Energy Technology Data Exchange (ETDEWEB)
The purpose of the piezometer network is to establish baseline hydraulic head data for the water table aquifer at the F- and H-Area seeplines prior to startup of the groundwater extraction/injection remediation system.
1999-06-02
Remote monitoring of a coal waste impoundment in West Virginia. Open file report Oct 78-Sep 81
Energy Technology Data Exchange (ETDEWEB)
This report addresses remote monitoring of coal waste impoundments for stability. Existing automated geotechnical monitoring systems are described and reviewed along with details of instruments suitable for such systems. An impoundment in West Virginia, which was in the construction stage, was instrumented and monitored between July 1979 and May 1981. Sensors that measure surface and subsurface parameters including settlement, horizontal deflection, surface tilt, pore water pressure, seepage, pond level, and meteorlogical parameters were installed. Recommendations for improving and expanding the capabilities of the monitoring system are given.
1982-02-01
Annual Report for Gravity Collection Lysimeter Monitoring Plan - ERDF Cells 5 and 6
Energy Technology Data Exchange (ETDEWEB)
The data and analyses contained in this report reflect the initial characterization of construction and consolidation water in Cells 5 and 6 lysimeters. Therefore, the scope of this report will be to establish constituent levels and document dewatering activities completed to date.
2006-12-19
New monitoring system for microbiological control effectiveness on pitting corrosion of carbon steel
Energy Technology Data Exchange (ETDEWEB)
A new on-line monitoring system has been developed for pitting corrosion monitoring of carbon steel tubes in cooling water systems. This monitoring system was found to be quite sensitive to the microbiological activity relating to pitting corrosion on a real-time basis. The value of galvanic current indicates the performance level of pitting corrosion inhibition even in biocide application. In addition, the changes in the galvanic current provide indicative information about the effectiveness in microbiological control program, even when the pressure drop measurement indicates no biofilm formation. It can be also useful in detecting a microbiological control upset. In this paper, an introduction of the new monitoring system as a microbiological control effectiveness monitor and the field test results are discussed.
1997-12-01
Energy Technology Data Exchange (ETDEWEB)
In 2000, a network of twenty-three piezometers was used to measure hydraulic head in the water-table aquifer (Upper Aquifer Zone of the Upper Three Runs Aquifer, or UAZ of the UTRA) along the ground water outcrops (i.e. seeplines) near the F- and H-Areas.
2001-07-10
New intelligent monitor for CANDU type NPP
International Nuclear Information System (INIS)
Nuclear energy provides a third of Europe's electricity with nearly no greenhouse-gas emissions. Sustained efforts are now being conducted to harmonize regulations all over Europe through WENRA and to converge on technical nuclear safety practices within the TSO network ETSON (European Technical Safety Organizations Network). In CANDU type NPP the tritiated water occurs by the neutron bombardment of deuterium. The tritiated water vapors imply health hazard (in the critical organs of the body the water presents a 10 day average biological half-life) and the early detection in nuclear plants of tritium emissions is important because the tritiated water vapors have the same characteristics as of atmospheric water vapors. By detecting tritiated vapors, the monitoring system ensures the following objectives: (a) indicates levels of tritium ...
2009-10-12
Assessing vineyard water status using the reflectance based Water Index
British Library Electronic Table of Contents (United Kingdom)
In the Mediterranean arc, vines for wine production are mainly grown without the support of irrigation. Under such conditions, site variables affecting the extent and seasonal timing of water deficits are the dominant environmental constraints for grape production. Moreover, water availability and vine water status are the factors most comprehensively determining fruit composition and, thus, wine quality. Therefore, monitoring the extent of water stress in vines might be a valuable tool for the optimisation of grape yield and quality. The objective of this study was to evaluate the feasibility of using the reflectance based Water Index (WI) to estimate vine water status at the leaf and canopy levels. The study was conducted on Vitis vinifera cv. Chardonnay potted plants submitted to contra...
2010-01-01
International Nuclear Information System (INIS)
This paper presents an overview of issues related to surface water contamination arising from uranium mining activities in the Alligator Rivers Region (ARR) of northern Australia, and a program of research and monitoring that must assess the potential and actual effects on ecosystem and human health. The program of assessing effects on aquatic ecosystems involves a four-tiered approach including the derivation of local water quality guideline trigger values, direct toxicity assessment of mine waters prior to their release, creekside or in situ monitoring for early warning of adverse effects during mine water release, and longer-term monitoring of macroinvertebrate and fish communities. Bioaccumulation in aquatic biota is also assessed, and is an issue of importance not only to ecosystem health, but also to the health of local Aboriginal ...
2002-12-27
Contribution of climatic and anthropogenic effects to the hydric deficit of peatlands
British Library Electronic Table of Contents (United Kingdom)
Abstract The present study makes use of a detailed water balance to investigate the hydrological status of a peatland with a basal clay-rich layer overlying an aquifer exploited for drinking water. The aim is to determine the influence of climate and groundwater extraction on the water balance and water levels in the peatland. During the two-year period of monitoring, the hydrological functioning of the wetland showed a hydric deficit, associated with a permanent unsaturated layer and a deep water table. At the same time, a stream was observed serving as a recharge inflow instead of draining the peatland, as usually described in natural systems. Such conditions are not favourable for peat accumulation. Field investigations show that the clay layer has a high hydraulic conductivity (from 11...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Based on the IAPWS technical guidance on ''Instrumentation for Monitoring and Control of Cycle Chemistry for Steam-Water Circuits of Fossil-Fired and Combined Cycle Power Plants,'' the latest situation regarding instrumentation for nuclear power plants is discussed. As a result of the discussion, it is concluded that: (1) Reliable and safe operation of plants is established by the application of suitable chemical conditions in plant cooling systems, which should be supported by the selection of suitable control targets for monitoring and by the application of reliable instruments. (2) The minimum level of key instrumentation consists of on-line as well as off-line instruments for monitoring the key parameters: - on-line: pH, conductivity, cation conductivity, O{sub 2} and H{sub 2} concentrations, electrochemical corrosion potential; - off-line: ...
2010-05-15
In situ monitoring of grouted electrolytes
Energy Technology Data Exchange (ETDEWEB)
Cement-based composites are widely used in applications which demand long-term service life. One important example is in immobilization matrices for low-level radioactive and other hazardous wastes, which demands long-term retention and durability. The authors describe conductivity measurements of grouts flooded with water and in contact with a sink that consists of pure water. The conductivity measurements were designed and carried out in parallel with present quality verification methods and standard leach tests of the nuclear waste management industry. For the first time, the authors show that the method of replacing intrusive chemical analysis with conductivity measurements of the leaching samples yields equivalent results.
1996-04-01
Stability against temperature variations at the ALS
Energy Technology Data Exchange (ETDEWEB)
We have studied the effects of temperature fluctuations on the Advanced Light Source (ALS). By modeling the storage ring support structure, we find that fluctuations of {plus minus}2 to 3deg C in the tunnel will cause photon beam motion of the order of the beam size. Temperature stabilization at this level will allow the residual motion of the photon beams to be reduced by a second level of active feedback, operating on signals from photon beam position monitors. Air temperature in the experimental area and the temperature of cooling water serving the beamlines should be constant to {plus minus}1deg C. This will provide a suitable environment for experiments. (orig.).
1990-05-20
International Nuclear Information System (INIS)
During the first and second quarters of 1994 air samples were collected and analyzed from 54 air particulate/halogen sampling stations, 10 noble gas sampling stations and 19 tritiated water vapor sampling stations. Surface water samples were collected and analyzed from 12 open water supply reservoirs, 8 natural springs, 2 wastewater containment ponds and 9 sewage lagoons. Groundwater samples were obtained brom 10 potable and 1 non-potable supply wells, and 8 drinking water consumption points. Ambient radiation levels were measured at 193 locations.
1991-10-31
International Nuclear Information System (INIS)
The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 (16N) and Oxygen-19 (19O) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of 19O and 16N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high ambient radiation level even though sensitivity is appreciably good. For detector position in ...
2006-11-13
Pre-operational monitoring plan for LIL waste disposal at Saligny
International Nuclear Information System (INIS)
Developed under the PN II Project 71-009 - MONA, the pre-operational monitoring program of the LIL waste disposal site presented in this paper covers the main elements requested for a continuous improvement of site characterization and safety assessment, as well as for the set up of the baseline data requested for the future operational and post-operational monitoring and surveillance. These elements are: vadose and saturated zones hydrogeology, surface erosion, meteorology and radionuclides content in waters, soil and biota. Pairs of TDR (Time Domain Reflectometry) and pressure sensors, coupled with a meteorological station have been installed on site for the continuously measurement of the water content and matric potential changes due to the climate variations. The data will be used to follow the water balance, the pores water velocity and to calculate the ...
2009-10-12
International Nuclear Information System (INIS)
The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For detector position out side the RB containment, ...
2005-11-23
UARS Particle Environment Monitor (PEM) Level 3AT - Mirador - NASA
May 11, 2011 ... The Particle Environment Monitor (PEM) on NASA's Upper Atmosphere Research Satellite (UARS) measures the type, amount, energy, and ...
International Nuclear Information System (INIS)
Design improvements are being incorporated into the heavy water management systems at Wolsong 2,3 and 4 to reduce the load on the vapour recovery driers and upgraders and the heavy water losses via the stack. There will also be improvements to monitor heavy water and tritium releases. This paper describes the improvements, gives background on heavy water balance mechanism, the historical trends for heavy water recovery/losses and estimated dose to the member of the public critical group resulting from the airborne and waterborne releases. The measured tritium activity levels in the heat transport system (HTS) and moderator system at Wolsong 1 are given. Using these activity levels and heavy water loss data, tritium losses from the dried and ventilated areas are estimated. A qualitative assessment of ...
1994-03-01
British Library Electronic Table of Contents (United Kingdom)
Fourier-transform infrared (FTIR) spectroscopy was used to monitor amino acids, organic acids, and changes during ripening. Twelve Cheddar cheese samples were ripened for 73 days and samples were drawn periodically. Water-soluble fractions of samples were analyzed by gas chromatography (20 amino acids), liquid chromatography (three organic acids), and FTIR spectroscopy (4000-700 cm-1). Spectra were correlated with chromatographic data and ripening events and analyzed by multivariate statistics to develop prediction and classification models. Most models showed a good fit (correlation coefficient > or =0.89) and could predict the levels of amino acids and organic acids and age of the cheese in less than 20 min. Lactic acid, leucine, glutamic acid, asparagine, phenylalanine, and valine were ...
2011-01-01
Development of safety function assessment trees for pressurized heavy water reactor LP/SD operations
Energy Technology Data Exchange (ETDEWEB)
The objective of Configuration Risk Management Program(CRMP) is to maintain the safety level by assuring the defense-in-depth of nuclear power plant while the configurations are changed during plant operations, especially for the LP/SD. Such a safety purpose can be achieved by establishing the risk monitoring programs with both quantitative and qualitative features. Generally, the quantitative risk evaluation models, i.e., PRA models are used for the risk evaluation during full power operation, and the qualitative risk evaluation models such as safety function assessment trees are used. Through this study, safety function assessment trees were developed.
2003-10-01
As part of its long-term control plan for combined sewer overflow (CSO) abatement, the city of Buffalo, New York, maintained a network of Hydrolab Datasondes (Hydrolab-Hach Company, Loveland, Colorado) to assess receiving water-quality effects by continuously logging dissolved oxygen, pH, temperature, conductivity, and turbidity. Although the effect of individual CSOs could be visualized, turbidity levels entering the Buffalo River from the upper watershed often were greater than from CSO discharges. Turbidity data showed that the Buffalo River was a net-sediment sink. Low dissolved oxygen levels were observed in the summer during dry weather, baseflow, and watershed-wide storms and CSO events. Some CSOs did not produce dissolved oxygen sags in the receiving waters, but others did. This information, together with the sampling done for organic and inorganic contaminants, can aid the decisionmaking ...
Regulation of sucrose synthesis in water stressed leaves
Energy Technology Data Exchange (ETDEWEB)
Alteration in carbon metabolism and carbohydrate partitioning occur in drought stressed plants. Some species accumulate large quantities of starch in the chloroplast, which may be used to support sucrose synthesis under conditions of limited carbon supply. The authors monitored chemical partitioning of carbon between sugars and starch and the activity of sucrose phosphate synthase (SPS) and fructose 1,6 bisphosphatase (FBPase) in the source leaves of water stressed tomatoes. Plants were stressed by withdrawing water for 10 days and rewatered for recovery. Water potential dropped from {minus}0.8 to {minus}2.2MPA in 10 days, but recovered to control level 2 days after rewatering. Photosynthetic rates as measured by the activity of Rubisco followed similar patterns to those of water potential. After 10 days, leaf starch levels decreased to less ...
1991-05-01
Remote control monitoring - a review of the latest equipment
Energy Technology Data Exchange (ETDEWEB)
This article reviews briefly a range of the latest monitoring and controlling equipment for use in coal mines. This includes pressure transmitters, shale/coal discriminator, nucleonic bunker level indicator, automatic steering and monitoring system, oscilloscope/multimeter, and microprocessor based digital display controllers. 1 fig.
1988-01-01
Computerised, remote monitoring systems for underground coal mines
Energy Technology Data Exchange (ETDEWEB)
This report presents a study on the use of computerised, continuous remote monitoring systems for fire and explosive atmosphere safety in underground coal mines. The effects of these systems on the safety level in mines are investigated, and the relationship between mine safety regulations and computerised, continuous, remote monitoring is analysed.
1983-03-01
Phipps Bend Nuclear Plant construction effects monitoring report, October 19, 1978-October 18, 1979
International Nuclear Information System (INIS)
The aquatic monitoring program consists of onsite monitoring of surface runoff, monitoring of point source discharges identified in the NPDES permit, and limited instream biological monitoring. The program is tied to a feedback mechanism for implementing corrective action before significant adverse impacts occur in the Holston River. This report evaluates the aquatic monitoring program for the second year (October 19, 1978 through October 18, 1979) of construction as required by the NPDES permit, Part III, Section I. Included in this report are data from peripheral runoff monitoring, selected heavy rainfall sampling, ground water monitoring, instream aquatic macroinvertebrate monitoring, and aquatic macrophyte monitoring.
Environmental monitoring data were collected at and around the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) at the Nevada Test Site. These data are associated with radiation exposure, air, groundwater, meteorology, vadose zone, subsidence, and biota. This report summarizes the 2006 environmental data to provide an overall evaluation of RWMS performance and to support environmental compliance and performance assessment (PA) activities. Some of these data (e.g., radiation exposure, air, and groundwater) are presented in other reports (U.S. Department of Energy, 2006; Warren and Grossman, 2007; National Security Technologies, LLC, 2007). Direct radiation monitoring data indicate that exposure levels around the RWMSs are at or below background levels. Air monitoring data at the Area 3 and Area 5 RWMSs indicate that tritium concentrations are slightly above background ...
2007-06-30
Appendix B : Environment report : Securing a sustainable future for Canada`s oil sands industry
Energy Technology Data Exchange (ETDEWEB)
The oil sands industry in Canada was said to be committed to environmentally sustainable economic development, i.e. a development that recognizes the mutual dependence of a healthy environment and a healthy economy. To indicate progress toward this goal, the report pointed out the investment of millions of dollars in environmental research and tens of millions of dollars in plant equipment already made. These infrastructure investments have paid dividends in terms of energy conservation, reduction of greenhouse gas emissions, land reclamation, air quality monitoring, water conservation, and water quality and biodiversity protection. A number of recommendations governing provincial jurisdictions over regulations were made. Particular concern was expressed over fairness, and overlapping of regulations by different levels of government.
1995-12-01
International Nuclear Information System (INIS)
The release of any potential radioactive pollutant to the environment during routine operation of a Nuclear Power Plant should be the subject of appropriate controls and assessments. It is impossible to monitor directly the dose contribution of normal releases because the environmental radioactivity levels are very small but source monitoring provides a means of assessing the radiation exposure of population groups, critical groups and individual members of the public. Derived emissions limits ( DELs ) are used to quantify the relationship between releases of radioactivity and doses to public - critical groups. CNE Cernavoda DELs are based on a pathway analysis conducted for Cernavoda site specific conditions and they were computed using a compartment transfer model. Annual air and water emissions for the most significant radionuclides between 1997 and 2008 are presented in terms of doses and can be ...
2009-10-12
Measurements of radon concentration levels in drinking water at urban area of Curitiba, Brazil
International Nuclear Information System (INIS)
Current work presents the results of more than 100 measurements of 222Rn activity in drinking water collected at artesian bores at Curitiba region during the period of 2008 - 2009. The measurements were performed at the Laboratory of Applied Nuclear Physics of the Federal University of Technology in cooperation with the Nuclear Technology Development Center (CDTN) of Brazilian Nuclear Energy Committee (CNEN). Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specific kit of glass vessels Aqua KIT through the air pump. The equipment was adjusted with air flow of 0.5 L/min. The 222Rn concentration levels were detected and analyzed by the computer every 10 minutes using the software DataEXPERT by GENITRON Instruments. Collected average levels of 222Rn concentration were processed taking into account the volume of water sample and its temperature, ...
Contingency interim measure for the public water supply at Barnes, Kansas.
Energy Technology Data Exchange (ETDEWEB)
This document presents a conceptual design for a contingency interim measure (IM) for treatment of the public water supply system at Barnes, Kansas, should this become necessary. The aquifer that serves the public water supply system at Barnes has been affected by trace to low concentrations of carbon tetrachloride and its degradation product, chloroform. Investigations conducted on behalf of the CCC/USDA by Argonne National Laboratory (Argonne 2008a) have demonstrated that groundwater at the Barnes site is contaminated with carbon tetrachloride at concentrations exceeding the Kansas Tier 2 risk-based screening level (RBSL) and the EPA maximum contaminant level (MCL) of 5.0 {micro}g/L for this compound. The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) formerly operated a grain storage facility in Barnes, approximately 800 ft east-southeast of the public ...
2009-07-09
Energy Technology Data Exchange (ETDEWEB)
This report describes modelling where the hydrological modelling system MIKE SHE has been used to describe surface hydrology, near-surface hydrogeology, advective transport mechanisms, and the contact between groundwater and surface water within the SKB site investigation area at Laxemar. In the MIKE SHE system, surface water flow is described with the one-dimensional modelling tool MIKE 11, which is fully and dynamically integrated with the groundwater flow module in MIKE SHE. In early 2008, a supplementary data set will be available and a process of updating, rebuilding and calibrating the MIKE SHE model based on this data set will start. Before the calibration on the new data begins, it is important to gather as much knowledge as possible on calibration methods, and to identify critical calibration parameters and areas within the model that require special attention. In this project, the MIKE SHE model has been further developed. The model ...
2007-11-15
Needs and opportunities for monitoring corrosion
International Nuclear Information System (INIS)
Various electrochemical techniques are available to continuously monitor corrosion in conditions simulating those on the secondary side of PWR steam generators. This paper reviews those electrochemical techniques which are potentially useful to measure denting in tube-support crevices in situ. Attention is also given to corollary needs for monitoring the water chemistry which leads to corrosive attack. Finally some suggestions are offered for corrosion monitoring in autoclaves, model boilers and operating steam generators.
1985-03-01
Sea-to-sky airshed ambient quality monitoring report : 1984-2001
Energy Technology Data Exchange (ETDEWEB)
This report provides information to government and industry to enable decision-making and management of local environmental quality conditions. The need for a summary air quality report has arisen in recent years due to growing concerns about air quality. Increased growth in population and the tourism industry is placing additional pressures on environmental quality. The report summarized meteorological and air quality data collected by the British Columbia Ministry of Water, Land and Air Protection in the Sea-to-Sky airshed from 1984 to 2001. The airshed is located in the Lower Mainland region of British Columbia. Air quality monitoring was conducted for various periods at 18 different stations and meteorological monitoring was conducted at 4 locations. A list of both provincial and national air quality objectives and standards was provided, with definitions and reference levels from the Canadian ...
2004-09-01
Energy Technology Data Exchange (ETDEWEB)
In embodiments, spectroscopic monitor monitors modulated light signals to detect low levels of contaminants and other compounds in the presence of background interference. The monitor uses a spectrometer that includes a transmissive modulator capable of causing different frequency ranges to move onto and off of the detector. The different ranges can include those with the desired signal and those selected to subtract background contributions from those with the desired signal. Embodiments of the system are particularly useful for monitoring metal concentrations in combustion effluent.
2003-01-01
Wildlife Monitoring Program Plan - NASA Technical Report Server (NTRS)
Wildlife Monitoring System Schematic .......................... 40 ...... sentinel species - healthy fish are placed in an environment of water (where they arc not .... The way ir! which data for the fnre mdor study groups will be gathered tor managciacilt ...... Earth Resources Aircraft Program (ERAP) Camera ...
Distribution of polycyclic aromatic hydrocarbons in water and surface sediments from Daya Bay, China
International Nuclear Information System (INIS)
Findings indicate an urgent need to establish a monitoring program for persistent organic pollutants in water and sediment. - Marine culture is thriving in China and represents a major component of the regional economy in coastal zones, yet the environmental quality of many of those areas has never been studied. This paper attempts to investigate the quality status of Daya Bay, a key aquaculture area in China. The levels of 16 polycyclic aromatic hydrocarbons (PAHs) were determined in water and sediment samples of the bay. The total concentrations of 16 PAHs varied from 4228 to 29325 ng l"-"1 in water, and from 115 to 1134 ng g"-"1 dry weight in sediments. In comparison to many other marine systems studied, the PAH levels in Daya Bay waters were relatively high, and at six sites they were sufficiently high (>10 #mu#g l"-"1) to cause acute ...
2003-02-01
Energy Technology Data Exchange (ETDEWEB)
Within the framework of the MINEO research project assisted by the European Union the Deutsche Steinkohle AG (DSK) has developed methods for the operational use of remote sensing data and geo-information systems for the regular observation, measurement and evaluation of environmental effects in mining areas. Only indirect environmental effects of the mining industry, which may result in particular from subsidence-induced changes in the hydrological situation (ground water level, drainage) and the resulting effects on the vegetation and land utilisation, can be observed for the DSK test area 'Kirchheller Heide' because of the underground mine workings. Hence the evaluations of the remote sensing data were concentrated on the development of methods to measure and analyse the vegetation condition and any changes. MINEO thus constitutes a module for the DSK environmental information system. (orig.)
2005-10-20
Combining innovative technology demonstrations with dense nonaqueous phase liquids cleanup
Energy Technology Data Exchange (ETDEWEB)
Radioactively contaminated acidic aqueous wastes and organic liquids were discharged to the soil column at three disposal sites within the 200 West Area of the Hanford Site, Washington. As a result, a portion of the underlying groundwater is contaminated with carbon tetrachloride several orders of magnitude above the maximum contaminant level accepted for a drinking water supply. Treatability testing and cleanup actions have been initiated to remove the contamination from both the unsaturated soils to minimize further groundwater contamination and the groundwater itself. To expedite cleanup, innovative technologies for (1) drilling, (2) site characterization, (3) monitoring, (4) well field development, and (5) contaminant treatment are being demonstrated and subsequently used where possible to improve the rates and cost savings associated with the removal of carbon tetrachloride from the soils and groundwater.
1993-05-01
UK PubMed Central (United Kingdom)
BackgroundClinical experience with the continuous glucose monitoring systems (CGMS) is limited in Korea. The objective of this study is to evaluate the accuracy of the CGMS and the...Full Text Available
2010-12-01
Chalk Point cooling tower project native vegetation study. Final report 1979
The Potomac Electric Power Company generating station at Chalk Point, MD, utilizes brackish water in its natural draft cooling tower and, consequently, releases saline aerosol into the atmosphere. A research and monitoring project was established in 1974 to evaluate the effects of this drift on native perennial vegetation. Leaf samples have been collected form dogwood, Cornys florida, Virginia pine, Pinus virginiana, black locust, Robinia pseudoacacia, and sassafras, Sassafras albidum, located at 12 different sites in the vicinity of the power plant. Sampling was begun prior to the operation of the cooling tower, 1974, and continued through 1978. Complete results from monthly monitoring of foliar chloride in the four native tree species is documented for May through September 1978. Results from salt spray experiments indicate chloride and sodium concentrations in the wood of dogwood trees increases with increased spraying ...
1979-06-01
Energy Technology Data Exchange (ETDEWEB)
Long-Range Alpha Detector (LRAD) systems are designed to monitor alpha contamination by measuring the number of ions in the air. Alpha particles are a form of ionizing radiation and a typical 5-MeV alpha particle will create about 150,000 ion pairs in air. Field tests at various DOE sites have shown that LRAD Surface Soil Monitors (SSM), Sample Monitors, and Object Monitors are faster and more sensitive than traditional alpha detectors for measuring alpha contamination. This paper discusses the various applications of LRAD technology to low-level radioactive waste management.
1993-12-01
F-Area Seepage Basins groundwater monitoring report -- third and fourth quarters 1993. Volume 1
Energy Technology Data Exchange (ETDEWEB)
During the second half of 1993, the groundwater at the F-Area Seepage Basins (FASB) was monitored in compliance with Module 3, Section C, of South Carolina Hazardous Waste Permit SC1-890-008-989, effective November 2, 1992. The monitoring well network is composed of 87 FSB wells screened in the three hydrostratigraphic units that make up the uppermost aquifer beneath the FASB. A detailed description of the uppermost aquifer is included in the Resource Conservation and Recovery Act Part B post-closure care permit application for the F-Area Hazardous Waste Management Facility submitted to the South Carolina Department of Health and Environmental Control (SCDHEC) in December 1990. Beginning in the first quarter of 1993, the standard for comparison became the SCDHEC Groundwater Protection Standard (GWPS) specified in the approved F-Area Seepage Basins Part B permit. Currently and historically, gross alpha, nitrate, nonvolatile beta, and tritium are ...
1994-03-01
Energy Technology Data Exchange (ETDEWEB)
Volume 2 of the water resources data for the 1992 water year for Oklahoma consists of record of stage, discharge, and water quality of streams; stage, contents, and water quality of lakes or reservoirs; and water levels of ground-water well. The report contains discharge records for 136 gaging stations; stage and contents for 31 lakes or reservoirs; water quality for 50 gaging stations. Also included are 61 partial-record or miscellaneous streamflow stations and 28 ground-water sites.
1993-04-01
Design of automatic monitoring network for the water quality management of river basin
Energy Technology Data Exchange (ETDEWEB)
In designing automatic water quality monitoring networks for a river basin, determination of measurement locations and items is critical to the effectiveness of the total system. In this paper we studied how to decide these two design factors when a monitoring network is designed for the purpose of water quality surveillance and emergency alarm. For measurement locations, candidate sites are chosen based on the intake amount for water supply and the point sources of contamination. Then, detailed locations are decided according to the contaminant flow distance. As for measurement items, characteristics and the accident history of water pollution in the basin must be taken into account. Considering economic aspects, we proposed a two-stage measurement plan: basic components for all locations and selective ones variable for different locations. Proposed methodology ...
1996-04-30
UARS PEM Level 2 VMAG AC - Mirador - NASA
May 11, 2011 ... The Particle Environment Monitor (PEM) on NASA's Upper Atmosphere Research Satellite (UARS) measures the type, amount, energy, and ...
Optical Diffraction Studies of Muscle Fibers
UK PubMed Central (United Kingdom)
A new technique to monitor light diffraction patterns electrically is applied to frog semitendinosus muscle fibers at various levels of stretch. The intensity of the diffraction lines, sarcomere length...Full Text Available
1973-09-01
Remote sensing for environmental monitoring and resource management. Volume 2
Energy Technology Data Exchange (ETDEWEB)
The subject of this volume is remote sensing for environmental monitoring and resource management. This session is divided in eight parts. First part is on general topics, methodology and meteorology. Second part is on geology, environment and land cover. Third part is on disaster monitoring. Fourth part is on operational status of remote sensing. Fifth part is on coastal zones and inland waters. Sixth and seventh parts are on forestry and agriculture. Eighth part is on instrumentation and systems. (A.B.). refs., figs., tabs.
1992-12-31
Eielson Air Force Base Operable Unit 2 baseline risk assessment
Energy Technology Data Exchange (ETDEWEB)
Operable Unit 2 at Eielson Air Force Base (AFB) near Fairbanks, is one of several operable units characterized by petroleum, oil, and lubricant contamination, and by the presence of organic products floating at the water table, as a result of Air Force operations since the 1940s. The base is approximately 19,270 acres in size, and comprises the areas for military operations and a residential neighborhood for military dependents. Within Operable Unit 2, there are seven source areas. These source areas were grouped together primarily because of the contaminants released and hence are not necessarily in geographical proximity. Source area ST10 includes a surface water body (Hardfill Lake) next to a fuel spill area. The primary constituents of concern for human health include benzene, toluene, ethylbenzene, and xylenes (BTEX). Monitored data showed these volatile constituents to be present in groundwater wells. The data also ...
1994-10-01
Waste sampling and characterization facility (WSCF)
Energy Technology Data Exchange (ETDEWEB)
The Waste Sampling and Characterization Facility (WSCF) complex consists of the main structure (WSCF) and four support structures located in the 600 Area of the Hanford site east of the 200 West area and south of the Hanford Meterology Station. WSCF is to be used for low level sample analysis, less than 2 mRem. The Laboratory features state-of-the-art analytical and low level radiological counting equipment for gaseous, soil, and liquid sample analysis. In particular, this facility is to be used to perform Resource Conservation and Recovery Act (RCRA) of 1976 and Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) of 1980 sample analysis in accordance with U.S. Environmental Protection Agency Protocols, room air and stack monitoring sample analysis, waste water treatment process support, and contractor laboratory quality assurance checks. The samples to be analyzed contain ...
1994-10-01
Energy Technology Data Exchange (ETDEWEB)
Water-resources data for the 1993 water year for Minnesota consists of records of stage, discharge and water quality of streams; stage, contents, and water quality of lakes and reservoirs; and water levels and water quality in wells and springs. This volume contains discharge records for 58 gaging stations; stage and contents for 9 lakes and reservoirs; water quality 15 stream stations, 1 lakes station, 1 precipitation station, and water levels for 15 observation wells. Also included are 61 high-flow partial-record stations. Additional water data were collected at various sites, not part of the systematic data collection program and are pulished as miscellaneous measurements.
1994-07-01
Energy Technology Data Exchange (ETDEWEB)
Water-resources data for the 1991 water year for Minnesota consist of records of stage, discharge and water quality of streams; stage, contents, and water quality of lakes and reservoirs; and water levels and water quality in wells and springs. The volume contains discharge records for 60 gaging stations; stage and contents for 9 lakes and reservoirs; water quality for 18 stream stations, 1 lake station, 22 partial-record sites, 1 precipitation station, 108 wells; and water levels for 119 observation wells. Also included are 59 high-flow partial-record stations. Additional water data were collected at various sites, not part of the systematic data collection program and are published as miscellaneous measurements or low-flow investigations.
1992-09-01
Energy Technology Data Exchange (ETDEWEB)
The Tennessee Valley Authority (TVA), the Electric Power Research Institute (EPRI), and the Department of Energy-National Energy Technologies Laboratory (DOE-NETL) are evaluating and demonstrating integration of terrestrial carbon sequestration techniques at a coal-fired electric power plant through the use of Flue Gas Desulfurization (FGD) system gypsum as a soil amendment and mulch, and coal fly ash pond process water for periodic irrigation. From January to March 2002, the Project Team initiated the construction of a 40 ha Carbon Capture and Water Emissions Treatment System (CCWESTRS) near TVA's Paradise Fossil Plant on marginally reclaimed surface coal mine lands in Kentucky. The CCWESTRS is growing commercial grade trees and cover crops and is expected to sequester 1.5-2.0 MT/ha carbon per year over a 20-year period. The concept could be used to meet a portion of the timber industry's needs while simultaneously ...
2005-08-30
Changes in inflammatory mediators in experimental periodontitis in the rhesus monkey.
UK PubMed Central (United Kingdom)
Ligature-induced periodontitis was monitored for 6 months in eight Macaca mulatta monkeys to examine clinical status, radiographic bone level, and crevicular fluid (CF) levels of prostaglandin E2 (PGE2),...Full Text Available
1993-04-01
Energy Technology Data Exchange (ETDEWEB)
The EMP consists of a Compliance Monitoring Sampling Program and a Supplemental monitoring Sampling Program. The Compliance Monitoring Sampling Program will be conducted during a summer and a winter Baseline periods during the Pre-Construction/Construction phases of the Project and during a summer and a winter period following the successful Startup and Operational phase of the completed Project. compliance monitoring consist of conducting all the sampling and observation programs associated with existing required Federal, State, and Local Regulations, Permits and Orders. These include air, water, and waste monitoring and OSHA and NESHAP monitoring. The Supplemental Monitoring Program will also be conducted during a summer and a winter Baseline periods during the Pre-Construction/Construction phases of the Demonstration ...
1992-09-21
Groundwater surveillance plan for the Oak Ridge Reservation
Energy Technology Data Exchange (ETDEWEB)
US Department of Energy (DOE) Order 5400.1 requires the preparation of environmental monitoring plans and implementation of environmental monitoring programs for all DOE facilities. The order identifies two distinct components of environmental monitoring, namely effluent monitoring and environmental surveillance. In general, effluent monitoring has the objectives of characterizing contaminants and demonstrating compliance with applicable standards and permit requirements, whereas environmental surveillance has the broader objective of monitoring the effects of DOE activities on on- and off-site environmental and natural resources. The purpose of this document is to support the Environmental Monitoring Plan for the Oak Ridge Reservation (ORR) by describing the groundwater component of the environmental surveillance program for the DOE ...
1994-07-01
Energy Technology Data Exchange (ETDEWEB)
Ground-water monitoring near the Raft River site was initiated in 1974 by the IDWR. This effort consisted of semiannual chemical sampling of 22 irrigation wells near the Raft River geothermal development area. This program yielded useful baseline chemical data; however, several problems were inherent. For example, access to water pumped from the wells is limited to the irrigation season (April through September). All the wells are not continuously pumped; thus, some wells that are sampled one season cannot be sampled the next. In addition, information on well construction, completion, and production is often unreliable or not available. These data are to be supplemented by establishing a series of monitor wells in the proposed geothermal withdrawal and injection area. These wells were to be located and designed to provide data necessary for evaluating and predicting the impact of geothermal development ...
1982-09-01
MTF ' MISSISSIPPI SOUND REMOTE SENSING STUDY I 19 SEPTEMBER 1972
metric temperatures has been prepared showing the surface water temper- ... occasion, gray levels show different densities for similar water temper- ...
Energy Technology Data Exchange (ETDEWEB)
The Coastal Zone Sector of the Canadian Climate Impact and Adaptation Research Network (C-CIARN) was established to address concerns regarding climate change in coastal areas. Coastal zones are sensitive to increases in air, sea and ground temperatures as well as to variations in sea level, precipitation, ice thickness, and storm intensity. This report presents the results of a workshop which focused on how coastal communities will be affected by climate induced water level changes, particularly sea-level rise on ocean coasts and decreasing lake levels in the Great Lakes. The workshop addressed issues such as the effects of changing water levels on coastal infrastructure, utilities, community development, and the implications of changing water levels to human safety, cultural resources, tourism, and ...
2004-07-01
Energy Technology Data Exchange (ETDEWEB)
This report is a compilation of the calendar year 2003 groundwater sampling results from the Area 5 Radioactive Waste Management Site, Nevada Test Site. Wells Ue5PW-1, Ue5PW-2, and Ue5PW-3 were sampled semi-annually for the required analytes: pH, specific conductance, total organic carbon (TOC), total organic halides (TOX), tritium, and major cations/anions. Results from all samples collected in 2003 were within established criteria. These data indicate that there has been no measurable impact to the uppermost aquifer from the Resource Conservation and Recovery Act (RCRA) regulated unit within the Area 5 Radioactive Waste Management Site and confirm that any previous detections of TOC and TOX were false positives. Contamination indicator data are presented in control chart and tabular form with investigation levels indicated. Gross water chemistry data are presented in graphical and tabular form. There were no major changes noted in the ...
2004-02-01
Individual Radiation Protection Monitoring in the Marshall Islands: Rongelap Atoll (2002-2004)
Energy Technology Data Exchange (ETDEWEB)
The United States Department of Energy (U.S. DOE) has recently implemented a series of strategic initiatives to address long-term radiological surveillance needs at former U.S. nuclear test sites in the Marshall Islands. The plan is to engage local atoll communities in developing shared responsibilities for implementing radiation protection monitoring programs for resettled and resettling populations in the northern Marshall Islands. Using the pooled resources of the U.S. DOE and local atoll governments, individual radiological surveillance programs have been developed in whole body counting and plutonium urinalysis in order to accurately assess radiation doses resulting from the ingestion and uptake of fallout radionuclides contained in locally grown foods. Permanent whole body counting facilities have been established at three separate locations in the Marshall Islands including Rongelap Atoll (Figure 1). These facilities are operated and maintained by ...
2006-01-17
Building a Construction Curriculum for Your School District
Embracing the notion of going green, an affluent school district in Pennsylvania spent $83 million as part of the high school's renovation and expansion project. The three-level addition is now equipped with self-dimming lights, energy-efficient windows, a rooftop solar water heater, and a geothermal cooling and heating system. As a bonus for going green, the school district received a $250,000 grant from the Pennsylvania Department of Environmental Protection. The district used that money to create an information center in the lobby of the building where a touch-screen computer provides students, staff, and visitors with data related to the operation of the school's energy-efficient water and electrical systems. The system will graphically depict utility use over the course of a year. The monitoring system and touch-screen computer can turn this school into a living lab, with science, math, and ...
2010-06-01
Energy Technology Data Exchange (ETDEWEB)
To monitor the groundwater contamination and the effectiveness of remedial actions, over a thousand monitoring wells are in active operation (i.e., require quarterly or semi-annual sampling) at SRS. Most wells are expected to continue in operation for another 20 to 40 more years. Required sample volumes can range from a less than a liter to 10 liters. To support the long-term groundwater monitoring requirements of these wells, SRS actively seeks technologies that can maximize data acquisition and minimize costs. To meet this end, SRS has implemented the Purge Water Management System (PWMS). The key attributes of this system lie in its ability to reduce or eliminate the generation of purged groundwater, which is costly in terms of the time and management.
2004-02-10
Feedwater control device for a reactor
International Nuclear Information System (INIS)
Purpose: To stably control the reactor water level so as not to cause excess water feeding in a BWR type reactor. Constitution: A flow control valve is disposed to the exit of a feedwater pump for a nuclear reactor and the valve is controlled by a flow regulator to maintain the water level constant in the reactor. A signal from a water level controller is inputted to the flow regulator to thereby control the flow rate control valve. In this case, the flow regulator remains in a saturated state just after the starting of the feedwater pump, in which the pump flowrate is at 100% to result in an excess water feeding condition. In view of the above, a feedback circuit is provided to the flow regulator so that the saturated state is eliminated and the water feeding can be controlled directly from the ...
1981-11-12
Innovative coke oven gas cleaning system for retrofit applications
Energy Technology Data Exchange (ETDEWEB)
The EMP consists of a Compliance Monitoring Sampling Program and a Supplemental monitoring Sampling Program. The Compliance Monitoring Sampling Program will be conducted during a summer and a winter Baseline periods during the Pre-Construction/Construction phases of the Project and during a summer and a winter period following the successful Startup and Operational phase of the completed Project. compliance monitoring consist of conducting all the sampling and observation programs associated with existing required Federal, State, and Local Regulations, Permits and Orders. These include air, water, and waste monitoring and OSHA and NESHAP monitoring. The Supplemental Monitoring Program will also be conducted during a summer and a winter Baseline periods during the Pre-Construction/Construction phases of the Demonstration ...
1992-09-21
The relationship between plasma testosterone levels and locomotor activity in wild-caught sexually mature male meadow voles (Microtus pennsylvanicus) was assessed in the laboratory. Several aspects of locomotor activity were monitored for 1 h on two consecutive days using the automated Digiscan activity monitoring system. Plasma testosterone levels were determined immediately following the second day of activity monitoring. Significant Pearson correlations were obtained between plasma testosterone levels and total distance traveled [r(10) = 0.55, p < 0.05] and amount of time spent in movement [r(10) - 0.55, p < 0.05] on the second day. The wild voles showed a reduction in activity levels from the first to the second day of activity monitoring, which is indicative of habituation to a novel environment. This study ...
1998-04-01
Energy Technology Data Exchange (ETDEWEB)
The WIT telemanagement system simply, reliably and efficient by makes available to us in real time processed, ordered and managed data. Such information has been used to optimise the performance of the drinking water distribution networks on a number of housing estates. This has led to major saving in consumption and on equipment maintenance, thereby improving customer service and obtaining a more rational use of piped water. (Author)
1997-04-01
British Library Electronic Table of Contents (United Kingdom)
Ways of improving the water chemistry used in the turbine generator stator?s cooling systems at Russian nuclear power plants are considered. Data obtained from operational chemical monitoring of indicators characterizing the quality of cooling water in the turbine generator stator cooling systems of operating power units at nuclear power plants are presented.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
THMs are disinfection by-products (DBPs) generated during water chlorination. Concentration of individual and total THMs, depends on treatment process and THMs precursors level. ATLL water utility has two DWTP (Llobregar and Ter) that produce and supply drinking water to Barcelona and regional area. This work studies the levels of THMs along the ATLL distribution system (450 km). Although, no differences were observed along water pipes system, changes of water resource and mix procedures were related. (Author) 12 refs.
1999-07-01
Radon in soil gas survey in Curitiba (Brazil)
International Nuclear Information System (INIS)
This work describes the radon in soil gas measurements performed during the last two years in cooperation between the Laboratory of Applied Nuclear Physics of the Federal University of Technology (UTFPR), the Nuclear Technology Development Center (CDTN) and the Institute of Radiation Protection and Dosimetry (IRD) from the Brazilian Nuclear Energy Commission (CNEN). Following previously concluded measurements of radon concentration in dwellings and the measurements of 222Rn activity in drinking water collected at artesian bores of Curitiba urban area, present step of activities has been dedicated to measurements of radon concentration in soil gas. Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specially developed for such measurements Soil Gas Probe through the air pump and filter system. After the Probe was inserted, the ground has been tamped down around the probe, to prevent air from moving ...
