The possibilities of using both selective heavy ion inducedX-rayemission and secondary ion mass spectroscopy (SIMS), for the identification of impurities present at low concentrations in cadmium telluride are examined. The relative concentrations of the impurities along CdTe crystals have been determined by exciting the X-rayemission of the elements in several slices with Ar and Kr ions and by comparing the relative characteristic X-rayemission yields. As a consequence of the quasimolecular inner shell ionization mechanism in heavy ion-atom collisions, Ar and Kr ions allow a strong excitation of the main impurities seen by SIMS namely Si, Cl and Ge, As, with only a minor contribution of Cd and Te. From the changes of the concentrations of the various impurities along the crystal, informations about segregation coefficients and ...
The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-inducedX-rayemission) due to the strong absorption of the As and Se K{sub {alpha}} X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K{sub {alpha}} X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions ...
The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-inducedX-rayemission) due to the strong absorption of the As and Se K_#alpha# X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K_#alpha# X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be ...
The radionuclide X-ray fluorescence and particle inducedX-rayemission methods were used for rapid and nondestructive analysis of metallic glasses. The methods were compared for accuracy and precision with the atomic absorption method. Some results of the analyses of Fe_xNi_8_0_-_xB_2_0 materials are briefly reviewed. The distribution of elements along the width as well as the length and a qualitative analysis of the composition of material surfaces are considered. (author).
Radionuclide X-ray fluorescence and particle inducedX-rayemission methods were used for a rapid and nondestructive analysis of metallic glasses. The methods are compared in accuracy and precision with the atomic absorption method. Some results of analyses of Fe_xNi_8_0_-_xB_2_0 materials are briefly reviewed. The distribution of elements along the width and length, and a qualitative analysis of the composition of material surfaces are considered. (author) 3 refs.
The L-shell x-ray intensity ratios I(L_#beta#)/I(L_#alpha#) and I(L_#gamma#)/I(L_a_l_p_h_a) for elements with 73 #<=# Z #<=# 83 have been measured at photon incident energies of 17.8, 25.8 and 46.9 keV. The emitted x-rays were measured with a Si(Li) detector system. The results for Re, Pt and Tl are being reported for the first time. A comparison is made of the experimental results with the calculated values obtained by using the theoretical x-rayemission rates, subshell ionisation cross sections, subshell fluorescence yields and Coster-Kronig transition probabilities. The experimental results are in reasonable agreement with the theoretical values. (author).
Thick targets of several heavy lanthanide (Ho-Lu) compounds were bombarded by protons and "3He ions of 3 MeV/amu, and M_#alpha# and M_#beta# X-rays were measured with a crystal spectrometer. Ionization probabilities of the N-shell for zero impact parameter were obtained from the X-ray intensity ratio for proton and "3He ion impacts. A shell dependence of the ionization probability was found in a scaling plot. X-ray spectra of lanthanide compounds were compared and no chemical effect was observed. This result is considered to be due to the fact that the main component of M_#alpha# and M_#beta# lines is for radiative transition after the refilling of the 4f orbit (3d"-"14f"n"+"1 #-># 4f"n) where n denotes the number of 4f electrons of the target atom before ionization. (orig.).
The issue of beam-induced damage on diffractive hard X-ray optics is addressed. For this purpose a systematic study on the radiation damage induced by a high-power X-ray beam is carried out in both...Full Text Available
The study of imported ceramics found in Beirut and suspected to belong to north Syrian products will provide key evidence for the roles in trade of the various postulated centers in northern Syria and northern Lebanon. It is proposed that a comprehensive range of likely north Syrian products imported to Beirut will be chemically analyzed by PIXE (proton inducedX-rayemission) in order to characterize, compare and isolate the various regional production centers that supplied the city from the Persian to Byzantine periods. In this work, we were mainly focusing on the characterization of Amrit products, by using 3 MeV proton beam and Al funny filter, as X-ray absorber.
Plantago ovata Forsk - an economically important medicinal plant - was analyzed for trace elements and chlorophyll in a study of the effects of gamma radiation on physiological responses of the seedlings. Proton-inducedX-rayemission (PIXE) technique was used to quantify trace elements in unirradiated and gamma-irradiated plants at the seedling stage. The experiments revealed radiation-induced changes in the trace element and chlorophyll concentrations.
High interelectrode voltage peaks have been observed simultaneously with the emission of hard X-ray bursts from a flash X-ray tube. The magnitude of the voltage peaks may exceed twice the initial charging voltage. It has also been observed that the discharge emits bursts of X-and P-band microwaves radiation which are coincident with the emission of the hard X-ray bursts. The results indicate that the microwaves and X-rays have a common origin in discharge plasma movements and an acceleration model for electrons in the plasma is presented as one possible explanation of the observed phenomena.
Characterization of high temperature superconducting film and bulk samples has been carried out using 2 MeV [alpha]-particle Rutherford backscattering, 2.4 MeV proton elastic scattering, 2.4 MeV proton-inducedx-rayemission, 9 MeV proton induced [gamma]-ray emission and 100 MeV iodine elastic recoil detection analysis techniques. The objective was to compare different ion beam based techniques for: (i) compositional analysis; and (ii) consistency of the results obtained for samples prepared using similar preparation methodology. (author).
Thick targets of several heavy lanthanide (Ho-Lu) compounds were bombarded by protons and /sup 3/He ions of 3 MeV/amu, and M/sub ..cap alpha../ and M/sub ..beta../ X-rays were measured with a crystal spectrometer. Ionization probabilities of the N-shell for zero impact parameter were obtained from the X-ray intensity ratio for proton and /sup 3/He ion impacts. A shell dependence of the ionization probability was found in a scaling plot. X-ray spectra of lanthanide compounds were compared and no chemical effect was observed. This result is considered to be due to the fact that the main component of M/sub ..cap alpha../ and M/sub ..beta../ lines is for radiative transition after the refilling of the 4f orbit (3d/sup -1/4f/sup n+1/ -> 4f/sup n/) where n denotes the number of 4f electrons of the target atom before ionization.
We analyze archived Chandra and XMM-Newton X-ray observations of 536 Sloan Digital Sky Survey (SDSS) Data Release 5 (DR5) quasars (QSOs) at 1.7 <= z <= 2.7 in order to characterize the relative UV and X-ray spectral properties of QSOs that do not have broad UV absorption lines (BALs). We constrain the fraction of X-ray weak, non-BAL QSOs and find that such objects are rare; for example, sources underluminous by a factor of 10 comprise $\\la$2% of optically-selected SDSS QSOs. X-ray luminosities vary with respect to UV emission by a factor of $\\la$2 over several years for most sources. UV continuum reddening and the presence of narrow-line absorbing systems are not strongly associated with X-ray weakness in our sample. X-ray brightness is significantly correlated with UV emission line properties, so that relatively ...
Modern radiometric analytics demands a complex consideration of nuclear and electron shell processes, if more pretentious aims are envisaged. As an example the small variation of decay rates of radionuclides presents possibilities for information on chemical situations of decaying atoms. In principle this phenomenon is well known since many years, but now the situation is such that, e.g. in /sup 99m/Tc internal conversion, a full agreement of the difficult experiments and the respective theory was established. The secondary emission of X-rays as a consequence of high excitation of electron shells in combination with nuclear transitions supplies another example for a methodical progress of radiometry. Investigations on "5"1Cr as an electron capture nuclide have shown that chemically induced variations of the K/sub #alpha#/ to K/sub #beta#/ X-ray intensity ratio is at least qualitatively understood. ...
The handling of physical-nuclear techniques for the analysis of archaeological pieces it was carried out by first time in 1956 by the doctors Oppenheimer and Dodsom (in the United States); who wrote about the wide utilities of the neutron activation analysis (NAA), this technique requires of a nuclear reactor that could be considered like one a factory of thermal neutrons necessary to carry out this analysis. The first experiments in that were applied the NAA were on ceramic coming from the Mediterranean, in those that the relationships of the elements of sodium and manganese were determined to know their elementary composition and to identify the origin of their manufacture. Later on other study techniques were applied in archaeological materials, as the X-ray fluorescence, Moessbauer spectroscopy, scanning electron microscopy, PIXE analysis (particle inducedx-rayemission), among other, this last is ...
We present the X-ray properties of a sample of 17 radio sources observed with the Chandra X-ray Observatory as part of a project aimed at studying the X-rayemission from their radio jets. In this paper, we concentrate on the X-ray properties of the unresolved cores. The sample includes 16 quasars (11 core-dominated and 5 lobe-dominated) in the redshift range z=0.30--1.96, and one low-power radio-galaxy at z=0.064. No diffuse X-rayemission is present around the cores of the quasars, except for the nearby low-power galaxy that has diffuse emission on a scale and with a luminosity consistent with other FRIs. No high-amplitude, short-term variability is detected within the relatively short Chandra exposures. However, 1510-089 shows low-amplitude flux changes with a timescale of $\\sim$25 minutes. The ...
The use of the ratio of the characteristic intensity to the continuum background intensity (P/B ratio) of the X-ray spectrum for a quantitative ion microprobe (IMP) or PIXE (particle inducedX-rayemission) analysis of thin biological specimens was proposed previously. The IMP analysis of thick biological specimens is also of considerable practical use. In this paper, the possibility of using the P/B ratio to quantify minor elements in thick biological specimens is investigated. The epoxy resin based standards with gradual concentrations of KCNS up to 0.6 mol/kg and NBS bovine liver were analyzed by a 27 MeV {alpha} particle microprobe. The measured peak to background ratios (between 4.4 to 5.7 keV) agreed well with the theoretical calculations. The calculations showed that the concentration dependence of the P/B ratios was determined mainly by the absorption of X-rays in specimens. ...
Proton inducedX-rayemission (PIXE) and proton induced {gamma}-ray emission (PIGE) techniques are employed for the determination of essential and trace elements in some commonly used medicinal plants of north east India. Light elements such as Na, Mg, Al and P are determined by PIGE while medium Z elements such as K, Ca, Mn, Fe, Cu, Zn, Rb and Sr are determined by PIXE. Analysis is performed on pellets (thick targets) prepared using powders of the specimens which, in turn, are obtained following a series of processing steps. Plant based biological certified reference materials (CRMs) served as standards for quantification. These elements are found to be present in varying concentrations in the studied plants, with the contents of Mn and Zn being notably large in certain specimens. Medicinal properties possessed by these plants have been correlated with their elemental distribution.
Context: The colliding-wind binary Eta Car exhibits soft X-ray thermal emission that varies strongly around periastron, and non-thermal emission seen in hard X-rays and gamma-rays. Aims: To definitively identify Eta Car as the source of the hard X-rayemission, to examine how changes in the 2-10 keV band influence changes in the hard X-ray band, and to understand more clearly the mechanisms producing the non-thermal emission using new INTEGRAL observations obtained close to periastron. Methods: A Chandra observation encompassing the ISGRI error circle was analysed, and all other soft X-ray sources (including the outer shell of Eta Car itself) were discarded as likely counter-parts. New hard X-ray images of Eta Car were studied close to periastron, and compared to previous ...
A photon-inducedx-ray fluorescence method allowing the simultaneous determination of iron, copper, zinc, bromine and rubidium in human blood and blood plasma samples is described. The method is reliable and has a good sensitivity for a wide range of elements. (author).
We report the detection of X-ray pulsations with a period of ?315.87 ms from the 2009 XMM-Newton observation for the radio-quiet ?-ray pulsar, LAT PSR J0007+7303, centered in the supernova remnant CTA 1. The detected pulsed period is consistent with the ?-ray periodicity at the same epoch found with the Fermi Gamma-ray Space Telescope. The broader sinusoidal structure in the folded light curve of the X-rayemission is dissimilar to that of the ?-ray emission, and the phase of the peak is about 0.5 shifting from the peak in the ?-ray bands, indicating that the main component of the X-rays originates from different sites of the pulsar. We conclude that the main component of the X-ray pulsation is contributed by the thermal emission from the neutron star. Although with a significantly different characteristic age, PSR J0007+7303 is similar to ...
As part of a project to complete a comprehensive catalogue of astrophysically relevant emission lines in support of new-generation X-ray observatories using the Lawrence Livermore electron beam ion traps EBIT-I and EBIT-II, we studied emission lines of argon and sulfur in the soft X-ray and extreme ultraviolet region. Here we present observations of Ar IX through Ar XVI and S VII through S XIV between 20 and 75 {angstrom} to illustrate our work.
Recent X-ray and radio observations have identified a transient low-mass X-ray binary (LMXB) located only 0.1 pc in projection from the Galactic center, CXOGC J174540.0-290031. In this paper, we report the detailed analysis of X-ray and infrared observations of the transient and its surroundings. Chandra bservations detect the source at a flux of F_X = 2e-12 erg cm^-2 s^-1 (2-8 keV). After accounting for absorption both in the interstellar medium and in material local to the source, the implied luminosity of the source is only L_X = 4e34 erg/s (2-8 keV; D=8 kpc). However, the diffuse X-rayemission near the source also brightened by a factor of 2. The enhanced diffuse X-rayemission lies on top of a known ridge of dust and ionized gas that is visible infrared images. We interpret the X-rayemission ...
The effect of anode length and operating gas pressure on the x-rayemission from a nitrogen-filling modified plasma focus device has been investigated. The time-resolved investigation of xray was carried out by using a five-channel photodiode x-ray spectrometer. The maximum x-ray yield is seen to increase with the increase in the anode length from 110 to 125 mm. Further increase in the anode length to 130 mm causes the x-ray yields to decrease. The highest x-ray yield of 4.5 J into 4#pi# sr was found for 125 mm anode length, which is 0.2% of the input energy. The average x-ray photon energy was estimated by using half-value thickness method and found to be 8.4 keV. The electron temperature of the plasma was estimated to be around 3 keV by x-ray intensity ratio method. The ...
This paper describes Fuji computed radiography (FCR) of Fuji Film for NDT (non-destructive testing). Imaging plate (IP) is a two-dimensional detector of X-ray, and shows higher photographic sensitivity than X-ray film. The output emission of IP provides a good linear relationship to X-ray intensity in a wide intensity range. When this emission can be digitized, the X-ray intensity can be also digitized. IP is applied to NDT as an inspection using X-ray. FCR provides higher photographic sensitivity than the conventional X-ray film method, which results in one-fifth to one-twentieth of irradiation time. Images with stable density can be obtained independent of the intensity. Since IP has a wide dynamic range, the variation of X-ray intensity of 1:500 can be expressed in a single image by single shot. ...
We review the current status of resolved X-rayemission associated with extragalactic radio jets and hotspots. The primary question for any particular jet is to decide if the X-rays come from the synchrotron process or from inverse Compton scattering. There is considerable evidence supporting synchrotron emission for knots in the jets of FRI galaxies. For FRII terminal hotspots detected in the X-ray band, synchrotron self-Compton emission continues to provide viable models with one possible exception (so far). Inverse Compton scattering on photons of the cosmic microwave background is indicated for a few powerful jets, and is expected to be an important contributor if not the dominating mechanism for higher redshift objects. The application of a model generally yields physical parameters and in many cases, these include the Doppler boosting factor.
Jan 22, 2011 ... dc.description.abstract, The progress in the development of a surface analysis tool based on the excitation of characteristic luminescence ...
A miniature x-ray source utilizing a hot filament cathode. The source has a millimeter scale size and is capable of producing broad spectrum x-rayemission over a wide range of x-ray energies. The miniature source consists of a compact vacuum tube assembly containing the hot filament cathode, an anode, a high voltage feedthru for delivering high voltage to the cathode, a getter for maintaining high vacuum, a connector for initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is fabricated from highly x-ray transparent materials, such as sapphire, diamond, or boron nitride.
We propose and analyze a novel regenerative amplifier free electron laser (FEL) to produce fully coherent x-ray pulses. The method makes use of narrow-bandwidth Bragg crystals to form an x-ray feedback loop around a relatively short undulator. Self-amplified spontaneous emission (SASE) from the leading electron bunch in a bunch train is spectrally filtered by the Bragg reflectors and is brought back to the beginning of the undulator to interact repeatedly with subsequent bunches in the bunch train. The FEL interaction with these short bunches not only amplifies the radiation intensity but also broadens its spectrum, allowing for effective transmission of the x-rays outside the crystal bandwidth. The spectral brightness of these x-ray pulses is about two to three orders of magnitude higher than that from a single-pass SASE FEL.
Oxide superconducting thin films were irradiated with X-rays and ultra-violet (UV) light, and induced radiation effects on electrical and chemical properties were examined by transport measurement, X-ray diffraction analysis (XRD), diamagnetization measurement and X-ray photoemission spectroscopy (XPS). After irradiation for ErBa_2Cu_3O_x films with X-rays emitted from a Rh tube for 100 hours, superconductivity was remarkably damaged, destroying the zero-resistance state. The UV-light irradiation for Bi_2Sr_2CaCu_2O_x films was performed in He gas of about 500 Pa with a low pressure mercury lamp. The superconductivity was gradually degraded with the UV irradiation time up to 70 minutes. In both cases, adequate oxygen-annealing treatments restored superconductivity. The X-ray photoemission spectra showed that the mean Cu valence of the films was decreased ...
The peak flux relationship between hard X-rays and microwaves from solar flares is studied using about 400 events simultaneously recorded with the hard X-ray burst spectrometer on the SMM satellite and the Nobeyama 17 GHz radiometer. The data indicate that the hard X-ray and microwave peak fluxes correlate best for X-ray energies of less than about 80 keV for impulsive flares and greater than about 360 keV for extended flares. By postulating that electrons responsible for microwave emission at 17 GHz are those emitting hard X-rays at these photon energies, it is concluded that: (1) in impulsive flares, microwaves at about 20 GHz are emitted mainly by electrons of less than about 200 keV from a layer through which the electrons stream down into the thick-target hard X-ray source; and (2) in extended flares, microwaves are emitted mainly by ...
Fe-doped TiO2 hollow spheres (Fe-THs) were synthesized by sol?gel process using carbon spheres as templates. The prepared samples were characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM), UV?vis diffuse reflectance spectrum (DRS), N2 adsorption?desorption isotherms, Electron paramagnetic resonance (EPR) spectroscopy and Photoluminescence emission spectroscopy (PL). UV?vis spectra showed that Fe3+ doping could extend the absorption edge to the visible region. EPR spectra showed that Fe3+ was incorporated into the crystal lattice of TiO2, which could inhibit the recombination of photo-induced electron?hole pairs and improve the photocatalytic activity. The photocatalytic activities of the prepared samples were evaluated for the degradation of dye Reactive Brillia...
This paper reports the chemical compositions of chicken-blood stone Ji Xue Shi measured by Proton InducedX-rayEmission (PIXE). The experimental result show that for the red portion of chicken-blood stone, the concentration of Hg is as high as 20 wt%, and the concentration of S can be above 10 wt%. For the non-red portion the main chemical compositions are Al{sub 2}O{sub 3} and SiO{sub 2}. The obtained chemical compositions are close to those of kaolinite for Balin chicken-blood stone, and of pyrophyllite for Changhua chicken-blood stone, respectively. So far many Changhua chicken-blood stones and Balin chicken-blood stones were found in China, the PIXE method can be used to explore the provenance of available chicken-blood stones. (author)
We have studied the self-association reactions of purified GDP-liganded tubulin into double rings and taxoid-induced microtubules, employing synchrotron time-resolved x-ray solution scattering. The...Full Text Available
Coal is the most abundant available fossil fuel in Australia and provides a substantial part of energy needs. It is used for power generation, to supply energy to industry as well as for domestic requirements. Analysis of trace elements (the elements present in coal in ppm/ppb level) during combustion of coal in very important. Trace elements, like heavy metals such as arsenic, selenium, and chromium etc. are hazardous to the environment and some of them have carcinogenic potency. In the near future more stringent limits may be proposed for such elements generated from combustion process, such as coal combustion in power plants. Hence analysis and assessment of the emissions of these elements is essential at this stage. The first step towards reducing any impacts of trace elements is to have accurate quantitative analysis. Analysis of coal, bottom ash and fly ash collected from five different power stations across Australia was carried out to study the quantity and ...
The results of studies of the time-resolved luminescence of self-trapped excitons (STE) with different multiplicity as well as the X-rayemission in oriented BeO crystals under excitation in the vicinity of the 1 s Be photoabsorption edge are presented. The branching of the electronic excitations relaxation depends strongly on the crystal orientation after the inner-shell excitation. The common features between the processes of the STE luminescence and resonantly excited X-ray fluorescence have been discussed.
The quantitative estimation of various trace element concentrations in medicinal plants is necessary for determining their effectiveness in treating various diseases and for understanding their pharmacological action. Elemental concentrations of some selected medicinal plants of north east India was measured by proton inducedX-rayemission (PIXE) and proton induced {gamma}-ray emission (PIGE) techniques. PIXE measurements were carried out using 2.4 MeV collimated protons from the 3 MV tandetron accelerator of NCCCM, Hyderabad (India) while the PIGE measurements were carried out using 3 MeV protons from the same accelerator in the same laboratory. Accuracy and precision of the techniques were assured by analyzing certified reference materials in the same experimental conditions. Various elements of biological importance in man's metabolism were found to be present in ...
Considering the hardware characteristics of the laser-induced plasma X-ray source and the limitations of the conventional cone-beam reconstruction algorithm, a general cone-beam reconstruction algorithm has been developed at our laboratory, in which the motion locus of the X-ray source is an arbitrary curve corresponding to at least a 2{pi} continuous horizontal angular displacement in the coordinate system of the specimen. The preliminary simulation shows that the general cone-beam reconstruction algorithm consistently results in visually satisfactory images.
Considering the hardware characteristics of the laser-induced plasma X-ray source and the limitations of the conventional cone-beam reconstruction algorithm, a general cone-beam reconstruction algorithm has been developed at our laboratory, in which the motion locus of the X-ray source is an arbitrary curve corresponding to at least a 2{pi} continuous horizontal angular displacement in the coordinate system of the specimen. The preliminary simulation shows that the general cone-beam reconstruction algorithm consistently results in visually satisfactory images.
Context. The high energies of protostellar jets, implied by recent observations of X-rays from such flows, came very much as a surprise. Inferred shock velocities are considerably higher than what was previously known, hence putting even larger energy demands on the driving sources of the jets. The statistics of X-ray emitting jets are still poor, yet a few cases exist which seem to imply a correlation between the presence of HeI 1.0830 mu emission and X-ray radiation in a given source. Aims. This tentative correlation needs confirmation and explanation. If the jet regions of HeI 1.0830 mu emission are closely associated with those producing X-rays, high resolution infared spectroscopy can be used to observationally study the velocity fields in the hot plasma regions of the jets. This would provide the necessary evidence to test and further develop theoretical ...
AbstractX-ray diffraction analysis of pressure-induced structural changes in the Aequorea yellow fluorescent protein Citrine reveals the structural basis for the continuous...Full Text Available
The Si-L X-rayemission spectrum of amorphous hydrogenated silicon (a-Si:H) is presented and discussed. For a qualitative interpretation of the measured spectra cluster calculations of pure Si clusters (SiSi4) and Si clusters with hydrogen (SiSi3H) have been performed using a simplified LCAO-X scheme. In general the level shifts caused by introduction of hydrogen are small compared with the valence band width.
Radionuclide x-ray fluorescence analysis was used for the determination of Y, Ba and Cu in thin high-temperature superconducting films. Atomic emission ICP spectrometry was used to estimate the precision and accuracy of analytical results. Reasonable agreement between both methods was obtained when a polynomial calibration curve was applied. (author) 4 refs.; 4 tabs.
Radionuclide X-ray fluorescence analysis was used for the determination of Cu, Y and Ba in very thin high-temperature superconducting films. The precision of the method is better than 3% for about 1 #mu#m thick films. The atomic emission ICP spectrometry was used to testify results of XRF analysis. An acceptable agreement of both methods was obtained. (author) 4 refs.; 2 tabs.
The available data on isolated X-ray pulsars, their wind nebulae, and the supernova remnants which are connected to some of these sources are analyzed. It is shown that electric fields of neutron stars tear off charged particles from the surface of neutron star and trigger the acceleration of particles. The charged particles are accelerated mainly in the field of magneto-dipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magneto-dipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.
L_#alpha#/L_l X-ray intensity ratios have been measured in elements Ta, W, Au, Hg, Tl, Pb, Bi, Th and U using L-shell photoionization by 60 keV photons. The present results are found to agree with the calculated values of Scofield within experimental uncertainties. (author).
Ksub(#beta#)/Ksub(#alpha#) X-ray intensity ratios have been measured for various elements between Z = 29 and Z = 79 for incident proton energies of 23.6, 32.1 and 43.6 MeV. The results yield no evidence for a variation in ratio with particle energy. (orig.).
The design of the time-resolved x-ray diffraction experiments reported in this and an accompanying paper was based on direct measurements of enzyme phosphorylation using [gamma-32P]ATP that were employed...Full Text Available
The nature of the hard X-ray source XSSJ12270-4859 is still unclear though it was claimed to be a magnetic Cataclysmic Variable. We here present a broad-band X-ray and gamma ray study based on a recent XMM-Newton observation and archival INTEGRAL and RXTE data. From the Fermi/LAT 1-year point source catalogue, we tentatively associate XSSJ12270-4859 with 1FGLJ1227.9-4852, a source of high energy gamma rays with emission up to 10GeV. We complement the study with UV photometry from XMM-Newton and ground-based optical and near-IR photometry. The X-rayemission is highly variable showing flares and intensity dips. The X-ray flares consist of flare-dip pairs. Flares are also detected in the UV range but not the dips. Aperiodic dipping behaviour is also observed during X-ray quiescence but not in the UV. The 0.2-100keV spectrum is featureless and ...
We present a Hubble Space Telescope image of the FRII radio galaxy 3C 401, obtained at 1.6 microns with the NICMOS camera in which we identify the infrared counterpart of the brightest region of the radio jet. The jet has a complex radio structure and brightens where bending occurs, most likely as a result of relativistic beaming. We analyze archival data in the radio, optical and X-ray bands and we derive its spectral energy distribution. Differently from all of the previously known optical extragalactic jets, the jet in 3C401 is not detected in the X-rays even in a long 48ksec X-ray Chandra exposure and the infrared emission dominates the overall SED. We propose that the dominant radiation mechanism of this jet is synchrotron. The low X-rayemission is then caused by two different effects: i) the lack of any strong external photon field and ii) the shape of ...
Radionuclides exhibiting in decaying a strong interaction between nucleus and electron shell (especially electron capture and internal conversion) are, in principle, sensitive to their chemical surroundings. Consequently, they can be used to yield chemical information after an appropriate labelling procedure. The information can be extracted from the decay rate variation as well as from their X-rayemission as a response to an inner-shell vacancy creation during nuclear deexcitation. As an example of the former method the relationship between the decay rate of /sup 99m/Tc and the chemical structures of pertechnetate and bis(meso-dimercapto-succinate)oxotechnetate(V) is considered. Lower expectations with respect to measuring techniques are associated with the observation of X-rayemission. For a number of elements (especially 3d transition elements) the K/sub ..cap alpha..//K/sub ..beta../ ...
Radionuclides exhibiting in decaying a strong interaction between nucleus and electron shell (especially electron capture and internal conversion) are, in principle, sensitive to their chemical surroundings. Consequently, they can be used to yield chemical information after an appropriate labelling procedure. The information can be extracted from the decay rate variation as well as from their X-rayemission as a response to an inner-shell vacancy creation during nuclear deexcitation. As an example of the former method the relationship between the decay rate of /sup 99m/Tc and the chemical structures of pertechnetate and bis(meso-dimercapto-succinate)oxotechnetate(V) is considered. Lower expectations with respect to measuring techniques are associated with the observation of X-rayemission. For a number of elements (especially 3d transition elements) the K/sub #alpha#//K/sub #betta#/ ...
We examine the accretion properties in a sample of 42 hard (3-60keV) X-ray selected nearby broad-line AGNs. The energy range in the sample is harder than that usually used in the similar previous studies. These AGNs are mainly complied from the RXTE All Sky Survey (XSS), and complemented by the released INTEGRAL AGN catalog. The black hole masses, bolometric luminosities of AGN, and Eddington ratios are derived from their optical spectra in terms of the broad H$\\beta$ emission line. The tight correlation between the hard X-ray (3-20keV) and bolometric/line luminosity is well identified in our sample. Also identified is a strong inverse Baldwin relationship of the H$\\beta$ emission line. In addition, all these hard X-ray AGNs are biased toward luminous objects with high Eddington ratio (mostly between 0.01 to 0.1) and low column density ($<10^{22} \\mathrm{cm^{-2}}$), which is ...
We present the results of an ongoing project to use the X-ray observations of Type Ia Supernova Remnants to constrain the physical processes involved in Type Ia Supernova explosions. We use the Tycho Supernova Remnant (SN 1572) as a benchmark case, comparing its observed spectrum with models for the X-rayemission from the shocked ejecta generated from different kinds of Type Ia explosions. Both the integrated spectrum of Tycho and the spatial distribution of the Fe and Si emission in the remnant are well reproduced by delayed detonation models with stratified ejecta. All the other Type Ia explosion models fail, including well-mixed deflagrations calculated in three dimensions.
M shell x-ray production cross sections in thick targets of Pb, Th and U by K x-rays of Rb, Nb and Mo respectively have been measured. As the incident K x-ray energies are above the L_3 edge but below L_2 edge energies of the respective target elements under reference, the M x-rays are produced not only due to direct interaction of incident photons with M shell electrons but also due to the shift of the L_3 subshell vacancies to the M shell. The experiment has been performed using a double reflection geometrical setup with a 1 Curie"2"4"1Am gamma ray source and a Si (Li) x-ray spectrometer. The measured values have been compared with those calculated using known values of M and L_3 subshell photoionisation cross sections and fluorescence yields etc., wherever possible. The component of the percentage contribution due to shift of L_3 subshell vacancies to M shell to the total M shell ...
Observations of the Type II-P (plateau) Supernova (SN) 1999em and Type IIn (narrow emission line) SN 1998S have enabled estimation of the profile of the SN ejecta, the structure of the circumstellar medium (CSM) established by the pre-SN stellar wind, and the nature of the shock interaction. SN 1999em is the first and only Type II-P detected at both X-ray and radio wavelengths. It is the least radio luminous and one of the least X-ray luminous SN ever detected (except for the unusual and very close SN 1987A). The Chandra X-ray data indicate non-radiative interaction of SN ejecta with a power-law density profile (rho \\propto r^{-n} with n ~ 7) with a pre-SN wind with a low mass loss rate of ~2 \\times 10^{-6} Msun/yr for a wind velocity of 10 km/sec, in close agreement with radio mass-loss rate estimates. The Chandra data show an unexpected, temporary rise in the 0.4--2.0 keV X-ray ...
