A method has been developed to optimize the energy resolution of a horizontally focusing monochromator. The method consists of determining the optimum radius of curvature of the cylindrically bent monochromator crystal by minimizing the total diffracted X-ray flux measured through an X-rayabsorption foil. When measured at an absorption edge a global minimum can be identified, which corresponds to the minimum energy band accepted along the entire length of the crystal. Experimental verification of this method has been validated by comparing X-ray fluorescent scans taken for a series of crystal curvatures and by directly measuring the X-ray beam profiles at the corresponding points. The actual optical configuration and asymmetric-cut parameter of the focusing monochromator on beamline X4C at the ...
An numerical method was developed for measuring radiant temperature using a set of absorption-foils coupled to soft xray streak camera, SXRSC, in laser plasma experiments. An numerical code, SCC, was given. An x-ray intensity ratio vs temperature was calculated for Parylene, C_3H_6, Mylar and Aluminium. A suitable range of the measuring temperature was discussed to some absorber.
The Warm-Hot Intergalactic Medium (WHIM) arises from shock-heated gas collapsing in large-scale filaments and probably harbours a substantial fraction of the baryons in the local Universe. Absorption-line measurements in the ultraviolet (UV) and in the X-ray band currently represent the best method to study the WHIM at low redshifts. We here describe the physical properties of the WHIM and the concepts behind WHIM absorption line measurements of H I and high ions such as O VI, O VII, and O VIII in the far-ultraviolet and X-ray band. We review results of recent WHIM absorption line studies carried out with UV and X-ray satellites such as FUSE, HST, Chandra, and XMM-Newton and discuss their implications for our knowledge of the WHIM.
An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.
The radionuclide X-ray fluorescence and particle induced X-ray emission methods were used for rapid and nondestructive analysis of metallic glasses. The methods were compared for accuracy and precision with the atomic absorptionmethod. Some results of the analyses of Fe_xNi_8_0_-_xB_2_0 materials are briefly reviewed. The distribution of elements along the width as well as the length and a qualitative analysis of the composition of material surfaces are considered. (author).
Radionuclide X-ray fluorescence and particle induced X-ray emission methods were used for a rapid and nondestructive analysis of metallic glasses. The methods are compared in accuracy and precision with the atomic absorptionmethod. Some results of analyses of Fe_xNi_8_0_-_xB_2_0 materials are briefly reviewed. The distribution of elements along the width and length, and a qualitative analysis of the composition of material surfaces are considered. (author) 3 refs.
A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.
We present a sample preparation method for measuring magnesium in individual whole lymphocytes by electron probe X-ray microanalysis. We use Burkitt's lymphoma cells in culture as the test sample and compare X-ray microanalysis of individual cells with atomic absorption analysis of pooled cell populations. We determine the magnesium peak-to-local continuum X-ray intensity ratio by electron probe X-ray microanalysis and calculate a mean cell magnesium concentration of 39 +/- 19 mmol/kg dry weight from analysis of 100 cells. We determine a mean cell magnesium concentration of 34 +/- 4 mmol/kg dry weight by atomic absorption analysis of pooled cells in three cell cultures. The mean cell magnesium concentrations determined by the two methods are not significantly different. We find a 10% coefficient of variation for both ...
The X-ray photoacoustic spectra of copper and brass (64.7 wt.% Cu and 35.3 wt.% Zn) have been measured at XANES (X-rayabsorption near-edge structure) regions using synchrotron radiation. These spectra were compared with optical density of X-ray spectra. It is shown that the information derived from XANES is also included in the X-ray photoacoustic spectrum which reflects the heat production processes in copper and brass. However, the results showed that the increases and changes of the photoacoustic signal were different from those of the X-rayabsorption coefficient at XANES regions. (author).
We present a sample preparation method for measuring magnesium in individual whole lymphocytes by electron probe X-ray microanalysis. We use Burkitt's lymphoma cells in culture as the test sample and compare X-ray microanalysis of individual cells with atomic absorption analysis of pooled cell populations. We determine the magnesium peak-to-local continuum X-ray intensity ratio by electron probe X-ray microanalysis and calculate a mean cell magnesium concentration of 39 +- 19 mmol/kg dry weight from analysis of 100 cells. We determine a mean cell magnesium concentration of 34 +- 4 mmol/kg dry weight by atomic absorption analysis of pooled cells in three cell cultures. The mean cell magnesium concentrations determined by the two methods are not significantly different. We find a 10% coefficient of variation for both ...
An x-ray fluorescence spectrometer was designed and fabricated which nondestructively determines the thickness of aluminum cladding at small suspected thin spots in the inner or outer surface of actinide reactor tubes. The analysis method is based on the difference in absorption of actinide L/sub #alpha#/ and L/sub #beta#/ fluorescent x-rays in passing through the cladding. Calibration plots of the logarithm of the L/sub #beta#//L/sub #alpha#/ x-ray intensity ratio versus cladding thickness are linear to at least 40 mils for U-Al, U_3O_8-Al, and PuO_2-Al substrates. Accuracy and precision of the experimentally determined cladding thickness and evaluated for both uranium and plutonium substrates. Experimental thickness data are reported for 618 quality assurance analyses on six Mark 41 PuO_2-Al target tubes. An x-ray fluorescence cladding thickness monitor ...
We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.
Measurements on laser shock compressed aluminium using the EXAFS (Extended X-rayAbsorption Fine Structure) technique on the Al K-edge are described. Two methods of analysis of this data were used for the determination of density: the standard EXAFS technique using Fourier transforms and curve fitting, and a method based on a bandstructure calculation of the absorption spectra as a function of compression. These two techniques give results which are in fairly good agreement with each other and also with a hydrodynamic simulation of the experiment. The ion correlation parameter is estimated and shows that two-sided laser irradiation of aluminium foils produces a dense plasma which is strongly coupled. (author).
A novel single-step synthetic method for the preparation of anatase N-doped TiO"2 nanocrystalline at low temperature has been devoleped. The N-doped anatase TiO"2 nanoparticles were synthesized by sonication of the solution of tetraisopropyl titanium and urea in water and isopropyl alcohol at 80^oC for 150min. The as-prepared sample was characterized by X-ray diffraction, transmission electron microscopy, X-ray photoelectron spectroscopy and UV-vis absorption spectrum. The product structure depends on the reaction temperature and reaction time. The photocatalytic activity of the as-prepared photocatalyst was evaluated via the photodegradation of an azo dye direct sky blue 5B. The results show that the N-doped TiO"2 nanocrystalline prepared via sonication exhibit an excellent photocatalytic...
The use of the ratio of the characteristic intensity to the continuum background intensity (P/B ratio) of the X-ray spectrum for a quantitative ion microprobe (IMP) or PIXE (particle induced X-ray emission) analysis of thin biological specimens was proposed previously. The IMP analysis of thick biological specimens is also of considerable practical use. In this paper, the possibility of using the P/B ratio to quantify minor elements in thick biological specimens is investigated. The epoxy resin based standards with gradual concentrations of KCNS up to 0.6 mol/kg and NBS bovine liver were analyzed by a 27 MeV {alpha} particle microprobe. The measured peak to background ratios (between 4.4 to 5.7 keV) agreed well with the theoretical calculations. The calculations showed that the concentration dependence of the P/B ratios was determined mainly by the absorption of X-rays in specimens. The results indicate ...
We have performed extended X-rayabsorption fine structure (EXAFS) analysis for artificial Cr-goethite to elucidate the local structure around Cr in Cr-goethite. The spectra were obtained using synchrotron radiation X-rays at the Photon Factory in Tsukuba. The first shell contributions were isolated by Fourier filtering EXAFS data, and the inverse Fourier transformed single-shell data were analyzed using a curve fitting method. The results show that Cr is coordinated with (7#+-#1)O"2"- ions. The protective characteristics of the Cr-goethite protective rust layer on weathering steel can be interpreted in terms of the O"2"- coordination around Cr"3"+ resulting in the creation of negative fixed charge in the Cr-goethite particles. (author)
Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A /sup 238/Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed.
We analyze archived Chandra and XMM-Newton X-ray observations of 536 Sloan Digital Sky Survey (SDSS) Data Release 5 (DR5) quasars (QSOs) at 1.7 <= z <= 2.7 in order to characterize the relative UV and X-ray spectral properties of QSOs that do not have broad UV absorption lines (BALs). We constrain the fraction of X-ray weak, non-BAL QSOs and find that such objects are rare; for example, sources underluminous by a factor of 10 comprise $\\la$2% of optically-selected SDSS QSOs. X-ray luminosities vary with respect to UV emission by a factor of $\\la$2 over several years for most sources. UV continuum reddening and the presence of narrow-line absorbing systems are not strongly associated with X-ray weakness in our sample. X-ray brightness is significantly correlated with UV emission line properties, so that relatively ...
The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K{sub {alpha}} X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K{sub {alpha}} X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions ...
The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K_#alpha# X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K_#alpha# X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be ...
We describe a method of determining the system parameters in non-eclipsing interacting binaries. We find that the extent to which an observer sees the shape of the Roche-lobe of the secondary star governs the amount of distortion of the absorption line profiles. The width and degree of asymmetry of the phase-resolved absorption line profiles show a characteristic shape, which depends primarily on the binary inclination and gravity darkening exponent. We show that, in principle, by obtaining high spectral and time resolution spectra of quiescent cataclysmic variables or low mass X-ray binaries in which the mass-losing star is visible, fitting the shape of absorption line profiles will allow one to determine not only the mass function of the binary, but also the binary inclination and hence the mass of the binary components.
X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging
The local environment of Ca dopants in barium titanate, BaTiO_3, is investigated by Ca K-edge X-rayabsorption near-edge structure (XANES) spectroscopy. In conjunction with experiments, first-principles calculations by two methods are systematically made. The projector-augmented wave (PAW) method is used to optimize the local structure and obtain the formation energy. The augmented plane wave plus local orbitals method is adopted to obtain theoretical XANES spectra. A comparison between experimental and theoretical XANES spectra shows that Ca dopants are located at the Ba"2"+ sites forming Ca"2"+. Formation energy calculations of Ca doped BaTiO_3 by the PAW method also give the same results. The Ca atom in BaTiO_3 is off-centering in comparison with the Ba site in BaTiO_3. The off-centering of Ca atom is newly revealed by the combination of XANES spectroscopy ...
Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)
X-ray scattering methods suitable for the investigation of the morphology and chemical composition of self-organized quantum dots and quantum wires are reviewed. Their application is demonstrated in experimental examples showing that a combination of small angle X-ray scattering with high-resolution X-ray diffraction can reveal both the shape and the chemical composition of the self-organized objects. (author)
Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A "2"3"8Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed. (author).
Extended X-rayabsorption fine structure (EXAFS) measurements of bismuth clusters in the temperature range of 23 -300 K have been performed using synchrotron radiation in order to investigate the size dependent phase transition. The inter-atomic distances around 3.0 A and 3.6 A are attributed to the nearest neighbors within the layer and between layers, respectively. EXAFS functions were analysed by the curve fitting method within a symmetric distribution approximation. The nearest neighbor distance of the 0.5 nm thick films is shorter than that of the 300 nm thick films at all the temperatures, which is related to the reduction of the inter-layer correlation.
The method of augmented plane wave (APW) is used to obtain the band structure of the SmS compound in the semiconductor and metal phases. The noncentral part of the Coulomb electron-electron interaction is taken into account in the first order perturbation theory. In this case the radial part of the wave APW-function is taken as a zero approximation function. A multiplet structure of the excited configuration f"5d, which provides a good description of the X-ray photoelectron spectrum and optical spectrum epsilon_2(#omega#), is obtained. The configuration fd is calculated for the interpretation of the optical absorption spectrum of the samarium monosulfide metal phase. (author).
The author's achievements in the title field are summarized and discussed. The following topics are dealt with: (i) principles of radionuclide X-ray fluorescence analysis; (ii) mathematical methods in X-ray fluorescence analysis; (iii) Ross differential filters; (iv) application of radionuclide X-ray fluorescence analysis in the coal industry (with emphasis on the determination of the ash content, sulfur content, and arsenic content of coal); and (v) evaluation of the X-ray fluorescence analyzer from the radiological safety point of view. (P.A.).
Discusses methods for determining ash content in coal using backscattering in X-ray fluorescence. The following aspects are evaluated: principle of ash content determination, energy sources, factors that influence measurement accuracy, reliability. Types of X-ray fluorescence analyzers developed in Czechoslovakia and manufactured in the Czech Republic are comparatively evaluated. Operation of the RPM 113.1 radionuclide X-ray fluorescence analyzer developed by the PAR company and used for measuring ash content in coal and coal calorific value is discussed. 7 refs.
The development of new efficient afterglow phosphors is currently hampered by a limited understanding of the persistent luminescence mechanism. Radioluminescence (RL) and x-rayabsorption measurements on the persistent phosphor SrAl2O4:Eu,Dy were combined to reveal possible valence state changes for the rare earth (co)dopants. Traps in the phosphor material are quickly filled when exposing thermally emptied SrAl2O4:Eu,Dy powder to xrays. On the same time scale a partial oxidation of Eu2+ to Eu3+ is observed by x-rayabsorption near-edge spectroscopy (XANES), while for the trivalent dysprosium the valence state remains unchanged. The impact of these observations on the recently proposed models for persistent luminescence is discussed.
We present the X-ray properties of a sample of 17 radio sources observed with the Chandra X-ray Observatory as part of a project aimed at studying the X-ray emission from their radio jets. In this paper, we concentrate on the X-ray properties of the unresolved cores. The sample includes 16 quasars (11 core-dominated and 5 lobe-dominated) in the redshift range z=0.30--1.96, and one low-power radio-galaxy at z=0.064. No diffuse X-ray emission is present around the cores of the quasars, except for the nearby low-power galaxy that has diffuse emission on a scale and with a luminosity consistent with other FRIs. No high-amplitude, short-term variability is detected within the relatively short Chandra exposures. However, 1510-089 shows low-amplitude flux changes with a timescale of $\\sim$25 minutes. The X-ray spectra of the quasar cores are generally well described ...
Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.
A photon-induced x-ray fluorescence method allowing the simultaneous determination of iron, copper, zinc, bromine and rubidium in human blood and blood plasma samples is described. The method is reliable and has a good sensitivity for a wide range of elements. (author).
Sulfur K-edge X-rayabsorption spectroscopy is a powerful in situ probe of sulfur biochemistry in intact cells and tissues. Under favorable circumstances the technique can provide quantitative information on the chemical identify of the sulfur species that are present in a sample. Prange et al. have recently reported an X-rayabsorption spectroscopic study of bacterial sulfur storage globules. Unfortunately there are substantial problems with the experimental technique employed that, they contend, lead to completely erroneous conclusions. In the more recent of their two papers Prange et al. employed a curve-fitting method similar to that used by us (for more than 10 years). In essence, the method employs simply fitting a linear combination of the spectra of standard compounds to that of the unknown, in this case cultures of bacterial cells. This type of analysis ...
We obtain x-rayabsorption near-edge structures (XANES) by solving the equation of motion for the two-particle Green's function for the electron-hole pair, the Bethe-Salpeter equation (BSE), within the all-electron full-potential linearized augmented plane wave method (FPLAPW). The excited states are calculated for the Li K-edge in the insulating solids LiF, Li_2O and Li_2S, and absorption spectra are compared with independent particle results using the random phase approximation (RPA), as well as supercell calculations using the core-hole approximation within density functional theory (DFT). The binding energies of strongly bound excitations are determined in the materials, and core-exciton wavefunctions are demonstrated for LiF.
Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a ...
The X-ray intensity ratio K_#beta#/K_#alpha# has been measured by using a 10 mCi "5"5Fe source (Mn K X-rays) and high resolution Si(Li) detector system coupled to a computer-controlled multichannel analyzer over the range of 15#<=#Z#<=#22. Correction have been made to the measured relative intensities (K_#alpha# and K_#beta# X-rays) for self-absorption in the sample, air, Be-window absorption and detection efficiency. The results are compared with those of other experiments and with the Scofield calculations. (author) 13 refs.; 3 figs.; 2 tabs.
Microanalytical methods suitable for the determination of Fe, Cu in HT-29 (human colon adenocarcinoma) cells treated with different iron compounds (Fe(II) sulfate, Fe(III) chloride, Fe(III) citrate and Fe(III) transferrin) and cultured in medium supplemented or not with 10% (v/v) fetal calf serum (FCS) by total reflection X-ray fluorescence spectrometry (TXRF) and simultaneous graphite furnace atomic absorption spectrometry (GF-AAS) were developed. The developed TXRF method was also suitable for Zn determination in the samples. The main advantage of the proposed methods is the execution of all sample preparation steps following incubation and prior to the elemental analysis in the same Eppendorf tubes. Sample preparation was performed at microscale (115mL sample volume) with 65% nitric aci...
TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. ...
In this paper, we report a method of precise in situ x-ray scattering measurements on protein solutions using small stationary sample cells. Although reduction in the radiation damage...Full Text Available
Bi-U mixed oxides were synthesized by two methods and characterized by X-ray diffraction and X-ray photoelectron spectroscopy. The samples were tested for the catalytic oxidation of carbon monoxide by oxygen. A stepwise redox mechanism consistent with the kinetic results is proposed. (orig.).
Recent X-ray and radio observations have identified a transient low-mass X-ray binary (LMXB) located only 0.1 pc in projection from the Galactic center, CXOGC J174540.0-290031. In this paper, we report the detailed analysis of X-ray and infrared observations of the transient and its surroundings. Chandra bservations detect the source at a flux of F_X = 2e-12 erg cm^-2 s^-1 (2-8 keV). After accounting for absorption both in the interstellar medium and in material local to the source, the implied luminosity of the source is only L_X = 4e34 erg/s (2-8 keV; D=8 kpc). However, the diffuse X-ray emission near the source also brightened by a factor of 2. The enhanced diffuse X-ray emission lies on top of a known ridge of dust and ionized gas that is visible infrared images. We interpret the X-ray emission as scattered flux from the outburst, and ...
The effect of anode length and operating gas pressure on the x-ray emission from a nitrogen-filling modified plasma focus device has been investigated. The time-resolved investigation of xray was carried out by using a five-channel photodiode x-ray spectrometer. The maximum x-ray yield is seen to increase with the increase in the anode length from 110 to 125 mm. Further increase in the anode length to 130 mm causes the x-ray yields to decrease. The highest x-ray yield of 4.5 J into 4#pi# sr was found for 125 mm anode length, which is 0.2% of the input energy. The average x-ray photon energy was estimated by using half-value thickness method and found to be 8.4 keV. The electron temperature of the plasma was estimated to be around 3 keV by x-ray intensity ratio ...
The physical foundations are described of radionuclide X-ray fluorescence analysis (RXFA) and the table shows the values of K- and L-absorption thresholds and the K- and L-line energies of elements. The calculation of the intensity of characteristic radiation during RXFA proceeds from relations derived for conventional X-ray fluorescence analysis. The choice of the radionuclide source is ruled by the nature of the analysed substance and the used detection technique. The diagram shows the areas of radionuclide sources and the energy of the fluorescence radiation of elements. The table shows the spectra of radionuclide sources suitable for the purposes of RXFA measured by semiconductor Si(Li) and Ge(Li) detectors. (ES).
Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).
The basic principles of determination of the ash content of coal by the title methods are outlined. A brief technical characteristic of the ash meters and radionuclide X-ray fluorescence analyzers manufactured by the PAR company is presented. (Z.S.). 4 figs., 7 refs.
Determination of Mn, Fe, Ni, Cu, Zn, and Pb in human soft tissues by radionuclide X-ray fluorescence analysis (using "2"3"8Pu and "1"0"9Cd sources) is described. The results of multielement XRS analysis of selected human tissues are tabulated. They are in good agreement with the literature data. It is concluded that X-ray fluorescence technique is a suitable method for trace element determination. (author).
We have measured K-edge X-rayabsorption spectra of argon in sputtered aluminum films at a synchrotron radiation facility (the Photon Factory). We found that the energy and shape of white line change when the film is annealed at 500 C and the spectrum becomes resembling that of argon implanted in silicon. From the analyses of the X-rayabsorption spectra and TEM observation we concluded that argon exists as very small atom clusters with a diameter less than 1 nm or exist as isolated atoms in the as-sputtered aluminum film, and that the size of the clusters become as big as 10 nm diameter when the film is heated. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)
Fe-doped TiO2 hollow spheres (Fe-THs) were synthesized by sol?gel process using carbon spheres as templates. The prepared samples were characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM), UV?vis diffuse reflectance spectrum (DRS), N2 adsorption?desorption isotherms, Electron paramagnetic resonance (EPR) spectroscopy and Photoluminescence emission spectroscopy (PL). UV?vis spectra showed that Fe3+ doping could extend the absorption edge to the visible region. EPR spectra showed that Fe3+ was incorporated into the crystal lattice of TiO2, which could inhibit the recombination of photo-induced electron?hole pairs and improve the photocatalytic activity. The photocatalytic activities of the prepared samples were evaluated for the degradation of dye Reactive Brillia...
Lead is known to enter substitutionally in divalent state when doped in alkali halides. When irradiated at room temperature these lead centers (Pb"+"+) act as traps for electrons knocked off from the halogen ions and become Pb"+ and Pb"0 (for large doses of irradiation). These changes could be followed in the optical absorption studies. These lead-doped crystals after X-ray irradiation yield a thermoluminescence output smaller than that observed in 'pure' crystals. However, two new glow peaks are observed in additions to those due to F-centers. In KCl : Pb and Kbr : Pb crystals part of the F-center glow preceds the new glow peaks. The new peaks are attributed to the Pb"+ and Pb"0 centers. The glow peak temperatures and trap depths for these peaks an obtained by total-curve fitting method are reported. (author).
The ball-milling method was used to produce Mg-50 wt.% ZrFe{sub 1.4}Cr{sub 0.6} composite. The thermodynamic, kinetic, and cycling properties, as well as the resistance to oxidation were examined. This composite possesses excellent kinetic properties, even at moderate temperature. Scanning electron microscopy, energy-dispersive spectrum, transmission electron microscopy and X-ray diffraction were used to characterize the composite before and after hydriding. The fine ZrFe{sub 1.4}Cr{sub 0.6} particles covering Mg particles acting as a ''catalytic film'', a significant amount of imperfections and some alloy powder in the Mg matrix introduced by ball milling all contributed to the enhanced absorption/desorption rate. (orig.)
Manganese model complexes, relevant to the oxygen-evolving complex (OEC) in photosynthesis, were studied with Mn K-edge X-rayabsorption near-edge spectroscopy (XANES), Mn Kb X-ray emission spectroscopy (XES), and vibrational spectroscopy. A more detailed understanding was obtained of the influence of nuclearity, overall structure, oxidation state, and ligand environment of the Mn atoms on the spectra from these methods. This refined understanding is necessary for improving the interpretation of spectra of the OEC. Mn XANES and Kb XES were used to study a di-(mu)-oxo and a mono-(mu)-oxo di-nuclear Mn compound in the (III,III), (III,IV), and (IV,IV) oxidation states. XANES spectra show energy shifts of 0.8 - 2.2 eV for 1-electron oxidation-state changes and 0.4 - 1.8 eV for ligand-environment changes. The shifts observed for Mn XES spectra were approximately 0.21 eV for oxidation state-changes and only ...
Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of lifetime of the charge carriers with the increase of X-ray radiation dose.
We propose and analyze a novel regenerative amplifier free electron laser (FEL) to produce fully coherent x-ray pulses. The method makes use of narrow-bandwidth Bragg crystals to form an x-ray feedback loop around a relatively short undulator. Self-amplified spontaneous emission (SASE) from the leading electron bunch in a bunch train is spectrally filtered by the Bragg reflectors and is brought back to the beginning of the undulator to interact repeatedly with subsequent bunches in the bunch train. The FEL interaction with these short bunches not only amplifies the radiation intensity but also broadens its spectrum, allowing for effective transmission of the x-rays outside the crystal bandwidth. The spectral brightness of these x-ray pulses is about two to three orders of magnitude higher than that from a single-pass SASE FEL.
Context: The colliding-wind binary Eta Car exhibits soft X-ray thermal emission that varies strongly around periastron, and non-thermal emission seen in hard X-rays and gamma-rays. Aims: To definitively identify Eta Car as the source of the hard X-ray emission, to examine how changes in the 2-10 keV band influence changes in the hard X-ray band, and to understand more clearly the mechanisms producing the non-thermal emission using new INTEGRAL observations obtained close to periastron. Methods: A Chandra observation encompassing the ISGRI error circle was analysed, and all other soft X-ray sources (including the outer shell of Eta Car itself) were discarded as likely counter-parts. New hard X-ray images of Eta Car were studied close to periastron, and compared to previous observations far from periastron. Results: The INTEGRAL component, ...
This paper describes Fuji computed radiography (FCR) of Fuji Film for NDT (non-destructive testing). Imaging plate (IP) is a two-dimensional detector of X-ray, and shows higher photographic sensitivity than X-ray film. The output emission of IP provides a good linear relationship to X-ray intensity in a wide intensity range. When this emission can be digitized, the X-ray intensity can be also digitized. IP is applied to NDT as an inspection using X-ray. FCR provides higher photographic sensitivity than the conventional X-ray film method, which results in one-fifth to one-twentieth of irradiation time. Images with stable density can be obtained independent of the intensity. Since IP has a wide dynamic range, the variation of X-ray intensity of 1:500 can be expressed in a single image by single shot. High density record ...
The {ital L}{sub 2}-{ital L}{sub 3} Coster-Kronig transition probability ({ital f}{sub 23}) in Tm was measured by multiparameter {ital K} versus {ital L} x-ray coincidence techniques. The Tm xrays were obtained from a radioactive source of {sup 169}Yb and were detected with cooled germanium and silicon detectors of high-energy resolution. Corrections were applied for the contribution of {ital K}{alpha}{sub 1} xrays to the {ital K}{alpha}{sub 2} x-ray peak and for the contribution of unresolved {ital L}{eta} xrays to the {ital L}{alpha}{sub 1,2} x-ray peak. The contribution of {ital K}{alpha}{sub 1} xrays to the {ital K}{alpha}{sub 2} x-ray peak was determined solely from the results of the coincidence measurements using a ...
The {ital L}{sub 2}-{ital L}{sub 3} Coster-Kronig transition probability ({ital f}{sub 23}) in Tm was measured by multiparameter {ital K} versus {ital L} x-ray coincidence techniques. The Tm xrays were obtained from a radioactive source of {sup 169}Yb and were detected with cooled germanium and silicon detectors of high-energy resolution. Corrections were applied for the contribution of {ital K}{alpha}{sub 1} xrays to the {ital K}{alpha}{sub 2} x-ray peak and for the contribution of unresolved {ital L}{eta} xrays to the {ital L}{alpha}{sub 1,2} x-ray peak. The contribution of {ital K}{alpha}{sub 1} xrays to the {ital K}{alpha}{sub 2} x-ray peak was determined solely from the results of the coincidence measurements using a ...
The principle is described of X-ray fluorescence analysis and the manner of detecting the emitted characteristic radiation. The advantages are presented of radionuclide X-ray fluorescence analysis which consist primarily in the possibility of conducting a totally non-destructive analysis, and of accurate and relatively narrow localization of the analyzed area, the simultaneous qualitative and quantitative determinations of a large number of elements in the order of concentrations 10"1 to 10"-"4%, stability of excitation radiation flux, simple design and relatively low capital costs. The so-called matrix effect is pointed to. A number of examples is given of the use of the cited method, including its use in the analysis of art objects. (J.B.).
High-spatial-resolution microfocus-based X-ray imaging technology, both real-time and film, has been used to study the thickness variation that occurs in the oxide core of silver-sheathed BSCCO ribbons produced by the powder-in-tube method. This thickness variation (also called ``sausaging``) occurs during incremental rolling and degrades the critical current densities of the ribbons. Using X-ray image data the authors determined the onset and severity of sausaging. Onset occurred at a ribbon thickness of 203 {micro}m, and the severity increased with subsequent rolling reductions. Scanning electron microscopy was used to confirm the X-ray image data. X-ray imaging provides several advantages over more traditional methods for characterizing the superconductors such as optical or scanning electron microscopy. The X-ray imaging provides ...
X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw ...
X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw ...
Full text: Measurement of K_#beta# to K_#alpha# x-ray intensity ratios are important not only in the field of atomic physics, radiation physics and medical physics, but also to test the validity of assumptions made in the theoretical prediction. The intensity ratios can also give information on the effect of physical and chemical environment of the element in the compound. Many investigators have adopted a single and double reflection geometries to measure the K_#beta# to K_#alpha# xray intensity ratios to understand the effect of physical and chemical environment on x-ray fluorescence. The targets are excited by a radioactive source of having activity of the order 100 MBq. in order to carry out accurate measurement K_#beta# to K_#alpha# x-ray intensity ratios, we have develop 2#pi# geometrical configuration method : placing a target right on the surface of the ...
A WO3/TiO2 composite, hollow-sphere photocatalyst with average diameter of 320nm and shell thickness of 50nm was successfully prepared using a template method. UV-vis diffuse reflectance spectra illustrated that the main absorption edges of the WO3/TiO2 hollow spheres were red-shifted compared to the TiO2 hollow spheres, indicating an extension of light absorption into the visible region of the composite photocatalyst. The WO3 and TiO2 phases were confirmed by X-ray diffraction analysis. BET isotherms revealed that the specific surface area and average pore diameter of the hollow spheres were 40.95m^2/g and 19nm, respectively. Photocatalytic experiments indicate that 78% MB was degraded by WO3/TiO2 hollow spheres under visible light within 80min. Under the same conditions, only 24% MB can ...
Using the SCUBA bolometer array on the JCMT, we have carried out a submillimetre survey of Broad Absorption Line quasars (BALQs). The sample has been chosen to match, in redshift and optical luminosity, an existing benchmark 850um sample of radio-quiet quasars, allowing a direct comparison of the submm properties of BAL quasars relative to the parent radio-quiet population. We reach a submm limit 1.5mJy at 850um, allowing a more rigorous measure of the submm properties of BAL quasars than previous studies. Our submm photometry complements extensive observations at other wavelengths, in particular X-rays with Chandra and mid-infrared with Spitzer. To compare the 850um flux distribution of BALQs with that of the non-BAL quasar benchmark sample, we employ a suite of statistical methods, including survival analysis and a novel Bayesian derivation of the underlying flux distribution. Although there are no strong grounds for ...
A convolution/superposition method is proposed for use with primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. It should be noted that the number of energy bins is usually about ten, and that the reconstructed X-ray spectra can reasonably be applied to media with a wide range of effective Z numbers, ranging from water to lead. The study was carried out for 10-MV X-ray doses in water and thorax-like phantoms with the use of open-jaw-collimated fields. The dose calculations were made separately for primary, scatter, and electron contamination dose components, for which we used two extended radiation sources: one was on the X-ray target and the other on the flattening filter. To calculate the in-air beam intensities at po...
Objective: To investigate the X-ray radiation dose patients dealt with the hepatic intervention. Methods: Thermoluminescence and tissue-equivalent anthropomorphic phantom were used to measure the X-ray radiation dose in patients dealt with the hepatic intervention in 85 patients. Results: The peak skin dose in the patients who accepted hepatic intervention was from 179.95 to 1759.00 mGy, effective dose approached 29.22 mSv (male), 29.27 mSv (female). Conclusion: Hepatic intervention is now regarded as an important therapeutic method for liver cancer. However, the patients were exposed to too much X-ray radiation during interventional procedures. Some more effective protection should be taken to decrease the X-ray radiation dose accepted by patients. (authors)
The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase imaging with respect to standard ...
The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).
