Scatter correction is crucial to the quality of reconstructed images in x-ray cone-beam computed tomography (CBCT). Most of existing scatter correction methods assume smooth scatter distributions. The...Full Text Available
In Spiral CT, the pitch is the ratio of the distance to tabletop travels per 360 degrees rotation to nominal slice width, expressed in mm. Performing Spiral CT examination with pitch 2 allows to reduce examination time, exposure and contrast dose, and X-ray tube overload. The authors investigated the yield of pitch 2 in lung parenchyma studies, particular relative to diagnostic image quality.
The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...
The most important commercialized methods of attenuation correction in SPECT are based on attenuation coefficient map from a transmission imaging method. The transmission imaging system can be the linear source of radioelement or a X-rayCT system. The image of transmission imaging system is not useful unless to replacement of the attenuation coefficient or CT number with the attenuation coefficient in SPECT energy. In this paper we essay to evaluate the validity and estimate the error of the most used method of this transformation. The final result shows that the methods which use a linear or multi-linear curve accept a error in their estimation. The value of mA is not important but the patient thickness is very important and it can introduce a error more than 10 percent in the final result.
A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. The authors established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging
The patch and voxel methods are representative examples of the ways in which multi-slice images may be displayed three-dimensionally by means of computer-graphics. Each of them have advantages and disadvantages and they are mutually complementary. We have developed algorithms for a modified voxel method which incorporates the advantages of the patch methods. We have applied this to the three-dimensional image display of brain tumor with excellent results. The three-dimensional reconstructions used for clinical application in this study were derived from X-rayCTimages.
Computed tomography (CT) has been incorporated in an industrial Diode-Array Digital Radiography (DADR) system. An input data size of 512 pixel points x 400 projections yielded a 400x400 output image matrix. Reconstruction algorithms used are the filtered backprojection (FBP) and the direct Fourier reconstruction (DFR). Various filters were used in the FBP reconstruction process and their effects on image quality were evaluated. A spatial resolution of 100 {mu}m was measured with a block of plates and a minimum detectable feature size in the range of 10-100 {mu}m was measured using thin wires. Industrial specimens imaged have included ceramic samples, ball bearings and integrated circuits. A number of engineering problems have been solved, such as adjustment of the X-ray source, centering of the rotator spindle in the view field and beam-hardening corrections. (orig.).
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed ...
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed ...
Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)
The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated ...
X-rayimaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging
There is significant interest in using computed tomography (CT) for in vivo imaging applications in mouse models of disease. Most commercially available mouse x-rayCT scanners utilize a charge-coupled device (CCD) detector coupled via fibre optic taper to a phosphor screen. However, there has been little research to determine if this is the optimum detector for the specific task of in vivo mouse imaging. To investigate this issue, we have evaluated four detectors, including an amorphous selenium (a-Se) detector, an amorphous silicon (a-Si) detector with a gadolinium oxysulphide (GOS) screen, a CCD with a 3:1 fibre taper and a GOS screen, and a CCD with a 2:1 fibre taper and both GOS and thallium-doped caesium iodide (CsI:Tl) screens. The detectors were evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), detective quantum efficiency (DQE), ...
ASTROSAT, India's first dedicated astronomy satellite is slated for launch in 2007. The primary science objective of ASTROSAT is to explore the Universe using broad-band instruments covering optical, UV, soft X-ray and hard X-ray studies
Phase contrast X-rayimaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and ...
Selective alveolo-bronchography (SAB) has been routinely used to evaluate anatomical changes in the bronchiole and its distal air spaces. A narrowing of the bronchiole and abnormal pooling of contrast medium in the destroyed air space are the prime findings. Since the object of radiography is extremely thin, direct magnification radiography is mandatory to obtain radiologic details. However, the problem with this technique is that radiographic quality varies depending upon the size of the patient and the concentration of contrast medium to be introduced in the lung. This study had two goals. One was to improve the image quality of SAB by Fuji Computed Radiography (FCR). FCR provides radiographs with a good contrast and stable density throughout a wide range of exposure factors which occur in the use of SAB. The other goal was to separately evaluate morphological abnormalities in the outer and inner zones of the lung using X-ray ...
As yet, the role of Computed Tomography (CT) as a routine imaging technique in the staging and follow-up of thoracic Hodgkin's disease has not been assessed. The authors reported the results obtained in 120 patients affected with thoracic Hodgkin's disease, staged and followed by means af chest X-rays and CT. CT better identified intrathoracic involvement of mediastinal nodes, of lung parenchyma, of pleura, and of pericarcial and chest walls in 54/120 patients (45%), with staging modifications in 18 (15%) of them only. Treatment was changed only in 12 patients (19%) where radiation therapy had been planned. The clinical value of the additional information yielded by CT was especially evident in the follow-up: CT allowed the correct evaluation of persistent/ recurrent disease in 51/117 patients (43.5%), a figure high enough to suggest the use ...
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,{theta}) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.
A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,#theta#) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.
Both x-ray and optical cone-beam CT (CBCT) scanners are limited by scattered photons that contaminate the primary images. Transparent radiochromic gels and plastics are anticipated to produce less scattering than polymerization gels and hence result in reconstructed dose distributions with greater contrast and dynamic range. Four methods of scatter measurement were investigated to quantify scatter fractions using an in-house optical CBCT scanner. The methods consisted of generating either 'coin' shadows or primary beamlets in transmission images. The four methods generated similar results of 10% scatter fractions in gel transmission images for this particular scanner configuration with both leuco crystal violet and carbon black micelle gels. The scatter contributions were distributed as 5% from micelle gel, 2% from Teflon wall, 2% from refractive index matching ...
An examination of the noise of polycrystalline silicon thin film transistors, in the context of flat panel x-rayimager development, is reported. The study was conducted in the spirit of exploring...Full Text Available
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-rayimaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-rayimaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.
Based on a recently introduced phase X-rayimaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in ...
MRI is a powerful diagnostic modality of expanding availability. Equipment and installation amount to nearly $2M per site. An important component of diagnostic efficacy is not just equipment costs but also replacement costs, which for x-rayCT amount to 14-20% of the purchase cost per year; and in the early years of that technology reached 30-50%. The authors show how design choices made during the RandD stages of MRI development have allowed them to improve system performance parameters such as data reconstruction, archiving and display speeds, computational capabilities, operator interfaces, imaging sequence flexibility and signal-to-noise levels. Over the last four years these improvements have been made at a retrofit cost well below the target of 6-7% of the purchase price per year.
The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while ...
The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while ...
The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while ...
This paper describes Fuji computed radiography (FCR) of Fuji Film for NDT (non-destructive testing). Imaging plate (IP) is a two-dimensional detector of X-ray, and shows higher photographic sensitivity than X-ray film. The output emission of IP provides a good linear relationship to X-ray intensity in a wide intensity range. When this emission can be digitized, the X-ray intensity can be also digitized. IP is applied to NDT as an inspection using X-ray. FCR provides higher photographic sensitivity than the conventional X-ray film method, which results in one-fifth to one-twentieth of irradiation time. Images with stable density can be obtained independent of the intensity. Since IP has a wide dynamic range, the variation of X-ray intensity of 1:500 can be expressed in a single ...
The effect of anode length and operating gas pressure on the x-ray emission from a nitrogen-filling modified plasma focus device has been investigated. The time-resolved investigation of xray was carried out by using a five-channel photodiode x-ray spectrometer. The maximum x-ray yield is seen to increase with the increase in the anode length from 110 to 125 mm. Further increase in the anode length to 130 mm causes the x-ray yields to decrease. The highest x-ray yield of 4.5 J into 4#pi# sr was found for 125 mm anode length, which is 0.2% of the input energy. The average x-ray photon energy was estimated by using half-value thickness method and found to be 8.4 keV. The electron temperature of the plasma was estimated to be around 3 keV by x-ray intensity ratio method. The space-resolved ...
Differential phase-contrast X-rayimaging has been performed in a Talbot-Lau configuration, where a multiline X-ray source was used instead of a combination of a hard-X-ray multiple slit and a normal focus X-ray generator. When the multiple slit is used, a high aspect ratio structure is needed and slit width should be below 10 ?m for its function. The fabrication and use of such a multislit can be omitted using the presented configuration. The multiline X-ray source was developed by making grooves on a tungsten rotating anode, which was irradiated by an electron beam to generate X-rays. An array of 10?m line sources with a pitch of 30?m was formed and combined with a 4.5 ?m pitch phase grating and a 5.3 ?m pitch amplitude grating to generate differential phase contrast. With a total exposure time of 40 s, a differential phase ...
Multimodality imaging with PET/CT and SPECT/CT has become commonplace in clinical practice and in preclinical and basic medical research. Do other combinations of imaging modalities have a similar...Full Text Available
Currently, x-ray mammography is the method of choice in breast cancer screening programmes. As the mammography technology moves from 2D imaging modalities to 3D, conventional computational phantoms do not have sufficient detail to support the studies of these advanced imaging systems. Studies of these 3D imaging systems call for a realistic and sophisticated computational model of the breast. DeBRa (Detailed Breast model for Radiological studies) is the most advanced, detailed, 3D computational model of the breast developed recently for breast imaging studies. A DeBRa phantom can be constructed to model a compressed breast, as in film/screen, digital mammography and digital breast tomosynthesis studies, or a non-compressed breast as in positron emission mammography and breast CT studies. Both the cranial-caudal and mediolateral oblique views can be modelled. The ...
In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).
An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.
High-spatial-resolution microfocus-based X-rayimaging technology, both real-time and film, has been used to study the thickness variation that occurs in the oxide core of silver-sheathed BSCCO ribbons produced by the powder-in-tube method. This thickness variation (also called ``sausaging``) occurs during incremental rolling and degrades the critical current densities of the ribbons. Using X-rayimage data the authors determined the onset and severity of sausaging. Onset occurred at a ribbon thickness of 203 {micro}m, and the severity increased with subsequent rolling reductions. Scanning electron microscopy was used to confirm the X-rayimage data. X-rayimaging provides several advantages over more traditional methods for characterizing the superconductors such as optical or scanning electron microscopy. The ...
Digital radiography for diagnosis of chest diseases using Fuji Computed Radiography (FCR) was evaluated. The results were as follows; 1. Compared to the conventional chest X-ray films, various types of image enhancement could be made by manipulation of the digital information such as tone conversion, spatial frequency modification etc. 2. Digital radiography lessens the X-ray exposure dose and will ultimately permit speedy transmission of image data from outlying clinics to central processing hospitals. 3. Digital radiographic images are useful in chest X-ray diagnosis especially in mass surveys for lung cancer and in primary care medicine because of its full imaging capability. (author).
Computed tomography was performed on 5 patients with chronic cerebral paragonimiasis. CT showed solitary or multiple, amorphous, round, or oval calcifications, and ventricular enlargement in all 5 cases. A large low-density area is also found in 4 of the 5 cases. These CT findings are compatible with previously reported findings of simple X-ray films of the skull, pneumoencephalography, and pathological studies. (author).
A portable X-rayimage system is described comprising: (a) a base assembly including panels and hinges joining the panels together along edges, and compression stops for biasing the hinges to compensate for the weight of payload when mounted on the base assembly, the compression stops being located for interaction with the hinges for biasing the panels to exhibit upward bowing when laid upon a flat surface prior to loading, and to provide resiliency for facilitating the base assembly assuming a substantially flat configuration when a predetermined payload is placed upon the base assembly; (b) an X-ray member; (c) apparatus for detachably mounting a table member to the base assembly to hold the table member at a location above the base; (d) an X-ray source; (e) means for sensing X-rays to form an image; (f) means for mounting the X-ray source ...
The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-rayimaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)
We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.
X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove ...
X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the ...
PurposeAuto-propagation of anatomical region-of-interests (ROIs) from the planning CT to daily CT is an essential step in image-guided adaptive radiotherapy. The...Full Text Available
The meeting was arranged into the following sessions: introductory; advanced ceramics and ceramic composites; ceramic and metal matrix composites; electronic materials and devices; acoustoelasticity, stress, and texture; composites-porosity, strength, and UT propagation; process modeling and monitoring; thermal wave physics; material properties, composites, surfaces, and interfaces; acoustic emission; ferromagnetic materials; new sensors; NDE reliability assessment; elastic wave scattering and propagation; image analysis, data storage, and signal processing; UT transducers; weldments and bonded materials; eddy current models; unified life cycle engineering; xrays, CT, and NMR; eddy current probes and instruments; acoustic microscopy imaging, and reconstruction; signal processing, measurement techniques, and systems; NDE applications of artificial intelligence; crack behavior ...
Context: The colliding-wind binary Eta Car exhibits soft X-ray thermal emission that varies strongly around periastron, and non-thermal emission seen in hard X-rays and gamma-rays. Aims: To definitively identify Eta Car as the source of the hard X-ray emission, to examine how changes in the 2-10 keV band influence changes in the hard X-ray band, and to understand more clearly the mechanisms producing the non-thermal emission using new INTEGRAL observations obtained close to periastron. Methods: A Chandra observation encompassing the ISGRI error circle was analysed, and all other soft X-ray sources (including the outer shell of Eta Car itself) were discarded as likely counter-parts. New hard X-rayimages of Eta Car were studied close to periastron, and compared to previous observations far from periastron. Results: The INTEGRAL component, ...
Recent X-ray and radio observations have identified a transient low-mass X-ray binary (LMXB) located only 0.1 pc in projection from the Galactic center, CXOGC J174540.0-290031. In this paper, we report the detailed analysis of X-ray and infrared observations of the transient and its surroundings. Chandra bservations detect the source at a flux of F_X = 2e-12 erg cm^-2 s^-1 (2-8 keV). After accounting for absorption both in the interstellar medium and in material local to the source, the implied luminosity of the source is only L_X = 4e34 erg/s (2-8 keV; D=8 kpc). However, the diffuse X-ray emission near the source also brightened by a factor of 2. The enhanced diffuse X-ray emission lies on top of a known ridge of dust and ionized gas that is visible infrared images. We interpret the X-ray emission as scattered flux from the outburst, and ...
Positron emission tomography (PET) and X-ray computed tomography (CT) performed with PET/CT cameras allow us to obtain concurrently information on the presence and degree of alterations of myocardial perfusion and metabolism and on coronary arteries calcification. Furthermore, by gated myocardial perfusion studies, PET may provide crucial information on regional coronary blood flow reserve and endothelial dysfunction. A number of recent papers provide some insight on the potential of PET/CT in cardiology and in the assessment of various cardiovascular diseases including various types of vasculitis and metabolic diseases.
The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-rayimaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase ...
To treat or prevent some of the 795,000 annual strokes in the U.S., self-expanding endo-vascular stents deployed under fluoroscopic image guidance are often used. Neuro-interventionalists need...Full Text Available
Considering the hardware characteristics of the laser-induced plasma X-ray source and the limitations of the conventional cone-beam reconstruction algorithm, a general cone-beam reconstruction algorithm has been developed at our laboratory, in which the motion locus of the X-ray source is an arbitrary curve corresponding to at least a 2{pi} continuous horizontal angular displacement in the coordinate system of the specimen. The preliminary simulation shows that the general cone-beam reconstruction algorithm consistently results in visually satisfactory images.
Considering the hardware characteristics of the laser-induced plasma X-ray source and the limitations of the conventional cone-beam reconstruction algorithm, a general cone-beam reconstruction algorithm has been developed at our laboratory, in which the motion locus of the X-ray source is an arbitrary curve corresponding to at least a 2{pi} continuous horizontal angular displacement in the coordinate system of the specimen. The preliminary simulation shows that the general cone-beam reconstruction algorithm consistently results in visually satisfactory images.
Evaluation of the tolerance limits of X-rayimage density accepted by the radiologist shows that for different kinds of examinations, deviations of more than 50% from optimal density lead to images which cannot be used diagnostically. Within this range diagnostic accuracy shows a distinct maximum and diminishes to the limits by 20%. These figures are related to differences in the intensifying factor of screens, sensitivity of films, sensitometric parameters of film processing as well as the doses employed with automatic exposure control devices, measured in clinical conditions. Maximum permissible tolerance limits of the whole imaging system and of its constituents are discussed using the Gaussian law of error addition. (author).
This manuscript reviews some of the more controversial dose-related issues in cardiac CTimaging. Discussion covers the relative merits of cardiac CT versus MR, advantages and concerns regarding gated versus nongated cardiac CT and advantages and concerns regarding the use of breast shields in girls undergoing cardiac CTimaging.
A 65-year-old woman who was diagnosed as having psoitis by CT findings, which disclosed non-symmetrical dilation of the psoas muscle and gaseous image. Pus from the psoas muscle seen at surgery corresponded to CT findings. Preoperative CT examination was useful in the establishment of diagnosis. (Namekawa, K.).
AIM: To improve the diagnosis of heterotopic pancreas by the use of contrast-enhanced computed tomography (CT) imaging and CT virtual endoscopy (CTVE).METHODS: A total of six patients with heterotopic...Full Text Available
Computed Tomography (CT) of the spine was performed on 17 patients with myeloma in order to assess the role of the technique in recognizing and evaluating the extent of the lesions. Myelomatous lesions followed two patterns at CT: first of all, multiple focal lesions, whose density is either solid, liquid, or fatty; second, an extensive pattern involving the spongiosa of the vertebra, including the posterior arch. CT detected more lesions than conventional radiology; furthermore, the extent of the lesions was much better demonstrated by CT. CT should thus be performed: a) in case of pain and/or neurological findings in negative radiological examinations; b) to evaluate the extent of myelomatous lesions (mainly in the spine); c) in solitary myeloma CT may be performed on different bone segments with clinical symptomatology but normal X-ray ...
The principle and history of free-electron laser (FEL), first evidenced in 1977, the relationship between FEL wavelength and output power, the high-power FEL driven by the superconducting linac, the X-ray FEL by the linac, and the medical use are described. FEL is the vacuum oscillator tube and essentially composed from the high-energy linac, undulator and light-resonator. It utilizes free electrons in the vacuum to generate the beam with wavelength ranging from microwave to gamma ray. The first high-power FEL developed in Japanese Atomic Energy Research Institute (JAERI) is based on the development of superconducting linac for oscillating the highest power beam. In the medical field, applications to excise brain tumors (in US) and to reconstruct experimentally blood vessels in the pig heart (in Gunma University) by lasing and laser coagulator are in progress with examinations to remove intra-vascular cholesterol mass by irradiation of 5.7#mu#m FEL beam. Cancer ...
The treatment of bony, osteochondral, and ligamentous injuries of the tibio-talar requires precise preoperative planning by radiological investigation. This is essential to a correct understanding of the underlying pathology and will allow a proper classification of the injury, which is the basis of treatment. Conventional radiography using anteroposterior and lateral X-rays with comparative views of the noninjured side and, if necessary, rotated spot views and tomography are of high value especially in osteochondral fractures of the talus. Intraoperative control images in both planes after osteosynthesis are mandatory. For evaluation of the postoperative course and severity of arthrosis formation, the classification system of Bargon has proved its worth. In addition, tomography of the tibio-talar joint in two planes is useful especially in tibial pilon fractures, some malleolar fractures, and peripheral talar fractures. In talar fracture ...
Energy-filtered X-ray photoemission electron microscopy (EXPEEM) is a microscopy technique which has the potential to provide surface chemical mapping during surface chemical processes on the nanometer scale. We studied the possibilities of EXPEEM using a Wien filter type energy analyzer in the high energy X-ray region above 1000 eV. We have successfully observed the EXPEEM images of Au islands on a Ta sheet using Au 3d_5_/_2 and Ta 3d_5_/_2 photoelectron peaks which were excited by 2380 eV X-rays emitted from an undulator (BL2A) at Photon Factory. Our recent efforts to improve the sensitivity of the Wien filter energy analyzer will also be discussed.
The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-rayimaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.
Multi-kilo-electron-volt x-ray microscopy will be an important laser-produced plasma diagnostic at future megajoule facilities such as the National Ignition Facility (NIF). However, laser energies and plasma characteristics imply that x-ray microscopy will be more challenging at NIF than at existing facilities. We use analytical estimates and numerical ray tracing to investigate several instrumentation options in detail, and we conclude that near-normal-incidence single spherical or toroidal crystals may offer the best general solution for high-energy x-ray microscopy at NIF and similar large facilities. Apertured Kirkpatrick{endash}Baez microscopes using multilayer mirrors may also be good options, particularly for applications requiring one-dimensional imaging over narrow fields of view. {copyright} 1998 Optical Society of America
Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point ...
In Spiral CT, the pitch is the ratio of the distance to tabletop travels per 360 degrees rotation to nominal slice width, expressed in mm. Performing Spiral CT examination with pitch 2 allows to reduce examination time, exposure and contrast dose, and X-ray tube overload. The authors investigated the yield of pitch 2 in lung parenchyma studies, particular relative to diagnostic image quality. [Italian] Nella Tomografia Computerizzata (TC) spirale il rapporto tra la distanza percorsa dal lettino portapaziente in una rotazione e lo spessore nominale dello strato, entrambi espressi in millimetri, si definische pitch. Se i due valori del rapporto coincidono si avra' pitch uguale a 1, mentre raddoppiando la distanza percorsa dal lettino portapaziente, per il medesimo spessore nominale, conseguentemente raddoppia il pitch (pitch 2). Eseguire gli esami TC spirale utilizzando pitch 2, consente di ...
X-rayimaging using asymmetric Bragg reflection in the hard x-ray regime opens the way to improve the spatial resolution limit below 1 #mu#m by magnifying the image before detection, simultaneously providing a strong phase contrast. A theoretical formalism of the imaging process is established. Based on this algorithm, numerical simulations are performed and demonstrate that both Fresnel propagation and Bragg diffraction contribute to contrast formation. The achievable resolution of this technique is investigated theoretically; the results obtained can be used to improve future experimental setups. Furthermore, the minimum detectable phase gradient is estimated, for comparison with other phase sensitive imaging techniques. Results from biological objects demonstrate that the technique is viable for imaging both in two and three dimensions. ...
Purpose: Small animal micro-CTimaging is being used increasingly in preclinical biomedical research to provide phenotypic descriptions of genomic models. Most of this imaging is coincident...Full Text Available
Objective: To investigate the feasibility of low-dose single-slice helical CT in pulmonary CT scan and evaluate the clinical application. Methods: Thirteen cases were selected out of 132 cases, in which low-dose (50mAs) single-slice helical CT scan of chest was performed. This set of cases included 7 cases of multiple metastatic nodules; 3 of solitary pulmonary, nodule; and 3 of pulmonary patchy lesions. Regular dose (170mAs) CT scan was also performed on all those patients. The regular dose and low dose CT scan were compared on sensitivity of detecting the lesions; the performance in demonstrating the details of the abnormalities; and the capability of revealing the segmental bronchi as well. Results: The same number and size of the pulmonary nodules were revealed with scan modalities loaded with different doses. No significant difference in demonstrating the details of the nodules ...
Background and AimsXylem vessels containing gases (embolized) must be refilled with water if they are to resume transport of water through the plant, so refilling is of great importance...Full Text Available
An iterative phase retrieval algorithm was previously investigated for in-line x-ray phase imaging. Through detailed theoretical analysis and computer simulations, we now discuss the limitations, robustness, and efficiency of the algorithm. The iterative algorithm was proved robust against imaging noise but sensitive to the variations of several system parameters. It is also efficient in terms of calculation time. It was shown that the algorithm can be applied to phase retrieval based on one phase-contrast image and one attenuation image, or two phase-contrast images; in both cases, the two images can be obtained either by one detector in two exposures, or by two detectors in only one exposure as in the dual-detector scheme.
The Micro-X instrument is a NASA funded, rocket borne X-rayimaging spectrometer planned for launch in January 2011. An array of Transition Edge Sensors (TESs) will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. This will be a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat sink, and will be read out by a SQUID time division multiplexer. X-rays will be focused onto the TES array of 128 pixels on a 600 micron pitch by a conically approximated Wolter optic with an effective area of 200 cm2. The spectrometer will have a field of view of 11.8 arcmin. We describe the design and development progress of the instrument.
We present a Hubble Space Telescope image of the FRII radio galaxy 3C 401, obtained at 1.6 microns with the NICMOS camera in which we identify the infrared counterpart of the brightest region of the radio jet. The jet has a complex radio structure and brightens where bending occurs, most likely as a result of relativistic beaming. We analyze archival data in the radio, optical and X-ray bands and we derive its spectral energy distribution. Differently from all of the previously known optical extragalactic jets, the jet in 3C401 is not detected in the X-rays even in a long 48ksec X-ray Chandra exposure and the infrared emission dominates the overall SED. We propose that the dominant radiation mechanism of this jet is synchrotron. The low X-ray emission is then caused by two different effects: i) the lack of any strong external photon field and ii) the shape of the electron ...
A curved crystal X-ray spectrographs of reflection type spherical geometry was required based on the Johann scheme. Due to their high efficiency and resolution, X-ray spectrographs of focusing spectrograph spatial resolution are suitable for detecting weak X-ray spectra in spectrometers for laser fusion research. Spherically bent mica crystal with a radius of curvature of 380 mm was used in the spectrometer. The Bragg angle of the crystal analyzer was 51 degree. The image plate was employed to obtain high spatial resolution and a narrow spectral band width, with an effective area of 30 mm x 80 mm. The designed optical path of the X-ray spectrometer beam was 980 mm long from the source to the crystal and the detector. The first experiment was carried out at the 20 J energy laser facility of Research Center of Laser Fusion, China Academy of Engineering Physics. ...
Low kVp settings provide high conspicuity of contrast materials at CT but may result in high image noise, particularly in larger patients. Material decomposition at dual energy CT can differentiate...Full Text Available
It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.
Correct ortopedic therapy for traumas of the cervical rachis requires perfect knowledge of the spatial balance of the fracture focus. The authors belive Computed Tomography (CT) to be the most suitable, and often indispensable, method for this purpose. Twenty-four patients were examined for traumatic pathology of the cervical rachis. In 7 cases with clinically minor traumas, the negative outcome of the traditional traumas, the negative outcome of the traditional exam was considered reliable and sufficient for therapeutic purposes. The extant 17 patients were examined also by means of CT, either to better dermine the characteristics of skeletal lesions already ascertained with traditional techniques or to asses the presence of clinically-suspected osteo-articular lesions, even with negative conventional X-rays. For 9 of these patients orthopedic treatment was considered sufficient, whereas 8 patients underwent surgery and ...
Particularly high coherence of the x-ray beam is associated, on the ID19 beamline at ESRF, with the small angular size of the source as seen from a point of the sample (0.1-1 #mu#rad). This feature makes the imaging of phase objects extremely simple, by using a 'propagation' technique. The physical principle involved is Fresnel diffraction. Phase imaging is being simultaneously developed as a technique and used as a tool to investigate light natural or artificial materials introducing phase variations across the transmitted x-ray beam. They include polymers, wood, crystals, alloys, composites or ceramics, exhibiting inclusions, holes, cracks, ... . 'Tomographic' three-dimensional reconstruction can be performed with a filtered back-projection algorithm either on the images processed as in attenuation tomography, or on the phase maps retrieved from the images ...
The principle of radiodiagnosis consists in the fact the X-ray beam is attenuated at different degrees by distinct tissues. For this reason, the anatomical structures have distinct radiological opacities, that produce the radiographic image. The progresses in radiology are related to the development if new radiographic image formation systems that enable an amplification in the quality, with low dose and/or risk to the patient. The objective of this work is the sensitometric valuation of a screen-film combination, that is still the most used, for the standardization, of radiographic images. Thinking about this, were constructed homogeneous phantoms of the chest, skull and pelvis, for the calibration of X-ray beams, with the purpose of obtaining radiographic images of good quality, basing in the routine of a radiodiagnosis service and in the scientific knowledge. ...
