WorldWideScience
1

Glass-heat-pipe evacuated-tube solar collector  

Science.gov (United States)

A glass heat pipe is adapted for use as a solar energy absorber in an evacuated tube solar collector and for transferring the absorbed solar energy to a working fluid medium or heat sink for storage or practical use. A capillary wick is formed of granular glass particles fused together by heat on the inside surface of the heat pipe with a water glass binder solution to enhance capillary drive distribution of the thermal transfer fluid in the heat pipe throughout the entire inside surface of the evaporator portion of the heat pipe. Selective coatings are used on the heat pipe surface to maximize solar absorption and minimize energy radiation, and the glass wick can alternatively be fabricated with granular particles of ...

1981-08-06

2

Pipe Freeze Prevention for Passive Solar Water Heaters Using a Room-Air Natural Convection Loop: Preprint  

Energy Technology Data Exchange (ETDEWEB)

Conference paper regarding research in the use of freeze prevention for passive solar domestic water heating systems.

2006-05-01

3

Northward Market Extension for Passive Solar Water Heaters by Using Pipe Freeze Protection with Freeze-Tolerant Piping: Preprint  

Energy Technology Data Exchange (ETDEWEB)

Conference paper regarding research in freeze-protection methods that could extend market acceptance for passive solar domestic water heating systems in more northern climates if the U.S.

2006-05-01

4

Equipment for a central heating system with expansion tank, pressure control, water loss supply, de-aeration, recording and control; Apparaat t.b.v. C.V.-installatie met expansievat, drukregeling, waterverliessuppletie, ontluchting, registratie en controle  

Energy Technology Data Exchange (ETDEWEB)

The very low-pressure expansion tank of the title invention is connected to the water in the central heating installation via a connecting pipe with a pump and valves on one side, and on the other side the tank is connected via a connecting pipe with valve to the tap water mains, so that the supply of water can be regulated automatically. Within the expansion tank contact with the outside air is not possible because of an air/water separating floater. By means of recording and control (also remote) of the contents of the expansion tank, the installation pressure and the quantity of supplied water from the expansion tank and the tap water mains, failures and water damage are prevented. 4 figs.

1995-09-01

5

Pipe-to-pipe impact program  

Energy Technology Data Exchange (ETDEWEB)

The objective of this research was to determine the extent of damage that occurs when two pipes experience an impact event due to one whipping against the other. The research was conducted through experimental and analytical approaches. The former required the development of a specialized impact machine that could accelerate a whipping pipe with sufficient energy to cause failure of a target pipe that was heated and pressurized to Pressurized Water Reactor (PWR) conditions. Damage was measured in terms of crushing, bending, and failure. The results of the tests permitted the correlation between pipes of a certain size and the damage they could cause when impacting with a certain amount of known energy. These results were used to evaluate the pipe whip criteria in the Standard Review Plan 3.6.2-4. It was established that the criteria ...

1987-05-01

6

Leak-before-break strategy for CANDU primary piping systems  

Energy Technology Data Exchange (ETDEWEB)

Recent advances in elastic-plastic fracture mechanics have made it possible to assess the stability of cracks in ductile piping systems. These technological developments have been used by Ontario Hydro as the nucleus of an approach for demonstrating that CANDU primary heat transport piping systems will not break catastrophically; at worst they would leak at a detectable rate. This leak-before-break approach has been taken on the Darlington nuclear generating station as a design stage alternative to the provision of pipe whip restraints on large diameter, primary heat transport system piping. Positive conclusions reached via this approach are considered sufficient to exclude the requirement to provide protective devices, such as pipe whip restraints. In arriving at the proposed leak-before-break approach a review of current and proposed ...

1986-01-01

7

A study on convective heat transfer with microcapsulated lauric acid slurry in circular pipe  

Energy Technology Data Exchange (ETDEWEB)

The objective of the present study is to reveal thermal characteristic of microcapsulated lauric acid slurry in circular pipe. Test were performed with microcapsulated lauric acid slurry in a heating test section with a constant heat flux boundary condition. Local Nusselt number and the effective thermal capacity were measured. As the size of microcapsulated lauric acid were increased, local Nusselt number of microcapsulated lauric acid slurry were increased. The effective thermal capacity of microcapsulated lauric acid slurry was 0.5 times than it of water.

2003-07-01

8

Binary heat pump system. Binary heat pump system  

Energy Technology Data Exchange (ETDEWEB)

This technical report describes an outline, features, total energy efficiency, and specifications of binary heat pump system. A closed circuit distributed water heat source heat pump method is employed in the binary heat pump system. Since the circulating water, which is adjusted at a constant temperature, is used as the heat source of the indoor unit, a stable performance can be obtained regardless of outside atmospheric temperature. The binary heat pump system is mainly composed of a center heat pump unit, indoor heat pump unit, heat source water pipes, and circulating pump. The center heat pump unit and the indoor heat pump unit are connected with each other by the ...

1993-11-30

9

Potential gas entry into FFTF after a postulated pipe rupture  

International Nuclear Information System (INIS)

... failures fftf reactor heat transfer hydraulics loss of coolant pipes primary coolant

10

Flow Regime Map Models for the Horizontal and Vertical Pipes for the SPACE code  

Energy Technology Data Exchange (ETDEWEB)

A safety analysis code, named as SPACE, for a pressurized water reactor is under development to obtain a licensing to be used for the PWR design and to hold entire proprietary rights. The task of KAERI is to develop the physical models and correlations which are required to solve the field equations. It can be divided into four parts; i) flow regime determination, ii) wall heat transfer, iii) wall and interfacial friction, iv) interfacial heat and mass transfer. This paper will describe the process to develop the models for the two-phase flow regime maps in the horizontal and vertical pipes.

2008-05-15

11

Flow Regime Map Models for the Horizontal and Vertical Pipes for the SPACE code  

International Nuclear Information System (INIS)

A safety analysis code, named as SPACE, for a pressurized water reactor is under development to obtain a licensing to be used for the PWR design and to hold entire proprietary rights. The task of KAERI is to develop the physical models and correlations which are required to solve the field equations. It can be divided into four parts; i) flow regime determination, ii) wall heat transfer, iii) wall and interfacial friction, iv) interfacial heat and mass transfer. This paper will describe the process to develop the models for the two-phase flow regime maps in the horizontal and vertical pipes.

2008-05-01

12

Emergency core cooling device for a reactor  

International Nuclear Information System (INIS)

Purpose : To obtain an emergency core cooling device in a FBR type reactor by utilizing heat pipes which are not actuated at usual operation condition but actuated reliably upon emergency. Constitution : A system for injecting heat medium into heat pipes is provided. By injecting the heat medium into the heat pipes upon emergency to actuate the heat pipes, the reactor core is cooled. During normal reactor operation, the inside of the heat pipes is evacuated from a vacuum pump and no heat medium is filled therein, whereby unnecessary heat loss during the normal operation can be prevented. (Ikeda, J.).

1982-01-24

13

Isolation condenser passive cooling of a nuclear reactor containment  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a nuclear system comprising a containment airspace in which a nuclear reactor pressure vessel is disposed there being a reactor core within the pressure vessel. It comprises a heat exchanger elevated a distance above the pressure vessel; a pool of water surrounding the heat exchanger; means for venting the pool of water to an environment outside the containment; a heat exchanger entry conduit within the containment, the entry conduit having an open lower end communicating with the containment space, and an upper end connected to the heat exchanger, water-containing heated fluid present in the containment airspace incident a pressure vessel loss of coolant event entering and flowing through the entry conduit into the heat exchanger for cooling the fluid to convert ...

1991-10-22

14

Performance of a commercial heat pipe under operational conditions  

Energy Technology Data Exchange (ETDEWEB)

The performance of a commercial heat pipe was investigated both experimentally and theoretically. The effect of the temperature difference, the surface area ratio, and the operational conditions on the performance were studied. The heat flow rate and the vapor temperature were estimated on a ready-made commercial heat pipe. Its performance varied considerably with operational conditions. Theoretical consideration of a mathematical model and several nomographs are also presented. This work is applicable to the design and use of heat pipes in the field.

1983-04-01

17

Device for the inspection of curved pipes in steam raising units  

Energy Technology Data Exchange (ETDEWEB)

The chain of eddy current probes and a film cassette probe, which responds to radiation from a radio-active source in one of the heat exchanger pipes is examined. The probes are moved by nylon pipes on both ends of the chain through the pipe to be examined. The nylon pipes are bent off load. In this way the probes on the chain will adjust near to the plane of bending of the pipes to be tested.

1980-01-03

18

Analysis of cost-effective pipe insulation requirements  

Energy Technology Data Exchange (ETDEWEB)

The proposed ASHRAE/IES Standard 90.1-1989R contains updated requirements for pipe insulation thicknesses developed on the basis of technical and economic principles. These requirements were determined based on computer simulations of the annual energy loss through the insulation, first cost assumptions for the insulation, and economic assumptions of discount rate and energy escalation rate. In later work, the same tools were used to analyze the sensitivity of the cost-effective insulation level for piping insulation to variations in operating hours, ambient temperature, fluid temperature, and economic assumptions. These analyses were carried out using cost data for pipe insulation averaged across several sources. The results of the sensitivity study showed that system operating hours is a critical parameter in determining the cost-effective pipe insulation thicknesses. Although there is a lack of ...

1997-09-01

19

Design and operation of an apparatus for calorimetric emittance measurements of pipe surfaces  

Energy Technology Data Exchange (ETDEWEB)

A technique for the measurement of the total hemispherical emittance of pipe surfaces is described, and design and operational details are given. The technique is conceptually simple. A long test pipe (e.g., 3.4 m) is mounted concentrically inside a Pyrex glass pipe. The system is evacuated, and the test pipe is heated by means of an electrical resistance heater. Heat transfer from the test pipe to the enclosure is almost solely radiative, allowing an average emittance for the test pipe and the Pyrex pipe and the electrical power input to the heater. By varying the electrical power level, one can measure the test pipe emittance as a function of temperature. By using a simple correction to account for the finite length of the test pipe, one can calculate the ...

1981-10-01

20

Overview of reliability test program on primary coolant piping of light water reactors  

Energy Technology Data Exchange (ETDEWEB)

Upon request by the Science and Technology Agency of Japanese Government, the Japan Atomic Energy Research Institute has conducted Piping Reliability Test Program to demonstrate the safety and reliability of light water reactor primary pipings. In this report, the results of the program are summarized. In the test program, pipe fatigue tests, Leak-Before-Break (LBB) verification tests and pipe rupture tests were carried out to examine the integrity of pipings, to verify the LBB concept and to demonstrate the effectiveness of the protective measures against jet impingement and pipe whip under pipe rupture event, respectively. In the pipe fatigue tests, a procedure to predict the fatigue crack growth was developed and the integrity of piping during plant service life was ...

1993-10-01

21

Heat pipe cooled piston - feasibility study  

Energy Technology Data Exchange (ETDEWEB)

This study assesses the feasibility of the so-called heat pipe technique for cooling the piston of a mediumspeed diesel engine and is part of a research project 'EVE HPD, Extreme Value Engine Tests with High Power Density' carried out by HUT Internal Combustion Engine Laboratory. Diesel engines are being developed to give greater power from a given cylinder swept volume, which means higher temperatures in combustion chamber. The traditional oil cooling cannot be used beyond certain temperature level. Heat pipe technology could provide one solution to the cooling problem. The general properties, principles of operation, and structures of different types of heat pipes are described. Working fluids and container materials of heat pipes are discussed. The operation limitations of heat ...

2004-07-01

22

Fundamental aspects of gas-liquid flows  

Energy Technology Data Exchange (ETDEWEB)

This book presents the papers given at a conference on two-phase flow. Topics considered at the conference included the thermal hydraulics of a feedwater pipe breakage, pressure losses, measurement of void fraction in a rod bundle, laminar filmwise condensation, natural circulation, flow models, bubble dynamics, cavitation, water hammer, and heat transfer augmentation.

1985-01-01

23

Fundamental aspects of gas-liquid flows  

International Nuclear Information System (INIS)

This book presents the papers given at a conference on two-phase flow. Topics considered at the conference included the thermal hydraulics of a feedwater pipe breakage, pressure losses, measurement of void fraction in a rod bundle, laminar filmwise condensation, natural circulation, flow models, bubble dynamics, cavitation, water hammer, and heat transfer augmentation.

1985-11-17

24

Study of a loop heat pipe using neutron radiography.  

Science.gov (United States)

An explanation is given of what a loop heat pipe (LHP) is, and how it works. It is then shown that neutron imaging (both real time neutron radioscopy and single exposure neutron radiography) is an effective experimental tool for the study of LHPs. Specifically, neutron imaging has helped to identify and correct a cooling water distribution problem in the condenser, and has enabled visualization of two-phase flow (liquid and vapor) in various components of the LHP. In addition, partial wick dry-out, a phenomenon of great importance in the effective operation of LHPs, is potentially identifiable with neutron imaging. It is anticipated that neutron radioscopy and radiography will greatly contribute to our understanding of LHP operation, and will lead to improvement of LHP modeling and design. PMID:15246420

2004-10-01

25

Study of a loop heat pipe using neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

An explanation is given of what a loop heat pipe (LHP) is, and how it works. It is then shown that neutron imaging (both real time neutron radioscopy and single exposure neutron radiography) is an effective experimental tool for the study of LHPs. Specifically, neutron imaging has helped to identify and correct a cooling water distribution problem in the condenser, and has enabled visualization of two-phase flow (liquid and vapor) in various components of the LHP. In addition, partial wick dry-out, a phenomenon of great importance in the effective operation of LHPs, is potentially identifiable with neutron imaging. It is anticipated that neutron radioscopy and radiography will greatly contribute to our understanding of LHP operation, and will lead to improvement of LHP modeling and design.

2004-10-01

26

Study of a Loop Heat Pipe Using Neutron Radiography  

Energy Technology Data Exchange (ETDEWEB)

An explanation is given of what a loop heat pipe (LHP) is, and how it works. It is then shown that neutron imaging (both real time neutron radioscopy and single exposure neutron radiography) is an effective experimental tool for the study of LHPs. Specifically, neutron imaging has helped to identify and correct a cooling water distribution problem in the condenser, and has enabled visualization of two-phase flow (liquid and vapor) in various components of the LHP. In addition, partial wick dry-out, a phenomenon of great importance in the effective operation of LHPs, has been identified with neutron imaging. It is anticipated that neutron radioscopy and radiography will greatly contribute to our understanding of LHP operation, and will lead to improvement of LHP modeling and design.

