparison with film-screen (FS) radiography by both phantom experiments and clinical studies. Receiver operating characteristic (ROC) curve analysis consisting of 25 normal and 25 artificially created simulated lesions on an orginally created Styrofoam phantom showed no difference in lesion detectability between FCR and FS radiography. Both were also equal in evaluation of the internal structure and margin of the 25 lesions by visual ranking. ROC curve analysis of clinical cases was performed in 30 cases, 20 normal and 10 abnormal, while evaluation by visual ranking was performed on 18 lesions. There was no significant difference between FCR and FS radiography either with ROC curve analysis or visual ranking, although the variations were somewhat greater in the clinical cases than in the phantom studies. I conclude that ...

1995-01-01

167

Depth-profiling of vertical sidewall nanolayers on structured wafers by grazing incidence X-ray flourescence  

British Library Electronic Table of Contents (United Kingdom)

The Physikalisch-Technische Bundesanstalt (PTB), Germany's national metrology institute, developed an alignment strategy to specify elemental depth profiling in vertical sidewall layers on structured wafers. For this purpose, PTB's irradiation chamber for 200?mm and 300?mm silicon wafers was used to combine total-reflection X-ray fluorescence (TXRF) and grazing incidence XRF (GIXRF) techniques by employing monochromatized undulator radiation of the BESSY II electron storage ring. 3-D test structures were fabricated to develop an optimal alignment strategy allowing for depth profiling in such nanolayers. The test structures consisted of silicon bars with widths/spacings either in the ?m or in the nm range. In order to be able to differentiate the sidewalls more easily from the remainder of ...

2008-01-01

168

Analysis of the archaeological pieces with the PIXE technique; Analisis de piezas arqueologicas con la tecnica PIXE  

Energy Technology Data Exchange (ETDEWEB)

The handling of physical-nuclear techniques for the analysis of archaeological pieces it was carried out by first time in 1956 by the doctors Oppenheimer and Dodsom (in the United States); who wrote about the wide utilities of the neutron activation analysis (NAA), this technique requires of a nuclear reactor that could be considered like one a factory of thermal neutrons necessary to carry out this analysis. The first experiments in that were applied the NAA were on ceramic coming from the Mediterranean, in those that the relationships of the elements of sodium and manganese were determined to know their elementary composition and to identify the origin of their manufacture. Later on other study techniques were applied in archaeological materials, as the X-ray fluorescence, Moessbauer spectroscopy, scanning electron microscopy, PIXE analysis (particle induced x-ray emission), among other, this last is the matter that we ...

2005-07-01

169

Color Fluorescence Ratio for Detection of Bronchial Dysplasia and Carcinoma In situ  

UK PubMed Central (United Kingdom)

BackgroundAutofluorescence bronchoscopy is more sensitive than conventional bronchoscopy for detecting early airway mucosal lesions. Decreased specificity can lead...Full Text Available

2009-07-15

170

How epitaxial are Pd/sub 2/Si-Si interfaces  

Energy Technology Data Exchange (ETDEWEB)

Pd/sub 2/Si layers produced by evaporation or sputtering onto silicon substrates were examined by high resolution electron microscopy, microdiffraction, X-ray, energy loss and Auger spectroscopy. The Si-Pd/sub 2/Si interfaces produced by evaporation were in all cases rougher and more polycrystalline than those produced by sputtering. X-ray microanalysis showed the predictable variation in palladium distribution across the interface but quantification did not produce the expected palladium-to-silicon ratios, primarily because of probe broadening and X-ray-induced fluorescence. Energy loss spectra showed plasmon energy shifts and changes in Si L edge shape due to bond formation with palladium. Auger data provided evidence for a small amount of oxygen at the Si-Pd/sub 2/Si interface. Electrical measurements of the ideality factor for Schottky barriers made from the materials produced higher values for the ...

1983-06-17

171

Swift panchromatic observations of the bright gamma-ray burst GRB050525a  

CERN Document Server

The bright gamma-ray burst GRB050525a has been detected with the Swift observatory, providing unique multiwavelength coverage from the very earliest phases of the burst. The X-ray and optical/UV afterglow decay light curves both exhibit a steeper slope ~0.15 days after the burst, indicative of a jet break. The timing of the jet break combined with the total gamma-ray energy of the burst constrains the opening angle of the jet to be 2.5 degrees. We derive an empirical `time-lag' redshift from the BAT data of z_hat = 0.69 +/- 0.02, in good agreement with the spectroscopic redshift of 0.61. Prior to the jet break, the X-ray data can be modelled by a simple power law with index alpha = -1.2. However after 300s the X-ray flux brightens by about 30% compared to the power-law fit. The optical/UV data have a more complex decay, with evidence of a rapidly falling reverse shock component that dominates in the ...

2006-01-01

172

M X-ray production in Nd, Gd, Ho and Lu by 1-6 MeV lithium ions  

Energy Technology Data Exchange (ETDEWEB)

M-shell X-rays of the rare-earth elements {sub 60}Nd, {sub 64}Gd, {sub 67}Ho and {sub 71}Lu were measured for lithium ion bombardment in the energy range 1.0-6.0 MeV. The M-shell X-rays with energies of 0.978-1.631 keV were detected with a LINK analytical detector. The efficiency of the detector was determined by using the known atomic-field bremsstrahlung cross-sections from low energy electron beams and K-shell X-ray measurements with light projectiles. The measured cross-sections are compared to the predictions of the first Born approximation and the ECPSSR (energy loss and Coulomb deflection effects, perturbed stationary state approximation with relativistic correction) theories. The best theoretical description of the present data is given by the ECPSSR theory, even though the discrepancy between data and theory is increasing at higher projectile energies.

2004-06-01

173

An X-ray source population study of the Andromeda galaxy M 31  

CERN Document Server

XMM-Newton EPIC observations reveal the population of X-ray sources of the bright Local Group spiral galaxy M 31, a low-star-formation-rate galaxy like the Milky Way, down to a 0.2-4.5 keV luminosity of 4.4E34 erg/s. With the help of X-ray hardness ratios and optical and radio information different source classes can be distinguished. The survey detected 856 sources in an area of 1.24 square degrees. Sources within M 31 are 44 supernova remnants (SNR) and candidates, 18 super-soft sources (SSS), 16 X-ray binaries (XRBs) and candidates, as well as 37 globular cluster sources (GlC) and candidates, i.e. most likely low mass XRBs within the GlC. 567 hard sources may either be XRBs or Crab-like SNRs in M 31 or background AGN. 22 sources are new SNR candidates in M 31 based on X-ray selection criteria. Time variability information can be used to improve the source classification. Two GlC ...

2005-01-01

174

Energy Dispersive X-ray Analysis in the Electron Microscope  

CERN Document Server

Energy Dispersive X-ray Analysis in the Electron Microscope

2003-01-01

175

Inguino-scrotal hernia detection in the early phase of a bone scan  

International Nuclear Information System (INIS)

A large inguino-scrotal hernia was detected in the early phase of a radionuclide bone scan performed for evaluation of a femoral neck fracture not visualized on plain x-rays. The patient was administered 1 GBq of Scrotal scintigraphy using "9"9"mTc-MDP and a regional three-phase bone scan of the pelvis, hips and proximal femora was obtained on the gamma camera. Copyright (1999) Blackwell Science Pty Ltd

1999-11-01

176

Radioanalytical determination of chromium in welding fumes  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis and fast neutron activation analysis were used for the determination of chromium. The excitation source for X-ray fluorescence analysis was a ring-shaped "2"4"1Am source with an activity of 18.5x10"9 Bq. SYNPOR filters of 35 mm in diameter were used for the measurement. The 5.414 keV Cr peak was measured with a Si(Li) detector. The sensitivity was 0.05 mg for a period of measurement of 1000 s. A neutron generator with an emission of 10"9 s"-"1 was used as the source of fast neutrons. "5"2V and "5"3V, the products of nuclear reaction with Cr, were measured gamma spectrometrically with a Ge(Li) detector. The sensitivity for Cr is 0.015 mg, in the presence of Mn which causes interference the sensitivity is a mere 0.075 mg. The mentioned methods were used to determine total Cr and Cr(VI) in welding aerosols. It was found that the most toxic form, i.e., Cr(VI), is ...

1985-01-01

177

Radiation methods in research of ancient monuments  

Energy Technology Data Exchange (ETDEWEB)

A 'Laboratory of Quantitative Methods in Monument Research' is being built at the CTU Prague. Its primary orientation is the investigation of historic architecture, although other objects of art can also be investigated. In the first phase, two radiation methods are being established, but it is set up in such a way, that various other methods can readily be added in its future development. The radiation methods chosen for the initial development of the laboratory are: thermoluminescence dating and X-ray fluorescence analysis. The design of the automated TL-reader, built in our laboratories, is adjusted for the purpose of dating of historic brick architecture (which, of course, does not exclude applications for ceramics and other materials). The investigation of renaissance architecture in southern Bohemia and Moravia is under preparation as the first large campaign of this kind in the Czech Republic. Radionuclide ...

2000-11-15

178

Radiation methods in research of ancient monuments  

International Nuclear Information System (INIS)

A 'Laboratory of Quantitative Methods in Monument Research' is being built at the CTU Prague. Its primary orientation is the investigation of historic architecture, although other objects of art can also be investigated. In the first phase, two radiation methods are being established, but it is set up in such a way, that various other methods can readily be added in its future development. The radiation methods chosen for the initial development of the laboratory are: thermoluminescence dating and X-ray fluorescence analysis. The design of the automated TL-reader, built in our laboratories, is adjusted for the purpose of dating of historic brick architecture (which, of course, does not exclude applications for ceramics and other materials). The investigation of renaissance architecture in southern Bohemia and Moravia is under preparation as the first large campaign of this kind in the Czech Republic. Radionuclide X-ray ...

2000-11-15

179

Measuring head for radionuclide X-ray fluorescence analyzer  

International Nuclear Information System (INIS)

The design of a gaging head for a portable radionuclide X-ray fluorescence analyzer is described. The gaging head is designed as a construction unit system which enables the application of lateral reflexion geometry as well as of coaxial geometry. It is designed so that adjustment from one geometry to the other is labour and time saving. The selection of characteristic radiation is performed by a couple of Ross' differential filters. These filters are prepared by a novel technique developed by our laboratory. The filter exchange is effected by the longitudinal move of the couple of filters encapsulated in a holder. The shift of the filters is controlled by means of a triggering mechanism situated in the body of the gaging head handle. This design makes is possible to handle the gaging head during measurements with one hand. A simple interchange of the absorption filter for the transmissive filter allows the operator to avoid any unwanted shift ...

1976-05-21

180

Measurement of L X-ray fluorescence cross-sections for elements with 45 Z50 using synchrotron radiation at 8keV  

British Library Electronic Table of Contents (United Kingdom)

The L shell fluorescence cross-sections of the elements in range 45Z50 have been determined at 8keV using Synchrotron radiation. The individual L X-ray photons, Ll, La, LbI, LbII, LgI and LgII produced in the target were measured with high resolution Si(Li) detector. The experimental set-up provided a low background by using linearly polarized monoenergetic photon beam, improving the signal-to-noise ratio. The experimental cross-sections obtained in this work were compared with available experimental data from Scofield [1,2] Krause [3,4] and Scofield and Puri et al. [5,6]. These experimental values closely agree with the theoretical values calculated using Scofield and Krause data, except for the case of Lg, where values measured of this work are slighter higher.

2011-01-01

181

Six orders of magnitude dynamic range in capillary electrophoresis with ultrasensitive laser-induced fluorescence detection  

UK PubMed Central (United Kingdom)

An ultrasensitive laser-induced fluorescence detector was used with capillary electrophoresis for the study of 5-carboxy-tetramethylrhodamine. The raw signal from the detector provided roughly...Full Text Available

2009-12-15

182

Rate of allosteric change in hemoglobin measured by modulated excitation using fluorescence detection.  

UK PubMed Central (United Kingdom)

We have measured the forward and reverse rates of the allosteric transition of hemoglobin A with three CO molecules bound by using modulated excitation coupled with fluorescence quenching of the DPG...Full Text Available

1989-10-01

183

Improved DNA Sequencing Accuracy and Detection of Heterozygous Alleles Using Manganese Citrate and Different Fluorescent Dye Terminators  

UK PubMed Central (United Kingdom)

The use of dideoxynucleotide triphosphates labeled with different fluorescent dyes (dye terminators) is the most versatile method for automated DNA sequencing. However, variation in peak heights reduces...Full Text Available

1999-06-01

184

Early Detection of Bronchial Lesions Using Lung Imaging Fluorescence Endoscope  

UK PubMed Central (United Kingdom)

The performance of the Lung Imaging Fluorescence Endoscope (LIFE) system was compared with conventional bronchoscopy in 158 patients: 68 patients with invasive cancer, 42 patients with abnormal sputum...Full Text Available

1999-01-01

185

Radionuclide X-ray fluorescence analysis with environmental application  

International Nuclear Information System (INIS)

The purpose of this work is to present a comprehensive, instructive analysis of the basis of radionuclide XRFA, to describe methods of sample preparation for environmental analysis and to make the reader more familiar with the procedures, methods and instrumentation of radionuclide XRFA used in this field. This book discusses the use of radionuclide XRFA for solving analytical problems of the environment and information is presented concerning the current state of research and use of radionuclide XRFA in this significant area. The present volume will serve as a basic source of data and also as a laboratory handbook. refs.; figs.; tabs.

1990-01-01

186

Multielement XRF-analysis of blood from patients with dilated cardiomyopathy  

International Nuclear Information System (INIS)

Radionuclide x-ray fluorescence analysis was used for the determination of Fe, Zn, Br and Rb levels in whole blood from dilated cardiomyopathy patients and from a control group. The XRF-system consisted of a radionuclide source "1"0"9Cd, a semiconductor Si/Li detector connected to a multichannel analyzer. Fe content in blood of patients was significantly lower than that of the control. Zn content showed no deviation from normal range. Values for Br and Rb in patients highly exceed the range reported for them. (author) 4 tabs.; 9 refs.

1991-03-01

187

Elemental concentration analysis in some plant samples by EDXRF at Trabzon  

International Nuclear Information System (INIS)

The elemental analysis of some plant samples have been carried out in Trabzon region (Turkey) using energy-dispersive X-ray fluorescence (EDXRF) spectrometry. We have analyzed plant samples for nine stations using 1.85 GBq 55Fe radioactive sources. We have found that potassium and calcium within 0.3-1.4% and 0.3-2.8% were present in concentration in plants for every station, respectively. The concentration of Cl and Ti generally changed according to the plant species and the sampling station.

2006-12-01

188

Application of radionuclide X-ray fluorescence analysis in determining lanthanum content in tungsten and in iron by internal standard technique  

Energy Technology Data Exchange (ETDEWEB)

The use of the method is described on powder samples before and after sintering with a La content of up to 1%. For excitation of the K series of La a /sup 241/Am source with an activity of 1.11 GBq was used. The obtained results showed that the method is sufficiently accurate (error 7%) at a short period of measurement (100 s). It gives satisfactory results even in the comparison of the experimental relative count rate and the theoretically calculated value despite the fact that the analytical signal comes from the sample surface.

1983-05-01

189

Application of radionuclide X-ray fluorescence analysis in determining lanthanum content in tungsten and in iron by internal standard technique  

International Nuclear Information System (INIS)

The use of the method is described on powder samples before and after sintering with an La content of up to 1%. For excitation of the K series of La a _2_4_1Am source with an activity of 1.11 GBq was used. The obtained results showed that the method is sufficiently accurate (error 7%) at a short period of measurement (100 s). It gives satisfactory results even in the comparison of the experimental relative count rate and the theoretically calculated value despite the fact that the analytical signal comes from the sample surface. (Ha).

1983-01-01

190

6. Sample preparation for determining pollutants in components of the environment  

International Nuclear Information System (INIS)

Examples are given of reference materials for radionuclide X-ray fluorescence analysis (RXFA) of the environment processed by the National Bureau of Standards and the IAEA. Methods are described used for preparing standard materials for RXFA. For determining air pollutants the sample is prepared by dry or wet mineralization. Water samples have to be preserved prior to analysis. Insoluble components are separated by filtration or centrifugation. Biological materials must be dehydrated and homogenized. Samples of soil, sludges, sediments and solid wastes will sometimes have to be converted into a solution in some cases a leachate will have to be obtained. (ES).

1983-12-01

191

Magnified x-ray phase imaging using asymmetric Bragg reflection: Experiment and theory  

International Nuclear Information System (INIS)

X-ray imaging using asymmetric Bragg reflection in the hard x-ray regime opens the way to improve the spatial resolution limit below 1 #mu#m by magnifying the image before detection, simultaneously providing a strong phase contrast. A theoretical formalism of the imaging process is established. Based on this algorithm, numerical simulations are performed and demonstrate that both Fresnel propagation and Bragg diffraction contribute to contrast formation. The achievable resolution of this technique is investigated theoretically; the results obtained can be used to improve future experimental setups. Furthermore, the minimum detectable phase gradient is estimated, for comparison with other phase sensitive imaging techniques. Results from biological objects demonstrate that the technique is viable for imaging both in two and three dimensions. Refraction contrast images are extracted from experimental ...

2006-08-01

192

X-ray micro-spectroscopy: a tool for micro-scale radionuclide speciation in heterogeneous nuclear waste repository materials  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: Large-scale problems such as nuclear waste disposal are increasingly recognized to be interconnected to small scale-mechanisms. Thus, synchrotron-based high-resolution analytical X-ray probes become important tools for exploring the micro-scale chemical reactivity of heterogeneous barrier materials used in nuclear waste repositories. In this study the layout of the micro-XAS beamline at the Swiss Light Source (SLS) will be presented. The beamline is optimized towards micro beam experiments ({approx}1 x 1 {mu}m{sup 2}) in the hard-X-ray regime (4 - {approx}22 keV) and allows to combine micro X-ray fluorescence (micro-XRF), micro X-ray absorption spectroscopy (micro- XAS), and micro X-ray diffraction (micro-XRD) investigations with radioactive samples. Furthermore, the potential of micro-XRF/XAS/XRD for acquiring spatially ...

2005-07-01

193

Advantages of magnification in digital phase-contrast mammography using a practical X-ray tube  

Energy Technology Data Exchange (ETDEWEB)

Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point source results in a phase contrast too narrow for detection with CR. In addition to phase ...

2008-12-15

194

Information detective quantum efficiency of X-ray film-intensifier foil systems  

Energy Technology Data Exchange (ETDEWEB)

The capability of screen-film combinations of detection and representation of information is described by the detective quantum efficiency (DQE). The DQE may be calculated from the sensitivity, the gradient of the characteristic curve, the modulation transfer function and the Wiener spectrum. These parameters have been determined for fourteen screen-film combinations and the DQE's have been calculated. It is shown that the low frequency region the DQE does not depend on spatial frequency. This constant level of DQE is mostly dependent on the absorbance of the screens. Consequences from this fact, as well for the manufacturer as for the user of the screens, are discussed.

1988-04-01

195

Information detective quantum efficiency of X-ray film-intensifier foil systems  

International Nuclear Information System (INIS)

The capability of screen-film combinations of detection and representation of information is described by the detective quantum efficiency (DQE). The DQE may be calculated from the sensitivity, the gradient of the characteristic curve, the modulation transfer function and the Wiener spectrum. These parameters have been determined for fourteen screen-film combinations and the DQE's have been calculated. It is shown that the low frequency region the DQE does not depend on spatial frequency. This constant level of DQE is mostly dependent on the absorbance of the screens. Consequences from this fact, as well for the manufacturer as for the user of the screens, are discussed. (orig.).

196
197

Measurement of relative L X-ray intensity ratio following radioactive decay and photoionization  

Energy Technology Data Exchange (ETDEWEB)

The measurements of the L X-ray intensity ratio I(L{alpha})/I(L{beta}), I(L{alpha})/I(L{gamma}), I(L{alpha})/I(L{iota}), I(L{beta})/I(L{gamma}) and I(L{iota})/I(L{gamma}) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a filtered radioisotope {sup 241}Am was used, and by the radioactive decay of {sup 160}Tb, {sup 160}Er, {sup 173}Lu, {sup 182}Re, {sup 201}Tl, {sup 203}Pb and {sup 207}Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L{alpha}/L{beta}), I(L{alpha}/L{gamma}), I(L{alpha}/L{iota}), I(L{beta}/L{gamma}) and I(L{iota}/L{gamma}) intensity ratios were calculated using theoretically tabulated values of subshell photoionization cross-section, fluorescence yield, fractional ...

2008-05-22

198

Analysis of TL glow curves in differently doped LiF:Mg,Ti  

International Nuclear Information System (INIS)

A computerised curve-fitting method was developed to calculate the trapping parameters in LiF TLD-100 and LiF:Mg, Ti. After irradiation in a "6"0Co field and with X rays emitted at different voltages the TL process is best described by first-order kinetics. A dependence of the trapping parameters on both the concentration of Mg and Ti and photon energy was detected. (author).

199

Element distribution in the brain sections of rats measured by synchrotron radiation X-ray fluorescence  

International Nuclear Information System (INIS)

The concentration of trace elements in brain sections was measured by synchrotron radiation X-ray fluorescence. The relative concentration was calculated by means of the normalization of Compton scattering intensity approximately 22 keV, after the normalization for collecting time of X-ray spectrum and the counting of the ion chamber, and subtracting the contribution of the polycarbonate film for supporting sample. Furthermore, the statistical evaluation of the element distribution in various regions of the brain sections of the 20-day-old rats was tested. For investigating the distribution of elements in the brain of iodine deficient rats, Wistar rats were fed with iodine deficient diet and deionized water (ID group). The rats were fed the same iodine deficient diet, but drank KIO_3 solution as control (CT group). The results showed that the contents of calcium (Ca) in thalamus (TH) and copper (Cu) and iron (Fe) in ...

2004-02-27

200

Use of primary electron counting for detection of ultrasoft x-rays with a low-pressure multistep gaseous detector  

International Nuclear Information System (INIS)

The use of primary electron counting techniques as an alternative to the more usual parallel plate avalanche chamber that has been employed in soft x-ray scattering experiments is being investigated at the National Synchrotron Light Source. The theoretical aspects of primary electron counting and motivation behind building a primary electron counting detector are described, as well as characteristics and future improvements of the device constructed at the NSLS. The detector consists of a low electric field drift region and a low pressure multistep avalanche region which can be operated with two or three stages of electron multiplication. The device has worked well in extensive tests as a simple parallel plate avalanche chamber, providing energy resolutions of 58% and 43% at 277 and 500 eV, respectively. Operated as a primary electron counter, preliminary results show an energy resolution of 38% at 500 eV.

201

A study of reconstruction algorithms and filters for an industrial X-ray tomography system  

Energy Technology Data Exchange (ETDEWEB)

Computed tomography (CT) has been incorporated in an industrial Diode-Array Digital Radiography (DADR) system. An input data size of 512 pixel points x 400 projections yielded a 400x400 output image matrix. Reconstruction algorithms used are the filtered backprojection (FBP) and the direct Fourier reconstruction (DFR). Various filters were used in the FBP reconstruction process and their effects on image quality were evaluated. A spatial resolution of 100 {mu}m was measured with a block of plates and a minimum detectable feature size in the range of 10-100 {mu}m was measured using thin wires. Industrial specimens imaged have included ceramic samples, ball bearings and integrated circuits. A number of engineering problems have been solved, such as adjustment of the X-ray source, centering of the rotator spindle in the view field and beam-hardening corrections. (orig.).

1990-12-20

202

Synchrotron Self-Compton Analysis of TeV X-ray Selected BL Lacertae Objects  

CERN Document Server

We introduce a methodology for analysis of multiwavelength data from X-ray selected BL Lac (XBL) objects detected in the TeV regime. By assuming that the radio--through--X-ray flux from XBLs is nonthermal synchrotron radiation emitted by isotropically-distributed electrons in the randomly oriented magnetic field of a relativistic blazar jet, we obtain the electron spectrum. This spectrum is then used to deduce the synchrotron self-Compton (SSC) spectrum as a function of the Doppler factor, magnetic field, and variability timescale. The variability timescale is used to infer the comoving blob radius from light travel-time arguments, leaving only two parameters. With this approach, we accurately simulate the synchrotron and SSC spectrum of flaring XBLs in the Thomson through Klein-Nishina regimes. Photoabsorption by interactions with internal jet radiation and the intergalactic background light (IBL) is included. Doppler ...

2008-01-01

203

Suzaku and Optical Spectroscopic Observations of SS 433 in the 2006 April Multiwavelength Campaign  

CERN Document Server

We report results of the 2006 April multi-wavelengths campaign of SS 433, focusing on X-ray data observed with Suzaku at two orbital phases (in- and out-of- eclipse) and simultaneous optical spectroscopic observations. By analyzing the Fe25 K_alpha lines originating from the jets, we detect rapid variability of the Doppler shifts, dz/dt ~ 0.019/0.33 day^-1, which is larger than those expected from the precession and/or nodding motion. This phenomenon probably corresponding to "jitter" motions observed for the first time in X-rays, for which significant variability both in the jet angle and intrinsic speed is required. From the time lag of optical Doppler curves from those of X-rays, we estimate the distance of the optical jets from the base to be ~(3-4) \\times 10^14 cm. Based on the radiatively cooling jet model, we determine the innermost temperature of the jets to be T_0 = 13 +/- 2 keV and 16 +/- 3 ...

2010-01-01

204

Scintiscanning with aerosols of "9"9Tc"m DTPA in the diagnostic strategy for pneumocystosis in aids patients  

International Nuclear Information System (INIS)

Pulmonary clearance of an aerosol of "9"9Tc"m DTPA was measured in 21 non-smoking AIDS and pneumocystosis patients. The results were compared with those of pulmonary scintiscanning with gallium. All the patients exhibited increased clearance, evidence of a considerable alteration in alveolar permeability. This increase was also observed in patients with normal chest X-rays and normal blood gases. The average clearance in these patients was 6 #+-# 2% min"-"1 as compared with a normal 1.1 #+-# 0.3% min"-"1. Conversely, only four out of eight patients with normal chest X-rays had abnormal gallium scans. Clearance returned to normal after recovery. Measurement of DTPA clearance appears to be a very sensitive indicator for the detection and follow-up of pneumocystosis. However, it is not very specific since it can be increased by tobacco poisoning, drug abuse and the presence of lymphocytic alveolitis. An examination with normal ...