The staging of patients with multiple myeloma demands sensitive imaging methods for the assessment of the skeletal system. MRI allows for direct visualization of the bone marrow which exhibits five different infiltration patterns in multiple myeloma: 1. normal appearance of the bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. ''salt and pepper'' pattern with inhomogeneous bone marrow signals due to multiple fat islands. The combination of T1w-SE and STIR sequences is best suited for detecting all infiltration patterns and for the differential diagnoses e. g. hemangiomas. With parallel imaging in MRI, acquisition times can be markedly reduced and whole-body screening of the bone marrow can be achieved within 30 min. MRI is superior to radiography for the detection of focal as well as diffuse infiltration. Multidetector computed tomography ...
An analyzer-based X-ray phase-contrast imaging (ABI) setup has been mounted at the Brazilian Synchrotron Light Laboratory (LNLS) for multiple imaging radiography (MIR) purposes. The algorithm employed for treating the MIR data collected at LNLS is described, and its reliability in extracting the distinct types of contrast that can be obtained with MIR is demonstrated by analyzing a test sample (thin polyamide wire). As a practical application, the possibility of studying ophthalmic tissues, corneal sequestra in this case, via MIR is investigated.
During their life, intervertebral discs undergo degenerative changes which need not necessarily become lesions. Conventional X-rays do not provide information on the condition of the intervertebral discs, so MRT or CT are recommended as primary techniques as they are non-invasive. Invasive methods like myelography and especially discography should not be used unless a case is highly problematic. In infants with pains in the back, MRT should be carried out as early as possible as there is nearly always an organic cause. (orig.)
Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography ...
The X-ray storage phosphor CsBr:Eu2+ in form of needle image plates is believed to be a promising alternative to the granular BaFBr:Eu2+ with regard to PSL yield and spatial resolution. Unfortunately, CsBr:Eu2+ exhibits poor radiation hardness, which is caused by a migration of europium ions initiated by naturally existing defect centers like (Eu2+-VCs)-centers and X-ray generated MEu-centers. It will be shown that the formation of (Eu2+-O2?)-dipoles at the expense of (Eu2+-VCs)-dipoles, incorporated by thermal annealing in O2-containing and humid atmosphere, does not improve the radiation stability. There is, however, a strong improvement in the radiation hardness by codoping of CsBr:Eu2+ with lithium ions, which is accompanied by a complete suppression of the previously observed MEu-cent...
The results of experiments received on the plasma focus (PF) device with energy stored equal 4 kJ are represented. Photos of the current plasma sheath (CPS), pre-pinch, sphere-like plasma formations are produced with help of the electron-optical converter contained a gated micro-channel plate (MCP) and the CCD-camera imaging system in the visible region. The redial velocity of the CPS is about 107 cm/s. Neon plasma electron density measured with help of the interferograms in the visible region and the spectra in the soft X-ray region is equals to 3?1018 cm-3. Electron temperature is equal to about 200 eV. Discharge integral photos were obtained with help of the soft X-ray pinhole camera. Pictures with 2 ?s resolution of the plasma luminescence above PF anode region were made by CCD-camera.
The use of nondestructive evaluation (NDE) methods is proposed for characterization of transuranic (TRU) waste stored at the Radioactive Waste Management Complex. These NDE methods include real-time x-ray radiography, real-time neutron radiography, x-ray and neutron computed tomography, thermal imaging, container weighing, visual examination, and acoustic measurements. An integrated NDE system is proposed for characterization and certification of TRU waste destined for eventual shipment to the Waste Isolation Pilot Plant in New Mexico. Methods for automating both the classification waste and control of a complete nondestructive evaluation/nondestructive assay system are presented. Feasibility testing of the different NDE methods, including real-time x-ray radiography, and development of automated waste classification techniques are covered as part of a five year effort designed to yield a production ...
A galactose-specific seed lectin was purified from the legume Spatholobus parviflorus and crystallized using the hanging-drop vapour-diffusion technique. Thecrystals belonged to space group P1, with unit-cell parameters a = 60.998, b=60.792, c = 78.179-, = 101.32, = 91.38, = 104.32. X-ray diffraction data were collected under cryoconditions (100-K) to a resolution of 2.04- using a MAR image-plate detector system mounted on a rotating-anode X-ray (Cu-K) generator. Molecular replacement using legume-lectin coordinates as a search model gave a tetrameric structure.
In situ X-Ray microtomography offers new opportunities for analysing sintering mechanisms since it allows 3D observation of the microstructural evolution of the powder all along a sintering cycle. With synchrotron radiation at ESRF, a 3D image with a resolution of 2 {mu}m can be obtained in about one minute. In addition to the visual examination of the images, relevant microstructural parameters can be measured through quantitative image analysis using recently developed tools. In this paper the results obtained with two materials, loose copper powder and compacted steel powder, are resumed. For copper powder, the dispersion of local parameters such as particle co-ordination number and porosity is investigated. Concerning steel compacts, data about pore morphology evolution and on local strains provides clues for understanding the anisotropic shrinkage of such compacts. (authors)
Advances in laboratory animal imaging have provided new resources for noninvasive biomedical research. Among these technologies is microcomputed tomography (microCT) which is widely used to obtain high...Full Text Available
This paper presents a new deformable model using both population and patient-specific statistics to segment the prostate from CTimages. There are two novelties in the proposed method. First,...Full Text Available
Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available
Coded imaging techniques using thick, micro-Fresnel zone plates as coded apertures have been used to imagex-ray emissions (2-20 keV) and 3.5 MeV Alpha particle emissions from laser driven micro-implosions. Image resolution in these experiments was 3-8 ..mu..m. Extension of this coded imaging capability to higher energy x-rays (approx. 100 keV) and more penetrating charged particles (e.g. approx. 15 MeV protons) requires the fabrication of very thick (50-200 ..mu..m), high aspect ratio (10:1), gold Fresnel zone plates with narrow linewidths (5-25 ..mu..m) for use as coded aperatures. A reactive ion etch technique in oxygen has been used to produce thick zone plate patterns in polymer films. The polymer patterns serve as electroplating molds for the subsequent fabrication of the free-standing gold zone plate structures.
Coded imaging techniques using thick, micro-Fresnel zone plates as coded apertures have been used to imagex-ray emission (2--20 keV) and 3.5 MeV Alpha particle emissions from laser driven micro-implosions. Image resolution in these experiments was 3--8 ..mu..m. Extension of this coded imaging capability to higher energy xrays (approx.100 KeV) and more penetrating charged particles (e.g., approx.15 MeV protons) requires the fabrication of very thick (50--200 ..mu..m), high aspect ratio (10:1), gold Fresnel zone plates with narrow linewidths (5--25 ..mu..m) for use as coded apertures. A reactive ion etch technique in oxygen has been used to produce thick zone plate patterns in polymer films. The polymer patterns serve as electroplating molds for the subsequent fabrication of the free-standing gold zone plate structures.
Secondary ion mass spectrometry (SIMS), secondary electron microscopy (SEM) and X-ray analysis have been applied to the measurement of U-bearing particles with the intent of gleaning information concerning their history and/or origin. The lead isotopic abundances are definitive indicators that U-bearing particles have come from an ore-body, even if they have undergone chemical processing. SEM images and X-ray analysis can add further information to the study that may allude to the extent of chemical processing. The presence of 'common' lead that does not exhibit a radiogenic signature is clear evidence of anthropogenic origin. (author)
In dual-energy projection radiography with double exposures, rapid energy switching is mandatory to eliminate motion artifacts, but it is costly for use in a clinical environment. We developed a system with practical exposure intervals at reasonable cost by modifying a condenser-type X-ray generator. A commercially available system for digital radiography (Fuji Computed Radiography, FCR) was used to subtract images. This report dealt with technical factors to obtain adequate kV and mAs settings in this technique.
In dual-energy projection radiography with double exposures, rapid energy switching is mandatory to eliminate motion artifacts, but it is costly for use in a clinical environment. We developed a system with practical exposure intervals at reasonable cost by modifying a condenser-type X-ray generator. A commercially available system for digital radiography (Fuji Computed Radiography, FCR) was used to subtract images. This report dealt with technical factors to obtain adequate kV and mAs settings in this technique. (author).
This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is ...
Radiation damage is considered to be the major problem that still prevents imaging an individual biological molecule for structural analysis. So far, all known mapping techniques using sufficient short wave-length radiation, be it X-rays or high energy electrons, circumvent this problem by averaging over many molecules. Averaging, however, leaves conformational details uncovered. Even the anticipated use of ultra-short but extremely bright X-ray bursts of a Free Electron Laser shall afford averaging over 10^6 molecules to arrive at atomic resolution. Here we present direct experimental evidence for non-destructive imaging of individual DNA molecules. In fact, we show that DNA withstands coherent low energy electron radiation with deBroglie wavelength in the Angstrom regime despite a vast dose of 10^8 electrons/nm^2 accumulated over more than one hour.
Positron-emission tomography (PET) and PET/CT (computed tomography) are becoming increasingly important for diagnosis and treatment of cancer. Clinically relevant changes can sometimes be seen on PET that are not seen on other imaging modalities. However, PET is not suitable for guiding biopsy as the images are not obtained in real-time. Therefore, our research group has begun developing a concept for PET/CT-guided interventional procedures. This paper presents the rationale for this concept, outlines our research plan, and includes an initial study to evaluate the relative sensitivity of CT and PET/CT in detecting suspicious lesions. (orig.)
Absorption spectra of the CT bands of I_2 complexes with Et_2O, Et_2S, and Et_2Se in heptane have been measured up to 4400 bar at 25"0C. The equilibrium constants and the volume changes accompanying complex formation, and the molar extinction coefficients and absorption maxima have been estimated. The volume changes were comparable with those estimated by the visible I_2 bands and by the X-ray data of the I_2 complexes in the crystalline state. In the CT bands of Et_2S-I_2 and Et_2Se-I_2 complexes inversion of shift from red to blue has been observed with increasing pressure though the CT band of Et_2O-I_2 complex shifted only through red. This inversion appears to be characteristic of the strong CT complex. Enhancement of the molar extinction coefficient of the CT band has been found with increasing pressure suggesting enhancement of the CT ...
When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated through contrast ...
When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated through contrast ...
Despite its great usefulness in the performance of the recording procedures prescribed by the X-Ray Ordinance the dose-area product is much less frequently measured for X-ray exposures than during fluorscopic examinations. The great multitude of measuring units, mainly on account of different scales of the measuring equipments themselves, is a cause of uncertainty in clinical routine and should be eliminated as far as the circumstances would permit. As the determination of the organ dose is relevant only in very few cases and does not necessarily require previous measurements of the dose-area product, these are of limited practical value in the assessment of individual radiation exposures during radiographic examinations. The measurements may, however, be very helpful in determinations of the radiation dose to the total population, if the future retrievability of the values obtained is ensured. In addition to some measuring values showing past ...
We report results from a 50 ks XMM-Newton observation of the dust-reddened broad-line quasar FTM 0830+3759 (z=0.413) selected from the FIRST/2MASS Red Quasar survey. For this AGN, a very short 9 ks Chandra exposure had suggested a feature-rich X-ray spectrum and HST images revealed a very disturbed host galaxy morphology. Contrary to classical, optically-selected quasars, the X-ray properties of red (i.e. with J-Ks> 1.7 and R-Ks> 4) broad line quasars are still quite unexplored, although there is a growing consensus that, due to moderate obscuration, these objects can offer a unique view of spectral components typically swamped by the AGN light in normal, blue quasars. The XMM-Newton observation discussed here has definitely confirmed the complexity of the X-ray spectrum revealing the presence of a cold (or mildly-ionized) absorber with Nh ~10^{22} cm^-2 along the line of sight to the nucleus and ...
Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy electron beam therapy. (author)
Which imaging modalities are appropriate for the Differential diagnosis of Rheumatic diseases. MRI has far most the highest sensitivity and is unequaled in its brilliant presentation of Anatomy and Pathology. But it is sometimes forgotten, that this is at least in part the result of carefully selected sequences, dedicated to the expected result. In a method totally independent of any result, this should not be the case. In contrary this method should be highly standardised and regardless what will be the findings. This is true for Plain X-ray. It will be shown, that already the outer silhouette of the soft parts with different features of swelling, and differences in density and even more - defects or appositions of the bony silhouette in the majority of cases at least will allow to classify the patient for a group of diseases and in many cases will lead to a definite diagnosis. Differential diagnoses like Rheumatoid Arthritis versus Psoriatic ...
Following the conventional X-ray diagnosis of the skull and upper cervical spine, CT proved to be the primary diagnostic method after a skull and brain injury: For all 4 cases we succeeded in detecting the occipital condyle fracture and in determing its size and location by reconstructions (coronal, sagittal, 3-D). In the case of complex occompanying injuries like soft tissue hematomas (cerebral, in the spinal cord, and the soft tissue of the neck) or for the detection of brain stem contusion, MRT had significant advantages. MRT can offer a higher image quality in soft tissue, especially in the spinal cord and the brain. (orig.) [Deutsch] Im Anschluss an die konventionelle Roentgendiagnostik des Schaedels und der Halswirbelsaeule, erwies sich die Computertomographie als primaer einzusetzendes diagnostisches Verfahren, nach erlittenem Schaedel-Hirn-Trauma. In allen Faellen gelang der exakte Frakturnachweis an den ...
The main goal of local drug delivery is to increase the concentration of a specific therapeutic agent in a target tissue with minimal nontarget distribution. Compared to systemic therapy, local drug delivery provides a high level of therapeutic efficacy with minimal systemic effects. The current primary imaging modality for drug delivery has been x-ray angiography, but it has major limitations including anatomical ambiguity and inability to visualize the targeted tissues. Due to these inherent problems, MR guidance has been explored as an alternative imaging modality for guiding and monitoring of drug therapy. Recently, interventional MR (XMR) systems have been implemented that have both dual x-ray and MRI capabilities in a single suite and allow for real-time interventional procedures to ...
The development of a replacement to the conventional film based X-rayimaging technique is required for many reasons. One possible route for this is the use of a large area film of a suitable semiconductor overlaid on an amorphous silicon readout array. A suitable semiconductor exists in cadmium telluride and its tertiary alloy cadmium zinc telluride. In this thesis the spectroscopic characteristics of commercially available CZT X- and gamma-radiation detectors are established. The electronic, optical, electro-optic, structural and compositional properties of these detectors are then investigated. The attained data is used to infer a greater understanding for the carrier transport in a CZT radiation detector following the interaction of a high energy photon. Following this a method used to fabricate large area films of CdTe on a commercial scale is described. This is cathodic electrodeposition from an aqueous electrolyte. The theory and ...
Purpose: This study presents a dosimetric optimization effort aiming to compare intensity-modulated (IM) X-rays and IM protons in 4 different orbital and paraorbital tumors. These are most challenging targets for standard radiotherapy due to their close relationship with the eyes and related structures. Methods and Materials: A primary orbital lymphoma, an optic nerve meningioma, a sphenoidal ridge meningioma protruding into the orbit, and a pediatric parameningeal paraorbital rhabdomyosarcoma were selected for the purpose of this study. Planning target volumes (PTVs) and organs at risk (OAR) were defined in each patient CT data set for each tumor site. IM X-ray and IM proton three-dimensional treatment plans were implemented. The following total tumor doses were prescribed: 30 Gy for the orbital lymphoma, 54 Gy for both meningiomas, and 50.4 Gy for the rhabdomyosarcoma case. Dose-volume histograms (DVHs) were obtained for ...
Available in abstract form only. Full text of publication follows: The application spectrum of X-ray and Gamma radiation is increasing exponentially in the area of diagnostic, nuclear medicine, food preservation, nuclear power plants and strategic utilities. To prevent the harmful effects of these radiations, shielding materials based on lead metal and its compounds are being used historically, which are toxic in nature. To protect environment it has become necessary to develop non-toxic lead free shielding materials. The use of titanium metal and its compounds as synthetic rock i.e. SYNROC are reported to be very effective non-toxic shielding materials for various applications. Red mud waste generated in aluminum producing industries possesses a unique mineralogical compositions containing fairly high quantity of titanium oxide and iron oxide useful for making non toxic shielding compositions and therefore red mud has been utilized for the first time in the world ...
We used computerized tomography (CT) in the study of eight patients with macronodular splenic tuberculosis prior to the microbiological diagnosis. These patients underwent additional CT controls during and after tuberculostatic therapy. All the patients studed presented the acquired immunodeficiency syndrome (AIDS). Splenomegaly and numerosous round, hypodense lesions that showed no contrast uptake were found in all the subjects. Only three patients presented evidence of tuberculosis in plain radiography and/or chest X-ray. Two patients presented abdominal lymph nodes. None of them showed evidence of hepatic lesions or ascites. follow-up CT scans revealed a progressive reduction of the lesions, which eventually disappeared completely, and splenomegaly was considerably reduced. Anthough it is uncommon, we should suspect splenic involvement in tuberculosis if the clinical and radiological contexts are ...
To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that (1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; (2) approximately equal detection rates were obtained ...
To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that 1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; 2) approximately equal detection rates were obtained ...
Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. One key component of 4D radiotherapy planning...Full Text Available
Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available
Heterogeneous gasless reactive systems, including high-energy density metal-nonmetal compositions, have seen increasing study due to their various applications. However, owing to their high reaction temperature, short reaction time, and small scale of heterogeneity, investigation of their reaction mechanisms and kinetics is very difficult. In this study, microstructural changes and the kinetics of product layer growth in the W-Si system was investigated using a high-speed x-ray phase-contrast imaging technique. Using the Advanced Photon Source of Argonne National Laboratory, this method allowed direct imaging of irreversible reactions in the W-Si reactive system at frame rates up to 36 000 frames per second with 4 {mu}s exposure and spatial resolution of 10 {mu}m. Details of the Si melt and reactions between W and Si, that are unable to be viewed with visible-light imaging, were revealed. These include ...
Heterogeneous gasless reactive systems, including high-energy density metal-nonmetal compositions, have seen increasing study due to their various applications. However, owing to their high reaction temperature, short reaction time, and small scale of heterogeneity, investigation of their reaction mechanisms and kinetics is very difficult. In this study, microstructural changes and the kinetics of product layer growth in the W-Si system was investigated using a high-speed x-ray phase-contrast imaging technique. Using the Advanced Photon Source of Argonne National Laboratory, this method allowed direct imaging of irreversible reactions in the W-Si reactive system at frame rates up to 36 000 frames per second with 4 #mu#s exposure and spatial resolution of 10 #mu#m. Details of the Si melt and reactions between W and Si, that are unable to be viewed with visible-light imaging, were revealed. These include ...
An interfacial shear stress equation in the dispersed-annular two-phase flow regime has been developed, which is based on a three-fluid model consisting of a liquid film on a rod, vapor and entrained liquid associated with a vapor flow. It is an extension of J.G.M. Andersen's procedure that provides a two-fluid interfacial shear stress equation using the drift flux parameters C{sub 0} and V{sub gj}. This interfacial shear stress equation can take into account a phase and velocity distribution through an equivalence between the drift flux parameters and the interfacial shear stress. Using the three-fluid subchannel analysis code TEMPO with the three-fluid interfacial shear stress model the capability of a three-fluid calculation using the drift flux parameters C{sub 0} and V{sub gj} that reproduce a measured void fraction is demonstrated. A comparison was made with advanced X-ray computed tomography (CT) void fraction data within a 4x4 ...
Objective. For the multislice CT (MSCT) systems with a larger number of detector rows, it is essential to employ dose-reduction techniques. As...Full Text Available
We studied 129 AIDS patients with suspected or proved intracranial manifestations of the disease. The purpose of this study was to compare the diagnostic sensitivity of unenhanced and contrast enhanced CT and unenhanced T{sub 2}-weighted MR. Thus, in 20% of our patients MR but not CT was diagnostic. In another 20% MR provided additional diagnostic information. In conclusion, MR is recommended as the imaging modality of choice in AIDS patients with non-conclusive cranial CT. (orig./GDG).
A study on brain CT was made in 120 patients of human cysticercosis, which is a rare disease in Japan and clinical symptoms and laboratory data for the diagnosis were also discussed. From the point of therapeutic view, we proposed a new differentiation on brain CT of human cysticercosis, which is divided into two groups according to the alve or dead parasite. Furthermore, we proposed a new type named multiple large and small cysts type on brain CT. The idea of diagnostic standard was made integrating brain CTimage, clinical symptoms and labolatory data. (author).
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable ...
An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. ...
Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the cervicothoracic region, where it is usually difficult ...
From the frequency of diagnostic radiologic examinations and their radiation dose delivered to the population the risk of cancer induction and genetic damage is calculated on the basis of the risk factors given by the ICRP. Thus 0.38 % and 3 % of the total mortality for cancer and leukemia, resp., can be attributed to X-ray diagnostics. Chest examinations alone result in 0.07-0.7 damages per 100,000 persons depending on the imaging technique applied. (author).
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable ...
Tridimensional localization of bone and soft tissue injuries in complex facial trauma is fundamental for treatment. The face can be conceptualized as 3 groups of interconnected osseous struts that are oriented in the horizontal, sagittal and coronal planes. Each group of struts is closely related to specific soft tissue structures that are susceptible to injury. Any single CT section in the coronal plane or in the axial plane contains parts of one or more these struts. Facial CT in biplane were performed in 32 patients of facial trauma. The most common site of facial fractures is found in middle part of horizontal struts, geometrically in anteromedial portion of the inferior orbital fissure of the face. The most common soft tissue injury combined with facial fracture is hematoma and/or herniated orbital contents into the maxillary sinus. The serious combined soft tissue injuries were ocular rupture, retroorbital hematoma and optic nerve injury ...
While there have been many experimental and calculational investigations on absorbed dose distribution in the patient resulting from conventional X-ray procedures, such data for computerized tomography (CT) are still sparse. As this diagnostic procedure has shown a rapid increase in application during recent years, we have determined absorbed dose to body organs in a human phantom resulting from CT examinations. The exposure model consists of the heterogeneous MIRD-5 phantom and a suitable Monte-Carlo method to calculate absorbed dose to organs of interest. The exposure conditions are specified according to the exposure specifications of a CT-scanner currently in use. The calculations cover the range of body tissues of interest in terms of organ absorbed doses as well as a risk weighted absorbed dose. A detailed example showing the calculation of red bone marrow dose is given and a somatic effective ...
... The constancy of the X-ray intensity ratio for each element in Table 8 as the X-ray tube settings were changed shows the excellent compensating ...
We compare experimental measurements of inhomogeneous plastic deformation in a Ni bicrystal with crystal-plasticity simulations. Polychromatic X-ray microdiffraction, orientation imaging microscopy and scanning electron microscopy, were used to characterize the geometrically necessary dislocation distribution of the bicrystal after uniaxial tensile deformation. Changes in the local crystallographic orientations within the sample reflect its plastic response during the tensile test. Elastic strain in both grains increases near the grain boundary. Finite element simulations were used to understand the influence of initial grain orientation and structural inhomogeneities on the geometrically-necessary dislocations arrangement and distribution and to understand the underlying materials physics.
We propose an X-ray mission called Xenia to search for decaying superweakly interacting Dark Matter particles (super-WIMP) with a mass in the keV range. The mission and its observation plan are capable of providing a major break through in our understanding of the nature of Dark Matter (DM). It will confirm, or reject, predictions of a number of particle physics models by increasing the sensitivity of the search for decaying DM by about two orders of magnitude through a wide-field imagingX-ray spectrometer in combination with a dedicated observation program. The proposed mission will provide unique limits on the mixing angle and mass of neutral leptons, right handed partners of neutrinos, which are important Dark Matter candidates. The existence of these particles is strongly motivated by observed neutrino flavor oscillations and the problem of baryon asymmetry of the Universe. In super-WIMP models, the details of the ...
We present a fully automated method for three-dimensional (3D) elemental analysis demonstrated using a ceramic sample of chemistry (Ca)MgTiO_x. The specimen is serially sectioned by a focused ion beam (FIB) microscope, and energy-dispersive X-ray spectrometry (EDXS) is used for elemental analysis of each cross-section created. A 3D elemental model is reconstructed from the stack of two-dimensional (2D) data. This work concentrates on issues arising from process automation, the large sample volume of approximately 17x17x10 #mu#m"3, and the insulating nature of the specimen. A new routine for post-acquisition data correction of different drift effects is demonstrated. Furthermore, it is shown that EDXS data may be erroneous for specimens containing voids, and that back-scattered electron images have to be used to correct for these errors.
Fuji Computed Radiography (FCR) is a new system of digital radiography that is based on the latest computer technologies. We applied this FCR system to the X-ray diagnosis of the laryngeal disease. Twenty patients with various laryngeal diseases were evaluated by both FCR frontal tomography and conventional screen-film frontal tomography under the same exposure condition. Both tomograms were then compared on the subject of the clarity of delineation of laryngeal structures. As the result, FCR tomograms revealed the feature of the laryngeal lumen and cartilages more clearly than conventional tomograms. In addition, energy subtraction method, which is one of FCR image processing systems, was presented as a new technical procedure to extinguish cervical spine shadows in plain anteroposterior laryngeal X-photograph. We stress that FCR system is the suitable procedure for X-ray analysis of laryngeal diseases, especially in the ...
Objectives Clinical PET/MR requires the use of patient positioning aids to immobilize and support patients for the duration of the combined examination. Ancillary immobilization devices contribute to overall attenuation of the PET signal, but are not detected with conventional MR sequences and, hence, are ignored in standard MR-based attenuation correction (MR-AC). We report on the quantitative effect of not accounting for the attenuation of patient positioning aids in combined PET/MR imaging. Methods We used phantom and patient data acquired with positioning aids on a PET/CT scanner (Biograph 16, HI-REZ) to mimic PET/MR imaging conditions. Reference CT-based attenuation maps were generated from measured (original) CT transmission images (origCT-AC). We also created MR-like attenuation map...
To assess the malignant potential of small({<=}15mm) portal defects seen on CT arterial portography, the findings of CT hepatic arteriography and lipiodol CT were reviewed. In 91 patients who underwent both CTAP and CTHA, small portal defects were reviewed for frequency, multiplicity and location. We prospectively evauluated changes in the size and enhancement pattern of malignant lesions on follow up CT according to density on CTHA, location, lipiodol deposits on lipiodol CT, and multiplicity. Among the 91 patients, 102 small defects were defected in 42 patients(46%). Small portal defects were benign, malignant, and of undetermined malignant potential in 77%, 20% and 3% of cases, respectively. Small portal defects that were hyperattenuated on CTHA, and lipiodol deposits on lipiodol CT, were malignant in 42% and 70% of cases, respectively. Location and ...
The authors present a comparison between the diagnostic accuracy of Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) in the articular pathologies of the knee. CT and MRI were performed in 30 patients who subsequently underwent surgery. CT and MRI results were compared on three bases: technique, definition of normal anatomy, and diagnostic accuracy. CT allowed a standardization of the technique, while MRI was superior in defining normal anatomy - especially in the study of capsulo-ligamentous structures. In all cases the use of both CT and MRI allowed a correct diagnosis, showing the site, extent and gravity of the lesion. CT proved to be superior to MRI in 4 cases, while MRI corrected CT diagnosis in 11 cases; in 15 patients both techniques had the same diagnostic accuracy. Meniscal tears were better ...
The Micro-X instrument is a rocket borne, X-rayimaging spectrometer planned for launch in October 2011. An array of 128 Transition Edge Sensors (TESs) on a 600 micron pitch will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. X-rays will be focused onto the TES array by a conically approximated Wolter optic with an effective area of 300 cm^2 giving the instrument a field of view of 11.8 arcmin. This performance will constitute a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat bath, and will be read out by a SQUID time division multiplexer. The first flight of the Micro-X instrument will observe the Puppis A supernova ...
