A somatic dose index for diagnostic radiology  

International Nuclear Information System (INIS)

Irradiation of the human body in diagnostic X-ray procedures results in different absorbed doses in the various body organs. A somatic dose index in formulated by applying the relative sensitivity of the human to each of the most important somatic effects and utilizing the absorbed dose in the affected organs. This quantity is used to convey a cumulative somatic impact and is computed for common radiographic views in diagnostic radiology as a function of beam quality for a nominal IR entrance exposure. Using typical X-ray beam qualities and exposures, the frequency of the various radiographic views that make up an examination and the frequencies of the various examinations in the national population, illustrative examples of the application of the somatic dose index are presented. (author).

1978-01-01

3

Organ doses received by atomic bomb survivors during radiological examinations at the Radiation Effects Research Foundation  

Energy Technology Data Exchange (ETDEWEB)

When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS ...

1991-08-01

4

Organ doses received by atomic bomb survivors during radiological examinations at the Radiation Effects Research Foundation  

International Nuclear Information System (INIS)

When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. ...

1991-01-01

5

X-ray dose enhancement effects  

International Nuclear Information System (INIS)

A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.

6

Structural and magnetic studies on the enhancement of the giant magnetoimpedance by ion irradiation  

British Library Electronic Table of Contents (United Kingdom)

The mechanism of abrupt increase of the giant magneto impedance (GMI) ratio in the ion irradiated Co-based amorphous ribbon has been investigated. The grazing incident X-ray diffraction and transmission electron microscope were used to characterize the samples before and after ion irradiation. The GMI-ratio considerably increased in the ion irradiated samples and the GMI response showed strong dependence on the driving frequencies. The Barkhausen noise (BN) signals are increased for the Ar ion irradiated sample with dose of 1x10^1^7 ion/cm^2. The results are interpreted in terms of GMI variation associated with domain wall dynamics.

2011-01-01

9

Carbon beam irradiation of human monolayer cells  

Energy Technology Data Exchange (ETDEWEB)

The effect of the heavy particle irradiation on cell survival is different from that of X-ray irradiation. In Japan, heavy particles will be applied to cancer patients in the near future. This study was performed to determine the effect that carbon particle irradiation exerts to human monolayer cells in vitro, in comparison with the effect of 200 kVp X-ray. Two human cell lines, HeLaS3 and RMUG, were used. The irradiation was carried out by the RIKEN ring cyclotron and 200 kVp X-ray. The experimental procedure is explained. Also split dose experiment was carried out by applying equally divided doses at intervals of 2 - 4 hours. The Bragg curve of 135 MeV/n carbon beam through the lucite plates with different thickness is given. Thus the different LETs were obtained. The survival curves for 200 kVp ...

1993-12-31

10

Method of describing dose distributions in computer design of teleradiotherapy  

International Nuclear Information System (INIS)

Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.

11

Melatonin exerts differential actions on X-ray radiation-induced apoptosis in normal mice splenocytes and Jurkat leukemia cells  

British Library Electronic Table of Contents (United Kingdom)

Abstract: The ability of melatonin as a potent antioxidant was used as a rationale for testing its antiapoptotic ability in normal cells. Recently, melatonin was shown to possess proapoptotic action by increasing reactive oxygen species in certain cancer cells. The modification of radiation-induced apoptosis by melatonin and the expression of apoptosis-associated upstream regulators were studied in normal mice splenocytes and Jurkat T leukemia cells. C57BL/6 mice were exposed to a single whole body X-ray radiation dose of 2 Gy with or without 250 mg/kg melatonin pretreatment. The Jurkat cells were divided into four groups of control, 1 mm melatonin alone, 4 Gy irradiation-only and melatonin pretreatment before irradiation. The highest level of apoptosis in the normal splenic white pulp was...

2009-01-01

12

Long-term effects of prenatal x-ray of human females: reproductive experience  

Energy Technology Data Exchange (ETDEWEB)

A cohort of singleton black human females exposed to diagnostic x-ray in utero and controls matched by parity, hospital of birth and birthdate have been followed to ages 25 to 30 years in Baltimore, Maryland. The search for possible effects of prenatal irradiation has focused on health, growth, development, and reproductive experience of exposed and control women. This paper reports findings related to reproductive experience. From an original data set of 1458 matched exposed-control pairs of women, questionnaire responses were received from 1109 exposed and 1124 control women including 852 each from pairs in which both the exposed and control woman responded. After careful search for alternative explanations of the findings, the authors concluded that females exposed in utero to low doses of x-ray (probably 1 to 5 rads) had significant increases in their rates of early onset of menses, births at age 15 ...

1981-09-01

13

Effects of post-irradiation annealing in alpha-particle bombarded molybdenum  

International Nuclear Information System (INIS)

Structural variations in 39-MeV alpha-particle irradiated (Tsub(irr) = 60 deg C) polycrystalline molybdenum during post-irradiation annealing were studied by X-ray and TEM methods. Despite the high density of irradiation induced defects in the structure of the specimen X-ray measurements showed zero relative lattice parameter change after an irradiation dose of 1.1 x 10"-_2 dpa. However, during the annealing #delta#a/a was changed in the positive range, exhibiting two peaks - at 100 and 300 deg C - whereas the damage structure detected by TEM indicated no changes. Analysis of the results leads to the conclusion that in the range 100 to 250 deg C migration of isolated vacancies and their annihilation at interstitial clusters as well as possible formation of new vacancy clusters occur. The second peak on the #delta#a/a temperature dependence ...

14

Behavior of triterpenes from Maytenus aquifolium Martius ('espinheira santa') upon X- and gamma-rays irradiation  

International Nuclear Information System (INIS)

The behavior of the triterpenes friedelin and friedelan-3-ol, contained on the leaves of Maytenus aquifolium Martius (Celastraceae), upon several doses of X- and #gamma#-rays (10 to 100 kGy), was investigated by high resolution gas chromatography (HRGC) and high resolution gas chromatography -mass spectrometry (HRGC-MS). The friedelin content has not changed with #gamma#-irradiation, but the content of friedelan-3-ol decreased around 17% at doses of 10, 20 and 40 kGy and around 27% at doses of 60, 80 and 100 kGy. The levels of both triterpenes remained unchanged even at higher X-ray doses. Lupen-3-one was detected by HRGC-MS. (author).

15

Determination of radiation exposure and significance of its influential factors for X-rayed children in the GDR  

International Nuclear Information System (INIS)

After having discussed the peculiarities of children in X-ray diagnosis the application of the effective as well as the mean equivalent doses as to the determination of the radiation exposure in children is represented. In using computerized tomograms to determine position and extent of an organ the exposure by repeated X-raying was calculated referring to the entrance dose. Entrance dose measurements for all types of X-ray examination in hospitals and ascertainments of the frequency of radiograms in 20 X-ray departments were used to determine per capita and collective doses, resp., in several age groups. Alltogether, the per capita dose of children in the GDR amounts to 30% of that of adults. Conclusions were drawn as to taking measures to further reduction of radiation exposure: (1) Technical ...

1988-01-01

16

The elevation of blood levels of zinc protoporphyrin in mice following whole body irradiation  

Energy Technology Data Exchange (ETDEWEB)

Elevation of zinc protoporphyrin (ZPP) levels in the blood has served as an indicator of lead poisoning and iron deficiency anemia for many years. We have discovered that sublethal doses of whole body irradiation with x-rays also elevates ZPP 2-3-fold over normal levels. The ZPP level does not begin to increase until days 12-14 postirradiation and peaks between days 18 and 20 before returning to normal levels between days 28 and 35. Increasing the radiation dose delays the onset of the rise in ZPP, but does not affect the magnitude of the elevation. At lethal doses, ZPP elevation is not observed. Neither of the two previously described mechanisms that cause elevations of ZPP, namely iron deficiency and inhibition of ferrochelatase, are responsible for the radiation-induced elevation of ZPP. The elevation of ZPP appears to be correlated with the recovery of the hematopoietic system ...

1984-05-01

17

Nuclei with protrusions - tailed nuclei - and radiation cytogenetic markers in X-irradiated lymphocytes in vitro  

International Nuclear Information System (INIS)

The results of an investigation into tailed nuclei (TN) and features of dose dependence on frequency of the binuclear cells with TN in human lymphocyte cultures by cytogenetic block method upon X-ray radiation dose are presented. The frequencies of metaphases with dicentric and ring chromosomes are investigated concurrent with TN formed upon completion of first postradiation mitosis. Frequency of the appearance of binuclear cells with nuclei having outgrowth into the cytoplasmic space and arises after first mitosis in human lymphocyte culture is linear-square dependent on the X-irradiation at doses from 0.0 to 4.0 Gy. Positive correlation between frequency of cells with tailed nuclei and frequency of metaphases of first mitosis having dicentric and rings was established. Apparently, formation such TN is connected with dicentric and rings

18

Comparison of enhanced device response and predicted x-ray dose enhancement effects on MOS oxides  

Energy Technology Data Exchange (ETDEWEB)

The response of MOS capacitors to low- and medium-energy x-ray irradiation is investigated as a function of gate material (TaSi or Al), oxide thickness, and electric field. Measured device response is compared with predictions based on discrete ordinates and Monte Carlo code simulations of dose enhancement effects, coupled with recent estimates of electron-hole recombination in MOS oxides. In comparisons of 10-keV x-ray and Co-60 irradiations of Al-gate MOS capacitors at an oxide electric field of 1 MV/cm, it is found that predictions and experiments agree to within better than 20 percent for oxide thicknesses ranging from 35 to 1060 nm. For capacitors having TaSi/Al gates, predictions and experiments agree to within better than 30 percent at 1 MV/cm, with the largest differences occurring for 35-nm gate oxides. At other electric fields, the disagreement between experiment and ...

1988-12-01

19

Comparison of enhanced device response and predicted x-ray dose enhancement effects on MOS oxides  

International Nuclear Information System (INIS)

The response of MOS capacitors to low- and medium-energy x-ray irradiation is investigated as a function of gate material (TaSi or Al), oxide thickness, and electric field. Measured device response is compared with predictions based on discrete ordinates and Monte Carlo code simulations of dose enhancement effects, coupled with recent estimates of electron-hole recombination in MOS oxides. In comparisons of 10-keV x-ray and Co-60 irradiations of Al-gate MOS capacitors at an oxide electric field of 1 MV/cm, it is found that predictions and experiments agree to within better than 20 percent for oxide thicknesses ranging from 35 to 1060 nm. For capacitors having TaSi/Al gates, predictions and experiments agree to within better than 30 percent at 1 MV/cm, with the largest differences occurring for 35-nm gate oxides. At other electric fields, the disagreement between experiment and ...

1988-07-12

20

X-radiation effects on muscle cell membrane electrical parameters  

International Nuclear Information System (INIS)

Early effects of 100 Kilorads of X-rays on muscle cell membrane properties have been measured in sartorius muscles from Leptodactylus ocellatus. Threshold strength for rectangular current pulses increased 10% after irradiation, and action potential propagation velocity decreased 10%. Passive membrane parameters were calculated from potential responses to sub-threshold current pulses, assuming conventional cable theory. Specific membrane conductance increased to 18% after irradiation, membrane capacitance increased 14%, and length constant decreased 10% but membrane time constant was unchanged. Cell diameter decreased 5%, and resting membrane potential decreased 8%. Membrane parameters during an action potential were also evaluated by the phase-plane and current-voltage plot techniques. Irradiation significantly decreased the action potential amplitude, the excitation potential, and the maximum rates of ...

21

Degredation of superconductive properties in type A 15 compounds after irradiation  

International Nuclear Information System (INIS)

The influence of irradiation with 2.6 MeV H and He nuclei on the superconducting properties (critical temperature Tsub(c), critical current Isub(c)) of the intermetallic compound Nb_3Sn was studied. Irradiation led to a significant lowering of Tsub(c), while Isub(c) is increasing with the radiation dose. This is assumed to be due to the formation of active pinning centres in the lattice. There is a fast drop of Isub(c) after a peak value has been reached. Annealing of the samples (600-1,000"0C) led to an almost complete recovery of the initial value of Tsub(c). X-ray diffraction showed that irradiation causes considerable distortions of the lattice while the A15 crystal structure is retained. The causes of the radiation effects related to structural defects are discussed. (GSCH).

22

Influence of the X-ray radiation on the lifetime of carriers in the p-n junctions of Si and Ge  

International Nuclear Information System (INIS)

Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of lifetime of the charge carriers with the increase of ...

23

A comparison of patient doses in lumbar spine radiography from various X-ray units in Poland  

Energy Technology Data Exchange (ETDEWEB)

A number of diagnostic X-ray units in Poland were subjected to analysis. The air kerma on X-ray tables was measured for the X-ray parameters used routinely during lumbo-sacral spine radiography of standard adult patient. Measurements of air kerma were performed using TLD made of lithium-fluoride. The doses received by patients in different X-ray departments can differ more than two orders of magnitude (from 0.42 mGy up to 72.11 mGy), for the same X-ray examination. The dose can be significantly reduced if fluorescent screens made from components of rare earth are used. (author). 10 refs, 1 fig., 2 tabs.

1995-12-31

24

Nuclear radiation detectors on II-VI compounds  

International Nuclear Information System (INIS)

Nuclear radiation detectors in integral execution were produced by successive epitaxial growth from vapor phase of Zn Te and Cd Se thin layers onto scintillating Zn Se (Te) crystals. The irradiation of combined Zn Se (Te) - Zn Te - Cd Se detectors by Cu_K_a X-rays leads to the appearance of photoreceiver e.m.f., which tends to saturation with the increase of X-ray radiation dose reaching the value of 0.34-0.40 V at 200 R/min. The short circuit current dependence of irradiation dose power is linear. The matching factor for detectors with Zn Te-Cd Se photoreceivers with different doping levels is 0.68-0.92. The absolute monochromatic sensitivity is 0.32-0.35 m A/m W at a quantum efficiency 0.58-0.61 and a time constant 2 x 10"-"4 s. The calculated dose sensitivity for Zn Se(Te)-Zn Te-Cd Se combined detectors at the ...

1993-10-13

25

X-ray and UV-light irradiation effects on oxide superconducting thin films  

International Nuclear Information System (INIS)

Oxide superconducting thin films were irradiated with X-rays and ultra-violet (UV) light, and induced radiation effects on electrical and chemical properties were examined by transport measurement, X-ray diffraction analysis (XRD), diamagnetization measurement and X-ray photoemission spectroscopy (XPS). After irradiation for ErBa_2Cu_3O_x films with X-rays emitted from a Rh tube for 100 hours, superconductivity was remarkably damaged, destroying the zero-resistance state. The UV-light irradiation for Bi_2Sr_2CaCu_2O_x films was performed in He gas of about 500 Pa with a low pressure mercury lamp. The superconductivity was gradually degraded with the UV irradiation time up to 70 minutes. In both cases, adequate oxygen-annealing treatments restored superconductivity. The X-ray photoemission spectra ...

26

Tissue oxygenation in a murine SCC VII tumor after X-ray irradiation as determined by EPR spectroscopy  

UK PubMed Central (United Kingdom)

PurposeThe goal of this study was to clarify the dynamics of tumor oxygen (partial pressure of oxygen, pO2) in SCC VII murine tumors in mice after X-ray...Full Text Available

2008-03-01

27

Fragmentation and ion-molecule reaction of diethylmercury radical cations: an ESR study in irradiated frozen freon matrices and spin trapping in liquid phase  

International Nuclear Information System (INIS)

The mono- and intramolecular cation-radicals (CR) reactions of diethylmercury in the CFCl_3, CFCl_2CF_2Cl matrices and CF_2BrCF_2Br and CFCl_3 freons vitrified mixture (1:1) were studied through the EPR method. Formation of radical products of transformations of the initial CR diethylmercury (X-ray radiation dose - 100-200 Gy at the temperature of 293 K) was studied through the spin trap of 2.4.6 - tri-tret-butylnitrosebenzene.

28

Medical irradiation and the use of the 'effective dose equivalent' concept  

International Nuclear Information System (INIS)

By applying the linear-dose effect relation, the weighting factors for total risks recommended by IRCP can be transformed to weighting factors for somatic effects. Another weighting factor Msub(s) has to be used which takes into account the dependence of the latent period for occurrence of malignant disease and the variation of the incidence with time. On this basis a somatically significant dose equivalent can be defined as 'the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by the various individuals', and an approximation has been derived for this. Tables are presented of the somatic effective dose equivalents calculated for different x-ray examinations for various organs and tissues. The S.E.D. equivalents have also ...

1980-03-01

29

Thermoluminescence studies in lead doped KCl and KBr crystals  

International Nuclear Information System (INIS)

Lead is known to enter substitutionally in divalent state when doped in alkali halides. When irradiated at room temperature these lead centers (Pb"+"+) act as traps for electrons knocked off from the halogen ions and become Pb"+ and Pb"0 (for large doses of irradiation). These changes could be followed in the optical absorption studies. These lead-doped crystals after X-ray irradiation yield a thermoluminescence output smaller than that observed in 'pure' crystals. However, two new glow peaks are observed in additions to those due to F-centers. In KCl : Pb and Kbr : Pb crystals part of the F-center glow preceds the new glow peaks. The new peaks are attributed to the Pb"+ and Pb"0 centers. The glow peak temperatures and trap depths for these peaks an obtained by total-curve fitting method are reported. (author).

1975-02-12

30

Patient doses in the Netherlands. [X-ray diagnosis and radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

Contributions to the population dose due to medical applications of ionising radiation are presented. It appears that contributions due to radiotherapy and X ray diagnosis are of comparable magnitude. To account for the age dependency of the radiation risks, contributions in terms of somatically significant dose equivalent are calculated as 0.3 mSv per caput per annum for X ray diagnosis and as 0.2 mSv per caput per annum for radiotherapy, the latter referring to only doses to organs outside the target volume. (author).

1991-01-01

31

X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography  

International Nuclear Information System (INIS)

Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a ...

2002-03-01

32

X-ray dosimetry of TlGaSe_2 single crystals  

International Nuclear Information System (INIS)

TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal ...

33

Survey of radiation doses to patients from the diagnostic use of X-rays  

International Nuclear Information System (INIS)

The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).

1977-06-01

34

Determination of Organ Doses During Radiological Examinations and Calculation of Somatically Significant Dose.  

Science.gov (United States)

Examples are used to demonstrate that a shift in the point of emphasis is necessary with regard to radiation hazard in medicinal X-ray diagnosis. The parameters employed in this study to calculate somatic dose (SD) and somatically significant dose (SSD) m...

1980-01-01

35

Use of a convolution/superposition-based treatment planning system for dose calculations in the kilovoltage energy range  

International Nuclear Information System (INIS)

A number of procedures in diagnostic radiology and cardiology make use of long exposures to x-rays from fluoroscopy units. Although numerous studies have been performed to measure or calculate skin dose from these procedures, there have only been a handful of studies to determine the dose to the other organs. This thesis was focused on devising a method to calculate the absorbed dose to underlying tissues and organs. The work was performed in several stages. First, a commercial convolution/superposition-based treatment planning system used in radiation oncology was modified and complemented to make it usable with the low energies of x-rays used in diagnostic radiology. This required generation of energy deposition kernels in the kilovoltage energy range. The kernels were generated using the EGS4 Monte Carlo system of codes and added to the treatment planning system. The treatment ...

2001-03-01

36

Radiation exposure to patients during hepatic interventional procedure  

International Nuclear Information System (INIS)

Objective: To investigate the X-ray radiation dose patients dealt with the hepatic intervention. Methods: Thermoluminescence and tissue-equivalent anthropomorphic phantom were used to measure the X-ray radiation dose in patients dealt with the hepatic intervention in 85 patients. Results: The peak skin dose in the patients who accepted hepatic intervention was from 179.95 to 1759.00 mGy, effective dose approached 29.22 mSv (male), 29.27 mSv (female). Conclusion: Hepatic intervention is now regarded as an important therapeutic method for liver cancer. However, the patients were exposed to too much X-ray radiation during interventional procedures. Some more effective protection should be taken to decrease the X-ray radiation dose accepted by patients. (authors)

2005-05-01

37

A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: a theoretical study on 10-MV X-ray dose calculations in thorax-like phantoms  

British Library Electronic Table of Contents (United Kingdom)

A convolution/superposition method is proposed for use with primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. It should be noted that the number of energy bins is usually about ten, and that the reconstructed X-ray spectra can reasonably be applied to media with a wide range of effective Z numbers, ranging from water to lead. The study was carried out for 10-MV X-ray doses in water and thorax-like phantoms with the use of open-jaw-collimated fields. The dose calculations were made separately for primary, scatter, and electron contamination dose components, for which we used two extended radiation sources: one was on the X-ray target and the other on the flattening filter. To calculate the in-air beam intensities at po...

2011-01-01

38

Regulation of the Low Dose Radiation Paracrine-Specific Anchorage-Independent Growth Response by Annexin A2  

Energy Technology Data Exchange (ETDEWEB)

ABSTRACT-Here we identify release of annexin A2 into the culture medium in response to low dose X-ray radiation exposure and establish functional linkages to an established paracrine factor-mediated anchorage-independent growth response. Using a standard bicameral coculture model, we observe that annexin A2 levels associated with non-irradiated neighboring cells seeded in the lower chamber (annexin A2 silenced [shRNA] JB6 cells) are increased upon coculture with irradiated (10-50 cGy) JB6 cells seeded in the upper chamber, relative to coculture with sham exposed JB6 cells seeded in the upper chamber, suggesting that annexin A2 released into the medium is capable of communicating in a paracrine fashion. Using a previously established coculture model, we observed that the paracrine factor-mediated anchorage-independent growth response to low dose X-ray radiation ...

2009-07-13

39

Trans-generational radiation-induced chromosomal instability in the female enhances the action of chemical mutagens  

Energy Technology Data Exchange (ETDEWEB)

Genomic instability can be produced by ionising radiation, so-called radiation-induced genomic instability, and chemical mutagens. Radiation-induced genomic instability occurs in both germinal and somatic cells and also in the offspring of irradiated individuals, and it is characterised by genetic changes including chromosomal rearrangements. The majority of studies of trans-generational, radiation-induced genomic instability have been described in the male germ line, whereas the authors who have chosen the female as a model are scarce. The aim of this work is to find out the radiation-induced effects in the foetal offspring of X-ray-treated female rats and, at the same time, the possible impact of this radiation-induced genomic instability on the action of a chemical mutagen. In order to achieve both goals, the quantity and quality of chromosomal damage were analysed. In order to detect trans-generational genomic instability, a total of 4806 ...

2008-04-02

40

ESR study of X-ray irradiated rare earth (Ln) ion-doped glaserite and Ln ion-doped langbeinite  

Energy Technology Data Exchange (ETDEWEB)

X-ray irradiation-induced paramagnetic radicals in rare earth (Ln) ion-doped glaserite and Ln ion-doped langbeinite were studied by means of ESR technique, aiming at developing the highly sensitive sensor for an ESR dosimetry. The samples were prepared by two kinds of procedures as follows. In one process, the glaserite (K{sub 3}Na(SO{sub 4}){sub 2}) matrix or the langbeinite (K{sub 2}Mg{sub 2}(SO{sub 4}){sub 3}) matrix were synthesized by heating the mixture of K{sub 2}SO{sub 4} and Na{sub 2}SO{sub 4} or the mixture of K{sub 2}SO{sub 4} and MgSO{sub 4} at 1023 K for 1 hour in He flow. The matrices obtained were mixed well with a fixed amount of Ln{sub 2}(SO{sub 4}){sub 3} (Ln=La, Eu, Gd, Lu) powder and heated at 1023 K for 1 hour in He flow. In the other process, the homogeneous mixture of a fixed amount of K{sub 2}SO{sub 4}, Na{sub 2}SO{sub 4} and Ln{sub 2}(SO{sub 4}){sub 3} powders or a fixed amount of K{sub 2}SO{sub 4}, MgSO{sub 4} and ...

1992-06-01

41

Grating-based X-ray phase imaging using multiline X-ray source  

International Nuclear Information System (INIS)

Differential phase-contrast X-ray imaging has been performed in a Talbot-Lau configuration, where a multiline X-ray source was used instead of a combination of a hard-X-ray multiple slit and a normal focus X-ray generator. When the multiple slit is used, a high aspect ratio structure is needed and slit width should be below 10 ?m for its function. The fabrication and use of such a multislit can be omitted using the presented configuration. The multiline X-ray source was developed by making grooves on a tungsten rotating anode, which was irradiated by an electron beam to generate X-rays. An array of 10?m line sources with a pitch of 30?m was formed and combined with a 4.5 ?m pitch phase grating and a 5.3 ?m pitch amplitude grating to generate differential phase contrast. With a total exposure time of 40 s, a differential phase image depicting ...

2009-07-01

42

Direct patterning of gold oxide thin films by focused ion-beam irradiation  

International Nuclear Information System (INIS)

For direct writing of electrically conducting connections and areas into insulating gold oxide thin films a scanning Ar"+ laser beam and a 30 keV Ga"+ focused ion beam (FIB) have been used. The gold oxide films are prepared by magnetron sputtering under argon/oxygen plasma. The patterning of larger areas (dimension 10-100 #mu#m) has been carried out with the laser beam by local heating of the selected area above the decomposition temperature of AuO_x(130-150 C). For smaller dimensions (100 nm to 10 #mu#m) the FIB irradiation could be used. With both complementary methods a reduction of the sheet resistance by 6-7 orders of magnitude has been achieved in the irradiated regions (e.g. with FIB irradiation from 1.5 x 10"7#OMEGA#/#square# to approximately 6 #OMEGA#/#square#). The energy-dispersive X-ray analysis (EDX) show a considerably reduced oxygen content in the irradiated areas, ...

2000-09-01

43

Radiation exposure of the population of the GDR by X-ray diagnostics  

International Nuclear Information System (INIS)

The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.

1986-01-01

44

Population doses from beam-therapy in Japan, 1978, 3  

International Nuclear Information System (INIS)

As a series of estimations of population doses and of risk estimates from medical exposures in Japan, the malignancy significant dose (MSD) and the fatal malignant risk from beam therapy were estimated based on a nationwide survey of radiotherapeutic treatments, using a malignancy significant factor and a weighting factor determined from the data on the cancer mortality among the atomic bomb survivors in Nagasaki. The effective dose was defined as a sum of the product of the weighting factor and the organ or tissue doses with respect to the malignant diseases. The organ or tissue doses were determined with ionization chambers placed at the positions of their center in a MixDp-phantom simulated lung tissues by a block of cork, using a telecobalt unit, a conventional X-ray unit and a medical linear accelerator. The organ or tissue doses were ...

1981-01-01

45

Soft X-ray holography of FIB nanostructured Co/Pt multilayers  

International Nuclear Information System (INIS)

Focused Ion Beam (FIB) milling is a powerful tool to produce ordered magnetic nanostructures. However, it is impossible to produce out-of-plane magnetized nanoscale structures from multilayer films by direct FIB writing. Co/Pt multilayers exhibit an out-of-plane easy axis due to strong perpendicular interface anisotropy. The interface contribution is known to be very sensitive to high energy ion irradiation. In case of 30 keV Ga ions it needs less than one ion per 100 surface atoms to destroy the perpendicular interface anisotropy. We demonstrate how this problem can be overcome by milling a Co/Pt multilayer, which has been deposited on a SiN membrane, from the rear side, through the SiN. The effect of the ions is determined as a function of applied dose utilizing the domain structure imaged by soft X-ray holography. When the magnetic material is removed we find only a very narrow range of destruction around the holes in ...

2009-03-22

46

Particle and X-ray damage in pn-CCDs  

Energy Technology Data Exchange (ETDEWEB)

The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.

2000-01-11

47

Kinetic investigations of graft copolymerization of sodium styrene sulfonate onto electron beam irradiated poly(vinylidene fluoride) films  

Energy Technology Data Exchange (ETDEWEB)

Graft copolymerization of sodium styrene sulfonate (SSS) onto electron beam (EB) irradiated poly(vinylidene fluoride) (PVDF) films was investigated to find out a simple preparation process for sulfonic acid proton exchange membranes with respect to monomer concentration, absorbed dose, temperature, film thickness and storage time. The reaction order of the monomer concentration and absorbed dose of grafting was found to be 2.84 and 1.20, respectively. The overall activation energy for graft copolymerization reaction was calculated to be 11.36 kJ/mol. The initial rate of grafting was found to decrease with an increase in the film thickness. The trapped radicals in the irradiated PVDF films remained effective in initiating the reaction without considerable loss in grafting level up to 180 days, when stored under -60 {sup o}C. The presence and distribution of polystyrene sulfonate grafts in the obtained ...

2011-01-15

48

Organ doses and integral doses in X-ray diagnosis of the chest and of the head  

International Nuclear Information System (INIS)

Organ and tissue doses and integral doses in patients due to diagnostic x-ray examinations of the chest and of the head will be presented. These data have been obtained by measuring the dose distributions in man phantoms by LiF-dosimetry. The data will be compared with data obtained by Monte-Carlo calculations. To obtain average organ doses for a special type of examination for the population or for a specified subpopulation in the variation of the exposure, data due to the different techniques used by the different radiologists has to be known. Such data will be presented. The results of the investigation will be discussed in connection with the concept of the 'somatic significant.

1977-04-01

49

X-ray exposure in the teaching of science at junior and senior high schools  

Energy Technology Data Exchange (ETDEWEB)

A significant amount of X-rays were detected as a leakage from some of the Crooke`s tubes which were used in the teaching of science at junior and senior high schools in Japan. We measured the leaked dose of X-rays from the Crooke`s tubes with ionizing chambers, film badges and TLDs. The maximum leaked dose at 5cm distance from those tubes was estimated 143mSv/h. The effective energy of leaked X-rays was 19.3keV. The maximum dose of students exposed during the teaching of science were estimated 0.15mSv per experiment, which exceeded the value recommended in the ICRP publication 36. (author)

1995-10-01

50

Pulse source of electron and X-ray radiations of subnanosecond duration  

International Nuclear Information System (INIS)

The time and dose characteristics of the electron and X-ray radiations of a tube, connected to a subnanosecond mega volt accelerator, are measured. By the pulse of the accelerating voltage of #>=# 600 kV with duration of #approx =# 0.3 ns the tube generates approximately 5 x 10"1"2 electrons pulse. The current amplitude equals approximately 5 kA/pulse and the radiation dose-about 5 kGy/pulse. The X-ray radiation dose from the tantalum external target constitutes 0.15 Gy/pulse. The prototypes of the electron and X-ray tubes sufficiently lower volumes, opening new applications in the technique and medicine, are developed

51

Estimation of X-rays dose in the crystals of final thickness  

International Nuclear Information System (INIS)

A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.

52

The effect of X-radiation on reticuloendothelial system and its treatment with radiodetoxified-endotoxin and trace elements in rats  

International Nuclear Information System (INIS)

A new in vivo method has been developed for the precise observation of RES activity. Both Escherichia coli endotoxin 100 #mu#g/100 g i.v. (LPS) and radiodetoxified endotoxin 100 #mu#g/100 g body weight i.v. (RD-LPS, TOLERIN) increased the granulopectic activity of RES. The RD-LPS was more effective. The preparation containing trace elements also increased the activity of RES. The treatment consisting of the use of both trace elements and RD-LPS proved to be the most effective. The activity of RES was inversely proportional to various doses of X-ray irradiation (7, 8, 9 Gy). Trace elements and RD-LPS even improved the immunity system of animals having deteriorated RES. (N.T.).

53

Exposure accidents outside basic nuclear installations; Les accidents d`exposition en dehors des installations nucleaires de base  

Energy Technology Data Exchange (ETDEWEB)

With the exception of the 1945 Hiroshima and Nagasaki nuclear weapon explosions and the 1986 Tchernobyl reactor accident, most of the radiation accidents concerns the medical and the traditional industrial sectors. The seriousness of the accident is directly function of the absorbed dose. The paper, first, gives the definition of a radiologic accident with its specific criteria and pathological manifestations. Then, some famous historical accidents are reviewed from the discovery of X-rays to recent acute irradiations due to the careless manipulation of radiation sources. From this analysis, three main causes are put forward: the dysfunction of nuclear medicine apparatuses, the victims` lack of training and knowledge of the risks, and the non-identification or the loss of radiation sources. (J.S.). 1 photo.

1996-04-01

54

Radiation 2006. In association with the Polymer Division, Royal Australian Chemical Institute. Incorporating the 21st AINSE Radiation Chemistry Conference and the 18th Radiation Biology Conference, conference handbook  

International Nuclear Information System (INIS)

Full text: The general population is daily exposed to chronic, low doses of ionizing radiation (IR) from both natural and artificial sources. The biological consequences of acute, high dose IR exposure can be readily determined; however, the nature and significance of low dose, low dose-rate IR effects are still the subject of debate. Confounding the issue, are the phenomena collectively referred to as the Radiation-induced Bystander Effect (RIBE). The RIBE describes a collection of in vitro observations that suggest the presence of a soluble, transmissible factor(s) released from irradiated cells that can induce a biological response in un-irradiated cells. The induction, nature and magnitude of the RIBE varies between cell culture systems, radiation sources and end-points measured. Efforts to confirm the presence of the RIBE in vivo have been confined to in ...

2006-01-01

55

The effect of a metal hip prosthesis on the radiation dose in therapeutic photon beam irradiations  

International Nuclear Information System (INIS)

Prostate and cervical cancer patients are often treated with external X-ray beams of bi-lateral incidence. Such treatment may incur some dose effect that cannot be predicted precisely in commercial treatment planning systems (TPS) for patients having undergone total hip replacement. This study performs a Monte Carlo (MC) simulation and an analytical calculation (convolution superposition algorithm which is implemented in ADAC TPS) of a 6 MV, 5x5 cm"2 X-ray beam incident into water with the existence of hip prosthesis, e.g. Ti6Al4V and CoCrMo alloy. The results indicate that ADAC TPS cannot precisely account for the scatter and backscatter radiation that a metal hip prosthesis causes. For percent depth dose (PDD) curves, the maximum underdosage of ADAC TPS up to 5 mm above the interface between dense material and water is 5%, 20% and 27% for PDD_B_o_n_e, PDD_T_i and PDD_C_o, respectively. The ...

2002-07-01

56

Application of imaging plate technology for NDT; Imaging plate gijutsu to sono oyo  

Energy Technology Data Exchange (ETDEWEB)

This paper describes Fuji computed radiography (FCR) of Fuji Film for NDT (non-destructive testing). Imaging plate (IP) is a two-dimensional detector of X-ray, and shows higher photographic sensitivity than X-ray film. The output emission of IP provides a good linear relationship to X-ray intensity in a wide intensity range. When this emission can be digitized, the X-ray intensity can be also digitized. IP is applied to NDT as an inspection using X-ray. FCR provides higher photographic sensitivity than the conventional X-ray film method, which results in one-fifth to one-twentieth of irradiation time. Images with stable density can be obtained independent of the intensity. Since IP has a wide dynamic range, the variation of X-ray intensity of 1:500 can be expressed in a single image by single shot. High density record ...

1998-10-01

57

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two ...

2007-01-01

58

Effect of gamma irradiation on tensile properties of low molecular weight polyethylene samples  

International Nuclear Information System (INIS)

Three high density polyethylene (PE) samples of different origins, with weight average molar masses ranging from 38 to 63 kg mol"-"1 and displaying a semi-ductile behavior with strain at break ?_R values of the order of 100-140%, were gamma irradiated under nitrogen for doses up to 33.3 kGy. Steric exclusion chromatography and rheometry allowed to quantify the crosslink density X. This later reached values ranging from 4.6 to 9.0x10"-"3 mol kg"-"1, i.e. situated below the gelation point. Differential calorimetry, density measurement and small angle X-rays scattering showed the absence of significant changes in the crystalline morphology, especially lamellar dimensions. Tensile testing revealed an unexpected trend towards brittle regime of fracture while yield stress increases significantly at low doses. It appeared that branching disfavors cavitation during yielding, but this effect is not favorable to ...

2011-08-01

59

Development and clinical experience of C-arm type radiosurgery system or three dimensional therapy system  

Energy Technology Data Exchange (ETDEWEB)

Authors developed a C-arm type radiosurgery system of the linear accelerator suitable for stereotactic radiation therapy and a software for arranging 3-dimensional therapy in the system. In this system, the gantry far conical irradiation of 4 MV (0.6-3 Gy/min) and 6 MV (0.9-4.5 Gy/min) X ray or electron beam for the therapy was connected to a newly designed C-arm and was made capable of rotating around either of the axes crossing vertically. With this system, it became unnecessary to move the bed table of the patient for getting suitable distribution of radiation dose. The local accuracy which was measured by the CCD videocamera on the gantry, was within 0.5 mm from the radiation center. The system made it possible to shorten the irradiation time and to improve the local accuracy of irradiating site. The clinical trial was begun from June, 1996. (K.H.)

1996-10-01

60

Somatic radiation risk in X-ray diagnostics  

Energy Technology Data Exchange (ETDEWEB)

The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.

1983-12-01

61

Somatic radiation risk in X-ray diagnostics  

International Nuclear Information System (INIS)

The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).

1983-01-01

62

Photoluminescence, optically stimulated luminescence, and thermoluminescence study of RbMgF3:Eu2+  

International Nuclear Information System (INIS)

Optically stimulated luminescence (OSL) and thermoluminescence are observed in polycrystalline RbMgF3:Eu2+ after x-ray, ?-ray, or ? irradiation. The main electron traps are F-centers but there are other unidentified traps. The main hole traps at room temperature are probably Eu3+ and thermal or optical stimulation leads to electron-hole recombination at the Eu3+ site and Eu2+ emissions arising from 6PJ to 8S7/2 and 4f5d(Eg) to 8S7/2 transitions. We find that some of the electron traps can be emptied by infrared stimulation and all of the electron traps can be emptied by white light stimulation. The OSL dark decay is long and exceeds 5 days for traps that are emptied by white light stimulation after initial infrared bleaching. Our results show that this compound can be used as a radiation dosimeter for intermediate dose levels where the 87Rb self-dose does not significantly affect the ...