2001-08-01

27

Results of reliability test program on light water reactor piping  

Energy Technology Data Exchange (ETDEWEB)

The Japan Atomic Energy Research Institute has conducted a piping reliability test program to demonstrate the safety and reliability of light water reactor primary piping. In this program, pipe fatigue test, leak-before-break (LBB) verification test and pipe rupture test were carried out to examine the integrity of piping, to verify the LBB and to demonstrate the effectiveness of protective measures against jet impingement and pipe whip loads under a pipe rupture event.In the pipe fatigue test, a procedure to predict the fatigue crack growth was developed, and the integrity of piping during the plant service life was evaluated. In the LBB verification test, the pipe fracture test and the leak rate test were performed to verify the LBB in the primary ...

1994-12-01

28

Microbiologically influenced corrosion of carbon and stainless steel pipes; Mikrobiologisch beeinflusste Korrosion an Rohrleitungen aus unlegierten und hochlegierten nichtrostenden Staehlen  

Energy Technology Data Exchange (ETDEWEB)

About ten years ago microbiologically influenced corrosion manifested on stainless steel pipes used with river water for cooling a chemical plant. The pipe material was similar to Type 316 L. After only six weeks of operation pinhole leaks occurred nearly simultaneously at several welded joints of the pipe. The material degradation was simulated in laboratory and field corrosion tests. Microbiologically influenced corrosion failures also appeared on the pipes of a tubular heat exchanger of duplex steel Type 31803 and on carbon and stainless steel pipes in industrial waste water purification plants after these plants had been modernized with a biological purification unit. The basics of microbiologically influenced corrosion phenomena and typical corrosion failures of pipes will be described. (orig.) ...

1999-09-01

29

Wax and hydrate control with electrical power  

Energy Technology Data Exchange (ETDEWEB)

Electrical heating of subsea flowlines is an effective way to prevent wax and hydrate information, especially for long transportation distances and in low-temperature deep water. Systems are available for use in conjunction with bundles, pipe-in-pipe, and wet-thermal-insulation systems. These systems provide environmentally friendly fluid-temperature control without chemicals or flaring for pipeline depressurizing. Enhanced production is achieved because no time is lost by unnecessary depressurizing, pigging, heating-medium circulation, or removal of hydrate and wax blockages. The seabed temperature at 100-m and greater water depths may range from 7 to {minus}1.5 C, causing a rapid cooling of the hot well streams being transported in subsea flowlines. Under these supercooling conditions, vulnerable crude oils and multiphase compositions will deposit wax and asphalts; also the ...

1997-08-01

30

Advances in enhanced heat transfer: 1987  

Energy Technology Data Exchange (ETDEWEB)

This book contains nine selections. Some of the titles are: High Heat-Flux, Forced-Convection Heat Transfer for Tubes with Twisted-Tape Inserts; Heat Transfer Augmentation by Interrupted Surfaces - Experimental Consideration; Turbulent Flow Heat Transfer from Externally Roughened Tubes in Axial Flow in Concentric Pipe Heat Exchangers; and Heat Transfer Enhancement of Turbulent Flow in Pipes with an Internal Circular Rib.

1987-01-01

31

Advances in enhanced heat transfer: 1987  

International Nuclear Information System (INIS)

This book contains nine selections. Some of the titles are: High Heat-Flux, Forced-Convection Heat Transfer for Tubes with Twisted-Tape Inserts; Heat Transfer Augmentation by Interrupted Surfaces - Experimental Consideration; Turbulent Flow Heat Transfer from Externally Roughened Tubes in Axial Flow in Concentric Pipe Heat Exchangers; and Heat Transfer Enhancement of Turbulent Flow in Pipes with an Internal Circular Rib.

1987-08-09

32

Augmentation of laminar flow and heat transfer in flat tubes by means of helical screw-tape inserts  

British Library Electronic Table of Contents (United Kingdom)

The heat transfer a characteristics and friction factor in the horizontal double pipes of flat tubes with full length helical screw element of different twist ratio and helical screw inserts with different spacer length are investigated. Cold and hot water are used as working fluid in tube side and shell side respectively. The experiments covered a range of Reynolds numbers 5.7x102Re1.31x103. The effect of spacer length on the heat transfer augmentation and friction factor and the effect of twist ratio on heat transfer augmentation and friction factor have been presented separately. The study shows that, the Nusslet number (Nu) and friction factor (f) decrease with the increase of S or Y for flat tube. The comparison between the data of present plain circular with that of previous plain ci...

2011-01-01

33

Pipe whip experiments involving impacts between pipes  

International Nuclear Information System (INIS)

Dynamic pipe impact tests were performed in order to determine the impact conditions for which a 2 inch Schedule 80 carbon steel target pipe would not be broken if it were impacted during a pipe whip event created by a postulated break of an adjacent larger parallel pipe. Such pipe/pipe impact scenarios are of special interest for the feeder pipes of a CANDU reactor because the large number of closely spaced parallel feeder pipes that carry coolant between large primary system pipes and individual fuel channels in the reactor core makes it impractical to consider providing feeder pipe whip restraints. The testing which was performed involved simulating the behaviour of 3 inch and larger whipping pipes in order to study their impact with 2 inch target pipes ...

34

Demonstration of piping integrity with SMA technology  

Energy Technology Data Exchange (ETDEWEB)

The safe function of a new pipe whip restraint device has been demonstrated in a full scale test. The restraint is based on using a shape memory alloy to protect a pipe and its environment in the event of a double-ended-guillotine-break. The evaluation test has been performed at boiling water reactor (BWR) operating pressure and temperature using a pipe representing BWR primary piping. (orig.) 2 refs.

1997-10-01

35

Low temperature humidification dehumidification desalination process  

Energy Technology Data Exchange (ETDEWEB)

The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling ...

2006-03-01

36

Low temperature humidification dehumidification desalination process  

International Nuclear Information System (INIS)

The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling ...

2006-03-01

37

Study for developing method of repairing interior of duct. Kanro naimen hoshu koho no kaihatsu kenkyu  

Energy Technology Data Exchange (ETDEWEB)

A hose lining process, used widely for underground service structures, such as for city gas, and water and sewerage pipes, was adopted to repair interiors of underground wire raceways, and improvements were made for power cable pipe use, including long size construction, inner diameter assurance, and flame retardation. The sealing hose as a lining material consists of a fabric layer woven by warps of polybutylene terephthalate (PBT) and wefts of combined PBT fibers and glassfibers, the fabric being coated with polyurethane resin on one side. The other side of the fabric is coated with heat hardening resin made of epoxy resin as the main ingredient and aromatic amine as the hardening agent to assure close adhesion of the sealing hose onto the pipe interior. Mimic raceways were used to verify the lining material for its abrasion coefficient, mechanical strength, wear resistance, ...

1991-03-25

38

Phytoplankton primary production in a eutrophic cooling water pond  

Energy Technology Data Exchange (ETDEWEB)

The effect of longer ice-free periods on the seasonal variation and total annual values of phytoplankton primary production was considered along with the efficiency and productivity of the phytoplankton communities at different water temperatures by constant light. The studied pond, Vasikkalampi, is located in the town Jvyaskyla in central Finland. The pond is slightly eutrophic and its water is used for cooling purposes by a 35 MW thermal powerplant. The cooling water is taken in the middle of the pond and it returns as heated effluent to the northern part, near the surface, about 100 m from the intake pipe. This circulation and warming of the water keeps the pond open throughout the year except during the coldest weeks in the winter when some parts freeze over. The increase of the water temperature was not sufficient to be optimal for ...

1984-01-01

39

Flooding characteristics of gas-liquid two-phase flow in a horizontal U bend pipe  

International Nuclear Information System (INIS)

To evaluate safety of horizontal steam generator used in passive safety system, it is needed to make clear flooding characteristics in U bend pipe. In this study, two-phase flow experiment in a horizontal U bend pipe was carried out to make clear the influence of the length of horizontal pipe and the radius of U bend. Flooding in the U bend pipe was observed in the condition of lower gas or liquid volumetric flux than that in the horizontal pipe or the vertical pipe. Flooding and carry-up in the U bend pipe is hardly change with increasing the length between the water inlet and the U bend, but greatly related with the length from the water inlet to the lower tank and the shape of the U bend inlet. (author).

1994-05-01

40

Heat pipes and two-phase loops with capillary pumping; Caloducs et boucles diphasiques a pompage capillaire  

Energy Technology Data Exchange (ETDEWEB)

This workshop on heat pipes and two-phase capillary pumping loops was organized by the French society of thermal engineers. The 11 papers presented during this workshop deal with the study of thermal performances of heat pipes and on their applications in power electronics (cooling of components), and their use in satellites, aircrafts and trains. (J.S.)

1996-12-31

41

High thermal load receiving heat plate  

Energy Technology Data Exchange (ETDEWEB)

The present invention concerns a high thermal load heat receiving plate such as a divertor plate of a thermonuclear device. The high thermal load heat receiving plate of the present invention has a cooling performance capable of suppressing the temperature of an armour tile to less than a threshold value of the material against high thermal loads applied from plasmas. Spiral polygonal pipes are inserted in cooling pipes at a portion receiving high thermal loads in the high temperature load heat receiving plate of the present invention. Both ends of the polygonal pipes are sealed by lids. An area of the flow channel in the cooling pipes is thus reduced. Heat conductivity on the cooling surface of the cooling pipes is increased in the high thermal load heat receiving plate having ...

1993-09-28

42

Dalia integrated production bundle (IPB): an innovative riser solution for deep water fields  

Energy Technology Data Exchange (ETDEWEB)

The Dalia field is located 210 km north west of Luanda (Angola), about 140 km from shore in 1400 meter water-depth. It was the second major discovery out of 15 made in the block 17 operated by Total. The Dalia Umbilical, Flow lines and Risers EPCI Contract was awarded in 2003. The sea-line network to connect and control the 71 wells and 9 manifolds consist of the following: 40 km of insulated pipe in pipe (12 inches into 17 inches) production flow lines; 45 km of 12 inches water and gas injection lines; 6 off 1.7 km flexible water and gas injection risers; 8 off 1.65 km flexible Integrated Production Bundle (IPB) risers; 75 km of control umbilicals. The flow assurance and associated insulation requirement of the production transport system was one of the main challenges of the project. With a crude temperature of 45 deg C at the wellhead and the required minimum temperature of 35 ...

2008-07-01

43

Pipe whip studies  

Energy Technology Data Exchange (ETDEWEB)

An experimental and analytical study was performed to improve understanding of the dynamic impact behavior of carbon steel pipes. The test program addressed two types of pipe impact scenarios using both 2- and 4-in. Sch-80 pipes and elbows. Projectile-on-pipe tests simulated the behavior of a stationary target pipe which is impacted at its center by a larger, more rigid whipping pipe. These target pipes, which contained non-flowing water at about 290{degree}C temperature and ca 8.5 megapascals pressure, exhibited a peak deformation of up to 45% reduction in their diameter. For each test condition, the local deformation at the impact zone is a function of the peak impact force and impact velocity. Pipe-on-wall tests simulated the impact of an elbow at the free end of a cantilevered whipping ...

1984-06-01

44

Long-term storage of solar heat  

Energy Technology Data Exchange (ETDEWEB)

Stochastic models for the simulation of global radiation are discussed. Thermal transients in the ground are analyzed. The performance of buried-pipe storage and a space heating system with long-term storage is described.

1981-06-01

45

DEPLOYABLE HEAT PDPE RADUATOR - NASA Technical Report Server (NTRS)  

Science.gov (United States)

Eninger, J. E.: "Menisci Coalesence as a Mechanism for Venting Noncondensible. Gas From Heat-Pipe Arteries", AIAA Paper No. 74-748. ...

46

Augmentation of radiative heat transfer in an infinite cylindrical pipe enclosing a participating gas  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to identify the radiative heat transfer augmentation by a coaxial cylinder introduced in the infinite cylindrical pipe enclosing a participating gas. The gas is either a mixture of water vapor and carbon dioxide or gray. The gas is assumed to be homogeneous at a constant temperature, and has a refractive index of unity. All of the surfaces are opaque and gray, diffusely emitting and reflecting at a constant temperature. The effect of system diameter, diameter ratio, wall emittances, gas and surface temperatures, mixture component on heat transfer augmentation are studied by using the zone method with participating gas radiative properties evaluated from the weighted sum of gray gases model. From the radiative equilibrium condition, the installed wall temperature is formulated and calculated by the iteration method. If the medium is a gray gas, the augmentation observed are ...

1992-10-01

47

Fiscal 2000 project of inviting proposals for international joint research - invitation for international proposal (Energy conservation No.2). Achievement report on international joint study on popularization promotion of geothermal heat pump-assisted environmentally compatible heating system for Changchun City, China; 2000 nendo kokusai kyodo kenkyu teian kobo jigyo - kokusai teian kobo (Shoe No.2). Chinetsu heat pump ni yoru Chugoku Changchun shi kankyo tekigogata danbo system no fukyu sokushin ni kansuru kokusai kyodo kenkyu seika hokokusho  

Energy Technology Data Exchange (ETDEWEB)

A geothermal heat pump-assisted heating system is introduced into Changchun City and a survey is conducted to determine if the system may be popularized in this extremely cold region located in the northeastern part of China. In concrete terms, the hot water that circulates through the office building of Changchun Ground Heat Development Co., Ltd., is switched to hot water prepared by a geothermal heat pump. The test continued from December 2000 to March 2001. It is then concluded that heating by geothermal heat pumps will be fully serviceable to Changchun City. Implemented are (1) the shift from the coal fired boiler system to a geothermal heat pump system comprising 16 subterranean heat exchangers for the heating of the office building which is ...

2001-03-01

48

Improvement in efficiency and savings potentials at the ''cold end'' by means of tube cleaning and cooling water filtration; Wirkungsgradverbesserung und Einsparpotentiale am ''kalten Ende'' durch Rohrreinigung und Kuehlwasserfiltration  

Energy Technology Data Exchange (ETDEWEB)

Contamination and blockages of the cooling tubes in the turbine condenser disturb the heat transfer, thereby causing power losses at the turbine and increasing the fuel demand. Corrosions cause tubing leakages which require operating downtimes and reduce the lifetime of the pipes. Tube cleaning systems and backflushing cooling water filters eliminate these problems. Nevertheless it can come to coatings in the condenser tubes, if the tube cleaning equipment does not operate optimally or if coarse dirt is entered. Under this aspect, the author of the contribution under consideration reports on these problems on the basis of practical examples. The author gives references to the optimized operation of the tube cleaning system and the cooling water filtration.

2010-07-01

49

Emergency core cooling system  

International Nuclear Information System (INIS)

Purpose: To obtain stabilized operation by preventing over heat in emergency cooling pumps upon accidents of flow regulators. Constitution: A pressure suppression chamber pool and a pressure vessel are communicated to each other with a pipeway and the water in the suppression pool is charged by a charging pump to the pipeway. The pipeway is interposed with an emergency cooling pump so as to feed water in the pipeway to the pressure vessel and a water source and the emergency cooling pumps are connected by way of a closed pipeway. Further, the closed pipeway and the pipeway interposed with the charging pump are communicated to each other by way of a connecting pipeway, to which are interposed an instrument for detecting the increase in the temperature of the emergency cooling pumps due to abnormality in the closed pipe (such as troubles in flow regulators) and outputting control ...

