Development of a geothermal heat pump. Final report
Energy Technology Data Exchange (ETDEWEB)
In the development of a geothermal heat pump a water source heat pump was connected to a 1-1/2'' water line, 2200' long, buried in an endless loop 10' deep. The system is closed, circulating the same water continuously through the heat pump back to the field again. This water line 10' deep is the geothermal heat source. No matter how cold the air temperature gets on a winter day the water temperature to the heat pump will always be above 45/sup 0/F. This system has efficiently heated our house the past year using no supplemental heat.
1981-11-02
Rural residential application of geothermal heat pump. Progress report
Energy Technology Data Exchange (ETDEWEB)
The installation and performance of a water source heat pump in Minnesota are discussed. The operating cost was found to be higher than expected. (MHR)
1981-07-20
Binary heat pump system. Binary heat pump system
Energy Technology Data Exchange (ETDEWEB)
This technical report describes an outline, features, total energy efficiency, and specifications of binary heat pump system. A closed circuit distributed water heat source heat pump method is employed in the binary heat pump system. Since the circulating water, which is adjusted at a constant temperature, is used as the heat source of the indoor unit, a stable performance can be obtained regardless of outside atmospheric temperature. The binary heat pump system is mainly composed of a center heat pump unit, indoor heat pump unit, heat source water pipes, and circulating pump. The center ...
1993-11-30
Energy Technology Data Exchange (ETDEWEB)
Ground water ranging in temperature from only 38/sup 0/ to 140/sup 0/F can supply a considerable amount of heat energy when couple with a geothermal or ground-water heat pump. The heat pump's method of operation is examined as well as its performance characteristics. (MHR)
1982-12-01
Underground Mine Water Heating and Cooling Using Geothermal Heat Pump Systems
Energy Technology Data Exchange (ETDEWEB)
In many regions of the world, flooded mines are a potentially cost-effective option for heating and cooling using geothermal heat pump systems. For example, a single coal seam in Pennsylvania, West Virginia, and Ohio contains 5.1 x 1012 L of water. The growing volume of water discharging from this one coal seam totals 380,000 L/min, which could theoretically heat and cool 20,000 homes. Using the water stored in the mines would conservatively extend this option to an order of magnitude more sites. Based on current energy prices, geothermal heat pump systems using mine water could reduce annual costs for heating by 67% and cooling by 50% over conventional methods (natural gas or heating oil and standard air conditioning).
2006-03-01
Rural residential application of geothermal heat pump. Final grant report
Energy Technology Data Exchange (ETDEWEB)
A project to demonstrate residential heating and cooling with a well-water source heat pump is documented. The system is schematically illustrated and described, and project experience is discussed. The system is capable of using source water as cool as 40/sup 0/F. Project expenses are accounted for. (LEW)
1982-07-30
The thermal response of an infinite line of open loop wells for ground coupled heat pump systems
British Library Electronic Table of Contents (United Kingdom)
Ground thermal energy storage is a means of storing thermal energy underground during the summer and utilizing it during the winter. The main use of such a technology is in the heating, ventilating and air conditioning sector where the ground provides a stable temperature reservoir for a heat pump system. Heat pumps are mechanical systems that provide heating to a space in the winter, and cooling in the summer. They are increasingly popular because the same system provides both heating modes, depending on the direction of the cycle upon which they operate. The stable temperature reservoir allows the heat pump system to run at a higher efficiency. Thermal energy is transmitted to and from the ground by circulation of water through standing column geothermal wells. In commercial ...
2011-01-01
International Nuclear Information System (INIS)
Purpose: To obtain stabilized operation by preventing over heat in emergency cooling pumps upon accidents of flow regulators. Constitution: A pressure suppression chamber pool and a pressure vessel are communicated to each other with a pipeway and the water in the suppression pool is charged by a charging pump to the pipeway. The pipeway is interposed with an emergency cooling pump so as to feed water in the pipeway to the pressure vessel and a water source and the emergency cooling pumps are connected by way of a closed pipeway. Further, the closed pipeway and the pipeway interposed with the charging pump are communicated to each other by way of a connecting pipeway, to which are interposed an instrument for detecting the increase in the temperature of the emergency cooling ...
Energy Technology Data Exchange (ETDEWEB)
This research report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that examined the feasibility of setting up 'MINERGIE' low-energy-consumption module standards for the production of heat in small residential buildings. The aims of the standards and the basic idea behind the MINERGIE-modules are discussed. The concepts of the modules for heat pumps and wood-fired heating systems and their combination with solar installations are examined, as are their areas of application. The requirements placed on the modules are listed. System concepts, including simple schematics for typical installations, are presented for wood-log, wood-chippings and pellets-fired systems as well as for ground-loop and air-water heat pump systems as well as their solar-aided counterparts. The results of cost-benefit ...
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
The merits of single stage absorption heat pumps coupled to simple distillation for effluent treatment are discussed. An experimental integrated absorption heat pump effluent purification system (IAHPEPS) was built and operated with water-lithium bromide as a working mixture. This unit has been used to raise the temperature and hence, the vapour pressure of the impure water contained in one vessel, to the point where pure water vapour will distil from impure effluent solution (tap water or brine) and condense in a second vessel used to collect pure water. Pure effluent production rates of between 0.5 and 4.3 kg h{sup -1} were obtained. The actual coefficient of performance (COP{sub A}) and the heat pump effectiveness varied from 1.1 to 1.4 and 0.58 to 0.72, ...
1999-05-01
Energy Technology Data Exchange (ETDEWEB)
The main objective of the present study is twofold: (i) to analyze thermal loads of the geothermally and passively heated solar greenhouses; and (ii) to investigate wind energy utilization in greenhouse heating which is modeled as a hybrid solar assisted geothermal heat pump and a small wind turbine system which is separately installed in the Solar Energy Institute of Ege University, Izmir, Turkey. The study shows 3.13% of the total yearly electricity energy consumption of the modeled system (3568 kWh) or 12.53% of the total yearly electricity energy consumptions of secondary water pumping, brine pumping, and fan coil (892 kWh) can be met by using small wind turbine system (SWTS) theoretically. According to this result, modeled passive solar pre heating technique and combined with geothermal heat ...
2010-01-15
Energy Technology Data Exchange (ETDEWEB)
The heating system of the `Centre integre de mecanique industrielle de la Chaudiere`, in Saint-Georges, Quebec, is based on a solar wall and a geothermal heat pump with a glycol/water mixture circulating in 44 wells that are 100 m deep. With installation costs below $25 per sq.m, more than 85 per cent of the heating needs of the 9500 sq.m centre were supplied by geothermal power. The geothermal heat pump is composed of a well field and two 211-kW cooling units, each equipped with four coiled compressors. In winter, heat is pumped from the earth and in summer, a heat exchanger with control valves allows to heat to be dumped back into the earth. The monitoring and simulation of the system proved its efficiency, considering the climatic conditions in Quebec. The ...
1996-12-01
Energy Technology Data Exchange (ETDEWEB)
Petropavlovsk-Kamchatky (P-K) city in Kamchatka, Russia is operating hot-water district heating using heavy oil boilers and waste hot water of thermal power plants as heat sources. Feasibility study was made on district heating using natural geothermal hot water and/or geothermal heat pump systems as heat sources of hot water supply for reduction of greenhouse effect gas emission. Among 3 areas including geothermal hot water, use of hot water in K area was impossible because of lower temperature and less spring water. Use of hot water in P and UP areas was impossible as primary hot water because of temperature drop to 64 degrees C during hot water supply ...
1999-05-01
International Nuclear Information System (INIS)
At a military base in the Southeastern US, an energy services company (ESCO) has proposed to retrofit more than 1,000 family residences with geothermal heat pumps as part of an energy savings performance contract (ESPC). Each residence is to have one heat pump with its own ground heat exchanger consisting of two or more vertical bores. A design firm hired by the ESCO sized the heat pumps to meet peak cooling loads, and sized the borefields to limit the maximum entering water temperature (EWT) to the heat pumps to 95 F (35 C). Because there is some disagreement in the geothermal heat pump industry over the peak temperature to be used for design (some designers and design manuals recommend temperatures as low as 85 F[29 C], while equipment ...
A cryocondensation pump for the DIII-D Advanced Divertor Program
Energy Technology Data Exchange (ETDEWEB)
A cryocondensation pump was designed for the baffle chamber of General Atomics DIII-D tokamak and will be installed in the fall of 1992. The purpose of the pump is to study plasma density control by pumping the divertor. The pump is toroidally continuous, approximately 10 m long and located in the lower outer corner of the vacuum chamber of the machine. It consists of a 1 m{sup 2} liquid helium-cooled surface surrounded by a liquid nitrogen-cooled shield to limit the heat load on the helium-cooled surface. The liquid nitrogen-cooled surface is surrounded by a radiation/particle shield to prevent energetic particles from impacting and releasing condensed water molecules. A thermal enhancement coating was applied to the nitrogen shell to lower the maximum temperature of the shell. The coating is non-continuous to keep the toroidal electrical resistance high. The ...
1992-03-01
Energy Technology Data Exchange (ETDEWEB)
A geothermal heat pump-assisted heating system is introduced into Changchun City and a survey is conducted to determine if the system may be popularized in this extremely cold region located in the northeastern part of China. In concrete terms, the hot water that circulates through the office building of Changchun Ground Heat Development Co., Ltd., is switched to hot water prepared by a geothermal heat pump. The test continued from December 2000 to March 2001. It is then concluded that heating by geothermal heat pumps will be fully serviceable to Changchun City. Implemented are (1) the shift from the coal fired boiler system to a geothermal heat pump system comprising 16 subterranean heat ...
2001-03-01
...limited to, emission control devices, pumps, filters, muck cookers, stills, solvent tanks, solvent containers, water separators...facility that meets the conditions of ยง 63.320(g). Muck cooker means a device for heating perchloroethylene-laden...
2009-07-01
Technical-economic aspects of the utilization of geothermal waters
International Nuclear Information System (INIS)
A brief description is given of the physico-chemical parameters characterized a hot water geothermal reservoir and of its exploitation by means of single or coupled (doublet) wells. The technical aspects of geothermal heat to the users is then discussed, beginning with corrosion of materials caused by seven main agents: oxygen, hydrogen sulphide, carbon dioxide, ammonia, hydrogen, sulphates and chlorides. A brief mention is made of scaling due to calcium carbonate, silica and calcium sulphates. The basic components of a geothermal plant for non-electric uses are then discussed: production pumps, surface pipelines, heat exchangers, heat pumps and reinjection pumps. The advantages and disadvantages of the different equipment and materials used in the geothermal sector are also presented. A list is also given of the criteria used in the energy ...
Coupling of geothermal heat pumps with thermal solar collectors
Energy Technology Data Exchange (ETDEWEB)
The study discussed relates to the design and development of a process consisting of combining a reversible geothermal heat pump with thermal solar collectors for building heating and cooling and the production of domestic hot water. The proposed process, called GEOSOL, has been installed in a 180 m{sup 2} private residence in 2004. This installation is the subject of long-term experimental follow-up to analyse the energy-related behavior of the installation at all times of the year. In addition, different configurations of this combined system (geothermal heat pump and thermal solar collectors) have been defined and will be simulated numerically using TRNSYS software. A comparative analysis of these different alternative versions will be conducted to determine the best configuration(s) of the GEOSOL process in terms of energy, economical and environmental ...
2007-07-15
Horizontal ground coupled heat pump: Thermal-economic modeling and optimization
Energy Technology Data Exchange (ETDEWEB)
The modeling and optimizing processes of a Ground Coupled Heat Pump (GCHP) with closed Horizontal Ground Heat eXchanger (HGHX) are presented in this paper. After thermal modeling of GCHP including HGHX, the optimum design parameters of the system were estimated by minimizing a defined objective function (total of investment and operation costs) subject to a list of constraints. This procedure was performed applying Genetic Algorithm technique. For given heating/cooling loads and various climatic conditions, the optimum values of saturated temperature/pressure of condenser and evaporator as well as inlet and outlet temperatures of the water source in cooling and heating modes were predicted. Then, for our case study, the design parameters as well as the configuration of HGHX were obtained. Furthermore, the sensitivity analysis of change in the total annual cost ...
2010-12-15
Flooded Underground Coal Mines: A Significant Source of Inexpensive Geothermal Energy
Energy Technology Data Exchange (ETDEWEB)
Many mining regions in the United States contain extensive areas of flooded underground mines. The water within these mines represents a significant and widespread opportunity for extracting low-grade, geothermal energy. Based on current energy prices, geothermal heat pump systems using mine water could reduce the annual costs for heating to over 70 percent compared to conventional heating methods (natural gas or heating oil). These same systems could reduce annual cooling costs by up to 50 percent over standard air conditioning in many areas of the country. (Formatted full-text version is released by permission of publisher)
2007-04-01
Influence of two systematic parameters on the geothermal heat pump system operation
Energy Technology Data Exchange (ETDEWEB)
In order to match the output capacity of a geothermal heat pump system (GHPS) with the actual load requirement, research has been carried out in finding the influence of two systematic parameters, the water flow rate inside the condenser and the compressor input frequency on the GHPS operation. Experiments are done on a small-scale GHPS at the water flow rate ranging from 0.054 kg/s to 0.174 kg/s and the frequency from 30 Hz to 55 Hz. The analysis of the experimental data reveals the relationships among the compressor frequency, the water flow rate and other important parameters such as coefficient of performance (COP), heat capacity and compressor power input. The conclusions in the paper can serve as some guidance to the load adjustment of GHPS. (author)
2003-01-01
In the Loop : A look at Manitoba's geothermal heat pump industry
International Nuclear Information System (INIS)
This booklet outlines the position of Manitoba's heat pump market with the objective of promoting the widespread use of geothermal heat pumps in the province. It makes reference to the size of the market, customer satisfaction with heat pumps, and opinion of key players in the industry regarding the heat pump market. The information in this booklet is drawn on market research and lessons learned in Europe and the United States. In October 2001, a group of key stakeholders in Manitoba's heat pump market attended an industry working meeting to address the issues of market barriers, market enablers and market hot buttons. Market barriers include the high cost of geothermal heat pumps, lack of consumer awareness, lack of consistent standards, ...
Energy Technology Data Exchange (ETDEWEB)
The very low-pressure expansion tank of the title invention is connected to the water in the central heating installation via a connecting pipe with a pump and valves on one side, and on the other side the tank is connected via a connecting pipe with valve to the tap water mains, so that the supply of water can be regulated automatically. Within the expansion tank contact with the outside air is not possible because of an air/water separating floater. By means of recording and control (also remote) of the contents of the expansion tank, the installation pressure and the quantity of supplied water from the expansion tank and the tap water mains, failures and water damage are prevented. 4 figs.
1995-09-01
Cooling facility for reactor container
International Nuclear Information System (INIS)
Cooling water is sprayed on the outer surface of an upper portion of a container, and a pool is formed by the cooling water flowing down while cooling the container. Further, the cooling water stored in the cooling water pool is recycled by a pump for spraying the cooling water on the outer surface of the upper portion of the container. Sufficient amount of cooling water is supplied for spraying the cooling water to the outer surface of the upper portion of the container so that the outer surface of the container is free from drying and a liquid membrane is formed on the entire surface. The amount of the cooling water is made greater than that of the cooling water evaporated when the entire amount of the heat generate in the reactor core of the reactor is ...
1993-05-07
Radisson community heating systems: technical and economic comparison of options. Final report
Energy Technology Data Exchange (ETDEWEB)
The study reported was conducted to evaluate water source community heat pump systems for possible installation to serve a number of homes which are to be constructed in the northeast section of Radisson, New York. Although specific sites and facilities have been evaluated, it is the intent of this study to be site specific only to the extent of climatic conditions. In other words, the results of this study should apply to any area with similar climate.
1981-12-01
Guide to UK renewable energy companies 2001. 6. ed.
International Nuclear Information System (INIS)
This 2001 edition of the guide to UK renewable companies and equipment and service providers presents summaries of the different industry sectors covering wind power, photovoltaics, solar water heating, geothermal heat pump, hydroelectric power, marine current and wave technology, bioenergy, power generation from landfill gas, energy from waste, and cogeneration. A UK company classification listing and index is provided along with listing of UK organisations and companies and an index of advertisers.
Telephone exchange Feutersoey - first pilot plant of the PTT with solar collectors
Energy Technology Data Exchange (ETDEWEB)
In the course of this year six local exchange offices with alternative heating and hot water plants were started up in Switzerland. They are all of the same building type, designed for not more than 1000 telephone subscribers and for the same architectural conditions. However, the buildings are situated in different areas of the country and are thus subject to different environmental conditions. Solar collectors supplemented by electricity boilers are fitted to two of these objects. Heat pumps are operated in two other exchange offices while the last two are equipped with electric heating devices. For purposes of comparison two new test plants of the same size with oil heating devices are set up.
1981-01-01
The importance of axial effects for borehole design of geothermal heat-pump systems
Energy Technology Data Exchange (ETDEWEB)
This paper studies the effects of axial heat conduction in boreholes used in geothermal heat pump systems. The axial effects are examined by comparing the results obtained using the finite and infinite line source methods. Using various practical design problems, it is shown that axial effects are relatively important. Unsurprisingly, short boreholes and unbalanced yearly ground loads lead to stronger axial effects. In one example considered, it is shown that the borehole length is 15% shorter when axial conduction effects are considered. In another example dealing with underground water freezing, the amount of energy that has to be removed to freeze the ground is three times higher when axial effects are considered. (author)
2010-04-15
Overview of Cooling Water System for the KSTAR 1st Plasma Experiment
International Nuclear Information System (INIS)
The KSTAR cooling water system (CWS) consists of a primary cooling water system (PCWS), a secondary cooling water system (SCWS), and a de-mineralizing and de-ionized water system (DIWS). The PCWS cooling loops have been made for the poloidal field (PF) and toroidal field (TF) magnet power supplies (MPS), vacuum vessel (VV), electron cyclotron heating (ECH), ion cyclotron heating (ICRH), vacuum pumps, diagnostics, helium facility, etc. The CWS had been done individual commissioning of each system to confirm the design specifications by the end of 2006 and had gradually begun operation for the KSTAR ancillary devices by March 2008
2009-05-01
Geothermal heat pump applications: Industrial/commercial
Energy Technology Data Exchange (ETDEWEB)
The fastest rate of growth in the space conditioning market has been attributed to the application of geothermal heat pumps to the industrial and commercial markets. The author reviews and provides examples of the three most popular components of a large geothermal heat pump system: geothermal earth coupling, heat pumps and heat exchangers, and building side terminals. These components are applied to three example geothermal installations: a library, an office building, and a school. Examples of energy use before and after the installation of a geothermal space conditioning system are summarized. General design and cost guidelines and comments on the use of geothermal heat pump in these and similar applications are discussed.
1999-07-01
Geothermal heat pumps - gaining ground in the UK and worldwide
Energy Technology Data Exchange (ETDEWEB)
This 2001 edition of the guide to UK renewable energy companies examines the geothermal heat pump sector, and discusses the technology involved, installations of geothermal heat pumps, the activity in the UK market with increased interest in UK geothermal heat pump products from abroad, and developments in the building sector. The UK government's increased support for the industry including its sponsorship of the Affordable Warmth programme, and the future potential of ground source systems are discussed.
2001-07-01
Geothermal heat pumps - gaining ground in the UK and worldwide
International Nuclear Information System (INIS)
This 2001 edition of the guide to UK renewable energy companies examines the geothermal heat pump sector, and discusses the technology involved, installations of geothermal heat pumps, the activity in the UK market with increased interest in UK geothermal heat pump products from abroad, and developments in the building sector. The UK government's increased support for the industry including its sponsorship of the Affordable Warmth programme, and the future potential of ground source systems are discussed.
Experimental evaluation of a non-azeotropic working fluid for geothermal heat pump system
Energy Technology Data Exchange (ETDEWEB)
Geothermal energy resources are found in many countries. A reasonable and efficient utilization of these resources has been a worldwide concern. The application of geothermal heat pump systems (GHPS) can help increase the efficiency of using geothermal energy and reduce the thermal pollution to the earth surface. However, this is only possible with a proper working fluid. In this paper, a non-azeotropic working fluid (R290/R600a/R123) is presented for a GHPS where geothermal water at 40-45{sup o}C and heating network water at 70-80{sup o}C serve as the low and high temperature heat sources. Experimental results show that the coefficient of performance (COP) of a GHPS using the working fluid is above 3.5 with the condensation temperature above 80{sup o}C and the condensation pressure below 18 bar, while the temperature of the geothermal water ...
2004-06-01
Experimental evaluation of a non-azeotropic working fluid for geothermal heat pump system
International Nuclear Information System (INIS)
Geothermal energy resources are found in many countries. A reasonable and efficient utilization of these resources has been a worldwide concern. The application of geothermal heat pump systems (GHPS) can help increase the efficiency of using geothermal energy and reduce the thermal pollution to the earth surface. However, this is only possible with a proper working fluid. In this paper, a non-azeotropic working fluid (R290/R600a/R123) is presented for a GHPS where geothermal water at 40-45 deg. C and heating network water at 70-80 deg. C serve as the low and high temperature heat sources. Experimental results show that the coefficient of performance (COP) of a GHPS using the working fluid is above 3.5 with the condensation temperature above 80 deg. C and the condensation pressure below 18 bar, while the temperature of the geothermal water is ...
2004-06-01
Geothermal heat-pump systems of heat supply
International Nuclear Information System (INIS)
The data on the multilayer operation of the objects, located in the climatic conditions of the central area of Russia and equipped with the geothermal heat-pumping systems of the heat supply are presented. The results of the analytical studies on evaluating the geothermal heat-pumping systems of the heat supply integration efficiency into the structure of the energy supply system, prevailing in the country, are presented
2004-06-01
Energy Technology Data Exchange (ETDEWEB)
Energy savings performance contracting (ESPC) is now receiving greater attention as a means of implementing large-scale energy conservation projects in housing. Opportunities for such projects exist for military housing, federally subsidized low-income housing, and planned communities (condominiums, townhomes, senior centers), to name a few. Accurate prior (to construction) estimates of the energy savings in these projects reduce risk, decrease financing costs, and help avoid post-construction disputes over performance contract baseline adjustments. This paper demonstrates an improved method of estimating energy savings before construction takes place. Using an engineering model calibrated to pre-construction energy-use data collected in the field, this method is able to predict actual energy savings to a high degree of accuracy. This is verified with post-construction energy-use data from a geothermal heat pump ESPC at Fort Polk, Louisiana. ...
1998-10-01
Energy Technology Data Exchange (ETDEWEB)
Energy savings performance contracting (ESPC) is now receiving greater attention as a means of implementing large-scale energy conservation projects in housing. Opportunities for such projects exist for military housing, federally subsidized low-income housing, and planned communities (condominiums, townhomes, senior centers), to name a few. Accurate prior (to construction) estimates of the energy savings in these projects reduce risk, decrease financing costs, and help avoid post-construction disputes over performance contract baseline adjustments. This paper demonstrates an improved method of estimating energy savings before construction takes place. Using an engineering model calibrated to pre-construction energy-use data collected in the field, this method is able to predict actual energy savings to a high degree of accuracy. This is verified with post-construction energy-use data from a geothermal heat pump ESPC at Fort Polk, Louisiana. ...
1998-01-01
Renewable energy technologies for federal facilities: Geothermal heat pump
Energy Technology Data Exchange (ETDEWEB)
This sheet summarizes information on geothermal heat pumps (GHPs), which extracts heat from the ground in the winter and transfers heat to the ground in the summer. More than 200,000 GHPs are operating in US; they can reduce energy consumption and related emissions by 23 to 44% compared to air-source heat pumps. Opportunities for use of GHPs, requirements, and cost are described. Important terms are defined.
1996-05-01
Diffusion absorption heat pump. Diffusion-Absorptions-Waermepumpe
Energy Technology Data Exchange (ETDEWEB)
The development of a gas-operated diffusion absorption heat pump for the heating of living spaces is described. By various improvement an energy efficiency of the prototypes of 1.5 was achieved. Structural alterations led to a lower overall height and lower production costs. The CFCs used in electric heat pumps were replaced by environmentally neutral ammonia. Compared with conventional gas heating systems, the CO2 output could be reduced by more than 30%. figs., tabs.
1992-02-01
Program listing for heat-pump seasonal-performance model (SPM). [CNHSPM
The computer program CNHSPM is listed which predicts heat pump seasonal energy consumption (including defrost, cyclic degradation, and supplementary heat) using steady state rating point performance and binned weather data. (LEW)
1982-06-30
Thermodynamic analysis of a hybrid geothermal heat pump system
British Library Electronic Table of Contents (United Kingdom)
A thermodynamic analysis of a hybrid geothermal heat pump system is carried out. Mass, energy, and exergy balances are applied to the system, which has a cooling tower as a heat rejection unit, and system performance is evaluated in terms of coefficient of performance and exergy efficiency. The heating coefficient of performance for the overall system is found to be 5.34, while the corresponding exergy efficiency is 63.4%. The effect of ambient temperature on the exergy destruction and exergy efficiency is investigated for the system components. The results indicate that the performance of hybrid geothermal heat pump systems is superior to air-source heat pumps.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Using the past diffusion trends of four renewable energy technologies for irrigation water pumping in India (SPV pumps, windmill pumps and biogas/producer gas driven dual fuel engine pumps), results of an attempt to project their future dissemination levels, have been presented in this study. The likely contribution of the renewable energy options considered in the study to the projected energy demand for irrigation water pumping in India has been estimated. Estimates of the associated investment requirements taking into account the learning effect have also been presented. (author)
2005-12-01
Energy Technology Data Exchange (ETDEWEB)
An approximate solution was proposed in which a sensitivity analysis by the storage and release of heat was performed for the subject issues and in which an operating method was thereby determined for the equipment constituting the system by means of a linear programming. Accordingly, a heat storage type energy supply system for a district cooling and heating was taken up as a concrete object to be examined. This system consisted of a gas turbine generator, initial power receiving equipment, gas boiler, electric heat pump for ice heat storage, cooling tower, heat exchanger, steam absorbing refrigerating machine, ice heat storage tank, cold and warm water heat storage tank, etc. As a result of comparison between the proposed method and the resolving method, the former showed -0.92 ...
1996-02-01
Energy Technology Data Exchange (ETDEWEB)
Visits were made to selected manufacturing units with 25 or more employees. Information was gathered on energy consumption and advice was given on the opportunities available for improving the efficiency of energy use. Potential energy savings are estimated and recommendations are made on the action that should be taken to improve the efficiency of energy use. In the footwear industry space heating controls, improvements in boiler plant and steam services along with building insulation provide most of the savings potential. In the leather industries major energy saving opportunities can be found in low-temperature drying, and heat recovery, where the use of heat pumps could contribute substantial savings in drying and process water heating. Boiler controls and good housekeeping are areas where firms can make worthwhile savings at very little capital cost. (MCW)
1980-11-01
Energy Technology Data Exchange (ETDEWEB)
The Lincoln Public School District, in Lincoln, Nebraska, recently installed vertical-bore geothermal heat pump systems in four, new, elementary schools. Because the district has consistent maintenance records and procedures, it was possible to study repair, service and corrective maintenance requests for 20 schools in the district. Each school studied provides cooling to over 70% of its total floor area and uses one of the following heating and cooling systems: vertical-bore geothermal heat pumps (GHPs), air-cooled chiller with gas-fired hot water boiler (ACUGHWB), water-cooled chiller with gas-fired hot water boiler (WCCYGHWB), or water-cooled chiller with gas-fired steam boiler (WCUGSB). Preventative maintenance and capital renewal activities were not included in the available database. GHP ...
1999-06-19
Energy Technology Data Exchange (ETDEWEB)
Simple frameworks have been developed for estimating the utilization potential of: (a) solar photovoltaic (SPV) pumps; (b) windmill pumps; (c) producer gas based dual fuel engine pumps; and (d) biogas based dual fuel engine pumps for irrigation water pumping in India. The approach takes into account factors such as: solar radiation intensity, wind speed, availability of bovine dung and agri-residues, and their alternative uses, ground water requirements for irrigation and its availability, affordability, and propensity of the users to invest in renewable energy devices, etc. SPV pumps are estimated to have the maximum utilization potential in India, followed by windmill pumps. (author)
2007-05-15
Flow Vaporization of CO{sub 2} in Microchannel Tubes
Energy Technology Data Exchange (ETDEWEB)
Carbon dioxide is receiving renewed interest as an efficient and environmentally safe refrigerant in a number of applications, including mobile air conditioning and heat pump systems, and hot water heat pumps. Compact heat exchangers for CO{sub 2} systems are designed with small-diameter tubing. The purpose of this study is therefore to provide a better basis for understanding and predicting heat transfer and pressure drop during flow vaporization of CO{sub 2} in microchannels. The ''unusual'' properties of carbon dioxide give heat transfer and two-phase flow characteristics that are very different from those of conventional refrigerants. Examples of these differences are the much higher pressure, the resulting high vapour density, a very low surface tension, and a low liquid ...
2002-07-01
Finalisation of design provision for active process water system shut down at TAPP-3 and 4
International Nuclear Information System (INIS)
Active Process Water (APW) system is provided as a unitized system in TAPP-3 and 4. Maintenance on APW system requires shutdown of this system. As shut down heat exchangers are fed by APW system; during APW system shutdown cold shutdown state cannot be maintained. Therefore safety analysis is done to optimize the duration of reactor shutdown (which means low decay heat) after which APW shutdown can be taken with minimum water supply to the shutdown heat exchangers. Based on this analysis, it is proposed in technical specification that APW system shutdown can be taken after 7 days of reactor shutdown with shutdown heat exchangers supplied with about 20 % of normal APW flow. With this configuration, PHTS, moderator, end shield, calandria vault water temperature can be maintained within limits. A design provision is made at TAPP-3 and 4 to ...
2006-11-13
Geothermal heat-pump systems are competing today against conventional fuels
Energy Technology Data Exchange (ETDEWEB)
The alternative to the use of deeper wells through temperature amplification of the geothermal resource by electric heat pumps is explored. Systems in Ephrata, Washington and Chamberlain, South Dakota are explored. (MHR)
1982-12-01
Energy Technology Data Exchange (ETDEWEB)
This final report for the Swiss Federal Office of Energy (SFOE) examines a project that aimed to define standard solutions for use in buildings built to meet Minergie low energy consumption standards. These standard solutions are to provide a way of meeting Minergie standards in an easy way and thus further the use of the standard and also assure quality at the same time. The report describes how the solutions were developed on the basis of a selection of existing Minergie buildings. For various combinations of heating systems - wood, wood/solar, heat pumps (brine-water and air-water), gas/solar and oil/solar - the appropriate U-values for various building elements are listed. The resulting Minergie forms and guides are listed.
2003-07-01
LOBI/B-R1M, Loop for Blowdown Investigation, PWR Single-Ended Cold-Leg Break Experiment B EXP.B
International Nuclear Information System (INIS)
1 - Description of test facility: The LOBI facility is a 1/700 scale model of a four loop PWR and has two primary loops, the intact loop representing three loops and the broken loop representing one loop of a four-loop PWR. The reactor pressure vessel model contains an electrically heated rod-bundle with 64 rods and a heated length of 3.9 m. The nominal heating power is 5.3 MW. The downcomer is of annular shape. An upper head simulator is connected to the vessel. Each of the two primary loops contains a pump and a steam generator. The different mass flows in the loops are established by the pump speeds, since the two pumps are identical. Heat is removed from the steam generators by a secondary system. ECC water can be supplied from two accumulators, one for each loop. Cold or hot leg as well as combined injection can be ...
Residential vertical geothermal heat pump system models: Calibration to data
Energy Technology Data Exchange (ETDEWEB)
A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was tuned to better match the measured data from the site. These tuned models were then interconnected to form the system model. The system model was then exercised in order to demonstrate its capabilities.
1997-12-31
Residential Vertical Geothermal Heat Pump System Models: Calibration to Data:
Energy Technology Data Exchange (ETDEWEB)
A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was 'tuned' to better match the measured data from the site. These tuned models were then interconnect to form the system model. The system model was then exercised in order to demonatrate its capabilities.
1997-06-01
New crafts of a master builder
Energy Technology Data Exchange (ETDEWEB)
Innovative new ideas for the construction of homes are described. A thermal energy storage system fireplace and a geothermal heat pump for homes are described.
1983-11-01
Energy Technology Data Exchange (ETDEWEB)
Late 1994, the Geothermal Heat Pump Consortium (GHPC) was launched as a non-profit collaborative effort between the United States Department of Energy, US electric utilities and the GeoExchange (geothermal heat pump) industry to make ''geothermal heat pumps'' a significant component of the HVAC industry and avoid 1.5 million metric tons of carbon equivalent per year. The goal was to create a self-sustainable GeoExchange market. This report offers a summary of some of the lessons learned and an overview of some of the programs major accomplishments.
2001-04-30
Ground source heat for heat pumps; Erdgekoppelte Waermequellen fuer Waermepumpen
Energy Technology Data Exchange (ETDEWEB)
Under the new name of ``geothermal heat pump``, ground-source heat pumps are currently high in demand in Northern America. In sectors characterized by heating and cold air demand, their advantages can be exploited to the full. For Germany, the end-use-energy substitution potential of geothermal heat pumps has been estimated at 1310-1470 PJ annually. Whether this potential can actually be exploited depends essentially on the development of energy prices, but also on the resourcefulness of plant and heat pump manufacturers in upgrading and cheapening geothermal heat pumps. (orig./RHM) [Deutsch] Unter der neuen Bezeichnung `Geothermal Heat Pump` erlebt die erdgekoppelte Waermepumpe z.Zt. in Nordamerika einen ...
1996-12-31
Potential for hot-dry-rock geothermal resources: experimental results
Hot dry rock (HDR) contains insufficient permeability and fluid for natural hydrothermal development, but water pumped in a circulation loop through a HDR reservoir (hydraulically fractured between two drill holes) is being tested and evaluated. The formation of such in situ heat transfer systems, and subsequent testing of the man-made geothermal reservoirs in the Jemez volcanic field, New Mexico have already indicated the technical feasibility of the hot dry rock (HDR) geothermal concept. Documented production history and heat-extraction data obtained during the period from 1978 to 1980 have confirmed heat transfer, low water loss, and predictable thermal drawdown models for the HDR systems. During a nine month test of closed-loop heat extraction operations, 15 x 10/sup 6/ kWh of thermal energy were produced. The effective ...
1982-01-01
Thermally conductive cementitious grouts for geothermal heat pumps. Progress report FY 1998
Energy Technology Data Exchange (ETDEWEB)
Research commenced in FY 97 to determine the suitability of superplasticized cement-sand grouts for backfilling vertical boreholes used with geothermal heat pump (GHP) systems. The overall objectives were to develop, evaluate and demonstrate cementitious grouts that could reduce the required bore length and improve the performance of GHPs. This report summarizes the accomplishments in FY 98. The developed thermally conductive grout consists of cement, water, a particular grade of silica sand, superplasticizer and a small amount of bentonite. While the primary function of the grout is to facilitate heat transfer between the U-loop and surrounding formation, it is also essential that the grout act as an effective borehole sealant. Two types of permeability (hydraulic conductivity) tests was conducted to evaluate the sealing performance of the cement-sand grout. Additional properties of the proposed grout ...
1998-11-01
Energy nomographs as a design tool for daylighting
Energy Technology Data Exchange (ETDEWEB)
The purpose of this paper is to inform commercial building designers about an energy analysis tool which can aid them in making appropriate decisions about daylighting. The energy nomographs are an energy design tool which calculate the annual energy consumption of commercial buildings, including lighting, heating, cooling, domestic hot water, fans, pumps, and miscellaneous items. This paper specifically discusses the daylighting aspects of the tool. The calculation procedure is presented with an example to explain how this design tool can be used to make good energy decisions early in the design process.
1984-01-01
Restoration of a forested wetland ecosystem in a thermally impacted stream corridor
Energy Technology Data Exchange (ETDEWEB)
The Savannah River Swamp is a 3,020 Ha forested wetland on the floodplain of the Savannah River and is located on the Department of Energy`s Savannah River Site (SRS). Major impacts to the swamp hydrology occurred with the completion of the production reactors and one coal-fired powerhouse at the SRS in the early 1950`s. Water was pumped from the Savannah River, through secondary heat exchangers of the reactors, and discharged into three of the tributary streams that flow into the swamp. This continued from 1954 to 1988 at various levels. The sustained increases in water volume resulted in overflow of the original stream banks and the creation of additional floodplains. Accompanying this was considerable erosion of the original stream corridor and deposition of a deep silt layer on the newly formed delta. Heated water was discharged directly into Pen Branch and ...
1995-09-01
Energy Technology Data Exchange (ETDEWEB)
An exergoeconomic model of a vertical ground-source heat pump residential heating system presented in this study uses exergy and cost energy mass (EXCEM) methods. The data obtained from a ground-source heat pump (GSHP) residential heating system installed at the Solar Energy Institute, Ege University, Turkey, are utilized for calculations at different reference temperature values in the range 0-25{sup o}C. The performance of the geothermal heat pump residential heating system is evaluated to indicate how exergoeconomic parameter values change with system. We also undertake a parametric study to investigate how varying reference temperatures will affect the exergoeconomic analysis of the GSHP system. A correlation between the ratio of thermodynamic loss rate to capital cost and reference state ...
2007-03-15
Physical modeling of flow control device test in intake structure
International Nuclear Information System (INIS)
The seawater in the intake structure flows into the large pump to with draw excess heat from the turbine steam condenser. In the intake structure of a nuclear power plant, undesirable pump operating characteristics such as vortices, impeller damages and non-uniform pump-approach flow around the pump bells take place frequently due to poorly-arranged intake geometry. In this study, physical modeling test was performed to predict the hydraulic phenomenon, and proposed flow control devices.
2000-05-01
Energy Technology Data Exchange (ETDEWEB)
Versatility of the TRNSYS software program, the ease with which new components can be incorporated into the software, and its application to simulate heat pump systems was discussed. A case history was described in which the package, augmented by the addition of several recent large-scale heat pump projects, was used in calibrating a residential geothermal heat pump system at a military housing project in Fort Polk, LA. The project involved retrofitting over 4000 air source heat pumps with geothermal heat pumps in an energy savings performance contract. The calibration of the component models led to a system model which accurately predicts the performance of the geothermal heat pump. The lessons learned from the calibration exercise were ...
1997-11-01
Potential for geothermal development in Southern Poland
Energy Technology Data Exchange (ETDEWEB)
This paper discusses the potential for geothermal energy use in the central part of Southern Poland, such as the availability of thermal aquifers and the techniques for putting the latter to practical use. The geological and geothermal features of the region are presented within the context of the existence of aquifers containing geothermal resources that could be used in space heating. Also discussed are the three main geological units where thermal waters are known to exist: the Carpathians, the Miechow Trough, and the Silesian-Cracow Monocline. Particularly favourable hydrogeological conditions exist in the Inner Carpathians, in the Podhale Trough, where there is already one geothermal company using geothermal energy, Geotermia Podhalanska S.A. Equally interesting from the geothermal point of view are the areas north of the Cracow-Tarnow line, where, in Mesozoic aquifers, water temperatures range from 20 to 60 {sup o}C. ...
2004-06-01
Model tests on a semi-axial pump turbine
Energy Technology Data Exchange (ETDEWEB)
Due to their good hydraulic characteristic semi-axial pump turbines are used in the medium head range of pumped storage plants. This paper describes model tests performed on a semiaxial pump turbine model and shows the results of these tests. The aim of the model tests was the optimization of the hydraulic water passage, the measurement of the hydraulic characteristics over the whole operating range, the investigation of the cavitation behaviour, the investigation of the hydraulic forces and torques as well as the proof of the values guaranteed to the customer.
