WorldWideScience
1

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 3, Water heaters, pool heaters, direct heating equipment, and mobile home furnaces  

Energy Technology Data Exchange (ETDEWEB)

This is Volume 3 in a series of documents on energy efficiency of consumer products. This volume discusses energy efficiency of water heaters. Water heaters are defined by NAECA as products that utilize oil, gas, or electricity to heat potable water for use outside the heater upon demand. These are major appliances, which use a large portion (18% on average) of total energy consumed per household (1). They differ from most other appliances in that they are usually installed in obscure locations as part of the plumbing and are ignored until they fail. Residential water heaters are capable of heating water up to 180{degrees}F, although the setpoints are usually set lower.

1993-11-01

2

A novel domestic electric water heater model for a multi-objective demand side management program  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a novel domestic hot water heater model to be used in a multi-objective demand side management program. The model incorporates both the thermal losses and the water usage to determine the temperature of the water in the tank. Water heater loads are extracted from household load data and then used to determine the household water usage patterns. The benefits of the model are: (1) the on/off state of the water heater and temperature of the water in the tank can be accurately predicted, and (2) it enables the development of water usage profiles so that users can be classified based on usage behaviour. As a result, the amount of ancillary services and peak shaving that can be achieved are accurately predictable and can be maximized without ...

2010-12-15

3

Pipe Freeze Prevention for Passive Solar Water Heaters Using a Room-Air Natural Convection Loop: Preprint  

Energy Technology Data Exchange (ETDEWEB)

Conference paper regarding research in the use of freeze prevention for passive solar domestic water heating systems.

2006-05-01

4

Campylomormyrus christyi  

Science.gov (United States)

... is known from the Lower Congo River basin (Matadi), from Pool Malebo (Stanley Pool) and from the ... Marine transport and oil disposal by boats and Matadi pose threats in the region. When the water ... ...

5

Application of the porous media model for the LWR process components  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: A porous media solution PORFLO has been developed for the 3-dimensional two-phase flow by describing the process facility in Cartesian or cylindrical coordinates. The local porosity fraction is applied for distinguishing the fluid filled volumes from the solid structures. The solid structure contribute the two-phase flow through the wall friction, flow area and heat transfer. Optionally the solid structure may contain primary liquid of steam generators, steam in the higher temperature and pressure to be condensed or electrical heating power. By using these optional boundary conditions three different process facilities have been analysed. The thermohydraulic solution based on 5-equation approach, where the conservation equations are solved for the liquid and gas (vapour) mass, mixture momentum (giving the velocity only for the mixture), liquid and gas energy, is described shortly. In addition to that the principles modelling optional boundary ...

2005-07-01

6

The solar energy in Lebanon: an inexhaustible and economical energy  

International Nuclear Information System (INIS)

The article describes the energy in Lebanon. In 1995, 97% of the imported energy was based on hydrocarbons. Fuel and gas oil present 66% of the final energy. Air pollution is mainly caused by the transportation sector (vehicles and buses...) which presents 70% of the global atmospheric pollution. Renewable energy such as biomass, fossil energy, hydro-energy, solar energy... are also described. The solar energy was defined as a best solution that preserve health in Lebanon. The different applications of the solar for energy production is discussed: photovoltaic , thermal heating, sanitary hot water, electrical heaters, solar water heaters...In conclusion, solar heaters economize 80% of the annual energy expenses

1997-06-01

7

Three Dimensional Visualization for the Steam Injection into Water Pool using Electrical Resistance Tomography  

International Nuclear Information System (INIS)

The direct injection of steam into a water pool is a method of heat transfer used in many process industries. The amount of research in this area however is limited to the nuclear industry, with applications relating to reactor cooling systems. Electrical resistance tomography (ERT), a low cost, non-invasive and which has high temporal resolution characteristics, can be used as a visualization tool for the resistivity distribution for the steam injection into water pool such as IRWST. In this paper, three dimensional resistivity distribution of the process is obtained through ERT using iterative Gauss-Newton method. Numerical experiments are performed by assuming different resistive objects in the water pool. Numerical results show that ERT is successful in estimating the resistivity distribution for the injection of steam in the water ...

2010-10-01

8

Northward Market Extension for Passive Solar Water Heaters by Using Pipe Freeze Protection with Freeze-Tolerant Piping: Preprint  

Energy Technology Data Exchange (ETDEWEB)

Conference paper regarding research in freeze-protection methods that could extend market acceptance for passive solar domestic water heating systems in more northern climates if the U.S.

2006-05-01

9

Dynamic load in suppression pool during BWR main steam safety relief valve actuation  

International Nuclear Information System (INIS)

BWRs are so designed that the exhaust steam from main steam safety relief valves is led to pressure suppression pools, and the steam is condensed in pool water, but at this time, dynamic load seems to arise in the pool water. In Tokai No. 2 Power Station, a Mark-2 containment vessel was adopted to improve the reliability as much as possible and to obtain the design with margin. In this report, the result of actual machine test in Tokai No. 2 Power Station and the method of reducing the load are described. When a relief valve works, the discharge of water in exhaust pipes into a suppression pool, the exhaust of air in exhaust pipes and repeated expansion and contraction of bubbles in pool water, and the exhaust of steam and condensation occur. As for the construction of the suppression ...

1979-01-01

10

Radiological characterization of the GRR-1 pool  

International Nuclear Information System (INIS)

GRR-1 is a 5MW open pool type research reactor with MTR-type fuel elements cooled and moderated by light water with beryllium reflectors at the two opposing sides of the core. A graphite thermal neutron column is adjusted to one side of the core. Six radial horizontal beam tubes are available, of which three contain in-pile collimators for neutron scattering instruments. The reactor is currently out of operation for inspection and refurbishment purposes. The core has been dismantled and the fuel elements are stored in the used fuel storage tank. The GRR-1 inspection and refurbishment plan involves inspection and eventually replacement of the reactor's primary cooling circuit. The health physics procedures to be implemented during inspection of the main water outlet are divided in three stages: a) pool dose rate survey from pool top, b) pool drainage by ...

2007-11-05

11

Experimental Study of Nucleate Pool Boiling of FC-72 on Smooth Surface under Microgravity  

British Library Electronic Table of Contents (United Kingdom)

Experiments of highly subcooled nucleate pool boiling of FC-72 with dissolved air were studied both in short-term microgravity condition utilizing the drop tower Beijing and in normal gravity conditions. The bubble behavior and heat transfer of air-dissolved FC-72 on a small scale silicon chip (10 ? 10 ? 0.5?mm3) were obtained at the bulk liquid subcooling of 41?K and nominal pressure of 102?kPa. The boiling heat transfer performance in low heat flux region in microgravity is similar to that in normal gravity condition, while vapor bubbles increase in size but little coalescence occurs among bubbles, and then forms a large bubble remains attached to the heater surface during the whole microgravity period. Thermocapillary convection may be an important mechanism of boiling heat transfer in ...

2011-01-01

12

Market assessment for the fan atomized oil burner  

Energy Technology Data Exchange (ETDEWEB)

The market potential for the fan atomized burner (FAB) in water and space heating applications was examined. The major findings of the study are as follows. (1). The FAB`s low-input capability allows development of oil-fired room heaters and wall furnaces, a new market area for oil heat. (2). Among conventional oil-fired products, furnaces will benefit most from the burner`s low input capability due to (1) their quick delivery of heat and (2) their more prevalent use in warmer climates and smaller homes. (3). The greatest potential for increased product sales or oil sales exists in the use of the burner with new products (i.e., room heaters). Sales of boilers and direct-fired water heaters are not likely to increase with the use of the burner. (4). Acceptance of the burner will be dependent on proof of reliability. Proof of better reliability than conventional burners would ...

1996-07-01

13

Houstongets - Johnson Space Center - NASA  

Science.gov (United States)

Oct 23, 1992 ... washer, water heater, cooktop, roof, fence, sunroof, auto, 81K mi, runs ok, $2.5 K OBO. x39282 or 335-0641. Want a lucit carpet protector 54" ...

14

Indirect heating of natural gas using vapor chambers; Aquecimento indireto de gas natural com uso de camaras de vapor  

Energy Technology Data Exchange (ETDEWEB)

Operation safety and reliability are major guidelines in the design of city-gate units. Conventional natural gas heaters operate by a indirect mechanism, where liquid water is used to transfer heat by natural convection between the combustion chamber and the natural gas coil. In this work, the concept of vapor chamber is evaluated as an indirect gas heater. In a vapor chamber, liquid water is in contact with the heat source, and vaporizes. The vapor condenses in contact with the heat sink. A reduced scale model was built and tested in order to compare these two heating concepts where the combustion chamber was replaced by electrical cartridge heaters. This engineering model can operate either as a conventional heater or as a vapor chamber. The comparison between the concepts was done by inducing a controlled power to the cartridges and by measuring the resulting ...

2005-07-01

15

DWPF Melter No.2 Prototype Bus Bar Test Report  

Energy Technology Data Exchange (ETDEWEB)

Characterization and performance testing of a prototype DWPF Melter No.2 Dome Heater Bus Bar are described. The prototype bus bar was designed to address the design features of the existing system which may have contributed to water leaks on Melter No.1. Performance testing of the prototype revealed significant improvement over the existing design in reduction of both bus bar and heater connection maximum temperature, while characterization revealed a few minor design and manufacturing flaws in the bar. The prototype is recommended as an improvement over the existing design. Recommendations are also made in the area of quality control to ensure that critical design requirements are met.

2003-03-26

16

Cooling facility for reactor container  

International Nuclear Information System (INIS)

Cooling water is sprayed on the outer surface of an upper portion of a container, and a pool is formed by the cooling water flowing down while cooling the container. Further, the cooling water stored in the cooling water pool is recycled by a pump for spraying the cooling water on the outer surface of the upper portion of the container. Sufficient amount of cooling water is supplied for spraying the cooling water to the outer surface of the upper portion of the container so that the outer surface of the container is free from drying and a liquid membrane is formed on the entire surface. The amount of the cooling water is made greater than that of the cooling water evaporated when the entire amount of the heat generate in the reactor core of the reactor is ...

1993-05-07

17

Synchronized Observations of Bubble Growth and Microlayer Evaporation in Horizontal Pool Boiling  

International Nuclear Information System (INIS)

The present study is aiming at the visualization of the boiling structures for various pool boiling and flow boiling conditions by applying multiple visualization techniques simultaneously. The bubble growth rate and microlayer behavior were simultaneously visualized for an isolated boiling regime of a water by using a shadow graph and a total reflection technique, respectively

2010-10-01

18

Structural integrity evaluation of FTL in-pool piping  

Energy Technology Data Exchange (ETDEWEB)

HANARO fuel test loop will be equipped in HANARO to obtain the development betterment of advanced fuel and materials through the irradiation test. The object of this study is to evaluate the structural integrity of FTL in-pool piping by investigating a dynamic analysis of the loop containing a postulated rupture section. The method to perform the dynamic analysis and structural integrity evaluation caused by the pipe whip in water environment can be a reference for a similar structural integrity evaluation. (author). 7 refs., 39 tabs., 34 figs.

1998-05-01

19

Policy development for solar water heaters: the case of Lebanon  

International Nuclear Information System (INIS)

Full text.The electric energy demand in Lebanon is estimated to grow at an average of 3-5% per year for the coming 10 years. Such an increase in energy demand is problematic for Lebanon since its economy is almost totally dependent on imported fuel which contributes to 97% of the overall energy requirements. Solar water heaters (SWH) are regarded as the most important element in a long term energy conservation and management strategy for this country, but their promotion is a national issue requiring the participation of many stake holders and decision makers. Additionally, the success of solar energy penetration into the existing energy market is constrained by many factors such as technical and financial limitations, decision criteria and policy instruments. This paper will explore the feasibility of SWH, and will work out, using the Analytic Hierarchy Process technique, a policy to ensure a large scale diffusion of SWH in the energy market

2000-11-23

20

Emergency core cooling device  

International Nuclear Information System (INIS)

In an existent emergency reactor core cooling device, if a ruptures should occure in a pipeline of a gravitational dropping type reactor core cooling system pool (GDCS) due to some or other causes, a portion of GDCS pool water was flown out of the ruptured port and could not be used for reactor core cooling. Then, a difference pressure detector is disposed to a GDCS pipeline at the inlet of a reactor pressure vessel. When it is judged by the detector, that coolants flow to the outside of the injection pipeline, an injection value disposed to the GDCS pipeline is closed by the difference pressure signal. Even if a rupture should occur on the side of the pressure vessel at downstream to the check value of the GDCS pipeline, since backflow is caused at the pressure container inlet of the GDCS pipeline with the rupture port, the rupture is detected by the difference pressure detector to close the injection valve. Therefore, ...

1990-10-29

21

Freeze protection valve for solar heaters  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a solar heater freeze protection valve apparatus comprising in combination: a valve housing; a remote sensor operatively connected to the valve housing from a remote position, the remote sensor including a bulb containing a liquid adapted to compress and expand with the temperature adjacent the bulb; a piston located in the valve body and slidable responsive to expansion and contraction of the liquid in the remote sensor; a first valve element located in the valve housing and attached to the valve piston for movement; a second valve element located in the valve housing and attached to the housing; a first valve seat in the second valve element forming an opening; a second valve seat positioned in a water passageway to allow the flow of fluid when the second valve element is in an open position and to cut off the flow of fluid when the second valve element is in a closed position. Liquid in a solar ...

1987-07-21

22

Solar desalination using humidification-dehumidification processes. Part II. An experimental investigation  

Energy Technology Data Exchange (ETDEWEB)

An experimental investigation of a humidification-dehumidification desalination (HDD) process using solar energy at the weather conditions of Suez City, Egypt, is presented. A test rig is designed and constructed to conduct this investigation under different environmental and operating conditions. The test rig consists of a solar water heater (concentrator solar collector type), solar air heater (flat plate solar collector type), humidifier tower and dehumidifier exchanger. Different variables are examined including the feed water flow rate, the air flow rate, the cooling water flow rate in the dehumidifier and the weather conditions. Comparisons between the experimental results and other published results are presented. It is found that the results of the developed mathematical model by the same authors are in good agreement with the experimental results. The tested results show ...

2004-05-01

23

Solar desalination using humidification-dehumidification processes. Part II. An experimental investigation  

International Nuclear Information System (INIS)

An experimental investigation of a humidification-dehumidification desalination (HDD) process using solar energy at the weather conditions of Suez City, Egypt, is presented. A test rig is designed and constructed to conduct this investigation under different environmental and operating conditions. The test rig consists of a solar water heater (concentrator solar collector type), solar air heater (flat plate solar collector type), humidifier tower and dehumidifier exchanger. Different variables are examined including the feed water flow rate, the air flow rate, the cooling water flow rate in the dehumidifier and the weather conditions. Comparisons between the experimental results and other published results are presented. It is found that the results of the developed mathematical model by the same authors are in good agreement with the experimental results. The tested results show ...

2004-05-01

24

Solar desalination using humidification dehumidification processes. Pt. 2. An experimental investigation  

Energy Technology Data Exchange (ETDEWEB)

An experimental investigation of a humidification-dehumidification desalination (HDD) process using solar energy at the weather conditions of Suez City, Egypt, is presented. A test rig is designed and constructed to conduct this investigation under different environmental and operating conditions. The test rig consists of a solar water heater (concentrator solar collector type), solar air heater (flat plate solar collector type), humidifier tower and dehumidifier exchanger. Different variables are examined including the feed water flow rate, the air flow rate, the cooling water flow rate in the dehumidifier and the weather conditions. Comparisons between the experimental results and other published results are presented. It is found that the results of the developed mathematical model by the same authors are in good agreement with the experimental results. The tested results show ...

2004-05-01

25

The potential of solar-driven humidification-dehumidification desalination for small-scale decentralized water production  

Energy Technology Data Exchange (ETDEWEB)

World-wide water scarcity, especially in the developing world, indicates a pressing need to develop inexpensive, decentralized small-scale desalination technologies which use renewable resources of energy. This paper provides a comprehensive review of the state-of-the-art in one of the most promising of these technologies, solar-driven humidification-dehumidification (HDH) desalination. Previous studies have investigated many different variations on the HDH cycle. In this paper, performance parameters which enable comparison of the various versions of the HDH cycle have been defined and evaluated. To better compare these cycles, each has been represented in psychometric coordinates. The principal components of the HDH system are also reviewed and compared, including the humidifier, solar heaters, and dehumidifiers. Particular attention is given to solar air heaters, for which design data is limited; and direct air heating ...

2010-05-15

26

Source term attenuation by water in the Mark I boiling water reactor drywell  

Energy Technology Data Exchange (ETDEWEB)

Mechanistic models of aerosol decontamination by an overlying water pool during core debris/concrete interactions and spray removal of aerosols from a Mark I drywell atmosphere are developed. Eighteen uncertain features of the pool decontamination model and 19 uncertain features of the model for the rate coefficient of spray removal of aerosols are identified. Ranges for values of parameters that characterize these uncertain features of the models are established. Probability density functions for values within these ranges are assigned according to a set of rules. A Monte Carlo uncertainty analysis of the decontamination factor produced by water pools 30 and 50 cm deep and subcooled 0--70 K is performed. An uncertainty analysis for the rate constant of spray removal of aerosols is done for water fluxes of 0.25, 0.01, and 0.001 cm{sup 3} H{sub 2}O/cm{sup 2}-s ...

1993-09-01

27

Numerical investigation of boiling regime transition mechanism by a Lattice-Boltzmann model  

Energy Technology Data Exchange (ETDEWEB)

A numerical study has been performed to investigate the hydrodynamic aspects of the pool boiling on horizontal-, vertical- and downward-facing surfaces. The FlowLab code, which is based on a Lattice-Boltzmann (LB) model of two-phase flows, is employed. Macroscopic properties, such as surface tension ({sigma}) and contact angle ({beta}), are implemented through the fluid-fluid (G{sub {sigma}}) and fluid-solid (G{sub t}) interaction potentials. The model is found to express a linear relation between the macroscopic properties ({sigma}, {beta}) and microscopic parameters (G{sub {sigma}}, G{sub t}). The simulation results on bubble departure diameter appear to have the same parametric dependence as the empirical correlation. Hydrodynamic aspects of two-phase flow regime transition mechanism are investigated for different surface-coolant configurations. Results of the LB simulation clearly demonstrate that not only the bubble nucleation site density (related, e.g. to ...

2001-02-01

28

Emergency core cooling system  

International Nuclear Information System (INIS)

Purpose: To obtain stabilized operation by preventing over heat in emergency cooling pumps upon accidents of flow regulators. Constitution: A pressure suppression chamber pool and a pressure vessel are communicated to each other with a pipeway and the water in the suppression pool is charged by a charging pump to the pipeway. The pipeway is interposed with an emergency cooling pump so as to feed water in the pipeway to the pressure vessel and a water source and the emergency cooling pumps are connected by way of a closed pipeway. Further, the closed pipeway and the pipeway interposed with the charging pump are communicated to each other by way of a connecting pipeway, to which are interposed an instrument for detecting the increase in the temperature of the emergency cooling pumps due to abnormality in the closed pipe (such as troubles in flow regulators) and outputting control ...

29

The Performance Evaluation of a Hot Water Layer using a Numerical Simulation  

International Nuclear Information System (INIS)

Most of all research reactors are immerged in the deep water pool to be a ultimate heat sink. At the neighbor of the reactor, some radio-active matters, such as Na-24, Ar-41, Mg-27, Al-28 and etc, may be generated by the neutron irradiation. Those radio-active isotopes may rise up to the pool water surface through the natural convection flow, which can make the radioactivity in the reactor hall rise high enough to concern about the health of people working in the reactor hall. When the irradiation test facilities are loaded or unloaded during a normal operation, the highly radio-activated primary coolant may flow out through the irradiation test holes on the top of the reactor. This also may be a main hazard source to make the working environment of the reactor hall bad. Making a hot water layer 1.5 ? 2.0 m thick at the top of reactor pool would be a good ...

2009-05-01

30

Effect of ultrasonic waves on boiling heat transfer. 2  

International Nuclear Information System (INIS)

This report focuses on a better understanding of the physical phenomenon related to the enhancement of boiling and non-boiling heat transfer by applying ultrasonic waves. Experimental results obtained both in a pool of water and in a vertically upward water flow proved clearly that macroscopic acoustic steam induced by ultrasonics is a major contribution to heat transfer augmentation. (author).

1993-05-01

31

Effect of ultrasonic waves on boiling heat transfer  

Energy Technology Data Exchange (ETDEWEB)

This report focuses on a better understanding of the physical phenomenon related to the enhancement of boiling and non-boiling heat transfer by applying ultrasonic waves. Experimental results obtained both in a pool of water and in a vertically upward water flow proved clearly that macroscopic acoustic stream induced by ultrasonics is a major contribution to heat transfer augmentation. (author).

1993-07-01

32

Isolation condenser passive cooling of a nuclear reactor containment  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a nuclear system comprising a containment airspace in which a nuclear reactor pressure vessel is disposed there being a reactor core within the pressure vessel. It comprises a heat exchanger elevated a distance above the pressure vessel; a pool of water surrounding the heat exchanger; means for venting the pool of water to an environment outside the containment; a heat exchanger entry conduit within the containment, the entry conduit having an open lower end communicating with the containment space, and an upper end connected to the heat exchanger, water-containing heated fluid present in the containment airspace incident a pressure vessel loss of coolant event entering and flowing through the entry conduit into the heat exchanger for cooling the fluid to convert water vapor therein to a condensate and separate non-condensable gasses ...

1991-10-22

33

Safety analysis practices for the dense storage of RBMK spent fuel and improved technology for the long term storage of spent fuel in water pools  

International Nuclear Information System (INIS)

The paper discusses the safety problems connected with the conversion to dense storage of RBMK-1000 spent fuel in reactor cooling pools and independent storage facilities. Recourse to dense storage has been made for a number of reasons, among which are the absence of spent fuel shipments from the nuclear power plant site, prolongation of storage time and a partial change in storage conditions. Increasing the storage density per unit volume of the storage facility and turning to new technical procedures (as against the basic design) call for further investigation of safety problems. The safety assessment of the dense storage mode includes: (1) Selecting a list of initiating events for design basis and unforeseeable accidents; (2) Assessing dense storage safety under normal as well as design basis accident conditions; (3) Safety analysis and development of measures to compensate for unforeseen accidents. Based on the studies performed, suggestions have been advanced ...

1995-08-01

34

Origin of salinity in produced waters from the Palm Valley gas field, Northern Territory, Australia  

Energy Technology Data Exchange (ETDEWEB)

The chemical composition and evolution of produced waters associated with gas production in the Palm Valley gas field, Northern Territory, has important implications for issues such as gas reserve calculations, reservoir management and saline water disposal. The occurrence of saline formation water in the Palm Valley field has been the subject of considerable debate. There were no occurrences of mobile water early in the development of the field and only after gas production had reduced the reservoir pressure, was saline formation water produced. Initially this was in small quantities but has increased dramatically with time, particularly after the initiation of compression in November 1996. The produced waters range from highly saline (up to 300,000 mg/L TDS), with unusual enrichments in Ca, Ba and Sr, to low salinity fluids that may represent condensate ...

2005-04-01

35

Origin of salinity in produced waters from the Palm Valley gas field, Northern Territory, Australia  

International Nuclear Information System (INIS)

The chemical composition and evolution of produced waters associated with gas production in the Palm Valley gas field, Northern Territory, has important implications for issues such as gas reserve calculations, reservoir management and saline water disposal. The occurrence of saline formation water in the Palm Valley field has been the subject of considerable debate. There were no occurrences of mobile water early in the development of the field and only after gas production had reduced the reservoir pressure, was saline formation water produced. Initially this was in small quantities but has increased dramatically with time, particularly after the initiation of compression in November 1996. The produced waters range from highly saline (up to 300,000 mg/L TDS), with unusual enrichments in Ca, Ba and Sr, to low salinity fluids that may represent condensate ...

2005-04-01

36

Experience with pressuriser for PHT pressure control in TAPP 4 reactor  

International Nuclear Information System (INIS)

In a 540 MWe PHWR reactor at TAPP-4 the pressuriser has been incorporated in the PHT pressure control system to provide the necessary vapour cushion for PHT main circuit to reduce pressure variations due to transients involving swell and shrinkage. Need for the Pressuriser is due to the large inventory in PHT main circuit and relatively large heat source. The incorporation of Pressuriser is one of the modifications while upgrading from prevalent operating 220 MWe reactors to the present 540 MWe at TAPP-4. The sizing, design and selection of the 540 MWe Pressuriser has been done w.r.t swell/shrinkage requirement during normal/transient operation of the reactor. In this paper the commissioning and operating experience of the Pressuriser in conjunction with the PHT pressure control system is presented. During light water commissioning of PHT circuit some major hurdles like failure of pressuriser heaters due to faulty instrumentation were faced. ...

2006-11-13

37

FFTF reactor immersion heaters. Revision 1  

Energy Technology Data Exchange (ETDEWEB)

This specification establishes requirements for design, testing, and quality assurance for electric heaters that will be used to maintain primary Sodium temperature in the Fast Test Facility (FFTF) reactor vessel. The Test Specification (WHC-SD-FF-SDS-003) has been revised to Rev. 1. This change modifies the fabrication of approximately 25 feet of the subject heater using ceramic insulators over the heater lead wire rather than compressed magnesium oxide. Also, 304 or 316 stainless steel can be used for the heater sheath. This change should simplify fabrication and improve the heater operational reliability.

1994-08-26

38

Serviceability of steam generators at NPPs with reactors of the WWER-440 and WWER-1000 types  

Energy Technology Data Exchange (ETDEWEB)

Steam generators (SG) are the weak link of nuclear power plants, their service life is shorter than the service life of other NPP components. This paper is dedicated to a statistical analysis of SG damages and failures. Heat exchanging tubes (HET) are the most damaged elements in SG, there are on average 286 plugged or repaired tubes in each operating SG. The usually mechanisms of tube failure are the following: denting, corrosion at tube outside, pitting, fretting, and circular crack propagation. Most of damages are located in the transition zone above a tube plate. This study shows that the factors that are involved in the SG HET fault probability are: - design features of SG and secondary equipment elements (high pressure feed heaters (HPFH), low pressure feed heater (LPFH)), - water chemistry at different points of condensate feed pipe, composition and density of deposits on HET surface, efficiency of mechanical and ...

2002-07-01

39

SSHS - Departments - Taught Courses - Undergraduate Prospectus - Loughborough University  

Wastenet

... Indoor facilities include a 50 metre swimming pool, various sports halls, a netball and badminton centre, a dance studio, a high performance athletics centre, the ECB National Cricket Academy, and the National Gymnastics Performance and Research Centre, whilst outdoors there are floodlit all-weather areas, a water-based ...

40

Markets for clean energy  

Wastenet

... The products can be categorised as glazed flat-plate collectors, evacuated glass-tube collectors, and unglazed plastic or low temperature collectors. Glazed flat-plate collectors and vacuum tubes are widely used for solar water heating and space heating systems in all types of buildings. Unglazed plastic collectors are used exclusively for lower temperature applications, such as outdoor swimming pools or the agrarian business. Flat-plate solar collectors are likely to ...

41

Studies on the breeding habitats of the vector mosquito Anopheles baimai and its relationship to malaria incidence in Northeastern region of India  

British Library Electronic Table of Contents (United Kingdom)

Entomological survey was conducted to know the breeding habitat preference of the forest breeder malaria vector Anopheles baimaii, known earlier as An. dirus species D in the northeastern region of India. Breeding potential of the vector in forest areas was found to be high in water stored in jungle pool (69.84%) followed by elephant footprints with clear water (39.13%) and with turbid water (26.19%), whereas in forest fringe areas, the vector breeding was more prominent in elephant footprints: 65.11% in clear water and 62.5% in turbid water. Although other habitats had shown only low breeding of the vector, all types of habitats were positively correlated with malaria occurrence. Cattle hoof marks (r?=?0.998) and elephant footprint (turbid; r?=?0.999) explained nearly the same amount of v...

2010-01-01

42

Feasibility of maintaining natural convection mode core cooling in research reactor power upgrades  

International Nuclear Information System (INIS)

Two operational concerns for natural convection coooled research reactors using plate type fuels are: 1) pool top "1"6N activity (PTNA), and 2) nucleate boiling in core channels. The feasibility assessment of a power upgrade while maintaining natural convection mode core cooling requires addressing these operational concerns. Previous studies have shown that: a) The conventional technique for reducing PTNA by plume dispersion may not be effective in a large power upgrade of research reactors with small pools. b) Currently used correlations to predict onset of nucleate boiling (ONB) in thin, rectangular core channels are not valid for low-velocity, upward flows such as encountered in natural convection cooling. The PTNA depends on the velocity distribution in the reactor pool. COMMIX-1A code is used to determine the three-dimensional velocity fields in The Ohio State University Research Reactor (OSURR) ...

1988-05-01

43

The use of the isotope "3"2P in the study of some ecological aspects of a laboratory stream ecosystem  

International Nuclear Information System (INIS)

A laboratory stream consisting of two stream sections interrupted by two pools was filled with a mixture of tap water and organically enriched water from rivers nearby. Bottom sediment material, Potamogeton pectinatus, macro-invertebrate organisms, as well as the mosquito fish, Aplocheilichthys johnstonii were collected from rivers around Johannesburg and introduced into the laboratory stream. After initial acclimatization, the distribution of the isotope "3"2P through this laboratory stream was followed. Absorption of this isotope by benthic algae, Potamogeton pectinatus, several macro-invertebrate organisms as well as Aplocheilichthys johnstonii was recorded.

44

Final report for the DOE Suede Project, (solar utilization/economic development and employment project)  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this solar energy project was to design, manufacture, install, maintain and evaluate solar heating systems in order to stimulate community acceptance of the practicality of solar applications, reduce non-renewable energy resource consumption, and decrease residential expenditures for energy. The project also provided skill training and experience for CETA employees in the design, manufacture, and installation of solar energy equipment systems. CDC's contract had four separate solar energy projects; namely: Domestic Water Heating Systems for four Single-Family Homes; Domestic Water Heating for an industrial building; Domestic Water Heating for a (4) unit apartment complex (includes (12) supplemental space heating units); and Integral Passive Water Heaters and Energy Conservation Devices for (8) one bedroom homes. CDC staff designed all solar systems and CETA ...

1983-10-19

45

Subcooled Flow Boiling in a Minichannel  

British Library Electronic Table of Contents (United Kingdom)

It has been considered that dry-out occurs easily in boiling heat transfer for a small channel, a mini- or microchannel, because the channel was easily filled with coalescing vapor bubbles. In the present study, the experiments of subcooled flow boiling of water were performed under atmospheric conditions for a horizontal rectangular channel for which the size is 1 mm height and 1 mm width, with a flat heating surface of 10 mm length and 1 mm width placed on the bottom of the channel. The heating surface has a top of copper heating block and is heated by ceramic heaters. In the high heat flux region of nucleate boiling, about 70-80% of the heating surface was covered with a large coalescing bubble and the boiling reached critical heat flux as observed by high-speed video. In the beginning ...

2011-01-01

46

Bioreactors  

Energy Technology Data Exchange (ETDEWEB)

Composting is once again gaining interest among ecological engineers in view of greener industrial and residential activities. Uniform composting is needed to ensure decomposition and to keep the whole system at the same composting stage. A homogeneous temperature must be maintained throughout the media. A bioreactor design consisting of a heater core made of copper tubing was designed and tested. Two four-inch holes were made at the top and bottom of the barrel to allow air to flow through the system and promote aerobic composting. Once composting began and temperature increased, the water began to flow through the copper piping and the core heat was distributed throughout the medium. Three thermocouples were inserted at different heights on a 200 litre plastic barrel fitted with the aforementioned apparatus. Temperature variations were found to be considerably lower when the apparatus was operated with the heat redistribution system, enabling ...

2010-07-01

47

Aerogels: the leading edge in thermal insulation  

Energy Technology Data Exchange (ETDEWEB)

Banning CFCs in foamed insulations has led to an intensive search for alternatives which do not incur the penalty of increased thickness. The most promising of these are silica aerogels, which have proven to be the leading material, when it comes to thermal insulation and environmental protection. Refrigerators insulated with aerogels have been tested and compared to conventionally insulated ones. Results showed a substantial contribution to the energy performance. Boiler manufacturers using aerogel have been able to reduce energy consumption of water heaters by 20%. Float glass elements evacuated and filled with aerogel as well as aerogel insulated polyester lightwalls and bubble skylights yield excellent U-values and significantly reduced energy losses in buildings. (author)

1995-01-01

48

A study of binary mixture boiling: boiling site density and subcooled heat transfer  

Energy Technology Data Exchange (ETDEWEB)

(Boiling site densities and heat-transfer coefficients have been measured for ethanol-water and ethanol-benzene mixtures at 1.01 bar for a heated vertical brass disk. A strong effect of composition on the boiling site density was observed, which was attributed to the nature of the activation of the boiling surface and mass diffusion effects. The boiling heat-transfer coefficient was found to decrease with increasin subcooling, but for the mixtures at a given level of subcooling the decrease was less than that for the single components and azeotropic mixtures.) The heat-transfer coefficient at a given heat flux was seen to be quite insensitive to the very large increase in boiling site density in comparing the pure water and the ethanol-water azeotrope results, leading one to question pool boiling models that predict heat-transfer rates on the basis of boiling site density.

1985-05-01

49

The RADionuclide Transport, Removal, and Dose (RADTRAD) code  

Energy Technology Data Exchange (ETDEWEB)

The RADionuclide Transport, Removal, And Dose (RADTRAD) code is designed for US Nuclear Regulatory Commission (USNRC) use to calculate the radiological consequences to the offsite population and to control room operators following a design-basis accident at Light Water Reactor (LWR) power plants. This code utilizes updated reactor accident source terms published in draft NUREG-1465, ``Accident Source Terms for Light-Water Nuclear Power Plants.`` The code will track the transport of radionuclides as they are released from the reactor pressure vessel, travel through the primary containment and other buildings, and are released to the environment. As the radioactive material is transported through the primary containment and other buildings, credit for several removal mechanisms may be taken including sprays, suppression pools, overlying pools, filters, and natural deposition. Simple models are available ...

1993-07-01

50

Cost comparison among spent fuel storage techniques  

Energy Technology Data Exchange (ETDEWEB)

Scenarios are developed for spent fuel that is taken out of the nuclear reactor and stored for 20 years before reprocessing, and three storage techniques which use a water pool, dry cask or vault are compared with respect to their costs. The storage price (storage cost per kilogram of spent fuel), which is employed as the economic index, is calculated on the assumption that all the charge is paid when the spent fuel is brought in the storage facilities. Four scenarios are assumed for spent PWR and BWR fuels to be stored in at-reactor (AT) or away-from-reactor (AFR) facilities. The capital costs cover the buildings of the storage facilities, equipment, decommissioning, casks for transportation and storage (for cask storage) and casks for transportation (for water pool or vault storage). Costs for operation and maintenance of the facilities are also considered in evaluating these methods. Evaluation ...

1987-09-01

51

Cost comparison among spent fuel storage techniques  

International Nuclear Information System (INIS)

Scenarios are developed for spent fuel that is taken out of the nuclear reactor and stored for 20 years before reprocessing, and three storage techniques which use a water pool, dry cask or vault are compared with respect to their costs. The storage price (storage cost per kilogram of spent fuel), which is employed as the economic index, is calculated on the assumption that all the charge is paid when the spent fuel is brought in the storage facilities. Four scenarios are assumed for spent PWR and BWR fuels to be stored in at-reactor (AT) or away-from-reactor (AFR) facilities. The capital costs cover the buildings of the storage facilities, equipment, decommissioning, casks for transportation and storage (for cask storage) and casks for transportation (for water pool or vault storage). Costs for operation and maintenance of the facilities are also considered in evaluating these methods. Evaluation ...

52

Waste heat utilization in the thermal spa of Lavey-les-Bains; Etude de la valorisation des rejets thermiques des Bains de Lavey  

Energy Technology Data Exchange (ETDEWEB)

This final report for the Swiss Federal Office of Energy looks at the possibilities for improved waste water utilization in the Lavey-les-Bains thermal spa, Switzerland. According to the regulations in force, the temperature of the waste water rejected into the Rhone river shall not exceed 30 {sup o}C, what is currently not the case. Also the operational cost shall be reduced and the waste water quality improved. The installations are presented. From the two geothermal wells, mineral water comes out at an average flow rate of 940 l/min and a temperature of 63 {sup o}C. Actual waste water data are reported. The measured thermal water consumption data, including seasonal variations, are analysed by computerized simulation and measures to reduce the consumed volume by the optimization of internal procedures are evaluated. Measures to reduce the quantity of the ...

2004-07-01

53

Waste heat utilization in the thermal spa of Lavey-les-Bains  

International Nuclear Information System (INIS)

This final report for the Swiss Federal Office of Energy looks at the possibilities for improved waste water utilization in the Lavey-les-Bains thermal spa, Switzerland. According to the regulations in force, the temperature of the waste water rejected into the Rhone river shall not exceed 30 "oC, what is currently not the case. Also the operational cost shall be reduced and the waste water quality improved. The installations are presented. From the two geothermal wells, mineral water comes out at an average flow rate of 940 l/min and a temperature of 63 "oC. Actual waste water data are reported. The measured thermal water consumption data, including seasonal variations, are analysed by computerized simulation and measures to reduce the consumed volume by the optimization of internal procedures are evaluated. Measures to reduce the quantity of the rejected free ...

54

Marine pastures: a by-product of large (100 megawatt or larger) floating ocean thermal power plants. Progress report, February 1, 1976--April 30, 1976  

Science.gov (United States)

Computer programs have been developed to define the temperature increase which would be needed to bring deep-ocean water into density equilibrium with surface water for locations where data are available. A series of continuous-flow studies on phytoplankton blooms resulting from mixtures of 80 percent deep and 20 percent surface water in 2000-liter concrete culturing vessels (''reactors'') has been completed. A quantitative determination of nutrient utilization and flow through a combined primary and secondary trophic level system has been completed. This study utilized the clam Tapes semidecussata, fed from phytoplankton grown in 80 percent deep and 20 percent surface water. An analysis of the fate of the deep water discharged from a floating OTEC plant indicates that horizontal containment of the resulting deep water: ...

1976-01-01

55

NATURAL GAS VARIABILITY IN CALIFORNIA: ENVIRONMENTAL IMPACTS AND DEVICE PERFORMANCE EXPERIMENTAL EVALUATION OF POLLUTANT EMISSIONS FROM RESIDENTIAL APPLIANCES  

Science.gov (United States)

The effect of liquefied natural gas on pollutant emissions was evaluated experimentally with used and new appliances in the laboratory and with appliances installed in residences, targeting information gaps from previous studies. Burner selection targeted available technologies that are projected to comprise the majority of installed appliances over the next decade. Experiments were conducted on 13 cooktop sets, 12 ovens, 5 broiler burners, 5 storage water heaters, 4 forced air furnaces, 1 wall furnace, and 6 tankless water heaters. Air-free concentrations and fuel-based emission factors were determined for carbon monoxide, nitrogen oxides, nitrogen dioxide, and the number of (predominantly ultrafine) particles over complete burns?including transient effects (device warm-up and intermittent firing of burners) following ignition--and during more stable end-of-burn conditions. Formaldehyde was measured ...

2009-12-01

56

Upper Paleozoic petroleum system, Ordos Basin, China  

Energy Technology Data Exchange (ETDEWEB)

The Ordos Basin is a typical lapped basin, including three sequences of strata: early Paleozoic, late Paleozoic and Mesozoic, with a total thickness of 4000-6000m. Impermeable sealing beds are well developed at the top and base of the upper Paleozoic sequence, separating it from the Mesozoic and the lower Paleozoic strata to form an independent petroleum system. In this petroleum system, the source rocks are widely distributed coals and dark mudstones occurring in the Carboniferous-lower Permian coal measures, with a thickness of 10-15 and 40-60m, respectively. The reservoirs are mainly early Permian tight sandstones, mostly with a porosity of 4-8% and a permeability of 0.1-1.0x10{sup -3}{mu}m{sup 2}. The regional cap rock is a 100-150m thick mudstone in the upper Permian strata. The structural framework of the basin is a huge asymmetric syncline, dipping gently toward the east and north, and steeply toward the south and west. Well data show that gas-saturated, ...

