WorldWideScience
1

Biosorption for the separation of radionuclides from drainage and process waters of the uranium mining industry  

Energy Technology Data Exchange (ETDEWEB)

Biosorption means the storage of substances at the cell envelope. Different microbial biomasses were tested for the separation of radionuclides from mining waters. Results of a pilot plant demonstrate the ability of these techniques for water cleaning processes. An effluent concentration of lower than 1 mg/l (in most cases 0.1 mg/1) could be realized in a pilot plant by using pure cells of a methylotrophic strain of bacteria as well as using of a fungal mycelia.

1995-12-31

2

Analytical method for determination of the decontamination factor of an evaporation plant for radioactive waste water  

International Nuclear Information System (INIS)

Two inactive tracer techniques for determination of the decontamination factor (DF) of evaporation plants for radioactive waste water are described. One method was used for determination of the DF of an one stage pilot plant. The elements Mg, Cd and Co were employed as tracers. The analyses were performed by atomic absorption spectroscopy. The measurements being fast and simple are especially advantageous with test series in pilot plants. In the second method activation analysis was used for measurement of the tracer to determine the DF of a two stage evaporation plant. Europium is added to the stock solution in a concentration of 70 ppm only. With this method a DF of up to 3 . 10"8 can still be determined. (Auth.).

4

Telephone exchange Feutersoey - first pilot plant of the PTT with solar collectors  

Energy Technology Data Exchange (ETDEWEB)

In the course of this year six local exchange offices with alternative heating and hot water plants were started up in Switzerland. They are all of the same building type, designed for not more than 1000 telephone subscribers and for the same architectural conditions. However, the buildings are situated in different areas of the country and are thus subject to different environmental conditions. Solar collectors supplemented by electricity boilers are fitted to two of these objects. Heat pumps are operated in two other exchange offices while the last two are equipped with electric heating devices. For purposes of comparison two new test plants of the same size with oil heating devices are set up.

1981-01-01

5

Guidebook on design, construction and operation of pilot plants for uranium ore processing  

International Nuclear Information System (INIS)

The design, construction and operation of a pilot plant are often important stages in the development of a project for the production of uranium concentrates. Since building and operating a pilot plant is very costly and may not always be required, it is important that such a plant be built only after several prerequisites have been met. The main purpose of this guidebook is to discuss the objectives of a pilot plant and its proper role in the overall project. Given the wide range of conditions under which a pilot plant may be designed and operated, it is not possible to provide specific details. Instead, this book discusses the rationale for a pilot plant and provides guidelines with suggested solutions for a variety of problems that may be encountered. This ...

6

RCRA closure of the Building 3001 Storage Canal  

Energy Technology Data Exchange (ETDEWEB)

The 3001 Storage Canal is located under portions of Buildings 3001 and 3019 at Oak Ridge National Laboratory (ORNL) and has a capacity of approximately 62,000 gallons of water. The term canal has historically been used to identify this structure, however, the canal is an in-ground reinforced concrete structure satisfying the regulatory definition of a tank. From 1943 through 1963, the canal in Building 3001 was designed to be an integral part of the system for handling irradiated fuel from the Oak Ridge Graphite Reactor. Because one of the main initial purposes of the reactor was to produce plutonium for the chemical processing pilot plant in Building 3019, the canal was designed to be the connecting link between the reactor and the pilot plant. During the war years, natural uranium slugs were irradiated in the reactor and then pushed out of the graphite matrix into the system of ...

1992-09-01

7

Reduction of combustion emissions using hydrogen peroxide in a pilot scale combustion chamber  

Energy Technology Data Exchange (ETDEWEB)

A hydrogen peroxide injection system was designed and installed in the stack of a 5,274 million J/hr industrial pilot plant scale combustion chamber using natural gas as fuel. The concentration of peroxide in the gas stream was precisely controlled by continuous injection using an electromagnetic dosage pump, the liquid 50% peroxide solution was finely dispersed into the gases by a water cooled custom designed delivery system with a spray nozzle at the tip. Residence times between 0.1 and 1.8 seconds and concentrations of H{sub 2}O{sub 2} between 280 ppm and 4,000 ppm were used during the test runs. CEMS for total hydrocarbons, carbon monoxide, nitrogen oxides, as well as an ultrasonic gas flow monitor were used to measure the effect of hydrogen peroxide in reducing the emissions of these pollutants. Destruction removal efficiencies between 25% and 100% were observed for hydrocarbons, and concentrations of CO, as well as ...

1997-12-31

8

Experimental modelling of a pilot lignocellulosic pellets stove plant  

Energy Technology Data Exchange (ETDEWEB)

Small-scale stoves, producing heat and hot water, are suited for domestic purposes. In order to optimise their efficiency when using lignocellulosic pellets, an important task is to do research on their real performance. The general behaviour depends on many operational factors (air flow and humidity, pressure, etc), dimension and pellet characteristics (moisture, size, raw material, density, friability, etc). In this paper, the first results and general performance of a 24 kW pellet fixed bed stove pilot plant are presented. The plant has been designed to study pellet combustion in the laboratory. The main targets are to reduce emissions of pollutants and to improve energy efficiency. Different situations can be simulated and tested due to its flexible design. Temperatures, pressures, flows and emissions are measured and analysed. An extensive study of different load conditions is presented through the ...

2004-12-01

9

Recovery of Water from Boiler Flue Gas  

Energy Technology Data Exchange (ETDEWEB)

This project dealt with use of condensing heat exchangers to recover water vapor from flue gas at coal-fired power plants. Pilot-scale heat transfer tests were performed to determine the relationship between flue gas moisture concentration, heat exchanger design and operating conditions, and water vapor condensation rate. The tests also determined the extent to which the condensation processes for water and acid vapors in flue gas can be made to occur separately in different heat transfer sections. The results showed flue gas water vapor condensed in the low temperature region of the heat exchanger system, with water capture efficiencies depending strongly on flue gas moisture content, cooling water inlet temperature, heat exchanger design and flue gas and cooling water flow rates. Sulfuric acid ...

2008-09-30

10

Apollo II - Thermal use of chicken droppings - Phase II; Apollo II - Thermische Nutzung von Huehnermist, Phase II  

Energy Technology Data Exchange (ETDEWEB)

This report made for the Swiss Federal Office of Energy (SFOE) discusses the conception, planning and construction of an easy-to-operate pilot heating plant that uses chicken litter as its fuel. The plant, which is installed at a chicken farm in Boesingen, Switzerland, produces 250 - 350 kW and not only supplies heat for two chicken sheds and two households, but also provides energy for a drying plant in summer. The results of measurements made on emissions are discussed and, within the framework of an eco-balance analysis, comparisons are made between the direct use of the droppings as manure or as a fuel. The cost-effectiveness of the plant is examined and the influence of plant size and other factors discussed. Further, legal questions concerning the use of chicken litter as a fuel for heating installations are discussed; the use of the droppings as a fuel is ...

2001-07-01

11

Development of a new evaporator using hydrophobic membrane for radioactive liquid waste  

Energy Technology Data Exchange (ETDEWEB)

An evaporator using a hydrophobic membrane made from a polytetrafluoroethylene (PTFE) was developed to improve DF (Decontamination Factor) and to reduce evaporator size. The membrane distillation, provided by the evaporator, is a new technique for liquid purification. Fundamental experiments were carried out to develop the membrane filter (tube type, outer diameter, 8 mm; membrane thickness, 500 {mu}m) for radioactive liquid treatment. The continuous operation test using actual liquid waste was also made during about 3,000 h. (This is almost equal to the operation time of an actual evaporator per year.) The evaporation rate decreased with increase an operation time due to contamination of waste impurity. But the rate was recovered by washing the membrane with hot water and then drying it. DF was over 10{sup 4} which is ten times larger than that for a conventional system. A pilot plant (capacity, 200 kg-liquid waste/h) was ...

1996-10-01

12

Development of ultrafiltration and adsorbents: October 1979-March 1980  

Energy Technology Data Exchange (ETDEWEB)

Tests on a sample of trench water from the Maxey Flats burial ground effectively demonstrated the new Reverse Osmosis Pilot Plant. The effluent from the 50% salt-rejection membrane was decontaminated well enough with the exception of tritium to be discharged to the environment. The performance of the 97% salt-rejection membrane was superior to that of the 50% membrane. A breakthrough and capacity experiment was conducted with Durasil 10 on a simulated Three Mile Island solution. The maximum decontamination factor was extrapolated to be 10/sup 6/, which would reduce the cesium level of TMI water to below the discard limit. Capacity (1/DF = 0.5) was reached at 1260 column volumes. Several adsorbents were tested in the engineering columns for decontamination of cesium-bearing solutions. Under the conditions of the experiment, these adsorbents were ineffective in removing cesium from the solution.

1980-07-02

13

Technical data analysis program. Final report. [Fort Lewis and P-99; data consolidation  

Science.gov (United States)

Separate comprehensive final reports on the status of the SRC-II Demonstration Plant Design and on operating experiences at the Ft. Lewis and P-99 SRC pilot plants were prepared after the termination of those projects. However, time constraints made it impossible to consolidate all of the pilot plant data and operating experiences and relate these to the Demonstration Plant or future plant design. Most of the experimental programs during the later stages of pilot plant operation were in direct support of specific technical uncertainties identified in design work. The results of these programs would have been of substantial use in verifying or modifying design philosophy had the project proceeded. This technical data analysis project was undertaken to consolidate the pilot ...

1984-11-01

14

Development of the ELEX process for tritium separation at reprocessing plants  

International Nuclear Information System (INIS)

The ELEX process for isotopic enrichment and separation of tritium from aqueous reprocessing effluents is described. After the development of an appropriate hydrophobic catalyst and the study of the separate constituent steps of the ELEX process, an integrated bench-scale installation with a detritiation capacity of 10 mol water per hour was constructed. It comprises essentially a 1.5 kW electrolyser and two 2 cm diameter by 3 m high exchange columns. In this mini-pilot the ELEX process was successfully demonstrated by detritiating more than 1000 dm"3 water containing up to 100 mCi tritium per dm"3, which is the feed concentration expected for application of the process in a reprocessing plant. The process decontamination factor was always larger than 100 and the overall tritium balance could be kept within the experimental errors of the various measurements. Depending on the duration of the runs, the ...

1985-03-01

15

Preliminary experience with the new Harwell inactive vitrification pilot plant  

International Nuclear Information System (INIS)

The decision of the United Kingdom to adopt a policy of solidification of high level waste had led to renewed interest in vitrification. The HARVEST process chosen is an adaptation of the FINGAL concept developed at Harwell 15 years ago. Because of certain changes in engineering design and differences in the composition of the waste, additional chemical engineering data are required for HARVEST. The new inactive pilot plant has been built to provide this information. Its size is virtually full-scale and batches of glass up to 1 tonne can be manufactured in vessels of diameter up to 750mm. Five glass-making runs have been carried out. Attention has concentrated on the performance of the off-gas system which employs wet methods. Carry-over of solids occurs, primarily as a result of physical entrainment. The carry-over of synthetic fission products is improved from 2.5 to 0.1% by directing the feed down the vessel walls. Most of the entrained ...

16

AMMONIA ABSORPTION/AMMONIUM BISULFATE REGENERATION PILOT PLANT FOR FLUE GAS DESULFURIZATION  

Science.gov (United States)

The report gives results of a pilot-plant study of the ammonia absorption/ammonium bisulfate regeneration process for removing SO2 from the stack gas of coal-fired power plants. Data were developed on the effects of such operating variable in the absorption of SO2 by ammoniacal l...

17

10 MWe Solar Thermal Central Receiver Pilot Plant: solar facilities design integration. Plant electrical equipment installation. Construction package No. 11 (RADL Item 7-35)  

Energy Technology Data Exchange (ETDEWEB)

Installation of the electrical equipment at the Barstow Solar Pilot Plant is the concern of this construction package. Technical specifications for power and instrument cables, meteorological instruments, and control cables are defined. The documentation requirements are briefly discussed.

1980-07-01

19

Pilot-scale testing of pyrolysis for the volume reduction of organic waste  

Energy Technology Data Exchange (ETDEWEB)

Pilot-scale pyrolysis units have been in operation since 1980 to test the efficiency of thermal treatment of transuranic (TRU) solid waste to retrieve the TRUs and to reduce the volume of wastes such as spent solvent, spent resin, and others. These wastes are generated by reprocessing, fuel production, and utilities. NUKEM has developed a criticality-safe, ring-slab reactor to decompose solid TRU waste. The plant processes 25 kg/h with a polyvinyl chloride content up to 70%. The overall throughput (inactive) up to the spring of 1982 was 2000 kg. The decontamination factor for the reactor itself is 1000. The liquid wastes, mainly spent solvent, are cracked under nitrogen at 400 to 700/sup 0/C in a reactor that is filled by a packed bed kept in motion by a specially designed agitator. This unit was built for 15 kg/h water equivalent evaporation. Up to 1982 the unit processed 2000 kg of spent solvent (simulated) overall. The ...

1982-11-01

20

Pilot-scale testing of pyrolysis for the volume reduction of organic waste  

International Nuclear Information System (INIS)

Pilot-scale pyrolysis units have been in operation since 1980 to test the efficiency of thermal treatment of transuranic (TRU) solid waste to retrieve the TRUs and to reduce the volume of wastes such as spent solvent, spent resin, and others. These wastes are generated by reprocessing, fuel production, and utilities. NUKEM has developed a criticality-safe, ring-slab reactor to decompose solid TRU waste. The plant processes 25 kg/h with a polyvinyl chloride content up to 70%. The overall throughput (inactive) up to the spring of 1982 was 2000 kg. The decontamination factor for the reactor itself is 1000. The liquid wastes, mainly spent solvent, are cracked under nitrogen at 400 to 700"0C in a reactor that is filled by a packed bed kept in motion by a specially designed agitator. This unit was built for 15 kg/h water equivalent evaporation. Up to 1982 the unit processed 2000 kg of spent solvent (simulated) overall. The ...

21

A shallow subsurface controlled release facility in Bozeman, Montana, USA, for testing near surface CO2 detection techniques and transport models  

Energy Technology Data Exchange (ETDEWEB)

A controlled field pilot has been developed in Bozeman, Montana, USA, to study near surface CO2 transport and detection technologies. A slotted horizontal well divided into six zones was installed in the shallow subsurface. The scale and CO2 release rates were chosen to be relevant to developing monitoring strategies for geological carbon storage. The field site was characterized before injection, and CO2 transport and concentrations in saturated soil and the vadose zone were modeled. Controlled releases of CO2 from the horizontal well were performed in the summers of 2007 and 2008, and collaborators from six national labs, three universities, and the U.S. Geological Survey investigated movement of CO2 through the soil, water, plants, and air with a wide range of near surface detection techniques. An overview of these results will be presented.

2009-10-20

22

Krypton recovery pilot plant  

Energy Technology Data Exchange (ETDEWEB)

A krypton recovery pilot plant has been completed for the Power Reactor and Nuclear Fuel Development Corporation. This is the first industrial facility in the world to make practical use of development results for offgas treatment and storage from nuclear facilities. The cryogenic distillation process was adopted as a proven and reliable method to separate krypton and xenon, and to reduce gas effuents to a level so low that the decontamination factor amounts to more than 1000.

1983-01-01

23

DEVELOPMENT AND PILOT PLANT EVALUATION OF SILICA-ENHANCED LIME SORBENTS FOR DRY FLUE GAS DESULFURIZATION (JOURNAL VERSION)  

Science.gov (United States)

The paper discusses recent work on lime enhancement and testing at the bench-scale, followed by evaluation of the more promising sorbents in a pilot plant to develop low cost, retrofittable flue gas cleaning technology specifically the development of highly reactive sorbents. Con...

24

Experience on resin pyrolysis  

International Nuclear Information System (INIS)

The Swedish State Power Board has together with Nukem, Hanau, West-Germany carried out pyrolysis o powder resins in a pilot plant with a capacity of about 30 kg/hr. The pyrolysis reactor with its afterburner and offgas scrubber system has been operated under steady state condition. About 2200 kg resins have been pyrolysed under November-December 1983 and the decontamination factor for Cs has been measured. Solidification of the residues from the pyrolysis reactor and scrubber water solutions has been carried out and various recipes with cement have been tested. The pyrolysis process has high decontamination factors and no offgas problems as the operating temperature of the reactor is Low. The residues from the reactor are chemically dead and can not cause swelling problems. Compared with a normal cementation process the final waste volume will be reduced with a factor of 4 if also the scrubber water ...

25

Snow Survey & Water Supply | NRCS  

Science.gov (United States)

Programs & Services Technical Resources Land Use Soils Water Snow Survey & Water Supply Water Management Water Quality Watersheds Wetlands Air Plants & Animals Energy Climate...

2011-08-21

26

Mutagenic activity of disinfection by-products.  

UK PubMed Central (United Kingdom)

Data on raw water quality, disinfection treatment practices, and the resulting mutagenic properties of the treated water were compiled from pilot- and full-scale treatment experiments to evaluate that...Full Text Available

1986-11-01

28

Application of new corrosion-resistance superheater tubings for a 500 C, 100 Kgf/cm{sup 2}{center_dot}g high-efficiency waste-to-energy plant  

Energy Technology Data Exchange (ETDEWEB)

A two-year demonstration run of a 500 C/100kgf/cm{sup 2}{center_dot}g high-efficiency waste-to-energy pilot plant has been started from February 1998; this plant represents as the final stage of the NEDO project of development of a high-efficiency waste-to-energy plant. Alloy 625 (SB444) and 310 HCbN tubings were selected for the 3rd and 2nd superheater of the pilot plant, respectively, and ten kinds of conventional and new solid-wall tubings, weld overlayed tubings, composite tubings, and cermet spray coated tubings were tested. By means of 6000-hour field corrosion test in three typical domestic plants, material life and corrosion environment for superheater tubings installed in the pilot plant were evaluated. Also, the effect of alloying elements Cr, Ni, Mo, corrosion rate law, etc. were ...

1999-11-01

29

Environmental monitoring at Kahe Point, Oahu, Hawaii for OTEC pilot-plant development  

Energy Technology Data Exchange (ETDEWEB)

Two 40 MWe Ocean Thermal Energy Conversion (OTEC) Pilot Plant programs are in the initial phase of development near Kahe Point, Oahu, Hawaii. The two options being examined are: (1) a shelf-seated artificial island, connected via a causeway to Oahu, using stainless steel heat exchangers, with the thermal resource enhanced by effluent from a near-by power plant, ammonia working fluid and biocide (chlorine) cleaning; and (2) a shelf mount tower 1 mile off shore using submerged aluminum heat exchangers, R-22 working fluid, and slurry cleaning with biocide (chlorine) backup. Environmental Technical Requirements are described including: siting criteria; environmental design, and operational criteria; thermal resource evaluation and variability; physical, chemical, and biological data requirements; and regulatory requirements. Due to siting, design, and operational differences the proposed two pilot ...

1982-08-01

30

Development of a microbiological ammonium to nitrate recycling bioreactor for space capsules  

International Nuclear Information System (INIS)

Since 1988, the Expertise group of Molecular and Cellular Biology (MCB) is an important partner in the development of the Micro-Ecological Life Support System Alternative (MELiSSA). The MELiSSA was designed to allow a small crew to survive on an Antarctic, lunar or Mars outpost, and is a joint research project currently fostered by the European Space Agency, ESA. The MELiSSA functions through a series of five interconnected compartments, of which four are microbial bioreactors and was engineered to degrade organic waste, regenerate the outpost's atmosphere and water, and provide the crew with an additional vegetarian diet. The bioreactor of the third compartment provides the edible cyanobacteria and plants of the fourth compartment with nitrate instead of ammonium as a source of nitrogen. The two bacteria responsible for the biological transformation of ammonium to nitrate (nitrification) are Nitrosomonas europaea and Nitrobacter winogradskyi. ...

2009-09-01

31

Single cylinder testing of a high-pressure electronic pilot fuel injector for low NO sub x emission dual fuel engines. Part 1; Baseline, feasibility, and comparative testing  

Energy Technology Data Exchange (ETDEWEB)

This paper reports on current dual fuel engines utilizing standard mechanical (Bosch type) fuel injection systems set to 5--6 percent pilot delivery that do not appear capable of reducing NO{sub x} emissions much below the current minimum of 4 g/bhp-h without incurring substantial penalties in efficiency and operability. A prototype Electronic Pilot Fuel Injector (EPFI) was designed that overcomes the shortcomings of the mechanical injection system, consistently delivering 3 percent or less pilot at pressures as high as 20,000 psi. The EPFI was installed and tested in one cylinder of a standard production dual fuel engine operating at a waste water treatment facility.

1990-07-01

32

Probabilities of a catastrophic waste hoist accident at the Waste Isolation Pilot Plant  

Energy Technology Data Exchange (ETDEWEB)

This report shows the probability of a catastrophic accident involving the WIPP waste hoist system. Calculations and mitigation to reduce the probability of an accident and to minimize the impact of such an accident should be included. 10 refs., 8 figs., 4 tabs.

1990-01-01

33

Maintenance and fabrication of electronic equipment  

Energy Technology Data Exchange (ETDEWEB)

Solving the maintenance and repair problems of electronic instruments, we have supported the research and development work, and reduced operation costs of the pilot plants in KAERI. In addition, we have improved the maintainability of instruments to use effectively. 18 tabs., 17 figs., 13 refs. (Author) .new.

1995-12-01

34

Maintenance and fabrication of electronic equipment  

Energy Technology Data Exchange (ETDEWEB)

Solving the maintenance and repair problems of electronic instruments, we have supported the research and development work, and reduced operation costs of the pilot plants in KAERI. In addition, we have imposed the maintainability of instruments to use effectively. 15 tabs., 14 figs., 14 refs. (Author) .new.

1994-12-01

35

Coal liquefaction. Quarterly report, July-September 1978  

Science.gov (United States)

DOE is supporting the development of several conversion processes that are currently in the pilot plant stage. Each of these processes is described briefly and information given as to contractor, contract, funding, site and current progress. Several support projects are treated similarly. (LTN)

1979-05-01

36

Nuclear power plant liquid waste solidification system. [Japan  

Energy Technology Data Exchange (ETDEWEB)

The fundamental points to be considered in a waste treatment system for a country like Japan, where the final disposal method has not been decided and the wastes have to be stored in the power plants, are volume reduction of the wastes, safe storage of the wastes in the plant, and flexibility regarding the final disposal. A system has been developed that consists of a thin film evaporator for the direct solidification of the liquid waste, a pelletizer for producing hard pellets from the powdered wastes, a pellet storage unit, and a solidification unit for the final disposal. A pilot plant with waste treatment capacity of 200 kg/h was built in 1976 and has proved the system feasibility. This paper reports on pilot plant tests of the thin film evaporator and other components, tests on pellet deterioration during long term storage, and integrity tests on the final ...

1981-01-01

37

Nuclear power plant liquid waste solidification system  

International Nuclear Information System (INIS)

The fundamental points to be considered in a waste treatment system for a country like Japan, where the final disposal method has not been decided and the wastes have to be stored in the power plants, are volume reduction of the wastes, safe storage of the wastes in the plant, and flexibility regarding the final disposal. A system has been developed that consists of a thin film evaporator for the direct solidification of the liquid waste, a pelletizer for producing hard pellets from the powdered wastes, a pellet storage unit, and a solidification unit for the final disposal. A pilot plant with waste treatment capacity of 200 kg/h was built in 1976 and has proved the system feasibility. This paper reports on pilot plant tests of the thin film evaporator and other components, tests on pellet deterioration during long term storage, and integrity tests on the final ...

1981-02-26

38

Pilot plant studies of the bioconversion of cellulose and production of ethanol  

Science.gov (United States)

Progress is reported in several areas of research. The following cellulosic raw materials were selected for study: wheat, barley, and rice straws, rice hulls, sorghum, corn stover, cotton gin trash, newsprint, ground wood, and masonite steam-treated Douglas fir and redwood. Samples were collected, prepared, and analyzed for hexosans, pentosans, lignin, ash, and protein. Results of acid extraction and enzymatic hydrolysis are discussed. Yields of glucose, polyglucose, xylose, and arabinose are reported. Progress in process design and economic studies, as well as pilot plant process development and design studies, is summarized. (JGB)

1977-01-31

39

ALKALINE LEACH-FILTRATION PILOT PLANT TESTING OF HOMESTAKE ORE-SECTION 32  

Science.gov (United States)

Homestake Ore from the Ambrosia Lake District of New Mexico was treated in the Alkaline Leach-- Filtration Pilot Plant at Grand Junction, Colorado. Detailed information on grinding, leaching, flltration, and precipitation in connection with the processing of this ore is given. Autoclave leaching and continuous yellow cake precipitation were employed. The circuit liquors contnined organic material that was detrimental to clariflcation and precipitation and the results show that ihe ore was amenable to the Alkaline Leach--Filtration process only if a special additive was used. (auth)

1958-06-19

40

A pilot plant demonstration of the vitrification of radioactive solutions using microwave power  

Energy Technology Data Exchange (ETDEWEB)

A process has been developed that exploits the characteristics of microwave heating for the vitrification of high-level radioactive liquid waste. This process, microwave vitrification, has been successfully operated at pilot plant scale in an active cell using simulated liquid waste containing several curies of radioactivity. Excellent decontamination factors have been achieved for both volatiles and nonvolatiles with an average ruthenium decontamination factor of 490 and a gross alpha emitter decontamination factor of 100,000. Almost all the radioactivity is incorporated in a glass block.

1986-01-01

41

A pilot plant demonstration of the vitrification of radioactive solutions using microwave power  

International Nuclear Information System (INIS)

A process has been developed that exploits the characteristics of microwave heating for the vitrification of high-level radioactive liquid waste. This process, microwave vitrification, has been successfully operated at pilot plant scale in an active cell using simulated liquid waste containing several curies of radioactivity. Excellent decontamination factors have been achieved for both volatiles and nonvolatiles with an average ruthenium decontamination factor of 490 and a gross alpha emitter decontamination factor of 100,000. Almost all the radioactivity is incorporated in a glass block.

42

Pilot testing of sodium thiosulfate for oxidation/scaling inhibition in lime/limestone flue gas desulfurization systems  

Energy Technology Data Exchange (ETDEWEB)

Pilot plant tests have been conducted to evaluate sodium thiosulfate as an oxidation inhibition additive in five lime/limestone slurry flue gas desulfurization processes. It was found that the oxidation rate of absorbed sulfur dioxide (SO/sub 2/) was reduced by more than 50 percent in the presence of 100 to 200 ppm of thiosulfate ion in the scrubbing slurry. Calcium sulfate dihydrate (gypsum) scaling was eliminated and the unsaturated (with respect to gypsum) operation mode was maintained by the addition of sodium thiosulfate. Other benefits of sodium thiosulfate addition observed at the pilot plant included improvement in solids dewatering properties for limestone processes.

1985-01-01

43

Pilot testing of sodium thiosulfate  

Energy Technology Data Exchange (ETDEWEB)

Pilot plant tests have been conducted to evaluate sodium thiosulfate as an oxidation inhibition additive in five lime/limestone slurry flue gas desulfurization processes. It was found that the oxidation rate of absorbed sulfur dioxide (SO)/sub 2/ was reduced by more than 50 percent in the presence of 100 to 200 ppm of thiosulfate ion in the scrubbing slurry. Calcium sulfate dihydrate (gypsum) scaling was eliminated and the unsaturated (with respect to gypsum) operation mode was maintained by the addition of sodium thiosulfate. Other benefits of sodium thiosulfate addition observed at the pilot plant included improvement in solids dewatering properties for limestone processes and improvement in SO/sub 2/ removal efficiency for magnesium-enhanced lime/limestone processes.

1986-11-01

44

Pilot testing of sodium thiosulfate  

Energy Technology Data Exchange (ETDEWEB)

The article gives results of pilot-plant tests to evaluate sodium thiosulfate as an oxidation-inhibition additive in five lime/limestone slurry flue-gas desulfurization processes. It was found that the oxidation rate of absorbed SO/sub 2/ was reduced by more than 50% in the presence of 100-200 ppm of thiosulfate ion in the scrubbing slurry. Calcium sulfate dihydrate (gypsum) scaling was eliminated and the unsaturated (with respect to gypsum) operation mode was maintained by the addition of sodium thiosulfate. Other benefits of sodium thiosulfate addition observed at the pilot plant included improvement in solids dewatering properties for limestone processes and improvement in SO/sub 2/ removal efficiency for magnesium-enhanced lime/limestone processes.

1986-01-01

45

Pilot testing of sodium thiosulfate  

Energy Technology Data Exchange (ETDEWEB)

The article gives results of pilot-plant tests to evaluate sodium thiosulfate as an oxidation-inhibition additive in five lime/limestone slurry flue-gas desulfurization processes. It was found that the oxidation rate of absorbed SO/sub 2/ was reduced by more than 50% in the presence of 100-200 ppm of thiosulfate ion in the scrubbing slurry. Calcium sulfate dihydrate (gypsum) scaling was eliminated and the unsaturated (with respect to gypsum) operation mode was maintained by the addition of sodium thiosulfate. Other benefits of sodium thiosulfate addition observed at the pilot plant included improvement in solids dewatering properties for limestone processes and improvements in SO/sub 2/ removal efficiency for magnesium-enhanced lime/limestone processes.

1986-11-01

46

Power plants 2009. Lectures  

Energy Technology Data Exchange (ETDEWEB)

Within the Annual Conference 2009 of the VGB PowerTech e.V. (Essen, Federal Republic of Germany) from 23rd to 25th May, 2009, in Lyon (France) the following lectures were held: (1) Electricity demand, consequences of the financial and economic crisis - Current overview 2020 for the EU-27 (Hans ten Berge); (2) Status and perspectives of the electricity generation mix in France (Bernard Dupraz); (3) European electricity grid - status and perspective (Dominique Maillard); (4) Technologies and acceptance in the European energy market (Gordon MacKerran); (5) EPR construction in Finland, China, France, (Claude Jaouen); (6) EPR Flamanville 3: A project on the path towards nuclear revival (Jacques Alary); (7) Worldwide nuclear Revival and acceptance (Luc Geraets); (8) An overview on the status of final disposal of radioactive wastes worldwide (Piet Zuidema); (9) Who needs pumped storage plants? PSP are partner to grid stability and renewable energies (Hans-Christoph ...

2009-07-01

47

Power plants 2009. Lectures  

International Nuclear Information System (INIS)

Within the Annual Conference 2009 of the VGB PowerTech e.V. (Essen, Federal Republic of Germany) from 23rd to 25th May, 2009, in Lyon (France) the following lectures were held: (1) Electricity demand, consequences of the financial and economic crisis - Current overview 2020 for the EU-27 (Hans ten Berge); (2) Status and perspectives of the electricity generation mix in France (Bernard Dupraz); (3) European electricity grid - status and perspective (Dominique Maillard); (4) Technologies and acceptance in the European energy market (Gordon MacKerran); (5) EPR construction in Finland, China, France, (Claude Jaouen); (6) EPR Flamanville 3: A project on the path towards nuclear revival (Jacques Alary); (7) Worldwide nuclear Revival and acceptance (Luc Geraets); (8) An overview on the status of final disposal of radioactive wastes worldwide (Piet Zuidema); (9) Who needs pumped storage plants? PSP are partner to grid stability and renewable energies (Hans-Christoph ...

2009-09-23

48

Externally fired combined cycle for electric power generation from coal  

Energy Technology Data Exchange (ETDEWEB)

The externally fired combined cycle is emerging as an economically viable repowering options for old non-competitive coal fired steam plants. This paper describes the initial operation of a pilot plant located at Kennebunk, Maine and the initial work on the repowering of a 48MW coal fired steam plant located in Warren, PA.

1994-12-31

49

Progress on the investigation of coal water slurry fuel combustion in a medium speed diesel engine: Part 1. Ignition studies  

Energy Technology Data Exchange (ETDEWEB)

A micronized de-ashed coal-water slurry (CWS) fuel of approximately 50% coal loading has been successfully ignited and burned in one GE 7FDL engine cylinder at 1050 rpm. For this study, only about one-third of the full load fuel energy was supplied due to limitations of the fuel injection equipment used. Three types of ignition methods have been investigated. They were: Compression ignition with no ignition aid; Separate deisel pilot fuel injection to ignite the CWS fuel; Combined CWS and pilot diesel fuel injection (stratified pilot ignition). Conditions of ignition and the burning characteristics that immediately followed using the above three ignition methods are described.

1988-01-01

50

Reducing CSOs and giving the river back to the public: innovative combined sewer overflow control and riverbanks restoration of the St. Charles River in Quebec City.  

Science.gov (United States)

After the construction of its wastewater treatment plants, the City of Quebec began to implement overflow control in wet weather to ultimately meet the effluent discharge objectives, i.e. no more than two overflows per summer season in the St. Lawrence River and no more than four in the St-Charles River. After several years of studies to determine which management strategies would best suit the purpose, and to propose optimum solutions, a first project to implement optimal and predictive management in real time, called "Pilot", came to life in 1999. Construction in phases soon followed and the work was completed in the fall of 2009. As a result, requirements with regard to environmental rejects were met in two sectors, namely the St-Charles River and the Jacques-Cartier Beach, and aquatic recreational activities could resume. Meanwhile, the City also worked at giving back access to the water courses to the public by ...

2011-01-01

51

Cracking of Alloy 800 tubing in superheated steam in a solar receiver  

Energy Technology Data Exchange (ETDEWEB)

The solar central receiver at the Barstow Pilot Plant is a once-through steam boiler consisting of vertical arrays of Alloy 800 tubes. Water/steam leaks associated with tube bends near the receiver outlet were observed after 16 service months. The leaks resulted from through-wall cracks localized in the crown of tube bends operating in the temperature range from 550 to 650/sup 0/C. Initiation occurred on the ID (steam side) of the tube and propagated transgranular through the tube wall. Cracking was axial and circumferential; in general, the circumferential cracks were more severe than the axial cracks. Thick oxide layers showed on the ID of the receiver tubes; a 25-..mu..m thick oxide layer had formed on tubing which operated at 650/sup 0/C. In addition, an enhanced oxidation layer was observed along a narrow band in the crown of the tube. This band was up to five times thicker than the oxide elsewhere in the tube. All ...

1985-10-01

56

Vulnerability of soil resources to heavy metals contamination in Central Bekaa-Lebanon  

International Nuclear Information System (INIS)

Full text.Changes in land use and urbanization yield more pressure put on limited soil and water resources, including the risk of pollution with toxic heavy metals. The study area lies in the Bekaa valley totaling about 12753 ha. The valley receives from the west torrential fan deposits and a mixture of colluvial and alluvial material. The principal soil classes are Fluvisols, Cambisols, Regosols, Vertisols and Luvisols. The area is populated and also the most important agricultural part of the plain. Agriculture in the plain is being practiced mainly with cash, field crops and vegetables. The western surrounding area is being used mainly for terraced fruit trees. This Arab-German Technical Cooperation Project (ACSAD-BGR) aimed, following the ISO standards and Eikman-Klocke recommendations, at investigating the nature of the extends of soil pollution by heavy metals in two pilot areas: The central Bekaa-Lebanon and Ghouta-Damascus. Different ...

2000-11-23

57

Pilot project ''measurement of efficacy'' - biological monitoring of antimony pollution in the Munich test area using a standardized grass culture  

International Nuclear Information System (INIS)

This pilot project was carried out for the purpose of testing methods for active biological monitoring. It covered a period of three years (until September 1994), including two years of exposure. The measurements served to determine pollutant levels in plants used as animal fodder and dust-borne heavy metal concentrations in different sites and, on this basis, to obtain indirect information on human exposure. Among others, the pilot project investigated the suitability of Italian rye-grass as a biological indicator for aluminium, arsenic, cadmium, cobalt, chromium, copper, iron, mercury, magnesium, manganese, nickel, lead, platinum, antimony, titanium, and zinc. (orig./GL).

58

Does Water Deficit Stress Promote Ethylene Synthesis by Intact Plants? 1  

UK PubMed Central (United Kingdom)

The effect of plant water deficit on ethylene production by intact plants was tested in three species, beans (Phaseolus vulgaris L.), cotton (Gossypium hirsutum L.)...Full Text Available

1990-12-01

59

DOE steps up research on synthetic fuels  

Science.gov (United States)

The U.S. Department of Energy has awarded contracts to Pittsburg and Midway Coal Mining Co. and to Southern Company to design plants for the conversion of 6000 tons/day of coal by two variations of the Solvent Refined Coal (SRC) process The Federal research effort is focused on direct liquefaction by hydrogen addition, including the SRC process; the Exxon Donor Solvent (EDS) process, for which Exxon Corp. plans to scale up technology to a 250 ton/day pilot plant; and Hydrocarbon Research Inc.'s H-Coal process, for which a 2000 bbl/day pilot plant is under construction. The roles of other companies in the coal liquefaction research are also discussed.

1978-09-01

60

Project reveals CO/sub 2/ confinement problems  

Energy Technology Data Exchange (ETDEWEB)

The results of the liquid CO/sub 2/ injection pilots in the Granny's Creek field permit the following findings and conclusions: The pilots demonstrated that CO/sub 2/ can be used for tertiary recovery, and it will displace oil and form a high oil-cut bank in a watered-out reservoir. Oil production response in every case was almost immediate; and after CO/sub 2/ injection was stopped and water injection was started, the oil production declined rapidly over a period of 2-3 months to very low rates. Confinement of CO/sub 2/ to the pilot area was the principal problem. CO/sub 2/ spread rapidly to virtually all of the southern part of the reservoir of about 350 acres. Except for weather, there were practically no operational problems. Corrosion from the CO/sub 2/ was not observed. Pilot results did not demonstrate economic feasibility. The ratio of CO/sub 2/ ...

1983-01-24

61

Coal-fired combined-cycle plants are on the horizon  

Energy Technology Data Exchange (ETDEWEB)

The use of pressurised fluidized-bed coal combustion (fbc) in a combined cycle is seen as a most attractive technology for increasing the efficiency of electricity generation. The concept of pressurised fbc is described and the technical problems that are encountered in its operation and in limiting it to a gas turbine are discussed. Details are given of pilot plant facilities and current R and D programmes.

1982-06-01

62

Analyses of mixed hydrocarbon binary thermodynamic cycles for moderate temperature geothermal resources  

Energy Technology Data Exchange (ETDEWEB)

A dual-boiling isobutane cycle was selected for the present 5-megawatt (5MW) Raft River Pilot Plant to utilize the lower-temperature geothermal resources (near 300F). This study represents a second effort directed toward the design of an improved binary geothermal electric plant suitable for utilization of the lower temperature resources. 7 refs.

1981-08-01

63

Power plants 2010. Lectures  

International Nuclear Information System (INIS)

The proceedings include the following lectures: Facing the challenges - new structures for electricity production. Renewable energies in Europe - chances and challenges. Nuclear outlook in the UK. Sustainable energy for Europe. Requirements of the market and the grid operator at the electricity production companies. Perspectives for the future energy production. Pumped storage plants - status and perspectives. Nuclear power/renewable energies -partners or opponents? New fossil fired power stations in Europe - status and perspectives. Nuclear energy: outlook for new build and lifetime extension in Europe. Biomass in the future European energy market - experiences for dong energy. Meeting the EU 20:20 renewable energy targets: the offshore challenges. DESERTEC: sustainable electricity for Europe, Middle East and North Africa. New power plants in Europe - a challenge for project and quality management. Consideration of safely in new build ...

2010-09-22

64

Chemical and biological monitoring of MIOR on the pilot area of Vyngapour oil field, West Sibera, Russia  

Energy Technology Data Exchange (ETDEWEB)

The pilot area of the Vyngapour oil field allotted for MIOR tests contains three injection and three producing wells. These wells were treated in summer 1993 and 1994. Before, during, and after MIOR treatments on the pilot area the chemical compounds of injected and formation waters were studied, as well as the amount and species of microorganisms entering the stratum with the injected water and indigenous bacteria presented in bottomhole zones of the wells. The results of monitoring showed that the bottomhole zone of the injection well already had biocenosis of heterotrophic, hydrocarbon-oxidizing, methanogenic, and sulfate-reducing bacteria, which were besides permanently introduced into the reservoir during the usual waterflooding. The nutritious composition activated vital functions of all bacterial species presented in the bottomhole zone of the injection well. The formation ...

1995-12-31

65

Water chemistry and corrosion in water-steam circuits of nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

The water and steam circuits of steam generators in pressurized-water nuclear power plants are described together with the mechanism of denting, and the corrosion of spacer plates that leads to cracks in tubes by constriction. The different chemical specifications applicable to the water of the secondary circuit of the generators in normal operation and on first commissioning are listed. The results obtained and the measurements of chemical values taken in operation on the water in the secondary circuits of steam generators at Fessenheim and Bugey are presented.

1981-05-01

66

Water chemistry and corrosion in water-steam circuits of nuclear power plants  

International Nuclear Information System (INIS)

The water and steam circuits of steam generators in pressurized-water nuclear power plants are described together with the mechanism of denting, and the corrosion of spacer plates that leads to cracks in tubes by constriction. The different chemical specifications applicable to the water of the secondary circuit of the generators in normal operation and on first commissioning are listed. The results obtained and the measurements of chemical values taken in operation on the water in the secondary circuits of steam generators at Fessenheim and Bugey are presented.

67

Pilot scale hybrid processes for olive mill wastewater treatment, energy production and water reuse: comparison between fungal and electro-coagulation pre-treatments  

Energy Technology Data Exchange (ETDEWEB)

Olive oil mill wastewaters (OMW) cause disposal problems because they contain powerful pollutants such as phenolic compounds. Complete biodegradation or removal of these compounds is hardly achieved by a single treatment method. In this work, we investigated 2 integrated technologies for the treatment of the recalcitrant contaminants of OMW, allowing water recovery and reuse for agricultural purposes. (Author)

2009-07-01

68

Preliminary performance assessment for the Waste Isolation Pilot Plant, December 1992. Volume 1, Third comparison with 40 CFR 191, Subpart B  

Energy Technology Data Exchange (ETDEWEB)

Before disposing of transuranic radioactive wastes in the Waste Isolation Pilot Plant (WIPP), the United States Department of Energy (DOE) must evaluate compliance with applicable long-term regulations of the United States Environmental Protection Agency (EPA). Sandia National Laboratories is conducting iterative performance assessments of the WIPP for the DOE to provide interim guidance while preparing for final compliance evaluations. This volume contains an overview of WIPP performance assessment and a preliminary comparison with the long-term requirements of the Environmental Radiation Protection Standards for Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive Wastes (40 CFR 191, Subpart B).

1992-12-01

69

An early review of the performance assessment in the draft compliance certification application for the Waste Isolation Pilot Plant  

International Nuclear Information System (INIS)

On March 31, 1995, the US Department of Energy filed a draft application for certification of compliance with the US Environmental Protection Agency (USEPA) to show the Waste Isolation Pilot Plant's compliance with the USEPA's environmental standards, making the application the first of its kind. Demonstration of compliance is by performance assessment. This paper is an early review of the performance assessment in the draft application, by the Environmental Evaluation Group, an oversight group. The performance assessment in the draft application is incomplete. Not all relevant scenarios have been analyzed. The calculation of potential consequences often does not use experimental data but rather estimates by workers developing additional data. The final compliance application, scheduled for October 1996 needs to consider additional scenarios, and be fully based on experimental data.

70

Annual report on heavy water reactor fuel fabrication  

Energy Technology Data Exchange (ETDEWEB)

The CANDU-type nuclear fuel localization project started in 1981, and mass-production system completed in 1987 through the pilot scale demonstration of fuel manufacturing. Since the completion of the mass-production system, about 24,000 fuel bundles (450 ton-U) had been delivered to Wolsung Nuclear Power Plant by the end of 1992, according to the fuel supply contracts with KEPCO. The superiority of KAERI-made nuclear fuel has been demonstrated by having achieved the highest utilization factor in the world in 1992. In 1993, as contracted, 4,824 fuel bundles well fabricated and delivered to Wolsung Nuclear Power Plant. The process improvement, quality control, safety management, safeguards of nuclear materials and various kinds of audits have also been performed in the course for fuel manufacturing. Especially in 1993, the difficulties of the reduction of participating work-force were overcome by improving the manufacturing ...

1994-03-01

71

Thin-film evaporator recovers solvents continuously  

Energy Technology Data Exchange (ETDEWEB)

Reclaimed Energy Company, Inc., Connersville, IN, receives waste generated from a wide variety of industrial applications which include paint, printing and degreasing companies. The wastes are stored in separate tanks and then distilled in batches (pot distillation). The recovered solvents can be returned to the originator. The residue, left after the solvents are distilled, is disposed of using an environmentally safe, economical procedure. The company worked with an engineering and fabrication firm to develop a continuous processing system that employs a mechanically agitated thin-film evaporator to distill the solvents. Successful performance of the evaporator was ensured by processing samples of solvents through the evaporator manufacturer's pilot plant facilities before the full-sized system was designed. Reclaimed Energy Company, Inc., has realized a number of advantages by going from pot distillation to the agitated thin-film ...