1988-08-15

205

Extreme Ultraviolet Emission from Abell 4059  

CERN Document Server

We present the results of a search for Extreme Ultraviolet emission in A4059, a cluster with an X-ray emitting cluster gas. Our analysis of Extreme Ultraviolet Explorer (EUVE) Deep Survey observations of this cluster shows that it is associated with diffuse EUV emission. Outside the central 2 arcmin radius the entire EUV emission detected is explained by the low energy tail of the X-ray emitting gas. Within the central 2 arcmin region of the cluster we find a deficit of EUV emission compared to that expected from the X-ray gas. This flux deficit is discussed in the context of the cluster's cooling flow. The results derived for A4059 are compared to EUVE results obtained for other clusters such as Coma, Virgo, A1795, and A2199. As part of the study we have carried out a detailed investigation of the stability of the EUVE Deep Survey detector background. Based on long integrations of blank sky over 27 ...

2000-01-01

210

Sampling and analytical methodologies for energy dispersive X-ray fluorescence analysis of airborne particulate matter  

International Nuclear Information System (INIS)

The present document represents an attempt to summarize the most important features of the different forms of ED-XFR as applied to the analysis of airborne particulate matter. It is intended to serve as a set of guidelines for use by participants in the IAEA's own programmes, and other scientists, who are not yet fully experienced in the application of ED-XRF to airborne particulate samples, and who wish either to make a start on using this technique or to improve their existing procedures. The methodologies for sampling described in this document are of rather general applicability. Emphasis is also placed on the sources of errors affecting the sampling of airborne particulate matter. The analytical part of the document describes the different forms of ED-XRF and their potential applications. Spectrum evaluation, a key step in X-ray spectrometry, is covered in depth, including discussion on several calibration and peak fitting techniques and computer programs ...

1986-06-25

211

Removal of Cr(III) from aqueous solutions using zeolite NaY prepared from rice husk ash  

International Nuclear Information System (INIS)

The efficiency of the synthesized zeolite NaY from rice husk ash (RHA) in the removal of Cr(III) from aqueous solution was studied. Zeolite NaY was synthesized from RHA via seeding technique and the identification of its structure was done by X-ray Diffraction (XRD) technique and the elemental analysis was carried out by X-ray Fluorescence (XRF). The physicochemical properties which were related to the use of the zeolite NaY as a sorbent was also investigated. The synthesized zeolite NaY has higher cation exchange capacity (CEC) than the commercial zeolite NaY due to the higher amount of sodium content in the synthesized as well as the lower ratio of silica to alumina. The synthesized zeolite NaY together with the commercial one as comparison was used in the sorption of the Cr(III) in aqueous solution by batch sorption experiments. The kinetic study showed that the Cr(III) uptake by both zeolites were based on the pseudo ...

2007-01-01

212

Noninvasive analysis of skin iron and zinc levels in beta-thalassemia major and intermedia  

Energy Technology Data Exchange (ETDEWEB)

Diagnostic x-ray spectrometry, a method based on x-ray fluorescence analysis, was used for noninvasive determination of iron and zinc in two distinct skin areas, representing predominantly dermal and epidermal tissues, in 56 patients with beta-thalassemia major and intermedia. The mean iron levels in the skin of patients with beta-thalassemia major and intermedia were elevated by greater than 200% and greater than 50%, respectively, compared with control values. The zinc levels of both skin areas examined were within the normal range. The data indicate that the rate and number of blood transfusions, which correlated well with serum ferritin levels (r . 0.8), are not the only factors that determine the amount of iron deposition in the skin (r less than 0.6). Other sources of iron intake contribute to the total iron load in the tissues, particularly in patients who are not given multiple transfusions. The noninvasive ...

1985-01-01

213

Development of sialon using Yttria and alumina as additive  

International Nuclear Information System (INIS)

Full text: The production of #beta#-sialon from kaolinite and carbon has been studied using Hulu Langat Kaolin and activated carbon as raw materials. The sintered temperature is shown to play a prominent role in the process of sialon conversion. Apart from temperature, nitrogen flow rate is also affect the production of #beta#--sialon. This study was carried out on the effect of additive, Y_2O_3 and Al_2O_3 at different temperature that will be mixed and sintered. The additives are expected to affect the formation of #beta#--sialon and Y-sialon upon the synthesis. The mineral and phase development was analysed using X-Ray Diffraction technique (Rigaku Geigerflex) while its chemical compositions through X-Ray Fluorescent Spectrophotometer (Shimadzu XRF 1700) and the particle size distribution analysis through Particle Size Analyser (Horiba, CAPA 700). The observed changes in the microstructure were analysed using the Hitachi ...

2005-08-16

214

Cd speciation in biomass fly ash particles after size separation by centrifugal SPLITT  

Energy Technology Data Exchange (ETDEWEB)

The finest particle size fractions ({le} 25 {mu}m) in four fly ash samples from fluidised bed combustion of three biomass based fuels and a municipal solid waste fuel were size separated using a centrifugal SPLITT fractionation cell. The ashes were separated into different size fractions and the cadmium concentration, partition and speciation in each separated fraction were then investigated in relation to their possible leaching. The fractionation was evaluated by environmental scanning electron microscopy, which also provided indications of the associations between Cd and other main elements on the particles through the use of X-ray fluorescence mapping. The total concentration of Cd in each fraction was determined by AAS analysis which showed different dependence on the ash particle size in the case of biomass or waste fuels. In addition, the speciation of Cd in each fraction, investigated by sequential chemical extractions and ...

2002-08-01

215

The X-ray Ordinance  

International Nuclear Information System (INIS)

The sections and provisions of the X-ray Ordinance of January 8, 1987 are discussed which are of relevance to dental radiology. (DG).

216

Scintigraphic detection of a radiologically equivocal fracture  

Energy Technology Data Exchange (ETDEWEB)

This case report makes evident that in a 75 years old patient with a (cured) femoral neck fracture 15 years ago a refracture at the same site following a new trauma could not be detected by conventional X-ray. The follow-up of a radionuclide bone study, however, enabled the dignosis of a refracture. From these findings, it is further evident that the decreased bone metabolism in older patients has to be considered. Thus, although the initial bone scan following the trauma is negative, a follow-up scan should be performed within a 4 day-period.

1988-04-01

217

Scintigraphic detection of a radiologically equivocal fracture  

International Nuclear Information System (INIS)

This case report makes evident that in a 75 years old patient with a (cured) femoral neck fracture 15 years ago a refracture at the same site following a new trauma could not be detected by conventional X-ray. The follow-up of a radionuclide bone study, however, enabled the dignosis of a refracture. From these findings, it is further evident that the decreased bone metabolism in older patients has to be considered. Thus, although the initial bone scan following the trauma is negative, a follow-up scan should be performed within a 4 day-period. (orig.).

218

Lung cancer screening program using annual chest radiographs with computed radiography (FCR)  

Energy Technology Data Exchange (ETDEWEB)

In the Wajima lung cancer screening program conducted under the auspices of Kanazawa University Hospital, Fuji Computed Radiography (FCR) was utilized in a new chest radiography trial. The results of the screening program are that the necessity of repeat examinations due to poor image quality are less common and the method enables detection of small pulmonary nodular shadows which are possibly candidates for surgery. Oblique chest X-ray with FCR is remarkably effective for the detection and the identification of small lesions. However, the disadvantage of slow processing and high cost must be fully satisfied if FCR is to become a new imaging modality for mass screening.

1987-08-01

219

Lung cancer screening program using annual chest radiographs with computed radiography (FCR)  

International Nuclear Information System (INIS)

In the Wajima lung cancer screening program conducted under the auspices of Kanazawa University Hospital, Fuji Computed Radiography (FCR) was utilized in a new chest radiography trial. The results of the screening program are that the necessity of repeat examinations due to poor image quality are less common and the method enables detection of small pulmonary nodular shadows which are possibly candidates for surgery. Oblique chest X-ray with FCR is remarkably effective for the detection and the identification of small lesions. However, the disadvantage of slow processing and high cost must be fully satisfied if FCR is to become a new imaging modality for mass screening. (author).

1987-01-01

220

PROBING THE ORIGINS OF THE C IV AND Fe K? BALDWIN EFFECTS  

International Nuclear Information System (INIS)

We use UV/optical and X-ray observations of 272 radio-quiet Type 1 active galactic nuclei and quasars to investigate the C IV Baldwin Effect (BEff). The UV/optical spectra are drawn from the Hubble Space Telescope, International Ultraviolet Explorer and Sloan Digital Sky Survey archives. The X-ray spectra are from the Chandra and XMM-Newton archives. We apply correlation and partial-correlation analyses to the equivalent widths (EWs), continuum monochromatic luminosities, and ?ox, which characterizes the relative X-ray to UV brightness. The EW of the C IV ?1549 emission line is correlated with both ?ox and luminosity. We find that by regressing l?(2500 A) with EW(C IV) and ?ox, we can obtain tighter correlations than by regressing l?(2500 A) with only EW(C IV). Both correlation and regression analyses imply that l?(2500 A) is not the only factor controlling the changes of EW(C IV); ?ox (or, equivalently, the soft ...

2009-09-01

221

Occurrence of mutations in the epidermal growth factor receptor gene in X-ray-induced rat lung tumors  

International Nuclear Information System (INIS)

Epidermal growth factor receptor (EGFR) gene alterations have been found in human lung cancers. However, there is no information on the factors inducing EGFR mutations. In rodents, K-ras mutations are frequently found in many lung carcinogenesis models, but hitherto, Egfr mutations have not been reported. Their presence was therefore investigated in representative lung carcinogenesis models with 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), N-nitrosobis(2-hydroxypropyl)amine (BHP), 2-amino-3,8-dimethylimidazo[4,5-f]quinoxaline (MelQx) and ethyl carbamate (urethane), as well as X-ray irradiation. With the chemical carcinogenesis models, no mutations were detected in Egfr, which is in clear contrast to the high rates observed in either codon 12 or 61 of K-ras (21/23 of the lung tumors induced with NNK, 4/5 with MelQx, 1/4 with urethane and 7/18 with BHP). However, in the X-ray-induced lung tumors, Egfr mutations with ...

2008-02-01

222

[Study of body composition by potassium-40 measurement in patients with breast and uterine cancer].  

Science.gov (United States)

Total potassium was assayed in 150 normal weight and obese females (cervical carcinoma-52, endometrial carcinoma-25 and breast cancer-73) by measurements of 40K spontaneous radiation in a low-background chamber. Control group included 30 healthy and 25 obese females. Computations of body cell and extracellular mass and fat were carried out on the basis of the said measurements. Extracellular fluid volume was measured in 38 patients by X-ray fluorescence method using sodium bromide. The results pointed to a body cell mass deficit matched by increased extracellular mass due to a higher fat level in patients with breast, endometrial and cervical carcinoma. The said correlation was particularly pronounced in obese patients. The beneficial effect of treatment was more often observed in patients with normal body weight. PMID:3739295

1986-01-01

223

Synthesis, crystal structure, spectroscopic properties, antibacterial activity and theoretical studies of a novel difunctional acylhydrazone  

British Library Electronic Table of Contents (United Kingdom)

A novel difunctional acylhydrazone has been synthesized by the reaction of 5-methylisoxazole-4-carboyl hydrazine with benzaldehyde and characterized by X-ray crystallography and spectroscopy. The obtained results demonstrate the crystal belongs to triclinic, space group Formula Not Shown . Moreover, the spectroscopic properties were evaluated through density functional theory (DFT) and time-dependent density functional theory (TD DFT) calculations. The results reveal that UV-Vis absorption peaks at 194, 217.5 and 290.5nm are mainly attributed to (p, p)p*, partly (p, p)p* and partly pp*, and predominantly pp*, respectively, with intraligand charge-transfer transition (ILCT) character. The fluorescence emission peak at 485.96nm should be assigned to ILCT. In addition, the results of antibact...

2011-01-01

224

Nuclear analytical techniques in Cuban sugar industry  

Energy Technology Data Exchange (ETDEWEB)

This paper is a review concerning the application of Nuclear Analytical Techniques in the Cuban sugar industry. The most complete elemental composition of final molasses (34 elements) and natural zeolites (38) this last one employed as an auxiliary agent in sugar technological processe4s has been performed by means of instrumental Neutron Activation Analysis (INAA) and X-Ray Fluorescence Analysis (XRFA). The trace elemental sugar cane soill-plant relationship and elemental composition of different types of Cuban sugar (raw, blanco-directo and refine) were also studied. As a result, valuable information referred to the possibilities of using these products in animal and human foodstuff so as in the other applications are given. (author). 34 refs., 6 figs., 1 tab.

1997-12-01

225

Microanalytical method development for Fe, Cu and Zn determination in colorectal cancer cells  

British Library Electronic Table of Contents (United Kingdom)

Microanalytical methods suitable for the determination of Fe, Cu in HT-29 (human colon adenocarcinoma) cells treated with different iron compounds (Fe(II) sulfate, Fe(III) chloride, Fe(III) citrate and Fe(III) transferrin) and cultured in medium supplemented or not with 10% (v/v) fetal calf serum (FCS) by total reflection X-ray fluorescence spectrometry (TXRF) and simultaneous graphite furnace atomic absorption spectrometry (GF-AAS) were developed. The developed TXRF method was also suitable for Zn determination in the samples. The main advantage of the proposed methods is the execution of all sample preparation steps following incubation and prior to the elemental analysis in the same Eppendorf tubes. Sample preparation was performed at microscale (115mL sample volume) with 65% nitric aci...

2011-01-01

226

Elemental analysis of savannah grass' burning ashes  

International Nuclear Information System (INIS)

In order to quantify the biomass burning emissions, the main atmospheric pollution source of tropical and subtropical regions, we carried out the analysis of ashes that are also formed during these fires. To this end, we developed analytical methods to characterize the composition of savannah grass burning ashes by using X-ray fluorescence for mineral elements and microanalysis for C, H, O and N. Samples used in this work have been collected during laboratory combustion experiments, with chemically well-defined natural savannah grasses from Ivory Coasts and South Africa. The reproducibility and efficiency of different developed procedures have been studies. The analytical relative precision is generally better than 5%. This development has allowed to establish, for the first time, the global mass balance of ashes resulting from savannah grass burning. (authors). 16 refs., 3 figs., 8 tabs.

227

Determining concentration distribution of admixture from count ratemeter response in continuous analyses  

International Nuclear Information System (INIS)

A comparison is made of the response of a count ratemeter and a pulse counter using the mathematical tool of the Z transform. Transform Z is used for the solution of the convolution integral interpreting the analog output of the count ratemeter used for recording characteristic radiation, excited in the moving beam. The comparison of count rates obtained by the count ratemeter during continuous analysis and the pulse counter during discontinuous measurement gave the transfer function of the count ratemeter in the actual range of count rate. Also discussed is the use of the transfer function for localizing concentration changes in the sample. The use of the described method is demonstrated on the determination of the tin content in tungsten using continuous radionuclide X-ray fluorescence analysis. (B.S.).

1983-01-01

228

Application of nuclear analytical methods in determining heavy metals in a welder's working environment  

International Nuclear Information System (INIS)

The problems are discussed of using radionuclide X-ray fluorescence analysis (the most frequently used source is "2"4"1Am) and neutron activation analysis for monitoring the chemical quality of the working environment of a welder. Elements determinable by these methods are listed and the advantages of the methods stated with regard to speed, simplicity and appropriate accuracy of measurement together with commercial availability of the instruments. Welding as a source of harmful substances is assessed by determination of the amount of chromium in aerosols generated by welding austenitic chromium-nickel steels. The described methods allow to obtain a complex image of the chemical nature of welding aerosols and to understand the mechanism of their impact on the human organism. (J.C.).

1986-01-01

229

5. Sampling  

International Nuclear Information System (INIS)

The sampling is described for radionuclide X-ray fluorescence analysis. Aerosols are captured with various filter materials whose properties are summed up in the table. Fine dispersed solid and liquid particles and gaseous admixtures may be captured by bubbling air through a suitable absorption solution. The concentration of small amounts of impurities from large volumes of air is done by adsorbing impurities on surfactants, e.g., activated charcoal, silica gel, etc. Aerosols may be captured using an electrostatic precipitator and aerosol fractions may be separated with a cascade impactor. Water sampling differs by the water source, i.e., ground water, surface water, rain or waste water. Soil samples are taken by probes. (ES).

1983-12-01

230

Depth-profiling of vertical sidewall nanolayers on structured wafers by grazing incidence X-ray flourescence  

Energy Technology Data Exchange (ETDEWEB)

The Physikalisch-Technische Bundesanstalt (PTB), Germany's national metrology institute, developed an alignment strategy to specify elemental depth profiling in vertical sidewall layers on structured wafers. For this purpose, PTB's irradiation chamber for 200 mm and 300 mm silicon wafers was used to combine total-reflection X-ray fluorescence (TXRF) and grazing incidence XRF (GIXRF) techniques by employing monochromatized undulator radiation of the BESSY II electron storage ring. 3-D test structures were fabricated to develop an optimal alignment strategy allowing for depth profiling in such nanolayers. The test structures consisted of silicon bars with widths/spacings either in the {mu}m or in the nm range. In order to be able to differentiate the sidewalls more easily from the remainder of the structures, they were provided with an additional silicon nitride layer. Four structure types of different bar width and density ...

2008-12-15

231

Depth-profiling of vertical sidewall nanolayers on structured wafers by grazing incidence X-ray flourescence  

International Nuclear Information System (INIS)

The Physikalisch-Technische Bundesanstalt (PTB), Germany's national metrology institute, developed an alignment strategy to specify elemental depth profiling in vertical sidewall layers on structured wafers. For this purpose, PTB's irradiation chamber for 200 mm and 300 mm silicon wafers was used to combine total-reflection X-ray fluorescence (TXRF) and grazing incidence XRF (GIXRF) techniques by employing monochromatized undulator radiation of the BESSY II electron storage ring. 3-D test structures were fabricated to develop an optimal alignment strategy allowing for depth profiling in such nanolayers. The test structures consisted of silicon bars with widths/spacings either in the ?m or in the nm range. In order to be able to differentiate the sidewalls more easily from the remainder of the structures, they were provided with an additional silicon nitride layer. Four structure types of different bar width and density parameters on two 200 mm ...

2008-12-01

232

Phase imaging using laser-produced X-ray sources  

International Nuclear Information System (INIS)

A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. The authors established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging

2000-08-01

233

Gene rearrangement and radiation carcinogenesis  

International Nuclear Information System (INIS)

The development of leukemia and thyroid cancer is characterized by activation of the abl oncogene and ret oncogene, respectively. In order to clarify the relationship between these gene aberrations and radiation, the pro-myelogenous leukemia-derived cell line HL60 and the thyroid cancer-derived cell line 8505C, were irradiated in vitro with 100Gy of X-rays. RNA was then extracted from 10"8 cells of the respective cell lines and examined by the reverse transcription PCR method for rearrangements of abl and ret genes. Five kinds of positive bands were observed in the HL-60 cells irradiated with 100Gy of X-ray. Similarly, six positive bands were also observed in the 8505C cells irradiated with 100Gy. In vitro X-irradiation activation of oncogenes found in radiation induced cancers imply that gene rearrangement by X-rays is involved in the development of malignant tumors. Furthermore, in an experiment to ...

1993-11-01

234

Detection of constitutive heterodimerization of the integrin Mac-1 subunits by fluorescence resonance energy transfer in living cells  

International Nuclear Information System (INIS)

Macrophage differentiation antigen associated with complement three receptor function (Mac-1) belongs to #beta#_2 subfamily of integrins that mediate important cell-cell and cell-extracellular matrix interactions. Biochemical studies have indicated that Mac-1 is a constitutive heterodimer in vitro. Here, we detected the heterodimerization of Mac-1 subunits in living cells by means of two fluorescence resonance energy transfer (FRET) techniques (fluorescence microscopy and fluorescence spectroscopy) and our results demonstrated that there is constitutive heterodimerization of the Mac-1 subunits and this constitutive heterodimerization of the Mac-1 subunits is cell-type independent. Through FRET imaging, we found that heterodimers of Mac-1 mainly localized in plasma membrane, perinuclear, and Golgi area in living cells. Furthermore, through analysis of the estimated physical distances between cyan ...

2006-08-04

235

Element selective X-ray magnetic circular and linear dichroisms in ferrimagnetic yttrium iron garnet films  

Energy Technology Data Exchange (ETDEWEB)

X-ray magnetic circular dichroism (XMCD) was used to probe the existence of induced magnetic moments in yttrium iron garnet (YIG) films in which yttrium is partly substituted with lanthanum, lutetium or bismuth. Spin polarization of the 4d states of yttrium and of the 5d states of lanthanum or lutetium was clearly demonstrated. Angular momentum resolved d-DOS of yttrium and lanthanun was shown to be split by the crystal field, the two resolved substructures having opposite magnetic polarization. The existence of a weak orbital moment involving the 6p states of bismuth was definitely established with the detection of a small XMCD signal at the Bi M{sub 1}-edge. Difference spectra also enhanced the visibility of subtle changes in the Fe K-edge XMCD spectra of YIG and {l_brace}Y, Bi{r_brace}IG films. Weak natural X-ray linear dichroism signatures were systematically observed with all iron garnet films and with a bulk YIG ...

2009-12-15

236

The amount of bone mineral and Schmorl's nodes in lumbar vertebrae.  

Science.gov (United States)

The bone mineral areal content and the ultimate compressive strength were determined in 109 lumbar vertebrae from 36 subjects. The bone mineral areal content was related to the number, shape, and localization of the Schmorl's nodes detected in the x-rayed and sectioned vertebral bodies. One type of node, irregular in shape and localization, occurred only in the vertebrae with low bone mineral areal content values and thus in vertebrae with relatively low compressive strength. A second type of Schmorl's nodes, regular in shape and localization, did not reflect any general weakness of the vertebral bodies. PMID:6623194

1983-04-01

237

Study of titanium-niobium alloys manufactured by magnesium thermic reduction of chlorides  

International Nuclear Information System (INIS)

Chemical and phase homogeneity of titanium-niobium sponge, produced by a combined magnesium-thermic reduction of niobium pentachloride and titanium tetrachloride mixtures, is investigated. It is ascertained that a sponge consists of spherical shape particles and has a large number of pores. Particle sizes are reduced with niobium being substituted for titanium from 50-500 #mu#m for titanium sponge to 1-40 #mu#m for niobium one, which testifies to the bormation in a titanium-niobium sponge of an alloy and not a mechanical mixture. A number of solid solutions is detected by X-ray phase analysis. Lattice parameters are determined.

238

Ion beam analysis of high temperature superconducting samples  

Energy Technology Data Exchange (ETDEWEB)

Characterization of high temperature superconducting film and bulk samples has been carried out using 2 MeV [alpha]-particle Rutherford backscattering, 2.4 MeV proton elastic scattering, 2.4 MeV proton-induced x-ray emission, 9 MeV proton induced [gamma]-ray emission and 100 MeV iodine elastic recoil detection analysis techniques. The objective was to compare different ion beam based techniques for: (i) compositional analysis; and (ii) consistency of the results obtained for samples prepared using similar preparation methodology. (author).

1994-02-01

239

Improved beam confinement in the modified betatron with strong focusing  

International Nuclear Information System (INIS)

The lifetime of the circulating electron beam in the Naval Research Laboratory modified betatron has been increased by more than 2 orders of magnitude with the addition of strong focusing windings to the device. The injected beam consistently spirals from the injector to the minor axis and is trapped. The #approx#0.5-kA trapped electron ring has been accelerated above 10 MeV from the injection energy of 0.5 to 0.6 MeV. The beam acceleration has been confirmed not only by the x-ray attenuation technique but also with the detection of photoneutrons.

240

Evolution of the white dwarf mass and spin in cataclysmic variables  

International Nuclear Information System (INIS)

We consider the spin-up of the white dwarf in non-magnetic cataclysmic variables (CVs) during secular evolution. If this is unresisted, CVs are quenched as boundary-layer emitters once the binary period has decreased by #approx# 1 hr. Angular momentum loss in nova explosions may, however, prevent the star reaching breakup. If the explosions remove (1 + #epsilon#) x the mass accreted between outbursts, values 0.5 < #approx# #epsilon# < #approx# 1 allow CVs to be modest boundary-layer emitters for most of their lifetimes. Spectral effects will limit their detection as soft X-ray sources. (author).

241

Coherent Synchrotron Radiation as a Diagnostic Tool for the LCLS Longitudinal Feedback System  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL). To ensure the vitality of FEL lasing, a longitudinal feedback system is required together with other diagnostics. In this paper, we study the possibility of using Coherent Synchrotron Radiation (CSR) from the chicane as a diagnostic tool for bunch length feedback. Studies show that CSR is a good candidate, even for a non-Gaussian, double-horn longitudinal charge distribution as in the LCLS. We further check the possibility for detecting possible microbunching.

2005-06-15

242

''SEPIO NUANCE DT'' digital mammography system  

International Nuclear Information System (INIS)

In the past, the need for high quality images, i.e., very sharp and clear images, in mammography have prevented mammography equipment from being digitalized; however, recent advances in detection technology such as development of a high resolution digital X-ray detector have produced improvements in digital mammography. Digital mammography is expected to replace conventional film-screen mammography. We have developed a digital mammography system, named ''SEPIO NUANCE DT'', which is equipped with a direct conversion flat panel detector. The present paper describes the high basic performance and user-friendly functions of the system. (author)

2007-03-01

243

Position sensitive detection of individual nuclear particle scintillations using image intensifier tubes  

International Nuclear Information System (INIS)

An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).

1996-01-01

244

Graphene-Pt nanocomposite for nonenzymatic detection of hydrogen peroxide with enhanced sensitivity  

British Library Electronic Table of Contents (United Kingdom)

A sensitive hydrogen peroxide (H2O2) sensor was fabricated based on graphene-Pt (GN-Pt) nanocomposite. The GN-Pt was synthesized by photochemical reduction of K2PtCl4 on GNs, and characterized by atomic force microscope (AFM), transmission electron microscope (TEM), and energy-dispersive X-ray spectroscopy (EDS). Electrochemical investigations indicated that the GN-Pt exhibited a high peak current and low overpotential towards the reduction of H2O2. The GN-Pt modified glass carbon electrode displayed a wide linear range (2-710mM), low limit of detection (0.5mM) and good selectivity for detection of H2O2 with a much higher sensitivity than that of Pt nanoparticles or graphene modified electrode.