2005-09-01

57

Employing exergy-optimized pin fins in the design of an absorber in a solar air heater  

Energy Technology Data Exchange (ETDEWEB)

Fins serve as heat transfer augmentation features in solar air heaters; however, they increase pressure drop in flow channels. Pin fins are relatively good heat transfer augmentation features with superior aerodynamic performance, and as a result find application in some solar air heaters. The exergy optimization method is employed in sizing the pin fin. Results indicate that high efficiency of the optimized fin improves the heat absorption and dissipation potential of a solar air heater. With optimum fin efficiency and superior absorptive coating quality, useful energy losses can be minimized. Some important observations pertinent in design are made. (author)

2010-02-15

58

PROBING NEAR-SURFACE ATMOSPHERIC TURBULENCE WITH LIDAR MEASUREMENTS AND HIGH-RESOLUTION HYDRODYNAMIC MODELS  

Energy Technology Data Exchange (ETDEWEB)

As lidar technology is able to provide fast data collection at a resolution of meters in an atmospheric volume, it is imperative to promote a modeling counterpart of the lidar capability. This paper describes an integrated capability based on data from a scanning water vapor lidar and a high-resolution hydrodynamic model (HIGRAD) equipped with a visualization routine (VIEWER) that simulates the lidar scanning. The purpose is to better understand the spatial and temporal representativeness of the lidar measurements and, in turn, to extend their utility in studying turbulence fields in the atmospheric boundary layer. Raman lidar water vapor data collected over the Pacific warm pool and the simulations with the HIGRAD code are used for identifying the underlying physics and potential aliasing effects of spatially resolved lidar measurements. This capability also helps improve the trade-off between spatial-temporal resolution ...

2000-11-01

59

Instabilities during liquid migration into superheated hydrothermal systems  

Energy Technology Data Exchange (ETDEWEB)

Hydrothermal systems typically consist of hot permeable rock which contains either liquid or liquid and saturated steam within the voids. These systems vent fluids at the surface through hot springs, fumaroles, mud pools, steaming ground and geysers. They are simultaneously recharged as meteoric water percolates through the surrounding rock or through the active injection of water at various geothermal reservoirs. In a number of geothermal reservoirs from which significant amounts of hot fluid have been extracted and passed through turbines, superheated regions of vapor have developed. As liquid migrates through a superheated region of a hydrothermal system, some of the liquid vaporizes at a migrating liquid-vapor interface. Using simple physical arguments, and analogue laboratory experiments we show that, under the influence of gravity, the liquid-vapor interface may become unstable and break up into fingers.

1995-01-26

60

Beverage iodine levels in Germany  

British Library Electronic Table of Contents (United Kingdom)

Sales of iodized table salt (household use, bulk containers) have been flat in Germany since 1996/1997. Nevertheless, the amount of iodide excreted with the urine has been steadily increasing in the German population since 1993. We investigated the beverage iodine levels as possible source of the increased input of iodine into the food chain. No systematic studies on this topic have yet been carried out in Germany. A total of 510 samples were drawn from large grocery discounters who supply all German states with their products (35% fruit and vegetable juices, 35% beers, 10% pooled milk and yoghurt drinks, 10% mineral water, 10% soda). (1) Water-based beverage samples are prepared by solid-phase extraction and iodine concentration is determined by HPLC and electrochemical detection, (2) the...

2009-01-01

61

Start-up control system and vessel for LMFBR  

Energy Technology Data Exchange (ETDEWEB)

A reflux condensing start-up system includes a steam generator, a start-up vessel connected parallel to the steam generator, a main steam line connecting steam outlets of the steam generator and start-up vessel to a steam turbine, a condenser connected to an outlet of the turbine and a feedwater return line connected between the condenser and inlets of the steam generator and start-up vessel. The start-up vessel has one or more heaters at the bottom thereof for heating feedwater which is supplied over a start-up line to the start-up vessel. Steam is thus generated to pressurize the steam generator before the steam generator is supplied with a heat transfer medium, for example liquid sodium, in the case of a liquid metal fast breeder reactor. The start-up vessel includes upper and lower bulbs with a smaller diameter mid-section to act as water and steam reservoirs. The start-up vessel can thus be used not only in a start-up operation but as a ...

1987-01-01

62

Power-cycle studies for a geothermal electric plant for MX operating bases  

Energy Technology Data Exchange (ETDEWEB)

Binary geothermal plants were investigated for providing electrical power for MX missile bases. A number of pure hydrocarbons and hydrocarbon mixtures were evaluated as working fluids for geothermal resource temperatures of 365, 400, and 450/sup 0/F. Cycle thermodynamic analyses were conducted for pure geothermal plants and for two types of coal-geothermal hybrid plants. Cycle performance results were presented as net geofluid effectiveness (net plant output in watts per geofluid flow in 1 bm/hr) and cooling water makeup effectiveness (net plant output in watts per makeup water flow in 1 bm/hr). A working fluid containing 90% (mass) isobutane/10% hexane was selected, and plant statepoints and energy balances were determined for 20MW(e) geothermal plants at each of the three resource temperatures. Working fluid heaters and condensers were sized for these plants. It is concluded that for the advanced plants investigated, ...

1981-11-01

63

The RADionuclide transport, removal, and dose (RADTRAD) code  

International Nuclear Information System (INIS)

The RADionuclide Transport, Removal, And Dose (RAD-TRAD) code is designed for U.S. Nuclear Regulatory Commission (USNRC) use to calculate the radiological consequences to the off-site population and to control room operators following a design-basis accident at light water reactor (LWR) power plants. This code utilizes updated reactor accident source terms published in draft NUREG-1465. The code will track the transport of radionuclides as they are released from the reactor pressure vessel, travel through the primary containment and other buildings, and are released to the environment. As the radioactive material is transported through the primary containment and other buildings, credit for several removal mechanisms may be taken, including sprays, suppression pools, overlying pools, filters, and natural deposition. Simple models are available for these different removal mechanisms that use, as input, information about the ...

1993-11-14

64

Environmental fate and distribution of technetium-99 in a deciduous forest ecosystem  

International Nuclear Information System (INIS)

The uptake of "9"9Tc by trees intercepting contaminated groundwater from a radioactive waste storage site was measured to identify the major "9"9Tc pools within the woodland ecosystem and to assess the relative mobility of "9"9Tc in the existing element cycle. The highest average "9"9Tc concentrations in vegetation were found in herbaceous plants. Tree wood was the major above-ground pool for "9"9Tc because of the high concentrations in wood as well as the large amount of wood relative to other biomass at the site. Technetium was not easily leached from the trees by rainfall and was not readily extractable from forest floor leaf litter by water. The relative importance of return pathways for "9"9Tc to the forest floor was leaf fall > stemflow > throughfall, indicating that "9"9Tc was conserved by the trees. Snails and millipedes from the leaf litter layer concentrated technetium 20- and 16-fold, respectively, above ...

65

Burnup determination of spent nuclear fuel in the pool  

Energy Technology Data Exchange (ETDEWEB)

A algorithm was developed to determine the characteristic parameters of PWR spent fuel, such as burnup, cooling time and initial enrichment of {sup 235}U by use of gamma-ray activity ratios of {sup 134}Cs/{sup 137}Cs, {sup 154}Eu/{sup 137}Cs and {sup 106}Ru/{sup 137}Cs from the high resolution gamma-ray spectroscopy and ORIGEN-S calculations. For the verification of the method developed, gamma-ray measurements of Kori-1 and Kori-2 nuclear fuel rods were carried out using HPGe gamma ray scanning system. As a results, it is revealed that the measured values are in a good agreement with the operator declared values within the about {+-} 5% errors. Besides, the under-water burnup measuring device has been designed to measure the gamma-ray from the PWR spent fuel assembly. This device will be set up in the pool of Post-Irradiation Examination Facility(PIEF), and used in determination of the average burnup, cooling time and initial enrichment of the ...

1998-06-01

66

Self-construction of a solar water heater; Calentador solar de agua de auto-construccion  

Energy Technology Data Exchange (ETDEWEB)

In this work a flat receiver of self construction is shown with relatively low cost and easy manufacture, but with a thermal efficiency superior to 40% for applications at temperatures less than 60 degrees Celsius, that allows satisfying international standards in this respect. The heater has been matter of study in open courses distributed in the Universidad Autonoma de la Ciudad de Mexico (UACM) oriented to that the participants construct their own system, in addition to its installation and tests. The obtained results have been excellent. The massive use of efficient solar receivers of self-construction can truly help to the decreasing of the gas discharges of greenhouse effect. [Spanish] En este trabajo se presenta un captador plano de auto construccion con relativamente bajo costo y facil manufactura, pero con un rendimiento termico superior a 40% para aplicaciones a temperatura menos de 60 grados centigrados que le permite satisfacer estandares ...

2009-07-01

67

Pollutant Emission Factors from Residential Natural Gas Appliances: A Literature Review  

Energy Technology Data Exchange (ETDEWEB)

There is a need to reduce air pollutant emissions in some U.S. urban regions to meet federal and state air quality guidelines. Opportunities exist for reducing pollutant emissions from natural gas appliances in the residential sector. A cost-benefit analysis on various pollutant-reducing strategies is needed to evaluate these opportunities. The effectiveness of these pollutant-reducing strategies (e.g., low-emission burners, energy conservation) can then be ranked among themselves and compared with other pollutant-reducing strategies available for the region. A key step towards conducting a cost-benefit analysis is to collect information on pollutant emissions from existing residential natural gas appliances. An extensive literature search was conducted to collect data on residential natural-gas-appliance pollutant emission factors. The literature primarily describes laboratory tests and may not reflect actual emission factor distributions in the field. Pollutant emission factors for ...

1996-08-01

68

Ground temperatures surrounding a molten fuel pool  

International Nuclear Information System (INIS)

In the analysis of the consequences of a hypothetical meltdown accident in an LMFBR, it is important to estimate the final location of the molten fuel pool in the concrete and ground underlying the reactor vessel. The GROWS program and the AYER program have been developed to calculate the final location of the molten fuel pool as the culmination of the transient analysis of this unusual Stefan problem but these programs require extensive computational resources. The solution is provided to the concrete and ground temperatures surrounding the stationary fuel pool and the related heat flux from the pool to the ground surface outside the containment building. This solution can be used to estimate the final location of the fuel pool and to check the end results of the sophisticated programs.

1977-06-01

69

Pseudomonas aeruginosa for the Evaluation of Swimming Pool Chlorination and Algicides  

UK PubMed Central (United Kingdom)

Concentrations of ammonia and the chlorine stabilizer, cyanuric acid, which could be expected in swimming pools decreased the rate of kill by chlorine of the potential pathogen, Pseudomonas...Full Text Available

1969-03-01

70

Factors Influencing the Effectiveness of Swimming Pool Bactericides  

UK PubMed Central (United Kingdom)

Techniques for culturing, harvesting, and testing bacteria to evaluate bactericidal chemicals for swimming pools are described. Concentrations of 25, 50, and 100 mg of the chlorine stabilizer cyanuric...Full Text Available

1967-05-01

71

Preparation of AgBr Nanoparticles in Microemulsions Via Reaction of AgNO{sub 3} with CTAB Counterion  

Energy Technology Data Exchange (ETDEWEB)

Nanoparticles of AgBr were prepared by precipitating AgBr in the water pools of microemulsions consisting of CTAB, n-butanol, isooctane and water. An aqueous solution of AgNO{sub 3} added to the microemulsion was the source of Ag{sup +} ions. The formation of AgBr nanoparticles in microemulsions through direct reaction with the surfactant counterion is a novel approach aimed at decreasing the role of intermicellar nucleation on nanoparticle formation for rapid reactions. The availability of the surfactant counterion in every reverse micelle and the rapidity of the reaction with the counterion trigger nucleation within individual reverse micelles. The effect of the following variables on the particle size and size distribution was investigated: the surfactant and cosurfactant concentrations, moles of AgNO{sub 3} added, and water to surfactant mole ratio, R. High concentration of the surfactant or ...

2007-10-15

72

First oil expected at White Rose in 2005  

Energy Technology Data Exchange (ETDEWEB)

Husky Oil received approval from the government to begin development of its White Rose properties located in the Jean d'Arc Basin, 350 km east of St. John's, offshore Newfoundland and Labrador. First oil is expected by the end of 2005. The South Avalon Pool was discovered in 1988 and is estimated to contain approximately 200-250 million barrels of oil. Husky Oil and Petro-Canada filed a development application with the Canada-Newfoundland Offshore Petroleum Board in January 2001. Approval of the $2.35 billion project was received in December 2001. The development plan is based on a newly-built floating production, storage and offloading (FPSO) vessel. Initial development will focus on the South Avalon Pool that has been tested in excess of 5,000 barrels per day. The pool will be developed using eight production wells, 11 water injection wells and two gas injection wells. An estimated ...

2002-04-01

73

Temperature control by telephone; Temperatuurinstelling wijzigen via de telefoon  

Energy Technology Data Exchange (ETDEWEB)

A brief overview is given of the developments with regard to the ease of operation of water heaters in houses, in particular the option to use remote control (e.g. the telephone) to adjust the temperature. [Dutch] Woonkwaliteit betekent voor de meeste mensen een combinatie van luxe, comfort en gemak. Vertaald naar ons vakgebied, houdt dat onder andere in: luxe badkamers met bijvoorbeeld massagedouches, waarvoor grote volumestromen warmtapwater benodigd zijn, een comfortabel binnenklimaat en een stuk bedieningsgemak om een en ander te realiseren. Nu is Nederland een uitgesproken combiketel land, waarbij de ketel over het algemeen met behulp van eenvoudige (klok)thermostaten wordt geregeld. Onze Oosterburen kiezen veel vaker voor separate ketel-boilercombinaties voor een groot warmtapwater comfort en uitgebreide regelapparatuur voor de (ruimte)temperatuurregeling. Maar ook in Nederland neernt de vraag naar meer warmwater toe en worden steeds ...

2003-10-01

74

Pseudocleopatra bennikei  

Science.gov (United States)

... Zaire River, near Kinshasa (Stanley Pool) and near Matadi (Kala Kala). It is possibly present between the ... ...

76

Condition of research reactor spent nuclear fuel in wet storage  

International Nuclear Information System (INIS)

The condition of spent nuclear fuel (SNF) in wet storage at ten Soviet-designed research reactors has been assessed in the light of international experience in order to identify any associated safety issues. These reactors use Al-clad UO2-Al or U-Al alloy dispersion fuels of ?20% enrichment that were fabricated in Russia; the reactors have been in operation since 1955-70. Although originally sent for reprocessing, much of the SNF generated over the last 25-30 years has been stored in fuel storage pools (FSPs) of variable water quality. The external condition of wet-stored SNF assemblies from the reactors surveyed varied from significant failure due to galvanic corrosion that was driven by poor water quality, through gradual pitting caused by slightly impure water, to a stable condition of no observable change in the oxidized Al alloy surface of the irradiated fuel. SNF stability in wet storage seems to ...

2004-10-01

77

Void fraction distribution measurement in two-phase flow by real-time neutron radiography and real-time image processing  

International Nuclear Information System (INIS)

A real-time two-dimensional void fraction distribution measurement of gas-liquid two-phase flow was carried out by real-time neutron radiography and real-time image processing. The JRR-3M real-time thermal neutron radiography system and a Musashi dynamic image processing system were used. Image processing methods to calculate two-dimensional and cross-sectional void fraction distributions were proposed. The void fraction distribution was calculated by non-linear processing of the neutron radiography image and displayed by pseudo-color in real-time. A simple gas-liquid two-phase flow induced by injecting gas through needles at the bottom of water pool in a rectangular vessel was tested. (orig.).

1996-07-01

78

Heat and mass transfer analogy studies of binary liquid mixture in comparison with ethanol-n-heptane evaporating to air  

Energy Technology Data Exchange (ETDEWEB)

An experimental and theoretical study of heat and mass transfer analogy and a comparison of that to a binary liquid mixture evaporation is presented. Common organic solvents, ethanol and n-heptane, were used to form an alcohol - hydrocarbon mixture. Studies were carried out in a horizontal rectangular channel having air flow velocities of 0.2 - 0.9 m/s. Heat transfer coefficients were measured with a copper plate resistor and mass transfer coefficients with a square pool. The heat and mass transfer analogy is presented for a system having two evaporating compounds with a fixed value of air flow and verified by measuring and comparing mass transfer coefficients for distilled water with air flow velocities of 0.2 - 0.9 m/s. An illustrative example of the use of the theory for industrial ventilation is presented. (author)

1995-12-31

79

A new approach to the isolation and characterization of wheat flour allergens  

British Library Electronic Table of Contents (United Kingdom)

Summary Background The incidence of food allergy to wheat is increasing. Its diagnosis depends on the purity of major allergens and their inclusion in tests. Isolation and characterization of wheat allergens are therefore of utmost importance. Objective To purify and identify wheat flour allergens most frequently recognized by patients' IgE antibodies and to study their allergenicity. Methods Water/salt-soluble extracts from wheat flour were prepared and separated using a combination of ultrafiltration, isoelectric focusing and liquid chromatography. Purified proteins were analysed by immunoblotting using pooled sera from patients with atopic dermatitis who possessed IgE specific to wheat. Wheat proteins found to bind IgE were subsequently identified by matrix-assisted laser desorption/ion...

2011-01-01

80

Tantalum capping on platinum thin heater for selective area heating  

Energy Technology Data Exchange (ETDEWEB)

The thermal radiation which generated from the patterned Ta/Pt/Ta thin heater achieved a high temperature up to 1010 {sup o}C under applied current of 2.4 A. In order to reduce an electromigration at high current of 2 A, a Ta capping layer was placed on the Pt layer instead of conventional capping layer, such as SiNx and CoWP. Under the thermal radiation at the applied current of 2 A in the Ta/Pt/Ta thin heater, the Ta capping layer enhanced the lifetime of the Pt thin heater up to 5 h. A stamping process for the crystallization of a-Si was performed for 40 samples using the Ta/Pt/Ta thin heater. For all samples, a-Si has been selectively crystallized and Raman peaks were located near 519 cm{sup -} {sup 1}. These results indicated that the thermal radiation of the Ta/Pt/Ta thin heater was maintained constantly due to the Ta capping.

2009-05-29

81

Safety System Design Concept and Performance Evaluation for a Long Operating Cycle Simplified Boiling Water Reactor  

Science.gov (United States)

The long operating cycle simplified boiling water reactor is a reactor concept that pursues both safety and the economy by employing a natural circulation reactor core without a refueling, a passive decay heat removal, and an integrated building for the reactor and turbine. Throughout the entire spectrum of the design basis accident, the reactor core is kept covered by the passive emergency core cooling system. The decay heat is removed by the conventional active low-pressure residual heat removal system. As for a postulated severe accident, the suppression pool water floods the lower part of the reactor pressure vessel (RPV) in the case when core damage occurs, and the in-vessel retention that keeps the melt inside the RPV is achieved by supplying the coolant. The containment adopts a parallel-double-steel-plate structure similar to a hull structure, which contains coolant between the inner and outer walls to absorb the ...

2003-07-15

82

Two-phase flow instabilities in a single channel with enhanced heat transfer, and pressure-drop type oscillation thresholds  

International Nuclear Information System (INIS)

In recent years, there has been increased emphasis on techniques to enhance two-phase flow heat transfer. The resulting increase in the use of heat transfer augmentation and the engineering importance of the subject presents this investigation in order to study the effect of different heater surface configurations on two-phase flow instabilities. The authors present the results of an experimental and theoretical study, summarized as: instabilities are not affected by small changes in heat transfer; nucleate boiling increases system unstability; amplitude of the oscillations increases as the axial temperature gradient over the heater increases; for the same type heater surfaces system stability increases with decreasing equivalent diameter; period of the oscillations depend on the heater surfaces; and linearized analysis and steady-state data can be used to determine the oscillation thresholds.

1985-10-01

83

RCRA closure of the Building 3001 Storage Canal  

Energy Technology Data Exchange (ETDEWEB)

The 3001 Storage Canal is located under portions of Buildings 3001 and 3019 at Oak Ridge National Laboratory (ORNL) and has a capacity of approximately 62,000 gallons of water. The term canal has historically been used to identify this structure, however, the canal is an in-ground reinforced concrete structure satisfying the regulatory definition of a tank. From 1943 through 1963, the canal in Building 3001 was designed to be an integral part of the system for handling irradiated fuel from the Oak Ridge Graphite Reactor. Because one of the main initial purposes of the reactor was to produce plutonium for the chemical processing pilot plant in Building 3019, the canal was designed to be the connecting link between the reactor and the pilot plant. During the war years, natural uranium slugs were irradiated in the reactor and then pushed out of the graphite matrix into the system of diversion plates and chutes which directed the fuel into the deep pit of the canal. ...

1992-09-01

84

Monte Carlo methods, models, and applications to the advanced neutron source  

Energy Technology Data Exchange (ETDEWEB)

This paper reports on three-dimensional continuous-energy coupled neutron-gamma Monte Carlo models of the Advanced Neutron Source (ANS) final preconceptual and conceptual reference core designs developed using the Monte Carlo Neutron and Photon transport code (MCNP) Version 3b. These models contain the reactor core with control rods, the heavy water reflector tank with shutdown rods and some beam tubes, and the outer light water pool. Eighty homogenized fuel zones per fuel element are used to represent the radial and axial {sup 235}U fuel distribution. These models are the most sophisticated, physically accurate reactor physics models of the ANS currently available. The use of MCNP methods and applications to the ANS are demonstrated. Beam tube studies, coolant voiding studies, and many criticality studies have already been performed, as have studies with variance reduction techniques. In comparison with deterministic ...

1991-09-01

85

A model for the calculation of vent clearing transients in pressure suppression systems  

International Nuclear Information System (INIS)

For the layout of a pressure suppression system of a light water cooled reactor (boiling water reactor) it is important to know the time dependent behavior of the vent clearing transient after a loss-of-coolant accident for two main reasons: time of the end of the vent clearing transient influences strongly the pressure and temperature maxima in the drywell and wetwell. Time-dependent behavior of the vent clearing transient influences pressure loads in the condensation pool of the wetwell and therefore pressure induced stresses to the structure. The time-dependent behavior of the water masses in the vent pipes and wetwell are described by the basic equations for a nonstationary incompressible friction flow: momentum equation, continuity equation and a correlation for the variation of the state of the gas volume in the wetwell above the water level. After many algebraic operations ...

1975-09-01

86

Externally fired combined cycle demonstration  

Energy Technology Data Exchange (ETDEWEB)

Externally Fired Combined Cycles (EFCCs) can increase the amount of electricity produced from ash bearing fuels up to 40%, with overall powerplant efficiencies in excess of 45%. Achieving such high efficiencies requires high temperature-high pressure air heaters capable of driving modern gas turbines from gas streams containing the products of coal combustion. A pilot plant has been constructed in Kennebunk, Maine to provide proof of concept and evaluation of system components. Tests using pulverized Western Pennsylvania bituminous coal have been carried out since April, 1995. The ceramic air heater extracts energy from the products of coal combustion to power a gas turbine. This air heater has operated at gas inlet temperatures over 1,095 C and pressures over 7.0 atm without damage to the ceramic tube string components. Stable gas turbine operation has been achieved with energy input from the air ...

1995-11-01

87

Lodging - Decommissioning Training Course - Decontamination and...  

Science.gov (United States)

Hour Fitness Center 24 Hour Market 24 Fitness Center Indoor Heated Pool with Whirlpool Seasonal Outdoor Pool Plaza w/ Outdoor Tiki Bar & Café 1,200 Square Foot Total of...

2011-10-08

88

Does adenine incorporation into nucleic acids measure total microbial production:: a response to comments by Fuhrman et al  

Science.gov (United States)

The uptake and incorporation of (/sup 3/H)adenine as a measure of total microbial (bacteria and unicellular algae) nucleic acid synthesis depends on the validity of several assumptions. A unique characteristic of the (/sup 3/H)adenine method is the ability to measure the specific radioactivity (nCi pmol/sup -1/) of the immediate precursor pool of the adenine incorporated into nucleic acids. This measurement permits correction for isotope dilution when the added radiotracer mixes with exogenous pools of structurally related compounds before uptake and with endogenous pools after transport into the cells. The immediate precursors to (/sup 3/H)adenine incorporation into cellular RNA and DNA are ATP and dATP. Since the intracellular dATP pool is in isotopic equilibrium with the ATP pool, one can determine the specific radioactivity of both precursor pools by ...

1986-11-01

89

A Multi-Method Process Evaluation for a Skin Cancer Prevention Diffusion Trial  

UK PubMed Central (United Kingdom)

This article describes process evaluation methods for the Pool Cool Diffusion Trial across four years. Pool Cool is a skin cancer prevention program that was...Full Text Available

2009-06-01

90

Safe Type of Transference for Spent Fuel  

International Science & Technology Center (ISTC)

Safe Transference of Spent Fuel Assemblies from Near-Reactor Storage Pools to Long-term "Dry" Storage

91

Evaluation of advanced technologies for residential appliances and residential and commercial lighting  

Energy Technology Data Exchange (ETDEWEB)

Section 127 of the Energy Policy Act requires that the Department of Energy (DOE) prepare a report to Congress on the potential for the development and commercialization of appliances that substantially exceed the present federal or state efficiency standards. Candidate high-efficiency appliances must meet several criteria including: the potential exists for substantial improvement (beyond the minimum established in law) of the appliance`s energy efficiency; electric, water, or gas utilities are prepared to support and promote the commercialization of such appliances; manufacturers are unlikely to undertake development and commercialization of such appliances on their own, or development and production would be substantially accelerated by support to manufacturers. This report describes options to improve the efficiency of residential appliances, including water heaters, clothes washers and dryers, refrigerator/freezers, ...

1995-01-01

92

Building a Construction Curriculum for Your School District  

Science.gov (United States)

Embracing the notion of going green, an affluent school district in Pennsylvania spent $83 million as part of the high school's renovation and expansion project. The three-level addition is now equipped with self-dimming lights, energy-efficient windows, a rooftop solar water heater, and a geothermal cooling and heating system. As a bonus for going green, the school district received a $250,000 grant from the Pennsylvania Department of Environmental Protection. The district used that money to create an information center in the lobby of the building where a touch-screen computer provides students, staff, and visitors with data related to the operation of the school's energy-efficient water and electrical systems. The system will graphically depict utility use over the course of a year. The monitoring system and touch-screen computer can turn this school into a living lab, with science, math, and economics teachers using the ...

2010-06-01

93

Feasibility of /sup 252/Cf source driven neutron noise measurements in water moderated reactors  

Energy Technology Data Exchange (ETDEWEB)

Previous experiments in fast critical assemblies demonstrated a method of determining reactivity from power spectral density measurements with /sup 252/Cf. This method determines reactivity from properties of the reactor only at the subcritical state of interest, thus it does not require a calibration near delayed criticality. The interpretation of the measured data to obtain reactivity does not require knowledge of the relative or absolute values of the source intensity, knowledge of the detection efficiencies, or knowledge of the detection instrumentation frequency responses. An experiment was performed at the Pool Critical Assembly to evaluate the possibility of /sup 252/Cf source driven neutron noise spectral density measurements in light water moderated reactors. This experiment showed that using commercially available detectors, such measurements can be performed in a reasonable time, that is, the measurement of the quantity of interest ...

1980-01-01

94

Shell Temperatures for a Single-Heater Diffuser  

Energy Technology Data Exchange (ETDEWEB)

A new diffuser/permeator design has been proposed for a new Savannah River Site tritium project. The use of a single heater well in the center of the shell had raised concerns that the Pd/Ag coils may be shielding radiative heat transfer to the walls thus reducing Pd/Ag tube temperatures near the shell below the recommended minimum operating temperature. The diffuser was fitted with thermocouples to measure shell temperatures during testing. Tests were run with the shell evacuated, helium feed flows of 0, 1000, and 2000 sccm; bleed pressures ranging from 0 to 203 kPa, and heater temperatures of 650, 675, and 700 degrees C. Hydrogen permeation tests were run with two hydrogen/helium mixtures and feed rates to simulate 1st and 2nd stage diffuser operations. Approximately 20 hours were required to bring the diffuser from ambient temperature to steady-state conditions. For tests with a heater temperature of 675 degrees C and no ...

2004-11-01

95

High-pressure ceramic air heater for indirectly fired gas turbine applications  

Energy Technology Data Exchange (ETDEWEB)

The Externally-Fired Combined Cycle (EFCC) offers a method for operating high-efficiency gas and steam turbine combined cycles on coal. In the EFCC, an air heater replaces the gas turbine combustor so that the turbine can be indirectly fired. Ceramic materials are required for the heat exchange surfaces to accommodate the operating temperatures of modern gas turbines. The ceramic air heater or heat exchanger is the focus of this program, and the two primary objectives are (1) to demonstrate that a ceramic air heater can be reliably pressurized to a level of 225 psia (1.5 MPa); and (2) to show that the air heater can withstand exposure to the products of coal combustion at elevated temperatures. By replacing the gas turbine combustor with a ceramic air heater, the cycle can use coal or other ash-bearing fuels. Numerous programs have attempted to fuel high efficiency gas turbines ...

1992-01-01

96

High-pressure ceramic air heater for indirectly fired gas turbine applications  

Energy Technology Data Exchange (ETDEWEB)

The Externally-Fired Combined Cycle (EFCC) offers a method for operating high-efficiency gas and steam turbine combined cycles on coal. In the EFCC, an air heater replaces the gas turbine combustor so that the turbine can be indirectly fired. Ceramic materials are required for the heat exchange surfaces to accommodate the operating temperatures of modern gas turbines. The ceramic air heater or heat exchanger is the focus of this program, and the two primary objectives are (1) to demonstrate that a ceramic air heater can be reliably pressurized to a level of 225 psia (1.5 MPa); and (2) to show that the air heater can withstand exposure to the products of coal combustion at elevated temperatures. By replacing the gas turbine combustor with a ceramic air heater, the cycle can use coal or other ash-bearing fuels. Numerous programs have attempted to fuel high efficiency gas turbines ...

1992-12-01

97

Multi-Dimensional Analysis for Sodium Hot Pool using MARS-LMR in Steady State  

International Nuclear Information System (INIS)

DBEs (Design Basis Event) of KALIMER-600 (Korea Advanced Liquid Metal Reactor) were analyzed in one dimension by KAERI (Korea Atomic Energy Research Institute). KALIMER-600 is the pool type SFR (Sodium cooled Fast Reactor), thereby the sodium of primary system is prohibited movement to out of a reactor vessel. There are many contacting and including compositions in the sodium hot pool, such as IHX (Intermediate Heat eXchanger), DHX (Decay Heat eXchanger), Pump, UIS (Upper Internal Structure), and core. Moreover, the complex phenomena are occurred in sodium hot pool during steady and transient states. Therefore, the one dimensional analysis is modified to the multi-dimensional analysis through modification of sodium hot pool from one to three dimensions

2010-10-01

98

Forced convective heat transfer in cross-corrugated solar air heaters  

Science.gov (United States)

Forced convective heat transfer in a cross-corrugated channel solar air heater has been studied experimentally using air as a working fluid. The channel was formed by two transversely positioned corrugated sheets and two flat thermally insulated side walls. One corrugated sheet was heated by a radiant heater, while the other was thermally insulated. The fluid velocity and temperature, and the wall temperature and the local heat flux across the heated corrugated sheet were measured for a variety of operating flow rates. Experimental results for the channel geometry have yielded the correlation Nu = 0.0743 (Re)[sup 0.76]. This heat-transfer coefficient is about 2.8 times that of a smooth flat channel. The experiments showed that local heat transfer rate was smaller on the valley of the corrugation than that on the peak. The ratio of the local heat transfer rates on the two locations was related to the Reynolds number.

1994-11-01

99

Trace element mobility in a contaminated soil two years after field-amendment with a greenwaste compost mulch  

International Nuclear Information System (INIS)

Application of greenwaste compost to brownfield land is increasingly common in soil and landscape restoration. Previous studies have demonstrated both beneficial and detrimental effects of this material on trace element mobility. A pot experiment with homogenised soil/compost investigated distribution and mobility of trace elements, two years after application of greenwaste compost mulch to shallow soils overlying a former alkali-works contaminated with Pb, Cu and As (#approx#900, 200 and 500 mg kg"-"1, respectively). Compost mulch increased organic carbon and Fe in soil pore water, which in turn increased As and Sb mobilization; this enhanced uptake by lettuce and sunflower. A very small proportion of the total soil trace element pool was in readily-exchangeable form (<0.01% As, <0.001% other trace elements), but the effect of compost on behaviour of metals was variable and ambiguous. It is concluded that greenwaste compost should be ...

2010-05-01

100

Basic models and verification study on fuel rod heat-up and fission product release analysis modules in SAMPSON for the IMPACT project  

International Nuclear Information System (INIS)

The super simulator 'SAMPSON' has been developed to show that there exist certain safety margins for light water reactors under hypothetical severe accidents and to investigate realistic measures of accident management by simulating accidents with a parallel computer. Heat-up of fuel rods and release of fission products from fuels are important factors to evaluate source terms. Models for fuel rod heat-up, hydrogen production due to cladding oxidation and cladding deformation and failure in the core region have been developed in the fuel rod heat-up analysis module. Fuel temperatures were calculated by solving the heat conduction equation. The calculated results for fuel temperature and hydrogen production were compared with CORA-13 experiment results. The comparisons showed prediction capability for the heat-up of fuel rods. The fission product release analysis module incorporates with models for fission product transport within fuel pellets, release from fuel ...

1999-04-19

101

Assessment of RELAP5 model for the University of Massachusetts Lowell research reactor  

International Nuclear Information System (INIS)

RELAP5 (Reactor Excursion and Leak Analysis Program) is a system code developed at the Idaho National Environmental and Engineering Laboratory for thermal hydraulic analysis of nuclear reactors. The code RELAP5 is widely used for safety analysis studies of commercial nuclear power plants. However, recent released version of RELAP5/3.2 and over present significant capabilities for analysis of nuclear reactor research systems. As a contribution to the assessment of RELAP5/3.3 for research reactor safety analysis, experimental data from the University of Massachusetts Lowell Research Reactor UMLRR are used. The UMLRR is a 1 MW, light water moderated and cooled, graphite-reflected, open-pool type research reactor. This paper presents the development and the validation of a UMLRR-RELAP model using experimental data. For this purpose, a series of experiments were performed for benchmarking RELAP5 calculations for research reactor systems. As a result ...

102

Analysis of the VVER-440 reactor steam generator secondary side with the RELAP5/MOD3 code  

Energy Technology Data Exchange (ETDEWEB)

Nuclear Engineering Laboratory of the Technical Research Centre of Finland has widely used RELAP5/MOD2 and -MOD3 codes to simulate horizontal steam generators. Several models have been developed and successfully used in the VVER-safety analysis. Nevertheless, the models developed have included only rather few nodes in the steam generator secondary side. The secondary side has normally been divided into about 10 to 15 nodes. Since the secondary side at the steam generators of VVER-440 type reactors consists of a rather large water pool, these models were only roughly capable to predict secondary side flows. The paper describes an attempt to use RELAP5/MOD3 code to predict secondary side flows in a steam generator of a VVER-440 reactor. A 2D/3D model has been developed using RELAP5/MOD3 codes cross-flow junctions. The model includes 90 volumes on the steam generator secondary side. The model has been used to calculate steady state flow conditions ...

1993-12-31

103

Analysis of the VVER-440 reactor steam generator secondary side with the RELAP5/MOD3 code  

International Nuclear Information System (INIS)

Nuclear Engineering Laboratory of the Technical Research Centre of Finland has widely used RELAP5/MOD2 and -MOD3 codes to simulate horizontal steam generators. Several models have been developed and successfully used in the VVER-safety analysis. Nevertheless, the models developed have included only rather few nodes in the steam generator secondary side. The secondary side has normally been divided into about 10 to 15 nodes. Since the secondary side at the steam generators of VVER-440 type reactors consists of a rather large water pool, these models were only roughly capable to predict secondary side flows. The paper describes an attempt to use RELAP5/MOD3 code to predict secondary side flows in a steam generator of a VVER-440 reactor. A 2D/3D model has been developed using RELAP5/MOD3 codes cross-flow junctions. The model includes 90 volumes on the steam generator secondary side. The model has been used to calculate steady state flow conditions ...

1992-09-29

104

An Investigation of the Relationship Between Tritium in Groundwater and the Dendrochronology of Tritium in Trees at the Savannah River Site. Final report  

Energy Technology Data Exchange (ETDEWEB)

This project was supported through ERDA to demonstrate that the temporal distribution of tritium can be documented by the analysis of bound hydrogen in annual tree-ring samples. The project focuses on two sample locations at the Savannah River Site (SRS), a nuclear material production facility located in Aiken, SC. The SRS provided samples of cross-sections from a single tree that were to be pooled together for analysis. Annual tree-rings were identified in each cross-section sample and separated for the period 1954 to 1993. These annual samples were ground and chemically treated to separate the hollocellulose fraction of the wood, then subsequently combusted and the resulting water counting using low-level liquid scintillation counting equipment. Additionally, the ground annual tree-rings were gamma-counted to determine any temporal variation in radionuclide activity and analyzed with x-ray fluorescence to find any temporal variation in ...

1995-03-21

105

Residential applliance data, assumptions and methodology for end-use forecasting with EPRI-REEPS 2.1  

Energy Technology Data Exchange (ETDEWEB)

This report details the data, assumptions and methodology for end-use forecasting of appliance energy use in the US residential sector. Our analysis uses the modeling framework provided by the Appliance Model in the Residential End-Use Energy Planning System (REEPS), which was developed by the Electric Power Research Institute. In this modeling framework, appliances include essentially all residential end-uses other than space conditioning end-uses. We have defined a distinct appliance model for each end-use based on a common modeling framework provided in the REEPS software. This report details our development of the following appliance models: refrigerator, freezer, dryer, water heater, clothes washer, dishwasher, lighting, cooking and miscellaneous. Taken together, appliances account for approximately 70% of electricity consumption and 30% of natural gas consumption in the US residential sector. Appliances are thus important to those ...

1994-05-01

106

Method for controlling the liquid level of a steam generator for a sodium-cooled fast breeder reactor  

International Nuclear Information System (INIS)

Object: To control the average liquid level of each steam generator at a constant level irrespective of the flow rate of sodium thereby to decrease change in the retained amount of sodium and at the same time to improve the load response characteristic. Construction: A method for decreasing to as large an extent as possible a change in the amount of sodium retained in a steam generator due to change in the flow rate, which comprises the steps of detecting the main recirculating flow rate of liquid sodium by the use of a sodium flow rate detector, amplifying the detected flow rate signal depending upon the ratio between the flow rates respectively in a super-heater and a re-heater (distribution ratio), delivering the amplified signal to a function generator which generates a liquid level setting signal for maintaining the respective average liquid levels of the super-heater and the re-heater at constant ...

107

Failure analysis of CO_2 anti-freezing heater at Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

In this paper, an investigation was performed on a failure pressure vessel, which was as an anti-freezing heater for General Gas Storage and Distribution (SGZ) system. Evident and serious deformation was observed on the body of the vessel. A metallurgical investigation was conducted to establish the mechanism and cause of deformation of the anti-freezing heater at Daya Bay PWR station in China. The investigation, which was performed on specimens cut from the most serious area deformed of the vessel, included macroscopic examination and microscopy examination. The results of the examinations showed that some lamellar pearlite in the microstructure were already spheroidized. It was confirmed that the vessel was operated at high temperature. Stress analysis for the vessel was conducted. And it was confirmed that, in ideal conditions, the vessel would be deformed at around 420 C. The overall results of the investigation showed that the failure of ...