The feasibility was studied of the application of radionuclide X-ray fluorescence analysis to the identification and determination of chemical elements in the air. A description of the method is presented, the main stages of the analysis are discussed (sample preparation and standards, selection of radioactive radiation sources, geometry of measurement and evaluation of results). The method is illustrated on the determination of elements Fe, Cu, Zn, Br, and Pb in air samples taken in the city of Prague. (author) 2 tabs., 2 figs., 14 refs.
Radionuclide X-ray fluorescence analysis was used for the determination of Cu, Y and Ba in very thin high-temperature superconducting films. The precision of the method is better than 3% for about 1 #mu#m thick films. The atomic emission ICP spectrometry was used to testify results of XRF analysis. An acceptable agreement of both methods was obtained. (author) 4 refs.; 2 tabs.
This volume of the monograph covers the following topics: activation analysis, non-activation interaction analysis (elastic scattering of charged particles, absorption and backscattering of beta radiation and photons, radionuclide X-ray fluorescence analysis, thermalization, scattering and absorption of neutrons, use of ionization caused by nuclear radiation, use of ionization by alpha or beta radiation for the measurement of pressure, density and flow rate of gases), and automation in radioanalytical chemistry. (P.A.).
The nanostructure Ni-doped CdO films have been prepared by sol gel spin coating method. Atomic force microscopy results indicate that the CdO films are formed from the nanoparticles and the grain size is changed with nickel content. X-ray diffraction patterns of the films indicate that the undoped and Ni-doped CdO films have polycrystalline structure with a cubic sodium chloride structure, showing two main characteristic peaks assigned to the (111) and (200) planes. The optical band gap values of undoped and Ni-doped CdO films were determined by optical absorptionmethod. The Eg values of the CdO films were found to be in the range of 2.26?2.60?eV. The Eg values of the CdO films increase with the content of Ni dopant (up to 6% Ni). It is evaluated that the optical band gap and grain size o...
Radiotherapy can be very significant as the treatment for ocular lesions, eyes need to be preserved as properly as possible on their functions and cosmetics. The application of conventional Xray therapy has been gradually abandoned as conventional Xray therapy ceased to be accepted as the general treatment for malignant tumors. Consequently the necessity of electron beam therapy has been rising even as the substituted method for conventional Xray therapy. The department of radiology of Gunma University was obliged to establish a new therapy for ocular lesions, and has been trying electron beam therapy since 1973. It is concluded that electron beam therapy is not at all inferior to conventional Xray therapy as reported above. Basic therapeutic methods for ocular lesions are ...
The applicability of two nuclear analytical methods: radionuclide X-ray fluorescence analysis and radiometric titrations based on precipitate formations was studied in order to determine the heptacaine hydrochloride in solutions. The applied methods were evaluated based on the obtained sensitivity values.
The applicability of two nuclear analytical methods: radionuclide X-ray fluorescence analysis and radiometric titrations based on precipitate formations was studied in order to determine the heptacaine hydrochloride in solutions. The applied methods were evaluated based on the obtained sensitivity values. (author).
A radioactive particle was analyzed to discover the composition of the inactive material of the particle. The method uses the x-ray line spectrum of the K series caused by electron irradiation of the particle in the electron microscope. Iron and aluminum or silicon (the last two could not be distinguished) were found as inactive components in the particle. (D.L.C.)
Structure of ferrite in drawn pearlitic steel containing 0.9 mass% C was investigated with X-ray diffraction technique using synchrotron radiation. In the detailed analysis of diffraction peaks of ferrite during the drawing process, it was experimentally revealed that the transformation of ferrite from bcc to bct due to the supersaturation of carbon in ferrite of heavily drawn pearlitic steel.
Structure of ferrite in drawn pearlitic steel containing 0.9 mass% C was investigated with X-ray diffraction technique using synchrotron radiation. In the detailed analysis of diffraction peaks of ferrite during the drawing process, it was experimentally revealed that the transformation of ferrite from bcc to bct due to the supersaturation of carbon in ferrite of heavily drawn pearlitic steel.
Radionuclide x-ray fluorescence method was used in the determination of Cr, Ni and other heavy metals content in wastewater of an engineering plant taken both before and after chemical treatment. Toxic effects of the wastewaters using Allium cepa root tip cells were tested. (author) 8 refs.; 2 tabs.
A radiometric method was elaborated for surface density determinations of the adhesive layer of plasters by radionuclide X-ray fluorescence using the 17.47 keV bremsstrahlung of "1"4"7Pm/Mo. The bremsstrahlung line excites the 8.63 keV characteristic K#alpha# line of Zn contained in the adhesive layer of the plaster as a filling material in the form of ZnO. In homogeneous adhesive layers the Zn content is proportional to surface density. (author).
Radionuclide x-ray fluorescence analysis was used for the determination of Y, Ba and Cu in thin high-temperature superconducting films. Atomic emission ICP spectrometry was used to estimate the precision and accuracy of analytical results. Reasonable agreement between both methods was obtained when a polynomial calibration curve was applied. (author) 4 refs.; 4 tabs.
Radionuclide X-ray fluorescence method was used for the determination of Fe and Zn in healing plants (Sage, Peppermint, Stinging, Common Agrimony, Milfoil, Ribwort, Tansy, White Dead-Nettle). "2"3"8Pu exciting source and Si/Li semiconductor detector were used for the determination. (author)
Radionuclide X-ray fluorescence method with Si/Li semiconductor detector and "2"3"8Pu exciting source was used for the determination of Cu, Ni, Zn and Pb in plant samples (Taraxacum officinale) from various localities near the highway D-61 Bratislava-Trnava (SR). (author) 2 refs.; 1 fig.; 1 tab.
Radionuclide X-ray fluorescence method with Si/Li semiconductor detector and "2"3"8Pu exciting source was used for the determination of Cu, Ni, Pb, and Zn in soil samples from various localities near the D-61 Bratislava-Trnava highway (CSFR). (author) 1 ref.; 1 tab.
The possible existence of preferential B-site disorder in A-15 compounds recently claimed on the basis of x-ray powder diffraction data but questioned from the viewpoint of known phase diagrams is examined for some Nb-based compounds of this type. It is concluded that x-ray powder data do not allow the determination of both order and compositional variables as suggested, and the latter must therefore be determined by some other method. (author).
3d occupation numbers of the transition elements corresponding to various types of atomic configurations are calculated by means of the linear muffin-tin orbital (LMTO) method. This data is used with the multiconfiguration Dirac-Fock (MCDF) X-ray intensity ratios to estimate the electron populations of the 3d metals in alloys.
3d occupation numbers of the transition elements corresponding to various types of atomic configurations are calculated by means of the linear muffin-tin orbital (LMTO) method. This data is used with the multiconfiguration Dirac-Fock (MCDF) X-ray intensity ratios to estimate the electron populations of the 3d metals in alloys.
An energy dispersive x-ray fluorescence technique was used for the determination of Titanium (Ti) and Zirconium (Zr) in red mud by using a standard addition method. An annular {sup 241}Am source is employed for excitation of K shells of elements. 13 refs., 2 figs., 1 tab.
The X-ray spectra of some magnetized isolated neutron stars (NSs) show absorption features with equivalent widths (EWs) of 50 - 200 eV, whose nature is not yet well known. To explain the prominent absorption features in the soft X-ray spectra of the highly magnetized (B ~ 10^{14} G) X-ray dim isolated NSs (XDINSs), we theoretically investigate different NS local surface models, including naked condensed iron surfaces and partially ionized hydrogen model atmospheres, with semi-infinite and thin atmospheres above the condensed surface. We also developed a code for computing light curves and integral emergent spectra of magnetized neutron stars with various temperature and magnetic field distributions over the NS surface. We compare the general properties of the computed and observed light curves and integral spectra for XDINS RBS\\,1223 and conclude that the observations can be ...
Three typical Japanese coals of non-coking coal, coking coal and anthracite were heat-treated with KOH, and change in their pore structure was examined by absorption of N2, X-ray diffraction and TEM observation. In addition, the relation between a coal rank and pore structure was also studied by absorption experiment of N2. In experiment, the mixture of coal and KOH in a nickel holder was heat-treated in N2 gas flow at heating rate of 2{degree}C/min, and held at a fixed temperature for one hour. To clarify the pore structure, N2 absorption isotherms were measured at -196{degree}C under nearly 76cmHg using a commercially available full-automatic absorption measurement equipment. Based on the X-ray diffraction and TEM observation results on activated coals, the relation between the N2 absorption and pore structure was studied. The results are ...
The use of nondestructive evaluation (NDE) methods is proposed for characterization of transuranic (TRU) waste stored at the Radioactive Waste Management Complex. These NDE methods include real-time x-ray radiography, real-time neutron radiography, x-ray and neutron computed tomography, thermal imaging, container weighing, visual examination, and acoustic measurements. An integrated NDE system is proposed for characterization and certification of TRU waste destined for eventual shipment to the Waste Isolation Pilot Plant in New Mexico. Methods for automating both the classification waste and control of a complete nondestructive evaluation/nondestructive assay system are presented. Feasibility testing of the different NDE methods, including real-time x-ray radiography, and development of automated waste classification techniques are covered ...
Tl(InS_2)_1_-_x(FeSe_2)_x single crystals (where x=0; 0.001; 0.005; 0.01 and 0.015) were grown by the Bridgman-Stockbarger method. Obtained single crystals were crystallized in monoclinic structure. The present paper deals with experimental results relative to X-ray dosimetric characteristics of the Tl(InS_2)_1_-_x(FeSe_2)_x solid solutions at 300 K. Installation URS-55a was the source of radiation. X-ray radiation dose (E) falling on the crystals is measured by the crystalline X-ray dosimeter DRGZ-02. The value of X-ray conductivity coefficient K_#sigma# characterising X-ray sensitivity is defined as K_#sigma#= (#sigma#_E-#sigma#_0)/E#sigma#_0. where #sigma#_E is conductivity under the effect of X-ray radiation by intensity E, #sigma#_0 is conductivity in the lack of radiation. Comparing X-ray dosimetric characteristics ...
In order to understand the chemistry of altermetal dopants in antimony oxide, the detailed structural characterization of two ..beta..-Sb/sub 2/O/sub 4/ compounds is reported, Mo-doped ..beta..-Sb/sub 2/O/sub 4/ (1.5 metal%) and V-doped ..beta..-Sb/sub 2/O/sub 4/ (5 metal%). The methods used to characterize these materials are X-ray and neutron diffraction, scanning electron microscopy, Mo K-edge extended X-rayabsorption fine structure spectroscopy, and elemental analysis. The atomic position of each of these dopants in Sb/sub 2/O/sub 4/ is radically different as is the overall effect on the host structure. Molybdenum does not substitute for Sb atoms, rather the Mo atoms are found in channels of electron density formed by Sb/sup 3 +/ lone pairs. The two nearest Sb/sup 3 +/ are absent and the oxygen stoichiometry is preserved. The formula is Sb/sub 1.97/Mo/sub 0.015/O/sub 4/. Vanadium incorporates ...
The thickness dependent magnetic properties of artificially prepared ultrathin body-centered cubic Ni films have been explored using the all electron full potential linearized augmented plane wave (FLAPW) method. We have considered two types of BCC Ni(001) films: (i) pure BCC Ni(001) and (ii) Au capped BCC Ni(001) in the range from 1 monolayer (ML) to 4 ML of Au capping coverage. The average magnetic moment of pure BCC Ni(001) is about 0.63 #mu#_B and a typical surface enhancement is found with a magnetic moment of 0.78 #mu#_B. In the presence of an Au capping layer, the magnetic moment of interface Ni is strongly suppressed to approximately 0.5 #mu#_B and this causes a reduction of average magnetic moment. Nevertheless, the Au adlayer has no meaningful induced magnetic moment. The BCC pure Ni(001) films always have in-plane magnetization up to 11 ML, but very interestingly the Au/Ni(001) shows a thickness dependent spin reorientation transition (SRT) from in-plane ...
Using the full potential linearized augmented plane wave (FLAPW) method, the magnetic properties of two-dimensional Ru and Rh monolayers (MLs) on a NiAl(001) surface have been investigated. It has been found that free standing one monolayer Ru and Rh films have ferromagnetic ground state with magnetic moments of 2.21 and 1.48 #mu#_B, respectively. The ferromagnetism is still observed even on a Ni terminated NiAl(001) surface, while no magnetic state is found on an Al terminated surface. The calculated magnetic moments of Ru and Rh atoms are 1.56 and 0.88 #mu#_B, respectively. In addition, an induced magnetic moment in surface Ni is observed. It has been found that the free standing Ru film has perpendicular magnetization to the film surface with a magnetocrystalline anisotropy (MCA) energy of 0.66 meV/atom, while an in-plane MCA energy of 0.37 meV/atom is achieved in Rh film. Very interestingly, we find that both Ru/NiAl(001) and Rh/NiAl(001) films have ...
Hydroxyapatite samples were produced by two different wet-chemical methods, and characterized by x-ray diffraction, infrared and compression strength measurements. The x-ray diffraction measurements were simulated using the Rietveld method, and structural data as lattice parameters and average crystallite size were obtained. The infrared spectra showed the presence of CO$_3^{2-}$ ions in all samples, indicating a contamination by these ions. By mixing samples produced by both methods, a bioceramic was obtained and, after sintering, samples with very high compression strengths (26--30 MPa) were obtained.
Crystalline MnMoO{sub 4} was synthesized using a conventional solid reaction method and investigated for its physical and electrochemical properties as an anode material for Li secondary battery. The reversible amount of Li insertion/removal of MnMoO{sub 4} anode during the first cycle was about 800 mA h/g, accompanied by irreversible structural transformation into amorphous material. The amorphization during the first Li insertion was investigated by structural analysis using XRD of electrode. The charge compensation during Li insertion/removal was examined by measurement of X-rayAbsorption Near Edge Structure (XANES) spectroscopy. Despite its irreversible structural transformation to amorphous during the first lithiation, subsequent cycles showed a reasonable cyclability. This paper presents the electrochemical properties of MnMoO{sub 4} and discusses the mechanism underlying the Li insertion/removal process.
A combination of measuring instruments, consisting of a Beta-Sedimeter and a radionuclide X-ray fluorescence instrument, is described. With the Beta-Sedimeter the C-14-radiation is measured. Through direct irradiation with photons of a Pu238-source in an ancillary irradiation chamber and energy dispersing measurement of the K- and L-radiation resp. of the excited heavy metals with the aid of a Si(Li)-semiconductor detector and a 4-channel analyzer the heavy metal concentrations of the heavy metals Zn, Cr, Ni and Pb are determined. For the determination of cadmium the indirect excitation with Am-241 and Dy-targets is described. The system produces records and operates fully automatically in a step-by-step mode with a testing cycle of 45 minutes. In connection with the process monitoring of the wastewater from a zinc plating plant during a period of 8 months the concentration of the solid material and of the metals Cr and Zn, which were considered to be ...
Dye-sensitized solar cells (DSSCs) based on anatase TiO2 hollow spheres (TiO2HS)/multi-walled carbon nanotubes (CNT) nanocomposite films are prepared by a directly mechanical mixing and doctor blade method. The prepared samples are characterized by scanning electron microscopy, transmission electron microscopy, X-ray diffraction, UV-vis absorption spectroscopy and N2 adsorption-desorption isotherms. The photoelectric conversion performances of the DSSCs based on TiO2HS/CNT composite film electrodes are also compared with commercial-grade Degussa P25 TiO2 nanoparticles (P25)/CNT composite solar cells at the same film thickness. The results indicate that the photoelectric conversion efficiencies () of the TiO2HS/CNT composite DSSCs are dependent on CNT loading in the electrodes. A small amou...
Context. The high energies of protostellar jets, implied by recent observations of X-rays from such flows, came very much as a surprise. Inferred shock velocities are considerably higher than what was previously known, hence putting even larger energy demands on the driving sources of the jets. The statistics of X-ray emitting jets are still poor, yet a few cases exist which seem to imply a correlation between the presence of HeI 1.0830 mu emission and X-ray radiation in a given source. Aims. This tentative correlation needs confirmation and explanation. If the jet regions of HeI 1.0830 mu emission are closely associated with those producing X-rays, high resolution infared spectroscopy can be used to observationally study the velocity fields in the hot plasma regions of the jets. This would provide the necessary evidence to test and further develop theoretical models of intermediately fast (> 500 - ...
The resolution of X-ray diffraction microscopy is limited by the maximum dose that can be delivered prior to sample damage. In the proposed Serial Crystallography method, the damage problem is addressed by distributing the total dose over many identical hydrated macromolecules running continuously in a single-file train across a continuous X-ray beam, and resolution is then limited only by the available molecular and X-ray fluxes and molecular alignment. Orientation of the diffracting molecules is achieved by laser alignment. We evaluate the incident X-ray fluence (energy/area) required to obtain a given resolution from (1) an analytical model, giving the count rate at the maximum scattering angle for a model protein, (2) explicit simulation of diffraction patterns for a GroEL-GroES protein complex, and (3) the frequency cut off of the transfer function following iterative solution ...
Radionuclides exhibiting in decaying a strong interaction between nucleus and electron shell (especially electron capture and internal conversion) are, in principle, sensitive to their chemical surroundings. Consequently, they can be used to yield chemical information after an appropriate labelling procedure. The information can be extracted from the decay rate variation as well as from their X-ray emission as a response to an inner-shell vacancy creation during nuclear deexcitation. As an example of the former method the relationship between the decay rate of /sup 99m/Tc and the chemical structures of pertechnetate and bis(meso-dimercapto-succinate)oxotechnetate(V) is considered. Lower expectations with respect to measuring techniques are associated with the observation of X-ray emission. For a number of elements (especially 3d transition elements) the K/sub ..cap alpha..//K/sub ..beta../ X-ray ...
Radionuclides exhibiting in decaying a strong interaction between nucleus and electron shell (especially electron capture and internal conversion) are, in principle, sensitive to their chemical surroundings. Consequently, they can be used to yield chemical information after an appropriate labelling procedure. The information can be extracted from the decay rate variation as well as from their X-ray emission as a response to an inner-shell vacancy creation during nuclear deexcitation. As an example of the former method the relationship between the decay rate of /sup 99m/Tc and the chemical structures of pertechnetate and bis(meso-dimercapto-succinate)oxotechnetate(V) is considered. Lower expectations with respect to measuring techniques are associated with the observation of X-ray emission. For a number of elements (especially 3d transition elements) the K/sub #alpha#//K/sub #betta#/ X-ray intensity ...
The devised radionuclide analyzer for the determination of total sulfur in coal includes two radionuclide sources with different energies, which are accommodated in collimators fitted with adjustable diaphramgs. The sample compartment is located between the two sources. Moreover, an X-ray fluorescence standard can be slid into the sample compartment. A proportional detector for X-ray fluorescence and scattered gamma radiation is located off the sample compartment. The input of the proportional detector is interfaced to the output of a high-voltage supply, the output, to the information input of a control-and-evaluation unit. One of the control outputs of the control-and-evaluation unit is connected to the input of the sliding mechanism for the X-ray fluorescence standard. This arrangement enables automatic energy calibration of the analyzer. The analyzer can measure not only total sulfur in coal by radionuclide ...
Fe{sub x}Zn{sub 1-x} alloys were electrochemically deposited on aluminum substrates from a sulfate bath. The K{beta}/K{alpha} x-ray intensity ratios of Zn and Fe in Fe{sub x}Zn{sub 1-x} thin films have been experimentally studied. The energy dispersive x-ray fluorescence (EDXRF) technique was used to measure K x-ray photons. Samples were excited by using 59.5 keV photons emitted by a 50 mCi {sup 241}Am radioactive source. The emitted K x-rays were detected by an Ultra-LEGe detector having a resolution of 150 eV at 5.9 keV. In addition, the effect of bath composition on the phase structure was investigated by x-ray diffraction (XRD) analysis. The composition of the thin films was analyzed by atomic absorption spectrometry analysis. Iron content was shown to strongly affect the structure of Zn-Fe alloys. It was found that the K-shell x-ray ...
FexZn1-x alloys were electrochemically deposited on aluminum substrates from a sulfate bath. The K?/K? x-ray intensity ratios of Zn and Fe in FexZn1-x thin films have been experimentally studied. The energy dispersive x-ray fluorescence (EDXRF) technique was used to measure K x-ray photons. Samples were excited by using 59.5 keV photons emitted by a 50 mCi 241Am radioactive source. The emitted K x-rays were detected by an Ultra-LEGe detector having a resolution of 150 eV at 5.9 keV. In addition, the effect of bath composition on the phase structure was investigated by x-ray diffraction (XRD) analysis. The composition of the thin films was analyzed by atomic absorption spectrometry analysis. Iron content was shown to strongly affect the structure of Zn-Fe alloys. It was found that the K-shell x-ray intensity ratio changed in FexZn1-x thin ...
A comparative study by Eu-L_I_I_I X-rayabsorption and "1"5"1Eu-Moessbauer spectroscopy is presented for the EuPd_2_-_xAu_x Si_2 series. Possible ways to distinguish between mixed-valent behaviour and final-state effects in the L_I_I_I-edge spectra are discussed.
A comparative study by Eu-L/sub III/ X-rayabsorption and /sup 151/Eu-Moessbauer spectroscopy is presented for the EuPd/sub 2-x/Au/sub x/ Si/sub 2/ series. Possible ways to distinguish between mixed-valent behaviour and final-state effects in the L/sub II /I-edge spectra are discussed.
Arsenic in soils from the Asarco Lead Smelter in East Helena, Montana was characterized by X-rayabsorption spectroscopy (XAS). As oxidation state and geochemical speciation were analyzed as a function of depth (two sampling sites) and surface distribution. These results were c...
Collisional-Radiative numerical models are commonly used to design or interpret experiments in atomic physics of laser-created plasmas, including X-ray laser studies. We describe our new code containing several options: average ion, more or less detailed configurations. It consists of an atomic data base coupled to subroutines evaluating ionic populations and emission and absorption coefficients. Numerical results are given to illustrate the capabilities of the code and to compare different models and types of approximation.
Cerium [ital L][sub 3] XANES (x-ray-absorption near-edge-structure) spectra were analyzed to separate Ce moment contributions and mixed valence (MV) in complex magnetic silicides CePd[sub 2[minus][ital x
The results of X-ray and neutron diffraction experiments on molten alkali halides in which some data of our experiments by X-ray diffraction such as those of molten LiCl, NaCl, KCl, LiBr and KBr are included were summarized. The first peak positions in the radial distribution function in molten alkali halides by X-ray or neutron diffraction experiments are always longer than those by computer simulations and the differences of 0.1 -- 0.3 A exceed the experimental error. It seems to be due to the deformation of the electron shell. In the computer simulation, the shell model which has the spherical deformation was expected to have a closer value of the first peak position to the experimental one than the rigid ion model by taking the polarization of ions. However, no change in the first peak position was found. Therefore, the non-spherical deformation of electron shell at the point where ions are in contact with each other ...
The results of X-ray and neutron diffraction experiments on molten alkali halides in which some data of our experiments by X-ray diffraction such as those of molten LiCl, NaCl, KCl, LiBr and KBr are included were summarized. The first peak positions in the radial distribution function in molten alkali halides by X-ray or neutron diffraction experiments are always longer than those by computer simulations and the differences of 0.1 -- 0.3 A exceed the experimental error. It seems to be due to the deformation of the electron shell. In the computer simulation, the shell model which has the spherical deformation was expected to have more closer value of the first peak position to the experimental one than the rigid ion model by taking the polarization of ions. However, no change in the first peak position was found. Therefore, the non-spherical deformation of electron shell at the point where ions are in contact with each other ...
Scatter correction is crucial to the quality of reconstructed images in x-ray cone-beam computed tomography (CBCT). Most of existing scatter correction methods assume smooth scatter distributions. The...Full Text Available
Small-angle X-ray scattering method recognised to be very useful in the studies of structural problems of materials in homogeneous in nanoscale. Studies by small-angle X-ray scattering on the Al-Ag alloys are presented. The size distributions of spherical Guinier-Person zones were calculated using Vonk's and Glatter's methods. Small-angle X-ray scattering studies were performed on Al-5.0 at.%Ag alloy containing Guinier-Preson zones in the #eta#-state. For this alloy one can assume that scattering particles are of spherical shape, have uniform electron density and scatter independently. Moreover, the size distributions were calculated for Al-1.6 at.%Ag alloy containing Guinier-Preston zones in #epsilon#-state (scattering particles with not uniform electron density). Both, Vonk's and Glatter's, methods gave similar size distributions. Profiles of size ...
We performed experimental studies on the convolution/superposition method reported in the former companion paper (Iwasaki in Radiol Phys Technol 4, 2011) using 10-MV X-ray beams from open-jaw-collimated fields. The method uses primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. We made a comparison of calculations and measurements in water phantoms and thorax-like phantoms with respect to percentage depth dose curves, tissue???phantom ratio curves, and dose profiles. We made the dose calculation by taking into account the beam-hardening effect with depth and the off-axis radiation-softening effect. We found that the method could be used, in general, for performing accurate dose calculations.
The present study attempts to use hydrogen peroxide solution to humidify Ca(OH)(2) particles to enhance the absorption of SO(2) to achieve higher removal efficiency and to solve the valuable reuse of the reaction product in the semidry flue gas desulfurization (FGD) process. Experiments were carried out to examine the effect of various operating parameters including hydrogen peroxide solution concentration, Ca/S molar ratio and approach to adiabatic saturation temperature on SO(2) removal efficiency in a laboratory scale spray reactor. The product samples were analyzed to obtain semi-quantitative measures of mineralogical composition by X-ray diffraction (XRD) with reference intensity ratio (RIR) method and the morphology of the samples was examined by scanning electron microscope (SEM). Compared with spraying water to humidify Ca(OH)(2), SO(2) removal efficiency was improved significantly by spraying hydrogen peroxide ...
A high degree of structural perfection is an essential requirement for CdTe crystals used as substrates for the epitaxial growth of CdHgTe alloys. Here, a method for the evaluation of the structural perfection of CdTe crystals is proposed which is based on X-ray diffraction measurements using both two-crystal and three-crystal diffractometers (differential version). The method makes it possible to obtain more information on structural perfection both at the crystal surface and within the crystal body.
Double-crystal high-resolution x-ray fluorescence spectrometry was applied to the state analysis of sulfur in coal and related fly ash. For total sulfur, a proportional relationship exists between fluorescence intensities and the analytical values obtained by the oxygen-combustion method. Two oxidation states of sulfur were identified by a least square curve fitting method, by assuming that the spectrum profile is identical for each sulfur state but the intensity and position are different. The chemical state of sulfur in coal and remaining in fly ash is discussed.
A study of the thin gold film growth, during the deposition on glass substrate under UHV conditions at low temperatures, is presented. The complementary methods, the atomic force microscopy and grazing incidence x-ray reflectometry, are used for the research. It is shown that due to variation of the time of deposition from 2 to 50 min different kinds of thin Au films nanostructures are obtained: from discontinuous films consisting of isolated islands, via formation of the chains of islands, up to continuous films. (author)
A theoretical analysis is presented for the method of determining the concentration distribution of admixtures in zone melting and in the study of diffusion in melts. Continuous mode X-ray fluorescence analysis is considered. The convolution integral interpreting the analog output of the ratemeter was solved applying the mathematical apparatus of Z transformation. The feasibility of the method is tested on an example of the determination of tin distribution in tungsten. With respect to the statistical error (#delta#<1.5%), the maximum integration constant (100 s) and a very slow sample feed (0.025 mm/s) were used. The calculated transfer function reflects the total transfer function of the ratemeter and the recorder used. (M.D.).
The conductive ultra thin films were fabricated from mixed monolayers containing stearic acid and Head-to-Tail poly(3-alkylthiophene). These films exhibited well-defined layered structures as determined by optical absorption and X-ray diffraction measurements. The UV-Vis absorption spectra of these films showed lower energy absorption shifts of 48 nm from that of the random poly(3-alkylthiophene)/stearic acid LB films. The blue shift of absorption maximum of the LB film is attributed to the increase of {pi}-conjugation length caused by no steric hindrance of alkyl side chains. The conductivity of the Head-to-Tail poly(3-hexylthiophene)/stearic acid LB films was greatly improved in the range of 67-100 S/cm. (orig.)
The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)
Most surface-acoustic-wave and thin-film optical devices are made by the planar fabrication process. The exposure of the pattern in the polymer film is the first and most crucial step in ensuring desired device geometry, dimensional control, and freedom from pattern distortion. The methods of exposing the polymer film include: optical projection, conventional contact printing, conformable photomask contact printing, holographic recording, scanning electron beam lithography, projection electron lithography, and x-ray lithography. In this paper scanning electron beam lithography, conformable photomask contact printing, holographic recording, and x-ray lithography are discussed. In the last section, ion beam etching of relief structures is discussed.
Purpose: Reconstruction of organ doses of selected organs and tissues from radiographic settings and exposure data collected during chest X-ray examinations of children of various age groups performed in Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007. Materials and Method: The dosimetric data of all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 119 150 chest radiographs of all age groups. Reconstruction of organ doses in 40 organs and tissues in X-ray examinations of the chest was performed based on the conversion factor concept. Results: The radiation exposure of organs in projection radiography is determined by the exact site of the organs ...
This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is ...
The effect that different chemical and physical atomic environments can have on the relative intensities of radiative electron transitions from the filling of K shell vacancies was investigated. The method used involved the detection of photoionization induced X-ray fluorescence. An experimental system based on a hyper pure germanium detector (HPGE) was used to measure the relative K-L and K-M X-ray yields from the photofluorescence of a series of lanthanide elements and compounds. A background subtraction and peak integration strategy was employed which accounted for scattering in the samples and scattering of the flux from the radioisotope photoionization sources. Analysis of the data resulted in a tabulation of relative K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ratios. The measured relative K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ratios were compared to ...
The effect that different chemical and physical atomic environments can have on the relative intensities of radiative electron transitions from the filling of K shell vacancies was investigated. The method used involved the detection of photoionization induced X-ray fluorescence. An experimental system based on a hyper pure germanium detector (HPGE) was used to measure the relative K-L and K-M X-ray yields from the photofluorescence of a series of lanthanide elements and compounds. A background subtraction and peak integration strategy was employed which accounted for scattering in the samples and scattering of the flux from the radioisotope photoionization sources. Analysis of the data resulted in a tabulation of relative K/sub #beta#//K/sub #alpha#/ X-ray intensity ratios. The measured relative K/sub #beta#//K/sub #alpha#/ X-ray intensity ratios were compared to the calculated ...
Using Pd and Ag L3,2-edge x-ray-absorption near edge structures (XANES) and x-ray photoemission spectroscopy, we have investigated the charge distribution in a series of Pd-Ag alloys (Pd3Ag, PdAg, and PdAg3) from a local perspective. It is found that, relative to the pure element, both Pd and Ag gain d and lose non-d (s and p) charge upon alloying. The results are discussed in terms of band filling, rehybridization, electronegativity, and electroneutrality considerations. The possibility of using the L3,2-edge XANES white line to circumvent the need of an appropriate volume for charge transfer discussions and for other applications are noted.
The consistency of different instruments and methods for measuring two-dimensional (2D) power spectral density (PSD) distributions are investigated. The instruments are an interferometric microscope, an atomic force microscope (AFM) and the X-ray Reflectivity and Scattering experimental facility, all available at Lawrence Berkeley National Laboratory. The measurements were performed with a gold-coated mirror with a highly polished stainless steel substrate. It was shown that these three techniques provide essentially consistent results. For the stainless steel mirror, an envelope over all measured PSD distributions can be described with an inverse power-law PSD function. It is also shown that the measurements can be corrected for the specific spatial frequency dependent systematic errors of the instruments. The AFM and the X-ray scattering measurements were used to determine the modulation transfer function of the ...