We review X-ray plasma diagnostics based on the line ratios of He-like ions. Triplet/singlet line intensities can be used to determine electronic temperature and density, and were first developed for the study of the solar corona. Since the launches of the X-ray satellites Chandra and XMM-Newton, these diagnostics have been extended and used (from CV to Si XIII) for a wide variety of astrophysical plasmas such as stellar coronae, supernova remnants, solar system objects, active galactic nuclei, and X-ray binaries. Moreover, the intensities of He-like ions can be used to determine the ionization process(es) at work, as well as the distance between the X-ray plasma and the UV emission source for example in hot stars. In the near future thanks to the next generation of X-ray satellites (e.g., Astro-H and IXO), higher-Z He-like lines (e.g., iron) will be resolved, ...
This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The authors investigated the evolution and radiation characteristics of individual neutron stars and stellar systems. The work concentrated on phenomena where new techniques and observations are dramatically enlarging the understanding of stellar phenomena. Part of this project was a study of x-ray and gamma-ray emission from neutron stars and other compact objects. This effort included calculating the thermal x-rayemission from young neutron stars, deriving the radio and gamma-ray emission from active pulsars and modeling intense gamma-ray bursts in distant galaxies. They also measured periodic optical and infrared fluctuations from rotating neutron stars and search for high-energy TeV gamma rays from discrete celestial sources.
We present the results of a search for Extreme Ultraviolet emission in A4059, a cluster with an X-ray emitting cluster gas. Our analysis of Extreme Ultraviolet Explorer (EUVE) Deep Survey observations of this cluster shows that it is associated with diffuse EUV emission. Outside the central 2 arcmin radius the entire EUV emission detected is explained by the low energy tail of the X-ray emitting gas. Within the central 2 arcmin region of the cluster we find a deficit of EUV emission compared to that expected from the X-ray gas. This flux deficit is discussed in the context of the cluster's cooling flow. The results derived for A4059 are compared to EUVE results obtained for other clusters such as Coma, Virgo, A1795, and A2199. As part of the study we have carried out a detailed investigation of the stability of the EUVE Deep Survey detector ...
The emission of the plerion G21.5-0.9 appears more extended in Xrays than in radio. This is an unexpected result because it would imply that short-lived X-ray electrons may reach distances even larger than radio electrons. Applying an empirical relationship between dust scattering optical depth and photoelectric column density, the measured column density leads to a large optical depth at 1 keV, of about 1. Therefore we investigate the hypothesis that the detected halo be an effect of dust scattering, re-analyzing an Cal/PV XMM-Newton observation of G21.5-0.9 and critically examining it in terms of a dust scattering model. We also present a spectral analysis of a prominent extended feature in the northern sector of the halo.
{The determination of cluster masses is a complex problem that would be aided by information about the cluster shape and orientation (along the line-of-sight).} {It is in this context, that we have developed a scheme for identifying the intrinsic morphology and inclination of a cluster, by looking for the signature of the true cluster characteristics in the inter-comparison of the different deprojected emissivity profiles (that all project to the same X-ray brightness distribution) and by using SZe data when available.} {We deproject the cluster X-ray surface brightness profile under the assumptions of four different geometry and inclination configurations for the observed system; these 4 configurations correspond to four extreme geometry+inclination scenarios. The deprojection in question is performed by the non-parametric algorithm DOPING. The formalism is tested with model systems and then is applied to a sample of 24 ...
We use UV/optical and X-ray observations of 272 radio-quiet Type 1 AGNs and quasars to investigate the CIV Baldwin Effect (BEff). The UV/optical spectra are drawn from the Hubble Space Telescope, International Ultraviolet Explorer and Sloan Digital Sky Survey archives. The X-ray spectra are from the Chandra and XMM-Newton archives. We apply correlation and partial-correlation analyses to the equivalent widths, continuum monochromatic luminosities, and alpha_ox, which characterizes the relative X-ray to UV brightness. The equivalent width of the CIV 1549 emission line is correlated with both alpha_ox and luminosity. We find that by regressing l_UV with EW(CIV) and alpha_ox, we can obtain tighter correlations than by regressing l_UV with only EW(CIV). Both correlation and regression analyses imply that l_UV is not the only factor controlling the changes of EW(CIV); alpha_ox (or, equivalently, the soft ...
X-ray observations of the RSCVn system sigma Geminorum have been undertaken with the ROSAT observatory. Several spectra of very good signal-to-noise ratio were obtained. Spectral fitting using metal abundances amounting to 50% of solar values reveal two temperature components at 2 MK and 12 MK. Previous EXOSAT observations showed another component at 40 MK. Particular interest is focused on the temporal variations of the X-rayemission. It is found that variations occur on time scales ranging from years to hours and minutes.
Radionuclide X-ray fluorescence method with a Si/Li semiconductor detector and "2"3"8Pu exciting source was used in the study of Mn, Fe, Cu, Zn, and Pb content of solid emissions, raw and final materials of a brick factory. From the point of view of metal content, the working environment if the brick factory is safe for workers. (author) 2 refs.; 2 figs.; 1 tab.
Particle inducedX-rayemission (PIXE) technique has been employed to perform elemental analysis of K, Ca, Mn, Fe, Cu, Zn, Br and Sr for Syrian medicinal plants used traditionally to enhance the body immunity. Plant samples were prepared in a simple dried base. The results were verified by comparing with those obtained from both IAEA-359 and IAEA-V10 reference materials. Relative standard deviations are mostly within {+-}5-10% suggest good precision. A correlation between the elemental content in each medicinal plant with its traditional remedial usage has been proposed. Both K and Ca are found to be the major elements in the samples. Fe, Mn and Zn have been detected in good levels in most of these plants clarifying their possible contribution to keep the body immune system in good condition. The contribution of the elements in these plants to the dietary recommended intakes (DRI) has been evaluated. Advantages and ...
The electronic structure and surface interactions vapor-deposited Cu on single-crystal and polycrystalline Bi_2Ca/sub 1+//sub x//sub Sr>2-//sub x//sub Cu>2/O/sub 8+//sub y/ were studied using x-ray photoelectron spectroscopy. The results are compared to the Cu/YBa_2Cu_3O/sub 7-//sub x/ interface. Changes in the Cu 2p satellite emission indicate that the Cu adatoms do not disrupt Bi_2Ca/sub 1+//sub x/Sr/sub 2-//sub x/Cu_2O/sub 8+//sub y/ as extensively as YBa_2Cu_3O/sub 7-//sub x/. However, deposition of Cu induces changes in the Bi environment in the superconductor, and surface segregation of Bi metal was observed at high coverages. Core-level attenuation results suggests minimal outdiffusion of oxygen, in contrast with what is observed for Cu/YBa_2Cu_3O/sub 7-//sub x/.
The K-shell X-ray intensity ratios for W, Au, Tl, Pb, Bi, Th and U were measured at a photon incident energy of 121.9 keV from "5"7Co radionuclide. A comparison between the experimental results and the theoretically calculated values shows that the experimental results are, in general, higher than the theoretical values. The measured intensities are regarded to be reported for the first time. (author) 9 refs.; 1 tab.
Toroidal Alfven eigenmodes (TAE) destabilized by the pressure gradient of energetic alpha particles may expel the alpha particles before thermalization. TAE is important for tokamaks, and for helical systems (stellarators) as well. In CHS (compact helical system) TAE localized in the plasma core are destabilized when the plasma current is induced by co-injection of neutral beams. The observed TAE exhibits a ballooning nature. The internal structure of TAE was measured with a soft X-ray detector. The soft X-ray fluctuations level for TAE is too low to obtain the radial profiles of fluctuation intensities. (Tanaka, M.)
The proposed short wavelength coherent light source driven by the SLAC 3 km linac might be used to induce transitions between nuclear isomeric states. If an isotope were found with energetically adjacent isomeric states, one short-lived and one long-lived, and it were possible to separate and concentrate the long-lived species, and other nuclear and solid-state parameters were favorable, it might be possible to convert sufficient population to the short-lived state to realize [gamma]-ray lasing. Even if the x-ray intensity were insufficient, study of such driven transitions would be quite valuable.
The proposed short wavelength coherent light source driven by the SLAC 3 km linac might be used to induce transitions between nuclear isomeric states. If an isotope were found with energetically adjacent isomeric states, one short-lived and one long-lived, and it were possible to separate and concentrate the long-lived species, and other nuclear and solid-state parameters were favorable, it might be possible to convert sufficient population to the short-lived state to realize {gamma}-ray lasing. Even if the x-ray intensity were insufficient, study of such driven transitions would be quite valuable.
The effect that different chemical and physical atomic environments can have on the relative intensities of radiative electron transitions from the filling of K shell vacancies was investigated. The method used involved the detection of photoionization inducedX-ray fluorescence. An experimental system based on a hyper pure germanium detector (HPGE) was used to measure the relative K-L and K-M X-ray yields from the photofluorescence of a series of lanthanide elements and compounds. A background subtraction and peak integration strategy was employed which accounted for scattering in the samples and scattering of the flux from the radioisotope photoionization sources. Analysis of the data resulted in a tabulation of relative K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ratios. The measured relative K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ratios were compared to ...
The effect that different chemical and physical atomic environments can have on the relative intensities of radiative electron transitions from the filling of K shell vacancies was investigated. The method used involved the detection of photoionization inducedX-ray fluorescence. An experimental system based on a hyper pure germanium detector (HPGE) was used to measure the relative K-L and K-M X-ray yields from the photofluorescence of a series of lanthanide elements and compounds. A background subtraction and peak integration strategy was employed which accounted for scattering in the samples and scattering of the flux from the radioisotope photoionization sources. Analysis of the data resulted in a tabulation of relative K/sub #beta#//K/sub #alpha#/ X-ray intensity ratios. The measured relative K/sub #beta#//K/sub #alpha#/ X-ray intensity ratios were compared to the calculated ...
The measurements of the L X-ray intensity ratio I(L?)/I(L?), I(L?)/I(L?), I(L?)/I(L?), I(L?)/I(L?) and I(L?)/I(L?) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV ?-rays from a filtered radioisotope 241Am was used, and by the radioactive decay of 160Tb, 160Er, 173Lu, 182Re, 201Tl, 203Pb and 207Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L?/L?), I(L?/L?), I(L?/L?), I(L?/L?) and I(L?/L?) intensity ratios were calculated using theoretically tabulated values of subshell photoionization cross-section, fluorescence yield, fractional X-rayemission rates, Coster-Kronig transition probabilities. It was observed that present values agree with previous theoretical and other available ...
We report results from a 50 ks XMM-Newton observation of the dust-reddened broad-line quasar FTM 0830+3759 (z=0.413) selected from the FIRST/2MASS Red Quasar survey. For this AGN, a very short 9 ks Chandra exposure had suggested a feature-rich X-ray spectrum and HST images revealed a very disturbed host galaxy morphology. Contrary to classical, optically-selected quasars, the X-ray properties of red (i.e. with J-Ks> 1.7 and R-Ks> 4) broad line quasars are still quite unexplored, although there is a growing consensus that, due to moderate obscuration, these objects can offer a unique view of spectral components typically swamped by the AGN light in normal, blue quasars. The XMM-Newton observation discussed here has definitely confirmed the complexity of the X-ray spectrum revealing the presence of a cold (or mildly-ionized) absorber with Nh ~10^{22} cm^-2 along the line of sight to the nucleus and a Compton reflection ...
We report on the results of a simultaneous monitoring campaign employing eight Chandra X-ray (0.5-10 keV) and six VLA/EVLA (8.4 GHz) radio observations of NGC 4051 over seven months. Evidence for compact jets is observed in the 8.4 GHz radio band; This builds on mounting evidence that jet production may be prevalent even in radio-quiet Seyferts. Assuming comparatively negligible local diffuse emission in the nucleus, the results also demonstrate an inverse correlation of L_radio proportional to L_X-ray ^(-0.72+/-0.04) . Current research linking the mass of supermassive black holes and stellar-mass black holes in the "low/hard" state to X-ray luminosities and radio luminosities suggest a "fundamental plane of accretion onto black holes" that has a positive correlation of L_radio proportional to L_X-ray^(0.67+/-0.12) . Our simultaneous results differ from this relation by more than 11 ...
We have observed significant differences in the response to ionizing radiation of two closely related human cell lines, and now compare the effects on these lines of both low and intermediate LET radiation. Compared to TK6, WTK1 has an enhanced X-ray survival, and is also more resistant to cell killing by {alpha}-particles. The hprt locus is more mutable in WTK1 than in TK6 by both X-rays and {alpha}-particles. WTK1 is also more mutable by {alpha}-particles than by X-rays at the hprt locus. X-ray-induced mutation at the heterozygous tk locus in WTK1 is about 25 fold higher than in TK6, while {alpha}-particle-induced mutation is nearly 50 fold higher at this locus. Also, the slowly growing tk- mutants, which comprise the majority of spontaneous and X-ray-induced tk- mutants of TK6, were not induced significantly by {alpha}-particles. ...
We present a forward modelling technique for calculating the surface X-ray spectra for a variety of lunar terrains. Our calculations considered variations in solar fluxes from solar quiescent condition to large flare activity (M1 flare), and expected elemental concentrations in the target, as well as yield, instrumental, and viewing geometry parameters for X-rayinduced fluorescence from the lunar surface. Additionally, we present estimates of anticipated XRF signals from prominent Ka lines observable by a collimated 14cm2 X-ray detector from a 100km lunar orbit with 20km spatial resolution. Our results show that Mg, Al and Si characteristic Ka lines can be observed for all solar conditions. The Ca Ka lines line can be differentiated from a fixed background during more energetic solar cond...
Cluster calculations of the electronic structure and charge distribution in V_3Si have been performed using two different molecular orbital methods: a semiempirical LCAO and the MS X#alpha# model. The results are compared with X-rayemission spectra and band structure calculations. An analysis of the calculated electronic distribution reveals a charge transfer from Si-atoms to V-atoms, the additional charge on a V-atom being 0.6e (LCAO) and 0.4e (MS X#alpha# method). The results are in good agreement with experiment, which indicates that the cluster approach is adequate for the description of charge distributions and spectra characteristics of the A-15 compounds. (author).
From self-consistent band structure calculations using the 'augmented plane wave'(APW) method, the density of states can be decomposed into local partial (according to azimuthal quantum number l) components, the l-character densities. Within the APW formalism the intensity of X-rayemission spectra is determined by radial transition probabilities and l-character densities of such valence states, which reside inside the same atomic sphere as the core vacancy and whose quantum number l differs by +-1 from the one corresponding to the core state. By taking into account lifetime broadening of the core and valence states and also the instrumental broadening the computed spectra (non-metal K-, vanadium K- and Lsub(III)-spectra) agree well with experiment. (orig.).
We use UV/optical and X-ray observations of 272 radio-quiet Type 1 active galactic nuclei and quasars to investigate the C IV Baldwin Effect (BEff). The UV/optical spectra are drawn from the Hubble Space Telescope, International Ultraviolet Explorer and Sloan Digital Sky Survey archives. The X-ray spectra are from the Chandra and XMM-Newton archives. We apply correlation and partial-correlation analyses to the equivalent widths (EWs), continuum monochromatic luminosities, and ?ox, which characterizes the relative X-ray to UV brightness. The EW of the C IV ?1549 emission line is correlated with both ?ox and luminosity. We find that by regressing l?(2500 A) with EW(C IV) and ?ox, we can obtain tighter correlations than by regressing l?(2500 A) with only EW(C IV). Both correlation and regression analyses imply that l?(2500 A) is not the only factor controlling the changes of EW(C IV); ?ox (or, ...
X-ray ablation of material from the first wall and other components of an ICF (Inertial Confinement Fusion) chamber is a major threat to the laser final optics. Material condensing on these optics after a shot may cause damage with subsequent laser shots. To ensure the successful operation of the ICF facility, removal rates must be predicted accurately. The goal for this dissertation is to develop an experimentally validated x-ray response model, with particular application to the National Ignition Facility (NIF). Accurate knowledge of the x-ray and debris emissions from ICF targets is a critical first step in the process of predicting the performance of the target chamber system. A number of 1-D numerical simulations of NIF targets have been run to characterize target output in terms of energy, angular distribution, spectrum, and pulse shape. Scaling of output characteristics with variations of both ...
Coded imaging techniques using thick, micro-Fresnel zone plates as coded apertures have been used to image x-rayemissions (2-20 keV) and 3.5 MeV Alpha particle emissions from laser driven micro-implosions. Image resolution in these experiments was 3-8 ..mu..m. Extension of this coded imaging capability to higher energy x-rays (approx. 100 keV) and more penetrating charged particles (e.g. approx. 15 MeV protons) requires the fabrication of very thick (50-200 ..mu..m), high aspect ratio (10:1), gold Fresnel zone plates with narrow linewidths (5-25 ..mu..m) for use as coded aperatures. A reactive ion etch technique in oxygen has been used to produce thick zone plate patterns in polymer films. The polymer patterns serve as electroplating molds for the subsequent fabrication of the free-standing gold zone plate structures.
Coded imaging techniques using thick, micro-Fresnel zone plates as coded apertures have been used to image x-rayemission (2--20 keV) and 3.5 MeV Alpha particle emissions from laser driven micro-implosions. Image resolution in these experiments was 3--8 ..mu..m. Extension of this coded imaging capability to higher energy xrays (approx.100 KeV) and more penetrating charged particles (e.g., approx.15 MeV protons) requires the fabrication of very thick (50--200 ..mu..m), high aspect ratio (10:1), gold Fresnel zone plates with narrow linewidths (5--25 ..mu..m) for use as coded apertures. A reactive ion etch technique in oxygen has been used to produce thick zone plate patterns in polymer films. The polymer patterns serve as electroplating molds for the subsequent fabrication of the free-standing gold zone plate structures.
This paper reports that grinding and polishing affected the orientation of 90[degrees] domains at the surface of lead zirconate titanate (PZT) ceramics. This was quantified by using changes in the intensity ratio of the (002) and (200) X-ray reflections. Grinding unpoled PZT with 600-grit SiC paper gave X-ray intensity ratios similar to those of poled material. This implies that 90[degrees] domain realignments had occurred in the near surface region probed by the X-rays. Grinding poled samples with 600-grit SiC further increased the X-ray intensity ratio beyond that caused by poling, indicating that additional surface reorientation of 90[degrees] domains had occurred. The effects of diamond polishing depended on the size of the diamond particles. The use of 6-[mu]m diamond had no effect on the (002)/(200) intensity ratio of either poled or unpoled samples, while polishing with 15- or 45-[mu]m diamond ...
This paper reports that grinding and polishing affected the orientation of 90 degrees domains at the surface of lead zirconate titanate (PZT) ceramics. This was quantified by using changes in the intensity ratio of the (002) and (200) X-ray reflections. Grinding unpoled PZT with 600-grit SiC paper gave X-ray intensity ratios similar to those of poled material. This implies that 90 degrees domain realignments had occurred in the near surface region probed by the X-rays. Grinding poled samples with 600-grit SiC further increased the X-ray intensity ratio beyond that caused by poling, indicating that additional surface reorientation of 90 degrees domains had occurred. The effects of diamond polishing depended on the size of the diamond particles. The use of 6-#mu#m diamond had no effect on the (002)/(200) intensity ratio of either poled or unpoled samples, while polishing with 15- or 45-#mu#m diamond ...
Abstract: The ability of melatonin as a potent antioxidant was used as a rationale for testing its antiapoptotic ability in normal cells. Recently, melatonin was shown to possess proapoptotic action by increasing reactive oxygen species in certain cancer cells. The modification of radiation-induced apoptosis by melatonin and the expression of apoptosis-associated upstream regulators were studied in normal mice splenocytes and Jurkat T leukemia cells. C57BL/6 mice were exposed to a single whole body X-ray radiation dose of 2 Gy with or without 250 mg/kg melatonin pretreatment. The Jurkat cells were divided into four groups of control, 1 mm melatonin alone, 4 Gy irradiation-only and melatonin pretreatment before irradiation. The highest level of apoptosis in the normal splenic white pulp was...
We aim to obtain a consistent description of non-thermal emissions from Abell 2256 and to give a prediction for a gamma-ray emission from this galaxy cluster. Assuming that a radio relic illuminates a localization of an ongoing merger, and that both radio and non-thermal part of hard X-rayemission are due to electron component of cosmic rays filling the relic, we derived from radio and hard X-ray properties of the relic in A2256 the magnetic field strength and number densities for relativistic electrons and protons. Due to the interpretation of the radio relic as a structure formed just where a shock front is, we discuss a gamma-ray emission at the cluster periphery. The estimated strength of the magnetic field in the relic is equal to 0.05 \\muG, while the amplitude of the electron number density varies from 3 x 10^{-4} to 3 x 10^{-5} cm^{-3} (respectively for ...
When high-purity copper (≥99.98%wt) is melted, held in its liquid state for a few hours with iterative thermal cycling, then allowed to resolidify, the ingot surface is found to have...Full Text Available
Collisional-Radiative numerical models are commonly used to design or interpret experiments in atomic physics of laser-created plasmas, including X-ray laser studies. We describe our new code containing several options: average ion, more or less detailed configurations. It consists of an atomic data base coupled to subroutines evaluating ionic populations and emission and absorption coefficients. Numerical results are given to illustrate the capabilities of the code and to compare different models and types of approximation.
In this work we report a study of the induced changes in structure and corrosion behavior of martensitic stainless steels nitrided by plasma immersion ion implantation (PI"3) at different previous heat treatments. The samples were characterized by x-ray diffraction and glancing angle x-ray diffraction, scanning electron microscopy, energy dispersive x-ray spectroscopy, and potentiodynamic measurements. Depending on the proportion of retained austenite in the unimplanted material, different phase transformations are obtained at lower and intermediate temperatures of nitrogen implantation. At higher temperatures, the great mobility of the chromium yields CrN segregations like spots in random distribution, and the #alpha#"'-martensite is degraded to#alpha#-Fe (ferrite). The nitrided layer thickness follows a fairly linear relationship with the temperature and a parabolic law with the process time. The ...
Pd/sub 2/Si layers produced by evaporation or sputtering onto silicon substrates were examined by high resolution electron microscopy, microdiffraction, X-ray, energy loss and Auger spectroscopy. The Si-Pd/sub 2/Si interfaces produced by evaporation were in all cases rougher and more polycrystalline than those produced by sputtering. X-ray microanalysis showed the predictable variation in palladium distribution across the interface but quantification did not produce the expected palladium-to-silicon ratios, primarily because of probe broadening and X-ray-induced fluorescence. Energy loss spectra showed plasmon energy shifts and changes in Si L edge shape due to bond formation with palladium. Auger data provided evidence for a small amount of oxygen at the Si-Pd/sub 2/Si interface. Electrical measurements of the ideality factor for Schottky barriers made from the materials produced higher values for the rougher ...
Rossi X-ray Timing Explorer (RXTE) observations of the bright supernova remnant Cas A have revealed a hard power law component above 10 keV in addition to two thermal components inferred from ASCA measurements of the many line centroids from low-Z elements. The power law can be shown to be consistent with synchrotron emission from radio to hard x-rays by electrons of up to 4 x 10"1"3 eV. Measurement of the 1157 keV line by CGRO from "4"4Sc in the chain of decay of "4"4Ti predicts that the two "4"4Ti lines at 68 and 78 keV should appear at the CGRO intensity. RXTE has placed upper limits on such lines that are marginally consistent with the CGRO measurement. Implications of these results on sites for cosmic ray acceleration and nucleosynthesis are discussed.
The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...
The LCLS, a Free-Electron Laser (FEL) designed for operation at a first harmonic energy of 300 eV ({lambda} {congruent} 40{Angstrom}) in the Self-Amplified Spontaneous Emission (SASE) regime, will utilize electron bunches compressed down to durations of <0.5ps, or lengths of <150 {mu}. It is natural to inquire whether coherent radiation of this (and longer) wavelength will constitute a significant component of the total coherent output of the FEL. In this paper a determination of a simple upper bound on the IR that can be generated by the compressed bunches is outlines. Under the assumed operating parameters of the LCLS undulator, it is shown that that IR component of the coherent output should be strongly dominated by the x-ray component.
Molecular cluster predictions for electronic energy levels, wave functions, momentum densities, and Compton profiles of VO and VO_2 are examined within the Hartree-Fock-Slater model. VO_6 clusters are treated in O/subh/, D_4/subh/, and D_2/subh/ symmetry to obtain quantitative relations between distortion parameters and level shifts and splittings. Effects of the crystal environment are taken into account by a potential field. Results for VO are consistent with the augmented plane-wave band calculation of Mattheiss and x-rayemission data; the VO_2 levels are in good agreement with x-ray photoelectron spectroscopy data. A sizable anisotropy is predicted for the Compton profile of VO and VO_2.
Microcapsules consisting of alginate and hyaluronic acid that can be decomposed by radiation are currently under development. In this study, the composition of the microcapsule material was optimized by changing the amounts of alginate and hyaluronic acid. Solutions of 0.025%, 0.05%, 0.1%, 0.2%, or 0.4% (wt./vol.) hyaluronic acid were mixed into a 0.2% alginate solution. To these mixtures, carboplatin (0.2 mmol) was added and the resulting material was used for the capsule preparation. The capsules were prepared by spraying the material into a CaCl{sub 2} solution (0.34 mol/l) using a microatomizer. These capsules were irradiated by a single dose of 2, 5, or 10 Gy {sup 60}Co {gamma}-ray radiation. Immediately after irradiation, the releasing of core content of microcapsule was determined, using a micro particle inducedX-rayemission (PIXE) camera. The average diameter of the microcapsules was 22.3 {+-} 3.3 {mu}m, and that ...
Genomic instability can be produced by ionising radiation, so-called radiation-induced genomic instability, and chemical mutagens. Radiation-induced genomic instability occurs in both germinal and somatic cells and also in the offspring of irradiated individuals, and it is characterised by genetic changes including chromosomal rearrangements. The majority of studies of trans-generational, radiation-induced genomic instability have been described in the male germ line, whereas the authors who have chosen the female as a model are scarce. The aim of this work is to find out the radiation-induced effects in the foetal offspring of X-ray-treated female rats and, at the same time, the possible impact of this radiation-induced genomic instability on the action of a chemical mutagen. In order to achieve both goals, the quantity and quality of chromosomal damage were ...
... The constancy of the X-ray intensity ratio for each element in Table 8 as the X-ray tube settings were changed shows the excellent compensating ...
Epidermal growth factor receptor (EGFR) gene alterations have been found in human lung cancers. However, there is no information on the factors inducing EGFR mutations. In rodents, K-ras mutations are frequently found in many lung carcinogenesis models, but hitherto, Egfr mutations have not been reported. Their presence was therefore investigated in representative lung carcinogenesis models with 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), N-nitrosobis(2-hydroxypropyl)amine (BHP), 2-amino-3,8-dimethylimidazo[4,5-f]quinoxaline (MelQx) and ethyl carbamate (urethane), as well as X-ray irradiation. With the chemical carcinogenesis models, no mutations were detected in Egfr, which is in clear contrast to the high rates observed in either codon 12 or 61 of K-ras (21/23 of the lung tumors induced with NNK, 4/5 with MelQx, 1/4 with urethane and 7/18 with BHP). However, in the X-ray-induced lung tumors, ...
The Ksub(#beta#)/Ksub(#alpha# 12) x-ray intensity ratio of the Si K spectrum was measured for proton impact on Si0_2 in the energy range 300-800 keV. An energy dependence of the intensity ratio was found and an explanation is given in terms of multiple ionisation. (author).
We compare the accretion flow onto the neutron star induced by Roche lobe overflow with that by the overflow from the Be disk, in a zero eccentricity, short period binary with the same mass transfer rate, performing three-dimensional Smoothed Particle Hydrodynamics simulations. We find that a persistent accretion disk is formed around the neutron star in both cases. The circularization radius of the material transferred via Roche lobe overflow is larger than that of the material transfered from the Be disk. Thus, the growth of the accretion disk in the former case becomes significantly slower than in the latter case. In both cases, the mass accretion rate is very small and varies little with orbital phase, which is consistent with the observed X-ray behaviour of Be/X-ray binaries with circular orbits (e.g. XTE J1543-568).
Counting characteristics of X-ray detectors fabricated from indium-doped, gallium-doped, and chlorine-doped CdTe have been investigated. The detectors fabricated from indium-doped and gallium-doped crystals showed radiation-induced polarization, namely, a progressive decrease of count rate with an increase of photon fluence in the high-photon-fluence region, while the detectors fabricated from chlorine-doped crystals did not. Results from current-voltage characteristics of the detectors indicated that the different counting characteristics of these detectors originated from the difference in internal electric fields in each detector.
Bremstrahlung Isochromat Spectroscopy (BIS). The XES spectra were collected using a Specs electron gun for the excitation and the XES 350 grating monochromator and channel plate system from Scienta as the photon detection. Spectra were collected in 'normal mode,' where the electron gun kinetic energy (KE) and the energy position of the center of the channel plate were both fixed and the energy distribution in the photon (hv) spectrum was derived from the intensities distributed across the channel plate detector in the energy dispersal direction. The polycrystalline Ce sample was oxidized by exposure to air at ambient pressures. After introduction to the ultra-high vacuum system, the oxidized sample was bombarded with Ar, to clean the topmost surface region and stabilize the surface and near surface regions. Although CeO{sub 2} would be the thermodynamically preferred composition in an oxygen rich environment, the combination of a vacuum environment and ion etching may ...
Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point source results in a phase contrast too narrow for detection with CR. In addition to phase contrast improving ...
Abstract Visible blue cathodoluminescence (CL), photoluminescence (PL), x-ray excited optical luminescence (XEOL) and electroluminescence (EL) via Zf free excitonic emission have been obtained from CuBr thin films deposited on glass, Cr coated glass, GaAs and Si substrates. In addition to the Zf emission several peaks corresponding to Cu+ emissions via 3d94s - d10 transitions were observed on the AC EL spectrum at 2.10, 2.7, 3.03, 3.07 and 3.80 eV. X-ray diffraction (XRD) measurements confirmed that the vacuum evaporated CuBr thin films grow preferentially with a (111) orientation irrespective of the substrate. While the AC voltage source was found to have no detrimental effects on CuBr thin films, cathodic deposition of Cu metal via electrolytic decomposition was observed under steady sta...
First-principles self-consistent band-structure calculations of potassium titanyl arsenate, KTiOAsO_4 (KTA), have been made using the full potential linearized augmented plane wave (FP-LAPW) method. Total and partial densities of states of the constituent atoms of KTA have been derived. The results obtained show that the valence band of KTA is dominated by contributions of the O 2p-like states, while the Ti 3d-like states are the main contributors into the conduction band of the compound. Additionally, the FP-LAPW calculations have revealed that potassium atoms are highly ionized in KTA. In the present work, the X-rayemission spectroscopy (XES) and X-ray photoelectron spectroscopy (XPS) methods were also employed to investigate experimentally the electronic structure of potassium titanyl arsenate. For the mentioned compound, the XES K Ll, Ti L#alpha#, As K#beta#_2 and O K#alpha# bands reflecting the valence K s-, Ti s,d-, ...