In the Wajima lung cancer screening program conducted under the auspices of Kanazawa University Hospital, Fuji Computed Radiography (FCR) was utilized in a new chest radiography trial. The results of the screening program are that the necessity of repeat examinations due to poor image quality are less common and the method enables detection of small pulmonary nodular shadows which are possibly candidates for surgery. Oblique chest X-ray with FCR is remarkably effective for the detection and the identification of small lesions. However, the disadvantage of slow processing and high cost must be fully satisfied if FCR is to become a new imaging modality for mass screening.
In the Wajima lung cancer screening program conducted under the auspices of Kanazawa University Hospital, Fuji Computed Radiography (FCR) was utilized in a new chest radiography trial. The results of the screening program are that the necessity of repeat examinations due to poor image quality are less common and the method enables detection of small pulmonary nodular shadows which are possibly candidates for surgery. Oblique chest X-ray with FCR is remarkably effective for the detection and the identification of small lesions. However, the disadvantage of slow processing and high cost must be fully satisfied if FCR is to become a new imaging modality for mass screening. (author).
As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness.
As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness. (author).
In the past, the need for high quality images, i.e., very sharp and clear images, in mammography have prevented mammography equipment from being digitalized; however, recent advances in detection technology such as development of a high resolution digital X-ray detector have produced improvements in digital mammography. Digital mammography is expected to replace conventional film-screen mammography. We have developed a digital mammography system, named ''SEPIO NUANCE DT'', which is equipped with a direct conversion flat panel detector. The present paper describes the high basic performance and user-friendly functions of the system. (author)
We investigated the efficacy of combined FDG-PET/CTimaging for the diagnosis of small-size uveal melanomas and the feasibility of combining separate, high-resolution (HR) FDG-PET with MRI for its improved localization and detection. Patients, methods: 3 patients with small-size uveal melanomas (0.2-1.5 ml) were imaged on a combined whole-body PET/CT, a HR brain-PET, and a 1.5 T MRI. Static, contrast-enhanced FDG-PET/CTimaging was performed of head and torso with CT contrast enhancement. HR PET imaging was performed in dynamic mode 0-180 min post-injection of FDG. MRI imaging was performed using a high-resolution small-loop-coil placed over the eye in question with T2-3D-TSE and T1-3D-SE with 18 ml Gd-contrast. Patients had their eyes shaded during the scans. Lesion visibility on high-resolution ...
Comparative analysis of diagnostic accuracy (dignity determination) in CT-guided fine-needle biopsy (141 patients), CT (141), ultrasonography (89), angiography (50), and cholegraphy (ERCP, 55), was carried out in suspected space-occupying lesions of the pancreas. With accuracy of 86%, sensitivity of 37% and specificity of 92% fine-needle biopsy was superior to imaging procedures. Additional comparison of the results concerning the patients and Roc curves confirm the statements. For reduction of the number of imaging investigations a diagnostic algorithm is proposed, that starts with diagnostic CT and subsequent fine-needle biopsy controlled by CT. This would result in a more adequate use of angiography and ERCP and in the elimination of ultrasonography. (author).
The concentration of trace elements in brain sections was measured by synchrotron radiation X-ray fluorescence. The relative concentration was calculated by means of the normalization of Compton scattering intensity approximately 22 keV, after the normalization for collecting time of X-ray spectrum and the counting of the ion chamber, and subtracting the contribution of the polycarbonate film for supporting sample. Furthermore, the statistical evaluation of the element distribution in various regions of the brain sections of the 20-day-old rats was tested. For investigating the distribution of elements in the brain of iodine deficient rats, Wistar rats were fed with iodine deficient diet and deionized water (ID group). The rats were fed the same iodine deficient diet, but drank KIO_3 solution as control (CT group). The results showed that the contents of calcium (Ca) in thalamus (TH) and copper (Cu) and iron (Fe) in ...
Purpose: To evaluate micro computed tomography (micro-CT) for the assessment of osteochondritis dissecans in comparison with histology. Material and Methods: Osteochondritis dissecans lesions of 3 patients were evaluated using micro-CT (0.125 mA, 40 keV, 60 m slice thickness, 60 m isotropic resolution, entire sample) and light microscopy (toluidine blue, 3-5 m slice thickness). The methods were compared regarding preparation time, detectability of tissue types and morphologic features of bone and cartilage. Results: Non-destructive micro-CTimaging of the entire sample was faster than histologic preparation of a single slice for light microscopy. Morphologic features of bone and cartilage could be imaged in a comparable way to histology. It was not possible to image cells or different tissue types of bone and cartilage with micro-CT. ...
Purpose: To evaluate micro computed tomography (micro-CT) for the assessment of osteochondritis dissecans in comparison with histology. Material and Methods: Osteochondritis dissecans lesions of 3 patients were evaluated using micro-CT (0.125 mA, 40 keV, 60 m slice thickness, 60 m isotropic resolution, entire sample) and light microscopy (toluidine blue, 3-5 m slice thickness). The methods were compared regarding preparation time, detectability of tissue types and morphologic features of bone and cartilage. Results: Non-destructive micro-CTimaging of the entire sample was faster than histologic preparation of a single slice for light microscopy. Morphologic features of bone and cartilage could be imaged in a comparable way to histology. It was not possible to image cells or different tissue types of bone and cartilage with micro-CT. ...
Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a ...
Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).
339 CT und 95 MRT examinations in 210 partients were evaluated retrospectively to determine the value of CT and MRT for follow-up of head and neck tumors and for diagnosing recurrences. Semi-quantitative evaluation of tumor extent during and after radiotherapy showed advantages for MRT since changes induced by treatment, particularly oedema, produced less contrast loss in the images. CT had a sensitivity of 81% for the recognition of recurrences; this was 92% for MRT. Specificity for CT was 76% and for MRT 86%. Concerning the reliability of individual diagnostic criteria, space occupying lesions were the most valuable in CT diagnosis. For MRT, space occupying lesions and infiltration into neighbouring structures were of equal value. Because of differences in the nature of the signals, MRT proved better than CT in characterising recurrent ...
We compared the characteristics on thin-section CTimages with the histological structure of thirty-four surgically resected peripheral lung lesions 30 mm or less in diameter with a greater than 50% area of GGA on thin-section CT. Pathologically, focal area of GGA corresponded to alveolar replacement growth of tumor or interstitial fibrotic thickening of inflammation. It is considered that determination of the GGA in small peripheral lung lesions on thin-section CT is useful for the diagnosis of early adenocarcinomas. (author)
Paroxysmal nocturnal hemoglobinuria (PNH) is a rare, acquired disease involving multiple hematopoietic cell lines. Characteristics of PNH are intrinsic hemolytic anemia, iron deficiency anemia and venous thrombosis. We report a case of PNH with characterostoc MR and CT findings. The signal intensity of renal cortex was lower than that of medulla on both T1-and T2-weighted MR imaging. On T2 weighted MR images, the liver showed very low signal intensity but the signal intensity of the spleen was normal. On precontrast CT the attenuation of renal cortex was higher than that of renal medulla and the attenuation of liver was higher than that of the spleen. These findings of MR imaging and CT were the result from the deposition of hemosiderin in the cells of proximal convoluted tubules and transfusional hemosiderosis of liver.
We have investigated the nanotexture and crystallographic orientation of aragonite in a coral skeleton using synchrotron-based scanning transmission X-ray microscopy (STXM) and transmission electron microscopy (TEM). Polarization-dependent STXM imaging at 40-nm spatial resolution was used to obtain an orientation map of the c-axis of aragonite on a focused ion beam milled ultrathin section of a Porites coral. This imaging showed that one of the basic units of coral skeletons, referred to as the center of calcification (COC), consists of a cluster of 100-nm aragonite globules crystallographically aligned over several micrometers with a fan-like distribution and with the properties of single crystals at the mesoscale. The remainder of the skeleton consists of aragonite single-crystal fibers in crystallographic continuity with the nanoglobules comprising the COC. Our observation provides information on the nm-scale processes ...
X-ray diffraction enhanced imaging (DEI) is applied to inspect internal structures of weakly absorbing low-Z sample. How to extract phase information from raw images measured in different positions of rocking curve is the key problem of DEI. In this paper, we present an effective extraction method called polynomial curve fitting method, in order to extract accurate information angular in a fast speed. It is com- pared with the existing methods such as multiple-images statistical method and Gaussian curve fitting method. The experiments results on a plastic cylinder and a black ant at the Beijing Synchrotron Radiation Facility prove that the polynomial curve fitting method can obtain most approximate refraction-angle values and its computation speed is 10 times faster than the Gaussian curve fitting method. (authors)
Rotatostereoradiographic (RSRG) images are displayed in an oscillating, rotational manner. While reviewing these rotating images, the radiologist may become psychologically irritated by the rotation. A rapidly rotating display of linear subjects gives one three-dimensional depth information. This three-dimensional sense is lost if the rotation speed is too slow. The authors of this paper determined the slowest possible rotating display speed that allows perception of three-dimensional depth information minimizing psychological irritation. In the RSRG device (Shimadzu ROTATO-360), an x-ray tube coupled with an image intensifier rotates through a 180 degrees arc in 1.8 or 2.25 seconds. Both rotation times could be doubled. The images were displayed at four different speeds, covering the 180 degrees arc in 1.8, 2.25, 3.6, and 4.5 seconds.
To assess the potential of CT in evaluating the histological severity of acute appendicitis in comparison with surgical and pathological findings. The CTimages of 75 patients with surgically proven appendicitis, including 10 cases of catarrhal, 34 of phlegmonous, and 31 of gangrenous appendicitis, were retrospectively analyzed for the following five CT findings: hazy periappendiceal densities, enlarged appendix, increased enhancement of the appendiceal wall, increased enhancement of the periappendiceal intestinal wall, and deficiency of the appendiceal wall. By comparing all the CT findings and the pathological severity of appendicitis (catarrhal, phlegmonous, and gangrenous), the prevalence of the five CT findings was calculated for each pathological category. Abnormal CT findings were noted in only one case of catarrhal appendicitis. ...
A new generation of quasimonochromatic high-flux X-ray sources, based on the X-ray radiation produced through Compton scattering between an electron beam and a laser beam, is under development. One of the possible applications of this source is inline phase contrast mammography, based on the observation of the edge-enhancement effect that can be observed at the border of structures inside the breast in images produced using a partially or totally coherent X-ray beam. In this work we present the results of a set of simulations of inline phase contrast mammography using typical inverse Compton scattering sources parameters. The simulated sample was a tumour-like mass having spherical shape, diameter between 200 {mu}m and 5 mm, placed inside a breast-like matrix, 4 cm thick, and a standard composition of 50% glandular tissue and 50% adipose tissue. We discuss the minimum requirements for mammography using ...
A central problem in diagnostic radiology is to compare a new X-ray picture with a previous picture and from this comparison be able to decide if anatomical changes have occurred in the patient or not. It is of primary interest that these pictures are identical in projection. If not it is difficult to decide with confidence if differences between the pictures are due to anatomical changes or differences in their projection geometry. In this thesis we present a non invasive method that makes it possible to find the relative changes in the projection geometry between the exposure of a previous picture and a new picture. The method presented is based on the projection slice theorem (central section theorem). Instead of an elaborate search for a single new picture a pre-planned set of pictures are exposed from a circular orbit above the patient. By using 3D Fourier transform techniques we are able to synthesize a new X-ray picture from this set of ...
Multi-dimensional modelling of two-phase flow requires accurate constitutive relationships for interfacial parameters such as interfacial heat transfer, void fraction distribution, interfacial area, etc. However, existing diagnostic systems for measurement of two-phase flow parameters have difficulty measuring two or three-dimensional void distributions required for determination of interfacial parameters. In this work, a Real-Time Neutron Radiography (RTNR) system is developed for non-intrusive measurement of two-phase flow parameters in nuclear fuel channels at low thermal neutron fluxes (on the order of 10{sup 6}n/cm{sup 2}-s). This advanced radiation technique has the advantage of measuring two-phase flow in 3 1/2 dimensions (x,{integral}dy,t) where the 1/2 dimension refers to an integrated or averaged space dimension. Pipe flow channels, annulus flow channels, MAPLE-type nuclear fuel flow channels, and CANDU-type nuclear fuel flow channels are investigated. Measurements of flow ...
Multi-dimensional modelling of two-phase flow requires accurate constitutive relationships for interfacial parameters such as interfacial heat transfer, void fraction distribution, interfacial area, etc. However, existing diagnostic systems for measurement of two-phase flow parameters have difficulty measuring two or three-dimensional void distributions required for determination of interfacial parameters. In this work, a Real-Time Neutron Radiography (RTNR) system is developed for non-intrusive measurement of two-phase flow parameters in nuclear fuel channels at low thermal neutron fluxes (on the order of 10"6n/cm"2-s). This advanced radiation technique has the advantage of measuring two-phase flow in 3 1/2 dimensions (x,#integral#dy,t) where the 1/2 dimension refers to an integrated or averaged space dimension. Pipe flow channels, annulus flow channels, MAPLE-type nuclear fuel flow channels, and CANDU-type nuclear fuel flow channels are investigated. Measurements of flow regime, void ...
The introduction of CT scan and, more recently, magnetic resonance imaging, has radically changed the diagnostic approach to tumors developed in the internal auditory canal and cerebellopontine angle. CT scan with intravenous injection visualizes tumors lying in the cerebellopontine angle. Magnetic resonance imaging, especially using gadolinium, is a very accurate means for diagnosing tumors of both the auditory canal and cerebellopontine angle.
The value of CT in respect of preoperative determination of tumour status and of tumour classification was studied using 127 histologically identified ovarial tumours as basis in a blind study via mutual image classification by the two participating institutes. The medium accuracy of diagnosis was 82%, but the results were found to be greatly dependent on tumour histology. Quotas of more than 90% were obtained in case of functional cysts, cystomas, cystadeno-carcinomas and dermoids, whereas classification was less successful with the other types of tumours such as germ cell tumours, tumours of the sexually differentiated stroma, metastases and tubo-ovarial abscesses.
The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film ...
The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film ...
The objective of this study was to develop a method for 3D subtraction CT angiography and to optimize the visualization after semiautomatic segmentation. Ten patients with aneurysms of the abdominal aorta were examined using spiral CT. To reconstruct the vessels, as well as adjacent organs such as the liver and kidneys, one image data volume was acquired before and after injection of the contrast agent. The CT scans were obtained with a Siemens Somatom Plus 4. To improve the results of automatic segmentation, as well as visualization by maximum intensity projection (i.e. removal of bony structures), subtraction of both image volumes is necessary. However, small translation shifts disturb the subtraction process and produce artificial contours. To calculate the disparities along the three coordinate axes of two corresponding image volumes, a cepstrum filter is ...
The use of magnetic resonance imaging for diagnosis and the preoperative staging of renal cell carconoma was evaluated in 79 patients with 88 tumors. Gradient-echo and spin-echo images before and after intravenous administration of Gadolinium DTPA were compared with the results of computed tomography (CT) and histologic staging. The two imaging techniques had comparable results: T-stage was predicted correctly with CT in 78%.4% and with MRI in 84.0% of the cases, while the N-stage was accurately assessed in 81.8% and 79.5%, respectively. MRI had some advantages in diagnosing perirental tumor spread and in excluding an infiltration beyond Gerota's fascia. Therefore, MRI is a true alternative to CT for staging large renal cell carcinomas and especially for patients with contraindications for iodinated contrast agents. (orig.).
The authors have been developing a 3D brain CTimage display system for planning of craniofacial operations. This system helps doctors plan craniofacial operations on a graphic display (GD) terminal by rendering 3D images reconstructed from a set of slices. The authors reveal how the system generates 3D shapes of organs from given CTimages and how it modifies or transforms the obtained shapes according to the user's request. The system functions now available are extraction and display of the skull and the skin, measurement of the distance between two points on the skull given through the GD terminal, and generating and eliminating a polygonal region arbitrarily given on the skull as an operative region. (Auth.).
Magnetic resonance imaging can be used in the trauma setting to detect fractures and associated soft tissue injuries of the musculoskeletal system. Magnetic resonance imaging complements plain radiography and CT for evaluating cancellous bone, cartilage and growth-plate injuries, and intra- and extraarticular supporting soft tissue structures. This review outlines typical applications and imaging consideration for injuries of the pelvis and lower extremity. (orig.) With 12 figs., 78 refs.
Image registrations that are based on similarity measures simply adjust the parameters of an appropriate spatial transformation model until the similarity measure reaches an optimum. The numerous similarity measures that have been proposed in the past are differently sensitive to imaging modality, image content and differences in the image content, selection of the floating and target image, partial image overlap, etc. In this paper, we evaluate and compare 12 similarity measures for the rigid registration. To study the impact of different imaging modalities on the behavior of similarity measures, we have used 16 CT/MR and 6 PET/MR image pairs with known 'gold standard' registrations. The results for the PET/MR registration and for the registration of CT to both ...
A new monolithic semi-insulating (SI) GaAs sensor design for X-rayimaging applications between 10-100keV has been proposed. Monolithic pixel detectors offer a number of advantages over hybrid bump-bonded detectors, such as high device yield, low costs and are easier to produce large scale arrays. In this thesis, an investigation is made of the use of a SI GaAs wafer as both a detector element and substrate for the epitaxially grown High Electron Mobility Transistors (HEMTs). The design of the HEMT transistors, optimised for this application, were produced with the aid of the Silvaco 'Virtual Wafer Fab' simulation package. It was determined that the device characteristics would consist of a small positive threshold voltage, a low off-state drain current and high transconductance. The final HEMT transistor design, that would be integrated to a pixel detector, had a threshold voltage of 0.17V, an off-state leakage current of approx 1nA and a ...
The shell integrity near peak compression of spherical implosions using the 60-beam, 30-kJ UV OMEGA laser system [Opt. Commun. 133, 495 (1997)] has been measured. Hot core emission backlights a shell with a thin titanium-doped layer that is imaged at x-ray photon energies above and below the titanium K edge. The x-ray intensity ratio between the two images is related to perturbations in the cold, or absorbing, part of the shell. The measured cold-shell areal-density modulations, integrated over the time of peak compression, are of the order of 25% to 50% with nonuniformity spectra peaked at spatial wavelengths of 30 to 50 #mu#m and with the smallest detectable nonuniformity features extending down to spatial wavelengths of 12 to 15 #mu#m. Hot-shell areal-density modulations of the emitting part of the shell (inner edge) are of the order of 13% to 20%. The measured shell modulations are in agreement with ...
Purpose: To evaluate the significance of preoperative localization of abnormal parathyroid glands to the surgical outcome in patients with primary hyperparathyroidism. Material and Methods: Thirty-nine patients with primary hyperparathyroidism were studied preoperatively with US (39 patients), CT (30 patients) and MR imaging (18 patients). The overall diagnostic accuracy for US was 87%, CT 66% and MR 94%. In patients with a single parathyroid adenoma US was the most cost-effective localization technique with a detection rate of 96%. CT had a lower detection rate (78%) but was of particular value for fairly large ectopic adenomas in the root of the neck. MR imaging was a good confirmatory test (93%). In patients with multiple gland disease (primary hyperplasia and multiple adenomas), no single localization study alone was sufficient. Combination of all 3 studies, however, alerted the ...
The contribution of US, CT and MR imaging was investigated in 25 cirrhotic patients with hepatocellular carcinoma. The following parameters were considered: lesion detection, site and size of the lesion, daughter nodules, location and/or infiltration of intrahepatic vessels, patency of portal vein and collateral vessels, signs of chronic liver disease, steatosis, ascitis, and lymphadenopathy. The results confirm the value of US, which also allowed lesion biopsy in all cases. CT was as accurate as US in detecting the lesion and even superior in demonstranting daughter nodules. MR imaging, with conventional SE and IR sequences, was inferior since it missed 3 lesions due to motion artifacts; more over, a smaller number of daughter nodules was seen than with CT. The authors conclude that, at present, MR imaging cannot replace US and CT; the ...
The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).
The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).
In an effort to explore Diffraction Enhanced Imaging of bone tissue, experiments were performed to determine if it was possible to use Diffraction Enhanced Imaging to detect microdamage in bovine cortical bone. Measurements were made at the National Synchrotron Light Source where pre- and post-fatigue rocking curve widths of the bone were studied. The rocking curve widths were then compared. Since no consistent pattern of narrowing or broadening of the rocking curve emerged, it is likely that the ultra-small-angle X-ray scattering present in the bone overshadowed any additional changes to rocking curve caused by microdamage of the bone. Larger bone structures were able to be visualized which suggests that microdamage may be visualized with a higher resolution detector.
In an extended case report, we discuss four cases with masses in the lacrimal fossa representing the most important entities in this region (lymphoma, pleomorphadenoma, inflammatory pseudotumor, and malignant epithelial tumor). The different indications for CT and MRI are explained. For the differential diagnosis of lacrimal gland lesions, the following imaging parameters are important: The shape of the lacrimal gland, the inner structure, the degree of contrast enhancement, and the surrounding bony structures. In the evaluation of the expansion of lacrimal gland lesions, CT in thin slices with multiplanar reconstructions is equal to MRI. However, the contrast-enhancement of lacrimal glands is better evaluated with MRI than with CT. The bony structures are better visualized on CT than on MRI. (orig.).
There are many differences between industrial CT and industrial radiography, such as imaging principle, inspection time, radiation dose and the requirements for operators etc. The national standards for radiation protection of industrial detection are not applicable to the requirements of protection and safety for #gamma#-ray industrial CT to some extent now. In order to standardize the production and use for #gamma#-ray industrial CT, protect the safety of operators and the public, and to promote the popularization and application of #gamma#-ray industrial CT, it is significant to establish the national standards for radiation protection of #gamma#-ray industrial CT as soon as possible. The purpose of this paper is to introduce the contents of this standard, and specify some important terms. Then there is a brief discussion on the existing problems during ...
we report an ultrafast synchrotron x-ray phase contrast imaging study of the primary breakup mechanism of a coaxial air-assisted water jet. We demonstrate that there exist great similarities in the phenomenology of primary breakup with that of the secondary breakup. Especially, a membrane-mediated breakup mechanism dominates the breakup process for a wide range of air speeds. This finding reveals the intrinsic connections of these two breakup regimes and has deep implications on the unified theoretical approach in treating the breakup mechanism of high speed liquid jet.
The paper presents information in the form of data, tables and diagrams compiled to a broad but very up-to-date survey of required radiation for the various most frequently performed X-ray examinations of patients. The required dose is discussed from the point of view of radiation protection, defining the inevitably administered dose to the skin, the frequency of examinations, and the diagnostic image quality as the main three factors to be observed, as these determine the radiation dose to the patient and to the personnel. The somatic risks of radiography examinations are a point of main interest. (DG).
Most of the investigations have a theoretical sustenance based on molecular simulation. The area of application of molecular simulation is very wide, in the Materials Technology Department assigned to the Applied Sciences Management have been treated problems about metallic nano structures, glasses, interfaces, and molecules, to sustain and to explain some of the experimental results. Energy calculations are carried out to determine minimum energy structures, for later on to carry out calculations of some of their properties; as well as the images simulation of Electron microscopy and X-ray diffraction. (Author)
A 3"1/_2-year-old child developed unilateral diaphragmatic paralysis after chest drain insertion. Plain chest X-ray demonstrated paravertebral positioning of the chest-tube tip, and magnetic resonance imaging revealed hematomas in the region of the chest-tube tip and the phrenic nerve fibers. The trauma to the phrenic nerve was apparently secondary to malposition of the chest tube. This is a rare complication and has been reported mainly in neonates. Radiologists should notify the treating physicians that the correct position of a chest drain tip is at least 2 cm distant from the vertebrae. (orig.)
Leukodystrophies are inherited white matter diseases due to abnormalities occurring in myelin synthesis and/or maintenance. The most common types of these rare childhood conditions are represented by adrenoleukodystrophy, metachromatic leukodystrophy, Canavan's, Alexander's, Krabbe's, and Pelizaeus-Merzbacher's diseases. Most of them are lethal during childhood, with the exception of the adrenoleukodystrophy-adrenomyeloneuropathy complex, which sometimes, during its early phases, may be cured with a dietary therapy. The aims of this paper are: 1) the description of inheritance factors, pathogenesis, pathological and clinical findings of each of the most frequent childhood leukodystrophies; 2) the description of the most common patterns of these conditions on CT and MR imaging; 3) the evaluation of the diagnostic capabilities of these two imaging techniques and the comparison of their results. Finally, some of the therapies ...
Commercially available CT devices reconstruct cross-sectional slices of the human body. A sequence of such abutting cross-sectional slices can be, and usually is, used to obtain information about the region of the head, which requires several slices to cover it. However, there are situations for which such asequence of displays is far from optimal - for example, when one would like to see the anatomic relationship between two features appearing in different slices or the shape of a particular region or tumor. The Computer Aided Three-Dimensional Reconstruction and Imaging System (CATRIS), developed at our university, can build up a three-dimensional image from a series of CT cross-sections and can display its stereoscopic image on a three-dimensional graphic display system, thus providing helpful information for clinical use in recognizing the anatomic relationship between two ...
Brain CTimages were reviewed of 98 schizophrenic patients and 90 healthy persons in relation to handedness and aging. CTimages were further reconstructed to examine morphologically subtle changes in each region. Schizophrenic patients had progressive brain atrophy and dilated lateral ventricles, especially on the left side and in the posterior part of the lateral ventricle. These findings were more marked in left-handed than in right-handed schizophrenic patients. According to age groups, there were significant differences between schizophrenic and normal persons over the age of 40. The incidence of left handedness was significantly higher in schizophrenic patients in their fourties than the age-matched normal persons (31.4% vs 15.1%). Morphological abnormality and laterality might be due to the same pathologic consequences. (N.K.).
Circularly polarized X-rays produced by a diamond X-ray phase retarder of thickness 0.5 mm in the Laue transmission configuration have been used for recording X-ray magnetic circular dichroism...Full Text Available
To assess the diagnostic capability Fuji computed radiography (FCR) using a dual side reading system was compared to the conventional radiography using a film-screen system. Twenty-eight patients with lung cancer were examined with a new FCR system (FCR 5501D) and a conventional screen-film system concurrently. FCR utilizes a reading system that detects emissions from dual sides of imaging plate. Chest X-rays were obtained with same exposure factors in both systems. Image qualities of both systems were compared by two radiologists using a five-level score. There were no lesion that FCR images were inferior to film-screen images. The frequency of score +1 or +2 that FCR images were superior to film-screen images was 31% in large nodular shadows, 40% in accompanying shadows with a nodule, 67% of small nodular shadows, and 43% of the lymph node ...
Differentiating a benign from a malignant lesion by information such as density data, or signal intensities or echo gradients, is not possible with CT, nor MRI, nor ultrasonography. Only some lesions show characteristic signs. Inflammations cannot be difscriminated from malignant tumors. CTs of small tumors in particular are so poor in contrast that it is much more difficult to detect tumors or discriminate them from other lesions, as compared to MR images or ultrasonographs. CT does not detect surface tumors, but is more sensitive than MRI or US in detecting discrete cortical bone lesions. The same applies to small calcified tumors. MRI however is most sensitive in detecting tumor volumes in the yellow marrow, and is the best modality for evaluation of extraossal extension of tumors. CT yields better results than MRI if applied for simultaneous screening of lymph node metastases in the lower neck. MRI ...