The consistency of different instruments and methods for measuring two-dimensional (2D) power spectral density (PSD) distributions are investigated. The instruments are an interferometric microscope, an atomic force microscope (AFM) and the X-ray Reflectivity and Scattering experimental facility, all available at Lawrence Berkeley National Laboratory. The measurements were performed with a gold-coated mirror with a highly polished stainless steel substrate. It was shown that these three techniques provide essentially consistent results. For the stainless steel mirror, an envelope over all measured PSD distributions can be described with an inverse power-law PSD function. It is also shown that the measurements can be corrected for the specific spatial frequency dependent systematic errors of the instruments. The AFM and the X-ray scattering measurements were used to determine the modulation transfer function of the ...
The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.
The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).
The present work gives preliminary results of analysis of drug mixtures (NEPHROSAL tea bag) and its water infusion. In a sample of dried drugs the elements K, Ca, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, Pb were identified, whereas in their water infusion only Ca, Mn, Zn and Sr were found. The method applied was radionuclide X-ray fluorescence analysis using a radionuclide source "1"0"9Cd, a Si/Li semiconductor detector and a multichannel analyzer Canberra 8100. (author) 6 refs.; 3 figs.
The paper presents an integrated approach to the problem of electron temperature diagnostics of the plasma in a reversed field pinch. Three different methods, sampling different portions of the electron distribution function, are adopted, namely Thomson scattering, soft X-ray spectroscopy by pulse-height analysis and filtered soft X-ray intensity ratio. A careful analysis of the different sources of systematic errors is performed and a novel statistical approach is adopted to mutually validate the three independent measurements. A satisfactory agreement is obtained over a large range of experimental conditions, indicating that in the plasma core the energy distribution function is well represented by a maxwellian. (author)
Radionuclide X-ray fluorescence method with a Si/Li semiconductor detector and "2"3"8Pu exciting source was used in the study of Mn, Fe, Cu, Zn, and Pb content of solid emissions, raw and final materials of a brick factory. From the point of view of metal content, the working environment if the brick factory is safe for workers. (author) 2 refs.; 2 figs.; 1 tab.
Bremstrahlung Isochromat Spectroscopy (BIS). The XES spectra were collected using a Specs electron gun for the excitation and the XES 350 grating monochromator and channel plate system from Scienta as the photon detection. Spectra were collected in 'normal mode,' where the electron gun kinetic energy (KE) and the energy position of the center of the channel plate were both fixed and the energy distribution in the photon (hv) spectrum was derived from the intensities distributed across the channel plate detector in the energy dispersal direction. The polycrystalline Ce sample was oxidized by exposure to air at ambient pressures. After introduction to the ultra-high vacuum system, the oxidized sample was bombarded with Ar, to clean the topmost surface region and stabilize the surface and near surface regions. Although CeO{sub 2} would be the thermodynamically preferred composition in an oxygen rich environment, the combination of a vacuum environment and ion etching may ...
We report the experimental and theoretical results on the anisotropies in the magnetic properties and x-rayabsorption spectra of single-crystal LiFePO4. A mean-field theory is developed to explain the observed strong anisotropies in Lande g-factor, paramagnetic Curie temperature, and effective moment for LiFePO4 single crystals. The values of the in-plane nearest- and next-nearest-neighbor spin exchange (J1 and J2), interplane spin exchange (J{perpendicular}), and single-ion anisotropy (D), obtained recently from neutron scattering measurements, are used for calculating the Curie temperatures with the formulas derived from the mean-field Hamiltonian. It is found that the calculated Curie temperatures match well with that obtained by fitting the magnetic susceptibility curves to the modified Curie-Weiss law. For the polarized Fe K-edge x-rayabsorption spectra of single-crystal LiFePO4, a different ...
The structural parameters of various Haegg phases (H or M_n_+_1AX_n phases) are studied experimentally by x-ray and electron spectroscopies, x-ray diffraction, and ab initio full potential as well as full mutiple scattering theoretical calculations. Experimentally it was found that the structure of all ternary compounds analyzed herein are relaxed. The values of the lattice parameters and relaxations obtained from ab initio calculations are in excellent agreement with those deduced from the analysis of the experimental data. The bonding scheme has been analyzed and the charge transfer between constituting atoms determined. It is demonstrated that the strength and electrical transport properties in these materials are principally governed by the metallic planes. For the solid solution (Ti_0_._5Nb_0_._5)_2AlC, the most salient result is that the basal planes are corrugated, which could explain the solid solution scattering observed in this H ...
The NiO-samaria doped ceria (SDC) composite powders were prepared by spray pyrolysis technique at temperatures between 400 and 1000 C. The variation of the particle structure was investigated by X-ray diffraction (XRD), X-rayabsorption fine structure (XAFS), scanning electron microscope (SEM), and transmission electron microscope (TEM)-energy-dispersive X-ray spectroscopy (EDS). The thermal analysis of raw materials was also carried out. The following facts became clear in this study. Ceria and nickel have been already separated at 400 C. Samaria is amorphous phase below 600 C, and is dissolved in ceria at 600 C or higher. Samaria is distributed uniformly inside the particles before dissolving in ceria. The thermal decomposition temperatures of metal nitrate are: cerium < nickel < samarium. The results of these analyses were explained without contradiction. It was found that it is ...
Chandra and XMM surveys show that the fraction of obscured AGN decreases rapidly with increasing luminosity. Although this is usually explained by assuming that the covering factor of the central engine is much smaller at luminous QSOs, the exact origin of this effect remains unknown. We perform toy simulations to test whether photo-ionisation of the obscuring screen in the presence of a strong radiation field can reproduce this effect. In particular, we create X-ray spectral simulations using a warm absorber model assuming a range of input column densities and ionization parameters. We fit instead the simulated spectra with a simple cold absorption power-law model that is the standard practice in X-ray surveys. We find that the fraction of absorbed AGN should fall with luminosity as $L^{-0.16\\pm0.03}$ in rough agreement with the observations. Furthermore, this apparent decrease in the obscuring material is consistent with ...
This work reports studies of ethanol oxidation on Pt-Sn/C catalysts with nearly the same particle size and identical overall composition having different amounts of oxide and alloyed phases. Results of characterization of physical properties by transmission electron microscopy (TEM), X-ray diffraction (XRD), differential scanning calorimetry (DSC), X-ray photoelectron spectroscopy (XPS), and in situ dispersive X-rayabsorption spectroscopy (DXAS) are presented. The variation in the amount of oxide and alloyed phases, promoted by heat treatments in mild temperature conditions, does not produce any significant particle growth. Cyclic voltammetry and oxidation of adsorbed CO in acid medium are used to probe the surface conditions. Data on the electrocatalytic activity towards ethanol oxidation, obtained by potential sweeps and chronoamperometry, are discussed and correlate well with the physical ...
The K{beta}-to-K{alpha} X-ray intensity ratio of Ni in Ni{sub 3}Si, Ni{sub 2}Si and NiSi has been determined by energy dispersive X-ray fluorescence technique. It is found that the intensity ratio of Ni decreases from pure Ni to Ni{sub 2}Si and then increases from Ni{sub 2}Si to NiSi, in good agreement with the electronic structure calculations cited in the literature. We have also performed band structure calculations for pure Ni in various atomic configurations by means of linear muffin-tin orbital method and used this data with the normalized theoretical intensity ratios cited in the literature to estimate the 3d-occupation numbers of Ni in Ni-Si alloys. It is emphasized that investigation of alloying effect in terms of X-ray intensity ratios should be carried out for the stoichiometric alloys in order to make reliable and quantitative comparisons between theory and experiment in transition metal ...
When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated through contrast ...
When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated through contrast ...
This work analyzes the unoptimized prototype triode-sputtered, 150 microns thick tantalum coatings deposited with a 2.5 microns niobium underlayer on the bore of a large-diameter A723 steel cylinder. The coating was deposited for wear and erosion protection by Pacific Northwest National Laboratory. The phase determination was based on Xray diffraction analysis, wavelength dispersive Xray fluorescence analysis, energy dispersive Xray analysis, and hardness and electrical resistivity measurements. Both Xray diffraction and radius-of- curvature methods were used to determine residual stresses. A locally developed high-resolution pole figure technique was used to perform texture analysis. The post-firing, debonded coating showed alpha-tantalum, preferred 110 orientation, high surface stresses, ...
X-ray fluorescence (XRF) and total-reflection X-ray fluorescence (TXRF) techniques suited well for a multi-element determination of K, Ca, Mn, Fe, Cu, Zn, Rb, and Sr in some Syrian medicinal plant species. The accuracy and the precision of both techniques were verified by analyzing the Standard Reference Materials (SRM) peach-1547 and apple leaves-1515. A good agreement between the measured concentrations of the previously mentioned elements and the certified values were obtained with errors less than 10.7% for TXRF and 15.8% for XRF. The determination of Br was acceptable only by XRF with an error less than 24%. Furthermore, the XRF method showed a very good applicability for the determination of K, Ca, Mn, Fe, Cu, Zn, Rb, Sr, and Br in infusions of different Syrian medicinal plant species, namely anise (Anisum vulgare), licorice root (Glycyrrhiza glabra), and white wormwood (Artemisia herba-alba)
A WO(3)/TiO(2) composite, hollow-sphere photocatalyst with average diameter of 320 nm and shell thickness of 50 nm was successfully prepared using a template method. UV-vis diffuse reflectance spectra illustrated that the main absorption edges of the WO(3)/TiO(2) hollow spheres were red-shifted compared to the TiO(2) hollow spheres, indicating an extension of light absorption into the visible region of the composite photocatalyst. The WO(3) and TiO(2) phases were confirmed by X-ray diffraction analysis. BET isotherms revealed that the specific surface area and average pore diameter of the hollow spheres were 40.95 m(2)/g and 19 nm, respectively. Photocatalytic experiments indicate that 78% MB was degraded by WO(3)/TiO(2) hollow spheres under visible light within 80 min. Under the same conditions, only 24% MB can be photodegraded by TiO(2). The photocatalytic mineralization of MB, catalyzed by TiO(2) and ...
We examined a catalytic effect of niobium oxide (Nb{sub 2}O{sub 5}) on the hydrogen storage properties of MgH{sub 2} prepared by mechanical ball milling method. The MgH{sub 2} composite doped with 1 mol% Nb{sub 2}O{sub 5} by ball milling for 20 h desorbed hydrogen up to {approx}6 mass% in the temperature range from 200 to 250 {sup o}C at the heating rate of 5 {sup o}C/min under a purified helium flow. After dehydrogenation at 200 {sup o}C, the product showed remarkable hydrogen absorption kinetics. A large amount of gaseous hydrogen up to {approx}4.5 mass% was absorbed even at room temperature under 1 MPa hydrogen pressure within 15 s and finally its capacity reached up to 5 mass%. Furthermore, the valence state of Nb{sub 2}O{sub 5} doped in MgH{sub 2} was examined by X-rayabsorption near edge structure (XANES) measurement. The results indicated that additive Nb{sub 2}O{sub 5} was reduced by MgH{sub 2} ...
... The constancy of the X-ray intensity ratio for each element in Table 8 as the X-ray tube settings were changed shows the excellent compensating ...
The purpose of the present study is to develop a new method for chemical state analysis by means of EPMA(Electron probe microanalyser). The measured X-ray intensity of Si-K{beta} characteristic X-ray spectra were read-out by a 16 bit microcomputer with a RS-232C interface. And using the curve fitting method the quantitative analysis of chemical compositions in a ternary compound that constituted of the same element has been established. The present method was applied to analyse of the friction and wear properties of Si-base ceramics sliding materials. It was found that the wear debris contains both the compositions of the sliding materials and SiO{sub 2}, and the SiO{sub 2} contents in wear debris was changed with relative humidity. The results clearly showed that the proposed method is very useful for determing the compositions in the ternary compound. ...
The purpose of the present study is to develop a new method for chemical state analysis by means of EPMA(Electron probe microanalyser). The measured X-ray intensity of Si-K#beta# characteristic X-ray spectra were read-out by a 16 bit microcomputer with a RS-232C interface. And using the curve fitting method the quantitative analysis of chemical compositions in a ternary compound that constituted of the same element has been established. The present method was applied to analyse of the friction and wear properties of Si-base ceramics sliding materials. It was found that the wear debris contains both the compositions of the sliding materials and SiO_2, and the SiO_2 contents in wear debris was changed with relative humidity. The results clearly showed that the proposed method is very useful for determing the compositions in the ternary compound. (author).
It has been discovered that the presence of MoO/sub 3/ lowers the ..cap alpha..-..beta.. transition in Sb/sub 2/O/sub 4/ from 935 to 850/sup 0/C with concurrent dissolution of Mo in the high-temperature (..beta..) form. The structure of Mo-doped ..beta..-Sb/sub 2/O/sub 4/ has been investigated by powder neutron diffraction, extended X-rayabsorption fine structure (EXAFS) and Raman spectroscopies, and scanning-electron microscopy (SEM). Cell parameters: a = 12.0571 (12) A, b = 4.8335 (1) A, c = 5.3838 (6) A, ..beta.. = 105.579 (5)/sup 0/, monoclinic, space group C2/c, Z = 4. Combining the results of these techniques leads to the hypothesis that Mo is located interstitially within channels of electron density in the Sb/sub 2/O/sub 4/ structure with concurrent vacancy of two Sb/sup III/ atoms. There is no apparent oxygen deficiency in the resulting structure. 25 references, 6 figures, 3 tables.
Research highlights: {yields} The polarization curve of 316L SS possesses five turning potentials in passive region. {yields} Films formed at turning potentials perform different electrochemical and semiconductor properties. {yields} Dissolutions and regenerations of passive film at turning potentials are obtained by AAS and XPS. {yields} Turning potentials appearing in passive region are ascribed to the changes of the compositions of the passive films. - Abstract: The passivity of 316L stainless steel in borate buffer solution has been investigated by Mott-Schottky, atomic absorption spectrometry (AAS) and X-ray photoelectron spectroscopy (XPS). The results indicate that the polarization curve in the passive region possesses several turning potentials (0 V{sub SCE}, 0.2 V{sub SCE}, 0.4 V{sub SCE}, 0.6 V{sub SCE} and 0.85 V{sub SCE}). The passive films formed at turning potentials perform different electrochemical and semiconductor properties. ...
Understanding the mechanical properties of biomedical devices is critical in predicting and preventing their failure in the body. Such knowledge is essential, for example, in the design of biomedical stents, which must undergo repeated strain over their ten year lifetimes without breaking. Computational models are used to predict mechanical response of a device, but these models are not complete; there are significant deviations from the predictions, especially when devices are subjected to repeated multi-axial loads. Improving these models requires comparisons with actual measurements of strained nitinol. Local measurements of the full strain tensor can be made using X-ray diffraction techniques, but they are currently limited to materials whose grain size is larger than the X-ray beam size or require several diffraction patterns produced by rotation of the sample. Nitinol stents are nanocrystalline, with grains smaller than any available ...
Full text of publication follows: Large-scale problems such as nuclear waste disposal are increasingly recognized to be interconnected to small scale-mechanisms. Thus, synchrotron-based high-resolution analytical X-ray probes become important tools for exploring the micro-scale chemical reactivity of heterogeneous barrier materials used in nuclear waste repositories. In this study the layout of the micro-XAS beamline at the Swiss Light Source (SLS) will be presented. The beamline is optimized towards micro beam experiments ({approx}1 x 1 {mu}m{sup 2}) in the hard-X-ray regime (4 - {approx}22 keV) and allows to combine micro X-ray fluorescence (micro-XRF), micro X-rayabsorption spectroscopy (micro- XAS), and micro X-ray diffraction (micro-XRD) investigations with radioactive samples. Furthermore, the potential of micro-XRF/XAS/XRD for acquiring spatially ...
The possibility of gamma-absorption identification of the analyzed substance is considered. the basic provisions of the proposed method are concentrated on the example of carbohydrates and hydrocarbons. The above method is tested experimentally on polyethylenes and polystyrene
The principle of conservation and transferability of chemical bonds explains the recent discovery by extended x-rayabsorption fine-structure measurements of two unequal anion-cation bond lengths R/sub A/C and R/sub B/C in A/sub x/B/sub 1-x/C zinc-blende semiconductor alloys despite the close adherence of the lattice constant to the average value (Vegard rule). This bond alternation, manifested as a structural distortion to a local chalcopyrite coordination around the anions, explains also most of the observed optical bowing in semiconductor alloys.
The principle of conservation and transferability of chemical bonds explains the recent discovery by extended x-rayabsorption fine-structure measurements of two unequal anion-cation bond lengths R/sub A/C and R/sub B/C in A/sub x/B/sub 1-x/C zinc-blende semiconductor alloys despite the close adherence of the lattice constant to the average value (Vegard rule). This bond alternation, manifested as a structural distortion to a local chalcopyrite coordination around the anions, explains also most of the observed optical bowing in semiconductor alloys.
The study is concerned with the combined effect of high pressure and shear strain on the properties of the A-15 intermetallics Nb3Sn and Nb3Al0.75Ge0.25. The properties discussed are the superconducting transition temperature, the width and intensity of the X-ray diffraction lines, and the width and shape of the Mossbauer absorption lines. It is shown that the combined effect of high pressure and shear strain leads to an intense generation of defects in polycrystalline specimens; the size of the ordered regions does not exceed 300 A even under the least severe conditions. 5 references.
Total photon attenuation coefficients near absorption edges are determined in certain suitable elements and compounds. Photoelectric cross sections for elements are deduced from these by subtracting the coherent and incoherent scattering cross sections as well as other elemental cross sections in the cases of compounds. Certain deviations are observed on comparison with the available theoretical and experimental compilations. The I/sub L//sub ..cap alpha..//Il x-ray intensity ratio measured by photon excitation near threshold is found to agree better with the theory than the other available experimental data.
Total photon attenuation coefficients near absorption edges are determined in certain suitable elements and compounds. Photoelectric cross sections for elements are deduced from these by subtracting the coherent and incoherent scattering cross sections as well as other elemental cross sections in the cases of compounds. Certain deviations are observed on comparison with the available theoretical and experimental compilations. The I/sub L//sub #alpha#//Il x-ray intensity ratio measured by photon excitation near threshold is found to agree better with the theory than the other available experimental data.
The magnetic and electronic properties of non-Fermi liquid UCu{sub 4Pd} depend on annealing conditions. Local structural changes due to this annealing are reported from UL{sub III}- and Pd K-edge x-rayabsorption fine-structure measurements. In particular, annealing decreases the fraction of Pd atoms on nominally Cu 16e sites and the U-Cu pair-distance distribution width. This study provides quantitative information on the amount of disorder in UCu{sub 4Pd} and allows an assessment of its possible importance to the observed non-Fermi liquid behavior.
The task of designing high performance X-ray optical systemsrequires the development of sophisticated X-ray scattering calculationsbased on rigorous information about the optics. One of the mostinsightful approaches to these calculations is based on the powerspectral density (PSD) distribution of the surface height. The majorproblem of measurement of a PSD distribution with an interferometricand/or atomic force microscope arises due to the unknown ModulationTransfer Function (MTF) of the instruments. The MTF characterizes theperturbation of the PSD distribution at higher spatial frequencies. Here,we describe a new method and dedicated test surfaces for calibration ofthe MTF of a microscope. The method is based on use of a speciallydesigned Binary Pseudo-random (BPR) grating. Comparison of atheoretically calculated PSD spectrum of a BPR grating with a spectrummeasured with the grating provides the ...
The purpose of this research is to investigate the micro-mechanism of deformation behavior of metallic glasses. We report the results of direct observations of short-range and medium-range structural change during tensile deformation of metallic glasses by high energy X-ray diffraction method. Cu50Zr50 and Ni30Zr70 metallic glass samples in the ribbon shape (1.5 mm width and 25 ?m) were made by using rapid quenching method. Tensile deformation added to the sample was made by using special equipment adopted for measuring the high energy X-ray diffraction. The peaks in pair distribution function g(r) for Cu50Zr50 and N30iZr70 metallic glasses move zigzag into front and into rear during tensile deformation. These results of direct observation on atomic distribution change for Cu50Zr50 and Ni30Zr70 metallic glass ribbons during tensile deformation suggest that the micro-relaxations occur.
A method for using in situ X-rayabsorption near edge spectroscopy to determine the composition of passive, transpassive, and nonreducible thin oxide films is described. The method is demonstrated by determining the composition of the passive films formed in pH 4.5, 0.1 M acetate buffer, on 100 {angstrom} thick Fe-yCr alloys (y = 8.5, 15, 19, 23 atom %) at potentials: (1) low in the passive region ({minus}0.3 V vs. mercurous sulfate reference electrode, MSE); (2) high in the passive region; (3) in the transpassive region; and (4) in the cathodic region where the air-formed film is not fully reduced. The nonreducible film at {minus}1.2 V is entirely a Cr{sup 3+} oxide/hydroxide. This nonreducible film persists at anodic potentials. At {minus}0.3 V, the passive film on each alloy is significantly enriched in Cr. The film at {minus}0.3 V consists primarily of the nonreducible Cr{sup 3+} oxide/hydroxide ...
Ultra low loading noble metal (0.04-0.12 mg_P_t/cm"2) based electrodes were obtained by direct metallization of non-catalyzed gas diffusion layers via dual ion beam assisted deposition (IBAD) method. Fuel cell performance results reported earlier indicate significant improvements in terms of mass specific power density of 0.297 g_P_t/kW with 250 A thick IBAD deposit (0.04 mg_P_t/cm"2 for a total MEA loading of 0.08 mg_P_t/cm"2) at 0.65 V in contrast to the state of the art power density of 1.18 g_P_t/kW using 1 mg_P_t_(_M_E_A_)/cm"2 at 0.65 V. In this article we report the peroxide radical initiated attack of the membrane electrode assembly utilizing IBAD electrodes in comparison to commercially available E-TEK (now BASF Fuel Cell GmbH) electrodes and find the pathway of membrane degradation as well. A novel segmented fuel cell is used for this purpose to relate membrane degradation to peroxide generation at the electrode/electrolyte interface by means of ...
Double-crystal high-resolution X-ray fluorescence spectrometry was applied to the state analysis of sulfur in coal and related fly ash. For total sulfur, a proportional relationship exists between fluorescence intensities and the analytical values obtained by the oxygen-combustion method. Two oxidation states of sulfur were identified by a least square curve fitting method, by assuming that the spectrum profile is identical for each sulfur state but the intensity and the position are different. Sulfur in coal mainly consists of S/sup 2 -/, whereas that in coal fly ash mainly consists of S/sup 6 +/. As much as 0.04-0.08% of S/sup 2 -/ remains in fly ash.
The use of X-ray diffraction line profile analysis for the study of nanocrystalline powders is described. The fundamentals of the theory are presented in terms of crystallite/domain size, size distribution, lattice distortion, dislocations density and stacking faults. Line profile parameters and the methods of pattern fitting introduced to overcome the diffraction-line overlap problem are discussed. The approaches based of the integral breadth of the measured line profiles and the Fourier method are discussed. In addition, simplified approaches are also commented. Representative examples are selected to illustrate various cases of microstructure, such as nanomaterials with strain-free spherical nano crystallites, strain-free crystallites with anisotropic crystallite shape, anisotropic crystallites with microstrains and spherical crystallites with dislocation densities and crystallite size distributions. (author)
Cluster calculations of the electronic structure and charge distribution in V_3Si have been performed using two different molecular orbital methods: a semiempirical LCAO and the MS X#alpha# model. The results are compared with X-ray emission spectra and band structure calculations. An analysis of the calculated electronic distribution reveals a charge transfer from Si-atoms to V-atoms, the additional charge on a V-atom being 0.6e (LCAO) and 0.4e (MS X#alpha# method). The results are in good agreement with experiment, which indicates that the cluster approach is adequate for the description of charge distributions and spectra characteristics of the A-15 compounds. (author).
This paper aimed to the evaluation of different kinds of sorbent material preparation and to the evaluation of their characteristics at different pH conditions by X-ray fluorescence analysis. This method is suitable for identification and determination of elements in samples of different character, state and origin because it is a polycomponent, non-destructive, fast and simple analytical method. Moreover, it allows timeadvantageous and reliable measurements. This paper studies problems concerning the determination of some selected elements (Mn, Fe, Ni, Cu, Zn, Pb) in pharmaceutical samples of sodium chloride in the solid state as well as in its solution by sorption on chelating extraction membrane 3M Empore"T"M and on the strongly acidic ion-exchanger Dowex 50Wx8. Conditions for the most effective sorption of determined elements are also interpreted. (author)
This paper aimed to the evaluation of different kinds of sorbent material preparation and to the evaluation of their characteristics at different pH conditions by X-ray fluorescence analysis. This method is suitable for identification and determination of elements in samples of different character, state and origin because it is a polycomponent, non-destructive, fast and simple analytical method. Moreover, it allows time-advantageous and reliable measurements. This paper studies problems concerning the determination of some selected elements (Mn, Fe, Ni, Cu, Zn, Pb) in pharmaceutical samples of sodium chloride in the solid state as well as in its solution by sorption on chelating extraction membrane 3M Empore? and on the strongly acidic ion-exchanger Dowex 50Wx8. Conditions for the most ef...
The compound semiconductor system InGaAsN exhibits many intriguing properties which are particularly useful for the development of innovative high efficiency thin film solar cells and long wavelength lasers. The bandgap in these semiconductors can be varied by controlling the content of N and In and the thin films can yet be lattice-matched to GaAs. In the present work, x-rayabsorption fine structure (XAFS) and grazing incidence x-ray scattering (GIXS) techniques have been employed to probe the local environment surrounding both N and In atoms as well as the interface morphology of InGaAsN thin films epitaxially grown on GaAs. The soft x-ray XAFS results around nitrogen K-edge reveal that N is in the sp{sup 3} hybridized bonding configuration in InGaAsN and GaAsN, suggesting that N impurities most likely substitute for As sites in these two compounds. The results of In K-edge XAFS suggest a possible ...
Reduction of silver myristate (AgMy) under mild thermal reaction conditions in a dipolar aprotic solvent i.e. N, N-dimethylformamide (DMF) has been carried out. UV-visible absorption measurements of dried and re-dispersible brown flocculants showed broad features of surface plasmon resonance (SPR) due to silver nanoparticles. The freshly isolated particles showed absorption bands at 414 and 485 nm, respectively, due to inter-particle coupling or clustering of silver ions and silver atoms. X-ray diffraction (XRD) pattern of fcc zero-valent silver resulted in crystallite size of about 10 nm. Scanning electron microscopy (SEM) revealed formation of rod shaped silver with increasing reaction temperature. Thermal analysis (TGA) showed about 10% weight loss due to organic capping.
Absorption spectra of the visible I_2 band of I_2 complexes with Et_2O, Et_2S, and Et_2Se in heptane have been measured up to 3300 bar at 25"0C. The equilibrium constants and volume changes accompanying complex formation, the molar extinction coefficients and the absorption maxima have been estimated. The volume changes were found comparable with those estimated from the X-ray data of the I_2 complexes in the crystalline state. The enhancement of the molar extinction coefficient and the blue shift of the visible I_2 band with increasing pressure have been established. The results suggest a decrease in the bond distance between an n-donor and I_2, compared with the spectroscopic properties of the I_2 complex at 1 bar. The decrease has been estimated as 0.008 nm with increasing pressure up to 3300 bar. (author).
The homogeneity of a helium dielectric barrier discharge, working at atmospheric pressure and containing oxygen as contaminant, is assessed by mapping the spatial distribution of oxygen metastable atoms in relation to the uniformity of surface properties. Tunable diode laser absorption spectroscopy is used to monitor the time evolution of the absorption coefficient corresponding to the oxygen metastable atoms on the 35S2 level, as a function of the laser absorbing path, whereas bi-dimensional Abel transform is used to obtain local information on the space distribution of the metastable atoms in the discharge. The radial distribution of the surface properties is investigated using atomic force microscopy, contact angle measurement and X-ray photoelectron spectroscopy. The results show that ...
An X-ray fluorometric train was set up for analyzing gravitational fallout, and tested on standard reference samples of fly ashes from conventional power plants. Analysis of thin layers proved inappropriate, and therefore pelletization of the samples, either alone or together with the X-ray MIX binder, was applied. Sample grinding in an agate mortar was found sufficient to suppress the particle size effect. The optimum pressure was 20 MPa. The optimum geometry was sought for "1"0"9Cd source, and limits of detection of 2.78-0.47 #mu#g were achieved for Cr-Zr elements. Tominaga's method was employed for matrix effect correction. Ti, Fe, Cu, Zn, As, Rb, Sr, Zr and Pb were determined in the SRM's; the relative errors ranged from units per cent (for Zn, Rb, Sr and Zr present in concentrations about 100 ppm and for Fe in concentrations of units per cent) up to 45% (for Ti present in a concentration of 0.67%). The ...
By dissolution of iron (2) carbonate in rhenium acid iron (2) perrhenate of the Fe(ReO/sub 4/)/sub 2/x4H/sub 2/O composition is obtained. By the method of thermal analysis the limits of tetra-, dihydrate and anhydrous iron (2) perrhenate stability are revealed. By means of Xray phase and IR spectroscopic analysis methods modification of structure in the process of synthesized salt dehydration is shown.
The etching method developed made it possible to observe under the microscope the finest components of the anatomical structure of coal-forming plants. The dependence of the effectiveness of etching of tissues on the concentrations of geopolymers (protocellulose and protolignin) in them was found. The study of tissues of this kind by the methods of local analysis (for example, X-ray microanalysis) allowed us to obtain the characteristics of the above geopolymers and to use them for the identification of the primary biochemical composition of fossil organic matter.
Technological processes of welding are significant sources of pollution in the working area. Evaluation of chemical quality of working area was made by means of radionuclide x-ray fluorescence analysis and activation analysis with fast neutrons. Welding aerosols were sampled by filtration method on Synpor 4 membrane ultra-filters. For selected types of welding filter metals, determination of heavy metals in aerosols was performed. (author).
Technological processes of welding are significant sources of pollution in the working area. Evaluation of chemical quality of working area was made by means of radionuclide x-ray fluorescence analysis and activation analysis with fast neutrons. Welding aerosols were sampled by filtration method on Synpor 4 membrane ultra-filters. For selected types of welding filter metals, determination of heavy metals in aerosols was performed.
Trace elements have been determined in biological samples including pepperwort, thyme, plantain, blessed thistle and common comfrey as well as cabbage leaves and milk powder. Concentrations of Al, Si, and Cl have been determined by fast neutron activation analysis while, in the case of Mg-, K, and Cl the X-ray fluorescence method was used.
Methods of sample treatment in XRF analysis of hair are studied in view of the effect on analytical results. A new method is proposed based on the incomplete ashing of hair followed by pellet preparation. Its suitability is estimated on the XRF analysis of real hair samples collected from 4 healthy adults. (author) 12 refs.; 4 figs.; 1 tab.
A method for calculation of absorbed dose distributions in three dimensions for 1-20 MeV photons is presented. The method uses convolution/superposition of photon fluence distributions with energy scattering kernels. Results for Co-60 and X-ray beams in homogeneous and inhomogeneous media are compared with measurements. Good agreement is found between calculations and measurements. 8 refs.; 3 figs.
A study on oxygen-plasma treatment of ink-jet paper is presented. Paper was exposed to a weakly ionized, highly dissociated oxygen plasma with an electron temperature of 5 eV, a positive-ion density of 8 x 1015 m-3 and a density of neutral oxygen atoms of 5 x 1021 m-3. Optical emission spectroscopy (OES) was applied as a method for detection of the reaction products during the plasma treatment of the paper. OES spectra between 250 and 1000 nm were measured continuously during the plasma treatment. The wettability of the samples before and after the plasma treatment was determined by measuring the contact angle of a water drop. The appearance of the surface-functional groups was determined by using high-resolution x-ray photoelectron spectroscopy (XPS), while changes in the surface morphology were monitored with scanning electron microscopy (SEM). Already after 1 s of the plasma treatment the surface, which was originally hydrophobic, changed to ...