The constituent phases and associated deformed microstructure of the quenched Ti-xNb-(0.5-1.5) at.% Si alloy consisting of non-cytotoxicity elements, where x = 24-30 at.%, were investigated to provide pseudoelasticity for biomedical and sensor applications. Optical microscopy revealed that stress-induced martensitic transformation takes place during the deformation in the present alloys. It is confirmed from the X-ray diffraction results of the deformed specimens that the crystal structure of the stress-induced martensite phase is the orthorhombic so-called #alpha#'' structure. Within the alloys having #beta#(bcc) phase studied Nb-poor region appeared to exhibit a dominant behavior for stress-induced martensitic transformation than Nb-rich region. This result suggests that metastable #beta# phase is superior to stable #beta# phase for the occurrence of stress-induced martensitic ...
Since 1984 a number of studies have been performed to investigate residual contamination at the former atomic weapons test site at Maralinga in South Australia, and to aid in the rehabilitation of the area. The largest site of plutonium contamination at Maralinga results from twelve Vixen B trials conduced at Taranaki in 1960, 1961 and 1963. Plutonium was dispersed along four major plumes from these trials. Measurements of the ratios of activities of "2"3"9Pu and "2"4"0Pu to "2"4"1Am are presented for the plumes. These are identified with individual trials where possible. Some measurements have also been made of "2"3"5U activities. An examination of meteorological and health physics survey data suggests that the most extensive part of the north-west plume results from a single trial, viz. Vixen B2 round 5 of 1961. It appears that the level of contamination in this plume was augmented by rainout of material, and the extent of the plume was enhanced by the considerable wind speed at the ...
Proton inducedX-ray and {gamma}-ray emission (PIXE/PIGE) have been used to analyze major and trace elements in a suite of 140 core samples from around of the Jim`s Find South gold anomaly in the Tanami desert, located in heavily weathered terrain. Simultaneous analyses were obtained for 30 elements, ranging in atomic number from {sup 3}Li to {sup 90}Th. The method was chosen because of its speed and the wide range of determination, its flexibility, precision and low detection limits. The regolith powder samples were treated by hot aqua regia before making them into pills. The PIXE/PIGE data of the acid insoluble residue give three factor analysis clusters. The first cluster comprises the elements F, Al, K, V, Mn, Fe, Ga, Rb, W and Au and is essentially related to sericitic wallrock alteration. The second cluster consists of Ti, As, Y, Zr, and Nb and is largely related to resistant minerals. The third cluster consists of ...
X-ray magnetic circular dichroism (XMCD) was used to probe the existence of induced magnetic moments in yttrium iron garnet (YIG) films in which yttrium is partly substituted with lanthanum, lutetium or bismuth. Spin polarization of the 4d states of yttrium and of the 5d states of lanthanum or lutetium was clearly demonstrated. Angular momentum resolved d-DOS of yttrium and lanthanun was shown to be split by the crystal field, the two resolved substructures having opposite magnetic polarization. The existence of a weak orbital moment involving the 6p states of bismuth was definitely established with the detection of a small XMCD signal at the Bi M{sub 1}-edge. Difference spectra also enhanced the visibility of subtle changes in the Fe K-edge XMCD spectra of YIG and {l_brace}Y, Bi{r_brace}IG films. Weak natural X-ray linear dichroism signatures were systematically observed with all iron garnet films and with a bulk YIG ...
Radioactive particles as well as x irradiation from an external source has been used in the treatment of rheumatoid arthritis, osteoarthritis, and ankylosing spondylitis. In order to clarify effects of ionizing irradiation on synovial cells, radioactive gold ("1"9"8Au) and yttrium ("9"0Y) were added to fibroblast cultures derived from human synovial membranes. Other cultures were irradiated by a Picker x-ray machine. Fibroblast growth and hyaluronic acid production were measured. Radioactive gold and yttrium particles induced a significant increase of hyaluronic acid synthesis rate (pg/cell/day) and inhibited fibroblast growth. Fibroblasts continued to overproduce hyaluronic acid and to show growth inhibition 3 weeks after irradiation with radioactive gold. Hydrocortisone inhibited hyaluronic acid overproduction induced by radioactive gold. Overproduction of hyaluronic acid induced by the ...
We study the high-energy emission of the Galactic black hole candidate GX 339-4 using INTEGRAL/SPI and simultaneous RXTE/PCA data. By the end of January 2007, when it reached its peak luminosity in hard X-rays, the source was in a bright hard state. The SPI data from this period show a good signal to noise ratio, allowing a detailed study of the spectral energy distribution up to several hundred keV. As a main result, we report on the detection of a variable hard spectral feature (>150 keV) which represents a significant excess with respect to the cutoff power law shape of the spectrum. The SPI data suggest that the intensity of this feature is positively correlated with the 25 - 50 keV luminosity of the source and the associated variability time scale is shorter than 7 hours. The simultaneous PCA data, however, show no significant change in the spectral shape, indicating that the source is not undergoing a canonical state transition. We ...
Various compositions of Y(Ta,Nb)O4:Eu3+,Tb3+ with different Nb and activator concentrations have been investigated under UV and VUV excitation. Some compounds with very strong emission under VUV excitation were found. Such phosphors could be proposed as very good emissive materials for Displays and Lightings. The growing interest in luminescence spectroscopy of rare earth ions in the vacuum ultraviolet (VUV) and the visible (VIS) spectral range is due to industrial demands for new applications. YTaO4 and YNbO4 phosphors are a perspective class of efficient materials that are generally used in X-ray intensifying screens. These phosphors exhibit satisfying luminescence whenever excited by UV light, cathode radiation or Xray. However, to our knowledge, no work has been published on the VUV-excited luminescence for Eu3+ and Tb3+ double activated yttrium niobate and yttrium tantalate ...
Context. The I(15.01 A)/I(16.78 A) emission line intensity ratio in Fe XVII has been reported to deviate from its theoretical value in solar and stellar X-ray spectra. This is attributed to opacity in the 15.01 A line, leading to a reduction in its intensity, and was interpreted in terms of a geometry in which the emitters and absorbers are spatially distinct. Aims. We study the I(15.01 A)/I(16.78 A) intensity ratio for the active cool dwarf EV Lac, in both flare and quiescent spectra. Methods. The observations were obtained with the Reflection Grating Spectrometer on the XMM-Newton satellite. The emission measure distribution versus temperature reconstruction technique is used for our analysis. Results. We find that the 15.01 A line exhibits a significant enhancement in intensity over the optically thin value. To our knowledge, this is the first time that such an enhancement has been detected on such a sound statistical ...
A 19.1 metre wind turbine blade was subjected to static tests. The purpose of the test series was to verify the abilities of different types of sensors to detect damage in wind turbine blades. Prior to each of the static test-series an artificial damage was made on the blade. The damage made for each test-series was surveyed during each series by acoustic emission, fiber optic micro bend displacement transducers and strain gauges. The propagation of the damage was determined by use of ultra sonic and X-ray surveillance during stops in the test series. By use of acoustic emission it was possible to measure damage propagation before the propagation was of visible size. By use of fiber optic micro bend displacement transducers and strain gauges it was possible to measure minor damage propagation. By use of both ultra sonic, and X-ray NDT-equipment it were possible to determine the size of propagated ...
Positron emission tomography (PET) and X-ray computed tomography (CT) performed with PET/CT cameras allow us to obtain concurrently information on the presence and degree of alterations of myocardial perfusion and metabolism and on coronary arteries calcification. Furthermore, by gated myocardial perfusion studies, PET may provide crucial information on regional coronary blood flow reserve and endothelial dysfunction. A number of recent papers provide some insight on the potential of PET/CT in cardiology and in the assessment of various cardiovascular diseases including various types of vasculitis and metabolic diseases.
The signature of the negative snakes from the soft X-ray cameras is very similar to the more usual snakes except that the localised region of the snake has, compared with its surroundings, decreased rather than increased emission. Circumstances where negative snakes have been seen are reviewed. The negative snake appears as a region of increased resistance and of increased impurity density. The relationship between the shear and the current perturbation is shown, and it seem probable that the magnetic shear is reversed at the point of the negative snake, i.e. that q is decreasing with radius. 6 refs., 6 figs.
Coherent x-ray production by a seeded free electron laser (FEL) is important for next generation synchrotron light sources. The authors examine the feasibility and features of FEL emission seeded by a high-order harmonic generation (HHG) of an infrared laser. In addition to the intrinsic FEL chirp, the longitudinal profile and spectral bandwidth of the HHG seed are modified significantly by the FEL interaction well before saturation. This smears out the original attosecond pulselet structure. The authors introduce criteria for this smearing effect on the pulselet and the stretching effect on the entire pulse. They discuss the noise issue in such a seeded FEL.
The measurements of the L X-ray intensity ratio I(L{alpha})/I(L{beta}), I(L{alpha})/I(L{gamma}), I(L{alpha})/I(L{iota}), I(L{beta})/I(L{gamma}) and I(L{iota})/I(L{gamma}) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a filtered radioisotope {sup 241}Am was used, and by the radioactive decay of {sup 160}Tb, {sup 160}Er, {sup 173}Lu, {sup 182}Re, {sup 201}Tl, {sup 203}Pb and {sup 207}Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L{alpha}/L{beta}), I(L{alpha}/L{gamma}), I(L{alpha}/L{iota}), I(L{beta}/L{gamma}) and I(L{iota}/L{gamma}) intensity ratios were calculated using theoretically tabulated values of subshell photoionization cross-section, fluorescence yield, fractional X-ray ...
A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. The authors established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging
Fuel irradiation leads to a swelling resulting from the formation of gaseous (Kr, Xe) or solid fission products which are found either in solution or as solid inclusions in the matrix. This phenomena has to be evaluated to be taken into account in fuel cladding Interaction. Fuel swelling was studied as a function of burn up by measuring the corresponding cell constant evolution by X-Ray diffraction. This study was realized on Mixed Oxide Fuels (MOX) irradiated in a Pressurized Water Reactor (PWR) at different burn-up for 3 initial Pu contents. Lattice parameter evolutions were followed as a function of burn-up for the irradiated fuel with and without an annealing thermal treatment. These experimental evolutions are compared to the theoretical evolutions calculated from the hard sphere model, using the fission product concentrations determined by the APPOLO computer code. Contribution of varying parameters influencing the unit cell value is discussed. Thermal ...
Depth resolved positron annihilation studies on Pd/Si thin film system have been carried out to investigate silicide phase formation and vacancy defect production induced by thermal annealing. The evolution of defect sensitive S-parameter clearly indicates the presence of divacancy defects across the interface, due to enhanced Si diffusion beyond 870 K consequent to silicide formation. Corroborative glancing incidence X-ray diffraction (GIXRD), Auger electron spectroscopy (AES) and Rutherford backscattering spectrometry (RBS) have elucidated the aspects related to silicide phase formation and Si surface segregation.
Glow discharge plasma nitriding of AISI 304 austenitic stainless steel has been carried out for different processing time under optimum discharge conditions established by spectroscopic analysis. The treated samples were analysed by X-ray diffraction (XRD) to explore the changes induced in the crystallographic structure. The XRD pattern confirmed the formation of an expanded austenite phase (#gamma#_N) owing to incorporation of nitrogen as an interstitial solid solution in the iron lattice. A Vickers microhardness tester was used to evaluate the surface hardness as a function of indentation depth (#mu#m). The results showed clear evidence of surface changes with substantial increase in surface hardness.
Argon ions irradiation of 12% Cr steels and Fe/Cr alloys results in the hardening up to 10000 MPa. This value exceeds the hardening level even for martensitic transformation. Along with the increase of microhardness following irradiation the shape of X-ray graph of the affected materials changes considerable. Hardening value and behavior are determined by temperature radiation doze, preliminary ageing, extent of cold strain and alloying. The odserved phenomenon is supposed to be caused by irradiation-induced structural transformations. Reversibility of radiation hardening of the materials in question was observed.
Longitudinal space charge (LSC) force can be a main effect driving the microbunching instability in the linac for an x-ray free-electron laser (FEL). In this paper, the LSC-induced beam modulation is studied using an integral equation approach that takes into account the transverse (radial) variation of LSC field for both the coasting beam limit and bunched beam. Changes of beam energy and the transverse beam size can be also incorporated. We discuss the validity of this approach and compare it with other analyses as well as numerical simulations.
Circularly polarized X-rays produced by a diamond X-ray phase retarder of thickness 0.5 mm in the Laue transmission configuration have been used for recording X-ray magnetic circular dichroism...Full Text Available
The radio, optical, x-ray and gamma-ray nebulae that surround many pulsars are thought to arise from synchrotron and inverse Compton emission. The energy powering this emission as well as the magnetic fields and relativistic particles are supplied by a 'wind' driven by the central object. The inner parts of the wind can be described using the equations of MHD, but these break down in the outer parts, when the density of charge carriers drops below a critical value. This paper reviews the wave properties of the inner part (striped wind), and uses a relativistic two-fluid model (cold electrons and positrons) to re-examine the nonlinear electromagnetic modes that propagate in the outer parts. It is shown that in a radial wind, two solutions exist for circularly polarized electromagnetic modes. At large distances one of them turns into a freely expanding flow containing a vacuum wave, whereas the other decelerates, ...
A detailed treatment is introduced to measure the dynamic stability of the relativistic electrons in a self-amplified spontaneous emission free-electron laser (FEL) system, which includes the numerical approach of the Kolmogorov entropy (entropy-like quantity), the general equations of motion for a charged particle and the method of monitoring the simulation accuracy. Numerical experiments reveal a new phenomenon that there exists the possibility of the transition from chaotic to non-chaotic phase-space trajectories of the strongly relativistic electrons due to the effect of their self-fields. The adiabatic magnetic field of a one-dimensional wiggler may have a slight influence on the electron transportation in the absence of the FEL fields, but substantially affects the dynamic stability of the electrons in the process of the FEL interaction. Moreover, the laser fields diminish the dynamic stability of the electrons as the FEL interaction grows exponentially.
The measurements of the K X-ray intensity ratio I(K{sub {beta}})/I(K{sub {alpha}}) for the 17 elements Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Br, Rb, Sr, Y, Zr, Nb and Mo have been done following ionization by 59.5keV {gamma}-rays from a {sup 241}Am point source. Ratios of emission probabilities of Auger electrons and the vacancy transfer coefficients have been extracted in terms of the intensity ratios. It is found that the present results agree well with earlier fitted values and the semi-empirical values.
Eu-#alpha#-SiAlON (Eu_m_/_2Si_1_2_-_m_-_nAl_m_+_nO_nN_1_6_-_n) was synthesized with nominal compositions having small m and n values, by firing the powder mixture of Eu_2Si_5N_8, #alpha#-Si_3N_4, AlN, and Al_2O_3 at 1900 "oC for 6 h under 1 MPa nitrogen atmosphere. The ratio of the oxidation state of Eu"2"+/Eu"3"+ was estimated from the X-ray absorption fine structure (XAFS) measurement. The observed X-ray absorption near edge spectrum (XANES) showed that the Eu ion in Eu-#alpha#-SiAlON was mainly in divalent state but also coexisted with a small amount of Eu in the trivalent state. The crystal structure of Eu-#alpha#-SiAlON was refined by the Rietveld analysis of the X-ray powder diffraction patterns. The lattice constants of the samples increased with increasing m and n values. The excitation band of Eu-#alpha#-SiAlON ranged from the ultraviolet to the visible light region and a broad emission band ...
We present a detailed spectral analysis of point-like X-ray sources in the XMM-COSMOS field. Our sample of 135 sources only includes those that have more than 100 net counts in the 0.3-10 keV energy band and have been identified through optical spectroscopy. The majority of the sources are well described by a simple power-law model with either no absorption (76%) or a significant intrinsic, absorbing column (20%).As expected, the distribution of intrinsic absorbing column densities is markedly different between AGN with or without broad optical emission lines. We find within our sample four Type-2 QSOs candidates (L_X > 10^44 erg/s, N_H > 10^22 cm^-2), with a spectral energy distribution well reproduced by a composite Seyfert-2 spectrum, that demonstrates the strength of the wide field XMM/COSMOS survey to detect these rare and underrepresented sources.
Radionuclide X-ray fluorescence analysis and fast neutron activation analysis were used for the determination of chromium. The excitation source for X-ray fluorescence analysis was a ring-shaped "2"4"1Am source with an activity of 18.5x10"9 Bq. SYNPOR filters of 35 mm in diameter were used for the measurement. The 5.414 keV Cr peak was measured with a Si(Li) detector. The sensitivity was 0.05 mg for a period of measurement of 1000 s. A neutron generator with an emission of 10"9 s"-"1 was used as the source of fast neutrons. "5"2V and "5"3V, the products of nuclear reaction with Cr, were measured gamma spectrometrically with a Ge(Li) detector. The sensitivity for Cr is 0.015 mg, in the presence of Mn which causes interference the sensitivity is a mere 0.075 mg. The mentioned methods were used to determine total Cr and Cr(VI) in welding aerosols. It was found that the most toxic form, i.e., Cr(VI), is released during manual ...
The X-ray spectra of {approx}200 AGN collected from Swift-BAT were analyzed to test the Unified Model for AGN. Specifically, the photon indices, high energy cutoffs, and reflection components of Sy1 and Sy2 were compared. Under the Unified Model, the photon indices and reflection components for Sy1 should be larger than Sy2 and the high energy cutoffs should be the same. Fitting a simple power law model to the sample spectra proved to be insufficient. The PEXRAV model fit the spectra of the Sy1 and Sy2 significantly better, indicating that a reflection component and/or high energy cutoff exists as the Unified Model expects. Using both the simple power law and PEXRAV models it was concluded that in the population studied, Sy1 had a larger photon index than Sy2, as expected by the Unified Model. For Sy1 and Sy2, the reflection components were found to be compatible, but given the large errors, this finding cannot be said to be evidence against the Unified Model. ...
The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial pilot studies with ...
The Westerbork Northern Sky Survey (WENSS) and the NRAO/VLA Sky Survey (NVSS) were used to determine an upper limit to the diffuse radio flux from the nearby cluster Abell 2199. For the entire cluster, this limit is <3.25 Jy at 327 MHz from WENSS; for the inner 15' radius, the limit is <168 mJy at 1.4 GHz. These limits are used to constrain the cluster magnetic field by requiring that the radio flux be consistent with the hard X-ray (HXR) flux observed by BeppoSAX, assuming that the observed HXR excess is due to inverse Compton (IC) scattering of cosmic microwave background photons by relativistic electrons in the intracluster gas. We find that the magnetic field must be very weak (<0.073 uG) in order to avoid producing an observable radio halo. We also consider the possibility that the HXR excess is due to nonthermal bremsstrahlung (NTB) by a population of suprathermal electrons which are being accelerated to higher energies. We find that a NTB model ...
Selective alveolo-bronchography (SAB) has been routinely used to evaluate anatomical changes in the bronchiole and its distal air spaces. A narrowing of the bronchiole and abnormal pooling of contrast medium in the destroyed air space are the prime findings. Since the object of radiography is extremely thin, direct magnification radiography is mandatory to obtain radiologic details. However, the problem with this technique is that radiographic quality varies depending upon the size of the patient and the concentration of contrast medium to be introduced in the lung. This study had two goals. One was to improve the image quality of SAB by Fuji Computed Radiography (FCR). FCR provides radiographs with a good contrast and stable density throughout a wide range of exposure factors which occur in the use of SAB. The other goal was to separately evaluate morphological abnormalities in the outer and inner zones of the lung using X-ray CT. This idea was derived from our ...
The shell integrity near peak compression of spherical implosions using the 60-beam, 30-kJ UV OMEGA laser system [Opt. Commun. 133, 495 (1997)] has been measured. Hot core emission backlights a shell with a thin titanium-doped layer that is imaged at x-ray photon energies above and below the titanium K edge. The x-ray intensity ratio between the two images is related to perturbations in the cold, or absorbing, part of the shell. The measured cold-shell areal-density modulations, integrated over the time of peak compression, are of the order of 25% to 50% with nonuniformity spectra peaked at spatial wavelengths of 30 to 50 #mu#m and with the smallest detectable nonuniformity features extending down to spatial wavelengths of 12 to 15 #mu#m. Hot-shell areal-density modulations of the emitting part of the shell (inner edge) are of the order of 13% to 20%. The measured shell modulations are in agreement with the results of ...
We describe a camera to record coherent scattering patterns with a soft-x-ray free-electron laser (FEL). The camera consists of a laterally graded multilayer mirror, which reflects the diffraction pattern onto a CCD detector. The mirror acts as a bandpass filter for both the wavelength and the angle, which isolates the desired scattering pattern from nonsample scattering or incoherent emission from the sample. The mirror also solves the particular problem of the extreme intensity of the FEL pulses, which are focused to greater than 10"1"4 W/cm"2. The strong undiffracted pulse passes through a hole in the mirror and propagates onto a beam dump at a distance behind the instrument rather than interacting with a beam stop placed near the CCD. The camera concept is extendable for the full range of the fundamental wavelength of the free electron laser in Hamburg (FLASH) FEL (i.e., between 6 and 60 nm) and into the water window. We have fabricated and ...
Monodisperse europium-activated titania hollow phosphors had been synthesized by a facile one-pot hydrothermal method using carbon spheres as hard templates. Samples were characterized by X-ray powder diffraction, transmission electron microscopy, X-ray photoelectron spectroscopy, energy dispersive spectrometer and photoluminescence spectrum. The strongest emission intensity was observed with TiO2:Eu0.2 hollow spheres and TiO2:Eu0.2 hollow spheres calcining at 550^oC. Moreover, the strongest excitation of TiO2:Eu0.2 hollow spheres transferred from 400 to 500^oC and the effective nonradiative energy transfer from the TiO2 hollow spheres host matrix to Eu^3^+ ions crystal field states was realized due to changes of crystalline field in the environment around Eu^3^+ ions occupying Ti^4^+ site...
X-rayemission spectroscopy (XES) and X-ray photoelectron spectroscopy (XPS) methods were employed in the present paper to investigate the electronic structure of face-centred cubic (fcc) molybdenum dioxide, fcc-MoO_2. For the mentioned compound, the XES O K#alpha# and Mo L#beta#_2_,_1_5 bands reflecting the valence O p- and Mo s,d-like states, respectively, were derived and compared on a common energy scale with the XPS valence-band spectrum. For comparison, the similar experimental studies of the electronic structure were made for a usual orthorhombic form of molybdenum trioxide, MoO_3. Band-structure calculations of fcc-MoO_2 were made using the full potential linearized augmented plane wave (FP-LAPW) method. A rather good agreement of the experimental XES and XPS results and the theoretical FP-LAPW data for the electronic properties of fcc-MoO_2 has been achieved in the present paper. A new near-Fermi sub-band was ...
The properties and kinetics of x-ray stars in globular clusters are described. Locations, configurations, star evolution, massive close binary systems, various mechanisms, and the x-ray burster properties are included. (JFP)
A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.
ASTROSAT, India's first dedicated astronomy satellite is slated for launch in 2007. The primary science objective of ASTROSAT is to explore the Universe using broad-band instruments covering optical, UV, soft X-ray and hard X-ray studies
The X-ray photoacoustic spectra of copper and brass (64.7 wt.% Cu and 35.3 wt.% Zn) have been measured at XANES (X-ray absorption near-edge structure) regions using synchrotron radiation. These spectra were compared with optical density of X-ray spectra. It is shown that the information derived from XANES is also included in the X-ray photoacoustic spectrum which reflects the heat production processes in copper and brass. However, the results showed that the increases and changes of the photoacoustic signal were different from those of the X-ray absorption coefficient at XANES regions. (author).
The results of a combined investigation of splat-quenched Fe-Csub(x) (x<0.05) alloys by resistivity, X-ray diffraction and Moessbauer spectroscopy are presented. The residual resistivity increases linearly with the carbon content (#DELTA#rho=5#mu##OMEGA#cm/at.%) with a slope identical to that observed in the dilute ferritic phase. X-ray diffraction reveals the presence of a martensite structure in addition to a small fraction of residual austenite; the dependence of the a and c lattice parameters on xsub(c) agrees with earlier measurements. A detailed investigation of the relative reflexion intensities shows that the as-quenched martensites consist of a mixing of massive martensite and tetragonal martensite for low carbon content and of tetragonal martensite only for xsub(c) approximately 0.05. The Moessbauer spectra reveal 3 or 4 magnetically non equivalent iron sites. From a detailed analysis of the intensity dependence of the subspectra ...
Structural variations in 39-MeV alpha-particle irradiated (Tsub(irr) = 60 deg C) polycrystalline molybdenum during post-irradiation annealing were studied by X-ray and TEM methods. Despite the high density of irradiation induced defects in the structure of the specimen X-ray measurements showed zero relative lattice parameter change after an irradiation dose of 1.1 x 10"-_2 dpa. However, during the annealing #delta#a/a was changed in the positive range, exhibiting two peaks - at 100 and 300 deg C - whereas the damage structure detected by TEM indicated no changes. Analysis of the results leads to the conclusion that in the range 100 to 250 deg C migration of isolated vacancies and their annihilation at interstitial clusters as well as possible formation of new vacancy clusters occur. The second peak on the #delta#a/a temperature dependence curve is related to the transformation (probably, thermal disintegration) of vacancy ...
Apoptosis, or programmed cell death (PCD), is a fundamental process that protects organismal integrity. In earlier work, we demonstrated that over-expression of either of two anti-apoptotic members of the BCL-2 family (BCL-2 or BCL-X L could elevate the frequency of radiation-induced mutations at the autosomal TK1 locus in human TK6 lymphoblasts that express wild-type TP53. Ectopic expression of BCL-X L also elevated the frequencies of double-strand break-induced gene conversion. The purpose of this study is to determine if BCL-2 family proteins promote radiation mutagenesis indirectly through their suppression of PCD, or whether the 'pro-mutagenic' function of these proteins can be separated from their anti-apoptotic function. We developed stable transfectants of TK6 cells that express a mutated form of BCL-X L with a single amino acid substitution in the BH1 domain that is known to interfere with the ability to suppress PCD (BCL-X L ...
In this study polycrystalline specimens of as-cast DyCu with B2 crystal structure were compressed to different strains at room temperature to test if stress-induced phase transformation and twinning occur during deformation. In these tests DyCu exhibited high ductility with plastic strain as high as 35% and ultimate compressive strength of ~790MPa. X-ray diffraction and transmission electron microscopy (TEM) showed no indications that DyCu had undergone stress-induced phase transformation or twinning. -type dislocations have been observed to play an important role for imparting the ductile behavior. TEM analyses showed the presence of second phases, Dy2O3 and DyCu2 within the DyCu. The mechanisms of ductility and impurity phase formation are discussed.
Pd-induced surface structures on Si(1 1 3) have been studied by scanning tunneling microscopy (STM) and X-ray photoelectron spectroscopy (XPS). In the initial process of the Pd adsorption below 0.10 ML, Pd silicide (Pd{sub 2}Si) clusters are observed to form randomly on the surface. By increasing the Pd coverage to 0.10 ML, the clusters cover the entire surface, and an amorphous layer is formed. After annealing the Si(1 1 3)-Pd surface at 600 deg. C, various types of islands and chain protrusions appears. The agglomeration, coalescence and crystallization of these islands are observed by using high temperature (HT-) STM. It is also found by XPS that the islands correspond to Pd{sub 2}Si structure. On the basis of these results, evolution of Pd-induced structures at high temperatures is in detail discussed.
One third of the microstructure of glassy carbon (GC) consists of closed pores. Density measurements indicate that the total pore volume depends only on the heat treatment temperature and not on the heat treatment time, a characteristic of coarsening. The kinetics of coarsening of these pores on heat treatment has been investigated by analyzing the changes in specific surface area of the pores as determined by the small angle X-ray scattering (SAXS) technique. A part of the surface area change is due to thermal expansion induced microcracking. Both the superposition method after correcting the thermal expansion induced surface area change and the curve fitting method give an activation energy of 64 +/- 10 kcal/mole. This value is compared with the activation energies of various rate processes in graphite. A model of coarsening of the pores based on a vacancy migration mechanism is proposed.
Maintenance of genomic integrity in embryonic cells is pivotal to proper embryogenesis, organogenesis and to the continuity of species. Cultured mouse embryonic stem cells (mESCs), a model for early embryonic cells, differ from cultured somatic cells in their capacity to remodel chromatin, in their repertoire of DNA repair enzymes, and in the regulation of cell cycle checkpoints. Using 129XC3HF1 mESCs heterozygous for Aprt, we characterized loss of Aprt heterozygosity after exposure to ionizing radiation. We report here that the frequency of loss of heterozygosity mutants in mESCs can be induced several hundred-fold by exposure to 5-10Gy of X-rays. This induction is 50-100-fold higher than the induction reported for mouse adult or embryonic fibroblasts. The primary mechanism underlying the...
Specimen damage and element loss induced by 3 MeV proton and 2 MeV alpha particle bombardment of thin sections of freeze-dried kidney tissue and embedding medium have been studied. Yields of ions scattered from H and C, and characteristic X-rays were measured versus accumulated charge, for curent densities in the range from 8x10{sup -15} to 1.1x10{sup -11} A/{mu}m{sup 2}. Structural damage, dissolouration and loss of S, Cl, C and H have been observed. Implications of this study for ion beam microanalysis of biological tissues are discussed with particular reference to the results for H loss. (orig.).
Ferrite of system, namely Ni_1_-_xZn_xFe_2O_4 with x = (0.0, 0.2, 0.4, 0.6, 0.8, 1.0), have been prepared by solid state reaction to investigate the effect of gamma rays irradiations using Co"6"0 source on the cation distribution, structural and magnetic properties. The unirradiated and irradiated samples were then subjected to characterization techniques such as X-ray diffraction, magnetization and AC susceptibility. The results of these characterizations are found to be different for irradiated from that of the pristine sample. The modifications in respect of irradiated samples are explained in terms of the ion-induced disorder. The important result of #gamma#-irradiation on the cation distribution, structural and magnetic properties is the change of ratio Fe"2"+/Fe"3"+. Possible reasons on the results are proposed.
An historic Strontianite-type specimen from Strontian, Scotland, UK, was characterized to broaden our knowledge on luminescence properties of common carbonates. These fibrous aggregates are Strontianite (Sr{sub x}Ca{sub 1-x}CO{sub 3}) with circa 6% of CaO, interfacial water, hydrosilicate anions and substitutional divalent cations, e.g., Ca{sup 2+}, Mn{sup 2+}, Fe{sup 2+} in structural Sr{sup 2+} positions. The specimen was analyzed by X-ray Fluorescence Spectrometry (XRF), Environmental Scanning Electron Microscopy coupled with an Energy Dispersive X-ray Spectroscopy (ESEM-EDS) probe, Spatially-resolved Cathodoluminescence under the Scanning Electron Microscope (SEM-CL), Differential-Thermal Analyses (DTA), Thermogravimetry (TG), Thermoluminescence (TL), Radioluminescence (RL) and High Resolution Spectra Thermoluminescence (3DTL), to gain an overview of the spectral emissions, the defect linkages were modified by heating ...
