WorldWideScience
1

PIXE analysis of GaAs and ZnSe  

Energy Technology Data Exchange (ETDEWEB)

The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K{sub {alpha}} X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K{sub {alpha}} X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. ...

1990-01-01

2

PIXE analysis of GaAs and ZnSe  

International Nuclear Information System (INIS)

The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K_#alpha# X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K_#alpha# X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The ...

1989-06-01

3

Optimization of X-ray energy resolution from a horizontally focused single-crystal monochromator  

Energy Technology Data Exchange (ETDEWEB)

A method has been developed to optimize the energy resolution of a horizontally focusing monochromator. The method consists of determining the optimum radius of curvature of the cylindrically bent monochromator crystal by minimizing the total diffracted X-ray flux measured through an X-ray absorption foil. When measured at an absorption edge a global minimum can be identified, which corresponds to the minimum energy band accepted along the entire length of the crystal. Experimental verification of this method has been validated by comparing X-ray fluorescent scans taken for a series of crystal curvatures and by directly measuring the X-ray beam profiles at the corresponding points. The actual optical configuration and asymmetric-cut parameter of the focusing monochromator on beamline X4C at the National Synchrotron Light Source are modeled ...

2009-02-11

4

Energy Dispersive X-ray Analysis in the Electron Microscope  

CERN Document Server

Energy Dispersive X-ray Analysis in the Electron Microscope

2003-01-01

5

Measurements of K-beta/K-alpha X-ray intensity ratios using VEC beams  

International Nuclear Information System (INIS)

An experiment on the K#beta#/K#alpha# characteristic X-ray intensity ratio in silver was performed at VEC Centre, Calcutta using the #alpha#-beams at energies 40 MeV and 50 MeV employing a Si(Li) detector system on-line. The results show that the K#beta#/K#alpha# X-ray intensity ratio at energies 40 and 50 MeV are 0.215 #+-# 0.006 and 0.216 #+-# 0.006, respectively, which indicates no change with beam energy and in accordance with the earlier reports. The present experiment shows the feasibility of studying the K#beta#/K#alpha# ratios as a function of beam energy in different regions of periodic table. Experiments in elements belonging to the 3d shell and their compounds are suggested to look for the chemical effects and their dependence on #alpha#-energy. (author). 7 refs.

1987-02-03

6

The ANL X6B beamline at NSLS: A versatile facility  

Energy Technology Data Exchange (ETDEWEB)

We have described the x-ray optics and beamline performance of the ANL X6B beam line at the NSLS. Considerable flexibility has been built into the beam line to accommodate a wide range of x-ray diffraction, scattering, and spectroscopy experiments with various requirements. We presented selected examples of experimental results and showed that with the high intensity, high energy resolution, high-q resolution, and energy tunability, the X6B beam line has become a versatile facility.

1994-07-01

7

Beam-induced damage on diffractive hard X-ray optics  

UK PubMed Central (United Kingdom)

The issue of beam-induced damage on diffractive hard X-ray optics is addressed. For this purpose a systematic study on the radiation damage induced by a high-power X-ray beam is carried out in both...Full Text Available

2010-11-01

8

A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: a theoretical study on 10-MV X-ray dose calculations in thorax-like phantoms  

British Library Electronic Table of Contents (United Kingdom)

A convolution/superposition method is proposed for use with primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. It should be noted that the number of energy bins is usually about ten, and that the reconstructed X-ray spectra can reasonably be applied to media with a wide range of effective Z numbers, ranging from water to lead. The study was carried out for 10-MV X-ray doses in water and thorax-like phantoms with the use of open-jaw-collimated fields. The dose calculations were made separately for primary, scatter, and electron contamination dose components, for which we used two extended radiation sources: one was on the X-ray target and the other on the flattening filter. To calculate the in-air beam intensities at po...

2011-01-01

9

Stabilization of synchrotron radiation x-ray beam by MOSTAB  

International Nuclear Information System (INIS)

Monochromator stabilization (MOSTAB) is a feedback control system to stabilize an x-ray beam of synchrotron radiation. It applies a feedback voltage to a piezo electric transducer attached to a double-crystal monochromator. We developed MOSTAB modules and examined their performances using SPring-8 beamlines. The x-ray beam position stabilization using MOSTAB was realized simultaneously with the x-ray beam intensity stabilization. As an example of its application, we performed EXAFS measurement with MOSTAB. (author)

2003-05-01

11

The infrared-dominated jet of 3C401  

CERN Document Server

We present a Hubble Space Telescope image of the FRII radio galaxy 3C 401, obtained at 1.6 microns with the NICMOS camera in which we identify the infrared counterpart of the brightest region of the radio jet. The jet has a complex radio structure and brightens where bending occurs, most likely as a result of relativistic beaming. We analyze archival data in the radio, optical and X-ray bands and we derive its spectral energy distribution. Differently from all of the previously known optical extragalactic jets, the jet in 3C401 is not detected in the X-rays even in a long 48ksec X-ray Chandra exposure and the infrared emission dominates the overall SED. We propose that the dominant radiation mechanism of this jet is synchrotron. The low X-ray emission is then caused by two different effects: i) the lack of any strong external photon field and ii) the shape of ...

2005-01-01

12

Spherically bent crystal spectroscopy in laser-produced plasma  

International Nuclear Information System (INIS)

A curved crystal X-ray spectrographs of reflection type spherical geometry was required based on the Johann scheme. Due to their high efficiency and resolution, X-ray spectrographs of focusing spectrograph spatial resolution are suitable for detecting weak X-ray spectra in spectrometers for laser fusion research. Spherically bent mica crystal with a radius of curvature of 380 mm was used in the spectrometer. The Bragg angle of the crystal analyzer was 51 degree. The image plate was employed to obtain high spatial resolution and a narrow spectral band width, with an effective area of 30 mm x 80 mm. The designed optical path of the X-ray spectrometer beam was 980 mm long from the source to the crystal and the detector. The first experiment was carried out at the 20 J energy laser facility of Research Center of Laser Fusion, China Academy of Engineering Physics. ...

2008-02-01

13

Subacute neuropathological effects of microplanar beams of x-rays from a synchrotron wiggler.  

UK PubMed Central (United Kingdom)

Microplanar beam radiation therapy has been proposed to treat brain tumors by using a series of rapid exposures to an array of parallel x-ray beams, each beam having uniform microscopic thickness and...Full Text Available

1995-09-12

14

Key comparison BIPM.RI(I)-K2 of the air-kerma standards of the ARPANSA and the BIPM in low-energy X-rays  

International Nuclear Information System (INIS)

A key comparison has been made between the air-kerma standards of the ARPANSA and the BIPM in the low-energy X-ray range. The results show the standards to be in agreement at the level of the combined standard uncertainty of 7.0 parts in 10"3 for the 10 kV radiation quality and 3.7 parts in 10"3 for all other beam qualities. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. (authors)

2010-12-01

15

Dose, exposure time, and resolution in Serial X-ray Crystallography  

CERN Document Server

The resolution of X-ray diffraction microscopy is limited by the maximum dose that can be delivered prior to sample damage. In the proposed Serial Crystallography method, the damage problem is addressed by distributing the total dose over many identical hydrated macromolecules running continuously in a single-file train across a continuous X-ray beam, and resolution is then limited only by the available molecular and X-ray fluxes and molecular alignment. Orientation of the diffracting molecules is achieved by laser alignment. We evaluate the incident X-ray fluence (energy/area) required to obtain a given resolution from (1) an analytical model, giving the count rate at the maximum scattering angle for a model protein, (2) explicit simulation of diffraction patterns for a GroEL-GroES protein complex, and (3) the frequency cut off of the transfer function ...

2007-01-01

16

A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: comparison of calculated and measured 10-MV X-ray doses in thorax-like phantoms  

British Library Electronic Table of Contents (United Kingdom)

We performed experimental studies on the convolution/superposition method reported in the former companion paper (Iwasaki in Radiol Phys Technol 4, 2011) using 10-MV X-ray beams from open-jaw-collimated fields. The method uses primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. We made a comparison of calculations and measurements in water phantoms and thorax-like phantoms with respect to percentage depth dose curves, tissue???phantom ratio curves, and dose profiles. We made the dose calculation by taking into account the beam-hardening effect with depth and the off-axis radiation-softening effect. We found that the method could be used, in general, for performing accurate dose calculations.

2011-01-01

17

M X-ray production in Nd, Gd, Ho and Lu by 1-6 MeV lithium ions  

Energy Technology Data Exchange (ETDEWEB)

M-shell X-rays of the rare-earth elements {sub 60}Nd, {sub 64}Gd, {sub 67}Ho and {sub 71}Lu were measured for lithium ion bombardment in the energy range 1.0-6.0 MeV. The M-shell X-rays with energies of 0.978-1.631 keV were detected with a LINK analytical detector. The efficiency of the detector was determined by using the known atomic-field bremsstrahlung cross-sections from low energy electron beams and K-shell X-ray measurements with light projectiles. The measured cross-sections are compared to the predictions of the first Born approximation and the ECPSSR (energy loss and Coulomb deflection effects, perturbed stationary state approximation with relativistic correction) theories. The best theoretical description of the present data is given by the ECPSSR theory, even though the discrepancy between data and theory is ...

2004-06-01

18

Analysis of Longitudinal Space Charge Effects With Radial Dependence  

Energy Technology Data Exchange (ETDEWEB)

Longitudinal space charge (LSC) force can be a main effect driving the microbunching instability in the linac for an x-ray free-electron laser (FEL). In this paper, the LSC-induced beam modulation is studied using an integral equation approach that takes into account the transverse (radial) variation of LSC field for both the coasting beam limit and bunched beam. Changes of beam energy and the transverse beam size can be also incorporated. We discuss the validity of this approach and compare it with other analyses as well as numerical simulations.

2005-09-30

19

Design considerations for the magnetic system of a prototype x-ray free electron laser  

Energy Technology Data Exchange (ETDEWEB)

A number of difficult technical challenges need to be solved in the fields of accelerator and free-electron laser (FEL) technologies in order to build an X-ray FEL. One of the tasks well suited to the Advanced Photon Source Low Energy Undulator Test Line (LEUTL) is to take the intermediate step of solving some of the problems of single-pass FEL operation in the ultraviolet range. The existing Advanced Photon Source (APS) linac, in addition to its role of supply positrons for the APS storage ring, will also be used to generate the particle beam for the LEUTL. Here, the design of the magnetic system for the high gain soft x-ray free electron laser is described.

1997-04-01

20

Evolution of surface roughness in silicon X-ray mirrors exposed to a low-energy ion beam  

International Nuclear Information System (INIS)

The possibility of smoothening aspherical X-ray mirrors by irradiation of the surface with a low-energy ion beam is investigated. Nanofocusing being the primary application of these mirrors the ion beam conditions must be optimized to achieve a surface roughness of the order of 0.1-0.2 nm. To address this issue a first study was performed on silicon flat substrates etched using ion energies ranging from 400 to 1200 eV. A second study consisted of eroding the silicon surface while varying the ion grazing incidence angle between 10 deg. and 90 deg. for a fixed value of the ion energy. The surface topography of the samples was characterized at various scales using atomic force microscopy (probed area: 1-10 ?m2), interferential optical microscopy (probed area: 1 mm2) and X-ray scattering (probed area: 100 mm2). Finally, a study by AFM of the ...

2010-05-01

21

APMP/TCRI key comparison report of measurement of air kerma for medium-energy x-rays (APMP.RI(I)-K3)  

Energy Technology Data Exchange (ETDEWEB)

The APMP/TCRI Dosimetry Working Group performed the APMP.RI(I)-K3 key comparison of measurement of air kerma for medium-energy x-rays (100 kV to 250 kV) between 2000 and 2003. In total, 11 institutes took part in the comparison, among which 8 were APMP member laboratories. Two commercial cavity ionization chambers were used as transfer instruments and circulated among the participants. All the participants established the 100 kV, 135 kV, 180 kV and 250 kV x-ray beam qualities equivalent to those of the BIPM. The results showed that the maximum difference between the participants and the BIPM in the medium-energy x-ray range, evaluated using the comparison data of the linking laboratories ARPANSA and PTB, is less than 1.4%. The degrees of equivalence between the participants are presented and this comparison confirms the calibration capabilities of the ...

2008-10-15

22

Metrological applications of X-ray waveguide thin film structures in X-ray reflectometry and diffraction  

International Nuclear Information System (INIS)

The effect of resonance, observed in X-ray waveguide layered structures in a characteristic way influences the scattering properties of the films. It is well known that the resonant region in the reflectivity shows a series of minima, usually very deep and extremely narrow. The positions and depths of the minima depend only on X-ray waveguide and quasi X-ray waveguide film structural properties, on the X-ray wavelength and on the incident beam divergence. In the present work we propose and discuss the application of the X-ray waveguide and quasi X-ray waveguide film structures as a tools to experimental evaluation of some quantities related to X-ray reflectometric and diffractometric measurements, like the beam divergence, wavelength, or angular distance. Examples of application of ...

2001-09-23

23

Improved beam confinement in the modified betatron with strong focusing  

International Nuclear Information System (INIS)

The lifetime of the circulating electron beam in the Naval Research Laboratory modified betatron has been increased by more than 2 orders of magnitude with the addition of strong focusing windings to the device. The injected beam consistently spirals from the injector to the minor axis and is trapped. The #approx#0.5-kA trapped electron ring has been accelerated above 10 MeV from the injection energy of 0.5 to 0.6 MeV. The beam acceleration has been confirmed not only by the x-ray attenuation technique but also with the detection of photoneutrons.

24

X-ray dose enhancement effects  

International Nuclear Information System (INIS)

A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.

25

Automated three-dimensional X-ray analysis using a dual-beam FIB  

International Nuclear Information System (INIS)

We present a fully automated method for three-dimensional (3D) elemental analysis demonstrated using a ceramic sample of chemistry (Ca)MgTiO_x. The specimen is serially sectioned by a focused ion beam (FIB) microscope, and energy-dispersive X-ray spectrometry (EDXS) is used for elemental analysis of each cross-section created. A 3D elemental model is reconstructed from the stack of two-dimensional (2D) data. This work concentrates on issues arising from process automation, the large sample volume of approximately 17x17x10 #mu#m"3, and the insulating nature of the specimen. A new routine for post-acquisition data correction of different drift effects is demonstrated. Furthermore, it is shown that EDXS data may be erroneous for specimens containing voids, and that back-scattered electron images have to be used to correct for these errors.

2007-08-01

26

The energy dependence of L_#alpha#/L_l X-ray intensity ratio produced by heavy-ion bombardment  

International Nuclear Information System (INIS)

The energy dependence of the Yb and Au L_#alpha#/L_l X-ray intensity ratio, produced by 0.5 - 3.0 MeV/u Li, Be, C, N, F, and Si ion bombardment (Malhi and Gray, Phys. Rev. A 44, 7199, (1991)), measured at 90"0 relative to the beam axis, has been explained. While for light ion impact the behaviour of the alignment parameter as a function of impact velocity is dominant, for the impact of heavier ions the multiple ionization effects become important. Using Larkins' prescription in the last case, calculations have been performed, which agree well with the data over the whole energy range investigated. (Author).

1993-01-01

27

28: Calculation of 3D dose distribution for photons in inhomogeneous media  

International Nuclear Information System (INIS)

A method for calculation of absorbed dose distributions in three dimensions for 1-20 MeV photons is presented. The method uses convolution/superposition of photon fluence distributions with energy scattering kernels. Results for Co-60 and X-ray beams in homogeneous and inhomogeneous media are compared with measurements. Good agreement is found between calculations and measurements. 8 refs.; 3 figs.

28

Portal localization images using computed radiography for high-energy electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy electron beam therapy. (author)

2002-09-01

29

Total skin electron beam therapy in mycosis fungoides. Evaluation of a technique for deceleration of electron beam energy and clinical study  

Energy Technology Data Exchange (ETDEWEB)

The studies using phantoms confirmed that the reduction of electron beam energy and minimization of X-ray contamination could be achieved when electron beam was interposed by an acrylic plate placed 20 cm anterior to a patient. Four patients of mycosis fungoides were treated with 8 MeV electron beam of a linear accelerator at UOEH Hospital from October 1981 to December 1986. Two of them were treated with this technique by placing 2 cm thick acrylic plate anterior to the patients and satisfactory results were obtained. Cutaneous lesions subsided remarkably with the dosage of 2000 cGy given in 2 months. Leucopenia due to bone marrow suppression was mild and the patients tolerated the treatment well.

1988-08-01

30

Dosimetric properties of an applicator system for intraoperative electron-beam therapy utilizing a Clinac--18 accelerator  

International Nuclear Information System (INIS)

A prototype electron applicator system providing circular and rectangular fields for use in intraoperative electron beam therapy with a Varian Clinac 18 linear accelerator has been fabricated. The dosimetric properties of this system for a variety of electron-beam energies, applicator sizes, and x-ray collimator settings was documented. Significant findings include: (a) surface dose values are in excess of 90% for electron energies of 12 MeV and above; (b) for the 18-MeV beam, the deepest depth where the central axis dose is 90% of its maximum value is in excess of 50 mm for circular applicators whose diameters are in excess of 5 cm; and (c) the treatment time to deliver 1000 rads ''given dose'' (at a given dose rate of 300 MU/min) is on the order of 3--4 min. Cross-field behavior is acceptable for the intended application and x-ray ...

31

Dosimetry measurements of x-ray and neutron radiation levels near the shuttle and end beam dump at the advanced test accelerator: Beam Research Program  

International Nuclear Information System (INIS)

Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and ...

32

Multi-mirror system, 2. Application of inverse Compton Scattering for lithography X-ray sources  

Energy Technology Data Exchange (ETDEWEB)

A brilliant X ray source is proposed for lithography instruments with use of a multi-mirror system. The inverse Compton scattering between the stored electron beam in the storage ring and the stored photon beam in the multi-mirror system, is applied for the X-ray generation. (author)

2000-07-01

33

Compressed-shell integrity measurements in spherical implosion experiments  

International Nuclear Information System (INIS)

The shell integrity near peak compression of spherical implosions using the 60-beam, 30-kJ UV OMEGA laser system [Opt. Commun. 133, 495 (1997)] has been measured. Hot core emission backlights a shell with a thin titanium-doped layer that is imaged at x-ray photon energies above and below the titanium K edge. The x-ray intensity ratio between the two images is related to perturbations in the cold, or absorbing, part of the shell. The measured cold-shell areal-density modulations, integrated over the time of peak compression, are of the order of 25% to 50% with nonuniformity spectra peaked at spatial wavelengths of 30 to 50 #mu#m and with the smallest detectable nonuniformity features extending down to spatial wavelengths of 12 to 15 #mu#m. Hot-shell areal-density modulations of the emitting part of the shell (inner edge) are of the order of 13% to 20%. The measured shell modulations are in agreement with ...

2001-06-01

34

Visibility of tumor-like details in inline phase contrast mammography using quasimonochromatic X-ray sources  

Energy Technology Data Exchange (ETDEWEB)

A new generation of quasimonochromatic high-flux X-ray sources, based on the X-ray radiation produced through Compton scattering between an electron beam and a laser beam, is under development. One of the possible applications of this source is inline phase contrast mammography, based on the observation of the edge-enhancement effect that can be observed at the border of structures inside the breast in images produced using a partially or totally coherent X-ray beam. In this work we present the results of a set of simulations of inline phase contrast mammography using typical inverse Compton scattering sources parameters. The simulated sample was a tumour-like mass having spherical shape, diameter between 200 {mu}m and 5 mm, placed inside a breast-like matrix, 4 cm thick, and a standard composition of 50% glandular tissue and 50% adipose tissue. We discuss the ...

2009-09-01

35

Beam Test of a Prototype Detector Array for the PoGO Astronomical Hard X-Ray/Soft Gamma-Ray Polarimeter  

CERN Document Server

Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \\pm 0.01$. This was successfully reproduced at the 10% level by the computer simulation package Geant4 after ...

2005-01-01

36

Analysis on Dose Distribution in Heterogeneous Condition for Narrow 6 MV X-ray Beams  

International Nuclear Information System (INIS)

Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous condition since the GAFCHROMICat..EBT ...

2010-10-01

37

Determination of ash content in coal by means of backscattered X-ray radiation and X-ray fluorescence analysis, and devices manufactured by the PAR company  

Energy Technology Data Exchange (ETDEWEB)

Discusses methods for determining ash content in coal using backscattering in X-ray fluorescence. The following aspects are evaluated: principle of ash content determination, energy sources, factors that influence measurement accuracy, reliability. Types of X-ray fluorescence analyzers developed in Czechoslovakia and manufactured in the Czech Republic are comparatively evaluated. Operation of the RPM 113.1 radionuclide X-ray fluorescence analyzer developed by the PAR company and used for measuring ash content in coal and coal calorific value is discussed. 7 refs.

1993-09-01

38

Performance testing of selected types of electronic personal dosimeters used in Sudan  

International Nuclear Information System (INIS)

Measurements were carried out for calibration and performance testing of a set of 10 electronic personal dosimeters (EPDs) at the Secondary Standard Dosimetry Laboratory of Sudan. Calibrations were carried out at three X-ray beam qualities described in ISO standard 4037 in addition to 137Cs and 60Co gamma ray beams. The experimental was performed with EPDs mounted on ICRU Slab phantom. X-ray and ?-ray beams were characterized in terms of air kerma free-in-air which were converted to the known delivered personal dose equivalent, Hp(10) using appropriate the air kerma to personal dose equivalent conversion coefficients. Dosimeters tested showed excellent energy and angular response and relative error of indication within the recommended limit for photon energies from 65 keV to 1.25 MeV. The study showed encouraging results for using electronic ...

2010-12-01

39

Measurement of the K?/K? ratio for muon alpha sticking X-rays in muon catalyzed d-t fusion at the RIKEN-RAL Muon Facility  

International Nuclear Information System (INIS)

At the RIKEN-RAL Muon Facility, ?- to ? sticking K? X-rays were observed for the first time taking advantage of the pulsed beam structure. The precision of the present measurements was insufficient to distinguish between theoretical models, however the observed K?/K? X-ray intensity ratio tends to be smaller than most of these theoretical predictions.

1999-06-01

40

Total skin electron beam therapy in mycosis fungoides  

International Nuclear Information System (INIS)

The studies using phantoms confirmed that the reduction of electron beam energy and minimization of X-ray contamination could be achieved when electron beam was interposed by an acrylic plate placed 20 cm anterior to a patient. Four patients of mycosis fungoides were treated with 8 MeV electron beam of a linear accelerator at UOEH Hospital from October 1981 to December 1986. Two of them were treated with this technique by placing 2 cm thick acrylic plate anterior to the patients and satisfactory results were obtained. Cutaneous lesions subsided remarkably with the dosage of 2000 cGy given in 2 months. Leucopenia due to bone marrow suppression was mild and the patients tolerated the treatment well. (author).

41

The Linac Cooherent Light Source (LCLS) Accelerator  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) is a SASE x-ray Free-Electron Laser (FEL) based on the final kilometer of the Stanford Linear Accelerator. Such an FEL requires a high energy, high brightness electron beam to drive the FEL instability to saturation. When fed by an RF-photocathode gun, and modified to include two bunch compressor chicanes, the SLAC linac will provide such a high quality beam at 14 GeV and 1-{micro}m normalized emittance. In this paper, we report on recent linac studies, including beam stability and tolerances, longitudinal and transverse feedback systems, conventional and time-resolved diagnostics, and beam collimation systems. Construction and installation of the injector through first bunch compressor will be completed by December 2006, and electron commissioning is scheduled to begin in January of 2007.

2007-03-21

42

The Formation of the Low-sized High Density Plasma Structures in the Self-maintained Plasma-beam Discharge  

International Nuclear Information System (INIS)

The opportunity of use self-maintained plasma-beam discharge in an extended pulsing plasma diode of low pressure for making powerful sources of the soft X-rays is investigated. Conditions of formation of the self-maintained plasma-beam discharge are determined. The mode of making of dense high-temperature plasma on the basis of stannum ions in the discharge is shown. The stannum ions are used as a working element of a radiation sources at pulsing power of electron beam P?10...100 MW. Results of the examination on formation of the dense (np?1016 cm3), small sizes (le?100 eV in conditions of working material evaporation from the anode are given. The total contribution of energy to the discharge has made W < 20 J.

2006-01-01

43

Microprobe RBS analysis of localized processed areas by FIB etching and deposition  

International Nuclear Information System (INIS)

Localized beam-processed areas using chemical reactions induced by a 30 keV Ga"+ focused ion beam (FIB) with and without I_2 (etching) and (CH_3)_3CH_3C_5H_5Pt gases (Pt deposition) have been analyzed using a 300 keV Be"2"+ microprobe with a beam spot size of 50-80 nm. The analyzed results have been compared with energy dispersive X-ray (EDX) analysis using an electron beam. The EDX analysis only indicated incorporated impurities at high fluence such as Ga, Pt and C, while microprobe RBS analysis could detect residual iodine with low concentration which couldn't be detected by EDS analysis because of the lower sensitivity of the EDX analysis for heavy atoms.

2001-07-01

44

Ionization-chamber-dependent factors for calibration of megavoltage X-ray and electron beam therapy machines  

International Nuclear Information System (INIS)

When exposure-calibrated ionization chambers are used to calibrate megavoltage X-ray and electron beam therapy machines, the calibration factor can be divided into a chamber-dependent and a chamber-independent component. Until recently, only the chamber-independent part, which has been derived theoretically, has been used; the chamber-dependent component has been ignored. Recent experimental and theoretical considerations, however, have indicated that the dependent component must be taken into account and can affect the calibration by as much as 4%. The calibration can change due to (i) the thickness of the chamber wall, (ii) the chamber wall composition, i.e. whether the chamber is constructed of air-equivalent material, or tissue- or water-equivalent material, and (iii) the size of the chamber changing the displacement factor. Theoretical and experimental evidence indicates that the third factor varies from approximately 4.5% for "6"0Co ...

46

Soft x-ray microradiography and lithograph using a laser produced plasma source. Final report  

Energy Technology Data Exchange (ETDEWEB)

Considering the hardware characteristics of the laser-induced plasma X-ray source and the limitations of the conventional cone-beam reconstruction algorithm, a general cone-beam reconstruction algorithm has been developed at our laboratory, in which the motion locus of the X-ray source is an arbitrary curve corresponding to at least a 2{pi} continuous horizontal angular displacement in the coordinate system of the specimen. The preliminary simulation shows that the general cone-beam reconstruction algorithm consistently results in visually satisfactory images.

1992-03-01

47

Soft x-ray microradiography and lithograph using a laser produced plasma source  

Energy Technology Data Exchange (ETDEWEB)

Considering the hardware characteristics of the laser-induced plasma X-ray source and the limitations of the conventional cone-beam reconstruction algorithm, a general cone-beam reconstruction algorithm has been developed at our laboratory, in which the motion locus of the X-ray source is an arbitrary curve corresponding to at least a 2{pi} continuous horizontal angular displacement in the coordinate system of the specimen. The preliminary simulation shows that the general cone-beam reconstruction algorithm consistently results in visually satisfactory images.

1992-01-01

48

Deposition of Cu film on SiO_2 using a partially ionized beam  

International Nuclear Information System (INIS)

Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO_2 substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio I(111)/I(200) reaches its maximum value indicating a strong left-angle 111 right-angle texture, while the impurity concentration and resisitivity are minimum. The correlation ...

1990-01-01

49

Deposition of Cu film on SiO sub 2 using a partially ionized beam  

Energy Technology Data Exchange (ETDEWEB)

Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO{sub 2} substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio {ital I}(111)/{ital I}(200) reaches its maximum value indicating a strong {l angle}111{r angle} texture, while the impurity concentration and resisitivity are minimum. ...

1990-05-01

50

Deposition of Cu film on SiO sub 2 using a partially ionized beam  

Science.gov (United States)

Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO{sub 2} substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio {ital I}(111)/{ital I}(200) reaches its maximum value indicating a strong {l angle}111{r angle} texture, while the impurity concentration and resisitivity are minimum. ...

1990-05-01

51

Grating-based X-ray phase imaging using multiline X-ray source  

International Nuclear Information System (INIS)

Differential phase-contrast X-ray imaging has been performed in a Talbot-Lau configuration, where a multiline X-ray source was used instead of a combination of a hard-X-ray multiple slit and a normal focus X-ray generator. When the multiple slit is used, a high aspect ratio structure is needed and slit width should be below 10 ?m for its function. The fabrication and use of such a multislit can be omitted using the presented configuration. The multiline X-ray source was developed by making grooves on a tungsten rotating anode, which was irradiated by an electron beam to generate X-rays. An array of 10?m line sources with a pitch of 30?m was formed and combined with a 4.5 ?m pitch phase grating and a 5.3 ?m pitch amplitude grating to generate differential phase contrast. With a total exposure time of 40 s, a differential phase image depicting ...

2009-07-01

52

Some physical considerations in whole skin electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

The short range of low-energy electrons has made them suitable for the treatment of skin lesions, especially when extensive areas must be irradiated with special considerations to save the normal underlying tissue. This report covers some salient features of total body electron irradiation: the construction of the large fields required, x-ray contamination levels, and multiple-field techniques. While the investigation is essentially experimental, we also indicate the results of calculations. We conclude most generally that treatment planning with whole skin irradiations can be as precise as with smaller fields.

1982-09-01

53

Broad-band hard X-ray reflectors  

DEFF Research Database (Denmark)

Interest in optics for hard X-ray broad-band application is growing. In this paper, we compare the hard X-ray (20-100 keV) reflectivity obtained with an energy-dispersive reflectometer, of a standard commercial gold thin-film with that of a 600 bilayer W/Si X-ray supermirror. The reflectivity of the multilayer is found to agree extraordinarily well with theory (assuming an interface roughness of 4.5 Angstrom), while the agreement for the gold film is less, The overall performance of the supermirror is superior to that of gold, extending the band of reflection at least a factor of 2.8 beyond that of the gold, Various other design options are discussed, and we conclude that continued interest in the X-ray supermirror for broad-band hard X-ray applications is warranted.

1997-01-01

54

Anode length optimization in a modified plasma focus device for optimal x-ray yields  

International Nuclear Information System (INIS)

The effect of anode length and operating gas pressure on the x-ray emission from a nitrogen-filling modified plasma focus device has been investigated. The time-resolved investigation of x ray was carried out by using a five-channel photodiode x-ray spectrometer. The maximum x-ray yield is seen to increase with the increase in the anode length from 110 to 125 mm. Further increase in the anode length to 130 mm causes the x-ray yields to decrease. The highest x-ray yield of 4.5 J into 4#pi# sr was found for 125 mm anode length, which is 0.2% of the input energy. The average x-ray photon energy was estimated by using half-value thickness method and found to be 8.4 keV. The electron temperature of the plasma was estimated to be around 3 keV by x-ray intensity ...

2006-01-01

55

Free-electron laser beam  

International Nuclear Information System (INIS)

The principle and history of free-electron laser (FEL), first evidenced in 1977, the relationship between FEL wavelength and output power, the high-power FEL driven by the superconducting linac, the X-ray FEL by the linac, and the medical use are described. FEL is the vacuum oscillator tube and essentially composed from the high-energy linac, undulator and light-resonator. It utilizes free electrons in the vacuum to generate the beam with wavelength ranging from microwave to gamma ray. The first high-power FEL developed in Japanese Atomic Energy Research Institute (JAERI) is based on the development of superconducting linac for oscillating the highest power beam. In the medical field, applications to excise brain tumors (in US) and to reconstruct experimentally blood vessels in the pig heart (in Gunma University) by lasing and laser coagulator are in progress with examinations to ...

2003-06-01

56

Soft X-ray holography of FIB nanostructured Co/Pt multilayers  

International Nuclear Information System (INIS)

Focused Ion Beam (FIB) milling is a powerful tool to produce ordered magnetic nanostructures. However, it is impossible to produce out-of-plane magnetized nanoscale structures from multilayer films by direct FIB writing. Co/Pt multilayers exhibit an out-of-plane easy axis due to strong perpendicular interface anisotropy. The interface contribution is known to be very sensitive to high energy ion irradiation. In case of 30 keV Ga ions it needs less than one ion per 100 surface atoms to destroy the perpendicular interface anisotropy. We demonstrate how this problem can be overcome by milling a Co/Pt multilayer, which has been deposited on a SiN membrane, from the rear side, through the SiN. The effect of the ions is determined as a function of applied dose utilizing the domain structure imaged by soft X-ray holography. When the magnetic material is removed we find only a very narrow range of destruction around the holes in ...

2009-03-22

57

Cross-sectional Specimen Preparation and Observation of a Plasma Sprayed Coating Using a Focused Ion Beam/Transmission Electron Microscopy System.  

Science.gov (United States)

A focused ion beam (FIB) technique was applied to cross-sectional specimen preparation to observe an interface between a plasma sprayed coating and an aluminum (Al) substrate by transmission electron microscopy (TEM). The surface of the sprayed coating film has a roughness of several tens of microns. Sputter rates for the coating film and the substrate are greatly different. The rough surface and the difference in sputter rate cause problems in making TEM specimens with smooth side walls. The top surface of the coating film was planerized by the FIB before fabricating the TEM specimen. The interfaces were investigated by TEM and energy-dispersive X-ray (EDX) analysis. The TEM observation revealed that there is a 10 nm thick amorphous layer at the interface between the coating film and substrate. The coating film consists of two kinds of sublayers with bright and dark contrast. The bright contrast sublayers were amorphous ...

2000-05-01

58

Charge redistribution in ion-beam-mixed Pd-Ag alloys  

Science.gov (United States)

Charge flow and valence/d-band behavior in ion-beam-mixed (IBM) Pd1-xAgx (x = 0.5-0.9) alloys have been studied by X-ray photoemission measurement of the valence bands and of core-level binding energy shifts and X-ray absorption near-edge structure. We correlated the observed Ag 3d5/2 core-level shifts in these IBM alloys, relative to the elemental Ag, with the White Line area changes at the Pd and Ag L3-edge to investigate the charge redistribution at the Ag site. The results indicate that there is a decrease in sp-like conduction electron and a negligible change in the number of d-electrons at the Ag site upon alloying. These results are in line with our previous results in which Pd gains d-charges and loses sp-type charges. This electron redistribution due to hybridization in the alloy leads small net charge transfer from the Ag site to the Pd site in accordance with electronegativity predictions. ...

1996-08-01

59

The evolution of x-ray binaries  

International Nuclear Information System (INIS)

These proceedings represent papers presented at the Astrophysics Conference in Maryland, USA. The topic of the Conference was the evolution of x-ray binaries and the papers encompass a wide range of subjects on x-ray astronomy. There were one hundred eighteen papers presented at the Conference and out of these three have been abstracted for the Energy Science and Technology database.

1993-10-11

60

X-ray generation by the Smith-Purcell effect  

International Nuclear Information System (INIS)

Smith-Purcell (S-P) radiation is produced when electrons graze the surface of a grating. Calculations based on the theory of diffraction radiation show that, given severe restrictions on e"--beam quality, S-P radiation is highly efficient. Efficient S-P x-ray generation requires relativistic e"- beams having a transverse momentum and dimension whose product approaches the Heisenberg uncertainty limit.

61

Radiotherapy for ocular lesions by electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Radiotherapy can be very significant as the treatment for ocular lesions, eyes need to be preserved as properly as possible on their functions and cosmetics. The application of conventional X ray therapy has been gradually abandoned as conventional X ray therapy ceased to be accepted as the general treatment for malignant tumors. Consequently the necessity of electron beam therapy has been rising even as the substituted method for conventional X ray therapy. The department of radiology of Gunma University was obliged to establish a new therapy for ocular lesions, and has been trying electron beam therapy since 1973. It is concluded that electron beam therapy is not at all inferior to conventional X ray therapy as reported above. Basic therapeutic methods for ...

1981-11-01

62

Electron beam, ion beam, X-ray optical techniques for fabricating surface-acoustic-wave and thin-film optical devices  

International Nuclear Information System (INIS)

Most surface-acoustic-wave and thin-film optical devices are made by the planar fabrication process. The exposure of the pattern in the polymer film is the first and most crucial step in ensuring desired device geometry, dimensional control, and freedom from pattern distortion. The methods of exposing the polymer film include: optical projection, conventional contact printing, conformable photomask contact printing, holographic recording, scanning electron beam lithography, projection electron lithography, and x-ray lithography. In this paper scanning electron beam lithography, conformable photomask contact printing, holographic recording, and x-ray lithography are discussed. In the last section, ion beam etching of relief structures is discussed.

63

Noise suppression in scatter correction for cone-beam CT  

UK PubMed Central (United Kingdom)

Scatter correction is crucial to the quality of reconstructed images in x-ray cone-beam computed tomography (CBCT). Most of existing scatter correction methods assume smooth scatter distributions. The...Full Text Available

2009-03-01

64

Recent progress in energy-filtered high energy X-ray photoemission electron microscopy using a Wien filter type energy analyzer  

International Nuclear Information System (INIS)

Energy-filtered X-ray photoemission electron microscopy (EXPEEM) is a microscopy technique which has the potential to provide surface chemical mapping during surface chemical processes on the nanometer scale. We studied the possibilities of EXPEEM using a Wien filter type energy analyzer in the high energy X-ray region above 1000 eV. We have successfully observed the EXPEEM images of Au islands on a Ta sheet using Au 3d_5_/_2 and Ta 3d_5_/_2 photoelectron peaks which were excited by 2380 eV X-rays emitted from an undulator (BL2A) at Photon Factory. Our recent efforts to improve the sensitivity of the Wien filter energy analyzer will also be discussed.

2004-10-15

65

PERFORMANCE-LIMITING DEFECTS IN CDZNTE DETECTORS.  

Energy Technology Data Exchange (ETDEWEB)

We studied the effects of small, <20 {micro}m, Te inclusions on the energy resolution of CdZnTe gamma-ray detectors using a highly collimated X-ray beam and gamma-rays, and modeled them via a simplified geometrical approach. Previous reports demonstrated that Te inclusions of about a few microns in diameter degraded the charge-transport properties and uniformity of CdZnTe detectors. The goal of this work was to understand the extent to which randomly distributed Te-rich inclusions affect the energy resolution of CZT detectors, and to define new steps to overcome their deleterious effects. We used a phenomenological model, which depends on several adjustable parameters, to reproduce the experimentally measured effects of inclusions on energy resolution. We also were able to hound the materials-related problem and predict the enhancement in performance expected by reducing the ...

2006-10-29

66

Measurement of the K{sub {beta}}/K{sub {alpha}} ratio for muon alpha sticking X-rays in muon catalyzed d-t fusion at the RIKEN-RAL Muon Facility  

Energy Technology Data Exchange (ETDEWEB)

At the RIKEN-RAL Muon Facility, {mu}{sup -} to {alpha} sticking K{sub {beta}} X-rays were observed for the first time taking advantage of the pulsed beam structure. The precision of the present measurements was insufficient to distinguish between theoretical models, however the observed K{sub {beta}}/K{sub {alpha}} X-ray intensity ratio tends to be smaller than most of these theoretical predictions.

1999-06-15

67

Emission Line Spectra in the Soft X-Ray Region 20-75 (Angstrom)  

Energy Technology Data Exchange (ETDEWEB)

As part of a project to complete a comprehensive catalogue of astrophysically relevant emission lines in support of new-generation X-ray observatories using the Lawrence Livermore electron beam ion traps EBIT-I and EBIT-II, we studied emission lines of argon and sulfur in the soft X-ray and extreme ultraviolet region. Here we present observations of Ar IX through Ar XVI and S VII through S XIV between 20 and 75 {angstrom} to illustrate our work.

2002-06-18

68

Estimation of X-rays dose in the crystals of final thickness  

International Nuclear Information System (INIS)

A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.