The crystal structure of borophosphates ABPO{sub 5} (A = alkaline earth or Pb) was resolved on a polycrystalline sample using the Rietveld method. The x-ray diffraction patterns data show that ABPO{sub 5} crystallize in a centrosymmetric space group P3{sub 1}21 and their structure is related to the borogermanates REBGeO{sub 5} with a stillwellite-type structure. Pr{sup 3+} ion was used as a local structural probe to corroborate the structural resolution results. Absorption and fluorescence spectra of A{sub 1-x}Pr{sub x}BP{sub 1-x}Ge{sub x}O{sub 5} (A alkaline earth or Pb; x = 0.05) have been investigated at different temperatures. At 9 K the 3{sup H}{sub 4}{yields}{sup 3}P{sub 0} transition of trivalent praseodymium ion (4f{sup 2} configuration) is observed as a single line. This indicates a unique crystallographic site for the rare earth ion in these compounds replacing the divalent cation. Energy level schemes were ...
The crystal structure of borophosphates ABPO_5 (A = alkaline earth or Pb) was resolved on a polycrystalline sample using the Rietveld method. The x-ray diffraction patterns data show that ABPO_5 crystallize in a centrosymmetric space group P3_121 and their structure is related to the borogermanates REBGeO_5 with a stillwellite-type structure. Pr"3"+ ion was used as a local structural probe to corroborate the structural resolution results. Absorption and fluorescence spectra of A_1_-_xPr_xBP_1_-_xGe_xO_5 (A alkaline earth or Pb; x = 0.05) have been investigated at different temperatures. At 9 K the 3"H_4#->#"3P_0 transition of trivalent praseodymium ion (4f"2 configuration) is observed as a single line. This indicates a unique crystallographic site for the rare earth ion in these compounds replacing the divalent cation. Energy level schemes were deduced from the low-temperature spectroscopic measurements. Comparing the ...
Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance dose values of ...
Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance dose values of thoracoabdominal ...
Purpose: This study presents a dosimetric optimization effort aiming to compare intensity-modulated (IM) X-rays and IM protons in 4 different orbital and paraorbital tumors. These are most challenging targets for standard radiotherapy due to their close relationship with the eyes and related structures. Methods and Materials: A primary orbital lymphoma, an optic nerve meningioma, a sphenoidal ridge meningioma protruding into the orbit, and a pediatric parameningeal paraorbital rhabdomyosarcoma were selected for the purpose of this study. Planning target volumes (PTVs) and organs at risk (OAR) were defined in each patient CT data set for each tumor site. IM X-ray and IM proton three-dimensional treatment plans were implemented. The following total tumor doses were prescribed: 30 Gy for the orbital lymphoma, 54 Gy for both meningiomas, and 50.4 Gy for the rhabdomyosarcoma case. Dose-volume histograms (DVHs) were obtained for ...
Eu-#alpha#-SiAlON (Eu_m_/_2Si_1_2_-_m_-_nAl_m_+_nO_nN_1_6_-_n) was synthesized with nominal compositions having small m and n values, by firing the powder mixture of Eu_2Si_5N_8, #alpha#-Si_3N_4, AlN, and Al_2O_3 at 1900 "oC for 6 h under 1 MPa nitrogen atmosphere. The ratio of the oxidation state of Eu"2"+/Eu"3"+ was estimated from the X-rayabsorption fine structure (XAFS) measurement. The observed X-rayabsorption near edge spectrum (XANES) showed that the Eu ion in Eu-#alpha#-SiAlON was mainly in divalent state but also coexisted with a small amount of Eu in the trivalent state. The crystal structure of Eu-#alpha#-SiAlON was refined by the Rietveld analysis of the X-ray powder diffraction patterns. The lattice constants of the samples increased with increasing m and n values. The excitation band of Eu-#alpha#-SiAlON ranged from the ultraviolet to the visible light region and a ...
Radionuclide X-ray fluorescence analysis is a method, which has many advantages for analysing various historic artefacts, as it is relatively cheap, sensitive and non-destructive, and it allows measurements in-situ. However, this analysis has also certain limitations especially concerning sensitivity to chemical elements only, irrespective of the compounds or chemical forms in which these elements have been bonded. In addition, light elements emitting very soft X-rays cannot be measured, and in order to detect a wide range of elements, it is necessary to carry out repeated measurements with different radiation sources. Despite these limitations, valuable information can be obtained about the composition of historic materials and data about the origin and age of these artefacts can be derived. Analyses of wall paintings, ancient metal sculptures or other objects of art provide the basis for historic considerations documented ...
Radionuclide X-ray fluorescence analysis is a method, which has many advantages for analysing various historic artefacts, as it is relatively cheap, sensitive and non-destructive, and it allows measurements in-situ. However, this analysis has also certain limitations especially concerning sensitivity to chemical elements only, irrespective of the compounds or chemical forms in which these elements have been bonded. In addition, light elements emitting very soft X-rays cannot be measured, and in order to detect a wide range of elements, it is necessary to carry out repeated measurements with different radiation sources. Despite these limitations, valuable information can be obtained about the composition of historic materials and data about the origin and age of these artefacts can be derived. Analyses of wall paintings, ancient metal sculptures or other objects of art provide the basis for historic considerations documented ...
We have performed X-ray magnetic diffraction (XMD) experiment of ferromagnets at the Photon Factory (PF) of the High Energy Accelerator Research Organization (KEK) in Tsukuba. In this study, we have upgraded the XMD experimental system in order to apply this method to as many samples as possible. Upgrade was made for (1) the X-ray counting system and related measurement program, (2) the electromagnet, and (3) the refrigerator. The performance of the system was enhanced so that (1) the counting rate capability was improved from 104cps to 105cps, (2) the maximum magnetic field was increased from 0.85T to 2.15T, and (3) the lowest sample temperature was reduced from 15K to 5K. The new system was applied to an orbital ordering compound of YTiO3, and we obtained spin magnetic form factor for the reflection plane (010) perpendicular to the b axis. The magnetic field of 2T was needed to saturate the magnetization of YTiO3 along ...
(abridged) The accretion disk in AGN is expected to produce strong outflows, in particular a UV-line driven wind. Despite providing a good fit to the data, current spectral models of the X-ray spectrum of AGN observed through an accretion disk wind are ad-hoc in their treatment of the properties of the wind material. In order to address these limitations we adopt a numerical computation method that links a series of radiative transfer calculations, incorporating the effect of a global velocity field in a self-consistent manner (XSCORT). We present a series of example spectra from the XSCORT code that allow us to examine the shape of AGN X-ray spectra seen through a wind, for a range of velocity and density distributions, total column densities and initial ionization parameters. These detailed spectral models clearly show considerable complexity and structure that is strongly affected by all these factors. The presence of ...
The Schiff base ligand, 4-isopropylbenzaldehyde[N-(3-oxo-3,4-dihydro-2-quinoxalinyl)hydrazone] (Ipbh), the 1:1 condensation product of 4-isopropylbenzaldehyde and 2-hydroxy-3-hydrazinoquinoxiline, has been synthesized and characterized by X-ray crystallography. A series of complexes of Ipbh with Nickel(II), viz., [Ni(Ipbh)2]Cl2 (1), [Ni(Ipbh)2]Br2 (2), [Ni(Ipbh)2]I2 (3), [Ni(Ipbh)2(CH3OH)2](NO3)2(CH3OH)2 (4) and [Ni(Ipbh)2ClO4]ClO4 (5) have been synthesized. All the complexes were characterized by elemental analysis, molar conductivity, CHN analysis, spectroscopic studies, magnetic susceptibility measurements and TG/DTA methods. The solid-state structure of the complex 4 was established by single crystal X-ray crystallography. In all the complexes, Ipbh acts as a bidentate NO chelating age...
A technique for following sialon formation in situ by high temperature X-ray diffraction (HT-XRD) was developed. The composition chosen for study was an yttrium #alpha#-sialon with x=0.4. Powder compacts containing silicon nitride, aluminum nitride and yttria powders were pre-sintered at 1350 C and then studied by HT-XRD at temperatures between 1450 and 1580 C and nitrogen pressures of 0.11 MPa. The furnace was made from graphite coated with porous silicon nitride/silicon carbide. The coating prevented silicon carbide formation in the sample up to 1600 C. X-ray diffraction results show the formation of a Y_1_0Al_2Si_3O_1_8N_4 phase at 1350 C, which dissolved to form #alpha#-sialon and other phases at higher temperatures. The amounts of #alpha#-sialon formed are similar to the amounts reported by other authors. An empirical method was used for the calculation of activation energy for the silicon nitride to #alpha#-sialon ...
An International Workshop on Metrology for X-ray and Neutron Optics has been held March 16-17, 2000, at the Advanced Photon Source, Argonne National Laboratory, near Chicago, Illinois (USA). The workshop gathered engineers and scientists from both the U.S. and around the world to evaluate metrology instrumentation and methods used to characterize surface figure and finish for long grazing incidence optics used in beamlines at synchrotrons radiation sources. This two-day workshop was motivated by the rapid evolution in the performance of x-ray and neutron sources along with requirements in optics figure and finish. More specifically, the performance of future light sources, such as free-electron laser (FEL)-based x-ray sources, is being pushed to new limits in term of both brilliance and coherence. As a consequence, tolerances on surface figure and finish of the next generation of optics are expected to ...
Radionuclide X-ray fluorescence analysis (RXRFA), as a non-destructive method, relatively simple and allowing measurements to be carried out in situ, is an excellent tool in research on various objects of art. A range of artefacts have been investigated by our laboratory, in part for the purposes of history of art and in part as a basis for restoration works - medieval frescoes in some Czech castles and churches, metal sculptures and objects of applied art, paints and inks of old manuscripts, paintings. Some of these are among the most valuable monuments in the Czech cultural heritage. The contribution of the results of the tests to the investigation of their 'life story' and, in some cases, to their conservation, is not negligible. Later additions and repairs can be recognised, and materials and technologies that are close to their historic counterparts can be used in restoration work.
Radionuclide X-ray fluorescence analysis (RXRFA), as a non-destructive method, relatively simple and allowing measurements to be carried out in situ, is an excellent tool in research on various objects of art. A range of artefacts have been investigated by our laboratory, in part for the purposes of history of art and in part as a basis for restoration works - medieval frescoes in some Czech castles and churches, metal sculptures and objects of applied art, paints and inks of old manuscripts, paintings. Some of these are among the most valuable monuments in the Czech cultural heritage. The contribution of the results of the tests to the investigation of their 'life story' and, in some cases, to their conservation, is not negligible. Later additions and repairs can be recognised, and materials and technologies that are close to their historic counterparts can be used in restoration work.
Self-amplifying spontaneous radiation free-electron lasers, such as the LCLS or the European X-FEL, rely on the incoherent, spontaneous radiation as the seed for the amplifying process. Though this method overcomes the need for an external seed source one drawback is the incoherence of the effective seed signal. The FEL process allows for a natural growth of the coherence because the radiation phase information is spread out within the bunch due to slippage and diffraction of the radiation field. However, at short wavelengths this spreading is not sufficient to achieve complete coherence. In this presentation we report on the results of numerical simulations of the LCLS X-ray FEL. From the obtained radiation field distribution the coherence properties are extracted to help to characterize the FEL as a light source.
The development of a replacement to the conventional film based X-ray imaging technique is required for many reasons. One possible route for this is the use of a large area film of a suitable semiconductor overlaid on an amorphous silicon readout array. A suitable semiconductor exists in cadmium telluride and its tertiary alloy cadmium zinc telluride. In this thesis the spectroscopic characteristics of commercially available CZT X- and gamma-radiation detectors are established. The electronic, optical, electro-optic, structural and compositional properties of these detectors are then investigated. The attained data is used to infer a greater understanding for the carrier transport in a CZT radiation detector following the interaction of a high energy photon. Following this a method used to fabricate large area films of CdTe on a commercial scale is described. This is cathodic electrodeposition from an aqueous electrolyte. The theory and ...
As thin films become increasingly popular (for solar cells, LEDs, microelectronics, batteries), quantitative morphological information is needed to predict and optimize the film's electronic, optical and mechanical properties. This quantification can be obtained quickly and easily with X-ray diffraction using an area detector and synchrotron radiation in two simple geometries. In this paper, we describe a methodology for constructing complete pole figures for thin films with fiber texture (isotropic in-plane orientation). We demonstrate this technique on semicrystalline polymer films, self-assembled nanoparticle semiconductor films, and randomly-packed metallic nanoparticle films. This method can be immediately implemented to help understand the relationship between film processing and microstructure, enabling the development of better and less expensive electronic and optoelectronic devices.
Modern radiometric analytics demands a complex consideration of nuclear and electron shell processes, if more pretentious aims are envisaged. As an example the small variation of decay rates of radionuclides presents possibilities for information on chemical situations of decaying atoms. In principle this phenomenon is well known since many years, but now the situation is such that, e.g. in /sup 99m/Tc internal conversion, a full agreement of the difficult experiments and the respective theory was established. The secondary emission of X-rays as a consequence of high excitation of electron shells in combination with nuclear transitions supplies another example for a methodical progress of radiometry. Investigations on "5"1Cr as an electron capture nuclide have shown that chemically induced variations of the K/sub #alpha#/ to K/sub #beta#/ X-ray intensity ratio is at least qualitatively understood. (author).
A micropositioning stage for use with an x-ray microscope has been developed to scan samples over a 100 {mu}m{times}100-{mu}m area with a resolution of 100 A. The stage employs flexure hinges driven by piezoelectric actuators to achieve this high positioning accuracy. Due to the severe geometry of the hinges, stresses and deflections are determined (via finite element methods) to ensure a credible design. Since the stage is to be used in a stepping capacity, natural frequencies are computed to identify resonant conditions which could potentially cause excessive deflections. The finite element models show that the stage responds like a discrete lumped-mass system for the lower modes, and a continuous system with flexural characteristics for the higher modes.
SBA-15 supported nano-scaled copper oxide was synthesized by impregnation method via ultrasonic-assisted route. The removal test from gas mixture containing 0.1?vol.% hydrogen sulfide was carried out over this material at atmospheric conditions. The effects of the chemical nature of copper oxide and the textural properties of the material on removal capacity were studied. The materials before and after the removal test were analyzed by nitrogen adsorption, X-ray diffraction, Transmission Electron Microscope, X-ray photoelectron Spectroscopy, Fourier Transform Infrared Spectrometer and Inductive Coupled Plasma. The results showed that copper species are located predominantly in mesopore channels, existing as copper oxide nanoparticles. Mesopores are active sites for removal reaction. The ou...
From self-consistent band structure calculations using the 'augmented plane wave'(APW) method, the density of states can be decomposed into local partial (according to azimuthal quantum number l) components, the l-character densities. Within the APW formalism the intensity of X-ray emission spectra is determined by radial transition probabilities and l-character densities of such valence states, which reside inside the same atomic sphere as the core vacancy and whose quantum number l differs by +-1 from the one corresponding to the core state. By taking into account lifetime broadening of the core and valence states and also the instrumental broadening the computed spectra (non-metal K-, vanadium K- and Lsub(III)-spectra) agree well with experiment. (orig.).
Full text: Institute for Nuclear Research, Pitesti-Mioveni, Romania in direct cooperation with the National Institute for Laser, Plasma and Radiation Physics, Magurele, Bucharest studied and prepared for coating more than 1000 tiles made of Inconel with 7-9 #mu#m of beryllium for nuclear fusion applications at JET, Culham, UK. The principles of manufacturing processes using thermal evaporation and plasma ignited in pure metal vapors as well as by Thermionic Vacuum Arc (TVA) method and the properties of the Ni and Be coatings are presented. The prepared beryllium layers were characterized by scanning electron microscopy, transmission electron microscopy, X-ray diffraction, X-ray photoelectron spectroscopy and atomic force microscopy. (authors)
We present a fully automated method for three-dimensional (3D) elemental analysis demonstrated using a ceramic sample of chemistry (Ca)MgTiO_x. The specimen is serially sectioned by a focused ion beam (FIB) microscope, and energy-dispersive X-ray spectrometry (EDXS) is used for elemental analysis of each cross-section created. A 3D elemental model is reconstructed from the stack of two-dimensional (2D) data. This work concentrates on issues arising from process automation, the large sample volume of approximately 17x17x10 #mu#m"3, and the insulating nature of the specimen. A new routine for post-acquisition data correction of different drift effects is demonstrated. Furthermore, it is shown that EDXS data may be erroneous for specimens containing voids, and that back-scattered electron images have to be used to correct for these errors.
Fuji Computed Radiography (FCR) is a new system of digital radiography that is based on the latest computer technologies. We applied this FCR system to the X-ray diagnosis of the laryngeal disease. Twenty patients with various laryngeal diseases were evaluated by both FCR frontal tomography and conventional screen-film frontal tomography under the same exposure condition. Both tomograms were then compared on the subject of the clarity of delineation of laryngeal structures. As the result, FCR tomograms revealed the feature of the laryngeal lumen and cartilages more clearly than conventional tomograms. In addition, energy subtraction method, which is one of FCR image processing systems, was presented as a new technical procedure to extinguish cervical spine shadows in plain anteroposterior laryngeal X-photograph. We stress that FCR system is the suitable procedure for X-ray analysis of laryngeal diseases, especially in the ...
We present a detailed spectral analysis of point-like X-ray sources in the XMM-COSMOS field. Our sample of 135 sources only includes those that have more than 100 net counts in the 0.3-10 keV energy band and have been identified through optical spectroscopy. The majority of the sources are well described by a simple power-law model with either no absorption (76%) or a significant intrinsic, absorbing column (20%).As expected, the distribution of intrinsic absorbing column densities is markedly different between AGN with or without broad optical emission lines. We find within our sample four Type-2 QSOs candidates (L_X > 10^44 erg/s, N_H > 10^22 cm^-2), with a spectral energy distribution well reproduced by a composite Seyfert-2 spectrum, that demonstrates the strength of the wide field XMM/COSMOS survey to detect these rare and underrepresented sources.
Silver silica nanocomposites were obtained by the sol-gel technique using tetraethyl orthosilicate (TEOS) and silver nitrate (AgNO{sub 3}) as precursors. The silver nitrate concentration was varied for obtaining composites with different nanoparticle sizes. The structural and microstructural properties were determined by x-ray diffractometry (XRD), Fourier transform infrared spectroscopy (FTIR) and transmission electron microscopy (TEM). X-ray photoelectron spectroscopic (XPS) studies were done for determining the chemical states of silver in the silica matrix. For the lowest AgNO{sub 3} concentration, monodispersed and spherical Ag crystallites, with an average diameter of 5 nm, were obtained. Grain growth and an increase in size distribution was observed for higher concentrations. The occurrence of surface plasmon resonance (SPR) bands and their evolution in the size range 5-10 nm is studied. For decreasing nanoparticle size, a redshift and ...
The magnetic properties of as-grown Ga1-xMnxAs have been investigated by the systematic temperature and magnetic field dependent soft x-ray magnetic circular dichroism (XMCD) measurements in the Mn L2,3 absorption edge region. The XMCD intensity at high temperatures obeys the Curie-Weiss law, but residual spin magnetic moment appears already around 100 K, significantly above Curie temperature (Tc), suggesting that short-range ferromagnetic correlations are developed significantly above Tc. The high-field magnetic susceptibility becomes T-independent below TC, indicating that the AF interaction between the substitutional Mn (Mnsub and interstitial Mn (Mnint) ions, which becomes strong as the Mn concentration x increases, exists and that the amount of the Mnint affects Tc. The present experimental findings should give valuable insight into the inhomogeneous magnetic properties of many DMS's. (author)
The design of a gaging head for a portable radionuclide X-ray fluorescence analyzer is described. The gaging head is designed as a construction unit system which enables the application of lateral reflexion geometry as well as of coaxial geometry. It is designed so that adjustment from one geometry to the other is labour and time saving. The selection of characteristic radiation is performed by a couple of Ross' differential filters. These filters are prepared by a novel technique developed by our laboratory. The filter exchange is effected by the longitudinal move of the couple of filters encapsulated in a holder. The shift of the filters is controlled by means of a triggering mechanism situated in the body of the gaging head handle. This design makes is possible to handle the gaging head during measurements with one hand. A simple interchange of the absorption filter for the transmissive filter allows the operator to avoid any unwanted shift ...
The composition of sputter-deposited HgS films was determined by electron microprobe analysis. From the relative x-ray intensity as a function of film thickness, the depth of the ionizations that produce SK sub(..cap alpha..) and HgM sub(..cap alpha..) was found to be approximately 0.65 ..mu..m at an accelerating voltage of 15 kV. This value agreed well with a value calculated from Castaings' empirical law after absorption correction. The determination of film composition was limited to sufficiently thicker films than this critical value, usually 1 - 2 ..mu..m thick. The relation between the conposition of bulk standard determined by chemical analysis and the x-ray intensity ratio was used for the correction of film composition. The results showed that the crystal structure of HgS films was independent of the composition, i.e., the growth of metastable ..beta..-HgS films was not caused by the nonstoichiometry, and ...
The composition of sputter-deposited HgS films was determined by electron microprobe analysis. From the relative x-ray intensity as a function of film thickness, the depth of the ionizations that produce SK sub(#alpha#) and HgM sub(#alpha#) was found to be approximately 0.65 #mu#m at an accelerating voltage of 15 kV. This value agreed well with a value calculated from Castaings' empirical law after absorption correction. The determination of film composition was limited to sufficiently thicker films than this critical value, usually 1 - 2 #mu#m thick. The relation between the conposition of bulk standard determined by chemical analysis and the x-ray intensity ratio was used for the correction of film composition. The results showed that the crystal structure of HgS films was independent of the composition, i.e., the growth of metastable #betta#-HgS films was not caused by the nonstoichiometry, and that the composition of ...
Charge flow and valence/d-band behavior in ion-beam-mixed (IBM) Pd1-xAgx (x = 0.5-0.9) alloys have been studied by X-ray photoemission measurement of the valence bands and of core-level binding energy shifts and X-rayabsorption near-edge structure. We correlated the observed Ag 3d5/2 core-level shifts in these IBM alloys, relative to the elemental Ag, with the White Line area changes at the Pd and Ag L3-edge to investigate the charge redistribution at the Ag site. The results indicate that there is a decrease in sp-like conduction electron and a negligible change in the number of d-electrons at the Ag site upon alloying. These results are in line with our previous results in which Pd gains d-charges and loses sp-type charges. This electron redistribution due to hybridization in the alloy leads small net charge transfer from the Ag site to the Pd site in accordance with electronegativity predictions. This result is ...
For many centuries paper was the main material for recording cultural achievements all over the world. Paper is mostly made from cellulose with small amounts of organic and inorganic additives, which allow its identification and characterization and may also contribute to its degradation. Prior to 1850, paper was made entirely from rags, using hemp, flax and cotton fibres. After this period, due to the enormous increase in demand, wood pulp began to be commonly used as raw material, resulting in rapid degradation of paper. Spectroscopic techniques represent one of the most powerful tools to investigate the constituents of paper documents in order to establish its identification and its state of degradation. This review describes the application of selected spectroscopic techniques used for paper characterization and conservation. The spectroscopic techniques that have been used and will be reviewed include: Fourier-Transform Infrared spectroscopy, Raman spectroscopy, Nuclear Magnetic ...
A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. The authors established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging
During their life, intervertebral discs undergo degenerative changes which need not necessarily become lesions. Conventional X-rays do not provide information on the condition of the intervertebral discs, so MRT or CT are recommended as primary techniques as they are non-invasive. Invasive methods like myelography and especially discography should not be used unless a case is highly problematic. In infants with pains in the back, MRT should be carried out as early as possible as there is nearly always an organic cause. (orig.)
The structural variations of amorphous metals, such as Pd/sub 80/Si/sub 20/, with irradiation of helium ion, neutron, and gamma ray have been mainly pursued by the method of X-ray diffraction and thermal analysis. It should be noticed that the amorphous metals show a radiation resistance, that is, no remarkable structural changes under helium ion, neutron, and gamma ray irradiation.
In the present paper the progress of optimization of soft magnetic properties have been studied by applying different experimental techniques (magnetic measurements, electric measurements, X-ray analysis, and high-resolution electron microscopy observation). It has been shown that an increase in magnetic permeability after optimization annealing can be mainly attributed to annealing out of microvoids. (author)
The authors study the nonuniformity of a-Si:H films obtained by the method of vacuum condensation, with the help of x-ray small-angle scattering (SLS) and transmission electron microscopy. Films of hydrogenated amorphous silicon are greatest interest, because the electronic properties of this material can be controlled by doping. As a result of the compensation of the ruptured bonds, and possibly, effects of melting, the properties of such films are analogous to those of singlecrystalline silicon. XLS enables a quantitative determination of the prameters of the regions of low electron density (RLD) in such objects.
From the frequency of diagnostic radiologic examinations and their radiation dose delivered to the population the risk of cancer induction and genetic damage is calculated on the basis of the risk factors given by the ICRP. Thus 0.38 % and 3 % of the total mortality for cancer and leukemia, resp., can be attributed to X-ray diagnostics. Chest examinations alone result in 0.07-0.7 damages per 100,000 persons depending on the imaging technique applied. (author).
Elements Ti, Mn, Fe, Ni, Cu, Zn, Pb, Br, Rb and Sr were determined by the method of radionuclide X-ray fluorescence analysis with semiconductor detection in samples of Taraxacum officinale from various localities of Bratislava. The dependence of their content on the source and the degree of the air pollution was found out.
Elements Ti, Mn, Fe, Ni, Cu, Zn, Pb, Br, Rb and Sr were determined by the method of radionuclide X-ray fluorescence analysis with semiconductor detection in samples of Taraxacum officinale from various localities of Bratislava. The dependence of their content on the source and the degree of the air pollution was found out. (author).
Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A /sup 241/Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer.
Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A "2"4"1Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer. (E.S.).
The radial distribution function (RDF) derived from wide angle X-ray diffraction patterns gives additional information about the spatial distribution of atoms. Their radial distances and relative average coordination numbers can be calculated using appropriate mathematical procedures. 7 refs.
We determined the Na/K x-ray intensity ratio in frozen sections of myocardial tissues obtained at autopsy from patients who died from various causes, using electron probe analysis. We have been able to distinguish between the ischemically injured and normal cells. The method is simple, fast, and dependable even when the duration of ischemia is only 30 minutes.
Radionuclide X-ray fluorescence method with a Si/Li semiconductor detector and "2"3"8Pu exciting source was used in the determination of Cr, Fe, Ni, Cu, and Zn content in industrial wastewaters. Simultaneously, the effects of the wastewaters on activated sludge biocenose were evaluated. (author) 6 refs.; 1 fig.; 1 tab.
Peculiarities of metastable #beta#-solid solution decmposition in titanium alloy VT30 in the process of isothermal ageing in the range 500-650 deg C are investigated. Using the methods of transmittion electron microscopy, X-ray diffraction analysis, etc., it is shown that in the case of alloy quenching from the temperature below the point of complete polymorphous transformation (T_t_._t_.), as well as after warm rolling the course of subsequent decomposition of solid solution can be consierably complicated.
The nature of interaction of some boromagnesium minerals with water is studied, the main stages of interaction are established. The methods of thermo-gravimetric, X-ray phase and chemical analyses are applied to state intermediate and final phases of magnesium borate interaction with water. ''Preobrazhenskite'' - ''inderite'' paragenesis is established. The notion ''magnesium borate solubility'' is shown to be senseless.
A computerised curve-fitting method was developed to calculate the trapping parameters in LiF TLD-100 and LiF:Mg, Ti. After irradiation in a "6"0Co field and with Xrays emitted at different voltages the TL process is best described by first-order kinetics. A dependence of the trapping parameters on both the concentration of Mg and Ti and photon energy was detected. (author).
A central problem in diagnostic radiology is to compare a new X-ray picture with a previous picture and from this comparison be able to decide if anatomical changes have occurred in the patient or not. It is of primary interest that these pictures are identical in projection. If not it is difficult to decide with confidence if differences between the pictures are due to anatomical changes or differences in their projection geometry. In this thesis we present a non invasive method that makes it possible to find the relative changes in the projection geometry between the exposure of a previous picture and a new picture. The method presented is based on the projection slice theorem (central section theorem). Instead of an elaborate search for a single new picture a pre-planned set of pictures are exposed from a circular orbit above the patient. By using 3D Fourier transform techniques we are able to synthesize a new ...
The first step in the protection of the environment is the control of pollutant level in the components of the environment. The application is compared of radionuclide X-ray fluorescence analysis (RXFA) used for this purpose with polarographic and nuclear analytical techniques. The advantage of RXFA is its high sensitivity and selectivity, its low time and cost exactingness. The origins and development of RXFA are described. (Ha).
Hydrogen storage alloy composites La{sub 0.7}Mg{sub 0.25}Zr{sub 0.05}(Ni{sub 0.85}Co{sub 0.15}){sub 3.5}(x=0,5,10) were prepared by ball milling method. Their structures, morphologies and the hydrogen storage characteristics were intensively studied in the present work. It was found that the bulk of composites maintained the hexagonal C14 Laves phase structure after ball milling with additional La-Mg-based alloy for two hours. Scanning electron microscopy (SEM) observations revealed that the average size of Ti{sub 0.9}Zr{sub 0.2}Mn{sub 1.5}Cr{sub 0.3}V{sub 0.3} and La{sub 0.7}Mg{sub 0.25}Zr{sub 0.05}(Ni{sub 0.85}Co{sub 0.15}){sub 3.5} particles were reduced to several hundred nanometers after ball milling process. Energy dispersive X-ray spectrometer (EDS) patterns of the composites showed that the La{sub 0.7}Mg{sub 0.25}Zr{sub 0.05}(Ni{sub 0.85}Co{sub 0.15}){sub 3.5} phase was uniformly distributed on the surface of Ti{sub 0.9}Zr{sub ...
The patch and voxel methods are representative examples of the ways in which multi-slice images may be displayed three-dimensionally by means of computer-graphics. Each of them have advantages and disadvantages and they are mutually complementary. We have developed algorithms for a modified voxel method which incorporates the advantages of the patch methods. We have applied this to the three-dimensional image display of brain tumor with excellent results. The three-dimensional reconstructions used for clinical application in this study were derived from X-ray CT images.
The principle is described of a method using low-activity emitters as the primary radiation source for analysis. The selection of the radiation source and the detection methods including the assessment of the applicability of various radiation detectors are discussed. The benefits and the constraints of the method are considered. Practical examples are presented showing the application possibilities of the method for testing the thickness of bearing layers, piston ring coats, lead layers, etc. The possibility is shown of applying the rapid test for the composition of tungsten and chromium alloyed metal materials in testing complex systems. (J.K.).
Fuel irradiation leads to a swelling resulting from the formation of gaseous (Kr, Xe) or solid fission products which are found either in solution or as solid inclusions in the matrix. This phenomena has to be evaluated to be taken into account in fuel cladding Interaction. Fuel swelling was studied as a function of burn up by measuring the corresponding cell constant evolution by X-Ray diffraction. This study was realized on Mixed Oxide Fuels (MOX) irradiated in a Pressurized Water Reactor (PWR) at different burn-up for 3 initial Pu contents. Lattice parameter evolutions were followed as a function of burn-up for the irradiated fuel with and without an annealing thermal treatment. These experimental evolutions are compared to the theoretical evolutions calculated from the hard sphere model, using the fission product concentrations determined by the APPOLO computer code. Contribution of varying parameters influencing the unit cell value is discussed. Thermal ...