2011-01-01

245

X-ray magnetic circular dichroism measurements using an X-ray phase retarder on the BM25 A-SpLine beamline at the ESRF  

UK PubMed Central (United Kingdom)

Circularly polarized X-rays produced by a diamond X-ray phase retarder of thickness 0.5 mm in the Laue transmission configuration have been used for recording X-ray magnetic circular dichroism...Full Text Available

2010-05-01

246

Direct Comparison of the X-Ray Emission and Absorption of Cerium Oxide  

Energy Technology Data Exchange (ETDEWEB)

Bremstrahlung Isochromat Spectroscopy (BIS). The XES spectra were collected using a Specs electron gun for the excitation and the XES 350 grating monochromator and channel plate system from Scienta as the photon detection. Spectra were collected in 'normal mode,' where the electron gun kinetic energy (KE) and the energy position of the center of the channel plate were both fixed and the energy distribution in the photon (hv) spectrum was derived from the intensities distributed across the channel plate detector in the energy dispersal direction. The polycrystalline Ce sample was oxidized by exposure to air at ambient pressures. After introduction to the ultra-high vacuum system, the oxidized sample was bombarded with Ar, to clean the topmost surface region and stabilize the surface and near surface regions. Although CeO{sub 2} would be the thermodynamically preferred composition in an oxygen rich environment, the combination of a vacuum ...

2010-11-24

247

High-Sensitivity Analysis of Naturally Occurring Sugar Chains, Using a Novel Fluorescent Linker Molecule  

UK PubMed Central (United Kingdom)

To analyse the binding of sugar chains to proteins, viruses and cells, the surface plasmon resonance (SPR) technique is very convenient and effective because it is a real-time, non-destructive detection...Full Text Available

2009-07-01

248

Evaluation of Multiplexed Fluorescent Microsphere Immunoassay for Detection of Autoantibodies to Nuclear Antigens  

UK PubMed Central (United Kingdom)

Antibodies to extractable nuclear antigens (ENA) are found in a variety of collagen vascular diseases. Determining the individual specificities of these antibodies is extremely useful in establishing...Full Text Available

2004-11-01

249

X-ray stars in globular clusters  

Science.gov (United States)

The properties and kinetics of x-ray stars in globular clusters are described. Locations, configurations, star evolution, massive close binary systems, various mechanisms, and the x-ray burster properties are included. (JFP)

1977-10-01

250

X-ray dose enhancement effects  

International Nuclear Information System (INIS)

A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.

251

Position-sensitive proportional counter for space-based X-ray imaging studies  

International Nuclear Information System (INIS)

ASTROSAT, India's first dedicated astronomy satellite is slated for launch in 2007. The primary science objective of ASTROSAT is to explore the Universe using broad-band instruments covering optical, UV, soft X-ray and hard X-ray studies

2005-03-01

252

Beam-induced damage on diffractive hard X-ray optics  

UK PubMed Central (United Kingdom)

The issue of beam-induced damage on diffractive hard X-ray optics is addressed. For this purpose a systematic study on the radiation damage induced by a high-power X-ray beam is carried out in both...Full Text Available

2010-11-01

253

Photoacoustic response to X-ray absorption in copper and brass  

Energy Technology Data Exchange (ETDEWEB)

The X-ray photoacoustic spectra of copper and brass (64.7 wt.% Cu and 35.3 wt.% Zn) have been measured at XANES (X-ray absorption near-edge structure) regions using synchrotron radiation. These spectra were compared with optical density of X-ray spectra. It is shown that the information derived from XANES is also included in the X-ray photoacoustic spectrum which reflects the heat production processes in copper and brass. However, the results showed that the increases and changes of the photoacoustic signal were different from those of the X-ray absorption coefficient at XANES regions. (author).

1990-09-01

254

Generation of microwaves and hard X-rays in a flash X-ray tube  

Energy Technology Data Exchange (ETDEWEB)

High interelectrode voltage peaks have been observed simultaneously with the emission of hard X-ray bursts from a flash X-ray tube. The magnitude of the voltage peaks may exceed twice the initial charging voltage. It has also been observed that the discharge emits bursts of X-and P-band microwaves radiation which are coincident with the emission of the hard X-ray bursts. The results indicate that the microwaves and X-rays have a common origin in discharge plasma movements and an acceleration model for electrons in the plasma is presented as one possible explanation of the observed phenomena.

1982-01-01

255

Micro area analysis and measurement of electronic device material (challenge to utmost limits). Characterization of interface elect`ron structure by photon-and electron-spectroscopies; Denshi debaisu yo zairyo no bisho ryoiki bunseki-keisoku (kyokugen eno chosen). Koshi-denshi bunkoho ni yoru kaimen denshi jotai hyoka  

Energy Technology Data Exchange (ETDEWEB)

A method for detecting electrons emitted as secondary particles by photon incidence to a specimen, as well as a method of using the photons emitted by electron incidence as detecting particles are explained. Pd-Si(100)2{times}1 system is adopted for a case study of using photo-electron spectroscopy where synchrotron emitted light in soft X-ray region is used as the incident light. Pd atoms are deposited little by little on clean Si surface to investigate the electron structure of the surface, and the interface electron structure after bonded formation of Pd(thin film)-Si(substrate) is estimated. Radiation soft X-ray spectroscopy is employed to observe the real state of the bonded interface of Pd(thin film)-Si(substrate) prepared by depositing Pd film in a short period of time. In the case of radiation soft X-ray spectroscopy with electron beam excitation, bonded system of thin film ...

1995-07-20

256

Experimental and clinical studies on the usefulness and assessment of the angiographic images processed by a digital radiography system (FCR: Fuji Computed Tomography)  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film ...

1989-06-01

257

Experimental and clinical studies on the usefulness and assessment of the angiographic images processed by a digital radiography system (FCR: Fuji Computed Tomography)  

International Nuclear Information System (INIS)

The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film ...

1989-01-01

258

Variability and spectral modeling of the hard X-ray emission of GX 339-4 in a bright low/hard state  

CERN Document Server

We study the high-energy emission of the Galactic black hole candidate GX 339-4 using INTEGRAL/SPI and simultaneous RXTE/PCA data. By the end of January 2007, when it reached its peak luminosity in hard X-rays, the source was in a bright hard state. The SPI data from this period show a good signal to noise ratio, allowing a detailed study of the spectral energy distribution up to several hundred keV. As a main result, we report on the detection of a variable hard spectral feature (>150 keV) which represents a significant excess with respect to the cutoff power law shape of the spectrum. The SPI data suggest that the intensity of this feature is positively correlated with the 25 - 50 keV luminosity of the source and the associated variability time scale is shorter than 7 hours. The simultaneous PCA data, however, show no significant change in the spectral shape, indicating that the source is not undergoing a canonical state transition. We ...

2010-01-01

259

Time-Resolved Aerosol Collector for CCSEM/EDX Single Particle Analysis  

Energy Technology Data Exchange (ETDEWEB)

An automated Time Resolved Aerosol Collector (TRAC) has been developed for sequential sampling of field-collected aerosols for laboratory-based Computer Controlled Scanning Electron Microscopy/Energy Dispersed X-ray (CCSEM/EDX) single particle analysis. The collector is optimized for use of grid-supported 20 nm carbon films as deposition substrates. The carbon films have low enough X-ray background to permit EDX analysis down to 0.1-0.2 ?m particles, including detection of low-Z elements: C, N, & O. The TRAC provides unattended sampling onto a set of 151 individual grids, at sequential time intervals as short as 1 min. After collection, the samples are sealed and refrigerated pending analysis. The utility of the TRAC-CCSEM/EDX approach is exemplified using the aerosol samples collected during the Texas 2000 Air Quality Studies (Aug. 15 ? Sept. 15, 2000). We are able to quantitatively follow the time evolution in the ...

2003-01-02

260

The XMM-Newton wide-field survey in the COSMOS field. IV: X-ray spectral properties of Active Galactic Nuclei  

CERN Document Server

We present a detailed spectral analysis of point-like X-ray sources in the XMM-COSMOS field. Our sample of 135 sources only includes those that have more than 100 net counts in the 0.3-10 keV energy band and have been identified through optical spectroscopy. The majority of the sources are well described by a simple power-law model with either no absorption (76%) or a significant intrinsic, absorbing column (20%).As expected, the distribution of intrinsic absorbing column densities is markedly different between AGN with or without broad optical emission lines. We find within our sample four Type-2 QSOs candidates (L_X > 10^44 erg/s, N_H > 10^22 cm^-2), with a spectral energy distribution well reproduced by a composite Seyfert-2 spectrum, that demonstrates the strength of the wide field XMM/COSMOS survey to detect these rare and underrepresented sources.

2006-01-01

261

The End of Amnesia: A New Method for Measuring the Metallicity of Type Ia Supernova Progenitors Using Manganese Lines in Supernova Remnants  

CERN Document Server

We propose a new method to measure the metallicity of Type Ia supernova progenitors using Mn and Cr lines in the X-ray spectra of young supernova remnants. We show that the Mn to Cr mass ratio in Type Ia supernova ejecta is tightly correlated with the initial metallicity of the progenitor, as determined by the neutron excess of the white dwarf material before thermonuclear runaway. We use this correlation, together with the flux of the Cr and Mn Kalpha X-ray lines in the Tycho supernova remnant recently detected by Suzaku (Tamagawa et al. 2008) to derive a metallicity of log(Z) = -1.32 (+0.67,-0.33) for the progenitor of this supernova, which corresponds to log(Z/Zsun)= 0.60 (+0.31,-0.60) according to the latest determination of the solar metallicity by Asplund et al. (2005). The uncertainty in the measurement is large, but metallicities much smaller than the solar value can be confidently discarded. We discuss the ...

2008-01-01

262

Recent Progress in CdTe and CdZnTe Detectors  

CERN Document Server

Cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) have been regarded as promising semiconductor materials for hard X-ray and Gamma-ray detection. The high atomic number of the materials (Z_{Cd} =48, Z_{Te} =52) gives a high quantum efficiency in comparison with Si. The large band-gap energy (Eg ~ 1.5 eV) allows us to operate the detector at room temperature. However, a considerable amount of charge loss in these detectors produces a reduced energy resolution. This problem arises due to the low mobility and short lifetime of holes. Recently, significant improvements have been achieved to improve the spectral properties based on the advances in the production of crystals and in the design of electrodes. In this overview talk, we summarize (1) advantages and disadvantages of CdTe and CdZnTe semiconductor detectors and (2) technique for improving energy resolution and photopeak efficiencies. Applications of these imaging detectors in ...

2001-01-01

263

Line intensity enhancements in stellar coronal X-ray spectra due to opacity effects  

CERN Document Server

Context. The I(15.01 A)/I(16.78 A) emission line intensity ratio in Fe XVII has been reported to deviate from its theoretical value in solar and stellar X-ray spectra. This is attributed to opacity in the 15.01 A line, leading to a reduction in its intensity, and was interpreted in terms of a geometry in which the emitters and absorbers are spatially distinct. Aims. We study the I(15.01 A)/I(16.78 A) intensity ratio for the active cool dwarf EV Lac, in both flare and quiescent spectra. Methods. The observations were obtained with the Reflection Grating Spectrometer on the XMM-Newton satellite. The emission measure distribution versus temperature reconstruction technique is used for our analysis. Results. We find that the 15.01 A line exhibits a significant enhancement in intensity over the optically thin value. To our knowledge, this is the first time that such an enhancement has been detected on such a sound statistical basis. We interpret ...

2008-01-01

264

Fundamentals for remote structural health monitoring of wind turbine blades - a pre-project. Annex D - Full-scale test of wind turbine blade, using sensors and NDT  

Energy Technology Data Exchange (ETDEWEB)

A 19.1 metre wind turbine blade was subjected to static tests. The purpose of the test series was to verify the abilities of different types of sensors to detect damage in wind turbine blades. Prior to each of the static test-series an artificial damage was made on the blade. The damage made for each test-series was surveyed during each series by acoustic emission, fiber optic micro bend displacement transducers and strain gauges. The propagation of the damage was determined by use of ultra sonic and X-ray surveillance during stops in the test series. By use of acoustic emission it was possible to measure damage propagation before the propagation was of visible size. By use of fiber optic micro bend displacement transducers and strain gauges it was possible to measure minor damage propagation. By use of both ultra sonic, and X-ray NDT-equipment it were possible to determine the size of propagated damage. (au)

2002-05-01

265

Effects of post-irradiation annealing in alpha-particle bombarded molybdenum  

International Nuclear Information System (INIS)

Structural variations in 39-MeV alpha-particle irradiated (Tsub(irr) = 60 deg C) polycrystalline molybdenum during post-irradiation annealing were studied by X-ray and TEM methods. Despite the high density of irradiation induced defects in the structure of the specimen X-ray measurements showed zero relative lattice parameter change after an irradiation dose of 1.1 x 10"-_2 dpa. However, during the annealing #delta#a/a was changed in the positive range, exhibiting two peaks - at 100 and 300 deg C - whereas the damage structure detected by TEM indicated no changes. Analysis of the results leads to the conclusion that in the range 100 to 250 deg C migration of isolated vacancies and their annihilation at interstitial clusters as well as possible formation of new vacancy clusters occur. The second peak on the #delta#a/a temperature dependence curve is related to the transformation (probably, thermal disintegration) of vacancy ...

266

Compressed-shell integrity measurements in spherical implosion experiments  

International Nuclear Information System (INIS)

The shell integrity near peak compression of spherical implosions using the 60-beam, 30-kJ UV OMEGA laser system [Opt. Commun. 133, 495 (1997)] has been measured. Hot core emission backlights a shell with a thin titanium-doped layer that is imaged at x-ray photon energies above and below the titanium K edge. The x-ray intensity ratio between the two images is related to perturbations in the cold, or absorbing, part of the shell. The measured cold-shell areal-density modulations, integrated over the time of peak compression, are of the order of 25% to 50% with nonuniformity spectra peaked at spatial wavelengths of 30 to 50 #mu#m and with the smallest detectable nonuniformity features extending down to spatial wavelengths of 12 to 15 #mu#m. Hot-shell areal-density modulations of the emitting part of the shell (inner edge) are of the order of 13% to 20%. The measured shell modulations are in agreement with the results of ...

2001-06-01

268

A comparison of the X-ray properties of X Per and gamma Cas  

Energy Technology Data Exchange (ETDEWEB)

The X-ray properties of the main sequence Be stars conclude that they are a widely separated binary system containing an accreting neutron star.

1982-04-01

269

Microprobe RBS analysis of localized processed areas by FIB etching and deposition  

International Nuclear Information System (INIS)

Localized beam-processed areas using chemical reactions induced by a 30 keV Ga"+ focused ion beam (FIB) with and without I_2 (etching) and (CH_3)_3CH_3C_5H_5Pt gases (Pt deposition) have been analyzed using a 300 keV Be"2"+ microprobe with a beam spot size of 50-80 nm. The analyzed results have been compared with energy dispersive X-ray (EDX) analysis using an electron beam. The EDX analysis only indicated incorporated impurities at high fluence such as Ga, Pt and C, while microprobe RBS analysis could detect residual iodine with low concentration which couldn't be detected by EDS analysis because of the lower sensitivity of the EDX analysis for heavy atoms.

2001-07-01

270

A novel graphene nanosheets coated stainless steel fiber for microwave assisted headspace solid phase microextraction of organochlorine pesticides in aqueous samples followed by gas chromatography with electron capture detection  

British Library Electronic Table of Contents (United Kingdom)

In this study, a novel graphene nanosheets (GNSs) coated solid phase microextraction (SPME) fiber was prepared by immobilizing microwave synthesized GNSs on a stainless steel wire. Microwave synthesized GNSs were verified by X-ray diffraction, field emission-scanning electron microscopy (FE-SEM) and transmission electron microscope (TEM). GNS-SPME fiber was characterized using FE-SEM and the results showed the GNS coating was homogeneous, porous, and highly adherent to the surface of the stainless steel fiber. The performance and feasibility of the GNS-SPME fiber was evaluated under one-step microwave assisted (MA) headspace (HS) SPME followed by gas chromatography with electron capture detection for five organochlorine pesticides (OCPs) in aqueous samples. Parameters influencing the extra...

2011-01-01

271

A Preliminary Investigation of the Reinforcement Function of Signal Detections in Simulated Baggage Screening: Further Support for the Vigilance Reinforcement Hypothesis  

Science.gov (United States)

The vigilance reinforcement hypothesis (VRH) asserts that errors in signal detection tasks are partially explained by operant reinforcement and extinction processes. VRH predictions were tested with a computerized baggage screening task. Our experiment evaluated the effects of signal schedule (extinction vs. variable interval 6 min) and visual field complexity (dial vs. baggage x-ray) on search behavior rates. There was a main effect for signal schedule [F (1, 20) = 14.0, p = 0.001, p[subscript rep] = 0.99], but no effects for field complexity or interaction. The VRH suggests that performance errors in visual screening work may be reduced through operant conditioning of search behaviors by intensive management of artificially planted signals. (Contains 1 table and 3 figures.)

2008-12-01

272

Electronic structure of face-centred cubic MoO_2: A comparative study by the full potential linearized augmented plane wave method, X-ray emission spectroscopy and X-ray photoelectron spectroscopy  

International Nuclear Information System (INIS)

X-ray emission spectroscopy (XES) and X-ray photoelectron spectroscopy (XPS) methods were employed in the present paper to investigate the electronic structure of face-centred cubic (fcc) molybdenum dioxide, fcc-MoO_2. For the mentioned compound, the XES O K#alpha# and Mo L#beta#_2_,_1_5 bands reflecting the valence O p- and Mo s,d-like states, respectively, were derived and compared on a common energy scale with the XPS valence-band spectrum. For comparison, the similar experimental studies of the electronic structure were made for a usual orthorhombic form of molybdenum trioxide, MoO_3. Band-structure calculations of fcc-MoO_2 were made using the full potential linearized augmented plane wave (FP-LAPW) method. A rather good agreement of the experimental XES and XPS results and the theoretical FP-LAPW data for the electronic properties of fcc-MoO_2 has been achieved in the present paper. A new near-Fermi sub-band was ...

2008-07-14

273

Comparison of fluorescence in situ hybridisation using peptide nucleic acid probes, Gram stain/acridine orange leukocyte cytospin and differential time to positivity methods for detection of catheter related bloodstream infection in patients after haematopoietic stem cell transplantation  

British Library Electronic Table of Contents (United Kingdom)

Abstract In 46 febrile neutropenic patients who had undergone haematopoietic stem cell transplantation, the fluorescence in situ hybridisation using peptide nucleic acid probes (PNA FISH), Gram stain/acridine orange leukocyte cytospin (Gram/AOLC), and differential time to positivity (DTP) methods were performed for detection of catheter related bloodstream infections (CRBSIs). As compared with the DTP method (which detected 11 patients with CRBSI), the PNA FISH and the Gram/AOLC methods detected ten of 11 CRBSI patients, resulting in a sensitivity, specificity, negative predictive value and positive predictive value of 91%, 100%, 97% and 100%, respectively, for the PNA FISH method as well as for the Gram/AOLC method.

2010-01-01

274

Measurements and elimination of Cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry  

International Nuclear Information System (INIS)

In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber ...

2007-08-21

275

Metrological applications of X-ray waveguide thin film structures in X-ray reflectometry and diffraction  

International Nuclear Information System (INIS)

The effect of resonance, observed in X-ray waveguide layered structures in a characteristic way influences the scattering properties of the films. It is well known that the resonant region in the reflectivity shows a series of minima, usually very deep and extremely narrow. The positions and depths of the minima depend only on X-ray waveguide and quasi X-ray waveguide film structural properties, on the X-ray wavelength and on the incident beam divergence. In the present work we propose and discuss the application of the X-ray waveguide and quasi X-ray waveguide film structures as a tools to experimental evaluation of some quantities related to X-ray reflectometric and diffractometric measurements, like the beam divergence, wavelength, or angular distance. Examples of application of X-ray waveguide as an excellent tool ...

2001-09-23

276

X-ray absorption spectroscopy of bacterial sulfur globules  

Energy Technology Data Exchange (ETDEWEB)

Sulfur K-edge X-ray absorption spectroscopy is a powerful in situ probe of sulfur biochemistry in intact cells and tissues. Under favorable circumstances the technique can provide quantitative information on the chemical identify of the sulfur species that are present in a sample. Prange et al. have recently reported an X-ray absorption spectroscopic study of bacterial sulfur storage globules. Unfortunately there are substantial problems with the experimental technique employed that, they contend, lead to completely erroneous conclusions. In the more recent of their two papers Prange et al. employed a curve-fitting method similar to that used by us (for more than 10 years). In essence, the method employs simply fitting a linear combination of the spectra of standard compounds to that of the unknown, in this case cultures of bacterial cells. This type of analysis can provide quantitative estimates of the individual sulfur types in the sample, ...

2002-08-01

277

Trans-generational radiation-induced chromosomal instability in the female enhances the action of chemical mutagens  

Energy Technology Data Exchange (ETDEWEB)

Genomic instability can be produced by ionising radiation, so-called radiation-induced genomic instability, and chemical mutagens. Radiation-induced genomic instability occurs in both germinal and somatic cells and also in the offspring of irradiated individuals, and it is characterised by genetic changes including chromosomal rearrangements. The majority of studies of trans-generational, radiation-induced genomic instability have been described in the male germ line, whereas the authors who have chosen the female as a model are scarce. The aim of this work is to find out the radiation-induced effects in the foetal offspring of X-ray-treated female rats and, at the same time, the possible impact of this radiation-induced genomic instability on the action of a chemical mutagen. In order to achieve both goals, the quantity and quality of chromosomal damage were analysed. In order to detect trans-generational genomic instability, a total of 4806 ...

2008-04-02

280

Stabilization of synchrotron radiation x-ray beam by MOSTAB  

International Nuclear Information System (INIS)

Monochromator stabilization (MOSTAB) is a feedback control system to stabilize an x-ray beam of synchrotron radiation. It applies a feedback voltage to a piezo electric transducer attached to a double-crystal monochromator. We developed MOSTAB modules and examined their performances using SPring-8 beamlines. The x-ray beam position stabilization using MOSTAB was realized simultaneously with the x-ray beam intensity stabilization. As an example of its application, we performed EXAFS measurement with MOSTAB. (author)

2003-05-01

281

Spin evolution in wind-fed X-ray binaries  

International Nuclear Information System (INIS)

Global angular momentum balance suggests that the neutron stars in Be/X-ray binaries are not spinning in equilibrium. This requires an X-ray lifetime ''approx <'' 10"5 yr, and suggests that there are many 'dead' Be/X-ray binaries in the Galaxy. Some of these may be turned up as millisecond radio pulsars with Be star companions. (author).

285

Possibilities of rayleigh-taylor instability measurement by X-ray phase imaging  

International Nuclear Information System (INIS)

X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging

287

Investigation of morphology and chemical composition of self-organized semiconductor quantum dots and wires by X-ray scattering  

International Nuclear Information System (INIS)

X-ray scattering methods suitable for the investigation of the morphology and chemical composition of self-organized quantum dots and quantum wires are reviewed. Their application is demonstrated in experimental examples showing that a combination of small angle X-ray scattering with high-resolution X-ray diffraction can reveal both the shape and the chemical composition of the self-organized objects. (author)

2001-09-23

288

Ectopic Ureter  

Science.gov (United States)

... such as renal flow scan or a formal kidney X-ray, called an intravenous pyelogram ( IVP ), may help ...

290

Characterization and Source Term Assessments of Radioactive Particles from Marshall Islands Using Non-Destructive Analytical Techniques  

Energy Technology Data Exchange (ETDEWEB)

A considerable fraction of radioactivity entering the environment from different nuclear events is associated with particles. The impact of these events can only be fully assessed where there is some knowledge about the mobility of particle bound radionuclides entering the environment. The behavior of particulate radionuclides is dependent on several factors, including the physical, chemical and redox state of the environment, the characteristics of the particles (e.g., the chemical composition, crystallinity and particle size) and on the oxidative state of radionuclides contained in the particles. Six plutonium-containing particles stemming from Runit Island soil (Marshall Islands) were characterized using non-destructive analytical and microanalytical methods. By determining the activity of {sup 239,240}Pu and {sup 241}Am isotopes from their gamma peaks structural information related to Pu matrix was obtained, and the source term was revealed. Composition and elemental distribution ...

2005-06-11

291

Solution state hybridization detection using time-resolved fluorescence anisotropy of quantum dot-DNA bioconjugates  

British Library Electronic Table of Contents (United Kingdom)

In this Letter, we demonstrate the application of time-resolved fluorescence anisotropy measurements to detect solution state hybridization of streptavidin conjugate (CdSe)ZnS quantum dots (QD). The study was performed on samples containing 10nM QD incubated with 800nM DNA. We show that the rotational correlation time of QD-DNA constructs increases significantly upon hybridization with values of 330ns (QD-ssDNA) and 1.3ms (QD-dsDNA), corresponding to a diameter of 14nm and 23nm respectively. The present study opens a new modality for hybridization detection using quantum dots.

2010-01-01

292

Selective adsorption of uranium on activated charcoal from electrolytic aqueous solutions  

Energy Technology Data Exchange (ETDEWEB)

Adsorption of uranium onto various solids is important from purification, environmental, and radioactive waste disposal points of view. Adsorption of uranium on activated charcoal has been studied as a function of shaking time, amount of adsorbent, pH, concentration of adsorbate, and temperature. Uranium adsorption obeys the Langmuir isotherm. {Delta}H{degrees} and {Delta}S{degrees} were calculated from the slope and intercept of plots ln K{sub D} vs 1/T. The influence of different anions and cations on uranium adsorption has been examined. The adsorption of other metal ions on activated charcoal has been studied under specified conditions to check its selectivity; consequently, uranium was removed from Cs, Ba, Zn, and Co. More than 98% adsorbed uranium on activated charcoal can be recovered with 65 ml of 3 M HNO{sub 3} solution. A wavelength dispersive x-ray fluorescence spectrometer was used for measuring uranium concentration.