2009-01-15

63

Surface modification of PTFE sheet by synchrotron radiation in the soft X-ray region  

International Nuclear Information System (INIS)

Full text: The surface properties of poly (tetrafluoroethylene) (PTFE) are changed by the exposure to synchrotron radiation (SR). We succeeded in controlling the wettability of the PTFE surface from hydrophobic to hydrophilic by varying the substrate temperature during the SR irradiation and found that the wettability was ascribable to microstructure and chemical composition of surface.In these previous works, oxygen atoms were found to inhabit on the hydrophobic surface of PTFE. In this study, we investigated the surface modification of PTFE from the SR exposure experiment under the O_2 gas atmosphere. The SR exposure to the PTFE sheet was carried out at beamline 6 (BL6) of the New- SUBARU. The PTFE sheet was irradiated to the white beam, ranging 50-1000 eV at BL6 at room temperature. The gas cell was mounted at the irradiation chamber. The O_2 gas pressure in the gas cell can be maintained at about 0.20 Pa during the SR ...

2004-07-19

64

A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: comparison of calculated and measured 10-MV X-ray doses in thorax-like phantoms  

British Library Electronic Table of Contents (United Kingdom)

We performed experimental studies on the convolution/superposition method reported in the former companion paper (Iwasaki in Radiol Phys Technol 4, 2011) using 10-MV X-ray beams from open-jaw-collimated fields. The method uses primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. We made a comparison of calculations and measurements in water phantoms and thorax-like phantoms with respect to percentage depth dose curves, tissue???phantom ratio curves, and dose profiles. We made the dose calculation by taking into account the beam-hardening effect with depth and the off-axis radiation-softening effect. We found that the method could be used, in general, for performing accurate dose calculations.

2011-01-01

65

X-ray imaging dose due to the digital imaging devices used in radiation therapy for patient positioning and repositioning: How to take it into account?; Les doses dues a l'imagerie numerique pour le controle de positionnement du patient en radiotherapie: comment les prendre en compte?  

Energy Technology Data Exchange (ETDEWEB)

The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)

2008-12-15

66

Packaging materials for use in radiation processing of foods  

International Nuclear Information System (INIS)

In radiation processing of food, the product often has to be prepackaged to prevent microbial recontamination during and after irradiation. The packaging material is exposed to radiation during radiation processing and radiation stability is a key consideration in the selection of packaging materials. The effects of ionizing radiation on many food packaging materials at the dose levels recommended for food precessing can be minimized by selecting appropriate radiation resistant materials. It is important to select materials in which chemicals formed as a result of the radiation treatment do not migrate and interact with the food, affecting its organoleptic and toxicological aspects. It is also important to select materials in which the physical properties are not altered to the extent they cannot resist damage during commercial production, shipment and storage. Radiation treatment of food may be classified broadly into two categories: 1. ...

67

X-RAY MICROANALYSIS OF A RADIOACTIVE PARTICLE WITH THE AID OF THE ELECTRON MICROSCOPE  

Science.gov (United States)

A radioactive particle was analyzed to discover the composition of the inactive material of the particle. The method uses the x-ray line spectrum of the K series caused by electron irradiation of the particle in the electron microscope. Iron and aluminum or silicon (the last two could not be distinguished) were found as inactive components in the particle. (D.L.C.)

1962-07-28

68

Chemical effects on L_#gamma#_1/L_#beta#_1 x-ray intensity ratio of molybdenum compounds  

International Nuclear Information System (INIS)

Chemical effects on the intensity ratio of LX-ray of molybdenum compounds irradiated by 11-keV electrons and by 3-MeV protons were studied using an x-ray crystal spectrometer. It was found that the intensity ratios of L_#gamma#_1/L_#beta#_1 markedly decrease with the increase of ionicity of molybdenum compounds, except for the case of metallic molybdenum. (author).

1987-06-01

69

Dose, exposure time, and resolution in Serial X-ray Crystallography  

CERN Document Server

The resolution of X-ray diffraction microscopy is limited by the maximum dose that can be delivered prior to sample damage. In the proposed Serial Crystallography method, the damage problem is addressed by distributing the total dose over many identical hydrated macromolecules running continuously in a single-file train across a continuous X-ray beam, and resolution is then limited only by the available molecular and X-ray fluxes and molecular alignment. Orientation of the diffracting molecules is achieved by laser alignment. We evaluate the incident X-ray fluence (energy/area) required to obtain a given resolution from (1) an analytical model, giving the count rate at the maximum scattering angle for a model protein, (2) explicit simulation of diffraction patterns for a GroEL-GroES protein complex, and (3) the frequency cut off of the transfer function ...

2007-01-01

70

On the determination of the dose-area product during X-ray examinations  

International Nuclear Information System (INIS)

Despite its great usefulness in the performance of the recording procedures prescribed by the X-Ray Ordinance the dose-area product is much less frequently measured for X-ray exposures than during fluorscopic examinations. The great multitude of measuring units, mainly on account of different scales of the measuring equipments themselves, is a cause of uncertainty in clinical routine and should be eliminated as far as the circumstances would permit. As the determination of the organ dose is relevant only in very few cases and does not necessarily require previous measurements of the dose-area product, these are of limited practical value in the assessment of individual radiation exposures during radiographic examinations. The measurements may, however, be very helpful in determinations of the radiation dose to the total population, if the future retrievability ...

71

AECL IMPELA electron beam industrial irradiators  

International Nuclear Information System (INIS)

A family of industrial irradiators is being developed by AECL to cover an electron-beam energy range from 5 to 18 MeV at beam powers between 20 and 250 kW. The IMPELA family of irradiators is designed for push button, reliable operation. The major irradiator components are modular, allowing for later upgrades to meet increased demands in either electron or X-ray mode. Interface between the control system, irradiator availability and dose quality assurance is in conformance with the most demanding specifications. The IMPELA irradiators use a klystron-driven, standing-wave, L-band accelerator structure with direct injection from a rugged, triode electron gun. Direct control of the accelerating field during the beam pulse ensures constant output beam energy, independent of beam power. The first member of the family, the IMPELA 10/50 (10 MeV, 50 ...

72

Correlating microstructure and thermal transport of irradiated SiC  

International Nuclear Information System (INIS)

Full text of publication follows: The effect of neutron irradiation on the thermal conductivity of silicon carbide can be dramatic depending on the irradiation temperature and fluence the material is subjected to, and may be a critical factor defining it's use in fusion systems. Historically there have been several papers describing the effect of neutron irradiation on thermal conductivity degradation of SiC, predominately in the low to intermediate temperature ranges. Practically all of this work has been at temperatures lower than the application temperature for SiC being considered by the conceptual fusion reactors. This paper provides new data on the thermal conductivity of high quality CVD silicon carbide irradiated in a range of doses and temperature spanning the proposed fusion reactor temperature range. Specifically, an irradiation was carried out from ...

2007-12-10

73

Evaluation of diagnostic digital radiography of the chest in comparison with conventional chest x-ray films  

International Nuclear Information System (INIS)

Digital radiography for diagnosis of chest diseases using Fuji Computed Radiography (FCR) was evaluated. The results were as follows; 1. Compared to the conventional chest X-ray films, various types of image enhancement could be made by manipulation of the digital information such as tone conversion, spatial frequency modification etc. 2. Digital radiography lessens the X-ray exposure dose and will ultimately permit speedy transmission of image data from outlying clinics to central processing hospitals. 3. Digital radiographic images are useful in chest X-ray diagnosis especially in mass surveys for lung cancer and in primary care medicine because of its full imaging capability. (author).

1983-01-01

74

Patient doses from medical uses of x-rays  

International Nuclear Information System (INIS)

A survey to determine the annual genetically significant dose and mean bone-marrow dose to the Australian population from radiological procedures has been undertaken. For diagnostic radiology the following were carried out: determination of the frequency of a procedure; measurement of patient doses using TLD and processing of data and calculation of gonadal and bone-marrow doses.

1981-01-01

75

Radioadapted chicken embryo cells: challenge specificity and alterations in higher-order DNA structure  

Energy Technology Data Exchange (ETDEWEB)

Radioadapted chicken embryo cells (X-irradiation in ovo with 10 cGy at the 14th day of development with priming periods of 24 h) were treated in vitro by challenge doses of 14 different DNA- and/or chromatin-interactive agents, including X-rays. A decrease in the cellular damage, as measured by scheduled DNA synthesis, was only observed with X-irradiation. Sedimentation of nucleoids as well as viscosity of alkaline lysates from ethidium bromide (0.35-400 {mu}g/ml)-, vovobiocin (125-1800 {mu}g/ml)-, and hyperthermia (30 min at 43 and 45 )-treated cells suggest a higher tendency of radioadapted cells to undergo positive DNA supercoiling. When DNA from adapted and non-adapted chicken embryo cells was used as substrate, neither its digestion by DNase I nor the inhibition of DNase I activity by various DNA-interactive agents was changed in primed cells. From the previous investigations as well as from the ...

1996-03-01

76

Radiation hardening of final optics for an ICF reactor  

International Nuclear Information System (INIS)

Radiation damage of the final optical components in an Inertial Confinement Fusion (ICF) reactor is a crucial issue for development of a laser-fusion reactor. To some extent, this problem will be encountered in the National Ignition Facility (NIF), but there, the integrated radiation dose will be considerably less than that encountered in a future reactor. This extremely harsh radiation environment necessitates shielding the ICF optics from direct neutron and x-ray bombardment. Several approaches have been suggested, such as the use of grazing incidence metal mirrors or fused silica wedge deflectors. While metal mirrors can withstand a larger radiation dose, their focusing qualities pose problems. Therefore wedge deflectors, originally suggested by Lawrence Livermore National Laboratory (LLNL) staff, represent a promising alternative. Radiation hardening of the fused silica deflectors using a new combined thermal/optical ...

1995-04-24

77

X-dosimetry of Tl(InS_2)_1_-_x(FeSe_2)_x single crystals  

International Nuclear Information System (INIS)

Tl(InS_2)_1_-_x(FeSe_2)_x single crystals (where x=0; 0.001; 0.005; 0.01 and 0.015) were grown by the Bridgman-Stockbarger method. Obtained single crystals were crystallized in monoclinic structure. The present paper deals with experimental results relative to X-ray dosimetric characteristics of the Tl(InS_2)_1_-_x(FeSe_2)_x solid solutions at 300 K. Installation URS-55a was the source of radiation. X-ray radiation dose (E) falling on the crystals is measured by the crystalline X-ray dosimeter DRGZ-02. The value of X-ray conductivity coefficient K_#sigma# characterising X-ray sensitivity is defined as K_#sigma#= (#sigma#_E-#sigma#_0)/E#sigma#_0. where #sigma#_E is conductivity under the effect of X-ray radiation by intensity E, #sigma#_0 is conductivity in the lack of radiation. Comparing X-ray dosimetric characteristics ...

2003-09-15

78

Viscosity changes in hyaluronic acid: Irradiation and rheological studies  

Energy Technology Data Exchange (ETDEWEB)

Hyaluronic acid (HA) is a significant component of the extracellular matrix (ECM), particular interest being shown herein in synovial fluid. The present study aims to investigate the degrading effects of X-ray radiation on HA at radiotherapy doses. Measurements of viscosity and shear stresses on HA solutions have been made at different shear rates using various types of viscometer for different concentrations in the range 0.01-1% w/v of HA. The HA has been subjected to doses of 6 MV photon radiation ranging from 0 to 20 Gy, the major emphasis being on doses below 5 Gy. It is found that there is a dose-dependent relationship between viscosity and shear rate, viscosity reducing with radiation dose, this being related to polymer scissions via the action of radiation-induced free radicals. The dependency appears to become weaker at higher concentrations, possibly ...

2010-04-15

79

[Somatic radiation risk in conventional tomography of the skull and thorax].  

Science.gov (United States)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other x-ray examinations, especially computerised tomography. PMID:7134769

1982-10-01

80

Somatic radiation risk in conventional tomography of the skull and thorax  

Energy Technology Data Exchange (ETDEWEB)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography.

1982-10-01

81

Somatic radiation risk in conventional tomography of the skull and thorax  

International Nuclear Information System (INIS)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography. (orig.).

1982-01-01

82

Evidence for a lack of DNA double-strand break repair in human cells exposed to very low x-ray doses  

UK PubMed Central (United Kingdom)

DNA double-strand breaks (DSBs) are generally accepted to be the most biologically significant lesion by which ionizing radiation causes cancer and hereditary disease. However, no information on the...Full Text Available

2003-04-29

83

Total dose hardening of SIMOX buried oxides for fully depleted devices in rad-tolerant applications  

International Nuclear Information System (INIS)

A total dose hardening treatment is applied to SIMOX buried oxides. Total ionizing dose radiation testing is performed on fully-depleted transistors fabricated on both hardened and non-hardened substrates. At 200 krads x-ray dose, the front gate shift is reduced from -0.7 to -0.2 V for FETs built on the hardened wafers.

1996-07-15

84

Radiation exposure of children in pediatric radiology, Pt. 8. Radiation doses during thoracoabdominal babygram and abdominal X-ray examination of the newborn and young infants; Zur Strahlenexposition von Kindern in der paediatrischen Radiologie. T. 8. Strahlendosen beim thorakoabdominalen babygramm und bei der abdomenaufnahme neugeborener und saeuglinge  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction ...

2010-06-15

85

Radiation exposure of children in pediatric radiology, Pt. 8. Radiation doses during thoracoabdominal babygram and abdominal X-ray examination of the newborn and young infants  

International Nuclear Information System (INIS)

Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was ...

2010-06-01

86

Grain boundary transport in x-ray irradiated polycrystalline diamond  

International Nuclear Information System (INIS)

The transport properties of a 'thin' polycrystalline diamond film are analyzed after the sample exposure to 8.06-keV x-ray radiation. Structure and morphology of the as-grown film have been evaluated by Raman, x-ray diffraction, and scanning electron microscopy techniques. The transport properties have been investigated by measuring dark current-voltage characteristics in the temperature range of 60 to 360 K. Ohmic transport has been evidenced on the as-grown film up to 1.16x10"5 V/cm. After irradiation, nonlinear contributions to the dark current have been evidenced and related to field-assisted thermal ionization of traps. Below 200 K, hopping mechanisms have been observed. Correlations have been found among x-ray irradiation, density of traps involved in the transport processes, and the nonhomogeneous nature of the sample. A simple model of the grain boundary structure is ...

2003-05-15

87

Measurement of reactor tube cladding thickness by x-ray fluorescence spectrometry  

International Nuclear Information System (INIS)

An x-ray fluorescence spectrometer was designed and fabricated which nondestructively determines the thickness of aluminum cladding at small suspected thin spots in the inner or outer surface of actinide reactor tubes. The analysis method is based on the difference in absorption of actinide L/sub #alpha#/ and L/sub #beta#/ fluorescent x-rays in passing through the cladding. Calibration plots of the logarithm of the L/sub #beta#//L/sub #alpha#/ x-ray intensity ratio versus cladding thickness are linear to at least 40 mils for U-Al, U_3O_8-Al, and PuO_2-Al substrates. Accuracy and precision of the experimentally determined cladding thickness and evaluated for both uranium and plutonium substrates. Experimental thickness data are reported for 618 quality assurance analyses on six Mark 41 PuO_2-Al target tubes. An x-ray fluorescence cladding thickness monitor operated with a computer-controlled fluoroscope ...

1978-01-01

88

Radiation damage on amorphous metals. [Helium ion, neutron and gamma ray irradiation  

Energy Technology Data Exchange (ETDEWEB)

The structural variations of amorphous metals, such as Pd/sub 80/Si/sub 20/, with irradiation of helium ion, neutron, and gamma ray have been mainly pursued by the method of X-ray diffraction and thermal analysis. It should be noticed that the amorphous metals show a radiation resistance, that is, no remarkable structural changes under helium ion, neutron, and gamma ray irradiation.

1982-04-01

89

Radiation exposure of children in pediatric radiology. Pt. 5. Organ doses in chest radiography; Zur Strahlenexposition von Kindern in der paediatrischen Radiologie. T. 5. Organdosen bei der Roentgenuntersuchung des Thorax  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Reconstruction of organ doses of selected organs and tissues from radiographic settings and exposure data collected during chest X-ray examinations of children of various age groups performed in Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007. Materials and Method: The dosimetric data of all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 119 150 chest radiographs of all age groups. Reconstruction of organ doses in 40 organs and tissues in X-ray examinations of the chest was performed based on the conversion factor concept. Results: The radiation exposure of organs in projection radiography is determined by the exact ...

2009-05-15

90

Radiotherapy for ocular lesions by electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Radiotherapy can be very significant as the treatment for ocular lesions, eyes need to be preserved as properly as possible on their functions and cosmetics. The application of conventional X ray therapy has been gradually abandoned as conventional X ray therapy ceased to be accepted as the general treatment for malignant tumors. Consequently the necessity of electron beam therapy has been rising even as the substituted method for conventional X ray therapy. The department of radiology of Gunma University was obliged to establish a new therapy for ocular lesions, and has been trying electron beam therapy since 1973. It is concluded that electron beam therapy is not at all inferior to conventional X ray therapy as reported above. Basic therapeutic methods for ocular lesions are the following: 1) For epidermoid carcinoma, ...

1981-11-01

91

Epidemiological survey of the effects of low level radiation dose: a comparative assessment  

Energy Technology Data Exchange (ETDEWEB)

This volume presents the collations tables of a six volume comparative epidemiological survey of the effects of low level radiation dose. Data are collated for the effects observed in the following irradiated groups:- Preconception irradiation, intra-uterine irradiation, childhood irradiation, adult irradiation. (UK).

1993-10-01

92

Operation of beam line facilities for real-time x-ray studies at Sector 7 of the advanced photon source. Final Report  

Energy Technology Data Exchange (ETDEWEB)

This Final Report documents the research accomplishments achieved in the first phase of operations of a new Advanced Photon Source beam line (7-ID MHATT-CAT) dedicated to real-time x-ray studies. The period covered by this report covers the establishment of a world-class facility for time-dependent x-ray studies of materials. During this period many new and innovative research programs were initiated at Sector 7 with support of this grant, most notably using a combination of ultrafast lasers and pulsed synchrotron radiation. This work initiated a new frontier of materials research: namely, the study of the dynamics of materials under extreme conditions of high intensity impulsive laser irradiation.

2003-09-10

93

Theoretical considerations for X-ray phase contrast mammography by Thomson source  

Energy Technology Data Exchange (ETDEWEB)

The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase imaging with respect to standard ...

2009-09-01

94

Interaction of x-rays and food pyrolysis products in producing oncogenic transformation in vitro  

International Nuclear Information System (INIS)

In recent years it has become evident from epidemiological and experimental data that a large number of environmental factors, including diet, play a role in modifying the incidence of cancer. Cell culture systems in which oncogenic transformation serves as an end point are powerful tools for evaluating these questions. Using such systems it has been shown recently that pyrolysis products from charred surfaces of broiled meat and fish can transform hamster embryo cells in vitro as well as produce tumors in the animal. Our studies in vitro have demonstrated the oncogenic potential of ionizing radiation in both hamster and human cells and have established in hamster cells the dose response relationship at doses ranging from 1 to 600 rad for x-rays and 0.1 to 150 rad for neutrons. The present work was aimed at evaluating whether there exists a cocarcinogenic interaction between a pyrolysis product and ...

1981-07-01

95

Accelerators for proton and heavy ion radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

The construction of Heavy Ion Medical Accelerator in Chiba (HIMAC) at the National Institute of Radiological Sciences was completed in December 1993. HIMAC consists of an injector linac, two synchrotron rings, a high energy beam transport system and a beam irradiation system. Its accelerator parameters are based on the medical requirement, and helium, carbon, neon, silicon and argon were selected as the accelerated ion species. It has 3 therapy rooms (A{approx}C). Room A has a vertical irradiation system, Room C horizontal and Room B both vertical and horizontal. Two rings can supply beams independently to the vertical and horizontal irradiation systems. Clinical trial started on June 21 1994, after several basic biological and physics experiments lasting about 2 months. Cancer is the top cause of death in Japan since 1981, and people expect good treatment results at HIMAC. Proton and heavy ion radiotherapy has the ...

1995-03-01

96

Use of X-ray fluorescence analysis in the study of archeological samples  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis (XFA) was used in the determination of the contents of metal residues in dosing plates for coin minting. XFA was also used for the determination of the strontium/calcium ratio in bone samples of different animals with the aim to obtain information on the food composition of these animals. It was found that bones of different animals can be distinguished based on the Sr/Ca ratio. No significant differences in the Sr/Ca ratio were observed in human bones of individuals from different social groups. (author). 1 fig., 5 tabs., 4 refs.

1988-09-26

97

Tolerance limits of X-ray image intensity  

International Nuclear Information System (INIS)

Evaluation of the tolerance limits of X-ray image density accepted by the radiologist shows that for different kinds of examinations, deviations of more than 50% from optimal density lead to images which cannot be used diagnostically. Within this range diagnostic accuracy shows a distinct maximum and diminishes to the limits by 20%. These figures are related to differences in the intensifying factor of screens, sensitivity of films, sensitometric parameters of film processing as well as the doses employed with automatic exposure control devices, measured in clinical conditions. Maximum permissible tolerance limits of the whole imaging system and of its constituents are discussed using the Gaussian law of error addition. (author).

99

Stochastic risk estimation from medical x-ray diagnostic examinations, 2  

International Nuclear Information System (INIS)

The risks of genetic, leukemia and malignant diseases from medical X-ray diagnostic examinations were estimated using the frequency of radiographic and fluoroscopic exposures per diagnostic examination, child expectancy, leukemia and malignancy significant factors, and using a weighting factor determined on the basis of data concerning the cancer mortality among atomic bomb survivors in Nagasaki and of a recommendation of International Commission of Radiological Protection. The organ or tissue doses with respect to the stochastic risks were determined with ionization chambers and thermoluminescent dosimeters placed at the positions of the organs or tissues in a RANDO woman phantom which was exposed to diagnostic X-rays according to technical factors of typical radiographic and fluoroscopic examinations obtained from a nationwide survey. The resultant risks by age-group and type of radiographic and fluoroscopic examination ...

1981-01-01

100

Optimizing radiotherapy of orbital and paraorbital tumors: intensity-modulated X-ray beams vs. intensity-modulated proton beams  

International Nuclear Information System (INIS)

Purpose: This study presents a dosimetric optimization effort aiming to compare intensity-modulated (IM) X-rays and IM protons in 4 different orbital and paraorbital tumors. These are most challenging targets for standard radiotherapy due to their close relationship with the eyes and related structures. Methods and Materials: A primary orbital lymphoma, an optic nerve meningioma, a sphenoidal ridge meningioma protruding into the orbit, and a pediatric parameningeal paraorbital rhabdomyosarcoma were selected for the purpose of this study. Planning target volumes (PTVs) and organs at risk (OAR) were defined in each patient CT data set for each tumor site. IM X-ray and IM proton three-dimensional treatment plans were implemented. The following total tumor doses were prescribed: 30 Gy for the orbital lymphoma, 54 Gy for both meningiomas, and 50.4 Gy for the rhabdomyosarcoma case. Dose-volume histograms ...

2000-07-01

101

Study of the lattice parameter evolution of PWR irradiated MOX fuel by X-Ray diffraction; Etude de l'evolution du parametre cristallin des combustibles MOX irradies en rep par la methode de diffraction des rayons X  

Energy Technology Data Exchange (ETDEWEB)

Fuel irradiation leads to a swelling resulting from the formation of gaseous (Kr, Xe) or solid fission products which are found either in solution or as solid inclusions in the matrix. This phenomena has to be evaluated to be taken into account in fuel cladding Interaction. Fuel swelling was studied as a function of burn up by measuring the corresponding cell constant evolution by X-Ray diffraction. This study was realized on Mixed Oxide Fuels (MOX) irradiated in a Pressurized Water Reactor (PWR) at different burn-up for 3 initial Pu contents. Lattice parameter evolutions were followed as a function of burn-up for the irradiated fuel with and without an annealing thermal treatment. These experimental evolutions are compared to the theoretical evolutions calculated from the hard sphere model, using the fission product concentrations determined by the APPOLO computer code. Contribution of varying ...

1995-07-01

102

28: Calculation of 3D dose distribution for photons in inhomogeneous media  

International Nuclear Information System (INIS)

A method for calculation of absorbed dose distributions in three dimensions for 1-20 MeV photons is presented. The method uses convolution/superposition of photon fluence distributions with energy scattering kernels. Results for Co-60 and X-ray beams in homogeneous and inhomogeneous media are compared with measurements. Good agreement is found between calculations and measurements. 8 refs.; 3 figs.

103

Quality control in medical radiology using T.L.D  

Energy Technology Data Exchange (ETDEWEB)

In this work tests of quality control in beams of X rays have been carried out, at diagnostic level, of two radiological services equipments of Brazilian hospitals (Aracaju, SE). We obtained the air kerma and kerma rate values, the beams efficiency, the coherence between the luminous fields and the referring fields of irradiation and half-value layer to each equipment and set of parameters. The measures of direct form have been obtained using two ionization chambers, one cylindrical and another one with parallel plates. An optional method for accomplishment some of the tests were carried out with CaSO{sub 4}:Dy + Teflon thermoluminescent dosimeters. The values of air kerma were evaluated for three tube voltage, 40, 60 and 81 kV at 1.0 m from the focus of the equipments. For each one of the voltages three distinct current values were chosen besides a fixed value of exposition time. The results showed that the values of air ...

2006-07-01

104

Projection techniques in diagnostic radiography discussed with regard to required dose  

International Nuclear Information System (INIS)

The paper presents information in the form of data, tables and diagrams compiled to a broad but very up-to-date survey of required radiation for the various most frequently performed X-ray examinations of patients. The required dose is discussed from the point of view of radiation protection, defining the inevitably administered dose to the skin, the frequency of examinations, and the diagnostic image quality as the main three factors to be observed, as these determine the radiation dose to the patient and to the personnel. The somatic risks of radiography examinations are a point of main interest. (DG).

1990-09-01

105

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

Energy Technology Data Exchange (ETDEWEB)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-08-01

106

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

International Nuclear Information System (INIS)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-01-01

107

Determination of absorbed dose in a patient irradiated by beams of x or gamma rays in radiotherapy procedures  

CERN Document Server

Determination of absorbed dose in a patient irradiated by beams of x or gamma rays in radiotherapy procedures

1976-01-01

108

Evaluation of transient dose in conveyor type low dose irradiator  

International Nuclear Information System (INIS)

In conveyor type irradiators, the movement of conveyor and the product boxes is not there until the source is fully in the irradiation position. In case the conveyor system fails the source must automatically be returned to its shielded storage vault. The dose received by the product during the movement of the source from or to the shield becomes significant if the total dose to be received by the product is small. A study has been carried out for evaluating the transient dose received by onions in the POTON irradiator. The results of the study are discussed in this paper. (author)

2003-03-05

109

Hyaluronic acid production by irradiated human synovial fibroblasts  

International Nuclear Information System (INIS)

Radioactive particles as well as x irradiation from an external source has been used in the treatment of rheumatoid arthritis, osteoarthritis, and ankylosing spondylitis. In order to clarify effects of ionizing irradiation on synovial cells, radioactive gold ("1"9"8Au) and yttrium ("9"0Y) were added to fibroblast cultures derived from human synovial membranes. Other cultures were irradiated by a Picker x-ray machine. Fibroblast growth and hyaluronic acid production were measured. Radioactive gold and yttrium particles induced a significant increase of hyaluronic acid synthesis rate (pg/cell/day) and inhibited fibroblast growth. Fibroblasts continued to overproduce hyaluronic acid and to show growth inhibition 3 weeks after irradiation with radioactive gold. Hydrocortisone inhibited hyaluronic acid overproduction induced by radioactive gold. Overproduction of hyaluronic acid induced ...

1977-01-01

110

Energy Dispersive X-ray Analysis in the Electron Microscope  

CERN Document Server

Energy Dispersive X-ray Analysis in the Electron Microscope

2003-01-01

111

ASE FILE  

Science.gov (United States)

radionuclide X-ray fluorescence analysis: the resolving power of the ... The radiation detectors used in radionuclide X-ray fluorescence ...

112

Some physical considerations in whole skin electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

The short range of low-energy electrons has made them suitable for the treatment of skin lesions, especially when extensive areas must be irradiated with special considerations to save the normal underlying tissue. This report covers some salient features of total body electron irradiation: the construction of the large fields required, x-ray contamination levels, and multiple-field techniques. While the investigation is essentially experimental, we also indicate the results of calculations. We conclude most generally that treatment planning with whole skin irradiations can be as precise as with smaller fields.

1982-09-01

113

Anomaliously high radiation hardening of iron-chromium alloys  

International Nuclear Information System (INIS)

Argon ions irradiation of 12% Cr steels and Fe/Cr alloys results in the hardening up to 10000 MPa. This value exceeds the hardening level even for martensitic transformation. Along with the increase of microhardness following irradiation the shape of X-ray graph of the affected materials changes considerable. Hardening value and behavior are determined by temperature radiation doze, preliminary ageing, extent of cold strain and alloying. The odserved phenomenon is supposed to be caused by irradiation-induced structural transformations. Reversibility of radiation hardening of the materials in question was observed.

114

Measurements of x-ray radiation dose levels during radiological examination in Jos university teaching hospital and Plateau state specialist hospital  

International Nuclear Information System (INIS)

In this project, measurement of x-ray radiation dose level during radiological examination in Jos university teaching hospital and Plateau State specialist hospital at different locations within the department were carried out using radiation survey meter. The results were converted from micro sievert per hour (#mu#Sv/hr) to milisievert per year (mSv/yr). The radiation levels from the two hospitals visited ranged from 1.3m Sv/yr to 8.4m Sv/yr. This implies that all the radiology departments visited are still operating within the safety limit having less than 20 mSv/yr which is the standard permissible radiation level recommended per year.

2008-10-15

115

Gamma irradiation induced damage creation on the cation distribution, structural and magnetic properties in Ni-Zn ferrite  

International Nuclear Information System (INIS)

Ferrite of system, namely Ni_1_-_xZn_xFe_2O_4 with x = (0.0, 0.2, 0.4, 0.6, 0.8, 1.0), have been prepared by solid state reaction to investigate the effect of gamma rays irradiations using Co"6"0 source on the cation distribution, structural and magnetic properties. The unirradiated and irradiated samples were then subjected to characterization techniques such as X-ray diffraction, magnetization and AC susceptibility. The results of these characterizations are found to be different for irradiated from that of the pristine sample. The modifications in respect of irradiated samples are explained in terms of the ion-induced disorder. The important result of #gamma#-irradiation on the cation distribution, structural and magnetic properties is the change of ratio Fe"2"+/Fe"3"+. Possible reasons on the results are proposed.

2010-09-01

116

Study of X-ray filter and peak kilovoltage in Fuji computed radiography in regard to the detection of simulated pulmonary nodules  

Energy Technology Data Exchange (ETDEWEB)

To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that (1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; (2) approximately equal detection rates were obtained for the three ...

1994-10-01

117

Study of X-ray filter and peak kilovoltage in Fuji computed radiography in regard to the detection of simulated pulmonary nodules  

International Nuclear Information System (INIS)

To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that 1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; 2) approximately equal detection rates were obtained for the three ...

1994-01-01

118

Analysis on Dose Distribution in Heterogeneous Condition for Narrow 6 MV X-ray Beams  

International Nuclear Information System (INIS)

Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous condition since the GAFCHROMICat..EBT ...

2010-10-01

119

Monitoring of DNA and cytogenetic damage in lymphocytes from persons with skin cancer diseases  

International Nuclear Information System (INIS)

There is a lot of interest in the studies that would help to understand whether there is a casual association between cancer and various types of molecular or cytogenetic damage detected in human cells. One major oncogenesis process is activation of proto-oncogenes by point mutations or chromosomal translocation. There are substantial evidence that indicates that the loss of heterozygosity of certain chromosomes is involved in human cancerogenesis. Our study aimed to elicit the possible association between cancer and DNA and cytogenetic abnormalities induced in lymphocytes of people bearing various categories of skin cancer cells. Fresh blood was collected by venipuncture from 25 individuals (including nine prior to cancer treatment). All patients were nonsmoking males, however 42.3 % of them were former smokers. Blood samples were divided into two parts and in the first part of samples cytogenetic studies were performed immediately, while from the second part lymphocytes were isolated ...

2004-11-01

120

Construction of a homogeneous phantom for radiographic image standardization; Construcao de um fantoma homogeneo para padronizacao de imagens radiograficas  

Energy Technology Data Exchange (ETDEWEB)

The principle of radiodiagnosis consists in the fact the X-ray beam is attenuated at different degrees by distinct tissues. For this reason, the anatomical structures have distinct radiological opacities, that produce the radiographic image. The progresses in radiology are related to the development if new radiographic image formation systems that enable an amplification in the quality, with low dose and/or risk to the patient. The objective of this work is the sensitometric valuation of a screen-film combination, that is still the most used, for the standardization, of radiographic images. Thinking about this, were constructed homogeneous phantoms of the chest, skull and pelvis, for the calibration of X-ray beams, with the purpose of obtaining radiographic images of good quality, basing in the routine of a radiodiagnosis service and in the scientific knowledge. Questions were approached about the choice of the suitable ...

1996-12-31

121

Comparison of two dose-area-product ionization chambers with different conductive surface coating for over-table and under-table tube configurations  

Energy Technology Data Exchange (ETDEWEB)

A custom-built graphite-coated transmission ionization chamber is compared to the VacuDAP 2001 (VacuTec, Dresden, Germany), which has transparent conductive electrodes. A study was made of the dependence of response on x-ray tube potential for both types of chamber under identical conditions of exposure using over-table and under-table x-ray tubes. Since the calibration factor is the dose-area product of the radiation incident on the patient per chamber reading, it depends on the intrinsic response of the chamber as well as the effect of material in the beam between the x-ray tube and patient. Differences of about 20% were measured between the intrinsic and the over-table calibration factors and between the over-table and the under-table calibration factors for both chambers. The VacuDAP display is specifically calibrated for the over-table condition and would overstate the actual DAP in the under-table ...

2000-03-01

122

Optimizing the radiosensitive liquid-core microcapsules for the targeting of chemotherapeutic agents  

Energy Technology Data Exchange (ETDEWEB)

Microcapsules consisting of alginate and hyaluronic acid that can be decomposed by radiation are currently under development. In this study, the composition of the microcapsule material was optimized by changing the amounts of alginate and hyaluronic acid. Solutions of 0.025%, 0.05%, 0.1%, 0.2%, or 0.4% (wt./vol.) hyaluronic acid were mixed into a 0.2% alginate solution. To these mixtures, carboplatin (0.2 mmol) was added and the resulting material was used for the capsule preparation. The capsules were prepared by spraying the material into a CaCl{sub 2} solution (0.34 mol/l) using a microatomizer. These capsules were irradiated by a single dose of 2, 5, or 10 Gy {sup 60}Co {gamma}-ray radiation. Immediately after irradiation, the releasing of core content of microcapsule was determined, using a micro particle induced X-ray emission (PIXE) camera. The average diameter of the microcapsules was 22.3 {+-} ...

2007-07-15

123

Statistical cut-off criterion  

International Nuclear Information System (INIS)

... radiation effects human populations low dose irradiation neoplasms radiation

1980-01-01

124

Some comments on BEIR III  

International Nuclear Information System (INIS)

... organizations irradiation radiation doses radiation effects RADIATIONS.

1982-01-01

125

Influencing factors on ESR dose assessment in irradiated chicken legs  

Energy Technology Data Exchange (ETDEWEB)

Electron spin resonance (ESR) dosimetry of irradiated chicken legs is based on the additive dose or the calibration curve methods. In both cases the practical assumption is made that the behaviour of the chicken bone does not depend on factors such as temperature during irradiation, storage conditions and dose rate. So the aim of the present work was to investigate to what extent the above mentioned factors could influence the post-irradiation dose assessment using the ESR technique. (author).

1996-12-31

127

Some optimization measurements and parameters of a radionuclide X-ray fluorescence spectrometer  

International Nuclear Information System (INIS)

An irradiation head with sample holders is described and measurement geometry is reported. Measurements were made for optimizing the distance between the source and the sample and for optimizing the sample diameter. The optimal distance between the source and the sample does not depend on the collimator diameter. The sample diameter should not exceed 30 - 35 mm. Sensitivity and detection limits were determined for Zn, Pb and Br and calibration curves were plotted. (M.D.) 6 figs., 2 tabs., 4 refs.

1986-01-01

128

PIXE analysis of trace elements in relation to chlorophyll concentration in Plantago ovata Forsk  

Energy Technology Data Exchange (ETDEWEB)

Plantago ovata Forsk - an economically important medicinal plant - was analyzed for trace elements and chlorophyll in a study of the effects of gamma radiation on physiological responses of the seedlings. Proton-induced X-ray emission (PIXE) technique was used to quantify trace elements in unirradiated and gamma-irradiated plants at the seedling stage. The experiments revealed radiation-induced changes in the trace element and chlorophyll concentrations.

2010-03-15

129

Analysis of TL glow curves in differently doped LiF:Mg,Ti  

International Nuclear Information System (INIS)

A computerised curve-fitting method was developed to calculate the trapping parameters in LiF TLD-100 and LiF:Mg, Ti. After irradiation in a "6"0Co field and with X rays emitted at different voltages the TL process is best described by first-order kinetics. A dependence of the trapping parameters on both the concentration of Mg and Ti and photon energy was detected. (author).

130

Stochastic risk estimate for barium radiological examinations in Malaga (Spain)  

International Nuclear Information System (INIS)

The aim of this research work has been the estimation of the stochastic risk for five barium examinations. The sample was the population attending the Radiological Service of the 'Nuestra Senora de la Victoria' University Hospital, who had been treated with some barium examinations, set in five different groups: oesophagus tract, oesophagus-gastric-duodenal tract, intestinal tract, enteroclysis and double enema. To estimate the stochastic risk, it is necessary to know the organ dose. This can be calculated from the dose-area product which allows us to determine the effective dose using software. The dose-area product is the most suitable quantity to measure in these types of examination. We have evaluated the contribution that each procedure provides to the genetically significant dose, somatically significant dose, collective effective ...