First-principles self-consistent band-structure calculations of potassium titanyl arsenate, KTiOAsO_4 (KTA), have been made using the full potential linearized augmented plane wave (FP-LAPW) method. Total and partial densities of states of the constituent atoms of KTA have been derived. The results obtained show that the valence band of KTA is dominated by contributions of the O 2p-like states, while the Ti 3d-like states are the main contributors into the conduction band of the compound. Additionally, the FP-LAPW calculations have revealed that potassium atoms are highly ionized in KTA. In the present work, the X-ray emission spectroscopy (XES) and X-ray photoelectron spectroscopy (XPS) methods were also employed to investigate experimentally the electronic structure of potassium titanyl arsenate. For the mentioned compound, the XES K Ll, Ti L#alpha#, As K#beta#_2 and O K#alpha# bands reflecting the ...
Circularly polarized X-rays produced by a diamond X-ray phase retarder of thickness 0.5 mm in the Laue transmission configuration have been used for recording X-ray magnetic circular dichroism...Full Text Available
A 'Laboratory of Quantitative Methods in Monument Research' is being built at the CTU Prague. Its primary orientation is the investigation of historic architecture, although other objects of art can also be investigated. In the first phase, two radiation methods are being established, but it is set up in such a way, that various other methods can readily be added in its future development. The radiation methods chosen for the initial development of the laboratory are: thermoluminescence dating and X-ray fluorescence analysis. The design of the automated TL-reader, built in our laboratories, is adjusted for the purpose of dating of historic brick architecture (which, of course, does not exclude applications for ceramics and other materials). The investigation of renaissance architecture in southern Bohemia and Moravia is under preparation as the first large campaign ...
A 'Laboratory of Quantitative Methods in Monument Research' is being built at the CTU Prague. Its primary orientation is the investigation of historic architecture, although other objects of art can also be investigated. In the first phase, two radiation methods are being established, but it is set up in such a way, that various other methods can readily be added in its future development. The radiation methods chosen for the initial development of the laboratory are: thermoluminescence dating and X-ray fluorescence analysis. The design of the automated TL-reader, built in our laboratories, is adjusted for the purpose of dating of historic brick architecture (which, of course, does not exclude applications for ceramics and other materials). The investigation of renaissance architecture in southern Bohemia and Moravia is under preparation as the first large campaign of this kind in ...
Magnetite nanoparticles with high self-heating capacity and low toxicity characteristics are a promising candidate for cancer hyperthermia treatment. In order to achieve minimum dosage to a patient, magnetic nanoparticles with high heating capacity are needed. In addition, the influence of physiological factors on the heat capacity of a material should be investigated in order to determine the feasibility. In this study, magnetite nanoparticles coated with lauric acid were prepared by co-precipitation of Fe{sup 3+}:Fe{sup 2+} in a ratio of 2:1, 5:3, 3:2, and 4:3, and the pH was controlled using NaOH. Structural and magnetization characterization by means of X-ray diffractometry (XRD) and a superconducting quantum interference device (SQUID) revealed that the main species was Fe{sub 3}O{sub 4} and further showed that most of the nanoparticles exhibited superparamagnetic properties. All of the magnetic nanoparticles showed a specific absorption ...
The Physikalisch-Technische Bundesanstalt (PTB), Germany's national metrology institute, developed an alignment strategy to specify elemental depth profiling in vertical sidewall layers on structured wafers. For this purpose, PTB's irradiation chamber for 200 mm and 300 mm silicon wafers was used to combine total-reflection X-ray fluorescence (TXRF) and grazing incidence XRF (GIXRF) techniques by employing monochromatized undulator radiation of the BESSY II electron storage ring. 3-D test structures were fabricated to develop an optimal alignment strategy allowing for depth profiling in such nanolayers. The test structures consisted of silicon bars with widths/spacings either in the {mu}m or in the nm range. In order to be able to differentiate the sidewalls more easily from the remainder of the structures, they were provided with an additional silicon nitride layer. Four structure types of different bar width and density parameters on two 200 mm ...
The Physikalisch-Technische Bundesanstalt (PTB), Germany's national metrology institute, developed an alignment strategy to specify elemental depth profiling in vertical sidewall layers on structured wafers. For this purpose, PTB's irradiation chamber for 200 mm and 300 mm silicon wafers was used to combine total-reflection X-ray fluorescence (TXRF) and grazing incidence XRF (GIXRF) techniques by employing monochromatized undulator radiation of the BESSY II electron storage ring. 3-D test structures were fabricated to develop an optimal alignment strategy allowing for depth profiling in such nanolayers. The test structures consisted of silicon bars with widths/spacings either in the ?m or in the nm range. In order to be able to differentiate the sidewalls more easily from the remainder of the structures, they were provided with an additional silicon nitride layer. Four structure types of different bar width and density parameters on two 200 mm silicon wafers were ...
The properties and kinetics of x-ray stars in globular clusters are described. Locations, configurations, star evolution, massive close binary systems, various mechanisms, and the x-ray burster properties are included. (JFP)
A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.
ASTROSAT, India's first dedicated astronomy satellite is slated for launch in 2007. The primary science objective of ASTROSAT is to explore the Universe using broad-band instruments covering optical, UV, soft X-ray and hard X-ray studies
The issue of beam-induced damage on diffractive hard X-ray optics is addressed. For this purpose a systematic study on the radiation damage induced by a high-power X-ray beam is carried out in both...Full Text Available
A novel difunctional acylhydrazone has been synthesized by the reaction of 5-methylisoxazole-4-carboyl hydrazine with benzaldehyde and characterized by X-ray crystallography and spectroscopy. The obtained results demonstrate the crystal belongs to triclinic, space group Formula Not Shown . Moreover, the spectroscopic properties were evaluated through density functional theory (DFT) and time-dependent density functional theory (TD DFT) calculations. The results reveal that UV-Vis absorption peaks at 194, 217.5 and 290.5nm are mainly attributed to (p, p)p*, partly (p, p)p* and partly pp*, and predominantly pp*, respectively, with intraligand charge-transfer transition (ILCT) character. The fluorescence emission peak at 485.96nm should be assigned to ILCT. In addition, the results of antibact...
The direct addition of nickel powder to the reaction mixtures of 1,3-dialkyl-4,5-dioxoimidazolidine-2-thione (1) with the thionation Lawesson reagent produces [Ni{sup II}(R{sub 2}timdt{sup -}){sub 2}] (R{sub 2}timdt = 1,3-dialkylmidazolidine-2,4,5-trithione). These complexes belong to a new class of nickel-dithiolenes, showing remarkably high absorption ({epsilon} {approx} 80 000 dm{sup 3} mol{sup -1} cm{sup -1}, {lambda} {approx} 1000 nm) in the near-infrared region (near-IR), accompanied by high photochemical stability that makes these complexes promising near-IR dyes.
LiNi{sub 0.8}Co{sub 0.2}O{sub 2} particles from high-power lithium-ion cells were examined to determine material changes that result from accelerated aging tests. X-rayabsorption spectroscopy (XAS) and transmission electron microscope (TEM) data indicated a Li{sub x}Ni{sub 1-x}O-type layer on the particle surfaces. The greater thickness on particles from high-power fade cells indicate that these surface layers are a significant contributor to cathode impedance rise observed during cell tests.
Experimentally, a feasibility study for adsorption and catalytic pyrolysis of spill oils on Cu/ZSM-5 for recycling of light oils has been conducted in the present work. The adsorption and pyrolysis of model compounds such as heptane, toluene, and diesel (to stimulate the spill oils) on Cu/ZSM-5 have been investigated on a continuous fixed-bed reactor. By component fitted X-rayabsorption near edge structural (XANES) spectroscopy, catalytic active species such as metallic copper (Cu) (77-84%) and Cu2O (6-7%) are found in the channels of ZSM-5 during pyrolysis of heptane or toluene. Pyrolysis of diesel effected by Cu/ZSM-5 yields gas (C1-C5) (32%) and light oil (68%) that can be used as auxiliary fuels.
The objective of materials research is the development of economical, safe and efficient synthesis routes that lead to the formation of a photocatalyst which is able to overcome performance problems related to particle size, crystallinity, or low surface area. Here, we report high-quality functional nanoparticles of calcium bismuth mixed oxide with 15nm nominal size corresponding to a specific surface area of 41m^2/g which were produced by single-step flame spray synthesis (FSS). The high temperature of the flame afforded creation of oxygen vacancies which were quantified by near edge X-rayabsorption fine structure (NEXAFS) spectra. These two parameters, developed active surface area and created in the flame oxygen vacancies, allowed to enhance the photocatalytic activity of calcium bismu...
Sintered glass-ceramics have been produced using municipal incinerator solid residues and glass cullet or an inert waste, from feldspars processing, as sintering aids. The capability of three different mixtures, either previously vitrified or not, to be sintered was investigated by means of linear shrinkage, water absorption and bulk density measurements, and by X-ray diffraction analysis and scanning electron microscopy observations. Particular attention has been addressed to the study of particle size effect on the sintering process. The conclusions that can be drawn from the experimental study are that the preliminary vitrification step is essential in order to obtain a dense sintered glass-ceramic product in the 850-1050 C temperature range developing silicate crystalline phases. The optimal powder particle size that confers a good densification degree was found to be < 45 {mu}m. (orig.)
The effect of the composition of multicomponent Zr-Ti-V-Mn-Cr-Ni alloys on their hydrogen-storage capacity and on the rate of electrosorption/desorption hydrogen was investigated under potentiodynamics as well as single-pulse and long-term galvanostatic conditions. The main characteristics of alloys and alloy electrodes were determined by their structural analysis by means of X-ray diffraction and scanning electron microscope, by specific surface area test and by determination of the hydrogen absorption/desorption isotherms in the gas/solid phase system. It was found that only the alloys with a manganese content below a threshold could be used as electrode materials for Ni-MH batteries, whereas the modification of the electrode material by micro-encapsulation of alloy particles should limit the dissolution of manganese from the electrode material in a strong alkaline solution. (orig.)
Cerium L_3 XANES (x-ray-absorption near-edge-structure) spectra were analyzed to separate Ce moment contributions and mixed valence (MV) in complex magnetic silicides CePd_2_-_xMn_xSi_2 (0#<=#x#<=#2). The Ce valence mixing does not vary linearly with x, but increases rapidly for x#>=#1.5. The associated moment collapse correlates with pronounced deviations of the unit-cell volume from Vegard law and the onset of structural instability. Reorientation of [001] Mn 3d antiferromagnetic order for x<2 appears to rapidly suppress the weak Ce valence mixing coexisting with antiferromagnetic order in CeMn_2Si_2.
Biosorption of lead from aqueous solutions by living and immobilized cell of C. freundii was examined as a function of metal concentration in a batch laboratory bioreactor. Lead concentrations were analyzed using Atomic Absorption Spectrophotometer (AAS). X-ray Energy Dispersion (EDX) analyses were made in order to determine the accumulation of lead on the cells and shell surfaces. Before and after the experiments the biomaterials and adsorbents were examined by Scanning Electron Microscopy (SEM). Biosorption was detected over a range of initial lead concentrations from 25{times}10{sup -3} to 200{times}10{sup -3} kg/m{sup 3}. 15 refs., 4 figs.
In the present study the optical properties of co-evaporated indium sulfide thin films are investigated. Before being optically characterized, the composition as well as the crystalline properties of the film have been checked with the help of energy dispersive spectroscopy (EDX) and X-Ray diffraction (XRD) analyses. The optical absorption coefficient ? of this indium sulfide film has been deduced from reflectivity R(?) and transmission T(?) measurements. The fit of the curve representing ?(h?) suggests that the ?-In2S3 has an indirect bandgap of 2.01?eV. Density functional theory (DFT) calculations are performed on this indium sulfide compound, using TB-LMTO code. Through these band structure investigations, an indirect bandgap is predicted as observed experimentally. The top of the valen...
The sampling is described for radionuclide X-ray fluorescence analysis. Aerosols are captured with various filter materials whose properties are summed up in the table. Fine dispersed solid and liquid particles and gaseous admixtures may be captured by bubbling air through a suitable absorption solution. The concentration of small amounts of impurities from large volumes of air is done by adsorbing impurities on surfactants, e.g., activated charcoal, silica gel, etc. Aerosols may be captured using an electrostatic precipitator and aerosol fractions may be separated with a cascade impactor. Water sampling differs by the water source, i.e., ground water, surface water, rain or waste water. Soil samples are taken by probes. (ES).
X-ray magnetic circular dichroism (XMCD) was used to probe the existence of induced magnetic moments in yttrium iron garnet (YIG) films in which yttrium is partly substituted with lanthanum, lutetium or bismuth. Spin polarization of the 4d states of yttrium and of the 5d states of lanthanum or lutetium was clearly demonstrated. Angular momentum resolved d-DOS of yttrium and lanthanun was shown to be split by the crystal field, the two resolved substructures having opposite magnetic polarization. The existence of a weak orbital moment involving the 6p states of bismuth was definitely established with the detection of a small XMCD signal at the Bi M{sub 1}-edge. Difference spectra also enhanced the visibility of subtle changes in the Fe K-edge XMCD spectra of YIG and {l_brace}Y, Bi{r_brace}IG films. Weak natural X-ray linear dichroism signatures were systematically observed with all iron garnet films and with a bulk YIG single crystal cut ...
Instrumental neutron activation analysis (INAA) and radionuclide X-ray fluorescence analysis (RXFA) were used for the determination of rare earth elements. For INAA, solution obtained by sample decomposition was dripped onto filter paper, enclosed and sealed into a polyethylene foil. The sample was activated in reactor WWR-S over a period of 4 to 6 hours with a neutron fluence of 10"1"3cm"-"2. Gamma radiation measurement was carried out with a planar and a coaxial HP-Ge detector in three decay periods. La, Ce, Nd, Sm, Eu, Gd, Tb, Ho, Tm, Yb and Lu were determined. The advantage of the method is its accuracy and high sensitivity, the disadvantage is the time-consuming analysis. The RXFA method was used as a rapid and operative method for the analysis of loose ore samples, aqueous and organic solutions of rare earth elements. For exciting X-ray radiation, "2"4"1Am was used and the ...
X-ray diffraction enhanced imaging (DEI) is applied to inspect internal structures of weakly absorbing low-Z sample. How to extract phase information from raw images measured in different positions of rocking curve is the key problem of DEI. In this paper, we present an effective extraction method called polynomial curve fitting method, in order to extract accurate information angular in a fast speed. It is com- pared with the existing methods such as multiple-images statistical method and Gaussian curve fitting method. The experiments results on a plastic cylinder and a black ant at the Beijing Synchrotron Radiation Facility prove that the polynomial curve fitting method can obtain most approximate refraction-angle values and its computation speed is 10 times faster than the Gaussian curve fitting method. (authors)
High interelectrode voltage peaks have been observed simultaneously with the emission of hard X-ray bursts from a flash X-ray tube. The magnitude of the voltage peaks may exceed twice the initial charging voltage. It has also been observed that the discharge emits bursts of X-and P-band microwaves radiation which are coincident with the emission of the hard X-ray bursts. The results indicate that the microwaves and X-rays have a common origin in discharge plasma movements and an acceleration model for electrons in the plasma is presented as one possible explanation of the observed phenomena.
Methods of X-ray diffraction and transmission electron microscopy were used to study the microstructure of dispersion-strengthened Cu-Al2O3 nanocomposites obtained by the method of simultaneous deposition of Cu and Al2O3 from the vapor phase. The effect of the size of particles of the oxide (Al2O3) and of their content on the electrical resistance of the composite has been considered. The results obtained make it possible to suppose that the main structural factor that determines the electrical resistance of the composite are nanodispersed particles of Al2O3 with a size of less than 20 nm.
HgTe rod-shape composed of crystalline particles has been prepared by a hydrothermal method, and characterized by means of X-ray powder diffraction (XRD), scanning electron microscopy (SEM), and transition electron microscopy (TEM). The effects of capping agents, reductants, reaction temperatures, and reaction times on crystal structures and shapes of HgTe have been investigated. The results showed that the CTAB as capping agent plays a crucial role in the hydrothermal process. The synthesis procedure is simple and uses less toxic reagents than the previously reported methods.
Water-soluble, ethanol-insoluble extracts prepared from several medicinal herbs of the Araliaceae and other families were tested for their radioprotective activity by either measuring 30 days survival rates (a commonly applied method) or counting the thrombocytes 14 days after irradiation (an improved method) in mice. The extracts were i.p. injected once within 4 min after the whole body X-ray irradiation. Of 12 materials examined, Aralia elata, Angelica acutiloba and Morus bombysis seemed to be good starting materials for preparing radioprotective substance(s) because of their relatively high specific activity and high yields of the extracts. (author).
The purpose of this work is to present a comprehensive, instructive analysis of the basis of radionuclide XRFA, to describe methods of sample preparation for environmental analysis and to make the reader more familiar with the procedures, methods and instrumentation of radionuclide XRFA used in this field. This book discusses the use of radionuclide XRFA for solving analytical problems of the environment and information is presented concerning the current state of research and use of radionuclide XRFA in this significant area. The present volume will serve as a basic source of data and also as a laboratory handbook. refs.; figs.; tabs.
AlN nanocrystalline layers and superstructures are used in the modern optoelectronic technology as reflecting mirrors in semiconductor layers. In the present work the properties of AlN films prepared by sputtering methods from an AlN target in reactive Ar + N plasma were investigated. The characterization was performed with HRTEM, SEM, glancing angle XRD and RBS methods. The present measurements confirmed the polycrystalline structure of AlN layers and enabled the evaluation of their grain size. The roughness and thickness of the layers were additionally determined by ellipsometric and profilometric measurements. (author)
The use of the method is described on powder samples before and after sintering with a La content of up to 1%. For excitation of the K series of La a /sup 241/Am source with an activity of 1.11 GBq was used. The obtained results showed that the method is sufficiently accurate (error 7%) at a short period of measurement (100 s). It gives satisfactory results even in the comparison of the experimental relative count rate and the theoretically calculated value despite the fact that the analytical signal comes from the sample surface.
The use of the method is described on powder samples before and after sintering with an La content of up to 1%. For excitation of the K series of La a _2_4_1Am source with an activity of 1.11 GBq was used. The obtained results showed that the method is sufficiently accurate (error 7%) at a short period of measurement (100 s). It gives satisfactory results even in the comparison of the experimental relative count rate and the theoretically calculated value despite the fact that the analytical signal comes from the sample surface. (Ha).
For the first time, rheological phase method, a simple and effective route, is applied to synthesize novel cathode material LiCoPO{sub 4}. X-ray diffraction spectrometer (XRD), X-ray photoelectron spectrometer (XPS), transmission electron microscope (TEM) and electrochemical impedance spectroscopy (EIS) are taken to investigate this material, respectively. XRD figure shows that the rheological sample is better crystallized than the solid-state one. XPS result of the rheological sample exhibits that the valence of Co is 2+. TEM images show that better dispersed particles with smaller size can be formed by rheological method comparing to the solid-state route. Charge-discharge test is carried out in the range of 3.0-5.0 V at 0.2 mA cm{sup -2}. The initial discharge capacity for rheological phase and solid-state powder is 71.5 and 30.9 mAh g{sup -1}, respectively. The better electrochemical property should ...
For the first time, rheological phase method, a simple and effective route, is applied to synthesize novel cathode material LiCoPO4. X-ray diffraction spectrometer (XRD), X-ray photoelectron spectrometer (XPS), transmission electron microscope (TEM) and electrochemical impedance spectroscopy (EIS) are taken to investigate this material, respectively. XRD figure shows that the rheological sample is better crystallized than the solid-state one. XPS result of the rheological sample exhibits that the valence of Co is 2+. TEM images show that better dispersed particles with smaller size can be formed by rheological method comparing to the solid-state route. Charge-discharge test is carried out in the range of 3.0-5.0 V at 0.2 mA cm-2. The initial discharge capacity for rheological phase and solid-state powder is 71.5 and 30.9 mAh g-1, respectively. The better electrochemical property should be ascribed to ...
The task of designing high performance X-ray optical systems requires the development of sophisticated X-ray scattering calculations based on rigorous information about the optics. One of the most insightful approaches to these calculations is based on the power spectral density (PSD) distribution of the surface height. The major problem of measurement of a PSD distribution with an interferometric and/or atomic force microscope arises due to the unknown Modulation Transfer Function (MTF) of the instruments. The MTF characterizes the perturbation of the PSD distribution at higher spatial frequencies. Here, we describe a new method and dedicated test surfaces for calibration of the MTF of a microscope. The method is based on use of a specially designed Binary Pseudo-random (BPR) grating. Comparison of a theoretically calculated PSD spectrum of a BPR grating with a spectrum measured with the grating ...
The optical absorption spectra of the rhombohedral DyOF were measured at selected temperatures between 9 and 300 K. The emission spectra of the Dy{sup 3+} ion in the LaOF and GdOF matrices were obtained at 77 K and room temperature. The energy level scheme of Dy{sup 3+} (4f{sup 9} electron configuration) was simulated with a Hamiltonian of 20 parameters. The diagonalization of the energy matrices including simultaneously the free ion and crystal field (c.f.) interactions was carried out for the C{sub 3{upsilon}} point symmetry of the RE{sup 3+} site. Good correlation with an rms deviation of 17 cm{sup -1} was obtained between the experimental and calculated energy level schemes of 153 Kramers doublets. The c.f. parameters show only slight distortion from O{sub h} symmetry. A comparison to Pr{sup 3+} (4f{sup 2}), Nd{sup 3+} (4f{sup 3}), Sm{sup 3+} (4f{sup 5}), Eu{sup 3+} (4f{sup 6}), and Tb{sup 3+} (4f{sup 8} electron configuration) in other REOF matrices showed ...
Carbon-14 was analysed by direct absorption of carbon dioxide on the mixture of organic amine compound and scintillation cocktail then counted by low level liquid scintillation counter. This method can be applied for radiocarbon dating. In this study, the effects of carbon dioxide absorption, and counting efficiency were investigated using various commercial available cocktail. It was found that permafluor V and Ready Gel showed the highest carbon dioxide absorption whereas the Permafluor V showed the highest counting efficiency
The effect of resonance, observed in X-ray waveguide layered structures in a characteristic way influences the scattering properties of the films. It is well known that the resonant region in the reflectivity shows a series of minima, usually very deep and extremely narrow. The positions and depths of the minima depend only on X-ray waveguide and quasi X-ray waveguide film structural properties, on the X-ray wavelength and on the incident beam divergence. In the present work we propose and discuss the application of the X-ray waveguide and quasi X-ray waveguide film structures as a tools to experimental evaluation of some quantities related to X-ray reflectometric and diffractometric measurements, like the beam divergence, wavelength, or angular distance. Examples of application of X-ray waveguide as an excellent tool ...
We propose a new method to measure the metallicity of Type Ia supernova progenitors using Mn and Cr lines in the X-ray spectra of young supernova remnants. We show that the Mn to Cr mass ratio in Type Ia supernova ejecta is tightly correlated with the initial metallicity of the progenitor, as determined by the neutron excess of the white dwarf material before thermonuclear runaway. We use this correlation, together with the flux of the Cr and Mn Kalpha X-ray lines in the Tycho supernova remnant recently detected by Suzaku (Tamagawa et al. 2008) to derive a metallicity of log(Z) = -1.32 (+0.67,-0.33) for the progenitor of this supernova, which corresponds to log(Z/Zsun)= 0.60 (+0.31,-0.60) according to the latest determination of the solar metallicity by Asplund et al. (2005). The uncertainty in the measurement is large, but metallicities much smaller than the solar value can be confidently discarded. We discuss the ...
Here in the present paper, we report on growth of stoichiometric and nonstoichiometric nanostructured heterojunction solar cell of CdS/CuInSXSe2-X varying X from 0 to 2 in the interval of 0.5 using cost effective, simple, chemical ion exchange method at room temperature on ITO glass substrate. The as-grown varying composition solar cells annealed at 200degreeC in air and characterized for structural, compositional, optical and illumination studies. The X-ray diffraction pattern obtained from CdS/CuInSXSe2-X solar cell confirms the formation of CuInSe2, CuInS0.5Se1.5, CuInS1Se1, CuInS1.5Se0.5 and CuInS2 phases having tetragonal structure with varying crystallite size from 19, 19.37, 28, 33 and 20nm respectively. The energy dispersive X-ray analysis (EDAX) confirms the expected elemental com...
Monodisperse europium-activated titania hollow phosphors had been synthesized by a facile one-pot hydrothermal method using carbon spheres as hard templates. Samples were characterized by X-ray powder diffraction, transmission electron microscopy, X-ray photoelectron spectroscopy, energy dispersive spectrometer and photoluminescence spectrum. The strongest emission intensity was observed with TiO2:Eu0.2 hollow spheres and TiO2:Eu0.2 hollow spheres calcining at 550^oC. Moreover, the strongest excitation of TiO2:Eu0.2 hollow spheres transferred from 400 to 500^oC and the effective nonradiative energy transfer from the TiO2 hollow spheres host matrix to Eu^3^+ ions crystal field states was realized due to changes of crystalline field in the environment around Eu^3^+ ions occupying Ti^4^+ site...
We propose and demonstrate a facile room-temperature synthetic method for obtaining water-soluble magnetic Fe3O4 nanoparticles (NPs) by combining the in situ synthesis and decomposition of a magnetic polymer hydrogel. The Fe3O4 NPs with average diameters of 6.3-8.3nm were synthesized in a cross-linked polyacrylamide (PAAm) hydrogel by coprecipitating iron ions. The decomposition of the magnetic polymer hydrogel by an aqueous solution of sodium hydroxide led to the transfer of Fe3O4 NPs into the aqueous medium. The NPs can be dispersed stably in water for more than three months. The Fe3O4 NPs were characterized by X-ray photoelectron spectra (XPS), X-ray powder diffraction (XRD), transmission electron microscope (TEM), and Fourier transform infrared spectroscopy (FT-IR). The saturation magn...
The development of leukemia and thyroid cancer is characterized by activation of the abl oncogene and ret oncogene, respectively. In order to clarify the relationship between these gene aberrations and radiation, the pro-myelogenous leukemia-derived cell line HL60 and the thyroid cancer-derived cell line 8505C, were irradiated in vitro with 100Gy of X-rays. RNA was then extracted from 10"8 cells of the respective cell lines and examined by the reverse transcription PCR method for rearrangements of abl and ret genes. Five kinds of positive bands were observed in the HL-60 cells irradiated with 100Gy of X-ray. Similarly, six positive bands were also observed in the 8505C cells irradiated with 100Gy. In vitro X-irradiation activation of oncogenes found in radiation induced cancers imply that gene rearrangement by X-rays is involved in the development of malignant tumors. Furthermore, in an experiment to ...
Free Electron Laser (FEL) with the wide wavelength tunability has been developed and used for various applications. The FEL gives high efficiency for the photo-induced ablation when the laser is tuned to an absorption maximum of the target. The FEL was tuned to 9.4 #mu#m, which is an absorption maximum of phosphoric acid ion, a known major component of dentine. The FEL pulse length was several ps. The average output power was varied from 5 to 20 mW by filters. The change of irradiated dentine surface was analyzed by mass spectroscopy and Energy Dispersive X-ray (EDX) spectroscopy. Positive ions which correspond to Na"+, CO_3"+ and many phosphoric acid ions were measured. It was found that atomic ratio of P/Ca had reduced from 0.65-0.60. The atomic ratio of P/Ca, however had not changed with irradiation by Er:YAG laser (2.9 #mu#m), or CO_2 laser (10.6 #mu#m). These results indicate the selective ablation of phosphoric acid ...
Absorption spectra of the CT bands of I_2 complexes with Et_2O, Et_2S, and Et_2Se in heptane have been measured up to 4400 bar at 25"0C. The equilibrium constants and the volume changes accompanying complex formation, and the molar extinction coefficients and absorption maxima have been estimated. The volume changes were comparable with those estimated by the visible I_2 bands and by the X-ray data of the I_2 complexes in the crystalline state. In the CT bands of Et_2S-I_2 and Et_2Se-I_2 complexes inversion of shift from red to blue has been observed with increasing pressure though the CT band of Et_2O-I_2 complex shifted only through red. This inversion appears to be characteristic of the strong CT complex. Enhancement of the molar extinction coefficient of the CT band has been found with increasing pressure suggesting enhancement of the CT interaction between I_2 and the n-donor. (author).
The nine papers presented at this conference cover the following topics: the systematization, condensed description, and prediction of sets of anion exchange extraction constants on the basis of their statistical computer treatment; characteristics and uses of solid extractants containing D2EHPA and TBP for separating the transplutonium elements; enrichment of americium 242m and americium 242 by the Szilard-Chalmers method; an x-ray diffraction pattern analysis for transplutonium compounds; the radiation chemistry of americium; and the effects of alpha irradiation on the behavior of americium in perchlorate solutions.
Central penetrating excisional wounds were made in the corneas of 12 rabbits and 10 trout. The scar tissue and the surrounding cornea were compared using a new method for assessing inorganic elements in the cornea: the scanning electron microscopy and energy dispersive analysis of x-ray (EDAX). Semiquantitative determination of inorganic elements within the range of atomic numbers 9-93 in the periodic system was performed, comparing the relative concentration of those elements in the scar tissue to the surrounding cornea. Results showed that calcium was the only element higher in the healing wound than in the surrounding cornea.
In the Wajima lung cancer screening program conducted under the auspices of Kanazawa University Hospital, Fuji Computed Radiography (FCR) was utilized in a new chest radiography trial. The results of the screening program are that the necessity of repeat examinations due to poor image quality are less common and the method enables detection of small pulmonary nodular shadows which are possibly candidates for surgery. Oblique chest X-ray with FCR is remarkably effective for the detection and the identification of small lesions. However, the disadvantage of slow processing and high cost must be fully satisfied if FCR is to become a new imaging modality for mass screening.
In the Wajima lung cancer screening program conducted under the auspices of Kanazawa University Hospital, Fuji Computed Radiography (FCR) was utilized in a new chest radiography trial. The results of the screening program are that the necessity of repeat examinations due to poor image quality are less common and the method enables detection of small pulmonary nodular shadows which are possibly candidates for surgery. Oblique chest X-ray with FCR is remarkably effective for the detection and the identification of small lesions. However, the disadvantage of slow processing and high cost must be fully satisfied if FCR is to become a new imaging modality for mass screening. (author).
By the methods of small-angle X-ray scattering and translucent electron microscopy the existence of inhomogeneity of electron density in hydrogenated films of amorphous silicon is confirmed. The decreased density regions are extended and form a branched network of channels oriented mostly by the normal direction to the films surface. The typical size of the decreased density regions network constitutes 10 nm in the 100-800 nm films thickness range. The increase of hydrogen total partial pressure in gas mixture in case of films growth results at first in the decrease of extension of these regions and than to micropores generation in the network nodal points of the decreased electron density regions.
The additional error in measurement of the thickness of Kh18N10T steel for possible changes in composition with an energy of the photons of ionizing radiation of 10-80 keV was evaluated. The desirability of use of a type REIS-I x-ray emitter in measurement of the thickness of steel up to 1 mm is shown. The instrument provides measurement of the thickness of steel in the 0.1-1.0 mm range with a reproducibility of the results with an error not exceeding 0.5-1.0%. The measurement error with corrugations characteristic of bellows does not exceed 5%.
The mono- and intramolecular cation-radicals (CR) reactions of diethylmercury in the CFCl_3, CFCl_2CF_2Cl matrices and CF_2BrCF_2Br and CFCl_3 freons vitrified mixture (1:1) were studied through the EPR method. Formation of radical products of transformations of the initial CR diethylmercury (X-ray radiation dose - 100-200 Gy at the temperature of 293 K) was studied through the spin trap of 2.4.6 - tri-tret-butylnitrosebenzene.