1992-02-01

293

Preparation of CaWO{sub 4}:Ln{sup 3+} SiO{sub 2} (Ln=Tb, Dy and Ho) nanoparticles by a combustion reaction and their optical properties  

Energy Technology Data Exchange (ETDEWEB)

The CaWO{sub 4}:Ln{sup 3+} SiO{sub 2} (Ln=Tb, Dy and Ho) nanoparticles were synthesized via a combustion process at 800 {sup o}C, using citric acid as chelating agent and fuel, ammonium nitrate as fuel, boric acid as flux material and silica as supports. The persistent phosphor nanoparticles were characterized by X-ray diffraction (XRD), reflectance UV-vis and fluorescence spectroscopy (PL) and transmission electron microscopy (TEM) techniques. XRD patterns indicated that crystalline calcium tungstate with scheelite structure was produced. The reflectance UV-vis spectra showed the broad absorption band of WO{sub 4}{sup 2-} groups and the PL spectra showed the WO{sub 4}{sup 2-} wide excitation band, broad emission band of WO{sub 4}{sup 2-} and characteristic emissions of Ln{sup 3+} ions. The average particle sizes were determined by TEM, which are about 50 nm.

2010-11-15

294

Preparation of CaWO_4:Ln"3"+ SiO_2 (Ln=Tb, Dy and Ho) nanoparticles by a combustion reaction and their optical properties  

International Nuclear Information System (INIS)

The CaWO_4:Ln"3"+ SiO_2 (Ln=Tb, Dy and Ho) nanoparticles were synthesized via a combustion process at 800 "oC, using citric acid as chelating agent and fuel, ammonium nitrate as fuel, boric acid as flux material and silica as supports. The persistent phosphor nanoparticles were characterized by X-ray diffraction (XRD), reflectance UV-vis and fluorescence spectroscopy (PL) and transmission electron microscopy (TEM) techniques. XRD patterns indicated that crystalline calcium tungstate with scheelite structure was produced. The reflectance UV-vis spectra showed the broad absorption band of WO_4"2"- groups and the PL spectra showed the WO_4"2"- wide excitation band, broad emission band of WO_4"2"- and characteristic emissions of Ln"3"+ ions. The average particle sizes were determined by TEM, which are about 50 nm.

2010-11-01

295

Palladium(II) and platinum(II) saccharinate complexes containing pyridine and 3-acetylpyridine: Synthesis, crystal structures, fluorescence and thermal properties  

British Library Electronic Table of Contents (United Kingdom)

New palladium(II) and platinum(II) complexes of saccharinate (sac), trans-[Pd(py)"2(sac)"2] (1), cis-[Pt(py)"2(sac)"2] (2), trans-[Pd(3-acpy)"2(sac)"2] (3) and cis-[Pt(3-acpy)"2(sac)"2] (4) (py=pyridine and 3-acpy=3-acetylpyridine) have been synthesized. Elemental analysis, UV-Vis, IR, NMR and TG/DTA characterizations have been carried out. The structures of 1-4 were determined by X-ray diffraction. The palladium(II) and platinum(II) ions are coordinated by two N-bonded sac ligands, and two nitrogen atoms of py or 3-acpy, forming a distorted square-planar geometry. The palladium(II) complexes (1 and 3) are trans isomers, while the platinum(II) complexes (2 and 4) are cis isomers. The mononuclear species in the solid state are connected by weak intermolecular C-H...O hydrogen bonds, C-H...@...

2011-01-01

296

Measuring instrument for radiometric monitoring of solids and heavy metals in water  

International Nuclear Information System (INIS)

A combination of measuring instruments, consisting of a Beta-Sedimeter and a radionuclide X-ray fluorescence instrument, is described. With the Beta-Sedimeter the C-14-radiation is measured. Through direct irradiation with photons of a Pu238-source in an ancillary irradiation chamber and energy dispersing measurement of the K- and L-radiation resp. of the excited heavy metals with the aid of a Si(Li)-semiconductor detector and a 4-channel analyzer the heavy metal concentrations of the heavy metals Zn, Cr, Ni and Pb are determined. For the determination of cadmium the indirect excitation with Am-241 and Dy-targets is described. The system produces records and operates fully automatically in a step-by-step mode with a testing cycle of 45 minutes. In connection with the process monitoring of the wastewater from a zinc plating plant during a period of 8 months the concentration of the solid material and of the metals Cr and Zn, which were ...

1979-01-01

297

Development of highly reliable screening by using x-ray fluorescence spectrometry. Applications to determine lead in tin plated and tin-bismuth plated samples  

International Nuclear Information System (INIS)

A highly reliable screening method was developed for the determination of lead in tin plated layers and tin-bismuth plated layers. The contents of lead in the layers of the various samples were determined by inductively coupled plasma optical emission spectrometry. The calibration curve for lead in the tin and tin-bismuth plated layers by using WD-XRF exhibited linear correlation from 130 #mu#g/g to 2070 #mu#g/g. Calibration curve of lead normalized with Pb-L#alpha#/Sn-K#alpha# intensity was more linear, and this method was possible to evaluate very small sample. The calibration curve for lead in the tin plated layers by using ED-XRF was good linearly, but it for lead in the tin-bismuth plated layers was affected by Pb-L#alpha# spectrum and Bi-L#alpha# spectrum overlap each other. It was effective for decreasing affect of Bi-L#alpha# spectrum by using curve fitting method. (author)

2009-03-01

298

An Investigation of the Relationship Between Tritium in Groundwater and the Dendrochronology of Tritium in Trees at the Savannah River Site. Final report  

Energy Technology Data Exchange (ETDEWEB)

This project was supported through ERDA to demonstrate that the temporal distribution of tritium can be documented by the analysis of bound hydrogen in annual tree-ring samples. The project focuses on two sample locations at the Savannah River Site (SRS), a nuclear material production facility located in Aiken, SC. The SRS provided samples of cross-sections from a single tree that were to be pooled together for analysis. Annual tree-rings were identified in each cross-section sample and separated for the period 1954 to 1993. These annual samples were ground and chemically treated to separate the hollocellulose fraction of the wood, then subsequently combusted and the resulting water counting using low-level liquid scintillation counting equipment. Additionally, the ground annual tree-rings were gamma-counted to determine any temporal variation in radionuclide activity and analyzed with x-ray fluorescence to find any temporal variation in ...

1995-03-21

299

Are Optically-Selected Quasars Universally X-Ray Luminous? X-Ray/UV Relations in Sloan Digital Sky Survey Quasars  

CERN Document Server

We analyze archived Chandra and XMM-Newton X-ray observations of 536 Sloan Digital Sky Survey (SDSS) Data Release 5 (DR5) quasars (QSOs) at 1.7 <= z <= 2.7 in order to characterize the relative UV and X-ray spectral properties of QSOs that do not have broad UV absorption lines (BALs). We constrain the fraction of X-ray weak, non-BAL QSOs and find that such objects are rare; for example, sources underluminous by a factor of 10 comprise $\\la$2% of optically-selected SDSS QSOs. X-ray luminosities vary with respect to UV emission by a factor of $\\la$2 over several years for most sources. UV continuum reddening and the presence of narrow-line absorbing systems are not strongly associated with X-ray weakness in our sample. X-ray brightness is significantly correlated with UV emission line properties, so that relatively X-ray weak, non-BAL ...

2008-01-01

300

Future of X-ray phase imaging in medical imaging technology  

International Nuclear Information System (INIS)

Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)

2007-04-01

301

PKH26 as a fluorescent label for live human umbilical mesenchymal stem cells  

British Library Electronic Table of Contents (United Kingdom)

To determine whether PKH26 labeling affects the morphologies, phenotypes, proliferation, and secretion abilities of human umbilical mesenchymal stromal cells (HUMSCs) were investigated. Isolated HUMSCs were labeled with PKH26, and cell morphology was observed under microscope. Cell cycle, apoptotic cell death, expression of PKH26, and the proliferation rate were evaluated. Additionally, fluorescence intensity of PKH26 labeling at different passage times was quantified. There were no detectable differences in cell morphology, cell growth, and proliferation rate after PKH26 labeling. In addition, fluorescence intensity of PKH26 labeling was gradually reduced with increase of the passage times. The PKH26 labeling disappeared after passage six times. In summary, PKH26 labeling is a safe and ef...

2011-01-01

302

Detection of Fluorescence for Lanthanides in LiCl-KCl Molten Salt Medium  

Energy Technology Data Exchange (ETDEWEB)

In the electrorefining step of the pyrochemical process, actinide ions dissolved in the LiCl-KCl eutectic salt are recovered as pure actinide metals at a cathode for a re-use as a nuclear fuel from the aspect of its nonproliferation of the nuclear fuel cycles. The lanthanide species dissolved in the LiCl-KCl eutectic salt play an important role in an effective metal purification during the electrorefining step, so it is necessary to understand the chemical and physical behaviors of lanthanides in molten salt. The in situ spectroscopic measurement system and studies according to temperature changes are essential for better understandable information. To our knowledge, the absorption studies of lanthanides at high temperatures have been reported before, but the fluorescence studies of those at high temperature are not reported yet. We will discuss here the fluorescence behaviors of lanthanides in LiCl-KCl molten salt medium according to a ...

2007-10-15

303

Detection of Fluorescence for Lanthanides in LiCl-KCl Molten Salt Medium  

International Nuclear Information System (INIS)

In the electrorefining step of the pyrochemical process, actinide ions dissolved in the LiCl-KCl eutectic salt are recovered as pure actinide metals at a cathode for a re-use as a nuclear fuel from the aspect of its nonproliferation of the nuclear fuel cycles. The lanthanide species dissolved in the LiCl-KCl eutectic salt play an important role in an effective metal purification during the electrorefining step, so it is necessary to understand the chemical and physical behaviors of lanthanides in molten salt. The in situ spectroscopic measurement system and studies according to temperature changes are essential for better understandable information. To our knowledge, the absorption studies of lanthanides at high temperatures have been reported before, but the fluorescence studies of those at high temperature are not reported yet. We will discuss here the fluorescence behaviors of lanthanides in LiCl-KCl molten salt medium according to a ...

2007-10-01

304

A dual-emissive-materials design concept enables tumour hypoxia imaging  

British Library Electronic Table of Contents (United Kingdom)

Luminescent materials are widely used for imaging and sensing owing to their high sensitivity, rapid response and facile detection by many optical technologies. Typically materials must be chemically tailored to achieve intense, photostable fluorescence, oxygen-sensitive phosphorescence or dual emission for ratiometric sensing, often by blending two dyes in a matrix. Dual-emissive materials combining all of these features in one easily tunable molecular platform are desirable, but when fluorescence and phosphorescence originate from the same dye, it can be challenging to vary relative fluorescence/phosphorescence intensities for practical sensing applications. Heavy-atom substitution alone increases phosphorescence by a given, not variable amount. Here, we report a strategy for modulating ...

2009-01-01

305

Upper Limits from HESS Observations of AGN in 2005-2007  

CERN Document Server

Very high energy (VHE; >100 GeV) observations of a sample of selected active galactic nuclei (AGN) were performed between January 2005 and April 2007 with the High Energy Stereoscopic System (HESS), an array of imaging atmospheric-Cherenkov telescopes. Significant detections are reported elsewhere for many of these objects. Here, integral flux upper limits for twelve candidate very high energy (VHE; >100 GeV) gamma-ray emitters are presented. In addition, results from HESS observations of four known VHE-bright AGN are given although no significant signal is measured. For three of these AGN (1ES 1101-232, 1ES 1218+304, and Mkn 501) simultaneous data were taken with the Suzaku X-ray satellite.

2007-01-01

306

Studies of basic parameters of electron-counting detection  

International Nuclear Information System (INIS)

Measurements have been made of certain parameters relevant to the operation of electron-counting detectors. An experimental chamber consisting of a uniform-field drift tube and a coaxial proportional counter thas been employed to obtain data, at very low drift fields (E/p<0.02 V/cm Torr), on electron mobility and lifetimes in a range of gas mixtures. These mixtures included argon, methane, nitrogen and carbon dioxide. Measurements of single-electron spectra showed that, unexpectedly for the standard gas mixtures employed, useful departure from an exponential spectrum was not possible without the production of cathode secondaries. Although the present studies employed only the counter electrical signal the information obtained should be directly relevant to the operation of practical light-pulse systems. Examples of electron-counting spectra for soft X-rays are shown. (orig.).

1990-05-21

307

Morphology evolution of Ir-Nb-X (X = Hf, Ta, or Ti) ternary alloys  

Energy Technology Data Exchange (ETDEWEB)

The microstructure evolution of nine samples from three Ir-base ternary systems, Ir-Nb-Hf, Ir-Nb-Ta, and Ir-Nb-Ti, was investigated by microstructure observation using scanning electron microscopy (SEM), composition map-analysis using electron probe microscopy analysis (EPMA), and phase determination using X-ray diffraction (XRD) patterns. The fcc/L1{sub 2} two-phase structure was detected in all the samples. Lattice misfits between fcc and L1{sub 2} phases were calculated. Ir-Nb-Ta and Ir-Nb-Ti alloys exhibited a microstructure quite similar to that of Ni-base superalloys, and the cuboidal L1{sub 2} precipitates in Ir-Nb-Ta and Ir-Nb-Ti alloys could maintain up to 1900 {sup o}C.

2007-01-31

308

Identification of fatigue damage in cortical bone by diffraction enhanced imaging  

International Nuclear Information System (INIS)

In an effort to explore Diffraction Enhanced Imaging of bone tissue, experiments were performed to determine if it was possible to use Diffraction Enhanced Imaging to detect microdamage in bovine cortical bone. Measurements were made at the National Synchrotron Light Source where pre- and post-fatigue rocking curve widths of the bone were studied. The rocking curve widths were then compared. Since no consistent pattern of narrowing or broadening of the rocking curve emerged, it is likely that the ultra-small-angle X-ray scattering present in the bone overshadowed any additional changes to rocking curve caused by microdamage of the bone. Larger bone structures were able to be visualized which suggests that microdamage may be visualized with a higher resolution detector.

2005-08-11

309

Effects of manganese doping on properties of sol-gel derived biphasic calcium phosphate ceramics  

British Library Electronic Table of Contents (United Kingdom)

We have investigated the effect of manganese (Mn) doping on properties of nanosized biphasic calcium phosphate powders and their dense bodies. Manganese levels of 0.6, 1.3, 1.9, 4.3, 7.0 and 11.9at.% were successfully incorporated into biphasic calcium phosphate via a sol-gel route. The prepared powders were calcined at temperatures of 500-1200^oC. The X-ray diffraction analysis revealed that a mix phase comprising of hydroxyapatite and @b-tricalcium phosphate were present, however the content of each phases in the structure was affected by the Mn content. The studies found that the largest portion of @b-tricalcium phosphate was detected at 4.3at.% Mn doping. The incorporation of Mn has also greatly increased the crystallinity of the biphasic calcium phosphate powder due to progressive den...

2011-01-01

310

Determination of Proper Peaking Time for Ultra Lege detector at Medium Energies  

International Nuclear Information System (INIS)

Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the optimum peaking time for particular detector systems is important. For this purpose, pure Se and Zn elements were excited by 59.5 keV ?-rays from a 50 mCi 241Am annular radioactive source in this study. The characteristic x-rays emitted from pure Se and Zn elements were detected by using an ultra low energy Ge (Ultra-LEGe) detector connecting Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by HM 203-7 oscilloscope connecting amplifier. The proper peaking time for ultra low energy germanium detector (Ultra-LEGe) is determined about 4 ?s.

2008-08-25

311

Computed Tomography of the spine in multiple myeloma  

International Nuclear Information System (INIS)

Computed Tomography (CT) of the spine was performed on 17 patients with myeloma in order to assess the role of the technique in recognizing and evaluating the extent of the lesions. Myelomatous lesions followed two patterns at CT: first of all, multiple focal lesions, whose density is either solid, liquid, or fatty; second, an extensive pattern involving the spongiosa of the vertebra, including the posterior arch. CT detected more lesions than conventional radiology; furthermore, the extent of the lesions was much better demonstrated by CT. CT should thus be performed: a) in case of pain and/or neurological findings in negative radiological examinations; b) to evaluate the extent of myelomatous lesions (mainly in the spine); c) in solitary myeloma CT may be performed on different bone segments with clinical symptomatology but normal X-ray findings.

1988-01-01

312

Biosorption of lead by citrobacter freundii immobilized on hazelnut shells  

Energy Technology Data Exchange (ETDEWEB)

Biosorption of lead from aqueous solutions by living and immobilized cell of C. freundii was examined as a function of metal concentration in a batch laboratory bioreactor. Lead concentrations were analyzed using Atomic Absorption Spectrophotometer (AAS). X-ray Energy Dispersion (EDX) analyses were made in order to determine the accumulation of lead on the cells and shell surfaces. Before and after the experiments the biomaterials and adsorbents were examined by Scanning Electron Microscopy (SEM). Biosorption was detected over a range of initial lead concentrations from 25{times}10{sup -3} to 200{times}10{sup -3} kg/m{sup 3}. 15 refs., 4 figs.

1996-12-31

313

Behavior of triterpenes from Maytenus aquifolium Martius ('espinheira santa') upon X- and gamma-rays irradiation  

International Nuclear Information System (INIS)

The behavior of the triterpenes friedelin and friedelan-3-ol, contained on the leaves of Maytenus aquifolium Martius (Celastraceae), upon several doses of X- and #gamma#-rays (10 to 100 kGy), was investigated by high resolution gas chromatography (HRGC) and high resolution gas chromatography -mass spectrometry (HRGC-MS). The friedelin content has not changed with #gamma#-irradiation, but the content of friedelan-3-ol decreased around 17% at doses of 10, 20 and 40 kGy and around 27% at doses of 60, 80 and 100 kGy. The levels of both triterpenes remained unchanged even at higher X-ray doses. Lupen-3-one was detected by HRGC-MS. (author).

314

X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography  

International Nuclear Information System (INIS)

Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a ...

2002-03-01

315

Gravitational waves interferometer and the VIRGO project  

CERN Document Server

Radio, optical and X-rays telescopes are improving our knowledge of deep space. All these telescopes detect electromagnetic radiation at various frequencies. But a different kind of radiation is generated in the deeper space; it is the gravitational one. Gravitational waves change the space-time metric. As a consequence, GW telescopes should detect an extremely small strain (h < 10/sup -21/) of the geometry of a reference frame; if the frame has a reference dimension (L) of some kilometers, the deformation amplitude ( Delta L = h * L) is limited to 10/sup -16/ meters. Laser interferometers are the most suitable devices to make precise measurements of distances. Their resolution is limited by the laser wavelength ( lambda = 10/sup -6/ meters) and by the light wave-shift detection capability ( Delta Phi = 1 ppb). These theoretical limits are strongly degraded by different noise sources, which reduce ...

2002-01-01

316

Uranium isotopic assay instrument  

International Nuclear Information System (INIS)

Full text: The isotopic assay instrument under development at Pacific Northwest National Laboratory (PNNL) is capable of rapid prescreening to detect small and rare particles containing high concentrations of uranium in a heterogeneous sample. The isotopic measurement concept is based on laser vaporization of solid samples followed by sensitive isotope-specific detection using either uranium atomic fluorescence emission or uranium atomic absorbance. Both isotopes are measured concurrently, following a single ablation laser pulse using two external-cavity violet diode lasers. The simultaneous measurement of both isotopes enables the correlation of the fluorescence and absorbance signals on a shot-to-shot basis. This measurement approach demonstrated negligible channel crosstalk between isotopes. Scanning the heterogeneous samples provides high-resolution imagery of sample isotopic ...

2006-10-16

317

Determination of radiation exposure and significance of its influential factors for X-rayed children in the GDR  

International Nuclear Information System (INIS)

After having discussed the peculiarities of children in X-ray diagnosis the application of the effective as well as the mean equivalent doses as to the determination of the radiation exposure in children is represented. In using computerized tomograms to determine position and extent of an organ the exposure by repeated X-raying was calculated referring to the entrance dose. Entrance dose measurements for all types of X-ray examination in hospitals and ascertainments of the frequency of radiograms in 20 X-ray departments were used to determine per capita and collective doses, resp., in several age groups. Alltogether, the per capita dose of children in the GDR amounts to 30% of that of adults. Conclusions were drawn as to taking measures to further reduction of radiation exposure: (1) Technical measures, such as positioning of patients, shielding of organs, quality assurance; (2) elaboration of ...

1988-01-01

318

Broad-band hard X-ray reflectors  

DEFF Research Database (Denmark)

Interest in optics for hard X-ray broad-band application is growing. In this paper, we compare the hard X-ray (20-100 keV) reflectivity obtained with an energy-dispersive reflectometer, of a standard commercial gold thin-film with that of a 600 bilayer W/Si X-ray supermirror. The reflectivity of the multilayer is found to agree extraordinarily well with theory (assuming an interface roughness of 4.5 Angstrom), while the agreement for the gold film is less, The overall performance of the supermirror is superior to that of gold, extending the band of reflection at least a factor of 2.8 beyond that of the gold, Various other design options are discussed, and we conclude that continued interest in the X-ray supermirror for broad-band hard X-ray applications is warranted.

1997-01-01

319

Kinetics of Pd/sub 2/Si layer growth measured by an x-ray diffraction technique  

Science.gov (United States)

An x-ray diffraction approach has been developed for determination of the kinetics of growth of Pd/sub 2/Si layers. Epitaxial Pd/sub 2/Si films were grown on Si(111) substrates over a temperature range of 160-222/sup 0/C by a solid-state reaction between the substrates and the Pd overlayers. The parabolic rate equation was verified and rate constants showed Arrhenius behavior with an activation energy E/sub a/ = 1.06 eV and prefactor k/sub 0/ = 7 x 10/sup -4/ cm/sup 2//s. The low value of E/sub a/ suggests a short-circuit diffusion mechanism. It is reasonable to expect that impurities and microstructure may play important roles in the growth process. Impurity levels in the specimens were evaluated by analytic techniques suited to thin-film study: Rutherford backscattering spectrometry, secondary ion mass spectrometry, and Auger electron spectrometry. No impurities were present at concentrations approaching 1 at. %. Some O, C, and F were ...

1986-05-15

320

Corrosion product role on the inhibition of Zn alloy electrodeposit corrosion  

Energy Technology Data Exchange (ETDEWEB)

Electrodeposited Zn alloys with Fe group metals are known to be more resistant than pure Zn. However, the role of the corrosion products on the corrosion inhibition is not considered up to date. The aim of the present work was to examine the composition of corrosion products, which form on the Zn and Zn alloy surfaces under atmospheric corrosion conditions up to 3 year of exposure, trying to correlate it with the differences in their corrosion resistance. Zn corrosion products have been characterized by X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). Corrosion film composition was determined to depend on the sample exposure she, as well on the coating type. During the initial exposure stages oxide film was found to be the principal reaction product (XPS data), which in marine station consists from hydroxide phase exceptionally, while in urban one, contain up to 6-12 % of oxide. Succeeding corrosion products (XRD data) in ...

1998-12-31

321

Fluorimetric study of the interaction between nicotinamide adenine dinucleotide phosphate and tetracycline-europium complex and its application  

Energy Technology Data Exchange (ETDEWEB)

A new spectrofluorimetric method was developed for the determination of trace amount of nicotinamide adenine dinucleotide phosphate (NADP). Using europium (Eu{sup 3+})-tetracycline (TC) complex as a fluorescent probe, in the buffer solution of pH 7.60. NADP can remarkably enhance the fluorescence intensity of the Eu{sup 3+}-TC complex at {lambda} = 612 nm and the enhanced fluorescence intensity of Eu{sup 3+} ion is in proportion to the concentration of NADP. Optimum conditions for the determination of NADP were also investigated. The dynamic range for the determination of NADP is 4.4 x 10{sup -7} to 2.2 x 10{sup -6} mol l{sup -1} with detection limit of 6.9 x 10{sup -8} mol l{sup -1}. This method is simple, practical and relatively free interference from coexisting substances and can be successfully applied to determination of NADP in synthetic water samples and in serum samples. Moreover, the ...

2005-09-06

322

Anode length optimization in a modified plasma focus device for optimal x-ray yields  

International Nuclear Information System (INIS)

The effect of anode length and operating gas pressure on the x-ray emission from a nitrogen-filling modified plasma focus device has been investigated. The time-resolved investigation of x ray was carried out by using a five-channel photodiode x-ray spectrometer. The maximum x-ray yield is seen to increase with the increase in the anode length from 110 to 125 mm. Further increase in the anode length to 130 mm causes the x-ray yields to decrease. The highest x-ray yield of 4.5 J into 4#pi# sr was found for 125 mm anode length, which is 0.2% of the input energy. The average x-ray photon energy was estimated by using half-value thickness method and found to be 8.4 keV. The electron temperature of the plasma was estimated to be around 3 keV by x-ray intensity ratio method. The space-resolved ...

2006-01-01

323

X-ray dosimetry of TlGaSe_2 single crystals  

International Nuclear Information System (INIS)

TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. ...

324

Tissue oxygenation in a murine SCC VII tumor after X-ray irradiation as determined by EPR spectroscopy  

UK PubMed Central (United Kingdom)

PurposeThe goal of this study was to clarify the dynamics of tumor oxygen (partial pressure of oxygen, pO2) in SCC VII murine tumors in mice after X-ray...Full Text Available

2008-03-01

325

Subacute neuropathological effects of microplanar beams of x-rays from a synchrotron wiggler.  

UK PubMed Central (United Kingdom)

Microplanar beam radiation therapy has been proposed to treat brain tumors by using a series of rapid exposures to an array of parallel x-ray beams, each beam having uniform microscopic thickness and...Full Text Available

1995-09-12

326

Small-Angle X-ray Scattering of Reduced Ribonuclease A: Effects of Solution Conditions and Comparisons with a Computational Model of Unfolded Proteins  

UK PubMed Central (United Kingdom)

The disulfide-reduced form of bovine ribonuclease A (RNAse A), with the Cys thiols irreversibly blocked, was characterized by small-angle x-ray scattering (SAXS). To help resolve the conflicting...Full Text Available

2008-04-11

327

Radiation exposure due to X-rays of the hip joint in babies  

International Nuclear Information System (INIS)

Exact anatomic knowledge about the location of the gonads and the application of corresponding measures of radiation protection are the preconditions for an efficient reduction of the danger of a possible genetic damage as a result of radiation exposition during X-ray examination of the hip joint of newborns. (VJ).