1985-11-01

72

Microwave drying of fine coal  

Energy Technology Data Exchange (ETDEWEB)

Drying fine coal by microwaves is now being considered as a viable option by some coal producers. The interest in microwaves is due to problems encountered with current thermal or hot-air drying methods. The technical feasibility of drying minus 5mm coal fines by microwaves was demonstrated using pilot-scale continuous processing system. Results showed that water absorbs microwave energy significantly; but coal does not. Secondly, microwave energy heats only the water, unlike existing drying methods, which heat both water and coal. Finally, the method was found to be energy efficient and minimised the generation of dust.

1989-03-01

73

Conception and design of steam power plants  

International Nuclear Information System (INIS)

The manual presents the fundamentals of thermodynamics and fluid mechanics, the main components of steam power plants, and the power generation process. The following concepts and subjects are discussed at length: steam generator; steam turbines; turbogenerators; condensers; cooling technology; water/steam cycle and water treatment; design data of fossil-fuelled power plants; design and optimisation of nuclear power plant thermodynamics; pipelines and fittings; control systems in steam power plants; connection to the electricity grid and self-supply of thermal power plants; power plant transformer concepts and definitions. (HAG).

74

A field demonstration of the microbial treatment of sour produced water  

Energy Technology Data Exchange (ETDEWEB)

The potential for detoxification and deodorization of sulfide-laden water (sour water) by microbial treatment was evaluated at a petroleum production site under field conditions. A sulfide-tolerant strain of the chemautotroph and facultative anaerobe, Thiobacillus denitrificans, was introduced into an oil-skimming pit of the Amoco Production Company LACT 10 Unit of the Salt Creek Field, Wyoming. Field-produced water enters this pit from the oil/water separation treatment train at an average flowrate of 5,000 bbl/D (795 m{sup 3}/D) with a potential maximum of 98,000 bbl/D (15,580 m{sup 3}/D). Water conditions at the pit inlet are 4,800 mg/l TDS, 100 mg/l sulfide, pH 7.8, and 107{degrees}F. To this water an aqueous solution of ammonium nitrate and diphosphorous pentoxide was added to provide required nutrients for the bacteria. The first 20% of the pit was aerated ...

1995-12-31

75

Resource Conservation and Recovery Act, Part B permit application [for the Waste Isolation Pilot Plant (WIPP)]. Volume 4, Revision 1.0  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy is currently constructing the Waste Isolation Pilot near Carlsbad, New Mexico. The full-scale pilot plant will demonstrate the feasibility of the safe disposal of defense-related nuclear waste in a bedded salt formation at a depth of 2160 feet below the surface. WIPP will provide for the permanent storage of 25,000 cu ft of remote-handled (RH) transuranic waste and 6,000,000 cu ft of contact-handled (CH) transuranic waste. This paper covers the major mechanical/structural design considerations for the waste hoist and its hoist tower structure. The design of the hoist system and safety features incorporates state-of-the-art technology developed in the hoist and mining industry to ensure safe operation for transporting nuclear waste underground. Also included are design specifications for VOC-10 monitoring system.

1991-12-31

76

CWM production by low rank coals upgrading  

Energy Technology Data Exchange (ETDEWEB)

A 8.4 t/d pilot plant was completed in November 1994. Experimental operation for continuous tests have been carried out since December 1994. Two kinds of Indonesian sub-bituminous coals and an Australian lignite were upgraded and slurrified by the end of 1995. Typical pilot test results, such as coal concentration of upgraded sub-bituminous CWM of 65% and 4,700 kcal/kg heating value, were better than the authors expected. And subsequent combustion test in a 200 kg/h furnace was also successfully completed, with results showing very good combustibilities. This R and D is now in its final year, and the authors are conducting combustion tests on a big burner and gasification test, which will be carried out until March 1996. The test results from the pilot plant so far confirm the validity and economic feasibility of the upgrading and CWM production technology to promote the use of low ...

1996-12-31

77

Universal model for water costs of gas exchange by animals and plants  

UK PubMed Central (United Kingdom)

For terrestrial animals and plants, a fundamental cost of living is water vapor lost to the atmosphere during exchange of metabolic gases. Here, by bringing together previously developed models for...Full Text Available

2010-05-04

78

Quality assurance requirements for packaging, shipping, receiving, storage, and handling of items for water-cooled nuclear power plants (Revision 1) - October 1976  

International Nuclear Information System (INIS)

This guide describes an acceptable method of complying with the Commission's regulations with regard to the quality assurance requirements for the packaging, shipping, receiving, storage, and handling of items for water-cooled nuclear power plants.

79

Do Woody Plants Operate Near the Point of Catastrophic Xylem Dysfunction Caused by Dynamic Water Stress? 1  

UK PubMed Central (United Kingdom)

We discuss the relationship between the dynamically changing tension gradients required to move water rapidly through the xylem conduits of plants and the proportion of conduits lost through embolism...Full Text Available

1988-11-01

80

Major roles of water chemistry for safe and reliable nuclear power plant operation. Research committee on water chemistry standard  

International Nuclear Information System (INIS)

The research committee of the Atomic Energy Society of Japan on water chemistry standard aims at establishing the private standard of water chemistry of nuclear power plants. The committee gathers up 'BWR water chemistry management manual', 'PWR primary system water chemistry management manual' and 'PWR water chemical analysis standard method', and furthermore aims at the standardization of those in future. Looking back on the committee's activities for the past four years, latest results of research of water chemistry mainly contributing to safe and reliable nuclear power plants were described with the future perspective of water chemistry and a demanded break-through. (T.T.)

2007-05-01

81

Evaluation of the fluid force in main feed water control valve for APWRs  

International Nuclear Information System (INIS)

... 2432 v. 43(1) SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS

2006-01-01

83

Engineering Development of Coal-Fired High-Performance Power Systems  

Energy Technology Data Exchange (ETDEWEB)

A High Performance Power System (HIPPS) is being developed. This system is a coal-fired, combined cycle plant with indirect heating of gas turbine air. Foster Wheeler Development Corporation and a team consisting of Foster Wheeler Energy Corporation, Bechtel Corporation, University of Tennessee Space Institute and Westinghouse Electric Corporation are developing this system. In Phase 1 of the project, a conceptual design of a commercial plant was developed. Technical and economic analyses indicated that the plant would meet the goals of the project which include a 47 percent efficiency (HHV) and a 10 percent lower cost of electricity than an equivalent size PC plant. The concept uses a pyrolysis process to convert coal into fuel gas and char. The char is fired in a High Temperature Advanced Furnace (HITAF). The HITAF is a pulverized fuel-fired boiler/air heater where steam is generated and gas turbine ...

2000-12-31

84

State of coal gasification for production of fuel gas and synthesis gas  

Energy Technology Data Exchange (ETDEWEB)

The fundamental principles of coal gasification are discussed including the reactions, their course and influencing parameters. Said principles are illustrated considering heat balance as well as process performance. Coal gasification processes are presented which are under development on a pilot plant scale or which are approved on an industrial scale.

1984-04-01

85

Revival and status of coal liquefaction technology in Germany  

Energy Technology Data Exchange (ETDEWEB)

In Germany, the oil crisis of 1979 initiated a revival of coal liquefaction technologies which had already seen industrial-scale application in the early 1940s. The paper describes various coal liquefaction research projects carried out and pilot plants constructed in Germany since then. 18 figs., 1 tab.

1998-07-01

86

Oceans 82 conference record: Industry, government, education. partners in progress  

Energy Technology Data Exchange (ETDEWEB)

Separate abstracts were prepared for 20 papers in this conference report and includes all papers in the ''engineering'' section (program E). Ocean thermal energy conversion (OTEC), moorings, cables, corrosion protection, corrosion testing, coatings, offshore platforms, pipelines, OTEC models and pilot plants, and energy transfer are topics discussed.

1982-01-01

87

Geothermal energy in Denmark. The Committee for Geothermal Energy of the Danish Energy Agency  

International Nuclear Information System (INIS)

The Danish Energy Agency has prepared a report on the Danish geothermal resources and their contribution to the national energy potential.Environmental and socio-economic consequences of geothermal power systems implementation are reviewed. Organizational models and financing of geothermal-seismic research are discussed, and the Committee of the Energy Agency for Geothermal Energy recommends financing of a pilot plant as well as a prompt elucidation of concession/licensing problems. (EG).

88

EFFECT OF DISSOLVED SOLIDS ON LIMESTONE FGD (FLUE GAS DESULFURIZATION) SCRUBBING CHEMISTRY  

Science.gov (United States)

The paper gives results of experiments in a 0.1 MW pilot plant to determine the effects of high concentrations of chloride ions and dissolved salts on flue gas desulfurization (FGD) scrubbing chemistry, both in the natural and forced oxidation modes of operation. (Note: The tight...

89

ECONOMICS OF RETROFITTING BIG RIVERS ELECTRIC CORPORATION'S LIME-BASED FGD (FLUE GAS DESULFURIZATION) SYSTEM TO ORGANIC-ACID-ENHANCED LIMESTONE OPERATIONS  

Science.gov (United States)

The report describes the site specific changes required to convert an existing lime FGD system to a limestone system enhanced by dibasic acid (DBA) or adipic acid, and the costs of making such a change. In 1982-83, pilot plant tests were conducted at the R. D. Green Station of Bi...

90

Development of pressurized internally circulating fluidized-bed (PICFB) technology  

Energy Technology Data Exchange (ETDEWEB)

After the completion of the 4MWth pilot plant of the Pressurizied Internally Circulating Fluidized-bed Boiler (PICFB), a total of 15 test runs, amounting to 2280 hours of operation, were concluded. The test results have confirmed the superior operating performance. Additionally, Ebara plans to develop a Pressurized Internally Circulating Fluidized-bed Gasifier (PICFG or Advanced PICFB). 8 figs.

1998-07-01

91

Developing DB system of piping reliability  

Energy Technology Data Exchange (ETDEWEB)

Developing DB system of piping reliability including the population data and service history of damaged piping for pilot power plant. Total weld counts of shop welds, field welds and welds for measuring instruments for 14 systems of Kori unit 3. Total weld counts of shop welds, field welds and welds for measuring instruments for 12 systems of Wolsung unit 2.

2005-03-15

92

Desulphurization of hot reducing gases in the entrained bed reactor  

Energy Technology Data Exchange (ETDEWEB)

Using an experimental pilot plant, designed and built for the tests, the influence of the following parameters was determined: desulphurization of the test gas, temperature, residence time in the reactor tube, concentration of the hydrogen sulphide and desulphurization agent, size of the particles which comprise the agent and composition of the gas. Allowance was made for the effect of calcination and carbonisation. Desulphurization was carried out with limestone on a gaseous mixture of CO and H/sub 2/. A mathematical description of the test findings and yield is presented. 8 refs.

1986-08-01

93

DISPOSAL OF FLUE GAS DESULFURIZATION WASTES: EPA SHAWNEE FIELD EVALUATION  

Science.gov (United States)

The report summarizes results of the flue gas desulfurization (FGD) waste disposal field evaluation project sponsored by EPA at TVA's Shawnee steam plant, Paducah, KY. This pilot-scale project, initiated in 1974 and completed in September 1980, evaluated methods and costs for dis...

94

Coal liquefaction. [United Kingdom  

Energy Technology Data Exchange (ETDEWEB)

The aim of British coal liquefaction research is to produce premium products such as transport fuels and chemical feedstocks. Government support has been promised for two 25 tpd pilot plants. Badger estimate that the finished products would cost 25% more than petroleum products. Countries with no indigenous oil are likely to commence commercial coal liquefaction soon.

1980-12-18

95

Coal liquefaction. Quarterly report, January--March 1976  

Science.gov (United States)

ERDA's coal liquefaction program is reviewed, especially the progress with several pilot plant operations. Other items involve the possible recovery of organic chemicals from coal liquids, the filtration of coal liquids, some experiments on hydrogenation and carbonization, and renovation of the Cresap materials and equipment test facility. (LTN)

1976-01-01

96

Achieving more reliable operation of turbine generators at nuclear power plants by improving the water chemistry of the generator stator cooling system  

British Library Electronic Table of Contents (United Kingdom)

Ways of improving the water chemistry used in the turbine generator stator?s cooling systems at Russian nuclear power plants are considered. Data obtained from operational chemical monitoring of indicators characterizing the quality of cooling water in the turbine generator stator cooling systems of operating power units at nuclear power plants are presented.

2011-01-01

97

Radiological hazards in uranium mines and a yellow-cake plant in Turkey  

Energy Technology Data Exchange (ETDEWEB)

Radiological hazard in uranium mining and milling operations are primarily due to exposure to external beta and gamma radiation as well as to airborne radionuclides which consist of radon and its short-lived daughter products. In May 1981 a radiological survey programme was performed in order to make a general assessment of the radiation hazards associated with the uranium mines and the Uranium Pilot Plant operated by the M.T.A. Institute in the Koprubasi district of the Manisa province. In this paper a preliminary radiological risk evaluation attempt is presented based on the radiation and radioactivity measurements performed in this district in May 1981.

1984-06-01

98

Development of RCM analysis software for Korean nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

A software called KEPCO RCM workstation (KRCM) has been developed to optimize the maintenance strategies of Korean nuclear power plants. The program modules of the KRCM were designed in a manner that combines EPRI methodologies and KEPRI analysis technique. The KRCM is being applied to the three pilot system, chemical and volume control system, main steam system, and compressed air system of Yonggwang Units 1 and 2. In addition, the KRCM can be utilized as a tool to meet a part of the requirements of maintenance rule (MR) imposed by U.S. NRC. 3 refs., 4 figs. (Author)

1998-12-31

99

Nodule and Leaf Nitrate Reductases and Nitrogen Fixation in Medicago sativa L. under Water Stress  

UK PubMed Central (United Kingdom)

The effect of water stress on patterns of nitrate reductase activity in the leaves and nodules and on nitrogen fixation were investigated in Medicago sativa L. plants watered 1 week...Full Text Available

1982-02-01

100

In vivo Visualization of the Water-refilling Process in Xylem Vessels Using X-ray Micro-imaging  

UK PubMed Central (United Kingdom)

Background and AimsXylem vessels containing gases (embolized) must be refilled with water if they are to resume transport of water through the plant, so refilling is of great importance...Full Text Available

2008-03-01

101

Tests with cleaned and uncleaned gas on a pilot plant. Final report  

Energy Technology Data Exchange (ETDEWEB)

The possibilities for heat recovery in a cast iron melting furnace were studied. A cupola furnace which produces 40 tonnes steel per hour, produces 25,000 Nm/sup 3//h of flue gases which contain 16-22% CO. Taking into account the heat losses at the chimney where fumes are cooled to 200/sup 0/C the recoverable heat is about 12.4-10/sup 6/ kcal/h which mainly consists of combustion heat in CO. This study showed that the heat can be used for the production of electricity, which will be used in the plant. Recovery of 87 kWh of electricity per tonne of steel produced is possible. A steam turbine driven generator of 3.5 MW will be required. The combustion of the low calorific gas (approximately 400 kcal/Nm/sup 3/) has been studied and gave positive results: wet CO gas can be burnt without addition of methane and preheating of air is not required. The pilot plant consisting of a thermic system (combustion chamber and equipment to ...

1986-01-01

102

Preparation and applications of wood-polyester composites  

International Nuclear Information System (INIS)

Optimum processing parameters were searched for the pilot-scale production of wood-polyester composites by irradiation of resin-impregnated wood material. The radiation initiation of the following systems were examined in wood and without wood matrix: methyl methacrylate, mixture of styrene and acrylonitryle, and their combination with unsaturated polyester. In the most cases the over-all rate of the complete polymerization process in wood matrix is proportional to the square root of the initiation rate. The parameters of the radiation technology of wood-polyester composites have been determined, using 260 TBq (7 kCi) "6"0Co radiation source. A pilot plant has been constructed using an underwater irradiation system of 1.85 PBq (50 kCi) "6"0Co. The successful production rate of 200 kg wood-polyester composite per day, as well as the application tests have demonstrated the technical feasibility of this new structural ...

1982-01-01

103

Review of the WIPP draft application to show compliance with EPA transuranic waste disposal standards  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the New Mexico Environmental Evaluation Group (EEG) is to conduct an independent technical evaluation of the Waste Isolation Pilot Plant (WIPP) Project to ensure the protection of the public health and safety and the environment. The WIPP Project, located in southeastern New Mexico, is being constructed as a repository for the disposal of transuranic (TRU) radioactive wastes generated by the national defense programs. The EEG was established in 1978 with funds provided by the U.S. Department of Energy (DOE) to the State of New Mexico. Public Law 100-456, the National Defense Authorization Act, Fiscal Year 1989, Section 1433, assigned EEG to the New Mexico Institute of Mining and Technology and continued the original contract DE-AC04-79AL10752 through DOE contract DE-AC04-89AL58309. The National Defense Authorization Act for Fiscal Year 1994, Public Law 103-160, continues the authorization. EEG performs independent technical ...

1996-03-01

104

Off-gas behavior in the HARVEST pot vitrification process  

Energy Technology Data Exchange (ETDEWEB)

A summary of the off-gas behavior in the HARVEST pot vitrification process is presented. Experimental runs were carried out on 3 representative wastes (MAGNOX - thermal reactor, metal fuel, THORP - thermal oxide fuel and PFR - fast reactor oxide fuel) using 2 methods of feeding the glass-formers (slurry and crizzle). Materials were carried over from the vitrification vessel into the off-gas system by entrainment supplemented by volatilization. The main volatile elements were Ru, B, Cs. Some volatility was also shown by Na and Li. The overall behavior of the off-gas was consistent with the presence in it of 5 separate aerosols of particulate matter. Sources of entrainment gave rise to 3 aerosols, and a further 2 aerosols were formed as a result of chemical reaction (Ru) and condensation (Cs) proceses involving the volatile species. Entrainment was enhanced when the feed contained free alkali nitrate. The Ru volatility correlated directly with the amount of salt nitrates in the feed. The ...

1983-06-01

105

Presence of pathogenic microorganisms in power-plant cooling waters. Report for October 1, 1979-September 30, 1981  

Energy Technology Data Exchange (ETDEWEB)

Cooling waters from eleven geographically disparate power plants were tested for the presence of Naegleria fowleri and Legionella pneumophila (LDB). Control source waters for each plant were also tested for these pathogens. Water from two of the eleven plants contained pathogenic Naegleria, and infectious Legionella were found in seven of the test sites. Pathogenic Naegleria were not found in control waters, but infectious Legionella were found in five of the eleven control source water sites. Concentrations of nitrite, sulfate, and total organic carbon correlated with the concentrations of LDB. A new species of Legionella was isolated from one of the test sites. In laboratory tests, both Acanthamoeba and Naegleria were capable of supporting the growth of Legionella pneumophila.

1982-10-01

106

[Pilot-plant testing for flue gas desulfurization and dust removal by activated coke].  

Science.gov (United States)

A developed flue gas desulfurization and dust removal process with a cross-flow moving bed filled with activated coke (AC) was tested on a pilot scale with the gas treatment capacity of 1000 mg x h(-t). The results show that a easy-operating and stable-running pilot-scale testing equipment can be reached, and under the conditions of testing space velocity, the feed gas temperature of 120 degrees C, SO2 concentrations of 3232-6006 mg x m(-3) and dust concentration of 89.3-1599.7 mg x m(-3), the high efficiency of flue gas desulfurization and dust removal is reached with the purity of dust less than 50 mg x m(-3). In the technology, the spent AC was regenerated by heating, and the SO2 concentration in the desorption gas is about 40.1%, which can be efficiently recovered as a sulfur resource. Favorable economy benefit can be reached by using the process. PMID:16850821

2006-05-01

107

Pilot studies at industrial sources with an electrostatic precipitator having wide plate spacing. Pilotuntersuchungen an industriellen Quellen mit einem elektrischen Abscheider grosser Gassenweite  

Energy Technology Data Exchange (ETDEWEB)

With a pilot electrostatic precipitator having wider plate spacings than usual tests were performed under industrial conditions. In the two-section two-duct pilot precipitator with a precipitation area of 60 m/sup 2/ the plate spacing was increased up to 1,000 mm. As gas velocities values between 0.5 and 2.0 m/s were selected. The precipitator was tested with the flue gases of a coal-fired power station and in the room dedustion of an iron ore sintering plant. Starting with a plate spacing of 250 mm increasing the spacing results initially in a small increase of the precipitation rate. After reaching a maximum the rate decreases and finally with passing a critical spacing it goes below the initial value. Dedusting flue gases the spacing with the maximum and the critical spacing depend on the gas velocity. Cost analyses demonstrate that increasing the up to now used plate spacings may led to considerable savings. Depending ...

1983-01-01

108

Hydroelectric and pumped storage plants  

Energy Technology Data Exchange (ETDEWEB)

All power plant engineers face the problem of peak power demands. Pumped storage plants are used to generate peak load power by pumping up water utilizing off-peak energy of hydrothermal and thermonuclear plants. This is the first accessible text/reference to cover hydroelectric power generation with emphasis on engineering to meet peak power demands by means of pumped storge plants, tidal power plants, and low head power generation. Text covers hydrology, mechanical and electrical equipment, accessories such as penstocks and valves, and civil engineering considerations. Contains descriptions of several existing plants. Includes 200 diagrams and 50 photographs.

1989-01-01

109

Hydroelectric and pumped storage plants  

Energy Technology Data Exchange (ETDEWEB)

All power plant engineers face the problem of peak power demands. Pumped storage plants are used to generate peak load power by pumping up water utilizing off-peak energy of hydrothermal and thermonuclear plants. This is a reference to cover hydroelectric power generation with emphasis on engineering to meet peak power demands by means of pumped storage plants, tidal power plants, and low head power generation. Text covers hydrology, mechanical and electrical equipment, accessories such as penstocks and valves, and civil engineering considerations. Contains descriptions of several existing plants. Includes 200 diagrams and 50 photographs.

1988-01-01

110

Regeneration of zinc anodes for the Electric Fuel{reg_sign} zinc-air refuelable EV battery system  

Energy Technology Data Exchange (ETDEWEB)

The Electric Fuel Limited (EFL) refuelable zinc-air battery system is currently being tested in a number of electric vehicle demonstration projects, the largest of which is a field test of zinc-air postal vans sponsored chiefly by Deutsche Post AG (the German Post Office). The zinc-air battery is not recharged electrically, but rather is refueled through a series of mechanical and electrochemical steps that will require a special infrastructure in commercial application. As part of the German Post Office field test program, Electric Fuel designed and constructed a pilot zinc anode regeneration plant in Bremen, Germany. This plant is capable of servicing up to 100 commercial vans per week, which is adequate for the field test vehicle fleet. This paper will describe the design and operation of each of the areas and devices within the plant.

1997-12-31

111

Anodic corrosion protection of sulphuric acid plants with regard to the recovery of heat  

Energy Technology Data Exchange (ETDEWEB)

Anodic protection makes it possible to keep materials which can be passivated in a 'passive' state or to bring them into this state, even in unfavourable conditions. With sulphuric acid concentrations of 93-99% this method permits the use of inexpensive, stainless austenitic steels, e.g. 1.4541 and 1.4591, at temperatures of up to 160/sup 0/C. The temperature range from 120/sup 0/C, in particular, is suitable for heat recovery. Anodic protection by the APR-system provides safe and low-cost protection for air coolers and bare tube coolers in sulphuric acid plants. The results of laboratory, pilot plant and commercial trials show that in this way a safe operation of sulphuric acid coolers is possible on a long-term basis.

1982-05-01

112

The numerical simulation on low-level radioactive waste water, low-temperature cooling water drained effect of implement from the Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

In this paper, we calculated the radioactive concentration distribution of radioactive waste water, the temperature distribution of drained cooling water and the effect of implement from the Daya Bay Nuclear Power Plant on nearby waters range, discussed and analysed some problems of computational results and computation with Alternating Direction Implicit Method (ADI). The contents of the article included: the establishment of two-dimension tidal current equation, radioactive waste water pollutant dispersion equation and cooling water heat convection diffusion equation, the numerical difference calculation model of tidal current field, concentration field as well as temperature field, effect impingement with ADI method, numerical calculation results. The result of research showed that: when the Daya Bay Nuclear Power Plant is on normal ...

113

Comparison of levels of trace elements extracted from fly ash and levels found in effluent waters from a coal-fired power plant  

Science.gov (United States)

Trace elements were extracted from a coal-fired power plant electrostatic precipitator ash with nitric acid, hydrochloric acid, citric acid, redistilled water, and ammonium hydroxide as extractants. Effluent waters at this plant were sampled to assess the elevation of trace element concentrations compared with intake waters. The results showed a positive correlation between those elements most extractable by water (B, F, Mo, and Se) or acid (As, B, Cd, F, Mo, and Se) and those elements most elevated in effluent waters (As, B, F, Mo, and Se).

1977-10-01

114

Solar thermal electricity in 1998: An IEA/SolarPACES summary of status and future prospects  

Energy Technology Data Exchange (ETDEWEB)

Research and development activities sponsored by countries within the International Energy Agency`s solar thermal working group. SolarPACES, have helped reduce the cost of solar thermal systems to one-fifth that of the early pilot plants. Continued technological improvements are currently being proven in next-generation demonstration plants. These advances, along with cost reductions made possible by scale-up to larger production and construction of a succession of power plants, have made solar thermal systems the lowest-cost solar energy in the world and promise cost-competitiveness with fossil-fuel plants in the future. Solar thermal technologies are appropriate for a wide range of applications, including dispatchable central-station power plants where they can meet peak-load to near-base-load needs of a utility, and distributed, modular power ...

1998-07-01

115

Ionic liquids for post combustion CO{sub 2} absorption  

Energy Technology Data Exchange (ETDEWEB)

The use of ionic liquids for post combustion capture was discussed. Compared to other solvents, ionic liquids can be used in higher concentrations. Other advantages include the large variation in physical and chemical properties and the non measurable vapor pressure. In this study, 78 different ionic liquids were synthesized and the carbon dioxide absorption rate was measured. The most promising ionic liquids were produced and various tests were made to identify the most suitable absorption solvent. The vapor-liquid equilibrium curve was measured between 40 and 110 degrees C. Pilot plant tests with MEA and one selected ionic liquid test with 30 per cent MEA at the pilot plant at the EVNs Duernrohr Power Station in Lower Austria are running successfully with a capture performance of approximately 87 per cent. The experiments will provide a direct comparison of the energy demand and capture performance ...

2009-07-01

116

Final phase testing and evaluation of the 500 kW direct contact pilot plant at East Mesa  

Energy Technology Data Exchange (ETDEWEB)

The testing performed during the last phase of the geothermal direct contact heat exchanger program utilizing the 500 kW pilot plant provided more insight into the capabilities and limits of the direct contact approach and showed that more work needs to be done to understand the inner workings of a large direct contact heat exchanger if they are to be modeled analytically. Testing of the column demonstrated that the performance was excellent and that the sizing criteria is conservative. The system operated smoothly and was readily controlled over a wide range of operating conditions. Performance evaluation showed pinch differentials of 4/sup 0/F or less and better than predicted heat transfer capability. Testing during this final phase was directed towards establishing the limits of the column to transfer heat. The working column height was shortened progressively to approximately 16 feet from a design length of 28 feet. The short column ...

1983-12-01

117

Application of SGFM technology to alternate feedstocks. Phase III  

Energy Technology Data Exchange (ETDEWEB)

The Synthesis Gas From Manure (SGFM) pilot plant was constructed at Texas Tech University to evaluate the gasification of cattle feedlot manure. A study of gas yield and composition as a function of operating conditions was performed. This report presents the results of a comparison of feedstocks other than manure in the pilot plant. Oak sawdust was the superior feedstock tested in terms of both gas yield and operability. Corn stover and mesquite were comparable and presented some handling problems. Cotton gin trash was unacceptable due to low-temperature ash fusion in the reactor. The gas yield from oak sawdust varied from 0.8 to 1.7 1/gm DAF feed at average temperatures of 650 to 770/sup 0/C. The gas contained approximately 15% hydrogen and 40% carbon monoxide by volume. It also contained 5 to 8% methane and 2 to 5% ethylene. All of these results were obtained using steam and air as the gasifying ...

1980-01-01

118

A pilot application of risk-based methods to establish in-service inspection priorities for nuclear components at Surry Unit 1 Nuclear Power Station  

International Nuclear Information System (INIS)

As part of the Nondestructive Evaluation Reliability Program sponsored by the US Nuclear Regulatory Commission, the Pacific Northwest Laboratory is developing a method that uses risk-based approaches to establish in-service inspection plans for nuclear power plant components. This method uses probabilistic risk assessment (PRA) results and Failure Modes and Effects Analysis (FEMA) techniques to identify and prioritize the most risk-important systems and components for inspection. The Surry Nuclear Power Station Unit 1 was selected for pilot applications of this method. The specific systems addressed in this report are the reactor pressure vessel, the reactor coolant, the low-pressure injection, and the auxiliary feedwater. The results provide a risk-based ranking of components within these systems and relate the target risk to target failure probability values for individual components. These results will be used to guide the development of ...

120

Wastewater treatment of industrial effluent using activated dolomite adsorption  

Environmental Research Database

SummaryInitial results from the use of activated dolomite from QUESTOR project L1 have proved extremely encouraging in terms of metallic ion (also phosphate, nitrate and dye) removal from wastewater, with capacities in some instances in excess of commercially available activated carbons.This new project involves investigating actual plant effluent in laboratory scale columns and the design of a pilot scale rig for on site trials. The project also involves investigating disposal options and an economic [continued...

2007-01-01

121

Quality assurance requirements for certification of TRU waste for shipment to the WIPP  

International Nuclear Information System (INIS)

This document presents the basic Quality Assurance (QA) requirements which shall be included in the Quality Assurance Program established by sites planning to certify Transuranic (TRU) Waste to Waste Isolation Pilot Plant (WIPP) Waste Acceptance Criteria. These QA requirements were modeled after ANSI/ASME NQA-1-1979. The application of quality assurance to Waste Certification Programs is required by WIPP-DOE-069 and DOE Order 5700.6A, as implemented by DOE Order AL 5700.6A.

122

Materials testing and failure analysis activities at the Wilsonville Advanced Coal Liquefaction Research and Development Facility  

Science.gov (United States)

Oak Ridge National Laboratory (ORNL) has for over ten years provided materials testing and failure analysis services to various coal conversion and utilization facilities in the United States. ORNL was involved in these types of activities at all four of the major coal liquefaction pilot plants. This paper presents a summary of activities at Wilsonville over the past two and one-half years. Some details of these activities are discussed below. Failure analysis of elastomers, stainless steels, and alloys is discussed. 6 refs., 9 figs., 13 tabs.

1989-01-01

123

Intermediate scale borehole (Room C): In situ data report (January 1989--June 1993)  

Energy Technology Data Exchange (ETDEWEB)

Data are presented from the intermediate scale borehole test, an in situ test fielded in the pillar separating Rooms C1 and C2 at the Waste Isolation Pilot Plant (WIPP). The test was to provide data on the influence of scale, if any, on the structural behavior of underground openings in salt. These data include selected fielding information, test configuration, instrumentation activities, and comprehensive results from a large number of gages. Construction of the test began in December 1989, with the drilling of the intermediate scale borehole in December 1990. Gage data in this report cover the period from January 1989 through June 1993.

1994-11-01

124

Fundamental investigation of duct/ESP phenomena. Final report  

Energy Technology Data Exchange (ETDEWEB)

Radian Corporation was contracted to investigate duct injection and ESP phenomena in a 1.7 MW pilot plant constructed for this test program. This study was an attempt to resolve problems found in previous studies and answer remaining questions for the technology using an approach which concentrates on the fundamental mechanisms of the process. The goal of the study was to obtain a better understanding of the basic physical and chemical phenomena that control: (1) the desulfurization of flue gas by calcium-based reagent, and (2) the coupling of an existing ESP particulate collection device to the duct injection process. Process economics are being studied by others. (VC)

1991-10-21

125

Fundamental investigation of duct/ESP phenomena  

Energy Technology Data Exchange (ETDEWEB)

Radian Corporation was contracted to investigate duct injection and ESP phenomena in a 1.7 MW pilot plant constructed for this test program. This study was an attempt to resolve problems found in previous studies and answer remaining questions for the technology using an approach which concentrates on the fundamental mechanisms of the process. The goal of the study was to obtain a better understanding of the basic physical and chemical phenomena that control: (1) the desulfurization of flue gas by calcium-based reagent, and (2) the coupling of an existing ESP particulate collection device to the duct injection process. Process economics are being studied by others. (VC)

1991-10-21

126

CO2 CAPTURE BY ABSORPTION WITH POTASSIUM CARBONATE  

Energy Technology Data Exchange (ETDEWEB)

The objective of this work is to improve the process for CO{sub 2} capture by alkanolamine absorption/stripping by developing an alternative solvent, aqueous K{sub 2}CO{sub 3} promoted by piperazine. Progress has been made in this reporting period on three subtasks. A simple thermodynamic model has been developed to represent the CO{sub 2} vapor pressure and speciation of the new solvent. A rate model has been formulated to predict the CO{sub 2} flux with these solutions under absorber conditions. A process and instrumentation diagram and process flow diagram have been prepared for modifications of the existing pilot plant system.

2002-10-01

127

Pressure Probe Technique for Measuring Water Relations of Cells in Higher Plants 1  

UK PubMed Central (United Kingdom)

A new method is described for continuously measuring cell turgor pressure (P), hydraulic conductivity (Lp), and volumetric elastic modulus (ε) in higher plant cells, using a pressure...Full Text Available

1978-02-01

128

Lesson 5: How Can You  

Wastenet

Pumped storage plants 20 are a relatively common type.They use a dam to create an upper reservoir ...Some pumped storage plants use the same water turbine and electric generator for both operating periods.That is,

129

Lesson 5: How Can You  

Wastenet

Pumped storage plants are a relatively common type.They use a dam to create an upper reservoir ...Some pumped storage plants use the same water turbine and electric generator for both operating periods.

130

Comparative aspects of pesticide metabolism in plants and animals.  

UK PubMed Central (United Kingdom)

Pesticide chemicals are an important component of modern agriculture. Through their use, plants and animals are exposed to pesticides directly and indirectly from transport through soil, water, and...Full Text Available

1978-12-01

131

Ammonium and Nitrate Uptake by the Floating Plant Landoltia punctata  

UK PubMed Central (United Kingdom)

Background and AimsPlants from the family Lemnaceae are widely used in ecological engineering projects to purify wastewater and eutrophic water bodies. However, the biology of nutrient...Full Text Available

2007-02-01

132

A comprehensive approach to cooling tower design  

Energy Technology Data Exchange (ETDEWEB)

In this paper, a mathematical model for a counterflow wet cooling tower is derived, which is based on one-dimensional heat and mass balance equations using the measured heat transfer coefficient. The balance equations are solved numerically to predict the temperature change of air and water, as well as the humidity as a function of the cooling tower high. Experimental measurements on two pilot-scale cooling towers were carried out in order to analyze the performance of different cooling tower filling materials. Also, the performance of other cooling tower elements, such as droplet separators and water spray nozzles, was investigated in the pilot experiments. The flow distribution, i.e. the velocity field, upstream to the filling material was predicted using the three-dimensional version of the computational fluid dynamics (CFD) code Fluent/UNS, version 4.2. The calculated flow fields are presented for ...

2001-06-01

133

The Polish Nuclear Society on the energy situation in Poland  

Energy Technology Data Exchange (ETDEWEB)

Discusses the resolution of the 2. Congress of the Polish Nuclear Society on the energy situation in Poland and recommendations for energy policy. Recommendations for use of nuclear power plants in Poland are made considering environmental pollution from coal combustion (air pollution by sulfur dioxide, nitrogen oxides and carbon dioxide as well as water pollution by salt from mine water discharged to rivers), development of the Polish economy, forecast increase in energy consumption and the role of nuclear energy in other European countries. Research on nuclear power plants, safety and environmental aspects as well as comparative efficiency of coal-fired power plants and nuclear power plants is evaluated.

1993-10-01

135

H. R. 4255: This Act may be cited as the Wetlands Reform Act of 1992, introduced in the US House of Representatives, One Hundred Second Congress, Second Session, February 19, 1992  

Energy Technology Data Exchange (ETDEWEB)

This bill was introduced into the US House of Representatives on February 19, 1992 to amend the Federal Water Pollution Control Act for the protection of wetlands. One of the key elements of the bill revolves around the expansion of scope and clarification of the permit program and its effects on wetlands. Additional sections address the following: exemptions for agriculture and other activities; rulemaking on prior converted wetlands; citizen suits amendments; improvement of administration of wetlands permitting; study of wetlands delineation; and wetlands restoration pilot program.

1992-01-01

136

Case studies of hazardous-waste treatment to remove volatile organics. Volume 2  

Energy Technology Data Exchange (ETDEWEB)

Case studies are presented for treatment of refinery wastes in a pilot-scale thin-film evaporator, the removal of volatiles from industrial wastewater for two steam strippers, and the removal of semivolatiles from water by steam stripping followed by liquid-phase carbon adsorption. The report provides data on removal efficiency, air emissions, process residuals, treatment costs, and process limitations. Details on sampling and analytical procedures, quality assurance, and process data are contained in the Appendixes (Volume II).

1987-11-01

137

Case studies of hazardous-waste treatment to remove volatile organics. Volume 1  

Energy Technology Data Exchange (ETDEWEB)

Case studies are presented for treatment of refinery wastes in a pilot-scale thin-film evaporator, the removal of volatiles from industrial wastewater for two steam strippers, and the removal of semivolatiles from water by steam stripping followed by liquid-phase carbon adsorption. The report provides data on removal efficiency, air emissions, process residuals, treatment costs, and process limitations. Details on sampling and analytical procedures, quality assurance, and process data are contained in the Appendixes (Volume II).

1987-11-01

138

Winter study of power plant effects  

Energy Technology Data Exchange (ETDEWEB)

As a part of DOE's Meteorological Effects of Thermal Energy Releases (METER) program a field study was undertaken at the Bowen Electric Generating Plant (Plant Bowen) in December 1979. The study was a joint endeavor of Battelle Pacific Northwest Laboratories (PNL), Pennsylvania State University (PSU), and Oak Ridge National Laboratory (ORNL) with the main objective of determining the effects of the plant's smokestack effluents on aerosol characteristics and precipitation chemistry. Other objectives included studies of cooling tower temperature and humidity (T/h) plumes and drift drop concentrations. Conducted over a period of three weeks, the study involved an instrumented aircraft, pilot balloons, a tethered balloon system, a dense network of wetfall chemistry collectors and numerous ground- and tower-based meteorological instruments. Rainfall samples collected during the ...

1980-10-01

139

Evaluation of new corrosion-resistant superheater tubing in high-efficiency waste-to-energy plants  

Energy Technology Data Exchange (ETDEWEB)

Field corrosion tests were conducted on eight single tube materials and two welded overlay materials in three typical Japanese waste incineration plants in an effort to develop new corrosion-resistant superheater tubes capable of functioning efficiently under temperature and pressure conditions of 500 C and 100 kgf/cm{sup 2}-g in high-efficiency waste-to-energy (WTE) plants. Austenitic alloys containing higher concentrations of chromium, nickel, and molybdenum [Cr + Ni + Mo] showed excellent corrosion-resistant properties, and the new alloys JHN24 and HR30M showed good corrosion resistance. Different corrosion rates found in each of the three plants were explained by differences in operating conditions, such as gas temperature, concentration of molten salts resulting from chlorine (Cl) content of deposits, heavy metal (zinc oxide [ZnO] + lead oxide [PbO]) content, etc. It was confirmed that the corrosion rate of materials ...

1998-07-01

140

On-farm water management in saline groundwater area under scarce canal water supply condition in the Northwest India  

British Library Electronic Table of Contents (United Kingdom)

The study investigates the possibility of enhancing crop water productivity in the parts of Northwest India where groundwater quality is marginal and canal water supply is severely scarce. Soil, Water, Atmosphere and Plant (SWAP) model was calibrated and validated in three farmers' fields with varying canal water availability and groundwater quality in the Kaithal Irrigation Circle of the Bhakra Canal system, Haryana. On the basis of predicted and observed soil water content, pressure heads, salt concentration at 2 week intervals and crop yields, the model was found suitable for use in the region. A few nomographs were prepared to provide a graphical method to predict the effect of different combinations of water quality and depth of water application on crop yield and soil salinity and to...

2008-01-01

141

Power-cycle studies for a geothermal electric plant for MX operating bases  

Energy Technology Data Exchange (ETDEWEB)

Binary geothermal plants were investigated for providing electrical power for MX missile bases. A number of pure hydrocarbons and hydrocarbon mixtures were evaluated as working fluids for geothermal resource temperatures of 365, 400, and 450/sup 0/F. Cycle thermodynamic analyses were conducted for pure geothermal plants and for two types of coal-geothermal hybrid plants. Cycle performance results were presented as net geofluid effectiveness (net plant output in watts per geofluid flow in 1 bm/hr) and cooling water makeup effectiveness (net plant output in watts per makeup water flow in 1 bm/hr). A working fluid containing 90% (mass) isobutane/10% hexane was selected, and plant statepoints and energy balances were determined for 20MW(e) geothermal plants at each of the three resource temperatures. ...

1981-11-01

142

Progress on the investigation of coal-water slurry fuel combustion in a medium-speed diesel engine; Part 6: In-cylinder combustion photography studies  

Energy Technology Data Exchange (ETDEWEB)

In the GE 7FDL single cylinder research diesel engine, in-cylinder high-speed photographic studies were conducted on coal-water slurry (CWS) fuel combustion. Distinct flames of pilot and CWS combustion were noticed. It was proven that the coal fuel burns after piston impingement and secondary atomization. Agglomerated particles will develop when combustion conditions are not favorable. Cylinder pressure data were simultaneously recorded for each film frame. Heat release data can thus be produced for each photo study. Most of the findings of earlier combustion studies on engine performance were confirmed.

1993-10-01

143

Assessing vineyard water status using the reflectance based Water Index  

British Library Electronic Table of Contents (United Kingdom)

In the Mediterranean arc, vines for wine production are mainly grown without the support of irrigation. Under such conditions, site variables affecting the extent and seasonal timing of water deficits are the dominant environmental constraints for grape production. Moreover, water availability and vine water status are the factors most comprehensively determining fruit composition and, thus, wine quality. Therefore, monitoring the extent of water stress in vines might be a valuable tool for the optimisation of grape yield and quality. The objective of this study was to evaluate the feasibility of using the reflectance based Water Index (WI) to estimate vine water status at the leaf and canopy levels. The study was conducted on Vitis vinifera cv. Chardonnay potted plants submitted to contra...

2010-01-01

144

The application of MOX fuel in light water nuclear power plant  

International Nuclear Information System (INIS)

MOX fuel has been one of the mature nuclear fuels which can be used in light water nuclear power plant now. The development status in this domain in foreign countries, the major influence of MOX fuel on reactor performance and the countermeasures are introduced in this paper. The application of MOX fuel in China's PWR is discussed in the end. (authors)

2008-12-01

145

International water power and dam construction yearbook 1996  

Energy Technology Data Exchange (ETDEWEB)

This document draws together data on hydroelectric power generation and dam construction for 1996. Machinery such as turbines and hydroelectric generators are listed together with their manufacturers. Contact addresses for international organizations concerned with water power are listed. Listings are also given for hydro resources worldwide, and the global distribution of pumped-storage plants, dams and hydroelectric plants. Company data is also listed providing a buyer`s guide for 1996. (UK)

1996-12-31

146

Integrating Phytoextraction and Biofortification: Fungal Accumulation of Selenium in Plant Materials from Phytoremediation of Agricultural Drainage  

Science.gov (United States)

The phytomanagement of Se-polluted soil and water is one strategy that may be environmentally sustainable and cost-effective for soils and waters enriched with natural-occurring Se. Several plant species, including Indian mustard (Brassica juncea), pickleweed (Salicornia bigelovii), and other salt/S...

147

Design basis for protection of light water nuclear power plants against effects of postulated pipe rupture  

Energy Technology Data Exchange (ETDEWEB)

This standard addresses the design bases for light water reactor, nuclear power plant structures and components essential for the protection of public health and safety from the potential adverse effects of pipe whip, jet impingement, pressurization of compartments outside containment, environmental conditions and flooding associated with a postulated pipe rupture. The design bases for missile protection and the design bases for containment pressurization are not within this standard.

1981-01-01

148

American National Standard: design basis for protection of light water nuclear power plants against effects of postulated pipe rupture  

Energy Technology Data Exchange (ETDEWEB)

This standard addresses the design bases for light water reactor, nuclear power plant structures and components essential for the protection of public health and safety from the potential adverse effects of pipe whip, jet impingement, pressurization of compartments outside containment, environmental conditions and flooding associated with a postulated pipe rupture. The design bases for missile protection and the design bases for containment pressurization are not within this standard.

1980-12-31

149

Evaluation of a permeable reactive barrier technology for use at Rocky Flats Environmental Technology Site (RFETS)  

Energy Technology Data Exchange (ETDEWEB)

Three reactive materials were evaluated at laboratory scale to identify the optimum treatment reagent for use in a Permeable Reactive Barrier Treatment System at Rocky Flats Environmental Technology Site (RFETS). The contaminants of concern (COCS) are uranium, TCE, PCE, carbon tetrachloride, americium, and vinyl chloride. The three reactive media evaluated included high carbon steel iron filings, an iron-silica alloy in the form of a foam aggregate, and a peculiar humic acid based sorbent (Humasorb from Arctech) mixed with sand. Each material was tested in the laboratory at column scale using simulated site water. All three materials showed promise for the 903 Mound Site however, the iron filings were determined to be the least expensive media. In order to validate the laboratory results, the iron filings were further tested at a pilot scale (field columns) using actual site water. Pilot test results ...