We describe a 16-month-old boy presenting with stridor and fever. The chest X-ray suggested inhalation of a foreign body but here was no history of this. A high spot a T_1-weighted chest MRI was due to a peanut which was seen to have moved from the right main bronchus to the left inferior bronchus, between the two MRI studies. MRI can provide information on position and size of the peanut, the conditons of the surrounding tissues and may be also useful in treatment. We consider MRI to be a valuable new method for the diagnosis of peanut inhalation. (orig./GDG).
Crystal structure of monoclinic telluric acid ammonium phosphate (TAAP) has been studied by an X-ray diffraction method in the paraelectric phase at 333 K and in the ferroelectric phase at room temperature. It is confirmed that the space group in the paraelectric phase is P2/n. Comparison of the results between the two temperatures suggests that the plane which is made by the PO{sub 4} tetrahedron linked by hydrogen bonds has an important role for the ferroelectric phase transition. This plane is almost parallel to the direction of spontaneous polarization.
This was a project to investigate the crystal chemistry of OH and H{sub 2}O substitution in silicate minerals by use of X-ray and neutron diffraction methods combined with IR spectroscopy and to interpret and generalize the results using an electrostatic model for these mineral structures. Using these data together with published H position data electrostatic parameters for H sites were calculated from a simple electrostatic model. The data were then used to refine the model for incorporation of H into the wadsleyite structure. This has led to recent work on the synthesis and characterization of hydrous wadsleyites.
Examples are given of reference materials for radionuclide X-ray fluorescence analysis (RXFA) of the environment processed by the National Bureau of Standards and the IAEA. Methods are described used for preparing standard materials for RXFA. For determining air pollutants the sample is prepared by dry or wet mineralization. Water samples have to be preserved prior to analysis. Insoluble components are separated by filtration or centrifugation. Biological materials must be dehydrated and homogenized. Samples of soil, sludges, sediments and solid wastes will sometimes have to be converted into a solution in some cases a leachate will have to be obtained. (ES).
The most important commercialized methods of attenuation correction in SPECT are based on attenuation coefficient map from a transmission imaging method. The transmission imaging system can be the linear source of radioelement or a X-ray CT system. The image of transmission imaging system is not useful unless to replacement of the attenuation coefficient or CT number with the attenuation coefficient in SPECT energy. In this paper we essay to evaluate the validity and estimate the error of the most used method of this transformation. The final result shows that the methods which use a linear or multi-linear curve accept a error in their estimation. The value of mA is not important but the patient thickness is very important and it can introduce a error more than 10 percent in the final result.
Monochromator stabilization (MOSTAB) is a feedback control system to stabilize an x-ray beam of synchrotron radiation. It applies a feedback voltage to a piezo electric transducer attached to a double-crystal monochromator. We developed MOSTAB modules and examined their performances using SPring-8 beamlines. The x-ray beam position stabilization using MOSTAB was realized simultaneously with the x-ray beam intensity stabilization. As an example of its application, we performed EXAFS measurement with MOSTAB. (author)
Global angular momentum balance suggests that the neutron stars in Be/X-ray binaries are not spinning in equilibrium. This requires an X-ray lifetime ''approx <'' 10"5 yr, and suggests that there are many 'dead' Be/X-ray binaries in the Galaxy. Some of these may be turned up as millisecond radio pulsars with Be star companions. (author).
X-ray emission spectroscopy (XES) and X-ray photoelectron spectroscopy (XPS) methods were employed in the present paper to investigate the electronic structure of face-centred cubic (fcc) molybdenum dioxide, fcc-MoO_2. For the mentioned compound, the XES O K#alpha# and Mo L#beta#_2_,_1_5 bands reflecting the valence O p- and Mo s,d-like states, respectively, were derived and compared on a common energy scale with the XPS valence-band spectrum. For comparison, the similar experimental studies of the electronic structure were made for a usual orthorhombic form of molybdenum trioxide, MoO_3. Band-structure calculations of fcc-MoO_2 were made using the full potential linearized augmented plane wave (FP-LAPW) method. A rather good agreement of the experimental XES and XPS results and the theoretical FP-LAPW data for the electronic properties of fcc-MoO_2 has been achieved in the present paper. A new ...
Phase relations in the ternary system Ce-Pd-Si have been established for the isothermal section at 800degreeC based on X-ray powder diffraction and EMPA techniques on about 130 alloys, which were prepared by arc-melting under argon or powder reaction sintering. Eighteen ternary compounds have been observed to participate in the phase equilibria at 800degreeC. Atom order was determined by direct methods from X-ray single-crystal counter data for the crystal structures of t8-Ce3Pd4Si4 (U3Ni4Si4-type, Immm; a=0.41618(1), b=0.42640(1), c=2.45744(7)nm), t16-Ce2Pd14Si (own structure type, P4/nmm; a=0.88832(2), c=0.69600(2)nm) and also for t18-CePd1-xSix (x=0.07; FeB-type, Pnma; a=0.74422(5), b=0.45548(3), c=0.58569(4)nm). Rietveld refinements established the atom arrangement in the structures of...
Radionuclide X-ray fluorescence analysis and fast neutron activation analysis were used for the determination of chromium. The excitation source for X-ray fluorescence analysis was a ring-shaped "2"4"1Am source with an activity of 18.5x10"9 Bq. SYNPOR filters of 35 mm in diameter were used for the measurement. The 5.414 keV Cr peak was measured with a Si(Li) detector. The sensitivity was 0.05 mg for a period of measurement of 1000 s. A neutron generator with an emission of 10"9 s"-"1 was used as the source of fast neutrons. "5"2V and "5"3V, the products of nuclear reaction with Cr, were measured gamma spectrometrically with a Ge(Li) detector. The sensitivity for Cr is 0.015 mg, in the presence of Mn which causes interference the sensitivity is a mere 0.075 mg. The mentioned methods were used to determine total Cr and Cr(VI) in welding aerosols. It was found that the most toxic form, i.e., Cr(VI), is released during manual ...
Qualitative and quantitative methods have been developed to relate phosphate/UO{sub 2} interactions and U dissolution, in vitro, in a medium containing 0 or 10 mM phosphate concentrations at pH 5. This was performed by Energy Dispersive Xray Spectrometry (EDS) at 200 kV on entire particles and by fluorimetric measurement. The U dissolution rate was larger in a medium without phosphate than in a medium containing 10 mM phosphate. During the first day, the initial U dissolution involved 80.55% and 91.13% of the powder in media with and without phosphate respectively. From 5 to 15 d after beginning the assay, the dissolution half-times were longer than 92 d and 22 d for media with and without phosphate. EDS analyses have shown a constant P/U Xray intensity ratio for reference U{sub 2}O(PO{sub 4}){sub 2} for the same range of particle diameter. A gradual increase of this ratio was ...
Diagnostic x-ray spectrometry, a method based on x-ray fluorescence analysis, was used for noninvasive determination of iron and zinc in two distinct skin areas, representing predominantly dermal and epidermal tissues, in 56 patients with beta-thalassemia major and intermedia. The mean iron levels in the skin of patients with beta-thalassemia major and intermedia were elevated by greater than 200% and greater than 50%, respectively, compared with control values. The zinc levels of both skin areas examined were within the normal range. The data indicate that the rate and number of blood transfusions, which correlated well with serum ferritin levels (r . 0.8), are not the only factors that determine the amount of iron deposition in the skin (r less than 0.6). Other sources of iron intake contribute to the total iron load in the tissues, particularly in patients who are not given multiple transfusions. The noninvasive ...
Heterogeneous gasless reactive systems, including high-energy density metal-nonmetal compositions, have seen increasing study due to their various applications. However, owing to their high reaction temperature, short reaction time, and small scale of heterogeneity, investigation of their reaction mechanisms and kinetics is very difficult. In this study, microstructural changes and the kinetics of product layer growth in the W-Si system was investigated using a high-speed x-ray phase-contrast imaging technique. Using the Advanced Photon Source of Argonne National Laboratory, this method allowed direct imaging of irreversible reactions in the W-Si reactive system at frame rates up to 36 000 frames per second with 4 {mu}s exposure and spatial resolution of 10 {mu}m. Details of the Si melt and reactions between W and Si, that are unable to be viewed with visible-light imaging, were revealed. These include processes such as the initiation of ...
Heterogeneous gasless reactive systems, including high-energy density metal-nonmetal compositions, have seen increasing study due to their various applications. However, owing to their high reaction temperature, short reaction time, and small scale of heterogeneity, investigation of their reaction mechanisms and kinetics is very difficult. In this study, microstructural changes and the kinetics of product layer growth in the W-Si system was investigated using a high-speed x-ray phase-contrast imaging technique. Using the Advanced Photon Source of Argonne National Laboratory, this method allowed direct imaging of irreversible reactions in the W-Si reactive system at frame rates up to 36 000 frames per second with 4 #mu#s exposure and spatial resolution of 10 #mu#m. Details of the Si melt and reactions between W and Si, that are unable to be viewed with visible-light imaging, were revealed. These include processes such as the initiation of ...
Context. The I(15.01 A)/I(16.78 A) emission line intensity ratio in Fe XVII has been reported to deviate from its theoretical value in solar and stellar X-ray spectra. This is attributed to opacity in the 15.01 A line, leading to a reduction in its intensity, and was interpreted in terms of a geometry in which the emitters and absorbers are spatially distinct. Aims. We study the I(15.01 A)/I(16.78 A) intensity ratio for the active cool dwarf EV Lac, in both flare and quiescent spectra. Methods. The observations were obtained with the Reflection Grating Spectrometer on the XMM-Newton satellite. The emission measure distribution versus temperature reconstruction technique is used for our analysis. Results. We find that the 15.01 A line exhibits a significant enhancement in intensity over the optically thin value. To our knowledge, this is the first time that such an enhancement has been detected on such a sound statistical basis. We interpret ...
Correct ortopedic therapy for traumas of the cervical rachis requires perfect knowledge of the spatial balance of the fracture focus. The authors belive Computed Tomography (CT) to be the most suitable, and often indispensable, method for this purpose. Twenty-four patients were examined for traumatic pathology of the cervical rachis. In 7 cases with clinically minor traumas, the negative outcome of the traditional traumas, the negative outcome of the traditional exam was considered reliable and sufficient for therapeutic purposes. The extant 17 patients were examined also by means of CT, either to better dermine the characteristics of skeletal lesions already ascertained with traditional techniques or to asses the presence of clinically-suspected osteo-articular lesions, even with negative conventional X-rays. For 9 of these patients orthopedic treatment was considered sufficient, whereas 8 patients underwent surgery and were subsequently ...
Structural variations in 39-MeV alpha-particle irradiated (Tsub(irr) = 60 deg C) polycrystalline molybdenum during post-irradiation annealing were studied by X-ray and TEM methods. Despite the high density of irradiation induced defects in the structure of the specimen X-ray measurements showed zero relative lattice parameter change after an irradiation dose of 1.1 x 10"-_2 dpa. However, during the annealing #delta#a/a was changed in the positive range, exhibiting two peaks - at 100 and 300 deg C - whereas the damage structure detected by TEM indicated no changes. Analysis of the results leads to the conclusion that in the range 100 to 250 deg C migration of isolated vacancies and their annihilation at interstitial clusters as well as possible formation of new vacancy clusters occur. The second peak on the #delta#a/a temperature dependence curve is related to the transformation (probably, thermal disintegration) of vacancy ...
A magnetic core/shell Fe3O4/FeMnOx catalyst was prepared by a simple oxidation-precipitation method. The catalyst was characterized by X-ray diffraction, transmission electron microscope, X-ray photoelectron spectroscopy, Fourier transform infrared spectroscopy, thermogravimetric analysis and cyclic voltammetry. The characterization studies verified that Fe3O4 core was coated with a layer of Fe-Mn oxide. The Fe3O4/FeMnOx was found to be an effective and stable heterogeneous catalyst for the discoloration of methylene blue (MB) in aqueous solution by H2O2. The high catalytic activity is due to the FeMnOx shell, which not only increased the surface hydroxyl groups, but also enhanced the interfacial electron transfer. The discoloration of MB could be due to the decomposition of H2O2 into ?OH ...
In this project, nanocrystalline SnO2 powders were successfully prepared by (a) citrate sol-gel and (b) direct precipitation methods. Powders were characterized using thermal analysis techniques (DTA-TG-DSC), X-ray powder Diffraction (XRD), surface area (BET) and electrical conductivity measurements. XRD patterns showed the presence of the cassiterite structure. SnO2 particles, prepared through sol-gel method exhibit crystallite sizes in the range from 3.1 to 22.3 nm when the gel is heat treated at different temperatures up to 900?C. SnO2 nanocrystallites prepared by the precipitation method are comparatively larger in size. The higher specific surface area was obtained for the powder prepared using sol-gel method and the obtained average grain size (d) is relatively large compared with th...
The problems are discussed of using radionuclide X-ray fluorescence analysis (the most frequently used source is "2"4"1Am) and neutron activation analysis for monitoring the chemical quality of the working environment of a welder. Elements determinable by these methods are listed and the advantages of the methods stated with regard to speed, simplicity and appropriate accuracy of measurement together with commercial availability of the instruments. Welding as a source of harmful substances is assessed by determination of the amount of chromium in aerosols generated by welding austenitic chromium-nickel steels. The described methods allow to obtain a complex image of the chemical nature of welding aerosols and to understand the mechanism of their impact on the human organism. (J.C.).
CH Cygni is a symbiotic star consisting of an M giant and an accreting white dwarf, which is known to be a highly variable X-ray source with a complex, two-component, spectra. Here we report on two Suzaku observations of CH Cyg, taken in 2006 January and May, during which the system was seen to be in a soft X-ray bright, hard X-ray faint state. Based on the extraordinary strength of the 6.4 keV fluorescent Fe K-alpha line, we show that the hard X-rays observed with Suzaku are dominated by scattering.
A method for detecting electrons emitted as secondary particles by photon incidence to a specimen, as well as a method of using the photons emitted by electron incidence as detecting particles are explained. Pd-Si(100)2{times}1 system is adopted for a case study of using photo-electron spectroscopy where synchrotron emitted light in soft X-ray region is used as the incident light. Pd atoms are deposited little by little on clean Si surface to investigate the electron structure of the surface, and the interface electron structure after bonded formation of Pd(thin film)-Si(substrate) is estimated. Radiation soft X-ray spectroscopy is employed to observe the real state of the bonded interface of Pd(thin film)-Si(substrate) prepared by depositing Pd film in a short period of time. In the case of radiation soft X-ray spectroscopy with electron beam excitation, bonded system of thin film ...
A method is reported which permits selective suppression of absorption of radioactive strontium from ingested food material, permitting the calcium to be available to the body. Studies were carried...Full Text Available
Here we examine Fe speciation within Fe-encrusted biofilms formed during 2-month seafloor incubations of sulfide mineral assemblages at the Main Endeavor Segment of the Juan de Fuca Ridge. The biofilms were distributed heterogeneously across the surface of the incubated sulfide and composed primarily of particles with a twisted stalk morphology resembling those produced by some aerobic Fe-oxidizing microorganisms. Our objectives were to determine the form of biofilm-associated Fe, and identify the sulfide minerals associated with microbial growth. We used micro-focused synchrotron-radiation X-ray fluorescence mapping (mu XRF), X-rayabsorption spectroscopy (mu EXAFS), and X-ray diffraction (mu XRD) in conjunction with focused ion beam (FIB) sectioning, and highresolution transmission electron microscopy (HRTEM). The chemical and mineralogical composition of an Fe-encrusted biofilm was queried at ...
The authors propose a method for determining the risk of femoral neck fracture in osteoporotic patients that is not based on densitometric techniques. The method is based on a structural analysis performed by a computer on data taken from a single digital anteroposterior projection of the hip. From the image, the effective cross-sectional area and cross-sectional moment of inertia are computed from attenuation principles. Together with other geometric measurements, these data are used in an engineering analysis to compute the yield strength of the proximal femur, under stress applied through the acetabulum in a one-legged stance. An index of fracture risk based on the ratio of estimated yield strength to body weight is proposed. Ultimately it is expected that this work will allow the clinician to estimate hip fracture risk in osteoporotic patient using widely available existing technology, a goal which has eluded bone density-based ...
A method for the determination of stereotaxic coordinates in radiography, e.g. angiography, pneumoencephalography or digital vascular radiography, is described. A special localization frame containing radiopaque structures and scales defines a diagnostic coordinate system. This frame is fixed to the X-ray-table prior to the radiographic procedure and two projections are obtained at arbitrary angles to each other. The focus-film distances do not have to be fixed. The target coordinates are then determined either by a simple graphical procedure or with the use of a digitizing x-y-table, by a computer. With the computer method the films are placed on the digitizing table and the target and a few reference points are marked using a cursor. From the relative positions the computer calculates the coordinates. With the special head fixation system, coordinates of structures visualized in radiographic examinations can be ...
Dual energy X-ray absorptiometry (Hologic QDR-1000) was used to quantitatively analyze the diagnosis and prevention of osteoporosis. The peak bone mineral density (BMD) of the spine appeared in normal men in their twenties and in normal women in their thirties. There was acceleration of bone loss in the 50 to 60 year age bracket (premenopause and postmenopause) in normal women. On the contrary, the peak BMD of the femoral neck in normal men and women appeared in their twenties after which it decreased slightly with age. Comparison showed that the femoral neck BMD of normal women was lower than that of men throughout all ages. The fracture threshold, 0.756 g/cm[sup 2] for the spine, was obtained by scanning 73 females with spinal fractures, the mean BMDs for L2-L4 at the 90th percentile level were used as the fracture threshold. The fracture threshold of femoral neck fracture was the femoral proximal BMD of the 9th decile. Classification by the Public Welfare Silver ...
We studied the strain introduced in a Si(111) substrate due to MeV ion implantation using extremely asymmetric x-ray diffraction and measured the rocking curves of asymmetrical 113 diffraction for the Si substrates implanted with a 1.5 MeV Au"2"+ ion at fluence values of 1x10"1"3, 5x10"1"3, and 1x10"1"4/cm"2. The measured curves consisted of a bulk peak and accompanying subpeak with an interference fringe. The positional relationship of the bulk peak to the subpeak and the intensity variation of those peaks with respect to the wavelengths of the xrays indicated that crystal lattices near the surface were strained; the lattice spacing of surface normal (111) planes near the surface was larger than that of the bulk. Detailed strain profiles along the depth direction were successfully estimated using a curve-fitting method based on Darwin's dynamical diffraction theory. Comparing the shapes of resultant ...
In this work dosimetric analysis using thermoluminescence technique to study the beams characteristics of x-rays employed in dental radiology has been carried out. The obtained results with CaSO{sub 4}:Dy thermoluminescent dosimeters (TLD) were compared to the doses obtained with parallel-plates ionization chamber. Dosimetric evaluations were also done using radiographic films of large dimensions. The x-rays equipments analyzed were installed in the radiological services of Odontology Department of Sergipe Federal University (U.F.S.). Depending on the anatomical region to be examined the proper exposure time was select, for a fix voltage of 70 kV. The results with TLD and ionization chamber have been determined to female and male individuals. The intraoral regions analysed were the peri apical of the incisors, molar and pre-molar teeth and the occlusive region. These regions were simulated using acrylic plates absorbers installed on the film ...
Mesporous anatase-phase TiO(2) hollow spheres with high photocatalytic activity were prepared by hydrothermal treatment and self-transformation of amorphous TiO(2) solid spheres in an NH(4)F aqueous solution. The prepared samples were characterized by X-ray diffraction, scanning and transmission electron microscopy, X-ray photoelectron spectroscopy, N(2) adsorption-desorption isotherms and UV-vis absorption spectroscopy. The photocatalytic activity was evaluated by photocatalytic oxidation decomposition of acetone in air under UV irradiation. It is found that F(-) plays an essential role in the formation of TiO(2) hollow spheres. F(-) not only induces the hollowing of TiO(2) solid spheres, but also promotes the crystallization of anatase TiO(2) nanocrystals. A possible formation mechanism for the TiO(2) hollow spheres by localized Ostwald ripening or chemically induced self-transformation is proposed based on the ...
The absorption of carbonyl sulfide in aqueous methyldiethanolamine (MDEA) was studied over a range of temperatures and MDEA concentrations. MDEA is commonly used for selective absorption of hydrogen sulfide in the presence of carbon dioxide. However, sulfur in the form of COS may also be present and it is necessary that estimates of absorption rates of this compound be made. The objective of this study is to determine the physiochemical properties needed to predict COS absorption rates in aqueous MDEA. Free gas solubility and the diffusivity of COS in MDEA solutions were measured over the temperature range 15 to 40{sup 0}C for MDEA concentrations up to 30 weight per cent using the nitrous oxide analogy method. Solubilities were measured volumetrically in an equilibrium cell and diffusivities were measured using a laminar liquid jet absorber. The kinetics of the reaction between COS ...
A new microdensitometry method for quantitative assessment of bone mineral content using Fuji computed radiography (FCR) was developed and the results were compared with those obtained by the conventional film-screen method. Using both methods, X-ray pictures of the 2nd metacarpal bone were taken with a reference aluminum step wedge in nine normal subjects and nine parameters representing the width and density of bone marrow and cortex were calculated in middle of the bone shaft. Interobserver reproducibility assessed for three parameters was significantly higher in the FCR method than the conventional one. The value of {Sigma}GS computed by the FCR method, that is equivalent to the net bone density of the transverse section of the shaft, showed higher correlation with the one obtained by computed tomography in comparison with the conventional ...
A new microdensitometry method for quantitative assessment of bone mineral content using Fuji computed radiography (FCR) was developed and the results were compared with those obtained by the conventional film-screen method. Using both methods, X-ray pictures of the 2nd metacarpal bone were taken with a reference aluminum step wedge in nine normal subjects and nine parameters representing the width and density of bone marrow and cortex were calculated in middle of the bone shaft. Interobserver reproducibility assessed for three parameters was significantly higher in the FCR method than the conventional one. The value of #SIGMA#GS computed by the FCR method, that is equivalent to the net bone density of the transverse section of the shaft, showed higher correlation with the one obtained by computed tomography in comparison with the conventional ...
After having discussed the peculiarities of children in X-ray diagnosis the application of the effective as well as the mean equivalent doses as to the determination of the radiation exposure in children is represented. In using computerized tomograms to determine position and extent of an organ the exposure by repeated X-raying was calculated referring to the entrance dose. Entrance dose measurements for all types of X-ray examination in hospitals and ascertainments of the frequency of radiograms in 20 X-ray departments were used to determine per capita and collective doses, resp., in several age groups. Alltogether, the per capita dose of children in the GDR amounts to 30% of that of adults. Conclusions were drawn as to taking measures to further reduction of radiation exposure: (1) Technical measures, such as positioning of patients, shielding of organs, quality assurance; (2) elaboration of ...
Interest in optics for hard X-ray broad-band application is growing. In this paper, we compare the hard X-ray (20-100 keV) reflectivity obtained with an energy-dispersive reflectometer, of a standard commercial gold thin-film with that of a 600 bilayer W/Si X-ray supermirror. The reflectivity of the multilayer is found to agree extraordinarily well with theory (assuming an interface roughness of 4.5 Angstrom), while the agreement for the gold film is less, The overall performance of the supermirror is superior to that of gold, extending the band of reflection at least a factor of 2.8 beyond that of the gold, Various other design options are discussed, and we conclude that continued interest in the X-ray supermirror for broad-band hard X-ray applications is warranted.
A number of diagnostic X-ray units in Poland were subjected to analysis. The air kerma on X-ray tables was measured for the X-ray parameters used routinely during lumbo-sacral spine radiography of standard adult patient. Measurements of air kerma were performed using TLD made of lithium-fluoride. The doses received by patients in different X-ray departments can differ more than two orders of magnitude (from 0.42 mGy up to 72.11 mGy), for the same X-ray examination. The dose can be significantly reduced if fluorescent screens made from components of rare earth are used. (author). 10 refs, 1 fig., 2 tabs.
The authors present the results of their investigation of the effect of phosphorus compounds on the activity of tungsten-containing catalysts in the oxidation of ethane. They investigated tungsten-phosphorus catalysts with different phosphorus concentrations (calculated on the basis of P/sub 2/O/sub 5/). The catalysts were prepared by heat decomposition of the starting compounds at 750/sup 0/C for 4 h. As their starting compounds, they used two types of materials: heteropoly acids mixtures of monosubstituted ammonium phosphoric and tungstic acids. The specific surface area of the catalysts was determined using the nitrogen desorption method. The x-ray phase analysis was carried out using a DRON-1.5 diffractometer. The catalytic activity was determined using the impulse method in a reactor with a vibrofluidized catalyst layer.
Based on the X-ray crystallographic data of Tc-complexes for brain imaging agents, geometry optimizations in vacuo of TcO-BAT, TcO-MAMA, TcO-L, L-ECD, TcN-BAT and TcN-L, L-ECD complexes are performed with Hartree-Fock method and LANL 2 DZ basis set of G98W program. Then solvation free energy for each Tc-complex mentioned above in water is calculated by polarizable continuum method (PCM) including models of CPCM and IEFPCM. The results show that solvation free energy of Tc-complex is not only an indicator of lipophilicity but also one of the important factors that influence the brain uptake
Indium sulfide thin films consisting of porous network of nanoplatelets, have been deposited using chemical bath deposition (CBD) method onto the tin-doped indium oxide (ITO) coated glass substrate. Aqueous solutions of indium sulfate and thioacetamide have been used as indium and sulfur precursors. As a complexing agent, acetic acid was used. The chemically deposited indium sulfide thin films were examined for their structural, surface morphological and optical characterizations. The X-ray diffraction analysis revealed the formation of the cubic b-In2S3 onto the substrate. From scanning electron micrograph, it is observed that the surface of substrate is covered by nanoporous platelets type morphology. The optical studies showed a direct band gap of 2.84eV for indium sulfide platelets. Ph...
Ag nanoparticles were prepared in a water-phase system with a mixture of silver-ammonia complex, sodium borohydride, and lauric acid according to molar feed ratio of approximately 6:3:1. The mechanism of preparation and separation by chemical reduction-protection method was explored. The as-synthesized Ag nanoparticles were characterized by transmission electron microscopy (TEM), X-ray diffraction (XRD) and UV-vis spectroscopy, respectively. It was found that the size of high purity Ag particles was ranging from 30 to 50 nm with slight agglomeration. In addition, the as-synthesized wet Ag nanoparticles were dispersed stably in organic vehicle to formulate electrically conductive nanopaste. Upon direct-written and sintered, the array pattern of the nanopaste with the resolution of about 30 {mu}m was achieved with the electrical resistivity in the order of magnitude of 10{sup -5} {Omega} cm.
In connection with the different cyclical strengths of the two-phase (#alpha# + #beta#) titanium alloy in the case of the acicular and rounded formations of the #alpha#-phase, we have studied, employing the X-ray diffraction method, the phase composition of the alloy and the influence of heat treatment upon it. Using the method of electronic fractography, we examined the fractures in samples destroyed by the asymmetric twisting, in order to find out why the durability of the alloy is dependent upon the #alpha# - phase structure. It has been found that in the BT22 alloy, the decay the #beta#-phase may proceed in two ways; either with the formation of the martensite #alpha#'-phase of the acicular shape or with the separation of the non-martensite round-shaped #alpha#-phase. The character of the phase transformations #beta# - #alpha# or #beta#-#alpha#' is, to a considerable extent, the conseguence of the prehystory of the ...
Regularities of deformation-induced dissolution of a surface layer of iron oxides in matrixes of iron-based alloys with bcc and fcc lattices have been studied by the methods of M?ssbauer spectroscopy, transmission electron microscopy, and X-ray diffraction. A method of producing iron alloys strengthened by dispersed oxide nanoparticles and alloyed with elements possessing a high affinity to oxygen (titanium and yttrium) has been proposed, which implies a dynamic dissolution of a surface layer of iron oxides upon strong cold deformation and a precipitation of secondary yttrium and titanium nanooxides upon a subsequent high-temperature sintering of mechanically alloyed powders. There has been demonstrated a possibility of oxide strengthening of pure iron upon its interaction with air without...
One third of the microstructure of glassy carbon (GC) consists of closed pores. Density measurements indicate that the total pore volume depends only on the heat treatment temperature and not on the heat treatment time, a characteristic of coarsening. The kinetics of coarsening of these pores on heat treatment has been investigated by analyzing the changes in specific surface area of the pores as determined by the small angle X-ray scattering (SAXS) technique. A part of the surface area change is due to thermal expansion induced microcracking. Both the superposition method after correcting the thermal expansion induced surface area change and the curve fitting method give an activation energy of 64 +/- 10 kcal/mole. This value is compared with the activation energies of various rate processes in graphite. A model of coarsening of the pores based on a vacancy migration mechanism is proposed.
Silicon layered structures containing porous silicon modified with various thermal treatments and epitaxial layers deposited on porous layers were studied with a number of complementary X-ray diffraction methods using synchrotron source. The methods of characterization included recording of rocking curves for reflections with various asymmetry as well as projection, section and micro-Laue topography. It was found that oxidizing and sintering of porous silicon seriously modified the strains in the porous layer and in some cases even inverting the sense of strain with respect to that in initially formed porous layer. Consequently the deposited epitaxial layer usually was not laterally coherent with the substrate. Some of investigated layers were not stable in time and after few months period exhibited significant lost of coherence of porous skeleton. (author)
Recent research carried out in laboratories showed that Saddle field neutral fast atom beam source is a promising method for nitriding of stainless steel. In the present work, the effect of treatment time on the microstructural and mechanical properties of plasma-nitrided stainless steel sample was investigated by this new method. Plasma nitriding was carried out at 420 deg. C and at a pressure of 0.1 Pa for a time range of 1 to 12 h. SEM-EDX, microhardness tests, optical microscopy and X-ray diffraction (XRD) were used to evaluate the mechanical and structural properties of the nitrided layer. It was found that nitriding time has a pronounced effect on the structural and mechanical properties of low-temperature plasma-nitrided samples and produced a precipitation-free thin hard nitrided layer within a short processing time.
In principle four different methods (ultrasound, microwaves, {gamma}-radiation and x-rays) are available for the non-destructive testing of refractories. Three of these methods, i.e. ultrasound, microwaves and {gamma}-radiation, are in use by different producers of AZS materials to carry out the quality control of their products. This paper will compare the three methods on the basis of the physical properties, present the existing devices, and show the advantages as well as the limits of the different methods. {gamma}-radiography, the oldest method in use, has one main disadvantage, which is the requirement of protection against radioactive radiation. Furthermore, while cracks and cavities can be detected with this method, structural changes can not be monitored. Therefore, the ultrasonic method was developed that ...
GaAs1-xPx p-n junction structures were grown on the epi-ready n-type GaAs(100) substrate by solid source MBE system for different phosphor compositions. To obtain the lattice-match sample structure was applied graded growth procedure. The structural and optical properties of the sample structures with different P concentration were investigated by using X-ray diffraction (XRD), spectroscopic ellipsometry (SE). In addition, The range of lattice parameters in the graded epilayer and phosphorous composition were determined from the HRXRD rocking curve simulation. We analyse dielectric function spectra of disordered GaAs1-xPx junction structures measured using spectroscopic ellipsometry at room temperature in the 0.6-4.7 eV photon energy region. The critical energy points such as band gap energy and spin-orbit-split energy of these structures were determined using SE data. It is detected that E0, E1 ,E2 energies of the GaAs1-xPx p-n junction structures increase of ...