69

Miniature x-ray source  

Energy Technology Data Exchange (ETDEWEB)

A miniature x-ray source utilizing a hot filament cathode. The source has a millimeter scale size and is capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature source consists of a compact vacuum tube assembly containing the hot filament cathode, an anode, a high voltage feedthru for delivering high voltage to the cathode, a getter for maintaining high vacuum, a connector for initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is fabricated from highly x-ray transparent materials, such as sapphire, diamond, or boron nitride.

2000-01-01

70

X-ray production with sub-picosecond laser pulses  

Energy Technology Data Exchange (ETDEWEB)

The interaction of intense, sub-picosecond laser pulses with solid targets produces intense picosecond x-ray pulses. With focused laser pulses of several 10 {sup 18} W/cm{sup 2}, He-like and H-like line radiation from targets such as aluminum and silicon has been produced. The energy conversion efficiency from the laser pulse energy to the 1--2 keV line x-rays is nearly one percent. The duration of the line x-ray radiation is of the order of ten picoseconds, although this may be an upper estimate because of the temporal resolution of the x-ray streak camera. The spatial extent of the x-ray source region is only slightly larger than the laser focal spot, or about 10 {mu}m in diameter. With these characteristics, such x-ray sources emit an intensity of nearly 10{sup 14} W/cm{sup 2}. Experiments and modeling which led to ...

1993-12-31

71

Energetic electrons in impulsive and extended solar flares as deduced from flux correlations between hard X-rays and microwaves  

Energy Technology Data Exchange (ETDEWEB)

The peak flux relationship between hard X-rays and microwaves from solar flares is studied using about 400 events simultaneously recorded with the hard X-ray burst spectrometer on the SMM satellite and the Nobeyama 17 GHz radiometer. The data indicate that the hard X-ray and microwave peak fluxes correlate best for X-ray energies of less than about 80 keV for impulsive flares and greater than about 360 keV for extended flares. By postulating that electrons responsible for microwave emission at 17 GHz are those emitting hard X-rays at these photon energies, it is concluded that: (1) in impulsive flares, microwaves at about 20 GHz are emitted mainly by electrons of less than about 200 keV from a layer through which the electrons stream down into the thick-target hard X-ray source; and (2) in extended flares, microwaves are ...

1988-01-01

72

Target area chamber system design for the National Ignition Facility  

International Nuclear Information System (INIS)

The National Ignition Facility (NIF) is a proposed Department of Energy facility which will contribute to the resolution of important Defense Program and inertial fusion energy issues for energy production in the future. The NIF will consist of a laser system with 192 independent beamlets transported to a target chamber. The target chamber is a multi-purpose structure that provides the interface between the target and the laser optics. The chamber must be capable of achieving moderate vacuum levels in reasonable times; it must remain dimensionally stable within micron tolerances, provide support for the optics, diagnostics, and target positioner; it must minimize the debris from the x-ray and laser light environments; and it must be capable of supporting external neutron shielding. The chamber must also be fabricated from a low neutron activation material. The fusion reaction in the target gives off ...

1994-06-19

73

Linac Coherent Light Source Longitudinal Feedback Model  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL). To ensure the vitality of FEL lasing, it is critical to preserve the high quality of the electron beam during acceleration and compression. The peak current and final energy are very sensitive to system jitter. To minimize this sensitivity, a longitudinal feedback system on the bunch length and energy is required, together with other diagnostics and feedback systems (e.g., on transverse phase space). Here, we describe a simulation framework, which includes a realistic jitter model for the LCLS accelerator system, the RF acceleration, structure wakefield, and second order optics. Simulation results show that to meet the tight requirements set by the FEL, such a longitudinal feedback system is mandatory.

2005-06-15

74

Measurement of the L sub 2 - L sub 3 Coster-Kronig transition probability in Tm( Z =69)  

Energy Technology Data Exchange (ETDEWEB)

The {ital L}{sub 2}-{ital L}{sub 3} Coster-Kronig transition probability ({ital f}{sub 23}) in Tm was measured by multiparameter {ital K} versus {ital L} x-ray coincidence techniques. The Tm x rays were obtained from a radioactive source of {sup 169}Yb and were detected with cooled germanium and silicon detectors of high-energy resolution. Corrections were applied for the contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak and for the contribution of unresolved {ital L}{eta} x rays to the {ital L}{alpha}{sub 1,2} x-ray peak. The contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak was determined solely from the results of the coincidence measurements ...

1989-11-01

75

Measurement of the L sub 2 - L sub 3 Coster-Kronig transition probability in Tm( Z =69)  

Science.gov (United States)

The {ital L}{sub 2}-{ital L}{sub 3} Coster-Kronig transition probability ({ital f}{sub 23}) in Tm was measured by multiparameter {ital K} versus {ital L} x-ray coincidence techniques. The Tm x rays were obtained from a radioactive source of {sup 169}Yb and were detected with cooled germanium and silicon detectors of high-energy resolution. Corrections were applied for the contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak and for the contribution of unresolved {ital L}{eta} x rays to the {ital L}{alpha}{sub 1,2} x-ray peak. The contribution of {ital K}{alpha}{sub 1} x rays to the {ital K}{alpha}{sub 2} x-ray peak was determined solely from the results of the coincidence measurements ...

1989-11-01

76

Laser Assisted Emittance Exchange: Downsizing the X-ray Free Electron Laser  

Energy Technology Data Exchange (ETDEWEB)

A technique is proposed to generate electron beam with ultralow transverse emittance through laser assisted transverse-to-longitudinal emittance exchange. In the scheme a laser operating in the TEM10 mode is used to interact with the electron beam in a dispersive region and to initiate the emittance exchange. It is shown that with the proposed technique one can significantly downsize an x-ray free electron laser (FEL), which may greatly extend the availability of these light sources. A hard x-ray FEL operating at 1.5 {angstrom} with a saturation length within 30 meters using a 3.8 GeV electron beam is shown to be practically feasible.

2009-12-11

77

A soft x-ray free electron laser (FEL) using a two-beam elliptical pill-box wake-field cavity  

International Nuclear Information System (INIS)

Stimulated bremsstrahlung in an undulating electric field in the lasing beam direction (electric wiggler) was shown to be possible from the quantum- mechanical viewpoint. Herein, this possibility is scrutinized from the viewpoint of classical electrodynamics. It is found that if stimulated bremsstrahlung in a transverse undulating magnetic field (magnetic wiggler) occurs, stimulated bremsstrahlung in the electric wiggler must also occur. We further show that a free electron laser (FEL) using a magnetic wiggler to provide a catalyzer field for stimulated bremsstrahlung cannot serve as a practical FEL operating in the soft x-ray region from both theoretical and experimental viewpoints. On the other hand, the authors demonstrate that the FEL using a traveling wake field in a two-beam elliptical pill-box cavity is well suited as a source of coherent radiation in the soft x-ray region.

1988-01-14

78

3. Physical foundations and methodology of radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The physical foundations are described of radionuclide X-ray fluorescence analysis (RXFA) and the table shows the values of K- and L-absorption thresholds and the K- and L-line energies of elements. The calculation of the intensity of characteristic radiation during RXFA proceeds from relations derived for conventional X-ray fluorescence analysis. The choice of the radionuclide source is ruled by the nature of the analysed substance and the used detection technique. The diagram shows the areas of radionuclide sources and the energy of the fluorescence radiation of elements. The table shows the spectra of radionuclide sources suitable for the purposes of RXFA measured by semiconductor Si(Li) and Ge(Li) detectors. (ES).

1983-12-01

79

Direct patterning of gold oxide thin films by focused ion-beam irradiation  

International Nuclear Information System (INIS)

For direct writing of electrically conducting connections and areas into insulating gold oxide thin films a scanning Ar"+ laser beam and a 30 keV Ga"+ focused ion beam (FIB) have been used. The gold oxide films are prepared by magnetron sputtering under argon/oxygen plasma. The patterning of larger areas (dimension 10-100 #mu#m) has been carried out with the laser beam by local heating of the selected area above the decomposition temperature of AuO_x(130-150 C). For smaller dimensions (100 nm to 10 #mu#m) the FIB irradiation could be used. With both complementary methods a reduction of the sheet resistance by 6-7 orders of magnitude has been achieved in the irradiated regions (e.g. with FIB irradiation from 1.5 x 10"7#OMEGA#/#square# to approximately 6 #OMEGA#/#square#). The energy-dispersive X-ray analysis (EDX) show a considerably reduced oxygen content in the irradiated areas, ...

2000-09-01

80

Magnetospheric particle acceleration and X-ray emission of pulsars  

CERN Document Server

The available data on isolated X-ray pulsars, their wind nebulae, and the supernova remnants which are connected to some of these sources are analyzed. It is shown that electric fields of neutron stars tear off charged particles from the surface of neutron star and trigger the acceleration of particles. The charged particles are accelerated mainly in the field of magneto-dipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magneto-dipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.

2007-01-01

81

High-energy x-ray microscopy techniques for laser-fusion plasma research at the National Ignition Facility  

Energy Technology Data Exchange (ETDEWEB)

Multi-kilo-electron-volt x-ray microscopy will be an important laser-produced plasma diagnostic at future megajoule facilities such as the National Ignition Facility (NIF). However, laser energies and plasma characteristics imply that x-ray microscopy will be more challenging at NIF than at existing facilities. We use analytical estimates and numerical ray tracing to investigate several instrumentation options in detail, and we conclude that near-normal-incidence single spherical or toroidal crystals may offer the best general solution for high-energy x-ray microscopy at NIF and similar large facilities. Apertured Kirkpatrick{endash}Baez microscopes using multilayer mirrors may also be good options, particularly for applications requiring one-dimensional imaging over narrow fields of view. {copyright} 1998 Optical Society of America

1998-04-01

82

Acceleration of particles in pulsar magnetosphere and the X-ray radiation  

CERN Document Server

The available data of single X-ray pulsars, their wind nebulae, and the SNRs which are connected to some of these sources are analysed. It is shown that electric field intensity of neutron stars tears off charged particles from the surface of neutron star and triggers the acceleration of particles. The charged particles are accelerated mainly in the field of magnetodipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magnetodipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.

2004-01-01

83

Lung dose calculations at kilovoltage x-ray energies using a model-based treatment planning system  

International Nuclear Information System (INIS)

The determination of the dose to organs from diagnostic x rays has become important because of reports of radiation injury to patients from fluoroscopically guided interventional procedures. We have modified a convolution/superposition-based treatment planning system to compute the dose distribution for kilovoltage beams. We computed lung doses using this system and compared them to those calculated using the CDI3 organ dose calculation program. We also computed average lung doses from a simulated radiofrequency ablation procedure and compared our results to published doses for a similar procedure. Doses calculated using this system were an average of 20% lower for AP beams and 7% higher for PA beams than those obtained using CDI3. The ratio of the average dose to the lungs to the skin dose from the simulated ablation procedure ranged from 25% higher to 15% lower than that ...

2001-02-01

84

Comparison of the radiobiological effect of carbon ion beam therapy and conventional radiation therapy on cervical cancer  

International Nuclear Information System (INIS)

Little clinical evidence has been provided to show the minimization of radiation resistance of tumors using high linear energy transfer radiation. We therefore investigated the radiobiological and molecular pathological aspects of carbon beam therapy. A total of 27 patients with squamous cell carcinoma (SCC) of the cervix were treated using a carbon beam and 50 control patients with SCC of the cervix using a photon beam. The expression of Ki-67, p53, and p27 proteins before radiotherapy and 5 and 15 days after therapy initiation were investigated using immunohistochemistry. Similar changes were observed in Ki-67 labeling index (LI) and p53 LI during carbon and photon beam therapies. However, for carbon beam therapy, the mean p27 LI significantly decreased from 25.2% before treatment to 18.6% on the 5th day after treatment initiation, followed by a significant ...

2008-09-01

85

Is the Ksub(#beta#)/Ksub(#alpha#) X-ray intensity ratio dependent upon the energy of an inducing proton  

International Nuclear Information System (INIS)

Ksub(#beta#)/Ksub(#alpha#) X-ray intensity ratios have been measured for various elements between Z = 29 and Z = 79 for incident proton energies of 23.6, 32.1 and 43.6 MeV. The results yield no evidence for a variation in ratio with particle energy. (orig.).

1980-01-01

86

The duke XUV FEL storage ring facility  

Energy Technology Data Exchange (ETDEWEB)

In this paper we present status and developments of the Duke storage ring facility. The Duke storage ring facility provides the unique combination of phase-locked light sources ranging from high power OK-4 XUV FEL to quasimonochromatic {gamma}-ray beam and IR/X-ray spontaneous radiation. The XUV OK-4 FEL, which is collaborative project with BlNP, Novosibirsk, is in operation since November, 1996. The OK-4 UV FEL is also used for production of nearly monochromatic {gamma}-ray s with tunable energy. We present the results of UV lasing with the OK4 FEL and selected results of its applications. We will discuss our future plans for extension of this source and status of the construction of dedicated used facility adjacent to the FEL building. (author)

1998-11-01

87

Adhesion studies of Au films on GaAs using ion-assisted deposition techniques  

International Nuclear Information System (INIS)

This paper reports on a series of experiments performed to examine the ability of ion beam assisted thermal deposition to produce good adhesion of Au metallization on GaAs left-angle 100 right-angle substrates. A study of the influence of Ar ion-assisted thermal deposition of the Au films as well as in situ pre-sputtering of the GaAs surface with low-energy Ar ions prior to thermal deposition, shows that strong adhesion can be achieved without resorting to chemical cleaning. The substrate temperature and the relative flux of Ar ions to incident Au atoms were varied in order to correlate these parameters with film adhesion. The interfaces of films processed under these various conditions were examined by XTEM, RBS and XPS. Orientation texture was studied by x-ray diffraction (XRD).

88

A proposed linac cavity rf drive system for the Los Alamos extreme ultraviolet free-electron laser  

Energy Technology Data Exchange (ETDEWEB)

Since 1979, scientists and engineers at the Los Alamos National Laboratory have designed, constructed, and operated a radio-frequency (RF) linac free-electron laser (FEL) at wavelengths from 9 to 45 /mu/m. Coupled with success of other research centers investigating wavelengths from the visible to far-infrared, Los Alamos is now proposing a vacuum-ultraviolet and soft x-ray (referred to henceforth as extreme ultraviolet, (XUV)) FEL oscillator/Self-Amplified Spontaneous Emission amplifier with beam energies ranging from 100 MeV to 1 GeV. This paper will focus on the first milestone of the proposed Los Alamos XUV project, i.e., a 250-MeV linac with approximately 50 mA of average current, producing photons with wavelengths below 1000 /angstrom/. 3 refs., 3 figs.

1989-01-01

89

Fundamental limits on beam stability at the advanced photon source  

International Nuclear Information System (INIS)

Orbit correction is now routinely performed at the few-micron level in the Advanced Photon Source (APS) storage ring. Three diagnostics are presently in use to measure and control both AC and DC orbit motions: broad-band turn-by-turn rf beam position monitors (BPMs), narrow-band switched heterodyne receivers, and photoemission-style x-ray beam position monitors. Each type of diagnostic has its own set of systematic error effects that place limits on the ultimate pointing stability of x-ray beams supplied to users at the APS. Limiting sources of beam motion at present are magnet power supply noise, girder vibration, and thermal timescale vacuum chamber and girder motion. This paper will investigate the present limitations on orbit correction, and will delve into the upgrades necessary to achieve true sub-micron beam stability.

1998-12-10

90

Photon-induced L-shell x-ray intensity ratio for elements with 73 #<=# Z #<=#83 in the energy range 17 #<=# E #<=# 47 keV  

International Nuclear Information System (INIS)

The L-shell x-ray intensity ratios I(L_#beta#)/I(L_#alpha#) and I(L_#gamma#)/I(L_a_l_p_h_a) for elements with 73 #<=# Z #<=# 83 have been measured at photon incident energies of 17.8, 25.8 and 46.9 keV. The emitted x-rays were measured with a Si(Li) detector system. The results for Re, Pt and Tl are being reported for the first time. A comparison is made of the experimental results with the calculated values obtained by using the theoretical x-ray emission rates, subshell ionisation cross sections, subshell fluorescence yields and Coster-Kronig transition probabilities. The experimental results are in reasonable agreement with the theoretical values. (author).

1988-01-01

91

Exact and variational calculations of eigenmodes for three-dimensional free electron laser interaction with a warm electron beam  

International Nuclear Information System (INIS)

I present an exact calculation of free-electron-laser (FEL) eigenmodes (fundamental as well as higher order modes) in the exponential-gain regime. These eigenmodes specify transverse profiles and exponential growth rates of the laser field, and they are self-consistent solutions of the coupled Maxwell-Vlasov equations describing the FEL interaction taking into account the effects due to energy spread, emittance and betatron oscillations of the electron beam, and diffraction and guiding of the laser field. The unperturbed electron distribution is assumed to be of Gaussian shape in four dimensional transverse phase space and in the energy variable, but uniform in longitudinal coordinate. The focusing of the electron beam is assumed to be matched to the natural wiggler focusing in both transverse planes. With these assumptions the eigenvalue problem can be reduced to a numerically manageable integral ...

1995-08-21

92

Measurement of M shell X-ray production cross sections and fluorescence yields for the elements in the atomic range 70#<=#Z#<=#92 at 5.96 keV  

International Nuclear Information System (INIS)

Total M X-ray cross sections for 12 elements in atomic range 70#<=#Z#<=#92 were measured at 5.96 keV Mn K X-ray photon energy. The average M shell fluorescence yields (anti #omega#_M) of these elements have also been observed using the presently measured cross section values and the theoretical M shell photoionisation cross section values. (orig.).

93

L-subshell and total M-shell X-ray production cross sections of Ta, W, Pt, Au, Pb and Bi by 0.7-2.4 MeV protons  

International Nuclear Information System (INIS)

The L-subshell and total M-shell X-ray production cross sections of Ta, W, Pt, Au, Pb and Bi have been measured by protons of energy between 0.7 and 2.4 MeV. The obtained results for X-ray production cross sections have been compared with the existing experimental data, prediction of the ECPSSR theory and also with fitted empirical cross sections of Strivay and Weber.

2006-06-01

94

Operation of beam line facilities for real-time x-ray studies at Sector 7 of the advanced photon source. Final Report  

Energy Technology Data Exchange (ETDEWEB)

This Final Report documents the research accomplishments achieved in the first phase of operations of a new Advanced Photon Source beam line (7-ID MHATT-CAT) dedicated to real-time x-ray studies. The period covered by this report covers the establishment of a world-class facility for time-dependent x-ray studies of materials. During this period many new and innovative research programs were initiated at Sector 7 with support of this grant, most notably using a combination of ultrafast lasers and pulsed synchrotron radiation. This work initiated a new frontier of materials research: namely, the study of the dynamics of materials under extreme conditions of high intensity impulsive laser irradiation.

2003-09-10

95

A somatic dose index for diagnostic radiology  

International Nuclear Information System (INIS)

Irradiation of the human body in diagnostic X-ray procedures results in different absorbed doses in the various body organs. A somatic dose index in formulated by applying the relative sensitivity of the human to each of the most important somatic effects and utilizing the absorbed dose in the affected organs. This quantity is used to convey a cumulative somatic impact and is computed for common radiographic views in diagnostic radiology as a function of beam quality for a nominal IR entrance exposure. Using typical X-ray beam qualities and exposures, the frequency of the various radiographic views that make up an examination and the frequencies of the various examinations in the national population, illustrative examples of the application of the somatic dose index are presented. (author).

1978-01-01

96

A water calorimeter for high energy x-rays and electrons  

CERN Document Server

The current primary standards at NPL for the measurement of absorbed dose to water in high energy photon and electron beams are graphite calorimeters. However, the quantity of interest in radiation dosimetry is absorbed dose to water. Therefore, a new absorbed dose to water standard based on water calorimetry has been developed for use in high energy photon and electron beams. The calorimeter operates at 4 deg C, with temperature control being provided by liquid cooling. The sealed glass inner vessel of the calorimeter was designed to minimise the effect of non-water materials on the measurement of absorbed dose. The temperature sensing thermistor probes were designed and constructed so that glass is the only material in contact with high purity water inside the vessel. Initial measurements of absorbed dose to water made in 6, 10, and 19 MV photons, and 16 MeV electrons agreed, within the measurement ...

2000-01-01

97

Analysis of titanium and zirconium in red mud with energy dispersive x-ray spectrometry  

Energy Technology Data Exchange (ETDEWEB)

An energy dispersive x-ray fluorescence technique was used for the determination of Titanium (Ti) and Zirconium (Zr) in red mud by using a standard addition method. An annular {sup 241}Am source is employed for excitation of K shells of elements. 13 refs., 2 figs., 1 tab.

1996-11-01

98

Correlation between ion beam parameters and physical characteristics of nanostructures fabricated by focused ion beam  

International Nuclear Information System (INIS)

We report a study of the physical characteristics of the pillars of C, Pt and W grown by 10-30 keV Ga focused ion beam (FIB) as a function of Ga ion flux, and present a quantitative analysis of the elements using energy-dispersive analysis of X-rays (EDAX). All the FIB grown pillars exhibit a rough morphology with whisker like protrusions on the cylindrical surface and broadening of the base as compared to the nominal size. For a constant fluence, the height of the pillar initially increases and then reduces after going through a maximum as a function of ion flux in all the cases. The compositional analysis shows good metallic quality for Pt structures but reveals significant contamination of Ga in C and Ga and C in W structures at higher ion fluxes. Explanation to all these observations has been sought in the light of secondary ion and electron effects and the different processes involved which lead to the FIB induced ...

2008-04-01

99

AECL IMPELA electron beam industrial irradiators  

International Nuclear Information System (INIS)

A family of industrial irradiators is being developed by AECL to cover an electron-beam energy range from 5 to 18 MeV at beam powers between 20 and 250 kW. The IMPELA family of irradiators is designed for push button, reliable operation. The major irradiator components are modular, allowing for later upgrades to meet increased demands in either electron or X-ray mode. Interface between the control system, irradiator availability and dose quality assurance is in conformance with the most demanding specifications. The IMPELA irradiators use a klystron-driven, standing-wave, L-band accelerator structure with direct injection from a rugged, triode electron gun. Direct control of the accelerating field during the beam pulse ensures constant output beam energy, independent of beam power. The first member of the family, the ...

100

X-ray exposure in the teaching of science at junior and senior high schools  

Energy Technology Data Exchange (ETDEWEB)

A significant amount of X-rays were detected as a leakage from some of the Crooke`s tubes which were used in the teaching of science at junior and senior high schools in Japan. We measured the leaked dose of X-rays from the Crooke`s tubes with ionizing chambers, film badges and TLDs. The maximum leaked dose at 5cm distance from those tubes was estimated 143mSv/h. The effective energy of leaked X-rays was 19.3keV. The maximum dose of students exposed during the teaching of science were estimated 0.15mSv per experiment, which exceeded the value recommended in the ICRP publication 36. (author)

1995-10-01

101

Particle and X-ray damage in pn-CCDs  

Energy Technology Data Exchange (ETDEWEB)

The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.

2000-01-11

102

Measurements and calculations of M-shell X-ray production in Er, Yb and Lu by 0.75-6 MeV He ions  

Energy Technology Data Exchange (ETDEWEB)

M-shell X-ray production cross sections for the light rare-earth elements of {sup 68}Er, {sup 7}Yb and {sup 71}Lu have been measured for incident {sup 4}He{sup +} ions in the energy range from 0.75 to 6 MeV. The measured X-ray production cross sections are compared to the predictions of the First Born approximation, the ECPSSR theory and the ECUSAR theory. A comparison of the ytterbium M-shell X-ray production cross sections with these theories is made for two different sets of fluorescence yields and Coster-Kronig factors that are further modified for multiple ionization.

2005-12-15

103

Use of a convolution/superposition-based treatment planning system for dose calculations in the kilovoltage energy range  

International Nuclear Information System (INIS)

A number of procedures in diagnostic radiology and cardiology make use of long exposures to x-rays from fluoroscopy units. Although numerous studies have been performed to measure or calculate skin dose from these procedures, there have only been a handful of studies to determine the dose to the other organs. This thesis was focused on devising a method to calculate the absorbed dose to underlying tissues and organs. The work was performed in several stages. First, a commercial convolution/superposition-based treatment planning system used in radiation oncology was modified and complemented to make it usable with the low energies of x-rays used in diagnostic radiology. This required generation of energy deposition kernels in the kilovoltage energy range. The kernels were generated using the EGS4 Monte Carlo system of codes and added to the treatment planning system. The treatment ...

2001-03-01

104

Performance of Brazilian thermoluminescent CaSO{sub 4}: Dy pellets in standard diagnostic radiology beams  

Energy Technology Data Exchange (ETDEWEB)

The high sensitivity of CaSO{sub 4}: Dy as a thermoluminescent material is a great advantage when dealing with low dose levels, as in diagnostic radiology procedures. However, these kinds of dosemeters present a high energy dependence that must be precisely determined in the energy range of interest. Dosimetric pellets of CaSO{sub 4}: Dy are produced at IPEN since the end of the 80 Th decade. These pellets are produced in three forms: conventional CaSO{sub 4}: Dy (50 mg); thin CaSO{sub 4}: Dy (20 mg) and CaSO{sub 4}: Dy + 10% C (20 mg). The main applications of these dosemeters are in personal and environmental dosimetry. In this study, CaSO{sub 4}: Dy pellets produced at IPEN were evaluated in diagnostic radiology standard beams. These qualities are based on the IEC 61267 standard, and they were established at an industrial X-ray system Pantak/Seifert, model ISOVOLT 160HS. Former studies evaluated ...

2006-07-01

105

Bendable Focusing X-Ray Optics for the ALS and the LCLS/FEL: Design, Metrology, and Performance  

Energy Technology Data Exchange (ETDEWEB)

We review the recent development of bendable x-ray optics used for focusing of beams of soft and hard x-rays at the Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory and at the Linac Coherent Light Source (LCLS) x-ray free electron laser (FEL) at the Stanford Linear Accelerator Center (SLAC) National Accelerator Laboratory. For simultaneous focusing in the tangential and sagittal directions, two elliptically cylindrical reflecting elements, a Kirkpatrick-Baez (KB) pair, are used. Because fabrication of elliptical surfaces is complicated, the cost of directly fabricated tangential elliptical cylinders is often prohibitive. Moreover, such optics cannot be easily readjusted for use in multiple, different experimental arrangements, e.g. at different focal distances. This is in contrast to flat optics that are simpler to manufacture and easier to measure by conventional interferometry. The ...

2010-06-02

106

Kinetic investigations of graft copolymerization of sodium styrene sulfonate onto electron beam irradiated poly(vinylidene fluoride) films  

Energy Technology Data Exchange (ETDEWEB)

Graft copolymerization of sodium styrene sulfonate (SSS) onto electron beam (EB) irradiated poly(vinylidene fluoride) (PVDF) films was investigated to find out a simple preparation process for sulfonic acid proton exchange membranes with respect to monomer concentration, absorbed dose, temperature, film thickness and storage time. The reaction order of the monomer concentration and absorbed dose of grafting was found to be 2.84 and 1.20, respectively. The overall activation energy for graft copolymerization reaction was calculated to be 11.36 kJ/mol. The initial rate of grafting was found to decrease with an increase in the film thickness. The trapped radicals in the irradiated PVDF films remained effective in initiating the reaction without considerable loss in grafting level up to 180 days, when stored under -60 {sup o}C. The presence and distribution of polystyrene sulfonate grafts in the obtained membranes were observed by Fourier transform ...

2011-01-15

107

Using a photon phase-space source for convolution/superposition dose calculations in radiation therapy  

International Nuclear Information System (INIS)

For a given linac design, the dosimetric characteristics of a photon beam are determined uniquely by the energy and radial distributions of the electron beam striking the x-ray target. However, in the usual commissioning of a beam from measured data, a large number of variables can be independently tuned, making it difficult to derive a unique and self-consistent beam model. For example, the measured dosimetric penumbra in water may be attributed in various proportions to the lateral secondary electron range, the focal spot size and the transmission through the tips of a non-divergent collimator; the head-scatter component in the tails of the transverse profiles may not be easy to resolve from phantom scatter and head leakage; and the head-scatter tails corresponding to a certain extra-focal source model may not agree self-consistently with in-air output factors ...

2005-09-07

108

Accelerators for proton and heavy ion radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

The construction of Heavy Ion Medical Accelerator in Chiba (HIMAC) at the National Institute of Radiological Sciences was completed in December 1993. HIMAC consists of an injector linac, two synchrotron rings, a high energy beam transport system and a beam irradiation system. Its accelerator parameters are based on the medical requirement, and helium, carbon, neon, silicon and argon were selected as the accelerated ion species. It has 3 therapy rooms (A{approx}C). Room A has a vertical irradiation system, Room C horizontal and Room B both vertical and horizontal. Two rings can supply beams independently to the vertical and horizontal irradiation systems. Clinical trial started on June 21 1994, after several basic biological and physics experiments lasting about 2 months. Cancer is the top cause of death in Japan since 1981, and people expect good treatment results at HIMAC. Proton and heavy ion ...

1995-03-01

109

Experimental Evaluation And Simulation Of Multi-pixel Cadmium-zinc-telluride Hard-x-ray Detectors  

CERN Document Server

This dissertation describes the evaluation of many-pixel Cadmium-Zinc-Telluride (CdZnTe) hard-X-ray detectors for future use with the High Energy Replicated Optics (HERO) telescope being developed at Marshall Space Flight Center. The detector requirements for the HERO application are good energy resolution (sufficient to resolve cyclotron features and nuclear lines), spatial resolution of ∼200 μm, minimal charge loss of absorbed X rays, and minimal sensitivity to the background environment. This research concentrates on assessing the suitability of these detectors for the focus of HERO, and includes the development of a simulation of the physics involved in an X-ray-detector interaction, a study of the intrinsic material properties, measurements with prototype detectors such as the energy and spatial resolution, charge loss, ...

2004-01-01

110

Effects of Tapered Betafunction in the LCLS Undulators  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) is an X-ray free-electron laser (FEL) project based on the SLAC linac [1]. With its nominal set of electron beam, focusing and undulator parameters, it is designed to achieve SASE saturation at an undulator length of about 100 m with an average power of 10 GW. In order to keep the electron beam focused in the undulators, a FODO lattice is integrated along the entire length of the undulators. Nominally, the quadrupole strengths are chosen to produce nearly constant betafunction and beam size along the undulator, optimized for the FEL interaction in the exponential growth regime. Since these quadrupoles are electromagnetic, it is possible to adjust the individual quadrupole strength to vary the betafunction and the beam size along the undulator, tailoring the FEL interaction in the start-up and the saturation regimes. In this paper, we present ...

2005-09-30

111

Nanofocusing refractive X-ray lenses  

Energy Technology Data Exchange (ETDEWEB)

This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small ...

2010-02-05

112

Chamber technology concepts for inertial fusion energy: Three recent examples  

Energy Technology Data Exchange (ETDEWEB)

The most serious challenges in the design of chambers for inertial fusion energy (IFE) are 1) protecting the first wall from fusion energy pulses on the order of several hundred megajoules released in the form of x rays, target debris, and high energy neutrons, and 2) operating the chamber at a pulse repetition rate of 5-10 Hz (i.e., re-establishing, the wall protection and chamber conditions needed for beam propagation to the target between pulses). In meeting these challenges, designers have capitalized on the ability to separate the fusion burn physics from the geometry and environment of the fusion chamber. Most recent conceptual designs use gases or flowing liquids inside the chamber. Thin liquid layers of molten salt or metal and low pressure, high-Z gases can protect the first wall from x rays and target debris, ...

1997-02-27

113

M shell x-ray emission in Pb, Th and U due to L_3 to M sub shell transfer of vacancies  

International Nuclear Information System (INIS)

M shell x-ray production cross sections in thick targets of Pb, Th and U by K x-rays of Rb, Nb and Mo respectively have been measured. As the incident K x-ray energies are above the L_3 edge but below L_2 edge energies of the respective target elements under reference, the M x-rays are produced not only due to direct interaction of incident photons with M shell electrons but also due to the shift of the L_3 subshell vacancies to the M shell. The experiment has been performed using a double reflection geometrical setup with a 1 Curie"2"4"1Am gamma ray source and a Si (Li) x-ray spectrometer. The measured values have been compared with those calculated using known values of M and L_3 subshell photoionisation cross sections and fluorescence yields etc., wherever possible. The component of the percentage contribution due to shift of L_3 subshell ...

114

The optimum modification of energy spectra using FFT convolution/multigrid superposition algorithm on the focus radiation treatment system  

International Nuclear Information System (INIS)

In the convolution/superposition algorithm, the energy spectrum should be modified to make the reconstructed dose distribution consistent with the measured dose distribution. The energy spectrum, which gives the best agreement, is not determined uniquely depending on the reconstruction procedure. In this report, the effects of the characteristics of the energy spectrum on the calculation accuracy are evaluated by comparing the percentage depth dose (PDD) and beam profiles for the reference energy spectrum with those calculated for the modified spectrum in order to optimize the energy spectrum modification procedure when 4 and 10 MV X-ray beams are used. Decreasing the number of energy bins brought a larger decrease rate in the computation accuracy than a decrease rate in computation time. Further, ...

2003-06-01

115

X-ray and HeI 1.0830 mu emission from protostellar jets  

CERN Document Server

Context. The high energies of protostellar jets, implied by recent observations of X-rays from such flows, came very much as a surprise. Inferred shock velocities are considerably higher than what was previously known, hence putting even larger energy demands on the driving sources of the jets. The statistics of X-ray emitting jets are still poor, yet a few cases exist which seem to imply a correlation between the presence of HeI 1.0830 mu emission and X-ray radiation in a given source. Aims. This tentative correlation needs confirmation and explanation. If the jet regions of HeI 1.0830 mu emission are closely associated with those producing X-rays, high resolution infared spectroscopy can be used to observationally study the velocity fields in the hot plasma regions of the jets. This would provide the necessary evidence to test and further develop theoretical ...

2006-01-01

116

The intriguing nature of the high energy gamma ray source XSSJ12270-4859  

CERN Document Server

The nature of the hard X-ray source XSSJ12270-4859 is still unclear though it was claimed to be a magnetic Cataclysmic Variable. We here present a broad-band X-ray and gamma ray study based on a recent XMM-Newton observation and archival INTEGRAL and RXTE data. From the Fermi/LAT 1-year point source catalogue, we tentatively associate XSSJ12270-4859 with 1FGLJ1227.9-4852, a source of high energy gamma rays with emission up to 10GeV. We complement the study with UV photometry from XMM-Newton and ground-based optical and near-IR photometry. The X-ray emission is highly variable showing flares and intensity dips. The X-ray flares consist of flare-dip pairs. Flares are also detected in the UV range but not the dips. Aperiodic dipping behaviour is also observed during X-ray quiescence but not in the UV. The 0.2-100keV spectrum is featureless and described by a power ...

2010-01-01

117

A radionuclide analyzer of total sulfur in coal  

International Nuclear Information System (INIS)

The devised radionuclide analyzer for the determination of total sulfur in coal includes two radionuclide sources with different energies, which are accommodated in collimators fitted with adjustable diaphramgs. The sample compartment is located between the two sources. Moreover, an X-ray fluorescence standard can be slid into the sample compartment. A proportional detector for X-ray fluorescence and scattered gamma radiation is located off the sample compartment. The input of the proportional detector is interfaced to the output of a high-voltage supply, the output, to the information input of a control-and-evaluation unit. One of the control outputs of the control-and-evaluation unit is connected to the input of the sliding mechanism for the X-ray fluorescence standard. This arrangement enables automatic energy calibration of the analyzer. The analyzer can measure not only total ...

1987-05-13

118

Observed energy dependence of Fano factor in silicon at hard X-ray energies  

Energy Technology Data Exchange (ETDEWEB)

An experimental evaluation of the Fano factor F in silicon at hard X-ray energies (5.9-136.5 keV) has been performed by means of a low-noise, high charge collection efficiency silicon drift detector with on-chip electronics. A dependence of F from the detector temperature as well as from the energy of the X-ray photons has been found. Assuming a pair creation energy equal to 3.64 eV, at +20 deg. C the F factor was observed to vary from 0.124{+-}0.006 at 5.9 keV up to 0.159{+-}0.002 at 122 keV. At -35 deg. C, the change of F with respect to the photon energy was less remarkable but nevertheless statistically significant, from 0.123{+-}0.002 at 5.9 keV up to 0.134{+-}0.001 at 122 keV. To our knowledge, the present results represent the first experimental evidence of an energy dependence of the Fano factor in silicon at hard ...

1999-03-01

119

Study on wavelength shortening and upgrading of the free electron laser (FEL)  

International Nuclear Information System (INIS)

This study is a task of ''Comprehensive study'' in ''nuclear energy basic technology research'', which is promoted under cooperation of four research institutes. The Electrotechnical Laboratory conducted, in 1991 in the first period of colaboration, on successful oscillation at visible region (598 nm) as the first case in Japan, construction of small type accumulation ring NIJI-IV for FEL, successful oscillation of visible range from 595 to 488 nm by installing optical krystron with maximum frequency in the world, and successful emittance lowering of accumulation beam by wide improvement of the ring. In the optical resonator, studies on minute loss measuring technique and on recovery from mirror deterioration were promoted. In the second period started from fiscal year of 1994, studies on FEL oscillation technique in short wavelength and upgrading of FEL corresponding to a frontier area were started, to succeed an oscillation experiment at 350 ...

120

Ozone production at the National Synchrotron Light Source  

International Nuclear Information System (INIS)

Ozone production by synchrotron radiation as a function of power density in air was investigated using a white beam at the BNL National Synchrotron Light Source (NSLS) x-ray ring. Power densities were calculated from the energy spectrum at 2.52 GeV. Ozone concentrations in small beam pipes were measured for power densities between I = 10"1"2 and 10"1"5 eV . cm"-"3 . sec"-"1. The measured ozone half-life was 37 +- 2 min. The measured G-value was 2.69 +- 0.14 mol/100 eV and the ozone destruction factor k was less than 7 x 10"-"1"9 cm"3 . eV"-"1. The random uncertainties stated are approximately one standard error. The large departure of the values for G and k from previous values suggest that some undiscovered systematic error may exist in the experiment. Ozone concentration in excess of the 0.1 ppM ACGIH TLV can be generated in the experimental hutches but can readily be controlled. Industrial hygiene ...

1998-09-20

121

Ozone production at NSLS  

International Nuclear Information System (INIS)

Ozone production by synchrotron radiation as a function of power density in air was investigated using a white beam at the BNL National Synchrotron Light Source (NSLS) x-ray ring. Power densities were calculated from the energy spectrum at 2.52 GeV. Ozone concentrations in small beam pipes were measured for power densities between I = 10/sup 12/ and 10/sup 15/ eV/sup . /cm/sup -3 . /sec/sup -1/. The measured ozone half-life was 37+-2 min. The measured G-value was 2.69+-0.14 mol/100 eV and the ozone destruction factor k was less than 5 x 10/sup -19/cm/sup 3//eV. The random uncertainties stated are approximately one standard error. The large departure of the values for G and k from previous values suggest that some undiscovered systematic error may exist in the experiment. Ozone concentration in excess of the 0.1 ppm ACGIH TLV can be generated in the experimental hutches but can readily be controlled. ...