328

PIXE analysis of GaAs and ZnSe  

Energy Technology Data Exchange (ETDEWEB)

The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K{sub {alpha}} X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K{sub {alpha}} X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be satisfied in order that the ...

1990-01-01

329

PIXE analysis of GaAs and ZnSe  

International Nuclear Information System (INIS)

The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K_#alpha# X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K_#alpha# X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be satisfied in order that the ...

1989-06-01

330

Numerical optimization of spherical variable-line-spacing grating X-ray spectrometers  

UK PubMed Central (United Kingdom)

Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and...Full Text Available

2011-03-01

331

Noise Characterization of Polycrystalline Silicon Thin Film Transistors for X-ray Imagers Based on Active Pixel Architectures  

UK PubMed Central (United Kingdom)

An examination of the noise of polycrystalline silicon thin film transistors, in the context of flat panel x-ray imager development, is reported. The study was conducted in the spirit of exploring...Full Text Available

2008-01-01

332

Method of describing dose distributions in computer design of teleradiotherapy  

International Nuclear Information System (INIS)

Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.

333

Measurements of accurate x-ray scattering data of protein solutions using small stationary sample cells  

UK PubMed Central (United Kingdom)

In this paper, we report a method of precise in situ x-ray scattering measurements on protein solutions using small stationary sample cells. Although reduction in the radiation damage...Full Text Available

2009-01-01

334

Magnetic fields of x-ray pulsars  

Energy Technology Data Exchange (ETDEWEB)

An analytic model of magnetic torques applied to an accreting neutron star is employed to evaluate the magnetic dipole moments of x-ray pulsars. A new type of close binary system containing a neutron star is suggested.

1982-09-01

335

Grating-based X-ray phase imaging using multiline X-ray source  

International Nuclear Information System (INIS)

Differential phase-contrast X-ray imaging has been performed in a Talbot-Lau configuration, where a multiline X-ray source was used instead of a combination of a hard-X-ray multiple slit and a normal focus X-ray generator. When the multiple slit is used, a high aspect ratio structure is needed and slit width should be below 10 ?m for its function. The fabrication and use of such a multislit can be omitted using the presented configuration. The multiline X-ray source was developed by making grooves on a tungsten rotating anode, which was irradiated by an electron beam to generate X-rays. An array of 10?m line sources with a pitch of 30?m was formed and combined with a 4.5 ?m pitch phase grating and a 5.3 ?m pitch amplitude grating to generate differential phase contrast. With a total exposure time of 40 s, a differential phase image depicting cartilages was ...

2009-07-01

336

Experimental X-ray intensity ratio L#beta#/L#alpha#  

International Nuclear Information System (INIS)

Experimental, relative intensities for the components of L X-ray were collected from literature, and atomic-number dependency of L#beta#/L#alpha# has been found. (author).

1980-01-01

337

Complex Spatio-Spectral Structure of Diffuse X-Ray emission in the ...  

Science.gov (United States)

SN 1987A: Soft X-Ray Intensity Ratio. 2002-12 to 2000-12. 2005-7 to 2002-12. Contours: 2002-12. (0.5 2 keV). (0.5 2 keV). Contours: 2005-7 ...

338

Chemical effects on K x-ray intensity ratios in chromium compounds  

International Nuclear Information System (INIS)

K_#beta#/ K_#alpha# x-ray intensity ratio of chromium were measured in different chromium compounds. The results show the variation of the intensity ratio as a function of the chemical environment around the metal ion. (author)

2003-02-10

339

Characterization and catalytic oxidation activity of uranium-bismuth mixed oxides  

International Nuclear Information System (INIS)

Bi-U mixed oxides were synthesized by two methods and characterized by X-ray diffraction and X-ray photoelectron spectroscopy. The samples were tested for the catalytic oxidation of carbon monoxide by oxygen. A stepwise redox mechanism consistent with the kinetic results is proposed. (orig.).

340

APOD: 2002 July 11 - M51: X Rays from the Whirlpool  

Science.gov (United States)

picture will download the highest resolution version available. M51: X-Rays from the Whirlpool Credit: A. Wilson (UMD) et al., CXC, NASA Explanation: Fresh from yesterday's...

2011-10-07

341

A comparison of iterative algorithms and a mixed approach for in-line x-ray phase retrieval  

UK PubMed Central (United Kingdom)

Previous studies have shown that iterative in-line x-ray phase retrieval algorithms may have higher precision than direct retrieval algorithms. This communication compares three iterative phase...Full Text Available

2009-08-15

342

Probing isolated compact remnants with microlensing  

CERN Document Server

We consider isolated compact remnants (ICoRs), i.e. neutrons stars and black holes that do not reside in binary systems and therefore cannot be detected as X-ray binaries. ICoRs may represent $\\sim\\,5$ percent of the stellar mass budget of the Galaxy, but they are very hard to detect. Here we explore the possibility of using microlensing to identify ICoRs. In a previous paper we described a simulation of neutron star evolution in phase space in the Galaxy, taking into account the distribution of the progenitors and the kick at formation. Here we first reconsider the evolution and distribution of neutron stars and black holes adding a bulge component. From the new distributions we calculate the microlensing optical depth, event rate and distribution of event time scales, comparing and contrasting the case of ICoRs and "normal stars". We find that the contribution of remnants to optical depth is slightly lower than without ...

2010-01-01

343

Observing the Sunyaev-Zel'dovich Effect Closer to Home  

CERN Document Server

Hot gas trapped in a dark matter halo will produce a decrement in the surface brightness of the microwave background, the Sunyaev-Zel'dovich (SZ) effect. While massive clusters produce the strongest central SZ decrements, we point out that a local galaxy halo, specifically the halo of M31, may be one of the brightest integrated SZ sources in the sky. For various realistic gas distributions consistent with current X-ray limits, we show that the integrated SZ decrement from M31 will be comparable to decrements already detected in more distant sources, provided its halo contains an appreciable quantity of hot gas. A measurement of this decrement would provide direct information on the mass, spatial distribution and thermodynamic state of hot gas in a low-mass halo, and could place important constraints on current models of galaxy formation. Detecting such an extended (~ 10 degree), low-amplitude signal will be challenging, but ...

2003-01-01

344

Non-destructive testing of refractories, especially AZS materials, with ultrasound, microwaves and {gamma}-radiation  

Energy Technology Data Exchange (ETDEWEB)

In principle four different methods (ultrasound, microwaves, {gamma}-radiation and x-rays) are available for the non-destructive testing of refractories. Three of these methods, i.e. ultrasound, microwaves and {gamma}-radiation, are in use by different producers of AZS materials to carry out the quality control of their products. This paper will compare the three methods on the basis of the physical properties, present the existing devices, and show the advantages as well as the limits of the different methods. {gamma}-radiography, the oldest method in use, has one main disadvantage, which is the requirement of protection against radioactive radiation. Furthermore, while cracks and cavities can be detected with this method, structural changes can not be monitored. Therefore, the ultrasonic method was developed that allows to detect variations of porosity and grain size as well as cracks and voids when the ultrasonic ...

1995-08-01

345

Imaging properties of the Medipix2 system exploiting single and dual energy thresholds  

CERN Document Server

Low noise, high resolution and high dose efficiency are the common requirements for most X-ray imaging applications. Especially in medical applications the dose efficiency is a necessity for detector systems. We present the imaging performance of the Medipix2 readout chip bump bonded to a 300 mu m thick Si detector as a function of the detection threshold, a free parameter not available in conventional integrating imaging systems. Spatial resolution has been measured using the modulation transfer function (MTF) and it varies between 8.2 Ip/mm and 11.0 Ip/mm at 70%. An associated measurement of noise power spectrum (NPS) permits us to derive the detective quantum efficiency (DQE) which can be as a high as 25.5 % for a broadband incoming spectrum. The influence of charge diffusion in the sensor together with threshold variation in the readout chip is discussed. Although the Medipix2 system is used in photon counting mode with ...

2006-01-01

348

Superconducting properties of metallic superlattices  

Energy Technology Data Exchange (ETDEWEB)

The preparation by sputtering of artificial metallic superlattices is described, as are the results of x-ray structural determinations. Tunneling and resistivity measurements on these materials are reported.

1987-01-01

349

Plasma diagnostics in the optical and X-ray regions on the plasma focus device PF-4 (TULIP)  

International Nuclear Information System (INIS)

... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,

2006-09-11

350

Hard X-ray phase imaging and tomography using a grating interferometer  

International Nuclear Information System (INIS)

An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.

2007-07-01

351

Experimental study of X-ray vidicon  

International Nuclear Information System (INIS)

(1972). USSR Sviryakin, DI Manets, AI Kolupaev, AN v. 213 p. 111-114.

353

Electron-induced luminescence and x-ray spectrometer development: progress report  

Science.gov (United States)

The progress in the development of a surface analysis tool based on the excitation of characteristic

2003-01-01

354

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

355

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

357

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds  

Energy Technology Data Exchange (ETDEWEB)

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds were studied by electron and proton bombardments. L{sub {gamma}1} X-rays which involve transition of 4d electrons of the valence shell were found to be sensitive to the chemical environment. The L{sub {gamma}1}/L{sub {beta}1} X-ray intensity ratio increased with an increase of the 4d electron occupation of niobium or molybdenum in niobium or molybdenum compounds, showing that the chemical effects can be ascribed to the 4d electron behavior of the metallic atom in its compounds. (orig.).

1990-12-20

358

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds  

International Nuclear Information System (INIS)

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds were studied by electron and proton bombardments. L_#gamma#_1 X-rays which involve transition of 4d electrons of the valence shell were found to be sensitive to the chemical environment. The L_#gamma#_1/L_#beta#_1 X-ray intensity ratio increased with an increase of the 4d electron occupation of niobium or molybdenum in niobium or molybdenum compounds, showing that the chemical effects can be ascribed to the 4d electron behavior of the metallic atom in its compounds. (orig.).

1990-12-01

359

Structures and luminescent properties of new uranyl-based hybrid materials  

International Nuclear Information System (INIS)

Six uranyl coordination compounds, UO_2(OH)(PYCA) (1), UO_2(PYCA)_2(H_2O).2H_2O (2), UO_2(PIC)_2 (3), UO_2(H_2O)_2(NIC)_2 (4), UO_2(OH)(HINIC)(INIC) (5), and UO_2(PYTAC)_2(H_2O)_2 (6) were grown as single crystals via hydrothermal synthesis (PYCA - pyrazine-2-carboxylate, PIC - picolinate, NIC - nicotinate, INIC - iso-nicotinate, and PYTAC - 2-(pyridin-4-yl)thiazole-5-carboxylate) to study their optical properties. All six compounds have been identified via single crystal X-ray diffraction and fully characterized via powder X-ray diffraction, infrared spectroscopy, UV-Vis spectroscopy, and fluorescence spectroscopy. Three of the complexes, 1, 3, and 6, represent new structures, and their synthesis and structural characterization is detailed within. The structures of 2, 4, and 5 have previously been reported in the literature. Coordination polymer 1 crystallizes in the orthorhombic space group Pca21 (a = 13.5476(5) ...

2011-06-01

360

Luminescence of Strontianite (SrCO{sub 3}) from Strontian (Scotland, UK)  

Energy Technology Data Exchange (ETDEWEB)

An historic Strontianite-type specimen from Strontian, Scotland, UK, was characterized to broaden our knowledge on luminescence properties of common carbonates. These fibrous aggregates are Strontianite (Sr{sub x}Ca{sub 1-x}CO{sub 3}) with circa 6% of CaO, interfacial water, hydrosilicate anions and substitutional divalent cations, e.g., Ca{sup 2+}, Mn{sup 2+}, Fe{sup 2+} in structural Sr{sup 2+} positions. The specimen was analyzed by X-ray Fluorescence Spectrometry (XRF), Environmental Scanning Electron Microscopy coupled with an Energy Dispersive X-ray Spectroscopy (ESEM-EDS) probe, Spatially-resolved Cathodoluminescence under the Scanning Electron Microscope (SEM-CL), Differential-Thermal Analyses (DTA), Thermogravimetry (TG), Thermoluminescence (TL), Radioluminescence (RL) and High Resolution Spectra Thermoluminescence (3DTL), to gain an overview of the spectral emissions, the defect linkages were modified by heating ...

2009-04-15

361

Detection device for high explosives  

Energy Technology Data Exchange (ETDEWEB)

A portable fiber optic detector that senses the presence of specific target chemicals by electrostatically attracting the target chemical to an aromatic compound coating on an optical fiber. Attaching the target chemical to the coated fiber reduces the fluorescence so that a photon sensing detector records the reduced light level and activates an appropriate alarm or indicator.

1992-01-01

362

X-ray findings in patients with miliary appearance of metallic mercury after suicide attempt  

Energy Technology Data Exchange (ETDEWEB)

This case report evaluates X-ray findings in patients with miliary accumulation of mercury observed after parenteral application of metallic mercury in a suizide attempt. There are certain discrepancies between clinical symptoms and the X-ray findings. A clear demonstration of mercury in coronary blood vessels is possible by fluoroscopy.

1985-03-01

363

The evolution of x-ray binaries  

International Nuclear Information System (INIS)

These proceedings represent papers presented at the Astrophysics Conference in Maryland, USA. The topic of the Conference was the evolution of x-ray binaries and the papers encompass a wide range of subjects on x-ray astronomy. There were one hundred eighteen papers presented at the Conference and out of these three have been abstracted for the Energy Science and Technology database.

1993-10-11

364

Quantitative phase imaging using hard x-rays  

International Nuclear Information System (INIS)

The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.

2009-02-01

365

Pd-Na/F double exploding foil photoionization experiment  

Science.gov (United States)

The achievement of inner-shell photoionization of Zn-like Pd by means of two exploding foils is described. This resulted in the soft X-ray transition 3d94s2-3d104p at 46 A. It is shown that the photoionization of inner shell electrons in highly stripped ions can lead to X-ray transitions which may be candidates for X-ray lasers under 50 A.

1990-03-01

366

Multi-mirror system, 2. Application of inverse Compton Scattering for lithography X-ray sources  

Energy Technology Data Exchange (ETDEWEB)

A brilliant X ray source is proposed for lithography instruments with use of a multi-mirror system. The inverse Compton scattering between the stored electron beam in the storage ring and the stored photon beam in the multi-mirror system, is applied for the X-ray generation. (author)

2000-07-01

367

Measurement of the K?/K? ratio for muon alpha sticking X-rays in muon catalyzed d-t fusion at the RIKEN-RAL Muon Facility  

International Nuclear Information System (INIS)

At the RIKEN-RAL Muon Facility, ?- to ? sticking K? X-rays were observed for the first time taking advantage of the pulsed beam structure. The precision of the present measurements was insufficient to distinguish between theoretical models, however the observed K?/K? X-ray intensity ratio tends to be smaller than most of these theoretical predictions.

1999-06-01

368

Genetic and somatic risks in X-ray diagnosis  

International Nuclear Information System (INIS)

Based on a literature study an actual summary of the risk-utility problems in X-ray diagnosis is outlined due to the Recommendations of the International Commission for Radiation Protection (ICRP publication 26/1977). Papers demonstrating quantitative assessment of the somatic and genetical risk in X-ray examination are preferably cited and evaluated. It is concluded that the somatic and genetical risk is low in diagnostic ratiology. However, it must not be neglected and has always to be compared to the utility of an examination as well as to other risks of the examination. (author).

1982-01-01

369

From tomography to voludensitometry: radiation detectors for industrial control and medical instrumentation; De la tomographie a la voludensitometrie: les capteurs pour le controle industriel et l`instrumentation medicale  

Energy Technology Data Exchange (ETDEWEB)

In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).

1993-12-01

370

Temperature evolution of the internal magnetic hyperfine field of Metglas: amorphous and crystallized phases  

International Nuclear Information System (INIS)

We present differential scanning calorimetry (DSC), X-ray diffractometry, in situ Moessbauer spectroscopy (MS), and transmission electron microscopy (TEM) studies in Metglas ribbons subjected to different heat treatments. The temperature evolution of the hyperfine field H_h_f(T) and the Curie temperature (T_c) of the amorphous phase are determined. The magnetic field originally present in the amorphous phase has a 'normal' behavior, in the sense that it can be described by the Weiss molecular field theory. The total angular momentum of the iron atoms turns out to be 5/2 and this implies Fe"3"+ in which the electronic spins are uncoupled. When the samples are maintained near T_c (#approx#673 K), three new magnetic phases are detected in the Moessbauer spectra, indicating an onset of a crystallization process well below the first crystallization temperature (T_X_1), as determined by DSC (#approx#820 K). The magnetic behavior of these phases is ...

2000-11-01

371

A comparison of x-ray detectors for mouse CT imaging  

International Nuclear Information System (INIS)

There is significant interest in using computed tomography (CT) for in vivo imaging applications in mouse models of disease. Most commercially available mouse x-ray CT scanners utilize a charge-coupled device (CCD) detector coupled via fibre optic taper to a phosphor screen. However, there has been little research to determine if this is the optimum detector for the specific task of in vivo mouse imaging. To investigate this issue, we have evaluated four detectors, including an amorphous selenium (a-Se) detector, an amorphous silicon (a-Si) detector with a gadolinium oxysulphide (GOS) screen, a CCD with a 3:1 fibre taper and a GOS screen, and a CCD with a 2:1 fibre taper and both GOS and thallium-doped caesium iodide (CsI:Tl) screens. The detectors were evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), detective quantum efficiency (DQE), stability over multiple exposures, and noise in reconstructed CT ...

2004-12-07

372

Miniature x-ray source  

Energy Technology Data Exchange (ETDEWEB)

A miniature x-ray source utilizing a hot filament cathode. The source has a millimeter scale size and is capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature source consists of a compact vacuum tube assembly containing the hot filament cathode, an anode, a high voltage feedthru for delivering high voltage to the cathode, a getter for maintaining high vacuum, a connector for initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is fabricated from highly x-ray transparent materials, such as sapphire, diamond, or boron nitride.

2000-01-01

373

Influence of the X-ray radiation on the lifetime of carriers in the p-n junctions of Si and Ge  

International Nuclear Information System (INIS)

Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of lifetime of the charge carriers with the increase of X-ray radiation dose.

374

Gauging film thickness: A comparison of an x-ray diffraction technique with Rutherford backscattering spectrometry  

Energy Technology Data Exchange (ETDEWEB)

An x-ray diffraction technique for determining thin-film thickness is presented which should prove to be a valuable alternative to the array of spectroscopies (Rutherford backscattering spectrometry, Auger electron spectroscopy, etc.) currently favored for these measurements. Some of the virtues of this x-ray diffraction approach are its nondestructive nature, fast data acquisition rate (enabling in situ observations), thickness resolution better than 5 nm, and conventional equipment requirements. Results are shown for Pd/sub 2/Si thin films grown during isothermal annealing of Pd coatings (100 nm) on Si at 200 /sup 0/C for various amounts of time. A comparison of these x-ray measurements with Rutherford backscattering spectrometry data taken from the same specimens is used to demonstrate the validity of the x-ray technique.

1985-01-15

375

Fully Coherent X-ray Pulses from a Regenerative Amplifier Free Electron Laser  

Energy Technology Data Exchange (ETDEWEB)

We propose and analyze a novel regenerative amplifier free electron laser (FEL) to produce fully coherent x-ray pulses. The method makes use of narrow-bandwidth Bragg crystals to form an x-ray feedback loop around a relatively short undulator. Self-amplified spontaneous emission (SASE) from the leading electron bunch in a bunch train is spectrally filtered by the Bragg reflectors and is brought back to the beginning of the undulator to interact repeatedly with subsequent bunches in the bunch train. The FEL interaction with these short bunches not only amplifies the radiation intensity but also broadens its spectrum, allowing for effective transmission of the x-rays outside the crystal bandwidth. The spectral brightness of these x-ray pulses is about two to three orders of magnitude higher than that from a single-pass SASE FEL.

2006-02-17

376

Monitoring of DNA and cytogenetic damage in lymphocytes from persons with skin cancer diseases  

International Nuclear Information System (INIS)

There is a lot of interest in the studies that would help to understand whether there is a casual association between cancer and various types of molecular or cytogenetic damage detected in human cells. One major oncogenesis process is activation of proto-oncogenes by point mutations or chromosomal translocation. There are substantial evidence that indicates that the loss of heterozygosity of certain chromosomes is involved in human cancerogenesis. Our study aimed to elicit the possible association between cancer and DNA and cytogenetic abnormalities induced in lymphocytes of people bearing various categories of skin cancer cells. Fresh blood was collected by venipuncture from 25 individuals (including nine prior to cancer treatment). All patients were nonsmoking males, however 42.3 % of them were former smokers. Blood samples were divided into two parts and in the first part of samples cytogenetic studies were performed immediately, while from the second part ...

2004-11-01

377

Synthesis of reversible fluorescent organogel containing 2-(2prime-hydroxyphenyl)benzoxazole: fluorescence enhancement upon gelation and detecting property for nerve gas simulant  

British Library Electronic Table of Contents (United Kingdom)

A new low molecular mass organogelator 1 containing 2-(2prime-hydroxyphenyl)benzoxazole (HPB) group with long alkyl chain was synthesized by the reaction with 5-amino-2-(2prime-hydroxy-4prime-methylphenyl)benzoxazole and dodecyl isocyanate in THF at room temperature. The reversible gelation ability of 1 was investigated using a heating-cooling method in various organic solvents. The stable organogel was formed from carbon tetrachloride or from cyclohexane at the concentration as low as 0.9%. The self-assembled supramolecular gel structure formed by non-covalent bonding was confirmed with field emission-scanning electron microscope (FE-SEM) exhibiting fibril- or ribbon-shaped structure depending on the solvent used. Regarding the aggregation-induced emission enhancement (AIEE) phenomenon, t...

2010-01-01

378

Sequential injection system for phospholipase A2 activity evaluation: Studies on liposomes using an environment-sensitive fluorescent probe  

British Library Electronic Table of Contents (United Kingdom)

This work reports the development of an automatic methodology based on the use of 1-anilinonaphthalene-8-sulfonate (ANS) as an interfacial fluorescent probe for detecting the hydrophobic environment shift around the probe, caused by the hydrolytic action of PLA2 on the liposomes. The implementation of this reaction in a sequential injection analysis (SIA) system along with the use of the mixing chambers permitted the evaluation of PLA2 activity and assessment of the inhibitory effect of the non-steroidal anti-inflammatory drugs (NSAIDs) on PLA2 activity. Several studies were performed with the aim of establishing the appropriate flow system configuration: the liposome substrate; PLA2 and ANS optimum concentrations and incubation times before and after the enzyme addition. Based on these st...

2009-01-01

379

Amyloid oligomers: spectroscopic characterization of amyloidogenic protein states  

British Library Electronic Table of Contents (United Kingdom)

It is assumed that protein fibrils manifested in amyloidosis result from an aggregation reaction involving small misfolded protein sequences being in an `oligomeric' or `prefibrillar' state. This review covers recent optical spectroscopic studies of amyloid protein misfolding, oligomerization and amyloid fibril growth. Although amyloid fibrils have been studied using established protein-characterization techniques throughout the years, their oligomeric precursor states require sensitive detection in real-time. Here, fluorescent staining is commonly performed using thioflavin T and other small fluorescent molecules such as 4-(dicyanovinyl)- julolidine and 1-amino-8-naphtalene sulphonate that have high affinity to hydrophobic patches. Thus, populated oligomeric intermediates and related `pre...

2010-01-01

380

X-ray production with sub-picosecond laser pulses  

Energy Technology Data Exchange (ETDEWEB)

The interaction of intense, sub-picosecond laser pulses with solid targets produces intense picosecond x-ray pulses. With focused laser pulses of several 10 {sup 18} W/cm{sup 2}, He-like and H-like line radiation from targets such as aluminum and silicon has been produced. The energy conversion efficiency from the laser pulse energy to the 1--2 keV line x-rays is nearly one percent. The duration of the line x-ray radiation is of the order of ten picoseconds, although this may be an upper estimate because of the temporal resolution of the x-ray streak camera. The spatial extent of the x-ray source region is only slightly larger than the laser focal spot, or about 10 {mu}m in diameter. With these characteristics, such x-ray sources emit an intensity of nearly 10{sup 14} W/cm{sup 2}. Experiments and modeling which led to the above conclusions will be discussed.

1993-12-31

381

X-ray and UV-light irradiation effects on oxide superconducting thin films  

International Nuclear Information System (INIS)

Oxide superconducting thin films were irradiated with X-rays and ultra-violet (UV) light, and induced radiation effects on electrical and chemical properties were examined by transport measurement, X-ray diffraction analysis (XRD), diamagnetization measurement and X-ray photoemission spectroscopy (XPS). After irradiation for ErBa_2Cu_3O_x films with X-rays emitted from a Rh tube for 100 hours, superconductivity was remarkably damaged, destroying the zero-resistance state. The UV-light irradiation for Bi_2Sr_2CaCu_2O_x films was performed in He gas of about 500 Pa with a low pressure mercury lamp. The superconductivity was gradually degraded with the UV irradiation time up to 70 minutes. In both cases, adequate oxygen-annealing treatments restored superconductivity. The X-ray photoemission spectra showed that the mean Cu valence of the films was decreased approximately from +2 to +1 ...

382

Portable fluid X-ray diagnostic system  

Energy Technology Data Exchange (ETDEWEB)

A portable X-ray image system is described comprising: (a) a base assembly including panels and hinges joining the panels together along edges, and compression stops for biasing the hinges to compensate for the weight of payload when mounted on the base assembly, the compression stops being located for interaction with the hinges for biasing the panels to exhibit upward bowing when laid upon a flat surface prior to loading, and to provide resiliency for facilitating the base assembly assuming a substantially flat configuration when a predetermined payload is placed upon the base assembly; (b) an X-ray member; (c) apparatus for detachably mounting a table member to the base assembly to hold the table member at a location above the base; (d) an X-ray source; (e) means for sensing X-rays to form an image; (f) means for mounting the X-ray source and the X-ray ...