1984-03-01
International Nuclear Information System (INIS)
Ground-source heat pump systems (GSHPSs), also referred to as geothermal heat pump systems (GHPSs), have been widely used in residential and commercial buildings for years due to their outstanding energy utilization efficiencies. In this study, an energy and exergy modeling of solar assisted ground-source heat pump systems for residential applications is presented for system analysis and performance evaluation. In this regard, the performance of a solar assisted ground-source heat pump heating system, installed in Solar Energy Institute of Ege University, Izmir, Turkey, is evaluated based on the actual operational data to show how energy and exergy efficiencies values change with the system. The average heating coefficient of performances (as energy efficiencies) of the solar ...
2005-06-12
New technology for purging the steam generators of nuclear power plants
British Library Electronic Table of Contents (United Kingdom)
A technology for removal of undissolved impurities from a horizontal steam generator using purge water is developed on the basis of a theoretical analysis. A purge with a maximal flow rate is drawn off from the zone with the highest accumulation of sludge in the lower part of the steam generator after the main circulation pump of the corresponding loop is shut off and the temperatures of the heat transfer medium at the inlet and outlet of the steam generator have equilibrated. An improved purge configuration is used for this technology; it employs shutoff and regulator valves, periodic purge lines separated by a cutoff fixture, and a D y 100 drain union as a connector for the periodic purge. Field tests show that the efficiency of this technology for sludge removal by purge water is severa...
2011-01-01
Device for energy-saving heating of fuel in the fuel supply for an internal combustion engine
Energy Technology Data Exchange (ETDEWEB)
The invention concerns a device for the energy-saving heating of fuel in the supply pipe to an internal combustion engine to regain energy from the fuel itself, particularly but not exclusively for a Diesel engine. A part of the quantity of heat added to the fuel between the tank and the injection nozzles is given up by excess fuel not to the tank, but to the fuel lifted upstream of the injection pump. The device is characterised by the fact that it has a heat exchanger, which absorbs heat from the fuel at the level of the injection pump or upstream of it, and takes this to the fuel above the injection pump. The heat exchanger is preferably mounted upstream of a filter and close to it. A bridging pipe, which may be integrated in the heat exchanger, permits the heat exchanger to ...
1981-02-10
A comparison of convenience features for Japanese and American residential heat pumps
Energy Technology Data Exchange (ETDEWEB)
The fundamental differences in the type of products sold in both Japan and the US, and some of the reasons for these differences, are outlined. Japan is the largest single country market for residential heat pumps, while the US represents the largest single country market for residential heating equipment. Quite different types and associated features of heat pumps are demanded in the USA and Japan. The term `convenience features`, used to describe the physical characteristics of the user interface device, is explained, as well as the fundamental reasons leading to the particular styles of product sold in each country: (1) product strategy and sales channels, (2) design of housing, (3) climatic factors, and (4) energy costs and distribution. It is stressed that there is no big cooling load in Japan. It is rather the comfort issue that drives the market for heat ...
1996-07-01
Pumped storage plants 20 are a relatively common type.They use a dam to create an upper reservoir ...Some pumped storage plants use the same water turbine and electric generator for both operating periods.That is,
Pumped storage plants are a relatively common type.They use a dam to create an upper reservoir ...Some pumped storage plants use the same water turbine and electric generator for both operating periods.
Large temperature differential thermal storage system. Its design and evaluation
Energy Technology Data Exchange (ETDEWEB)
A large temperature differential (10K) thermal storage system in a small (4400 m{sup 2}) 8-storey office building is discussed and the monitoring results are analyzed in comparison with computer simulations. Requirements were a comfortable indoor environment and system cost effectiveness. Out of four potential system concepts, the Large Temperature Differential System was chosen. It comprises a flat-type thermal stratification heat storage tank in the under floor pit of the building as the heat source for a variable flow heat pump chiller. The heat sink is a set of serially connected air handling and fan coil units. The tank`s capacity is sized for one day operation and is made as large as possible to shift the electricity demand to night time. To avoid a large size and high cost, the water temperature differential was enlarged. The role of Tokyo Electric Power ...
1996-07-01
CATHENA simulation of the WOLSUNG D_20 spill incident of 1984 November 25
International Nuclear Information System (INIS)
The CATHENA (formerly ATHENA) has been used to simulate the thermalhydraulic behaviour of the WOLSUNG-1 CANDU-600 reactor during the D_20 spill incident of 1984 November 25. A 4-inch (nominal) Liquid Relief Valve inadvertently opened in the reactor auxiliary system during normal reactor operation, resulting in a discharge of heavy water from the primary heat transport system. The valve remained open for approximately 29 minutes. CATHENA is an advanced thermalhydraulic computer code for analysis of postulated loss-of-coolant accidents (LOCA) and transient faults in CANDU nuclear reactors. A full two-fluid (six-equation) representation of the two-phase flow is used. Component models are used to represent pumps, valves, critical discharge, etc., which are necessary to describe the behaviour of the CANDU system under upset conditions. Heat transfer between the fluid and piping walls (or fuel) is modelled ...
1986-06-09
The trick with the heat pump; Der Trick mit der Waermepumpe
Energy Technology Data Exchange (ETDEWEB)
The brochure reports on the construction and method of operation of heat pumps: - Efficiency and temperature difference - output figure - circuit processes - saving of primary energy - monovalent and bivalent plants - absorber, earth collectors - heat recovery. (HW) [Deutsch] Die Broschuere berichtet ueber den Aufbau und die Wirkungsweise von Waermepumpen: - Wirkungsgrad und Temperaturdifferenz - Leistungszahl - Kreisprozesse - Einsparung von Primaerenergie - monovalente und bivalente Anlagen - Absorber, Erdkollektoren - Waermerueckgewinnung. (HW)
1997-12-31
Energy Technology Data Exchange (ETDEWEB)
Heat pumps can be installed indoors or outdoors. H. Klein investigates which site would be preferable for a one-family house. Advantages and disadvantages with regard to necessary space, noise, maintenance and repair are discussed; heat losses in both cases of installations are dealt with. Mathematic calculation shows that indoor installation is safer and more adequate in terms of energy savings.
1982-06-01
Energy Technology Data Exchange (ETDEWEB)
This workshop on heat pipes and two-phase capillary pumping loops was organized by the French society of thermal engineers. The 11 papers presented during this workshop deal with the study of thermal performances of heat pipes and on their applications in power electronics (cooling of components), and their use in satellites, aircrafts and trains. (J.S.)
1996-12-31
Geothermal heat pump performance and utility programs in the United States
Energy Technology Data Exchange (ETDEWEB)
Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past 10 years in the United States. These systems offer substantial benefits to consumers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data were available mainly from electric utilities on heat pump performance, energy savings, and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market entry, incentive programs, and benefits.
1997-01-01
Geothermal heat pump performance
Energy Technology Data Exchange (ETDEWEB)
Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to customers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market penetration, incentive programs, and benefits.
1995-12-31
Financial evaluation of renewable energy technologies for irrigation water pumping in India
International Nuclear Information System (INIS)
An attempt to develop a simple framework for financial evaluation of renewable energy technologies (RETs) such as photovoltaic (PV) pump, windmill pump, biogas and producer gas-driven dual fuel engine pumps for irrigation water pumping has been made. The unit cost of water and unit cost of useful energy delivered by the RETs have been estimated. The monetary benefits that accrued to the end-user have been quantified in terms of the amount of diesel or electricity saved. Financial figures of merit for the investments made in the RETs have been estimated. The effect of fuel price escalation on these measures of financial performance has also been evaluated along with the estimation of the break-even prices of fuels likely to be substituted by RETs. Results of some exemplifying calculations are presented and briefly discussed.
2007-06-01
Energy Technology Data Exchange (ETDEWEB)
This comprehensive final report for the Swiss Federal Office of Energy (SFOE) presents the results of research done in the third phase of a research project that investigated components for small heat pump systems that use ammonia as a working fluid. The report includes a summary of the findings of the first two phases of the project and goes on to describe tests done with rotary vane and scroll compressors. The aims of the project are discussed and the work done is listed chronologically. The construction and the components of the test installation are described in detail. Also, the heat pump testing facilities at the University of Applied Science in Rapperswil, Switzerland, are described. The results of the measurements made for various temperature gradients are presented in detail and commented on; also, the various types of compressor tested and other heat ...
2003-07-01
Ultra-high pressure water jet: Baseline report
International Nuclear Information System (INIS)
The ultra-high pressure waterjet technology was being evaluated at Florida International University (FIU) as a baseline technology. In conjunction with FIU's evaluation of efficiency and cost, this report covers the evaluation conducted for safety and health issues. It is a commercially available technology and has been used for various projects at locations throughout the country. The ultra-high pressure waterjet technology acts as a cutting tool for the removal of surface substrates. The Husky trademark pump feeds water to a lance that directs the high pressure water at the surface to be removed. The safety and health evaluation during the testing demonstration focused on two main areas of exposure. These were dust and noise. The dust exposure was found to be minimal, which would be expected due to the wet environment inherent in the technology, but noise exposure was at a significant level. Further testing for noise is ...
1997-07-01
Energy Technology Data Exchange (ETDEWEB)
This book includes the latest developments and covers pump performance, selection and operations, materials, seals and packings, effective fluid characteristics, filtration, piping systems, economics, valves, instrumentation, automatic controls, power transmission equipment, pump and pipeline heating, and more. An extensive data section contains formulas, charts, symbols, nomographs, and standard specification documents.
1984-01-01
Device for controlling water supply to nuclear reactor
International Nuclear Information System (INIS)
Object: To smoothly control automatic water supply for realizing stable operation of a nuclear reactor by providing a flow rate limiting signal selection circuit and a preferential circuit in a water supply control device for a nuclear reactor wherein the speed of a recirculation pump may be changed in two-steps. Structure: Opening angle signals for a water supply regulating valve are controlled by a nuclear reactor water level signal, a vapor flow rate signal and a supplied water flow rate signal through an adder and an adjuster in response to a predetermined water level setting signal. When the water in the reactor is maintained at a predetermined level, a selection circuit receives a water pump condition signal for selecting one of the signals from a supplied ...
Emergency core cooling device for a reactor
International Nuclear Information System (INIS)
Purpose : To obtain an emergency core cooling device in a FBR type reactor by utilizing heat pipes which are not actuated at usual operation condition but actuated reliably upon emergency. Constitution : A system for injecting heat medium into heat pipes is provided. By injecting the heat medium into the heat pipes upon emergency to actuate the heat pipes, the reactor core is cooled. During normal reactor operation, the inside of the heat pipes is evacuated from a vacuum pump and no heat medium is filled therein, whereby unnecessary heat loss during the normal operation can be prevented. (Ikeda, J.).
1982-01-24
Development of sealing insulator for electric penetration assemblies
International Nuclear Information System (INIS)
Electrical penetration assemblies mounted on the containment wall are used to carry electrical power and signals from the equipment inside this containment (e.g. recirculation pumps, control rod position indications etc.) Todays BWR nuclear power plants apply epoxy resin sealed electric penetration. Contrariwise, the epoxy resin (organic sealant) was replaced with sodium barium glass (inorganic) by way of trial in search for a quality sealant. The glass sealant has been proved to have high temperature airtightness at 300 degC above from an evaluation test involving full-scale model parts. Environmental tests were conducted continuously as to heat cycle, vibration and LOCA etc. the specimens (module) of five types. They were made certain of conformity to the design requirements for boiling water operation. (author).
Energy Technology Data Exchange (ETDEWEB)
Recent developments in heat pump technology have made geothermal-based heat exchange systems particularly well-suited for the heating and cooling needs of buildings even in cold climates. The principles of geothermally-coupled heat pump heating and cooling systems were presented. Results of an in-situ study conducted by Hydro-Quebec on the efficiency of the geothermal heat pump system installed at the Saint-Hyacinthe professional school were summarized. This investigation was meant to be a case study of the applicability of these new technologies to the needs of the Quebec market. After the first year of service, the Saint-Hyacinthe system clearly demonstrated its cost effectiveness over conventional systems. It was predicted that geothermal heat pump systems ...
1996-03-01
Feedwater control device for a reactor
International Nuclear Information System (INIS)
Purpose: To stably control the reactor water level so as not to cause excess water feeding in a BWR type reactor. Constitution: A flow control valve is disposed to the exit of a feedwater pump for a nuclear reactor and the valve is controlled by a flow regulator to maintain the water level constant in the reactor. A signal from a water level controller is inputted to the flow regulator to thereby control the flow rate control valve. In this case, the flow regulator remains in a saturated state just after the starting of the feedwater pump, in which the pump flowrate is at 100% to result in an excess water feeding condition. In view of the above, a feedback circuit is provided to the flow regulator so that the saturated state is eliminated and the water feeding can be controlled directly from the ...
1981-11-12
Leak-before-break strategy for CANDU primary piping systems
Energy Technology Data Exchange (ETDEWEB)
Recent advances in elastic-plastic fracture mechanics have made it possible to assess the stability of cracks in ductile piping systems. These technological developments have been used by Ontario Hydro as the nucleus of an approach for demonstrating that CANDU primary heat transport piping systems will not break catastrophically; at worst they would leak at a detectable rate. This leak-before-break approach has been taken on the Darlington nuclear generating station as a design stage alternative to the provision of pipe whip restraints on large diameter, primary heat transport system piping. Positive conclusions reached via this approach are considered sufficient to exclude the requirement to provide protective devices, such as pipe whip restraints. In arriving at the proposed leak-before-break approach a review of current and proposed leak-before-break licensing positions of other jurisdictions (particularly those in the United States and the ...
1986-01-01
International Nuclear Information System (INIS)
In summary, a scaling analysis of a water-cooled Reactor Cavity Cooling System (RCCS) system was performed based on generic information on the RCCS design of PBMR. The analysis demonstrates that the water-cooled RCCS can be simulated at the ANL NSTF facility at a prototypic scale in the lateral direction and about half scale in the vertical direction. Because, by necessity, the scaling is based on a number of approximations, and because no analytical information is available on the performance of a reference water-cooled RCCS, the scaling analysis presented here needs to be 'validated' by analysis of the steady state and transient performance of a reference water-cooled RCCS design. The analysis of the RCCS performance by CFD and system codes presents a number of challenges including: strong 3-D effects in the cavity and the RCCS tubes; simulation of turbulence in flows characterized by natural ...
Program plan for development of underground hydroelectric pumped storage technology
The Underground Hydroelectric Pumped Storage (UHPS) Program Plan describes in detail the planned activities and expected accomplishments in the conduct of UHPS technology development and validation envisioned in the 1976 to 1990 time frame. This document describes the program objectives, implementation strategy, and management methodology. The concept of underground hydroelectric pumped storage is fully directed to application in the electric utility industry. This technology involves using electrical energy generated by base-load plants during off-peak load periods to drive a high-head pump/turbine which pumps water from a lower reservoir to a substantially elevated (upper) reservoir corresponding to a head of 1000 m or so. The upper reservoir is at ground level and the lower reservoir is below ground. Then, during peak-load periods, water in the upper ...
1976-03-01
International Nuclear Information System (INIS)
Tata Electric Companies (TEC) are engaged in the generation of hydro and thermal energy. TEC, to minimise backing down of its thermal units in off peak hours and also to at least partially meet the growing deficit in the supply during peak hours is moving to install pumped storage plants (PSPs) utilising off-peak surplus energy for pumping the water from lower pond to the upper pond for subsequent utilisation for power generation during peak hours. In view of some of the infra structural facilities such as storage ponds, water conductor system, transmission lines, etc. being already available, at the existing hydro power stations owned by TEC, the pumped storage units are being proposed within the environs of existing hydro stations, i.e. a 150 MW pumped storage unit at Bhira and a 90 MW pumped storage unit at Bhivpuri. The projects are ...
1992-01-01
Economic analysis for utilization of geothermal energy by North Dakota Concrete Products Co.
Energy Technology Data Exchange (ETDEWEB)
North Dakota Concrete Products Company uses a steam curing process that accelerates the concrete curing so that 28-day strength is obtained within 24 hours. The cost of energy required to accomplish this is significant, amounting to approximately $80,000 in 1980. The present boilers are oil fired. Recently, fuel oil prices have increased substantially. Further, supply shortages in the past have threatened plant production. The purpose of this study was to evaluate the economic feasibility of using deep formation warm water as an alternative energy source. A water-to-water heat pump system to replace the existing boiler system was investigated. TPI, Inc. economic and engineering findings for this particular potential geothermal application are disclosed. The operating cost savings of the geothermal system over the operating costs of the existing oilfired system would be insufficient to provide an ...
1982-02-01
Replacement of bearing journals on heat transport pumps at the Wolsung nuclear generating station
International Nuclear Information System (INIS)
The major details of the inspection and replacement of the bearing journals on each of the four heat transport pumps (HTPs) at Wolsung nuclear generating station in Korea are presented in this paper. Investigation following fracture of one of the journals in 1985 revealed that it was excessively hard. The journal material (ASTM A296 CA 40) is considered to be prone to stress corrosion fatigue if the hardness exceeds Rc 40. In 1986 May, during a planned outage, the HTPs were disassembled, the journals were inspected, found to be excessively hard, and all were replaced. At the same time, the pump to motor couplings were all refurbished to ensure proper alignment.
1987-11-22
Hydroelectric and pumped storage plants
Energy Technology Data Exchange (ETDEWEB)
All power plant engineers face the problem of peak power demands. Pumped storage plants are used to generate peak load power by pumping up water utilizing off-peak energy of hydrothermal and thermonuclear plants. This is the first accessible text/reference to cover hydroelectric power generation with emphasis on engineering to meet peak power demands by means of pumped storge plants, tidal power plants, and low head power generation. Text covers hydrology, mechanical and electrical equipment, accessories such as penstocks and valves, and civil engineering considerations. Contains descriptions of several existing plants. Includes 200 diagrams and 50 photographs.
1989-01-01
Hydroelectric and pumped storage plants
Energy Technology Data Exchange (ETDEWEB)
All power plant engineers face the problem of peak power demands. Pumped storage plants are used to generate peak load power by pumping up water utilizing off-peak energy of hydrothermal and thermonuclear plants. This is a reference to cover hydroelectric power generation with emphasis on engineering to meet peak power demands by means of pumped storage plants, tidal power plants, and low head power generation. Text covers hydrology, mechanical and electrical equipment, accessories such as penstocks and valves, and civil engineering considerations. Contains descriptions of several existing plants. Includes 200 diagrams and 50 photographs.
1988-01-01
Back-up for high voltage cable pressurizing system
Energy Technology Data Exchange (ETDEWEB)
A back-up system is provided for a pumping plant or a pressure reservoir system used to maintain insulating oil under pressure in high voltage submarine power cables which includes a gas driven membrane pump to insure a small outflow of oil at a rupture point in the power cable to prevent water from penetrating the cable. The proper operation of the membrane pump is insured by introducing degasified oil at the drive side of the pump during the stand-by and test modes of operation of the back-up system. 11 drawings.
1982-07-19
Heat pumps in urban space heating systems: Energy and environmental aspects
International Nuclear Information System (INIS)
A statistical survey is conducted of air pollution in the city of Rome (Italy) due to conventional building space heating systems burning fossil fuels. The survey identifies the annual consumption of the different fuels and the relative amounts of the various pollutants released into the atmosphere by the heating plants, e.g., sulfur and nitrogen oxides, carbon monoxide, etc. Comparisons are then made between the ratios of urban heating plant air pollutants produced per tonne of fuel employed and those for ENEL (Italian National Electricity Board) coal, oil and natural gas fired power plants, in order to demonstrate the better environmental performances of the utility operated energy plants. The building space heating system energy consumption and pollution data are then used in a cost benefit analysis favouring the retrofitting of conventional heating systems with ...
1991-01-01
THERMALLY CONDUCTIVE CEMENTITIOUS GROUTS FOR GEOTHERMAL HEAT PUMPS. PROGRESS REPORT BY 1998
Energy Technology Data Exchange (ETDEWEB)
Research commenced in FY 97 to determine the suitability of superplasticized cement-sand grouts for backfilling vertical boreholes used with geothermal heat pump (GHP) systems. The overall objectives were to develop, evaluate and demonstrate cementitious grouts that could reduce the required bore length and improve the performance of GHPs. This report summarizes the accomplishments in FY 98.
1998-11-01
Simulation of a geothermal heat pump with non-azeotropic mixture
Energy Technology Data Exchange (ETDEWEB)
The paper sets up a simulation of a geothermal heat pump with a non-azeotropic mixture. The model is modified and verified with experimental data. The results of the simulation show that the systematic model can predict the performance within {+-}12% of the experimental data. As a result, some improvements can be provided on the basis of the simulation platform. (Author)
2003-08-01
Developing geothermal heat pump demonstration projects
Energy Technology Data Exchange (ETDEWEB)
The Sacramento Municipal Utility District is developing a number of demonstration projects using geothermal heat pumps. This paper discusses some of the barriers and issues that have emerged over the past two years. The most important barriers are: regulatory impediments; high first cost; and a lack of local design and installation infrastructure.
1995-12-31
Energy Technology Data Exchange (ETDEWEB)
Why pay for energy when there`s a free stockpile of it right under your feet? With the help of a geothermal heat pump system, one can extract that energy from the ground and put it to good use, lowering heating and cooling costs. From private homes to public schools and fast-food restaurants, an increasing number of establishments are turning to geothermal heat pump systems for space conditioning. Experts say 1998 is already proving to be the best year yet for the technology, and they foresee an even more promising future. Some examples of geothermal energy use are given.
1998-05-01
Preliminary study of the effect of pumped-storage plant operation on zooplankton
Energy Technology Data Exchange (ETDEWEB)
The hydromechanical effect of hydroelectric stations on zooplankton is customarily regarded as a constantly acting and comparatively harmless factor, since its destruction is inevitable when water masses are passed through hydroelectric stations, but its capacity for restoration is high (i.e., destruction of the zooplankton of the forebay is compensated by its production in the after bay). It is not known how correct such an opinion is, or what is the true balance of losses and reproduction of zooplankton in the forebays and after bays of hydroelectric stations. However, hydroelectric plants of a new type, pumped-storage plants, have been constructed in recent years and others are planned for the Dnieper reservoirs. The operational principle and purpose of these plants is that they employ special vertical turbine-electric pumps that pump water at night from the reservoirs into ...
1980-01-01
Necessity for usage of geothermal heat pump
International Nuclear Information System (INIS)
Every day we are witnesses of constantly rapid increase of consumption of Electric energy in R. of Macedonia as so as in the other countries in all the world. This rapid increase of consumption of Electric energy independent of a lot of electrical units, which are applying in human life like: homes, administration and publication objects, as well as in industry. All of this conditions make us to thinking how is possible more rational consumption of electric energy in all areas in human life. One of the possible manners to reduce the consumption of electrical energy for heating and cooling is to use geothermal heat pumps. In this paper will be proposed geothermal heat pump, which is going to use the heat of earth by vertical and horizontal cupper pipe heat exchanger with data from-GHP (Geothermal Heat ...
2004-10-07
Feedwater control device for a reactor
International Nuclear Information System (INIS)
Purpose: To eliminate the water level deviation due to the recycling flowrate, as well as enable a stable control to a reference value even upon changes in the recycling flowrate caused by the variation in the opening degree of a minimum flow valve. Constitution: Reactor recycling system comprises a feedwater pump, a flowrate control valve, a reactor water level detector, and a minimum flow line and a minimum flow valve for preventing the overheating of the feedwater pump at a low flowrate. A flowrate compensator is further disposed, in which a recycling flowrate signal is subtracted from a pump flow rate signal and the result is fedback as a compensated pump flowrate signal. This enables the control system to operate at a rapid response for suppressing the effect of the recycling flowrate as external disturbance, whereby the water level in ...
1981-11-18
The feasibility of using a septic tank as a heat source for geothermal heat pumps
Energy Technology Data Exchange (ETDEWEB)
A geothermal heat pump (GHP) system with three ground coils was installed in a residence in northern Idaho with a portion of the ground heat exchanger wrapped around the residential septic tank. The septic coil provided a significant portion of the heating for the residence over the heating season. There was no evidence of the septic tank freezing up or failing to properly function. Utilizing a septic tank as a heat source for GHP systems is feasible design option if the septic tank is used on a full-time basis. However, the tank should be surrounded on all sides by a large amount of soil and/or insulated from the ground surface to ensure that ground temperatures near the tank remain warm during the winter.
1999-11-01
Design and Operation of a Novel Capillary Pumped Two-Loop System for Cooling of Electronic Devices
British Library Electronic Table of Contents (United Kingdom)
Heat pipes, loop heat pipes (LHP), and capillary pumped loops (CPL) have already proven their potential to remove high heat fluxes from a small electronic device and transport the heat to a heat sink that is large enough to transfer it into the ambient air. We introduce a novel two-loop system similar in design to CPLs but with an additional buoyancy-driven fluid loop. Non-degassed methanol is used as a working fluid. Key benefits compared to LHPs and CPLs are easy filling procedure, easy startup, and the tolerance toward noncondensable gases in the fluid. The amount of fluid in the system can be varied over a broad range without affecting the heat transfer performance. Three different inverted-meniscus-type evaporators have been employed in this study. A maximum evaporator heat transfer r...
2012-01-01
An Experimental study on a Method of Computing Minimum flow rate
International Nuclear Information System (INIS)
Many pump reliability problems in the Nuclear Power Plants (NPPs) are being attributed to the operation of the pump at flow rates well below its best efficiency point(BEP). Generally, the manufacturer and the user try to avert such problems by specifying a minimum flow, below which the pump should not be operated. Pump minimum flow usually involves two considerations. The first consideration is normally termed the 'thermal minimum flow', which is that flow required to prevent the fluid inside the pump from reaching saturation conditions. The other consideration is often referred to as 'mechanical minimum flow', which is that flow required to prevent mechanical damage. However, the criteria for specifying such a minimum flow are not clearly understood by all parties concerned. Also various factor and information for computing minimum flow are not easily available as considering for ...
2009-10-01
Benefit analysis and evaluation of pumped-storage plant in Taipower system
Energy Technology Data Exchange (ETDEWEB)
The operation of pumped-storage plants (PSP) is based on the daily load variations of power demand. It performs power generation at peak load times during the day, and pumps water up into the reservoir during the off-peak times at night. In the Taipower system in Taiwan, there are two pumped storage plants with ten units. These had a total installed capacity of 2,602 MW or a 12 percent capacity at the end of 1995. The plants were able to reduce system generation costs and improve reliability. A Pumped-Storage Plant Benefit Analysis (PSPBA) program was established using the principle of economic dispatch in 1985. This paper explains the rules of the program, the analysis results of the past 10 years, and a a cost benefit evaluation. It was found that the advantages of PSP are not only in supplying the power for peak load, but also in decreasing the total fuel cost. 5 figs., 4 refs.
1995-12-31
Control of the reduction/oxidation potential of Hanford Waste Vitrification Plant feeds
International Nuclear Information System (INIS)
A schematic diagram shows the various processing steps to be performed during feed preparation in the Hanford Waste Vitrification Plant (HWVP). The pretreated NCAW is transferred to the slurry receipt adjustment tank (SRAT) in the HWVP for concentration. Water removed during boildown is collected in the slurry mix evaporator condensate tank (SMECT). After waste treatment the water is returned to the storage tanks for eventual disposal. The pretreated Neutralized Current Acid Waste (NCAW) is concentrated in the SRAT to approximately 125 g waste oxides/ liter. Formic acid is then added at a controlled rate to improve rheological properties and achieve a required reduction/oxidation state. Reflux boiling is initiated and continued for several hours. The concentrated slurry is cooled and pumped to the slurry mix evaporator (SME). In the SME, glass frit is added, and the slurry is further concentrated to achieve a nominal ...
1988-09-11
Centrifugal potential energy : an astounding renewable energy concept
Energy Technology Data Exchange (ETDEWEB)
A new energy concept known as centrifugal potential energy was discussed. This new energy concept is capable of increasing the pressure, temperature and enthalpy of a fluid, without having to apply work or heat transfer to the fluid. It occurs through a change in the centrifugal potential energy of the flowing fluid in a rotating frame of reference or a centrifugal force field, where work is performed internally by the centrifugal weight of the fluid. This energy concept has resulted in new energy equations, such as the Rotational Frame Bernoulli's Equation for liquids and the Rotational Frame Steady-Flow Energy Equation for gases. Applications of these equations have been incorporated into the design of centrifugal field pumps and compressors. Rather than compressing a fluid with a physical load transfer, these devices can compress a fluid via the effect of centrifugal force applied to the object. A large amount of energy is therefore ...
2010-07-01
Energy Technology Data Exchange (ETDEWEB)
The generation of thermal energy is the great importance for the agribusiness of dairy industry to conservation the quality of milk, taking into account that the electricity is the main source currently used for the thermal energy input. The small agribusiness dairy industry currently practiced in Brazil faces several problems related to the cost of electricity and the distance of rural properties of networks of power. In the current scenario of Brazilian dairy production, there is need for the generation of cold for the milk cooling, and also the heat for the production of hot water around 50 deg C to 60 deg C and also for cleaning of equipment used for milk production and processing. The main objective of this study is the modeling and simulation of integrated recovery process of solid waste, effluents and bioconversion. The specific project objectives are: comparison study of options and technological routes of low cost material for power ...
2008-07-01
International Nuclear Information System (INIS)
Purpose: To remove excessive driving pressure applied to an unisolated control rod drive by returning excessive coolant to a condensed water storage tank or to the inlet side of a drive water pump using a coolant flow rate control pipe of a control rod driving hydraulic system. Constitution: Excessive water is returned to a condensed water tank while controlling the excessive coolant by a flow control valve in response to variations in the pressure difference between the reactor pressure and the driving water line when the control rods are isolated using a pipe from the outlet side of the drive water pump to the condensed water storage tank. Thus, the control rod to be isolated is prevented form being dropped. (Sekiya, K.).
Energy Technology Data Exchange (ETDEWEB)
This analysis defines and evaluates the surface water supply system from the existing J-13 well to the North Portal. This system includes the pipe running from J-13 to a proposed Booster Pump Station at the intersection of H Road and the North Portal access road. Contained herein is an analysis of the proposed Booster Pump Station with a brief description of the system that could be installed to the South Portal and the optional shaft. The tanks that supply the water to the North Portal are sized, and the supply system to the North Portal facilities and up to Topopah Spring North Ramp is defined.
1996-02-06
Energy Technology Data Exchange (ETDEWEB)
This report documents results of a preliminary hazard analysis (PHA) covering the existing Crane Chempump and the new salt well pumping design. Three hazardous conditions were identified for the Chempump and ten hazardous conditions were identified for the new salt well pump design. This report also presents the results of the control decision/allocation process. A backflow preventer and associated limiting condition for operation were assigned to one hazardous condition with the new design.
2000-11-16
Failure analyses and weld repair of boiler feed water pumps
Energy Technology Data Exchange (ETDEWEB)
During a regular inspection of the Boiler Auxiliaries at one of the Dutch Electricity Production Companies serious cracks were found in the cover and casings of the feed water circulation pumps in two units after 108.000 and 122.000 hours of boiler operation. Kema Laboratories carried out Failure analyses on boat samples at the cracked areas. Corrosion fatigue cracking was found on the inner side of the GS-24CrNiMo325 casing. Shop Weld repairs were carried out using a newly developed mechanized Plasma Welding Technique. The repaired feed water circulation pumps showed no problems alter several years of operation. The costs of repair were substantially lower than the costs of replacement. (orig.) 3 refs.
1998-12-31
Hybrid solution and pump-storage optimization in water supply system efficiency: A case study
International Nuclear Information System (INIS)
Environmental targets and saving energy have become ones of the world main concerns over the last years and it will increase and become more important in a near future. The world population growth rate is the major factor contributing for the increase in global pollution and energy and water consumption. In 2005, the world population was approximately 6.5 billion and this number is expected to reach 9 billion by 2050 [United Nations, 2008. (www.un.org), accessed on July]. Water supply systems use energy for pumping water, so new strategies must be developed and implemented in order to reduce this consumption. In addition, if there is excess of hydraulic energy in a water system, some type of water power generation can be implemented. This paper presents an optimization model that determines the best hourly operation for 1 day, according to the electricity ...
2008-11-01
Electrohydrodynamic pumping in cable pipes. Final report
Energy Technology Data Exchange (ETDEWEB)
Many oil-insulated electric power cables are limited by heat buildup caused in part by the low thermal conductivity of the oil. Circulation of the oil is known to reduce the cable temperature, but can lead to excessive pressure buildup on long cables when using conventional pumping methods. An alternate pumping method using distributed electric fields to avoid this pressure buildup is described. Electrohydrodynamic (EHD) pumping was studied both theoretically and experimentally for possible application in underground cable cooling. Theoretical studies included both analytical and finite-element analysis of the flow patterns driven by travelling electric fields. Experimentally, flow rates in a cable-pipe model were measured under a wide variety of operating conditions. Theory and experiment are in agreement for velocities below 10 cm/s, but higher velocities could not be reached in the experiment, due to ...
1983-02-01
Reliability assessment of hydrothermal generation systems containing pumped storage plant
Energy Technology Data Exchange (ETDEWEB)
Previous models and evaluation techniques based on the Monte Carlo simulation for the reliability assessment of mixed hydrothermal generation systems are extended. Models for reservoirs on multiple rivers and pumped storage plants are developed. Operating and water management policies are extended to include the relative economical effects of operating alternative sources of generation. These effects and the benefits are described and discussed using an extended IEEE reliability test system. (Author).
1991-11-01
Geothermal Heat Pump research and development studies at Sandia National Laboratories
Energy Technology Data Exchange (ETDEWEB)
The Geothermal Heat Pump (GHP) concept was originally developed in the 1940`s. Recently, because of increasing energy costs, utility interest, and the development of simple and durable ground source heat exchangers, GHP`s have gained international attention as a proven means of energy conservation and electrical peak power demand reduction. GHP systems require installation of a buried heat exchanger to utilize the nearly constant ground temperature making them more efficient than conventional air source heat pumps. However, the high installation cost for both residential and commercial applications is a major obstacle to their market penetration. Sandia National Laboratories (SNL) through its sponsors, the Department of Energy (DOE), and the Department of Defense (DOD), has embarked on a research program to find ways to reduce GHP installation costs and improve ...
1994-08-01
Supporting Thermal Hydraulic Calculations for the SGTR Event Tree of SMART Level 1 PSA
International Nuclear Information System (INIS)
SMART (System integrated Modular Advanced ReacTor) , is under development at the Korea Atomic Energy Research Institute (KAERI). SMART is an integral type pressurized water reactor which contains a pressurizer, 4 reactor coolant pumps (RCPs), and 8 steam generator cassettes(S/Gs) in a single reactor vessel. This reactor has substantially enhanced its safety with an integral layout of its major components, 4 trains of safety injection system (SIS), and an adoption of 4 trains of passive residual heat removal system (PRHRS) instead of an active auxiliary feedwater system . The thermal power is 330 MWth. During the conceptual design stage, a preliminary PSA was performed. PSA results identified that a steam generator tube rupture (SGTR) is one of the most important initiating events which results in a high core damage frequency. Clear understanding of accident progression with various combinations of the safety systems helps ...
2010-10-01
Pumps and compressors - buyers` guide 1996/`97; Pumpen und Kompressoren - Einkaufsfuehrer 1996/97
Energy Technology Data Exchange (ETDEWEB)
The 1996/`97 buyers` guide comprises ten chapters: 1. List of suppliers; 2. Waste management, effluents, sewage systems; 3. Water supply, hydroengineering; 4. Chemistry, petrochemistry; 5. Chemical engineering; 6. Food industry, biotechnology; 7. Paper and cellulose industry; 8. Natural gas industry, natural gas supply; 9. Power plant engineering, power systems, district heating; 10. Air conditioning and refrigeration engineering. (orig.) [Deutsch] Der vorliegende Einkaufsfuehrer 1996/97 ist in zehn Kapiteln gegliedert. Diese sind: 1. Firmenverzeichnis 2-11 2. Entsorgungs-/Abwassertechnik, Klaeranlagen 12-15 3. Wasserversorgung, Wassertechnik 16-18 4. Chemie, Petrochemie 19-22 5. Verfahrenstechnik 23-26 6. Lebensmittelindustrie, Biotechnik 27-29 7. Papier-, Zeluloseindustrie 30-31 8. Erdgasindustrie, -versorgung 32 9. Kraftwerkstechnik, Energieanlagen, Fernwaerme 33-34 10. Kaelte-/Klimatechnik 35-36. (orig.)
1996-12-01
Energy Technology Data Exchange (ETDEWEB)
Modern tubular type pumps commonly have lubricated radial bearings which require no compressed water supply and reduce the servicing requirements. Problems that may possibly result from entrained sand in the pumped fluid were solved with the development of ceramic Residur {sup trademark} bearngs in the early eighties. (orig.) [German] In zunehmendem Masse werden Rohrgehaeusepumpen mit foerdermediumgeschmierten Radiallagern ausgestattet, da dies z.B. neben dem Wegfall einer ansonsten notwendigen Druckwasserversorgung auch einen deutlichen reduzierten Wartungsaufwand nach sich zieht. Den Problemen durch eine moegliche Sandbeladung des Foerdermedium wurde bereits durch die Entwicklung der keramischen Residur {sup trademark} -Lager Anfang der 80er Jahre Rechnung getragen. (orig.)
1998-07-01
Larger geothermal heat pump plants in the central region of Germany
Energy Technology Data Exchange (ETDEWEB)
In recent years, several larger geothermal heat pump plants for offices or commercial areas have been designed and built in the central region of Germany, mainly in the Rhein-Main area. Systems with borehole heat exchangers (BHE; in the USA the term Vertical Loop is commonly used) as well as with shallow geothermal doublets (groundwater wells) are operational. New solutions had to be found to adapt the technology to certain site constraints, and innovative components such as thermally-enhanced grouting material have been used. This paper reviews the early development of Ground Source Heat Pumps (GSHP) for commercial buildings, gives details on a number of recent plants and discusses problems that arose during their realisation: UEG Wetzlar, a building with chemical laboratories and one of the first examples of direct cooling from BHE; DFS Langen (German Air Traffic Control ...
2003-12-01
International Nuclear Information System (INIS)
Norway is a member of Annex 29, 'Ground-Source Heat Pump Systems Overcoming Technical and Market Barriers' (2004-2006), organized under the umbrella of the International Energy Agency (IEA) and the IEA Heat Pump Programme (HPP). The 7 participating countries are Austria (Operating Agent), Canada, Japan, Norway, Spain, Sweden and the USA. The Norwegian participation is financed by ENOVA SF, and SINTEF Energy Research is responsible for planning and carrying out the Norwegian activities. This report provides a status for ground-source heat pump (GSHP) systems in Norway with regard to state-of-the-art technology, installation examples, geological data, costs and market opportunities. A Norwegian Internet home page for ground-source heat pump systems (www.energy.sintef.no/prosjekt/Annex29) is also presented. GSHP systems in ...
Thermal gradient humidification-dehumidification desalination system
Energy Technology Data Exchange (ETDEWEB)
A solar energy desalination process utilizing solar radiation directly for the evaporation of salt water is described. Ambient air takes on water vapor as the air passes through an evaporative medium. It is then directed between a saline water-covered, solar absorbing surface and a solar collecting housing. The resulting heated and moisture-saturated air is cooled in a heat exchange means where condensation of fresh water occurs. Simultaneously, cool salt water is utilized as the cooling water in the heat exchange means, and takes on the heat of condensation given up by the condensing vapor. The heated salt water from the heat exchange means is partially directed over the solar absorbing surface, and at least a ...
1982-12-14
International Space Station Overview - NASA
(accumulates & stores brine for disposal). Separator. (separates water from purge gases). ? Purge pump periodically vent ... Reactor Health. Sensor. ( verifies reactor is operating w/n limits) ... Waste and Hygiene Compartment ...
...Filter gaskets and seatings; (4) Pumps; (5) Solvent tanks and containers; (6) Water separators; (7) Muck cookers; (8) Stills; (9) Exhaust dampers; (10) Diverter valves; and (11) All Filter housings. (l)...