122

Microstructural observation of focused ion beam modification of Ni silicides/Si thin films  

International Nuclear Information System (INIS)

Focused ion beam (FIB) irradiation of a thin Ni_2Si layer deposited on a Si substrate was carried out and studied using an in-situ transmission electron microscope (in-situ TEM). Square areas on sides of 4 by 4 and 9 by 9 microm were patterned at room temperature with a 25 keV Ga"+-FIB attached to the TEM. The structural changes of the films indicate a uniform milling, sputtering of the Ni_2Si layer and the damage introducing to the Si substrate. Annealing at 673 K results in the change of the Ni_2Si layer into an epitaxial NiSi_2 layer outside the FIB irradiated area, but several precipitates appear around the treated area. Precipitates was analyzed by energy dispersive X-ray spectroscopy (EDS). Larger amount of Ni than the surrounding matrix was found in precipitates. Selected area diffraction (SAD) patterns of the precipitates and the corresponding dark field images imply the formation of a Ni rich silicide. The relation ...

1996-12-02

123

Provenance study of excavated pottery from Beirut using PIXE cluster analysis  

International Nuclear Information System (INIS)

The study of imported ceramics found in Beirut and suspected to belong to north Syrian products will provide key evidence for the roles in trade of the various postulated centers in northern Syria and northern Lebanon. It is proposed that a comprehensive range of likely north Syrian products imported to Beirut will be chemically analyzed by PIXE (proton induced X-ray emission) in order to characterize, compare and isolate the various regional production centers that supplied the city from the Persian to Byzantine periods. In this work, we were mainly focusing on the characterization of Amrit products, by using 3 MeV proton beam and Al funny filter, as X-ray absorber.

2006-08-01

124

Measurement of AlP/GaP (001) heterojunction band offsets by x-ray photoemission spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

X-ray photoemission spectroscopy has been used to measure the valence band offset {Delta}E{sub v} for the AlP/GaP (001) heterojunction interface. The heterojunction samples were prepared by molecular-beam epitaxy. A value of {triangle}E{sub v}=0.43 eV is obtained (staggered band alignment, with AlP valence band below that of GaP). 24 refs., 8 figs., 1 tab.

1993-07-01

125

Core localized toroidal Alfven eigenmodes destabilized by energetic ions in the CHS heliotron/torsatron  

Energy Technology Data Exchange (ETDEWEB)

Toroidal Alfven eigenmodes (TAE) destabilized by the pressure gradient of energetic alpha particles may expel the alpha particles before thermalization. TAE is important for tokamaks, and for helical systems (stellarators) as well. In CHS (compact helical system) TAE localized in the plasma core are destabilized when the plasma current is induced by co-injection of neutral beams. The observed TAE exhibits a ballooning nature. The internal structure of TAE was measured with a soft X-ray detector. The soft X-ray fluctuations level for TAE is too low to obtain the radial profiles of fluctuation intensities. (Tanaka, M.)

1999-09-01

126

X-dosimetry of Tl(InS_2)_1_-_x(FeSe_2)_x single crystals  

International Nuclear Information System (INIS)

Tl(InS_2)_1_-_x(FeSe_2)_x single crystals (where x=0; 0.001; 0.005; 0.01 and 0.015) were grown by the Bridgman-Stockbarger method. Obtained single crystals were crystallized in monoclinic structure. The present paper deals with experimental results relative to X-ray dosimetric characteristics of the Tl(InS_2)_1_-_x(FeSe_2)_x solid solutions at 300 K. Installation URS-55a was the source of radiation. X-ray radiation dose (E) falling on the crystals is measured by the crystalline X-ray dosimeter DRGZ-02. The value of X-ray conductivity coefficient K_#sigma# characterising X-ray sensitivity is defined as K_#sigma#= (#sigma#_E-#sigma#_0)/E#sigma#_0. where #sigma#_E is conductivity under the effect of X-ray radiation by intensity E, #sigma#_0 is conductivity in the lack of radiation. Comparing X-ray dosimetric characteristics of TlInS_2 and ...

2003-09-15

127

Total M shell X-ray production cross sections and average fluorescence yields in 11 elements from Tm to U at photon energy of 5.96 keV  

International Nuclear Information System (INIS)

Total M shell X-ray production cross section for 11 elements with 69 #<=# Z #<=# 92 have been measured using an incident photon energy of 5.96 keV. Measurements have been performed using an "5"5Fe annular source and a Si(Li) detector. Average M shell fluorescence yield at each incident photon energy has been deduced, using the experimental total M X-ray production cross section and theoretical M shell photoionization cross section. Present experimental results are compared with other experimental and theoretical values. Reasonable agreement (to within 0.3-28%) is typically obtained between present and other experimental and theoretical values.

2005-04-01

128

Accretion Properties of A Sample of Hard X-ray (<60keV) Selected Seyfert 1 Galaxies  

CERN Document Server

We examine the accretion properties in a sample of 42 hard (3-60keV) X-ray selected nearby broad-line AGNs. The energy range in the sample is harder than that usually used in the similar previous studies. These AGNs are mainly complied from the RXTE All Sky Survey (XSS), and complemented by the released INTEGRAL AGN catalog. The black hole masses, bolometric luminosities of AGN, and Eddington ratios are derived from their optical spectra in terms of the broad H$\\beta$ emission line. The tight correlation between the hard X-ray (3-20keV) and bolometric/line luminosity is well identified in our sample. Also identified is a strong inverse Baldwin relationship of the H$\\beta$ emission line. In addition, all these hard X-ray AGNs are biased toward luminous objects with high Eddington ratio (mostly between 0.01 to 0.1) and low column density ($<10^{22} \\mathrm{cm^{-2}}$), which is most likely due to the ...

2008-01-01

130

Radiation exposure of children in pediatric radiology. Pt. 5. Organ doses in chest radiography; Zur Strahlenexposition von Kindern in der paediatrischen Radiologie. T. 5. Organdosen bei der Roentgenuntersuchung des Thorax  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Reconstruction of organ doses of selected organs and tissues from radiographic settings and exposure data collected during chest X-ray examinations of children of various age groups performed in Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007. Materials and Method: The dosimetric data of all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 119 150 chest radiographs of all age groups. Reconstruction of organ doses in 40 organs and tissues in X-ray examinations of the chest was performed based on the conversion factor concept. Results: The radiation exposure of organs in projection radiography is determined by the exact site of the organs relative to the edges of ...

2009-05-15

131

Dual-energy projection radiography using condenser discharge x-ray generator and FCR. Determination of technical factors  

Energy Technology Data Exchange (ETDEWEB)

In dual-energy projection radiography with double exposures, rapid energy switching is mandatory to eliminate motion artifacts, but it is costly for use in a clinical environment. We developed a system with practical exposure intervals at reasonable cost by modifying a condenser-type X-ray generator. A commercially available system for digital radiography (Fuji Computed Radiography, FCR) was used to subtract images. This report dealt with technical factors to obtain adequate kV and mAs settings in this technique.

1987-04-01

132

Dual-energy projection radiography using condenser discharge x-ray generator and FCR  

International Nuclear Information System (INIS)

In dual-energy projection radiography with double exposures, rapid energy switching is mandatory to eliminate motion artifacts, but it is costly for use in a clinical environment. We developed a system with practical exposure intervals at reasonable cost by modifying a condenser-type X-ray generator. A commercially available system for digital radiography (Fuji Computed Radiography, FCR) was used to subtract images. This report dealt with technical factors to obtain adequate kV and mAs settings in this technique. (author).

1987-01-01

133

The Micro-X Imaging Spectrometer Instrument  

Science.gov (United States)

The Micro-X instrument is a NASA funded, rocket borne X-ray imaging spectrometer planned for launch in January 2011. An array of Transition Edge Sensors (TESs) will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. This will be a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat sink, and will be read out by a SQUID time division multiplexer. X-rays will be focused onto the TES array of 128 pixels on a 600 micron pitch by a conically approximated Wolter optic with an effective area of 200 cm2. The spectrometer will have a field of view of 11.8 arcmin. We describe the design and development progress of the ...

2010-01-01

134

Study of chest portable radiography using computed radiography. Removal effect of X-ray scatter by a copper plate  

Energy Technology Data Exchange (ETDEWEB)

When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated through contrast ...

2001-04-01

135

Study of chest portable radiography using computed radiography. Removal effect of X-ray scatter by a copper plate  

International Nuclear Information System (INIS)

When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated through contrast ...

2001-04-01

136

Structural transformations in heat-resistant protective coatings on nickel alloys  

Energy Technology Data Exchange (ETDEWEB)

In this work a comprehensive metallophysical study was carried out for two aluminosilicide slip coatings of the systems Al-Si and Al-Nb-Si and an electron-beam Co-Cr-Al-Y coating on alloy EP-539 (17...19% Cr, 4...6% Co, 2.5...4% W, 4.5...6.5% Mo, 2...3% Ti, 3...4% Al, 1.4...2% Nb, balance Ni) after high-temperature testing. The protective properties of the coatings were evaluated from the results of laboratory tests for heat resistance at 1000/sup 0/C in the combustion products of diesel fuel with added sulfur at 970, 1000, and 1060/sup 0/C for 100 h and after full-scale tests for 150, 250, 400, and 700 h. Metallographic, hardness, x-ray, and micro x-ray studies of the coating were carried out. Layer-by-layer phase composition and the lattice spacing of the main phases were determined. X-ray analysis was carried out in an a DRON-1 diffractometer in copper K/sub ..-->../-radiation, and ...

1987-09-01

138

Molecular conformation, receptor binding, and hormone action of natural and synthetic estrogens and antiestrogens.  

UK PubMed Central (United Kingdom)

The X-ray crystallographic structural determinations of synthetic estrogens and antiestrogens provide reliable information on the global minimum energy conformation of these molecules or a local minimum...Full Text Available

1985-09-01

139

Optimizing radiotherapy of orbital and paraorbital tumors: intensity-modulated X-ray beams vs. intensity-modulated proton beams  

International Nuclear Information System (INIS)

Purpose: This study presents a dosimetric optimization effort aiming to compare intensity-modulated (IM) X-rays and IM protons in 4 different orbital and paraorbital tumors. These are most challenging targets for standard radiotherapy due to their close relationship with the eyes and related structures. Methods and Materials: A primary orbital lymphoma, an optic nerve meningioma, a sphenoidal ridge meningioma protruding into the orbit, and a pediatric parameningeal paraorbital rhabdomyosarcoma were selected for the purpose of this study. Planning target volumes (PTVs) and organs at risk (OAR) were defined in each patient CT data set for each tumor site. IM X-ray and IM proton three-dimensional treatment plans were implemented. The following total tumor doses were prescribed: 30 Gy for the orbital lymphoma, 54 Gy for both meningiomas, and 50.4 Gy for the rhabdomyosarcoma case. Dose-volume histograms (DVHs) were obtained for all targets and OAR ...

2000-07-01

140

IN VACUUM UNDULATOR TASK FORCE REPORT  

Energy Technology Data Exchange (ETDEWEB)

The Green-Chasman lattice, which is the basis for both NSLS storage rings, was conceived with insertion devices in mind. Long, field-free straight sections were provided in the design. The electron optics were chosen so that these sections had zero dispersion and the effects of new magnetic structures placed in these regions would have minimal effect on the emittance of the electron beam. This design concept has been followed by all high-brightness rings which were built subsequent to the NSLS. The X-Ray Ring straight sections also have a very small vertical {beta} function, in addition to the zero dispersion. This was done to optimize the brightness of wiggler sources. There is a further benefit however. The {beta} function determines the beam size and divergence at a particular point in the storage ring lattice. The size is proportional to {radical}{beta} and the divergence is proportional to 1/{radical}{beta}. Thus the ...

1998-06-01

141

Hard x-ray phase imaging using simple propagation of a coherent synchrotron radiation beam  

International Nuclear Information System (INIS)

Particularly high coherence of the x-ray beam is associated, on the ID19 beamline at ESRF, with the small angular size of the source as seen from a point of the sample (0.1-1 #mu#rad). This feature makes the imaging of phase objects extremely simple, by using a 'propagation' technique. The physical principle involved is Fresnel diffraction. Phase imaging is being simultaneously developed as a technique and used as a tool to investigate light natural or artificial materials introducing phase variations across the transmitted x-ray beam. They include polymers, wood, crystals, alloys, composites or ceramics, exhibiting inclusions, holes, cracks, ... . 'Tomographic' three-dimensional reconstruction can be performed with a filtered back-projection algorithm either on the images processed as in attenuation tomography, or on the phase maps retrieved from the images with a reconstruction procedure similar to ...

1999-05-21

142

Luminescence Properties of ScPO{sub 4} Single Crystals  

Energy Technology Data Exchange (ETDEWEB)

Flux-grown ScPO{sub 4} single crystals exhibit a number of luminescence bands in their x-ray-excited luminescence spectra - including sharp lines arising from rare-earth elements plus a number of broad bands at 5.6 cV, 4.4 eV, and 3 eV. The band at 5.6 eV was attributed to a self-trapped exciton (STE) [l], and it could be excited at 7 eV and higher energies. This luminescence is strongly polarized (P = 70 %) along the optical axes of the crystal and exhibits a kinetic decay time constant that varies from several ns at room temperature to {approximately}10 {micro}s at 60 K and up to {approximately}1 ms at 10 K. It is assumed that the STE is localized on the SC ions. The band at 3 eV can be excited in the range of the ScPO{sub 4} crystal transparency (decay time = 3 to 4 {micro}s.) This band is attributed to a lead impurity that creates different luminescence centers. At high temperatures, the band at 4.4 eV is dominant in the ...

1999-08-16

143

Plasma Diagnostics in the Optical and X-ray regions on the Plasma Focus device PF-4 (Installation TYULPAN)  

International Nuclear Information System (INIS)

The results of experiments received on the plasma focus (PF) device with energy stored equal 4 kJ are represented. Photos of the current plasma sheath (CPS), pre-pinch, sphere-like plasma formations are produced with help of the electron-optical converter contained a gated micro-channel plate (MCP) and the CCD-camera imaging system in the visible region. The redial velocity of the CPS is about 107 cm/s. Neon plasma electron density measured with help of the interferograms in the visible region and the spectra in the soft X-ray region is equals to 3?1018 cm-3. Electron temperature is equal to about 200 eV. Discharge integral photos were obtained with help of the soft X-ray pinhole camera. Pictures with 2 ?s resolution of the plasma luminescence above PF anode region were made by CCD-camera.

2006-01-01

144

K-edge X-ray absorption spectra of argon in sputtered aluminum films  

International Nuclear Information System (INIS)

We have measured K-edge X-ray absorption spectra of argon in sputtered aluminum films at a synchrotron radiation facility (the Photon Factory). We found that the energy and shape of white line change when the film is annealed at 500 C and the spectrum becomes resembling that of argon implanted in silicon. From the analyses of the X-ray absorption spectra and TEM observation we concluded that argon exists as very small atom clusters with a diameter less than 1 nm or exist as isolated atoms in the as-sputtered aluminum film, and that the size of the clusters become as big as 10 nm diameter when the film is heated. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

1999-01-04

145

Strain and Texture in Al-Interconnect Wires Measured by X-Ray Microbeam Diffraction  

Energy Technology Data Exchange (ETDEWEB)

The local strain and texture in Al interconnect wires have been investigated using white and monochromatic x-ray microbeams on the MHATTCAT undulator beam line at the Advanced Photon Source. Intergrain and intragrain orientations were obtained with ~0.01 degree sensitivity using white beam measurements on wide Al pads (~100 Mu-m) and thin (2 Mu-m) Al wires. Orientation changes of up to 1 degree were found within individual grains of the (111) textured Al interconnects. Deviatoric strain measurements indicate small intragranular strain variations, but intergranular strain variations were found to be quite large.

1999-04-05

146

ASE FILE  

Science.gov (United States)

radionuclide X-ray fluorescence analysis: the resolving power of the ... The radiation detectors used in radionuclide X-ray fluorescence ...

147

Real-time neutron radiography at the Iea-R1 m nuclear research reactor  

International Nuclear Information System (INIS)

A LIXI (Light Intensifier X-ray Image) device has been employed in a real-time neutron radiography system. The LIXI is coupled to a video camera and the real-time images can be observed in a TV monitor, and processed in a computer. In order to get the real-time system operational, the neutron radiography facility installed at the IEA-R1 m nuclear research reactor of the IPEN-CNEN/S P has been optimized. The most important improvements were the neutron/gamma ratio, the effective energy of the neutron beam, decrease of the scattered radiation at the irradiation position, and the additional shielding of the video camera. Several one-frame as well as computer processed images are presented. The overall Modulation Transfer Function for the real-time system was obtained from the resolution parameter p = 0:44 +- 0:04 mm; the system sensitivity, evaluated for a Perspex step wedge, was determined and the average value is 0:70 +- ...

2003-06-01

148

Large area, low capacitance Si(Li) detectors for high rate x-ray applications  

Energy Technology Data Exchange (ETDEWEB)

Large area, single-element Si(Li) detectors have been fabricated using a novel geometry which yields detectors with reduced capacitance and hence reduced noise at short amplifier pulse-processing times. A typical device employing the new geometry with a thickness of 6 mm and an active area of 175 mm 2 has a capacitance of only 0.5 pf, compared to 2.9 pf for a conventional planar device with equivalent dimensions. These new low capacitance detectors, used in conjunction with low capacitance field effect transistors, will result in x-ray spectrometers capable of operating at very high count rates while still maintaining excellent energy resolution. The spectral response of the low capacitance detectors to a wide range of x-ray energies at 80 K is comparable to typical state-of-the-art conventional Si(Li) devices. In addition to their low capacitance, the new devices offer other advantages over ...

1992-10-01

149

Sunyaev-Zel'dovich Effects from Quasars Shining in Galaxies and Groups  

CERN Document Server

The energy fed by active galactic nuclei to the surrounding diffuse baryons changes the latter's amount, temperature, and distribution; so in groups and in member galaxies it affects the X-ray luminosity and also the Sunyaev-Zel'dovich effect. Here we compute how the latter is enhanced by the transient blastwave driven by a shining quasar, and is depressed when the equilibrium is recovered with a depleted density. We constrain such depressions and enhancements with the masses of relic black holes in galaxies and the X-ray luminosities in groups. We discuss how all these linked observables can tell the quasar contribution to the thermal history of the baryons pervading galaxies and groups.

2003-01-01

150

Photon-induced K-shell X-ray intensity ratio for elements with 74#<=#Z#<=#92  

International Nuclear Information System (INIS)

The K-shell X-ray intensity ratios for W, Au, Tl, Pb, Bi, Th and U were measured at a photon incident energy of 121.9 keV from "5"7Co radionuclide. A comparison between the experimental results and the theoretically calculated values shows that the experimental results are, in general, higher than the theoretical values. The measured intensities are regarded to be reported for the first time. (author) 9 refs.; 1 tab.

1989-01-01

151

Electron temperature diagnostics in the RFX reversed field pinch experiment  

Energy Technology Data Exchange (ETDEWEB)

The paper presents an integrated approach to the problem of electron temperature diagnostics of the plasma in a reversed field pinch. Three different methods, sampling different portions of the electron distribution function, are adopted, namely Thomson scattering, soft X-ray spectroscopy by pulse-height analysis and filtered soft X-ray intensity ratio. A careful analysis of the different sources of systematic errors is performed and a novel statistical approach is adopted to mutually validate the three independent measurements. A satisfactory agreement is obtained over a large range of experimental conditions, indicating that in the plasma core the energy distribution function is well represented by a maxwellian. (author)

2000-08-01

152

X-ray zone plate fabrication using a focused ion beam  

Energy Technology Data Exchange (ETDEWEB)

An x-ray zone plate was fabricated using the novel approach of focused ion beam (FIB) milling. The FIB technique was developed in recent years, it has been successfully used for transmission electron microscopy (TEM) sample preparation, lithographic mask repair, and failure analysis of semiconductor devices. During FIB milling, material is removed by the physical sputtering action of ion bombardment. The sputter yield is high enough to remove a substantial amount of material, therefore FIB can perform a direct patterning with submicron accuracy. The authors succeeded in fabricating an x-ray phase zone plate using the Micrion 9500HT FIB station, which has a 50 kV Ga{sup +} column. Circular Fresnel zones were milled in a 1.0-{micro}m-thick TaSiN film deposited on a silicon wafer. The outermost zone width of the zone plate is 170 nm at a radius of 60 {micro}m. An achieved aspect ratio was 6:1.

2000-08-16

153

Construction of a homogeneous phantom for radiographic image standardization; Construcao de um fantoma homogeneo para padronizacao de imagens radiograficas  

Energy Technology Data Exchange (ETDEWEB)

The principle of radiodiagnosis consists in the fact the X-ray beam is attenuated at different degrees by distinct tissues. For this reason, the anatomical structures have distinct radiological opacities, that produce the radiographic image. The progresses in radiology are related to the development if new radiographic image formation systems that enable an amplification in the quality, with low dose and/or risk to the patient. The objective of this work is the sensitometric valuation of a screen-film combination, that is still the most used, for the standardization, of radiographic images. Thinking about this, were constructed homogeneous phantoms of the chest, skull and pelvis, for the calibration of X-ray beams, with the purpose of obtaining radiographic images of good quality, basing in the routine of a radiodiagnosis service and in the scientific knowledge. Questions were approached about the ...

1996-12-31

154

Application of grazing incidence x-ray diffraction to polymer blends  

Energy Technology Data Exchange (ETDEWEB)

The physical properties of polymer blends consisting of one or more crystallizable components are affected by the microstructure of these materials. In particular, the degree of crystallinity can be influenced by processing parameters, and the crystallinity, as well as the phase distribution, may vary as a function of depth through an injection molded part Conventional x-ray diffraction techniques can provide information regarding both phase composition and degree of crystallinity, but, because of the relative transparency of these materials to wavelengths generally available in the laboratory, these techniques provide information representative of only the bulk. By employing parallel beam optics at varying grazing incidence angles, the x-ray sampling depth can be varied without loss of resolution. This technique can be used to vary the effective analysis depth from the top several hundred angstroms for low razing incidence ...

1992-01-01

155

Application of grazing incidence x-ray diffraction to polymer blends  

Energy Technology Data Exchange (ETDEWEB)

The physical properties of polymer blends consisting of one or more crystallizable components are affected by the microstructure of these materials. In particular, the degree of crystallinity can be influenced by processing parameters, and the crystallinity, as well as the phase distribution, may vary as a function of depth through an injection molded part Conventional x-ray diffraction techniques can provide information regarding both phase composition and degree of crystallinity, but, because of the relative transparency of these materials to wavelengths generally available in the laboratory, these techniques provide information representative of only the bulk. By employing parallel beam optics at varying grazing incidence angles, the x-ray sampling depth can be varied without loss of resolution. This technique can be used to vary the effective analysis depth from the top several hundred angstroms for low razing incidence ...

1992-10-01

156

Predictive model of electron-beam-induced flashblindness. Final report, November 1983-October 1984  

Energy Technology Data Exchange (ETDEWEB)

The spectral characteristics of the Cherenkov radiation have been evaluated and converted to equivalent retinal irradiance from external sources. On the basis of the conversion, electron fluxes have been estimated for 2-sec recovery times from flashblindness. The electrons are assumed to have energies greater than 6 MeV and to be delivered in one or more bursts of 1 microsecond each over 1 sec. It is important to note that very little data exists on recovery times as short as 2 sec for either photopic and scotopic conditions. This situation is a direct result of the lack of definition of the critical tasks and their sensitivity to an interruption of background adaptation. The Cherenkov radiation produced within the eye by relativistic electrons can be compared to light from external sources by the relationships: 1 rad approx. = 4.6 scotopic td-sec and 1 rad approx. = 0.55 photopic td sec. Based on these conversion factors, the following estimates can be derived by ...

1985-03-01

157

Mapping Strain in Nanocrystalline Nitinol: an X-ray Diffraction Method (SULI paper)  

Energy Technology Data Exchange (ETDEWEB)

Understanding the mechanical properties of biomedical devices is critical in predicting and preventing their failure in the body. Such knowledge is essential, for example, in the design of biomedical stents, which must undergo repeated strain over their ten year lifetimes without breaking. Computational models are used to predict mechanical response of a device, but these models are not complete; there are significant deviations from the predictions, especially when devices are subjected to repeated multi-axial loads. Improving these models requires comparisons with actual measurements of strained nitinol. Local measurements of the full strain tensor can be made using X-ray diffraction techniques, but they are currently limited to materials whose grain size is larger than the X-ray beam size or require several diffraction patterns produced by rotation of the sample. Nitinol stents are nanocrystalline, with grains smaller ...

2006-01-04

158

Valence electronic structure of Ni in Ni-Si alloys from relative K X-ray intensity studies  

Energy Technology Data Exchange (ETDEWEB)

The K{beta}-to-K{alpha} X-ray intensity ratio of Ni in Ni{sub 3}Si, Ni{sub 2}Si and NiSi has been determined by energy dispersive X-ray fluorescence technique. It is found that the intensity ratio of Ni decreases from pure Ni to Ni{sub 2}Si and then increases from Ni{sub 2}Si to NiSi, in good agreement with the electronic structure calculations cited in the literature. We have also performed band structure calculations for pure Ni in various atomic configurations by means of linear muffin-tin orbital method and used this data with the normalized theoretical intensity ratios cited in the literature to estimate the 3d-occupation numbers of Ni in Ni-Si alloys. It is emphasized that investigation of alloying effect in terms of X-ray intensity ratios should be carried out for the stoichiometric alloys in order to make reliable and quantitative comparisons between theory and experiment in transition metal ...

2007-02-15

159

Swift panchromatic observations of the bright gamma-ray burst GRB050525a  

CERN Document Server

The bright gamma-ray burst GRB050525a has been detected with the Swift observatory, providing unique multiwavelength coverage from the very earliest phases of the burst. The X-ray and optical/UV afterglow decay light curves both exhibit a steeper slope ~0.15 days after the burst, indicative of a jet break. The timing of the jet break combined with the total gamma-ray energy of the burst constrains the opening angle of the jet to be 2.5 degrees. We derive an empirical `time-lag' redshift from the BAT data of z_hat = 0.69 +/- 0.02, in good agreement with the spectroscopic redshift of 0.61. Prior to the jet break, the X-ray data can be modelled by a simple power law with index alpha = -1.2. However after 300s the X-ray flux brightens by about 30% compared to the power-law fit. The optical/UV data have a more complex decay, with evidence of a rapidly falling reverse shock component that dominates in the ...

2006-01-01

160

Phase, residual stress, and texture in triode-sputtered tantalum coatings on steel. Final report  

Energy Technology Data Exchange (ETDEWEB)

This work analyzes the unoptimized prototype triode-sputtered, 150 microns thick tantalum coatings deposited with a 2.5 microns niobium underlayer on the bore of a large-diameter A723 steel cylinder. The coating was deposited for wear and erosion protection by Pacific Northwest National Laboratory. The phase determination was based on X ray diffraction analysis, wavelength dispersive X ray fluorescence analysis, energy dispersive X ray analysis, and hardness and electrical resistivity measurements. Both X ray diffraction and radius-of- curvature methods were used to determine residual stresses. A locally developed high-resolution pole figure technique was used to perform texture analysis. The post-firing, debonded coating showed alpha-tantalum, preferred 110 orientation, high surface stresses, ...

1998-07-01

161

Determination of trace elements in Syrian medicinal plants and their infusions by energy dispersive X-ray fluorescence and total reflection X-ray fluorescence spectrometry  

Energy Technology Data Exchange (ETDEWEB)

X-ray fluorescence (XRF) and total-reflection X-ray fluorescence (TXRF) techniques suited well for a multi-element determination of K, Ca, Mn, Fe, Cu, Zn, Rb, and Sr in some Syrian medicinal plant species. The accuracy and the precision of both techniques were verified by analyzing the Standard Reference Materials (SRM) peach-1547 and apple leaves-1515. A good agreement between the measured concentrations of the previously mentioned elements and the certified values were obtained with errors less than 10.7% for TXRF and 15.8% for XRF. The determination of Br was acceptable only by XRF with an error less than 24%. Furthermore, the XRF method showed a very good applicability for the determination of K, Ca, Mn, Fe, Cu, Zn, Rb, Sr, and Br in infusions of different Syrian medicinal plant species, namely anise (Anisum vulgare), licorice root (Glycyrrhiza glabra), and white wormwood (Artemisia herba-alba)

2009-07-15

162

X-ray ablation measurements and modeling for ICF applications  

Energy Technology Data Exchange (ETDEWEB)

X-ray ablation of material from the first wall and other components of an ICF (Inertial Confinement Fusion) chamber is a major threat to the laser final optics. Material condensing on these optics after a shot may cause damage with subsequent laser shots. To ensure the successful operation of the ICF facility, removal rates must be predicted accurately. The goal for this dissertation is to develop an experimentally validated x-ray response model, with particular application to the National Ignition Facility (NIF). Accurate knowledge of the x-ray and debris emissions from ICF targets is a critical first step in the process of predicting the performance of the target chamber system. A number of 1-D numerical simulations of NIF targets have been run to characterize target output in terms of energy, angular distribution, spectrum, and pulse shape. Scaling of output characteristics with variations of both ...

1996-09-01

163

Depth profile of uncompensated spins in an exchange bias system  

Energy Technology Data Exchange (ETDEWEB)

We have used the unique spatial sensitivity of polarized neutron and soft x-ray beams in reflection geometry to measure the depth dependence of magnetization across the interface between a ferromagnet and antiferromagnet. The new uncompensated magnetization near the interface responds to applied field, while the uncompensated spins in the antiferromagnetic bulk are pinned, thus providing a means to establish exchange bias.

2005-05-17

164

Carbon beam irradiation of human monolayer cells  

Energy Technology Data Exchange (ETDEWEB)

The effect of the heavy particle irradiation on cell survival is different from that of X-ray irradiation. In Japan, heavy particles will be applied to cancer patients in the near future. This study was performed to determine the effect that carbon particle irradiation exerts to human monolayer cells in vitro, in comparison with the effect of 200 kVp X-ray. Two human cell lines, HeLaS3 and RMUG, were used. The irradiation was carried out by the RIKEN ring cyclotron and 200 kVp X-ray. The experimental procedure is explained. Also split dose experiment was carried out by applying equally divided doses at intervals of 2 - 4 hours. The Bragg curve of 135 MeV/n carbon beam through the lucite plates with different thickness is given. Thus the different LETs were obtained. The survival curves for 200 kVp X-ray and the various LETs of carbon beam are shown. The curves ...

1993-12-31

165

In vitro H2AX phosphorylation and micronuclei induction in human fibroblasts across the Bragg curve of a 577MeV/nucleon Fe incident beam  

Energy Technology Data Exchange (ETDEWEB)

The space environment consists of a varying field of radiation particles including high-energy ions, with spacecraft shielding material providing the only major protection to astronauts from harmful exposure. Unlike low-linear energy transfer (LET) {gamma} or X-rays, the presence of shielding does not always reduce the radiation risks for energetic charged particle exposure, since the dose delivered by the charged particle increases sharply as the particle approaches the end of its range, a position known as the Bragg peak. The Bragg curve does not necessarily represent the biological damage along the particle traversal, and the 'biological Bragg curve' is dependent on the energy and the type of the primary particle, and may vary for different biological endpoints. Here we used a unique irradiation geometry to measure the biological response across the Bragg curve in human fibroblasts ...

2006-10-15

166

Transverse Coherence Properties of the LCLS X-Ray Beam  

Science.gov (United States)

Self-amplifying spontaneous radiation free-electron lasers, such as the LCLS or the European X-FEL, rely on the incoherent, spontaneous radiation as the seed for the amplifying process. Though this method overcomes the need for an external seed source one drawback is the incoherence of the effective seed signal. The FEL process allows for a natural growth of the coherence because the radiation phase information is spread out within the bunch due to slippage and diffraction of the radiation field. However, at short wavelengths this spreading is not sufficient to achieve complete coherence. In this presentation we report on the results of numerical simulations of the LCLS X-ray FEL. From the obtained radiation field distribution the coherence properties are extracted to help to characterize the FEL as a light source.

2007-04-16

167

Real-time orbit feedback at the APS.  

Energy Technology Data Exchange (ETDEWEB)

A real-time orbit feedback system has been implemented at the Advanced Photon Source in order to meet the stringent orbit stability requirements. The system reduces global orbit motion below 30Hz by a factor of four to below 5{micro}m rms horizontally and 2{micro}m rms vertically. This paper focuses on dynamic orbit stability and describes the all-digital orbit feedback system that has been implemented at the APS. Implementation of the global orbit feedback system is described and its latest performance is presented. Ultimately, the system will provide local feedback at each x-ray source point using installed photon BPMs to measure x-ray beam position and angle directly. Technical challenges associated with local feedback and with dynamics of the associated corrector magnets are described. The unique diagnostic capabilities provided by the APS system are discussed with reference to their use in identifying sources of the ...

1998-06-18

168

A study of reconstruction algorithms and filters for an industrial X-ray tomography system  

Energy Technology Data Exchange (ETDEWEB)

Computed tomography (CT) has been incorporated in an industrial Diode-Array Digital Radiography (DADR) system. An input data size of 512 pixel points x 400 projections yielded a 400x400 output image matrix. Reconstruction algorithms used are the filtered backprojection (FBP) and the direct Fourier reconstruction (DFR). Various filters were used in the FBP reconstruction process and their effects on image quality were evaluated. A spatial resolution of 100 {mu}m was measured with a block of plates and a minimum detectable feature size in the range of 10-100 {mu}m was measured using thin wires. Industrial specimens imaged have included ceramic samples, ball bearings and integrated circuits. A number of engineering problems have been solved, such as adjustment of the X-ray source, centering of the rotator spindle in the view field and beam-hardening corrections. (orig.).

1990-12-20

169

A pump-probe XFEL particle injector for hydrated samples  

CERN Document Server

We have developed a liquid jet injector system that can be used for hydrated sample delivery at X-ray Free Electron Laser (XFEL) sources and 3rd generation synchrotron sources. The injector is based on the Gas Dynamic Virtual Nozzle (GDVN), which generates a liquid jet with diameter ranging from 300 nm to 20 {\\mu}m without the clogging problems associated with conventional Rayleigh jets. An improved nozzle design is presented here. A differential pumping system protects the vacuum chamber and an in-vacuum microscope allows observation of the liquid jet for diagnostics while it is being exposed to the X-ray beam. A fiber optically coupled pump laser illuminating the jet is incorporated for pump-probe experiments. First results with this injector system have been obtained at the LCLS.

2011-01-01

170

Processing of La/sub 1. 8/Sr/sub 0. 2/CuO/sub 4/ and YBa/sub 2/Cu/sub 3/O/sub 7/ superconducting thin films by dual-ion-beam sputtering  

Science.gov (United States)

High quality La/sub 1.8/Sr/sub 0.2/CuO/sub 4/ and YBa/sub 2/Cu/sub 3/O/sub 7/ superconducting thin films, with zero resistance at 88 K, have been made by dual-ion-beam sputtering of metal and oxide targets at elevated temperatures. The films are about 1.0 ..mu..m thick and are single phase after annealing. The substrates investigated are Nd-YAP, MgO, SrF/sub 2/, Si, CaF/sub 2/, ZrO/sub 2/-9% Y/sub 2/O/sub 3/, BaF/sub 2/, Al/sub 2/O/sub 3/, and SrTiO/sub 3/. Characterization of the films was carried out using Rutherford backscattering spectroscopy, resistivity measurements, transmission electron microscopy, x-ray diffraction, and secondary ion mass spectroscopy. Substrate/film interaction was observed in every case. This generally involves diffusion of the substrate into the film, which is accompanied by, for example, the replacement of Ba by Sr in the YBa/sub 2/Cu/sub 2/O/sub 7/ structure, in the case of SrTiO/sub 3/ substrate. The best ...

1988-03-15

171

Focused Ion Beam Recovery of Hypervelocity Impact Residue in Experimental Craters on Metallic Foils.  

Energy Technology Data Exchange (ETDEWEB)

The Stardust sample return capsule will return to Earth in January 2006 with primitive debris collected from Comet 81P/Wild-2 during the fly-by encounter in 2004. In addition to the cometary particles embedded in low-density silica aerogel, there will be microcraters preserved in the Al foils (1100 series; 100 {micro}m thick) that are wrapped around the sample tray assembly. Soda lime spheres ({approx}49 {micro}m in diameter) have been accelerated with a Light Gas Gun into flight-grade Al foils at 6.35 km s{sup -1} to simulate the capture of cometary debris. The experimental craters have been analyzed using scanning electron microscopy (SEM) and x-ray energy dispersive spectroscopy (EDX) to locate and characterize remnants of the projectile material remaining within the craters. In addition, ion beam induced secondary electron imaging has proven particularly useful in identifying areas within the craters that contain ...

2005-11-04

172

Investigation by XRF and XRD of Zn and Fe in Fe{sub x} Zn{sub 1-x} thin films  

Energy Technology Data Exchange (ETDEWEB)

Fe{sub x}Zn{sub 1-x} alloys were electrochemically deposited on aluminum substrates from a sulfate bath. The K{beta}/K{alpha} x-ray intensity ratios of Zn and Fe in Fe{sub x}Zn{sub 1-x} thin films have been experimentally studied. The energy dispersive x-ray fluorescence (EDXRF) technique was used to measure K x-ray photons. Samples were excited by using 59.5 keV photons emitted by a 50 mCi {sup 241}Am radioactive source. The emitted K x-rays were detected by an Ultra-LEGe detector having a resolution of 150 eV at 5.9 keV. In addition, the effect of bath composition on the phase structure was investigated by x-ray diffraction (XRD) analysis. The composition of the thin films was analyzed by atomic absorption spectrometry analysis. Iron content was shown to strongly affect the structure of Zn-Fe alloys. It was found that the K-shell x-ray ...

2008-12-15

173

Investigation by XRF and XRD of Zn and Fe in Fex Zn1-x thin films  

International Nuclear Information System (INIS)

FexZn1-x alloys were electrochemically deposited on aluminum substrates from a sulfate bath. The K?/K? x-ray intensity ratios of Zn and Fe in FexZn1-x thin films have been experimentally studied. The energy dispersive x-ray fluorescence (EDXRF) technique was used to measure K x-ray photons. Samples were excited by using 59.5 keV photons emitted by a 50 mCi 241Am radioactive source. The emitted K x-rays were detected by an Ultra-LEGe detector having a resolution of 150 eV at 5.9 keV. In addition, the effect of bath composition on the phase structure was investigated by x-ray diffraction (XRD) analysis. The composition of the thin films was analyzed by atomic absorption spectrometry analysis. Iron content was shown to strongly affect the structure of Zn-Fe alloys. It was found that the K-shell x-ray intensity ratio changed in FexZn1-x thin ...

2008-12-01

174

X-Ray Fluorescence Analysis of Composite Propellants for ...  

Science.gov (United States)

... The constancy of the X-ray intensity ratio for each element in Table 8 as the X-ray tube settings were changed shows the excellent compensating ...

1977-06-03

175

Radionuclide X-ray fluorescence analysis. 1: Excitation of X-ray fluorescense radiation by nuclear radiation  

Science.gov (United States)

The principles of radionuclide excitation of X-ray fluorescence radiation and its application in

1972-01-01

176

Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation  

Science.gov (United States)

This investigation describes the technique for the detection of the X-ray fluorescent radiation

1972-01-01

177

Radiographic in-situ measurements of intrinsic stresses between 750 C and 900 C. Optimisation of the measuring system; Roentgenographische In-situ-Messungen der Eigenspannungen zwischen 750 C und 900 C. Optimierung der Messeinrichtung  

Energy Technology Data Exchange (ETDEWEB)

One aspect of the research program SFB 570 'Distortion engineering' is the in situ X-Ray diffraction analysis of phases and residual stresses during complete heat treatment cycles. These investigations result in experimental evidence available for the extensive computations. The optimisation of the instrumentation will be reported. A surface decarburisation of samples made from the ball bearing steel 100Cr6 could be avoided for a temperature range from 800 to 900 C and a holding time of one hour by a combination of evacuate the furnace and using a certain nitrogen flow as protective gas. At lower temperatures small amounts of ferrite caused by an increased diffusion rate of carbon lead again to a surface decarburisation up to a depth of 2 {mu}m. It was proved that with an evacuation of the X-Ray beam path at constant power of the X-Ray source the intensity of diffraction lines could be ...