Manganese model complexes, relevant to the oxygen-evolving complex (OEC) in photosynthesis, were studied with Mn K-edge X-ray absorption near-edge spectroscopy (XANES), Mn Kb X-rayemission spectroscopy (XES), and vibrational spectroscopy. A more detailed understanding was obtained of the influence of nuclearity, overall structure, oxidation state, and ligand environment of the Mn atoms on the spectra from these methods. This refined understanding is necessary for improving the interpretation of spectra of the OEC. Mn XANES and Kb XES were used to study a di-(mu)-oxo and a mono-(mu)-oxo di-nuclear Mn compound in the (III,III), (III,IV), and (IV,IV) oxidation states. XANES spectra show energy shifts of 0.8 - 2.2 eV for 1-electron oxidation-state changes and 0.4 - 1.8 eV for ligand-environment changes. The shifts observed for Mn XES spectra were approximately 0.21 eV for oxidation state-changes and only approximately 0.04 eV ...
The effect of resonance, observed in X-ray waveguide layered structures in a characteristic way influences the scattering properties of the films. It is well known that the resonant region in the reflectivity shows a series of minima, usually very deep and extremely narrow. The positions and depths of the minima depend only on X-ray waveguide and quasi X-ray waveguide film structural properties, on the X-ray wavelength and on the incident beam divergence. In the present work we propose and discuss the application of the X-ray waveguide and quasi X-ray waveguide film structures as a tools to experimental evaluation of some quantities related to X-ray reflectometric and diffractometric measurements, like the beam divergence, wavelength, or angular distance. Examples of application of X-ray waveguide as an excellent tool ...
A brain weight deficit of about 70 mg was induced at doses of approximately 75-mGy and a deficit of 60 mg was induced at 100 mGy. This confirms the effects projected and observed by Wanner and Edwards. Although the data do not demonstrate a clear dose-response relationship between the 75-mGy and 100-mGy groups, the data are statistically consistent with a dose-response effect because of the overlapping confidence intervals. The lack of a statistically significant observation is most likely related to the small difference in doses and the limited numbers of animals examined. There are several factors that can influence the brain weight of guinea pig pups, such as caging and housing conditions, the sex of the animal, and litter size. These should be taken into account for accurate analysis. Dam weight did not appear to have a significant effect. The confirmation of a micrencephalic effect inducedx ...
The development of leukemia and thyroid cancer is characterized by activation of the abl oncogene and ret oncogene, respectively. In order to clarify the relationship between these gene aberrations and radiation, the pro-myelogenous leukemia-derived cell line HL60 and the thyroid cancer-derived cell line 8505C, were irradiated in vitro with 100Gy of X-rays. RNA was then extracted from 10"8 cells of the respective cell lines and examined by the reverse transcription PCR method for rearrangements of abl and ret genes. Five kinds of positive bands were observed in the HL-60 cells irradiated with 100Gy of X-ray. Similarly, six positive bands were also observed in the 8505C cells irradiated with 100Gy. In vitro X-irradiation activation of oncogenes found in radiation induced cancers imply that gene rearrangement by X-rays is involved in the development of malignant tumors. Furthermore, in an experiment to ...
The TiO2 hollow microspheres were prepared by microwave-assisted solvothermal treatment without template. The morphology and the phase of TiO2 hollow microspheres were characterized by X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM), high resolution transmission electron microscopy (HR-TEM), and BET surface areas. The results show that the particles have hollow structures and the shell was covered by nanocrystals and have higher specific surface area. The possible formation mechanism of hollow TiO2 spherical structures has simply been proposed. The activity was evaluated by the photocatalytic degradation of methyl orange (MO). The results show that the particles having specific surface area show higher photocatalytic activity. It can be attribute to the doped ...
A novel difunctional acylhydrazone has been synthesized by the reaction of 5-methylisoxazole-4-carboyl hydrazine with benzaldehyde and characterized by X-ray crystallography and spectroscopy. The obtained results demonstrate the crystal belongs to triclinic, space group Formula Not Shown . Moreover, the spectroscopic properties were evaluated through density functional theory (DFT) and time-dependent density functional theory (TD DFT) calculations. The results reveal that UV-Vis absorption peaks at 194, 217.5 and 290.5nm are mainly attributed to (p, p)p*, partly (p, p)p* and partly pp*, and predominantly pp*, respectively, with intraligand charge-transfer transition (ILCT) character. The fluorescence emission peak at 485.96nm should be assigned to ILCT. In addition, the results of antibact...
We synthesized Fe3O4Gg nanocomposites through a combination of solvothermal, hydrothermal, and chemical redox reactions. Characterization of the resulting samples by X-ray diffraction, Fourier-transform infrared spectroscopy, field-emission scanning and transmission electron microscopy, and magnetic measurement is reported. Compared to Fe3O4g nanocomposites, the Fe3O4Gg nanocomposites showed enhanced antibacterial activity. The Fe3O4Gg nanocomposites were able to almost entirely prevent growth of Escherichia coli when the concentration of Ag nanoparticles was 10mg/mL. Antibacterial activity of the Fe3O4Gg nanocomposites was maintained for more than 40h at 37^oC. The intermediate carbon layer not only protects magnetic core, but also improves the dispersion and antibacterial activity of the...
Relativistic strongly magnetized winds outflowing from fast-rotating compact objects like millisecond pulsars with surface magnetic fields of $\\sim 10^{15}-10^{16}$ G are plausible sources of cosmological $\\gamma$-ray bursts. In such winds, there are at least three regions where extremely powerful X-ray and $\\gamma$-ray emission may be generated. The first radiating region is the wind photosphere that is at a distance of $\\sim 10^9$ cm from the compact object. The second radiating region is at a distance of $\\sim 10^{13}-10^{14}$ cm. In this region, the striped component of the wind field is transformed into large-amplitude electromagnetic waves. The third radiating region is at a distance of $\\sim 10^{16}-10^{17}$ cm, where deceleration of the wind due to its interaction with an ambient medium becomes important. Radiation from all these regions is considered.
In order to quantify the biomass burning emissions, the main atmospheric pollution source of tropical and subtropical regions, we carried out the analysis of ashes that are also formed during these fires. To this end, we developed analytical methods to characterize the composition of savannah grass burning ashes by using X-ray fluorescence for mineral elements and microanalysis for C, H, O and N. Samples used in this work have been collected during laboratory combustion experiments, with chemically well-defined natural savannah grasses from Ivory Coasts and South Africa. The reproducibility and efficiency of different developed procedures have been studies. The analytical relative precision is generally better than 5%. This development has allowed to establish, for the first time, the global mass balance of ashes resulting from savannah grass burning. (authors). 16 refs., 3 figs., 8 tabs.
To improve the friction and wear behavior of carbon fabric reinforced polymer composites (CFRP), nano-SiO2 was deposited on the fabric surface. The friction and wear behavior of the resulting composites were investigated on a model ring-on-block test rig. Experimental results revealed that fiber surface treatment contributed to largely improve the tribological properties of the CFRP composites. Scanning electron microscope (SEM) investigation showed that the worn surface of the surface modified CFRP composite was smoother under given load and sliding rate. Field emission scanning electron microscopy (FESEM), FTIR and X-ray photoelectron spectroscopy (XPS) studies of the carbon fiber surface showed that nanostructured Sio2 thin film can be obtained by SiO2 sols deposition, which improved th...
Since 1979, scientists and engineers at the Los Alamos National Laboratory have designed, constructed, and operated a radio-frequency (RF) linac free-electron laser (FEL) at wavelengths from 9 to 45 /mu/m. Coupled with success of other research centers investigating wavelengths from the visible to far-infrared, Los Alamos is now proposing a vacuum-ultraviolet and soft x-ray (referred to henceforth as extreme ultraviolet, (XUV)) FEL oscillator/Self-Amplified Spontaneous Emission amplifier with beam energies ranging from 100 MeV to 1 GeV. This paper will focus on the first milestone of the proposed Los Alamos XUV project, i.e., a 250-MeV linac with approximately 50 mA of average current, producing photons with wavelengths below 1000 /angstrom/. 3 refs., 3 figs.
In this study, a novel graphene nanosheets (GNSs) coated solid phase microextraction (SPME) fiber was prepared by immobilizing microwave synthesized GNSs on a stainless steel wire. Microwave synthesized GNSs were verified by X-ray diffraction, field emission-scanning electron microscopy (FE-SEM) and transmission electron microscope (TEM). GNS-SPME fiber was characterized using FE-SEM and the results showed the GNS coating was homogeneous, porous, and highly adherent to the surface of the stainless steel fiber. The performance and feasibility of the GNS-SPME fiber was evaluated under one-step microwave assisted (MA) headspace (HS) SPME followed by gas chromatography with electron capture detection for five organochlorine pesticides (OCPs) in aqueous samples. Parameters influencing the extra...
ZnO thin films were electrodeposited in aqueous solution on gilded p-type Si wafer substrates. Thermal treatments were carried out on different films in Ar atmosphere at different temperatures, between 200 and 600 {sup 0}C. Surface morphology studies using scanning electron microscopy and atomic force microscopy show a smooth surface for an annealing temperature of 400 {sup 0}C with a roughness mean square value of about 15 nm and a precipitation of ZnO microcrystals on the deposit surface at 600 {sup 0}C. X-ray diffraction experiments reveal a decrease in the c-parameter value from 5.223 to 5.206 A after treatment at 600 {sup 0}C, due to the removal of hydrogen from the film. Raman spectroscopy analyses show an improvement in the crystal quality of the film and a decrease in the compressive stress inside the deposit. Photoluminescence observations reveal an important change in the UV emission band after annealing at 200 {sup 0}C. A visible ...
X-ray irradiation-induced paramagnetic radicals in rare earth (Ln) ion-doped glaserite and Ln ion-doped langbeinite were studied by means of ESR technique, aiming at developing the highly sensitive sensor for an ESR dosimetry. The samples were prepared by two kinds of procedures as follows. In one process, the glaserite (K{sub 3}Na(SO{sub 4}){sub 2}) matrix or the langbeinite (K{sub 2}Mg{sub 2}(SO{sub 4}){sub 3}) matrix were synthesized by heating the mixture of K{sub 2}SO{sub 4} and Na{sub 2}SO{sub 4} or the mixture of K{sub 2}SO{sub 4} and MgSO{sub 4} at 1023 K for 1 hour in He flow. The matrices obtained were mixed well with a fixed amount of Ln{sub 2}(SO{sub 4}){sub 3} (Ln=La, Eu, Gd, Lu) powder and heated at 1023 K for 1 hour in He flow. In the other process, the homogeneous mixture of a fixed amount of K{sub 2}SO{sub 4}, Na{sub 2}SO{sub 4} and Ln{sub 2}(SO{sub 4}){sub 3} powders or a fixed amount of K{sub 2}SO{sub 4}, MgSO{sub 4} and ...
Monochromator stabilization (MOSTAB) is a feedback control system to stabilize an x-ray beam of synchrotron radiation. It applies a feedback voltage to a piezo electric transducer attached to a double-crystal monochromator. We developed MOSTAB modules and examined their performances using SPring-8 beamlines. The x-ray beam position stabilization using MOSTAB was realized simultaneously with the x-ray beam intensity stabilization. As an example of its application, we performed EXAFS measurement with MOSTAB. (author)
Global angular momentum balance suggests that the neutron stars in Be/X-ray binaries are not spinning in equilibrium. This requires an X-ray lifetime ''approx <'' 10"5 yr, and suggests that there are many 'dead' Be/X-ray binaries in the Galaxy. Some of these may be turned up as millisecond radio pulsars with Be star companions. (author).
X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging
X-ray scattering methods suitable for the investigation of the morphology and chemical composition of self-organized quantum dots and quantum wires are reviewed. Their application is demonstrated in experimental examples showing that a combination of small angle X-ray scattering with high-resolution X-ray diffraction can reveal both the shape and the chemical composition of the self-organized objects. (author)
We have used the SINFONI integral field spectrograph to map the near-infrared K-band emission lines of molecular and ionised hydrogen in the central regions of two cool core galaxy clusters, Abell 2597 and Sersic 159-03. Gas is detected out to 20 kpc from the nuclei of the brightest cluster galaxies and found to be distributed in clumps and filaments around it. The ionised and molecular gas phases trace each other closely in extent and dynamical state. Both gas phases show signs of interaction with the active nucleus. Within the nuclear regions the kinetic luminosity of this gas is found to be somewhat smaller than the current radio luminosity. Outside the nuclear region the gas has a low velocity dispersion and shows smooth velocity gradients. There is no strong correlation between the intensity of the molecular and ionised gas emission and either the radio or X-rayemission. The molecular gas in Abell ...
Previous work has shown the Orion Bar to be an interface between ionized and molecular gas, viewed roughly edge on, which is excited by the light from the Trapezium cluster. Much of the emission from any star-forming region will originate from such interfaces, so the Bar serves as a foundation test of any emission model. Here we combine X-ray, optical, IR and radio data sets to derive emission spectra along the transition from H+ to H0 to H2 regions. We then reproduce the spectra of these layers with a simulation that simultaneously accounts for the detailed microphysics of the gas, the grains, and molecules, especially H2 and CO. The magnetic field, observed to be the dominant pressure in another region of the Orion Nebula, is treated as a free parameter, along with the density of cosmic rays. Our model successfully accounts for the optical, IR and radio observations across the Bar by including a ...
We construct a sample of low-redshift Ly-alpha emission-line selected sources from GALEX grism spectroscopy of nine deep fields to study the role of Ly-alpha emission in galaxy populations with cosmic time. Our final sample consists of 122 (142) sources selected in the redshift interval z=0.195-0.44 (z=0.65-1.25) from the FUV (NUV) channel. We classify the Ly-alpha sources as AGNs if high-ionization emission lines are present in their UV spectra and as galaxies otherwise. These classifications are broadly supported by comparisons with X-ray and optical spectroscopic observations. We classify additional sources as AGNs using line widths for our Ly-alpha emitter (LAE) analysis. Defining the GALEX LAE sample in the same way as high-redshift LAE samples, we show that LAEs constitute only about 5% of NUV-continuum selected galaxies at z~0.3. We also show that they are less common at z~0.3 than they are at ...
The author's achievements in the title field are summarized and discussed. The following topics are dealt with: (i) principles of radionuclide X-ray fluorescence analysis; (ii) mathematical methods in X-ray fluorescence analysis; (iii) Ross differential filters; (iv) application of radionuclide X-ray fluorescence analysis in the coal industry (with emphasis on the determination of the ash content, sulfur content, and arsenic content of coal); and (v) evaluation of the X-ray fluorescence analyzer from the radiological safety point of view. (P.A.).
Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)
Discusses methods for determining ash content in coal using backscattering in X-ray fluorescence. The following aspects are evaluated: principle of ash content determination, energy sources, factors that influence measurement accuracy, reliability. Types of X-ray fluorescence analyzers developed in Czechoslovakia and manufactured in the Czech Republic are comparatively evaluated. Operation of the RPM 113.1 radionuclide X-ray fluorescence analyzer developed by the PAR company and used for measuring ash content in coal and coal calorific value is discussed. 7 refs.
CH Cygni is a symbiotic star consisting of an M giant and an accreting white dwarf, which is known to be a highly variable X-ray source with a complex, two-component, spectra. Here we report on two Suzaku observations of CH Cyg, taken in 2006 January and May, during which the system was seen to be in a soft X-ray bright, hard X-ray faint state. Based on the extraordinary strength of the 6.4 keV fluorescent Fe K-alpha line, we show that the hard X-rays observed with Suzaku are dominated by scattering.
Elevation of zinc protoporphyrin (ZPP) levels in the blood has served as an indicator of lead poisoning and iron deficiency anemia for many years. We have discovered that sublethal doses of whole body irradiation with x-rays also elevates ZPP 2-3-fold over normal levels. The ZPP level does not begin to increase until days 12-14 postirradiation and peaks between days 18 and 20 before returning to normal levels between days 28 and 35. Increasing the radiation dose delays the onset of the rise in ZPP, but does not affect the magnitude of the elevation. At lethal doses, ZPP elevation is not observed. Neither of the two previously described mechanisms that cause elevations of ZPP, namely iron deficiency and inhibition of ferrochelatase, are responsible for the radiation-induced elevation of ZPP. The elevation of ZPP appears to be correlated with the recovery of the hematopoietic system from radiation injury.
The presence of washed or unwashed cellophane alone or together with a bleomycin, mitomycin C or hydrochlorothiazide, ('Esidrex') showed no appreciable effect on survival of either unirradiated or irradiated conidia. Irradiation for a period of 20min reduced the survival of conidia to 20%. The growth of irradiated conidia in the presence of bleomycin, mitomycin C or Esidrex is associated with a 2- to 3-fold increase in the frequency of gene convertants, but was not accompanied by an increase in point mutants. When conidia were grown on cellophane but otherwise treated as before the frequency of gene convertants was increased 8-fold, but induction of point mutants was negligible. This effect was the same for irradiated and unirradiated conidia. The environment created by the cellophane in contract with the medium appears to affect the action of each of the three compounds synergistically. (author).
The first part of the study contains a literature compilation of more than 50 original publications reporting the radiation induced effects in 17 different high polymer materials and glass which are relevant in the manufacturing of medical devices or packing materials. The results collected demonstrate that high energy radiation, i.e. gamma- or X-rays, causes various physical and chemical alterations in high polymer materials. A detailed summary and discussion of the results of the original publications is not included in the present report, it will be presented in the second part of the study. Furthermore, the second part of the study will refer to the aspect of wholesomeness of irradiated medical devices or packing materials in a more general manner of representation. (orig.).
Localized beam-processed areas using chemical reactions induced by a 30 keV Ga"+ focused ion beam (FIB) with and without I_2 (etching) and (CH_3)_3CH_3C_5H_5Pt gases (Pt deposition) have been analyzed using a 300 keV Be"2"+ microprobe with a beam spot size of 50-80 nm. The analyzed results have been compared with energy dispersive X-ray (EDX) analysis using an electron beam. The EDX analysis only indicated incorporated impurities at high fluence such as Ga, Pt and C, while microprobe RBS analysis could detect residual iodine with low concentration which couldn't be detected by EDS analysis because of the lower sensitivity of the EDX analysis for heavy atoms.
Regularities of deformation-induced dissolution of a surface layer of iron oxides in matrixes of iron-based alloys with bcc and fcc lattices have been studied by the methods of M?ssbauer spectroscopy, transmission electron microscopy, and X-ray diffraction. A method of producing iron alloys strengthened by dispersed oxide nanoparticles and alloyed with elements possessing a high affinity to oxygen (titanium and yttrium) has been proposed, which implies a dynamic dissolution of a surface layer of iron oxides upon strong cold deformation and a precipitation of secondary yttrium and titanium nanooxides upon a subsequent high-temperature sintering of mechanically alloyed powders. There has been demonstrated a possibility of oxide strengthening of pure iron upon its interaction with air without...
The presence of washed or unwashed cellophane alone or together with a bleomycin, mitomycin C or hydrochlorothiazide, ('Esidrex') showed no appreciable effect on survival of either unirradiated or irradiated conidia. Irradiation for a period of 20min reduced the survival of conidia to 20%. The growth of irradiated conidia in the presence of bleomycin, mitomycin C or Esidrex is associated with a 2- to 3-fold increase in the frequency of gene convertants, but was not accompanied by an increase in point mutants. When conidia were grown on cellophane but otherwise treated as before the frequency of gene convertants was increased 8-fold, but induction of point mutants was negligible. This effect was the same for irradiated and unirradiated conidia. The environment created by the cellophane in contract with the medium appears to affect the action of each of the three compounds synergistically.
A microanalytical characterization of cast magnesium alloys of eutectic origin based on the Mg?Al?Ca ternary matrix system has been carried out in order to investigate the influence of alloying elements on their microstructure as well as microchemistry-processing-microstructural relations using structure-sensitive techniques of electron microscopy, mechanical spectroscopy (internal friction), X-ray diffractometry, and advanced microanalytical methods including electron probe compositional analysis. Following the data obtained here there is direct correlation of microstructure with creep properties of the new experimental magnesium alloys. The creep and heat-induced properties of the multicomponent magnesium alloys containing low range of inexpensive additions of titanium (0.07?0.2%) or str...
The emission of light charged particles from heavy fragments of uranium fission induced by 153-MeV protons is studied. The probability of their emission is 2.7 x 10{sup - 2} per fission event. It is found that these particles affect the distribution of angles of fragment divergence and the angular distribution of heavy fragments with respect to the primary-proton beam. Experimental results suggest that the preequilibrium emission of particles is correlated with fission. Two mechanisms of interaction between 153-MeV protons and uranium nuclei are considered. 13 refs., 10 figs., 1 tab.
Ramsar, a city in the northern Iran, has the highest level of natural background radiation in the world. It has been clearly shown that low doses of ionising radiation can induce resistance to subsequent higher exposures. This phenomenon is termed radioadaptive response. We have compared induction of cytogenetic radioadaptive response by High Natural Background Radiation (HNBR) in Ramsar and X-ray occupational exposure as conditioning doses in human peripheral blood lymphocytes. 30 healthy control individuals, living in Ramsar but in normal background radiation areas, 15 healthy individuals from Talesh Mahalleh, a region with extraordinary high level of background radiation, and 7 X-ray radiographers working in Ramsar hospital located in normal natural background ionising radiation area were evaluated. Peripheral blood samples were prepared and exposed to challenge dose of 0 and 2 Gy. Lymphocytes were scored using analysis ...
We have been investigating radiation-induced neoplastic transformants of C3H 10T1/2 mouse fibroblasts for evidence of heritable changes. C3H 10T1/2 cells were treated with 8 Gy Xrays. After approximately 8 weeks of culture, type II/III foci were isolated from the monolayer using cloning rings. Cell lines developed from these foci, and clones established from these cell lines, were examined for DNA content. The isolated focus-derived populations and derived clones often display aneuploidy and/or polyploidization. In one instance a clone (derived from a single cell) displayed multiple polyploidies. During passage the ploidy of many of the anomalous populations gradually reverted to the ploidy of the non-neoplastically transformed state. The morphological features associated with the neoplastic transformation event were nevertheless retained. The results demonstrate that exposure to radiation can induce, ...
Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a ...
We report the discovery of an active galactic nucleus (AGN) pair in the interacting galaxy system IRAS 20210+1121 at z = 0.056. An XMM-Newton observation reveals the presence of an obscured (N _H #approx# 5 x 10"2"3 cm"-"2), Seyfert-like (L _2_-_1_0_k_e_V = 4.7 x 10"4"2 erg s"-"1) nucleus in the northern galaxy, which lacks unambiguous optical AGN signatures. Our spectral analysis also provides strong evidence that the IR-luminous southern galaxy hosts a Type 2 quasar embedded in a bright starburst emission. In particular, the X-ray primary continuum from the nucleus appears totally depressed in the XMM-Newton band as expected in the case of a Compton-thick absorber, and only the emission produced by Compton scattering ('reflection') of the continuum from circumnuclear matter is seen. As such, IRAS 20210+1121 seems to provide an excellent opportunity to witness a key, early phase in the quasar evolution predicted by the ...
Y{sub 2-x}Tb{sub x}SiO{sub 5} and Y{sub 2-x}Eu{sub x}SiO{sub 5} nanophosphors with seven different kinds of silicate sources were synthesized by sol-gel method. The structures have been investigated to be composed of nanometer-size grains of 30-60 nm through X-ray diffraction (XRD) and scanning electron microscopy (SEM) was used to compare the different morphology of patterns from seven different silicon sources. The photoluminescence of Y{sub 2-x}Tb{sub x}SiO{sub 5} was investigated as a function of silicate sources and the results revealed that these nanometer materials showed the characteristic emission {sup 5}D{sub 4} {yields} {sup 7}F{sub J} (J 6, 5, 4, 3) of Tb ions. The characteristic emission {sup 5}D{sub 0} {yields} {sup 7}F{sub J} (J = 1, 2, 4) of Eu ions was also found in the materials of Y{sub 2-x}Eu{sub x}SiO{sub 5}.
The CaWO{sub 4}:Ln{sup 3+} SiO{sub 2} (Ln=Tb, Dy and Ho) nanoparticles were synthesized via a combustion process at 800 {sup o}C, using citric acid as chelating agent and fuel, ammonium nitrate as fuel, boric acid as flux material and silica as supports. The persistent phosphor nanoparticles were characterized by X-ray diffraction (XRD), reflectance UV-vis and fluorescence spectroscopy (PL) and transmission electron microscopy (TEM) techniques. XRD patterns indicated that crystalline calcium tungstate with scheelite structure was produced. The reflectance UV-vis spectra showed the broad absorption band of WO{sub 4}{sup 2-} groups and the PL spectra showed the WO{sub 4}{sup 2-} wide excitation band, broad emission band of WO{sub 4}{sup 2-} and characteristic emissions of Ln{sup 3+} ions. The average particle sizes were determined by TEM, which are about 50 nm.
The CaWO_4:Ln"3"+ SiO_2 (Ln=Tb, Dy and Ho) nanoparticles were synthesized via a combustion process at 800 "oC, using citric acid as chelating agent and fuel, ammonium nitrate as fuel, boric acid as flux material and silica as supports. The persistent phosphor nanoparticles were characterized by X-ray diffraction (XRD), reflectance UV-vis and fluorescence spectroscopy (PL) and transmission electron microscopy (TEM) techniques. XRD patterns indicated that crystalline calcium tungstate with scheelite structure was produced. The reflectance UV-vis spectra showed the broad absorption band of WO_4"2"- groups and the PL spectra showed the WO_4"2"- wide excitation band, broad emission band of WO_4"2"- and characteristic emissions of Ln"3"+ ions. The average particle sizes were determined by TEM, which are about 50 nm.
Abstract Lithium-indium oxide is one of the candidate materials as solid-state scintillators for solar neutrinos due to an inverse --decay of 115In to 115Sn. On the other hand, when doped with rare-earth ions such as Eu3+ or Sm3+, it becomes a promising phosphor material. In this report we present a simple solid-state procedure for preparation of LiInO2:Eu3+ powders. X-ray diffraction confirmed prod-uct in tetragonal structural form (space group: I41/amd) and no impurity phases were detected. Then, high resolution photoluminescence emission measurements were performed at room and low temperatures to find 5D0 - 7FJ. Emission kinetics from 5D0 level exhibited pure single exponential behavior with lifetime of about 1.5 ms. Maximum energy splitting of 7F1 manifold is recorded as a function of ...
We present a new Chandra observation of supernova remnant (SNR) G350.1-0.3. The high resolution X-ray data reveal previously unresolved filamentary structures and allow us to perform detailed spectroscopy in the diffuse regions of this SNR. Spectral analysis demonstrates that the region of brightest emission is dominated by hot, metal-rich ejecta while the ambient material along the perimeter of the ejecta region and throughout the remnant's western half is mostly low-temperature, shocked interstellar/circumstellar medium (ISM/CSM) with solar-type composition. The data reveal that the emission extends far to the west of the ejecta region and imply a lower limit of 6.6 pc on the diameter of the source (at a distance of 4.5 kpc). We show that G350.1-0.3 is likely in the free expansion (ejecta-dominated) stage and calculate an age of 600-1200 years. The derived relationship between the shock velocity and the electron/proton ...
Stem-boring insects and methyl jasmonate (MeJA) are thought to induce similar complex chemical and anatomical defenses in conifers. To compare insect- and MeJA-induced terpenoid responses, we analyzed...Full Text Available
IRAM 30m observations reveal that the deeply obscured IR-luminous galaxy NGC4418 has a rich molecular chemistry - including unusually luminous HC3N line emission. We furthermore detect: ortho-H2CO 2-1, 3-2; CN 1-0, 2-1; HCO+, 1-0. 3-2, HCN 3-2, HNC 1-0, 3-2 (and tentatively OCS 12-11). The HCN, HCO+, H2CO and CN line emission can be fitted to densities of n=5 x 10E4 - 10E5 cm-3 and gas temperatures Tk=80-150 K. Both HNC and HC3N are, however, significantly more excited than the other species which requires higher gas densities - or radiative excitation through e.g. mid-IR pumping. The HCN line intensity is fainter than that of HCO+ and HNC for the 3-2 transition, in contrast to previous findings for the 1-0 lines where the HCN emission is the most luminous. We tentatively suggest that the observed molecular line emission is consistent with a young starburst, where the emission can ...
After having discussed the peculiarities of children in X-ray diagnosis the application of the effective as well as the mean equivalent doses as to the determination of the radiation exposure in children is represented. In using computerized tomograms to determine position and extent of an organ the exposure by repeated X-raying was calculated referring to the entrance dose. Entrance dose measurements for all types of X-ray examination in hospitals and ascertainments of the frequency of radiograms in 20 X-ray departments were used to determine per capita and collective doses, resp., in several age groups. Alltogether, the per capita dose of children in the GDR amounts to 30% of that of adults. Conclusions were drawn as to taking measures to further reduction of radiation exposure: (1) Technical measures, such as positioning of patients, shielding of organs, quality assurance; (2) elaboration of ...
Interest in optics for hard X-ray broad-band application is growing. In this paper, we compare the hard X-ray (20-100 keV) reflectivity obtained with an energy-dispersive reflectometer, of a standard commercial gold thin-film with that of a 600 bilayer W/Si X-ray supermirror. The reflectivity of the multilayer is found to agree extraordinarily well with theory (assuming an interface roughness of 4.5 Angstrom), while the agreement for the gold film is less, The overall performance of the supermirror is superior to that of gold, extending the band of reflection at least a factor of 2.8 beyond that of the gold, Various other design options are discussed, and we conclude that continued interest in the X-ray supermirror for broad-band hard X-ray applications is warranted.
A number of diagnostic X-ray units in Poland were subjected to analysis. The air kerma on X-ray tables was measured for the X-ray parameters used routinely during lumbo-sacral spine radiography of standard adult patient. Measurements of air kerma were performed using TLD made of lithium-fluoride. The doses received by patients in different X-ray departments can differ more than two orders of magnitude (from 0.42 mGy up to 72.11 mGy), for the same X-ray examination. The dose can be significantly reduced if fluorescent screens made from components of rare earth are used. (author). 10 refs, 1 fig., 2 tabs.
Full text: Introduction. Children, especially premature infants and neonates, are at a much higher risk to obtain an Xrayinduced disturbance of life - particularly cancer. On the one hand this is due to their longer life expectancy and on the other hand it is due to their higher cell proliferation rate. The paediatric radiology unit of the Inselspital Bern recently installed some of the most advanced Xray equipment nowadays available. It is based on the two latest digital technologies: double read computed radiography (CR) and direct digital radiography (DR). Only the implementation of these digital radiography systems permits the digital acquisition and additionally the analysis of acquired data. The systematic analysis of large amounts of biometric data and exposition data is the basis for further dose reduction and a systematic quality control (QC). Patients are increasingly ...