2002-10-08
Real-time monitoring of moisture levels in wound dressings in vitro: An experimental study
British Library Electronic Table of Contents (United Kingdom)
Retaining an appropriate level of moisture at the interface between a healing wound and an applied dressing is considered to be critical for effective wound healing. Failure to control exudate at this interface can result in maceration or drying out of the wound surface. The ability to control moisture balance at the wound interface is therefore a key aspect of wound dressing performance. To date it has not been possible to monitor in any effective manner the distribution of moisture within dressings or how this varies with time.A new measurement system is presented based on sensors placed at the wound/dressing interface which are capable of monitoring moisture levels in real time. The system comprises a model wound bed and sensor array complete with fluid injection path to mimic exudate f...
2007-01-01
Spectral characteristics of lignite open cast mining systems: a preliminary status
Energy Technology Data Exchange (ETDEWEB)
The application of a Compact Airborne Spectrographic Imager to assessment and monitoring of lakes in a lignite open cast mining area in central Germany is described. The imager was used in combination with additional ground experiments, such as field spectroscopy and water sampling. The spectral characteristics of an instrument under development for monitoring geochemical and hydrological processes are presented. Summary form only.
1999-07-01
Energy Technology Data Exchange (ETDEWEB)
The steam generator low water level trip setpoint of KORI NPP units 3 and 4(KNU 3 and 4), three-loop Westinghouse pressurized water reactor, is higher than that of OPR1000. In addition, steam generator downcomer water level in KNU 3 and 4 could fluctuate easily during a transient because of smaller downcomer water inventory, compared to the total water inventory in the steam generator. Due to these reasons, there is a higher possibility of unnecessary reactor trips caused by the steam generator low-low water level in KNU 3 and 4. Its operating history shows that most of reactor trips were caused by steam generator low-low level reactor trip signal. Such reactor trips, especially unnecessary ones, result in time and economic losses. In this paper, a feasibility study was performed ...
2008-10-15
International Nuclear Information System (INIS)
The steam generator low water level trip setpoint of KORI NPP units 3 and 4(KNU 3 and 4), three-loop Westinghouse pressurized water reactor, is higher than that of OPR1000. In addition, steam generator downcomer water level in KNU 3 and 4 could fluctuate easily during a transient because of smaller downcomer water inventory, compared to the total water inventory in the steam generator. Due to these reasons, there is a higher possibility of unnecessary reactor trips caused by the steam generator low-low water level in KNU 3 and 4. Its operating history shows that most of reactor trips were caused by steam generator low-low level reactor trip signal. Such reactor trips, especially unnecessary ones, result in time and economic losses. In this paper, a feasibility study was performed ...
2008-10-01
Device for controlling water supply to nuclear reactor
International Nuclear Information System (INIS)
Object: To smoothly control automatic water supply for realizing stable operation of a nuclear reactor by providing a flow rate limiting signal selection circuit and a preferential circuit in a water supply control device for a nuclear reactor wherein the speed of a recirculation pump may be changed in two-steps. Structure: Opening angle signals for a water supply regulating valve are controlled by a nuclear reactor water level signal, a vapor flow rate signal and a supplied water flow rate signal through an adder and an adjuster in response to a predetermined water level setting signal. When the water in the reactor is maintained at a predetermined level, a selection circuit receives a water pump condition signal for selecting one of the signals from a ...
Use of man-made impoundment in mitigating acid mine drainage in the North Branch Potomac River
International Nuclear Information System (INIS)
The US Department of the Army, Baltimore District Corps of Engineers, oversees a long-term monitoring study to assess and evaluate effects of the Jennings-Randolph reservoir on biota in the North Branch Potomac River. The reservoir was intended, in part, to mitigate effects of acid mine drainage originating in upstream and headwater area. The present study assessed recovery of benthos and fish in this system, six years after completion of the reservoir. Higher pH and lower iron and sulfate concentrations were observed upstream of the reservoir compared to preimpoundment conditions, suggesting better overall water quality in the upper North Branch. Water quality improved slightly directly downstream of the reservoir. However, the reservoir itself was poorly colonized by macrophytes and benthic organisms, and plankton composition suggested either metal toxicity and/or nutrient limitation. One large tributary to the North ...
Early forecast of radiation-hazardous solar cosmic ray fluxes on the neutron monitors data
The system of the early forecast of radiation hazardous fluxes of solar cosmic rays in space on the basis of the real time neutron monitors data obtained by the NMDB (Neutron Monitor Data Base) network is created. The forecast system is based on a short cut technique of definition of a spectrum of solar protons from the data of the limited number of neutron monitor stations and with a simplified procedure of accounts. It is shown that the results of computations of solar proton spectra with the short-cut technique little differ from spectra obtained with a complete technique at energies less than 5 GeV. Thus the good agreement between derived from the neutron monitor data intensities of solar protons in an energy range of hundreds MeV with the data of direct measurements of solar protons at GOES-11 spacecraft is observed. The maximum of increase on neutron monitors outstrips on ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
Multitemporal TM images are used to collect information about the extension and variation of water influx subsidence in coal district in order to provide a reference for the harnessing and utilization of water influx subsidence. The multitemporal TM images are used as a blended data group for the analysis of the principal components to reflect the expanding water influx subsidence in the past years. Because of the differences in the environment and imaging condition, 'unitary' order is used to enhance the 'coherence' and 'comparability' of the original TM images. 5 refs., 4 figs., 2 tabs.
2002-08-01
Energy Technology Data Exchange (ETDEWEB)
MPFDs are a new class of detectors that utilize properties from existing radiation detector designs. A majority of these characteristics come from fission chamber designs. These include radiation hardness, gamma-ray background insensitivity, and large signal output.
2006-06-12
Health hazards to children due to the Chernobyl accident?
International Nuclear Information System (INIS)
The article tries to assess the radiation effects as objectively as possible. In conclusion, some steps that should be taken in future are listed, as e.g.: continuous monitoring of the radioactivity levels in air and soil, and recording of data for complete information. Further, investigation and assessment of radiation exposure of children, especially in regions most heavily affected; radioactivity monitoring of the food and milk given to children, and scientific research into the problem by pediatrists, and determination of maximum acceptable radiation doses. (orig./HSCH).
Toward a Unified Timestamp with explicit precision
UK PubMed Central (United Kingdom)
Demographic and health surveillance (DS) systems monitor and document individual and group-level processes in well-defined populations over long periods of time. The resulting data are complex...Full Text Available
2005-03-30
UK PubMed Central (United Kingdom)
BackgroundCharacterizing infectious disease burden in Africa is important for prioritizing and targeting limited resources for curative and preventive services and monitoring the...Full Text Available
UK PubMed Central (United Kingdom)
Human epidermal growth factor receptor 2 (HER2) is one of the most important prognostic and predictive factors for breast cancer patients. Recently, serum HER2...Full Text Available
Effect of structured postgraduate medical education on the care of patients with diabetes.
UK PubMed Central (United Kingdom)
BACKGROUND. Diabetes can be effectively treated and monitored in general practice. Postgraduate medical education at a local level is required to support this strategic shift of medical care from hospital...Full Text Available
1995-03-01
Development of barcode system for internal dose monitoring
International Nuclear Information System (INIS)
In Tarapur Atomic Power Station unit-3 and 4, which is 540 MWe pressurized heavy water reactor, tritium is produced in primary heat transport system and moderator system. Tritium is a major contributor to the internal dose. Internal dose contributes about 30% of the collective dose. Internal dose monitoring and its control are important to control the collective dose. Estimation of internal dose is done by analysis of bioassay samples of radiation workers. In a month, about 7000 bioassay samples are analysed for the internal dose assessment during normal operation, and about 12000 during the biennial shut down of the reactor. To enhance the sample preparation and counting performance, minimize the entry errors and reduce the processing time, barcode based label generation system was developed for the internal dose monitoring. This paper discusses about the use of barcode system in the internal dose ...
2008-11-19
Water consumption of a six-year-old river red gum plantation in the Southern Zagros Mountains, Iran
British Library Electronic Table of Contents (United Kingdom)
Water is the most important limiting factor in the development of arid environments; therefore, optimization of water use is a necessity in desert reclamation projects. Evapotranspiration of a 6-year-old river red gum (Eucalyptus camaldulensis Dehnh.) plantation, located in a sedimentation basin of an artificial recharge of the Gareh Bygone Plain groundwater system in Iran?s southern Zagros Mountains, was studied during a 7-month period. A neutron moisture probe was used to monitor soil water changes in the root zone. Soil water depletion following rapid drainage for blocks receiving relatively high, medium and low volumes of floodwater were 809.6, 312.4, and 203.1 mm, respectively, for a 150-day period. Soil water potential during most of the study period was below ?1.5 MPa. This study pr...
2007-01-01
British Library Electronic Table of Contents (United Kingdom)
Summary Objective Community-based information on the delivery and use of health interventions is important to monitor the effectiveness of the Roll Back Malaria programme. However, community surveys to determine coverage for insecticide-treated bed nets are time-consuming and costly. We wanted to assess whether schoolchildren's reports of household ownership of a bed net and coverage among high-risk groups monitored by schoolteachers through a questionnaire could be used as a proxy of household ownership of bed net and coverage at community level, for routine monitoring of malaria control programmes. Method 3602 schoolchildren in 39 randomly selected schools and 2798 heads of households in 39 villages were interviewed about their use of either insecticide-treated or untreated bed nets. Res...
2007-01-01
TLA monitoring of an anodic protection system
Energy Technology Data Exchange (ETDEWEB)
Corrosion is a materials degradation process that engineering personnel in the pulp and paper industry have had to accept as unavoidable to some degree, due to aggressive processing conditions prevalent in paper mills. The increasing incidence of corrosion-related failures in plant and equipment has resulted in the introduction of new techniques to monitor corrosion rates, since many of the more traditional methods do not provide data that is either recent or accurate enough. Thin layer activation (TLA) is a new corrosion monitoring technique which has recently been employed to measure corrosion trends inside a continuous pulp digester. With TLA a surface is irradiated by a particle beam from a nuclear accelerator, causing it to be labelled with an accurate depth profile and low level radioactivity. By monitoring this activity, it is possible to calculate how much of the surface has been removed by ...
1992-03-01
TLA monitoring of an anodic protection system
International Nuclear Information System (INIS)
Corrosion is a materials degradation process that engineering personnel in the pulp and paper industry have had to accept as unavoidable to some degree, due to aggressive processing conditions prevalent in paper mills. The increasing incidence of corrosion-related failures in plant and equipment has resulted in the introduction of new techniques to monitor corrosion rates, since many of the more traditional methods do not provide data that is either recent or accurate enough. Thin layer activation (TLA) is a new corrosion monitoring technique which has recently been employed to measure corrosion trends inside a continuous pulp digester. With TLA a surface is irradiated by a particle beam from a nuclear accelerator, causing it to be labelled with an accurate depth profile and low level radioactivity. By monitoring this activity, it is possible to calculate how much of the surface has been removed by ...
A radiation monitoring system for nuclear fusion devices
International Nuclear Information System (INIS)
Fusion device produces high-level neutrons and #gamma#-rays, which would hazard the safety of the public and workers if the doses would be higher than the regulatory limits because of leakage from the bio-shielding and skyshine. It is essential to monitor the radiation doses in the workshop and the enumerative around fusion devices. A radiation monitoring system (RMS) for full (near and far) areas around a nuclear fusion device has been designed and developed, which can achieve the monitoring and controlling of radiation doses in the workshop area by using the Controller Area Network (CAN), in the institution area by using the Bluetooth Ad hoc network based on a new tree topology formation and routing protocol and in a long range environment by using the General Packet Radio Service (GPRS) network. (authors)
2005-12-01
Performance Assessment Monitoring Plan for the Hanford Site Low-Level Burial Grounds
Energy Technology Data Exchange (ETDEWEB)
The U.S. Department of Energy Order 435.1, Radioactive Waste Management, requires a disposal authorization statement authorizing operation (or continued operation) for low-level waste disposal facilities. In fulfillment of these requirements, a disposal authorization statement was issued on October 25, 1999, authorizing the Hanford Site to transfer, receive, possess, and dispose of low-level radioactive waste at the 200 East Area burial grounds and the 200 West Area burial grounds. One of the conditions is that monitoring plans for the 200 East Area and 200 West Area low-level burial grounds be written and approved by the Richland Operations Office. As a result of a record of decision for the Hanford Site Solid Waste Program and acceptance of the Hanford Site Solid Waste Environmental Impact Statement, the use of the low-level burial ground (LLBG) as a disposal facility for ...
2006-03-30
Energy Technology Data Exchange (ETDEWEB)
This report discusses environmental surveillance activities conducted on the Nevada Test Site during the first calendar quarter of 1996. Surveillance activities included collection and analysis of air, noble gas, tritiated water vapor, and other water samples. Samples were analyzed for both radiological and non-radiological effluents.
1996-11-01
The Philadelphia Marriott: A convention center flagship hotel
Energy Technology Data Exchange (ETDEWEB)
This article describes the state-of-the-art HVAC system at the Philadelphia Marriott Hotel. Thermal comfort and indoor air quality are emphasized. The system uses a hybrid gas absorption/electric centrifugal chilled water plant, variable flow pumping, water-side economizers to provide free cooling, central air handling units with air-side economizers and flow monitoring equipment.
1997-01-01
Pollution control instrumentation for oil and effluents
Energy Technology Data Exchange (ETDEWEB)
This book provides discusses recent developments in oil pollution control instrumentation. Some of the topics covered are as follows: 1. Technical requirements of the IMCO International Performance and Test Specification A393x concerning oil content meters; and 2. Oil in water detection; and 3. Methods for the disposal of recovered oil and oily sludge; and 4. Oil content monitoring at ballast water treatment facilities and offshore production platforms.
1986-01-01
Fouling Study of Silicon Oxide Pores Exposed to Tap Water
Energy Technology Data Exchange (ETDEWEB)
We report on the fouling of Focused Ion Beam (FIB)-fabricated silicon oxide nanopores after exposure to tap water for two weeks. Pore clogging was monitored by Scanning Electron Microscopy (SEM) on both bare silicon oxide and chemically functionalized nanopores. While fouling occurred on hydrophilic silicon oxide pore walls, the hydrophobic nature of alkane chains prevented clogging on the chemically functionalized pore walls. These results have implications for nanopore sensing platform design.
2007-07-12
International Nuclear Information System (INIS)
Using the Laser-Fluorescence technique, an investigation was made, adopting the standard mix method, on trace uranium concentrations in hot spring water and geothermal water from Lishan region, and in tap water from some major cities in Shanxi province. Totally 40 samples from 27 sites were investigated. Measurement showed that the tap water contains around 10"-"6 g/L of uranium, whose concentrations in both hot spring water and geothermal water are 10"-"5 g/L. Most of samples are at normal radioactive background level, some higher contents were determined in a few samples
2002-03-01
Behavior of ice covers subjected to large daily flow and level fluctuations
Energy Technology Data Exchange (ETDEWEB)
The stability of a solid ice cover subjected to rapidly varying water levels and discharge was investigated. The support from the bank limits the stress in the ice cover and consequently bank contact must be maintained to ensure ice cover stability. An analysis was required of the stability of ice hinges, a flexible connection between a solid ice cover and the riverbank. Phase II and phase III of the research involved a field study of the Peace River, investigating the evolution of ice hinges with water level variation, from initial ice cover cracking parallel to the banks, to a fully developed hinge. A test program of midwinter discharge variations was undertaken to gather specific data and measurements of ice hinge link length, ice thickness, hinge joint behavior, riverbank geometry, and response of ice hinging to water level variation. This volume of ...
1984-11-01
International Nuclear Information System (INIS)
This study evaluates the degree to which surface impoundments at licensed facilities comply with significant changes in NRC requirements initiated by enactment of EPA's final environmental standards for uranium recovery facilities (40 CFR Part 192). Impoundment liner requirements, ground-water protection standards, ground-water monitoring and corrective action programs, and site closure standards are the most significant regulatory modifications. The compliance status of 30 conventional mills and 31 in-situ mines is determined from a review of Nuclear Regulatory Commission and agreement state docket files through November, 1983. Results of this review show that a majority of conventional uranium mill tailings management systems are deficient with respect to liner requirements for new impoundments or proposed expansions to existing impoundments, as well as with respect to some aspects of ground-water ...
Energy Technology Data Exchange (ETDEWEB)
The pilot area of the Vyngapour oil field allotted for MIOR tests contains three injection and three producing wells. These wells were treated in summer 1993 and 1994. Before, during, and after MIOR treatments on the pilot area the chemical compounds of injected and formation waters were studied, as well as the amount and species of microorganisms entering the stratum with the injected water and indigenous bacteria presented in bottomhole zones of the wells. The results of monitoring showed that the bottomhole zone of the injection well already had biocenosis of heterotrophic, hydrocarbon-oxidizing, methanogenic, and sulfate-reducing bacteria, which were besides permanently introduced into the reservoir during the usual waterflooding. The nutritious composition activated vital functions of all bacterial species presented in the bottomhole zone of the injection well. The formation waters from producing ...
1995-12-31
Energy Technology Data Exchange (ETDEWEB)
Water-resources data for the 1993 water year for Texas are presented in four volumes, and consist of records of stage, discharge, and water quality of streams and canals; and stage, contents, and water quality of lakes and reservoirs; and water levels and water quality of ground-water wells. Volume 3 contains records for water discharge at 134 gaging stations; stage only at 1 gaging stations; stage and contents at 13 lakes and reservoirs; water quality at 81 gaging stations; and data for 30 partial-record and 4 flood-hydrograph partial-record stations. Also included are lists of discontinued surface-water discharge or stage-only stations and discontinued surface-water-quality stations; crest-stage and flood-hydrograph partial-record ...
1994-03-01
Distributed radiation protection console system
International Nuclear Information System (INIS)
Radiation exposure control is one of the most important aspects in any nuclear facility . It encompasses continuous monitoring of the various areas of the facility to detect any increase in the radiation level and/or the air activity level beyond preset limits and alarm the O and M personnel working in these areas. Detection and measurement of radiation level and the air activity level is carried out by a number of monitors installed in the areas. These monitors include Area Gamma Monitors, Continuous Air Monitors, Pu-In-Air Monitors, Criticality Monitors etc. Traditionally, these measurements are displayed and recorded on a Central Radiation Protection Console(CRPC), which is located in the central control room of the facility. This methodology suffers from ...
2004-02-01
UK PubMed Central (United Kingdom)
A previous report of high levels of members of the domain Archaea in Antarctic coastal waters prompted us to investigate the ecology of Antarctic planktonic prokaryotes. rRNA hybridization...Full Text Available
1998-07-01
Reduced Accumulation of ABA during Water Stress in a Molybdenum Cofactor Mutant of Barley 1
UK PubMed Central (United Kingdom)
A barley (Hordeum vulgare L.) mutant (Az34) has been identified with low basal levels of abscisic acid (ABA) and with reduced capacity for producing ABA in response to water stress....Full Text Available
1989-06-01
Childhood cancer mortality and radon concentration in drinking water in North Carolina.
UK PubMed Central (United Kingdom)
We explored the association between groundwater radon levels and childhood cancer mortality in North Carolina. Using data from two state-wide surveys of public drinking water supplies, counties were...Full Text Available
1991-04-01
Transfer of 137Cs and 60Co in a waste retention pond with emphasis on aquatic insects
International Nuclear Information System (INIS)
The objectives of this research were (1) to analyze the transfers of 137Cs and 60Co in a retention pond, with emphasis on aquatic insects and (2) to determine if detectable concentrations of these radionuclides are exported by emerging aquatic insects. We analyzed the radionuclide concentrations in the following components: water solution, bottom sediments, suspended particulate matter, plankton, floating mats of filamentous algae, benthic macroinvertebrates, and emerging aquatic insects. Samples were collected quarterly from June 1981 to April 1982. The lowest concentrations (in picocuries per milliliter) occurred in solution (range: 1.4 X 10(2) to 3.2 X 10(2) for 137Cs and 8.1 X 10(-1) to 2.2 X 10(0) for 60Co). The highest concentrations (in picocuries per gram dry weight) occurred in the sediments (range: 1.5 X 10(4) to 1.1 X 10(8) for 137Cs and 1.0 X 10(2) to 4.3 X 10(6) for 60Co). The primary producers and aquatic insect consumers had concentrations of both ...
Energy Technology Data Exchange (ETDEWEB)
Vermicomposts as a biofertilizer can be a great option for pond manuring as they never cause any long term harm to the soil like chemical fertilizer. In this study vegetable and horticulture waste was used as an important media for vermiculture. Three separate cemented tanks (6 m{sup 3} each) were used in the system as control tank, vermicompost fertilized tank and inorganic fertilizer manured tank. Monoculture of fish was carried out with cat fish, Clarias batrachus. The produced earthworms were used as fish feed. Regular monitoring of water parameter was conducted in three different ponds. Specifically, the algal biomass variation was quite helpful in analysing the behavior of the ponds. NPK value of soil samples was analyzed intermittently to know the eutrophication level. Despite the hot summer temperature in northern part of India, which is not ideal for fish growth, we have recorded an encouraging growth performance ...
2004-05-01
International Nuclear Information System (INIS)
In this paper, we calculated the radioactive concentration distribution of radioactive waste water, the temperature distribution of drained cooling water and the effect of implement from the Daya Bay Nuclear Power Plant on nearby waters range, discussed and analysed some problems of computational results and computation with Alternating Direction Implicit Method (ADI). The contents of the article included: the establishment of two-dimension tidal current equation, radioactive waste water pollutant dispersion equation and cooling water heat convection diffusion equation, the numerical difference calculation model of tidal current field, concentration field as well as temperature field, effect impingement with ADI method, numerical calculation results. The result of research showed that: when the Daya Bay Nuclear Power Plant is on normal operation and after the low ...
Environmental levels of tritium, 2
International Nuclear Information System (INIS)
In an attempt to obtain basic data for evaluation of exposure doses in Niigata Prefecture, the concentrations of tritium in atmospheric water, precipitation, river water, and tap water were measured. Samples of atmospheric water, river water, and tap water were collected once for 2 weeks; and precipitation collected for one week was used as sample. The concentration of atmospheric tritium depended on the concentration of tritium in moisture and the content of water in atmosphere. Tritium levels were high in May, November and March, and low in September. Regarding tritium concentrations, there was a good correlation between atmospheric water and precipitation. Tritium concentrations in both of them varied from sample to sample. The concentrations of tritium in river and tap water ...
Performance of SPNDs used in control and safety systems
International Nuclear Information System (INIS)
Large sized reactor such as 540 MWe Pressurised Heavy Water Reactor (PHWR) requires continuous in core monitoring of local flux in order to provide effective control and protection. About 198 self powered neutron detectors (SPNDs) of the straight individually replaceable type are distributed in the reactor core. For purposes of reactor regulation, 42 prompt responding cobalt SPNDs called zone control detectors (ZCDs) are housed in vertical flux units (VFUs) and these are uniformly distributed in 14 power zones. The in core detectors used for spatial control by ZCCs do not accurately represent average zone power as they sense the flux over a small volume. Flux mapping system (FMS) comprising of 102 vanadium SPNDs in 26 VFUs, provide accurate measure of neutron flux, even though they have slow response to change in neutron flux levels. For reactor protection system-1 (RPS-1), 36 cobalt SPNDs are placed in VFUs and become part ...
2006-11-13
Radiostrontium in milk and tap water. Appendix D
International Nuclear Information System (INIS)
Results of monitoring milk and tap water in New York City are presented. The New York City sample is a monthly composite of pasteurized milk purchased daily at retail stores. The monthly "9"0Sr to calcium ratios for New York City since the inception of the sampling program in 1954 are presented. Samples of New York City tap water are taken daily, so that by the end of the month, approximately 100 liters have been collected. The available cesium-137 data expressed as the "1"3"7Cs to "9"0Sr ratio are also given.
1980-01-01
Environmental Research Database
ObjectivesObjectives Not AvailableDescriptionTo determine the effects of water penetration on the burst strength of filament wound composite pipes which have been damaged by impact and then subjected to long term pressurisation with sea water. ~%~ To monitor and characterise the damage and effects of sea water penetration using ultrasonic NDT. To determine the burst strength of bonded composite pipe joints with and without defects and to see whether the defects can be detected using ultrasonic NDT. [continued...
1996-01-31
Energy Technology Data Exchange (ETDEWEB)
This report summarizes the project implementation and monitoring of all habitat activities that occurred over Fiscal Year 2002 (FY 02). Some of the objectives in the corresponding statement of work for this contract were not completed within FY 02. A description of the progress during FY 02 and reasoning for deviation from the original tasks and timeline are given. OBJECTIVE 1--Provide coordination of all activities, administrative oversight and assist in project implementation and monitoring activities. Administration oversight and coordination of the habitat statement of work, budget, subcontracts and personnel was provided. OBJECTIVE 2--Develop, coordinate, and implement the Hood River Fish Habitat Protection, Restoration, and Monitoring Plan. The Hood River Fish Habitat Protection, Restoration, and Monitoring Plan was completed in 2000 (Coccoli et al., 2000). This document is utilized for many ...
2003-11-01
Thermoelectrically cooled water trap
Energy Technology Data Exchange (ETDEWEB)
A water trap system based on a thermoelectric cooling device is employed to remove a major fraction of the water from air samples, prior to analysis of these samples for chemical composition, by a variety of analytical techniques where water vapor interferes with the measurement process. These analytical techniques include infrared spectroscopy, mass spectrometry, ion mobility spectrometry and gas chromatography. The thermoelectric system for trapping water present in air samples can substantially improve detection sensitivity in these analytical techniques when it is necessary to measure trace analytes with concentrations in the ppm (parts per million) or ppb (parts per billion) partial pressure range. The thermoelectric trap design is compact and amenable to use in a portable gas monitoring instrumentation.
2006-02-21
British Library Electronic Table of Contents (United Kingdom)
Human activities in the karst Ozark Plateaus can impact water quality of springs where surface water is rapidly transferred to subsurface conduits. Bennett Spring, in southern Missouri, is the fourth largest spring in the state and supports local tourism activities. Questions regarding poorly functioning on-site wastewater systems (OWS) have raised concerns over the long-term water quality of the spring. This study reports the results of a surface water quality monitoring program in the recharge area where monthly samples were collected at base flow to identify potential pollution sources to the spring. Base flow hydrology of the recharge area was highly variable over the study period, which was drier than normal, causing an incomplete sampling record due to no flow conditions at some site...
2011-01-01
Environmental Research Database
DescriptionFarm-level estimates of the financial impact of regulation are important indicators of the effect that a regulation have. Such estimates should be included in RIA, particularly within the Small Firms Impact Test. This farm-level analysis can be used in the RIA to inform judgements of the affordability of the regulation proposal. It will help to identify which farm types are likely to be financially had-hit from the regulation. Farm-level cost estimates for each regulation are also required t [continued...
2007-01-23
Device for controlling feedwater at low power of nuclear power plants
International Nuclear Information System (INIS)
Purpose: To provide a feedwater control device capable of minimizing the adverse response of steam drum level at low power. Consitution: In order to perform feedwater control at low power by the substantial control of three factors, that is, main steam flow rate, feedwater flow rate and steam drum level, the main steam flow rate is determined from the reactor output and feedwater rate is determined from the changes in the feedwater temperature due to the mixing of waters in the reactor clean up system and feedwater. If a difference is resulted between these flow rates, a starting feedwater regulator is controlled instantly to eliminate the difference. The water level in the steam drum is used for amending the difference from the final set value of the drum water level, by which the adverse response of the steam drum ...
International Nuclear Information System (INIS)
Immunoassays are versatile analytical techniques that had a leading role in various clinical applications, during the last four decades. The studies carried out by Rosalyn Yalow, Solomon Berson and Roger Ekins in the 1960s gave a breakthrough in the development of this novel analytical method. Sensitivity up to femtomolar concentrations, high specificity and universal application to different classes of molecular species made immunoassay a very useful tool in analytical investigation. The expertise acquired by immunochemists in producing antibodies against any antigen and the ability of radiochemists in labeling the antigens with "1"2"5I without affecting the active site are the two main factors responsible for the above development. There are concerns about the safety and health of humans due to the high-level contamination of environment by pesticides, industrial compounds and metals, anabolic steroids in milk and meat products, and presence of mycotoxins in food ...
2004-12-06
Terra Nova Environmental effects monitoring program
Energy Technology Data Exchange (ETDEWEB)
Elements of the environmental effects monitoring program in the Terra Nova oil field, about 350 km east-southeast of St. John's, Newfoundland, are described. This oilfield is being developed using a floating production storage and offloading (FPSO) facility. A total of 24 wells are expected to be drilled through seven subsea templates located in four glory holes to protect them from icebergs. Subsea installations will be linked to the FPSO by trenched flowlines connected to flexible risers. The FPSO will offload to shuttle tankers. First oil is expected in 2001. The environmental effects monitoring program will be conducted annually for the first two years beginning in 2000. Subsequent scheduling will be determined after a review of monitoring data collected during the first three years. Input to the design of the monitoring program was provided by all stakeholders, i. e. owners, local public, ...
2000-07-01
Energy Technology Data Exchange (ETDEWEB)
Counter-current regeneration of 2-stage sodium zeolite softeners has been employed in reducing hardness leakage level of steamflooding water to less than 1 ppm when raw water contains as much as 5,000 ppm of the total dissolved solids. Hardness leakage is caused by sodium displacement of calcium and magnesium from the bottom of the exchanger bed. This study presents nomographs providing for rapid calculations to be made, for which a convenient operational mode does not already exist. The nomographs relate the hardness leakage as a function of salt quality and influent water quality and present solutions for predicting the leakage level, salt quality requirement or the treatability of raw water required for steamflooding projects.
1982-08-01
Trace elements were extracted from a coal-fired power plant electrostatic precipitator ash with nitric acid, hydrochloric acid, citric acid, redistilled water, and ammonium hydroxide as extractants. Effluent waters at this plant were sampled to assess the elevation of trace element concentrations compared with intake waters. The results showed a positive correlation between those elements most extractable by water (B, F, Mo, and Se) or acid (As, B, Cd, F, Mo, and Se) and those elements most elevated in effluent waters (As, B, F, Mo, and Se).
1977-10-01
International Nuclear Information System (INIS)
This paper introduces the inter-comparison results of some environmental radioactivity monitoring items for Daya Bay nuclear power plant. The inter-comparison was organized by China Institute for Radiation Protection and five laboratories participated in it. The compared items included total #beta# in kelp and sediment, "3H in water, "9"0Sr in soil, artificial nuclides "1"1"0"mAg, "2"4"1Am, "1"0"9Cd, "5"7Co in kelp and sediment. Inter-comparison results are analyzed as well
2003-01-01
Radiation hazard control report
Energy Technology Data Exchange (ETDEWEB)
The radiation control carried out in Atomic Energy Research Institute, Kinki University, for the reactor installation and the tracer/accelerator facilities from April, 1981, to March, 1982, is described. The reactor was operated for total 1057.1 hours at the maximum heat output of 1 W. The persons subject to radiation protection as of April, 1981, were 126 persons in all, including 23 in radiation work and 11 in X-ray work, etc. The contents of this report are as follows: personnel monitoring (health examination, the control of individual exposure dose); laboratory monitoring (the measurement of area dose rate, radioactive concentration in air and water, and surface contamination density); field monitoring (environmental ..gamma..-ray dose rate, radioactive concentration in environmental samples); the use of unsealed radioisotopes, etc.
1982-12-01
Barriers for radon in uranium mines. Report of investigations 1977
International Nuclear Information System (INIS)
Water-based epoxy sealants were examined during a 2-year period to determine their effectiveness as barriers to radon release in uranium mines. Radon emanation rates from uranium ore samples were monitored for extended periods in the laboratory before and after sealant application. Reduction of radon flux due to the coating of lab samples was approximately 80 percent. Test chambers in a dormant uranium mine were monitored to determine both short and long-term barrier effectiveness. These field studies of the sealants indicated reductions greater than 50 percent relatively soon after application and nearly 75 percent more than 1 year later. An unexpected complication to early monitoring in the form of a large radon emanation increase, believed due to added moisture, is discussed.
From tankers to tissues : tracking the degradation and fate of oil discharges in Port Valdez, Alaska
Energy Technology Data Exchange (ETDEWEB)
An average of 9 million gallons per day of oil-contaminated ballast water off loaded from tankers are treated at the Alyeska Pipeline Service Company Ballast Water Treatment Facility at the terminus of the Trans-Alaska Pipeline in Port Valdez, Alaska. This paper focuses on the results of 2 Prince William Sound Regional Citizens' Advisory Council monitoring programs which detail changes in the chemical composition of treated ballast water as it moves from tankers through the facility and subsequently traces the effluent hydrocarbons into the receiving environment of Port Valdez. The treatment facility involves gravity separation tanks, dissolved air flotation cells and biological treatment tanks. Effluent containing traces of volatile aromatics, including benzene, toluene, ethylbenzene and xylenes, low levels of oil, saturated hydrocarbons and polycyclic aromatic ...
2005-07-01
Tissue equivalent proportional counter real time neutron monitor
International Nuclear Information System (INIS)
The Tissue Equivalent Proportional Counter (TEPC) was developed to monitor low level neutron exposure rates at working stations in a nuclear fuel fabrication facility. It has proven capable of accurately measuring neutron dose rates at levels from 0.1 to 0.2 mrem/hr. It also calculates the Quality Factor which is of importance in locations where the neutron to gamma ratio may vary significantly and irregularily. The system described is computerized to monitor 100 work locations simulationeously and can be expanded to monitor 384 locations. Neutron dose is accumulated on a real time basis and after the proton drop point is established, dose rate can be read out at any time for the dose accumulated over a specified period of time. The current development program which provides reduced system maintenance, lower detection limits, and improved accuracy is discussed along with examples of ...
1978-10-25
Energy Technology Data Exchange (ETDEWEB)
Until now, monitoring of power transformers focussed mainly large generator and network transformers. Siemens goes a step ahead and provides a system especially developed and designed for small and medium power transformers, e.g. for the 100 kV level. This low cost version could be achieved by restriction to really necessary measuring quantities. This allows to realize also for small and medium power transformers an online monitoring including an estimation of aging and as an option an early warning to avoid unexpected failures. (orig.) [German] Die Ueberwachung (Monitoring) von Leistungstransformatoren war bisher vor allem fuer Maschinentransformatoren und grosse Netzkuppeltransformatoren in der Diskussion. Siemens geht einen Schritt weiter und stellt nun auch ein System bereit, das speziell fuer kleine und mittlere Leistungstransformatoren, z.B. der 110-kV-Spannungsebene, konzipiert ist. Diese ...
1999-09-20
Hanford Site Environmental data for Calendar Year 1990. Surface and Columbia River
Energy Technology Data Exchange (ETDEWEB)
Environmental monitoring at the Hanford Site, located in southeastern Washington State, is conducted by Battelle Memorial Institute, Pacific Northwest Division, as part of its contract to operate the Pacific Northwest Laboratory (PNL) for the US Department of Energy. The data collected provide a historical record of radionuclide and radiation levels attributable to natural causes, worldwide fallout, and Hanford operations. Data are also collected to monitor several chemicals. Pacific Northwest Laboratory publishes an annual environmental report for the Hanford Site each calendar year. The Hanford Site Environmental Report for Calendar Year 1990 is a summary of offsite and onsite environmental monitoring data collected during 1990 by PNL`s Environmental Monitoring Program. The data summaries included in the annual report were created from individual surface and river ...
1992-01-01
Hanford Site Environmental data for Calendar Year 1990
Energy Technology Data Exchange (ETDEWEB)
Environmental monitoring at the Hanford Site, located in southeastern Washington State, is conducted by Battelle Memorial Institute, Pacific Northwest Division, as part of its contract to operate the Pacific Northwest Laboratory (PNL) for the US Department of Energy. The data collected provide a historical record of radionuclide and radiation levels attributable to natural causes, worldwide fallout, and Hanford operations. Data are also collected to monitor several chemicals. Pacific Northwest Laboratory publishes an annual environmental report for the Hanford Site each calendar year. The Hanford Site Environmental Report for Calendar Year 1990 is a summary of offsite and onsite environmental monitoring data collected during 1990 by PNL's Environmental Monitoring Program. The data summaries included in the annual report were created from individual surface and river ...
1992-01-01
Energy Technology Data Exchange (ETDEWEB)
Effect of water injection/draining on elastic waves penetrating through cracks is examined by measuring elastic waves before, during, and after the injection/draining of water into/from cracks in presence in granite. Two blocks of rock, with their crack-containing surfaces in contact with each other, are placed in a vessel, and water injection/draining is done through a hole on a vessel bottom side so that water will penetrate into the cracks. When the blocks are dry, there is almost no contact between the cracks, and so no crack penetrating waves are observed. Crack penetrating waves are produced when water is injected, and the position of the receiver sensing the penetrating waves changes as the water level rises. When the water level is lowered from the high water ...
1997-05-27
Ventilation by the windows in classrooms: a case study
Energy Technology Data Exchange (ETDEWEB)
Four classrooms of two secondary schools located around Lyon in France have been monitored. The objectives are to analyse the quality of the indoor air and the thermal comfort and also the behaviour of the occupants towards opening of the windows. This paper briefly describes the context and the nature of the monitoring campaign, and presents the results of the measurements with direct interpretation of the ventilation needs. Results from this study show that allowable CO{sub 2} levels are overpassed several times in a school day. The presence of a mechanical ventilation system leads to lower peaks but the fresh airflow is too small to prevent an indoor confining, that is also revealed by the aerobiological analysis. (author)
1994-12-31
Energy Technology Data Exchange (ETDEWEB)
The measurement of air pollutants is no more sufficient. It is necessary to assess the risk induced by air pollution, and then to put in place actions to reduce it. The air quality monitoring takes into account different pollutants: nitrogen oxides, carbon monoxide, particulates for the traffic; sulfur dioxide and particulates for use of fuel or coal or chemical transformations in air; ozone and nitrogen dioxide from hydrocarbon and nitrogen oxides emissions; the use of simulation methods allow to calculate the concentrations levels for these pollutants taken as indicators. (N.C.)
2000-07-01
Neutron monitoring on cold fusion experiments
International Nuclear Information System (INIS)
A helium-3 proportional detector was equipped with the experiment of Liaw-type electrolytic cell contained eutectic LiCl-KCl molten salt saturated by LiD electrolytic to collect the informations of the rate and the energy distribution of possible neutron produced during the electrolysis processes. For long time monitoring, the significant reproducible neutron bursts appeared at several runs of cells during electrolytic processing. The neutron counting rate increased about a factor of two above the level of the background measurement. The pulse height signals were verified of neutron energy ranging from thermal up to 350 keV. (author).
1992-10-01
FFTF core and primary sodium circuit instrumentation
International Nuclear Information System (INIS)
Plans, engineering parameters, and some test results for several FFTF core and primary sodium circuit instrument systems are presented. The systems discussed include temperature, flow, pressure, leak detectors, level sensors, fuel failure monitoring, sodium impurity analysis and cover gas monitors. Since many of these instruments are similar to those used in other fast reactors around the world, only a brief description is presented for these systems. Results of recent demonstration tests of the FFTF Under-Sodium Viewing and Ranging system are also presented. (U.K.).
Beam position monitor readout and control in the SLC linac
Energy Technology Data Exchange (ETDEWEB)
A beam position monitoring system has been implemented in the first third of the SLC linac which provides a complete scan of the trajectory on a single beam pulse. The data is collected from the local micro-computers and viewed with an updating display at a console or passed on to application programs. The system must operate with interlaced beams so the scans are also interlaced, providing each user with the ability to select the beam, the update rate, and the attenuation level in the digitizing hardware. In addition each user calibrates the hardware for his beam. A description of the system architecture will be presented. 6 refs., 4 figs.
1985-04-01
Energy Technology Data Exchange (ETDEWEB)
Martin Marietta Energy Systems, Inc. (Energy Systems) manages a closed hazardous waste disposal unit, Chestnut Ridge Security Pits (CRSP), in the form of two trenches and several auger-holes, located on top of the eastern portion of Chestnut Ridge at the Department of Energy (DOE) Oak Ridge Y-12 Plant in Tennessee. The groundwater monitoring system for the unit presently consists of a network of upgradient and downgradient monitor wells. To investigate the discharge of groundwater to springs and streams. An initial dye-tracer study was conducted during the driest part of 1990. The dye was detected at some of the monitoring sites, but verification was necessary due to the proximity of some sites to extraneous dye sources. A second dye-tracer was conducted during the wet weather season. The actual test commenced during the first week of February 1992 with a 4-week baseline monitoring period to determine ...
1992-11-01
British Library Electronic Table of Contents (United Kingdom)
In this paper, a robust water level control system for the horizontal steam generator (SG) using the quantitative feedback theory (QFT) method is presented. To design a robust QFT controller for the nonlinear uncertain SG, control oriented linear models are identified. Then, the nonlinear system is modeled as an uncertain linear time invariant (LTI) system. The robust designed controller is applied to the nonlinear plant model. This nonlinear model is based on a locally linear neuro-fuzzy (LLNF) model. This model is trained using the locally linear model tree (LOLIMOT) algorithm. Finally, simulation results are employed to show the effectiveness of the designed QFT level controller. It is shown that it will ensure the entire designer's water level closed loop specifications.
2011-01-01
Feedwater control device for a reactor
International Nuclear Information System (INIS)
Purpose: To eliminate the water level deviation due to the recycling flowrate, as well as enable a stable control to a reference value even upon changes in the recycling flowrate caused by the variation in the opening degree of a minimum flow valve. Constitution: Reactor recycling system comprises a feedwater pump, a flowrate control valve, a reactor water level detector, and a minimum flow line and a minimum flow valve for preventing the overheating of the feedwater pump at a low flowrate. A flowrate compensator is further disposed, in which a recycling flowrate signal is subtracted from a pump flow rate signal and the result is fedback as a compensated pump flowrate signal. This enables the control system to operate at a rapid response for suppressing the effect of the recycling flowrate as external disturbance, whereby the water level in the reactor can be ...
1981-11-18
Energy Technology Data Exchange (ETDEWEB)
The K site near Seoul began landfilling in 1992. The landfilled wastes include municipal solid waste (66.4%), construction residues (20.4%), water and wastewater sludges (trace levels), and hazardous waste (trace levels). The water content of the municipal solid waste is very high (47.3%); as a result, the leachate level (average E.L.) of the landfill, the design value of which is 7.0 m, was measured at 10.3 m in January 1995 and is increasing. The increase of leachate level in the landfill site causes a problem with slope stability. The leachate level at each disposal stage divided by the intermediate cover layer was calculated with the HELP (Hydrologic Evaluation of Landfill Performance) model and calibrated with the data measured from February 1993 to June 1995. Also, the hydraulic conductivities of the waste layer and the intermediate ...