2000-01-01

150

Plan for addressing issues relating to oil shale plant siting  

Energy Technology Data Exchange (ETDEWEB)

The Western Research Institute plan for addressing oil shale plant siting methodology calls for identifying the available resources such as oil shale, water, topography and transportation, and human resources. Restrictions on development are addressed: land ownership, land use, water rights, environment, socioeconomics, culture, health and safety, and other institutional restrictions. Descriptions of the technologies for development of oil shale resources are included. The impacts of oil shale development on the environment, socioeconomic structure, water availability, and other conditions are discussed. Finally, the Western Research Institute plan proposes to integrate these topics to develop a flow chart for oil shale plant siting. Western Research Institute has (1) identified relative topics for shale oil plant siting, (2) surveyed both published and ...

1987-09-01

151

Road maps on research and development plans for water chemistry of nuclear power systems  

International Nuclear Information System (INIS)

Water chemistry of nuclear power plants has played an important role in reduction of personnel doses, structural materials and fuel integrity assurance, and reduction of radioactive wastes production. Further contributions are requested for advanced utilization of the LWR, advanced fuels and aging management of plants. Since water chemistry has an effect on all structure and materials immersed and at the same time affected by them, the optimum control not sticking to specific issues and covering the whole plant is required for these requests. Taking account of roles and activities of the industry, governmental institutes and academia, road maps on research and development plans for water chemistry were compiled into identified eleven items with targets and counter measures taken, such as common basic technologies, dose reduction, SCC mitigation, fuel cans ...

2008-05-01

152

Catalytic hydrothermal gasification of biomass for the production of synthetic natural gas[Dissertation 17100  

Energy Technology Data Exchange (ETDEWEB)

Energy from biomass is a CO{sub 2} neutral, sustainable form of energy. Anaerobic digestion is an established technology for converting biomass to biogas, which contains around 60% methane, besides CO{sub 2} and various contaminants. Most types of biomass contain material that cannot be digested; in woody biomass, this portion is particularly high. Therefore, conventional anaerobic digestion is not suited for the production of biogas from woody biomass. While wood is already being converted to energy by conventional thermal methods (gasification with subsequent methanation), dung, manure, and sewage sludge represent types of biomass whose energy potential remains largely untapped (present energetic use of manure in Switzerland: 0.4%). Conventional gas phase processes suffer from a low efficiency due to the high water content of the feed (enthalpy of vaporization). An alternative technology is the hydrothermal gasification: the water contained ...

2007-07-01

153

Progress on the investigation of coal water slurry fuel combustion in a medium speed diesel engine: Part 2. Preliminary full load test  

Energy Technology Data Exchange (ETDEWEB)

Full load (186 kW/cyl) operation using CWS fuel at 1050 rpm has been achieved on single cylinder GE-7FDL test engine. No major changes in engine parameters were made. With normal inlet air conditions, 3-5% pilot deisel fuel, separately injected or stratified into the main coal charge, was used. Inlet air temperature had to be raised about 40/sup 0/C if no pilot diesel fuel was used. The coal burnout was about 95% and the cycle efficiency was comparable to using diesel fuel. The NO/sub x/ and CO emissions were about 1/2 of those obtained normally with deisel fuel. The maximum heat release rate was higher than diesel fuel operation which resulted in higher maximum cylinder firing pressure. The combustion characteristic and its dependence on some fuel characteristics and inlet air parameters are discussed. Increasing coal burnout while limiting maximum cylinder firing pressure is the main objective of near future studies.

1988-01-01

154

Hydrogen combustion and exhaust emissions in a supercharged gas engine ignited with micro pilot diesel fuel  

International Nuclear Information System (INIS)

A hydrogen combustion and exhaust emissions in a supercharged gas engine ignited with micro pilot diesel fuel was discussed in this presentation. A schematic diagram of the experimental study was first presented. The single cylinder, water-cooled, supercharged test engine was illustrated. Results were presented for the following: fuel energy and energy share (hydrogen and diesel fuel); pressure history and rate of heat release; engine performance and exhaust emissions; effect of nitrogen dilution on heat value per cycle; effect of N_2 dilution on pressure history and rate of heat release; and engine performance and exhaust emissions. This presentation demonstrated that smooth and knock-free engine operation results from the use of hydrogen in a supercharged dual-fuel engine for leaner fuel-air equivalence ratios maintaining high thermal efficiency. It was possible to attain mor3 than 90 per cent hydrogen-energy substitution to the diesel fuel ...

2009-09-20

155

Emission characterization of an alcohol/diesel-pilot fueled compression-ignition engine and its heavy-duty diesel counterpart. Final report, August 1980-August 1981  

Energy Technology Data Exchange (ETDEWEB)

This report describes results from emissions testing of a prototype diesel engine, developed by Volvo Truck Corporation of Sweden, which uses pilot injection of diesel fuel for compression ignition of alcohol fuel injection for main combustion. In addition to this dual-fuel engine, emission testing was also conducted on a heavy-duty diesel engine of similar design. Both engines were tested over the 1979 13-mode FTP, or shorter versions of this modal test, and over the 1984 Transient FTP as well as an experimental bus cycle. The dual-fuel engine was characterized with methanol, ethanol and ethanol with 30 percent water (wt %). An oxidation catalyst was also used with methanol and ethanol. Emission characterization included regulated emissions (HC, CO, and NOX) along with total particulate, unburned alcohols, individual hydrocarbons, aldehydes, phenols, and odor. The particulate matter was characterized in terms of particle size distribution, ...

1981-08-01

156

Preliminary assessment of the modular block power plant concept  

Energy Technology Data Exchange (ETDEWEB)

Adding capacity to coal-fired plants in small increments of an overall integrated program may be the solution to the 10-year lead time required for the construction of a new plant. A preliminary study evaluates the technical and economic feasibility of a modular natural gas and coal-fired combined-cycle power plant which can be installed in three distinct phases. The plant sizes are suitable for large industrial and utility applications. The Modular Block Power Plant (MBPP) concept offers the advantages of phase construction, lower capital cost, lower cost electricity, lower air emissions, lower water requirements, and reduced solid waste discharge. Other advantages include part load availability, reduced coal inventory requirements, and easier plant siting. 11 figures, 4 tables.

1984-01-01

157

Polysomaty analysis in diploid and tetraploid Portulaca grandiflora.  

Science.gov (United States)

Polysomaty analysis of the succulent portulaca (Portulaca grandiflora Hook.) plant was carried out using flow cytometry. For both diploid and tetraploid plants, mature leaf tissue was found to have a higher level of polysomaty than young leaf tissue. Mesophyll (MP), bundle sheath (BSP) and water storage protoplasts (WSP) were isolated from leaf tissues of diploid portulaca plants. WSP had a higher degree of endopolyploidization than MP and BSP. The ploidy distribution was also variable in different floral organs. Tetraploid plants artificially induced by colchicine treatment showed a decline in the degree of polysomaty compared to diploid plants. Tetraploid plants had more spherical leaves, a larger number of petals and lower pollen fertility than diploid plants. PMID:10936528

2000-07-28

158

Experimental verification of an empirical equation for transpired tritium from plant leaves at Tarapur  

International Nuclear Information System (INIS)

The tritium in transpired water of plant leaves from four locations within site area (2=0.92) with that of measured values indicating that at Tarapur, the contribution to TFWT of plant is only from air activity and pick up through soil route is negligible during the period of study. (author)

2010-05-13

159

Use of the River Saale cascade in terms of energy supply and water control. Energetische und wasserwirtchaftliche Nutzung der Saale-Kaskade  

Energy Technology Data Exchange (ETDEWEB)

The river Saale cascade consists of seven reservoirs with a total capacity of approx. 415 Mio. m[sup 3]. The entire reservoir system covers a catchment area of 1665 km[sup 2]. The water management tasks extend to the following main fields: flood protection upkeep of minimum water stock, salt load control and power generation. The energy supply capacity of the cascade is mainly used by pumped storage plants. The last of these plants, Hohenwarte II, was put into service in 1963. (orig.)

1993-01-01

160

Production of ultra high strength steels by turbulent water cooling equipment (TWICE); Production d'aciers haute resistance par un dispositif de refroidissement a turbulence controlee  

Energy Technology Data Exchange (ETDEWEB)

A new industrial process allowing to reach very high cooling rates in the cooling section after soaking of a continuous annealing line for steel sheets is presented. This process constitutes the successful conclusion of a long term research programme, jointly carried out at CRM and Arcelor Cockerill-Sambre for three years, including laboratory experiments, pilot scale trials and several industrial campaigns. It is running on from developments performed in the framework of the HOWAQ (Hot Water Quench) process. The process successively combines a moderate cooling step (600 deg C/s for 0.8 mm thick strips), in boiling water, and a faster cooling step (above 700 deg C/s), by impinging turbulent cold water in a box. Its main features are simplicity, resulting from advanced developments, soundness, flexibility and cooling homogeneity. As treated steel products are characterized by improved mechanical ...

2003-08-01

161

Measurement of snow water storage in the Lake Saperior basin using aerial gamma-ray spectrometry  

International Nuclear Information System (INIS)

A pilot project was started in 1977 over the Lake Superior basin to measure water storage on the land area using aerial gamma-ray spectrometry to provide hydrologic information for forecasting inflow to the lake. Two airborne surveys were made, respectively in November 1977 and March 1978 which provided estimates of the increase in snow water equivalent between these surveys. The basin is located on the Canadian Shield and consequently, the gamma radiation count rate is quite variable. The airborne results are compared with ground measurements on selected flight lines and show generally good agreement. Two equipment calibrations in the Ottawa area provided inconsistent parameter values which are consequently also reflected in the results over the Lake Superior basin. The project has demonstrated to-date that the technique can be developed into an operational system for measuring snow cover water ...

1977-11-01

162

Safety designs for sludge ducts in brown coal briquetting plants  

Energy Technology Data Exchange (ETDEWEB)

Studies technological safety of installing a water spray pressure vessel between electrostatic dedusters and coal sludge ducts. These sprays are in use elsewhere for steam generator ash removal. Dust ignition and explosion tests were carried out to examine flame and pressure wave propagation through the vessel into ducts. Water jet diameter, amount of water sprayed and coal dust removed were varied. Pressure waves exceeded 250 Pa. Test results show the vessel to be suitable for installation in briquetting plants due to its flame and explosion barrier effect and extermination of smoldering dust fires. The only disadvantage of the vessel is seen as its water and electric power consumption; about 8/sup 3//h of water and 1.5 kW/h of power per vessel serving dedusters of a 2,200 m/sup 2/ rotary brown coal dryer.

1987-06-01

163

Heavy water leak due to fretting of DN tube  

International Nuclear Information System (INIS)

Wolsung nuclear power plant has experienced four occasions of reactor shutdown owing to heavy water leaks since its commercial operation. Among these heavy water leaks, only one case was acute and brought about reactor shutdown but the other cases listed below were chronic and repaired after manual reactor shutdown. (author). 4 tabs., 10 figs.

1989-06-04

164

Basis for Interim Operation (BIO) for the Rework Unit (RW), Du Pont Water (DW) Plant, Moderator Processing Facility (MPF), and Technical Purification Facility (TPF)  

Energy Technology Data Exchange (ETDEWEB)

The mission of the Heavy Water portion of D Area (or 400 Area) at SRS is to purify the site inventory of heavy water for storage in the Reactor Areas for future DOE missions.

1996-01-01

165

Predicting urban forest growth and its impact on residential landscape water demand in a semiarid urban environment  

British Library Electronic Table of Contents (United Kingdom)

We present an innovative approach to estimating residential irrigation water demand for a large metropolitan area using GIS data, weather station data, and a water budget modeling approach commonly used by plant scientists and landscape management professionals. An important question addressed by our study is how a growing urban forest affects the overall irrigation water demand of a semiarid metropolitan area. To estimate the amount of water required by residential landscaping, we consider water demand to be a function of the areal extent of residential landscaping (i.e. tree/shrub or turf grass), the water-loss rate for different landscaping types, the efficiency with which the landscape is irrigated, and local climatic factors (i.e. reference evapotranspiration and precipitation). We es...

2011-01-01

166

Preliminary study of the effect of pumped-storage plant operation on zooplankton  

Energy Technology Data Exchange (ETDEWEB)

The hydromechanical effect of hydroelectric stations on zooplankton is customarily regarded as a constantly acting and comparatively harmless factor, since its destruction is inevitable when water masses are passed through hydroelectric stations, but its capacity for restoration is high (i.e., destruction of the zooplankton of the forebay is compensated by its production in the after bay). It is not known how correct such an opinion is, or what is the true balance of losses and reproduction of zooplankton in the forebays and after bays of hydroelectric stations. However, hydroelectric plants of a new type, pumped-storage plants, have been constructed in recent years and others are planned for the Dnieper reservoirs. The operational principle and purpose of these plants is that they employ special vertical turbine-electric pumps that pump water at night from the reservoirs into ...

1980-01-01

167

Applications of cathodic protection for the protection of aqueous and soil corrosion of power plant components  

International Nuclear Information System (INIS)

Power plant components exposed to environments such as water and soil are susceptible to severe corrosion. Many times the effect of corrosion in power plant components can be catastrophic. The problem is aggravated for underground pipelines due to additional factors such as large network of pipelines, proximity to earth mat, high voltage transmission lines, corrosive chemicals, inadequate approach etc. Other components such as condenser water boxes, internals of pipelines, clarifier bridge structures, cooling water inlet gates and pipes etc. which are in continuous contact with water, are subjected to severe corrosion. The nature and locations of all such components are at places which are not accessible for routine maintenance and hence they require long term reliable protection against corrosion. Experience has shown that anti-corrosive coatings are inadequate ...

1999-11-22

168

Influence of fly ash on soil physical properties and turfgrass establishment  

Energy Technology Data Exchange (ETDEWEB)

A field study (1993-96) assessed the benefits of applying unusually high rates of coal fly ash from power plants as a soil amendment to enhance water retention of soils without adversely affecting growth and marketability of the turf species, centipedegrass (Eremochloa ophiuroides (Munro) Hack.) A Latin Square plot design was employed that included 0 (control, no fly ash applied), 280, 560 and 1120 MgHa {sup -1} application rates of unweathered precipitator fly ash. The fly ash was spread evenly over each plot area, rototilled, and allowed to weather under natural conditions for 8 months before seeding. High levels of soluble salts, indicated by the electrical conductivity of soil extracts, in tandem with an apparent phytotoxic effect from boron, apparently inhibited initial plant establishment as shown by substantially lower germination counts in treated soil. However, plant height and rooting depth ...

2001-04-01

169

CO2 Capture by Absorption with Potassium Carbonate  

Energy Technology Data Exchange (ETDEWEB)

The objective of this work is to improve the process for CO{sub 2} capture by alkanolamine absorption/stripping by developing an alternative solvent, aqueous K{sub 2}CO3 promoted by piperazine (PZ). Pilot plant testing was performed in a 16.8-inch ID absorber and stripper with recirculation of air and CO{sub 2}. Three solvents (7 m MEA, 5 m K{sup +}/2.5 m PZ, and 6.4 m K{sup +}/1.6 m PZ) were tested in four campaigns with three different absorber packings. Pilot plant testing established that 5 m K{sup +}/2.5 m PZ requires two times less packing than 7 m MEA and three times less packing than 6.4 m K{sup +}/1.6 m PZ. A rigorous model of the thermodynamics and mass transfer was developed in the RateSep{trademark} block of AspenPlus{reg_sign}. The double matrix stripper reduces energy consumption by 5 to 15%. The best K{sup +}/PZ solvent, 4 m K{sup +}/4 m PZ, and the best process configuration, double ...

2007-08-31

170

Far-field model of the regional influence of effluent plumes from ocean thermal energy conversion (OTEC) plants  

Science.gov (United States)

Ocean thermal energy conversion (OTEC) plants discharge large volumes of cold water into the upper ocean. A three-dimensional, limited-area model was developed to investigate the regional influence of the far-field effluent plume created by the negatively buoyant discharge. The model was applied to discharges from a 40-MW/sub e/ OTEC plant into coastal waters characterized by various ambient ocean conditions. A typical ambient temperature structure and nutrient distribution, as well as the behavior of the effluent plume itself, were strongly modified by the discharge-induced circulation. Although temperature perturbations in the plume were small, upward entrainment of nutrients from below the thermocline was significant. The regional influence of discharges from an 80-MW/sub e/ OTEC plant, the interactions between the discharges from two adjacent 40-MW/sub e/ OTEC ...

1985-07-01

171

ENGINEERING DEVELOPMENT OF COAL-FIRED HIGH-PERFORMANCE POWER SYSTEMS  

Energy Technology Data Exchange (ETDEWEB)

A High Performance Power System (HIPPS) is being developed. This system is a coal-fired, combined cycle plant with indirect heating of gas turbine air. Foster Wheeler Development Corporation and a team consisting of Foster Wheeler Energy Corporation, Bechtel Corporation, University of Tennessee Space Institute and Westinghouse Electric Corporation are developing this system. In Phase 1 of the project, a conceptual design of a commercial plant was developed. Technical and economic analyses indicated that the plant would meet the goals of the project which include a 47 percent efficiency (HHV) and a 10 percent lower cost of electricity than an equivalent size PC plant. The concept uses a pyrolyzation process to convert coal into fuel gas and char. The char is fired in a High Temperature Advanced Furnace (HITAF). The HITAF is a pulverized fuel-fired boiler/air heater where steam is generated and gas ...

1998-10-01

172

Recent activities of the nuclear fuel technology department of Cekmece Nuclear Research and Training Center  

Energy Technology Data Exchange (ETDEWEB)

The Nuclear Fuel Technology Department (NFTD) in CNRTC is a unique unit in Turkey in charge of performing all activities in nuclear fuel field. It has a pilot plant on uranium refining and conversion to UO{sub 2} since 1986. Presently, its R and D activities are focused on pellet manufacturing and characterization: UO{sub 2}, ThO{sub 2}and (Th,U)O{sub 2}. The studies on thorium dioxide fuel include to obtain ThO{sub 2} pellets from thorium nitrate and mixed (Th,U)O{sub 2} pellets. A study on evaluation of different fuel cycle options in accordance with nuclear energy planning in Turkey is also going on. (author)

1997-07-01

173

Radiation technology, radiation technics and technological dosimetry in the Institute of Isotopes of the Hungarian Academy of Sciences. 1966-1981  

Energy Technology Data Exchange (ETDEWEB)

Pilot-plant irradiation began in Hungary in 1969 with the construction of a high-activity multi-purpose /sup 60/Co facility. Technologies for radiation sterilization, food handling, plastics irradiation as well as chemical dosimetry, semiconductor instrumental dosimetry, computer-based construction and control methods have been developed. Our chlorobenzene dose-meter system is used in Hungary and abroad; as a result of an IAEA-organized dosimetric intercomparison the system was adopted as a reference system. The institute has developed into a basic institute for the reconstruction and re-load of old ..gamma..-facilities as well as it serves for the planning, construction and launching of new ones in Hungary.

1982-01-01

174

Nondestructive characterization of low-level transuranic waste  

Energy Technology Data Exchange (ETDEWEB)

The use of nondestructive evaluation (NDE) methods is proposed for characterization of transuranic (TRU) waste stored at the Radioactive Waste Management Complex. These NDE methods include real-time x-ray radiography, real-time neutron radiography, x-ray and neutron computed tomography, thermal imaging, container weighing, visual examination, and acoustic measurements. An integrated NDE system is proposed for characterization and certification of TRU waste destined for eventual shipment to the Waste Isolation Pilot Plant in New Mexico. Methods for automating both the classification waste and control of a complete nondestructive evaluation/nondestructive assay system are presented. Feasibility testing of the different NDE methods, including real-time x-ray radiography, and development of automated waste classification techniques are covered as part of a five year effort designed to yield a production waste characterization system.

1981-10-01

175

Implementing 10 CFR Part 830 Subpart B at WIPP  

Energy Technology Data Exchange (ETDEWEB)

Implementation of Title 10 Code of Federal Regulations Part 830, Subpart B Nuclear Safety Management (1) was accomplished at the Waste Isolation Pilot Plant (WIPP) in a timely and efficient manner. The primary reason the transition went smoothly was that the existing safety analysis was relatively new, initially developed in 1995, and written in accordance with the safe harbor document DOE-STD-3009 (2). The WIPP Safety Analysis Report (SAR) (3) is kept up-to-date with the unreviewed safety question (USQ) process and thorough oversight and input provided by DOE-Carlsbad Field Office (CBFO) documented in the annual safety evaluation report (SER) process.

2002-02-26

176

Development of fluidized bed cement sintering technology  

Energy Technology Data Exchange (ETDEWEB)

In the new system presented in this paper, the cement clinker is sintered, not in a rotary kiln, but in two different furnaces: a spouted bed kiln and a fluidized bed kiln. The heat generated in the process of cooling the cement clinker is recovered by a fluidized bed cooler and a packed bed cooler, which are more efficient than the conventional coolers. Compared with the rotary kiln system, the new technology significantly reduces NO{sub x} emissions, appreciably cuts energy consumption, and reduces CO{sub 2} emissions as well. Thus, the new system is an efficient cement sintering system that is friendly to the global environment. In this paper, we describe this new technology as one of the applied technologies at an industrial level that is being developed in the Clean Coal Technology Project, and we present the results from test operations at our pilot plant.

1994-12-31

177

Coolside Waste Management Research quarterly technical progress report, January 1, 1993--March 31, 1993  

Energy Technology Data Exchange (ETDEWEB)

This project seeks to produce sufficient information on the physical and chemical nature of Coolside waste to design and construct physically stable and environmentally safe landfills. Unconfined compressive strength and permeability tests are reported on samples remolded near 90, 95, and 100% of low energy, standard, and modified dry densities. Unconfined compressive strength tests were also performed on some of the samples after permeability tests were completed. Swell tests were initiated on samples from Coolside pilot plant run {number_sign}2 and on a FBC hydrated ash remolded near 95% of standard density and optimum moisture content.

1993-11-01

178

CO{sub 2} CAPTURE BY ABSORPTION WITH POTASSIUM CARBONATE  

Energy Technology Data Exchange (ETDEWEB)

The objective of this work is to improve the process for CO{sub 2} capture by alkanolamine absorption/stripping by developing an alternative solvent, aqueous K{sub 2}CO{sub 3} promoted by piperazine. Thermodynamic modeling predicts that the heat of desorption of CO{sub 2} from 5m K+/2.5 PZ from 85 kJ/mole at 40 C to 30 kJ/mole at 120 C. Mass transfer modeling of this solvent suggests that carbonate and general salt concentration play a major role in catalyzing the rate of reaction of CO{sub 2} with piperazine. Stripper modeling suggests that with the multipressure stripper, the energy consumption with a generic solvent decreases by 15% as the heat of desorption is decreased from 23.8 to 18.5 kcal/gmol. A second pilot plant campaign with 5m K+/2.5 PZ was successfully completed.

2005-01-31

179

CO2 CAPTURE BY ABSORPTION WITH POTASSIUM CARBONATE  

Energy Technology Data Exchange (ETDEWEB)

The objective of this work is to improve the process for CO{sub 2} capture by alkanolamine absorption/stripping by developing an alternative solvent, aqueous K{sub 2}CO{sub 3} promoted by piperazine. Stripper modeling suggests the energy requirement with a simple stripper will be about the same for 5 m K{sup +}/2.5 m PZ and 7 m MEA. Modeling with a generic solvent shows that the optimum heat of CO{sub 2} desorption to minimize heat duty lies between 15 and 25 kcal/gmol. On-line pH and density measurements are effective indicators of loading and total alkalinity for the K+/PZ solvent. The baseline pilot plant campaign with 30% MEA has been started.

2005-04-29

180

CO2 CAPTURE BY ABSORPTION WITH POTASSIUM CARBONATE  

Energy Technology Data Exchange (ETDEWEB)

The objective of this work is to improve the process for CO{sub 2} capture by alkanolamine absorption/stripping by developing an alternative solvent, aqueous K{sub 2}CO{sub 3} promoted by piperazine. CO{sub 2} mass transfer rates are second order in piperazine concentration and increase with ionic strength. Modeling of stripper performance suggests that 5 m K{sup +}/2.5 m PZ will require 25 to 46% less heat than 7 m MEA. The first pilot plant campaign was completed on June 24. The CO{sub 2} penetration through the absorber with 20 feet of Flexipac{trademark} 1Y varied from 0.6 to 16% as the inlet CO{sub 2} varied from 3 to 12% CO{sub 2} and the gas rate varied from 0.5 to 3 kg/m{sup 2}-s.

2004-07-29

181

Application of probabilistic methods to accident analysis at waste management facilities  

International Nuclear Information System (INIS)

Probabilistic risk assessment is a technique used to systematically analyze complex technical systems, such as nuclear waste management facilities, in order to identify and measure their public health, environmental, and economic risks. Probabilistic techniques have been utilized at the Waste Isolation Pilot Plant (WIPP) near Carlsbad, New Mexico, to evaluate the probability of a catastrophic waste hoist accident. A probability model was developed to represent the hoisting system, and fault trees were constructed to identify potential sequences of events that could result in a hoist accident. Quantification of the fault trees using statistics compiled by the Mine Safety and Health Administration (MSHA) indicated that the annual probability of a catastrophic hoist accident at WIPP is less than one in 60 million. This result allowed classification of a catastrophic hoist accident as ''not credible'' at WIPP per DOE definition. Potential uses of ...

182

An analysis of cropland carbon sequestration estimates for North Central Monana  

British Library Electronic Table of Contents (United Kingdom)

A pilot cropland carbon sequestration program within north central Montana has allowed farmers to receive carbon credit for management adjustments associated with changing from tillage-based agricultural systems to no-till. Carbon credit can also be obtained by adopting conservation reserve, where cropland is planted into perennial vegetation. Summer fallowing is also considered within the crediting process as credit is not given in years that a field is left un-vegetated. The carbon sequestration program has been advocated as a means to mitigate climate change while providing an added source of income for Montana farmers. There is lack of data, however, pertaining to the percentage of lands within this region that have not converted to no-till management, lands under certain crop intensit...

2011-01-01

183

Advances in feedstock recycling offer help with plastic waste  

Energy Technology Data Exchange (ETDEWEB)

An idea whose time has come takes center stage in London this week when BP Chemicals announces details of a consortium of chemical companies joining it in a new recycling project. In the project, which BP has been working on since 1989, waste plastic will be depolymerized to chemical feedstocks, via technology variously called feedstock or chemical recycling, polymer cracking, or tertiary recycling. BP's effort is one of the first to emerge from the research and pilot-plant stages that are committed to actual feedstock recycling of mixed polyolefins and other plastics. But it is only one of the many industry efforts under way to cope with the job of dealing with postconsumer plastics.

1993-10-04

184

A study on the economic efficiency of hydrogen production from biomass residues in China  

Energy Technology Data Exchange (ETDEWEB)

As part of Pilot Project of KIP of CAS, a feasibility study of hydrogen production system using biomass residues is conducted. This study is based on a process of oxygen-rich air gasification of biomass in a downdraft gasifier plus CO-shift. The capacity of this system is 6.4 t biomass/d. Applying this system, it is expected that an annual production of 480 billion N m{sup 3} H{sub 2} will be generated for domestic supply in China. The capital cost of the plant used in this study is 1328/(N m{sup 3}/h) H{sub 2} out, and product supply cost is 0.15/N m{sup 3} H{sub 2}. The cost sensitivity analysis on this system tells that electricity and catalyst cost are the two most important factors to influence hydrogen production cost. (author)

2008-08-15

185

BIBRA "t"r"a"d"e"m"a"r"k - the biological treatment of radioactive waste water  

International Nuclear Information System (INIS)

BIBRA "t"r"a"d"e"m"a"r"k, is the new bio-technological method developed in Gundremmingen for treating radioactive waste water, using bacteria in a process analogous to the long-established principle of communal sewage treatment plants. The method exploits the behaviour of the micro-organisms found there, to establish optimum adaptation of their population for decomposing the typical pollutants found in this washing water. This procedure is particularly suitable for nuclear engineering plants, because in such plants the waste water composition changes little so that the bacteria can achieve optimum adaptation to this waste water. The organic ingredients of the washing media are decomposed by introducing air. The advantage of the procedure is not only the significant reduction of the amount of waste material, but also enhanced efficiency of ...

1999-03-01

186

Safety analysis and justification for modification of auxiliary feed-water system in Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

The major feed-water line break accident is re-analyzed, which is based on Guangdong Daya Bay nuclear power station final safety analysis report, to justify the impacts of the decreasing of auxiliary feed-water flow rate on the safety margin in Daya Bay. The results showed that the accident analysis can meet the demands of acceptance criteria with the auxiliary feed-water flowrate decreasing from 45 m"3/h to 41.8 m"3/h, and enough safety margin is still retained

2002-06-01

187

Biosorption process for removing heavy metal ions using water milfoil (Myriophyllum Spicatum) in contaminated water  

Energy Technology Data Exchange (ETDEWEB)

A small scale biomass metal contacting experiment was performed to screen the optimal plant species for biosorption and bioaccumulation of cadmium, zinc, nickel, lead, and copper. Experiments were also conducted to test the ability of the biomass to lower the metal concentrations below the US Environmental Protection Agency surface water discharge criteria. The minimum residual concentration was 0.1 mg/L for zinc, 0.004 mg/L for lead, and about 0.01 mg/L for cadmium, nickel, and lead. Results indicate that water milfoil can be used for bioremoval of metals.

1995-12-31

188

Using n-ZnO-Al as window layer in pilot production of CIGSSe solar modules: Status and trends. Status of CIGSSe pilot scale production at Munich; Einsatz von n-ZnO:Al als Fensterschicht in der Pilotfertigung von CIGSSe-Solarmodulen: Status and Entwicklung. Status der CIGSSe-Pilotfertigung in Muenchen  

Energy Technology Data Exchange (ETDEWEB)

Shell Solar GmbH is working on a variant of the so-called stacked elemental layer process for CIGSSe absorber production. The metal films resp. the selenium are deposited on the Mb electrode at room temperature by DC sputtering (CIG) or evaporation (Se) and then processed into semiconductors by rapid thermal annealing (RTP). Currently, the mean efficiency of the pilot plant is i 12.6 {+-} 0.2 % for non-sealed 30 x 30 cm{sup 2} modules, the key efficiency is 13.0 %. In addition to the 30 x 30 cm{sup 2} pilot line, a small series of 60x90cm2 modules was constructed in December 2004. Here, the mean efficiency was 13.0 percent while the average module power was higher than 60 W. The contribution also describes investigations of ceramically sputtered n-ZnO:Al layers with reduced Al concedntrations of 1 percent and on reactively sputtered n-ZnO.Al layers from the double roller magnetron. (orig.) [German] Bei Shell Solar GmbH wird ...

2005-07-01

189

Water induction studies in a hydrogen-diesel dual-fuel engine  

Energy Technology Data Exchange (ETDEWEB)

Power output of a hydrogen-diesel dual-fuel engine is limited by the onset of knock as the percentage of heat input derived from hydrogen increased beyond a certain limit. Earlier work carried out at the Internal Combustion Engines Laboratory, Indian Institute of Technology, Madras, indicates that this knock sets in when the induced hydrogen exceeds about 60% of input energy at a pilot diesel quantity of 30% of full load diesel amount. At higher rates of hydrogen induction, the richer hydrogen-air mixture is more prone to knocking. Hardly any information is available on the possibilities of improving the knock limited power output of a hydrogen-diesel dual-fuel engine. Water can serve as a powerful internal coolant in decreasing the unburned mixture temperature because of its high latent heat. This paper presents the results of our investigation on improving the knock limited power output when water is inducted with the ...

1987-01-01

190

Biological in situ remediation of a former pond for trickling waste water containing explosives  

Energy Technology Data Exchange (ETDEWEB)

WASAG DECON developed a concept for the biological in situ remediation of an TNT-contaminated former seepage pond. This pond is located on the site of an ammunition factory in Lower Saxony. Unit 1982 all the waste water from the production buildings was directed into this pond, including TNT-contaminated water from the flushing of shells. Due to this practice, the sediment of the pond, the underlying soil and the groundwater became contaminated with TNT. The area of the soil contamination adds to abut 2.000 m{sup 2}. The remediation concept includes three steps: 1. Excavation of the most highly contaminated soil with TNT-concentrations above 1000 mg/kg. 2. Reduction of the remaining contamination by a biological in situ treatment using organic and inorganic amendments and mechanical tillage. After about to years of treatment, remediation goals of 50 mg/kg are expected to be reached on most of the area. 3. Contaminations eventually remaining in ...

2003-07-01

191

Photosynthetic consequences of phenotypic plasticity in response to submergence: Rumex palustris as a case study  

British Library Electronic Table of Contents (United Kingdom)

Survival and growth of terrestrial plants is negatively affected by complete submergence. This is mainly the result of hampered gas exchange between plants and their environment, since gas diffusion is severely reduced in water compared with air, resulting in O2 deficits which limit aerobic respiration. The continuation of photosynthesis could probably alleviate submergence-stress in terrestrial plants, but its potential under water will be limited as the availability of CO2 is hampered. Several submerged terrestrial plant species, however, express plastic responses of the shoot which may reduce gas diffusion resistance and enhance benefits from underwater photosynthesis. In particular, the plasticity of the flooding-tolerant terrestrial species Rumex palustris turned out to be remarkable,...

2006-01-01

192

Radioactivity decontamination efficiency of ceramic filter in an incineration volume reduction system of radioactive waste  

Energy Technology Data Exchange (ETDEWEB)

The small pilot facility of a cyclone type suspension incineration system of radioactive waste was set up in order to evaluate the decontamination efficiency of a high efficiency ceramic filter. The evaluation was made by use of /sup 54/Mn, /sup 59/Fe, /sup 60/Co, /sup 65/Zn and /sup 137/Cs. 1. The decontamination factor by one line of ceramic filter for every species were over 10/sup 5/. 2. The decontamination factor increased by one oder when water vapor exists in off-gas. The same tendency was also observed when iron dioxide existed at the incineration of cation exchange resin.

1987-02-01

193

Radioactivity decontamination efficiency of ceramic filter in an incineration volume reduction system of radioactive waste  

International Nuclear Information System (INIS)

The small pilot facility of a cyclone type suspension incineration system of radioactive waste was set up in order to evaluate the decontamination efficiency of a high efficiency ceramic filter. The evaluation was made by use of "5"4Mn, "5"9Fe, "6"0Co, "6"5Zn and "1"3"7Cs. 1. The decontamination factor by one line of ceramic filter for every species were over 10"5. 2. The decontamination factor increased by one oder when water vapor exists in off-gas. The same tendency was also observed when iron dioxide existed at the incineration of cation exchange resin. (author).

194

Low temperature humidification dehumidification desalination process  

Energy Technology Data Exchange (ETDEWEB)

The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling ...

2006-03-01

195

Low temperature humidification dehumidification desalination process  

International Nuclear Information System (INIS)

The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling ...

2006-03-01

196

Non-catalytic and catalytic wet air oxidation of pharmaceuticals in ultra-pure and natural waters  

British Library Electronic Table of Contents (United Kingdom)

A wet air oxidation (WAO) process was applied to four selected pharmaceuticals (metoprolol, naproxen, amoxicillin, and phenacetin) individually dissolved in ultra-pure water, varying the temperature and oxygen pressure. Due to the moderate (amoxicillin) or low (metoprolol, naproxen, and phenacetin) efficiency found in the oxidation of these pollutants, a catalytic wet air oxidation (CWAO) process was then tested using a platinum catalyst supported on multi-walled carbon nanotubes (CNT). In this CWAO process, the pharmaceuticals were dissolved together in ultra-pure water and in four natural water matrices-a reservoir water, a groundwater, and two waters from different municipal wastewater treatment plants. On the basis of the measurements of their removals, a discussion is given of the inf...

2011-01-01

197

Use of sodium aluminate in waste water treatment plants: wishes of saving money and innovating; Uso del aluminato sodico en las EDAR: una propuesta para innovar y economizar costes de explotacion  

Energy Technology Data Exchange (ETDEWEB)

Most waste water treatment plants have processes to remove nutrients in order to avoid eutrophication in water receiving bodies. Regarding phosphorus removal. the most common option is chemical precipitation with ferric or aluminical precipitation with ferric or aluminium salts. We show here the successful experience carried out by the WWTP of Blanes and the company Safloc. A method ato remove phosphorus from waste water was developed by adding sodium aluminate. The use of this compound has turned out to be a sustainable way for this purpose in terms of costs, reliability and minimization of sludge production. (Author)

2006-07-01

198

Effect of postharvest water deficit stress on gene expression in heads of broccoli (Brassica oleracea var. italica)  

British Library Electronic Table of Contents (United Kingdom)

Harvested plant organs such as heads of broccoli (Brassica oleracea L. var. italica) experience a range of stresses that can lead to premature reduction in quality and eventual senescence. Understanding plant responses to stress may open up novel opportunities to extend postharvest life. One of the first stresses experienced by harvested organs is likely to be water deficit stress since severance of the vascular system halts the normal flux of water into the tissue. For broccoli branchlets with their cut ends held in water, transcriptome analysis based on hybridization of broccoli floret mRNA to a heterologous Arabidopsis microarray revealed that the transcript abundance of 431 genes reliably changed within 48h of harvest. Of these, transcripts of 146 genes increased and 34 genes decreased...

2011-01-01

199

Marine pastures: a by-product of large (100 megawatt or larger) floating ocean thermal power plants. Progress report, February 1, 1976--April 30, 1976  

Science.gov (United States)

Computer programs have been developed to define the temperature increase which would be needed to bring deep-ocean water into density equilibrium with surface water for locations where data are available. A series of continuous-flow studies on phytoplankton blooms resulting from mixtures of 80 percent deep and 20 percent surface water in 2000-liter concrete culturing vessels (''reactors'') has been completed. A quantitative determination of nutrient utilization and flow through a combined primary and secondary trophic level system has been completed. This study utilized the clam Tapes semidecussata, fed from phytoplankton grown in 80 percent deep and 20 percent surface water. An analysis of the fate of the deep water discharged from a floating OTEC plant indicates that horizontal containment of the resulting deep ...

1976-01-01

200

Quality assurance requirements for installation, inspection, and testing of mechanical equipment and systems  

International Nuclear Information System (INIS)

The guide describes a method acceptable to the NRC staff for complying with the Commission's regulations with regard to quality assurance requirements for installation, inspection, and testing of mechanical equipment and systems for water-cooled and high-temperature gas-cooled nuclear power plants.

201

Osmotically Induced Removal of Water from Fungal Cells as Determined by a Spin Probe Technique 1  

UK PubMed Central (United Kingdom)

Effects of physical environment on plasma membrane semipermeability and osmotic induction of changes in aqueous cytoplasmic volume were studied in vegetative and spore cells of a plant pathogenic fungus,...Full Text Available

1978-11-01

202

Occurrence of fecal indicator bacteria in surface waters and the subsurface aquifer in Key Largo, Florida.  

UK PubMed Central (United Kingdom)

Sewage waste disposal facilities in the Florida Keys include septic tanks and individual package plants in place of municipal collection facilities in most locations. In Key Largo, both facilities discharge...Full Text Available

1995-06-01

203

Final Report of ''On-the-Job Training'' on the CANDU Reactor.  

Science.gov (United States)

This is the final Report for the technical ''on-the-job traning'' for the Wolsung CANDU nuclear power plant which is the first Pressurized Heavy Water Reactor setting up in Korea. The technical ''on-the-job traning'' was established to increase the capabi...

1983-01-01

204

Evaluation of field application of boric acid  

International Nuclear Information System (INIS)

Results of field applications of boric acid in the secondary coolant circuits of seven PWR units for the purpose of reducing the rate of corrosion denting are reported. Based on available data at the power plants considered in this study, it was not possible to support or refute the benefit of using boric acid secondary water treatment.

1985-03-01

205

Development of Tritium Removal Technology.  

Science.gov (United States)

Liquid Phase Catalytic Exchange (LPCE)- Cryogenic Distillation(CD) process was studied which could be available for an optimal tritium removal process of pressurized heavy water reactor system at Wolsung nuclear power plant in the near future. Based upon ...

1986-01-01

206

Atomic Energy of Canada Limited-Chemical Company Annual Review of Operations, 1980-81.  

Science.gov (United States)

Record production of heavy water was achieved: the plants at Glace Bay and Port Hawkesbury, Nova Scotia, produced a total of 560 megagrams. A shipment of 500 Mg was delivered on time to the Wolsung CANDU reactor in Korea. Energy conservation and waste hea...

1981-01-01

207

Application of ribotyping for differentiating aeromonads isolated from clinical and environmental sources.  

UK PubMed Central (United Kingdom)

We have investigated the usefulness of ribotyping for the differentiation of aeromonads isolated from five patients with gastroenteritis and from the source water, treatment plant, and distribution...Full Text Available

1992-06-01

208

Integral severe accident analysis of light water nuclear power plants by IMPACT-SAMPSON code  

Energy Technology Data Exchange (ETDEWEB)

The NUclear Power Engineering Corporation (NUPEC) has developed IMPACT-SAMPSON code to analyze integral behavior of light water nuclear power plants under severe accident conditions. IMPACT-SAMPSON's distinguishing features include interconnected hierarchical modules and mechanistic models covering a wide spectrum of scenarios ranging from normal operation to severe accident events, and high-speed simulation on parallel processing computers. The integral plant behaviors of typical PWR and BWR under severe accident conditions have been analyzed with the IMPACT-SAMPSON code. The PWR plant analyzed was the three-loop, steel-dry containment type with 2,440 MWt. The AE accident scenario was supposed, that is, LOCA by 6-inch hot leg failure followed by accumulated water injection, but no ECCS and containment spray activation. The BWR plant analyzed was the ...

2003-07-01

209

Handling of water-endangering substances and model operating instructions for hydropower plants; Umgang mit wassergefaehrdenden Stoffen und Musterbetriebsanweisung fuer Wasserkraftwerke  

Energy Technology Data Exchange (ETDEWEB)

The adaption of the Muster-VAwS (model ordinance on the handling of water endangering substances in plants and specialized facilities) in the ordinances of the different German states, means that the legislator has laid down concrete - technical and organizational - requirements concerning the handling of water-endangering substances for all plants. The present example of the systematic stocktaking of all environmentally relevant substances in the context of the operation of the pumped storage plants of Schluchseewerk AG, Freiburg, an the application of the model operating instructions for hydropower plants shall serve to illustrate two important aspects for the implementation of this extensive ordinance. (orig.) [Deutsch] Durch Umsetzung der Muster-VAwS (Muster-Verordnung ueber Anlagen zum Umgang mit wassergefaehrdenden Stoffen und Fachbetriebe) in ...

1998-08-01

210

Treatment of Produced Waters Using a Surfactant Modified Zeolite/Vapor Phase Bioreactor System  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes work performed on this project from October 2004 through March 2005. In previous work, a surfactant modified zeolite (SMZ) was shown to be an effective system for removing BTEX contaminants from produced water. Additional work on this project demonstrated that a compost-based biofilter could biodegrade the BTEX contaminants found in the SMZ regeneration waste gas stream. However, it was also determined that the BTEX concentrations in the waste gas stream varied significantly during the regeneration period and the initial BTEX concentrations were too high for the biofilter to handle effectively. A series of experiments were conducted to determine the feasibility of using a passive adsorption column placed upstream of the biofilter to attenuate the peak gas-phase VOC concentrations delivered to the biofilter during the SMZ regeneration process. In preparation for the field test of the SMZ/VPB treatment system in New Mexico, a ...

2005-03-11

211

Studies on the CRUD Deposition on Fuel Cladding Surface Using AOA Water Chemistry Loop  

International Nuclear Information System (INIS)

Axial offset anomaly (AOA) is caused by the deposition of crud on the fuel cladding of a PWR. When significant levels of crud build up on the cladding, boron can accumulate in the pores of the crud as a concentrated solution or solid phase, and cause the flux depression. Numerous studies have been conducted on the primary water chemistry to reduce the amount of crud in the primary circuit to avoid radioactivity buildup and unexpected power transition in the plant. However, experiments on the crud are restricted in the laboratory because the crud is a highly radioactive material. The objective of this study is to develop a test method for simulating the deposition of crud in a nuclear power plant

2010-10-01

212

Shell coal gasification plant (SCGP-1) environmental performance results  

Energy Technology Data Exchange (ETDEWEB)

Environmental studies in slip-stream process development units at SCGP-1, Shell's advanced coal gasification demonstration plant, located near Houston, Texas, have demonstrated that the gas and water effluents from the Shell Coal Gasification Process (SCGP) are environmentally benign on a broad slate of coals. This report presents the results of those environmental studies. It contains two major subjects, which describe, respectively, the experiments on gas treating and the experiments on water treating. Gas treatment focused on the performance of aqueous methyldiethanolamine (MDEA) and sulfinol-M. 8 refs., 24 figs., 13 tabs.