2000-01-01

131

Stochastic risk estimation from medical x-ray diagnostic examinations, 3  

International Nuclear Information System (INIS)

The genetically significant dose (GSD), per Caput mean bone marrow dose (CMD), leukemia significant dose (LSD) and malignancy significant dose (MSD) from medical diagnostic X-ray examinations in Japan were estimated based on a 1979 nationwide survey of randomly sampled hospitals and clinics. The population risk estimates were carried out using the resultant values of GSD, LSD and MSD. In the risk estimates, the significant factors, namely, the relative child expectancy, the leukemia significant factor and the malignancy significant factor, for patients were assumed to be same as those of general population. The risk factors used were 185 x 10"-"6 rad"-"1 for genetic risk of all generations, 20 x 10"-"6 rad"-"1 for fatal leukemia and 165 x 10"-"6 rad"-"1 for fatal malignant diseases, respectively. The resultant annual population doses per person were 15 mrad ...

132

Sources of X-rays in school; Zrodla promieniowania rentgenowskiego w szkole  

Energy Technology Data Exchange (ETDEWEB)

Exposure of teachers of physics to X-radiation emitted by instruments which are used for demonstrating rarefied gas discharges during physics lessons at secondary schools is discussed. The measurements performed provide an explicit evidence that an effective, annual exposure dose under the most unfavorable conditions does not exceed admissible levels according to Polish regulations pertaining to persons non-occupationally exposed to ionizing radiation. (author). 3 refs,1 fig.

1996-12-31

133

Reference values for X-ray diagnostic investigations. Some thoughts on the relation between expenditure and benefit  

International Nuclear Information System (INIS)

In the first part of this contribution, the definition of reference values is given and the theoretical and practical problems in the application of this concept are discussed. In this connection, the present resources on instrumentation and the technical requirements for dose assessment are described. In the second part, some consequences are taken and proposals for further actions are made. (orig.)

134

Piperazine sulfonamide BACE1 inhibitors: Design, synthesis, and in vivo characterization  

British Library Electronic Table of Contents (United Kingdom)

With collaboration between chemistry, X-ray crystallography, and molecular modeling, we designed and synthesized a series of novel piperazine sulfonamide BACE1 inhibitors. Iterative exploration of the non-prime side and S2prime sub-pocket of the enzyme culminated in identification of an analog that potently lowers peripheral Ab40 in transgenic mice with a single subcutaneous dose.

2010-01-01

135

Methods and results of a representative analysis of the radiation exposure of the population by diagnostic radiology  

International Nuclear Information System (INIS)

From the frequency of diagnostic radiologic examinations and their radiation dose delivered to the population the risk of cancer induction and genetic damage is calculated on the basis of the risk factors given by the ICRP. Thus 0.38 % and 3 % of the total mortality for cancer and leukemia, resp., can be attributed to X-ray diagnostics. Chest examinations alone result in 0.07-0.7 damages per 100,000 persons depending on the imaging technique applied. (author).

1984-01-01

136

Lung studies with spiral CT. pitch 1 versus pitch 2  

International Nuclear Information System (INIS)

In Spiral CT, the pitch is the ratio of the distance to tabletop travels per 360 degrees rotation to nominal slice width, expressed in mm. Performing Spiral CT examination with pitch 2 allows to reduce examination time, exposure and contrast dose, and X-ray tube overload. The authors investigated the yield of pitch 2 in lung parenchyma studies, particular relative to diagnostic image quality.

1999-03-01

137

Depth-profiling of vertical sidewall nanolayers on structured wafers by grazing incidence X-ray flourescence  

British Library Electronic Table of Contents (United Kingdom)

The Physikalisch-Technische Bundesanstalt (PTB), Germany's national metrology institute, developed an alignment strategy to specify elemental depth profiling in vertical sidewall layers on structured wafers. For this purpose, PTB's irradiation chamber for 200?mm and 300?mm silicon wafers was used to combine total-reflection X-ray fluorescence (TXRF) and grazing incidence XRF (GIXRF) techniques by employing monochromatized undulator radiation of the BESSY II electron storage ring. 3-D test structures were fabricated to develop an optimal alignment strategy allowing for depth profiling in such nanolayers. The test structures consisted of silicon bars with widths/spacings either in the ?m or in the nm range. In order to be able to differentiate the sidewalls more easily from the remainder of ...

2008-01-01

138

Lung dose calculations at kilovoltage x-ray energies using a model-based treatment planning system  

International Nuclear Information System (INIS)

The determination of the dose to organs from diagnostic x rays has become important because of reports of radiation injury to patients from fluoroscopically guided interventional procedures. We have modified a convolution/superposition-based treatment planning system to compute the dose distribution for kilovoltage beams. We computed lung doses using this system and compared them to those calculated using the CDI3 organ dose calculation program. We also computed average lung doses from a simulated radiofrequency ablation procedure and compared our results to published doses for a similar procedure. Doses calculated using this system were an average of 20% lower for AP beams and 7% higher for PA beams than those obtained using CDI3. The ratio of the average dose to the lungs to ...

2001-02-01

139

Radioprotective activity in some medicinal herbs  

Energy Technology Data Exchange (ETDEWEB)

Water-soluble, ethanol-insoluble extracts prepared from several medicinal herbs of the Araliaceae and other families were tested for their radioprotective activity by either measuring 30 days survival rates (a commonly applied method) or counting the thrombocytes 14 days after irradiation (an improved method) in mice. The extracts were i.p. injected once within 4 min after the whole body X-ray irradiation. Of 12 materials examined, Aralia elata, Angelica acutiloba and Morus bombysis seemed to be good starting materials for preparing radioprotective substance(s) because of their relatively high specific activity and high yields of the extracts. (author).

1993-09-01

140

High Exposure Facility Technical Description  

Energy Technology Data Exchange (ETDEWEB)

The High Exposure Facility is a collimated high-level gamma irradiator that is located in the basement of the 318 building. It was custom developed by PNNL back in 1982 to meet the needs for high range radiological instrument calibrations and dosimeter irradiations. At the time no commercially available product existed that could create exposure rates up to 20,000 R/h. This document is intended to pass on the design criteria that was employed to create this unique facility, while maintaining compliance with ANSI N543-1974, "General Safety Standard for Installations Using Non-Medical X-Ray and Sealed Gamma-Ray Sources, Energies up to 10 MeV."

2008-02-12

141

PET/MRI hybrid imaging: devices and initial results  

British Library Electronic Table of Contents (United Kingdom)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...

2008-01-01

142

Non-destructive Imaging of Individual Bio-Molecules  

CERN Document Server

Radiation damage is considered to be the major problem that still prevents imaging an individual biological molecule for structural analysis. So far, all known mapping techniques using sufficient short wave-length radiation, be it X-rays or high energy electrons, circumvent this problem by averaging over many molecules. Averaging, however, leaves conformational details uncovered. Even the anticipated use of ultra-short but extremely bright X-ray bursts of a Free Electron Laser shall afford averaging over 10^6 molecules to arrive at atomic resolution. Here we present direct experimental evidence for non-destructive imaging of individual DNA molecules. In fact, we show that DNA withstands coherent low energy electron radiation with deBroglie wavelength in the Angstrom regime despite a vast dose of 10^8 electrons/nm^2 accumulated over more than one hour.

2009-01-01

143

Evolution of surface roughness in silicon X-ray mirrors exposed to a low-energy ion beam  

International Nuclear Information System (INIS)

The possibility of smoothening aspherical X-ray mirrors by irradiation of the surface with a low-energy ion beam is investigated. Nanofocusing being the primary application of these mirrors the ion beam conditions must be optimized to achieve a surface roughness of the order of 0.1-0.2 nm. To address this issue a first study was performed on silicon flat substrates etched using ion energies ranging from 400 to 1200 eV. A second study consisted of eroding the silicon surface while varying the ion grazing incidence angle between 10 deg. and 90 deg. for a fixed value of the ion energy. The surface topography of the samples was characterized at various scales using atomic force microscopy (probed area: 1-10 ?m2), interferential optical microscopy (probed area: 1 mm2) and X-ray scattering (probed area: 100 mm2). Finally, a study by AFM of the evolution of the surface finish level of a silicon mirror after ion erosion at various ...

2010-05-01

144

Estimated fetal radiation dose from multislice CT studies  

International Nuclear Information System (INIS)

It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.

145

X-Ray Fluorescence Analysis of Composite Propellants for ...  

Science.gov (United States)

... The constancy of the X-ray intensity ratio for each element in Table 8 as the X-ray tube settings were changed shows the excellent compensating ...

1977-06-03

146

Radionuclide X-ray fluorescence analysis. 1: Excitation of X-ray fluorescense radiation by nuclear radiation  

Science.gov (United States)

The principles of radionuclide excitation of X-ray fluorescence radiation and its application in

1972-01-01

147

Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation  

Science.gov (United States)

This investigation describes the technique for the detection of the X-ray fluorescent radiation

1972-01-01

148

The dependence of photovoltage of the system APhV-films photoresistor on the capacity of X-ray radiation dose  

International Nuclear Information System (INIS)

Full text: As you know, thin films which generate anomalous big photovoltage (APhV) , as film photo resistive structures made of the combinations of A_2B_6 respond to X-ray and #gamma#- radiations. In this work the influence of X-ray and #gamma#-radiations on the quantity of APhV in the system APhV-film-photoresistor was investigated. Earlier polycrystal films with anomalous photo voltage properties were received only on the clean and flat surface with high isolation property (R>10"1"4 #OMEGA#). We worked out the technology of receiving APhV films CdTe on the surface of the photosensitive film CdS. The main condition under which this effect may be observed is that the lining must be slant concerning to the direction of the motion of evaporated substance's molecular bunch during the growing of the film, i.e. received film must have a dendritic structure. That is why photosensitive film CdS was received with thermo vacuum slanting ...

2004-08-23

149

Dosimetric properties of an applicator system for intraoperative electron-beam therapy utilizing a Clinac--18 accelerator  

International Nuclear Information System (INIS)

A prototype electron applicator system providing circular and rectangular fields for use in intraoperative electron beam therapy with a Varian Clinac 18 linear accelerator has been fabricated. The dosimetric properties of this system for a variety of electron-beam energies, applicator sizes, and x-ray collimator settings was documented. Significant findings include: (a) surface dose values are in excess of 90% for electron energies of 12 MeV and above; (b) for the 18-MeV beam, the deepest depth where the central axis dose is 90% of its maximum value is in excess of 50 mm for circular applicators whose diameters are in excess of 5 cm; and (c) the treatment time to deliver 1000 rads ''given dose'' (at a given dose rate of 300 MU/min) is on the order of 3--4 min. Cross-field behavior is acceptable for the intended application and x-ray contamination is less than 4% ...

150

Suppression of pitting corrosion with passive film modification on type 304 stainless steel by ultra-violet light irradiation; Shigaikoshosha ni yoru Type 304 stainless ko no fudotai himaku kaishitsu to koshoku yokusei  

Energy Technology Data Exchange (ETDEWEB)

In this study, the effects of 325nm wavelength ultraviolet light irradiation on pitting corrosion behavior of type 340 stainless steel in a neutral chloride solution are studied. Further, the change of passive film with the light irradiation is analyzed using x-ray photoelectron spectroscopy. The mains results obtained therefrom are stated below. Pitting potential can be shifted in noble direction by the ultraviolet light irradiation. The effect of ultraviolet light irradiation is ore prominent in the pitting corrosion process than that in the passive film formation. The result of the analysis in terms of the birth and death stochastic probability process shows that pitting corrosion rate is decreased remarkably by the ultraviolet light irradiation at the formation of passive film, while the repassivation is slightly expedited by the ultraviolet light ...

1998-06-20

151

The effects of chemicals in the presence of cellophane on X-ray-induced point mutation and gene conversion in Aspergillus midulans  

International Nuclear Information System (INIS)

The presence of washed or unwashed cellophane alone or together with a bleomycin, mitomycin C or hydrochlorothiazide, ('Esidrex') showed no appreciable effect on survival of either unirradiated or irradiated conidia. Irradiation for a period of 20min reduced the survival of conidia to 20%. The growth of irradiated conidia in the presence of bleomycin, mitomycin C or Esidrex is associated with a 2- to 3-fold increase in the frequency of gene convertants, but was not accompanied by an increase in point mutants. When conidia were grown on cellophane but otherwise treated as before the frequency of gene convertants was increased 8-fold, but induction of point mutants was negligible. This effect was the same for irradiated and unirradiated conidia. The environment created by the cellophane in contract with the medium appears to affect the action of each of the three compounds synergistically. (author).

152

Structural changes in amorphous Pd/sub 80/Si/sub 20/ by neutron irradiation  

Science.gov (United States)

Amorphous Pd/sub 80/Si/sub 20/ was irradiated with fast neutrons (>1 MeV) to a fluence of 5 x 10/sup 20/ neutrons/cm/sup 2/. X-ray scattering intensities were measured before and after the irradiation with monochromatic Cu-K..cap alpha../sub 1/ rays. Scattered intensities for s>0.4 A/sup -1/ (s=2 sintheta/lambda) proved unaffected, while intensities were found remarkably enhanced for s<0.4 A/sup -1/ after the irradiation, i.e., in the small-angle region and the leading edge of the first halo. The results are discussed in relation to the structural anomalies in amorphous solids.

1977-10-01

153

Effects of chemicals in the presence of cellophane on X-ray-induced point mutation and gene conversion in Aspergillus midulans  

Energy Technology Data Exchange (ETDEWEB)

The presence of washed or unwashed cellophane alone or together with a bleomycin, mitomycin C or hydrochlorothiazide, ('Esidrex') showed no appreciable effect on survival of either unirradiated or irradiated conidia. Irradiation for a period of 20min reduced the survival of conidia to 20%. The growth of irradiated conidia in the presence of bleomycin, mitomycin C or Esidrex is associated with a 2- to 3-fold increase in the frequency of gene convertants, but was not accompanied by an increase in point mutants. When conidia were grown on cellophane but otherwise treated as before the frequency of gene convertants was increased 8-fold, but induction of point mutants was negligible. This effect was the same for irradiated and unirradiated conidia. The environment created by the cellophane in contract with the medium appears to affect the action of each of the three compounds ...

1984-08-01

154

An evaluation of low-dose single-slice helical CT in pulmonary CT scan  

International Nuclear Information System (INIS)

Objective: To investigate the feasibility of low-dose single-slice helical CT in pulmonary CT scan and evaluate the clinical application. Methods: Thirteen cases were selected out of 132 cases, in which low-dose (50mAs) single-slice helical CT scan of chest was performed. This set of cases included 7 cases of multiple metastatic nodules; 3 of solitary pulmonary, nodule; and 3 of pulmonary patchy lesions. Regular dose (170mAs) CT scan was also performed on all those patients. The regular dose and low dose CT scan were compared on sensitivity of detecting the lesions; the performance in demonstrating the details of the abnormalities; and the capability of revealing the segmental bronchi as well. Results: The same number and size of the pulmonary nodules were revealed with scan modalities loaded with different doses. No significant difference in demonstrating the ...

2006-04-01

155

Semi-empirical simulation of thermoluminescent response under different filter geometries; Simulacao semi-empirica da resposta termoluminescente sob diferentes geometrias de filtro  

Energy Technology Data Exchange (ETDEWEB)

Many thermoluminescent materials has been developed and used for photon personal dosimetry but no one has all desired characteristics alone. These characteristics include robustness, high sensitivity, energy photon independence, large range of photon energy detection, good reproducibility, small fading and simple glow curve with peaks above 150 deg C. Calcium Sulfate Dysprosium doped (CaSO{sub 4}:Dy) phosphor Thermoluminescent Dosimeter (TLD) has been used by many laboratories, mainly in Brazil and India. Another interesting phosphor is Calcium Fluoride (CaF{sub 2}). These phosphor advantages begin to be more required and its disadvantages have became more apparent, in a global market more and more competitive. These phosphors are used in environmental and area monitoring, once they present more sensibility than other phosphors, like LiF:Mg. Theirs mainly disadvantage is a strong energetic dependence response, which must be corrected for theirs application in the field, where photon ...

2006-07-01

156

Predictive model of electron-beam-induced flashblindness. Final report, November 1983-October 1984  

Energy Technology Data Exchange (ETDEWEB)

The spectral characteristics of the Cherenkov radiation have been evaluated and converted to equivalent retinal irradiance from external sources. On the basis of the conversion, electron fluxes have been estimated for 2-sec recovery times from flashblindness. The electrons are assumed to have energies greater than 6 MeV and to be delivered in one or more bursts of 1 microsecond each over 1 sec. It is important to note that very little data exists on recovery times as short as 2 sec for either photopic and scotopic conditions. This situation is a direct result of the lack of definition of the critical tasks and their sensitivity to an interruption of background adaptation. The Cherenkov radiation produced within the eye by relativistic electrons can be compared to light from external sources by the relationships: 1 rad approx. = 4.6 scotopic td-sec and 1 rad approx. = 0.55 photopic td sec. Based on these conversion factors, the following estimates can be derived by ...

1985-03-01

157

In vitro H2AX phosphorylation and micronuclei induction in human fibroblasts across the Bragg curve of a 577MeV/nucleon Fe incident beam  

Energy Technology Data Exchange (ETDEWEB)

The space environment consists of a varying field of radiation particles including high-energy ions, with spacecraft shielding material providing the only major protection to astronauts from harmful exposure. Unlike low-linear energy transfer (LET) {gamma} or X-rays, the presence of shielding does not always reduce the radiation risks for energetic charged particle exposure, since the dose delivered by the charged particle increases sharply as the particle approaches the end of its range, a position known as the Bragg peak. The Bragg curve does not necessarily represent the biological damage along the particle traversal, and the 'biological Bragg curve' is dependent on the energy and the type of the primary particle, and may vary for different biological endpoints. Here we used a unique irradiation geometry to measure the biological response across the Bragg curve in human fibroblasts exposed to ...

2006-10-15

162

Automatic system for measuring dose-area product (DAP) in ROI fluoroscopy  

Energy Technology Data Exchange (ETDEWEB)

A computerized system for monitoring dose-area product (DAP) has been developed for region of interest (ROI) fluoroscopy in which patient exposure is reduced using an x-ray attenuating filter with an aperture. The system includes an IBM compatible computer which is connected through an IEEE-488 interface to an electrometer which measures the charge from a DAP ionization chamber. A digital input/output board connects the computer to the filter placement device to determine whether the filter is in or out of the beam, and to the x-ray generator to determine when the exposure is due to spot filming. The computer logs the DAP from conventional fluoroscopy, ROI fluoroscopy and spot filming separately, applying the appropriate calibration factor for each. Measured DAPs, fluoroscopic DAP rates and exposure times are displayed in real-time. The system has been installed in a GI fluoroscopic room so that the ...

1997-04-01

163

The X-ray Ordinance  

International Nuclear Information System (INIS)

The sections and provisions of the X-ray Ordinance of January 8, 1987 are discussed which are of relevance to dental radiology. (DG).

164

DoseWatchers - A computer based X ray dose monitoring project in paediatric radiology  

International Nuclear Information System (INIS)

Full text: Introduction. Children, especially premature infants and neonates, are at a much higher risk to obtain an X ray induced disturbance of life - particularly cancer. On the one hand this is due to their longer life expectancy and on the other hand it is due to their higher cell proliferation rate. The paediatric radiology unit of the Inselspital Bern recently installed some of the most advanced X ray equipment nowadays available. It is based on the two latest digital technologies: double read computed radiography (CR) and direct digital radiography (DR). Only the implementation of these digital radiography systems permits the digital acquisition and additionally the analysis of acquired data. The systematic analysis of large amounts of biometric data and exposition data is the basis for further dose reduction and a systematic quality control (QC). Patients are increasingly ...

2006-11-13

165

Gene rearrangement and radiation carcinogenesis  

International Nuclear Information System (INIS)

The development of leukemia and thyroid cancer is characterized by activation of the abl oncogene and ret oncogene, respectively. In order to clarify the relationship between these gene aberrations and radiation, the pro-myelogenous leukemia-derived cell line HL60 and the thyroid cancer-derived cell line 8505C, were irradiated in vitro with 100Gy of X-rays. RNA was then extracted from 10"8 cells of the respective cell lines and examined by the reverse transcription PCR method for rearrangements of abl and ret genes. Five kinds of positive bands were observed in the HL-60 cells irradiated with 100Gy of X-ray. Similarly, six positive bands were also observed in the 8505C cells irradiated with 100Gy. In vitro X-irradiation activation of oncogenes found in radiation induced cancers imply that gene rearrangement by X-rays is involved in the ...

1993-11-01

166

Preparation of AgCl Nanoparticles@Ancient Textile with Antibacterial Activity under Ultrasound Irradiation  

British Library Electronic Table of Contents (United Kingdom)

The growth of silver chloride nanoparticles on ancient textile was achieved by sequential dipping steps in alternating bath of potassium chloride and silver nitrate under ultrasound irradiation. The effect of ultrasound irradiation and sequential dipping steps in growth of the AgCl nanoparticles has been studied. These systems depicted a decrease in the particles size accompanying a decrease in the sequential dipping steps. The samples were characterized with powder X-ray diffraction (XRD) and scanning electron microscopy. XRD analyses indicated that the prepared AgCl nanoparticles on fiber were crystalline. The textile samples containing AgCl nanoparticles were tested for their antibacterial efficacy against Escherichia coli and were found to possess significant antibacterial activity.

2011-01-01

167

Effect of minor alloying elements and their segregation on void suppression in modified 316 stainless steel  

International Nuclear Information System (INIS)

The effects of modification with Ti and Nb, heat treatment and solute segregation on void suppression in 316 stainless steel were studied using HVEM in the temperature range of 623-873 K after solution treatment at 1323-1473 K. Post-irradiation compositional analysis was performed by an energy dispersive X-ray analyzer. In Ti-modified stainless steel, void swelling peaks appeared at 723 K and 823 K. On the other hand, when the stainless steels modified by both Ti and Nb were irradiated, the void swelling was effectively suppressed, particularly the growth rate of a void was remarkedly retarded. This void suppression effect was easily recognized with increasing Nb concentration. Compositions such as Mo, Cr, Ti and Ni changed during irradiation and Ni, Si and Ti enriched around voids, whereas Cr and Mo depleted. (orig.).

1983-09-01

168

Comparative evolution of various CCD image sensors hardening techniques with ionizing radiation  

International Nuclear Information System (INIS)

This paper reviews various techniques to harden Charged Coupled Device (CCD) sensors and the results after irradiation of three Thomson n buried channel CCDs having a different degree of hardening. It describes the major irradiation effects on CCD performances and it makes a comparison of the results between the different hardening levels. It shows good results on dark voltage after ionizing radiation for TH 7863M device hardened both by design and by operating conditions (MPP mode) with respect to the standard device TH 7863A. The irradiations were performed with "6"0Co or X-ray (10 keV) sources on devices in operating mode. (author). 3 refs., 8 figs.

169

Irradiation hardening of reduced activation martensitic steels  

International Nuclear Information System (INIS)

Irradiation response on the tensile properties of 9Cr-2W steels has been investigated following FFTF/MOTA irradiations at temperatures between 646 and 873 K up to doses between 10 and 59 dpa. The largest irradiation hardening accompanied by the largest decrease in the elongation is observed for the specimens irradiated at 646 K at doses between 10 and 15 dpa. The irradiation hardening appears to saturate at a dose of around 10 dpa at the irradiation temperature. No hardening but softening was observed in the specimens irradiated at above 703 K to doses of 40 and 59 dpa. Microstructural observation by transmission electron microscope (TEM) revealed that the dislocation loops with the a left angle 100 right angle type Burgers vector and small precipitates which ...

170

Body dose conversion factors for computerized tomography  

International Nuclear Information System (INIS)

While there have been many experimental and calculational investigations on absorbed dose distribution in the patient resulting from conventional X-ray procedures, such data for computerized tomography (CT) are still sparse. As this diagnostic procedure has shown a rapid increase in application during recent years, we have determined absorbed dose to body organs in a human phantom resulting from CT examinations. The exposure model consists of the heterogeneous MIRD-5 phantom and a suitable Monte-Carlo method to calculate absorbed dose to organs of interest. The exposure conditions are specified according to the exposure specifications of a CT-scanner currently in use. The calculations cover the range of body tissues of interest in terms of organ absorbed doses as well as a risk weighted absorbed dose. A detailed example showing the calculation of red bone marrow ...

1980-10-31

172

Experimental and clinical studies on the usefulness and assessment of the angiographic images processed by a digital radiography system (FCR: Fuji Computed Tomography)  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film arteriogram even with a ...

1989-06-01

173

Experimental and clinical studies on the usefulness and assessment of the angiographic images processed by a digital radiography system (FCR: Fuji Computed Tomography)  

International Nuclear Information System (INIS)

The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film arteriogram even with a ...

1989-01-01

174

Analyses of superficial and depth doses in intraoral radiology  

Energy Technology Data Exchange (ETDEWEB)

In this work dosimetric analysis using thermoluminescence technique to study the beams characteristics of x-rays employed in dental radiology has been carried out. The obtained results with CaSO{sub 4}:Dy thermoluminescent dosimeters (TLD) were compared to the doses obtained with parallel-plates ionization chamber. Dosimetric evaluations were also done using radiographic films of large dimensions. The x-rays equipments analyzed were installed in the radiological services of Odontology Department of Sergipe Federal University (U.F.S.). Depending on the anatomical region to be examined the proper exposure time was select, for a fix voltage of 70 kV. The results with TLD and ionization chamber have been determined to female and male individuals. The intraoral regions analysed were the peri apical of the incisors, molar and pre-molar teeth and the occlusive region. These regions were simulated using acrylic plates absorbers ...

2006-07-01

175

Induction of sterility in adults of Earias vittella Fabricius through late pupal irradiation  

International Nuclear Information System (INIS)

Studies on pupal irradiation of Earias vittella Fabricius, were undertaken to determine the optimum dose for sterile and competitive adults. Late pupae were irradiated with gamma radiation doses ranging from 150 to 300 Gy. Emerging adults were normal and without malformation. When males that emerged from irradiated pupae were crossed with normal female, fecundity as well as longevity was comparable to control, but there was drastic reduction in percent egg hatch in all the treatments. However, when females emerging from irradiated pupae were crossed with normal male, there was reduction in the fecundity as well as fertility and this effect was dose dependent. (author).

176

Analysis of o-tyrosine as a method for the identification of irradiated chicken and the comparison with other methods (analysis of volatiles and ESR-spectroscopy)  

Energy Technology Data Exchange (ETDEWEB)

With the mentioned method to analyse O-tyrosine with HPLC/fluorescence-detection, the irradiation of chicken meat can be determined in a simple and fast way. The formation of o-tyrosine is proportional to the applied dose but because it is also depending on the applied dose rate and the temperature during the irradiation, it is not possible to control the irradiation dose. Since unirradiated chicken can contain little amounts of o-tyrosine and to confirm some results, a second method is needed. Together with one of the other mentioned methods (analysis of the volatiles or esr-spectroscopy) it is possible to recognize irradiated chicken with a high security. (author).

1990-01-01

177

Reports of the second All-Union conference on the chemistry of transplutonium elements (Dmitrovgrad, June 21-23, 1963)  

Energy Technology Data Exchange (ETDEWEB)

The nine papers presented at this conference cover the following topics: the systematization, condensed description, and prediction of sets of anion exchange extraction constants on the basis of their statistical computer treatment; characteristics and uses of solid extractants containing D2EHPA and TBP for separating the transplutonium elements; enrichment of americium 242m and americium 242 by the Szilard-Chalmers method; an x-ray diffraction pattern analysis for transplutonium compounds; the radiation chemistry of americium; and the effects of alpha irradiation on the behavior of americium in perchlorate solutions.

1987-05-01

178

Interpretation of EXAFS data from laser shock compressed plasmas  

Energy Technology Data Exchange (ETDEWEB)

Measurements on laser shock compressed aluminium using the EXAFS (Extended X-ray Absorption Fine Structure) technique on the Al K-edge are described. Two methods of analysis of this data were used for the determination of density: the standard EXAFS technique using Fourier transforms and curve fitting, and a method based on a bandstructure calculation of the absorption spectra as a function of compression. These two techniques give results which are in fairly good agreement with each other and also with a hydrodynamic simulation of the experiment. The ion correlation parameter is estimated and shows that two-sided laser irradiation of aluminium foils produces a dense plasma which is strongly coupled. (author).

1989-01-01

179

Experimental research on X-ray spectrum emitted from hot laser-produced aluminium plasma  

International Nuclear Information System (INIS)

The hot uniform aluminium plasma was produced by irradiating thin aluminium dotted foil smoothly with the 9th 0.53 ?m laser on Shenguang II laser facility. The emitted spectrum was measured from the front and tangential direction of the target with two crystal spectrometers, and the quantitative spectrum from the front of the target was obtained. The state of laser- produced plasma was simulated with the radiation hydrodynamics code MULTI-1D, and the emitted spectrum was calculated with the spectrum code of Collision-Radiation model under the simulated plasma state. The experimental spectrum accords with the simulated one. (authors)

2007-12-01

180

CMOS/SOI hardening at 100 MRAD (SiO_2)  

International Nuclear Information System (INIS)

Hardened CMOS/SOI 29101 microprocessor, elementary cells and transistor shave been irradiated at levels between 10 Mrad(SiO_2) and 1 Grad(SiO_2) ("6"0Co and 10 keV x-rays). SIMOX buried oxide behavior in the range of 100 Mrad(SiO_2) and a channel-stopped MOS/SOI structure avoiding lateral leakage current are presented. These two items indicate the feasibility of a CMOS/SOI technology operating in the hundred Mrad(SiO_2) range.

1990-07-16

181

Occurrence of mutations in the epidermal growth factor receptor gene in X-ray-induced rat lung tumors  

International Nuclear Information System (INIS)

Epidermal growth factor receptor (EGFR) gene alterations have been found in human lung cancers. However, there is no information on the factors inducing EGFR mutations. In rodents, K-ras mutations are frequently found in many lung carcinogenesis models, but hitherto, Egfr mutations have not been reported. Their presence was therefore investigated in representative lung carcinogenesis models with 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), N-nitrosobis(2-hydroxypropyl)amine (BHP), 2-amino-3,8-dimethylimidazo[4,5-f]quinoxaline (MelQx) and ethyl carbamate (urethane), as well as X-ray irradiation. With the chemical carcinogenesis models, no mutations were detected in Egfr, which is in clear contrast to the high rates observed in either codon 12 or 61 of K-ras (21/23 of the lung tumors induced with NNK, 4/5 with MelQx, 1/4 with urethane and 7/18 with BHP). However, in the X-ray-induced lung tumors, Egfr mutations with ...

2008-02-01

182

The determination of optical conditions of Fuji computed radiography (FCR) in pelvimetry and the reduction of radiation dose to mother and fetus  

Energy Technology Data Exchange (ETDEWEB)

The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).

1991-05-01

183

The determination of optical conditions of Fuji computed radiography (FCR) in pelvimetry and the reduction of radiation dose to mother and fetus  

International Nuclear Information System (INIS)

The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).

1991-01-01

184

Radiation hazard control report  

Energy Technology Data Exchange (ETDEWEB)

The radiation control carried out in Atomic Energy Research Institute, Kinki University, for the reactor installation and the tracer/accelerator facilities from April, 1981, to March, 1982, is described. The reactor was operated for total 1057.1 hours at the maximum heat output of 1 W. The persons subject to radiation protection as of April, 1981, were 126 persons in all, including 23 in radiation work and 11 in X-ray work, etc. The contents of this report are as follows: personnel monitoring (health examination, the control of individual exposure dose); laboratory monitoring (the measurement of area dose rate, radioactive concentration in air and water, and surface contamination density); field monitoring (environmental ..gamma..-ray dose rate, radioactive concentration in environmental samples); the use of unsealed radioisotopes, etc.

1982-12-01

185

Normalized noise power spectrum of full field digital mammography detector system  

International Nuclear Information System (INIS)

Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)

186

Normalized Noise Power Spectrum of Full Field Digital Mammography System  

International Nuclear Information System (INIS)

A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.

2010-01-05

187

An integrating dosimeter for pulsed radiation  

Science.gov (United States)

A Pulsed Radiation Dosimetry System designed to measure radiation produced by particle accelerators is described. The problems associated with total-dose measurement of irregular shaped pulses of ionizing radiation have been simplified. The system responds to extremely narrow pulses of charged particles or X-rays using a pin diode as the detector. Direct readout of dose in rads (Si) is displayed on a 3-1/2 digit digital panel meter. The system will operate in either the multiple-pulse or single-pulse mode. The multiple-pulse mode would be useful in monitoring or tuning a linear accelerator. In the single-pulse mode the system will automatically display total dose of a transient event in real time and hold that measurement indefinitely or until the next measurement is made. The system features an automatic reset in either mode.

1983-12-01

188

Performance testing of selected types of electronic personal dosimeters used in Sudan  

International Nuclear Information System (INIS)

Measurements were carried out for calibration and performance testing of a set of 10 electronic personal dosimeters (EPDs) at the Secondary Standard Dosimetry Laboratory of Sudan. Calibrations were carried out at three X-ray beam qualities described in ISO standard 4037 in addition to 137Cs and 60Co gamma ray beams. The experimental was performed with EPDs mounted on ICRU Slab phantom. X-ray and ?-ray beams were characterized in terms of air kerma free-in-air which were converted to the known delivered personal dose equivalent, Hp(10) using appropriate the air kerma to personal dose equivalent conversion coefficients. Dosimeters tested showed excellent energy and angular response and relative error of indication within the recommended limit for photon energies from 65 keV to 1.25 MeV. The study showed encouraging results for using electronic dosimeters in personal dosimetry.

2010-12-01

189

Treatment of uteral cancer by the brake irradiation (25 MeV)  

International Nuclear Information System (INIS)

The method of treatment of uteral cancer by the brake irradiation of 25 MeV betatrone using original devices which promote forming therapeutic figured bunches is presented. The binding of the protective blocks with a special adjusting frame within the aperture of the diaphragm provided for low relative entering dose which is the advantage of high energy irradiation bunch. The use of the forming devices makes it possible to practice individual treatment and decrease the levels of irradiation doses for intact organs and tissues.

190

Structural changes in amorphous Pd_8_0Si_2_0 and Pd_7_7_._5 Cu_6 Si_1_6_._5 alloys caused by neutron irradiation  

International Nuclear Information System (INIS)

The present work is to study effects of neutron irradiation on the structure of amorphous Pb_8_0 Si_2_0 and Pd_7_7_._5 Cu_6 Si_1_6_._5 alloys by using X-ray diffraction techniques. differential scanning calorimertry (DSC) and internal friction measurements. The irradiation will produce obvious changes in the pair correlation function g(r) and radial distribution function RDF (r). The increase of crystallization temperature (Tx) and enthalpy of two specimens were found by DSC measurements after irradiation. The results of internal friction measurement show that the internal friction of the irradiated Pd_8_0Si_2_0 alloy is higher than that of the unirradiated in the temperature range of Tirradiation are discussed in terms of the concepts of density fluctuation defects (p) and shear stress fluctuation defects ...

191

Phase imaging using laser-produced X-ray sources  

International Nuclear Information System (INIS)

A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. The authors established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging

2000-08-01

192

Photoluminescence Decay of Irradiated Herbs  

Energy Technology Data Exchange (ETDEWEB)

Thermoluminescence of inorganic dust extract from herbs and spices has been demonstrated to be a useful method to discriminate irradiated food products as well as to estimate the total dose exposure. The time evolution of infrared stimulated luminescence has been systematically investigated in potassium feldspar and albite minerals subjected to different doses of gamma irradiation (ranging from 0 to 8 kGy). Experimental results reveal a 300-600 nm signal which is greatly intensified for irradiated samples, following the same irradiation dose dependence observed in thermoluminescence. The luminescence intensity disappears after few seconds of illumination, following a time evolution which is proportional to (1 + Bt){sup -P}. The influence of both B and P factors upon the irradiation dose has been ...

1999-07-01

193

Photoluminescence Decay of Irradiated Herbs  

International Nuclear Information System (INIS)

Thermoluminescence of inorganic dust extract from herbs and spices has been demonstrated to be a useful method to discriminate irradiated food products as well as to estimate the total dose exposure. The time evolution of infrared stimulated luminescence has been systematically investigated in potassium feldspar and albite minerals subjected to different doses of gamma irradiation (ranging from 0 to 8 kGy). Experimental results reveal a 300-600 nm signal which is greatly intensified for irradiated samples, following the same irradiation dose dependence observed in thermoluminescence. The luminescence intensity disappears after few seconds of illumination, following a time evolution which is proportional to (1 + Bt)"-"P. The influence of both B and P factors upon the irradiation dose has been ...

1998-07-05

194

Radiation induced micrencephaly in guinea pigs  

International Nuclear Information System (INIS)

A brain weight deficit of about 70 mg was induced at doses of approximately 75-mGy and a deficit of 60 mg was induced at 100 mGy. This confirms the effects projected and observed by Wanner and Edwards. Although the data do not demonstrate a clear dose-response relationship between the 75-mGy and 100-mGy groups, the data are statistically consistent with a dose-response effect because of the overlapping confidence intervals. The lack of a statistically significant observation is most likely related to the small difference in doses and the limited numbers of animals examined. There are several factors that can influence the brain weight of guinea pig pups, such as caging and housing conditions, the sex of the animal, and litter size. These should be taken into account for accurate analysis. Dam weight did not appear to have a significant effect. The confirmation of a micrencephalic effect induced ...

2006-04-20

195

Evaluation of the increase of superficial dose due to thermoplastic immobilizing in radiotherapy; Avaliacao dos efeitos de superficializacao de dose por imobilizadores termoplasticos em radioterapia  

Energy Technology Data Exchange (ETDEWEB)

Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin dose ...

2010-07-01

196

Characterization of arsenic dose loss at the Si/SiO{sub 2} interface  

Energy Technology Data Exchange (ETDEWEB)

Careful sample preparation and secondary ion mass spectroscopy have been used to characterize arsenic dose loss to the silicon-oxide interface. Using high resolution x-ray photoelectron spectroscopy for microprofiling, we have directly observed the pileup of arsenic at the silicon dioxide-silicon interface. At least half of the pileup is shown to be on the silicon side of the interface in the first monolayer of silicon. Monolayer chemical oxidation and etching are successfully used to profile this pileup in silicon. This pileup contains most of the arsenic dose loss that occurs during transient enhanced diffusion. This result is crucial to correctly model the dose loss and provides physical justification for using a trap/detrap model at the interface, which is necessary to account for the fact that the arsenic surface concentration remains constant during an anneal and the fact that the ...