In less than a decade computed tomography (CT scanning) had a profound impact on diagnostic radiology. Radiology of the orbit is no exception. As early as 1973, reports published in the radiological literature indicated that this new noninvasive imaging method was a highly effective way of demonstrating intraorbital mass lesions. As CT scanners became widely available, computed tomography became a significant adjunct to ophthalmological diagnosis. Today the main indications for CT scanning of the orbit are: (1) suspected mass lesions, most frequently presenting as exophthalmos, (2) orbital trauma, including foreign bodies, (3) some congenital anomalies, and (4) suspicion of extension into the orbit of extraorbital disease processes. Along with ultrasonography, another new noninvasive imaging technique, CT has replaced a number of more invasive and often less ...
In a prospective study, 58 patients with carcinomas of the bladder were examined by CT and MRI; in 48, gadolinium-DTPA was administered intravenously. MRI provided exact staging in 89%, compared with 80% with CT. There was 13% over-staging with CT and 11% with MRI. MRI, unlike CT did not result in any under-staging. In 36 patients a quotient could be calculated from the signal intensity of the tumour and surrounding soft tissues both before and after the intravenous contrast medium and the increased quotient after contrast administration could be estimated. There was a significant increase in the tumour/muscle quotient with a mean of 72#+-#22% (minimum 43%, maximum 153%), corresponding to a marked increase of the signal form the tumour when compared with the precontrast images. This had the following advantages compared with CT: Accurate differentiation between ...
We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.).
Primary peritoneal malignant mixed mullerian tumors are very rare. We report the case of a patient presenting with pain in the right upper quadrant of the abdomen and in whom the physical examination demonstrated a peritoneal mass. Computed tomography (CT) confirmed the presence of a mass, with invasion of adjacent organs.
The usefulness of helical CT early phase images optimized by the SmartPrep method for evaluation of wall invasion by colorectal cancer was investigated. Between August 1997 and September 1998, CT was performed to evaluate the primary tumor and local extension in 10 consecutive patients with colorectal cancer confirmed by barium enema- and/or colonoscopy. Early-phase images were acquired by using SmartPrep application software. This method allows the optimal scan delay time to be obtained by continuous monitoring of increases in CT values after injection of contrast medium. Sections of the surgical specimens, close to the same plane as the CTimages, and of the same slice thickness, were analyzed histopathologically. All 10 cancers, regardless of size, showed strong enhancement on the early-phase images (81.4-112 HU, ...
Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)
A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.
The authors propose a method for determining the risk of femoral neck fracture in osteoporotic patients that is not based on densitometric techniques. The method is based on a structural analysis performed by a computer on data taken from a single digital anteroposterior projection of the hip. From the image, the effective cross-sectional area and cross-sectional moment of inertia are computed from attenuation principles. Together with other geometric measurements, these data are used in an engineering analysis to compute the yield strength of the proximal femur, under stress applied through the acetabulum in a one-legged stance. An index of fracture risk based on the ratio of estimated yield strength to body weight is proposed. Ultimately it is expected that this work will allow the clinician to estimate hip fracture risk in osteoporotic patient using widely available existing technology, a goal which has eluded bone density-based methods.
The properties and kinetics of x-ray stars in globular clusters are described. Locations, configurations, star evolution, massive close binary systems, various mechanisms, and the x-ray burster properties are included. (JFP)
A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.
The issue of beam-induced damage on diffractive hard X-ray optics is addressed. For this purpose a systematic study on the radiation damage induced by a high-power X-ray beam is carried out in both...Full Text Available
For the first time, rheological phase method, a simple and effective route, is applied to synthesize novel cathode material LiCoPO{sub 4}. X-ray diffraction spectrometer (XRD), X-ray photoelectron spectrometer (XPS), transmission electron microscope (TEM) and electrochemical impedance spectroscopy (EIS) are taken to investigate this material, respectively. XRD figure shows that the rheological sample is better crystallized than the solid-state one. XPS result of the rheological sample exhibits that the valence of Co is 2+. TEM images show that better dispersed particles with smaller size can be formed by rheological method comparing to the solid-state route. Charge-discharge test is carried out in the range of 3.0-5.0 V at 0.2 mA cm{sup -2}. The initial discharge capacity for rheological phase and solid-state powder is 71.5 and 30.9 mAh g{sup -1}, respectively. The better electrochemical property should be ascribed to the ...
For the first time, rheological phase method, a simple and effective route, is applied to synthesize novel cathode material LiCoPO4. X-ray diffraction spectrometer (XRD), X-ray photoelectron spectrometer (XPS), transmission electron microscope (TEM) and electrochemical impedance spectroscopy (EIS) are taken to investigate this material, respectively. XRD figure shows that the rheological sample is better crystallized than the solid-state one. XPS result of the rheological sample exhibits that the valence of Co is 2+. TEM images show that better dispersed particles with smaller size can be formed by rheological method comparing to the solid-state route. Charge-discharge test is carried out in the range of 3.0-5.0 V at 0.2 mA cm-2. The initial discharge capacity for rheological phase and solid-state powder is 71.5 and 30.9 mAh g-1, respectively. The better electrochemical property should be ascribed to the better crystallized ...
Focused Ion Beam (FIB) milling is a powerful tool to produce ordered magnetic nanostructures. However, it is impossible to produce out-of-plane magnetized nanoscale structures from multilayer films by direct FIB writing. Co/Pt multilayers exhibit an out-of-plane easy axis due to strong perpendicular interface anisotropy. The interface contribution is known to be very sensitive to high energy ion irradiation. In case of 30 keV Ga ions it needs less than one ion per 100 surface atoms to destroy the perpendicular interface anisotropy. We demonstrate how this problem can be overcome by milling a Co/Pt multilayer, which has been deposited on a SiN membrane, from the rear side, through the SiN. The effect of the ions is determined as a function of applied dose utilizing the domain structure imaged by soft X-ray holography. When the magnetic material is removed we find only a very narrow range of destruction around the holes in contrast to the ...
Cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) have been regarded as promising semiconductor materials for hard X-ray and Gamma-ray detection. The high atomic number of the materials (Z_{Cd} =48, Z_{Te} =52) gives a high quantum efficiency in comparison with Si. The large band-gap energy (Eg ~ 1.5 eV) allows us to operate the detector at room temperature. However, a considerable amount of charge loss in these detectors produces a reduced energy resolution. This problem arises due to the low mobility and short lifetime of holes. Recently, significant improvements have been achieved to improve the spectral properties based on the advances in the production of crystals and in the design of electrodes. In this overview talk, we summarize (1) advantages and disadvantages of CdTe and CdZnTe semiconductor detectors and (2) technique for improving energy resolution and photopeak efficiencies. Applications of these imaging detectors in ...
We describe a camera to record coherent scattering patterns with a soft-x-ray free-electron laser (FEL). The camera consists of a laterally graded multilayer mirror, which reflects the diffraction pattern onto a CCD detector. The mirror acts as a bandpass filter for both the wavelength and the angle, which isolates the desired scattering pattern from nonsample scattering or incoherent emission from the sample. The mirror also solves the particular problem of the extreme intensity of the FEL pulses, which are focused to greater than 10"1"4 W/cm"2. The strong undiffracted pulse passes through a hole in the mirror and propagates onto a beam dump at a distance behind the instrument rather than interacting with a beam stop placed near the CCD. The camera concept is extendable for the full range of the fundamental wavelength of the free electron laser in Hamburg (FLASH) FEL (i.e., between 6 and 60 nm) and into the water window. We have fabricated and tested various ...
A computerized system for monitoring dose-area product (DAP) has been developed for region of interest (ROI) fluoroscopy in which patient exposure is reduced using an x-ray attenuating filter with an aperture. The system includes an IBM compatible computer which is connected through an IEEE-488 interface to an electrometer which measures the charge from a DAP ionization chamber. A digital input/output board connects the computer to the filter placement device to determine whether the filter is in or out of the beam, and to the x-ray generator to determine when the exposure is due to spot filming. The computer logs the DAP from conventional fluoroscopy, ROI fluoroscopy and spot filming separately, applying the appropriate calibration factor for each. Measured DAPs, fluoroscopic DAP rates and exposure times are displayed in real-time. The system has been installed in a GI fluoroscopic room so that the dose-reduction potential of ROI ...
Motivation: Cell tracking is an important method to quantitatively analyze time-lapse microscopy data. While numerous methods and tools exist for tracking cells in 2D time-lapse images,...Full Text Available
In our evaluation we utilized the Asahi Mark-J NMR-CT system, with a resistive vertical quadrupolar electromagnet (0.1 Tesla) and a proton resonance frequency of 4.5 MHz. Our main imaging methods are the inversion-recovery or IR, saturation-recovery, or SR, and calculated T/sub 1/. Difference, or D images, constructed by subtracting the data of the IR signal from that of the SR signal, have also been obtained in some cases. The system allows averaging of raw data. Hybrid images were constructed from two or more images to obtain clear definition of areas of interest. By using the hybrid image, several tissues of different relaxation times can be shown in the same image. Application in our study of the newly developed hybrid image indicates its importance in the detection and diagnosis of lesion, especially the detection ...
The X-ray photoacoustic spectra of copper and brass (64.7 wt.% Cu and 35.3 wt.% Zn) have been measured at XANES (X-ray absorption near-edge structure) regions using synchrotron radiation. These spectra were compared with optical density of X-ray spectra. It is shown that the information derived from XANES is also included in the X-ray photoacoustic spectrum which reflects the heat production processes in copper and brass. However, the results showed that the increases and changes of the photoacoustic signal were different from those of the X-ray absorption coefficient at XANES regions. (author).
High interelectrode voltage peaks have been observed simultaneously with the emission of hard X-ray bursts from a flash X-ray tube. The magnitude of the voltage peaks may exceed twice the initial charging voltage. It has also been observed that the discharge emits bursts of X-and P-band microwaves radiation which are coincident with the emission of the hard X-ray bursts. The results indicate that the microwaves and X-rays have a common origin in discharge plasma movements and an acceleration model for electrons in the plasma is presented as one possible explanation of the observed phenomena.
A technique was developed that permits fluid flow to be visualized even where the flow is completely shrouded by metal. The technique employs real-time neutron radiography, which is similar to x-ray radiography except a collimated beam of neutrons is used. Various combinations of neutron-opaque tracer materials were tested with neutron-transparent fluid. Neutron opaque tracers, such as solid particles, fluid droplets, and streaklines were imaged through metal walls as they convected in neutron-transparent ambient fluid. Visualization of bubbles/voids were evaluated for possible future applications. Surface-flow patterns were also imaged by using neutron-opaque tufts. These techniques were evaluated for image contrast, resolution, and the ability to accurately track fluid flow fields. The techniques were also modeled to optimize contrast in various flow configurations. Imaging ...
A technique was developed that permits fluid flow to be visualized even where the flow is completely shrouded by metal. The technique employs real-time neutron radiography, which is similar to x-ray radiography except a collimated beam of neutrons is used. Various combinations of neutron-opaque tracer materials were tested with neutron-transparent fluid. Neutron opaque tracers, such as solid particles, fluid droplets, and streaklines were imaged through metal walls as they convected in neutron-transparent ambient fluid. Visualization of bubbles/voids were evaluated for possible future applications. Surface-flow patterns were also imaged by using neutron-opaque tufts. These techniques were evaluated for image contrast, resolution, and the ability to accurately track fluid flow fields. The techniques were also modeled to optimize contrast in various flow configurations. Imaging ...
Neutron radiography and neutron radioscopy are rapidly becoming the valuable tools for nondestructive testing and basic research. The Phoenix Memorial Laboratory has developed a neutron facility capable of both film neutron radiography and real time neutron radioscopy, and has used this facility to study several phenomena of interest to the researchers in many areas. Neutrons can be used for imaging the phenomena that X-ray cannot image, such as the presence, absence or movement of hydrogenous materials inside metals such as aluminum or steel. There are three basic methods for obtaining images using neutrons: high resolution film neutron radiography, real-time neutron radioscopy and transfer film neutron radiography. The neutron radiography facility at Phoenix Memorial Laboratory, the neutron radioscopic imaging systems, the neutron radiographic detectors, lubrication studies, spray ...
The purpose of this study was to evaluate time management and workflow for multidetector-row helical CT (MDCT). Time for patient and data handling of at total of 580 patients were evaluated at two different time periods (December 1999, August 2000), each for the following baseline measurements: (a) change of clothes/instruction; (b) patient placement on the CT table/i.v. catheter; (c) CT planning and programming; (d) CT data acquisition; (e) CT data reconstruction; (f) CT data storage/printing. All imaging was performed on a Somatom Volume Zoom (Siemens, Erlangen, Germany). Time measurements summarized for different CT protocols revealed the following: (a) 5:01 min (#+-#2.06 min); (b) 4:36 min (#+-#2.43 min); (c) 4:11 min (#+-#2.55 min); (d) 0:43 min (#+-#0.15 min); (e) 6:59 min (#+-#2.39 min); (f) 09:51 min (#+-#3.51 ...
The enhancements described of high-performance CT systems of latest design have again confirmed the importance of CT systems for acute and selective diagnostic imaging. Higher availability, shorter exposure times, and better applicability and handling for examination of poly-traumata patients or patients of intensive care departments are some of the advantages achieved with CT systems which demonstrate CT system efficiency in addition to MRI, which for specific examinations will remain the modality of first choice for diagnostic evaluation. The Tomoscan Av-E presented here was able to answer all relevant diagnostic questions appearing in routine diagnostics and scientific work. For patients, examinations using the spiral CT technique also offers significant advantages. (orig./CB) [Deutsch] Durch die dargestellten Verbesserungen bei ...
Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are ...
Bowel infarction is a rare and typical condition of the elderly; despite improvements in diagnostic imaging and vascular surgery, bowel infarction remains a major cause of acute abdomen, with mortality rates ranging 70-80%. Diagnosis on often late because clinical sings, laboratory data and radiologic findings are a specific. The authors investigated radiographic and particular CT patterns of intestinal infraction in 56 patients submitted to surgery within 12 hours of admission. We also report the CT findings of 5 of these patients who had reversible mesenteric ischemia. CT is more sensitive than radiography and does not exhibit the limitations of angiography (i.e., invasiveness, radiation exposure an complex organization. Therefore CT can presently be considered the method of choice in patients with suspected bowel infarction.
Twenty-two out of 31 patients with chronic renal failure and secondary hyperparathyroidism who underwent parathyroidectomy before operation underwent non-invasive image diagnosis of parathyroid glands by computed tomography (CT), scintigraphy with /sup 201/TlCl and /sup 99m/TcO/sup 4 +/, and/or ultrasonography. CT visualized 39 of 45 parathyroid glands (86.7%), weighing more than 500 mg. Scintigraphy with a subtraction method using a computer performed the diagnosis in 19 of 27 glands (70.4%). Ultrasonography detected 21 of 27 glands (77.8%). Image diagnosis was also useful in the postoperative follow-up study. The non-invasive image diagnosis of parathyroid glands in patients with chronic renal failure is thus valuable for 1) definite diagnosis of secondary hyperparathyroidism, 2) localization, and 3) diagnosis for effectiveness of conservative treatment.
Hepatocellular carcinoma (HCC) is characterized by tumor vascularization from the hepatic artery. The objective of our work was to compare color Doppler ultrasonography (CDU), including power Doppler ultrasonography (PDU) with radiographic imagings with contrast medium in regard to the detection of the arterial tumor vascularity of small hepatocellular carcinomas (HCC). We examined 42 small HCC lesions 2 cm or less in diameter in 37 patients for arterial tumor vascularity by conventional CDU, PDU, dynamic computed tomography (dCT), digital subtraction angiography (DSA), and CT hepatic arteriography (CTA). Color images were detected in 25 (59.5%) and 28 (66.7%) of the 42 lesions with conventional CDU and PDU, respectively, and tumor vascularity was detected in 26 (61.9%) by dCT, 23 (54.8%) by DSA, and 29 (69.0%) by CTA. Tumor vascularity could be detected in 51.9% by PDU and CTA, ...
MRI findings in 13 patients with monolateral parotid tumor were compared with US, sialographic and CT findings. MRI did not allow an accurate diagnosis in 2 patients with diffuse chronic parotitis. MRI was superior to CT in 1 case in defining the intraglandular site of the lesion, and in 2 patients in showing the extraglandular involvement. MRI proved to be superior to CT thanks to its contrast resolution and to multiplanar imaging. MRI high contrast resolution made it possible to demonstrate neoplastic lesions of 4 mm in diameter. The lesion has low signal intensity on T1-weighted images and high signal intensity on T2-weighted. Parotid tumors cannot be characterized by signal intensity alone: only morphology allows to discriminate between benign and malignant lesions. To conclude, US is a screening method, while MRI is helpful in detecting multifocal lesions and in evaluating the ...
Subjects were 18 cases with adenocarcinoma of 20 mm or less in diameter, which were detected and resected surgically from September, 1993 to August, 1998. On these cases, thin-Section CT (TSCT) images were compared with pathological findings. Patients were 15 men and 3 women, with mean age of 63.4-year-old. An average tumor size was 11.5 mm (5-17 mm). According to pathological classification of Noguchi, type A as in 6 cases, type B in 3, type C in 7 and type F in 2. TSCT was carried by vas voltage =150 kVp, vas current =200 mA, beam width =2 mm, WW =2000 HU, and WL =-700 HU. The ratio of CT attenuation value in cancer by TSCT correlated with the ratio of aeration rate in the pathologic specimen. The cases of 30% or less on the ratio of CT attenuation value were 100% in types A and B, and 71% in type C. These results suggested that it is necessary to devide into two type in group of type C and the ratio ...
Thirty-five patients with temporal bone fractures were examined; the fractures were sometimes associated with dislocation of the assicular chain caused by road fatalities. Computed Tomography (CT) was performed either because of the presence of clinical symptoms associated with trauma of the temporal bone, because of a hemotympanum discovered during a CT scan of the brain. Thirty-three fractures were detected: 19 longitudinal, 6 transverse, and 8 complex. An incudostapedial dislocation was also detected, together with a displacement of a stapedial prosthesis from the lenticular process of incus, and 3 incus-malleus dislocation associated with fractures. High resolution CT allows the precise definition of the course of the fractures, of the associated dislocation of the ossicular chain, and of facial nerve lesion, thus allowing a more accurate surgical intervention. In the examination of the temporal bone, high resolution ...
CT scans were performed on 25 patients suspected of sustaining ranal trauma. The utility of CT in both detecting renal damage and appraising the gravity of injuries was assessed. Nowadays, in fact, nephrectomy or reserved for lesions devastanting the kidney parenchyma or rupturing the renal pedicle; so it is very important to identyfy both the purposes of a better planned therapeutic approach. CT does both, being more accurate than urography in the detection of renal fractures, intra or extraparenchymal hematomas and contrast media extravasation. Urography very often shows aspecific lesion patterns and sometimes it is also falsely negative. In the present series CT was more reliable than angiography itself, particulary in the diagnosis of extra-renal hematic collections, contrast media extravasation and injuries to the other abdominal organs. Although CT may arouse the suspicion of ...
The effect of resonance, observed in X-ray waveguide layered structures in a characteristic way influences the scattering properties of the films. It is well known that the resonant region in the reflectivity shows a series of minima, usually very deep and extremely narrow. The positions and depths of the minima depend only on X-ray waveguide and quasi X-ray waveguide film structural properties, on the X-ray wavelength and on the incident beam divergence. In the present work we propose and discuss the application of the X-ray waveguide and quasi X-ray waveguide film structures as a tools to experimental evaluation of some quantities related to X-ray reflectometric and diffractometric measurements, like the beam divergence, wavelength, or angular distance. Examples of application of X-ray waveguide as an excellent tool ...
Subject of this study is the question of whether cone beam CT (CBCT) images with reduced projection data are suitable for use in adaptive radiation therapy (ART) treatment planning. For this purpose image quality and dose calculation accuracy depending on imaging modality were analysed. In this context, two CBCT-methods will be indicated having reduced projection data sets: Scans acquired with 200^o rotation angle in order to accelerate the CBCT process (half scan), or scans with an asymmetric cone beam and detector offset, used to enlarge the field-of-view (half fan). Methods: For three different CBCT-modes (On-Board-Imaging, Varian Medical Systems), two of them based on reduced projection data, and a conventional multidetector CT system, the main image quality parameters were studied. Tr...
Integration of positron emission tomography (PET) and magnetic resonance (MR) has become a topic of increasing interest to the imaging community over the past two years. In this text, the authors attempt to distinguish facts from fiction concerning such integrated systems. Analysis of existing information of combined imaging on existing brain PET/MR systems and imaging experience with PET-computed tomography (CT) is reviewed. Various types of system integration of PET and MR are discussed with completely independent systems on one hand and completely integrated systems with the possibility of simultaneous data acquisition on the other hand. Furthermore, it is discussed, what simultaneous data acquisition with nuclear imaging systems combined with MR or CT really means, as technical simultaneity may not be relevant in light of the pharmacokinetics of the nuclear ...
To analyze and review the most common focal lesions of the external auditory canal (EAC), describing the computed tomography (CT) findings. The CTimages of EAC were reviewed in a series of 167 patients. Abnormal findings were recorded in 13 cases. The CTimages were correlated with otoscopic and/or intraoperative findings. There were four cases of osteoma (one located outside the EAC); all of which were treated surgically, as was the one case of exostosis. Six patients presented debris in EAC, coinciding with clinical evidence of external otitis. There were two cholesteatomas derived from EAC, one of them secondary to survery to treat osteoma. On patient was diagnosed as having a basal cell carcinoma of the ear, extending to EAC, but refused to undergo surgery. Five patients presented small triangular laminae of dense bone arising from the upper wall of the EAC which were defined ...
CT and MRI of acquired abnormalities of the inner ear and cerebello-pontine angle present themselves with very typical findings. The imaging should be adapted to the pathology looked for and either CT or MRI should be used alone or in combination.CT, especially high resolution CT (HRCT), provides an excellent bone contrast, while MRI has a much superior soft tissue contrast. Acute inflammatory changes of the inner ear are solely depicted by contrast-enhanced MRI. HRCT excellently depicts osseous changes of the inner ear and cerebellopontine angle such as chronic ossifying labyrinthitis occurring after acute labyrinthitis, otosclerotic or traumatic changes. Tumorous changes not yielding to bony changes are best delineated by MRI. Posttraumatic hemorrhage and chronic fibrotic changes within the labyrinth are depicted by MRI, only. In conclusion HRCT and MRI are excellent methods to ...
Purpose of this work is to investigate the role of Helical CT and the usefulness of three-dimensional (3D) imaging for pre-operative planning and follow-up of reconstructive maxillofacial surgery with alloplastic material in neoplastic disease involving this region. From 1996 to 1999 eleven patients were examined with Helical CT and 3D images for planning of maxillofacial plastic and reconstructive surgery for advanced cancer of this anatomically complex region. A 3D-modulated titanium mesh (100%) or micro nets was used to rebuild the anterior surface of maxillary bone and the orbital floor. The mesh was cut to the appropriate size and shape and curved where necessary. Within the residual sinusal cavity a siliconed filling was used surmounting an acrylic prosthesis with dental arch to rebuild the palate. A rehydrated bovine pericardium was affixed and moduled on the borders in two cases only. ...
In an extended case report, we discuss four cases with masses in the lacrimal fossa representing the most important entities in this region (lymphoma, pleomorphadenoma, inflammatory pseudotumor, and malignant epithelial tumor). The different indications for CT and MRI are explained. For the differential diagnosis of lacrimal gland lesions, the following imaging parameters are important: The shape of the lacrimal gland, the inner structure, the degree of contrast enhancement, and the surrounding bony structures. In the evaluation of the expansion of lacrimal gland lesions, CT in thin slices with multiplanar reconstructions is equal to MRI. However, the contrast-enhancement of lacrimal glands is better evaluated with MRI than with CT. The bony structures are better visualized on CT than on MRI. (orig.) [Deutsch] In einem erweiterten Fallbericht wird ueber die vier grossen Entitaeten ...
During their life, intervertebral discs undergo degenerative changes which need not necessarily become lesions. Conventional X-rays do not provide information on the condition of the intervertebral discs, so MRT or CT are recommended as primary techniques as they are non-invasive. Invasive methods like myelography and especially discography should not be used unless a case is highly problematic. In infants with pains in the back, MRT should be carried out as early as possible as there is nearly always an organic cause. (orig.) [German] Die Bandscheibe ist im Laufe des Lebens degenerativen Veraenderungen unterworfen, die klinisch zu Beschwerden fuehren koennen, aber nicht fuehren muessen. Konventionlle Roentgenaufnahmen lassen zwar die Hoehenminderung des Bandscheibenfachs und begleitende knoecherne Veraenderungen erkennen, nicht aber den Zustand der Bandscheibe selbst. Die Beurteilung der Bandscheibe und des Knochens gelingt mit der ...
Authors obtained T1-weighted MRI images of the femoral head after fracture of the femoral neck and classified the signals into four patterns to investigate the sequential changes of the femoral head. The T1-weighted MRI images obtained initially after femoral neck fracture showed a normal pattern in 10 of the 15 hip joints studied. MRI images obtained subsequently still showed the normal signal pattern in eight of the 10 hip joints which had shown the normal pattern in the first MRI, while two of the 10 joints subsequently showed a band pattern. The joint with the homogeneous pattern in the first MRI subsequently showed a band pattern. Of the three joints with an inhomogeneous pattern in the first MRI, two joints showed a subsequent band pattern, and the other a normal pattern. The joints which showed a band pattern continued to show a similar band pattern. Eventually, all hip joints studied showed a normal or band pattern ...
The fundamentals and the technical application methods of the imaging procedures are discussed in detail with regard to their application in medicine. The development of the X-ray contrast media has led to a better tolerance and a significant reduction of risks. Problems relating to radiation protection and radiation exposure are discussed critically. The general point gives an overview of the radiological examination methods and is meant to deepen the understanding of the special techniques and their rationally determined application. The following special part deals with diagnosing of organs in the region of the neck and the thorax. The general basis is the conventional radiological examination. The great increase in information achieved by means of the new imaging methods becomes clear if we look at the diagnostics of the soft tissue of the neck. Computerized tomography and NMR imaging open the view ...
A novel phantom has been developed to measure the modulation transfer function (MTF) in 3D for x-ray computed tomography. The phantom consists of three tungsten wires, positioned nearly orthogonal to each other. Simultaneous measurements of the MTF are taken at various locations along the three orthogonal reconstructed planes. Our computed mammotomography (CmT) system uses a Varian Paxscan 2520 digital x-ray detector which can be positioned anywhere in ~2pi steradian band and can have arbitrary trajectories. With a half-cone beam geometry and with the phantom positioned near the center of rotation, projection images are acquired over 360 degrees. Various 3D orbits are evaluated including vertical axis of rotation and saddle. Reconstructions were performed using an iterative ordered-subsets transmission algorithm on rebinned projection images, using various numbers of iterations. Rotation of ...
Low noise, high resolution and high dose efficiency are the common requirements for most X-rayimaging applications. Especially in medical applications the dose efficiency is a necessity for detector systems. We present the imaging performance of the Medipix2 readout chip bump bonded to a 300 mu m thick Si detector as a function of the detection threshold, a free parameter not available in conventional integrating imaging systems. Spatial resolution has been measured using the modulation transfer function (MTF) and it varies between 8.2 Ip/mm and 11.0 Ip/mm at 70%. An associated measurement of noise power spectrum (NPS) permits us to derive the detective quantum efficiency (DQE) which can be as a high as 25.5 % for a broadband incoming spectrum. The influence of charge diffusion in the sensor together with threshold variation in the readout chip is discussed. Although the Medipix2 system is used in ...