2007-07-01

178

Comparison of two dose-area-product ionization chambers with different conductive surface coating for over-table and under-table tube configurations  

Energy Technology Data Exchange (ETDEWEB)

A custom-built graphite-coated transmission ionization chamber is compared to the VacuDAP 2001 (VacuTec, Dresden, Germany), which has transparent conductive electrodes. A study was made of the dependence of response on x-ray tube potential for both types of chamber under identical conditions of exposure using over-table and under-table x-ray tubes. Since the calibration factor is the dose-area product of the radiation incident on the patient per chamber reading, it depends on the intrinsic response of the chamber as well as the effect of material in the beam between the x-ray tube and patient. Differences of about 20% were measured between the intrinsic and the over-table calibration factors and between the over-table and the under-table calibration factors for both chambers. The VacuDAP display is specifically calibrated for the over-table condition and would overstate the actual DAP in the under-table ...

2000-03-01

179

Ion beam analysis of high temperature superconducting samples  

Energy Technology Data Exchange (ETDEWEB)

Characterization of high temperature superconducting film and bulk samples has been carried out using 2 MeV [alpha]-particle Rutherford backscattering, 2.4 MeV proton elastic scattering, 2.4 MeV proton-induced x-ray emission, 9 MeV proton induced [gamma]-ray emission and 100 MeV iodine elastic recoil detection analysis techniques. The objective was to compare different ion beam based techniques for: (i) compositional analysis; and (ii) consistency of the results obtained for samples prepared using similar preparation methodology. (author).

1994-02-01

180

A New Measurement of Kaonic Hydrogen X rays  

CERN Document Server

The $\\bar{K}N$ system at threshold is a sensitive testing ground for low energy QCD, especially for the explicit chiral symmetry breaking. Therefore, we have measured the $K$-series x rays of kaonic hydrogen atoms at the DA$\\Phi$NE electron-positron collider of Laboratori Nazionali di Frascati, and have determined the most precise values of the strong-interaction energy-level shift and width of the $1s$ atomic state. As x-ray detectors, we used large-area silicon drift detectors having excellent energy and timing resolution, which were developed especially for the SIDDHARTA experiment. The shift and width were determined to be $\\epsilon_{1s} = -283 \\pm 36 \\pm 6 {(syst)}$ eV and $\\Gamma_{1s} = 541 \\pm 89 {(stat)} \\pm 22 {(syst)}$ eV, respectively. The new values will provide vital constraints on the theoretical description of the ...

2011-01-01

181

Energy dependence of Ksub(#beta#)/Ksub(#alpha#) intensity ratio of Si0_2 from proton induced ionisation  

International Nuclear Information System (INIS)

The Ksub(#beta#)/Ksub(#alpha# 12) x-ray intensity ratio of the Si K spectrum was measured for proton impact on Si0_2 in the energy range 300-800 keV. An energy dependence of the intensity ratio was found and an explanation is given in terms of multiple ionisation. (author).

1980-04-01

182

Water structure as a function of temperature from X-ray scatteringexperiments and ab initio molecular dynamics  

Energy Technology Data Exchange (ETDEWEB)

We present high-quality X-ray scattering experiments on pure water taken over a temperature range of 2 to 77 C using a synchrotron beam line at the advanced light source (ALS) at Lawrence Berkeley National Laboratory. The ALS X-ray scattering intensities are qualitatively different in trend of maximum intensity over this temperature range compared to older X-ray experiments. While the common procedure is to report both the intensity curve and radial distribution function(s), the proper extraction of the real-space pair correlation functions from the experimental scattering is very difficult due to uncertainty introduced in the experimental corrections, the proper weighting of OO, OH, and HH contributions, and numerical problems of Fourier transforming truncated data in Q-space. Instead, we consider the direct calculation of X-ray scattering spectra using electron densities derived ...

2003-03-01

183

Advantages of magnification in digital phase-contrast mammography using a practical X-ray tube  

Energy Technology Data Exchange (ETDEWEB)

Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point source results in a phase contrast too narrow for detection with CR. In addition to phase ...

2008-12-15

184

Analysis of degradation in nickel-based alloys using focused ion beam imaging and specimen preparation combined with analytical electron microscopy  

International Nuclear Information System (INIS)

Focused ion beam (FIB) microscopes have become well-established in the semiconductor industry during the past decade, and are rapidly gaining attention in the field of materials science, both as a tool for producing site specific, parallel sided transmission electron microscope (TEM) specimens and as stand alone specimen preparation and imaging systems. FIB secondary electron imaging (SEI) of nickel-based alloys, such as commercially produced Alloy 600 (approximately Ni 15Cr 10Fe 0.5C), has been demonstrated to show a high degree of sensitivity to the presence of deformation in the alloy, and FIB secondary ion imaging (SII) is particularly useful for identifying the presence of grain boundary corrosion, as secondary ion yields from metallic specimens can increase by three orders of magnitude in the presence of oxygen. This 'oxygen enhanced yield', makes FIB SII ideal for detection of corrosion at grain boundaries down to thicknesses of only a few tens of ...

2002-09-23

185

How epitaxial are Pd/sub 2/Si-Si interfaces  

Energy Technology Data Exchange (ETDEWEB)

Pd/sub 2/Si layers produced by evaporation or sputtering onto silicon substrates were examined by high resolution electron microscopy, microdiffraction, X-ray, energy loss and Auger spectroscopy. The Si-Pd/sub 2/Si interfaces produced by evaporation were in all cases rougher and more polycrystalline than those produced by sputtering. X-ray microanalysis showed the predictable variation in palladium distribution across the interface but quantification did not produce the expected palladium-to-silicon ratios, primarily because of probe broadening and X-ray-induced fluorescence. Energy loss spectra showed plasmon energy shifts and changes in Si L edge shape due to bond formation with palladium. Auger data provided evidence for a small amount of oxygen at the Si-Pd/sub 2/Si interface. Electrical measurements of the ideality factor for Schottky barriers made from the ...

1983-06-17

186

Direct observation of radial distribution change during tensile deformation of metallic glass by high energy X-ray diffraction method  

International Nuclear Information System (INIS)

The purpose of this research is to investigate the micro-mechanism of deformation behavior of metallic glasses. We report the results of direct observations of short-range and medium-range structural change during tensile deformation of metallic glasses by high energy X-ray diffraction method. Cu50Zr50 and Ni30Zr70 metallic glass samples in the ribbon shape (1.5 mm width and 25 ?m) were made by using rapid quenching method. Tensile deformation added to the sample was made by using special equipment adopted for measuring the high energy X-ray diffraction. The peaks in pair distribution function g(r) for Cu50Zr50 and N30iZr70 metallic glasses move zigzag into front and into rear during tensile deformation. These results of direct observation on atomic distribution change for Cu50Zr50 and Ni30Zr70 metallic glass ribbons during tensile deformation suggest that the micro-relaxations occur.

2009-08-26

191

Micro-strip metal foil detectors for the beam profile monitoring  

Energy Technology Data Exchange (ETDEWEB)

The Micro-strip Metal Foil Detectors (MMFD) designed and used for the Beam Profile Monitoring (BPM) are discussed. The results obtained for the MMFDs produced by different technologies are presented. The MMFD deposited onto the 20 {mu}m thick Si-wafer has been used for the BPM of the 32 MeV alpha-particle beam at the MPIfK (Heidelberg) Tandem generator. Another MMFD with totally removed Si-wafer at the working area has been applied for the on-line X-ray BPM at the HASYLAB (DESY). One may conclude that the developed technology of the micro-strip metal detector manufacturing allows to provide non-destructive measurement of X-ray intensity distribution over area of up to 50 mm{sup 2} with an accuracy of 10-20 {mu}m with a possibility of its improvement by a factor 5. A sub-micron position resolution is expected by applying electron lithography for the strip pattern production.

2005-07-01

192

Review of High Gain FELs  

Science.gov (United States)

For understanding on basic radiation mechanism of the high-gain FEL based on SASE, the author presents electron-crystal interpretation of FEL radiation. In the electron-crystal, electrons are localized at regularly spaced multi-layers, which represents micro-bunching, whose spacing is equal to the radiation wavelength, and the multi-layers are perpendicular to beam axis, thus, diffracted wave creates Bragg's spots in forward and backward directions. Due to the Doppler's effect, frequency of the back-scattered wave is up-converted, generates forwardly focused X-ray. The Bragg's effect contributes focusing the X-ray beam into a spot, thus peak power becomes extremely higher by factor of typically 107. This is the FEL radiation. As well known, the total numbers of scattered photons in Bragg's spots is equal to the total elastic scattering photons from the atoms contained ...

2007-01-19

193

The X-ray Ordinance  

International Nuclear Information System (INIS)

The sections and provisions of the X-ray Ordinance of January 8, 1987 are discussed which are of relevance to dental radiology. (DG).

194

Use of primary electron counting for detection of ultrasoft x-rays with a low-pressure multistep gaseous detector  

International Nuclear Information System (INIS)

The use of primary electron counting techniques as an alternative to the more usual parallel plate avalanche chamber that has been employed in soft x-ray scattering experiments is being investigated at the National Synchrotron Light Source. The theoretical aspects of primary electron counting and motivation behind building a primary electron counting detector are described, as well as characteristics and future improvements of the device constructed at the NSLS. The detector consists of a low electric field drift region and a low pressure multistep avalanche region which can be operated with two or three stages of electron multiplication. The device has worked well in extensive tests as a simple parallel plate avalanche chamber, providing energy resolutions of 58% and 43% at 277 and 500 eV, respectively. Operated as a primary electron counter, preliminary results show an energy resolution of 38% at 500 eV.

195

Non-destructive Imaging of Individual Bio-Molecules  

CERN Document Server

Radiation damage is considered to be the major problem that still prevents imaging an individual biological molecule for structural analysis. So far, all known mapping techniques using sufficient short wave-length radiation, be it X-rays or high energy electrons, circumvent this problem by averaging over many molecules. Averaging, however, leaves conformational details uncovered. Even the anticipated use of ultra-short but extremely bright X-ray bursts of a Free Electron Laser shall afford averaging over 10^6 molecules to arrive at atomic resolution. Here we present direct experimental evidence for non-destructive imaging of individual DNA molecules. In fact, we show that DNA withstands coherent low energy electron radiation with deBroglie wavelength in the Angstrom regime despite a vast dose of 10^8 electrons/nm^2 accumulated over more than one hour.

2009-01-01

196

Application of CaSO4:Dy (TLD-900) to diagnostic x-ray exposures  

International Nuclear Information System (INIS)

The properties of a new commercial thermoluminescent dosimeter, CaSO4:Dy without a LiF binder (TLD-900) was studied for low-exposure measurements in diagnostic radiology. The former TLD-900 had a LiF binder (herein referred to as ''TLD-900/LiF''). The principle features of this dosimeter are its high sensitivity to low-energy radiation and its relatively low fading which permits measurements down to less than 2.6 X 10(-8) C kg (0.1 mR) with an accuracy better than 20%. The characteristics, annealing procedures, light sensitivity, energy response, reproducibility, and fading, of TLD-900 are discussed and compared with TLD-900/LiF. When the precautions presented in this paper are used, the dosimeters can be used for the measurement of x-ray exposures.

197

Benzene molecule is destroyed by ultraviolet and soft X-rays in circumstellar environment  

International Nuclear Information System (INIS)

Benzene molecules , present in the proto-planetary nebula CRL 618, are ionized and dissociated by ultraviolet (UV) and X-ray photons originated from the hot central star and by its fast wind. Ionic species and free radicals produced by these processes can lead to the formation of new organic molecules. The aim of this work is to study the photoionization and photodissociation processes of the benzene molecule, using synchrotron radiation and time-of-flight mass spectrometry. Mass spectra were recorded at different energies corresponding to the vacuum UV (21.21 eV) and soft X-ray (282-310 eV) spectral regions. The production of ions from the benzene dissociative photoionization is here quantified, indicating that C_6H_6 is more efficiently fragmented by soft X-ray than UV radiation, where 50% of the ionized benzene molecules survive to UV dissociation while only about 4% resist to C-rays. Partial ion ...

198

Theoretical transition energies, lifetimes and fluorescence yields of multiply ionized silicon  

Energy Technology Data Exchange (ETDEWEB)

Theoretical x-ray transition energies, lifetimes and partial multiplet fluorescence yields are presented for all spectroscopic terms of electron configurations with a single K-shell vacancy and varying number of electrons in the L-shell and M/sub 1/-subshell for multiply-ionized silicon. 9 tables.

1982-01-01

199

Real-time neutron radiography; Radiografia com neutrons em tempo-real  

Energy Technology Data Exchange (ETDEWEB)

The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the {gamma}-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10{sup 6}n/cm{sup 2}s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/{gamma} ratio {approx} 10{sup 6}n/cm{sup 2}mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame ...

2000-07-01

200

Real-time neutron radiography  

International Nuclear Information System (INIS)

The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the #gamma#-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10"6n/cm"2s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/#gamma# ratio #approx# 10"6n/cm"2mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame grabber and a ...

2000-01-01

201

Development of a pump-probe facility combining a far-infrared source with laser-like characteristics and a VUV free electron laser  

International Nuclear Information System (INIS)

The TESLA Test Facility (TTF) at DESY is a facility producing sub-picosecond electron pulses for the generation of VUV or soft X-ray radiation in a free electron laser (FEL). The same electron pulses would also allow the direct production of high-power coherent radiation by passing the electron beam through an undulator. Intense, coherent far-infrared (FIR) undulator radiation can be produced from electron bunches at wavelengths longer than or equal to the bunch length. The source described in this paper provides, in the wavelength range 50-300 #mu#m, a train of about 1-10 ps long radiation pulses, with about 1 mJ of optical energy per pulse radiated into the central cone. The average output power can exceed 50 W. In this conceptual design, we intend to use a conventional electromagnetic undulator with a 60 cm period length and a maximum field of 1.5 T. The FIR source will use the spent electron beam ...

2001-12-21

202

Microstructures for high-energy x-ray and particle-imaging applications  

Energy Technology Data Exchange (ETDEWEB)

Coded imaging techniques using thick, micro-Fresnel zone plates as coded apertures have been used to image x-ray emissions (2-20 keV) and 3.5 MeV Alpha particle emissions from laser driven micro-implosions. Image resolution in these experiments was 3-8 ..mu..m. Extension of this coded imaging capability to higher energy x-rays (approx. 100 keV) and more penetrating charged particles (e.g. approx. 15 MeV protons) requires the fabrication of very thick (50-200 ..mu..m), high aspect ratio (10:1), gold Fresnel zone plates with narrow linewidths (5-25 ..mu..m) for use as coded aperatures. A reactive ion etch technique in oxygen has been used to produce thick zone plate patterns in polymer films. The polymer patterns serve as electroplating molds for the subsequent fabrication of the free-standing gold zone plate structures.

1981-05-01

203

Microstructures for high-energy x-ray and particle imaging applications  

Energy Technology Data Exchange (ETDEWEB)

Coded imaging techniques using thick, micro-Fresnel zone plates as coded apertures have been used to image x-ray emission (2--20 keV) and 3.5 MeV Alpha particle emissions from laser driven micro-implosions. Image resolution in these experiments was 3--8 ..mu..m. Extension of this coded imaging capability to higher energy x rays (approx.100 KeV) and more penetrating charged particles (e.g., approx.15 MeV protons) requires the fabrication of very thick (50--200 ..mu..m), high aspect ratio (10:1), gold Fresnel zone plates with narrow linewidths (5--25 ..mu..m) for use as coded apertures. A reactive ion etch technique in oxygen has been used to produce thick zone plate patterns in polymer films. The polymer patterns serve as electroplating molds for the subsequent fabrication of the free-standing gold zone plate structures.

1981-11-01

204

Integration and Testing of the Micro-X Rocket Payload  

Science.gov (United States)

The Micro-X instrument is a rocket borne, X-ray imaging spectrometer planned for launch in October 2011. An array of 128 Transition Edge Sensors (TESs) on a 600 micron pitch will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. X-rays will be focused onto the TES array by a conically approximated Wolter optic with an effective area of 300 cm^2 giving the instrument a field of view of 11.8 arcmin. This performance will constitute a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat bath, and will be read out by a SQUID time division multiplexer. The first flight of the Micro-X instrument will observe the ...

2011-05-01

205

A MODEL OF THE SPECTRAL EVOLUTION OF PULSAR WIND NEBULAE  

International Nuclear Information System (INIS)

We study the spectral evolution of pulsar wind nebulae (PWNe) taking into account the energy injected when they are young. We model the evolution of the magnetic field inside a uniformly expanding PWN. Considering time-dependent injection from the pulsar and coolings by radiative and adiabatic losses, we solve the evolution of the particle distribution function. The model is calibrated by fitting the calculated spectrum to the observations of the Crab Nebula at an age of a thousand years. The spectral evolution of the Crab Nebula in our model shows that the flux ratio of TeV #gamma#-rays to X-rays increases with time, which implies that old PWNe are faint in X-rays, but not in TeV #gamma#-rays. The increase of this ratio is because the magnetic field decreases with time and is not because the X-ray emitting particles are cooled more rapidly than the TeV #gamma#-ray emitting particles. Our spectral ...

2010-06-01

206

Time-Dependent Propagation of High-Energy Laser Beams ...  

Science.gov (United States)

... Law Parameter 28 Summary 28 6. CIRCULAR VS ANNULAR LASER BEAMS 29 7. HIGH-ENERGY LASER BEAM PROPAGATION THROUGH A ...

1977-12-14

207

X-ray micro-spectroscopy: a tool for micro-scale radionuclide speciation in heterogeneous nuclear waste repository materials  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: Large-scale problems such as nuclear waste disposal are increasingly recognized to be interconnected to small scale-mechanisms. Thus, synchrotron-based high-resolution analytical X-ray probes become important tools for exploring the micro-scale chemical reactivity of heterogeneous barrier materials used in nuclear waste repositories. In this study the layout of the micro-XAS beamline at the Swiss Light Source (SLS) will be presented. The beamline is optimized towards micro beam experiments ({approx}1 x 1 {mu}m{sup 2}) in the hard-X-ray regime (4 - {approx}22 keV) and allows to combine micro X-ray fluorescence (micro-XRF), micro X-ray absorption spectroscopy (micro- XAS), and micro X-ray diffraction (micro-XRD) investigations with radioactive samples. Furthermore, the potential of micro-XRF/XAS/XRD for acquiring spatially ...

2005-07-01

208

X-ray photoelectron spectroscopy and x-ray excited Auger spectroscopy studies of manganese thiophosphate intercalated with sodium ions  

Science.gov (United States)

Polycrystalline powders of Na{sub 2x}Mn{sub 1-x}PS{sub 3} have been synthesized from layered MnPS{sub 3} material by successive ion-exchange intercalation of potassium and sodium ions. Their x-ray photoelectron spectroscopy (XPS) and x-ray excited Auger spectroscopy spectra have been measured at room temperature using Mg K{alpha} (1253.6 eV) x-ray source. In particular, the Mn, P, and S 2p and Na 1s and 2p core-level regions and the Na Auger KL{sub 23}L{sub 23} transition have been investigated. All the analyzed XPS core-level spectra display a single-peak structure, suggesting the absence of nonequivalent atoms of Na, Mn, P, and S. The manganese XPS spectrum shows, as observed in MnPS{sub 3} and in its cesium and potassium intercalation compounds, typical shake-up satellites, suggesting that the Mn-S bond is yet mainly ionic in nature. The comparison with the XPS spectra relative to MnPS{sub 3} and its potassium ...

2008-12-15

209

Heteroepitaxial growth of In-face InN on GaN (0001) by plasma-assisted molecular-beam epitaxy  

International Nuclear Information System (INIS)

The thermodynamic aspects of indium-face InN growth by radio frequency plasma-assisted molecular-beam epitaxy (rf-MBE) and the nucleation of InN on gallium-face GaN (0001) surface were investigated. The rates of InN decomposition and indium desorption from the surface were measured in situ using reflected high-energy electron diffraction and the rf-MBE 'growth window' of In-face InN (0001) was identified. It is shown that sustainable growth can be achieved only when the arrival rate of active nitrogen species on the surface is higher than the arrival rate of indium atoms. The maximum substrate temperature permitting InN growth as a function of the active nitrogen flux was determined. The growth mode of InN on Ga-face GaN (0001) surface was investigated by reflected high-energy electron diffraction and atomic force microscopy. It was found to be of the Volmer-Weber-type for substrate temperatures less than 350 deg. C and of ...

2005-06-01

210

Upgrade of X-ray Magnetic Diffraction Experimental System and Its Application to Ferromagnetic Material  

International Nuclear Information System (INIS)

We have performed X-ray magnetic diffraction (XMD) experiment of ferromagnets at the Photon Factory (PF) of the High Energy Accelerator Research Organization (KEK) in Tsukuba. In this study, we have upgraded the XMD experimental system in order to apply this method to as many samples as possible. Upgrade was made for (1) the X-ray counting system and related measurement program, (2) the electromagnet, and (3) the refrigerator. The performance of the system was enhanced so that (1) the counting rate capability was improved from 104cps to 105cps, (2) the maximum magnetic field was increased from 0.85T to 2.15T, and (3) the lowest sample temperature was reduced from 15K to 5K. The new system was applied to an orbital ordering compound of YTiO3, and we obtained spin magnetic form factor for the reflection plane (010) perpendicular to the b axis. The magnetic field of 2T was needed to saturate the magnetization of YTiO3 along ...

2007-01-19

211

Thickness measurement of Sn-Ag hot dip coatings on Large Hadron Collider Superconducting strands by coulometry  

CERN Document Server

Amperostatic coulometry was applied for the thickness measurement of Sn-Ag hot dip coatings, which comprise an extended Sn-Cu interdiffusion layer. Complementary measurements, notably weight loss, X-ray photoelectron spectroscopy, energy-dispersive X-ray spectroscopy, X-ray fluorescence (XRF), and dynamic secondary ion mass spectroscopy were performed in order to obtain a better interpretation of the coulometry results. Based on the experimental results presented in this article, the three potential changes observed during coulometry measurements are ascribed to (i) the entire dissolution of pure Sn, (ii) the formation of a CuCl salt layer, and (iii) the surface passivation. The measurement of the pure Sn mass is well reproducible despite strong coating thickness variations detected by XRF. Several experimental problems, in particular, a coating undercutting, hamper the determination of the Sn mass in ...

2004-01-01

212

Study on pyrolysing behavior of NiO-SDC composite particles prepared by spray pyrolysis technique  

Energy Technology Data Exchange (ETDEWEB)

The NiO-samaria doped ceria (SDC) composite powders were prepared by spray pyrolysis technique at temperatures between 400 and 1000 C. The variation of the particle structure was investigated by X-ray diffraction (XRD), X-ray absorption fine structure (XAFS), scanning electron microscope (SEM), and transmission electron microscope (TEM)-energy-dispersive X-ray spectroscopy (EDS). The thermal analysis of raw materials was also carried out. The following facts became clear in this study. Ceria and nickel have been already separated at 400 C. Samaria is amorphous phase below 600 C, and is dissolved in ceria at 600 C or higher. Samaria is distributed uniformly inside the particles before dissolving in ceria. The thermal decomposition temperatures of metal nitrate are: cerium < nickel < samarium. The results of these analyses were explained without contradiction. It was found that it is ...

2007-03-15

213

Stereoscopic observations of a solar hard x-ray flare with Ulysses, PVO, GRO and Yohkoh spacecraft  

Energy Technology Data Exchange (ETDEWEB)

Hard X-ray/gamma-ray spectrometers aboard two interplanetary spacecraft, Ulysses and Pioneer Venus Orbiter (PVO), and two near-Earth spacecraft, Yohkoh and Compton Gamma Ray Observatory (GRO/BATSE), are currently in operation. A unique set of circumstances have permitted the observation of the 15 November 1991 (2238 UT) flare by all the four instruments. This intense flare (GOES class X 1.5) was associated with the bright (3B) H-alpha flare located on the disk (S13, W19) in the active region 6919. At the time of the flare, the Ulysses and PVO spacecraft were located respectively 101[degree] and 52[degree] west of the Sun-Earth line. Thus the view angles for the PVO and Ulysses instruments were quite different from those of the near-Earth instruments on GRO and Yohkoh. The preliminary photon energy spectra observed by the four instruments at different times during the flare will be presented and their implications regarding the directivity of ...

1992-01-01

214

Previous heat treatment inducing different plasma nitriding behaviors in martensitic stainless steels  

International Nuclear Information System (INIS)

In this work we report a study of the induced changes in structure and corrosion behavior of martensitic stainless steels nitrided by plasma immersion ion implantation (PI"3) at different previous heat treatments. The samples were characterized by x-ray diffraction and glancing angle x-ray diffraction, scanning electron microscopy, energy dispersive x-ray spectroscopy, and potentiodynamic measurements. Depending on the proportion of retained austenite in the unimplanted material, different phase transformations are obtained at lower and intermediate temperatures of nitrogen implantation. At higher temperatures, the great mobility of the chromium yields CrN segregations like spots in random distribution, and the #alpha#"'-martensite is degraded to#alpha#-Fe (ferrite). The nitrided layer thickness follows a fairly linear relationship with the temperature and a parabolic law with the process time. The ...

2006-09-01

215

Investigation of #alpha#-sialon formation by high temperature X-ray diffraction  

International Nuclear Information System (INIS)

A technique for following sialon formation in situ by high temperature X-ray diffraction (HT-XRD) was developed. The composition chosen for study was an yttrium #alpha#-sialon with x=0.4. Powder compacts containing silicon nitride, aluminum nitride and yttria powders were pre-sintered at 1350 C and then studied by HT-XRD at temperatures between 1450 and 1580 C and nitrogen pressures of 0.11 MPa. The furnace was made from graphite coated with porous silicon nitride/silicon carbide. The coating prevented silicon carbide formation in the sample up to 1600 C. X-ray diffraction results show the formation of a Y_1_0Al_2Si_3O_1_8N_4 phase at 1350 C, which dissolved to form #alpha#-sialon and other phases at higher temperatures. The amounts of #alpha#-sialon formed are similar to the amounts reported by other authors. An empirical method was used for the calculation of activation energy for the silicon nitride to #alpha#-sialon ...

1993-10-04

216

Extreme Ultraviolet Emission from Abell 4059  

CERN Document Server

We present the results of a search for Extreme Ultraviolet emission in A4059, a cluster with an X-ray emitting cluster gas. Our analysis of Extreme Ultraviolet Explorer (EUVE) Deep Survey observations of this cluster shows that it is associated with diffuse EUV emission. Outside the central 2 arcmin radius the entire EUV emission detected is explained by the low energy tail of the X-ray emitting gas. Within the central 2 arcmin region of the cluster we find a deficit of EUV emission compared to that expected from the X-ray gas. This flux deficit is discussed in the context of the cluster's cooling flow. The results derived for A4059 are compared to EUVE results obtained for other clusters such as Coma, Virgo, A1795, and A2199. As part of the study we have carried out a detailed investigation of the stability of the EUVE Deep Survey detector background. Based on long integrations of blank sky over 27 ...

2000-01-01

217

Studies of crystalline CdZnTe radiation detectors and polycrystalline thin film CdTe for X-ray imaging applications  

CERN Document Server

The development of a replacement to the conventional film based X-ray imaging technique is required for many reasons. One possible route for this is the use of a large area film of a suitable semiconductor overlaid on an amorphous silicon readout array. A suitable semiconductor exists in cadmium telluride and its tertiary alloy cadmium zinc telluride. In this thesis the spectroscopic characteristics of commercially available CZT X- and gamma-radiation detectors are established. The electronic, optical, electro-optic, structural and compositional properties of these detectors are then investigated. The attained data is used to infer a greater understanding for the carrier transport in a CZT radiation detector following the interaction of a high energy photon. Following this a method used to fabricate large area films of CdTe on a commercial scale is described. This is cathodic electrodeposition from an aqueous electrolyte. The theory and ...

2001-01-01

218

Optical and X-ray characterization of ferroelectric strontium-bismuth-tantalate (SBT) thin films  

International Nuclear Information System (INIS)

Metal-organic chemical vapor deposition (MOCVD) made layers of strontium-bismuth-tantalate (SBT) were characterized by spectroscopic ellipsometry (SE) using the Adachi model [S. Adachi, Phys. Rev. B 35 (1987) 7454-7463]. The evaluated optical parameters were correlated with the physical and chemical behavior examined by X-ray diffraction (XRD). As a result, it was possible to fit the measured spectra with the Adachi model in a wide range covering the region of the band gap. The Adachi model provides electronic layer parameters like the transition energy E 0 and broadening ?. Our investigations established a correlation between XRD-determined average grain size and the electronic layer parameters.

2006-10-31

219

Neutron star evolution and emission  

Science.gov (United States)

This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The authors investigated the evolution and radiation characteristics of individual neutron stars and stellar systems. The work concentrated on phenomena where new techniques and observations are dramatically enlarging the understanding of stellar phenomena. Part of this project was a study of x-ray and gamma-ray emission from neutron stars and other compact objects. This effort included calculating the thermal x-ray emission from young neutron stars, deriving the radio and gamma-ray emission from active pulsars and modeling intense gamma-ray bursts in distant galaxies. They also measured periodic optical and infrared fluctuations from rotating neutron stars and search for high-energy TeV gamma rays from discrete celestial sources.

1997-08-01

220

Lowering the activation temperature of TiZrV non-evaporable getter films [for LHC  

CERN Document Server

In order to reduce the activation temperature of the TiZrV alloy, thin films of various compositions were produced by three-cathode magnetron sputtering on stainless-steel substrates. For the characterisation of the activation behaviour the surface chemical composition has been monitored by Auger electron spectroscopy during specific in situ thermal cycles. The volume elemental composition of the film has been measured by energy dispersive X-ray spectroscopy and the morphology (crystal structure and size of the crystallites) has been investigated by X-ray diffraction. The criteria indicating the sample quality and its dependence on film structure and chemical composition are presented and discussed. (13 refs).

2001-01-01

221

Load transfer in bovine plexiform bone determined by synchrotron x-ray diffraction.  

Energy Technology Data Exchange (ETDEWEB)

High-energy synchrotron x-ray diffraction (XRD) has been used to quantify load transfer in bovine plexiform bone. By using both wide-angle and small-angle XRD, strains in the mineral as well as the collagen phase of bone were measured as a function of applied compressive stress. We suggest that a greater proportion of the load is borne by the more mineralized woven bone than the lamellar bone as the applied stress increases. With a further increase in stress, load is shed back to the lamellar regions until macroscopic failure occurs. The reported data fit well with reported mechanisms of microdamage accumulation in bovine plexiform bone.

2008-02-01

222

K-shell x-ray production cross sections of selected elements from Ti to Y for 0.5- to 2.5-MeV alpha-particle bombardment  

International Nuclear Information System (INIS)

K-shell x-ray production cross sections and K#beta#/K#alpha# ratios have been measured for thin targets of Ti, V, Cr, Fe, Ni, Cu, Zn, Ga, As, Se, Rb, Sr, and Y for 0.5- to 2.5-MeV alpha particles. The experimental values are compared to the nonrelativistic plane-wave Born approximation (PWBA), the binary-encounter approximation, and the PWBA with binding energy and Coulomb deflection corrections. The PWBA with corrections provides the best agreement with the experimental cross sections.

223

Infrared (IR) vs x-ray power generation in the SLAC Linac Coherent Light Source (LCLS)  

Energy Technology Data Exchange (ETDEWEB)

The LCLS, a Free-Electron Laser (FEL) designed for operation at a first harmonic energy of 300 eV ({lambda} {congruent} 40{Angstrom}) in the Self-Amplified Spontaneous Emission (SASE) regime, will utilize electron bunches compressed down to durations of <0.5ps, or lengths of <150 {mu}. It is natural to inquire whether coherent radiation of this (and longer) wavelength will constitute a significant component of the total coherent output of the FEL. In this paper a determination of a simple upper bound on the IR that can be generated by the compressed bunches is outlines. Under the assumed operating parameters of the LCLS undulator, it is shown that that IR component of the coherent output should be strongly dominated by the x-ray component.

1993-05-01

224

Electrical properties and x-ray diffraction of wood and wood plastic composite (WPC)  

Energy Technology Data Exchange (ETDEWEB)

Wood plastic composite (WPC) of kadom, simul, mango and debdaro were prepared with two monomers methylmethacrylate (MMA) and butylmethacrylate (BMA) using high energy ionizing radiation. X-ray diffraction and scanning electron microscope (SEM) studies reveal that significant grafting occurred with wood fiber. Electric properties like resistivity and dielectric constant of both wood and WPC were measured under different moisture contents and relative humidities. The resistivities of wood decreased dramatically with increase of moisture content, but those of WPC decreased very slowly with moisture content. The dielectric constant of wood increased significantly with moisture content but no significant difference was observed in the case of WPC within the range of moisture contents studied. The dielectric constants of untreated wood also increased with their densities. (author).

1991-01-01

225

Corrosion of gold bridgewire in electronic components  

Energy Technology Data Exchange (ETDEWEB)

Accelerated aging tests on gold bridgewired detonator assemblies to determine compatibility of the Au and Pd-In-Sn solder with the organic explosive, PENT, have revealed an unusual corrosion process. These tests, conducted at 74/sup 0/C and 54/sup 0/C indicated a preferential attack of the gold. A matrix of corrosion test units was established to study this corrosion problem with accelerating temperatures up to 100/sup 0/C. Scanning electron microscopy (SEM), energy dispersive x-ray (EDX), and x-ray diffraction techniques were used to determine the extent of the corrosion and identify the corrosion products. Results indicate the preferential attack of the gold was due to HCN formed by decomposition of the explosive powder (PETN) at high temperatures. Other associated reactions were also observed including subsequent attack of the solder by the gold corrosion product and degradation of the plastic header.

1986-01-01

226

Cluster model for lattice distortion effects on electronic structure: VO and VO_2  

International Nuclear Information System (INIS)

Molecular cluster predictions for electronic energy levels, wave functions, momentum densities, and Compton profiles of VO and VO_2 are examined within the Hartree-Fock-Slater model. VO_6 clusters are treated in O/subh/, D_4/subh/, and D_2/subh/ symmetry to obtain quantitative relations between distortion parameters and level shifts and splittings. Effects of the crystal environment are taken into account by a potential field. Results for VO are consistent with the augmented plane-wave band calculation of Mattheiss and x-ray emission data; the VO_2 levels are in good agreement with x-ray photoelectron spectroscopy data. A sizable anisotropy is predicted for the Compton profile of VO and VO_2.

227

Application of digital radiography to diagnosis of laryngeal diseases  

International Nuclear Information System (INIS)

Fuji Computed Radiography (FCR) is a new system of digital radiography that is based on the latest computer technologies. We applied this FCR system to the X-ray diagnosis of the laryngeal disease. Twenty patients with various laryngeal diseases were evaluated by both FCR frontal tomography and conventional screen-film frontal tomography under the same exposure condition. Both tomograms were then compared on the subject of the clarity of delineation of laryngeal structures. As the result, FCR tomograms revealed the feature of the laryngeal lumen and cartilages more clearly than conventional tomograms. In addition, energy subtraction method, which is one of FCR image processing systems, was presented as a new technical procedure to extinguish cervical spine shadows in plain anteroposterior laryngeal X-photograph. We stress that FCR system is the suitable procedure for X-ray analysis of laryngeal diseases, especially in the ...

1986-01-01

228

Camera for coherent diffractive imaging and holography with a soft-x-ray free-electron laser  

International Nuclear Information System (INIS)

We describe a camera to record coherent scattering patterns with a soft-x-ray free-electron laser (FEL). The camera consists of a laterally graded multilayer mirror, which reflects the diffraction pattern onto a CCD detector. The mirror acts as a bandpass filter for both the wavelength and the angle, which isolates the desired scattering pattern from nonsample scattering or incoherent emission from the sample. The mirror also solves the particular problem of the extreme intensity of the FEL pulses, which are focused to greater than 10"1"4 W/cm"2. The strong undiffracted pulse passes through a hole in the mirror and propagates onto a beam dump at a distance behind the instrument rather than interacting with a beam stop placed near the CCD. The camera concept is extendable for the full range of the fundamental wavelength of the free electron laser in Hamburg (FLASH) FEL (i.e., between 6 and 60 nm) and into the water window. ...

2008-04-01

229

Al/sub 0. 3/Ga/sub 0. 7/P/sub 0. 01/As/sub 0. 99/ GaAs laser heterostructures grown by molecular beam epitaxy  

Science.gov (United States)

Stresses commonly present in AlGaAs/GaAs laser heterostructures were reduced using Molecular Beam Epitaxy grown Al/sub 0.3/Ga/sub 0.7/P/sub 0.01/As/sub 0.99/ cladding layers. The Al/sub 0.3/Ga/sub 0.7/P/sub 0.01/As/sub 0.99/ alloy was grown using an incident P/sub 2/ flux of roughly-equal1 x 10/sup 14//cm/sup 2/ indicating a sticking coefficient of 0.1 at a substrate temperature of 600 /sup 0/C. X-ray automatic Bragg angle control curvature measurements were used to monitor the residual heteroepitaxial stress. Broadened double crystal x-ray linewidths indicated the occurrence of alloy grading and broadened interfaces. The effects of P concentration and film thickness on stress and on the existence of a misfit dislocation grid are discussed.

1982-09-01

230

Spectroscopic investigation of the charge dynamics of heavy ions penetrating solid and gaseous targets  

Energy Technology Data Exchange (ETDEWEB)

This thesis presents the study of the slowing down process of fast heavy ions inside matter. In the framework of this research, the influence of the target density on the stopping process is investigated. Experiments on the interaction of {sup 48}Ca{sup 6+}-{sup 48}Ca{sup 10+} and {sup 26}Mg{sup 5+} ion beams with initial energies of 11.4 MeV/u and 5.9 MeV/u with solid and gaseous targets have been carried out. A novel diagnostic method, X-ray spectroscopy of K-shell projectile radiation, is used to determine the ion charge state in relation to its velocity during the penetration of fast heavy ions inside the stopping material. A spatially resolved analysis of the projectile and target radiation in solids is achieved for the first time. The application of low-density silica aerogels as stopping media provided a stretching of the ion stopping length by 20 - 100 times in comparison with solid quartz. The Doppler Effect ...

2007-01-15

231

Semi-empirical simulation of thermoluminescent response under different filter geometries; Simulacao semi-empirica da resposta termoluminescente sob diferentes geometrias de filtro  

Energy Technology Data Exchange (ETDEWEB)

Many thermoluminescent materials has been developed and used for photon personal dosimetry but no one has all desired characteristics alone. These characteristics include robustness, high sensitivity, energy photon independence, large range of photon energy detection, good reproducibility, small fading and simple glow curve with peaks above 150 deg C. Calcium Sulfate Dysprosium doped (CaSO{sub 4}:Dy) phosphor Thermoluminescent Dosimeter (TLD) has been used by many laboratories, mainly in Brazil and India. Another interesting phosphor is Calcium Fluoride (CaF{sub 2}). These phosphor advantages begin to be more required and its disadvantages have became more apparent, in a global market more and more competitive. These phosphors are used in environmental and area monitoring, once they present more sensibility than other phosphors, like LiF:Mg. Theirs mainly disadvantage is a strong energetic dependence response, which must be corrected for theirs ...