50

Corrosion failure and its prevention in light water reactor power plants  

Energy Technology Data Exchange (ETDEWEB)

During 17 years since the start of operation of the first commercial LWR in Japan, many LWRs have experienced various corrosion damages, but the causes of them were clarified, and the counter-measures were executed effectively in actual plants, as the results, the cause of corrosion damage decreased remarkably, and now, the high rate of operation has become to be maintained. In this paper, the major cases of corrosion damage experienced in LWRs in Japan and foreign countries, the causes of them and the countermeasures, the problems of hereafter and so on are described. The corrosion damage of metallic materials in the environment of LWRs occurs in the parts in contact with high temperature, high pressure water and steam, such as stainless steel piping in the primary cooling system of BWRs, and nickel alloy heating tubes of steam generators, carbon steel feed water piping and ...

1988-01-01

51

Corrosion failure and its prevention in light water reactor power plants  

International Nuclear Information System (INIS)

During 17 years since the start of operation of the first commercial LWR in Japan, many LWRs have experienced various corrosion damages, but the causes of them were clarified, and the counter-measures were executed effectively in actual plants, as the results, the cause of corrosion damage decreased remarkably, and now, the high rate of operation has become to be maintained. In this paper, the major cases of corrosion damage experienced in LWRs in Japan and foreign countries, the causes of them and the countermeasures, the problems of hereafter and so on are described. The corrosion damage of metallic materials in the environment of LWRs occurs in the parts in contact with high temperature, high pressure water and steam, such as stainless steel piping in the primary cooling system of BWRs, and nickel alloy heating tubes of steam generators, carbon steel feed water piping and ...

52

Burner for rotary kiln; Braender til roteroven samt fremgangsmaade til dannelse af en braenderflamme med braenderen  

Energy Technology Data Exchange (ETDEWEB)

Burner for feeding a solid and a liquid or gaseous fuel to a kiln comprises a central supply pipe for liquid or gas surrounded concentrically by a first pipe providing an annular passage through which primary air is supplied. Concentrically surrounding that pipe is a second pipe providing an annular channel for supply of solid fuel in carrier air stream. The outlet end of the first concentric pipe is closed by a plate fixed mounted at the pipe end and providing multiple nozzles having their axes parallel to the burner axis. The surface of the plate facing the burning zone provides a divergence opening for the central pipe while the inner surface is formed with helical teeth. These are engaged by complementary teeth mounted on the end of the central pipe which is rotatable and biased by springs so that the teeth are in ...

1994-10-31

53

Underground piping handbook  

Energy Technology Data Exchange (ETDEWEB)

This book provides the information required to design and prepare construction drawings, and to install, inspect, test, and commission buried piping. Both pressure and gravity piping are covered, including water, steam, gases, and sewers. Directed primarily toward underground industrial piping systems, this is a succinct, well-organized compilation of practical knowledge. Checklists, examples, tables, charts, nomographs, short cuts, and helpful hints gained through years of experience complete this timely and useful ''how to'' book.

1985-01-01

54

BURST STRENGTH AND NON-DESTRUCTIVE EVALUTION OF COMPOSITE PIPES AND PIPE COUPLINGS WITH DEFECTS (TOP 48)  

Environmental Research Database

ObjectivesObjectives Not AvailableDescriptionTo determine the effects of water penetration on the burst strength of filament wound composite pipes which have been damaged by impact and then subjected to long term pressurisation with sea water. ~%~ To monitor and characterise the damage and effects of sea water penetration using ultrasonic NDT. To determine the burst strength of bonded composite pipe joints with and without defects and to see whether the defects can be detected using ultrasonic NDT. [continued...

1996-01-31

55

Influence of feed water distribution pipe replacement on the water chemistry in the steam generator at Loviisa NPP  

International Nuclear Information System (INIS)

Imatran Voima Oy , (IVO) operates two Russian designed nuclear power plants of type VVER440/213. Unit 1 has been operating since 1977 and unit 2 since 1981. First damage of feed water distribution (FWD) pipes was observed in 1989. In closer examinations FWD-pipe T-connection and distribution nozzles suffered from severe erosion corrosion damage. Similar damages have been found also in other VVER-440 type NPPs. In 1994 the first FWD-pipe was replaced by a new design mounted over the tube bundle instead of the old FWD-pipe, which was located inside the tube bundle. The purpose of this paper is to describe the new FWD-pipe and discuss its effects on the steam generator chemistry. (author)

1998-06-01

56

Bioreactors  

Energy Technology Data Exchange (ETDEWEB)

Composting is once again gaining interest among ecological engineers in view of greener industrial and residential activities. Uniform composting is needed to ensure decomposition and to keep the whole system at the same composting stage. A homogeneous temperature must be maintained throughout the media. A bioreactor design consisting of a heater core made of copper tubing was designed and tested. Two four-inch holes were made at the top and bottom of the barrel to allow air to flow through the system and promote aerobic composting. Once composting began and temperature increased, the water began to flow through the copper piping and the core heat was distributed throughout the medium. Three thermocouples were inserted at different heights on a 200 litre plastic barrel fitted with the aforementioned apparatus. Temperature variations were found to be considerably lower when the apparatus was operated with the ...

2010-07-01

57

Environmentally assisted cracking in light-water reactors: Semi-annual report, January--June 1997. Volume 24  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes work performed by Argonne National Laboratory on fatigue and environmentally assisted cracking (EAC) in light water reactors from January 1997 to June 1997. Topics that have been investigated include (a) fatigue of carbon, low-alloy, and austenitic stainless steels (SSs) used in reactor piping and pressure vessels, (b) irradiation-assisted stress corrosion cracking of Types 304 and 304L SS, and (c) EAC of Alloys 600 and 690. Fatigue tests were conducted on ferritic and austenitic SSs in water that contained various concentrations of dissolved oxygen (DO) to determine whether a slow strain rate applied during various portions of a tensile-loading cycle is equally effective in decreasing fatigue life. Slow-strain-rate-tensile tests were conducted in simulated boiling water reactor (BWR) water at 288 C on SS specimens irradiated to a low fluence in the Halden ...

1998-04-01

58

A study of Two-Phase Flow Regime Maps in Vertical and Horizontal Pipes  

Energy Technology Data Exchange (ETDEWEB)

A safety analysis code to design a pressurized water reactor and to obtain the licences including entire proprietary rights is under development in domestic research and development project. The purpose and scope of this report is to develop the flow regimes related models for inter-phase friction, wall frictions, wall heat transfer, and inter-phase heat and mass transfer in two-phase three-field equations. In order to choose choose the flow regime criteria, we have investigated various exiting best-estimate T/H codes in this chapter 2. They are the RELAP5-3D, TRAC-M, CATHARE, MARS codes. Around 500 references used in these codes have been collected and reviewed. Also we have investigated eleven papers in detail. In chapter 3, based on the selected flow regimes, the flow regime maps for a gas-liquid flow in horizontal and vertical tubes have decided including the mechanisms of flow regime transition regions. Conclusively, ...

2007-10-15

59

Augmentation of laminar flow and heat transfer in flat tubes by means of helical screw-tape inserts  

Energy Technology Data Exchange (ETDEWEB)

The heat transfer a characteristics and friction factor in the horizontal double pipes of flat tubes with full length helical screw element of different twist ratio and helical screw inserts with different spacer length are investigated. Cold and hot water are used as working fluid in tube side and shell side respectively. The experiments covered a range of Reynolds numbers 5.7 x 10{sup 2} {<=} Re {<=} 1.31 x 10{sup 3}. The effect of spacer length on the heat transfer augmentation and friction factor and the effect of twist ratio on heat transfer augmentation and friction factor have been presented separately. The study shows that, the Nusslet number (Nu) and friction factor (f) decrease with the increase of S or Y for flat tube. The comparison between the data of present plain circular with that of previous plain circular tube showed a good agreement between them but ...

2011-01-15

60

Design basis for protection of light water nuclear power plants against effects of postulated pipe rupture  

Energy Technology Data Exchange (ETDEWEB)

This standard addresses the design bases for light water reactor, nuclear power plant structures and components essential for the protection of public health and safety from the potential adverse effects of pipe whip, jet impingement, pressurization of compartments outside containment, environmental conditions and flooding associated with a postulated pipe rupture. The design bases for missile protection and the design bases for containment pressurization are not within this standard.

1981-01-01

61

American National Standard: design basis for protection of light water nuclear power plants against effects of postulated pipe rupture  

Energy Technology Data Exchange (ETDEWEB)

This standard addresses the design bases for light water reactor, nuclear power plant structures and components essential for the protection of public health and safety from the potential adverse effects of pipe whip, jet impingement, pressurization of compartments outside containment, environmental conditions and flooding associated with a postulated pipe rupture. The design bases for missile protection and the design bases for containment pressurization are not within this standard.

1980-12-31

62

Calorimetric measurements of emittance of pipe surfaces: influence of enclosure diameter, test pipe length, and an argon atmosphere  

Energy Technology Data Exchange (ETDEWEB)

Additional results using a calorimetric technique for measuring the total hemispherical emittance of pipe surfaces from 400 to 600 K are described. Two different Pyrex pipe enclosures were used, one of 15 cm i.d. and the other of 30 cm i.d. An error analysis showed that the larger diameter Pyrex pipe should have a smaller error, but the difference was negligible for the 4.4-cm test pipe diameter used. Measurements on a short length of a previously-measured pipe agreed with earlier measurements, but only over the temperature range of the measurements. While the technique normally uses a vacuum to minimize nonradiative heat transfer, measurements were done succesfully with an argon atmosphere in a closed system. A nickel-plated pipe, measured first in a vacuum and then in an argon atmosphere, allowed calculation of an effective convective ...

1981-10-01

63

The application of high pH operation to the secondary water chemistry at Genkai Nuclear Power Station  

International Nuclear Information System (INIS)

PWR plants have made efforts to maintain the long-term integrity of the steam generators (SG) by reducing the amount of corrosion products entering the secondary side of the SG. Iron entered the SG can cause several problems: degraded heat conductivity of the SG tubes in locations where iron is deposited, water level oscillations in the SG due to tube support plate hole blockage, and initiation and propagation of inter-granular attacks (IGA) and stress corrosion cracking (SCC). One of the most effective measures, high all-volatile treatment (AVT) chemistry has been applied to actual plants to reduce the flow-accelerated corrosion (FAC) coming from the carbon steel piping. The secondary water chemistry at Genkai NPS 1 and 2 changed, from the Low AVT chemistry to the High AVT chemistry, in November 2006. In this paper, we will describe the results of experiments in applying the use of High pH ...

2009-02-01

64

Structural integrity evaluation of fuel test loop submerged in water subjected to postulated pipe rupture  

Energy Technology Data Exchange (ETDEWEB)

The structural integrity of the Fuel Test Loop(FTL) in a Korean experimental reactor is evaluated when the FTL, submerged in a water environment, is subjected to a postulated pipe rupture. The analyses are performed under static and dynamic conditions, imposing the thrust force history at each postulated pipe rupture section. Through analysis the following results are found: 1) A double ended guillotine can not be expected based on the toughness of the material, 2) the structural integrity of the chimney surrounding the FTL would not impede the structural integrity by the pipe whip. All analyses are performed by finite element methods.

2000-02-01

65

Environmentally assisted cracking in light water reactors. Semiannual report, October 1993--March 1994. Volume 18  

International Nuclear Information System (INIS)

This report summarizes work performed by Argonne National Laboratory (ANL) on fatigue and environmentally assisted cracking (EAC) in light water reactors (LWRs) during the six months from October 1993 to March 1994. EAC and fatigue of piping, pressure vessels, and core components in LWRs are important concerns in operating plants and as extended reactor lifetimes are envisaged. Topics that have been investigated include (a) fatigue of low-alloy steel used in piping, steam generators, and reactor pressure vessels, (b) EAC of wrought and cast austenitic stainless steels (SSs), and (c) radiation-induced segregation and irradiation-assisted stress corrosion cracking (IASCC) of Type 304 SS after accumulation of relatively high fluence. Fatigue tests have been conducted on A302-Gr B low-alloy steel to verify whether the current predictions of modest decreases of fatigue life in simulated pressurized water ...

2007-09-01

66

CATHENA simulation of the WOLSUNG D_20 spill incident of 1984 November 25  

International Nuclear Information System (INIS)

The CATHENA (formerly ATHENA) has been used to simulate the thermalhydraulic behaviour of the WOLSUNG-1 CANDU-600 reactor during the D_20 spill incident of 1984 November 25. A 4-inch (nominal) Liquid Relief Valve inadvertently opened in the reactor auxiliary system during normal reactor operation, resulting in a discharge of heavy water from the primary heat transport system. The valve remained open for approximately 29 minutes. CATHENA is an advanced thermalhydraulic computer code for analysis of postulated loss-of-coolant accidents (LOCA) and transient faults in CANDU nuclear reactors. A full two-fluid (six-equation) representation of the two-phase flow is used. Component models are used to represent pumps, valves, critical discharge, etc., which are necessary to describe the behaviour of the CANDU system under upset conditions. Heat transfer between the fluid and piping walls (or fuel) is modelled ...

1986-06-09

67

Unclas - NASA Technical Report Server (NTRS)  

Science.gov (United States)

COMPUTER PROGRAM GRADE. FOR DESIGN AND ANALYSIS. OF GRADED-POROSITY HEAT-PIPE. WICKS. Contract No. NAS 2-8310. August 1974. Prepared by. J. E. Eninger ...

69

A heating surface  

Energy Technology Data Exchange (ETDEWEB)

A design is proposed for forming the rear screen of a chamber firebox at the point of aerodynamic projection and a design for attaching the pipes of the aerodynamic projection using girders linked with the screen by hinges and movable connections.

1982-01-01

70

Gas-fired boiler plant  

Energy Technology Data Exchange (ETDEWEB)

A gas-fired boiler plant comprises a burner bed extending over a flat surface and heat exchanger pipes arranged above the burner bed, parallel to the said surface. The heat exchanger tubes comprise pipes equipped with a pluraltiy of flat ribs which extend substantially radially from the said pipes and which are provided in space arrangement over the length of the said heat exchanger pipes. The ribs are provided with bent-off portions. The hot flue gases rising from the burner bed flow through the gaps formed between the said ribs and pipes. In order to improve both the convective heat transmission and the utilization of the radiant heat, the bent-over edges are inclined, at least partly, relative to the surface of said burner bed, the arrangement being selected in a manner to ...