Present day mammography has not been able to make use of the advantages of digital luminescence radiography because of the limited spatial resolution. The recent development of electromagnetic focusing X-ray tube with effective focal spot sizes from 0.04 to 0.12 mm allows radiographic direct magnification with less geometric blur. It is now possible to combine direct magnification mammography with digital luminescence radiography. By combining high quality storage phosphor screens with an HQ-workstation a spatial resolution of 8 lp/mm is possible for 1.7-fold magnification. For 4-fold spot magnification views spatial resolution can be theoretically increased to approx. 20 lp/mm. One important advantage of digital radiography is the possibility of image-postprocessing. This article presents two sets of standard parameters and three sets of image dependent parameters for better imaging of specific ...
To evaluate the role of positron emission tomography-computed tomography (PET-CT) in staging and determining early treatment response to chemotherapy in children with neuroblastoma (NB) and its correlation with the final outcome. Patients and Methods: Seventeen patients of NB with mean age of 51.5 months (age range 2-132 months; 14 males, 3 females) underwent serial "1"8F-fluorodeoxyglucose (FDG) PET-CTimaging. All 17 patients were for staging before any treatment. Twelve of 17 patients underwent "1"3"1I meta-iodobezylguanidine (MIBG) scan and bone scan. MIBG uptake was seen in the primary lesion in 11/12 patients. MIBG uptake in bones was seen in 3/12 patients. All bone lesions were concordant on MIBG and bone scan. Early response to chemotherapy was evaluated after two cycles using PET-CT. A 30% reduction in longest diameter was taken as cut-off value for response on CT based on ...
Monochromator stabilization (MOSTAB) is a feedback control system to stabilize an x-ray beam of synchrotron radiation. It applies a feedback voltage to a piezo electric transducer attached to a double-crystal monochromator. We developed MOSTAB modules and examined their performances using SPring-8 beamlines. The x-ray beam position stabilization using MOSTAB was realized simultaneously with the x-ray beam intensity stabilization. As an example of its application, we performed EXAFS measurement with MOSTAB. (author)
Global angular momentum balance suggests that the neutron stars in Be/X-ray binaries are not spinning in equilibrium. This requires an X-ray lifetime ''approx <'' 10"5 yr, and suggests that there are many 'dead' Be/X-ray binaries in the Galaxy. Some of these may be turned up as millisecond radio pulsars with Be star companions. (author).
X-ray scattering methods suitable for the investigation of the morphology and chemical composition of self-organized quantum dots and quantum wires are reviewed. Their application is demonstrated in experimental examples showing that a combination of small angle X-ray scattering with high-resolution X-ray diffraction can reveal both the shape and the chemical composition of the self-organized objects. (author)
Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localization of abnormalities. The resulting correlation of the anatomical and functional images may clarify the nature of the abnormality and help diagnose or stage the underlying disease. Whereas successful image fusion software has been developed for the brain, only limited success has been achieved for image alignment in other parts of the body. The development and current status of alternative approaches are presented. Dual-modality imaging is described with devices where two modalities are combined and mounted ...
Full text: Introduction. Children, especially premature infants and neonates, are at a much higher risk to obtain an Xray induced disturbance of life - particularly cancer. On the one hand this is due to their longer life expectancy and on the other hand it is due to their higher cell proliferation rate. The paediatric radiology unit of the Inselspital Bern recently installed some of the most advanced Xray equipment nowadays available. It is based on the two latest digital technologies: double read computed radiography (CR) and direct digital radiography (DR). Only the implementation of these digital radiography systems permits the digital acquisition and additionally the analysis of acquired data. The systematic analysis of large amounts of biometric data and exposition data is the basis for further dose reduction and a systematic quality control (QC). Patients are increasingly critical concerning ...
The main objectives of this project are to quantify the changes in fracture porosity and multi-phase transport properties as a function of confining stress. These changes will be integrated into conceptual and numerical models that will improve our ability to predict and optimize fluid transport in fractured system. This report details our progress on: (a) developing the direct experimental measurements of fracture aperture and topology and fluid occupancy using high-resolution x-ray micro-tomography, (b) counter-current fluid transport between the matrix and the fracture, (c) studying the effect of confining stress on the distribution of fracture aperture and two-phase flow, and (d) characterization of shear fractures and their impact on multi-phase flow. The three-dimensional surface that describes the large-scale structure of the fracture in the porous medium can be determined using x-ray micro-tomography with significant accuracy. Several ...
Background Computed tomography (CT) and magnetic resonance (MR) imaging can help diagnose benign adrenal adenomas, but prior studies rely on nonoperative follow-up as proof of a lesion?s benign nature. We examined adrenalectomy tissues to determine if imaging characteristics correlate with histopathologic findings. Methods We retrieved data for 196 consecutive adrenalectomies in 192 patients from 2000 to 2008. Imaging results were considered to signify benign adrenal adenoma if one or more of the following was present: Hounsfield units 60% or relative contrast washout of >40%, or MR with chemical-shift imaging demonstrating loss of signal intensity on out-of-phase images. Results The sensitivity and specif...
The evaluate the signs of aortic intramural hematoma with helical CT and the diagnostic role of this technique in patients with this condition. It was reviewed the CT findings of 396 patients submitted to emergency examinations for suspected aortic dissection from 1995 to 1999. Only 18 patients (6 women and 12 men) had CT signs of aortic intramural hematoma. Helical CT studies were carried out with the following parameters: slice thickness 10 mm, reconstruction index 10, feed 1.5 mm, conventional algorithm with minimum values of 130 kV and 125mA. All patients were examined with dynamic contrast-enhanced CT, before and after a power injection of 130 mL ionic contrast material. It was studied: hematoma localization and longitudinal extension; thickness and density of aortic wall; presence and location of intimal calcifications; integrity of intimal wall; hemo mediastinum and/or hemo ...
T_2 weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T_E=90 ms, T_R=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good quality. Compared with ...
We analyze archived Chandra and XMM-Newton X-ray observations of 536 Sloan Digital Sky Survey (SDSS) Data Release 5 (DR5) quasars (QSOs) at 1.7 <= z <= 2.7 in order to characterize the relative UV and X-ray spectral properties of QSOs that do not have broad UV absorption lines (BALs). We constrain the fraction of X-ray weak, non-BAL QSOs and find that such objects are rare; for example, sources underluminous by a factor of 10 comprise $\\la$2% of optically-selected SDSS QSOs. X-ray luminosities vary with respect to UV emission by a factor of $\\la$2 over several years for most sources. UV continuum reddening and the presence of narrow-line absorbing systems are not strongly associated with X-ray weakness in our sample. X-ray brightness is significantly correlated with UV emission line properties, so that relatively X-ray weak, non-BAL ...
Very high energy (VHE; >100 GeV) observations of a sample of selected active galactic nuclei (AGN) were performed between January 2005 and April 2007 with the High Energy Stereoscopic System (HESS), an array of imaging atmospheric-Cherenkov telescopes. Significant detections are reported elsewhere for many of these objects. Here, integral flux upper limits for twelve candidate very high energy (VHE; >100 GeV) gamma-ray emitters are presented. In addition, results from HESS observations of four known VHE-bright AGN are given although no significant signal is measured. For three of these AGN (1ES 1101-232, 1ES 1218+304, and Mkn 501) simultaneous data were taken with the Suzaku X-ray satellite.
The BL Lacertae object PKS 1413+135 is associated with a disk dominated galaxy which heavily absorbs the BL Lac nucleus at optical and X-ray wavelengths. It has been argued whether this galaxy is actually the host galaxy of PKS 1413+135 or whether the BL Lac is a background QSO, gravitationally lensed by the apparent host galaxy. We have obtained deep high resolution H-band images of this unusual BL Lac object using the UKIRT IRCAM3. Our observations show that the BL Lac nucleus is centered within < 0.05 arcsec of the galaxy. Based on this result we assess the probability for the lensing scenario and come to the conclusion that the disk galaxy is indeed the host of PKS 1413+135. The galaxy shows peanut-shaped isophotes, suggesting the presence of a central bar which is a common feature of AGN
We study the temporal evolution of coronal loops using data from the Solar X-rayImager (SXI) on board of GOES-12. This instrument allows us to follow in detail the full lifetime of coronal loops. The observed light curves suggest three somewhat distinct evolutionary phases: rise, main, and decay. The durations and characteristic timescales of these phases are much longer than a cooling time and indicate that the loop-averaged heating rate increases slowly, reaches a maintenance level, and then decreases slowly. This suggests that a single heating mechanism operates for the entire lifetime of the loop. For monolithic loops, the loop-averaged heating rate is the intrinsic energy release rate of the heating mechanism. For loops that are bundles of impulsively heated strands, it is an indication of the frequency of occurrence of individual heating events, or nanoflares. We show that the timescale of the loop-averaged heating rate is proportional ...
Based on the X-ray crystallographic data of Tc-complexes for brain imaging agents, geometry optimizations in vacuo of TcO-BAT, TcO-MAMA, TcO-L, L-ECD, TcN-BAT and TcN-L, L-ECD complexes are performed with Hartree-Fock method and LANL 2 DZ basis set of G98W program. Then solvation free energy for each Tc-complex mentioned above in water is calculated by polarizable continuum method (PCM) including models of CPCM and IEFPCM. The results show that solvation free energy of Tc-complex is not only an indicator of lipophilicity but also one of the important factors that influence the brain uptake
The morphological aspects of ternary phase formation during the Pd-GaAs reaction have been studied by application of transmission electron microscopy (TEM) and Rutherford backscattering (RBS) techniques. The TEM images show that the first product phase, ''phase I'', forms during deposition of Pd onto (100) GaAs and exhibits the preferred orientation (0001)/sub I/ approx. // (01 anti 1)/sub GaAs/. In the presence of unreacted Pd, the second phase, ''phase II'', nucleates at large-angle grain boundaries in the phase I film as the annealing temperature increases above approx.250C. Energy dispersive analysis of x-rays and RBS suggest the nominal compositions Pd3GaAs and Pd4GaAs for phases I and II, respectively.
In situ synthesis of silver chloride (AgCl) nanoparticles was carried out under ambient conditions in nanoporous bacterial cellulose (BC) membranes as nanoreactors. The growth of the nanoparticles was readily obtained by alternating dipping of BC membranes in the solution of silver nitrate or sodium chloride followed by a rinse step. X-ray diffraction (XRD) patterns indicated the existence of AgCl nanoparticles in the BC and scanning electron microscopy (SEM) images showed that the AgCl nanoparticles well dispersed on the surface of BC and penetrated into the BC network. The AgCl nanoparticle-impregnated BC membranes exhibited high hydrophilic ability and strong antimicrobial activity against Escherichia coli (Gram-negative) and Staphylococcus aureus (Gram-positive). The preparative proced...
A series of sputtered tungsten-carbon multilayer structures with periods ranging from 2 to 12 nm in the as-prepared state and after annealing at 500 degrees C for 4 hours has been studied with high resolution transmission electron microscopy. The evolution with annealing of the microstructure of these multilayers depends on their period.As-prepared structures appear predominantly amorphous from TEM imaging and diffraction. Annealing results in crystallization of the W-rich layers into WC in the larger period samples, and less complete or no crystallization in the smaller period samples. X-ray scattering reveals that annealing expands the period in a systematic way. The layers remain remarkably well-defined after annealing under these conditions.
The energy dispersive beamline X6A at the National Synchrotron Light Source employs a curved crystal monochromator (polychromator) which focuses a range ([similar to]1 keV) of x-ray energies into a narrow (100--120 [mu]m) line image. Although this beamline was constructed primarily for time-dependent EXAFS experiments, we have begun to explore the use of this instrument for energy dispersive diffraction experiments with different types of sample including macromolecular crystals. The tunability ([ital E]=6.5 to 21 keV) and flexibility ([Delta][ital E]=100--1000 eV) of the instrument makes the beamline ideal as a test bed for the application of polychromatic single-crystal diffraction techniques to different chemical or biological materials.
This paper reviews various techniques to harden Charged Coupled Device (CCD) sensors and the results after irradiation of three Thomson n buried channel CCDs having a different degree of hardening. It describes the major irradiation effects on CCD performances and it makes a comparison of the results between the different hardening levels. It shows good results on dark voltage after ionizing radiation for TH 7863M device hardened both by design and by operating conditions (MPP mode) with respect to the standard device TH 7863A. The irradiations were performed with "6"0Co or X-ray (10 keV) sources on devices in operating mode. (author). 3 refs., 8 figs.
The problems are discussed of using radionuclide X-ray fluorescence analysis (the most frequently used source is "2"4"1Am) and neutron activation analysis for monitoring the chemical quality of the working environment of a welder. Elements determinable by these methods are listed and the advantages of the methods stated with regard to speed, simplicity and appropriate accuracy of measurement together with commercial availability of the instruments. Welding as a source of harmful substances is assessed by determination of the amount of chromium in aerosols generated by welding austenitic chromium-nickel steels. The described methods allow to obtain a complex image of the chemical nature of welding aerosols and to understand the mechanism of their impact on the human organism. (J.C.).
Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis studies diffuse infiltration is ...
In order to achieve micro-wound, intelligence and high efficiency for fracture setting, intelligent setting system for fracture is proposed in accordance with biomechanics and fracture therapy theory. In the comprehensive medical system based on C-shape-arm X-machine, image processing and analysis is the core, programmable logical controller and stepping motor are important driving parts controlling mechanical parts. Six degree of freedom dynamics sensor ensures to control accurately force and moment. On the foundation of analyzing X-rayimage peculiarities, method of processing and analysis is put forward, combining time domain with frequency domain. After mining domain knowledge in depth, setting actions is quantized into three non-continuous steps and is parameterized into two angles and one distance aiming at femoral-neck fracture. Objective features are extracted by virtue of three power polymerization curved surface ...
The author's achievements in the title field are summarized and discussed. The following topics are dealt with: (i) principles of radionuclide X-ray fluorescence analysis; (ii) mathematical methods in X-ray fluorescence analysis; (iii) Ross differential filters; (iv) application of radionuclide X-ray fluorescence analysis in the coal industry (with emphasis on the determination of the ash content, sulfur content, and arsenic content of coal); and (v) evaluation of the X-ray fluorescence analyzer from the radiological safety point of view. (P.A.).
Discusses methods for determining ash content in coal using backscattering in X-ray fluorescence. The following aspects are evaluated: principle of ash content determination, energy sources, factors that influence measurement accuracy, reliability. Types of X-ray fluorescence analyzers developed in Czechoslovakia and manufactured in the Czech Republic are comparatively evaluated. Operation of the RPM 113.1 radionuclide X-ray fluorescence analyzer developed by the PAR company and used for measuring ash content in coal and coal calorific value is discussed. 7 refs.
CH Cygni is a symbiotic star consisting of an M giant and an accreting white dwarf, which is known to be a highly variable X-ray source with a complex, two-component, spectra. Here we report on two Suzaku observations of CH Cyg, taken in 2006 January and May, during which the system was seen to be in a soft X-ray bright, hard X-ray faint state. Based on the extraordinary strength of the 6.4 keV fluorescent Fe K-alpha line, we show that the hard X-rays observed with Suzaku are dominated by scattering.
Differentiating a benign from a malignant lesion by information such as density data, or signal intensities or echo gradients, is not possible with CT, nor MRI, nor ultrasonography. Only some lesions show characteristic signs. Inflammations cannot be difscriminated from malignant tumors. CTs of small tumors in particular are so poor in contrast that it is much more difficult to detect tumors or discriminate them from other lesions, as compared to MR images or ultrasonographs. CT does not detect surface tumors, but is more sensitive than MRI or US in detecting discrete cortical bone lesions. The same applies to small calcified tumors. MRI however is most sensitive in detecting tumor volumes in the yellow marrow, and is the best modality for evaluation of extraossal extension of tumors. CT yields better results than MRI if applied for simultaneous screening of lymph node metastases in the lower neck. MRI ...
A computed tomography (CT) cut-off for differentiating neoplastic lesions (polyps/carcinoma) from normal colon in contrast-enhanced CT colonography (CTC) relating to the contrast phase and lesion size is determined. CT values of 64 colonic lesions (27 polyps <10 mm, 13 polyps {>=}10 mm, 24 carcinomas) were determined by region-of-interest (ROI) measurements in 38 patients who underwent contrast-enhanced CTC. In addition, the height (H) of the colonic lesions was measured in CT. CT values were also measured in the aorta (A), superior mesenteric vein (V) and colonic wall. The contrast phase was defined by xA + (1 - x)V using x as a weighting factor for describing the different contrast phases ranging from the pure arterial phase (x=1) over the intermediate phases (x=0.9-0.1) to the pure venous phase (x=0). The CT values of the lesions were correlated ...
A LIXI (Light Intensifier X-rayImage) device has been employed in a real-time neutron radiography system. The LIXI is coupled to a video camera and the real-time images can be observed in a TV monitor, and processed in a computer. In order to get the real-time system operational, the neutron radiography facility installed at the IEA-R1 m nuclear research reactor of the IPEN-CNEN/S P has been optimized. The most important improvements were the neutron/gamma ratio, the effective energy of the neutron beam, decrease of the scattered radiation at the irradiation position, and the additional shielding of the video camera. Several one-frame as well as computer processed images are presented. The overall Modulation Transfer Function for the real-time system was obtained from the resolution parameter p = 0:44 +- 0:04 mm; the system sensitivity, evaluated for a Perspex step wedge, was determined and the average ...
The US study of the posterior compartment of the knee usually allows the clinical suspicion of popliteal cyst to be confirmed. Neverthless, in case of giant Baker's cysts - which are, at any rate, less frequent -US diagnosis is more difficult. CT can help determine the benign nature of the lesion, and hallow an accurate spatial evaluation. Moreover CT, when accurately performed, demonstrates the caudal or cranial cystic spread, together with its clear separation from adjacent muscular tissues. Direct coronal scans are more useful to obtain better spatial definition than reformatted images.
Primary malignant lymphoma of the brain is a disease of unknown etiology, which is increasing in incidence and has an unfavorable prognosis. Despite the lack of specific changes on CT or MRI in most cases, these procedures may typically facilitate the diagnosis: A focal-enhancing mass with subependymal spread on CT or MRI and hyperattenuation on nonenhanced CT are the most reliable features in the diagnosis of primary malignant lymphoma of the brain. Peritumoral edema and mass effect are usually not prominent features. On unenhanced CT scans they usually appear homogeneously isodense to mildly hyperdense relative to the gray matter. On MRI these tumors are slightly hypointense on T1-weighted images and slightly hpyerintense on PD- and T2-weighted images relative to the gray matter. On CT and MRI enhancement is usually homogeneous. ...
Free form fabrication and high resolution imaging techniques enable the creation of biomimetic tissue engineering scaffolds. A 3D CAD model of canine trabecular bone was produced via micro CT and exported to a fused deposition modeler, to produce polybutylene terephthalate (PBT) trabeculated scaffolds and four other scaffold groups of varying pore structures. The five scaffold groups were divided into subgroups (n=6) and compression tested at two load rates (49?N/s and 294?N/s). Two groups were soaked in a 25??C saline solution for 7?days before compression testing. Micro CT was used to compare porosity, connectivity density, and trabecular separation of each scaffold type to a canine trabecular bone sample. At 49?N/s the dry trabecular scaffolds had a compressive stiffness of 4.94?1.19?MP...
A prospective comparative study with pathology was performed to assess the clinical value of Computed Tomography (CT) and endoscopic ultrasound (EUS) for nodal staging in lung cancer. A total of 329 nodal stations were dissected or sampled and 755 lymph nodes were examined at histology. On a pre-station basis, CT had greater sensitivity (74%) than EUS (56%), but EUS was more specific (83% versus 93%). The accuracy rates of the two techniques were similar. In conclusion, endoscopic ultrasound should be part of a routine preoperative diagnostic approach to non-small-cell lung cancer., because of its high specificity. Results can be improved when EUS and CT are combined., which suggests that these imaging modalities should be used together in selected patients for the noninvasive staging of non-small-cell lung cancer to identify local lymphatic spread.
Our objective was to evaluate the feasibility of ultra-low-dose scanning for multislice CT colonography in the detection of colorectal lesions. Twenty-seven patients (14 men, 13 women) with clinical indication for conventional colonoscopy were recruited. Multislice spiral CT (Somatom Plus 4 Volume Zoom, Siemens, Germany) examinations were performed after standard oral colonoscopic preparation and colonic distension with room air. Images were acquired using 2.5-mm collimation, 3.0-mm slice thickness, standard reconstruction kernel, 140 kVp, and 10 mAs. Supine and prone acquisitions were obtained in all patients. Images were analyzed on a workstation by two gastrointestinal radiologists. Conventional colonoscopy was performed on the same day in all patients and represented the standard of reference. Total radiation exposure was also calculated. All colorectal cancers were correctly identified at ...
The purpose of this work is to investigate the possible role of Helical CT defecography in pelvic floor disorders by comparing the results of the investigations with those of conventional defecography. The series analyzed consisted of 90 patients, namely 62 women and 28 men, ranging in age 24-82 years. They were all submitted to conventional defecography, and 18 questionable cases were also studied with Helical CT defecography. The conventional examination was performed during the 4 standard phases of resting, squeezing, Valsalva and straining; it is used a remote-control unit. The parameters for Helical CT defecography were: 5 mm beam collimation, pitch 2, 120 KV, 250 m As and 18-20 degrees gantry inclination to acquire coronal images of the pelvic floor. The rectal ampulla was distended with a bolus of 300 mL nonionic iodinated contrast agent (dilution: 3g/cc). The patient wore a napkin and was seated ...
Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a ...
Aim of this study was to evaluate the sensitivity of virtual colonoscopy (CT colonography) in the identification of colorectal cancer and to define the limitations and the advantages of this imaging modality, as well as indications to the examination. It was examined prospectively 62 symptomatic patients aged 36 to 82 years (28 women and 34 men). All patients underwent both conventional and virtual colonoscopy on the same day; the conventional examination allowed exploration of the entire colon. Conventional colonoscopy identified 89 lesions 3-50 mm in diameter, namely 84 benign and 5 malignant lesions. No lesions were identified in 12 patients. CT colonography identified 52 of the 89 lesions, with 57.1% diagnostic accuracy. They were 11 false positives (82.5% positive predictive value and 52.2% specificity) and 37 false negatives (24.5% negative predictive value and 58.4% sensitivity). Sensitivity was significantly higher ...
We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.) [Deutsch] Die Befunde von drei Patienten mit intrakranieller Tuberkulose (intrakranielle Miliartuberkulose, Meningitis tuberculosa, Neuritis und Tuberkulome) in der Magnetresonanztomographie (MRT) wurden mit der Computertomographie (CT) verglichen. Sowohl die MRT als auch die CT wurden nativ und nach Kontrastmittelgabe durchgefuehrt. Die MRT zeigte sich im Nachweis von Granulomen insbesondere im Bereich des Hirnstamms ...
The accuracy is investigated of both lymphangiography and CT in detecting lymph nodes metastases in 59 patients evaluated preoperatively and subsequently submitted to surgery with selective/systemic pelvic and paraaortic lymphadenectomy. CT accuracy was also investigated in 46 patients with a clinically suspected relapse of ovarian cancer (verified by means of clinical and/or CT follow-up in 36 patients, by laparotomy in 7, by fine-needle biopsy in 1 and by necroscopy in the last 2). In the first group (previously untreated patients) the overall results in the pelvis were, respectively, for lymphangiography and CT: 94.9% vs 89.8% accuracy, 86.6% vs 60% sensitivity, 97.7% vs 100% specificity, and 92.8% vs 100%, 95.5% vs 88% positive and negative predictive values. In the paraaortic region the results were: 89.1% vs 86.5% accuracy, 73.3% vs 66.6% sensitivity, 100% specificity for both techniques, 100% ...
Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager ('Vision', Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, ...
To evaluate the diagnostic accuracy of Fuji computed radiography (FCR) in the detection of interstitial pulmonary infiltrates, FCR life-size images at a pixel size of 0.1 mm were compared with conventional radiographs taken on the same day. Seventeen radiologists assessed the radiographs and FCR images of 56 cases, including 39 cases of various interstitial lung diseases such as interstitial pneumonia, pulmonary abnormalities associated with collagen disease, sarcoidosis, multiple pulmonary metastases, diffuse panbronchiolitis and pulmonary emphysema, and 17 normal controls. All of the pulmonary abnormalities were confirmed by high resolution CT. Observer performance tests were carried out using receiver operating characteristic analysis. In 21 cases of increased pulmonary density revealed by high resolution CT, FCR was significantly superior to conventional radiographs in the detection of reticular or ...
To evaluate the diagnostic accuracy of Fuji computed radiography (FCR) in the detection of interstitial pulmonary infiltrates, FCR life-size images at a pixel size of 0.1 mm were compared with conventional radiographs taken on the same day. Seventeen radiologists assessed the radiographs and FCR images of 56 cases, including 39 cases of various interstitial lung diseases such as interstitial pneumonia, pulmonary abnormalities associated with collagen disease, sarcoidosis, multiple pulmonary metastases, diffuse panbronchiolitis and pulmonary emphysema, and 17 normal controls. All of the pulmonary abnormalities were confirmed by high resolution CT. Observer performance tests were carried out using receiver operating characteristic analysis. In 21 cases of increased pulmonary density revealed by high resolution CT, FCR was significantly superior to conventional radiographs in the detection of reticular or ...
To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI ...
After having discussed the peculiarities of children in X-ray diagnosis the application of the effective as well as the mean equivalent doses as to the determination of the radiation exposure in children is represented. In using computerized tomograms to determine position and extent of an organ the exposure by repeated X-raying was calculated referring to the entrance dose. Entrance dose measurements for all types of X-ray examination in hospitals and ascertainments of the frequency of radiograms in 20 X-ray departments were used to determine per capita and collective doses, resp., in several age groups. Alltogether, the per capita dose of children in the GDR amounts to 30% of that of adults. Conclusions were drawn as to taking measures to further reduction of radiation exposure: (1) Technical measures, such as positioning of patients, shielding of organs, quality assurance; (2) elaboration of ...
Interest in optics for hard X-ray broad-band application is growing. In this paper, we compare the hard X-ray (20-100 keV) reflectivity obtained with an energy-dispersive reflectometer, of a standard commercial gold thin-film with that of a 600 bilayer W/Si X-ray supermirror. The reflectivity of the multilayer is found to agree extraordinarily well with theory (assuming an interface roughness of 4.5 Angstrom), while the agreement for the gold film is less, The overall performance of the supermirror is superior to that of gold, extending the band of reflection at least a factor of 2.8 beyond that of the gold, Various other design options are discussed, and we conclude that continued interest in the X-ray supermirror for broad-band hard X-ray applications is warranted.
A number of diagnostic X-ray units in Poland were subjected to analysis. The air kerma on X-ray tables was measured for the X-ray parameters used routinely during lumbo-sacral spine radiography of standard adult patient. Measurements of air kerma were performed using TLD made of lithium-fluoride. The doses received by patients in different X-ray departments can differ more than two orders of magnitude (from 0.42 mGy up to 72.11 mGy), for the same X-ray examination. The dose can be significantly reduced if fluorescent screens made from components of rare earth are used. (author). 10 refs, 1 fig., 2 tabs.
In spite of the improved imaging techniques currently available, mortality for pancreatic cancer is still high, and pancreatics is often diagnosed only in its advanced stages. The authors investigated the value of different imaging techniques - i.e., US, CT, and ERCP - for an early diagnosis, when a more effective (curative?) treatment can be suggested. Fifty-six cases of pancreatic cancer and 36 cases of chronic pancreatitis were evaluated. The results indicate that ERCP, with the help of statistical methods, is superior to US and CT not only in evaluating early neoplastic or inflammatory lesions, but also for their differential diagnosis. In the letter case, ERCP can sometimes be used as a valid alternative to fine-needle aspiration biopsy.