2006-07-01

232

Surface Roughness of Stainless Steel Bender Mirrors for FocusingSoft X-rays  

Energy Technology Data Exchange (ETDEWEB)

We have used polished stainless steel as a mirror substrate to provide focusing of soft x-rays in grazing incidence reflection. The substrate is bent to an elliptical shape with large curvature and high stresses in the substrate require a strong elastic material. Conventional material choices of silicon or of glass will not withstand the stress required. The use of steel allows the substrates to be polished and installed flat, using screws in tapped holes. The ultra-high-vacuum bender mechanism is motorized and computer controlled. These mirrors are used to deliver focused beams of soft x-rays onto the surface of a sample for experiments at the Advanced Light Source (ALS). They provide an illumination field that can be as small as the mirror demagnification allows, for localized study, and can be enlarged, under computer control,for survey measurements over areas of the surface up to several millimeters. The critical issue ...

2005-10-11

233

Comparison of enhanced device response and predicted x-ray dose enhancement effects on MOS oxides  

Energy Technology Data Exchange (ETDEWEB)

The response of MOS capacitors to low- and medium-energy x-ray irradiation is investigated as a function of gate material (TaSi or Al), oxide thickness, and electric field. Measured device response is compared with predictions based on discrete ordinates and Monte Carlo code simulations of dose enhancement effects, coupled with recent estimates of electron-hole recombination in MOS oxides. In comparisons of 10-keV x-ray and Co-60 irradiations of Al-gate MOS capacitors at an oxide electric field of 1 MV/cm, it is found that predictions and experiments agree to within better than 20 percent for oxide thicknesses ranging from 35 to 1060 nm. For capacitors having TaSi/Al gates, predictions and experiments agree to within better than 30 percent at 1 MV/cm, with the largest differences occurring for 35-nm gate oxides. At other electric fields, the disagreement between experiment and prediction increases significantly for both Al- ...

1988-12-01

234

Comparison of enhanced device response and predicted x-ray dose enhancement effects on MOS oxides  

International Nuclear Information System (INIS)

The response of MOS capacitors to low- and medium-energy x-ray irradiation is investigated as a function of gate material (TaSi or Al), oxide thickness, and electric field. Measured device response is compared with predictions based on discrete ordinates and Monte Carlo code simulations of dose enhancement effects, coupled with recent estimates of electron-hole recombination in MOS oxides. In comparisons of 10-keV x-ray and Co-60 irradiations of Al-gate MOS capacitors at an oxide electric field of 1 MV/cm, it is found that predictions and experiments agree to within better than 20 percent for oxide thicknesses ranging from 35 to 1060 nm. For capacitors having TaSi/Al gates, predictions and experiments agree to within better than 30 percent at 1 MV/cm, with the largest differences occurring for 35-nm gate oxides. At other electric fields, the disagreement between experiment and prediction increases significantly for both Al- ...

1988-07-12

235

Application of isotope-excitation x-ray fluorescence (XRF) analysis for aluminium production  

International Nuclear Information System (INIS)

An energy sensitive Si(Li) detector XRF analyzer built by ATOMKI, Hungary, has been applied for various analytical purposes in alumina production at the Almasfuezitoe Alumina Company, Hungary. Specifically, the CaO content in red mud was determined by the new XRF technique using isotope excitation sources. The analysis of other components is under way. (R.P.).

236

Analysis of TL glow curves in differently doped LiF:Mg,Ti  

International Nuclear Information System (INIS)

A computerised curve-fitting method was developed to calculate the trapping parameters in LiF TLD-100 and LiF:Mg, Ti. After irradiation in a "6"0Co field and with X rays emitted at different voltages the TL process is best described by first-order kinetics. A dependence of the trapping parameters on both the concentration of Mg and Ti and photon energy was detected. (author).

237

Phase imaging using laser-produced X-ray sources  

International Nuclear Information System (INIS)

A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. The authors established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging

2000-08-01

238

Direct Comparison of the X-Ray Emission and Absorption of Cerium Oxide  

Energy Technology Data Exchange (ETDEWEB)

Bremstrahlung Isochromat Spectroscopy (BIS). The XES spectra were collected using a Specs electron gun for the excitation and the XES 350 grating monochromator and channel plate system from Scienta as the photon detection. Spectra were collected in 'normal mode,' where the electron gun kinetic energy (KE) and the energy position of the center of the channel plate were both fixed and the energy distribution in the photon (hv) spectrum was derived from the intensities distributed across the channel plate detector in the energy dispersal direction. The polycrystalline Ce sample was oxidized by exposure to air at ambient pressures. After introduction to the ultra-high vacuum system, the oxidized sample was bombarded with Ar, to clean the topmost surface region and stabilize the surface and near surface regions. Although CeO{sub 2} would be the thermodynamically preferred composition in an ...

2010-11-24

239

Study of penetration depth for V"+ with low energy implanted in peanut seeds  

International Nuclear Information System (INIS)

The penetration depth and concentration distribution for vanadium ions with low energy implanted into the dry peanut seeds is determined by scanning electron microscope and X-ray energy dispersion spectrometer. The results show that the depth-concentration distribution is a Gaussian distribution with a long tail and the maximum penetration depth is about 13.6 #mu#m for V"+ with 200 keV in cotyledon of the peanut. The experimental result of the implanted V"+ range in the peanut seeds is compared with the calculating value of the TRIM95

2002-11-01

240

X-ray magnetic circular dichroism measurements using an X-ray phase retarder on the BM25 A-SpLine beamline at the ESRF  

UK PubMed Central (United Kingdom)

Circularly polarized X-rays produced by a diamond X-ray phase retarder of thickness 0.5 mm in the Laue transmission configuration have been used for recording X-ray magnetic circular dichroism...Full Text Available

2010-05-01

241

Low-energy high-current electron beam generation in plasma systems and beam-plasma interaction  

International Nuclear Information System (INIS)

... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,

2006-09-11

242

Materials research and beam line operation utilizing NSLS. Progress report  

Energy Technology Data Exchange (ETDEWEB)

MATRIX, a participating research team of Midwest x-ray scattering specialists, continues to operate beam line X-18A at NSLS. Operations of this line now provides state-of-the-art capabilities to a wide range of people in the Materials Science and Engineering research community. Improvements of the beam line continue to be a focus of MATRIX. Throughout this past year the emphasis has been shifting towards improvement in ``user friendly`` aspects. Simplified control operations and a shift to single-user personal computer has been a major part of the effort. Over the past year the full 242 operational days were utilized. Beam line test and evaluation consumed 21 days with eight MATRIX groups combining to use 170 days. General user demand for use of the beam line continues to be strong and three groups were provided 51 operating days. Research production has been growing as NSLS and the ...

1991-10-01

243

M-shell x-ray production by 0.6--4.0-MeV protons in ten elements from hafnium to thorium  

International Nuclear Information System (INIS)

M-shell x-ray production cross sections for selected heavy elements, namely, _7_2Hf, _7_3Ta, _7_4W, _7_5Re, _7_6Os, _7_7Ir, _7_8Pt, _7_9Au, _8_3Bi, and _9_0Th, were measured for protons of energy 0.6--4.0 MeV. The experimental results are compared with the predictions of the first Born and semiclassical approximations for M-shell ionization; these data are also compared with the theory that accounts for the projectile's energy loss and Coulomb deflection as well as for the target's M-shell electron perturbed stationary state and relativistic nature (ECPSSR). Generally, fair agreement between the data and the ECPSSR theory is found. Some systematical discrepancies observed for the lightest elements (Hf, Ta, and W) are explained as possible ambiguities in the M-shell Coster-Kronig factors and fluorescence yields, which were used to convert theoretical M-subshell ionization cross sections to the total ...

244

Normalized noise power spectrum of full field digital mammography detector system  

International Nuclear Information System (INIS)

Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)

245

Normalized Noise Power Spectrum of Full Field Digital Mammography System  

International Nuclear Information System (INIS)

A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.

2010-01-05

246

Microstructure and mechanical properties of magnesium alloy AZ31B laser beam welds  

International Nuclear Information System (INIS)

Microstructure and properties of a Mg AZ31B laser beam weld without filler are studied using electron microscopy, X-ray diffraction and mechanical tests. The microstructure of the weld is characterized by a narrow heat affected zone, columnar grains and precipitate coarsening in the fusion zone. Texture in the fusion zone is significantly different from the texture of the base material. The residual stress distribution observed is similar at the top and the bottom of the weld, maximum tensile residual stress values are observed in the fusion zone. Tensile tests reveal differences in the mechanical behavior of the fusion zone and the parent material, which can be related to the differences of texture and the resulting deformation mechanisms.

2008-06-25

247

Ion beam induced damage and element loss during a microanalysis of biological tissue  

Energy Technology Data Exchange (ETDEWEB)

Specimen damage and element loss induced by 3 MeV proton and 2 MeV alpha particle bombardment of thin sections of freeze-dried kidney tissue and embedding medium have been studied. Yields of ions scattered from H and C, and characteristic X-rays were measured versus accumulated charge, for curent densities in the range from 8x10{sup -15} to 1.1x10{sup -11} A/{mu}m{sup 2}. Structural damage, dissolouration and loss of S, Cl, C and H have been observed. Implications of this study for ion beam microanalysis of biological tissues are discussed with particular reference to the results for H loss. (orig.).

1991-03-01

248

Investigation on corrosion resistance of amorphous films prepared by ion beam mixing  

International Nuclear Information System (INIS)

Fe-Cr amorphous films have been formed by both in situ evaporation of multilayered films and ion beam mixing in a target chamber of a 200 keV implanter. The effects of Cr content and ion irradiation on the amorphization of films were examined by transmission electron microscope (TEM). Corrosion of film was investigated by means of a potential dynamic polarization. Corrosion resistance of amorphous film in 0.5 mol H-2SO-4 solution is considerably increased than that of pure iron. Using X ray photoelectron spectroscopy (XPS) corrosion resistance in atmosphere of amorphous Fe-Cr passive films formed by P"+ mixing was studied. Results show that the richness of Cr and P exist at the surface of Fe-Cr film.

1991-01-01

249

Effect of treatment time on low temperature plasma nitriding of stainless steel by saddle field neutral fast atom beam source  

International Nuclear Information System (INIS)

Recent research carried out in laboratories showed that Saddle field neutral fast atom beam source is a promising method for nitriding of stainless steel. In the present work, the effect of treatment time on the microstructural and mechanical properties of plasma-nitrided stainless steel sample was investigated by this new method. Plasma nitriding was carried out at 420 deg. C and at a pressure of 0.1 Pa for a time range of 1 to 12 h. SEM-EDX, microhardness tests, optical microscopy and X-ray diffraction (XRD) were used to evaluate the mechanical and structural properties of the nitrided layer. It was found that nitriding time has a pronounced effect on the structural and mechanical properties of low-temperature plasma-nitrided samples and produced a precipitation-free thin hard nitrided layer within a short processing time.

2006-09-25

250

Micro area analysis and measurement of electronic device material (challenge to utmost limits). Characterization of interface elect`ron structure by photon-and electron-spectroscopies; Denshi debaisu yo zairyo no bisho ryoiki bunseki-keisoku (kyokugen eno chosen). Koshi-denshi bunkoho ni yoru kaimen denshi jotai hyoka  

Energy Technology Data Exchange (ETDEWEB)

A method for detecting electrons emitted as secondary particles by photon incidence to a specimen, as well as a method of using the photons emitted by electron incidence as detecting particles are explained. Pd-Si(100)2{times}1 system is adopted for a case study of using photo-electron spectroscopy where synchrotron emitted light in soft X-ray region is used as the incident light. Pd atoms are deposited little by little on clean Si surface to investigate the electron structure of the surface, and the interface electron structure after bonded formation of Pd(thin film)-Si(substrate) is estimated. Radiation soft X-ray spectroscopy is employed to observe the real state of the bonded interface of Pd(thin film)-Si(substrate) prepared by depositing Pd film in a short period of time. In the case of radiation soft X-ray spectroscopy with electron beam excitation, bonded system of thin film and substrate can be ...

1995-07-20

251

K and L x-ray production cross sections excited by 14.00--34.16 MeV #alpha#-particle beams  

International Nuclear Information System (INIS)

K and L-shell x-ray production cross sections were measured using #alpha#-particle beams of 14.00 to 34.16 MeV. The K-shell measurements ranged from Z = 20 to Z = 50 and included Ca, Sc, Ti, V, Fe, Ni, Cu, Zn, Ga, Br, Rb, Sr, Y, Mo, Ag, In, and Sn while the L-shell measurements ranged from Z = 55 to Z = 92 and included Cs, Ba, Ce, Gd, Tm, Lu, Au, Pb, Th, and U. Thin metallic foils were used for the measurements and corrections for self-attenuation were negligible. A liquid nitrogen cooled Si(Li) detector and associated pulsed optical electronics were used in detecting x-rays. Absolute cross sections with an uncertainty of +-10 percent are presented for the elements measured. Also smoothed cross sections are presented which were generated by a three term polynomial fit of the experimental data points. By use of available fluorescence yields the K-shell data were converted to ionization cross sections and compared to various ...

252

Analyses of superficial and depth doses in intraoral radiology  

Energy Technology Data Exchange (ETDEWEB)

In this work dosimetric analysis using thermoluminescence technique to study the beams characteristics of x-rays employed in dental radiology has been carried out. The obtained results with CaSO{sub 4}:Dy thermoluminescent dosimeters (TLD) were compared to the doses obtained with parallel-plates ionization chamber. Dosimetric evaluations were also done using radiographic films of large dimensions. The x-rays equipments analyzed were installed in the radiological services of Odontology Department of Sergipe Federal University (U.F.S.). Depending on the anatomical region to be examined the proper exposure time was select, for a fix voltage of 70 kV. The results with TLD and ionization chamber have been determined to female and male individuals. The intraoral regions analysed were the peri apical of the incisors, molar and pre-molar teeth and the occlusive region. These regions were simulated using acrylic plates absorbers ...

2006-07-01

253

Study of the crystallographic architecture of corals at the nanoscale by scanning transmission X-ray microscopy and transmission electron microscopy.  

Science.gov (United States)

We have investigated the nanotexture and crystallographic orientation of aragonite in a coral skeleton using synchrotron-based scanning transmission X-ray microscopy (STXM) and transmission electron microscopy (TEM). Polarization-dependent STXM imaging at 40-nm spatial resolution was used to obtain an orientation map of the c-axis of aragonite on a focused ion beam milled ultrathin section of a Porites coral. This imaging showed that one of the basic units of coral skeletons, referred to as the center of calcification (COC), consists of a cluster of 100-nm aragonite globules crystallographically aligned over several micrometers with a fan-like distribution and with the properties of single crystals at the mesoscale. The remainder of the skeleton consists of aragonite single-crystal fibers in crystallographic continuity with the nanoglobules comprising the COC. Our observation provides information on the nm-scale processes that led to biomineral ...

2011-05-05

254

Measurement of L X-ray fluorescence cross-sections for elements with 45 Z50 using synchrotron radiation at 8keV  

British Library Electronic Table of Contents (United Kingdom)

The L shell fluorescence cross-sections of the elements in range 45Z50 have been determined at 8keV using Synchrotron radiation. The individual L X-ray photons, Ll, La, LbI, LbII, LgI and LgII produced in the target were measured with high resolution Si(Li) detector. The experimental set-up provided a low background by using linearly polarized monoenergetic photon beam, improving the signal-to-noise ratio. The experimental cross-sections obtained in this work were compared with available experimental data from Scofield [1,2] Krause [3,4] and Scofield and Puri et al. [5,6]. These experimental values closely agree with the theoretical values calculated using Scofield and Krause data, except for the case of Lg, where values measured of this work are slighter higher.

2011-01-01

255

Broad-band stigmatic spectrograph for the soft x-ray range  

International Nuclear Information System (INIS)

We describe a panoramic stigmatic spectrograph comprising a grazing-incidence toroidal mirror and a large-aperture free-standing transmission diffraction grating (5000 lines mm-1 ). Two spectrograph versions were constructed, with grazing angles of 7.6 and 40 and the short-wavelength spectral limits near 4 and 1.5 nm. The spectrograph aberrations were studied by numerical ray tracing. The spectrograph was used to record line and quasi-continuous spectra (1.5 - 30 nm) of multiply charged ions in a plasma generated by the second-harmonic pulses of an yttrium aluminate laser (Q = 0.15 J, ? = 5 ns, ? = 0.54 ?m, repetition rate = 0.5 Hz). In combination with a laser-produced plasma radiation source, the arrangement was used to characterise soft x-ray optical components and to generate collimated beams of polarised radiation in the 14 - 20 nm range. (laser applications and other topics in quantum electronics)

1998-09-30

256

Automatic system for measuring dose-area product (DAP) in ROI fluoroscopy  

Energy Technology Data Exchange (ETDEWEB)

A computerized system for monitoring dose-area product (DAP) has been developed for region of interest (ROI) fluoroscopy in which patient exposure is reduced using an x-ray attenuating filter with an aperture. The system includes an IBM compatible computer which is connected through an IEEE-488 interface to an electrometer which measures the charge from a DAP ionization chamber. A digital input/output board connects the computer to the filter placement device to determine whether the filter is in or out of the beam, and to the x-ray generator to determine when the exposure is due to spot filming. The computer logs the DAP from conventional fluoroscopy, ROI fluoroscopy and spot filming separately, applying the appropriate calibration factor for each. Measured DAPs, fluoroscopic DAP rates and exposure times are displayed in real-time. The system has been installed in a GI fluoroscopic room so that the dose-reduction potential ...

1997-04-01

257

Creating an EPICS Based Test Stand Development System for a BPM Digitizer of the Linac Coherent Light Source  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) is required to deliver a high quality electron beam for producing coherent X-rays. As a result, high resolution beam position monitoring is required. The Beam Position Monitor (BPM) digitizer acquires analog signals from the beam line and digitizes them to obtain beam position data. Although Matlab is currently being used to test the BPM digitizer?s functions and capability, the Controls Department at SLAC prefers to use Experimental Physics and Industrial Control Systems (EPICS). This paper discusses the transition of providing similar as well as enhanced functionalities, than those offered by Matlab, to test the digitizer. Altogether, the improved test stand development system can perform mathematical and statistical calculations with the waveform signals acquired from the digitizer and compute the fast Fourier transform ...

2011-06-22

258

Probing the Geometry and Physics of the Emission Region in Active Galactic Nuclei using hard X-ray & Gamma-ray Observations  

Energy Technology Data Exchange (ETDEWEB)

The X-ray spectra of {approx}200 AGN collected from Swift-BAT were analyzed to test the Unified Model for AGN. Specifically, the photon indices, high energy cutoffs, and reflection components of Sy1 and Sy2 were compared. Under the Unified Model, the photon indices and reflection components for Sy1 should be larger than Sy2 and the high energy cutoffs should be the same. Fitting a simple power law model to the sample spectra proved to be insufficient. The PEXRAV model fit the spectra of the Sy1 and Sy2 significantly better, indicating that a reflection component and/or high energy cutoff exists as the Unified Model expects. Using both the simple power law and PEXRAV models it was concluded that in the population studied, Sy1 had a larger photon index than Sy2, as expected by the Unified Model. For Sy1 and Sy2, the reflection components were found to be compatible, but given the large errors, this ...

2010-08-25

259

Electronic structure of KTiOAsO_4: A comparative study by the full potential linearized augmented plane wave method, X-ray emission spectroscopy and X-ray photoelectron spectroscopy  

International Nuclear Information System (INIS)

First-principles self-consistent band-structure calculations of potassium titanyl arsenate, KTiOAsO_4 (KTA), have been made using the full potential linearized augmented plane wave (FP-LAPW) method. Total and partial densities of states of the constituent atoms of KTA have been derived. The results obtained show that the valence band of KTA is dominated by contributions of the O 2p-like states, while the Ti 3d-like states are the main contributors into the conduction band of the compound. Additionally, the FP-LAPW calculations have revealed that potassium atoms are highly ionized in KTA. In the present work, the X-ray emission spectroscopy (XES) and X-ray photoelectron spectroscopy (XPS) methods were also employed to investigate experimentally the electronic structure of potassium titanyl arsenate. For the mentioned compound, the XES K Ll, Ti L#alpha#, As K#beta#_2 and O K#alpha# bands reflecting the valence K s-, Ti s,d-, As p- and O p-like ...

2009-05-27

260

X-ray stars in globular clusters  

Science.gov (United States)

The properties and kinetics of x-ray stars in globular clusters are described. Locations, configurations, star evolution, massive close binary systems, various mechanisms, and the x-ray burster properties are included. (JFP)

1977-10-01

261

Position-sensitive proportional counter for space-based X-ray imaging studies  

International Nuclear Information System (INIS)

ASTROSAT, India's first dedicated astronomy satellite is slated for launch in 2007. The primary science objective of ASTROSAT is to explore the Universe using broad-band instruments covering optical, UV, soft X-ray and hard X-ray studies

2005-03-01

262

Nanocrystalline #beta#-sialon by reactive sintering of a SiO_2-AlN mixture subjected to high-energy ball milling  

International Nuclear Information System (INIS)

A mixture of powders of silica and aluminum nitride is subjected to high-energy ball milling for different milling times. This material is subsequently compacted by uniaxial pressing and sintered at 1450 deg. C. The resulting pellets are crushed and analysed by X-ray diffraction. For short milling times, the amount of phase transformation is minimal and the resulting material mostly consists of cristobalite and aluminum nitride. For long milling times, nanocrystalline #beta#-SiAl_2O_2N_2 is mainly produced.

2005-04-05

263

Applications of Cerius2, software of molecular simulation; Aplicaciones de Cerius2, software de simulacion molecular  

Energy Technology Data Exchange (ETDEWEB)

Most of the investigations have a theoretical sustenance based on molecular simulation. The area of application of molecular simulation is very wide, in the Materials Technology Department assigned to the Applied Sciences Management have been treated problems about metallic nano structures, glasses, interfaces, and molecules, to sustain and to explain some of the experimental results. Energy calculations are carried out to determine minimum energy structures, for later on to carry out calculations of some of their properties; as well as the images simulation of Electron microscopy and X-ray diffraction. (Author)

2007-07-01

264

Photoacoustic response to X-ray absorption in copper and brass  

Energy Technology Data Exchange (ETDEWEB)

The X-ray photoacoustic spectra of copper and brass (64.7 wt.% Cu and 35.3 wt.% Zn) have been measured at XANES (X-ray absorption near-edge structure) regions using synchrotron radiation. These spectra were compared with optical density of X-ray spectra. It is shown that the information derived from XANES is also included in the X-ray photoacoustic spectrum which reflects the heat production processes in copper and brass. However, the results showed that the increases and changes of the photoacoustic signal were different from those of the X-ray absorption coefficient at XANES regions. (author).

1990-09-01

265

Generation of microwaves and hard X-rays in a flash X-ray tube  

Energy Technology Data Exchange (ETDEWEB)

High interelectrode voltage peaks have been observed simultaneously with the emission of hard X-ray bursts from a flash X-ray tube. The magnitude of the voltage peaks may exceed twice the initial charging voltage. It has also been observed that the discharge emits bursts of X-and P-band microwaves radiation which are coincident with the emission of the hard X-ray bursts. The results indicate that the microwaves and X-rays have a common origin in discharge plasma movements and an acceleration model for electrons in the plasma is presented as one possible explanation of the observed phenomena.

1982-01-01

266

Recent Progress in CdTe and CdZnTe Detectors  

CERN Document Server

Cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) have been regarded as promising semiconductor materials for hard X-ray and Gamma-ray detection. The high atomic number of the materials (Z_{Cd} =48, Z_{Te} =52) gives a high quantum efficiency in comparison with Si. The large band-gap energy (Eg ~ 1.5 eV) allows us to operate the detector at room temperature. However, a considerable amount of charge loss in these detectors produces a reduced energy resolution. This problem arises due to the low mobility and short lifetime of holes. Recently, significant improvements have been achieved to improve the spectral properties based on the advances in the production of crystals and in the design of electrodes. In this overview talk, we summarize (1) advantages and disadvantages of CdTe and CdZnTe semiconductor detectors and (2) technique for improving energy resolution and photopeak efficiencies. ...

2001-01-01

267

K beta X-ray transition energies of M-shell-ionized ions of Ti through Ni in a plasma  

Energy Technology Data Exchange (ETDEWEB)

K beta X-ray lines from partially M-shell-ionized ions of titanium through nickel which are produced in vacuum-spark plasmas have been observed systematically for the first time, using a high-resolution curved-crystal spectrometer. Each K beta line is clearly separated into its corresponding charge state. As a result, it is possible to measure the K beta-type transition energies of the M-shell-ionized ions. The transition energies accurately determined are compared with those calculated for iron ions, and the agreement is excellent except for ions having some additional 3d outer-shell electrons or 3s inner-shell vacancies. The square root of the K beta transition frequency is expressed as a linear function of the nuclear charge for isoelectronic sequences. The effective nuclear charges have been also determined for each K beta transition. The 3p electrons do not affect the effective nuclear charges. 10 references.

1985-05-01

268

x - NASA Technical Reports Server  

Science.gov (United States)

Mar 1, 2011 ... Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation ...

270

NASA Technical Reports Server - Radionuclide X-ray fluorescence ...  

Science.gov (United States)

Aug 1, 1972 ... The principles of radionuclide excitation of X-ray fluorescence radiation and its application in analytic chemistry are discussed.

271

A comparison of the X-ray properties of X Per and gamma Cas  

Energy Technology Data Exchange (ETDEWEB)

The X-ray properties of the main sequence Be stars conclude that they are a widely separated binary system containing an accreting neutron star.

1982-04-01

272

REQUIREMENTS AND GUIDELINES FOR NSLS EXPERIMENTAL BEAM LINE VACUUM SYSTEMS-REVISION B.  

Energy Technology Data Exchange (ETDEWEB)

Typical beam lines are comprised of an assembly of vacuum valves and shutters referred to as a ''front end'', optical elements to monochromatize, focus and split the photon beam, and an experimental area where a target sample is placed into the photon beam and data from the interaction is detected and recorded. Windows are used to separate sections of beam lines that are not compatible with storage ring ultra high vacuum. Some experimental beam lines share a common vacuum with storage rings. Sections of beam lines are only allowed to vent up to atmospheric pressure using pure nitrogen gas after a vacuum barrier is established to protect ring vacuum. The front end may only be bled up when there is no current in the machine. This is especially true on the VUV storage ring where for most experiments, windows are not used. For the ...

1999-05-01

273

High energy beams of radioactive nuclei and their biomedical applications  

Energy Technology Data Exchange (ETDEWEB)

It is possible to produce energetic beams of radioactive nuclei, as secondary beams, from the heavy-particle compound accelerator called BEVALAC. These beams can be focused into experimental areas without significant contamination using suitable magnetic filters and proper beam-optics. Properly selected high-energy beams of radioactive nuclei (those which defay by positron emission) can provide a truly unique opportunity to evaluate the effectiveness of these beams in localizing the Bragg peak on a tumor volume - necessary in heavy-particle therapy. Preliminary data are presented here to demonstrate the possible use of these beams in radiotherapy treatment-planning verification.

1981-04-01

274

Variability and spectral modeling of the hard X-ray emission of GX 339-4 in a bright low/hard state  

CERN Document Server

We study the high-energy emission of the Galactic black hole candidate GX 339-4 using INTEGRAL/SPI and simultaneous RXTE/PCA data. By the end of January 2007, when it reached its peak luminosity in hard X-rays, the source was in a bright hard state. The SPI data from this period show a good signal to noise ratio, allowing a detailed study of the spectral energy distribution up to several hundred keV. As a main result, we report on the detection of a variable hard spectral feature (>150 keV) which represents a significant excess with respect to the cutoff power law shape of the spectrum. The SPI data suggest that the intensity of this feature is positively correlated with the 25 - 50 keV luminosity of the source and the associated variability time scale is shorter than 7 hours. The simultaneous PCA data, however, show no significant change in the spectral shape, indicating that the source is not undergoing a canonical ...

2010-01-01

275

The XMM-Newton wide-field survey in the COSMOS field. IV: X-ray spectral properties of Active Galactic Nuclei  

CERN Document Server

We present a detailed spectral analysis of point-like X-ray sources in the XMM-COSMOS field. Our sample of 135 sources only includes those that have more than 100 net counts in the 0.3-10 keV energy band and have been identified through optical spectroscopy. The majority of the sources are well described by a simple power-law model with either no absorption (76%) or a significant intrinsic, absorbing column (20%).As expected, the distribution of intrinsic absorbing column densities is markedly different between AGN with or without broad optical emission lines. We find within our sample four Type-2 QSOs candidates (L_X > 10^44 erg/s, N_H > 10^22 cm^-2), with a spectral energy distribution well reproduced by a composite Seyfert-2 spectrum, that demonstrates the strength of the wide field XMM/COSMOS survey to detect these rare and underrepresented sources.

2006-01-01

276

Local structure of Ca dopant in BaTiO_3 by Ca K-edge X-ray absorption near-edge structure and first-principles calculations  

International Nuclear Information System (INIS)

The local environment of Ca dopants in barium titanate, BaTiO_3, is investigated by Ca K-edge X-ray absorption near-edge structure (XANES) spectroscopy. In conjunction with experiments, first-principles calculations by two methods are systematically made. The projector-augmented wave (PAW) method is used to optimize the local structure and obtain the formation energy. The augmented plane wave plus local orbitals method is adopted to obtain theoretical XANES spectra. A comparison between experimental and theoretical XANES spectra shows that Ca dopants are located at the Ba"2"+ sites forming Ca"2"+. Formation energy calculations of Ca doped BaTiO_3 by the PAW method also give the same results. The Ca atom in BaTiO_3 is off-centering in comparison with the Ba site in BaTiO_3. The off-centering of Ca atom is newly revealed by the combination of XANES spectroscopy and first-principles DFT calculations.

2010-06-01

277

A facile one-pot hydrothermal method to prepare europium-doped titania hollow phosphors and their sensitized luminescence properties  

British Library Electronic Table of Contents (United Kingdom)

Monodisperse europium-activated titania hollow phosphors had been synthesized by a facile one-pot hydrothermal method using carbon spheres as hard templates. Samples were characterized by X-ray powder diffraction, transmission electron microscopy, X-ray photoelectron spectroscopy, energy dispersive spectrometer and photoluminescence spectrum. The strongest emission intensity was observed with TiO2:Eu0.2 hollow spheres and TiO2:Eu0.2 hollow spheres calcining at 550^oC. Moreover, the strongest excitation of TiO2:Eu0.2 hollow spheres transferred from 400 to 500^oC and the effective nonradiative energy transfer from the TiO2 hollow spheres host matrix to Eu^3^+ ions crystal field states was realized due to changes of crystalline field in the environment around Eu^3^+ ions occupying Ti^4^+ site...

2010-01-01

278

Stresses and interfacial structure in Au-Ni and Ag-Cu metallic multilayers  

Energy Technology Data Exchange (ETDEWEB)

Metallic multilayers offer a fantastic playground to investigate elastic stresses in films of nanometer thickness. We will present and discuss a few examples from our recent work on Au-Ni and Ag-Cu systems where we combined plate bending measurements and electron or X-ray diffraction to investigate stress buildup and interfacial mixing. Comparing these two cases we discuss the results with respect to basic parameters like the misfits in lattice parameters and in elastic moduli, the mixing enthalpies and the surface energies.

2004-03-15

279

Out-of-pile simulation of mild TOPs; development of pin failure, material movement and relocation in bundle geometry  

International Nuclear Information System (INIS)

An experimental technique is described which allows for parametric investigations of transient behavior of mobile core materials in a fuel bundle geometry. For the out-of-pile simulation of energy releases resulting from mild TOP- or LOF-accidents the exothermic reaction of an aluminium-oxide-thermite is used. Transient material relocation inside the test section is recorded by X-ray-cinematography. Results of some experiments recently performed close to conditions expected to be achieved during mild TOP-accidents are described in detail.

1979-08-23

280

Mineral analysis in experimental corneal scars. An EDAX study  

Energy Technology Data Exchange (ETDEWEB)

Central penetrating excisional wounds were made in the corneas of 12 rabbits and 10 trout. The scar tissue and the surrounding cornea were compared using a new method for assessing inorganic elements in the cornea: the scanning electron microscopy and energy dispersive analysis of x-ray (EDAX). Semiquantitative determination of inorganic elements within the range of atomic numbers 9-93 in the periodic system was performed, comparing the relative concentration of those elements in the scar tissue to the surrounding cornea. Results showed that calcium was the only element higher in the healing wound than in the surrounding cornea.

1988-01-01

281

Influence of changes in the composition of Kh18N10T steel on the results of measurement of its thickness by the radiometric method  

International Nuclear Information System (INIS)

The additional error in measurement of the thickness of Kh18N10T steel for possible changes in composition with an energy of the photons of ionizing radiation of 10-80 keV was evaluated. The desirability of use of a type REIS-I x-ray emitter in measurement of the thickness of steel up to 1 mm is shown. The instrument provides measurement of the thickness of steel in the 0.1-1.0 mm range with a reproducibility of the results with an error not exceeding 0.5-1.0%. The measurement error with corrugations characteristic of bellows does not exceed 5%.

282

High pressure study of AlP: Transformation to a metallic NiAs phase  

Science.gov (United States)

The crystal structure and optical reflectivity of AlP has been studied in a diamond anvil cell using energy dispersive x-ray diffraction to 43 GPa and micro-optical reflectance spectroscopy to 36 GPa. AlP undergoes a first order phase transformation from zincblende to a NiAs structure which exhibits metallic reflectivity in the near-infrared. The decrease in volume on transformation is 17%[plus minus]1%. The transformation is reversible but has large hysteresis. The equilibrium transformation pressure is 9.5[plus minus]5 GPa.

1994-12-01

283

High Exposure Facility Technical Description  

Energy Technology Data Exchange (ETDEWEB)

The High Exposure Facility is a collimated high-level gamma irradiator that is located in the basement of the 318 building. It was custom developed by PNNL back in 1982 to meet the needs for high range radiological instrument calibrations and dosimeter irradiations. At the time no commercially available product existed that could create exposure rates up to 20,000 R/h. This document is intended to pass on the design criteria that was employed to create this unique facility, while maintaining compliance with ANSI N543-1974, "General Safety Standard for Installations Using Non-Medical X-Ray and Sealed Gamma-Ray Sources, Energies up to 10 MeV."

2008-02-12

284

FCR (Fuji Computed Radiography) in neurosurgery  

Energy Technology Data Exchange (ETDEWEB)

As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness.

1988-08-01

285

FCR (Fuji Computed Radiography) in neurosurgery  

International Nuclear Information System (INIS)

As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness. (author).

1988-01-01

286

Elemental concentration analysis in some plant samples by EDXRF at Trabzon  

International Nuclear Information System (INIS)

The elemental analysis of some plant samples have been carried out in Trabzon region (Turkey) using energy-dispersive X-ray fluorescence (EDXRF) spectrometry. We have analyzed plant samples for nine stations using 1.85 GBq 55Fe radioactive sources. We have found that potassium and calcium within 0.3-1.4% and 0.3-2.8% were present in concentration in plants for every station, respectively. The concentration of Cl and Ti generally changed according to the plant species and the sampling station.

2006-12-01

287

Creation of an antiferromagnetic exchange spring  

Science.gov (United States)

We present evidence for the creation of an exchange spring in an antiferromagnet due to exchange coupling to a ferromagnet. X-ray magnetic linear dichroism spectroscopy on single crystal Co/NiO(001) shows that a partial domain wall is wound up at the surface of the antiferromagnet when the adjacent ferromagnet is rotated by a magnetic field. We determine the interface exchange stiffness and the antiferromagnetic domain wall energy from the field dependence of the direction of the antiferromagnetic axis, the antiferromagnetic pendant to a ferromagnetic hysteresis loop. The existence of a planar antiferromagnetic domain wall, proven by our measurement, is a key assumption of most exchange bias models.

2004-04-06

288

Measurement of the mean energy of the off-axis incident electron without the beam guide. Using a scintillating fiber beam-energy monitor for electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

In the case of total skin electron therapy without the beam guide, the electron beam is scattered just outside the gantry exit, dose uniformity in the field is broken, and dose is spread outside the light field. The aims of this study were to measure the mean energy of the off-axis incident electron beam without the beam guide and to establish a reference for the clinical situation. For the measurement, a 4 MeV electron beam was selected among several energies from the linear accelerator. A scintillating fiber beam energy monitor measured the mean energy of the incident electron beam. This energy monitor is a small, light-weight piece of equipment composed of a wedge absorber, scintillation fiber, and photodiode. We found the relationship ...

2002-06-01

289

Low energy focused ion beams  

Energy Technology Data Exchange (ETDEWEB)

The performance of the PSI/ETH focused ion beam (FIB) system has been improved to produce ion beams of very low energies down to 40 eV with a reasonable spot size of 1 {mu}m at 200 eV. (author) 2 figs., 1 ref.

1996-10-01

290

Study of osteoporosis using dual energy X-ray absorptiometry  

Energy Technology Data Exchange (ETDEWEB)

Dual energy X-ray absorptiometry (Hologic QDR-1000) was used to quantitatively analyze the diagnosis and prevention of osteoporosis. The peak bone mineral density (BMD) of the spine appeared in normal men in their twenties and in normal women in their thirties. There was acceleration of bone loss in the 50 to 60 year age bracket (premenopause and postmenopause) in normal women. On the contrary, the peak BMD of the femoral neck in normal men and women appeared in their twenties after which it decreased slightly with age. Comparison showed that the femoral neck BMD of normal women was lower than that of men throughout all ages. The fracture threshold, 0.756 g/cm[sup 2] for the spine, was obtained by scanning 73 females with spinal fractures, the mean BMDs for L2-L4 at the 90th percentile level were used as the fracture threshold. The fracture threshold of femoral neck fracture was the femoral proximal BMD of the 9th decile. Classification by the ...

1992-04-01

291

Stabilizing effect of the electron-beam self-fields on the phase-space trajectory in a self-amplified spontaneous emission free-electron laser operating in ultraviolet and x-ray spectral ranges  

International Nuclear Information System (INIS)

A detailed treatment is introduced to measure the dynamic stability of the relativistic electrons in a self-amplified spontaneous emission free-electron laser (FEL) system, which includes the numerical approach of the Kolmogorov entropy (entropy-like quantity), the general equations of motion for a charged particle and the method of monitoring the simulation accuracy. Numerical experiments reveal a new phenomenon that there exists the possibility of the transition from chaotic to non-chaotic phase-space trajectories of the strongly relativistic electrons due to the effect of their self-fields. The adiabatic magnetic field of a one-dimensional wiggler may have a slight influence on the electron transportation in the absence of the FEL fields, but substantially affects the dynamic stability of the electrons in the process of the FEL interaction. Moreover, the laser fields diminish the dynamic stability of the electrons as the FEL interaction grows exponentially.

2004-02-28

292

Somatic and genetic radiation exposure of the patient in digital subtraction angiography (DSA)  

International Nuclear Information System (INIS)

The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation doses absorbed within the critical organs - red bone marrow, lung, thyroid gland and female breast - and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. projection, the use of an abdominal compression device and careful caudal shielding of the field are advocated. (orig.).

1986-01-01

293

Radiation protection - an overview of the concept for radiation protection at work and the concept for environmental radiation protection  

International Nuclear Information System (INIS)

This book gives an overview of the entire field of radiation protection with the subject areas radioactivity, X-rays, UV radiation, laser beams and high-frequency electromagnetic fields. It deals graphically with the most important physical notions, the incidence, origin, properties and biological effects of types of radiation, administrative and practical protection measures and the code of rules governing them. Apart from fundamentals of radiation protection the emphasis on the following: natural radiation exposure, radiation exposure to radon, disaster relief plans in the environment of nuclear plant, the precautionary radiation protection system evolved after Chernobyl, radiation exposure through UV radiation devices, radio, RF communication, radar, microwave ovens and high-voltage transmission lines as well as computer work-places. (orig.).