2000-03-01

197

Characterization of arsenic dose loss at the Si/SiO_2 interface  

International Nuclear Information System (INIS)

Careful sample preparation and secondary ion mass spectroscopy have been used to characterize arsenic dose loss to the silicon-oxide interface. Using high resolution x-ray photoelectron spectroscopy for microprofiling, we have directly observed the pileup of arsenic at the silicon dioxide-silicon interface. At least half of the pileup is shown to be on the silicon side of the interface in the first monolayer of silicon. Monolayer chemical oxidation and etching are successfully used to profile this pileup in silicon. This pileup contains most of the arsenic dose loss that occurs during transient enhanced diffusion. This result is crucial to correctly model the dose loss and provides physical justification for using a trap/detrap model at the interface, which is necessary to account for the fact that the arsenic surface concentration remains constant during an anneal and the fact that the ...

2000-03-01

198

Portal localization images using computed radiography for high-energy electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy electron beam therapy. (author)

2002-09-01

199

X-ray magnetic circular dichroism measurements using an X-ray phase retarder on the BM25 A-SpLine beamline at the ESRF  

UK PubMed Central (United Kingdom)

Circularly polarized X-rays produced by a diamond X-ray phase retarder of thickness 0.5 mm in the Laue transmission configuration have been used for recording X-ray magnetic circular dichroism...Full Text Available

2010-05-01

200

Mammary carcinogenesis in the rat after low-dose irradiation  

International Nuclear Information System (INIS)

Carcinogenesis is now generally recognized to be an important detrimental effect in man after low dose irradiation. The carcinogenic action of ionizing radiation is clearly demonstrated after exposure to relatively high doses (in excess of 0.5 Gy) but for lower dose levels reliable direct observations are not available. With the introduction of special protocols for the performance of large scale screening programs by mammography the average absorbed dose in glandular tissue in the average breast can be restricted to a value of 3 mGy per mammogram. The risk for tumor induction after exposure to these low doses can never be established from human epidemiology. In order to investigate the risk of repeated exposure to small dose of ionizing radiation the induction of mammary tumors has been investigated in rats of the WAG/Rij strain after ...

1992-07-12

201

Radiation, adriamycin, and skin reactions: effects of radiation and drug fractionation, hyperthermia, and tetracycline. [X rays  

Energy Technology Data Exchange (ETDEWEB)

The effect of adriamycin in combination with radiation on the skin reactions of mouse feet has been examined under a variety of experimental conditions including: (a) hyperthermic treatment of the foot immediately following adriamycin administration, with the former given either just before or just after x irradiation, and (b) fractionated treatments of drug and radiation in a variety of sequences over an 18-day period. In the case of the most severe hyperthermic treatment, no increased radiation reactions were observed in the presence of adriamycin. However, in the case of the less severe hyperthermic treatment a small but significant increase in skin reactions was observed. In the study of fractionated drug and radiation treatments, an enhancement of reaction in those animals receiving combined modality treatment over those receiving radiation alone was seen in those groups where the initiation of drug treatment succeeded the initiation of radiation treatment by ...

1981-06-01

202

Photocatalytic self-cleaning properties of cellulosic fibers modified by nano-sized zinc oxide  

International Nuclear Information System (INIS)

Nano-sized zinc oxide was synthesized and deposited onto cellulosic fibers using the sol-gel process at ambient temperature. The prepared materials were characterized using several techniques including scanning electron microscopy, transmission electron microscopy, diffuse reflectance spectroscopy, X-ray diffraction and thermogravimetric analysis. X-ray diffraction studies of the ZnO-coated fiber indicate formation of the hexagonal crystal phase which was satisfactory crystallized on the fiber surface. The electron micrographs show formation of zinc oxide nanoparticles within 10-15 nm in size which have been homogeneously dispersed on the fiber surface. The prepared materials show significant photocatalytic self-cleaning activity, which was monitored by diffuse reflectance spectroscopy. The photoactivity was studied upon measuring the photodegradation of methylene blue and eosin yellowish under UV-Vis irradiation. The ...

2011-03-31

203

Beam Test of a Prototype Detector Array for the PoGO Astronomical Hard X-Ray/Soft Gamma-Ray Polarimeter  

CERN Document Server

Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \\pm 0.01$. This was successfully reproduced at the 10% level by the computer simulation package Geant4 after modifications to its implementation of ...

2005-01-01

204

Coloring of cultured pearls by gamma-rays irradiation  

International Nuclear Information System (INIS)

Changing cream pearls into bluish-grey by #gamma# ray irradiation is a technique in coloring of pearls. Irradiated pearls are similar in color to cultured blue pearls. The pearl layers hardly change their color but the nuclei change into dark brown by irradiation. Visible light (500 - 700 nm) penetrating the pearl layer is absorbed by dark brown nucleus. The intensity of reflecting light between 400 and 500 nm at pearl surface, therefore, becomes stronger than that between 500 and 700 nm; therefore color of irradiated pearls look bluish-grey. The density of bluish-grey color increases with increasing absorbed doses, but their luster at surface diminishes owing to the deterioration of the pearl layer by prolonged irradiation; high doses irradiation should be avoided. Irradiated pearls show no ...

205

Dosimetry measurements of x-ray and neutron radiation levels near the shuttle and end beam dump at the advanced test accelerator: Beam Research Program  

International Nuclear Information System (INIS)

Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that may be used for diagnostics. To provide ...

206

Somatic and genetic radiation exposure of the patient in digital subtraction angiography (DSA)  

International Nuclear Information System (INIS)

The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation doses absorbed within the critical organs - red bone marrow, lung, thyroid gland and female breast - and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. projection, the use of an abdominal compression device and careful caudal shielding of the field are ...

1986-01-01

207

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial pilot studies with ...

2008-06-01

208

Procedure for radiation dose control in irradiated tissues during electron-beam therapy  

International Nuclear Information System (INIS)

The invention refers a procedure of radiation dose control in irradiated tissues during electron-beam therapy. It aims at meeting the planned radiation dose for diseased tissues and taking care of the healthy ones. Therefore, the dose distribution required is determined before irradiation in consideration of such factors as energy-dependence of detector sensitivity, self-absorption within the tissue, and relative biological effectiveness. Furthermore, the expected intensity distribution of secondary quantum radiation excited in the irradiated tissue is calculated. A radiation detector for local resolution is used for registration. During irradiation the calculated intensity distribution is compared with the measured one. The invention is applicable in radiation therapy with monoenergetic electron beams.

1984-11-08

209

Evaluation of the increase of superficial dose due to thermoplastic immobilizing in radiotherapy  

International Nuclear Information System (INIS)

Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin dose ...

2010-08-18

210

A water calorimeter for high energy x-rays and electrons  

CERN Document Server

The current primary standards at NPL for the measurement of absorbed dose to water in high energy photon and electron beams are graphite calorimeters. However, the quantity of interest in radiation dosimetry is absorbed dose to water. Therefore, a new absorbed dose to water standard based on water calorimetry has been developed for use in high energy photon and electron beams. The calorimeter operates at 4 deg C, with temperature control being provided by liquid cooling. The sealed glass inner vessel of the calorimeter was designed to minimise the effect of non-water materials on the measurement of absorbed dose. The temperature sensing thermistor probes were designed and constructed so that glass is the only material in contact with high purity water inside the vessel. Initial measurements of absorbed dose to water made in 6, 10, and 19 MV photons, and 16 MeV electrons agreed, ...

2000-01-01

211

X-ray stars in globular clusters  

Science.gov (United States)

The properties and kinetics of x-ray stars in globular clusters are described. Locations, configurations, star evolution, massive close binary systems, various mechanisms, and the x-ray burster properties are included. (JFP)

1977-10-01

212

Position-sensitive proportional counter for space-based X-ray imaging studies  

International Nuclear Information System (INIS)

ASTROSAT, India's first dedicated astronomy satellite is slated for launch in 2007. The primary science objective of ASTROSAT is to explore the Universe using broad-band instruments covering optical, UV, soft X-ray and hard X-ray studies

2005-03-01

213

Beam-induced damage on diffractive hard X-ray optics  

UK PubMed Central (United Kingdom)

The issue of beam-induced damage on diffractive hard X-ray optics is addressed. For this purpose a systematic study on the radiation damage induced by a high-power X-ray beam is carried out in both...Full Text Available

2010-11-01

214

The characterization of electron beam and its importance  

International Nuclear Information System (INIS)

The necessity of the electron beam machine characterization via dose measurement is discussed. It includes a measurement of comprehensive dose distribution (at known X and Z axis) for verification of the machine performance. The acquired data were then used to develop the irradiation parameters such as energy, current, distance, conveyor speed, exposure rate and depth inside product to be irradiated. These parameters will be used as a guide for the routine irradiations. (Author)

2003-07-22

215

Decree of the Ministry of Health about conditions of irradiation of food, permissible additional substances or other food components, which can be subjected to ionizing radiation action, their specification, maximum irradiation doses as well as about requirements for marking and introducing into turnover  

International Nuclear Information System (INIS)

The decree refers to conditions of irradiation of food and its components for radappertization and radurization using gamma radiation from cobalt 60 or cesium 137, X radiation or electron beam up to maximum total medium absorbed dose 10 kGy.

2003-03-04

216

The dependence of radiation hardening and embrittlement on irradiation temperature  

International Nuclear Information System (INIS)

Assessments of the hardening and embrittlement of pressure vessel steels and welds as a function of neutron dose use trend curves derived from surveillance programs and accelerated irradiation data. A temperature dependent factor is incorporated for assessing vessel locations operating at different temperatures. As hardening and embrittlement arise from the sum of matrix damage and copper impurity precipitation, the influence of irradiation temperature on each process needs to be established. For irradiations performed below #approx# 300 C recent data shows that the dose-dependent growth of copper precipitates ceases at a mean diameter of about 2 nm that also corresponds to peak hardening and embrittlement by copper. For doses beyond this peak copper dose the property-dependence on irradiation temperature can be ...

1994-06-20

217

Photoacoustic response to X-ray absorption in copper and brass  

Energy Technology Data Exchange (ETDEWEB)

The X-ray photoacoustic spectra of copper and brass (64.7 wt.% Cu and 35.3 wt.% Zn) have been measured at XANES (X-ray absorption near-edge structure) regions using synchrotron radiation. These spectra were compared with optical density of X-ray spectra. It is shown that the information derived from XANES is also included in the X-ray photoacoustic spectrum which reflects the heat production processes in copper and brass. However, the results showed that the increases and changes of the photoacoustic signal were different from those of the X-ray absorption coefficient at XANES regions. (author).

1990-09-01

218

Generation of microwaves and hard X-rays in a flash X-ray tube  

Energy Technology Data Exchange (ETDEWEB)

High interelectrode voltage peaks have been observed simultaneously with the emission of hard X-ray bursts from a flash X-ray tube. The magnitude of the voltage peaks may exceed twice the initial charging voltage. It has also been observed that the discharge emits bursts of X-and P-band microwaves radiation which are coincident with the emission of the hard X-ray bursts. The results indicate that the microwaves and X-rays have a common origin in discharge plasma movements and an acceleration model for electrons in the plasma is presented as one possible explanation of the observed phenomena.

1982-01-01

219

Neutron irradiation of superconducting compounds  

International Nuclear Information System (INIS)

The effects of neutron irradiation on the superconducting and normal state properties of alloys and compounds are presented. Particular emphasis is placed on the A-15 compounds where the effects of neutron irradiation on Tsub(c), Hsub(c_2), long range order parameter and lattice parameter are described. Large depressions (up to 80%) in Tsub(c) are observed for all the A-15 compounds studied with the exception of Mo_3Os where much smaller decreases in Tsub(c) are seen. Along with the decrease in Tsub(c) and increase in lattice parameter, the degree of long range order, as measured by X-ray and neutron diffraction, decreases. Also presented are the results of isothermal and isochronal anneals up to 900"0C. The unirradiated value of Tsub(c) can be restored by annealing, and for those systems where measurements have been made, recovery of the lattice parameter and order parameter also takes place. The effects observed in ...

220

x - NASA Technical Reports Server  

Science.gov (United States)

Mar 1, 2011 ... Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation ...

222

NASA Technical Reports Server - Radionuclide X-ray fluorescence ...  

Science.gov (United States)

Aug 1, 1972 ... The principles of radionuclide excitation of X-ray fluorescence radiation and its application in analytic chemistry are discussed.

223

A comparison of the X-ray properties of X Per and gamma Cas  

Energy Technology Data Exchange (ETDEWEB)

The X-ray properties of the main sequence Be stars conclude that they are a widely separated binary system containing an accreting neutron star.

1982-04-01

224

Depth-profiling of vertical sidewall nanolayers on structured wafers by grazing incidence X-ray flourescence  

Energy Technology Data Exchange (ETDEWEB)

The Physikalisch-Technische Bundesanstalt (PTB), Germany's national metrology institute, developed an alignment strategy to specify elemental depth profiling in vertical sidewall layers on structured wafers. For this purpose, PTB's irradiation chamber for 200 mm and 300 mm silicon wafers was used to combine total-reflection X-ray fluorescence (TXRF) and grazing incidence XRF (GIXRF) techniques by employing monochromatized undulator radiation of the BESSY II electron storage ring. 3-D test structures were fabricated to develop an optimal alignment strategy allowing for depth profiling in such nanolayers. The test structures consisted of silicon bars with widths/spacings either in the {mu}m or in the nm range. In order to be able to differentiate the sidewalls more easily from the remainder of the structures, they were provided with an additional silicon nitride layer. Four structure types of different bar width and density ...

2008-12-15

225

Depth-profiling of vertical sidewall nanolayers on structured wafers by grazing incidence X-ray flourescence  

International Nuclear Information System (INIS)

The Physikalisch-Technische Bundesanstalt (PTB), Germany's national metrology institute, developed an alignment strategy to specify elemental depth profiling in vertical sidewall layers on structured wafers. For this purpose, PTB's irradiation chamber for 200 mm and 300 mm silicon wafers was used to combine total-reflection X-ray fluorescence (TXRF) and grazing incidence XRF (GIXRF) techniques by employing monochromatized undulator radiation of the BESSY II electron storage ring. 3-D test structures were fabricated to develop an optimal alignment strategy allowing for depth profiling in such nanolayers. The test structures consisted of silicon bars with widths/spacings either in the ?m or in the nm range. In order to be able to differentiate the sidewalls more easily from the remainder of the structures, they were provided with an additional silicon nitride layer. Four structure types of different bar width and density parameters on two 200 mm ...

2008-12-01

226

Metrological applications of X-ray waveguide thin film structures in X-ray reflectometry and diffraction  

International Nuclear Information System (INIS)

The effect of resonance, observed in X-ray waveguide layered structures in a characteristic way influences the scattering properties of the films. It is well known that the resonant region in the reflectivity shows a series of minima, usually very deep and extremely narrow. The positions and depths of the minima depend only on X-ray waveguide and quasi X-ray waveguide film structural properties, on the X-ray wavelength and on the incident beam divergence. In the present work we propose and discuss the application of the X-ray waveguide and quasi X-ray waveguide film structures as a tools to experimental evaluation of some quantities related to X-ray reflectometric and diffractometric measurements, like the beam divergence, wavelength, or angular distance. Examples of application of X-ray waveguide as an excellent tool ...

2001-09-23

227

Punica granatum peel extract protects against ionizing radiation-induced enteritis and leukocyte apoptosis in rats  

International Nuclear Information System (INIS)

Radiation-induced enteritis is a well-recognized sequel of therapeutic irradiation. Therefore we examined the radioprotective properties of Punica granatum peel extract (PPE) on the oxidative damage in the ileum. Rats were exposed to a single whole-body X-ray irradiation of 800 cGy. Irradiated rats were pretreated orally with saline or PPE (50 mg/kg/day) for 10 days before irradiation and the following 10 days, while control rats received saline or PPE but no irradiation. Then plasma and ileum samples were obtained. Irradiation caused a decrease in glutathione and total antioxidant capacity, which was accompanied by increases in malondialdehyde levels, myeloperoxidase activity, collagen content of the tissue with a concomitant increase 8-hydroxy-2'-deoxyguanosine (an index of oxidative DNA damage). Similarly, pro-inflammatory cytokines ...

2009-07-01

228

Fluence- and exposure-to-dose conversion for human whole-body gamma irradiation  

International Nuclear Information System (INIS)

... kev range 10-100 kev range 100-1000 man mev range 01-10 personnel

1978-01-01

230

ESR dosimetry of irradiated chicken legs and chicken eggs  

Energy Technology Data Exchange (ETDEWEB)

Ionising radiation induces stable free radicals in chicken bones and in the shell of chicken eggs which can be detected, by the electrons spin resonance (ESR) technique, well beyond the shelf-life of the food and can be used for dosimetry. The method usually adopted to evaluate ``a posteriori`` the dose given during the ionising radiation treatment of food, is the dose additive method. To assess the dose, the ESR signal amplitude of the irradiated food (bone or egg shell in the present case) is measured and then the dose-effect relationship is obtained by re-irradiating the sample with some additive doses (usually of 1 kGy). The dose-effect curve is back-extrapolated and the initial given dose determined. At the Istituto Superiore di Sanita (ISS), Rome, Italy, a research programme was approved two ...

1996-12-31

231

The influence of electron-beam irradiation on some mechanical properties of commercial multilayer flexible packaging materials  

International Nuclear Information System (INIS)

The influence of electron-beam irradiation on mechanical properties of commercial multilayer flexible packaging materials based on coextruded and laminated polypropylene (PP), low-density polyethylene (LDPE), ethylene vinyl alcohol copolymer (EVOH) and poly(ethylene terephthalate) (PET), irradiated with doses up to 120 kGy, was studied. The tensile strength and elongation at break of the irradiated PET/PP film increase, while the penetration and sealing resistance decreased. In addition, the irradiated PET/LDPE/EVOH/LDPE film presented increase in the tensile strength on some radiation doses and decrease of the penetration and sealing resistance, except for sealing resistance at radiation dose of 15 kGy that resulted in a slight increase of ca 4%.

2008-09-21

232

Detection of irradiated chicken by ESR spectroscopy of bone  

Energy Technology Data Exchange (ETDEWEB)

Ionizing radiation has been used to treat poultry to remove harmful microorganisms, mainly Salmonella, which contaminates chicken, goose and other fresh and frozen poultry. This microorganism is sensitive to low dose radiation. Thus, irradiating these foods with doses between 1 to 7 kGy results in a large reduction of bacteria. Since it is necessary to determine whether irradiation has occurred and to what extend, this work studied the signal produced by ionizing radiation within the hard crystalline matrix of chicken`s bone to establish a control method. Chicken`s drumsticks were irradiated and bones separated from flesh were lyophilized and milled. ESR spectrum was then obtained. The ESR signal increased linearly with dose over the range 0.25 to 8.0 kGy. Free radicals evaluated during 30 days after irradiation showed stable in this period. ...

1995-10-01

233

Radiation resistance of nylon. [Gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

Various nylons including nylon 6, nylon 66, nylon 610 and nylon 12 in the forms of fiber and film were irradiated with the gamma-ray from Co-60 at the dose rate of 0.12 Mrad/hr in the atmosphere of oxygen at 7 kg/cm/sup 2/ and at the room temperature. The irradiation in vacuum on the same specimens was performed at 0.5 Mrad/hr. The tensile properties and the gel fraction of the irradiated nylon samples were measured, and the radiation resistance of the nylons against the irradiation at low dose rate was estimated. From the experimental results, it became clear that in the case of irradiation in vacuum, all the nylons were durable to the irradiation of 250 Mrad or more, and nylon 6 was more durable than nylon 12, and in the case of irradiation in pressurized oxygen, the radiation resistance of the ...

1983-12-01

234

Effects of ionizing radiation on properties of monolayer and multilayer flexible food packaging materials  

International Nuclear Information System (INIS)

Volatile compounds produced in flexible food packaging materials (LDPE, EVAc, PET/PE/EVOH/PE) during electron beam irradiation were isolated by purge and trap technique and identified by combined gas chromatography-mass spectrometry (GC/MS), after thermal desorption and concentration. For comparison purposes non-irradiated films were also studied. Film samples were irradiated at low (5 kGy, corresponding to cold pasteurization), intermediate (20 kGy, corresponding to cold sterilization) and high (100 kGy) doses. It was observed that a number of volatile compounds are produced after irradiation in all cases. Furthermore the amounts of all volatile compounds increase with increasing irradiation dose. Both primary (methyl-derivatives etc.) as well as secondary i.e. oxidation products (ketones, aldehydes, alcohols, carboxylic acids etc.) are ...

1999-05-01

235

Effect of gamma irradiation on the antimicrobial and free radical scavenging activities of Glycyrrhiza glabra root  

International Nuclear Information System (INIS)

The efficacy of gamma irradiation as a method of decontamination for food and herbal materials is well established. In the present study, Glycyrrhiza glabra roots were irradiated at doses 5, 10, 15, 20 and 25 kGy in a cobalt-60 irradiator. The irradiated and un-irradiated control samples were evaluated for phenolic contents, antimicrobial activities and DPPH scavenging properties. The result of the present study showed that radiation treatment up to 20 kGy does not affect the antifungal and antibacterial activity of the plant. While sample irradiated at 25 kGy does showed changes in the antibacterial activity against some selected pathogens. No significant differences in the phenolic contents were observed for control and samples irradiated at 5, 10 and 15 kGy radiation doses. However, phenolic ...

2010-04-01

236

Thermo-transferred thermoluminescence (TTTl) in potassium-yttrium double fluoride doped with terbium  

International Nuclear Information System (INIS)

This paper presents results of studying the thermo-transferred thermoluminescence (TTTl) phenomenon in potassium-yttrium double fluoride doped with terbium (K_2YF_5_:Tb) at different impurity concentrations (0.8%, 0.95% and 0.99%). Previously to study the TTTl phenomenon, structural characterization and chemical composition of the materials were determined. The structural studies were conducted using a scanning electron microscope; meanwhile, chemical composition was analyzed using energy dispersive X-ray spectroscopy. Thermoluminescence kinetics was studied irradiating the samples with "1"3"7Cs gamma rays as well as with "9"0Sr/"9"0Y beta rays, analyzing the glow curves by the deconvolution method for obtaining the kinetic parameters. (Author)

2011-02-01

237

Radiation treatment of medical devices and packaging materials. Pt. 1  

International Nuclear Information System (INIS)

The first part of the study contains a literature compilation of more than 50 original publications reporting the radiation induced effects in 17 different high polymer materials and glass which are relevant in the manufacturing of medical devices or packing materials. The results collected demonstrate that high energy radiation, i.e. gamma- or X-rays, causes various physical and chemical alterations in high polymer materials. A detailed summary and discussion of the results of the original publications is not included in the present report, it will be presented in the second part of the study. Furthermore, the second part of the study will refer to the aspect of wholesomeness of irradiated medical devices or packing materials in a more general manner of representation. (orig.).

238

Investigation on corrosion resistance of amorphous films prepared by ion beam mixing  

International Nuclear Information System (INIS)

Fe-Cr amorphous films have been formed by both in situ evaporation of multilayered films and ion beam mixing in a target chamber of a 200 keV implanter. The effects of Cr content and ion irradiation on the amorphization of films were examined by transmission electron microscope (TEM). Corrosion of film was investigated by means of a potential dynamic polarization. Corrosion resistance of amorphous film in 0.5 mol H-2SO-4 solution is considerably increased than that of pure iron. Using X ray photoelectron spectroscopy (XPS) corrosion resistance in atmosphere of amorphous Fe-Cr passive films formed by P"+ mixing was studied. Results show that the richness of Cr and P exist at the surface of Fe-Cr film.

1991-01-01

239

Electron Beam and Gamma Radiolysis of Solid-State Metoclopramide  

British Library Electronic Table of Contents (United Kingdom)

Purpose Study the radiolysis of solid-state metoclopramide hydrochloride at various absorbed doses. Elucidate the structure of the degradation products to gain information on the radiolysis mechanisms. Methods Solid-state metoclopramide samples were irradiated at several doses with gamma rays and high-energy electrons to evaluate the influence of the dose rate. High-performance liquid chromatography with a diode array detector was used to measure the chemical potency as a function of the absorbed dose and to quantify the degradation products. The characterization of degradation products was performed by liquid chromatography/atmospheric pressure chemical ionization/tandem mass spectrometry. Results The degradation of solid-state metoclopramide after irradiation was negligible. No qualitati...

2006-01-01

240

Infrared stimulated luminescence-decay shape from NaCl as a function of radiation doses  

Energy Technology Data Exchange (ETDEWEB)

Dose-dependent behavior of the infrared stimulated luminescence (IRSL) decay from NaCl has been studied experimentally using only one aliquot irradiated with a range of 2-200 Gy {beta}-radiation doses. It was observed that the maximum IRSL intensity has not changed by an increase in dose though the total intensity increased as expected. Considering the possible implications of our findings for dosimeter, the results were compared with the other studies and discussed.

2007-11-15

241

Development of detection methods for irradiated foods; development of immunological identification of irradiated foods  

Energy Technology Data Exchange (ETDEWEB)

Enzyme-linked Immunosorbent assay systems for the identification of irradiated egg, pork and chicken was developed. Eggs were irradiated in their shells to 0.5{approx}7kGy. Pork was irradiated to 0.5{approx}3kGy and chicken irradiated to 0.5kGy{approx}5kGy. The most sensitive proteins to irradiation were screened by SDS-PAGE and purified. Ovalbumin from egg, salt soluble protein(p) from pork, and salt soluble protein(c) from chicken showed the most sensitivity to irradiation. To investigate for a practical use in identifying of irradiated egg, pork and chicken, competitive ELISA was performed. The binding activity of ovalbumin to anti-ovalbumin IgG was reduced in a dose-dependent manner by irradiating up to 7kGy, and considerably lowered after irradiating at 7kGy. The ...

2002-04-01

242

The surface modification of tooth dentine with a Free Electron Laser (FEL)  

International Nuclear Information System (INIS)

Free Electron Laser (FEL) with the wide wavelength tunability has been developed and used for various applications. The FEL gives high efficiency for the photo-induced ablation when the laser is tuned to an absorption maximum of the target. The FEL was tuned to 9.4 #mu#m, which is an absorption maximum of phosphoric acid ion, a known major component of dentine. The FEL pulse length was several ps. The average output power was varied from 5 to 20 mW by filters. The change of irradiated dentine surface was analyzed by mass spectroscopy and Energy Dispersive X-ray (EDX) spectroscopy. Positive ions which correspond to Na"+, CO_3"+ and many phosphoric acid ions were measured. It was found that atomic ratio of P/Ca had reduced from 0.65-0.60. The atomic ratio of P/Ca, however had not changed with irradiation by Er:YAG laser (2.9 #mu#m), or CO_2 laser (10.6 #mu#m). These results indicate the selective ablation of phosphoric acid ...

1998-09-02

243

Magnetic imaging of ion-irradiation patterned Co/Pt multilayers using complementary electron and photon probes  

Energy Technology Data Exchange (ETDEWEB)

The three-dimensional magnetic structure and reversal mechanism of patterned Co/Pt multilayers, were imaged using complementary Lorentz transmission electron microscopy (LTEM) (in-plane component) and magnetic transmission x-ray microscopy (M-TXM) (perpendicular magnetization). The Co/Pt films with perpendicular anisotropy were patterned by ion irradiation through a stencil mask to produce in-plane magnetization in the irradiated regions. The boundaries of the patterns, defined by the transition from out-of-plane to in-plane magnetization, were found to be determined by the stencil mask, whilst the scale of the magnetic reversal by the physical microstructure. The nucleation fields were substantially reduced to 50 Oe for the in-plane regions and 1 kOe for the perpendicular regions, comparing to 4.5 kOe for the as-grown film. The perpendicular reversals were found to always originate at the pattern boundaries.

2001-04-01

244

Effective dose equivalent concept in radiopharmaceutical dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body ...

1981-06-01

245

Effective dose equivalent concept in radiopharmaceutical dosimetry  

International Nuclear Information System (INIS)

The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body ...

246

Stabilization of synchrotron radiation x-ray beam by MOSTAB  

International Nuclear Information System (INIS)

Monochromator stabilization (MOSTAB) is a feedback control system to stabilize an x-ray beam of synchrotron radiation. It applies a feedback voltage to a piezo electric transducer attached to a double-crystal monochromator. We developed MOSTAB modules and examined their performances using SPring-8 beamlines. The x-ray beam position stabilization using MOSTAB was realized simultaneously with the x-ray beam intensity stabilization. As an example of its application, we performed EXAFS measurement with MOSTAB. (author)

2003-05-01

247

Spin evolution in wind-fed X-ray binaries  

International Nuclear Information System (INIS)

Global angular momentum balance suggests that the neutron stars in Be/X-ray binaries are not spinning in equilibrium. This requires an X-ray lifetime ''approx <'' 10"5 yr, and suggests that there are many 'dead' Be/X-ray binaries in the Galaxy. Some of these may be turned up as millisecond radio pulsars with Be star companions. (author).

253

Radionuclide X-ray fluorescence analysis. 3: Examples of application in practice  

Science.gov (United States)

Examples are given of the applicability and importance of radionuclide fluorescence analysis as a

1973-01-01

254

Radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Slovak 1973. 164 p. Czechoslovakia Havranek, E. Bumbalova, A. Svitel,

1973-01-01

255

Possibilities of rayleigh-taylor instability measurement by X-ray phase imaging  

International Nuclear Information System (INIS)

X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging

256

NONDESTRUCTIVE DETERMINATION OF AIRBORNE LEAD ...  

Science.gov (United States)

... NONDESTRUCTIVE DETERMINATION OF AIRBORNE LEAD PARTICULATES BY THE RADIONUCLIDE X-RAY FLUORESCENCE ANALYSIS. ...

258

Investigation of morphology and chemical composition of self-organized semiconductor quantum dots and wires by X-ray scattering  

International Nuclear Information System (INIS)

X-ray scattering methods suitable for the investigation of the morphology and chemical composition of self-organized quantum dots and quantum wires are reviewed. Their application is demonstrated in experimental examples showing that a combination of small angle X-ray scattering with high-resolution X-ray diffraction can reveal both the shape and the chemical composition of the self-organized objects. (author)

2001-09-23

259

Ectopic Ureter  

Science.gov (United States)

... such as renal flow scan or a formal kidney X-ray, called an intravenous pyelogram ( IVP ), may help ...

263

The sensory quality of irradiated breaded poultry products  

International Nuclear Information System (INIS)

The colour, odour, flavour and texture of a breaded turkey escalope irradiated at doses of 2 and 4 kGy was assessed using a trained sensory panel. Irradiation did not affect raw appearance but during storage the irradiated breaded products became paler than the control samples. The off odour of the raw irradiated products was stronger than that of the unirradiated samples. Irradiation also affected the odour, flavour and texture of the cooked products. Although the trained panelists were able to detect significant differences between irradiated and unirradiated breaded turkey escalopes, the numerical differences between treatments were often quite small. It is possible that an untrained consumer group would be unable to detect these differences. Further research is needed with consumer groups to establish if irradiated ...

1994-07-01

264

Preparation of polyester/gypsum/composite using gamma radiation, and its radiation stability  

Energy Technology Data Exchange (ETDEWEB)

Composites based on pure gypsum and polyester-styrene resin have been prepared using various doses of gamma radiation. Some physical properties of the prepared composites and the influence of irradiation dose on it have been studied as: compression strength, hardness, thermal decomposition temperature in nitrogen or oxygen, and the change in weight in aqueous solutions with different pH values. The glass transition temperature of the pure polymer and the composites increases with increasing the irradiation dose up to a plateau, and the glass transition temperature of the pure polymer is lower than that of the composites. The irradiation dose does not seem to affect the decomposition temperature of the pure polymer or the composites significantly and the decomposition temperature in presence of nitrogen is higher than that in presence of ...

2005-06-01

265

High-dose neutron-irradiation effects in fcc metals at 4.6 K  

International Nuclear Information System (INIS)

The rate of residual-resistivity increase and the isochronal recovery have been studied on the fcc metals Al, Ni, Cu, Pd, Ag, Pt, and Au irradiated at 4.6 K with reactor neutrons to a dose of about 10"1"9 (fast neutrons)/cm"2. The rate of resistivity increase is nonlinear as a function of irradiation-induced resistivity; computer analysis shows that the data are best fitted with an erxpression having up to third-order terms in #DELTA#rho. There are deviations from simple damage-rate theory in all cases, but an anomalous negative deviation from a linear law (convex curvature) is observed in Ni, Pd, Pt (and Fe). This behavior is most probably caused by a decrease of the specific Frenkel-defect resistivity due to defect clustering, an effect which should contribute in all metals after fast-neutron irradiation to high doses. Saturation values of resistivity and defect concentration as ...

1977-12-01

266

Estimation of dose in irradiated chicken bone by ESR method  

Energy Technology Data Exchange (ETDEWEB)

The author studied the conditions needed to routinely estimate the radiation dose in chicken bone by repeated re-irradiation and measuring ESR signals. Chicken meat containing bone was {gamma}-irradiated at doses of up to 3kGy, accepted as the commercially used dose. The results show that points in sample preparation and ESR measurement are as follows: Both ends of bone are cut off and central part of compact bone is used for experiment. To obtain accurate ESR spectrum, marrow should be scraped out completely. Sample bone fragments of 1-2mm particle size and ca.100mg are recommended to obtain stable and maximum signal. In practice, by re-irradiating up to 5kGy and extrapolating data of the signal intensity to zero using linear regression analysis, radiation dose is estimated. For example, in one experiment, estimated ...

1998-03-01

267

Ultrastructural effect of gamma radiation on grass shrimps (Penaeus monodon Fabricius)  

Energy Technology Data Exchange (ETDEWEB)

The effect of ionizing radiation (2, 5, and 10 KGy of gamma rays) on muscle ultrastructure of grass shrimps (Penaeus monodon Fabricius) tails at ambient or frozen (-18{sup 0}C) temperature was investigated by transmission electron microscopy (TEM). No significant change was found in muscle ultrastructure of shrimp meat irradiated at doses of 2 or 5 KGy and then stored at 4{sup 0}C for 0 and 8 days. However, in shrimps which were irradiated at ambient temperature at a dose of 10 KGy, the margin of A-band of the myofibrils in longitudinal sections exhibited an irregular zig-zag pattern. In cross section some myosin filaments in the A-band regions were missing. A possible interpretation of these results would be that 10 KGy gamma irradiation dose at ambient temperature depolymerized myosin in the A-band from the tail of thick filament. Actin damage was also ...

1990-01-01

268

Ultrastructural effect of gamma radiation on grass shrimps (Penaeus monodon Fabricius)  

International Nuclear Information System (INIS)

The effect of ionizing radiation (2, 5, and 10 KGy of gamma rays) on muscle ultrastructure of grass shrimps (Penaeus monodon Fabricius) tails at ambient or frozen (-18"0C) temperature was investigated by transmission electron microscopy (TEM). No significant change was found in muscle ultrastructure of shrimp meat irradiated at doses of 2 or 5 KGy and then stored at 4"0C for 0 and 8 days. However, in shrimps which were irradiated at ambient temperature at a dose of 10 KGy, the margin of A-band of the myofibrils in longitudinal sections exhibited an irregular zig-zag pattern. In cross section some myosin filaments in the A-band regions were missing. A possible interpretation of these results would be that 10 KGy gamma irradiation dose at ambient temperature depolymerized myosin in the A-band from the tail of thick filament. Actin damage was also observed in some ...

269

Report of the IPSM working party on low- and medium-energy x-ray dosimetry  

Energy Technology Data Exchange (ETDEWEB)

New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).

1991-08-01

270

Report of the IPSM working party on low- and medium-energy x-ray dosimetry  

International Nuclear Information System (INIS)

New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).

1991-01-01

271

Reference values for X-ray diagnostic investigations. Some thoughts on the relation between expenditure and benefit; Referenzwerte fuer roentgendiagnostische Untersuchungen. Teil 2. Ueberlegungen zur Verhaeltnismaessigkeit von Nutzen und Aufwand  

Energy Technology Data Exchange (ETDEWEB)

In the first part of this contribution, the definition of reference values is given and the theoretical and practical problems in the application of this concept are discussed. In this connection, the present resources on instrumentation and the technical requirements for dose assessment are described. In the second part, some consequences are taken and proposals for further actions are made. (orig.) [German] Im ersten Teil des Aufsatzes werden Definitionen von Referenzwerten in der radiologischen Diagnostik untersucht und die theoretischen und praktischen Probleme der Umsetzung des gesamten Konzepts eroertert. In diesem Zusammenhang werden auch der gegenwaertige Geraetebestand und die technischen Voraussetzungen zur Dosisermittlung beschrieben. Im zweiten Teil werden daraus Schlussfolgerungen gezogen und Vorschlaege zum weiteren Vorgehen gemacht. (orig.)

2001-07-01

272

Reference values for X-ray diagnostic investigations. Some thoughts on the relation between expenditure and benefit; Referenzwerte fuer roentgendiagnostische Untersuchungen. T. 1. Ueberlegungen zur Verhaeltnismaessigkeit von Nutzen und Aufwand  

Energy Technology Data Exchange (ETDEWEB)

In the first part of this contribution, the definition of reference values is given and the theoretical and practical problems in the application of this concept are discussed. In this connection, the present resources on instrumentation and the technical requirements for dose assessment are described. In the second part, some consequences are taken and proposals for further actions are made. (orig.) [German] Im ersten Teil des Aufsatzes werden die Definition von Referenzwerten in der radiologischen Diagnostik untersucht und die theoretischen und praktischen Probleme der Umsetzung des gesamten Konzepts eroertert. In diesem Zusammenhang werden auch der gegenwaertige Geraetebestand und die technischen Voraussetzungen zur Dosisermittlung beschrieben. Im zweiten Teil werden daraus Schlussfolgerungen gezogen und Vorschlaege zum weiteren Vorgehen gemacht. (orig.)

2000-07-01

273

Electronics Personal Dosemeter (EPD-N) Test and Evaluation Report  

Energy Technology Data Exchange (ETDEWEB)

Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization then used at another site.