1989-02-14

383

Hard X-ray identification of Eta Carinae and steadiness close to periastron  

CERN Document Server

Context: The colliding-wind binary Eta Car exhibits soft X-ray thermal emission that varies strongly around periastron, and non-thermal emission seen in hard X-rays and gamma-rays. Aims: To definitively identify Eta Car as the source of the hard X-ray emission, to examine how changes in the 2-10 keV band influence changes in the hard X-ray band, and to understand more clearly the mechanisms producing the non-thermal emission using new INTEGRAL observations obtained close to periastron. Methods: A Chandra observation encompassing the ISGRI error circle was analysed, and all other soft X-ray sources (including the outer shell of Eta Car itself) were discarded as likely counter-parts. New hard X-ray images of Eta Car were studied close to periastron, and compared to previous observations far from periastron. Results: The INTEGRAL component, when represented by a ...

2010-01-01

384

Energetic electrons in impulsive and extended solar flares as deduced from flux correlations between hard X-rays and microwaves  

Energy Technology Data Exchange (ETDEWEB)

The peak flux relationship between hard X-rays and microwaves from solar flares is studied using about 400 events simultaneously recorded with the hard X-ray burst spectrometer on the SMM satellite and the Nobeyama 17 GHz radiometer. The data indicate that the hard X-ray and microwave peak fluxes correlate best for X-ray energies of less than about 80 keV for impulsive flares and greater than about 360 keV for extended flares. By postulating that electrons responsible for microwave emission at 17 GHz are those emitting hard X-rays at these photon energies, it is concluded that: (1) in impulsive flares, microwaves at about 20 GHz are emitted mainly by electrons of less than about 200 keV from a layer through which the electrons stream down into the thick-target hard X-ray source; and (2) in extended flares, microwaves are emitted mainly by MeV electrons trapped ...

1988-01-01

385

Application of imaging plate technology for NDT; Imaging plate gijutsu to sono oyo  

Energy Technology Data Exchange (ETDEWEB)

This paper describes Fuji computed radiography (FCR) of Fuji Film for NDT (non-destructive testing). Imaging plate (IP) is a two-dimensional detector of X-ray, and shows higher photographic sensitivity than X-ray film. The output emission of IP provides a good linear relationship to X-ray intensity in a wide intensity range. When this emission can be digitized, the X-ray intensity can be also digitized. IP is applied to NDT as an inspection using X-ray. FCR provides higher photographic sensitivity than the conventional X-ray film method, which results in one-fifth to one-twentieth of irradiation time. Images with stable density can be obtained independent of the intensity. Since IP has a wide dynamic range, the variation of X-ray intensity of 1:500 can be expressed in a single image by single shot. High density record including 1000 images ...

1998-10-01

386

Diagnostic and Prognostic Utility of t(14;18) in Follicular Lymphoma  

British Library Electronic Table of Contents (United Kingdom)

Abstract Background: Follicular lymphoma (FL) is one of the most common non-Hodgkin's lymphomas of B cells, being closely associated with a t(14;18) translocation. Detection of t(14;18), which is present in 70-95% of FL, might aid in FL diagnosis. Objective: To compare the efficacy of routine polymerase chain reaction (PCR) and fluorescence in situ hybridization (FISH) techniques in detecting t(14;18) in paraffin-embedded tissue samples of FL patients at different stages. Combined with other immunophenotypic biological determinants, detection of t(14;18) might help to determine patients at increased risk according to the FL International Prognostic Index (FLIPI) and therefore facilitate appropriate treatment. Design and Methods: This study was mainly based on a retrospective examination of...

2007-01-01

387

Fluorescence quantum yields and cascade-free lifetimes of state selected CO_2"+, COS"+, CS_2"+ and N_2O"+ determined by photoelectron-photon coincidence spectroccopy  

International Nuclear Information System (INIS)

The details and principles of an apparatus built for measurements of fluorescence quantum yields and cascade-free lifetimes of open-shell cations are reported. These rely on the detection of coincidences between energy selected photo-electrons and undispersed photons. The results of such measurements for CO"+_2,COS"+,CS"+_2 and N_2O"+ in selected vibrational levels of their excited states are presented. Non-unity fluorescence quantum yields are found for some vibronic levels of CO"+_2(B), COS"+(A), N_2O"+(A) and a non-exponential decay is observed for CS"+_2(B). The data yield the following values for the radiative lifetimes: CO"+_2(A) 124 +- 6 ns,CO"+_2(B) 140 +- 7 ns, COS"+(A) 550 +- 50 ns and N_2O"+(A) 240 +- 12 ns. (orig.).

1980-10-01

388

Fluorescence based molecular in vivo imaging; Fluoreszenzgestuetzte molekulare Bildgebung in vivo  

Energy Technology Data Exchange (ETDEWEB)

Molecular imaging represents a modern research area that allows the in vivo study of molecular biological process kinetics using appropriate probes and visualization methods. This methodology may be defined- apart from the contrast media injection - as non-abrasive. In order to reach an in vivo molecular process imaging as accurate as possible the effects of the used probes on the biological should not be too large. The contrast media as important part of the molecular imaging can significantly contribute to the understanding of molecular processes and to the development of tailored diagnostics and therapy. Since more than 15 years PTB is developing optic imaging systems that may be used for fluorescence based visualization of tissue phantoms, small animal models and the localization of tumors and their predecessors, and for the early recognition of inflammatory processes in clinical trials. Cellular changes occur during many diseases, thus the molecular imaging ...

2008-12-15

389

The Structural and Optical Properties of GaAs1-xPx /GaAs  

International Nuclear Information System (INIS)

GaAs1-xPx p-n junction structures were grown on the epi-ready n-type GaAs(100) substrate by solid source MBE system for different phosphor compositions. To obtain the lattice-match sample structure was applied graded growth procedure. The structural and optical properties of the sample structures with different P concentration were investigated by using X-ray diffraction (XRD), spectroscopic ellipsometry (SE). In addition, The range of lattice parameters in the graded epilayer and phosphorous composition were determined from the HRXRD rocking curve simulation. We analyse dielectric function spectra of disordered GaAs1-xPx junction structures measured using spectroscopic ellipsometry at room temperature in the 0.6-4.7 eV photon energy region. The critical energy points such as band gap energy and spin-orbit-split energy of these structures were determined using SE data. It is detected that E0, E1 ,E2 energies of the GaAs1-xPx p-n junction ...

2008-08-25

390

The H-test probability distribution revisited: Improved sensitivity  

CERN Document Server

Aims: To provide a significantly improved probability distribution for the H-test for periodicity in X-ray and $\\gamma$-ray arrival times, which is already extensively used by the $\\gamma$-ray pulsar community. Also, to obtain an analytical probability distribution for stacked test statistics in the case of a search for pulsed emission from an ensemble of pulsars where the significance per pulsar is relatively low, making individual detections insignificant on their own. This information is timely given the recent rapid discovery of new pulsars with the Fermi-LAT t $\\gamma$-ray telescope. Methods: Approximately $10^{14}$ realisations of the H-statistic ($H$) for random (white) noise is calculated from a random number generator for which the repitition cycle is $\\gg 10^{14}$. From these numbers the probability distribution $P(>H)$ is calculated. Results: The distribution of $H$ is is found to be exponential with parameter $\\lambda=0.4$ ...

2010-01-01

391

The Distribution and Condition of the Warm Molecular Gas in Abell 2597 and Sersic 159-03  

CERN Document Server

We have used the SINFONI integral field spectrograph to map the near-infrared K-band emission lines of molecular and ionised hydrogen in the central regions of two cool core galaxy clusters, Abell 2597 and Sersic 159-03. Gas is detected out to 20 kpc from the nuclei of the brightest cluster galaxies and found to be distributed in clumps and filaments around it. The ionised and molecular gas phases trace each other closely in extent and dynamical state. Both gas phases show signs of interaction with the active nucleus. Within the nuclear regions the kinetic luminosity of this gas is found to be somewhat smaller than the current radio luminosity. Outside the nuclear region the gas has a low velocity dispersion and shows smooth velocity gradients. There is no strong correlation between the intensity of the molecular and ionised gas emission and either the radio or X-ray emission. The molecular gas in Abell 2597 and Sersic 159-03 is well described ...

2010-01-01

392

Role of Stearic Acid in the Strain-Induced Crystallization of Crosslinked Natural Rubber and Synthetic Cis-1,4-Polyisoprene  

Energy Technology Data Exchange (ETDEWEB)

Strain-induced crystallization of crosslinked natural rubber (NR) and its synthetic analogue, cis-1,4-polyisoprene (IR), both mixed with various amounts of stearic acid (SA), were investigated by time-resolved X-ray diffraction using a powerful synchrotron radiation source and simultaneous mechanical (tensile) measurement. No acceleration or retardation was observed on NR in spite of the increase of SA amount. Even the SA-free IR crystallized upon stretching, and the overall crystallization behavior of IR shifted to the larger strain ratio with increasing SA content. No difference due to the SA was detected in the deformation of crystal lattice by stress for both NR and IR. These results suggested that the extended network chains are effective for the initiation of crystallization upon stretching, while the role of SA is trivial. These behaviors are much different from their crystallization at low temperature by standing, where SA acts as a ...

2007-01-01

393

Probing the Large-Scale Structure Around the Most Distant Galaxy Clusters from the Massive Cluster Survey  

CERN Document Server

We present maps of the cosmic large-scale structure around the twelve most distant galaxy clusters from the Massive Cluster Survey (MACS) as traced by the projected surface density of galaxies on the cluster red sequence. Taken with the Suprime-Cam wide-field camera on the Subaru telescope, the images used in this study cover a 27x27 arcmin^2 area around each cluster, corresponding to 10 x 10 Mpc^2 at the median redshift of z = 0.55 of our sample. We directly detect satellite clusters and filaments extending over the full size of our imaging data in the majority of the clusters studied, supporting the picture of mass accretion via infall along filaments suggested by numerical simulations of the growth of clusters and the evolution of large-scale structure. A comparison of the galaxy distribution near the cluster cores with the X-ray surface brightness as observed with Chandra reveals, in several cases, significant offsets between the gas and ...

2008-01-01

394

Preparation, characterization and electrical properties of SnO{sub 2} based liquid petroleum gas sensor  

Energy Technology Data Exchange (ETDEWEB)

The present investigation deals with the fabrication of liquid petroleum gas (LPG) sensor based on semiconducting oxide SnO{sub 2}. The gas sensor elements have been prepared by conventional solid state route. Addition of noble metal sensitizer, palladium and grain growth inhibitor, aluminum silicate to the base material SnO{sub 2}, not only improved the sensitivity towards LPG but also the selectivity in the presence of CO and CH{sub 4} gases. Out of various sensor compositions, SnO{sub 2}:Al{sub 2}Si{sub 2}O{sub 7} (35 wt.%):Pd (1.5 wt.%) sintered at 800 C for 5 h has shown high sensitivity (0.97) towards LPG at an operating temperature of 350 C. Different characterization techniques have been employed, such as differential thermal analysis (DTA), surface area analyzer, X-ray diffraction (XRD), to study the formation of SnO{sub 2}, surface area and crystallite size, respectively. The results suggested the possibility of utilizing the sensor element for the ...

1999-03-25

395

Precise characterisation of nanochannels in track etched membranes by SAXS and SANS  

Energy Technology Data Exchange (ETDEWEB)

Poster session: Abstract is full text. Track membranes are thin polymer foils irradiated by heavy ions. The defects created by the heavy ions are located along the ions trajectory, the track. It is possible to open channels by etching with a chemical agent. These channels are very uniform. Small Angle Scattering (of X rays and neutrons) give global information about the characteristics of the channel shape. As the nanochannels are strictly parallel, an excellent sample orientation is required to obtain interpretable spectra. Then shoulders due to the oscillations of the Bessel function (radial part of the channel shape Fourier transform) are easily seen in the scattered intensity in the PXY data treatment software of SAS spectra allow to determine the channel diameter with its dispersion law, to demonstrate the existence of a wall thickness with a linearly varying density, and to assess the roughness. PXY can also detect ...

2003-05-01

396

Photoluminescence of europium doped LiInO2 powder  

British Library Electronic Table of Contents (United Kingdom)

Abstract Lithium-indium oxide is one of the candidate materials as solid-state scintillators for solar neutrinos due to an inverse --decay of 115In to 115Sn. On the other hand, when doped with rare-earth ions such as Eu3+ or Sm3+, it becomes a promising phosphor material. In this report we present a simple solid-state procedure for preparation of LiInO2:Eu3+ powders. X-ray diffraction confirmed prod-uct in tetragonal structural form (space group: I41/amd) and no impurity phases were detected. Then, high resolution photoluminescence emission measurements were performed at room and low temperatures to find 5D0 - 7FJ. Emission kinetics from 5D0 level exhibited pure single exponential behavior with lifetime of about 1.5 ms. Maximum energy splitting of 7F1 manifold is recorded as a function of ...

2011-01-01

397

PIXE-PIGE analysis of some Indian medicinal plants  

Energy Technology Data Exchange (ETDEWEB)

The quantitative estimation of various trace element concentrations in medicinal plants is necessary for determining their effectiveness in treating various diseases and for understanding their pharmacological action. Elemental concentrations of some selected medicinal plants of north east India was measured by proton induced X-ray emission (PIXE) and proton induced {gamma}-ray emission (PIGE) techniques. PIXE measurements were carried out using 2.4 MeV collimated protons from the 3 MV tandetron accelerator of NCCCM, Hyderabad (India) while the PIGE measurements were carried out using 3 MeV protons from the same accelerator in the same laboratory. Accuracy and precision of the techniques were assured by analyzing certified reference materials in the same experimental conditions. Various elements of biological importance in man's metabolism were found to be present in varying concentrations in the studied medicinal plants and no toxic heavy metals were ...

2010-06-15

398

National and International Security Applications of Cryogenic Detectors - Mostly Nuclear Safeguards  

International Nuclear Information System (INIS)

As with science, so with security--in both arenas, the extraordinary sensitivity of cryogenic sensors enables high-confidence detection and high-precision measurement even of the faintest signals. Science applications are more mature, but several national and international security applications have been identified where cryogenic detectors have high potential payoff. International safeguards and nuclear forensics are areas needing new technology and methods to boost speed, sensitivity, precision and accuracy. Successfully applied, improved nuclear materials analysis will help constrain nuclear materials diversion pathways and contribute to treaty verification. Cryogenic microcalorimeter detectors for X-ray, gamma-ray, neutron, and alpha-particle spectrometry are under development with these aims in mind. In each case the unsurpassed energy resolution of microcalorimeters reveals previously invisible spectral features of nuclear materials. ...

2009-12-16

399

NGC 2770 - a supernova Ib factory?  

CERN Document Server

NGC 2770 has been the host of three supernovae of Type Ib during the last 10 years, SN 1999eh, SN 2007uy and SN 2008D. SN 2008D attracted special attention due to the serendipitous discovery of an associated X-ray transient. In this paper, we study the properties of NGC 2770 and specifically the three SN sites to investigate whether this galaxy is in any way peculiar to cause a high frequency of SNe Ib. We model the global SED of the galaxy from broadband data and derive a star-formation and SN rate comparable to the values of the Milky Way. We further study the galaxy using longslit spectroscopy covering the major axis and the three SN sites. From the spectroscopic study we find subsolar metallicities for the SN sites, a high extinction and a moderate star-formation rate. In a high resolution spectrum, we also detect diffuse interstellar bands in the line-of-sight towards SN 2008. A comparison of NGC 2770 to the global properties of a galaxy ...

2008-01-01

400

Midwave infrared type-II InAs/GaSb superlattice detectors with mixed interfaces  

Science.gov (United States)

We report the growth and fabrication of midwave infrared InAs/GaSb strain layer superlattice (SLS) detectors. Growth of alternate interfaces leads to a reduced strain between the GaSb buffer and SLS ({delta}a{sub parallel}/a=-5x10{sup -4}), enabling the growth of active regions up to 3 {mu}m (625 periods). The structural, optical, and electrical properties of the active region were characterized using x-ray crystallography and photoluminescence, respectively. p-i-n detectors were grown using 625 periods of 8 ML (monolayer) InAs/8 ML GaSb as the active region. The {lambda}{sub cutoff} for the detectors was 4.6 {mu}m with a conversion efficiency of 32% at V{sub b}=-0.2 V. Detectivity was obtained using noise power spectral density measurements under 300 K 2{pi} field of view illumination and was equal to 5.2x10{sup 10} and 3x10{sup 10} cm Hz{sup 1/2}/W (V{sub b}=-0.02 V, T=80 K) in the white noise and 1/f noise limit (at 50 Hz)

2006-07-01

401

Is there an enhancement of muons at sea level from transient events?  

CERN Document Server

In a recent study of a search for enhancements from the galactic center with muons at sea level using the TUPI muon telescope, we have found several ground level enhancements (GLEs) as very sharp peaks above the count rate background. This paper reports a consistent analysis of two GLEs observed in December 2003 and detected after an up-grade of the data acquisition system, which includes a noise filter and which allows us to verify that the GLEs are not mere background fluctuations. The main target of this study is a search for the origin of the GLEs. The results show that one of them has a strong correlation with a solar flare, while the other has an unknown origin, because there is neither a satellite report of a solar flare, nor prompt X-ray emission, and nor a excess of nuclei during the raster scan where the GLE was observed. Even so, two possibilities are analyzed: the solar flare hypothesis and the gamma ray burst (GRB) hypothesis. We ...

2004-01-01

402

Instrumentation and Controls Division progress report, September 1, 1980-July 1, 1982  

Energy Technology Data Exchange (ETDEWEB)

Activities are reported by the Reactor Systems Section, Research Instrument Section, and the Measurement and Controls Engineering Section. Reactor system activities include dynamic analysis, survillanc and diagnostic methods, design and evaluation, detectors, facilities support, process instrumentation development, and special assignments. Activities in the Research Instrument Section include the Navy-ORNL RADIAC development program, advanced ..gamma.. and x ray detector systems, neutron detection and subcriticality measurements, circuit development, position-sensitive detectors, stand-alone computers, environmental monitoring-detectors and systems, plant security, engineering support for fusion energy division, engineering support for accelerator physics, and communications: radio, closed-circuit tv, and computer. Activities in the Measurement and Controls Engineering Section include the AVLIS program; gas centrifuge ...

1982-12-01

403

Influence of temperature on corrosion behavior of PbCaSnCe alloy in 4.5 M H{sub 2}SO{sub 4} solution  

Energy Technology Data Exchange (ETDEWEB)

The temperature effect on corrosion behaviors of PbCaSnCe alloy in 4.5 M H{sub 2}SO{sub 4} solution was investigated by using potentiodynamic curve, electrochemical impedance spectra (EIS), Mott-Schottky plot and photocurrent response methods. It was found that PbCaSnCe alloy was in passive state in sulfuric acid solution, a passive film can be formed on alloy surface. The compositions of passive films formed at 0.9 V for 2 h under different temperatures were detected by X-ray photoelectron spectroscopy (XPS). The results showed that the film resistance and the transfer resistance decreased with the increment of the solution temperature. Mott-Schottky analysis and the photocurrent response revealed that the passive film exhibited n-type semi-conductive character, the donor density of the passive film decreased with increasing the solution temperature. Photocurrent response revealed that the photocurrent increased with increasing temperature. ...

2010-01-15

404

Hydrogen behavior in the iron surface layer modified by plasma nitriding and ion boronising  

Energy Technology Data Exchange (ETDEWEB)

The effects of the plasma nitriding with the formation of compound nitride and diffusion zones and of the boronising with the different ion doses on hydrogen distribution and hydrogen induced deterioration of a surface layer were examined in the case of Armco iron. Electrochemical studies of hydrogen permeation rate, hydrogen vacuum extraction measurements, optical and scanning microscopy, X-ray diffraction and elastic recoil detection analysis (ERDA) were used. Accumulation of entering hydrogen within the various constituent zones of the modified layer inhibits the hydrogen transport into the metal and thus, decreases the mean hydrogen content in the deeper zones and in the core. Hydrogen accumulation within the compact nitride zone causes the expansion of the nitride lattice, nitride phase transformation and deterioration. The ion boronising enhances the hydrogen effects in the plasma nitrided layers. Therefore, modification of the surface ...

2000-12-01

405

High variability in Vela X-1: giant flares and off states  

CERN Document Server

We investigate the spectral and temporal behavior of the high mass X-ray binary Vela X-1 during a phase of high activity, with special focus on the observed giant flares and off states. INTEGRAL observed Vela X-1 in a long almost uninterrupted observation for two weeks in 2003 Nov/Dec. The data were analyzed with OSA 7.0 and FTOOLS 6.2. We derive the pulse period, light curves, spectra, hardness ratios, and hardness intensity diagrams, and study the eclipse. In addition to an already high activity level, Vela X-1 exhibited several intense flares, the brightest ones reaching a maximum intensity of more than 5 Crab in the 20-40 keV band and several off states where the source was no longer detected by INTEGRAL. We determine the pulse period to be 283.5320+/-0.0002 s, which is stable throughout the entire observation. Analyzing the eclipses provided an improvement in the ephemeris. Spectral analysis of the flares indicates that there appear to be ...

2008-01-01

406

Evaluation of passive films by photo and impedance spectroscopy; Bunkoho oyobi inpidansu ho ni yoru himaku hyoka  

Energy Technology Data Exchange (ETDEWEB)

The passive films formed on iron metal, alloys or stainless steel are extremely thin oxides or hydroxides and possess the properties of high chemical stability in the environment. These films show characteristics interested both electrical as well as electrochemical point of view due to the thin thickness of the films. Auger Electron Spectroscopy, X-ray Photoelectron spectroscopy and so on which are the conventional electrochemical measurement methods or the surface analysis methods are used for the analysis and evaluation of these films, however, at present, the application of research technique focusing the superconductor characteristics of the films are tried. Although, the potential modulation reflection spectroscopy method has merits like possibility of in-situ measurement, high precision, possibility of stable analysis even for extremely thin film and so forth, it has also demerits like difficulty to response the potential modulation of hydroxides and also ...

1995-09-20

407

Elemental investigation of Syrian medicinal plants using PIXE analysis  

Energy Technology Data Exchange (ETDEWEB)

Particle induced X-ray emission (PIXE) technique has been employed to perform elemental analysis of K, Ca, Mn, Fe, Cu, Zn, Br and Sr for Syrian medicinal plants used traditionally to enhance the body immunity. Plant samples were prepared in a simple dried base. The results were verified by comparing with those obtained from both IAEA-359 and IAEA-V10 reference materials. Relative standard deviations are mostly within {+-}5-10% suggest good precision. A correlation between the elemental content in each medicinal plant with its traditional remedial usage has been proposed. Both K and Ca are found to be the major elements in the samples. Fe, Mn and Zn have been detected in good levels in most of these plants clarifying their possible contribution to keep the body immune system in good condition. The contribution of the elements in these plants to the dietary recommended intakes (DRI) has been evaluated. Advantages and limitations of PIXE ...

2010-09-15

408

Digital direct magnification mammography with storage phosphor screens. Standardized and image result dependent post-processing parameters  

International Nuclear Information System (INIS)

Present day mammography has not been able to make use of the advantages of digital luminescence radiography because of the limited spatial resolution. The recent development of electromagnetic focusing X-ray tube with effective focal spot sizes from 0.04 to 0.12 mm allows radiographic direct magnification with less geometric blur. It is now possible to combine direct magnification mammography with digital luminescence radiography. By combining high quality storage phosphor screens with an HQ-workstation a spatial resolution of 8 lp/mm is possible for 1.7-fold magnification. For 4-fold spot magnification views spatial resolution can be theoretically increased to approx. 20 lp/mm. One important advantage of digital radiography is the possibility of image-postprocessing. This article presents two sets of standard parameters and three sets of image dependent parameters for better imaging of specific lesions, such as microcalcifications. The introduction of the storage ...

409

Development of Micromegas-like gaseous detectors using a pixel readout chip as collecting anode  

International Nuclear Information System (INIS)

This thesis reports on the fabrication and test of a new gaseous detector with a very large number of readout channels. This detector is intended for measuring the tracks of charged particles with an unprecedented sensitivity to single electrons of almost 100 %. It combines a metal grid for signal amplification called the Micromegas with a pixel readout chip as signal collecting anode and is dubbed GridPix. GridPix is a potential candidate for a sub-detector at a future electron linear collider (ILC) foreseen to work in parallel with the LHC around 2020--2030. The tracking capability of GridPix is best exploited if the Micromegas is integrated on the pixel chip. This integrated grid is called InGrid and is precisely fabricated by wafer post-processing. The various steps of the fabrication process and the measurements of its gain, energy resolution and ion back-flow property are reported in this document. Studies of the response of the complete detector formed by an InGrid and a TimePix ...

410

Detection of Second-Layer Corrosion in Aging Aircraft Fuselage  

International Nuclear Information System (INIS)

A Digital X-ray imaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS method): A simple reconstruction model is also ...

2006-12-01

411

Dependence of anomalous phosphorus diffusion in silicon on depth position of defects created by ion implantation  

Energy Technology Data Exchange (ETDEWEB)

Transient enhanced diffusion of phosphorus in silicon has been investigated for implants below and above the threshold for a complete amorphization. Rapid thermal processes (electron beam) and conventional furnaces have been used for the annealing. In the case of implants below amorphization, a strong enhanced diffusion, proportional to the amount of damage produced, has been observed. The extent of the phenomenon is practically independent of the damage depth position. In contrast to this, the formation of extended defects at the original amorphous-crystalline interface makes the diffusivity strongly dependent on depth in the case of post-amorphized samples. No enhanced diffusion effect is observed if the dopant is confined in the amorphous layer, while a remarkable increase in the diffusivity is detected for the dopant located in the crystalline region beyond the amorphous-crystalline interface. Damage distribution after implantation and its evolution during ...