This thesis is concerned with the crystallisation behaviour of polymers near to a free surface or a buried interface. The properties of polymers are expected to differ significantly near to an interface (either with air or another polymer), due to the contributions of (a) chain configurations induced at the interface, and (b) different mobilities between interfacial regions and the bulk of the sample. For a semi-crystalline polymer, properties such as the degree of crystallinity and the crystallisation kinetics may be enhanced near to a free surface. Grazing incidence x--ray diffraction (GIXD) is used to investigate such effects in poly(ethylene terphthalate) (PET), showing that a lower crystallisation temperature is obtained at the surface, and the crystallisation kinetics are faster at the surface for all temperatures. It is proposed that in thin films of PET, this surface-induced ordering provides nucleation sites for ...
Mesporous anatase-phase TiO(2) hollow spheres with high photocatalytic activity were prepared by hydrothermal treatment and self-transformation of amorphous TiO(2) solid spheres in an NH(4)F aqueous solution. The prepared samples were characterized by X-ray diffraction, scanning and transmission electron microscopy, X-ray photoelectron spectroscopy, N(2) adsorption-desorption isotherms and UV-vis absorption spectroscopy. The photocatalytic activity was evaluated by photocatalytic oxidation decomposition of acetone in air under UV irradiation. It is found that F(-) plays an essential role in the formation of TiO(2) hollow spheres. F(-) not only induces the hollowing of TiO(2) solid spheres, but also promotes the crystallization of anatase TiO(2) nanocrystals. A possible formation mechanism for the TiO(2) hollow spheres by localized Ostwald ripening or chemically induced self-transformation is proposed ...
Ion Beam Induced Luminescence (IBIL) and Ion Beam Induced Charge Collection (IBICC) have been applied in the study of the luminescence emission efficiency and investigation of the homogeneity of the luminescence emission in phosphors. The IBIL imaging was performed by using sharply focused ion beams or broad/partially-focused ion beams. The luminescence emission homogeneity in samples was examined to reveal possible distributed crystal-defects that may lead to the inhomogeneity of the luminescence emission in samples.The purpose of the study is to search for suitable luminescent thin films that have high homogeneity of luminescence emission, large IBIL efficiency under heavy ion excitation, and can be placed as a thin layer on the top of microelectronic devices to be analyzed with Ion Photon Emission Microscopy (IPEM). ...
TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. ...
Measurements of ion-induced electron emission have been performed with helium and argon ions with energies between 300 and 900 eV on W, W with 10% Ti, Al, Al with 1% Cu, Al with 1% Si, Si, and Be. This article describes many of the important surface characteristics that influence the ion-induced electron emission. For low-energy ions, the substrate material was found to be less important as the velocity of the incident ion decreased. In the case of incident Ar"+ the substrate material had a negligible effect on the emission for this energy range. The presence of an adsorbed layer enhanced emission in all cases. Heating the substrates resulted in oxidation of the surfaces and a subsequent increase in emission. The electron emission from aluminum samples with smaller grain sizes was higher than samples of identical ...
PurposeThe goal of this study was to clarify the dynamics of tumor oxygen (partial pressure of oxygen, pO2) in SCC VII murine tumors in mice after X-ray...Full Text Available
Microplanar beam radiation therapy has been proposed to treat brain tumors by using a series of rapid exposures to an array of parallel x-ray beams, each beam having uniform microscopic thickness and...Full Text Available
The disulfide-reduced form of bovine ribonuclease A (RNAse A), with the Cys thiols irreversibly blocked, was characterized by small-angle x-ray scattering (SAXS). To help resolve the conflicting...Full Text Available
Radionuclide X-ray fluorescence analysis was used for the determination of iron, calcium, potassium, copper, manganese and zinc in waste water from the production process of citric acid.
Radionuclide X-ray fluorescence analysis was used for the determination of iron, calcium, potassium, copper, manganese and zinc in waste water from the production process of citric acid. (author).
Exact anatomic knowledge about the location of the gonads and the application of corresponding measures of radiation protection are the preconditions for an efficient reduction of the danger of a possible genetic damage as a result of radiation exposition during X-ray examination of the hip joint of newborns. (VJ).
Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and...Full Text Available
An examination of the noise of polycrystalline silicon thin film transistors, in the context of flat panel x-ray imager development, is reported. The study was conducted in the spirit of exploring...Full Text Available
Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.
In this paper, we report a method of precise in situ x-ray scattering measurements on protein solutions using small stationary sample cells. Although reduction in the radiation damage...Full Text Available
An analytic model of magnetic torques applied to an accreting neutron star is employed to evaluate the magnetic dipole moments of x-ray pulsars. A new type of close binary system containing a neutron star is suggested.
Differential phase-contrast X-ray imaging has been performed in a Talbot-Lau configuration, where a multiline X-ray source was used instead of a combination of a hard-X-ray multiple slit and a normal focus X-ray generator. When the multiple slit is used, a high aspect ratio structure is needed and slit width should be below 10 ?m for its function. The fabrication and use of such a multislit can be omitted using the presented configuration. The multiline X-ray source was developed by making grooves on a tungsten rotating anode, which was irradiated by an electron beam to generate X-rays. An array of 10?m line sources with a pitch of 30?m was formed and combined with a 4.5 ?m pitch phase grating and a 5.3 ?m pitch amplitude grating to generate differential phase contrast. With a total exposure time of 40 s, a differential phase image depicting cartilages was ...
Experimental, relative intensities for the components of L X-ray were collected from literature, and atomic-number dependency of L#beta#/L#alpha# has been found. (author).
K_#beta#/ K_#alpha# x-ray intensity ratio of chromium were measured in different chromium compounds. The results show the variation of the intensity ratio as a function of the chemical environment around the metal ion. (author)
Bi-U mixed oxides were synthesized by two methods and characterized by X-ray diffraction and X-ray photoelectron spectroscopy. The samples were tested for the catalytic oxidation of carbon monoxide by oxygen. A stepwise redox mechanism consistent with the kinetic results is proposed. (orig.).
picture will download the highest resolution version available. M51: X-Rays from the Whirlpool Credit: A. Wilson (UMD) et al., CXC, NASA Explanation: Fresh from yesterday's...
Previous studies have shown that iterative in-line x-ray phase retrieval algorithms may have higher precision than direct retrieval algorithms. This communication compares three iterative phase...Full Text Available
Certain applications are described of radionuclide X-ray fluorescence analysis in the ore dressing industry, in the manufacture of building materials, in metallurgy, pharmacy, in the chemical, photographic and paper industries, in space exploration, in archeology and for measuring the thicknesses of thin layers of coatings. (ES).
Strain-induced crystallization of crosslinked natural rubber (NR) and its synthetic analogue, cis-1,4-polyisoprene (IR), both mixed with various amounts of stearic acid (SA), were investigated by time-resolved X-ray diffraction using a powerful synchrotron radiation source and simultaneous mechanical (tensile) measurement. No acceleration or retardation was observed on NR in spite of the increase of SA amount. Even the SA-free IR crystallized upon stretching, and the overall crystallization behavior of IR shifted to the larger strain ratio with increasing SA content. No difference due to the SA was detected in the deformation of crystal lattice by stress for both NR and IR. These results suggested that the extended network chains are effective for the initiation of crystallization upon stretching, while the role of SA is trivial. These behaviors are much different from their crystallization at low temperature by standing, where SA acts as a ...
Iron oxide films have been deposited on Si(100) substrates by chemical vapour deposition (CVD) of iron(III) tert-butoxide ([Fe(O "tBu)_3]_2) in the temperature range 350-450 deg. C. The precursor flux and substrate temperature were varied to control the phase composition, average grain size and film thickness. The nature of substrate and deposition temperature markedly influence the morphology and iron-oxygen stoichiometry in the CVD deposits. Phase transformations in iron oxide films were achieved through precise local and periodic heating of the films by interfering laser beams. The interaction of iron oxide films with short laser pulses (Nd:YAG, 355 nm) induced partial transformation of hematite (#alpha#-Fe_2O_3) to magnetite (Fe_3O_4) or magnetite to wuestite (Fe_1_-_xO), respectively. The phase characterization and morphology of the hematite and magnetite films were investigated before and after laser irradiation by X-ray diffractometry, ...
Polycrystalline silicon films have been grown from Si{sub 2}H{sub 6} by low-pressure chemical vapour deposition at 800 K and in situ laser annealing (LA) on amorphous silicon seed layers deposited on a metallic Ti/Pd/Ag multilayer. The crystalline volume fraction in the seed layer was controlled by thermal annealing. According to the metal-induced crystallization effect, the presence of the metal induces a lower-temperature crystallization of silicon in the seed layers. X-ray diffraction and scanning electron microscopy data show that the formation of palladium silicides in the seed layer drives the growth of wire-like columns which are found to change morphology depending on the seed layer microstructure and LA parameters. It is suggested that superficial palladium was found to affect also the growth rate by enhancing the Si{sub 2}H{sub 6} dissociation.
Polycrystalline silicon films have been grown from Si_2H_6 by low-pressure chemical vapour deposition at 800 K and in situ laser annealing (LA) on amorphous silicon seed layers deposited on a metallic Ti/Pd/Ag multilayer. The crystalline volume fraction in the seed layer was controlled by thermal annealing. According to the metal-induced crystallization effect, the presence of the metal induces a lower-temperature crystallization of silicon in the seed layers. X-ray diffraction and scanning electron microscopy data show that the formation of palladium silicides in the seed layer drives the growth of wire-like columns which are found to change morphology depending on the seed layer microstructure and LA parameters. It is suggested that superficial palladium was found to affect also the growth rate by enhancing the Si_2H_6 dissociation.
The effects of the plasma nitriding with the formation of compound nitride and diffusion zones and of the boronising with the different ion doses on hydrogen distribution and hydrogen induced deterioration of a surface layer were examined in the case of Armco iron. Electrochemical studies of hydrogen permeation rate, hydrogen vacuum extraction measurements, optical and scanning microscopy, X-ray diffraction and elastic recoil detection analysis (ERDA) were used. Accumulation of entering hydrogen within the various constituent zones of the modified layer inhibits the hydrogen transport into the metal and thus, decreases the mean hydrogen content in the deeper zones and in the core. Hydrogen accumulation within the compact nitride zone causes the expansion of the nitride lattice, nitride phase transformation and deterioration. The ion boronising enhances the hydrogen effects in the plasma nitrided layers. Therefore, modification of the surface ...
Eu 4f electronic structures of a temperature-induced valence transition system EuPd{sub 2}Si{sub 2} have been investigated by bulk-sensitive high-resolution photoemission spectroscopy at temperatures from 20 to 300 K. The bulk Eu{sup 2+} 4f component is definitely distinguished from two surface Eu{sup 2+} 4f components. The changes in the spectral intensity of the bulk Eu{sup 2+} and Eu{sup 3+} 4f configurations and in the energy separation between these states are observed in the temperature dependent photoemission spectra. These temperature dependences are related to the valence transition of EuPd{sub 2}Si{sub 2}. The Eu mean valence is evaluated to be 2.75{+-}0.03 at 20 K and 2.30{+-}0.05 at 300 K. These values are in good agreement with those evaluated from Moessbauer and Eu L{sub III}-edge X-ray absorption measurements.
Currently, x-ray mammography is the method of choice in breast cancer screening programmes. As the mammography technology moves from 2D imaging modalities to 3D, conventional computational phantoms do not have sufficient detail to support the studies of these advanced imaging systems. Studies of these 3D imaging systems call for a realistic and sophisticated computational model of the breast. DeBRa (Detailed Breast model for Radiological studies) is the most advanced, detailed, 3D computational model of the breast developed recently for breast imaging studies. A DeBRa phantom can be constructed to model a compressed breast, as in film/screen, digital mammography and digital breast tomosynthesis studies, or a non-compressed breast as in positron emission mammography and breast CT studies. Both the cranial-caudal and mediolateral oblique views can be modelled. The anatomical details inside the phantom include the lactiferous duct system, the ...
We evaluated the similarities between ozone-induced and mite-inducedemission of volatile organic compounds (VOCs) from lima beans, and tested the response of the natural enemies of herbivores to these emissions using trophic system of two-spotted spider mites and predatory mites. The acute ozone-exposure and spider mite-infestation induced the emission of two homoterpenes, (E)-4,8-dimethyl-1,3,7-nonatriene and (E,E)-4,8,12-trimethyl-1,3,7,11-tridecatetraene, and (Z)-3-hexenyl acetate. Only plants with spider mite-infestation emitted the monoterpene (E)-{beta}-ocimene. Predatory mites were equally attracted to ozone-exposed and unexposed plants, but discriminated between spider mite-infested and uninfested plants, when both were exposed to ozone. The similarities between ozone and herbivore-induced VOCs suggest that plant defence against ...
The preparation by sputtering of artificial metallic superlattices is described, as are the results of x-ray structural determinations. Tunneling and resistivity measurements on these materials are reported.
An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds were studied by electron and proton bombardments. L{sub {gamma}1} X-rays which involve transition of 4d electrons of the valence shell were found to be sensitive to the chemical environment. The L{sub {gamma}1}/L{sub {beta}1} X-ray intensity ratio increased with an increase of the 4d electron occupation of niobium or molybdenum in niobium or molybdenum compounds, showing that the chemical effects can be ascribed to the 4d electron behavior of the metallic atom in its compounds. (orig.).
Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds were studied by electron and proton bombardments. L_#gamma#_1 X-rays which involve transition of 4d electrons of the valence shell were found to be sensitive to the chemical environment. The L_#gamma#_1/L_#beta#_1 X-ray intensity ratio increased with an increase of the 4d electron occupation of niobium or molybdenum in niobium or molybdenum compounds, showing that the chemical effects can be ascribed to the 4d electron behavior of the metallic atom in its compounds. (orig.).
There is a lot of interest in the studies that would help to understand whether there is a casual association between cancer and various types of molecular or cytogenetic damage detected in human cells. One major oncogenesis process is activation of proto-oncogenes by point mutations or chromosomal translocation. There are substantial evidence that indicates that the loss of heterozygosity of certain chromosomes is involved in human cancerogenesis. Our study aimed to elicit the possible association between cancer and DNA and cytogenetic abnormalities induced in lymphocytes of people bearing various categories of skin cancer cells. Fresh blood was collected by venipuncture from 25 individuals (including nine prior to cancer treatment). All patients were nonsmoking males, however 42.3 % of them were former smokers. Blood samples were divided into two parts and in the first part of samples cytogenetic studies were performed immediately, while from the second part ...
This case report evaluates X-ray findings in patients with miliary accumulation of mercury observed after parenteral application of metallic mercury in a suizide attempt. There are certain discrepancies between clinical symptoms and the X-ray findings. A clear demonstration of mercury in coronary blood vessels is possible by fluoroscopy.
These proceedings represent papers presented at the Astrophysics Conference in Maryland, USA. The topic of the Conference was the evolution of x-ray binaries and the papers encompass a wide range of subjects on x-ray astronomy. There were one hundred eighteen papers presented at the Conference and out of these three have been abstracted for the Energy Science and Technology database.
The physical foundations and methodology are described of radionuclide X-ray fluorescence analysis. The sources are listed of air, water and soil pollution, and the transfer of impurities into biological materials is described. A detailed description is presented of the sampling of air, soil and biological materials and their preparation for analysis. Greatest attention is devoted to radionuclide X-ray fluorescence analysis of the components of the environment. (ES).
The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.
Applications of X-ray fluorescence analysis in coal mining and geology are briefly described based on results published in Czechoslovakia as well as abroad over the past 3 years. Particular attention is paid to the rapid determination of the ash content of coal using portable radionuclide X-ray fluorescence analyzers that are being developed in Czechoslovakia. (author).
The achievement of inner-shell photoionization of Zn-like Pd by means of two exploding foils is described. This resulted in the soft X-ray transition 3d94s2-3d104p at 46 A. It is shown that the photoionization of inner shell electrons in highly stripped ions can lead to X-ray transitions which may be candidates for X-ray lasers under 50 A.
Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).
A brilliant Xray source is proposed for lithography instruments with use of a multi-mirror system. The inverse Compton scattering between the stored electron beam in the storage ring and the stored photon beam in the multi-mirror system, is applied for the X-ray generation. (author)
At the RIKEN-RAL Muon Facility, ?- to ? sticking K? X-rays were observed for the first time taking advantage of the pulsed beam structure. The precision of the present measurements was insufficient to distinguish between theoretical models, however the observed K?/K? X-ray intensity ratio tends to be smaller than most of these theoretical predictions.
Based on a literature study an actual summary of the risk-utility problems in X-ray diagnosis is outlined due to the Recommendations of the International Commission for Radiation Protection (ICRP publication 26/1977). Papers demonstrating quantitative assessment of the somatic and genetical risk in X-ray examination are preferably cited and evaluated. It is concluded that the somatic and genetical risk is low in diagnostic ratiology. However, it must not be neglected and has always to be compared to the utility of an examination as well as to other risks of the examination. (author).
In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).
The basic principles of determination of the ash content of coal by the title methods are outlined. A brief technical characteristic of the ash meters and radionuclide X-ray fluorescence analyzers manufactured by the PAR company is presented. (Z.S.). 4 figs., 7 refs.
Determination of Mn, Fe, Ni, Cu, Zn, and Pb in human soft tissues by radionuclide X-ray fluorescence analysis (using "2"3"8Pu and "1"0"9Cd sources) is described. The results of multielement XRS analysis of selected human tissues are tabulated. They are in good agreement with the literature data. It is concluded that X-ray fluorescence technique is a suitable method for trace element determination. (author).
The design of the first structural wall (FSW) in an inertial confinement fusion (ICF) reactor requires some knowledge of the expected wall loading produced by x-ray and neutron deposition; specifically in the High Yield Lithium Injection Fusion Energy (HYLIFE) reactor, wall loading results from two sources -- gas shock and liquid impact. Gas shock is derived from x-ray deposition in the thin layers of exposed blanket material, producing ionized vapor, which will generate gas shock on the FSW. Liquid impact, on the other hand, results from the acceleration of liquid blanket material by two possible forces -- the drag from vapor expansion through the blanket material and the neutron-induced isochoric disassembly process. Both impacts, however, are coupled by the interaction of hot gas expanding through the liquid blanket. This paper discusses scaling methods for estimating pressure and impulse on the HYLIFE FSW from these ...
The thickness dependent magnetic properties of artificially prepared ultrathin body-centered cubic Ni films have been explored using the all electron full potential linearized augmented plane wave (FLAPW) method. We have considered two types of BCC Ni(001) films: (i) pure BCC Ni(001) and (ii) Au capped BCC Ni(001) in the range from 1 monolayer (ML) to 4 ML of Au capping coverage. The average magnetic moment of pure BCC Ni(001) is about 0.63 #mu#_B and a typical surface enhancement is found with a magnetic moment of 0.78 #mu#_B. In the presence of an Au capping layer, the magnetic moment of interface Ni is strongly suppressed to approximately 0.5 #mu#_B and this causes a reduction of average magnetic moment. Nevertheless, the Au adlayer has no meaningful induced magnetic moment. The BCC pure Ni(001) films always have in-plane magnetization up to 11 ML, but very interestingly the Au/Ni(001) shows a thickness dependent spin reorientation transition (SRT) from in-plane ...
Using the full potential linearized augmented plane wave (FLAPW) method, the magnetic properties of two-dimensional Ru and Rh monolayers (MLs) on a NiAl(001) surface have been investigated. It has been found that free standing one monolayer Ru and Rh films have ferromagnetic ground state with magnetic moments of 2.21 and 1.48 #mu#_B, respectively. The ferromagnetism is still observed even on a Ni terminated NiAl(001) surface, while no magnetic state is found on an Al terminated surface. The calculated magnetic moments of Ru and Rh atoms are 1.56 and 0.88 #mu#_B, respectively. In addition, an induced magnetic moment in surface Ni is observed. It has been found that the free standing Ru film has perpendicular magnetization to the film surface with a magnetocrystalline anisotropy (MCA) energy of 0.66 meV/atom, while an in-plane MCA energy of 0.37 meV/atom is achieved in Rh film. Very interestingly, we find that both Ru/NiAl(001) and Rh/NiAl(001) films have ...
In this paper, we present the photoluminescence properties of Pr3+-, Sm3+- and Dy3+-doped germanate glasses and glass ceramics. From the X-ray diffraction measurement, the host glass structure was determined. These glasses have shown strong absorption bands in the near-infrared (NIR) region. Compared to Pr3+-, Sm3+- and Dy3+-doped glasses, their respective glass ceramics have shown stronger emissions due to the Ba2TiGe2O8 crystalline phase. For Pr3+-doped glass and glass ceramic, emission bands centered at 530nm (3P03H5), 614nm (3P03H6), 647nm (3P03F2) and 686nm (3P03F3) have been observed with 485nm (3H43P0) excitation wavelength. Of them, 647nm (3P03F2) has shown bright red emission. Emission bands of 4G5/26H5/2 (565nm), 4G5/26H7/2 (602nm) and 4G5/26H9/2 (648nm) for the Sm3+:glass and gl...
The X-ray diffraction (XRD) and environmental scanning electron microscopy (ESEM) analyses of plasters collected from the courtyard walls of Djehuty's tomb show anhydrite, calcite, dolomite, quartz, alkali feldspars and accessorial amounts of halite and illite. The external outer bed is mainly composed by anhydrite, since the original hydrous phases of gypsum plaster were desiccated during thirty centuries in the dry land environment of the Luxor area, under low relative humidity and high temperatures. The luminescence analyses by thermoluminescence (TL) and cathodoluminescence (CL) demonstrate as one plaster sample (m8), i.e., 95% anhydrite, displays a gigantic TL emission of 33 555 a.u. and a SEM/CL emission of 2319 a.u. maxima peak. The spectra CL also exhibits a 484 nm peak attributable to the classic {sup 4}F{sub 9/2}{yields}{sup 6}H{sub 15/2} transition circa 490 nm of Dy{sup 3+} and a 573 nm ...
Aims: To provide a significantly improved probability distribution for the H-test for periodicity in X-ray and $\\gamma$-ray arrival times, which is already extensively used by the $\\gamma$-ray pulsar community. Also, to obtain an analytical probability distribution for stacked test statistics in the case of a search for pulsed emission from an ensemble of pulsars where the significance per pulsar is relatively low, making individual detections insignificant on their own. This information is timely given the recent rapid discovery of new pulsars with the Fermi-LAT t $\\gamma$-ray telescope. Methods: Approximately $10^{14}$ realisations of the H-statistic ($H$) for random (white) noise is calculated from a random number generator for which the repitition cycle is $\\gg 10^{14}$. From these numbers the probability distribution $P(>H)$ is calculated. Results: The distribution of $H$ is is found to be exponential with parameter $\\lambda=0.4$ ...
Fine ceramic particles of zirconia toughened alumina (ZTA), titania toughened alumina (TTA), and zirconia-titania toughened alumina (ZTTA) have been synthesized by ultrasonic spray pyrolysis (USP) at various temperatures from starting salt solutions of various compositions aiming for the development of catalytic material. These particles were characterized for properties such as shape, size and size distribution, diffraction pattern, and chemical and phase composition of elements by scanning electron microscopy (SEM), particle size analyzer (PSA), x-ray diffraction (XRD), and inductively coupled plasma-atomic emission spectroscopy (ICP-AES). Chemical compositions and sizes of ceramic composites have been controlled by the stoichiometry of salt solutions and the flow rate of spraying solutions. The optimum experimental conditions for the various composite particle synthesis have been proposed.
Fine ceramic particles of zirconia toughened alumina (ZTA), titania toughened alumina (TTA), and zirconia-titania toughened alumina (ZTTA) have been synthesized by ultrasonic spray pyrolysis (USP) at various temperatures from starting salt solutions of various compositions aiming for the development of catalytic material. These particles were characterized for properties such as shape, size and size distribution, diffraction pattern, and chemical and phase composition of elements by scanning electron microscopy (SEM), particle size analyzer (PSA), x-ray diffraction (XRD), and inductively coupled plasma-atomic emission spectroscopy (ICP-AES). Chemical compositions and sizes of ceramic composites have been controlled by the stoichiometry of salt solutions and the flow rate of spraying solutions. The optimum experimental conditions for the various composite particle synthesis have been proposed.
Field emitter devices are being developed for the gigatron, a high-efficiency, high frequency and high power microwave source. One approach being investigated is porous silicon, where a dense matrix of nanoscopic pores are galvanically etched into a silicon surface. In the present paper pore morphologies were used to characterize these materials. Using of Scanning Electron Microscope (SEM) and Transmission Electron Microscope (TEM) images of both N-type and P-type porous layers, it is found that pores propagate along the <100> crystallographic direction, perpendicular to the surface of (100) silicon. Distinct morphologies were observed systematically near the surface, in the main bulk and near the bottom of N-type (100) silicon lift-off samples. It is seen that the pores are not cylindrical but exhibit more or less approximately square cross sections. X-ray diffraction spectra and electron diffraction patterns verified that bulk porous silicon is still a ...
The meeting was arranged into the following sessions: introductory; advanced ceramics and ceramic composites; ceramic and metal matrix composites; electronic materials and devices; acoustoelasticity, stress, and texture; composites-porosity, strength, and UT propagation; process modeling and monitoring; thermal wave physics; material properties, composites, surfaces, and interfaces; acoustic emission; ferromagnetic materials; new sensors; NDE reliability assessment; elastic wave scattering and propagation; image analysis, data storage, and signal processing; UT transducers; weldments and bonded materials; eddy current models; unified life cycle engineering; xrays, CT, and NMR; eddy current probes and instruments; acoustic microscopy imaging, and reconstruction; signal processing, measurement techniques, and systems; NDE applications of artificial intelligence; crack behavior influenced by history; inversion procedures for ...
We demonstrate that fitted values of stellar radius obtained by fitting theoretical light curves to observations of millisecond period X-ray pulsars can significantly depend on the method used to calculate the light curves. The worst-case errors in the fitted radius are evaluated by restricting ourselves to the case of light emitted and received in the equatorial plane of a rapidly-rotating neutron star. First, using an approximate flux which is adapted to the one-dimensional nature of such an emission region, we show how pulse shapes can be constructed using an exact spacetime metric and fully accounting for time-delay effects. We compare this to a method which approximates the exterior spacetime of the star by the Schwarzschild metric, inserts special relativistic effects by hand, and neglects time-delay effects. By comparing these methods, we show that there are significant differences in these methods for some applications, for example ...
Optically stimulated luminescence (OSL) and thermoluminescence are observed in polycrystalline RbMgF3:Eu2+ after x-ray, ?-ray, or ? irradiation. The main electron traps are F-centers but there are other unidentified traps. The main hole traps at room temperature are probably Eu3+ and thermal or optical stimulation leads to electron-hole recombination at the Eu3+ site and Eu2+ emissions arising from 6PJ to 8S7/2 and 4f5d(Eg) to 8S7/2 transitions. We find that some of the electron traps can be emptied by infrared stimulation and all of the electron traps can be emptied by white light stimulation. The OSL dark decay is long and exceeds 5 days for traps that are emptied by white light stimulation after initial infrared bleaching. Our results show that this compound can be used as a radiation dosimeter for intermediate dose levels where the 87Rb self-dose does not significantly affect the dose reading.
Photoluminescence properties and local electronic structures of rare earth (Eu^3^+ and Ce^3^+) activated Sr3AlO4F have been studied. X-ray powder diffraction data indicated that the activator ions of Eu^3^+ and Ce^3^+ can be incorporated into the Sr3AlO4F lattice and formed limited solid solutions of Sr3-2xLnxNaxAlO4F (Ln=Eu, Ce) with Na^+ as a charge compensator ion. The local structure around Sr sites was initially explored using Eu-activated Sr3AlO4F as a structural probe. Sr3AlO4F:Eu^3^+ exhibits orange-red emission ranging from 520 to 740nm with a maximum peak at about 619nm mainly originating from the ^5D0->^7FJ (J=0, 1, 2, 3, 4) transitions, indicating that Eu exists mainly in the trivalent state due to a strong oxidative lattice in Sr3AlO4F. Sr3AlO4F:Ce^3^+ shows an unusual long-wa...
We present the general properties of the far-ultraviolet (FUV; 1370-1720A) continuum background over most of the sky, obtained with the Spectroscopy of Plasma Evolution from Astrophysical Radiation instrument (SPEAR, also known as FIMS), flown aboard the STSAT-1 satellite mission. We find that the diffuse FUV continuum intensity is well correlated with N_{HI}, 100 $\\mu$m, and H-alpha intensities but anti-correlated with soft X-ray. The strongest correlation is with the H-alpha emission, and the correlation of the diffuse background with the direct stellar flux is weaker than the correlation with other parameters. The continuum spectra are relatively flat. However, a weak softening of the FUV spectra toward some sight lines, mostly at high Galactic latitudes, is found not only in direct-stellar but also in diffuse background spectra. The diffuse background is relatively softer that the direct stellar spectrum. We also find that the diffuse FUV ...
In a recent study of a search for enhancements from the galactic center with muons at sea level using the TUPI muon telescope, we have found several ground level enhancements (GLEs) as very sharp peaks above the count rate background. This paper reports a consistent analysis of two GLEs observed in December 2003 and detected after an up-grade of the data acquisition system, which includes a noise filter and which allows us to verify that the GLEs are not mere background fluctuations. The main target of this study is a search for the origin of the GLEs. The results show that one of them has a strong correlation with a solar flare, while the other has an unknown origin, because there is neither a satellite report of a solar flare, nor prompt X-rayemission, and nor a excess of nuclei during the raster scan where the GLE was observed. Even so, two possibilities are analyzed: the solar flare hypothesis and the gamma ray burst (GRB) hypothesis. We ...
The non-thermal supernova remnant RX J1713.7-3946 (G347.3-0.5) has recently been shown to be a site of cosmic ray (CR) electron acceleration to TeV energies (Muraishi et al. 2000). Here we present evidence that this remnant is also accelerating CR nuclei. Such nuclei can interact with ambient interstellar gas to produce high energy gamma-rays via the decay of neutral pions. We associate the unidentified EGRET GeV gamma- ray source 3EG J1714-3857 with a massive (~3*10 5 Mo) and dense (~500 nucleons cm -3) molecular cloud interacting with RX J1713.7-3946. Direct evidence for such interaction is provided by observations of the lowest two rotational transitions of CO in the cloud; as in other clear cases of interaction, the CO(J=2-1)/CO(J=1-0) ratio is significantly enhanced. Since the cloud is of low radio and X-ray brightness, CR electrons cannot be responsible for the bulk of its GeV emission there. A picture thus emerges where both electrons ...
Chromium electroplated AISI 316L stainless steel was nitrided using inductively coupled plasma (ICP) for application in the bipolar plate of a polymer electrolyte membrane fuel cell (PEMFC). A continuous and thin chromium nitride layer was formed at the surface of the samples after ICP nitriding for 2 h at 400 C. The interfacial contact resistance (ICR) and corrosion resistance in simulated PEMFC operating conditions were higher than the required values, while they varied with the applied dc bias voltage during the nitriding process. The ICR value decreased with an increase in bias voltage. Potentiodynamic polarization measurements showed that all of the nitrided samples had excellent corrosion resistance with a current density of {proportional_to}10{sup -7} A cm{sup -2} at the cathode. It was also found that the oxygen content at the surface was not increased after the corrosion test. X-ray diffractometry (XRD), field emission scanning ...