2009-07-01
Energy Technology Data Exchange (ETDEWEB)
The paper is concerned with the economic operation of power systems comprising pumped storage and thermal plants. In power systems, pumped storage plants may receive the energy required for pumping water either from the system in which they are integrated or from a neighbouring system. Therefore, two mathematical formulations of the problem are presented depending on the source of energy during pumping. In both cases, the problem is reduced to a non linear optimization problem. Two numerical techniques are suggested for the solution of this optimization problem, namely the Lagrangian Multipliers technique and the Rosen Gradient Projection technique. Numerical examples are presented to demonstrate the techniques. Although the Lagrangian Multipliers technique has the advantage of being a well known technique, however, computer wise, the Rosen Gradient Projection technique proves to be ...
1980-12-01
Hitch code capabilities for modeling AVT chemistry
International Nuclear Information System (INIS)
Several types of corrosion have damaged alloy 600 tubing in the secondary side of steam generators. The types of corrosion include wastage, denting, intergranular attack, stress corrosion, erosion-corrosion, etc. The environments which cause attack may originate from leaks of cooling water into the condensate, etc. When the contaminated feedwater is pumped into the generator, the impurities may concentrate first 200 to 400 fold in the bulk water, depending on the blowdown, and then further to saturation and dryness in heated tube support plate crevices. Characterization of local solution chemistries is the first step to predict and correct the type of corrosion that can occur. The pH is of particular importance because it is a major factor governing the rate of corrosion reactions. The pH of a solution at high temperature is not the same as the ambient temperature, since ionic dissociation constants, ...
1985-03-01
The formation of todorokite and birnessite in sea water pumped from under ground
Manganese oxides precipitated from aerated well sea water at the Marine Science Museum, Tokai University, have been analyzed chemically and mineralogically. The O / Mn ratios are lower in todorokite than in birnessite but these minerals have similar contents of minor transition metals, which can be taken up additionally from sea water after the precipitation of Mn oxides. On the basis of these results, the genesis of Mn minerals is discussed in relation to marine Mn nodules.
1984-05-01
Heating and hot water: the installations; Chauffage et eau chaude: les installations
Energy Technology Data Exchange (ETDEWEB)
This book brings recommendations and information on the choice and the operating of heating systems and domestic hot water production in order to better choose the house, to better use the heating and to preserve the environment. General notions on the different heating systems and their operating on the renewable energies used and the heating emitters offer advices for the purchase of a house. (A.L.B.)
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
The effect of heat transfer is described from heat exchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heat exchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heat exchange tubes neqlecting the changes of physical properties of water along the heat exchange tubes, will yield sufficiently accurate results.
1982-10-01
International Nuclear Information System (INIS)
The effect of heat transfer is described from heat exchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heat exchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heat exchange tubes neqlecting the changes of physical properties of water along the heat exchange tubes, will yield sufficiently accurate results. (author).
1982-01-01
Energy Technology Data Exchange (ETDEWEB)
Heat pumps for residential space heating become an increasingly important alternative to the conventional heating system like gas or oil burner. They offer the opportunity to reduce CO{sub 2} emission associated with heating residential homes in Germany. High compressors efficiency and a wide operating map are required so that an economically viable heat pumps is achieved which meets the operational conditions for present and future heating systems. The design parameter of existing heating systems require relatively high condensing temperatures which can be achieved with dedicated compressor designs. The design of Scroll compressors specially adapted to these heat pumps is shown and their operation is explained. (orig.) [German] Waermepumpen fuer die ...
2003-07-01
Energy Technology Data Exchange (ETDEWEB)
Ground-water monitoring near the Raft River site was initiated in 1974 by the IDWR. This effort consisted of semiannual chemical sampling of 22 irrigation wells near the Raft River geothermal development area. This program yielded useful baseline chemical data; however, several problems were inherent. For example, access to water pumped from the wells is limited to the irrigation season (April through September). All the wells are not continuously pumped; thus, some wells that are sampled one season cannot be sampled the next. In addition, information on well construction, completion, and production is often unreliable or not available. These data are to be supplemented by establishing a series of monitor wells in the proposed geothermal withdrawal and injection area. These wells were to be located and designed to provide data necessary for evaluating and predicting the impact of geothermal development ...
1982-09-01
Energy Technology Data Exchange (ETDEWEB)
Conference paper regarding research in the use of freeze prevention for passive solar domestic water heating systems.
2006-05-01
Theoretical and basic experimental analysis on load adjustment of geothermal heat pump systems
Energy Technology Data Exchange (ETDEWEB)
In order to match the output capacity of a geothermal heat pump system (GHPS) with the actual load requirement, research has been conducted in searching for suitable adjusting methods for the GHPS and on the subsequent effects on the working parameters of the GHPS. Firstly, several methods are compared, and it is found that the method of adjusting the compressor's rotation speed using a transducer is better than the others. Secondly, this method is experimented on a small scale GHPS at frequencies ranging from 30 to 55 Hz. The analysis of the experimental data reveals the relationships between the compressor frequency and other important parameters, such as coefficient of performance, heat capacity, cool capacity and compressor power input. The conclusions in the paper can serve as some guidance to the load adjustment of GHPS. (Author)
2003-01-01
Energy Technology Data Exchange (ETDEWEB)
Preliminary studies were preformed to determine whether thermal conductivity of cementitious grouts used to backfill heat exchanger loops for geothermal heat pumps could be improved, thus improving efficiency. Grouts containing selected additives were compares with conventional bentonite and cement grouts. Significant enhancement of grout alumina grit, steel fibers, and silicon carbide increased the thermal conductivity when compared to unfilled, high solids bentonite grouts and conventional cement grouts. Furthermore, the developed grouts retained high thermal conductivity in the dry state, where as conventional bentonite and cement grouts tend to act as insulators if moisture is lost. The cementitious grouts studied can be mixed and placed using conventional grouting equipment.
1996-06-01
Local analysis of three-dimensional air cooled condenser using a two-phase flow diagram
Energy Technology Data Exchange (ETDEWEB)
This paper is concerned with the development and application of an analytical method for the performance prediction of air cooled condensers. A local analysis is employed in which the condenser is considered as a matrix of small basic heat transfer modules. For each element, local film coefficients for both the air and the condensing fluid are determined according to the existing local conditions, including the two-phase flow regime. The paper considers an application of the method to heat pump condensing.
1983-07-01
RF effects on current-driven plasma instabilities
Energy Technology Data Exchange (ETDEWEB)
The Versatile Toroidal Facility (VTF) is a large laboratory plasma machine of 1 meter major radius used to carry out investigations of ionospheric plasma turbulence. Spectral analysis has been performed on plasmas produced by the electron emitters. Interest has focused on the low frequencies below the lower hybrid resonance where ion acoustic and current-convective modes have been observed. Microwaves injected from a 3,000 watt magnetron produce dramatic changes to the low frequency spectrum. First, the parametric decay instability intensifies the ion acoustic modes in the region of plasma heated by the microwaves. Second, the normally dominant current-convective modes are greatly suppressed in the heated region due to the oscillating electric field of the pump wave. When the authors probe beyond the heated region, these two pump wave effects are no longer observed, presumably ...
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one, reported in Volume 1, dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of entrance and exit chambers for the cooling oil. The second major ...
1981-05-01
Manitoba Hydro's earth power program and Manitoba market update
International Nuclear Information System (INIS)
An outline of Manitoba Hydro's Earth Power program was presented. Details of the heat pump market in Manitoba were provided, including details of residential and commercial sales. Total residential heat pump sales amounted to 577 units in 2004, equivalent to over $11.2 million in sales. Commercial installations amounted to approximately $12.7 million. An outline of industry players was presented. The goals of Manitoba Hydro were outlined in relation to geothermal energy and the Power Smart program. Their objectives included increasing awareness of geothermal energy, making heat pumps more accessible, and improving industry infrastructure. Other objectives included educating the public about life-cycle cost implications, residential loans and commercial incentives. To date, the residential power loan has provided financing to over 300 Manitoba home owners for ...
2005-02-24
Energy Technology Data Exchange (ETDEWEB)
In an electromagnetic pump of the present invention for use in circulation of coolants in an LMFBR type reactor, the outer circumference of coil conductors is covered by an insulator retaining cover, and powdery or granular insulator is filled between the coil conductors and the insulator retaining cover. Upon reaching high temperature, elongation of the coil conductors by heat expansion is absorbed by movement of the particles of the powdery insulator thereby preventing excess stresses from exerting on the coil insulator constituted with the insulator retaining cover and the powdery or granular insulator and preventing generation of crackings on the coil insulator. Thus, plant stability is improved. (N.H.).
1994-05-13
Recovering heat from the cupola stack
Energy Technology Data Exchange (ETDEWEB)
A brief survey is given of some ways in which heat, which would normally be lost from a cupola furnace, is being recovered, either as hot water, steam, or electricity. Examples are provided of heat-recovery systems in Germany, Italy, and America. (author).
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
This report contains a set of nomographs which can be used to estimate the average annual solar fraction for solar space and water heating at a large number of DOD facilities. The solar fraction estimated from the nomograph is in close agreement with F-Chart 3.0 and allows for variation of the following parameters: annual load, collector area, collector transmittance-absorptance coefficient, and collector overall loss coefficient.
1982-09-01
Evaluation of heat exchange rate of GHE in geothermal heat pump systems
Energy Technology Data Exchange (ETDEWEB)
Total thermal resistance of ground heat exchanger (GHE) is comprised of that of the soil and inside the borehole. The thermal resistance of soil can be calculated using the linear source theory and cylindrical source theory, while that inside the borehole is more complicated due to the integrated resistance of fluid convection, and the conduction through pipe and grout. Present study evaluates heat exchange rate per depth of GHE by calculating the total thermal resistance, and compares different methods to analyze their similarities and differences for engineering applications. The effects of seven separate factors, running time, shank spacing, depth of borehole, velocity in the pipe, thermal conductivity of grout, inlet temperature and soil type, on the thermal resistance and heat exchange rate are analyzed. Experimental data from several real geothermal heat pump (GHP) ...
2009-12-15
Energy Technology Data Exchange (ETDEWEB)
An analytical study of the ice-formation process associated with heat-conducting plates located perpendicularly to isothermally heated and cooled surfaces with some clearance is presented. It is proposed that the onset conditions, which describe whether the ice-volume fraction in a steady state is greater than or less than that without heat-conducting plates, are defined by the dimensionless distances between the heated/cooled walls and the heat-conducting plates. It is shown that the onset conditions are dependent on the pitch and the thickness of the heat-conducting plates and are less dependent on the thermal conductivity of the plates.
1994-07-01
Energy conservation by means of integrated systems; Beter resultaat door klimaatkwartet
Energy Technology Data Exchange (ETDEWEB)
Air conditioning is getting maximum attention these days when building new offices. For the new office building of the assurance company Zwitserleven in Amstelveen, Netherlands, a new air conditioning concept is applied, based on four existing air conditioning methods: cold storage and heat storage in the soil, heat pump, double-wall facades with integrated climate control, and radiant heating combined with a cooling system in the ceiling. The integration of these methods not only provides complete climate comfort for the employees but also substantial energy savings. 3 figs.,1 ills.
1995-11-01
The Philadelphia Marriott: A convention center flagship hotel
Energy Technology Data Exchange (ETDEWEB)
This article describes the state-of-the-art HVAC system at the Philadelphia Marriott Hotel. Thermal comfort and indoor air quality are emphasized. The system uses a hybrid gas absorption/electric centrifugal chilled water plant, variable flow pumping, water-side economizers to provide free cooling, central air handling units with air-side economizers and flow monitoring equipment.
1997-01-01
International water power and dam construction yearbook 1996
Energy Technology Data Exchange (ETDEWEB)
This document draws together data on hydroelectric power generation and dam construction for 1996. Machinery such as turbines and hydroelectric generators are listed together with their manufacturers. Contact addresses for international organizations concerned with water power are listed. Listings are also given for hydro resources worldwide, and the global distribution of pumped-storage plants, dams and hydroelectric plants. Company data is also listed providing a buyer`s guide for 1996. (UK)
1996-12-31
A method for isolating a water influx into a well
Energy Technology Data Exchange (ETDEWEB)
The goal of the invention is to increase the effectiveness of the isolation process through increasing the waterproofing of the stratum. The cited goal is achieved by isolating water influx into a well through introduction of a chemical reagent into the stratum. To interact with the stratum, an alloy of titanium and iron is introduced into the stratum as the chemical reagent with subsequent pumping of hydrogen into the stratum at 100 to 200C.
1983-01-01
Recovery of Water from Boiler Flue Gas
Energy Technology Data Exchange (ETDEWEB)
This project dealt with use of condensing heat exchangers to recover water vapor from flue gas at coal-fired power plants. Pilot-scale heat transfer tests were performed to determine the relationship between flue gas moisture concentration, heat exchanger design and operating conditions, and water vapor condensation rate. The tests also determined the extent to which the condensation processes for water and acid vapors in flue gas can be made to occur separately in different heat transfer sections. The results showed flue gas water vapor condensed in the low temperature region of the heat exchanger system, with water capture efficiencies depending strongly on flue gas moisture content, cooling water inlet temperature, heat exchanger ...
2008-09-30
Energy Technology Data Exchange (ETDEWEB)
Organic Rankine cycles (ORC) have unique properties that are well suited to solar power generation. In this work design and performance calculations are performed using MatLab/SimuLink computational environment. The cycle consists of thermal solar collectors (Flat Plate Solar Collector (FPC), or Parabolic Trough Collector (PTC), or Compound Parabolic Concentrator (CPC)) for heat input, expansion turbine for work output, condenser unit for heat rejection, pump unit, and Reverse Osmosis (RO) unit. Reverse osmosis unit specifications used in this work is based on Sharm El-Shiekh RO desalination plant. Different working fluids such as: butane, isobutane, propane, R134a, R152a, R245ca, and R245fa are examined for FPC. R113, R123, hexane, and pentane are investigated for CPC. Dodecane, nonane, octane, and toluene are allocated for PTC. The proposed process units are modeled and show a good validity with literatures. Exergy and ...
2010-11-15
On the water-chemical regime in steam generators at NPP
British Library Electronic Table of Contents (United Kingdom)
The effect of the water-chemical regime (WCR) on damage sustained by heating surfaces of steam generators at NPP is analyzed. It is indicated that phosphate treatment with minimal excesses of phosphates in the steamgenerator water is the most optimal method of managing the WCR regime of horizontal steam generators.
2006-01-01
Heat-transfer analysis of the plum brook reactor - NASA Technical ...
average bulk water temper ature rise, OF bulk water temperature at elevation z, OF bulk water temperature in channels 0 and 1, O F film temperature, OF ...
Condensation heat transfer in a steam-water stratified flow
Energy Technology Data Exchange (ETDEWEB)
Fundamental phenomena of condensation heat transfer at a steam-water interface have been studied related to the thermo-hydrodynamics of the emergency core cooling system for light water reactors. In this study temperature fluctuations near the interface and in the liquid phase were measured using fine thermocouples for a saturated steam-subcooled water co-current stratified two-phase flow in a nearly horizontal rectangular channel, and heat transfer coefficients were determined experimentally. The values of the condensation heat transfer coefficients in this experiment are from 6 to 40 kW/m{sup 2}K. In the regions of high Reynolds numbers, as the steam Reynolds numbers become larger, the average interfacial heat transfer coefficients tend to increase. The corelations of Nusselt numbers were obtained from the heat ...
1999-07-01
Condensation heat transfer in a steam-water stratified flow
International Nuclear Information System (INIS)
Fundamental phenomena of condensation heat transfer at a steam-water interface have been studied related to the thermo-hydrodynamics of the emergency core cooling system for light water reactors. In this study temperature fluctuations near the interface and in the liquid phase were measured using fine thermocouples for a saturated steam-subcooled water co-current stratified two-phase flow in a nearly horizontal rectangular channel, and heat transfer coefficients were determined experimentally. The values of the condensation heat transfer coefficients in this experiment are from 6 to 40 kW/m"2K. In the regions of high Reynolds numbers, as the steam Reynolds numbers become larger, the average interfacial heat transfer coefficients tend to increase. The corelations of Nusselt numbers were obtained from the heat transfer ...
1999-04-19
Energy Technology Data Exchange (ETDEWEB)
Forced convection boiling of subcooled water was performed in a horizontal rectangular channel with heated surface on the bottom. The experiment was conducted for heating surfaces, 10 mm, 20 mm and 40mm in length. Microbubble Emission Boiling, MEB, was observed in subcooled transition boiling and easy to be generated for the shorter heating surfaces. In higher flow velocity of subcooled water, MEB was generated at even lower subcooling. Stormy MEB was observed at both the higher subcooling and the higher flow velocity of water. In the stormy MEB, the heat flux rose up rapidly above CHF (Critical Heat Flux) with larger acoustic noise and vibration. (author)
1999-09-25
Improvement of the PGV-1000 steam generator in-vessel components
International Nuclear Information System (INIS)
Results of calculational investigations into circulation of water and steam-and-water mixture in the PGV-1000 steam generator heat exchanger bundle used at NPPs with the WWER-1000 reactors, are considered. Model of water circulation in horizontal steam generator with submerged heating surface under conditions of steam generation irregularity along the heat transfer tubes is made. On the basis of the obtained data the assumption is made about water essential overflows from the hot collector zone into the cold one. Overflow rate over the upper line of the heat transfer tubes may constitute 0.7 m/s. The conclusion is made about the necessity to set up the vertical barrier which divides hot and cold sections of heat transfer tubes and helps to avoid water transverse overflows.
1988-01-01
Energy Technology Data Exchange (ETDEWEB)
Because power requirements in induction heating applications are largely dependent on the physical properties of the product to be heated, inducting, heating is mainly used in steelwork applications, for the manufacture of finished or semi-finished parts. Applications here cover five main types of steelworks operation: smelting, heating prior to forming, heat treatment, surface treatment, and assembly process. At the same time, technological progress has opened up innovative applications in sectors such as chemical and agro-food industries. Other emerging applications for induction include direct forming of liquid metal, wholly or partially replacing mechanical transformations on solid metal. Techniques include electromagnetic forming, continuous cold-crucible casting, electromagnetic mixing, flow control by continuous magnetic field, and production of intense sliding fields ...
2004-05-01
Heat transfer augmentation in an axisymmetric impinging jet
This paper presents the experimental results of heat transfer augmentation in an axisymmetric jet impinging normally on a flat plate surface without the requirement of additional pumping power. The present technique of augmentation utilizes only a punched plate with circular holes arranged in a triangular array, fixed parallel to, just in front of the heated target plate. Near the optimum conditions determined, the heat transfer coefficient at the geometrical stagnation point can be increased 4 times. Additional flow visualization study indicates that this augmentation mechanism creates an improved flow field where the punched plate acts as a detached fin, the conductivity of which may be exploited for further augmentation. Besides augmentation, the present investigation foresees the possibility of manipulating the distribution of local heat transfer rate by varying few parameters.
1982-01-01
Energy Technology Data Exchange (ETDEWEB)
Before the implementation Water Framework directive, it was usual to forget that a good environment protection of the receiving waters needs a correct and coordinated operation of the subsystems of the water cycle, specially sewerage system, WWTP and receiving waters. This explains that most of the countries have focused their efforts in the treatment of dry weather flows forgetting the management of wet weather flows. Actually the idea that a sewerage system or a WWTP can not be planned or managed independently without considering the effects on the receiving waters is commonly accepted because not only each one of these systems must work correctly but also it is required a minimum impact in the receiving waters of the sewerage and WWTP overflows in dry and wet weather. All these links will affect the management strategy of the sewerage system (storm ...
2005-07-01
Thermo-economic analysis of solar powered adsorption heat pump
British Library Electronic Table of Contents (United Kingdom)
The economic feasibility of the residential solar thermal (ST) cooling system designed in the companion article [1] is ascertained by comparing it with a solar electric (SE) cooling system, and also with the baseline (i.e., control case), a grid dependent, highest efficiency COPC=5.66 heat pump. The economic scenario is analyzed for 24 cities across the southern USA, south of the 37degreeN. The SE cooling system provides lifecycle (20 year) savings to the homeowner only where electric rates are high and it is heavily subsidized. The overall societal effect (sum of taxpayer funded rebate and homeowner savings) is actually an increased cost everywhere except the California Central Valley, where the net savings is $1500. In the same valley, The ST cooling system provides greater lifecycle sav...
2007-01-01
Mold heating and cooling microprocessor conversion. Final report
Energy Technology Data Exchange (ETDEWEB)
Conversion of the microprocessors and software for the Mold Heating and Cooling (MHAC) pump package control systems was initiated to allow required system enhancements and provide data communications capabilities with the Plastics Information and Control System (PICS). The existing microprocessor-based control systems for the pump packages use an Intel 8088-based microprocessor board with a maximum of 64 Kbytes of program memory. The requirements for the system conversion were developed, and hardware has been selected to allow maximum reuse of existing hardware and software while providing the required additional capabilities and capacity. The new hardware will incorporate an Intel 80286-based microprocessor board with an 80287 math coprocessor, the system includes additional memory, I/O, and RS232 communication ports.
1995-07-01
A study of binary mixture boiling: boiling site density and subcooled heat transfer
Energy Technology Data Exchange (ETDEWEB)
(Boiling site densities and heat-transfer coefficients have been measured for ethanol-water and ethanol-benzene mixtures at 1.01 bar for a heated vertical brass disk. A strong effect of composition on the boiling site density was observed, which was attributed to the nature of the activation of the boiling surface and mass diffusion effects. The boiling heat-transfer coefficient was found to decrease with increasin subcooling, but for the mixtures at a given level of subcooling the decrease was less than that for the single components and azeotropic mixtures.) The heat-transfer coefficient at a given heat flux was seen to be quite insensitive to the very large increase in boiling site density in comparing the pure water and the ethanol-water azeotrope results, leading one to question pool boiling models that predict ...
1985-05-01
Performance analysis on a hybrid air-conditioning system of a green building
Energy Technology Data Exchange (ETDEWEB)
This paper presents the performance analysis on a hybrid air-conditioning system according to the hybrid building energy system of the green building demonstration project in Shanghai, in which a 150 m{sup 2} solar collector is used to power two 10 kW adsorption chillers, a vapor compression heat pump is used to cool air in the evaporating end while the condensing heating at about 80{sup o}C is fully used to regenerate a liquid desiccant dehumidification system. In the hybrid system, the sensible cooling to the air is treated mainly by solar adsorption cooling and vapor compression cooling, whereas the latent heat is treated by the liquid desiccant dehumidification system with regeneration from the condensing heat of the heat pump. The results show that the performance of this system is 44.5% higher than conventional vapor compression system ...
2006-05-15
British Library Electronic Table of Contents (United Kingdom)
In this paper we provide a geochemical investigation on 34 groundwater samples in the Mt. Vulture volcanic aquifer representing one of the most important groundwater resources of the southern Italy pumped for drinking and irrigation supply. The present study includes the first data on the abundance and mobility of minor and trace elements and the thermodynamic considerations on water-rock interaction processes in order to evaluate the conditions of alkali basalt weathering by waters enriched in magma-derived CO2. The results highlight the occurrence of two hydrofacies: bicarbonate alkaline-earth and alkaline waters deriving from low-temperature leaching of volcanic rocks of Mt. Vulture, and bicarbonate-sulfate-alkaline waters (high-salinity waters) related to prolonged water circulation in...
2011-01-01
Isolation condenser passive cooling of a nuclear reactor containment
Energy Technology Data Exchange (ETDEWEB)
This patent describes a nuclear system comprising a containment airspace in which a nuclear reactor pressure vessel is disposed there being a reactor core within the pressure vessel. It comprises a heat exchanger elevated a distance above the pressure vessel; a pool of water surrounding the heat exchanger; means for venting the pool of water to an environment outside the containment; a heat exchanger entry conduit within the containment, the entry conduit having an open lower end communicating with the containment space, and an upper end connected to the heat exchanger, water-containing heated fluid present in the containment airspace incident a pressure vessel loss of coolant event entering and flowing through the entry conduit into the heat exchanger for cooling the fluid to convert ...
1991-10-22
A mathematical model for simulating shallow solar ponds for treatment of industrial wastewater
Energy Technology Data Exchange (ETDEWEB)
This paper presents a mathematical model to analyze the solar evaporation in a shallow pond in steady state, when the inlet flow rate, concentration, surface area and solar radiation are given. The simultaneous heat and mass transfer mechanisms are considered for quantifying the amount of evaporated water to the atmosphere and the actual absorbed heat by wastewater is calculated to obtain the bottom temperature of water pond. The heat losses to air by radiation and convection mechanisms are considered and the heat transmission across the water film is evaluated by the forced convection mechanism. 6 refs., 5 figs., 1 tab.
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
The river Saale cascade consists of seven reservoirs with a total capacity of approx. 415 Mio. m[sup 3]. The entire reservoir system covers a catchment area of 1665 km[sup 2]. The water management tasks extend to the following main fields: flood protection upkeep of minimum water stock, salt load control and power generation. The energy supply capacity of the cascade is mainly used by pumped storage plants. The last of these plants, Hohenwarte II, was put into service in 1963. (orig.)
1993-01-01
The SBWR (simplified boiling water reactor) thermal-hydraulic performance analysis and testing
Utility interest has recently increased in potential future nuclear units that combine the characteristics of smaller size, greater simplicity, and more passive safety features. In response to such interest, General Electric (GE) began development in 1982 of a 600-MW(electric) reactor with simplified power generation and safety systems. This paper provides an overview of the simplified boiling water reactor (SBWR) design, with emphasis on the thermal-hydraulic aspects of the design. The SBWR is a natural circulation reactor requiring no pumps to circulate the water through the core.
1989-11-01
AquaMagna Water Conditioner and Descaler
...AquaMagna Water Conditioner and Descaler OCETA Environmental Technology & Business Profiles AQUAMAGNA WATER CONDITIONER AND DESCALER CAT. #03-018 CONTACT: Magna-Tek ...removal high-strength ceramic magnet no energy input The AquaMagna Water Conditioner and Descaler is a non-chemical method of water treatment. The technology uses ... Figure 1: The AquaMagna Water Conditioner and Descaler PROCESS/ PRODUCT APPLICATION: hard water domestic water process water reverse osmosis heat exchangers cooling ... For once-through or recirculating heating or cooling equipment, the AquaMagna descaler improves thermal efficiencies and reduces downtime. Figure 2 illustrates a cross-section ...
Energy Technology Data Exchange (ETDEWEB)
A cooling system for rejecting waste heat consists of a cooling tower incorporating a plurality of coolant tubes provided with cooling fins and each having a plurality of cooling channels therein, means for directing a heat exchange fluid from the power plant through less than the total number of cooling channels to cool the heat exchange fluid under normal ambient temperature conditions, means for directing water through the remaining cooling channels whenever the ambient temperature rises above the temperature at which dry cooling of the heat exchange fluid is sufficient and means for cooling the water. 5 figs.
1980-01-22
High concentration low wattage solar arrays and their applications
Energy Technology Data Exchange (ETDEWEB)
Midway Labs currently produces a 335x concentrator module that has reached as high as 19{percent} active area efficiency in production. The current production module uses the single crystal silicon back contact SunPower cell. The National Renewable Energy Lab has developed a multi junction cell using GalnP/GaAs technologies. The high efficiency ({gt}30{percent}) and high cell voltage offer an opportunity for Midway Labs to develop a tracking concentrator module that will provide 24 volts in the 140 to 160 watt range. This voltage and wattage range is applicable to a range of small scale water pumping applications that make up the bulk of water pumping solar panel sales. {copyright} {ital 1997 American Institute of Physics.}
1997-02-01
Energy Technology Data Exchange (ETDEWEB)
A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one reported in this volume dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of entrance and exit chambers for the cooling oil. The second major ...
1981-05-01
International Nuclear Information System (INIS)
A comparative assessment of five different heat transfer configurations for operation in compact heat exchangers is presented. The configurations under consideration are four standaed heat exchanger surfaces - two plain fin, an offset strip and a louvered fin geometry - and one surface with so called vortex generators for heat transfer augmentation. In the case of the standard surfaces, the basic performance characteristics in the form of heat transfer and friction data versus the Reynolds number have been taken from published experimental results. In the case of the vortex generator surface, the performance characteristics have been derived from a numerical prediction of the flow and temperature field in a closely spaced parallel plate channel with vortex generators in the form of delta wings mounted on the channel walls. In comparison to the plain fin surfaces with a rectangular ...
1993-01-01
Energy Technology Data Exchange (ETDEWEB)
A set of nomographs is presented which can be used to estimate the average annual solar fraction for solar space and water heating at a large number of DOD facilities. The solar fraction estimated from the nomograph is in close agreement with F-Chart 3.0 and allows for variation of the following parameters: annual load, collector area, collector transmittance-absorptance coefficient, and collector overall loss coefficient.
1982-09-01
Effect of ultrasonic waves on boiling heat transfer. 2
International Nuclear Information System (INIS)
This report focuses on a better understanding of the physical phenomenon related to the enhancement of boiling and non-boiling heat transfer by applying ultrasonic waves. Experimental results obtained both in a pool of water and in a vertically upward water flow proved clearly that macroscopic acoustic steam induced by ultrasonics is a major contribution to heat transfer augmentation. (author).
1993-05-01
Effect of ultrasonic waves on boiling heat transfer
Energy Technology Data Exchange (ETDEWEB)
This report focuses on a better understanding of the physical phenomenon related to the enhancement of boiling and non-boiling heat transfer by applying ultrasonic waves. Experimental results obtained both in a pool of water and in a vertically upward water flow proved clearly that macroscopic acoustic stream induced by ultrasonics is a major contribution to heat transfer augmentation. (author).
1993-07-01
Test-bed for compact ventilation units; Pruefstand fuer Kompaktlueftungsgeraete fuer Komfortlueftung
Energy Technology Data Exchange (ETDEWEB)
This comprehensive, illustrated report for the Swiss Federal Office of Energy (SFOE) by the University of Applied Sciences in Lucerne, Switzerland takes a look at the testing facility at the university that is used to test compact ventilation systems. These feature heat-recovery and return-air heat-pumps and are used in housing built to low energy-consumption standards such as the Swiss 'Minergie' and 'Minergie-P' standards. The primary goal is a technically comprehensive testing programme for compact ventilation units with heat recovery and heat pumps, which can nevertheless be carried out at reasonable cost. In addition to thermal and flow measurements, acoustic measurements are also carried out. The authors quote that the overall assessment provided can also include service and maintenance, materials used and possible problems with thermal ...
2005-12-15
Premium performance heating oil - Part 2, Field trial results
Energy Technology Data Exchange (ETDEWEB)
Limited field trial results of a heating oil additive package developed to minimize unscheduled maintenance indicate that it achieves its goal of keeping heating oil systems cleaner. The multifunctional additive package was developed to provide improved fuel oxidation stability, improved corrosion protection, and dispersency. This combination of performance benefits was chosen because we believed it would retard the formation of sludge, as well as allow sludge already present to be carried through the system without fouling the fuel system components (dispersency should keep sludge particles small so they pass through the filtering system). Since many unscheduled maintenance calls are linked to fouling of the fuel filtering system, the overall goal of this technology is to reduce these maintenance calls. Photographic evidence shows that the additive package not only reduces the amount of sludge formed, but even removes existing sludge from ...
1996-07-01
Energy Technology Data Exchange (ETDEWEB)
Introduction of geothermal heat pump systems, which depend on temperature differential, is investigated for urban areas, which have large energy demands. Results of the surveys on the current situations of geothermal heat pump (GHP) systems indicate that they have already numbered 300,000 units in USA and totaled more than 50,000 units in Switzerland and Northern European countries, and that they are increasing at an annual rate of higher than 10%. The results also indicate that introduction of these systems are well feasible in Japan, which generally has better topographical conditions than American and European countries, and the GHP system with vertical ground heat exchanger is investigated for its topographical and environmental considerations. These systems could annually abate approximately 52 million tons of CO2 (4.3% decrease), if disseminated to all households. They are ...
1999-03-01
A hydroxide mixture as working fluid for absorption heat pumps
Energy Technology Data Exchange (ETDEWEB)
Basic experimental investigations were carried out with an aqueous solution of a mixture of KOH and NaOH for use as an absorbent in absorption heat pumps. Due to its thermophysical properties this mixture allows temperature lifts from evaporator to absorber of more than 75 K (135 F) in a single-stage absorption chiller. Thermophysical and hydrodynamical properties of the solution were measured. Vapor-liquid-equilibrium data and specific heat capacities were determined for concentrations ranging from 35% up to 75% and temperatures up to 200 C (392 F). From these data the enthalpy of the solution was calculated. Additionally the crystallization temperatures, the density, and the viscosity of the solution were determined. The experimental equipment is described. The data are presented as polynomials and diagrams including experimental accuracy. An apparatus was constructed to measure heat and mass transfer ...
1996-11-01
The use of isotopes in hydrology: Proceedings of a symposium, held in Beirut -Lebanon, December 1970
International Nuclear Information System (INIS)
The papers presented at the symposium had covered three general areas in which isotopes could have been beneficially used. these areas are: -Water use and water use efficiency studies. -Ground water investigations -Water problems in the arab countries. The individual papers had dealt with these subjects: -Hydrological research in the arab countries by use of radioisotopes. -The perspectives of use of radioisotopes in hydrological studies in Syria. -Water use efficiency and sub-soil water studies. -Sea water inclusion in a coast el aquifers in Lebanon. -Irrigation requirements of crops in Lebanon as determined by a Neutron probe with reference to other methods. -The use of the neutron moisture meter and other methods of the determination of the evapotranspiration of maize. -Ground water investigations, dating and nuclear ...
1970-12-01
Integral air-conditioning system for electric cars. Integrales Klimasystem fuer Elektroautomobile
Energy Technology Data Exchange (ETDEWEB)
Increasing environmental awareness and new legislation in Europe and, in particular, America have accelerated the development of marketable electric cars which satisfy customer demands in terms of performance, range capability, safety and comfort. Tomorrow's electric cars will therefore require powerful heating and cooling systems for the passenger compartment which meet the conditions specific to this particular mode of transport and which do not overly affect the range capability of such vehicles. At Behr GmbH suitable system concepts were developed at a very early stage which were based on a high proportion of recirculated air, the use of the A/C unit as a heat pump, and heat recovery. This paper will examine two typical A/C systems which combine good heating and cooling characteristics with the low electric power requirement of only 1,5-2 kW. (orig.).
1992-11-01
Energy Technology Data Exchange (ETDEWEB)
A one-dimensional thermal model is derived to describe the temperature field around a vertical borehole heat exchanger (BHEx) for a geothermal heat pump. The inlet and outlet pipe flows are modeled as one, and an effective heat capacity is added to model the heat storage in the fluid and pipes. Parameter estimation techniques are then used to estimate various parameters associated with the model, including the thermal conductivity of the soil and of the grout which fills the borehole and surrounds the u-tube. The model is validated using test data from an experimental rig containing sand with known thermal conductivity. The estimates of the sand thermal conductivity derived from the model are found to be in good agreement with independent measurements.
1998-11-01
Energy Technology Data Exchange (ETDEWEB)
A one-dimensional thermal model is derived to describe the temperature field around a vertical borehole heat exchanger (BHEX) for a geothermal heat pump. The inlet and outlet pipe flows are modeled as one, and an effective heat capacity is added to model the heat storage in the fluid and pipes. Parameter estimation techniques are then used to estimate various parameters associated with the model, including the thermal conductivity of the soil and the grout that fills the borehole and surrounds the U-tube. The model is validated using test data from an experimental rig containing sand with known thermal conductivity. The estimates of the sand's thermal conductivity derived from the model are found to be in good agreement with independent measurements.
1999-01-01
Off peak geothermal heat pump storage system
Energy Technology Data Exchange (ETDEWEB)
The basic design of a system installed in the Columbus, Ohio Zoo is described. The distribution system is described in detail. The control system is microprocessor controlled, with about 50 monitoring points. Preliminary evaluations have indicated that the system can operate with an overall coefficient of performance in excess of 3.5. 1 figure.
1986-03-01
Geothermal program review 16: Proceedings. A strategic plan for geothermal research
Energy Technology Data Exchange (ETDEWEB)
The proceedings contain 21 papers arranged under the following topical sections: Exploration technology (4 papers); Reservoir technology (5 papers); Energy conversion technology (8 papers); Drilling technology (2 papers); and Direct use and geothermal heat pump technology (2 papers). An additional section contains a report on a workshop on dual-use technologies for hydrothermal and advanced geothermal reservoirs.
1998-12-31
Energy Technology Data Exchange (ETDEWEB)
Geothermal heat pump systems necessitate a comprehensive approach to geology and building facilities in order to be energetically useful and efficient. Cooperation with geothermal experts should be sought at an early projecting stage in order to obtain reliable data. Geothermal data and the technical facilities of the building must be matched for the project to be both effective and efficient. (orig.)
2008-01-15
California and western region geothermal heat pump training center
Energy Technology Data Exchange (ETDEWEB)
The Geothermal Energy Association ({open_quotes}GEA{close_quotes}) will create and manage a Geothermal Heat Pump ({open_quotes}GHP{close_quotes}) Training Center to deliver GHP and HVAC courses throughout California in response to imminent demand driven by national promotion. GEA services include providing management structure, cadre, curricula, promotion and physical equipment. The Center is dedicated to infrastructure strengthening goals of the Geothermal Heat Pump Consortium, Inc. ({open_quotes}GHPC{close_quotes}), the California Energy Commission ({open_quotes}CEC{close_quotes}) and Interagency Geothermal Heat Pump Task Force, and Geothermal Energy Association ({open_quotes}GEA{close_quotes}). Second-half 1996 start-up is co-funded by GHPC, CEC, GEA and three California utilities. Initial support is to five utilities representing 70 percent of California ...
1996-12-31
Thermogalvanic effects on the pitting corrosion of water-cooled heat exchangers
Energy Technology Data Exchange (ETDEWEB)
Thermogalvanic corrosion of St3 steel in a temperature range from 25 to 50{degrees}C with a 3.84{degrees}C/cm gradient was studied in a neutral media flow. It is shown that the thermogalvanic effect on the pitting corrosion of water-cooled heat exchangers is decisive but dual. Depending on the composition of the cooling medium, thermogalvanic corrosion may either enhance (0.5 M NaCl) or inhibit (tap water) pitting corrosion.
1995-05-01
Energy and exergy analysis of a ground source (geothermal) heat pump system
International Nuclear Information System (INIS)
Ground source heat pumps (GSHPs), often referred to as geothermal heat pumps (GHPs), offer an attractive option for heating and cooling residential and commercial buildings owing to their higher energy efficiency compared with conventional systems. GSHPs have been used for four years in the Turkish market, although they have been in use for more years in developed countries. The purpose of this study is to present an energy and exergy analysis of a GSHP system with a 50 m vertical 1.25 in. nominal diameter U-bend ground heat exchanger. This system was applied to a 65 m"2 room in the Solar Energy Institute, Ege University, Izmir, for the first time at the university level in Turkey. The Institute, built in 1986, has a livable floor area of 3000 m"2 and uses passive solar techniques. The heating and cooling loads of the room studied were 3.8 ...
2004-03-01
Variable-speed generation enhances hydro operation
Energy Technology Data Exchange (ETDEWEB)
Two major developments have given impetus to wider adoption of variable-speed turbine/generators in hydroelectric plants, both essentially environmental: (1) the need for stream-bed stability below river dams, and (2) the need to minimize fish damage. Also, the need to stabilize pumped-storage and generating efficiencies to match extreme changes in head levels has been a driving force. Variable-speed operation in hydro applications is relatively new to North America. In other parts of the world, it has been used in pumped-storage plants since 1971. In the US, and increasing potential exists for variable-speed hydro, considering the 30 pumped-storage plants already in operation and several river plants struggling with high head fluctuations--including four at stations operated by the Bonneville Power Administration. Several modifications to hydro-plant hardware and operating procedures are actively being considered at ...