Study Type - Therapy (case series)Level of Evidence 4 OBJECTIVE To present our experience of retroperitoneoscopic partial adrenalectomy (RPA) for small adrenal tumours, as with modern imaging methods small adrenal lesions are being diagnosed more commonly, and retroperitoneoscopic adrenal surgery for small adrenal tumours (PATIENTS AND METHODS We retrospectively reviewed the records of 389 consecutive retroperitoneoscopic adrenalectomies from September 2005 to December 2008, 88 of which were small adrenal tumours and treated by RPA. Ultrasonography and computed tomography (CT) were used in all patients before RPA, and magnetic resonance imaging or positron emission tomography/CT in some patients. We used RPA for adrenal tumours and total adrenalectomy for adrenal cancer. During the surgery...
Computed tomography (CT) of the neck and mediastinum was performed in 16 patients with renal osteodystrophy. Thirty out of 34 excised parathyroid glands weighing more than 500mg were diagnosed preoperatively (88.2%). Scintigraphy of the neck with _2_0_1TlCl and sup(99m)TcOsub(4-) was also performed in 15 patients. The introduction of subtraction method with a mini-computor in the scintigraphy has remarkably improved the visualization rate of parathyroid glands. Ultrasonic echography (US) of the neck which is able to obtain not only transverse butalso longitudinal imaging was done in 7 patients. It has about same detection rate of the glands with CT. The visualization of enlarged parathyroid glands is valuable not only for localization but also for undeniable evidence of hyperparathyroidism. Also, repeated follow-up examination can determine the effectiveness of conservative treatment. (author).
Field emitter devices are being developed for the gigatron, a high-efficiency, high frequency and high power microwave source. One approach being investigated is porous silicon, where a dense matrix of nanoscopic pores are galvanically etched into a silicon surface. In the present paper pore morphologies were used to characterize these materials. Using of Scanning Electron Microscope (SEM) and Transmission Electron Microscope (TEM) images of both N-type and P-type porous layers, it is found that pores propagate along the <100> crystallographic direction, perpendicular to the surface of (100) silicon. Distinct morphologies were observed systematically near the surface, in the main bulk and near the bottom of N-type (100) silicon lift-off samples. It is seen that the pores are not cylindrical but exhibit more or less approximately square cross sections. X-ray diffraction spectra and electron diffraction patterns verified that bulk porous ...
We present maps of the cosmic large-scale structure around the twelve most distant galaxy clusters from the Massive Cluster Survey (MACS) as traced by the projected surface density of galaxies on the cluster red sequence. Taken with the Suprime-Cam wide-field camera on the Subaru telescope, the images used in this study cover a 27x27 arcmin^2 area around each cluster, corresponding to 10 x 10 Mpc^2 at the median redshift of z = 0.55 of our sample. We directly detect satellite clusters and filaments extending over the full size of our imaging data in the majority of the clusters studied, supporting the picture of mass accretion via infall along filaments suggested by numerical simulations of the growth of clusters and the evolution of large-scale structure. A comparison of the galaxy distribution near the cluster cores with the X-ray surface brightness as observed with Chandra reveals, in several cases, significant offsets ...
The three-dimensional magnetic structure and reversal mechanism of patterned Co/Pt multilayers, were imaged using complementary Lorentz transmission electron microscopy (LTEM) (in-plane component) and magnetic transmission x-ray microscopy (M-TXM) (perpendicular magnetization). The Co/Pt films with perpendicular anisotropy were patterned by ion irradiation through a stencil mask to produce in-plane magnetization in the irradiated regions. The boundaries of the patterns, defined by the transition from out-of-plane to in-plane magnetization, were found to be determined by the stencil mask, whilst the scale of the magnetic reversal by the physical microstructure. The nucleation fields were substantially reduced to 50 Oe for the in-plane regions and 1 kOe for the perpendicular regions, comparing to 4.5 kOe for the as-grown film. The perpendicular reversals were found to always originate at the pattern boundaries.
New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey meter. The results obtained were as follows: 1) By using FCR system the radiation ...
New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey meter. The results obtained were as follows: 1) By using FCR system the radiation ...
Positron emission tomography (PET) is a fully quantitative technology for imaging metabolic pathways and dynamic processes in vivo. Attenuation correction of raw PET data is a prerequisite for quantification and is typically based on separate transmission measurements. In PET/CT attenuation correction, however, is performed routinely based on the available CT transmission data. Recently, combined PET/magnetic resonance (MR) has been proposed as a viable alternative to PET/CT. Current concepts of PET/MRI do not include CT-like transmission sources and, therefore, alternative methods of PET attenuation correction must be found. This article reviews existing approaches to MR-based attenuation correction (MR-AC). Most groups have proposed MR-AC algorithms for brain PET studies and more recently also for torso PET/MR imaging. Most MR-AC strategies require the use of ...
The purpose of this study is to evaluate the radiologic findings of the extraosseous Ewing's sarcoma. Six patients with pathologically confirmed extraosseous Ewing's sarcoma were retrospectively reviewed. Patients included two men and four women with an average age of 21.5 years (age range 9-48 years). Plain radiographs (six patients), magnetic resonance (MR) images (five patients), computed tomographic (CT) scans (three patients) and whole body scintigraphy (two patients) were reviewed and analyzed. Images were evaluated with regard to lesion location, size, margin, muscle or bone involvement and intrinsic imaging characteristics on CT and MRI. The tumors were located in the thigh (three patients), back (two patients) and upper arm (one patient). The tumors ranged in size from 2.3 cm to 7.5 cm (mean, 5.2 cm), were mainly well circumscribed and showed no evidence of calcification ...
TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. ...
NIF target diagnostics are being developed to observe and measure the extreme physics of targets irradiated by the 192-beam laser. The response time of target materials can be on the order of 100ps--the time it takes light to travel 3 cm--temperatures more than 100 times hotter than the surface of the sun, and pressures that exceed 109 atmospheres. Optical and x-ray diagnostics were developed and fielded to observe and record the results of the first 4-beam experiments at NIF. Hard and soft x-ray spectra were measured, and time-integrated and gated x-rayimages of hydrodynamics experiments were recorded. Optical diagnostics recorded backscatter from the target, and VISAR laser velocimetry measurements were taken of laser-shocked target surfaces. Additional diagnostics are being developed and commissioned to observe and diagnose ignition implosions, including various neutron and activation diagnostics. ...
January, 1992, to October, 1995, sixty-four patients with advanced head and neck cancer underwent head and neck reconstructive surgery using myocutaneous or revascularized flaps; in the same period, all patients were consecutively examined with CT and MRI. Myocutaneous flaps were used in 26 patients: 12 flaps were tubular and 14 linear. Revascularized flaps were used in 38 patients: to repair a large defect in 26 patients (14 latissimus dorsi flaps and 12 temporal muscle flaps) and to repair an oral damage in 12 patients (5 revascularized radial and 7 jejunal flaps). CT and MR images of myocutaneous flaps showed the flaps as fatty areas, repairing large surgical defects, hypodense at CT and hyperintense at MRI, with no post-contrast enhancement. The appearance of revascularized flaps at CT and MRI depends on the characteristics of the structure used to repair the surgical defect: ...
January, 1992, to October, 1995, sixty-four patients with advanced head and neck cancer underwent head and neck reconstructive surgery using myocutaneous or revascularized flaps; in the same period, all patients were consecutively examined with CT and MRI. Myocutaneous flaps were used in 26 patients: 12 flaps were tubular and 14 linear. Revascularized flaps were used in 38 patients: to repair a large defect in 26 patients (14 latissimus dorsi flaps and 12 temporal muscle flaps) and to repair an oral damage in 12 patients (5 revascularized radial and 7 jejunal flaps). CT and MR images of myocutaneous flaps showed the flaps as fatty areas, repairing large surgical defects, hypodense at CT and hyperintense at MRI, with no post-contrast enhancement. The appearance of revascularized flaps at CT and MRI depends on the characteristics of the structure used to repair the surgical defect: ...
Computation of effective flow properties of fluids in porous media based on three dimensional (3D) pore structure information has become more successful in the last few years, due to both improvements in the input data and the network models. Computed X-ray microtomography has been successful in 3D pore imaging at micron scale, which is adequate for many sandstones. For other rocks of economic interest, such as chalk and diatomite, submicron resolution is needed in order to resolve the 3D-pore structure. To achieve submicron resolution, a new method of sample serial sectioning and imaging using Focused Ion Beam (FIB) technology has been developed and 3D pore images of the pore system for diatomite and chalk have been obtained. FIB was used in the milling of layers as wide as 50 micrometers and as thin as 100 nanometers by sputtering of atoms from the sample surface. The focused ion beam, consisting of ...
To elucidate the dynamic features of CT scans in peripheral cholangiocarcinoma for the differentiation of this tumor from various primary hepatic neoplasms. Materials were 24 cases of pathologically confirmed peripheral cholangiocarcinoma. Contrast enhancement patterns of central and peripheral portion of the masses were analyzed at three phases including arterial dominant(22), tissue equilibria(24), and postequilibria(9). Other associated CT findings and laboratory data were analyzed. Serum total bilirubin was mostly below 2 mg/dl(22/24), hepatitis B surface antigen was positive in only 9%, serum alphafetoprotein was elevated in 18%, carcinoembryonic antigen in 47%, cancer antigen 19-9 in 60%. In the arterial dominant image(22), 50% of the cases showed peripheral hyperdensity and 50% total hypodensity. In the tissue equilibrial images(24), 63% showed total hypodensity, 25% peripheral hyperdensity, and ...
PurposeThe goal of this study was to clarify the dynamics of tumor oxygen (partial pressure of oxygen, pO2) in SCC VII murine tumors in mice after X-ray...Full Text Available
Microplanar beam radiation therapy has been proposed to treat brain tumors by using a series of rapid exposures to an array of parallel x-ray beams, each beam having uniform microscopic thickness and...Full Text Available
The disulfide-reduced form of bovine ribonuclease A (RNAse A), with the Cys thiols irreversibly blocked, was characterized by small-angle x-ray scattering (SAXS). To help resolve the conflicting...Full Text Available
Radionuclide X-ray fluorescence analysis was used for the determination of iron, calcium, potassium, copper, manganese and zinc in waste water from the production process of citric acid.
Radionuclide X-ray fluorescence analysis was used for the determination of iron, calcium, potassium, copper, manganese and zinc in waste water from the production process of citric acid. (author).
Exact anatomic knowledge about the location of the gonads and the application of corresponding measures of radiation protection are the preconditions for an efficient reduction of the danger of a possible genetic damage as a result of radiation exposition during X-ray examination of the hip joint of newborns. (VJ).
The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K{sub {alpha}} X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K{sub {alpha}} X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be satisfied in order that the ...
The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K_#alpha# X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K_#alpha# X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be satisfied in order that the ...
Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and...Full Text Available
Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.
In this paper, we report a method of precise in situ x-ray scattering measurements on protein solutions using small stationary sample cells. Although reduction in the radiation damage...Full Text Available
An analytic model of magnetic torques applied to an accreting neutron star is employed to evaluate the magnetic dipole moments of x-ray pulsars. A new type of close binary system containing a neutron star is suggested.
Experimental, relative intensities for the components of L X-ray were collected from literature, and atomic-number dependency of L#beta#/L#alpha# has been found. (author).
A photon-induced x-ray fluorescence method allowing the simultaneous determination of iron, copper, zinc, bromine and rubidium in human blood and blood plasma samples is described. The method is reliable and has a good sensitivity for a wide range of elements. (author).
K_#beta#/ K_#alpha# x-ray intensity ratio of chromium were measured in different chromium compounds. The results show the variation of the intensity ratio as a function of the chemical environment around the metal ion. (author)
Bi-U mixed oxides were synthesized by two methods and characterized by X-ray diffraction and X-ray photoelectron spectroscopy. The samples were tested for the catalytic oxidation of carbon monoxide by oxygen. A stepwise redox mechanism consistent with the kinetic results is proposed. (orig.).
We present the X-ray properties of a sample of 17 radio sources observed with the Chandra X-ray Observatory as part of a project aimed at studying the X-ray emission from their radio jets. In this paper, we concentrate on the X-ray properties of the unresolved cores. The sample includes 16 quasars (11 core-dominated and 5 lobe-dominated) in the redshift range z=0.30--1.96, and one low-power radio-galaxy at z=0.064. No diffuse X-ray emission is present around the cores of the quasars, except for the nearby low-power galaxy that has diffuse emission on a scale and with a luminosity consistent with other FRIs. No high-amplitude, short-term variability is detected within the relatively short Chandra exposures. However, 1510-089 shows low-amplitude flux changes with a timescale of $\\sim$25 minutes. The X-ray spectra of the quasar cores are generally well described ...
picture will download the highest resolution version available. M51: X-Rays from the Whirlpool Credit: A. Wilson (UMD) et al., CXC, NASA Explanation: Fresh from yesterday's...
Previous studies have shown that iterative in-line x-ray phase retrieval algorithms may have higher precision than direct retrieval algorithms. This communication compares three iterative phase...Full Text Available
Certain applications are described of radionuclide X-ray fluorescence analysis in the ore dressing industry, in the manufacture of building materials, in metallurgy, pharmacy, in the chemical, photographic and paper industries, in space exploration, in archeology and for measuring the thicknesses of thin layers of coatings. (ES).
The MRI and CT appearances in 48 patients with histologically confirmed benign and malignant pleural abnormalities were compared retrospectively. Abnormal pleural changes were shown in 47 out of the 48 patients by high signal intensity of the pleura in T_2-weighted sequences and in contrast enhanced T_1-weighted sequences on MRI. CT showed abnormalities in 45 out of 48 patients. Delineation of pleural and pulmonary changes by CT was possible in 13 out of 23 cases, and pleural disease from effusions in 15 out of 28 cases. T_2-weighted MRI was successful in 14 out of 23 and 4 out of 28 cases, respectively. T_1-weighted images after contrast were successful in 20 out of 23 and 22 out of 28 cases, respectively. Indications of malignant pleural disease were the presence of mediastinal or circumferential involvement or involvement of the entire pleura, thickness of more than 10 mm and nodular changes. The ...
The preparation by sputtering of artificial metallic superlattices is described, as are the results of x-ray structural determinations. Tunneling and resistivity measurements on these materials are reported.
Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds were studied by electron and proton bombardments. L{sub {gamma}1} X-rays which involve transition of 4d electrons of the valence shell were found to be sensitive to the chemical environment. The L{sub {gamma}1}/L{sub {beta}1} X-ray intensity ratio increased with an increase of the 4d electron occupation of niobium or molybdenum in niobium or molybdenum compounds, showing that the chemical effects can be ascribed to the 4d electron behavior of the metallic atom in its compounds. (orig.).
Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds were studied by electron and proton bombardments. L_#gamma#_1 X-rays which involve transition of 4d electrons of the valence shell were found to be sensitive to the chemical environment. The L_#gamma#_1/L_#beta#_1 X-ray intensity ratio increased with an increase of the 4d electron occupation of niobium or molybdenum in niobium or molybdenum compounds, showing that the chemical effects can be ascribed to the 4d electron behavior of the metallic atom in its compounds. (orig.).
AIM: To assess the impact of the introduction of a computed tomography (CT) imaging protocol for multi-trauma patients on the workload, overall diagnostic yield, and effect on detection of cervical spine injury and pneumothorax. METHOD: Between February 1997 and April 2004, all patients presenting acutely to the Emergency Department (ED) with haemodynamically stable trauma (Abbreviated Injury Scale 3 or more) involving more than two body systems were imaged with a comprehensive pre-set helical CT protocol (including non-contrast head, cervical spine: cranio-cervical and cervico-thoracic junctions; and oral and intravenous contrast-enhanced thoracic, abdomen and pelvis) after initial triage and a standard trauma series of radiographs (chest, lateral C-spine and pelvis). Diagnosis of cervical spine fracture and pneumothorax was noted before and after the CT protocol was carried out ...
Purpose: To evaluate a T_2-weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T_2-weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR_e_f_f/T_E/Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis and representation of the lesions, in 25% MRT was superior. MRT was better for the detection of pulmonary ...
The purpose of this study was to determine the feasibility of virtual endoscopy, named as ''virtual CT laparoscopy'', in the hepatobiliary system prior to laparoscopic cholecystectomy. We applied this technique to 28 patients suspected of having biliary disease. These images were compared and analyzed qualitatively based on visualization of the structures critical to operative cholangiography and surgical findings. Twenty-four patients, who underwent laparoscopic cholecystectomy, were evaluated as follows: the common bile duct and the hepatic duct were adequately visualized in 23 (96%) of the 24 patients, the cystic duct in 21 (88%), the gallbladder opacification in 20 (83%), the liver inferior surface in 20 (83%). Four patients had anatomic variations detected virtual CT laparoscopy and were proven by operative cholangiography and surgical findings. We emphasize that our new technique ...
Sixty-six cases of histologically proven hepatocellular carcinomas (HCC) were studied by MRI. Detectability was better by MRI than by CT, especially in the tumor under 2 cm in diameter. The capsule was detected in all cases of HCC over 3 cm in diameter. The capsule was able to be diagnosed only by dynamic MRI study in some cases. High intensity on the T1-weighted image and iso or low intensity on the T2-weighted image suggested that the nodule was adenomatous hyperplasi (AH) or well differentiated HCC. MRI is concluded to be an essential modality in the diagnosis of HCC. (author).
This case report evaluates X-ray findings in patients with miliary accumulation of mercury observed after parenteral application of metallic mercury in a suizide attempt. There are certain discrepancies between clinical symptoms and the X-ray findings. A clear demonstration of mercury in coronary blood vessels is possible by fluoroscopy.
These proceedings represent papers presented at the Astrophysics Conference in Maryland, USA. The topic of the Conference was the evolution of x-ray binaries and the papers encompass a wide range of subjects on x-ray astronomy. There were one hundred eighteen papers presented at the Conference and out of these three have been abstracted for the Energy Science and Technology database.
The physical foundations and methodology are described of radionuclide X-ray fluorescence analysis. The sources are listed of air, water and soil pollution, and the transfer of impurities into biological materials is described. A detailed description is presented of the sampling of air, soil and biological materials and their preparation for analysis. Greatest attention is devoted to radionuclide X-ray fluorescence analysis of the components of the environment. (ES).
Applications of X-ray fluorescence analysis in coal mining and geology are briefly described based on results published in Czechoslovakia as well as abroad over the past 3 years. Particular attention is paid to the rapid determination of the ash content of coal using portable radionuclide X-ray fluorescence analyzers that are being developed in Czechoslovakia. (author).
The achievement of inner-shell photoionization of Zn-like Pd by means of two exploding foils is described. This resulted in the soft X-ray transition 3d94s2-3d104p at 46 A. It is shown that the photoionization of inner shell electrons in highly stripped ions can lead to X-ray transitions which may be candidates for X-ray lasers under 50 A.
Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).
A brilliant Xray source is proposed for lithography instruments with use of a multi-mirror system. The inverse Compton scattering between the stored electron beam in the storage ring and the stored photon beam in the multi-mirror system, is applied for the X-ray generation. (author)
At the RIKEN-RAL Muon Facility, ?- to ? sticking K? X-rays were observed for the first time taking advantage of the pulsed beam structure. The precision of the present measurements was insufficient to distinguish between theoretical models, however the observed K?/K? X-ray intensity ratio tends to be smaller than most of these theoretical predictions.
Based on a literature study an actual summary of the risk-utility problems in X-ray diagnosis is outlined due to the Recommendations of the International Commission for Radiation Protection (ICRP publication 26/1977). Papers demonstrating quantitative assessment of the somatic and genetical risk in X-ray examination are preferably cited and evaluated. It is concluded that the somatic and genetical risk is low in diagnostic ratiology. However, it must not be neglected and has always to be compared to the utility of an examination as well as to other risks of the examination. (author).
The basic principles of determination of the ash content of coal by the title methods are outlined. A brief technical characteristic of the ash meters and radionuclide X-ray fluorescence analyzers manufactured by the PAR company is presented. (Z.S.). 4 figs., 7 refs.
Determination of Mn, Fe, Ni, Cu, Zn, and Pb in human soft tissues by radionuclide X-ray fluorescence analysis (using "2"3"8Pu and "1"0"9Cd sources) is described. The results of multielement XRS analysis of selected human tissues are tabulated. They are in good agreement with the literature data. It is concluded that X-ray fluorescence technique is a suitable method for trace element determination. (author).
Stylized numerical models of the tooth are usually employed in qualification procedure related to Electronic Paramagnetic Resonance in long-term accidental contamination dose reconstruction. In this work a voxel model was developed from the microCTimage data set of a human non contaminated molar tooth. A stylized model, reproducing the characteristics of the voxel model, was also created in order to investigate the level of accuracy that can be obtained in this kind of study.
The intrasphenoid form of basal cephalocele is uncommon. We describe the clinical, CT and MRI findings in two cases presenting in middle age with persistent cerebrospinal fluid rhinorrhoea. Emphasis is placed upon the imaging findings which aid in discrimination of intrasphenoidal cephalocele from more common causes of a sphenoid sinus mass. (orig.)
The purpose of this study was to correlate MR imaging findings with pathology in experimental hyperoxia-induced acute lung injury, which has similar pathology to diffuse alveolar damage (DAD). Seventeen Yorkshire pigs were studied. These animals were exposed to more than 80% oxygen for 24, 48, 72, and 96 hours in a sealed cage. The lungs were removed and inflated with air infused through the trachea, and then examined by both MRI and high-resolution CT (HRCT). T1-weighted spin-echo (T1WSE), T2-weighted fast (T2WFSE), and half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequences were performed. Severity in MR findings and signal-to-noise ratios (SNR) on MR images were well correlated with pathological scores. CT values were also correlated well with pathologic scores. Abnormal SNR values were obtained from a pathological score of 5, whereas abnormal CT values were ...
The purpose was to evaluate low-dose CT colonography without cathartic cleansing in terms of image quality, polyp visualization and patient acceptance. Sixty-one patients scheduled for colonoscopy started a low-fiber diet, lactulose and amidotrizoic-acid for fecal tagging 2 days prior to the CT scan (standard dose, 5.8-8.2 mSv). The original raw data of 51 patients were modified and reconstructed at simulated 2.3 and 0.7 mSv levels. Two observers evaluated the standard dose scan regarding image quality and polyps. A third evaluated the presence of polyps at all three mSv levels in a blinded prospective way. All observers were blinded to the reference standard: colonoscopy. At three times patients were given questionnaires relating to their experiences and preference. Image quality was sufficient in all patients, but significantly lower in the cecum, sigmoid and rectum. The two ...
Forty-four patients with small cell carcinoma of the bronchus underwent CT and MR studies of the brain to detect cerebral metastases. All patients were studied with contrast-enhanced CT scans, short (T1-weighted) and long (T2-weighted), spin-echo (SE) and FLASH 90 grades sequences were also obtained. A quantitative comparison of the results was carried out to assess the sensitivity of the different techniques in the detection of brain metastases according to lesion diameter. Metastases were identified in 19/44 patients (43%). All techniques detected the lesions >2 cm; of the metastases <2 cm, 63/124 (51%) were detected only by GdDTPA SE-T1 and FLASH sequences and 11 more (9%) only by Gd-DTPA SE-T1 scans. All the lesions identified oh enhanced CT scans or on T2-weighted images were easily detected by Gd-DTPA scans. CT sensitivity was higher than that of pre-contrast SE-T1 and ...
T{sub 2} weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T{sub E}=90 ms, T{sub R}=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good ...
Purpose: In the present study the reduction of artifacts using an extended CT scale technique was examined in 5 vitallium and 5 titanium-aluminium-vanadium tumor prostheses. Methods: 5 titanium-aluminium-vanadium and 5 vitallium distal femur Mutars {sup trademark} tumor prostheses (Mutars {sup trademark} - Modular Universal Tumor And Revision System) were implanted in 10 human femur specimens. 110 artifical drill hole lesions of 1 mm, 2 mm, 3 mm, 5 mm and 8 mm diameter were placed in the bone around the hexagonal stem of the tumor prosthesis and furthermore in the proximal part of the femur. All specimens were examined using conventional CT and an extended CT scale technique in a slice thickness of 3 mm. Results: In the proximal part of the femur all drill holes could be detected using 3 mm slices, no artefacts were observed. Along the hexagonal stem smooth lines arising from each hexagonal plane could be observed. This ...
Focused ion beam (FIB) microscopes have become well-established in the semiconductor industry during the past decade, and are rapidly gaining attention in the field of materials science, both as a tool for producing site specific, parallel sided transmission electron microscope (TEM) specimens and as stand alone specimen preparation and imaging systems. FIB secondary electron imaging (SEI) of nickel-based alloys, such as commercially produced Alloy 600 (approximately Ni 15Cr 10Fe 0.5C), has been demonstrated to show a high degree of sensitivity to the presence of deformation in the alloy, and FIB secondary ion imaging (SII) is particularly useful for identifying the presence of grain boundary corrosion, as secondary ion yields from metallic specimens can increase by three orders of magnitude in the presence of oxygen. This 'oxygen enhanced yield', makes FIB SII ideal for detection of corrosion at grain boundaries down to ...
A method has been developed to optimize the energy resolution of a horizontally focusing monochromator. The method consists of determining the optimum radius of curvature of the cylindrically bent monochromator crystal by minimizing the total diffracted X-ray flux measured through an X-ray absorption foil. When measured at an absorption edge a global minimum can be identified, which corresponds to the minimum energy band accepted along the entire length of the crystal. Experimental verification of this method has been validated by comparing X-ray fluorescent scans taken for a series of crystal curvatures and by directly measuring the X-ray beam profiles at the corresponding points. The actual optical configuration and asymmetric-cut parameter of the focusing monochromator on beamline X4C at the National Synchrotron Light Source are modeled and ray tracing simulations of the optical system are compared ...
A miniature x-ray source utilizing a hot filament cathode. The source has a millimeter scale size and is capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature source consists of a compact vacuum tube assembly containing the hot filament cathode, an anode, a high voltage feedthru for delivering high voltage to the cathode, a getter for maintaining high vacuum, a connector for initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is fabricated from highly x-ray transparent materials, such as sapphire, diamond, or boron nitride.
Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of lifetime of the charge carriers with the increase of X-ray radiation dose.
An x-ray diffraction technique for determining thin-film thickness is presented which should prove to be a valuable alternative to the array of spectroscopies (Rutherford backscattering spectrometry, Auger electron spectroscopy, etc.) currently favored for these measurements. Some of the virtues of this x-ray diffraction approach are its nondestructive nature, fast data acquisition rate (enabling in situ observations), thickness resolution better than 5 nm, and conventional equipment requirements. Results are shown for Pd/sub 2/Si thin films grown during isothermal annealing of Pd coatings (100 nm) on Si at 200 /sup 0/C for various amounts of time. A comparison of these x-ray measurements with Rutherford backscattering spectrometry data taken from the same specimens is used to demonstrate the validity of the x-ray technique.
We propose and analyze a novel regenerative amplifier free electron laser (FEL) to produce fully coherent x-ray pulses. The method makes use of narrow-bandwidth Bragg crystals to form an x-ray feedback loop around a relatively short undulator. Self-amplified spontaneous emission (SASE) from the leading electron bunch in a bunch train is spectrally filtered by the Bragg reflectors and is brought back to the beginning of the undulator to interact repeatedly with subsequent bunches in the bunch train. The FEL interaction with these short bunches not only amplifies the radiation intensity but also broadens its spectrum, allowing for effective transmission of the x-rays outside the crystal bandwidth. The spectral brightness of these x-ray pulses is about two to three orders of magnitude higher than that from a single-pass SASE FEL.