1991-07-01

213

A horizontal steam generator for the Indian 235 MW heavy water nuclear power plants  

International Nuclear Information System (INIS)

In this paper the thermal design of a horizontal steam generator for the Indian PHWR nuclear power plant is described. The main attraction is absence of tube sheet and use of stainless steel 'U' tubes. It is emphasised that with appropriate water chemistry it is possible to use stainless steel tubes, which is many times cheaper than the Incoloy tubes used elsewhere. The design approach, applicable equation for the design and the results of computation in the form of heat transfer area and some important dimensions of the steam generator are presented.

1993-11-01

214

Reducing the costs of ultrapure water production - a case study  

Energy Technology Data Exchange (ETDEWEB)

The 380 MW combined cycle gas turbine power station in Peterborough changed its water supply from town mains to high purity reverse osmosis permeate in October 2000. The high purity water is produced from secondary treated sewage effluent using advanced membrane technology. Alpheus Environmental and British Gas staff have recently completed a study of the power station's demineralization plant to identify the differences in operating costs associated with the change in feedwater. The results show that the ultrapure water produced after the change to a high purity feed is of improved quality and that the demineralization plant regeneration operating costs have been reduced by over 90%. The demineralization plant availability has increased from 78 to 98% enabling almost 20% more ultra pure water to be produced. The change in feedwater ...

2002-02-01

215

Effect of water purification process in radioactive content: analysis on small scale purification plants; Efecto del proceso de purificacion de agua en el contenido radiactivo: analisis en plantas purificadoras a pequena escala  

Energy Technology Data Exchange (ETDEWEB)

Water from small scale purification plants is a low cost alternative for consumers in comparison to the bottled commercial presentations. Because of its low cost per liter, the consumption of this product has increased in recent years, stimulating in turn the installation of purification systems for these small businesses. The purpose of this study was to estimate the efficiency of small scale purification systems located in the cities of Zacatecas and Guadalupe, Zacatecas, to reduce the radioactive content of water. It was measured the total alpha and beta activity in water samples of entry and exit to process, through the liquid scintillation technique. In general it was observed that the process is more efficient in removing alpha that beta activity. The fraction of total alpha activity removed varied between 27 and 100%, while between 0 and 77% of the total beta activity was removed by the analyzed ...

2009-10-15

216

Wilsonville Advanced Coal Liquefaction Research and Development Facility, Wilsonville, Alabama. Development of VaSTeC autoclave technique and application to pilot plant guidance  

Science.gov (United States)

A precise technique for studying coal liquefaction in a 200 cc stirred-batch-autoclave has been developed. Reaction pressures of up to 4000 psig and temperatures of up to 850/sup 0/F can be employed. The slurry temperature in the autoclave is controlled within 2/sup 0/F by raising or lowering the autoclave which is partially submerged in a sandbath; hence the name: Variable Submergence Temperature Control (VaSTeC). Heatup and cooldown are achieved in 5 and 2 minutes, respectively. A mini-scale vacuum distillation procedure was developed for measurement of 1000/sup 0/F-distillate with a repeatability of 0.3%. About 99% material balance is routinely obtained in the autoclave runs. The following yield repeatabilities have been demonstrated (MAF coal basis):H/sub 2/ cons. (0.1%), C/sub 1/ to C/sub 3/ gas (0.3%), C/sub 4/-1000/sup 0/F distillate (2.4%), and unconverted carbon (0.5%). The autoclave can simulate the yield slate of the thermal liquefaction unit (TLU) of the Wilsonville ...

1986-04-01

217

The Waste Isolation Pilot Plant: A Success Story with International Cooperation  

Energy Technology Data Exchange (ETDEWEB)

The U.S. Department of Energy (DOE) Carlsbad Field Office (CBFO) administers and operates the Waste Isolation Pilot Plant (WIPP) site, which hosts a deep geologic repository for safe disposal of U.S. defense-related TRU waste and is located 42 kilometers (km) east of Carlsbad, New Mexico. CBFO also manages the National Transuranic Waste Program (NTP), which oversees TRU waste management from generation to disposal. The WIPP began receiving waste in March 1999. In some areas of broad international interest, the CBFO has developed a leading expertise through its 25-year WIPP repository and TRU waste characterization activities. In addition to participating in relevant and beneficial experiments, the CBFO will provide the international community convenient access to this information by sponsoring and hosting symposia and workshops on relevant topics and by participation in international waste management organizations and topical meetings. In ...

2002-02-26

218

Testing of the Schlema waste dump leachates cleaning system on a pilot-plant scale. Research report No. 92005  

International Nuclear Information System (INIS)

The concentrations of uranium, arsenic, and radium remain well below the maximum permissible values of < 0.1 mg/l (uranium), < 0.1 mg/l (arsenic) and < 100 mBq/l (radium) due to two separation stages with barium sulfate and GoPur 3000 precipitation and due to iron hydroxide/iron arsenate precipitation. The radioactive arsenates can be separated from the toxic ones by separating the sludge which is analyzed. Processing of radioactive sludges leaves reusable GoPur 3000, sulfuric solutions which contain uranium or solutions which contain carbonate, and radioactive barium sulfate whose radiation intensity of 12 mBq/g is due to the presence of radium. The sludge produced contains adsorbed salts in addition to the dosed chemicals (floated sludges: 40 g/m"3, iron sludges < 20 g/m"3). A solids content < 100 g/m"3 can be selected for both sludge portions. Static-mixer chemicals dosing and technical improvements of the tubular reactor are required for optimization of the ...

219

Gamma-ray pulse height spectrum analysis on systems with multiple Ge detectors using a spectrum summing  

Energy Technology Data Exchange (ETDEWEB)

A technique has been developed at the Idaho National Engineering Laboratory to sum high resolution gamma-ray pulse spectra from systems with multiple Ge detectors. Lockheed Martin Idaho Technologies Company operates a multi-detector spectrometer configuration at the Stored Waste Examination Pilot Plant facility which is used to characterize the radio nuclide contents in waste drums destined for shipment to Waste Isolation Pilot Plant. This summing technique was developed to increase the sensitivity of the system, reduce the count times required to properly quantify the radionuclides and provide a more consistent methodology for combining data collected from multiple detectors. In spectrometer systems with multiple detectors looking at non homogenous waste forms it is often difficult to combine individual spectrum analysis results from each detector to obtain a meaningful result for the total waste ...

1997-05-01

220

Final environmental impact statement. Waste Isolation Pilot Plant  

Energy Technology Data Exchange (ETDEWEB)

In accordance with the National Environmental Policy Act (NEPA) of 1969, the US Department of Energy (DOE) has prepared this document as environmental input to future decisions regarding the Waste Isolation Pilot Plant (WIPP), which would include the disposal of transuranic waste, as currently authorized. The alternatives covered in this document are the following: (1) Continue storing transuranic (TRU) waste at the Idaho National Engineering Laboratory (INEL) as it is now or with improved confinement. (2) Proceed with WIPP at the Los Medanos site in southeastern New Mexico, as currently authorized. (3) Dispose of TRU waste in the first available repository for high-level waste. The Los Medanos site would be investigated for its potential suitability as a candidate site. This is administration policy and is the alternative preferred by the DOE. (4) Delay the WIPP to allow other candidate sites to be evaluated for TRU-waste disposal. This ...

1980-10-01

221

SCE go-ahead for 100-MW coal fired combined cycle plant  

Energy Technology Data Exchange (ETDEWEB)

Preliminary plans for the 90 to 100-MW coal-fired combined cycle plant due to be built by a team headed by Southern California Edison and Texaco in the mid-1980s are reviewed. The basic operating goals call for having a gasifier with a 1,000 ton coal capacity per day feeding a 70-MW turbine which then provides waste heat to run a 30-MW steam turbine. Texaco will have responsibility for the gasifier part of the facility with the turbine-generator vendor charged with providing both gas and steam turbine equipment. If the 100-MW demonstration plant achieves 32 to 33% design efficiency, then a commercial plant with expansion turbines and steam reheat should hit 38% and require 20 to 30% less water than a conventional coal fired plant.

1980-01-01

222

How is Regeneration of Plants after Mowing Affected by Shoot Size in Two Species-Rich Meadows with Different Water Supply?  

British Library Electronic Table of Contents (United Kingdom)

Mowing a meadow is an example of an equalizing process that reduces differences among species by removing aboveground biomass approximately 5?cm above ground. This regular disturbance that affects all plants prevents competitive exclusion of small species and thus allows coexistence of numerous species differing in shoot size. In this paper we search for the mechanism behind this by comparing the shoot biomass of 41 common species in dry and wet species-rich meadows in mown and recently abandoned plots in June (before mowing) and in October. We asked the following questions: i) Do the plants differ in proportion of biomass lost by mowing? ii) Are the mown plants able to compensate for biomass lost by mowing? iii) Is the compensatory ability of mown plants related to their size? iv) Is the ...

2010-01-01

223

Benefit analysis and evaluation of pumped-storage plant in Taipower system  

Energy Technology Data Exchange (ETDEWEB)

The operation of pumped-storage plants (PSP) is based on the daily load variations of power demand. It performs power generation at peak load times during the day, and pumps water up into the reservoir during the off-peak times at night. In the Taipower system in Taiwan, there are two pumped storage plants with ten units. These had a total installed capacity of 2,602 MW or a 12 percent capacity at the end of 1995. The plants were able to reduce system generation costs and improve reliability. A Pumped-Storage Plant Benefit Analysis (PSPBA) program was established using the principle of economic dispatch in 1985. This paper explains the rules of the program, the analysis results of the past 10 years, and a a cost benefit evaluation. It was found that the advantages of PSP are not only in supplying the power for peak load, but also in decreasing the total fuel cost. 5 figs., 4 refs.

1995-12-31

225

Forest Carbon Projects: Avoided Deforestation (Hovani)  

Science.gov (United States)

... entitled: In-country Pilot Activities: Reducing Emissions from Deforestation and Degradation)...

227

DEVELOPMENT OF THE PILOT WARNING INSTRUMENT ...  

Science.gov (United States)

... multivibrators and amplifiers arranged to operate as described above. ... The first of the multivibrators is triggered by the trailing edge of the ...

1962-02-01

228

Breath Test for Chemicals (Volatile Organic Compounds)  

Science.gov (United States)

Breath Tests; Human Volunteers; Pilot Study

2011-09-16

229

Instrumentation for monitoring and control of water chemistry for light-water-cooled nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

Based on the IAPWS technical guidance on ''Instrumentation for Monitoring and Control of Cycle Chemistry for Steam-Water Circuits of Fossil-Fired and Combined Cycle Power Plants,'' the latest situation regarding instrumentation for nuclear power plants is discussed. As a result of the discussion, it is concluded that: (1) Reliable and safe operation of plants is established by the application of suitable chemical conditions in plant cooling systems, which should be supported by the selection of suitable control targets for monitoring and by the application of reliable instruments. (2) The minimum level of key instrumentation consists of on-line as well as off-line instruments for monitoring the key parameters: - on-line: pH, conductivity, cation conductivity, O{sub 2} and H{sub 2} concentrations, electrochemical corrosion potential; - off-line: ...

2010-05-15

230

Technical requirements for the ASME PRA standard for nuclear power plant applications  

Energy Technology Data Exchange (ETDEWEB)

In 1998 the American Society of Mechanical Engineers (ASME) formed the Committee on Nuclear Risk Management (CNRM) and a Project Team to develop a standard on PRAs for use in risk informed applications. This ASME standard is being developed to help provide an adequate level of quality in PRAs that are being used to support ASME initiatives to risk informed in-service inspection (ISI) and in-service testing (IST) of nuclear power plant components. A related need supported by the industry and the U.S. Nuclear Regulatory Commission is to reduce the level of effort that is being expended in pilot applications of risk informed initiatives to address questions about the sufficiency of quality in the supporting PRA models. The purpose of this paper is to discuss the authors' views on some of the technical issues that were encountered in the effort to develop the ASME PRA standard. Draft 12 of this standard has been issued for comment, and is ...

2000-07-01

231

Technical requirements for the ASME PRA standard for nuclear power plant applications  

International Nuclear Information System (INIS)

In 1998 the American Society of Mechanical Engineers (ASME) formed the Committee on Nuclear Risk Management (CNRM) and a Project Team to develop a standard on PRAs for use in risk informed applications. This ASME standard is being developed to help provide an adequate level of quality in PRAs that are being used to support ASME initiatives to risk informed in-service inspection (ISI) and in-service testing (IST) of nuclear power plant components. A related need supported by the industry and the U.S. Nuclear Regulatory Commission is to reduce the level of effort that is being expended in pilot applications of risk informed initiatives to address questions about the sufficiency of quality in the supporting PRA models. The purpose of this paper is to discuss the authors' views on some of the technical issues that were encountered in the effort to develop the ASME PRA standard. Draft 12 of this standard has been issued for comment, and is currently ...

232

Facility Effluent Monitoring Plan for Pacific Northwest National Laboratory Balance-of-Plant Facilities  

Energy Technology Data Exchange (ETDEWEB)

The Pacific Northwest National Laboratory (PNNL) operates a number of research and development (R and D) facilities for the Department of Energy on the Hanford Site. According to DOE Order 5400.1, a Facility Effluent Monitoring Plan is required for each site, facility, or process that uses, generates, releases, or manages significant pollutants or hazardous materials. Three of the R and D facilities: the 325, 331, and 3720 Buildings, are considered major emission points for radionuclide air sampling and thus individual Facility Effluent Monitoring Plans (FEMPs) have been developed for them. Because no definition of ''significant'' is provided in DOE Order 5400.1 or the accompanying regulatory guide DOE/EH-0173T, this FEMP was developed to describe monitoring requirements in the DOE-owned, PNNL-operated facilities that do not have individual FEMPs. The remainder of the DOE-owned, PNNL-operated facilities are referred to as ...

1999-04-02

233

Experience with the operation and fuel supply of the biomass firing plant of the Trocknungsgenossenschaft Lengenfeld eG, a drying cooperative society; Erfahrungen mit Betrieb und Brennstoffbereitstellung der Biomassefeuerung der Trocknungsgenossenschaft Lengenfeld eG  

Energy Technology Data Exchange (ETDEWEB)

The pilot project of the conversion of the green forage drying plant Lengenfeld to biomass firing could not be realized without problems. But the experience until now shows that it is in principle possible. The farmers involved are devoted to the project. For them the cultivation of biomass is an alternative to the abandonment of fields. The present low oil price sets limits to the positive income effect. The aim is an increase of the biomass share in heating energy supply to about 80%. (orig.) [Deutsch] Die Umstellung der Gruenfuttertrocknung Lengenfeld auf Biomassefeuerung ist als Pilotprojekt nicht ohne Probleme moeglich gewesen. Die bisherigen Erfahrungen zeigen jedoch die grundsaetzliche Praktikabilitaet. Die beteiligten Landwirte sind engagiert bei der Sache und schaetzen die Produktionsmoeglichkeit als Alternative zur Flaechenstillegung. Der derzeit niedrige Oelpreis setzt der positiven Einkommenswirkung jedoch enge Grenzen. Eine ...

1994-12-31

234

Effectively use corrosion testing  

Energy Technology Data Exchange (ETDEWEB)

The proper selection of materials of construction is necessary to provide process equipment with optimum performance and corrosion resistance. If properly chosen, the selected material should deteriorate at a uniform, predictable rate, which will allow for maintenance or replacement at scheduled intervals. This concept of risk assessment for predictive maintenance is a minimum requirement for proper materials selection. Materials selection is based on prior service history, field corrosion tests, pilot-plant tests, and laboratory bench-top tests--in that relative order of usefulness. Corrosion test methods are usually divided into two groups: laboratory and field (plant-site) tests. The main difference between the two is that field test specimens are exposed to actual process conditions will all of the variables involved, while laboratory tests are a simulation of field conditions, even if actual process fluids are involved. The paper ...

1995-04-01

235

Economic production and processing of agricultural fibre plants for high quality applications in automotive, building and furniture industry  

Energy Technology Data Exchange (ETDEWEB)

The demand for high-quality fibres and shives from hemp and flax as an alternative raw material for the automotive and building industry is increasing. Fibres are used primarily for composite reinforcement instead of synthetic fibres. Shives are used for animal bedding, but processing trials in wood industry for the production of low weight particle boards from shives are also very promising. Fibre producers require experience in cultivation and harvesting as well as modern processing technologies in order to supply flax fibres or shives at competitive prices under the changing conditions of international raw material markets. A complete processing line has been developed, installed and tested at the Leibniz Institute for Agricultural Engineering (ATB) to study all the processing stages of fibre production. The new ATB line can produce high quality fibres and shives from retted and unretted hemp, flax and oilseed flax straw without technical changes of the machine line. The ATB ...

2010-07-01

236

Economic evaluation of the solar carbothermic reduction of ZnO by using a single sensitivity analysis and a Monte-Carlo risk analysis  

Energy Technology Data Exchange (ETDEWEB)

The technical feasibility of the solar carbothermal reduction of ZnO has been successfully demonstrated in a pilot plant. The economics of this process is addressed by means of a single sensitivity analysis and a Monte-Carlo risk analysis. A medium-term and a long-term scenario have been investigated, each for a 5 and a 30 MW{sub th} plant. For a discount rate of 15% the zinc production costs vary between 482 and 245 $/t for the medium-term scenario and between 312 and 146 $/t for the long-term scenario, respectively. These costs do not account for the zinc oxide input material. In addition, a risk analysis was conducted for the 30 MW{sub th} long-term scenario. For each input parameter, a probability distribution was estimated and the probability distribution of the zinc production cost was calculated by means of a Monte-Carlo method. The expected mean zinc production costs vary from 95 $/t for a discount rate of 0%-286 ...

2007-07-15

237

Analyses of mixed-hydrocarbon binary thermodynamic cycles for moderate-temperature geothermal resources  

Energy Technology Data Exchange (ETDEWEB)

A number of binary geothermal cycles utilizing mixed hydrocarbon working fluids were analyzed with the overall objective of finding a working fluid which can produce low-cost electrical energy using a moderately-low temperature geothermal resource. Both boiling and supercritical shell-and-tube cycles were considered. The performance of a dual-boiling isobutane cycle supplied by a 280/sup 0/F hydrothermal resource (corresponding to the 5 MW pilot plant at the Raft River site in Idaho) was selected as a reference. To investigate the effect of resource temperature on the choice of working fluid, several analyses were conducted for a 360/sup 0/F hydrothermal resource, which is representative of the Heber resource in California. The hydrocarbon working fluids analyzed included methane, ethane, propane, isobutane, isopentane, hexane, heptane, and mixtures of those pure hydrocarbons. For comparison, two fluorocarbon refrigerants were also analyzed. ...

1981-02-01

238

Environmental impacts of nuclear and coal-fired power plants  

International Nuclear Information System (INIS)

The current situation in the development of nuclear power in the world and in Czechoslovakia is briefly outlined and the possibilities are discussed of alternative energy resources. The environmental impact is described of conventional power plants firing coal; sulphur and nitrogen oxides are mentioned and their environmental impacts shown. Their quantities and the quantities of other gaseous, liquid and soid wastes produced by coal power plants are given. Annual estimates are presented of radioactive material emissions; trace amount emissions of toxic metals and their ecological risks are shown. Concern over the increasing concentration of CO_2 in the atmosphere is voiced. For nuclear power plants, the amount of radionuclides in stack emission and of those released into water flows is tabulated. Their effect on the aqueous ecosystem is characterized as is thermal pollution of water ...

1984-01-01

239

Economic evaluation of four types of dry/wet cooling applied to the 5-MWe Raft River geothermal power plant  

Energy Technology Data Exchange (ETDEWEB)

A cost study is described which compared the economics of four dry/wet cooling systems to use at the existing Raft River Geothermal Plant. The results apply only at this site and should not be generalized without due consideration of the complete geothermal cycle. These systems are: the Binary Cooling Tower, evaporative condenser, Combin-aire, and a metal fin-tube dry cooling tower with deluge augmentation. The systems were evaluated using cooled, treated geothermal fluid instead of ground or surface water in the cooling loops. All comparisons were performed on the basis of a common plant site - the Raft River 5 MWe geothermal plant in Idaho. The Binary Cooling Tower and the Combin-aire cooling system were designed assuming the use of the isobutane/water surface condenser currently installed at the Raft River Plant. The other two systems had the isobutane ducted ...

1982-07-01

240

Steam generator design improvements for the candu wolsung nuclear power plant  

International Nuclear Information System (INIS)

Design considerations are given for the secondary side region of a vertical U-tube nuclear stream generator with an integral preheater. The thermal shield design, the novel recirculating water flow distribution scheme, the high porosity tube supports used in the parallel flow regions, and the U-bend supports are discussed for the Wolsung Plant steam generators. Experimental and analytical development programs undertaken to verify the design features are outlined.

1978-01-01

241

Reliability assessment of hydrothermal generation systems containing pumped storage plant  

Energy Technology Data Exchange (ETDEWEB)

Previous models and evaluation techniques based on the Monte Carlo simulation for the reliability assessment of mixed hydrothermal generation systems are extended. Models for reservoirs on multiple rivers and pumped storage plants are developed. Operating and water management policies are extended to include the relative economical effects of operating alternative sources of generation. These effects and the benefits are described and discussed using an extended IEEE reliability test system. (Author).

1991-11-01

242

Combined-cycle cogen plant a successful good neighbor  

Energy Technology Data Exchange (ETDEWEB)

This article describes a new natural-gas-fired combined cycle cogeneration plant in Bellingham, Washington. The topics of the article include community impact, siting constraints, natural gas fuel, the flexibility provided by the steam turbine, the cooling tower and pumps, air-quality, noise, and cooling water system constraints, and community relations program.

1993-04-01

243

Workshop on stems and trunks in plant form and function. Final report  

Energy Technology Data Exchange (ETDEWEB)

This document is the final report on the workshop on stems and trunks in plant form and function relating to DOE grant DE-FG06-93ER20128 which took place at Oregon State University in February 1994. The resulting book is organized into four sections and a synthesis: roles of stem architecture in plant performance, roles of stems in transport and storage of water, roles of live stem cells in plant performance, and the roles of stems in preventing or reacting to response to plant injury. The synthesis stemmed from debated and discussion by the authors and a few dozen other workshop participants. The authors cover many stem functions, although the list is not exhaustive, and the focus is on terrestrial woody tree stems, primarily of temperate and boreal zones. More research on trunks, branches and twigs is important for a baseline understanding of plant biology. In ...

1995-03-01

244

East-Asia nuclear/fossil power plant competitiveness  

Energy Technology Data Exchange (ETDEWEB)

The competitiveness of a new nuclear plant vs. a new oil or gas fired combined cycle plant or a coal fired plant in East-Asia, is reviewed in the paper. Both the nuclear and the fossil fired plants are evaluated as either utility financed or independent power producer (IPP) financed. Two types of advanced light water reactors (ALWRs) are considered in this paper, namely evolutionary ALWRs (1200 MWe size) and passive ALWRs (600 MWe class). A range of capital and total generation costs for each plant type is reported here. The comparison centers on three elements of overall competitiveness: generation costs, hard currency requirements, and employment requirements. Each of these aspects is considered perspective. Year-by-Year generation cost history over the plant lifetime is shown in some cases. It is found here that a utility financed ...

1996-12-31

245

International Water Power and Dam Construction Handbook 1993  

Energy Technology Data Exchange (ETDEWEB)

In this handbook, technical reports on a number of hydro plants under construction are provided. In addition tables of compiled data are presented on a world-wide basis for the following: turbine and hydro generator contracts; hydropower resource potential and development; pumped storage plants; the major dams and hydro plants; roller compacted concrete dams and concrete faced rockfill dams; small hydropower. An address database of international organizations of relevance to hydropower development, national power authorities and nation committees of the International Commission an Large Dams is included. A final and major section of the handbook is a buyer's guide providing extensive company data and information on products and services. (UK)

1993-01-01

246

The controllability analysis of the purification system for heavy water reactors  

International Nuclear Information System (INIS)

The heavy water reactor such as Wolsung No.1 and No.2 has a purification system to purify the reactor coolant. The control system regulates the coolant temperature to protect the ion exchanger. After the fuel exchanges of operating plant, the increase of the coolant pressure makes the purification temperature control difficult. In this paper, the controllability of the control dynamics of the purification system was analysed and the optimal parameters were proposed. To reduce the effects of the flow disturbance, the feedforward control structure was proposed and analysed.

2001-10-01

247

The Philadelphia Marriott: A convention center flagship hotel  

Energy Technology Data Exchange (ETDEWEB)

This article describes the state-of-the-art HVAC system at the Philadelphia Marriott Hotel. Thermal comfort and indoor air quality are emphasized. The system uses a hybrid gas absorption/electric centrifugal chilled water plant, variable flow pumping, water-side economizers to provide free cooling, central air handling units with air-side economizers and flow monitoring equipment.

1997-01-01

248

Photosynthesis and Growth of Water Hyacinth under CO2 Enrichment 1  

UK PubMed Central (United Kingdom)

Water hyacinth (Eichhornia crassipes [Mart.] Solms) plants were grown in environmental chambers at ambient and enriched CO2 levels (330 and 600 microliters CO2...Full Text Available

1986-10-01

249

Molecular Characterization of Vibrio cholerae O139 Bengal Isolated from Water and the Aquatic Plant Eichhornia crassipes in the River Ganga, Varanasi, India  

UK PubMed Central (United Kingdom)

A collection of ten strains of Vibrio cholerae O139, comprising six isolates from Eichhornia crassipes, two from water of the River Ganga, and one each from a well...Full Text Available

2003-04-01

250

In situ air stripping using horizontal wells. Innovative technology summary report  

Energy Technology Data Exchange (ETDEWEB)

In-situ air stripping employs horizontal wells to inject or sparge air into the ground water and vacuum extract VOC`S from vadose zone soils. The horizontal wells provide better access to the subsurface contamination, and the air sparging eliminates the need for surface ground water treatment systems and treats the subsurface in-situ. A full-scale demonstration was conducted at the Savannah River Plant in an area polluted with trichloroethylene and tetrachloroethylene. Results are described.

1995-04-01

251

Safe design of mud ditches in briquetting factories  

Energy Technology Data Exchange (ETDEWEB)

The authors study technological safety of installing a water spray pressure vessel between electrostatic deduster and coal sludge ducts. These sprays are in use elsewhere for steam generator ash removal. Dust ignition and explosion tests were carried out to examine flame and pressure wave propagation through the vessel into ducts. Water jet diameter, amount of water sprayed and coal dust removed were varied. Pressure waves exceeded 250 Pa. Test results show the vessel to be suitable for installation in briquetting plants due to its flame and explosion barrier effect and extermination of smoldering dust fires. The only disadvantage of the vessel is seen as its water and electric power consumption: about 8 m/sup 3//h of water and 1.5 kW/h of power per vessel serving dedusters of a 2,200 m/sup 2/ rotary brown coal dryer. (MOS).

1987-06-01

252

Growth and gas exchange response to water shortage of a maize crop on different soil types  

British Library Electronic Table of Contents (United Kingdom)

The effect of water shortage on growth and gas exchange of maize grown on sandy soil (SS) and clay soil was studied. The lower soil water content in the SS during vegetative growth stages did not affect plant height, above-ground biomass, and leaf area index (LAI). LAI reduction was observed on the SS during the reproductive stage due to early leaf senescence. Canopy and leaf gas exchanges, measured by eddy correlation technique and by a portable photosynthetic system, respectively, were affected by water stress and a greater reduction in net photosynthetic rate (A N) and stomatal conductance (g s) was observed on SS. Chlorophyll and carotenoids content was not affected by water shortage in either condition. Results support two main conclusions: (1) leaf photosynthetic capacity was unaffec...

2009-01-01

253

Tritium analysis in environmental samples around Nuclear Power Plants and nationwide surveillance of radionuclides in some environmental samples(meat and drinking water)  

Energy Technology Data Exchange (ETDEWEB)

12 kind of environmental samples such as soil, underground water, seawater, etc. around the Nuclear Power Plants(NPP) and surface seawater around the Korea peninsula were sampled, For the samples of rain, pine-needle, air, seawater, underground water, chinese cabbage, grain of rice and milk sampled around NPP, and surface seawater and rain sampled all around country, tritium concentration was measured, The tritium concentration in the tap water and the gamma activity in the domestic and imported beef that were sampled at ward in the large city in Korea(Seoul, Pusan, Taegu, Taejun, Inchun, Kwangju) were analyzed for the meat and drinking waters. As the results of analyzing, tritium concentration in rain and tap water were very low all around country, but a little higher around the NPP than general surrounding. At the Wolsung NPP, tritium concentration was descend ...

2001-12-15

254

New intelligent monitor for CANDU type NPP  

International Nuclear Information System (INIS)

Nuclear energy provides a third of Europe's electricity with nearly no greenhouse-gas emissions. Sustained efforts are now being conducted to harmonize regulations all over Europe through WENRA and to converge on technical nuclear safety practices within the TSO network ETSON (European Technical Safety Organizations Network). In CANDU type NPP the tritiated water occurs by the neutron bombardment of deuterium. The tritiated water vapors imply health hazard (in the critical organs of the body the water presents a 10 day average biological half-life) and the early detection in nuclear plants of tritium emissions is important because the tritiated water vapors have the same characteristics as of atmospheric water vapors. By detecting tritiated vapors, the monitoring system ensures the following objectives: (a) indicates levels of tritium generally due to heavy ...

2009-10-12

255

Test plan for single well injection/extraction characterization of DNAPL  

Energy Technology Data Exchange (ETDEWEB)

Soils and groundwater beneath an abandoned Process sewer line in the A/M Area of the Savannah River Site (SRS) contain elevated levels of volatile organic compounds, specifically trichloroethylene (TCE) and tetrachloroethylene (PCE), two common chlorinated solvents. These compounds have low aqueous solubilities, thus when released to the subsurface in sufficient quantity, tend to exist as immiscible fluids or nonaqueous phase liquids (NAPLs). Because chlorinated solvents are also denser than water, they are referred to by the acronym DNAPLS, or dense non aqueous Phase liquids. Technologies targeted at the efficient characterization or removal of DNAPL are not currently proven. For example, most DNAPL studies rely on traditional soil and water sampling and the fortuitous observation of immiscible solvent. Once DNAPL is identified, soil excavation (which is only applicable to small contained spill sites) is the only ``proven`` cleanup method. New ...

1995-12-01

256

Test plan for Geo-Cleanse{reg_sign} demonstration (in situ destruction of dense non-aqueous phase liquid (DNAPL))  

Energy Technology Data Exchange (ETDEWEB)

Soils and groundwater beneath an abandoned process sewer line in the A/M Area of the Savannah River Site (SRS) contain elevated levels of volatile organic compounds, specifically trichloroethylene (TCE) and tetrachloroethylene (PCE), two common chlorinated solvents. These compounds have low aqueous solubilities, thus when released to the subsurface in sufficient quantity, tend to exist as immiscible fluids or nonaqueous phase liquids (NAPLs). Because chlorinated solvents are also denser than water, they are referred to by the acronym DNAPLs, or dense non-aqueous phase liquids. Technologies targeted at the efficient characterization or removal of DNAPL are not currently proven. For example, most DNAPL studies rely on traditional soil and water sampling and the fortuitous observation of immiscible solvent. Once DNAPL is identified, soil excavation (which is only applicable to small contained spill sites) is the only proven cleanup method. New ...

1996-09-01

257

Liquid radwaste processing with spiral wound reverse osmosis  

International Nuclear Information System (INIS)

Two different reverse osmosis systems were investigated. The first was a 50-element plant-scale system that is used to treat 2200 m"3 of AECL liquid radwastes annually.It uses thin-film composite (TFC) membranes and operates at an applied pressure of 2760 kPa, with a fixed crossflow of about 40 L/min. The other system uses the same thin-film composite membranes for waste processing but is a two-element pilot-scale system. It is operated at pressures m ranging between 1500 and 7000 kPa, at a fixed crossflow of 55 L/min. The average lifetime of the thin-film composite membranes in the plant-scale processing application at AECL is about 3000 h. After this service life has expired the rejection efficiency declines rapidly from 99.5% to about 95% as the membranes become impaired from chemical cleaning procedures that are required after each 100 m"3 of waste is treated. The permeation flux for the plant-scale ...

1996-02-25

258

Evaluation of new corrosion resistant superheater tubings in high efficiency waste-to-energy plants  

Energy Technology Data Exchange (ETDEWEB)

In order to develop new corrosion resistant superheater tubes capable of functioning efficiency under temperature and pressure conditions of 500 C and 100 ata used in high efficient waste-to-energy (WTE) plants, field corrosion tests were conducted on eight single tube materials and two welded overlay materials at metal temperatures of 450 C and 550 C for 700 and 3,000 hours, respectively, in three typical japanese waste incineration plants. The test results indicate that austenitic alloys containing higher concentrations of [Cr + Ni + Mo] show excellent corrosion resistant properties and new alloys of JHN24 and HR30M have good corrosion resistance. The different corrosion rate found for each of the three plants could be explained by differences in the severity of corrosion factors, such as, gas temperature, concentration of molten salts due to Cl content of deposits, and heavy metal [ZnO + PbO] content etc. It was also ...

1997-08-01

259

Water chemistry in the water-vapor circuit at Angra II: evolution of the operational concepts and canceling of the condensed polishing system; Quimica da agua do circuito agua-vapor de Angra II: evolucao do conceito operacional e o cancelamento do sistema de polimento do condensado  

Energy Technology Data Exchange (ETDEWEB)

The chemical operational concept originally established for the water-steam circuit of Angra II nuclear power plant has undergone several modifications throughout the development of the project. This work discusses the two main modifications giving special attention to the costs involved and analyses the main points and the consequences of such modifications 1 ref., 4 figs., 2 tabs.

1995-12-31

260

Identification of elements in plant drugs and their water infusion using X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The present work gives preliminary results of analysis of drug mixtures (NEPHROSAL tea bag) and its water infusion. In a sample of dried drugs the elements K, Ca, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, Pb were identified, whereas in their water infusion only Ca, Mn, Zn and Sr were found. The method applied was radionuclide X-ray fluorescence analysis using a radionuclide source "1"0"9Cd, a Si/Li semiconductor detector and a multichannel analyzer Canberra 8100. (author) 6 refs.; 3 figs.

8100-01-01

261

Effect of synthetic detergents on germination of fern spores  

Energy Technology Data Exchange (ETDEWEB)

Synthetic detergents constitute one of the most important water pollutants by contaminating the lakes and rivers through domestic and industrial use. Considerable information is now available for the adverse effects of detergents an aquatic fauna including fish, algae, and higher aquatic plants. Marked inhibition of germination in orchids and brinjals and of seedlings growth in raddish suggest that rapidly growing systems could be sensitive to detergent polluted water. The present study of the effect of linear alkyl benzene sulphonate on germination of the spores of a fern, Diplazium esculentum aims at the understanding of the effects of water pollution on pteridophytes and the development of spore germination assay for phytoxicity evaluation.

1986-12-01

262

Water-seal vacuum pumps as compact units for deaeration of steam turbine condensers in conventional and nuclear plants  

International Nuclear Information System (INIS)

On all steam turbines operating with condensation the air leakage penetrating from the part of the plant which is under vacuum must be eliminated, in order to maintain the vacuum created by physical conditions. In order to attain effective air bleed-off, the water-steam-air mixture is conveyed via the super-cooling bundles in the condenser. In this way the steam partial pressure decreases and the air partial pressure increases at a constant condenser pressure. In this procedure the mixture is supercooled by about 4"0C compared with the saturate steam temperature appertaining to the condenser pressure. The values of volume of air leakage are the result of a year's experience on existing plant. (orig.).

263

ICPP water inventory study project summary report  

Energy Technology Data Exchange (ETDEWEB)

The Idaho Chemical Processing Plant (ICPP) Water inventory Study was initiated in September 1993 with the formation of a joint working group consisting of representatives from DOE-ID, State of Idaho INEL Oversight Program, US Geological Survey, and INEL employees to investigate three issues that had been identified by the INEL Oversight Program at ICPP: (1) the water inventory imbalance at ICPP, (2) the source of water infiltrating into the Tank Farm vault sumps, and (3) the source of water providing potential recharge to perched water bodies underlying ICPP. These issues suggested that water was being lost from the ICPP distribution system. The INEL Oversight Program was concerned that the unaccounted for water at ICPP could be spreading contaminants that have been released over the past 40 years of operations of ICPP, ...

1994-01-01

264

Changes in water qualities and human activities at the urban coastal areas; Toshienganiki niokeru suishitsuhenkann to ningen katsudo  

Energy Technology Data Exchange (ETDEWEB)

The population masses in many coastal zones in Japan, and human activities are greatly effected. The representative water area is the Tokyo Bay. The population of the Tokyo Bay reaches 26 million at present, and a mass of organic substance and nutrient salt flow into it through rivers and sewage-treatment plants, etc. With the improvement of pollution source countermeasure and sewerage in the area, the inflow load to the Bay gradually decreases, but in the inner bay, red tide is generating in the summertime mainly. And, the anoxic water areas observed in bottom layer in summertime make large effects on the seafood. It is a large theme to clarify formation process of the anoxic water area and to solve this problem for the Tokyo Bay in the twenty-first century. In this paper, changes in water qualities and human activities and fundamental approach of water quality ...

2000-01-05

265

A Feasibility Study to Lower Steam Generator Low Water Level Trip Setpoint to Reduce Unnecessary Scram Frequency for KORI 3,4 Plant  

Energy Technology Data Exchange (ETDEWEB)

The steam generator low water level trip setpoint of KORI NPP units 3 and 4(KNU 3 and 4), three-loop Westinghouse pressurized water reactor, is higher than that of OPR1000. In addition, steam generator downcomer water level in KNU 3 and 4 could fluctuate easily during a transient because of smaller downcomer water inventory, compared to the total water inventory in the steam generator. Due to these reasons, there is a higher possibility of unnecessary reactor trips caused by the steam generator low-low water level in KNU 3 and 4. Its operating history shows that most of reactor trips were caused by steam generator low-low level reactor trip signal. Such reactor trips, especially unnecessary ones, result in time and economic losses. In this paper, a feasibility study was performed to reduce unnecessary reactor trip by changing steam generator low-low ...

2008-10-15

266

A Feasibility Study to Lower Steam Generator Low Water Level Trip Setpoint to Reduce Unnecessary Scram Frequency for KORI 3,4 Plant  

International Nuclear Information System (INIS)

The steam generator low water level trip setpoint of KORI NPP units 3 and 4(KNU 3 and 4), three-loop Westinghouse pressurized water reactor, is higher than that of OPR1000. In addition, steam generator downcomer water level in KNU 3 and 4 could fluctuate easily during a transient because of smaller downcomer water inventory, compared to the total water inventory in the steam generator. Due to these reasons, there is a higher possibility of unnecessary reactor trips caused by the steam generator low-low water level in KNU 3 and 4. Its operating history shows that most of reactor trips were caused by steam generator low-low level reactor trip signal. Such reactor trips, especially unnecessary ones, result in time and economic losses. In this paper, a feasibility study was performed to reduce unnecessary reactor trip by changing steam generator low-low ...

2008-10-01

267

TOC in water/steam cycles. Zittau Colloquium on Power Plant Chemistry; TOC in Wasser/Dampf-Kreislaeufen. Zittauer Kraftwerkschemisches Kolloquium  

Energy Technology Data Exchange (ETDEWEB)

Many power plants use treated surface water as boiler feedwater and have difficulties in keeping within the limits for organic substances in feedwater (TOC < 200 ppb) or acid conductivity in steam condensate (< 0.2 {mu}S/cm). The characteristics of surface water and the role of organic substances in boiler feedwater are explained and discussed. [German] Viele Kraftwerke bereiten fuer die Erzeugung von Kesselspeisewasser Oberflaechenwasser auf und haben Probleme, die Richtlinien fuer organische Stoffe im Speisewasser (TOC < 200 ppb) oder Saeure-Leitfaehigkeit in Dampfkondensaten (< 0,2 {mu}S/cm) einzuhalten. Die besonderen Eigenschaften von Oberflaechenwaessern und die Bedeutung organischer Stoffe in Kesselspeisewasser werden erlaeutert und diskutiert. (orig.)

2000-07-01

268

Growth and transpiration of maize and winter wheat in response to water deficits in pots and plots  

British Library Electronic Table of Contents (United Kingdom)

Pots used for experiments conducted on plants grown in them create rooting environments that are affected by limited soil volume, which can affect various physiological processes, including transpiration, and plant growth. However, the applicability of results from pot experiments to the field has received limited attention. The objective of this study was to compare the growth and transpiration of maize (Zea mays L.) and winter wheat (Triticum aestivum L.) when grown in pots and field plots under various constant water deficits. The experiments were conducted under similar environmental conditions for both pots and plots. Transpirational responses at both transient (RTTr) and daily (RDTr) time scales to a decreasing fraction of available soil water (FASW) were analyzed. For a comparable F...

2011-01-01

269

Environmental mitigation for SCC initiation of BWR core internals by hydrogen injection during start-up  

Energy Technology Data Exchange (ETDEWEB)

Hydrogen injection into the reactor water has been applied to many BWR power stations. Since hydrogen injected accelerates recombination of oxidant generated by water radiolysis, oxidant concentration, such as dissolved oxygen concentration in reactor water can be reduced. As the result of the reduction of oxidant concentration, Electrochemical Corrosion Potential (ECP) at the surface of structural material can be lowered. Lowered ECP moderates Stress Corrosion Cracking (SCC) sensitivity of structural materials, such as stainless steels. As usual, hydrogen injection system begins to work after the plant start-up is finished, when the condition of normal operation is established. Accordingly, Hydrogen Water Chemistry (HWC) does not cover all the period of plant operation. As far as SCC crack growth is considered, loss of HWC during plant ...

2004-07-01

270

Effect of design improvements in heavy water management systems to reduce heavy water losses and tritium releases at Wolsong 2,3 and 4  

International Nuclear Information System (INIS)

Design improvements are being incorporated into the heavy water management systems at Wolsong 2,3 and 4 to reduce the load on the vapour recovery driers and upgraders and the heavy water losses via the stack. There will also be improvements to monitor heavy water and tritium releases. This paper describes the improvements, gives background on heavy water balance mechanism, the historical trends for heavy water recovery/losses and estimated dose to the member of the public critical group resulting from the airborne and waterborne releases. The measured tritium activity levels in the heat transport system (HTS) and moderator system at Wolsong 1 are given. Using these activity levels and heavy water loss data, tritium losses from the dried and ventilated areas are estimated. A qualitative assessment of expected heavy water and tritium releases ...

1994-03-01

271

EDI as a Treatment Module in Recycling Spent Rinse Waters  

Energy Technology Data Exchange (ETDEWEB)

Recycling of the spent rinse water discharged from the wet benches commonly used in semiconductor processing is one tactic for responding to the targets for water usage published in the 1997 National Technology Roadmap for Semiconductors (NTRS). Not only does the NTRS list a target that dramatically reduces total water usage/unit area of silicon manufactured by the industry in the future but for the years 2003 and beyond, the NTRS actually touts goals which would have semiconductor manufacturers drawing less water from a regional water supply per unit area of silicon manufactured than the quantity of ultrapure water (UPW) used in the production of that same silicon. Achieving this latter NTRS target strongly implies more widespread recycling of spent rinse waters at semiconductor manufacturing sites. In spite of the fact that, by most ...

1999-08-11

272

Variable-speed generation enhances hydro operation  

Energy Technology Data Exchange (ETDEWEB)

Two major developments have given impetus to wider adoption of variable-speed turbine/generators in hydroelectric plants, both essentially environmental: (1) the need for stream-bed stability below river dams, and (2) the need to minimize fish damage. Also, the need to stabilize pumped-storage and generating efficiencies to match extreme changes in head levels has been a driving force. Variable-speed operation in hydro applications is relatively new to North America. In other parts of the world, it has been used in pumped-storage plants since 1971. In the US, and increasing potential exists for variable-speed hydro, considering the 30 pumped-storage plants already in operation and several river plants struggling with high head fluctuations--including four at stations operated by the Bonneville Power Administration. Several modifications to hydro-plant hardware and operating ...

1993-07-01

273

The efficiency of coal-fired combined-cycle powerplants  

Energy Technology Data Exchange (ETDEWEB)

Concepts involving combined gas-turbine/steam-turbine power-generation plants, in which the fuel gas for the gas turbine is produced via the gasification of coal, are now extremely advanced. This technology already permits efficiencies of around 50% current development targets view 65% as achievable. In conventional technology, efficiencies are tied to conditions, such as air and cooling-water temperatures, at the particular location. In combined-cycle power plants, the properties of the fuel coal also play an important part. There are, in face, coals which can be more advantageously used in a combined-cycle power plant than in a conventional one. These differences, combined with advantageous concepts for coal-fired combined-cycle power-generating plants, are presented and analyzed. Particular attention is devoted to individual losses occurring at coal conversion, thermodynamic ...

1996-12-01

274

Environmental costs and benefits case study: nuclear power plant. Quantification and economic valuation of selected environmental impacts/effects. Final report  

International Nuclear Information System (INIS)

This case study is an application, to a nuclear power plant, of the methodology for quantifying environmental costs and benefits, contained in the regional energy plan, adopted in April, 1983, by the Northwest Power Planning Council, pursuant to Public Law 96-501.The study is based on plant number 2 of the Washington Public Power Supply System (WNP-2), currently nearing completion on the Hanford Nuclear Reservation in eastern Washington State. This report describes and documents efforts to quantify and estimate monetary values for the following seven areas of environmental effects: radiation/health effects, socioeconomic/infrastructure effects, consumptive use of water, psychological/health effects (fear/stress), waste management, nuclear power plant accidents, and decommissioning costs. 103 references.