1993-01-01

294

Measurement of the bead profile and microstructural characterization of a CO2 laser welded AISI 904 L super austenitic stainless steel  

British Library Electronic Table of Contents (United Kingdom)

Laser welding of AISI 904 L super austenitic stainless steel using a diffusion cooled slab 3.5kW CO2 laser and employing two different shielding gases, namely argon and helium, was carried out. The laser weld bead profile depends on various parameters such as beam power (BP), travel speed (TS) and focal position (FP) of the laser spot. These parameters have to be selected suitably to obtain the desirable output. The cross sectioned area of the bead profiles measured using an optical microscope to determine the bead width and depth of penetration. X-ray diffraction used for phase identification confirmed that the weld structure was fully austenitic and dendritic. Hardness was observed to increase in the weld bead with respect to the parent metal and it was related to the microstructural ref...

2010-01-01

295

Determining concentration distribution of admixture from count ratemeter response in continuous analyses  

International Nuclear Information System (INIS)

A comparison is made of the response of a count ratemeter and a pulse counter using the mathematical tool of the Z transform. Transform Z is used for the solution of the convolution integral interpreting the analog output of the count ratemeter used for recording characteristic radiation, excited in the moving beam. The comparison of count rates obtained by the count ratemeter during continuous analysis and the pulse counter during discontinuous measurement gave the transfer function of the count ratemeter in the actual range of count rate. Also discussed is the use of the transfer function for localizing concentration changes in the sample. The use of the described method is demonstrated on the determination of the tin content in tungsten using continuous radionuclide X-ray fluorescence analysis. (B.S.).

1983-01-01

296

Constitutional examinations in the system Fe-Al-Zr; Konstitutionsuntersuchungen im System Fe-Al-Zr  

Energy Technology Data Exchange (ETDEWEB)

Two isothermal sections were prepared at 1000 and 1150 C showing the low-Zr phases of the system Fe-Al-Zr. The phase equilibria were determined by means of X-ray powder diffractometry and electron beam microanalysis. For initial characterisation of mechanical properties, hardness values are determined and added to the tabulated data. (orig./MM) [German] Es werden am Fe-Al-Zr-System zwei isotherme Schnitte durch den zirkoniumarmen Teil des Systems bei 1000 und 1150 C erstellt. Die auftretenden Phasengleichgewichte werden mit Hilfe der Roentgenpulverdiffraktometrie und Elektronenstrahlmikroanalyse aufgeklaert. Zusaetzlich werden zur ersten Charakterisierung der mechanischen Eigenschaften Haertewerte bestimmt.

1999-07-01

299

Spin evolution in wind-fed X-ray binaries  

International Nuclear Information System (INIS)

Global angular momentum balance suggests that the neutron stars in Be/X-ray binaries are not spinning in equilibrium. This requires an X-ray lifetime ''approx <'' 10"5 yr, and suggests that there are many 'dead' Be/X-ray binaries in the Galaxy. Some of these may be turned up as millisecond radio pulsars with Be star companions. (author).

305

Radionuclide X-ray fluorescence analysis. 3: Examples of application in practice  

Science.gov (United States)

Examples are given of the applicability and importance of radionuclide fluorescence analysis as a

1973-01-01

306

Radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Slovak 1973. 164 p. Czechoslovakia Havranek, E. Bumbalova, A. Svitel,

1973-01-01

307

Possibilities of rayleigh-taylor instability measurement by X-ray phase imaging  

International Nuclear Information System (INIS)

X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging

308

NONDESTRUCTIVE DETERMINATION OF AIRBORNE LEAD ...  

Science.gov (United States)

... NONDESTRUCTIVE DETERMINATION OF AIRBORNE LEAD PARTICULATES BY THE RADIONUCLIDE X-RAY FLUORESCENCE ANALYSIS. ...

310

Investigation of morphology and chemical composition of self-organized semiconductor quantum dots and wires by X-ray scattering  

International Nuclear Information System (INIS)

X-ray scattering methods suitable for the investigation of the morphology and chemical composition of self-organized quantum dots and quantum wires are reviewed. Their application is demonstrated in experimental examples showing that a combination of small angle X-ray scattering with high-resolution X-ray diffraction can reveal both the shape and the chemical composition of the self-organized objects. (author)

2001-09-23

311

Ectopic Ureter  

Science.gov (United States)

... such as renal flow scan or a formal kidney X-ray, called an intravenous pyelogram ( IVP ), may help ...

314

Report of the IPSM working party on low- and medium-energy x-ray dosimetry  

Energy Technology Data Exchange (ETDEWEB)

New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).

1991-08-01

315

Report of the IPSM working party on low- and medium-energy x-ray dosimetry  

International Nuclear Information System (INIS)

New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).

1991-01-01

316

Diffraction applications using the energy dispersive beamline X6A at the National Synchrotron Light Source  

Energy Technology Data Exchange (ETDEWEB)

The energy dispersive beamline X6A at the National Synchrotron Light Source employs a curved crystal monochromator (polychromator) which focuses a range ([similar to]1 keV) of x-ray energies into a narrow (100--120 [mu]m) line image. Although this beamline was constructed primarily for time-dependent EXAFS experiments, we have begun to explore the use of this instrument for energy dispersive diffraction experiments with different types of sample including macromolecular crystals. The tunability ([ital E]=6.5 to 21 keV) and flexibility ([Delta][ital E]=100--1000 eV) of the instrument makes the beamline ideal as a test bed for the application of polychromatic single-crystal diffraction techniques to different chemical or biological materials.

1995-02-01

317

The effect of a metal hip prosthesis on the radiation dose in therapeutic photon beam irradiations  

International Nuclear Information System (INIS)

Prostate and cervical cancer patients are often treated with external X-ray beams of bi-lateral incidence. Such treatment may incur some dose effect that cannot be predicted precisely in commercial treatment planning systems (TPS) for patients having undergone total hip replacement. This study performs a Monte Carlo (MC) simulation and an analytical calculation (convolution superposition algorithm which is implemented in ADAC TPS) of a 6 MV, 5x5 cm"2 X-ray beam incident into water with the existence of hip prosthesis, e.g. Ti6Al4V and CoCrMo alloy. The results indicate that ADAC TPS cannot precisely account for the scatter and backscatter radiation that a metal hip prosthesis causes. For percent depth dose (PDD) curves, the maximum underdosage of ADAC TPS up to 5 mm above the interface between dense material and water is 5%, 20% and 27% for PDD_B_o_n_e, PDD_T_i and PDD_C_o, respectively. The dose ...

2002-07-01

318

Are Optically-Selected Quasars Universally X-Ray Luminous? X-Ray/UV Relations in Sloan Digital Sky Survey Quasars  

CERN Document Server

We analyze archived Chandra and XMM-Newton X-ray observations of 536 Sloan Digital Sky Survey (SDSS) Data Release 5 (DR5) quasars (QSOs) at 1.7 <= z <= 2.7 in order to characterize the relative UV and X-ray spectral properties of QSOs that do not have broad UV absorption lines (BALs). We constrain the fraction of X-ray weak, non-BAL QSOs and find that such objects are rare; for example, sources underluminous by a factor of 10 comprise $\\la$2% of optically-selected SDSS QSOs. X-ray luminosities vary with respect to UV emission by a factor of $\\la$2 over several years for most sources. UV continuum reddening and the presence of narrow-line absorbing systems are not strongly associated with X-ray weakness in our sample. X-ray brightness is significantly correlated with UV emission line properties, so that relatively X-ray weak, non-BAL ...

2008-01-01

319

Scatter measurements for optical cone-beam computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Both x-ray and optical cone-beam CT (CBCT) scanners are limited by scattered photons that contaminate the primary images. Transparent radiochromic gels and plastics are anticipated to produce less scattering than polymerization gels and hence result in reconstructed dose distributions with greater contrast and dynamic range. Four methods of scatter measurement were investigated to quantify scatter fractions using an in-house optical CBCT scanner. The methods consisted of generating either 'coin' shadows or primary beamlets in transmission images. The four methods generated similar results of 10% scatter fractions in gel transmission images for this particular scanner configuration with both leuco crystal violet and carbon black micelle gels. The scatter contributions were distributed as 5% from micelle gel, 2% from Teflon wall, 2% from refractive index matching liquid and 1% other sources. Applying a uniform background ...

2009-05-01

320

Properties of ZnO thin films prepared by radio-frequency plasma beam assisted laser ablation  

International Nuclear Information System (INIS)

Zinc oxide thin films were obtained by laser ablation of a Zn target in oxygen reactive atmosphere, the oxygen being supplied either by a standard gas inlet valve or from a radio-frequency (rf) oxygen plasma. Pt-coated silicon and MgO were used as substrates. The influence of the deposition parameters as laser wavelength (266, 355, 1064 nm), laser fluence (1.5-20 J/cm2) and oxygen pressure (1-60 Pa) was studied. The influence of the rf plasma beam addition on the morphological proprieties of zinc oxide films was particularly investigated, simultaneously with several configurations of the direction of the ablation plasma, the rf plasma beam and the substrate. The obtained films, with thicknesses in the range of 50 nm to 1 ?m have been characterized by atomic force microscopy (AFM), X-ray diffraction (XRD), transmission electron microscopy (TEM).

2005-07-15

321

Evaluation of the increase of superficial dose due to thermoplastic immobilizing in radiotherapy; Avaliacao dos efeitos de superficializacao de dose por imobilizadores termoplasticos em radioterapia  

Energy Technology Data Exchange (ETDEWEB)

Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin dose distribution, clinical ...

2010-07-01

322

Evaluation of the increase of superficial dose due to thermoplastic immobilizing in radiotherapy  

International Nuclear Information System (INIS)

Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin dose distribution, clinical ...

2010-08-18

323

Tribological behavior of duplex coating improved by ion implantation  

Energy Technology Data Exchange (ETDEWEB)

In the present paper the tribological behavior of the coatings are discussed. Duplex coatings were applied on cold working steel 100Cr6. Samples were plasma nitrided at different thickness of plasma surface layers. TiN was deposited with a classic BALZERS PVD equipment and subsequent ion implantation. Ion implantation was provided with N{sup 5+} ions. The other samples were produced with IBAD technology in DANFYSIK chamber. Wear resistance and exchanges of friction coefficient were measured with on-line test using special designed tribology equipment. Following the tests, the wear zone morphology and characteristics of surface layer structure as well as important properties were investigated by scanning electron microscopy (SEM) and X-ray diffraction analysis (XRD). Scratch adhesion testing was performed using commercially available equipment. Energy dispersive X-ray analysis (EDAX) of the wear-scars on pins provided ...

2004-07-01

324

Time-Resolved Aerosol Collector for CCSEM/EDX Single Particle Analysis  

Energy Technology Data Exchange (ETDEWEB)

An automated Time Resolved Aerosol Collector (TRAC) has been developed for sequential sampling of field-collected aerosols for laboratory-based Computer Controlled Scanning Electron Microscopy/Energy Dispersed X-ray (CCSEM/EDX) single particle analysis. The collector is optimized for use of grid-supported 20 nm carbon films as deposition substrates. The carbon films have low enough X-ray background to permit EDX analysis down to 0.1-0.2 ?m particles, including detection of low-Z elements: C, N, & O. The TRAC provides unattended sampling onto a set of 151 individual grids, at sequential time intervals as short as 1 min. After collection, the samples are sealed and refrigerated pending analysis. The utility of the TRAC-CCSEM/EDX approach is exemplified using the aerosol samples collected during the Texas 2000 Air Quality Studies (Aug. 15 ? Sept. 15, 2000). We are able to quantitatively follow the time evolution in the ...

2003-01-02

325

Stoichiometry controlled conversion efficiency in nanostructured heterojunction solar cell of CdS/CuInSXSe2-X grown by chemical ion exchange method at room temperature  

British Library Electronic Table of Contents (United Kingdom)

Here in the present paper, we report on growth of stoichiometric and nonstoichiometric nanostructured heterojunction solar cell of CdS/CuInSXSe2-X varying X from 0 to 2 in the interval of 0.5 using cost effective, simple, chemical ion exchange method at room temperature on ITO glass substrate. The as-grown varying composition solar cells annealed at 200degreeC in air and characterized for structural, compositional, optical and illumination studies. The X-ray diffraction pattern obtained from CdS/CuInSXSe2-X solar cell confirms the formation of CuInSe2, CuInS0.5Se1.5, CuInS1Se1, CuInS1.5Se0.5 and CuInS2 phases having tetragonal structure with varying crystallite size from 19, 19.37, 28, 33 and 20nm respectively. The energy dispersive X-ray analysis (EDAX) confirms the expected elemental com...

2011-01-01

326

Sampling and analytical methodologies for energy dispersive X-ray fluorescence analysis of airborne particulate matter  

International Nuclear Information System (INIS)

The present document represents an attempt to summarize the most important features of the different forms of ED-XFR as applied to the analysis of airborne particulate matter. It is intended to serve as a set of guidelines for use by participants in the IAEA's own programmes, and other scientists, who are not yet fully experienced in the application of ED-XRF to airborne particulate samples, and who wish either to make a start on using this technique or to improve their existing procedures. The methodologies for sampling described in this document are of rather general applicability. Emphasis is also placed on the sources of errors affecting the sampling of airborne particulate matter. The analytical part of the document describes the different forms of ED-XRF and their potential applications. Spectrum evaluation, a key step in X-ray spectrometry, is covered in depth, including discussion on several calibration and peak fitting techniques and computer programs ...

1986-06-25

327

Preparation of Nanocomposite GDC/LSCF Cathode Material for IT-SOFC by Induction Plasma Spraying  

British Library Electronic Table of Contents (United Kingdom)

Homogeneous mixtures of Ce0.8Gd0.2O1.9 (GDC) and La0.6Sr0.4Co0.2Fe0.8O3 (LSCF) nanopowders were successfully synthesized using induction plasma by axial injection of a solution. The resulting nanocomposite powders consisted of two kinds of nanopowders with different mass ratio of GDC/LSCF, such as 3/7 and 6/4. The morphological features, crystallinity, and the phases of the synthesized powders were characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), local energy-dispersive x-ray spectroscopy (EDS) analysis, and x-ray diffraction (XRD). The nanopowders are almost globular in shape with a diameter smaller than 100?nm and their BET specific areas are around 20?m2?g?1. The GDC and LSCF phases are well distributed in the nanopowders. In addition, suspens...

2011-01-01

328

Preparation and characterization of iron oxide thin films by spray pyrolysis using methanolic and ethanolic solutions  

International Nuclear Information System (INIS)

Iron oxide thin films have been obtained by spray pyrolysis using 100% methanolic and ethanolic solutions of iron tri-chloride. The films were deposited onto ITO-coated glass substrates. The preparative conditions have been optimized to obtain compact, pin-hole-free and smooth thin films which are adherent to the substrate. The structural, morphological and compositional characterizations have been carried out by X-ray diffraction, scanning electron microscopy and energy dispersive X-ray analysis. The films deposited using ethanolic solution results into pure hematite; #alpha#-Fe_2O_3 thin films, however, films deposited using methanolic solution consists of hematite and maghemite-c phases of iron oxide. The films are nanocrystalline with particle size of 30-40 nm. The optical absorbance of the film was of the order of 10"5 cm"-"1. The optical band gap of films was found to be 2.26 and 2.20 eV for the films deposited using ...

2006-01-15

329

Phosphate/UO{sub 2} interaction during in vitro dissolution of inhalable particles in a medium simulating the phagolysosomal compartment  

Energy Technology Data Exchange (ETDEWEB)

Qualitative and quantitative methods have been developed to relate phosphate/UO{sub 2} interactions and U dissolution, in vitro, in a medium containing 0 or 10 mM phosphate concentrations at pH 5. This was performed by Energy Dispersive X ray Spectrometry (EDS) at 200 kV on entire particles and by fluorimetric measurement. The U dissolution rate was larger in a medium without phosphate than in a medium containing 10 mM phosphate. During the first day, the initial U dissolution involved 80.55% and 91.13% of the powder in media with and without phosphate respectively. From 5 to 15 d after beginning the assay, the dissolution half-times were longer than 92 d and 22 d for media with and without phosphate. EDS analyses have shown a constant P/U X ray intensity ratio for reference U{sub 2}O(PO{sub 4}){sub 2} for the same range of particle diameter. A gradual increase of this ratio was ...

1998-07-01

330

Microstructural transformations and kinetics of high-temperature heterogeneous gasless reactions by high-speed x-ray phase-contrast imaging  

Science.gov (United States)

Heterogeneous gasless reactive systems, including high-energy density metal-nonmetal compositions, have seen increasing study due to their various applications. However, owing to their high reaction temperature, short reaction time, and small scale of heterogeneity, investigation of their reaction mechanisms and kinetics is very difficult. In this study, microstructural changes and the kinetics of product layer growth in the W-Si system was investigated using a high-speed x-ray phase-contrast imaging technique. Using the Advanced Photon Source of Argonne National Laboratory, this method allowed direct imaging of irreversible reactions in the W-Si reactive system at frame rates up to 36 000 frames per second with 4 {mu}s exposure and spatial resolution of 10 {mu}m. Details of the Si melt and reactions between W and Si, that are unable to be viewed with visible-light imaging, were revealed. These include processes such as the initiation of ...

2009-12-01

331

Microstructural transformations and kinetics of high-temperature heterogeneous gasless reactions by high-speed x-ray phase-contrast imaging  

International Nuclear Information System (INIS)

Heterogeneous gasless reactive systems, including high-energy density metal-nonmetal compositions, have seen increasing study due to their various applications. However, owing to their high reaction temperature, short reaction time, and small scale of heterogeneity, investigation of their reaction mechanisms and kinetics is very difficult. In this study, microstructural changes and the kinetics of product layer growth in the W-Si system was investigated using a high-speed x-ray phase-contrast imaging technique. Using the Advanced Photon Source of Argonne National Laboratory, this method allowed direct imaging of irreversible reactions in the W-Si reactive system at frame rates up to 36 000 frames per second with 4 #mu#s exposure and spatial resolution of 10 #mu#m. Details of the Si melt and reactions between W and Si, that are unable to be viewed with visible-light imaging, were revealed. These include processes such as the initiation of ...

2009-12-01

332

Limits on the Diffuse Radio and Hard X-ray Emission of Abell 2199  

CERN Document Server

The Westerbork Northern Sky Survey (WENSS) and the NRAO/VLA Sky Survey (NVSS) were used to determine an upper limit to the diffuse radio flux from the nearby cluster Abell 2199. For the entire cluster, this limit is <3.25 Jy at 327 MHz from WENSS; for the inner 15' radius, the limit is <168 mJy at 1.4 GHz. These limits are used to constrain the cluster magnetic field by requiring that the radio flux be consistent with the hard X-ray (HXR) flux observed by BeppoSAX, assuming that the observed HXR excess is due to inverse Compton (IC) scattering of cosmic microwave background photons by relativistic electrons in the intracluster gas. We find that the magnetic field must be very weak (<0.073 uG) in order to avoid producing an observable radio halo. We also consider the possibility that the HXR excess is due to nonthermal bremsstrahlung (NTB) by a population of suprathermal electrons which are being accelerated to higher energies. We find ...

1999-01-01

333

In-situ X-ray diffraction approach to surface film growth kinetics  

Science.gov (United States)

A knowledge of surface film growth kinetics can be quite useful in the production of materials for uses ranging from protective coatings to microelectronic devices. A technique for determining the kinetics of film growth is presented which should prove to be a valuable alternative to the array of spectroscopies (AES, RBS, etc.) currently favored for these measurements. Some of the virtues of this X-ray diffraction approach are its non-destructive nature, thickness resolution better than 50 {angstrom} and conventional equipment requirements. Results obtained for the growth of Pd{sub 2}Si films during thermal annealing of Pd coatings on Si, indicate parabolic growth over a temperature range of 160-222 C. The rate constant was found to be k{prime} = 7 {times} 10{sup {minus}4} exp ({minus}1.06 eV/kT) cm{sup 2}/sec, where (film thickness){sup 2} = k{prime} x time. This activation energy is in agreement with results obtained by other techniques. A ...

334

Fuji computed radiography (FCR) for the diagnosis of spinal disorders  

International Nuclear Information System (INIS)

Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the cervicothoracic region, where it is usually difficult to obtain clear cervicothoracic films in conventional radiography. We can obtain ...

1987-01-01

335

Determination of small amounts of elements by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The determination of small amounts of elements by radionuclide X-ray fluorescence analysis is described. Samples containing 5x10"-"4 to 5x10"-"6 g of elements were fixed on a suitable carrier. For a coaxial configuration a low-energy source of the #gamma#/X type was used, namely an annular "2"4"1Am/Ag source with an activity of 7.4x10"8 s"-"1 (20 mCi), and for a configuration with side reflection source of the #beta#/X type was used, namely "1"4"7Pm/Sm with the activity of Pm(OH)_3 approximately 3.7x1O"1"0 s"-"1 (1 Ci). Cs, Ba, La, Pr, Nd, and Ag were determined by means of the Ksub(#alpha#) line and Hg, W, Er, and Pr by means of the Lsub(#alpha#) line. For all elements studied a detection limit of the order of 10"-"7 g was achieved. (author).

1975-01-01

336

Characterization of projected DWPF glasses heat treated to simulate canister centerline cooling  

Energy Technology Data Exchange (ETDEWEB)

Liquid high-level nuclear waste will be immobilized at the Savannah River Site (SRS) by vitrification in borosilicate glass. The glass will be produced and poured into stainless steel canisters in the Defense Waste Processing Facility (DWPF). Eventually these canistered waste forms will be sent to a geologic repository for final disposal. In order to assure acceptability by the repository, the Department of Energy has defined requirements which DWPF canistered waste forms must meet. These requirements are the Waste Acceptance Preliminary Specifications (WAPS). The WAPS require DWPF to identify the crystalline phases expected to be present in the final glass product. Knowledge of the thermal history of the borosilicate glass during filling and cooldown of the canister is necessary to determine the amount and type of crystalline phases present in the final glass product. Glass samples of seven projected DWPF compositions were cooled following the same temperature ...

1992-05-01

337

Characterization and gas-sensing behavior of an iron oxide thin film prepared by atomic layer deposition  

International Nuclear Information System (INIS)

In this work we investigate an iron oxide thin film grown with atomic layer deposition for a gas sensor application. The objective is to characterize the structural, chemical, and electrical properties of the film, and to demonstrate its gas-sensitivity. The obtained scanning electron microscopy and atomic force microscopy results indicate that the film has a granular structure and that it has grown mainly on the glass substrate leaving the platinum electrodes uncovered. X-ray diffraction results show that iron oxide is in the #alpha#-Fe_2O_3 (hematite) phase. X-ray photoelectron spectra recorded at elevated temperature imply that the surface iron is mainly in the Fe"3"+ state and that oxygen has two chemical states: one corresponding to the lattice oxygen and the other to adsorbed oxygen species. Electric conductivity has an activation energy of 0.3-0.5 eV and almost Ohmic current-voltage dependency. When exposed to O_2 ...

2008-07-31

338

Radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The author's achievements in the title field are summarized and discussed. The following topics are dealt with: (i) principles of radionuclide X-ray fluorescence analysis; (ii) mathematical methods in X-ray fluorescence analysis; (iii) Ross differential filters; (iv) application of radionuclide X-ray fluorescence analysis in the coal industry (with emphasis on the determination of the ash content, sulfur content, and arsenic content of coal); and (v) evaluation of the X-ray fluorescence analyzer from the radiological safety point of view. (P.A.).

1994-01-01

339

Future of X-ray phase imaging in medical imaging technology  

International Nuclear Information System (INIS)

Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)

2007-04-01

340

An Apparent Hard X-ray Decline of CH Cygni  

CERN Document Server

CH Cygni is a symbiotic star consisting of an M giant and an accreting white dwarf, which is known to be a highly variable X-ray source with a complex, two-component, spectra. Here we report on two Suzaku observations of CH Cyg, taken in 2006 January and May, during which the system was seen to be in a soft X-ray bright, hard X-ray faint state. Based on the extraordinary strength of the 6.4 keV fluorescent Fe K-alpha line, we show that the hard X-rays observed with Suzaku are dominated by scattering.

2006-01-01

341

Electronic structure of face-centred cubic MoO_2: A comparative study by the full potential linearized augmented plane wave method, X-ray emission spectroscopy and X-ray photoelectron spectroscopy  

International Nuclear Information System (INIS)

X-ray emission spectroscopy (XES) and X-ray photoelectron spectroscopy (XPS) methods were employed in the present paper to investigate the electronic structure of face-centred cubic (fcc) molybdenum dioxide, fcc-MoO_2. For the mentioned compound, the XES O K#alpha# and Mo L#beta#_2_,_1_5 bands reflecting the valence O p- and Mo s,d-like states, respectively, were derived and compared on a common energy scale with the XPS valence-band spectrum. For comparison, the similar experimental studies of the electronic structure were made for a usual orthorhombic form of molybdenum trioxide, MoO_3. Band-structure calculations of fcc-MoO_2 were made using the full potential linearized augmented plane wave (FP-LAPW) method. A rather good agreement of the experimental XES and XPS results and the theoretical FP-LAPW data for the electronic properties of fcc-MoO_2 has been achieved in the present paper. A new near-Fermi sub-band was ...

2008-07-14

342

Population doses from beam-therapy in Japan, 1978, 3  

International Nuclear Information System (INIS)

As a series of estimations of population doses and of risk estimates from medical exposures in Japan, the malignancy significant dose (MSD) and the fatal malignant risk from beam therapy were estimated based on a nationwide survey of radiotherapeutic treatments, using a malignancy significant factor and a weighting factor determined from the data on the cancer mortality among the atomic bomb survivors in Nagasaki. The effective dose was defined as a sum of the product of the weighting factor and the organ or tissue doses with respect to the malignant diseases. The organ or tissue doses were determined with ionization chambers placed at the positions of their center in a MixDp-phantom simulated lung tissues by a block of cork, using a telecobalt unit, a conventional X-ray unit and a medical linear accelerator. The organ or tissue doses were categorized into three dose components; namely 1) dose from useful beams; 2) ...

1981-01-01

343

Analysis of beam emittance in FEL (Free Electron Laser)  

International Nuclear Information System (INIS)

To achieve high efficiency for the conversion of electron kinetic energy in an electron beam to electromagnetic energy in a Free Electron Laser (FEL), it is important to improve the beam quality. And hence, it is necessary to study and minimize the emittance growth of the beam. According to the requirements for the beam quality in an FEL, the author analyzed the emittance growth caused by the jump of the electric field in an accelerator, energy increase, wakefield in a waveguide, space charge effect and distribution of particles in a beam as well as the wakefield in a deflect system etc. The author also estimated the emittance change caused by the variation of the microwave field from the gun to the first accelerator for such case.

344

Target Diagnostic Instrument-Based Controls Framework for the National Ignition Facility  

Energy Technology Data Exchange (ETDEWEB)

NIF target diagnostics are being developed to observe and measure the extreme physics of targets irradiated by the 192-beam laser. The response time of target materials can be on the order of 100ps--the time it takes light to travel 3 cm--temperatures more than 100 times hotter than the surface of the sun, and pressures that exceed 109 atmospheres. Optical and x-ray diagnostics were developed and fielded to observe and record the results of the first 4-beam experiments at NIF. Hard and soft x-ray spectra were measured, and time-integrated and gated x-ray images of hydrodynamics experiments were recorded. Optical diagnostics recorded backscatter from the target, and VISAR laser velocimetry measurements were taken of laser-shocked target surfaces. Additional diagnostics are being developed and commissioned to observe and diagnose ignition implosions, including various neutron and ...

2007-05-07

345

Upper Limits from HESS Observations of AGN in 2005-2007  

CERN Document Server

Very high energy (VHE; >100 GeV) observations of a sample of selected active galactic nuclei (AGN) were performed between January 2005 and April 2007 with the High Energy Stereoscopic System (HESS), an array of imaging atmospheric-Cherenkov telescopes. Significant detections are reported elsewhere for many of these objects. Here, integral flux upper limits for twelve candidate very high energy (VHE; >100 GeV) gamma-ray emitters are presented. In addition, results from HESS observations of four known VHE-bright AGN are given although no significant signal is measured. For three of these AGN (1ES 1101-232, 1ES 1218+304, and Mkn 501) simultaneous data were taken with the Suzaku X-ray satellite.

2007-01-01

346

Studies of technetium chemistry. Pt. 13: The relationship between solvation free energies and brain uptakes of "9"9Tc"m complexes  

International Nuclear Information System (INIS)

Based on the X-ray crystallographic data of Tc-complexes for brain imaging agents, geometry optimizations in vacuo of TcO-BAT, TcO-MAMA, TcO-L, L-ECD, TcN-BAT and TcN-L, L-ECD complexes are performed with Hartree-Fock method and LANL 2 DZ basis set of G98W program. Then solvation free energy for each Tc-complex mentioned above in water is calculated by polarizable continuum method (PCM) including models of CPCM and IEFPCM. The results show that solvation free energy of Tc-complex is not only an indicator of lipophilicity but also one of the important factors that influence the brain uptake

2002-02-01

347

Determination of Proper Peaking Time for Ultra Lege detector at Medium Energies  

International Nuclear Information System (INIS)

Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the optimum peaking time for particular detector systems is important. For this purpose, pure Se and Zn elements were excited by 59.5 keV ?-rays from a 50 mCi 241Am annular radioactive source in this study. The characteristic x-rays emitted from pure Se and Zn elements were detected by using an ultra low energy Ge (Ultra-LEGe) detector connecting Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by HM 203-7 oscilloscope connecting amplifier. The proper peaking time for ultra low energy germanium detector (Ultra-LEGe) is determined about 4 ?s.

2008-08-25

348

LIONEL V. BALDWIN  

Science.gov (United States)

Aug. 24, 1965. L. V. BALDWIN ETAL. 3202915. PARTICLE BEAM MEASUREMENT APPARATUS USING BEAM KINETIC. ENERGY TO CHANGE TIIE HEAT SENSITIVE RESISTANCE OF ...

349

X-ray and vibrational spectroscopy of manganese complexes relevant to the oxygen-evolving complex of photosynthesis  

Energy Technology Data Exchange (ETDEWEB)

Manganese model complexes, relevant to the oxygen-evolving complex (OEC) in photosynthesis, were studied with Mn K-edge X-ray absorption near-edge spectroscopy (XANES), Mn Kb X-ray emission spectroscopy (XES), and vibrational spectroscopy. A more detailed understanding was obtained of the influence of nuclearity, overall structure, oxidation state, and ligand environment of the Mn atoms on the spectra from these methods. This refined understanding is necessary for improving the interpretation of spectra of the OEC. Mn XANES and Kb XES were used to study a di-(mu)-oxo and a mono-(mu)-oxo di-nuclear Mn compound in the (III,III), (III,IV), and (IV,IV) oxidation states. XANES spectra show energy shifts of 0.8 - 2.2 eV for 1-electron oxidation-state changes and 0.4 - 1.8 eV for ligand-environment changes. The shifts observed for Mn XES spectra were approximately 0.21 eV for oxidation state-changes and only approximately 0.04 eV ...

2001-05-16

350

Nuclear radiation detectors on II-VI compounds  

International Nuclear Information System (INIS)

Nuclear radiation detectors in integral execution were produced by successive epitaxial growth from vapor phase of Zn Te and Cd Se thin layers onto scintillating Zn Se (Te) crystals. The irradiation of combined Zn Se (Te) - Zn Te - Cd Se detectors by Cu_K_a X-rays leads to the appearance of photoreceiver e.m.f., which tends to saturation with the increase of X-ray radiation dose reaching the value of 0.34-0.40 V at 200 R/min. The short circuit current dependence of irradiation dose power is linear. The matching factor for detectors with Zn Te-Cd Se photoreceivers with different doping levels is 0.68-0.92. The absolute monochromatic sensitivity is 0.32-0.35 m A/m W at a quantum efficiency 0.58-0.61 and a time constant 2 x 10"-"4 s. The calculated dose sensitivity for Zn Se(Te)-Zn Te-Cd Se combined detectors at the irradiation with X-rays having effective energy 8.86 keV gives the value 3.9 x 10"-"7 ...

1993-10-13

351

Single-pass high-gain free electron laser electron beam diagnostics  

International Nuclear Information System (INIS)

Consensus reached in the last few years that fourth generation light source will most likely be a X-ray or a UV coherent source based on single-pass high-gain free electron laser (FEL), such as Self Amplified Spontaneous Emission (SASE), or seeded high-gain harmonic-generation (HGHG) free electron lasers. High-gain (>10"7) required for single-pass FEL puts great constrain on the quality of electron beam, and demands detailed distribution information of electron beam in six-dimension. The typical accelerator system for single-pass FEL consists of a photocathode RF gun injection system, a linac and magnetic bunch compressors, and a long undulator. The major challenges in beam diagnostics for single-pass FEL are to characterize the pico-seconds high-brightness electron beam in six-dimension produced by photocathode RF gun injector, and improve the stability and reliability of the ...

2000-11-27

352

X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography  

International Nuclear Information System (INIS)

Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a ...

2002-03-01

353

Polymer-metal complex as gel electrolyte for quasi-solid-state dye-sensitized solar cells  

International Nuclear Information System (INIS)

A kind of polymer-metal complex gel electrolyte is successfully prepared and is used in dye-sensitized solar cells. Raman and X-ray photoelectron spectroscopy confirm the structure of this complex and is found that the metal ion reacts with nitrogen in the polymer. This novel electrolyte shows apparent diffusion coefficient of iodide of 8.37 x 10-7 cm2 s-1 and the energy conversion efficiency of 6.10% when the amount of ZnI2 is 0.04 M. By studying the dissociation active energy of the inorganic salt in electrolytes, we find that the metal salts can dissociate more easily after reacting with polymer and as a result can provide extra free iodide ion. The cell maintains ca. 93% of its initial efficiency after 20 d without further sealing, which shows good long-time stability.

2011-01-01

354

On plasma nitriding of steels  

Energy Technology Data Exchange (ETDEWEB)

With the aim of optimizing the nitriding process, experimental studies of the plasma nitriding of four selected steels were carried out, using a d.c. glow discharge. The process parameters were varied systematically. By means of transmission and scanning electron microscopy and X-ray diffraction, the microstructures, including the thicknesses of the compound zones and the diffusion zones of the nitrided steels, were obtained. Using cross-sectional samples and a micro-Vickers indenter, hardness depth profiles were also obtained. From the time and temperature dependences of the hardness profiles, effective diffusion constants and corresponding activation enthalpies were obtained. Furthermore, in an attempt to shed some light on the atomistic nitriding mechanisms, the glow discharges were studied by measuring energy spectra of the energetic ions hitting the cathode (the steel test specimens). It was shown that an increase of the mean ...

2000-02-01

355

Kinetics of pore coarsening in glassy carbon  

Energy Technology Data Exchange (ETDEWEB)

One third of the microstructure of glassy carbon (GC) consists of closed pores. Density measurements indicate that the total pore volume depends only on the heat treatment temperature and not on the heat treatment time, a characteristic of coarsening. The kinetics of coarsening of these pores on heat treatment has been investigated by analyzing the changes in specific surface area of the pores as determined by the small angle X-ray scattering (SAXS) technique. A part of the surface area change is due to thermal expansion induced microcracking. Both the superposition method after correcting the thermal expansion induced surface area change and the curve fitting method give an activation energy of 64 +/- 10 kcal/mole. This value is compared with the activation energies of various rate processes in graphite. A model of coarsening of the pores based on a vacancy migration mechanism is proposed.

1981-01-01

356

Identifying fade mechanisms in high-power lithium-ion cells.  

Energy Technology Data Exchange (ETDEWEB)

Hybrid electric vehicles (HEV) need long-lived high-power batteries as energy storage devices. Batteries based on lithium-ion technology can meet the high-power goals but have been unable to meet HEV calendar-life requirements. As part of the US Department of Energy's Advanced Technology Development (ATD) Program, diagnostic studies are being conducted on 18650-type lithium-ion cells that were subjected to accelerated aging tests at temperatures ranging from 40 to 70 C. This article summarizes data obtained by gas chromatography, liquid chromatography, electron microscopy, X-ray spectroscopy and electrochemical techniques, and identifies cell components that are responsible for the observed impedance rise and power fade.

2004-01-01

357

Electronics Personal Dosemeter (EPD-N) Test and Evaluation Report  

Energy Technology Data Exchange (ETDEWEB)

Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization then used at another site.

2003-04-08

358

Characterization of acid sites in pentasil zeolites by x-ray photolectron spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

The N{sub 1s} XPS band of pyridine chemisorbed on Al-ZSM-5 zeolite was found to be properly deconvoluted into three component peaks. In a previous contribution these three components were assigned to pyridine chemisorbed on two kinds of Bronsted acid sites and one Lewis acid site. This analysis is extended here to Fe-ZSM-5 and B-ZSM-5. Isomorphous substitution of Fe for Si or Al in the zeolite framework leads to a slight decrease in the binding energy of the N{sub 1s} Lewis component. In the case of B substitution a decrease in the binding energy of all three N{sub 1s} components is observed.

1990-11-01

359

Fluid flow visualization with neutron radiography. [Using collimated beam of neutrons  

Energy Technology Data Exchange (ETDEWEB)

A technique was developed that permits fluid flow to be visualized even where the flow is completely shrouded by metal. The technique employs real-time neutron radiography, which is similar to x-ray radiography except a collimated beam of neutrons is used. Various combinations of neutron-opaque tracer materials were tested with neutron-transparent fluid. Neutron opaque tracers, such as solid particles, fluid droplets, and streaklines were imaged through metal walls as they convected in neutron-transparent ambient fluid. Visualization of bubbles/voids were evaluated for possible future applications. Surface-flow patterns were also imaged by using neutron-opaque tufts. These techniques were evaluated for image contrast, resolution, and the ability to accurately track fluid flow fields. The techniques were also modeled to optimize contrast in various flow configurations. Imaging techniques such as real-time video, high speed video, and ...

1991-01-01

360

A Single-Shot Method for Measuring Femtosecond Bunch Length in Linac-Based Free-Electron Lasers  

International Nuclear Information System (INIS)

There is growing interest in the generation and characterization of femtosecond and subfemtosecond pulses from linac-based free-electron lasers (FELs). In this report, following the method of Ricci and Smith (Phys. Rev. ST Accel. Beams 3, 032801 (2000)), we investigate the measurement of the longitudinal bunch profile of an ultrashort electron bunch produced by these FELs. We show that this method can be applied in a straightforward manner at x-ray FEL facilities such as the Linac Coherent Light Source by slightly adjusting the second bunch compressor followed by running the bunch on an rf zero-crossing phase of the final linac. We find that the linac wakefield strongly perturbs the measurement, and through analysis show that it can be compensated in a simple way. We demonstrate the effectiveness of this method and wakefield compensation through numerical simulations, including effects of coherent synchrotron radiation and longitudinal space ...

2010-08-26

361

Proton beam monitoring and forming on the target of isotope complex at INR linac  

International Nuclear Information System (INIS)

Special beam extraction channel is used at INR linac for isotope production. It starts from 160 MeV measuring and matching area of accelerator. This choice of beam extraction enables to direct to the target of isotope complex a proton beam of wide energy range up to 160 MeV. It is important for production of different types of nuclides. The measuring results of proton beam behavior in this region are presented. Required beam forming in 160 MeV measuring and matching area of accelerator and in beam extraction channel is discussed.