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
This document describes products which the US EPA Wetlands Research Program proposes to develop during the years 1989-1994. The general protocols used to develop these products are also described. All these products are intended to address concerns about the wetlands and water quality, and are part of a larger set of products EPA is developing to deal with other aspects of wetlands. EPA's highly interrelated concerns about wetlands and water quality can be generally categorized as follows: water quality criteria to protect wetland function; ecological status of the wetland resource; and waste-assimilation limits of wetlands.
1989-04-01
British Library Electronic Table of Contents (United Kingdom)
For optimal performances, proton exchange membrane fuel cells require fine water and thermal management. Accurate modelling of the physical phenomena occurring in the fuel cell is a key issue to improve fuel cell technology. Here, an analytic steady state diphasic 2D model of heat and mass transfer is presented. Through this model, the aim of this work is to study the influence of local events on the global performances of a fuel cell. A part of the complete model is a microscopic representation of the coupling between water transport and charge transfers in the electrodes. The thickness of the liquid layer around the reactive agglomerates is deduced from the saturation. The evolution of the quantity of water within the catalyst layer is monitored and its influence on the global performanc...
2010-01-01
Formation of complex Langmuir and Langmuir-Blodgett films of water soluble rosebengal
British Library Electronic Table of Contents (United Kingdom)
This communication reports the formation of complex Langmuir monolayer at the air-water interface by charge transfer types of interaction with the water soluble N-cetyl Formula Not Shown -trimethyl ammonium bromide (CTAB) molecules doped with rosebengal (RB), with the stearic acid (SA) molecules of a preformed SA Langmuir monolayer. The reaction kinetics of the formation of RB-CTAB-SA complex monolayer was monitored by observing the increase in surface pressure with time while the barrier was kept fixed. Completion of interaction kinetics was confirmed by FTIR study. This complex Langmuir films at the air-water interface was transferred onto solid substrates at a desired surface pressure to form multilayered Langmuir-Blodgett films. Spectroscopic characterizations reveal some molecular lev...
2007-01-01
Anxiety for Norwegian nature being sacrificed for climate; Frykter norsk natur ofres for klima
Energy Technology Data Exchange (ETDEWEB)
While hydropower industry finds great profit opportunities in increased effective production, the host municipals have anxiety for great environmental damages. Regulations of water reservoirs. Differences between highest and lowest planned water level are specified in regulations for water reservoirs. The background for these regulations are both esthetic and environmental. (AG)
2009-07-01
Energy Technology Data Exchange (ETDEWEB)
Using the past diffusion trends of four renewable energy technologies for irrigation water pumping in India (SPV pumps, windmill pumps and biogas/producer gas driven dual fuel engine pumps), results of an attempt to project their future dissemination levels, have been presented in this study. The likely contribution of the renewable energy options considered in the study to the projected energy demand for irrigation water pumping in India has been estimated. Estimates of the associated investment requirements taking into account the learning effect have also been presented. (author)
2005-12-01
Feedwater control device of the steam generator in an atomic power station
International Nuclear Information System (INIS)
Purpose: In a case of automatically controlling the water level at the time of generating a lower power, to impact the followability of the control necessary for the power variation of the steam generator thereby to obtain good controllability. Constitution: A signal of deviation of water level of a steam generator and its set value and a signal of a difference between the temperature of the primary coolant in the high temperature side pipeline and that of the primary coolant in the low temperature side pipeline are used to automatically or manually control the flow quantity of water fed to the steam generator. (Yoshihara, H.).
Energy Technology Data Exchange (ETDEWEB)
A series of copolymers based on the cellulose acetate/propionate-g.co-acrylic acid system has been prepared under radiation-induced control. These copolymers have been assessed for their water-retention capacity both in an unmodified state and after ''decrystallization'' or ''neutralization'' treatments. The grafting of acrylic acid onto the cellulose acetate/propionate had little effect on the water retention power of the cellulose acetate/propionate. However, improvements to the water retentivity was obtained after ''decrystallization'' procedures had been carried out on the copolymers using selected alkali metal salts with methanol as the continuous medium. The water-retentivity of the copolymers increased with increase in the extent of grafting, though the effect is less pronounced at high ...
1990-01-01
Radon measurements at the FEMP
Energy Technology Data Exchange (ETDEWEB)
Environmental radon monitoring activities at the DOE Fernald Environmental Management Project (FEMP) have been conducted extensively since the early 1980`s. Monitoring has been conducted at ambient concentration levels (< 1 pCi/L Rn-222), inside buildings, and at significantly elevated levels (hundreds of thousands pCi/L Rn-222) within the K-65 silo that store concentrated radium bearing wastes. The purpose of this paper/presentation is to present and discuss some of the difficulties encountered/solutions (e.g. reliability, detection limits, affects of environmental factors, data transfer, etc.) that have been discovered while taking measurements using both alpha track-etch passive integrating detectors and alpha scintillation real-time detectors. A short summary and conclusion section is provided following each topic presented.
1993-08-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this paper is to check up a GPS (global positioning system) impact on scientific research activities of the Geodetic Society of Japan. First, it is mentioned that the conventional geoid-based concept of 'gravity anomaly' should be changed to a new definition, according to the GPS-determined ellipsoidal height system. Secondly, the results of many experiments, which have been made to monitor ocean-plate motions relative to the Japanese island-arcs, demonstrate that GPS is a powerful tool for obtaining temporal changes in horizontal displacement induced by the plate motion. Therefore, it is suggested that terrestrial measurements, such as triangulation and long-range leveling, would be replaced by GPS measurements in near future. Moreover, it is pointed out that GPS geodesy should play an important role in monitoring secular sea level trend due to global warming of the ...
1992-12-25
Energy Technology Data Exchange (ETDEWEB)
Detailed, complete, timely and reliable statistics are essential to monitor the energy situation at a country level as well as at an international level. Energy statistics on supply, trade, stocks, transformation and demand are indeed the basis for any sound energy policy decision. For instance, the market of oil -- which is the largest traded commodity worldwide -- needs to be closely monitored in order for all market players to know at any time what is produced, traded, stocked and consumed and by whom. In view of the role and importance of energy in world development, one would expect that basic energy information to be readily available and reliable. This is not always the case and one can even observe a decline in the quality, coverage and timeliness of energy statistics over the last few years.
2010-07-01
Application of Risk Management for Control and Monitoring Systems
This paper presents an application of the state of the art and new trends for risk management of safety-related control and monitoring systems, currently applied in the industry. These techniques not only enable to manage safety and reliability issues but they also help in the control of quality and economic factors affected by the availability and maintenance of the system. The method includes an unambiguous definition of the system in terms of functions and a systematic analysis of hazardous situations, undesired events and possible malfunctions. It also includes the identification and quantification of the risk associated to the system. The required risk reduction is specified in terms of safety integrity levels. The safety integrity level results in requirements, preventive measures, possible improvements and recommendations to assure the satisfactory management of the risk.
2001-01-01
International Nuclear Information System (INIS)
This work describes an experimental verification of the two-photon dose calculation engines available on the Helax-TMS (version 6.1) commercial radiotherapy treatment planning system. The performance of the pencil beam convolution and the collapsed cone superposition algorithms was examined for 4, 6, 15 MV beams, under a range of clinically relevant irradiation geometries. Comparisons against measurements were carried out in terms of absolute dose, thus assessment of the accuracy of monitor unit (MU) calculations was also carried out. Results show that both algorithms agree with measurement to acceptable tolerance levels in most cases in homogeneous water-equivalent media irradiated under full scatter conditions. The collapsed cone algorithm slightly overestimates the penumbra width and this is mainly due to discretization effects of the fluence matrix. The accuracy of this algorithm strongly depends on the resolution of ...
2003-09-07
Assessment of tritium in the Savannah River Site environment
Energy Technology Data Exchange (ETDEWEB)
This report is the first revision to a series of reports on radionuclides inn the SRS environment. Tritium was chosen as the first radionuclide in the series because the calculations used to assess the dose to the offsite population from SRS releases indicate that the dose due to tritium, through of small consequence, is one of the most important the radionuclides. This was recognized early in the site operation, and extensive measurements of tritium in the atmosphere, surface water, and ground water exist due to the effort of the Environmental Monitoring Section. In addition, research into the transport and fate of tritium in the environment has been supported at the SRS by both the local Department of Energy (DOE) Office and DOE`s Office of Health and Environmental Research.
1993-10-01
Mixed Waste Management Facility (MWMF) groundwater monitoring report, second quarter 1992
Energy Technology Data Exchange (ETDEWEB)
During second quarter 1992, tritium, trichloroethylene, tetrachloroethylene, chloroethene, antimony, 1,1-dichloroethylene, lead, nonvolatile beta, radium-228, thorium-228, or total alpha-emitting radium (radium-226 and radium-228) exceeded the US Environmental Protection Agency Primary Drinking Water Standards (PDWS) in groundwater samples from monitoring wells at the Mixed Waste Management Facility (MWMF) and adjacent facilities. Tritium and trichloroethylene were the most widespread constituents; 55 (48%) of the 115 monitored wells contained elevated tritium activities, and 23 (20%) wells exhibited elevated trichloroethylene concentrations. Sixty-three downgradient wells screened in Aquifer Zone IIB2 (Water Table), Aquifer Zone IIB[sub 2] (Barnwell/McBean), and Aquifer Unit IIA (Congaree) contained concentrations of tritium, trichloroethylene, tetrachloroethylene, chloroethene, antimony, ...
1992-09-01
Distinction of mining lakes in central Germany with remote sensing methods
Energy Technology Data Exchange (ETDEWEB)
Mining lakes are of a world-wide challenging problem caused by the well known acid mine drainage (AMD) and the dynamics of it. In the past, there was no possibility to monitor these mining lakes for an investigation of chemical and biological parameters. But, in general, remote sensing methods are suitable for a monitoring of natural lakes, and now, at the first time, those can be used for a distinction of acid mining lakes in central Germany into different types. In acid mining lakes unusual absorption and scattering properties exist due to the water constituents which are quite different in their optical properties to those of natural lakes. The artificial lakes show high concentrations of metal ions and compounds. This fact was used to discriminate the mining lakes into initial stage, early stage, transitional state and late state. The result is a map of the area where the mining lakes are presented at their current ...
2001-07-01
Measures for reliability improvement of on-site power plant at steel works
Energy Technology Data Exchange (ETDEWEB)
This report describes the arrangement and features of the Ogishima thermal power plant facilities, as well as activities being performed there for operation control, regular inspection and improvement in reliability. The power plant uses about 48 percent of the by-product gas as its fuel to supply about 81 percent of the required power. Operation of the No. 1 unit started in 1976. Currently, the plant has three units, each with an output of 125MW. Each unit consists of a natural circulation boiler with a maximum evaporation capacity of 410 ton/hour and a reheat regenerative condensing turbine with a main vapor pressure of 127 kg/cm/sup 2/G. Techniques used for water properties control and combustion control are also described. In the plant, convetional time management integrity techniques are now being replaced by state management integrity techniques that determines the deterioration tendency in separate sections of the facilities which are divided in ...
1988-04-15
Development and manufacture of tritium-in-air monitors for Indian PHWRs
International Nuclear Information System (INIS)
Tritium, a beta emitting gas at room temperature causes a biological hazard in the locations where it is present beyond acceptable limits. The hazard can be due to inhalation, and absorption by skin. Hence is the necessity of Tritium monitoring instruments/systems for ensuring safety in the PHWRs and the nuclear research plants and laboratories. It is desirable that the instruments address satisfactorily to certain factors like the following: (i) Wide range of Tritium concentrations - 1 to 104 DAC ( Derived Air Concentration) (ii) On-line monitoring features (iii) Small response time (On-spot instantaneous measurements) (iv) Portability (v) Mitigation of memory effects. This paper presents an overview of the Online Tritium in Air Monitoring Systems manufactured by ECIL for Pressurised Heavy Water Reactors at Tarapur, Kaiga, and Rawatbhata. Significant aspects of design, function, testing, limitations of ...
2009-10-01
Uptake of atmospheric tritium by market foods
Energy Technology Data Exchange (ETDEWEB)
In this paper uptake of tritium by market foods from tritiated water vapor in the air is investigated using cereals and beans purchased in Deep River, Canada. The concentrations of tissue free water tritium (TFWT) and organically bound tritium (OBT) range from 12 to 79% and from 10 to 38% respectively, of that estimated for atmospheric water vapor of the sampling month. The specific activity ratios of OBT to TFWT were constant for cereals, but variable for beans. The elevated OBT was shown to be the result of isotopic exchange of labile hydrogen by the fact that washing the foods with tritium free-water reduced their tritium contents to levels characteristic of their production sites.
1992-03-01
Longer life for steam generators
Eight years ago, corrosion and tube denting seriously threatened the reliability and design life of steam generators, especially for closed loop arrangements in pressurized water reactors (PWRs). Concentrated research by the Steam Generator Owners Group (SGOG) diagnosed the causes and produced effective solutions, notably guidelines for water chemistry control in the secondary loop. The guidelines recommend specific levels of water impurities and remedial actions to prevent cooling-water leaks in the condenser, prevent air leaks, limit corrosion product buildup, and remove some impurities while neutralizing others. Continued research in SGOB-II is investigating intergranular corrosion and stress corrosion cracking. 3 figures.
1984-10-01
Longer life for steam generators
International Nuclear Information System (INIS)
Eight years ago, corrosion and tube denting seriously threatened the reliability and design life of steam generators, especially for closed loop arrangements in pressurized water reactors (PWRs). Concentrated research by the Steam Generator Owners Group (SGOG) diagnosed the causes and produced effective solutions, notably guidelines for water chemistry control in the secondary loop. The guidelines recommend specific levels of water impurities and remedial actions to prevent cooling-water leaks in the condenser, prevent air leaks, limit corrosion product buildup, and remove some impurities while neutralizing others. Continued research in SGOB-II is investigating intergranular corrosion and stress corrosion cracking. 3 figures.
Tritium in surface waters, tap water and in precipitation in Poland during the 1994-1999 period
International Nuclear Information System (INIS)
Concentrations of tritium in environmental waters (precipitation, rivers, lakes, tap water) have been determined using electrolytic enrichment and liquid scintillation counting. In waters of big rivers (the Vistula and the Odra rivers), lakes and tap water the annual average concentrations were similar to each other being from 1.4 to 1.9 Bq x dm"-"3. These concentrations were similar to those in the precipitation in which they ranged from 1.7 to 2.2 Bq x dm"-"3. The lowest tritium concentrations were found in waters of the Seashore Region rivers (average for 1994-1999 was 1.1 Bq x dm"-"3). The tritium concentrations in surface waters and in precipitation are still higher than that of natural level. The data obtained show that tritium concentration in the water of rivers might depend on the size of drainage area. The ...
2001-01-01
Low temperature humidification dehumidification desalination process
Energy Technology Data Exchange (ETDEWEB)
The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling ...
2006-03-01
Low temperature humidification dehumidification desalination process
International Nuclear Information System (INIS)
The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling ...
2006-03-01
Energy Technology Data Exchange (ETDEWEB)
A guidance document on the instrumentation for monitoring and control of cycle chemistry for the steam-water circuits of fossil-fired and combined-cycle power plants was developed within the IAPWS Power Cycle Chemistry Working Group. This technical guidance document has been authorized by the International Association for the Properties of Water and Steam (IAPWS) at its meeting in Doorwerth, The Netherlands, 6-11 September, 2009, for issue by its Secretariat. The members of the IAPWS are: Britain and Ireland, Canada, the Czech Republic, Denmark, France, Germany, Greece, Japan, Russia, and the United States of America, and the associate members Argentina and Brazil, Italy, and Switzerland. In order to achieve suitable chemical conditions in steam-water circuits it is essential to establish reliable monitoring of key parameters on every plant. This enables the demonstration of ...
2009-10-15
Anode wire ageing in proportional detectors at the BAC calorimeter of the ZEUS experiment
Energy Technology Data Exchange (ETDEWEB)
Experimental results of ageing effects in proportional counters are presented. The measurements were carried out for 158 ZEUS-BAC gas system monitoring counters. Deterioration of the pulse height distribution in azimuth and along the anode wire are presented. The influence of water admixture on counting gas is also described. (orig.).
1997-06-21
Energy Technology Data Exchange (ETDEWEB)
The application of airborne sensors for providing environmental assessment and monitoring of a test site in an open cast mining area that is part of a lignite deposit in central Germany is described. Hyperspectral remote sensing data from three different sensors were tested. The hyperspectral scanner data was suitable for classification of different sediments and vegetation types and the water chemistry of residual mining lakes. Summary form only. 1 tab.
1999-07-01
Sandia National Laboratories/California site environmental report for 1997
Energy Technology Data Exchange (ETDEWEB)
Sandia National Laboratories (SNL) is committed to conducting its operations in an environmentally safe and sound manner. It is mandatory that activities at SNL/California comply with all applicable environmental statutes, regulations, and standards. Moreover, SNL/California continuously strives to reduce risks to employees, the public, and the environment to the lowest levels reasonably possible. To help verify effective protection of public safety and preservation of the environment, SNL/California maintains an extensive, ongoing environmental monitoring program. This program monitors all significant effluents and the environment at the SNL/California site perimeter. Lawrence Livermore National Laboratory (LLNL) performs off-site external radiation monitoring for both sites. These monitoring efforts ensure that emission controls are effective in preventing contamination of the ...
1998-06-01
Kokanee Stocking and Monitoring, Flathead Lake, 1993-1994 Annual Report.
Energy Technology Data Exchange (ETDEWEB)
One mitigation goal of the Hungry Horse Dam fisheries mitigation program, funded by the Bonneville Power Administration, is to replace lost production of 100,000 adult kokanee in Flathead Lake. The mitigation program calls for a five-year test to determine if kokanee can be reestablished in Flathead Lake. The test consists. of annual stocking of one million hatchery-raised yearling kokanee. There are three benchmarks for judging the success of the kokanee reintroduction effort: (1) Post-stocking survival of 30 percent of planted kokanee one year after stocking; (2) Yearling to adult survival of 10 percent (100,000 adult salmon); (3) Annual kokanee harvest of 50,000 or more fish per year by 1998, with an average length of 11 inches or longer for harvested fish, and fishing pressure of 100,000 angler hours or more. Kokanee were the primary sport fish species in the Flathead Lake fishery in the early 1900s, and up until the late 1980s when the population rapidly declined in numbers and ...
1995-07-01
International Nuclear Information System (INIS)
Manganese is a common contaminant of mine water and other waste waters. Due to its high solubility over a wide pH range, it is notoriously difficult to remove from contaminated waters. Previous systems that effectively remove Mn from mine waters have involved oxidising the soluble Mn(II) species at an elevated pH using substrates such as limestone and dolomites. However it is currently unclear what effect the substrate type has upon abiotic Mn removal compared to biotic removal by in situ micro-organisms (biofilms). In order to investigate the relationship between substrate type, Mn precipitation and the biofilm community, net-alkaline Mn-contaminated mine water was treated in reactors containing one of the pure materials: dolomite, limestone, magnesite and quartzite. Mine water chemistry and Mn removal rates were monitored over a 3-month ...
2006-08-01
Energy Technology Data Exchange (ETDEWEB)
In France, groundwater usage represents 40 per cent of volumetric use, outside of thermal power plants. Groundwater represents 60 per cent of domestic and public use, 40 per cent in the industrial sector, and is increasing in the agricultural sector where it accounts for 20 per cent. Groundwater withdrawal in France has slightly increased over the last twenty years and benefited the agricultural sector. Availability throughout the territory, the consistency of resupply and natural quality has rendered groundwater a prevailing source for drinking water. Water protection and management is important and led to the adoption of legislative and regulatory measures. The Mining Code (Code minier) allows for exploitation of underground resources starting at 10 metres. The Rural Code (Code rural) mandates the declaration of public utility for water collection for the public. Protection areas are to be provided under the Public Health ...
2001-07-01
Monitoring DC partial discharges with Nilsson Plate
Energy Technology Data Exchange (ETDEWEB)
The Nilsson Plate High Frequency Adaptation of the Static Electrification Monitor developed by Electric Research and Management, Inc. for EPRI has demonstrated that the Nilsson Plate can be utilized as a practical high frequency antenna to record partial discharge activity within a transformer. Tests in the ABB factory at Muncie, IN on a 650 MVA, 345/20.9 kV, three-phase unit step-up transformer for TU Electric showed the Nilsson plate detecting partial discharge activity. Although this test was the first attempt at using the Nilsson plate in this manner, and in spite of higher than expected electrical noise levels, the data demonstrated that partial discharges can be detected. The tests also demonstrated that corona activity external to the transformer was not recorded by the plate. Some development work needs to be completed to eliminate the noise source from other monitors on the Static Electrification ...
1995-05-01
Methodology for designing air-quality-monitoring networks. 1. Theoretical aspects
Energy Technology Data Exchange (ETDEWEB)
An objective methodology is presented for determining the number and disposition of ambient air-quality stations in a monitoring network for the primary purpose of compliance with air-quality standards. The methodology utilizes a data base with real or simulated data from an air quality dispersion model for application with a two-step process for ascertaining the optimal monitoring network. In the first step, the air-quality patterns in the data base are collapsed into a single composite pattern through a figure-of-merit (FOM) concept. The most-desirable locations are ranked and identified using the resultant FOM fields. In the second step the network configuration is determined on the basis of the concept of spheres of influence (SOI) developed from cutoff values of spatial-correlation coefficients between potential monitoring sites and adjacent locations. The minimum number of required stations is then determined by ...
1986-01-01
A Cognitive Approach to Network Monitoring in Heterogeneous Environments
DEFF Research Database (Denmark)
Introducing intelligence by means of cognition for managing, protecting, processing, and delivering of information in mobile communication systems is the way towards ubiquitous, converged and secure communications. In this context, this paper introduces the concept of quality of information (QoI). QoI means QoS while all the requirements for dependability, security, privacy and trust are satisfied at the highest possible level. This work proposes and describes an approach to network monitoring in a heterogeneous communication environment based on use of cognitive techniques and learning predictive algorithms (e.g., fuzzy logic). These methodologies are used to create an autonomy in the decision making process that is based on the calculation of key performance indicators (KPIs), which in their turn would trigger the needed radio resource management algorithms. The expected output is an improved network performance in terms of maximized ...
2007-01-01
Simplified RF power system for Wideroe-type linacs
Energy Technology Data Exchange (ETDEWEB)
The RF system for the SuperHILAC injector linac was designed and constructed for minimum system complexity, wide dynamic range, and ease of maintenance. The final amplifier is close coupled to the linac and operates in an efficient semilinear mode, eliminating troublesome transmission lines, modulators, and high level regulators. The system has been operated at over 250 kW, 23 MHz with good regulation. The low level RF electronics are contained in a single chassis adjacent to the RF control computer, which monitors all important operating parameters. A unique 360/sup 0/ phase and amplitude modular is used for precise control and regulation of the accelerating voltage.
1981-03-01
Energy Technology Data Exchange (ETDEWEB)
A thermal-resistant radiation sensing system using optical fiber has been developed. The system is for monitoring progress of chemical decontamination and able to measure the gamma-ray level in a hot solution of decontamination chemicals in situ. Our sensor head makes use of thermal-resistant NaI (T1) and it is connected to an optical fiber bundle. Scintillation photons pass from the NaI (T1) into the end of the bundle. This part of the system can withstand temperatures of over 100degC. At the far end of the optical fiber bundle, the scintillation photons are converted into fluorescent photons using a wavelength-shifting fiber. These photons are transferred to a distant photomultiplier tube through two thin transparent optical fibers. Furthermore, we propose a self-compensation technique for the dependence of scintillator sensitivity on. This compensation method is based on the correlation between temperature, sensitivity, and scintillation ...
1999-07-01
Some sensitivities during a LWR severe core-damage sequence
International Nuclear Information System (INIS)
Stable boiloff of core water during a severe LWR accident, that is, boiloff driven only by the decay power generated below the water level, is tractable analytically and is relatively insensitive to axial power distribution. As might be expected, calculated accident event times are sensitive to the fidelity of the decay power model. During later stages of boiloff, heat transfer or transport of energy from above the water level to the residual water can result in an unstable condition during which the boiloff rate increases greatly. The unstable boiloff phenomenon illustrates the highly nonlinear influence of core heat transfer during meltdown and emphasizes the great accuracy requirements which attend the modeling of the accident during periods of enhanced heat transfer when significant zirconium oxidation is possible.
1981-12-04
Water conservation in agriculture -a step in combating the water crisis
International Nuclear Information System (INIS)
In Pakistan, the agricultural sector is the largest water user with 95%, leaving only marginal quantities for households and industry. On one hand, agriculture is a very important sector in Pakistan's economic development, contributing about 23 % to the national GDP -but industry contributes slightly more using only about 2 % of the available water resources. As Pakistan faces a growing problem of water shortage, significant achievements in water conservation have to be materialized, predominantly on the agricultural sector. There is scope for a higher degree of efficiency in water use, as water losses, namely in irrigation, are still rather high. There is another good reason for water conservation in agriculture: Over-irrigation results in rising water tables and increased soil salinity, which has reduced Pakistan's ...
2004-06-07
British Library Electronic Table of Contents (United Kingdom)
Possible factors regulating phytoplankton variability in the Arabian (Persian) Gulf were analyzed on the basis of satellite observations and meteorological data (1997-2009), including remotely-sensed chlorophyll a concentration (CHL), sea surface temperature, wind, solar radiation, precipitation, and aerosols. Shallow waters of northwestern Gulf influenced by Shatt Al-Arab River discharge were more productive than open Gulf waters, although seasonal CHL patterns in this and other shallow regions looked unrealistic likely because the CHL signal was obscured by bottom reflection. Therefore our further analyses focused on the open Gulf waters, which show a subtropical seasonal CHL cycle with maximum in winter and minimum in spring-summer. This cycle, however, was decoupled from the seasonal e...
2010-01-01
Subcriticality calculations for the FFTF reverse approach to critical experiment
The reverse approach to critical (RAC) experiments were performed in the ZPR-IX critical facility at Argonne National Laboratory. One of the major objectives of this project is to determine the adequacy of the low-level flux monitor (LLFM) detectors for initial loading of the Fast Flux Test Facility (FFTF). 5 references. (auth)
1975-01-01
Energy Technology Data Exchange (ETDEWEB)
The paper deals with the disposal of radioactive waste and the plans for dealing with solid wastes of intermediate and low levels of activity, which are the responsibility of NIREX. NIREX is an executive body which co-ordinates the waste-disposal plans of the main radioactive waste producers. The disposal routes for the active wastes are described including the deep disposal of wastes containing material that will remain active for thousands of years. Requirements for deep burial are outlined with reference to the geology and hydrogeology of the site. Monitoring, maintenance and surveillance are mentioned for the protection of the public.
1984-02-01
Energy Technology Data Exchange (ETDEWEB)
Tests based on teaching aims, which can be used for objective determination of the level of knowledge of technical college and polytechnic students, are developed at the vocational training centre of the DMT. The data are gathered completely anonymously by a computer program and evaluated economically. (orig.)
1993-12-09
International Nuclear Information System (INIS)
Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).
1980-01-01
Incidents of major damage to steam turbines
International Nuclear Information System (INIS)
The author furnishes a review of incidents of major damage to high-output steam turbines. At the same time, he thereby underlines the call for an improvement in the exchange of experience on such damage and its causes at international level. Only the careful observance of past damage experience - including that of foreign manufacturers and operators - complete and modern monitoring equipment and the painstaking evaluation of all data furnished by such equipment can keep the risk of new technical development within economically tolerable limits. (orig.).
Electrical equipment of the Marchtrenk power station on the river Traun
Energy Technology Data Exchange (ETDEWEB)
By way of introduction, the author describes the electrical equipment of the power station on the River Traun and then lists the main features of the electrical systems such as generators, transformers, the power transmission systems as, e.g., the generator leads, the 8 kV switch plant, the 110 kV oil-filled cable as well as the station-service, control, protection and monitoring systems. The control of the headwater level and of the mechanical systems of the barrage is described in detail.
1982-03-01
This report contains data collected on a monthly basis over the period April, 1973 - April, 1975 for dustfall particulates, sodium and chloride and SO2 levels obtained from 12 monitoring sites near the Chalk Point Generating Station operated by PEPCO and ...
1976-01-01
A non-invasive approach for the determination of rumen pH
Environmental Research Database
DescriptionAt present, measurement of rumen pH for differnt diets and feeding regimes is only possible through direct sampling of the rumen fluid. Such invasive procedures are not practical at the farm level and they have ethical implications for research programmes. This approach also has limitations to its reliability due to spatial variations in acidity within the rumen. Mathematical modelling offers a non-invasive real-time alternative for monitoring rumen pH, and the purpose of the research propose [continued...
2004-01-31
Natural radionuclides in drinking water in Argentina
International Nuclear Information System (INIS)
As part of the national survey to evaluate natural radioactivity in the environment, concentration levels of natural uranium and "2"2"6Ra have been analyzed in over 300 drinking water samples taken from different locations in Argentina. "2"2"6Ra was determined by "2"2"2Rn emanation and liquid scintillation counting, and natural uranium by a fluorimetric procedure. Values ranging from 0.03 to 24 #mu#g.l"-"1 of natural uranium and from 0.06 to 50 #mu#g.l"-"1, were measured on drinking water samples taken from tap water systems and private wells, respectively. Concentrations up to 15 mBq.l"-"1 and to 22 mBq.l"-"1 of "2"2"6Ra were found in drinking water samples taken from tap water systems and private wells, respectively. These values are compared with the reference values accepted for drinking water. Based on the water ...
2000-05-01
Ventilation test at Mont Terri. Geoelectric monitoring of the opalinus clay desaturation. Phase 2
Energy Technology Data Exchange (ETDEWEB)
Between December 2001 and May 2004, a ventilation experiment (VE) was performed in the Mont Terri Underground Research Laboratory (URL) and co-financed by the Commission of the European Communities. The objective was to investigate the desaturation of consolidated clay formations in consequence of the ventilation of underground openings of a repository in such a formation. The results of the geoelectric measurements performed in the second phase of the Mont Terri ventilation test can be summarized as follows: Geoelectric tomography has been found suitable for monitoring ventilation-induced saturation changes in the Opalinus clay. During ventilation with dry air a desaturation down to below 50% could be detected in both desaturation cycles. The desaturated zone extends less than 0.5 m into the rock around the microtunnel. During the second resaturation phase, ventilation with humid air led to quick resaturation at the tunnel surface, while resaturation of the rock ...
2008-04-15
Ventilation test at Mont Terri. Geoelectric monitoring of the opalinus clay desaturation. Phase 2
International Nuclear Information System (INIS)
Between December 2001 and May 2004, a ventilation experiment (VE) was performed in the Mont Terri Underground Research Laboratory (URL) and co-financed by the Commission of the European Communities. The objective was to investigate the desaturation of consolidated clay formations in consequence of the ventilation of underground openings of a repository in such a formation. The results of the geoelectric measurements performed in the second phase of the Mont Terri ventilation test can be summarized as follows: Geoelectric tomography has been found suitable for monitoring ventilation-induced saturation changes in the Opalinus clay. During ventilation with dry air a desaturation down to below 50% could be detected in both desaturation cycles. The desaturated zone extends less than 0.5 m into the rock around the microtunnel. During the second resaturation phase, ventilation with humid air led to quick resaturation at the tunnel surface, while resaturation of the rock ...
International Nuclear Information System (INIS)
Specific structure of biota community condition can used as indicator for the ecosystem stability value or the waters pollution level where the aquatic biota exist. the macro invertebrates as bio indicator organism can used to assess the upper Cisadane Sub River Basin water quality. The grouping and calculation result from family number, Ept presences (sensitive macro invertebrate), Diversity index (H"'), DO value and TOC value showed 5 criteria of water quality as reference site. This criteria is used to determine water quality level from ten branches of rivers in the upper Cisadane Sub River Basin, Cijeruk districts. The biotic index calculation for ASPT (Average Score Per Taxon) and T and T (index Trihadiningrum and Tjindronegoro) is used to asses water quality based on macro invertebrate composition indicator. Both biotic index system ...
2001-11-01
Hydrogeochemistry of seasonal variation of Urmia Salt Lake, Iran
UK PubMed Central (United Kingdom)
Urmia Lake has been designated as an international park by the United Nations. The lake occupies a 5700 km2 depression in northwestern Iran. Thirteen permanent rivers flow into the lake. Water level...Full Text Available
International Nuclear Information System (INIS)
A mathematical model is described for determining the level profile along the length of heat exchange tubes in a horizontal steam generator, and for determining the conditions in the steam cushion under the perforated sheet. The water level area is divided in the model into 36 partial elements; for analysis of the conditions under the level, the steam-water space is divided into four areas. The results of the calculations were compared with measurement results for the steam generator rated values. Very good agreement was found. The results show that, among others, the supply water distribution very much affects the conditions in the area of the steam cushion and of the bubble vacuum. Also, the average steam load of the inner bundle tubes is significantly higher than that of the outer bundles. It was also shown that permanent steam generator operation with ...
Atomistic Simulation of Water Percolation and Proton Hopping in Nafion Fuel Cell Membrane
Energy Technology Data Exchange (ETDEWEB)
We have performed a detailed analysis of water clustering and percolation in hydrated Nafion configurations generated by classical molecular dynamics simulations. Our results show that at low hydration levels H2O molecules are isolated and a continuous hydrogen-bonded network forms as the hydration level is increased. Our quantitative analysis has established a hydration level (?) between 5 and 6 H2O/SO3- as the percolation threshold of Nafion. We have also examined the effect of such a network on proton transport by studying the structural diffusion of protons using the quantum hopping molecular dynamics method. The mean residence time of the proton on a water molecule decreases by two orders of magnitude when the ? value is increased from 5 to 15. The proton diffusion coefficient in Nafion at a ? value of 15 is about 1.1x10-5 cm2/s in agreement with experiment. The results provide ...
2010-11-04
Drying plant waste; Trocknung von Betriebsabfaellen
Energy Technology Data Exchange (ETDEWEB)
Under the repository storage conditions of Eram and Konrad, waste packages designed for permanent storage must not contain or release freely mobile liquids, except for the minimum residues attainable by reasonable efforts or unavoidable. In accordance with a directive issued by the German Federal Ministry for the Environment (BMU), waste conditioning must be carried out so as to minimize waste volumes and, if possible, on the site where the waste arises. Liquid waste is conditioned most effectively by drying. At the present time, various different processes for drying liquid waste are employed as reflected by the state of the art: The Robe process; roller drying; the RDA process; Favorit; in-drum drying; and HPA liquid waste drying with make-up feed. The HPA process offers these advantages: Drying under atmospheric conditions, which means high level of dryness (freely mobile and releasable water is removed); the residual ...
1995-11-01
Energy Technology Data Exchange (ETDEWEB)
Lower East Fork Poplar Creek (LEFPC) and its floodplain are contaminated with mercury (Hg) from ongoing and historical releases from the US Department of Energy (DOE) Oak Ridge Y-12 Plant. A remedial investigation and feasibility study of LEFPC resulted in the signing of a Record of Decision (ROD) in August 1995. In response to the ROD, soil contaminated with mercury above 400 mg/kg was removed from two sites in LEFPC and the floodplain during a recently completed remedial action (RA). The Postremediation Monitoring Program (PMP) outlined in the LEFPC Monitoring Plan was envisioned to occur in two phases: (1) a baseline assessment prior to remediation and (2) postremediation monitoring. The current report summarizes the results of the baseline assessment of soil, water, biota, and groundwater usage in LEFPC and its floodplain conducted in 1995 and 1996 by personnel of the Oak Ridge National Laboratory ...
1998-04-01
British Library Electronic Table of Contents (United Kingdom)
Coal exploitation inevitably damages the natural ecological environment through large scale underground exploitation which exhausts the surrounding areas and is the cause of surface subsidence and cracks. These types of damage seriously lower the underground water table. Deterioration of the environment has certainly an impact on and limits growth of vegetation, which is a very important indicator of a healthy ecological system. Dynamically monitoring vegetation growth under coal exploitation stress by remote sensing technology provides advantages such as large scale coverage, high accuracy and abundant information. A scatter plot was built by a TM (Thematic Mapper) infrared and red bands. A detailed analysis of the distributional characteristics of vegetation pixels has been carried out. ...
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
This poster presentation gave an overview of the subaqueous deposition of reactive mine tailings in the open trench Don Rouyn, located near Rouyn-Noranda, Quebec. The author began by providing a brief background of subaqueous mine tailing storage, and discussed the interest of the Don Rouyn trench. The site was described according to geomorphological and geological aspects. The hydrology conditions existing at the site were mentioned, and the results of the hydrology analysis performed were indicated. Close monitoring of the situation was maintained, and the chemical and physical stability of the tailings were evaluated. The conditions that prevailed both before and after the flooding of the site were explained. Water quality is being monitored, and the results obtained at this site might be used at other locations. 40 figs.
2000-07-01
Monitoring global land surface drought based on a hybrid evapotranspiration model
British Library Electronic Table of Contents (United Kingdom)
The latent heat of evapotranspiration (ET) plays an important role in the assessment of drought severity as one sensitive indicator of land drought status. A simple and accurate method of estimating global ET for the monitoring of global land surface droughts from remote sensing data is essential. The objective of this research is to develop a hybrid ET model by introducing empirical coefficients based on a simple linear two-source land ET model, and to then use this model to calculate the Evaporative Drought Index (EDI) based on the actual estimated ET and the potential ET in order to characterize global surface drought conditions. This is done using the Global Energy and Water Cycle Experiment (GEWEX) Surface Radiation Budget (SRB) products, AVHRR-NDVI products from the Global Inventory ...
2011-01-01
Application of remote sensing and geophysics to the detection and monitoring of acid mine drainage
Energy Technology Data Exchange (ETDEWEB)
The results of a study on the application of remote sensing and geophysical methods for the detection and monitoring of acid mine drainage (AMD) are summarized, with emphasis on those that appear most suitable. The study consisted of a literature review, an information survey of users and suppliers, and discussions with various experts. Space-borne sensors, airborne sensors, airborne videography and digital frame cameras, spectroradiometers, radar, and photographic data are considered. Geophysical methods are effective for measurement of sulphides, areas of active chemical oxidation, acid mine drainage, and contaminated ground water movement. The popularity and effectiveness of various geophysical methods are rated for AMD applications. 25 refs., 1 fig., 3 tabs.
1995-06-01
1983 Northern Australia mine rehabilitation workshop - papers presented
Energy Technology Data Exchange (ETDEWEB)
Papers presented at the workshop include: the longterm viability of mined land in Queensland; the determination and achievement of rehabilitation objectives: a state government objective; monitoring native vegetation in regenerated bauxite mines at Weipa: a belt transect method; rehabilitation strategies at the Collinsville open cut coal mine; the alteration of the environment by the construction and operation of the coal export facility at Abbot Point; some aspects of the premining environment at Collinsville; the prospects for long term revegetation of acid coal mine spoil and reject materials; recovery and stability in disturbed and artificially revegetated plant communities: a theoretical viewpoint; revegetation in the arid tropics: Mount Isa Mines' experience; Nabralek and its rehabilitation; rehabilitation and management strategies for acid mine wastes; the purpose and design of water quality monitoring ...
1983-01-01
In 1996, a field-scale phytoremediation demonstration project was initiated and managed by the U.S. Air Force at a site in western Fort Worth, Texas, using a plantation of 1-year-old stems harvested from branches of eastern cottonwoods during the dormant season (whips) and a plantation of 1-year-old eastern cottonwood seedlings (calipers). The primary objective of the demonstration project was to determine the effectiveness of eastern cottonwoods at reducing the mass of dissolved trichloroethene transported within an alluvial aquifer. The U.S. Geological Survey conducted a study, in cooperation with the U.S. Air Force, to determine water-level variations and their effects on tree growth and mortality and on the biogeochemical system at the phytoremediation site. As part of the study, water-level and water-quality data were collected throughout the duration of the project. This report presents ...
2004-01-01
International Nuclear Information System (INIS)
The 1993 Petroleum Hydrocarbons Conference was comprised of 3 days of technical presentations within the following topic areas: pollution prevention and cost control; development of remediation levels; free-phase and dissolved hydrocarbon contamination management; investigation and analysis of petroleum hydrocarbons; applications of computer modeling for remediation; design and implementation of bioventing; design and implementation of air sparging; soil vapor extraction as a remediation technique; and ground water remediation using natural bacteria. In addition, more than 100 leading companies in the ground water and petroleum industries participated in the Conference Exposition in which a variety of equipment and services for preventing, detecting and remediating ground water contaminated by petroleum hydrocarbons and other organic chemicals was showcased. Individual papers have been processed ...
1993-11-10
British Library Electronic Table of Contents (United Kingdom)
An experimental investigation on the air/water counter-current two-phase flow in a horizontal rectangular channel connected to an inclined riser has been conducted. This test-section representing a model of the hot leg of a pressurized water reactor is mounted between two separators in a pressurized experimental vessel. The cross-section and length of the horizontal part of the test-section are (0.25mx0.05m) and 2.59m, respectively, whereas the inclination angle of the riser is 50degree. The flow was captured by a high-speed camera in the bended region of the hot leg, delivering a detailed view of the stratified interface as well as of dispersed structures like bubbles and droplets. Countercurrent flow limitation (CCFL), or the onset of flooding, was found by analyzing the water levels mea...
2008-01-01
Real-time management of water quality in the San Joaquin River Basin, California.
Energy Technology Data Exchange (ETDEWEB)
In the San Joaquin River Basin, California, a realtime water quality forecasting model was developed to help improve the management of saline agricultural and wetland drainage to meet water quality objectives. Predicted salt loads from the water quality forecasting model, SJRIODAY, were consistently within +- 11 percent of actual, within +- 14 percent for seven-day forecasts, and with in +- 26 percent for 14-day forecasts for the 16-month trial period. When the 48 days dominated by rainfall/runoff events were eliminated from the data set, the error bar decreased to +- 9 percent for the model and +- 11 percent and +- 17 percent for the seven-day and 14-day forecasts, respectively. Constraints on the use of the model for salinity management on the San Joaquin River include the number of entities that control or influence water quality and the lack of a centralized authority to direct their activities. The ...