275

The application of high pH operation to the secondary water chemistry at Genkai Nuclear Power Station  

International Nuclear Information System (INIS)

PWR plants have made efforts to maintain the long-term integrity of the steam generators (SG) by reducing the amount of corrosion products entering the secondary side of the SG. Iron entered the SG can cause several problems: degraded heat conductivity of the SG tubes in locations where iron is deposited, water level oscillations in the SG due to tube support plate hole blockage, and initiation and propagation of inter-granular attacks (IGA) and stress corrosion cracking (SCC). One of the most effective measures, high all-volatile treatment (AVT) chemistry has been applied to actual plants to reduce the flow-accelerated corrosion (FAC) coming from the carbon steel piping. The secondary water chemistry at Genkai NPS 1 and 2 changed, from the Low AVT chemistry to the High AVT chemistry, in November 2006. In this paper, we will describe the results of experiments in applying the use of High pH ...

2009-02-01

276

Synfuels from coal lessons: from South Africa  

Energy Technology Data Exchange (ETDEWEB)

The most significant lessons provided by these developments at SASOL are the importance of long-range planning and the need for establishing a commercialized technology base in synfuels. These are necessary to reduce our dependence on foreign energy sources and can be accomplished with suitable cooperation between government and private industry and between agencies within the government. The Fischer-Tropsch process is not the only method for producing gasoline from coal, but so far it is the only one commercially proven. Another process, which produces gasoline from methanol, has been considered for commercialization. The government of New Zealand decided in December 1979 to build a commercial-size plant using its abundant natural gas as the feedstock in a natural gas to methanol to gasoline process. Because methanol can also be produced from gasified coal, this process may be an attractive option for the production of gasoline from coal in the United States. ...

1980-07-01

277

Synfuels from coal lessons: from South Africa  

Science.gov (United States)

The most significant lessons provided by these developments at SASOL are the importance of long-range planning and the need for establishing a commercialized technology base in synfuels. These are necessary to reduce our dependence on foreign energy sources and can be accomplished with suitable cooperation between government and private industry and between agencies within the government. The Fischer-Tropsch process is not the only method for producing gasoline from coal, but so far it is the only one commercially proven. Another process, which produces gasoline from methanol, has been considered for commercialization. The government of New Zealand decided in December 1979 to build a commercial-size plant using its abundant natural gas as the feedstock in a natural gas to methanol to gasoline process. Because methanol can also be produced from gasified coal, this process may be an attractive option for the production of gasoline from coal in the United States. ...

1980-07-01

278

The effects of pilot fuel quality on the ignition delay of gas fueled diesel engines  

Energy Technology Data Exchange (ETDEWEB)

The effects of changes in the cetane number of liquid pilot fuels on the ignition delay period in dual fuel engines were investigated experimentally. Various pilot fuel quantities were employed with methane, propane and low heating value gaseous fuel mixtures over a wide range of engine load.the ignition delay variation with increased gaseous fuel admission showed a strong dependence on both the quantity and the quality of the pilot fuel used. It was found that the use of high cetane number pilot liquid fuels permitted smaller pilot quantities to be used satisfactorily. Engine operation on propane and low heating value gaseous fuels improved in comparison with dual fuel engine operation employing common diesel fuels.

1997-07-01

279

Strontium-90 and cesium-137 in service water from June to December, 1981  

International Nuclear Information System (INIS)

Service water, 100 l each, was collected at an intake of a water treatment plant and at a tap after water was left running for five minutes. The carriers of strontium and cesium were added to water immediately after sampling, and the sample was vigorously stirred and filtered. Then it was passed through a cation exchange column at a rate of 80 ml/min. Strontium and cesium were eluted with hydrochloric acid from the cation exchange column, and separated. After the radiochemical separation, the mounted precipitates were counted for activity using low background beta counters normally for 60 min. Net sample counting rates were corrected for counter efficiency, recovery, self absorption and decay to obtain the content of strontium-90 and cesium-137 radioactivity per sample aliquot. From the results, concentrations of these nuclides in the original sample were calculated. The maximum ...

1981-12-01

280

Influence of suspended solids on pitting corrosion of carbon steel in cooling water. Tansoko no koshoku ni oyobosu reikyaku suichu no kendaku busshitsu no eikyo  

Energy Technology Data Exchange (ETDEWEB)

A large amount of industrial water is used for cooling the various process fluids in the petroleum purification factories as well as petroleum chemistry factories. Consequently, a lot of heat exchangers as the necessary constitutional instruments are made of carbon steel. Due to the most of the corrosions of the carbon steel occurring in such cooling water systems are pitting corrosions, the inhibition thereof is extremely important for the elongation of the life of the plants and the stable operation. In this paper, the influences of water quality fractions on pitting corrosion of carbon steel in cooling water circumstance are examined aiming at the fouling in the cooling water. The fouling in the cooling water does not only increase the amount of occurrence of pitting corrosion but also accelerates the progress of pitting corrosion ...

1993-08-15

281

Condensation driven water hammer studies for feed water distribution pipe  

International Nuclear Information System (INIS)

Special T-shaped feedwater distribution pipes were installed in steam generators at the Loviisa (Finland) and Rovno (Russia) nuclear power plants. The new shape was tested in an extensive testing programme. Since the tubes frequently suffer from corrosion damage, large-scale water hammer experiments were performed on a model facility in 1996. The main objectives of the water hammer experiments were to find out the prevailing parameters leading to water hammers, as well as the sensitivity of hammering to boundary conditions. A water hammer may occur when the mass flow rate into the steam generator exceeds 6 kg/s and the temperature difference between steam generator and feedwater exceeds 100 degC. Visual experiments and stress analyses of the pipe were also carried out. The weakest part, the T-joint, may hold against such water hammers only for a limited time of ...

1997-05-26

282

Off-gas behavior in the Harvest pot vitrification process  

Energy Technology Data Exchange (ETDEWEB)

The conversion of highly radioactive waste liquor into glass by the pot vitrification process has been studied at Harwell using a full-scale inactive pilot plant. A summary of the off-gas behavior and its interpretation is presented. Experimental runs were carried out on 3 representative wastes (MAGNOX - thermal reactor, metal fuel, THORP - thermal oxide fuel and PFR - fast reactor oxide fuel) using 2 methods of feeding the glass-formers (slurry and crizzle). Materials were carried over from the vitrification vessel into the off-gas system by entrainment supplemented by volatilization. The overall behavior of the off-gas was consistent with the presence in it of 5 separate aerosols of particulate matter. Sources of entrainment gave rise to 3 aerosols, and a further 2 aerosols were formed as a result of chemical reaction (Ru) and condensation (Cs) processes involving the volatile species. Entrainment was enhanced when the feed contained free ...

1983-06-01

283

Large dual-fuel engines with high efficiency and low environmental pollution  

Energy Technology Data Exchange (ETDEWEB)

This paper deals with the combustion process of the turbocharged dual-fuel engine with regard to improvement to thermal efficiency and exhaust gas emissions. It describes the method of charge-air control used to achieve optimal operation in either a pure diesel engine or a gas engine using the pilot-ignition process (dual-fuel principle). The change-over from gas to diesel operation and vice versa can be made automatically even under full load, i. e. the engine can be changed over from one mode of operation to the other without interruption. The exhaust gas constituents emitted by the dual-fuel engine are less detrimental to the environment than those of other internal-combustion engines: CO is hardly present at all; NOx is no higher than that from good diesel engines, or even lower; SO/sub 2/ does not occur since the natural gas, which is used most frequently, and the pilot fuel are practically free of sulfur; CH (hydrocarbons) in this case ...

1985-06-01

284

Anaerobic digestion as final step of a cellulosic ethanol biorefinery: Biogas production from fermentation effluent in a UASB reactor-pilot-scale results.  

Science.gov (United States)

In order to lower the costs for second generation bioethanol from lignocellulosic biomass anaerobic digestion of the effluent from ethanol fermentation was implemented using an upflow anaerobic sludge blanket (UASB) reactor system in a pilot-scale biorefinery plant. Both thermophilic (53 degrees C) and mesophilic (38 degrees C) operation of the UASB reactor was investigated. At an OLR of 3.5 kg-VS/(m(3) day) a methane yield of 340 L/kg-VS was achieved for thermophilic operation (53 degrees C) while 270 L/kg-VS was obtained under mesophilic conditions (38 degrees C). For loading rates higher than 5 kg-VS/(m(3) day) the methane yields were, however, higher under mesophilic conditions compared to thermophilic conditions. The conversion of dissolved organic matter (VS(diss)) was between 68% and 91%. The effluent from the ethanol fermentation showed no signs of toxicity to the anaerobic microorganisms. However, a high content of suspended matter ...

2010-09-01

285

Techno-economic investigation of an air humidification-dehumidification desalination process  

Energy Technology Data Exchange (ETDEWEB)

This article presents a humidification-dehumidification (H.D.) process suitable for desalination of sea- and brackish water. The work correlated performance characteristics of the combination of different components in such a loop. Water yield, energy requirement and design data are evaluated as functions of different parameters. The investigation covered water to air mass ratios ranging from 60 to 80, concentration ratios between 2 and 5, at a temperature difference of between 10 and 16 C, along the liquid for dehumidification. The results showed that 76% of energy consumed in the humidifier is recovered by condensation. Increase of the concentration ratio to 5 can reduce the make-up water and rejected brine by about 58% and 24% respectively. Cost calculations show that the H.D. process has significant potential as an alternative for small capacity desalination plants and permits ...

1993-08-01

286

Influence of O{sub 2} and N{sub 2}H{sub 4} on the ECP in high temperature water  

Energy Technology Data Exchange (ETDEWEB)

The ECP of construction materials in the water steam circuits of power plants is influenced by many parameters, including: reactions of oxidants, such as O{sub 2} or dissolved copper species; and reactions of reducing species, namely N{sub 2}H{sub 4}. Electrochemical measurements were performed to clarify the role of hydrazine for the open circuit potential in water/steam circuits. Current density electrode potential curves of the electrochemical oxidation of hydrazine and the reduction of oxygen in aqueous solutions were measured as a function of temperature in the range from room temperature to approximately 260{degrees}C. The electrode materials used were platinum, gold and Alloy 800 mod.. In addition, corrosion potentials were measured in water containing oxygen or hydrazine.

1992-12-31

287

Biomass production and relative competitiveness of a C3 legume and a C4 grass co-dominant in the semiarid Loess Plateau of China  

British Library Electronic Table of Contents (United Kingdom)

Bothriochloa ischaemum L. and Lespedeza davurica (Laxm.) Schindl. are two co-dominant species of great importance in reducing soil and water loss and maintaining the distinctive natural scenery of the semiarid Loess Plateau of China. Our aim was to determine the growth and interspecific competition between these species under water stress to facilitate the prediction of community succession and guide the selection of appropriate methods of conservation and use in the area. A pot experiment was designed to investigate the effects of water stress and competition on biomass production and allocation, relative competitive ability and water use efficiency of the two species. Bothriochloa ischaemum (a C4 perennial herbaceous grass) was planted in the same pot with L. davurica (a C3 perennial leg...

2011-01-01

288

Nuclear power plant support activities in reactors chemistry at CNEA  

International Nuclear Information System (INIS)

Argentina has two operating PHWR nuclear power plants. Atucha I NPP is a pressure vessel type heavy water reactor of 360 MW e with 25 years of operation and Embalse NPP is a pressure tube type CANDU-600 reactor of 640 MW e. Atucha II, a third plant of 600 MW e of the pressure vessel type similar to Atucha I, is being constructed. NASA (Nucleoelectrica Argentina S.A.) currently operates both nuclear power plants. The National Atomic Energy Commission (Comision Nacional de Energia Atomica - CNEA) provides operational support to the plants, including research and development assistance, and actual technical services and maintenance work in different areas. The Chemistry Department, formerly the Reactor Chemistry Department has carried out project and support activities to the plants during the past 20 years. The aim of this work is to describe the present ...

1999-10-15

289

The influence of salt aerosol on alpha radiation detection by WIPP continuous air monitors  

Energy Technology Data Exchange (ETDEWEB)

Alpha continuous air monitors (CAMs) will be used at the Waste Isolation Pilot Plant (WIPP) to measure airborne transuranic radioactivity that might be present in air exhaust or in work-place areas. WIPP CAMs are important to health and safety because they are used to alert workers to airborne radioactivity, to actuate air-effluent filtration systems, and to detect airborne radioactivity so that the radioactivity can be confined in a limited area. In 1993, the Environmental Evaluation Group (EEG) reported that CAM operational performance was affected by salt aerosol, and subsequently, the WIPP CAM design and usage were modified. In this report, operational data and current theories on aerosol collection were reviewed to determine CAM quantitative performance limitations. Since 1993, the overall CAM performance appears to have improved, but anomalous alpha spectra are present when sampling-filter salt deposits are at normal to high levels. This ...

1996-01-01

290

The Los Alamos National Laboratory Transuranic Waste Retireval Project  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the status of the Los Alamos National Laboratory (LANL) project for remediation of transuranic (TRU) and TRU mixed waste from Pads 1, 2, and 4. Some of the TRU waste packages retrieved from Pad I are anticipated to be part of LANL`s initial inventory to be shipped to the Waste Isolation Pilot Plant (WIPP) in April 1998. The TRU Waste Inspectable Storage Project (TWISP) was initiated in February 1993 in response to the New Mexico Environment Department`s (NMED`s) Consent Agreement for Compliance Order, ``New Mexico Hazardous Waste Agreement (NMHWA) 93-03.`` The TWISP involves the recovery of approximately 16,865 TRU and TRU-mixed waste containers currently under earthen cover on Pads 1, 2, and 4 at Technical Area 54, Area G, and placement of that waste into inspectable storage. All waste will be moved into inspectable storage by September 30, 2003. Waste recovery and storage operations emphasize protection of worker safety, ...

1997-02-01

291

TWR Bench-Scale Steam Reforming Demonstration  

Energy Technology Data Exchange (ETDEWEB)

The Idaho Nuclear Technology and Engineering Center (INTEC) was home to nuclear fuel reprocessing activities for decades at the Idaho National Engineering and Environmental Laboratory. As a result of the reprocessing activities, INTEC has accumulated approximately one million gallons of acidic, radioactive, sodium-bearing waste (SBW). The purpose of this demonstration was to investigate a reforming technology, offered by ThermoChem Waste Remediation, LLC, (TWR) for treatment of SBW into a "road ready" waste form that would meet the waste acceptance criteria for the Waste Isolation Pilot Plant (WIPP). TWR is the licensee of Manufacturing Technology Conservation International (MTCI) steam-reforming technology in the field of radioactive waste treatment. A non-radioactive simulated SBW was used based on the known composition of waste tank WM-180 at INTEC. Rhenium was included as a non-radioactive surrogate for technetium. Data was ...

2003-05-01

292

TWR Bench-Scale Steam Reforming Demonstration  

Energy Technology Data Exchange (ETDEWEB)

The Idaho Nuclear Technology and Engineering Center (INTEC) was home to nuclear fuel reprocessing activities for decades at the Idaho National Engineering and Environmental Laboratory. As a result of the reprocessing activities, INTEC has accumulated approximately one million gallons of acidic, radioactive, sodium-bearing waste (SBW). The purpose of this demonstration was to investigate a reforming technology, offered by ThermoChem Waste Remediation, LLC, (TWR) for treatment of SBW into a ''road ready'' waste form that would meet the waste acceptance criteria for the Waste Isolation Pilot Plant (WIPP). TWR is the licensee of Manufacturing Technology Conservation International (MTCI) steam-reforming technology in the field of radioactive waste treatment. A non-radioactive simulated SBW was used based on the known composition of waste tank WM-180 at INTEC. Rhenium was included as a non-radioactive surrogate for ...

2003-05-21

293

THOR Bench-Scale Steam Reforming Demonstration  

Energy Technology Data Exchange (ETDEWEB)

The Idaho Nuclear Technology and Engineering Center (INTEC) was home to nuclear fuel reprocessing activities for decades at the Idaho National Engineering and Environmental Laboratory. As a result of the reprocessing activities, INTEC has accumulated approximately one million gallons of acidic, radioactive, sodium-bearing waste (SBW). The purpose of this demonstration was to investigate a reforming technology, offered by THORsm Treatment Technologies, LLC, for treatment of SBW into a "road ready" waste form that would meet the waste acceptance criteria for the Waste Isolation Pilot Plant (WIPP). A non-radioactive simulated SBW was used based on the known composition of waste tank WM-180 at INTEC. Rhenium was included as a non-radioactive surrogate for technetium. Data was collected to determine the nature and characteristics of the product, the operability of the technology, the composition of the off-gases, and the fate of key ...

2003-05-01

294

THOR Bench-Scale Steam Reforming Demonstration  

Energy Technology Data Exchange (ETDEWEB)

The Idaho Nuclear Technology and Engineering Center (INTEC) was home to nuclear fuel reprocessing activities for decades at the Idaho National Engineering and Environmental Laboratory. As a result of the reprocessing activities, INTEC has accumulated approximately one million gallons of acidic, radioactive, sodium-bearing waste (SBW). The purpose of this demonstration was to investigate a reforming technology, offered by THORsm Treatment Technologies, LLC, for treatment of SBW into a ''road ready'' waste form that would meet the waste acceptance criteria for the Waste Isolation Pilot Plant (WIPP). A non-radioactive simulated SBW was used based on the known composition of waste tank WM-180 at INTEC. Rhenium was included as a non-radioactive surrogate for technetium. Data was collected to determine the nature and characteristics of the product, the operability of the technology, the composition of the ...

2003-05-21

295

Study on upgrading of oil palm wastes to animal feeds by radiation and fermentation processing  

International Nuclear Information System (INIS)

Upgrading of oil palm empty fruit bunch (EFB), which is a main by-product of palm oil industry, to animal feeds by radiation pasteurization and fermentation was investigated for recycling the agro-resources and reducing the environmental pollution. The following results were obtained: 1) The necessary dose for pasteurization of EFB contaminated by various microorganisms including aflatoxin producing fungi was determined as 10 kGy. The chemical and biological properties of EFB were changed little by irradiation up to 50 kGy. 2) In the fermentation process, Pleurotus sajor-caju was selected as the most effective fungi and the optimum condition for fermentation was clarified. The process of fermentation in suspension was also established for the liquid seed preparation. 3) The digestibility and nutritional value of fermented products were evaluated as ruminant animal feeds and the mushroom can be produced as by-product. 4) The pilot plant named ...

2002-10-15

296

Status of the WIPP Project  

Energy Technology Data Exchange (ETDEWEB)

The Waste Isolation Pilot Plant (WIPP), located in southeastern New Mexico, has been constructed to be a repository for transuranic (TRU) radioactive wastes generated from the US defense activities. In order to use WIPP as a repository for permanent disposal of TRU waste, the US Department of Energy (DOE) has to demonstrate compliance with the Standards for the Management and Disposal of Spent Nuclear Fuel, High Level and Transuranic Radioactive Wastes'' promulgated by the US Environmental Protection Agency (EPA) in the US Code of Federal Regulations 40 CFR Part 191. The DOE initially plans to perform experiments with a small quantity of waste at WIPP and would like to bring additional quantities for operational demonstration'', before determining whether WIPP is to be a repository for permanent disposal. There are serious problems in pursuing this course of action from an operational point of view. It would ...

1991-01-01

297

Red mud product development  

Energy Technology Data Exchange (ETDEWEB)

Kaiser Alumina and Chemical Co. impounds red mud, the byproduct of alumina production, behind levees. Kaiser recognizes that this action cannot be maintained indefinitely. Therefore, a project is in progress to produce useful products from red mud that increase the profitability of the Gramercy facility. Before products could be developed, an obstacle had to be overcome. The annual rainfall in South Louisiana prevents evaporative drying of the mud lakes. Innovative methods were applied to dry the lake mud. Two products have been developed. A daily landfill cover and an absorbant, which are marketed under the Cajunite{trademark} banner. Both products are currently being tested by potential customers at their sites. Environmental concerns were addressed during development. Extensive TCLP results show no metal leachate problems. All pilot tests and plant trials received LADEQ approval. Products that are under development include levee core, road ...

1996-10-01

298

Recent development in Mitsui B and W type gas injection diesel engine  

Energy Technology Data Exchange (ETDEWEB)

A gas injection diesel engine was developed as an approaching measure to the diversification of fuel. Contrary to the usual low pressure gas application engine, this engine applies a so-called diffuse combustion method, in which high pressure (24.7Mpa) gas fuel is injected directly in the cylinder and is ignited and combusted by a little pilot fuel injected almost at the same time. The engine have following features. As a principle, it can attain the same heat efficiency and output rate as a diesel engine in any load range. It is excellent in responsibility to load fluctuation. There is no internal leakage of gas fuel to the scavenging chamber (the crank chamber) in the compression stroke. Not only a wide range of mixed combustion of gas fuel and heavy oil fuel, but also single combustion of heavy oil is possible. It is, therefore, drawing attention as an engine for an LNG ship and also for a power generation plant with the recent increasing ...

1988-12-01

299

Process development for remote-handled mixed-waste treatment  

Energy Technology Data Exchange (ETDEWEB)

The Oak Ridge National Laboratory (ORNL) is developing a treatment process for remote-handled (RH) liquid transuranic mixed waste governed by the concept of minimizing the volume of waste requiring disposal. This task is to be accomplished by decontaminating the bulk components so the process effluent can be disposed with less risk and expense. Practical processes have been demonstrated on the laboratory scale for removing cesium 137 and strontium 90 isotopes from the waste, generating a concentrated waste volume, and rendering the bulk of the waste nearly radiation free for downstream processing. The process is projected to give decontamination factors of 10{sup 4} for cesium and 10{sup 3} for strontium. Because of the extent of decontamination, downstream processing will be contact handled. The transuranic, radioactive fraction of the mixed waste stream will be solidified using a thin-film evaporator and/or microwave solidification system. Resultant solidified waste will be disposed ...

1990-01-01

300

Positive pulsed corona discharge process for simultaneous removal of SO{sub 2} and NO{sub x} from iron-ore sintering flue gas  

Energy Technology Data Exchange (ETDEWEB)

The authors investigated the application of pulsed corona discharge process to the removal of SO{sub 2} and NO{sub x} from industrial flue gas of an ioron-ore sintering plant. This study was performed on a pilot scale, which is the most advanced demonstration of this process. The flow rate of 5000 m{sup 3}/h of the flue gas was successfully treated. The electrode structure of the corona reactor is the same with that of conventional electrostatic precipitator. The authors made use of magnetic pulse compression technology to produce repetitive high voltage pulse. Pulse width (full width at half maximum) was reduced to less than 1 {micro}s by connecting a resister in parallel with the corona reactor. An inductor was added to the resister in series to minimize the loss by restricting the current flowing through the resister. By this way, they were able to deliver pulse power with peak voltage of 110 kV and peak current of 2.3 kA to the corona ...

1999-08-01

301

Operation of pressurized internally circulating fluidized bed boiler (PICFB) 4MWth hot model  

Energy Technology Data Exchange (ETDEWEB)

In the atmospheric pressure coal combustion area, the Internally Circulating Fluidized Bed Boiler (ICFB) had already been proven to possess superior performance features in terms of the ease with which load conditions can be controlled and because of its low pollution level. Based on the particular merits of the ICFB furnace and the application of this technology to pressurized fluidized bed boiler technology, it was possible to achieve a pressurized fluidized bed boiler with superior ease of operation, reliability and low-pollution characteristics. From fiscal 1992, the authors have conducted extensive research work, including cold model tests and computer simulations to investigate the possibility of applying ICFB technology to the pressurized fluidized bed boiler technology in an attempt to develop the Pressurized Internally Circulating Fluidized Bed Boiler (PICFB). Based on the results achieved in this research, a hot-model design and fabrication project has been initiated in ...

1997-12-01

302

Neutron shielding and constructional characteristics of a new type concrete and from borated clinker  

International Nuclear Information System (INIS)

A boron containing cement, which can be used as nuclear shielding material, is produced at pilot plant scale applying two different methods. In the first method, the raw mixture of a normal portland cement is mixed with pre-calcined colemanite, a calcium borate mineral, and clinkerized in a rotary kiln (borated-clinker). In the second method, the colemanite is mixed with an admixture, which contains mainly limestone and marl, and burnt in the rotary kiln to obtain a borated-lime composite. The borated-lime composite is then added to the normal portland cement clinker up to 2% B_2O_3 content for shielding purpose. The results have shown that the borated-clinker contained untolerable amount of free lime resulting in a decrease in compressive strength. The addition of the borated-lime composite to the normal portland cement clinker up to 1% B_2O_3 content did not alter the setting time and the volume expansion properties. The reduction in the ...

1994-11-07

303

Improving the scheme for final comminution of the coal charge  

Science.gov (United States)

Proceeding from laboratory and pilot plant tests of the screening of fine classes of coal under the effect of gravitational forces on stationary grates, and also from the experience of the Krivoi Rog and Kommunarsk Coke Works (1,2), the coal preparation division of OKhMK (Orsk-Khalilovo Integrated Iron and Steel Works) adopted an industrial scheme of comminution of coal before coking, screening out the fine classes ahead of the hammer crushers. In the bottom of the feeder chute a stamped screen was installed (dimensions 2100 X 1600 X 5 mm with apertures of 40 X 100 mm) with the large side perpendicular to the flow of coal. The distance between the apertures on the small side of the screen was 20 mm, on the large side 15 mm; the inclination was 60/sup 0/. The overscreen product enters the crusher, and the underscreen product is injected into the crushed charge without comminution. The improvement in the uniformity of the granulometric and ...

1983-01-01

304

Gramineae gasification project (Pennisetum purpureum); Projeto gaseificacao de graminea (Pennisetum purpureum)  

Energy Technology Data Exchange (ETDEWEB)

This study is part of a greater project from IPT (Sao Paulo's Institute of Technology), which foresaw an energetic use for elephant-grass (Pennisetum purpureum). Biomass gasification is an sustainable option for energy supply, which presents low pollutants emission rate and allows - through the global cycle of growing and consumption of feedstock (vegetables), a balance between consumption and production of carbonic gas, preventing an increase of the carbonic gas levels in the atmosphere. A gasifier was built with internal diameter of 400 mm and total height of 4600 mm . The equipment was tested for gasification of elephant-grass (Pennisetum purpureum) at a 100 kg/h rate. The equipment was tested and some constructive faults were detected. In the countryside, this biomass is commonly used for cattle feeding It was evaluated an adequate diesel-electric-generator. to work at hybrid regime, using 70% biomass gas and 30% diesel. With the equipment's construction costs, ...

2000-07-01

305

GENERIC ENZYME TECHNOLOGY FOR IMPROVED PAPER RECYCLING  

Environmental Research Database

Objectives- Investigate the potential for the use of enzymes to bring about improvements in the recycling of recovered waste paper sources~%~~%~- Optimise enzyme formulations and process conditions to maximise benefits. - Produce recovered fibre at lower energy and chemical costs than is currently achievable using 'classical' de-inking techniques.~%~~%~- Improve recycled fibre quality and~%~~%~- All of the above will allow a greater use of recovered paper resources, which would otherwise be diposed of by [continued...]DescriptionThe project proposes to carry out an initial literature review to update the consortium on the currently available publications relating to the use of enzymes in de-inking.. This will be followed by an intensive laboratory study in an upgraded facility which will allow enzyme formulations and mechanisms to be studied. This work will also eliminate the need for an initial round of pilot ...

2003-01-05

306

Fundamental investigation of duct/ESP phenomena  

Energy Technology Data Exchange (ETDEWEB)

This report describes in detail the First Generation Duct Injection Model developed for the analysis of the fundamental processes of flue gas desulfurization by sorbent injection. The model is a two- and three-dimensional, multiphase reacting flow analyzer using computational fluid dynamics methods. The gaseous phase is solved in an Eulerian frame while the droplets or particles are tracked in a Lagrangian frame. The model has an associated preprocessor which allow easy problem set up by the use without in-depth knowledge of computational fluid dynamics. The aerodynamics of the First Generation Duct Injection Model have been successfully validated with a number of test cases for which experimental data are available. Data from the Meredosia pilot plant humidification tests have been used to validate the gas and droplet dynamics of the model with good agreement. Comparison of SO{sub 2} removal results using the present model (with one injector) ...

1990-12-01

307

From waste minimization to ISO 14000: Taiwan`s experience and prospects  

Energy Technology Data Exchange (ETDEWEB)

Taiwan has completed a very successful five-year industrial waste minimization (IWM) demonstration and promotion project sponsored by the government. From 1990 to 1995, the project successfully disseminated the IWM concept of pollution prevention (P2) to industries. It effectively reduced industrial waste while significantly benefitting the economy by assisting industries in implementing in-plant IWM programs. In July 1995, the second stage of the five-year IWM and ISO 14000 promotion project was initiated for further promoting the IWM, P2, and cleaner production and, in particular, coping with the upcoming international environmental management standards (ISO 14000). To assist industries in establishing an environmental management system (EMS) and accumulating related experience, an EMS pilot demonstration project of five model industries and an ISO 14001 EMS demonstration and promotion project for 22 factories in 13 industries were initiated ...

1996-12-31

308

Externally fired combined cycle demonstration  

Energy Technology Data Exchange (ETDEWEB)

Externally Fired Combined Cycles (EFCCs) can increase the amount of electricity produced from ash bearing fuels up to 40%, with overall powerplant efficiencies in excess of 45%. Achieving such high efficiencies requires high temperature-high pressure air heaters capable of driving modern gas turbines from gas streams containing the products of coal combustion. A pilot plant has been constructed in Kennebunk, Maine to provide proof of concept and evaluation of system components. Tests using pulverized Western Pennsylvania bituminous coal have been carried out since April, 1995. The ceramic air heater extracts energy from the products of coal combustion to power a gas turbine. This air heater has operated at gas inlet temperatures over 1,095 C and pressures over 7.0 atm without damage to the ceramic tube string components. Stable gas turbine operation has been achieved with energy input from the air heater and a supplementary gas fired combustor. ...

1995-11-01

309

Effect of the steam explosion pretreatment on enzymatic hydrolysis of eucalyptus wood and sweet sorghum baggages; Efecto del pretratamiento con explosion por vapor en la hidrolisis enzimatica de madera de eucalipto y bagazo de sorgo  

Energy Technology Data Exchange (ETDEWEB)

The effect of steam explosion treatment on the enzymatic hydrolysis yield of two different lignocellulosic substrates is studied. Raw materials have been pretreated in a pilot plant designed to work in batch and equipped with a reactor vessel of 2 1 working volume where biomass was heated at the desired temperature and then exploded and recovered in a cyclone. Temperatures from 190 to 230 degree celsius and reaction times from 2 to 8 min. have been assayed. The efficiency of the steam explosion treatment has been evaluated on the composition of the lignocellulosic materials as well as on their enzymatic hydrolysis yield using a cellulolytic complex from T. reesel. Results show a high solubilization rate of hemicelluloses and variable losses of cellulose and lignin depending on the conditions tested. Enzymatic hydrolysis yields of both substrates experimented remarkable increments, corresponding the highest values obtained to 210 degree celsius; ...

1991-07-01

310

Effect of primary air content on formation of nitrogen oxides during combustion of Ehkibastuz coal  

Energy Technology Data Exchange (ETDEWEB)

Investigations are discussed carried out in a pilot plant at the Kaz. Power Engineering Scientific Research Institute into the effect of the amount of primary air in coal-dust flame on the final concentration of nitrogen oxides in flue gases. The tests were carried out in a 7500 mm high, 1600 mm dia vertical cylindrical combustion chamber having type P-57 burner, and air dispersed fuel plus additional air supplies located at the top. Amounts of coal dust fed by a drum feeder along the air pipe varied from 100-600 kg/h. The required air was supplied by 5000 m/sup 3//h Type TK-700/5 blowers at 0.04 MPa. Ehkibastuz coal samples contained: 1.3% moisture; 48.1% ash; 38.02% carbon; 2.56% hydrogen; 0.73% sulfur; 0.60% nitrogen; heat of combustion was 14.3 MJ/kg. Results obtained indicate that variations in the amount of primary air in swirl flow burners affect formation of fuel nitrogen; there is an optimum volume at which minimum quantities of ...

1986-01-01

311

Dissolution Kinetics of Zirconia Calcine  

International Nuclear Information System (INIS)

Liquid radioactive raffinates from nuclear fuel reprocessing at the Idaho National Engineering and Environmental Laboratory were solidified, or calcines, in a fluidized bed reactor at approximately 500 C to form a dry granular material. This calcine has been provisionally stored near-surface in concrete-encased stainless steel bins at the Idaho Nuclear Technology Engineering Center. Research addressing the permanent immobilization of radioactive waste has been ongoing. One option is to separate the radioactive constituents from the calcine, thereby reducing the radioactive waste volume to be ultimately stored at a national nuclear waste repository. Nitric acid dissolution of the calcine is a key front-end unit operation in the separations option. In order to design calcine dissolution equipment, quantification of dissolution reaction rate parameters is required. A pilot-plant-produced, non-radioactive calcine was utilized to study the dissolution kinetics of a ...

312

Disposal of spent fuel from German nuclear power plants - paper work or technology?  

International Nuclear Information System (INIS)

The reference concept 'direct disposal of spent fuel' was developed as an alternative to spent fuel reprocessing and vitrified HLW disposal. The technical facilities necessary for the implementation of this reference concept - the so called POLLUX-concept, e.g. interim storages for casks containing spent fuel, a pilot conditioning facility, and a special cask 'POLLUX' for final disposal have been built. With view to a geological salt formation all handling procedures for the repository were tested aboveground in a test facility at a 1:1 scale. To optimise the concept all operational steps are reviewed for possible improvement. Most promising are a concept using canisters (BSK 3) instead of POLLUX casks, and the direct disposal of transport and storage casks (DIREGT-concept) which is the most recent one and has been designed for the direct disposal of large transport and storage casks. The final exploration of the pre-selected repository site is still pending, from ...

2006-09-17

313

Direct hydrogenation and solvent extraction of coal. [US DOE  

Science.gov (United States)

Recent fuel cost increases coupled with energy shortages have resulted in an awareness of the need to conserve energy and to expand the United States domestic energy base. Increase in coal conversion and utilization are major objectives of the research and development activities in the US Department of Energy. Several alternate processing schemes are being developed to convert coal to environmentally acceptable liquid fuels. A few of these technologies are approaching the commercialization stage and scale-up is being carried forward on the most promising processes. The various coal liquefaction processes are discussed by dividing them into four general classifications. Processes for converting various types of coal to synthetic liquid fuels are being improved so that clean fuels can be produced commercially. Emphasis is on the production of fuels suitable for firing industrial and electric utility boilers and on synthetic crude oils for upgrading to liquids for use in transportation ...

1979-09-01

314

Design/build/mockup of the Waste Isolation Pilot Plant gas generation experiment glovebox  

Energy Technology Data Exchange (ETDEWEB)

A glovebox was designed, fabricated, and mocked-up for the WIPP Gas Generation Experiments (GGE) being conducted at ANL-W. GGE will determine the gas generation rates from materials in contact handled transuranic waste at likely long term repository temperature and pressure conditions. Since the customer`s schedule did not permit time for performing R&D of the support systems, designing the glovebox, and fabricating the glovebox in a serial fashion, a parallel approach was undertaken. As R&D of the sampling system and other support systems was initiated, a specification was written concurrently for contracting a manufacturer to design and build the glovebox and support equipment. The contractor understood that the R&D being performed at ANL-W would add additional functional requirements to the glovebox design. Initially, the contractor had sufficient information to design the glovebox shell. Once the shell design was approved, ANL-W built a full scale mockup of the shell ...

1996-10-01

315

Crushed Salt Constitutive Model  

Energy Technology Data Exchange (ETDEWEB)

The constitutive model used to describe the deformation of crushed salt is presented in this report. Two mechanisms -- dislocation creep and grain boundary diffusional pressure solution -- are combined to form the basis for the constitutive model governing the deformation of crushed salt. The constitutive model is generalized to represent three-dimensional states of stress. Upon complete consolidation, the crushed-salt model reproduces the Multimechanism Deformation (M-D) model typically used for the Waste Isolation Pilot Plant (WIPP) host geological formation salt. New shear consolidation tests are combined with an existing database that includes hydrostatic consolidation and shear consolidation tests conducted on WIPP and southeastern New Mexico salt. Nonlinear least-squares model fitting to the database produced two sets of material parameter values for the model -- one for the shear consolidation tests and one for a combination of the shear ...

1999-02-01

316

Coal liquefaction. Quarterly report, April-June 1979  

Science.gov (United States)

DOE's program for the conversion of coal to liquid fuels was begun by two of DOE's predecessor agencies: Office of Coal Research (OCR) in 1962, and Bureau of Mines, US Department of the Interior, in the 1930's. Current work is aimed at improved process configurations for both catalytic and non-catalytic processes to provide more attractive processing economics and lower capital investment. The advantage of coal liquefaction is that the entire range of liquid products, especially boiler fuel, distillate fuel oil, and gasoline, can be produced from coal by varying the type of process and operating conditions used in the process. Furthermore, coal-derived liquids have the potential for use as chemical feedstocks. To provide efficient and practical means of utilizing coal resources, DOE is supporting the development of several conversion processes that are currently in the pilot plant stage. DOE, together with the ...

1980-04-01

317

Chevron STB oil shale retort  

Energy Technology Data Exchange (ETDEWEB)

Factors important in choosing between process concepts were mechanical complexity and amenability to scale-up studies. The culmination of this work was a process concept known as Staged Turbulent Bed Retorting Process (STB), which has now been tested in pilot plants. Operating conditions are described. The environment in the retort section can be described as a staged, moving bed of particles, in which a portion of the particles are fluidized at gas velocities well below minimum fluidization velocity of many of the particles. Research and engineering evaluations have established that the STB provides prospects for the responsible development of oil shale resources on a commercial scale. A 320 ton/d semiworks unit, the next technological step, will be commissioned shortly. This unit will be large enough to provide scale-up data for design of modules and to demonstrate the entire process, generating data needed to optimize, design, and construct ...

1982-03-01

318

Catalytic activity of pyrite for coal liquefaction reaction; Tennen pyrite no shokubai seino ni kansuru kento  

Energy Technology Data Exchange (ETDEWEB)

Since natural pyrite is easy to obtain and cheap as coal liquefaction catalyst, it is to be used for the 150 t/d scale NEDOL process bituminous coal liquefaction pilot plant. NEDO and NCOL have investigated the improvement of catalytic activity of pulverized natural pyrite for enhancing performance and economy of the NEDOL process. In this study, coal liquefaction tests were conducted using natural pyrite catalyst pulverized by dry-type bowl mill under nitrogen atmosphere. Mechanism of catalytic reaction of the natural pyrite was discussed from relations between properties of the catalyst and liquefaction product. The natural pyrite provided an activity to transfer gaseous hydrogen into the liquefaction product. It was considered that pulverized pyrite promotes the hydrogenation reaction of asphaltene because pulverization increases its contact rate with reactant and the amount of active points on its surface. It was inferred that catalytic ...

1996-10-28

319

CO2 Capture by Absorption with Potassium Carbonate  

Energy Technology Data Exchange (ETDEWEB)

The objective of this work is to improve the process for CO{sub 2} capture by alkanolamine absorption/stripping by developing an alternative solvent, aqueous K{sub 2}CO{sub 3} promoted by piperazine. In Campaign 3 of the pilot plant, the overall mass transfer coefficient for the stripper with 7 m MEA decreased from 0.06 to 0.01 mol/(m{sup 3}.s.kPa) as the rich loading increased from 0.45 to 0.6 mol CO{sub 2}/mol MEA. Anion chromatography has demonstrated that nitrate and nitrite are major degradation products of MEA and PZ with pure oxygen. In measurements with the high temperature FTIR in 7 m MEA the MEA vapor pressure varied from 2 to 20 Pa at 35 to 70 C. In 2.5 m PZ the PZ vapor pressure varied from 0.2 to 1 Pa from 37 to 70 C.

2005-01-26

320

A simple model for strontium breakthrough on zeolite columns  

Science.gov (United States)

The Process Waste Treatment Plant (PWTP) at the Oak Ridge National Laboratory is designed to remove radioactive contaminants, principally {sup 90}Sr, from process wastewater. Planned upgrades to the PWTP will use chabazite zeolite columns. Pilot-scale studies have shown that mass transfer zone lengths increase from 10 to about 30 cm as the superficial velocity increases from 5.5 to 22 cm/min. Calculations with a multicomponent equilibrium model showed that the distribution coefficient for strontium remains essentially constant over the process conditions, suggesting that a simple kinetic model (the Rosen long-bed solution) should adequately represent breakthrough behavior. Using a distribution coefficient of 4.87 L/g predicted by the equilibrium model, good agreement was found between experimental breakthrough curves and those calculated with the Rosen solution. This model allows prediction of bed depths and cycle times necessary to achieve the ...

1995-04-01

321

Staged direct injection diesel engine  

Energy Technology Data Exchange (ETDEWEB)

A diesel engine having staged injection for using lower cetane number fuels than No. 2 diesel fuel. The engine includes a main fuel injector and a pilot fuel injector. Pilot and main fuel may be the same fuel. The pilot injector injects from five to fifteen percent of the total fuel at timings from 20.degree. to 180.degree. BTDC depending upon the quantity of pilot fuel injected, the fuel cetane number and speed and load. The pilot fuel injector is directed toward the centerline of the diesel cylinder and at an angle toward the top of the piston, avoiding the walls of the cylinder. Stratification of the early injected pilot fuel is needed to reduce the fuel-air mixing rate, prevent loss of pilot fuel to quench zones, and keep the fuel-air mixture from becoming too fuel lean to become effective. In one embodiment, the ...

1985-01-01

322

Law project adopted by the Senate and authorizing the ratification of the additional protocol to the agreement between France, the European atomic energy community and the international atomic energy agency relative to the application of warranties in France; Projet de loi adopte par le Senat autorisant la ratification du protocole additionnel a l'accord entre la France, la Communaute europeenne de l'energie atomique et l'Agence internationale de l'energie atomique relatif a l'application de garanties en Franc  

Energy Technology Data Exchange (ETDEWEB)

This project of law concerns an additional protocol to the agreement of warranties signed on September 22, 1998 between France, the European atomic energy community and the IAEA. This agreement concerns the declaration of all information relative to the R and D activities linked with the fuel cycle and involving the cooperation with a foreign country non endowed with nuclear weapons. These information include the trade and processing of nuclear and non-nuclear materials and equipments devoted to nuclear reactors (pressure vessels, fuel loading/unloading systems, control rods, force and zirconium tubes, primary coolant pumps, deuterium and heavy water, nuclear-grade graphite), to fuel reprocessing plants, to isotope separation plants (gaseous diffusion, laser enrichment, plasma separation, electromagnetic enrichment), to heavy water and deuterium production plants, and to uranium ...

2002-10-01

323

Process development for production of coal/sorbent agglomerates. Final technical report, September 1, 1990--August 31, 1991  

Energy Technology Data Exchange (ETDEWEB)

The goal of this work was to develop a process flow diagram to economically produce a clean-burning fuel from fine Illinois coal. To accomplish this, the process of pelletizing fine coal with calcium hydroxide, a sulfur capturing sorbent, was investigated. Carbonation, which is the reaction of calcium hydroxide with carbon dioxide (in the presence of moisture) to produce a bonding matrix of calcium carbonate, was investigated as a method for improving pellet quality and reducing binder costs. Proper moisture level is critical to allow the reaction to occur. If too much moisture is present in a pellet, the pore spaces are filled and carbon dioxide must diffuse through the water to reach the calcium hydroxide and react. This severely slows or stops the reaction. The ideal situation is when there is just enough moisture to coat the calcium hydroxide allowing for the reaction to proceed. The process has been successfully demonstrated on a ...

1991-12-31

324

Phosphorous adsorption and precipitation in a permeable reactive wall: Applications for wastewater disposal systems  

Energy Technology Data Exchange (ETDEWEB)

A permeable reactive mixture has been developed using low cost, readily available materials that is capable of providing effective, long-term phosphorous treatment in areas impacted by on-land wastewater disposal. The reactive mixture creates a geochemical environment suitable for P-attenuation by both adsorption and precipitation reactions. Potential benefits include significant reductions in phosphorous loading to receiving groundwater and surface water systems, and the accumulation of P-mass in a finite and accessible volume of material. The mixture may be applied as a component within surface treatment systems or in subsurface applications such as horizontal or vertical permeable reactive walls. The mixture averaged > 90% treatment efficiency over 3.6 years of continuous-flow laboratory column experiments. The mixture was further evaluated at the pilot-scale to treat municipal wastewater, and the field-scale to treat a well-characterized ...