1993-07-01
Water consumption during solid state sodium borohydride hydrolysis
Energy Technology Data Exchange (ETDEWEB)
In this paper nickel acetate catalyzed sodium borohydride cartridges have been prepared and hydrolyzed with water for hydrogen production. Two technological solutions have been tested to increase the overall hydrogen yield, namely a porous water diffuser and a hydrophobic membrane. The first was used to improve water diffusion inside the hydride while the second to confine water inside the cartridge. The generated hydrogen flow showed a very reproducible behavior. Hydrogen promptly evolved just after water was pumped into the cartridge. After some initial peaks, a constant hydrogen flow has been recorded for the whole reaction time. The constant flow was related to the presence of the porous diffuser. The use of a hydrophobic membrane to confine the water inside the cartridge allowed to increase the overall hydrogen yield: about 6 ...
2010-11-15
Engineering masterpieces : from the Andes to Siberia, Canadian talent is in demand
Energy Technology Data Exchange (ETDEWEB)
Canadian oilfields are a prime breeding ground for talent, technology and industrial management. This paper described how Canadian talent was recognized in 2001 for three major projects which included a cold-ocean production platform in the Sea of Okhotsk in Siberia, a mountain pipeline project in South America, and an in-situ underground extraction technology in the oilsands of Alberta. The cold-ocean production platform project was recruited by Sakhalin Energy Investment Co., an international consortium originally led by Marathon Oil Co which is now led by Royal Dutch Shell. The oil production platform is stationed 16 kilometres offshore of Sakhalin Island in the Sea of Okhotsk. Sakhalin Energy bought and converted the Molikpaq, an innovative platform made in the 1980s for the Beaufort Sea by Gulf Canada Resources Ltd. The second project included Calgary's Hydroconsult EN3 Services Ltd. which was responsible for the construction of the 940-km GasAtacama 24-inch diameter ...
2001-03-05
An assessment of the building sector efficiency resource for the Town of Handlova
Energy Technology Data Exchange (ETDEWEB)
Purpose of this assessment for this town in the Slovak Republic is to develop information on the building sector energy efficiency and improvement potential for use by town management to support decisions on providing energy services to Handlova citizens. Objectives were to characterize baseline space and water heat energy use and efficiency improvement potential in the residential and nonresidential building sectors. Intention was to identify major areas of efficiency improvement potential and cost-effectiveness. Four levels of energy and fuel prices were used. A significant efficiency resource exists in the space and water heating end uses in these building sectors; it amounts to 42% of the total building sector space and water heat energy consumption.
1995-10-01
Combined-cycle cogen plant a successful good neighbor
Energy Technology Data Exchange (ETDEWEB)
This article describes a new natural-gas-fired combined cycle cogeneration plant in Bellingham, Washington. The topics of the article include community impact, siting constraints, natural gas fuel, the flexibility provided by the steam turbine, the cooling tower and pumps, air-quality, noise, and cooling water system constraints, and community relations program.
1993-04-01
Two types of evacuated tube solar collectors have been operated in space heating, cooling and domestic hot water heating systems in Colorado State University Solar House I. An experimental collector from Corning Glass Works supplied heat to the system from January 1977 through February 1978, and an experimental collector from Philips Research Laboratory, Aachen, which is currently in use, has been operating since August 1978. A flat absorber plate inside a single-walled glass tube is used in the Corning design, whereas heat is conducted through a single glass wall to an external heat exchanger plate in the Philips collector. In comparison with conventional flat-plate collectors, both types show reduced heat losses and improved efficiency. For space heating and hot water supply in winter, the solar ...
1979-01-01
Safety considerations of active process water system shutdown for TAPP - 3 and 4
International Nuclear Information System (INIS)
Active Process Water (APW) System, provided as unitized closed loop system in Tarapur Atomic Power Project Units-3 and 4, serves to remove heat from various heat exchangers. One of the important loads served by APW system is shutdown cooling heat exchangers and if APW shutdown is taken then reactor cannot be maintained in cold shutdown condition. It is estimated that after 7 days of reactor shutdown, if about 20% of the normal cooling flow to shutdown cooling heat exchangers is provided then along with keeping PHT in cold shutdown state, reactor components, moderator, end shield water, calandria vault water and calandria vault concrete temperature can be maintained within technical specification limits for extended duration. (author)
2005-12-01
PWR horizontal steam generator in USSR
International Nuclear Information System (INIS)
This paper describes the construction of PWR horizontal steam generator in Soviet Union, the water chemistry treatment for secondary side, the design of steam separator, the test of heat transfer characteristics and operation. (author).
1985-01-01
Numerical Simulation of Cirrus Clouds - Fire Case Study and ...
... being pulled out of water, the movement is restricted ... This heating depended on the particle size ... hydrometeor injection into the upper tropopause. ...
1991-08-12
Energy Technology Data Exchange (ETDEWEB)
Conference paper regarding research in freeze-protection methods that could extend market acceptance for passive solar domestic water heating systems in more northern climates if the U.S.
2006-05-01
Utility perspective, programs and prospects in the USA. The National Earth Comfort Program
Energy Technology Data Exchange (ETDEWEB)
An overview is presented of the US heating and space conditioning market, with specific emphasis on the type of fuel used. The author highlights he drive of electric utilities to increase their penetration in the space heating markets, and showed how geothermal heat pumps (GHPs) were recognized by utilities as an electrotechnology for all seasons; beneficial for customers, electric utilities and the environment. Then he focused on the utility driven National Earth Comfort Program (officially Geothermal Heat Pump Technology Demonstration and Market Mobilization Program) is a collaborative effort with the US Department of Energy and other public and private sector organizations. It will be implemented by the Geothermal Heat Pump Consortium, Inc. (GHPC), and is designed for the utility industry`s Climate Challenge under the ...
1995-08-01
Energy Technology Data Exchange (ETDEWEB)
`De Groote Wielen` is going to be a newly built area of the municipality Den Bosch, Netherlands. In the period 1998-2011 circa 6,200 houses and 39,000 m{sup 2} will be built. Under the authority of the municipality Den Bosch CE compared a few energy supply options. Attention is paid to three different forms of energy supply: traditional supply of natural gas and electricity, supply of heat (produced by cogeneration gas engines and collective electrical heat pumps) and electricity, and supply of electricity by means of individual heat pumps for each house. Two levels of the energy performance standard are taken into account: 1.2 and 1.0. Also costs and resulting emissions of those options are compared. Next to a quantitative discussion, also the qualitative consequences of the three concepts are dealt with. The most important quantitative consequence concerns the flexibility of the ...
1996-07-01
Solar distillation as an appropriate technology tool in Haiti
Energy Technology Data Exchange (ETDEWEB)
Source Philippe (on the island of La Govave, near Haiti) is described in terms of climatic, sociological, agricultural and technical background. Because of drought conditions, it became necessary to develop a solar still to provide the town with sufficient fresh water. The still, which has been in operation since 1969, is described in some detail as is the construction process. Brackish and sea water are used to produce more than 1250 liters of fresh water each day. A windmill is used to pump the brackish water from a well to an elevated storage tank; it flows by gravity to solar still basins where it is vaporized, then condensed on a sloping glass surface and collected. Benefits of the solar still to the town's economy and health are discussed. Cost of the project was $17,000. 10 references. (MJJ)
1980-06-01
British Library Electronic Table of Contents (United Kingdom)
Phreatic groundwater pumping is affecting water availability for crops in areas with a shallow water table. This can reduce crop growth and so affect farm income. There is a need for a generic and transparent method to assess the agricultural damage caused by water table drawdown. This paper proposes such a method that consists of 'damage tables' relating agricultural production losses to the groundwater regime for different soil/crop combinations found in Northern Belgium. The damage tables are constructed based on numerous simulations with the agrohydrological model SWAP, in which the bottom boundary conditions are gradually changed to reflect different groundwater regimes. The credibility of the resulting metamodel is assessed in three ways: using (1) field data, (2) an existing local e...
2010-01-01
Subcooled Flow Boiling in a Minichannel
British Library Electronic Table of Contents (United Kingdom)
It has been considered that dry-out occurs easily in boiling heat transfer for a small channel, a mini- or microchannel, because the channel was easily filled with coalescing vapor bubbles. In the present study, the experiments of subcooled flow boiling of water were performed under atmospheric conditions for a horizontal rectangular channel for which the size is 1 mm height and 1 mm width, with a flat heating surface of 10 mm length and 1 mm width placed on the bottom of the channel. The heating surface has a top of copper heating block and is heated by ceramic heaters. In the high heat flux region of nucleate boiling, about 70-80% of the heating surface was covered with a large coalescing bubble and the boiling reached critical heat flux as observed by high-speed video. In the beginning ...
2011-01-01
Glass-heat-pipe evacuated-tube solar collector
A glass heat pipe is adapted for use as a solar energy absorber in an evacuated tube solar collector and for transferring the absorbed solar energy to a working fluid medium or heat sink for storage or practical use. A capillary wick is formed of granular glass particles fused together by heat on the inside surface of the heat pipe with a water glass binder solution to enhance capillary drive distribution of the thermal transfer fluid in the heat pipe throughout the entire inside surface of the evaporator portion of the heat pipe. Selective coatings are used on the heat pipe surface to maximize solar absorption and minimize energy radiation, and the glass wick can alternatively be fabricated with granular particles of black glass or obsidian.
1981-08-06
Heat Transfer Characteristics of Tubular Thermal Reactor
International Nuclear Information System (INIS)
Heat transfer augmentation based on the process intensification concept in heat exchangers and thermal reactors has received much attention in recent years, mainly due to energy efficiency and environmental considerations. The concept consists of the development of novel apparatuses and techniques that, compared to those commonly used today, are expected to bring dramatic improvements in manufacturing and processing, substantially decreasing equipment size, energy consumption, and ultimately resulting in cheaper, sustainable technologies. The objective of this paper was to investigate the heat transfer characteristics of tubular thermal reactor using static mixing technology. Glycerin and water were used as the test fluids and water was used as the heating source. The results for heat transfer rate were strongly influenced by tube geometry ...
Energy Technology Data Exchange (ETDEWEB)
The gross calorific value (H{sub o}) is the amount of heat which is generated by total combustion of a type of fuel. It also includes that part of heat which is generated by steam from evaporated water contained in heating gas. In conventional heating boilers, this heat portion is not being utilized at all. To utilize the gross calorific value, it is necessary to extract from the exhaust gas the evaporation heat bound in steam and to return this to the heating system. This means that the exhaust gas has to be chilled by the return water of the heating system and condensed in suitable heat exchangers to well below the dew point. (orig.) [Deutsch] Waermelieferanten im Bereich der Nahwaermeversorgung koennen durch die Anwendung verfuegbarer und bewaehrter ...
1999-01-01
Energy Technology Data Exchange (ETDEWEB)
The thermal-hydraulic performance in periodic frosting conditions is experimentally studied for the parallel-flow parallel-fin heat exchanger, henceforth referred to as a PF{sup 2} heat exchanger, a new style of heat exchanger that uses louvered bent fins on flat tubes to enhance water drainage when the flat tubes are horizontal. Typically, it takes a few frosting/defrosting cycles to come to repeatable conditions. The criterion for the initiation of defrost and a sufficiently long defrost period are determined for the test PF{sup 2} heat exchanger and test condition. The effects of blower operation on the pressure drop, frost accumulation, water retention, and capacity in time are compared under the conditions of 15 sequential frosting cycles. Pressure drop across the heat exchanger and overall heat transfer coefficient ...
2010-09-15
A desiccant dehumidifier for electric vehicle heating
Energy Technology Data Exchange (ETDEWEB)
Vehicle heating requires a substantial amount of energy. Engines in conventional cars produce enough waste heat to provide comfort heating and defogging/defrosting, even under very extreme conditions. Electric vehicles (EVs), however, generate little waste heat. Using battery energy for heating may consume a substantial fraction of the energy storage capacity, reducing the vehicle range, which is one of the most important parameters in determining EV acceptability. Water vapor generated by the vehicle passengers is in large part responsible for the high heating loads existing in vehicles. In cold climates, the generation of water vapor inside the car may result in water condensation on the windows, diminishing visibility. Two strategies are commonly used to avoid condensation on windows: windows are ...
1996-09-01
Turbulent heat transfer augmentation using microscale disturbances inside the viscous sublayer
Energy Technology Data Exchange (ETDEWEB)
The authors report here on an experimental study of heat transfer augmentation in turbulent flow. Enhancement strategies employed in this investigation are based on the near-wall mixing processes induced in the sublayer through appropriate wall and near-wall streamwise-periodic disturbances. Experiments are performed in a low-turbulence wind-tunnel with a high-aspect-ratio rectangular channel having either (a) two-dimensional periodic microgrooves on the wall, or (b) two-dimensional microcylinders placed in the immediate vicinity of the wall. It is found that microdisturbances placed inside the sublayer induce favorable heat-transport augmentation with respect to the smooth-wall case, in the near-analogous momentum and heat transfer behavior are preserved; a roughly commensurate increase in heat and momentum transport is termed favorable in that it leads to a reduction in the ...
1992-05-01
Hydrodynamics induced vibration to trash-racks
International Nuclear Information System (INIS)
In conventional power plants trash-racks are provided at the intakes to protect the turbines. In pumped storage plants, the draft tube or tailrace must also have trash-racks to protect the units while pumping. Because the loads believed to cause many failures of trash-racks are dynamic in nature, it is important to understand the dynamic characteristics of trash-racks structures in general and a single rack in particular. The classical added-mass solution structure-fluid dynamic interaction is known as an approximate solution procedure. An accurate added-mass approach mixed with implementation in finite element framework is proposed. In this proposal, experimental conclusions, supported by theory, led to presentation of more accurate results in vibration of trash-racks. This numerical solution as a powerful method to solve such a complex problem can be employed to carry out dynamic characteristics of these structures while vibrating in ...
2002-12-01
Energy Technology Data Exchange (ETDEWEB)
This final report for the Swiss Federal Office of Energy looks at the possibilities for improved waste water utilization in the Lavey-les-Bains thermal spa, Switzerland. According to the regulations in force, the temperature of the waste water rejected into the Rhone river shall not exceed 30 {sup o}C, what is currently not the case. Also the operational cost shall be reduced and the waste water quality improved. The installations are presented. From the two geothermal wells, mineral water comes out at an average flow rate of 940 l/min and a temperature of 63 {sup o}C. Actual waste water data are reported. The measured thermal water consumption data, including seasonal variations, are analysed by computerized simulation and measures to reduce the consumed volume by the optimization of internal procedures are evaluated. Measures to reduce the quantity of the ...
2004-07-01
Waste heat utilization in the thermal spa of Lavey-les-Bains
International Nuclear Information System (INIS)
This final report for the Swiss Federal Office of Energy looks at the possibilities for improved waste water utilization in the Lavey-les-Bains thermal spa, Switzerland. According to the regulations in force, the temperature of the waste water rejected into the Rhone river shall not exceed 30 "oC, what is currently not the case. Also the operational cost shall be reduced and the waste water quality improved. The installations are presented. From the two geothermal wells, mineral water comes out at an average flow rate of 940 l/min and a temperature of 63 "oC. Actual waste water data are reported. The measured thermal water consumption data, including seasonal variations, are analysed by computerized simulation and measures to reduce the consumed volume by the optimization of internal procedures are evaluated. Measures to reduce the quantity of the rejected free ...
Energy Technology Data Exchange (ETDEWEB)
This is Volume 3 in a series of documents on energy efficiency of consumer products. This volume discusses energy efficiency of water heaters. Water heaters are defined by NAECA as products that utilize oil, gas, or electricity to heat potable water for use outside the heater upon demand. These are major appliances, which use a large portion (18% on average) of total energy consumed per household (1). They differ from most other appliances in that they are usually installed in obscure locations as part of the plumbing and are ignored until they fail. Residential water heaters are capable of heating water up to 180{degrees}F, although the setpoints are usually set lower.
1993-11-01
GeoExchange market development : the US experience
Energy Technology Data Exchange (ETDEWEB)
In 1994, the United States Department of Energy, the United States electric utilities and the geothermal heat pump (GeoExchange) industry formed a non-profit collaborative effort called the Geothermal Heat Pump Consortium (GHPC). The objectives were the reduction and/or elimination of 1.5 million metric tons of carbon equivalent per year and making geothermal heat pumps a significant part of the Heating Ventilation Air Cooling (HVAC) industry. Federal funding of 35 million dollars over six years was matched by 65 million dollars of private sector funds to attain these objectives and create a self-sustainable GeoExchange market. The major accomplishments of this endeavour, as well as the lessons learned were presented in this paper. The infrastructure was strengthened, first cost was reduced, and awareness of the technology was increased over ...
2000-12-01
International Nuclear Information System (INIS)
A study has been performed of the initial corrosion of support structure alloys in crevices of various geometries, when galvanically coupled to alloy 600. Corrosion rates were monitored continuously by measuring the galvanic current flowing in each couple, transduced by a zero impedance ammeter. Experiments were performed in a single-pass flowing electrolyte system, with AVT water pumped through alloy 600 tubing past the orifice of each crevice. Fourteen crevices were studied simultaneously in two parallel flow arms containing seven specimens each. The steady state AVT water pH/hydrazine/oxygen concentrations were controlled by microcomputer, allowing the effect of secondary water chemistry on the corrosion rate to be studied easily. Control of the crevice electrolyte composition was achieved by separately pumping electrolyte, at a low rate, directly into the crevices of the seven ...
1985-03-01
Energy saving self-powered industrial dehumidifier
Energy Technology Data Exchange (ETDEWEB)
An energy saving self-powered industrial dehumidifier for use in a building having a tap water conduit leading from a source of supply to utilization points is described comprising: a dehumidifying apparatus positioned in a stream of air to be dehumidified in the building. The dehumidifying apparatus comprising conduit means for diverting at least a portion of a relatively continuously moving stream of tap water from the tap water conduit through a heat exchanger positioned in a stream of air and returning the diverted portion to the tap water stream upstream of the utilization points. Water vapor in the stream of air will condense onto the heat exchanger when the tap water has a temperature below a dew point temperature of the air stream, thereby dehumidifying the air stream.
1988-07-26
Simplified solar fraction estimation for space and water heating at DOD installations. Final report
Energy Technology Data Exchange (ETDEWEB)
A set of nomographs is provided which can be used to estimate the average annual solar fraction for solar space and water heating at a large number of DOD facilities. The solar fraction estimated from the nomograph is in close agreement with F-Chart 3.0 and allows for variation of the following parameters: annual load, collector area, collector transmittance-absorption coefficient, and collector overall loss coefficient.
1982-09-01
Screening Criteria for Loss of Room Cooling Failure
Energy Technology Data Exchange (ETDEWEB)
In this report, we estimated the temperature of the pump rooms and reviewed the operability of the components under the loss of the HVAC (Heating, Ventilation, and Air Condition) system. The issues relevant to the HVAC system in the PSA (Probabilistic Safety Assessment) FT (Fault Tree) model are as follows: (1) Does the loss of the HVAC system bring about a function failure of other components? (2) Can the operator take action to reduce the temperature of the room in case of a HVAC function failure? At present, we do not know whether a component will lose its function or not under the loss of the HVAC. ASME Standard describes that a recovery action can be credited if the related recovery action is included in the procedure or there are similar recovery experiences in the plant. However, there is no description about the recovery action of the HVAC in the EOP (Emergency Operation Procedure) of the UCN3, 4 under the situation of a loss of the ...
2007-01-15
International Nuclear Information System (INIS)
The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)
1999-08-22
Energy Technology Data Exchange (ETDEWEB)
The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)
1999-08-01
A metal matrix for heat transfer enhancement during phase-change processes
Energy Technology Data Exchange (ETDEWEB)
A metal matrix is inserted into a phase-change material to enhance the heat transfer during phase-change processes. The metal matrix tends to act like a heat transfer fin from the heated or cooled surface and to increase the effective thermal conductivity of the phase-change fluid. The scope of the study involves numerically modeling the heat transfer to and from constant-temperature cylindrical tubes surrounded by water during the freezing and melting processes. Comparisons of heat transfer with and without the metal matrix are made, with different porosities and densities of the metal matrix being examined. The results of this study are discussed in terms of the effectiveness of the metal matrix as a heat transfer enhancement device.
1994-12-31
Visualization of direct contact heat transfer between water and molten alloy
Energy Technology Data Exchange (ETDEWEB)
We have been developing an innovative Steam Generator concept of Fast Breeder Reactors by using liquid-liquid direct contact heat transfer. In this concept, the SG shell is filled with a molten alloys, which is heated by primary sodium. Water is fed into the high temperature molten alloy, and evaporates by direct contact heating. In order to obtain the fundamental information to discuss the heat transfer mechanisms of the direct contact between the water and the alloy, this phenomenon was visualized by real-time neutron radiography. JRR-3M real-time thermal neutron radiography in Japan Atomic Energy Research Institute was used. Followings are main results. (1) The vigorous evaporation occurs in the molten alloy. This phenomena is different from the known phenomenon such as the evaporation of refrigerant R-113 in the water. (2) The ...
1996-06-01
Energy Technology Data Exchange (ETDEWEB)
The deep borehole heat exchanger (BHE) of Weggis is operational since 1994. During the years 1995 to 2000 the BHE has produced for both, direct heating and as a source for the heat pumps, a yearly amount of heat of 220 MWh. The share of direct heating has been more than 60%. The global average power delivered to all consumers has been about 100 kW. This has yielded to a mean source temperature out of the deep BHE of 40.5 {sup o}C and to a mean return temperature of 33.3 {sup o}C. During the years 2000 and 2001 three additional multi-family dwellings have been connected as heat consumers to the BHE. The amount of delivered heat has nearly been doubled (from 220 to 440 MWh per year) as well as the nominal load. This has induced a small reduction of the delivery temperature and a significant reduction of the return ...
2003-07-01
Mathematical modeling of a direct contact humidification?dehumidification desalination process
British Library Electronic Table of Contents (United Kingdom)
Using air as a carrier gas is common in humidification?dehumidification desalination processes. A computer program was written using mass and energy balances for modeling the process behavior. The parameters considered in this work were inlet air and fresh water recycle temperatures, inlet air flow rate, saline water and fresh water recycle flow rates, and saline water to air flow ratio. Results of simulation showed that increasing inlet air and fresh water recycle flow rate increases fresh water production. It was also found that heating the inlet air to humidification column or cooling the inlet water to dehumidification column increases the production rate but increasing water to air flow ratio in a humidifier leads to a lower production rate. The predicted effects of the parameters on ...
2009-01-01
Some sensitivities during a LWR severe core-damage sequence
International Nuclear Information System (INIS)
Stable boiloff of core water during a severe LWR accident, that is, boiloff driven only by the decay power generated below the water level, is tractable analytically and is relatively insensitive to axial power distribution. As might be expected, calculated accident event times are sensitive to the fidelity of the decay power model. During later stages of boiloff, heat transfer or transport of energy from above the water level to the residual water can result in an unstable condition during which the boiloff rate increases greatly. The unstable boiloff phenomenon illustrates the highly nonlinear influence of core heat transfer during meltdown and emphasizes the great accuracy requirements which attend the modeling of the accident during periods of enhanced heat transfer when significant zirconium oxidation is possible.
1981-12-04
Modeling of snow melting and uniform wetting front migration in a layered subfreezing snowpack
Energy Technology Data Exchange (ETDEWEB)
A method of modeling freeze-thaw cycles of naturally deposited snowpacks is presented. The model involves the Stefan condition as an independent governing equation on the exterior moving boundary to calculate snowpack thinning, flow of water through a variably saturated layered porous medium as described by the Richards equation, and heat conduction with a phase change. The heat conduction problem was treated in two ways. Local heat conduction between a snow grain and its surrounding water film was treated by using a simple energy balance. Global heat conduction with a phase change (the Stefan problem) was introduced to calculate the space-time temperature distribution. In order to handle multiple interior moving boundaries, a specific form of the enthalpy formulation was used for heat conduction with a phase change. Changing material ...
1994-08-01
GRI's Gas Appliance Technology Center Activities at Battelle. Final report, 1986-1992
The Gas Research Institute established the Gas Appliance Technology Center (GATC) in 1982 to develop improved gas appliances. Between 1986 and 1992, the scope of GATC activities at Battelle included technology transfer and overall industry support, residential appliances, commercial appliances, and residential space conditioning. The following tasks are representative of the GATC activities described in the report; gas burner technology, appliance venting, emissions, water heating, range/oven technology, self-powered appliances, commercial cooktop burners, reconstituting ovens, appliance reliability improvement, combination space-heating/water-heating systems, condensing heat exchangers, corrosion testing, and space heating technology. The report includes references to available sources for further reading.
1993-08-01
Toward success of a market mobilization effort: the National Earth Comfort Program
Energy Technology Data Exchange (ETDEWEB)
Work of the Geothermal Heat Pump Consortium (GHPC), a joint program of the US Department of Energy, the US Environmental Protection Agency, the US electric utilities and industry was described. The consortium was established to improve energy efficiency and reduce CO{sub 2} emissions by moving ground source and groundwater source heat pumps from niche products to ten percent of the new and retrofit HVAC market in less than a decade. The GHPC program focuses on : (1) reducing first costs through technology innovation and innovative financing, (2) strengthening the infrastructure though education, training and work codes and regulations, and (3) building confidence in the technology through demonstrations of cost-effectiveness, low maintenance efforts and through marketing programs. Results of the first two years of operations were described. Results indicate that the objectives are being achieved, the ...
1997-11-01
Energy Technology Data Exchange (ETDEWEB)
Combustion characteristics and engine performances of a two-stage injection DI diesel engine were experimentally investigated. Two-stage injection was achieved by using two injection pumps. Injection timing and fuel allocation ratio between first and second injection were widely controlled, Engine performance of a two-stage injection diesel engine was compared with that of a single injection diesel engine with early timing injection. The heat release rate was analyzed to understand the combustion phenomena in a two-stage injection diesel engine. As a result, NO emission of two-stage injection diesel engine was improved when the first injection timing is early. The various pattern of heat release rate appeared with the change of a fuel allocation ratio. It was greatly affected by the first injection spray impinged on the cylinder wall or the piston top. The trade-off tendency between NO and smoke was influenced by the fuel ...
2000-06-25
International Nuclear Information System (INIS)
Heat transfer and flow characteristics of water boiling flow were experimentally investigated in narrow horizontal rectangular channels with the gaps of 0.6mm-2.03mm. The heat transfer of two-phase boiling flow was weakend in smaller gap. The two-phase friction pressure drop decreased with the gap size and the two-phase friction multipliers were smaller compared with those in normal channels. Correlations to predict te boiling heat transfer coefficients were obtained. (author)
2003-05-28
International Nuclear Information System (INIS)
A fluidic pump comprises a two-diode pump having a first displacement vessel, a third diode connected to receive output from the two-diode pump through a delivery line and discharge to an outlet, and a second displacement vessel connected to the delivery line. There is a feed tank at a greater height than the two-diode pump, and a drive unit for alternately pressurising and venting the first and second displacement vessels. The drive pressure required to operate the pump can be of the order of half that for a single stage 2-diode pump. (author).
1988-05-19
Freeze protection valve and system
Energy Technology Data Exchange (ETDEWEB)
The present invention is a device for a solar heating system having a solar collector, a storage tank connected to the solar collector, a pump for circulating liquid from the tank to the solar collector, a supply of liquid at a temperature above freezing and a connection from the supply of liquid to the solar collector for replacing any liquid lost from said solar collector. The device comprises a sensor for sensing the temperature of liquid in the solar collector, and a valve for bleeding liquid from the solar collector when the sensed temperature falls below a predetermined minimum whereby cool liquid in the solar collector is automatically replaced by liquid at a temperature above freezing.
1985-12-10
Engineering study on steam storage power generation. System screening and efficiency
Energy Technology Data Exchange (ETDEWEB)
Large scale steam storage power generation, one of the new energy storage systems for the future of inflexible electric power sources consisting of nuclear and coal power plants has been studied on the subjects of the systems to be attached to coal and nuclear power units, of the definition of storage efficiency and of the vertical steam storage vessel technology. Steam storage power generation may be hopeful for its higher efficiency similarly defined as of pumped storage plants while high temperature heat storage and the internal structure of large vertical steam storage vessel (accumulator) need to be developed.
1981-11-01
Engineering study on steam storage power generation
International Nuclear Information System (INIS)
Large scale steam storage power generation, one of the new energy storage systems for the future of inflexible electric power sources consisting of nuclear and coal power plants has been studied on the subjects of the systems to be attached to coal and nuclear power units, of the definition of storage efficiency and of the vertical steam storage vessel technology. Steam storage power generation may be hopeful for its higher efficiency similarly defined as of pumped storage plants while high temperature heat storage and the internal structure of large vertical steam storage vessel (accumulator) need to be developed. (author).
1981-01-01
Experimental and theoretical studies on humidification-dehumidification-desalination
Energy Technology Data Exchange (ETDEWEB)
The shortage of fresh water is increasing at alarming levels, even in temperate zones. Desalination of brackish and seawater is being considered as a solution to growing water demands. Seawater desalination can be accomplished through reverse osmosis, vapor compression, vapor absorption and thermally driven systems. The most suitable process for large-scale desalination plants is successive brine evaporation-condensation with intermediate heat recovery. However, higher process efficiency could be achieved. The use of low temperature heat sources in seawater desalination requires an efficient method of evaporation and condensation at relatively low vapor pressures. This could be achieved in a humidification-dehumidification process using circulated air to enhance evaporation of water. Simulation models, however, neglect either the heat of evaporation or the ...
2006-07-01
Energy Technology Data Exchange (ETDEWEB)
Drying fine coal by microwaves is now being considered as a viable option by some coal producers. The interest in microwaves is due to problems encountered with current thermal or hot-air drying methods. The technical feasibility of drying minus 5mm coal fines by microwaves was demonstrated using pilot-scale continuous processing system. Results showed that water absorbs microwave energy significantly; but coal does not. Secondly, microwave energy heats only the water, unlike existing drying methods, which heat both water and coal. Finally, the method was found to be energy efficient and minimised the generation of dust.
1989-03-01
Design and performance of the solar-powered floor heating system in a green building
Energy Technology Data Exchange (ETDEWEB)
In the green building of Shanghai Research Institute of Building Science, the evacuated tubular solar collectors with a total area of 150 m{sup 2} were installed to provide heating for the covered area of 460 m{sup 2}. The floor heating coil pipes were made of high-quality pure copper with the dimension of {phi} 12 x 0.7 mm. Under typical weather condition of Shanghai, the average heating capacity was 25.04 kW during the working hours from 9:00 to 17:00, which was sufficient to keep indoor thermal environment. The average electric COP of the floor heating system was 19.76 during the system operation. Compared with the widely used air-source heat pump heating systems with the electric COP of 3.5 in Shanghai, the solar-powered floor heating system shows great potential in energy conservation in winter. With respect to the ...
2009-07-15
The building tomorrow and after..; Le batiment demain et apres-demain..
Energy Technology Data Exchange (ETDEWEB)
During its jubilee, the French building technical and scientific centre (CSTB) has organized a colloquium about the future tendencies of buildings evolution in the 20 forthcoming years: autonomy in energy production and wastes or effluents management, reduction of water consumption and management of water, hot water production and space heating, bio-sensors for the management of indoor air-quality, control of noise environment using active acoustic systems etc.. (J.S.)
1998-01-01
Lamp system for uniform semiconductor wafer heating
Energy Technology Data Exchange (ETDEWEB)
A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.
2001-01-01
Depth of origin of the gas content in thermal waters
Energy Technology Data Exchange (ETDEWEB)
The gas composition of recent thermal waters is in perfect conformity with their geologic-tectonic positions. The composition of gas-liquid inclusions in the basic-hyperbasic xenoliths of basaltoid lavas depends on the depth from which xenoliths are supplied. (The depth is determined by using the methods of geological thermobarometers). By comparing available data the conclusion was drawn that the gas compositions of thermal waters reflect the depth of generation of deep fluid which heats them and depends on the penetration depth of the fluid-conducting fissure zones.
1980-01-01
Multi-Dimensional Analysis for Sodium Hot Pool using MARS-LMR in Steady State
International Nuclear Information System (INIS)
DBEs (Design Basis Event) of KALIMER-600 (Korea Advanced Liquid Metal Reactor) were analyzed in one dimension by KAERI (Korea Atomic Energy Research Institute). KALIMER-600 is the pool type SFR (Sodium cooled Fast Reactor), thereby the sodium of primary system is prohibited movement to out of a reactor vessel. There are many contacting and including compositions in the sodium hot pool, such as IHX (Intermediate Heat eXchanger), DHX (Decay Heat eXchanger), Pump, UIS (Upper Internal Structure), and core. Moreover, the complex phenomena are occurred in sodium hot pool during steady and transient states. Therefore, the one dimensional analysis is modified to the multi-dimensional analysis through modification of sodium hot pool from one to three dimensions
2010-10-01
Hydroelectric power in Switzerland: large growth potential by increasing the installed power
International Nuclear Information System (INIS)
Due to its important hydroelectric power generation facilities (about 525 plants with a total power of 13,314 MW producing about 35.3 TWh annually) Switzerland plays an important role in the interconnected European power system. Large artificial storage lakes in the Swiss Alps can generate peak power during hours of highest demand: 9700 MW are available from accumulated energy and the total power of pumped-storage facilities amounts to 1700 MW. The latter allow refilling the reservoirs at periods of low power demand and generating power at periods of peak demand. In the case of favorable conditions, the yearly average power production could be increased by 6% and the production during the winter period (October to March) by 20% by the year 2020. However, looking forward to the year 2050, the annual production is expected to decrease by 3% despite a possible extension of hydropower. This decrease is due to the enforcement of the minimum residual ...
Studies on water treatment by adsorption. Kyuchaku ni yoru mizushori
Energy Technology Data Exchange (ETDEWEB)
This paper summarizes studies on the water treatment by adsorption, as for the adsorption during water treatment, reactivation of activated charcoal, and clarification of heating process. Reactivation of activated charcoal for the water treatment is carried out through drying in the heating furnace. Basic problems are the recovery degree of adsorption performance of reactivated activated charcoal and the recovery yield. Behavior of the activated charcoal in the heating reactivation furnace is divided into three stages including drying process, heating process, and gasification process. Among these processes, behaviors of organic matters during heating process are described. Thermogravimetric analyses (TGA) were conducted for activated charcoals adsorbing various organic matters in aqueous solutions. Three types of ...
1994-06-05
Energy Technology Data Exchange (ETDEWEB)
The purpose of this solar energy project was to design, manufacture, install, maintain and evaluate solar heating systems in order to stimulate community acceptance of the practicality of solar applications, reduce non-renewable energy resource consumption, and decrease residential expenditures for energy. The project also provided skill training and experience for CETA employees in the design, manufacture, and installation of solar energy equipment systems. CDC's contract had four separate solar energy projects; namely: Domestic Water Heating Systems for four Single-Family Homes; Domestic Water Heating for an industrial building; Domestic Water Heating for a (4) unit apartment complex (includes (12) supplemental space heating units); and Integral Passive Water Heaters and Energy ...
1983-10-19
Thermal energy storage system with stearic acid as phase change material
Energy Technology Data Exchange (ETDEWEB)
A simple tube-in-tube heat exchanger system for thermal energy storage employing stearic acid as PCM has been investigated. The performance and heat transfer characteristics of such a system were studied. Phase transition temperature range and times were measured and the speed of the phase transition front was computed. The melting front was found to move in the radial direction inward as well as in the axial direction from the top toward the bottom of the phase change material PCM tube. The speed of the melting front is enhanced by a convection heat transfer mechanism in the melted PCM. The heat transfer rate and, consequently, phase transition time can be altered by changing the water inlet temperature to the heat exchanger. In addition, a faster phase transition is realized by placing the heat exchanger in a horizontal position rather ...
1994-10-01
International Nuclear Information System (INIS)
The lower condition factors for two catfish species in water heated by effluents from APCo's Glen Lyn, Virginia plant as compared to control areas probably is not due to lack of food as evidenced by macroinvertebrate sampling and the fact that only 4.3 percent of the catfish stomachs were empty. Results suggested that young-of-the-year channel catfish were nonselectively eating food organisms present at both control and heated stations. The difference between stomach contents of flatheat catfish from the heated site and fauna available at that site indicated that fish were either moving out of the heated area to feed or were selectively feeding on organisms (particularly mayflies) which were in the substrate or drifted into the heated area. Stomach contents of the two species and distribution and abundance of the macroinvertebrate benthos community are detailed.
Removal of uranium by biosorption
Energy Technology Data Exchange (ETDEWEB)
The technology developed here will exploit the ability of microorganisms to remove dissolved metals from aqueous solutions. Microbial sorbents for uranium will be immobilized biosorbents will be deployed ex situ within flow-through reactors for the continuous or semicontinuous treatment of recovered wastewaters. The proposed technology will primarily be applied within a pump-and-treat process using immobilized biosorbents for the large-scale, long-term remediation of uranium-laden surface water or groundwater impoundments (environmental restoration). The technology may be equally useful as an ``end-of-pipe`` treatment of process effluents (waste management). Successful operation of this process will achieve immobilization of the targeted waste and accompanying volume reduction.
1993-06-01
International Water Power and Dam Construction Handbook 1993
Energy Technology Data Exchange (ETDEWEB)
In this handbook, technical reports on a number of hydro plants under construction are provided. In addition tables of compiled data are presented on a world-wide basis for the following: turbine and hydro generator contracts; hydropower resource potential and development; pumped storage plants; the major dams and hydro plants; roller compacted concrete dams and concrete faced rockfill dams; small hydropower. An address database of international organizations of relevance to hydropower development, national power authorities and nation committees of the International Commission an Large Dams is included. A final and major section of the handbook is a buyer's guide providing extensive company data and information on products and services. (UK)
1993-01-01
Energy Technology Data Exchange (ETDEWEB)
Operation safety and reliability are major guidelines in the design of city-gate units. Conventional natural gas heaters operate by a indirect mechanism, where liquid water is used to transfer heat by natural convection between the combustion chamber and the natural gas coil. In this work, the concept of vapor chamber is evaluated as an indirect gas heater. In a vapor chamber, liquid water is in contact with the heat source, and vaporizes. The vapor condenses in contact with the heat sink. A reduced scale model was built and tested in order to compare these two heating concepts where the combustion chamber was replaced by electrical cartridge heaters. This engineering model can operate either as a conventional heater or as a vapor chamber. The comparison between the concepts was done by inducing a controlled power to the cartridges and by measuring the resulting ...
2005-07-01
International Nuclear Information System (INIS)
In this paper, we calculated the radioactive concentration distribution of radioactive waste water, the temperature distribution of drained cooling water and the effect of implement from the Daya Bay Nuclear Power Plant on nearby waters range, discussed and analysed some problems of computational results and computation with Alternating Direction Implicit Method (ADI). The contents of the article included: the establishment of two-dimension tidal current equation, radioactive waste water pollutant dispersion equation and cooling water heat convection diffusion equation, the numerical difference calculation model of tidal current field, concentration field as well as temperature field, effect impingement with ADI method, numerical calculation results. The result of research showed that: when the Daya Bay Nuclear Power Plant is on normal operation and after the ...
Dynamics and developing of natural circulation cooling from vertical upflow and downflow conditions
International Nuclear Information System (INIS)
Several research programs have been conducted to evaluate the capability of natural circulation cooling of reactors following a loss of cooling accident. Both experimental and RELAP5 simulation results were obtained for these studies in a facility with vertical heated tube(s) and a unheated bypass channel. The analytical results showed that, under a certain power level, a natural circulation pattern can be developed from both initial upflow and downflow conditions, and maintained for a significant cooling period. This power level, for the discussion of this paper, is defined as the natural circulation cooling (NCC) power limit. Two import factors, namely the pump coastdown rate and the initial flow direction, are examined in this paper. In the benchmark case, as compared to the experimental results, the RELAP5 simulation program accurately predicted the transient phenomena from forced convection through flow reversal, then, into natural ...