2003-04-08

274

Effect of treatment of Bis(3-triethoxysilyl propyl)tetrasulfane on physical property of in situ sodium activated and organomodified bentonite clay - SBR rubber nanocomposite  

British Library Electronic Table of Contents (United Kingdom)

This study describes the effect of treatment of Bis(3-triethoxysilyl propyl)tetrasulfane (silane coupling agent, Si69, TESPT) on in situ sodium activated, organo modified bentonite clay - styrene butadiene rubber (SBR) nanocomposite. transmission electron microscopy and Wide angle X-ray diffraction indicated the intercalation as well as partial exfoliation in both the organoclay and silane treated organoclay compound. It was found that about 5% of silane with respect to clay was the optimum dose for the treatment. Around 15% improvement in tensile and tear strength was observed due to silane treatment. Silane treated organoclay exhibited substantial improvement of the fatigue life, compression set, and rebound property. A detailed study of physical property was carried out. A comparison wi...

2010-01-01

275

Natural background radiation induces cytogenetic radioadaptive response more effectively than occupational exposure in human peripheral blood lymphocytes  

Science.gov (United States)

Ramsar, a city in the northern Iran, has the highest level of natural background radiation in the world. It has been clearly shown that low doses of ionising radiation can induce resistance to subsequent higher exposures. This phenomenon is termed radioadaptive response. We have compared induction of cytogenetic radioadaptive response by High Natural Background Radiation (HNBR) in Ramsar and X-ray occupational exposure as conditioning doses in human peripheral blood lymphocytes. 30 healthy control individuals, living in Ramsar but in normal background radiation areas, 15 healthy individuals from Talesh Mahalleh, a region with extraordinary high level of background radiation, and 7 X-ray radiographers working in Ramsar hospital located in normal natural background ionising radiation area were evaluated. Peripheral blood samples were prepared and exposed to challenge dose of 0 and 2 ...

2003-01-01

276

Are Optically-Selected Quasars Universally X-Ray Luminous? X-Ray/UV Relations in Sloan Digital Sky Survey Quasars  

CERN Document Server

We analyze archived Chandra and XMM-Newton X-ray observations of 536 Sloan Digital Sky Survey (SDSS) Data Release 5 (DR5) quasars (QSOs) at 1.7 <= z <= 2.7 in order to characterize the relative UV and X-ray spectral properties of QSOs that do not have broad UV absorption lines (BALs). We constrain the fraction of X-ray weak, non-BAL QSOs and find that such objects are rare; for example, sources underluminous by a factor of 10 comprise $\\la$2% of optically-selected SDSS QSOs. X-ray luminosities vary with respect to UV emission by a factor of $\\la$2 over several years for most sources. UV continuum reddening and the presence of narrow-line absorbing systems are not strongly associated with X-ray weakness in our sample. X-ray brightness is significantly correlated with UV emission line properties, so that relatively X-ray weak, non-BAL ...

2008-01-01

277

Studies on inherited sterility induced in the progeny of gamma irradiated cotton leaf worm, Spodoptera littorals (Boisd.)  

International Nuclear Information System (INIS)

Full - grown pupae of the cotton leaf worm Spodoptera littorals (Boisd.) were gamma - irradiated with low doses of 25,50,75, or 100 Gy for male line and with 50 or 100 Gy for female line . The effects on reproduction, development and sex ratio were the biological aspects studied among P1,F1,F2 and F 3 generations . Also, the effects of dose accumulation applied grown male pupae through two or three filial generations and the retarded influence on their F1,F2,and F 3 progeny were examined. In another trial the histological examinations for ovaries and testes of irradiated parents and for their generation were made . The F1 males were more sterile than irradiated parental males while F1 females were more fertile than their irradiated parental females. Irradiation of P1 males did not clearly affect neither the percentage of mated females nor ...

278

Inherited sterility induced in progeny of gamma irradiated males and females spiny bollworm, Earias Insulana boisd ,effect on fecundity, fertility and mating  

International Nuclear Information System (INIS)

adult males and females, less than 24 hours old, of the spiny bollworm, Earias Insulana boisd. were irradiated with sub sterilizing doses of 50,80,100 and 150 gray (Gy). treated moths were out crossed with normal adults and observed for their ability to reproduce. inherited deleterious effects resulting from irradiation of p_1 moths were recorded for several generations. the reduction in both fecundity and egg viability increased by increasing the dose applied to p_1 adult moths .at all tested doses, the females were more radiosensitive than males, as for reduction in fecundity and egg viability. the progeny from irradiated parental females are not as sterile as the progeny from irradiated parental males. the reduction of egg hatching continued in the progeny of irradiated males through F_1 and to lesser extent through ...

2004-02-01

279

Effects of gamma irradiation on the physical properties of laminated packaging materials. 2. polypropylene-polypropylene, polypropylene-polyethylene, and polyester-polyethylene  

International Nuclear Information System (INIS)

This experiment was done to determine the effects of irradiation on the physical properties of three kinds of laminated packaging materials, i.e. polypropylene-polypropylene, polypropylene-polyethylene, polyester-polyethylene. Observations were made on pinhole production, leakage, oil resistance, resistance against insect penetration, colour, odour tensile strength, elongation at break, seal strength and tear resistance. The samples were irradiated with doses of 0, 5 and 10 kGy, then stored at room temperature and examined after 0, 3, 6 and 12 months of storage. The results showed that irradiation doses up to 10 kGy, as well as storage up to 12 months, did not create pinholes, or leakage in pouches prepared from laminated films. The resistance of the films to oil and insect penetration, the colour, and the odour were also unchanged. Both irradiation and storage ...

280

Effects of gamma and electron beam irradiation on the properties of calendered cord fabrics  

Energy Technology Data Exchange (ETDEWEB)

The effects of gamma and e-beam irradiation on mechanical and structural properties of nylon 66 (Ny 66), nylon 6 (Ny 6) and poly(ethylene terephthalate) (PET) fabrics used in tyres were investigated. The untreated (greige), treated cords and calendered fabrics were irradiated at different doses. It is found that the effects of high energy irradiation on greige, treated cords and calendered fabrics are similar. No protective effect of compounds used in calendering was observed against radiation-induced oxidative degradation. The deterioration effect of gamma irradiation on mechanical properties is much higher than that of e-beam irradiation for all types of samples. Limiting viscosity numbers of both gamma and e-beam irradiated nylon 6 and nylon 66 cords were found to decrease with increasing dose. It is concluded that ...

2010-03-15

281

Neutron irradiation effects in austenitic alloys  

International Nuclear Information System (INIS)

The post (neutron) -irradiation high-temperature tensile and creep-rupture properties, deformation and fracture characteristics of austenitic alloys, particularly solution annealed Type 316 steel, are surveyed and correlated with the damage structures developed as a function of irradiation temperature (and dose). The mechanisms proposed to explain the irradiation-induced changes in properties and behaviour are summarised. The factors responsible for the observed differences in the post-irradiation and 'in-reactor' creep-rupture properties and behaviour of an austenitic steel are discussed in terms of the helium gas and stress driven growth of small intergranular bubbles and the atom plating associated with their growth and coalescence. (author).

1980-03-01

282

Experience in using Fuji computed radiography (FCR), 1  

Energy Technology Data Exchange (ETDEWEB)

New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey meter. The results obtained were as follows: 1) By using FCR system the radiation ...

1984-12-01

283

Experience in using Fuji computed radiography (FCR), 1  

International Nuclear Information System (INIS)

New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey meter. The results obtained were as follows: 1) By using FCR system the radiation ...

1984-01-01

284

Radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The author's achievements in the title field are summarized and discussed. The following topics are dealt with: (i) principles of radionuclide X-ray fluorescence analysis; (ii) mathematical methods in X-ray fluorescence analysis; (iii) Ross differential filters; (iv) application of radionuclide X-ray fluorescence analysis in the coal industry (with emphasis on the determination of the ash content, sulfur content, and arsenic content of coal); and (v) evaluation of the X-ray fluorescence analyzer from the radiological safety point of view. (P.A.).

1994-01-01

285

Future of X-ray phase imaging in medical imaging technology  

International Nuclear Information System (INIS)

Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)

2007-04-01

286

Determination of ash content in coal by means of backscattered X-ray radiation and X-ray fluorescence analysis, and devices manufactured by the PAR company  

Energy Technology Data Exchange (ETDEWEB)

Discusses methods for determining ash content in coal using backscattering in X-ray fluorescence. The following aspects are evaluated: principle of ash content determination, energy sources, factors that influence measurement accuracy, reliability. Types of X-ray fluorescence analyzers developed in Czechoslovakia and manufactured in the Czech Republic are comparatively evaluated. Operation of the RPM 113.1 radionuclide X-ray fluorescence analyzer developed by the PAR company and used for measuring ash content in coal and coal calorific value is discussed. 7 refs.

1993-09-01

287

An Apparent Hard X-ray Decline of CH Cygni  

CERN Document Server

CH Cygni is a symbiotic star consisting of an M giant and an accreting white dwarf, which is known to be a highly variable X-ray source with a complex, two-component, spectra. Here we report on two Suzaku observations of CH Cyg, taken in 2006 January and May, during which the system was seen to be in a soft X-ray bright, hard X-ray faint state. Based on the extraordinary strength of the 6.4 keV fluorescent Fe K-alpha line, we show that the hard X-rays observed with Suzaku are dominated by scattering.

2006-01-01

288

Effect of X- and gamma-rays on phenolic compounds from Maytenus aquifolium Martius  

International Nuclear Information System (INIS)

The effect of irradiation using several doses of X- and #gamma#-rays (10, 20, 40, 60, 80 and 100 kGy), upon total phenolic compounds contained in the leaves of Maytenus aquifolium Martius (Celastraceae) 'espinheira santa', was investigated. The content of phenolic compounds (measured by the Folin-Denis spectrophotometric method) was unaffected by X- or #gamma#-ray irradiation, at any dose. (author)

2005-06-01

289

Method of risk estimates for genetic, leukemogenic and carcinogenic effects from medical and occupational exposures  

International Nuclear Information System (INIS)

For the risk estimate of fatal malignancies, an effective dose was proposed on the basis of the assumption that the risk should be equal whether the whole body irradiated uniformly or whether there is non-uniform irradiation. The effective dose was defined by the product of organ or tissue doses and a weighting factor representing the proportion of risk factor for a fatal malignancy resulting from organ or tissue irradiation to the total malignant factor. The risk of malignancies can be derived by multiplying the malignant significant factor by the product of the risk factor and the effective dose. For the genetic risk, a significant factor was a relative child expectancy and organ or tissue doses were gonad doses. And, for the leukemogenic risk, a significant factor was the leukemia significant ...

1980-01-01

290

Luminescence Properties of ScPO{sub 4} Single Crystals  

Energy Technology Data Exchange (ETDEWEB)

Flux-grown ScPO{sub 4} single crystals exhibit a number of luminescence bands in their x-ray-excited luminescence spectra - including sharp lines arising from rare-earth elements plus a number of broad bands at 5.6 cV, 4.4 eV, and 3 eV. The band at 5.6 eV was attributed to a self-trapped exciton (STE) [l], and it could be excited at 7 eV and higher energies. This luminescence is strongly polarized (P = 70 %) along the optical axes of the crystal and exhibits a kinetic decay time constant that varies from several ns at room temperature to {approximately}10 {micro}s at 60 K and up to {approximately}1 ms at 10 K. It is assumed that the STE is localized on the SC ions. The band at 3 eV can be excited in the range of the ScPO{sub 4} crystal transparency (decay time = 3 to 4 {micro}s.) This band is attributed to a lead impurity that creates different luminescence centers. At high temperatures, the band at 4.4 eV is dominant in the x-ray-excited TSL ...

1999-08-16

291

Ionizing radiation effect on sealant properties  

International Nuclear Information System (INIS)

Presented are the investigation results of electrophysical and physico-mechanical properties of KLF-20, Viksint U-4-21, Viksint KT-73, UF-7-21, KG-184, KL-4, KL-16SE-305, VIAT-1 and PPK-21 sealants, irradiated with sources of continuous and pulse #gamma#-radiation, as well as pulse #gamma#-neutron radiation. It is shown that electrophysical and physico-mechanical properties of sealants after irradiation by continuous #gamma#-radiation up to 10"6 doses and pulse gamma-neutron radiation with neutron fluence of 10"1"3 neutron/cm"2 and #gamma#-radiation dose of 10"4R do not practically change. Electric conductivity and tangent of the angle of dielectric losses increase in the process of irradiation. Electric conductivity depends on irradiation type, is proportional to dose rate and does not depend on temperature and pulse duration.

292

Use of gamma irradiation for microbial inactivation of buckwheat flour and buckwheat food products, 6  

International Nuclear Information System (INIS)

The effects of gamma irradiation at 0.2#approx#0.4 Mrad and condition for processing of buckwheat noodles on sensory quality and physical properties were investigated. The results were as follows: (1) Sensory evaluation of buckwheat noodles, prepared with the 70 % ratio of buckwheat flour, was decreased according to an increase of irradiation dose of buckwheat flour. Hardness and adhesiveness of buckwheat noodles caused by irradiation should be given large effect to the texture. Elasticity of buckwheat noodles was linearly decreased with increasing of irradiation dose of buckwheat flour, and elasticity of buckwheat noodles was decreased about 15 % by an increase of irradiation dose at 0.3 Mrad. (2) Maximum torque in Farinograph test was linearly decreased with increasing of irradiation ...

1989-01-01

293

The effect of low dose gamma irradiation on the activity of blood serum lysozyme and complement in broiler chickens  

International Nuclear Information System (INIS)

Samples from 314 broiler chickens at 2 months age were analyzed for blood serum level of lysozyme and 311 of them were analyzed also for activity of alternative path-way of complement activity (APCA). Chickens were hatched from eggs, irradiated immediately before incubation with different doses of gamma-rays using Rocus M device - group 1 - control (non irradiated), and groups 2, 3 and 4 - irradiated with doses of 0.15, 0.30 and 0.60 Gy, respectively. Lysozyme concentration was highest for the control group, and for the experimental ones it was lower (p<0.001) which is an indication of the strongly negative effect of gamma-rays on this indicator. For APCA the oppsite relationship was observed - increasing of its activity with increasing of irradiation dose (from p<0.05 to p<0.001) which gave reason to suggest that this phenomenon is ...

294

Studies on radiation induced changes in bovine hemoglobin type A  

International Nuclear Information System (INIS)

In this paper the structural and functional changes of gamma irradiated bovine hemoglobin are presented. Aqueous solutions/1%/of HbO_2 were irradiated in air with doses ranging from 1 to 4 Mrad. Isoelectric focusing indicated change of the charge of irradiated hemoglobin. The isoelectric point of hemoglobin was displaced towards more acid values with increasing doses, up from 1 Mrad. Fingerprint analysis and peptide column chromatography of irradiated hemoglobin demonstrated disturbances increasing with the dose. These changes were confirmed by amino acid analysis which showed that Cys, Met, Trp, His, Pro and Tyr residues were destroyed or modified following irradiation. At doses exceeding 1 Mrad the irradiated solutions of hemoglobin showed a decrease of heme-heme interaction ...

295

Polymers and paper as packaging materials of irradiated food  

International Nuclear Information System (INIS)

Effects of #gamma#-irradiation on synthetic polymers and paper used as packaging materials for irradiated food have been studied by NMR. Polystyrene, polybutadiene and some copolymers were studied before and after the #gamma#-irradiation treatment and in the presence or absence of antioxidants and stabilisers. In the absence of additives, the effect of #gamma#-irradiation on polystyrene is negligible even irradiating at high doses. In turn, the role of antioxidants and stabilisers is crucial in polybutadiene and butadiene-containing copolymers. Wood pulp paper was also studied by NMR. Preliminary measurements on #gamma#-irradiated wood pulp sheets show a shortening in the T_2 relaxation time component due to the bound water, i.e. some of the bound water is lost. (author)

2000-03-01

296

Lipid composition of liver microsomes and mitochondria after acute and chronic {gamma}-irradiation of rats  

Energy Technology Data Exchange (ETDEWEB)

Acute {gamma}-irradiation of rats at doses of 100 and 270 Gy stimulates lipid synthesis and changes the lipid composition of liver cell organelles. The content of cholesterol and cholesterol esters in microsomes increased at 100 Gy and decreased at 270 Gy, with total phospholipid content remaining unchanged. The lipid content in mitochondria decreased considerably 1 h after irradiation at 270 Gy. This change was significantly less pronounced 47 h later. Under chronic {gamma}-irradiation (0.129 Gy/day), cholesterol and cardiolipin in mitochondria increased. The changes in lipid content caused by acute irradiation are presumed to be related to activated synthesis of lipids in the liver. The modification of the lipid content of mitochondria observed in chronically irradiated rats may indicate that energy-metabolizing liver cell systems are involved in the ...

1994-07-01

297

Properties and morphology of PMMA/ABN blends obtained via MMA in situ polymerisation through {gamma}-rays  

Energy Technology Data Exchange (ETDEWEB)

Methylmethacrylate polymerisation in the presence of 4 wt% butadiene-acrylonitrile rubber was carried out at fixed dose-rate and temperature. The effect of irradiation was investigated with respect to the mechanical and dynamic-mechanical properties in the solid state. A general increase of the 'compatibilisation' on irradiation is obtained. In fact both rubber and polymethylmethacrylate glass transition temperatures, determined through dynamic-mechanical analysis, reveal the presence of strong interactions between the components. Furthermore an improvement of the mechanical tensile properties of the blends is observed when irradiation is continued after polymerisation, at least until a certain absorbed dose.

2001-12-01

298

Integration of SPECT with CT to plan radiotherapy fields. n application to conformal irradiation for lung carcinoma  

International Nuclear Information System (INIS)

Single photon emission computed tomography (SPECT) of lung perfusions permits to map functioning lung parenchyma with higher sensitivity than CT. Delivering higher radiations doses it used to increase local control in lung carcinoma; this strategy is based on radiobiological and clinical studies. Lung parenchyma is a dose-limiting tissue in patients irradiated for lung cancer. Functional mapping based on SPECT and CT findings permits to design radiation beams such as to minimize irradiation of functioning lung.

1999-04-01

299

Patterns of proliferation and differentiation of irradiated haemopoietic stem cells cultured on normal 'stromal' cell colonies in vitro  

Energy Technology Data Exchange (ETDEWEB)

Experiments were designed to elucidate whether or not the irradiated bone marrow cells receive any stimulation for the self-replication and differentiation from normal 'stromal' cell colonies in the bone marrow cell culture in vitro. When irradiated or unirradiated bone marrow cells were overlaid on the normal adherent cell colonies, the proliferation of haemopoietic stem cells was supported, the degree of the stimulation depending on the starting cellular concentration. There was, however, no significant changes in the concentration of either CFUs or CFUc regardless of the dose of irradiation on the bone marrow cells overlaid. This was a great contrast to the dose-dependent decrease of CFUs or CFUc within the culture in which both the stem cells and stromal cells were simultaneously irradiated. These results suggest that the balance of ...

1981-09-01

300

A note on neutron irradiation effects on transition temperature of A-15 superconducting materials  

International Nuclear Information System (INIS)

The change of superconducting properties after neutron irradiation in A-15 compounds such as Nb_3Sn. Nb_3Al. V_3Ca and V_3Si has been examined. Using the model based on the damage function, the change of transition temperature corresponding to an arbitrary irradiation dose within about 10"2"0n/cm"2 can be predicted with an accuracy of several percent for Nb_3Al. Nb_3Sn and V_3Si if experimental data, namely a pair of irradiation dose and transition temperature, is given. The calculation of transition temperature of neutron irradiated A-15 compounds is much more straightforward than in the case of Pande's model. (author).

301

Preparation of pinewood/polymer/composites using gamma irradiation  

Energy Technology Data Exchange (ETDEWEB)

Wood/polymer composites (WPC) have been prepared from pinewood with different compounds using gamma irradiation: butyl acrylate, butyl methacrylate, styrene, acrylamide, acrylonitrile, and unsaturated polyester styrene resin. The polymer loading was determined with respect to the compound concentration and the irradiation dose. The polymer loading increases generally with increase in the monomer or polymer concentration. Tensile and compression strength have been improved in the four cases, but no improvement was observed using unsaturated polyester styrene resin or acrylamide.

2006-09-15

302

Effects of gamma irradiation on microbial contamination and extraction yields of Korean medicinal herbs  

Energy Technology Data Exchange (ETDEWEB)

Effects of gamma irradiation on hygienic quality and extraction yields in twenty-one kinds of Korean medicinal herbs were investigated. Gamma irradiation at 5-10 kGy inactivated contaminating microorganisms. The total extraction yield in fifteen kinds of the investigated medicinal herbs increased by 5-25% by a dose of 10 kGy. (author)

2000-01-01

303

Irradiation of spices, packaging materials and luncheon to improve the storability of the end product  

International Nuclear Information System (INIS)

Spices and packaging materials were exposed to gamma irradiation at a dose of 10 KGy. Luncheon was prepared with irradiated or non-irradiated spices. Prepared luncheon was packaged in irradiated or non-irradiated packaging materials. Packaged luncheon was treated with 2 KGy. Treated and untreated packaged luncheon were kept in a refrigerator (1-4 Centigrade) for 12 months. Microbiological, nutritive and chemical characteristics of luncheon were evaluated after processing and during storage; whereas, sensory quality was evaluated only after irradiation. Gamma irradiation decreased the microorganisms counts of spices, packaging materials and packed luncheon and increased the shelf-life of packaged luncheon products. No major differences in moisture, protein, fat, ph value, total acidity, lipid peroxide and volatile basic ...

304

Microstructural observation of focused ion beam modification of Ni silicides/Si thin films  

International Nuclear Information System (INIS)

Focused ion beam (FIB) irradiation of a thin Ni_2Si layer deposited on a Si substrate was carried out and studied using an in-situ transmission electron microscope (in-situ TEM). Square areas on sides of 4 by 4 and 9 by 9 microm were patterned at room temperature with a 25 keV Ga"+-FIB attached to the TEM. The structural changes of the films indicate a uniform milling, sputtering of the Ni_2Si layer and the damage introducing to the Si substrate. Annealing at 673 K results in the change of the Ni_2Si layer into an epitaxial NiSi_2 layer outside the FIB irradiated area, but several precipitates appear around the treated area. Precipitates was analyzed by energy dispersive X-ray spectroscopy (EDS). Larger amount of Ni than the surrounding matrix was found in precipitates. Selected area diffraction (SAD) patterns of the precipitates and the corresponding dark field images imply the formation of a Ni rich silicide. The relation ...

1996-12-02

305

Measuring instrument for radiometric monitoring of solids and heavy metals in water  

International Nuclear Information System (INIS)

A combination of measuring instruments, consisting of a Beta-Sedimeter and a radionuclide X-ray fluorescence instrument, is described. With the Beta-Sedimeter the C-14-radiation is measured. Through direct irradiation with photons of a Pu238-source in an ancillary irradiation chamber and energy dispersing measurement of the K- and L-radiation resp. of the excited heavy metals with the aid of a Si(Li)-semiconductor detector and a 4-channel analyzer the heavy metal concentrations of the heavy metals Zn, Cr, Ni and Pb are determined. For the determination of cadmium the indirect excitation with Am-241 and Dy-targets is described. The system produces records and operates fully automatically in a step-by-step mode with a testing cycle of 45 minutes. In connection with the process monitoring of the wastewater from a zinc plating plant during a period of 8 months the concentration of the solid material and of the metals Cr and Zn, ...

1979-01-01

306

Radiation induced synthesis of low molecular weight of PTFE and their crosslinking in acetone medium  

International Nuclear Information System (INIS)

Polytetrafluoroethylene was obtained by radiation induced polymerization of tetrafluoroethylene in acetone at 195 K. An average diameter of the products was very small compared with commercial one; it was about 0.3 micro-meters. The yield was reached to 100% with a dose of 4 kGy. The crystallinity of the products is decreasing with increasing dose. The products become amorphous, for higher irradiation doses. It was found that PTFE obtained by irradiation of TFE in acetone at 195 K has branching structure. This was demonstrated by means of "1"9F MAS NMR. (Author)

2007-09-03

307

On-line dosimetry for BNCT at the MIT research reactor  

Science.gov (United States)

A computer-based beam dosimetry measurement system for boron neutron capture therapy provides accurate, sensitive, and rapid readout and recording of all beam dose components, epithermal and thermal neutron flux, and gamma-ray dose rate. This dosimetric system includes input from the characterization of the epithermal neutron beam developed at the Massachusetts Institute of Technology, actual BPA pharmacokinetic data from a specific human subject being irradiated, output of MacNCTPLAN, a treatment planning system developed by the authors group, and input from the five on-line beam detectors. The purpose of this system and associated readout systems is to ensure that the desired dose is delivered to the subject within acceptable dose tolerances, e.g., {+-}5% of the target dose, and that any perturbations in the neutron beam that may occur during ...

1996-12-31

308

On-line dosimetry for BNCT at the MIT research reactor  

International Nuclear Information System (INIS)

A computer-based beam dosimetry measurement system for boron neutron capture therapy provides accurate, sensitive, and rapid readout and recording of all beam dose components, epithermal and thermal neutron flux, and gamma-ray dose rate. This dosimetric system includes input from the characterization of the epithermal neutron beam developed at the Massachusetts Institute of Technology, actual BPA pharmacokinetic data from a specific human subject being irradiated, output of MacNCTPLAN, a treatment planning system developed by the authors group, and input from the five on-line beam detectors. The purpose of this system and associated readout systems is to ensure that the desired dose is delivered to the subject within acceptable dose tolerances, e.g., #+-#5% of the target dose, and that any perturbations in the neutron beam that may occur during ...

1996-11-10

309

Broad-band hard X-ray reflectors  

DEFF Research Database (Denmark)

Interest in optics for hard X-ray broad-band application is growing. In this paper, we compare the hard X-ray (20-100 keV) reflectivity obtained with an energy-dispersive reflectometer, of a standard commercial gold thin-film with that of a 600 bilayer W/Si X-ray supermirror. The reflectivity of the multilayer is found to agree extraordinarily well with theory (assuming an interface roughness of 4.5 Angstrom), while the agreement for the gold film is less, The overall performance of the supermirror is superior to that of gold, extending the band of reflection at least a factor of 2.8 beyond that of the gold, Various other design options are discussed, and we conclude that continued interest in the X-ray supermirror for broad-band hard X-ray applications is warranted.

1997-01-01

310

Development of an irradiation system for a small size continuous run multipurpose gamma irradiator  

International Nuclear Information System (INIS)

The Radiation Technology Center from IPEN-CNEN/SP, Brazil, developed a revolutionary design and national technology, a small-sized continuous run and multipurpose industrial gamma irradiator, to be used as a demonstration facility for manufacturers and contract service companies, which need economical and logistical in-house irradiation system alternatives. Also, to be useful for supporting the local scientific community on development of products and process using gamma radiation, assisting the traditional and potential users on process validation, training and qualification of operators and radioprotection officers. The developed technology for this facility consists of a continuous tote box transport system, comprising a single concrete vault, where the automated transport system of products inside and outside of the irradiator utilizes a rotating door, integrated with the shielding, avoiding the traditional maze ...

311

Radiations emitted in the decay of /sup 165/Er: A promising medical radionuclide  

Science.gov (United States)

The 10.3-h /sup 165/Er, decaying by electron capture to stable /sup 165/Ho, offers an excellent promise for use in diagnostic nuclear medicine, especially in conjuction with multiwire proportional-counter cameras. Using an ultra-high-resolution Si(Li) photon spectrometer, L and K x-ray photon yields in /sup 165/Er decay have been measured. The ratio P/sub L//P/sub K/ of electron-capture probabilities in L and K shells is determined to be 0.196 +- 0.030, in good agreement with theory. Estimates of Auger electron yields and yields of very-low-energy electrons from Coster--Kronig transitions are presented. Levels of /sup 169/Er and /sup 171/Er radioactive impurities in the reactor-produced /sup 165/Er sample are experimentally determined. Whole-body dose estimates for /sup 165/Er are given. These compare favorably with /sup 99/Tc dose.

1977-05-01

312

Radiations emitted in the decay of "1"6"5Er: A promising medical radionuclide  

International Nuclear Information System (INIS)

The 10.3-h "1"6"5Er, decaying by electron capture to stable "1"6"5Ho, offers an excellent promise for use in diagnostic nuclear medicine, especially in conjuction with multiwire proportional-counter cameras. Using an ultra-high-resolution Si(Li) photon spectrometer, L and K x-ray photon yields in "1"6"5Er decay have been measured. The ratio P/sub L//P/sub K/ of electron-capture probabilities in L and K shells is determined to be 0.196 +- 0.030, in good agreement with theory. Estimates of Auger electron yields and yields of very-low-energy electrons from Coster--Kronig transitions are presented. Levels of "1"6"9Er and "1"7"1Er radioactive impurities in the reactor-produced "1"6"5Er sample are experimentally determined. Whole-body dose estimates for "1"6"5Er are given. These compare favorably with "9"9Tc dose.

313

Quantitative assessment of mineral content in metacarpal bone with Fuji computed radiography  

Energy Technology Data Exchange (ETDEWEB)

A new microdensitometry method for quantitative assessment of bone mineral content using Fuji computed radiography (FCR) was developed and the results were compared with those obtained by the conventional film-screen method. Using both methods, X-ray pictures of the 2nd metacarpal bone were taken with a reference aluminum step wedge in nine normal subjects and nine parameters representing the width and density of bone marrow and cortex were calculated in middle of the bone shaft. Interobserver reproducibility assessed for three parameters was significantly higher in the FCR method than the conventional one. The value of {Sigma}GS computed by the FCR method, that is equivalent to the net bone density of the transverse section of the shaft, showed higher correlation with the one obtained by computed tomography in comparison with the conventional method. In our FCR method, moreover, interobserver reproducibility and accuracy was improved by employing automatic ...

1990-05-01

314

Quantitative assessment of mineral content in metacarpal bone with Fuji computed radiography  

International Nuclear Information System (INIS)

A new microdensitometry method for quantitative assessment of bone mineral content using Fuji computed radiography (FCR) was developed and the results were compared with those obtained by the conventional film-screen method. Using both methods, X-ray pictures of the 2nd metacarpal bone were taken with a reference aluminum step wedge in nine normal subjects and nine parameters representing the width and density of bone marrow and cortex were calculated in middle of the bone shaft. Interobserver reproducibility assessed for three parameters was significantly higher in the FCR method than the conventional one. The value of #SIGMA#GS computed by the FCR method, that is equivalent to the net bone density of the transverse section of the shaft, showed higher correlation with the one obtained by computed tomography in comparison with the conventional method. In our FCR method, moreover, interobserver reproducibility and accuracy was improved by employing automatic ...

1990-01-01

315

Potassium deposition on a thiophene-terminated alkanethiol monolayer  

International Nuclear Information System (INIS)

Potassium deposition in ultrahigh vacuum on 12-(3-thienyl)dodecanethiol monolayers assembled on gold surfaces has been investigated using X-ray and ultraviolet photoelectron spectroscopies (XPS and UPS). Angle-resolved XPS indicates that initially deposited potassium penetrates the self-assembled monolayer (SAM) and diffuses to the SAM/Au interface. Even after large metal doses, the presence of thiophene ring valence electronic states in the UPS spectra confirms that most of the thiophene rings (at the SAM/vacuum interface) are not covered by potassium. The binding energy shifts of the thiophene ring valence states and the C1s and thiophene S2p peaks, referenced to the Fermi level, are due to the work function changes of the gold substrate. This indicates that these electronic states are pinned to the vacuum level, in contrast to the thiolate S2p orbital, which is pinned to the Fermi level. For large potassium doses, the ...

2009-05-01

316

Imaging properties of the Medipix2 system exploiting single and dual energy thresholds  

CERN Document Server

Low noise, high resolution and high dose efficiency are the common requirements for most X-ray imaging applications. Especially in medical applications the dose efficiency is a necessity for detector systems. We present the imaging performance of the Medipix2 readout chip bump bonded to a 300 mu m thick Si detector as a function of the detection threshold, a free parameter not available in conventional integrating imaging systems. Spatial resolution has been measured using the modulation transfer function (MTF) and it varies between 8.2 Ip/mm and 11.0 Ip/mm at 70%. An associated measurement of noise power spectrum (NPS) permits us to derive the detective quantum efficiency (DQE) which can be as a high as 25.5 % for a broadband incoming spectrum. The influence of charge diffusion in the sensor together with threshold variation in the readout chip is discussed. Although the Medipix2 system is used in photon counting mode with ...

2006-01-01

317

Target Diagnostic Instrument-Based Controls Framework for the National Ignition Facility  

Energy Technology Data Exchange (ETDEWEB)

NIF target diagnostics are being developed to observe and measure the extreme physics of targets irradiated by the 192-beam laser. The response time of target materials can be on the order of 100ps--the time it takes light to travel 3 cm--temperatures more than 100 times hotter than the surface of the sun, and pressures that exceed 109 atmospheres. Optical and x-ray diagnostics were developed and fielded to observe and record the results of the first 4-beam experiments at NIF. Hard and soft x-ray spectra were measured, and time-integrated and gated x-ray images of hydrodynamics experiments were recorded. Optical diagnostics recorded backscatter from the target, and VISAR laser velocimetry measurements were taken of laser-shocked target surfaces. Additional diagnostics are being developed and commissioned to observe and diagnose ignition implosions, including various neutron and activation diagnostics. ...

2007-05-07

318

The role of lesions of DNA in senescence of seeds of Lupinus polyphyllus L. induced by chronic low-intensity irradiation  

International Nuclear Information System (INIS)

A nonlinear relationship between the time of accelerated aging of Lupine seeds and the indices of its survival as well as the single-strand DNA amount in cells from these seeds is established. The character of this relationship is essentially altered in chronically irradiated lupine seeds from the Chernobyl NPP exclusion zone and seems more complicated. The possible role of repair systems in these effects is discussed. The fact that chronic irradiation in low doses can modify the course of senescence in lupine seeds reflects its high biological efficiency comparing with acute irradiation.

2000-08-01

319

The pharmacological activity of medical herbs after microbiological decontamination by irradiation  

Energy Technology Data Exchange (ETDEWEB)

In the Institute of Nuclear Chemistry and Technology research on microbiological decontamination of medicinal herbs by irradiation has been carried out since 1996. It was shown that using ionizing radiation (a dose of 10 kGy) can obtain satisfactory results of microbiological decontamination of these products. The content of essential biologically active substances such as essential oils, flavonoids, glycosides, anthocyans, antra-compounds, poliphenoloacids, triterpene saponins, oleanosides and plants mucus did not change significantly after irradiation. Pharmacological activity of medicinal herbs has been found satisfactory after microbiological decontamination by irradiation.

2000-03-01

320

Radiotherapeutic methods for Ewing's sarcoma of the long tubular bones in children  

International Nuclear Information System (INIS)

Radiotherapeutic results of the Ewing sarcoma of the long tubular bones in 140 pediatric patients aged 3-16 are analyzed with the respect to different methods of irradiation. Three-field irradiation, the fields being located at 120 deg to one another with daily irradiation of all three fields at a focal dose of 2 Gy, was found superior in treatment of primary neoplasm. It is stressed that the disease termination mainly depends on the efficiency of primary neoplasm treatment, as the neoplasm reccurence generally is followed by metastases. Radiation load is calculated for maximal irradiation area of soft tissues in children.

321

Irradiation of microbial controlling on package tofu  

International Nuclear Information System (INIS)

The effects of irradiation on microbiological controlling, nutrient and sensory qualities of packaged tofu (bean curd) stored at commercial condition. Results showed that D10 values of Listeria innocua and Samonella enteritidis inoculated in packaged tofu were 0.225 and 0.240kGy, respectively. Irradiation dose lower than 2.0kGy had no significant effects on content of crude protein and amino acid (p>0.05). ?-irradiation could decrease microbial in packaged tofu and 2.0kGy should be applied to ensure the hygienic quality of the products. (authors)

2009-08-01

322

Effects of gamma irradiation on the sperm transmission and oviposition response in Helicoverpa armigera (L. NOCTUIDAE)  

International Nuclear Information System (INIS)

Transmissions of sperm by unirradiated and irradiated cotton bollworm, Helicoverpa armigera, were studied by live dissection of females immediately after the initiation of mating. In cotton bollworm the sperm transfer was rather a complex process. In fact unirradiated males failed to transfer sperm in about 19% of their matings. When irradiated with 250 Gy and 400 Gy, aberrations of sperm transmission were about 21% and 50% respectively. The failure of spermatophore 'cap' location was an important reason of sperm transmission aberrations. When females mated to high-dose-irradiated males, their oviposition response appeared abnormal

2002-02-01

323

Computer-assisted rotation and multiple stationary irradiation technique  

International Nuclear Information System (INIS)

A computer-assisted rotation and stationary conformation radiotherapy system with overrunning multileaf collimators has been developed. This system can produce any shape of target volume, including a number of target areas outside the axis of the rotation, regardless of the location of the axis at 360"0 rotation irradiation. In addition, by changing the dose rate and deleting a partial region within a field, multiple stationary irradiation can produce more homogeneous target volumes - thus avoiding excessive irradiation to critical organs - than the rotation technique. (orig.).

324

Preliminary studies on the detection of irradiated prawns using 2-alkylcyclobutanones  

Energy Technology Data Exchange (ETDEWEB)

The use of ionising radiation for the preservation of food has been under investigation for many years but has yet to receive worldwide acceptance. Although irradiation can be carefully controlled, it is generally accepted that the development of a test or tests for the detection of irradiated food would enhance consumer confidence and might help to enforce labelling regulations. The 2-alkylcyclobutanones are reported to be the only cyclic compounds formed as the products of the radiolysis of saturated and unsaturated triglycerides. The synthesis of 2-dodecylcyclobutanone (DCB) and 2-tetradecylcyclobutanone (TCB), which are formed from palmitic and stearic acid respectively following irradiation, has been carried out and using irradiated chicken meat as the model for a high-lipid containing food, both cyclobutanones have been extracted with hexane and then identified using gas chromatography/mass ...