Copper(II) complex coordinated with cyclam-type macrocyclic tetramine, C-meso-1,5,8,12-tetramethyl-1,4,8,11-tetraazacyclotetradecane (2Cdmc) has been synthesized and characterized by single crystal X-ray crystallographic analysis and UV?Vis absorption spectra. Solved molecular structure of [Cu(2Cdmc)(H2O)]Cl2?2H2O (1) revealed that macrocyclic ligand 2Cdmc was in the most stable trans-III structure, but the C-methyl groups of 2Cdmc adopted energetically unfavorable axial configuration (C-axial). This complex 1 is the second example of complex of cyclam-type tetramine with only axially oriented C-methyl groups. This complex adopted five-coordinated square-pyramidal geometry with one water molecule occupying one of the two apical sites. Network of hydrogen bonds involving counter anions (Cl?...
Self-assembled monolayers (SAMs) on various metal, semiconductor or insulator substrates can be easily modified with specific functional groups of interest and have promising applications in surface wetting (hydrophobic/hydrophilic modification), tribology, corrosion protection, sensor electrodes modification, molecular and biomolecular recognition, protein adsorption, cell adhesion, and molecular- or organic-electronic device fabrications. In this paper, we highlight recent progress in the development of SAMs on solid substrates as well as their practical applications, with particular emphasis on the characterization of self-assembled aromatic thiol monolayers with different functional groups on Au(1 1 1) using synchrotron-based photoemission spectroscopy and near-edge X-rayabsorption fine structure measurements. The SAM-related molecular orientation, electronic structures, and chemical bonding are presented. Using copper(II) phthalocyanine ...
In this study, WO{sub 3} thin films were grown on glass substrates using an aqueous solution containing tungstate (NH{sub 4}){sub 2}WO{sub 4} as precursor. The substrate temperature incremented from 250 to 500 deg. C, by steps of 50 deg. C. The structural properties were investigated using XRD, atomic force microscopy and scanning electronic microscopy techniques. Microprobe analyses showed that a balanced stoichiometric composition was obtained for thin films prepared at T{sub s} = 350 and 400 deg. C. The X-ray diffraction analyses showed different structure crystallography in function of the substrate temperature. Moreover, films deposited at 400 deg. C were annealed in air for 2 h at 450 and 500 deg. C, respectively and the structural changes due to heat treatment were studied. Finally, the optical properties of these films were carried out using optical measurements of transmittance T({lambda}) and reflectance R({lambda}) spectra in 300-1800 nm domain. The ...
In this study, WO3 thin films were grown on glass substrates using an aqueous solution containing tungstate (NH4)2WO4 as precursor. The substrate temperature incremented from 250 to 500 deg. C, by steps of 50 deg. C. The structural properties were investigated using XRD, atomic force microscopy and scanning electronic microscopy techniques. Microprobe analyses showed that a balanced stoichiometric composition was obtained for thin films prepared at Ts = 350 and 400 deg. C. The X-ray diffraction analyses showed different structure crystallography in function of the substrate temperature. Moreover, films deposited at 400 deg. C were annealed in air for 2 h at 450 and 500 deg. C, respectively and the structural changes due to heat treatment were studied. Finally, the optical properties of these films were carried out using optical measurements of transmittance T(?) and reflectance R(?) spectra in 300-1800 nm domain. The refractive and absorption ...
Numerical simulations predict that a large number of baryons reside in intergalactic space at temperatures between 10^5-10^7 K. Highly-ionized metals, such as O VII and O VIII, are good tracers of this ``warm-hot intergalactic medium'', or WHIM. For collisionally-ionized gas, the ionization fraction of each ion peaks at some particular temperature (``peak temperatures''), so different ions can therefore trace the IGM at different temperatures. We performed a hydrodynamic simulation to study the metal distributions in the IGM. We then draw random lines-of-sight across the simulated region and synthesize resonance absorption line spectra in a similar way to simulating the Ly-alpha forest. By studying the distribution functions of H- and He-like O, Si and Fe in a collisionally-ionized IGM and comparing with semi-analytic results based on the Press-Schechter formalism, we find: (1) ions with higher peak temperatures (for instance, Fe XXVI) tend to concentrate around ...
Thin, lightweight, and flexible gas-diffusion electrodes (GDEs) based on freestanding entangled networks of single-walled carbon nanotubes (SWNTs) decorated with Ag nanoparticles (AgNPs) are tested as the air-breathing cathode in a zinc-air battery. The SWNT networks provide a highly porous surface for active oxygen absorption and diffusion. The high conductivity of SWNTs coupled with the catalytic activity of AgNPs for oxygen reduction leads to an improvement in the performance of the zinc-air cell. By modulating the pH value and the reaction time, different sizes of AgNPs are decorated uniformly on the SWNTs, as revealed by transmission electron microscopy and powder X-ray diffraction. AgNPs with sizes of 3-5 nm double the capacity and specific energy of a zinc-air battery as compared with bare SWNTs. The simplified, lightweight architecture shows significant advantages over conventional carbon-based GDEs in terms of weight, thickness and ...
The CaWO{sub 4}:Ln{sup 3+} SiO{sub 2} (Ln=Tb, Dy and Ho) nanoparticles were synthesized via a combustion process at 800 {sup o}C, using citric acid as chelating agent and fuel, ammonium nitrate as fuel, boric acid as flux material and silica as supports. The persistent phosphor nanoparticles were characterized by X-ray diffraction (XRD), reflectance UV-vis and fluorescence spectroscopy (PL) and transmission electron microscopy (TEM) techniques. XRD patterns indicated that crystalline calcium tungstate with scheelite structure was produced. The reflectance UV-vis spectra showed the broad absorption band of WO{sub 4}{sup 2-} groups and the PL spectra showed the WO{sub 4}{sup 2-} wide excitation band, broad emission band of WO{sub 4}{sup 2-} and characteristic emissions of Ln{sup 3+} ions. The average particle sizes were determined by TEM, which are about 50 nm.
The CaWO_4:Ln"3"+ SiO_2 (Ln=Tb, Dy and Ho) nanoparticles were synthesized via a combustion process at 800 "oC, using citric acid as chelating agent and fuel, ammonium nitrate as fuel, boric acid as flux material and silica as supports. The persistent phosphor nanoparticles were characterized by X-ray diffraction (XRD), reflectance UV-vis and fluorescence spectroscopy (PL) and transmission electron microscopy (TEM) techniques. XRD patterns indicated that crystalline calcium tungstate with scheelite structure was produced. The reflectance UV-vis spectra showed the broad absorption band of WO_4"2"- groups and the PL spectra showed the WO_4"2"- wide excitation band, broad emission band of WO_4"2"- and characteristic emissions of Ln"3"+ ions. The average particle sizes were determined by TEM, which are about 50 nm.
The mobility of metals in ground water is an important consideration for evaluating remedial options at the Asarco smelter site. Tacoma, Washington. One factor in assessing metal mobility is the degree of secondary mineralization in a slag-fill aquifer extending into the intertidal zone along the Puget Sound shoreline. Samples of aquifer material were collected for mineralogical analysis from borehole MW-206 at five-foot intervals within the slag fill from 5 to 25 feet below the ground surface, and in the underlying marine sand and gravel at 27 feet. Grab samples of slag fragments with visually apparent secondary minerals were also collected at five intermediate depths between 12 and 19 feet. Samples were analyzed by a variety of techniques including hydride generation/atomic absorption for arsenic concentration, scanning electron microscopy/electron microprobe for mineralogical texture and microanalysis, powder x-ray diffraction for mineral ...
A variety of platinum(II) complexes of methimazole (2-mercapto-1-methylimidazole; HImS=neutral form and ImS=thiolate form), coordinated in both thione and thiolate forms, have been isolated by reacting methimazole with [PtCl(terpy)]Cl (terpy=2,2prime:6prime,2Prime terpyridine), [PtCl2(bipy)] (bipy=bipyridine), [PtCl2(o-phen)] (o-phen=o-phenanthroline), [PtCl2(CH3CN)2] and [PtCl2(COD)] (COD=1,5-cyclooctadiene). These complexes were characterized by electronic absorption, IR and NMR (1H, 13C, 195Pt) spectroscopies. Molecular structure of [Pt(bipy)(HImS)2]Cl23H2O (3a3H2O) has been established by single crystal X-ray crystallography. Platinum thiolate complex, [Pt(ImS)2(HImS)2] (5), could be obtained by treatment of [Pt(HImS)4]Cl2 with sodium methoxide in methanol. The solution of 5 in organic...
Langmuir-Blodgett films have been made with 3-n-hexadecylpyrrole and 3-n-octadecylpyrrole monomers and copolymers with unsubstituted pyrrole made by chemical polymerization at the air-water interface on a subphase containing FeCl/sub 3/. Langmuir-Blodgett films consisting of mixtures of stearic acid and alkylsubstituted polythiophenes have also been made as bilayer films. The orientation of single and multilayer films on platinum substrates have been studied by Near Edge X-rayAbsorption Fine Structure Spectroscopy which also gives information about charge transfer interactions between the aromatic groups and the metallic substrates. The alkylsubstituted pyrroles form highly ordered two-dimensional structures. FeCl/sub 3/ initiated copolymerization with unsubstituted pyrrole leads to a more disordered system. In the case of polythiophene-stearic acid bilayers, the stearic acid layers are highly ordered. The poly(alkyl thiophene) layers ...
Red mud is a by-product of the alkaline extraction of aluminum from the bauxite and represents a renewed environmental problem due the significant annual throughput by the plants. In the present work, the pozzolanic properties of Brazilian red mud fired at 600, 700, 800 and 900 deg C were investigated by monitoring lime consumption using DTA analysis and Brazilian standard methodology NBR 5772 (1992). Products and kinetics of hydration were determined in cement pastes produced with 5 and 15% red mud using x-ray diffraction and DTA analysis. Compressive strength and capillary absorption tests were realized on mortars constituted by 5, 10 and 15% red mud in replacement of cement. When calcined at 600 deg C, the red mud develops good pozzolanic properties, and the compressive strength of mortars produced with this waste meet values in accordance with regulatory standard. These results shown than red mud can be used, in partial replacement of ...
Red mud is a by-product of the alkaline extraction of aluminum from the bauxite and represents a renewed environmental problem due the significant annual throughput by the plants. In the present work, the pozzolanic properties of Brazilian red mud fired at 600, 700, 800 and 900 deg C were investigated by monitoring lime consumption using DTA analysis and Brazilian standard methodology NBR 5772 (1992). Products and kinetics of hydration were determined in cement pastes produced with 5 and 15% red mud using x-ray diffraction and DTA analysis. Compressive strength and capillary absorption tests were realized on mortars constituted by 5, 10 and 15% red mud in replacement of cement. When calcined at 600 deg C, the red mud develops good pozzolanic properties, and the compressive strength of mortars produced with this waste meet values in accordance with regulatory standard. These results shown than red mud can be used, in partial replacement of ...
The fundamental optical properties of dysprosium (Dy) doped strontium sulfide bulk samples for various dopant concentrations from 0.1 to 1.0 at.% were investigated by X-ray diffraction (XRD), electron paramagnetic resonance spectroscopy (EPR), room temperature photoluminescence (PL), photoluminescence excitation (PLE) and diffuse reflectance spectroscopy (DRS). Investigations by electron paramagnetic resonance yielded the state of Dy in the sample as Dy3+. An additional ESR line due to F+ center was observed. The PL emission spectrum consisted of several intense lines and a number of weaker ones which were identified as transitions between energy levels of Dy3+. The optimum doping concentration for maximum intensity was found to be 0.25 at.%. Blue shift of the absorption edge energy and red shift of the PLE spectrum were observed with increasing doping concentration. The former is due to Burstein-Moss (BM) effect and the latter is attributed ...
We have investigated CeTSi{sub 3} and CeTGe{sub 3} (T = Rh and Ir) by measuring the magnetic susceptibility, specific heat, electrical resistivity, the resonant inverse photoemission (RIPES) and M{sub IV,V} x-rayabsorption spectra (XAS). The germanides showed a very weak Kondo effect, but the silicides exhibited a negatively large Weiss temperature (approx. = -130 K) and a lnT dependence of magnetic resistivity above 100 K, suggesting that they are a Kondo-lattice compound with a high Kondo temperature T{sub K} (approx. = 100 K). The Curie-Weiss law suggests that Ce atoms in these compounds remain close to 3+ down to about 150 K in spite of their high T{sub K}. In general, both RIPES and M{sub IV,V} XAS support their apparently stable valency. (author)
The paper presents the preparation, X-ray powder diffraction data as well as some magnetic and spectroscopic properties of a new uranium(III) complex bromide of the formula NH{sub 4}UBr{sub 4}.1.5CH{sub 3}CN.6H{sub 2}O. The compound crystallizes in the monoclinic system with a=11.877 A, b=6.385 A, c=6.815 A, {beta}=101.29deg and Z=2. In the 60-240 K range it follows the Curie-Weiss law with {theta}=-37.24 K and {mu}{sub eff}=3.20 B.M. The IR and UV-VIS absorption spectra were recorded in the 80-4000 cm{sup -1} and 4000-26000 cm{sup -1} spectral ranges respectively. Thermal decomposition at a non-static high vacuum enabled the conversion of the compound into pure and anhydrous UBr{sub 3}. (orig.).
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In computed radiography, image processing (tone scale modification and edge enhancement) is possible, and is advantageous portal ...
In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In computed radiography, image processing (tone scale modification and edge enhancement) is possible, and is advantageous portal ...
Eu 4f electronic structures of a temperature-induced valence transition system EuPd{sub 2}Si{sub 2} have been investigated by bulk-sensitive high-resolution photoemission spectroscopy at temperatures from 20 to 300 K. The bulk Eu{sup 2+} 4f component is definitely distinguished from two surface Eu{sup 2+} 4f components. The changes in the spectral intensity of the bulk Eu{sup 2+} and Eu{sup 3+} 4f configurations and in the energy separation between these states are observed in the temperature dependent photoemission spectra. These temperature dependences are related to the valence transition of EuPd{sub 2}Si{sub 2}. The Eu mean valence is evaluated to be 2.75{+-}0.03 at 20 K and 2.30{+-}0.05 at 300 K. These values are in good agreement with those evaluated from Moessbauer and Eu L{sub III}-edge X-rayabsorption measurements.
A tri-functional polyhedral oligomeric silsesquioxane (POSS) based silane precursor R_xR_yR_z(SiO_3_/_2)_n (x + y + z = n = 6, 8, 10, ...) bearing 3-(N-(3-triethoxysilylpropyl)ureido)propyl, isooctyl and perfluoropropyl groups was synthesized and investigated as corrosion protective coating for AA 2024 alloy. Infrared reflection-absorption (IR RA) combined with X-ray photoelectron spectroscopy and atomic force microscopy provided information about partial self-assembling of coatings having a fluorine enriched upper layer with a low surface energy (#gamma#"t"o"t = 12.37 mN/m). The structural changes that accompanied corrosion produced under chronocoulometrical conditions were assessed from ex-situ IR RA spectra. A new band at 1690-1700 cm"-"1 appeared above the corrosion potential, and was assigned to the formation of amidonium ions and consequent relaxation of urea-urea associations.
PurposeThe goal of this study was to clarify the dynamics of tumor oxygen (partial pressure of oxygen, pO2) in SCC VII murine tumors in mice after X-ray...Full Text Available
Microplanar beam radiation therapy has been proposed to treat brain tumors by using a series of rapid exposures to an array of parallel x-ray beams, each beam having uniform microscopic thickness and...Full Text Available
The disulfide-reduced form of bovine ribonuclease A (RNAse A), with the Cys thiols irreversibly blocked, was characterized by small-angle x-ray scattering (SAXS). To help resolve the conflicting...Full Text Available
Radionuclide X-ray fluorescence analysis was used for the determination of iron, calcium, potassium, copper, manganese and zinc in waste water from the production process of citric acid.
Radionuclide X-ray fluorescence analysis was used for the determination of iron, calcium, potassium, copper, manganese and zinc in waste water from the production process of citric acid. (author).
Exact anatomic knowledge about the location of the gonads and the application of corresponding measures of radiation protection are the preconditions for an efficient reduction of the danger of a possible genetic damage as a result of radiation exposition during X-ray examination of the hip joint of newborns. (VJ).
Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and...Full Text Available
An examination of the noise of polycrystalline silicon thin film transistors, in the context of flat panel x-ray imager development, is reported. The study was conducted in the spirit of exploring...Full Text Available
An analytic model of magnetic torques applied to an accreting neutron star is employed to evaluate the magnetic dipole moments of x-ray pulsars. A new type of close binary system containing a neutron star is suggested.
Differential phase-contrast X-ray imaging has been performed in a Talbot-Lau configuration, where a multiline X-ray source was used instead of a combination of a hard-X-ray multiple slit and a normal focus X-ray generator. When the multiple slit is used, a high aspect ratio structure is needed and slit width should be below 10 ?m for its function. The fabrication and use of such a multislit can be omitted using the presented configuration. The multiline X-ray source was developed by making grooves on a tungsten rotating anode, which was irradiated by an electron beam to generate X-rays. An array of 10?m line sources with a pitch of 30?m was formed and combined with a 4.5 ?m pitch phase grating and a 5.3 ?m pitch amplitude grating to generate differential phase contrast. With a total exposure time of 40 s, a differential phase image depicting cartilages was ...
Experimental, relative intensities for the components of L X-ray were collected from literature, and atomic-number dependency of L#beta#/L#alpha# has been found. (author).
K_#beta#/ K_#alpha# x-ray intensity ratio of chromium were measured in different chromium compounds. The results show the variation of the intensity ratio as a function of the chemical environment around the metal ion. (author)
picture will download the highest resolution version available. M51: X-Rays from the Whirlpool Credit: A. Wilson (UMD) et al., CXC, NASA Explanation: Fresh from yesterday's...
Previous studies have shown that iterative in-line x-ray phase retrieval algorithms may have higher precision than direct retrieval algorithms. This communication compares three iterative phase...Full Text Available
Certain applications are described of radionuclide X-ray fluorescence analysis in the ore dressing industry, in the manufacture of building materials, in metallurgy, pharmacy, in the chemical, photographic and paper industries, in space exploration, in archeology and for measuring the thicknesses of thin layers of coatings. (ES).
The fundamentals and the technical application methods of the imaging procedures are discussed in detail with regard to their application in medicine. The development of the X-ray contrast media has led to a better tolerance and a significant reduction of risks. Problems relating to radiation protection and radiation exposure are discussed critically. The general point gives an overview of the radiological examination methods and is meant to deepen the understanding of the special techniques and their rationally determined application. The following special part deals with diagnosing of organs in the region of the neck and the thorax. The general basis is the conventional radiological examination. The great increase in information achieved by means of the new imaging methods becomes clear if we look at the diagnostics of the soft tissue of the neck. Computerized tomography and NMR imaging open the view ...
The preparation by sputtering of artificial metallic superlattices is described, as are the results of x-ray structural determinations. Tunneling and resistivity measurements on these materials are reported.
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds were studied by electron and proton bombardments. L{sub {gamma}1} X-rays which involve transition of 4d electrons of the valence shell were found to be sensitive to the chemical environment. The L{sub {gamma}1}/L{sub {beta}1} X-ray intensity ratio increased with an increase of the 4d electron occupation of niobium or molybdenum in niobium or molybdenum compounds, showing that the chemical effects can be ascribed to the 4d electron behavior of the metallic atom in its compounds. (orig.).
Chemical effects of L X-ray intensity ratios in niobium and molybdenum compounds were studied by electron and proton bombardments. L_#gamma#_1 X-rays which involve transition of 4d electrons of the valence shell were found to be sensitive to the chemical environment. The L_#gamma#_1/L_#beta#_1 X-ray intensity ratio increased with an increase of the 4d electron occupation of niobium or molybdenum in niobium or molybdenum compounds, showing that the chemical effects can be ascribed to the 4d electron behavior of the metallic atom in its compounds. (orig.).
This case report evaluates X-ray findings in patients with miliary accumulation of mercury observed after parenteral application of metallic mercury in a suizide attempt. There are certain discrepancies between clinical symptoms and the X-ray findings. A clear demonstration of mercury in coronary blood vessels is possible by fluoroscopy.
These proceedings represent papers presented at the Astrophysics Conference in Maryland, USA. The topic of the Conference was the evolution of x-ray binaries and the papers encompass a wide range of subjects on x-ray astronomy. There were one hundred eighteen papers presented at the Conference and out of these three have been abstracted for the Energy Science and Technology database.
The physical foundations and methodology are described of radionuclide X-ray fluorescence analysis. The sources are listed of air, water and soil pollution, and the transfer of impurities into biological materials is described. A detailed description is presented of the sampling of air, soil and biological materials and their preparation for analysis. Greatest attention is devoted to radionuclide X-ray fluorescence analysis of the components of the environment. (ES).
The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.
Applications of X-ray fluorescence analysis in coal mining and geology are briefly described based on results published in Czechoslovakia as well as abroad over the past 3 years. Particular attention is paid to the rapid determination of the ash content of coal using portable radionuclide X-ray fluorescence analyzers that are being developed in Czechoslovakia. (author).
The achievement of inner-shell photoionization of Zn-like Pd by means of two exploding foils is described. This resulted in the soft X-ray transition 3d94s2-3d104p at 46 A. It is shown that the photoionization of inner shell electrons in highly stripped ions can lead to X-ray transitions which may be candidates for X-ray lasers under 50 A.
A brilliant Xray source is proposed for lithography instruments with use of a multi-mirror system. The inverse Compton scattering between the stored electron beam in the storage ring and the stored photon beam in the multi-mirror system, is applied for the X-ray generation. (author)
At the RIKEN-RAL Muon Facility, ?- to ? sticking K? X-rays were observed for the first time taking advantage of the pulsed beam structure. The precision of the present measurements was insufficient to distinguish between theoretical models, however the observed K?/K? X-ray intensity ratio tends to be smaller than most of these theoretical predictions.
Based on a literature study an actual summary of the risk-utility problems in X-ray diagnosis is outlined due to the Recommendations of the International Commission for Radiation Protection (ICRP publication 26/1977). Papers demonstrating quantitative assessment of the somatic and genetical risk in X-ray examination are preferably cited and evaluated. It is concluded that the somatic and genetical risk is low in diagnostic ratiology. However, it must not be neglected and has always to be compared to the utility of an examination as well as to other risks of the examination. (author).
In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).
Total potassium was assayed in 150 normal weight and obese females (cervical carcinoma-52, endometrial carcinoma-25 and breast cancer-73) by measurements of 40K spontaneous radiation in a low-background chamber. Control group included 30 healthy and 25 obese females. Computations of body cell and extracellular mass and fat were carried out on the basis of the said measurements. Extracellular fluid volume was measured in 38 patients by X-ray fluorescence method using sodium bromide. The results pointed to a body cell mass deficit matched by increased extracellular mass due to a higher fat level in patients with breast, endometrial and cervical carcinoma. The said correlation was particularly pronounced in obese patients. The beneficial effect of treatment was more often observed in patients with normal body weight. PMID:3739295
In this paper, the influence of plasma nitriding at temperature 720 deg. C for 20 h on the surface microstructure and interface microstructure of electroplated chromium coating was investigated. In these conditions, interdiffusion, mixing and reaction phenomena of elements originating from the substrate and coating material are more likely to occur, thus increasing the bonding strength between the coating and carbon steel substrate. The change of the structures from the substrate side to the coating surface, and the effect of the substrate steel on the interface structure were studied by cross-sectional transmission electron microscope observation (XTEM). The nitride layer formed on the surface was analyzed by X-ray diffraction method (XRD). After treatment at above conditions a 6-7 {mu}m thick nitride compound layer was formed in surface region and the same thick carbide compound layer was also formed in the interface region between ...
In this paper, the influence of plasma nitriding at temperature 720 deg. C for 20 h on the surface microstructure and interface microstructure of electroplated chromium coating was investigated. In these conditions, interdiffusion, mixing and reaction phenomena of elements originating from the substrate and coating material are more likely to occur, thus increasing the bonding strength between the coating and carbon steel substrate. The change of the structures from the substrate side to the coating surface, and the effect of the substrate steel on the interface structure were studied by cross-sectional transmission electron microscope observation (XTEM). The nitride layer formed on the surface was analyzed by X-ray diffraction method (XRD). After treatment at above conditions a 6-7 #mu#m thick nitride compound layer was formed in surface region and the same thick carbide compound layer was also formed in the interface region between ...
This paper presents results of studying the thermo-transferred thermoluminescence (TTTl) phenomenon in potassium-yttrium double fluoride doped with terbium (K_2YF_5_:Tb) at different impurity concentrations (0.8%, 0.95% and 0.99%). Previously to study the TTTl phenomenon, structural characterization and chemical composition of the materials were determined. The structural studies were conducted using a scanning electron microscope; meanwhile, chemical composition was analyzed using energy dispersive X-ray spectroscopy. Thermoluminescence kinetics was studied irradiating the samples with "1"3"7Cs gamma rays as well as with "9"0Sr/"9"0Y beta rays, analyzing the glow curves by the deconvolution method for obtaining the kinetic parameters. (Author)
A new in vivo method has been developed for the precise observation of RES activity. Both Escherichia coli endotoxin 100 #mu#g/100 g i.v. (LPS) and radiodetoxified endotoxin 100 #mu#g/100 g body weight i.v. (RD-LPS, TOLERIN) increased the granulopectic activity of RES. The RD-LPS was more effective. The preparation containing trace elements also increased the activity of RES. The treatment consisting of the use of both trace elements and RD-LPS proved to be the most effective. The activity of RES was inversely proportional to various doses of X-ray irradiation (7, 8, 9 Gy). Trace elements and RD-LPS even improved the immunity system of animals having deteriorated RES. (N.T.).
Antibacterial activity of Transition metals (Mn, Co) doped ZnO nanopowders prepared by a DC thermal plasma method against Escherichia coli and Staphylococcus aureus are investigated. The phase and morphology studies have been carried out by X-ray diffraction, scanning electron microscopy (SEM) and transmission electron microscopy (TEM) respectively. All the samples of the present investigation are found to have hexagonal wurtzite structure and crystallite sizes are found to vary from 25nm to 30nm. Our bacteriological study showed the enhanced antibacterial activity of transition metals doped ZnO nanoparticles than undoped ZnO indicating the great potential of ZnO nanoparticles in relevant clinical and biomedical applications.
In this article, we describe a method used to prepare an in situ sodium-activated, organomodified bentonite clay/styrene-butadiene rubber nanocomposite master batch via a latex blending technique. The clay master batch was used for compound formulation. Octadecyl amine was used as an organic intercalate. The clay was purchased from local suppliers and was very cheap. Sodium chloride was used for in situ activation of the clay. The wide-angle X-ray diffraction data indicated that the in situ sodium activation helped to increase the intergallery distance from 1.28 to 1.88 nm. A transmission electron micrograph indicated intercalation and partial exfoliation. The thermal properties were relatively better in the case of the sodium-activated, organomodified bentonite-clay-containing compound. A...
Research highlights: ? Reports a high protection system for the alloy in corrosive environment. ? Describes an interfacial process with self-healing properties. ? Reports the influence of substrate pre-treatment in the coating performance. - Abstract: In this paper the interface of poly(vinylidene fluoride) coatings prepared by the dip coating method and HF-treated AZ31 magnesium alloy was evaluated. The best performance of this system in corrosion tests compared to ground, as-received and acetic acid cleaned substrates is related to an acid-base interaction at the interface and to interfacial reactions which resulted in a self-healing process. The protectiveness of the samples was investigated using impedance and immersion tests while the coating morphology and interface stability were investigated by scanning electron microscopy, X-ray photoelectron spectroscopy and adhesion tests.
To study the effect of CuO on the electrochemical properties of MgNi alloy, the MgNi-xCuO (x = 3, 5 and 10 wt%) composites were prepared by ball-milling method. The X-ray diffraction (XRD) analysis showed that the structures of the composites were amorphous. The cycle stability of the composites was improved compared to pure MgNi alloy due to the enhancement of the anti-corrosion property in the alkaline electrolyte, and the composite with 5 wt% CuO ball-milled for 15 h exhibited the best performance. Electrochemical impedance spectroscopy (EIS) and potential-step measurements indicated that the electrochemical kinetics of the composites was improved.
Contradictory reports in the literature on the reliability of lymphography stimulated the authors to test the diagnostic accuracy, employing methods which are approximately analogous to practice, using carcinoma of the cervix as the model on which the study was carried out. Using 21 observers it was found that there was no correlation between their experience and on-target accuracy of the diagnosis. Good observers obtained an accuracy of 85% with good proportions between sensitivity in the recognition of detail, specificity and readiness to arrive at a decision on the basis of discriminatory ability. With the help of the concept of the ROC curves, the position taken up by the observers in respect of diagnostic decisions, and a complex manner of assessing the various characteristic factors determining diagnostic accuracy, are demonstrated. This form of test, which permits manipulation of different variants of diagnosis, is recommended, among other things, for ...
The influence of selenium dioxide (SeO2) on the microstructure and electrodeposition of manganese coatings obtained from a sulfate based neutral solution was investigated by material characterization methods and electrochemical techniques. The crystal structure and surface morphology of these coatings were studied by scanning electron microscopy (SEM) and powder X-ray diffraction spectroscopy (XRD), respectively. The SEM and XRD data showed that SeO2 could effectively accelerate phase transformation, and facilitate leveled and fine grain growth. The electrochemical results indicated that SeO2 could inhibit hydrogen evolution reaction and promote manganese deposition. The action of selenium dioxide in manganese deposition was found to be a reduction and adsorption mechanism. The process cou...
Phase and structural transformations in a multicomponent (5.05 mas.% Mo-4.95V-3.00Cr-3.05Al) metastable #beta#-titanium alloy on aging after plastic deformation are studied using methods of electron microscopy and X-ray diffraction analysis. The alloy is deformed by twinning in a #left brace#332#right brace# system, and even at initial stages the formation of a twin skeleton takes place in the structure, on further loading the deformation of the skeleton is by secondary twinning resulting in a high plasticity of the alloy. On annealing mechanical twins transform into #alpha#-phase - a ductile twin skeleton is replaced by a rigid skeleton of #alpha#-phase plates. The aging enhances the yield strength of the alloy but decreases sharply its plasticity
Three new phases with compositions, LaSr_2FeTiO_7, NdSr_2FeTiO_7 and GdSr_2FeTiO_7, were prepared by the traditional ceramic method. Lazy-Pulverix analysis of the X-ray diffraction data suggests that the phases crystallize in the RP-type (n = 2) structure in the space group, I4/mmm. The cell dimensions along the c-axis decrease with decrease in size of the rare earth ions. Electrical resistivity, as a function of temperature, shows that the materials are insulators and the resistivity decreases with decrease in the size of the rare earth ion, which is attributed to increase in the three-dimensional character. (author)
A detailed treatment is introduced to measure the dynamic stability of the relativistic electrons in a self-amplified spontaneous emission free-electron laser (FEL) system, which includes the numerical approach of the Kolmogorov entropy (entropy-like quantity), the general equations of motion for a charged particle and the method of monitoring the simulation accuracy. Numerical experiments reveal a new phenomenon that there exists the possibility of the transition from chaotic to non-chaotic phase-space trajectories of the strongly relativistic electrons due to the effect of their self-fields. The adiabatic magnetic field of a one-dimensional wiggler may have a slight influence on the electron transportation in the absence of the FEL fields, but substantially affects the dynamic stability of the electrons in the process of the FEL interaction. Moreover, the laser fields diminish the dynamic stability of the electrons as the FEL interaction grows exponentially.