1989-10-10

71

Apparatus for total hemispherical emittance measurements of full-scale receiver pipes from 100 to 300 C  

Energy Technology Data Exchange (ETDEWEB)

An apparatus is described for measuring the total hemispherical emittance of pipes of a length suitable for use in a prototype solar collector. The calorimetric method used requires measurements of the temperatures of the surface of the test pipe and of a concentric outer cylinder and measurement of the electrical power used to heat the test pipe. Measurements were made of the total hemispherical emittance of black chrome, nickel, and bare steel pipes as a function of temperature. The emittance of the black chrome surfaces increased significantly from an extrapolated value of about 0.1 at 25 deg C to values on the order of 0.3-0.4 at 300 deg C. The extrapolated values for black chrome agreed with measurements made using other techniques at room temperature. The results for the nickel-plated pipe agreed with total emittance calculated from spectral reflectance ...

1981-01-01

72

The effect of the shear rate-dependent thermal conductivity of non-Newtonian fluids on the heat transfer in a pipe flow  

Science.gov (United States)

The present study investigates the effect of the shear rate-dependent thermal conductivity of non-Newtonian fluids on the heat transfer enhancement in a pipe flow. The constant heat flux as thermal boundary condition was adopted in the thermally developed region. The present analytical results show the heat transfer enhancement over those of a shear rate-independent thermal conductivity fluid. The heat transfer coefficient ratio (h/h{sub 0}) linearly increase with the non-dimensional average velocity difference which is the product of the shear rate-dependence of the thermal conductivity and wall-shear rate.

1996-09-01

73

Nuclear desalination for the petrochemical complex of the Natuna project  

International Nuclear Information System (INIS)

On the basis of environmental considerations, a high temperature gas cooled reactor (HTGR) was proposed as the heat source for the Natuna project for CO_2 conversion. To convert CO_2 to useful products, a large amount of high quality water is required for the chemical processes, boilers and other purposes. One LNG production train (maximum of six trains) would produce 0.4 x 10"9 SCF/d of saleable gas and 1.4 x 10"9 SCF/d of CO_2 (in the case of the Exxon process). This CO_2 gas would then be converted to automobile fuel (methane, methanol), which requires a large amount of water. Natural gas from an off- shore gas field is piped to the petrochemical complex on Natuna Island (about 228 km). Natuna is a small island that, apart from sea water, does not have much available water. The desalination process is considered to be the only solution to the ...

1997-12-01

74

Structural integrity evaluation of FTL in-pool piping  

Energy Technology Data Exchange (ETDEWEB)

HANARO fuel test loop will be equipped in HANARO to obtain the development betterment of advanced fuel and materials through the irradiation test. The object of this study is to evaluate the structural integrity of FTL in-pool piping by investigating a dynamic analysis of the loop containing a postulated rupture section. The method to perform the dynamic analysis and structural integrity evaluation caused by the pipe whip in water environment can be a reference for a similar structural integrity evaluation. (author). 7 refs., 39 tabs., 34 figs.

1998-05-01

75

Integrity of feedwater and main steam piping in KWU light water reactor plants  

Energy Technology Data Exchange (ETDEWEB)

New standard catalogs for piping, supports, and valves have been introduced by Kraftwerk Union (KWU) for the first time in its Convoy series of PWR plants. These catalogs, underlying regulatory codes, and newly developed KWU specifications are described. Feedwater and main steam piping systems within the containment, including pipe supports and valves, are used to demonstrate the high quality level of piping technology achieved in the Federal Republic of Germany. Such quality standards ensure the integrity of single components as well as of the entire system, so that, under certain conditions, pipe whip restraints against postulated breaks have become unnecessary. The quality aspects apply basically for both PWR and BWR plants of KWU.

1986-07-01

76

Enhanced heat transfer through oscillatory flow  

Energy Technology Data Exchange (ETDEWEB)

The enhancement of longitudinal heat transfer by means of fluid pulsation in a pipe has been investigated analytically and numerically, including the transient state. The effects of pulsation amplitude, frequency, and pipe length on thermal properties such as effective thermal diffusivity and delay time are clarified. Their effects on numerical calculations are also presented and suggestions for efficient numerical calculations of this problem are made concerning the combination of parameters.

1994-03-01

77

Device for energy-saving heating of fuel in the fuel supply for an internal combustion engine  

Energy Technology Data Exchange (ETDEWEB)

The invention concerns a device for the energy-saving heating of fuel in the supply pipe to an internal combustion engine to regain energy from the fuel itself, particularly but not exclusively for a Diesel engine. A part of the quantity of heat added to the fuel between the tank and the injection nozzles is given up by excess fuel not to the tank, but to the fuel lifted upstream of the injection pump. The device is characterised by the fact that it has a heat exchanger, which absorbs heat from the fuel at the level of the injection pump or upstream of it, and takes this to the fuel above the injection pump. The heat exchanger is preferably mounted upstream of a filter and close to it. A bridging pipe, which may be integrated in the heat exchanger, permits the heat exchanger to be short-circuited ...

1981-02-10

78

Feasibility study for use of the natural convection shutdown heat removal test facility (NSTF) for VHTR water-cooled RCCS shutdown  

International Nuclear Information System (INIS)

In summary, a scaling analysis of a water-cooled Reactor Cavity Cooling System (RCCS) system was performed based on generic information on the RCCS design of PBMR. The analysis demonstrates that the water-cooled RCCS can be simulated at the ANL NSTF facility at a prototypic scale in the lateral direction and about half scale in the vertical direction. Because, by necessity, the scaling is based on a number of approximations, and because no analytical information is available on the performance of a reference water-cooled RCCS, the scaling analysis presented here needs to be 'validated' by analysis of the steady state and transient performance of a reference water-cooled RCCS design. The analysis of the RCCS performance by CFD and system codes presents a number of challenges including: strong 3-D effects in the cavity and the RCCS tubes; simulation of turbulence in flows characterized by natural ...

79

Tensile properties and bending formability of drawn magnesium alloy pipes  

Energy Technology Data Exchange (ETDEWEB)

Magnesium alloys are being increasingly utilized in a variety of fields as an alternative material to organic materials and aluminum alloys, owing to excellent properties. Those include low density, and excellent damping properties. When compared to organic materials, furthermore, Mg alloy excels at recyclability, heat radiation, and electromagnetic-shielding. Though most of magnesium alloy products are manufactured through die-casting and thixo-molding at present, the demand for the expanding of magnesium wrought alloy market is increasing. Taking full advantage of a drawing technique and applying it to the conventional extruded pipe, we have developed a new type of magnesium alloy pipe. The strength of the developed pipe is significantly higher than that of the conventional one, either extruded or die-casting. Some of the excellent properties were obtained from fundamental tests performed with the ...

2003-07-01

80

Applicability of leak-before-break criteria  

Energy Technology Data Exchange (ETDEWEB)

On February 1, 1984, the US Nuclear Regulatory Commission issued Generic Letter 84-04 on the subject of postulated pipe breaks in pressurized water reactor (PWR) primary coolant loops, opening the way for pipe-whip restraint exemptions. The letter substitutes the leak-before-break (LBB) criteria for the double-ended guillotine break regarding PWR primary reactor coolant system (RCS) piping and asymmetric blowdown loads. The LBB criterion refers to the fact that a piping flaw will leak before it breaks. The current requirement to provide pipe-whip restraints is applied within the plant to all high-energy piping with a potential for damaging structures, systems, and components essential to safe reactor shutdown. This includes primary RCS piping 30 in. and larger as well as smaller piping systems. A ...

1986-01-01

81

Development of a geothermal heat pump. Final report  

Energy Technology Data Exchange (ETDEWEB)

In the development of a geothermal heat pump a water source heat pump was connected to a 1-1/2'' water line, 2200' long, buried in an endless loop 10' deep. The system is closed, circulating the same water continuously through the heat pump back to the field again. This water line 10' deep is the geothermal heat source. No matter how cold the air temperature gets on a winter day the water temperature to the heat pump will always be above 45/sup 0/F. This system has efficiently heated our house the past year using no supplemental heat.

1981-11-02

82

Lead exposure via drinking water - unnecessary and avoidable  

International Nuclear Information System (INIS)

Despite successful reduction of the general lead exposure, this heavy metal is still a matter of public concern due to the fact that associations with intellectual impairment or delayed puberty are found to correlate with very low lead blood concentrations. Lead in tap water is still an important contribution to lead exposure which may cause health risk for infants. Therefore, lead pipes should be completely sanitated by exchange against pipes made from more healthy materials. (orig.)

83

Design and Operation of a Novel Capillary Pumped Two-Loop System for Cooling of Electronic Devices  

British Library Electronic Table of Contents (United Kingdom)

Heat pipes, loop heat pipes (LHP), and capillary pumped loops (CPL) have already proven their potential to remove high heat fluxes from a small electronic device and transport the heat to a heat sink that is large enough to transfer it into the ambient air. We introduce a novel two-loop system similar in design to CPLs but with an additional buoyancy-driven fluid loop. Non-degassed methanol is used as a working fluid. Key benefits compared to LHPs and CPLs are easy filling procedure, easy startup, and the tolerance toward noncondensable gases in the fluid. The amount of fluid in the system can be varied over a broad range without affecting the heat transfer performance. Three different inverted-meniscus-type evaporators have been employed in this study. A maximum evaporator heat transfer r...

2012-01-01

84

Application of leak-before-break approach to PWR piping designed by Babcock and Wilcox: Final report  

Energy Technology Data Exchange (ETDEWEB)

Recently, the leak-before-break (LBB) concept has been used successfully to eliminate some pipe whip restraints, snubbers and jet impingement shields from the primary reactor cooling system piping of pressurized water reactors. This has resulted in substantial savings in maintenance costs, reductions in radiation exposure of plant service personnel, and has enhanced the overall safety of nuclear power plants. This study provides guidelines to utilities in expanding the application of the LBB concept to additional pipe systems and it couples the concept with hardware optimization. Seven high energy piping systems were investigated for technical feasibility in using the LBB concept. The results indicate that some of these seven lines are good candidates for the leak-before-break application.

1987-01-01

85

Serviceability of steam generators at NPPs with reactors of the WWER-440 and WWER-1000 types  

Energy Technology Data Exchange (ETDEWEB)

Steam generators (SG) are the weak link of nuclear power plants, their service life is shorter than the service life of other NPP components. This paper is dedicated to a statistical analysis of SG damages and failures. Heat exchanging tubes (HET) are the most damaged elements in SG, there are on average 286 plugged or repaired tubes in each operating SG. The usually mechanisms of tube failure are the following: denting, corrosion at tube outside, pitting, fretting, and circular crack propagation. Most of damages are located in the transition zone above a tube plate. This study shows that the factors that are involved in the SG HET fault probability are: - design features of SG and secondary equipment elements (high pressure feed heaters (HPFH), low pressure feed heater (LPFH)), - water chemistry at different points of condensate feed pipe, composition and density of deposits on HET surface, efficiency of mechanical and ...

2002-07-01

86

Simulation experiments for hot-leg U-bend two-phase flow phenomena  

International Nuclear Information System (INIS)

In order to study the two-phase natural circulation and flow termination during a small break loss of coolant accident in LWR, simulation experiments have been performed. Based on the two-phase flow scaling criteria developed under this program, an adiabatic hot leg U-bend simulation loop using nitrogen gas and water and a Freon 113 boiling and condensation loop were built. The nitrogen-water system has been used to isolate key hydrodynamic phenomena from heat transfer problems, whereas the Freon loop has been used to study the effect of phase changes and fluid properties. Various tests were carried out to establish the basic mechanism of the flow termination and reestablishment as well as to obtain essential information on scale effects of parameters such as the loop frictional resistance, thermal center, U-bend curvature and inlet geometry. In addition to the above experimental study, a preliminary modeling study has been ...

1986-10-27

87

Simulation experiments for hot-leg U-bend two-phase flow phenomena  

Energy Technology Data Exchange (ETDEWEB)

In order to study the two-phase natural circulation and flow termination during a small break loss of coolant accident in LWR, simulation experiments have been performed. Based on the two-phase flow scaling criteria developed under this program, an adiabatic hot leg U-bend simulation loop using nitrogen gas and water and a Freon 113 boiling and condensation loop were built. The nitrogen-water system has been used to isolate key hydrodynamic phenomena from heat transfer problems, whereas the Freon loop has been used to study the effect of phase changes and fluid properties. Various tests were carried out to establish the basic mechanism of the flow termination and reestablishment as well as to obtain essential information on scale effects of parameters such as the loop frictional resistance, thermal center, U-bend curvature and inlet geometry. In addition to the above experimental study, a preliminary modeling study has been ...

1986-01-01

88

A phenomenological model of the thermal hydraulics of convective boiling during the quenching of hot rod bundles  

International Nuclear Information System (INIS)

In this paper, a phenomenological model of the thermal hydraulics of convective boiling in the post-critical-heat-flux (post-CHF) regime is developed and discussed. The model was implemented in the TRAC-PF1/MOD2 computer code (an advanced best-estimate computer program written for the analysis of pressurized water reactor systems). The model was built around the determination of flow regimes downstream of the quench front. The regimes were determined from the flow-regime map suggested by Ishii and his coworkers. Heat transfer in the transition boiling region was formulated as a position-dependent model. The propagation of the CHF point was strongly dependent on the length of the transition boiling region. Wall-to-fluid film boiling heat transfer was considered to consist of two components: first, a wall-to-vapor convective heat-transfer portion and, second, a wall-to-liquid ...

1983-10-14

89

Thermally isolated pipeline  

Energy Technology Data Exchange (ETDEWEB)

The pipelines is provided for gases, particluarly helium, at temperature of about 1000/sup 0/C (pressure about 40 bar) and is used as the connection be tween a gas cooled high temperature reactor and a heat load. The pipe consists of a temperature-resistant inner tube, which is composed of several pipe sections, which are supported on ball bearings, and a gas tight pressurised outer tube. There are supports and insulation between the two tubes. The sub-claims concern fixing of and bearings for the pipe sections. The description is very detailed and supplemented by drawings.

1980-08-28

90

Initiation process of type 1 pitting corrosion on copper water-tubes; Reisui yo dokan ni okeru 1 gata koshoku no hassei  

Energy Technology Data Exchange (ETDEWEB)

Copper tubes have been widely used for water supply and heat exchangers. In such systems copper tubes often suffer from type 1 pitting-corrosion. A mechanism, of the type I pitting-corrosion on copper tubing has been presented, but a initiation mechanism of the pitting corrosion is still unknown. In this paper we aimed to clarify the initiation mechanism of the pitting corrosion. Copper-tube specimens were immersed in a circulating solution. The solution had been used for heat exchangers at a Japanese factory where the water leakage occurred by the pitting corrosion on copper tubes. The solution contained tiny precipitates resulted from corrosion of galvanized steel pipe. During the immersion test changes in the surface state of a copper tube was analyzed by in situ RAMAN (in situ Raman Spectroscopy), SEM (Scanning Electron Microscope), EPMA (Electron Probe Microanalysis), AES ...