1996-12-31

325

Influence of gamma irradiation and storage on the microbial load, chemical and sensory quality of chicken kabab  

Energy Technology Data Exchange (ETDEWEB)

Influence of gamma irradiation and storage on the microbial load, chemical and sensory quality of chicken kabab was investigated. Chicken kabab was treated with 0, 2, 4 or 6 kGy doses of gamma irradiation. Treated and untreated samples were kept in a refrigerator (1-4 deg. C). Microbiological, chemical and sensory characteristics of chicken kabab were evaluated at 0-5 months of storage. Gamma irradiation decreased the microbial load and increased the shelf-life of chicken kabab. Irradiation did not influence the major constituents of chicken kabab (moisture, protein and fats). No significant differences (p>0.05) were observed for total acidity between non-irradiated (control) and irradiated chicken kabab. Thiobarbitric acid (TBA) values (expressed as mg malonaldehyde (MDA)/kg chicken kabab) and volatile basic nitrogen (VBN) in chicken ...

2010-08-15

326

Thermal expansion of gamma irradiated nylon 66 from 10 K to 340 K  

Energy Technology Data Exchange (ETDEWEB)

Samples of nylon 66 rods were irradiated using a cobalt-60 gamma ray source at a dose rate of 0.25 Mrad h[sup -1] in air at room temperature to a maximum dose of 500 Mrad. The linear coefficient of thermal expansion ([alpha]) was measured using a three-terminal capacitance technique reported previously. The variation of [alpha] with temperature between 10 K and 340 K was investigated for an unirradiated sample and two samples irradiated to 300 Mrad and 500 Mrad. In the range 10K to 160K, [alpha] is almost invariant with radiation dose and there is little difference between the values for the unirradiated and the 300 Mrad irradiated samples above 160 K. The sample irradiated to 500 Mrad does show a 6% increase in [alpha] over the other samples in the higher temperature range. All samples show an increase overall in the value of [alpha] with ...

1994-08-15

327

Effects of focused-ion-beam irradiation on perpendicular write head performance  

International Nuclear Information System (INIS)

The effects of focused-ion-beam (FIB) irradiation on writer performance were examined on a perpendicular recording system. The entire top pole was irradiated by FIB with ion doses from 0 to 300 pC/#mu#m"2. PW_5_0 and signal to noise ratio (SNR) were characterized using a spin stand before and after FIB irradiation. It was found that there is degradation of PW_5_0 and SNR due to FIB irradiation. At the maximum dose (300 pC/#mu#m"2), PW_5_0 increased by 33 nm (>30%) and SNR decreased by 5 dB (>25%). The degradation was attributed to the physical pole tip recession and the formation of a magnetic dead layer. The thickness of the magnetic dead layer was estimated by analyzing the write spacing loss. Using atomic force microscopy and stage current change monitored during FIB process, it was found that the entire 4-nm protective carbon layer was etched away with ...

2003-05-15

328

Adaptive response of the chicken embryo to low doses of x-irradiation  

Energy Technology Data Exchange (ETDEWEB)

Chicken embryos were x-irradiated in ovo with 5-30 cGy (=priming dose) at the 13th-15th day of development. After 3-48 h, brain- and liver-cell suspensions were x-irradiated in vitro with (challenge) doses of 4-32 Gy. Significantly less radiation damage was observed when the radiation response was measured by scheduled DNA synthesis, nucleoid sedimentation and viscosity of alkaline cell lysates 12-36 h after the priming exposure. In vivo, pre-irradiation with 10 cGy enhanced regeneration as evidenced by the DNA content of chicken embryo brain and liver 24 h following a challenge dose of 4 Gy. From nucleoid sedimentation analyses in brain and liver cells immediately after irradiation with 16 Gy and after a 30-min repair period in the presence of aphidicolin, dideoxythymidine and 3-aminobenzamide or in the absence of these DNA repair ...

1995-08-01

329

Chemical, sensory and microbiological changes of gamma irradiated coconut cream powder  

Energy Technology Data Exchange (ETDEWEB)

A study was carried out to determine optimum decontamination dose for a locally manufactured coconut cream powder. Samples were gamma irradiated (0-15 kGy) and ageing process was achieved using GEER oven at 60 deg. C for 7 days, which is equivalent to one-year storage at room temperature. Iodine value (IV), ranging from 4.8 to 6.4, was not affected by radiation doses and storage, however peroxide value and thiobarbituric acid (TBA) generally increased with radiation doses. In most samples, peroxide value (meq/kg) reduced after storage, whilst the TBA (mg malonaldehyde/kg), indicator for product quality, slightly increased. The sensory evaluation conducted using 25 taste panellists indicated that scores on odour, creamy taste and overall acceptance for all irradiated samples at more than 5 kGy were significantly lower (P<0.05) than the control. However, the panellists could ...

2007-11-15

330

Stem cell kinetics in spleen and bone marrow after single and fractionated irradiation of infant mice  

Energy Technology Data Exchange (ETDEWEB)

The number and type of stem cells in spleen and bone marrow of mice were determined after exposure to a single dose of 150 R on day 6, to a single dose of 500 R on day 6 or day 9 or to a fractionated dose of 150 R + 350 R on day 6 and 9. The stem cells were assayed on the basis of colony forming units (CFU) in spleen and of incorporation of iododeoxyuridine in spleen and bone marrow of lethally irradiated host mice. During the first month of life, the number of stem cells in non-irradiated mice increases markedly in bone marrow and slightly in spleen. Irradiation causes a long-lasting depression in stem cells, particularly in bone marrow and affecting preferentially erythropoietic precursor cells. Following a dose of only 150 R, the number of CFU in bone marrow is still below control levels 24 days later. An exposure to 500 R fractionated ...

1980-12-01

331

Anode length optimization in a modified plasma focus device for optimal x-ray yields  

International Nuclear Information System (INIS)

The effect of anode length and operating gas pressure on the x-ray emission from a nitrogen-filling modified plasma focus device has been investigated. The time-resolved investigation of x ray was carried out by using a five-channel photodiode x-ray spectrometer. The maximum x-ray yield is seen to increase with the increase in the anode length from 110 to 125 mm. Further increase in the anode length to 130 mm causes the x-ray yields to decrease. The highest x-ray yield of 4.5 J into 4#pi# sr was found for 125 mm anode length, which is 0.2% of the input energy. The average x-ray photon energy was estimated by using half-value thickness method and found to be 8.4 keV. The electron temperature of the plasma was estimated to be around 3 keV by x-ray intensity ratio method. The space-resolved ...

2006-01-01

332

A study of radiation embrittlement using simulation irradiation  

International Nuclear Information System (INIS)

Simulation irradiation experiments were carried out to investigate the formation processes and contribution to hardening of radiation-induced features in low alloy steels. Medium Cu (0.12 and 0.16%) and low Cu (0.03%) A533B steels were irradiated with 3 MeV Ni ions and 5 MeV electrons, and in KUR at 290degC. Irradiated steels were examined by three-dimensional atom probe, positron annihilation, high-resolution transmission electron microscopy and hardness measurements. Electron irradiation caused almost the same hardening as KUR irradiation in medium Cu steels under almost the same dose rate and dose conditions, whereas the formation of larger, denser and more Cu enriched clusters and smaller accumulation of single vacancies were confirmed for KUR irradiation. This indicated that cascade damage provides additional ...

2008-10-13

333

Studies on the biological effects of chemical defense mechanisms in vivo activated by low-dose irradiation  

International Nuclear Information System (INIS)

Active oxygens produced by low-dose irradiation can induce the synthesis of proteins involved in the active oxygen reduction path and can activate the chemical self-defense mechanisms in vivo, which can alleviate the injuries caused by active oxygens themselves. The following findings suggests that it is not only by low-dose irradiation that can induce the responses described above but also by any physical and/or chemical stresses which can produce small amount of active oxygens in vivo. 1. X-irradiation with 0.5 Gy and/or water immersion and restraint induced heat shock protein (HSP)70 in rat stomach cells. HSP70 was also induced in adrenal cells by paraquat administration. 2. The SOD activity in pancreas of rat significantly increased by #gamma#-irradiation with 0.5 Gy. 0.5 Gy irradiation preceeding the alloxan administration significantly ...

334

Radiolysis compounds in bacon and chicken. Final report 18 Sep 81-20 Sep 82  

Energy Technology Data Exchange (ETDEWEB)

The results of this study are in agreement with the precepts established in studies published previously on beef, chicken, ham, and pork. The radiolysis compounds from bacon, chicken, ham, and pork are comparable in identity and amounts to those found in irradiated beef for comparable compositions and irradiation parameters (temperature, dose, etc.). The results of this study support the conclusions drawn in the CORC report of 'commonality in chemistry, predictability of products, and extrapolation of results.' Consequently, the same conclusions can be drawn concerning the wholesomeness of irradiated bacon, chicken, ham, and pork as for other irradiated meat products of similar composition and irradiation parameters as reported in the FASEB report and its supplements (I and II) on irradiated beef.

1984-01-01

335

Effect of local irradiation on longitudinal bone growth in the rat. A tetracycline labelling investigation  

Energy Technology Data Exchange (ETDEWEB)

Young rats were given a single irradiation dose (0.5, 2, 5 or 8 Gy) to the left knee-joint. The right unexposed knee-joint served as control. The animals were decapitated 1.5, 3, 7, 14 or 30 days after the irradiation. Longitudinal bone growth in the tibial epiphysis was established using tetracycline as an intravital marker. During the first 1.5 days after irradiation with 5 and 8 Gy, the growth was slightly inhibited (6-7%). Maximum growth retardation (20%) was found 7 to 14 days after irradiation with 5 and 8 Gy. No consistent effect occurred after 0.5 and 2 Gy. Between 14 to 30 days following irradiation growth was normalized.

1983-01-01

336

Effect of #gamma#-irradiation on commercial polypropylene based mono and multi-layered retortable food packaging materials  

International Nuclear Information System (INIS)

Irradiation processing of food in the prepackaged form may affect chemical and physical properties of the plastic packaging materials. The effect of #gamma#-irradiation doses (2.5-10.0 kGy) on polypropylene (PP)-based retortable food packaging materials, were investigated using Fourier transform infrared (FTIR) spectroscopic analysis, which revealed the changes happening to these materials after irradiation. The mechanical properties decreased with irradiation while oxygen transmission rate (OTR) was not affected significantly. Colour measurement indicated that Nylon 6 containing multilayer films became yellowish after irradiation. Thermal characterization revealed the changes in percentage crystallinity.

2007-07-01

337

Development and Reproduction of grape phylloxera on irradiated in vitro cultured rootstocks  

International Nuclear Information System (INIS)

The ability of a local strain of grape phylloxera to develop and reproduce on irradiated in vitro cultured rootstocks (Ru140, R99 and 3309C and one local variety 'Helwani' was determined. The results showed that there was great variation in developmental time and reproduction of phylloxera between irradiated and unirradiated in vitro cultured plants. Survival, number of eggs and mean developmental time were greatly reduced when phylloxera was reared on irradiated rootstocks. Based on the examined biological parameters of phylloxera, all tested rootstocks would be more resistant toward such destructive insect when they were irradiated. Thus, phylloxera resistance was enhanced when in vitro cultured plants were treated with low doses of gamma irradiation. (author)

338

#gamma# irradiation of aqueous solutions of human hemoglobin in atmospheres of air and argon  

International Nuclear Information System (INIS)

In this study, the degrees of destruction of hemoglobin irradiated in atmospheres of air and argon were compared. Hemoglobin preparations were irradiated in the forms: oxyhemoglobin (HbO_2) deoxyhemoglobin (Hb"2"+) and methemoglobin (MetHb) applying doses of 0.5 to 5 Mrad. The degree of hemoglobin destruction was estimate on the basis of changes in the values of the absorption coefficient at the Soret band, the absorption ratio A_5_0_5/A_5_6_3 determined after conversion of irradiated preparations into MetHb, absorption coefficinets for pyridine hemochromogen obtained from irradiated preparations, and changes in parameters characterizing the hemoglobin oxygenation reaction (log p/sub 1/2/O_2 and the Hill n coefficient). The calculated oxygen enhancement ratios S were generally higher than 1 for the parameters estimated. This indicates that the presence of oxygen during ...

339

Isochron measurements of naturally irradiated K-feldspar grains  

International Nuclear Information System (INIS)

The equivalent doses of K-feldspar grains in a range of grain sizes from 90 to 250#mu#m diameter were measured using a single-aliquot regenerative-dose protocol for the infrared stimulated luminescence (IRSL) signals for two samples of desert sand. The equivalent doses for each sample were compared with that for the 125-150#mu#m grains of quartz from the same samples. The results suggested that the K-feldspar equivalent doses were underestimated because of anomalous fading. Measurements of the decay of the IRSL signals following laboratory irradiation for these two samples, and an additional one from a previously published isochron study, showed anomalous fading during the period of laboratory storage. The decay rate was about 3% per decade for all samples and was independent of the grain size used. Using plots of equivalent doses for K-feldspars as a function ...

2007-09-01

340

Creation and filling of thermoluminescence traps during irradiation  

Energy Technology Data Exchange (ETDEWEB)

A mathematical model has been constructed to describe the creation and filling of thermoluminescence traps during irradiation. Processes considered include trap filling, recombinations both between free charges and between free and trapped charges and thermal de-trapping. Also a simple trap creation term, linear with dose, has been included. A computer program has been written in order to solve the system of differential equations describing the various charge carrier flows during irradiation. The model and the program are described and the results of the application of the model to some simple energy-level schemes are discussed. Thermal de-trapping and band-to-band recombinations can introduce a dose rate dependence into the accumulation of trapped charge, whilst trap creation leads to the supralinear growth of charge trapped at certain defects with increasing dose.

1986-01-01

341

Surgical adjuvant therapy in colon carcinoma: a human tumor spheroid model for evaluating radiation sensitizing agents  

International Nuclear Information System (INIS)

HT-29 human colon tumor cells growing as spheroids have been evaluated as a model system for measuring the response of human colon tumor cell to antineoplastic agents. HT-29 cells have been capacity to form spheroids up to 1 mm or more in diameter when grown in spinner culture. The multicellular HT-29 spheroids develop hypoxic centers reflecting the cellular conditions found in human cancer treatment, i.e., nutritionally deficient hypoxic cells that are felt to be a significant source of both radiation and chemotherapy clinical treatment failures. Spheroids of increasing size were radiated and then dispersed into single cells for colony survival assay. Compared with irradiated single cell suspensions, the spheroid cells demonstrated a significant increase in radioresistance. Growing spheroids developed a complex radiation survival curve which was variable with respect to size of the spheroid. The drug 5-Fu was studied to examine in a preliminary fashion its ...

342

Destruction of Salmonellae on poultry meat with lysozyme, EDTA, x ray, microwave, and chlorine  

International Nuclear Information System (INIS)

Lysozyme, ethylenediaminetetracetic acid, chlorine, x-irradiation and microwaves were used in experimental attempts to eliminate Salmonella senftenberg 775W or Salmonella typhimurium from turkey drumsticks and whole carcasses. Turkey drumsticks or whole carcasses were artificially contaminated with S. senfenberg 775W or S. typhimurium in concentrations ranging between 5 x 10"5 to 8 x 10"5 viable cells per ml. of contaminating fluid. After each treatment, samples were cultured, plated, and tested according to standard methods to determine the susceptibility of Salmonella organisms to the particular treatment. A 0.1 percent solution of lysozyme eliminated the S. senftenberg 775W at 22"0C within three hours. A 0.5 percent solution of ethylenediaminetetracetic acid failed to destroy the test organism under the same conditions. Eighty thousand rads of X-ray eliminated the test organism on turkey drumsticks but failed to remove it from whole turkey ...

343

A simple template-free approach to TiO2 hollow spheres with enhanced photocatalytic activity.  

Science.gov (United States)

Mesporous anatase-phase TiO(2) hollow spheres with high photocatalytic activity were prepared by hydrothermal treatment and self-transformation of amorphous TiO(2) solid spheres in an NH(4)F aqueous solution. The prepared samples were characterized by X-ray diffraction, scanning and transmission electron microscopy, X-ray photoelectron spectroscopy, N(2) adsorption-desorption isotherms and UV-vis absorption spectroscopy. The photocatalytic activity was evaluated by photocatalytic oxidation decomposition of acetone in air under UV irradiation. It is found that F(-) plays an essential role in the formation of TiO(2) hollow spheres. F(-) not only induces the hollowing of TiO(2) solid spheres, but also promotes the crystallization of anatase TiO(2) nanocrystals. A possible formation mechanism for the TiO(2) hollow spheres by localized Ostwald ripening or chemically induced self-transformation is proposed based on the ...

2010-05-27

344

Algorithm for assessment of mean annual gonad dose and genetically significant dose from the data of personal dosimetry  

International Nuclear Information System (INIS)

During one year more than 40,000 items of information on radiation exposure of personnel involved in the handling of radiation sources and more than 5,000,000 items on irradiation of other people are collected in the authors' laboratory. Considerable progress in assessment of mean annual gonad dose of genetically sifnificant dose was attained by means of an algorithm for a personal computer. This simple and inexpensive system has led to a higher accuracy in the application of protective measures. (author).

1985-10-22

345

X-Ray Phase Imaging for Breast Cancer Detection  

Science.gov (United States)

... Accession Number : ADA535309. Title : X-Ray Phase Imaging for Breast Cancer Detection. Descriptive Note : Annual rept. 1 Sep 2009-31 Aug 2010 ...

2010-09-01

346

Subacute neuropathological effects of microplanar beams of x-rays from a synchrotron wiggler.  

UK PubMed Central (United Kingdom)

Microplanar beam radiation therapy has been proposed to treat brain tumors by using a series of rapid exposures to an array of parallel x-ray beams, each beam having uniform microscopic thickness and...Full Text Available

1995-09-12

347

Small-Angle X-ray Scattering of Reduced Ribonuclease A: Effects of Solution Conditions and Comparisons with a Computational Model of Unfolded Proteins  

UK PubMed Central (United Kingdom)

The disulfide-reduced form of bovine ribonuclease A (RNAse A), with the Cys thiols irreversibly blocked, was characterized by small-angle x-ray scattering (SAXS). To help resolve the conflicting...Full Text Available

2008-04-11

348

Radionuclide X-ray fluorescence analysis of waste water from the production of citric acid  

Energy Technology Data Exchange (ETDEWEB)

Radionuclide X-ray fluorescence analysis was used for the determination of iron, calcium, potassium, copper, manganese and zinc in waste water from the production process of citric acid.

1982-02-18

349

Radionuclide X-ray fluorescence analysis of waste water from the production of citric acid  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis was used for the determination of iron, calcium, potassium, copper, manganese and zinc in waste water from the production process of citric acid. (author).

1982-02-01

350

Radiation exposure due to X-rays of the hip joint in babies  

International Nuclear Information System (INIS)

Exact anatomic knowledge about the location of the gonads and the application of corresponding measures of radiation protection are the preconditions for an efficient reduction of the danger of a possible genetic damage as a result of radiation exposition during X-ray examination of the hip joint of newborns. (VJ).

351

PIXE analysis of GaAs and ZnSe  

Energy Technology Data Exchange (ETDEWEB)

The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K{sub {alpha}} X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K{sub {alpha}} X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be satisfied in order that the ...

1990-01-01

352

PIXE analysis of GaAs and ZnSe  

International Nuclear Information System (INIS)

The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K_#alpha# X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K_#alpha# X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be satisfied in order that the ...

1989-06-01

353

Numerical optimization of spherical variable-line-spacing grating X-ray spectrometers  

UK PubMed Central (United Kingdom)

Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and...Full Text Available

2011-03-01

354

Noise Characterization of Polycrystalline Silicon Thin Film Transistors for X-ray Imagers Based on Active Pixel Architectures  

UK PubMed Central (United Kingdom)

An examination of the noise of polycrystalline silicon thin film transistors, in the context of flat panel x-ray imager development, is reported. The study was conducted in the spirit of exploring...Full Text Available

2008-01-01

355

Measurements of accurate x-ray scattering data of protein solutions using small stationary sample cells  

UK PubMed Central (United Kingdom)

In this paper, we report a method of precise in situ x-ray scattering measurements on protein solutions using small stationary sample cells. Although reduction in the radiation damage...Full Text Available

2009-01-01

356

Magnetic fields of x-ray pulsars  

Energy Technology Data Exchange (ETDEWEB)

An analytic model of magnetic torques applied to an accreting neutron star is employed to evaluate the magnetic dipole moments of x-ray pulsars. A new type of close binary system containing a neutron star is suggested.

1982-09-01

357

Experimental X-ray intensity ratio L#beta#/L#alpha#  

International Nuclear Information System (INIS)

Experimental, relative intensities for the components of L X-ray were collected from literature, and atomic-number dependency of L#beta#/L#alpha# has been found. (author).

1980-01-01

358

Contribution to the radionuclide x-ray fluorescence analysis of human blood and plasma  

International Nuclear Information System (INIS)

A photon-induced x-ray fluorescence method allowing the simultaneous determination of iron, copper, zinc, bromine and rubidium in human blood and blood plasma samples is described. The method is reliable and has a good sensitivity for a wide range of elements. (author).

1986-04-01

359

Complex Spatio-Spectral Structure of Diffuse X-Ray emission in the ...  

Science.gov (United States)

SN 1987A: Soft X-Ray Intensity Ratio. 2002-12 to 2000-12. 2005-7 to 2002-12. Contours: 2002-12. (0.5 2 keV). (0.5 2 keV). Contours: 2005-7 ...

360

Chemical effects on K x-ray intensity ratios in chromium compounds  

International Nuclear Information System (INIS)

K_#beta#/ K_#alpha# x-ray intensity ratio of chromium were measured in different chromium compounds. The results show the variation of the intensity ratio as a function of the chemical environment around the metal ion. (author)

2003-02-10

361

Characterization and catalytic oxidation activity of uranium-bismuth mixed oxides  

International Nuclear Information System (INIS)

Bi-U mixed oxides were synthesized by two methods and characterized by X-ray diffraction and X-ray photoelectron spectroscopy. The samples were tested for the catalytic oxidation of carbon monoxide by oxygen. A stepwise redox mechanism consistent with the kinetic results is proposed. (orig.).

362

Chandra Observations of Nuclear X-ray Emission from a Sample of Radio Sources  

CERN Document Server

We present the X-ray properties of a sample of 17 radio sources observed with the Chandra X-ray Observatory as part of a project aimed at studying the X-ray emission from their radio jets. In this paper, we concentrate on the X-ray properties of the unresolved cores. The sample includes 16 quasars (11 core-dominated and 5 lobe-dominated) in the redshift range z=0.30--1.96, and one low-power radio-galaxy at z=0.064. No diffuse X-ray emission is present around the cores of the quasars, except for the nearby low-power galaxy that has diffuse emission on a scale and with a luminosity consistent with other FRIs. No high-amplitude, short-term variability is detected within the relatively short Chandra exposures. However, 1510-089 shows low-amplitude flux changes with a timescale of $\\sim$25 minutes. The X-ray spectra of the quasar cores are generally well described ...

2003-01-01

363

APOD: 2002 July 11 - M51: X Rays from the Whirlpool  

Science.gov (United States)

picture will download the highest resolution version available. M51: X-Rays from the Whirlpool Credit: A. Wilson (UMD) et al., CXC, NASA Explanation: Fresh from yesterday's...

2011-10-07

364

A comparison of iterative algorithms and a mixed approach for in-line x-ray phase retrieval  

UK PubMed Central (United Kingdom)

Previous studies have shown that iterative in-line x-ray phase retrieval algorithms may have higher precision than direct retrieval algorithms. This communication compares three iterative phase...Full Text Available

2009-08-15

365

8. Application of radionuclide X-ray fluorescence analysis in other fields of science and technology  

International Nuclear Information System (INIS)

Certain applications are described of radionuclide X-ray fluorescence analysis in the ore dressing industry, in the manufacture of building materials, in metallurgy, pharmacy, in the chemical, photographic and paper industries, in space exploration, in archeology and for measuring the thicknesses of thin layers of coatings. (ES).

1983-12-01

366

Preliminary Calculations of the Radiation Damage of the Permanent Magnets for TRADE (TRiga Accelerator Driven Experiment)  

CERN Document Server

Monte Carlo calculations of proton irradiation of permanent magnets for the TRADE experiment have been performed. An irradiation dose of about 4´106 Gy/yr/mA has been estimated due to beam losses in normal operating conditions. Existing experimental results indicate that this irradiation level may induce a considerable demagnetization: in fact, a dose of 6´107 Gy induces a remanence loss of 0.3 % on samples of Sm2Co17 magnets, which are the most resistant type. More detailed calculations with the final design of the magnets and of the beam line are suggested, to determine if the irradiation levels allowed a reliable operation of the permanent magnets for the entire duration of the TRADE experiment. Damage and gas production rates have also been calculated; the values obtained are very low, thus confirming that the demagnetization process is in great part ...

2002-01-01

367

Application of the microbiological method DEFT/APC to detect minimally processed vegetables treated with gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

Marketing of minimally processed vegetables (MPV) are gaining impetus due to its convenience, freshness and apparent health effect. However, minimal processing does not reduce pathogenic microorganisms to safe levels. Food irradiation is used to extend the shelf life and to inactivate food-borne pathogens. In combination with minimal processing it could improve safety and quality of MPV. A microbiological screening method based on the use of direct epifluorescent filter technique (DEFT) and aerobic plate count (APC) has been established for the detection of irradiated foodstuffs. The aim of this study was to evaluate the applicability of this technique in detecting MPV irradiation. Samples from retail markets were irradiated with 0.5 and 1.0 kGy using a {sup 60}Co facility. In general, with a dose increment, DEFT counts remained similar independent of the ...

2009-07-15

370

Superconducting properties of metallic superlattices  

Energy Technology Data Exchange (ETDEWEB)

The preparation by sputtering of artificial metallic superlattices is described, as are the results of x-ray structural determinations. Tunneling and resistivity measurements on these materials are reported.

1987-01-01

371

Radionuclide X-ray fluorescence analysis using semiconductor detectors  

International Nuclear Information System (INIS)

Czech May 1979. p. 32-33. Czechoslovakia Benada, J. Spacek, B. Ustav

1979-05-01

372
373

Plasma diagnostics in the optical and X-ray regions on the plasma focus device PF-4 (TULIP)  

International Nuclear Information System (INIS)

... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,

2006-09-11

374

Microcomputers in radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Czech Apr 1986. p. 51. Czechoslovakia Cechak, T. Kluson, J. Ceske

1986-04-01

375

Hard X-ray phase imaging and tomography using a grating interferometer  

International Nuclear Information System (INIS)

An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.

2007-07-01

376

Experimental study of X-ray vidicon  

International Nuclear Information System (INIS)

(1972). USSR Sviryakin, DI Manets, AI Kolupaev, AN v. 213 p. 111-114.

378

Electron-induced luminescence and x-ray spectrometer development: progress report  

Science.gov (United States)

The progress in the development of a surface analysis tool based on the excitation of characteristic

2003-01-01

379

Electron-Induced Luminescence and X-Ray Spectrometer (ELXS) System for Life Detection  

Science.gov (United States)

The ELXS concept is a novel, portable, micro-instrument targeted for the detection of mineralogic

2002-01-01

380

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

381

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

383

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds  

Energy Technology Data Exchange (ETDEWEB)

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds were studied by electron and proton bombardments. L{sub {gamma}1} X-rays which involve transition of 4d electrons of the valence shell were found to be sensitive to the chemical environment. The L{sub {gamma}1}/L{sub {beta}1} X-ray intensity ratio increased with an increase of the 4d electron occupation of niobium or molybdenum in niobium or molybdenum compounds, showing that the chemical effects can be ascribed to the 4d electron behavior of the metallic atom in its compounds. (orig.).

1990-12-20

384

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds  

International Nuclear Information System (INIS)

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds were studied by electron and proton bombardments. L_#gamma#_1 X-rays which involve transition of 4d electrons of the valence shell were found to be sensitive to the chemical environment. The L_#gamma#_1/L_#beta#_1 X-ray intensity ratio increased with an increase of the 4d electron occupation of niobium or molybdenum in niobium or molybdenum compounds, showing that the chemical effects can be ascribed to the 4d electron behavior of the metallic atom in its compounds. (orig.).

1990-12-01

385

Determination of volatiles produced during radiation processing in food and medicinal herbs; Determinacao de volateis produzidos durante o processamento por radiacao em ervas alimenticias e medicinais  

Energy Technology Data Exchange (ETDEWEB)

In order to protect food from pathogenic microorganisms as well as to increase its shelf life while keeping sensorial properties (e.g. odor and taste), once the latter are one of the main properties required by spice buyers, it is necessary to analyze volatile formation from irradiation of medicinal and food herbs. The aim of the present study was to analyze volatile formation from Co irradiation of Laurus Cinnamomum, Piper Nigrum, Origanum Vulgare and Myristica Fragans. Possible changes on the odor of these herbs are evaluated by characterizing different radiation doses and effects on sensorial properties in order to allow better application of irradiation technology. l he samples have been irradiated in plastic packages by making use of a {sup 60}Co Gamma irradiator. Irradiation doses of 0, 5, 10, 15, 20 and 25kGy have ...

2008-07-01

386

Growth and cell kinetic changes of HeLa S-3 spheroids following hyperfractionated irradiation  

International Nuclear Information System (INIS)

Optimal design of the hyperfractionated radiotherapy requires basic radiobiological data such as the critical dose per fraction, number of fractions per day and total equivalent dose, to name a few. As a prelude to in vivo hyperfractionated irradiation, the authors carried out experiments to determine quantitative changes in the proliferation and cell kinetic parameters of multicellular spheroids after hyperfractionated irradiation. Experiments were carried out with HeLa S-3 spheroid growing in MEM culture media. Hyperfractionated irradiation schedules were 1.5 Gy/f, 2f/day and 1.0 Gy/f, 3 f/day. At intervals after irradiation, cell numbers, growth delays and cell cycle distribution of spheroids were determined. The kinetic data were obtained by the use of flow cytometry. The most pronounced changes in cell kinetic parameters were early G/sub 2/M block, ...

387

The application of irradiation techniques for food preservation and processing improvement  

Energy Technology Data Exchange (ETDEWEB)

This project has intended to develop alternative techniques to be used in food industry for food processing and utilization by safe irradiation methods. For improvement of rheology and processing in corn starch by irradiation, the production of modified starch with low viscosity as well as with excellent viscosity stability became feasible by the control of gamma irradiation dose levels and the amount of added inorganic peroxides to starch. Also, this project was developed the improvement methods of hygienic quality and long-term storage of dried red pepper by gamma irradiation. And, in Korean medicinal plants, 10 kGy gamma irradiation was effective for improving sanitary quality and increasing extraction yield of major components. For the sanitization of health and convenience foods, gamma irradiation was more effective than ozone treatment ...

1997-09-01

388

Dose and temporary characteristics of the changes in the amount of nucleic acids in leucocytes of irradiated rats  

International Nuclear Information System (INIS)

An attempt was made for early quantitative assessment of the severety of an injury, using the nuclear acids (NA) content as a biochemical indicator. Sexually mature male rats with body mass 160-180 g were irradiated with doses 0.5, 1, 2, 4 and 8 Gy of "1"3"7Cs source. Uneven irradiation was achieved by shielding the abdominal-lumbar area with lead rings, measuring 2,5/50 mm. A 28-30% fall of the dose beneath the shielded zone was thus provided. Dose-dependent quantitative changes in Na content were determined on hours 24 and 72 within the range from 0.5 to 8 Gy and followed up until day 30 after irradiation with nonlethal (2 Gy) and lethal (8 Gy) doses. The total NA content in the leucocytes was determined by the method of Kritski and Aleksandrov. The uneven irradiation of rats within the 0,5-8 Gy range induced early ...

389

The optimum modification of energy spectra using FFT convolution/multigrid superposition algorithm on the focus radiation treatment system  

International Nuclear Information System (INIS)

In the convolution/superposition algorithm, the energy spectrum should be modified to make the reconstructed dose distribution consistent with the measured dose distribution. The energy spectrum, which gives the best agreement, is not determined uniquely depending on the reconstruction procedure. In this report, the effects of the characteristics of the energy spectrum on the calculation accuracy are evaluated by comparing the percentage depth dose (PDD) and beam profiles for the reference energy spectrum with those calculated for the modified spectrum in order to optimize the energy spectrum modification procedure when 4 and 10 MV X-ray beams are used. Decreasing the number of energy bins brought a larger decrease rate in the computation accuracy than a decrease rate in computation time. Further, the decrease of the number of energy bins led to a change of the energy spectrum. The balance of the ...

2003-06-01

390

Effects of low-level radiation upon the hematopoietic steam cell: implications for leukemogenesis  

Energy Technology Data Exchange (ETDEWEB)

These studies have addressed firstly the effect of single small doses of x-ray upon murine hematopoietic stem cells to obtain a better estimate of the D/sub q/. It is small, of the order of 20 rads. Secondly, a dose fractionation schedule tht does not kill or perturb the kinetics of hemopoietic cell proliferation was sought in order to investigate the leukemogenic potential of low level radiation upon an unperturbed hemopoietic system. The studies reported herein show tht 1.25 rads every other day decrease the CFU-S content of bone marrow by the time 40 rads are accumulated. Studies on the effect of 0.5, 1.0, 2.0, and 3.0 rads 3 times per week are under way. Two rads 3 times per week produced a modest decrease in CFU-S content of bone marrow after an accumulation of 68 rads. With 3.0 rads 3 times per week an accumulation of 102 rads produces a significant decrease in CFU-S content of bone marrow. Dose ...

1983-01-01

391

X-ray findings in patients with miliary appearance of metallic mercury after suicide attempt  

Energy Technology Data Exchange (ETDEWEB)

This case report evaluates X-ray findings in patients with miliary accumulation of mercury observed after parenteral application of metallic mercury in a suizide attempt. There are certain discrepancies between clinical symptoms and the X-ray findings. A clear demonstration of mercury in coronary blood vessels is possible by fluoroscopy.

1985-03-01

392

The evolution of x-ray binaries  

International Nuclear Information System (INIS)

These proceedings represent papers presented at the Astrophysics Conference in Maryland, USA. The topic of the Conference was the evolution of x-ray binaries and the papers encompass a wide range of subjects on x-ray astronomy. There were one hundred eighteen papers presented at the Conference and out of these three have been abstracted for the Energy Science and Technology database.

1993-10-11

393

Radionuclide X-ray fluorescence analysis of components of the environment  

International Nuclear Information System (INIS)

The physical foundations and methodology are described of radionuclide X-ray fluorescence analysis. The sources are listed of air, water and soil pollution, and the transfer of impurities into biological materials is described. A detailed description is presented of the sampling of air, soil and biological materials and their preparation for analysis. Greatest attention is devoted to radionuclide X-ray fluorescence analysis of the components of the environment. (ES).

1983-01-01

394

Quantitative phase imaging using hard x-rays  

International Nuclear Information System (INIS)

The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.

2009-02-01

395

Present state of radionuclide X-ray fluorescence analysis in coal mining  

International Nuclear Information System (INIS)

Applications of X-ray fluorescence analysis in coal mining and geology are briefly described based on results published in Czechoslovakia as well as abroad over the past 3 years. Particular attention is paid to the rapid determination of the ash content of coal using portable radionuclide X-ray fluorescence analyzers that are being developed in Czechoslovakia. (author).

1990-01-01

396

Pd-Na/F double exploding foil photoionization experiment  

Science.gov (United States)

The achievement of inner-shell photoionization of Zn-like Pd by means of two exploding foils is described. This resulted in the soft X-ray transition 3d94s2-3d104p at 46 A. It is shown that the photoionization of inner shell electrons in highly stripped ions can lead to X-ray transitions which may be candidates for X-ray lasers under 50 A.

1990-03-01

397

Nondestructive determination of airborne lead particulates by the radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).

1980-01-01

398

Multi-mirror system, 2. Application of inverse Compton Scattering for lithography X-ray sources  

Energy Technology Data Exchange (ETDEWEB)

A brilliant X ray source is proposed for lithography instruments with use of a multi-mirror system. The inverse Compton scattering between the stored electron beam in the storage ring and the stored photon beam in the multi-mirror system, is applied for the X-ray generation. (author)

2000-07-01

399

Measurement of the K?/K? ratio for muon alpha sticking X-rays in muon catalyzed d-t fusion at the RIKEN-RAL Muon Facility  

International Nuclear Information System (INIS)

At the RIKEN-RAL Muon Facility, ?- to ? sticking K? X-rays were observed for the first time taking advantage of the pulsed beam structure. The precision of the present measurements was insufficient to distinguish between theoretical models, however the observed K?/K? X-ray intensity ratio tends to be smaller than most of these theoretical predictions.

1999-06-01

400

Genetic and somatic risks in X-ray diagnosis  

International Nuclear Information System (INIS)

Based on a literature study an actual summary of the risk-utility problems in X-ray diagnosis is outlined due to the Recommendations of the International Commission for Radiation Protection (ICRP publication 26/1977). Papers demonstrating quantitative assessment of the somatic and genetical risk in X-ray examination are preferably cited and evaluated. It is concluded that the somatic and genetical risk is low in diagnostic ratiology. However, it must not be neglected and has always to be compared to the utility of an examination as well as to other risks of the examination. (author).

1982-01-01

401

From tomography to voludensitometry: radiation detectors for industrial control and medical instrumentation; De la tomographie a la voludensitometrie: les capteurs pour le controle industriel et l`instrumentation medicale  

Energy Technology Data Exchange (ETDEWEB)

In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).

1993-12-01

402

Determination of ash in coal by X-ray backscattering and X-ray fluorescence analysis and apparatus by the PAR company  

International Nuclear Information System (INIS)

The basic principles of determination of the ash content of coal by the title methods are outlined. A brief technical characteristic of the ash meters and radionuclide X-ray fluorescence analyzers manufactured by the PAR company is presented. (Z.S.). 4 figs., 7 refs.

1993-01-01

403

Contribution to the in vitro multielement X-ray fluorescence analysis of human soft tissues  

International Nuclear Information System (INIS)

Determination of Mn, Fe, Ni, Cu, Zn, and Pb in human soft tissues by radionuclide X-ray fluorescence analysis (using "2"3"8Pu and "1"0"9Cd sources) is described. The results of multielement XRS analysis of selected human tissues are tabulated. They are in good agreement with the literature data. It is concluded that X-ray fluorescence technique is a suitable method for trace element determination. (author).