1989-03-01

412

Constraining the Dark Energy Equation of State using Alternative High-z Cosmic Tracers  

CERN Document Server

We propose to use alternative cosmic tracers to measure the dark energy equation of state and the matter content of the Universe [w(z) & Omega_m]. Our proposed method consists of two components: (a) tracing the Hubble relation using HII galaxies which can be detected up to very large redshifts, z~4, as an alternative to supernovae type Ia, and (b) measuring the clustering pattern of X-ray selected AGN at a median redshift of z~1. Each component of the method can in itself provide interesting constraints on the cosmological parameters, especially under our anticipation that we will reduce the corresponding random and systematic errors significantly. However, by joining their likelihood functions we will be able to put stringent cosmological constraints and break the known degeneracies between the dark energy equation of state (whether it is constant or variable) and the matter content of the universe and provide a powerful and alternative ...

2009-01-01

413

Computed radiography (FCR) with a dual side reading system. Comparison with conventional radiography for visualization of nodular lung cancers  

International Nuclear Information System (INIS)

To assess the diagnostic capability Fuji computed radiography (FCR) using a dual side reading system was compared to the conventional radiography using a film-screen system. Twenty-eight patients with lung cancer were examined with a new FCR system (FCR 5501D) and a conventional screen-film system concurrently. FCR utilizes a reading system that detects emissions from dual sides of imaging plate. Chest X-rays were obtained with same exposure factors in both systems. Image qualities of both systems were compared by two radiologists using a five-level score. There were no lesion that FCR images were inferior to film-screen images. The frequency of score +1 or +2 that FCR images were superior to film-screen images was 31% in large nodular shadows, 40% in accompanying shadows with a nodule, 67% of small nodular shadows, and 43% of the lymph node swelling in the hilum of the lung or mediastinum. In large nodular shadows which were the most frequent ...

2003-02-01

414

Computational AstroStatistics Fast and Efficient Tools for Analysing Huge Astronomical Data Sources  

CERN Document Server

I present here a review of past and present multi-disciplinary research of the Pittsburgh Computational AstroStatistics (PiCA) group. This group is dedicated to developing fast and efficient statistical algorithms for analysing huge astronomical data sources. I begin with a short review of multi-resolutional kd-trees which are the building blocks for many of our algorithms. For example, quick range queries and fast n-point correlation functions. I will present new results from the use of Mixture Models (Connolly et al. 2000) in density estimation of multi-color data from the Sloan Digital Sky Survey (SDSS). Specifically, the selection of quasars and the automated identification of X-ray sources. I will also present a brief overview of the False Discovery Rate (FDR) procedure (Miller et al. 2001a) and show how it has been used in the detection of ``Baryon Wiggles'' in the local galaxy power spectrum and source identification in radio data. ...

2001-01-01

415

An evaluation of low-dose single-slice helical CT in pulmonary CT scan  

International Nuclear Information System (INIS)

Objective: To investigate the feasibility of low-dose single-slice helical CT in pulmonary CT scan and evaluate the clinical application. Methods: Thirteen cases were selected out of 132 cases, in which low-dose (50mAs) single-slice helical CT scan of chest was performed. This set of cases included 7 cases of multiple metastatic nodules; 3 of solitary pulmonary, nodule; and 3 of pulmonary patchy lesions. Regular dose (170mAs) CT scan was also performed on all those patients. The regular dose and low dose CT scan were compared on sensitivity of detecting the lesions; the performance in demonstrating the details of the abnormalities; and the capability of revealing the segmental bronchi as well. Results: The same number and size of the pulmonary nodules were revealed with scan modalities loaded with different doses. No significant difference in demonstrating the details of the nodules and the segmental bronchi was found between both modalities (#chi#"2=0.123-3.39, ...

2006-04-01

416

Alternative High-z Cosmic Tracers and the Dark Energy Equation of State  

CERN Document Server

We propose to use alternative cosmic tracers to measure the dark energy equation of state and the matter content of the Universe [w(z) & \\Omega_m]. Our proposed method consists of two components: (a) tracing the Hubble relation using HII-like starburst galaxies, as an alternative to SNIa, which can be detected up to very large redshifts, z~4, and (b) measuring the clustering pattern of X-ray selected AGN at a median redshift of ~1. Each component of the method can in itself provide interesting constraints on the cosmological parameters, especially under our anticipation that we will reduce the corresponding random and systematic errors significantly. However, by joining their likelihood functions we will be able to put stringent cosmological constraints and break the known degeneracies between the dark energy equation of state (whether it is constant or variable) and the matter content of the universe and provide a powerful and alternative ...

2009-01-01

417

4U 1907+09: a HMXB running away from the Galactic plane  

CERN Document Server

We report the discovery of a bow shock around the high-mass X-ray binary (HMXB) 4U 1907+09 using the Spitzer Space Telescope 24 $\\mu$m data (after Vela X-1 the second example of bow shocks associated with HMXBs). The detection of the bow shock implies that 4U 1907+09 is moving through the space with a high (supersonic) peculiar velocity. To confirm the runaway nature of 4U 1907+09, we measured its proper motion, which for an adopted distance to the system of 4 kpc corresponds to a peculiar transverse velocity of $\\simeq 160 \\pm 115$ km/s, meaning that 4U 1907+09 is indeed a runaway system and supporting the general belief that most of HMXBs possess high space velocities. The direction of motion of 4U 1907+09 inferred from the proper motion measurement is consistent with the orientation of the symmetry axis of the bow shock, and shows that the HMXB is running away from the Galactic plane. We also present the Spitzer images of the bow shock ...

2011-01-01

418

Radiation 2006. In association with the Polymer Division, Royal Australian Chemical Institute. Incorporating the 21st AINSE Radiation Chemistry Conference and the 18th Radiation Biology Conference, conference handbook  

International Nuclear Information System (INIS)

Full text: The general population is daily exposed to chronic, low doses of ionizing radiation (IR) from both natural and artificial sources. The biological consequences of acute, high dose IR exposure can be readily determined; however, the nature and significance of low dose, low dose-rate IR effects are still the subject of debate. Confounding the issue, are the phenomena collectively referred to as the Radiation-induced Bystander Effect (RIBE). The RIBE describes a collection of in vitro observations that suggest the presence of a soluble, transmissible factor(s) released from irradiated cells that can induce a biological response in un-irradiated cells. The induction, nature and magnitude of the RIBE varies between cell culture systems, radiation sources and end-points measured. Efforts to confirm the presence of the RIBE in vivo have been confined to in vivo-like culture systems and limited work with tumour and bone-marrow transplantation models. Validation of the RIBE in vivo ...

2006-01-01

419

Inorganic profile of some Brazilian medicinal plants obtained from ethanolic extract and ''in natura'' samples  

Energy Technology Data Exchange (ETDEWEB)

The Anadenathera macrocarpa, Schinus molle, Hymenaea courbaril, Cariniana legalis, Solidago microglossa and Stryphnodendron barbatiman, were collected ''in natura'' samples (leaves, flowers, barks and seeds) from different commercial suppliers. The pharmaco-active compounds in ethanolic extracts had been made by the Mato Grosso Federal University (UFMT). The energy-dispersive x-ray fluorescence (ED-XRF) spectrometry was used for the elemental analysis in different parts of the plants and respective ethanolic extracts. The Ca, Cl, Cu, Fe, K, Mg, Mn, Na, Ni, P, Rb, S, Sr and Zn concentrations were determined by the fundamental parameters method. Some specimens showed a similar inorganic profile for ''in natura'' and ethanolic extract samples and some ones showed a distinct inorganic profile. For example, the Anadenathera macrocarpa showed a similar concentration in Mg, P, Cu, ...

2004-10-03

420

In vitro H2AX phosphorylation and micronuclei induction in human fibroblasts across the Bragg curve of a 577MeV/nucleon Fe incident beam  

Energy Technology Data Exchange (ETDEWEB)

The space environment consists of a varying field of radiation particles including high-energy ions, with spacecraft shielding material providing the only major protection to astronauts from harmful exposure. Unlike low-linear energy transfer (LET) {gamma} or X-rays, the presence of shielding does not always reduce the radiation risks for energetic charged particle exposure, since the dose delivered by the charged particle increases sharply as the particle approaches the end of its range, a position known as the Bragg peak. The Bragg curve does not necessarily represent the biological damage along the particle traversal, and the 'biological Bragg curve' is dependent on the energy and the type of the primary particle, and may vary for different biological endpoints. Here we used a unique irradiation geometry to measure the biological response across the Bragg curve in human fibroblasts exposed to 577MeV/nucleon incident Fe ions in vitro. ...

2006-10-15

421

Formation of silk fibroin nanoparticles in water-miscible organic solvent and their characterization  

Energy Technology Data Exchange (ETDEWEB)

When Silk fibre derived from Bombyx mori, a native biopolymer, was dissolved in highly concentrated neutral salts such as CaCl{sub 2}, the regenerated liquid silk, a gradually degraded peptide mixture of silk fibroin, could be obtained. The silk fibroin nanoparticles were prepared rapidly from the liquid silk by using water-miscible protonic and polar aprotonic organic solvents. The nanoparticles are insoluble but well dispersed and stable in aqueous solution and are globular particles with a range of 35-125 nm in diameter by means of TEM, SEM, AFM and laser sizer. Over one half of the {epsilon}-amino groups exist around the protein nanoparticles by using a trinitrobenzenesulfonic acid (TNBS) method. Raman spectra shows the tyrosine residues on the surface of the globules are more exposed than those on native silk fibers. The crystalline polymorph and conformation transition of the silk nanoparticles from random-coil and {alpha}-helix form (Silk I) into anti-parallel {beta}-sheet form ...

2007-10-15

422

Crystal structure of ABPO{sub 5} and optical study of Pr{sup 3+} embedded in these compounds  

Energy Technology Data Exchange (ETDEWEB)

The crystal structure of borophosphates ABPO{sub 5} (A = alkaline earth or Pb) was resolved on a polycrystalline sample using the Rietveld method. The x-ray diffraction patterns data show that ABPO{sub 5} crystallize in a centrosymmetric space group P3{sub 1}21 and their structure is related to the borogermanates REBGeO{sub 5} with a stillwellite-type structure. Pr{sup 3+} ion was used as a local structural probe to corroborate the structural resolution results. Absorption and fluorescence spectra of A{sub 1-x}Pr{sub x}BP{sub 1-x}Ge{sub x}O{sub 5} (A alkaline earth or Pb; x = 0.05) have been investigated at different temperatures. At 9 K the 3{sup H}{sub 4}{yields}{sup 3}P{sub 0} transition of trivalent praseodymium ion (4f{sup 2} configuration) is observed as a single line. This indicates a unique crystallographic site for the rare earth ion in these compounds replacing the divalent cation. Energy level schemes were deduced from the ...

2001-10-22

423

Crystal structure of ABPO_5 and optical study of Pr"3"+ embedded in these compounds  

International Nuclear Information System (INIS)

The crystal structure of borophosphates ABPO_5 (A = alkaline earth or Pb) was resolved on a polycrystalline sample using the Rietveld method. The x-ray diffraction patterns data show that ABPO_5 crystallize in a centrosymmetric space group P3_121 and their structure is related to the borogermanates REBGeO_5 with a stillwellite-type structure. Pr"3"+ ion was used as a local structural probe to corroborate the structural resolution results. Absorption and fluorescence spectra of A_1_-_xPr_xBP_1_-_xGe_xO_5 (A alkaline earth or Pb; x = 0.05) have been investigated at different temperatures. At 9 K the 3"H_4#->#"3P_0 transition of trivalent praseodymium ion (4f"2 configuration) is observed as a single line. This indicates a unique crystallographic site for the rare earth ion in these compounds replacing the divalent cation. Energy level schemes were deduced from the low-temperature spectroscopic measurements. Comparing the electronic level ...

2001-10-22

424

The influence of different SPECT reconstruction algorithms on cardiac ischemia with the use artificial neural networks  

International Nuclear Information System (INIS)

The aim of the study was the attempt to evaluate the influence of two different methods of cardiac perfusion SPECT reconstruction (FBP and ITW) on clinical efficacy in diagnosing the coronary artery disease as well as the cardiac ischemia detection in three areas of heart vascularized by main coronary arteries: LAD, LCX and RCA with the use of artificial neural networks (ANN). The study was performed retrospectively with the use of the diagnostic image records as well as clinical dataset of 43 patients. Myocardial perfusion stress/rest SPECT study and X-ray coronarography data were evaluated for each patient. The results of coronary angiography were considered the reference method. The cardiac SPECT data were reconstructed using the two different methods: filtered backprojection (FBP) and iterative Wallis method (ITW). The local perfusion deficits denominated in stress and rest study in three main vessel cardiac segments were the main input ...

425

Status of the WAND (Waste Assay for Nonradioactive Disposal) project as of July 1997  

Energy Technology Data Exchange (ETDEWEB)

The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform the data analysis. WAND system minimum detectable activities (MDAs) for point sources ...

1998-03-01

426

Determination of the Integral/SPI instrumental response and his application to the observation of gamma ray lines in the Vela region; Determination de la reponse instrumentale du spectrometre INTEGRAL/SPI et application a l'observation des raies gamma de la region des Voiles  

Energy Technology Data Exchange (ETDEWEB)

The INTEGRAL/SPI spectrometer was designed to observe the sky in the energy band of 20 keV to 8 MeV. The specificity of instrument SPI rests on the excellent spectral resolution (2.3 keV with 1 MeV) of its detecting plan, composed of 19 cooled germanium crystals; covering an effective area of 508 cm{sup 2}. The use of a coded mask, located at 1.7 m above the detection plan ensures to it a resolving power of 2.5 degrees. The aim of this thesis, begun before the INTEGRAL launch, is made up of two parts. The first part relates to the analysis of the spectrometer calibration data. The objective was to measure and check the performances of the telescope, in particular to validate simulations of the INTEGRAL/SPI instrument response. This objective was successfully achieved. This analysis also highlights the presence of a significant instrumental background noise. Whereas, the second part concentrates on the data analysis of the Vela region ...

2005-01-15

427

Use of x-ray imaging for evaluation of superconducting ceramics fabricated by PIT method  

Energy Technology Data Exchange (ETDEWEB)

High-spatial-resolution microfocus-based X-ray imaging technology, both real-time and film, has been used to study the thickness variation that occurs in the oxide core of silver-sheathed BSCCO ribbons produced by the powder-in-tube method. This thickness variation (also called ``sausaging``) occurs during incremental rolling and degrades the critical current densities of the ribbons. Using X-ray image data the authors determined the onset and severity of sausaging. Onset occurred at a ribbon thickness of 203 {micro}m, and the severity increased with subsequent rolling reductions. Scanning electron microscopy was used to confirm the X-ray image data. X-ray imaging provides several advantages over more traditional methods for characterizing the superconductors such as optical or scanning electron microscopy. The X-ray imaging provides nondestructive information about the entire width ...

1993-08-01

428

A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: a theoretical study on 10-MV X-ray dose calculations in thorax-like phantoms  

British Library Electronic Table of Contents (United Kingdom)

A convolution/superposition method is proposed for use with primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. It should be noted that the number of energy bins is usually about ten, and that the reconstructed X-ray spectra can reasonably be applied to media with a wide range of effective Z numbers, ranging from water to lead. The study was carried out for 10-MV X-ray doses in water and thorax-like phantoms with the use of open-jaw-collimated fields. The dose calculations were made separately for primary, scatter, and electron contamination dose components, for which we used two extended radiation sources: one was on the X-ray target and the other on the flattening filter. To calculate the in-air beam intensities at po...

2011-01-01

429

Functionalized luminescent oxide nanoparticles for sodium channel imaging at the single molecule level  

Science.gov (United States)

Lanthanide-ion doped oxide nanoparticles were functionalized for use as fluorescent biological labels. These nanoparticles are synthesized directly in water which facilitates their functionalization, and are very photostable without emission intermittency. Nanoparticles functionalized with guanidinium groups act as artificial toxins and specifically target sodium channels. They are individually detectable in cardiac myocytes, revealing a heterogeneous distribution of sodium channels. Functionalized oxide nanoparticles appear as a novel tool particularly well adapted to long-term single-molecule tracking.

2005-04-01

430

Flow cytogenetics methodology and applications  

Energy Technology Data Exchange (ETDEWEB)

Flow cytogenetics is a rapidly developing technology which complements rather than supplants the traditional methods of cytogenetic analysis. As an adjunctive approach to chromosome classification, flow systems measurements of isolated chromosomes give new information relative to the enrichment of A-T or G-C base sequences on specific chromosomes. As a result, chromosomal fluorescence polymorphisms both within and among individuals that are not always associated with banding polymorphisms can be detected. Finally, flow sorting provides bulk quantities of highly purified chromosomes for use in biochemical studies. Methodology is detailed. (PSB)

1982-10-17

431

Dimensionally dependent luminescence of boron difluoride ?-diketonates  

International Nuclear Information System (INIS)

The results of the study of dimensionally dependent fluorescence of boron difluoride ?-diketonates of general formula (R1COCHCOR2)BF2 are presented. The fact that for most of the compounds studied a noticeable hypsochrome shift of the luminescence band maximum is characteristic during transition from bulk crystals to microcrystals was detected. However, for boron difluoride dibenzoylmethanate having a unique supramolecular structure, a bathochromic shift of luminescence due to the crustal size reduction is observed. The dimensionally dependent luminescence properties of the complexes have been analyzed within the exciton mechanism

2008-06-01

432

Analysis of o-tyrosine as a method for the identification of irradiated chicken and the comparison with other methods (analysis of volatiles and ESR-spectroscopy)  

Energy Technology Data Exchange (ETDEWEB)

With the mentioned method to analyse O-tyrosine with HPLC/fluorescence-detection, the irradiation of chicken meat can be determined in a simple and fast way. The formation of o-tyrosine is proportional to the applied dose but because it is also depending on the applied dose rate and the temperature during the irradiation, it is not possible to control the irradiation dose. Since unirradiated chicken can contain little amounts of o-tyrosine and to confirm some results, a second method is needed. Together with one of the other mentioned methods (analysis of the volatiles or esr-spectroscopy) it is possible to recognize irradiated chicken with a high security. (author).

1990-01-01

433

Standard samples for X-ray radiometric analysis of substance composition  

International Nuclear Information System (INIS)

Some aspects of metrological provision of X-ray radiometric analyzers for mineral raw composition and gamma-gamma-logging equipment are considered. Standard samples (SS) based on the phenol-formaldehyde resin with the introduced quantities calculated of element compositions in the form of oxides and salts are described. Principles of metrological provision developed are used when carrying out state acceptance tests of X-ray radiometric analyzer RAL-M-102 ''Ehkran'' and gamma-gamma-logging equipmnt RSK-102. Economic benefit from introduction of an SS set is #approx# 60-100 thousand roubles per year.

434

Soft x-ray microradiography and lithograph using a laser produced plasma source. Final report  

Energy Technology Data Exchange (ETDEWEB)

Considering the hardware characteristics of the laser-induced plasma X-ray source and the limitations of the conventional cone-beam reconstruction algorithm, a general cone-beam reconstruction algorithm has been developed at our laboratory, in which the motion locus of the X-ray source is an arbitrary curve corresponding to at least a 2{pi} continuous horizontal angular displacement in the coordinate system of the specimen. The preliminary simulation shows that the general cone-beam reconstruction algorithm consistently results in visually satisfactory images.

1992-03-01

435

Soft x-ray microradiography and lithograph using a laser produced plasma source  

Energy Technology Data Exchange (ETDEWEB)

Considering the hardware characteristics of the laser-induced plasma X-ray source and the limitations of the conventional cone-beam reconstruction algorithm, a general cone-beam reconstruction algorithm has been developed at our laboratory, in which the motion locus of the X-ray source is an arbitrary curve corresponding to at least a 2{pi} continuous horizontal angular displacement in the coordinate system of the specimen. The preliminary simulation shows that the general cone-beam reconstruction algorithm consistently results in visually satisfactory images.

1992-01-01

436

Role of nuclear medicine bone scans in evaluating pain in athletic injuries  

Energy Technology Data Exchange (ETDEWEB)

The utilization of nuclear medicine bone scanning examinations early in the diagnostic process allows physicians to render prompt and correct treatment in urgent or difficult athletic cases. Bone scanning should be performed for athletic injuries whenever (1) x-rays are normal but bone or joint pain persists; (2) x-rays are positive but it cannot be determined if the findings are acute or chronic; (3) soft-tissue injuries present and x-rays are not useful; and (4) bone pain or joint impairment present without a history of trauma.89 references.

1987-10-01

437

Radiological protection. Textbook for radiographers and reference book for radiological safety officers  

International Nuclear Information System (INIS)

The textbook is primarily intended for radiologic staff and radiologic safety officers and gives information on the current regulatory provisions of the German X-ray Ordinance, applications of X-rays, quality assurance, organisational aspects of film processing and quality requirements of X-rays. An annex lists the guidelines of the Bundesaerztekammer (German National Chamber of Physicians) relating to quality assurance aspects, and further useful information on commercially available film-screen systems, the various associations of physicians in Germany, and requirements and performance of radiation surveys. (vhe).

438

Radiation-protection survey guide: fixed radiographic unit. Final report, June 1980-April 1985  

Energy Technology Data Exchange (ETDEWEB)

Prior to routine use, all newly installed x-ray machines must have a radiation-protection survey by a qualified expert. The survey is an evaluation of existing or potential radiation hazards associated with the use of diagnostic x-ray equipment under specific conditions. Such evaluation includes the measurement of exposure levels in the environment as well as environmental levels arising from operation of the equipment. The survey also includes an evaluation of the safety characteristics of the x-ray unit.

1985-05-01

439

Patient doses in the Netherlands. [X-ray diagnosis and radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

Contributions to the population dose due to medical applications of ionising radiation are presented. It appears that contributions due to radiotherapy and X ray diagnosis are of comparable magnitude. To account for the age dependency of the radiation risks, contributions in terms of somatically significant dose equivalent are calculated as 0.3 mSv per caput per annum for X ray diagnosis and as 0.2 mSv per caput per annum for radiotherapy, the latter referring to only doses to organs outside the target volume. (author).

1991-01-01

440

Measurement of the K{sub {beta}}/K{sub {alpha}} ratio for muon alpha sticking X-rays in muon catalyzed d-t fusion at the RIKEN-RAL Muon Facility  

Energy Technology Data Exchange (ETDEWEB)

At the RIKEN-RAL Muon Facility, {mu}{sup -} to {alpha} sticking K{sub {beta}} X-rays were observed for the first time taking advantage of the pulsed beam structure. The precision of the present measurements was insufficient to distinguish between theoretical models, however the observed K{sub {beta}}/K{sub {alpha}} X-ray intensity ratio tends to be smaller than most of these theoretical predictions.

1999-06-15

441

L-subshell and total M-shell X-ray production cross sections of Ta, W, Pt, Au, Pb and Bi by 0.7-2.4 MeV protons  

International Nuclear Information System (INIS)

The L-subshell and total M-shell X-ray production cross sections of Ta, W, Pt, Au, Pb and Bi have been measured by protons of energy between 0.7 and 2.4 MeV. The obtained results for X-ray production cross sections have been compared with the existing experimental data, prediction of the ECPSSR theory and also with fitted empirical cross sections of Strivay and Weber.

2006-06-01

442

Emission Line Spectra in the Soft X-Ray Region 20-75 (Angstrom)  

Energy Technology Data Exchange (ETDEWEB)

As part of a project to complete a comprehensive catalogue of astrophysically relevant emission lines in support of new-generation X-ray observatories using the Lawrence Livermore electron beam ion traps EBIT-I and EBIT-II, we studied emission lines of argon and sulfur in the soft X-ray and extreme ultraviolet region. Here we present observations of Ar IX through Ar XVI and S VII through S XIV between 20 and 75 {angstrom} to illustrate our work.

2002-06-18

443

Applications of X-ray scattering in pharmaceutical science  

British Library Electronic Table of Contents (United Kingdom)

The use of X-ray scattering techniques in pharmaceutical science is increasing, in part through increased collaborations with the materials science community, and through increased availability of instrumentation, particularly synchrotron sources. The ability to understand not only the biopharmaceutical outcome, but also arguably, more importantly, the structural aspects of drugs and drug delivery systems, is essential to progressing pharmaceutical science; this review serves as an introduction to the major techniques and the wide range of areas in which X-ray scattering may be applied in understanding and controlling structure in pharmaceutical systems.

2011-01-01

444

The ternary system cerium-palladium-silicon  

International Nuclear Information System (INIS)

Phase relations in the ternary system Ce-Pd-Si have been established for the isothermal section at 800 deg. C based on X-ray powder diffraction and EMPA techniques on about 130 alloys, which were prepared by arc-melting under argon or powder reaction sintering. Eighteen ternary compounds have been observed to participate in the phase equilibria at 800 deg. C. Atom order was determined by direct methods from X-ray single-crystal counter data for the crystal structures of #tau#_8-Ce_3Pd_4Si_4 (U_3Ni_4Si_4-type, Immm; a=0.41618(1), b=0.42640(1), c=2.45744(7) nm), #tau#_1_6-Ce_2Pd_1_4Si (own structure type, P4/nmm; a=0.88832(2), c=0.69600(2) nm) and also for #tau#_1_8-CePd_1_-_xSi_x (x=0.07; FeB-type, Pnma; a=0.74422(5), b=0.45548(3), c=0.58569(4) nm). Rietveld refinements established the atom arrangement in the structures of #tau#_5-Ce_3PdSi_3 (Ba_3Al_2Ge_2-type, Immm; a=0.41207(1), b=0.43026(1), c=1.84069(4) nm) and ...

2009-09-01

445

X-ray Emission as a Probe of the Wind-Driven Shock in WR 140  

Science.gov (United States)

single star evolution. To understand the evolution of massive stars and their role in shaping the galaxy, understanding of the distribution of ...

446

Trace analysis in cadmium telluride by heavy ion induced X-ray emission and by SIMS  

International Nuclear Information System (INIS)

The possibilities of using both selective heavy ion induced X-ray emission and secondary ion mass spectroscopy (SIMS), for the identification of impurities present at low concentrations in cadmium telluride are examined. The relative concentrations of the impurities along CdTe crystals have been determined by exciting the X-ray emission of the elements in several slices with Ar and Kr ions and by comparing the relative characteristic X-ray emission yields. As a consequence of the quasimolecular inner shell ionization mechanism in heavy ion-atom collisions, Ar and Kr ions allow a strong excitation of the main impurities seen by SIMS namely Si, Cl and Ge, As, with only a minor contribution of Cd and Te. From the changes of the concentrations of the various impurities along the crystal, informations about segregation coefficients and compensation can be obtained.