2002-09-23

108

Earthbeat - 25/5/2002: Woodsmoke, Health & the Environment  

Wastenet

...wood smoke, emissions, pollution, heaters, environment, Earthbeat - 25/5/2002: Woodsmoke, Health & the Environment Love that Planet All in the Mind The Buzz Health Report In Conversation Ockhams Razor Science Show The Lab Health Matters Catalyst Quantum ...

109

Effects of vaporizer and evaporative-condenser size on geofluid effectiveness and cost of electricity for geothermal binary power plants  

Energy Technology Data Exchange (ETDEWEB)

A special study was conducted to investigate the influences of minimum approach temperature differences occurring in supercritical-heater/vaporizer and evaporative-condenser heat rejection systems on geothermal-electric binary power plant performance and cost of electricity. For the systems investigated optimum pinch points for minimizing cost of electricity were estimated to range from 5 to 7/sup 0/F for the heater vaporizer. The minimum approach of condensing temperature to wet-bulb temperature for evaporative condensers was estimated to be about 30/sup 0/F in order to achieve the lowest cost of electricity.

1983-10-01

110

A new procedure for cutting out the broken thermocouple tubes inside the deep holes in the tube plate of moisture re-heater at Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

The scenario of the development of a new procedure for cutting out the broken protective wells for thermocouples inside the deep holes in the tube plate in the moisture re-heater (MSR) at Daya Bay nuclear power station is presented. Focused in the innovation and improvement of the self-made tools, the new procedure produced an effective method to cut out swing long inserts stuck inside the deep holes. (authors)

2005-09-01

111

ESBWR related passive decay heat removal tests in PANDA  

International Nuclear Information System (INIS)

A number of test series to investigate passive safety systems for the next generation of Light Water Reactors have been performed in the PANDA multi-purpose facility at the Paul Scherrer Institut (PSI). The large scale thermal-hydraulic test facility allows to investigate LWR containment phenomena and system behaviour. PANDA was first used to examine the Passive Containment Cooling System (PCCS) for the Simplified Boiling Water Reactor (SBWR). In 1996 new test series were initiated; all related to projects of the EC Fourth Framework Programme on Nuclear Fission Safety. One of these projects (TEPSS) is focused on the European Simplified Boiling Water Reactor (ESBWR). The ESBWR containment features and PCCS long-term post LOCA response were investigated in PANDA. The PCCS start-up was demonstrated, the effect of nitrogen hidden somewhere in the drywell and released later in the transient was simulated and the effect of light ...

1999-04-19

112

On the optimal taxation of common-pool resources  

British Library Electronic Table of Contents (United Kingdom)

Recent research developments in common-pool resource models emphasize the importance of links with ecological systems and the presence of non-linearities, thresholds and multiple steady states. In a recent paper Kossioris et al. (2008) develop a methodology for deriving feedback Nash equilibria for non-linear differential games and apply this methodology to a common-pool resource model of a lake where pollution corresponds to benefits and at the same time affects the ecosystem services. This paper studies the structure of optimal state-dependent taxes that steer the combined economic-ecological system towards the trajectory of optimal management, and provides an algorithm for calculating such taxes.

2011-01-01

113

Effects of carbocalcitonin treatment on PAGET's disease assessed by quantitative bone scintigraphy  

International Nuclear Information System (INIS)

Sixteen patients with PAGET's disease of bone underwent quantitative bone scintigraphy with "9"9"mTc-MDP before and after a long-term treatment with carbocalcitonin, a synthetic analogue of eel calcitonin. The radionuclide study consisted in the blood pool and bone uptake measurement and in the bone avidity calculation (bone uptake - blood pool ratio). In our patients, a significant decrease in bone uptake and bone avidity was found, whereas the blood pool remained statistically unchanged. This behaviour could be accounted for the shift of the compact bone to a lamellar pattern. (orig.).

114

Effects of carbocalcitonin treatment on PAGET's disease assessed by quantitative bone scintigraphy  

Energy Technology Data Exchange (ETDEWEB)

Sixteen patients with PAGET's disease of bone underwent quantitative bone scintigraphy with /sup 99m/Tc-MDP before and after a long-term treatment with carbocalcitonin, a synthetic analogue of eel calcitonin. The radionuclide study consisted in the blood pool and bone uptake measurement and in the bone avidity calculation (bone uptake - blood pool ratio). In our patients, a significant decrease in bone uptake and bone avidity was found, whereas the blood pool remained statistically unchanged. This behaviour could be accounted for the shift of the compact bone to a lamellar pattern.

1988-06-01

115

Decontamination factors and release rates of UO/sub 2/ particles from boiling pools of sodium  

Energy Technology Data Exchange (ETDEWEB)

A semi-mechanistic model for calculating solid radionuclide release rates from bubbling pools of sodium was developed. The influence of particle spacial and size distributions on the decontamination of the releases was analysed and found significant. Decontamination factors are shown as a function of pool depth, bubbling characteristics and particle size distribution. The calculation of a decontamination factor for estimating the source term of large scale hypothetical core disruptive accidents is presented. The decontamination factor for a large scale accident was found to be two orders of magnitude greater than results obtained from small scale experiments conducted with uniform particle distributions.

1983-01-01

116

Decontamination factors and release rates of UO"2 particles from boiling pools of sodium  

International Nuclear Information System (INIS)

A semi-mechanistic model for calculating solid radionuclide release rates from bubbling pools of sodium was developed. The influence of particle spacial and size distributions on the decontamination of the releases was analysed and found significant. Decontamination factors are shown as a function of pool depth, bubbling characteristics and particle size distribution. The calculation of a decontamination factor for estimating the source term of large scale hypothetical core disruptive accidents is presented. The decontamination factor for a large scale accident was found to be two orders of magnitude greater than results obtained from small scale experiments conducted with uniform particle distributions. (orig.).

117

Of Microenvironments and Mammary Stem Cells  

UK PubMed Central (United Kingdom)

In most adult tissues there reside pools of stem and progenitor cells inside specialized microenvironments referred to as niches. The niche protects the stem cells from inappropriate expansion...Full Text Available

2007-06-01

118

NEX - Analysis of ENSO Dynamics and ThermoDynamics in the ... - NASA  

Science.gov (United States)

Analysis of ENSO Dynamics and ThermoDynamics in the Western Pacific Warm Pool - An Application of Multi-Sensor Satellite Observations. ...

119

NASA - Students' Robots to Take Place of Spacewalkers in NASA Pool  

Science.gov (United States)

Jun 21, 2006 ... The competition is organized by the Marine Advanced Technology Education Center (MATE) and Marine Technology Society's (MTS) ROV Committee. ...

120

Analysis of nifH Gene Pool Complexity in Soil and Litter at a Douglas Fir Forest Site in the Oregon Cascade Mountain Range  

UK PubMed Central (United Kingdom)

Nitrogen-fixing microbial populations in a Douglas fir forest on the western slope of the Oregon Cascade Mountain Range were analyzed. The complexity of the nifH gene pool (nifH...Full Text Available

1999-02-01

121

A study on natural convection heat transfer with crust formation in the corium pool  

International Nuclear Information System (INIS)

Experimental and analytical studies in convection cooling and boiling cooling conditions have been performed on natural convection heat transfer with solidified crust formation in the molten metal pool. The present experimental results on the relationship between the Nusselt number and Rayleigh number in the molten metal pool were compared with existing correlations on Rayleigh-Bebard natural convection in an enclosure. A new correlation on the relationship between the Nusselt number and Rayleigh number in the molten metal pool with crust formation has been developed using the experimental data. The experimental results were verified by the analytical study. The experimental study has shown that the bottom surface temperature of the molten metal layer, in all experiments, is the major influential parameter in the crust formation, due to the natural convection flow. The Nusselt number of the case without a crust formation in ...

122

Method and apparatus for spraying molten materials  

Energy Technology Data Exchange (ETDEWEB)

A metal spray apparatus is provided with a supersonic nozzle. Molten metal is injected into a gas stream flowing through the nozzle under pressure. By varying the pressure of the injected metal, the droplet can be made in various selected sizes with each selected size having a high degree of size uniformity. A unique one piece graphite heater provides easily controlled uniformity of temperature in the nozzle and an attached tundish which holds the pressurized molten metal. A unique U-shaped gas heater provides extremely hot inlet gas temperatures to the nozzle. A particularly useful application of the spray apparatus is coating of threads of a fastener with a shape memory alloy. This permits a fastener to be easily inserted and removed but provides for a secure locking of the fastener in high temperature environments.

1996-01-01

123

Development of a greenhouse-type solar dryer for medicinal plants and herbs  

Energy Technology Data Exchange (ETDEWEB)

The economy of medicinal plant production is burdened considerably by the energy costs of drying. To substitute fossil energy, a solar heated dryer was developed, taking a plastic film greenhouse as superstructure to lower the initial costs. The solar air heaters, being incorporated into the roof, consist of a black absorber tissue, which is placed between the transparent cover of the greenhouse and an insulating air-bubble foil. To obtain a modular design, the system is structured along the ridge into segments of 2 m width. Each segment forms an independent solar air heater/batch dryer unit and is operated by a fan with a power consumption of 500 W. A prototype was tested in Yugoslavia, drying mint, sage and hops. (author).

1989-01-01

124

Design and operation of an apparatus for calorimetric emittance measurements of pipe surfaces  

Energy Technology Data Exchange (ETDEWEB)

A technique for the measurement of the total hemispherical emittance of pipe surfaces is described, and design and operational details are given. The technique is conceptually simple. A long test pipe (e.g., 3.4 m) is mounted concentrically inside a Pyrex glass pipe. The system is evacuated, and the test pipe is heated by means of an electrical resistance heater. Heat transfer from the test pipe to the enclosure is almost solely radiative, allowing an average emittance for the test pipe and the Pyrex pipe and the electrical power input to the heater. By varying the electrical power level, one can measure the test pipe emittance as a function of temperature. By using a simple correction to account for the finite length of the test pipe, one can calculate the results using the simple expression for infinite, concentric cylinders. Results agree with measurements by reflectance techniques and have a nominal relative error of less than 10%.

1981-10-01

125

Aespoe Pillar Stability Experiment. Acoustic emission and ultrasonic monitoring  

Energy Technology Data Exchange (ETDEWEB)

This report describes the results from acoustic emission (AE) and ultrasonic monitoring of the Aespoe Pillar Stability Experiment (APSE) at SKB's Hard Rock Laboratory (HRL), Sweden. The APSE is being undertaken to demonstrate the current capability to predict spalling in a fractured rock mass using numerical modelling techniques, and to demonstrate the effect of backfill and confining pressure on the propagation of micro-cracks in rock adjacent to deposition holes within a repository. An ultrasonic acquisition system has provided acoustic emission and ultrasonic survey monitoring throughout the various phases of the experiment. Results from the entire data set are provided with this document so that they can be effectively compared to several numerical modelling studies, and to mechanical and thermal measurements conducted around the pillar volume, in an 'integrated analysis' performed by SKB staff. This document provides an in-depth summary of the AE and ...

2005-12-15

126

TRIGA spent fuel bundles safe storage  

International Nuclear Information System (INIS)

TRIGA-SSR is a steady state research and material test reactor that has been in operation since 1980. The original TRIGA fuel was HEU (highly enriched uranium) with a U"2"3"5 enrichment of 93 per cent. Almost all TRIGA HEU fuel bundles are now burned-up. Part of the spent fuel was loaded and transferred to US, in a Romania - DOE arrangement. The rest of the TRIGA fuel bundles have to be temporarily stored in the TRIGA facility. As the storage conditions had to be established with caution, neutron and thermal hydraulic evaluations of the storage conditions were required. Some criticality evaluations were made based on the SAR (Safety Analysis Report) data. Fuel constant axial temperature approximation effect is usual for criticality computations. TRIGA-SSR fuel bundle geometry and materials model for SCALE5-CSAS module allows the introduction of a fuel temperature dependency for the entire fuel active height, using different materials for each fuel bundle region. Previous RELAP5 thermal ...

2007-05-13

127

Spent Fuel Background Report Volume I  

Energy Technology Data Exchange (ETDEWEB)

This report is an overview of current spent nuclear fuel management in the DOE complex. Sources of information include published literature, internal DOE documents, interviews with site personnel, and information provided by individual sites. Much of the specific information on facilities and fuels was provided by the DOE sites in response to the questionnaire for data for spent fuels and facilities data bases. This information is as accurate as is currently available, but is subject to revision pending results of further data calls. Spent fuel is broadly classified into three categories: (a) production fuels, (b) special fuels, and (c) naval fuels. Production fuels, comprising about 80% of the total inventory, are those used at Hanford and Savannah River to produce nuclear materials for defense. Special fuels are those used in a wide variety of research, development, and testing activities. Special fuels include fuel from DOE and commercial reactors used in research activities at DOE ...

1994-03-01

128

Nitrogen metabolism and protozoa production rate in cattle fed on diet containing protected protein  

International Nuclear Information System (INIS)

Nitrogen metabolism and protozoa production rate using "1"4C-choline as marker were studied on 9 adult male crossbred (Tharparker x Brown Swiss) rumen fistulated animals divided into 3 groups (A, B and C). All the animals were fed concentrate mixture and wheatstraw. However, groundnut cake (GNC) in concentrate mixture was untreated in group A, 50 per cent formaldehyde treated in group B and 100 per cent formaldehyde treated in group C. Although, DM intake was similar in these groups but water intake was significantly (P<0.05) higher in control group. Total-N, ammonia-N and blood urea were significantly lower in group B and C as compared to group A. Apparent CP digestibility was not affected by addition of formaldehyde treated GNC at 50 and 100 per cent levels. However, N balances increased significantly (P<0.05) due to addition of protected protein in diet. Protozoal pool as well as production rate were significantly (P<0.01) decreased ...

129

Natural and anthropogenic "1"4C in the UK coastal marine environment  

International Nuclear Information System (INIS)

Prior to this study, almost no up-to-date information was available on the 'background' level of "1"4C present in the water and biota of the UK coastal marine environment. The weighted mean "1"4C activity derived from the lowest activities of dissolved inorganic carbon (DIC) and biota for sites which are remote from potential sources is 247#centre dot#6#+-#1#centre dot#0 Bq kg"-"1 carbon. This is proposed as the best estimate of the natural/weapons testing 'background' for 1995 and should be subtracted from the activity derived for any sample to establish the excess due to UK anthropogenic inputs. "1"4C activities in the DIC component of seawater and a range of marine biota are significantly enhanced above the expected 'background' value in the environment around the British Nuclear Fuels plc reprocessing plant at Sellafield, Cumbria, NW England and Amersham International plc, Cardiff, Wales. The enrichments around Sellafield are largely confined to the NE Irish ...

1997-07-01

130

Feasibility of fissile mass assay of spent nuclear fuel using {sup 252}Cf-source-driven frequency-analysis  

Energy Technology Data Exchange (ETDEWEB)

The feasibility was evaluated using MCNP-DSP, an analog Monte Carlo transport cod to simulate source-driven measurements. Models of an isolated Westinghouse 17x17 PWR fuel assembly in a 1500-ppM borated water storage pool were used. In the models, the fuel burnup profile was represented using seven axial burnup zones, each with isotopics estimated by the PDQ code. Four different fuel assemblies with average burnups from fresh to 32 GWd/MTU were modeled and analyzed. Analysis of the fuel assemblies was simulated by inducing fission in the fuel using a {sup 252}Cf source adjacent to the assembly and correlating source fissions with the response of a bank of {sup 3}He detectors adjacent to the assembly opposite the source. This analysis was performed at 7 different axial positions on each of the 4 assemblies, and the source-detector cross-spectrum signature was calculated for each of these 28 simulated measurements. The magnitude of the ...

1996-10-01

131

Market-based pricing and demand-side participation in the electricity pool of England and Wales  

Energy Technology Data Exchange (ETDEWEB)

This paper focuses upon the workings of the electricity pool of England and Wales. Created as a generators` pool, with the twin objectives of preserving order-of-merit dispatch and setting marginal-cost pricing signals, it is now evident that the system may not provide an efficient market-clearing mechanism from the consumers` perspective. Thus, over the five years since its inception, there have been repeated calls to incorporate more explicitly demand-side pricing signals into the process. A number of official reviews and various consultants have looked at the issue and there have been trial periods of active demand-side bidding. This paper reviews that experience to date.

1996-03-01

132

Simulation of thermal behavior of nuclear fuel rod by electrically heated pin  

International Nuclear Information System (INIS)

The utilization of electrically heated rods for the simulation of nuclear fuel rods represents an universally adopted method by the nuclear industry to study thermalhydraulic problems. The present work represents the development of a method to obtain the time variation of the electric linear power necessary to simulate a given nuclear power transient in order to yield the same temperature and heat flux conditions in the surface of the electrical heater that would be obtained by the nuclear fuel rod. (Author).

1985-12-10

133

Radiative Heat Transfer Augmentation in High Temperature Combustion Systems with Application to Radiant Tube Burners. Final Report, April 1987-March 1990.  

Science.gov (United States)

Gas fired radiant tube heaters provide an indirect heating source for applications in which direct contact cannot be permitted between combustion gases and the workpiece. The program was an investigation of ways to improve performance of such burners thro...

1990-01-01

134

Oil/electric hybrid heating experiment and demonstration. [Executive summary is a separate volume  

Energy Technology Data Exchange (ETDEWEB)

Oil/electric heating systems and energy measuring instrumentation were installed in 50 houses in Deep River, Ontario. These were operated and monitored for two heating seasons to demonstrate their performance and determine the percentage oil placement as a function of heater capacity and control system. All experimental data was stored and processed by computer. It was found that oil furnace utilization efficiency varied from 48 to 59% for an average of 53.5%. Oil displacement ranged from 49 to 83% for 2.5 and 5.0 kW electric heaters controlled by two-stage indoor thermostats. Fuel costs for oil/electric hybrid heating, with 5.0 kW plenum heaters and indoor two-stage thermostats, were 20% less than for oil heating, based on average furnace efficency and 1983 January retail fuel prices. Annual load factors above 37% were achieved for plenum heaters compared to 11.9% for all-electric systems. Space ...

1983-07-01

135

Final Report: Optimization of Chemical Process Heater and Combustion Systems, September 1, 1996 - August 31, 1999  

Energy Technology Data Exchange (ETDEWEB)

The optimization of ethylene furnace operations using cfd-based simulations has been addressed. The optimization problems have been cast into various formulations: the Multidisciplinary feasible (MDF) approach, the All-At-Once (AAO) approach and the Individual discipline feasible (IDF) approach. These approaches mainly differ in their handling of the state equations as constraints, and hence some of the formulations place restrictions on the methods used to solve the state equations.

1999-08-31

136

Wild-derived mouse stocks: an underappreciated tool for aging research  

UK PubMed Central (United Kingdom)

Virtually all biomedical research makes use of a relatively small pool of laboratory-adapted, inbred, isogenic stocks of mice. Although the advantages of these models are many, there are a number of...Full Text Available

2008-09-01

137

Uracil-DNA glycosylase: Structural, thermodynamic and kinetic aspects of lesion search and recognition  

UK PubMed Central (United Kingdom)

Uracil appears in DNA as a result of cytosine deamination and by incorporation from the dUTP pool. As potentially mutagenic and deleterious for cell regulation, uracil must be removed from DNA....Full Text Available

2010-03-01

138

The use of nitrogen isotopes in research on sheep nutrition  

International Nuclear Information System (INIS)

Using nitrogen-13 initial measurements have been made of rumen ammonia-nitrogen pool size and turnover, and rate of incorporation of ammonia into microbial protein. It is also feasible to measure the rate of incorporation of absorbed ammonia into urea and the appearance of label in saliva.

1985-08-26

139

The Differing Impact of Multisensory and Unisensory Integration on Behavior  

UK PubMed Central (United Kingdom)

Pooling and synthesizing signals across different senses often enhances responses to the event from which they are derived. Here we examine whether multisensory response enhancements are attributable...Full Text Available

2009-04-15

140

Stability of prothrombin and factor VII in freeze-dried plasma  

UK PubMed Central (United Kingdom)

The stability of prothrombin and factor VII was studied using accelerated degradation tests in three preparations of freeze-dried pooled normal plasmas. In a previous report (Brozović, Gurd,...Full Text Available

1971-11-01

141

Some New Aspects of the in Vivo Assay for Nitrate Reductase in Wheat (Triticum aestivum L.) Leaves  

UK PubMed Central (United Kingdom)

Experiments were carried out to clarify problems encountered in measuring metabolic and storage pool sizes of nitrate in wheat leaf sections with an in vivo nitrate reductase assay....Full Text Available

1980-01-01

142

Risk of Colon Cancer and Coffee, Tea, and Sugar-Sweetened Soft Drink Intake: Pooled Analysis of Prospective Cohort Studies  

British Library Electronic Table of Contents (United Kingdom)

Background The relationships between coffee, tea, and sugar-sweetened carbonated soft drink consumption and colon cancer risk remain unresolved. Methods We investigated prospectively the association between coffee, tea, and sugar-sweetened carbonated soft drink consumption and colon cancer risk in a pooled analysis of primary data from 13 cohort studies. Among 731 441 participants followed for up to 6-20 years, 5604 incident colon cancer case patients were identified. Study-specific relative risks (RRs) and 95% confidence intervals (CIs) were estimated using Cox proportional hazards models and then pooled using a random-effects model. All statistical tests were two-sided. Results Compared with nonconsumers, the pooled multivariable relative risks were 1.07 (95% CI = 0.89 to 1.30, Ptrend = ...

2010-01-01

143

Phylogeny of Mitochondrial DNA Macrohaplogroup N in India, Based on Complete Sequencing: Implications for the Peopling of South Asia  

UK PubMed Central (United Kingdom)

To resolve the phylogeny of the autochthonous mitochondrial DNA (mtDNA) haplogroups of India and determine the relationship between the Indian and western Eurasian mtDNA pools more precisely, a diverse...Full Text Available

2004-12-01

144

New strain of mouse hepatitis virus as the cause of lethal enteritis in infant mice.  

UK PubMed Central (United Kingdom)

A new strain of mouse hepatitis virus (MHV) was isolated from pooled gut suspensions from an epizootic of lethal enteritis in newborn mice. Negative-contrast electron microscopy showed an abundance...Full Text Available

1979-05-01

145

Intravenous immunoglobulin in the treatment of primary trigeminal neuralgia refractory to carbamazepine: a study protocol[ISRCTN33042138  

UK PubMed Central (United Kingdom)

BackgroundWe have recently reported successful treatment of patients with chronic pain syndromes using human pooled intravenous immunoglobulin (IVIG) in a prospective, open-label...Full Text Available

146

Functional pools of oxidative and glycolytic fibers in human muscle observed by 31P magnetic resonance spectroscopy during exercise.  

UK PubMed Central (United Kingdom)

Quantitative probing of heterogeneous regions in muscle is feasible with phosphorus-31 magnetic resonance spectroscopy because of the differentiation of metabolic patterns of glycolytic and oxidative...Full Text Available

1987-12-01

147

Efficient discovery of ASCL1 regulatory sequences through transgene pooling  

UK PubMed Central (United Kingdom)

Zebrafish transgenesis is a powerful and increasingly common strategy to assay vertebrate transcriptional regulatory control. Several challenges remain, however, to the broader application of...Full Text Available

2010-06-01

148

Effect of pH and osmolality on in vitro phagocytosis and killing by neutrophils in urine.  

UK PubMed Central (United Kingdom)

Phagocytosis and intracellular killing of two strains of Escherichia coli and a Staphylococcus saprophyticus by polymorphonuclear neutrophils (PMN) in pooled sterile urine at three osmolalities (800,...Full Text Available

1993-01-01

149

Design of 240,000 orthogonal 25mer DNA barcode probes  

UK PubMed Central (United Kingdom)

DNA barcodes linked to genetic features greatly facilitate screening these features in pooled formats using microarray hybridization, and new tools are needed to design large sets of barcodes to allow...Full Text Available

2009-02-17

150

Body Mass Index and Diabetes in Asia: A Cross-Sectional Pooled Analysis of 900,000 Individuals in the Asia Cohort Consortium  

UK PubMed Central (United Kingdom)

BackgroundThe occurrence of diabetes has greatly increased in low- and middle-income countries, particularly in Asia, as has the prevalence of overweight and obesity; in European-derived...Full Text Available

151

An oncogenomics-based in vivo RNAi screen identifies tumor suppressors in liver cancer  

UK PubMed Central (United Kingdom)

Cancers are highly heterogeneous and contain many passenger and driver mutations. To functionally identify tumor suppressor genes relevant to human cancer, we compiled pools of short harpin...Full Text Available

2008-11-28

152

Active release of human platelet factor VIII-related antigen by adenosine diphosphate, collagen, and thrombin.  

UK PubMed Central (United Kingdom)

Platelet Factor VIII-related antigen (VIIIR:Ag) represents a significant proportion of the total circulating VIIIR:Ag pool. However, its participation in the events of primary hemostasis has not been...Full Text Available

1978-12-01

153

Carbon tetrachloride-induced release of calcium from isolated hepatocytes  

International Nuclear Information System (INIS)

Studies have shown that CCl_4 administration to rats inhibits endoplasmic reticulum calcium pump activity and reduces the amount of calcium associated with subsequently isolated microsomal subcellular fractions. This report confirms that exposure of isolated hepatocytes to CCl_4 rapidly produces these effects in isolated parenchymal cells and demonstrates that when isolated hepacytes are exposed to CCl_4 calcium is rapidly released from cells. This release can be detected with a calcium ion-selective electrode when cells are incubated in a medium with low extracellular calcium. Calcium released from an intracellular pool(s) may initiate hepatotoxic changes in liver. (author).

154

A Cautionary Tale: Small Sample Size Concerns for Grouped Lifetime Data  

British Library Electronic Table of Contents (United Kingdom)

Often, lifetime data come from experiments where failure times are grouped. The Weibull distribution is a popular distribution for modeling failure times. Maximum likelihood estimation (MLE) has outstanding large sample properties for the Weibull distribution. This article evaluates small sample properties of MLEs for grouped data. We evaluate sample size requirements for MLE asymptotic properties to take effect. We compare type I and type II censoring for pooled experiments and conclude that bias for the shape parameter estimate can be alarmingly high especially for type II censored data. Finally, we investigate the benefits of the pooled analysis.

2011-01-01

155

NOx Sensor Development  

Energy Technology Data Exchange (ETDEWEB)

NO{sub x} compounds, specifically NO and NO{sub 2}, are pollutants and potent greenhouse gases. Compact and inexpensive NO{sub x} sensors are necessary in the next generation of diesel (CIDI) automobiles to meet government emission requirements and enable the more rapid introduction of more efficient, higher fuel economy CIDI vehicles. Because the need for a NO{sub x} sensor is recent and the performance requirements are extremely challenging, most are still in the development phase. Currently, there is only one type of NO{sub x} sensor that is sold commercially, and it seems unlikely to meet more stringent future emission requirements. Automotive exhaust sensor development has focused on solid-state electrochemical technology, which has proven to be robust for in-situ operation in harsh, high-temperature environments (e.g., the oxygen stoichiometric sensor). Solid-state sensors typically rely on yttria-stabilized zirconia (YSZ) as the oxygen-ion conducting electrolyte and then target ...

2010-11-01

156

FDS3 simulations of indoor hydrocarbon fires engulfing radioactive waste packages  

International Nuclear Information System (INIS)

The thermal environment of a hypothetical large indoor hydrocarbon pool fire is more complex compared to outdoor fires and can be more severe for engulfed objects. In order to analyze potential thermal environments for interim storage of spent fuel casks or low-level radioactive waste packages engulfed in pool fires numerical simulations with the CFD fire code FDS3 were carried out for different storage configurations. In addition, data of indoor pool fire experiments were used to validate the model for this type of application. A series of pool fire experiments under different ventilation conditions and varied pool surface (1 m"2 - 4 m"2) inside a compartment of 3.6 m x 3.6 m x 5.7 m was conducted at iBMB (Institut fuer Baustoffe, Massivbau und Brandschutz) of Braunschweig University of Technology, Germany. The instrumentation included thermocouples, heatflux and pressure gauges, ...

2004-09-20

157

Water Quality and 401 Certification | Clean Water Act | US EPA  

Science.gov (United States)

Clean Water Act You are here: Water Laws & Regulations Policy & Guidance Clean Water Act Water Quality and 401 Certification Water Quality and 401 Certification Water Quality...

2011-08-28

158

Development of a high performance air heater through use of an evacuated tube cover design  

Science.gov (United States)

Development of a high performance air heater through use of an evacuated tube cover design is described. The cover design utilizes evacuated fluorescent light tubes laid parallel in a close packed array to form an inner transparent glazing over a conventional metal absorber plate with flow behind the plate. A tempered flat glass plate was used as an outer glazing. Both clear and infrared reflective (IR) tubes were investigated. Solar transmittance tests indicate that the clear tube array has a higher transmittance than two flat sheets of low-iron glass. The IR coating produced substantial transmittance loss. Thermal conductance tests indicate that the tubes behave similar to two flat glass sheets with a vacuum in between. The IR reflective coating was only marginally effective at reducing heat conductance. Final prototype designs are presented along with collector performance estimates.

1980-01-01

159

Solar power station. Sonnenkraftwerk  

Energy Technology Data Exchange (ETDEWEB)

The invention concerns a solar power station with a hollow solar heater, which has reflected radiation coming in, focussed by a mirror through the inlet opening. To match the differing solar radiation during the day, the inlet opening can be adjusted by changing its cross-section. This is done by at least two thick flat circular parts which can move relative to each other which are preferably movable relative to each other in pairs on a common rail and which are cooled by a coolant which is the working medium for absorbing solar energy.

1982-02-25

160

Design parameters for tube cavity receivers in solar power plants  

Energy Technology Data Exchange (ETDEWEB)

The design of a solar heated cavity receiver transferring 60 MW of thermal energy to the working medium (air) for a closed-cycle gas turbine is described. The gas turbine plant with its cycle layout is presented. Then the tubes for the receiver are designed taking into account thermal and mechanical loads. It is shown how the occurring stresses are influenced by the destribution of the locally absorbed hat flux. Calculations for an existing coal fired air heater of a closed-cycle gas turbine give a first impression of the long-term behaviour to be expected of the receiver tubes.

1981-01-01

161

Boiling transition under thermal hydraulic instability in rod bundle  

International Nuclear Information System (INIS)

Experiments have been performed on the electrically heated rod bundles to investigate the characteristics of the boiling transition under flow oscillation (OSBT) during thermal hydraulic instability. After determining the instability threshold power (Q/sub OS/), the electrical power to the test section was increased further up to the threshold power (Q/sub OSBT/) at which it was detected by the thermocouples that the boiling transition (BT) occurred and the heater rod temperature reached 613 K. Experimental results show that Q/sub OSBT/ is larger than Q/sub OS/ by a certain margin, which depends on the test conditions.

162

The importance of sodium plume behaviour in the natural convection cooling of fast reactors  

International Nuclear Information System (INIS)

This paper relates to a simple approach to the analysis of the behaviour of pool type LMFBR primary circuits in natural convection and to experimental work to support this approach. The primary application is the prediction of plant behaviour in decay heat removal conditions when depending on natural convection effects to cool the core. In formulating a mathematical model of the plant for this application, the main difficulty is the modelling of the large plena between the core and IHX and the IHX and the pump inlet. In a previous paper discussing CDFR behaviour after a reactor scram with total loss of power to the primary pumps, the first author described attempts to model the CDFR hot pool in a way which would be limiting in a pessimistic sense. The shortcomings of these attempts were reviewed and mention was made of an improved method then under development. Essentially, the improved model allowed for migration of hot sodium from the core to ...

163

Users' guide on socket heat fusion joining of polyethylene gas pipes. Volume 1. Topical report, September 1989-September 1990  

Energy Technology Data Exchange (ETDEWEB)

The integrity of a pipeline system is determined by its weakest links which may be the joints. Heat fusion is the most common method for joining gas distribution polyethylene (PE) piping. There are procedural, thermal, and mechanical aspects of making fusion joints. Acceptable procedural aspects, such as heater calibration and cleanliness, can be assured by rigorous training and certification of the operators. Thermal and mechanical aspects consist of specifying joining conditions such as the heater temperature, heating time, and joining pressure. In the absence of procedural errors, the strength of a fusion joint should depend on the pipe material, pipe dimensions, and the thermal and mechanical joining conditions. Socket heat fusion was studied both experimentally and analytically to determine how the strength of the joint varied with the conditions under which it was made. The standard tensile impact test was modified to test socket fusion ...

1991-03-01

164

Technical reference on socket heat fusion joining of polyethylene gas pipes. Volume 2. Topical Report, September 1989-September 1990  

Energy Technology Data Exchange (ETDEWEB)

The integrity of a pipeline system is determined by its weakest links which may be the joints. Heat fusion is the most common method for joining gas distribution polyethylene (PE) piping. There are procedural, thermal, and mechanical aspects of making fusion joints. Acceptable procedural aspects, such as heater calibration and cleanliness, can be assured by rigorous training and certification of the operators. Thermal and mechanical aspects consist of specifying joining conditions such as the heater temperature, heating time, and joining pressure. In the absence of procedural errors, the strength of a fusion joint should depend on the pipe material, pipe dimensions, and the thermal and mechanical joining conditions. Socket heat fusion was studied both experimentally and analytically to determine how the strength of the joint varied with the conditions under which it was made. The standard tensile impact test was modified to test socket fusion ...

1991-03-01

165

Externally-fired combined cycle: An effective coal fueled technology for repowering and new generation  

Energy Technology Data Exchange (ETDEWEB)

The Externally-Fired Combined Cycle (EFCC) is an attractive emerging technology for powering high efficiency combined gas and steam turbine cycles with coal or other ash bearing fuels. In the EFCC, the heat input to a gas turbine is supplied indirectly through a ceramic air heater. The air heater, along with an atmospheric coal combustor and ancillary equipment, replaces the conventional gas turbine combustor. A steam generator located downstream from the ceramic air heater and steam turbine cycle, along with an exhaust cleanup system, completes the combined cycle. A key element of the EFCC Development Program, the 25 MMBtu/h heat-input Kennebunk Test Facility (KTF), has recently begun operation. The KTF has been operating with natural gas and will begin operating with coal in early 1995. The US Department of Energy selected an EFCC repowering of the Pennsylvania Electric Company`s Warren Station for funding under the Clean ...

1995-06-01

166

Development of fire simulation models for radiative heat transfer and probabilistic risk assessment  

Energy Technology Data Exchange (ETDEWEB)

An essential part of fire risk assessment is the analysis of fire hazards and fire propagation. In this work, models and tools for two different aspects of numerical fire simulation have been developed. The primary objectives have been firstly to investigate the possibility of exploiting state-of-the-art fire models within probabilistic fire risk assessments and secondly to develop a computationally efficient solver of thermal radiation for the Fire Dynamics Simulator (FDS) code. In the first part of the work, an engineering tool for probabilistic fire risk assessment has been developed. The tool can be used to perform Monte Carlo simulations of fires and is called the Probabilistic Fire Simulator (PFS). In Monte Carlo simulation, the simulations are repeated multiple times, covering the whole range of variability of the input parameters and thus resulting in a distribution of results covering what can be expected in reality. In practical applications, advanced simulation techniques ...

2008-07-01

167

Snow Survey & Water Supply | NRCS  

Science.gov (United States)

Programs & Services Technical Resources Land Use Soils Water Snow Survey & Water Supply Water Management Water Quality Watersheds Wetlands Air Plants & Animals Energy Climate...

2011-08-21

168

A study on the management of spent fuel storage capacity in South Korea  

International Nuclear Information System (INIS)

The saturation of South Korea's at-reactor (AR) spent fuel storage pools will create a necessity for additional spent fuel storage capacity. Because the South Korean government has the plan to increase the number of nuclear power plants from 20 units (end of 2005) to 27 units by 2015, the increase of spent nuclear fuel generation will be accelerated. Because there is no clear national plan for spent nuclear fuel storage and disposal, the utility company (Korea Hydraulic Nuclear Power company) is planning to construct a spent fuel storage facility with 11 000 tHM capacity for Pressurised Water Reactor (PWR). This study is intended to predict the maximum allowable periods when the storage facility will be fully occupied with respect to the already fixed re-racking plan of spent fuel storage pools and construction of new nuclear power plants. The result from this study will be used as fundamental data for an efficient ...

2006-06-19

169

Radiation inactivation target size of rat adipocyte glucose transporters in the plasma membrane and intracellular pools  

Energy Technology Data Exchange (ETDEWEB)

The in situ assembly states of the glucose transport carrier protein in the plasma membrane and in the intracellular (microsomal) storage pool of rat adipocytes were assessed by studying radiation-induced inactivation of the D-glucose-sensitive cytochalasin B binding activities. High energy radiation inactivated the glucose-sensitive cytochalasin B binding of each of these membrane preparations by reducing the total number of the binding sites without affecting the dissociation constant. The reduction in total number of binding sites was analyzed as a function of radiation dose based on target theory, from which a radiation-sensitive mass (target size) was calculated. When the plasma membranes of insulin-treated adipocytes were used, a target size of approximately 58,000 daltons was obtained. For adipocyte microsomal membranes, we obtained target sizes of approximately 112,000 and 109,000 daltons prior to and after insulin treatment, respectively. In the case of ...

1987-06-15

170

Pricing of constraints - the England & Wales experience  

Energy Technology Data Exchange (ETDEWEB)

The existence, in real-time, of transmission constraints, demand forecasting errors, generator failures, and other factors impose additional costs through the need to run more expensive generation. These costs can appear as a significant component of the wholesale price to demand served by electricity markets operated over transmission networks. In the England & Wales Pool these costs are passed through directly to supply companies. The Transmission System Operator ({open_quotes}TSO{close_quotes}) can exert significant influence on these costs through improved availability of transmission circuits and through appropriate investment, but has no incentive to do so. Since the inception of the Pool, these costs have increased in level and volatility, and have proved difficult to hedge. In response, St Clements Services were instrumental in assisting Pool members to develop an {open_quotes}Uplift Incentive Management ...

1996-03-01

171

Fragmentation mechanisms of a single molten copper jet penetrating a sodium pool. Transition from thermal to hydrodynamic fragmentation in instantaneous contract interface temperatures below its freezing point  

International Nuclear Information System (INIS)

To clarify the fragmentation mechanism of a molten metallic fuel jet in a sodium pool under high-ejection-velocity conditions that correspond to the medium- and high-burnup conditions in the metallic fuel core of liquid-metal-cooled fast breeder reactors, a series of experiments with molten copper as a metallic fuel simulant and a sodium pool was carried out. Under low-ejection-velocity conditions in the range of an ambient Weber number (Wea) a ? 200, the size of the fragments is confirmed to be almost independent of the initial superheating of the jet. Furthermore, the size of the fragments agrees well with that evaluated using the Rayleigh-Taylor instability model, in which the fragment size is assumed to be equal to half the fastest growing wavelength. This result is qualitatively consistent with the characteristics that the molten jet column with large inertia force owing to the high ejection velocity, which transports enthalpy downwards, ...

2010-03-01

172

Carbon in boreal coniferous forest soil  

Energy Technology Data Exchange (ETDEWEB)

The working hypothesis of the research was that the soil of boreal forests is a large carbon store and the amount of C is still increasing in young soils, like in the forest soils of Finland, which makes these soils important sinks for atmospheric CO{sub 2}. Since the processes defining the soil C balance, primary production of plants and decomposition, are dependent on environmental factors and site properties, it was assumed that the organic carbon pool in the soil is also dependent on the same factors. The soil C store is therefore likely to change in response to climatic warming. The aim of this research was to estimate the C balance of forest soil in Finland and predict changes in the balance in response to changes in climatic conditions. To achieve the aim (1) intensive empirical experimentation on the density of C in different pools in the soil and on fluxes between the pools was done was done, (2) the effect of site ...