1997-09-01
Internal hydrological processes in suburban watersheds and their effects on water quality warrant investigation. Instrument clusters (throughfall collectors, suction lysimeters, monitoring wells, and shallow and deep piezometers) were installed at several locations within three small (50 - 70 ha) watersheds (one forested, two with different degrees of suburban development) in the Croton Watershed, southeastern New York. Biweekly and storm samples were analyzed for base cations, selected anions, and DOC over a one-year period. The topographic index (TI) quantified landscape position; flowpath analyses determined degree of development at each cluster, using % impervious cover as the metric. Water quality degradation was observed in sites with medium and high TI values; no such effect was observed along the ridges, i.e., low TI values. At medium TI values, areas with more than 5% impervious had degraded ...
2003-12-01
Biological responses to the chemical recovery of acidified fresh waters in the UK
International Nuclear Information System (INIS)
We report biological changes at several UK Acid Waters Monitoring Network lakes and streams that are spatially consistent with the recovery of water chemistry induced by reductions in acid deposition. These include trends toward more acid-sensitive epilithic diatom and macroinvertebrate assemblages, an increasing proportional abundance of macroinvertebrate predators, an increasing occurrence of acid-sensitive aquatic macrophyte species, and the recent appearance of juvenile (<1 year old) brown trout in some of the more acidic flowing waters. Changes are often shown to be directly linked to annual variations in acidity. Although indicative of biological improvement in response to improving water chemistry, 'recovery' in most cases is modest and very gradual. While specific ecological recovery endpoints are uncertain, it is likely that physical and biotic interactions are ...
2005-09-01
ESR/Alanine dosimetry on Wolsung Unit 1
Energy Technology Data Exchange (ETDEWEB)
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation ...
2007-07-01
ESR/Alanine dosimetry on Wolsung Unit 1
International Nuclear Information System (INIS)
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation ...
2007-05-10
Development of a methodology to assess organometallic effects on bioenergetic systems
Energy Technology Data Exchange (ETDEWEB)
A methodology for assessing the impact of subacute concentrations of organometallic agents on bioenergetic and oxidative damage processes in animals, cells and energy transducing subcellular organelles is being developed. Several of the assays are noninvasive and thus lend themselves to human tests. At the whole-animal level we utilize a treadmill chamber where physiological parameters of exercising animals are monitored. These include parameters of whole animals' work performance such as oxygen consumption, carbon dioxide evolution and endurance. Oxidative damage can be monitored in experiments by analyzing expired air of the animals for ethane and n-pentane. These alkanes correlate with lipid peroxidation in vivo. At the cellular and subcellular levels, respiratory activity, lipid peroxidation and free radical species are assayed. Respiratory activity is measured in muscle homogenates and ...
1981-06-01
Energy Technology Data Exchange (ETDEWEB)
Martin Marietta Energy Systems, Inc. (Energy Systems) manages a closed hazardous waste disposal unit, Chestnut Ridge Security Pits (CRSP), in the form of two trenches and several auger-holes, located on top of the eastern portion of Chestnut Ridge at the Department of Energy (DOE) Oak Ridge Y-12 Plant in Tennessee. The groundwater monitoring system for the unit presently consists of a network of upgradient and downgradient monitor wells. To investigate the discharge of groundwater to springs and streams, Energy Systems, through Geraghty and Miller, Inc., conducted an initial dye-tracer study during the driest part of 1990. The dye was detected at some of the monitoring sites, but verification was necessary due to the proximity of some sites to extraneous dye sources. Based on the results of the initial study, Energy Systems recommended to the Tennessee Department of Environment and Conservation (TDEC) in the 1990 ...
1992-11-01
Isolation condenser passive cooling of a nuclear reactor containment
Energy Technology Data Exchange (ETDEWEB)
This patent describes a nuclear system comprising a containment airspace in which a nuclear reactor pressure vessel is disposed there being a reactor core within the pressure vessel. It comprises a heat exchanger elevated a distance above the pressure vessel; a pool of water surrounding the heat exchanger; means for venting the pool of water to an environment outside the containment; a heat exchanger entry conduit within the containment, the entry conduit having an open lower end communicating with the containment space, and an upper end connected to the heat exchanger, water-containing heated fluid present in the containment airspace incident a pressure vessel loss of coolant event entering and flowing through the entry conduit into the heat exchanger for cooling the fluid to convert water vapor therein to a condensate and separate non-condensable gasses therefrom; a gravity driven cooling ...
1991-10-22
International Nuclear Information System (INIS)
Along with the shrinkage of LSI geometries, a higher quality of ultrapure water has been continuously required. Analytical technology for ultrapure water has also progressed before ultrapure water production technology improvements. In this study, we performed optimization of the analytical conditions for the direct analysis of acid droplets, and established an analytical technology for measurements of trace amounts of metallic impurities deposited on a wafer surface by means of Vapor Phase Decomposition (VPD)/Inductively Coupled Plasma Mass Spectrometry (ICP-MS). As a result, analytical technology for metallic elements of the 1x10"8 atoms/cm"2 level on wafer surface has been established. By applying analytical technology to the wafer that has been contacted with ultrapure water, a new evaluation technology for ultrapure water quality by means of wafer surface ...
2010-07-01
International Nuclear Information System (INIS)
The Gross Decontamination Experiment was conducted on various levels and surfaces of the TMI-2 Reactor Building during February and March 1982 and was designed to investigate the effectiveness of various surface decontamination techniques. The polar crane, D-rings, missile shields, refueling canal, fueling bridge, major equipment, floors and some walls were flushed with low pressure water. Water lances were directed manually and applied water at temperatures between ambient and 60"0C at a flow rate of about 95 liters per minute. In addition, floor surfaces on the 305-ft elevation and floor surfaces and major equipment on the 347-ft elevation were sprayed with high pressure water (floors in the Reactor Building are designated by their elevations above sea level). The water pressure in this case varied between 13.8 and 41.4 mPa and ...
1984-07-15
Energy Technology Data Exchange (ETDEWEB)
The previous judgment of eutrophic state, once proposed for the Trasimeno Lake (Umbria region, Italy), has been revised. According to Vollenweider-OECD classification criterion, the lake waters are at present to be classified as mesotrophic waters, with phosphorus limitation. However this level of moderate productivity results to be conditioned by the hydrochemical characteristics of the lake waters, that control phosphorus concentrations independently from the loading coming from the basin, and prevent dangerous and massive algal blooms. Different processes of chemical nature, regulating the phosphorus amount in the lake waters, are then reviewed: adsorption of P/P0(4) onto suspended materials, particularly clay mineral particles, and direct precipitation as hydroxylapatite or co-precipitation with carbonates, are found to be the principal mechanisms that determine chemical removal ...
1995-06-01
British Library Electronic Table of Contents (United Kingdom)
Abstract The glycosylation profile of therapeutic antibodies is routinely analyzed throughout development to monitor the impact of process parameters and to ensure consistency, efficacy, and safety for clinical and commercial batches of therapeutic products. In this study, unusually high levels of the mannose-5 (Man5) glycoform were observed during the early development of a therapeutic antibody produced from a Chinese hamster ovary (CHO) cell line, model cell line A. Follow up studies indicated that the antibody Man5 level was increased throughout the course of cell culture production as a result of increasing cell culture medium osmolality levels and extending culture duration. With model cell line A, Man5 glycosylation increased more than twofold from 12% to 28% in the fed-batch process...
2011-01-01
Radon concentrations in well water in Sichuan Province, China
International Nuclear Information System (INIS)
There are 110 million people in Sichuan Province, China. Although most of the people in cities of Sichuan use river water, which contains low levels of radon, as potable water, people in countryside and in some communities of big cities still use well water as domestic consumption. This paper reports the radon concentrations in well water investigated in four cities, i.e. Chengdu, Chongqing, Leshan and Leijiang in Sichuan Province. Of the 80 wells investigated, the radon concentrations range from 3.5 to 181.6 KBqm"-"3. Of the four cities, Chongqing has the highest well water radon concentration with the average 49.6 #+-# 54.1 KBqm"-"3 and the greatest variation. The investigation in four cities showed that the radon concentrations in well water are much higher than that in tap-water. In Chongqing where there are complex ...
This report is a compilation of the groundwater sampling results from three monitoring wells located near the Area 5 Radioactive Waste Management Site (RWMS) at the Nevada Test Site (NTS), Nye County, Nevada, for calendar year 2007. The NTS is an approximately 3,561 square kilometer (1,375 square mile) restricted-access federal installation located approximately 105 kilometers (65 miles) northwest of Las Vegas, Nevada (Figure 1). Pilot wells UE5PW-1, UE5PW-2, and UE5PW-3 are used to monitor the groundwater at the Area 5 RWMS (Figure 2). In addition to groundwater monitoring results, this report includes information regarding site hydrogeology, well construction, sample collection, and meteorological data measured at the Area 5 RWMS. The disposal of low-level radioactive waste and mixed low-level radioactive waste at the Area 5 RWMS is regulated by U.S. Department of Energy (DOE) ...
2008-01-01
Photosynthesis and Growth of Water Hyacinth under CO2 Enrichment 1
UK PubMed Central (United Kingdom)
Water hyacinth (Eichhornia crassipes [Mart.] Solms) plants were grown in environmental chambers at ambient and enriched CO2 levels (330 and 600 microliters CO2...Full Text Available
1986-10-01
Determination of [sup 99]Tc in sea water at ultra low levels
Energy Technology Data Exchange (ETDEWEB)
A method based on the collection of [sup 99]Tc from 500 l sea water samples by anion exchange and further extraction of TcO[sub 4][sup -] into 5% triisooctylamine-xylene has been improved to include a decontamination factor 6.5x10[sup 5] for uranium. The detection limit for [sup 99]Tc is thereby reduced to 3 mBq/m[sup 3].
1994-01-20
Problems of air pollution monitoring
Energy Technology Data Exchange (ETDEWEB)
The development of the monitoring network for background measurements of air pollution in the USSR is noted. The use of paired stations, to aid in locating permanent sites as well as for determining the local component of background air pollution, is described. Thermoelectric actionometers with five glass filters are used to measure Shupp's turbidity coefficient for estimating extinction of solar radiation due to aerosols. Sampling and chemical analysis of precipitation uses methods developed during the International Geophysical Year. An intercomparison of meteorological instruments was carried out in the USSR in 1973 and 1978. The most stable actinometer was the Linke-Foisner device. Chemical analyses of precipitation made since 1958 in the USSR show increases in air pollution levels only in particular areas.
1980-01-01
International Nuclear Information System (INIS)
This pilot project was carried out for the purpose of testing methods for active biological monitoring. It covered a period of three years (until September 1994), including two years of exposure. The measurements served to determine pollutant levels in plants used as animal fodder and dust-borne heavy metal concentrations in different sites and, on this basis, to obtain indirect information on human exposure. Among others, the pilot project investigated the suitability of Italian rye-grass as a biological indicator for aluminium, arsenic, cadmium, cobalt, chromium, copper, iron, mercury, magnesium, manganese, nickel, lead, platinum, antimony, titanium, and zinc. (orig./GL).
British Library Electronic Table of Contents (United Kingdom)
The rate and intensity of land use land cover (LULC) change has increased considerably during the past couple of decades. Mining brings significant alterations in LULC specifically due to its impact on forests. Parts of Central India are well endowed with both forests and minerals. Here, the conflict between human interests and nature has intensified over time. Monitoring and assessment of such conflicts are important for land management and policy making. Remote sensing and Geographical Information System have the potential to serve as accurate tools for environmental monitoring. Understanding the importance of landscape metrics in land use planning is challenging but important. These metrics calculated at landscape, class, and patch level provide an insight into changing spatiotemporal d...
2010-01-01
Fundamental limits on beam stability at the advanced photon source
International Nuclear Information System (INIS)
Orbit correction is now routinely performed at the few-micron level in the Advanced Photon Source (APS) storage ring. Three diagnostics are presently in use to measure and control both AC and DC orbit motions: broad-band turn-by-turn rf beam position monitors (BPMs), narrow-band switched heterodyne receivers, and photoemission-style x-ray beam position monitors. Each type of diagnostic has its own set of systematic error effects that place limits on the ultimate pointing stability of x-ray beams supplied to users at the APS. Limiting sources of beam motion at present are magnet power supply noise, girder vibration, and thermal timescale vacuum chamber and girder motion. This paper will investigate the present limitations on orbit correction, and will delve into the upgrades necessary to achieve true sub-micron beam stability.
1998-12-10
Development of a through-the-earth monitor system. Open file report (final) Oct 77-Dec 80
Energy Technology Data Exchange (ETDEWEB)
The object of this program was to design and build a self-contained system for remote monitoring of the atmosphere in mines. The system developed uses the mine pager phone line as the primary communication channel and also has the capability of using 208 Hz in the ELF band for wireless transmission through the earth. The depth for through-the-earth transmission is expected to be about 80 to 90 meters in high conductivity soil and is limited by the noise level in the ELF band-pass filters. The underground components of the TEM System are energized by mine power through a battery charger-storage battery power supply. In the event of mine power failure the battery capacity is more than sufficient for 1 week's operation with interrogations every 4 hours.
1980-12-01
British Library Electronic Table of Contents (United Kingdom)
Nuclear magnetic resonance (NMR) techniques coupled with multivariate data analysis were used to conduct monitoring of biochemical changes of black raspberry fruits at different stages of maturation and under various extraction and NMR dissolution solvent conditions: extraction with 50% methanol and D"2O as an NMR dissolution solvent, extraction with 50% methanol and 50% methanol-d"4 as an NMR dissolution solvent, and extraction with 100% ethyl acetate and 100% methanol-d"4 as an NMR dissolution solvent. Partial least-squares discriminant analysis reliably distinguished black raspberry fruits according to the maturation stage, whereby the relative levels of various compounds such as amino acids, organic acids, sugars and phenolic compounds were compared using analysis of variance. Sucrose ...
2011-01-01
Absorption of carbon dioxide in waste tanks
International Nuclear Information System (INIS)
Air flow rates and carbon dioxide concentrations of air entering and exiting eight H-Area waste tanks were monitored for a period of one year. The average instanteous concentration of carbon dioxide in air is within the range reported offsite, and therefore is not affect by operation of the coal-fired power plant adjacent to the tank farm. Waste solutions in each of the tanks were observed to be continuously absorbing carbon dioxide. The rate of absorption of carbon dioxide decreased linearly with the pH of the solution. Personnel exposure associated with the routine sampling and analysis of radioactive wastes stored at SRP to determine the levels of corrosion inhibitors in solution could be reduced by monitoring the absorption of carbon dioxide and using the relationship between pH and carbon dioxide absorption to determine the free hydroxide concentration in solution.
1987-09-01
Energy Technology Data Exchange (ETDEWEB)
The causes and processes of contamination, as well as the possible human health implications for the main contaminants of drinking water are described. The quality of drinking water in Italy is defined through the comparison of the pollutant levels with the World Health Organization guidelines published in 1993 and the USEPA HAs (Health Advisories) of 1994 (annexed to the report).
1995-09-01
British Library Electronic Table of Contents (United Kingdom)
Sustainability of irrigated agriculture in arid and semi arid lands depends, mainly on the level of soil salinity and the quality of irrigation water. Remotely sensed data can provide information about the extent of vegetated irrigated areas. Al-Hassa oasis, Saudi Arabia is probably the largest oasis in the world depends mostly on tapped ground water to irrigate mainly date palm groves for its economic survival. This study tried to investigate the extent of soil salinity and the quality of irrigation water and the relationship with vegetation growth, employing NDVI derived from Landsat satellite imagery.
2011-01-01
An assessment of the building sector efficiency resource for the Town of Handlova
Energy Technology Data Exchange (ETDEWEB)
Purpose of this assessment for this town in the Slovak Republic is to develop information on the building sector energy efficiency and improvement potential for use by town management to support decisions on providing energy services to Handlova citizens. Objectives were to characterize baseline space and water heat energy use and efficiency improvement potential in the residential and nonresidential building sectors. Intention was to identify major areas of efficiency improvement potential and cost-effectiveness. Four levels of energy and fuel prices were used. A significant efficiency resource exists in the space and water heating end uses in these building sectors; it amounts to 42% of the total building sector space and water heat energy consumption.
1995-10-01
A.C.R.O. activity report 2002; A.C.R.O. rapport d'activite 2002
Energy Technology Data Exchange (ETDEWEB)
A.C.R.O. (Association pour le Controle de la Radioactivite dans l Ouest) is a French non governmental organisation that operates a laboratory for radioactivity analysis. It was created in 1986 as a response to people demands for information and reliable, independent testing. The organisation mainly carries out missions of information and training for its correspondents and more generally for a wide audience, particularly for people who worry about problems of environment, health, management of radioactive waste and emissions. Thanks to its structure, it enables citizens to involve themselves together with scientists so as to gain access to information that was hither to reserved to specialists. The organisation can vouchsafe its independence from the diversity of its members and volunteers, as well as from the diversity of its money resources. Besides its headquarters situated on the city of Caen area (Normandy), three branches situated in North Normandy, in Touraine and North Cotentin ...
2002-07-01
Human exposure to PCDDs, PCDFs, and dioxin like PCBs in Japan, 2001
Energy Technology Data Exchange (ETDEWEB)
In our previous study, we have estimated the level of human exposure to dioxins (PCDDs, PCDFs, and Dioxin like PCBs) in Japan based on dioxins monitoring data and results of total diet studies (TDS) in fiscal 2000 (April 2000- March 2001). It has been reported that the national PCDDs/DFs emission in 2001 against the 1997 level has been reduced by approximately 77% In addition, reduction of environmental levels was reported. The enforcement of Japan's Law Concerning Special Measures against Dioxins has significant impact on the reduction of the average dioxins concentrations in the ambient air. Therefore, the transitions of Japanese dioxins exposure levels in recent years are worthy of attention. In order to determine exposure level in fiscal 2001, collection and compilation for surveillance results derived from the regular environmental ...
2004-09-15
The Oak Ridge Y-12 Plant biological monitoring and abatement program for East Fork Poplar Creek
Energy Technology Data Exchange (ETDEWEB)
In May 1985, a National Pollutant Discharge Elimination System permit was issued for the Oak Ridge Y-12 Plant, a nuclear weapons components production facility located in Oak Ridge, Tennessee, and operated by Martin Marietta Energy Systems, Inc., for the US Department of Energy. As a condition of the permit, a Biological Monitoring and Abatement Program (BMAP) was developed to demonstrate that the effluent limitations established for the Oak Ridge Y-12 Plant protect the classified uses of the receiving stream (East Fork Poplar Creek), in particular, the growth and propagation of fish and aquatic life, as designated by the Tennessee Department of Health and Environment. A second purpose for the BMAP is to document the ecological effects resulting from implementation of a water pollution control program that will include construction of nine new wastewater treatment facilities over the next 4 years. Because of the complex nature of the effluent ...
1989-10-01
Energy Technology Data Exchange (ETDEWEB)
The success in developing of the oil industry operating in offshore-onshore terminals, connected by pipelines with the facilities of the coastal zone, can be attributed partially to the beach morpho dynamic monitoring. This study represents a solution to the concerns of the technical operations in coastal zones because it minimizes the impact of the petroleum production and it assures the environmental protection associated to the risks of the pipelines breaking. This impact type results mainly of the vertical and horizontal displacements of the beach, from the coastal dunes to the shore face. The mobility of the profile is associated to the magnitude of the sedimentary processes, which reproduce naturally or not, in scale of time that can vary among few days, years or decades. For the monitoring and interpretation of the beach profile mobility the following methods are recommended: calculation of the closure depth with base in the wave data; ...
2003-07-01
Design of the electromagnetic fluctuations diagnostic for MFTF-B
Energy Technology Data Exchange (ETDEWEB)
The Electromagnetic Fluctuations (EMF) diagnostic will be used to monitor ion fluctuations which could be unstable in MFTF-B. Each probe assembly includes a high impedance electrostatic probe to measure potential fluctuations, and a group of nested, single turn loops to measure magnetic fluctuations in three directions. Eventually, more probes and loops will be added to each probe assembly for making more detailed measurements. The sensors must lie physically close to the plasma edge and are radially positionable. Also, probes at separate axial locations can be positioned to connect along the same magnetic field line. These probes are similar in concept to the rf probes used on TMX, but the high thermal load for 30-second shots on MFTF-B requires a water-cooled design along with temperature monitors. Each signal channel has a bandwidth of .001 to 150 MHz and is monitored by up to four different data ...
1983-11-28
2008 Data Report: Groundwater Monitoring Program Area 5 Radioactive Waste Management Site
This report is a compilation of the groundwater sampling results from the Area 5 Radioactive Waste Management Site (RWMS) including calendar year 2008 results. Each of the three Pilot Wells was sampled on March 11, 2008, and September 10, 2008. These wells were sampled for the following indicators of contamination: pH, specific conductance, total organic carbon, total organic halides, and tritium. Indicators of general water chemistry (cations and anions) were also monitored. Results from all samples collected in 2008 were within the limits established by agreement with the Nevada Division of Environmental Protection for each analyte. These data indicate that there has been no measurable impact to the uppermost aquifer from the Area 5 RWMS. There were no significant changes in measured groundwater parameters compared to previous years. Other information in the report includes an updated Cumulative Chronology for the Area 5 RWMS Groundwater ...
2009-01-13
2006 Data Report: Groundwater Monitoring Program Area 5 Radioactive Waste Management Site
This report is a compilation of the groundwater sampling results from the Area 5 Radioactive Waste Management Site (RWMS) for calendar year 2006. Pilot wells UE5PW-1, UE5PW-2, and UE5PW-3 were sampled in April and October 2006 for the following indicators of contamination: pH, specific conductance, total organic carbon, total organic halides, and tritium. Indicators of general water chemistry (cations and anions) were also monitored. Results from all samples collected in 2006 were within the limits established by agreement with the Nevada Division of Environmental Protection for each analyte. These data indicate that there has been no measurable impact to the uppermost aquifer from the Area 5 RWMS. There were no significant changes in measured groundwater parameters compared to previous years. Other information in the report includes an updated Cumulative Chronology for the Area 5 RWMS Groundwater Monitoring Program and a ...
2007-02-01
International Nuclear Information System (INIS)
In the case of a release of residual power and fragmenting following a hypothetical accident the applied powers are small. The boiling in the fluid in the bed promotes leveling and the angles of repose obtained are very small. For a specific power in water of 3.1 W/cm_3 a limiting angle of repose of less than 2 degrees is obtained after a time interval of between 1 and 3 hours. EDULCOREE-and ETABUL-research programs are carried out. (DG).
Characterisation of long-lived low and intermediate-level radioactive wastes in the Nordic Countries
International Nuclear Information System (INIS)
The present report is final report from a study on characterisation of radioactive waters in the Nordic countries. The study has mainly been focused on long-lived low and intermediate level radioactive waste. Methods to measure or estimate the activity content and the general composition are discussed. Recommendations are given regarding characterisation of waste under treatment and characterisation of already produced waste packages. (au).
2005-01-01
British Library Electronic Table of Contents (United Kingdom)
In this study two surface sensitive methods, i.e. quartz crystal microbalance with dissipation monitoring (QCM-D) and ellipsometry, were used for erosion measurements of a rosin-based marine antifouling paint binder. Thin films of the binder were applied on sensor surfaces by the means of spin-coating and the effect of water velocity over the paint film, water temperature or ionic strength on erosion was investigated. Both the acoustic QCM-D model and the optical ellipsometry model gave comparable erosion results. The initial 2-50nm rapid erosion of the top layer was followed by steady-state erosion rate until end of experiment. For example, the steady-state erosion rate was 12nm/24h in artificial seawater at 23degreeC and with a flow of 200ml/min over the paint surface as measured with QC...
2008-01-01
Effective multiplication factor measurement by feynman-{alpha} method. 3
Energy Technology Data Exchange (ETDEWEB)
The sub-criticality monitoring system has been developed for criticality safety control in nuclear fuel handling plants. In the past experiments performed with the Deuterium Critical Assembly (DCA), it was confirmed that the detection of sub-criticality was possible to k{sub eff} = 0.3. To investigate the applicability of the method to more generalized system, experiments were performed in the light-water-moderated system of the modified DCA core. From these experiments, it was confirmed that the prompt decay constant ({alpha}), which was a index of the sub-criticality, was detected between k{sub eff} = 0.623 and k{sub eff} = 0.870 and the difference of 0.05 - 0.1{Delta}k could be distinguished. The {alpha} values were numerically calculated with 2D transport code TWODANT and monte carlo code KENO V.a, and the results were compared with the measured values. The differences between calculated and measured values were proved to be less than 13%, ...
1998-06-01
Conceptual fusion power monitor based on the "1"6O(n,p)"1"6N reaction
International Nuclear Information System (INIS)
The feasibility of developing a fusion power monitor based on a fluid activation detector is considered here. The activation fluid may be either a liquid or a gas and its composition can be selected from a number of candidate materials to provide desired activation and decay characterisitcs. Performance calculations indicate that ordinary water would be a nearly ideal activation fluid. The "1"6O(n,p)"1"6N reaction has a threshold at about 10 MeV and a cross section energy dependence giving it a predominant response for unmoderated D-T fusion neutrons. Adequate activation can be obtained at moderate flow rates for remote counting away from the high radiation area of the reactor. The 7.16 sec half-life of "1"6N is ideal for remote counting with subsequent decay in a small hold-up tank to eliminate activity build-up in the recycled water.
1981-07-01
International Nuclear Information System (INIS)
Through the analysis of the relations between "3H monitoring results of sea water in West Daya Bay carried out by Guangdong Environmental Radiation Research and Monitoring Center (GERC) from 1994 to 2000 and the quantity of liquid "3H discharges made by Guangdong Nuclear Power Station (GNPS), the function has been found by fitting to describe the relation between "3H average concentrations (hereafter as to average concentration or concentration) for all sampling points at the same time and the quantity of liquid "3H discharges. "3H instantaneous concentrations or yearly average concentration in West Daya Bay can be estimated conveniently by using this function corresponding to either actual discharges or supposed discharges (the way for hydrodynamic calculation) from the GNPS's yearly "3H liquid discharge. The results have shown that the general influences both actual discharges and supposed sub-continuous discharges are ...
2001-11-01
4D experience on Girassol Field block 17, Angola
Energy Technology Data Exchange (ETDEWEB)
The Girassol field is located in Angolan deep water of Block 17 and consists of large vertically stacked turbidities complexes. The reservoir extends over approximately 200 km{sup 2} and water depth ranges between 1300 and 1400 meters. In that context High Resolution 3D seismic became the most valuable tool to describe and monitor the reservoir. The field development plan took into account, through re-injection of the gas into the reservoir, Total environmental policy imposing the recycling of production gas. Monitoring of this injection was the main reason to shoot the first High Resolution 4D extremely early in the life of field. Despite the complexity of interpretation due to complex fluid situation and pressure effect, the results went way beyond expectations as the 4D images are of very high quality. Data has also been used to update and refine the reservoir flow model as well as to help deciding ...
2004-07-01
Effects of pork/beef levels and various casings on quality properties of semi-dried jerky
British Library Electronic Table of Contents (United Kingdom)
The aim of this study was to investigate the effects of pork/beef levels and the casings on the quality properties of semi-dried jerky. The pork/beef levels in the four test formulations were as follows: T-1 (pork: beef=100:0), T-2 (95:5), T-3 (90:10), and T-4 (80:20). After tumbling for 30min with curing solution, the cured meats were stuffed into natural sheep casings, collagen casings, or cellulose casings, and then dried. The restructured jerky with cellulose casing had the lowest water content and the highest protein content, with no significant differences between various formulations. There were no significant differences among all formulations with regard to pH and total microbial counts, and jerky with cellulose casing had the lowest value of water activity. The processing yields ...
2008-01-01
CFD Approaches for Modelling Bubble Entrainment by an Impinging Jet
International Nuclear Information System (INIS)
This contribution presents different approaches for the modeling of gas entrainment under water by a plunging jet. Since the generation of bubbles happens on a scale which is smaller than the bubbles, this process cannot be resolved in meso-scale simulations, which include the full length of the jet and its environment. This is why the gas entrainment has to be modeled in meso-scale simulations. In the frame of a Euler-Euler simulation, the local morphology of the phases has to be considered in the drag model. For example, the gas is a continuous phase above the water level but bubbly below the water level. Various drag models are tested and their influence on the gas void fraction below the water level is discussed. The algebraic interface area density (AIAD) model applies a drag coefficient for bubbles and a different drag coefficient for ...
5101-01-01
Using long term biological monitoring data to evaluate the recovery of disturbed systems
International Nuclear Information System (INIS)
Biological monitoring has been conducted in industrially impacted streams near US Department of Energy facilities in Tennessee and Kentucky for almost ten years. A comprehensive Biological Monitoring and Abatement Program, which was developed to meet National Pollutant Discharge Elimination System permit requirements, includes tasks on (1 ) toxicity testing; (2) bioaccumulation in aquatic and terrestrial biota; (3) bioindicators of fish health; and (4) fish, macroinvertebrate, and periphyton community surveys. These studies have been used successfully to characterize spatial trends and demonstrate temporal recovery resulting from remedial actions and pollution abatement activities, identify contaminant sources, and provide data for conducting ecological risk assessments. The program uses multiple lines of evidence to evaluate stream recovery and illustrates the importance of using an integrated approach when determining stream health. An ...
1995-11-05
Truck tactics: dispatch from Vancouver
Energy Technology Data Exchange (ETDEWEB)
Any mine that uses haultrucks has a dispatching system of some sort, even if it is only a very basic and simple arrangement. The larger, more complex operations have found that, if properly applied, automated computerised dispatching improves the productivity of the equipment as well as improving overall control and reporting. However, not every mine can justify going this far; in these cases a computerised monitoring and reporting system with manual dispatching can still give considerable benefits. Wenco International Mining Systems of Vancouver supplies its computerised system to three different specification levels to suit most open pit mining operations. The article describes the 3 PMCSs (Production Monitoring and Control System) available: PMCS 1000, for monitoring and reporting only; PMCS 2000, for dispatching to maximise production; and PMCS 3000, for dispatching with optimised product quality ...
1991-11-01
The influence of salt aerosol on alpha radiation detection by WIPP continuous air monitors
Energy Technology Data Exchange (ETDEWEB)
Alpha continuous air monitors (CAMs) will be used at the Waste Isolation Pilot Plant (WIPP) to measure airborne transuranic radioactivity that might be present in air exhaust or in work-place areas. WIPP CAMs are important to health and safety because they are used to alert workers to airborne radioactivity, to actuate air-effluent filtration systems, and to detect airborne radioactivity so that the radioactivity can be confined in a limited area. In 1993, the Environmental Evaluation Group (EEG) reported that CAM operational performance was affected by salt aerosol, and subsequently, the WIPP CAM design and usage were modified. In this report, operational data and current theories on aerosol collection were reviewed to determine CAM quantitative performance limitations. Since 1993, the overall CAM performance appears to have improved, but anomalous alpha spectra are present when sampling-filter salt deposits are at normal to high levels. This ...
1996-01-01
Energy Technology Data Exchange (ETDEWEB)
This paper reports on the generator condition monitor (GCM) developed in an attempt to detect overheating inside large turbine generators. As part of a broader study on rotating machinery diagnostics, generator condition monitors were evaluated under field conditions in a 550 MW turbogenerator. Small 100 W resistors coated with insulating paints and varnishes were mounted inside the generator to simulate insulation overheating. The GCM responded very rapidly to an overheating event, typically within two minutes, even for hot spots as small s 10 cm{sup 2}. Similarly the aerosols produced on overheating were found extremely short lived, decaying within two to three minutes after overheating was discontinued. Use of heated ion chambers was found to desensitize the GCM regardless of the nature of the overheated insulation and in some cases would altogether prevent the GCM from reaching the 50% pre-set alarm level commonly used ...
1990-06-01
Energy Technology Data Exchange (ETDEWEB)
Three test instruments are being evaluated to determine the feasibility of using photoacoustic technology for measuring unburned carbon in fly ash. The first test instrument is a single microwave frequency system previously constructed to measure photoacoustic signals in an off-line configuration. A second off-line instrument was constructed based in part on lessons learned with the first instrument, but which also expands the capabilities of the first instrument. Improvements include a control loop to allow more constant microwave power output and an ability to operate over a range of microwave frequencies. The third instrument, the on-line version of the fly ash monitor, has been designed, constructed, and initial efficiency tests have been conducted on the monitor's electrical components. This quarter focused on improving the signal strength of the accelerometer by increasing the power level of the microwaves ...
2004-07-01
Noninvasive analysis of skin iron and zinc levels in beta-thalassemia major and intermedia
Energy Technology Data Exchange (ETDEWEB)
Diagnostic x-ray spectrometry, a method based on x-ray fluorescence analysis, was used for noninvasive determination of iron and zinc in two distinct skin areas, representing predominantly dermal and epidermal tissues, in 56 patients with beta-thalassemia major and intermedia. The mean iron levels in the skin of patients with beta-thalassemia major and intermedia were elevated by greater than 200% and greater than 50%, respectively, compared with control values. The zinc levels of both skin areas examined were within the normal range. The data indicate that the rate and number of blood transfusions, which correlated well with serum ferritin levels (r . 0.8), are not the only factors that determine the amount of iron deposition in the skin (r less than 0.6). Other sources of iron intake contribute to the total iron load in the tissues, particularly in patients who are not given multiple transfusions. The noninvasive ...
1985-01-01
Computer programs have been developed to define the temperature increase which would be needed to bring deep-ocean water into density equilibrium with surface water for locations where data are available. A series of continuous-flow studies on phytoplankton blooms resulting from mixtures of 80 percent deep and 20 percent surface water in 2000-liter concrete culturing vessels (''reactors'') has been completed. A quantitative determination of nutrient utilization and flow through a combined primary and secondary trophic level system has been completed. This study utilized the clam Tapes semidecussata, fed from phytoplankton grown in 80 percent deep and 20 percent surface water. An analysis of the fate of the deep water discharged from a floating OTEC plant indicates that horizontal containment of the resulting deep ...
1976-01-01
Energy Technology Data Exchange (ETDEWEB)
The theme of the conference was recent developments in airborne remote sensing and their applications. The proceedings contain the papers presented at 14 general sessions and 13 interactive sessions covering airborne platforms, sensor systems, airborne/spaceborne synergy, atmospheric and oceanic measurements, land cover/land use, emergency response and reconnaissance, data handling, forestry, agriculture, water resources, geospatial reference, system calibration, environmental monitoring and planning, and information product advancements. Two papers are abstracted separately.
1999-07-01
Oil shale oxidation at subretorting temperatures
Energy Technology Data Exchange (ETDEWEB)
Green River oil shale was air oxidized at subretorting temperatures. Off gases consisting of nitrogen, oxygen, carbon monoxide, carbon dioxide, and water were monitored and quantitatively determined. A mathematical model of the oxidation reactions based on a shrinking core model has been developed. This model incorporates the chemical reaction of oxygen and the organic material in the oil shale as well as the diffusivity of the oxygen into the shale particle. Diffusivity appears to be rate limiting for the oxidation. Arrhenius type equations, which include a term for oil shale grade, have been derived for both the chemical reaction and the diffusivity.
1980-06-01
Corrosion 2003. Conference papers on CD-ROM
Energy Technology Data Exchange (ETDEWEB)
Papers are presented under 38 symposia. Subjects included reinforced concrete, protective coatings and linings, cathodic/anodic protection, chemical cleaning of boilers, managing corrosion with plastics, water treatment, HRSG boiler tube failure analysis, corrosion in oil and gas production, corrosion in petroleum refining and gas, processing, pipelines and tanks, high temperature materials, chemical process industry, aerospace equipment, materials technology developments for incinerators and waste fuel-fired processors, materials and corrosion in fossil-fuels conversion and combustion, corrosion in nuclear systems, marine corrosion, building systems, corrosion mechanisms, corrosion inhibitors and corrosion monitoring and measurement.
2003-07-01
Application of the neutron television fluoroscopic system to neutron computed tomography
Energy Technology Data Exchange (ETDEWEB)
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).
1984-10-01
Application of the neutron television fluoroscopic system to neutron computed tomography
Energy Technology Data Exchange (ETDEWEB)
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter.
1984-10-01
Annual Report 2007. Nuclear Regulatory Authority
International Nuclear Information System (INIS)
The present Annual Report of Activities of the Nuclear Regulatory Authority (ARN), prepared regularly from the creation as independent institution, describes across tree parts and seven annexes the activities developed by the organism during 2007. The main topic are: the organization and the activity of the ARN; the regulatory standards; the licensing and inspection of nuclear power plants and critical facilities; the emergency systems; the occupational surveillance; the environmental monitoring; improved organizational. Also, this publication have annexes with the following content: regulatory documents; inspections to medical, industrial and training installations; regulatory guides; measurement and evaluation of the drinking water of Ezeiza.
2004-07-11
An application of the neutron television fluoroscopic system to neutron computed tomography
International Nuclear Information System (INIS)
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).
1984-10-01
A general regression artificial neural network for two-phase flow regime identification
Energy Technology Data Exchange (ETDEWEB)
Supplementing the collection of artificial neural network methodologies devised for monitoring energy producing installations, a general regression artificial neural network is proposed for the identification of the two-phase flow that occurs in the coolant channels of boiling water reactors. The utilization of a limited number of image features derived from radiography images affords the proposed approach with efficiency and non-invasiveness. Additionally, the application of counter-clustering to the input patterns prior to training accomplishes an 80% reduction in network size as well as in training and test time. Cross-validation tests confirm accurate on-line flow regime identification.
2010-05-15
A general regression artificial neural network for two-phase flow regime identification
International Nuclear Information System (INIS)
Supplementing the collection of artificial neural network methodologies devised for monitoring energy producing installations, a general regression artificial neural network is proposed for the identification of the two-phase flow that occurs in the coolant channels of boiling water reactors. The utilization of a limited number of image features derived from radiography images affords the proposed approach with efficiency and non-invasiveness. Additionally, the application of counter-clustering to the input patterns prior to training accomplishes an 80% reduction in network size as well as in training and test time. Cross-validation tests confirm accurate on-line flow regime identification.
2010-05-01
Liquid zone system events at Wolsong Unit 2
International Nuclear Information System (INIS)
On June 19, 1998, after the first annual outage, Wolsung Unit 2 was shutdown at a controlled rate due to the continuous instability of Liquid Zone Control level. Investigation revealed that the Liquid Zone Control level instability was caused by water condensed inside the helium lines, generated from the moistened helium flow, especially, inside the helium balance header feed and bleed valve lines. It was found that improper installation of the diaphragm type isolation valves and the drain valve tap could easily contain the water inside the lines and be destined to form water traps causing the balance header pressure oscillation. After the lines were dried, Liquid Zone Control level instability was almost vanished, and approached the allowable equilibrium state. As the reactor power was increased, however, the zone level instability ...
1998-09-07
Interfaces in aquatic ecosystems: Implications for transport and impact of anthropogenic compounds
Energy Technology Data Exchange (ETDEWEB)
Mechanisms that govern transport, accumulation and toxicity of persistent pollutants at interfaces in aquatic ecosystems were the foci of this thesis. Specific attention was paid to humic substances, their occurrence, composition, and role in exchange processes across interfaces. It was concluded that: The composition of humic substances in aquatic surface microlayers is different from that of the subsurface water and terrestrial humic matter. Levels of dissolved organic carbon (DOC) in the aquatic surface microlayer reflect the DOC levels in the subsurface water. While the levels and enrichment of DOC in the microlayer generally show small variations, the levels and enrichment of particulate organic carbon (POC) vary to a great extent. Similarities exist between aquatic surface films, artificial semi-permeable and biological membranes regarding their structure ...
1996-11-01
Behavior of ice covers subjected to large daily flow and level fluctuations
Energy Technology Data Exchange (ETDEWEB)
The stability of a solid ice cover subjected to rapidly varying water levels and discharge was investigated. The support from the bank limits the stress in the ice cover and consequently bank contact must be maintained to ensure ice cover stability. An analysis was required of the stability of ice hinges, a flexible connection between a solid ice cover and the riverbank. Phase II and phase III of the research involved a field study of the Peace River, investigating the evolution of ice hinges with water level variation, from initial ice cover cracking parallel to the banks, to a fully developed hinge. A test program of midwinter discharge variations was undertaken to gather specific data and measurements of ice hinge link length, ice thickness, hinge joint behavior, riverbank geometry, and response of ice hinging to water level variation. As a result of the ...
1984-11-01
Deployment Support Leading to Implementation
Energy Technology Data Exchange (ETDEWEB)
The following paragraphs summarize the progress of each research project funded under the WVU Cooperative Agreement during the third quarter of 1997 (July - September 1997). The projects are arranged according to their 1997 WVU task number. WVU Focus Area 1.0: Subsurface Contaminants, Containment and Remediation Task No. 1.1: Project discontinued. Task No. 1.2: Development of Standard Test Protocols and Barrier Design Models for Desiccation Barriers (K. Amininan & S. Ameri): A number of experiments were preformed this period to evaluate the ability of the dried sand-packs to act as a barrier to liquids. Water infiltration tests were done with a constant head, dispersing 80 ml of water, and by adding water in small increments. Results indicate that when the water is spilled over the sand-pack, it has the tendency to channel through the sand-pack, significantly reducing the capacity of the dried zone ...
1997-10-01
Remote sensing analysis of rainstorm effects on sediment concentrations in Apalachicola Bay, USA
British Library Electronic Table of Contents (United Kingdom)
Remote sensing of total suspended solids (TSS) by satellite techniques in estuaries and bays plays an important role in monitoring water quality over a large area. It is valuable to the management of coastal water environment and ecosystems. In this study, remote sensing mapping of TSS was conducted to investigate the effects of rainstorm events on Apalachicola Bay. A rainstorm event (October 7-8, 2008) was selected for a period when wind speeds were weak and the river inflow was almost steady. TSS mapping of MODIS images before and after the rainstorm event showed substantial increase of TSS induced by the rainstorm. Using an image during low river discharge before the rainstorm as a reference, TSS distribution was mapped by an improved regression model using MODIS image after a rainstorm...