1999-07-15

91

Control rod devices  

International Nuclear Information System (INIS)

Purpose: To remove excessive driving pressure applied to an unisolated control rod drive by returning excessive coolant to a condensed water storage tank or to the inlet side of a drive water pump using a coolant flow rate control pipe of a control rod driving hydraulic system. Constitution: Excessive water is returned to a condensed water tank while controlling the excessive coolant by a flow control valve in response to variations in the pressure difference between the reactor pressure and the driving water line when the control rods are isolated using a pipe from the outlet side of the drive water pump to the condensed water storage tank. Thus, the control rod to be isolated is prevented form being dropped. (Sekiya, K.).

92

The study of thermal characteristics of high temperature oven for atomic spectroscopy  

International Nuclear Information System (INIS)

We present a high temperature heat oven with merits of conventional heat pipe oven and study ots thermal characteristics. The oven consists of stainless steel body and heating part of three layers of ceramic tubes. We obtained the maximum temperature of about 1350. deg. C at the center which was measured by thermocouple and infrared thermometer. And we compared the heating characteristics in the cases of external heating and no extent heating. It was applied to self diffraction experiment in the samarium gas which was one of the high melting point material.

1997-11-01

93

Freezing phenomena in ice-water systems  

Energy Technology Data Exchange (ETDEWEB)

The characteristics of solidification and melting are reviewed. The properties of water and ice and the phase diagram of water are discussed with special emphasis on ice density. A concise account of the freezing process and the Stefan problem is presented. To this end, the four stages of freezing are identified, supercooling, nucleation and the formation of dendritic ice, the growth of concentric rings of solid ice at 0{sup o}C and the final cooling of the solid ice are treated in some detail. The subject of bursting of pipes is given particular emphasis. Attention is drawn to a common misconception on pipe bursting and to misleading relationships for the computation of freezing time for ice blockage. Several current applications of melting and freezing systems are outlined. (author)

2002-09-01

94

Analysis of postulated FFTF pipe ruptures  

International Nuclear Information System (INIS)

A detailed assessment of the FFTF Primary Heat Transport System (PHTS) piping has led to the conclusion that the integrity of the piping is assured such that there is no realistic potential for a rupture. Nevertheless, consistent with the practice of showing design margins even for hypothetical events, a spectrum of postulated PHTS ruptures has been analyzed. The analyses showed that upstream of the reactor vessel inlet downcomer, rupture areas of any size including a double-ended rupture could be tolerated with no core coolant boiling. At the most limiting location, the reactor inlet nozzle, rupture areas of 75 in."2 and 55 in."2 could be tolerated for three-loop and two-loop operation, respectively. This paper will present the following: (1) the criterion with which consequences of postulated pipe ruptures are compared; (2) the general transient response of the FFTF to postulated ruptures; and (3) the ...

95

Abrasion wear protection in coal mining  

Energy Technology Data Exchange (ETDEWEB)

A brief description is given of some commercially-available wear-resistant products suitable for use in mine environments. The materials are cast basalt, cast or sintered alumina, and a heat-treated martensitic iron, and they can be used as linings for pipes, bunkers and chutes.

1985-05-01

96

Analysis of chlorinated polyvinyl chloride pipe burst problems :Vasquez residence system inspection.  

Energy Technology Data Exchange (ETDEWEB)

This report documents the investigation regarding the failure of CPVC piping that was used to connect a solar hot water system to standard plumbing in a home. Details of the failure are described along with numerous pictures and diagrams. A potential failure mechanism is described and recommendations are outlined to prevent such a failure.

2005-10-01

97

Probabilistic fracture assessment of TAPP 3-4 PHT piping  

International Nuclear Information System (INIS)

Methodology based on probabilistic fracture mechanics (PFM) is finding increasing acceptability in demonstrating safety of Nuclear Power Plant (NPP) piping. In PFM, the methods of fracture mechanics and reliability theory are combined for assessing the reliability of components, which contain cracks. In this work, reliability assessment of Tarapur Atomic Power Plant (TAPP) 3-4 Primary Heat Transport (PHT) piping is done using PFM. Monte Carlo simulation with stratified sampling is used as a variance reduction technique. PFM model assumes a pre-existing circumferential surface crack before the start of plant operation. The crack grows in size during the lifetime of the plant due to the fatigue loading. This part-through wall crack having escaped hydro-test and pre-service inspection, may result in either a through wall flaw (leak) or may lead to the rupture of the piping. R6 method is used as failure ...

2005-12-01

98

Heat exchange enhancement structure  

Energy Technology Data Exchange (ETDEWEB)

A passive heat exchange enhancement structure which operates by free convection includes a flat mounting portion having a plurality of integral fins bent outwardly from one side edge thereof. The mounting portion is securable around a stovepipe, to a flat surface or the like for transferring heat from the pipe through the fins to the surrounding air by rotation-enhanced free convection.

1980-12-02

99

Wall thinning trend analyses for secondary side piping of Korean NPPs  

International Nuclear Information System (INIS)

Since the mid-1990s, nuclear power plants in Korea have experienced wall thinning, leaks, and ruptures of secondary side piping caused by flow-accelerated corrosion (FAC). The pipe failures have increased as operating time progresses. In order to prevent the FAC-induced pipe failures and to develop an effective FAC management strategy, KEPRI and KOPEC have conducted a study for developing systematic FAC management technology for secondary side piping of all Korean nuclear power plants. As a part of the study, FAC analyses were performed using the CHECWORKS code. The analysis results were used to select components for inspection and to determine inspection intervals on each nuclear power plant. This paper describes the introduction of the FAC analysis method and the wall thinning trend analysis results by reactor type, system, and water treatment amine. This paper also represents the ...

2003-08-17

100

Development of a combined ultrasonic and eddy current inspection system for examination of the internal surfaces of water-filled austenitic piping  

Energy Technology Data Exchange (ETDEWEB)

After October 1993, Swedish BWR power plant operators will be required to present an inspection concept which will facilitate the nondestructive examination of recirculation system piping. According to the pertinent Swedish codes and standards, such inspections will be required to focus on internal pipe surfaces. Since it is impossible for external inspections to cover all essential areas with the necessary degree of sensitivity (geometry, beam attenuation), Siemens-KWU was commissioned to develop an inspection system which combines ultrasonic search units and eddy current probes to produce the required degree of examination sensitivity. A pipe crawler was developed to transport the inspection unit. This device can be used for the inspection of circumferential and longitudinal pipe welds, nozzle-to-pipe welds and RPV nozzle-to-shell welds. Special probes designed to fulfill ...

1994-12-31

101

Increasing concentrations of trihalomethanes (THMs) in a drinking water distribution network; Trihalometanos (THMs) en una red de distribucion de agua potable en alta  

Energy Technology Data Exchange (ETDEWEB)

THMs are disinfection by-products (DBPs) generated during water chlorination. Concentration of individual and total THMs, depends on treatment process and THMs precursors level. ATLL water utility has two DWTP (Llobregar and Ter) that produce and supply drinking water to Barcelona and regional area. This work studies the levels of THMs along the ATLL distribution system (450 km). Although, no differences were observed along water pipes system, changes of water resource and mix procedures were related. (Author) 12 refs.

1999-07-01

102

Eliminating incrusted solids in drinking water conduits in Cantillana, Seville, Spain; Eliminacion de los solidos incrustados en las conducciones de agua potable de Cantillana (Sevilla)  

Energy Technology Data Exchange (ETDEWEB)

The presence of iron and manganese in underground water due to rock leaching may cause problems in drinking water. the oxidation of these metals produces precipitates which alter water quality (by making it cloudy and bad testing) and may even block supply pipes. This article presents a way eliminating this problem which was tried out in the conduits of Cantillana, a municipality in the province of Seville, Spain. Cleaning the pipes with a mixture of H{sub 2}O{sub 2} + water changes the characteristics of the deposits from flocculant and absorbent to sandy following which they are washed away by the pressure of the water. Once the pipes have been cleaned, a minimal amount of maintenance will prevent the formation of new deposits. This article thus a relatively simple and economical solution for recovering ...

1998-12-01

103

Condensation driven water hammer studies for feed water distribution pipe  

International Nuclear Information System (INIS)

Special T-shaped feedwater distribution pipes were installed in steam generators at the Loviisa (Finland) and Rovno (Russia) nuclear power plants. The new shape was tested in an extensive testing programme. Since the tubes frequently suffer from corrosion damage, large-scale water hammer experiments were performed on a model facility in 1996. The main objectives of the water hammer experiments were to find out the prevailing parameters leading to water hammers, as well as the sensitivity of hammering to boundary conditions. A water hammer may occur when the mass flow rate into the steam generator exceeds 6 kg/s and the temperature difference between steam generator and feedwater exceeds 100 degC. Visual experiments and stress analyses of the pipe were also carried out. The weakest part, the T-joint, may hold against such water hammers only ...

1997-05-26

104

Practical operation of a trumpet secondary concentrator with a cavity receiver at elevated temperatures  

Energy Technology Data Exchange (ETDEWEB)

A prototype trumpet type nonimaging secondary concentrator was designed and fabricated for use with the Cummins Power Generation (CPG) 7.5 kW{sub e} dish-Stirling system. A set of operational tests was carried out with a high temperature heat pipe receiver and gas-gap calorimeter. These tests have successfully alleviated any operational concerns about the effectiveness of active water cooling for such devices. The authors obtained over two full days of testing with the cavity receiver operating at its design temperature of 660 C while the trumpet throat temperature remained {approx_equal} or less than 100 C. In addition, these tests have shown that the thermal isolation of the trumpet from the hot receiver is very effective. Highly variable insolation, instabilities in the temperature controller on the calorimeter, and a poor match between the optical quality of the primary and the design of the trumpet have made detailed ...

1997-12-31

105

Demonstration and Evaluation of Magnetic Descalers.  

Science.gov (United States)

Mineral scale formation in water distribution piping impedes flow, resulting in pressure and volume reduction and increasing operational costs. Chemical cleaning is both costly and time consuming, and there are health concerns when chemically cleaning pot...

2001-01-01

106

Determining effective soil formation thermal properties from field data using a parameter estimation technique  

Energy Technology Data Exchange (ETDEWEB)

A one-dimensional thermal model is derived to describe the temperature field around a vertical borehole heat exchanger (BHEx) for a geothermal heat pump. The inlet and outlet pipe flows are modeled as one, and an effective heat capacity is added to model the heat storage in the fluid and pipes. Parameter estimation techniques are then used to estimate various parameters associated with the model, including the thermal conductivity of the soil and of the grout which fills the borehole and surrounds the u-tube. The model is validated using test data from an experimental rig containing sand with known thermal conductivity. The estimates of the sand thermal conductivity derived from the model are found to be in good agreement with independent measurements.

1998-11-01

107

Determining Effective Soil Formation Thermal Properties From Field Data Using A Parameter Estimation Technique  

Energy Technology Data Exchange (ETDEWEB)

A one-dimensional thermal model is derived to describe the temperature field around a vertical borehole heat exchanger (BHEX) for a geothermal heat pump. The inlet and outlet pipe flows are modeled as one, and an effective heat capacity is added to model the heat storage in the fluid and pipes. Parameter estimation techniques are then used to estimate various parameters associated with the model, including the thermal conductivity of the soil and the grout that fills the borehole and surrounds the U-tube. The model is validated using test data from an experimental rig containing sand with known thermal conductivity. The estimates of the sand's thermal conductivity derived from the model are found to be in good agreement with independent measurements.

1999-01-01

108

Monitoring drinking water networks by data telemanagement; Telegestion de datos para control de redes de agua potable  

Energy Technology Data Exchange (ETDEWEB)

The WIT telemanagement system simply, reliably and efficient by makes available to us in real time processed, ordered and managed data. Such information has been used to optimise the performance of the drinking water distribution networks on a number of housing estates. This has led to major saving in consumption and on equipment maintenance, thereby improving customer service and obtaining a more rational use of piped water. (Author)

1997-04-01

109

Fundamental study of heat transfer augmentation by smooth turbulence surface promotors  

International Nuclear Information System (INIS)

In the utilization of the thermal energy by ocean temperature difference and factory waste heat, the high performance heating surfaces in pipes from which scale can be removed are required. As the method of removing scale, the method using sponge balls seems most suitable, but for applying this method, as the form of the protrusions attached to the inner surfaces of pipes, smooth circular are form is desirable. The promotion of heat transfer with the rows of circular arc protrusions like this is strongly related to the mode of flow and such structure as separation, recirculation flow, readhesion and turbulent energy generation. In this study, as the basic research to optimize the heating surface with the rows of smooth protrusions, the flow characteristics and the heat transfer characteristics including the turbulent structure of the wake of ...

1985-01-01

110

Underground Mine Water Heating and Cooling Using Geothermal Heat Pump Systems  

Energy Technology Data Exchange (ETDEWEB)

In many regions of the world, flooded mines are a potentially cost-effective option for heating and cooling using geothermal heat pump systems. For example, a single coal seam in Pennsylvania, West Virginia, and Ohio contains 5.1 x 1012 L of water. The growing volume of water discharging from this one coal seam totals 380,000 L/min, which could theoretically heat and cool 20,000 homes. Using the water stored in the mines would conservatively extend this option to an order of magnitude more sites. Based on current energy prices, geothermal heat pump systems using mine water could reduce annual costs for heating by 67% and cooling by 50% over conventional methods (natural gas or heating oil and standard air conditioning).

2006-03-01

111

Thermal gradient humidification-dehumidification desalination system  

Energy Technology Data Exchange (ETDEWEB)

A solar energy desalination process utilizing solar radiation directly for the evaporation of salt water is described. Ambient air takes on water vapor as the air passes through an evaporative medium. It is then directed between a saline water-covered, solar absorbing surface and a solar collecting housing. The resulting heated and moisture-saturated air is cooled in a heat exchange means where condensation of fresh water occurs. Simultaneously, cool salt water is utilized as the cooling water in the heat exchange means, and takes on the heat of condensation given up by the condensing vapor. The heated salt water from the heat exchange means is partially directed over the solar absorbing surface, and at least a ...

1982-12-14

112

Potential migration of organic pollutants in pipes of polyethylene. Study in pipelines of distribution net of drinkable water; Migracion potential de contaminantes organicos en tubos de polietileno. Estudio en tuberias de red de distribuciond e agua potable  

Energy Technology Data Exchange (ETDEWEB)

Polyethylene pipes and connections are being widely used in treated water distribution services. Migration of low molecular weight compounds from the polyethylene into the water can change its final quality. This paper is about the concentrations and identification of the migration compounds found in treated water after staying in contact with low and high-density polyethylene. Identification and quantification were carried out using CLSA (Closed Loop Stripping Analysis) extraction technique and gas chromatography coupled to mass spectrometry (HRGC/HRMS). (Author) 12 refs.