1986-11-01

404

Fractionation of combined heat and radiation in asynchronous CHO cells. II. The role of cell-cycle redistribution  

Science.gov (United States)

Asynchronous Chinese hamster ovary (CHO) cells treated with conditioning hyperthermia (10 min at 45/sup 0/C) followed immediately by x irradiation with 4 Gy at room temperature display a decreased radiation response when either irradiated, or heated and irradiated again 24 h later. In addition, conditioning by 4 Gy of x radiation alone followed at 24 h by the combined heat and radiation treatment als resulted in a larger radiation D/sub 0/. Since the differential cell-cycle responses to heat- and x-ray-induced lethality are well established for CHO cells, the potential role of cell-cycle redistribution in the observed radiation desensitization was investigated by flow cytometry. At 24 h after the combined treatment, the fraction of the cells found in the G/sub 2/ + M portion of the DNA histograms was about three times that of the controls and there was a concomitant reduction in both the G/sub 1/ and S ...

1979-11-01

405

Phytochrome-induced Increase of Fluorescein Translocation in Mung Bean Hypocotyls  

UK PubMed Central (United Kingdom)

Moderate doses of red (660 nanometer) irradiation cause a rapid increase in the translocation of fluorescein in dark-grown mung bean hypocotyl (Vigna radiata L.) segments. The increase...Full Text Available

1978-07-01

406

Induction of apoptosis in chicken bursal B cells  

Energy Technology Data Exchange (ETDEWEB)

Cell death in general can be a physiological process of cell number regulation in tissue, or it can be the result of exo or endogenous injuries, such a low-dose of radiation. Chicken B cell population in the bursa of Fabricius are very susceptible to PCD. Our present studies concern the development of radiation damage of chicken defence mechanisms. In 6 experiments pathogen free chicken were irradiated by gamma rays with the total doses of 0.25, 0.5, 1.0, 2.0 and 4.0 Gy. The induction of apoptosis was checked by Flow-cyto-meter 12 h after irradiation in bursa cell suspension. There is some increase in the number of induced apoptotic cells 12 h after irradiation at the dose 0.5-.4.0 Gy. There were no significant changes in the proportion of proliferating lymphocytes (G2 M), but cellularity decreased significantly at dose 2.0 and 4.0 Gy/12 h ...

1997-03-01

408

Influence of high energy electron irradiation on the characteristics of polysilicon thin film transistors  

Energy Technology Data Exchange (ETDEWEB)

The influence of high energy electron (23 MeV) irradiation on the electrical characteristics of p-channel polysilicon thin film transistors (PSTFTs) was studied. The channel 220 nm thick LPCVD (low pressure chemical vapor deposition) deposited polysilicon layer was phosphorus doped by ion implantation. A 45 nm thick, thermally grown, SiO{sub 2} layer served as gate dielectric. A self-alignment technology for boron doping of the source and drain regions was used. 200 nm thick polysilicon film was deposited as a gate electrode. The obtained p-channel PSTFTs were irradiated with different high energy electron doses. Leakage currents through the gate oxide and transfer characteristics of the transistors were measured. A software model describing the field enhancement and the non-uniform current distribution at textured polysilicon/oxide interface was developed. In order to assess the irradiation-stimulated ...

2006-08-15

409

Influence of high energy electron irradiation on the characteristics of polysilicon thin film transistors  

International Nuclear Information System (INIS)

The influence of high energy electron (23 MeV) irradiation on the electrical characteristics of p-channel polysilicon thin film transistors (PSTFTs) was studied. The channel 220 nm thick LPCVD (low pressure chemical vapor deposition) deposited polysilicon layer was phosphorus doped by ion implantation. A 45 nm thick, thermally grown, SiO_2 layer served as gate dielectric. A self-alignment technology for boron doping of the source and drain regions was used. 200 nm thick polysilicon film was deposited as a gate electrode. The obtained p-channel PSTFTs were irradiated with different high energy electron doses. Leakage currents through the gate oxide and transfer characteristics of the transistors were measured. A software model describing the field enhancement and the non-uniform current distribution at textured polysilicon/oxide interface was developed. In order to assess the irradiation-stimulated ...

2006-08-01

410

Study of metal concentration in sediment of some springs of Lebanon  

International Nuclear Information System (INIS)

Full text.Surficial sediment samples were collected from seventeen springs distributed all over Lebanon (east, west, north and south). Concentrations of metals Ca, Fe, Mn, Ni, Cu, Cr, Zn and Pb were determined by energy dispersive x-ray fluorescence technique. Irradiation was done by the radioisotope source Cd-109 and the detection by an EG and G Si(Li) detector. These analysis was done in attempt to assess the impact of anthropogenic sources on ground water quality. Metals concentration in sediment were found to be (Ca:0.05-47%, Fe:0.24-4.2%, Cr:

1999-11-02

411

Real-time neutron radiography at the Iea-R1 m nuclear research reactor  

International Nuclear Information System (INIS)

A LIXI (Light Intensifier X-ray Image) device has been employed in a real-time neutron radiography system. The LIXI is coupled to a video camera and the real-time images can be observed in a TV monitor, and processed in a computer. In order to get the real-time system operational, the neutron radiography facility installed at the IEA-R1 m nuclear research reactor of the IPEN-CNEN/S P has been optimized. The most important improvements were the neutron/gamma ratio, the effective energy of the neutron beam, decrease of the scattered radiation at the irradiation position, and the additional shielding of the video camera. Several one-frame as well as computer processed images are presented. The overall Modulation Transfer Function for the real-time system was obtained from the resolution parameter p = 0:44 +- 0:04 mm; the system sensitivity, evaluated for a Perspex step wedge, was determined and the average value is 0:70 +- 0:09 mm. (author)

2003-06-01

412

Precise characterisation of nanochannels in track etched membranes by SAXS and SANS  

Energy Technology Data Exchange (ETDEWEB)

Poster session: Abstract is full text. Track membranes are thin polymer foils irradiated by heavy ions. The defects created by the heavy ions are located along the ions trajectory, the track. It is possible to open channels by etching with a chemical agent. These channels are very uniform. Small Angle Scattering (of X rays and neutrons) give global information about the characteristics of the channel shape. As the nanochannels are strictly parallel, an excellent sample orientation is required to obtain interpretable spectra. Then shoulders due to the oscillations of the Bessel function (radial part of the channel shape Fourier transform) are easily seen in the scattered intensity in the PXY data treatment software of SAS spectra allow to determine the channel diameter with its dispersion law, to demonstrate the existence of a wall thickness with a linearly varying density, and to assess the roughness. PXY can also detect ...

2003-05-01

413

Laser induced local and periodic phase transformations in iron oxide thin films obtained by chemical vapour deposition  

International Nuclear Information System (INIS)

Iron oxide films have been deposited on Si(100) substrates by chemical vapour deposition (CVD) of iron(III) tert-butoxide ([Fe(O "tBu)_3]_2) in the temperature range 350-450 deg. C. The precursor flux and substrate temperature were varied to control the phase composition, average grain size and film thickness. The nature of substrate and deposition temperature markedly influence the morphology and iron-oxygen stoichiometry in the CVD deposits. Phase transformations in iron oxide films were achieved through precise local and periodic heating of the films by interfering laser beams. The interaction of iron oxide films with short laser pulses (Nd:YAG, 355 nm) induced partial transformation of hematite (#alpha#-Fe_2O_3) to magnetite (Fe_3O_4) or magnetite to wuestite (Fe_1_-_xO), respectively. The phase characterization and morphology of the hematite and magnetite films were investigated before and after laser irradiation by X-ray diffractometry, ...

2005-07-15

414

Free-electron laser beam  

International Nuclear Information System (INIS)

The principle and history of free-electron laser (FEL), first evidenced in 1977, the relationship between FEL wavelength and output power, the high-power FEL driven by the superconducting linac, the X-ray FEL by the linac, and the medical use are described. FEL is the vacuum oscillator tube and essentially composed from the high-energy linac, undulator and light-resonator. It utilizes free electrons in the vacuum to generate the beam with wavelength ranging from microwave to gamma ray. The first high-power FEL developed in Japanese Atomic Energy Research Institute (JAERI) is based on the development of superconducting linac for oscillating the highest power beam. In the medical field, applications to excise brain tumors (in US) and to reconstruct experimentally blood vessels in the pig heart (in Gunma University) by lasing and laser coagulator are in progress with examinations to remove intra-vascular cholesterol mass by irradiation of 5.7#mu#m ...

2003-06-01

415

Composition Dependence of the Photocatalytic Activities of BiOCl1-xBrx Solid Solutions under Visible Light  

British Library Electronic Table of Contents (United Kingdom)

Abstract We prepared BiOCl1-xBrx (x=0-1) solid solutions and characterized their structures, morphologies, and photocatalytic properties by X-ray diffraction, diffuse reflectance spectroscopy, scanning electron microscopy, Raman spectroscopy, photocurrent and photocatalytic activity measurements and also by density functional theory calculations for BiOCl, BiOBr, BiOCl0.5Br0.5. Under visible-light irradiation BiOCl1-xBrx exhibits a stronger photocatalytic activity than do BiOCl and BiOBr, with the activity reaching the maximum at x=0.5 and decreasing gradually as x is increased toward 1 or decreased toward 0. This trend is closely mimicked by the photogenerated current of BiOCl1-xBrx, indicating that the enhanced photocatalytic activity of BiOCl1-xBrx with respect to those of BiOCl and BiO...

2011-01-01

416

CR portal imaging; A linac graphy using storage phosphor imaging systems  

Energy Technology Data Exchange (ETDEWEB)

In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In computed radiography, image processing (tone scale modification and edge enhancement) is possible, and is advantageous portal ...

1992-07-01

417

CR portal imaging  

International Nuclear Information System (INIS)

In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In computed radiography, image processing (tone scale modification and edge enhancement) is possible, and is advantageous portal ...

1992-01-01

418

Radiation hardening characterization of a VDMOS developed at CAS institute of microelectronics  

International Nuclear Information System (INIS)

Total dose irradiation effects on a VDMOS developed at Institute of Microelectronics, CAS were investigated, particularly the electric parameter changes under different bias conditions. It was found that the breakdown voltage degradation by the irradiation depended mainly on the drain bias, whereas the threshold voltage degradation depended mainly on the gate bias. Thus, an innovative and effective method to domestic VDMOS total dose ionization characterization is that threshold voltage radiation hardening characterization should be tested on gate bias condition, and the breakdown voltage radiation hardening characterization, be tested on the drain bias. (authors)

2008-08-01

419

Comparisons of Monte Carlo calculations with absorbed dose determinations in flat materials using high-current, energetic electron beams  

International Nuclear Information System (INIS)

International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the ...

2007-08-01

420

Synergistic effect of helium and hydrogen for defect evolution under multi-ion irradiation of Fe-Cr ferritic alloys  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to evaluate the synergistic effect of helium and hydrogen on Fe-Cr ferritic model alloys, to provide basic understanding concerning development of fusion reactor components. Single, dual and triple ion-beams consisting of Fe{sup 3+}, He{sup +} and H{sup +} were used for irradiation, at temperatures 470-600 deg. C and dose to 50 dpa at 1 {mu}m. The dual beam irradiation with He enhanced cavity nucleation extensively to swelling of about 0.4%, whereas the dual beam irradiation with H did not significantly affect the microstructure. In the case of triple ion irradiation, the synergistic effect of He and H was confirmed clearly; relative large void formation and enhanced swelling to almost 5%. The synergistic effect suggests that the role of H is important for void growth and dislocation bias.

2004-08-01

421

Evaluation of induced radioactivity in 10 MeV-electron irradiated spices, (1)  

International Nuclear Information System (INIS)

Black pepper, white pepper, red pepper, ginger and turmeric were irradiated with 10 MeV electrons from a linear accelerator to a dose of 100 kGy and radioactivity was measured in order to estimate induced radioactivity in the irradiated foods. Induced radioactivity could not be detected significantly by #gamma#-ray spectrometry in the irradiated samples except for spiked samples which contain some photonuclear target nuclides in the list of photonuclear reactions which could produce radioactivity below 10 MeV. From the amount of observed radioactivities of short-lived photonuclear products in the spiked samples and calculation of H_5_0 according to ICRP Publication 30, it was concluded that the induced radioactivity and its biological effects in the 10 MeV electron-irradiated natural samples were negligible in comparison with natural radioactivity from "4"0K contained in the ...

422

Optimization of X-ray energy resolution from a horizontally focused single-crystal monochromator  

Energy Technology Data Exchange (ETDEWEB)

A method has been developed to optimize the energy resolution of a horizontally focusing monochromator. The method consists of determining the optimum radius of curvature of the cylindrically bent monochromator crystal by minimizing the total diffracted X-ray flux measured through an X-ray absorption foil. When measured at an absorption edge a global minimum can be identified, which corresponds to the minimum energy band accepted along the entire length of the crystal. Experimental verification of this method has been validated by comparing X-ray fluorescent scans taken for a series of crystal curvatures and by directly measuring the X-ray beam profiles at the corresponding points. The actual optical configuration and asymmetric-cut parameter of the focusing monochromator on beamline X4C at the National Synchrotron Light Source are modeled and ray tracing simulations of the optical system are compared ...

2009-02-11

423

Miniature x-ray source  

Energy Technology Data Exchange (ETDEWEB)

A miniature x-ray source utilizing a hot filament cathode. The source has a millimeter scale size and is capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature source consists of a compact vacuum tube assembly containing the hot filament cathode, an anode, a high voltage feedthru for delivering high voltage to the cathode, a getter for maintaining high vacuum, a connector for initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is fabricated from highly x-ray transparent materials, such as sapphire, diamond, or boron nitride.

2000-01-01

424

Gauging film thickness: A comparison of an x-ray diffraction technique with Rutherford backscattering spectrometry  

Energy Technology Data Exchange (ETDEWEB)

An x-ray diffraction technique for determining thin-film thickness is presented which should prove to be a valuable alternative to the array of spectroscopies (Rutherford backscattering spectrometry, Auger electron spectroscopy, etc.) currently favored for these measurements. Some of the virtues of this x-ray diffraction approach are its nondestructive nature, fast data acquisition rate (enabling in situ observations), thickness resolution better than 5 nm, and conventional equipment requirements. Results are shown for Pd/sub 2/Si thin films grown during isothermal annealing of Pd coatings (100 nm) on Si at 200 /sup 0/C for various amounts of time. A comparison of these x-ray measurements with Rutherford backscattering spectrometry data taken from the same specimens is used to demonstrate the validity of the x-ray technique.

1985-01-15

425

Fully Coherent X-ray Pulses from a Regenerative Amplifier Free Electron Laser  

Energy Technology Data Exchange (ETDEWEB)

We propose and analyze a novel regenerative amplifier free electron laser (FEL) to produce fully coherent x-ray pulses. The method makes use of narrow-bandwidth Bragg crystals to form an x-ray feedback loop around a relatively short undulator. Self-amplified spontaneous emission (SASE) from the leading electron bunch in a bunch train is spectrally filtered by the Bragg reflectors and is brought back to the beginning of the undulator to interact repeatedly with subsequent bunches in the bunch train. The FEL interaction with these short bunches not only amplifies the radiation intensity but also broadens its spectrum, allowing for effective transmission of the x-rays outside the crystal bandwidth. The spectral brightness of these x-ray pulses is about two to three orders of magnitude higher than that from a single-pass SASE FEL.

2006-02-17

426

Luminescence of Strontianite (SrCO{sub 3}) from Strontian (Scotland, UK)  

Energy Technology Data Exchange (ETDEWEB)

An historic Strontianite-type specimen from Strontian, Scotland, UK, was characterized to broaden our knowledge on luminescence properties of common carbonates. These fibrous aggregates are Strontianite (Sr{sub x}Ca{sub 1-x}CO{sub 3}) with circa 6% of CaO, interfacial water, hydrosilicate anions and substitutional divalent cations, e.g., Ca{sup 2+}, Mn{sup 2+}, Fe{sup 2+} in structural Sr{sup 2+} positions. The specimen was analyzed by X-ray Fluorescence Spectrometry (XRF), Environmental Scanning Electron Microscopy coupled with an Energy Dispersive X-ray Spectroscopy (ESEM-EDS) probe, Spatially-resolved Cathodoluminescence under the Scanning Electron Microscope (SEM-CL), Differential-Thermal Analyses (DTA), Thermogravimetry (TG), Thermoluminescence (TL), Radioluminescence (RL) and High Resolution Spectra Thermoluminescence (3DTL), to gain an overview of the spectral emissions, the defect linkages were modified by heating from room temperature ...

2009-04-15

427

Elective ilioingunial lymph node irradiation  

International Nuclear Information System (INIS)

Most radiologists accept that modest doses of irradiation (4500-5000 rad/4 1/2-5 weeks) can control subclinical regional lymph node metastases from squamous cell carcinomas of the head and neck and adenocarcinomas of the breast. There have been few reports concerning elective irradiation of the ilioinguinal region. Between October 1964 and March 1980, 91 patients whose primary cancers placed the ilioinguinal lymph nodes at risk received elective irradiation at the University of Florida. Included are patients with cancers of the vulva, penis, urethra, anus and lower anal canal, and cervix or vaginal cancers that involved the distal one-third of the vagina. In 81 patients, both inguinal areas were clinically negative; in 10 patients, one inguinal area was positive and the other negative by clinical examination. The single significant complication was a bilateral femoral neck fracture. The inguinal areas ...

428

EPR investigation of some traditional oriental irradiated spices  

International Nuclear Information System (INIS)

The 9.50 GHz electron paramagnetic resonance (EPR) spectra of unirradiated and "6"0Co #gamma#-ray irradiated cardamom (Elettaria cardamomum L. Maton, Zingiberaceae), ginger ((Zingiber officinale Rosc., Zingiberaceae), and saffron (Crocus sativus L., Iridaceae) have been investigated at room temperature. All unirradiated spices presented a weak resonance line with g-factors around free-electron ones. After #gamma#-ray irradiation at an absorbed dose of up to 11.3 kGy, the presence of EPR spectra whose amplitude increase monotonously with the absorbed dose has been noticed with all spices. A 100 "oC isothermal annealing of 11.3 kGy irradiated samples has shown a differential reduction of amplitude of various components that compose initial spectra, but even after 3.6 h of thermal treatment, the remaining amplitude represents no less then 30% of the initial ones. The same peculiarities ...

2007-06-01

429

Quality Management for Neutron Transmutation Doping of Silicon Ingot in HANARO  

Energy Technology Data Exchange (ETDEWEB)

By using this doping method, silicon semiconductors with extremely uniform dopant distributions can be produced, and this is the dominant advantage of NTD compared with a conventional chemical doping. Good uniformity of a dopant concentration is usually required for high power applications such as thyristor (SCR), IGBT, IGCT and GTO and for special sensors. Achieving an accurate neutron fluence corresponding to a target resistivity as well as a uniform irradiation is the prime target of a neutron irradiation for NTD. Generally, in order to reach an accurate neutron fluence, a real time neutron flux is monitored by a neutron detector such as a Self-powered Neutron Detector(SPND). And, after an irradiation, the total irradiation fluence is confirmed by measuring the absolute activity of a neutron activation sample that has been irradiated with a silicon ingot, and thus the SPND can be ...

2007-10-15

430

Antioxidant properties of natural substances in irradiated fresh poultry  

Energy Technology Data Exchange (ETDEWEB)

This study was undertaken to determine if a combined treatment (marinating in natural plant extracts or vacuum) with irradiation could have a synergistic effect, in order to prevent the lipid oxidation resulting in the development of undesirable flavours. The fresh chicken legs were irradiated at 0,3 and 5 kGy. The fatty acids composition of lipids was identified using gas liquid chromatography. The effect of irradiation treatment combined with a pre-treatment on the fatty acids composition was followed. The day after irradiation, ten panallists were asked to evaluate, using the instruction scaling, the overall appearance, the odor, the flavor and the overall acceptability of the samples. The major fatty acids identified in lipids were oleic acid, palmitic acid, palmitoleic acid and stearic acid. Pre-treatments have a significant effect on linoleic acid (C18:2) and higher fatty acids. The unsaturated ...

1998-06-01

431

Scatter measurements for optical cone-beam computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Both x-ray and optical cone-beam CT (CBCT) scanners are limited by scattered photons that contaminate the primary images. Transparent radiochromic gels and plastics are anticipated to produce less scattering than polymerization gels and hence result in reconstructed dose distributions with greater contrast and dynamic range. Four methods of scatter measurement were investigated to quantify scatter fractions using an in-house optical CBCT scanner. The methods consisted of generating either 'coin' shadows or primary beamlets in transmission images. The four methods generated similar results of 10% scatter fractions in gel transmission images for this particular scanner configuration with both leuco crystal violet and carbon black micelle gels. The scatter contributions were distributed as 5% from micelle gel, 2% from Teflon wall, 2% from refractive index matching liquid and 1% other sources. Applying a uniform background ...

2009-05-01

432

Radiation damage and hardening of molybdenum in 29 MeV alpha particle straggling zone  

International Nuclear Information System (INIS)

Technique, allowing to investigate straggling zone (full braking) from high-energy charged particles in detail, is described. Experimental results on investigation of efective structure, created in polycrystalline molybdenum (99.97%) within 29 MeV alpha-particles straggling zone for fluences from 3.8x10"1"9 up to 3.7x10"2"1 #alpha#/m"2 by methods of microhardness (H_#mu#, X-ray structural analysis (#DELTA#a/a) and transparent electron microscopy (TEM), are presented. It is determined, that for doses from 3.8x10"2"0 #alpha#/m"2 and higher, at #approx#6 MeV energy, molybdenum ''softening'' is observed, H_#mu# curve within straggling zone is well described by alloyage calculated profile. #DELTA#a/a measurements within straggling zone are well described by damage profile. TEM-investigations have shown the developed defective structure even within molybdenum ''softening'' range.

433

Hydrogen behavior in the iron surface layer modified by plasma nitriding and ion boronising  

Energy Technology Data Exchange (ETDEWEB)

The effects of the plasma nitriding with the formation of compound nitride and diffusion zones and of the boronising with the different ion doses on hydrogen distribution and hydrogen induced deterioration of a surface layer were examined in the case of Armco iron. Electrochemical studies of hydrogen permeation rate, hydrogen vacuum extraction measurements, optical and scanning microscopy, X-ray diffraction and elastic recoil detection analysis (ERDA) were used. Accumulation of entering hydrogen within the various constituent zones of the modified layer inhibits the hydrogen transport into the metal and thus, decreases the mean hydrogen content in the deeper zones and in the core. Hydrogen accumulation within the compact nitride zone causes the expansion of the nitride lattice, nitride phase transformation and deterioration. The ion boronising enhances the hydrogen effects in the plasma nitrided layers. Therefore, modification of the surface ...

2000-12-01

434

TRANSMUTATIONS IN SiC IRRADIATED IN ARIES-IV FIRST WALL  

Science.gov (United States)

The change in concentrations of elements due to transmutations resulting from neutron irradiation in the first wall of the ARIES-IV conceptual fusion energy device were determined as a function of neutron dose. SiC burns out at a rate of about 0.5% per effective full power year. The largest impurity concentration is that of He, but several other elements burn in at rates of hundreds of appm/efpy.

2001-04-01

435

Radiation-annealing hardening of vanadium  

International Nuclear Information System (INIS)

Mechanical properties of vanadium, irradiated with fast neutrons up to 8.6x10"-"4 dpa depending on postirradiation annealing temperature, are studied. It is shown that radiation-annealing hardening (RAH) is observed at 300 deg C, which agrees with earlier performed studies. It is first stated that RAH is accompanied by plasticity decrease. Phenomenological model permitting to explain RAH dependence on irradiation temperature and dose and also on content of chemically active alloying impurities is suggested.

436

Effect of some physical treatments on anti nutritional factors and fatty acids composition of Vicia faba L. seeds  

International Nuclear Information System (INIS)

This study was carried out to evaluate the effects of irradiation (gamma irradiation at dose levels of 0.0, 2.5, 5.0, 10.0 or 20.0 kGy, He-Ne and their combination) on nutritive characteristics of Vicia faba L. seeds (Giza 843). Analyses included levels of anti-nutrients (total phenolic compounds, tannins, phytic acid, trypsin inhibitor and vicine), chemical composition (sugars, crude proteins, fat, dry matter and ash) and fatty acids profile. All treatments caused significant (P<0.05) decreases in the antinutrational factors under investigation. The reduction in the content of tannins and phenolic compounds were more pronounced with He-Ne alone or He-Ne in combination with gamma irradiation. At dose levels 10.0 and 20.0 kGy without or with combination of He-Ne were more efficiency in the reduction of phytic acid content by 24.3, 32.8, 34.5 and 45.5 %, respectively. Also, for ...

437

Measurement of the L sub 2 - L sub 3 Coster-Kronig transition probability in Tm( Z =69)  

Energy Technology Data Exchange (ETDEWEB)

The {ital L}{sub 2}-{ital L}{sub 3} Coster-Kronig transition probability ({ital f}{sub 23}) in Tm was measured by multiparameter {ital K} versus {ital L} x-ray coincidence techniques. The Tm x rays were obtained from a radioactive source of {sup 169}Yb and were detected with cooled germanium and silicon detectors of high-energy resolution. Corrections were applied for the contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak and for the contribution of unresolved {ital L}{eta} x rays to the {ital L}{alpha}{sub 1,2} x-ray peak. The contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak was determined solely from the results of the coincidence measurements using a method of ...

1989-11-01

438

Measurement of the L sub 2 - L sub 3 Coster-Kronig transition probability in Tm( Z =69)  

Science.gov (United States)

The {ital L}{sub 2}-{ital L}{sub 3} Coster-Kronig transition probability ({ital f}{sub 23}) in Tm was measured by multiparameter {ital K} versus {ital L} x-ray coincidence techniques. The Tm x rays were obtained from a radioactive source of {sup 169}Yb and were detected with cooled germanium and silicon detectors of high-energy resolution. Corrections were applied for the contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak and for the contribution of unresolved {ital L}{eta} x rays to the {ital L}{alpha}{sub 1,2} x-ray peak. The contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak was determined solely from the results of the coincidence measurements using a method of ...

1989-11-01

439

Dosimetry limitations and a dose correction methodology for step-and-shoot IMRT  

Energy Technology Data Exchange (ETDEWEB)

For the step-and-shoot intensity-modulated radiation therapy (IMRT) technique, the combination of high dose rate, multiple beam segments and low dose per segment can lead to significant differences between the planned dose and the dose delivered to the patient. In this technique, a dose delivery inaccuracy known as the 'overshoot' effect is caused by the dose servo control system. This typically occurs in the first and last beam segments and causes an over- and underdose, respectively. Some dose positional error in the segment sequence is also possible there. Commercial ionization chambers (RK-type) and radiographic Kodak films were used for the measurements. The reported results were obtained using the Pinnacle{sup 3}-V6.2 treatment planning system and a Varian Clinac 21 EX linear accelerator equipped with a 120-leaf ...

2006-02-07

440

Using a photon phase-space source for convolution/superposition dose calculations in radiation therapy  

International Nuclear Information System (INIS)

For a given linac design, the dosimetric characteristics of a photon beam are determined uniquely by the energy and radial distributions of the electron beam striking the x-ray target. However, in the usual commissioning of a beam from measured data, a large number of variables can be independently tuned, making it difficult to derive a unique and self-consistent beam model. For example, the measured dosimetric penumbra in water may be attributed in various proportions to the lateral secondary electron range, the focal spot size and the transmission through the tips of a non-divergent collimator; the head-scatter component in the tails of the transverse profiles may not be easy to resolve from phantom scatter and head leakage; and the head-scatter tails corresponding to a certain extra-focal source model may not agree self-consistently with in-air output factors measured on the central axis. To reduce the number of adjustable variables in beam modelling, we replace ...

2005-09-07

441

Comparison of bone cancer risks in beagle dogs for inhaled plutonium-238 dioxide, inhaled strontium-90 chloride, and injected strontium-90  

Energy Technology Data Exchange (ETDEWEB)

There is a continuing need to understand dose-response relationships for ionizing radiation in order to protect the health of the public and nuclear workers from undue exposures. However, relatively few human populations have been exposed to doses of radiation high enough to cause observable, long-term health effects from which to derive dose-response relationships. This is particularly true for internally deposited radionuclides, although much effort has been devoted to epidemiological studies of the few types of exposures available, including lung cancers in uranium miners form the inhalation of the radioactive decay products of Ra, liver cancers in patients injected with Thorotrast X-ray contrast medium containing Th, bone cancers in radium dial painters who ingested Ra, and bone cancers in patients who received therapeutic doses of Ra. These four types of exposures to internally ...

1995-12-01

442

X-ray production with sub-picosecond laser pulses  

Energy Technology Data Exchange (ETDEWEB)

The interaction of intense, sub-picosecond laser pulses with solid targets produces intense picosecond x-ray pulses. With focused laser pulses of several 10 {sup 18} W/cm{sup 2}, He-like and H-like line radiation from targets such as aluminum and silicon has been produced. The energy conversion efficiency from the laser pulse energy to the 1--2 keV line x-rays is nearly one percent. The duration of the line x-ray radiation is of the order of ten picoseconds, although this may be an upper estimate because of the temporal resolution of the x-ray streak camera. The spatial extent of the x-ray source region is only slightly larger than the laser focal spot, or about 10 {mu}m in diameter. With these characteristics, such x-ray sources emit an intensity of nearly 10{sup 14} W/cm{sup 2}. Experiments and modeling which led to the above conclusions will be discussed.

1993-12-31

443

Portable fluid X-ray diagnostic system  

Energy Technology Data Exchange (ETDEWEB)

A portable X-ray image system is described comprising: (a) a base assembly including panels and hinges joining the panels together along edges, and compression stops for biasing the hinges to compensate for the weight of payload when mounted on the base assembly, the compression stops being located for interaction with the hinges for biasing the panels to exhibit upward bowing when laid upon a flat surface prior to loading, and to provide resiliency for facilitating the base assembly assuming a substantially flat configuration when a predetermined payload is placed upon the base assembly; (b) an X-ray member; (c) apparatus for detachably mounting a table member to the base assembly to hold the table member at a location above the base; (d) an X-ray source; (e) means for sensing X-rays to form an image; (f) means for mounting the X-ray source and the X-ray ...

1989-02-14

444

Hard X-ray identification of Eta Carinae and steadiness close to periastron  

CERN Document Server

Context: The colliding-wind binary Eta Car exhibits soft X-ray thermal emission that varies strongly around periastron, and non-thermal emission seen in hard X-rays and gamma-rays. Aims: To definitively identify Eta Car as the source of the hard X-ray emission, to examine how changes in the 2-10 keV band influence changes in the hard X-ray band, and to understand more clearly the mechanisms producing the non-thermal emission using new INTEGRAL observations obtained close to periastron. Methods: A Chandra observation encompassing the ISGRI error circle was analysed, and all other soft X-ray sources (including the outer shell of Eta Car itself) were discarded as likely counter-parts. New hard X-ray images of Eta Car were studied close to periastron, and compared to previous observations far from periastron. Results: The INTEGRAL component, when represented by a ...

2010-01-01

445

Energetic electrons in impulsive and extended solar flares as deduced from flux correlations between hard X-rays and microwaves  

Energy Technology Data Exchange (ETDEWEB)

The peak flux relationship between hard X-rays and microwaves from solar flares is studied using about 400 events simultaneously recorded with the hard X-ray burst spectrometer on the SMM satellite and the Nobeyama 17 GHz radiometer. The data indicate that the hard X-ray and microwave peak fluxes correlate best for X-ray energies of less than about 80 keV for impulsive flares and greater than about 360 keV for extended flares. By postulating that electrons responsible for microwave emission at 17 GHz are those emitting hard X-rays at these photon energies, it is concluded that: (1) in impulsive flares, microwaves at about 20 GHz are emitted mainly by electrons of less than about 200 keV from a layer through which the electrons stream down into the thick-target hard X-ray source; and (2) in extended flares, microwaves are emitted mainly by MeV electrons trapped ...

1988-01-01

446

DETECTION OF AN X-RAY PULSATION FOR THE GAMMA-RAY PULSAR CENTERED IN CTA 1  

International Nuclear Information System (INIS)

We report the detection of X-ray pulsations with a period of ?315.87 ms from the 2009 XMM-Newton observation for the radio-quiet ?-ray pulsar, LAT PSR J0007+7303, centered in the supernova remnant CTA 1. The detected pulsed period is consistent with the ?-ray periodicity at the same epoch found with the Fermi Gamma-ray Space Telescope. The broader sinusoidal structure in the folded light curve of the X-ray emission is dissimilar to that of the ?-ray emission, and the phase of the peak is about 0.5 shifting from the peak in the ?-ray bands, indicating that the main component of the X-rays originates from different sites of the pulsar. We conclude that the main component of the X-ray pulsation is contributed by the thermal emission from the neutron star. Although with a significantly different characteristic age, PSR J0007+7303 is similar to Geminga in emission properties of X-rays ...

2010-12-10

447

A Remarkable Low-Mass X-ray Binary within 0.1 pc of the Galactic Center  

CERN Document Server

Recent X-ray and radio observations have identified a transient low-mass X-ray binary (LMXB) located only 0.1 pc in projection from the Galactic center, CXOGC J174540.0-290031. In this paper, we report the detailed analysis of X-ray and infrared observations of the transient and its surroundings. Chandra bservations detect the source at a flux of F_X = 2e-12 erg cm^-2 s^-1 (2-8 keV). After accounting for absorption both in the interstellar medium and in material local to the source, the implied luminosity of the source is only L_X = 4e34 erg/s (2-8 keV; D=8 kpc). However, the diffuse X-ray emission near the source also brightened by a factor of 2. The enhanced diffuse X-ray emission lies on top of a known ridge of dust and ionized gas that is visible infrared images. We interpret the X-ray emission as scattered flux from the outburst, and determine that the peak ...

2005-01-01

448

radiation hardening and microstructure evolution in austenitic chromium-nickel steel under various type irradiation  

International Nuclear Information System (INIS)

A study was made into microstructure and hardening in austenitic stainless steel 0Kh18N10T irradiated with neon ions (230 MeV) and neutrons (E_n > 0.1 MeV). The experiments were accomplished using an external beam of U-400 cyclotron (Dubna) and EWA reactor (Poland). The dependences of tensile properties, hardening index, microstructure, dislocation density on damaging dose were determined. An attempt is made to reveal the correlation between an yield strength increment and defect cluster accumulation. The interpretation of variations of mechanical properties and microstructure under irradiation is given.

449

Study of somatic radiation effects in environment  

International Nuclear Information System (INIS)

A survey is presented of the consequences of the irradiation of the population with ionizing radiation. There is an increased incidence of leukemia in irradiated population groups. Among the inhabitants of Hiroshima and Nagasaki maximum death of leukemia was observed in the years 1951 to 1952. The results are summed up of the observation of carcinoma of the breast, lungs and bronchi, bones, and carcinoma of the thyroid. The effect of radiation on experimental animals is described. It was found that the scatter of the dependence of the incidence of various types of cancer on the dose equivalent apparently reflects differences in the biological mechanism of this incidence and that a proportional relationship cannot be expected between the primary damage of cells during irradiation and the actual manifestation of the disease. (E.S.).

450

Radiation-annealing hardening of vanadium  

International Nuclear Information System (INIS)

A study is made of the mechanical properties of vanadium irradiated with fast neutrons up to dose 8.6.10"-"4 dpa, as a function of the temperature of post-radiation annealing. The radiation-annealing hardening (RAH) effect is observed at 300"oC, in agreement with previous studies. It is established for the first time that RAH is accompanied by fall in ductility. A phenomenological model is described which explains the dependence of RAH on radiation dose and temperature, as well as on the content of chemically active alloying impurities. (author).

451

Induced mutation in Lupinus mutabilis sweet in Peru  

International Nuclear Information System (INIS)

Mutagenesis of Lupinus mutabilis was started at the UNA LM (Peru) to obtain mutants with low alkaloid content and early germination. Varieties SCG 25 and Lib 020 were irradiated with gamma radiation. The optimum dose for the SCG 25 variety was 15 Krad and for Lib 020 15 to 20 Krad. The relation between the plant height and radiation dose fits the quadratic polynomial model.

1984-04-01

452

Worker radiation doses in the United States at the dawn of the atomic era (1940--1960)  

Energy Technology Data Exchange (ETDEWEB)

Radiation doses to workers at the Manhattan Engineer District (MED) and US Atomic Energy Commission (AEC) sites due to external irradiation during 1940--1960 are reviewed. Categorized radiation dose data were available from AEC annual reports for some years. Annual individual radiation dose data for ten MED/AEC sites for all years were available from the US Department of Energy`s (DOE) Comprehensive Epidemiologic Data Resource (CEDR). These data are combined to produce an estimate of external collective dose equivalent to 172,000 person-rems (1720 person-Sv) for 1940--1960. During this period there were 41 overexposures, 19 criticality incidents, and 3 deaths due to acute radiation syndrome among several hundred thousand workers.

1994-06-01

453

SSRM characterisation of FIB induced damage in silicon  

International Nuclear Information System (INIS)

Scanning spreading resistance microscopy (SSRM) has been applied to study focused ion beam (FIB) induced damage in silicon in dependence on ion irradiation doses from 10"1"2 cm"-"2 to 2#centre dot#10"1"6 cm"-"2. Starting from the lowest dose, SSRM detects increasing spreading resistance (SR) with increasing dose. For doses from 2#centre dot#10"1"3 cm"-"2 to 4#centre dot#10"1"4 cm"-"2, a slight decrease of SR is measured whereas for higher doses SR again slightly increases. The results are explained by physical effects like decreased carrier mobility due to increased scattering, amorphisation of silicon and precipitation of implanted Ga ions. The results clearly prove that SSRM is well suited for the fast detection of ion beam induced damage with high lateral resolution.

2008-03-01

454

Radiation yield of oxygen-based radicals in hyperquenched glassy water gamma-irradiated at 77 K  

Energy Technology Data Exchange (ETDEWEB)

Hyperquenching of liquid water with cooling rates of 10{sup 6}-10{sup 7} K s{sup -1} yields glassy water. Upon {gamma}-irradiation at 77 K, the only paramagnetic species accumulating in hyperquenched glassy water are the hydroxyl and hydroperoxyl radicals. There are no hydrogen atoms or electrons seen by the ESR technique. For irradiation doses up to about 70 kGy, the relative contributions of hydroxyl and hydroperoxyl radicals to the total amount of paramagnetic species remain virtually constant. The total amount of paramagnetic species, n, is sublinear in dose, d, well approximated by n=8.55x10{sup 16}d{sup 0.8} for n in spin g{sup -1} and d in kGy.