HD 100453 has an IR spectral energy distribution (SED) which can be fit with a power-law plus a blackbody. Previous analysis of the SED suggests that the system is a young Herbig Ae star with a gas-rich, flared disk. We reexamine the evolutionary state of the HD 100453 system by refining its age (based on a candidate low-mass companion) and by examining limits on the disk extent, mass accretion rate, and gas content of the disk environment. We confirm that HD 100453B is a common proper motion companion to HD 100453A, with a spectral type of M4.0V - M4.5V, and derive an age of 10 +/- 2 Myr. We find no evidence of mass accretion onto the star. Chandra ACIS-S imagery shows that the Herbig Ae star has L_X/L_Bol and an X-ray spectrum similar to non-accreting Beta Pic Moving Group early F stars. Moreover, the disk lacks the conspicuous Fe II emission and excess FUV continuum seen in spectra of actively accreting Herbig Ae stars, and from the FUV ...
We present results of near--IR long-slit spectroscopy in the J and K bands of the Seyfert 2 galaxies NGC 2110 and Circinus, investigating the gaseous distribution, excitation, reddening and kinematics. In NGC 2110, the emission line ratio [FeII]/Pa beta increases towards the nucleus (to ~ 7). The nuclear [Fe II]1.257 (microns) and Pa beta lines are broader (FWHM ~ 500 km/s) than the H2 (2.121) line (FWHM ~ 300 km/s). Both these results suggest that shocks, driven by the radio jet, are an important source of excitation of [Fe II]. The H2 excitation appears to be dominated by X-rays from the nucleus. In Circinus, both [FeII]/Pa beta and H2/Br gamma decrease from ~ 2 at 4 arcsec from the nucleus to nuclear values of ~ 0.6 and ~ 1, respectively, suggesting that the starburst dominates the nuclear excitation, while the AGN dominates the excitation further out (r > 2 arcsec). For both galaxies, the gaseous kinematics are consistent with circular ...
The fundamental optical properties of dysprosium (Dy) doped strontium sulfide bulk samples for various dopant concentrations from 0.1 to 1.0 at.% were investigated by X-ray diffraction (XRD), electron paramagnetic resonance spectroscopy (EPR), room temperature photoluminescence (PL), photoluminescence excitation (PLE) and diffuse reflectance spectroscopy (DRS). Investigations by electron paramagnetic resonance yielded the state of Dy in the sample as Dy3+. An additional ESR line due to F+ center was observed. The PL emission spectrum consisted of several intense lines and a number of weaker ones which were identified as transitions between energy levels of Dy3+. The optimum doping concentration for maximum intensity was found to be 0.25 at.%. Blue shift of the absorption edge energy and red shift of the PLE spectrum were observed with increasing doping concentration. The former is due to Burstein-Moss (BM) effect and the latter is attributed ...
A highly reliable screening method was developed for the determination of lead in tin plated layers and tin-bismuth plated layers. The contents of lead in the layers of the various samples were determined by inductively coupled plasma optical emission spectrometry. The calibration curve for lead in the tin and tin-bismuth plated layers by using WD-XRF exhibited linear correlation from 130 #mu#g/g to 2070 #mu#g/g. Calibration curve of lead normalized with Pb-L#alpha#/Sn-K#alpha# intensity was more linear, and this method was possible to evaluate very small sample. The calibration curve for lead in the tin plated layers by using ED-XRF was good linearly, but it for lead in the tin-bismuth plated layers was affected by Pb-L#alpha# spectrum and Bi-L#alpha# spectrum overlap each other. It was effective for decreasing affect of Bi-L#alpha# spectrum by using curve fitting method. (author)
To assess the diagnostic capability Fuji computed radiography (FCR) using a dual side reading system was compared to the conventional radiography using a film-screen system. Twenty-eight patients with lung cancer were examined with a new FCR system (FCR 5501D) and a conventional screen-film system concurrently. FCR utilizes a reading system that detects emissions from dual sides of imaging plate. Chest X-rays were obtained with same exposure factors in both systems. Image qualities of both systems were compared by two radiologists using a five-level score. There were no lesion that FCR images were inferior to film-screen images. The frequency of score +1 or +2 that FCR images were superior to film-screen images was 31% in large nodular shadows, 40% in accompanying shadows with a nodule, 67% of small nodular shadows, and 43% of the lymph node swelling in the hilum of the lung or mediastinum. In large nodular shadows which were the most frequent ...
A method has been developed to optimize the energy resolution of a horizontally focusing monochromator. The method consists of determining the optimum radius of curvature of the cylindrically bent monochromator crystal by minimizing the total diffracted X-ray flux measured through an X-ray absorption foil. When measured at an absorption edge a global minimum can be identified, which corresponds to the minimum energy band accepted along the entire length of the crystal. Experimental verification of this method has been validated by comparing X-ray fluorescent scans taken for a series of crystal curvatures and by directly measuring the X-ray beam profiles at the corresponding points. The actual optical configuration and asymmetric-cut parameter of the focusing monochromator on beamline X4C at the National Synchrotron Light Source are modeled and ray tracing simulations of the optical system are compared ...
Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of lifetime of the charge carriers with the increase of X-ray radiation dose.
An x-ray diffraction technique for determining thin-film thickness is presented which should prove to be a valuable alternative to the array of spectroscopies (Rutherford backscattering spectrometry, Auger electron spectroscopy, etc.) currently favored for these measurements. Some of the virtues of this x-ray diffraction approach are its nondestructive nature, fast data acquisition rate (enabling in situ observations), thickness resolution better than 5 nm, and conventional equipment requirements. Results are shown for Pd/sub 2/Si thin films grown during isothermal annealing of Pd coatings (100 nm) on Si at 200 /sup 0/C for various amounts of time. A comparison of these x-ray measurements with Rutherford backscattering spectrometry data taken from the same specimens is used to demonstrate the validity of the x-ray technique.
The {ital L}{sub 2}-{ital L}{sub 3} Coster-Kronig transition probability ({ital f}{sub 23}) in Tm was measured by multiparameter {ital K} versus {ital L} x-ray coincidence techniques. The Tm xrays were obtained from a radioactive source of {sup 169}Yb and were detected with cooled germanium and silicon detectors of high-energy resolution. Corrections were applied for the contribution of {ital K}{alpha}{sub 1} xrays to the {ital K}{alpha}{sub 2} x-ray peak and for the contribution of unresolved {ital L}{eta} xrays to the {ital L}{alpha}{sub 1,2} x-ray peak. The contribution of {ital K}{alpha}{sub 1} xrays to the {ital K}{alpha}{sub 2} x-ray peak was determined solely from the results of the coincidence measurements using a method of ...
The {ital L}{sub 2}-{ital L}{sub 3} Coster-Kronig transition probability ({ital f}{sub 23}) in Tm was measured by multiparameter {ital K} versus {ital L} x-ray coincidence techniques. The Tm xrays were obtained from a radioactive source of {sup 169}Yb and were detected with cooled germanium and silicon detectors of high-energy resolution. Corrections were applied for the contribution of {ital K}{alpha}{sub 1} xrays to the {ital K}{alpha}{sub 2} x-ray peak and for the contribution of unresolved {ital L}{eta} xrays to the {ital L}{alpha}{sub 1,2} x-ray peak. The contribution of {ital K}{alpha}{sub 1} xrays to the {ital K}{alpha}{sub 2} x-ray peak was determined solely from the results of the coincidence measurements using a method of ...
The interaction of intense, sub-picosecond laser pulses with solid targets produces intense picosecond x-ray pulses. With focused laser pulses of several 10 {sup 18} W/cm{sup 2}, He-like and H-like line radiation from targets such as aluminum and silicon has been produced. The energy conversion efficiency from the laser pulse energy to the 1--2 keV line x-rays is nearly one percent. The duration of the line x-ray radiation is of the order of ten picoseconds, although this may be an upper estimate because of the temporal resolution of the x-ray streak camera. The spatial extent of the x-ray source region is only slightly larger than the laser focal spot, or about 10 {mu}m in diameter. With these characteristics, such x-ray sources emit an intensity of nearly 10{sup 14} W/cm{sup 2}. Experiments and modeling which led to the above conclusions will be discussed.
A portable X-ray image system is described comprising: (a) a base assembly including panels and hinges joining the panels together along edges, and compression stops for biasing the hinges to compensate for the weight of payload when mounted on the base assembly, the compression stops being located for interaction with the hinges for biasing the panels to exhibit upward bowing when laid upon a flat surface prior to loading, and to provide resiliency for facilitating the base assembly assuming a substantially flat configuration when a predetermined payload is placed upon the base assembly; (b) an X-ray member; (c) apparatus for detachably mounting a table member to the base assembly to hold the table member at a location above the base; (d) an X-ray source; (e) means for sensing X-rays to form an image; (f) means for mounting the X-ray source and the X-ray ...
Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two detectors, respectively ...
We have studied the correlation between the chemical state and the oxygen-sensing properties of an iron oxide thin film using a setup that allows simultaneous sensor resistance measurements and X-ray photoelectron spectroscopy (XPS) data acquisition. The gas exposures were performed at the highest operating pressure of the XPS spectrometer at a controlled sample temperature which allows direct comparison between the sensor response and the chemical state of the surface. The iron oxide film was modified by a sequence of argon ion sputtering steps and the induced changes in the chemical state, resistance, and sensitivity to oxygen were investigated. The sputtering was found to reduce the iron from the Fe"3"+ to the Fe"2"+ state and to decrease the sensor resistance. The measured sensitivity to oxygen first increased by a factor of two but then collapsed to its original level. The mechanism for oxygen sensing was found to be filling of the oxygen ...
Free Electron Laser (FEL) with the wide wavelength tunability has been developed and used for various applications. The FEL gives high efficiency for the photo-induced ablation when the laser is tuned to an absorption maximum of the target. The FEL was tuned to 9.4 #mu#m, which is an absorption maximum of phosphoric acid ion, a known major component of dentine. The FEL pulse length was several ps. The average output power was varied from 5 to 20 mW by filters. The change of irradiated dentine surface was analyzed by mass spectroscopy and Energy Dispersive X-ray (EDX) spectroscopy. Positive ions which correspond to Na"+, CO_3"+ and many phosphoric acid ions were measured. It was found that atomic ratio of P/Ca had reduced from 0.65-0.60. The atomic ratio of P/Ca, however had not changed with irradiation by Er:YAG laser (2.9 #mu#m), or CO_2 laser (10.6 #mu#m). These results indicate the selective ablation of phosphoric acid ion by the 9.4 mm FEL ...
Performance of SRF cavities are limited by non-linear localized effects. The variation of local material characters between "hot" and "cold" spots is thus of intense interest. Such locations were identified in a BCP-etched large-grain single-cell cavity and removed for examination by high resolution electron microscopy (SEM), electron-back scattering diffraction microscopy (EBSD), optical microscopy, and 3D profilometry. Pits with clearly discernable crystal facets were observed in both "hotspot" and "coldspot" specimens. The pits were found in-grain, at bi-crystal boundaries, and on tri-crystal junctions. They are interpreted as etch pits induced by surface crystal defects (e.g. dislocations). All "coldspots" examined had qualitatively low density of etching pits or very shallow tri-crystal boundary junction. EBSD revealed the crystal structure surrounding the pits via crystal phase orientation mapping, while 3D profilometry gave information on the depth and size ...
Electron spin polarization in excess of 70% has been observed in photoemission from a 0.1 #mu#m-thick epitaxial layer of In_xGa_1_-_xAs with x #approx# 0.13 grown on a GaAs substrate. Under these conditions, the epitaxial layer is expected to be highly strained by the 0.9% lattice mismatch, as confirmed by x-ray diffractometer measurements of the lattice parameter. The electron polarization and the quantum efficiency have been measured as a function of the excitation photon energy from 1.25 to 2.0 eV. A significant enhancement of the electron polarization occurs in the vicinity of 1.33 eV where the expected strain-induced level splitting permits optical excitation of a single band transition. Measurements made on a control sample of 1.14 #mu#m thickness, significantly larger than the critical thickness for pseudomorphic strain, show no polarization enhancement. These measurements represent the first observation of strain-enhanced electron spin ...
Here we describe the use of low energy plasma immersion with active screen as a convenient approach for polypropylene (PP) surface modification. Employing a stainless steel cathodic cage coated with carbon in order to prevent the sputtering of iron from the grid and its deposition onto the polymer sample, the physical chemical properties of PP surface could be effectively modified through the plasma-induced incorporation/formation of nitrogen- and oxygen-containing species. The areal densities of these elements depended on the plasma excitation source, as determined by Rutherford backscattering spectrometry (RBS). Newly formed C-O, C-N, and C=O/O=C-O/N-C=O bonds along with C-C linkages from the PP backbone were identified at the near surface region of the specimens by X-ray photoelectron spectroscopy (XPS). The insertion of such polar reactive functionalities was further confirmed by a substantial decrease in the water contact angle upon plasma ...
Zinc molybdate (ZnMoO4) single crystals were grown for the first time by the Czochralski method and their luminescence was measured under Xray excitation in the temperature range 85-400 K. Properties of ZnMoO4 crystal as cryogenic low temperature scintillator were checked for the first time. Radioactive contamination of the ZnMoO4 crystal was estimated as <0.3 mBq/kg (228-Th) and 8 mBq/kg (226-Ra). Thanks to the simultaneous measurement of the scintillation light and the phonon signal, the alpha particles can be discriminated from the gamma/beta interactions, making this compound extremely promising for the search of neutrinoless Double Beta Decay of 100-Mo. We also report on the ability to discriminate the alpha-induced background without the light measurement, thanks to a different shape of the thermal signal that characterizes gamma/beta and alpha particle interactions.
The optical properties and microstructure of germanium (Ge) films, prepared by ion-assisted deposition (IAD) process, were investigated. The Ge films were deposited on sapphire and silicon substrates, with and without simultaneous Ar+ bombardment. Higher index films, with a refractive index 7.7% larger than that of the single crystalline Ge wafer, were obtained with the IAD process. The density of the IAD film could be 1.5% greater than that of the e-beam film. The results of the heat treatment indicated that the optical and structural properties of the IAD films were more stable. Ge nano-crystallites could be observed under high ion power density, which induced a crystalline structure in the Ge thin films. The average size of the nano-crystallites, as determined from both the X-ray diffraction data and the transmission electron microscopy images, showed that no systematic change had occurred. The results presented in this work suggest that the ...
Cross sections for excitation induced by electron collision between low-lying 1s{sup 2}2s{sup 2}2p{sup 5} and 1s{sup 2}2s2p{sup 6} states of f-like selenium and from these states to singly excited states with the excited electron occupying the M shell have been calculated by relativistic distorted-wave Born procedures. The GRASP{sup 2} code was used for the atomic structure calculations. The continuum orbitals for the construction of continuum states were computed in the distorted-wave approximation, in which the distorted-wave potential used was the spherically averaged potential of the nucleus plus the potential of the bound electrons of the bound state. The cross sections for excitations were computed first by a 233-level multiconfiguration Dirac-Fock (MCDF) configuration expansion and then by a 279-level MCDF configuration expansion. The latter procedure, which also took into account contributions from all the participating singly excited N-shell states, was ...
We report a study of the physical characteristics of the pillars of C, Pt and W grown by 10-30 keV Ga focused ion beam (FIB) as a function of Ga ion flux, and present a quantitative analysis of the elements using energy-dispersive analysis of X-rays (EDAX). All the FIB grown pillars exhibit a rough morphology with whisker like protrusions on the cylindrical surface and broadening of the base as compared to the nominal size. For a constant fluence, the height of the pillar initially increases and then reduces after going through a maximum as a function of ion flux in all the cases. The compositional analysis shows good metallic quality for Pt structures but reveals significant contamination of Ga in C and Ga and C in W structures at higher ion fluxes. Explanation to all these observations has been sought in the light of secondary ion and electron effects and the different processes involved which lead to the FIB induced deposition.
The interaction of the globular protein lysozyme with silica nanoparticles of diameter 20 nm was studied in a pH range between the isoelectric points (IEPs) of silica and the protein (pH 3-11). The adsorption affinity and capacity of lysozyme on the silica particles is increasing progressively with pH, and the adsorbed protein induces bridging aggregation of the silica particles. Structural properties of the aggregates were studied as a function of pH at a fixed protein-to-silica concentration ratio which corresponds to a surface concentration of protein well below a complete monolayer in the complete-binding regime at pH > 6. Sedimentation studies indicate the presence of compact aggregates at pH 4-6 and a loose flocculated network at pH 7-9, followed by a sharp decrease of aggregate size near the IEP of lysozyme. The structure of the bridged silica aggregates was studied by cryo-transmission electron microscopy (cryo-TEM) and small-angle ...
Radiation-induced enteritis is a well-recognized sequel of therapeutic irradiation. Therefore we examined the radioprotective properties of Punica granatum peel extract (PPE) on the oxidative damage in the ileum. Rats were exposed to a single whole-body X-ray irradiation of 800 cGy. Irradiated rats were pretreated orally with saline or PPE (50 mg/kg/day) for 10 days before irradiation and the following 10 days, while control rats received saline or PPE but no irradiation. Then plasma and ileum samples were obtained. Irradiation caused a decrease in glutathione and total antioxidant capacity, which was accompanied by increases in malondialdehyde levels, myeloperoxidase activity, collagen content of the tissue with a concomitant increase 8-hydroxy-2'-deoxyguanosine (an index of oxidative DNA damage). Similarly, pro-inflammatory cytokines (TNF-?, IL-1? and IL-6) and lactate dehydrogenase were elevated in irradiated groups as compared to control. ...
Full text: Measurement of K_#beta# to K_#alpha# x-ray intensity ratios are important not only in the field of atomic physics, radiation physics and medical physics, but also to test the validity of assumptions made in the theoretical prediction. The intensity ratios can also give information on the effect of physical and chemical environment of the element in the compound. Many investigators have adopted a single and double reflection geometries to measure the K_#beta# to K_#alpha# xray intensity ratios to understand the effect of physical and chemical environment on x-ray fluorescence. The targets are excited by a radioactive source of having activity of the order 100 MBq. in order to carry out accurate measurement K_#beta# to K_#alpha# x-ray intensity ratios, we have develop 2#pi# geometrical configuration method : placing a target right on the surface of the detector facing the ...
Proper assessment of the hypothesis which correlates polycyclic aromatic hydrocarbons (PAHs) with the unidentified infrared emission bands requires additional experimental laboratory data. In order to address this need, thermal infrared emission studies were performed on a subset of PAHs suggested to be of astrophysical importance. It was proposed that infrared emission from interstellar PAHs occurs following absorption of an ultraviolet photon. Since energy transfer to the ground electronic state can be rapid for a species in which intersystem crossing is negligible, the emission spectrum may be viewed as resulting from an equilibrium vibrational temperature (Leger and d'Hendecourt, 1987). This has been the basis for using infrared absorption spectra to calculate the corresponding emission spectra at various temperatures. These calculations were made using room temperature infrared ...
'Within 15 years the energy consumption bottleneck has shifted from the supply side to emissions, i.e. to the waste side.' Reflecting this statement one may realize the importance of lending more weight to energy conservation but may also be induced to critically analyze the corresponding measures. First results of such reflections are given with regard to the payback periods of air pollution abatement measures relative to the additional emissions they cause. (orig.).
It is shown that low-frequency elastic vibrations of near-surface planar defects cause high-frequency ultrasonic radiation in surrounding air. The frequency conversion mechanism is concerned with contact nonlinearity of the defect vibrations and provides efficient generation of air-coupled higher-order ultraharmonics, ultrasubharmonics, and combination frequencies. The nonlinear air-coupled ultrasonic emission is applied for location and high-resolution imaging of damage-induced defects in a variety of solid materials.
A large IMF- and event characterizing multidetector system (CHICSI) is under development for storage ring experiments. In ''test'' experiments with telescopes of CHICSI type the IMF production has been measured for "1"4N induced reactions at 14A and 32A MeV. Detailed information about the emission sources, particularly from the IMF yield in reactions with isotope separated targets and from isobaric yield ratios in the sub-Coulomb region is discussed. (orig.).
A finite three-dimensional layer-by-layer photonic crystal with planar defects in a layer is shown to drastically modify the spontaneous emission rate of an embedded dipole. Finite-difference time-domain calculations with one quarter symmetric boundary condition and perfectly matched layer demonstrate the strong enhancement effects induced by the cavity resonance of defect modes and band-edge resonant modes. Simulation shows that the emission spectra are quite different when the position or polarization of the dipole is changed. Moreover, the extraction efficiency is calculated to observe the percentage of light leakage through a substrate.
High-spatial-resolution microfocus-based X-ray imaging technology, both real-time and film, has been used to study the thickness variation that occurs in the oxide core of silver-sheathed BSCCO ribbons produced by the powder-in-tube method. This thickness variation (also called ``sausaging``) occurs during incremental rolling and degrades the critical current densities of the ribbons. Using X-ray image data the authors determined the onset and severity of sausaging. Onset occurred at a ribbon thickness of 203 {micro}m, and the severity increased with subsequent rolling reductions. Scanning electron microscopy was used to confirm the X-ray image data. X-ray imaging provides several advantages over more traditional methods for characterizing the superconductors such as optical or scanning electron microscopy. The X-ray imaging provides nondestructive information about the entire width ...
A convolution/superposition method is proposed for use with primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. It should be noted that the number of energy bins is usually about ten, and that the reconstructed X-ray spectra can reasonably be applied to media with a wide range of effective Z numbers, ranging from water to lead. The study was carried out for 10-MV X-ray doses in water and thorax-like phantoms with the use of open-jaw-collimated fields. The dose calculations were made separately for primary, scatter, and electron contamination dose components, for which we used two extended radiation sources: one was on the X-ray target and the other on the flattening filter. To calculate the in-air beam intensities at po...
The principle is described of X-ray fluorescence analysis and the manner of detecting the emitted characteristic radiation. The advantages are presented of radionuclide X-ray fluorescence analysis which consist primarily in the possibility of conducting a totally non-destructive analysis, and of accurate and relatively narrow localization of the analyzed area, the simultaneous qualitative and quantitative determinations of a large number of elements in the order of concentrations 10"1 to 10"-"4%, stability of excitation radiation flux, simple design and relatively low capital costs. The so-called matrix effect is pointed to. A number of examples is given of the use of the cited method, including its use in the analysis of art objects. (J.B.).
Some aspects of metrological provision of X-ray radiometric analyzers for mineral raw composition and gamma-gamma-logging equipment are considered. Standard samples (SS) based on the phenol-formaldehyde resin with the introduced quantities calculated of element compositions in the form of oxides and salts are described. Principles of metrological provision developed are used when carrying out state acceptance tests of X-ray radiometric analyzer RAL-M-102 ''Ehkran'' and gamma-gamma-logging equipmnt RSK-102. Economic benefit from introduction of an SS set is #approx# 60-100 thousand roubles per year.
The utilization of nuclear medicine bone scanning examinations early in the diagnostic process allows physicians to render prompt and correct treatment in urgent or difficult athletic cases. Bone scanning should be performed for athletic injuries whenever (1) x-rays are normal but bone or joint pain persists; (2) x-rays are positive but it cannot be determined if the findings are acute or chronic; (3) soft-tissue injuries present and x-rays are not useful; and (4) bone pain or joint impairment present without a history of trauma.89 references.
The textbook is primarily intended for radiologic staff and radiologic safety officers and gives information on the current regulatory provisions of the German X-ray Ordinance, applications of X-rays, quality assurance, organisational aspects of film processing and quality requirements of X-rays. An annex lists the guidelines of the Bundesaerztekammer (German National Chamber of Physicians) relating to quality assurance aspects, and further useful information on commercially available film-screen systems, the various associations of physicians in Germany, and requirements and performance of radiation surveys. (vhe).
Prior to routine use, all newly installed x-ray machines must have a radiation-protection survey by a qualified expert. The survey is an evaluation of existing or potential radiation hazards associated with the use of diagnostic x-ray equipment under specific conditions. Such evaluation includes the measurement of exposure levels in the environment as well as environmental levels arising from operation of the equipment. The survey also includes an evaluation of the safety characteristics of the x-ray unit.
Contributions to the population dose due to medical applications of ionising radiation are presented. It appears that contributions due to radiotherapy and Xray diagnosis are of comparable magnitude. To account for the age dependency of the radiation risks, contributions in terms of somatically significant dose equivalent are calculated as 0.3 mSv per caput per annum for Xray diagnosis and as 0.2 mSv per caput per annum for radiotherapy, the latter referring to only doses to organs outside the target volume. (author).
At the RIKEN-RAL Muon Facility, {mu}{sup -} to {alpha} sticking K{sub {beta}} X-rays were observed for the first time taking advantage of the pulsed beam structure. The precision of the present measurements was insufficient to distinguish between theoretical models, however the observed K{sub {beta}}/K{sub {alpha}} X-ray intensity ratio tends to be smaller than most of these theoretical predictions.
Total M X-ray cross sections for 12 elements in atomic range 70#<=#Z#<=#92 were measured at 5.96 keV Mn K X-ray photon energy. The average M shell fluorescence yields (anti #omega#_M) of these elements have also been observed using the presently measured cross section values and the theoretical M shell photoionisation cross section values. (orig.).
The L-subshell and total M-shell X-ray production cross sections of Ta, W, Pt, Au, Pb and Bi have been measured by protons of energy between 0.7 and 2.4 MeV. The obtained results for X-ray production cross sections have been compared with the existing experimental data, prediction of the ECPSSR theory and also with fitted empirical cross sections of Strivay and Weber.
A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.
The use of X-ray scattering techniques in pharmaceutical science is increasing, in part through increased collaborations with the materials science community, and through increased availability of instrumentation, particularly synchrotron sources. The ability to understand not only the biopharmaceutical outcome, but also arguably, more importantly, the structural aspects of drugs and drug delivery systems, is essential to progressing pharmaceutical science; this review serves as an introduction to the major techniques and the wide range of areas in which X-ray scattering may be applied in understanding and controlling structure in pharmaceutical systems.
Analytic expression is derived for X-ray fluorescence dependence on the particle size of powder and slurry media. The expression is obtained for a model of powder medium containing particles of different size and random distribution in the bulk of the sample. Limiting cases of homogeneous and slurry-like media are considered and expressions for calculation of the fluorescence intensity are derived. The results reasonably match the experiment for binary powder mixtures and thus provide evaluation of the powder particle size on the fluorescence intensity for multicomponent polydisperse powder medium
We have implemented a virtual Young's double slit experiment for hard X-ray photons with micro-fabricated bi-prisms. We observe fringe patterns with a scintillator, and quantify interferograms by detecting X-ray fluorescence from a scanned 30nm Cr metal film. The observed intensities are best modeled with a near-field, Fresnel analysis. The maximum fringe number in the overlap region is proportional to the ratio of real to imaginary parts refractive index of the prism material. The horizontal and vertical transverse coherence lengths at beamline APS 8-ID are measured.
The physical foundations are described of radionuclide X-ray fluorescence analysis (RXFA) and the table shows the values of K- and L-absorption thresholds and the K- and L-line energies of elements. The calculation of the intensity of characteristic radiation during RXFA proceeds from relations derived for conventional X-ray fluorescence analysis. The choice of the radionuclide source is ruled by the nature of the analysed substance and the used detection technique. The diagram shows the areas of radionuclide sources and the energy of the fluorescence radiation of elements. The table shows the spectra of radionuclide sources suitable for the purposes of RXFA measured by semiconductor Si(Li) and Ge(Li) detectors. (ES).
In scattering of channeled particles by point defects and in emission of gamma rays in the spontaneous-radiation spectral region conditions are attained where the momentum transferred to the defect is taken up by the crystal as a whole. This leads to coherent and interference effects in the radiation from the crystal defects. When the longitudinal momentum transferred is zero, an induced radiation effect appears in the transitions between the states of transverse motion.
Full text: The general population is daily exposed to chronic, low doses of ionizing radiation (IR) from both natural and artificial sources. The biological consequences of acute, high dose IR exposure can be readily determined; however, the nature and significance of low dose, low dose-rate IR effects are still the subject of debate. Confounding the issue, are the phenomena collectively referred to as the Radiation-induced Bystander Effect (RIBE). The RIBE describes a collection of in vitro observations that suggest the presence of a soluble, transmissible factor(s) released from irradiated cells that can induce a biological response in un-irradiated cells. The induction, nature and magnitude of the RIBE varies between cell culture systems, radiation sources and end-points measured. Efforts to confirm the presence of the RIBE in vivo have been confined to in vivo-like culture systems and limited work with tumour and bone-marrow transplantation ...
Research highlights: The dental implant of titanium could be modified by anodic oxidation. It was found that incorporation of strontium ions into the matrix increase the bone formation. In this study, we try to investigate the effect of corrosion property and bioactivity on coatings containing strontium by anodic oxidation. The results suggest that coatings containing strontium on titanium by anodic oxidation has the potential to show the stability and bioactivity in the clinical use. - Abstract: Pure titanium (Ti) and titanium alloys are considered as bio-inert materials in clinical use. Bioactivity is the ability to induce bone-like apatite on the material surface. The micro-arc oxidation (MAO) technique is an effective method for improving the surface properties of titanium. The aim of this study was to investigate the bioactivity and corrosion behavior of MAO coatings containing strontium, which is beneficial for biological performance. The bioactivity of ...
A significant amount of X-rays were detected as a leakage from some of the Crooke`s tubes which were used in the teaching of science at junior and senior high schools in Japan. We measured the leaked dose of X-rays from the Crooke`s tubes with ionizing chambers, film badges and TLDs. The maximum leaked dose at 5cm distance from those tubes was estimated 143mSv/h. The effective energy of leaked X-rays was 19.3keV. The maximum dose of students exposed during the teaching of science were estimated 0.15mSv per experiment, which exceeded the value recommended in the ICRP publication 36. (author)
The study aimed to determine the chemical effects on the K and L X-ray intensity ratios and the K and L X-ray production cross sections for gold compounds. The K shell fluorescence yields and L shell average yields were also investigated. The samples were excited by 59.5keV ?-rays from an 241Am annular radioactive source and 123.6keV ?-rays from a 57Co annular radioactive source. K and L X-rays emitted from samples were counted by an Ultra-LEGe detector with a resolution of 0.150keV at 5.9keV. The experimental values were compared with theoretical, the semi-empirical and other experimental values.
... Special Purpse Lead Azide Lot #I3A-4-62 ... Standard X-ray techniques are not sufficiently sensitive ... the National Bureau of Standards, and examined ...