2002-07-01

113

Coolant rate distribution in horizontal steam generator under natural circulation  

International Nuclear Information System (INIS)

The interrelations between the factors causing the main effects on the primary circuit coolant flow rate distribution in the horizontal steam generator pipes in reactor facilities with the WWER type reactors under the modes with natural circulation are discussed. The criterion showing the presence or absence of coolant circulation reversal in bottom rows of the steam generator pipes is obtained. It is shown that large hydraulic non-uniformity in steam generator pipes operating in parallel under coolant natural circulation leads to decreasing the heat transfer surface efficiency under reactor facility emergency cooling, restricts its servicing capabilities. The circulation reverse in steam generator pipes under coolant natural circulation mode can give unfavourable effect on separate structural elements of the steam generators and as a result it can cause additional temperature ...

1997-09-01

114

Two-phase flow patterns and frictional pressure gradients in a small, horizontal, rectangular channel  

Energy Technology Data Exchange (ETDEWEB)

Two-phase flow patterns and frictional pressure gradients in flow in small, rectangular channels are being studies as part of a larger research program addressing phase-change heat transfer of pure refrigerants and refrigerant mixtures in plate-fin heat exchangers. Small rectangular flow channels were selected as representative of plain fin geometries. The particular channel reported herein has dimensions of 19.05 {times} 3.18 mm. Adiabatic flows of air/water mixtures, with the flow channel horizontal and the channel exit at near-atmospheric conditions, were utilized in the experiments. Analysis and interpretation of the pressure data relative to observed flow pattern transitions led to an objective method for determining the plug/bubble-to-slug flow transition. This method, together with visual observations, supplemented with photographic data, was used to develop a flow pattern man. A comparison of existing flow pattern ...

1990-05-01

115

User's guide on butt heat-fusion joining of polyethylene gas pipes. Topical report, July 1986-September 1989. Volume 1  

Energy Technology Data Exchange (ETDEWEB)

Heat fusion is the most common joining method for polyethylene gas distribution piping. Butt fusion was studied with the intent of relating the quality of the joint to the joining conditions. A semi-empirical approach was used. The thermofluid consequences of joining conditions such as heater temperature, heating time and joining parameter were calculated using a computer model. The model was validated by instrumented tests. The strength of the joints was gauged by destructive mechanical testing. Tensile and tensile impact tests were used. Over 150 joints were fabricated using four different polyethylene resins. Most of the data are given in GRI Report No. 88/0276.2 -- Volume 2: Technical Reference on Butt Heat Fusion Joining of Polyethylene Gas Pipes. A parameter, termed the Joining Parameter, was found to characterize the joining conditions. Of the mechanical tests parameters, the ...

1989-09-01

116

Technical reference on butt heat-fusion joining of polyethylene gas pipes. Topical report, July 1986-September 1989. Volume 2  

Energy Technology Data Exchange (ETDEWEB)

Heat fusion is the most common joining method for polyethylene gas distribution piping. Butt fusion was studied with the intent of relating the quality of the joint to the joining conditions. A semi-empirical approach was used. The thermofluid consequences of joining conditions such as heater temperature, heating time and joining parameter were calculated using a computer model. The model was validated by instrumented tests. The strength of the joints was gauged by destructive mechanical testing. Tensile and tensile impact tests were used. Over 150 joints were fabricated using four different polyethylene resins. Most of the data are given in GRI Report No. 88/0276.2 -- Volume 2: Technical Reference on Butt Heat Fusion Joining of Polyethylene Gas Pipes. A parameter, termed the Joining Parameter, was found to characterize the joining conditions. Of the mechanical tests parameters, the ...

1989-09-01

117

A thermal valve heat flux control device  

International Nuclear Information System (INIS)

In order to evacuate the residual power in a nuclear reactor, a thermal valve system is presented for the modification of the heat exchange conditions at the pool exchanger level, which avoids the use of mechanical valves on the pipes. The system involves a vessel containing the exchanger, with openings at the upper end of the vessel and means for feeding the fluid at the lower end, and means for controlling the opening width.

1994-10-05

118

Corrosion on stainless steel in high concentrated sulphuric acid under flow- and fatigue loading conditions. Stroemungs- und schwingungsbeeinflusste Korrosion von nichtrostenden Staehlen in konzentrierter Schwefelsaeure; Schlussbericht  

Energy Technology Data Exchange (ETDEWEB)

It was to be investigated why inexplicable cracking occurred in plain stainless austenitic steel pipes of heat exchangers in discrete sites of the inner surface exposed to acid even with anodic corrosion protection, and what countermeasures must be taken. The following materials were investigated: X 6 CrNiTi 18 10 and X 6 CrNiMoTi 17 12 2. The influence of mechanical vibrations on passive film formation and destruction was investigated in unconstrained pipes and pipes constrained at one end in conditions of anodic protection at frequencies of 0 to 160 Hz and temperatures of 98 to 130 degrees Centigrade in 98% sulphuric acid. The authors were unable to reconstruct the cracks observed in practical operation in anodically protected heat exchanger pipes of stainless austenitic steel. (orig./MM). 5 refs., 2 tabs., 71 figs.

1990-09-20

119

Heating and hot water: the installations; Chauffage et eau chaude: les installations  

Energy Technology Data Exchange (ETDEWEB)

This book brings recommendations and information on the choice and the operating of heating systems and domestic hot water production in order to better choose the house, to better use the heating and to preserve the environment. General notions on the different heating systems and their operating on the renewable energies used and the heating emitters offer advices for the purchase of a house. (A.L.B.)

2005-07-01

120

Steady-state thermal and hydraulic calculation of steam generator considering heat transfer tube lengths  

Energy Technology Data Exchange (ETDEWEB)

The effect of heat transfer is described from heat exchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heat exchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heat exchange tubes neqlecting the changes of physical properties of water along the heat exchange tubes, will yield sufficiently accurate results.

1982-10-01

121

Steady-state thermal and hydraulic calculation of steam generator considering heat transfer tube lengths  

International Nuclear Information System (INIS)

The effect of heat transfer is described from heat exchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heat exchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heat exchange tubes neqlecting the changes of physical properties of water along the heat exchange tubes, will yield sufficiently accurate results. (author).

1982-01-01

122

Probability of failure in BWR reactor coolant piping: Guillotine break indirectly induced by earthquakes  

Energy Technology Data Exchange (ETDEWEB)

The requirements to design nuclear power plants for the effects of an instantaneous double-ended guillotine break (DEGB) of the reactor coolant piping have led to excessive design costs, interference with normal plant operation and maintenance, and unnecessary radiation exposure of plant maintenance personnel. This report describes an aspect of the NRC/Lawrence Livermore National laboratory-sponsored research program aimed at investigating whether the probability of DEGB in Reactor Coolant Loop Piping of nuclear power plants is acceptably small such that the requirements to design for the DEGB effects (e.g., provision of pipe whip restraints) may be removed. This study estimates the probability of indirect DEGB in Reactor Coolant piping as a consequence of seismic-induced structural failures within the containment of the GE supplied boiling water reactor at the Brunswick nuclear ...

1986-12-01

123

Loaded Transducer Fpr Downhole Drilling Component  

Energy Technology Data Exchange (ETDEWEB)

A robust transmission element for transmitting information between downhole tools, such as sections of drill pipe, in the presence of hostile environmental conditions, such as heat, dirt, rocks, mud, fluids, lubricants, and the like. The transmission element maintains reliable connectivity between transmission elements, thereby providing an uninterrupted flow of information between drill string components. A transmission element is mounted within a recess proximate a mating surface of a downhole drilling component, such as a section of drill pipe. To close gaps present between transmission elements, transmission elements may be biased with a "spring force," urging them closer together.

2005-07-05

124

Probabilistic leak before break evaluation of straight pipes of primary heat transport piping of Tarapur-3 and 4 NPP  

International Nuclear Information System (INIS)

Piping systems transporting high-pressure fluid will release a large amount of energy, leading to whipping of the broken pipe as well as impingement of the ejecting fluids on adjacent structures if they fracture unstably. Postulation of such an event in design of piping systems in nuclear power plants often requires various counter measures such as installation of pipe whip restraints or jet impingement shields to prevent such damage. One of the approaches to justify exclusion of unstable fracture from the design conditions is leak-before-break (LBB) analysis. In order to demonstrate LBB behavior, it is necessary to prove that in the presence of a part-through wall flaw in the pipe, this flaw will not grow through the wall under fatigue loading and is stable (level 2 LBB) and that the leak of fluid through the penetration is detected by leak detection systems before unstable ...

2006-11-01

125

Rural residential application of geothermal heat pump. Progress report  

Energy Technology Data Exchange (ETDEWEB)

The installation and performance of a water source heat pump in Minnesota are discussed. The operating cost was found to be higher than expected. (MHR)

1981-07-20

126

Users' guide on socket heat fusion joining of polyethylene gas pipes. Volume 1. Topical report, September 1989-September 1990  

Energy Technology Data Exchange (ETDEWEB)

The integrity of a pipeline system is determined by its weakest links which may be the joints. Heat fusion is the most common method for joining gas distribution polyethylene (PE) piping. There are procedural, thermal, and mechanical aspects of making fusion joints. Acceptable procedural aspects, such as heater calibration and cleanliness, can be assured by rigorous training and certification of the operators. Thermal and mechanical aspects consist of specifying joining conditions such as the heater temperature, heating time, and joining pressure. In the absence of procedural errors, the strength of a fusion joint should depend on the pipe material, pipe dimensions, and the thermal and mechanical joining conditions. Socket heat fusion was studied both experimentally and analytically to determine how the strength of the joint varied with the conditions under ...

1991-03-01

127

Technical reference on socket heat fusion joining of polyethylene gas pipes. Volume 2. Topical Report, September 1989-September 1990  

Energy Technology Data Exchange (ETDEWEB)

The integrity of a pipeline system is determined by its weakest links which may be the joints. Heat fusion is the most common method for joining gas distribution polyethylene (PE) piping. There are procedural, thermal, and mechanical aspects of making fusion joints. Acceptable procedural aspects, such as heater calibration and cleanliness, can be assured by rigorous training and certification of the operators. Thermal and mechanical aspects consist of specifying joining conditions such as the heater temperature, heating time, and joining pressure. In the absence of procedural errors, the strength of a fusion joint should depend on the pipe material, pipe dimensions, and the thermal and mechanical joining conditions. Socket heat fusion was studied both experimentally and analytically to determine how the strength of the joint varied with the conditions under ...

1991-03-01

128

Full-scale model of cooling and heating system for JT-60 vacuum vessel  

Science.gov (United States)

A full-scale model of a rigid sectorial ring and a set of bellows which was covered with a temperature control layer and a coolant supply equipment was constructed to verify the adequacy of the heating and cooling system designed for JT-60. To cool and heat it effectively and to decrease the temperature differences among the various parts in the vacuum vessel, heater units and cooling pipes were located on the surface of the ring. The temperature control layer is to heat the vessel to 500/degree/sub //C within 70 hours and to maintain it at the temperature for 48 hours for simulating the state of bakeout. Subsequently the vessel is cooled down within about the same time as in heating. Prior to the series of tests, numerical analyses were performed to predict the cooling and heating efficiencies on the model and to examine the method of the temperature ...

1981-01-01

129

Effect of Cr content, hardness and micro structure on flow-accelerated corrosion in carbon steel pipes. Examination of replaced carbon steel pipes  

International Nuclear Information System (INIS)

68 replaced carbon steel piping in secondary system of pressurized water reactor (PWR) has been investigated by visual examination for checking thinning conditions. It is well known that the flow-accelerated corrosion (FAC) was inhibited by traces of Cr in steel. Therefore, the chemical compositions of those steels have been measured. In addition, the micro structure and hardness of those steels have been investigated. And the relationship between those material variables and FAC rate was considered. As the results, (1) The Cr contents in those steels were below 0.1 wt% except one sample. Minute quantities of chromium increase the resistance against FAC. But the water velocity was thought to be the dominant factor rather than chemical composition in steel, at least such as below 0.1%Cr. (2) Hardness of all piping has been satisfied the specifications of each materials. The hardness of steels was not ...

2008-10-01

130

Lauric and palmitic acids eutectic mixture as latent heat storage material for low temperature heating applications  

Energy Technology Data Exchange (ETDEWEB)

Palmitic acid (PA, 59.8 {sup o}C) and lauric acid (LA, 42.6 {sup o}C) are phase change materials (PCM) having quite high melting temperatures which can limit their use in low temperature solar applications such as solar space heating and greenhouse heating. However, their melting temperatures can be tailored to appropriate value by preparing a eutectic mixture of the lauric and the palmitic acids. In the present study, the thermal analysis based on differential scanning calorimetry (DSC) technique shows that the mixture of 69.0 wt% LA and 31 wt% PA forms a eutectic mixture having melting temperature of 35.2 {sup o}C and the latent heat of fusion of 166.3 J g{sup -1}. This study also considers the experimental determination of the thermal characteristics of the eutectic mixture during the heat charging and discharging processes. Radial and axial temperature distribution, heat ...

2005-04-01

131

Evaluation of heat exchange rate of GHE in geothermal heat pump systems  

Energy Technology Data Exchange (ETDEWEB)

Total thermal resistance of ground heat exchanger (GHE) is comprised of that of the soil and inside the borehole. The thermal resistance of soil can be calculated using the linear source theory and cylindrical source theory, while that inside the borehole is more complicated due to the integrated resistance of fluid convection, and the conduction through pipe and grout. Present study evaluates heat exchange rate per depth of GHE by calculating the total thermal resistance, and compares different methods to analyze their similarities and differences for engineering applications. The effects of seven separate factors, running time, shank spacing, depth of borehole, velocity in the pipe, thermal conductivity of grout, inlet temperature and soil type, on the thermal resistance and heat exchange rate are analyzed. Experimental data from several real geothermal heat ...

2009-12-15

132

Application of a 3-beam #gamma# densitometer to two-phase flow regime and density measurements  

International Nuclear Information System (INIS)

A method of using gamma radiation to determine the density and phase distribution in two-phase flows in pipes is described. Three collimated beams of radiation that pass through a pipe cross-section at different radial positions are used. A theory and computer program used to relate the measured attenuation of these beams to a three-parameter model of the phase distribution and to the average density and void fraction are discussed. Data obtained during both static and dynamic verification experiments using Lucite inserts are presented, as well as the results of several tests done in high pressure, steam-water flows.