1997-12-31

325

Flue gas desulfurization pilot study. phase i. survey of major installations. report no. 95. summary of survey reports on flue gas desulfurization processes  

Science.gov (United States)

Appendices to this summary consist of twelve individual status reports that will be available through the National Technical Information Service (NTIS) in the United States and of course limited copies will be available through NATO. The twelve report titles which are appendices to the summary are: (A) Status Report on the Limestone/Sludge Flue Gas Desulfurization Process; (B) Status Report on the Lime/Sludge Flue Gas Desulfurization Process; (C) Status Report on the Double Alkali/Sludge Flue Gas Desulfurization Process; (D) Status Report on the Sea Water Scrubbing Flue Gas Desulfurization Process; (E) Status Report on the Limestone/Gypsum Flue Gas Desulfurization Process; (F) Status Report on the Lime/Gypsum Flue Gas Desulfurization Process; (G) Status Report on the Double Alkali/Gypsum Flue Gas Desulfurization Process; (H) Status Report on Flue Gas Desulfurization by Scrubbing with Dilute Sulfuric Acid; (I) Status Report on the Magnesium Oxide Flue Gas ...

1979-01-01

326

Biodrying of animal slaughterhouse residues and heat production  

Energy Technology Data Exchange (ETDEWEB)

Animal carcasses from slaughterhouses are usually composted on farms, but the composting process is not optimized and a large volumes of carbonaceous residues are needed. This type of composting takes place over a period of 6 to 9 months in a nonaerated static pile. Quebec's industrial research centre (CRIQ) developed an organic biodrying process (BIOSECO) adapted to large-scale operations in order to optimize the treatment of slaughterhouse residues. Biodrying is a form of composting, in which the thermophilic phase is optimized, making it possible to evaporate large amounts of water. Biodrying is done inside a building and reduces the amount of carbonaceous residues considerably. The process is optimized by the sequence in which the slaughterhouse residues are added, the choice of input and the aeration flow. Slaughterhouse residues can be treated non-stop throughout the entire year. Since the odours are nearly completed limited to the building, the ...

2010-07-01

327

A modeling and experimental study of flue gas desulfurization in a dense phase tower.  

Science.gov (United States)

We used a dense phase tower as the reactor in a novel semi-dry flue gas desulfurization process to achieve a high desulfurization efficiency of over 95% when the Ca/S molar ratio reaches 1.3. Pilot-scale experiments were conducted for choosing the parameters of the full-scale reactor. Results show that with an increase in the flue gas flow rate the rate of the pressure drop in the dense phase tower also increases, however, the rate of the temperature drop decreases in the non-load hot gas. We chose a water flow rate of 0.6 kg/min to minimize the approach to adiabatic saturation temperature difference and maximize the desulfurization efficiency. To study the flue gas characteristics under different processing parameters, we simulated the desulfurization process in the reactor. The simulated data matched very well with the experimental data. We also found that with an increase in the Ca/S molar ratio, the differences between the simulation and ...

2011-03-05

328

2008 Data Report: Groundwater Monitoring Program Area 5 Radioactive Waste Management Site  

Science.gov (United States)

This report is a compilation of the groundwater sampling results from the Area 5 Radioactive Waste Management Site (RWMS) including calendar year 2008 results. Each of the three Pilot Wells was sampled on March 11, 2008, and September 10, 2008. These wells were sampled for the following indicators of contamination: pH, specific conductance, total organic carbon, total organic halides, and tritium. Indicators of general water chemistry (cations and anions) were also monitored. Results from all samples collected in 2008 were within the limits established by agreement with the Nevada Division of Environmental Protection for each analyte. These data indicate that there has been no measurable impact to the uppermost aquifer from the Area 5 RWMS. There were no significant changes in measured groundwater parameters compared to previous years. Other information in the report includes an updated Cumulative Chronology for the Area 5 RWMS Groundwater ...

2009-01-13

329

2006 Data Report: Groundwater Monitoring Program Area 5 Radioactive Waste Management Site  

Science.gov (United States)

This report is a compilation of the groundwater sampling results from the Area 5 Radioactive Waste Management Site (RWMS) for calendar year 2006. Pilot wells UE5PW-1, UE5PW-2, and UE5PW-3 were sampled in April and October 2006 for the following indicators of contamination: pH, specific conductance, total organic carbon, total organic halides, and tritium. Indicators of general water chemistry (cations and anions) were also monitored. Results from all samples collected in 2006 were within the limits established by agreement with the Nevada Division of Environmental Protection for each analyte. These data indicate that there has been no measurable impact to the uppermost aquifer from the Area 5 RWMS. There were no significant changes in measured groundwater parameters compared to previous years. Other information in the report includes an updated Cumulative Chronology for the Area 5 RWMS Groundwater Monitoring Program and a brief description of ...

2007-02-01

330

Anthropogenic materials and products containing natural radionuclides. Pt. 2a. Investigation of occupational radiation doses. Specific and long-term measurements in a drinking-water conditioning plant; Anthropogene Stoffe und Produkte mit natuerlichen Radionukliden. T. 2a. Untersuchungen zur Strahlenexposition beim beruflichen Umgang. Detail- und Langzeitmessungen in einer Trinkwasseraufbereitungsanlage  

Energy Technology Data Exchange (ETDEWEB)

The measuring series was performed from November 1991 through April 1992 in seven drinking-water conditioning plants of the Fichtel mountains area in the north-eastern part of Bavaria, and the results revealed as an annual average a dose of about 1 - 40 WLM. The area of interest is a drinking-water catchment area where the ground water and other water resources include waters particularly rich in radon content, which explains this relatively high dose range. This is why comprehensive, specific local and long-term mearurements were carried out in order to assess the occupational radiation dose in the drinking-water conditioning plants, taking as a model site the conditioning plant of the municipal utilities of Hof in Weissenstadt. These more specific measurements were performed by the Technical ...

1995-03-01

331

Improved primary water chemistry control of PWR plant in Japan  

International Nuclear Information System (INIS)

Elevated pH operation to the pH value of 7.3 at 285degC is known to be effective for the reduction of radiation source in the primary water system of PWRs. A research project was started in 1989 and concluded in 1996 to study and verify the optimum pH and/or Li concentration from the viewpoint of radiation source reduction and materials integrity under improved water chemistry. This research project is sponsored by the Ministry of International Trade and Industries (MITI) in Japan and has two programs; high pH and high Li. The high Li program was conducted to establish the optimum Li concentration for the high boron concentration region (1100 - 1800 ppm) of the high burn up operation. In this paper, we shall discuss radiation source behavior under high pH conditions and PWSCC (Primary Water Stress Corrosion Cracking) susceptibility of materials with change of primary water chemistry conditions and the ...

1998-04-01

332

Examination of thermally polluted water for free living amoebae and testing for their possible pathogenic properties  

Energy Technology Data Exchange (ETDEWEB)

Water and mud samples were collected from canals and rivers which were adjacent to outlets discharging warm water of 3 power plants in Berlin. Downstream samples from 1 bathing resort were also collected. Free living amoebae were isolated from 138 water and 69 mud samples. From these respectively 156 and 73 strains could be cultured and were administered intranasally to mice for pathogenicity tests. Two Acanthamoeba strains from water and 7 from mud could be reisolated from mouse brain and or lungs, although no pathological disorders could be observed. Five Naegleria strains were negative in mouse inoculation tests. Four Acanthamoeba strains which were positive in mice were cultured at + 45 degrees C; no cytopathogenic effects were observed in tissue cultures. Acanthamoeba infective for mice could also be isolated from samples at low water temperatures. Further ...

1982-05-01

333

Development of a new tool for predicting water quality. Verification on a stretch of the river Ebro; Desarrollo de una nueva herramienta para la prediccion de la calidad del agua. Verificacion en un tramo del rio Ebro  

Energy Technology Data Exchange (ETDEWEB)

The Water Frame work Directive (December 2000) proposes integrated water management in regard to both quality and quality. A mathematical model has therefore been produced at the CEIT and EPTISA research centre, in collaboration with the Ebro Hydrographic. Confederation (CHE), to predict water quality and thus begin integrated management of it in the river basins. A description is given of the characteristics of the simulation tool. The hydraulic model is based on the numerical (weighted, four-point implicit) resolution of the complete Saint Venant equations. The quality model is based on the IWA River Water Quality Model Number 1 which has clear advantages (consistency, mass balance and easy integration with the biological models of the waste water treatment plants and the collector networks compared to traditional models. The experimental validation, which ...

2004-07-01

334

Experimental and theoretical studies on humidification-dehumidification-desalination  

Energy Technology Data Exchange (ETDEWEB)

The shortage of fresh water is increasing at alarming levels, even in temperate zones. Desalination of brackish and seawater is being considered as a solution to growing water demands. Seawater desalination can be accomplished through reverse osmosis, vapor compression, vapor absorption and thermally driven systems. The most suitable process for large-scale desalination plants is successive brine evaporation-condensation with intermediate heat recovery. However, higher process efficiency could be achieved. The use of low temperature heat sources in seawater desalination requires an efficient method of evaporation and condensation at relatively low vapor pressures. This could be achieved in a humidification-dehumidification process using circulated air to enhance evaporation of water. Simulation models, however, neglect either the heat of evaporation or the changes in air and water ...

2006-07-01

335

Determination of the minor disinfection by-products formed in the water plant of Sant Joan Despi (Barcelona, Spain); Determinacion de los subproductos de desinfeccion minoritarios formados en la planta de Sant Joan Despi (Barcelona)  

Energy Technology Data Exchange (ETDEWEB)

Chlorine is widely used in drinking water disinfection due to be a powerful and not expense disinfection. Although the benefits of disinfection, the formation of stable disinfection by-products of the health concern, is the result of the interaction of aqueous chlorine with natural organic matter presents in water. Disinfection by-products generated in major concentration are trihalomethane and haloacetic acids. Disinfection by-products generated in minor concentration are haloacetonitriles, haloketones,chloral hydrate and chloropicrin and some new groups such as cyanogen halides and trihaloacetaldydes. In this work two analytical methods.: headspace/gas chromatography/electron capture detector and liquid-liquid microextraction/gas chromatography/electron capture detector are studied and compared to determine the minor by-products and to establish finally, a systematic control of them in the different stages of the Water ...

1997-09-01

336

UK's Sizewell inquiry; funny how time slips away  

Energy Technology Data Exchange (ETDEWEB)

Comments are made on the Public Inquiry into CEGB's proposal to construct a pressurized water reactor (PWR) at Sizewell, UK. Aspects discussed include: time elapsed and its possible effect on the result; economics of nuclear power plants compared with coal-fired power plants; changes in real sterling/dollar exchange rates; effect of mineworkers' strike; the UK electric power generating system; AGR reactors compared with PWR reactors; extension of Magnox reactor life; radioactive waste management; political decisions.

1985-03-01

337

Relining of scrubbers in flue gas desulfurization plants  

Science.gov (United States)

Rubber lining is used as a corrosion protection material in European flue gas desulfurization plants, for scrubbers, tanks, pipe systems, etc. Although these rubber linings can last more than 15 years, relining still is necessary. The difficulty of shutting down power station units requires that the time scale of this replacement be kept to a minimum. High-pressure water systems have proven successful as an efficient method for removal of the old lining. The working steps and time scale are demonstrated for one such relining case.

1999-09-01

338

Inter-comparison of some environmental radioactivity monitoring items for Guangdong Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

This paper introduces the inter-comparison results of some environmental radioactivity monitoring items for Daya Bay nuclear power plant. The inter-comparison was organized by China Institute for Radiation Protection and five laboratories participated in it. The compared items included total #beta# in kelp and sediment, "3H in water, "9"0Sr in soil, artificial nuclides "1"1"0"mAg, "2"4"1Am, "1"0"9Cd, "5"7Co in kelp and sediment. Inter-comparison results are analyzed as well

2003-01-01

339

Improvement of FLOWER code and its application in Daya Bay  

International Nuclear Information System (INIS)

FLOWER, a computer code recommended by USNRC for assessing the environmental impact in tidal regions, was adapted and improved so as to be suitable to deal with the influence of drift stream along seashore to the dilution of contaminants and heat in the bay mouth. And the code outputs were presented with more mid-results such as average concentrations and temperature values for all tides considered. Finally, the modified code is applied to the dispersion calculation of heat and liquid effluents from Daya Bay Nuclear Power Plant, and the impacts from routine operation of the plant on Daya Bay sea waters were given.

340

Dynamics of the controlled environment conditions in SVET greenhouse in flight  

Energy Technology Data Exchange (ETDEWEB)

The dynamics of the controlled environment conditions in the SVET-4 space greenhouse model were investigated, using computerized equipment to continuously measure and collect the values of the inside environment parameters, which were then sent to earth. The on-ground analysis of telemetric data for the first 29 days indicated that radishes and the Chinese cabbage plants planted in SVET-4 grew under normal temperature conditions, but in insufficient substrate moisture. After supplying the necessary quantity of water, the analysis of the first 54 days of experiment is continuing. 2 refs.

1992-01-01

341

Development of safety function assessment trees for pressurized heavy water reactor LP/SD operations  

Energy Technology Data Exchange (ETDEWEB)

The objective of Configuration Risk Management Program(CRMP) is to maintain the safety level by assuring the defense-in-depth of nuclear power plant while the configurations are changed during plant operations, especially for the LP/SD. Such a safety purpose can be achieved by establishing the risk monitoring programs with both quantitative and qualitative features. Generally, the quantitative risk evaluation models, i.e., PRA models are used for the risk evaluation during full power operation, and the qualitative risk evaluation models such as safety function assessment trees are used. Through this study, safety function assessment trees were developed.

2003-10-01

342

Instrumentation for monitoring and control of cycle chemistry for the steam-water circuits of fossil-fired and combined-cycle power plants  

Energy Technology Data Exchange (ETDEWEB)

A guidance document on the instrumentation for monitoring and control of cycle chemistry for the steam-water circuits of fossil-fired and combined-cycle power plants was developed within the IAPWS Power Cycle Chemistry Working Group. This technical guidance document has been authorized by the International Association for the Properties of Water and Steam (IAPWS) at its meeting in Doorwerth, The Netherlands, 6-11 September, 2009, for issue by its Secretariat. The members of the IAPWS are: Britain and Ireland, Canada, the Czech Republic, Denmark, France, Germany, Greece, Japan, Russia, and the United States of America, and the associate members Argentina and Brazil, Italy, and Switzerland. In order to achieve suitable chemical conditions in steam-water circuits it is essential to establish reliable monitoring of key parameters on every plant. This enables the demonstration of ...

2009-10-15

343

Radiological operating experience at FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

The Fast Flux Test Facility has been in operation for approximately five years, including about one thousand days of full power operation of the Fast Test Reactor. During that time the collective dose equivalents received by operating personnel have been about two orders of magnitude lower than those typically received at commercial light water reactors. No major contamination problems have been encountered in operating and maintaining the plant, and release of radioactive gas to the environment has been minimal and well below acceptable limits. All shields have performed satisfactorily. Experience to date indicates an apparent radiological superiority of liquid metal reactor systems over current light water plants.

1987-04-22

344

PSA for CANDU-6 pressurized heavy water reactors: Wolson Units 2,3 and 4 of Korea  

International Nuclear Information System (INIS)

Level 1 and 2 probabilistic safety assessments (PSAs) for both internal and external events are being performed to meet one of the conditions for a construction permit for Wolsong units 2, 3, and 4 in Korea. These units are CANDU-6 Pressurized Heavy Water Reactors (PHWRs), and the study is the first comprehensive level 1 and 2 PSAs for CANDU type plants in the world. The detailed PSA includes and extensive fault tree, event tree analysis, human reliability analysis, and common cause failure analysis. Event trees have been developed for 35 internal initiating event groups. The preliminary results show that the total core damage frequency for Wolsong units 2, 3, and 4 each is similar to that for a typical PWR plant. (author).

1997-06-01

345

Gas turbine tops 40% efficiency; features novel inlet-air cooler  

Energy Technology Data Exchange (ETDEWEB)

This article reports on the world's first gas turbine to top 40% thermal efficiency in simple cycle and is now operating commercially as part of a natural-gas-fired combined-cycle cogeneration (CC) plant serving the Ottawa Health Sciences Center, Ottawa, Ont, Canada. Owned and operated by TransAlta Energy Corp, Calgary, Alta, the CC plant supplies steam and hot and chilled water to the health center and another thermal user while the electricity is sold to Ontario Hydro. Part of the project included the conversion of 15-psig steam-carrying equipment to hot-water service. Commercial success of this installation heralds a new era in the application of efficient gas turbines for power generation.

1993-02-01

346

Extraction of Cs-137 by alcohol-water solvents from plants containing cardiac glycosides  

CERN Document Server

As a result of nuclear power plant accidents, large areas receive radioactive inputs of Cs-137. This cesium accumulates in herbs growing in such territories. The problem is whether the herbs contaminated by radiocesium may be used as a raw material for medicine. The answer depends on the amount of Cs-137 transfered from the contaminated raw material to the medicine. We have presented new results of the transfer of Cs-137 from contaminated Digitalis grandiflora Mill. and Convallaria majalis L. to medicine. We found that the extraction of Cs-137 depends strongly on the hydrophilicity of the solvent. For example 96.5%(vol.) ethyl alcohol extracts less Cs-137 (11.6%) than 40%(vol.) ethyl alcohol or pure water (66.2%). The solubility of the cardiac glycosides is inverse to the solubility of cesium, which may be of use in the technological processes for manufacturing ecologically pure herbal medicine.

2001-01-01

347

Bongs - a new fertilizer plant  

Energy Technology Data Exchange (ETDEWEB)

In an attempt to overcome inadequacies perceived in the approach to providing energy to village communities using the conventional Khadi and Village Industries Commission biogas plant as well as the Janata model, a biogas digester has been developed suitable for a farmer having only one hectare of land. The information on gas yields and other data from a variety of substrates in a laboratory digester are presented. The digester itself consists of a chamber underground into which the influent flows through a channel. Gas is collected in a dome which constitutes the upper part of the digestion chamber and is maintained under pressure by water. The dome can be made of any suitable material such as plastic, ferrocement and brick and mortar. The upper part of the chamber itself is exposed to sun light which enhances microbial growth. Water which surrounds the dome ensures a minimum of temperature variation. 3 references.

1981-01-01

348

Advanced Neutron Source: Plant Design Requirements  

Energy Technology Data Exchange (ETDEWEB)

The Advanced Neutron Source will be a new world-class facility for research using hot, thermal, cold, and ultra-cold neutrons. The heart of the facility will be a 330-MW (fission), heavy-water cooled and heavy-water moderated reactor. The reactor will be housed in a central reactor building, with supporting equipment located in an adjoining reactor support building. An array of cold neutron guides will fan out into a large guide hall, housing about 30 neutron research stations. Appropriate office, laboratory, and shop facilities will be included to provide a complete facility for users. The ANS is scheduled to begin operation at the Oak Ridge National Laboratory early in the next decade. This PDR document defines the plant-level requirements for the design, construction, and operation of ANS. It also defines and provides input to the individual System Design Description (SDD) documents. Together, this PDR document and the ...

1990-07-01

349

Production of cooking briquettes from Maissade (Haiti) lignite. Feasibility study and preliminary plant design  

Energy Technology Data Exchange (ETDEWEB)

A laboratory study was done to establish the technical feasibility of producing domestic cooking briquettes to be marketed in Haiti, from the Maissade lignite reserves of that country, which are high in both ash and sulfur and not yet mined. It was found that acceptable briquettes could be made from Maissade char, pyrolized and compacted with a molasses-lime binder and the addition of bagasse to improve strength and burning rate. Molasses, lime and bagasse are all produced in Haiti. Sodium nitrate was added to enhance ignition, and borax as a wetting and release agent. Standard, ''pillow-shaped'' briquettes were successfully produced on a standard, double roll briquetting machine. The recommended process sequence and equipment selection are virtually identical to that used to produce standard US barbecue briquettes from North Dakota lignite. The heating value of the Maissade briquettes is lower due to their high ash level, which may be acceptable if ...

1986-03-20

350

Insights from Guideline for Performance of Internal Flooding Probabilistic Risk Assessment (IFPRA)  

Energy Technology Data Exchange (ETDEWEB)

An internal flooding (IF) risk assessment refers to the quantitative probabilistic safety assessment (PSA) treatment of flooding as a result of pipe and tank breaks inside the plants, as well as from other recognized flood sources. The industry consensus standard for Internal Events Probabilistic Risk Assessment (ASME-RA-Sb-2005) includes high-level and supporting technical requirements for developing internal flooding probabilistic risk assessment (IFPRA). This industry standard is endorsed in Regulatory Guide 1.200, Revision 1 as an acceptable approach for addressing the risk contribution from IF events for risk informed applications that require U.S. Nuclear Regulatory commission (NRC) approval. In 2006, EPRI published a draft report for IFPRA that addresses the requirements of the ASME PRA consensus standard and have made efforts to refine and update the final EPRI IFPRA guideline. Westinghouse has performed an IFPRA analysis for several nuclear power ...

2009-10-15

351

Vegetation re-establishment on a hardwood forest site denuded by brine  

Energy Technology Data Exchange (ETDEWEB)

Brine from active oil wells seeped through the soil of a forested site in north-western Pennsylvania and killed all vegetation in its path, leaving the affected area unproductive and unsightly. After the brine source was eliminated, herbaceous plants, shrubs and forest tree seedlings became established and developed rapidly. Establishment began in the first year and by Year 4 the site had developed into a healthy young forest. Results show that Allegheny hardwood forest sites damaged by brine water will rapidly revegetate once the brine water discharge is stopped if there is a seed supply and if the area is fenced to exclude deer. 3 figs., 12 refs.

1989-04-01

352

Uptake and translocation of {sup 137}Cs by Houttuynia cordata (in water culture)  

Energy Technology Data Exchange (ETDEWEB)

The water culture experiment of Houttuynia cordata of the medicinal plant was carried out, and basic study on {sup 137}Cs accumulation characteristic and internal circulation in H. cordata in the fruiting stage was investigated since the flowering season. H. cordata accumulated 80% of {sup 137}Cs absorbed unlike K to the root, rhizome, terminal bud of the underground part for the rhizome reproduction. {sup 137}Cs content to the young leaf, spike, involucre increased in the flowering season. Thereafter, {sup 137}Cs was recirculated to the developing organs in second generations such as the rhizome and bud. (author)

2001-08-01

353

Loss of flow accident analysis of a water-cooled fusion reactor  

International Nuclear Information System (INIS)

Within the APROS simulation environment we have built a thermo-hydraulic model of a conceptual fusion power plant which is water cooled and uses lithium-lead for tritium breeding. For the safety assessment of this design we have studied an accident sequence which starts from a loss or coolant flow then leads to first wall breach and pressurisation of the vacuum vessel. Simulations have revealed strong pressure transients which can be alleviated by design changes. One goal is to verify the adequacy of the containment design: it remains intact at least 14 h without any mitigating efforts. Estimates for radioactive releases are obtained. (author)

2003-08-25

354

Hot water from the sun; Increasing awareness of energy saving considerations - thermal solar systems booming. Heisses Wasser von der Sonne; Umweltbewusster Umgang mit Energieressourcen findet immer mehr Anhaenger - Boom fuer thermische Solarsysteme  

Energy Technology Data Exchange (ETDEWEB)

Thermal solar energy plants for water heating have experienced an enormous boom during the last years. Thus, a total of 200000 square metres of collector surface was installed on German rooves in 1991. This was three times as much as in the year before. And this trend of conserving natural resources by using the energy of the sun is still undiminished. (orig.)

1993-11-01

355

Heat rejection system  

Energy Technology Data Exchange (ETDEWEB)

A cooling system for rejecting waste heat consists of a cooling tower incorporating a plurality of coolant tubes provided with cooling fins and each having a plurality of cooling channels therein, means for directing a heat exchange fluid from the power plant through less than the total number of cooling channels to cool the heat exchange fluid under normal ambient temperature conditions, means for directing water through the remaining cooling channels whenever the ambient temperature rises above the temperature at which dry cooling of the heat exchange fluid is sufficient and means for cooling the water. 5 figs.

1980-01-22

356

Effect of secondary circuit materials and water regime on steam generator reliability  

International Nuclear Information System (INIS)

The mechanism of the salt concentration increase in pits and crevices formed in a steam generator due to its imperfect manufacture or to its design features is described. The probability of corrosion can be reduced by choosing a suitable steel and by securing low concentrations of salts (chlorides in particular) and corrosion products in the feedwater. Attention is paid to the distribution of salts in the water-steam circuit and to the conditions of erosion corrosion as the principal source of corrosion products in feedwater. Experience with the suppression of erosion corrosion at nuclear power plants abroad is described. (E.J.).

1989-05-01

357

Daya Bay gets underway  

International Nuclear Information System (INIS)

Unit one of Daya Bay, China's first nuclear power plant was officially opened in February 1994. The nuclear island has been built by Framatome and is an improved version of the Gravelines 5 and 6, 900MWe Pressurized Water Reactors. Extra seismic protection has been included because of greater earthquake risk. The heat exchanger capacity has also been increased as the sea cooling water can be at 30"oC. The technical specifications and details of the fuel loading are given. The technical assistance, management and training of Chinese personnel are discussed. Two further units may be built if Daya Bay 1 is successful. (UK).

358

Causes of denting. Volume 5. Contaminant threshold tests. Final report  

Science.gov (United States)

Steam generators in PWR plants have been subject to denting corrosion as a result of nonprotective magnetite forming on the carbon steel support plate causing the voluminous corrosion product that eventually crimps (dents) the heat transfer tube at the support plate interface. This project was designed to determine the causes of denting and the usefulness of water chemistry changes meant to arrest denting. This volume of the final report describes laboratory research on the correlation of water chemistry, superheat, and oxygen ingress with denting in steam generators.

1983-12-01

359

Water wheeling  

Energy Technology Data Exchange (ETDEWEB)

Two refrains heard in the current retail wheeling debate are that a restructuring of the electric utility industry is inevitable and that its consequences are unpredictable. Notwithstanding the benefits of open competition, there are specific disadvantages of unlimited retail wheeling for some existing independent facilities and especially for hydropower plants. A capital-intensive industry, hydropower is not well-postured to compete effectively in the short-term, against new technologies and fuel sources available in the current marketplace. Hydropower is flat out non-competitive on a price basis with available new capacity. Unless hydro is afforded the same government supports offered to other renewable energy sources, only municipal plants with access to subsidized financing rates and pumped storage plants are going to be built.

1995-03-01

360

Surveillance of terrestrial and aquatic environment of the Chinon nuclear power plant. Year 2002-2003; Surveillance de l'environnement terrestre et aquatique de la centrale de Chinon. Annee 2002-2003  

Energy Technology Data Exchange (ETDEWEB)

We find dosage of gamma emitters radionuclides of samples collected in the environment of the Chinon nuclear power plant for 2002 and 2003, these results are presented in two tables: concentrations in gamma emitter radionuclides of samples collected in the terrestrial environment (soils) and aquatic environment (sediments) of the site of Chinon in june 2002 in the frame of the annual surveillance, the second table concerns the concentrations in gamma emitter radionuclides of samples collected in the terrestrial environment (soils and lichens) of the site of Chinon in may 2003 in the frame of the annual surveillance. We find also the dosage of free tritium in the water of the Loire river for 2002 and 2003, upstream and downstream to the power plant of Chinon. (N.C.)

2003-07-01

361

Integrity of feedwater and main steam piping in KWU light water reactor plants  

Energy Technology Data Exchange (ETDEWEB)

New standard catalogs for piping, supports, and valves have been introduced by Kraftwerk Union (KWU) for the first time in its Convoy series of PWR plants. These catalogs, underlying regulatory codes, and newly developed KWU specifications are described. Feedwater and main steam piping systems within the containment, including pipe supports and valves, are used to demonstrate the high quality level of piping technology achieved in the Federal Republic of Germany. Such quality standards ensure the integrity of single components as well as of the entire system, so that, under certain conditions, pipe whip restraints against postulated breaks have become unnecessary. The quality aspects apply basically for both PWR and BWR plants of KWU.

1986-07-01

362

Fingerprint testing of contaminated ventilation extract filter systems at Sizewell B  

International Nuclear Information System (INIS)

Sizewell B is Nuclear Electric's latest power station, and the Pressurised Water Reactor (PWR) design on which it is based represents a ''first'' for the UK. One of the integral components of the plant is the heating, ventilation and air-conditioning (HVAC) system, which performs a contamination control and gaseous waste management function for the site. During the commissioning of Sizewell B Power Station the extract systems of the HVAC plant underwent a procedure known as ''fingerprinting''. This entailed the characterisation of the facilities provided to test the filtration plant during its lifetime. The assessment of their adequacy was then used to identify necessary modifications and/or to propose the manner in which future in situ performance testing would be carried out. The paper outlines the basic principles and procedure that was used to ''fingerprint'' test systems during the commissioning of ...

363

Environmental impact of a nuclear plant on Mississippi River biota in an ecological recovery zone near Red Wing, Minnesota. Final report  

International Nuclear Information System (INIS)

The biota of the Mississippi River in an ecological recovery zone near Red Wing, MN was studied before and after start-up of a nuclear plant to acquire baseline data and to estimate changes due to thermal addition. Thermal addition produced significant decreases in primary production in a plant region during summer month periods when water temperatures were near 36C. Extensive fisheries studies and sonar tagging/tracking of S. vitreum were performed. Comparison of fisheries results with other riverine, lake, and pond studies indicated a favorable environment for the success of the fish species studied. Qualitative macroinvertebrate surveys were conducted.

364

Ceramic linings beat coal plant's abrasion/corrosion problems  

Energy Technology Data Exchange (ETDEWEB)

A combination of erosion and corrosion at the Victoria Junction coal preparation plant in Sydney, Nova Scotia was causing serious problems. Schedule 80 mild steel pipes were starting to fail as well as some quarter-inch steel plates in the lauders and chutes. Some corrosion tests were carried out and the high chloride level in the process water was felt to be the single most important contribution to the corrosion problem. Cast basalt was selected as a solution to the pipe wear problem. Three different types of abrasion/corrosion-resistant tiling - basalt tiles, kalceram tiles and ceramic tiles were well suited to the chloride conditions at this plant.

1985-07-01

365

Phytoremediation of Ionic and Methyl Mercury P  

Science.gov (United States)

Our long-term goal is to enable highly productive plant species to extract, resist, detoxify, and/or sequester toxic heavy metal pollutants as an environmentally friendly alternative to physical remediation methods. We have focused this phytoremediation research on soil and water-borne ionic and methylmercury. Mercury pollution is a serious world-wide problem affecting the health of human and wild-life populations. Methylmercury, produced by native bacteria at mercury-contaminated wetland sites, is a particularly serious problem due to its extreme toxicity and efficient biomagnification in the food chain. We engineered several plant species (e.g., Arabidopsis, tobacco, canola, yellow poplar, rice) to express the bacterial genes, merB and/or merA, under the control of plant regulatory sequences. These transgenic plants acquired remarkable properties for mercury remediation. (1) ...

1999-06-01

366

FY1998 research report on the basic research on geothermal district heating in Kamchatka, Russia; 1998 nendo Roshia Renpo Kamchatka shu ni okeru chinetsu riyo ni yoru chiiki danbo ni kansuru kiso chosa hokokusho  

Energy Technology Data Exchange (ETDEWEB)

Petropavlovsk-Kamchatky (P-K) city in Kamchatka, Russia is operating hot-water district heating using heavy oil boilers and waste hot water of thermal power plants as heat sources. Feasibility study was made on district heating using natural geothermal hot water and/or geothermal heat pump systems as heat sources of hot water supply for reduction of greenhouse effect gas emission. Among 3 areas including geothermal hot water, use of hot water in K area was impossible because of lower temperature and less spring water. Use of hot water in P and UP areas was impossible as primary hot water because of temperature drop to 64 degrees C during hot water supply toward P-K city. The building heating operation test was carried out using the geothermal heat pump system ...

1999-05-01

367

Korean experience in CANDU-PHWR operation  

Science.gov (United States)

Among KEPCO's 9 nuclear power units, Korea Nuclear Unit No. 3, the Wolsung Nuclear Power Plant is the only CANDU-PHWR Unit, while the rest of 8 others are PWR units. The unit was designed by Atomic Energy of Canada, Ltd. of Canada, who also performed overall project management for the plant construction under the provisions and arrangement of the relevant contracts. The gross electrical output of the plant is 678.7 MWe and thermal output of the reactor is 2061 MWth. While these figures lead to lower plant efficiency than LWR counterparts, unit energy cost for fuel is more favorable than LWRs because natural uranium is utilized for the fuel bundles, some of which are already being fabricated domestically. Annual capacity factors for 1983 and 1984 could have been improved, if two major planned outages for the modification works on steam generator internals and one major forced outage from the ...

1988-01-01

368

Chalon/Saint-Marcel manufacturing plant; L'usine de Chalon/Saint-Marcel  

Energy Technology Data Exchange (ETDEWEB)

AREVA is the world leader in the design and construction of nuclear power plants, the manufacture of heavy components, and the supply of nuclear fuel and nuclear services such as maintenance and inspection. The Equipment Division provides the widest range of nuclear components and equipment, manufactured at its two facilities in Jeumont, northern France, and St. Marcel, in Burgundy. The St. Marcel plant, set on 35 ha (87.5 acres) near Chalon-sur-Saone, was established in 1973 in a region with a long history of specialized metalworking and mechanical activities to meet the demand for non-military nuclear requirements in France. The site offers two advantages: - excellent facilities for loading and transporting heavy components on the Saone river, - it's proximity to other group sites. Since its completion in 1975, the Chalon/St. Marcel facility has manufactured all the heavy components for French pressurized water ...

2008-07-01

369

Suitability of filter ash surfaces as locations for plants  

Energy Technology Data Exchange (ETDEWEB)

The possibility of a positive agricultural use of flue gas filter ash from brown coal power plants is investigated. The suggested measure is mixing ash dump surfaces with extremely acidic spoil bank soils, which balances the high pH value of the alkaline ash and contributes to improved nutrient and soil sorptive conditions. Optimum quantity of spoil bank sands in the mixture with ash is between 10% and 40%. The optimum quantity must be determined for each type of ash considering improvement of soil chemical conditions and water retention capacity. Filter ash properties vary widely; the required amount of spoil bank sand added to investigated ash surfaces near 3 brown coal power plants was between 25% and 30% of the mixture. The same favourable soil and ash mixture can be produced by adding 60% to 75% filter ash to acidic raw spoil bank soil surfaces forming a top soil layer in a thickness of minimum 60 cm. Tests of ...

1980-01-01

370

Probability of failure in BWR reactor coolant piping: Guillotine break indirectly induced by earthquakes  

Energy Technology Data Exchange (ETDEWEB)

The requirements to design nuclear power plants for the effects of an instantaneous double-ended guillotine break (DEGB) of the reactor coolant piping have led to excessive design costs, interference with normal plant operation and maintenance, and unnecessary radiation exposure of plant maintenance personnel. This report describes an aspect of the NRC/Lawrence Livermore National laboratory-sponsored research program aimed at investigating whether the probability of DEGB in Reactor Coolant Loop Piping of nuclear power plants is acceptably small such that the requirements to design for the DEGB effects (e.g., provision of pipe whip restraints) may be removed. This study estimates the probability of indirect DEGB in Reactor Coolant piping as a consequence of seismic-induced structural failures within the containment of the GE supplied boiling water reactor at the Brunswick nuclear ...

1986-12-01

371

Optimal scheduling of power systems with pumped hydropower storage plants adopting nonlinear programming techniques  

Energy Technology Data Exchange (ETDEWEB)

The paper is concerned with the economic operation of power systems comprising pumped storage and thermal plants. In power systems, pumped storage plants may receive the energy required for pumping water either from the system in which they are integrated or from a neighbouring system. Therefore, two mathematical formulations of the problem are presented depending on the source of energy during pumping. In both cases, the problem is reduced to a non linear optimization problem. Two numerical techniques are suggested for the solution of this optimization problem, namely the Lagrangian Multipliers technique and the Rosen Gradient Projection technique. Numerical examples are presented to demonstrate the techniques. Although the Lagrangian Multipliers technique has the advantage of being a well known technique, however, computer wise, the Rosen Gradient Projection technique proves to be more efficient. The results of the ...

1980-12-01

372

Measures for reliability improvement of on-site power plant at steel works  

Energy Technology Data Exchange (ETDEWEB)

This report describes the arrangement and features of the Ogishima thermal power plant facilities, as well as activities being performed there for operation control, regular inspection and improvement in reliability. The power plant uses about 48 percent of the by-product gas as its fuel to supply about 81 percent of the required power. Operation of the No. 1 unit started in 1976. Currently, the plant has three units, each with an output of 125MW. Each unit consists of a natural circulation boiler with a maximum evaporation capacity of 410 ton/hour and a reheat regenerative condensing turbine with a main vapor pressure of 127 kg/cm/sup 2/G. Techniques used for water properties control and combustion control are also described. In the plant, convetional time management integrity techniques are now being replaced by state management integrity techniques that determines the ...

1988-04-15

373

Innovative coke oven gas cleaning system for retrofit applications. Quarterly environmental monitoring report No. 1, January 1, 1991--June 30, 1991  

Energy Technology Data Exchange (ETDEWEB)

The coke plant at the Sparrows Point Plant consist of three coke oven batteries and two coal chemical plants. The by-product coke oven gas (COG) consists primarily of hydrogen, methane, carbon monoxide, nitrogen and contaminants consisting of tars, light oils (benzene, toluene, and xylene) hydrogen sulfide, ammonia, water vapor and other hydrocarbons. This raw coke oven gas needs to be cleaned of most of its contaminants before it can be used as a fuel at other operations at the Sparrows Point Plant. In response to environmental concerns, BSC decided to replace much of the existing coke oven gas treatment facilities in the two coal chemical Plants (A and B) with a group of technologies consisting of: Secondary Cooling of the Coke oven Gas; Hydrogen Sulfide Removal; Ammonia Removal; Deacification of Acid Gases Removed; Ammonia Distillation and Destruction; and, ...

1992-08-24

374

Innovative coke oven gas cleaning system for retrofit applications  

Energy Technology Data Exchange (ETDEWEB)

The coke plant at the Sparrows Point Plant consist of three coke oven batteries and two coal chemical plants. The by-product coke oven gas (COG) consists primarily of hydrogen, methane, carbon monoxide, nitrogen and contaminants consisting of tars, light oils (benzene, toluene, and xylene) hydrogen sulfide, ammonia, water vapor and other hydrocarbons. This raw coke oven gas needs to be cleaned of most of its contaminants before it can be used as a fuel at other operations at the Sparrows Point Plant. In response to environmental concerns, BSC decided to replace much of the existing coke oven gas treatment facilities in the two coal chemical Plants (A and B) with a group of technologies consisting of: Secondary Cooling of the Coke oven Gas; Hydrogen Sulfide Removal; Ammonia Removal; Deacification of Acid Gases Removed; Ammonia Distillation and Destruction; and, ...

1992-08-24

375

Experiences with applications of PSA results for optimization/revision of technical specifications for operation of nuclear power plants  

International Nuclear Information System (INIS)

Over the past few years, NPCIL has performed comprehensive Level-1 Probabilistic Safety Assessment (PSA) for a 220 MWe Pressurised Heavy Water Reactor (PHWR) at Kakrapar Atomic Power Station (KAPS) and for the first 540 MWe PHWR at Tarapur Atomic Power Project (TAPP- 3 and 4). The major objective of these PSAs was to present an integrated picture of the safety of the plant to identify and understand key plant vulnerabilities. As a result of the availability of these PSAs, there is a desire to use them to operate the plants in the most efficient manner practicable. In recent years, the operation of Indian Nuclear Power Plants has been characterized by improved availability/capacity factors and reduced forced outages. Frequency of planned outages is also being reduced. In order to achieve this, the PSAs are now being used as an engineering tool for optimization of Technical ...

2005-12-01

376

Automated method for determining location and magnitude of leaks inside a PWR containment  

Energy Technology Data Exchange (ETDEWEB)

Thermal-hydraulics analysis can be used to determine location and magnitude of leaks inside a pressurized water reactor (PWR) containment, as required by plant technical specifications. The major advantage of this detection method is that it minimizes radiation exposure of maintenance personnel because most of the leak detection process is performed from the control room outside the containment. In addition, such a program allows for the elimination of pipe whip restraints and jet impingement shields, eliminating costs for maintenance of these supports and shields in older plants and lowering construction costs for new plants. Previously, only simple single-node containment models were used for determining leakage magnitude. This paper presents a more sophisticated multinode approach for determining the magnitude and location. The resulting sensitivities to leak can be programmed into the ...

1986-01-01

377

AP1000 plant construction in China: Ansaldo Nucleare contribution  

International Nuclear Information System (INIS)

On 24th of July 2007 Westinghouse Electric Co. signed landmark contracts with China's State Nuclear Power Technology Corporation (SNPTC), to provide four AP1000 nuclear power plants in China. The AP1000 is a two-loop 1117 MWe Pressurized Water Reactor (PWR). It is based on proven technology, but with an emphasis on safety features that rely on natural driving forces, such as pressurized gas, gravity flow, natural circulation flow and convection. Ansaldo Nucleare has provided a significant support to the passive plant technology development and, starting from 2000, is cooperating with Westinghouse to development of the AP1000 Plant. In the frame of the AP1000 Chinese agreement, Ansaldo Nucleare, in Joint Venture with Mangiarotti Nuclear, has signed a contract with Westinghouse for the design and the supply of innovative components to be installed in the first AP1000 unit to be constructed at the Sanmen ...

2009-10-12

378

Influence of feed water distribution pipe replacement on the water chemistry in the steam generator at Loviisa NPP  

International Nuclear Information System (INIS)

Imatran Voima Oy , (IVO) operates two Russian designed nuclear power plants of type VVER440/213. Unit 1 has been operating since 1977 and unit 2 since 1981. First damage of feed water distribution (FWD) pipes was observed in 1989. In closer examinations FWD-pipe T-connection and distribution nozzles suffered from severe erosion corrosion damage. Similar damages have been found also in other VVER-440 type NPPs. In 1994 the first FWD-pipe was replaced by a new design mounted over the tube bundle instead of the old FWD-pipe, which was located inside the tube bundle. The purpose of this paper is to describe the new FWD-pipe and discuss its effects on the steam generator chemistry. (author)

1998-06-01

379

Identification and robust water level control of horizontal steam generators using quantitative feedback theory  

British Library Electronic Table of Contents (United Kingdom)

In this paper, a robust water level control system for the horizontal steam generator (SG) using the quantitative feedback theory (QFT) method is presented. To design a robust QFT controller for the nonlinear uncertain SG, control oriented linear models are identified. Then, the nonlinear system is modeled as an uncertain linear time invariant (LTI) system. The robust designed controller is applied to the nonlinear plant model. This nonlinear model is based on a locally linear neuro-fuzzy (LLNF) model. This model is trained using the locally linear model tree (LOLIMOT) algorithm. Finally, simulation results are employed to show the effectiveness of the designed QFT level controller. It is shown that it will ensure the entire designer's water level closed loop specifications.

2011-01-01

380

Existing systems review of treatment media for the Bear Creek Valley treatability study, Oak Ridge Y-12 Plant, Oak Ridge, Tennessee  

Energy Technology Data Exchange (ETDEWEB)

In situ treatment has been proposed as a remediation alternative for surface water and groundwater contaminated with uranium and nitrate as a result of former waste disposal practices in the S-3 Ponds. Interceptor trenches containing reactive media have been proposed to treat groundwater, and constructed wetlands and/or algal mats are potential alternatives for treating surface water. This report presents the results from testing of ten different reactive media, and combinations of media, that are candidates for use in the proposed interceptor trenches to remove uranium and nitrate from groundwater. It also presents the results of testing and evaluation of algal mats and wetlands for removing uranium and nitrate from surface water.

1998-01-01

381

Economic-impact analysis of effluent limitations and standards for the battery-manufacturing industry  

Energy Technology Data Exchange (ETDEWEB)

The report identifies and analyzes the economic impacts of water pollution control regulations on the battery manufacturing industry. These regulations include effluent limitations and standards based on BPT (best practical control technology currently available), BAT (best available technology economically achievable), PSES (pretreatment standards existing sources), NSPS (new source performance standards), and PSNS (pretreatment standards new sources), that have been promulgated under authority of Sections 301, 304, 306, 307, 308, and 501 of the Federal Water Pollution Control Act, as Amended (the Clean Water Act). The primary economic impact variables of interest include price changes, plant closures, substitution effects, changes in employment, shifts in the balance of foreign trade, changes in industry profitability, structure, and competition, and impacts on small business.

1984-01-01

382

Device for controlling feedwater at low power of nuclear power plants  

International Nuclear Information System (INIS)

Purpose: To provide a feedwater control device capable of minimizing the adverse response of steam drum level at low power. Consitution: In order to perform feedwater control at low power by the substantial control of three factors, that is, main steam flow rate, feedwater flow rate and steam drum level, the main steam flow rate is determined from the reactor output and feedwater rate is determined from the changes in the feedwater temperature due to the mixing of waters in the reactor clean up system and feedwater. If a difference is resulted between these flow rates, a starting feedwater regulator is controlled instantly to eliminate the difference. The water level in the steam drum is used for amending the difference from the final set value of the drum water level, by which the adverse response of the steam drum level can be minimized. (Seki, T.).

383

Behaviour of the steam generators in the Belgian nuclear power plants  

International Nuclear Information System (INIS)

After a brief review of the degradations occurring on tubes of Inconel 600 in steam generators of PWR power stations emphasis is put on the conditioning of the secondary water and more particularly on the condensate treatment in the units of Doel which work on heavily polluted brackish water. The important role of non-destructive testing and eddy-current testing is also pointed out, method developed by Laborelec. The operational experience shows that Belgian stations are nearly not concerned by the degradations mostly found in power stations in other countries which shows the efficiency of the conditioning of the secondary water. On the other hand, other problems have occurred, resulting from: damage caused by foreign objects; fouling of tube before commissioning, cracking of bends and at the limit of the dudgeoning and leaking plugs. (AF).