The authors carried out a retrospective study on 4 years' work on a series of patients with proved active tuberculosis examined in the Departments of Bronchopneumology and Infectious Disease of the Arezzo Civil Hospital. The population was heterogenerous from the immunologic viewpoint. This paper compared the effectiveness of Computed Tomography (CT) with that of conventional chest radiography (CR) in the diagnosis and prognosis of tuberculosis. All patients underwent chest CR in double projection and conventional CT studies of the chest; 16 patients were also submitted to high resolution CT (HRCT). Consolidation was the most frequent parenchymal lesion in immunocompetent patients; it was often associated with cavitation, with no clear topographic prevalence in the upper lobes. Pleural effusion, as the only sign of disease and with empyema features, was found in 10 immunocompetent patients. No predominant pattern was found ...
Purpose: To quantify left ventricular function derived from retrospectively ECG-gated multislice spiral CT (MSCT) data sets in comparison to MRI. Materials and Methods: In 16 patients (14 males, 2 females, mean age 56.8 #+-# 11.5 years), retrospectively ECG-gated MSCT angiography of the coronary arteries and breath-hold steady state free precession cine MRI were performed. From MSCT data-sets, 20 axial image series were reconstructed every 5% of the RR interval. Multiplanar images were reformatted in the short axis orientation from axial images. End-systolic and end-diastolic images were selected. From these images end-systolic volume (ESV), end-diastolic volume (EDV) and stroke volume (SV) as well as the ejection fraction (EF) and myocardial mass (MM) were determined using the Simpson's method and compared with MRI. Furthermore, image ...
Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database ...
The {ital L}{sub 2}-{ital L}{sub 3} Coster-Kronig transition probability ({ital f}{sub 23}) in Tm was measured by multiparameter {ital K} versus {ital L} x-ray coincidence techniques. The Tm xrays were obtained from a radioactive source of {sup 169}Yb and were detected with cooled germanium and silicon detectors of high-energy resolution. Corrections were applied for the contribution of {ital K}{alpha}{sub 1} xrays to the {ital K}{alpha}{sub 2} x-ray peak and for the contribution of unresolved {ital L}{eta} xrays to the {ital L}{alpha}{sub 1,2} x-ray peak. The contribution of {ital K}{alpha}{sub 1} xrays to the {ital K}{alpha}{sub 2} x-ray peak was determined solely from the results of the coincidence measurements using a method of ...
The {ital L}{sub 2}-{ital L}{sub 3} Coster-Kronig transition probability ({ital f}{sub 23}) in Tm was measured by multiparameter {ital K} versus {ital L} x-ray coincidence techniques. The Tm xrays were obtained from a radioactive source of {sup 169}Yb and were detected with cooled germanium and silicon detectors of high-energy resolution. Corrections were applied for the contribution of {ital K}{alpha}{sub 1} xrays to the {ital K}{alpha}{sub 2} x-ray peak and for the contribution of unresolved {ital L}{eta} xrays to the {ital L}{alpha}{sub 1,2} x-ray peak. The contribution of {ital K}{alpha}{sub 1} xrays to the {ital K}{alpha}{sub 2} x-ray peak was determined solely from the results of the coincidence measurements using a method of ...
For the evaluation of diseases of salivary origin, ultrasound and/or sialography is recommended instead of MRI. In cases of salivary tumor, ultrasound may be helpful in delineating superficial tumors. For small tumors no further imaging is needed. When dealing with a large tumor or a tumor in the deep lobe of the parotid gland, MRI is the preferred imaging method. Not only does MRI provide a large variety of soft tissue signal differences, but also the multiplanar facilities are helpful in delineating the extent of the tumor, whether located in the submandibular, sublingual, or parotid gland. Skull base invasion is often well seen by MRI. Subtle changes may be missed and in those cases CT is recommended to exclude or prove destruction of the skull base. For the evaluation of patients presenting with a recurrent pleomorphic adenoma, MRI is recommended in all patients. MRI delineates the extent and number of recurrent tumors ...
Purpose: To assess the prevalence, significance and practical value of two recently described CT signs of instable aneurysm: the crescent sign and the periluminal halo (a low-attenuating internal layer of the thrombus around the patent lumen). Material and methods: Among the CT examination performed in the last 5 years, they retrospectively selected the nonruptured aneurysms with a diameter exceeding 4 cm (no. = 93 average diameter 5.1 cm, unenhanced images in 28 cases and enhanced in 84) and the ruptured aneurysms (no. = 16, average diameter 6.7 cm, unenhanced images in 9 cases and enhanced in 9). They studied the prevalence of the crescent and halo sing, their relationship with the aneurysm diameter, and the effect of contrast enhancement. Results: The crescent sign was identified with a statistically significant prevalence in ruptured ( 37.5 % or cases) over asymptomatic aneurysms (5.5 %); the halo ...
In the case of injuries of the ankle joint, an imaging technique is expected to reveal the state of the bones, ligaments, and articular cartilage. Irrespective of novel imaging techniques, a plain radiography will be made in order to obtain a first picture of the injury. Examples are given, showing that further orientation along the Lauge-Hansen classification scheme of this type of injury helps to completely ascertain the damage to the Articulatio talocruralis. Further examinations applying specific methods such as arthrography will detect possible, isolated syndesmosis ruptures; lesions of the ligaments can also be directly detected by CT or MRT. The articular cartilage and its lesions can be visualized by a combination of CT and arthrography, but are better shown by the completely non-invasive MRT. This latter method also gives insight into pathological processes with the bone. It allows to detect ...
Described is the diagnosis for the cancer extension of cholangiocarcinoma by various imaging techniques and processes to support the current surgical procedure based on preoperative biliary drainage. The cancer tends to locally extend horizontally and/or vertically and its diagnosis is important for surgical indication. For the indication, multi-detector raw CT (MDCT) and MR cholangio-pancreatography (MRCP) are useful and particularly, the former can give multi-phase (arterial, portal and delayed) images to reconstruct multiplanar (MPR) and CT angiographic 3D images, which have made the previous invasive examinations like angiography and percutaneous transportal contrasting unnecessary. MDCT and MRCP can almost complete the diagnosis of the extension. The operative procedure is decided dependently on the site of the lesion, and of which diagnosis, whether it is hepatic hilar/on ...
The interaction of intense, sub-picosecond laser pulses with solid targets produces intense picosecond x-ray pulses. With focused laser pulses of several 10 {sup 18} W/cm{sup 2}, He-like and H-like line radiation from targets such as aluminum and silicon has been produced. The energy conversion efficiency from the laser pulse energy to the 1--2 keV line x-rays is nearly one percent. The duration of the line x-ray radiation is of the order of ten picoseconds, although this may be an upper estimate because of the temporal resolution of the x-ray streak camera. The spatial extent of the x-ray source region is only slightly larger than the laser focal spot, or about 10 {mu}m in diameter. With these characteristics, such x-ray sources emit an intensity of nearly 10{sup 14} W/cm{sup 2}. Experiments and modeling which led to the above conclusions will be discussed.
Oxide superconducting thin films were irradiated with X-rays and ultra-violet (UV) light, and induced radiation effects on electrical and chemical properties were examined by transport measurement, X-ray diffraction analysis (XRD), diamagnetization measurement and X-ray photoemission spectroscopy (XPS). After irradiation for ErBa_2Cu_3O_x films with X-rays emitted from a Rh tube for 100 hours, superconductivity was remarkably damaged, destroying the zero-resistance state. The UV-light irradiation for Bi_2Sr_2CaCu_2O_x films was performed in He gas of about 500 Pa with a low pressure mercury lamp. The superconductivity was gradually degraded with the UV irradiation time up to 70 minutes. In both cases, adequate oxygen-annealing treatments restored superconductivity. The X-ray photoemission spectra showed that the mean Cu valence of the films was decreased approximately from +2 to +1 ...
The peak flux relationship between hard X-rays and microwaves from solar flares is studied using about 400 events simultaneously recorded with the hard X-ray burst spectrometer on the SMM satellite and the Nobeyama 17 GHz radiometer. The data indicate that the hard X-ray and microwave peak fluxes correlate best for X-ray energies of less than about 80 keV for impulsive flares and greater than about 360 keV for extended flares. By postulating that electrons responsible for microwave emission at 17 GHz are those emitting hard X-rays at these photon energies, it is concluded that: (1) in impulsive flares, microwaves at about 20 GHz are emitted mainly by electrons of less than about 200 keV from a layer through which the electrons stream down into the thick-target hard X-ray source; and (2) in extended flares, microwaves are emitted mainly by MeV electrons trapped ...
We report the detection of X-ray pulsations with a period of ?315.87 ms from the 2009 XMM-Newton observation for the radio-quiet ?-ray pulsar, LAT PSR J0007+7303, centered in the supernova remnant CTA 1. The detected pulsed period is consistent with the ?-ray periodicity at the same epoch found with the Fermi Gamma-ray Space Telescope. The broader sinusoidal structure in the folded light curve of the X-ray emission is dissimilar to that of the ?-ray emission, and the phase of the peak is about 0.5 shifting from the peak in the ?-ray bands, indicating that the main component of the X-rays originates from different sites of the pulsar. We conclude that the main component of the X-ray pulsation is contributed by the thermal emission from the neutron star. Although with a significantly different characteristic age, PSR J0007+7303 is similar to Geminga in emission properties of X-rays ...
Six illitized samples from drillhole OL-KR12 in Olkiluoto were analyzed by helium gas methods for their diffusion coefficient, permeability and porosity. The diffusion coefficients measured varied in the range 2.1 x 10-10 - 3.5 x 10-8 m2/s, permeabilities in the range 6 x 10-21 - 5.8 x 10-16 m2, and porosities in the range 0.2 6.2%. Variations observed in these quantities were concluded to arise from the heterogeneous structure of the sample rock. A 4 mm x 4 mm x 4 mm subsample was sawed from each of the six samples for structural analysis by x-ray microtomography. The three-dimensional structure of tomographic reconstructions, and thereby that of the samples themselves, was analyzed visually, which confirmed their heterogeneity. Samples represent altered rock whose structure and thereby transport properties vary significantly depending on the local alteration history of the rock. (orig.)
Recent wide-field imaging observations of the X-ray luminous cluster RDCSJ1252.9-2927 at z=1.24 uncovered several galaxy groups that appear to be embedded in filamentary structure extending from the cluster core. We make a spectroscopic study of the galaxies in these groups using GMOS on Gemini-South and FORS2 on VLT with the aim of determining if these galaxies are physically associated to the cluster. We find that three groups contain galaxies at the cluster redshift and that they are probably bound to the cluster. This is the first confirmation of filamentary structure as traced by galaxy groups at z>1. We then use several spectral features in the FORS2 spectra to determine the star formation histories of group galaxies. We find a population of relatively red star-forming galaxies in the groups that are absent from the cluster core. While similarly red star forming galaxies can also be found in the field, the average strength of the hd ...
The optical properties and microstructure of germanium (Ge) films, prepared by ion-assisted deposition (IAD) process, were investigated. The Ge films were deposited on sapphire and silicon substrates, with and without simultaneous Ar+ bombardment. Higher index films, with a refractive index 7.7% larger than that of the single crystalline Ge wafer, were obtained with the IAD process. The density of the IAD film could be 1.5% greater than that of the e-beam film. The results of the heat treatment indicated that the optical and structural properties of the IAD films were more stable. Ge nano-crystallites could be observed under high ion power density, which induced a crystalline structure in the Ge thin films. The average size of the nano-crystallites, as determined from both the X-ray diffraction data and the transmission electron microscopy images, showed that no systematic change had occurred. The results presented in this work suggest that the ...
Focused ion beam (FIB) irradiation of a thin Ni_2Si layer deposited on a Si substrate was carried out and studied using an in-situ transmission electron microscope (in-situ TEM). Square areas on sides of 4 by 4 and 9 by 9 microm were patterned at room temperature with a 25 keV Ga"+-FIB attached to the TEM. The structural changes of the films indicate a uniform milling, sputtering of the Ni_2Si layer and the damage introducing to the Si substrate. Annealing at 673 K results in the change of the Ni_2Si layer into an epitaxial NiSi_2 layer outside the FIB irradiated area, but several precipitates appear around the treated area. Precipitates was analyzed by energy dispersive X-ray spectroscopy (EDS). Larger amount of Ni than the surrounding matrix was found in precipitates. Selected area diffraction (SAD) patterns of the precipitates and the corresponding dark field images imply the formation of a Ni rich silicide. The relation between the FIB tail ...
One of the most interesting discoveries of the X-ray Telescope and EUV Imaging Spectrometer (EIS) on board the Hinode solar observatory is the presence of persistent high temperature high speed outflows from the edges of active regions. Measurements by EIS indicate that the outflows reach velocities of 50 km/s with spectral line asymmetries approaching 200 km/s. It has been suggested that these outflows may lie on open field lines that connect to the heliosphere, and that they could potentially be a significant source of the slow speed solar wind. A direct link has been difficult to establish, however. In this letter, we use EIS measurements of spectral line intensities that are sensitive to changes in the relative abundance of Si and S as a result of the first ionization potential (FIP) effect, to measure the chemical composition in the outflow regions of AR 10978 over a period of 5 days in December 2007. We find that Si is always enhanced ...
In this study, Cu{sub 2}O/Cu composite particles were synthesized using an innovative chemical reduction method without any template and surfactant. X-ray diffraction (XRD) analysis revealed that the product mainly consisted of Cu{sub 2}O phase coexisting with a Cu phase. FE-SEM images showed that the octahedral shaped particles were Cu{sub 2}O. The electrochemical performance of the Cu{sub 2}O/Cu particles was investigated with regards to the working electrode material in alkaline solution. The particles had a maximum discharge capacity of 222.9 mAh/g at a discharge current density of 60 mA/g and a high value of 109.1 mAh/g after 50 charge-discharge cycles. Cyclic voltammetry revealed that the reaction between Cu{sub 2}O and Cu is the major electrochemical reaction during the charging and discharging process. Electrochemical impedance spectroscopy revealed that the formation of Cu{sub 2}O on the surface of Cu particles increased the contact ...
A Digital X-rayimaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS method): A simple ...
The relationship between serum PG I, PG II levels and extent of atrophic gastritis was examined. The subjects were 64 patients (male: 32, female: 32, 51.9 years old on average) with established diagnosis of either atrophic gastritis or normal. In the X-ray gastric examination, Fuji Computed Radiography (FCR) was used to obtain clear-cut images of the gastric area. Concerning the serum PG I level, patients in the group with atrophic gastritis showed lower levels than those of the people in the group with no atrophic change, but the variation was wide, and no definite tendency was seen in the relationship between the atrophic change and the serum PG I levels. Concerning the serum PG II level, as the atrophic change progresses, the serum PG II level tended to increase gradually. A significant reduction in the PG I/II ratio was seen in the group with atrophic changes (p<0.01) in comparison with the group with no atrophic changes, and the PG I/II ...
The relationship between serum PG I, PG II levels and extent of atrophic gastritis was examined. The subjects were 64 patients (male: 32, female: 32, 51.9 years old on average) with established diagnosis of either atrophic gastritis or normal. In the X-ray gastric examination, Fuji Computed Radiography (FCR) was used to obtain clear-cut images of the gastric area. Concerning the serum PG I level, patients in the group with atrophic gastritis showed lower levels than those of the people in the group with no atrophic change, but the variation was wide, and no definite tendency was seen in the relationship between the atrophic change and the serum PG I levels. Concerning the serum PG II level, as the atrophic change progresses, the serum PG II level tended to increase gradually. A significant reduction in the PG I/II ratio was seen in the group with atrophic changes (p<0.01) in comparison with the group with no atrophic changes, and the PG I/II ...
Capacitance dispersion on the fractal carbon electrode with edge and basal orientations was investigated using atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS), and a.c.-impedance spectroscopy. For this purpose, four types of as-received pyrolytic graphite electrode, as-received, mechanically polished, and as-activated glassy carbon electrodes were prepared with different surface irregularities and amounts of edge orientations. The apparent self-similar fractal dimensions of the carbon electrodes were determined from the analyses of AFM images based upon triangulation method. The amounts of edge orientations on the surface of the carbon electrodes were qualitatively estimated from the XPS analysis of surface acidic functional groups that were preferably formed on the edge planes by the heat treatment of the carbon electrodes. The values of the constant phase element exponent {alpha} determined from the apparent self-similar ...
X-ray photoelectron spectroscopy (XPS) and transmission electron microscopy (TEM) have been conducted on a new fuel cell electrocatalytic material based on a highly porous carbonized polyacrylonitrile (PAN) microcellular foam with very low platinum loading ({approximately}13 to 23 {micro}g/cm{sup 2}). TEM images of this material clearly show the existence of nanometer size platinum particles which are homogeneously distributed in the highly porous carbonized PAN matrix. An XPS study of Pt-loaded PAN indicates that C 1s, O 1s, and N 1s peaks shift to lower binding energies, compared to virgin PAN. It was concluded that special metal-support interaction exists, through the formation of a charge-transfer complex between platinum and pyridine-type nitrogen atoms of PAN support. This interaction leads to the enhancement of the catalytic activity, and the improvement of the long-time stability of this electrocatalyst.
We report the discovery of a bow shock around the high-mass X-ray binary (HMXB) 4U 1907+09 using the Spitzer Space Telescope 24 $\\mu$m data (after Vela X-1 the second example of bow shocks associated with HMXBs). The detection of the bow shock implies that 4U 1907+09 is moving through the space with a high (supersonic) peculiar velocity. To confirm the runaway nature of 4U 1907+09, we measured its proper motion, which for an adopted distance to the system of 4 kpc corresponds to a peculiar transverse velocity of $\\simeq 160 \\pm 115$ km/s, meaning that 4U 1907+09 is indeed a runaway system and supporting the general belief that most of HMXBs possess high space velocities. The direction of motion of 4U 1907+09 inferred from the proper motion measurement is consistent with the orientation of the symmetry axis of the bow shock, and shows that the HMXB is running away from the Galactic plane. We also present the Spitzer images of the bow shock ...
Magnetic resonance imaging has proven an invaluable method in the diagnosis of joint diseases associated with osteonecrotic, inflammatory, traumatic and degenerative processes. At the clinical level, it has an important role in decisions about the method of treatment and evaluations of the therapeutic success. When the merits of MRT are balanced against those of conventional radiography including tomography and CT, which both ensure better spatial resolution in the visualisation of cortical and spongy bone structures, it becomes quite evident that MRT must not be regarded as an alternative method of imaging but as one that can be used additionally to obtain the most information for the diagnosis of arthropathy. The question as to whether new pulse sequences (snap shots) or invasive techniques like intra-articular injection of paramagnetic substances (MR arthrography) are likely to become routine procedures in the detection ...
Herein we present an impact of diagnosis by enhanced multidetector-row computed tomography and magnetic resonance imaging for extrahepatic cholangiocarcinoma (ECC). Although the diagnosis against the longitudinal stromal extension and surrounding tissue invasion of ECC by multi detector row CT (MDCT) and MRI was very strict, we could not detect any superficial mucosal spread (SMS). Furthermore, the diagnosis of lymphnode metastasis by MDCT/MRI was miserable. We believe that misdiagnosis of SMS is permissible since positive mucosal but not stromal surgical margin was not a significant factor influencing the postoperative prognosis. However, further advances in imaging diagnosis for ECC is needed. (author)
Objective To report the clinical response to image-guided percutaneous cryotherapy (IPC) for the palliative management of localized metastases in patients with gynecologic malignancies. Methods Institutional review board approval and patient consent were obtained. Gynecologic oncology patients were identified from our institution's cryotherapy database from August 2003 to August 2007. Cryotherapy was performed with 2.4?mm diameter probes (Endocare, Irvine, CA) with ultrasound or computerized tomography (CT) guidance under conscious sedation and local anesthesia. Follow-up was conducted by imaging studies and clinical encounters, using Response Evaluation Criteria in Solid Tumors (RECIST criteria). Results Twenty-eight ablation sessions were performed for 41 metastatic foci in 15 patients w...
The objective of this study was to develop full body CAD geometry of a seated 50th percentile male. Model development was based on medical image data acquired for this study, in conjunction with extensive data from the open literature. An individual (height, 174.9?cm, weight, 78.6???0.77?kg, and age 26?years) was enrolled in the study for a period of 4?months. 72 scans across three imaging modalities (CT, MRI, and upright MRI) were collected. The whole-body dataset contains 15,622 images. Over 300 individual components representing human anatomy were generated through segmentation. While the enrolled individual served as a template, segmented data were verified against, or augmented with, data from over 75 literature sources on the average morphology of the human body. Non-Uniform Rational...
A method of reconstructing three-dimensional, in vivo dose distributions delivered by intensity-modulated radiotherapy (IMRT) is presented. A proof-of-principle experiment is described where an inverse-planned IMRT treatment is delivered to an anthropomorphic phantom. The exact position of the phantom at the time of treatment is measured by acquiring megavoltage CT data with the treatment beam and a research prototype, flat-panel, electronic portal imaging device. Immediately following CTimaging, the planned IMRT beams are delivered using the multiple-static field technique. The delivered fluence is sampled using the same detector as for the CT data. The signal measured by the portal imaging device is converted to primary fluence using an iterative phantom-scatter estimation technique. This primary fluence is back-projected through the previously acquired ...
Two cases of focal nodular hyperplasia (FNH), in which ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MR) studies detected an atypical hemorrhagic pattern associated with an intrahepatic arterio venous malformation (AVM) around the growths, are presented. In both cases, histology demonstrated a very early regenerative stage and necrotic-hemorrhagic areas within the lesions. In these cases, the analysis of radiological findings, surgical specimens and histology seemed to confirm the pathogenetic hypothesis suggested by Wanless: in normal liver parenchyma, a ``blood steal`` phenomenon due to congenital or acquired intrahepatic AVM could cause ischemic damage, appearing as a hemorrhagic necrotic area, the extent of which depends on the degree of residual portal supply. (orig.)
Abstract Crouzon syndrome is characterized by premature fusion of sutures and synchondroses. Recently, the first mouse model of the syndrome was generated, having the mutation Cys342Tyr in Fgfr2c, equivalent to the most common human Crouzon/Pfeiffer syndrome mutation. In this study, a set of micro-computed tomography (CT) scannings of the skulls of wild-type mice and Crouzon mice were analysed with respect to the dysmorphology caused by Crouzon syndrome. A computational craniofacial atlas was built automatically from the set of wild-type mouse micro-CT volumes using (1) affine and (2) non-rigid image registration. Subsequently, the atlas was deformed to match each subject from the two groups of mice. The accuracy of these registrations was measured by a comparison of manually placed landma...
Purpose: To evaluate a T{sub 2}-weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T{sub 2}-weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR{sub eff}/T{sub E}/Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis and representation of the lesions, in 25% MRT was superior. MRT was better for the ...
The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the {gamma}-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10{sup 6}n/cm{sup 2}s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/{gamma} ratio {approx} 10{sup 6}n/cm{sup 2}mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame grabber and a computer. ...
The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the #gamma#-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10"6n/cm"2s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/#gamma# ratio #approx# 10"6n/cm"2mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame grabber and a computer. The device composed ...
Purpose: To describe the technique of DE MDCT colonoscopy and to assess its feasibility. Materials and Methods: 8 patients were scanned with DSCT with a DE scan protocol and dose modulation software. Analysis was performed using dedicated DE software. Prone non-contrast images and DE supine images after contrast injection were obtained. Results: DE colonoscopic images were successfully obtained in 7 patients, but the FOV did not cover all colonic segments in 1 patient, thus resulting in a technical success rate was 87.5%. Streak artifacts were present in the pelvic region in 2 patients. Virtual unenhanced images and iodine map images were obtained for all patients. In 1 patient a polypoid non-enhancing structure was noted on the iodine map, and conventional colonoscopy revealed impacted stool. Enhancing rectal cancer in 1 patient was correctly shown on the iodine map. Iodine maps ...
Purpose: To develop an accurate, fast, and robust algorithm for registering portal and computed tomographic (CT) images for radiotherapy using a combination of sparse and dense field data that complement each other. Methods and Materials: Gradient Feature Weighted Minimax (GFW Minimax) method was developed to register multiple portal images to three-dimensional CTimages. Its performance was compared with that of three others: Minimax, Mutual Information, and Gilhuijs' method. Phantom and prostate cancer patient images were used. Effects of registration errors on tumor control probability (TCP) and normal tissue complication probability (NTCP) were investigated as a relative measure. Results: Registration of four portals to CTs resulted in 30% lower error when compared with registration with two portals. Computation time increased by nearly 50%. GFW Minimax ...
The purpose of this study is to develop a geometrically accurate imaging protocol at 3 T magnetic resonance imaging (MRI) for stereotactic radiosurgery (SRS) treatment planning. In order to achieve this purpose, a methodology is developed to investigate the geometric accuracy and stability of 3 T MRI for SRS in phantom and patient evaluations. Forty patients were enrolled on a prospective clinical trial. After frame placement prior to SRS, each patient underwent 3 T MRI after 1.5 T MRI and CT. MR imaging protocols included a T1-weighted gradient echo sequence and a T2-weighted spin echo sequence. Phantom imaging was performed on 3 T prior to patient imaging using the same set-up and imaging protocols. Geometric accuracy in patients and phantoms yielded comparable results for external fiducial reference deviations and internal landmarks ...
Computed tomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computed tomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. Future applications of ...
Computed tomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computed tomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. Future applications of ...
Full text: Measurement of K_#beta# to K_#alpha# x-ray intensity ratios are important not only in the field of atomic physics, radiation physics and medical physics, but also to test the validity of assumptions made in the theoretical prediction. The intensity ratios can also give information on the effect of physical and chemical environment of the element in the compound. Many investigators have adopted a single and double reflection geometries to measure the K_#beta# to K_#alpha# xray intensity ratios to understand the effect of physical and chemical environment on x-ray fluorescence. The targets are excited by a radioactive source of having activity of the order 100 MBq. in order to carry out accurate measurement K_#beta# to K_#alpha# x-ray intensity ratios, we have develop 2#pi# geometrical configuration method : placing a target right on the surface of the detector facing the ...
The purpose of this study was to test a large sample of different coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in 64-slice multidetector-row computed tomography (MDCT) in vitro and to provide a catalogue of currently used coronary artery stents when imaged with state-of the-art MDCT. We examined 68 different coronary artery stents (57 stainless steel, four cobalt-chromium, one cobalt-alloy, two nitinol, four tantalum) in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70). Stents were imaged in axial orientation with standard parameters: 32x0.6 collimation, pitch 0.24, 680 mAs, 120 kV, rotation time 0.37 s. Four different image reconstructions were obtained with varying convolution kernels and section thicknesses: (1) soft, 0.6 mm, ...
Conventional radiography has been the accepted nondestructive testing (NDT) method used for many years to either ''accent'' or ''reject'' a field weld in the pipeline industry. However, conventional radiography requires the expense of film, developing chemicals, and manpower for film development. It also normally has a delay of 2 hours or more between when the weld was radiographed and when the radiographic film of the weld is available for interpretation. Over the last few years, a newer approach to performing radiographic testing, called ''realtime'' radiography, has been used in several different types of field inspection operations. The realtime radiography system forms the image with optical imaging in lieu of photographic film. Objectives of this project were: (Task 1) Integration of realtime x-ray system ...