1976-08-11

133

Oil and Natural Gas Technology: Development of Next Generation Multiphase Pipe Flow Prediction Tools. Final Report.  

Science.gov (United States)

The developments of fields in deep waters (5000 ft and more) is a common occurrence. It is inevitable that production systems will operate under multiphase flow conditions (simultaneous flow of gas-oil-and water possibly along with sand, hydrates, and wax...

2008-01-01

134

Development of Next Generation Multiphase Pipe Flow Prediction Tools. Semi-Annual Technical Report. Reporting Period: June 2006 through November 2006.  

Science.gov (United States)

The developments of oil and gas fields in deep waters (5000 ft and more) will become more common in the future. It is inevitable that production systems will operate under multiphase flow conditions (simultaneous flow of gas-oiland water possibly along wi...

2007-01-01

135

Chemical reactions in a solar furnace 2: Direct heating of a vertical reactor in an insulated receiver. Experiments and computer simulations  

Energy Technology Data Exchange (ETDEWEB)

The performance of a solar chemical heat pipe was studied using CO{sub 2}reforming of methane as the endothermic reaction. A directly heated vertical reactor, packed with a rhodium catalyst was used. The solar tests were carried out in the Schaeffer solar furnace of the Weizmann Institute of Science. The power absorbed was up to 6.3 KW, the maximal flow rates of the gases reached 11,000 1/h, and the methane conversions reached 85%. A computer model was developed to simulate the process. Agreement of the calculations with the experimental results was quite satisfactory.

1992-01-01

136

Effect of water chemistry improvement on flow accelerated corrosion in light-water nuclear reactor  

International Nuclear Information System (INIS)

Flow Accelerated Corrosion (FAC) of Carbon Steel (CS) piping has been one of main issues in Light-Water Nuclear Reactor (LWRs). Wall thinning of CS piping due to FAC increases potential risk of pipe rupture and cost for inspection and replacement of damaged pipes. In particular, corrosion products generated by FAC of CS piping brought steam generator (SG) tube corrosion and degradation of thermal performance, when it intruded and accumulated in secondary side of PWR. To preserve SG integrity by suppressing the corrosion of CS, High-AVT chemistry (Feedwater pH9.8#+-#0.2) has been adopted to Tsuruga-2 (1160 MWe PWR, commercial operation in 1987) in July 2005 instead of conventional Low-AVT chemistry (Feedwater pH 9.3). By the High-AVT adoption, the accumulation rate of iron in SG was reduced to one-quarter of that under conventional Low-AVT. As a result, a ...

2009-10-01

137

Recovering heat from the cupola stack  

Energy Technology Data Exchange (ETDEWEB)

A brief survey is given of some ways in which heat, which would normally be lost from a cupola furnace, is being recovered, either as hot water, steam, or electricity. Examples are provided of heat-recovery systems in Germany, Italy, and America. (author).

1986-01-01

138

Simplified solar fraction estimation for space and water heating at dod installations. appendix c. water heating nomographs. Final report  

Energy Technology Data Exchange (ETDEWEB)

This report contains a set of nomographs which can be used to estimate the average annual solar fraction for solar space and water heating at a large number of DOD facilities. The solar fraction estimated from the nomograph is in close agreement with F-Chart 3.0 and allows for variation of the following parameters: annual load, collector area, collector transmittance-absorptance coefficient, and collector overall loss coefficient.

1982-09-01

139

Geothermal heat pump  

Energy Technology Data Exchange (ETDEWEB)

Ground water ranging in temperature from only 38/sup 0/ to 140/sup 0/F can supply a considerable amount of heat energy when couple with a geothermal or ground-water heat pump. The heat pump's method of operation is examined as well as its performance characteristics. (MHR)

1982-12-01

140

The onset conditions of enhancement of ice accumulation associated with heat-conducting plates located perpendicularly to heat-transfer surfaces; Part 1: Analysis for still water  

Energy Technology Data Exchange (ETDEWEB)

An analytical study of the ice-formation process associated with heat-conducting plates located perpendicularly to isothermally heated and cooled surfaces with some clearance is presented. It is proposed that the onset conditions, which describe whether the ice-volume fraction in a steady state is greater than or less than that without heat-conducting plates, are defined by the dimensionless distances between the heated/cooled walls and the heat-conducting plates. It is shown that the onset conditions are dependent on the pitch and the thickness of the heat-conducting plates and are less dependent on the thermal conductivity of the plates.

1994-07-01

141

Recovery of Water from Boiler Flue Gas  

Energy Technology Data Exchange (ETDEWEB)

This project dealt with use of condensing heat exchangers to recover water vapor from flue gas at coal-fired power plants. Pilot-scale heat transfer tests were performed to determine the relationship between flue gas moisture concentration, heat exchanger design and operating conditions, and water vapor condensation rate. The tests also determined the extent to which the condensation processes for water and acid vapors in flue gas can be made to occur separately in different heat transfer sections. The results showed flue gas water vapor condensed in the low temperature region of the heat exchanger system, with water capture efficiencies depending strongly on flue gas moisture content, cooling water inlet temperature, heat exchanger ...

2008-09-30

142

FY1998 research report on the basic research on geothermal district heating in Kamchatka, Russia; 1998 nendo Roshia Renpo Kamchatka shu ni okeru chinetsu riyo ni yoru chiiki danbo ni kansuru kiso chosa hokokusho  

Energy Technology Data Exchange (ETDEWEB)

Petropavlovsk-Kamchatky (P-K) city in Kamchatka, Russia is operating hot-water district heating using heavy oil boilers and waste hot water of thermal power plants as heat sources. Feasibility study was made on district heating using natural geothermal hot water and/or geothermal heat pump systems as heat sources of hot water supply for reduction of greenhouse effect gas emission. Among 3 areas including geothermal hot water, use of hot water in K area was impossible because of lower temperature and less spring water. Use of hot water in P and UP areas was impossible as primary hot water because of temperature drop to 64 degrees C during hot water supply toward P-K city. The ...

1999-05-01

143

WATER SUPPLY ANALYSIS  

Energy Technology Data Exchange (ETDEWEB)

This analysis defines and evaluates the surface water supply system from the existing J-13 well to the North Portal. This system includes the pipe running from J-13 to a proposed Booster Pump Station at the intersection of H Road and the North Portal access road. Contained herein is an analysis of the proposed Booster Pump Station with a brief description of the system that could be installed to the South Portal and the optional shaft. The tanks that supply the water to the North Portal are sized, and the supply system to the North Portal facilities and up to Topopah Spring North Ramp is defined.

1996-02-06

144

Trace metals in tap water from Tehran, Iran  

Energy Technology Data Exchange (ETDEWEB)

A total of 272 tap water samples were collected from 68 homes throughout the city of Tehran. Analysis for cadmium, zinc, lead, copper, arsenic, iron and manganese showed some accumulation of these metals in household piping overnight. However, the concentration of all metals was in the parts per billion (ug/l) range and well below international standards. Heavy metals in Tehran's drinking water therefore, do not pose a significant acute health hazard. 19 references, 2 tables.

1986-01-01

145

On the water-chemical regime in steam generators at NPP  

British Library Electronic Table of Contents (United Kingdom)

The effect of the water-chemical regime (WCR) on damage sustained by heating surfaces of steam generators at NPP is analyzed. It is indicated that phosphate treatment with minimal excesses of phosphates in the steamgenerator water is the most optimal method of managing the WCR regime of horizontal steam generators.

2006-01-01

146

Heat-transfer analysis of the plum brook reactor - NASA Technical ...  

Science.gov (United States)

average bulk water temper ature rise, OF bulk water temperature at elevation z, OF bulk water temperature in channels 0 and 1, O F film temperature, OF ...

147

Condensation heat transfer in a steam-water stratified flow  

Energy Technology Data Exchange (ETDEWEB)

Fundamental phenomena of condensation heat transfer at a steam-water interface have been studied related to the thermo-hydrodynamics of the emergency core cooling system for light water reactors. In this study temperature fluctuations near the interface and in the liquid phase were measured using fine thermocouples for a saturated steam-subcooled water co-current stratified two-phase flow in a nearly horizontal rectangular channel, and heat transfer coefficients were determined experimentally. The values of the condensation heat transfer coefficients in this experiment are from 6 to 40 kW/m{sup 2}K. In the regions of high Reynolds numbers, as the steam Reynolds numbers become larger, the average interfacial heat transfer coefficients tend to increase. The corelations of Nusselt numbers were obtained from the heat ...

1999-07-01

148

Condensation heat transfer in a steam-water stratified flow  

International Nuclear Information System (INIS)

Fundamental phenomena of condensation heat transfer at a steam-water interface have been studied related to the thermo-hydrodynamics of the emergency core cooling system for light water reactors. In this study temperature fluctuations near the interface and in the liquid phase were measured using fine thermocouples for a saturated steam-subcooled water co-current stratified two-phase flow in a nearly horizontal rectangular channel, and heat transfer coefficients were determined experimentally. The values of the condensation heat transfer coefficients in this experiment are from 6 to 40 kW/m"2K. In the regions of high Reynolds numbers, as the steam Reynolds numbers become larger, the average interfacial heat transfer coefficients tend to increase. The corelations of Nusselt numbers were obtained from the heat transfer ...

1999-04-19

149

Boiling heat transfer of subcooled water in a horizontal rectangular channel. Observation of MEB and MEB generation; Kukeikan ryuronai no subcool futto netsu dentatsu. Kiho bisaika futto no kansatsu to hassei joken  

Energy Technology Data Exchange (ETDEWEB)

Forced convection boiling of subcooled water was performed in a horizontal rectangular channel with heated surface on the bottom. The experiment was conducted for heating surfaces, 10 mm, 20 mm and 40mm in length. Microbubble Emission Boiling, MEB, was observed in subcooled transition boiling and easy to be generated for the shorter heating surfaces. In higher flow velocity of subcooled water, MEB was generated at even lower subcooling. Stormy MEB was observed at both the higher subcooling and the higher flow velocity of water. In the stormy MEB, the heat flux rose up rapidly above CHF (Critical Heat Flux) with larger acoustic noise and vibration. (author)

1999-09-25

150

Behaviour of nonlinear supports on a PWR coolant system during a postulated LOCA. Pt. 1; Effect of modelling methods  

Energy Technology Data Exchange (ETDEWEB)

A 4-loop Pressurised Water Reactor (PWR) primary coolant system has been analysed for the postulated Loss of Coolant Accident (LOCA) event in order to derive peak dynamic loads for qualifying the design of equipment supports and pipe whip restraints. Pipe whip restraints as well as pipe and equipment supports are nonlinear by nature because of the presence of gaps and the different directional stiffnesses arising from snubber, steelwork and geometric and material interaction at the concrete to steel embedment. The different structural idealisations for the supports and restraints have an influence on the dynamic response of the structure. In the first of the two part paper a range of idealisation models for the Steam Generator and Reactor Coolant Pump vertical columns ranging from elastic stiffnesses to bilinear stiffnesses with or without preload were examined. Due to both structural and loading ...

1993-07-01

151

Improvement of the PGV-1000 steam generator in-vessel components  

International Nuclear Information System (INIS)

Results of calculational investigations into circulation of water and steam-and-water mixture in the PGV-1000 steam generator heat exchanger bundle used at NPPs with the WWER-1000 reactors, are considered. Model of water circulation in horizontal steam generator with submerged heating surface under conditions of steam generation irregularity along the heat transfer tubes is made. On the basis of the obtained data the assumption is made about water essential overflows from the hot collector zone into the cold one. Overflow rate over the upper line of the heat transfer tubes may constitute 0.7 m/s. The conclusion is made about the necessity to set up the vertical barrier which divides hot and cold sections of heat transfer tubes and helps to avoid water transverse overflows.

1988-01-01

152

Method of feeding a coolant into a reactor  

International Nuclear Information System (INIS)

Object: To suppress a quantity of impurities in a coolant fed into a reactor vessel. Structure: The concentration of oxygen in a coolant flowing from a condensation desalting instrument into a feed and condensation piping is measured by an oxygen-concentration detector to feed its signal to an adjusting instrument. A degree of opening of an oxygen flow control valve to maintain the concentration of oxygen in the cooling water flowing within the pipe in the range from about 10 to about 200 ppb. Also, the concentration of oxygen in the cooling water fed to the desalting instrument is maintained at a level less than 2 ppb. Thereby, the total amount of iron flown into the vessel can be suppressed to a fine amount such as less than about 1 ppb. (Kawakami, Y.).

153

Free and forced convective cooling of pipe-type electric cables. Volume 2: electrohycrodynamic pumping. Final report  

Energy Technology Data Exchange (ETDEWEB)

A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one, reported in Volume 1, dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of entrance and exit chambers ...

1981-05-01

154

Free and forced convective cooling of pipe-type electric cables. Volume 1: forced cooling of cables. Final report  

Energy Technology Data Exchange (ETDEWEB)

A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one reported in this volume dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of entrance and exit ...

1981-05-01

155

Fracture behavior of heat-affected zone in low alloy steels  

International Nuclear Information System (INIS)

Past elastic-plastic fracture studies for leak-before-break (LBB) assessment of low alloy steel pipings have been focused mostly on the behavior of base metals and their weld metals. In contrast, the heat-affected zone (HAZ) of a welded pipe has not been studied in detail primarily because the size of the HAZ is too small to make specimens for mechanical properties measurements. In this study, microstructural analyses, microhardness tests, tensile tests and J-R tests have been conducted as a function of distance from a fusion line and temperature for HAZ materials of SA106Gr.C low alloy piping steels. For the ferrite-pearlite steels such as SA106Gr.C, the HAZ specimens showed a higher yield strength and fracture toughness compared with those of its base metal. These characteristics, despite of grain coarsening, can be explained by cleaner microstructures of HAZ materials with a finer morphology of ...

2001-11-01

156

A study of binary mixture boiling: boiling site density and subcooled heat transfer  

Energy Technology Data Exchange (ETDEWEB)

(Boiling site densities and heat-transfer coefficients have been measured for ethanol-water and ethanol-benzene mixtures at 1.01 bar for a heated vertical brass disk. A strong effect of composition on the boiling site density was observed, which was attributed to the nature of the activation of the boiling surface and mass diffusion effects. The boiling heat-transfer coefficient was found to decrease with increasin subcooling, but for the mixtures at a given level of subcooling the decrease was less than that for the single components and azeotropic mixtures.) The heat-transfer coefficient at a given heat flux was seen to be quite insensitive to the very large increase in boiling site density in comparing the pure water and the ethanol-water azeotrope results, leading one to question pool boiling models that predict ...