1986-04-15

384

Acid mine water treatment in wetlands: an overview of an emergent technology  

Energy Technology Data Exchange (ETDEWEB)

Experimental wetlands are being constructed on mined lands in the United States as an inexpensive alternative to conventional acid mine water treatment facilities. The US Bureau of Mines is conducting an inventory of these constructed wetlands as part of a long-term evaluative study. Preliminary results, based on the 20 sites surveyed to date, indicate that the wetlands dominated by emergent species are out-performing the Sphagnum-dominated wetlands, and that much of the water treatment is accomplished by other aspects of the wetland, including bacteria, algae, amendments and other plants. Iron concentrations as high as 85 mg/l are reduced to less than 3 mg/l after flow through the constructed wetlands. Manganese is also removed, though somewhat less efficiently. 12 refs., 1 fig., 1 tab.

1987-12-31

385

Thermal-hydraulic characteristic of the PGV-1000 steam generator  

International Nuclear Information System (INIS)

Horizontal steam generators are typical parts of nuclear power plants with pressure water reactor type VVER. By means of this computer program, a detailed thermal-hydraulic study of the horizontal steam generator PGV-1000 has been carried out and a special attention has been paid to the thermal-hydraulics of the secondary side. A set of important steam generator characteristics has been obtained and analyzed. Some of the interesting results of the analysis are presented in the paper. (author)

1995-09-11

386

The 6th GRS conference  

International Nuclear Information System (INIS)

On the 3. and 4. November 1982 the sixth conference of the Corporation for Reactor Safety (GRS) was held in Cologne's Guerzenich. The theme of this year's meeting was the 'Status of Risk Investigations at Nuclear Power Plants'. A principal topic was a report on findings made by the GRS during the 'Risk Oriented Analysis SNR-300'. The second topic comprised the newest developments within Phase B of the Risk Study of Water Pressure Reactors, the discussion of the dose/effect relationship and considerations on threshold risk values. (orig.).

387

Recent process developments at the SOMAIRE uranium mill  

International Nuclear Information System (INIS)

This paper reviews the mill flowsheet applied at the SOMAIR (Societe des Mines de l'Air) uranium mill in Niger. It focuses on the yellow cake quality improvements achieved by molybdenum and zirconium elimination through double yellow cake precipitation in tanks at first stage and through size/density control in a fluidized bed precipitator at second stage. Water saving aspects in the plant are also presented. (author)

2000-09-09

388

Quantitative Trait Loci for Grain Yield and Adaptation of Durum Wheat (Triticum durum Desf.) Across a Wide Range of Water Availability  

UK PubMed Central (United Kingdom)

Grain yield is a major goal for the improvement of durum wheat, particularly in drought-prone areas. In this study, the genetic basis of grain yield (GY), heading date (HD), and plant height (PH) was...Full Text Available

2008-01-01

389

Phytoremediation of Selenium Contaminated Soil, and Water Produces Biofortified Products and New Agricultural Byproducts  

Science.gov (United States)

Based upon these processes-phytoextraction, phytovolatization and phytostabilization-a plant management remediation strategy for selenium (Se) has been developed for the Westside of Central California. Multi-year field phytoremediation studies were conducted between 2002-2007 on Se-tainted field si...

390

Model tests on a semi-axial pump turbine  

Energy Technology Data Exchange (ETDEWEB)

Due to their good hydraulic characteristic semi-axial pump turbines are used in the medium head range of pumped storage plants. This paper describes model tests performed on a semiaxial pump turbine model and shows the results of these tests. The aim of the model tests was the optimization of the hydraulic water passage, the measurement of the hydraulic characteristics over the whole operating range, the investigation of the cavitation behaviour, the investigation of the hydraulic forces and torques as well as the proof of the values guaranteed to the customer.

1984-03-01

391

Method for the elimination of simple organic compounds by filtration on activated-charcoal particles  

Energy Technology Data Exchange (ETDEWEB)

The use of filters of activated-charcoal particles in drinking-water purification plants assists in the elimination of organic micropollutant substances. The authors report on a study which sought to investigate the mechanism of organic matter; they describe the experimental programme, which used different size ranges of mineral-based activated charcoal, present the experimental findings and discuss the results. 16 references.

1984-12-01

392

Harmful Algae, Nuisance Blooms and Anthropogenic Nutrient Enrichment  

Environmental Research Database

DescriptionPhytoplankton is the collective name given to the microscopic floating plants in seas and lakes. Under certain conditions, the abundance of phytoplankton as a whole or of one or more species in particular, can reach a magnitude at which it is visible through discolouration of the sea. Some of these blooms because of the colour of the water have been called 'Red Tides'. Blooms of some 300 species of the phytoplankton are known as Harmful Algal Bloom (HAB) species in recognition of their poten [continued...

2009-01-31

393

Dual fuel engine solves the solvent problem  

Energy Technology Data Exchange (ETDEWEB)

Some 200 visitors attended the official opening of a new diesel engine driven cogeneration plant in the city of Hamburg at the end of March. The dual fuel engine built by Blohm+Voss will supply 7.7 MW of electricity to the grid and 8.26 MW of thermal power to generate steam and hot water. (author)

1993-05-01

394

Crumbling case for nuclear power  

Energy Technology Data Exchange (ETDEWEB)

In connection with the Public Inquiry into the CEGB proposal to build a pressurised water reactor at Sizewell in Suffolk, the case for nuclear power is examined under the headings: the economics of nuclear power - how they would like them to be; systems analysis - net effective cost; CEGB prejudices the results (comparison with coal-fired plants; forecasting on various assumptions); discounting future costs; back-end costs soar (reprocessing); real reprocessing costs; AGR costs balloon.

1983-01-01

395

Characteristics of U-tube assembly design for CANDU 6 type steam generators  

Energy Technology Data Exchange (ETDEWEB)

Since the first operation of nuclear steam generator early 1960s, its performance requirements have been met but the steam generator problems have been met but the steam generator problems have been major cause of reducing the operational reliability, plant safety and availability. U-tube assembly of steam generator forms the primary system pressure boundary of the plant and have experienced several types of tube degradation problems. Tube failure and leakage resulting from the degradation will cause radioactive contamination of secondary system by the primary coolant, and this may lead to unplanned plant outages and costly repair operations such as tube plugging or steam generator replacement. For the case of steam generators for heavy water reactors, e.g. Wolsong 2, 3, and 4 NPP, a high cost of heavy water will be imposed additionally. During the plant ...

1996-06-01

396

The cascade of reservoirs of the ``Mayak`` Plant: Case history and the first version of a computer simulator  

Energy Technology Data Exchange (ETDEWEB)

The improvement of the ecological conditions at waste storing reservoirs is an important task of the restoration activity at Production Association (PA) ``Mayak`` (South Urals). The radionuclides mostly {sup 90}Sr, {sup 137}Cs, and chemical pollutants deposited in the reservoir water and in the bottom sediment are very dangerous sources for the contamination of Techa River below the reservoirs and the contamination of groundwater in the surrounding formations. The spreading of radioactive contaminants has both hydrogeological and the chemical features. The thermodynamic approach used to account for physical-chemical interactions between water and the bed rocks based on Gibbs free energy minimization of multicomponent system (H-O-Ca-Mg-K-Na-S-Cl-C-Sr) permitted the authors to calculate the corresponding ionic and complex species existing in the solutions, and to characterize the processes of precipitation and dissolution. The model takes into ...

1994-07-01

397

Crud removal performance with ion exchange resins in BWR plants  

Energy Technology Data Exchange (ETDEWEB)

It is needless to say that one of the most important roles of the condensate demineralizer in Japanese boiling water reactors (BWR) is to eliminate such impurities during accidental occurrence of sea water leakage from condensate cooling system. Ion exchange resins packed in condensate demineralizer have also been expected to decrease crud, or corrosion products (CP) in condensate water in order to finally reduce activated corrosion products (ACP) in the reactor coolant loop. It is perceived that crud removal ability of a condensate demineralizer has been improved year by year. And we call this phenomenon as `Aging Effect`. Typical property changes of aged cation exchange resin consisted of an increase of water retention capacity and a change of surface texture. Based on these findings, we formulated a new concept and developed new gel type ion exchange resins for the better crud removal. The results ...

1996-01-01

398

Development of next-generation light water reactor in Japan  

International Nuclear Information System (INIS)

In Japan, the development of next-generation Light Water Reactor has been launched since April 2008. The development program will be completed in 2015. The purpose of development is to cope with the replacement for existing nuclear power plants after 2030 in Japan and the expanding demand for nuclear power in the world; 'Nuclear Renaissance.' The reactor also aims to be global standard at around 2030. The requirements for global standard and domestic users have been investigated through the feasibility study of past 2 years, 2006-2007, and six innovative features or 'Core-Concepts' were established as follows. A) Reactor core system with uranium enrichment above 5% for significant decrease of spent fuel discharge and prominent higher availability B) Long-life materials and innovative water chemistry technologies for 80 years plant lifetime and significant reduction of occupational dose C) Seismic ...

2009-10-27

399

Status of the advanced boiling water reactor and simplified boiling water reactor  

International Nuclear Information System (INIS)

This paper reports that the excess of U.S. electrical generating capacity which has existed for the past 15 years is coming to an end as we enter the 1990s. Environmental and energy security issues associated with fossil fuels are kindling renewed interest in the nuclear option. The importance of these issues are underscored by the National Energy Strategy (NES) which calls for actions which are designed to ensure that the nuclear power option is available to utilities. Utilities, utility associations, and nuclear suppliers, under the leadership of the Nuclear Power Oversight Committee (NPOC), have jointly developed a 14 point strategic plan aimed at establishing a predictable regulatory environment, standardized and pre-licensed Advanced Light Water Reactor (ALWR) nuclear plants, resolving the long-term waste management issue, and other enabling conditions. GE is participating in this national effort and GE's family of advanced nuclear power ...

1992-04-13

400

Carbon Capture and Water Emissions Treatment System (CCWESTRS) at Fossil-Fueled Electric Generating Plants  

Energy Technology Data Exchange (ETDEWEB)

The Tennessee Valley Authority (TVA), the Electric Power Research Institute (EPRI), and the Department of Energy-National Energy Technologies Laboratory (DOE-NETL) are evaluating and demonstrating integration of terrestrial carbon sequestration techniques at a coal-fired electric power plant through the use of Flue Gas Desulfurization (FGD) system gypsum as a soil amendment and mulch, and coal fly ash pond process water for periodic irrigation. From January to March 2002, the Project Team initiated the construction of a 40 ha Carbon Capture and Water Emissions Treatment System (CCWESTRS) near TVA's Paradise Fossil Plant on marginally reclaimed surface coal mine lands in Kentucky. The CCWESTRS is growing commercial grade trees and cover crops and is expected to sequester 1.5-2.0 MT/ha carbon per year over a 20-year period. The concept could be used to meet a portion of the timber ...

2005-08-30

401

The RADionuclide Transport, Removal, and Dose (RADTRAD) code  

Energy Technology Data Exchange (ETDEWEB)

The RADionuclide Transport, Removal, And Dose (RADTRAD) code is designed for US Nuclear Regulatory Commission (USNRC) use to calculate the radiological consequences to the offsite population and to control room operators following a design-basis accident at Light Water Reactor (LWR) power plants. This code utilizes updated reactor accident source terms published in draft NUREG-1465, ``Accident Source Terms for Light-Water Nuclear Power Plants.`` The code will track the transport of radionuclides as they are released from the reactor pressure vessel, travel through the primary containment and other buildings, and are released to the environment. As the radioactive material is transported through the primary containment and other buildings, credit for several removal mechanisms may be taken including sprays, suppression pools, overlying pools, filters, and natural deposition. Simple models are available ...

1993-07-01

402

Fixed time and fixed point observation of environmental radioactivities in Tokyo  

Energy Technology Data Exchange (ETDEWEB)

A measurement of environmental radioactivity in Tokyo was started from 1974. We have been executing fixed time and fixed point observation since 1983 in Tokyo continuously. Measurement item is rain water, airborne dust, activated sludge at sewage treatment plants and external dose rate. Measurement data from 1983 to 1995 is reported in this paper. Moreover, we have been carried out the measurement of radon concentration in air from 1988 to 1991 in different types of residental buildings. The measurement results of rain water, airborne dust, external dose rate were approximately a background level respectively except for the Chernobyl nuclear power plant accident. Radionuclides used as radiopharmaceuticals were detected in the activated sludge at every sewage treatment plant but its concentration was lower than concentration limit in Japan. From a result of radon concentration ...

1997-03-01

403

Biomonitoring for creosote and pentachlorophenol in nearby residents of a wood treatment plant  

Energy Technology Data Exchange (ETDEWEB)

Contaminated wood treatment sites can result in adverse health effects to nearby residents. Environmental exposure can be estimated by measuring concentrations of pollutants in air, water, food, or wipe tests. This environmental exposure value can be used as a surrogate to estimate individual exposure. The objective of this study was to determine whether or not pentachlorophenol (PCP) could be found in potentially exposed residents and if the dioxin levels are consistent with PCP exposure. A further objective of the study was to determine whether or not PAH-DNA adducts could be found in the potentially exposed residents. We present results of biomonitoring studies in residents living near a wood treatment plant that used coal-derived creosote and PCP to process and treat wood for over 100 years. The plant was built in 1904 and used creosote and PCP. Creosote is a complex mixture that contains numerous polycyclic aromatic ...

2004-09-15

404

Assessing the Significance of Above- and Belowground Carbon Allocation of Fast- and Slow-Growing Families of Loblolly Pine - Final Report  

Energy Technology Data Exchange (ETDEWEB)

During this project we experimentally evaluated the below-ground biomass and carbon allocation and partitioning of four different fast- and slow-growing families of loblolly pine located in Scotland County, NC, in an effort to increase the long-term performance of the crop. The trees were subjected to optimal nutrition and control since planting in 1993. Destructive harvests in 1998 and 2000 were used for whole?plant biomass estimates and to identify possible family differences in carbon acquisition (photosynthesis) and water use efficiency. At regular intervals throughout each year we sampled tissues for carbohydrate analyses to assess differences in whole-tree carbon storage. Mini rhizotron observation tubes were installed to monitor root system production and turnover. Stable isotope analysis was used to examine possible functional differences in water and nutrient acquisition of root systems between ...

2001-03-01

405

Soil less culture; I sistemi di coltivazione senza suolo  

Energy Technology Data Exchange (ETDEWEB)

The paper gives a general view of techniques and systems related to soil less culture developed in the last years (on substrate in beg; NFT; Ebb-Flood, aeroponic,..) taking into account their management and problems (water quality, control of plant nutrition and irrigation; substrates; pathological aspects,..). The evolution, now in progress, of soil less culture from open to closed system as a way to realized an environmental friendly growing system, is considered. When plants are grown with open cycle techniques a large amount of waste solution, with an a high content of nutrients, are discharged in soil and water. Furthermore, they need an extra-utilization of water and fertilizers. Another aspect is the utilization of low cost substrates, which can be reused for more than one cultural cycle without negative effects on yield, and also finally discharged without negative effects ...

1996-01-01

406

Safety System Design Concept and Performance Evaluation for a Long Operating Cycle Simplified Boiling Water Reactor  

Science.gov (United States)

The long operating cycle simplified boiling water reactor is a reactor concept that pursues both safety and the economy by employing a natural circulation reactor core without a refueling, a passive decay heat removal, and an integrated building for the reactor and turbine. Throughout the entire spectrum of the design basis accident, the reactor core is kept covered by the passive emergency core cooling system. The decay heat is removed by the conventional active low-pressure residual heat removal system. As for a postulated severe accident, the suppression pool water floods the lower part of the reactor pressure vessel (RPV) in the case when core damage occurs, and the in-vessel retention that keeps the melt inside the RPV is achieved by supplying the coolant. The containment adopts a parallel-double-steel-plate structure similar to a hull structure, which contains coolant between the inner and outer walls to absorb the heat transferred from ...

2003-07-15

407

Nitrogen Requirements and Balance of Protected Cucumber in Coastal Lebanon  

International Nuclear Information System (INIS)

Protected cultures are widespread along the Lebanese narrow coastline, encouraged by mild winter conditions. Although one of the most intensive production systems, water and nutrients managements are mostly empirical, based on the experience of the grower himself or of his workers. So far, water has been available in Lebanon, but it will become scarce within ten years. The conservation of water quality by a rational addition of nutrients is particularly relevant to protected cultures. This is important as greenhouses are developed on imported shallow soils that could be fragile and highly vulnerable to pollution. Sound management includes the amount and the forms of fertilizers as well as the modality of fertigation. An experiment was conducted during two spring seasons in a location along the northern coast in a typical unheated greenhouse. The cucumber response to two frequencies and modalities of fertigation was ...

2003-10-01

408

Material and process improvements in condenser tubing  

Energy Technology Data Exchange (ETDEWEB)

The reliability of the surface condenser is a key factor in plant performance level and maintenance cost optimization. This is especially the case for thermal nuclear plants where condenser raw wa-ter ingress can introduce contamination into the chemically-controlled, steam/water loop potentially causing damage to sensitive equipment. Two important parameters must be taken into account when attempting to optimize the quality and the reliability of condenser tubing. They include selecting the appropriate material according to the cooling water corrosion level present. A second and equally important parameter is the manufac-turing of the tubing product itself. This paper will identify methods to optimize manufacturing processes and improve tubing quality, according to VALTIMET's 30 years of condenser welded tubing production experience. Those methods complete the core ...

2010-07-01

409

Macrofouling control in nuclear power plants  

International Nuclear Information System (INIS)

Macrofouling of cooling-water systems is one of the more significant and costly problems encountered in the nuclear power industry. Both marine and freshwater macroinvertebrates can be responsible for losses in plant availability because of plugged intakes and heat transfer equipment. There is a greater diversity of macrofouling organisms in marine waters than in fresh waters. Marine macrofouling organisms include barnacles, mollusks, bryozoans, and hydroids. Barnacles are crustaceans with feathery appendages, which allow them to attach to a variety of surfaces. They are a major cause of severe macrofouling because they can remain attached even after death. The major freshwater macrofouling organisms include the Asiatic Clam (Corbicula fluminea) and the newest freshwater macrofouler, the Zebra Mussel (Dreissena polymorpha). The introduction of the Zebra Mussel into the Great Lakes has created economic ...

1991-11-10

410

Long-term corrosion study at nuclear power plant Bohunice (Slovakia)  

International Nuclear Information System (INIS)

Steam generators of four VVER-440 units at nuclear power plants V-1 and V-2 in Jaslovske Bohunice (Slovakia) were gradually changed by new original 'Bohunice' design in period 1994-1998. Corrosion processes before and after these design and material changes in Bohunice secondary circuit were studied using Moessbauer spectroscopy during last 25 years. Innovations in the feed water pipeline design as well as material composition improvements were evaluated positively. Moessbauer spectroscopy studies of phase composition of corrosion products were performed on real specimens scrapped from water pipelines or in form of filter deposits. The corrosion of new feed water pipelines system (from austenitic steel) in combination to innovated operation regimes goes dominantly to magnetite. The hematite presence is mostly on the internal surface of steam generator body and its concentration increases towards the top ...

2010-03-01

411

Environmental management plan for the Jhario coalfield - India  

Energy Technology Data Exchange (ETDEWEB)

An Environmental Management Plan (EMP) for the Jharia Coalfield (JCF) was recently completed as part of a World Bank funded project. The JCF, 260 km west of Calcutta, comprises 450 km{sup 2}. Bharat Coking Coal Limited (BCCL) operates an area of 258 km{sup 2}. Coal mining has been conducted for more than 100 years. There are severe constraints to mining due to geology, coal fires and the large population. BCCL counterpart staff participated actively in all aspects of the work. Air and water are heavily polluted, however, mining operations contribute only to a limited extent to the total pollution. Water contamination is generally due to inadequate sewage treatment and discharge from non-mine facilities such as power plants. The large area disturbed by mining to date will increase, as open pit mining operations are expected to expand significantly. Reclamation to date is generally confined to planting of ...

1997-12-31

412

Corrosion failure and its prevention in light water reactor power plants  

Energy Technology Data Exchange (ETDEWEB)

During 17 years since the start of operation of the first commercial LWR in Japan, many LWRs have experienced various corrosion damages, but the causes of them were clarified, and the counter-measures were executed effectively in actual plants, as the results, the cause of corrosion damage decreased remarkably, and now, the high rate of operation has become to be maintained. In this paper, the major cases of corrosion damage experienced in LWRs in Japan and foreign countries, the causes of them and the countermeasures, the problems of hereafter and so on are described. The corrosion damage of metallic materials in the environment of LWRs occurs in the parts in contact with high temperature, high pressure water and steam, such as stainless steel piping in the primary cooling system of BWRs, and nickel alloy heating tubes of steam generators, carbon steel feed water piping and zirconium alloy fuel cladding tubes in PWRs. ...

1988-01-01

413

Corrosion failure and its prevention in light water reactor power plants  

International Nuclear Information System (INIS)

During 17 years since the start of operation of the first commercial LWR in Japan, many LWRs have experienced various corrosion damages, but the causes of them were clarified, and the counter-measures were executed effectively in actual plants, as the results, the cause of corrosion damage decreased remarkably, and now, the high rate of operation has become to be maintained. In this paper, the major cases of corrosion damage experienced in LWRs in Japan and foreign countries, the causes of them and the countermeasures, the problems of hereafter and so on are described. The corrosion damage of metallic materials in the environment of LWRs occurs in the parts in contact with high temperature, high pressure water and steam, such as stainless steel piping in the primary cooling system of BWRs, and nickel alloy heating tubes of steam generators, carbon steel feed water piping and zirconium alloy fuel cladding tubes in PWRs. ...

414

RECOVERY AND SEQUESTRATION OF CO{sub 2} FROM STATIONARY COMBUSTION SYSTEMS BY PHOTOSYNTHESIS OF MICROALGAE  

Energy Technology Data Exchange (ETDEWEB)

Most of the anthropogenic emissions of carbon dioxide result from the combustion of fossil fuels for energy production. Photosynthesis has long been recognized as a means, at least in theory, to sequester anthropogenic carbon dioxide. Aquatic microalgae have been identified as fast growing species whose carbon fixing rates are higher than those of land-based plants by one order of magnitude. Physical Sciences Inc. (PSI), Aquasearch, and the Hawaii Natural Energy Institute at the University of Hawaii are jointly developing technologies for recovery and sequestration of CO{sub 2} from stationary combustion systems by photosynthesis of microalgae. The research is aimed primarily at demonstrating the ability of selected species of microalgae to effectively fix carbon from typical power plant exhaust gases. This report covers the reporting period 1 January to 31 March 2004 in which PSI, Aquasearch and University of Hawaii conducted their tasks. ...

2004-07-01

415

DOE indirect liquefaction program  

Science.gov (United States)

Processes for the hydrogenation of carbon monoxide have had commercial importance since about 1920, when the commercial production of methanol and higher alcohols on oxide catalysts began. Soon thereafter Fischer and Tropsch discovered that liquid hydrocarbons could be synthesized from carbon monoxide and hydrogen over Group VIII metal catalysts. Following extensive catalyst and process development efforts, this technology provided Germany with a source of liquid fuels during World War II. The period following the war saw an acceleration in research and development on the Fischer-Tropsch process, but the only commercial application that was to emerge was the SASOL process in the Union of South Africa. The oil crises of the 1970s have rekindled worldwide interest in indirect liquefaction technologies for the production of clean, high-quality motor fuels from coal. The development of more efficient coal gasification processes and the advent of molecular sieve catalysts that allow ...

1985-01-01

416

Crack growth behaviour of low alloy steels for pressure boundary components under transient light water reactor operating conditions (CASTOC)  

Energy Technology Data Exchange (ETDEWEB)

The CASTOC project addresses environmentally assisted cracking (EAC) phenomena in low alloy steels used for pressure boundary components in both Western type boiling water reactors (BWR) and Russian type pressurised water reactors (VVER). It comprises the four work packages (WP): inter-laboratory comparison test (WP1); EAC behaviour under static load (WP2), EAC behaviour under cyclic load and load transients (WP3); evaluation of the results with regard to their relevance for components in practice (WP4). The use of sophisticated test facilities and measurement techniques for the on-line detection of crack advances have provided a more detailed understanding of the mechanisms of environmentally assisted cracking and provided quantitative data of crack growth rates as a function of loading events and time, respectively. The effect of several major parameters controlling EAC was investigated with particular emphasis on the transferability of the ...

2004-07-01

417

UNSAT-H Version 3.0: Unsaturated Soil Water and Heat Flow Model Theory, User Manual, and Examples  

Energy Technology Data Exchange (ETDEWEB)

The UNSAT-H model was developed at Pacific Northwest National Laboratory (PNNL) to assess the water dynamics of arid sites and, in particular, estimate recharge fluxes for scenarios pertinent to waste disposal facilities. During the last 4 years, the UNSAT-H model received support from the Immobilized Waste Program (IWP) of the Hanford Site's River Protection Project. This program is designing and assessing the performance of on-site disposal facilities to receive radioactive wastes that are currently stored in single- and double-shell tanks at the Hanford Site (LMHC 1999). The IWP is interested in estimates of recharge rates for current conditions and long-term scenarios involving the vadose zone disposal of tank wastes. Simulation modeling with UNSAT-H is one of the methods being used to provide those estimates (e.g., Rockhold et al. 1995; Fayer et al. 1999). To achieve the above goals for assessing water dynamics and estimating ...

2000-06-12

418

The Effect of Static Magnetic Forces on Water Contents and Photosynthetic Pigments in Sweet Basil Ocimum basilicum L. (Lamiaceae)  

International Nuclear Information System (INIS)

Three different magnetic regimes; aerial, surface and buried; each with three different forces, have been used to investigate their effects on the water contents and photosynthetic pigments of sweet basil plants (Ocimum basilicum L.). Two groups of sweet basil seeds, Ocimum basilicum L. have been cultivated, one under normal conditions and the second has been subdivided into three portion (aerial, surface and buried) to examine the effect of different magnetic forces coming from the three directions on the resulted plants. At all directions of magnets, water contents have been significantly affected by the magnetic forces. Chlorophyll A and carotene contents have been affected, as well, according to the three magnetic forces coming from soil surface regime only. Chlorophyll B did not significantly affected by differences magnetic forces in the three regimes, but it is affected by magnetism wherever its ...

419

Suitability of Using Duckweed as Feed and Treated Sewage as Water Source in Tilapia Aquaculture  

International Nuclear Information System (INIS)

Use of treated effluent and duckweed biomass from a pilot-scale UASB-duckweed ponds system treating domestic sewage was evaluated in rearing Nile tilapia (Oreochromis niloticus). Nutritional value of duckweed as sole feed was compared with wheat bran. Two sources of water were used for each feed trial, treated-sewage and freshwater. The experiment was conducted in parallel with a conventional settled sewage-fed fishpond. Results of growth performance demonstrated that, in case of freshwater ponds specific growth rate (SGR) of tilapia fed on fresh duckweed was significantly (p < 0.01) higher than the SGR in wheat bran fed pond. No significant difference (p > 0.05) was observed between the two feeding regimes in treated sewage fed ponds. The SGR of tilapia reared in the treated sewage-wheat bran-fed pond (TWP) was significant higher (p <0.01) than the SGR in the freshwater-wheat bran-fed pond (FWP). On the other hand, due to the early ...

2004-12-27

420

Water-level variations and their effects on tree growth and mortality and on the biogeochemical system at the phytoremediation demonstration site in Fort Worth, Texas, 1996-2003  

Science.gov (United States)

In 1996, a field-scale phytoremediation demonstration project was initiated and managed by the U.S. Air Force at a site in western Fort Worth, Texas, using a plantation of 1-year-old stems harvested from branches of eastern cottonwoods during the dormant season (whips) and a plantation of 1-year-old eastern cottonwood seedlings (calipers). The primary objective of the demonstration project was to determine the effectiveness of eastern cottonwoods at reducing the mass of dissolved trichloroethene transported within an alluvial aquifer. The U.S. Geological Survey conducted a study, in cooperation with the U.S. Air Force, to determine water-level variations and their effects on tree growth and mortality and on the biogeochemical system at the phytoremediation site. As part of the study, water-level and water-quality data were collected throughout the duration of the project. This report presents ...

2004-01-01

421

The Oak Ridge Y-12 Plant biological monitoring and abatement program for East Fork Poplar Creek  

Energy Technology Data Exchange (ETDEWEB)

In May 1985, a National Pollutant Discharge Elimination System permit was issued for the Oak Ridge Y-12 Plant, a nuclear weapons components production facility located in Oak Ridge, Tennessee, and operated by Martin Marietta Energy Systems, Inc., for the US Department of Energy. As a condition of the permit, a Biological Monitoring and Abatement Program (BMAP) was developed to demonstrate that the effluent limitations established for the Oak Ridge Y-12 Plant protect the classified uses of the receiving stream (East Fork Poplar Creek), in particular, the growth and propagation of fish and aquatic life, as designated by the Tennessee Department of Health and Environment. A second purpose for the BMAP is to document the ecological effects resulting from implementation of a water pollution control program that will include construction of nine new wastewater treatment facilities over the next 4 years. Because of the complex ...

1989-10-01

422

Multi-unit Inertial Fusion Energy (IFE) plants producing hydrogen fuel  

International Nuclear Information System (INIS)

A quantitative energy pathway comparison is made between a modern oil refinery and genetic fusion hydrogen plant supporting hybrid-electric cars powered by gasoline and hydrogen-optimized internal combustion engines, respectively, both meeting President Clinton's goal for advanced car goal of 80 mpg gasoline equivalent. The comparison shows that a fusion electric plant producing hydrogen by water electrolysis at 80% efficiency must have an electric capacity of 10 GWe to support as many hydrogen-powered hybrid cars as one modern 200,000 bbl/day-capacity oil refinery could support in gasoline-powered hybrid cars. A 10 GWe fusion electric plant capital cost is limited to 12.5 B$ to produce electricity at 2.3 cents/kWehr, and hydrogen production by electrolysis at 8 $/GJ, for equal consumer fuel cost per passenger mile as in the oil-gasoline-hybrid pathway.

1994-06-20

423

International water power and dam construction handbook  

Energy Technology Data Exchange (ETDEWEB)

The first section of this Handbook describes hydro-electric projects currently under construction or recently commissioned in a number of countries. The major part of the Handbook is devoted to lists of data relating to hydro-electric plants and hydromachinery. These include: data for 1990 submitted by national power authorities on hydro-electric and pumped-storage plants in operation, under construction or planned; more detailed data for pumped-storage plants; country by country data on the dimensions, and reservoir and electrical capacity of major dams and hydro plant; a listing of roller compacted concrete dams; a listing of the world's largest turbines giving data on the largest unit at each scheme in rank order ranging from a unit capacity of 838 MV down to 147 MV; a similar list of the largest hydrogenerators ranging from a unit capacity of 825 MVA down to 150 MVA; details of turbine and ...

1992-01-01

424

Application of a finite element method to leak before break (LBB) of a heat exchanger  

International Nuclear Information System (INIS)

The leak before break (LBB) concept is difficult to apply to a structure with a thin tube that is immersed in a water environment. A heat exchanger in a nuclear power plant is such a structure. The present paper addresses an application of the LBB concept to a heat exchanger in a nuclear power plant. The minimum leaked coolant amount containing the radioactive material which can activate the radiation detector device installed near the heat exchanger is assumed. The postulated initial flaw size that cannot grow to the critical flaw size within the time period to activate the radiation detector is justified. In this case, the radiation detector can activate the warning signal caused by coolant leakage from initially postulated flaws of the heat exchanger. The nuclear plant can safely shutdown when this occurs. Since the postulated initial flaw size can not grow to the critical flaw size, the structural ...

2003-08-17

425

Nuclear desalination for the petrochemical complex of the Natuna project  

International Nuclear Information System (INIS)

On the basis of environmental considerations, a high temperature gas cooled reactor (HTGR) was proposed as the heat source for the Natuna project for CO_2 conversion. To convert CO_2 to useful products, a large amount of high quality water is required for the chemical processes, boilers and other purposes. One LNG production train (maximum of six trains) would produce 0.4 x 10"9 SCF/d of saleable gas and 1.4 x 10"9 SCF/d of CO_2 (in the case of the Exxon process). This CO_2 gas would then be converted to automobile fuel (methane, methanol), which requires a large amount of water. Natural gas from an off- shore gas field is piped to the petrochemical complex on Natuna Island (about 228 km). Natuna is a small island that, apart from sea water, does not have much available water. The desalination process is considered to be the only solution to the water demand problems of the ...

1997-12-01

426

Groundwater management in France: the case of the Seine Basin; La gestion des eaux souterraines en France: exemple du bassin de la Seine  

Energy Technology Data Exchange (ETDEWEB)

In France, groundwater usage represents 40 per cent of volumetric use, outside of thermal power plants. Groundwater represents 60 per cent of domestic and public use, 40 per cent in the industrial sector, and is increasing in the agricultural sector where it accounts for 20 per cent. Groundwater withdrawal in France has slightly increased over the last twenty years and benefited the agricultural sector. Availability throughout the territory, the consistency of resupply and natural quality has rendered groundwater a prevailing source for drinking water. Water protection and management is important and led to the adoption of legislative and regulatory measures. The Mining Code (Code minier) allows for exploitation of underground resources starting at 10 metres. The Rural Code (Code rural) mandates the declaration of public utility for water collection for the public. Protection areas are to be provided ...

2001-07-01

427

The influence of modified water chemistries on metal oxide films, activity build-up and stress corrosion cracking of structural materials in nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

The primary coolant oxidises the surfaces of construction materials in nuclear power plants. The properties of the oxide films influence significantly the extent of incorporation of actuated corrosion products into the primary circuit surfaces, which may cause additional occupational doses for the maintenance personnel. The physical and chemical properties of the oxide films play also an important role in different forms of corrosion observed in power plants. This report gives a short overview of the factors influencing activity build-up and corrosion phenomena in nuclear power plants. Furthermore, the most recent modifications in the water chemistry to decrease these risks are discussed. A special focus is put on zinc water chemistry, and a preliminary discussion on the mechanism via which zinc influences activity build-up is presented. Even though the exact mechanisms by which ...

1999-03-01

428

Operating and commissioning experience with the Dortmund-Derne and Brilon plants; Betriebs- und Inbetriebnahme-Erfahrungen mit den Anlagen Dortmund-Derne und Brilon  

Energy Technology Data Exchange (ETDEWEB)

Initially, the decision of the operator in Dortmund-Derne to select the impact-type separator concept is explained. None of the tenderers for this 52 t/h boiler could supply references for this fluidized bed steam generator concept with staged combustion in a high-expansion fluidized bed. Under the circumstances, the simple configuration of the Steinmueller fluidized bed steam generator, its compact construction, the reduced amount of refractory and the operational behaviour of the boiler resulting therefrom were decisive in the operator`s decision to select this concept. The development schedule shows the individual stages from cold and hot trials in various test rigs and pilot plants to the final design. So far, this fluidized bed steam generator concept has been realized in the plants Derne (52 t/h), commissioned in November 1989, and Brilon (100 t/h), commissioned in November 1990. The discussion on the essential design ...

1992-12-31

429

Large eddy simulation based fire modeling applications for Indian nuclear power plant  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: The Nuclear Power Plants (NPPs) are always designed for the highest level of safety against postulated accidents which may be initiated due to internal or external causes. One of the external/internal causes, which may lead to accident in the reactor and its associated systems, is fire in certain vital areas of the plant. Conventionally, the fire containment approach and/or the fire confinement approach is used in designing the fire protection systems of NPPs. Indian NPPs (PHWRs) follow the combined approach to ensure plant safety and all newly designed plants are required to comply with the provisions of Atomic Energy Regulatory Board (AERB) fire safety Guide. In respect of older plants, the reassessment of adequacy of fire safety provisions in the light of current advances has becomes essential so as to decide upon the steps for retrofitting. ...

2005-07-01

430

GREENHOUSE GAS EMISSIONS CONTROL BY OXYGEN FIRING IN CIRCULATING FLUIDIZED BED BOILERS  

Energy Technology Data Exchange (ETDEWEB)

Given that fossil fuel fired power plants are among the largest and most concentrated producers of CO{sub 2} emissions, recovery and sequestration of CO{sub 2} from the flue gas of such plants has been identified as one of the primary means for reducing anthropogenic CO{sub 2} emissions. In this study, ALSTOM Power Inc. (ALSTOM) has investigated several coal fired power plant configurations designed to capture CO{sub 2} from effluent gas streams for use or sequestration. Burning fossil fuels in mixtures of oxygen and recirculated flue gas (made principally of CO{sub 2}) essentially eliminates the presence of atmospheric nitrogen in the flue gas. The resulting flue gas is comprised primarily of CO{sub 2}. Oxygen firing in utility scale Pulverized Coal (PC) fired boilers has been shown to be a more economical method for CO{sub 2} capture than amine scrubbing (Bozzuto, et al., 2001). Additionally, oxygen firing in Circulating ...

2003-05-15

431

Internal dose from tritium at Wolsung nuclear power plant  

International Nuclear Information System (INIS)

Tritium is produced in large quantities at heavy water nuclear power reactors via the neutron activation reaction "2H(n,#gamma#)"3H. At Wolsung nuclear power plant which has a CANDU reactor, the tritium concentrations in coolant and in moderator systems are 1.5 Ci/Kg-D_2O and 35 Ci/kg-D_2O, respectively, after 12 years of operation. The airborne tritium concentration in main access area is normally less than 5 MPCa except short-term peaks. The average tritium concentrations in main access controlled areas are normally less than 100 MPCa. Tritium is mainly present in the air of workplace of CANDU reactors as a tritiated water vapour. Airborne tritiated water vapour enters the workers body via inhalation and absorption through skin and can result in a significant dose. The occupational doses from tritium at Wolsung NPP have been maintained below 1 man-Sv per year so far. The tritium contribution to the ...

1995-02-01

432

Hydroelectric power stations. Planning, construction and operation; 2. rev. ed.; Wasserkraftanlagen. Planung, Bau und Betrieb  

Energy Technology Data Exchange (ETDEWEB)

Water power plants mean the design, configuration, execution and operation of buildings and of hydraulic and electrical machines. Their many types are due to the stages of development and the technical alternatives of the use of waterpower and the associated energy economy aspects. The main points of this work are the use of water power, different hydro-electric powerstations, water collection, machines and electrotechnical equipment. In the 2nd revised edition parts on electrical engineering, environment, minimum water run-off pumped storage plants, small scole plants, economical aspects and finite elements were broadened. It is a comprehensive textbook and technical book for students of civil engineering and particularly suitable for engineers active in the theory and practice of waterpower construction. (orig./GL) [Deutsch] ...

1998-12-01

433

Hydroelectric power stations. Planning, construction and operation. 4. upd. and enl. ed.; Wasserkraftanlagen. Planung, Bau und Betrieb  

Energy Technology Data Exchange (ETDEWEB)

Water power plants mean the design, configuration, execution and operation of buildings and of hydraulic and electrical machines. Their many types are due to the stages of development and the technical alternatives of the use of waterpower and the associated energy economy aspects. The main points of this work are the use of water power, different hydro-electric powerstations, water collection, machines and electrotechnical equipment. In the 2nd revised edition parts on electrical engineering, environment, minimum water run-off pumped storage plants, small scole plants, economical aspects and finite elements were broadened. It is a comprehensive textbook and technical book for students of civil engineering and particularly suitable for engineers active in the theory and practice of waterpower construction. (orig./GL) [German] Dieses ...

2005-07-01

434

Evaluation of the Validity of Groundwater Samples Obtained Using the Purge Water Management System at SRS  

Energy Technology Data Exchange (ETDEWEB)

As part of the demonstration testing of the Purge Water Management System (PWMS) technology at the Savannah River Site (SRS), four wells were equipped with PWMS units in 1997 and a series of sampling events were conducted at each during 1997-1998. Three of the wells were located in A/M Area while the fourth was located at the Old Radioactive Waste Burial Ground in the General Separations Area.The PWMS is a ''closed-loop'', non-contact, system used to collect and return purge water to the originating aquifer after a sampling event without having significantly altered the water quality. One of the primary concerns as to its applicability at SRS, and elsewhere, is whether the PWMS might resample groundwater that is returned to the aquifer during the previous sampling event. The purpose of the present investigation was to compare groundwater chemical analysis data collected at the four test ...

1999-04-27

435

Removal and recovery system of hexavalent chromium from waste water by tannin gel particles  

Energy Technology Data Exchange (ETDEWEB)

Tannin gel particles that have extremely high adsorption capacity for hexavalent chromium Cr(VI) have been developed by controlling gelation of Mimosa tannin extracted from the bark of plants. The gelation process is composed of two stages; partial gelation of Mimosa tannin by reaction with formaldehyde (cross-linking agent) and granulation by dispersing the partially gelated solution into a liquid mixture of decalin ad a polyether nonionic surfactant with vigorous stirring. The structure of the tannin gel particles is controlled by a combination of operating conditions such as reaction time and temperature at both stages. The water content of the tannin gel particles that reflects their structure can be widely changed from 40 to 79 %(wet basis), even for a constant composition of 23 g Mimosa tannin and 6 ml formaldehyde (37 wt %). It is found that it is very important to increase the water content without losing mechanical ...

2000-10-01

436

Generalized simulation model for reservoir system analysis. Technical paper  

Energy Technology Data Exchange (ETDEWEB)

This paper overviews the general features of computer program 'HEC-5, Simulation of Flood Control and Conservation Systems', with emphasis on the capabilities of the most recent release of HEC-5, Version 7.2, dated March 1991. HEC-5 can simulate the essential features and operation goals and constraints of simple or complex systems with simulation intervals ranging from minutes to one month. Single event flood analysis and period of record conservation analysis may be accomplished with the model. Flood control analysis includes balanced system operation for downstream damage centers with consideration of forecasted local flows and hydrologic routing. In addition, induced surcharge operation based on spillway gate regulation schedules can be simulated. Hydropower analysis may include run-of-river, peaking, and pumped storage plants as well as system power operation. Water supply simulation can include reservoir and downstream ...

1992-03-01

437

Geochemical and petrographic properties of some Spitsbergen coals and dispersed organic matter  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the characteristics of selected parameters of organic matter of the Tertiary coal samples and organic matter of Carboniferous rock samples from the Spitsbergen. The coal samples were taken from Central Coal Basin (the Longyearbyen region) and from the Forlandsundet Basin (Oscar II Land, the Kaffioyra region). Samples of dispersed organic matter were collected from Suffolk Pynten and Sergeijevfjellet area in Sorkapp Land. The optical properties of coal samples are different from properties of dispersed organic matter. Macerals of vitrinite group dominate in all of the samples. The average content of vitrinite group macerals is much lower in dipersed organic matter samples than it is in coals. The average content of liptinite group macerals is a little lower, and inertinite group macerals is much higher. The average content of mineral matter is higher in organic matter samples than in coal samples. The average value of vitrinite reflectance and standard deviation of ...

2004-02-20

438

Development of the hydropower sector in Japan  

Energy Technology Data Exchange (ETDEWEB)

Japan's first water power station to provide public power was the Keage plant (maximum output 160 kW) which began operation in 1891. The installed capacity of pure hydro plants reached 20 481 MW in March 1991; pumped-storage powerplants account for 17 004 MW, making a total of 37 483 MW. Pumped-storage thus represents 45 per cent of total hydro capacity. Pure hydro plants under construction at the end of March 1990 totalled 75, representing 968 MW of capacity. There were also seven pumped-storage plants under construction (each more than 300 MW). The latest survey to establish the hydro potential of Japan indicated the gross theoretical hydro potential to be 717 600 GWh/year and the exploitable potential to be 130 524 GWh/year. Of this exploitable potential, 60 per cent is in operation and 3 per cent is under construction. The exploitable potential represents 4551 pure ...

1991-11-01

439

Coal gasification via the Lurgi process: Topical report: Volume 1, Production of SNG (substitute material gas)  

Energy Technology Data Exchange (ETDEWEB)

A Lurgi baseline study was requested by the DOE/GRI Operating Committee of the Joint Coal Gasification Program for the purpose of updating the economics of earlier Lurgi coal gasification plant studies for the production of substitute natural gas (SNG) based on commercially advanced technologies. The current study incorporates the recent experience with large size Lurgi plants in an effort to improve capital and operating costs of earlier plant designs. The present coal gasification study is based on a mine mouth plant producing 250 billion Btu (HHV) per day of SNG using the Lurgi dry bottom coal gasification technology. A Western subbituminous coal was designated as the plant food, obtained from the Rosebud seam at Colstrip, Montana. This study presents the detailed description of an integrated facility which utilizes coal, air, and water to produce 250 billion ...