1996-12-31

173

Animal and human studies of a new /sup 99m/Tc labelled phosphine-isocyanide complex with possible applications to radionuclide ventriculography  

Energy Technology Data Exchange (ETDEWEB)

A new /sup 99m/Tc-phosphine-isocyanide complex with the general structure (/sup 99m/Tc (DEPE)/sub 2/(CNR)/sub 2/)/sup +/ has been synthesised and tested in animals and one human. In three animal species (rat, rabbit, dog), the complex is an efficient myocardial imaging agent, while in humans it remains in the blood pool. The complex is 100% protein bound in animals and humans, but whereas in humans it is attached to a 51.5 kdalton protein (probably prealbumin), in rabbits it appears to be bound to a larger macromolecule (M.W.>100 kdalton). The efficiency of the complex for blood pool labelling was tested in a human volunteer and compared with the standard in vivo red cell labelling technique with stannous pyrophosphate. A satisfactory radionuclide angiogram could be performed with less than 370 MBq of the complex. The count rate for the complex (cps/MBq) was 15% higher than that obtained with the labelled red cells and the absence of splenic ...

1987-04-01

174

A study of membrane protein defects and alpha hemoglobin chains of red blood cells in human beta thalassemia  

International Nuclear Information System (INIS)

The soluble pool of alpha hemoglobin chains present in blood or bone marrow cells was measured with a new affinity method using a specific probe, beta A hemoglobin chain labeled with ["3H]N-ethylmaleimide. This pool of soluble alpha chains was 0.067 #+-# 0.017% of hemoglobin in blood of normal adult, 0.11 #+-# 0.03% in heterozygous beta thalassemia and ranged from 0.26 to 1.30% in homozygous beta thalassemia intermedia. This elevated pool of soluble alpha chains observed in human beta thalassemia intermedia decreased 33-fold from a value of 10% of total hemoglobin in bone marrow cells to 0.3% in the most dense red blood cells. The amount of insoluble alpha chains was measured by using the polyacrylamide gel electrophoresis in urea and Triton X-100. In beta thalassemia intermedia the amount of insoluble alpha chains was correlated with the decreased spectrin content of red cell membrane and was associated with a decrease in ...

175

Thermal-hydraulic analysis following a safety flapper valve's fault for a pool-type research reactor  

International Nuclear Information System (INIS)

One of the characteristic safety features of a pool type research reactor is a safety flapper valve. The valve enables natural convection cooling mechanism in one of the following events. (a) Opening flapper valve promote decay heat removal following reactor's shutdown. (b) Also the valve is gravity driven. There is a possibility that the valve fails to open when it is required to do so. In the present paper the cooling characteristics of the core are analyzed for this event. A steady state study was performed for 5 MW power and 18 FE following a reactor shutdown. It is shown that enough margin exists to assure adequate reactor core cooling should the safety flapper valve fails to open. (authors)

176

Simulation of the New York Power Pool for dispatcher training  

Science.gov (United States)

This paper describes the simulation of the operating environment of the New York Power Pool (NYPP) within the Dispatcher Training Simulator facility at the New York State Electric and Gas Corporation (NYSEG). The NYSEG control center uses real-time data received from the NYPP control center to control its internal generation. In addition, the NYSEG dispatchers work very closely with the NYPP dispatchers. The exact emulation of the Generation Control functions of the NYPP EMS, and the associated data exchange with the NYSEG ECS, contribute greatly to the high degree of realism achieved in the NYSEG DTS facility. The accuracy of the power system simulation in the DTS has been validated against actual power system disturbances recorded at NYSEG.

1994-11-01

177

Pool critical assembly benchmark solutions using MCNP and THREEDANT  

Energy Technology Data Exchange (ETDEWEB)

Analyses of pressure vessel damage resulting from neutron irradiation have primarily relied on two-dimensional transport calculations and a spatial-synthesis methodology to accommodate three-dimensional effects in the results of two two-dimensional calculations. In this paper, the authors report on calculations made on the Pool Critical Assembly (PCA) Benchmark, Configuration 12/13, using the three-dimensional, continuous energy Monte Carlo transport code, MCNP, and the three-dimensional, multigroup, diffusion accelerated discrete ordinates transport code THREEDANT. Neutron fluxes and activation rates as determined from these two calculations are compared to each other and to experimental results in the literature. The authors also draw some conclusions on the value of 3D calculations on the interpretation of experimental results.

1994-12-31

178

Bidding strategy for pumped-storage plant in pool-based electricity market  

Energy Technology Data Exchange (ETDEWEB)

This paper develops optimal bidding strategies for a pumped-storage plant in a pool-based electricity market. In the competitive regime, when compared to simple hydroelectric generator, profit of the pumped-storage plant is maximized by operating it as a generator when market clearing price is high and as a pump when the price is low. Based on forecasted hourly market clearing price, a multistage looping algorithm to maximize the profit of a pumped-storage plant is developed, considering both the spinning and non-spinning reserve bids and meeting the technical operating constraints of the plant. The proposed model is adaptive for the nonlinear three-dimensional relationship between the power produced, the energy stored, and the head of the associated reservoir. Different operating cycles for a realistic pumped-storage plant are considered and simulation results are reported and compared. (author)

2010-03-15

179

Water Quality Criteria | Water Quality Criteria | US EPA  

Science.gov (United States)

for? Learn the Issues Science & Technology Laws & Regulations About EPA Contact Us Water: Water Quality Criteria You are here: Water Science & Technology Surface Water Standards &...

2011-08-28

180

Trusts : Directgov - Money, tax and benefits  

Wastenet

...events Completing the Trust and Estate Tax Return Completing and filing the trust tax return - filing online, avoiding common mistakes, tax return deadlines and penalties Trusts and Income Tax How different types of trust income are taxed, what management expenses and reliefs can be deducted, understanding the tax pool Trusts and Capital Gains Tax Capital Gains Tax exemptions and reliefs for trustees and notifying HMRC about a trust disposal or ...

181

The mutT Defect Does Not Elevate Chromosomal Fragmentation in Escherichia coli Because of the Surprisingly Low Levels of MutM/MutY-Recognized DNA Modifications?  

UK PubMed Central (United Kingdom)

Nucleotide pool sanitizing enzymes Dut (dUTPase), RdgB (dITPase), and MutT (8-oxo-dGTPase) of Escherichia coli hydrolyze noncanonical DNA precursors to prevent incorporation of base...Full Text Available

2007-10-01

182

Stable Isotope Labeling, in Vivo, of d- and l-Tryptophan Pools in Lemna gibba and the Low Incorporation of Label into Indole-3-Acetic Acid 1  

UK PubMed Central (United Kingdom)

We present evidence that the role of tryptophan and other potential intermediates in the pathways that could lead to indole derivatives needs to be reexamined. Two lines of Lemna gibba...Full Text Available

1991-04-01

183

NAME=\\  

Wastenet

... The moorland landscape looks especially colourful in late summer, while spring is the perfect time to come and see migrant birds like redstarts,...Valley This is a delightful oak woodland to walk through - especially in spring and early summer when lots of migrating birds come to breed ... Fowlmere Fowlmere's reedbeds and pools are fed by natural chalk springs, and a chalk stream runs through the reserve. Special birds ... There are common woodland birds in spring and turtle doves in spring and summer. Haweswater If you want to see a golden ...

184

Monte Carlo design calculations for a neutron imaging facility collimator  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for computed tomography and real-time neutron radiography is being developed at the University of Texas at Austin. The TRIGA reactor is a graphite-reflected Mark It pool-type research reactor. The neutron imaging facility will use beam port, which is at one end of a through part. Monte Carlo calculations were used to design the neutron collimator for this facility.

1996-12-31

185

Immunocytochemical techniques reveal multiple, distinct cellular pools of PtdIns4P and PtdIns(4,5)P2  

UK PubMed Central (United Kingdom)

PtdIns4P is the major precursor for the synthesis of the multifunctional plasma membrane lipid, PtdIns(4,5)P2. Yet PtdIns4P also functions...Full Text Available

2009-08-15

186

Construction of a genome-wide human BAC-Unigene resource. Final progress report, 1989--1996  

Energy Technology Data Exchange (ETDEWEB)

Currently, over 30,000 mapped STSs and 27,000 mapped Unigenes (non-redundant, unigene sets of cDNA representing EST clusters) are available for human alone. A total of 44,000 Unigene cDNA clones have been supplied by Research Genetics. Unigenes, or cDNAs are excellent resource for map building for two reasons. Firstly, they exist in two alternative forms -- as both sequence information for PCR primer pairs, and cDNA clones -- thus making library screening by colony hybridization as well as pooled library PCR possible. The authors have developed an efficient and robust procedure to screen genomic libraries with large number of DNA probes. Secondly, the linkage and order of expressed sequences, or genes are highly conserved among human, mouse and other mammalian species. Therefore, mapping with cDNA markers rather than random anonymous STSs will greatly facilitate comparative, evolutionary studies as well as physical map building. They have currently deconvoluted ...

1996-12-31

187

Characterization of Auxin Conjugates in Arabidopsis. Low Steady-State Levels of Indole-3-Acetyl-Aspartate, Indole-3-Acetyl-Glutamate, and Indole-3-Acetyl-Glucose1  

UK PubMed Central (United Kingdom)

Amide-linked indole-3-acetic acid (IAA) conjugates constitute approximately 90% of the IAA pool in the dicot Arabidopsis, whereas ester-linked conjugates and free IAA account for approximately...Full Text Available

2000-06-01

188

Ancillary Services in a pool-based competitive market: Conference on innovative approaches to electricity pricing  

Energy Technology Data Exchange (ETDEWEB)

(1) Most ancillary services needed for real-time control of the transmission grid and to meet operating criteria can be competitively supplied and competitively procured. (2) The independent service operator (ISO) must directly control the generators and loads, which supply ancillary services. (3) Comparability of access to ancillary services is achievable through the ISO-based competitive market structure.

1996-03-01

189

Analysis of the MEX-15 multipurpose reactor using SRAC code system  

Energy Technology Data Exchange (ETDEWEB)

The MEX-15 is a conceptual design of a Multipurpose Reactor with thermal power of 15 MW and this reactor is pool type with fuel plates U{sub 3}0{sub 8}-Al of low enrichment uranium. This report presents the static calculation for the MEX-15 reactor using SRAC code system and was developed under the collaboration agreement between ININ-JAERI in Research Reactor Technology Development Division of Department of Research Reactor in Tokai Research Establishment. (Author)

1992-12-15

190

A thermal valve heat flux control device  

International Nuclear Information System (INIS)

In order to evacuate the residual power in a nuclear reactor, a thermal valve system is presented for the modification of the heat exchange conditions at the pool exchanger level, which avoids the use of mechanical valves on the pipes. The system involves a vessel containing the exchanger, with openings at the upper end of the vessel and means for feeding the fluid at the lower end, and means for controlling the opening width.

1994-10-05

191

Individual Radiation Protection Monitoring in the Marshall Islands: Rongelap Atoll (2002-2004)  

Energy Technology Data Exchange (ETDEWEB)

The United States Department of Energy (U.S. DOE) has recently implemented a series of strategic initiatives to address long-term radiological surveillance needs at former U.S. nuclear test sites in the Marshall Islands. The plan is to engage local atoll communities in developing shared responsibilities for implementing radiation protection monitoring programs for resettled and resettling populations in the northern Marshall Islands. Using the pooled resources of the U.S. DOE and local atoll governments, individual radiological surveillance programs have been developed in whole body counting and plutonium urinalysis in order to accurately assess radiation doses resulting from the ingestion and uptake of fallout radionuclides contained in locally grown foods. Permanent whole body counting facilities have been established at three separate locations in the Marshall Islands including Rongelap Atoll (Figure 1). These facilities are operated and maintained by ...

2006-01-17

194

Photocatalytic oxidation and reduction chemistry and a new process for treatment of pink water and related contaminated water  

Energy Technology Data Exchange (ETDEWEB)

The objective of this project was to develop new photocatalytic or other innovative process chemistry for the treatment of pink water and related contaminated water.

1996-10-01

195

Large eddy simulation of pulsating pool fire  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: General simulation objectives of any fire analysis are macroscopic in nature and deals with the grass data in respect of fire/smoke spread, structural behaviour, environmental conditions etc. However, the accuracy of predicting such macroscopic parameters is a strong function of several other microscopic parameters which govern the overall macroscopic behaviour. Some of the microscopic parameters of interesting such analysis could be buoyancy induced stable/unstable flows, relative flame behaviour, baroclinic velocity distribution etc. Only the field based fire modelling approach is capable of calculating several of these by way of detailed CFD based field modelling. One of the best known tool that could be employed for such studies is the Fire Dynamics simulator (FDS) from NIST with its popular LES based fire modelling approach. Advanced LES based fire modelling scores over the conventional RANS based Computational fire modelling but it is ...

2005-07-01

196

Limits of the simulation of a nuclear fuel pin by an electrically heated rod  

Energy Technology Data Exchange (ETDEWEB)

The utilization of electrically heated rods for the simulation of nuclear fuel pins represents a generally adopted method by the nuclear industry to study thermalhydraulic problems. Usually its is necessary to determine the time variation of the electric linear power to simulate a given nuclear power transient in order to yield the same temperature and heat flux conditions in the surface of the electrical heater that would be observed in the nuclear fuel pin. The present work analyzes the limits of the usually adopted simulation methods and shows a manner to obtain the required electrical linear power that reduces oscillations and yields accurate results for the thermal conditions of the rod surface wall. (author). 5 refs, 5 figs, 1 tab.

1992-12-31

197

Limits of the simulation of a nuclear fuel pin by an electrically heated rod  

International Nuclear Information System (INIS)

The utilization of electrically heated rods for the simulation of a nuclear fuel pins represents a generally adopted method by the nuclear industry to study thermalhydraulic problems. Usually, it is necessary to determine the time variation of the electric linear power to simulate a given nuclear power transient in order to yield the same temperature and heat flux conditions in the surface of the electrical heater that would be observed in the nuclear fuel pin. The present work analyses the limits of the usually adopted simulation methods and shows a manner to obtain the required electrical linear power that reduces oscillations and yields accurate results for the thermal conditions of the rod surface wall. (author) 5 refs., 5 figs., 1 tab.

1992-12-01

198

Instabilities in Focused Ion Beam-patterned Au nanowires  

British Library Electronic Table of Contents (United Kingdom)

Focused Ion Beam (FIB) technology has become an indispensable enabling tool for micro nano fabrications. One important application is to use FIB for patterning conducting nanowires of metals down to a few tens of nanometre for applications such as interconnects, heaters and temperature nanosensors. A series of experiments on Au nanowires fabricated by FIB on SixNy membrane show that nanowires with width 50nm have structural instabilities. These are liquid like and first show-up as undulations in nanowire width with clearly defined wave lengths. For smaller widths (20nm) the instabilities grow and the wires eventually break-up into spherical balls. Further experiments show that the nanowires can be made stable to smaller widths by the use of a Cr underlayer to enhance surface wetting. The o...

2011-01-01

199

Impact of Tubing Length on Hemodynamics in a Simulated Neonatal Extracorporeal Life Support Circuit  

British Library Electronic Table of Contents (United Kingdom)

Abstract During extracorporeal life support (ECLS), a large portion of the hemodynamic energy is lost to various components of the circuit. Minimization of this loss in the circuit leads to better vital organ perfusion and decreases the risk of systemic inflammation. In this study, we evaluated the hemodynamic properties of differing lengths of tubing in a simulated neonatal ECLS circuit. The neonatal ECLS circuit used in this study included a Capiox Baby RX05 oxygenator (Terumo Corporation, Tokyo, Japan), a Rotaflow centrifugal pump (MAQUET Cardiopulmonary AG, Hirrlingen, Germany), and a heater and cooler unit. An 8 Fr Biomedicus arterial and a 10 Fr Biomedicus venous cannula were connected to the pseudopatient. One fourth inch tubing was used for both the arterial and the venous line. A ...

2010-01-01

200

Gas Appliance Technology Center: Annual report, January-December 1986  

Energy Technology Data Exchange (ETDEWEB)

The report reviews the activity during the fourth year of Gas Research Institute's Gas Appliance Technology Center program. Work on gas appliances involved a conceptual table-top multi-function oven, development of an indirect-fired conveyor oven, and performance comparisons of smooth cooktops. Performance-evaluation methods for commercial ovens were evaluated. Design improvements were made to a direct-fired conveyor oven and a pulse-combustion deep-fat fryer. Performance of common vents were studied, and a device was designed to allow incorporation of appliances with positive vent pressures into such systems. Standards-related work included draft-hood capacities, flexible corrugated-connector corrosion, and sediment trap efficiencies. Heating-related work comprised conceptual design of a vented baseboard heater and a centralized heat-transfer fluid system.

1987-08-01

201

Full-scale model of cooling and heating system for JT-60 vacuum vessel  

Science.gov (United States)

A full-scale model of a rigid sectorial ring and a set of bellows which was covered with a temperature control layer and a coolant supply equipment was constructed to verify the adequacy of the heating and cooling system designed for JT-60. To cool and heat it effectively and to decrease the temperature differences among the various parts in the vacuum vessel, heater units and cooling pipes were located on the surface of the ring. The temperature control layer is to heat the vessel to 500/degree/sub //C within 70 hours and to maintain it at the temperature for 48 hours for simulating the state of bakeout. Subsequently the vessel is cooled down within about the same time as in heating. Prior to the series of tests, numerical analyses were performed to predict the cooling and heating efficiencies on the model and to examine the method of the temperature regulation.

1981-01-01

202

Experimental modelling of thermal consolidation effects around a high level waste repository  

International Nuclear Information System (INIS)

This report summarizes the results of a research programme which involves the development of a laboratory experimental facility for the simulation and study of hydro-thermo-mechanical processes in saturated geomaterials with low permeability. The experimentation involves a synthetic cement based porous material made of cement grout which possesses permeabilities in the range of dense unfractured sandstones or shale. Specially manufactured pore-pressure transducers were installed within the cylindrical block at locations adjacent to a plane free boundary. The block was saturated with the periodic application of a vacuum. In its saturated state the plane boundary of the block was subjected to heating via a circular heater the temperature of which was maintained constant. The resulting pore pressure generation along with temperature at these locations was monitored continuously. The results of a series of experiments are documented and further extensions to the ...

203

Evaluation of Neonatal Membrane Oxygenators With Respect to Gaseous Microemboli Capture and Transmembrane Pressure Gradients  

British Library Electronic Table of Contents (United Kingdom)

Abstract A series of studies performed at our center demonstrates that gaseous microemboli (GME) remain a challenge in cardiac surgical procedures. Evaluation of novel oxygenators must address hemodynamic parameters and microemboli capture capability. The objective of this study is to compare two neonatal membrane oxygenators, the Quadrox i (MAQUET Cardiopulmonary AG, Hirrlingen, Germany) and the Capiox RX05 (Terumo Corporation, Tokyo, Japan), with respect to GME capture and hemodynamic energy delivery. The experimental circuit included a Maquet HL 20 heart lung machine, a Heater Cooler Unit HCU 30 (MAQUET Cardiopulmonary AG), a membrane oxygenator (Quadrox i Neonatal or Capiox RX05), and inch tubing from the COBE Heart/Lung Perfusion Pack (COBE Cardiovascular, Inc., Arvada, CO, USA). A Ca...

2010-01-01

204

A miniaturized spatial temperature gradient capillary electrophoresis system with radiative heating and automated sample introduction for DNA mutation detection  

British Library Electronic Table of Contents (United Kingdom)

Abstract A miniaturized spatial temperature gradient CE system with automated sample introduction for DNA mutation detection was established. Continuous electrokinetic sample injection was achieved by combining an automated slotted vial array sample introduction device to the spatial temperature gradient CE system. The temperature gradient was produced by a radiative heating system with a single graphite block heater, and the stability of the temperature gradient was investigated. The temperature variation of each measure point was 0.12 0.21% RSD (n=7) within 6 h. A 14 cm Teflon AF coated silica capillary was used both as the separation channel and as the liquid core waveguide tube of fluorescence signal. Under a temperature gradient from 54.8 to 59.5 C, a low range control mutation standa...

2010-01-01

205

Water resources data for Oklahoma, water year 1992. Volume 2. Red River Basin. Water-data report (Annual), 1 October 1991-30 September 1992  

Energy Technology Data Exchange (ETDEWEB)

Volume 2 of the water resources data for the 1992 water year for Oklahoma consists of record of stage, discharge, and water quality of streams; stage, contents, and water quality of lakes or reservoirs; and water levels of ground-water well. The report contains discharge records for 136 gaging stations; stage and contents for 31 lakes or reservoirs; water quality for 50 gaging stations. Also included are 61 partial-record or miscellaneous streamflow stations and 28 ground-water sites.

1993-04-01

206

Safe Water in an Emergency  

Medline Plus

English - Safe Water in an Emergency Click to Stop Video Click to Start Video To Listen to ...

207

Improving cost-effectiveness for the furnace in a full-scale refinery plant with reuse of waste tail gas fuel  

Energy Technology Data Exchange (ETDEWEB)

The waste tail gas fuel emitted from refinery plant in Taiwan e.g. catalytic reforming unit, catalytic cracking unit and residue desulfurization unit, was recovered and reused as a replacement fuel. In this study, it was slowly added to the fuel stream of a heater furnace to replace natural gas for powering a full-scale distillation process. The waste tail gas fuel contained on average 60 mol% of hydrogen. On-site experimental results show that both the flame length and orange-yellowish brightness decrease with increasing proportion of waste gas fuel in the original natural gas fuel. Moreover, the adiabatic flame temperature increases as the content of waste gas fuel is increased in the fuel mixture since waste gas fuel has a higher adiabatic flame temperature than that of natural gas. The complete replacement of natural gas by waste gas fuel for a heater furnace operating at 70% loading (i.e. 3.6 x 10{sup 7} kcal/h of combustion capacity) will ...

2010-02-15

208

Gas fired heaters and ventilation system improve indoor air quality and thermal comfort  

Energy Technology Data Exchange (ETDEWEB)

Rotex Inc. has designed and manufactured industrial sifting equipment since 1844. This site (an existing industrial facility) encompasses approximately 140,000 ft[sup 2] (13,006 m[sup 2]) of offices, R D shops, assembly and storage areas, as well as a large welding shop that was the main focus of this project. This facility consists of three separate buildings that are all connected and open to one another. The original building dates from 1908. The newest addition (32,400 ft[sup 2]; 3,010 m[sup 2]) was added in 1977, and is referred to as the 77 Building. This building was initially equipped with oil fired heating equipment due to the moratorium on new gas sales that was in effect at that time. This project was driven by the client's need to remove underground oil storage tanks to comply with environmental standards. This article describes the 77 Building conversion from oil to an environmentally cleaner fuel, natural gas. Existing heaters were removed ...

1994-03-01

209

Analyses of mixed hydrocarbon binary thermodynamic cycles for moderate temperature geothermal resources  

Energy Technology Data Exchange (ETDEWEB)

A number of binary geothermal cycles utilizing mixed hydrocarbon working fluids were analyzed with the overall objective of finding a working fluid which can produce low-cost electrical energy using a moderately low temperature geothermal resource. Both boiling and supercritical shell-and-tube cycles were considered. The performance of a dual-boiling isobutane cycle supplied by a 280/sup 0/F hydrothermal resource (corresponding to the 5MW pilot plant at the Raft River site in Idaho) was selected as a reference. To investigate the effect of resource temperature on the choice of working fluid, several analyses were conducted for a 360/sup 0/F hydrothermal resource, which is representative of the Heber resource in California. The hydrocarbon working fluids analyzed included methane, ethane, propane, isobutane, isopentane, hexane, heptane, and mixtures of those pure hydrocarbons. For comparison, two fluorocarbon refrigerants were also analyzed. Preliminary estimates of relative heat ...

1981-01-01

210

Thermal Interaction Between Molten Metal Jet and Sodium Pool: Effect of Principal Factors Governing Fragmentation of the Jet  

International Nuclear Information System (INIS)

To clarify the effects of the principal factors that govern the thermal fragmentation of a molten metallic fuel jet in the course of fuel-coolant interaction, which is important in evaluating the sequence of core disruptive accidents (CDAs) for metallic fuel fast reactors, basic experiments were carried out using molten metallic fuel simulants (copper and silver) and a sodium pool.Fragmentation of a molten metal jet with a solid crust was caused by internal pressure produced by the boiling of sodium, which is locally entrapped inside the jet due to hydrodynamic motion between the jet and the coolant. The superheating and the latent heat of fusion of the jet are the principal factors governing this type of thermal fragmentation. On the other hand, the effect of the initial sodium temperature is regarded as negligible in the case of thermal conditions expected to result in CDAs for practical metallic fuel cores. Based on the fragmentation data for several kinds of ...

2005-02-01

211

Sensitivity Study for CFD Analysis on Debris Transport to ECCS Sump for CANDU Type Plant in Korea  

International Nuclear Information System (INIS)

Once containment recirculation pumps are activated and emergency core cooling (ECC) flow is supplied from the recirculation sump during loss of coolant accident (LOCA), various insulations and coatings on a pipe, equipments and structures damaged by LOCA break jet as well as additional debris sources are transported to recirculation sump screen by the break flow and containment spray flow drainage. This debris may result in loss of net pressure suction head (NPSH) of the recirculation pumps, and have a threat to long term cooling and containment heat removal capacity. In this case, flow patterns of containment pool are important to confirm behaviors of debris transport for predicting various flow paths to the recirculation sump screen. In this paper, models using commercial computational fluid dynamics (CFD) software CFX are developed for containment pool simulation during recirculation mode. The specific plant used for this analysis is CANDU ...

2010-10-01

212

Photoelectrochemistry of disordered passive films  

Energy Technology Data Exchange (ETDEWEB)

A theoretical model, which describes subband gap photoexcitation involving localized electronic states, was developed. The escape probability of a charge carrier trapped in a localized state is considered via Poole-Frenkel, direct tunneling, or phonon-assisted tunneling processes, as competing escape mechanisms. Photoelectrochemical experiments were performed on the passive films formed on zirconium and amorphous iron-zirconium alloys and on pure HfO/sub 2/ films and HfO/sub 2/ films implanted with varying concentrations of xenon. These films were found to possess some degree of disorder depending on the substrate, the thickness of the film, and the extent of implantation. The spectral dependence of the photocurrent in all of the films studied is considerably different from what was found for crystalline passive films. The potential dependence of the photocurrent yields Poole-Frenkel behavior. Reverse tunneling processes were also observed at ...

1987-01-01

213

Abundance of West Nile virus mosquito vectors in relation to climate and landscape variables.  

Science.gov (United States)

It is currently unclear if the potential for West Nile virus transmission by mosquito vectors in the eastern United States is related to landscape or climate factors or both. We compared abundance of vector species between urban and suburban neighborhoods of Henrico County, VA, in relation to the following factors: temperature, precipitation, canopy cover, building footprint, and proximity to drainage infrastructure. Mosquitoes were collected throughout the 2005, 2006, and 2007 seasons and tested for West Nile virus (WNV) in pools of 10-50. Test results of mosquito pools were compared to average site abundance from 37 sites in Henrico County, VA; abundance was then examined in relation to ecological variables. Urban infrastructure was positively correlated with the abundance of Culex pipiens L./Cx. restuans, and our findings implicate combined sewer overflow systems as large contributors to Culex vector populations. No measure of urbanization ...

2011-06-01

214

The requirements for a sustainable restoration project  

Energy Technology Data Exchange (ETDEWEB)

The purpose is to describe problems associated with the establishment of vegetation on mined lands and practical rehabilitation and restoration methods for establishing a rehabilitation plan. Land disturbed by mining should be restored to its original state, when the mine is decommissioned, but before that can be attained, site problems such as toxicity, moisture supply, and texture must be rectified. The land may need to pass through several conditioning stages, and links need to be formed to maintain a functioning ecosystem. A key aspect to rehabilitation is the need to increase the organic matter content of the substrate. This improves soil structure, increases the moisture holding ability, and provides a pool for nutrient cycling. 11 refs., 2 tabs.

1991-06-01

215

Shredders and riparian vegetation  

Energy Technology Data Exchange (ETDEWEB)

Stream invertebrates that feed on leaf litter are intimately tied to the nature and timing of the litter input. These invertebrates are called shredders; they consume streamside, riparian litter that has become trapped in the stream channel. This plant litter accumulates at the leading edge of obstructions in the current and settles out in pools, alcoves, and other depositional zones. Given the extensive literature that has accumulated over the last 20 years, researchers can now develop a general, testable model that relates riparian plant communities to the stream shredders, which depend upon litter derived from those communities.

1989-01-01

216

Joint effect of financial fragility and macroeconomic shocks on bank loan losses: Evidence from Europe  

British Library Electronic Table of Contents (United Kingdom)

A reduced-form model including nonlinearities is estimated from pooled data from nine European countries during 1982-2004 to show the effects of macroeconomic shocks and financial fragility on bank loan losses. The main ingredients of the model are unanticipated-output and interest-rate shocks estimated from published macroeconomic and naive forecasts. The model fits the data well, capturing the extremely high levels of loan losses witnessed in different financial crises.

2011-01-01

217

Forward contracts in electricity markets: The Australian experience  

International Nuclear Information System (INIS)

Forward contracts play a vital role in all electricity markets, and yet the details of the market for forward contracts are often opaque. In this paper we review the existing literature on forward contracts and explore the contracting process as it operates in Australia. The paper is based on interviews with participants in Australia's National Electricity Market (NEM). The interviews were designed to understand the contracting process and the practice of risk management in the Australian energy-only pool market. This survey reveals some significant gaps between the assumptions made in the academic literature and actual practice in the Australian market place. (author)

2007-05-01

218

Congestion cost allocation method in a pool model  

International Nuclear Information System (INIS)

The congestion cost caused by transmission capacities and voltage limit is an important issue in a competitive electricity market. To allocate the congestion cost equitably, the active constraints in a constrained dispatch and the sequence of these constraints should be considered. A multi-stage method is proposed which reflects the effects of both the active constraints and the sequence. In a multi-stage method, the types of congestion are analysed in order to consider the sequence, and the relationship between congestion and the active constraints is derived in a mathematical way. The case study shows that the proposed method can give more accurate and equitable signals to customers. (Author)

2003-09-01

219

Assessment of cooling effects on extending the maximum operating time for the Syrian Miniature Neutron Source Reactor  

International Nuclear Information System (INIS)

Various schemes of cooling have been investigated for the purpose of assessing potential benefits on the operational characteristics of the Syrian MNSR reactor. A detailed thermal hydraulic model for the analysis of MNSR has been developed. The analysis shows that an auxiliary cooling system, installed in the pool which surrounds the lower section of the reactor vessel, will significantly offset the consumption of excess reactivity due to the negative reactivity temperature coefficient, Hence, the maximum operating time of the reactor is extended. Compared with experimental data, the suggested model proves to be valid for the analysis of MNSR behavior under both steady state and transient conditions. (author)

2007-01-01

220

TRIGA reactor spent fuel pool under severe earthquake conditions  

International Nuclear Information System (INIS)

Supplemental criticality safety analysis of a pool type storage for TRIGA spent fuel at 'Jozef Stefan' Institute in Ljubljana, Slovenia, is presented. Previous results (Ravnik, M, Glumac, B., 1996) have shown that subcriticality is not guaranteed for some postulated accidents. To mitigate this deficiency, a study was made about replacing a certain number of fuel elements in the rack with absorber rods (Glumac, B., Ravnik, M., Logar, M., 1997) to lower the supercriticality probability, when the pitch is decreased to contact (as a consequence of a severe earthquake) in a square arrangement. The criticality analysis for the hexagonal contact pitch is presented in this paper, following the same scenario as outlined above. The Monte Carlo computer code MCNP4B with ENDF-B/VI library and detailed three dimensional geometry was used. First, the analysis about the influence of the number of triangular fuel piles on the bottom that could appear, if the fuel rack, made of ...

1998-07-01

221

Assessment of left ventricular wall motion by optional multiple long-axial gated blood pool SPECT  

International Nuclear Information System (INIS)

Optional multiple long-axial gated blood pool SPECT images were prepared for the purpose of stereoscopic and quantitative imaging of left ventricular wall motion (LVWM). Sixteen patients with ischemic heart disease and 8 healthy subjects were imaged in 32 views in the 360 degrees position after iv injection of 740 MBq of Tc-99m-labeled human serum albumin D. The R-R interval was divided into 16. After preparing conventional oblique images, long-axial images were prepared. Shortening rate of left ventricular wall was calculated in 5 segments of the apex and base of the left ventricle. An average shortening rate in each segment was graded with a score from a minimum of 0 to a maximum of 40% or more. In the normal group, shortening rate in each segment, except for the base of the septal region, exceeded 40%. In the group of ischemic heart disease, radial shortening was capable of visualizing the degree and extent of the whole LVWM abnormality. LVWM abnormality seen on ...

1991-01-01

222

Analysis of enclosed sodium pool fire scenario in sodium fire experimental facility  

International Nuclear Information System (INIS)

Liquid sodium is used as coolant in Fast Breeder Reactors (FBR). There is a likelyhood of sodium spillage in ambient air in the Steam Generator Building (SGB) of the FBR plant. Due to high chemical reactivity with oxygen, especially at temperatures greater than 573 K, it catches fire very easily. In order to carryout safety related experimental studies for different modes of sodium fires and to develop suitable mathematical models for the assessment of their consequences, an experimental facility (SFEF, Sodium Fire Experimental Facility) is being setup a IGCAR, Kalpakkam. The SFEF is having a 540 m"3 volume experimental hall. Stainless steel linear will be provided on the inside surfaces of experimental hall walls, ceiling and floor. Analysis has been carried out for enclosed sodium pool fire scenarios in SFEF by using sodium pool fire code SOFIRE II, which estimates the thermal transients like pressure rise, gas temperature rise, cell wall ...

2007-04-22

223

Water resources data for Minnesota, water year 1993. Volume 2. Upper Mississippi and Missouri River basins. Water-data report (Annual), 1 October 1992-30 September 1993  

Energy Technology Data Exchange (ETDEWEB)

Water-resources data for the 1993 water year for Minnesota consists of records of stage, discharge and water quality of streams; stage, contents, and water quality of lakes and reservoirs; and water levels and water quality in wells and springs. This volume contains discharge records for 58 gaging stations; stage and contents for 9 lakes and reservoirs; water quality 15 stream stations, 1 lakes station, 1 precipitation station, and water levels for 15 observation wells. Also included are 61 high-flow partial-record stations. Additional water data were collected at various sites, not part of the systematic data collection program and are pulished as miscellaneous measurements.

1994-07-01

224

Water resources data for Minnesota, water year 1991. Volume 2. Upper Mississippi and Missouri River Basins. Water-data report (Annual), 1 October 1990-30 September 1991  

Energy Technology Data Exchange (ETDEWEB)

Water-resources data for the 1991 water year for Minnesota consist of records of stage, discharge and water quality of streams; stage, contents, and water quality of lakes and reservoirs; and water levels and water quality in wells and springs. The volume contains discharge records for 60 gaging stations; stage and contents for 9 lakes and reservoirs; water quality for 18 stream stations, 1 lake station, 22 partial-record sites, 1 precipitation station, 108 wells; and water levels for 119 observation wells. Also included are 59 high-flow partial-record stations. Additional water data were collected at various sites, not part of the systematic data collection program and are published as miscellaneous measurements or low-flow investigations.

1992-09-01

225

National Water Plan draft  

International Nuclear Information System (INIS)

In the National Water Plan it is described which measures must be taken to keep the Netherlands safe and livable for future generations and to make use of the chances offered by water.

226

CDC Data & Statistics | Feature: Drowning Risks in Natural Water...  

Science.gov (United States)

swimmers in or around the water. Designate a responsible adult who can swim and knows CPR to watch swimmers in or around water. The supervisor should not be involved in any...

2011-09-24

227

Ecological response of a multi-purpose river development project using macro-invertebrates richness and fish habitat value  

International Nuclear Information System (INIS)

It has been acknowledged that river morphology and hydrology have been intensively altered due to the anthropic demands in floodplain land use and management, flood protection, promotion of navigability or energy production. Rivers were transformed in water highways, having lost contact with their surrounding floodplain as well as the plethora of ecological processes and occupants once thriving in these ecotonal zones. The identification of this emerging threat of morphological and hydrological alteration on ecological integrity adds further complexity in the exploitation of hydrosystem resources. These resources are heavily coveted and guarded by different lobbies each having strategic views on future project development. Stakeholders may want to promote hydro-electricity, ecologists a natural reserve, communes may wish to have an increased flood protection and leisure promoters a nautical center. As a result, the proposition of a river development project is ...

2002-04-01

232

Turbidimetric determination of sulfite ion in inhibited ethylene glycol-water solutions  

Science.gov (United States)

Turbidimetric method for determining sulfite in inhibited ethylene glycol-water solutions

1970-01-01

233
234

REPORT NO. 853  

Science.gov (United States)

water and of the ethylene glycol-water solutions are shown as functions of temperature in figures 4 and 5, respectively. (data from reference 4). ...

235

Process for reducing the water content of coal containing bound water  

Energy Technology Data Exchange (ETDEWEB)

An improved process is disclosed for reducing the water content of coal containing bound water by releasing at least a portion of the bound water by maintaining the coal at a temperature from about 220/sup 0/ to about 500/sup 0/ F. in the presence of water at a pressure sufficient to maintain at least portion of the water in a liquid phase for a time sufficient to release at least a portion of the bound water wherein the improvement comprises contacting the coal during such treatment with an active material selected from the group consisting of carboxylic organic acids containing up to about 6 carbon atoms, phenol, phenolic acids and inorganic acids.

1983-08-23

236

Implementation of the national desalination and water purification technology roadmap : structuring and directing the development of water supply solutions.  

Energy Technology Data Exchange (ETDEWEB)

In the United States, economic growth increasingly requires that greater volumes of freshwater be made available for new users, yet supplies of freshwater are already allocated to existing users. Currently, water for new users is made available through re-allocation of xisting water supplies-for example, by cities purchasing agricultural water rights. Water may also be made available through conservation efforts and, in some locales, through the development of ''new'' water from non-traditional sources such as the oceans, deep aquifer rackish groundwater, and water reuse.

2006-06-01

237

Energy and Water Conservation  

Science.gov (United States)

Jet Propulsion Laboratory. California Institute of Technology. Pasadena, California. Energy and Water Conservation. Steve Rigdon. Facilities Energy Manager ...

238

Combustible Water Repellent Coating.  

Science.gov (United States)

... Descriptors : *Combustible cartridge cases, *Water repellents, *Protective coatings, *Patents, Silica gel, Aluminum compounds, Binders ...

1973-07-24

239

User's guide on butt heat-fusion joining of polyethylene gas pipes. Topical report, July 1986-September 1989. Volume 1  

Energy Technology Data Exchange (ETDEWEB)

Heat fusion is the most common joining method for polyethylene gas distribution piping. Butt fusion was studied with the intent of relating the quality of the joint to the joining conditions. A semi-empirical approach was used. The thermofluid consequences of joining conditions such as heater temperature, heating time and joining parameter were calculated using a computer model. The model was validated by instrumented tests. The strength of the joints was gauged by destructive mechanical testing. Tensile and tensile impact tests were used. Over 150 joints were fabricated using four different polyethylene resins. Most of the data are given in GRI Report No. 88/0276.2 -- Volume 2: Technical Reference on Butt Heat Fusion Joining of Polyethylene Gas Pipes. A parameter, termed the Joining Parameter, was found to characterize the joining conditions. Of the mechanical tests parameters, the impact energy was found to have the best correlation with the joining parameter. ...