2010-01-01

362

Determination of radiation exposure and significance of its influential factors for X-rayed children in the GDR  

International Nuclear Information System (INIS)

After having discussed the peculiarities of children in X-ray diagnosis the application of the effective as well as the mean equivalent doses as to the determination of the radiation exposure in children is represented. In using computerized tomograms to determine position and extent of an organ the exposure by repeated X-raying was calculated referring to the entrance dose. Entrance dose measurements for all types of X-ray examination in hospitals and ascertainments of the frequency of radiograms in 20 X-ray departments were used to determine per capita and collective doses, resp., in several age groups. Alltogether, the per capita dose of children in the GDR amounts to 30% of that of adults. Conclusions were drawn as to taking measures to further reduction of radiation exposure: (1) Technical measures, such as positioning of patients, shielding of organs, quality assurance; (2) elaboration of ...

1988-01-01

363

A comparison of patient doses in lumbar spine radiography from various X-ray units in Poland  

Energy Technology Data Exchange (ETDEWEB)

A number of diagnostic X-ray units in Poland were subjected to analysis. The air kerma on X-ray tables was measured for the X-ray parameters used routinely during lumbo-sacral spine radiography of standard adult patient. Measurements of air kerma were performed using TLD made of lithium-fluoride. The doses received by patients in different X-ray departments can differ more than two orders of magnitude (from 0.42 mGy up to 72.11 mGy), for the same X-ray examination. The dose can be significantly reduced if fluorescent screens made from components of rare earth are used. (author). 10 refs, 1 fig., 2 tabs.

1995-12-31

364

Photodetachment of negative ion beams in the presence of a background gas  

Energy Technology Data Exchange (ETDEWEB)

To suppress space charge blowup in an ion beam passing through a photoneutralizer, it is necessary to introduce some background gas. An analysis is presented of the neutralization of a high-energy, >200-keV negative deuterium ion beam, exposed to photodetachment while in the presence of deuterium. With a gas thickness of <0.01 Torr.cm, the neutral fraction in the output beam is found to be about the same as that gotten from the photoneutralizer operating in vacuum. Neutral atom beam injection for plasma heating is discussed.

1987-03-01

365

A new scheme of the longitudinal emittance measurement for negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

A new scheme of the longitudinal emittance measurement for high energy negative ion beam is proposed. The energy distribution of the detached electron from the negative ions by the photodetachment process, if the photon energy is almost equal to the electron binding energy of the negative ion (=electron affinity of the atom), reflects that of the original negative ions. Therefore, by introducing the photon in a short width comparing with the bunch width of the negative ion beam, the longitudinal energy distribution of each phase of the beam, that is the longitudinal emittance, can be measured. (author).

1995-08-01

366

Longitudinal emittance oscillation in a superconducting drift tube linac  

International Nuclear Information System (INIS)

In drift tube linacs a beam energy spread results form the finite beam size. Radial variation of the axial accelerating field induces a beam energy spread, which, in general, will accumulate as the beam passes through successive drift tubes. This paper shows that under some conditions of periodic transverse focusing and longitudinal phase focusing, the correlation between the longitudinal and transverse motion can be used to correct the energy spread. The process of achieving such a correction is first described in a simplified situation, and then demonstrated for a particular tuning using a ray-tracing program which models a low velocity and low charge state linac designed for radioactive ion beams.

1995-05-01

367

Biogenic iron oxyhydroxide formation at mid-ocean ridge hydrothermal vents: Juan de Fuca Ridge  

Energy Technology Data Exchange (ETDEWEB)

Here we examine Fe speciation within Fe-encrusted biofilms formed during 2-month seafloor incubations of sulfide mineral assemblages at the Main Endeavor Segment of the Juan de Fuca Ridge. The biofilms were distributed heterogeneously across the surface of the incubated sulfide and composed primarily of particles with a twisted stalk morphology resembling those produced by some aerobic Fe-oxidizing microorganisms. Our objectives were to determine the form of biofilm-associated Fe, and identify the sulfide minerals associated with microbial growth. We used micro-focused synchrotron-radiation X-ray fluorescence mapping (mu XRF), X-ray absorption spectroscopy (mu EXAFS), and X-ray diffraction (mu XRD) in conjunction with focused ion beam (FIB) sectioning, and highresolution transmission electron microscopy (HRTEM). The chemical and mineralogical composition of an Fe-encrusted biofilm was queried at ...

2008-05-22

368

X-ray dosimetry of TlGaSe_2 single crystals  

International Nuclear Information System (INIS)

TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. ...

369

Focused ion beam (FIB) milling of electrically insulating specimens using simultaneous primary electron and ion beam irradiation  

International Nuclear Information System (INIS)

There is currently great interest in combining focused ion beam (FIB) and scanning electron microscopy technologies for advanced studies of polymeric materials and biological microstructures, as well as for sophisticated nanoscale fabrication and prototyping. Irradiation of electrically insulating materials with a positive ion beam in high vacuum can lead to the accumulation of charge, causing deflection of the ion beam. The resultant image drift has significant consequences upon the accuracy and quality of FIB milling, imaging and chemical vapour deposition. A method is described for suppressing ion beam drift using a defocused, low-energy primary electron beam, leading to the derivation of a mathematical expression to correlate the ion and electron beam energies and currents with other parameters required for ...

2007-02-07

370

X-Ray Phase Imaging for Breast Cancer Detection  

Science.gov (United States)

... Accession Number : ADA535309. Title : X-Ray Phase Imaging for Breast Cancer Detection. Descriptive Note : Annual rept. 1 Sep 2009-31 Aug 2010 ...

2010-09-01

371

Tissue oxygenation in a murine SCC VII tumor after X-ray irradiation as determined by EPR spectroscopy  

UK PubMed Central (United Kingdom)

PurposeThe goal of this study was to clarify the dynamics of tumor oxygen (partial pressure of oxygen, pO2) in SCC VII murine tumors in mice after X-ray...Full Text Available

2008-03-01

372

Small-Angle X-ray Scattering of Reduced Ribonuclease A: Effects of Solution Conditions and Comparisons with a Computational Model of Unfolded Proteins  

UK PubMed Central (United Kingdom)

The disulfide-reduced form of bovine ribonuclease A (RNAse A), with the Cys thiols irreversibly blocked, was characterized by small-angle x-ray scattering (SAXS). To help resolve the conflicting...Full Text Available

2008-04-11

373

Radionuclide X-ray fluorescence analysis of waste water from the production of citric acid  

Energy Technology Data Exchange (ETDEWEB)

Radionuclide X-ray fluorescence analysis was used for the determination of iron, calcium, potassium, copper, manganese and zinc in waste water from the production process of citric acid.

1982-02-18

374

Radionuclide X-ray fluorescence analysis of waste water from the production of citric acid  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis was used for the determination of iron, calcium, potassium, copper, manganese and zinc in waste water from the production process of citric acid. (author).

1982-02-01

375

Radiation exposure due to X-rays of the hip joint in babies  

International Nuclear Information System (INIS)

Exact anatomic knowledge about the location of the gonads and the application of corresponding measures of radiation protection are the preconditions for an efficient reduction of the danger of a possible genetic damage as a result of radiation exposition during X-ray examination of the hip joint of newborns. (VJ).

376

Numerical optimization of spherical variable-line-spacing grating X-ray spectrometers  

UK PubMed Central (United Kingdom)

Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and...Full Text Available

2011-03-01

377

Noise Characterization of Polycrystalline Silicon Thin Film Transistors for X-ray Imagers Based on Active Pixel Architectures  

UK PubMed Central (United Kingdom)

An examination of the noise of polycrystalline silicon thin film transistors, in the context of flat panel x-ray imager development, is reported. The study was conducted in the spirit of exploring...Full Text Available

2008-01-01

378

Method of describing dose distributions in computer design of teleradiotherapy  

International Nuclear Information System (INIS)

Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.

379

Measurements of accurate x-ray scattering data of protein solutions using small stationary sample cells  

UK PubMed Central (United Kingdom)

In this paper, we report a method of precise in situ x-ray scattering measurements on protein solutions using small stationary sample cells. Although reduction in the radiation damage...Full Text Available

2009-01-01

380

Magnetic fields of x-ray pulsars  

Energy Technology Data Exchange (ETDEWEB)

An analytic model of magnetic torques applied to an accreting neutron star is employed to evaluate the magnetic dipole moments of x-ray pulsars. A new type of close binary system containing a neutron star is suggested.

1982-09-01

381

Experimental X-ray intensity ratio L#beta#/L#alpha#  

International Nuclear Information System (INIS)

Experimental, relative intensities for the components of L X-ray were collected from literature, and atomic-number dependency of L#beta#/L#alpha# has been found. (author).

1980-01-01

382

Contribution to the radionuclide x-ray fluorescence analysis of human blood and plasma  

International Nuclear Information System (INIS)

A photon-induced x-ray fluorescence method allowing the simultaneous determination of iron, copper, zinc, bromine and rubidium in human blood and blood plasma samples is described. The method is reliable and has a good sensitivity for a wide range of elements. (author).

1986-04-01

383

Complex Spatio-Spectral Structure of Diffuse X-Ray emission in the ...  

Science.gov (United States)

SN 1987A: Soft X-Ray Intensity Ratio. 2002-12 to 2000-12. 2005-7 to 2002-12. Contours: 2002-12. (0.5 2 keV). (0.5 2 keV). Contours: 2005-7 ...

384

Chemical effects on K x-ray intensity ratios in chromium compounds  

International Nuclear Information System (INIS)

K_#beta#/ K_#alpha# x-ray intensity ratio of chromium were measured in different chromium compounds. The results show the variation of the intensity ratio as a function of the chemical environment around the metal ion. (author)

2003-02-10

385

Characterization and catalytic oxidation activity of uranium-bismuth mixed oxides  

International Nuclear Information System (INIS)

Bi-U mixed oxides were synthesized by two methods and characterized by X-ray diffraction and X-ray photoelectron spectroscopy. The samples were tested for the catalytic oxidation of carbon monoxide by oxygen. A stepwise redox mechanism consistent with the kinetic results is proposed. (orig.).

386

Chandra Observations of Nuclear X-ray Emission from a Sample of Radio Sources  

CERN Document Server

We present the X-ray properties of a sample of 17 radio sources observed with the Chandra X-ray Observatory as part of a project aimed at studying the X-ray emission from their radio jets. In this paper, we concentrate on the X-ray properties of the unresolved cores. The sample includes 16 quasars (11 core-dominated and 5 lobe-dominated) in the redshift range z=0.30--1.96, and one low-power radio-galaxy at z=0.064. No diffuse X-ray emission is present around the cores of the quasars, except for the nearby low-power galaxy that has diffuse emission on a scale and with a luminosity consistent with other FRIs. No high-amplitude, short-term variability is detected within the relatively short Chandra exposures. However, 1510-089 shows low-amplitude flux changes with a timescale of $\\sim$25 minutes. The X-ray spectra of the quasar cores are generally well described ...

2003-01-01

387

APOD: 2002 July 11 - M51: X Rays from the Whirlpool  

Science.gov (United States)

picture will download the highest resolution version available. M51: X-Rays from the Whirlpool Credit: A. Wilson (UMD) et al., CXC, NASA Explanation: Fresh from yesterday's...

2011-10-07

388

A comparison of iterative algorithms and a mixed approach for in-line x-ray phase retrieval  

UK PubMed Central (United Kingdom)

Previous studies have shown that iterative in-line x-ray phase retrieval algorithms may have higher precision than direct retrieval algorithms. This communication compares three iterative phase...Full Text Available

2009-08-15

389

8. Application of radionuclide X-ray fluorescence analysis in other fields of science and technology  

International Nuclear Information System (INIS)

Certain applications are described of radionuclide X-ray fluorescence analysis in the ore dressing industry, in the manufacture of building materials, in metallurgy, pharmacy, in the chemical, photographic and paper industries, in space exploration, in archeology and for measuring the thicknesses of thin layers of coatings. (ES).

1983-12-01

390

Ion beam pulsing for time of flight (TOF) experiments  

Energy Technology Data Exchange (ETDEWEB)

The essential mechanical and electronic parts of a beam pulsing system are described, which reaches an energy resolution of ..delta..E/E=0.1%-0.4% in the energy range from 100 eV and 10 keV.

1985-01-01

391

Beam stabilization in SPring-8 linac for top-up injections into storage rings  

International Nuclear Information System (INIS)

The SPring-8 linac has been improved to realize stable top-up injection into the SPring-8 and the NewSUBARU storage rings. The beam energy instability of 0.02% rms in the long term was achieved by means of reducing RF variations, providing beam energy compensation, reinforcement of monitor systems and introduction of beam feedback controls: Variations in the RF power and phase have been reduced by improving the voltage regulation system for the klystron modulator, and by stabilizing the temperature drift of the atmosphere and cooling water in order to reduce the phase variation. A new synchronous oscillator synchronizes a beam trigger pulse and a 2856 MHz reference signal, reducing variation in the beam charge. A beam energy compression system (ECS) was installed to compensate for accidental ...

2006-03-01

392

The Structural and Optical Properties of GaAs1-xPx /GaAs  

International Nuclear Information System (INIS)

GaAs1-xPx p-n junction structures were grown on the epi-ready n-type GaAs(100) substrate by solid source MBE system for different phosphor compositions. To obtain the lattice-match sample structure was applied graded growth procedure. The structural and optical properties of the sample structures with different P concentration were investigated by using X-ray diffraction (XRD), spectroscopic ellipsometry (SE). In addition, The range of lattice parameters in the graded epilayer and phosphorous composition were determined from the HRXRD rocking curve simulation. We analyse dielectric function spectra of disordered GaAs1-xPx junction structures measured using spectroscopic ellipsometry at room temperature in the 0.6-4.7 eV photon energy region. The critical energy points such as band gap energy and spin-orbit-split energy of these structures were determined using SE data. It is ...

2008-08-25

394

Superconducting properties of metallic superlattices  

Energy Technology Data Exchange (ETDEWEB)

The preparation by sputtering of artificial metallic superlattices is described, as are the results of x-ray structural determinations. Tunneling and resistivity measurements on these materials are reported.

1987-01-01

395

Radionuclide X-ray fluorescence analysis using semiconductor detectors  

International Nuclear Information System (INIS)

Czech May 1979. p. 32-33. Czechoslovakia Benada, J. Spacek, B. Ustav

1979-05-01

396
397

Plasma diagnostics in the optical and X-ray regions on the plasma focus device PF-4 (TULIP)  

International Nuclear Information System (INIS)

... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,

2006-09-11

398

Microcomputers in radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Czech Apr 1986. p. 51. Czechoslovakia Cechak, T. Kluson, J. Ceske

1986-04-01

399

Hard X-ray phase imaging and tomography using a grating interferometer  

International Nuclear Information System (INIS)

An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.

2007-07-01

400

Experimental study of X-ray vidicon  

International Nuclear Information System (INIS)

(1972). USSR Sviryakin, DI Manets, AI Kolupaev, AN v. 213 p. 111-114.

402

Electron-induced luminescence and x-ray spectrometer development: progress report  

Science.gov (United States)

The progress in the development of a surface analysis tool based on the excitation of characteristic

2003-01-01

403

Electron-Induced Luminescence and X-Ray Spectrometer (ELXS) System for Life Detection  

Science.gov (United States)

The ELXS concept is a novel, portable, micro-instrument targeted for the detection of mineralogic

2002-01-01

404

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

405

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

407

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds  

Energy Technology Data Exchange (ETDEWEB)

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds were studied by electron and proton bombardments. L{sub {gamma}1} X-rays which involve transition of 4d electrons of the valence shell were found to be sensitive to the chemical environment. The L{sub {gamma}1}/L{sub {beta}1} X-ray intensity ratio increased with an increase of the 4d electron occupation of niobium or molybdenum in niobium or molybdenum compounds, showing that the chemical effects can be ascribed to the 4d electron behavior of the metallic atom in its compounds. (orig.).

1990-12-20

408

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds  

International Nuclear Information System (INIS)

Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds were studied by electron and proton bombardments. L_#gamma#_1 X-rays which involve transition of 4d electrons of the valence shell were found to be sensitive to the chemical environment. The L_#gamma#_1/L_#beta#_1 X-ray intensity ratio increased with an increase of the 4d electron occupation of niobium or molybdenum in niobium or molybdenum compounds, showing that the chemical effects can be ascribed to the 4d electron behavior of the metallic atom in its compounds. (orig.).

1990-12-01

409

"2"0"3Pb yields while irradiating thallium with protons and deuterons  

International Nuclear Information System (INIS)

... data deuteron beams energy dependence errors gamma radiation lead 203

410

Study of the mass of the electron neutrino in Japan  

Energy Technology Data Exchange (ETDEWEB)

This report describes a study of the mass of the electron neutrino using electron capture in {sup 163}Ho in Japan for the period from 1981 to 1994. This monograph has two purposes, one is to supplement the papers on the mass of the electron neutrino already published by us and another is to make a record on some details of our experiments for future. Electron capture in a nucleus takes place in a rather small space inside an atom, where atomic physics, nuclear physics and particle physics work closely together. Therefore, this study needed an intimate collaboration of atomic physicists, nuclear physicists and particle physicists. In addition, it was necessary for this study to use various fine techniques, including metallurgy, production of {sup 163}Ho activity, micro-analysis by wet chemistry, isotope-dilution mass spectrometry, undulator radiation source technology, the soft X-ray monochromator technology, a counting technique for very intense soft ...

1996-02-01

411

A novel method to characterize the MTF in 3D for computed mammotomography  

Science.gov (United States)

A novel phantom has been developed to measure the modulation transfer function (MTF) in 3D for x-ray computed tomography. The phantom consists of three tungsten wires, positioned nearly orthogonal to each other. Simultaneous measurements of the MTF are taken at various locations along the three orthogonal reconstructed planes. Our computed mammotomography (CmT) system uses a Varian Paxscan 2520 digital x-ray detector which can be positioned anywhere in ~2pi steradian band and can have arbitrary trajectories. With a half-cone beam geometry and with the phantom positioned near the center of rotation, projection images are acquired over 360 degrees. Various 3D orbits are evaluated including vertical axis of rotation and saddle. Reconstructions were performed using an iterative ordered-subsets transmission algorithm on rebinned projection images, using various numbers of iterations. Rotation of reconstructed slices isolated ...

2006-03-01

412

Waves in pulsar winds  

International Nuclear Information System (INIS)

The radio, optical, x-ray and gamma-ray nebulae that surround many pulsars are thought to arise from synchrotron and inverse Compton emission. The energy powering this emission as well as the magnetic fields and relativistic particles are supplied by a 'wind' driven by the central object. The inner parts of the wind can be described using the equations of MHD, but these break down in the outer parts, when the density of charge carriers drops below a critical value. This paper reviews the wave properties of the inner part (striped wind), and uses a relativistic two-fluid model (cold electrons and positrons) to re-examine the nonlinear electromagnetic modes that propagate in the outer parts. It is shown that in a radial wind, two solutions exist for circularly polarized electromagnetic modes. At large distances one of them turns into a freely expanding flow containing a vacuum wave, whereas the other decelerates, corresponding to a confined flow.

2010-12-01

413

Validity of the CT to attenuation coefficient map conversion methods  

International Nuclear Information System (INIS)

The most important commercialized methods of attenuation correction in SPECT are based on attenuation coefficient map from a transmission imaging method. The transmission imaging system can be the linear source of radioelement or a X-ray CT system. The image of transmission imaging system is not useful unless to replacement of the attenuation coefficient or CT number with the attenuation coefficient in SPECT energy. In this paper we essay to evaluate the validity and estimate the error of the most used method of this transformation. The final result shows that the methods which use a linear or multi-linear curve accept a error in their estimation. The value of mA is not important but the patient thickness is very important and it can introduce a error more than 10 percent in the final result.

2004-04-27

414

Translocation of labelled sucrose: A student exercise  

Energy Technology Data Exchange (ETDEWEB)

Photosynthetic carbohydrates from the leaves are exported through the phloem to growing tips, roots, flowers and fruits. If sucrose labelled with {sup 14}C is applied to the leaves of bean plants, the pathway for sugar movement may be readily observed by autoradiography. Students apply the labelled sucrose during class time and return the next day to press their plants. During the next class, the pressed and dried plants are placed against X-ray film and left in the dark for four weeks. the film is then developed, examined for presence of label and compared to the pressed plants. Source to sink movement is clearly illustrated and information about the mechanism of phloem transport and loading is gained through experimental treatments, which include blocking the phloem pathway and inhibiting energy production.

1990-05-01

415

Thermonuclear burst physics with RXTE  

CERN Document Server

Recently we have made measurements of thermonuclear burst energetics and recurrence times which are unprecedented in their precision, largely thanks to the sensitivity of the Rossi X-ray Timing Explorer. In the "Clocked Burster", GS 1826-24, hydrogen burns during the burst via the rapid-proton (rp) process, which has received particular attention in recent years through theoretical and modelling studies. The burst energies and the measured variation of alpha (the ratio of persistent to burst flux) with accretion rate strongly suggests solar metallicity in the neutron star atmosphere, although this is not consistent with the corresponding variation of the recurrence time. Possible explanations include extra heating between the bursts, or a change in the fraction of the neutron star over which accretion takes place. I also present results from 4U 1746-37, which exhibits regular burst trains which are interrupted by "out of phase" bursts.

2004-01-01

416

Thermo-transferred thermoluminescence (TTTl) in potassium-yttrium double fluoride doped with terbium  

International Nuclear Information System (INIS)

This paper presents results of studying the thermo-transferred thermoluminescence (TTTl) phenomenon in potassium-yttrium double fluoride doped with terbium (K_2YF_5_:Tb) at different impurity concentrations (0.8%, 0.95% and 0.99%). Previously to study the TTTl phenomenon, structural characterization and chemical composition of the materials were determined. The structural studies were conducted using a scanning electron microscope; meanwhile, chemical composition was analyzed using energy dispersive X-ray spectroscopy. Thermoluminescence kinetics was studied irradiating the samples with "1"3"7Cs gamma rays as well as with "9"0Sr/"9"0Y beta rays, analyzing the glow curves by the deconvolution method for obtaining the kinetic parameters. (Author)

2011-02-01

417

The temporal evolution of coronal loops observed by GOES-SXI  

CERN Document Server

We study the temporal evolution of coronal loops using data from the Solar X-ray Imager (SXI) on board of GOES-12. This instrument allows us to follow in detail the full lifetime of coronal loops. The observed light curves suggest three somewhat distinct evolutionary phases: rise, main, and decay. The durations and characteristic timescales of these phases are much longer than a cooling time and indicate that the loop-averaged heating rate increases slowly, reaches a maintenance level, and then decreases slowly. This suggests that a single heating mechanism operates for the entire lifetime of the loop. For monolithic loops, the loop-averaged heating rate is the intrinsic energy release rate of the heating mechanism. For loops that are bundles of impulsively heated strands, it is an indication of the frequency of occurrence of individual heating events, or nanoflares. We show that the timescale of the loop-averaged heating rate is proportional ...

2006-01-01

418

The ribosome and the mechanism of protein synthesis  

Energy Technology Data Exchange (ETDEWEB)

In virtually all forms of life on earth, proteins in each cell are made according to a genetic blueprint, in the form of DNA. The translation of copies of this genetic blueprint (in the form of messenger RNA) into polypeptides is performed on the ribosome, a highly complex molecular machine composed of RNAs and proteins. To this end, special adaptor molecules called transfer RNAs are lined up by the ribosome in the sequence dictated by the genetic code, such that the amino acids carried by these molecules can be linked into a polypeptide. Several cofactors are involved in these processes, some of which require energy freed up by GTP hydrolysis. Although the ribosome was discovered more than 50 years ago, its structure has only been solved recently by X-ray crystallography. Another technique, cryo-electron microscopy, is starting to contribute toward our understanding of the ribosome's function, by portraying its conformational changes ...

2006-05-01

419

The mechanism of uranium biosorption by Rhizopus arrhizus  

Energy Technology Data Exchange (ETDEWEB)

Biosorption of elements is a little understood phenomenon exhibited by some types of even nonliving microbial biomass. A common fungus Rhizopus arrhizus has been reportd to take up uranium from adqueous solutions to the extent of 180 mg U/sup 6 +//g. The mechanism of uranium sequestering by this type of biomass was studied by using experimental techniques such as electron microscopy, x-ray energy dispersion analysis, IR spectroscopy, and supporting evidence was obtained for a biosorption mechanism consisting of at least three processes. Uranium coordination and adsorption in the cell-wall chitin structure occur simultaneously and rapidly whereas precipitation of uranylhdroxide within the chitin microcrystalline cell-wall structure takes place at a lower rate. Interference of Fe/sup 2/ and Zn/sup 2 +/ coions with uranium biosorption is indicated.

1982-02-01

420

Self-organization and electrical properties of Head-to-Tail poly(3-hexylthiophene) in Langmuir-Blodgett films  

Energy Technology Data Exchange (ETDEWEB)

The conductive ultra thin films were fabricated from mixed monolayers containing stearic acid and Head-to-Tail poly(3-alkylthiophene). These films exhibited well-defined layered structures as determined by optical absorption and X-ray diffraction measurements. The UV-Vis absorption spectra of these films showed lower energy absorption shifts of 48 nm from that of the random poly(3-alkylthiophene)/stearic acid LB films. The blue shift of absorption maximum of the LB film is attributed to the increase of {pi}-conjugation length caused by no steric hindrance of alkyl side chains. The conductivity of the Head-to-Tail poly(3-hexylthiophene)/stearic acid LB films was greatly improved in the range of 67-100 S/cm. (orig.)

1997-01-01

421

Radiation treatment of medical devices and packaging materials. Pt. 1  

International Nuclear Information System (INIS)

The first part of the study contains a literature compilation of more than 50 original publications reporting the radiation induced effects in 17 different high polymer materials and glass which are relevant in the manufacturing of medical devices or packing materials. The results collected demonstrate that high energy radiation, i.e. gamma- or X-rays, causes various physical and chemical alterations in high polymer materials. A detailed summary and discussion of the results of the original publications is not included in the present report, it will be presented in the second part of the study. Furthermore, the second part of the study will refer to the aspect of wholesomeness of irradiated medical devices or packing materials in a more general manner of representation. (orig.).

422

Radiation hazard control report  

Energy Technology Data Exchange (ETDEWEB)

The radiation control carried out in Atomic Energy Research Institute, Kinki University, for the reactor installation and the tracer/accelerator facilities from April, 1981, to March, 1982, is described. The reactor was operated for total 1057.1 hours at the maximum heat output of 1 W. The persons subject to radiation protection as of April, 1981, were 126 persons in all, including 23 in radiation work and 11 in X-ray work, etc. The contents of this report are as follows: personnel monitoring (health examination, the control of individual exposure dose); laboratory monitoring (the measurement of area dose rate, radioactive concentration in air and water, and surface contamination density); field monitoring (environmental ..gamma..-ray dose rate, radioactive concentration in environmental samples); the use of unsealed radioisotopes, etc.

1982-12-01

423

Phase formation sequence in the Pd-GaAs system  

Energy Technology Data Exchange (ETDEWEB)

The morphological aspects of ternary phase formation during the Pd-GaAs reaction have been studied by application of transmission electron microscopy (TEM) and Rutherford backscattering (RBS) techniques. The TEM images show that the first product phase, ''phase I'', forms during deposition of Pd onto (100) GaAs and exhibits the preferred orientation (0001)/sub I/ approx. // (01 anti 1)/sub GaAs/. In the presence of unreacted Pd, the second phase, ''phase II'', nucleates at large-angle grain boundaries in the phase I film as the annealing temperature increases above approx.250C. Energy dispersive analysis of x-rays and RBS suggest the nominal compositions Pd3GaAs and Pd4GaAs for phases I and II, respectively.

1985-12-01

424

Near-edge structures from first principles all-electron Bethe-Salpeter equation calculations  

International Nuclear Information System (INIS)

We obtain x-ray absorption near-edge structures (XANES) by solving the equation of motion for the two-particle Green's function for the electron-hole pair, the Bethe-Salpeter equation (BSE), within the all-electron full-potential linearized augmented plane wave method (FPLAPW). The excited states are calculated for the Li K-edge in the insulating solids LiF, Li_2O and Li_2S, and absorption spectra are compared with independent particle results using the random phase approximation (RPA), as well as supercell calculations using the core-hole approximation within density functional theory (DFT). The binding energies of strongly bound excitations are determined in the materials, and core-exciton wavefunctions are demonstrated for LiF.

2009-03-11

425

LDEF impact craters formed by carbon-rich impactors  

International Nuclear Information System (INIS)

Two small craters (number 74, 119 microns, and number 31, 158 microns in diameter) with depth to diameter ratios of about 0.59 and 0.8, respectively, were found in Al from the Long Duration Exposure Facility (LDEF) experiment tray A11EOOF. Both craters have residues concentrated in the crater bottoms, along the walls, and on top of the overturned rims. Low voltage scanning electron electron microscopy, Auger electron spectroscopy, time of flight secondary ion mass spectroscopy and energy dispersive x-ray spectroscopy were used to obtain high resolution imagery and elemental analysis. Analyses indicate that the impactor for both craters was carbon-rich, as the residues contain mostly C. Silicon, S, and F in low concentrations are present on the Al surface away from the craters and may be, in part, contaminants.

1991-06-01

426

Hydriding properties of a mechanically milled Mg-50 wt.% ZrFe{sub 1.4}Cr{sub 0.6} composite  

Energy Technology Data Exchange (ETDEWEB)

The ball-milling method was used to produce Mg-50 wt.% ZrFe{sub 1.4}Cr{sub 0.6} composite. The thermodynamic, kinetic, and cycling properties, as well as the resistance to oxidation were examined. This composite possesses excellent kinetic properties, even at moderate temperature. Scanning electron microscopy, energy-dispersive spectrum, transmission electron microscopy and X-ray diffraction were used to characterize the composite before and after hydriding. The fine ZrFe{sub 1.4}Cr{sub 0.6} particles covering Mg particles acting as a ''catalytic film'', a significant amount of imperfections and some alloy powder in the Mg matrix introduced by ball milling all contributed to the enhanced absorption/desorption rate. (orig.)

2000-02-02

427

High coercivity in Nd-Fe-Al-Co-B alloys prepared by mechanical milling  

Energy Technology Data Exchange (ETDEWEB)

Nd{sub 40}Fe{sub 30}Al{sub 10}Co{sub 15}B{sub 5} alloys were fabricated by high energy ball milling method under various conditions. Microstructure of the alloys was investigated by X-ray diffraction and electron microscopy techniques. Magnetic properties were characterized by hysteresis and thermomagnetic measurements. The high coercive fields up to 2.36 T have been observed on the samples consisting of Nd{sub 2}(Fe,Co,Al){sub 14}B, Nd{sub 6}(Fe,Co,Al){sub 14} and Nd crystallites imbedded in a residual amorphous matrix.

2008-02-15

428

Graphene-Pt nanocomposite for nonenzymatic detection of hydrogen peroxide with enhanced sensitivity  

British Library Electronic Table of Contents (United Kingdom)

A sensitive hydrogen peroxide (H2O2) sensor was fabricated based on graphene-Pt (GN-Pt) nanocomposite. The GN-Pt was synthesized by photochemical reduction of K2PtCl4 on GNs, and characterized by atomic force microscope (AFM), transmission electron microscope (TEM), and energy-dispersive X-ray spectroscopy (EDS). Electrochemical investigations indicated that the GN-Pt exhibited a high peak current and low overpotential towards the reduction of H2O2. The GN-Pt modified glass carbon electrode displayed a wide linear range (2-710mM), low limit of detection (0.5mM) and good selectivity for detection of H2O2 with a much higher sensitivity than that of Pt nanoparticles or graphene modified electrode.

2011-01-01

429

Effect of minor alloying elements and their segregation on void suppression in modified 316 stainless steel  

International Nuclear Information System (INIS)

The effects of modification with Ti and Nb, heat treatment and solute segregation on void suppression in 316 stainless steel were studied using HVEM in the temperature range of 623-873 K after solution treatment at 1323-1473 K. Post-irradiation compositional analysis was performed by an energy dispersive X-ray analyzer. In Ti-modified stainless steel, void swelling peaks appeared at 723 K and 823 K. On the other hand, when the stainless steels modified by both Ti and Nb were irradiated, the void swelling was effectively suppressed, particularly the growth rate of a void was remarkedly retarded. This void suppression effect was easily recognized with increasing Nb concentration. Compositions such as Mo, Cr, Ti and Ni changed during irradiation and Ni, Si and Ti enriched around voids, whereas Cr and Mo depleted. (orig.).

1983-09-01

430

Double peak effect in microdosimetric proportional counters and its interpretation  

Energy Technology Data Exchange (ETDEWEB)

In calibration measurements with low energy X-rays, a double peak effect appears in low pressure proportional counters with a helix, when used for simulation of tissue equivalent diameters considerably larger than 2 m. An interpretation of this phenomenon is discussed, based upon electron capture and electric field perturbation at the counter helix. A description of the physical processes is presented showing that the double peak effect is a problem in the case of helix counters (called also Rossi counters) for all simulated diameters. Conclusions are drawn on systematic errors introduced by the counter helix into microdosimetric spectra and anti y/sub D/ of photons and neutrons. The authors recommend to use cylindrical counters with optimized geometrical and electronic parameters rather than the spherical counters with a helix discussed.

1989-01-01

431

Biosorption of lead by citrobacter freundii immobilized on hazelnut shells  

Energy Technology Data Exchange (ETDEWEB)

Biosorption of lead from aqueous solutions by living and immobilized cell of C. freundii was examined as a function of metal concentration in a batch laboratory bioreactor. Lead concentrations were analyzed using Atomic Absorption Spectrophotometer (AAS). X-ray Energy Dispersion (EDX) analyses were made in order to determine the accumulation of lead on the cells and shell surfaces. Before and after the experiments the biomaterials and adsorbents were examined by Scanning Electron Microscopy (SEM). Biosorption was detected over a range of initial lead concentrations from 25{times}10{sup -3} to 200{times}10{sup -3} kg/m{sup 3}. 15 refs., 4 figs.

1996-12-31

432

Bandgap properties of the indium sulfide thin-films grown by co-evaporation  

British Library Electronic Table of Contents (United Kingdom)

In the present study the optical properties of co-evaporated indium sulfide thin films are investigated. Before being optically characterized, the composition as well as the crystalline properties of the film have been checked with the help of energy dispersive spectroscopy (EDX) and X-Ray diffraction (XRD) analyses. The optical absorption coefficient ? of this indium sulfide film has been deduced from reflectivity R(?) and transmission T(?) measurements. The fit of the curve representing ?(h?) suggests that the ?-In2S3 has an indirect bandgap of 2.01?eV. Density functional theory (DFT) calculations are performed on this indium sulfide compound, using TB-LMTO code. Through these band structure investigations, an indirect bandgap is predicted as observed experimentally. The top of the valen...

2009-01-01

433

Banana peel extract mediated novel route for the synthesis of palladium nanoparticles  

British Library Electronic Table of Contents (United Kingdom)

Bio-inspired palladium nanoparticles were synthesized by using banana peel extract (BPE), a non-toxic eco-friendly material. Boiled, crushed, acetone precipitated, air-dried peel powder was used to reduce palladium chloride. The palladium nanoparticles were characterized by using UV-Visible spectroscopy, scanning electron microscope-energy dispersive spectra (SEM-EDS) and X-ray diffraction (XRD) analysis. Dynamic light scattering (DLS) studies revealed the average size of nanoparticles to be 50nm. Fourier transform infra red spectroscopy (FTIR) implicated the role of carboxyl, amine and hydroxyl groups in the synthetic process. This paper thus describes a novel green method for the synthesis of palladium nanoparticles.

2010-01-01

434

Applications of environmental scanning electron microscopy (ESEM) in the study of novel drying latex films  

Energy Technology Data Exchange (ETDEWEB)

We have employed Environmental Scanning Electron Microscopy (ESEM) and Energy Dispersive X-ray (EDX) analysis to study the microstructural evolution of acrylic latex stabilised with a novel polysaccharide derived from agricultural waste. The analysis revealed that the micro structure of the latex in the 'wet' state consists of individual particles and clusters. Upon evaporation a discontinuous film is formed, with voids present within its structure, which is inconsistent with the conventional descriptions of film formation. Further ESEM examination of 'dry' specimens revealed that aging resulted in the formation of dendritic structures on the surfaces of the latex films, which EDX analysis confirmed to have been formed via crystallisation of salt. The experimental evidence suggests that the clusters, which are part of the structure of the latex, may act as nucleation centres that would allow the dendrites to ...

2008-08-15

435

An in situ observation of the growth kinetics and stress relaxation Pd sub 2 Si thin films on Si(111)  

Energy Technology Data Exchange (ETDEWEB)

The growth of the Pd{sub 2}Si thin fllms on Si(111) substrates has been monitored by an {ital in} {ital situ} x-ray diffraction technique in vacuum and in helium atmosphere from 160 to 250 {degree}C. A familiar parabolic growth rate was found, confirming the diffusion-controlled film growth process. The activation energies were found to be 1.34 and 1.37 eV for the measurements performed in vacuum and helium environment, respectively. Stress relaxation in the growing Pd{sub 2}Si fllm was observed when the reaction temperature exceeds 200 {degree}C. The relaxed films showed a higher degree of texture as evidenced by the rocking curve measurements.

1990-04-15

436

An in situ observation of the growth kinetics and stress relaxation Pd sub 2 Si thin films on Si(111)  

Science.gov (United States)

The growth of the Pd{sub 2}Si thin fllms on Si(111) substrates has been monitored by an {ital in} {ital situ} x-ray diffraction technique in vacuum and in helium atmosphere from 160 to 250 {degree}C. A familiar parabolic growth rate was found, confirming the diffusion-controlled film growth process. The activation energies were found to be 1.34 and 1.37 eV for the measurements performed in vacuum and helium environment, respectively. Stress relaxation in the growing Pd{sub 2}Si fllm was observed when the reaction temperature exceeds 200 {degree}C. The relaxed films showed a higher degree of texture as evidenced by the rocking curve measurements.

1990-04-15

437

A micro-alloyed ferritic steel strengthened by nanoscale precipitates  

British Library Electronic Table of Contents (United Kingdom)

A ferritic steel with finely dispersed precipitates was investigated to reveal the fundamental strengthening mechanisms. The steel has a yield strength of 760MPa, approximately three times higher than that of conventional Ti-bearing high strength hot-rolled sheet steels, and its ultimate tensile strength reaches 850MPa with an elongation-to-failure value of 18%. Using energy dispersive X-ray spectroscopy (EDXS) and transmission electron microscope (TEM), fine carbides TiC with an average diameter of 10nm were observed in the ferrite matrix of the 0.08%Ti steel, and some cubic M23C6 precipitates were also observed at the grain boundaries and the interior of the grains. The finely dispersed TiC precipitates in the matrix provide matrix strengthening. The estimated magnitude of precipitation ...

2011-01-01

438

X-ray findings in patients with miliary appearance of metallic mercury after suicide attempt  

Energy Technology Data Exchange (ETDEWEB)

This case report evaluates X-ray findings in patients with miliary accumulation of mercury observed after parenteral application of metallic mercury in a suizide attempt. There are certain discrepancies between clinical symptoms and the X-ray findings. A clear demonstration of mercury in coronary blood vessels is possible by fluoroscopy.

1985-03-01

439

Radionuclide X-ray fluorescence analysis of components of the environment  

International Nuclear Information System (INIS)

The physical foundations and methodology are described of radionuclide X-ray fluorescence analysis. The sources are listed of air, water and soil pollution, and the transfer of impurities into biological materials is described. A detailed description is presented of the sampling of air, soil and biological materials and their preparation for analysis. Greatest attention is devoted to radionuclide X-ray fluorescence analysis of the components of the environment. (ES).