Soluble starch?based biodegradable and microporous microspheres (SDM-Ms) were prepared by emulsion chemical cross-linking technique using trisodium trimetaphosphate (TSTP) as the cross-linker. The resultant amorphous SDM-Ms were excellently identified by scanning electron microscopy (SEM), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FT-IR). The internal rupture and surface-controlled erosion were the predominant degradation mechanisms for SDM-Ms. The obtained SDM-Ms were applied to adsorb coix seed oil (CSO) by immersing method. The adsorption capacity of CSO within SDM-Ms was determined, namely 0.5238?g/g, and the thermal stability was shown higher than that of the free CSO. A burst release appeared in the second hour, followed by controlled release. Diffusion, d...
Modeling calculations on the solubility of americium have indicated that basic americium carbonate, and not americium trihydroxide, is the solubility-controlling solid in the pH range from 6 to 10 under the influence of atmospheric CO{sub 2}. The solubility of crystalline {sup 243}AmOHCO{sup 3} has been investigated in batch experiments in near-neutral and basic solutions as a function of dissolution time in 0.1 M NaClO{sup 4} at room temperature under oxic conditions. After the solutions reached steady-state conditions, the influence of dissolved solids on the americium concentration in the supernatant solution was studied by utilizing several experimental methods to separate the solution phase from the solid. The solids were characterized by X-ray powder diffraction analysis.
Membranes in Palladium and its alloys, in particular Pd/Ag alloys, are selectively permeable to hydrogen and can therefore be used to purify hydrogen. It is intended to use them as material for electrodes in fuel cells. As the manufacturing process of a substrate Pd/Ag-layer consists of several stages and is still not completely understood, it would be advantageous to be able to characterise separately the layers of noble metals obtained by electro-plating . Attempts are being made in this work to vary the cristallographical structure of the deposited alloy by the choice of test parameters and by sintering when depositing the Pd/Ag. The layers produced are to be examined using an interference microscope and X-ray diffraction. Moreover, the diffusion behaviour of the hydrogen is to be examined with an electro-chemical pulse method specifically developed for this purpose. figs., tabs., 27 refs.
This paper reports the chemical compositions of chicken-blood stone Ji Xue Shi measured by Proton Induced X-ray Emission (PIXE). The experimental result show that for the red portion of chicken-blood stone, the concentration of Hg is as high as 20 wt%, and the concentration of S can be above 10 wt%. For the non-red portion the main chemical compositions are Al{sub 2}O{sub 3} and SiO{sub 2}. The obtained chemical compositions are close to those of kaolinite for Balin chicken-blood stone, and of pyrophyllite for Changhua chicken-blood stone, respectively. So far many Changhua chicken-blood stones and Balin chicken-blood stones were found in China, the PIXE method can be used to explore the provenance of available chicken-blood stones. (author)
Beta-SiAlON powders have been synthesized using natural clay containing kaolin and quartz by carbothermal reduction and nitridation (CRN), then beta-SiAlON bonded corundum multiphase materials have been sintered using the as prepared powders. The results indicated that both the holding time and sintering temperature are relatively significant in accordance with optimal analysis by orthogonal method. Reaction process can be briefly interpreted by means of X-ray Diffraction and Difference Temperature Analysis as well as phase diagram principle. Bending strength and bulk density were measured in SiAlON in situ bonded corundum materials with doped various sintering agents. Furthermore, the relevant mechanical properties and microstructure were discussed in detail.
The results of an investigation into tailed nuclei (TN) and features of dose dependence on frequency of the binuclear cells with TN in human lymphocyte cultures by cytogenetic block method upon X-ray radiation dose are presented. The frequencies of metaphases with dicentric and ring chromosomes are investigated concurrent with TN formed upon completion of first postradiation mitosis. Frequency of the appearance of binuclear cells with nuclei having outgrowth into the cytoplasmic space and arises after first mitosis in human lymphocyte culture is linear-square dependent on the X-irradiation at doses from 0.0 to 4.0 Gy. Positive correlation between frequency of cells with tailed nuclei and frequency of metaphases of first mitosis having dicentric and rings was established. Apparently, formation such TN is connected with dicentric and rings
Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)
A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.
The structure of nano-porous carbon, obtained by means of chlorination of carbide compounds with various crystal structure (SiC, TiC, Mo_2C) is studied through the method of small-angle diffraction. The angular dependences of the scattering intensity obtained are interpreted as the result of scattering from the nanoparticles of different size. The functions of the scattering particles distribution by the m(R_g) inertia radii are determined. It is shown that in spite of the source carbide, the highest fraction of the volume in the porous carbon constitute the particles with R_g #approx# 5 A. The nanoparticles in the samples obtained from SiC, wherein the average value of the R_g"a"v < 6 A, are most uniform by size. The nanoparticles in the porous carbon, obtained from Mo_2C, are on the average by two times larger
To study #beta# #reversible# #omega#-transformation in pseudo-#beta#-titanium alloy VT30, doped by hydrogen, methods of X-ray diffraction and thermodifferential analyses are used. It is established that in the process of heating of the hardened alloy from 0.004-0.1% H first formation and then dissolution of #omega# phase take place. An increase in hydrogen content to 0.1% decreases thermal effect of the processes and does not affect the temperature of #beta# #reversible# #omega#-transformation. Introduction of hydrogen in the concentration of 0.2% and higher suppresses completely #beta# #reversible# #omega# - transformation. A decrease in heating rate displaces #beta# #reversible# #omega#-transformation to lower temperatures.
Nd{sub 40}Fe{sub 30}Al{sub 10}Co{sub 15}B{sub 5} alloys were fabricated by high energy ball milling method under various conditions. Microstructure of the alloys was investigated by X-ray diffraction and electron microscopy techniques. Magnetic properties were characterized by hysteresis and thermomagnetic measurements. The high coercive fields up to 2.36 T have been observed on the samples consisting of Nd{sub 2}(Fe,Co,Al){sub 14}B, Nd{sub 6}(Fe,Co,Al){sub 14} and Nd crystallites imbedded in a residual amorphous matrix.
In order to quantify the biomass burning emissions, the main atmospheric pollution source of tropical and subtropical regions, we carried out the analysis of ashes that are also formed during these fires. To this end, we developed analytical methods to characterize the composition of savannah grass burning ashes by using X-ray fluorescence for mineral elements and microanalysis for C, H, O and N. Samples used in this work have been collected during laboratory combustion experiments, with chemically well-defined natural savannah grasses from Ivory Coasts and South Africa. The reproducibility and efficiency of different developed procedures have been studies. The analytical relative precision is generally better than 5%. This development has allowed to establish, for the first time, the global mass balance of ashes resulting from savannah grass burning. (authors). 16 refs., 3 figs., 8 tabs.
A comparison is made of the response of a count ratemeter and a pulse counter using the mathematical tool of the Z transform. Transform Z is used for the solution of the convolution integral interpreting the analog output of the count ratemeter used for recording characteristic radiation, excited in the moving beam. The comparison of count rates obtained by the count ratemeter during continuous analysis and the pulse counter during discontinuous measurement gave the transfer function of the count ratemeter in the actual range of count rate. Also discussed is the use of the transfer function for localizing concentration changes in the sample. The use of the described method is demonstrated on the determination of the tin content in tungsten using continuous radionuclide X-ray fluorescence analysis. (B.S.).
A microanalytical characterization of cast magnesium alloys of eutectic origin based on the Mg?Al?Ca ternary matrix system has been carried out in order to investigate the influence of alloying elements on their microstructure as well as microchemistry-processing-microstructural relations using structure-sensitive techniques of electron microscopy, mechanical spectroscopy (internal friction), X-ray diffractometry, and advanced microanalytical methods including electron probe compositional analysis. Following the data obtained here there is direct correlation of microstructure with creep properties of the new experimental magnesium alloys. The creep and heat-induced properties of the multicomponent magnesium alloys containing low range of inexpensive additions of titanium (0.07?0.2%) or str...
In this, the last of a series of three papers, we discuss a method of forming iron phosphate ceramics by a reduction process. We report the formation of iron oxide ceramics by reducing hematite with iron in a phosphoric acid solution. The reaction results in a rapid-setting ceramic (at room temperature) with a compressive strength of 3700 psi and a density of 1.7 g/cm{sup 3}. Although the exact mineral form of the binder is difficult to determine because it is mostly amorphous and hence is not amenable to X-ray diffraction analyses, this material is expected to consist of iron hydrophosphates. The reduction process is very useful in recycling several industrial wastes that are rich in hematite, including iron mine tailings, red mud (a caustic waste from the alumina industry), and machining swarfs. Formation of ceramics with red mud and swarfs is also discussed.
Bio-inspired palladium nanoparticles were synthesized by using banana peel extract (BPE), a non-toxic eco-friendly material. Boiled, crushed, acetone precipitated, air-dried peel powder was used to reduce palladium chloride. The palladium nanoparticles were characterized by using UV-Visible spectroscopy, scanning electron microscope-energy dispersive spectra (SEM-EDS) and X-ray diffraction (XRD) analysis. Dynamic light scattering (DLS) studies revealed the average size of nanoparticles to be 50nm. Fourier transform infra red spectroscopy (FTIR) implicated the role of carboxyl, amine and hydroxyl groups in the synthetic process. This paper thus describes a novel green method for the synthesis of palladium nanoparticles.
Hydrothermal method for preparing crystal borophosphate with zeolite structure is suggested. To increase absorption capacity and thermal stability of final product, aluminium hydroxide sol, ethylenediamine and ethyl acetate are added to the mixture of crystal boric and concentrated phosphoric acids. Thermal stability of the specimens prepared constitutes 880-950 deg, water absorption capacity is within the limits of 0.30-0.32 cmT/g. 1 table.
Certain problems of gamma-absorptionmethod of measuring the thickness of layers in multi-layer items are analyzed. Two examples of solving the above-mentioned problems have been considered. One of them deals with a two-layer item, its integral thickness being known or measured in advance, the second example is referred to a two-layer item with unknown integral value
Much research has been done to estimate the residual stress on a dissimilar metal weld. There are many methods to estimate the weld residual stress and FEM (Finite Element Method) is generally used due to the advantage of the parametric study. And the X-raymethod and a Hole Drilling technique for an experimental method are also usually used. The aim of this paper is to develop the appropriate FEM model to estimate the residual stresses of the dissimilar overlay weld pipe. For this, firstly, the specimen of the dissimilar overlay weld pipe was manufactured. The SA 508 Gr3 nozzle, the SA 182 safe end and SA376 pipe were welded by the Alloy 182. And the overlay weld by the Alloy 52M was performed. The residual stress of this specimen was measured by using the Neutron Diffraction device in the HANARO (High-flux Advanced Neutron Application ReactOr) research reactor, KAERI (Korea Atomic ...
There is growing interest in the generation and characterization of femtosecond and subfemtosecond pulses from linac-based free-electron lasers (FELs). In this report, following the method of Ricci and Smith (Phys. Rev. ST Accel. Beams 3, 032801 (2000)), we investigate the measurement of the longitudinal bunch profile of an ultrashort electron bunch produced by these FELs. We show that this method can be applied in a straightforward manner at x-ray FEL facilities such as the Linac Coherent Light Source by slightly adjusting the second bunch compressor followed by running the bunch on an rf zero-crossing phase of the final linac. We find that the linac wakefield strongly perturbs the measurement, and through analysis show that it can be compensated in a simple way. We demonstrate the effectiveness of this method and wakefield compensation through numerical simulations, including effects of coherent ...
A miniature x-ray source utilizing a hot filament cathode. The source has a millimeter scale size and is capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature source consists of a compact vacuum tube assembly containing the hot filament cathode, an anode, a high voltage feedthru for delivering high voltage to the cathode, a getter for maintaining high vacuum, a connector for initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is fabricated from highly x-ray transparent materials, such as sapphire, diamond, or boron nitride.
An x-ray diffraction technique for determining thin-film thickness is presented which should prove to be a valuable alternative to the array of spectroscopies (Rutherford backscattering spectrometry, Auger electron spectroscopy, etc.) currently favored for these measurements. Some of the virtues of this x-ray diffraction approach are its nondestructive nature, fast data acquisition rate (enabling in situ observations), thickness resolution better than 5 nm, and conventional equipment requirements. Results are shown for Pd/sub 2/Si thin films grown during isothermal annealing of Pd coatings (100 nm) on Si at 200 /sup 0/C for various amounts of time. A comparison of these x-ray measurements with Rutherford backscattering spectrometry data taken from the same specimens is used to demonstrate the validity of the x-ray technique.
The interaction of intense, sub-picosecond laser pulses with solid targets produces intense picosecond x-ray pulses. With focused laser pulses of several 10 {sup 18} W/cm{sup 2}, He-like and H-like line radiation from targets such as aluminum and silicon has been produced. The energy conversion efficiency from the laser pulse energy to the 1--2 keV line x-rays is nearly one percent. The duration of the line x-ray radiation is of the order of ten picoseconds, although this may be an upper estimate because of the temporal resolution of the x-ray streak camera. The spatial extent of the x-ray source region is only slightly larger than the laser focal spot, or about 10 {mu}m in diameter. With these characteristics, such x-ray sources emit an intensity of nearly 10{sup 14} W/cm{sup 2}. Experiments and modeling which led to the above conclusions will be discussed.
Oxide superconducting thin films were irradiated with X-rays and ultra-violet (UV) light, and induced radiation effects on electrical and chemical properties were examined by transport measurement, X-ray diffraction analysis (XRD), diamagnetization measurement and X-ray photoemission spectroscopy (XPS). After irradiation for ErBa_2Cu_3O_x films with X-rays emitted from a Rh tube for 100 hours, superconductivity was remarkably damaged, destroying the zero-resistance state. The UV-light irradiation for Bi_2Sr_2CaCu_2O_x films was performed in He gas of about 500 Pa with a low pressure mercury lamp. The superconductivity was gradually degraded with the UV irradiation time up to 70 minutes. In both cases, adequate oxygen-annealing treatments restored superconductivity. The X-ray photoemission spectra showed that the mean Cu valence of the films was decreased approximately from +2 to +1 ...
A portable X-ray image system is described comprising: (a) a base assembly including panels and hinges joining the panels together along edges, and compression stops for biasing the hinges to compensate for the weight of payload when mounted on the base assembly, the compression stops being located for interaction with the hinges for biasing the panels to exhibit upward bowing when laid upon a flat surface prior to loading, and to provide resiliency for facilitating the base assembly assuming a substantially flat configuration when a predetermined payload is placed upon the base assembly; (b) an X-ray member; (c) apparatus for detachably mounting a table member to the base assembly to hold the table member at a location above the base; (d) an X-ray source; (e) means for sensing X-rays to form an image; (f) means for mounting the X-ray source and the X-ray ...
The peak flux relationship between hard X-rays and microwaves from solar flares is studied using about 400 events simultaneously recorded with the hard X-ray burst spectrometer on the SMM satellite and the Nobeyama 17 GHz radiometer. The data indicate that the hard X-ray and microwave peak fluxes correlate best for X-ray energies of less than about 80 keV for impulsive flares and greater than about 360 keV for extended flares. By postulating that electrons responsible for microwave emission at 17 GHz are those emitting hard X-rays at these photon energies, it is concluded that: (1) in impulsive flares, microwaves at about 20 GHz are emitted mainly by electrons of less than about 200 keV from a layer through which the electrons stream down into the thick-target hard X-ray source; and (2) in extended flares, microwaves are emitted mainly by MeV electrons trapped ...
Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two detectors, respectively ...
We report the detection of X-ray pulsations with a period of ?315.87 ms from the 2009 XMM-Newton observation for the radio-quiet ?-ray pulsar, LAT PSR J0007+7303, centered in the supernova remnant CTA 1. The detected pulsed period is consistent with the ?-ray periodicity at the same epoch found with the Fermi Gamma-ray Space Telescope. The broader sinusoidal structure in the folded light curve of the X-ray emission is dissimilar to that of the ?-ray emission, and the phase of the peak is about 0.5 shifting from the peak in the ?-ray bands, indicating that the main component of the X-rays originates from different sites of the pulsar. We conclude that the main component of the X-ray pulsation is contributed by the thermal emission from the neutron star. Although with a significantly different characteristic age, PSR J0007+7303 is similar to Geminga in emission properties of X-rays ...
The motivation of this work is to develop high reflectance normal-incidence multilayer mirrors in the 8-12 nm wavelength region for applications in astronomy and extreme ultraviolet lithography. To achieve this goal, Mo/Sr and Mo/Y multilayers were studied. These multilayers were deposited with a UHV magnetron sputtering system and their reflectances were measured with synchrotron radiation. High normal-incidence reflectances of 23% at 8.8 nm, 40.8% at 9.4 nm, and 48.3% at 10.5 nm were achieved. However, the reflectance of Mo/Sr multilayers decreased rapidly after exposure to air. Attempts to use thin layers of carbon to passivate the surface of Mo/Sr multilayers were unsuccessful. Experimental results on the refractive index {tilde n} = 1-{delta} + i{beta} of yttrium and molybdenum in the 50-1300 eV energy region are reported in this work. This is the first time ever that values on the refractive index of yttrium are measured in this energy range. The absorption ...
We demonstrate that fitted values of stellar radius obtained by fitting theoretical light curves to observations of millisecond period X-ray pulsars can significantly depend on the method used to calculate the light curves. The worst-case errors in the fitted radius are evaluated by restricting ourselves to the case of light emitted and received in the equatorial plane of a rapidly-rotating neutron star. First, using an approximate flux which is adapted to the one-dimensional nature of such an emission region, we show how pulse shapes can be constructed using an exact spacetime metric and fully accounting for time-delay effects. We compare this to a method which approximates the exterior spacetime of the star by the Schwarzschild metric, inserts special relativistic effects by hand, and neglects time-delay effects. By comparing these methods, we show that there are significant differences in these ...
The authors attemps to confirm a modification of the phase-absprotion method applicable to the study of the decay rate of energy stored in the upper level in the active medium of a CO/sub 2/-laser. The essence of the method is described. Relationships are determined which allow one to obtain the unknown parameters of the experimentally measured phase shift. The work exeprimentally shows the possibility of studying vibratioanl relaxation in the active medium of a CO/sub 2/-laser by the phase-absorptionmethod using both ordinary and isotope-substitued molecules.
A simple and rapid method is described for the determination of major and trace elements in rock and sediment samples by wavelength dispersive XRF. Sample measured were made from cellulose powder pressed into 4 cm diameter aluminium ring 0.4 t cm/sup -2/, and then 1 g of powdered sample (0.08 g cm/sup -2/) was placed on the disk and repressed at 1.6 t cm/sup -2/. X-ray measurements were performed for total XRF intensity (I/sub p/) at the characteristic line of each element and background intensity (I/sub b/) in vicinity of the line. The correction of matrix effect was achieved by X-ray intensity ratio of peak to background for each element. Eight standard rock samples from Geological Survey of Japan were used as standard materials, and linear calibration curves were obtained by the plot of I/sub p/ - I/sub b/ vs. concentration for Ca, Na and Pb and by the plot of I/sub p//I/sub b/ ratio vs. concentration for Si, Fe, Ti, K, ...
A simple and rapid method is described for the determination of major and trace elements in rock and sediment samples by wavelength dispersive XRF. Sample measured were made from cellulose powder pressed into 4 cm diameter aluminium ring 0.4 t cm"-"2, and then 1 g of powdered sample (0.08 g cm"-"2) was placed on the disk and repressed at 1.6 t cm"-"2. X-ray measurements were performed for total XRF intensity (I_p) at the characteristic line of each element and background intensity (I_b) in vicinity of the line. The correction of matrix effect was achieved by X-ray intensity ratio of peak to background for each element. Eight standard rock samples from Geological Survey of Japan were used as standard materials, and linear calibration curves were obtained by the plot of I_p - I_b vs. concentration for Ca, Na and Pb and by the plot of I_p/I_b ratio vs. concentration for Si, Fe, Ti, K, P, Cl, Cr, Mn, Ni, Cu, Zn, Pb, Sr and Ba, ...
A number of procedures in diagnostic radiology and cardiology make use of long exposures to x-rays from fluoroscopy units. Although numerous studies have been performed to measure or calculate skin dose from these procedures, there have only been a handful of studies to determine the dose to the other organs. This thesis was focused on devising a method to calculate the absorbed dose to underlying tissues and organs. The work was performed in several stages. First, a commercial convolution/superposition-based treatment planning system used in radiation oncology was modified and complemented to make it usable with the low energies of x-rays used in diagnostic radiology. This required generation of energy deposition kernels in the kilovoltage energy range. The kernels were generated using the EGS4 Monte Carlo system of codes and added to the treatment planning system. The treatment planning system was then evaluated for its ...
The design of the first structural wall (FSW) in an inertial confinement fusion (ICF) reactor requires some knowledge of the expected wall loading produced by x-ray and neutron deposition; specifically in the High Yield Lithium Injection Fusion Energy (HYLIFE) reactor, wall loading results from two sources -- gas shock and liquid impact. Gas shock is derived from x-ray deposition in the thin layers of exposed blanket material, producing ionized vapor, which will generate gas shock on the FSW. Liquid impact, on the other hand, results from the acceleration of liquid blanket material by two possible forces -- the drag from vapor expansion through the blanket material and the neutron-induced isochoric disassembly process. Both impacts, however, are coupled by the interaction of hot gas expanding through the liquid blanket. This paper discusses scaling methods for estimating pressure and impulse on the HYLIFE FSW from these ...
Microstructure and electrical properties of iron oxide Fe_2O_3 thin films prepared by spray pyrolysis method have been experimentally characterized. The effect of substrate temperature as well as deposition time on the structural features (crystallite size and microstrain) and electric resistivity of these films has been investigated. X-ray diffraction (XRD) and scanning electron microscope (SEM) characterized the structure study. The results of X-ray diffraction showed that with increasing substrate temperature bias the film structure changed from amorphous to crystalline at the same deposition time. At a substrate temperature of 350 deg. C and low deposition time, #alpha#-Fe_2O_3 appears almost in amorphous form. With rising the substrate temperature and deposition time, the crystallinity was improved. At T_s_u_b>350 deg. C, a well-crystallized rhombohedral phase of #alpha#-Fe_2O_3 was obtained. Single order Voigt ...
The x-ray diffraction technique described previously for measurement of growth kinetics of Pd/sub 2/Si layers from their solid state reaction couples has been extended by the use of a one-dimensional position-sensitive detector (PSD). Additionally, the method has been extended to include measurement of the Pd layer. A detailed description of the experimental arrangement and analytical procedures is presented. The kinetics of epitaxial Pd/sub 2/Si film growth were measured in situ over a range of 170--230 /sup 0/C. The PSD results, using data obtained from both the Pd/sub 2/Si and Pd layers, were able to confirm parabolic growth behavior for the Pd/sub 2/Si film. The rate constants followed Arrhenius behavior and yielded an activation energy of E = 1.32 +- 0.07 eV with a prefactor k/sub 0/ = 0.49 cm/sup 2//s for the Pd/sub 2/Si layer analysis and E = 1.34 +- 0.17 eV with a prefactor of 0.72 cm/sup 2//s for the Pd layer analysis. The PSD ...
A novel phantom has been developed to measure the modulation transfer function (MTF) in 3D for x-ray computed tomography. The phantom consists of three tungsten wires, positioned nearly orthogonal to each other. Simultaneous measurements of the MTF are taken at various locations along the three orthogonal reconstructed planes. Our computed mammotomography (CmT) system uses a Varian Paxscan 2520 digital x-ray detector which can be positioned anywhere in ~2pi steradian band and can have arbitrary trajectories. With a half-cone beam geometry and with the phantom positioned near the center of rotation, projection images are acquired over 360 degrees. Various 3D orbits are evaluated including vertical axis of rotation and saddle. Reconstructions were performed using an iterative ordered-subsets transmission algorithm on rebinned projection images, using various numbers of iterations. Rotation of reconstructed slices isolated each wire into its own ...
Metal nanoparticles have many potential technological applications. Biological routes to the synthesis of these particles have been proposed including production by vascular plants, known as phytoextraction. While many studies have looked at metal uptake by plants, particularly with regard to phytoremediation and hyperaccumulation, few have distinguished between metal deposition and metal salt accumulation. This work describes the uptake of AgNO{sub 3}, Na{sub 3}Ag(S{sub 2}O{sub 3}){sub 2}, and Ag(NH{sub 3}){sub 2}NO{sub 3} solutions by hydroponically grown Brassica juncea and the quantitative measurement of the conversion of these salts to silver metal nanoparticles. Using X-rayabsorption near edge spectroscopy (XANES) to determine the metal speciation within the plants, combined with atomic absorption spectroscopy (AAS) for total Ag, the quantity of reduction of Ag{sup I} to Ag{sup 0} is reported. Transmission electron ...
Silver iron oxide nanoparticles of fairly small size (average diameter approximately 1 nm) with narrow size distribution have been synthesized by the interaction of colloidal beta- Fe2O3 and silver nanoparticles. The surface morphology and size of these particles have been analyzed by using atomic force microscopy (AFM), field emission scanning electron microscopy (FESEM) and transmission electron microscopy (TEM). Their structural analysis has been carried out by employing x-ray diffraction (XRD), selected-area electron diffraction (SAED), optical and infrared (IR) spectroscopic techniques. The ageing of these particles exhibits the formation of self-assembly, possibly involving weak supramolecular interactions between Ag(I)O4 and Fe(III)O4 species. These particles display the onset of absorption in the near-infrared region and have higher absorption coefficient in the visible range compared to that of its precursors. ...
Absorption with aqueous amine solvents is at present the most viable technology for CO{sub 2} capture. While this is a proven technology, efforts are ongoing to improve it in order to make it a more attractive technology for large scale use to reduce CO{sub 2} emissions. Finding solvents with better properties is one approach to improving the technology. In this thesis methods in computational chemistry are used to improve the understanding of the chemistry of CO{sub 2} absorption in amine-water systems. The work is also intended to provide models that can be used to predict the performance of new solvents. Such predictive models are intended to facilitate the screening for new solvents
The subband structure and optical properties of a cylindrical quantum well wire under intense non-resonant laser field are investigated by taking into account the correct dressing effect for the confinement potential. The energy levels and wave functions are calculated within the effective mass- approximation using a finite element method. It is found that the absorption coefficient and the saturation intensity are strongly affected by the laser amplitude and frequency as well as by the incident light polarization. As a key result, a large anisotropy in the linear and nonlinear optical absorptions for very intense laser field is predicted. These effects can be useful for the design of polarization sensitive devices.
In this study nanocrystalline powders of yttria-stabilized zirconia (ZrO_2-8Y_2O_3) have been synthesized through 'polymerized complex method'. Zirconium chloride, yttrium nitrate, citric acid and ethylene glycol were polymerized at 80 "oC to produce a gel-like mass in which metallic ions were uniformly distributed. During the thermal treatment of dried gel, nanocrystalline powder was formed at 450 "oC and 650 "oC for 2 h. Thermal reactions and crystalline phase formation of the dried gel were investigated through thermal analysis and X-ray diffraction analysis, respectively. The results of thermal analysis and XRD showed the formation of nanocrystalline powder at less than 600 "oC. Chemical bonding of the dried gel was investigated by Fourier transform infrared spectroscopy analysis. Morphology of powder calcined at 650 "oC was analyzed by scanning electron microscope. Yttria-stabilized zirconia powders with the mean crystallite size of 6 nm ...
Molybdenum oxide nanostructures were synthesized utilizing the solution combustion method where the ammonium molybdate powder and an organic additive were used as precursors. Different organic additives including ethylene diamine tetra-acetic acid (EDTA), polyethylene glycol 200 (PEG 200), sorbitol and urea were used as surfactants in order to investigate the effect of additive structure on morphology and particle size of products. Also various reaction parameters such as the additive/Mo molar ratio, concentration of metal ion in solution, pH of the reaction, and temperature of the synthesis media were changed to study effects on product morphology and size. Outcomes were characterized by Scanning Electron Microscopy (SEM), X-ray diffraction, and Transmission Electron Microscopy (TEM) techniques. Results show a variety of MoO_3 nanoparticles and nanorods produced within the size range of 10-80 nm. Furthermore, microrods and microsheets were ...
Both x-ray and optical cone-beam CT (CBCT) scanners are limited by scattered photons that contaminate the primary images. Transparent radiochromic gels and plastics are anticipated to produce less scattering than polymerization gels and hence result in reconstructed dose distributions with greater contrast and dynamic range. Four methods of scatter measurement were investigated to quantify scatter fractions using an in-house optical CBCT scanner. The methods consisted of generating either 'coin' shadows or primary beamlets in transmission images. The four methods generated similar results of 10% scatter fractions in gel transmission images for this particular scanner configuration with both leuco crystal violet and carbon black micelle gels. The scatter contributions were distributed as 5% from micelle gel, 2% from Teflon wall, 2% from refractive index matching liquid and 1% other ...
The layer-by-layer (LBL) self-assembly has been extensively used as a simple and effective method for the preparation of polyelectrolyte multilayer films. In this work, we utilized this unique method to prepare polyimide precursor/layered double hydroxide (LDH) ultrathin films. Well-crystallized Co-Al-CO_3 LDH and subsequent anion exchanged Co-Al-NO_3 LDH were prepared and characterized by scanning electron microscopy and X-ray diffraction (XRD). By vigorous shaking of the as-prepared Co-Al-NO_3 LDH, positively charged and exfoliated LDH nanosheets were obtained. Atomic force microscopy and XRD investigations indicated the delamination of LDH nanosheets. The precursor of polyimide, poly(amic acid) tertiary amine salt (PAS) was prepared by the polycondensation of dianhydride and diamine, and subsequent amine salt formation. By using the LBL method, heterogeneous ultrathin films of PAS and LDH were ...
The passive films formed on iron metal, alloys or stainless steel are extremely thin oxides or hydroxides and possess the properties of high chemical stability in the environment. These films show characteristics interested both electrical as well as electrochemical point of view due to the thin thickness of the films. Auger Electron Spectroscopy, X-ray Photoelectron spectroscopy and so on which are the conventional electrochemical measurement methods or the surface analysis methods are used for the analysis and evaluation of these films, however, at present, the application of research technique focusing the superconductor characteristics of the films are tried. Although, the potential modulation reflection spectroscopy method has merits like possibility of in-situ measurement, high precision, possibility of stable analysis even for extremely thin film and so forth, it has also demerits like difficulty ...
A highly reliable screening method was developed for the determination of lead in tin plated layers and tin-bismuth plated layers. The contents of lead in the layers of the various samples were determined by inductively coupled plasma optical emission spectrometry. The calibration curve for lead in the tin and tin-bismuth plated layers by using WD-XRF exhibited linear correlation from 130 #mu#g/g to 2070 #mu#g/g. Calibration curve of lead normalized with Pb-L#alpha#/Sn-K#alpha# intensity was more linear, and this method was possible to evaluate very small sample. The calibration curve for lead in the tin plated layers by using ED-XRF was good linearly, but it for lead in the tin-bismuth plated layers was affected by Pb-L#alpha# spectrum and Bi-L#alpha# spectrum overlap each other. It was effective for decreasing affect of Bi-L#alpha# spectrum by using curve fitting method. (author)
A laboratory differential simulation method is used for the design of carbonization columns at coal-tar processing in which phenols are regenerated from phenolate solution by carbon dioxide absorption. The design method is based on integration of local absorption rates of carbon dioxide along the column. The local absorption rates into industrial phenolate mixture are measured in a laboratory model contactor for various compositions of the gas and liquid phases under the conditions that ensure the absorption rates in the laboratory absorber simulate the local rates in the industrial column. On the bases of the calculations, two-step carbonization columns were designed for 30000 t/year of the phenolate solution treatment by carbon dioxide. The absorption proceeds at higher pressure of 500 kPa and temperatures from 50 to 65 C, pure carbon ...