1989-09-01

240

The effect of heat transfer augmentation on two-phase flow instabilities in a vertical boiling channel  

International Nuclear Information System (INIS)

Experimental and theoretical work have been carried out to find out the effects of heat transfer augmentation on two-phase flow instabilities in a single channel system. The effect of mass flow rate, heat input and inlet subcooling on the system behavior is studied using Freon-11 as the test fluid and six different heater surfaces are tested at various experimental conditions. Experimental evaluation is done using the steady-state pressure drop versus mass flow rate curves along with the curves of additional inlet pressure drop required to stabilize the system during the oscillations, and tables generated using the experimental data. Homogeneous equilibrium flow model and finite differences are used in theoretical analysis. An empirical relationship is obtained to calculate the pressure drop across the exit restriction. Characteristic equation for the system is found by linearizing the dynamic equations of the overall system and analyzed to determine the ...

1985-11-01

241

Technical reference on butt heat-fusion joining of polyethylene gas pipes. Topical report, July 1986-September 1989. Volume 2  

Energy Technology Data Exchange (ETDEWEB)

Heat fusion is the most common joining method for polyethylene gas distribution piping. Butt fusion was studied with the intent of relating the quality of the joint to the joining conditions. A semi-empirical approach was used. The thermofluid consequences of joining conditions such as heater temperature, heating time and joining parameter were calculated using a computer model. The model was validated by instrumented tests. The strength of the joints was gauged by destructive mechanical testing. Tensile and tensile impact tests were used. Over 150 joints were fabricated using four different polyethylene resins. Most of the data are given in GRI Report No. 88/0276.2 -- Volume 2: Technical Reference on Butt Heat Fusion Joining of Polyethylene Gas Pipes. A parameter, termed the Joining Parameter, was found to characterize the joining conditions. Of the mechanical tests parameters, the impact energy was found to have the best correlation with the joining parameter. ...

1989-09-01

242

Study on the technology of Chinese partially gasified coal fired combined cycle with a CFBC with different speeds  

Energy Technology Data Exchange (ETDEWEB)

In the research of a more efficient, less costly, more environmentally responsible and less technically difficult method for generating electrical power from coal, `the Partially Gasified Coal Fired Combined Cycle with a CFBC with Different Speeds (DFBC)` is introduced by Tsinghua University. The high efficiency cycle includes gasification, compressed air heating in a fluidized bed immersed air heater followed by a combustor and the heat recovery of gas turbine exhausted gas used as the combustion of coal in the differential-velocity atmospheric circulating fluidized bed. Superheated steam is raised in the DFBC boiler. A preliminary analysis is made for the choice of combined cycle components. The computer program can be used to evaluate the design and off-design performance of the power plant. The simulation results show that the new system is a valuable coal fired combined cycle system for China, mainly to the improvement of the existing power plants. (orig.)

1996-12-31

243

Study of exhaust and noise emissions reduction on a single spray direct injection diesel engine  

Energy Technology Data Exchange (ETDEWEB)

In order to materialize the automobile use small direct injection diesel engine (DI), the reduction in both exhaust emission and noise, as studied, was explained in summary. The DI, as excellent in fuel consumption characteristics, was studied to be adopted to the small automobile, with the materialization of small DI to be about 600cc in capacity per cylinder. However the further diminution in dimension had not been materialized yet, because of the aggravation in exhaust emission and vibration noise. Then a single spray DI, characterized by the approximate sphericity in shape of combustion chamber and adoption of cast iron made piston and two-stage spring nozzle, was prototypically made, with optimizing the combustion in characteristics, decreasing HC in exhaust quantity by modifying the injection system, doing also NOx in exhaust quantity by adopting the lag angle at injection time and EGR, modifying the structure to lower the noise, and adopting an air heater to ...

1989-04-01

244

Lubrication properties of molybdenum disulfide films deposited by RF sputtering method  

Energy Technology Data Exchange (ETDEWEB)

A radio frequency sputtering apparatus with a pair of targets has been developed for depositing a film of uniform thickness onto a complex-geometric specimen such as the retainer of a ball bearing. The deposition characteristics of the apparatus were compared with those of the conventional sputtering apparatus. Lubrication properties of MoS/sub 2/ films made by these devices were also compared under a variety of conditions. Finally, friction and wear of MoS/sub 2/ films applied to angular-contact type ball bearings of 20 mm bore were studied in air, nitrogen and vacuo. The two-target sputtering has an advantage mentioned above. However, the films deposited by the method exhibited a rather short wear life because of the temperature rise of the substrate during ion bombardment and during the sputtering process. This temperature dependence was observed in films on those substrates that had been heated with a built-in heater during sputtering. The film thickness ...

1986-01-01

245

Lining of magnesium alloys with foils using shot peening  

Energy Technology Data Exchange (ETDEWEB)

To improve the surface properties of magnesium alloy, a lining process using shot peening was carried out. The lining of magnesium alloy with metals such as titanium and nickel is useful in heightening the corrosion and wear properties for the components. In the shot peening experiment, the foil set on the magnesium workpiece is pelted with many shots at a high velocity. The foil is bonded to the surface of the workpiece due to plastic deformation induced by the collision of the shots. A pure aluminum foil is inserted between the hard foil and magnesium workpiece to assist the bonding. To heighten the bondability, the foil and workpiece are heated and the flow stresses of the metals are reduced. In this experiment, a centrifugal shot peening machine with an electrical heater was employed. The workpieces were commercially magnesium alloys AZ31B and AZ91D, and the foils were commercially pure aluminum, pure titanium and pure nickel. The effects of collision speed and ...

2003-07-01

246

In-situ focused ion beam (FIB) microscopy at high temperature  

International Nuclear Information System (INIS)

Materials Scientists need information on the kinetics of the microstructural evolution processes that determine the finished microstructure, and hence the properties, of any material. E.g. recrystallisation, grain growth and phase changes. Such kinetic information requires reliable discrimination of differently oriented crystallites and/or different crystal phases coupled with useful spatial resolution and temporal resolution (i.e. high frame rates). These imaging results must be realised from a hot and changing specimen, in an instrument that is compatible with that hot specimen and with a practical specimen heater. Focused Ion Beams (FIB) offer strong contrast between crystallites and phases, and hence offer the ability to discriminate between these features even while imaging at fast frame rates, however their compatibility with hot specimens was unproven. Here we report results from a novel combination of FIB with an in-situ heating stage, to produce in-situ, ...

2008-08-01

247

Flock-like painting for interior plastic parts. Naisoyo shokumocho toso no kaihatsu  

Energy Technology Data Exchange (ETDEWEB)

Lower cost painting flock-like in appearance and touch feeling was developed as a new surface softening method for automobile interior plastic molded parts. The base coat with the same color as piles mixed into a top coat was first painted on the surface of a plastic molded part after cleaning, and after the top coat with less pitch mixed with piles was painted on the wet base coat and dried by a heater, excess piles were removed with suction and air blowing to produce flock-like appearance. Nylon 66 of 0.4mm in length was used as piles, and mixed into the top coat by 8.0wt% in content. This painting method was applicable to even such parts as one with a complex configuration, and one impossible to set piles on it by conventional methods because of poor durability. As a certain amount of piles with different colors were mixed into the top coat, sprinkly colored appearance, unattainable by conventional methods, could be also produced. 1 ref., 13 figs., 1 tab.

1990-04-25

248

Fire detection for conveyor-belt entries. Rept. of Investigations/1991  

Energy Technology Data Exchange (ETDEWEB)

The report details the results of a series of large-scale experiments where small coal fires were used to ignite conveyor belting at air velocities ranging from 0.76 m/s to 6.1 m/s. In the tests, electrical strip heaters imbedded within a pile of coal were used to heat the coal to a point of flaming ignition. The flaming coal subsequently ignited conveyor belting located approximately 5 to 10 cm above the coal pile. During the tests, temperature, CO, and smoke levels were continuously measured in order to determine both alarm time and level as the fire intensity progressed through the stages of smoldering coal, flame coal, and flaming coal plus flaming belt. Analysis of the data leads to certain conditions of air velocity and sensor alarm levels that are required for early detection of conveyor belt entry fires. Two nomographs are presented which define sensor alarm levels and sensor spacings as a function of belt entry cross-sectional area and belt entry air ...

1991-01-01

249

Electromagnetic radiation unmasked  

International Nuclear Information System (INIS)

This article describes the nature of the electromagnetic waves, what they are and how do they affect us. Current concern is focused on exposure to low level power-frequency magnetic fields like microwave radiation from mobile phones and leaking microwave ovens; high power radiation from defence and airport radars; fields close to high voltage transmission lines; radio frequency fields from industrial welders and heaters and DC magnetic fields in aluminium smelters. These fields with frequency less than 300 GHz do not carry sufficient energy to break chemical bonds and it is assumed that they cannot damage cell DNA. The amount of radiation absorbed by a human exposed to far field electromagnetic radiation (EMR) depends on the orientation and size of the person. In the 30-300 MHz range it is possible to excite resonance in the whole or partial body such as the head. It is emphasised that since there are some evidence that electromagnetic fields do harm, a policy of ...

1996-01-01

250

Development status of a small, direct-injection diesel engine at Isuzu  

Energy Technology Data Exchange (ETDEWEB)

Development status of small direct injection diesel engine at Isuzu Motors Ltd. is reviewed. There is much difficulty in combustion optimization of small DI engines, due to small combustion chamber volume, large surface to volume ratio, wide engine speed range and so on. Novel ideas in the area of injection system, combustion chamber and induction swirl were tried to solve these problems and their effects are presented here. Our prototype DI engines which adopted some of these ideas has turned out to have better fuel economy by about 15 percent, 2 - 3 dB(A) higher noise level than IDI and almost the same power output performance as IDI. As to exhaust emissions, they have a possibility to conform to '86 California emission standards, in inertia weight classes up to 2625 LBS. The remaining problem areas are noise emission, durability of injection pump and cabin heater performance. These problems must be solved by further innovation, before DI engines will be ...

1985-01-01

251

Development of a high-performance, coal-fired power generating system with a pyrolysis gas and char-fired high-temperature furnace  

International Nuclear Information System (INIS)

A high-performance power system (HIPPS) is being developed. This system is a coal-fired, combined-cycle plant that will have an efficiency of at least 47 percent, based on the higher heating value of the fuel. The original emissions goal of the project was for NOx and SOx to each be below 0.15 lb/MMBtu. In the Phase 2 RFP this emissions goal was reduced to 0.06 lb/MMBtu. The ultimate goal of HIPPS is to have an all-coal-fueled system, but initial versions of the system are allowed up to 35 percent heat input from natural gas. Foster Wheeler Development Corporation is currently leading a team effort with AlliedSignal, Bechtel, Foster Wheeler Energy Corporation, Research-Cottrell, TRW and Westinghouse. Previous work on the project was also done by General Electric. The HIPPS plant will use a high-Temperature Advanced Furnace (HITAF) to achieve combined-cycle operation with coal as the primary fuel. The HITAF is an atmospheric-pressure, pulverized-fuel-fired boiler/air ...

1995-07-12

252

Data report of BWR post-CHF tests. Transient core thermal-hydraulic test program. Contract research  

Energy Technology Data Exchange (ETDEWEB)

JAERI has been performing transient core thermal-hydraulic test program. In the program, authors performed BWR/ABWR DBE simulation tests with a test facility, which can simulate BWR/ABWR transients. The test facility has a 4 x 4 bundle core simulator with 15-rod heaters and one non-heated rod. Through the tests, authors quantified the thermal safety margin for core cooling. In order to quantify the thermal safety margin, authors collected experimental data on post-CHF. The data are essential for the evaluation of clad temperature transient when core heat-up occurs during DBEs. In comparison with previous post-CHF tests, present experiments were performed in much wider experimental condition, covering high clad temperature, low to high pressure and low to high mass flux. Further, data at wider elevation (lower to higher elevation of core) were obtained in the present experiments, which make possible to discuss the effect of axial position on thermal-hydraulics, ...

2001-03-01

253

Analyses of mixed-hydrocarbon binary thermodynamic cycles for moderate-temperature geothermal resources  

Energy Technology Data Exchange (ETDEWEB)

A number of binary geothermal cycles utilizing mixed hydrocarbon working fluids were analyzed with the overall objective of finding a working fluid which can produce low-cost electrical energy using a moderately-low temperature geothermal resource. Both boiling and supercritical shell-and-tube cycles were considered. The performance of a dual-boiling isobutane cycle supplied by a 280/sup 0/F hydrothermal resource (corresponding to the 5 MW pilot plant at the Raft River site in Idaho) was selected as a reference. To investigate the effect of resource temperature on the choice of working fluid, several analyses were conducted for a 360/sup 0/F hydrothermal resource, which is representative of the Heber resource in California. The hydrocarbon working fluids analyzed included methane, ethane, propane, isobutane, isopentane, hexane, heptane, and mixtures of those pure hydrocarbons. For comparison, two fluorocarbon refrigerants were also analyzed. These fluorocarbons, R-115 and R-22, were ...

1981-02-01

254

An investigation into flow regimes for two-phase helium flow  

Energy Technology Data Exchange (ETDEWEB)

The Tevatron accelerator at Fermilab incorporates long two-phase helium passages. During magnet design, the generalized flow map of Baker was used to predict homogeneous flow. Longer than expected magnet time constants led to this investigation. The importance of predicting the flow regime has been amplified with the advent of non-horizontal accelerator designs. A test setup was constructed at Fermilab to investigate two-phase helium flow regimes for conditions practical in accelerator designs. The setup consisted of a standard Tevatron satellite refrigerator, subcooling dewar, heater, 35 m long transfer line, and a specialized end box. A knife blade on the midplane of the transfer line diverted the flow from the upper and lower halves of the pipe to separate vessels in the end box. The amount of liquid above and below the plane was measured at various total mass flow rates and liquid percentages. The results show that stratified flow occurs at much higher liquid ...

1987-10-01

255

Air conditioner for radioactive material handling facility  

Energy Technology Data Exchange (ETDEWEB)

An air conditioner intakes open-air from an open-air intake port to remove sands and sea salt particles by air filters. Then, natural and artificial radioactive particles of less than 1 {mu}m are removed by high performance particulate filters. After controlling the temperature by an air heater or an air cooler, air is sent to each of chambers in a facility under pressure elevation by a blower. In this case, glass fibers are used as the filter material for the high performance particulate filter, which has a performance of more than 99.97% for the particles of 0.3 {mu}m grain size. Since this can sufficiently remove the natural radioactive materials intruded from the outside, a detection limit value in each of the chambers of the facility can be set 10{sup -13} to 10{sup -14} {mu}ci/cm{sup 3} in respect of radiation control. Accordingly, radiation control can be conducted smoothly and appropriately. (I.N.).

1991-04-26

256

A new method of heat transfer augmentation by means of foreign gas jet impingement in liquid bath  

International Nuclear Information System (INIS)

The authors discuss a two-phase two-component experimental system developed to study enhancement of heat transfer from a vertical chip size heater to surrounding liquid (Freon 113 or Ethanol) due to air jet impingement. Heat transfer coefficient was measured as function of jet velocity, heat flux and the distance between exit of jet tube and heated surface. The injector was placed very close to the hot surface. It was found that the heat transfer was notably enhanced with foreign gas impingement, especially in the cases of small temperature differences between wall and coolant. In fact for higher jet velocities the heat transfer coefficients tended to infinite while the temperature differences between wall and coolant were zero. The heat transfer coefficients decreased with the increasing of heat flux. High-speed camera was used to study the behaviour of the gas bubbles which play very important role in the heat transfer process. A physical model of simultaneous ...

1985-10-01

257

Water chemistry and corrosion in water-steam circuits of nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

The water and steam circuits of steam generators in pressurized-water nuclear power plants are described together with the mechanism of denting, and the corrosion of spacer plates that leads to cracks in tubes by constriction. The different chemical specifications applicable to the water of the secondary circuit of the generators in normal operation and on first commissioning are listed. The results obtained and the measurements of chemical values taken in operation on the water in the secondary circuits of steam generators at Fessenheim and Bugey are presented.

1981-05-01

258

Water chemistry and corrosion in water-steam circuits of nuclear power plants  

International Nuclear Information System (INIS)

The water and steam circuits of steam generators in pressurized-water nuclear power plants are described together with the mechanism of denting, and the corrosion of spacer plates that leads to cracks in tubes by constriction. The different chemical specifications applicable to the water of the secondary circuit of the generators in normal operation and on first commissioning are listed. The results obtained and the measurements of chemical values taken in operation on the water in the secondary circuits of steam generators at Fessenheim and Bugey are presented.

259

Water resources data for Texas, water year 1993. Volume 3. Colorado River basin, Lavaca River basin, Guadalupe River basin, Nueces River basin, Rio Grande basin, and intervening coastal basins. Water-data report (Annual), 1 October 1992-30 September 1993  

Energy Technology Data Exchange (ETDEWEB)

Water-resources data for the 1993 water year for Texas are presented in four volumes, and consist of records of stage, discharge, and water quality of streams and canals; and stage, contents, and water quality of lakes and reservoirs; and water levels and water quality of ground-water wells. Volume 3 contains records for water discharge at 134 gaging stations; stage only at 1 gaging stations; stage and contents at 13 lakes and reservoirs; water quality at 81 gaging stations; and data for 30 partial-record and 4 flood-hydrograph partial-record stations. Also included are lists of discontinued surface-water discharge or stage-only stations and discontinued surface-water-quality stations; crest-stage and flood-hydrograph partial-record stations, reconnaissance ...

1994-03-01

260

Interaction of water with epoxy.  

Energy Technology Data Exchange (ETDEWEB)

The chemistries of reactants, plasticizers, solvents and additives in an epoxy paint are discussed. Polyamide additives may play an important role in the absorption of molecular iodine by epoxy paints. It is recommended that the unsaturation of the polyamide additive in the epoxy cure be determined. Experimental studies of water absorption by epoxy resins are discussed. These studies show that absorption can disrupt hydrogen bonds among segments of the polymers and cause swelling of the polymer. The water absorption increases the diffusion coefficient of water within the polymer. Permanent damage to the polymer can result if water causes hydrolysis of ether linkages. Water desorption studies are recommended to ascertain how water absorption affects epoxy paint.

2009-07-01

261

European Commission - Environment  

Wastenet

...Species - see CITES Trade of Dangerous Chemicals Transport and Environment U Urban Environment Use of natural resources V Volatile Organic Compounds W Waste Landfills Waste electrical and electronic equipment - see WEEE Waste incineration Waste legislation - reporting Waste management planning Waste oils Waste shipments Waste water - see Urban waste water Water Bathing Water Drinking water Floods Marine environment Urban waste water Water Framework Directive WEEE - Waste Electric and Electronic Equipment Wildlife ...

262

Video and seismic observations of Strombolian eruptions at Erebus volcano, Antarctica  

British Library Electronic Table of Contents (United Kingdom)

Between 1986 and 1990 the eruptive activity of Erebus volcano was monitored by a video camera with on-screen time code and recorded on video tape. Corresponding seismic and acoustic signals were recorded from a network of 6 geophones and 2 infrasonic microphones. Two hundred Strombolian explosions and three lava flows which were erupted from 7 vents were captured on video. In December 1986 the Strombolian eruptions ejected bombs and ash. In November 1987 large bubble-bursting Strombolian eruptions were observed. The bubbles burst when the bubble walls thinned to ?20?cm. Explosions with bomb flight-times up to 14.5?s were accompanied by seismic signals with our local size estimate, ?unified magnitudes?? (mu), up to 2.3. Explosions in pools of lava formed by flows in the Inner Crater were co...

2008-01-01

263

Thermal-hydraulic performance of the GETR emergency cooling system: experimental and analytical considerations  

International Nuclear Information System (INIS)

The General Electric Test Reactor emergency cooling system performance was tested by intentionally scramming the reactor and then terminating the power to the primary pump. Certain transient thermal-hydraulic data were obtained preceding and during the established natural convection cooling loop composed of the upward flow through the core and the downward flow through the pool. An analysis was performed to permit the data to be extrapolated to obtain distributed fuel element flow rates and bulk temperature rises during the established cooling loop. The earliest time for the quasi-steady natural cooling loop to develop is about 2.5 min following scram. The cladding hot-spot temperature does not exceed the local saturation temperature after quasi-steady flow is established. Data are presented to assist in the modeling of the GETR natural convection loop. Semi-empirical relationships for friction factor and Nusselt number are also presented.

264

The mechanisms of ethene and propene formation from methanol over high silica H-ZSM-5 and H-beta  

British Library Electronic Table of Contents (United Kingdom)

Selectivity control is a key issue in the zeolite facilitated conversion of methanol to hydrocarbons. This work addresses: (a) How the zeolite topology (MFI versus BEA) determines the type of intermediate participating in the catalytic cycle thereby controlling the ethene/propene product selectivity in the methanol to alkenes reaction, and (b) to what extent light alkene formation occurs via aromatic and alkene reaction intermediates for H-ZSM-5. Three catalyst samples have been studied in experiments relying on isotopic labeling. For H-beta, penta- and hexamethylbenzene are involved in an aromatics based hydrocarbon pool type mechanism leading predominantly to propene and the higher alkenes (a very low yield of ethene is observed), whereas for H-ZSM-5, the lower methylbenzenes are the aro...

2009-01-01

265

Stability and disturbance of large dc superconducting magnets  

Energy Technology Data Exchange (ETDEWEB)

This paper addresses the stability aspects of several successful dc superconducting magnets such as large bubble chamber magnets, and magnets for the Mirror Fusion Test Facility and MHD Research Facility. Specifically, it will cover Argonne National Laboratory 12-Foot Bubble Chamber magnets, the 15-foot Bubble Chamber magnets at Fermi National Laboratory, the MFTF-B Magnet System at Lawrence Livermore National Laboratory, the U-25B Bypass MHD Magnet, and the CFFF Superconducting MHD magnet built by Argonne National Laboratory. All of these magnets are cooled in pool-boiling mode. Magnet design is briefly reviewed. Discussed in detail are the adopted stability critera, analyses of stability and disturbance, stability simulation, and the final results of magnet performance and the observed coil disturbances.

1981-11-11

266

Selenium fractions in selenate-fertilized field soils of Finland  

British Library Electronic Table of Contents (United Kingdom)

Depending on the soil environment, selenium (Se) can exist as several species differing greatly in bioavailability. Characterization of soil Se reserves is thus necessary in assessing the nutritional supply of this essential element. In low-Se areas, Se fertilization is an option for securing adequate Se nutrition. Fertilization is, however, challenged by the unknown fate of the residual Se. In this study, we aimed to clarify the Se status of selenate-fertilized field soils by fractionating soil Se into five pools: salt-soluble (KCl), adsorbed (KH2PO4/K2HPO4), organically associated (NaOH), elemental (Na2SO3) and recalcitrant Se (NaOCl). Changes induced in these fractions by repeated application of low selenate doses were examined by comparing samples collected from the same locations in 1...

2011-01-01

267

Pathogenic microorganisms carried by migratory birds passing through the territory of the island of Ustica, Sicily (Italy)  

British Library Electronic Table of Contents (United Kingdom)

Several studies have shown that migratory birds play an important role in the ecology, circulation and dissemination of pathogenic organisms. In October 2006, a health status evaluation was performed on a large population of migratory birds passing through the territory of Ustica (Italy), an island located on the migration route of many species of birds to Africa, and various laboratory tests were conducted. In total, 218 faecal swabs and the internal organs of 21 subjects found dead in nets were collected for bacteriological and virological examination, including avian influenza and Newcastle disease. In addition, 19 pooled fresh faecal samples were collected for mycological examination. The bacteriological analysis produced 183 strains belonging to 28 different species of the Enterobacte...

2011-01-01

268

Natural convection cooling of liquid metal systems  

International Nuclear Information System (INIS)

The recognition that natural convection offers the prospect of an important inherent safety feature for liquid metal cooled reactor systems has provided the impetus for a world-wide research effort over the past decade. Whilst this research has been based on experiment, both plant experiments and out-of-pile experiments, the enormous advances in the development of computing power in recent years have enabled complementary programmes of mathematical modelling through numerical simulation of the transport equations in three spatial dimensions. These not only offer considerable promise for the designer in projecting the behaviour from experiments and prototype plant to full scale plant, they have also proved to be of considerable value in helping us to interpret and understand the results of the experiments themselves. This paper attempts to review the progress made with the emphasis on decay heat removal by natural convection in the pool-type system. (author).

269

Molecular analysis of polymerase gamma gene and mitochondrial polymorphism in fertile and subfertile men  

British Library Electronic Table of Contents (United Kingdom)

Summary CAG trinucleotide repeat length in the nuclear polymerase gamma gene (POLg) has been shown to be associated with men with reduced fertility. The present study investigated the frequency of CAG repeat length genotypes and three exonuclease motifs of the POLg in relation to the frequency of mitochondrial nucleotide substitutions. DNA from semen samples of 93 normozoospermic men and 192 non-normozoospermic men was isolated and the specific regions of the genes were amplified by polymerase chain reactions (PCR) and sequenced to identify mutations. The genotypic frequencies of pooled POLg CAG repeat lengths, =10/!=10 heterozygotes and !=10/!=10 homozygotes, were significantly different between normozoospermic and non-normozoospermic men (p p POLg genotype. Of the 17 men with non-synonym...

2006-01-01

270

Modeling dispersion and deposition of smoke generated from chemical fires  

British Library Electronic Table of Contents (United Kingdom)

Abstract Smoke is a mixture of toxic gases and suspended particulate matter of solids and liquids that evolves from a fire of flammable materials. This article presents real-time consequence modeling to track the concentration of individual species in smoke as well as its soot deposition. In the modeling process presented, the burning rate or vapor mass is fed into a combustion model in which the combustion of products has been identified and quantified along with the temperature of the fire. The output of the combustion model is the smoke that will be dispersed into the ambient. The fire geometry, which depends on the type of fire (e.g., pool or flare), is identified. A dispersion model with the capability of determining particulate deposition is then used for tracking the smoke plume. Th...

2011-01-01

271

Mitochondria-localized NAD biosynthesis by nicotinamide mononucleotide adenylyltransferase in Jerusalem artichoke (Helianthus tuberosus L.) heterotrophic tissues  

British Library Electronic Table of Contents (United Kingdom)

Current studies in plants suggest that the content of the coenzyme NAD is variable and potentially important in determining cell fate. In cases that implicate NAD consumption, re-synthesis must occur to maintain dinucleotide pools. Despite information on the pathways involved in NAD synthesis in plants, the existence of a mitochondrial nicotinamide mononucleotide adenylyltransferase (NMNAT) activity which catalyses NAD synthesis from nicotinamide mononucleotide (NMN) and ATP has not been reported. To verify the latter assumed pathway, experiments with purified and bioenergetically active mitochondria prepared from tubers of Jerusalem artichoke (Helianthus tuberosus L.) were performed. To determine whether NAD biosynthesis might occur, NMN was added to Jerusalem artichoke mitochondria (JAM)...

2011-01-01

272

Kestose:sucrose fructosyl transfer - a potential problem in the investigation of fructan and sucrose metabolism  

Energy Technology Data Exchange (ETDEWEB)

Wheat leaves can be induced by excision to produce fructans. Fructose residues of newly made oligofructans in leaves labeled in vivo with {sup 14}CO{sub 2} are not equally labeled. We report here on a fructosyl transferase activity in wheat leaves catalyzing the reaction: G{sup *}-F{sup *} + G-F-F = G{sup *}-F{sup *}-F + G-F. This activity, described previously in J. artichoke was attributed to fructan:fructan fructosyl transferase (FFT). The rate of this reaction in vitro is much higher than that of net kestose synthesis by SST. Hence, appearance of labeled 1-kestose from sucrose may not be an accurate measure of SST, but a curious reshuffling of hexoses between pools of 1-kestose and sucrose.

1990-05-01

273

Isolation and molecular identification of small ruminant mycoplasmas in Jordan  

British Library Electronic Table of Contents (United Kingdom)

Mycoplasma infections of small ruminants are known to exist in the Mediterranean region, Asia, Africa and cause significant economic impacts but little is known of the Mycoplasma spp. in sheep and goats in the Middle East. During the period of 2002-2003, 104 flocks of local sheep and goats (17 sheep, 27 goat and 60 mixed flocks) were surveyed for the occurrence of mycoplasma infections in Northern Jordan. The clinical signs seen in the studied flocks were, to varying degrees, mastitis in sheep and goats, arthritis, mainly in kids, and pneumonia in both sheep and goats of most age groups. Small ruminant farms were sampled and pooled milk samples and nasal swabs were collected for culture and isolation of mycoplasma. Mycoplasmas were isolated from 17 (26%) of the 62 milk samples and 12 (3.9%...

2006-01-01

274

FFTF reactor characterization program  

International Nuclear Information System (INIS)

Preparations are under way for the initial startup and testing of the Fast Flux Test Facility (FFTF). The FFTF Reactor Characterization Program is that part of the startup test plan that deals with the determination of the neutron, gamma ray and thermal hydraulic characteristics of the reactor. This program encompasses measurements and calculations of: neutron spectra, flux and fluence; gamma-ray spectra, dose and heating; fission rate distributions; capture rate distributions; other reaction rates of interest; fission product yields; and thermal hydraulic data. Measurements of these parameters will be made in the reactor core and reflectors, will extend vertically downward to the vicinity of the core support structure and upward to the top of the sodium pool, and will extend radially outward to include in-vessel fuel storage locations and the cavity between the reactor vessel and the concrete wall.

275

Environmental education work force pipeline strategic plan  

Energy Technology Data Exchange (ETDEWEB)

This document describes an educational program designed to provide a pool of highly qualified administrative, technical, and managerial graduates that are familiar with the Hanford Site and business operations. The program is designed to provide work experience and mentoring to a culturally diverse student base which enhances affirmative employment goals. Short-term and long-term objectives of the program are outlined in the report, and current objectives are discussed in more detail. Goals to be completed by the year 2003 are aimed at defining the criteria necessary to establish partnerships between schools, community organizations, and human resources departments. Actions to be implemented includes providing instructors and equipment, enhancing skills of local teachers, and establishing collaboration with human resources organizations. Long-term goals of the program are to ensure a constant supply of qualified, trained workers to support industry missions. 6 ...

1992-11-01

276

Energy and reserve dispatch in a multi-zone electricity market  

Energy Technology Data Exchange (ETDEWEB)

Competitive bidding for ancillary services (A/S), in addition to bidding for energy, is increasingly recognized as an important part of electricity markets. In this paper, an LP-based approach is presented for solving the multi-product (i.e. energy and A/S products), multi-zone/area physical market dispatch problem. The approach can explicitly represent various constraints, such as reserve requirement constraints, network security limits, and sharing of constrained resource capacity (e.g. maximum unit generation) between energy and reserve. The joint dispatch method, which dispatches energy and reserve market concurrently, is extended to allow inter-zonal reserve trading in multi-zone competitive pool. Numerical examples are included to demonstrate the salient characteristics of the joint dispatch solution.

1999-08-01

277

Design and field trial application of foam in production wells to improve conformance  

Energy Technology Data Exchange (ETDEWEB)

The experimental foam treatments conducted on two production wells, each in a different miscible flood pool, were described, including aspects of the laboratory work, numerical coning simulation, well selection process and foam placement strategy. One of the wells was injected with a foam-forming surfactant, as well as with a surface-generated preformed foam. Neither of these treatments had any effect on the performance of this well. In the other well, preformed foam treatment was successful in reducing gas-oil ratio, resulting in improved oil production over a 14-month period. Future foam injection projects are being planned, based on the experiences gained in this field experiment. 13 refs., 21 figs.

1997-02-01

278

Coalification by clay-catalyzed oligomerization of plant monomers. [Methyleugenol  

Science.gov (United States)

During this report period, we have obtained a model of montmorillonite clay, and this model has been of great assistance in visualizing how the chemistry of substrate molecules might be altered as it occurs on the surface of the clay. A stereochemical representation of this montmorillonite model is shown. Of particular significance, this model indicates that hydroxyl groups are located in the center of each siloxane ring on the surface of the montmorillonite clay. These hydroxyl groups might serve to bond substrate molecules to the surface of the clay. The next step in our systematic examination of the radical cation-initiated dimerization of plant monomers from the C{sub 6}-C{sub 3} pool of shikimic acid metabolites was to study the dimerization of cinnamic acid and its derivatives. In the next block of research, we examined the reaction of montmorillonite clay (K-10) with methyleugenol. 2 refs.

1990-01-01

279

Classified Stable Matching  

CERN Document Server

We introduce the {\\sc classified stable matching} problem, a problem motivated by academic hiring. Suppose that a number of institutes are hiring faculty members from a pool of applicants. Both institutes and applicants have preferences over the other side. An institute classifies the applicants based on their research areas (or any other criterion), and, for each class, it sets a lower bound and an upper bound on the number of applicants it would hire in that class. The objective is to find a stable matching from which no group of participants has reason to deviate. Moreover, the matching should respect the upper/lower bounds of the classes. In the first part of the paper, we study classified stable matching problems whose classifications belong to a fixed set of ``order types.'' We show that if the set consists entirely of downward forests, there is a polynomial-time algorithm; otherwise, it is NP-complete to decide the existence of a stable matching. In the ...

2009-01-01

280

Assessment, development and coordination of technology base studies in enhanced heat transfer. Quarterly progress report No. 7, March 1, 1983-May 31, 1983  

Energy Technology Data Exchange (ETDEWEB)

The major goal of this continuation project is to advance the utilization of heat transfer enhancement techniques in commercial heat exchange equipment. Thirteen heat transfer enhancement techniques have been identified as having potential for improving heat transfer coefficients in full-scale industrial equipment. The following tasks are part of this project, which was originally planned for three years: (1) expansion of technology information base; (2) evaluation of performance of enhanced surfaces and inserts; (3) correlation of data for spirally fluted surfaces; (4) study of structured surfaces in pool boiling; and (5) study of structured surface in spray film evaporation.

1983-08-01

281

A Multi-Layered Image Cache for Scientific Visualization  

Energy Technology Data Exchange (ETDEWEB)

We introduce a multi-layered image cache system that is designed to work with a pool of rendering engines to facilitate an interactive, frameless, asynchronous rendering environment. Our system decouples the rendering from the display of imagery. Therefore, it decouples render frequency and resolution from display frequency and resolution, and allows asynchronous transmission of imagery instead of the compute/send cycle of standard parallel systems. It also allows local, incremental refinement of imagery without requiring all imagery to be re-rendered. Images are placed in fixed position in camera (vs. world) space to eliminate occlusion artifacts. Display quality is improved by increasing the number of images. Interactivity is improved by decreasing the number of images.

2003-06-26

282

Phosphorus and nitrogen in the eutrophication of waters. Fosfori ja typpi vesien rehevoeittaejinae - vaikutusten arviointi  

Energy Technology Data Exchange (ETDEWEB)

This report is a summary of the contribution of nitrogen and phosphorus in the eutrophication process of inland and coastal waters. Special attention was paid to the mechanisms of these nutrients in regulating biological processes and to the methods available in estimating their effects in the eutrophication of water bodies. The report includes five chapters which are entitled: Introduction, which is a general background to the subject with special attention to the requirements of the Finnish Water Act. Phosphorus and nitrogen as factors regulating biological processes. The topics included are: definition of eutrophication, forms of phosphorus and nitrogen and their sources to inland and coastal waters, effects of these nutrients as growth factors of phytoplankton and macrophytes and consequences of eutrophication. Estimation of the effects of phosphorus and nitrogen. The topics discussed from the point ...

1992-01-01

283

Formulation and make-up of simulate dilute water, low ionic content aqueous solution  

Energy Technology Data Exchange (ETDEWEB)

This procedure describes the formulation and make-up of Simulated Dilute Water (SOW), a low-ionic-content water to be used for Activity E-20-50, Long-Term Corrosion Studies. This water has an ionic content which is nominally a factor of ten higher than that of representative waters at or near Yucca Mountain. Representative waters were chosen as J-13 well water [Harrar, 1990] and perched water at Yucca Mountain [Glassley, 1996]. J-13 well water is obtained from ground water that is in contact with the Topopah Spring tuff, which is the repository horizon rock. The perched water is located in the Topopah Spring tuff, but below the repository horizon and above the water table. A nominal times ten higher ionic content was chosen to simulate the effect of ionic ...

1997-04-04

284

On-farm water management in saline groundwater area under scarce canal water supply condition in the Northwest India  

British Library Electronic Table of Contents (United Kingdom)

The study investigates the possibility of enhancing crop water productivity in the parts of Northwest India where groundwater quality is marginal and canal water supply is severely scarce. Soil, Water, Atmosphere and Plant (SWAP) model was calibrated and validated in three farmers' fields with varying canal water availability and groundwater quality in the Kaithal Irrigation Circle of the Bhakra Canal system, Haryana. On the basis of predicted and observed soil water content, pressure heads, salt concentration at 2 week intervals and crop yields, the model was found suitable for use in the region. A few nomographs were prepared to provide a graphical method to predict the effect of different combinations of water quality and depth of water application on crop yield and soil salinity and to...

2008-01-01

285

Major roles of water chemistry for safe and reliable nuclear power plant operation. Research committee on water chemistry standard  

International Nuclear Information System (INIS)

The research committee of the Atomic Energy Society of Japan on water chemistry standard aims at establishing the private standard of water chemistry of nuclear power plants. The committee gathers up 'BWR water chemistry management manual', 'PWR primary system water chemistry management manual' and 'PWR water chemical analysis standard method', and furthermore aims at the standardization of those in future. Looking back on the committee's activities for the past four years, latest results of research of water chemistry mainly contributing to safe and reliable nuclear power plants were described with the future perspective of water chemistry and a demanded break-through. (T.T.)

2007-05-01

286

Laser-fluorescence determination of trace uranium in hot spring water, geothermal water and tap water in Xi'an Lishan region  

International Nuclear Information System (INIS)

Using the Laser-Fluorescence technique, an investigation was made, adopting the standard mix method, on trace uranium concentrations in hot spring water and geothermal water from Lishan region, and in tap water from some major cities in Shanxi province. Totally 40 samples from 27 sites were investigated. Measurement showed that the tap water contains around 10"-"6 g/L of uranium, whose concentrations in both hot spring water and geothermal water are 10"-"5 g/L. Most of samples are at normal radioactive background level, some higher contents were determined in a few samples

2002-03-01

287

Corrosion behavior of iron and nickel base alloys in high temperature and pressure water  

International Nuclear Information System (INIS)

In equipment industries, the equipments handling industrial water and pure water are numerous. In power generation including nuclear power generation, water serves as a working medium. Review is made on the experiences in the corrosion of iron and nickel base alloys in high temperature, high pressure water and the results of researches derived from them. Under high temperature and high pressure, carbon steel, low alloy steel, stainless steel and high nickel alloy cause corrosion even in pure water. But in the case of serious corrosion, chlorine, oxygen, alkali and others in water take part. The following matters are described: corrosion by steam; stress corrosion cracking in pure water; corrosion by impurities in high temperature, high pressure pure water, i.e. chlorine ions, dissolved oxygen, and alkali; corrosion under ...

288

AquaMagna Water Conditioner and Descaler  

Wastenet

...AquaMagna Water Conditioner and Descaler OCETA Environmental Technology & Business Profiles AQUAMAGNA WATER CONDITIONER AND DESCALER CAT. #03-018 CONTACT: Magna-Tek ...removal high-strength ceramic magnet no energy input The AquaMagna Water Conditioner and Descaler is a non-chemical method of water treatment. The technology uses ... Figure 1: The AquaMagna Water Conditioner and Descaler PROCESS/ PRODUCT APPLICATION: hard water domestic water process water reverse osmosis heat exchangers cooling ... For once-through or recirculating heating or cooling equipment, the AquaMagna descaler improves thermal efficiencies and reduces downtime. Figure 2 illustrates a cross-section ...

289

Water | Editorial Board  

Wastenet

...Tota-MaharajE-Mail: Interests: water and wastewater treatment, environmental engineering and sustainable systems; sustainable water management; sustainable urban drainage systems (SUDS); combined renewable energy applications with reverse osmosis desalination; microbial fuel cells for bioenergy production and treatment of urban wastewater; solar photocatalytic treatment and disinfection of water/wastewater Dr. Simon Toze CSIRO Land and Water, Queensland Bioscience Precinct - St Lucia, 306 Carmody Road, St Lucia QLD 4067,...