2007-02-01

447

Thermal and Electromigration-Induced Strains in Polycrystalline Films and Conductor Lines X-ray Microbeam Measurements and Analysis  

CERN Document Server

Thermal and Electromigration-Induced Strains in Polycrystalline Films and Conductor Lines

2006-01-01

449

The Effects of Long Term Storage on Special Purpose Lead ...  

Science.gov (United States)

... Special Purpse Lead Azide Lot #I3A-4-62 ... Standard X-ray techniques are not sufficiently sensitive ... the National Bureau of Standards, and examined ...

1972-10-01

450

Structure and morphology changes during nylon 66 fiber deformation via synchrotron x-ray scattering techniques  

Energy Technology Data Exchange (ETDEWEB)

Morphological and structural changes of nylon 66 were evaluated during a continuous heat-draw process. Results are discussed.

1996-12-31

451

Strong-interaction effect measurements in sigma hyperonic atoms of W and Pb  

Energy Technology Data Exchange (ETDEWEB)

Strong-interaction effects have been observed in the x-ray spectra of atoms formed with [Sigma][sup [minus

1993-03-01

452

Recent progress in energy-filtered high energy X-ray photoemission electron microscopy using a Wien filter type energy analyzer  

International Nuclear Information System (INIS)

Energy-filtered X-ray photoemission electron microscopy (EXPEEM) is a microscopy technique which has the potential to provide surface chemical mapping during surface chemical processes on the nanometer scale. We studied the possibilities of EXPEEM using a Wien filter type energy analyzer in the high energy X-ray region above 1000 eV. We have successfully observed the EXPEEM images of Au islands on a Ta sheet using Au 3d_5_/_2 and Ta 3d_5_/_2 photoelectron peaks which were excited by 2380 eV X-rays emitted from an undulator (BL2A) at Photon Factory. Our recent efforts to improve the sensitivity of the Wien filter energy analyzer will also be discussed.

2004-10-15

453

Radiation exposure to patients during hepatic interventional procedure  

International Nuclear Information System (INIS)

Objective: To investigate the X-ray radiation dose patients dealt with the hepatic intervention. Methods: Thermoluminescence and tissue-equivalent anthropomorphic phantom were used to measure the X-ray radiation dose in patients dealt with the hepatic intervention in 85 patients. Results: The peak skin dose in the patients who accepted hepatic intervention was from 179.95 to 1759.00 mGy, effective dose approached 29.22 mSv (male), 29.27 mSv (female). Conclusion: Hepatic intervention is now regarded as an important therapeutic method for liver cancer. However, the patients were exposed to too much X-ray radiation during interventional procedures. Some more effective protection should be taken to decrease the X-ray radiation dose accepted by patients. (authors)

2005-05-01

454

Pulse source of electron and X-ray radiations of subnanosecond duration  

International Nuclear Information System (INIS)

The time and dose characteristics of the electron and X-ray radiations of a tube, connected to a subnanosecond mega volt accelerator, are measured. By the pulse of the accelerating voltage of #>=# 600 kV with duration of #approx =# 0.3 ns the tube generates approximately 5 x 10"1"2 electrons pulse. The current amplitude equals approximately 5 kA/pulse and the radiation dose-about 5 kGy/pulse. The X-ray radiation dose from the tantalum external target constitutes 0.15 Gy/pulse. The prototypes of the electron and X-ray tubes sufficiently lower volumes, opening new applications in the technique and medicine, are developed

455

Particle and X-ray damage in pn-CCDs  

Energy Technology Data Exchange (ETDEWEB)

The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.

2000-01-11

456

On the Z-dependence of K#alpha#_1/K#beta#_1 X-ray intensity ratio  

International Nuclear Information System (INIS)

1976. Germany Ramaswamy, MK Birla Inst. of Tech. and Science, Pilani

1976-03-29

457

Magnetospheric particle acceleration and X-ray emission of pulsars  

CERN Document Server

The available data on isolated X-ray pulsars, their wind nebulae, and the supernova remnants which are connected to some of these sources are analyzed. It is shown that electric fields of neutron stars tear off charged particles from the surface of neutron star and trigger the acceleration of particles. The charged particles are accelerated mainly in the field of magneto-dipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magneto-dipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.

2007-01-01

458

Luminescence and x-ray absorption measurements of persistent SrAl2O4:Eu,Dy powders: Evidence for valence state changes  

Science.gov (United States)

The development of new efficient afterglow phosphors is currently hampered by a limited understanding of the persistent luminescence mechanism. Radioluminescence (RL) and x-ray absorption measurements on the persistent phosphor SrAl2O4:Eu,Dy were combined to reveal possible valence state changes for the rare earth (co)dopants. Traps in the phosphor material are quickly filled when exposing thermally emptied SrAl2O4:Eu,Dy powder to x rays. On the same time scale a partial oxidation of Eu2+ to Eu3+ is observed by x-ray absorption near-edge spectroscopy (XANES), while for the trivalent dysprosium the valence state remains unchanged. The impact of these observations on the recently proposed models for persistent luminescence is discussed.

2011-08-01

459

Koji Mukai's Bibliography - Astrophysics Science Division Staff ...  

Science.gov (United States)

Jul 25, 2011 ... Koji Mukai's Bibliography. Invited Reviews. Mukai, K. 1994, "ASCA PV Phase Observations of Cataclysmic Variables," in "New Horizon of X-ray ...

460

Ion-induced M X-ray emission from heavy lanthanides  

International Nuclear Information System (INIS)

Thick targets of several heavy lanthanide (Ho-Lu) compounds were bombarded by protons and "3He ions of 3 MeV/amu, and M_#alpha# and M_#beta# X-rays were measured with a crystal spectrometer. Ionization probabilities of the N-shell for zero impact parameter were obtained from the X-ray intensity ratio for proton and "3He ion impacts. A shell dependence of the ionization probability was found in a scaling plot. X-ray spectra of lanthanide compounds were compared and no chemical effect was observed. This result is considered to be due to the fact that the main component of M_#alpha# and M_#beta# lines is for radiative transition after the refilling of the 4f orbit (3d"-"14f"n"+"1 #-># 4f"n) where n denotes the number of 4f electrons of the target atom before ionization. (orig.).

1987-12-01

462

High-energy x-ray microscopy techniques for laser-fusion plasma research at the National Ignition Facility  

Energy Technology Data Exchange (ETDEWEB)

Multi-kilo-electron-volt x-ray microscopy will be an important laser-produced plasma diagnostic at future megajoule facilities such as the National Ignition Facility (NIF). However, laser energies and plasma characteristics imply that x-ray microscopy will be more challenging at NIF than at existing facilities. We use analytical estimates and numerical ray tracing to investigate several instrumentation options in detail, and we conclude that near-normal-incidence single spherical or toroidal crystals may offer the best general solution for high-energy x-ray microscopy at NIF and similar large facilities. Apertured Kirkpatrick{endash}Baez microscopes using multilayer mirrors may also be good options, particularly for applications requiring one-dimensional imaging over narrow fields of view. {copyright} 1998 Optical Society of America

1998-04-01

463

Future instrumentation for the study of the Warm-Hot Intergalactic Medium  

CERN Document Server

We briefly review capabilities and requirements for future instrumentation in UV- and X-ray astronomy that can contribute to advancing our understanding of the diffuse, highly ionised intergalactic medium.

2008-01-01

464

Feasibility analysis for attosecond X-ray pulses at FERMI@ELETTRA free electron laser  

Energy Technology Data Exchange (ETDEWEB)

We present preliminary analysis for the feasibility of the attosecond x-ray pulses at a proposed FERMI@ELETTRA free electron laser (FEL) [1]. In part 1 we restrict ourselves to minimal modifications to the proposed FEL and consider a scheme for attosecond x-ray production which can be qualified as a small add-on to a primary facility. We demonstrate that at 5-nm wavelength our scheme is capable for production of pulses with an approximate duration of 100 attoseconds at approximately 2 MW peak power and with an absolute temporal synchronization to a pump laser pulse. In part 2 we propose to use an FEL amplifier seeded by a VUV signal and to follow it by the scheme for attosecond x-ray production described in part 1.

2004-09-01

465

FUV and X-ray absorption in the Warm-Hot Intergalactic Medium  

CERN Document Server

The Warm-Hot Intergalactic Medium (WHIM) arises from shock-heated gas collapsing in large-scale filaments and probably harbours a substantial fraction of the baryons in the local Universe. Absorption-line measurements in the ultraviolet (UV) and in the X-ray band currently represent the best method to study the WHIM at low redshifts. We here describe the physical properties of the WHIM and the concepts behind WHIM absorption line measurements of H I and high ions such as O VI, O VII, and O VIII in the far-ultraviolet and X-ray band. We review results of recent WHIM absorption line studies carried out with UV and X-ray satellites such as FUSE, HST, Chandra, and XMM-Newton and discuss their implications for our knowledge of the WHIM.

2008-01-01

466

Evaluation of diagnostic digital radiography of the chest in comparison with conventional chest x-ray films  

International Nuclear Information System (INIS)

Digital radiography for diagnosis of chest diseases using Fuji Computed Radiography (FCR) was evaluated. The results were as follows; 1. Compared to the conventional chest X-ray films, various types of image enhancement could be made by manipulation of the digital information such as tone conversion, spatial frequency modification etc. 2. Digital radiography lessens the X-ray exposure dose and will ultimately permit speedy transmission of image data from outlying clinics to central processing hospitals. 3. Digital radiographic images are useful in chest X-ray diagnosis especially in mass surveys for lung cancer and in primary care medicine because of its full imaging capability. (author).

1983-01-01

467

Electron-induced luminescence and x-ray spectrometer development  

Science.gov (United States)

Jan 22, 2011 ... dc.description.abstract, The progress in the development of a surface analysis tool based on the excitation of characteristic luminescence ...

468

Density Gradients for Isolation of Mononuclear Blood Cells for ...  

Science.gov (United States)

... to-continuum X-ray intensity ratio [5]. For ence in the means [7]. In addition, washing samples on thin films, the characteristic X- lymphocytes in NH ...

2011-05-15

470

Acceleration of particles in pulsar magnetosphere and the X-ray radiation  

CERN Document Server

The available data of single X-ray pulsars, their wind nebulae, and the SNRs which are connected to some of these sources are analysed. It is shown that electric field intensity of neutron stars tears off charged particles from the surface of neutron star and triggers the acceleration of particles. The charged particles are accelerated mainly in the field of magnetodipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magnetodipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.

2004-01-01

471

Method and system for determining depth distribution of radiation-emitting material located in a source medium and radiation detector system for use therein  

Energy Technology Data Exchange (ETDEWEB)

A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the detector as rays parallel to the detector axis of the detector. The collimator may be a hollow cylinder positioned so that its central axis is perpendicular to the upper surface of the large area ...

2003-03-04

472

Preparation, properties, and application characteristics of metastable layers of the Ti-Si-C-N system; Herstellung, Aufbau, Eigenschaften und Anwendungsverhalten von metastabilen Schichten aus dem System Ti-Si-C-N  

Energy Technology Data Exchange (ETDEWEB)

In the Ti-Si-C and Ti-Si-C-N systems, metastable layers were precipitated by means of non-reactive magnetron sputtering of hot-pressed two-phase TiC/SiC and TiN/SiC targets with 20 mole% and 50 mole% SiC. The preparation parameters were varied as follows: ion bombardment during precipitation (bias sputtering), substrate temperature, and annealing times when annealing amorphous 50%:50% TiC/SiC and 50%:50% TiN/SiC layers. Sputtering of targets containing 20% SiC was found to result in monophase fcc layers (NaCl structure). This was documented on the basis of X-ray and electron diffraction patterns. Direct precipitation of targets with 50 mole% SiC resulted in amorphous layers. Increasing the ion bombardment during accretion, raising the substrate temperature, and annealing amorphous 50%:50% TiC/SiC and 50%:50% TiN/SiC (layers precipitated directly) resulted in the crystallization of TiC and TiN nanocrystallites, respectively, imbedded in an amorphous SiC matrix. ...

1992-10-01

473

Rocky Mountain spotted fever in areas of high and low prevalence: survey for canine antibodies to spotted fever rickettsiae.  

Science.gov (United States)

Antibodies to Rickettsia rickettsii were detected by indirect immunofluorescence in sera from 149 of 467 dogs (32%) examined from 4 military installations located in Kentucky, North Carolina, Pennsylvania, and Virginia. The prevalence at individual installations ranged from 4.3% at Fort Knox, Ky, to 63.4% at Fort Bragg, NC. Most of the seropositive dogs were in the working and sporting groups of dogs. The difference in antibody prevalence between sexes was not significant. Serologic responses were related to R rickettsii infection, although antibodies to R montana also were detected in a few of the sera. Comparison of serodiagnostic methods indicated that the indirect fluorescent antibody test was more sensitive than was the indirect hemagglutination test for obtaining survey data on the prevalence of Rocky Mountain spotted fever in the area. PMID:6808878

1982-08-01

474

A miniaturized spatial temperature gradient capillary electrophoresis system with radiative heating and automated sample introduction for DNA mutation detection  

British Library Electronic Table of Contents (United Kingdom)

Abstract A miniaturized spatial temperature gradient CE system with automated sample introduction for DNA mutation detection was established. Continuous electrokinetic sample injection was achieved by combining an automated slotted vial array sample introduction device to the spatial temperature gradient CE system. The temperature gradient was produced by a radiative heating system with a single graphite block heater, and the stability of the temperature gradient was investigated. The temperature variation of each measure point was 0.12 0.21% RSD (n=7) within 6 h. A 14 cm Teflon AF coated silica capillary was used both as the separation channel and as the liquid core waveguide tube of fluorescence signal. Under a temperature gradient from 54.8 to 59.5 C, a low range control mutation standa...

2010-01-01

475

X-dosimetry of Tl(InS_2)_1_-_x(FeSe_2)_x single crystals  

International Nuclear Information System (INIS)

Tl(InS_2)_1_-_x(FeSe_2)_x single crystals (where x=0; 0.001; 0.005; 0.01 and 0.015) were grown by the Bridgman-Stockbarger method. Obtained single crystals were crystallized in monoclinic structure. The present paper deals with experimental results relative to X-ray dosimetric characteristics of the Tl(InS_2)_1_-_x(FeSe_2)_x solid solutions at 300 K. Installation URS-55a was the source of radiation. X-ray radiation dose (E) falling on the crystals is measured by the crystalline X-ray dosimeter DRGZ-02. The value of X-ray conductivity coefficient K_#sigma# characterising X-ray sensitivity is defined as K_#sigma#= (#sigma#_E-#sigma#_0)/E#sigma#_0. where #sigma#_E is conductivity under the effect of X-ray radiation by intensity E, #sigma#_0 is conductivity in the lack of radiation. Comparing X-ray dosimetric characteristics of TlInS_2 and ...

2003-09-15

476

Determination of Cinchona alkaloids and Vitamin B_6 by high-performance liquid chromatography with fluorescence detection  

International Nuclear Information System (INIS)

A simple and specific method has been developed for the simultaneous determination of the four major Cinchona alkaloids and their dihydroderivatives and pyridoxine hydrochloride (Vitamin B_6) by high-performance liquid chromatography (HPLC) with fluorescence detection (#lambda#_e_m=420 nm with #lambda#_e_x=330 nm). The chromatographic separation was performed on a Phenomenex Prodigy ODS column (5 #mu#m, 250 mmx3.2 mm i.d.), recommended for basic compounds, under isocratic reversed-phase conditions. The method allowed a good peak shape and an effective resolution of the tested compounds. The extraction of alkaloids from the Cinchona succirubra bark was carried out in mild and fast conditions (ambient temperature, 20 min) by ultrasonication. The procedure showed to be advantageous respect to a reference method, which involved Soxhlet extraction. The results were compared statistically by means of the Student's t-test and the variance ratio ...

2004-06-04

477

Z-dependence of photon induced L_#alpha#/L_l X-ray intensity ratio in some elements 73 #<=# Z #<=# 92  

International Nuclear Information System (INIS)

L_#alpha#/L_l X-ray intensity ratios have been measured in elements Ta, W, Au, Hg, Tl, Pb, Bi, Th and U using L-shell photoionization by 60 keV photons. The present results are found to agree with the calculated values of Scofield within experimental uncertainties. (author).

1983-11-21

478

X-ray generation by the Smith-Purcell effect  

International Nuclear Information System (INIS)

Smith-Purcell (S-P) radiation is produced when electrons graze the surface of a grating. Calculations based on the theory of diffraction radiation show that, given severe restrictions on e"--beam quality, S-P radiation is highly efficient. Efficient S-P x-ray generation requires relativistic e"- beams having a transverse momentum and dimension whose product approaches the Heisenberg uncertainty limit.

479

X-ray diffraction studies of palladium silicide thin films  

Energy Technology Data Exchange (ETDEWEB)

The solid state reaction between a Pd thin film and a Si substrate produces a single new phase, Pd/sub 2/Si, for temperatures <700/sup 0/C. When the substrate is a single crystal of (111) surface orientation, this process is particularly interesting because the silicide grows epitaxially. Growth of epitaxial interfacial Pd/sub 2/Si was the focus of this study using X-ray diffraction techniques.

1985-01-01

480

X-RAY MICROANALYSIS OF A RADIOACTIVE PARTICLE WITH THE AID OF THE ELECTRON MICROSCOPE  

Science.gov (United States)

A radioactive particle was analyzed to discover the composition of the inactive material of the particle. The method uses the x-ray line spectrum of the K series caused by electron irradiation of the particle in the electron microscope. Iron and aluminum or silicon (the last two could not be distinguished) were found as inactive components in the particle. (D.L.C.)

1962-07-28

481

Survey of radiation doses to patients from the diagnostic use of X-rays  

International Nuclear Information System (INIS)

The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).

1977-06-01

482

Structure analysis of ferrite in deformed pearlitic steel by means of X-ray diffraction method with synchrotron radiation  

Energy Technology Data Exchange (ETDEWEB)

Structure of ferrite in drawn pearlitic steel containing 0.9 mass% C was investigated with X-ray diffraction technique using synchrotron radiation. In the detailed analysis of diffraction peaks of ferrite during the drawing process, it was experimentally revealed that the transformation of ferrite from bcc to bct due to the supersaturation of carbon in ferrite of heavily drawn pearlitic steel.

2004-07-15

483

Structure analysis of ferrite in deformed pearlitic steel by means of X-ray diffraction method with synchrotron radiation  

International Nuclear Information System (INIS)

Structure of ferrite in drawn pearlitic steel containing 0.9 mass% C was investigated with X-ray diffraction technique using synchrotron radiation. In the detailed analysis of diffraction peaks of ferrite during the drawing process, it was experimentally revealed that the transformation of ferrite from bcc to bct due to the supersaturation of carbon in ferrite of heavily drawn pearlitic steel.

2004-07-01

484

Structural intermediates in the assembly of taxoid-induced microtubules and GDP-tubulin double rings: time-resolved X-ray scattering.  

UK PubMed Central (United Kingdom)

We have studied the self-association reactions of purified GDP-liganded tubulin into double rings and taxoid-induced microtubules, employing synchrotron time-resolved x-ray solution scattering. The...Full Text Available

1996-05-01

485

Soft X-ray spectra of amorphous hydrogenated silicon  

Energy Technology Data Exchange (ETDEWEB)

The Si-L X-ray emission spectrum of amorphous hydrogenated silicon (a-Si:H) is presented and discussed. For a qualitative interpretation of the measured spectra cluster calculations of pure Si clusters (SiSi4) and Si clusters with hydrogen (SiSi3H) have been performed using a simplified LCAO-X scheme. In general the level shifts caused by introduction of hydrogen are small compared with the valence band width.

1985-06-01

486

Radiation exposure of the population of the GDR by X-ray diagnostics  

International Nuclear Information System (INIS)

The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.

1986-01-01

487

K_#beta#/K_#alpha# X-Ray Intensity Ratio Studies on the Valence Electronic States of 3d-Transition Metals in some of their Compounds  

International Nuclear Information System (INIS)

Our studies on K#beta#/K#alpha# X-ray intensity ratios of some of the technologically important 3d-transition metal compounds have been reviewed. Comparison of the experimental results with single-configuration Dirac-Fock calculations provided important information on the valence states of the transition metals in various compounds, which can be helpful in understanding the nature of bonding in the compounds. (author)

2000-02-01

488

Is the Ksub(#beta#)/Ksub(#alpha#) X-ray intensity ratio dependent upon the energy of an inducing proton  

International Nuclear Information System (INIS)

Ksub(#beta#)/Ksub(#alpha#) X-ray intensity ratios have been measured for various elements between Z = 29 and Z = 79 for incident proton energies of 23.6, 32.1 and 43.6 MeV. The results yield no evidence for a variation in ratio with particle energy. (orig.).

1980-01-01

489

FLASH-the first soft x-ray free electron laser (FEL) user facility  

Energy Technology Data Exchange (ETDEWEB)

The free electron laser (FEL) FLASH at DESY in Hamburg is the first x-ray FEL ever built. Many new developments were necessary in order to exploit the unique properties of this novel light source for scientific experiments. The facility has constantly been improved and several major upgrades have been made or are currently underway. This paper reviews the main characteristics of the user facility as well as the major developments and upgrades.

2010-10-14

490

Comments on possible preferential order-disorder in A-15 compounds based upon Nb  

International Nuclear Information System (INIS)

The possible existence of preferential B-site disorder in A-15 compounds recently claimed on the basis of x-ray powder diffraction data but questioned from the viewpoint of known phase diagrams is examined for some Nb-based compounds of this type. It is concluded that x-ray powder data do not allow the determination of both order and compositional variables as suggested, and the latter must therefore be determined by some other method. (author).

491

Chemical sensitivity of the Ksub(. beta. )/Ksub(. cap alpha. ) x-ray intensity ratio for 3d elements  

Energy Technology Data Exchange (ETDEWEB)

Chemical influences on the relative Ksub(..beta..)/Ksub(..cap alpha..) x-ray intensity ratio up to five per cent were found for different chemical constitutions of Cr, Mn, Fe and Cu by very precise PIXE measurements. In the discussion of these effects, screening of 3p electrons by a varying 3d valence charge, as well as polarizational effects are of importance.

1982-12-28

492

Chemical sensitivity of the Ksub(#nu#)/Ksub(#alpha#) x-ray intensity ratio for 3d elements  

International Nuclear Information System (INIS)

Chemical influences on the relative Ksub(#nu#)/Ksub(#alpha#) x-ray intensity ratio up to five per cent were found for different chemical constitutions of Cr, Mn, Fe and Cu by very precise PIXE measurements. In the discussion of these effects, screening of 3p electrons by a varying 3d valence charge, as well as polarisational effects are of importance. (author).

1982-12-01

493

Chemical effects on L_#gamma#_1/L_#beta#_1 x-ray intensity ratio of molybdenum compounds  

International Nuclear Information System (INIS)

Chemical effects on the intensity ratio of LX-ray of molybdenum compounds irradiated by 11-keV electrons and by 3-MeV protons were studied using an x-ray crystal spectrometer. It was found that the intensity ratios of L_#gamma#_1/L_#beta#_1 markedly decrease with the increase of ionicity of molybdenum compounds, except for the case of metallic molybdenum. (author).

1987-06-01

494

Changes in the profile structure of the sarcoplasmic reticulum membrane induced by phosphorylation of the Ca2+ ATPase enzyme in the presence of terbium: a time-resolved x-ray diffraction study.  

UK PubMed Central (United Kingdom)

The design of the time-resolved x-ray diffraction experiments reported in this and an accompanying paper was based on direct measurements of enzyme phosphorylation using [gamma-32P]ATP that were employed...Full Text Available

1994-05-01

495

Calculated valence electronic structure of 3d metals for use in the X-ray intensity ratio studies  

Energy Technology Data Exchange (ETDEWEB)

3d occupation numbers of the transition elements corresponding to various types of atomic configurations are calculated by means of the linear muffin-tin orbital (LMTO) method. This data is used with the multiconfiguration Dirac-Fock (MCDF) X-ray intensity ratios to estimate the electron populations of the 3d metals in alloys.

2010-09-15

496

Calculated valence electronic structure of 3d metals for use in the X-ray intensity ratio studies  

International Nuclear Information System (INIS)

3d occupation numbers of the transition elements corresponding to various types of atomic configurations are calculated by means of the linear muffin-tin orbital (LMTO) method. This data is used with the multiconfiguration Dirac-Fock (MCDF) X-ray intensity ratios to estimate the electron populations of the 3d metals in alloys.

2010-09-01

497

A sample preparation for quantitative determination of magnesium in individual lymphocytes by electron probe X-ray microanalysis.  

Science.gov (United States)

We present a sample preparation method for measuring magnesium in individual whole lymphocytes by electron probe X-ray microanalysis. We use Burkitt's lymphoma cells in culture as the test sample and compare X-ray microanalysis of individual cells with atomic absorption analysis of pooled cell populations. We determine the magnesium peak-to-local continuum X-ray intensity ratio by electron probe X-ray microanalysis and calculate a mean cell magnesium concentration of 39 +/- 19 mmol/kg dry weight from analysis of 100 cells. We determine a mean cell magnesium concentration of 34 +/- 4 mmol/kg dry weight by atomic absorption analysis of pooled cells in three cell cultures. The mean cell magnesium concentrations determined by the two methods are not significantly different. We find a 10% coefficient of variation for both methods of analysis and a 30% coefficient of variation in magnesium concentration among ...

1986-01-01

498

A radiant temperature numerical method for laser-plasma diagnostic using SXRSC with absorption method  

International Nuclear Information System (INIS)

An numerical method was developed for measuring radiant temperature using a set of absorption-foils coupled to soft x ray streak camera, SXRSC, in laser plasma experiments. An numerical code, SCC, was given. An x-ray intensity ratio vs temperature was calculated for Parylene, C_3H_6, Mylar and Aluminium. A suitable range of the measuring temperature was discussed to some absorber.

1990-01-01