1984-09-01

440

PROBABILISTIC SAFETY ASSESSMENT OF OPERATIONAL ACCIDENTS AT THE WASTE ISOLATION PILOT PLANT  

Energy Technology Data Exchange (ETDEWEB)

This report presents a probabilistic safety assessment of radioactive doses as consequences from accident scenarios to complement the deterministic assessment presented in the Waste Isolation Pilot Plant (WIPP) Safety Analysis Report (SAR). The International Council of Radiation Protection (ICRP) recommends both assessments be conducted to ensure that ''an adequate level of safety has been achieved and that no major contributors to risk are overlooked'' (ICRP 1993). To that end, the probabilistic assessment for the WIPP accident scenarios addresses the wide range of assumptions, e.g. the range of values representing the radioactive source of an accident, that could possibly have been overlooked by the SAR. Routine releases of radionuclides from the WIPP repository to the environment during the waste emplacement operations are expected to be essentially zero. In contrast, potential accidental releases from ...

2000-09-01

441

WCOORDINAMTE SCIENCE ABOA TOVRY - NASA Technical Reports Server  

Science.gov (United States)

2.1.1 Stochastic decision and control approaches .... 14. 2.1.2 Queueing theory ...... Infoton Vistar/2 terminal keyboard) is used by the pilot for ...

442

South Downs Lifescapes Joint Data Management  

Environmental Research Database

ObjectivesTo determine what biodiversity data is held by record centres for the South Downs Lifescapes pilot area and the format in which it is stored.

2004-01-31

443

Reformulation of Consumer Health Queries with Professional Terminology: A Pilot Study  

UK PubMed Central (United Kingdom)

Background The Internet is becoming an increasingly important resource for health-information seekers. However, consumers often do not use effective search...Full Text Available

444

NASAPerformance Report - NASA Technical Reports Server  

Science.gov (United States)

test bed (ADTT) tools technology. Glenn. Research. Center: Aircraft icing training video for regional and cor- porate pilots. Numerical propulsion ...

445

Mq M6B - NASA Technical Report Server (NTRS)  

Science.gov (United States)

controlled by pedel inputs. Forward flight cherecteristics of a helicopter tend to resemble those of an airplene, thus the pilot ...

446

Gallium Arsenide Pilot Line for High Performance ...  

Science.gov (United States)

... used in our aluminum process include a barrier to isolate aluminum from the gold-based ohmic contacts, thereby preventing "purple plague," and a ...

1991-08-08

447

Flue gas desulfurization pilot study: summary of phase I and phase II reports  

Science.gov (United States)

The initial phase of this study consisted of a survey of existing FGD systems used on larger combustion processes in the NATO countries and Japan.

1980-04-01

448

CIVIL USES OF REMOTELY PILOTED AIRCRAFT' - NASA Technical Report ...  

Science.gov (United States)

to, an altitude of 5000 ft (1500 m) AGL and f4.ies tight circles. If link has ...... The learning-curve effect reflects the observable ...

449

AIR ... - Human Factors Research and Technology Division - NASA  

Science.gov (United States)

TRACON controller, traffic flow manager, or pilot. .... separation violations to individual controller and ..... System, AGARD Meeting on Machine Intelligence ...

450

Using of Itaipu hydroelectric power plant-Brazil-electric power surplus for ammonia synthesis in nitrogen fertilizers production; Utilizacao da energia junto a Usina Hidreletrica de Itaipu para a sintese de amonia para fertilizantes nitrogenados  

Energy Technology Data Exchange (ETDEWEB)

Secondary energy can be described as a surplus of electrical energy in a hydropower because the lower demand of energy in some period of the day and the excess of water in the reservoir during the rainy periods. This study proposes the using of the excess of energy at Itaipu Bi nacional for electrolytically hydrogen production and ammonia for nitrogenous fertilizers. Ammonia is a raw material for nitrogenous fertilizers synthesis and produced using hydrogen and nitrogen from the atmosphere. This paper determines the minimal cost of hydrogen production and the capacity of hydrogen production, with this data and according the ammonia market for nitrogenous fertilizers in the Centre/South region was estimated the better capacity of ammonia production for one plant near Itaipu. The process of ammonia production using energy excess is the most environmental acceptable. (author)

2000-07-01

451

Structure and antimicrobial activity relationship of quaternary N-alkyl chitosan derivatives against some plant pathogens  

British Library Electronic Table of Contents (United Kingdom)

In the present work, quaternary chitosans as water-soluble compounds were prepared based on three-step process. Schiff bases were firstly synthesized by the reaction between the amino groups of chitosan with aliphatic aldehydes followed by a reduction with sodium borohydride (NaBH4) to form N-(alkyl) chitosans. N,N,N-(dimethyl alkyl) chitosans were then obtained by a reaction of chitosan containing N-butyl, N-pentyl, N-hexyl, N-heptyl, and N-octyl substituents with methyl iodide. The compounds were characterized using IR and NMR spectroscopy. Subsequent experiments were conducted to test their antimicrobial activities against the most economic plant pathogenic bacteria of crown gall disease Agrobacterium tumefaciens, soft mold disease Erwinia carotovora, fungi of grey mold Botrytis cinerea...

2010-01-01

452

Simultaneous ozonation kinetics of phenolic acids present in wastewaters  

Energy Technology Data Exchange (ETDEWEB)

Among the several chemical processes conducted for the removal of organic matter present in wastewaters coming from some agro-industrial plants (wine distilleries, olive oil mills, etc), the oxidation by ozone has shown a great effectiveness in the destruction of specially refractory pollutants: it is demonstrated that the biodegradability of those wastewaters increases aflcer an ozonation pretreatment. Their great pollutant character is imputed to the presence of some organic compounds, like phenols and polyphenols, which are toxic and inhibit the latter biological treatments. In this research, a competitive kinetic procedure reported by Clurol and Nekouinaini is applied to determine the degradation rate constants by ozone of several phenolic acids which are present in the wastewaters from the olive oil obtaining process. The resulting kinetic expressions for the ozonation reactions are useful for the successful design and operation of ozone reactors in ...

1996-12-31

453

Retinue of the beans roots growth by using neutron radiography technique  

International Nuclear Information System (INIS)

Agricultural practices frequently cause the development of a soil compacted layer below the surface. These compacted layers restrict the root penetration into deeper layers of soil, in search for water. It is proposed to monitor, using Non Destructive Test, the roots growth due to the planting of standard seeds in different agricultural soils, in function of their compactness and humidity. It will be used the neutrons beams derived from an irradiation channel called J-9 of the Reactor Argonauta (IEN/CNEN), so that the neutron radiographic images of the soil-plant system can be obtained. Each root can be evaluated for its ability to penetrate into compacted soil layers; this fact would mean an optimization of agricultural harvests. (author)

2002-08-11

454

Process to remove the residue of the waste gas scrubbing from firings, particularly bituminous coal power plants. Verfahren zur Beseitigung des Rueckstandes der Abgaswaesche von Feuerungen, insbesondere von Steinkohlenkraftwerken  

Energy Technology Data Exchange (ETDEWEB)

Calcium sulfate dihydrate which is co-produced in the scrubbing of waste gases from bituminous coal power plants is employed in the underground road securing after recrystallization. Beta-sulfate semi hydrate is obtained from the dihydrate by recrystallisation and it is used as such or as a stiff mixture with additives as a stowing material. Particularly fly ash from coal combustion units, washery refuses and development rocks from coal mining or slags from the metallurgical industry can be used as additives. The compressive and the bending tensile strength of the stowing material can be adjusted by the water content in case beta sulfate semihydrate is used as such.

1980-08-28

455

Natural gas usage as a heat source for integrated SMR and thermochemical hydrogen production technologies  

British Library Electronic Table of Contents (United Kingdom)

This paper investigates various usages of natural gas (NG) as an energy source for different hydrogen production technologies. A comparison is made between the different methods of hydrogen production, based on the total amount of natural gas needed to produce a specific quantity of hydrogen, carbon dioxide emissions per mole of hydrogen produced, water requirements per mole of hydrogen produced, and a cost sensitivity analysis that takes into account the fuel cost, carbon dioxide capture cost and a carbon tax. The methods examined are the copper-chlorine (Cu-Cl) thermochemical cycle, steam methane reforming (SMR) and a modified sulfur-iodine (S-I) thermochemical cycle. Also, an integrated Cu-Cl/SMR plant is examined to show the unique advantages of modifying existing SMR plants with new h...

2010-01-01

456

Mechanism of nanocapsules of Matricaria recutita L. extract formation by the emulsion-diffusion process  

British Library Electronic Table of Contents (United Kingdom)

Nanocapsules coated by medicinal plants have many applications in drug manufacturing. Medicinal plants can be loaded on nanocapsules with polyesteric triblock copolymer poly ethylene glycol-poly butylene adipate-poly ethylene glycol (PEG-PBA-PEG) as shell and olive oil can be introduced as a core of nanocapsules by a method known as polymer deposition solvent evaporation method. In this research, first, certain amount of polymer, Matricaria recutita extract and olive oil were mixed with acetone and then, water was added to the solution using magnetic stirrer. After which the acetone was removed by vacuuming and finally nanocapsules were found by freezing-drier. The study showed the size of nanocapsules depends on variety of factors such as the ratio of polymer to oil and concentration of p...

2011-01-01

457

Integrated method of RS and GPR for monitoring the changes in the soil moisture and groundwater environment due to underground coal mining  

British Library Electronic Table of Contents (United Kingdom)

Mining affects the environment in different ways depending on the physical context in which the mining occurs. In mining areas with an arid environment, mining affects plants? growth by changing the amount of available water. This paper discusses the effects of mining on two important determinants of plant growth?soil moisture and groundwater table (GWT)?which were investigated using an integrated approach involving a field sampling investigation with remote sensing (RS) and ground-penetrating radar (GPR). To calculate and map the distribution of soil moisture for a target area, we initially analyzed four models for regression analysis between soil moisture and apparent thermal inertia and finally selected a linear model for modeling the soil moisture at a depth 10?cm; the relative error o...

2009-01-01

458

Hydrodynamics induced vibration to trash-racks  

International Nuclear Information System (INIS)

In conventional power plants trash-racks are provided at the intakes to protect the turbines. In pumped storage plants, the draft tube or tailrace must also have trash-racks to protect the units while pumping. Because the loads believed to cause many failures of trash-racks are dynamic in nature, it is important to understand the dynamic characteristics of trash-racks structures in general and a single rack in particular. The classical added-mass solution structure-fluid dynamic interaction is known as an approximate solution procedure. An accurate added-mass approach mixed with implementation in finite element framework is proposed. In this proposal, experimental conclusions, supported by theory, led to presentation of more accurate results in vibration of trash-racks. This numerical solution as a powerful method to solve such a complex problem can be employed to carry out dynamic characteristics of these structures while vibrating in ...

2002-12-01

459

Estimating pressurized water reactor decommissioning costs: A user`s manual for the PWR Cost Estimating Computer Program (CECP) software. Draft report for comment  

Energy Technology Data Exchange (ETDEWEB)

With the issuance of the Decommissioning Rule (July 27, 1988), nuclear power plant licensees are required to submit to the US Regulatory Commission (NRC) for review, decommissioning plans and cost estimates. This user`s manual and the accompanying Cost Estimating Computer Program (CECP) software provide a cost-calculating methodology to the NRC staff that will assist them in assessing the adequacy of the licensee submittals. The CECP, designed to be used on a personnel computer, provides estimates for the cost of decommissioning PWR plant stations to the point of license termination. Such cost estimates include component, piping, and equipment removal costs; packaging costs; decontamination costs; transportation costs; burial costs; and manpower costs. In addition to costs, the CECP also calculates burial volumes, person-hours, crew-hours, and exposure person-hours associated with decommissioning.

1993-10-01

460

DOE Plutonium Disposition Study: Pu consumption in ALWRs. Volume 1, Final report  

Energy Technology Data Exchange (ETDEWEB)

The Department of Energy (DOE) has contracted with Asea Brown Boveri-Combustion Engineering (ABB-CE) to provide information on the capability of ABB-CE`s System 80 + Advanced Light Water Reactor (ALWR) to transform, through reactor burnup, 100 metric tonnes (MT) of weapons grade plutonium (Pu) into a form which is not readily useable in weapons. This information is being developed as part of DOE`s Plutonium Disposition Study, initiated by DOE in response to Congressional action. This document, Volume 1, presents a technical description of the various elements of the System 80 + Standard Plant Design upon which the Plutonium Disposition Study was based. The System 80 + Standard Design is fully developed and directly suited to meeting the mission objectives for plutonium disposal. The bass U0{sub 2} plant design is discussed here.

1993-05-15

461

Containment integrated leakage rate test (ILRT) of Indian PHWR  

International Nuclear Information System (INIS)

Integrated Leakage Rate Test (ILRT) of containment system plays a very important role in safety of a Nuclear Power Plant. Containment system constitutes the last physical barrier to release of radioactivity from the core and is called upon to mitigate the consequences of not only accidents within the design basis, but also some of the highly unlikely severe accidents. Hence, leak tightness of containment becomes uttermost priority for the safety of plant personnel and public. The containment and associated ESFs are tested before the first criticality and there after periodically during service. The pre-operational integrated leakage rate is carried out at LOCA based design pressure, at periodic test pressure and at some intermediate pressure points to assess the leakage characteristics. This paper summarizes the various requirements and activities relevant to the ILRT of the Indian Pressurized Heavy Water Reactor (PHWR) ...

2005-12-01

462

Characterization and uncertainty analysis of VOCs emissions from industrial wastewater treatment plants  

British Library Electronic Table of Contents (United Kingdom)

Air toxics from the industrial wastewater treatment plants (IWTPs) impose serious health concerns on its surrounding residential neighborhoods. To address such health concerns, one of the key challenges is to quantify the air emissions from the IWTPs. The objective here is to characterize the air emissions from the IWTPs and quantify its associated uncertainty. An IWTP receiving the wastewaters from an airplane maintenance facility is used for illustration with focus on the quantification of air emissions for benzyl alcohol, phenol, methylene chloride, 2-butanone, and acetone. Two general fate models, i.e., WATER9 and TOXCHEM+V3.0 were used to model the IWTP and quantify the air emissions. Monte Carlo and Bootstrap simulation were used for uncertainty analysis. On average, air emissions fr...

2010-01-01

463

Causes of denting. Volume 1. Summary report. Final report  

Science.gov (United States)

This summary report outlines the work that was performed to gain a more complete understanding of denting corrosion of steam generators in PWRs. Background laboratory and plant data on denting were compiled, reviewed and correlated to determine how various exposure conditions affect denting. Two high-temperature chemistry analytical models were reviewed and evaluated by experimental simulation of impurity concentration in the heat transfer and isothermal capsule tests. Simulation of impurity concentration for three cooling waters (lake, river, and cooling tower) was evaluated. The effects of species concentration (Cu/sup + +/, Cl/sup -/, O/sub 2/, and H/sup +/), contaminant thresholds (established by isothermal and heat transfer tests), and heat flux as indicated by superheat on denting were examined. A discussion of several pertinent observations and conclusions drawn from these tasks (as they pertain to plant operation) ...

1984-05-01

464

Application of leak-before-break approach to PWR piping designed by Babcock and Wilcox: Final report  

Energy Technology Data Exchange (ETDEWEB)

Recently, the leak-before-break (LBB) concept has been used successfully to eliminate some pipe whip restraints, snubbers and jet impingement shields from the primary reactor cooling system piping of pressurized water reactors. This has resulted in substantial savings in maintenance costs, reductions in radiation exposure of plant service personnel, and has enhanced the overall safety of nuclear power plants. This study provides guidelines to utilities in expanding the application of the LBB concept to additional pipe systems and it couples the concept with hardware optimization. Seven high energy piping systems were investigated for technical feasibility in using the LBB concept. The results indicate that some of these seven lines are good candidates for the leak-before-break application.

1987-01-01

465

Shooting from the HIP: Hyperion's efforts to clean Santa Monica Bay. [Hyperion Improvement Program (HIP)  

Energy Technology Data Exchange (ETDEWEB)

The Outstanding Achievement Award in Water Pollution Control' is intended to recognize the water pollution control program that best demonstrates achieving significant, lasting, and measurable excellence in water-quality improvement in preventing water-quality degradation in a region, basin, or water body. This article is about the 1991 Award. This year, WPCF honored Los Angeles Hyperion Treatment Plant with a citation of outstanding achievement. To qualify for this honor, Hyperion has remarkably improved the quality of wastewater discharged to Santa Monica Bay since 1985. Capital programs developed by Los Angeles to achieve this rapid improvement, coined the Hyperion Improvement Program (HIP), reflect the city's commitment to protect the valuable resource of Santa Monica Bay. The HIP was conceived in 1986 to cease sludge ocean disposal by the ...

1991-11-01

466

Regulation of sucrose synthesis in water stressed leaves  

Energy Technology Data Exchange (ETDEWEB)

Alteration in carbon metabolism and carbohydrate partitioning occur in drought stressed plants. Some species accumulate large quantities of starch in the chloroplast, which may be used to support sucrose synthesis under conditions of limited carbon supply. The authors monitored chemical partitioning of carbon between sugars and starch and the activity of sucrose phosphate synthase (SPS) and fructose 1,6 bisphosphatase (FBPase) in the source leaves of water stressed tomatoes. Plants were stressed by withdrawing water for 10 days and rewatered for recovery. Water potential dropped from {minus}0.8 to {minus}2.2MPA in 10 days, but recovered to control level 2 days after rewatering. Photosynthetic rates as measured by the activity of Rubisco followed similar patterns to those of water potential. After 10 days, leaf starch levels decreased to less than 50% of control. ...

1991-05-01

467

From tankers to tissues : tracking the degradation and fate of oil discharges in Port Valdez, Alaska  

Energy Technology Data Exchange (ETDEWEB)

An average of 9 million gallons per day of oil-contaminated ballast water off loaded from tankers are treated at the Alyeska Pipeline Service Company Ballast Water Treatment Facility at the terminus of the Trans-Alaska Pipeline in Port Valdez, Alaska. This paper focuses on the results of 2 Prince William Sound Regional Citizens' Advisory Council monitoring programs which detail changes in the chemical composition of treated ballast water as it moves from tankers through the facility and subsequently traces the effluent hydrocarbons into the receiving environment of Port Valdez. The treatment facility involves gravity separation tanks, dissolved air flotation cells and biological treatment tanks. Effluent containing traces of volatile aromatics, including benzene, toluene, ethylbenzene and xylenes, low levels of oil, saturated hydrocarbons and polycyclic aromatic hydrocarbons is being continuously discharged to Port ...

2005-07-01

468

Trichoderma-fortified compost extracts for the control of choanephora wet rot in okra production  

British Library Electronic Table of Contents (United Kingdom)

The potential of water extracts produced from rice straw (RST) and empty fruit bunch of oil palm (EFB) composts fortified with Trichoderma harzianum for the control of Choanephora wet rot of okra caused by Choanephora cucurbitarum was studied under field conditions. Disease severity was lowest in plants treated with Trichoderma-fortified RST extracts (9.56%) with a disease index of 1, mancozeb (Dithane M-45 (2gl-1 of water), Trichoderma-fortified EFB compost extracts, extracts of RST and EFB, and an aqueous suspension of T. harzianum recorded disease severity values of 10.25%, 19.38%, 37.56%, 53.71% and 56.36%, with a disease index of 1, 1, 2, 3 and 3, respectively. There was a reduction of 85.04% in Choanephora wet rot severity on okra treated with Trichoderma-fortified RST extracts durin...

2008-01-01

469

Technical-economic aspects of the utilization of geothermal waters  

International Nuclear Information System (INIS)

A brief description is given of the physico-chemical parameters characterized a hot water geothermal reservoir and of its exploitation by means of single or coupled (doublet) wells. The technical aspects of geothermal heat to the users is then discussed, beginning with corrosion of materials caused by seven main agents: oxygen, hydrogen sulphide, carbon dioxide, ammonia, hydrogen, sulphates and chlorides. A brief mention is made of scaling due to calcium carbonate, silica and calcium sulphates. The basic components of a geothermal plant for non-electric uses are then discussed: production pumps, surface pipelines, heat exchangers, heat pumps and reinjection pumps. The advantages and disadvantages of the different equipment and materials used in the geothermal sector are also presented. A list is also given of the criteria used in the energy and economic balance of a geothermal operation. (author). 24 refs, 13 figs, 2 tabs.

470

Steam generator tube performance: experience with water-cooled nuclear power reactors during 1979  

International Nuclear Information System (INIS)

The performance of steam generator tubes in water-cooled nuclear power reactors has been reviewed for 1979. Tube failures occurred at 38 of the 93 reactors surveyed. Causes of these failures and procedures designed to deal with them are described. The defect rate was twice that in 1978 but still lower than the two previous years. Methods being employed to detect defects include increasing use of multifrequency eddy-current testing and a trend to full-length inspection of all tubes. To reduce the incidence of tube failures by corrosion, plant operators are turning to full-flow condensate demineralization and more leak-resistant condenser tubes. (author).

1994-10-18

471

Special features of control and protection for large saturated steam turbines  

International Nuclear Information System (INIS)

For shut-down safety of the turbine generator (securing of auxiliary power operation after load shut-down and preventing the reaching of overspeed after load shut-down with disturbed turbine governing system) additional measures compared to those for superheated steam turbines are required for turbine generators in plants with pressurized water reactor (PWR) as well as those with boiling water reactor (BWR) . Equipment is described (e.g. overspeed govern or selecting connection, vacuum breaker, bypass valves, intercepting valves) which, depending on the own conditions of the individual turbine generator (e.g. run-up time, vacuum, enclosed energy), may be applied alone or in jointly. (orig.).

472

Series of surveys for enteric viruses and indicator organisms in Tokyo Bay after an event of combined sewer overflow.  

Science.gov (United States)

Combined sewer overflows (CSOs) have been recognised as one of the serious sources of pollution to the water environment during rain events, although field surveys to investigate the effect of their magnitude and duration on receiving waters have been very limited. The fates of enteric viruses (norovirus G1, G2, enteroviruses) and coliforms were determined in the wastewater treatment plant on a fine day and on a rainy day. Not all microorganisms were reduced in the primary treatment, but were reduced in the secondary treatment. Occurrences of enteric viruses and levels of coliforms were surveyed in the receiving coastal area after a CSO event, with the profiles of the enteric viruses in the coastal seawater being almost at the same positive ratio for 4 d after the CSO event. PMID:15318519

2004-01-01

473

PSPs at Bhira and Bhivpuri  

International Nuclear Information System (INIS)

Tata Electric Companies (TEC) are engaged in the generation of hydro and thermal energy. TEC, to minimise backing down of its thermal units in off peak hours and also to at least partially meet the growing deficit in the supply during peak hours is moving to install pumped storage plants (PSPs) utilising off-peak surplus energy for pumping the water from lower pond to the upper pond for subsequent utilisation for power generation during peak hours. In view of some of the infra structural facilities such as storage ponds, water conductor system, transmission lines, etc. being already available, at the existing hydro power stations owned by TEC, the pumped storage units are being proposed within the environs of existing hydro stations, i.e. a 150 MW pumped storage unit at Bhira and a 90 MW pumped storage unit at Bhivpuri. The projects are described and cost estimates is given. (author). 2 figs.

1992-01-01

474

New technology for purging the steam generators of nuclear power plants  

British Library Electronic Table of Contents (United Kingdom)

A technology for removal of undissolved impurities from a horizontal steam generator using purge water is developed on the basis of a theoretical analysis. A purge with a maximal flow rate is drawn off from the zone with the highest accumulation of sludge in the lower part of the steam generator after the main circulation pump of the corresponding loop is shut off and the temperatures of the heat transfer medium at the inlet and outlet of the steam generator have equilibrated. An improved purge configuration is used for this technology; it employs shutoff and regulator valves, periodic purge lines separated by a cutoff fixture, and a D y 100 drain union as a connector for the periodic purge. Field tests show that the efficiency of this technology for sludge removal by purge water is severa...

2011-01-01

475

Flue gas desulfurization process, study. phase I. Survey of major installations. Appendix 95-d, Sea water scrubbing flue gas desulfurization process  

Science.gov (United States)

An assessment study of the sea water scrubbing process for flue gas desulfurization has been made by SINTEF. This project has been financially supported by the Royal Ministry of Environment of Norway. The study is based on three FGD-units which are installed at three oil-fired, industrial boilers respectively with a maximum continuous heat input of 130 MW (27 MW + 2x51.5 MW) corresponding to approximately 50 MWE (10 MWE + 2x20 MWE) generating capacity for a power plant having a net efficiency of 38%.

1979-01-01

476

Effects of boron pollution in the lower buyuk menderes basin (Turkey) on agricultural areas and crops  

British Library Electronic Table of Contents (United Kingdom)

Abstract The aim of this study is to study the effects of Boron (B) pollution in Buyuk Menderes river on planted crops and agricultural areas constructed in the irrigation schemes by the State Hydraulic Works (DSI) of the Lower Buyuk Menderes basin, Turkey. The studied irrigation schemes in the basin are Saraykoy, Pamukkale, Nazilli, Aydin, Sultanhisar, Koarli, and Soke. Mean B concentrations of river water used in the irrigation schemes ranged from 0.10 to 0.43 mgB L-1 for the period of 2008 to 2009. A total of 100,556 ha of the agricultural area and the basin groundwater resources are under the influence of B pollution from the Buyuk Menderes river. The amount of B accumulating in soils and seepage in the groundwater due to the used irrigation water was 18,495,350 and 9153 kgB yr-1, resp...

2011-01-01

477

Construction progress of the cooling & ventilation in the LHC project  

CERN Document Server

After the LEP dismantling Phase the Cooling and Ventilation Group has started the LHC construction work. Year 2001 through to 2004 will certainly be the most important period of activity for the CV group in the erection phase The author will report on the current works that are in progress on the different LHC Points distinguishing between the Ventilation and the Water Cooling installations. The Ventilation work completed in the new surface buildings in Points 1, 4,5,6 and 8. The work for the Cooling plants comprehend to the pumping stations, the cooling towers and the chilled water production stations in Points 1 and 5, For all of these activities, an updated report of the progress the work, the planning and of the expenses are given. Finally, a brief overview of the future activities is presented.

2002-01-01

478

Construction Progress of the Cooling and Ventilation in the LHC Project  

CERN Document Server

The Cooling and Ventilation Group has started the LHC construction work in September 1999 and will get into full activity when LEP will be stopped and dismantled: in total 12 major contracts for an amount of about 120 MCHF will be established to build the needed installations for the LHC. The author will report on the current works that are in progress on the different LEP Points distinguishing between the Ventilation and the Water Cooling installations. The Ventilation work, completed in the new surface buildings in Points 18, is currently held in Points 4 and 5. Point 1 will follow in the near future. The work for the Cooling plants comprehend the pumping stations, the cooling towers and the chilled water production stations in Points 1 and 5, the buried pipes in Points 1 and 4. For all of these activities, an updated report of the progress of the work, of the planning and of the expenses is given. Finally, a short ...

2001-01-01

479

Appendix B : Environment report : Securing a sustainable future for Canada`s oil sands industry  

Energy Technology Data Exchange (ETDEWEB)

The oil sands industry in Canada was said to be committed to environmentally sustainable economic development, i.e. a development that recognizes the mutual dependence of a healthy environment and a healthy economy. To indicate progress toward this goal, the report pointed out the investment of millions of dollars in environmental research and tens of millions of dollars in plant equipment already made. These infrastructure investments have paid dividends in terms of energy conservation, reduction of greenhouse gas emissions, land reclamation, air quality monitoring, water conservation, and water quality and biodiversity protection. A number of recommendations governing provincial jurisdictions over regulations were made. Particular concern was expressed over fairness, and overlapping of regulations by different levels of government.

1995-12-01

480

Advanced resin cleaning system  

International Nuclear Information System (INIS)

Novel and unprecedented ion exchange resin cleaning system, for use in BWR plants and featuring a vibration separator and basic design factors of Radiological Solutions, Inc., had been delivered to Tokai No. 2 Power Station, Japan Atomic Power Company, in October 2005. This compactly-designed system effectively separates crud and resin fines from ion exchange resins, with no clogging of separation screens. It generates minimized waste liquid and has a specially designed over-pack cleaning tank. The system has been in operation for about 2 years and half now and favorable operational data, such as crud and sulfate concentration decrease in feed water and reactor water respectively, and evaluation results have been reported from Japan Atomic Power Company and so on. (author)

2008-07-01

481

Environmentally assisted cracking in light water reactors. Semiannual report, October 1993--March 1994. Volume 18  

International Nuclear Information System (INIS)

This report summarizes work performed by Argonne National Laboratory (ANL) on fatigue and environmentally assisted cracking (EAC) in light water reactors (LWRs) during the six months from October 1993 to March 1994. EAC and fatigue of piping, pressure vessels, and core components in LWRs are important concerns in operating plants and as extended reactor lifetimes are envisaged. Topics that have been investigated include (a) fatigue of low-alloy steel used in piping, steam generators, and reactor pressure vessels, (b) EAC of wrought and cast austenitic stainless steels (SSs), and (c) radiation-induced segregation and irradiation-assisted stress corrosion cracking (IASCC) of Type 304 SS after accumulation of relatively high fluence. Fatigue tests have been conducted on A302-Gr B low-alloy steel to verify whether the current predictions of modest decreases of fatigue life in simulated pressurized water reactor ...

2007-09-01

482

Ecological sanitation: and sustainable sanitation system especially for poor and lowland countries  

International Nuclear Information System (INIS)

More than 80% of the people of Nepal are farmers and 90% of the farmers do farming for subsistence. Agricultural productions contribute about 50% of country's GDP. Agricultural sector has been categorized as the top priority sector since many years. The environment of the country has also deteriorated substantially by the unplanned and unscientific use of natural resources such as air, soil, water, air and forest. Fertility of the soil has also been declining and studies show that productions in mountains is decreasing at a rate of 40 Kg/ha. Yr (1). The Terai, a narrow strip of land in the south, is in heavy pressure due to over exploitation and population growth (both natural and migratory). Shallow groundwater (shallow tube wells) is the main source of drinking water in Terai (the lowland region of Nepal). A study conducted by Department of Water Supply and Sewerage (DWSS) showed that more than 55% of Terai tube wells are ...

2004-06-07

483

Aquatic macroinvertebrates and water quality of Sandia Canyon, Los Alamos National Laboratory, December 1992--October 1993. Status report  

International Nuclear Information System (INIS)

In the summer of 1990, an accidental spill from the TA-3 Power Plant Environment Tank released more than 3,785 liters of sulfuric acid into upper Sandia Canyon. The Biological Resource Evaluation Team (BRET) of EM-8 at Los Alamos National Laboratory (LANL) has collected aquatic samples from the stream within Sandia Canyon since then. These field studies gather water quality measurements and collect macroinvertebrates from permanent sampling sites. An earlier report by Bennett (1994) discusses previous BRET aquatic studies in Sandia Canyon. This report updates and expands Bennett's initial findings. During 1993, BRET collected water quality data and aquatic macroinvertebrates at five permanent stations within the canyon. The substrates of the upper three stations are largely sands and silts while the substrates of the two lower stations are largely rock and cobbles. The two upstream stations are located near outfalls that ...

2004-06-01

484

Radiological and Environmental Research Division: ecology. Annual report, January-December 1982  

Energy Technology Data Exchange (ETDEWEB)

This is the annual report of the Radiological and Environmental Division of the Argonne National Laboratory for 1982. Studies of the effects of ozone on crop growth and yield have been carried out by the Terrestrial Ecology Group for winter wheat and for sorghum. The Microcosms for Acid Rain Studies (MARS) facility was completed in the early summer. Controlled investigations of plant and soil responses in acid rain were initiated with crop plants grown in two different midwestern soil types. The Transuranics Group has found that the solubility and adsorptive behavior of plutonium previously observed at fallout concentrations in natural waters (approx. 10/sup -16/ to 10/sup -18/ M) is applicable at plutonium concentrations as high as 10/sup -8/ M. The Lake Michigan eutrophication model has been adapted to operation in a Monte Carlo mode. Simulations based on yearly phosphorus loadings and winter conditions were selected at ...

1983-09-01

485

Program plan for development of underground hydroelectric pumped storage technology  

Science.gov (United States)

The Underground Hydroelectric Pumped Storage (UHPS) Program Plan describes in detail the planned activities and expected accomplishments in the conduct of UHPS technology development and validation envisioned in the 1976 to 1990 time frame. This document describes the program objectives, implementation strategy, and management methodology. The concept of underground hydroelectric pumped storage is fully directed to application in the electric utility industry. This technology involves using electrical energy generated by base-load plants during off-peak load periods to drive a high-head pump/turbine which pumps water from a lower reservoir to a substantially elevated (upper) reservoir corresponding to a head of 1000 m or so. The upper reservoir is at ground level and the lower reservoir is below ground. Then, during peak-load periods, water in the upper reservoir is allowed to flow to the lower reservoir which, in turn, ...

1976-03-01

486

Hydroelectric power in Switzerland: large growth potential by increasing the installed power  

International Nuclear Information System (INIS)

Due to its important hydroelectric power generation facilities (about 525 plants with a total power of 13,314 MW producing about 35.3 TWh annually) Switzerland plays an important role in the interconnected European power system. Large artificial storage lakes in the Swiss Alps can generate peak power during hours of highest demand: 9700 MW are available from accumulated energy and the total power of pumped-storage facilities amounts to 1700 MW. The latter allow refilling the reservoirs at periods of low power demand and generating power at periods of peak demand. In the case of favorable conditions, the yearly average power production could be increased by 6% and the production during the winter period (October to March) by 20% by the year 2020. However, looking forward to the year 2050, the annual production is expected to decrease by 3% despite a possible extension of hydropower. This decrease is due to the enforcement of the minimum residual ...

487

Executive summary: Winter and spring water quality survey of acid mine drainage neutralization plants. Draft report  

Science.gov (United States)

On November 2, 1974, Skelly and Loy submitted recommendations to the United States Environmental Protection Agency concerning establishment of effluent limitations for the Coal Mining Point Source Category, culminating an exhaustive study of water treatment technology within the coal industry. Members of the National Coal Association alleged that the efficiency of acid mine drainage treatment plants and settling basins is seriously reduced during winter and spring seasons. The original study was conducted during the summer months, and review of historical seasonal effluent data indicated there may be validity to this claim. To validate and confirm the conclusions and proposed effluent limitations established in part from this historical data, a further sampling program was conducted during the winter and spring of 1975. This report presents the findings of that sampling program, and correlates previously collected sample data into a ...

1975-06-24

488

Effects of a mixture of tetracyclines to Lemna gibba and Myriophyllum sibiricum evaluated in aquatic microcosms  

Energy Technology Data Exchange (ETDEWEB)

The impact of a mixture of oxytetracycline, chlortetracycline, tetracycline and doxycycline on Myriophyllum sibiricum and Lemna gibba was investigated using fifteen 12,000-L microcosms (k = 5, n = 3). Significant concentration-response relationships were only found for M. sibiricum, where dry mass was 69, 47, 30, and 7% of controls at respective treatment concentrations of 0.080, 0.218, 0.668, and 2.289 {mu}mol/L. Somatic endpoints were strongly and negatively correlated with percent light transmission, except plant length, which was positively correlated. Treated microcosms experienced a reduction in the percent of surface irradiance penetrating the water column as high as 99.8% at a depth of 70 cm, relative to controls. Position relative to the water column was likely responsible for the differential effects observed between floating (L. gibba) and submerged (M. sibiricum) species of macrophytes. A hazard quotient ...

2005-12-15

489

Control of the reduction/oxidation potential of Hanford Waste Vitrification Plant feeds  

International Nuclear Information System (INIS)

A schematic diagram shows the various processing steps to be performed during feed preparation in the Hanford Waste Vitrification Plant (HWVP). The pretreated NCAW is transferred to the slurry receipt adjustment tank (SRAT) in the HWVP for concentration. Water removed during boildown is collected in the slurry mix evaporator condensate tank (SMECT). After waste treatment the water is returned to the storage tanks for eventual disposal. The pretreated Neutralized Current Acid Waste (NCAW) is concentrated in the SRAT to approximately 125 g waste oxides/ liter. Formic acid is then added at a controlled rate to improve rheological properties and achieve a required reduction/oxidation state. Reflux boiling is initiated and continued for several hours. The concentrated slurry is cooled and pumped to the slurry mix evaporator (SME). In the SME, glass frit is added, and the slurry is further concentrated to achieve a nominal ...

1988-09-11

490

Comparison of Measured and Predicted {sup 3}H Concentrations in Environmental Media around the Wolsung Site for the Validation of INDAC Code  

Energy Technology Data Exchange (ETDEWEB)

The predicted results of INDAC code were compared with measured {sup 3}H concentrations in air and pine-needle around the Wolsung site. The optimal sets of input data to INDAC were in addition selected by comparing the measured values with the predicted values of INDAC based on various conditions such as the release modes of effluents into the environment, the classification of wind classes, and the consideration of terrain. The predicted {sup 3}H concentrations in air and pine-needle were shown to have good agreement with measured values, although there are some limitations such as uncertainties in measured values, complex topology around the site, and the land-sea breeze effects. The assumption on the {sup 3}H behavior in vegetables or plants that the ratio of {sup 3}H concentration in plant water to {sup 3}H concentration in atmospheric water is 1/2 was shown to be conservative in terms of the audit ...

2000-06-15

491

Comparison of Measured and Predicted "3H Concentrations in Environmental Media around the Wolsung Site for the Validation of INDAC Code  

International Nuclear Information System (INIS)

The predicted results of INDAC code were compared with measured "3H concentrations in air and pine-needle around the Wolsung site. The optimal sets of input data to INDAC were in addition selected by comparing the measured values with the predicted values of INDAC based on various conditions such as the release modes of effluents into the environment, the classification of wind classes, and the consideration of terrain. The predicted "3H concentrations in air and pine-needle were shown to have good agreement with measured values, although there are some limitations such as uncertainties in measured values, complex topology around the site, and the land-sea breeze effects. The assumption on the "3H behavior in vegetables or plants that the ratio of "3H concentration in plant water to "3H concentration in atmospheric water is 1/2 was shown to be conservative in terms of the audit calculation performed by ...

2000-06-01

492

Behaviour of OFHC copper in highly pure water; Comportamento del rame OFHC in acqua di elevata purezza  

Energy Technology Data Exchange (ETDEWEB)

In order to gain a wider knowledge of corrosion phenomena in OFHC (oxygen free high conductivity) copper pipes of the stator cooling circuit of a power plant turboalternator, a research program was laid out which is based on the use of an experimental loop simulating real operating conditions as closely as possible. The samples examined were either copper foils or hollow conductors of the type that is normally used in the stator cooling system, and the circulating fluid was high purity water with controlled O/sub 2/, H/sub 2/ and C0/sub 2/ contents. Investigations were focused on the kinetics of O/sub 2/ removal through catalytic resins covered with metallic palladium (at different temperatures and pressures) and on the kinetics of CO/sub 2/ removal through mixed bed resins. Subsequently, attention was directed to the corrosion of copper (in the form of foils or hollow conductors) under different experimental conditions simulating either ...

1991-12-31

493

Anaerobic treatment of wastewater from a food-manufacturing plant with a low concentration of organic matter and regeneration of usable pure water  

Energy Technology Data Exchange (ETDEWEB)

Wastewater from a food-manufacturing plant with a low concentration of organic matter was treated at 37 centigrade in an anaerobic fluidized-bed reactor or in an upflow anaerobic sludge blanket. As the influent TOC (total organic carbon) concentration decreased, the TOC removal efficiency in these reactors decreased from 85% to 65%. The concentration of suspended solids in the effluent could be reduced to 20 mg/l, which corresponded to 7% of that in the influent. The effluent from both reactors was treated aerobically in a fixed-bed reactor. The TOC concentration and optical density of effluent from the aerobic treatment were reduced to 5 mg/l and 0.005, respectively. When the effluent treated anaerobically or aerobically was passed over an activated carbon column, the effluent TOC concentration was reduced to 2 to 3 mg/l. The conductivity in raw wastewater was remarkably reduced on an ion-exchange resin column. Ultra-pure water for industrial ...

1994-03-25

494

Advanced Neutron Source: Plant Design Requirements. Revision 4  

Energy Technology Data Exchange (ETDEWEB)

The Advanced Neutron Source will be a new world-class facility for research using hot, thermal, cold, and ultra-cold neutrons. The heart of the facility will be a 330-MW (fission), heavy-water cooled and heavy-water moderated reactor. The reactor will be housed in a central reactor building, with supporting equipment located in an adjoining reactor support building. An array of cold neutron guides will fan out into a large guide hall, housing about 30 neutron research stations. Appropriate office, laboratory, and shop facilities will be included to provide a complete facility for users. The ANS is scheduled to begin operation at the Oak Ridge National Laboratory early in the next decade. This PDR document defines the plant-level requirements for the design, construction, and operation of ANS. It also defines and provides input to the individual System Design Description (SDD) documents. Together, this PDR document and the ...

1990-07-01

495

/sup 252/Cf-source-driven neutron noise analysis method  

Energy Technology Data Exchange (ETDEWEB)

The /sup 252/Cf-source-driven neutron noise analysis method has been tested in a wide variety of experiments that have indicated the broad range of applicability of the method. The neutron multiplication factor k/sub eff/ has been satisfactorily detemined for a variety of materials including uranium metal, light water reactor fuel pins, fissile solutions, fuel plates in water, and interacting cylinders. For a uranyl nitrate solution tank which is typical of a fuel processing or reprocessing plant, the k/sub eff/ values were satisfactorily determined for values between 0.92 and 0.5 using a simple point kinetics interpretation of the experimental data. The short measurement times, in several cases as low as 1 min, have shown that the development of this method can lead to a practical subcriticality monitor for many in-plant applications. The further development of the method will require experiments ...

1985-01-01

496

Advanced applications of water cooled nuclear power plants  

International Nuclear Information System (INIS)

By August 2007, there were 438 nuclear power plants (NPPs) in operation worldwide, with a total capacity of 371.7 GW(e). Further, 31 units, totaling 24.1 GW(e), were under construction. During 2006 nuclear power produced 2659.7 billion kWh of electricity, which was 15.2% of the world's total. The vast majority of these plants use water-cooled reactors. Based on information provided by its Member States, the IAEA projects that nuclear power will grow significantly, producing between 2760 and 2810 billion kWh annually by 2010, between 3120 and 3840 billion kWh annually by 2020, and between 3325 and 5040 billion kWh annually by 2030. There are several reasons for these rising expectations for nuclear power: - Nuclear power's lengthening experience and good performance: The industry now has more than 12 000 reactor years of experience, and the global average nuclear plant availability during 2006 reached ...

2007-07-01

497

Advanced applications of water cooled nuclear power plants  

International Nuclear Information System (INIS)

By August 2007, there were 438 nuclear power plants (NPPs) in operation worldwide, with a total capacity of 371.7 GW(e). Further, 31 units, totaling 24.1 GW(e), were under construction. During 2006 nuclear power produced 2659.7 billion kWh of electricity, which was 15.2% of the world's total. The vast majority of these plants use water-cooled reactors. Based on information provided by its Member States, the IAEA projects that nuclear power will grow significantly, producing between 2760 and 2810 billion kWh annually by 2010, between 3120 and 3840 billion kWh annually by 2020, and between 3325 and 5040 billion kWh annually by 2030. There are several reasons for these rising expectations for nuclear power: - Nuclear power's lengthening experience and good performance: The industry now has more than 12 000 reactor years of experience, and the global average nuclear plant availability during 2006 reached ...

1996-07-21

498

Advanced applications of water cooled nuclear power plants  

International Nuclear Information System (INIS)

By August 2007, there were 438 nuclear power plants (NPPs) in operation worldwide, with a total capacity of 371.7 GW(e). Further, 31 units, totaling 24.1 GW(e), were under construction. During 2006 nuclear power produced 2659.7 billion kWh of electricity, which was 15.2% of the world's total. The vast majority of these plants use water-cooled reactors. Based on information provided by its Member States, the IAEA projects that nuclear power will grow significantly, producing between 2760 and 2810 billion kWh annually by 2010, between 3120 and 3840 billion kWh annually by 2020, and between 3325 and 5040 billion kWh annually by 2030. There are several reasons for these rising expectations for nuclear power: - Nuclear power's lengthening experience and good performance: The industry now has more than 12 000 reactor years of experience, and the global average nuclear plant availability during 2006 reached ...

2007-11-23

499

Annual Report 2007. Nuclear Regulatory Authority  

International Nuclear Information System (INIS)

The present Annual Report of Activities of the Nuclear Regulatory Authority (ARN), prepared regularly from the creation as independent institution, describes across tree parts and seven annexes the activities developed by the organism during 2007. The main topic are: the organization and the activity of the ARN; the regulatory standards; the licensing and inspection of nuclear power plants and critical facilities; the emergency systems; the occupational surveillance; the environmental monitoring; improved organizational. Also, this publication have annexes with the following content: regulatory documents; inspections to medical, industrial and training installations; regulatory guides; measurement and evaluation of the drinking water of Ezeiza.

2004-07-11

500

An investigation of the retention of some radioelements on natural fibers  

International Nuclear Information System (INIS)

The retention of radio-Eu, Go, Cs and Sr, at the tracer level, on raw fibers produced from hemp, linen and Jute plants was investigated. The study was conducted from different media including: sea and tap waters, sodium chloride and nitric acid solutions of different Ph. The percentage retention and elution, on prolonged contact, varied from one element to another depending on conditions. Extraction chromatography columns, using these fibers as supporting material were also experimented. Results were discussed together with possible applications. 7 tabs.