290

Changes in water dependence of Russian economy  

British Library Electronic Table of Contents (United Kingdom)

Indicators of source water use in different economic branches, water consumption in recycling and recycling-successive water supply in 1980?2006 are analyzed. Trends were identified in variations in specific water consumption in industry, agriculture, and municipal economy. Territorial differentiation of wetness indicators of regional product over federal districts and constituent territories of the RF is shown. Wetness values of gross domestic product in different economies are compared.

2010-01-01

291

USGS Arkansas Water Science Center  

Science.gov (United States)

number Fax (501) 228-3600 (501) 228-3601 Surface Water Data Information Requests Bill Baldwin (501) 228-3602 Surface Water General Information Jaysson Funkhouser (501) 228-3663...

2011-09-23

292

The BEACHES Study: health effects and exposures from non-point source microbial contaminants in subtropical recreational marine waters  

UK PubMed Central (United Kingdom)

Background Microbial water-quality indicators, in high concentrations in sewage, are used to determine whether water is safe for recreational purposes. Recently, the use of these indicators...Full Text Available

2010-10-01

293

Study on the separation characteristics of tritiated water vapor adsorption.  

Science.gov (United States)

In order to reduce the air concentration of (sup 3)H in the reactor buiIding of Wolsung Heavy Water Reactor, a computer code for estimation of adsorption behavior was programmed based on an equation derived for analysis of water vapor adsorption, and a ba...

1991-01-01

294

Rational protection of the quality of coastal waters by means of integrated, real-time management of the water environment; Proteccion racional de la calidad de las aguas costeras mediante la gestion integrada y en tiempo real del medio hidrico  

Energy Technology Data Exchange (ETDEWEB)

Before the implementation Water Framework directive, it was usual to forget that a good environment protection of the receiving waters needs a correct and coordinated operation of the subsystems of the water cycle, specially sewerage system, WWTP and receiving waters. This explains that most of the countries have focused their efforts in the treatment of dry weather flows forgetting the management of wet weather flows. Actually the idea that a sewerage system or a WWTP can not be planned or managed independently without considering the effects on the receiving waters is commonly accepted because not only each one of these systems must work correctly but also it is required a minimum impact in the receiving waters of the sewerage and WWTP overflows in dry and wet weather. All these links will affect the management strategy of the sewerage system (storm ...

2005-07-01

295

On the water-chemical regime in steam generators at NPP  

British Library Electronic Table of Contents (United Kingdom)

The effect of the water-chemical regime (WCR) on damage sustained by heating surfaces of steam generators at NPP is analyzed. It is indicated that phosphate treatment with minimal excesses of phosphates in the steamgenerator water is the most optimal method of managing the WCR regime of horizontal steam generators.

2006-01-01

296

Nodule and Leaf Nitrate Reductases and Nitrogen Fixation in Medicago sativa L. under Water Stress  

UK PubMed Central (United Kingdom)

The effect of water stress on patterns of nitrate reductase activity in the leaves and nodules and on nitrogen fixation were investigated in Medicago sativa L. plants watered 1 week...Full Text Available

1982-02-01

297

Monte Carlo modeling of 60Co HDR brachytherapy source in water and in different solid water phantom materials  

UK PubMed Central (United Kingdom)

The reference medium for brachytherapy dose measurements is water. Accuracy of dose measurements of brachytherapy sources is critically dependent on precise measurement of the source–detector...Full Text Available

2010-01-01

298

Modeling of soluble impurities distribution in the steam generator secondary water  

Energy Technology Data Exchange (ETDEWEB)

A model was developed to compute concentration of impurities in the WWER 440 steam generator (SG) secondary water along the tube bundle. Calculated values were verified by concentration values obtained from secondary water sample chemical analysis. (orig.). 2 refs.

1997-12-31

299

Measurement of the Water Potential of Stored Potato Tubers 1  

UK PubMed Central (United Kingdom)

A method of measuring the water potential of stored potato tubers (Solanum tuberosum L.) was needed to investigate the relationship of bacterial soft rot in tubers to water potential....Full Text Available

1985-11-01

300

Invasion and control of water hyacinth (Eichhornia crassipes) in China*  

UK PubMed Central (United Kingdom)

By the time of primary 21st century, water hyacinth had become a serious environmental problem in China. Water hyacinth contributes to the major part of ecological hazards from the invasion of foreign...Full Text Available

2006-08-01

301

In vivo Visualization of the Water-refilling Process in Xylem Vessels Using X-ray Micro-imaging  

UK PubMed Central (United Kingdom)

Background and AimsXylem vessels containing gases (embolized) must be refilled with water if they are to resume transport of water through the plant, so refilling is of great importance...Full Text Available

2008-03-01

302

Heat-transfer analysis of the plum brook reactor - NASA Technical ...  

Science.gov (United States)

average bulk water temper ature rise, OF bulk water temperature at elevation z, OF bulk water temperature in channels 0 and 1, O F film temperature, OF ...

303

Device for controlling water supply to nuclear reactor  

International Nuclear Information System (INIS)

Object: To smoothly control automatic water supply for realizing stable operation of a nuclear reactor by providing a flow rate limiting signal selection circuit and a preferential circuit in a water supply control device for a nuclear reactor wherein the speed of a recirculation pump may be changed in two-steps. Structure: Opening angle signals for a water supply regulating valve are controlled by a nuclear reactor water level signal, a vapor flow rate signal and a supplied water flow rate signal through an adder and an adjuster in response to a predetermined water level setting signal. When the water in the reactor is maintained at a predetermined level, a selection circuit receives a water pump condition signal for selecting one of the signals from a supplied water rate limiting signal generator ...

305

Bacterial indicators of risk of diarrhoeal disease from drinking-water in the Philippines.  

UK PubMed Central (United Kingdom)

Inadequate measures of water quality have been used in many studies of the health effects associated with water supplies in developing countries. The present 1-year epidemiological-microbiological study...Full Text Available

1991-01-01

306

TEM characterization of Al/Al{sub 2}O{sub 3} composite fabricated by reactive metal infiltration  

Energy Technology Data Exchange (ETDEWEB)

The microstructure of Al/{alpha}-Al{sub 2}0{sub 3} composites made by infiltrating Al into dense mullite preforms has been characterized using transmission electron microscopy. Observations revealed that the formation of the Al/Al{sub 2}0{sub 3} composites involves three stages. Initially, Al infiltrates into a dense mullite preform through grain boundary diffusion, and reacts with mullite at grain boundaries to form a partial reaction zone. Then, a complete reaction takes place in the reaction region between the partial reaction zone and the full reaction zone to convert the dense mullite preform to a composite of {alpha}-Al{sub 2}0{sub 3} (matrix) and an Al-Si phase (thin channels). Finally, the reduced Si from the reaction diffuses out of the Al/Al{sub 2}0{sub 3} composite through the metal channels, whereas Al from the molten Al pool is continuously drawn to the reaction region until the mullite preform is consumed or the sample is removed from the molten Al ...

1994-12-31

307

Sump Pool Flow Simulation during Fill-up Phase of LOCA Using on CFD for OPR1000 Plant  

Energy Technology Data Exchange (ETDEWEB)

During LOCA (Loss of Coolant Accident) in design bases accident (DBA), emergency core coolant supplements form a recirculation sump and cooled core and containment. When the double ended guillotine Break (DEGB) at the hot leg near steam generator, due to the jet impingement discharge flow, the debris could be potentially generated at pipe or wall nearby steam generator and be transported to the recirculation sump. Therefore, the debris, such as insulations and paint chips, could be accumulated and be clogged in the recirculation sump screen. If debris is blocked the sump strainer, the pressure drop is increased at the screen so as to increase the pressure loss of ECCS (Emergency Core Cooling System) pump NPSH (Net positive suction head). It is potentially influenced to decrease the long-term cooling capability of the recirculation sump. The recirculation sump screen clogging accident has happened in BWR of USA and Sweden. Considering the important to safety, US NRC (Nuclear Safety ...

2009-10-15

308

Sequences, geographic variations and molecular phylogeny of venom phospholipases and threefinger toxins of eastern India Bungarus fasciatus and kinetic analyses of its Pro31 phospholipases A2.  

Science.gov (United States)

Eight phospholipases A2 (PLAs) and four three-finger-toxins (3FTx) from the pooled venom of Bungarus fasciatus (Bf) were previously studied and sequenced, but their expression pattern in individual Bf venom and possible geographic variations remained to be investigated. We herein analyze the individual venom of two Bf specimens from Kolkata (designated as KBf) to address this question. Seven PLAs and five 3FTx were purified from the KBf venoms, and respective cDNAs were cloned from venom glands of one of the snakes. Comparison of their mass and N-terminal sequence revealed that all the PLAs were conserved in both KBf venoms, but that two of their 3FTx isoforms were variable. When comparing the sequences of these KBf-PLAs with those published, only one was found to be identical to that of Bf Vb-2, and the other five were 94-98% identical to those of Bf II, III, Va, VI and XI-2, respectively. Notably, the most abundant PLA isoforms of Bf and KBf venoms contain Pro31 ...

2006-12-08

309

Irradiation of Microbes from Spent Nuclear Fuel Storage Pool Environments  

Energy Technology Data Exchange (ETDEWEB)

Microbes have been isolated and identified from spent nuclear fuel storage pools at the Idaho National Engineering and Environmental Laboratory (INEEL). Included among these are Corynebacterium aquaticum, Pseudomonas putida, Comamonas acidovorans, Gluconobacter cerinus, Micrococcus diversus, Rhodococcus rhodochrous, and two strains of sulfate-reducing bacteria (SRB). We examined the sensitivity of these microbes to a variety of total exposures of radiation generated by a 6-MeV linear accelerator (LINAC). The advantage of using a LINAC is that it provides a relatively quick screen of radiation tolerance. In the first set of experiments, we exposed each of the aforementioned microbes along with four additional microbes, pseudomonas aeruginosa, Micrococcus luteus, Escherchia coli, and Deinococcus radiodurans to exposures of 5 x 10{sup 3} and 6 x 10{sup 4} rad. All microbial specimens withstood the lower exposure with little or no reduction in cell population. Upon ...

1999-09-03

310

Fragmentation of a single molten metal droplet penetrating sodium pool I copper droplet and the relationship with copper jet  

International Nuclear Information System (INIS)

The progression of hypothetical core disruptive accidents in metallic fuel fast breeder reactors is strongly affected by the fragmentation of molten metallic fuels due to the molten fuel-coolant interaction (FCI). As a basic study of FCI, the present paper focuses on the fragmentation of a single molten copper droplet with mass from 1 to 5 g, which penetrated a sodium pool at instantaneous constant interface temperatures (Ti) from 995 to 1,342degC. Intensive fragmentation of a single molten copper droplet was clearly observed even if Ti values are below the melting point (1,083degC) of copper besides the higher Ti range. The intensive fragmentation shows that the mass median diameters (Dm) of copper droplets with a fivefold difference in mass or the same mass have little difference, i.e., they are nearly the same. Under the lower Ti condition, the Dm data of droplet fragments of both the same and different masses scatter widely. It is found that the present Dm/D0 ...

2009-05-01

311

EHD enhancement of pool and in-tube boiling of alternate refrigerants. Final report, 15 January 1993--15 June 1993  

Energy Technology Data Exchange (ETDEWEB)

The Electrohydrodynamic (EHD) is an active heat transfer augmentation technique which utilizes the effect of secondary motions generated through the application of an electrostatic potential to a dielectric fluid. Net result is better momentum and heat transfer between the fluid and the heat transfer wall through destabilization of the thermal boundary layer and better mixing of the fluid adjacent to the heat transfer surface. EHD enhancement of refrigerant/refrigerant oil mixtures heat transfer using the Electrohydrodynamic (EHD) technique is the subject of a three-year experimental investigation in a project funded by the US Department of Energy, effective June 1, 1993. For the interim period between November 1992 and June 1993 when the DOE funds became available, the Air-Conditioning and Refrigeration Technology Institute (ARTI) provided partial funding for our EHD research program with the aim of accomplishing three major tasks: (1) conduct a comprehensive search of the literature ...

1993-08-01

312

Defecographic diagnosis of the puborectalis syndrome; Diagnosi mediante defecografia della sindrome del muscolo puborettale  

Energy Technology Data Exchange (ETDEWEB)

The puborectalis syndrome is a defecation disorder supported by the nonrelaxation of puborectalis sling with consequent dyschezia. They report on a series of 98 patients submitted to clinical examination, defecography, anorectal manometry, electromyography and intestinal transit time studies. The main symptoms of puborectalis syndrome in their patients were incomplete defecation (89 %) and intermittent evacuation (63 %); 28 % of patients turned to finger defecation. In all patients, defecography showed an abnormal increase in puborectalis impression on the posterior anorectal wall, reduced anorectal angle opening under straining (mean value: 113 deg) and prolonged expulsion time with barium pooling in the ampulla (mean evacuation time: 38 seconds). Such anorectal abnormalities as rectal mucosal prolapse (47 cases) and anterior rectocele (36 cases) were also associated. In 33 of 98 patients (34 % of cases), sling assessment by bidigital palpation at preliminary ...

1997-04-01

313

Defecographic diagnosis of the puborectalis syndrome  

International Nuclear Information System (INIS)

The puborectalis syndrome is a defecation disorder supported by the nonrelaxation of puborectalis sling with consequent dyschezia. They report on a series of 98 patients submitted to clinical examination, defecography, anorectal manometry, electromyography and intestinal transit time studies. The main symptoms of puborectalis syndrome in their patients were incomplete defecation (89 %) and intermittent evacuation (63 %); 28 % of patients turned to finger defecation. In all patients, defecography showed an abnormal increase in puborectalis impression on the posterior anorectal wall, reduced anorectal angle opening under straining (mean value: 113 deg) and prolonged expulsion time with barium pooling in the ampulla (mean evacuation time: 38 seconds). Such anorectal abnormalities as rectal mucosal prolapse (47 cases) and anterior rectocele (36 cases) were also associated. In 33 of 98 patients (34 % of cases), sling assessment by bidigital palpation at preliminary ...

314

Caldicellulosiruptor obsidiansis sp. nov., an anaerobic, extremely thermophilic, cellulolytic bacterium isolated from Obsidian Pool, Yellowstone National Park  

Energy Technology Data Exchange (ETDEWEB)

A novel, obligately anaerobic, extremely thermophilic, cellulolytic bacterium, designated OB47T, was isolated from Obsidian Pool, Yellowstone National Park, WY, USA. The isolate was a non-motile, non-spore forming, Gram-positive rod approximately 2 m long by 0.2 m wide and grew at temperatures between 55-85oC with the optimum at 78oC. The pH range for growth was 6.0-8.0 with values of near 7.0 being optimal. Growth on cellobiose produced the fastest specific growth rates at 0.75 hr-1. The organism also displayed fermentative growth on glucose, maltose, arabinose, fructose, starch, lactose, mannose, sucrose, galactose, xylose, arabinogalactan, Avicel, xylan, filter paper, processed cardboard, pectin, dilute acid-pretreated switchgrass and Populus. OB47T was unable to grow on mannitol, fucose, lignin, Gelrite, acetate, glycerol, ribose, sorbital, carboxymethylcellulose and casein. Yeast extract stimulated growth and thiosulfate, sulfate, nitrate, and sulfur were not ...

2010-02-01

315

Biologically effective dose in total-body irradiation and hematopoietic stem cell transplantation  

Energy Technology Data Exchange (ETDEWEB)

Background and Purpose: Total-body irradiation (TBI) is an important part of the conditioning regimen for hematopoietic stem cell transplantation (HSCT) in patients with hematologic malignancies. The results after treatment with various TBI regimes were compared, and dose-effect relationships for the endpoints relapse incidence, disease-free survival, treatment-related mortality, and overall survival were derived. The aim was to define requirements for an optimal treatment schedule with respect to leukemic cell kill and late normal-tissue morbidity. Material and Methods: A literature search was performed. Three randomized studies, four studies comparing results of two or three TBI regimens, and nine reports with results of one specific TBI regimen were identified. Biologically effective doses (BEDs) were calculated. The results of the randomized studies and the studies comparing results of two or three TBI regimens were pooled, and the pooled ...

2006-11-15

316

Biologically effective dose in total-body irradiation and hematopoietic stem cell transplantation  

International Nuclear Information System (INIS)

Background and Purpose: Total-body irradiation (TBI) is an important part of the conditioning regimen for hematopoietic stem cell transplantation (HSCT) in patients with hematologic malignancies. The results after treatment with various TBI regimes were compared, and dose-effect relationships for the endpoints relapse incidence, disease-free survival, treatment-related mortality, and overall survival were derived. The aim was to define requirements for an optimal treatment schedule with respect to leukemic cell kill and late normal-tissue morbidity. Material and Methods: A literature search was performed. Three randomized studies, four studies comparing results of two or three TBI regimens, and nine reports with results of one specific TBI regimen were identified. Biologically effective doses (BEDs) were calculated. The results of the randomized studies and the studies comparing results of two or three TBI regimens were pooled, and the pooled ...

2006-11-01

317

Assessment of generation temperatures of crude oils  

Energy Technology Data Exchange (ETDEWEB)

Biological marker maturity parameters were used to estimate the minimum HC generation temperatures of crude oils from Eastern Hungary. More than 50 oils and oil shows were analysed. Molecular- and homologous-ratios of biological marker compounds (triterpanes, steranes, mono- and triaromatic steroid hydrocarbons) were used as maturation parameters. The oils have at least five maturity stages, i.e. they have been generated under different thermal conditions. The highest reservoir temperature in each group was chosen as the best estimate of the groups' temperature just below the generation temperature, i.e. reservoirs of the group might be expected to be at shallower depths (lower temperatures) than those of the generation zone due to vertical migration into pools. For each maturation level, a threshold temperature range for genesis was inferred from reservoir temperatures; they are from 130-135{sup o}C for the least mature oils to 210-215{sup o}C for the ...

2000-07-01

318

A summary of the California Public Utilities Commission`s two competing electric utility restructuring proposals  

Energy Technology Data Exchange (ETDEWEB)

In May 1995, the California Public Utilities Commission (CPUC) released two proposals for restructuring the state`s electric power industry. The two proposals follow more than a year of testimony and public comment after the CPUC issued the ``Blue Book`` (CPUC 1994a) on April 20, 1994, which called for retail wheeling to be phased in to all customers over 5 years. The majority proposal, supported by three of the four CPUC commissioners (one seat was vacant when the proposals were released), calls for creating a central pool, or ``poolco``; setting electric prices to reflect true costs of service, or ``real-time pricing``; and allowing parties to negotiate ``contracts for differences`` between the pool price and the contract price. The minority proposal, sponsored by Commissioner Jesse Knight, calls for retail wheeling, or ``direct access,`` and for utilities to divest or spin off their generating assets. This paper presents a summary of the ...

1995-11-01

319

A sample preparation for quantitative determination of magnesium in individual lymphocytes by electron probe X-ray microanalysis.  

Science.gov (United States)

We present a sample preparation method for measuring magnesium in individual whole lymphocytes by electron probe X-ray microanalysis. We use Burkitt's lymphoma cells in culture as the test sample and compare X-ray microanalysis of individual cells with atomic absorption analysis of pooled cell populations. We determine the magnesium peak-to-local continuum X-ray intensity ratio by electron probe X-ray microanalysis and calculate a mean cell magnesium concentration of 39 +/- 19 mmol/kg dry weight from analysis of 100 cells. We determine a mean cell magnesium concentration of 34 +/- 4 mmol/kg dry weight by atomic absorption analysis of pooled cells in three cell cultures. The mean cell magnesium concentrations determined by the two methods are not significantly different. We find a 10% coefficient of variation for both methods of analysis and a 30% coefficient of variation in magnesium concentration among individual cells by electron probe X-ray ...

1986-01-01

320

A sample preparation for quantitative determination of magnesium in individual lymphocytes by electron probe X-ray microanalysis  

International Nuclear Information System (INIS)

We present a sample preparation method for measuring magnesium in individual whole lymphocytes by electron probe X-ray microanalysis. We use Burkitt's lymphoma cells in culture as the test sample and compare X-ray microanalysis of individual cells with atomic absorption analysis of pooled cell populations. We determine the magnesium peak-to-local continuum X-ray intensity ratio by electron probe X-ray microanalysis and calculate a mean cell magnesium concentration of 39 +- 19 mmol/kg dry weight from analysis of 100 cells. We determine a mean cell magnesium concentration of 34 +- 4 mmol/kg dry weight by atomic absorption analysis of pooled cells in three cell cultures. The mean cell magnesium concentrations determined by the two methods are not significantly different. We find a 10% coefficient of variation for both methods of analysis and a 30% coefficient of variation in magnesium concentration among individual cells by electron probe X-ray ...

1986-01-01

321

A computational model for viscous fluid flow, heat transfer, and melting in in situ vitrification melt pools  

Energy Technology Data Exchange (ETDEWEB)

MAGMA is a FORTRAN computer code designed to viscous flow in in situ vitrification melt pools. It models three-dimensional, incompressible, viscous flow and heat transfer. The momentum equation is coupled to the temperature field through the buoyancy force terms arising from the Boussinesq approximation. All fluid properties, except density, are assumed variable. Density is assumed constant except in the buoyancy force terms in the momentum equation. A simple melting model based on the enthalpy method allows the study of the melt front progression and latent heat effects. An indirect addressing scheme used in the numerical solution of the momentum equation voids unnecessary calculations in cells devoid of liquid. Two-dimensional calculations can be performed using either rectangular or cylindrical coordinates, while three-dimensional calculations use rectangular coordinates. All derivatives are approximated by finite differences. The incompressible Navier-Stokes ...

1991-11-01

322

Increasing concentrations of trihalomethanes (THMs) in a drinking water distribution network; Trihalometanos (THMs) en una red de distribucion de agua potable en alta  

Energy Technology Data Exchange (ETDEWEB)

THMs are disinfection by-products (DBPs) generated during water chlorination. Concentration of individual and total THMs, depends on treatment process and THMs precursors level. ATLL water utility has two DWTP (Llobregar and Ter) that produce and supply drinking water to Barcelona and regional area. This work studies the levels of THMs along the ATLL distribution system (450 km). Although, no differences were observed along water pipes system, changes of water resource and mix procedures were related. (Author) 12 refs.

1999-07-01

323

Fundamental R and D program on water chemistry of supercritical pressure water under radiation field  

International Nuclear Information System (INIS)

In a supercritical water-cooled reactor, property of water changes significantly around the critical point. It is expected that irradiation and change of water property will affect the chemistry and material corrosion. Deep understanding of interactions between supercritical water and materials under irradiation is important. However, comprehensive data on radiolysis, kinetics, corrosion and thermodynamics have not been obtained due to the severe experimental condition. To get such data by experiments and computer simulations, a national program funded by Ministry of Education, Culture, Sports, Science and Technology (MEXT) has been started since December 2002. (author)

2003-09-15

324

Evaluation of tritiated water retention capacity of fusion reactor concrete building  

Energy Technology Data Exchange (ETDEWEB)

In this paper the diffusion of tritiated water vapor into concrete walls is studied to evaluate tritiated water retention capacity of a fusion reactor concrete building. Using a model of the tritiated water diffusion determined form experimental results, depth profiles of tritiated water in concrete are calculated in the case of being exposed to air containing tritiated water vapor during the normal operational condition of a fusion reactor. A 0.5-m-thick concrete is sufficient for reactor hall walls from a viewpoint of the tritium containment.

1992-03-01

325

Evaluation of tritiated water retention capacity of fusion reactor concrete building  

International Nuclear Information System (INIS)

In this paper the diffusion of tritiated water vapor into concrete walls is studied to evaluate tritiated water retention capacity of a fusion reactor concrete building. Using a model of the tritiated water diffusion determined form experimental results, depth profiles of tritiated water in concrete are calculated in the case of being exposed to air containing tritiated water vapor during the normal operational condition of a fusion reactor. A 0.5-m-thick concrete is sufficient for reactor hall walls from a viewpoint of the tritium containment.

326

Water management studies in PEM fuel cells, part III: Dynamic breakthrough and intermittent drainage characteristics from GDLs with and without MPLs  

British Library Electronic Table of Contents (United Kingdom)

The transport of liquid water and gaseous reactants through a gas diffusion layer (GDL) is one of the most important water management issues in a proton exchange membrane fuel cell (PEMFC). In this work, the liquid water breakthrough dynamics, characterized by the capillary pressure and water saturation, across GDLs with and without a microporous layer (MPL) are studied in an ex-situ setup which closely simulates a real fuel cell configuration and operating conditions. The results reveal that recurrent breakthroughs are observed for all of the GDL samples tested, indicating the presence of an intermittent water drainage mechanism in the GDL. This is accounted for by the breakdown and redevelopment of the continuous water paths during water drainage as demonstrated by Haines jumps. For GDL ...

2010-01-01

327

Water You Engineering? An Activity to Develop Water-Quality Awareness  

Science.gov (United States)

Water is one of our most precious resources. However, for many in the United States, having fresh, safe drinking water is taken for granted, and due to this perceived lack of relevance, students may not fully appreciate the luxury of having safe running water--in the home. One approach to resolving water-quality issues in the United States may reside in providing education that presents accurate information in a meaningful way. Accordingly, this article describes a unit designed to emphasize the importance of water-quality testing and purification and to introduce students to local water-quality issues. The engineering-based module of this eighth-grade science activity is particularly important due to the design-build-test component. (Contains 5 figures.)

2009-04-01

328

Thermal- and radiation-induced interactions of water on U02 surfaces.  

Energy Technology Data Exchange (ETDEWEB)

Most plans for the disposition of surplus nuclear materials involve storage in sealed containers where the evolution of gases from reactions of adsorbed water could present both pressure and flammability hazards[l] . Despite efforts such as calcining the material to minimize the water content prior to packaging, both residual moisture and readsorbed water may be present in the final containers . Given the anticipated temperature excursions during transportation and storage, this water may thermally desorb, increasing the pressure, and/or thermally dissociate to produce H2 gas, increasing flammability hazards . In addition, the radiation from the nuclear material may induce radiolysis of the water with the likely products being water vapor, H2, 02 and H2O2. In order to better understand the relative importance of the thermal- and radiationinduced chemistry, we ...

2003-01-01

329

Simulation of ground-water flow in the basin-fill aquifer of the Tularosa Basin, south-central New Mexico, ...  

Science.gov (United States)

... percent by interbasin ground-water flow into the Hueco Bolson, and 2 percent by flow into creeks and ... ...

330

Radon concentration measurements at water reservoirs  

International Nuclear Information System (INIS)

Ground water is treated in the Czech Republic so that small water tanks are built above each water source to serve the primary ground water treatment; water so pretreated is then concentrated in large basins for subsequent treatment. Some water tanks where the first contact of the ground water with air takes place were selected as sites predisposed to radon accumulation. The examination was carried out near the town of Jihlava, where the bedrock contains slightly elevated radium concentrations. The average radon concentrations lay within the region of 2-4 kBq/m"3; the instantaneous values, however, exhibited appreciable periodical variations during the day. The relatively high radon concentrations will not pose a marked hazard for the personnel because the employees only reside at the sites in question for 10 to 15 minutes within 2 days, not ...

1998-09-09

332

Performance of single cylinder, direct injection diesel engine using water fuel emulsions  

Energy Technology Data Exchange (ETDEWEB)

A single cylinder diesel engine study of water-in-diesel emulsions was conducted to investigate the effect of water emulsification on the engine performance and gases exhaust temperature. Emulsified Diesel fuels of 0, 5, 10, 15 and 20 water/diesel ratios by volume were used in a single cylinder, direct injection diesel engine, operating at 1200-3300 rpm. The results indicate that the addition of water in the form of emulsion improves combustion efficiency. The engine torque, power and brake thermal efficiency increase as the water percentage in the emulsion increases. The average increase in the brake thermal efficiency for 20% water emulsion is approximately 3.5% over the use of diesel for the engine speed range studied. The proper brake specific fuel consumption and gases exhaust temperature decrease as the percentage of water in the ...

2004-03-01

333

Oreochromis lepidurus  

Science.gov (United States)

... Marine transport and oil disposal by boats and Matadi pose threats in the region. When the water ... Marine transport and oil disposal by boats and Matadi pose threats in the region. When the water ... ...

334

Oceanographic Processes and Marine Productivity in Waters Offshore ...  

Science.gov (United States)

Jun 16, 2011 ... Title: Chapter 21: Oceanographic Processes and Marine Productivity in Waters Offshore of Marbled Murrelet Breeding Habitat ...

335

Ocean Water: Density  

Science.gov (United States)

This site explains how temperature, pressure, and salinity work together to determine the density of ocean water. The three density layers of the ocean are described by means of text description and a graphic illustration.

336

NASA 11x:/,3 '/t.z- - NASA Technical Reports Server  

Science.gov (United States)

_! Packaging, Cleanlines_, Preparation j Handling ..... 35. 'I. 40. WATER ................ , ......... Sterile, High Purity, Ethylene Glycol-Water Solutions. Requirement For . ...

337

N. Mariana Islands Wildlife Action Plan  

Science.gov (United States)

... will utilize man-made habitats, including artificial wetlands, waste water ponds, water hazards on golf courses, and an abandoned ... ...

338

Mathematical modeling of a direct contact humidification?dehumidification desalination process  

British Library Electronic Table of Contents (United Kingdom)

Using air as a carrier gas is common in humidification?dehumidification desalination processes. A computer program was written using mass and energy balances for modeling the process behavior. The parameters considered in this work were inlet air and fresh water recycle temperatures, inlet air flow rate, saline water and fresh water recycle flow rates, and saline water to air flow ratio. Results of simulation showed that increasing inlet air and fresh water recycle flow rate increases fresh water production. It was also found that heating the inlet air to humidification column or cooling the inlet water to dehumidification column increases the production rate but increasing water to air flow ratio in a humidifier leads to a lower production rate. The predicted effects of the parameters on ...

2009-01-01

339

Managing a large outbreak of cryptosporidiosis: how to investigate and when to decide to lift a 'boil water' notice.  

Science.gov (United States)

The largest outbreak of cryptosporidiosis reported in the United Kingdom, involving 575 confirmed cases (of which 474 met an agreed case definition), occurred in the county of Devon during August and September of 1995. The descriptive epidemiology supports the hypothesis that the outbreak was associated with the consumption of cold tap water in the area served by a particular water treatment works. Cryptosporidium oocysts were detected in treated water samples at the time of the outbreak. Although the epidemiological analysis provided strong circumstantial evidence of a waterborne outbreak, the data were not recorded in a manner that made them admissible in criminal proceedings taken by the Drinking Water Inspectorate against the water company involved. The need to carry out an analytical study in conjunction with the identification and characterisation of the pathogen in the ...

2002-09-01

340

MTF ' MISSISSIPPI SOUND REMOTE SENSING STUDY I 19 SEPTEMBER 1972  

Science.gov (United States)

metric temperatures has been prepared showing the surface water temper- ... occasion, gray levels show different densities for similar water temper- ...

341

JPRS Report, Science & Technology, China: Energy  

Science.gov (United States)

... should give full con- As for the effects of the Three Gorges on the mouth of sideration to the rising water process and water temper- the river, the ...

1991-08-23

343

Ground-Water Data for the Suck Creek Area of Walden Ridge ...  

Science.gov (United States)

... Where Suck Creek enters the river, a formidable whirlpool and 2 Ground-water data for the Suck Creek area of Walden Ridge, Southern ...

2011-05-14

344

Fetal cardiotocography before and after water aerobics during pregnancy  

UK PubMed Central (United Kingdom)

ObjectiveTo evaluate the effect of moderate aerobic physical activity in water on fetal cardiotocography patterns in sedentary pregnant women.MethodIn...Full Text Available

345

Equipment for a central heating system with expansion tank, pressure control, water loss supply, de-aeration, recording and control; Apparaat t.b.v. C.V.-installatie met expansievat, drukregeling, waterverliessuppletie, ontluchting, registratie en controle  

Energy Technology Data Exchange (ETDEWEB)

The very low-pressure expansion tank of the title invention is connected to the water in the central heating installation via a connecting pipe with a pump and valves on one side, and on the other side the tank is connected via a connecting pipe with valve to the tap water mains, so that the supply of water can be regulated automatically. Within the expansion tank contact with the outside air is not possible because of an air/water separating floater. By means of recording and control (also remote) of the contents of the expansion tank, the installation pressure and the quantity of supplied water from the expansion tank and the tap water mains, failures and water damage are prevented. 4 figs.

1995-09-01

346

Ecology of Vibrio mimicus in aquatic environments.  

UK PubMed Central (United Kingdom)

An environmental study was done to examine the prevalence of Vibrio mimicus in some aquatic environments of Dhaka, Bangladesh, and of Okayama, Japan. Water samples from Dhaka environments and water...Full Text Available

1989-08-01

347

Density: Sea Water Mixing and Sinking - Aquarius - NASA  

Science.gov (United States)

density is slightly higher, its electrical conductivity is much higher, and it is slightly ... Sea water has characteristic properties (e.g. density) that are independent of ...

348

Assessing vineyard water status using the reflectance based Water Index  

British Library Electronic Table of Contents (United Kingdom)

In the Mediterranean arc, vines for wine production are mainly grown without the support of irrigation. Under such conditions, site variables affecting the extent and seasonal timing of water deficits are the dominant environmental constraints for grape production. Moreover, water availability and vine water status are the factors most comprehensively determining fruit composition and, thus, wine quality. Therefore, monitoring the extent of water stress in vines might be a valuable tool for the optimisation of grape yield and quality. The objective of this study was to evaluate the feasibility of using the reflectance based Water Index (WI) to estimate vine water status at the leaf and canopy levels. The study was conducted on Vitis vinifera cv. Chardonnay potted plants submitted to contra...

2010-01-01

349

Aqueous water-soluble soap lubricant concentrates and aqueous lubricants containing same  

Energy Technology Data Exchange (ETDEWEB)

The inclusion of neodecanoic acid in aqueous water-soluble soap lubricants reduces viscosity, and improves lubricity effectiveness.

1981-06-23

350

Anesthetic stimulation of insect water receptors.  

UK PubMed Central (United Kingdom)

Halothane, chloroform, and carbon tetrachloride, in the vapor and liquid phases, stimulate the water receptor of the blowfly Phormia regina. There are three successive phases of response to long-lasting...Full Text Available

1976-09-01

351

WASTE TREATMENT AND DISPOSAL PROGRESS REPORT FOR JUNE AND JULY 1962  

Science.gov (United States)

9 9 simulated Purex waste oxides was investigated as a function of Na/sub 2/O, CaO and P/sub 2/O/sub 5/ content. All compositions lost some sulfate at 50 to 100 deg C above the softening point. In generai the volatility decreased with increase of either Na/ sub 2/O or CaO relative to P/sub 2/O/sub 5/, but no simple correlation Was indicated. Softening temperatures were lowered by inc ease in Na/sub 2/O vs CaO. Ceramic solids were obtained but no true glasses. Attempts to produce glasses by addition of varying combinations of Al/sub 2/O/sub 3/, PbO, BaO, and B/sub 2/O/ sub 3/ to simulated Pure x waste plus phosphite were unsuccessful. The use of 0.005 M Na/sub 2/C/O/sub 3/ to precipitate calcium from wastes containing up to 3 ppm of phosphate was demonstrated in four pilot plant runs and produced a decrease in the hardness of the waste leaving the clarifier. An inadvertent Sr/ sup 90/ and Cs/sup 137/ breakthrough occurred during one run which was caused ...

1962-12-19

352

The numerical simulation on low-level radioactive waste water, low-temperature cooling water drained effect of implement from the Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

In this paper, we calculated the radioactive concentration distribution of radioactive waste water, the temperature distribution of drained cooling water and the effect of implement from the Daya Bay Nuclear Power Plant on nearby waters range, discussed and analysed some problems of computational results and computation with Alternating Direction Implicit Method (ADI). The contents of the article included: the establishment of two-dimension tidal current equation, radioactive waste water pollutant dispersion equation and cooling water heat convection diffusion equation, the numerical difference calculation model of tidal current field, concentration field as well as temperature field, effect impingement with ADI method, numerical calculation results. The result of research showed that: when the Daya Bay Nuclear Power Plant is on normal operation and after the low level radioactive ...

353

High quality water supply system; Joshitsusui kyokyu system  

Energy Technology Data Exchange (ETDEWEB)

This paper, firstly, introduces the background in developing a high quality water supply system, in which the drinking water system is isolated inside a building. Results of questionnaire on the high quality service water are illustrated. The results of questionnaire have revealed that the high quality service water is extremely interested. Then, are described the target quality of high quality water, the constitution of high quality water supply system, the treatment process, the measures to secure safety and sanitary, and the method of maintenance. The high quality water is produced through the activated charcoal absorption treatment, membrane treatment, ozonation, cooling, mineral addition, and disinfection of city water. Furthermore, application examples of this system adopted to a department store and a bachelor ...

1995-01-15

354

Environmental levels of tritium, 2  

International Nuclear Information System (INIS)

In an attempt to obtain basic data for evaluation of exposure doses in Niigata Prefecture, the concentrations of tritium in atmospheric water, precipitation, river water, and tap water were measured. Samples of atmospheric water, river water, and tap water were collected once for 2 weeks; and precipitation collected for one week was used as sample. The concentration of atmospheric tritium depended on the concentration of tritium in moisture and the content of water in atmosphere. Tritium levels were high in May, November and March, and low in September. Regarding tritium concentrations, there was a good correlation between atmospheric water and precipitation. Tritium concentrations in both of them varied from sample to sample. The concentrations of tritium in river and tap water tended to be high ...

356

Water conservation in agriculture -a step in combating the water crisis  

International Nuclear Information System (INIS)

In Pakistan, the agricultural sector is the largest water user with 95%, leaving only marginal quantities for households and industry. On one hand, agriculture is a very important sector in Pakistan's economic development, contributing about 23 % to the national GDP -but industry contributes slightly more using only about 2 % of the available water resources. As Pakistan faces a growing problem of water shortage, significant achievements in water conservation have to be materialized, predominantly on the agricultural sector. There is scope for a higher degree of efficiency in water use, as water losses, namely in irrigation, are still rather high. There is another good reason for water conservation in agriculture: Over-irrigation results in rising water tables and increased soil salinity, which has reduced Pakistan's ...

2004-06-07

360

THE EFFECTS OF ONE MEGACYCLE ULTRASONIC ...  

Science.gov (United States)

... ULTRASONIC VIBRATION TO PORTLAND CEMENT-WATER PASTE REDUCES THE ULTIMATE COMPRESSIVE STRENGTH OF MORTARS ...

1959-09-09

361

Survey of state water quality standards for wetlands  

Energy Technology Data Exchange (ETDEWEB)

This document summarizes the degree to which State water quality standards include wetlands in their definitions of State waters. The detailed review of other elements of standards, such as uses, criteria and antidegradation, is beyond the scope of this review. The purpose of this review is to provide a baseline of information for the development of EPA guidance and policies related to water quality standards for wetlands.

1989-08-17

364

Sinus Surgery  

Medline Plus

... know if the drainage becomes very clear, like tap water. This may be the first indication that there ...

367

Pillared Clays as Catalysts and Sorbents  

International Science & Technology Center (ISTC)

New Catalysts and Sorbents on the Basis of Pillared Clays for the Processes of Hydrocarbons Conversion and Water Purification

369

Nuclear Thermal Propulsion engine based on Particle Bed Reactor using light water steam as a propellant  

Energy Technology Data Exchange (ETDEWEB)

In this paper the possibility of configuring a water cooled Nuclear Thermal Propulsion (NTP) rocket, based on a Particle Bed Reactor (PBR) is investigated. This rocket will be used to operate on water obtained from near earth objects. The conclusions reached in this paper indicate that it is possible to configure a PBR based NTP rocket to operate on water and meet the mission requirements envisioned for it. No insurmountable technology issues have been identified.