2011-01-01
Monitoring transplanting operation of rice crop using passive microwave radiometer data
British Library Electronic Table of Contents (United Kingdom)
This study highlights a methodology to detect the transplanting operation of wetland rice at a regional scale using SSM/I brightness temperature in frequencies like 19, 37 and 85 GHz with vertical polarization. A cloud removal algorithm was used to make weekly composites of the brightness temperature, which were used to estimate the soil wetness index (SWI). Flooding of rice fields with water for transplanting induces very high change in SWI due to contrasting dielectric constant of water (80) and soil (4). Different weather conditions and fractional wet area under the footprint of sensor affect SWI, hence absolute value of SWI was not adequate. Therefore, multi-year SWI anomaly was used to generate a threshold value of SWI change to detect when SWI change between two consecutive weeks was...
2011-01-01
Influence of recycling and temperature on the swelling ability of paper
British Library Electronic Table of Contents (United Kingdom)
Hornification is the loss of fiber wall swelling which is detrimental to subsequent recycling resulting from drying. It is known that dried fibers lose their conformability and swelling capacity. The effect of recycling treatment on the swelling ability of hardwood bleached kraft pulp fibers was determined. Modelling paper recycling, sheets were recycled using heat treatment (23?C, 60?C, 100?C). The results were compared with those for natural fibers from bleached kraft pulp. Swelling kinetics of sheets was measured by a modified method monitoring interactions of pulp with water. Swelling ability decreased during the recycling in comparison with never-recycled pulp at all temperatures. Recycling of sheets caused only small changes in the cupri-ethylene-diamine viscosity, however, the water...
2011-01-01
Geochemical modelling of acidification and recovery in forest soils and runoff waters
Energy Technology Data Exchange (ETDEWEB)
The Model of Acidification of Groundwaters in Catchments (MAGIC) was used to simulate the impact of acidifying deposition and future recovery at the Gaardsjoen Covered Catchment Experiment, at a number of hypothetical stations defined by statistical variation of the Gaardsjoen data and at 20 forest monitoring sites in Southern Sweden. For the future predictions a decrease of sulphur deposition of more than 70% was assumed. This assumption is based on a full implementation of the agreements made under the second sulphur protocol from 1994. The modelled impact of reduced deposition on the soils and on the runoff waters was discussed. To complement the discussion on long-term trends in future run-off chemistry, data from Gaardsjoen has been used to asses the risk for short-term acid runoff episodes 26 refs, 23 figs, 7 tabs
1999-01-01
British Library Electronic Table of Contents (United Kingdom)
Purpose Nonpoint sources (NPS) pollution has been an important cause for water quality impairment worldwide. To take the temporal variations of both NPS pollution and in-stream attenuation into consideration, an inverse modeling approach and the load duration curve (LDC) method were combined for variable nutrient total maximum daily load (TMDL) development. Methods Water quality and hydrological parameters were monitored monthly along the ChangLe River system in 2004?2008. The catchment NPS export load (EL) and TMDL for total nitrogen (TN) were estimated by the inverse format of an existing stream nutrient transport equation. The LDC method was used to describe the variability of EL, TMDL, requiring load (RLR) and percent (the ratio between the RLR and the EL, RPR) reduction, and then to s...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
Coal mining activities cause an increased acidity and an associated decrease of the pH-value in mine waters. This process is also known as acid mine drainage (AMD). Due to AMD, lakes that were formed in the post mining landscapes in the lignite mining area of Central Germany are characterized by specific limnological development changes. Remote sensing is a time and cost saving technique that enables the observation of the hydrological and limnological development of the lakes ranging from a small to a mid size scale. The current research was based on Landsat TM5/ETM+7 satellite data collected between 1999 and 2004. In combination of satellite data, surface waters of the post mining lakes in Central Germany were sampled and analyzed for their physicochemical properties. The objective of th...
2011-01-01
International Nuclear Information System (INIS)
Liquid Zone Control (LZC) System is a 'first-of-its-kind' reactivity control device, designed and implemented at TAPP-3 and 4. The system provides zonal and bulk power control. The system consists of fourteen Zone Control Compartments (ZCCs) containing demineralised light water as neutron absorber. Reactivity control is achieved by varying the level of water in the compartments bi-directionally. Six in-core zircaloy assemblies, housing the fourteen ZCCs and an elaborate process system constitute the LZC system. Measurement of water levels in the ZCCs is done using helium bubbler method. Reliability of ZCC water level measurement is of paramount importance. Commissioning and operating the new system trouble free was a challenge, considering the complex nature of the system. While commissioning the system, level ...
2006-11-13
Energy Technology Data Exchange (ETDEWEB)
After confirming that residual chlorine in tap water, which is regarded as one of the major cause of pitting corrosion, can be decomposed/removed by the irradiation of UV light, effect of dechlorinated water obtained based on this principle on the prevention of pitting corrosion, generation and growth, of the copper tubing was investigated by a corrosion test simulated the actual system in high buildings. (1) Low pressure type mercury lamp easily decompose/remove the residual chlorine. (2) If the dechlorinated water is supplied from the initial stage of copper tube usage, potential of the copper tube remains at the level of 100 mV/SCE and the generation of pitting corrosion is not observed. (3) Even when pitting corrosion is already found, switching to dechlorinated water in the midway reduces the potential of the copper tube down to 50 - 70 mV level, at the ...
1988-03-25
British Library Electronic Table of Contents (United Kingdom)
Water and soil samples from the area were therefore analyzed for their lead and zinc content. Computation of pollution statuses of lead and zinc revealed topsoil lead geoaccumulation indices of ?0.143 and ?0.069 and zinc geoaccumulation indices of 1.168 and 0.713 for Ishiagu and Uburu respectively. The pollution indices were determined to be 0.499 and 0.3564 for soil in Ishiagu and Uburu respectively and also 5.11 and 2.42 for water in Ishiagu and Uburu communities respectively. Water/soil concentration ratio were found to be 0.0018 and 0.0014 for lead in Ishiagu and Uburu respectively. On the other hand, the water/soil concentration ratio for zinc was computed to be 0.001 and 0.0008 for Ishiagu and Uburu respectively. These results seem to suggest that the pollution of the environment by ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
Because of the chaotic nature of the corrosion process and the complexity of the electrochemical noise signals that are generated, there is no generally accepted method of measuring and interpreting these signals that allows the consistent detection and identification of sustained localized pitting (SLP) as compared to general corrosion. We have reexamined electrochemical noise analysis (ENA) of localized corrosion using different hardware, signal collection, and signal processing designs than those used in conventional ENA techniques. The new data acquisition system was designed to identify and monitor the progress of SLP by analyzing the power spectral density (PSD) of the trend of the corrosion current noise level (CNL) and potential noise level (PNL). Each CNL and PNL data point was calculated from the root-mean- square value of the ac components of current and potential fluctuation signals, which were measured ...
1999-01-13
Biology and Monitoring of Diamondback Terrapins in the Chesapeake Bay
... to maintaining healthy terrapin populations in the Chesapeake. Biology and Monitoring of Diamondback Terrapins in the Chesapeake ... ...
Supervision monitoring for radiation environment around Daya Bay and Lingao nuclear power stations
International Nuclear Information System (INIS)
This paper systematically introduces the supervision monitoring for radiation environment around the Guangdong Daya Bay and Ling Ao nuclear power station by the Guangdong Environmental Radiation Research and Monitoring Center. It includes the monitoring plan, methods, quality assurance, main results and conclusions. The results show that: (1) The gas discharge have not caused any detectable impacts to the terrestrial and atmospheric environment since their operation; (2) "1"1"0"mAg could only be detected in seawater in the West Daya Bay in 1995 and 1997 and in sediments in 1997. The maximum annual average in seawater was 3.1 Bq/m"3, annual average of "1"1"0"mAg in sediments was 1.0 Bq/kg(dry). But it was always detectable in pearl oyster, gulfweed and cuttlefish in the West Daya Bay. The "1"1"0"mAg concentrations in halobios were relatively higher in 1994, 1996 and 1997. The maximum concentrations in pearl oyster, gulfweed ...
2004-05-01
The in-flight wavelength calibration for the Ozone Monitoring Instrument is discussed. The observed variability in the wavelength scale is two orders of magnitude larger than caused by temperature changes in the instrument. These wavelength variations are the result of rapid changes in time in the radiance levels during an individual observation in the presence of clouds or snow and ice. We have developed a data processing method to account and correct for these changes. In February 2005 this correction was implemented in the official data processing stream. We explain in detail how and how accurately this method works. Before correction, the error in the wavelength scale can be as much as a few tenths of a pixel; after correction it is mostly less than 1/100th of a pixel, which is the required preflight accuracy. This means that higher-level products such as the total column amounts of ozone, NO2, and SO2 are not ...
2006-05-01
Front-End-Electronics Communication software for multiple detectors in the ALICE experiment
Energy Technology Data Exchange (ETDEWEB)
In the ALICE experiment at CERN, the Detector Control System (DCS) employs several interacting software components to accomplish its task of ensuring the correct operation and monitoring of the experiment. This paper describes the Front-End-Electronics Communication (FeeCommunication) software and its role within the DCS. The FeeCommunication software's central task is passing configuration and monitoring data between the top level DCS process control and the field devices of several detectors within ALICE. The lowest level of the FeeCommunication software runs on the DCS boards, specialized embedded systems which are in direct contact with the field devices and are physically located within the detector. The middle and upper layers run on standard PC hardware located in the counting room or other external locations. This paper focuses on the design and implementation of the FeeCommunication ...
2006-02-15
BEATRIX-II: In situ tritium test
Energy Technology Data Exchange (ETDEWEB)
The BEATRIX-II irradiation experiment is an in-situ tritium release experiment being carried out in the Fast Flux Test Facility (FFTF) reactor to evaluate the tritium release characteristics of fusion solid breeder materials. A sophisticated tritium gas handling system has been developed to continuously monitor the tritium recovery from the specimens and facilitate tritium removal from the experiment's sweep gas flow stream. The in-situ recovery experiment accommodates two different in-reactor specimen canisters with individual gas streams and temperature monitoring/control. Ionization chambers have been specifically designed to respond to the rapid changes in the tritium release rate at the anticipated tritium concentrations. Two ceramic electrolysis cells have proved effective in reducing the moisture in the gas streams to hydrogen/tritium. A tritium getter system, capable of reducing the tritium level by a ...
1990-01-01
Analysis of dose rate build-up in Tarapur Atomic Power Station unit-4
International Nuclear Information System (INIS)
Tarapur Atomic Power Station Unit-4 was made critical on 6th March 2005. Since radiation field builds up with the power level due to formation of fission products and activation products in different systems. Radiation dose rates were recorded from different areas using Area Radiation Monitors (ARMs) installed at different areas. These monitors are connected to Radiation Data Acquisition System (RADAS). The trend of radiation field build-up was also analyzed by making survey of different plant areas at various power levels and comparison was made with RADAS readings. The results obtained were compared with 220 MWe dose rates. This study discusses about the dose rates observed at accessible area, shut down accessible area and hotspots observed during the early stage of operation of the reactor. The attempt was also made to find the contributing factors of the high dose rates. It was found that the ...
2005-11-23
Energy Technology Data Exchange (ETDEWEB)
NO{sub x} compounds, specifically NO and NO{sub 2}, are pollutants and potent greenhouse gases. Compact and inexpensive NO{sub x} sensors are necessary in the next generation of diesel (CIDI) automobiles to meet government emission requirements and enable the more rapid introduction of more efficient, higher fuel economy CIDI vehicles. Because the need for a NO{sub x} sensor is recent and the performance requirements are extremely challenging, most are still in the development phase. Currently, there is only one type of NO{sub x} sensor that is sold commercially, and it seems unlikely to meet more stringent future emission requirements. Automotive exhaust sensor development has focused on solid-state electrochemical technology, which has proven to be robust for in-situ operation in harsh, high-temperature environments (e.g., the oxygen stoichiometric sensor). Solid-state sensors typically rely on yttria-stabilized zirconia (YSZ) as the oxygen-ion conducting electrolyte and then target ...
2010-11-01
Remote handling and robotics at the BNFL Sellafield reprocessing plant
International Nuclear Information System (INIS)
As a direct result of its interest in the use of robotics within active plants, British Nuclear Fuels Ltd. (BNFL) has adopted a positive attitude toward both national and European initiatives in this area. During the early operation of the Sellafield reprocessing plant, the process vessels and cell voids were monitored using simple pole and camera combinations. In 1985, BNFL embarked on the provision of a series of machines intended to satisfy the advancing needs for inspection while increasing the level of expertise within the company in this important area. DIMAN 1, DIMAN 2, RODMAN, REPMAN, and RAFFMAN remote handling and robotic machines are described.
1990-11-11
British Library Electronic Table of Contents (United Kingdom)
Fifty patients scheduled to undergo IVF received a standard anesthetic of fentanyl and propofol for induction, followed by propofol infusion, with Bispectral index values and modified Ramsey sedation scores recorded at 5-minute intervals for the duration of anesthesia care. Moderate sedation was found only transiently during the first 5-10 minutes of the oocyte retrieval, but thereafter the level of sedation increased, with deep sedation and general anesthesia measured in all patients as determined by both the Bispectral index scores and lack of response to painful stimulation.
2011-01-01
Interim explosives detection alternatives
Energy Technology Data Exchange (ETDEWEB)
There is a general concern with insiders smuggling bomb quantities of explosives into sensitive facilities such as nuclear facilities. At this time, there is no single explosives detection device that is suitable for monitoring personnel and their packages for explosives in an operational facility environment. However, there are techniques combining available commercial technologies with procedures and threat analysis that can significantly increase the insiders risk and reduce the population of adversaries. This paper describes the available applicable explosives detection technologies and discusses the techniques that could be implemented on an interim basis. It is important that these techniques be considered, so that some interim level of security against the explosives threat can be established until more sophisticated equipment that is under development becomes available.
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
Construction of high voltage transmission lines in a difficult hilly terrain within the limited time frame calls for the adoption of modern management tools for controlling the progress. The activity on node network system for such works, in which parallel and overlapping activities are involved is highly useful and is being used in Himachal Pradesh State Electricity Board. This network system has helped the Board to provide an effective and efficient mode of progress reporting at all levels of functioning. A remarkable example is the control of construction of 190 km - 200 kV dc transmission line within four years and six months.
1987-02-01
A comparison of seasonal radon concentration and weekly screening measurements
Energy Technology Data Exchange (ETDEWEB)
Short-term radon measurements were used to make a comparison between weekly screening tests and seasonal concentration. The screening measurements were made in an indoor environment over a period of one quarter during early summer and the results are compared with the measured average radon level over that period. In these experiments, the envelope-type and plastic bag monitors were used for screening and long term radon concentration measurements, respectively. The results show that one cannot achieve predicting the seasonal mean radon concentration based on weekly measurements better than 50% under the conditions reported. (author).
1993-12-31
A comparison of seasonal radon concentration and weekly screening measurements
International Nuclear Information System (INIS)
Short-term radon measurements were used to make a comparison between weekly screening tests and seasonal concentration. The screening measurements were made in an indoor environment over a period of one quarter during early summer and the results are compared with the measured average radon level over that period. In these experiments, the envelope-type and plastic bag monitors were used for screening and long term radon concentration measurements, respectively. The results show that one cannot achieve predicting the seasonal mean radon concentration based on weekly measurements better than 50% under the conditions reported. (author).
Energy Technology Data Exchange (ETDEWEB)
An estimate of the tritium dose to the public in the vicinity of the heavy water research reactor facility at AECL-Chalk River Laboratories, Ontario, Canada, has largely been accomplished from analyses on regularly-collected samples of air, precipitation, drinking water and foodstuffs (pasture, fruit, vegetables and milk) and environmental dose models. To increase the confidence with which public doses are calculated, tritium doses were estimated directly from the ratio of tritiated species in urine samples from members of the general public. Single cumulative 24 h urine samples from a few adults living in the vicinity of the heavy-water research reactor facility at Chalk River Laboratories, Canada were collected and analysed for tritiated water and organically bound tritium. The participants were from Ottawa (200 km east), Deep River (10 km west) and Chalk River Laboratories. Tritiated ...
2001-07-01
Efficient methodologies for sensitive HIV-1 RNA quantitation from plasma and vaginal secretions
British Library Electronic Table of Contents (United Kingdom)
Background: Quantifying HIV levels in mucosal secretions is essential to study compartmentalized expression of HIV and facilitate development of intervention strategies to prevent disease progression and transmission. Objectives: To develop a sensitive, reliable, and cost-effective technique to quantify HIV from blood and vaginal secretions that is compatible with efficient implementation in clinical research environments. Study design: A sensitive, reliable, internally-controlled real-time reverse transcriptase (RT) PCR assay, which uses the HIV-1 pol gene as a target (Hpol assay) was developed to quantify HIV levels in plasma and genital secretions, and compared to the widely used Roche Amplicor(TM) HIV-1 Monitor assay. In addition, a simplified method of sample collection and processing...
2009-01-01
International Nuclear Information System (INIS)
A high-average power (kW) infrared (IR) free-electron laser (FEL) is currently being commissioned for the Jefferson Laboratory FEL User Facility. The IR FEL is driven by a unique superconducting rf linac which is recirculated to recover electron beam power that is not radiated in the FEL. The design and installation of the vacuum system for the FEL involved particular attention to minimizing particulate contamination which could cause problems with the superconducting acceleration cavities and the high power FEL optics. Particulate contamination levels of all vacuum components were monitored during the cleaning process using laser scattering. Cleaning, transport, and installation procedures were developed to minimize the contamination of the complete system. We will summarize a data base we compiled of particulate contamination levels of the various components installed in the FEL vacuum system.
1999-03-01
Experimental and theoretical studies on humidification-dehumidification-desalination
Energy Technology Data Exchange (ETDEWEB)
The shortage of fresh water is increasing at alarming levels, even in temperate zones. Desalination of brackish and seawater is being considered as a solution to growing water demands. Seawater desalination can be accomplished through reverse osmosis, vapor compression, vapor absorption and thermally driven systems. The most suitable process for large-scale desalination plants is successive brine evaporation-condensation with intermediate heat recovery. However, higher process efficiency could be achieved. The use of low temperature heat sources in seawater desalination requires an efficient method of evaporation and condensation at relatively low vapor pressures. This could be achieved in a humidification-dehumidification process using circulated air to enhance evaporation of water. Simulation models, however, neglect either the heat of evaporation or the changes in air and water ...
2006-07-01
Challenges in environmental radiological surveillance around nuclear facilities
International Nuclear Information System (INIS)
To accomplish the environmental radiological surveillance need of India's ambitious nuclear power programme, Health Physics Division is infusing new technologies and improved analytical techniques for day to day measurements of various radionuclides in different environmental matrices. It is essential to have techniques for measuring the concentration of radionuclides just above the background level since the discharges from the nuclear facilities are very low i.e. in the range of 5-10% of the prescribed discharge limits by the regulatory bodies. In view of developing ultra-sensitive techniques, the aim of ongoing programmes of the division is to meet the challenges of measuring ultra trace level of radioactivity by adopting state of art new instrumentation and improved sample processing techniques. This will allow us to measure the lowest level of radioactivity (3H, 90Sr, 137Cs, 239+240Pu, etc.) in the environment and ...
2007-06-05
Energy Technology Data Exchange (ETDEWEB)
At Los Alamos National Laboratory (LANL), a recent effort in waste minimization has focused on scrap metal from radiological controlled areas (RCAs). In particular, scrap metal from RCAs needs to be dispositioned in a reasonable and cost effective manner. Recycling of DOE scrap metals from RCAs is currently under a self-imposed moratorium. Since recycling is not available and reuse is difficult, often metal waste from RCAs, which could otherwise be recycled, is disposed of as low-level waste. Estimates at LANL put the cost of low-level waste disposal at $550 to $4000 per cubic meter, depending on the type of waste and the disposal site. If the waste is mixed, the cost for treatment and disposal can be as high as $50,000 per cubic meter. Disposal of scrap metal as low-level waste uses up valuable space in the low-level waste disposal areas and requires transportation to the disposal site under Department ...
2002-01-01
Water management studies in PEM fuel cells, Part I: Fuel cell design and in situ water distributions
Energy Technology Data Exchange (ETDEWEB)
A proton exchange membrane fuel cell (PEMFC) must maintain a balance between the hydration level required for efficient proton transfer and excess liquid water that can impede the flow of gases to the electrodes where the reactions take place. Therefore, it is critically important to understand the two-phase flow of liquid water combined with either the hydrogen (anode) or air (cathode) streams. In this paper, we describe the design of an in situ test apparatus that enables investigation of two-phase channel flow within PEMFCs, including the flow of water from the porous gas diffusion layer (GDL) into the channel gas flows; the flow of water within the bipolar plate channels themselves; and the dynamics of flow through multiple channels connected to common manifolds which maintain a uniform pressure differential across all possible flow paths. These two-phase flow effects have been ...
2009-05-15
Energy Technology Data Exchange (ETDEWEB)
This report summarizes work performed by Argonne National Laboratory on fatigue and environmentally assisted cracking (EAC) in light water reactors from January 1997 to June 1997. Topics that have been investigated include (a) fatigue of carbon, low-alloy, and austenitic stainless steels (SSs) used in reactor piping and pressure vessels, (b) irradiation-assisted stress corrosion cracking of Types 304 and 304L SS, and (c) EAC of Alloys 600 and 690. Fatigue tests were conducted on ferritic and austenitic SSs in water that contained various concentrations of dissolved oxygen (DO) to determine whether a slow strain rate applied during various portions of a tensile-loading cycle is equally effective in decreasing fatigue life. Slow-strain-rate-tensile tests were conducted in simulated boiling water reactor (BWR) water at 288 C on SS specimens irradiated to a low fluence in the Halden reactor and the results ...
1998-04-01
Energy Technology Data Exchange (ETDEWEB)
As part of the demonstration testing of the Purge Water Management System (PWMS) technology at the Savannah River Site (SRS), four wells were equipped with PWMS units in 1997 and a series of sampling events were conducted at each during 1997-1998. Three of the wells were located in A/M Area while the fourth was located at the Old Radioactive Waste Burial Ground in the General Separations Area.The PWMS is a ''closed-loop'', non-contact, system used to collect and return purge water to the originating aquifer after a sampling event without having significantly altered the water quality. One of the primary concerns as to its applicability at SRS, and elsewhere, is whether the PWMS might resample groundwater that is returned to the aquifer during the previous sampling event. The purpose of the present investigation was to compare groundwater chemical analysis data collected at the four test ...
1999-04-27
Energy Technology Data Exchange (ETDEWEB)
The CASTOC project addresses environmentally assisted cracking (EAC) phenomena in low alloy steels used for pressure boundary components in both Western type boiling water reactors (BWR) and Russian type pressurised water reactors (VVER). It comprises the four work packages (WP): inter-laboratory comparison test (WP1); EAC behaviour under static load (WP2), EAC behaviour under cyclic load and load transients (WP3); evaluation of the results with regard to their relevance for components in practice (WP4). The use of sophisticated test facilities and measurement techniques for the on-line detection of crack advances have provided a more detailed understanding of the mechanisms of environmentally assisted cracking and provided quantitative data of crack growth rates as a function of loading events and time, respectively. The effect of several major parameters controlling EAC was investigated with particular emphasis on the transferability of the ...
2004-07-01
Use of Hanford waste water ponds by waterfowl
International Nuclear Information System (INIS)
Census and environmental surveillance information on waterfowl that use the Hanford Site 200 Area waste water ponds are described and evaluated. Physical features of the ponds are discussed in relation to their use and suitability for waterfowl. Seasonal distributions observed for the years 1971 through 1974 indicate that the highest use by waterfowl occurs during the spring and fall migratory periods. Base population estimates are 300 to 400 resident waterfowl with a few tens of pairs nesting during the summer. Environmental surveillance data on "1"3"7Cs in muscle tissue are presented for the years 1971 through 1977. Comparisons are made between Columbia River and waste water pond waterfowl, between waterfowl groups, and among ponds. Waterfowl collected from ponds frequently have easily detected levels of "1"3"7Cs in muscle tissue. However, those waterfowl collected from the Columbia River seldom show a "1"3"7Cs ...
1979-05-01
Carbon Bed Mercury Emissions Control For Mixed Waste Treatment
International Nuclear Information System (INIS)
Mercury has had various uses in nuclear fuel reprocessing and other nuclear processes, and so is often present in radioactive and mixed (both radioactive and hazardous according to the Resource Conservation and Recovery Act) wastes. Depending on regulatory requirements, the mercury in the off-gas must be controlled with sometimes very high efficiencies. Compliance to the Hazardous Waste Combustor (HWC) Maximum Achievable Control Technology (MACT) standards can require off-gas mercury removal efficiencies up to 99.999% for thermally treating some mixed waste streams. Several test programs have demonstrated this level of off-gas mercury control using fixed beds of granular sulfur-impregnated activated carbon. Other results of these tests include: (a) The depth of the mercury control mass transfer zone was less than 15-30 cm for the operating conditions of these tests, (b) MERSORB(reg_sign) carbon can sorb Hg up to 19 wt% of the carbon mass, and (c) the spent carbon ...
2010-11-01
Anticipated climate change impacts on flood characteristics : Moisie River application
International Nuclear Information System (INIS)
The issue of global warming was discussed with particular reference to the changes that may occur in the hydrological regime within the coming decades in response to predicted changes in climate. Flood events for the 2050 time horizon were investigated along with the consequences on water management and dam safety. Dams operated by Hydro-Quebec are used for flood control, water supply, recreational activities and hydroelectricity. As such, the electric utility relies on methods to evaluate the adaptability of current management plans to climate change. This paper presented the results of a study conducted at the Moisie River watershed, located in northern Quebec. The HSAMI hydrologic model was used to evaluate and compare the occurrences where stream flows and water levels exceed critical values in order to assess the effectiveness of management plans in both current and climate change scenarios. The ...
Energy Technology Data Exchange (ETDEWEB)
This decision document presents the selected remedial action for the Westerly Wetlands, Northerly Wetlands, and Tar Patch Area at the Burnt Fly Bog Superfund Site. It addresses contaminated soil present on the three remaining contaminated areas on the Site, including the Westerly Wetlands, Northerly Wetlands, and Tar Patch Area. The major components of the selected remedy include: Excavation and off-site disposal of contaminated soil from the Northerly Wetlands; Excavation and off-site disposal of contaminated soil from the Tar Patch Area; Backfilling the excavated area in the Northerly Wetland and reestablishing wetlands; Backfilling the excavated area in the Tar Patch Area and creating wetlands; Provision of additional security fencing around the Westerly Wetlands, and the recording of a Deed Notice for the Westerly Wetlands, Northerly Wetlands, and Tar Patch Area; Monitoring of surface water and sediment in the Westerly Wetlands, surface ...
1999-03-01
Environmental management plan for the Jhario coalfield - India
Energy Technology Data Exchange (ETDEWEB)
An Environmental Management Plan (EMP) for the Jharia Coalfield (JCF) was recently completed as part of a World Bank funded project. The JCF, 260 km west of Calcutta, comprises 450 km{sup 2}. Bharat Coking Coal Limited (BCCL) operates an area of 258 km{sup 2}. Coal mining has been conducted for more than 100 years. There are severe constraints to mining due to geology, coal fires and the large population. BCCL counterpart staff participated actively in all aspects of the work. Air and water are heavily polluted, however, mining operations contribute only to a limited extent to the total pollution. Water contamination is generally due to inadequate sewage treatment and discharge from non-mine facilities such as power plants. The large area disturbed by mining to date will increase, as open pit mining operations are expected to expand significantly. Reclamation to date is generally confined to planting of trees. Areas where cost effective ...
1997-12-31
International Nuclear Information System (INIS)
A study has been performed of the initial corrosion of support structure alloys in crevices of various geometries, when galvanically coupled to alloy 600. Corrosion rates were monitored continuously by measuring the galvanic current flowing in each couple, transduced by a zero impedance ammeter. Experiments were performed in a single-pass flowing electrolyte system, with AVT water pumped through alloy 600 tubing past the orifice of each crevice. Fourteen crevices were studied simultaneously in two parallel flow arms containing seven specimens each. The steady state AVT water pH/hydrazine/oxygen concentrations were controlled by microcomputer, allowing the effect of secondary water chemistry on the corrosion rate to be studied easily. Control of the crevice electrolyte composition was achieved by separately pumping electrolyte, at a low rate, directly into the crevices of the seven specimens in the lower ...
1985-03-01
Corrosion failure and its prevention in light water reactor power plants
Energy Technology Data Exchange (ETDEWEB)
During 17 years since the start of operation of the first commercial LWR in Japan, many LWRs have experienced various corrosion damages, but the causes of them were clarified, and the counter-measures were executed effectively in actual plants, as the results, the cause of corrosion damage decreased remarkably, and now, the high rate of operation has become to be maintained. In this paper, the major cases of corrosion damage experienced in LWRs in Japan and foreign countries, the causes of them and the countermeasures, the problems of hereafter and so on are described. The corrosion damage of metallic materials in the environment of LWRs occurs in the parts in contact with high temperature, high pressure water and steam, such as stainless steel piping in the primary cooling system of BWRs, and nickel alloy heating tubes of steam generators, carbon steel feed water piping and zirconium alloy fuel cladding tubes in PWRs. Recently, accompanying ...
1988-01-01
Corrosion failure and its prevention in light water reactor power plants
International Nuclear Information System (INIS)
During 17 years since the start of operation of the first commercial LWR in Japan, many LWRs have experienced various corrosion damages, but the causes of them were clarified, and the counter-measures were executed effectively in actual plants, as the results, the cause of corrosion damage decreased remarkably, and now, the high rate of operation has become to be maintained. In this paper, the major cases of corrosion damage experienced in LWRs in Japan and foreign countries, the causes of them and the countermeasures, the problems of hereafter and so on are described. The corrosion damage of metallic materials in the environment of LWRs occurs in the parts in contact with high temperature, high pressure water and steam, such as stainless steel piping in the primary cooling system of BWRs, and nickel alloy heating tubes of steam generators, carbon steel feed water piping and zirconium alloy fuel cladding tubes in PWRs. Recently, accompanying ...
Energy Technology Data Exchange (ETDEWEB)
During the early years of the INEL, the USGS conducted extensive studies (sitewide drilling program) of the geology and hydrology of the area collecting varied data over the years. The unsaturated zone has not received much attention until recently. The studies that have been done are a result of problems or concerns arising from liquid radioactive waste disposal. The TRA facility has the most information published about its waste disposal activities. The ICPP has less data about the unsaturated zone due to the fact that most waste water disposal has been to a well. Little is known about the effect of waste water disposal at the NRF on the unsaturated zone. Essentially no information was found about waste disposal activities at other facilities, primarily because there does not appear to be any reported problems associated with waste water disposal at these locations. The RWMC has received much attention in the last few ...
1992-01-01
Energy Technology Data Exchange (ETDEWEB)
During the early years of the INEL, the USGS conducted extensive studies (sitewide drilling program) of the geology and hydrology of the area collecting varied data over the years. The unsaturated zone has not received much attention until recently. The studies that have been done are a result of problems or concerns arising from liquid radioactive waste disposal. The TRA facility has the most information published about its waste disposal activities. The ICPP has less data about the unsaturated zone due to the fact that most waste water disposal has been to a well. Little is known about the effect of waste water disposal at the NRF on the unsaturated zone. Essentially no information was found about waste disposal activities at other facilities, primarily because there does not appear to be any reported problems associated with waste water disposal at these locations. The RWMC has received much attention in the last few ...
1992-12-31
Energy Technology Data Exchange (ETDEWEB)
Extra-fine powdered activated charcoal has been used as stationary phase (coating layer) in solid-phase microextraction (SPME). The efficiency and reliability of the prepared device have been investigated for the extraction of some volatile organic compounds such as benzene, toluene, ethylbenzene and xylene isomers (BTEX) from the headspace of water samples. Monitoring of the extracted compounds and further quantitative analysis of the real samples have been performed by capillary GC-FID. Effects of several factors such as temperature, addition of salt, and stirring speed on extraction efficiency and exposure time have been studied. Under optimum conditions, extraction recoveries for these compounds from 50 mL water were >95%. The calibration graphs were linear in the range 5 to 10{sup 4} pg mL{sup -1} and the detection limit for each BTEX compound was 1.5-2 pg mL{sup -1}. The results obtained by use of this porous layer ...
1997-12-31
Synopsis of moisture monitoring by neutron probe in the unsaturated zone at Area G
Energy Technology Data Exchange (ETDEWEB)
Moisture profiles from neutron probe data provide valuable information in site characterization and to supplement ground water monitoring efforts. The neutron probe precision error (reproducibility) is found to be about 0.2 vol% under in situ field conditions where the slope in moisture content with depth is varying slowly. This error is about 2 times larger near moisture spikes (e.g., at the vapor phase notch), due to the sensitivity of the probe response to vertical position errors on the order of 0.5 inches. Calibrations were performed to correct the downhole probe response to the volumetric moisture content determined on core samples. Calibration is sensitive to borehole diameter and casing type, requiring 3 separate calibration relations for the boreholes surveyed here. Power law fits were used for calibration in this study to assure moisture content results greater than zero. Findings in the boreholes reported here confirm the broad ...
1997-12-31
Archive monitoring of pollutants in the Dee River using SIMS analysis of mussels
International Nuclear Information System (INIS)
Full text: Mt Morgan was mined for copper and gold from 1882 to 1982 and subsequent tailings re-processing ceased in 1990. Direct and accidental deposition of tailings into the adjacent Dee River and acid mine drainage from the mine site continues to impact the Dee River. The Queensland Department of Natural Resources gauging and monitoring station at Kenbula (adjacent to the mine) continuously monitors pH of around 2.8. Twenty kilometres downstream of the mine the pH improves to 3.5. Elevated sediment metal concentrations have been recorded over 50 kilometres downstream in investigations conducted by CSIRO (Jones et al. 1995, 1996) and others. Biological monitoring by Mackey (1988) and subsequently by Duivendoorden (1995,1997), confirmed significant impact on the fish, macrophyte of macro invertebrate populations downstream of the mine. The current AINSE sponsored project will investigate the use of mussels (genus ...
2000-11-29
Studies on the CRUD Deposition on Fuel Cladding Surface Using AOA Water Chemistry Loop
International Nuclear Information System (INIS)
Axial offset anomaly (AOA) is caused by the deposition of crud on the fuel cladding of a PWR. When significant levels of crud build up on the cladding, boron can accumulate in the pores of the crud as a concentrated solution or solid phase, and cause the flux depression. Numerous studies have been conducted on the primary water chemistry to reduce the amount of crud in the primary circuit to avoid radioactivity buildup and unexpected power transition in the plant. However, experiments on the crud are restricted in the laboratory because the crud is a highly radioactive material. The objective of this study is to develop a test method for simulating the deposition of crud in a nuclear power plant
2010-10-01
Energy Technology Data Exchange (ETDEWEB)
This paper describes statistical methods used to evaluate data for toluene (at several typical operating temperatures and humidity levels) and to determine which measure of humidity (relative or absolute) is more important in determining carbon adsorption efficiency. The water content of a solvent-laden stream is critical for its control via carbon adsorption, especially at relative humidities about 50-70%. (Relative humidity is the percent of saturation: absolute humidity is the total water content.)
1989-01-01
Energy Technology Data Exchange (ETDEWEB)
Yucca Mountain, Nevada is a potential site for a high-level radioactive-waste repository. Uncertainty and sensitivity analyses were performed to estimate critical factors in the performance of the site with respect to a criterion in terms of pre-waste-emplacement ground-water travel time. The degree of failure in the analytical model to meet the criterion is sensitive to the estimate of fracture porosity in the upper welded unit of the problem domain. Fracture porosity is derived from a number of more fundamental measurements including fracture frequency, fracture orientation, and the moisture-retention characteristic inferred for the fracture domain.
1993-01-01
Energy Technology Data Exchange (ETDEWEB)
Some of the known toxic effects of lead in mammals including man are, impaired heme synthesis, anemia, nepatopathy, nephropathy, behavioral disorders and neuropathy. However, very little is known about the effect of lead on endocrine physiology. Some data are available on lead induced impairment of thyroid function in occupationally exposed men and experimental rats. As lead nitrate is largely consumed through water and food, in this study the wild rodents Funambulus pennanti were administered lead through their drinking water and their thyroid structure, radioiodine 131-I percentage uptake and protein bound iodine (PBI) level were assessed.
1987-06-01
International Nuclear Information System (INIS)
This document is a summary of the available information on the thermo-hydro-mechanical properties of the bentonite barrier of a high-level radioactive waste repository and of the processes taking place in it during the successive repository operation phases. Mainly the thermal properties, the volume change processes (swelling and consolidation), the permeability and the water retention capacity are analysed. A review is made of the existing experimental knowledge on the modification of the these properties by the effect of temperature, water salinity, humidity and density of the bentonite, and their foreseen evolution as a consequence of the processes expected in the repository. The compiled evolution refers mostly to the FEBEX (Spain), the MX-80 (USA) and the FoCa (France) bentonite, considered as reference barrier materials in several European disposal concepts. (Author) 102 refs.
2004-05-01
PSA for CANDU-6 pressurized heavy water reactors: Wolson Units 2,3 and 4 of Korea
International Nuclear Information System (INIS)
Level 1 and 2 probabilistic safety assessments (PSAs) for both internal and external events are being performed to meet one of the conditions for a construction permit for Wolsong units 2, 3, and 4 in Korea. These units are CANDU-6 Pressurized Heavy Water Reactors (PHWRs), and the study is the first comprehensive level 1 and 2 PSAs for CANDU type plants in the world. The detailed PSA includes and extensive fault tree, event tree analysis, human reliability analysis, and common cause failure analysis. Event trees have been developed for 35 internal initiating event groups. The preliminary results show that the total core damage frequency for Wolsong units 2, 3, and 4 each is similar to that for a typical PWR plant. (author).
1997-06-01
International Nuclear Information System (INIS)
The loss of seal of the H9 channel in vacuum, freeing the entire cross section of the front part, leads to a fast leak that progresses rapidly. The effect of depressurizing the reflector can leads to shutdown of the shutdown rod pumps. The source changer associated with the channel fills completely before the valve closes. All of the leak water remains contained within the source changer containment. After the valves open, cooling of the fuel element is handled by natural convection, requiring a reversal of the flow between the plates. This changeover, which takes place at a relatively low pressure level, could lead to local boiling in the fuel element. Consequently, irreversible transformations cannot be excluded as possibilities for the fuel element and even for the control rod. Subsequently, the can is refilled with heavy water with establishment of the usual pressure levels.
Environmental surveillance at Hanford for CY-1979
Energy Technology Data Exchange (ETDEWEB)
Environmental data were collected for most environmental media including air, Columbia River water, external radiation, foodstuffs (milk, beef, eggs, poultry, and produce) and wildlife (deer, fish, and game birds), as well as soil and vegetation samples. In general, offsite levels of radionuclides attributable to Hanford operations during 1979 were indistinguishable from background levels. The data are summarized in the following highlights. Air quality measurements of NO/sub 2/ in the vicinity of the Hanford Site and releases of SO/sub 2/ onsite were well within the applicable federal and state standards. Particulate air concentrations exceed the standards primarily because of agricultural activities in the area. Discharges of waste water from Hanford facilities in the Columbia River under the National Pollution Discharge Elimination System (NPDES) permit were all within the parameter limits on the ...
1980-04-01
Chromate Transport through Surfactant-Modified Zeolite Columns
British Library Electronic Table of Contents (United Kingdom)
Abstract Remediation of ground water containing anionic contaminants presents a great challenge. Because of its low cost, surfactant-modified zeolite (SMZ) has been studied for >10 years for potential uses as permeable barrier materials to remove anionic contaminants from water. In this study, zeolite aggregates with particle size of 3.4 to 4.8 mm were modified by hexadecyltrimethylammonium (HDTMA) bromide, a cationic surfactant, to a surfactant loading level of 80 mmol/kg and a concurrent counterion bromide loading level of 34 mmol/kg. While no retardation of chromate transport was observed for unmodified columns, a retardation factor of 60 was found for chromate transport through the SMZ columns. Slow but persistent desorption of HDTMA occurred throughout the chromate transport experimen...
2006-01-01
Beverage iodine levels in Germany
British Library Electronic Table of Contents (United Kingdom)
Sales of iodized table salt (household use, bulk containers) have been flat in Germany since 1996/1997. Nevertheless, the amount of iodide excreted with the urine has been steadily increasing in the German population since 1993. We investigated the beverage iodine levels as possible source of the increased input of iodine into the food chain. No systematic studies on this topic have yet been carried out in Germany. A total of 510 samples were drawn from large grocery discounters who supply all German states with their products (35% fruit and vegetable juices, 35% beers, 10% pooled milk and yoghurt drinks, 10% mineral water, 10% soda). (1) Water-based beverage samples are prepared by solid-phase extraction and iodine concentration is determined by HPLC and electrochemical detection, (2) the...
2009-01-01
A model for the calculation of vent clearing transients in pressure suppression systems
International Nuclear Information System (INIS)
For the layout of a pressure suppression system of a light water cooled reactor (boiling water reactor) it is important to know the time dependent behavior of the vent clearing transient after a loss-of-coolant accident for two main reasons: time of the end of the vent clearing transient influences strongly the pressure and temperature maxima in the drywell and wetwell. Time-dependent behavior of the vent clearing transient influences pressure loads in the condensation pool of the wetwell and therefore pressure induced stresses to the structure. The time-dependent behavior of the water masses in the vent pipes and wetwell are described by the basic equations for a nonstationary incompressible friction flow: momentum equation, continuity equation and a correlation for the variation of the state of the gas volume in the wetwell above the water level. After many algebraic operations ...
1975-09-01
Timber-Fish-Wildlife (TFW) Monitoring
Timber-Fish-Wildlife (TFW) Monitoring http://www.nwifc.wa.gov/TFW/ - a cooperative, inter-agency monitoring effort ... ...