1994-04-05
Energy Technology Data Exchange (ETDEWEB)
Energy from biomass is a CO{sub 2} neutral, sustainable form of energy. Anaerobic digestion is an established technology for converting biomass to biogas, which contains around 60% methane, besides CO{sub 2} and various contaminants. Most types of biomass contain material that cannot be digested; in woody biomass, this portion is particularly high. Therefore, conventional anaerobic digestion is not suited for the production of biogas from woody biomass. While wood is already being converted to energy by conventional thermal methods (gasification with subsequent methanation), dung, manure, and sewage sludge represent types of biomass whose energy potential remains largely untapped (present energetic use of manure in Switzerland: 0.4%). Conventional gas phase processes suffer from a low efficiency due to the high water content of the feed (enthalpy of vaporization). An alternative technology is the hydrothermal gasification: the water contained ...
2007-07-01
Shielding options for the ITER conceptual design
Energy Technology Data Exchange (ETDEWEB)
Several shield options were analyzed for the ITER conceptual design to minimize the nuclear responses in the toroidal field (TF) coils. The total nuclear heating in the physics phase and the insulator dose in the technology phase are the most critical parameters in the design process. The first shield option has type 316 stainless steel and water shielding material. Steel and water also serve as structural material and coolant, respectively. The second option is similar to the first except that borated water is used instead of ordinary water. The other two options include a small layer of lead or boron carbide (B{sub 4}C) at the back of the shield. The last three shield options were considered to reduce the nuclear heating in the toroidal field coils relative to the steel/water shield. An optimization process was performed taking into ...
1989-10-01
Enhancement of convective heat transfer by using microencapsulated PCM slurry
Energy Technology Data Exchange (ETDEWEB)
As a method to make use of a high latent heat of a liquid-solid phase change material in a confined convective heat transfer, a phase change material, lauric acid, was encapsulated in a tiny hollow sphere, and mixed with water, forming a slurry of microencapsulated phase-change material (MCPCM slurry). Four different sizes (200, 100, 50, and 25 {mu}m ID) of MCPCMs were tested in this study. Thermal characteristics of the pure lauric acid and lauric acid MCPCMs were tested by a differential scanning calorimeter. Viscosity of the slurries of water and the capsules was measured by a rotating viscometer. The slurries were also tested in a convective-heat-transfer-test apparatus. (author). 11 refs., 5 figs., 1 tab.
1998-11-01
Canadian R&D on oil-fired combustion systems
Energy Technology Data Exchange (ETDEWEB)
This paper describes research and development presently being conducted on oil-fired space and tap water heating systems by the Advanced Combustion Technology Group, CCRL/ERL/CANMET, in Ottawa, Canada. The presentation will focus on R&D activities at CCRL in support of the Canadian Oil Heat Association (COHA) and of the energy policy initiatives of Natural Resources Canada. Progress will be reported on activities to develop suitable oil-fired integrated systems to satisfy the low energy demands of new homes. The utilization of fuzzy logic-based control heating systems including fan coils for a complete range of old and new North American housing will be discussed. Additional activities to be discussed in the presentation will relate to the development of appropriate seasonal efficiency standards for complex integrated space/water heating systems, as well as ...
1996-07-01
Thermal-hydraulic limitations on water-cooled limiters
Energy Technology Data Exchange (ETDEWEB)
An assessment of the cooling requirements for fusion reactor components, such as the first wall and limiter/divertor, was carried out using pressurized water as the coolant. In order to establish the coolant operating conditions, a survey of the literature on departure from nucleate boiling, critical heat flux, asymmetrical heating and heat transfer augmentation techniques was carried out. The experimental data and the empirical correlations indicate that thermal protection for the fusion reactor components based on current design concepts can be provided with an adequate margin of safety without resorting to either high coolant velocities, excessive coolant pressures, or heat transfer augmentation techniques. If, however, the future designs require heat transfer enhancement techniques, experimental verification would be necessary since no data on ...
1984-08-01
Thermal-hydraulic limitations on water-cooled fusion reactor components
Energy Technology Data Exchange (ETDEWEB)
An assessment of the cooling requirements for fusion reactor components, such as the first wall and limiter/divertor, was carried out using pressurized water as the coolant. In order to establish the coolant operating conditions, a survey of the literature on departure from nucleate boiling, critical heat flux, asymmetrical heating and heat transfer augmentation techniques was carried out. The experimental data and the empirical correlations indicate that thermal protection for the fusion reactor components based on conventional design concepts can be provided with an adequate margin of safety without resorting to either high coolant velocities, excessive coolant pressures, or heat transfer augmentation techniques. If, however, the future designs require unconventional shapes or heat transfer enhancement techniques, experimental verification would be necessary ...
1986-01-01
Thermal-hydraulic limitations on water-cooled fusion reactor components
Energy Technology Data Exchange (ETDEWEB)
An assessment of the cooling requirements for fusion reactor components, such as the first wall and limiter/divertor, was carried out using pressurized water as the coolant. In order to establish the coolant operating conditions, a survey of the literature on departure from nucleate boiling, critical heat flux, asymmetrical heating and heat transfer augmentation techniques was carried out. The experimental data and the empirical correlations indicate that thermal protection for the fusion reactor components based on conventional design concepts can be provided with an adequate margin of safety without resorting to either high coolant velocities, excessive coolant pressures, or heat transfer augmentation techniques. If, however, the future designs require unconventional shapes or heat transfer enhancement techniques, experimental verification would be necessary ...
1987-01-01
Thermal-hydraulic limitations on water-cooled fusion reactor components
International Nuclear Information System (INIS)
An assessment of the cooling requirements for fusion reactor components, such as the first wall and limiter/divertor, was carried out using pressurized water as the coolant. In order to establish the coolant operating conditions, a survey of the literature on departure from nucleate boiling, critical heat flux, asymmetrical heating and heat transfer augmentation techniques was carried out. The experimental data and the empirical correlations indicate that thermal protection for the fusion reactor components based on conventional design concepts can be provided with an adequate margin of safety without resorting to either high coolant velocities, excessive coolant pressures, or heat transfer augmentation techniques. If, however, the future designs require unconventional shapes or heat transfer enhancement techniques, experimental verification would be necessary ...
1986-12-07
Transverse Pumping with Diode Lasers
... Title : Transverse Pumping with Diode Lasers. Descriptive Note : Technical rept. ... Subject Categories : LASERS AND MASERS. ...
1989-01-06
Hydroelectric Power Plants Electrical Design
... Treatment of electrical systems for pumped storage plants is not covered in the manual, although much of the information is applicable to pumped ...
1994-06-30
International Nuclear Information System (INIS)
On all steam turbines operating with condensation the air leakage penetrating from the part of the plant which is under vacuum must be eliminated, in order to maintain the vacuum created by physical conditions. In order to attain effective air bleed-off, the water-steam-air mixture is conveyed via the super-cooling bundles in the condenser. In this way the steam partial pressure decreases and the air partial pressure increases at a constant condenser pressure. In this procedure the mixture is supercooled by about 4"0C compared with the saturate steam temperature appertaining to the condenser pressure. The values of volume of air leakage are the result of a year's experience on existing plant. (orig.).
Final ROI Report - Technology Transfer of Waste-Reducing Groundwater Sampling Systems
Energy Technology Data Exchange (ETDEWEB)
This report presents the findings of a U.S. DOE Environmental Management technology transfer initiative of waste-reducing ground water sampling systems between Savannah River Site (SRS) and Lawrence Livermore National Laboratory (LLNL) which occurred during fiscal years 2001 and 2002. The report describes the collaboration between the two sites, the deployment of the Savannah River Site Purge Water Management System at LLNL, the changes made to that system for use at LLNL, and documents the return-on-investment derived from the system's use at LLNL as well as other benefits generated through this inter-laboratory collaboration. An evaluation of the deployment of the LLNL EasyPump sampling technology at SRS will be covered in a separate report from SRS.
2002-09-30
International Nuclear Information System (INIS)
The loss of seal of the H9 channel in vacuum, freeing the entire cross section of the front part, leads to a fast leak that progresses rapidly. The effect of depressurizing the reflector can leads to shutdown of the shutdown rod pumps. The source changer associated with the channel fills completely before the valve closes. All of the leak water remains contained within the source changer containment. After the valves open, cooling of the fuel element is handled by natural convection, requiring a reversal of the flow between the plates. This changeover, which takes place at a relatively low pressure level, could lead to local boiling in the fuel element. Consequently, irreversible transformations cannot be excluded as possibilities for the fuel element and even for the control rod. Subsequently, the can is refilled with heavy water with establishment of the usual pressure levels.
Construction progress of the cooling & ventilation in the LHC project
After the LEP dismantling Phase the Cooling and Ventilation Group has started the LHC construction work. Year 2001 through to 2004 will certainly be the most important period of activity for the CV group in the erection phase The author will report on the current works that are in progress on the different LHC Points distinguishing between the Ventilation and the Water Cooling installations. The Ventilation work completed in the new surface buildings in Points 1, 4,5,6 and 8. The work for the Cooling plants comprehend to the pumping stations, the cooling towers and the chilled water production stations in Points 1 and 5, For all of these activities, an updated report of the progress the work, the planning and of the expenses are given. Finally, a brief overview of the future activities is presented.
2002-01-01
Construction Progress of the Cooling and Ventilation in the LHC Project
The Cooling and Ventilation Group has started the LHC construction work in September 1999 and will get into full activity when LEP will be stopped and dismantled: in total 12 major contracts for an amount of about 120 MCHF will be established to build the needed installations for the LHC. The author will report on the current works that are in progress on the different LEP Points distinguishing between the Ventilation and the Water Cooling installations. The Ventilation work, completed in the new surface buildings in Points 18, is currently held in Points 4 and 5. Point 1 will follow in the near future. The work for the Cooling plants comprehend the pumping stations, the cooling towers and the chilled water production stations in Points 1 and 5, the buried pipes in Points 1 and 4. For all of these activities, an updated report of the progress of the work, of the planning and of the expenses is given. Finally, a short ...
2001-01-01
Session 1: Geothermal Pumping Systems and Two-Phase Flow Studies
Energy Technology Data Exchange (ETDEWEB)
Improvements in electric submersible pumping systems have resulted in a demonstrated downhole running life of one year for low horsepower units operating in 180 C brine. The implementation of a prototype pressurized lubrication system to prevent brine intrusion and loss of lubricating oil from the motor and protector sections has been successfully tested. Second generation pressurized lubrication systems have been designed and fabricated and will be utilized in downhole production pumping tests during FY84. Pumping system lifetime is currently limited by available power cable designs that are degraded by high-temperature brine. A prototype metal-sheathed power cable has been designed and fabricated and is currently undergoing destructive and nondestructive laboratory testing. This cable design has the potential for eliminating brine intrusion into the power delivery system through the use of a hermatically sealed cable from ...
1983-12-01
Development of the hydropower sector in Japan
Energy Technology Data Exchange (ETDEWEB)
Japan's first water power station to provide public power was the Keage plant (maximum output 160 kW) which began operation in 1891. The installed capacity of pure hydro plants reached 20 481 MW in March 1991; pumped-storage powerplants account for 17 004 MW, making a total of 37 483 MW. Pumped-storage thus represents 45 per cent of total hydro capacity. Pure hydro plants under construction at the end of March 1990 totalled 75, representing 968 MW of capacity. There were also seven pumped-storage plants under construction (each more than 300 MW). The latest survey to establish the hydro potential of Japan indicated the gross theoretical hydro potential to be 717 600 GWh/year and the exploitable potential to be 130 524 GWh/year. Of this exploitable potential, 60 per cent is in operation and 3 per cent is under construction. The exploitable potential represents 4551 pure hydro plants, with a ...
1991-11-01
Oil cable pumping plant. Pumpestasjon
Energy Technology Data Exchange (ETDEWEB)
The invention deals with a pumping plant for oil filled power cables. An air driven piston type pump is used as primary pump. A PLS (Programmable Logic control System) is used to control the oil flow to the cable(s). Improvements of the pump includes means for ensuring that the pump piston is operated also at low pressure and flow, and means for sealing off the piston rod to ensure maximum life of seals, to facilitate detection of possible leakages and to avoid contamination of the cable oil. 3 figs.
1988-12-27
British Library Electronic Table of Contents (United Kingdom)
The objective of this study is to develop an artificial neural network (ANN) model to predict the thermal conductivity of ethylene glycol-water solutions based on experimentally measured variables. The thermal conductivity of solutions at different concentrations and various temperatures was measured using the cylindrical cell method that physical properties of the solution are being determined fills the annular space between two concentric cylinders. During the experiment, heat flows in the radial direction outwards through the test liquid filled in the annual gap to cooling water. In the steady state, conduction inside the cell was described by the Fourier equation in cylindrical coordinates, with boundary conditions corresponding to heat transfer between the solution and cooling water. ...
2009-01-01
Low temperature humidification dehumidification desalination process
Energy Technology Data Exchange (ETDEWEB)
The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling water. The ...
2006-03-01
Low temperature humidification dehumidification desalination process
International Nuclear Information System (INIS)
The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling water. The ...
2006-03-01
Enhancement of Heat and Mass Transfer in Mechanically Contstrained Ultra Thin Films
Energy Technology Data Exchange (ETDEWEB)
Oregon State University (OSU) and the Pacific Northwest National Laboratory (PNNL) were funded by the U.S. Department of Energy to conduct research focused on resolving the key technical issues that limited the deployment of efficient and extremely compact microtechnology based heat actuated absorption heat pumps and gas absorbers. Success in demonstrating these technologies will reduce the main barriers to the deployment of a technology that can significantly reduce energy consumption in the building, automotive and industrial sectors while providing a technology that can improve our ability to sequester CO{sub 2}. The proposed research cost $939,477. $539,477 of the proposed amount funded research conducted at OSU while the balance ($400,000) was used at PNNL. The project lasted 42 months and started in April 2001. Recent developments at the Pacific Northwest National Laboratory and Oregon State University suggest that ...
2005-01-01
Energy Technology Data Exchange (ETDEWEB)
The performance of binary geothermal power plants can be improved through the proper choice of a working fluid, and optimization of component designs and operating conditions. This paper reviews the investigations at the Idaho National Engineering Laboratory (INEL) which are examining binary cycle performance improvements: for moderate temperature (350 to 400 F) resources with emphasis on how the improvements may be integrated into design of binary cycles. These investigations are examining performance improvements resulting from the supercritical vaporization of mixed hydrocarbon working fluids and achieving countercurrent integral condensation with these fluids, as well as the modification of the turbine inlet state points to achieve supersaturated turbine vapor expansions. For resources where the brine outlet temperature is restricted, the use of turbine exhaust recuperators is examined. The baseline plant used to determine improvements in plant performance (characterized by the ...
1989-03-21
The melting unit, consisting of a water-cooled cupola furnace, afterburner, heat exchanger, air preheater, consumes most of the supplied energy in the rockwool process. The report maps the energy flows and defines factors of merit according to thermodynam...
1979-01-01
Solar desalination using humidification dehumidification processes. Pt. 1. A numerical investigation
Energy Technology Data Exchange (ETDEWEB)
A numerical investigation of a humidification dehumidification desalination (HDD) process using solar energy is presented. The HDD system consists mainly of a concentrating solar water heating collector, flat plate solar air heating collector, humidifying tower and dehumidifying exchanger. Two separate circulating loops constitute the HDD system, the first for heating the feed water and the second for heating air. A mathematical model is developed, simulating the HDD system, to study the influence of the different system configurations, weather and operating conditions on the system productivity. The model validity is examined by comparing the theoretical and experimental results of the same authors. It is found that the results of the developed mathematical model are in good agreement with the experimental results and other published works. The results show ...
2004-05-01
Energy Technology Data Exchange (ETDEWEB)
A numerical investigation of a humidification dehumidification desalination (HDD) process using solar energy is presented. The HDD system consists mainly of a concentrating solar water heating collector, flat plate solar air heating collector, humidifying tower and dehumidifying exchanger. Two separate circulating loops constitute the HDD system, the first for heating the feed water and the second for heating air. A mathematical model is developed, simulating the HDD system, to study the influence of the different system configurations, weather and operating conditions on the system productivity. The model validity is examined by comparing the theoretical and experimental results of the same authors. It is found that the results of the developed mathematical model are in good agreement with the experimental results and other published works. The results show ...
2004-05-01
UK PubMed Central (United Kingdom)
Salmonella enterica serovar Typhimurium and enterohemorrhagic Escherichia coli were stressed by prolonged incubation in water microcosms until it was no longer possible...Full Text Available
2002-10-01
UK PubMed Central (United Kingdom)
The resistance to destruction of spores of Bacillus subtilis var. niger occluded in crystals of calcium carbonate and exposed to ethylene oxide and moist and dry heat...Full Text Available
1967-07-01
Energy Technology Data Exchange (ETDEWEB)
;Contents: Energy Use; Building Fabric Performance; Ventilation and Infiltration; Passive Solar Design; Heating Systems and Controls; Hot and Cold Water Provision; and Lighting and Electrical Appliances.
1993-01-01
Contents: Energy Use; Building Fabric Performance; Ventilation and Infiltration; Passive Solar Design; Heating Systems and Controls; Hot and Cold Water Provision; and Lighting and Electrical Appliances.
1993-01-01
The long operating cycle simplified boiling water reactor is a reactor concept that pursues both safety and the economy by employing a natural circulation reactor core without a refueling, a passive decay heat removal, and an integrated building for the reactor and turbine. Throughout the entire spectrum of the design basis accident, the reactor core is kept covered by the passive emergency core cooling system. The decay heat is removed by the conventional active low-pressure residual heat removal system. As for a postulated severe accident, the suppression pool water floods the lower part of the reactor pressure vessel (RPV) in the case when core damage occurs, and the in-vessel retention that keeps the melt inside the RPV is achieved by supplying the coolant. The containment adopts a parallel-double-steel-plate structure similar to a hull structure, which contains coolant between ...
2003-07-15
International Nuclear Information System (INIS)
The RESF is utilized for storage of spent fuel under emergency conditions as well as for testing of FM heads. It receives cooling supply from the PHT Pressurizing pumps and after removal of decay heat from the spent fuel it goes to the D2O Storage Tank. The geometry of the RESF system is such that it can not sustain the thermosyphon loop during SBO, due to high frictional forces. To achieve the sustained thermosyphon, modifications in the design were suggested viz., removal of the steam trap and the relief valve above it and replacement by a solenoid valve (SV-16). In the event of SBO, SV-16 will open on 'RESF channel temperature high' signal and connect to FT D2O tank. The tank, being at atmospheric pressure and at lower elevation, will provide higher cooling flow rate through the RESF channel. D2O is periodically removed from the FT D2O tank by operating a Class-II pump intermittently. The analysis was done for the ...
2006-11-13
Sensitivity Study for CFD Analysis on Debris Transport to ECCS Sump for CANDU Type Plant in Korea
International Nuclear Information System (INIS)
Once containment recirculation pumps are activated and emergency core cooling (ECC) flow is supplied from the recirculation sump during loss of coolant accident (LOCA), various insulations and coatings on a pipe, equipments and structures damaged by LOCA break jet as well as additional debris sources are transported to recirculation sump screen by the break flow and containment spray flow drainage. This debris may result in loss of net pressure suction head (NPSH) of the recirculation pumps, and have a threat to long term cooling and containment heat removal capacity. In this case, flow patterns of containment pool are important to confirm behaviors of debris transport for predicting various flow paths to the recirculation sump screen. In this paper, models using commercial computational fluid dynamics (CFD) software CFX are developed for containment pool simulation during recirculation mode. The specific plant used for ...
2010-10-01
Four loss-of-flow accidents in the SEAFP first wall/blanket cooling system
Energy Technology Data Exchange (ETDEWEB)
This report presents the thermal-hydraulic analysis of four Loss-of-Flow Accidents (LOFAs) in the first wall/blanket cooling system of the alternative SEAFP reactor design. The LOFAs considered result from a loss of electrical power for the recirculation pump in the primary cooling circuit. The analyses have been performed using the thermal-hydraulic system analysis code RELAP5/MOD3. In the analyses, special attention has been paid to the transient thermal-hydraulic behaviour of the cooling system and the temperature development in the first wall and blanket. For the LOFA without plasma shutdown, significant loss of heat removal due to dryout occurs at the midplane of the outboard first wall cooling pipes about 41 s after pump trip. For the three LOFA cases with emergency plasma shutdown that have been studied, the temperature increase in the Be-coating at the midplane of the outboard first wall is limited to about 30 K. ...
1994-07-01
Evaluation of structural integrity of crossover leg piping system with dynamic whip restraints
Energy Technology Data Exchange (ETDEWEB)
Interference between the crossover leg of the Reactor Coolant System(RCS) and the Pipe Whip Restraints(PWR) has brought a degradation issue of the integrity of the Reactor Coolant System in Westinghouse type Nuclear Power Plants(NPPs) of Korea. According to the gap inspection carried out during planned overhaul (year 2000), interference between the crossover leg and the PWR was found in each RCS loop. This plant has had the high vibration problem on the RC pump 'B'. The reason for the high vibration in the RC pump 'B' had been massively surveyed and it was found that the crossover leg of RCS contacted with the PWR in hot condition. Since the contact between the crossover leg and the PWR changes the dynamic characteristics of the piping system for the RCS, this is considered as one reason for the high vibration. And a possibility of overstress on the crossover leg due to the contact with the PWR should be ...
2001-07-01
Post-CHF heat transfer with water and refrigerants
Energy Technology Data Exchange (ETDEWEB)
Heat transfer experiments were performed in the post-CHF two-phase flow regime in a vertical tube. The tube inside diameter was 7.75 mm, and the boiling fluid was R-113. The experiments were performed at steady state by means of liquid heating of the test tube. Wall superheats were maintained below 70 C for heat exchanger/steam generator application. The mass flux range of the data was 379-816 kg m{sup -2} s{sup -1}. The use of R-113 significantly extended the property range of the existing low wall-superheat data base. Experimental data are presented in tabular as well as graphical form, and the results were used with low wall-superheat data from other fluids to add generality to a predictive heat transfer correlation. (orig.)
1996-06-01
British Library Electronic Table of Contents (United Kingdom)
In this paper we review and classify the various patterns of isosteric heat versus loading for adsorption of gases on graphitised thermal carbon black at temperatures ranging from below the 3D triple point to temperatures above it, but less than the 3D critical point. We have identified the features of heat curve and highlighted the microscopic origin of these features. The patterns vary with temperature and with the relative strength of the fluid-fluid interaction and solid-fluid interaction. For simple adsorptives (by simple we meant there is no strong association between fluid particles), the heat curve is typified by fluid-fluid attraction and layering phenomena. For adsorptives showing strong association such as water, ammonia and methanol, the heat curve essentially begins below the ...
2008-01-01
Materials selection for the US INTOR divertor collector plate
Energy Technology Data Exchange (ETDEWEB)
The divertor collector plate in the INTOR reactor will be subjected to high heat, particle, and neutron fluxes, making it the most severely damaged torus component. The collector plate is composed of a protection plate, which is directly exposed to the particle flux, and a heat sink which provides support for the protection plate and carries the water coolant. The high-Z refractory metals have been considered for use as the protection plate material, and austenitic stainless steels and copper alloys have been considered as the heat sink material. Tungsten and Type 316 stainless steels have been selected for the protection plate and heat sink, respectively. The protection plate has a sputtering lifetime of 1.75 y at a 50% duty factor, while the heat sink is expected to last the lifetime of the reactor.
1981-01-01
Energy Technology Data Exchange (ETDEWEB)
Sigma 1) examines ways to reduce the number of breakdowns of pressure-regulating stations and to minimize the energy consumed in warming the gas, 2) determines the optimal gas temperatures upstream from the pressure reduction, and 3) shows the dependence of energy consumption upon the water dewpoint. The method of calculating the optimal input temperature relies on Mollier's diagram. Tables and nomographs for natural gas and water dewpoint at 19/sup 0/F and 580 psi (-7/sup 0/C and 4 MPa) are useful in achieving the desired gas temperatures. Heating the regulators' control valves is important.
1982-04-01
Management and optimization of the CPCU network working
Energy Technology Data Exchange (ETDEWEB)
The CPCU steam distribution network is supplemented by a return network for the condensation water. The data system installed in 1988 provides, for the real time, management of the function of the two networks and a reduction in production costs. For the steam, data required in the network, the boiler houses and from external sources are processed by local network of five microprocessors and permit: - with time delay: technical and economic production optimizing calculations, or forecasts, for the following day, of the total required output and the procedure necessary for supplying this at the lowest cost; - in real time: on the basis of the forecasts for the previous day, creating the production instructions for the boiler houses and the instructions for the network remote control elements; - in case of an unexpected occurrence: immediate creation of new operating forecasts for the boiler houses for the establishing management data in real time. For the ...
1991-10-01
Generalized simulation model for reservoir system analysis. Technical paper
Energy Technology Data Exchange (ETDEWEB)
This paper overviews the general features of computer program 'HEC-5, Simulation of Flood Control and Conservation Systems', with emphasis on the capabilities of the most recent release of HEC-5, Version 7.2, dated March 1991. HEC-5 can simulate the essential features and operation goals and constraints of simple or complex systems with simulation intervals ranging from minutes to one month. Single event flood analysis and period of record conservation analysis may be accomplished with the model. Flood control analysis includes balanced system operation for downstream damage centers with consideration of forecasted local flows and hydrologic routing. In addition, induced surcharge operation based on spillway gate regulation schedules can be simulated. Hydropower analysis may include run-of-river, peaking, and pumped storage plants as well as system power operation. Water supply simulation can include reservoir and downstream ...
1992-03-01
Emergency reactor core cooling device
International Nuclear Information System (INIS)
The device of the present invention improves reactor safety by suppressing lowering of water level in a shroud which surrounds a reactor core, even upon occurrence of rupture of pipelines in an emergency reactor core cooling system in a recycling pump-incorporated type reactor. Namely, an opening of each of cooling systems which forms the emergency reactor core cooling device in a reactor pressure vessel is disposed above the upper end of the reactor core. Further, it also comprises an independent high pressure water injection system, gravitational dropping type water injection system and an automatic depressurization system. With such a constitution, even if rupture of pipelines in the system should be assumed, coolants never flow directly from the shroud which surrounds the reactor core. In addition, there are no pipelines to be ruptured below the upper end of the reactor core with respect to the ...
1993-03-16
Energy Technology Data Exchange (ETDEWEB)
A method and an instrument for determining the total water content in a hydrocarbon fuel using an indicator composition, which includes calcium hydride and phenolphthaleyn, are developed. The essence of the method is fixing the presence of water with its interaction with the calcium hydride and subsequent indication of the formed Ca(OH)2 using the phenolphthallen. To make the indicator composition, a hygroscopic cotton, prewashed by rectified alcohol and dried for 30 minutes at 105 degrees, is impregnated by a 1 percent alcohol solution of phenolphthaleyn and is dried in the same conditions. Then the cotton is processed by a powder form calcium hydride (a layer thickness of 0.1 to 0.2 millimeters, and a granule size of less than or equal to 80 micromters). The indicator composition is placed in a glass tube (a diameter of 4 to 7 millimeters and a length of 80 to 100 millimeters), whose ends are sealed or filled with paraffin. The content of ...
1983-01-01
Thermal energy storage system using stearic acid as a phase change material
Energy Technology Data Exchange (ETDEWEB)
The thermal performance and phase change stability of stearic acid as a latent heat energy storage material has been studied experimentally. The thermal performance and heat transfer characteristics of the stearic acid were tested and compared with other studies given in the literature. In the present study, parameters such as transition times, temperature range and propagation of the solid-liquid interface as well as the effect of heat flow rate on the phase change stability of stearic acid as a phase change material (PCM) were studied. The experimental results showed that the melting stability of the PCM is better in the radial direction than in the axial direction. The variation in the melting and solidification parameters of the PCM with the change of inlet water temperature is also studied. We observed that while the heat exchanger tube is in the horizontal position, the PCM ...
2001-07-01
International Nuclear Information System (INIS)
Heat transfer tubes of a primary pressurized water cooled (PPWC) in the high temperature engineering test reactor (HTTR) form the reactor pressure boundary of the primary coolant, therefore are important from the viewpoint of safety. To establish inspection techniques for the heat transfer tubes of the PPWC, an automatic inspection system was developed. The system employs a bobbin coil probe, a rotating probe for eddy current testing (ECT) and a rotating probe for ultrasonic testing (UT). Nondestructive test of a half of the heat transfer tubes of the PPWC was carried out by the automatic inspection system during reactor shutdown period of the HTTR (about 55% in the maximum reactor power in this paper). The nondestructive test results showed that the maximum signal-to-noise ratio was 1.8 in ECT. Pattern and phase of Lissajous wave, which were obtained for the heat transfer tube of ...
Kootenai River Nutrient Dosing System and N-P Consumption: Year 2008.
In early 2006 we designed and built low energy consumption, pump-operated system, for dosing of the liquid nutrient in the summer 2006 season. This operated successfully, and the system was used again during the 2007 and 2008 seasons for dosing. During the early winter period, 2008, laboratory tests were made of the liquid nutrient pump system, and it was noted that small amounts of air were being entrained on the suction side of the pump, during conditions when the inlet pressure was low. It was believed that this was the cause of diurnal fluctuations in the flow supplied, characteristic of the 2007 year flow data. Replacement of '0' rings on the inlet side of the pumps was the solution to this problem, and when tested in the field during the summer season, the flow supplied was found to be stable. A decision was made by the IKERT committee at the meeting of 20th to 21st May 2008 ...
2009-02-19
On the feedwater heating in a steam generator of horizontal type
International Nuclear Information System (INIS)
Design layout of horizontal steam generator (SJ) with a special feedwater heating surface (by a surface water economizer), designated for NPPs with WWER-1000 reactors, is suggested. The design enables to decrease sharply the difference between the temperatures of saturation and feedwater. Blowdown outlet is organized against PG face, which increases the efficiency of flowing. The suggested layout enables to decrease thermal stresses in structural units and PG metal content, as compared to the PGV-1000 steam generator.
1989-01-01
... The products can be categorised as glazed flat-plate collectors, evacuated glass-tube collectors, and unglazed plastic or low temperature collectors. Glazed flat-plate collectors and vacuum tubes are widely used for solar water heating and space heating systems in all types of buildings. Unglazed plastic collectors are used exclusively for lower temperature applications, such as outdoor swimming pools or the agrarian business. Flat-plate solar collectors are likely to ...
A method of producing a stabilizer of wash drilling muds
Energy Technology Data Exchange (ETDEWEB)
A method is proposed for producing a stabilizer of wash drilling muds; by hydrolysis of polyacrylonitrile in an aqueous solution of alkaline agent with heating. To raise the heat resistance of the stabilizer, as the alkaline agent is used monosilicate of sodium, while the hydrolysis is done at a molar ratio of polyacrylonitrile, sodium monosilicate and water equal to 1.0:0.7-2.5:100, to a degree of hydrolysis of 25-40.
1981-01-01
Energy Technology Data Exchange (ETDEWEB)
Beside sucker-rod-type pumps and submersible centrifugal pumps, excentric screw pumps (so-called progressing cavity pumps) belong to standard conveyors in the production of crude oil. The authors of the contribution under consideration present the further development of excentric screw pumps with respect to the reduction of fluid levels in gas wells. This further development is based on a co-operation between the operator (Rohoel Aufsuchungs AG (Gampern, Austria)), the pump supplier (NETZSCH Oilfield Products GmbH (Selb, Federal Republic of Germany)) and the Institute for Process Technologies and Machinery at the University of Erlangen-Nuernberg (Federal Republic of Germany). The authors report on first attempts with the excentric screw pump at Weizberg (Federal Republic of Germany), material investigations at the University of ...
2008-10-23
Energy Technology Data Exchange (ETDEWEB)
This paper describes the design, operation, and performance of an HVAC system installed as part of a project to demonstrate energy efficiency and environmental responsibility in commercial buildings. The systems installed in the 2180 m{sup 2} office building provide superior air quality and thermal comfort while requiring only half the electrical energy of conventional systems primarily because of the hydronic heating and cooling system. Gas use for the building is higher than expected because of longer operating hours and poor performance of the boiler/absorption chiller.
1998-12-31
Mixed convection flow in a horizontal rectangular channel subjected to a horizontal thermal gradient
British Library Electronic Table of Contents (United Kingdom)
This paper deals with a mixed convection water flow in a horizontal rectangular duct, uniformly heated from one lateral vertical wall and thermally insulated elsewhere. The supplied heat flux induces a secondary flow, which structure is constituted of one longitudinal roll in the considered aspect ratio (??=?1.9), embedded into a return flow of possibly large stream wise extension (up to twenty channel heights). Such situation induces helicoidal trajectories for the fluid flow particles, which contributes to a heat transfer enhancement compared to purely forced convection flow.
2011-01-01
Mixed convection flow in a horizontal rectangular channel subjected to a horizontal thermal gradient
This paper deals with a mixed convection water flow in a horizontal rectangular duct, uniformly heated from one lateral vertical wall and thermally insulated elsewhere. The supplied heat flux induces a secondary flow, which structure is constituted of one longitudinal roll in the considered aspect ratio (? = 1.9), embedded into a return flow of possibly large stream wise extension (up to twenty channel heights). Such situation induces helicoidal trajectories for the fluid flow particles, which contributes to a heat transfer enhancement compared to purely forced convection flow.
2011-04-01
Application of the porous media model for the LWR process components
Energy Technology Data Exchange (ETDEWEB)
Full text of publication follows: A porous media solution PORFLO has been developed for the 3-dimensional two-phase flow by describing the process facility in Cartesian or cylindrical coordinates. The local porosity fraction is applied for distinguishing the fluid filled volumes from the solid structures. The solid structure contribute the two-phase flow through the wall friction, flow area and heat transfer. Optionally the solid structure may contain primary liquid of steam generators, steam in the higher temperature and pressure to be condensed or electrical heating power. By using these optional boundary conditions three different process facilities have been analysed. The thermohydraulic solution based on 5-equation approach, where the conservation equations are solved for the liquid and gas (vapour) mass, mixture momentum (giving the velocity only for the mixture), liquid and gas energy, is described shortly. In addition to that the ...
2005-07-01
A study on convective heat transfer with microcapsulated lauric acid slurry in circular pipe
Energy Technology Data Exchange (ETDEWEB)
The objective of the present study is to reveal thermal characteristic of microcapsulated lauric acid slurry in circular pipe. Test were performed with microcapsulated lauric acid slurry in a heating test section with a constant heat flux boundary condition. Local Nusselt number and the effective thermal capacity were measured. As the size of microcapsulated lauric acid were increased, local Nusselt number of microcapsulated lauric acid slurry were increased. The effective thermal capacity of microcapsulated lauric acid slurry was 0.5 times than it of water.
2003-07-01
Phytoplankton primary production in a eutrophic cooling water pond
Energy Technology Data Exchange (ETDEWEB)
The effect of longer ice-free periods on the seasonal variation and total annual values of phytoplankton primary production was considered along with the efficiency and productivity of the phytoplankton communities at different water temperatures by constant light. The studied pond, Vasikkalampi, is located in the town Jvyaskyla in central Finland. The pond is slightly eutrophic and its water is used for cooling purposes by a 35 MW thermal powerplant. The cooling water is taken in the middle of the pond and it returns as heated effluent to the northern part, near the surface, about 100 m from the intake pipe. This circulation and warming of the water keeps the pond open throughout the year except during the coldest weeks in the winter when some parts freeze over. The increase of the water temperature was not sufficient to be optimal for photosynthesis in the ...
1984-01-01
International water power and dam construction handbook
Energy Technology Data Exchange (ETDEWEB)
The first section of this Handbook describes hydro-electric projects currently under construction or recently commissioned in a number of countries. The major part of the Handbook is devoted to lists of data relating to hydro-electric plants and hydromachinery. These include: data for 1990 submitted by national power authorities on hydro-electric and pumped-storage plants in operation, under construction or planned; more detailed data for pumped-storage plants; country by country data on the dimensions, and reservoir and electrical capacity of major dams and hydro plant; a listing of roller compacted concrete dams; a listing of the world's largest turbines giving data on the largest unit at each scheme in rank order ranging from a unit capacity of 838 MV down to 147 MV; a similar list of the largest hydrogenerators ranging from a unit capacity of 825 MVA down to 150 MVA; details of turbine and generator contracts. The handbook ...
1992-01-01
Development of engineering technology basis for industrialization of pyrometallurgical reprocessing
International Nuclear Information System (INIS)
Development of the engineering technology basis of pyrometallurgical reprocessing is a key issue for industrialization. For development of the transport technologies of molten salt and liquid cadmium at around 500 deg. C, a salt transport test rig and a metal transport test rig were installed in Ar glove box. Function of centrifugal pump and 1/2'' declined tubing were confirmed with LiCl- KCl molten salt. The transport behavior of molten salt was found to follow that of water. Function of centrifugal pump, vacuum sucking and 1/2'' declined tubing were confirmed with liquid Cd. With employing the transport technologies, industrialization applicable electro-refiner was newly designed and engineering-scale model was fabricated in Ar glove box. The electro-refiner has semi-continuous liquid Cd cathode instead of conventional one used in small-scale tests. With using actinide-simulating elements, demonstration of ...
2007-09-09
British Library Electronic Table of Contents (United Kingdom)
Aim/hypothesis We examined whether the renin inhibitor, aliskiren, provides similar or greater protection than ACE inhibition from non-proliferative diabetic retinopathy and from the proliferative neoangiogenesis of oxygen-induced retinopathy. Methods Transgenic (mRen-2)27 rats, which overexpress mouse renin and angiotensin in extra-renal tissues, were studied. For diabetic studies, non-diabetic, diabetic (streptozotocin, 55?mg/kg), diabetic + aliskiren (10?mg?kg?1?day?1, pump), or diabetic + lisinopril (10?mg?kg?1?day?1, drinking water) rats were evaluated over 16?weeks. For oxygen-induced retinopathy studies, rats were exposed to 80% oxygen (22?h/day) from postnatal days?0 to 11, and then room air from postnatal days?12 to 18. Aliskiren (10 or 30?mg?kg?1?day?1, pump) or lisinopril (10?mg...
2011-01-01
Abrasive waterjet machining characteristics of aluminum matrix composites
Energy Technology Data Exchange (ETDEWEB)
Aluminum matrix composite Al356/SiCp(Vol. 15%)(Al MMC) material has been cut under various cutting conditions using Abrasive WaterJet (AWJ) machining process. The experimental cutting was carried out using three different material thicknesses of 10, 20, 30mm with a 0.33mm diameter orifice. The pump pressure, traverse rate, StandOff Distance(SOD) were taken as process parameters. After cutting the quality of the specimen in terms of kerf width, kerf taper, and surface finish were measured to characterize machinability of the material. As a result of the study, the maximum traverse rate for 30mm thick Al MMC under the pump pressure of 350 MPa reached up to 70 mm/min and the surface roughness of the material showed surface finish Ra in the range of 2.3{approx}23.4{mu}m.
2009-07-01
Energy Technology Data Exchange (ETDEWEB)
The Petroleum Technology Transfer Council (PTTC) and cooperating Regional Lead Organizations (RLOs) in its South Midcontinent (Oklahoma Geological Survey, Norman, Oklahoma) and West Coast (University of Southern California, Los Angeles, California) regions conducted a ''Mentor-Based Effort to Advance Implementation of Preferred Management Practices (PMPs) For Oil Producers'' (DE-FC26-01BC15272) under an award in Phase I of Department of Energy's (DOE's) PUMP (Preferred Upstream Management Practices) program. The project's objective was to enable producers in California, Oklahoma and Arkansas to increase oil production, moderating or potentially reversing production declines and extending the life of marginal wells in the near term. PTTC identified the primary constraints inhibiting oil production through surveys and PUMPer direct contacts in both regions. The leading common constraint was excess ...
2004-12-01
High-tech hydro: an overview of pumped storage
A growing number of pumped storage plants installed within the US brings attention to the increasing significance of pumped storage as a source of electrical generation capacity. Because of the special benefits this technology has to offer, hydroelectric pumped storage is an option that many utilities should consider for the supply of new capacity requirements. This article surveys the development and use of pumped storage in the US, and considers the potential for the future development of this technology. Although some of the problems that have occurred on recent projects highlight the role of pumped storage as a technological proving ground, the article puts forth the view that pumped storage is maturing to play a significant role in US electricity supply.