1998-12-01

455

Effect of gamma radiation on chlorophylls contents, net photosynthesis and respiration of chlorella pyrenoidosa  

International Nuclear Information System (INIS)

The effect of five doses of gamma radiation: 10, 100, 500, 1000 and 5000 Gy on chlorophylls content, net photosynthesis and respiration of chlorella pyrenoidosa has been studied. A decrease in chlorophylls levels is produced after irradiation at 500, 1000 and 5000 Gy, being, at first 'b' chlorophyll affected to a greater extent than 'a' chlorophyll. Net photosynthesis and respiration decline throughout the time of the observations after irradiation, this depressing effect being much more remarkable for the first one. Net photosynthesis inhibition levels of about 30% have got only five hours post irradiation at a dose of 5000 Gy. (author).

456

Chemical Analysis of Solid-State Irradiated Human Insulin  

British Library Electronic Table of Contents (United Kingdom)

Purpose To study the chemical modifications induced upon irradiation of solid human insulin at radiosterilization doses and investigate the influence of the absorbed dose on radiolysis. Materials and Methods Volatile radiolytic products were monitored by gas chromatography coupled with mass spectrometry (GC-MS) and non-volatile products by two different high performance liquid chromatography (HPLC) methods: the formation of higher molecular weight proteins was assessed by size exclusion liquid chromatography whereas assays for related compounds and chemical potency tests were carried out using reverse-phase HPLC-UV. Conformational changes were investigated by measurements of circular dichroism. Results After gamma irradiation at 10?kGy, the recovery of insulin was 96.8%; higher molecular w...

2006-01-01

457

Mutual recombination and clusterization effect of the vacancy and interstitial barriers on radiation hardening materials  

British Library Electronic Table of Contents (United Kingdom)

There is proposed the nonlinear model of dose dependence saturation of the yield strength on the base of the vacancy and interstitial barrier interaction in this work. Processes of mutual recombination of vacancy and interstitial barriers and formation of vacancy and interstitial clusters are taken into consideration. In the framework of the model, the analytical equations corresponding to the evolution of the barrier densities and yield strength are obtained. It is shown that the yield strength of irradiated materials decreases with the increasing intensity of barrier recombination processes, the dependence being nonlinear. Also it is shown that the model is valid both for low doses and large doses on the stage of radiation hardening.

2009-01-01

458

Influence of wood extractives in the polymerization of methyl methacrylate by gamma irradiation  

International Nuclear Information System (INIS)

Those materials that can be extracted from pine or oak by ether, ethanol, methyl methacrylate (MMA), or benzene--alcohol all act as inhibitors in the #gamma# polymerization of MMA--wood composites. It was found that preirradiation of either the wood or of the wood--monomer combination reduces or eliminates the inhibitory effect. The most practical industrial solution to this problem is to increase the dose, thereby achieving high molecular polymer in the composite. However, the presence of a maximum in the molecular weight--dose curves means that each wood--monomer pair may have a different optimum dose.

1975-01-01

459

Toxicological safety evaluation of biomolecules and materials transformed by gamma irradiation  

Energy Technology Data Exchange (ETDEWEB)

In the bacterial reversion assay with S. typhimurium TA98, TA100, TA1535 and TA1537, gamma irradiated hyaluronic acid (10 and 50 kGy) did not induce a significant increase in the number of revertant colonies in the presence of S9 metabolic activation system. In chromosomal aberration tests with CHO cells, gamma irradiated hyaluronic acid (10 and 50 kGy) did not result in an increase in the frequency of chromosomal aberrations. In vivo mouse micronucleus assay, gamma irradiated hyaluronic acid (10 and 50 kGy) did not show an increase in the frequency of polychromatic erythrocytes with micronuclei. These results indicate that hyaluronic acids irradiated at 10 and 50 kGy did not show any genotoxic effects under these experimental conditions. In order to evaluate their possible subacute toxicity, the male and female of ICR mouse were given to methanol extract of 50 kGy irradiated red ...

2010-01-15

460

Measurement of skin dose in primary irradiation of maxillary sinus carcinoma  

Energy Technology Data Exchange (ETDEWEB)

Subcutaneous involvement frequently occurs in maxillary sinus carcinoma. Radical resection does not include removal of the skin at risk. In standard postoperative wedge-pair treatment plans, the surface dose is dependent upon beam weighting, beam energy, and patient contour. Thermoluminescent dosimetry (TLD) measurements were performed to evaluate the surface dose of patients undergoing postoperative irradiation of maxillary sinus carcinoma following primary resection. When 60 Gy was delivered to isocenter with a 45 degrees wedge pair and 6 MV photons with 1 cm bolus, the subcutaneous tissues at risk received {approximately} 30 Gy. Based upon presented TLD measurements, supplemental electron beam therapy to the subcutaneous tissues if primarily involved should be considered.

1991-03-01

461

TLD array for precise dose measurements in stereotactic radiation techniques  

International Nuclear Information System (INIS)

We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the ...

1996-12-01

462

Somatic and genetic effects of small doses of ionizing radiations in man  

International Nuclear Information System (INIS)

Estimations on the somatic and genetic effects of small doses of ionizing radiations in Man have been proposed by the Advisory Committee on the Biological Effects of Ionizing Radiation, set up by the U.S. National Academy of Sciences. They have been published in an important report, issued in 1972, from which we briefly analyze here the Chapter dealing with the somatic effects. Small doses of raditions are expected to promote only carcinogenic effects. After a rapid survey of the human experience on which the estimations are based, as regards the latent period of cancers, the plateau region (period of high risk) and the absolute and relative risk expressed per rem, per 10"6 persons, per year, for leukaemia (having the highest risk) and for the ''other cancers''. These estimations were obtained by linear extrapolation to the 1 rem level from observations made after irradiation at relatively high dose ...

1976-01-01

463

Measurement of spatial dose distribution with thermoluminescence sheet around high dose-rate intracavitary sup 60 Co sources  

Energy Technology Data Exchange (ETDEWEB)

A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL sheet was suggested to ...

1991-06-01

464

A technique for the fast calculation of three-dimensional photon dose distributions using the superposition model  

International Nuclear Information System (INIS)

Techniques for reducing computation time in 3D photon dose calculations are addressed with specific emphasis given to the convolution/superposition approach. A single polyenergetic superposition model calculating absorbed dose per incident photon fluence (Gy cm"2) was developed in terms of TERMA and a total energy deposition kernel (a total point spread function). A novel approach was devised for reducing calculation time. The method, named the CF method, was based on the use of a conventional, fast model (here a modified power-law method was used) for the generation of 3D dose distributions on a fine dose matrix. Superposition calculations were carried out on a coarse matrix and calculation speed was increased simply by reducing the number of calculations. A set of correction factors was derived on the coarse grid from the ratio of the dose values from superposition to those from ...

1997-08-01

465

Effects of antioxidants on lipid peroxide formation in irradiated synthetic diets  

International Nuclear Information System (INIS)

The effects of the antioxidants, vitamin E, propyl gallate, 2-t-butyl-4-methoxy phenol (BHA), 2,6-di-t-butyl-4-methoxy phenol (BHT), nor-dihydroguaiaretic acid (NDGA) and diphenyl-p-phenylene diamine (DPPD) in concentrations ranging between 0.001 per cent and 0.1 per cent have been tested on lipid peroxide formation in synthetic diet mixtures containing herring oil (10 per cent) mixed with starch (90 per cent) irradiated with #gamma#-ray doses of 100 to 2000 krad. On a weight basis NDGA, DPPD, BHA and BHT were most effective and vitamin E and propyl gallate were least effective. An antioxidant concentration of 0.01 per cent normally protected against peroxide formation after a dose of 500 krad but if the dose was increased to 1000 or 2000 krad, much higher doses of antioxidant, up to 0.1 per cent, were required to give protection. Antioxidants prevented peroxide developing during ...

466

Superconductivity in irradiated A-15 compounds at low fluences. II. Alpha-particle-irradiated Nb_3Sn and Nb_3Ge  

International Nuclear Information System (INIS)

The T/sub c/ behavior of vapor-deposited Nb_3Ge and Nb_3Sn is examined as a function of low-fluence alpha-particle irradiation. It is found that for Nb_3Sn with rho_0approx.15 #mu##OMEGA#-cm the T/sub c/ is insensitive to low doses of radiation, whereas Nb_3Ge with rho_0approx.50 #mu##OMEGA#-cm has its T/sub c/ depressed immediately with irradiation. It is suggested that the T/sub c/ behavior of A-15 superconductors in the regime of small dose is strongly influenced by the initial state of the sample. Furthermore, it is argued that the behavior of the T/sub c/ with dose can be qualitatively explained by considering a sharp structure in the density of states N(E), the smearing of which by defects leads to a depression in T/sub c/.

467

Body and brain development following exposure to "6"0Co #gamma#-irradiation during pregnancy in mice  

International Nuclear Information System (INIS)

We studied the dose-response effects of #gamma#-irradiation on the weight gains of the body and the brain in ICR mice exposed to various doses of "6"0Co #gamma#-irradiation ranging from 0 to 1.5 Gy on day 13 of pregnancy (E13). We found that 0.5 Gy #gamma#-irradiation caused a significant reduction in brain weight but not in body weight among 6-week-old mice. Higher doses (1.0, 1.5 Gy) seriously inhibited body and brain development, resulting in significantly low weights at 6 weeks of age. A significantly lower brain weight among fetuses exposed to 1.5 Gy was found as early as 24 hours after exposure, while significant reductions in the body weight of these same fetuses appeared 3 days after exposure. The effects of radiation on brain and body development were similar for both males and females. (author).

468

An evaluation of the pendulum technique of electron beam therapy  

International Nuclear Information System (INIS)

Electron beam therapy of lesions such as cutaneous metastatic carcinoma and reticulum cell sarcoma is performed via multiple portals for a wide irradiation field. However, the dose distribution in border areas is generally uneven, resulting in hot and cold dose areas depending on the intervals of the portals. We performed electron irradiation by the pendulum technique, especially on curved areas, and evaluated the technique in various respects. Pendulum electron beam irradiation is indicated when the length of the cone must be reduced in order to deliver the target volume near the skin surface as well as to avoid the occurrence of hot spots deep in the body. We prepared a 15cm rotating cone by cutting a 30cm fixed irradiation cone. The modification posed no disadvantages in terms of extent and flatness of the beam, or stability during rotation. After determining ...

469

Study of the electron beam irradiation effect on some properties of aromatic aliphatic copolyester films; Estudo do efeito da radiacao por feixe de eletrons nas propriedades de filmes de copoliester alifatico aromatico  

Energy Technology Data Exchange (ETDEWEB)

Biodegradable and green plastics are the new tendency in the world. The effect of the electron beam irradiation in aromatic aliphatic copolyester and the blend with corn starch films (Ecoflex{sup R} and Ecobras{sup R}) were studied by tensile strength at break, elongation at break, Scanning Electronic Microscopy (SEM), Fourier Transform Infrared Spectroscopy (FT-IR), Differential Scanning Calorimetry (DSC), crosslinking degree and biodegradability. The measurements in both, the machine direction and the transverse direction were made for mechanical tests. It was found that, the electron irradiation caused an increase in the strength at break of the blend with corn starch film, when doses of up to 10 kGy were applied. A significant decrease of the elongation at break of the blend with corn starch was observed at doses of 10 kGy and 40 kGy. It was not found important change in tensile properties for ...

2008-07-01

470

Study of the electron beam irradiation effect on some properties of aromatic aliphatic copolyester films  

International Nuclear Information System (INIS)

Biodegradable and green plastics are the new tendency in the world. The effect of the electron beam irradiation in aromatic aliphatic copolyester and the blend with corn starch films (Ecoflex"R and Ecobras"R) were studied by tensile strength at break, elongation at break, Scanning Electronic Microscopy (SEM), Fourier Transform Infrared Spectroscopy (FT-IR), Differential Scanning Calorimetry (DSC), crosslinking degree and biodegradability. The measurements in both, the machine direction and the transverse direction were made for mechanical tests. It was found that, the electron irradiation caused an increase in the strength at break of the blend with corn starch film, when doses of up to 10 kGy were applied. A significant decrease of the elongation at break of the blend with corn starch was observed at doses of 10 kGy and 40 kGy. It was not found important change in tensile properties for aromatic ...

471

Inherited Sterility in Progeny of Gamma-Irradiated Spiny Bollworm, Earias Insulana Boisd  

International Nuclear Information System (INIS)

The inherited sterility of the spiny bollworm Earias Insulana Boisd. Irradiated as parental male adults, with sub sterilizing doses of 100-200 Gy has been studied throughout three successive generations. In general, the female fecundity decreased at the three doses of irradiations (100, 150 and 200 Gy) throughout P_1. F_1, F_2 and F_3 generations as compared to control. The reduction was insignificant in all treatments with some exceptions at 200 Gy, in the parental generation and 150 and 200 Gy bin F_2 generation. Egg hatch of the parental generation was obviously reduced at 100, 150 and 200 Gy treatments as compared to the control. The progeny of F_1 males were evidently more sterile than their irradiated male parents. The effect continued in the F_2, population, however F_3 males almost regained their fertility. Irradiation of P_1 males did not greatly affect ...

1999-01-01

472

Effects of gamma-irradiation on the TL characteristics of pre-annealed natural ZrSiO{sub 4}  

Energy Technology Data Exchange (ETDEWEB)

By the use of thermoluminescence (TL) technique we have investigated the effects of gamma irradiation on the TL response of pulverised natural zircon (ZrSiO{sub 4}) crystals from the Jos Plateau area of Nigeria. Samples of the mineral that have been previously annealed were artificially irradiated to moderate gamma doses ranging from 0.7 to 4.9 Gy using {sup 60}Co gamma-source of the CERD. The natural TL glow curve of the sample showed a broad peak around 250 deg. C, the peak was however, found to be completely erased following heat treatment for 2 h at 400 deg. C. The TL glow curves of the artificially irradiated samples showed two overlapping glow peaks at about 112 deg. C (peak I) and at 156 deg. C (peak II) within the dose range utilised. We note that the natural TL peak appears to be different from the two observed in the artificially irradiated sample. The ...

2005-10-15

473

Effects of gamma-irradiation on the TL characteristics of pre-annealed natural ZrSiO_4  

International Nuclear Information System (INIS)

By the use of thermoluminescence (TL) technique we have investigated the effects of gamma irradiation on the TL response of pulverised natural zircon (ZrSiO_4) crystals from the Jos Plateau area of Nigeria. Samples of the mineral that have been previously annealed were artificially irradiated to moderate gamma doses ranging from 0.7 to 4.9 Gy using "6"0Co gamma-source of the CERD. The natural TL glow curve of the sample showed a broad peak around 250 deg. C, the peak was however, found to be completely erased following heat treatment for 2 h at 400 deg. C. The TL glow curves of the artificially irradiated samples showed two overlapping glow peaks at about 112 deg. C (peak I) and at 156 deg. C (peak II) within the dose range utilised. We note that the natural TL peak appears to be different from the two observed in the artificially irradiated sample. The TL ...

2005-10-01

474

Radiation 2006. In association with the Polymer Division, Royal Australian Chemical Institute. Incorporating the 21st AINSE Radiation Chemistry Conference and the 18th Radiation Biology Conference, conference handbook  

International Nuclear Information System (INIS)

Full text: An adaptive response is a decreased biological effect induced by a priming radiation dose given prior to a challenge dose. Adaptive responses contradict the linear-nothreshold model of risk estimation. The pKZ1 mouse chromosomal inversion assay is an extremely sensitive assay for studying the mutagenic effect of low dose radiation. A non-linear dose response for chromosomal inversion has been observed in pKZ1 spleen and prostate after a single whole body irradiation with doses between 1?Gy and 10mGy. Doses between 5-10?Gy resulted in an induction in inversions and doses between 1-10mGy resulted in a reduction below endogenous inversion frequency. These results suggest that doses in the 1-10 mGy range cause host responses which overcompensate by not only preventing inversions that would ...

2006-04-01

475

Very low-dose hyper-radiosensitivity: impact for radiotherapy of micrometastases; Hyperradiosensibilite aux tres faibles doses: impact en radiotherapie des micrometastases  

Energy Technology Data Exchange (ETDEWEB)

Radio-biologists have pointed out a novel radiobiological phenomenon observed in many tumor and normal cell lines: hyper-radiosensitivity to very low-dose (H.R.S.) followed by induced radioresistance (I.R.R.) after a threshold dose of 0.1-0.3 Gy that depends on the cell line. Radioresistance at high dose (i.e. higher than 0.5 Gy) and metastatic potential of tumor cells are likely major factors of failure in radiotherapy. A careful review of literature suggests that: 1) radiotherapy does not increase the metastatic potential of tumor cells; 2) radioresistance at high dose and metastatic potential are not related. However, inside a given tumor cell line, highly metastatic clones may elicit more cells showing H.R.S; or are more radiosensitive at high dose than poorly metastatic ones. Recent data obtained from molecular techniques (comet and immunofluorescence assays) applied to single ...

2007-09-15

476

Reduction in radiation-induced brain injury by use of pentobarbital or lidocaine protection  

Energy Technology Data Exchange (ETDEWEB)

To determine if barbiturates would protect brain at high doses of radiation, survival rates in rats that received whole-brain x-irradiation during pentobarbital- or lidocaine-induced anesthesia were compared with those of control animals that received no medication and of animals anesthetized with ketamine. The animals were shielded so that respiratory and digestive tissues would not be damaged by the radiation. Survival rates in rats that received whole-brain irradiation as a single 7500-rad dose under pentobarbital- or lidocaine-induced anesthesia was increased from between from 0% and 20% to between 45% and 69% over the 40 days of observation compared with the other two groups (p less than 0.007). Ketamine anesthesia provided no protection. There were no notable differential effects upon non-neural tissues, suggesting that pentobarbital afforded protection through modulation of ambient neural ...

1990-05-01

477

Influence of different chemical elements on irradiation-induced hardening embrittlement of RPV steels  

International Nuclear Information System (INIS)

Fe-Cu binary alloys are often used to mimic the behaviour of reactor pressure vessel steels. Their study allows identifying some of the defects responsible for irradiation-induced hardening. But recently the influence of manganese and nickel in low-Cu steels has been found to be important as well. In contrast with existing models found in the literature, which predict that hardening saturates after a certain dose, Fe alloys containing nickel and manganese irradiated in a material test reactor (BR2) show a continuous increase of hardening, up to doses equivalent to about 40 years of operation. Considerations based on positron annihilation spectroscopy analyses suggest that the main objects causing hardening in Cu-free alloys are most probably self-interstitial clusters decorated with manganese. In low-Cu reactor pressure vessel steels and in Fe-CuMnNi alloys, the main effect is still due to Cu-rich ...

2008-09-01

478

Effects of an acute dose of gamma radiation exposure on stem diameter growth, carbon gain, and biomass partitioning in Helianthus annuus  

Energy Technology Data Exchange (ETDEWEB)

Nineteen-day-old dwarf sunflower plants (Helianthus annuus, variety NK894) received a variable dose (0-40 Gy) from a cobalt-60 gamma source. A very sensitive stem monitoring device, developed at Battelle's Pacific Northwest Laboratories, Richland, Washington was used to measure real-time changes in stem diameter. Exposure of plants caused a significant reduction in stem growth and root biomass. Doses as low as 5 Gy resulted in a significant increase in leaf density, suggesting that nonreversible morphological growth changes could be induced by very low doses of radiation. Carbohydrate analysis of 40-Gy irradiated plants demonstrated significantly more starch content in leaves and significantly less starch content in stems 18 days after exposure than did control plants. In contrast, the carbohydrate content in roots of 40-Gy irradiated plants were not significantly different ...

1988-05-25

479

Applications or radiation polymerization hardening to composites  

International Nuclear Information System (INIS)

Comprehensive investigation has been made into the application of the polymerization hardening by radiation, particularly electron beam, to the composites of polymers and other materials. The report is divided into four parts, namely 1) characteristics and problems of the reaction of curing by radiation polymerization, 2) improvement of the bonding capability of high molecular weight materials, 3) bonding by radiation, and 4) composites made by the impregnation and polymerization hardening of monomers. The first part includes the effects of dose rate, temperature rise during the hardening, the peculiarity of electron beam irradiation at high dose rate, reaction environment and additive effects. Main conclusions are as follows: caution must be taken to the amount of residual double bonds because they affect the quality of hardened polymers; the polymerization hardening reaction at high dose rate cannot ...

1976-01-01

480

Measurement of K x-ray intensity ratio of tin, gadolinium and dysprosium  

International Nuclear Information System (INIS)

Full text: Measurement of K_#beta# to K_#alpha# x-ray intensity ratios are important not only in the field of atomic physics, radiation physics and medical physics, but also to test the validity of assumptions made in the theoretical prediction. The intensity ratios can also give information on the effect of physical and chemical environment of the element in the compound. Many investigators have adopted a single and double reflection geometries to measure the K_#beta# to K_#alpha# x ray intensity ratios to understand the effect of physical and chemical environment on x-ray fluorescence. The targets are excited by a radioactive source of having activity of the order 100 MBq. in order to carry out accurate measurement K_#beta# to K_#alpha# x-ray intensity ratios, we have develop 2#pi# geometrical configuration method : placing a target right on the surface of the detector facing the ...

2003-11-01

481

Test of electron beam technology on Savannah River Laboratory low-activity aqueous waste for destruction of benzene, benzene derivatives, and bacteria  

Energy Technology Data Exchange (ETDEWEB)

High energy radiation was studied as a means for destroying hazardous organic chemical wastes. Tests were conducted at bench scale with a {sup 60}Co source, and at full scale (387 l/min) with a 1.5 MV electron beam source. Bench scale tests for both benzene and phenol included 32 permutations of water quality factors. For some water qualities, as much as 99.99% of benzene or 90% of phenol were removed by 775 krads of {sup 60}Co irradiation. Full scale testing for destruction of benzene in a simulated waste-water mix showed loss of 97% of benzene following an 800 krad dose and 88% following a 500 krad dose. At these loss rates, approximately 5 Mrad of electron beam irradiation is required to reduce concentrations from 100 g/l to drinking water quality (5 {mu}g/l). Since many waste streams are also inhabited by bacterial populations which may affect filtering operations, the effect of ...

1993-08-01

482

Electrical conductivity of the ceramic AIN under irradiation  

Energy Technology Data Exchange (ETDEWEB)

Aluminum nitride has been proposed as electrically insulating coating in connection with blankets made of vanadium alloys. Irradiations were performed with an applied DC electric field of 100 kV/m, using a 104 MeV {alpha}-particle beam. The dose achieved were 0.1 dpa at 300 C, 0.05 dpa at 400 C, and 0.06 dpa at 500 C. The out-of-beam conductivity {sigma}{sub 0} decreased at all temperatures employed during early stage of irradiation. Before 0.02 dpa had been reached, {sigma}{sub 0} dropped to low values of typically (2-4) x 10{sup -11} ({Omega} m){sup -1}. Although a moderate increase can be observed during further irradiation, {sigma}{sub 0} remained below the initial value of the unirradiated specimen for all temperatures. That is, there is no significant evidence for radiation induced electrical degradation. The in-beam conductivity {sigma}, measured continuously during ...

1996-10-01

483

Effects of gamma irradiation on medicinal plants and spices (2): Piper cubeba, piper nigrum, piper retrofractum, amomum cardamomum, and myristica fragrans  

Energy Technology Data Exchange (ETDEWEB)

Effects of gamma irradiation on essential oils of five medicinal plants i.e. dried seeds of piper cubeba(cubeb), piper nigrum(black pepper), piper retrofractum, amomum cardamomum(cardamom) and myristica fragrans(mace), packed in low density polyethylene bag of 0.13 mm thickness have been investigated. After being irradiated at doses of 5 and 10 kGy, a part of the samples was analysed, and the rest were stored for six months at temperature of 30 +- 2 degC, and humidity ranging from 70 to 95%. The essential oil characteristics of control, irradiated and six month stored samples were analysed using infrared and ultraviolet spectrophotometers, HPLC, GLC and refractometer. Other parameters observed were moisture content and essential oil content of the samples. Results showed that irradiation up to a dose of 10 kGy do not give any significant effect on these ...

1983-12-01

484

Effect of chronic fractionated low-dose gamma irradiation on division potential of human embryonic cells in vitro  

Energy Technology Data Exchange (ETDEWEB)

We investigated the in vitro phenotypic transformation of human embryo (HE) cells that were repeatedly irradiated (7.5 cGy once a week) throughout their life-span. Irradiation was repeated until the cells had accumulated 195 cGy (equivalent to the 26th passage). Samples of cells were assayed for survival by colony formation, as well as for mutation at the hypoxanthine guanine phosphoribosyl transferase (HGPRT) locus and for transformation by focus formation. The life-span (mean number of population doublings) of multiply irradiated cells with a total dose of 97.5 cGy was slightly but significantly prolonged over that of controls. After HE cells had accumulated 195 cGy, the maximum number of divisions increased to 130-160% of the number in non-irradiated control cells. Transformed foci were not observed until cells had accumulated 97.5 cGy, and then increased with the increasing ...

1991-12-01

485

EPR investigation of some irradiated traditional oriental spices  

International Nuclear Information System (INIS)

The X-band EPR spectra of unirradiated and "6"0 Co gamma ray irradiated cardamom (Elettaria cardamomum L. Maton, Zingiberaceae), ginger ((Zingiber officinale Rosc., Zingiberaceae), saffron (Crocus sativus L., Iridaceae), and curry have been investigated at room temperature. All unirradiated spices presented a weak resonance line with g-factors around free-electron ones, most probably due to the presence of semiquinones, previously reported to have paramagnetic properties. After gamma ray irradiation at absorbed dose up to 11.3 kGy we have noticed in all spices the presence of complex EPR spectra consisting of a superposition of at last two different paramagnetic species whose amplitude increase monotonously with the absorbed dose. A 100 deg. C isothermal annealing of 11.3 kGy irradiated samples has shown a differential reduction of amplitude of various components that form the ...

2005-09-13

486

Changes of hypoxia inducible factor-1 ? in hepatoma cells irradiated by gamma ray and their mechanism  

International Nuclear Information System (INIS)

This paper reports regulation of hypoxia inducible factor-1 ? (HIF-1 ?)in hepatoma cells by irradiation. Cobalt chloride (CoCl2), a chemical mimic agent for hypoxia research, was utilized to induce the stable expression of HIF-1 ? in HepG2 cells. The HepG2 cells were irradiated to different doses to observe the changes of HIF-1 ?. The level of intracellular reactive oxygen species (ROS) was assayed by fluorescent microscope and flow cytometry (FCM). The results showed that there were obvious changes in expression of HIF-1 ? after HepG2 cells exposed to radiation, and the changes were positively related with the irradiation dose from 1 Gy to 5 Gy. Moreover, contents of incellular ROS were negatively correlated with above levels of HIF-1 ? from 1 Gy to 3 Gy. The results indicate that irradiation may enhance hypoxic cells HIF-1 ?, and the reduction of intracellular ...

2007-10-01

487

Isolating the effect of radiation-induced segregation in irradiation-assisted stress corrosion cracking of austenitic stainless steels  

International Nuclear Information System (INIS)

Post-irradiation annealing was used to help identify the role of radiation-induced segregation (RIS) in irradiation-assisted stress corrosion cracking (IASCC) by preferentially removing dislocation loop damage from proton-irradiated austenitic stainless steels while leaving the RIS of major and minor alloying elements largely unchanged. The goal of this study is to better understand the underlying mechanisms of IASCC. Simulations of post-irradiation annealing of RIS and dislocation loop microstructure predicted that dislocation loops would be removed preferentially over RIS due to both thermodynamic and kinetic considerations. To verify the simulation predictions, a series of post-irradiation annealing experiments were performed. Both a high purity 304L (HP-304L) and a commercial purity 304 (CP-304) stainless steel alloy were irradiated with 3.2 MeV protons at ...

2002-04-01

488

Consumer's evaluation of the effects of gamma irradiation and natural antioxidants on general acceptance of frozen beef burger  

International Nuclear Information System (INIS)

The effect of addition of rosemary and oregano extracts on the sensory quality of irradiated beef burger was investigated. Batches of beef burgers were prepared with 400 ppm of rosemary or oregano extract and a group prepared with 200 ppm of synthetic butyl-hydroxytoluene (BHT)/butyl-hydroxy-anisol (BHA) was used as a control. Half of each formulation was irradiated at the maximum dose allowed for frozen meat (7 kGy). Samples were kept under frozen conditions (-20 deg. C) during the whole storage period, including during irradiation. Two analyses were performed after 20 and 90 days to verify the influence of the addition of the different types of antioxidants and the effect of irradiation and storage time on the acceptance of the product. Thirty-three and thirty-four untrained panelists were invited to participate in the first and second test, respectively. A structured hedonic ...

2009-04-01

489

Irradiation of Langmuir-Blodgett multilayer preparations of phospholipids and a fatty acid. Pt. 1; Effect of UV radiation  

Energy Technology Data Exchange (ETDEWEB)

Langmuir-Blodgett (LB) preparations containing stacked monolayers of phospholipids or stearic acid were irradiated with UV light and the electric conductance perpendicular to the planes of the monolayers was measured. There was no observable change of conductance when LB preparations of stearic acid were irradiated. For LB preparations of phospholipids, a rise of conductance, dependent on dose rate, was observed, reaching an equilibrium level after a few hours. After irradiation the conductance fell with a temperature-dependent time constant, and eventually reached a final level a little above the initial value. A three-state model is proposed for the LB phospholipid preparations. This suggests that the absorption of one photon raises a molecule from the ground to an excited state; and the absorption of a second photon carries it into a damaged but repairable or metastable state. (author).

1992-12-01

490

GaAs pattern etching with little damage by a combination of Ga"+focused-ion-beam irradiation and subsequent Cl_2 gas etching  

International Nuclear Information System (INIS)

Pattern formation on GaAs by Ga"+ focused-ion-beam (FIB) irradiation and subsequent Cl_2 gas etching was carried out. A higher etch rate at the FIB-irradiated area compared with that not irradiated under Cl_2 gas allows pattern construction without a mask process. The degree of residual crystal damage was evaluated using photoluminescence (PL) intensity measurements. The PL intensity in the etched region was one order of magnitude stronger than that of FIB sputtering, and was several times stronger than that of Ga"+ FIB-assisted Cl_2 etching. Etch depths of the order of 100 nm, which is five times deeper than that obtained by FIB sputtering, were efficiently performed using moderate Ga"+-ion doses.

491

GaAs pattern etching with little damage by a combination of Ga sup + focused-ion-beam irradiation and subsequent Cl sub 2 gas etching  

Energy Technology Data Exchange (ETDEWEB)

Pattern formation on GaAs by Ga{sup +} focused-ion-beam (FIB) irradiation and subsequent Cl{sub 2} gas etching was carried out. A higher etch rate at the FIB-irradiated area compared with that not irradiated under Cl{sub 2} gas allows pattern construction without a mask process. The degree of residual crystal damage was evaluated using photoluminescence (PL) intensity measurements. The PL intensity in the etched region was one order of magnitude stronger than that of FIB sputtering, and was several times stronger than that of Ga{sup +} FIB-assisted Cl{sub 2} etching. Etch depths of the order of 100 nm, which is five times deeper than that obtained by FIB sputtering, were efficiently performed using moderate Ga{sup +}-ion doses.

1990-12-15

492

Cryo-irradiation as a terminal method for the sterilization of drug aqueous solutions  

British Library Electronic Table of Contents (United Kingdom)

The aim of this study is to evaluate the specificities of the irradiation of drugs in frozen aqueous solution. The structures of the degradation products were determined to gain insight into the radiolysis mechanisms occurring in frozen aqueous solutions. Metoclopramide hydrochloride and metoprolol tartrate were chosen as models. The frozen solutions were irradiated at dry ice temperature by high energy electrons at various doses. The drug purity (chemical potency) and the radiolysis products were quantified by HPLC-DAD. Characterization of the degradation products was performed by LC-APCI-MS-MS. The structures of the radiolysis products detected in irradiated frozen aqueous solutions were compared to those detected in solid-state and aqueous solutions (previous studies). For both metoclop...

2008-01-01

493

Preliminary study of the application of natural olivine in Cenozoic dating  

Energy Technology Data Exchange (ETDEWEB)

The study investigated the luminescence behaviour of natural olivine to discuss the potential for Cenozoic (quaternary) dating. The UV-blue thermoluminescence (TL) glow curves of irradiated olivines have a resolved peak at 190 deg. C and other peaks at higher temperature at lower dose levels, and broad signals around 275-310 and 375-400 deg. C at higher dose levels. The UV-blue TL increases with additional laboratory dose to {approx}1.6kGy within a plateau temperature region, suggesting the possibility of dosimetry and Cenozoic dating. Both infrared stimulated luminescence (IRSL) and blue light stimulated luminescence (BLSL) were detected from laboratory-irradiated olivines although the BLSL was weaker than the IRSL. Furthermore, post-BL IRSL was detected but post-IR BLSL was not observed. Therefore, IR stimulation is recommended for optically stimulated luminescence measurements ...

2006-08-15

494

INTRINSIC DOSIMETRY: A POTENTIAL NEW TOOL FOR NUCLEAR FORENSICS INVESTIGATIONS  

International Nuclear Information System (INIS)

Thermoluminescence (TL) dosimetry was used to measure dose effects on the raw stock material of borosilicate container glass from different geographical locations. Effects were studied at times up to 60 days post-irradiation at doses from 0.15 to 20 Gy. The minimum detectable dose using this technique was estimated to be 0.15 Gy which is roughly equivalent to a 24 hr irradiation 1 cm from a 50 ng source of 60Co. Two peaks were identified in the TL glow curve, a relatively unstable peak around 125 C and a more stable peak around 225 C. Differences in TL glow curve shape and intensity were also observed for the glasses from different geographical origins. We investigate radiation induced defects in glass to further develop the technique of intrinsic dosimetry - the measurement of the total absorbed dose received by the walls of a container holding radioactive ...

2010-07-11

495

Experimental and theoretical studies of nuclear generation of ozone from oxygen and oxygen--sulfur hexafluoride mixtures  

International Nuclear Information System (INIS)

A series of experimental measurements of the yield of O_3 in nuclear-induced O_2 and O_2-SF_6 discharges are reported. The discharges were created by bombardment with energetic particles from the "1"0B(n,#alpha#)"7Li reaction. Continuous irradiation at dose rates of 10"1"5--10"1"7 eV cm"-"3 s"-"1 and pulsed irradiation (--10 ms FWHM) at a peak dose rate of --10"2"0 eV cm"-"3 s"-"1 were conducted. At the lower dose rates, the addition of SF_6 generally increased the ozone yield due to the slowing of ozone destruction by negative oxygen and ozone ions. In contrast, at the high dose rates, the ozone concentration decreased due to SF_6 suppression of atomic oxygen formation by ion--ion recombination. A numerical model was developed and tested against experimental conditions. This model indicates that the steady-state ozone concentration was limited by the reaction ...

496

Use of x-ray imaging for evaluation of superconducting ceramics fabricated by PIT method  

Energy Technology Data Exchange (ETDEWEB)

High-spatial-resolution microfocus-based X-ray imaging technology, both real-time and film, has been used to study the thickness variation that occurs in the oxide core of silver-sheathed BSCCO ribbons produced by the powder-in-tube method. This thickness variation (also called ``sausaging``) occurs during incremental rolling and degrades the critical current densities of the ribbons. Using X-ray image data the authors determined the onset and severity of sausaging. Onset occurred at a ribbon thickness of 203 {micro}m, and the severity increased with subsequent rolling reductions. Scanning electron microscopy was used to confirm the X-ray image data. X-ray imaging provides several advantages over more traditional methods for characterizing the superconductors such as optical or scanning electron microscopy. The X-ray imaging provides nondestructive information about the entire width ...

1993-08-01

497

Effect of {gamma}-radiation on migration behaviour of dioctyladipate and acetyltributylcitrate plasticizers from food-grade PVC and PVDC/PVC films into olive oil  

Energy Technology Data Exchange (ETDEWEB)

Food-grade PVC and PVDC/PVC films containing 28.3% dioctyladipate (DOA) and 5.0% acetyltributylcitrate (ATBC) plasticizers, respectively, were brought into contact with olive oil and were irradiated with {gamma}-radiation [{sup 60}Co] at doses equal to 4 kGy and 9 kGy corresponding to `cold pasteurization`. Irradiation was carried out at 8-10 C and samples were subsequently stored at 4-5 C. Contaminated oil samples were analysed for DOA and ATBC at intervals between 7 h and 97 h of contact, using an indirect GC method. Identical non-irradiated (control) samples were also analysed for DOA and ATBC content. Results showed no statistically significant differences in migrated amounts of DOA and ATBC between irradiated and non-irradiated samples. Neither were differences observed between samples irradiated at 4 kGy and 9 kGy. This was supported ...

1995-12-31

498

Development of food preservation and processing techniques by radiation  

International Nuclear Information System (INIS)

Development of food preservation and processing techniques by radiation was performed. Gamma irradiation at 2-10 kGy is considered to be an effective method to control pathogenic bacteria in species including Escherichia coli O157:H7. Gamma irradiation at 5 kGy completely eliminated pathogenic bacteria in beef. Gamma irradiation at such doses and subsequent storage at less than 4 deg C could ensure hygienic quality and prolong the microbiological shelf-life resulting from the reduction of spoilage microorganisms. Gamma irradiation on pre-rigor beef shortens the aging-period, improves tenderness and enhances the beef quality. And, a new beef processing method using gamma irradiation, such as in the low salt sausage and hygienic beef patty was developed. Safety tests of gamma-irradiated meats(beefs: 0-5 kGy; porks: 0-30 kGy) in areas such as ...

1988-04-18

499

The result of Alanine/ESR dosimetry at Wolsung unit 1  

International Nuclear Information System (INIS)

It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate dose, two ...

2008-10-01