Monitoring for adverse drug reactions
UK PubMed Central (United Kingdom)
Monitoring describes the prospective supervision, observation, and testing of an ongoing process. The result of monitoring provides reassurance that the goal has been or will be achieved, or suggests...Full Text Available
2006-04-01
Manitoba Hydro long-term high-voltage transmission line magnetic field monitoring project
International Nuclear Information System (INIS)
As part of the licensing process to construct a new 230 kV transmission line on an existing right-of-way in Manitoba, an electrical effects study was conducted in 1998. The study was part of the environmental assessment program crucial in obtaining government approval to construct the line. Some residents living adjacent to the new transmission circuit expressed concerns about alleged adverse health effects associated with long-term exposure to magnetic fields from high voltage transmission lines. In order to verify the accuracy of the predicted magnetic field levels submitted to the regulatory body in the the electrical effects study and to instill confidence in the residents of the affected communities, a three-year magnetic monitoring project was conducted between 2003 and 2005 along the right-of-way after the new 230kV transmission line was energized by Manitoba Hydro. This paper described the monitoring program, with ...
2008-10-19
Energy Technology Data Exchange (ETDEWEB)
Monitoring of groundwater quality from boreholes in and around the former Yotsugi open-pit mining site in the Ningyo-toge Environmental Engineering Center, JNC, have been carried out to estimate extent and quality of contaminated water plume from the buried heap-leaching residue. In this report, data collected from 1979 to 1998 fiscal year were listed and their spatial and time variation of physicochemical parameters, uranium and radium were also summarized. Additionally, groundwater sampler has been improved and analytical method has been modified. Some results from groundwater quality were; 1. Generally, electric conductivity and concentrations of uranium and radium outside of the site tend to lower than one from the inside area. 2. Data from borehole No. 13, installed outside of the site, exceptionally little higher than one from the inside area. (author)
1999-08-01
Measuring instrument for radiometric monitoring of solids and heavy metals in water
International Nuclear Information System (INIS)
A combination of measuring instruments, consisting of a Beta-Sedimeter and a radionuclide X-ray fluorescence instrument, is described. With the Beta-Sedimeter the C-14-radiation is measured. Through direct irradiation with photons of a Pu238-source in an ancillary irradiation chamber and energy dispersing measurement of the K- and L-radiation resp. of the excited heavy metals with the aid of a Si(Li)-semiconductor detector and a 4-channel analyzer the heavy metal concentrations of the heavy metals Zn, Cr, Ni and Pb are determined. For the determination of cadmium the indirect excitation with Am-241 and Dy-targets is described. The system produces records and operates fully automatically in a step-by-step mode with a testing cycle of 45 minutes. In connection with the process monitoring of the wastewater from a zinc plating plant during a period of 8 months the concentration of the solid material and of the metals Cr and Zn, which were considered to be ...
1979-01-01
Energy Technology Data Exchange (ETDEWEB)
Gas transmission pipelines are susceptible to both internal (gas side) and external (soil side) corrosion attack. Internal corrosion is caused by the presence of salt laden moisture, CO{sub 2}, H{sub 2}S, and perhaps O{sub 2} in the natural gas. Internal corrosion usually manifests itself as general corrosion. However, the presence of chlorides in entrained water also can lead to pitting corrosion damage. The electrochemical noise technique can differentiate general from localized corrosion and provide estimates of corrosion rates without external perturbation of the corroding system. It is increasingly being applied to field and industrial installations for in situ corrosion monitoring. It has been used here to determine its suitability for monitoring internal and external corrosion damage on gas transmission pipelines. Corrosion measurements were made in three types of environments: (1) aqueous solutions typical of those ...
2003-03-16
Energy Technology Data Exchange (ETDEWEB)
Individual monitoring of personal exposure to inhalation of uranium oxides throughout the manufacture of fuel for pressurized water reactor (PWR) includes lung gamma-spectrometry, fecal analysis and urine analysis. Examination of the results shows the following: internal exposure is the consequence of repeated intake incidents as revealed by early peaks of urinary and particularly fecal elimination; a shift is often observed with the results of aerosol concentration measured through air collectors; the measured variations of uranium lung incorporations are relatively fast (apparent mean period 165 d). Correct evaluation of the effective dose equivalent from inhalation requires further information concerning the aerosol size distribution at work stations, the physico-chemical characteristics of the product leading to an estimate of its actual biological solubility, and the measurement of the fraction of aerosol liable to intake with an ...
1989-01-01
Energy Technology Data Exchange (ETDEWEB)
The implementation of satellite remote sensing data for monitoring anthropogenic pollution in the USSR is described. Space-based monitoring systems offer the opportunity to identify pollution sources, track the spread of pollutants on the surface and in the air, and characterize land use patterns that cause erosion. Furthermore, vegetation under attack by polluting agents can be recognized by color changes, and water pollution in lakes, coastal zones, and in rivers near industrial areas and ports can be measured for the total affected area. The data have thus far been taken with instrumentation on board the Salyut space station, the Meteor-Priroda satellite, and from the Landsat MSS scanner. It is noted that the transboarder transport of pollutants necessitates sharing data with agencies of other nations, and that a data base must be developed to define procedures and instrumentation for given pollutants, algorithms for ...
1983-01-01
Whole Catchment Land Cover Effects on Water Quality in the Lower Kaskaskia River Watershed
British Library Electronic Table of Contents (United Kingdom)
Agricultural runoff is a major non-point source pollutant and is the leading impairment of streams and rivers in the USA. This study examined the effects of agricultural, forest and urban land cover on water quality at the watershed level. Forty-three catchments ranging from 12 to 50?km2 were selected based on a land cover gradient within Lower Kaskaskia River Watershed in Illinois. Grab samples were collected and analyzed for nutrients, bacteria, and total suspended solids (TSS). Forest land cover was included in six of the ten regression models produced. Four of these regression models were for base flow conditions, suggesting that forest land cover had a significant impact on base flow water quality. Urban land cover was also included in six of the regression models. However, the majori...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
It is an object of the claimed invention to combine chemical treatment with microfiltration process to treat groundwater, leachate from contaminated soil washing, surface and run-off waters contaminated with toxic metals, radionuclides and trace amounts of organics from variety of sources. The process can also be used to treat effluents from industrial processes such as discharges associated with smelting, mining and refining operations. Influent contaminants amenable to treatment are from a few mg/L to hundreds of mg/L. By selecting appropriate precipitation, ion exchange and adsorption agents and conditions, efficiencies greater than 99.9 percent can be achieved for removal of contaminants. The filtered water for discharge can be targeted with either an order of magnitude greater or lower than contaminant levels for drinking water.
1992-12-31
British Library Electronic Table of Contents (United Kingdom)
The agricultural sector is probably the one that will suffer most directly from the climatic variations expected at the global level. In particular, the analysis of the changes expected in water availability and demand is fundamental in order to correctly establish both the present water resource management and the definition of new strategies. In this paper the time series of some climatic and agro-climatic indices in the Region of Umbria (Central Italy) have been analyzed with the aim of finding signs of climate changes and identifying the potential impacts on the agricultural water balance. The aforesaid indices include the precipitation, the mean maximum and minimum temperatures (Tmin, Tmax), the mean temperature range (DT), the reference evapotranspiration (ET0) and two drought indice...
2011-01-01
Photosynthesis responses to various soil moisture in leaves of Wisteria sinensis
British Library Electronic Table of Contents (United Kingdom)
A study was conducted to determine the fitting soil moisture for the normal growth of two-year-old W. sinensis (Sims) Sweets by using gas exchange technique. Remarkable threshold values of net photosynthetic rate (Pn), transpiration rate (Tr) and water use efficiency (WUE) were observed in the W. sinensis leaves treated by various soil moisture and photosynthetic available radiation (PAR). The fitting soil moisture for maintaining a high level of Pn and WUE was in range of 15.3%?26.5% of volumetric water content (VWC), of which the optimal VWC was 23.3%. Under the condition of fitting soil moisture, the light saturation point of leaves occurred at above 800?mol?m?2?s?1, whereas under the condition of water deficiency (VWC, 11.9% and 8.2%) or oversaturation (VWC, 26.5%), the light saturatio...
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
Lead is a heavy metal which is widely used in paint industry, pigments, dyes, electrical components and electronics, plastic chemicals and in various other things. Since some of the lead salts are soluble in water, lead presents a potential threat to aquatic organisms. Studies dealing with invertebrates include those on mortality, growth and lead uptake in Lymnaea palustris and bioaccumulation of heavy metals in oysters and mussels. Little information exists regarding the effect of lead on the fresh water crustaceans. Hence the present investigation has been undertaken to study the uptake and loss of lead on exposure to subtoxic levels or organic and inorganic lead.
1987-07-01
A study of binary mixture boiling: boiling site density and subcooled heat transfer
Energy Technology Data Exchange (ETDEWEB)
(Boiling site densities and heat-transfer coefficients have been measured for ethanol-water and ethanol-benzene mixtures at 1.01 bar for a heated vertical brass disk. A strong effect of composition on the boiling site density was observed, which was attributed to the nature of the activation of the boiling surface and mass diffusion effects. The boiling heat-transfer coefficient was found to decrease with increasin subcooling, but for the mixtures at a given level of subcooling the decrease was less than that for the single components and azeotropic mixtures.) The heat-transfer coefficient at a given heat flux was seen to be quite insensitive to the very large increase in boiling site density in comparing the pure water and the ethanol-water azeotrope results, leading one to question pool boiling models that predict heat-transfer rates on the basis of boiling site density.
1985-05-01
1991 ice jamming along the Saint John River: a case study
Energy Technology Data Exchange (ETDEWEB)
Field investigations of major and damaging ice jamming on the Saint John River at Dickey, Maine , and at Sainte-Anne de-Madawaska, New Brunswick, in 1991, were described. The investigations included measurement of water surface profiles and shear wall heights at both sites. The measurements were supplemented by information from local observers and data collection agencies. Using a simplified equilibrium analysis, ice jam thickness and water level at the Dickey site was found to be generally in agreement with observed values. At Sainte-Anne-de-Madawaska sufficient data was obtained to construct and calibrate the numerical model RIVJAM which determined the configuration of the jam in nonequilibrium reaches. Use of the model enabled the successful reproduction of a measured water profile along the jam and the prediction of the approximate thickness of the jam, which was generally less than the measured ...
1996-04-01
Strategy and management of network security at KEK
International Nuclear Information System (INIS)
Recently the troubles related to the network security have often occurred at KEK. According to their security policy, the authors have started the strategy against the daily attacks. It consists of two fundamental things; the monitoring and the access control. To monitor the network, the authors have installed the intrusion detection system and have managed it since 1998. For the second thing, the authors arranged three categories to classify all hosts (about 5000 hosts) at KEK according to their security level. To realize these three categories, the authors filter the incoming packet from outside KEK whether it has a SYN flag or not. The network monitoring and the access control produced good effects in keeping the security level high. Since 2000 the authors have started the transition of LAN from shared-media network to switched network. Now almost part of LAN was re-configured ...
2001-09-03
International Nuclear Information System (INIS)
An experiment was performed with a mock-up of the core of the Fast Flux Test Facility (FFTF) reactor to evaluate three reactivity measurement methods for application to liquid-metal fast breeder reactors (LMFBR): modified source multiplication measurements with the low-level flux monitor for refueling (35 dollars subcritical) of FFTF, noise analysis to 35 dollars subcritical, and inverse kinetics rod drop to 12 dollars subcritical. To investigate the spatial dependence of these measurement methods and to resolve discrepancies previously reported, detectors were placed in the core, reflector, and radial shield, and experimental data were collected with the reactivity at near delayed criticality to 35 dollars subcritical. Conclusions from this experiment are the following. Low-level flux monitors in the shield of the FFTF will be adequate for reactivity surveillance during refueling, using the modified ...
International Nuclear Information System (INIS)
PWR plants have made efforts to maintain the long-term integrity of the steam generators (SG) by reducing the amount of corrosion products entering the secondary side of the SG. Iron entered the SG can cause several problems: degraded heat conductivity of the SG tubes in locations where iron is deposited, water level oscillations in the SG due to tube support plate hole blockage, and initiation and propagation of inter-granular attacks (IGA) and stress corrosion cracking (SCC). One of the most effective measures, high all-volatile treatment (AVT) chemistry has been applied to actual plants to reduce the flow-accelerated corrosion (FAC) coming from the carbon steel piping. The secondary water chemistry at Genkai NPS 1 and 2 changed, from the Low AVT chemistry to the High AVT chemistry, in November 2006. In this paper, we will describe the results of experiments in applying the use of High pH water in the ...
2009-02-01
Energy Technology Data Exchange (ETDEWEB)
An experimental investigation of a humidification-dehumidification desalination (HDD) process using solar energy at the weather conditions of Suez City, Egypt, is presented. A test rig is designed and constructed to conduct this investigation under different environmental and operating conditions. The test rig consists of a solar water heater (concentrator solar collector type), solar air heater (flat plate solar collector type), humidifier tower and dehumidifier exchanger. Different variables are examined including the feed water flow rate, the air flow rate, the cooling water flow rate in the dehumidifier and the weather conditions. Comparisons between the experimental results and other published results are presented. It is found that the results of the developed mathematical model by the same authors are in good agreement with the experimental results. The tested results show that the productivity of the system is ...
2004-05-01
International Nuclear Information System (INIS)
An experimental investigation of a humidification-dehumidification desalination (HDD) process using solar energy at the weather conditions of Suez City, Egypt, is presented. A test rig is designed and constructed to conduct this investigation under different environmental and operating conditions. The test rig consists of a solar water heater (concentrator solar collector type), solar air heater (flat plate solar collector type), humidifier tower and dehumidifier exchanger. Different variables are examined including the feed water flow rate, the air flow rate, the cooling water flow rate in the dehumidifier and the weather conditions. Comparisons between the experimental results and other published results are presented. It is found that the results of the developed mathematical model by the same authors are in good agreement with the experimental results. The tested results show that the productivity of the system is ...
2004-05-01
Energy Technology Data Exchange (ETDEWEB)
An experimental investigation of a humidification-dehumidification desalination (HDD) process using solar energy at the weather conditions of Suez City, Egypt, is presented. A test rig is designed and constructed to conduct this investigation under different environmental and operating conditions. The test rig consists of a solar water heater (concentrator solar collector type), solar air heater (flat plate solar collector type), humidifier tower and dehumidifier exchanger. Different variables are examined including the feed water flow rate, the air flow rate, the cooling water flow rate in the dehumidifier and the weather conditions. Comparisons between the experimental results and other published results are presented. It is found that the results of the developed mathematical model by the same authors are in good agreement with the experimental results. The tested results show that the productivity of the system is ...
2004-05-01
Restoration of a forested wetland ecosystem in a thermally impacted stream corridor
Energy Technology Data Exchange (ETDEWEB)
The Savannah River Swamp is a 3,020 Ha forested wetland on the floodplain of the Savannah River and is located on the Department of Energy`s Savannah River Site (SRS). Major impacts to the swamp hydrology occurred with the completion of the production reactors and one coal-fired powerhouse at the SRS in the early 1950`s. Water was pumped from the Savannah River, through secondary heat exchangers of the reactors, and discharged into three of the tributary streams that flow into the swamp. This continued from 1954 to 1988 at various levels. The sustained increases in water volume resulted in overflow of the original stream banks and the creation of additional floodplains. Accompanying this was considerable erosion of the original stream corridor and deposition of a deep silt layer on the newly formed delta. Heated water was discharged directly into Pen Branch and water temperature in ...
1995-09-01
Influence of fly ash on soil physical properties and turfgrass establishment
Energy Technology Data Exchange (ETDEWEB)
A field study (1993-96) assessed the benefits of applying unusually high rates of coal fly ash from power plants as a soil amendment to enhance water retention of soils without adversely affecting growth and marketability of the turf species, centipedegrass (Eremochloa ophiuroides (Munro) Hack.) A Latin Square plot design was employed that included 0 (control, no fly ash applied), 280, 560 and 1120 MgHa {sup -1} application rates of unweathered precipitator fly ash. The fly ash was spread evenly over each plot area, rototilled, and allowed to weather under natural conditions for 8 months before seeding. High levels of soluble salts, indicated by the electrical conductivity of soil extracts, in tandem with an apparent phytotoxic effect from boron, apparently inhibited initial plant establishment as shown by substantially lower germination counts in treated soil. However, plant height and rooting depth were not adversely affected, as were the dry ...
2001-04-01
Energy Technology Data Exchange (ETDEWEB)
Water from small scale purification plants is a low cost alternative for consumers in comparison to the bottled commercial presentations. Because of its low cost per liter, the consumption of this product has increased in recent years, stimulating in turn the installation of purification systems for these small businesses. The purpose of this study was to estimate the efficiency of small scale purification systems located in the cities of Zacatecas and Guadalupe, Zacatecas, to reduce the radioactive content of water. It was measured the total alpha and beta activity in water samples of entry and exit to process, through the liquid scintillation technique. In general it was observed that the process is more efficient in removing alpha that beta activity. The fraction of total alpha activity removed varied between 27 and 100%, while between 0 and 77% of the total beta activity was removed by the analyzed plants. In all cases, ...
2009-10-15
Urban growth, climate change, and freshwater availability
Nearly 3 billion additional urban dwellers are forecasted by 2050, an unprecedented wave of urban growth. While cities struggle to provide water to these new residents, they will also face equally unprecedented hydrologic changes due to global climate change. Here we use a detailed hydrologic model, demographic projections, and climate change scenarios to estimate per-capita water availability for major cities in the developing world, where urban growth is the fastest. We estimate the amount of water physically available near cities and do not account for problems with adequate water delivery or quality. Modeled results show that currently 150 million people live in cities with perennial water shortage, defined as having less than 100 L per person per day of sustainable surface and groundwater flow within their urban extent. By 2050, demographic growth will increase this figure to ...
2011-04-12
Radon concentrations and absorbed dose measurements in a Pleistocenic cave
International Nuclear Information System (INIS)
Radon concentration measurements were carried out using solid-state nuclear track-etch detectors (SSNTDs) type CA 80-15 cellulose nitrate films, in a Pleistocenic cave at Petralona, in Halkidiki, Northern Greece, at 55 km from the city of Thessaloniki. Radon levels as high as 88 kBqxm"-"3 (2.38 nCi x l"-"1) have been recorded inside the cave equivalent to 11.90 WL in terms of occupational exposure to radon and its decay products. Absorbed dose rates were performed using TL dosimeters, type TLD-200 (CaF_2-Dy) in a continuous monitoring program (integrated measurements). Dose rate levels as high as 110 nGy x h"-"1 were recorded inside the cave. In interpreting the high levels of radiation doses, radioactivity measurements regarding the naturally occurring "2"3"8U, "2"3"2Th and "4"0K radionuclides were carried out in various speleothems found at different sites in the cave. (author)
2003-10-01
Quality assurance requirements and description for the Civilian Radioactive Waste Management Program
International Nuclear Information System (INIS)
The Quality Assurance Requirements and Description (QARD) is the principal quality assurance document for the Civilian Radioactive Waste Management Program (Program). It establishes the minimum requirements for the Quality Assurance Program. The QARD contains regulatory requirements and program commitments necessary for the development of an effective quality assurance program. Quality assurance implementing documents must be based on, and consistent with, QARD requirements. The QARD applies to the following: (1) acceptance of spent nuclear fuel and high-level radioactive waste; (2) transport of spent nuclear fuel and high-level radioactive waste; (3) the Monitored Retrievable Storage (MRS) facility through application for an operating license; (4) Mined Geologic Disposal System (MGDS), including the site characterization activities (exploratory studies facility (ESF) and surface based testing), through application for an ...
Environmental hardening of a mobile-manipulator system for nuclear environments
International Nuclear Information System (INIS)
This research report discusses the radiation hardening of a commercially available mobile robot, the REMOTEC ANDROS. This hardening effort is culminating in the availability of a megarad hardened mobile platform to access areas in nuclear facilities with extremely high levels of radiation (0.1 to 1 Mrad). These radiation levels may be encountered both during routine repair and monitoring activities and accident situations. The project has completed a phase-I U.S. Department of Energy Small Business Innovative Research contract and is now in a phase-II effort with completion scheduled in early 1995. The research involves the evaluation of the material and electrical components of an ANDROS robot to determine the anticipated radiation hardness of the current production version and evaluation of the components that must be replaced or modified to harden the system to higher radiation levels. The work being ...
1993-11-14
Energy Technology Data Exchange (ETDEWEB)
Due to legal restrictions, the German hard coal mining company Deutsche Steinkohle AG (DSK) is obliged to conduct a monitoring on surface changes (subsidence) caused by mining activity (e.g. topographic surface, groundwater, water, flora and fauna, soil). To fulfill legal demands and to do this effectively, process chains by use of Photogrammetry, Remote Sensing and Geo-Informationssystems (GIS) have been established. Photogrammetric methods are used to generate high resolution Digital Elevation Models (DEM) from which in combination with subsidence data geometrical changes at the topographic surface are deduced. The potential use of active sensors (Laser Scanning and Synthetic Aperture Radar Systems) to deduct DEM has been investigated. The applicability of SAR satellite data to detect and observe subsidence and resulting movements - point wise or with spatial extent - using differential SAR Interferometry (dInSAR) as well as persistent ...
2006-03-15
Energy Technology Data Exchange (ETDEWEB)
There is an urgent need to monitor the condition of fluid-filled taped (FFT) cables. The Dissolved-Gas Analysis (DGA) technique that has been successfully applied to power transformers holds great potential for the preventive maintenance of FFT cables. However, before this emerging technique can be properly applied to cables, a suitable fluid sampling and subsequent gas analysis method had to be developed, including the generation of both laboratory and field data to aid in data interpretation. Data on gas saturation levels in various cable fluids have been presented. This paper describes a novel method developed specifically for FFT cables and discusses field results so obtained. The type, distribution and concentration of gases from fluid alone and paper alone under electrical stress has been presented, including the differences between normal and not-so-normal cable systems as demonstrated by DGA. The concept of wet tensile strength has been ...
1994-12-31
The SysMES framework: System management for networked embedded systems and clusters
Energy Technology Data Exchange (ETDEWEB)
The ALICE heavy-ion particle physics experiment is currently being built at CERN near Geneva. It will use a PC cluster of 900 dual-processor machines for the last stages of the data readout process and a network of 400 microcomputers for the configuration and control of the cluster nodes. One of the most important objectives to be achieved in such experiments is to guarantee the utilized devices are running correctly during the experiment life-time. A second aspect is the extremely high availability and reliability requirements of the applications being run, the so called high level trigger (HLT). The SysMES framework is a scalable, decentralized, fault tolerant, dynamic, rule based tool set for the monitoring of networks of target systems and applications. The management algorithms consist of the following steps: system and application monitoring, recognition of undesirable states, event (message) generation, local event ...
2008-07-01
Monitoring system assists in dual-fuel engine knock prevention
Energy Technology Data Exchange (ETDEWEB)
ABB Industrietechnik AG recently has introduced an augmented version of its Cyldeyt cylinder pressure monitoring system aimed at spark-ignited and diesel/gas, dual-fuel engines. In addition to recording and evaluating cylinder pressure as a means of assessing engine condition, the new Cyldet version now evaluates the cylinder pressure signals to provide protection against pre-ignition related damage. When pre-ignition reaches critical levels, the Cyldet computer relays alarm signals in two stages to the overriding engine control system of the power plant. On receiving the first-stage alarm signal, the engine control system is programmed to adjust one or more engine settings to eliminate preignition - a typical adjustment is to lower charge-air temperature, for example. If such measures fail to eliminate pre-ignition, in the case of a dual-fuel engine, a second alarm signal triggers a reduction in engine load or, as last resort, changeover of ...
1995-03-01
Environmental impact assessment around TRIGA research reactor
International Nuclear Information System (INIS)
Population distribution, atmospheric change, X/Q, characteristics of terrestrial ecosystem around Seoul site were surveyed. Environmental radiation and radioactivities such as gross#alpha#, gross#beta#, Cs-137, Sr-90 and H-3 of various environmental samples were analyzed. The values of environmental radiation dose tended to increase gradually in the light of the recent five years' results of environmental radiation monitoring around the nuclear power plants from 1980 to 1984, however, the changes were not significant. In addition, continuous assessment of environmental radiation monitoring on the roofs of main building and life science building at KAERI showed that the environmental radiation dose tended to increase a little during the night time. Judging from the above results, it is concluded that environmental contamination level by radioactive materials could be ignored in the case of radioisotope production or ...
1985-04-01
Enhancement of N-nitrosamine formation on granular-activated carbon from N-methylaniline and nitrite
Energy Technology Data Exchange (ETDEWEB)
Sterile aqueous N-methylaniline solutions were allowed to equilibrate at various nitrite, F-400 granular-activated carbon, and pH levels for 1 week. The aqueous and activated carbon phases were extracted and analyzed for nitrosamines relative to an added internal standard. Selected ion monitoring GC/MS, utilizing continuous monitoring of the NO/sup +/ ion (m/z 29.9980) characteristic of nitrosamines, at medium resolution (R = 2500-3000) was applied to quantitatively measure nitrosamines at picograms per microliter concentrations. This method selected for nitrosamine products only and eliminated interferences from non-nitrosamine reaction products. Results indicate that the pressure of granular-activated carbon significantly enhanced the formation of nitrosamine from N-methyl-aniline (F = 145, P< 0.0001). The amount of N-nitrosomethylaniline formed in the presence of activated carbon was 75 times more than that formed in ...
1986-10-01
Energy Technology Data Exchange (ETDEWEB)
Biomonitoring of human populations for exposure to genotoxic/clastogenic agents in the environment or the workplace must depend upon statistical tests for elevations in the frequencies of the biological endpoints being monitored, usually chromosomal aberrations (CA), micronuclei (MN), or sister chromatid exchanges (SCE) in peripheral blood lymphocytes. Statistical tests are based, in turn, upon certain assumptions regarding the distribution of the test statistic. When they are often not recognized as such, tests of significance can be in error, and any conclusion drawn that there is or is not a statistically significant difference between one population sample and another maybe erroneous. In population monitoring this means either false negatives or false positives can result and it is hard to know which is worse. Furthermore, even the intelligent design of studies whose object is to test for an elevated level in an exposed ...
1992-12-31
GAO's review of the H-Coal and Exxon projects showed inadequacies in DOE's contracting practices and a failure by DOE to properly plan, manage, and monitor, especially the H-Coal project. The initial Government-industry H-Coal agreements regarding the level of investment by private sponsors and the ceilings imposed on sharing in cost growth were imbalanced. Larger investments by private sponsors and sharing of cost growth provides an incentive to private sponsors to control costs and helps to assure that each party is fully committed to the success of the project. DOE started the H-Coal project prematurely before sufficiently detailed designs were available and without adequate project planning for functions such as construction scheduling, materials handling, inventory systems, and quality control. DOE staffing was inadequate at both projects to effectively monitor progress and contribute to timely ...
1981-02-04
Clinical-HINTS: integrated intelligent ICU patient monitoring and information management system.
Clinical-HINTS (Health Intelligence System) is a horizontally integrated decision support system (DSS) designed to meet the requirements for intelligent real-time clinical information management in critical care medical environments and to lay the foundation for the development of the next generation of intelligent medical instrumentation. The system presented was developed to refine and complement the information yielded by clinical laboratory investigations, thereby benefiting the management of the intensive care unit (ICU) patient. More specifically, Clinical-HINTS was developed to provide computer-based assistance with the acquisition, organisation and display, storage and retrieval, communication and generation of real-time patient-specific clinical information in an ICU. Clinical-HINTS is an object-oriented system developed in C+2 to run under Microsoft Windows as an embryo intelligent agent. Current generic reasoning skills include perception and reactive cognition of patient ...
1997-01-01
Energy Technology Data Exchange (ETDEWEB)
In this work, the thermodynamic behaviour of single-stage horizontal spray coolers with one or more spray levels is experimentally examined. Further, a spray cooler calculation model was developed, in order to describe the processes and to make a comparison of the results of calculation and measurement. The state of the mine climate and the cold water are taken as the thermodynamic reference. (orig.).
1988-09-14
The research on new production technique of yellow cake
International Nuclear Information System (INIS)
As a new production technique of yellow cake, resorption with loaded resin-elution with acid ammonium nitrate-precipitation in two steps is studied. The results show that the produced yellow cake by the new production technique has better performance of settlement, filtration and dehydration. Each index of yellow cake accords with the first grade level issued by CNNC without washing, uranium and water content are 70% and 25%, respectively
2001-11-01
Rayleigh scattering of Moessbauer radiation in hyaluronate oriented fibres
Energy Technology Data Exchange (ETDEWEB)
The Rayleigh scattering of Moessbauer radiation has been measured on highly oriented fibres of Na-hyaluronate at different hydration levels. The elastic- and-inelastic-scattering intensities, measured as a function of the scattering vector Q, have provided information on the dynamic structuring of the water molecules to the polysaccharidic chains.
1996-02-01
Poster 20. Analysis of chemical environment conditions in boiling zones
International Nuclear Information System (INIS)
Boiling phenomenon is responsible for impurities concentration in the liquid phase and then can involve chemically aggressive conditions. This paper presents the methodology developed by NOVATOME to know the water quality conditions in the boiling zone and under deposits, in order to improve corrosion tests and materials reliability and safety. Calculations show that concentration of chloride and sodium hydroxide for example can reach significant levels which may lead to corrosion risks. (author).
Mathematical and physical model of steam-water mixture flow in horizontal steam generator
International Nuclear Information System (INIS)
A mathematical and physical model was constructed describing the hydrodynamics of the two-phase mixture in the horizontal steam generator. The HP 9830 A desk-top calculator was used for the computations. The output variable of the solution was the level shape. A quantitative and qualitative comparison was made of the results of computations and experimental data. (author).
1982-10-01
Efficiency of preliminary transmutation of actinides before ultimate storage
International Nuclear Information System (INIS)
The concept of preliminary transmutation of minor actinides before placement to the long-term storage is considered. The purpose of such preliminary transmutation before ultimate storage is to incinerate a part of actinides and to transform another part into new actinides providing low level of radiotoxicity accumulated in the storage. Modes of transmutation in reactors of PWR, PHWR (CANDU), and Superfenix types are compared. Among power reactors, heavy-water PHWR type reactor is most acceptable for preliminary transmutation. (author)
2003-04-20
Effect of dietary constituents on the gastrointestinal absorption of /sup 203/Pb in man
Energy Technology Data Exchange (ETDEWEB)
The gastrointestinal absorption of lead was markedly increased in human subjects who had fasted before ingesting lead. Food in the gut was found to reduce lead absorption, and the effect of dietary constituents on /sup 203/Pb absorption was investigated. The greatest reduction in absorption was caused by minerals. This dependence of lead absorption on dietary constituents complicates the establishment of safe levels of lead in food and water.
1983-02-01
Cost-effectiveness analysis of effluent standards and limitations for battery manufacturing
Energy Technology Data Exchange (ETDEWEB)
The document reports the results of a cost-effectiveness analysis of alternative water pollution control regulations of the battery manufacturing industry. These regulations include effluent limitations and standards based on best practical control technology currently available, best available technology economically achievable, and pretreatment standards for new sources. For each of these regulations, EPA has identified several pollution control options, each with different levels of pollution abatement and compliance cost. The analysis is a tool for evaluating the options.
1984-02-01
A study was undertaken to examine the uptake, distribution, and interaction of five activation products (Co-57, Be-7, Cs-134, Rb-83, and Mn-54) within the biotic and abiotic components surrounding the waste treatment lagoons of the Los Alamos Meson Physic...
1989-01-01
UK PubMed Central (United Kingdom)
Experiments were conducted with field-grown cotton (Gossypium hirsutum L.) in 1985 and 1986 to determine effects of water deficit on levels of conjugated indole 3-acetic...Full Text Available
1988-01-01
CFD simulation of steam generator tube rupture thermal-hydraulics
Energy Technology Data Exchange (ETDEWEB)
Several steam generator tube rupture accidents have occurred at plants in the past. In this paper the Computational Multi-Fluid Dynamics (CMFD) investigation of the horizontal steam generator thermal-hydraulics during the tube rupture accident is performed. A guillotine of a steam generator U-tube is assumed with choked flow from the primary to the secondary side of the steam generator. We have computed water and steam velocity fields, steam volume fraction distribution on the steam generator secondary (shell) side, as well as the swell level increase. The simulation results are a support to the safety analyses of the steam generator tube rupture accident. Numerical simulation is performed with the multidimensional multi-fluid modelling approach. The two-phase flow around steam generator tubes in the bundle is modelled by the porous media approach. Interfacial mass, momentum and energy transfer are modelled with the closure laws. The governing ...
2004-07-01
100 Areas: (For Technical Progress Letter No. 97), May 7--13
Physics information for the D and F piles is presented. Thermal conductivity, reactivity, and irradiation levels are included. Concerning the cooling systems: process water control, pressure drip studies, purging studies, corrosion, and gun barrel clearance of expanded graphite are discussed. (GHH)
1946-05-17
International Nuclear Information System (INIS)
On the basis of soil losses records during 10 years, three levels of water erosion were established for two soil (Typical Hapludox and Oxic Dystropept) located on high and medium terraces of alluvial flat plain of piedmont in the Eastern Plains in La Libertad Research Center of CORPOICA. Eighteen 3 x 10 m"2 run-off plots were fitted out on a nonrandom arrangement of nine plots by landscape and three soil use and management treatments: zero grazing Brachiaria decumbens pasture for six years, up land rice, soybean and maize rotations for six years and bare soil for 10 years. Soil losses under these treatments allowed to define three degrees of erosion: slight (N_3 moderate (N_2) and severe (N_3) respectively. From each plot soil samples were taken at two depths for physical analyses. infiltration and resistance to cone penetration were measured in the field. Without exception water erosion produced a detrimental effect on ...
1999-12-01
Retinue of the beans roots growth by using neutron radiography technique
International Nuclear Information System (INIS)
Agricultural practices frequently cause the development of a soil compacted layer below the surface. These compacted layers restrict the root penetration into deeper layers of soil, in search for water. It is proposed to monitor, using Non Destructive Test, the roots growth due to the planting of standard seeds in different agricultural soils, in function of their compactness and humidity. It will be used the neutrons beams derived from an irradiation channel called J-9 of the Reactor Argonauta (IEN/CNEN), so that the neutron radiographic images of the soil-plant system can be obtained. Each root can be evaluated for its ability to penetrate into compacted soil layers; this fact would mean an optimization of agricultural harvests. (author)
2002-08-11
Restauration of the Clinton site; Restauration du site Clinton
Energy Technology Data Exchange (ETDEWEB)
Mining of copper and zinc took place at the Clinton Mine located in the Estrie region of Quebec between 1973 and 1975, during which time 115,000 tons of mineral were treated at the Solbec plant. In this poster presentation, the authors provided the background information pertaining to this mine and described the state in which it was in 1994. The pit was covered with good quality water, with a pH of 7,1 and copper and zinc content ranging between 0,1 and 0,6 mg/l, and iron ranging between 0,2 and 1,8 mg/l. The tailings basin drainage was found to have a pH of between 3,6 and 6,1. A program for the characterization of the site was implemented and the concept for the restauration of the Clinton site was developed and implemented. The work carried out at the site is discussed during this presentation as well as the monitoring taking place. 27 figs.
2000-07-01
British Library Electronic Table of Contents (United Kingdom)
A detailed knowledge about the dynamics of phytoplanktonic photosynthesis and respiration is crucial for the determination of primary productivity in open oceans as well as for biotechnological applications. The dynamics are best studied in photobioreactors that are able to simulate natural conditions in such, that light can be modulated not only diurnally but also mimicking effects of solar elevation angle from sunrise to sunset, variable cloudiness, light modulation in refractory sun flecks due to water waves, or light intermittence due to turbulent flow in dense suspensions. In addition, high performance photobioreactors ought to be able to monitor in real time photosynthetic and respiratory activities as well as culture growth. Here, we demonstrate performance of a newly designed bench...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
Papers from 3 separate conferences are given. The international coal conference covered: advances in control technologies; advances in remote sensing and monitoring; financing and marketing for the future; global climate; health and safety technology; and improving coal's image. Papers from the international minerals and metals conference covered; environmental challenges; financial trends; industry forecast; management strategies; technology advancement; and trade in a changing world. The U.S. issues conference discussed: access to public lands - can you mine if you can't look; innovative technologies in coal mining; innovative technologies in minerals and metals; managing human resource issues; management - controlling costs into the 21st century; and mine waste and water issues.
1992-01-01
Energy Technology Data Exchange (ETDEWEB)
This report discusses the UTR-10 reactor at Iowa State University which went critical on low enriched uranium (LEU) fuel on August 14, 1991. However, subsequent to the criticality experiments the fuel plates started to discolor. In addition, roll pins used to lift the fuel assemblies were discovered to be cracked. It was determined that these problems were due to chemical agents in the primary coolant water. The roll pins were replaced by solid stainless steel pins. The primary coolant was replaced and the reactor is currently in operation. Surveillance specimens will be used to monitor any possible future discoloration. The high enriched fuel (HEU) is being prepared for eventual shipment to a high enriched fuel receiving facility.
1992-08-01
Low enrichment fuel conversion for Iowa State University
Energy Technology Data Exchange (ETDEWEB)
This report discusses the UTR-10 reactor at Iowa State University which went critical on low enriched uranium (LEU) fuel on August 14, 1991. However, subsequent to the criticality experiments the fuel plates started to discolor. In addition, roll pins used to lift the fuel assemblies were discovered to be cracked. It was determined that these problems were due to chemical agents in the primary coolant water. The roll pins were replaced by solid stainless steel pins. The primary coolant was replaced and the reactor is currently in operation. Surveillance specimens will be used to monitor any possible future discoloration. The high enriched fuel (HEU) is being prepared for eventual shipment to a high enriched fuel receiving facility.
1992-08-01
British Library Electronic Table of Contents (United Kingdom)
Mining affects the environment in different ways depending on the physical context in which the mining occurs. In mining areas with an arid environment, mining affects plants? growth by changing the amount of available water. This paper discusses the effects of mining on two important determinants of plant growth?soil moisture and groundwater table (GWT)?which were investigated using an integrated approach involving a field sampling investigation with remote sensing (RS) and ground-penetrating radar (GPR). To calculate and map the distribution of soil moisture for a target area, we initially analyzed four models for regression analysis between soil moisture and apparent thermal inertia and finally selected a linear model for modeling the soil moisture at a depth 10?cm; the relative error o...
2009-01-01
IAEA RESEARCH CONTRACTS FIRST ANNUAL REPORT. Technical reports Series No. 4
Summaries are included of research contracts which expired prior to Dec. 31, 1960. The contracts were concerned with investigations of: electrophysiological responses of biological systems in nerve cells to irradiation with small doses of ionizing radiations; the mode of the protective action of certain sulfhydryl compounds against radiation effects on the synthesis of deoxyribonucleic acid, using tritium-labeled thymidine; development of a bubble chamber method of monitoring and dosimetry for Low fast neutron fluxes; effects of incorporated radioisotopes on the stability of genetic materials; interrelation of root and leaf absorption of radioisotopes in herbaceous plants; uptake of radioactive wastes by lowland rice from soils contaminated by irrigation water, and decontamination of the rice; and comparison between mutation rates induced by acute and chronic gamma irradiations. (B.O.G.)
1961-01-01
International Nuclear Information System (INIS)
The tide field at the time of liquid effluent discharging from Daya Bay nuclear power station, and the average water speed at the monitoring points in west Daya Bay from the time of discharging to the time of sampling were calculated by ADI (Alternating Direction Implicit) method. By comparing analysis, the difference of "3H diffusion between spring tide and neap tide (the expansion of "3H within one day of spring tide is greater than that within one day of neap tide) was found. So, an equivalent diffusion time is introduced to modify the original model, and a better attenuation relation between the average "3He concentration in west Daya Bay and the time since the liquid "3H discharging is obtained. (authors)
2006-07-01
Diversity of Tropical Tree Seedling Responses to Drought
British Library Electronic Table of Contents (United Kingdom)
ABSTRACT Drought is an important seedling mortality agent in dry and moist tropical forests, and more severe and frequent droughts are predicted in the future. The effect of drought on leaf gas exchange and seedling survival was tested in a dry-down experiment with four tree species from dry and moist forests in Bolivia. Seedlings were droughted and wilting stage and gas exchange were monitored. Drought led to a gradual reduction of photosynthesis and stomatal conductance over time, whereas respiration and photosynthetic water-use efficiency initially increased with drought and then declined. Seedlings gradually went through the different wilting stages, until they eventually died, but the trajectory differed for the four species. The strong relationship between wilting stage and photosynt...
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
A controlled field pilot has been developed in Bozeman, Montana, USA, to study near surface CO2 transport and detection technologies. A slotted horizontal well divided into six zones was installed in the shallow subsurface. The scale and CO2 release rates were chosen to be relevant to developing monitoring strategies for geological carbon storage. The field site was characterized before injection, and CO2 transport and concentrations in saturated soil and the vadose zone were modeled. Controlled releases of CO2 from the horizontal well were performed in the summers of 2007 and 2008, and collaborators from six national labs, three universities, and the U.S. Geological Survey investigated movement of CO2 through the soil, water, plants, and air with a wide range of near surface detection techniques. An overview of these results will be presented.
2009-10-20
ON-LINE MONITORING OF FLUE GAS DESULFURIZATION ...
... Title : ON-LINE MONITORING OF FLUE GAS DESULFURIZATION SCRUBBER CORROSION WITH ELECTROCHEMICAL TECHNIQUES. ...
1986-11-01
Indicators of safety culture - selection and utilization of leading safety performance indicators
International Nuclear Information System (INIS)
Safety indicators play a role in providing information on organizational performance, motivating people to work on safety and increasing organizational potential for safety. The aim of this report is to provide an overview on leading safety indicators in the domain of nuclear safety. The report explains the distinction between lead and lag indicators and proposes a framework of three types of safety performance indicators - feedback, monitor and drive indicators. Finally the report provides guidance for nuclear energy organizations for selecting and interpreting safety indicators. It proposes the use of safety culture as a leading safety performance indicator and offers an example list of potential indicators in all three categories. The report concludes that monitor and drive indicators are so called lead indicators. Drive indicators are chosen priority areas of organizational safety activity. They are based on the underlying safety model and ...
2010-05-01
Assessment of water quality around Jaduguda uranium tailings ponds
International Nuclear Information System (INIS)
The environmental impacts of uranium mining and milling activities are of great concern in many countries for the last three decades. These impacts range from the creation of massive stockpiles of radioactive and toxic waste rock and sand-like tailings to serious contamination of surface and groundwater with radioactive and toxic pollutants, and releases of conventional, toxic and radioactive air pollutants. Uranium mining is also associated with high concentrations of highly toxic heavy metals, which are a major source of surface and groundwater contamination. Depending upon the hydraulic properties of the fractures involved, contaminated ground water may be transported many miles from its point of origin before feeding into an aquifer. Tailings pond may contaminate the groundwater regime by continuous seepage and leaching of radionuclides and other toxic metals due to interaction of rain water through the tailings ponds. The uranium milling ...