Resonant inelastic x-ray scattering (RIXS) with soft x-rays is uniquely suited to study the elec-tronic structure of a variety of materials, but is currently limited by low (fluorescence yield) count rates. This limitation is overcome with a new high-transmission spectrometer that allows to measure soft x-ray RIXS"maps." The S L2,3 RIXS map of CdS is discussed and compared with density functional calculations. The map allows the extraction of decay channel-specific"absorp-tion spectra," giving detailed insight into the wave functions of occupied and unoccupied elec-tronic states.
Energy-filtered X-ray photoemission electron microscopy (EXPEEM) is a microscopy technique which has the potential to provide surface chemical mapping during surface chemical processes on the nanometer scale. We studied the possibilities of EXPEEM using a Wien filter type energy analyzer in the high energy X-ray region above 1000 eV. We have successfully observed the EXPEEM images of Au islands on a Ta sheet using Au 3d_5_/_2 and Ta 3d_5_/_2 photoelectron peaks which were excited by 2380 eV X-rays emitted from an undulator (BL2A) at Photon Factory. Our recent efforts to improve the sensitivity of the Wien filter energy analyzer will also be discussed.
Objective: To investigate the X-ray radiation dose patients dealt with the hepatic intervention. Methods: Thermoluminescence and tissue-equivalent anthropomorphic phantom were used to measure the X-ray radiation dose in patients dealt with the hepatic intervention in 85 patients. Results: The peak skin dose in the patients who accepted hepatic intervention was from 179.95 to 1759.00 mGy, effective dose approached 29.22 mSv (male), 29.27 mSv (female). Conclusion: Hepatic intervention is now regarded as an important therapeutic method for liver cancer. However, the patients were exposed to too much X-ray radiation during interventional procedures. Some more effective protection should be taken to decrease the X-ray radiation dose accepted by patients. (authors)
The time and dose characteristics of the electron and X-ray radiations of a tube, connected to a subnanosecond mega volt accelerator, are measured. By the pulse of the accelerating voltage of #>=# 600 kV with duration of #approx =# 0.3 ns the tube generates approximately 5 x 10"1"2 electrons pulse. The current amplitude equals approximately 5 kA/pulse and the radiation dose-about 5 kGy/pulse. The X-ray radiation dose from the tantalum external target constitutes 0.15 Gy/pulse. The prototypes of the electron and X-ray tubes sufficiently lower volumes, opening new applications in the technique and medicine, are developed
The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.
by the radionuclide X-ray fluorescence analysis into several groups according to the atomic number of the determined element. Table I documents this. ...
M-shell X-ray production cross sections for the light rare-earth elements of {sup 68}Er, {sup 7}Yb and {sup 71}Lu have been measured for incident {sup 4}He{sup +} ions in the energy range from 0.75 to 6 MeV. The measured X-ray production cross sections are compared to the predictions of the First Born approximation, the ECPSSR theory and the ECUSAR theory. A comparison of the ytterbium M-shell X-ray production cross sections with these theories is made for two different sets of fluorescence yields and Coster-Kronig factors that are further modified for multiple ionization.
The development of new efficient afterglow phosphors is currently hampered by a limited understanding of the persistent luminescence mechanism. Radioluminescence (RL) and x-ray absorption measurements on the persistent phosphor SrAl2O4:Eu,Dy were combined to reveal possible valence state changes for the rare earth (co)dopants. Traps in the phosphor material are quickly filled when exposing thermally emptied SrAl2O4:Eu,Dy powder to xrays. On the same time scale a partial oxidation of Eu2+ to Eu3+ is observed by x-ray absorption near-edge spectroscopy (XANES), while for the trivalent dysprosium the valence state remains unchanged. The impact of these observations on the recently proposed models for persistent luminescence is discussed.
Jul 25, 2011 ... Koji Mukai's Bibliography. Invited Reviews. Mukai, K. 1994, "ASCA PV Phase Observations of Cataclysmic Variables," in "New Horizon of X-ray ...
The X-ray intensity ratio K_#beta#/K_#alpha# has been measured by using a 10 mCi "5"5Fe source (Mn K X-rays) and high resolution Si(Li) detector system coupled to a computer-controlled multichannel analyzer over the range of 15#<=#Z#<=#22. Correction have been made to the measured relative intensities (K_#alpha# and K_#beta# X-rays) for self-absorption in the sample, air, Be-window absorption and detection efficiency. The results are compared with those of other experiments and with the Scofield calculations. (author) 13 refs.; 3 figs.; 2 tabs.
Multi-kilo-electron-volt x-ray microscopy will be an important laser-produced plasma diagnostic at future megajoule facilities such as the National Ignition Facility (NIF). However, laser energies and plasma characteristics imply that x-ray microscopy will be more challenging at NIF than at existing facilities. We use analytical estimates and numerical ray tracing to investigate several instrumentation options in detail, and we conclude that near-normal-incidence single spherical or toroidal crystals may offer the best general solution for high-energy x-ray microscopy at NIF and similar large facilities. Apertured Kirkpatrick{endash}Baez microscopes using multilayer mirrors may also be good options, particularly for applications requiring one-dimensional imaging over narrow fields of view. {copyright} 1998 Optical Society of America
We briefly review capabilities and requirements for future instrumentation in UV- and X-ray astronomy that can contribute to advancing our understanding of the diffuse, highly ionised intergalactic medium.
We present preliminary analysis for the feasibility of the attosecond x-ray pulses at a proposed FERMI@ELETTRA free electron laser (FEL) [1]. In part 1 we restrict ourselves to minimal modifications to the proposed FEL and consider a scheme for attosecond x-ray production which can be qualified as a small add-on to a primary facility. We demonstrate that at 5-nm wavelength our scheme is capable for production of pulses with an approximate duration of 100 attoseconds at approximately 2 MW peak power and with an absolute temporal synchronization to a pump laser pulse. In part 2 we propose to use an FEL amplifier seeded by a VUV signal and to follow it by the scheme for attosecond x-ray production described in part 1.
The Warm-Hot Intergalactic Medium (WHIM) arises from shock-heated gas collapsing in large-scale filaments and probably harbours a substantial fraction of the baryons in the local Universe. Absorption-line measurements in the ultraviolet (UV) and in the X-ray band currently represent the best method to study the WHIM at low redshifts. We here describe the physical properties of the WHIM and the concepts behind WHIM absorption line measurements of H I and high ions such as O VI, O VII, and O VIII in the far-ultraviolet and X-ray band. We review results of recent WHIM absorption line studies carried out with UV and X-ray satellites such as FUSE, HST, Chandra, and XMM-Newton and discuss their implications for our knowledge of the WHIM.
Digital radiography for diagnosis of chest diseases using Fuji Computed Radiography (FCR) was evaluated. The results were as follows; 1. Compared to the conventional chest X-ray films, various types of image enhancement could be made by manipulation of the digital information such as tone conversion, spatial frequency modification etc. 2. Digital radiography lessens the X-ray exposure dose and will ultimately permit speedy transmission of image data from outlying clinics to central processing hospitals. 3. Digital radiographic images are useful in chest X-ray diagnosis especially in mass surveys for lung cancer and in primary care medicine because of its full imaging capability. (author).
... to-continuum X-ray intensity ratio [5]. For ence in the means [7]. In addition, washing samples on thin films, the characteristic X- lymphocytes in NH ...
The available data of single X-ray pulsars, their wind nebulae, and the SNRs which are connected to some of these sources are analysed. It is shown that electric field intensity of neutron stars tears off charged particles from the surface of neutron star and triggers the acceleration of particles. The charged particles are accelerated mainly in the field of magnetodipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magnetodipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.
In the framework of the search for a ceramic material usable in the radioactive waste storage, uranium and thorium phosphates have been investigated. Their experimental synthesis conditions have been entirely reviewed, they lead to the preparation of four new compounds: U(UO{sub 2})(PO{sub 4}){sub 2}, U{sub 2}O(PO{sub 4}){sub 2}, UCIPO{sub 4}, 4H{sub 2}O, and Th{sub 4}(PO{sub 4}){sub 4}P{sub 2}O{sub 7}. Experimental evidenced are advanced for non existent compounds such as: U{sub 3}(PO{sub 4}){sub 4}, U{sub 2}O{sub 3}P{sub 2}O{sub 7} and Th{sub 3} (PO{sub 4}){sub 4}. Characterization by several techniques (X-rays and neutron powder diffractions, UV-Visible and Infra-red spectroscopies, XPS,...) were performed. The ab initio structure determination of U(UO{sub 2})(PO{sub 4}){sub 2} has been achieved by X-rays and refined by neutron diffractions. Through its physico-chemical analysis, we found that this compound was a new mixed valence uranium ...
The recently observed X-ray synchrotron emission from four supernova remnants (SNRs) has strengthened the evidence that cosmic-ray electrons are accelerated in SNRs. We show that if this is indeed the case, the local electron spectrum will be strongly time-dependent, at least above roughly 30 GeV. The time dependence stems from the Poisson fluctuations in the number of SNRs within a certain volume and within a certain time interval. As far as cosmic-ray electrons are concerned, the Galaxy looks like actively bubbling Swiss cheese rather than a steady, homogeneously filled system. Our finding has important consequences for studies of the Galactic diffuse gamma-ray emission, for which a strong excess over model predictions above 1 GeV has recently been reported. While these models relied on an electron injection spectrum with index 2.4 (chosen to fit the local electron flux up to 1 TeV), we show that an electron injection ...
The results of investigation into a new series of Z-even nuclei - precursors of delayed protons (PDP) -"6"5Ge, "8"9Se, "9"3Kr, "8"1Zr, and "8"5Mo are presented. PDP were obtained by irradiation of targets in the following reactions: Zn(He, 2n) "6"5Ge, 22 MeV; "4"0Ca("3"2S, 2 pn) "1"9Se, 100 MeV; "6"0Ni ("1"60, 3 n), "7"3Kr, 75 MeV; "5"2Cr ("3"2S, 3n)"8"1Zr, 110 MeV; "5"6Fe("3"2S, 3n)"8"5Mo, 120 MeV. The targets (self-sustaining foils of thickness approximately 1.2 mg/cm"2) were placed at an angle of 15 deg to the direction of the ion beam. Upon irradiation targets were moved downwards into a measuring position. The spectra of protons, X and gamma-rays, and also the spectra of p - x, p-#gamma#, x - #gamma# coincidences accompanying the decay of "6"5Ge, "6"9Se,"7"3Kr and "8"1Zr, and "8"5Mo were measured. The measured half-lives are equal, to 31.5+-1.9, 27.3+-0.5, 28.5+-1.1, 6.3+-0.5, and 5.6 +-0.9 s respectively. The experimental spectra are compared with the calculated ones. The proton ...
This paper introduces the JNM Special Issue on the development of a first wall for the reaction chamber in a laser fusion power plant. In this approach to fusion energy a spherical target is injected into a large chamber and heated to fusion burn by an array of lasers. The target emissions are absorbed by the wall and encapsulating blanket, and the resulting heat converted into electricity. The bulk of the energy deposited in the first wall is in the form of X-rays (1.0-100 keV) and ions (0.1-4 MeV). In order to have a practical power plant, the first wall must be resistant to these emissions and suffer virtually no erosion on each shot. A wall candidate based on tungsten armor bonded to a low activation ferritic steel substrate has been chosen as the initial system to be studied. The choice was based on the vast experience with these materials in a nuclear environment and the ability to address most of the key remaining ...
Tl(InS_2)_1_-_x(FeSe_2)_x single crystals (where x=0; 0.001; 0.005; 0.01 and 0.015) were grown by the Bridgman-Stockbarger method. Obtained single crystals were crystallized in monoclinic structure. The present paper deals with experimental results relative to X-ray dosimetric characteristics of the Tl(InS_2)_1_-_x(FeSe_2)_x solid solutions at 300 K. Installation URS-55a was the source of radiation. X-ray radiation dose (E) falling on the crystals is measured by the crystalline X-ray dosimeter DRGZ-02. The value of X-ray conductivity coefficient K_#sigma# characterising X-ray sensitivity is defined as K_#sigma#= (#sigma#_E-#sigma#_0)/E#sigma#_0. where #sigma#_E is conductivity under the effect of X-ray radiation by intensity E, #sigma#_0 is conductivity in the lack of radiation. Comparing X-ray dosimetric characteristics of TlInS_2 and ...
It is shown that it is necessary to take into account locality of the analysis and to introduce additional corrections for partial capture of matrix and fluorescent subexcitation by matrix during quantitative X-ray spectral microanalysis of finely dispersed materials. Cast two-phase (#alpha#+#beta#) titanium alloy VT3-1 is chosen as an investigation object.
Smith-Purcell (S-P) radiation is produced when electrons graze the surface of a grating. Calculations based on the theory of diffraction radiation show that, given severe restrictions on e"--beam quality, S-P radiation is highly efficient. Efficient S-P x-ray generation requires relativistic e"- beams having a transverse momentum and dimension whose product approaches the Heisenberg uncertainty limit.
The solid state reaction between a Pd thin film and a Si substrate produces a single new phase, Pd/sub 2/Si, for temperatures <700/sup 0/C. When the substrate is a single crystal of (111) surface orientation, this process is particularly interesting because the silicide grows epitaxially. Growth of epitaxial interfacial Pd/sub 2/Si was the focus of this study using X-ray diffraction techniques.
A radioactive particle was analyzed to discover the composition of the inactive material of the particle. The method uses the x-ray line spectrum of the K series caused by electron irradiation of the particle in the electron microscope. Iron and aluminum or silicon (the last two could not be distinguished) were found as inactive components in the particle. (D.L.C.)
The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).
Structure of ferrite in drawn pearlitic steel containing 0.9 mass% C was investigated with X-ray diffraction technique using synchrotron radiation. In the detailed analysis of diffraction peaks of ferrite during the drawing process, it was experimentally revealed that the transformation of ferrite from bcc to bct due to the supersaturation of carbon in ferrite of heavily drawn pearlitic steel.
Structure of ferrite in drawn pearlitic steel containing 0.9 mass% C was investigated with X-ray diffraction technique using synchrotron radiation. In the detailed analysis of diffraction peaks of ferrite during the drawing process, it was experimentally revealed that the transformation of ferrite from bcc to bct due to the supersaturation of carbon in ferrite of heavily drawn pearlitic steel.
Radiometric X-ray fluorescence analysis was used for the determination of Mn, Fe, Cu, Zn and Pb in wastewater and sludges from three wastewater treatment plants in Bratislava (SR). Metals were determined in wastewaters after preconcentration by 8-hydroxyquinoline and in sludges by drying and pressing to pellets. "2"3"8Pu and "1"0"9Cd was used for excitation of fluorescence radiation. (author).
Radionuclide X-ray fluorescence analysis was used for the determination of Cr, Fe, Cu, Zn and Ph in industrial wastewaters (from surface treatment of metals and glasses) after precipitation of determined elements by 8-hydroxyquinoline. (author).
The feasibility was studied of the application of radionuclide X-ray fluorescence analysis to the identification and determination of chemical elements in the air. A description of the method is presented, the main stages of the analysis are discussed (sample preparation and standards, selection of radioactive radiation sources, geometry of measurement and evaluation of results). The method is illustrated on the determination of elements Fe, Cu, Zn, Br, and Pb in air samples taken in the city of Prague. (author) 2 tabs., 2 figs., 14 refs.
The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.
Our studies on K#beta#/K#alpha# X-ray intensity ratios of some of the technologically important 3d-transition metal compounds have been reviewed. Comparison of the experimental results with single-configuration Dirac-Fock calculations provided important information on the valence states of the transition metals in various compounds, which can be helpful in understanding the nature of bonding in the compounds. (author)
ORNL has developed the technology to detect hidden explosives in luggage using Xray and neutron detection devices. The Federal Aviation Administration has ordered the airlines to buy and install Thermal Neutron Analysis (TNA) units. The combined pulsed-neutron and X-ray interrogation inspection (CPNX) system developed at ORNL uses less radioactive materials as well as being more sensitive to weapons, electronic devices and plastic explosives.
Radionuclide x-ray fluorescence method was used in the determination of Cr, Ni and other heavy metals content in wastewater of an engineering plant taken both before and after chemical treatment. Toxic effects of the wastewaters using Allium cepa root tip cells were tested. (author) 8 refs.; 2 tabs.
Determination of Mn, Fe, Cu, Zn, Hg, Pb, Br, Se, Rb, Sr and Cd in the medicinal plants by radionuclide X-ray fluorescence analysis (using "2"3"8Pu, "2"4"1Am/Ag and "1"2"5I) is described. (author). 12 refs., 2 tabs.
Heavy metals (Pb, Cd, Mn, Cu, Zn, Fe) were determined in surface waters in the surroundings of the depositories of the mining shrubs in the region of Banska Stiavnica (SR) by radionuclide X-ray fluorescence analysis. Allowed concentrations of the determined metals are exceeded numerously (multiplicity in some cases was 10"3-10"6). (author).
The free electron laser (FEL) FLASH at DESY in Hamburg is the first x-ray FEL ever built. Many new developments were necessary in order to exploit the unique properties of this novel light source for scientific experiments. The facility has constantly been improved and several major upgrades have been made or are currently underway. This paper reviews the main characteristics of the user facility as well as the major developments and upgrades.
A radiometric method was elaborated for surface density determinations of the adhesive layer of plasters by radionuclide X-ray fluorescence using the 17.47 keV bremsstrahlung of "1"4"7Pm/Mo. The bremsstrahlung line excites the 8.63 keV characteristic K#alpha# line of Zn contained in the adhesive layer of the plaster as a filling material in the form of ZnO. In homogeneous adhesive layers the Zn content is proportional to surface density. (author).
Cesium and selenium intake of cultivated mushrooms (Agaricus bisporus), with these elements previously added to culture medium, has been examined from the viewpoint of health- and environmental protection. The process of measuring has been carried out by the radionuclide X-ray fluorescence technique. Treatments of the elementary substance with Se salt appears to influence the Se content of the mushrooms to a significant extent. Cs intake is of considerable importance, as this element is accumulated by mushrooms. (author)
The applicability of the radionuclide X-ray fluorescence analysis (RXFA) for qualitative and quantitative evaluation of environmental plant samples is discussed and examples of determination of Mn, Fe, Ni, Cu, Zn, Pb in samples of apple trees are given. The instrumentation, the standard and sample preparation are also presented.
Radionuclide X-ray fluorescence method was used for the determination of Fe and Zn in healing plants (Sage, Peppermint, Stinging, Common Agrimony, Milfoil, Ribwort, Tansy, White Dead-Nettle). "2"3"8Pu exciting source and Si/Li semiconductor detector were used for the determination. (author)
Fe and Zn were determined in various parts of maize (Zea mays) in dependence on quantity of organic substrate EKOFERT as organic fertilizer in soil, using radionuclide X-ray fluorescence analysis. The increase of quantity of organic substrate EKOFERT in soil causes a decrease of heavy metal concentrations in certain parts of the plant. (author). 4 refs., 1 tab.
Radionuclide X-ray fluorescence method with Si/Li semiconductor detector and "2"3"8Pu exciting source was used for the determination of Cu, Ni, Zn and Pb in plant samples (Taraxacum officinale) from various localities near the highway D-61 Bratislava-Trnava (SR). (author) 2 refs.; 1 fig.; 1 tab.
Radionuclide X-ray fluorescence method with Si/Li semiconductor detector and "2"3"8Pu exciting source was used for the determination of Cu, Ni, Pb, and Zn in soil samples from various localities near the D-61 Bratislava-Trnava highway (CSFR). (author) 1 ref.; 1 tab.
The possible existence of preferential B-site disorder in A-15 compounds recently claimed on the basis of x-ray powder diffraction data but questioned from the viewpoint of known phase diagrams is examined for some Nb-based compounds of this type. It is concluded that x-ray powder data do not allow the determination of both order and compositional variables as suggested, and the latter must therefore be determined by some other method. (author).
Chemical influences on the relative Ksub(..beta..)/Ksub(..cap alpha..) x-ray intensity ratio up to five per cent were found for different chemical constitutions of Cr, Mn, Fe and Cu by very precise PIXE measurements. In the discussion of these effects, screening of 3p electrons by a varying 3d valence charge, as well as polarizational effects are of importance.
Chemical influences on the relative Ksub(#nu#)/Ksub(#alpha#) x-ray intensity ratio up to five per cent were found for different chemical constitutions of Cr, Mn, Fe and Cu by very precise PIXE measurements. In the discussion of these effects, screening of 3p electrons by a varying 3d valence charge, as well as polarisational effects are of importance. (author).
Chemical effects on the intensity ratio of LX-ray of molybdenum compounds irradiated by 11-keV electrons and by 3-MeV protons were studied using an x-ray crystal spectrometer. It was found that the intensity ratios of L_#gamma#_1/L_#beta#_1 markedly decrease with the increase of ionicity of molybdenum compounds, except for the case of metallic molybdenum. (author).
3d occupation numbers of the transition elements corresponding to various types of atomic configurations are calculated by means of the linear muffin-tin orbital (LMTO) method. This data is used with the multiconfiguration Dirac-Fock (MCDF) X-ray intensity ratios to estimate the electron populations of the 3d metals in alloys.
3d occupation numbers of the transition elements corresponding to various types of atomic configurations are calculated by means of the linear muffin-tin orbital (LMTO) method. This data is used with the multiconfiguration Dirac-Fock (MCDF) X-ray intensity ratios to estimate the electron populations of the 3d metals in alloys.
An energy dispersive x-ray fluorescence technique was used for the determination of Titanium (Ti) and Zirconium (Zr) in red mud by using a standard addition method. An annular {sup 241}Am source is employed for excitation of K shells of elements. 13 refs., 2 figs., 1 tab.
We present a sample preparation method for measuring magnesium in individual whole lymphocytes by electron probe X-ray microanalysis. We use Burkitt's lymphoma cells in culture as the test sample and compare X-ray microanalysis of individual cells with atomic absorption analysis of pooled cell populations. We determine the magnesium peak-to-local continuum X-ray intensity ratio by electron probe X-ray microanalysis and calculate a mean cell magnesium concentration of 39 +/- 19 mmol/kg dry weight from analysis of 100 cells. We determine a mean cell magnesium concentration of 34 +/- 4 mmol/kg dry weight by atomic absorption analysis of pooled cells in three cell cultures. The mean cell magnesium concentrations determined by the two methods are not significantly different. We find a 10% coefficient of variation for both methods of analysis and a 30% coefficient of variation in magnesium concentration among ...
An numerical method was developed for measuring radiant temperature using a set of absorption-foils coupled to soft xray streak camera, SXRSC, in laser plasma experiments. An numerical code, SCC, was given. An x-ray intensity ratio vs temperature was calculated for Parylene, C_3H_6, Mylar and Aluminium. A suitable range of the measuring temperature was discussed to some absorber.
A survey is presented of studies dealing with radionuclide X-ray fluorescence analysis (RXFA) of impurities in the air, water, soil, sediments and biological materials, mainly blood, urine, hair, soft tissues and bones. Tabulated are lists of published works on RXFA of the air, water and biological materials. (ES).
Iron doped semiconducting nanoparticles Sn1-xFexO2 with x=0, 0.001, 0.002, 0.003, 0.004, 0.01 and 0.03 were prepared by a sol-gel method. The X-ray diffraction, Transmission Electron Microscopy measurements confirm the rutile structure with no impurity phase. The three characteristic lines of electron spin resonance (ESR) are observed in the doped samples for all compositions, which is a clear evidence for rhombic Fe3+ in rutile phase. The line width of ESR increases with increase in Fe concentration due to induced disorder. The spin-pumping effect is observed at temperatures below 250 K for the samples with x=0.01 and 0.03. However, based on the Curie-Weiss susceptibility, iron is in paramagnetic state and is subject to weak antiferromagnetic interaction. Blue shift in the optical band gap is observed with increase in the Fe content. -- Graphical abstract: The ESR spectra reveal that the nature of Fe in Sn1-xFexO2 samples is isolated rhombic ...
Epitaxial CeO_2 buffer layers were fabricated by pulsed laser deposition (PLD) on r-cut sapphire substrates. An atomically flat CeO_2 surface with a high density of nanodots was formed by a self-assembly process. Scanning transmission electron microscopy and energy-dispersive X-ray spectroscopy investigation showed that the nanodots were CeO_2 other than impurities. YBa_2Cu_3O_7_-_#delta# (YBCO) thin films were then grown on the annealed and the as-grown CeO_2-buffered sapphires by PLD. The transport measurement results showed that the nanodots enhanced the effective pinning potential and significantly increased critical current density (J _c). Especially, YBCO films with an annealed CeO_2 buffer layer showed a high J _c peak when the applied field was directed along the c-axis of YBCO. Cross-section transmission electron microscopy investigation revealed that the J _c peaks in YBCO with annealed CeO_2 buffer layer is caused by c-axis correlated pinning sites, such ...
X-ray scattering from lyophilized proteins or protein-rich samples is characterized by the presence of two characteristic broad peaks at scattering angles equivalent to momentum transfer values of 0.27 and 0.6 nm{sup -1}, respectively. These peaks arise from the interference of coherently scattered photons. Once the conformation of a protein is changed, these two peaks reflect such change with considerable sensitivity. The present work examines the possibility of characterizing the most common cause of hemolytic anaemia in Egypt and many Mediterranean countries; {beta}-thalassemia, from its X-ray scattering profile. This disease emerges from a genetic defect causing reduced rate in the synthesis of one of the globin chains that make up hemoglobin. As a result, structurally abnormal hemoglobin molecules are formed. In order to detect such molecular disorder, hemoglobin samples of {beta}-thalassemia patients are collected, lyophilized and ...
A curved crystal X-ray spectrographs of reflection type spherical geometry was required based on the Johann scheme. Due to their high efficiency and resolution, X-ray spectrographs of focusing spectrograph spatial resolution are suitable for detecting weak X-ray spectra in spectrometers for laser fusion research. Spherically bent mica crystal with a radius of curvature of 380 mm was used in the spectrometer. The Bragg angle of the crystal analyzer was 51 degree. The image plate was employed to obtain high spatial resolution and a narrow spectral band width, with an effective area of 30 mm x 80 mm. The designed optical path of the X-ray spectrometer beam was 980 mm long from the source to the crystal and the detector. The first experiment was carried out at the 20 J energy laser facility of Research Center of Laser Fusion, China Academy of Engineering Physics. X-ray spectra in an ...
Radiotherapy can be very significant as the treatment for ocular lesions, eyes need to be preserved as properly as possible on their functions and cosmetics. The application of conventional Xray therapy has been gradually abandoned as conventional Xray therapy ceased to be accepted as the general treatment for malignant tumors. Consequently the necessity of electron beam therapy has been rising even as the substituted method for conventional Xray therapy. The department of radiology of Gunma University was obliged to establish a new therapy for ocular lesions, and has been trying electron beam therapy since 1973. It is concluded that electron beam therapy is not at all inferior to conventional Xray therapy as reported above. Basic therapeutic methods for ocular lesions are the following: 1) For epidermoid carcinoma, ...
An x-ray fluorescence spectrometer was designed and fabricated which nondestructively determines the thickness of aluminum cladding at small suspected thin spots in the inner or outer surface of actinide reactor tubes. The analysis method is based on the difference in absorption of actinide L/sub #alpha#/ and L/sub #beta#/ fluorescent x-rays in passing through the cladding. Calibration plots of the logarithm of the L/sub #beta#//L/sub #alpha#/ x-ray intensity ratio versus cladding thickness are linear to at least 40 mils for U-Al, U_3O_8-Al, and PuO_2-Al substrates. Accuracy and precision of the experimentally determined cladding thickness and evaluated for both uranium and plutonium substrates. Experimental thickness data are reported for 618 quality assurance analyses on six Mark 41 PuO_2-Al target tubes. An x-ray fluorescence cladding thickness monitor operated with a computer-controlled fluoroscope ...
This dissertation describes the evaluation of many-pixel Cadmium-Zinc-Telluride (CdZnTe) hard-X-ray detectors for future use with the High Energy Replicated Optics (HERO) telescope being developed at Marshall Space Flight Center. The detector requirements for the HERO application are good energy resolution (sufficient to resolve cyclotron features and nuclear lines), spatial resolution of ∼200 μm, minimal charge loss of absorbed Xrays, and minimal sensitivity to the background environment. This research concentrates on assessing the suitability of these detectors for the focus of HERO, and includes the development of a simulation of the physics involved in an X-ray-detector interaction, a study of the intrinsic material properties, measurements with prototype detectors such as the energy and spatial resolution, charge loss, and X-ray background reduction through ...
The resolution of X-ray diffraction microscopy is limited by the maximum dose that can be delivered prior to sample damage. In the proposed Serial Crystallography method, the damage problem is addressed by distributing the total dose over many identical hydrated macromolecules running continuously in a single-file train across a continuous X-ray beam, and resolution is then limited only by the available molecular and X-ray fluxes and molecular alignment. Orientation of the diffracting molecules is achieved by laser alignment. We evaluate the incident X-ray fluence (energy/area) required to obtain a given resolution from (1) an analytical model, giving the count rate at the maximum scattering angle for a model protein, (2) explicit simulation of diffraction patterns for a GroEL-GroES protein complex, and (3) the frequency cut off of the transfer function following iterative solution of the phase problem, ...
We review the recent development of bendable x-ray optics used for focusing of beams of soft and hard x-rays at the Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory and at the Linac Coherent Light Source (LCLS) x-ray free electron laser (FEL) at the Stanford Linear Accelerator Center (SLAC) National Accelerator Laboratory. For simultaneous focusing in the tangential and sagittal directions, two elliptically cylindrical reflecting elements, a Kirkpatrick-Baez (KB) pair, are used. Because fabrication of elliptical surfaces is complicated, the cost of directly fabricated tangential elliptical cylinders is often prohibitive. Moreover, such optics cannot be easily readjusted for use in multiple, different experimental arrangements, e.g. at different focal distances. This is in contrast to flat optics that are simpler to manufacture and easier to measure by conventional interferometry. The tangential figure of ...
The devised radionuclide analyzer for the determination of total sulfur in coal includes two radionuclide sources with different energies, which are accommodated in collimators fitted with adjustable diaphramgs. The sample compartment is located between the two sources. Moreover, an X-ray fluorescence standard can be slid into the sample compartment. A proportional detector for X-ray fluorescence and scattered gamma radiation is located off the sample compartment. The input of the proportional detector is interfaced to the output of a high-voltage supply, the output, to the information input of a control-and-evaluation unit. One of the control outputs of the control-and-evaluation unit is connected to the input of the sliding mechanism for the X-ray fluorescence standard. This arrangement enables automatic energy calibration of the analyzer. The analyzer can measure not only total sulfur in coal by radionuclide ...
We present the 24 #mu#m rest-frame luminosity function (LF) of star-forming galaxies in the redshift range 0.0 #<=# z #<=# 0.6 constructed from 4047 spectroscopic redshifts from the AGN and Galaxy Evolution Survey of 24 #mu#m selected sources in the Booetes field of the NOAO Deep Wide-Field Survey. This sample provides the best available combination of large area (9 deg"2), depth, and statistically complete spectroscopic observations, allowing us to probe the evolution of the 24 #mu#m LF of galaxies at low and intermediate redshifts while minimizing the effects of cosmic variance. In order to use the observed 24 #mu#m luminosity as a tracer for star formation, active galactic nuclei (AGNs) that could contribute significantly at 24 #mu#m are identified and excluded from our star-forming galaxy sample based on their mid-IR spectral energy distributions or the detection of X-rayemission. Optical emission line ...