1993-06-01

370

Mormyrops mariae  

Science.gov (United States)

... Marine transport and oil disposal by boats and Matadi pose threats in the region. When the water ... ...

371

Mormyrops curtus  

Science.gov (United States)

... Marine transport and oil disposal by boats and Matadi pose threats in the region. When the water ... ...

372

Member Login | Join / Register with EUGRIS  

Wastenet

...In 2000, the Water Framework Directive (WFD) came into force, introducing a comprehensive, river basin based water management for Europe. The aim of the Directive is ...In 2000, the Water Framework Directive (WFD) came into force, introducing a comprehensive, river basin based water management for Europe. The aim of the Directive ...

375

High resolution neutron imaging of water in the polymer electrolyte fuel cell membrane  

Energy Technology Data Exchange (ETDEWEB)

Water transport in the ionomeric membrane, typically Nafion{reg_sign}, has profound influence on the performance of the polymer electrolyte fuel cell, in terms of internal resistance and overall water balance. In this work, high resolution neutron imaging of the Nafion{reg_sign} membrane is presented in order to measure water content and through-plane gradients in situ under disparate temperature and humidification conditions.

2009-01-01

376

General corrosion of ALLOY 800 in high temperature water and its prevention  

Energy Technology Data Exchange (ETDEWEB)

General corrosion behavior of ALLOY 800 in high temperature water was studied in relation to its surface film structure. The surface film formed in water was found to decrease the corrosion rate of ALLOY 800. This film is composed of Ni ferrite, and can be obtained by oxidation in air or steam. Based on these results, air or steam oxidation treatment to inhibit Ni and Co release of ALLOY 800 into high temperature water is proposed. (author).

1989-10-01

377

General corrosion of ALLOY 800 in high temperature water and its prevention  

International Nuclear Information System (INIS)

General corrosion behavior of ALLOY 800 in high temperature water was studied in relation to its surface film structure. The surface film formed in water was found to decrease the corrosion rate of ALLOY 800. This film is composed of Ni ferrite, and can be obtained by oxidation in air or steam. Based on these results, air or steam oxidation treatment to inhibit Ni and Co release of ALLOY 800 into high temperature water is proposed. (author).

379
381

Evaluation of a computer program used to estimate water characteristic curve  

Science.gov (United States)

The soil water characteristic curve, h(theta), can be used to estimate a variety of parameters in unsaturated soils. One practical application of h(theta) is its use by DRAINMOD, a drainage model that has been widely used in shallow water table regions, to determine the water table depth¿drainage v...

391

Conference on climate and water. Volume 2  

Energy Technology Data Exchange (ETDEWEB)

This book contains the Proceedings of the Conference on Climate and Water under the following groupings: Impacts of climatic variability and change-resulting from the changes in hydrological variables; Aquatic environment; Terrestrial environment; Coastal zones and navigation; Urban and industrial water supply and drainage; Energy production; Intropogenic changes of climate and water management problems; Flood potential; Irrigation and land drainage.

1989-12-31

392

Conference on climate and water  

Energy Technology Data Exchange (ETDEWEB)

This book contains the Proceedings of the Conference on Climate and Water under the following groupings: Impacts of climatic variability and change-resulting from the changes in hydrological variables; Aquatic environment; Terrestrial environment; Coastal zones and navigation; Urban and industrial water supply and drainage; Energy production; Intropogenic changes of climate and water management problems; Flood potential; Irrigation and land drainage.

1989-01-01

393

China's water crisis  

Energy Technology Data Exchange (ETDEWEB)

After the devastating natural disasters that have hit China recently, another crisis is looming, Drought, pollution and heavy usage in the fast-developing megacities have resulted in a shortage of water. A huge construction effort is underway to divert water from the south to the north. But experts warn that it will not solve China's structural water problems.

2008-07-15

394

Aquatic Therapy  

Science.gov (United States)

... use of water in wound management, such as whirlpool baths, but can be used interchangeably with the ...

405

Aerosols Equipment in Manitoba on Environmental Expert  

Wastenet

... Hale, Markku Kulmala, 373.43 EUR; 225.00 USD; 276.00 GBP... Aerosol Chemical Processes in the Environment Spurny, Kvetoslav R., $164,95, 䀈... More Journals » MAGAZINES & JOURNALS Water Science & Technology: Water Supply Water Science and Technology: Water Supply is p... ...

409

46 CFR 63.25-3 - Electric hot water supply boilers.  

Science.gov (United States)

...2010-10-01 false Electric hot water supply boilers. 63.25-3 Section 63.25-3...Boilers § 63.25-3 Electric hot water supply boilers. (a) Electric hot water supply boilers that have a capacity not...

2010-10-01

410

W1045 environment surf drip shield and waste package outer barrier  

Energy Technology Data Exchange (ETDEWEB)

The environments on the drip shield and waste package outer barrier are controlled by the compositions of the waters that contact these components. the temperature (T) of these components, and the effective relative humidity (RH) at these components. Because the composition of the waters that are expected to enter the emplacement drifts (either by seepage flow or by episodic flow) have not been specified: well J13 water was chosen as the reference water (Harrar 1990). Section 6.2 discusses the accessible RH for the temperatures of interest at the repository horizon. Section 6.3 discusses the adsorption of water on metal alloys in the absence of hygroscopic salts. Because the temperatures of the DSs and the WPOBs are higher than those of the surrounding near-field environment, the relative humidity at the DSs and the WPOBs will be lower than that of the surrounding near-field ...

1999-07-14

411

Thermal gradient humidification-dehumidification desalination system  

Energy Technology Data Exchange (ETDEWEB)

A solar energy desalination process utilizing solar radiation directly for the evaporation of salt water is described. Ambient air takes on water vapor as the air passes through an evaporative medium. It is then directed between a saline water-covered, solar absorbing surface and a solar collecting housing. The resulting heated and moisture-saturated air is cooled in a heat exchange means where condensation of fresh water occurs. Simultaneously, cool salt water is utilized as the cooling water in the heat exchange means, and takes on the heat of condensation given up by the condensing vapor. The heated salt water from the heat exchange means is partially directed over the solar absorbing surface, and at least a portion of it is also directed to wet the evaporative medium. Several optional sub-processes are described for operation of the ...

1982-12-14

412

The external water footprint of the Netherlands: Geographically-explicit quantification and impact assessment  

British Library Electronic Table of Contents (United Kingdom)

This study quantifies the external water footprint of the Netherlands by partner country and import product and assesses the impact of this footprint by contrasting the geographically-explicit water footprint with water scarcity in the different parts of the world. The total water footprint of the Netherlands is estimated to be about 2300 m^3/year/cap, of which 67% relates to the consumption of agricultural goods, 31% to the consumption of industrial goods, and 2% to domestic water use. The Dutch water footprint related to the consumption of agricultural goods, is composed as follows: 46% related to livestock products; 17% oil crops and oil from oil crops; 12% coffee, tea, cocoa and tobacco; 8% cereals and beer; 6% cotton products; 5% fruits; and 6% other agricultural products. About 11% o...

2009-01-01

413

Temporal variations of fluoride concentration in Isparta public water system and health impact assessment (SW-Turkey)  

British Library Electronic Table of Contents (United Kingdom)

Water?rock interaction is one of the prime factors affecting the fluoride contents of surface and groundwater. If fluoride concentration of drinking water has been neglected, excess fluoride can cause serious dental and medical problems on human health, which is well known at Golcuk-Isparta region. In the research area, Egirdir lake, Golcuk lake and surrounding springs have been utilized as drinking water sources. Golcuk lake water and surrounding groundwaters have high fluoride content (1.4?4.6?mg/l), which is above the WHO standards. Fluoride is predominantly supplied by dissolution of fluoride within the fluormicas of volcanics during the circulation of water. Fluoride concentrations of waters have shown variations for dry and rainy seasons depending on the degree of interaction between...

2008-01-01

414

Predicting urban forest growth and its impact on residential landscape water demand in a semiarid urban environment  

British Library Electronic Table of Contents (United Kingdom)

We present an innovative approach to estimating residential irrigation water demand for a large metropolitan area using GIS data, weather station data, and a water budget modeling approach commonly used by plant scientists and landscape management professionals. An important question addressed by our study is how a growing urban forest affects the overall irrigation water demand of a semiarid metropolitan area. To estimate the amount of water required by residential landscaping, we consider water demand to be a function of the areal extent of residential landscaping (i.e. tree/shrub or turf grass), the water-loss rate for different landscaping types, the efficiency with which the landscape is irrigated, and local climatic factors (i.e. reference evapotranspiration and precipitation). We es...

2011-01-01

415

Feedwater control device for a reactor  

International Nuclear Information System (INIS)

Purpose: To stably control the reactor water level so as not to cause excess water feeding in a BWR type reactor. Constitution: A flow control valve is disposed to the exit of a feedwater pump for a nuclear reactor and the valve is controlled by a flow regulator to maintain the water level constant in the reactor. A signal from a water level controller is inputted to the flow regulator to thereby control the flow rate control valve. In this case, the flow regulator remains in a saturated state just after the starting of the feedwater pump, in which the pump flowrate is at 100% to result in an excess water feeding condition. In view of the above, a feedback circuit is provided to the flow regulator so that the saturated state is eliminated and the water feeding can be controlled directly from the water level controller. (Kamimura, M.).

1981-11-12

416

Control rod devices  

International Nuclear Information System (INIS)

Purpose: To remove excessive driving pressure applied to an unisolated control rod drive by returning excessive coolant to a condensed water storage tank or to the inlet side of a drive water pump using a coolant flow rate control pipe of a control rod driving hydraulic system. Constitution: Excessive water is returned to a condensed water tank while controlling the excessive coolant by a flow control valve in response to variations in the pressure difference between the reactor pressure and the driving water line when the control rods are isolated using a pipe from the outlet side of the drive water pump to the condensed water storage tank. Thus, the control rod to be isolated is prevented form being dropped. (Sekiya, K.).

417

Assessing variability of water quality in a groundwater-fed perennial lake of Kashmir Himalayas using linear geostatistics  

British Library Electronic Table of Contents (United Kingdom)

This paper presents a study on Manasbal lake, which is one of the high altitude lakes in the Kashmir Valley, India. Eighteen water samples were analysed for major ions and trace elements to assess the variability of water quality of the lake for various purposes. Geostatistics, the theory of regionalized variables, was then used to enhance the dataset and estimate some missing spatial values. Results indicated that the concentration of major ions in the water samples in winter was higher than in summer. The scatter diagrams suggested the dominance of alkaline earths over the alkali elements. Three types of water were identified in the lake that are referred to as Ca?HCO3, Mg?HCO3 and hybrid types. The lake water was found to be controlled by rock?water interaction with carbonate lithology ...

2011-01-01

418

Assessing Ground Water Development Potential Using Landsat Imagery  

British Library Electronic Table of Contents (United Kingdom)

Seven villages in southeastern Kenya surround Mt. Kasigau and depend on the mountain's cloud forest for their water supply. Five of these villages have regularly experienced water shortages, and all village water supplies were contaminated with Escherichia coli bacteria. There is a need to economically find new sources of fresh ground water. Remote sensing offers a relatively quick and cost-effective way of identifying areas with high potential for ground water development. This study used spectral properties of features on Landsat remote sensing imagery to map linear features, soil types, surface moisture, and vegetation. Linear features represented geologic or geomorphologic features indicating either shallow ground water or areas of increased subsurface hydraulic conductivity. Regarding...

2010-01-01

419

Ultratrace analysis of mercury and methylmercury (MM) in rain water using cold vapor atomic absorption spectrometry  

Energy Technology Data Exchange (ETDEWEB)

Ultratrace analysis of mercury in rain water has been investigated, including recovery of ionic mercury with the addition of acids, treatment and storage and stability studies of mercury in rain water. Recovery of ionic mercury from rain water samples increased with increased acid concentrations and increased substantially with UV-irradiation. Recovery of ionic mercury in the presence of different acids was compared. Treatment studies of rain water for the analysis of total mercury were done using different decomposition methods. More than 20% of the total mercury was found in rain water residue after filtration through 0.45 ..mu..m membrane filters. Methylmercury (MM) content in filtered and unfiltered rain water however was nearly the same. On long term storage of rain water without acids at pH = 2.0 and 4.5 loss of total mercury occurred, ...

1987-03-01

420

Tritium in surface waters, tap water and in precipitation in Poland during the 1994-1999 period  

International Nuclear Information System (INIS)

Concentrations of tritium in environmental waters (precipitation, rivers, lakes, tap water) have been determined using electrolytic enrichment and liquid scintillation counting. In waters of big rivers (the Vistula and the Odra rivers), lakes and tap water the annual average concentrations were similar to each other being from 1.4 to 1.9 Bq x dm"-"3. These concentrations were similar to those in the precipitation in which they ranged from 1.7 to 2.2 Bq x dm"-"3. The lowest tritium concentrations were found in waters of the Seashore Region rivers (average for 1994-1999 was 1.1 Bq x dm"-"3). The tritium concentrations in surface waters and in precipitation are still higher than that of natural level. The data obtained show that tritium concentration in the water of rivers might depend on the size of drainage area. The observed seasonal ...

2001-01-01

421

The use of isotopes in hydrology: Proceedings of a symposium, held in Beirut -Lebanon, December 1970  

International Nuclear Information System (INIS)

The papers presented at the symposium had covered three general areas in which isotopes could have been beneficially used. these areas are: -Water use and water use efficiency studies. -Ground water investigations -Water problems in the arab countries. The individual papers had dealt with these subjects: -Hydrological research in the arab countries by use of radioisotopes. -The perspectives of use of radioisotopes in hydrological studies in Syria. -Water use efficiency and sub-soil water studies. -Sea water inclusion in a coast el aquifers in Lebanon. -Irrigation requirements of crops in Lebanon as determined by a Neutron probe with reference to other methods. -The use of the neutron moisture meter and other methods of the determination of the evapotranspiration of maize. -Ground water investigations, dating and nuclear ...

1970-12-01

422

Soil water retention at varying matric potentials following repeated wetting with modestly saline-sodic water and subsequent air drying  

Energy Technology Data Exchange (ETDEWEB)

Coal bed natural gas (CBNG) development in the Powder River (PR) Basin produces modestly saline, highly sodic wastewater. This study assessed impacts of wetting four textural groups (0-11%, 12-22%, 23 -33%, and > 33% clay (g clay/100 g soil) x 100%))with simulated PR or CBNG water on water retention. Soils received the following treatments with each water quality: a single wetting event, five wetting and drying events, or five wetting and drying events followed by leaching with salt-free water. Treated samples were then resaturated with the final treatment water and equilibrated to -10, -33, -100, -500, or -1,500 kPa. At all potentials, soil water retention increased significantly with increasing clay content. Drought-prone soils lost water-holding capacity between saturation and field capacity with repeated wetting and drying, ...

2007-07-01

423

Low temperature humidification dehumidification desalination process  

Energy Technology Data Exchange (ETDEWEB)

The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling water. The ...

2006-03-01

424

Low temperature humidification dehumidification desalination process  

International Nuclear Information System (INIS)

The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling water. The ...

2006-03-01

425

Glass Transition Behaviors of Ethylene Glycol-Water Solutions Confined within Nano-Pores of Silica Gel  

Science.gov (United States)

Enthalpy relaxation properties of the ethylene glycol (EG) aqueous solutions confined within silica-gel void spaces of 1.1 nm in the average void thickness and 6, 12 and 52 nm in their average diameters were examined by an adiabatic calorimetry to understand the glass transition behavior of the solutions and the rearrangement processes of the molecules. The glass transition temperature Tg of EG was found to decrease with adding the water molecules which are mobile under the condition lacking in the full hydrogen-bond network. Meanwhile, the Tg in the water-rich region showed a rise towards pure water; after a phase separation in a 25 mol% (x = 0.25) EG solution, the Tg was 160 K which was higher than that derived by extrapolating the composition dependence to pure water. The Tg = 160 K is the same as observed in the pure water confined within 1.1 nm voids; this indicates the ...

2008-02-01

426

Use of the ADINA (Automatic Dynamic Incremental Nonlinear Analysis) computer code on a COSA II (Computer Codes for Salt) benchmark computer case of the local area - progress report 1990  

International Nuclear Information System (INIS)

The COSA II (computer codes for salt) benchmark problem has been pursued with the ADINA (Automatic Dynamic Incremental Nonlinear Analysis) program code. With the use of this, the code should be validated by means of experimental data and the ability to reproduce real-life calculation results of the KfK (Kernforschungszentrum Karlsruhe/Nuclear Research Center in Karlsruhe) should be proven. A successful validation of the code then forms the foundation stone for the ability to use different calculation problems in the final (ultimate) storage. This also accompanies the consequent reaction of replacing the STEALTH (Solids and Thermal Hydraulics Code for EPRI Adapted from LAGRANGE TOODY and HEMP) program which has a number of program-specific weaknesses compared to the ADINA computer code. In order to reproduce the approximate values from the KfK, the same values have been used. Differences were evident in the discretion and the selection of the initial values for pressure and temperature. ...

427

Simplified fusion power plant costing. A general prognosis and call for `new think`  

Energy Technology Data Exchange (ETDEWEB)

A top-level costing model is developed and used to project the cost of electricity (COE) (in mills per kilo watt-hour) expected from conceptual fusion power plants. Application is restricted to magnetic fusion energy (MFE) concepts. These costs are estimated parametrically in terms of the mass of the fusion-power-core (FPC) heater, the power required to sustain a reacting deuterium-tritium plasma, the heat transport/transfer system that delivers the fusion power to the balance of plant (BOP), and the BOP needed to convert the fusion heat to electrical power. Although the highly integrated (simplified) cost-estimating relationships (CERs) used to express COE in terms of FPC mass power density (MPD) [in kilowatt(electric) per tonne] and the engineering gain Q{sub E} (inverse of fraction of gross electric power recirculated to the fusion power plant) apply primarily to MFE approaches to fusion power, the costing gauge thus results is generally independent of ...

1995-03-01

428

Pulse power considerations for the generation of 45 #mu#s, 200 keV electron beams for CO_2 lasers  

International Nuclear Information System (INIS)

A two module electron beam source operating over a wide range of output parameters has been designed and fabricated to be used in conjunction with a pair of electron beam sustained CO_2 lasers. Each module comprised a grid-controlled thermionic electron beam gun including a compact grid pulser for control of the electron beam, a 250 kV thyratron switched modulator for acceleration of the electron beam, a 1 kHz filament heater and a complex computerized control system. The system was designed to reliably produce 45 #mu#s wide electron pulses of 150-200 keV energy, operate at repetition rates of 1-10 pps and current densities of 5-20 mA/cm"2. Additional parameters are listed. The high voltage cathode assembly employs 132 thoriated tungsten filaments distributed over the area of the 250 cm x 10 cm output window. The cathode assembly including the control grids is supported by two high voltage ceramic bushings in a stainless steel vacuum chamber. For acceleration of ...

1989-01-19

429

Performance test of a small compact combined heating and electricity generating plant; Erfolgskontrolle Klein-Blockheizkraftwerk  

Energy Technology Data Exchange (ETDEWEB)

The present project examined the operating characteristics and application possibilities of a new, compact combined heating and electricity generating unit with a thermal output of 14,5 kW and a generating capacity of 5,5 kW. Such a module was installed in a plant in Arlesheim (Canton of Basel-Country) and subject to performance measurements. The small heating and generating plant is designed for cyclic operation (without heat storage) and is very compact and low in cost. The heating and generating unit conforms to all Swiss regulations relating to electrical installations and air pollution control. The NO{sub x} emissions of the unit (400 mg/m{sup 3} in steady state operation) are above the limits of LRV 92 (80 mg/m{sup 3}), but the regulation does not apply for units in this power range. The electricity generation costs are approximately CHF 0.16/kWh. It therefore makes sense to install the module in regions with average supply tariffs of at least CHF 0.16/kWh. Ideal locations are ...

1995-12-01

430

Kelvin-day function for climatic solar heating design  

Energy Technology Data Exchange (ETDEWEB)

A method of Kelvin-day function for climatic solar heating design is presented. The long term temperature distribution is used to find the solar fraction for building heating. A solar heating system is considered to provide heat needed up to an auxiliary heater cut-in temperature which is determined by both heat gain of solar heating system and overall heat loss coefficient of the building. The amount of auxiliary heat needed is calculated from a Kelvin-day value at this cut-in temperature. The cut-in temperature will change from different solar heating system designs, and the Kelvin-day value at this cut-in temperature will be varied. By using the numerical curve-fitting method, the Kelvin-day value at any temperature base can be expressed into a second order algebraic equation, thus, the whole data need not be put into computer storage. It will be very convenient to determine the Kelvin-day value at any base in the design of small heating buildings for ...

1981-01-01

431

Geothermal heat cycle research: Supercritical cycle with horizontal counterflow condenser  

Energy Technology Data Exchange (ETDEWEB)

The Heat Cycle Research Program, which is being conducted for the Department of Energy, has as its objective the development of the technology for effecting the improved utilization of moderate temperature geothermal resources. To meet this objective, the program has as one of its goals to improve the performance of geothermal binary cycles to levels approaching the practicable thermodynamic maximum. In pursuit of this goal, tests are being conducted at the Heat Cycle Research Facility located at the DOE Geothermal Test Facility, East Mesa, California. The current testing involves the investigation of binary power cycle performance utilizing mixtures of non-adjacent hydrocarbons as the working fluids, with supercritical vaporization and in-tube condensation of the working fluid. In addition to the present test program, preparations are being made to investigate the binary cycle performance improvements which can be achieved by allowing supersaturated vapor expansions in the turbine. ...

1987-01-01

432

Future radioisotope power needs for missions to the solar system  

Energy Technology Data Exchange (ETDEWEB)

NASA and DOE plan a cooperative team effort with industry, government laboratories and universities to develop a near term, low cost, low power (100 watt electric class), low mass (<10 kg), advanced radioisotope space power source (ARPS) and in the process reduce the plutonium-related costs as well. The near term is focused on developing an advanced energy converter to use with the General Purpose Heat Source (GPHS). The GPHS was developed and used for the current radioisotope thermoelectric generators (RTGs). Advanced energy converter technologies are needed as a more efficient replacement for the existing thermoelectric converters so that the space radioisotope power source mass and cost can be reduced. a more advanced technology space radioisotope power system program is also planned that addresses a longer-term need. Twenty first century robotic scientific information missions to the outer planets and beyond are planned to be accomplished with microspacecraft which may demand ...

1997-12-31

433

Engineering Development of Coal-Fired High-Performance Power Systems  

Energy Technology Data Exchange (ETDEWEB)

A High Performance Power System (HIPPS) is being developed. This system is a coal-fired, combined cycle plant with indirect heating of gas turbine air. Foster Wheeler Development Corporation and a team consisting of Foster Wheeler Energy Corporation, Bechtel Corporation, University of Tennessee Space Institute and Westinghouse Electric Corporation are developing this system. In Phase 1 of the project, a conceptual design of a commercial plant was developed. Technical and economic analyses indicated that the plant would meet the goals of the project which include a 47 percent efficiency (HHV) and a 10 percent lower cost of electricity than an equivalent size PC plant. The concept uses a pyrolysis process to convert coal into fuel gas and char. The char is fired in a High Temperature Advanced Furnace (HITAF). The HITAF is a pulverized fuel-fired boiler/air heater where steam is generated and gas turbine air is indirectly heated. The fuel gas generated in the ...

2000-12-31

434

Development of a Commercial Process for the Production of Silicon Carbide Fibrils  

Energy Technology Data Exchange (ETDEWEB)

The current work continues a project completed in 1999 by ReMaxCo Technologies in which a novel, microwave based, VLS Silicon Carbide Fibrils concept was verified. This project continues the process development of a pilot scale commercial reactor. Success will lead to sufficient quantities of fibrils to expand work by ORNL and others on heat exchanger tube development. A semicontinuous, microwave heated, vacuum reactor was designed, fabricated and tested in these experiments. Cylindrical aluminum oxide reaction boats are coated, on the inner surface, with a catalyst and placed into the reactor under a light vacuum. A series of reaction boats are then moved, one at a time, through the reactor. Each boat is first preheated with resistance heaters to 850 C to 900 C. Each reaction boat is then moved, in turn, to the microwave heated section. The catalyst is heated to the required temperature of 1200 C to 1300 C while a mixture of MTS (methyl trichlorosilane) and ...

2003-04-22

435

Comparison between experimental data and numerical modeling for the natural circulation phenomenon  

Energy Technology Data Exchange (ETDEWEB)

There is a crescent interest in the scientific community in the study of natural circulation phenomenon. New generation of compact nuclear reactors uses the natural circulation of the fluid as a system of cooling and of residual heat removal in case of accident or shutdown. The objective of this paper is to present a study through the comparison of experimental data and numerical simulation for the natural circulation phenomenon in one and two-phase flow regime. An experimental circuit built with glass tubes is used for the experiments. Thus, it allows the thermal hydraulic phenomena visualization. There is an electric heater as the heat source, a heat exchanger as the heat sink and an expansion tank to accommodate fluid density excursions. The circuit instrumentation consists of thermocouples and pressure meters to better keep track of the flow and heat transfer phenomena. Instrumentation data acquisition is performed through a computer interface developed with ...

2009-07-01

436

The use of treated wastewater for chemlali olive tree irrigation: effects on soil properties, growth and oil quality  

Energy Technology Data Exchange (ETDEWEB)

Olive tree (Olea european L.) cultivation, the major tree crops in Mediterranean countries is being extended to irrigated lands. However, the limited water availability, the severe climatic conditions and the increased need for good water quality for urban and industrial sector uses are leading to the urgent use of less water qualities (brackish water and recycled wastewater) for olive tree irrigation. The aim of this work was to asses the effects of long term irrigation with treated waste water (TWW) on the soil chemical properties, on olive tree growth and on oil quality characteristics. (Author)

2009-07-01

437

Method for limiting scram discharge water  

International Nuclear Information System (INIS)

Object: To limit the discharge amount of reactor water in a primary system at the time of scram to prevent excessive outflow of reactor water outside the system. Structure: A signal from an upper limit position indicator detects the fact that control rods are completely inserted when the reactor is urgently stopped and the detection signal causes a valve in an outflow line of the discharge water from a control rod driving mechanism to be closed to limit the amount of discharge flown into the scram discharge vessel, thus preventing outflow of reactor water in the primary system after the scram has been initiated. (Kamimura, M.).

438

Experimental study on the texture of falling water of free falling and slope falling types; Jiyu rakkagata to etsuryugata no rakusui hyojo ni tsuite no jikkenteki kenkyu  

Energy Technology Data Exchange (ETDEWEB)

A full scale experiment was carried out to investigate the texture characteristics of the falling water of free falling and slope failing types. According to the increase of Reynolds number, the texture of falling water was classified into three categories for both types: stability of free surface, transition and whole turbulence. In the first category the stability of the free surface was related to the growth of minute disturbance. Surface tension works as a counter, force to the disturbance in free falling water, and gravity in slope falling water. 14 refs., 15 figs., 3 tabs.

1998-05-21

439

Development of a geothermal heat pump. Final report  

Energy Technology Data Exchange (ETDEWEB)

In the development of a geothermal heat pump a water source heat pump was connected to a 1-1/2'' water line, 2200' long, buried in an endless loop 10' deep. The system is closed, circulating the same water continuously through the heat pump back to the field again. This water line 10' deep is the geothermal heat source. No matter how cold the air temperature gets on a winter day the water temperature to the heat pump will always be above 45/sup 0/F. This system has efficiently heated our house the past year using no supplemental heat.

1981-11-02

440

The use of oxygen isotopic composition to study water dynamics in Amazon floodplain lakes  

International Nuclear Information System (INIS)

The lakes formed in the Amazon floodplain play a key role in sustaining the highest populational density in the Amazon Basin because of its high primary productivity. The water volume in these lakes vary greatly during the year and possible water sources are the feeding river during high water state of the hydrographs and local inputs from its drainage basin. As these sources are chemically distinct, to understand the nutrient dynamics in these lakes, it is very important to know the relative water contribution of different water sources. In this paper we use "1"8O as a conservative to know the water sources for the lakes and our hypothesis is that: 1) In the high water stage lake water is derived predominantly from its feeding river. Therefore their #delta#"1"8O should be similar. 2) In the low ...

1989-05-01

441

Wear resistant composite structure of vitreous carbon containing convoluted fibers. Quarterly report number 2  

Energy Technology Data Exchange (ETDEWEB)

The program goals for the first quarter were to located and contact potential manufacturers of these components, evaluate their level of interest, and begin discussions of the type and design of the prototypes to be fabricated for their evaluation. Thoughtful discussion at this stage would result in fabricating prototypes which answer the greatest number of questions possible for a given manufacturer at the lowest cost to this program. In the present economy many manufacturing firms have almost no funds for testing and evaluating new materials. This places a greater burden on the data obtained from outside laboratories. In many cases this data will be used to make that first evaluation on MRCC`s (metal reinforced carbon composites) suitability for a given application and give firms the confidence to commit to a evaluation program. In Exhibit 1, which is attached to this report the authors have the first set of data from outside laboratories. This has been incorporated into a paper ...

1994-11-01

442

The use of biodegradable polylactic acid barrier materials in the treatment of grade II periodontal furcation defects in humans--Part II: A multicenter investigative surgical study.  

Science.gov (United States)

This study evaluated whether differences in design of 3-dimensional polylactic acid barriers (EPi-Guide and Guidor) would influence hard tissue results in the treatment of Grade II furcations in humans. A multicenter study was conducted, using 40 patients with moderate to advanced bilateral chronic adult periodontitis of the mandibular first or second molars. After flap access, debridement, and root preparation, surgical bone level measurements were taken and membranes were placed on a random basis. Surgical reentry occurred at 1 year. Data collected from all 3 investigative centers were pooled and analyzed using an analysis of variance appropriate for a counterbalancing design. Both barrier materials resulted in significant gains of attachment level and defect reduction. The composite reduction in the vertical component of the osseous defects was greater in the sites treated with Epi-Guide as compared to those treated with Guidor; the difference between barriers ...

1999-02-01

443

The Polytechnique, UQAT, NSERC chair in environment and tailings management; La Chaire Polytechnique, UQAT, CRSNG en environnement et gestion des rejets miniers  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this new industrial chair is to ensure the continuation and development of new research activities in the field of environment protection as it relates to the good management of mine tailings. The mining industry plays a vital role in the economy of a number of regions in both Quebec and Canada and also causes environmental problems due to the generation of liquid, solid, and gaseous wastes. Mine tailings can cause acid mine drainage. This acid mine drainage (AMD) can have detrimental effects on the ecosystems adjoining tailings or waste rock piles. We must remain aware that some of the remedial measures instituted to contain AMD might cause problems due to their possible instability. Despite the fact that instability is a rare occurrence, it can have disastrous effects on the environment as demonstrated in Spain, Guyana, and the Philippines during the last few years. The creation of this chair in environment and tailings management will allow the consolidation of ...

2000-07-01

444

Studies on magnetohydrodynamic flow characteristics and heat transfer of liquid metal two-phase flow cooling systems for a magnetically confined fusion reactor  

Energy Technology Data Exchange (ETDEWEB)

Liquid metal cooling for the first wall and blanket of a magnetic confinement fusion reactor has various advantages. However, it has the disadvantages of large magnetohydrodynamic pressure drops and heat transfer deterioration under a strong magnetic field. Thus, the present authors have proposed cooling with a helium-lithium annular mist flow as well as the cooling with a liquid metal boiling flow, and as fundamental studies, investigated the effect of a magnetic field on the flow characteristics and heat transfer of liquid metal two-phase systems since the 1970s. In the present paper we summarize the important findings obtained from our experimental studies for (i) an air-mercury stratified flow in a horizontal rectangular channel, (ii) a helium-lithium annular mist flow in a horizontal rectangular channel, (iii) the mercury pool boiling on a horizontal surface, and (iv) air-mercury upward flows in a vertical circular tube. Based on the results, the research ...

1995-03-01

445

Studies on magnetohydrodynamic flow characteristics and heat transfer of liquid metal two-phase flow cooling systems for a magnetically confined fusion reactor  

International Nuclear Information System (INIS)

Liquid metal cooling for the first wall and blanket of a magnetic confinement fusion reactor has various advantages. However, it has the disadvantages of large magnetohydrodynamic pressure drops and heat transfer deterioration under a strong magnetic field. Thus, the present authors have proposed cooling with a helium-lithium annular mist flow as well as the cooling with a liquid metal boiling flow, and as fundamental studies, investigated the effect of a magnetic field on the flow characteristics and heat transfer of liquid metal two-phase systems since the 1970s. In the present paper we summarize the important findings obtained from our experimental studies for (i) an air-mercury stratified flow in a horizontal rectangular channel, (ii) a helium-lithium annular mist flow in a horizontal rectangular channel, (iii) the mercury pool boiling on a horizontal surface, and (iv) air-mercury upward flows in a vertical circular tube. Based on the results, the research ...

446

Short rotation coppice with Robinia pseudoacacia L. : a land use option for carbon sequestration on reclaimed mine sites  

Energy Technology Data Exchange (ETDEWEB)

A study in northeast Germany has shown that the establishment of short rotation coppices (SRC) of Robinia pseudoacacia L. may be a viable option for improving farmers income on marginal soils. The plantations produce woody biomass at a fast rate for energy use. Carbon is accumulated in the harvestable biomass, as well as in the stump and the roots. These plant compartments form a long-term carbon storage pool because they can survive a harvest, stay vital at the site and continue to grow as the plant ages. As organic litter decomposes, additional carbon is sequestered under SRC as soil organic carbon. The carbon sequestration in SRC of R. pseudoacacia on mining sites within the Lower Lusatian region in northeast Germany was studied and the results were complemented with findings of current field studies conducted on reclaimed mine sites. The average above ground dry matter productivity of R. pseudoacacia was found to be 3 to 10 Mg per hectare per year, depending on ...

2010-07-01

447

Results of in-house cone-cup testing of low to high temperature SPF-alloys  

Energy Technology Data Exchange (ETDEWEB)

Material testing of SPF-sheet is usually done with coupon hot tensile testing. The optimum range of strain rates is determined with stepped strain tests. To overcome the problem of very few available testing facilities and time consuming and costly procedure, cone cup testing has been developed since long. This test can be generated directly in the workshop, no machining of samples is necessary and it is very much related to the real SPF-process. The analysis of suitable temperature and strain rate is done by simple measurement of resulting cone height. This paper describes a unique and novel variant of the above mentioned baseline design. It provides on-line data of the actual status of the cone cup forming resulting from the applied, constant pressure. Strain rate variations as a result from texture or from the alloy-related behaviour is detectable. Thinning and ''hardening'' behaviour of different alloys up to maximum failure strain can be ...

2004-07-01

448

Research and development of neutron radiography in IAERU  

Energy Technology Data Exchange (ETDEWEB)

In the Institute for Atomic Energy, Rikkyo University, just after the TRIGA-2 research reactor of 100 kW has attained the criticality, the cylindrical box for neutron radiography (NR) irradiation was made in the attached pool, and the research on NR was started in 1961. Thereafter in 1985, the vertical irradiation pipe was installed in the reactor tank, and the experiment for collecting the basic data was begun. In 1986, based on the obtained data, the NR irradiation facility on full scale was installed in No. 2 tangential horizontal experimental hole. As the main NR irradiation facilities, the vertical neutron irradiation pipe, the use of which is stopped now, the NR facility using the horizontal experimental hole (RUR/N2), the irradiation facility and ancillary facilities such as beam shutter, beam catcher and hoist are described. As the main equipments for NR, the imaging apparatuses of cooled type CCD, SIT and superhigh sensitivity, the image processors of ...

1995-03-01

449

Removal rate of ( sup 3 H)hyaluronan injected subcutaneously in rabbits  

Energy Technology Data Exchange (ETDEWEB)

Hyaluronan is an important constituent of the extracellular matrix in skin, and recent studies suggest that there is a pool of easily removable (free) hyaluronan drained by lymph. The removal rate of free hyaluronan in skin was measured from the elimination of ({sup 3}H)hyaluronan, injected subcutaneously in 13 rabbits. The removal of radioactivity was determined from appearance of {sup 3}H in plasma. During the first 24 h after injection, 10-87% of the tracer entered blood, less in injectates with high concentrations of hyaluronan. The removal was monoexponential with a half-life of 0.5-1 day when concentration of hyaluronan was 5 mg/ml or less. When hyaluronan concentration was 10 mg/ml or higher, the removal was slow for about 24 h and then became similar to that in experiments with low hyaluronan concentration. Free hyaluronan at physiological concentrations is thus turned over with the same rate as serum albumin, supporting the concept that hyaluronan is ...

1990-08-01

450

Radon concentration measurements in mofettes from Harghita and Covasna Counties, Romania  

Energy Technology Data Exchange (ETDEWEB)

In the Harghita volcanic range (Romania) there are many occurrences of dry CO{sub 2} emanations, called mofettes. The emanating gas with high carbon dioxide content has a proved curative effect. The gas also contains important quantities of radon. Since the mofettes are used in curative purposes in several illnesses, in most of the cases without medical supervising, has been proposed to determine the radon activity concentration in some of the most frequented mofettes from Romania. The seasonal variations have also been monitored and were calculated the effective doses received by the patients during a cure. The radon activity concentrations' levels above the mofettes indoor air range between 548 and 10 717 Bq/m{sup 3} while within the gas pools' values between 3210 and 32 781 Bq/m{sup 3} have been measured. The effective dose received by the patients during a cure is between 0.0086 and 0.16 mSv. No major seasonal variations of the radon activity ...

2008-12-15

451

Radon concentration measurements in mofettes from Harghita and Covasna Counties, Romania  

International Nuclear Information System (INIS)

In the Harghita volcanic range (Romania) there are many occurrences of dry CO2 emanations, called mofettes. The emanating gas with high carbon dioxide content has a proved curative effect. The gas also contains important quantities of radon. Since the mofettes are used in curative purposes in several illnesses, in most of the cases without medical supervising, has been proposed to determine the radon activity concentration in some of the most frequented mofettes from Romania. The seasonal variations have also been monitored and were calculated the effective doses received by the patients during a cure. The radon activity concentrations' levels above the mofettes indoor air range between 548 and 10 717 Bq/m3 while within the gas pools' values between 3210 and 32 781 Bq/m3 have been measured. The effective dose received by the patients during a cure is between 0.0086 and 0.16 mSv. No major seasonal variations of the radon activity concentrations levels have been ...

2008-12-01

452

Radiolabeling of oligofructans with CO sub 2 in excised wheat leaves  

Energy Technology Data Exchange (ETDEWEB)

The authors studied the flow of carbon ({sup 14}C) from CO{sub 2} through sucrose to oligofructans in wheat (Triticum aestivum L.) leaves that had been induced by excision to accumulate fructan. Leaves were either labeled for 30 min and then chased in ambient air for 2 h or labeled continuously for 2 h. Fructans were chromatographed on BioGel P2 column. During continuous labeling, the specific activity was highest in sucrose and decreased for fructans with DP 3 to 5, and each increased linearly with time for 2 h. During the chase period, sucrose specific activity increased for 60 min and then declined while oligofructans gained in specific activity through the 2 h period. After 30 min of labeling, the specific activity of fructose moiety of sucrose was equal to glucose but, in oligofructans, those of the individual fructose units were not. The results may provide insight into the fructosyl donor-acceptor pool relations in wheat leaves.

1989-04-01

453

Prolonged swimming exercise training induce hypophosphatemic osteopenia in stroke-prone spontaneously hypertensive rats (SHRSP).  