2010-11-15
Energy Technology Data Exchange (ETDEWEB)
Ice jamming, known to cause high water levels at even moderate river flows, is described as both the main and least understood source of ice-related bridge damages. This paper describes a joint study by the New Brunswick Department of Transportation, the Department of the Environment, local governments, and the National Water Research Institute, designed to address problems associated with the interaction of ice jams and bridges. The study consists of collecting information at each of four sites in New Brunswick including: historical data on ice jam locations, causes, and water levels; channel bathymetry, width and slope within each study centred at the respective bridge; and documentation of ice conditions throughout the ice season, including measurement of ice cover thickness, observation of breakup mechanisms, times, causes, characteristics and possible impacts of ice jam ...
2000-12-01
Material and process improvements in condenser tubing
Energy Technology Data Exchange (ETDEWEB)
The reliability of the surface condenser is a key factor in plant performance level and maintenance cost optimization. This is especially the case for thermal nuclear plants where condenser raw wa-ter ingress can introduce contamination into the chemically-controlled, steam/water loop potentially causing damage to sensitive equipment. Two important parameters must be taken into account when attempting to optimize the quality and the reliability of condenser tubing. They include selecting the appropriate material according to the cooling water corrosion level present. A second and equally important parameter is the manufac-turing of the tubing product itself. This paper will identify methods to optimize manufacturing processes and improve tubing quality, according to VALTIMET's 30 years of condenser welded tubing production experience. Those methods complete the core ...
2010-07-01
Energy Technology Data Exchange (ETDEWEB)
Solid-state nuclear magnetic resonance (NMR) has been used to explore the nanometer-scale structure of Nafion, the widely used fuel cell membrane, and its composites. We have shown that solid-state NMR can characterize chemical structure and composition, domain size and morphology, internuclear distances, molecular dynamics, etc. The newly-developed water channel model of Nafion has been confirmed, and important characteristic length-scales established. Nafion-based organic and inorganic composites with special properties have also been characterized and their structures elucidated. The morphology of Nafion varies with hydration level, and is reflected in the changes in surface-to-volume (S/V) ratio of the polymer obtained by small-angle X-ray scattering (SAXS). The S/V ratios of different Nafion models have been evaluated numerically. It has been found that only the water channel model gives the measured S/V ratios in the ...
2010-03-15
Energy Technology Data Exchange (ETDEWEB)
The authors observed euhedral crystals in Manatee soil in a citrus grove in St. Lucie County, Florida. The material was identified as gypsum (CaSO/sub 4/ /times/ 2H/sub 2/O) using x-ray diffraction and infrared spectra. Photomicrography and scanning electron microscopy revealed that gypsum accumulated both in old root channels and within citrus root tissue of the Btg horizon. The subsurface horizons had elevated sulfate levels, a low initial pH, a drop (0.5 unit) in pH upon air-drying. Electrical conductivity paralleled the concentration of water-soluble sulfate. High levels of calcium and sulfate occurred for horizons above the water table. This accumulation is attributed to groundwater bearing these ions and subsequently discharging them to the overlying soil. Dead citrus roots appear to act as wicks to aid water transfer from lower to higher horizons. The roots and their empty ...
1988-02-01
Propanil-induced methemoglobinemia and hemoglobin binding in the rat
International Nuclear Information System (INIS)
Administration of [ring-U-14C]propanil (3,4-dichloropropionanilide) to male Sprague-Dawley rats (30, 100, and 300 mg/kg, ip) increased the formation of methemoglobin at the two highest doses. Following a propanil dose of 100 mg/kg, methemoglobin formation attained a maximum level of 5% by 1.5 hr and declined to normal levels (approximately 2.5%) by 12 hr. Hemoglobin binding attained a maximum level of 50 pmol/mg protein by 12 hr, and remained constant for 24 hr. Following a propanil dose of 300 mg/kg, methemoglobin formation attained a maximum level of 24% by 4.5 hr, and declined to a level of 5% by 24 hr. Hemoglobin binding attained a maximum level of 425 pmol/mg protein by 12 hr, and remained constant for 24 hr. Hemoglobin binding was also detected at the lowest propanil dose (10 pmol/mg protein) even though methemoglobin formation was not observed. HPLC ...
Program plan for development of underground hydroelectric pumped storage technology
The Underground Hydroelectric Pumped Storage (UHPS) Program Plan describes in detail the planned activities and expected accomplishments in the conduct of UHPS technology development and validation envisioned in the 1976 to 1990 time frame. This document describes the program objectives, implementation strategy, and management methodology. The concept of underground hydroelectric pumped storage is fully directed to application in the electric utility industry. This technology involves using electrical energy generated by base-load plants during off-peak load periods to drive a high-head pump/turbine which pumps water from a lower reservoir to a substantially elevated (upper) reservoir corresponding to a head of 1000 m or so. The upper reservoir is at ground level and the lower reservoir is below ground. Then, during peak-load periods, water in the upper reservoir is allowed to flow to the lower reservoir which, in turn, ...
1976-03-01
Energy Technology Data Exchange (ETDEWEB)
A numerical model of multiphase air-water flow and contaminant transport in the unsaturated zone is presented. The multiphase flow equations are solved using the two-pressure, mixed form of the equations with a modified Picard linearization of the equations and a finite element spatial approximation. A volatile contaminant is assumed to be transported in either phase, or in both phases simultaneously. The contaminant partitions between phases with an equilibrium distribution given by Henry`s Law or via kinetic mass transfer. The transport equations are solved using a Galerkin finite element method with reduced integration to lump the resultant matrices. The numerical model is applied to published experimental studies to examine the behavior of the air phase and associated contaminant movement under water infiltration. The model is also used to evaluate a hypothetical design for a low-level radioactive waste disposal ...
1995-05-01
The present study investigated sex differences and the effect of a high level of estradiol in the female meadow vole on performance in the forced swim test (FST) and the Morris water maze in meadow voles. Female meadow voles were ovariectomized (OVX) and administered either vehicle (sesame oil) or estradiol for 2 days prior to performing the FST. Four days following the FST, all animals were run in the Morris water maze. Results indicated that estradiol-injected female meadow voles showed more 'depressive-like' behaviors in the FST (greater time spent immobile and less time spent swimming) than vehicle-treated female or male meadow voles. In addition, estradiol-treated females had impaired performance (greater latencies and distance swam to reach the hidden platform) than both vehicle-treated female and male meadow voles, consistent with previous data. Despite the fact that estradiol administration increased ...
2002-11-01
Climate change impacts and adaptation : a Canadian perspective
International Nuclear Information System (INIS)
This book summarizes the research that has been conducted in Canada over the past five years on the issue of climate change impacts on key sectors such as water resources, agriculture, forestry, fisheries, coastal zones, transportation, and human health and well-being. The book refers to the growing evidence that climate change is occurring. The Intergovernmental Panel on Climate Change (IPCC) believes that these changes have already contributed to increases in annual precipitation, cloud cover and extreme temperatures over the last 50 years. It suggests that it in order to develop an effective strategy for adaptation, it is necessary to understand the vulnerability of each sector to climate change in terms of the nature of climate change, the climatic sensitivity of the region being considered, and the capacity to adapt to the changes. Adaptation will require a reduction in greenhouse gas emissions in order to lower the rate of climate change. Problems associated ...
Study of building materials impregnation processes by quasi-real-time neutron radiography
International Nuclear Information System (INIS)
Neutron radiography (NR) is a useful non-destructive method for determination of hydrogen content in various building and technical materials. Monitoring of transport processes of moisture and hydrogenous liquids in porous building materials is enabled by fast, quasi-real-time NR methods based on novel imaging plate neutron detectors (IP-NDs). Hydrogen content in the samples is determined by quantitative analysis of measured profiles of neutron attenuation in the samples. Detailed description of quantitative NR method is presented by the authors in another accompanying contribution at this conference. Deterioration of building materials is originated by different processes that all require presence of water therefore it is essential to limit or prevent the transport of water through the porous material. In this presentation, results of a study of clay brick impregnation by silicone based hydrophobic agents will be ...
1999-11-03
Renewable energy forecasts for solar applications : an Environment Canada perspective
Energy Technology Data Exchange (ETDEWEB)
The Meteorological Service of Canada has made weather datasets available in real-time on the Internet, for use by those with an interest in solar applications. Ensemble weather models can be used to produce medium range forecasts of weather events and to predict the likely available kilowatt-hours (kWhrs) of solar energy. As such, solar sites can maximize their harvest and use of solar energy. This presentation highlighted several different types of renewable energy forecasts obtained from weather models, including forecasts of expected kWhrs from solar panels and wind turbines, daily forecasts of expected solar heated water volumes and forecasts of water collection potential from impending precipitation events. The value of renewable energy forecasts in helping the solar energy sector monitor daily energy loads as well as daily and weekly solar energy supply was emphasized. It was suggested that renewable energy forecasts ...
2006-07-01
NICE3: Dyebath reuse in carpet manufacturing
Energy Technology Data Exchange (ETDEWEB)
Fact sheet on an analysis system for dyebath processes in the carpet manufacturing industry written for the NICE3 Program. The Georgia Institute of Technology (G.I.T.) has developed an effective automated dyebath analysis and reuse system that improves the energy, environmental, and economic performance of dyehouse batch operations. The new system enables dyeing solutions to be accurately monitored and adjusted for reuse. According to industry estimates, 160 pounds of water are used to produce each pound of textile product. The current wasteful batch dyeing process requires all water and residual chemicals, as well as the energy required to heat the mixture for dyeing, to be dumped after one application. Spent dyebaths can only be reused after they are sampled, analyzed, and reconstituted, a process requiring labor and expertise that are unavailable in the dyehouses. Therefore, successful commercial reuse depends on an ...
1999-09-29
Fifteenmile Basin habitat enhancement project : annual report FY 1990.; ANNUAL
International Nuclear Information System (INIS)
The goal of the Fifteenmile Creek Habitat Improvement project is to improve wild winter steelhead habitat in the Fifteenmile Creek Basin. This goal was addressed under the Columbia River Basin Fish and Wildlife Program, Measure 703 (c) (1) - Action Item 4.2. Construction of fish habitat structures was completed on approximately 3.5 miles of Eightmile Creek and on approximately 8.5 miles of Fifteenmile Creek. A total of 15,435 yds of rock was placed to improve rearing and spawning habitat, and to improve water quality and reduce siltation. Riparian protection fencing was completed on 1.8 miles of Dry Creek, approximately 1.75 miles on Eightmile Creek, and 4.75 miles on Fifteenmile Creek. Approximately 10 miles of stream will receive protection from the 8 miles of new fencing installed and 6.5 miles of abandoned fence repaired. Irrigation withdrawal screens were installed at six irrigation pump withdrawals. These screens functioned satisfactorily during the ...
Black tide from the Bay of Campeche. [June 3, 1976 blowout
Energy Technology Data Exchange (ETDEWEB)
The ruptured offshore oil well 80 miles from Mexican town of Ciudad del Carmen, which poured 8000 barrels of light oil a day into the Gulf of Mexico, provided marine scientists with the opportunity to monitor the spill and see what happens to petroleum hydrocarbons in sea water. Scientists followed changes in viscosity, surface tension, and buoyancy of individual oil globs as they moved through the water and interacted with the surface slick. Using gas chromatography and mass spectroscopy, chemists are gaining an understanding of the unique characteristics of the oil. Computer-generated models projected the slick's movement in the Gulf in response to wind and wave pressures, but the sophisticated system did not give an accurate daily prediction. Immediate damage to fish, turtles, and sea birds was documented by tagging. Long-term effects will take longer to ascertain since 25 years is generally required to flush ...
1980-01-24
Energy Technology Data Exchange (ETDEWEB)
During this project we experimentally evaluated the below-ground biomass and carbon allocation and partitioning of four different fast- and slow-growing families of loblolly pine located in Scotland County, NC, in an effort to increase the long-term performance of the crop. The trees were subjected to optimal nutrition and control since planting in 1993. Destructive harvests in 1998 and 2000 were used for whole?plant biomass estimates and to identify possible family differences in carbon acquisition (photosynthesis) and water use efficiency. At regular intervals throughout each year we sampled tissues for carbohydrate analyses to assess differences in whole-tree carbon storage. Mini rhizotron observation tubes were installed to monitor root system production and turnover. Stable isotope analysis was used to examine possible functional differences in water and nutrient acquisition of root systems between the various ...
2001-03-01
Energy Technology Data Exchange (ETDEWEB)
A beta microprobe was successfully applied to monitor arterial input function for quantification of regional cerebral blood flow (rCBF) in the monkey brain with {sup 15}O-water and positron emission tomography (PET). The sensitivity of the probe was approximately 0.83 to 1.67 cps/kBq/ml depending on the studies. A preliminary study was performed to find a suitable use and to evaluate the performance of the system and data analysis procedure. The results showed that dispersion correction of measured input function was unnecessary if microprobes were connected directly to the arterial catheter. Then multiple CBF measurements were done in three monkeys under anesthesia. Identical regions of interest were placed with the aid of magnetic resonance imaging (MRI) of each monkey and rCBF values were estimated. Estimated rCBFs were reproducible for several measurements. The mean CBF value for a pentobarbital anesthetized monkey was 46.0 ml/min/100 g ...
1998-02-01
A framework for assessing relative risks associated with multiple stressors in Port Valdez, Alaska
Energy Technology Data Exchange (ETDEWEB)
The purpose of this assessment is to develop a versatile process that will provide a mechanism for evaluating both present and future risks to this environment. Much of the regulatory and environmental interest in the port has centered around a Ballast Water Treatment facility that treats and discharges up to 30 mgd of oily ballast water brought in by crude oil tankers. However, six point discharges and other potential sources of pollution exist in the area. The authors have delineated eleven subareas in the port in order to identify the potential anthropogenic stressors, as well as the receptors that could be exposed to these stressors. Potential effects were then characterized for each exposure. Each component is ranked and integrated, resulting in a relative risk estimate in each subarea. Both the discernible risks, based on available data, and the data gaps are presented. Uncertainty is expressed as a range of high and low risk associated ...
1995-12-31
/sup 252/Cf-source-driven neutron noise analysis method
Energy Technology Data Exchange (ETDEWEB)
The /sup 252/Cf-source-driven neutron noise analysis method has been tested in a wide variety of experiments that have indicated the broad range of applicability of the method. The neutron multiplication factor k/sub eff/ has been satisfactorily detemined for a variety of materials including uranium metal, light water reactor fuel pins, fissile solutions, fuel plates in water, and interacting cylinders. For a uranyl nitrate solution tank which is typical of a fuel processing or reprocessing plant, the k/sub eff/ values were satisfactorily determined for values between 0.92 and 0.5 using a simple point kinetics interpretation of the experimental data. The short measurement times, in several cases as low as 1 min, have shown that the development of this method can lead to a practical subcriticality monitor for many in-plant applications. The further development of the method will require experiments oriented toward particular ...
1985-01-01
British Library Electronic Table of Contents (United Kingdom)
Biomarkers are biometric measurements that provide critical quantitative information about the biological condition of the animal or individual being tested. In drug safety studies, established toxicity biomarkers are used along with other conventional study data to determine dose-limiting organ toxicity, and to define species sensitivity for new chemical entities intended for possible use as human medicines. A continuing goal of drug safety scientists in the pharmaceutical industry is to discover and develop better trans-species biomarkers that can be used to determine target organ toxicities for preclinical species in short-term studies at dose levels that are some multiple of the intended human dose and again later in full development for monitoring clinical trials at lower therapeutic ...
2010-01-01
Targeted drug delivery under MRI guidance
British Library Electronic Table of Contents (United Kingdom)
The main goal of local drug delivery is to increase the concentration of a specific therapeutic agent in a target tissue with minimal nontarget distribution. Compared to systemic therapy, local drug delivery provides a high level of therapeutic efficacy with minimal systemic effects. The current primary imaging modality for drug delivery has been x-ray angiography, but it has major limitations including anatomical ambiguity and inability to visualize the targeted tissues. Due to these inherent problems, MR guidance has been explored as an alternative imaging modality for guiding and monitoring of drug therapy. Recently, interventional MR (XMR) systems have been implemented that have both dual x-ray and MRI capabilities in a single suite and allow for real-time interventional procedures to ...
2008-01-01
Steatohepatite non alcoolique chez une adolescente obese : une biopsie hepatique discutable
British Library Electronic Table of Contents (United Kingdom)
The growing epidemic of juvenile obesity has prompted pediatricians to investigate obesity-related conditions in obese teenagers. We report a clinical case of severe hepatic fibrosis in an adolescent with severe and recent obesity. Because of elevated serum aminotransferase levels, abnormal hepatic ultrasonography and insulin resistance (impaired glucose tolerance), we suspected nonalcoholic steatohepatitis (NASH). Disease activity and fibrosis were confirmed on liver biopsy. Considering the risk of progression toward cirrhosis and its complications, and the pathological liver lesions, we started long-term medical monitoring and drug therapy to control weight loss. At present, although biopsy is the only validated way to establish the diagnosis of NASH, there is no consensus on its indicat...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
The purpose of this study was to evaluate the toxicological effects of feeding the oils of Calophyllum inophyllum, Pentaclethra macrophylla and Terminalia catappa to rats. The effects on physical appearance, feed intake, weight gain, plasma and tissue cholesterol and triacyglycerol levels in rats with 5% of the oils in normal rat feed were determined. Weekly monitoring of the rats showed good physical appearance and steady weight gain, with no mortality recorded for the period of the study. Haematological analysis of the rats indicated that they were not anaemic. Histopathotogical examination of the sections of the heart, liver, kidney and spleen revealed moderate (T. catappa oil) to severe fatty change and necrosis in the liver. Glomerulonephrotic changes in the kidneys of rats fed with T...
2008-01-01
Short-term radon measurements in the workplace
Energy Technology Data Exchange (ETDEWEB)
A novel envelope-type radon monitor has been used for short-term (as little as 1 week) radon concentration measurements in a workplace environment. The commercially available LR-115 type II damage track detector was used in this study and the chemically etched sheets were spark counted. The measurements were made over a period of 1 year in a workplace consisting of three adjacent rooms situated in the lower ground level of multistorey office building in Rome, Italy. The variations of the radon concentration are from [approx] 20 to [approx] 300 Bq m[sup -3] with averages of 130,81 and 73 Bq m[sup -3] for the three different rooms resulting in annual doses of [approx] 3.8, [approx] 2.4 and [approx] 2.2 mSv, respectively. (author) 2 figs., 9 refs.
1992-01-01
Reducing energy costs of plastics processing
Energy Technology Data Exchange (ETDEWEB)
Ways of reducing energy consumption in plastics processing are examined. Examples are given which illustrate how the awareness of everyone in the company to energy saving is essential with particular reference to switching arrangements to ensure such things as lights, machinery, compressed air systems are switched off when not needed or run at a lower level where appropriate. An understanding of the various elements of the electricity bill can inform a company`s planning of its operations to take advantage of lower tariffs. Machinery selection both with regard to efficiency of processing, quality of engineering and appropriate size can achieve significant savings and attention to maintenance is important. Fundamental to all aspects of energy saving is the monitoring of energy usage to identify where savings can be made and to evaluate the effectiveness of any measures taken. (UK)
1995-02-01
Energy Technology Data Exchange (ETDEWEB)
This study has been carried out in the framework of a collaboration between the laboratory of processes automation (LAP, Caen (France)), and Air Com, a monitoring network for the prevention of atmospheric pollution in Basse-Normandie. It aims at obtaining a medium and long term forecast of the ozone level above the Caen city. The expected goal is to foresee the pollution peaks exceeding the warning thresholds, but the rareness of such events make them more difficult to predict. In order to solve this kind of problem, a neural modeling method combined with a noise injection technique has been implemented in order to obtain a sufficiently performing model over the whole domain of operation. (J.S.)
2001-07-01
British Library Electronic Table of Contents (United Kingdom)
Internet is providing essential communication between an infinite number of people and is being increasingly used as a tool for commerce. At the same time, security is becoming a tremendously important issue to deal with. Different network security solutions exist and contribute to enhanced security. From these solutions, Intrusion detection systems (IDS) have become one of the most common countermeasures for monitoring safety in computer systems and networks. The purpose of IDSs is distinguishing between intruders and normal users. However, IDSs report a massive number of isolated alerts. These isolated alerts represent low-level security-related events. Many of these isolated alerts are logically involved in a single multi-stage intrusion incident and a security officer often wants to an...
2011-01-01
Light from polymers - prediction of service life
Energy Technology Data Exchange (ETDEWEB)
Stress chemiluminescence (SCL) is a novel technique for monitoring aging reactions of polymeric materials under stress. A special apparatus for detecting the chemiluminescence of solid polymers has been designed and built. There is a correlation between an enhanced chemiluminescence signal at low levels of applied stress and subsequent premature mechanical failure of samples of tetraglycidyl-4,4'-methylenedianiline (TGMDA) cured with 4,4'-diaminodiphenyl sulfone (DDS) the most commonly used epoxy in high performance fiber composites. Chemiluminescence data from silicone cushions is used to validate accelerated aging tests and preliminary results from Kevlar fibers are reported. The technique will be extended to other polymeric materials including fiber composites. 22 references, 7 figures, 1 table.
1984-01-01
Imaging pharmacodynamics in oncology. The potential significance of 'flares'
International Nuclear Information System (INIS)
The clinical use of "1"8F-fluorodeoxyglucose (FDG) positron emission tomography in monitoring anticancer treatment is expanding. At the same time a number of radiotracers aiming to image different aspects of tumour biology such as proliferation and apoptosis are being developed. However, the factors determining changes of radiotracer uptake parameters in response to treatment are not well understood. In many cases, cellularity may be the primary determinant of changes of FDG uptake and may confound the interpretation of metabolic changes. Early imaging assessments have in some cases showed transient increases of uptake parameters, commonly termed 'flares', which are likely to be unaffected by cellularity and directly reflect pharmacodynamics at a cellular level. In this review a number of settings where molecular imaging 'flares' have been described are discussed. Such changes may often be clinically informative and warrant careful study as ...
2010-04-01
British Library Electronic Table of Contents (United Kingdom)
In this paper we demonstrate the capabilities of our ArcGIS-based software development that includes an adapted database system and a GIS tool for storage, combined analysis and visualization of leveling data and interferometric synthetic aperture radar (SAR) deformation measurements. Preprocessed remote sensing image data are stored with metadata that include all processing routines and parameters. This allows reproduction and traceability of all processing steps. Deformation monitoring is supported through data searching and selection based on a variety of criteria. A methods toolbox allows spatio-temporal analyses for points, lines and areas (e.g. subsidence basins) in a graphical manner.
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
Abstract In response to growing consumer concerns, developed-country governments have reduced permissible pesticide residue levels in food. Many food retailers have developed even more stringent private food safety protocols relating to pesticide use, storage and disposal and passed them on to their suppliers. Exporters in developing countries enforce these developed-country pesticide standards (DC-PS) by subjecting farmers to close monitoring. This study explores the effects of enforcing compliance with DC-PS on smallholder farmers' pesticide-related health costs. Results suggest that enforcing DC-PS encourages farmers to use protection that lowers pesticide-induced morbidity, hence reducing farmers' health costs from pesticide exposure. The study concludes that there are health benefits ...
2010-01-01
Experimental modelling of thermal consolidation effects around a high level waste repository
International Nuclear Information System (INIS)
This report summarizes the results of a research programme which involves the development of a laboratory experimental facility for the simulation and study of hydro-thermo-mechanical processes in saturated geomaterials with low permeability. The experimentation involves a synthetic cement based porous material made of cement grout which possesses permeabilities in the range of dense unfractured sandstones or shale. Specially manufactured pore-pressure transducers were installed within the cylindrical block at locations adjacent to a plane free boundary. The block was saturated with the periodic application of a vacuum. In its saturated state the plane boundary of the block was subjected to heating via a circular heater the temperature of which was maintained constant. The resulting pore pressure generation along with temperature at these locations was monitored continuously. The results of a series of experiments are documented and further extensions to the ...
British Library Electronic Table of Contents (United Kingdom)
The homogeneity of a helium dielectric barrier discharge, working at atmospheric pressure and containing oxygen as contaminant, is assessed by mapping the spatial distribution of oxygen metastable atoms in relation to the uniformity of surface properties. Tunable diode laser absorption spectroscopy is used to monitor the time evolution of the absorption coefficient corresponding to the oxygen metastable atoms on the 35S2 level, as a function of the laser absorbing path, whereas bi-dimensional Abel transform is used to obtain local information on the space distribution of the metastable atoms in the discharge. The radial distribution of the surface properties is investigated using atomic force microscopy, contact angle measurement and X-ray photoelectron spectroscopy. The results show that ...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
The atmospheric processing by ozone of peptide-containing mixed particles was investigated as proxies for biogenic and sea spray primary organic aerosol. Reactions were performed in a flow reactor and particle composition was monitored by photoelectron resonance capture ionization aerosol mass spectrometry. Mixed particles containing dipeptides in a saturated organic matrix of stearic and palmitic acids showed no reaction under ozonolysis at exposure levels of 2.5???10?4?atm s O3. However reactions of mixed particles of a dipeptide (Leu-Leu) in an unsaturated matrix (oleic acid) under the same conditions resulted in a rapid loss of the peptide ion signal, as well as the carrier matrix, and appearance of a number of ion signals corresponding to secondary products. High molecular weight imid...
2009-01-01
International Nuclear Information System (INIS)
Presented here is the calculation of the diffusion of radionuclides from the Daya Bay Nuclear Power Plant under normal operation on the basis of Gaussian model. The model is modified partially considering practical situation, and monitoring meteorological data are adopted. By using the AIRDOS-EPA computer code, the average annual ground-level concentration distribution of radionuclides from Daya Bay Nuclear Power Plant in 2001 was obtained, the atmospheric dispersion factor and ground deposition rate were also acquired. These calculated results can provide information for understanding the effect on radiation environment due to Daya Bay Nuclear Power Plant under normal operation. (authors)
2007-11-01
A radon anomaly in soil gas at Cazzaso, NE Italy, as a precursor of an M_L = 5.1 earthquake
International Nuclear Information System (INIS)
At Cazzaso (Friuli) in northeast Italy, radon ("2"2"2Rn) activity concentration in soil gas in a borehole at a depth of 80 cm has been monitored continuously (at a frequency of once an hour) since May 2004, using a Barasol probe (Algade, France). In addition, environmental parameters (air and soil temperature, barometric pressure) have been recorded. The results have been evaluated and the relationship between radon levels and seismic activity is discussed. Correlation between radon concentration and barometric pressure has been observed. Preliminary results have shown a distinct radon anomaly prior to some earthquakes. (authors)
2009-05-10
Corrosion probes for fireside monitoring in coal-fired boilers
Energy Technology Data Exchange (ETDEWEB)
Corrosion probes are being developed and combined with an existing measurement technology to provide a tool for assessing the extent of corrosion of metallic materials on the fireside in coal-fired boilers. The successful development of this technology will provide power plant operators the ability to (1) accurately monitor metal loss in critical regions of the boiler, such as waterwalls, superheaters, and reheaters; and (2) use corrosion rates as process variables. In the former, corrosion data could be used to schedule maintenance periods and in the later, processes can be altered to decrease corrosion rates. The research approach involves laboratory research in simulated environments that will lead to field tests of corrosion probes in coal-fired boilers. Laboratory research has already shown that electrochemically-measured corrosion rates for ash-covered metals are similar to actual mass loss corrosion rates. Electrochemical tests conducted using a potentiostat ...
2005-01-01
Ultra-high pressure water jet: Baseline report
International Nuclear Information System (INIS)
The ultra-high pressure waterjet technology was being evaluated at Florida International University (FIU) as a baseline technology. In conjunction with FIU's evaluation of efficiency and cost, this report covers the evaluation conducted for safety and health issues. It is a commercially available technology and has been used for various projects at locations throughout the country. The ultra-high pressure waterjet technology acts as a cutting tool for the removal of surface substrates. The Husky trademark pump feeds water to a lance that directs the high pressure water at the surface to be removed. The safety and health evaluation during the testing demonstration focused on two main areas of exposure. These were dust and noise. The dust exposure was found to be minimal, which would be expected due to the wet environment inherent in the technology, but noise exposure was at a significant level. Further testing for noise is ...
1997-07-01
Energy Technology Data Exchange (ETDEWEB)
High energy radiation was studied as a means for destroying hazardous organic chemical wastes. Tests were conducted at bench scale with a {sup 60}Co source, and at full scale (387 l/min) with a 1.5 MV electron beam source. Bench scale tests for both benzene and phenol included 32 permutations of water quality factors. For some water qualities, as much as 99.99% of benzene or 90% of phenol were removed by 775 krads of {sup 60}Co irradiation. Full scale testing for destruction of benzene in a simulated waste-water mix showed loss of 97% of benzene following an 800 krad dose and 88% following a 500 krad dose. At these loss rates, approximately 5 Mrad of electron beam irradiation is required to reduce concentrations from 100 g/l to drinking water quality (5 {mu}g/l). Since many waste streams are also inhabited by bacterial populations which may affect filtering operations, the effect of irradiation on those ...
1993-08-01
Remediation process technology for ground water
Energy Technology Data Exchange (ETDEWEB)
The operation of industrial facilities has generally resulted in contamination of the surrounding soils and ground water. A variety of methods have been proposed for the remediation of contaminated sites. This paper presents new process technology that is capable of performing treatment on ground water or soil washing leachates. The process is targeted to treat low levels of radioactivity, organics and heavy metals present in the aqueous solutions, to be easily transported and provide simple operation on-site and provide an effluent that meets the specified discharge quality. The purification process involves sequential chemical treatment and filtration. The paper will describe the development of the technology and review the current progress in its use to remediate contaminated sites at Chalk River. The application of the process technology has demonstrated that the ambitious goal of setting the effluent targets to meet ...
1993-12-31
Remediation process technology for ground water
International Nuclear Information System (INIS)
The operation of industrial facilities has generally resulted in contamination of the surrounding soils and ground water. A variety of methods have been proposed for the remediation of contaminated sites. This paper presents new process technology that is capable of performing treatment on ground water or soil washing leachates. The process is targeted to treat low levels of radioactivity, organics and heavy metals present in the aqueous solutions, to be easily transported and provide simple operation on-site and provide an effluent that meets the specified discharge quality. The purification process involves sequential chemical treatment and filtration. The paper will describe the development of the technology and review the current progress in its use to remediate contaminated sites at Chalk River. The application of the process technology has demonstrated that the ambitious goal of setting the effluent targets to meet ...
1993-09-05
Preliminary study of the effect of pumped-storage plant operation on zooplankton
Energy Technology Data Exchange (ETDEWEB)
The hydromechanical effect of hydroelectric stations on zooplankton is customarily regarded as a constantly acting and comparatively harmless factor, since its destruction is inevitable when water masses are passed through hydroelectric stations, but its capacity for restoration is high (i.e., destruction of the zooplankton of the forebay is compensated by its production in the after bay). It is not known how correct such an opinion is, or what is the true balance of losses and reproduction of zooplankton in the forebays and after bays of hydroelectric stations. However, hydroelectric plants of a new type, pumped-storage plants, have been constructed in recent years and others are planned for the Dnieper reservoirs. The operational principle and purpose of these plants is that they employ special vertical turbine-electric pumps that pump water at night from the reservoirs into pumped-storage facilities at high levels, and ...
1980-01-01
Microbial indicators of environmental water pollution. Mizu kankyo ni okeru biseibutsu shihyo
Energy Technology Data Exchange (ETDEWEB)
Microbial indicators in the environmental water are categorized as follows. 1. Index for pathogenic microbial contamination, especially enteric canal based ones. 2. Index for the ordinary microbial contamination. 3. Index for nutritive assessment. 4. Index for the treating effect of final effluent discharged into an environmental water. 5. Index for distinction of of the contamination source. Above 1 and 2'' are among the indices which cannot be replaced by other physico-chemical substances or indices. Up to the present time, 1'' is assessed by a coliform group and 2'' by the bacteria. Recently, however, the status on the microbial contamination of the environmental water is changing, thus urging the reexamination of the assessment systems. This report describes the following items. Characteristics and the elements of the indices (enteric canal based pathogenic microbial ...
1990-08-10
Energy Technology Data Exchange (ETDEWEB)
Soil contamination by liquid organic pollutants represents a serious threat to phreatic ground water. These organic liquids get into the ground and migrate through the porous medium until they finally reach the aquifer. After a critical study of the literature, we listed various existing multiple displacements under three-phase conditions of a disconnected polluting phase that may or not spread over water. The aim of this thesis is to model (at pore scale level) and integrate in the pore network model the various flows that occur when three phases (gas, pollutant and air) are present in a porous medium. The porous medium is supposed completely water-wet. The polluting phase may be connected or not, and the spreading coefficient of the pollutant over water may either be positive or negative. The goal of our study is to obtain macroscopic parameters such as relative permeabilities and ...
2006-10-15
Evaluation of a solid hydrophone cable
Energy Technology Data Exchange (ETDEWEB)
In marine seismic exploration, an approximately two-mile long hydrophone cable is towed behind the ship. The commonly employed cable consists of a kerosene-filled hose enclosing hydrophones, electrical wires, and steel ropes. The kerosene provides buoyancy while the steel ropes are for structural support. For deep-water operations, the cable is pulled through the water at a depth of 20-40 feet. For shallow water, a bottom reference configuration is used and the cable is dragged. This paper presents a comparison of electroacoustic properties between a newly designed, buoyant solid cable and those of the conventional kerosene-filled hose. The emphasis is on drag cable operations. Cable maintenance is a major problem. Jacket cuts occur because of improper handling or collisions with other ships, subsea structures, and debris. Kerosene leakage causes buoyancy loss and the need for immediate replacement. Salt ...
1982-07-01
International Nuclear Information System (INIS)
From June to September 2004 a water research was carried out in six stations that are located at the following microbasins: La Laucha (S1), La Lejia (S2, S3 and S6) and La Rastrojera (S4 and S5). Those microbasins are localized at the Durania municipality in Norte de Santander Department. This study was carried out in order to evaluate water quality at the microbasins above mentioned using macroinvertebrates as bioindicators. For physical, chemical and microbiological parameters a sample was taken at each station. The results were correlated with biologic parameters and it may be concluded that the station 5 closer to the town of Durania is the most polluted by organic matter and that those stations that belong to the ritral zone are less contaminated. The final result showed that the stations 1. 2. 3. 4 and 6 have conditions that can be classified as very clear to clear water and station 5 presents high contamination ...
2008-06-01
Emergency reactor core cooling device
International Nuclear Information System (INIS)
The device of the present invention improves reactor safety by suppressing lowering of water level in a shroud which surrounds a reactor core, even upon occurrence of rupture of pipelines in an emergency reactor core cooling system in a recycling pump-incorporated type reactor. Namely, an opening of each of cooling systems which forms the emergency reactor core cooling device in a reactor pressure vessel is disposed above the upper end of the reactor core. Further, it also comprises an independent high pressure water injection system, gravitational dropping type water injection system and an automatic depressurization system. With such a constitution, even if rupture of pipelines in the system should be assumed, coolants never flow directly from the shroud which surrounds the reactor core. In addition, there are no pipelines to be ruptured below the upper end of the reactor core with respect to the ...
1993-03-16
Diesel engine experiments with oxygen enrichment, water addition and lower-grade fuel
Energy Technology Data Exchange (ETDEWEB)
The concept of oxygen enriched air applied to reciprocating engines is getting renewed attention in the context of the progress made in the enrichment methods and the tougher emissions regulations imposed on diesel and gasoline engines. An experimental project was completed in which a direct injection diesel engine was tested with intake oxygen levels of 21% -- 35%. Since an earlier study indicated that it is necessary to use a cheaper fuel to make the concept economically attractive, a less refined fuel was included in the test series. Since a major objection to the use of oxygen enriched combustion air had been the increase in NO{sub x} emissions, a method must be found to reduce NO{sub x}. Introduction of water into the engine combustion process was included in the tests for this purpose. Fuel emulsification with water was the means used here even though other methods could also be used. The teat data indicated a large ...
1990-01-01
FEBEX II Project Final report on thermo-hydro-mechanical laboratory tests
International Nuclear Information System (INIS)
The results of the thermo-hydro-mechanical (THM) study of the FEBEX bentonite performed during FEBEX II are presented. The laboratory test program continued in part with the works carried out during FEBEX I, particularly in activities related to tests aimed to the calibration of the models, the acquisition of parameters by back-analysis and the improvement of the knowledge on the behaviour of expansive clays. But the program has also included tests on new areas: investigations about the influence of the microstructure changes in bentonite, of temperature and of the solute concentration on the behaviour of clay. Besides, several tests were proposed in order to understand the unexpected behaviour observed in the mock-up test, towards the end of year 2. Temperature effects on water retention curves in confined and unconfined conditions were determined, and swelling pressure, hydraulic conductivity and swelling and consolidation strains as a function of temperature ...
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study was to evaluate the ability to enhance distribution of eelgrass (Zostera marina) in the Columbia River Estuary to serve as refuge and feeding habitat for juvenile salmon, Dungeness crab, and other fish and wildlife. We strongly suspected that limited eelgrass seed dispersal has resulted in the present distribution of eelgrass meadows, and that there are other suitable places for eelgrass to survive and form functional meadows. Funded as part of the Bonneville Power Administration's call for Innovative Projects, we initiated a multistage study in 2008 that combined modeling, remote sensing, and field experimentation to: (1) Spatially predict habitat quality for eelgrass; (2) Conduct experimental plantings; and (3) Evaluate restoration potential. Baseline in-situ measurements and remote satellite observations were acquired for locations in the Lower Columbia River Estuary (LCRE) to determine ambient habitat conditions. These were used to create a ...
2009-09-08
Energy Technology Data Exchange (ETDEWEB)
The use and application of remote sensing data for monitoring the environmental impacts of open cast lignite mining in Eastern Germany is described. This investigation is based on the digital analysis of several Landsat-TM and ERS-1 data sets acquired from 1989 to 1994. The characteristics of the imagery enable quantitative analysis of different open cast mine features, such as waste, water bodies, change of land use, reclamation processes and estimation of vegetation cover in the affected areas. On the basis of the Maximum Likelihood Classification of Landsat Thematic Mapper (TM) data the open cast mining areas were separated into bare open cast areas and areas of less and dense vegetation. The bare open cast areas were classified with respect to type of different sediments and the vegetation was seperated into different classes according to the age of the vegetation and the density cover. Apart from these, water bodies ...
1998-08-01
Energy Technology Data Exchange (ETDEWEB)
The advantages offered by green roofs range from improvement in architectural and landscape aesthetics to reductions in building energy costs. Seattle Public Utilities (SPU) is encouraging sustainable community development through new policies and regulations that promote green roof installation on public and commercial rooftops in Seattle's urban center. An understanding of climate-specific green roof performance is required in order to develop an accurate representation of the stormwater benefits of green roofs. This paper explored the relative importance of green roofs in storm water management and low impact development (LID) in various areas of Seattle. It also examined the relative effectiveness and applicability of green roofs under various conditions and in various parts of the city compared to other LID strategies such as Seattle's natural drainage systems (NDS) designs, swales and ponds, rain gardens, rainwater harvesting, and porous ...
2007-07-01
Energy Technology Data Exchange (ETDEWEB)
A fast and simple flow-through optosensor was designed and characterized for the direct screening of four tetracycline (TCC) antibiotics (tetracycline, oxytetracycline, chlortetracycline and doxycycline) in water and bovine milk samples. The proposed optosensor provides rapid binary yes/no overall responses, being appropriate for the screening of this family of antibiotics above or below a pre-set concentration threshold. The experimental set-up is based on a flow-injection manifold coupled on-line to a phosphorescence detector. Aliquots of the samples are pretreated with Eu(III) to form room temperature phosphorescent metal chelates and injected in the flow manifold. Those chelates are then on-line retained on a conventional flow-cell (packed with polymeric Amberlite XAD-4 particles) which is placed inside the cell holder of the phosphorimeter. After the emission is registered, the antibiotic-metal complexes are eluted from the packed resin with 1 M HCl (for milk ...
2007-04-18
Energy Technology Data Exchange (ETDEWEB)
The carbon isotope profiles of shallow-marine carbonates from the Barremian-Aptian Kharaib and Shuaiba formations of the Arabian Gulf region range between 0.5 and 7{per_thousand} {delta}{sup 13}C PDB (Peedee belemnite). Systematic variations can be correlated with isotope profiles reported from Tethyan pelagic limestone sequences. The detailed correspondence between the isotopic signature of the relatively well-dated pelagic limestones and the poorly dated shallow-water limestones from the Arabian Gulf region suggests that global marine carbon isotope changes apparently affected deep-sea and shallow-water carbonate sediments similarly and at a similar time resolution. Although oxygen isotopes have been reset during diagenesis, carbon isotopes appear to have maintained their primary marine signature through time. No evidence has been found to connect carbon isotope trends to subaerial exposure or later meteoric diagenesis. In combination with ...
1996-05-01
Relative correlation of Jet-REMPI monitoring with adsorption tube sampling followed by TDS-CIS-GC/MS
Energy Technology Data Exchange (ETDEWEB)
During earlier work rapid and highly sensitive Jet-REMPI (resonance-enhanced multiphoton ionization) mass spectrometry was applied for monitoring the effluent from thermal treatment of a filter dust during a de novo test under laboratory conditions. The sample, from ESP-Field 2 of an iron ore sintering plant, was already loaded with dioxins ({sigma}PCDD/F = 132 ng/g), their precursors (PCBz, PCPh) and other products of incomplete combustion. Heating filter dust in a temperature window 200-350 C under a flow of air results in further formation of these pollutants. As described elsewhere, on-line detection was mostly carried out using a non-selective ionization mode, to measure a wide range of compounds simultaneously. The changes of output suggest that the reaction products increase in chlorination level with time. Another explanation is that higherchlorinated compounds appear later as a consequence of lower volatility and stronger adsorption. ...