This study aims to investigate the difference in the interaction of antimicrobial peptides with two classes of zwitterionic peptides, phosphatidylethanolamines (PE) and phosphatidylcholines (PC). Further experiments were performed on model membranes prepared from specific bacterial lipids, lipopolysaccharides (LPS) isolated from Salmonella minnesota. The structure of the lipid-peptide aqueous dispersions was studied by small-and wide-angle X-ray diffraction during heating and cooling from 5 to 85 C. The lipids and peptides were mixed at lipid-to-peptide ratios 10-10000 (POPE and POPC) or 2-50 (LPS). All experiments were performed at synchrotron soft condensed matter beamline A2 in Hasylab at Desy in Hamburg, Germany. The phases were identified and the lattice parameters were calculated. Alamethicin and melittin interact in similar ways with the lipids. Pure POPC forms only lamellar phases. POPE forms lamellar phases at low temperatures that upon heating transform ...
Increasingly stringent pollution regulations have spurred a broad interest in the reduction of engine emissions. Two strategies can be considered: after-treatment or engine emissions reduction. For Diesel engines, after-treatment has a high cost induced by the required technology and implementation issues. In this context, the Highly Premixed Combustion combustion mode (HP C) has emerged as a topic of major interest in recent years. It represents one of the most promising ways for new generation of CI engines using high Exhaust Gas Recirculation (EGR) rates. Experimentation on the test bench brought the proof of significant emission reduction. However, actual vehicle implementation implies frequent transient which fall far beyond steady state experimentation on the test bench. Several key challenges have to be addressed. With this combustion technology; accurate torque balancing at all engine modes is a ...
Alpha-particle emissioninduced by neutron bombardment of carbon has been studied from threshold to over 30 MeV using the spallation neutron source at WNR/LAMPF. Targets include thin foils of CH{sub 2} and thicker foils of CH and polycrystalline graphite. Comparisons are made with evaluated data. Values for KERMA (kinetic energy released in materials) based on the results will be presented and compared with those obtained through other experimental approaches.
Y2Te4O11:Eu3+ and Y2Te5O13:Eu3+ single crystals in sub-millimeter scale were synthesized from the binary oxides (Y2O3, Eu2O3 and TeO2) using CsCl as fluxing agent. Crystallographic structures of the undoped yttrium oxotellurates(IV) Y2Te4O11 and Y2Te5O13 have been determined and refined from single-crystal X-ray diffraction data. In Y2Te4O11, a layered structure is present where the reticulated sheets consisting of edge-sharing [YO8]13- polyhedra are interconnected by the oxotellurate(IV) units, whereas in Y2Te5O13 only double chains of condensed yttrium-oxygen polyhedra with coordination numbers of 7 and 8 are left, now linked in two crystallographic directions by the oxotellurate(IV) entities. The Eu3+ luminescence spectra and the decay time from different energy levels of the doped compounds were investigated and all detected emission levels were identified. Luminescence properties of the Eu3+ cations have been interpreted in consideration ...
Silver iron oxide nanoparticles of fairly small size (average diameter approximately 1 nm) with narrow size distribution have been synthesized by the interaction of colloidal beta- Fe2O3 and silver nanoparticles. The surface morphology and size of these particles have been analyzed by using atomic force microscopy (AFM), field emission scanning electron microscopy (FESEM) and transmission electron microscopy (TEM). Their structural analysis has been carried out by employing x-ray diffraction (XRD), selected-area electron diffraction (SAED), optical and infrared (IR) spectroscopic techniques. The ageing of these particles exhibits the formation of self-assembly, possibly involving weak supramolecular interactions between Ag(I)O4 and Fe(III)O4 species. These particles display the onset of absorption in the near-infrared region and have higher absorption coefficient in the visible range compared to that of its precursors. Magnetic measurements ...
The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform the data analysis. WAND system minimum detectable activities (MDAs) for point sources range from ...
Consensus reached in the last few years that fourth generation light source will most likely be a X-ray or a UV coherent source based on single-pass high-gain free electron laser (FEL), such as Self Amplified Spontaneous Emission (SASE), or seeded high-gain harmonic-generation (HGHG) free electron lasers. High-gain (>10"7) required for single-pass FEL puts great constrain on the quality of electron beam, and demands detailed distribution information of electron beam in six-dimension. The typical accelerator system for single-pass FEL consists of a photocathode RF gun injection system, a linac and magnetic bunch compressors, and a long undulator. The major challenges in beam diagnostics for single-pass FEL are to characterize the pico-seconds high-brightness electron beam in six-dimension produced by photocathode RF gun injector, and improve the stability and reliability of the photocathode RF gun injection system. Characterization of short ...
The adhesion of a Mg:Ag cathode to the tris-(8-hydroxyquinoline) aluminum (Alq{sub 3}) in organic light emitting devices (OLEDs) can be greatly enhanced by a remote plasma treatment of the Alq{sub 3} layer using either air or N{sub 2} prior to metal deposition. The altered surface properties which lead to increased sticking coefficients of Mg and Ag, as well as enhanced adhesion, are attributed to the introduction of new functional groups into the organic layer, as observed by X-ray photoelectron spectroscopy (XPS). The storage life of the plasma treated devices in air without any capping treatment, as judged by a visible deterioration of the cathode, was increased by approximately five to six times compared to untreated OLEDs. Current-voltage characteristics and EL efficiency, however, were shown to deteriorate for devices incorporating either an air or an N{sub 2} plasma treated Alq{sub 3} layer. For OLEDs subjected to short treatment times with an N{sub 2} ...
A study on oxygen-plasma treatment of ink-jet paper is presented. Paper was exposed to a weakly ionized, highly dissociated oxygen plasma with an electron temperature of 5 eV, a positive-ion density of 8 x 1015 m-3 and a density of neutral oxygen atoms of 5 x 1021 m-3. Optical emission spectroscopy (OES) was applied as a method for detection of the reaction products during the plasma treatment of the paper. OES spectra between 250 and 1000 nm were measured continuously during the plasma treatment. The wettability of the samples before and after the plasma treatment was determined by measuring the contact angle of a water drop. The appearance of the surface-functional groups was determined by using high-resolution x-ray photoelectron spectroscopy (XPS), while changes in the surface morphology were monitored with scanning electron microscopy (SEM). Already after 1 s of the plasma treatment the surface, which was originally hydrophobic, changed to ...
Lithium ion conducting glass ceramics composed of the crystalline conductive phase Li{sub 1.4}Al{sub 0.4}(Ge{sub 1-x}Ti{sub x}){sub 1.6}(PO{sub 4}){sub 3}(x=0-1.0) with the Nasicon-type structure have been synthesized and characterized by DTA, X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM) and complex impedance techniques. The experimental results indicated that the glass ceramics were mainly composed of solid solution Li(Ge{sub 1-x}Ti{sub x}){sub 2}(PO{sub 4}){sub 3} formed by LiGe{sub 2}(PO{sub 4}){sub 3} and LiTi{sub 2}(PO{sub 4}){sub 3} in the whole x range and showed conductivity over 10{sup -4} S/cm at room temperature. The maximum room temperature lithium ion conductivity of 6.21x10{sup -4} S/cm with an activation energy as low as 0.32 eV was obtained for the Li{sub 1.4}Al{sub 0.4}(Ge{sub 0.67}Ti{sub 0.33}){sub 1.6}(PO{sub 4}){sub 3} treated at 950 C for 18 h. Mechanisms for the enhancement of {sigma}{sub ...
Successful interface engineering requires compositional and electronic material characterization as a prerequisite for understanding and intentionally generating interfaces in photovoltaic devices. The paper gives an overview with several examples, all referring to Cu(In,Ga)(S,Se){sub 2} ('CIGSSe')-based solar cells, with an emphasis on characterization using highly specialized methods, such as elastic recoil detection analysis, X-rayemission spectroscopy and photoelectron spectroscopy using synchrotron and ultraviolet light for excitation, inverse photoemission spectroscopy and Kelvin probe force microscopy. First, the determination of the depth profile of the band gap energy E{sub g} in the absorber layer is demonstrated. The modification of E{sub g} towards both interfaces is discussed in terms of beneficial electronic effects. Next, the interface between absorber and buffer layers with alternative and promising non-toxic ...
The crystal structure of borophosphates ABPO{sub 5} (A = alkaline earth or Pb) was resolved on a polycrystalline sample using the Rietveld method. The x-ray diffraction patterns data show that ABPO{sub 5} crystallize in a centrosymmetric space group P3{sub 1}21 and their structure is related to the borogermanates REBGeO{sub 5} with a stillwellite-type structure. Pr{sup 3+} ion was used as a local structural probe to corroborate the structural resolution results. Absorption and fluorescence spectra of A{sub 1-x}Pr{sub x}BP{sub 1-x}Ge{sub x}O{sub 5} (A alkaline earth or Pb; x = 0.05) have been investigated at different temperatures. At 9 K the 3{sup H}{sub 4}{yields}{sup 3}P{sub 0} transition of trivalent praseodymium ion (4f{sup 2} configuration) is observed as a single line. This indicates a unique crystallographic site for the rare earth ion in these compounds replacing the divalent cation. Energy level schemes were deduced from the low-temperature spectroscopic ...
The crystal structure of borophosphates ABPO_5 (A = alkaline earth or Pb) was resolved on a polycrystalline sample using the Rietveld method. The x-ray diffraction patterns data show that ABPO_5 crystallize in a centrosymmetric space group P3_121 and their structure is related to the borogermanates REBGeO_5 with a stillwellite-type structure. Pr"3"+ ion was used as a local structural probe to corroborate the structural resolution results. Absorption and fluorescence spectra of A_1_-_xPr_xBP_1_-_xGe_xO_5 (A alkaline earth or Pb; x = 0.05) have been investigated at different temperatures. At 9 K the 3"H_4#->#"3P_0 transition of trivalent praseodymium ion (4f"2 configuration) is observed as a single line. This indicates a unique crystallographic site for the rare earth ion in these compounds replacing the divalent cation. Energy level schemes were deduced from the low-temperature spectroscopic measurements. Comparing the electronic level splittings of studied ...
Analysis of the dynamics of the cavity radiation of a coherently pumped correlated emission laser is presented. The phase fluctuation and dephasing are found to affect the time evolution of the two-mode squeezing and intensity of the cavity radiation significantly. The intensity and degree of the two-mode squeezing increase at early stages of the process with time, but this trend changes rapidly afterwards. It is also shown that they increase with phase fluctuation and dephasing in the strong driving limit, however the situation appears to be opposite in the weak driving limit. This essentially suggests that the phase fluctuation and dephasing weaken the coherence induced by a strong driving mechanism so that the spontaneous emission gets a chance. The other important aspect of the phase fluctuation, in this regard, is the relaxation of the time at which the maximum squeezing is manifested as well as the time in which the ...
Primordial black holes are unique probes of cosmology, general relativity, quantum gravity and non standard particle physics. They can be considered as the ultimate particle accelerator in their last (explosive) moments since they are supposed to reach, very briefly, the Planck temperature. Upper limits on the primordial black hole number density of mass $M_{\\star} = 5 10^{14}$ g, the Hawking mass (born in the big-bang terminating their life presently), is determined comparing their predicted cumulative $\\gamma$-ray emission, galaxy-wise, to the one observed by the EGRET satellite, once corrected for non thermal $\\gamma$-ray background emissioninduced by cosmic ray protons and electrons interacting with light and matter in the Milky Way. A model with free gas emissivities is used to map the Galaxy in the 100 MeV photon range, where the peak of the primordial black hole emission ...
The risks of genetic, leukemia and malignant diseases from medical X-ray diagnostic examinations were estimated using the frequency of radiographic and fluoroscopic exposures per diagnostic examination, child expectancy, leukemia and malignancy significant factors, and using a weighting factor determined on the basis of data concerning the cancer mortality among atomic bomb survivors in Nagasaki and of a recommendation of International Commission of Radiological Protection. The organ or tissue doses with respect to the stochastic risks were determined with ionization chambers and thermoluminescent dosimeters placed at the positions of the organs or tissues in a RANDO woman phantom which was exposed to diagnostic X-rays according to technical factors of typical radiographic and fluoroscopic examinations obtained from a nationwide survey. The resultant risks by age-group and type of radiographic and fluoroscopic examination are tabulated in terms ...
Purpose: Reconstruction of organ doses of selected organs and tissues from radiographic settings and exposure data collected during chest X-ray examinations of children of various age groups performed in Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007. Materials and Method: The dosimetric data of all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 119 150 chest radiographs of all age groups. Reconstruction of organ doses in 40 organs and tissues in X-ray examinations of the chest was performed based on the conversion factor concept. Results: The radiation exposure of organs in projection radiography is determined by the exact site of the organs relative to the edges of ...
This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is ...
We present a sample preparation method for measuring magnesium in individual whole lymphocytes by electron probe X-ray microanalysis. We use Burkitt's lymphoma cells in culture as the test sample and compare X-ray microanalysis of individual cells with atomic absorption analysis of pooled cell populations. We determine the magnesium peak-to-local continuum X-ray intensity ratio by electron probe X-ray microanalysis and calculate a mean cell magnesium concentration of 39 +- 19 mmol/kg dry weight from analysis of 100 cells. We determine a mean cell magnesium concentration of 34 +- 4 mmol/kg dry weight by atomic absorption analysis of pooled cells in three cell cultures. The mean cell magnesium concentrations determined by the two methods are not significantly different. We find a 10% coefficient of variation for both methods of analysis and a 30% coefficient of variation in magnesium concentration among ...
The quantitative determination of oxide concentration by laser-induced breakdown spectroscopy is relevant in various fields of applications (e.g.: analysis of ores, concrete, slag). Calibration free laser-induced breakdown spectroscopy and the multivariate calibration are among the methods employed for quantitative concentration analysis of complex materials. We measured the intensity of neutral and ionized atomic emission lines of oxide materials by laser-induced breakdown spectroscopy and we modified the calibration free laser-induced breakdown spectroscopy method to increase the accuracy. The concentration of oxides was obtained by using stoichiometric relations. Sample materials were prepared from oxide powder (Fe{sub 2}O{sub 3}, MgO, CaO) by mixing and pressing. The concentration was 9.8-33.3 wt.% Fe{sub 2}O{sub 3}, 7.6-33.3 wt.% MgO and 33.3-81.2 wt.% CaO for different ...
A measurement of the magnetic form factor of a ferromagnetic actinide compound of UTe with circularly polarized X-rays is reported. The present geometrical configuration of the measurement gives a form factor of L(k)+0.3S(k), where L(k) and S(k) are the form factors of the orbital and the spin magnetic moment, respectively. We have combined the X-ray magnetic form factor with the neutron one which gives L(k)+2S(k) (G. Busch et al.: J. Phys. C 12 (1979) 1391), and have deduced L(k) and S(k) separately. The obtained profiles of L(k) and S(k) show that the orbital and the spin magnetic moments are spatially spread out more than those calculated for a free uranium ion. (author).
A measurement of the magnetic form factor of a ferromagnetic actinide compound of UTe with circularly polarized X-rays is reported. The present geometrical configuration of the measurement gives a form factor of L(k)+0.3S(k), where L(k) and S(k) are the form factors of the orbital and the spin magnetic moment, respectively. We have combined the X-ray magnetic form factor with the neutron one which gives L(k)+2S(k) (G. Busch et al.: J. Phys. C 12 (1979) 1391), and have deduced L(k) and S(k) separately. The obtained profiles of L(k) and S(k) show that the orbital and the spin magnetic moments are spatially spread out more than those calculated for a free uranium ion. (author).
The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)
We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.
Total M shell X-ray production cross section for 11 elements with 69 #<=# Z #<=# 92 have been measured using an incident photon energy of 5.96 keV. Measurements have been performed using an "5"5Fe annular source and a Si(Li) detector. Average M shell fluorescence yield at each incident photon energy has been deduced, using the experimental total M X-ray production cross section and theoretical M shell photoionization cross section. Present experimental results are compared with other experimental and theoretical values. Reasonable agreement (to within 0.3-28%) is typically obtained between present and other experimental and theoretical values.
The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase imaging with respect to standard absorption imaging, in the ...
The Micro-X instrument is a NASA funded, rocket borne X-ray imaging spectrometer planned for launch in January 2011. An array of Transition Edge Sensors (TESs) will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. This will be a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat sink, and will be read out by a SQUID time division multiplexer. X-rays will be focused onto the TES array of 128 pixels on a 600 micron pitch by a conically approximated Wolter optic with an effective area of 200 cm2. The spectrometer will have a field of view of 11.8 arcmin. We describe the design and development progress of the instrument.
We have studied L x-rays from 64 MeV iodine projectile in collision with various gas targets, Z_2 #18, do not arise from selective M subshell vacancy population, has been conclusively established by the observations by Datz et al (1971) and by Saha et al (1996) that the measured intensity ratio of the Ll and L#alpha# lines, which arise because of transitions from different M subshells into the same L, subshell, does not show any periodic behaviour with Z, but stays rather constant. Differences in the measured L#beta#_1/L#alpha# intensity ratio of iodine with 7"+ and 24"+ charge states impinging on Kr target established the minor role of the electrons in the N shell of the projectile in the x-ray production mechanism. (author)
Simulations of the x-ray free-electron laser (FEL) oscillator are presented that include transverse effects and realistic Bragg crystal properties with the two-dimensional code GINGER. In the present cases considered the radiation divergence is much narrower than the crystal acceptance, and the numerical algorithm can be simplified by ignoring the finite angular bandwidth of the crystal. In this regime GINGER shows that the saturated x-ray pulses have 109 photons and are nearly Fourier-limited with peak powers in excess of 1 MW. Wealso include preliminary results for a four-mirror cavity that can be tuned in wavelength over a few percent, with future plans to incorporate the full transverse response of the Bragg crystals into GINGER to more accurately model this tunable source.
The X-ray storage phosphor CsBr:Eu2+ in form of needle image plates is believed to be a promising alternative to the granular BaFBr:Eu2+ with regard to PSL yield and spatial resolution. Unfortunately, CsBr:Eu2+ exhibits poor radiation hardness, which is caused by a migration of europium ions initiated by naturally existing defect centers like (Eu2+-VCs)-centers and X-ray generated MEu-centers. It will be shown that the formation of (Eu2+-O2?)-dipoles at the expense of (Eu2+-VCs)-dipoles, incorporated by thermal annealing in O2-containing and humid atmosphere, does not improve the radiation stability. There is, however, a strong improvement in the radiation hardness by codoping of CsBr:Eu2+ with lithium ions, which is accompanied by a complete suppression of the previously observed MEu-cent...
The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on ...
The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on ...
The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on ...
The results of experiments received on the plasma focus (PF) device with energy stored equal 4 kJ are represented. Photos of the current plasma sheath (CPS), pre-pinch, sphere-like plasma formations are produced with help of the electron-optical converter contained a gated micro-channel plate (MCP) and the CCD-camera imaging system in the visible region. The redial velocity of the CPS is about 107 cm/s. Neon plasma electron density measured with help of the interferograms in the visible region and the spectra in the soft X-ray region is equals to 3?1018 cm-3. Electron temperature is equal to about 200 eV. Discharge integral photos were obtained with help of the soft X-ray pinhole camera. Pictures with 2 ?s resolution of the plasma luminescence above PF anode region were made by CCD-camera.
This Final Report documents the research accomplishments achieved in the first phase of operations of a new Advanced Photon Source beam line (7-ID MHATT-CAT) dedicated to real-time x-ray studies. The period covered by this report covers the establishment of a world-class facility for time-dependent x-ray studies of materials. During this period many new and innovative research programs were initiated at Sector 7 with support of this grant, most notably using a combination of ultrafast lasers and pulsed synchrotron radiation. This work initiated a new frontier of materials research: namely, the study of the dynamics of materials under extreme conditions of high intensity impulsive laser irradiation.
The use of nondestructive evaluation (NDE) methods is proposed for characterization of transuranic (TRU) waste stored at the Radioactive Waste Management Complex. These NDE methods include real-time x-ray radiography, real-time neutron radiography, x-ray and neutron computed tomography, thermal imaging, container weighing, visual examination, and acoustic measurements. An integrated NDE system is proposed for characterization and certification of TRU waste destined for eventual shipment to the Waste Isolation Pilot Plant in New Mexico. Methods for automating both the classification waste and control of a complete nondestructive evaluation/nondestructive assay system are presented. Feasibility testing of the different NDE methods, including real-time x-ray radiography, and development of automated waste classification techniques are covered as part of a five year effort designed to yield a production waste characterization ...
We summarize recent developments in x-ray microscopy of polymers by focusing on the characterization of organic electronic devices. The quantitative compositions of model polymer blends have been mapped at a resolution of {approx}35 nm. Since it could be inferred that these devices have structures smaller than 35 nm, quantitative compositional mapping at length scales below the present resolution limit of x-ray microscopy is required. Organic devices thus serve to both highlight the success of NEXAFS microscopy to date, but to also outline the very real need for higher spatial resolution. New approaches to create improved optics or different acquisition modalities are required if x-ray microscopy is to make sustained contributions to such an important area of research as organic devices.
An experiment on the K#beta#/K#alpha# characteristic X-ray intensity ratio in silver was performed at VEC Centre, Calcutta using the #alpha#-beams at energies 40 MeV and 50 MeV employing a Si(Li) detector system on-line. The results show that the K#beta#/K#alpha# X-ray intensity ratio at energies 40 and 50 MeV are 0.215 #+-# 0.006 and 0.216 #+-# 0.006, respectively, which indicates no change with beam energy and in accordance with the earlier reports. The present experiment shows the feasibility of studying the K#beta#/K#alpha# ratios as a function of beam energy in different regions of periodic table. Experiments in elements belonging to the 3d shell and their compounds are suggested to look for the chemical effects and their dependence on #alpha#-energy. (author). 7 refs.
A technique is proposed to generate electron beam with ultralow transverse emittance through laser assisted transverse-to-longitudinal emittance exchange. In the scheme a laser operating in the TEM10 mode is used to interact with the electron beam in a dispersive region and to initiate the emittance exchange. It is shown that with the proposed technique one can significantly downsize an x-ray free electron laser (FEL), which may greatly extend the availability of these light sources. A hard x-ray FEL operating at 1.5 {angstrom} with a saturation length within 30 meters using a 3.8 GeV electron beam is shown to be practically feasible.
We have measured K-edge X-ray absorption spectra of argon in sputtered aluminum films at a synchrotron radiation facility (the Photon Factory). We found that the energy and shape of white line change when the film is annealed at 500 C and the spectrum becomes resembling that of argon implanted in silicon. From the analyses of the X-ray absorption spectra and TEM observation we concluded that argon exists as very small atom clusters with a diameter less than 1 nm or exist as isolated atoms in the as-sputtered aluminum film, and that the size of the clusters become as big as 10 nm diameter when the film is heated. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)
In this study, Kb/Ka X-ray intensity ratios, Formula Not Shown , Formula Not Shown production cross-sections and K fluorescence yields of Co and Cu and Lb/La X-ray intensity ratios, Formula Not Shown , Formula Not Shown production cross-sections and Formula Not Shown average fluorescence yields of Ag in pure metals and in different alloy compositions were measured. In this study, alloying effects on the Formula Not Shown production cross-sections of Co and Cu were investigated and changes interpreted according to the rearrangement of valance state electrons and the charge transfer process between the 3d elements (Co and Cu) and Ag.
X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more precision of refraction-angle values than existing methods.
X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more precision of refraction-angle values than existing methods.
Most surface-acoustic-wave and thin-film optical devices are made by the planar fabrication process. The exposure of the pattern in the polymer film is the first and most crucial step in ensuring desired device geometry, dimensional control, and freedom from pattern distortion. The methods of exposing the polymer film include: optical projection, conventional contact printing, conformable photomask contact printing, holographic recording, scanning electron beam lithography, projection electron lithography, and x-ray lithography. In this paper scanning electron beam lithography, conformable photomask contact printing, holographic recording, and x-ray lithography are discussed. In the last section, ion beam etching of relief structures is discussed.
A number of difficult technical challenges need to be solved in the fields of accelerator and free-electron laser (FEL) technologies in order to build an X-ray FEL. One of the tasks well suited to the Advanced Photon Source Low Energy Undulator Test Line (LEUTL) is to take the intermediate step of solving some of the problems of single-pass FEL operation in the ultraviolet range. The existing Advanced Photon Source (APS) linac, in addition to its role of supply positrons for the APS storage ring, will also be used to generate the particle beam for the LEUTL. Here, the design of the magnetic system for the high gain soft x-ray free electron laser is described.
A galactose-specific seed lectin was purified from the legume Spatholobus parviflorus and crystallized using the hanging-drop vapour-diffusion technique. Thecrystals belonged to space group P1, with unit-cell parameters a = 60.998, b=60.792, c = 78.179-, = 101.32, = 91.38, = 104.32. X-ray diffraction data were collected under cryoconditions (100-K) to a resolution of 2.04- using a MAR image-plate detector system mounted on a rotating-anode X-ray (Cu-K) generator. Molecular replacement using legume-lectin coordinates as a search model gave a tetrameric structure.
This paper presents results about the characterisation of the biomass fly ashes sourced from a thermal power plant and from a co-generation power plant located in Portugal, and the study of new cement formulations incorporated with the biomass fly ashes. The study includes a comparative analysis of the phase formation, setting and mechanical behaviour of the new cement-fly ash formulations based on these biomass fly ashes. Techniques such as X-ray diffraction (XRD), X-ray fluorescence spectroscopy (XRF), thermal gravimetric and differential thermal analysis (TG/DTA), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and environmental scanning electron spectroscopy (ESEM) were used to determine the structure and composition of the formulations. Fly ash F1 from the t...
This investigation of a brain cancer cluster in Missouri used two approaches to investigate associations with potential risk factors. In a case-control study in a rural town, we interviewed surrogates of cases and controls about potential risk factors. We found a statistically significant positive association of brain cancer with reported exposure to dental x-rays. Occupation was not associated with the cluster in the rural town. In a standardized proportional mortality study for the state of Missouri, we calculated the observed and expected proportion of brain cancers by occupation and industry in Missouri decedents. We found that motor vehicle manufacturers, beauty shop workers, managers and administrators, elementary school teachers, and hairdressers and cosmetologists had significantly elevated proportions of brain cancer. Brain tumors are inconsistently associated with occupation in the literature. Further study of brain cancer etiology with respect to dental ...
Composite nitrides (such as BN, TiN) are widely used in various industrial applications because of their extreme wear and corrosion resistance, thermal and electrical properties. in order to obtain composite materials with these optimal properties, it is important to elucidate whether any chemical reactions occur at nitride/metal interfaces, e.g., those involving BN-Ti/TiN. Materials of interest include the deposition by PVD of Ti and TiN on BN substrates. Some of these systems were then subjected to varying degrees of physical and thermal alteration. Detailed X-ray photoelectron spectroscopy (XPS) has therefore been rendered of these interfaces using cross-sectional display and sputter etching. Resulting structural and morphological features have been investigated with transmission electron microscopy (TEM) and X-ray diffraction (XRD). Diffusion of the nitridation, oxynitride formation and interfacial growth are of general interest.
Stimulated bremsstrahlung in an undulating electric field in the lasing beam direction (electric wiggler) was shown to be possible from the quantum- mechanical viewpoint. Herein, this possibility is scrutinized from the viewpoint of classical electrodynamics. It is found that if stimulated bremsstrahlung in a transverse undulating magnetic field (magnetic wiggler) occurs, stimulated bremsstrahlung in the electric wiggler must also occur. We further show that a free electron laser (FEL) using a magnetic wiggler to provide a catalyzer field for stimulated bremsstrahlung cannot serve as a practical FEL operating in the soft x-ray region from both theoretical and experimental viewpoints. On the other hand, the authors demonstrate that the FEL using a traveling wake field in a two-beam elliptical pill-box cavity is well suited as a source of coherent radiation in the soft x-ray region.
The Stardust sample return capsule will return to Earth in January 2006 with primitive debris collected from Comet 81P/Wild-2 during the fly-by encounter in 2004. In addition to the cometary particles embedded in low-density silica aerogel, there will be microcraters preserved in the Al foils (1100 series; 100 {micro}m thick) that are wrapped around the sample tray assembly. Soda lime spheres ({approx}49 {micro}m in diameter) have been accelerated with a Light Gas Gun into flight-grade Al foils at 6.35 km s{sup -1} to simulate the capture of cometary debris. The experimental craters have been analyzed using scanning electron microscopy (SEM) and x-ray energy dispersive spectroscopy (EDX) to locate and characterize remnants of the projectile material remaining within the craters. In addition, ion beam induced secondary electron imaging has proven particularly useful in identifying areas within the craters that contain residue material. Finally, ...
Culex mosquitoes introduce the pathogens responsible for filariasis, West Nile virus, St. Louis encephalitis, and other diseases into humans. Currently, traps baited with oviposition semiochemicals play an important role in detection efforts and could provide an environmentally friendly approach to controlling their populations. The odorant binding proteins (OBPs) in the female's antenna play a crucial, if yet imperfectly understood, role in sensing oviposition cues. Here, we report the X-ray crystallography and NMR 3D structures of OBP1 for Culex quinquefasciatus (CquiOBP1) bound to an oviposition pheromone (5R,6S)-6-acetoxy-5-hexadecanolide (MOP). In both studies, CquiOBP1 had the same overall six-helix structure seen in other insect OBPs, but a detailed analysis revealed an important previously undescribed feature. There are two models for OBP-mediated signal transduction: (i) direct release of the pheromone from an internal binding pocket in a ...
A way to synthesize the transient zwitterionic silylene L'Si: 8 {L'=CH[(C=CH(2))CMe(N(tBu))(2)]} and achieve its facile dimerization to the remarkable N-heterobicyclic disilane 8(2) is described. At first, employing the beta-diketiminate ligand L [L=CH(CMeN(tBu))(2)], both starting materials LH (2) and its N-lithium salt LLi (3) can react with SiBr(4) to yield the silylene precursor L'SiBr(2) (4) by silicon-induced C-H activation at an exocyclic methyl group on the backbone of the ligand. Compound 4 reacts with SiBr(4) above room temperature to afford the unexpected terminal CH(SiBr(3))-substituted dibromosilane 6 along with the unique tricyclic trisilane 7. Reduction of 4 with KC(8) at 0 degrees C furnishes the novel N-heterobicyclic disilane 8(2), which is a formal dimer of the desired zwitterionic silylene L'Si: (8). It has been reasoned that compound 8(2) may results from [4+1] cycloaddition of two molecules of 8 to give the transient dimer 8(2)', which ...