Science.gov (United States)

Stroke-prone spontaneously hypertensive rats (SHRSP) induce spontaneous osteoporosis. To elucidate the specific characteristics of bone metabolism, the SHRSP was compared with age matched Wistar-Kyoto (WKY) rats. We investigated the effects of prolonged swimming exercise training on bone mineral density (BMD) and metabolism in the SHRSP. Seven-week-old male SHRSP and WKY were divided into three groups; the sedentary control WKY group (n = 6, WKY), the sedentary control SHRSP group (n = 6, SP) and the swimming exercise training SHRSP group (n = 6, SWIM) (in pool with 60 min./day, 5 days/week for 12 weeks). The femoral BMD, bone mineral content (BMC), strength, Ca and P contents (%) of SHRSP were approximately 17, 27, 25, 20 and 9%, respectively, lower than that of WKY (p swimming exercise training in the SHRSP induces more cruelly hypophosphatemia, and leading to osteopenia eventually. We conclude that SHRSP induces osteopenia with disturbance of phosphate ...

2000-11-01

454

Process model for carbothermic production of silicon metal  

Energy Technology Data Exchange (ETDEWEB)

This thesis discusses an advanced dynamical two-dimensional cylinder symmetric model for the high temperature part of the carbothermic silicon metal process, and its computer encoding. The situation close to that which is believed to exist around one of three electrodes in full-scale industrial furnaces is modelled. This area comprises a gas filled cavity surrounding the lower tip of the electrode, the metal pool underneath and the lower parts of the materials above. The most important phenomena included are: Heterogeneous chemical reactions taking place in the high-temperature zone (above 1860 {sup o}C), Evaporation and condensation of silicon, Transport of materials by dripping, Turbulent or laminar fluid flow, DC electric arcs, Heat transport by convection, conduction and radiation. The results from the calculations, such as production rates, gas- and temperature distributions, furnace- and particle geometries, fluid flow fields etc, are presented graphically. ...

1995-09-12

455

Performance of a modified two-dimensional gamma scan system in spent fuel pin studies  

International Nuclear Information System (INIS)

This work assesses the performance of a modified two-dimensional gamma scan system in spent fuel pin studies. The techniques for a two-dimensional gamma scan studied have been developed at the Hot Cell of Institute of Nuclear Energy Research (INER). Samples are acquired from the spent fuel pin, TPC-SP-C1, which was irradiated in a commercial reactor core (the first of its kind in Taiwan) for 2 years and then deposited in a cooling pool for 10 years. The spent fuel pin was then transferred into INER for further examination. The gamma scanning system was driven by a step motor which had an accuracy within 0.1 mm in both X-Y directions. Data obtained from this system are presented in both an isotopic distribution and contour plot. Results in this study closely correspond to those in other investigations, thereby confirming the effectiveness of this modified system. (author)

1999-11-01

456

Partitioning and transport of the translocates mannitol and sucrose in the light and dark in celery (Apium Graveolens L. )  

Energy Technology Data Exchange (ETDEWEB)

Sucrose and mannitol are major photosynthetic products and translocates in celery. Assimilate partitioning and transport were studied by pulse-labeling leaves with /sup 14/CO/sub 2/ followed by different length chases in ambient air. After a 2 h chase in the light there was more /sup 14/C in sucrose than mannitol in source leaves and their petioles. In contrast after a 2 h dark chase leaves contained more /sup 14/C in mannitol than sucrose but petioles had more /sup 14/C in sucrose than mannitol. After a 15 h chase (6 h light; 9 h dark) labeled sucrose was higher in source petiole vascular bundles than in adjacent parenchyma tissue but label in glucose and fructose was higher in the parenchyma tissue. After the 15 h chase most of the /sup 14/C remaining in developing sink leaves and their petioles was in mannitol. Although in the light mannitol:sucrose ratios are the same in leaf and petiole tissues, in the dark sucrose is initially the major translocate with mannitol becoming more ...

1987-04-01

457

Optimal security-constrained power scheduling by Benders decomposition  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a Benders decomposition approach to determine the optimal day-ahead power scheduling in a pool-organized power system, taking into account dispatch, network and security constraints. The study model considers the daily market and the technical constraints resolution as two different and consecutive processes. The daily market is solved in a first stage subject to economical criteria exclusively and then, the constraints solution algorithm is applied to this initial dispatch through the redispatching method. The Benders partitioning algorithm is applied to this constraints solution process to obtain an optimal secure power scheduling. The constraints solution includes a full AC network and security model to incorporate voltages magnitudes as they are a critical factor in some real power systems. The algorithm determines the active power committed to each generator so as to minimize the energy redispatch cost subject to dispatch, network and ...

2007-05-15

458

Optimal Control of Thermo--Fluid Phenomena in Variable Domains  

Science.gov (United States)

This presentation concerns our continued research on adjoint--based optimization of viscous incompressible flows (the Navier--Stokes problem) coupled with heat conduction involving change of phase (the Stefan problem), and occurring in domains with variable boundaries. This problem is motivated by optimization of advanced welding techniques used in automotive manufacturing, where the goal is to determine an optimal heat input, so as to obtain a desired shape of the weld pool surface upon solidification. We argue that computation of sensitivities (gradients) in such free--boundary problems requires the use of the shape--differential calculus as a key ingredient. We also show that, with such tools available, the computational solution of the direct and inverse (optimization) problems can in fact be achieved in a similar manner and in a comparable computational time. Our presentation will address certain mathematical and computational aspects of the method. As an ...

2008-11-01

459

On the natural convection cooling in HANARO (Hi-flux Advanced Neutron Application Reactor). Experiment and RELAP5/KMRR simulation  

International Nuclear Information System (INIS)

The natural circulation experiments were conducted to confirm the cooling capability and the flow characteristics of the natural convection in the HANARO (Hi-flux Advanced Neutron Application Reactor). The tests were done at the power levels of 2%, 3% and 4% (1.2MW_t_h) of full power. The flow rates and temperatures at various locations of the primary and secondary cooling loops were measured at each power level. The temperature distributions in the chimney and the pool were also obtained. Through tests, the flow paths of the natural circulation and the cooling capability of the reactor were confirmed as designed. In addition, the simulation for the natural circulation tests was made by using RELAP5/KMRR, which was modified from RELAP5/MOD2 for applying to the HANARO conditions. The simulation results show that RELAP5/KMRR gives reasonable predictions for the flow rate and the coolant temperature during natural circulation condition in the HANARO. (author)

460

Numerical Simulation of a Compartment Fire in a Nuclear Power Plant Containment Building  

International Nuclear Information System (INIS)

The current trend towards the increased use of risk assessment in the regulation of nuclear power plants will inevitably result in changes in the analysis of fire protection systems and the methods of analysis. Before fire protection can be regulated on a risk basis, a consensus must be reached on a number of issues. One key issue is what types of computational tools will be allowable for analyzing fire events, and what types of scenarios those tools will be approved for use. Reaching this consensus will require an understanding of the types of computational tools available and their inherent advantages and disadvantages. To aid with this understanding, three different methods of fire simulation are applied to an oil pool fire test in the HDR (Heiss Dampf Reaktor) containment test facility. These methods are a hand calculation, the zone model code CFAST (Consolidated Model of Fire Growth and Smoke Transport), and the computational fluid dynamics code FDS (Fire ...

2002-04-14

461

Nuclear Reactor Sharing Program  

Energy Technology Data Exchange (ETDEWEB)

The Ohio State University Research Reactor (OSURR) is licensed to operate at a maximum power level of 500 kW. A pool-type reactor using flat-plate, low enriched fuel elements, the OSURR provides several experimental facilities including two 6-inch i.d. beam ports, a graphite thermal column, several graphite-isotope-irradiation elements, a pneumatic transfer system (Rabbit), various dry tubes, and a Central Irradiation Facility (CIF). The core arrangement and accessibility facilitates research programs involving material activation or core parameter studies. The OSURR control room is large enough to accommodate laboratory groups which can use control instrumentation for monitoring of experiments. The control instrumentation is relatively simple, without a large amount of duplication. This facilitates opportunities for hands-on experience in reactor operation by nuclear engineering students making reactor parameter measurements. For neutron activation analysis and ...

1994-09-01

462

Mechanisms of radical removal by SO2  

DEFF Research Database (Denmark)

It is well established from experiments in premixed, laminar flames, jet-stirred reactors, flow reactors, and batch reactors that SO2 acts to catalyze hydrogen atom removal at stoichiometric and reducing conditions. However, the commonly accepted mechanism for radical removal, SO2 + H(+M) reversible arrow HOSO(+M), HOSO + H/OH reversible arrow SO2 + H-2/H2O, has been challenged by recent theoretical and experimental results. Based on ab initio calculations for key reactions, we update the kinetic model for this chemistry and re-examine the mechanism of fuel/SO2 interactions. We find that the interaction of SO, with the radical pool is more complex than previously assumed, involving HOSO and SO, as well as, at high temperatures also HSO, SH, and S. The revised mechanism with a high rate constant for H + SO2 recombination and with SO + H2O, rather than SO2 + H-2, as major products of the HOSO + H reaction is in agreement with a range of experimental results from ...

2007-01-01

463

Male mammals respond to a risk of sperm competition conveyed by odours of conspecific males  

Science.gov (United States)

Sperm competition occurs when a female copulates with two or more males and the sperm of those males compete within the female's reproductive tract to fertilize her eggs. The frequent occurrence of sperm competition has forced males of many species to develop different strategies to overcome the sperm of competing males. A prevalent strategy is for males to increase their sperm investment (total number of sperm allocated by a male to a particular female) after detecting a risk of sperm competition. It has been shown that the proportion of sperm that one male contributes to the sperm pool of a female is correlated with the proportion of offspring sired by that male. Therefore, by increasing his sperm investment a male may bias a potential sperm competition in his favour. Here we show that male meadow voles, Microtus pennsylvanicus, increase their sperm investment when they mate in the presence of another male's odours. Such an increase in sperm investment does not ...

2004-09-01

464

Kinetics of nucleotide transport in rat heart mitochondria studied by a rapid filtration technique  

Energy Technology Data Exchange (ETDEWEB)

A rapid filtration technique has been used to measure at room temperature the kinetics of ADP and ATP transport in rat heart mitochondria in the millisecond time range. Transport was stopped by cessation of the nucleotide supply, without the use of a transport inhibitor, thus avoiding any quenching delay. The kinetics of ({sup 14}C)ADP transport in energized mitochondria were apparently monophasic. The rate of transport of ({sup 14}C)ATP in energized mitochondria was 5-10 times lower than that of ({sup 14}C)ADP. Upon uncoupling, the rate of ({sup 14}C)ATP uptake was enhanced, and that of ({sup 14}C)ADP uptake was decreased. However, the two rates did not equalize, indicating that transport was not exclusively electrogenic. Transport of ({sup 14}C)ADP and ({sup 14}C)ATP by resting mitochondria followed biphasic kinetics. Depletion of nucleotides in resting mitochondria resulted in a greater decrease in the extent of the slow phase than of the rapid one. In addition, about half of the ...

1990-10-01

465

Improving T D reliability. How pumped storage can boost network security  

Energy Technology Data Exchange (ETDEWEB)

The key to improving transmission-network security is faster response to contingencies. Now a new breed of pumped-storage plant - designed for ultra-fast response - may soon provide a tool dispatchers can use to improve network security. This type of plant can also substantially increase the effective capacity of existing transmission lines and improve the performance of thermal generating units. The Mt. Hope Waterpower Project, planned for Rockaway Township, NJ, 35 miles west of New York City, lies strategically adjacent to major load centers at the eastern end of the PJM control area and near the interconnection point with the New York Power Pool (NYPP). This location also is in an area deficient in significant generating facilities. Maximum design capacity of the project is 2000 MW, provided by six reversible pump/turbines, each with a nominal 340-MW rating. The upper reservoir, with a surface area of only 60 acres, provides 5000 acre-ft of active storage volume ...

1994-03-01

466

GAMMA GLOBULIN METABOLISM IN RABBITS DURING THE ANAMNESTIC RESPONSE.  

Science.gov (United States)

1. Gamma globulin metabolism and distribution were studied employing rabbit gamma globulin (RGG)I(131) 24 times in 13 control rabbits. Similar studies were performed before and during the ananmestic response in 4 rabbits previously sensitized with a polyvalent pneumococcal vaccine. 2. During the ananmestic response, gamma-globulin levels increased from 1.0 to 6.0 gm/100 ml, and the gamma-globulin pool increased from 0.7 to 4.7 gm/kg. There was no change in the intravascular-extravascular partition of gamma globulin. 3. Gamma globulin degradation increased from 0.06 to 0.33 gm/kg/day during the 28 days of the immunization period while gamma globulin synthesis increased even further to average 0.47 gm/kg/day. Following the attainment of elevated gamma globulin levels the fractional rate of RGG-I(131) turnover increased from 8.0 to 12.5 per cent/day. 4. No differences were noted in the metabolism of homologous or autologous gamma globulin regardless of the allotypic ...

1964-04-01

467

Feasibility study on production of Co-60 in PHWR  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to analyze the safeties and the economics for Co-60 production from Wolsung PHWR and to verify the feasibility on the manufacturing of the final Co-60 source for industrial irradiation. The feasibility of reactor conversion was carried out with KEPCO collaboration. Through the site survey on the experience of Gentililly-2 in Canada, a feasibility of plant conversion, changes in design, equipment and tools for Co-60 production was verified. It was estimated that the reactor conversion would not impose adverse impact on plant safety. For the encapsulation of radiation source and storage of the final products, a modification of concrete hot cell at KAERI was primary concerns. The installation and improvement of facilities are needed to avoid cross contamination and extra radiation exposure. Main items for these are pressure gauge, separated HEPA filter the ceiling separation, extra-shielding and ceiling hoist system. At present, storage ...

2000-05-01

468

Evaluation of selective alveolo-bronchography with Fuji computed radiography and x-ray CT  

International Nuclear Information System (INIS)

Selective alveolo-bronchography (SAB) has been routinely used to evaluate anatomical changes in the bronchiole and its distal air spaces. A narrowing of the bronchiole and abnormal pooling of contrast medium in the destroyed air space are the prime findings. Since the object of radiography is extremely thin, direct magnification radiography is mandatory to obtain radiologic details. However, the problem with this technique is that radiographic quality varies depending upon the size of the patient and the concentration of contrast medium to be introduced in the lung. This study had two goals. One was to improve the image quality of SAB by Fuji Computed Radiography (FCR). FCR provides radiographs with a good contrast and stable density throughout a wide range of exposure factors which occur in the use of SAB. The other goal was to separately evaluate morphological abnormalities in the outer and inner zones of the lung using X-ray CT. This idea was derived from our ...

1986-01-01

469

Effects of C-additions on ecosystem processes in the Serengeti: The role of grazing mammals and implications for global change research  

Energy Technology Data Exchange (ETDEWEB)

Increases in atmospheric CO[sub 2] are predicted to cause an increase in the C:N ratio of plant substrates entering the soil organic matter pool. We experimentally increased soil C:N ratios by adding 40 g C/m[sup 2] as sucrose (metabolic C) or cellulose (structural C) in short-, mid-, and tall-grass plots in the Serengeti Ecosystem, and measured plant productivity, plant nutrient uptake rates, and mineralization rates. Experimental treatments also included fencing to exclude grazing and additions of 40 g N/m[sup 2] as urea to simulate a urine hit from an average-sized ungulate. Productivity was only 60% of controls in C-addition plots, and was similar for sucrose and cellulose. However, this response was not observed in the short-grass site, an area of relatively low rainfall and high fertility. These results support the role of a plant-microbe negative feedback mechanism on plant growth in which increased C to microbes results in increased immobilization, reduced ...

1994-06-01

470

Development, dimensions, reliability and validity of the novel Manchester COPD fatigue scale  

DEFF Research Database (Denmark)

INTRODUCTION: Fatigue is a prominent symptom in chronic obstructive pulmonary disease (COPD) and it has distinctive features; however, there is a need for a robust scale to measure fatigue in COPD. METHODS: At baseline, 122 patients with COPD (forced expiratory volume in 1 s (FEV(1)) 52%, women 38%, mean age 66 years) completed a pilot fatigue scale covering a pool of 57 items and underwent a range of tests, including indicators of mood and a short general fatigue questionnaire. All patients responded to the 57-item scale and it was readministered to a subset of 30 patients. The pilot scale was first subjected to constructive validated shortening steps and then to a principal components analysis. RESULTS: The Manchester COPD fatigue scale (MCFS) consists of 27 items, loading into three dimensions: physical, cognitive and psychosocial fatigue. Internal consistency (Cronbach's alpha = 0.97) and test-retest repeatability (r = 0.97, por=16 scores in the Center for ...

2009-01-01

471

Comparisons between experimental results and numerical simulations for the Sonaco sodium natural convection experiments  

International Nuclear Information System (INIS)

The SONACO experiments are conducted on an electrically heated 37-pin rod bundle, immersed in liquid sodium and contained within a hexagonal wrapper. The rig was designed to investigate natural convection cooling for a geometry representative of fast reactor fuel assemblies. Heat can be removed from the test section in several ways, but in this paper only the axial cooling mode is examined. Above the heated bundle is a plenum, at the top of which is a cooling coil containing a separate, forced sodium flow. Heat transfer from the bundle to this cooling coil is effected by means of buoyancy driven circulatory flow in the sodium, and in the axial cooling mode almost all the heat is removed by the coil. This mode is intended to simulate the natural convection cooling of a blocked fuel assembly by way of thermosyphon coupling to the inner pool. In this paper experimental results are presented, for the temperatures measured under such conditions, and these are compared ...

472

Carbon pools and flux in the forests of Korea  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the estimated the rate of carbon accumulation in the woody biomass and total carbon storage in the forests including trees, soil and litter in Korea. The relevant data come from the Statistical Yearbook of Forestry and major results of the studies on forest biomass in Korea. Most of the forests, which has been denuded or degraded during the 2nd World War and the Korean War, were recovered through ``Reforestation Project(1973-1987)`` and natural regeneration. So, now they are mostly young secondary forests and grow rapidly. Total carbon removal by forests is estimated at 8.1 million tonnes of carbon(MtC) and the carbon emission by commercial harvesting at 0.9 MtC. therefore, the forests in Korea play an essential role as a net carbon sink. The annul net carbon removal is 7.2 MtC and accounts for about 11.0% of total carbon emissions in energy sector of Korea. The carbon storage in the forests is 589.9 MtC, 22.4% of that stored in trees, 64.1% in soil, and 13.5% in ...

1998-04-01

473

Ambient air pollution and congenital heart disease: a register-based study.  

Science.gov (United States)

Maternal exposure to ambient air pollution has increasingly been linked to adverse pregnancy outcomes. The evidence linking this exposure to congenital anomalies is still limited and controversial. This case-control study investigated the association between maternal exposure to ambient particulate matter with aerodynamic diameter less than 10 ?m (PM(10)), sulfur dioxide (SO(2)), nitrogen dioxide, nitric oxide (NO), ozone (O(3)), and carbon monoxide (CO) and the occurrence of congenital heart disease in the population of Northeast England (1993-2003). Each case and control was assigned weekly average (weeks 3-8 of pregnancy) of pollutant levels measured by the closest monitor to the mother's residential postcode. Using exposure as both continuous and categorical variables, logistic regression models were constructed to quantify the adjusted odds ratios of exposure to air pollutants and the occurrence of each outcome group. We found exposure to CO and NO to be associated with ...

2011-02-17

474

A kinetic and microautoradiographic study of sup 14 C-sucrose translocation into developing wheat grains  

Energy Technology Data Exchange (ETDEWEB)

The kinetics of {sup 14}C-photosynthate import by developing wheat grains was followed after pulse-labeling the flag leaf with {sup 14}CO{sub 2}. Samples were collected from four successive points along the transport pathway to and within the grain: exuding aphid stylets on the peduncle, exuding grain pedicels, the grain crease tissues, and the liquid contents of the endosperm cavity. In addition, microautoradiographs were prepared of the grain crease tissues during movement of the {sup 14}C pulse into the grain. At all times, sucrose accounted for 93 to 97% of the total {sup 14}C present at all four sampling sites. The main features of the {sup 14}C kinetics could be accounted for by a simple compartmental model consisting of sucrose pools in series. Microautoradiographs of the crease tissues showed fairly uniform labeling of vascular parenchyma at all times, with a sharp gradient in labeling across the chalaza to the nucellus. Thus the principal resistance to ...

1991-05-01

475

Assessment and Forecasting Natural Gas Reserve Appreciation in the Gulf Coast Basin  

Energy Technology Data Exchange (ETDEWEB)

Reserve appreciation, also called reserve growth, is the increase in the estimated ultimate recovery (the sum of year end reserves and cumulative production) from fields subsequent to discovery from extensions, infield drilling, improved recovery of in-place resources, new pools, and intrapool completions. In recent years, reserve appreciation has become a major component of total U.S. annual natural gas reserve additions. Over the past 15 years, reserve appreciation has accounted for more than 80 percent of all annual natural gas reserve additions in the U.S. lower 48 states (Figure 1). The rise of natural gas reserve appreciation basically came with the judgment that reservoirs were much more geologically complex than generally thought, and they hold substantial quantities of natural gas in conventionally movable states that are not recovered by typical well spacing and vertical completion practices. Considerable evidence indicates that many reservoirs show ...

1997-10-01

476

Water demand management in areas of ground water over-exploitation  

Environmental Research Database

SummaryIntended Outputs: Identification and evaluation, using participatory approaches, of demand management options:*Technical*Allocative and market based*Impact on target beneficiariesSupporting measures required when introducing water demand management options above:*Extension services & training*Water licences/rights*Institutional changes*Legal measures and regulation*Education*Support in diversifying to less water demanding activities*S [continued...]ObjectivesIdentification of the most appropriate demand management strategies for ground water abstraction, where aquifiers are being over-exploited, ensuring sustainable livelihoods of the vulnerable and poor are safeguarded. Poverty reduction strategies for areas where groundwater is being over-exploited.DescriptionProject Background: Groundwater is the principal source of both irrigation and domestic water supplies in many ...

2006-01-15

477

Water consumption during solid state sodium borohydride hydrolysis  

Energy Technology Data Exchange (ETDEWEB)

In this paper nickel acetate catalyzed sodium borohydride cartridges have been prepared and hydrolyzed with water for hydrogen production. Two technological solutions have been tested to increase the overall hydrogen yield, namely a porous water diffuser and a hydrophobic membrane. The first was used to improve water diffusion inside the hydride while the second to confine water inside the cartridge. The generated hydrogen flow showed a very reproducible behavior. Hydrogen promptly evolved just after water was pumped into the cartridge. After some initial peaks, a constant hydrogen flow has been recorded for the whole reaction time. The constant flow was related to the presence of the porous diffuser. The use of a hydrophobic membrane to confine the water inside the cartridge allowed to increase the overall hydrogen yield: about 6 water ...

2010-11-15

478

Phytoplankton primary production in a eutrophic cooling water pond  

Energy Technology Data Exchange (ETDEWEB)

The effect of longer ice-free periods on the seasonal variation and total annual values of phytoplankton primary production was considered along with the efficiency and productivity of the phytoplankton communities at different water temperatures by constant light. The studied pond, Vasikkalampi, is located in the town Jvyaskyla in central Finland. The pond is slightly eutrophic and its water is used for cooling purposes by a 35 MW thermal powerplant. The cooling water is taken in the middle of the pond and it returns as heated effluent to the northern part, near the surface, about 100 m from the intake pipe. This circulation and warming of the water keeps the pond open throughout the year except during the coldest weeks in the winter when some parts freeze over. The increase of the water temperature was not sufficient to be optimal for photosynthesis in the spring. The ...

1984-01-01

479

Natural radionuclides in drinking water in Argentina  

International Nuclear Information System (INIS)

As part of the national survey to evaluate natural radioactivity in the environment, concentration levels of natural uranium and "2"2"6Ra have been analyzed in over 300 drinking water samples taken from different locations in Argentina. "2"2"6Ra was determined by "2"2"2Rn emanation and liquid scintillation counting, and natural uranium by a fluorimetric procedure. Values ranging from 0.03 to 24 #mu#g.l"-"1 of natural uranium and from 0.06 to 50 #mu#g.l"-"1, were measured on drinking water samples taken from tap water systems and private wells, respectively. Concentrations up to 15 mBq.l"-"1 and to 22 mBq.l"-"1 of "2"2"6Ra were found in drinking water samples taken from tap water systems and private wells, respectively. These values are compared with the reference values accepted for drinking water. Based on the water intake rate, the age ...

2000-05-01

480

Climate change and water resources in Britain  

International Nuclear Information System (INIS)

This paper explores the potential implications of climate change for the use and management of water resources in Britain. It is based on a review of simulations of changes in river flows, groundwater recharge and river water quality. These simulations imply, under feasible climate change scenarios, that annual, winter and summer runoff will decrease in southern Britain, groundwater recharge will be reduced and that water quality - as characterised by nitrate concentrations and dissolved oxygen contents - will deteriorate. In northern Britain, river flows are likely to increase throughout the year, particularly in winter. Climate change may lead to increased demands for water, over and above that increase which is forecast for non-climatic reasons, primarily due to increased use for garden watering. These increased pressures on the water resource base will ...

1998-05-01

481

Radon concentrations in well water in Sichuan Province, China  

International Nuclear Information System (INIS)

There are 110 million people in Sichuan Province, China. Although most of the people in cities of Sichuan use river water, which contains low levels of radon, as potable water, people in countryside and in some communities of big cities still use well water as domestic consumption. This paper reports the radon concentrations in well water investigated in four cities, i.e. Chengdu, Chongqing, Leshan and Leijiang in Sichuan Province. Of the 80 wells investigated, the radon concentrations range from 3.5 to 181.6 KBqm"-"3. Of the four cities, Chongqing has the highest well water radon concentration with the average 49.6 #+-# 54.1 KBqm"-"3 and the greatest variation. The investigation in four cities showed that the radon concentrations in well water are much higher than that in tap-water. In Chongqing where there are complex geological ...

482

EDI as a Treatment Module in Recycling Spent Rinse Waters  

Energy Technology Data Exchange (ETDEWEB)

Recycling of the spent rinse water discharged from the wet benches commonly used in semiconductor processing is one tactic for responding to the targets for water usage published in the 1997 National Technology Roadmap for Semiconductors (NTRS). Not only does the NTRS list a target that dramatically reduces total water usage/unit area of silicon manufactured by the industry in the future but for the years 2003 and beyond, the NTRS actually touts goals which would have semiconductor manufacturers drawing less water from a regional water supply per unit area of silicon manufactured than the quantity of ultrapure water (UPW) used in the production of that same silicon. Achieving this latter NTRS target strongly implies more widespread recycling of spent rinse waters at semiconductor manufacturing sites. In spite of the fact that, by most ...

1999-08-11

483

Water consumption of a six-year-old river red gum plantation in the Southern Zagros Mountains, Iran  

British Library Electronic Table of Contents (United Kingdom)

Water is the most important limiting factor in the development of arid environments; therefore, optimization of water use is a necessity in desert reclamation projects. Evapotranspiration of a 6-year-old river red gum (Eucalyptus camaldulensis Dehnh.) plantation, located in a sedimentation basin of an artificial recharge of the Gareh Bygone Plain groundwater system in Iran?s southern Zagros Mountains, was studied during a 7-month period. A neutron moisture probe was used to monitor soil water changes in the root zone. Soil water depletion following rapid drainage for blocks receiving relatively high, medium and low volumes of floodwater were 809.6, 312.4, and 203.1 mm, respectively, for a 150-day period. Soil water potential during most of the study period was below ?1.5 MPa. This study pr...

2007-01-01

484

The role of water and oxygen impurities on ozone production in a negative corona discharge of CO_2  

International Nuclear Information System (INIS)

The production of ozone in a negative corona discharge fed by carbon dioxide with embedded traces of oxygen and water has been studied. The presence of traces of oxygen in both pure and dry CO_2 leads to an increase in nascent ozone concentrations. In contrast, traces of water vapour (0-800 ppm) are shown to rapidly suppress ozone concentrations with the largest decreases being observed at lowest gas pressures in the discharge (300 Torr). The presence of water vapour did not considerably affect the electrical properties of negative dc corona suggesting that a chemical process is responsible for the ozone loss. We have shown that the addition of water up to a concentration of 1500 ppm has only a marginal effect on the processes of ozone formation but the catalytic cycle of ozone destruction involving OH radicals can be the reason for observed decrease in the total ozone concentration with increasing ...

2007-11-07

485

Source and mobility of minor and trace elements in a volcanic aquifer system: Mt. Vulture (southern Italy)  

British Library Electronic Table of Contents (United Kingdom)

In this paper we provide a geochemical investigation on 34 groundwater samples in the Mt. Vulture volcanic aquifer representing one of the most important groundwater resources of the southern Italy pumped for drinking and irrigation supply. The present study includes the first data on the abundance and mobility of minor and trace elements and the thermodynamic considerations on water-rock interaction processes in order to evaluate the conditions of alkali basalt weathering by waters enriched in magma-derived CO2. The results highlight the occurrence of two hydrofacies: bicarbonate alkaline-earth and alkaline waters deriving from low-temperature leaching of volcanic rocks of Mt. Vulture, and bicarbonate-sulfate-alkaline waters (high-salinity waters) related to prolonged water circulation in...

2011-01-01

486

Presence of pathogenic microorganisms in power-plant cooling waters. Report for October 1, 1979-September 30, 1981  

Energy Technology Data Exchange (ETDEWEB)

Cooling waters from eleven geographically disparate power plants were tested for the presence of Naegleria fowleri and Legionella pneumophila (LDB). Control source waters for each plant were also tested for these pathogens. Water from two of the eleven plants contained pathogenic Naegleria, and infectious Legionella were found in seven of the test sites. Pathogenic Naegleria were not found in control waters, but infectious Legionella were found in five of the eleven control source water sites. Concentrations of nitrite, sulfate, and total organic carbon correlated with the concentrations of LDB. A new species of Legionella was isolated from one of the test sites. In laboratory tests, both Acanthamoeba and Naegleria were capable of supporting the growth of Legionella pneumophila.

1982-10-01

487

On Sensitivity of Spectral Radiative Fluxes to Atmospheric Water Vapor in the 940 nm Region (Numerical Simulation)  

Energy Technology Data Exchange (ETDEWEB)

Water vapor is well known to be a critical component in many aspects of atmospheric research, such as radiative transfer and cloud and aerosol processes. This requires both improved measurements of the columnar water vapor and its profiles in the atmosphere in a wide range of conditions, and adjustment of water vapor parameterizations in radiation codes including the perfection of spectroscopic parameters. In this paper we will present the results of comparison of our calculations and downward solar fluxes measured with Rotating Shadowband Spectroradiometer under conditions of horizontally homogeneous clouds. We also will discuss the sensitivity of atmospheric radiation characteristics to variations of water vapor in the band 940 nm: these results may be useful for development of new methods of retrieval of the total column water vapor content (WVC) in the atmosphere from data of ...

2005-03-18

488

Non-catalytic and catalytic wet air oxidation of pharmaceuticals in ultra-pure and natural waters  

British Library Electronic Table of Contents (United Kingdom)

A wet air oxidation (WAO) process was applied to four selected pharmaceuticals (metoprolol, naproxen, amoxicillin, and phenacetin) individually dissolved in ultra-pure water, varying the temperature and oxygen pressure. Due to the moderate (amoxicillin) or low (metoprolol, naproxen, and phenacetin) efficiency found in the oxidation of these pollutants, a catalytic wet air oxidation (CWAO) process was then tested using a platinum catalyst supported on multi-walled carbon nanotubes (CNT). In this CWAO process, the pharmaceuticals were dissolved together in ultra-pure water and in four natural water matrices-a reservoir water, a groundwater, and two waters from different municipal wastewater treatment plants. On the basis of the measurements of their removals, a discussion is given of the inf...

2011-01-01

489

Nomographs for the rapid prediction of salt quality and influent water quality impacts on hardness leakage in steamflood water  

Energy Technology Data Exchange (ETDEWEB)

Counter-current regeneration of 2-stage sodium zeolite softeners has been employed in reducing hardness leakage level of steamflooding water to less than 1 ppm when raw water contains as much as 5,000 ppm of the total dissolved solids. Hardness leakage is caused by sodium displacement of calcium and magnesium from the bottom of the exchanger bed. This study presents nomographs providing for rapid calculations to be made, for which a convenient operational mode does not already exist. The nomographs relate the hardness leakage as a function of salt quality and influent water quality and present solutions for predicting the leakage level, salt quality requirement or the treatability of raw water required for steamflooding projects.

1982-08-01

490

Energy saving self-powered industrial dehumidifier  

Energy Technology Data Exchange (ETDEWEB)

An energy saving self-powered industrial dehumidifier for use in a building having a tap water conduit leading from a source of supply to utilization points is described comprising: a dehumidifying apparatus positioned in a stream of air to be dehumidified in the building. The dehumidifying apparatus comprising conduit means for diverting at least a portion of a relatively continuously moving stream of tap water from the tap water conduit through a heat exchanger positioned in a stream of air and returning the diverted portion to the tap water stream upstream of the utilization points. Water vapor in the stream of air will condense onto the heat exchanger when the tap water has a temperature below a dew point temperature of the air stream, thereby dehumidifying the air stream.

1988-07-26

491

Elucidating two-phase transport in a polymer electrolyte fuel cell, Part 1: Characterizing flow regimes with a dimensionless group  

British Library Electronic Table of Contents (United Kingdom)

This paper explores the through-/in-plane characteristics of water transport in the cathode gas diffusion layer (GDL) of a polymer electrolyte fuel cell (PEFC). Theoretical analysis is performed on the non-isothermal two-phase flow under flow channels. A dimensionless group Da (Damkohler number for PEFC operation), defined as the ratio of water generation rate to water vapor-phase removal rate, is formulated to characterize the flow regimes in a PEFC. This group, lumping geometrical parameters and physical properties, compares the water vapor-phase removal capability (via water diffusion and holding capacity) with the rate of water production by the oxygen reduction reaction. We find that this dimensionless group can be used to characterize the non-isothermal, two-phase phenomena: when Da&...

2011-01-01

492

Efficacy of three commercially available ballast water biocides against vegetative microalgae, dinoflagellate cysts and bacteria  

British Library Electronic Table of Contents (United Kingdom)

One proposed solution to the problem of ballast-mediated aquatic invasions involves chemically treating ballast water to kill key target organisms. Here, we examine the efficacy of three commercially available ballast water biocides using vegetative microalgae, dinoflagellate resting cysts and bacteria as test organisms. Chemicals tested were the ballast water biocides SeaKleen and Peraclean Ocean, and the chlorine dioxide biocide Vibrex. Results demonstrate that the applicability of each of the three chemical biocides as a routine ballast water treatment is limited by factors such as cost, biological effectiveness and possible residual toxicity of the discharged ballast water (assessed on the basis of impact on motility of vegetative marine microalgae). Of the three biocides tested, Perac...

2007-01-01

493

Comparison of levels of trace elements extracted from fly ash and levels found in effluent waters from a coal-fired power plant  

Science.gov (United States)

Trace elements were extracted from a coal-fired power plant electrostatic precipitator ash with nitric acid, hydrochloric acid, citric acid, redistilled water, and ammonium hydroxide as extractants. Effluent waters at this plant were sampled to assess the elevation of trace element concentrations compared with intake waters. The results showed a positive correlation between those elements most extractable by water (B, F, Mo, and Se) or acid (As, B, Cd, F, Mo, and Se) and those elements most elevated in effluent waters (As, B, F, Mo, and Se).

1977-10-01

494

Model experiment on change of seismic properties of a fracture caused by injecting/draining water; Chusui/haisui ni yoru kison kiretsu no dansei denpa tokusei no henka ni kansuru model jikken  

Energy Technology Data Exchange (ETDEWEB)

Effect of water injection/draining on elastic waves penetrating through cracks is examined by measuring elastic waves before, during, and after the injection/draining of water into/from cracks in presence in granite. Two blocks of rock, with their crack-containing surfaces in contact with each other, are placed in a vessel, and water injection/draining is done through a hole on a vessel bottom side so that water will penetrate into the cracks. When the blocks are dry, there is almost no contact between the cracks, and so no crack penetrating waves are observed. Crack penetrating waves are produced when water is injected, and the position of the receiver sensing the penetrating waves changes as the water level rises. When the water level is lowered from the high water level, the waveform changes again as the level ...

1997-05-27

495

Induction of mortality and malformation in Xenopus laevis embryos by water sources associated with field frog deformities.  

UK PubMed Central (United Kingdom)

Water samples from several ponds in Minnesota were evaluated for their capacity to induce malformations in embryos of Xenopus laevis. The FETAX assay was used to assess the occurrence of malformations...Full Text Available

1998-12-01

496

Hybrid solution and pump-storage optimization in water supply system efficiency: A case study  

International Nuclear Information System (INIS)

Environmental targets and saving energy have become ones of the world main concerns over the last years and it will increase and become more important in a near future. The world population growth rate is the major factor contributing for the increase in global pollution and energy and water consumption. In 2005, the world population was approximately 6.5 billion and this number is expected to reach 9 billion by 2050 [United Nations, 2008. (www.un.org), accessed on July]. Water supply systems use energy for pumping water, so new strategies must be developed and implemented in order to reduce this consumption. In addition, if there is excess of hydraulic energy in a water system, some type of water power generation can be implemented. This paper presents an optimization model that determines the best hourly operation for 1 day, according to the electricity tariff, for a pumped ...

2008-11-01

497

A water calorimeter for high energy x-rays and electrons  

CERN Document Server

The current primary standards at NPL for the measurement of absorbed dose to water in high energy photon and electron beams are graphite calorimeters. However, the quantity of interest in radiation dosimetry is absorbed dose to water. Therefore, a new absorbed dose to water standard based on water calorimetry has been developed for use in high energy photon and electron beams. The calorimeter operates at 4 deg C, with temperature control being provided by liquid cooling. The sealed glass inner vessel of the calorimeter was designed to minimise the effect of non-water materials on the measurement of absorbed dose. The temperature sensing thermistor probes were designed and constructed so that glass is the only material in contact with high purity water inside the vessel. Initial measurements of absorbed dose to water made in 6, 10, and 19 MV ...

2000-01-01

498

A Feasibility Study to Lower Steam Generator Low Water Level Trip Setpoint to Reduce Unnecessary Scram Frequency for KORI 3,4 Plant  

Energy Technology Data Exchange (ETDEWEB)

The steam generator low water level trip setpoint of KORI NPP units 3 and 4(KNU 3 and 4), three-loop Westinghouse pressurized water reactor, is higher than that of OPR1000. In addition, steam generator downcomer water level in KNU 3 and 4 could fluctuate easily during a transient because of smaller downcomer water inventory, compared to the total water inventory in the steam generator. Due to these reasons, there is a higher possibility of unnecessary reactor trips caused by the steam generator low-low water level in KNU 3 and 4. Its operating history shows that most of reactor trips were caused by steam generator low-low level reactor trip signal. Such reactor trips, especially unnecessary ones, result in time and economic losses. In this paper, a feasibility study was performed to reduce unnecessary reactor trip by changing steam generator low-low ...

2008-10-15

499

A Feasibility Study to Lower Steam Generator Low Water Level Trip Setpoint to Reduce Unnecessary Scram Frequency for KORI 3,4 Plant  

International Nuclear Information System (INIS)

The steam generator low water level trip setpoint of KORI NPP units 3 and 4(KNU 3 and 4), three-loop Westinghouse pressurized water reactor, is higher than that of OPR1000. In addition, steam generator downcomer water level in KNU 3 and 4 could fluctuate easily during a transient because of smaller downcomer water inventory, compared to the total water inventory in the steam generator. Due to these reasons, there is a higher possibility of unnecessary reactor trips caused by the steam generator low-low water level in KNU 3 and 4. Its operating history shows that most of reactor trips were caused by steam generator low-low level reactor trip signal. Such reactor trips, especially unnecessary ones, result in time and economic losses. In this paper, a feasibility study was performed to reduce unnecessary reactor trip by changing steam generator low-low ...

2008-10-01