International Nuclear Information System (INIS)
Full text of publication follows: As the coolant experiences no phase change in the core, SCWRs, unlike LWRs, cannot use design criteria based on the critical heat flux concept. The commonly accepted practice in SCWRs is to specify cladding temperature limits that must be met during transient and accident events. Therefore for the design of the SCWR, it is very important to predict the heat transfer coefficient to the supercritical water coolant with great accuracy. Our recent study focuses on the critical issue of measuring heat transfer to supercritical water at prototypical SCWR conditions and to develop the tools to predict the SCWR thermal behavior. A heat transfer test loop using a surrogate fluids, CO_2, is under construction. The reason of using CO_2 instead of water is that (i) valuable insight of the physical phenomena can be ...
2005-10-02
Transient burnout in flow reduction condition
International Nuclear Information System (INIS)
A transient flow reduction burnout experiment was conducted with water in a uniformly heated, vertically oriented tube. Test pressures ranged from 0.5 to 3.9 MPa. An analytical method was developed to obtain transient burnout conditions at the exit. A simple correlation to predict the deviation of the transient burnout mass velocity at the tube exit from the steady state mass velocity obtained as a function of steam-water density ratio and flow reduction rate. The correlation was also compared with the other data. (author).
Means for deriving hydrolized polyacrylonitrile
Energy Technology Data Exchange (ETDEWEB)
A method is proposed for deriving hydrolized polyacrylonitrile from a water-based alkali solution. This process is meant to improve the thermal stability of clay drilling solutions by employing the hydrolized product to treat aliphatic non-water-soluble C/sub 8/-C/sub 16/ spirits in an organic dispersant during the presence of acidity and while the solution is being heated.
1982-01-01
Direct measurements of secondary water inventory of steam generator PGV-213 in operation
Energy Technology Data Exchange (ETDEWEB)
Results of weight measurement of PGV-213 steam generator during filling in, heating-up and power increase are described. Special measurement system based on stress gauges has been developed. Method of derivation of secondary water inventory is described. Comparison of the data for two steam generators prove accuracy of the measurements. (orig.). 1 refs.
1997-12-31
Energy Technology Data Exchange (ETDEWEB)
''Climates of the Oceans'' deals with the atmosphere over the world oceans and provides a treatment not only of the climatic elements such as temperature, pressure, wind, precipitation etc., but also of the circulation of the atmosphere and its changes throughout the year. The connection between sea and overlying air is examined through studies of the water and heat balance. Numerous maps and tables illustrate the elements and their fluctuations over the water and on islands and coasts.
1984-01-01
Energy Technology Data Exchange (ETDEWEB)
A heat pump was tested in the cooling mode under the following conditions: (1) a steady-state test with 95/sup 0/F (35/sup 0/C) outdoor temperature, various indoor conditions, and a dry indoor coil; (2) a steady-state test with 82/sup 0/F (27.8/sup 0/C) outdoor temperature, various indoor conditions, and a dry indoor coil; (3) a cyclic test with an outdoor room temperature of 82/sup 0/F (27.8/sup 0/C), various indoor conditions, and a dry indoor coil. The indoor conditions were varied as follows: (1) indoor temperatures of 75/sup 0/F (23.9/sup 0/C), 80/sup 0/F (26.7/sup 0/C) and 85/sup 0/F (29.4/sup 0/C); (2) volume flowrates over the evaporator coil of 880 cfm (0.47 m/sup 3//s), 1100 cfm (0.52 m/sup 3//s) and 1425 cfm (0.67 m/sup 3//s); (3) during the off-time the dampers were closed in one test series and kept open with a continuously running air handling fan in another test series; (4) the on and off times of the heat ...
1982-05-01
Market assessment for the fan atomized oil burner
Energy Technology Data Exchange (ETDEWEB)
The market potential for the fan atomized burner (FAB) in water and space heating applications was examined. The major findings of the study are as follows. (1). The FAB`s low-input capability allows development of oil-fired room heaters and wall furnaces, a new market area for oil heat. (2). Among conventional oil-fired products, furnaces will benefit most from the burner`s low input capability due to (1) their quick delivery of heat and (2) their more prevalent use in warmer climates and smaller homes. (3). The greatest potential for increased product sales or oil sales exists in the use of the burner with new products (i.e., room heaters). Sales of boilers and direct-fired water heaters are not likely to increase with the use of the burner. (4). Acceptance of the burner will be dependent on proof of reliability. Proof of better reliability than conventional burners would ...
1996-07-01
Interface heat transfer of horizontal co-current liquid-liquid stratified flow
International Nuclear Information System (INIS)
Co-current stratified flow of liquid metal and water was investigated in a horizontal rectangular channel. Position of the interface pressure drop and direct contact heat transfer between these immisci ble liquids were measured in a fully developed flow. A turbulence model was proposed to explain the experimental results considering that the turbulence is damped near the liquid-liquid interface by surface tension. The analytical results showed good agreement with the experimental ones. Main results are that (1) position of the interface mainly depends on the flow rate ratio of both liquids, that (2) the pressure drop is approximately proportional to square of the average velocity of water, and that (3) heat transfer rate at direct contact interface is several times higher than that of co-current flow separated by a thin solid plate. (author).
1980-01-01
International Nuclear Information System (INIS)
The direct injection of steam into a water pool is a method of heat transfer used in many process industries. The amount of research in this area however is limited to the nuclear industry, with applications relating to reactor cooling systems. Electrical resistance tomography (ERT), a low cost, non-invasive and which has high temporal resolution characteristics, can be used as a visualization tool for the resistivity distribution for the steam injection into water pool such as IRWST. In this paper, three dimensional resistivity distribution of the process is obtained through ERT using iterative Gauss-Newton method. Numerical experiments are performed by assuming different resistive objects in the water pool. Numerical results show that ERT is successful in estimating the resistivity distribution for the injection of steam in the water pool
2010-10-01
Energy Technology Data Exchange (ETDEWEB)
In France, groundwater usage represents 40 per cent of volumetric use, outside of thermal power plants. Groundwater represents 60 per cent of domestic and public use, 40 per cent in the industrial sector, and is increasing in the agricultural sector where it accounts for 20 per cent. Groundwater withdrawal in France has slightly increased over the last twenty years and benefited the agricultural sector. Availability throughout the territory, the consistency of resupply and natural quality has rendered groundwater a prevailing source for drinking water. Water protection and management is important and led to the adoption of legislative and regulatory measures. The Mining Code (Code minier) allows for exploitation of underground resources starting at 10 metres. The Rural Code (Code rural) mandates the declaration of public utility for water collection for the public. Protection areas are to be provided under the Public Health ...
2001-07-01
Mode shape and natural frequency identification for seismic analysis from background vibration
International Nuclear Information System (INIS)
Background vibration in a CANDU plant can be used to determine the dynamic characteristics of major items of equipment, such as calandria, the fuelling machines and the primary heat transport pumps. These dynamic characteristics can then be used to verify the seismic response of the equipment which, at present, is based on theoretical models only. The feasibility and basic theory of this new approach (which uses accelerations measured at several points on a structure and does not require knowledge of the source of excitation) was established in Phase I of the study. This report is based on Phase II in which the methods of analysis developed in Phase I were improved and verified experimentally. A Fast Fourier Transform (FFT) algorithm was incorporated and an interactive curve fitting technique was developed to obtain the dynamic characteristics in the form of natural frequencies, mode shapes and damping ratios. The method is now available for ...
1984-02-06
Insights from Development of Regulatory PSA Model for SMART
International Nuclear Information System (INIS)
SMART (System-Integrated Modular Advanced Reactor) is a first-of-the-kind integral reactor with 330 MW thermal power under active development by Korea Atomic Energy Research Institute (KAERI) for power generation and seawater desalination. SMART employs various design features that are not typically found in other nuclear power plants. Examples include a unique passive residual heat removal system (PRHRS), and enclosure of a pressurizer, eight helical steam generators, and eight canned reactor coolant pumps inside the reactor pressure vessel. This paper presents risk insights on the SMART reactor gained during the development of a regulatory PSA model by Korea Institute of Nuclear Safety (KINS)
2010-10-01
An experimental study on stable flow control for multi-stage expansion device
Energy Technology Data Exchange (ETDEWEB)
An Experimental study was performed to investigate flow characteristic of multi-stage expansion valve applied with inverter heat pump. Multi-stage expansion consists of parallel valve which is controlled on/off type of solenoid valve. Expansion valve open one solenoid the other closed in low frequency region and open two solenoid valve in high frequency region. In rated frequency region always open one solenoid valve and control period and on-off time ratio for the other solenoid valve. Flow characteristics of a orifice expansion was measured as a function of orifice diameter and operating conditions. As a results multi-stage expansion device can control a stable flow with period and on-off time ratio. (author). 4 refs., 7 figs., 1 tab.
1998-04-01
Energy Technology Data Exchange (ETDEWEB)
The bibliography contains citations concerning the pitting corrosion of copper and copper alloys, in different media, with some references to methods for protecting against such corrosion. Included are factors contributing to the onset of pitting corrosion. Emphasis is placed on exposure to water, especially in tubing for heat exchangers and water conduits. Many of the citations present studies on exposure to sea water. Some references pertain to the detection of pitting corrosion in installations and the evaluation of the degree of pitting present. (Contains 250 citations and includes a subject term index and title list.)
1993-09-01
Energy Technology Data Exchange (ETDEWEB)
An anaerobic fermenter-decanter for the purification of residual water from the sugar industry, with recovery of methane, consists of a tank with inclined walls, with a central agitator on a vertical shaft. A flexible cover anchored by its periphery to the walls of the tank and totally submerged forms a collecting pocket for the fermentation gases. The water to be purified is introduced, after being heated to about 35, towards the bottom of the tank near the agitator. A metal collecting bell with submerged edges and with the shaft of the agitator passing axially through it is connected by its edges to a central opening of the cover. The purification yields may exceed 90%.
1981-10-06
Surface wettability effect on an indirect evaporative cooling system
Energy Technology Data Exchange (ETDEWEB)
Indirect evaporative air coolers that use air-to-air plate-type heat exchangers show good promise (compared with compression air-conditioning systems) of extending the energy savings from arid, low-humidity areas to more widespread climatic conditions. However, no systematic experiment had been done concerning the effect of the wettability of aluminum plates on the effectiveness of the indirect evaporative cooling system. In this study, a testing apparatus was built where only one secondary channel and two primary channels were used so that different surfaces could be easily tested to determine the system`s effectiveness and the heat transfer coefficient. The advantage of this experimental apparatus is that plates of the heat exchanger can be easily changed in the test section instead of fabricating a complete heat exchanger for each test. A dynamic contact analyzer was used to quantitatively measure ...
1996-11-01
Energy Technology Data Exchange (ETDEWEB)
Numerical investigations of three-dimensional flow and heat transfer in a finned tube with punched longitudinal vortex generators (LVG`s) are carried out for Reynolds number of 250 and 300. Air with a Prandtl number of 0.7 is used as the fluid. The flow is both thermally and hydrodynamically developing. The LVG is a delta winglet pair (DWP) punched out of the fin and is located directly behind the tube, symmetrically separated by one tube diameter. The DWP generates longitudinal vortices in the wake of the tube, defers flow separation on the tube, deflects the main stream into the tube wake, and strong reduces the ``dead water zone.`` Heat transfer reversal is avoided by the DWP. Comparison of the span-averaged Nusselt numbers for the fin with and without DWP shows significant local heat transfer enhancement of several hundred percent in the tube wake. For Re = 300 and Fi = 200 the global ...
1995-08-01
Vacuum system pump down analysis
Energy Technology Data Exchange (ETDEWEB)
My assignment on the SP-100 Vacuum Vessel Vacuum System Team was to perform a transient pump down analysis for the vacuum vessel that will house the SP-100 reactor during testing. Pump down time was calculated for air and helium. For all cases the proposed vacuum system will be able to pump down the vessel within the required time. The use of a larger rotary piston pump (DUO250) improves the pump down time by 35 minutes and therefore should be considered. The 6-inch duct for the roughing line is optimal, however, because all cases are well below the 24 hour time frame, the 4-inch duct is sufficient. The use of the single turbomolecular pump during pump down is sufficient. A pump down with helium in the vessel and a helium inleakage delays the time to achieve the base pressure marginally and is acceptable.
1990-08-01
Energy Technology Data Exchange (ETDEWEB)
Slurry characteristics have a significant impact on centrifugal pump performance. For instance, as particle size increases or the percent solids concentration increases, pump head and efficiency decrease. Therefore, before a slurry pump is selected, it is important to define the slurry characteristics as accurately as possible. The effect of the slurry characteristics on the head and efficiency of the centrifugal pump will be emphasized (the effect on flowrate is less significant). The effect of slurry characteristics is more predominant in smaller pumps (with smaller diameter impellers) than in larger pumps. The data and relationship between the various slurry parameters have been developed from correlations and nomographs published by pump vendors from their field data and test results. The information helps to avoid specifying an ...
1996-11-01
The importance of sodium plume behaviour in the natural convection cooling of fast reactors
International Nuclear Information System (INIS)
This paper relates to a simple approach to the analysis of the behaviour of pool type LMFBR primary circuits in natural convection and to experimental work to support this approach. The primary application is the prediction of plant behaviour in decay heat removal conditions when depending on natural convection effects to cool the core. In formulating a mathematical model of the plant for this application, the main difficulty is the modelling of the large plena between the core and IHX and the IHX and the pump inlet. In a previous paper discussing CDFR behaviour after a reactor scram with total loss of power to the primary pumps, the first author described attempts to model the CDFR hot pool in a way which would be limiting in a pessimistic sense. The shortcomings of these attempts were reviewed and mention was made of an improved method then under development. Essentially, the improved model allowed for migration of hot ...
Method for processing statistical information concerning sucker-rod pump unit operations
Energy Technology Data Exchange (ETDEWEB)
The authors propose an integrated indicator of pump-rod couplings that allows both the couplings and the pump operations to be appraised according to the given formula. (Formula provided). The dynamic relationships of rod operations were determined with nomographs. These relationships involve such factors as: the type and size of the sucker-rod string; the pressure load at the equalizer head and its correlation to threshold pressure at pump discharge; pump diameter; the rod weight and construction; and integral reliability indicators.
1982-01-01
Energy Technology Data Exchange (ETDEWEB)
Products having balanced melting point and decomposition temperature have been developed by employing nylon 6T fundamental molecular structure and selected copolymer components, Arlen being one of the products. It has heat resistance as good as that of super-engineering plastics, low water absorption, and excellent cost-performance which can be used for normal injection molding machines. The unit price per kilogram is low when its high heat resistance is taken into consideration. The coefficient of water absorption is as low as about 1/3 of that of nylon 66, and it can be considered to be a low water absorbing amide. The molding temperature is from 320[degree]C to 350[degree]C, the decomposition temperature is 395[degree]C at 2% weight decreasing temperature, and normal injection molding can be employed. It has excellent soldering resistance, high temperature rigidity, dimensional ...
1994-05-01
International Nuclear Information System (INIS)
A mathematical model is described for determining the level profile along the length of heat exchange tubes in a horizontal steam generator, and for determining the conditions in the steam cushion under the perforated sheet. The water level area is divided in the model into 36 partial elements; for analysis of the conditions under the level, the steam-water space is divided into four areas. The results of the calculations were compared with measurement results for the steam generator rated values. Very good agreement was found. The results show that, among others, the supply water distribution very much affects the conditions in the area of the steam cushion and of the bubble vacuum. Also, the average steam load of the inner bundle tubes is significantly higher than that of the outer bundles. It was also shown that permanent steam generator operation with exposed top tube rows may occur even in some ...
Water in chalk reservoirs: 'friend or foe?'
International Nuclear Information System (INIS)
Most of the petroleum fields in the Norwegian sector of the North Sea are sandstone reservoirs; the oil and gas are trapped in different species of sandstone. But the Ekofisk Field is a chalk reservoir, which really challenges the operator companies. When oil is produced from chalk reservoirs, water usually gets in and the reservoir subsides. The subsidence may be expensive for the oil companies or be used to advantage by increasing the recovery rate. Since 60 per cent of the world's petroleum reserves are located in carbonate reservoirs, it is important to understand what happens as oil and gas are pumped out. Comprehensive studies at the Department of Petroleum Technology and Applied Geophysics at Stavanger University College in Norway show that the mechanical properties of chalk are considerably altered when the pores in the rock become saturated with oil/gas or water under different stress conditions. The processes are ...
Energy Technology Data Exchange (ETDEWEB)
The adaption of the Muster-VAwS (model ordinance on the handling of water endangering substances in plants and specialized facilities) in the ordinances of the different German states, means that the legislator has laid down concrete - technical and organizational - requirements concerning the handling of water-endangering substances for all plants. The present example of the systematic stocktaking of all environmentally relevant substances in the context of the operation of the pumped storage plants of Schluchseewerk AG, Freiburg, an the application of the model operating instructions for hydropower plants shall serve to illustrate two important aspects for the implementation of this extensive ordinance. (orig.) [Deutsch] Durch Umsetzung der Muster-VAwS (Muster-Verordnung ueber Anlagen zum Umgang mit wassergefaehrdenden Stoffen und Fachbetriebe) in entsprechende Laenderverordnungen wurden durch den Gesetzgeber konkrete ...
1998-08-01
Reflux boiling heat removal in a scaled TMI-2 system test facility
International Nuclear Information System (INIS)
An investigation of decay heat removal by the reflux boiling process was performed on a 1/18 linear-scaled test facility simulating the Three Mile Island (TMI-2) primary system. The objective was to clarify reflux boiling phenomena and core cooling effectiveness. Principal test variables included: core power, primary system water and gas inventories, and steam generator secondary-side coolant flow rate. Of 49 tests conducted, 43 achieved a steady-state heat rejection mode within 3 hours. Subsequent analyses identified two distinct reflux boiling modes. Based upon our current understanding, reflux boiling appears to be an effective process for removing decay heat in a broad range of the conditions investigated for a plant of the TMI configuration.
1980-06-01
Process design of the LASL Bismuth Sulfate thermochemical hydrogen cycle
A new process engineering flowsheet reflecting an improved design of the LASL Bismuth Sulfate thermochemical cycle is presented. The design is based on laboratory data that indicate a lowered endothermic heat load for a partial decomposition of the solid bismuth sulfate. A small electrical energy demand should result from operation of the sulfur dioxide electrolytic step at lower acid concentration, in principle. The results of the flowsheeting analysis yield a thermal efficiency of 50% for the cycle when coupled to a conceptual fusion energy heat source at 1500/sup 0/K. A parametric analysis shows a slight drop in efficiency as the temperature of the heat source is decreased. The LASL Bismuth Sulfate thermochemical cycle appears to have potential as a means of producing hydrogen from high-temperature heat sources such as fusion, fission, and solar energy; it also appears to be competitive with ...
1979-01-01
Natural circulation decay heat removal experiments and analysis in an LMFBR fuel assembly
International Nuclear Information System (INIS)
Water flow experiments were conducted on natural circulation decay heat removal with an electrically heated 91-rod bundle. Experimental results were compared with analytical predictions to provide thermal hydraulic characteristics for LMFBR Fuel assemblies under a low flow, typical of the natural circulation regime. The results revealed that, at low flow rate region (Re<1,200), axial friction loss in a heated bundle increases with buoyancy effect. The radial temperature profile provides some insight regarding the concept that coolant redistribution would occur. COBRA-V-I predictions are successfully proved validity in comparison with experimental results.
1982-07-01
Energy Technology Data Exchange (ETDEWEB)
An experimental and theoretical study of heat and mass transfer analogy and a comparison of that to a binary liquid mixture evaporation is presented. Common organic solvents, ethanol and n-heptane, were used to form an alcohol - hydrocarbon mixture. Studies were carried out in a horizontal rectangular channel having air flow velocities of 0.2 - 0.9 m/s. Heat transfer coefficients were measured with a copper plate resistor and mass transfer coefficients with a square pool. The heat and mass transfer analogy is presented for a system having two evaporating compounds with a fixed value of air flow and verified by measuring and comparing mass transfer coefficients for distilled water with air flow velocities of 0.2 - 0.9 m/s. An illustrative example of the use of the theory for industrial ventilation is presented. (author)
1995-12-31
Continuous method development and numerical study of HHV water gas production by pulverized coal
British Library Electronic Table of Contents (United Kingdom)
In energy industries, it is always of difficulty to produce high heat value(HHV) gas continuously using pulverized coal. In this paper, a new type furnace for partitioned alternative gasification using pulverized coal is developed, in which the oxidation and reduction reaction occur alternatively with the dropping of pulverized coal and finally HHV gas could be continuously obtained at the reduction zone exit and low heat value(LHV) gas at the oxidation zone exit. Furthermore, the gasification characteristics and their factors in furnace are numerically simulated under two dimensional model with a self-coded program, based on heat, mass and energy transfer as well as reaction principles. It is found that the producing rate of HHV gas is 1.10Nm3/kg with heat value of 11.72MJ/Nm3, however, t...
2011-01-01
Augmentation of laminar flow and heat transfer in flat tubes by means of helical screw-tape inserts
British Library Electronic Table of Contents (United Kingdom)
The heat transfer a characteristics and friction factor in the horizontal double pipes of flat tubes with full length helical screw element of different twist ratio and helical screw inserts with different spacer length are investigated. Cold and hot water are used as working fluid in tube side and shell side respectively. The experiments covered a range of Reynolds numbers 5.7x102Re1.31x103. The effect of spacer length on the heat transfer augmentation and friction factor and the effect of twist ratio on heat transfer augmentation and friction factor have been presented separately. The study shows that, the Nusslet number (Nu) and friction factor (f) decrease with the increase of S or Y for flat tube. The comparison between the data of present plain circular with that of previous plain ci...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
This article gives an account of the recent development of light water reactors new concepts in the world. Different projects are being studied. The CE80+ from Combustion Engineering (CE) is a 1350 MWe-PWR-type reactor whose primary circuit is confined in a spherical metallic containment. This reactor was certified by NRC (national regulatory commission) in mid-1996. The APWR (advanced pressurized water reactor) is developed by MHI (Mitsubishi heavy industries) in a collaboration with Westinghouse, this PWR-type reactor fitted with 4 loops derived from the SP90 model that was developed by Westinghouse during the eighties. 2 units of ABWR (advanced boiling water reactor) were commissioned in Japan in 1996 and 1997, ABWR was certified by NRC in mid-1996. The BWR90+ is developed by ABB-atom (Sweden) and it represents a cautious advanced version of the BWR75. Passive reactors are reactors that rely only on potential energy ...
2001-07-01
Energy Technology Data Exchange (ETDEWEB)
Two refrains heard in the current retail wheeling debate are that a restructuring of the electric utility industry is inevitable and that its consequences are unpredictable. Notwithstanding the benefits of open competition, there are specific disadvantages of unlimited retail wheeling for some existing independent facilities and especially for hydropower plants. A capital-intensive industry, hydropower is not well-postured to compete effectively in the short-term, against new technologies and fuel sources available in the current marketplace. Hydropower is flat out non-competitive on a price basis with available new capacity. Unless hydro is afforded the same government supports offered to other renewable energy sources, only municipal plants with access to subsidized financing rates and pumped storage plants are going to be built.
1995-03-01
TREATMENT OF RADIOACTIVE EFFLUENTS AT THE MOL LABORATORIES
The cold effluents (sanitary waste and decontaminated radioactive water) are flocculated with sodium phosphate and pumped through a trickling filter. The average decontamination obtained is about 86% for alpha emittera and 76% for beta emitters. The cool effluents (activity < 10/sup -3/ mu c/ml) can be treated by several methods. Provisions have been made for two successive chemical flocculations eventually followed by an adsorptlon. The warm waste treatment (activity between 10/sup -3/ and 1 mu c/ml) is still in the experimental stage. The following methods are used: evaporation for some chemically contaminated wastes, browncoal filtration for reactor effluents, and a combination of chemical treatment and browncoal adsorption in other cases. (auth)
1959-10-31
Silver removal process development for the MEO cleanout
Energy Technology Data Exchange (ETDEWEB)
The Mediated Electrochemical Oxidation (MEO) system is an aqueous process which treats low-level mixed wastes by oxidizing the organic components of he waste into carbon dioxide and water. As MEO system continues to run, dissolved ash and radionuclides slowly accumulate in the anolyte and must be removed to maintain process efficiency. At such time, all of the anolyte is pumped into a still feed tank, and the silver ions need to be removed before sending the solution to a thin-film evaporator for further concentration. The efficiency of removing silver ions in the solution needs to be high enough such that the residual silver sent to Final Forms would be less than 1% wt. The purpose of this work is to develop an efficient process to remove silver ions during the MEO cleanout and to demonstrate the capability of centrifugation for separating small silver chloride particles from the solution. This development work includes lab scale experiments ...
1996-02-01
Prospects of wind energy in Bangladesh
Energy Technology Data Exchange (ETDEWEB)
Wind speed has been measured in Patenga, Cox`s Bazar, Kuakata, Moheshkhali, and Noakhali by the computerized anemometers. The wind computers have been installed at 20 meters height. According to this study annual average wind speeds in the coastal regions of Bangladesh are greater than 6.5 m/s at the height of 20 meters. It has been observed that during day times (8 a.m. to 7 p.m.) wind speeds are about 30 to 40% higher than the average values. The value of the power exponent {alpha} has been determined in the above sites and it is 0.139. So, at 40 meters height the annual average wind speed is about 7.15 m/s. So, wind speeds in the coastal regions of Bangladesh are suitable for both water pumping and electricity generation. Details are given in this paper with graphical and analytical representations. (author)
1996-09-01
Means and method of balancing multi-cylinder reciprocating machines
Energy Technology Data Exchange (ETDEWEB)
A virtual balancing axis arrangement is described for multi-cylinder reciprocating piston machines for effectively balancing out imbalanced forces and minimizing residual imbalance moments acting on the crankshaft of such machines without requiring the use of additional parallel-arrayed balancing shafts or complex and expensive gear arrangements. The novel virtual balancing axis arrangement is capable of being designed into multi-cylinder reciprocating piston and crankshaft machines for substantially reducing vibrations induced during operation of such machines with only minimal number of additional component parts. Some of the required component parts may be available from parts already required for operation of auxiliary equipment, such as oil and water pumps used in certain types of reciprocating piston and crankshaft machine so that by appropriate location and dimensioning in accordance with the teachings of the invention, the virtual ...
1985-01-01
Comparative study in supplying electrical energy to small remote loads in Libya
Energy Technology Data Exchange (ETDEWEB)
The main sources of energy that might be available in remote low populated areas of Libya are either diesel generating units or wind mills for water pumping. Several problems in the working performance of these two types of energy production may arise due to environmental conditions. Direct conversion of solar energy can replace other ways of energy delivery or production, especially in this country where the solar radiation all year is relatively high. Direct conversion of solar energy is relatively expensive, however the cost of erecting long feeders and supervising them may be much more expensive than the usage of solar systems. This paper investigates the economics associated with either solutions of energy production. A case study is given in detail to supply one of the remote areas with a population of about 250. (author)
1998-05-01
Hydrologic Tests at Characterization Wells R-9i, R-13, R-19, R-22, and R-31
Energy Technology Data Exchange (ETDEWEB)
Hydrologic information is essential for environmental efforts at Los Alamos National Laboratory. Testing at new characterization wells being drilled to the regional aquifer (''R wells'') to improve the conceptual hydrogeologic model of the Pajarito Plateau is providing such information. Drilling has been by air-rotary casing-advance or open-hole methods. Most wells are completed with multiple screens. After their construction, wells were rigorously developed by wire-brushing, bailing, followed by surging, swabbing, or jetting, and finally by pumping. These methods are effective based on field-parameter measurements and comparison of results of hydrologic testing at well R-31 before and after complete well development. We conducted field tests on various zones of saturation penetrated by the R wells to collect data needed for determining hydraulic properties. This document provides details of the design and execution of testing as ...
2003-03-01
Heat transfer augmentation for high heat flux removal in rib-roughened narrow channels
International Nuclear Information System (INIS)
Heat transfer augmentation in narrow rectangular channels in a target system is a very important method to remove high heat flux up to 12 MW/m"2 generated at target plates of a high-intensity proton accelerator of 1.5 GeV and 1 mA with a proton beam power of 1.5 MW. In this report, heat transfer coefficients and friction factors in narrow rectangular channels with one-sided rib-roughened surface were evaluated for fully developed flows in the range of the Reynolds number from 6,000 to 1,00,000; the rib pitch-to-height ratios (p/k) were 10,20 and 30; the rib height-to-equivalent diameter ratios (k/De) were 0.025, 0.03 and 0.1 by means of previous existing experimental correlations. The rib-roughened surface augmented heat transfer coefficients approximately 4 times higher than the smooth surface at Re=10,000, p/k=10 and k/De=0.1; friction factors increase around 22 times higher. In this case, higher ...
2001-04-08
Heat transfer augmentation for high heat flux removal in rib-roughened narrow channels
Energy Technology Data Exchange (ETDEWEB)
Heat transfer augmentation in narrow rectangular channels in a target system is a very important method to remove high heat flux up to 12 MW/m{sup 2} generated at target plates of a high-intensity proton accelerator of 1.5 GeV and 1 mA with a proton beam power of 1.5 MW. In this report, heat transfer coefficients and friction factors in narrow rectangular channels with one-sided rib-roughened surface were evaluated for fully developed flows in the range of the Reynolds number from 6,000 to 1,00,000; the rib pitch-to-height ratios (p/k) were 10,20 and 30; the rib height-to-equivalent diameter ratios (k/De) were 0.025, 0.03 and 0.1 by means of previous existing experimental correlations. The rib-roughened surface augmented heat transfer coefficients approximately 4 times higher than the smooth surface at Re=10,000, p/k=10 and k/De=0.1; friction factors increase around 22 times higher. In this case, higher ...
1997-03-01
Energy Technology Data Exchange (ETDEWEB)
The objective of this study is to develop an artificial neural network (ANN) model to predict the thermal conductivity of ethylene glycol-water solutions based on experimentally measured variables. The thermal conductivity of solutions at different concentrations and various temperatures was measured using the cylindrical cell method that physical properties of the solution are being determined fills the annular space between two concentric cylinders. During the experiment, heat flows in the radial direction outwards through the test liquid filled in the annual gap to cooling water. In the steady state, conduction inside the cell was described by the Fourier equation in cylindrical coordinates, with boundary conditions corresponding to heat transfer between the solution and cooling water. The performance of ANN was evaluated by a regression analysis between the predicted and the ...
2009-10-15
Energy Technology Data Exchange (ETDEWEB)
Analyzing various SBLOCA with high pressure safety injection (HPSI) at VVER-440/213, we met a surprising phenomenon - a 'natural' circulation post SG heat transfer reversal. This is not usual, because normal natural circulation (NC) in primary circuit is connected with positive heat transfer at SG. If there is reverse heat transfer at SG (as soon as the break enthalpy outflow is sufficient for removal of reactor decay heat), it should obstruct any natural circulation. The question was, what is the driving force of this 'non-standard natural circulation'. After all we revealed that force - it is the density difference between the colder water in reactor downcomer (cold water from HPSI) and warmer water in inner reactor (lower plenum, core, upper plenum). This phenomenon could be confusing for operating ...
2001-07-01
International Nuclear Information System (INIS)
Analyzing various SBLOCA with high pressure safety injection (HPSI) at VVER-440/213, we met a surprising phenomenon - a 'natural' circulation post SG heat transfer reversal. This is not usual, because normal natural circulation (NC) in primary circuit is connected with positive heat transfer at SG. If there is reverse heat transfer at SG (as soon as the break enthalpy outflow is sufficient for removal of reactor decay heat), it should obstruct any natural circulation. The question was, what is the driving force of this 'non-standard natural circulation'. After all we revealed that force - it is the density difference between the colder water in reactor downcomer (cold water from HPSI) and warmer water in inner reactor (lower plenum, core, upper plenum). This phenomenon could be confusing for operating personal, because there would be an ...
2001-03-20
Selecting the right pumps and valves for flue gas desulfurization
Limestone slurry needs to move efficiently through a complex process, meaning that selecting the right pumps and valves is critical. The article discusses factors to consider in selecting pumps and values for flue gas desulfurization process in coal-fired power plants. 2 photos.
2006-07-15
EDF's experience in the operation of pump-storage plants
Energy Technology Data Exchange (ETDEWEB)
This paper describes the advent of energy pumped storage plants in France, in connection with nuclear power reactors development and gives detailed specifications of different components (pump turbines, alternators, valves ...). 5 figs., 3 tabs.
1992-01-01
A method for acetic processing of an electric, centrifugal well pump
Energy Technology Data Exchange (ETDEWEB)
In order to reduce the length and to increase the effectiveness of processing, the proposed method for acetic processing of an electric centrifugal well pump calls for covering the pressure line during the curing and periodically starting the pump.
1983-01-01
Development and validation of steam generator models for thermal performance monitoring
International Nuclear Information System (INIS)
The thermal performance monitoring and optimization system TEMPO is developed at the OECD Halden Reactor Project. The system supports staff of nuclear power plants in identification and correction of problems, which cause small decreases in plant efficiency but which may lead to significant economical losses. The system-wide physical model consists of mathematical description of individual components, such as the reactor, the pumps, the heat exchangers, or the turbines, etc. TEMPO code has recently been extended with new steam generator (SG) models. The present paper summarizes the thermal-hydraulic modelling aspects of the vertical and the horizontal SG. The heat balance equations and their solution are shown with the appropriate initial and boundary conditions. The method of the calculation of the pressure losses are also introduced. The vertical SG model is based on a U-tube structure and treated as a 1D flow channel. ...
2003-04-20
CFD code fluent turbulence models application. Ansaldo's prototype modeling
International Nuclear Information System (INIS)
Among others, one of the main activities in the Nuclear Engineering and Fluid Mechanics Department of the Engineering School in Bilbao, is the study of liquid metals behavior. And for this purpose the CFD code FLUENT is being used. Currently, the code is being applied to the use of Lead-Bismuth eutectic (LBE) as the coolant of an accelerator driven system (ADS) and also as the target for a neutron source. In this paper, ANSALDO's Energy Amplifier Demonstration Facility is simulated, paying attention only on the coolant. As it will be later explained, natural convection is a very important issue, because the philosophy for safety systems in nuclear devices tends to consider passive technologies. The purpose is to avoid electrical machines like pumps, so the core should remain coolable, even if there is a blackout. To get this natural circulation, heat transfer plays a main role, and as turbulence enhances the heat transfer, ...
2001-12-04
Two Dimensional CFD Analyses on the Heat Transfer for a Supercritical Pressure CO_2
International Nuclear Information System (INIS)
The Supercritical Water Cooled Reactor(SCWR) operates in a pressure around 25MPa and temperature of 293#approx#510 .deg. C. In order to study the heat transfer behaviors and good comparisons between the various fluids, a heat transfer test loop(SPHINX) using CO_2 has been constructed in KAERI as a part of international research program, I-NERI. At a supercritical pressure, the heat transfer coefficient is much larger than that estimated from the Dittus-Boelter correlation for a relatively large flow rate with moderate wall heat flux conditions. This phenomenon was explained by the rapid variations of the physical properties near the wall with the temperature. On the contrary, the heat transfer becomes worse when the bulk fluid enthalpy is below the pseudo-critical enthalpy under a low flow rate with large heat flux conditions. This ...
2005-10-27
In this paper we review and classify the various patterns of isosteric heat versus loading for adsorption of gases on graphitised thermal carbon black at temperatures ranging from below the 3D triple point to temperatures above it, but less than the 3D critical point. We have identified the features of heat curve and highlighted the microscopic origin of these features. The patterns vary with temperature and with the relative strength of the fluid-fluid interaction and solid-fluid interaction. For simple adsorptives (by simple we meant there is no strong association between fluid particles), the heat curve is typified by fluid-fluid attraction and layering phenomena. For adsorptives showing strong association such as water, ammonia and methanol, the heat curve essentially begins below the condensation heat and then approaches it as loading is increased. This is ...
2008-05-24
Energy Technology Data Exchange (ETDEWEB)
A three-dimensional steady numerical computation was made for a component model of fin and tube type of compact heat exchangers situated in a uniform flow. In this study, in order to find a clue to design high-efficient heat exchangers, numerical computation was made in the case where two fences are attached on the plate fin surface and their geometrical effects such as their locations, their heights and their attack angles on flow and heat transfer characteristics were investigated especially in the low Reynolds number range. The effect of a hole, open in the plate fin behind the fence, on heat transfer and flow structures was also examined. This hole simulates the hole of the plate fin to be produced in practical application, when a fence is produced by punching from the original plain fin plate. Two fences with holes were found to show several important effects on flow and heat ...
2000-07-25
Energy Technology Data Exchange (ETDEWEB)
The purpose of the chapter is to explain briefly the various considerations that enter into determining the general layout or arrangement of typical hydroelectric powerplants, pumping plants, and pumped-storage plants. Some of the important factors that affect or determine the location, type, and layout of the plant and the selection of the major items of equipment included in the installation are outlined in this chapter. The first consideration in the design of a powerplant, pumping plant, or pumped-storage plant is that it adequately perform its function and be structurally safe. The structure is also designed to give a pleasing architectural appearance.
1985-05-01
Geothermal Heat Pump Profitability in Energy Services
Energy Technology Data Exchange (ETDEWEB)
If geothermal heat pumps (GHPs) are to make a significant mark in the market, we believe that it will be through energy service pricing contracts offered by retailcos. The benefits of GHPs are ideally suited to energy service pricing (ESP) contractual arrangements; however, few retailcos are thoroughly familiar with the benefits of GHPs. Many of the same barriers that have prevented GHPs from reaching their full potential in the current market environment remain in place for retailcos. A lack of awareness, concerns over the actual efficiencies of GHPs, perceptions of extremely high first costs, unknown records for maintenance costs, etc. have all contributed to limited adoption of GHP technology. These same factors are of concern to retailcos as they contemplate long term customer contracts. The central focus of this project was the creation of models, using actual GHP operating data and the experience of seasoned professionals, to simulate the ...
1997-11-01
Energy Technology Data Exchange (ETDEWEB)
A large amount of industrial water is used for cooling the various process fluids in the petroleum purification factories as well as petroleum chemistry factories. Consequently, a lot of heat exchangers as the necessary constitutional instruments are made of carbon steel. Due to the most of the corrosions of the carbon steel occurring in such cooling water systems are pitting corrosions, the inhibition thereof is extremely important for the elongation of the life of the plants and the stable operation. In this paper, the influences of water quality fractions on pitting corrosion of carbon steel in cooling water circumstance are examined aiming at the fouling in the cooling water. The fouling in the cooling water does not only increase the amount of occurrence of pitting corrosion but also accelerates the progress of pitting corrosion ...
1993-08-15
In situ heat transfer in man-made geothermal energy reservoirs
Energy Technology Data Exchange (ETDEWEB)
Two hot dry rock geothermal energy reservoirs were created by hydraulic fracturing of Precambrian granitic rock on the west flank of the Valles Caldera, a dormant volcanic complex, in the Jemez Mountains of northern New Mexico. Heat was extracted in a closed-loop mode of operation, injecting water into one well and extracting the heated water from a separate production well. The first reservoir was produced by fracturing the injection well at a depth of 2.75 km (9020 ft) where the indigenous rock temperature was 185/sup 0/C. The relatively rapid thermal drawdown of the water produced from the first reservoir, 100/sup 0/C in 74 days, indicated that its effective fracture radius was about 60 m (200 ft). Average thermal power extracted was 4 MW. A second, larger reservoir was created by refracturing the injection well 180 m (600 ft) deeper. Downhole measurements of the ...