1983-01-01

440

Quantitative phase imaging using hard x-rays  

International Nuclear Information System (INIS)

The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.

2009-02-01

441

Present state of radionuclide X-ray fluorescence analysis in coal mining  

International Nuclear Information System (INIS)

Applications of X-ray fluorescence analysis in coal mining and geology are briefly described based on results published in Czechoslovakia as well as abroad over the past 3 years. Particular attention is paid to the rapid determination of the ash content of coal using portable radionuclide X-ray fluorescence analyzers that are being developed in Czechoslovakia. (author).

1990-01-01

442

Pd-Na/F double exploding foil photoionization experiment  

Science.gov (United States)

The achievement of inner-shell photoionization of Zn-like Pd by means of two exploding foils is described. This resulted in the soft X-ray transition 3d94s2-3d104p at 46 A. It is shown that the photoionization of inner shell electrons in highly stripped ions can lead to X-ray transitions which may be candidates for X-ray lasers under 50 A.

1990-03-01

443

Nondestructive determination of airborne lead particulates by the radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).

1980-01-01

444

Genetic and somatic risks in X-ray diagnosis  

International Nuclear Information System (INIS)

Based on a literature study an actual summary of the risk-utility problems in X-ray diagnosis is outlined due to the Recommendations of the International Commission for Radiation Protection (ICRP publication 26/1977). Papers demonstrating quantitative assessment of the somatic and genetical risk in X-ray examination are preferably cited and evaluated. It is concluded that the somatic and genetical risk is low in diagnostic ratiology. However, it must not be neglected and has always to be compared to the utility of an examination as well as to other risks of the examination. (author).

1982-01-01

445

From tomography to voludensitometry: radiation detectors for industrial control and medical instrumentation; De la tomographie a la voludensitometrie: les capteurs pour le controle industriel et l`instrumentation medicale  

Energy Technology Data Exchange (ETDEWEB)

In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).

1993-12-01

446

Determination of ash in coal by X-ray backscattering and X-ray fluorescence analysis and apparatus by the PAR company  

International Nuclear Information System (INIS)

The basic principles of determination of the ash content of coal by the title methods are outlined. A brief technical characteristic of the ash meters and radionuclide X-ray fluorescence analyzers manufactured by the PAR company is presented. (Z.S.). 4 figs., 7 refs.

1993-01-01

447

Contribution to the in vitro multielement X-ray fluorescence analysis of human soft tissues  

International Nuclear Information System (INIS)

Determination of Mn, Fe, Ni, Cu, Zn, and Pb in human soft tissues by radionuclide X-ray fluorescence analysis (using "2"3"8Pu and "1"0"9Cd sources) is described. The results of multielement XRS analysis of selected human tissues are tabulated. They are in good agreement with the literature data. It is concluded that X-ray fluorescence technique is a suitable method for trace element determination. (author).

1986-11-01

448

Design of a tandem accelerator free electron laser  

International Nuclear Information System (INIS)

The motivation for using a tandem electrostatic accelerator as an electron accelerator for a free electron laser (FEL) is presented. The adaptation of the HVEC EN tandem at the Weizmann Institute for this purpose, electron beam optics and nonlinear FEL computation relevant for this FEL realization are described. In the tandem configuration the terminal is held at a positive potential. The electron beam is accelerated from ground potential to the terminal in one beam tube and then decelerated down the other beam tube. The FEL wiggler and cavity are at the terminal. Due to the beam energy recovery this scheme produces a high power beam at the terminal with a small investment in electrical power. (orig.).

449

Centroid and Envelope Dynamics of High-intensity Charged Particle Beams in an External Focusing Lattice and Oscillating Wobbler  

Energy Technology Data Exchange (ETDEWEB)

The centroid and envelope dynamics of a high-intensity charged particle beam are investigated as a beam smoothing technique to achieve uniform illumination over a suitably chosen region of the target for applications to ion-beam-driven high energy density physics and heavy ion fusion. The motion of the beam centroid projected onto the target follows a smooth pattern to achieve the desired illumination, for improved stability properties during the beam-target interaction. The centroid dynamics is controlled by an oscillating "wobbler", a set of electrically-biased plates driven by RF voltage. __________________________________________________

2010-04-28

450

Angular scattering in electron capture and loss D/sup -/ beam formation processes  

Energy Technology Data Exchange (ETDEWEB)

The development of high energy (> 150 keV) neutral beams for heating and fueling magnetic fusion devices depends on the ability to produce well-collimated negative ion beams. The double capture charge-exchange technique is a known, scalable method. In order to maximize the overall efficiency of the process and to achieve the desired beam characteristics, it is necessary to examine the optical qualities of the beams as well as the total efficiency of beam production. A combined modeling and experimental study of the angular scattering effects in negative ion formation and loss processes has therefore been undertaken.

1980-01-01

451

In-beam #gamma#-ray spectroscopy of fast beams at the NSCL  

International Nuclear Information System (INIS)

With the development of an array of highly-segmented germanium detectors, it now becomes possible to perform in-flight #gamma#-ray spectroscopy experiments on intermediate energy beams with unprecedented #gamma#-ray energy resolution. Presented in this report are examples of two techniques in which SeGA, the most highly-segmented operational germanium array for in-flight spectroscopy with fast beams, was used for the detection of #gamma# rays. SeGA used in conjunction with a high-resolution magnetic spectrograph (S800) to detect the reaction residues in coincidence represents a powerful combination for in-beam #gamma#-ray studies.

2004-04-05

452

Large perpendicular magnetic anisotropy of ultrathin Ru and Rh films on a NiAl(001) surface  

International Nuclear Information System (INIS)

Using the full potential linearized augmented plane wave (FLAPW) method, the magnetic properties of two-dimensional Ru and Rh monolayers (MLs) on a NiAl(001) surface have been investigated. It has been found that free standing one monolayer Ru and Rh films have ferromagnetic ground state with magnetic moments of 2.21 and 1.48 #mu#_B, respectively. The ferromagnetism is still observed even on a Ni terminated NiAl(001) surface, while no magnetic state is found on an Al terminated surface. The calculated magnetic moments of Ru and Rh atoms are 1.56 and 0.88 #mu#_B, respectively. In addition, an induced magnetic moment in surface Ni is observed. It has been found that the free standing Ru film has perpendicular magnetization to the film surface with a magnetocrystalline anisotropy (MCA) energy of 0.66 meV/atom, while an in-plane MCA energy of 0.37 meV/atom is achieved in Rh film. Very interestingly, we find that both Ru/NiAl(001) and Rh/NiAl(001) ...

2010-10-27

453

The propagation of relativistic heavy ions in multielement beam lines.  

Science.gov (United States)

We describe calculations of the energy loss, range, stopping power, multiple scattering, and other related properties of a high-energy heavy-ion beam at any one of a set of beam line elements. A beam line element (e.g., any beam modification, detection, or control device) is characterized by its thickness, areal density, aperture, and function. The loss of multiply scattered particles to any finite-aperture detector is calculated in the small-angle approximation, and the position of the Bragg peak, as given by particles stopping in the second of two ionization chambers used for Bragg curve measurements, is estimated. A general purpose computer program, PROPAGATE, has been written to allow addition, deletion, and modification of the beam line elements used in the calculation and to provide a convenient means of repeating such calculations for ...

454

Electron detachment cross-sections and secondary-electron emission factors for heavy-negative-ion beams  

Energy Technology Data Exchange (ETDEWEB)

The properties of negative-ion beams are very important for designing negative-ion apparatus and applications of negative-ion beams, especially, electron detachment cross-sections at the interaction between negative-ion beams and gas particles in the transport system, and secondary-electron emission factors when negative ions are incident on solid surfaces. These properties of negative-ion beams were investigated experimentally as a function of the ion energy under 50 keV. The single electron detachment cross-sections are almost constant in the other of 10[sup -15] cm[sup 2] in this energy range, but double electron detachment cross-sections increase in proportion to the ion velocity and much smaller than the single one. As for the secondary-electron emission factor, the emission factors for negative-ion beam are found to be larger by 1 than ...

1994-01-01

455

Electron detachment cross-sections and secondary-electron emission factors for heavy-negative-ion beams  

International Nuclear Information System (INIS)

The properties of negative-ion beams are very important for designing negative-ion apparatus and applications of negative-ion beams, especially, electron detachment cross-sections at the interaction between negative-ion beams and gas particles in the transport system, and secondary-electron emission factors when negative ions are incident on solid surfaces. These properties of negative-ion beams were investigated experimentally as a function of the ion energy under 50 keV. The single electron detachment cross-sections are almost constant in the other of 10"-"1"5 cm"2 in this energy range, but double electron detachment cross-sections increase in proportion to the ion velocity and much smaller than the single one. As for the secondary-electron emission factor, the emission factors for negative-ion beam are found to be larger by 1 than those ...

1994-01-01

456

Influence of the X-ray radiation on the lifetime of carriers in the p-n junctions of Si and Ge  

International Nuclear Information System (INIS)

Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of lifetime of the charge carriers with the increase of X-ray radiation dose.

457

Gauging film thickness: A comparison of an x-ray diffraction technique with Rutherford backscattering spectrometry  

Energy Technology Data Exchange (ETDEWEB)

An x-ray diffraction technique for determining thin-film thickness is presented which should prove to be a valuable alternative to the array of spectroscopies (Rutherford backscattering spectrometry, Auger electron spectroscopy, etc.) currently favored for these measurements. Some of the virtues of this x-ray diffraction approach are its nondestructive nature, fast data acquisition rate (enabling in situ observations), thickness resolution better than 5 nm, and conventional equipment requirements. Results are shown for Pd/sub 2/Si thin films grown during isothermal annealing of Pd coatings (100 nm) on Si at 200 /sup 0/C for various amounts of time. A comparison of these x-ray measurements with Rutherford backscattering spectrometry data taken from the same specimens is used to demonstrate the validity of the x-ray technique.

1985-01-15

458

Fully Coherent X-ray Pulses from a Regenerative Amplifier Free Electron Laser  

Energy Technology Data Exchange (ETDEWEB)

We propose and analyze a novel regenerative amplifier free electron laser (FEL) to produce fully coherent x-ray pulses. The method makes use of narrow-bandwidth Bragg crystals to form an x-ray feedback loop around a relatively short undulator. Self-amplified spontaneous emission (SASE) from the leading electron bunch in a bunch train is spectrally filtered by the Bragg reflectors and is brought back to the beginning of the undulator to interact repeatedly with subsequent bunches in the bunch train. The FEL interaction with these short bunches not only amplifies the radiation intensity but also broadens its spectrum, allowing for effective transmission of the x-rays outside the crystal bandwidth. The spectral brightness of these x-ray pulses is about two to three orders of magnitude higher than that from a single-pass SASE FEL.

2006-02-17

459

Collisional Cooling of Negative Ion Beams  

Science.gov (United States)

Investigations have been conducted to determine the feasibility of using collisional cooling for reducing the energy spreads and, consequently, the emittances of negative-ion beams. We have designed a gas-filled RF-quadrupole ion cooler equipped with provisions for retarding energetic negative ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to high energies after the cooling process. The device has been used to cool O{sup -} and F{sup -} ion beams with initial energy spreads, {Delta}E > 10 eV to final energy spreads, {Delta}E {approx} 2 eV FWHM. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been obtained. Experimental results show that electron detachment is the major loss mechanism for negative ions.

2001-06-29

460

Collisional Cooling of Negative Ion Beams  

Energy Technology Data Exchange (ETDEWEB)

Investigations have been conducted to determine the feasibility of using collisional cooling for reducing the energy spreads and, consequently, the emittances of negative-ion beams. We have designed a gas-filled RF-quadrupole ion cooler equipped with provisions for retarding energetic negative ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to high energies after the cooling process. The device has been used to cool O{sup -} and F{sup -} ion beams with initial energy spreads, {Delta}E > 10 eV to final energy spreads, {Delta}E {approx} 2 eV FWHM. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been obtained. Experimental results show that electron detachment is the major loss mechanism for negative ions.

2001-06-29

461

In-beam spectroscopy of nuclei  

International Nuclear Information System (INIS)

The main features and advantages of a new low energy nuclear spectroscopic method, the in-beam spectroscopy are described. Results of in-beam spectroscopic experiments performed at the Institute of Nuclear Research (ATOMKI, Debrecen, Hungary) are summarized. Gamma spectra of in-beam produced odd-odd nuclei were measured, gamma-energies were determined. Measurement of gamma-gamma coincidences led to the construction of energy level schemes of the investigated nuclei. Internal conversion electron spectroscopy was used to determine the multipolarities of transitions. A few spectra and level schemes are presented to illustrate the review. Theoretical interpretation of experimental results are briefly summarized. (D.Gy.).

1982-01-01

462

Chargino production at high energy {gamma}{gamma} colliders with polarized beams  

Energy Technology Data Exchange (ETDEWEB)

We investigate the chargino production process {gamma}{gamma} {yields} (W-tilde){sup +}(W-tilde){sup -} at high energy {gamma}{gamma} colliders in the framework of the minimal supersymmetric standard model (MSSM). Here the high energy {gamma} beams are obtained by the backward Compton scattering of the laser flush by the electron in the basic linear TeV ee colliders. We consider the polarization of the laser photons as well as the electron beams. Appropriate beam polarization could be effective to enhance the cross section to for us extract the signal from the dominant background {gamma}{gamma} {yields} W{sup +}W{sup -}. (author).

1995-05-01

463

Chargino production at high energy #gamma##gamma# colliders with polarized beams  

International Nuclear Information System (INIS)

We investigate the chargino production process #gamma##gamma# #-># (W-tilde)"+(W-tilde)"- at high energy #gamma##gamma# colliders in the framework of the minimal supersymmetric standard model (MSSM). Here the high energy #gamma# beams are obtained by the backward Compton scattering of the laser flush by the electron in the basic linear TeV ee colliders. We consider the polarization of the laser photons as well as the electron beams. Appropriate beam polarization could be effective to enhance the cross section to for us extract the signal from the dominant background #gamma##gamma# #-># W"+W"-. (author).

1995-05-01

464

The free electron laser klystron amplifier concept  

International Nuclear Information System (INIS)

The simplest high gain free electron laser (FEL) amplifier concept is proposed. A klystron amplifier has the useful property that the various electronic processes take place in separate portions of the amplifier, rather than overlapping as in FEL amplifier with an uniform undulator. The klystron consists of two fundamental parts: succession of 2-3 cascades (modulator), and an output undulator (radiator) in which the modulated electron beam coherently radiates. Each cascade consists of uniform undulator and dispersion section. Unlike distributed optical klystrons, we have a high gain per cascade pass. This has a few consequences. First, klystron gain does not depend on the bunch compression in the injector linac, i.e. maximum gain per cascade pass at high peak beam current is the same at low peak beam current, without compression. Conventional, short-wavelength FEL amplifier and distributed optical klystron require electron ...

465

Quality control in medical radiology using T.L.D  

Energy Technology Data Exchange (ETDEWEB)

In this work tests of quality control in beams of X rays have been carried out, at diagnostic level, of two radiological services equipments of Brazilian hospitals (Aracaju, SE). We obtained the air kerma and kerma rate values, the beams efficiency, the coherence between the luminous fields and the referring fields of irradiation and half-value layer to each equipment and set of parameters. The measures of direct form have been obtained using two ionization chambers, one cylindrical and another one with parallel plates. An optional method for accomplishment some of the tests were carried out with CaSO{sub 4}:Dy + Teflon thermoluminescent dosimeters. The values of air kerma were evaluated for three tube voltage, 40, 60 and 81 kV at 1.0 m from the focus of the equipments. For each one of the voltages three distinct current values were chosen besides a fixed value of exposition time. The results showed ...

2006-07-01

466

Synchrotron resource of the Howard Hughes Medical Institute  

Energy Technology Data Exchange (ETDEWEB)

The Synchrotron Resource of the Howard Hughes Medical Institute will be dedicated to structural analyses of biological macromolecules, primarily through crystallography. This facility is under construction at the X4 port of the National Synchrotron Light Source at Brookhaven National Laboratory, and it will comprise three beamlines. The first line to be built has been devised to apply the multiwavelength anomalous diffraction method which provides direct estimates for the phases of reflections. The second line will be devoted to rapid and essentially routine diffraction measurements, mainly through the rotation method. These two experimental stations are contained within refrigerated radiation enclosures that will maintain clean environments, narrowly defined constant temperatures, and protection against biohazard at biosafety level BL-2. At the same time as the second line will be developed, the swath center is planned to first serve as a monitor of the white ...

1989-07-01

467

Study of spatial resolution in three-dimensional rotational angiography  

International Nuclear Information System (INIS)

In interventional radiology (IVR) of cerebral aneurysms, it is important to understand the form and physical relationships between the cerebral aneurysm and the surrounding vessels. However, because the vessels in the head area are highly complex, it can be difficult to comprehend the structure using conventional angiography. Therefore, three-dimensional rotational angiography (3D-RA) has been used in recent years. This article discusses studies of the spatial resolution of 3D-RA. We reconstructed 3D-RA of an acrylic slit phantom (slit widths: 0.5, 0.75, 1.0, 1.5 mm) and examined spatial resolution by visual evaluation and profile curves. When the slit phantom was arranged to avoid the effect of beam hardening, the spatial resolution of 3D-RA was found to be as high as 0.75 mm. When the slit phantom was placed orthogonal to the rotational axis of the C-arm, the spatial resolution of 3D-RA was decreased because of the cone angle effect of ...

2006-03-01

468

Optical and structural properties of Ge films from ion-assisted deposition  

International Nuclear Information System (INIS)

The optical properties and microstructure of germanium (Ge) films, prepared by ion-assisted deposition (IAD) process, were investigated. The Ge films were deposited on sapphire and silicon substrates, with and without simultaneous Ar+ bombardment. Higher index films, with a refractive index 7.7% larger than that of the single crystalline Ge wafer, were obtained with the IAD process. The density of the IAD film could be 1.5% greater than that of the e-beam film. The results of the heat treatment indicated that the optical and structural properties of the IAD films were more stable. Ge nano-crystallites could be observed under high ion power density, which induced a crystalline structure in the Ge thin films. The average size of the nano-crystallites, as determined from both the X-ray diffraction data and the transmission electron microscopy images, showed that no systematic change had occurred. The results presented in this work suggest that the ...

2008-11-28

469

Laser induced local and periodic phase transformations in iron oxide thin films obtained by chemical vapour deposition  

International Nuclear Information System (INIS)

Iron oxide films have been deposited on Si(100) substrates by chemical vapour deposition (CVD) of iron(III) tert-butoxide ([Fe(O "tBu)_3]_2) in the temperature range 350-450 deg. C. The precursor flux and substrate temperature were varied to control the phase composition, average grain size and film thickness. The nature of substrate and deposition temperature markedly influence the morphology and iron-oxygen stoichiometry in the CVD deposits. Phase transformations in iron oxide films were achieved through precise local and periodic heating of the films by interfering laser beams. The interaction of iron oxide films with short laser pulses (Nd:YAG, 355 nm) induced partial transformation of hematite (#alpha#-Fe_2O_3) to magnetite (Fe_3O_4) or magnetite to wuestite (Fe_1_-_xO), respectively. The phase characterization and morphology of the hematite and magnetite films were investigated before and after laser irradiation by X-ray diffractometry, ...

2005-07-15

470

Fluid flow visualization with neutron radiography  

International Nuclear Information System (INIS)

A technique was developed that permits fluid flow to be visualized even where the flow is completely shrouded by metal. The technique employs real-time neutron radiography, which is similar to x-ray radiography except a collimated beam of neutrons is used. Various combinations of neutron-opaque tracer materials were tested with neutron-transparent fluid. Neutron opaque tracers, such as solid particles, fluid droplets, and streaklines were imaged through metal walls as they convected in neutron-transparent ambient fluid. Visualization of bubbles/voids were evaluated for possible future applications. Surface-flow patterns were also imaged by using neutron-opaque tufts. These techniques were evaluated for image contrast, resolution, and the ability to accurately track fluid flow fields. The techniques were also modeled to optimize contrast in various flow configurations. Imaging techniques such as real-time video, high speed video, and ...

1764-01-01

471

Development and clinical experience of C-arm type radiosurgery system or three dimensional therapy system  

Energy Technology Data Exchange (ETDEWEB)

Authors developed a C-arm type radiosurgery system of the linear accelerator suitable for stereotactic radiation therapy and a software for arranging 3-dimensional therapy in the system. In this system, the gantry far conical irradiation of 4 MV (0.6-3 Gy/min) and 6 MV (0.9-4.5 Gy/min) X ray or electron beam for the therapy was connected to a newly designed C-arm and was made capable of rotating around either of the axes crossing vertically. With this system, it became unnecessary to move the bed table of the patient for getting suitable distribution of radiation dose. The local accuracy which was measured by the CCD videocamera on the gantry, was within 0.5 mm from the radiation center. The system made it possible to shorten the irradiation time and to improve the local accuracy of irradiating site. The clinical trial was begun from June, 1996. (K.H.)

1996-10-01

472

Detection of Second-Layer Corrosion in Aging Aircraft Fuselage  

International Nuclear Information System (INIS)

A Digital X-ray imaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS method): A simple reconstruction model is also ...

2006-12-01

473

Dependence of anomalous phosphorus diffusion in silicon on depth position of defects created by ion implantation  

Energy Technology Data Exchange (ETDEWEB)

Transient enhanced diffusion of phosphorus in silicon has been investigated for implants below and above the threshold for a complete amorphization. Rapid thermal processes (electron beam) and conventional furnaces have been used for the annealing. In the case of implants below amorphization, a strong enhanced diffusion, proportional to the amount of damage produced, has been observed. The extent of the phenomenon is practically independent of the damage depth position. In contrast to this, the formation of extended defects at the original amorphous-crystalline interface makes the diffusivity strongly dependent on depth in the case of post-amorphized samples. No enhanced diffusion effect is observed if the dopant is confined in the amorphous layer, while a remarkable increase in the diffusivity is detected for the dopant located in the crystalline region beyond the amorphous-crystalline interface. Damage distribution after implantation and its evolution during ...

1989-03-01

474

Alternate Tunings for the Linac Coherent Light Source Photoinjector  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) is an x-ray free-electron laser (FEL) project based on the SLAC linac. The LCLS Photoinjector beamline has been designed to deliver 10-ps long electron bunches of 1 nC with a normalized projected transverse emittance smaller than 1.2 mm-mrad at 135 MeV. Tolerances and regulation requirements are tight for this tuning. Half of the total emittance at the end of the injector comes from the ''cathode emittance'' which is 0.7 mm-mrad for our nominal 1nC tuning. As the ''cathode emittance'' scales linearly with laser spot radius, the emittance will be dramatically reduced for smaller radius, but this is only possible at lower charge. In particular, for a 0.2 nC charge, we believe we can achieve an emittance closer to 0.4 mm-mrad. This working point will be easier to tune and the beam quality should be much easier to maintain than for the 1 ...

2006-03-17

475

A study into effects of CO2 laser melting of nitrided Ti-6Al-4V alloy  

Science.gov (United States)

Multiple treatment of engineering surfaces can provide improved surface properties that cannot be obtained by a single surface treatment. Consequently, this study investigates the effects of laser melting on the microstructures of plasma nitrided Ti-6Al-4V alloy. The study consists of two parts. In the first part, governing equations pertinent to the laser melting process are developed, and temperature variation across the melted zone is predicted. In the second, an experiment is conducted to nitride the surface of the alloy through plasma nitriding process and to melt the plasma nitrided and the untreated alloy surfaces with a CO2 laser beam. The resulting metallurgical changes are examined using x-ray diffraction (XRD), bdenergy-dispersive spectrometry (EDS), and scanning electron microscopy (SEM) techniques. It is shown that three distinct nitride layers are formed in the vicinity of the alloy surface prior to the laser melting process, and ...

1997-10-01

476

Beam Profile Measurement and its Application to Calculate Beam Emittance Using Wire Scanner for the PEFP 20MeV linac  

International Nuclear Information System (INIS)

A 20-MeV proton accelerator is developed by Proton Engineering Frontier Project (PEFP) at Korea Atomic Energy Research Institute (KAERI). The 20MeV accelerator consists of 50keV proton injector, 3MeV RFQ (Radio frequency Quadrupole), 20MeV DTL (Drift Tube Linac) and 20MeV beam line. The beam profile was measured at the end of the 20MeV beam line with wire scanner. Moreover the beam emittance was calculated from the quad scan method using beam line quadrupole magnets. In this paper, the beam profile measurement results are presented and the emittance measurement from the quad scan method is discussed

2010-10-01

477

A beam funnelling demonstration: Experiment and simulation  

Energy Technology Data Exchange (ETDEWEB)

Accelerator concepts for heavy-ion fusion require small emittance, high-current beams. Such applications could include funnels in which high-current, like-charged particle beams are interlaced to double beam current while retaining small emittances. The first experimental demonstration confirming the beam dynamics of the funnel principle was recently completed at Los Alamos National Laboratory. A single-leg prototype 5-MeV, H{sup {minus}} funnel was successfully tested. This single-beam demonstration explored physics issues of a two-beam funnel. It contained elements for emittance control, position control, and rf deflection, as well as diagnostics for measurement of beam intensity, position and angle centroids, energy and phase centroids, and transverse and longitudinal phase-space distributions. Results of the ...

1990-01-01

478

The Cross-Calibration of Swift-BAT and Fermi-GBM via Correlative Spectral Analysis of GRBs  

CERN Document Server

We report on recent inter-calibration studies featuring Swift's Burst Alert Telescope (BAT) and Fermi's Gamma-ray Burst Monitor (GBM) based upon correlated observations of GRBs 080804 and 080810, via their resultant joint spectral analysis. Swift's intrinsic multi-wavelength instrumentation and dynamical response complement Fermi's superior energy range. The addition of BAT's spectral response will (i) facilitate in-orbit GBM detector response calibration, (ii) augment Fermi's low energy sensitivity, (iii) enable ground-based follow-up efforts of Fermi GRBs, and (iv) help identify a subset of GRBs discovered via off-line GBM data analysis, for an annual estimate of ~30 GRBs. The synergy of BAT and GBM augments previous successful joint spectral fit efforts by enabling the study of peak photon energies (Epeak), while leveraging the over eleven energy decades afforded by Fermi's Large Area Telescope ...

2009-01-01

479

X-ray and UV-light irradiation effects on oxide superconducting thin films  

International Nuclear Information System (INIS)

Oxide superconducting thin films were irradiated with X-rays and ultra-violet (UV) light, and induced radiation effects on electrical and chemical properties were examined by transport measurement, X-ray diffraction analysis (XRD), diamagnetization measurement and X-ray photoemission spectroscopy (XPS). After irradiation for ErBa_2Cu_3O_x films with X-rays emitted from a Rh tube for 100 hours, superconductivity was remarkably damaged, destroying the zero-resistance state. The UV-light irradiation for Bi_2Sr_2CaCu_2O_x films was performed in He gas of about 500 Pa with a low pressure mercury lamp. The superconductivity was gradually degraded with the UV irradiation time up to 70 minutes. In both cases, adequate oxygen-annealing treatments restored superconductivity. The X-ray photoemission spectra showed that the mean Cu valence of the films was decreased approximately from +2 to +1 ...

480

Portable fluid X-ray diagnostic system  

Energy Technology Data Exchange (ETDEWEB)

A portable X-ray image system is described comprising: (a) a base assembly including panels and hinges joining the panels together along edges, and compression stops for biasing the hinges to compensate for the weight of payload when mounted on the base assembly, the compression stops being located for interaction with the hinges for biasing the panels to exhibit upward bowing when laid upon a flat surface prior to loading, and to provide resiliency for facilitating the base assembly assuming a substantially flat configuration when a predetermined payload is placed upon the base assembly; (b) an X-ray member; (c) apparatus for detachably mounting a table member to the base assembly to hold the table member at a location above the base; (d) an X-ray source; (e) means for sensing X-rays to form an image; (f) means for mounting the X-ray source and the X-ray ...

1989-02-14

481

Hard X-ray identification of Eta Carinae and steadiness close to periastron  

CERN Document Server

Context: The colliding-wind binary Eta Car exhibits soft X-ray thermal emission that varies strongly around periastron, and non-thermal emission seen in hard X-rays and gamma-rays. Aims: To definitively identify Eta Car as the source of the hard X-ray emission, to examine how changes in the 2-10 keV band influence changes in the hard X-ray band, and to understand more clearly the mechanisms producing the non-thermal emission using new INTEGRAL observations obtained close to periastron. Methods: A Chandra observation encompassing the ISGRI error circle was analysed, and all other soft X-ray sources (including the outer shell of Eta Car itself) were discarded as likely counter-parts. New hard X-ray images of Eta Car were studied close to periastron, and compared to previous observations far from periastron. Results: The INTEGRAL component, when represented by a ...

2010-01-01

482

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two detectors, respectively ...

2007-01-01

483

DETECTION OF AN X-RAY PULSATION FOR THE GAMMA-RAY PULSAR CENTERED IN CTA 1  

International Nuclear Information System (INIS)

We report the detection of X-ray pulsations with a period of ?315.87 ms from the 2009 XMM-Newton observation for the radio-quiet ?-ray pulsar, LAT PSR J0007+7303, centered in the supernova remnant CTA 1. The detected pulsed period is consistent with the ?-ray periodicity at the same epoch found with the Fermi Gamma-ray Space Telescope. The broader sinusoidal structure in the folded light curve of the X-ray emission is dissimilar to that of the ?-ray emission, and the phase of the peak is about 0.5 shifting from the peak in the ?-ray bands, indicating that the main component of the X-rays originates from different sites of the pulsar. We conclude that the main component of the X-ray pulsation is contributed by the thermal emission from the neutron star. Although with a significantly different characteristic age, PSR J0007+7303 is similar to Geminga in emission properties of X-rays ...

2010-12-10

484

Application of imaging plate technology for NDT; Imaging plate gijutsu to sono oyo  

Energy Technology Data Exchange (ETDEWEB)

This paper describes Fuji computed radiography (FCR) of Fuji Film for NDT (non-destructive testing). Imaging plate (IP) is a two-dimensional detector of X-ray, and shows higher photographic sensitivity than X-ray film. The output emission of IP provides a good linear relationship to X-ray intensity in a wide intensity range. When this emission can be digitized, the X-ray intensity can be also digitized. IP is applied to NDT as an inspection using X-ray. FCR provides higher photographic sensitivity than the conventional X-ray film method, which results in one-fifth to one-twentieth of irradiation time. Images with stable density can be obtained independent of the intensity. Since IP has a wide dynamic range, the variation of X-ray intensity of 1:500 can be expressed in a single image by single shot. High density record including 1000 images ...

1998-10-01

485

A Remarkable Low-Mass X-ray Binary within 0.1 pc of the Galactic Center  

CERN Document Server

Recent X-ray and radio observations have identified a transient low-mass X-ray binary (LMXB) located only 0.1 pc in projection from the Galactic center, CXOGC J174540.0-290031. In this paper, we report the detailed analysis of X-ray and infrared observations of the transient and its surroundings. Chandra bservations detect the source at a flux of F_X = 2e-12 erg cm^-2 s^-1 (2-8 keV). After accounting for absorption both in the interstellar medium and in material local to the source, the implied luminosity of the source is only L_X = 4e34 erg/s (2-8 keV; D=8 kpc). However, the diffuse X-ray emission near the source also brightened by a factor of 2. The enhanced diffuse X-ray emission lies on top of a known ridge of dust and ionized gas that is visible infrared images. We interpret the X-ray emission as scattered flux from the outburst, and determine that the peak ...

2005-01-01

486

Trace element analysis and speciation for coal combustion systems using secondary ion mass spectrometry (SIMS) and particle induced x-ray emissions (PIXE)  

International Nuclear Information System (INIS)

Coal is the most abundant available fossil fuel in Australia and provides a substantial part of energy needs. It is used for power generation, to supply energy to industry as well as for domestic requirements. Analysis of trace elements (the elements present in coal in ppm/ppb level) during combustion of coal in very important. Trace elements, like heavy metals such as arsenic, selenium, and chromium etc. are hazardous to the environment and some of them have carcinogenic potency. In the near future more stringent limits may be proposed for such elements generated from combustion process, such as coal combustion in power plants. Hence analysis and assessment of the emissions of these elements is essential at this stage. The first step towards reducing any impacts of trace elements is to have accurate quantitative analysis. Analysis of coal, bottom ash and fly ash collected from five different power stations across Australia was carried out to ...

2005-11-20

487

Plasma dynamics in PF-1000 device under full-scale energy storage: I. Pinch dynamics, shock-wave diffraction, and inertial electrode  

International Nuclear Information System (INIS)

This paper (paper I) presents the first part of results obtained with the PF-1000 facility for the first time at its upper energy limit (?1 MJ). Special attention is paid here to plasma ('pinch') dynamics, which was investigated in relation to its electro-technical and radiation (especially neutron) characteristics with the help of a number of diagnostics, both time-integrated and with nanosecond temporal resolution. In these methods we utilized a Rogowski coil for the routine electro-technical measurements, visual multi-frame and streak cameras, soft x-ray pin-hole multi-frame cameras, PIN-diode assembly and PM tubes with scintillators for soft and hard x-rays as well as for neutron investigations together with a set of activation counters. In particular, the temporal cross correlation of different phenomena taking place during the discharge was investigated. The pinch's longevity appears to be 10-15 times larger than the ...

2007-04-07

488

Automated ARXPS goniometer/diffractometer. Final report, April 1995--March 1997  

Energy Technology Data Exchange (ETDEWEB)

This award provided for an automated computer-controlled goniometer/diffractometer/manipulator with hot and cold stages and data acquisition system that was interfaced with the high resolution Scienta ESCA-300 X-ray photoelectron spectrometer at Lehigh University. The automation allows angular dependent X-ray photoelectron spectroscopy (XPS) and ultraviolet photoelectron spectroscopy (UPS) data to be accurately and rapidly collected without the very time-consuming and labor-intensive manual method that was previously required. It also provides for automated multi-sample analyses, collecting both wide survey scans and selected binding energy range analyses, with complete computer control and data storage. This allows 24 hour data collection without requiring the continuous presence of operators. The overall result is a greater productivity for the XPS laboratory, approximately doubling the output of the laboratory. While the ...

1998-07-01

489

Results from a Prototype Chicane-Based Energy Spectrometer for a Linear Collider  

Energy Technology Data Exchange (ETDEWEB)

The International Linear Collider (ILC) and other proposed high energy e{sup +}e{sup -} machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 10{sup -4}. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006-2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5 {center_dot} 10{sup -4} was measured, which is satisfactory for most scenarios. We also report on the ...

2011-02-28

490

Instrumentation and Controls Division progress report, September 1, 1980-July 1, 1982  

Energy Technology Data Exchange (ETDEWEB)

Activities are reported by the Reactor Systems Section, Research Instrument Section, and the Measurement and Controls Engineering Section. Reactor system activities include dynamic analysis, survillanc and diagnostic methods, design and evaluation, detectors, facilities support, process instrumentation development, and special assignments. Activities in the Research Instrument Section include the Navy-ORNL RADIAC development program, advanced ..gamma.. and x ray detector systems, neutron detection and subcriticality measurements, circuit development, position-sensitive detectors, stand-alone computers, environmental monitoring-detectors and systems, plant security, engineering support for fusion energy division, engineering support for accelerator physics, and communications: radio, closed-circuit tv, and computer. Activities in the Measurement and Controls Engineering Section include the AVLIS program; gas centrifuge ...

1982-12-01

491

Improved adhesion for thermoplastic polymers using oxyfluorination  

Energy Technology Data Exchange (ETDEWEB)

Industrial applications of thermoplastic polymers are often limited by their poor adhesion properties. In this work the effect of surface oxyfluorination on the adhesion properties was investigated for polyethylene (PE), polyoxymethylene (POM), polybutylene terephthalate (PBT) and polyamide 6 (PA6). The adhesive joint strength was quantified using lap-shear tests. These results were correlated with the changes in the chemical composition of the surface, determined by X-ray photoelectron spectroscopy (XPS), in the surface free energy, measured by the contact angle method, and in the topography, using white-light confocal microscopy. The adhesive strength is strongly improved for all four polymers, but the degree of this increase depends on the polymer type. The surface free energy shows a similar trend for all four polymers. A high surface free energy exceeding 50 mN/m was observed after ...

2008-03-15

492

Evolution of defect structures during cold rolling of ultrafine-grained Cu and Cu-Zn alloys: Influence of stacking fault energy  

Energy Technology Data Exchange (ETDEWEB)

Samples of pure Cu, bronze (Cu-10 wt.% Zn) and brass (Cu-30 wt.% Zn) with stacking fault energies (SFE) of 78, 35, and 14 mJ/m{sup 2}, respectively, were processed by high-pressure torsion (HPT) and by a combination of HPT followed by cold-rolling (CR). X-ray diffraction measurements indicate that a decrease in SFE leads both to a decrease in crystallite size and to increases in microstrain, dislocation and twin densities for the HPT and HPT + CR processed ultrafine-grained (UFG) samples. Compared with processing by HPT, subsequent processing by CR refines the crystallite size of all samples, increases the twin densities of UFG bronze and brass, and increases the dislocation density in UFG bronze. It also decreases the dislocation density in UFG brass and leads to an unchanged dislocation density in UFG copper. The results suggest there may be an optimum stacking fault energy for dislocation accumulation in UFG Cu-Zn alloys ...

2008-02-15

493

Constraining the Dark Energy Equation of State using Alternative High-z Cosmic Tracers  

CERN Document Server

We propose to use alternative cosmic tracers to measure the dark energy equation of state and the matter content of the Universe [w(z) & Omega_m]. Our proposed method consists of two components: (a) tracing the Hubble relation using HII galaxies which can be detected up to very large redshifts, z~4, as an alternative to supernovae type Ia, and (b) measuring the clustering pattern of X-ray selected AGN at a median redshift of z~1. Each component of the method can in itself provide interesting constraints on the cosmological parameters, especially under our anticipation that we will reduce the corresponding random and systematic errors significantly. However, by joining their likelihood functions we will be able to put stringent cosmological constraints and break the known degeneracies between the dark energy equation of state (whether it is constant or variable) and the matter content of the universe and provide a ...

2009-01-01

494

Alternative High-z Cosmic Tracers and the Dark Energy Equation of State  

CERN Document Server

We propose to use alternative cosmic tracers to measure the dark energy equation of state and the matter content of the Universe [w(z) & \\Omega_m]. Our proposed method consists of two components: (a) tracing the Hubble relation using HII-like starburst galaxies, as an alternative to SNIa, which can be detected up to very large redshifts, z~4, and (b) measuring the clustering pattern of X-ray selected AGN at a median redshift of ~1. Each component of the method can in itself provide interesting constraints on the cosmological parameters, especially under our anticipation that we will reduce the corresponding random and systematic errors significantly. However, by joining their likelihood functions we will be able to put stringent cosmological constraints and break the known degeneracies between the dark energy equation of state (whether it is constant or variable) and the matter content of the universe and provide a ...

2009-01-01

495

Polarizing a stored proton beam by spin flip?  

International Nuclear Information System (INIS)

We discuss polarizing a proton beam in a storage ring, either by selective removal or by spin flip of the stored ions. Prompted by recent, conflicting calculations, we have carried out a measurement of the spin-flip cross section in low-energy electron-proton scattering. The experiment uses the cooling electron beam at COSY as an electron target. The measured cross sections are too small for making spin flip a viable tool in polarizing a stored beam. This invalidates a recent proposal to use co-moving polarized positrons to polarize a stored antiproton beam.

2009-04-27