2004-09-15
A comparison of cathode ray tube (CRT) and computed radiography (CR) diagnosis in mammography
International Nuclear Information System (INIS)
Quantitative evaluation of CRT and CR observations in indentification of malignancy using phantom and clinical data. A breast phantom and a total of 40 patients were imaged by Fuji computed radiography (FCR). The images were interpreted twice by six radiologists both on CR film (2510 x 2000 pixels x 10 bits, 0.1 mm spatial resolution) and on a CRT monitor (1568 x 1152 pixels x 10 bits, 0.1 mm pixel size with double expansion) with image processing parameters of a toutine (RN 1.0, RE 0.2), for a calcification (RN 9.0, RE 4.0) and for a mass (RN 7.0, RE 2.0). The forty clinical cases included breast diseases with calcifications, masses, and normal breasts. Two-tailed t-test was performed to analyze interpretation of simulated microcalcifications and masses in the phantom. The receiver operating characteristic (ROC) analysis was performed to evaluate clinical cases. In all interpretation studies using both breast phantom and clinical cases, there was no significant ...
1999-11-01
Energy Technology Data Exchange (ETDEWEB)
Environmental exposure measurements are, in general, positive and may be subject to left censoring; i.e,. the measured value is less than a ''detection limit''. In occupational monitoring, strategies for assessing workplace exposures typically focus on the mean exposure level or the probability that any measurement exceeds a limit. Parametric methods used to determine acceptable levels of exposure, are often based on a two parameter lognormal distribution. The mean exposure level, an upper percentile, and the exceedance fraction are used to characterize exposure levels, and confidence limits are used to describe the uncertainty in these estimates. Statistical methods for random samples (without non-detects) from the lognormal distribution are well known for each of these situations. In this report, methods for estimating these quantities based on ...
2005-09-20
Evaluation of methods to measure surface level in waste storage tanks: Second test sequence
Energy Technology Data Exchange (ETDEWEB)
This report describes the results of a program conducted at the Pacific Northwest Laboratory (PNL) and Westinghouse Hanford Company (WHC) to identify alternative methods to measure the surface level in the waste tanks. This program examined commercially available devices for measuring the distance to a target. This is a continuation of a program started in FY93. In the first test sequence, tests were performed.on five devices to determine their applicability to measure the surface level in the waste tanks. The devices were the Enraf-Nonius{trademark} Model 872 Radar Gauge, the Enraf-Nonius{trademark} Model 854 Advanced Technology Gauge (ATG), the Stanley Tool Laser Measuring Device, the Robertshaw Inven-Tel{reg_sign} Precision Level Gauge, and the Micro Switch Model 942 Acoustic Sensor. In addition, discussions were held with several manufacturer representatives regarding other potential devices. The results of these tests ...
1993-09-01
DEFF Research Database (Denmark)
Cassava chips (cassava balls, and cassava pellets) are derived cassava products traditionally produced by farmers in sub-Saharan Africa following fermentation, and drying of fresh roots of cassava, and are widely consumed in Cameroon. Once produced, this food commodity can be stored for more than two months and contaminated by a wide array of harmful microbes. In order to assess persistence of toxigenic fungi in cassava chips, aflatoxin-producing fungi (Aspergillus flavus, Aspergillus nomius, and Aspergillus parasiticus) and aflatoxins were contrasted at regular intervals in home-stored cassava chips collected in two locations of southern Cameroon throughout a two-month monitoring period. Three hundred and forty-six isolates of aflatoxin-producing fungi were found to be associated with all samples. A. flavus contaminated more samples in both types of chips (267 isolates in 53 samples), followed by A. nomius (58 isolates in 15 samples), whereas A. parasiticus was ...
2009-01-01
Spectrophotometric determination of aluminium ion in drinking water by flow infection analysis
International Nuclear Information System (INIS)
Optimum analytical conditions of the aluminium ion were established by flow injection analysis. Eriochrome Cyanine R(ECR) dye reacts with the aluminium ion at pH 6.0 form a complex that exhibits maximum absorption at 535 nm. Reaction condition including the mixing and the reaction coil length, the concentration and the pH of the buffer solution, temperature, and injection loop volume were optimized to introduce this reaction into flow injection analysis. The results were as follows. A mixing coil length of 0.5 m and a reaction coil length of 4.0 m, the pH 6.0 and 1M of acetate buffer solution, the ECR concentration of 0.56 mM, the reaction temperature of 40 .deg. C, the injection loop volume of 300 #mu#L were chosen as optimum conditions. Under these conditions the detection limit of the aluminium ion was less than 0.05 mg/L and the repeatability was better than 1%. A sampling frequency of 24 times for an hour was achieved. Interfering ions such as F"-, HPO_4"2"-, Fe"2"+, Fe"3"+, ...
2000-10-01
Energy Technology Data Exchange (ETDEWEB)
An experimental investigation on the air/water counter-current two-phase flow in a horizontal rectangular channel connected to an inclined riser has been conducted. This test-section representing a model of the hot leg of a pressurized water reactor is mounted between two separators in a pressurized experimental vessel. The cross-section and length of the horizontal part of the test-section are (0.25 m x 0.05 m) and 2.59 m, respectively, whereas the inclination angle of the riser is 50 deg. The flow was captured by a high-speed camera in the bended region of the hot leg, delivering a detailed view of the stratified interface as well as of dispersed structures like bubbles and droplets. Countercurrent flow limitation (CCFL), or the onset of flooding, was found by analyzing the water levels measured in the separators. The counter-current flow limitation is defined as the maximum air mass flow rate at ...
2008-12-15
Experience with pressuriser for PHT pressure control in TAPP 4 reactor
International Nuclear Information System (INIS)
In a 540 MWe PHWR reactor at TAPP-4 the pressuriser has been incorporated in the PHT pressure control system to provide the necessary vapour cushion for PHT main circuit to reduce pressure variations due to transients involving swell and shrinkage. Need for the Pressuriser is due to the large inventory in PHT main circuit and relatively large heat source. The incorporation of Pressuriser is one of the modifications while upgrading from prevalent operating 220 MWe reactors to the present 540 MWe at TAPP-4. The sizing, design and selection of the 540 MWe Pressuriser has been done w.r.t swell/shrinkage requirement during normal/transient operation of the reactor. In this paper the commissioning and operating experience of the Pressuriser in conjunction with the PHT pressure control system is presented. During light water commissioning of PHT circuit some major hurdles like failure of pressuriser heaters due to faulty instrumentation were faced. Subsequently the ...
2006-11-13
Acid mine drainage and its impact in the Black Creek watershed, Virginia
International Nuclear Information System (INIS)
A one-year study was conducted to determine the impacts of acid min drainage (AMD) on the Black Creek watershed in Wise County, Virginia. Water quality, metal content of sediment and water column, soil pH, macroinvertebrate assemblages, habitat assessment and toxicity testing were used to assess the impact in the watershed. A total of 22 sites in the creek and surrounding watershed were actively monitored. This included six primary sources of AMD. Conductivity measurements > 1,000 microhmos/cm were found at eight sites and pH was consistently below 6.0 at seven. Of six metals analyzed, magnesium was highest in the water column, ranging from 16.5 mg/L to 130 mg/L. Aluminum and iron were both elevated in the sediment with iron concentrations as high as 176,000 mg/kg. An increase in sediment metal concentrations was noted when progressing downstream in the creek. Of nine high wall and spoils areas ...
1996-11-17
Water Quality and 401 Certification | Clean Water Act | US EPA
Clean Water Act You are here: Water Laws & Regulations Policy & Guidance Clean Water Act Water Quality and 401 Certification Water Quality and 401 Certification Water Quality...
2011-08-28
Energy Technology Data Exchange (ETDEWEB)
Previous studies have found that classrooms are often inadequately ventilated, with the resultant increased risk of negative impacts on the pupils. This paper describes a series of field measurements that investigated the indoor air quality, thermal comfort and acoustic performance of nine recently built secondary schools in England. The most significant conclusion is that the complex interaction between ventilation, thermal comfort and acoustics presents considerable challenges for designers. The study showed that while the acoustic standards are demanding it was possible to achieve natural ventilation designs that met the criteria for indoor ambient noise levels when external noise levels were not excessive. Most classrooms in the sample met the requirement of limiting the daily average CO{sub 2} concentration to below 1500 ppm but just a few met the need to readily provide 8 l/s per person of fresh air under the easy control of the ...
2009-07-15
Should high-level nuclear waste be disposed of at geographically dispersed sites?
Energy Technology Data Exchange (ETDEWEB)
Consideration of the technical feasibility of Yucca Mountain in Nevada as the site for a high-level nuclear waste repository has led to an intense debate regarding the economic, social, and political impacts of the repository. Impediments to the siting process mean that the nuclear waste problem is being resolved by adhering to the status quo, in which nuclear waste is stored at scattered sites near major population centers. To assess the merits of alternative siting strategies--including both the permanent repository and the status quo- we consider the variables that would be included in a model designed to select (1) the optimal number of disposal facilities, (2) the types of facilities (e.g., permanent repository or monitored retrievable facility), and (3) the geographic location of storage sites. The objective function in the model is an all-inclusive measure of social cost. The intent of the exercise is not to demonstrate the superiority ...
1992-07-01
Risk perception on management of nuclear high-level and transuranic waste storage
Energy Technology Data Exchange (ETDEWEB)
The Department of Energy`s program for disposing of nuclear High-Level Waste (HLW) and transuranic (TRU) waste has been impeded by overwhelming political opposition fueled by public perceptions of actual risk. Analysis of these perceptions shows them to be deeply rooted in images of fear and dread that have been present since the discovery of radioactivity. The development and use of nuclear weapons linked these images to reality and the mishandling of radioactive waste from the nations military weapons facilities has contributed toward creating a state of distrust that cannot be erased quickly or easily. In addition, the analysis indicates that even the highly educated technical community is not well informed on the latest technology involved with nuclear HLW and TRU waste disposal. It is not surprising then, that the general public feels uncomfortable with DOE`s management plans for with nuclear HLW and TRU waste disposal. Postponing the permanent geologic ...
1994-08-15
Rehabilitation of a gassy low pressure liquid filled 115 kV cable
Energy Technology Data Exchange (ETDEWEB)
The recent attempt to degassify a self contained liquid filled (SCLF) cable in Ontario Hydro is described. In September 1989, there was a high pressure alarm on one phase of a SCLF 115 kV cable circuit. The direct buried cable circuit is about 1,890 m long with two joints and was installed in 1968. Oil samples from the cable had 10 to 12% gas content with high levels of hydrogen, methane, and ethane, and very low levels of carbon monoxide, carbon dioxide, and acetylene. From these results it was concluded that the gas was generated by low energy electrical discharges and the paper insulation was not degraded. Various utilities and cable manufacturers were contacted to find if they had experienced similar problems. The cable duct oil was flushed and gasified and the successive oil samples were analyzed in order to locate the gassing site. The joints were examined and oil samples were taken through holes drilled in the cable sheath. From the test ...
1994-12-31
Radon concentration measurements in mofettes from Harghita and Covasna Counties, Romania
Energy Technology Data Exchange (ETDEWEB)
In the Harghita volcanic range (Romania) there are many occurrences of dry CO{sub 2} emanations, called mofettes. The emanating gas with high carbon dioxide content has a proved curative effect. The gas also contains important quantities of radon. Since the mofettes are used in curative purposes in several illnesses, in most of the cases without medical supervising, has been proposed to determine the radon activity concentration in some of the most frequented mofettes from Romania. The seasonal variations have also been monitored and were calculated the effective doses received by the patients during a cure. The radon activity concentrations' levels above the mofettes indoor air range between 548 and 10 717 Bq/m{sup 3} while within the gas pools' values between 3210 and 32 781 Bq/m{sup 3} have been measured. The effective dose received by the patients during a cure is between 0.0086 and 0.16 mSv. No major seasonal variations ...
2008-12-15
Radon concentration measurements in mofettes from Harghita and Covasna Counties, Romania
International Nuclear Information System (INIS)
In the Harghita volcanic range (Romania) there are many occurrences of dry CO2 emanations, called mofettes. The emanating gas with high carbon dioxide content has a proved curative effect. The gas also contains important quantities of radon. Since the mofettes are used in curative purposes in several illnesses, in most of the cases without medical supervising, has been proposed to determine the radon activity concentration in some of the most frequented mofettes from Romania. The seasonal variations have also been monitored and were calculated the effective doses received by the patients during a cure. The radon activity concentrations' levels above the mofettes indoor air range between 548 and 10 717 Bq/m3 while within the gas pools' values between 3210 and 32 781 Bq/m3 have been measured. The effective dose received by the patients during a cure is between 0.0086 and 0.16 mSv. No major seasonal variations of the radon activity concentrations ...
2008-12-01
Liquid waste evaporator operating experience
Energy Technology Data Exchange (ETDEWEB)
Atomic Energy of Canada Limited (AECL) operates the Waste Treatment Centre (WTC) to treat and immobilize some of the low- level radioactive waste (LLRW) streams at the Chalk River Laboratories (CRL). The WTC at treats low- level radioactive liquid waste by removing the contaminants from the wastewater, concentrating them, and immobilizing them. The fundamental design concept for the WTC is to process the waste streams using forced circulation type liquid waste evaporation (LWE), to solidify the concentrates using thin film evaporator and to discharge the purified effluent into the Ottawa River following verification monitoring. The solidified product drums are stored in existing storage facilities in the CRL. The LWE was installed in the WTC to treat the LLRW. After about four (4) years of design, construction and cold commissioning, the active commissioning of the evaporator process using radioactive waste streams ...
2006-07-01
Liquid waste evaporator operating experience
International Nuclear Information System (INIS)
Atomic Energy of Canada Limited (AECL) operates the Waste Treatment Centre (WTC) to treat and immobilize some of the low- level radioactive waste (LLRW) streams at the Chalk River Laboratories (CRL). The WTC at treats low- level radioactive liquid waste by removing the contaminants from the wastewater, concentrating them, and immobilizing them. The fundamental design concept for the WTC is to process the waste streams using forced circulation type liquid waste evaporation (LWE), to solidify the concentrates using thin film evaporator and to discharge the purified effluent into the Ottawa River following verification monitoring. The solidified product drums are stored in existing storage facilities in the CRL. The LWE was installed in the WTC to treat the LLRW. After about four (4) years of design, construction and cold commissioning, the active commissioning of the evaporator process using radioactive waste streams ...
2005-05-08
Free release waste characterisation during the decommissioning of windscale Pile 2 Chimney
International Nuclear Information System (INIS)
The decommissioning of windscale Pile 2 Chimney resulted in the removal of one of most historically significant and prominent features of the Sellafield site. The project was the first large scale concrete ''free release'' operation to be undertaken on the Sellafield nuclear site, producing 4500 tons of concrete of which 3000 tons was demonstrated to be ''free release''. The paper describes the radiometric techniques employed in the characterisation and segregation of the concrete into low level waste (LLW), very low level waste (VLLW) and free release categories. It examines the robust solutions that were developed to meet the technical and regulatory challenges of the project, which included the definition of free release, the selection of averaging volumes, the testing and validation of the monitoring systems employed for ton quantities of concrete and the identification and removal of small numbers of fuel particles ...
2002-09-22
Connecting section and associated systems concept for the spray calciner/in-can melter process
Energy Technology Data Exchange (ETDEWEB)
For a number of years, researchers at the Pacific Northwest Laboratory have been developing processes and equipment for converting high-level liquid wastes to solid forms. One of these processes is the Spray Calciner/In-Can Melter system. To immobilize high-level liquid wastes, this system must be operated remotely, and the calcine must be reliably conveyed from the calciner to the melting furnace. A concept for such a remote conveyance system was developed at the Pacific Northwest Laboratory, and equipment was tested under full-scale, nonradioactive conditions. This concept and the design of demonstration equipment are described, and the results of equipment operation during experimental runs of 7 d are presented. The design includes a connecting section and its associated systems - a canister sypport and alignment concept and a weight-monitoring system for the melting furnace. Overall, the runs demonstrated that the ...
1981-06-01
International Nuclear Information System (INIS)
Sources of radon and pathways in which radon can reach dwelling-rooms are shortly discussed. In continuation of the previous measurements of radon in Swiss dwellings with track detectors and working level monitors, a complementary passive method for radon concentration measurements indoors and radon exhalation rate measurements from walls and soil surfaces is introduced. Radon decay products concentrations, air temperature gradients and wind velocities were measured continuously in four Swiss dwellings during several weeks in autumn and winter of 1985/86. The Rn-222 concentrations indoors ranged from about 10 Bq/m"3 in two houses in the Eastern Jura up to more than 23,000 Bq/m"3 in two houses situated in the Central Alps. Indoor equilibrium factors between 0.1 up to 0.5 with distinct dependences on floor-levels have been found. The influence of the temperature gradient between the oudoor and indoor air on the indoor radon ...
Air pollutants emissions from waste treatment and disposal facilities.
This study examined the atmospheric pollution created by some waste treatment and disposal facilities in the State of Kuwait. Air monitoring was conducted in a municipal wastewater treatment plant, an industrial wastewater treatment plant established in a petroleum refinery, and at a landfill site used for disposal of solid wastes. Such plants were selected as models for waste treatment and disposal facilities in the Arabian Gulf region and elsewhere. Air measurements were made over a period of 6 months and included levels of gaseous emissions as well as concentrations of volatile organic compounds (VOCs). Samples of gas and bioaerosols were collected from ambient air surrounding the treatment facilities. The results obtained from this study have indicated the presence of VOCs and other gaseous pollutants such as methane, ammonia, and hydrogen sulphide in air surrounding the waste treatment and disposal facilities. In some cases the ...
2006-01-01
International Nuclear Information System (INIS)
Active oxygens produced by low-dose irradiation can induce the synthesis of proteins involved in the active oxygen reduction path and can activate the chemical self-defense mechanisms in vivo, which can alleviate the injuries caused by active oxygens themselves. The following findings suggests that it is not only by low-dose irradiation that can induce the responses described above but also by any physical and/or chemical stresses which can produce small amount of active oxygens in vivo. 1. X-irradiation with 0.5 Gy and/or water immersion and restraint induced heat shock protein (HSP)70 in rat stomach cells. HSP70 was also induced in adrenal cells by paraquat administration. 2. The SOD activity in pancreas of rat significantly increased by #gamma#-irradiation with 0.5 Gy. 0.5 Gy irradiation preceeding the alloxan administration significantly suppressed the increase in pancreatic lipid peroxides and in blood glucose levels, degranulation in ...
Selective emitter using porous silicon for crystalline silicon solar cells
Energy Technology Data Exchange (ETDEWEB)
This study is devoted to the formation of high-low-level-doped selective emitter for crystalline silicon solar cells for photovoltaic application. We report here the formation of porous silicon under chemical reaction condition. The chemical mixture containing hydrofluoric and nitric acid, with de-ionized water, was used to make porous on the half of the silicon surface of size 125 x 125 cm. Porous and non-porous areas each share half of the whole silicon surface. H{sub 3}PO{sub 4}:methanol gives the best deposited layer with acceptable adherence and uniformity on the non-porous and porous areas of the silicon surface to get high- and low-level-doped regions. The volume concentration of H{sub 3}PO{sub 4} does not exceed 10% of the total volume emulsion. Phosphoric acid was used as an n-type doping source to make emitter for silicon solar cells. The measured emitter sheet resistances at the high- and ...
2009-06-15
Hyperspectral and Multispectral Remote Sensing at Uranium Processing Facilities
Energy Technology Data Exchange (ETDEWEB)
Many mines and processing facilities are in remote, difficult to access areas, or are in areas where access is limited or restricted for national reasons. In a joint project with Canada Centre for Remote Sensing, the Canadian Safeguards Support Program is investigating utility of multi- and hyperspectral remote sensing for remotely inspecting such site. With a view to eventually using the hyperspectral satellite data now coming available, airborne data over uranium and copper mine tailings and uranium processing facilities in northern Canada were acquired. The objective of this work is to demonstrate that multispectral and hyperspectral data can provide complementary and supplementary information to high-resolution panchromatic imagery for the following safeguards applications: Inspection aids (up-to-date maps of remote locations), change detection, evaluation of member state declarations, monitoring of reactor, mining and processing facility operations, and ...
2003-05-01
The Rio Grande alluvial floodplain aquifer between El Paso/Juarez and Fort Quitman, Texas has been intensively tilled and irrigated since 1910. Almost since that time, the Rio Grande and its interconnected alluvial aquifer in this stream reach have been affected by excessive salinity problems. Presently, salinity of surface water and groundwater increases from 800 to 2000 mg/L total dissolved solids (TDS) near El Paso, Texas to 2500 to 5500 mg/L TDS near Fort Quitman, Texas, approximately 115 km downstream. Chloride (Cl) and Chloride/Bromide (Cl/Br) ratios increase downstream, with a marked increase in salinity beginning about 45 km below El Paso. Groundwater sampling in an intensively investigated reach of the floodplain aquifer, extending from 35 to 60 km below El Paso identified two distinct water types. The first water type (17 samples) is a relatively dilute groundwater containing 1000 to 2000 mg/L TDS, 250 to 600 ...
2005-12-01
Urticaria due to Urtica dioica in a neonate
British Library Electronic Table of Contents (United Kingdom)
Urticaria is one of the most common dermatoses during the childhood, but it is very rare in the neonates. A 17-day-old infant with a generalized urticaria was admitted to our pediatric emergency unit. The mother of the infant reported having applied water boiled with stinging nettle (Urtica dioica) onto her nipples twice a day (before and after each breastfeeding) for 2?days in order to heal her nipple cracks. Serum total immunoglobulin E (IgE) and specific IgE levels for stinging nettle were high in the infant and the mother. The rashes began to regress within the first day of the hospitalization and disappeared completely on the second day without treatment. The skin prick test with the water boiled with stinging nettle was positive for the infant with significant induration, but not for...
2011-01-01
Two-phase flow regime characterization in a PWR hot leg with candy cane geometry
International Nuclear Information System (INIS)
This paper describes a series of tests investigating two-phase flow regimes in a transparent model of a PWR hot leg. Test conditions were selected to cover a wide range of gas and liquid superficial velocities (.01 m/s 2 m/s) were also performed for comparison with semi-analytical predictions. Results include average void fractions, flow rates, and visual characterizations of the two-phase flow phenomena. Results show generally good agreement with Taitel and Duckler flow regime map and Zuber-Findlay correlation for average void fraction in vertical pipes. Results also indicate that flow regimes and collapsed liquid level (void fraction) are more strongly dependent on air flow rate (air superficial velocity) than water flow rate (water superficial velocity).
1984-10-01
Combined sewer overflows (CSOs) have been recognised as one of the serious sources of pollution to the water environment during rain events, although field surveys to investigate the effect of their magnitude and duration on receiving waters have been very limited. The fates of enteric viruses (norovirus G1, G2, enteroviruses) and coliforms were determined in the wastewater treatment plant on a fine day and on a rainy day. Not all microorganisms were reduced in the primary treatment, but were reduced in the secondary treatment. Occurrences of enteric viruses and levels of coliforms were surveyed in the receiving coastal area after a CSO event, with the profiles of the enteric viruses in the coastal seawater being almost at the same positive ratio for 4 d after the CSO event. PMID:15318519
2004-01-01
British Library Electronic Table of Contents (United Kingdom)
This study presents monthly estimates of groundwater anomalies in a large river basin dominated by extensive floodplains, the Negro River Basin, based on the synergistic analysis using multisatellite observations and hydrological models. For the period 2003-2004, changes in water stored in the aquifer is isolated from the total water storage measured by GRACE by removing contributions of both the surface reservoir, derived from satellite imagery and radar altimetry, and the root zone reservoir simulated by WGHM and LaD hydrological models. The groundwater anomalies show a realistic spatial pattern compared with the hydrogeological map of the basin, and similar temporal variations to local in situ groundwater observations and altimetry-derived level height measurements. Results highlight th...
2011-01-01
Quantum simulation of molecular interaction and dynamics at surfaces
British Library Electronic Table of Contents (United Kingdom)
The interaction between molecules and solid surfaces plays important roles in various applications, including catalysis, sensors, nanoelectronics, and solar cells. Surprisingly, a full understanding of molecule-surface interaction at the quantum mechanical level has not been achieved even for very simple molecules, such as water. In this mini-review, we report recent progresses and current status of studies on interaction between representative molecules and surfaces. Taking water/metal, DNA bases/carbon nanotube, and organic dye molecule/oxide as examples, we focus on the understanding on the microstructure, electronic property, and electron-ion dynamics involved in these systems obtained from first-principles quantum mechanical calculations. We find that a quantum mechanical description ...
2011-01-01
Method of feeding a coolant into a reactor
International Nuclear Information System (INIS)
Object: To suppress a quantity of impurities in a coolant fed into a reactor vessel. Structure: The concentration of oxygen in a coolant flowing from a condensation desalting instrument into a feed and condensation piping is measured by an oxygen-concentration detector to feed its signal to an adjusting instrument. A degree of opening of an oxygen flow control valve to maintain the concentration of oxygen in the cooling water flowing within the pipe in the range from about 10 to about 200 ppb. Also, the concentration of oxygen in the cooling water fed to the desalting instrument is maintained at a level less than 2 ppb. Thereby, the total amount of iron flown into the vessel can be suppressed to a fine amount such as less than about 1 ppb. (Kawakami, Y.).
Measurement of Lake Roosevelt biota in relation to reservoir operations. Appendices 1991
International Nuclear Information System (INIS)
This report consists of appendices A-F containing the biological data which were collected from Lake Roosevelt, Washington. The data are to be used in the design of a computer model that would predict biological responses of reservoir operations as part of the System Operation Review program. Major components of the model included: Quantification of impacts to phytoplankton, zooplanktons, benthic invertebrates, and fish caused by reservoir drawdowns and low water retention times; quantification of number, distribution, and use of fish food organisms in the reservoir by season; determination of seasonal growth of fish species as related to reservoir operations, prey abundance and utilization; and quantification of entrainment levels of zooplankton and fish as related to reservoir operations and water retention times.
1995-11-05
Gross decontamination experiment report
International Nuclear Information System (INIS)
A Gross Decontamination Experiment was conducted on various levels and surfaces of the TMI - Unit 2 reactor building in March 1982. The polar crane, D-rings, missile shields, refueling canals, refueling bridges, equipment, and elevations 305' and 347'-6'' were flushed with low pressure water. Additionally, floor surfaces on elevation 305' and floor surfaces and major pieces of equipment on elevation 347'-6'' were sprayed with high pressure water. Selective surfaces were decontaminated with a mechanical scrubber and chemicals. Strippable coating was tested and evaluated on equipment and floor surfaces. The effectiveness, efficiency, and safety of several decontamination techniques were established for the large, complex decontamination effort. Various decontamination equipment was evaluated and its effectiveness was documented. Decontamination training and procedures were documented and evaluated, as were the support system ...
British Library Electronic Table of Contents (United Kingdom)
Shallow-water zooplanktivorous fish rely on their vision for foraging. In shallow water, feeding efficiency decreases in dim light and thus the fish cease foraging at crepuscular hours. Creatures living in the lower parts of their depth ranges are expected to be exposed to limited light levels for longer hours. However, observations of the zooplanktivore Dascyllus marginatus showed little change in foraging duration down to 40m deep. We asked whether the visual system's functionality changes with depth along the depth range of this damselfish; we examined eye and retina anatomy for changes in visual acuity and light sensitivity and used the optomotor response to test for spatial and temporal light summation. We found only minor changes in the anatomy of the eye that are not expected to aff...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
Validity of fern spore germination bioassays for the effects of environmental pollution was established by many researchers. Some workers studied the phytotoxicity of linear alkyl benzene sulfonate (LAS) on the spores of Diplazium esculentum and observed that LAS levels above 0.001% are toxic to fern spores. Water pollution due to synthetic detergents has been increasing continuously during the last few years due to their extensive use in domestic life, agriculture and industry. These detergents are among the most common pollutants responsible for water pollution. In view of this fact, the phytotoxicity of LAS on germination of an aquatic fern Ceratopteris thalictroides spores was studied. However, in these studies, only germination pattern was taken as index and no observations were made on the developmental stages.
1989-07-01
Development of ultrafiltration and adsorbents: October 1979-March 1980
Energy Technology Data Exchange (ETDEWEB)
Tests on a sample of trench water from the Maxey Flats burial ground effectively demonstrated the new Reverse Osmosis Pilot Plant. The effluent from the 50% salt-rejection membrane was decontaminated well enough with the exception of tritium to be discharged to the environment. The performance of the 97% salt-rejection membrane was superior to that of the 50% membrane. A breakthrough and capacity experiment was conducted with Durasil 10 on a simulated Three Mile Island solution. The maximum decontamination factor was extrapolated to be 10/sup 6/, which would reduce the cesium level of TMI water to below the discard limit. Capacity (1/DF = 0.5) was reached at 1260 column volumes. Several adsorbents were tested in the engineering columns for decontamination of cesium-bearing solutions. Under the conditions of the experiment, these adsorbents were ineffective in removing cesium from the solution.
1980-07-02
Contamination of sites formerly occupied by Russian troops in Poland
Energy Technology Data Exchange (ETDEWEB)
This paper summarizes an investigation carried out on Polish terrain occupied by Russian Federation military troops. The investigation identified natural environmental devastation, pollution, and contamination. Quantitative estimation of the devastation and its economic evaluation are provided. The results of the investigation are as follows: 406 ha have been contaminated by petrochemical products; 22.7 ha are chemically polluted; and 6,500 ha of underground water, as well as 17.5 ha of surface water, cannot be classified. On 15,300 ha the soil has been degraded, of which landfills comprise an area of 98 ha. No toxic warfare agents have been detected, nor any radioactivity levels exceeding those characteristic of the given region.
1995-12-31
Advanced Neutron Source: Plant Design Requirements
Energy Technology Data Exchange (ETDEWEB)
The Advanced Neutron Source will be a new world-class facility for research using hot, thermal, cold, and ultra-cold neutrons. The heart of the facility will be a 330-MW (fission), heavy-water cooled and heavy-water moderated reactor. The reactor will be housed in a central reactor building, with supporting equipment located in an adjoining reactor support building. An array of cold neutron guides will fan out into a large guide hall, housing about 30 neutron research stations. Appropriate office, laboratory, and shop facilities will be included to provide a complete facility for users. The ANS is scheduled to begin operation at the Oak Ridge National Laboratory early in the next decade. This PDR document defines the plant-level requirements for the design, construction, and operation of ANS. It also defines and provides input to the individual System Design Description (SDD) documents. Together, this PDR document and the ...
1990-07-01
International Nuclear Information System (INIS)
A study on the distribution of "1"3"7Cs in coastal waters up to a distance of 15 km was undertaken for a decade (1995-2004) and observed that the activity has reduced by 15-20 fold. Statistical and trend analysis was carried out to resolve the contribution of different facilities at a distance of 5 km (north and south) from the discharge point by log normal probability analysis and found that at 5 km south, the median value of "1"3"7Cs due to TAPS and FRP discharges were 3.7 mBq/l and 1.50 mBq/l respectively. The observed levels of "1"3"7Cs are of no consequences from the point of view of dose to members of the public. (author)
2005-11-23
Implementation of an inclusive radiation monitoring system in the Bragin district in Belarus
Energy Technology Data Exchange (ETDEWEB)
This paper presents results from one of the projects developed within the general framework of the international Programme 'CORE' (Cooperation for Rehabilitation in Belarus). The overall objective of the programme is to make sustainable improvements to the living conditions of the inhabitants of the territories affected by the Chernobyl disaster. The CORE Programme is currently developed in four contaminated districts of Belarus (Bragin, Cherchersk, Slavgorod and Stolyn) in the following four areas: economic and social development; health care and surveillance; education and culture; and radiological quality. The project that is presented here refers specifically to the field of 'radiological quality' and will last until the end of 2008. The project named 'implementation of an inclusive radiation monitoring system' was launched in April 2004 in the Bragin district, which is one of the most contaminated areas in ...
2006-07-01
Weakly penetrating radiation monitoring and assessment at Daya Bay Nuclear Power Plant
International Nuclear Information System (INIS)
Weakly penetrating radiation monitoring and investigating with area monitors and individual dosimeters were carried out at Daya Bay nuclear power plant during its refueling outages. This paper introduces monitoring methods, measuring results, data analysis and assessment, presents some suggestions for monitoring plan and protection measures in the future as well. (authors)
2006-05-01
POP bioaccumulation in macroinvertebrates of alpine freshwater systems
International Nuclear Information System (INIS)
This study serves to investigate the uptake of POPs in the different trophic levels (scrapers, collectors, predators, shredders) of macroinvertebrate communities sampled from a glacial and a non-glacial stream in the Italian Alps. The presented results show that the contaminant concentrations in glacial communities are generally higher compared to those from non-glacial catchments, highlighting the importance of glaciers as temporary sinks of atmospherically transported pollutants. Moreover, the data also suggests that in mountain systems snow plays an important role in influencing macroinvertebrate contamination. The main chemical uptake process to the macroinvertebrates is considered to be bioconcentration from water, as similar contaminant profiles were observed between the different trophic levels. The role of biomagnification/bioaccumulation is thought to be absent or negligible. The enrichment of chemicals observed in ...
2009-12-01
Low-level radioactive waste disposal in the oceans
Energy Technology Data Exchange (ETDEWEB)
A strategy for the management of the disposal of low-level radioactive wastes into coastal zones and ocean waters has developed over the past three decades. While there has been a substantial increase in the number of international and required agreements there has also been a concomitant improvement in our understanding of the ocean and the processes at work within it. This has allowed more rigorous and reliable assessments to be made of the radiological consequences. With the continued development of basic guidelines of radiological protection by the International Commission on Radiological Protection (ICRP) methodologies have been formulated to derive the fundamental scientific requirement - the relationship between disposal or release rate to the ocean and the resultant radiation dose to exposed human populations.
1983-04-01
Development of a pelleted waste form for high-level alumina wastes
Energy Technology Data Exchange (ETDEWEB)
A formulation to pelletize simulated high-level ICPP alumina waste calcine was developed. The pellets are formed on a 41-cm-diameter disc pelletizer using 5% bentonite, 2% metakaolin, and 5 wt % calcium hydroxide as a solid binder and a solution of 7M phosphoric acid and 4M nitric acid as a liquid binder. After drying and heat treatment at 800/sup 0/C for 2 hours, the average crush strength of the pellets is 3.9 MPa and the pellets have a leach resistance of 10/sup -3/ g/cm/sup 2//day, based on Soxhlet leaching for 48 h at 95/sup 0/C with distilled water.
1980-09-01
British Library Electronic Table of Contents (United Kingdom)
The heating of water layer using microwave oven with a rectangular waveguide has been studied both numerically and experimentally. The mathematical model is validated with the experimental data. The transient Maxwell's equations are solved by using the Finite Difference Time Domain (FDTD) method to describe the electromagnetic field inside the waveguide and sample. The temperature profile and velocity field within sample are determined by the solutions of the momentum, energy and Maxwell's equations. In this study, the effects of physical parameters, e.g. microwave power level, placement of sample inside the waveguide, volume of sample, are studied. The distribution of electric field, temperature profile and velocity field are presented in details. The results show good agreement between s...
2012-01-01
Variable-speed generation enhances hydro operation
Energy Technology Data Exchange (ETDEWEB)
Two major developments have given impetus to wider adoption of variable-speed turbine/generators in hydroelectric plants, both essentially environmental: (1) the need for stream-bed stability below river dams, and (2) the need to minimize fish damage. Also, the need to stabilize pumped-storage and generating efficiencies to match extreme changes in head levels has been a driving force. Variable-speed operation in hydro applications is relatively new to North America. In other parts of the world, it has been used in pumped-storage plants since 1971. In the US, and increasing potential exists for variable-speed hydro, considering the 30 pumped-storage plants already in operation and several river plants struggling with high head fluctuations--including four at stations operated by the Bonneville Power Administration. Several modifications to hydro-plant hardware and operating procedures are actively being considered at Bonneville--all of them practical but costly. ...
1993-07-01
Populations of a common forage fish, red shiner Notropis lutrensis, were sampled from four localities on the Brazos River, Texas, affected by cold-water discharge from a hydroelectric dam and from unaltered sites in the same region. Polymorphism at the Mdh-B locus, encoding supernatant malate dehydrogenase, indicates that populations within 57 km of the dam are distinctive from other regional populations and possess a unique Mdh-B allele, have significantly higher levels of heterozygosity at the Mdh-B locus, represent a homogeneous set that have significantly different Mdh-B zygotic frequencies from other regional populations, and have significantly different Mdh-B zygotic proportions than would be expected under a Hardy-Weinberg equilibrium. Increased levels of heterozygosity in fish within 57 km of the dam were correlated with discharge-associated fluctuations in water temperature at sampling ...
1981-05-01
Energy Technology Data Exchange (ETDEWEB)
A cost study is described which compared the economics of four dry/wet cooling systems to use at the existing Raft River Geothermal Plant. The results apply only at this site and should not be generalized without due consideration of the complete geothermal cycle. These systems are: the Binary Cooling Tower, evaporative condenser, Combin-aire, and a metal fin-tube dry cooling tower with deluge augmentation. The systems were evaluated using cooled, treated geothermal fluid instead of ground or surface water in the cooling loops. All comparisons were performed on the basis of a common plant site - the Raft River 5 MWe geothermal plant in Idaho. The Binary Cooling Tower and the Combin-aire cooling system were designed assuming the use of the isobutane/water surface condenser currently installed at the Raft River Plant. The other two systems had the isobutane ducted to the evaporative condensers. Capital credit was not given to the system employing ...
1982-07-01
International Nuclear Information System (INIS)
A detailed outline of the application of the MELCOR and RELAP5/MOD3.1 codes to the analysis of the thermohydraulic response and determination of other parameters of the medium on the floor is given for several classes of secondary coolant circuit accidents along with the description of the related facilities. An overview is presented of the maximum values and time behavior of the thermohydraulic parameters, pressure, temperature, relative humidity, and water level on the floor. Transverse rupture of the steam generator, main steam header, or main feedwater header piping during normal operation is considered as the initiating event. Pressure is only 10% higher than the atmospheric pressure. Air temperature attains a value as high as 100 degC. Relative humidity is 100%, persisting as long as the steam source is available. The water level is typically about 8 cm and never exceeds 15 cm. (M.D.). 16 tabs., ...
Climate - air traffic emissions
Energy Technology Data Exchange (ETDEWEB)
In 1990, 176 million tonnes (mt) of air-traffic fuel was burned, which produced about 550 mt CO{sub 2}, 220 mt water, 3.5 mt NO{sub x} amd 0.18 mt SO{sub 2}. NO{sub x} emissions from air traffic may, by increasing ozone concentrations, be responsible for about 8% of global greenhouse warming. In the stratosphere NO{sub x} from aircraft is partly responsible for ozone depletion. With present technology 500 aircraft in the stratosphere would cause global ozone losses of 20%. Water vapour added by aircraft also contributes to global warming. In the form of ice crystals between 8 to 13 km above sea level, it acts as cirrus clouds. Probably the least damaging cruising altitude for aircraft is 9 km above sea level. Fuel consumption by aircraft is increasing. Air pollution abatement measures include substituting hydrogen fuel for kerosene, developing engines that emit less NO{sub x} and the introduction of ...
1991-11-01
An analysis of PZR and related system design features for KNGR
Energy Technology Data Exchange (ETDEWEB)
The development of KNGR (Korean Next Generation Reactor) is now in progress. KAERI is developing KNGR which is a advanced active PWR (pressurized water reactor) and 1350 MW electric capacities and is by based on UCN(Ulchin) 3 and 4 nuclear power plant which is a Korean standard PWR. In this report, the PZR (pressurizer) and Related System Design Features for KNGR which include PZR volume, PPCS (pressurizer safety valve)were analyzed. First, the Design Parameters between KNGR compared to UCH 3 and 4 were compared, and second, advanced design features of KNGR compared to UCN 3 and 4 were analyzed. After the present analysis, it has been concluded that the safety margins for the PZR level and pressure of KNGR were more increased by the larger PZR volume than those of UCN 3 and 4, for PZR minimum water level at reactor/turbine trip and PZR maximum pressure at LOCV(loss of condenser vacuum) of KNGR were ...
1995-12-01
British Library Electronic Table of Contents (United Kingdom)
Abstract BACKGROUND: Nitrate leaching and the resulting groundwater contamination from intensive cereal production has become a major concern for long-term farmland efficiency and environmental sustainability in northern China. The aim of this study was to evaluate a water-saving super-absorbent polymer (SAP) for minimising NO3- leaching from soil and optimising corn growth and yield. Thirty-six undisturbed soil lysimeters were installed in a field lysimeter facility in drought-affected northern China to study the growth and yield characteristics of summer corn (Zea mays L.) as well as the amount of NO3-leaching losses under different fertiliser (standard, medium or 75% and low, or 50% of conventional fertilisation rate) and SAP (control, 0; level-1, 15 kg ha-1 and level-2, 30 kg ha-1) tre...
2011-01-01
International Nuclear Information System (INIS)
The role of macroinvertebrates and diatoms as indicator for metal pollution was investigated by assessing both biota along a metal gradient in the Belgian river the Dommel. Macroinvertebrates and diatoms were sampled in summer and winter and physical-chemical characteristics of the water were measured at four different sample periods and related to sediment characteristics. Although metal concentrations, except cadmium, in the water nowhere exceeded water quality standards, high metal concentrations were measured in the sediment, indicating historical contamination of the Dommel. At the sites that were situated downstream of the pollution source, high levels of conductivity and chloride were measured in the water. Redundancy Analysis (RDA) indicated pH, phosphate and zinc as the significant environmental variables explaining each respectively 7.7%, 11.6% and 22.6% of the ...
2008-12-15
International Nuclear Information System (INIS)
A typical form of change in runoff characteristics caused by the widespread use of hydroelectric power in Switzerland is the intermittent draining (torrent operation). It is the aim of the present work to help elucidate possible consequences of these changes in drain onto the benthobiocoenosis. The study was carried through on the Secklisbach at Oberrickenbach (in the semicanton of Nidwalden) and one of its side streamlets (800m above sea level). The macroinvertebrate coenosis was studied at four locations with similar conditions of drainage basin, population density and topography but varying in the degree of impairment to the draining. There were monthly benthos samples taken using a Surber sampling-device. Results show that the locations not only varied in drain, but also in temperature, this being a consequence of water storage by the power plant. The readings pointed out different values for the locations in daily average temperature, day ...
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