1980-01-01
Energy Technology Data Exchange (ETDEWEB)
The important amount of hydration water in the ulexite (NaCaN{sub 5}O{sub 9}.8H{sub 2}O), allows using calcination methods to increase its B{sub 2}O{sub 3} content. This paper analyses the thermal decomposition reaction of a preconcentrated ulexite through weight loss measurements, which occur during the heating of samples until 1000 degree centigree, Determinations of heat content at each temperature were made using an isoperibol calorimeter. The mean specific heat was calculated from these values, and its dependence on temperature was determined. The maximum weight loss was about 32.5% and the specific heat obtained was 1,13 kJ/kg 0 C for solid samples and 1,38 kJ/kg''0 C for fluid samples. The results are useful for the design of the industrial process, in order to determine the thermal requirements for heating calcined ulexite, and to ...
2006-07-01
International Nuclear Information System (INIS)
The super simulator 'SAMPSON' has been developed to show that there exist certain safety margins for light water reactors under hypothetical severe accidents and to investigate realistic measures of accident management by simulating accidents with a parallel computer. Heat-up of fuel rods and release of fission products from fuels are important factors to evaluate source terms. Models for fuel rod heat-up, hydrogen production due to cladding oxidation and cladding deformation and failure in the core region have been developed in the fuel rod heat-up analysis module. Fuel temperatures were calculated by solving the heat conduction equation. The calculated results for fuel temperature and hydrogen production were compared with CORA-13 experiment results. The comparisons showed prediction capability for the heat-up of fuel rods. The fission product release analysis ...
1999-04-19
Application of a finite element method to leak before break (LBB) of a heat exchanger
International Nuclear Information System (INIS)
The leak before break (LBB) concept is difficult to apply to a structure with a thin tube that is immersed in a water environment. A heat exchanger in a nuclear power plant is such a structure. The present paper addresses an application of the LBB concept to a heat exchanger in a nuclear power plant. The minimum leaked coolant amount containing the radioactive material which can activate the radiation detector device installed near the heat exchanger is assumed. The postulated initial flaw size that cannot grow to the critical flaw size within the time period to activate the radiation detector is justified. In this case, the radiation detector can activate the warning signal caused by coolant leakage from initially postulated flaws of the heat exchanger. The nuclear plant can safely shutdown when this occurs. Since the postulated initial flaw size can not grow to the critical flaw ...
2003-08-17
Energy Technology Data Exchange (ETDEWEB)
The present paper is concerned with development and application of a so-called Effective Convection Model (ECM), which aims to provide a detailed, mechanistic description of heat transfer processes in a BWR lower plenum. The ECM is a Computational Fluid Dynamics (CFD)-like tool which employs a simpler and more effective approach to compute heat transfer by solving only energy conservation equation instead of solving the full set of Navier-Stokes and energy equations by a CFD code. We implement the ECM in a CFD code (Fluent), with detailed description of the ECM development, implementation and validation. A dual approach is used to validate the ECM, namely validation against experimental data and against heat transfer results obtained by CFD predictions in the same geometries and conditions. Insights gained from CFD simulations are also used to improve ECM. The ECM capability as an effective tool to simulate ...
2007-07-01
International Nuclear Information System (INIS)
The present paper is concerned with development and application of a so-called Effective Convection Model (ECM), which aims to provide a detailed, mechanistic description of heat transfer processes in a BWR lower plenum. The ECM is a Computational Fluid Dynamics (CFD)-like tool which employs a simpler and more effective approach to compute heat transfer by solving only energy conservation equation instead of solving the full set of Navier-Stokes and energy equations by a CFD code. We implement the ECM in a CFD code (Fluent), with detailed description of the ECM development, implementation and validation. A dual approach is used to validate the ECM, namely validation against experimental data and against heat transfer results obtained by CFD predictions in the same geometries and conditions. Insights gained from CFD simulations are also used to improve ECM. The ECM capability as an effective tool to simulate ...
2007-05-13
British Library Electronic Table of Contents (United Kingdom)
For optimal performances, proton exchange membrane fuel cells require fine water and thermal management. Accurate modelling of the physical phenomena occurring in the fuel cell is a key issue to improve fuel cell technology. Here, an analytic steady state diphasic 2D model of heat and mass transfer is presented. Through this model, the aim of this work is to study the influence of local events on the global performances of a fuel cell. A part of the complete model is a microscopic representation of the coupling between water transport and charge transfers in the electrodes. The thickness of the liquid layer around the reactive agglomerates is deduced from the saturation. The evolution of the quantity of water within the catalyst layer is monitored and its influence on the global performanc...
2010-01-01
Model for simulation of freezing and thawing processes in building materials
Energy Technology Data Exchange (ETDEWEB)
This paper presents a mathematical model for simultaneous heat and moisture transfer under freezing-thawing in porous hygroscopic material. Even below O{sup o}C, unfrozen liquid water exists in the material which plays an important role in the processes. The model takes into account the existence of unfrozen liquid water. The system is treated as a three-(gas, liquid and solid) phase system of water. Moisture chemical potential is used as a moisture potential. Under freezing, moisture chemical potential is a unique function of local temperature. So, during freezing, two unknown variables to be solved are solid water content and moisture potential or temperature. A simple example of simulation for freezing processes is shown. (author)
2001-07-01
Exergy analysis of the solar multi-effect humidification?dehumidification desalination process
British Library Electronic Table of Contents (United Kingdom)
An exergy analysis method is presented of the solar multi-effect humidification?dehumidification desalination (HDD) process. Pinch technology is used in the humidification process to determine the maximum possible saturated air temperature and the temperature of water rejected from the unit, and then the dehumidification process to determine the temperature of water leaving from the heat exchanger. The formulae to calculate the exergy of water and saturated air are given. The solar plane collector is used. From exergy analysis, the solar collector has the lowest exergy efficiency; the HDD process has a lower exergy efficiency, and the water rejected has also a large exergy loss. The energy and exergy recovery rate of the desalination process is also lower. The solar multi-effect HDD proces...
2007-01-01
Underground reservoirs for high-head pumped-storage stations
The advantages of using heads of around 1000 m in conjunction with underground location of the lower reservoirs for pumped storage plants are described, and the possible layouts, equipment, and construction methods are discussed.
1973-03-01
CSCL 10B Unclas G3/03 29020 INFORMATION SERVICE - NASA Technical ...
pumped storage plants; but these must be built as well since there is no correspondence with the pump and turbine operating times governed by normal network ...
Energy Technology Data Exchange (ETDEWEB)
The core bypass phenomenon of borated water injected through direct vessel injection (DVI) nozzles in APR1400 (Advanced Power Reactor 1400MWe) during main steam line break (MSLB) accidents with a reactor coolant pump (RCP) running mode has been simulated using a two-channel and one-dimensional system analysis model code (MARS), and a three-dimensional computational fluid dynamics (CFD) code (FLUENT). A visualization experiment has also been performed using a scaled-down model of the APR1400. The MARS analysis has predicted a serious core bypass phenomenon of borated water, while the CFD analysis has shown results opposite to the MARS results. The CFD analysis has shown that the flow pattern in the downcomer is fully three-dimensional and that vortex flow structures are formed near the cold legs so that the borated water might pass without difficulty into the high flow region of the cold legs and flow ...
2007-04-15
Wax and hydrate control with electrical power
Energy Technology Data Exchange (ETDEWEB)
Electrical heating of subsea flowlines is an effective way to prevent wax and hydrate information, especially for long transportation distances and in low-temperature deep water. Systems are available for use in conjunction with bundles, pipe-in-pipe, and wet-thermal-insulation systems. These systems provide environmentally friendly fluid-temperature control without chemicals or flaring for pipeline depressurizing. Enhanced production is achieved because no time is lost by unnecessary depressurizing, pigging, heating-medium circulation, or removal of hydrate and wax blockages. The seabed temperature at 100-m and greater water depths may range from 7 to {minus}1.5 C, causing a rapid cooling of the hot well streams being transported in subsea flowlines. Under these supercooling conditions, vulnerable crude oils and multiphase compositions will deposit wax and asphalts; also the ...
1997-08-01
Survey of UEC estimates for space heating, DHW heating, and appliances energy usage
Energy Technology Data Exchange (ETDEWEB)
Natural Resources Canada commissioned an informal survey in which 18 organizations, mainly utilities from across Canada were contacted by letter or fax to gather data regarding unit energy consumption (UEC) of space heating, domestic hot water (DHW) heating and appliances. The data was used in updating and refining the residential energy end-use model used at NRCan. The survey included energy load, UEC, efficiency, and per cent saturation for both space heating and water heating equipment for all fuel types including electric, natural gas, oil, wood and propane used in single detached, single attached, apartment and mobile homes. A list of UEC and per cent saturation for major appliances such as refrigerators, freezers, clothes washers and dryers, cooktop/ovens, central air-conditioners, and lighting is also included in the survey. The collected data was ...
1998-03-01
Two-fluid modeling of condensation in the presence of noncondensables in two-phase channel flows
Energy Technology Data Exchange (ETDEWEB)
Condensing two-phase channel flow occurs in many industrial applications, including heating and refrigeration systems. It can also occur in certain nuclear reactor accidents. For example, during a small-break loss-of-coolant accident in a pressurized water reactor, following the partial depletion of the primary coolant, condensation of steam on the primary side of the steam generator tubes can provide a heat sink for disposal of the decay heat generated in the reactor core. Condensing two-phase flow can also play an important role in the operation of the passive emergency cooling system in the advanced simplified boiling water reactor. Here, steady-state condensation in the presence of a noncondensable in a concurrent two-phase channel flow is analyzed using a two-fluid model. The effect of noncondensables on the combined heat transfer at the liquid-gas mixture ...
1995-01-01
Thermal stress cracking and the enhancement of heat extraction from fractured geothermal reservoirs
Given sufficient time, the extraction of heat from geothermal reservoirs formed by the hydraulic fracturing of competent rock will eventually result in the formation of thermal stress cracks in the reservoir. These cracks penetrate the rock in a manner such that the penetration-to-spacing ratio is approximately one. The penetration depends upon the extent of cooling and the square root of time. Initially then, the cracks are closely spaced and penetrate but little, so that a crazing pattern is apparent; but with increasing time some of these cracks, now more widely spaced, grow deeper. Eventually these larger cracks attain a critical aperture such that significant rates of water flow can be established within them and thus the newly created heat transfer area becomes useful for heat extraction. At the same time that cracks are forming within the main reservoir, thermal cracking also occurs in the ...
1978-04-01
Heavy water reactor facility large-scale containment cooling test program
The Heavy Water Reactor Facility (HWRF), as part of the defense-in-depth philosophy to mitigate the effect of design-basis and severe accidents, is equipped with a passive containment cooling system (PCCS). The function of the PCCS is to provide a safety-grade path to the ultimate heat sink for the removal of the reactor coolant system sensible heat and core decay heat. Ambient air enters an annular space between the steel containment shell and the surrounding concrete shield building through inlets in the shield building wall, is heated via natural convection, rises, and exits the building through a chimney located above the containment dome. A test program is in place to access parameters important to the effective operation of the PCCS. This paper focuses on the large-scale tests (LSTs). The objectives of these tests are as follows: (1) demonstrate natural circulation cooling ...
1992-01-01
Heavy water reactor facility large-scale containment cooling test program
International Nuclear Information System (INIS)
The Heavy Water Reactor Facility (HWRF), as part of the defense-in-depth philosophy to mitigate the effect of design-basis and severe accidents, is equipped with a passive containment cooling system (PCCS). The function of the PCCS is to provide a safety-grade path to the ultimate heat sink for the removal of the reactor coolant system sensible heat and core decay heat. Ambient air enters an annular space between the steel containment shell and the surrounding concrete shield building through inlets in the shield building wall, is heated via natural convection, rises, and exits the building through a chimney located above the containment dome. A test program is in place to access parameters important to the effective operation of the PCCS. This paper focuses on the large-scale tests (LSTs). The objectives of these tests are as follows: (1) demonstrate natural circulation cooling ...
1992-11-15
Engineering design of cryocondensation pumps for the DIII-D Radiative Divertor Program
Energy Technology Data Exchange (ETDEWEB)
A new double-null, slotted divertor configuration will be installed for the DIII-D Radiative Divertor Program at General Atomics in late 1996. Four cryocondensation pumps, three new and one existing, will be part of this new divertor. The purpose of the pumps is to provide plasma density control and to limit the impurities entering the plasma core by providing pumping at each divertor strike point. The three new pumps are based on the design of the existing pump, installed in 1992 as part of the Advanced Divertor Program. The pump continues to operate successfully. The new pumps require geometry modifications to the original design. Therefore, extensive modal and dynamic analyses were performed to determine the behavior of these pumps and their helium and nitrogen feed lines during disruption events. Thermal and fluid ...
1995-12-31
Engineering design of cryocondensation pumps for the DIII-D Radiative Divertor Program
International Nuclear Information System (INIS)
A new double-null, slotted divertor configuration will be installed for the DIII-D Radiative Divertor Program at General Atomics in late 1996. Four cryocondensation pumps, three new and one existing, will be part of this new divertor. The purpose of the pumps is to provide plasma density control and to limit the impurities entering the plasma core by providing pumping at each divertor strike point. The three new pumps are based on the design of the existing pump, installed in 1992 as part of the Advanced Divertor Program. The pump continues to operate successfully. The new pumps require geometry modifications to the original design. Therefore, extensive modal and dynamic analyses were performed to determine the behavior of these pumps and their helium and nitrogen feed lines during disruption events. Thermal and fluid ...
1995-10-01
Energy Technology Data Exchange (ETDEWEB)
The further optimisation and improvement of the efficiency of internal combustion engines require the realisation of new technologies leading to a distinctively faster warm-up behaviour of the coolant and lubricants as well as of the engine components after a cold start. In order to achieve reduced fuel consumption and exhaust gas emissions with the help of heat management, the design criteria of innovative cooling systems need to be reflected and adapted to future requirements. The use of intelligent components within the cooling system, such as the 'Stand Alone Rotary Valve' as a thermostat's substitute or the use of coolant pumps with a rotary valve integrated into the pump's inlet chamber, offer new ways to realise in a decisively quicker and more flexible way the appropriate heating up and cooling down procedures at varying driving conditions. A description of ...
2001-07-01
Energy Technology Data Exchange (ETDEWEB)
Due to its important hydroelectric power generation facilities (about 525 plants with a total power of 13,314 MW producing about 35.3 TWh annually) Switzerland plays an important role in the interconnected European power system. Large artificial storage lakes in the Swiss Alps can generate peak power during hours of highest demand: 9700 MW are available from accumulated energy and the total power of pumped-storage facilities amounts to 1700 MW. The latter allow refilling the reservoirs at periods of low power demand and generating power at periods of peak demand. In the case of favorable conditions, the yearly average power production could be increased by 6% and the production during the winter period (October to March) by 20% by the year 2020. However, looking forward to the year 2050, the annual production is expected to decrease by 3% despite a possible extension of hydropower. This decrease is due to the enforcement of the minimum residual ...
2007-07-01
Two-phase Flow Regime Maps in Horizontal and Vertical Tubes
Energy Technology Data Exchange (ETDEWEB)
A safety analysis code to design a pressurized water reactor and to obtain the licenses including entire proprietary rights is under development in domestic R and D project. The tasks of KAERI is to develop the constitutive relations including models for defining flow regimes and flow regime related models for inter-phase friction, wall frictions, wall heat transfer, and interphase heat and mass transfer in the two-phase three-field equations. In this paper, the process will be presented for choosing the best flow regime maps which occur in gas-liquid two-phase flow in horizontal and vertical tubes.
2007-10-15
Two-phase Flow Regime Maps in Horizontal and Vertical Tubes
International Nuclear Information System (INIS)
A safety analysis code to design a pressurized water reactor and to obtain the licenses including entire proprietary rights is under development in domestic R and D project. The tasks of KAERI is to develop the constitutive relations including models for defining flow regimes and flow regime related models for inter-phase friction, wall frictions, wall heat transfer, and interphase heat and mass transfer in the two-phase three-field equations. In this paper, the process will be presented for choosing the best flow regime maps which occur in gas-liquid two-phase flow in horizontal and vertical tubes.
2007-10-01
Overview of US LMFBR Structural Materials Mechanical Properties Program
Energy Technology Data Exchange (ETDEWEB)
This paper presents the objective, scope, and status of the US Department of Energy's Materials and Structures Program to develop a data base on mechanical properties of structural materials for out-of-core structures and components for LMFBRs. Information on the development of a reference data base on materials for the reactor system, reactor enclosure system, primary heat transport system, intermediate heat transport system, and steam generator system is included. In addition, the development of the data and analyses to account for the effects of temperature and stress, as well as water/steam, sodium, and radiation environments, is described. Plans for the development of alternative materials for future out-of-core applications are presented.
1983-01-01
Overview of U.S. LMFBR structural materials mechanical properties program
International Nuclear Information System (INIS)
This paper presents the objective, scope, and status of the U.S. Department of Energy's Materials and Structures Program to develop a data base on mechanical properties of structural materials for out-of-core structures and components for LMFBRs. Information on the development of a reference data base on materials for the reactor system, reactor enclosure system, primary heat transport system, intermediate heat transport system, and steam generator system is included. In addition, the development of the data and analyses to account for the effects of temperature and stress, as well as water/steam, sodium, and radiation environments, is described. Plans for the development of alternative materials for future out-of-core applications are presented. (author).
1983-10-10
Improvement of FLOWER code and its application in Daya Bay
International Nuclear Information System (INIS)
FLOWER, a computer code recommended by USNRC for assessing the environmental impact in tidal regions, was adapted and improved so as to be suitable to deal with the influence of drift stream along seashore to the dilution of contaminants and heat in the bay mouth. And the code outputs were presented with more mid-results such as average concentrations and temperature values for all tides considered. Finally, the modified code is applied to the dispersion calculation of heat and liquid effluents from Daya Bay Nuclear Power Plant, and the impacts from routine operation of the plant on Daya Bay sea waters were given.
Heat recovery in polyester production: a case study
Energy Technology Data Exchange (ETDEWEB)
Energy savings in the synthetic fiber industry could be realized by using autoclave reactor condensate and boiler flue gas heat recovery. The non-cellulose (polyester) production process analysis shows that condensate returning from the reactor to the steam boiler raises inlet temperature, giving a reduced fuel requirement of about 8%. Also, boiler flue gas with a sufficiently high outlet temperature for boiler feed water and combustion air preheating results in further fuel savings. The process with an economizer saves up to 8.44%, and with a combustion air preheater, 6.25%. (Author)
1997-07-01
Geothermal resource assessment of the New England states
Energy Technology Data Exchange (ETDEWEB)
With the exception of Sand Springs in Williamstown, Massachusetts, there are no identifiable hydrothermal geothermal resources in the New England region. The radioactive plutons of the White Mountains of New Hampshire do not, apparently, contain sufficient stored heat to make them a feasible target for an induced hydrothermal system such as exists at Fenton Hill near Los Alamos, New Mexico. The only potential source of low grade heat is the large volume of ground water contained within the unconsolidated sediments related to the Pleistocene glaciation of the region. During the course of the survey an unusual and unexplained thermal anomaly was discovered in St. Johnsbury, Vermont, which is described.
1982-01-01
Flow Regime Map Models for the Horizontal and Vertical Pipes for the SPACE code
Energy Technology Data Exchange (ETDEWEB)
A safety analysis code, named as SPACE, for a pressurized water reactor is under development to obtain a licensing to be used for the PWR design and to hold entire proprietary rights. The task of KAERI is to develop the physical models and correlations which are required to solve the field equations. It can be divided into four parts; i) flow regime determination, ii) wall heat transfer, iii) wall and interfacial friction, iv) interfacial heat and mass transfer. This paper will describe the process to develop the models for the two-phase flow regime maps in the horizontal and vertical pipes.
2008-05-15
Flow Regime Map Models for the Horizontal and Vertical Pipes for the SPACE code
International Nuclear Information System (INIS)
A safety analysis code, named as SPACE, for a pressurized water reactor is under development to obtain a licensing to be used for the PWR design and to hold entire proprietary rights. The task of KAERI is to develop the physical models and correlations which are required to solve the field equations. It can be divided into four parts; i) flow regime determination, ii) wall heat transfer, iii) wall and interfacial friction, iv) interfacial heat and mass transfer. This paper will describe the process to develop the models for the two-phase flow regime maps in the horizontal and vertical pipes.
2008-05-01
Core preservation with a laminated, heat-sealed package
Energy Technology Data Exchange (ETDEWEB)
A core preservation package was developed to maintain the reservoir characteristics of core samples and consequently to improve the quality of data obtained through laboratory core analyses. The package is a heat-sealable plastic-aluminum laminate similar to those common in the food-packaging industry. The laminated core preservation package acts as an impermeable barrier to water vapor and gases, and is resistant to chemical alteration and degradation by core fluids. These performance characteristics result in effective core preservation by maintaining the fluid content of the core. Other advantages of the laminated package are that it is fast and simple to use and eliminates the cumbersome dip-coat step used in some core preservation methods.
1988-12-01
A mathematical model for a thermally coupled humidification?dehumidification desalination process
British Library Electronic Table of Contents (United Kingdom)
The humidification?dehumidification process is an interesting technique that has been adapted for water desalination. Previous works experimentally investigated desalination processes in the shell and tube columns, where the humidification and dehumidification were thermally coupled and simultaneously performed at the tube and shell sides, respectively. In this work, a comprehensive steady-state mathematical model was developed for such a humidification?dehumidification desalination process by taking into account the heat and mass balances on both sides of the desalting column, the mass transfer rate at the humidification side, and the heat transfer rate between the dehumidification side and humidification side. Meanwhile, the mass transfer coefficient at the humidification side and the to...
2006-01-01
Energy Technology Data Exchange (ETDEWEB)
This project of law concerns an additional protocol to the agreement of warranties signed on September 22, 1998 between France, the European atomic energy community and the IAEA. This agreement concerns the declaration of all information relative to the R and D activities linked with the fuel cycle and involving the cooperation with a foreign country non endowed with nuclear weapons. These information include the trade and processing of nuclear and non-nuclear materials and equipments devoted to nuclear reactors (pressure vessels, fuel loading/unloading systems, control rods, force and zirconium tubes, primary coolant pumps, deuterium and heavy water, nuclear-grade graphite), to fuel reprocessing plants, to isotope separation plants (gaseous diffusion, laser enrichment, plasma separation, electromagnetic enrichment), to heavy water and deuterium production plants, and to uranium conversion plants. (J.S.)
2002-10-01
Fifteenmile Basin habitat enhancement project : annual report FY 1990.; ANNUAL
International Nuclear Information System (INIS)
The goal of the Fifteenmile Creek Habitat Improvement project is to improve wild winter steelhead habitat in the Fifteenmile Creek Basin. This goal was addressed under the Columbia River Basin Fish and Wildlife Program, Measure 703 (c) (1) - Action Item 4.2. Construction of fish habitat structures was completed on approximately 3.5 miles of Eightmile Creek and on approximately 8.5 miles of Fifteenmile Creek. A total of 15,435 yds of rock was placed to improve rearing and spawning habitat, and to improve water quality and reduce siltation. Riparian protection fencing was completed on 1.8 miles of Dry Creek, approximately 1.75 miles on Eightmile Creek, and 4.75 miles on Fifteenmile Creek. Approximately 10 miles of stream will receive protection from the 8 miles of new fencing installed and 6.5 miles of abandoned fence repaired. Irrigation withdrawal screens were installed at six irrigation pump withdrawals. These screens functioned satisfactorily ...
International Nuclear Information System (INIS)
Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by Deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on Tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-3 and 4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)
2006-11-13
International Nuclear Information System (INIS)
Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)
2005-11-23
Recriticality of a BWR core during reflood after control blade meltdown
Energy Technology Data Exchange (ETDEWEB)
In nuclear reactor safety research, the question of the possible consequences of delayed core reflood during severe accidents or anticipated transient without scram transients in boiling water reactors (BWRs) has been raised. One can envisage a very low probability accident scenario leading to core uncovery and core heat-up, followed by control blade melting and subsequential delayed reflooding of the core with unborated water before its degradation. Reflooding of the hot core causes significant increases in the peak heating, melting, and hydrogen production rates, thus increasing the probability of core degradation. However, as has been established, debris beds formed from shattered fuel rods and quenched fuel melt will be undermoderated. The reflood process of a voided, intact core was examined using the TRAC/BFI CODE.
1994-12-31
A model of chemistry and thermal hydraulics in PWR fuel crud deposits
Energy Technology Data Exchange (ETDEWEB)
A model is described for simulating thermal hydraulic and chemical conditions within fuel crud deposits. Heat transfer takes place by wick boiling in which water flows through the porous deposit and evaporates into steam at the surface of chimneys. The transport and chemistry of dissolved species within the deposit is also modelled. This chemistry includes the equilibrium chemistry of Li/boric acid species, the equilibrium chemistry of Fe/Ni species and the radiolysis chemistry of water. The unique feature of this model is that the chemistry is coupled to the thermal hydraulics via the increase in the saturation temperature with the concentration of dissolved species. This has a profound effect on evaporative heat transfer within thick deposits, leading to conditions that explain the precipitation of LiBO{sub 2} and the possible formation of bonaccordite. The model helps understand several crud scrape ...
2006-07-01
Review of JT-60U experimental results from February to October, 1999
International Nuclear Information System (INIS)
In 1999, the plasma parameters of reversed shear (RS) plasmas had been extended in 1) DT-equivalent fusion power gain Q_D_T"e"q - 0.5 (n_D(0)#tau#_ET_i(0) - 4x10"2"0 m"-"3#centre dot#keV#centre dot#s) for 0.8 s and 2) full non-inductive current drive with 80% of the bootstrap current fraction. Physics of the internal transport barriers (ITBs) in RS plasmas, including the energy transport and the formation of ITB, were extensively studied. A nearly full current drive (92% non-inductively) was obtained with negative ion based neutral beam (NNB) injection (360 keV, 3.4 MW) in a high #beta#_p H-mode plasma (I_p=1.5 MA, B_T=3.7 T, q_9_5=4.2) with high plasma performance (#beta#_N=2.4 and H_8_9=2.56). Rise in the central electron temperature (T_e - 9 keV) resulted in the current drive efficiency #eta#_C_D of NNB reached 1.3x10"1"9 A/W/m"2, the highest for the neutral beam current drive. As for the H-mode plasmas, decrease in the pedestal ion temperature due to strong gas was found cause ...
1994-06-01
Energy Technology Data Exchange (ETDEWEB)
World-wide water scarcity, especially in the developing world, indicates a pressing need to develop inexpensive, decentralized small-scale desalination technologies which use renewable resources of energy. This paper provides a comprehensive review of the state-of-the-art in one of the most promising of these technologies, solar-driven humidification-dehumidification (HDH) desalination. Previous studies have investigated many different variations on the HDH cycle. In this paper, performance parameters which enable comparison of the various versions of the HDH cycle have been defined and evaluated. To better compare these cycles, each has been represented in psychometric coordinates. The principal components of the HDH system are also reviewed and compared, including the humidifier, solar heaters, and dehumidifiers. Particular attention is given to solar air heaters, for which design data is limited; and direct air heating is compared to direct ...
2010-05-15
Energy Technology Data Exchange (ETDEWEB)
In order to investigate pitting corrosion of copper coiled tubes for air conditioning systems with an open heat storage water tank, the effect of carbon films on the inner surface of copper tubes and fine corrosion-product particles in water as environmental corrosion factor on pitting corrosion was studied by field test under real environmental conditions. As a result, pitting corrosion of copper tubes was caused by synergistic effect of fine corrosion-product particles in water and carbon films. Generation of pitting corrosion was derived from deposition of the films and particles, while considerable growth of pitting corrosion was dependent on the particles. Time variation of spontaneous electrode potential also showed the effect of the film and particle. Pitting corrosion potential was estimated to be nearly 100mV vs. SCE. The following measures against pitting corrosion were considered to be ...
1998-11-15
3D-nuclear heat generation in PCC-charcoal filter in TAPP-3 and 4
International Nuclear Information System (INIS)
This paper deals with the calculations of 3D nuclear heat generation profile in the charcoal filter and subsequently the commencement time of Primary Containment Cleanup (PCC) system of 540MWe Pressurized Heavy Water Reactor (PHWR). Fuel failure is predicted due to overheating of the fuel under loss of Coolant Accident (LOCA) without Emergency Core Cooling System (LOCA without ECCS). Subsequently fission product gasses along with water vapours are released to Reactor Building (RB) atmosphere. Plate-out and water trapping mechanism stabilizes the concentration of significant fission products i.e. radioiodines in about 4 hours before being circulated through charcoal filters of Containment Cleanup system. After cleaning up the RB atmosphere, it is discharged to outside atmosphere through stack. The isotopes of radioiodine emit beta and gamma radiations. Gamma radiations are partly stopped within the ...
2006-11-13
Energy Technology Data Exchange (ETDEWEB)
Full text of publication follows: The heat transfer and flow in narrow channels has lots of advantages such as compact structure, high efficiency, design flexibility and so on. So it is widely used in the fields such as the new reactor core plate elements, the once-through stream generator, compact heat exchangers as well as electronic components. In recent years, more strong attentions have been attracted to the thermal-hydraulic characteristics and mechanism of the two-phase flow in narrow channels. As the flow regime characteristics of two-phase flow is fundamental one of them, the research on the two-phase flow regimes and the regime transitions in horizontal rectangular narrow heated channels can provide theoretical foundation and engineering directions to the whole research on the thermal-hydraulic characteristics and mechanism of the two-phase flow in narrow channels. The characteristics of two-phase flow regimes and ...
2005-07-01
International Nuclear Information System (INIS)
Full text of publication follows: The heat transfer and flow in narrow channels has lots of advantages such as compact structure, high efficiency, design flexibility and so on. So it is widely used in the fields such as the new reactor core plate elements, the once-through stream generator, compact heat exchangers as well as electronic components. In recent years, more strong attentions have been attracted to the thermal-hydraulic characteristics and mechanism of the two-phase flow in narrow channels. As the flow regime characteristics of two-phase flow is fundamental one of them, the research on the two-phase flow regimes and the regime transitions in horizontal rectangular narrow heated channels can provide theoretical foundation and engineering directions to the whole research on the thermal-hydraulic characteristics and mechanism of the two-phase flow in narrow channels. The characteristics of two-phase flow regimes and ...
2005-10-02
Spattering and Crackle of Hot Cooking Oil with Water: A Classroom Demonstration and Discussion
Any student that has spent time in the kitchen knows that hot vegetable oil will pop and spatter violently after coming into contact with water such as that on the surface of foods (meat, fish, potatoes, etc.). This well-known effect can be used as an instructional resource to promote cooperative, active, and inquiry-based learning about central concepts of chemistry including boiling point, miscibility, and density of liquids. The starting point of the learning activity is a demonstration of (i) the effect of adding a drop of water to hot (as for cooking) vegetable oil and (ii) the effect of adding a drop of vegetable oil to hot water (near its boiling point). Intermolecular interactions, properties of vegetable oils, and a variety of other topics, such as the importance of other heat points (smoke, flash, and fire) for oils, the fundamental of the crackle test for checking the presence of ...
2009-11-01
Modeling of thermal and hydrodynamic aspects of molten jet/water interactions
Energy Technology Data Exchange (ETDEWEB)
In order to predict the effect of a fuel-coolant interaction after a hypothetical core-melt-down accident, a phenomenological model has been developed to describe the thermal and hydrodynamic behavior of a high-temperature molten jet when it interacts with saturated or subcooled water in a film boiling regime. The mechanisms of jet-material erosion were analyzed by Kelvin-Helmholtz instabilities on the coherent column and by boundary layer stripping on the leading edge. The heat transfer coefficient, vapor-film thickness, and net steam generation, all of which strongly affect the jet-breakup behavior, were solved analytically. It was found that the jet breakup (or erosion) depends strongly on the steam generation from the jet/water interaction. The jet-breakup length (i.e., penetration distance) was found to be sensitive to the initial jet temperature, water subcooling, and the physical state of the ...
1989-01-01
Energy Technology Data Exchange (ETDEWEB)
This report summarizes work performed by Argonne National Laboratory on fatigue and environmentally assisted cracking (EAC) in light water reactors from January 1997 to June 1997. Topics that have been investigated include (a) fatigue of carbon, low-alloy, and austenitic stainless steels (SSs) used in reactor piping and pressure vessels, (b) irradiation-assisted stress corrosion cracking of Types 304 and 304L SS, and (c) EAC of Alloys 600 and 690. Fatigue tests were conducted on ferritic and austenitic SSs in water that contained various concentrations of dissolved oxygen (DO) to determine whether a slow strain rate applied during various portions of a tensile-loading cycle is equally effective in decreasing fatigue life. Slow-strain-rate-tensile tests were conducted in simulated boiling water reactor (BWR) water at 288 C on SS specimens irradiated to a low fluence in the Halden reactor and the results ...
1998-04-01
Heat Transfer Enhancement of Nanofluid in Natural Convection of an Enclosure Heated from Below
Energy Technology Data Exchange (ETDEWEB)
The general strategy for improving the safety of nuclear power plant and its economics is to accomplish power uprates while securing sufficient thermalhydraulic margin. In order to succeed this strategy, there have been a lot of efforts in increasing the margin through the enhancement of heat transfer capability in coolants. However, despite their efforts, only about 10 {approx} 15 % increase of the thermal margin is possible by using the best art known well up to now with installation of mechanical engineering devices such as mixing vane or button to generating the swirl flow and turbulent mixing. The limit of the capability of the best technique has made a lot of engineers to be frustrated to do the power uprates. Nevertheless, fortunately a new innovative idea is being proposed in heat transfer community as an engineering colloidal fluid to basically change the original properties of the coolant. The fluid began to be called by Choi as a ...
2005-07-01
The solar energy in Lebanon: an inexhaustible and economical energy
International Nuclear Information System (INIS)
The article describes the energy in Lebanon. In 1995, 97% of the imported energy was based on hydrocarbons. Fuel and gas oil present 66% of the final energy. Air pollution is mainly caused by the transportation sector (vehicles and buses...) which presents 70% of the global atmospheric pollution. Renewable energy such as biomass, fossil energy, hydro-energy, solar energy... are also described. The solar energy was defined as a best solution that preserve health in Lebanon. The different applications of the solar for energy production is discussed: photovoltaic , thermal heating, sanitary hot water, electrical heaters, solar water heaters...In conclusion, solar heaters economize 80% of the annual energy expenses
1997-06-01
Energy Technology Data Exchange (ETDEWEB)
The bibliography contains citations concerning the pitting corrosion of copper and copper alloys by different media, with some references to methods that protect against such corrosion. Included are factors contributing to the onset of pitting corrosion. Emphasis is placed on exposure to water, especially in heat exchanger tubing and water conduits. Studies are included which examine corrosion in metals containing small amonts of copper where corrosion is attributable to changes in alloying. (Contains a minimum of 158 citations and includes a subject term index and title list.)
1994-04-01
Lightweight bricks manufactured from water treatment sludge and rice husks.
Novel lightweight bricks have been produced by sintering mixes of dried water treatment sludge and rice husk. Samples containing up to 20 wt.% rice husk have been fired using a heating schedule that allowed effective organic burn-out. Rice husk addition increased the porosity of sintered samples and higher sintering temperatures increased compressive strengths. Materials containing 15 wt.% rice husk that were sintered at 1100 degrees C produced low bulk density and relatively high strength materials that were compliant with relevant Taiwan standards for use as lightweight bricks. PMID:19596512
2009-06-17
Energy Technology Data Exchange (ETDEWEB)
Thermal solar energy plants for water heating have experienced an enormous boom during the last years. Thus, a total of 200000 square metres of collector surface was installed on German rooves in 1991. This was three times as much as in the year before. And this trend of conserving natural resources by using the energy of the sun is still undiminished. (orig.)
1993-11-01
International Nuclear Information System (INIS)
Unit one of Daya Bay, China's first nuclear power plant was officially opened in February 1994. The nuclear island has been built by Framatome and is an improved version of the Gravelines 5 and 6, 900MWe Pressurized Water Reactors. Extra seismic protection has been included because of greater earthquake risk. The heat exchanger capacity has also been increased as the sea cooling water can be at 30"oC. The technical specifications and details of the fuel loading are given. The technical assistance, management and training of Chinese personnel are discussed. Two further units may be built if Daya Bay 1 is successful. (UK).
Causes of denting. Volume 5. Contaminant threshold tests. Final report
Steam generators in PWR plants have been subject to denting corrosion as a result of nonprotective magnetite forming on the carbon steel support plate causing the voluminous corrosion product that eventually crimps (dents) the heat transfer tube at the support plate interface. This project was designed to determine the causes of denting and the usefulness of water chemistry changes meant to arrest denting. This volume of the final report describes laboratory research on the correlation of water chemistry, superheat, and oxygen ingress with denting in steam generators.
1983-12-01
A horizontal steam generator for the Indian 235 MW heavy water nuclear power plants
International Nuclear Information System (INIS)
In this paper the thermal design of a horizontal steam generator for the Indian PHWR nuclear power plant is described. The main attraction is absence of tube sheet and use of stainless steel 'U' tubes. It is emphasised that with appropriate water chemistry it is possible to use stainless steel tubes, which is many times cheaper than the Incoloy tubes used elsewhere. The design approach, applicable equation for the design and the results of computation in the form of heat transfer area and some important dimensions of the steam generator are presented.
1993-11-01
Unsteady-state flow of methane and water in coal beds
Energy Technology Data Exchange (ETDEWEB)
A hypothesis on the transition of a fully water-saturated coal bed methane reservoir from single-phase flow through unsaturated flow to the two-phase flow regime was developed and substantiated using field data. The concept of parameter measurement windows was introduced to obtain the required reservoir parameters from flow testing. A new empirical relationship for capillary pressure vs. saturation, referred to as the Fermi distribution, was developed and shown to fit the capillary pressure-saturation data for coal, sandstone, and other consolidated and unconsolidated materials. New approximate analytic solutions for flow to a sink from an infinite coal bed reservoir with desorbing methane have been developed and verified using numerical models for the following cases: (1) single-phase gas flow with desorption; (2) single-phase water flow in fully water-saturated and unsaturated flow regimes. A numerical model based on ...
1987-01-01
Measurements of radon concentration levels in drinking water at urban area of Curitiba, Brazil
International Nuclear Information System (INIS)
Current work presents the results of more than 100 measurements of 222Rn activity in drinking water collected at artesian bores at Curitiba region during the period of 2008 - 2009. The measurements were performed at the Laboratory of Applied Nuclear Physics of the Federal University of Technology in cooperation with the Nuclear Technology Development Center (CDTN) of Brazilian Nuclear Energy Committee (CNEN). Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specific kit of glass vessels Aqua KIT through the air pump. The equipment was adjusted with air flow of 0.5 L/min. The 222Rn concentration levels were detected and analyzed by the computer every 10 minutes using the software DataEXPERT by GENITRON Instruments. Collected average levels of 222Rn concentration were processed taking into account the volume of water sample and its temperature, atmospheric pressure and the total volume ...
International Nuclear Information System (INIS)
Design improvements are being incorporated into the heavy water management systems at Wolsong 2,3 and 4 to reduce the load on the vapour recovery driers and upgraders and the heavy water losses via the stack. There will also be improvements to monitor heavy water and tritium releases. This paper describes the improvements, gives background on heavy water balance mechanism, the historical trends for heavy water recovery/losses and estimated dose to the member of the public critical group resulting from the airborne and waterborne releases. The measured tritium activity levels in the heat transport system (HTS) and moderator system at Wolsong 1 are given. Using these activity levels and heavy water loss data, tritium losses from the dried and ventilated areas are estimated. A qualitative assessment of expected heavy water ...
1994-03-01
Utilization of geothermal energy in the USSR
International Nuclear Information System (INIS)
This paper reports that at present geothermal energy is utilized in the USSR mostly for district heating, and for industrial and agricultural purposes. The populations of 7 towns have district heating that is supplied by thermal waters. The population supplied totals about 125,000 people. The total area of greenhouses is 850,000 m"2. Electric energy generated at geothermal power stations still remains negligible with the installed capacity of the single Pauzhetka station (Kamchatka) being 11 MW. another station at Mutnovka is currently under construction and is expected to be producing 50 MW by 1992 and 200 MW by 1998. The proven geothermal resources in the USSR provide hope for a significant increase in the utilization of the earth's deep heat in the near future.