We wanted to evaluate the status of self-expandable nitinol stents implanted in the P2 and P3 segments of the popliteal artery in Korean patients. We retrospectively analyzed 189 consecutive patients who underwent endovascular treatment for steno occlusive lesions in the femoropopliteal artery from July 2003 to March 2009, and 18 patients who underwent stent placement in popliteal arterial P2 and P3 segments were finally enrolled. Lesion patency was evaluated by ultrasound or CT angiography, and stent fracture was assessed by plain X-rays at 1, 3, 6 and 12 months and annually thereafter. At the 1-month follow-up, stent fracture (Type 2) was seen in one limb (up to P3, 1 of 18, 6%) and it was identified in seven limbs at the 3-month follow-up (Type 2, Type 3, Type 4) (n = 1: up to P2: n = 6: P3). At the 6-month follow-up, one more fracture (Type 1) (up to P3) was noted. At the 1-year follow-up, there were no additional stent fractures. Just four ...
We succeeded in synthesizing a new cubic intermetallic compound PrCu_4Ag in a fcc structure. Measurements of X-ray diffraction, magnetic susceptibility, magnetization, specific heat, electrical resistivity, thermal expansion, and elastic constants have been performed on single crystals of PrCu_4Ag. A maximum value of #chi#(T) with a corresponding peak in C(T) suggests that an antiferromagnetic phase transition occurs at T_N=2.4 K, where a sudden decrease in #rho#_4_f(T) and a sharp peak in the thermal expansion coefficient #alpha#(T) were observed. Characteristic Curie-type softening was observed in the temperature dependence of the transverse mode for (C_1_1 - C_1_2)/2 and C_4_4 from 70 K down to T_N, which implies that the crystalline electric field (CEF) ground state is the magnetic triplet #GAMMA#_5. The anisotropic properties in M(T,H) and C(T,H) are studied when the external magnetic field is applied in the <100>, <110>, and ...
Aim: To evaluate the role of computed tomography (CT) in needle placement for ganglion impar blocks, and to determine the efficacy of CT-guided ganglion impar blocks in the management of coccydynia. Materials and methods: The results of ganglion impar blockade in eight patients with coccydynia secondary to trauma or unknown cause were reviewed. The diagnosis of coccydynia was based on clinical history, location of pain, and response to previous diagnostic and therapeutic procedures. The eight patients were treated with CT-guided ganglion impar blocks to manage their coccyx pain after conservative procedures, including oral medication and cushions, failed to provide relief. All patients were subjected to ganglion impar blocks under a thin-section CT-guided technique for needle placement, using a mixture of bupivacaine and triamcinolone. The patients were followed-up for a period of 6-months. Results: ...
Surgical resection is the only curative treatment strategy for intrahepatic cholangiocarcinoma (CC). Therefore, accurate staging is essential for appropriate management of patients with CC. We assessed the usefulness of 2-["1"8F]fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) in the staging of CC. We undertook a retrospective review of FDG PET images in 21 patients (10 female, 11 male; mean age 57 years) diagnosed with CC. Ten patients had hilar CC and 11, peripheral CC. Patients underwent abdominal magnetic resonance imaging (MRI) (n=20) and computed tomography (CT) (n=12) for the evaluation of primary tumours, and chest radiography and whole-body bone scintigraphy for work-up of distant metastases. For semi-quantitative analysis, the maximum voxel standardised uptake value (SUV_m_a_x) was obtained from the primary tumour. All peripheral CCs showed intensely increased FDG uptake, and some demonstrated ...
Objective: To investigate the value ofMSCT in observing the direct findings of hilar cholangiocarcinoma1Methods Multislice helical CT studies were performed on the upper abdomen in 19 consecutive patientswith painless jaundice1 Precontrast and dynamic contrast enhanced (25 s phase and 60 s phase) scanswere conducted, and 3D imageswere reconstructed using enhanced raw data in 15 cases1 The direct CT findings of hilar cholangiocarcinoma were studied by three radiologists respectively in a 32scale strategy1 The morphological features and extension of bile duct involvement by hilar cholangiocarcinoma were analyzed1 All the 19 caseswere pathologically p roved as hilar cholangiocarcinoma by surgery (15 cases) and ERCP ( 4 cases) 1 Results The direct findings and extension of hilar cholangiocarcinoma could be demonstrated in 14 out of 15 3D reconstruction images, 8 out of 19 in 25 s phase, and 7 out of 19 in 60 s phase of contrast ...
To evaluate injury patterns of facet joints and associated soft tissue injuries in patients with acute traumatic cervical facet joint injuries. From among patients with cervical spine trauma, 27 with facet joint injuries, as seen on CT and MRI, were chosen for this study. CT scans were analyzed with regard to the location of facet joint injury, the presence or absence of facet dislocation or fracture, and other associated fractures. MR images were analyzed with regard to ligament injury, intervertebral disc injury, intervertebral disc herniation, and spinal cord injury. The most common location of facet joint injury was C6-7 level(n=10), followed by C5-6(n=8). Among these 27 patients with facet joint injuries, 12(44%) had bilateral injuries and 15(56%) unilateral injuries. Facet fractures were present in 17 cases(63%) and the fracture of inferior facet was more frequent than superior. Patterns of fracture were vertical, ...
To study the utility of ultrasound and computed tomography (CT) in case of suspected appendicitis. To determine the diagnostic yield in terms of different clinical contexts and patient characteristics. to assess the costs and benefits of introducing these techniques and propose a protocol for their use. Negative appendectomies, complications and length of hospital stay in a group of 152 patients with suspected appendicitis who underwent ultrasound and CT were compared with those of 180 patients who underwent appendectomy during the same time period, but had not been selected for the first group: these patients costs for each group were calculated. In the first group, the diagnostic value of the clinical signs was also evaluated. The reliability of the clinical signs was limited, while the results with ultrasound and CT were excellent. The incidence of negative appendectomy was 9.6% in the study group and 12.2% in the ...
To evaluate the normal development of the paranasal sinuses in children with CT, authors prospectively studied with brain CT scans of 260 children without known sinus disease, ranging image from 7 days to 16 years. Maximal anteroposterior and transverse diameters(mm) and maximal cross- sectional area(mm{sup 2}) of both sides of the maxillary sinus were measured with the aid of computer device. As to the ethmoidal and spheroidal sinuses, we simply documented the presence of the aplastic ethmoidal sinus and calculated the age-incidence of the spheroidal sinus pneumatization, respectively.There noted three phases in the development of the maxillary sinus. The anteroposterior and transverse diameters of the maxillary sinus increased nearly in parallel. The former was always greater than the latter. In no cases was the edathamil sinus aplastic and almost all sinuses were pneumatized even in infants as early as 7 old days. ...
To assess the CT findings of intrahepatic cholangiocarcinoma associated with hepatolithiasis. The CT features of 26 patients with cholangiocarcinoma and hepatolithiasis were reviewed and compared with those of 23 patients with intrahepatic stones alone, acting as control subjects. CT findings were analyzed for tumor appearance and adjacency to hepatolithiasis. We studied clinical findings, noting the presence or absence of wall thickening or soft tissue attenuation within the bile duct, the luminal diameter of dilated bile duct, and the presence of periductal enhancement, and compared these with the findings for control groups. CTimages of the tumor revealed a hepatic low-attenuating mass with peripheral rim enhancement(n = 14,54 %), or periductal thickening, or low-attenuating lesions in segmental dilatation of intrahepataic bile ducts(n = 12, 46 %). Most hepatic tumors were seen ...
The aim of this study was to compare a 1-day with a 2-day iodine bowel preparation for CT colonography in a positive faecal occult blood test (FOBT) screening population. One hundred consecutive patients underwent CT colonography and colonoscopy with segmental unblinding. The first 50 patients (group 1) ingested 7*50 ml iodinated contrast starting 2 days before CT colonography. The latter 50 patients (group 2) ingested 4*50 ml iodinated contrast starting 1 day before CT colonography. Per colonic segment measurements of residual stool attenuation and homogeneity were performed, and a subjective evaluation of tagging quality (grade 1-5) was done. Independently, two reviewers performed polyp and carcinoma detection. The tagging density was 638 and 618 HU (p = 0.458) and homogeneity 91 and 86 HU for groups 1 and 2, respectively (p = 0.145). The tagging quality was graded 5 (excellent) in 90% of all segments ...
Mycobacterium xenopi is one of the most common agents responsible for nontubercolar mycobacterial pulmonary disease on AIDS patients. These lesions have been studied with conventional radiography while CT has been used in patients with a specific mycobacterioses or non-AIDS pulmonary conditions from Mycobacterium xenopi. 12 AIDS patients were examined. They had pulmonary lesions from Mycobacterium xenopi, patients age ranged 30 to 46 years. All patients had CD4 blood levels lower than 250 cells/mL and Mycobacterium xenopi in the sputum. All patients underwent a standard chest radiograph and a CT examination. CTimages were evaluated by three radiologists independently and the definitive diagnosis was made in the presence of a fourth radiologist. Chest CT showed parenchymal consolidation in 66% of cases, associated with bilateral basal bands in 16% of cases. Consolidation was ...
The purpose of this work is to develop a novel feature-based registration strategy to automatically map the rectal contours from planning computed tomography (CT) (pCT) to cone beam CT (CBCT). The rectal...Full Text Available
A convolution/superposition method is proposed for use with primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. It should be noted that the number of energy bins is usually about ten, and that the reconstructed X-ray spectra can reasonably be applied to media with a wide range of effective Z numbers, ranging from water to lead. The study was carried out for 10-MV X-ray doses in water and thorax-like phantoms with the use of open-jaw-collimated fields. The dose calculations were made separately for primary, scatter, and electron contamination dose components, for which we used two extended radiation sources: one was on the X-ray target and the other on the flattening filter. To calculate the in-air beam intensities at po...
Sonography, subtraction scintigraphy, computed tomography and MRI were compared in 100 patients who had surgery 105 times for hyperparathyroidism (HPT). Surgical and pathological data were available for all operations. A total of 105 MR, 77 CT, 84 sonograms and 70 subtraction scintigrams were performed. The ability of the imaging modalities, individually and in combination, to detect HPT, histology, size, concomitant thyroid disease and location of the diseased glands has been evaluated. For primary HPT, sensitivity ranged from 68% for MRI to 40% for scintigraphy but was much lower for tertiary HPT with all modalities. The ability to identify diseased glands was strongly size dependent for all methods. If patients had had previous neck surgery, the most sensitive methods were MRI and scintigraphy and this also held true for patients with concomitant thyroid disease and ectopically located glands. The findings presented suggest that while ...
Experiments were conducted to confirm the isotropic spatial resolution of multislice CT with a 0.5 mm slice thickness. Isotropic spatial resolution means that the spatial resolution in the transaxial plane (X-Y plane) and that in the longitudinal direction (Z direction) are equivalent. To obtain point spread function (PSF) values in the X-Y-Z directions, three-dimensional voxel data were obtained by helical scanning of a bead phantom. The modulation transfer function (MTF) values were then obtained by three-dimensional Fourier transform of the PSF. Evaluation of the spatial resolution in the X-Y-Z directions by the MTF values showed that the spatial resolution in the Z direction does not depend on the reconstruction kernel used. It was also found that the spatial resolution in the Z direction, as compared with that in the X-Y plane, is superior with the standard kernel for the abdomen and is inferior with the high-definition kernel for the ears/bones. By performing ...
The principle is described of X-ray fluorescence analysis and the manner of detecting the emitted characteristic radiation. The advantages are presented of radionuclide X-ray fluorescence analysis which consist primarily in the possibility of conducting a totally non-destructive analysis, and of accurate and relatively narrow localization of the analyzed area, the simultaneous qualitative and quantitative determinations of a large number of elements in the order of concentrations 10"1 to 10"-"4%, stability of excitation radiation flux, simple design and relatively low capital costs. The so-called matrix effect is pointed to. A number of examples is given of the use of the cited method, including its use in the analysis of art objects. (J.B.).
Some aspects of metrological provision of X-ray radiometric analyzers for mineral raw composition and gamma-gamma-logging equipment are considered. Standard samples (SS) based on the phenol-formaldehyde resin with the introduced quantities calculated of element compositions in the form of oxides and salts are described. Principles of metrological provision developed are used when carrying out state acceptance tests of X-ray radiometric analyzer RAL-M-102 ''Ehkran'' and gamma-gamma-logging equipmnt RSK-102. Economic benefit from introduction of an SS set is #approx# 60-100 thousand roubles per year.
The utilization of nuclear medicine bone scanning examinations early in the diagnostic process allows physicians to render prompt and correct treatment in urgent or difficult athletic cases. Bone scanning should be performed for athletic injuries whenever (1) x-rays are normal but bone or joint pain persists; (2) x-rays are positive but it cannot be determined if the findings are acute or chronic; (3) soft-tissue injuries present and x-rays are not useful; and (4) bone pain or joint impairment present without a history of trauma.89 references.
The textbook is primarily intended for radiologic staff and radiologic safety officers and gives information on the current regulatory provisions of the German X-ray Ordinance, applications of X-rays, quality assurance, organisational aspects of film processing and quality requirements of X-rays. An annex lists the guidelines of the Bundesaerztekammer (German National Chamber of Physicians) relating to quality assurance aspects, and further useful information on commercially available film-screen systems, the various associations of physicians in Germany, and requirements and performance of radiation surveys. (vhe).
Prior to routine use, all newly installed x-ray machines must have a radiation-protection survey by a qualified expert. The survey is an evaluation of existing or potential radiation hazards associated with the use of diagnostic x-ray equipment under specific conditions. Such evaluation includes the measurement of exposure levels in the environment as well as environmental levels arising from operation of the equipment. The survey also includes an evaluation of the safety characteristics of the x-ray unit.
Contributions to the population dose due to medical applications of ionising radiation are presented. It appears that contributions due to radiotherapy and Xray diagnosis are of comparable magnitude. To account for the age dependency of the radiation risks, contributions in terms of somatically significant dose equivalent are calculated as 0.3 mSv per caput per annum for Xray diagnosis and as 0.2 mSv per caput per annum for radiotherapy, the latter referring to only doses to organs outside the target volume. (author).
At the RIKEN-RAL Muon Facility, {mu}{sup -} to {alpha} sticking K{sub {beta}} X-rays were observed for the first time taking advantage of the pulsed beam structure. The precision of the present measurements was insufficient to distinguish between theoretical models, however the observed K{sub {beta}}/K{sub {alpha}} X-ray intensity ratio tends to be smaller than most of these theoretical predictions.
Total M X-ray cross sections for 12 elements in atomic range 70#<=#Z#<=#92 were measured at 5.96 keV Mn K X-ray photon energy. The average M shell fluorescence yields (anti #omega#_M) of these elements have also been observed using the presently measured cross section values and the theoretical M shell photoionisation cross section values. (orig.).
The L-subshell and total M-shell X-ray production cross sections of Ta, W, Pt, Au, Pb and Bi have been measured by protons of energy between 0.7 and 2.4 MeV. The obtained results for X-ray production cross sections have been compared with the existing experimental data, prediction of the ECPSSR theory and also with fitted empirical cross sections of Strivay and Weber.
The results of studies of the time-resolved luminescence of self-trapped excitons (STE) with different multiplicity as well as the X-ray emission in oriented BeO crystals under excitation in the vicinity of the 1 s Be photoabsorption edge are presented. The branching of the electronic excitations relaxation depends strongly on the crystal orientation after the inner-shell excitation. The common features between the processes of the STE luminescence and resonantly excited X-ray fluorescence have been discussed.
A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.
As part of a project to complete a comprehensive catalogue of astrophysically relevant emission lines in support of new-generation X-ray observatories using the Lawrence Livermore electron beam ion traps EBIT-I and EBIT-II, we studied emission lines of argon and sulfur in the soft X-ray and extreme ultraviolet region. Here we present observations of Ar IX through Ar XVI and S VII through S XIV between 20 and 75 {angstrom} to illustrate our work.
The use of X-ray scattering techniques in pharmaceutical science is increasing, in part through increased collaborations with the materials science community, and through increased availability of instrumentation, particularly synchrotron sources. The ability to understand not only the biopharmaceutical outcome, but also arguably, more importantly, the structural aspects of drugs and drug delivery systems, is essential to progressing pharmaceutical science; this review serves as an introduction to the major techniques and the wide range of areas in which X-ray scattering may be applied in understanding and controlling structure in pharmaceutical systems.
Analytic expression is derived for X-ray fluorescence dependence on the particle size of powder and slurry media. The expression is obtained for a model of powder medium containing particles of different size and random distribution in the bulk of the sample. Limiting cases of homogeneous and slurry-like media are considered and expressions for calculation of the fluorescence intensity are derived. The results reasonably match the experiment for binary powder mixtures and thus provide evaluation of the powder particle size on the fluorescence intensity for multicomponent polydisperse powder medium
We have implemented a virtual Young's double slit experiment for hard X-ray photons with micro-fabricated bi-prisms. We observe fringe patterns with a scintillator, and quantify interferograms by detecting X-ray fluorescence from a scanned 30nm Cr metal film. The observed intensities are best modeled with a near-field, Fresnel analysis. The maximum fringe number in the overlap region is proportional to the ratio of real to imaginary parts refractive index of the prism material. The horizontal and vertical transverse coherence lengths at beamline APS 8-ID are measured.
The physical foundations are described of radionuclide X-ray fluorescence analysis (RXFA) and the table shows the values of K- and L-absorption thresholds and the K- and L-line energies of elements. The calculation of the intensity of characteristic radiation during RXFA proceeds from relations derived for conventional X-ray fluorescence analysis. The choice of the radionuclide source is ruled by the nature of the analysed substance and the used detection technique. The diagram shows the areas of radionuclide sources and the energy of the fluorescence radiation of elements. The table shows the spectra of radionuclide sources suitable for the purposes of RXFA measured by semiconductor Si(Li) and Ge(Li) detectors. (ES).
Periosteal Ewing's sarcoma is an uncommon, but well documented origin of this malignant condition with radiography signs, different from intramedullary growing tumours. Imaging modalities like CT or MRI supply proof of macroscopically intact endosteal cortical surface and free medullary cavity in long bones affected by this periosteal type of malignancy. Definite confirmation is valid after a careful microscopic investigation of the resected specimen. The prognosis of this type of Ewing's sarcoma may be favourable than that of the central type. Early diagnosis and therapy are thus essential. A clinical survey of six observations is given. (orig.).
Magnetic resonance imaging (MRI) of the lung is challenging because of substantial drawbacks. However, lung pathologies that are associated with increased attenuation values in CT enhance visualization in MRI: proton density is increased and tissue-air interfaces, resulting in susceptibility artifacts, are reduced in pneumonia, pneumonitis, edema, and carcinoma. On the other hand, many lung diseases result in shortness of breath, so that patients cannot hold their breath for long periods. Therefore, fast imaging techniques are required which should also allow for high spatial resolution so that small lesions can be detected. Calcifications and air pockets within lesions are not readily recognized with MRI. Thin section CT is standard for the diagnosis of pneumonia. With parallel imaging techniques, MRI examination of the lungs can be performed with short periods of breath holding, ...
Periureteral or subtrigonal injection of dextranomer/hyaluronic acid (Dx/HA) copolymer (Deflux, Q-Med, Uppsala, Sweden) is an increasingly common endoscopic treatment for vesicoureteral reflux. We report a confusing radiographic finding of bilateral calcified Dx/HA injections initially thought to represent bilateral distal ureteral stones in a boy who presented with intermittent periumbilical pain. Urologists, radiologists, and emergency room physicians should be aware of the potential for calcification of ureteral implants of Dx/HA, and of the potentially confusing radiographic images that may result. (orig.)
Conformal radiation therapy represents a considerable and attractive challenge in oncology. Its aim is mainly to improve local control by increasing the dose with an acceptable rate of complications. This work overviews the world literature on this subject. The technical and theoretical requirements are highlighted. These requirements include a precise definition of the target volume by digital imaging (essentially CT scan), but also clear view of the target volume and the organs at risk, a specific collimation of the beam, 3-D dose calculations, optimization procedures, and a rigid immobilization of the patient with verification of his position. Moreover, the clinical applications of conformal radiation therapy are reviewed and discussed. (authors). 80 refs., 1 tab.
A significant amount of X-rays were detected as a leakage from some of the Crooke`s tubes which were used in the teaching of science at junior and senior high schools in Japan. We measured the leaked dose of X-rays from the Crooke`s tubes with ionizing chambers, film badges and TLDs. The maximum leaked dose at 5cm distance from those tubes was estimated 143mSv/h. The effective energy of leaked X-rays was 19.3keV. The maximum dose of students exposed during the teaching of science were estimated 0.15mSv per experiment, which exceeded the value recommended in the ICRP publication 36. (author)
We review the current status of resolved X-ray emission associated with extragalactic radio jets and hotspots. The primary question for any particular jet is to decide if the X-rays come from the synchrotron process or from inverse Compton scattering. There is considerable evidence supporting synchrotron emission for knots in the jets of FRI galaxies. For FRII terminal hotspots detected in the X-ray band, synchrotron self-Compton emission continues to provide viable models with one possible exception (so far). Inverse Compton scattering on photons of the cosmic microwave background is indicated for a few powerful jets, and is expected to be an important contributor if not the dominating mechanism for higher redshift objects. The application of a model generally yields physical parameters and in many cases, these include the Doppler boosting factor.
... Special Purpse Lead Azide Lot #I3A-4-62 ... Standard X-ray techniques are not sufficiently sensitive ... the National Bureau of Standards, and examined ...
Resonant inelastic x-ray scattering (RIXS) with soft x-rays is uniquely suited to study the elec-tronic structure of a variety of materials, but is currently limited by low (fluorescence yield) count rates. This limitation is overcome with a new high-transmission spectrometer that allows to measure soft x-ray RIXS"maps." The S L2,3 RIXS map of CdS is discussed and compared with density functional calculations. The map allows the extraction of decay channel-specific"absorp-tion spectra," giving detailed insight into the wave functions of occupied and unoccupied elec-tronic states.
Objective: To investigate the X-ray radiation dose patients dealt with the hepatic intervention. Methods: Thermoluminescence and tissue-equivalent anthropomorphic phantom were used to measure the X-ray radiation dose in patients dealt with the hepatic intervention in 85 patients. Results: The peak skin dose in the patients who accepted hepatic intervention was from 179.95 to 1759.00 mGy, effective dose approached 29.22 mSv (male), 29.27 mSv (female). Conclusion: Hepatic intervention is now regarded as an important therapeutic method for liver cancer. However, the patients were exposed to too much X-ray radiation during interventional procedures. Some more effective protection should be taken to decrease the X-ray radiation dose accepted by patients. (authors)
The time and dose characteristics of the electron and X-ray radiations of a tube, connected to a subnanosecond mega volt accelerator, are measured. By the pulse of the accelerating voltage of #>=# 600 kV with duration of #approx =# 0.3 ns the tube generates approximately 5 x 10"1"2 electrons pulse. The current amplitude equals approximately 5 kA/pulse and the radiation dose-about 5 kGy/pulse. The X-ray radiation dose from the tantalum external target constitutes 0.15 Gy/pulse. The prototypes of the electron and X-ray tubes sufficiently lower volumes, opening new applications in the technique and medicine, are developed
The L-shell x-ray intensity ratios I(L_#beta#)/I(L_#alpha#) and I(L_#gamma#)/I(L_a_l_p_h_a) for elements with 73 #<=# Z #<=# 83 have been measured at photon incident energies of 17.8, 25.8 and 46.9 keV. The emitted x-rays were measured with a Si(Li) detector system. The results for Re, Pt and Tl are being reported for the first time. A comparison is made of the experimental results with the calculated values obtained by using the theoretical x-ray emission rates, subshell ionisation cross sections, subshell fluorescence yields and Coster-Kronig transition probabilities. The experimental results are in reasonable agreement with the theoretical values. (author).
by the radionuclide X-ray fluorescence analysis into several groups according to the atomic number of the determined element. Table I documents this. ...
M-shell X-ray production cross sections for the light rare-earth elements of {sup 68}Er, {sup 7}Yb and {sup 71}Lu have been measured for incident {sup 4}He{sup +} ions in the energy range from 0.75 to 6 MeV. The measured X-ray production cross sections are compared to the predictions of the First Born approximation, the ECPSSR theory and the ECUSAR theory. A comparison of the ytterbium M-shell X-ray production cross sections with these theories is made for two different sets of fluorescence yields and Coster-Kronig factors that are further modified for multiple ionization.
The available data on isolated X-ray pulsars, their wind nebulae, and the supernova remnants which are connected to some of these sources are analyzed. It is shown that electric fields of neutron stars tear off charged particles from the surface of neutron star and trigger the acceleration of particles. The charged particles are accelerated mainly in the field of magneto-dipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magneto-dipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.
The development of new efficient afterglow phosphors is currently hampered by a limited understanding of the persistent luminescence mechanism. Radioluminescence (RL) and x-ray absorption measurements on the persistent phosphor SrAl2O4:Eu,Dy were combined to reveal possible valence state changes for the rare earth (co)dopants. Traps in the phosphor material are quickly filled when exposing thermally emptied SrAl2O4:Eu,Dy powder to xrays. On the same time scale a partial oxidation of Eu2+ to Eu3+ is observed by x-ray absorption near-edge spectroscopy (XANES), while for the trivalent dysprosium the valence state remains unchanged. The impact of these observations on the recently proposed models for persistent luminescence is discussed.
Jul 25, 2011 ... Koji Mukai's Bibliography. Invited Reviews. Mukai, K. 1994, "ASCA PV Phase Observations of Cataclysmic Variables," in "New Horizon of X-ray ...
The X-ray intensity ratio K_#beta#/K_#alpha# has been measured by using a 10 mCi "5"5Fe source (Mn K X-rays) and high resolution Si(Li) detector system coupled to a computer-controlled multichannel analyzer over the range of 15#<=#Z#<=#22. Correction have been made to the measured relative intensities (K_#alpha# and K_#beta# X-rays) for self-absorption in the sample, air, Be-window absorption and detection efficiency. The results are compared with those of other experiments and with the Scofield calculations. (author) 13 refs.; 3 figs.; 2 tabs.
We briefly review capabilities and requirements for future instrumentation in UV- and X-ray astronomy that can contribute to advancing our understanding of the diffuse, highly ionised intergalactic medium.
We present preliminary analysis for the feasibility of the attosecond x-ray pulses at a proposed FERMI@ELETTRA free electron laser (FEL) [1]. In part 1 we restrict ourselves to minimal modifications to the proposed FEL and consider a scheme for attosecond x-ray production which can be qualified as a small add-on to a primary facility. We demonstrate that at 5-nm wavelength our scheme is capable for production of pulses with an approximate duration of 100 attoseconds at approximately 2 MW peak power and with an absolute temporal synchronization to a pump laser pulse. In part 2 we propose to use an FEL amplifier seeded by a VUV signal and to follow it by the scheme for attosecond x-ray production described in part 1.
The Warm-Hot Intergalactic Medium (WHIM) arises from shock-heated gas collapsing in large-scale filaments and probably harbours a substantial fraction of the baryons in the local Universe. Absorption-line measurements in the ultraviolet (UV) and in the X-ray band currently represent the best method to study the WHIM at low redshifts. We here describe the physical properties of the WHIM and the concepts behind WHIM absorption line measurements of H I and high ions such as O VI, O VII, and O VIII in the far-ultraviolet and X-ray band. We review results of recent WHIM absorption line studies carried out with UV and X-ray satellites such as FUSE, HST, Chandra, and XMM-Newton and discuss their implications for our knowledge of the WHIM.
Jan 22, 2011 ... dc.description.abstract, The progress in the development of a surface analysis tool based on the excitation of characteristic luminescence ...
The available data of single X-ray pulsars, their wind nebulae, and the SNRs which are connected to some of these sources are analysed. It is shown that electric field intensity of neutron stars tears off charged particles from the surface of neutron star and triggers the acceleration of particles. The charged particles are accelerated mainly in the field of magnetodipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magnetodipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.