1990-08-20
Research on the preparation of coal water fuel (CWF) from Banko coal, south Sumatera
Energy Technology Data Exchange (ETDEWEB)
Studies of CWF preparation at laboratory scale have been carried out using the type and amount of additives and coal content as process variables. Other factors such as particle size, time and rate of stirring were kept constant. CWF with 45 wt% of dry solids, heating value of 5,475 BTU/lb, and stable without the evidence of sedimentation for 9 weeks have been obtained using carboxy methyl cellulose (CMC) as the additive. Low coal content and low heating value can be increased by hydrothermal process on the elevated temperature and pressure. By this process, CWF with dry solid of 55 wt% and a heating value of 7,125 BTU/lb could be obtained. 6 refs., 8 figs., 2 tabs.
1994-01-01
Precipitation mechanisms and subsequent hardening kinetics in the #beta#-CEZ alloy
International Nuclear Information System (INIS)
The #beta#-CEZ alloy : Ti-5%Al-2%Sn-4%Zr-4%Mo-2%Cr-1%Fe is a near #beta# titanium alloy. Since its processing routes include heat treatment (consisting of solution treatment and ageing), it has been decided to study the influence of the #beta# phase stability on #alpha# phase precipitation and hardening kinetics. Small sized specimens, coming from industrial heats, have been heat treated above and below the #beta# transus, and then water quenched. Therefore, several degree of #beta# stability are obtained. When it is increased (i.e. the solution treatment temperature is lowered), #alpha# or #omega# phases precipitations are delayed, as well as the hardening phenomena. Moreover, the #omega# stability domain is reduced. The mechanisms of #alpha# or #omega# precipitation are discussed, and related to the hardening kinetics. (orig.).
Clean combustion of solid fuels
International Nuclear Information System (INIS)
A chemical-looping process is proposed for the clean combustion of solid fuels for electric power or heat generation. The process is based on coal gasification with CO_2 to produce CO. The CO then reduces CaSO_4, which is used as an oxygen carrier, in a separate reactor to give CaS and CO_2. A portion of the CO_2 is recycled for the gasification stage and the rest can be sent for sequestration. The CaS is sent to another reactor for oxidation with air and to generate heat or power. The overall thermal effect is the same as direct combustion, but separation of CO_2 and other pollutants, such as sulphur, is achieved. In comparison with conventional chemical-looping combustion of natural gas, much less water is present in the CO_2 product, and hence the loss of heat energy and corrosion of the fuel-reactor system can be reduced.
2008-01-01
Causes of denting. Volume 1. Summary report. Final report
This summary report outlines the work that was performed to gain a more complete understanding of denting corrosion of steam generators in PWRs. Background laboratory and plant data on denting were compiled, reviewed and correlated to determine how various exposure conditions affect denting. Two high-temperature chemistry analytical models were reviewed and evaluated by experimental simulation of impurity concentration in the heat transfer and isothermal capsule tests. Simulation of impurity concentration for three cooling waters (lake, river, and cooling tower) was evaluated. The effects of species concentration (Cu/sup + +/, Cl/sup -/, O/sub 2/, and H/sup +/), contaminant thresholds (established by isothermal and heat transfer tests), and heat flux as indicated by superheat on denting were examined. A discussion of several pertinent observations and conclusions drawn from these tasks (as they pertain ...
1984-05-01
International Nuclear Information System (INIS)
Hydrogen (H) plasma treatment, oxygen (O) plasma treatment and water (H_2O)-vapor heat treatment for polycrystalline-silicon (poly-Si) thin-film transistors (TFTs) have been analyzed by separately extracting trap density at a front silicon-oxide interface (D_F) and trap density at a back interface (D_B). It is found that the H plasma treatment is apt to generate D_F and D_B. The O plasma treatment reduces D_F, while the H_2O-vapor heat treatment reduces both D_F and D_B. Improvement of transistor characteristics of poly-Si TFTs depends on understanding these results.
2004-05-17
Nuclear desalination for the petrochemical complex of the Natuna project
International Nuclear Information System (INIS)
On the basis of environmental considerations, a high temperature gas cooled reactor (HTGR) was proposed as the heat source for the Natuna project for CO_2 conversion. To convert CO_2 to useful products, a large amount of high quality water is required for the chemical processes, boilers and other purposes. One LNG production train (maximum of six trains) would produce 0.4 x 10"9 SCF/d of saleable gas and 1.4 x 10"9 SCF/d of CO_2 (in the case of the Exxon process). This CO_2 gas would then be converted to automobile fuel (methane, methanol), which requires a large amount of water. Natural gas from an off- shore gas field is piped to the petrochemical complex on Natuna Island (about 228 km). Natuna is a small island that, apart from sea water, does not have much available water. The desalination process is considered to be the only solution to the water demand ...
1997-12-01
Evaluating and improving the operating reliability of the units of sucker rod well pumps
Energy Technology Data Exchange (ETDEWEB)
The theory of reliability is used to develop statistical field data on malfunctions of units of sucker rod well pumps (UShSN). The indices of reliability of the UShSN are applied for establishment of the cause-effect links between the operating factors. Dependences of operating time on the depth of suspension of the pumps, mode of pumping out, degree of flooding of the oil, and twisting of the shafts are established for conditions of specific fields. The obtained relationships can be used in selecting and optimizing the work of the UShSN.
1982-01-01
International Nuclear Information System (INIS)
... bypasses control rod drives cylinders electromagnetic pumps fluid flow fluidic
Effect of a pumped storage plant on the generation reliability of the Taiwan power system
Energy Technology Data Exchange (ETDEWEB)
A novel approach to the reliability analysis of a power system with both hydro and pumped storage plants is presented in this paper. The proposed method is based on the concept of peak shaving for the hydro and pumped storage units. Different values of the stored energy of the pumped storage units are employed to demonstrate their effect on the generation reliability of a power system. The proposed scheme has been applied successfully to the reliability analysis of Taiwan power system.
1986-05-01
UNSAT-H Version 3.0: Unsaturated Soil Water and Heat Flow Model Theory, User Manual, and Examples
Energy Technology Data Exchange (ETDEWEB)
The UNSAT-H model was developed at Pacific Northwest National Laboratory (PNNL) to assess the water dynamics of arid sites and, in particular, estimate recharge fluxes for scenarios pertinent to waste disposal facilities. During the last 4 years, the UNSAT-H model received support from the Immobilized Waste Program (IWP) of the Hanford Site's River Protection Project. This program is designing and assessing the performance of on-site disposal facilities to receive radioactive wastes that are currently stored in single- and double-shell tanks at the Hanford Site (LMHC 1999). The IWP is interested in estimates of recharge rates for current conditions and long-term scenarios involving the vadose zone disposal of tank wastes. Simulation modeling with UNSAT-H is one of the methods being used to provide those estimates (e.g., Rockhold et al. 1995; Fayer et al. 1999). To achieve the above goals for assessing water dynamics and estimating ...
2000-06-12
Energy Technology Data Exchange (ETDEWEB)
Vaarst Vestervang (Denmark) comprises 16 villas and 1 communal building. The complex was designed by the inhabitants themselves with the aim of polluting the environment as little as possible. The land area constitutes 69.000 square meters where it is possible to grass animals. The document reports a measuring programme concerning the overall heat consumption as one of the main aims of the inhabitants is to save energy and thus contribute to the protection of the environment. The capacity of the solar collectors predominantly used in the building complex was 235 kWh/m{sup 2}. Supplementary heating is provided by boilers fired with wood. The measuring system is described in detail. Tables show the influence of heat transmission losses, ventilation, airing out of rooms, the angle of the sun`s rays within the buildings and heating needs on energy consumption. Energy consumption data is presented in ...
1993-10-01
Interface heat transfer of horizontal co-current liquid-liquid stratified flow. II - Entrance region
Flow structures and heat transfer at the liquid-liquid interface are investigated experimentally and analytically in the entrance region of a liquid metal-water stratified flow in a horizontal rectangular channel. The two-equation model and the mixing length mode, including a damping turbulent region near the interface, are used to obtain analytical results for pressure drop, position of the interface, and heat transmission coefficients across the interface. Analytical results are compared with experimental results. Conclusions are presented and include the following: (1) vertical position of the interface increases or decreases along the stream according to the fluid flow rate of both fluids, and then approaches a constant value in the fully developed region; (2) pressure drop increases along the stream from the minimum value at the inlet; and (3) heat transmission coefficients across the interface ...
1981-06-01
Energy Technology Data Exchange (ETDEWEB)
This paper describes the comprehensive modeling method of fluid and heat flows in the hydrological system. Based upon the concept that the hydrological system is composed of the air-water 2-phase fluids, and the rock phase, various natural processes are modeled including surface/subsurface 2-phase mass transfer, heat exchanges between fluid phases, between fluid and solid phases, and sensible/latent heat exchanges on the ground surface. A field-oriented numerical simulator is developed, in which a set of governing equations is solved for different variables on the surface and in subsurface regions, respectively. Results of an experimental study are presented, in which transient formulation of heat exchange between fluid/solid phases is examined through matching of the observation and calculated performances. (author)
1999-08-31
Energy Technology Data Exchange (ETDEWEB)
This paper describes the comprehensive modeling method of fluid and heat flows in the hydrological system. Based upon the concept that the hydrological system is composed of the air-water 2-phase fluids, and the rock phase, various natural processes are modeled including surface/subsurface 2-phase mass transfer, heat exchanges between fluid phases, between fluid and solid phases, and sensible/latent heat exchanges on the ground surface. A field-oriented numerical simulator is developed, in which a set of governing equations is solved for different variables on the surface and in subsurface regions, respectively. Results of an experimental study are presented, in which transient formulation of heat exchange between fluid/solid phases is examined through matching of the observation and calculated performances. (author)
1999-08-31
Drying characteristics and nitrogen loss of biogas digestate during drying process
Energy Technology Data Exchange (ETDEWEB)
The cost of transporting biogas digestate can be decreased by reducing its water content. However, the digestate emits volatile compounds during drying. This study investigated the drying behaviour and the change of digestate composition. Drying took place in a hybrid solar/waste-heat dryer that used solar energy as well as waste heat from a combined heat and power unit (CHP) and the exhaust air of a microturbine. The experiment involved the use of 60 t of liquid digestate. Climatic conditions were measured inside and outside the drying hall. Dry matter (DM) and organic dry matter (ODM) were also measured on a daily basis. In addition, the energy consumption of waste and solar heat were recorded and related to the quantity of dried feedstock. The total nitrogen, ammonium, phosphate, potassium oxide, magnesium oxide and calcium oxide in the digestate were subjected to chemical ...
2010-07-01
Augmentation of laminar flow and heat transfer in flat tubes by means of helical screw-tape inserts
Energy Technology Data Exchange (ETDEWEB)
The heat transfer a characteristics and friction factor in the horizontal double pipes of flat tubes with full length helical screw element of different twist ratio and helical screw inserts with different spacer length are investigated. Cold and hot water are used as working fluid in tube side and shell side respectively. The experiments covered a range of Reynolds numbers 5.7 x 10{sup 2} {<=} Re {<=} 1.31 x 10{sup 3}. The effect of spacer length on the heat transfer augmentation and friction factor and the effect of twist ratio on heat transfer augmentation and friction factor have been presented separately. The study shows that, the Nusslet number (Nu) and friction factor (f) decrease with the increase of S or Y for flat tube. The comparison between the data of present plain circular with that of previous plain circular tube showed a good agreement between them but the data of present ...
2011-01-15
Energy Technology Data Exchange (ETDEWEB)
In view of current trends in motor car development, the author investigates the increasing conflict between higher comfort and lower fuel consumption. The conflict results mainly from insufficient cooling water heating with consumption-optimized engines. So far, it was never necessary to analyze heat flow after cold starting and heat-up of the powertrain, to develop strategies for heat storage and distribution, to remove heat sinks and to use components multifunctionally. The contribution shows that a general heat management strategy for the whole vehicle will result in high potential fuel savings and improved thermal comfort. Using the example of a latent heat store, heating strategies for the engine and transmission system on the one hand and the passenger compartment on the other hand are ...
1999-07-01
Engineering design of cryocondensation pumps for the DIII-D Radiative Divertor Program
Energy Technology Data Exchange (ETDEWEB)
A new double-null, slotted divertor configuration will be installed for the DIII-D Radiative Divertor Program at General Atomics in late 1996. Four cryocondensation pumps, three new and one existing, will be part of this new divertor. The purpose of the pumps is to provide plasma density control and to limit the impurities entering the plasma core by providing pumping at each divertor strike point. The three new pumps are based on the design of the existing pump, installed in 1992 as part of the Advanced Divertor Program. The new pumps require geometry modifications to the original design. Therefore, extensive modal and dynamic analyses were performed to determine the behavior of these pumps and their helium and nitrogen feed lines during disruption events. Thermal and fluid analyses were also performed to characterize the helium two-phase ...
1995-10-01
Theoretical study on device efficiency of pulsed liquid jet pump
International Nuclear Information System (INIS)
The influence of the main factors on device efficiency of pulsed liquid jet pump with gas-liquid piston is analysed, the theoretical equation and its time-averaged solution of pulsed liquid jet pump device efficiency are derived. The theoretical and experimental results show that the efficiency of transmission of energy and mass to use pulsed jet is greatly raised, compared with steady jet, in the same device of liquid jet pump. The calculating results of time-averaged efficiency of pulsed liquid jet pump are approximately in agreement with the experimental results in our and foreign countries
2001-03-01
Pumped-storage hydropower schemes
Energy Technology Data Exchange (ETDEWEB)
The general types of pumped-storage plants and considerations for determining their need, use, and selection are presented. A brief discussion of TVA's experience on two pumped-storage schemes is included. Pumped-storage plants have become an integral part of many hydropower systems. Most of these systems use pumped-storage plants to meet power requirements during the peak load demands. In any application, large or small, the expected load demand and supply source must be identified to select the best scheme required for the particular system.
1984-01-01
Energy Technology Data Exchange (ETDEWEB)
This paper presents a new algorithm for the optimal long-range generation planning for a thermal system with pumped-storage plants. The algorithm is based upon the analytical production costing model developed under the assumption of Gaussian probabilistic distribution of random load fluctuations and plant outages. The optimization problem consists of the master problem to determine the annual investment, and the pumped-storage subproblem to determine the optimal pumped-storage operation. The master problem is formulated as a Hamiltonian minimization problem, and the pumped-storage subproblem is solved using the concept of peak-shaving operation on the original load curve.
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
This paper presents a new algorithm for the optimal long-range generation planning for a thermal system with pumped-storage plants. The algorithm is based upon the analytical production costing model developed under the assumption of Gaussian probabilistic distribution of random load fluctuations and plant outages. The optimization problem consists of the master problem to determine the annual investment, and the pumped-storage subproblem to determine the optimal pumped-storage operation. The master problem is formulated as a Hamiltonian minimization problem, and the pumped-storage subproblem is solved using the concept of peak-shaving operation on the original load curve.
1987-05-01
International Nuclear Information System (INIS)
The paper deals with the exploitation of the pumped storage plants for the control of the Slovak power system. For that purpose current utilization of pumped storage plants currently in operation was analyzed from the point of view of their part in the operation control of the Slovak power system. The aim of this analysis was to exploit knowledge gained so far for the future outlook up to the year 2010, including the evaluation of the need to construct pumped storage plant Ipel with a weekly storage cycle. (author).
1997-05-13
A study on diagnostic techniques of pump operating condition
Energy Technology Data Exchange (ETDEWEB)
The scope and contents investigate and reviewed are as follows : establishment of study plan and references survey, review of related problems and inservice test standards of safety injection pump in use nuclear power plant, review of the study results in laboratory, the theoretical investigation of temperature rise according to mini-flow rate of pump, mini-flow rate working characteristics of high and low pressure injection pumps at nuclear power plants, setup of testing equipment for measuring ampere, discharge pressure and vibration, selection and behaviors analysis of major parameters concerning pump degradation.
1998-03-15
Energy Technology Data Exchange (ETDEWEB)
Contamination and blockages of the cooling tubes in the turbine condenser disturb the heat transfer, thereby causing power losses at the turbine and increasing the fuel demand. Corrosions cause tubing leakages which require operating downtimes and reduce the lifetime of the pipes. Tube cleaning systems and backflushing cooling water filters eliminate these problems. Nevertheless it can come to coatings in the condenser tubes, if the tube cleaning equipment does not operate optimally or if coarse dirt is entered. Under this aspect, the author of the contribution under consideration reports on these problems on the basis of practical examples. The author gives references to the optimized operation of the tube cleaning system and the cooling water filtration.
2010-07-01
Energy Technology Data Exchange (ETDEWEB)
The liquid/vapor coexistence density, the partial vapor pressure, and the heat of vaporization were calculated using Gibbs ensemble Monte Carlo simulation techniques. Long-range interactions such as charge-charge, charge-dipole, and dipole-dipole were evaluated using Ewald summation techniques. A polarizable potential model was used to describe the water-water interactions (Dang and Chang, J. Chem. Phys. 106, 8149, 1997). The model yields good agreement with the corresponding experimental data in the lower temperature region and moderate agreement in the higher temperature region. The critical temperature and density were estimated to be 565 K and 0.28 g/cm3.
2001-12-01
Evaporation behavior of water and concentration of technetium and rhenium using thin film evaporator
International Nuclear Information System (INIS)
The nuclear energy cycle requires the recycling of nuclear fuel, water, chemical reagents, and the volume reduction of radioactive liquid wastes. A fundamental technique for continuous recovery of water using a thin-film evaporator was examined. Appropriate recovery measurements were: an evaporator heat temperature of 323 K, a feed rate of 0.23 cm"3 x s"-"1, a vacuum pressure of 15 mmHg (2 kPa), and impeller rotational speeds of 500#approx#600 rpm (min"-"1). The concentration of trace technetium and rhenium in aqueous solutions was also studied. A decontamination factor of 10"5 for rhenium was obtained. (author)
1999-06-01
Estimation of dry rubber content in natural rubber latex by differential scanning calorimetry
British Library Electronic Table of Contents (United Kingdom)
Differential Scanning Calorimetry (DSC) is employed to study the changes in enthalpy of natural rubber latex samples when heated under a controlled temperature program. It is found that the mass normalized areas of the DSC curves between room temperature and 170??C for different latex samples are inversely proportional to the dry rubber content (DRC) of the samples, measured following the weighing and drying method. The changes in total enthalpy of the samples in this temperature range are interpreted as due to the variations in the quantity of water present in the samples. The measurements have been repeated by diluting selected samples with known quantities of water, and it is found that the normalized areas of the DSC curves are directly proportional to the amount of water added to the ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
SKB is currently performing site investigations at two potential sites for a final repository for spent nuclear fuel. This report presents results of water flow and solute transport modelling of the Forsmark site. The modelling reported in this document focused on the near-surface groundwater, i.e. groundwater in Quaternary deposits and shallow rock, and surface water systems, and was performed using the MIKE SHE tool. The most recent site data used in the modelling were delivered in the Forsmark 2.3 dataset, which had its 'data freeze' on March 31, 2007. The present modelling is performed in support of the final version of the Forsmark site description that is produced during the site investigation phase. In this work, the hydrological modelling system MIKE SHE has been used to describe near-surface groundwater flow and the contact between groundwater and surface water at the Forsmark site. The surface ...
2008-09-15
Radiation-polymerizable mixture and recording material containing it
International Nuclear Information System (INIS)
Esters of dihydric alcohols with alkenylphosphonic or alkenylphosphinic acids which are polymerizable by free radicals are described. They are combined with polymer binders, in particular water-soluble polymers, and photoinitiators forming free radicals to give photopolymerizable mixtures which are suitable for the production of photoresists and printing plates. The mixtures display low heat-sensitivity and have long shelf lives. (author) 1 tab.
1991-01-01
Growth model and on-line measurement of pitting corrosion on carbon steel
Energy Technology Data Exchange (ETDEWEB)
A growth model of pitting corrosion of carbon steel in cooling water systems was developed on microscopic observations of pits and electrochemical studies. Results of pitting corrosion measurements in laboratory and field conditions with the model, using a newly developed electrochemical device, are discussed. For an actual heat exchanger up to a year operation, the values of pitting depth estimated were in good agreement with the measured values.
1996-12-01
Fundamental aspects of gas-liquid flows
Energy Technology Data Exchange (ETDEWEB)
This book presents the papers given at a conference on two-phase flow. Topics considered at the conference included the thermal hydraulics of a feedwater pipe breakage, pressure losses, measurement of void fraction in a rod bundle, laminar filmwise condensation, natural circulation, flow models, bubble dynamics, cavitation, water hammer, and heat transfer augmentation.
1985-01-01
Fundamental aspects of gas-liquid flows
International Nuclear Information System (INIS)
This book presents the papers given at a conference on two-phase flow. Topics considered at the conference included the thermal hydraulics of a feedwater pipe breakage, pressure losses, measurement of void fraction in a rod bundle, laminar filmwise condensation, natural circulation, flow models, bubble dynamics, cavitation, water hammer, and heat transfer augmentation.
1985-11-17
Energy Technology Data Exchange (ETDEWEB)
A research report describes the energy efficiency techniques to be employed in designing a building which is ``green``. Topics covered include building fabric performance, ventilation and infiltration, passive solar design, heating systems and controls, hot and cold water provision, lighting and electrical appliances. (UK)
1993-12-31
Capturing sun for car and house; Fanger sol til bil og hus
Energy Technology Data Exchange (ETDEWEB)
Solar panels have been installed at the roof, providing enough power to drive electric cars 20 000 kilometres yearly, while water-borne heating in the household has reduces electricity demand by 12-13 000 kWh per year
2008-07-01
Transient Critical Heat Flux tests on a rod bundle simulating Pressurized Water Reactors
International Nuclear Information System (INIS)
Transients induced in nuclear power plants from many sources result in one or more fluid conditions changing with time. Fluid conditions of pressure, inlet temperature, inlet flow, or even system power many change separately or in conjunction with each other. The result of the condition change may be one which induces departure from nucleate boiling. An experimental investigation of transient which were intended to achieve Critical Heat Flux was performed at the Heat Transfer Research Facility of Columbia University for Siemens Nuclear Power Corporation. The transients were set up to include broad ranges of flow and pressure conditions near the operating range of pressurized water reactors. Transient events were dominated by varying single conditions and measuring the response of the system and of the rod thermocouples. Because of coupling effects within the test loop, secondary conditions would also vary. In order to ...
Zero-G two phase flow regime modeling in adiabatic flow
Energy Technology Data Exchange (ETDEWEB)
Two-phase flow, thermal management systems are currently being considered as an alternative to conventional, single phase systems for future space missions because of their potential to reduce overall system mass, size, and pumping power requirements. Knowledge of flow regime transitions, heat transfer characteristics, and pressure drop correlations is necessary to design and develop two-phase systems. This work is concerned with microgravity, two-phase flow regime analysis. The data come from a recent sets of experiments. The experiments were funded by NASA Johnson Space Center (JSC) and conducted by NASA JSC with Texas A M University. The experiment was on loan to NASA JSC from Foster-Miller, Inc., who constructed it with funding from the Air Force Phillips Laboratory. The experiment used R12 as the working fluid. A Foster-Miller two phase pump was used to circulate the two phase mixture and allow separate measurements of ...
1993-01-15
Zero-G two phase flow regime modeling in adiabatic flow
International Nuclear Information System (INIS)
Two-phase flow, thermal management systems are currently being considered as an alternative to conventional, single phase systems for future space missions because of their potential to reduce overall system mass, size, and pumping power requirements. Knowledge of flow regime transitions, heat transfer characteristics, and pressure drop correlations is necessary to design and develop two-phase systems. This work is concerned with microgravity, two-phase flow regime analysis. The data come from a recent sets of experiments. The experiments were funded by NASA Johnson Space Center (JSC) and conducted by NASA JSC with Texas A ampersand M University. The experiment was on loan to NASA JSC from Foster-Miller, Inc., who constructed it with funding from the Air Force Phillips Laboratory. The experiment used R12 as the working fluid. A Foster-Miller two phase pump was used to circulate the two phase mixture and allow separate ...
1993-01-10
Solar energy conversions: solar-electric thermophotovoltaic systems and solar-powered gas lasers
Energy Technology Data Exchange (ETDEWEB)
This paper deals with conversions of solar energy efficiently into electricity and into gas laser radiation. In the first section, a review study of the possibility of a solar-electric thermophotovoltaic (TPV) device has been done. In a proposed extension of the TPV concept, a Cassagranian optical system concentrates solar radiation to heat a blackbody cavity to 2400/sup 0/K. A double-layer solar cell, GaAs and Si, forming the cylindrical surface concentric to the blackbody cavity, receives the blackbody radiation and converts it into electricity efficiently. A cell conversion efficiency of 50% or more would be possible with the TPV system. The second section explores the concept of blackbody radiation pumping of gas laser media as a step toward utilization of solar energy as a laser pumping source. To demonstrate this concept, an experiment was performed in which various gas mixtures of CO/sub 2/ and He were exposed to ...
1980-12-01
Data Center Energy Benchmarking: Part 3 - Case Study on an ITEquipment-testing Center (No. 20)
Energy Technology Data Exchange (ETDEWEB)
The data center in this study had a total floor area of 3,024 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 147 racks, and was located in a 96,000 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but was served by the main building chiller plant and make-up air system. Additionally it was served by only a single electrical supply with no provision for backup power in the event of a power outage. The Data Center operated on a 24 hour per day, year-round cycle, and users had full-hour access to the data center facility. The study found that data center computer load accounted for 15% of the overall building electrical load, while the total power consumption attributable to the data center including allocated cooling load and lighting was 22% of the total ...
2007-07-01
Energy Technology Data Exchange (ETDEWEB)
To help confirm correct functioning of an epithermal neutron sonde, we measured tightly bonded water content of selected Nevada Test Site (NTS) drill holes. Tuff and alluvium samples were dried overnight at 105/sup 0/C. The samples were then heated for 45 min in a split tube furnace at 700/sup 0/C. The water that came off due to this heating was collected and the amount recorded. The error in this procedure is +- 0.59 wt %. Total water can be calculated for samples from analyses of free and tightly bonded water contents. The maximum error in this calculation is equivalent to the error in determining the more tightly bonded water. Average total water content values have been assigned to geologic units. These values, in weight fraction, are alluvium 0.14 +- .05 and tuff 0.19 +- .04. Further division of the tuff gives ...
1981-05-01
Energy Technology Data Exchange (ETDEWEB)
Water power plants mean the design, configuration, execution and operation of buildings and of hydraulic and electrical machines. Their many types are due to the stages of development and the technical alternatives of the use of waterpower and the associated energy economy aspects. The main points of this work are the use of water power, different hydro-electric powerstations, water collection, machines and electrotechnical equipment. In the 2nd revised edition parts on electrical engineering, environment, minimum water run-off pumped storage plants, small scole plants, economical aspects and finite elements were broadened. It is a comprehensive textbook and technical book for students of civil engineering and particularly suitable for engineers active in the theory and practice of waterpower construction. (orig./GL) [Deutsch] Wasserkraftanlagen bedeuten Planung, Gestaltung, ...
1998-12-01
Energy Technology Data Exchange (ETDEWEB)
Water power plants mean the design, configuration, execution and operation of buildings and of hydraulic and electrical machines. Their many types are due to the stages of development and the technical alternatives of the use of waterpower and the associated energy economy aspects. The main points of this work are the use of water power, different hydro-electric powerstations, water collection, machines and electrotechnical equipment. In the 2nd revised edition parts on electrical engineering, environment, minimum water run-off pumped storage plants, small scole plants, economical aspects and finite elements were broadened. It is a comprehensive textbook and technical book for students of civil engineering and particularly suitable for engineers active in the theory and practice of waterpower construction. (orig./GL) [German] Dieses Standardwerk der Wasserkraft liegt hiermit bereits ...
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
The INCO ``INCOLOY 800`` trademark groups the Fe-Cr-Ni alloys containing 30 to 35% nickel, 19 to 23% chromium, 0,15 to 0,60% aluminium, 0,15 to 0,60% titanium and less than 0,10% carbon contents, used as construction materials for condenser and heat exchanger tubes. In parallel with water chemistry control and studies aimed at reducing the residual stresses resulting from tube expansion, studies have been conducted to a better understanding of this alloy, its metallurgy and its corrosion behaviour under accurately defined fabrication and heat treatment conditions. The purpose of this paper is to present the results of a behaviour study of INDRET alloy 800 concerning isothermal relaxation and effects of the said relaxation heat treatments on alloy microstructure studied with a transmission electron-chemical method to determine the sensitiveness to intergranular corrosion, and by electrochemistry in ...
1994-12-31
Pressure drop and heat transfer characteristics of boiling water in sub-hundred micron channel
Energy Technology Data Exchange (ETDEWEB)
The current work focuses on the pressure drop, heat transfer and stability in two phase flow in microchannels with hydraulic diameter of less than one hundred microns. Experiments were conducted in smooth microchannels of hydraulic diameter of 45, 65 {mu}m, and a rough microchannel of hydraulic diameter of 70 {mu}m, with deionised water as the working fluid. The local saturation pressure and temperature vary substantially over the length of the channel. In order to correctly predict the local saturation temperature and subsequently the heat transfer characteristics, numerical techniques have been used in conjunction with the conventional two phase pressure drop models. The Lockhart-Martinelli (liquid-laminar, vapour-laminar) model is found to predict the two phase pressure drop data within 20%. The instability in two phase flow is quantified; it is found that microchannels of smaller hydraulic diameter have lesser ...
2009-09-15
This work investigates the impingement of a liquid microdroplet onto a glass substrate at different temperatures. A finite-element model is applied to simulate the transient fluid dynamics and heat transfer during the process. Results for impingement under both isothermal and non-isothermal conditions are presented for four liquids: isopropanol, water, dielectric fluid (FC-72) and eutectic tin-lead solder (63Sn-37Pb). The objective of the work is to select liquids for a combined numerical and experimental study involving a high resolution, laser-based interfacial temperature measurement to measure interfacial heat transfer during microdroplet deposition. Applications include spray cooling, micro-manufacturing and coating processes, and electronics packaging. The initial droplet diameter and impact velocity are 80 {\\mu}m and 5 m/s, respectively. For isothermal impact, our simulations with water and ...
2010-01-01
International Nuclear Information System (INIS)
PWR plants have made efforts to maintain the long-term integrity of the steam generators (SG) by reducing the amount of corrosion products entering the secondary side of the SG. Iron entered the SG can cause several problems: degraded heat conductivity of the SG tubes in locations where iron is deposited, water level oscillations in the SG due to tube support plate hole blockage, and initiation and propagation of inter-granular attacks (IGA) and stress corrosion cracking (SCC). One of the most effective measures, high all-volatile treatment (AVT) chemistry has been applied to actual plants to reduce the flow-accelerated corrosion (FAC) coming from the carbon steel piping. The secondary water chemistry at Genkai NPS 1 and 2 changed, from the Low AVT chemistry to the High AVT chemistry, in November 2006. In this paper, we will describe the results of experiments in applying the use of High pH water in the ...
2009-02-01
Heat transfer augmentation by gas-particle two-phase flow
International Nuclear Information System (INIS)
The helium-cooled HTGR (High Temperature Gas-cooled Reactor) will take an important position in the global energy strategy. It is expected to supply not only electricity but also high quality thermal energy for various industries and local utilities without exhausting any green house effect gas or acid rain gas. The key R and D issue of the HTGR is economical competitiveness, particularly against light water reactors. Due to the poor heat transfer of the single phase helium, the HTGR's volumetric power density is restricted to tenth of corresponding PWR's value so that increasing the power density by improving heat transfer is strongly desired. The standstill can be broken through by adopting gas-solid suspension medium. Its heat transfer performance is quite excellent. Its heat capacity can be increased drastically without excessive pressurization. Although the thermal radiation is ...
1995-06-01
Energy Technology Data Exchange (ETDEWEB)
On behalf of the United Nations Environment Programme (UNEP) a study has been established by the Refrigeration, Air Conditioning and Heat Pump Technical Options Committee in which famous experts of refrigeration technology compiled facts which allow for a reliable prospect of real possibilities of changing from fluorine hydrogen to ozone innoxious substitutes and substitute technologies. With regard to the organization, a division into 6 committees for the establishment of the study has been made: 1. Refrigeration Options Committee, 2. Foams Options Committee, 3. Solvents, Coatings and Adhesives Options Committee, 4. Aerosols, Sterilants and Miscellaneous Uses Options Committee, 5. Halons Technical Options Committee and 6. Economic Options Committee. (BWI).
1992-09-01
Probabilistic fracture assessment of TAPP 3-4 PHT piping
International Nuclear Information System (INIS)
Methodology based on probabilistic fracture mechanics (PFM) is finding increasing acceptability in demonstrating safety of Nuclear Power Plant (NPP) piping. In PFM, the methods of fracture mechanics and reliability theory are combined for assessing the reliability of components, which contain cracks. In this work, reliability assessment of Tarapur Atomic Power Plant (TAPP) 3-4 Primary Heat Transport (PHT) piping is done using PFM. Monte Carlo simulation with stratified sampling is used as a variance reduction technique. PFM model assumes a pre-existing circumferential surface crack before the start of plant operation. The crack grows in size during the lifetime of the plant due to the fatigue loading. This part-through wall crack having escaped hydro-test and pre-service inspection, may result in either a through wall flaw (leak) or may lead to the rupture of the piping. R6 method is used as failure criteria. Steam generator inlet (SGI), steam generator outlet ...
2005-12-01
Potential of high-average-power solid state lasers
Energy Technology Data Exchange (ETDEWEB)
We discuss the possibility of extending solid state laser technology to high average power and of improving the efficiency of such lasers sufficiently to make them reasonable candidates for a number of demanding applications. A variety of new design concepts, materials, and techniques have emerged over the past decade that, collectively, suggest that the traditional technical limitations on power (a few hundred watts or less) and efficiency (less than 1%) can be removed. The core idea is configuring the laser medium in relatively thin, large-area plates, rather than using the traditional low-aspect-ratio rods or blocks. This presents a large surface area for cooling, and assures that deposited heat is relatively close to a cooled surface. It also minimizes the laser volume distorted by edge effects. The feasibility of such configurations is supported by recent developments in materials, fabrication processes, and optical pumps. Two types of ...
1984-09-25
Energy Technology Data Exchange (ETDEWEB)
Efficiency of energy coversion of primary energy to an end use in industrial countries is about 30%. This is insufficient. Evaluating on basis of exergy efficiency becomes only about 15%. Usage of fuel cells give a great chance to improve efficiency. This concerns in particular to high temperature fuel cell systems SOFC and MCFC as well as their combination with heat pumps. [German] Die Effizienz der Energieversorgung in Industrielaendern ist energetisch bewertet mit rund 30 % unbefriedigend. Legt man den strengeren, energiewirtschaftlich treffenderen exergetischen Massstab an, halbiert sich dieser Wert sogar. Brennstoffzellen bieten durch ihren Einsatz Moeglichkeiten zur Effizienzerhoehung. Dies gilt insbesondere fuer die Hochtemperatursysteme SOFC und MCFC sowie deren Verbund mit Waermepumpen.
2001-07-01
Extracting energy from hydraulically-fractured geothermal reservoirs
The governing equations for heat and mass transfer were derived for hydraulically fractured geothermal reservoirs. When converted to nondimensional form it was shown that the equations can be considerably simplified. The resulting equations can be strongly influenced by the effects of buoyancy; the magnitude of the effect is measured by the ratio of the Grashof and Reynolds numbers, and the ratio of the actual permeability of the fracture and the square of the fracture gap width. Significant quantities of energy can be extracted from hydraulic fractures--even without thermal stress fracturing. The amount is limited by the size of the fracture and the low thermal conductivity of rock. The viscous pressure drop in open fractures is insignificant, and depending upon losses in piping and surface equipment, the entire system could be ''self-pumped'' due to buoyancy. Thermal contraction of the rock tends to ...
1976-01-01
Determination of pressure distribution in an aerated bed in a controlled pilot-scale compost reactor
Energy Technology Data Exchange (ETDEWEB)
This study investigated the effectiveness of dealing with biological waste by composting. In particular, it examined the feasibility of recovering excess thermal energy produced in the process of composting biological waste in terms of mass and energy transport parameters required in the aerated compost bed. An experiment was performed in which a 100 dm{sup 3} adiabatic, leak-tight reactor equipped with a controlled aeration system was constructed to study the temperature and pressure distribution in the bed. Sensors were used to determine the amount and humidity of emitted gases under variable external physical conditions. The perforated bottom of the reactor allowed for bed aeration. As such, the humidity and heat were transported upwards, forced by the air pumped in and by natural convection. In terms of pressure distribution inside the composted and aerated bed, the study results showed that there were considerable differences in pressure ...
2010-07-01
Analysis and decision document in support of acquisition of steam supply for the Hanford 200 Area
Energy Technology Data Exchange (ETDEWEB)
The US Department of Energy (DOE) is now evaluating its facility requirements in support of its cleanup mission at Hanford. One of the early findings is that the 200-Area steam plants, constructed in 1943, will not meet future space heating and process needs. Because the 200 Area will serve as the primary area for waste treatment and long-term storage, a reliable steam supply is a critical element of Hanford operations. This Analysis and Decision Document (ADD) is a preliminary review of the steam supply options available to the DOE. The ADD contains a comprehensive evaluation of the two major acquisition options: line-term versus privatization. It addresses the life-cycle costs associated with each alternative, as well as factors such as contracting requirements and the impact of market, safety, security, and regulatory issues. Specifically, this ADD documents current and future steam requirements for the 200 Area, describes alternatives available to DOE for ...
1992-02-01
Water induction studies in a hydrogen-diesel dual-fuel engine
Energy Technology Data Exchange (ETDEWEB)
Power output of a hydrogen-diesel dual-fuel engine is limited by the onset of knock as the percentage of heat input derived from hydrogen increased beyond a certain limit. Earlier work carried out at the Internal Combustion Engines Laboratory, Indian Institute of Technology, Madras, indicates that this knock sets in when the induced hydrogen exceeds about 60% of input energy at a pilot diesel quantity of 30% of full load diesel amount. At higher rates of hydrogen induction, the richer hydrogen-air mixture is more prone to knocking. Hardly any information is available on the possibilities of improving the knock limited power output of a hydrogen-diesel dual-fuel engine. Water can serve as a powerful internal coolant in decreasing the unburned mixture temperature because of its high latent heat. This paper presents the results of our investigation on improving the knock limited power output when water is ...
1987-01-01
Operating PWR units in the USA have experienced very severe corrosion of the tube support plate at the crevice between the tube and the support. This results in distortion of the plate and crushing of the tube (denting). The first task of this project required that currently available computational methods to estimate the pH attained by concentrating boiler water under various fault conditions such as condenser leakage of river waters and faulty operation of condensate polishing plant. Particular attention has been paid to systems in which sulfate predominates. In the second task, the mechanisms are discussed by which solutions become concentrated in porous deposits on a boiling heat transfer surface. It is concluded that more experimental data are needed to test the validity of existing models. High solution concentrations in the deposit may occur at a heat flux close to the critical value for drying ...
1984-01-01
Mass transfer model for two-layer TBP oxidation reactions
Energy Technology Data Exchange (ETDEWEB)
To prove that two-layer, TBP-nitric acid mixtures can be safely stored in the canyon evaporators, it must be demonstrated that a runaway reaction between TBP and nitric acid will not occur. Previous bench-scale experiments showed that, at typical evaporator temperatures, this reaction is endothermic and therefore cannot run away, due to the loss of heat from evaporation of water in the organic layer. However, the reaction would be exothermic and could run away if the small amount of water in the organic layer evaporates before the nitric acid in this layer is consumed by the reaction. Provided that there is enough water in the aqueous layer, this would occur if the organic layer is sufficiently thick so that the rate of loss of water by evaporation exceeds the rate of replenishment due to mixing with the aqueous layer. This report presents measurements of mass transfer rates for the ...
1994-09-28
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