1985-05-01

157

Thermal and heat transfer characteristics in a latent heat storage system using lauric acid  

Energy Technology Data Exchange (ETDEWEB)

The thermal and heat transfer characteristics of lauric acid during the melting and solidification processes were determined experimentally in a vertical double pipe energy storage system. In this study, three important subjects were addressed. The first one is temperature distributions and temporal temperature variations in the radial and axial distances in the phase change material (PCM) during phase change processes. The second one is the thermal characteristics of the lauric acid, which include total melting and total solidification times, the nature of heat transfer in melted and solidified PCM and the effect of Reynolds and Stefan numbers as inlet heat transfer fluid (HTF) conditions on the phase transition parameters. The final one is to calculate the heat transfer coefficient and the heat flow rate and also discuss the role of Reynolds and Stefan numbers ...

2002-12-01

159

Steam-water two-phase flow in large diameter vertical piping at high pressures and temperatures  

Energy Technology Data Exchange (ETDEWEB)

No information on steam/water two-phase flow behavior in large diameter pipes (10 inch or larger) at elevated pressures is available in the open literature. However, there are many applications, in the nuclear, chemical and petroleum industries among others where two-phase flows in large diameter pipes at elevated pressures and temperatures are encountered routinely or under accident scenarios. Experimental data on steam-water two-phase flow in a large diameter (20 inch, 50.08 cm I.D.) vertical pipe at elevated pressures and temperatures (2.8 MPa/230 C--6.4 MPa/280 C) have been obtained. Void fraction, two-phase mass flux, phase and velocity distributions as well as pressure drop along the test pipe have been measured using the Ontario Hydro Technologies (OHT) Pump Test Loop. The void fraction distributions were found to be axially symmetric and nearly flat over ...

1996-08-01

160

Steam-water two-phase flow in large diameter vertical piping at high pressures and temperatures  

International Nuclear Information System (INIS)

No information on steam/water two-phase flow behavior in large diameter pipes (10 inch or larger) at elevated pressures is available in the open literature. However, there are many applications, in the nuclear, chemical and petroleum industries among others where two-phase flows in large diameter pipes at elevated pressures and temperatures are encountered routinely or under accident scenarios. Experimental data on steam-water two-phase flow in a large diameter (20 inch, 50.08 cm I.D.) vertical pipe at elevated pressures and temperatures (2.8 MPa/230 C--6.4 MPa/280 C) have been obtained. Void fraction, two-phase mass flux, phase and velocity distributions as well as pressure drop along the test pipe have been measured using the Ontario Hydro Technologies (OHT) Pump Test Loop. The void fraction distributions were found to be axially symmetric and nearly flat over ...

1996-03-10

161

Low Frequency Phased Array Techniques for Crack Detection in Cast Austenitic Piping Welds: A Feasibility Study  

Energy Technology Data Exchange (ETDEWEB)

Studies conducted at the Pacific Northwest National Laboratory (PNNL) in Richland, Washington have focused on developing and evaluating the reliability of nondestructive testing (NDT) approaches for coarse-grained stainless steel reactor components. The objective of this work is to provide information to the United States Nuclear Regulatory Commission (NRC) on the utility, effectiveness and limitation of NDT techniques as related to inservice testing of primary system piping components in pressurized water reactors. We examined cast stainless steel pipe specimens containing thermal and mechanical fatigue cracks located close to the weld roots and having inner and outer diameter surface geometrical conditions that simulate several water reactor primary piping configurations. In addition, segments of vintage centrifugally cast piping were examined to characterize ...

2007-01-01

162

A mathematical model for simulating shallow solar ponds for treatment of industrial wastewater  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a mathematical model to analyze the solar evaporation in a shallow pond in steady state, when the inlet flow rate, concentration, surface area and solar radiation are given. The simultaneous heat and mass transfer mechanisms are considered for quantifying the amount of evaporated water to the atmosphere and the actual absorbed heat by wastewater is calculated to obtain the bottom temperature of water pond. The heat losses to air by radiation and convection mechanisms are considered and the heat transmission across the water film is evaluated by the forced convection mechanism. 6 refs., 5 figs., 1 tab.

1996-12-31

163

Pumping manual/7th edition  

Energy Technology Data Exchange (ETDEWEB)

This book includes the latest developments and covers pump performance, selection and operations, materials, seals and packings, effective fluid characteristics, filtration, piping systems, economics, valves, instrumentation, automatic controls, power transmission equipment, pump and pipeline heating, and more. An extensive data section contains formulas, charts, symbols, nomographs, and standard specification documents.

1984-01-01

164

AquaMagna Water Conditioner and Descaler  

Wastenet

...AquaMagna Water Conditioner and Descaler OCETA Environmental Technology & Business Profiles AQUAMAGNA WATER CONDITIONER AND DESCALER CAT. #03-018 CONTACT: Magna-Tek ...removal high-strength ceramic magnet no energy input The AquaMagna Water Conditioner and Descaler is a non-chemical method of water treatment. The technology uses ... Figure 1: The AquaMagna Water Conditioner and Descaler PROCESS/ PRODUCT APPLICATION: hard water domestic water process water reverse osmosis heat exchangers cooling ... For once-through or recirculating heating or cooling equipment, the AquaMagna descaler improves thermal efficiencies and reduces downtime. Figure 2 illustrates a cross-section ...

165

Heat rejection system  

Energy Technology Data Exchange (ETDEWEB)

A cooling system for rejecting waste heat consists of a cooling tower incorporating a plurality of coolant tubes provided with cooling fins and each having a plurality of cooling channels therein, means for directing a heat exchange fluid from the power plant through less than the total number of cooling channels to cool the heat exchange fluid under normal ambient temperature conditions, means for directing water through the remaining cooling channels whenever the ambient temperature rises above the temperature at which dry cooling of the heat exchange fluid is sufficient and means for cooling the water. 5 figs.

1980-01-22

166

Simplified solar fraction estimation for space and water heating at DOD installations. appendix b. space heating nomographs. Final report  

Energy Technology Data Exchange (ETDEWEB)

A set of nomographs is presented which can be used to estimate the average annual solar fraction for solar space and water heating at a large number of DOD facilities. The solar fraction estimated from the nomograph is in close agreement with F-Chart 3.0 and allows for variation of the following parameters: annual load, collector area, collector transmittance-absorptance coefficient, and collector overall loss coefficient.

1982-09-01

167

Rural residential application of geothermal heat pump. Final grant report  

Energy Technology Data Exchange (ETDEWEB)

A project to demonstrate residential heating and cooling with a well-water source heat pump is documented. The system is schematically illustrated and described, and project experience is discussed. The system is capable of using source water as cool as 40/sup 0/F. Project expenses are accounted for. (LEW)

1982-07-30

168

Effect of ultrasonic waves on boiling heat transfer. 2  

International Nuclear Information System (INIS)

This report focuses on a better understanding of the physical phenomenon related to the enhancement of boiling and non-boiling heat transfer by applying ultrasonic waves. Experimental results obtained both in a pool of water and in a vertically upward water flow proved clearly that macroscopic acoustic steam induced by ultrasonics is a major contribution to heat transfer augmentation. (author).

1993-05-01

169

Effect of ultrasonic waves on boiling heat transfer  

Energy Technology Data Exchange (ETDEWEB)

This report focuses on a better understanding of the physical phenomenon related to the enhancement of boiling and non-boiling heat transfer by applying ultrasonic waves. Experimental results obtained both in a pool of water and in a vertically upward water flow proved clearly that macroscopic acoustic stream induced by ultrasonics is a major contribution to heat transfer augmentation. (author).

1993-07-01

170

Verification of the CFD code FLUENT by post test calculation of the ROCOM experiment T665521; Validierung des CFD codes FLUENT anhand der Nachrechnung des ROCOM Experimentes T665521  

Energy Technology Data Exchange (ETDEWEB)

During the last years one focus of German PWR safety analysis was boron dilution events with the potential of reactivity transients. Coolant with a low boron concentration could be collected in localized areas of the reactor coolant system e.g. by separation of borated reactor coolant into highly concentrated and diluted fractions (inherent dilution) which can occur during reflux- condenser heat transfer after a small break loss of coolant accident with a limited availability of the emergency core cooling systems. The TUeV NORD SysTec was charged by German supervisory authorities with the assessment of the safety analyses of boron dilution events presented by the utilities. These analyses are based on the simulation of boron dilution and transport processes in conjunction with a number of dedicated experiments. The analyses shall demonstrate that boron dilution events cannot lead to recriticality of the core. Hence the boron concentration at the core inlet has to ...

2005-05-01

171

Verification of the CFD code FLUENT by post test calculation of the ROCOM experiment T665521  

International Nuclear Information System (INIS)

During the last years one focus of German PWR safety analysis was boron dilution events with the potential of reactivity transients. Coolant with a low boron concentration could be collected in localized areas of the reactor coolant system e.g. by separation of borated reactor coolant into highly concentrated and diluted fractions (inherent dilution) which can occur during reflux- condenser heat transfer after a small break loss of coolant accident with a limited availability of the emergency core cooling systems. The TUeV NORD SysTec was charged by German supervisory authorities with the assessment of the safety analyses of boron dilution events presented by the utilities. These analyses are based on the simulation of boron dilution and transport processes in conjunction with a number of dedicated experiments. The analyses shall demonstrate that boron dilution events cannot lead to recriticality of the core. Hence the boron concentration at the core inlet has to ...

2005-05-01

172

The significance of local hard zones on the outside of pipeline girth welds: Further studies  

Energy Technology Data Exchange (ETDEWEB)

The NACE MR-01-75 standard imposes a restriction of 22HRC maximum for regions of a pipeline girth weld that are not in direct contact with H[sub 2]S containing environments. TWI have demonstrated in an earlier project for the Pipeline Research Committee (PRC) that it may be permissible to relax this maximum hardness requirement. Such a relaxation, which already exists in the BS4515: 1984 standard, offers potential benefits when applied to the capping pass and heat affected zone of a pipeline girth weld. This report presents additional data to supplement that obtained in a previous PRC project conducted at TWI. Further pipe materials with differing pipe wall thicknesses have been welded, exposed to an internal H[sub 2]S containing environment and examined for sulphide stress corrosion cracking.

1991-10-01

173

Electrohydrodynamic pumping in cable pipes. Final report  

Energy Technology Data Exchange (ETDEWEB)

Many oil-insulated electric power cables are limited by heat buildup caused in part by the low thermal conductivity of the oil. Circulation of the oil is known to reduce the cable temperature, but can lead to excessive pressure buildup on long cables when using conventional pumping methods. An alternate pumping method using distributed electric fields to avoid this pressure buildup is described. Electrohydrodynamic (EHD) pumping was studied both theoretically and experimentally for possible application in underground cable cooling. Theoretical studies included both analytical and finite-element analysis of the flow patterns driven by travelling electric fields. Experimentally, flow rates in a cable-pipe model were measured under a wide variety of operating conditions. Theory and experiment are in agreement for velocities below 10 cm/s, but higher velocities could not be reached in the experiment, due to increased electroconvection and, ...

1983-02-01

174

Necessity for usage of geothermal heat pump  

International Nuclear Information System (INIS)

Every day we are witnesses of constantly rapid increase of consumption of Electric energy in R. of Macedonia as so as in the other countries in all the world. This rapid increase of consumption of Electric energy independent of a lot of electrical units, which are applying in human life like: homes, administration and publication objects, as well as in industry. All of this conditions make us to thinking how is possible more rational consumption of electric energy in all areas in human life. One of the possible manners to reduce the consumption of electrical energy for heating and cooling is to use geothermal heat pumps. In this paper will be proposed geothermal heat pump, which is going to use the heat of earth by vertical and horizontal cupper pipe heat exchanger with data from-GHP (Geothermal Heat Pump) NORDIC, factory in Canada. Also, it ...

2004-10-07

175

Fundamental study on the convective heat transfer augmentation of a wavy type heat exchanger  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the study is to investigate the heat transfer augmentation method for a wavy channel type heat exchanger. Experimental studies were carried out, by installation of flow guide-plates with simple structure, to clarify the effects on the augmentation whether the effects are brought by the flow acceleration or by the increase of intensity of turbulence due to the flow seperation, and to determine optimum shape of flow guide-plates. The shape and dimensions of the experimental apparatus are as follows; channel width H of 30 mm, rectangular section with breadth of 300 mm, wavy duct with a bend angle of 60/sup 0/ and straight pipe of 2H length. Air stream was flowed through the duct with Reynolds number of 1.7 x 10/sup 4/ only. As the results, following conclusions were obtained. (1) Wavy duct with large bend angle and without inserting flow guide-plates could not be expected large effects on the ...

1988-06-25

176

Experimental study and performance evaluation of convective heat transfer augmentation with coiled wire inserts  

Energy Technology Data Exchange (ETDEWEB)

An experimental study of forced convection heat transfer at the inner tube wall of a double pipe heat exchanger with coiled wire inserts as heat transfer augmentation devices was performed over a turbulent flow region. The test results from twelve augmented tubes with inserts of different combinations of wire diameters (0.813, 1.016 and 1.575 mm) and pitches (2.82, 3.63, 5.08 and 8.47 mm) indicate that the turbulence promoters studied improve heat transfer by a factor of 1.4 to 2.24 compared with a smooth tube, although at a cost of 10-30 times increase in friction factor. A formula for presenting dimensionless exergy losses in a tubular heat exchanger is derived first and then the thermohydrodynamic optimum instead of economic optimum is found by minimizing the exergy losses in the system. From the heat transfer improvement number defined, ...

1992-12-01

177

Dynamic load in suppression pool during BWR main steam safety relief valve actuation  

International Nuclear Information System (INIS)

BWRs are so designed that the exhaust steam from main steam safety relief valves is led to pressure suppression pools, and the steam is condensed in pool water, but at this time, dynamic load seems to arise in the pool water. In Tokai No. 2 Power Station, a Mark-2 containment vessel was adopted to improve the reliability as much as possible and to obtain the design with margin. In this report, the result of actual machine test in Tokai No. 2 Power Station and the method of reducing the load are described. When a relief valve works, the discharge of water in exhaust pipes into a suppression pool, the exhaust of air in exhaust pipes and repeated expansion and contraction of bubbles in pool water, and the exhaust of steam and condensation occur. As for the construction of the suppression pool in Tokai No. 2 Power Station, cross-shaped quencher and the structure ...

1979-01-01

178

Thermogalvanic effects on the pitting corrosion of water-cooled heat exchangers  

Energy Technology Data Exchange (ETDEWEB)

Thermogalvanic corrosion of St3 steel in a temperature range from 25 to 50{degrees}C with a 3.84{degrees}C/cm gradient was studied in a neutral media flow. It is shown that the thermogalvanic effect on the pitting corrosion of water-cooled heat exchangers is decisive but dual. Depending on the composition of the cooling medium, thermogalvanic corrosion may either enhance (0.5 M NaCl) or inhibit (tap water) pitting corrosion.

1995-05-01

179

Device for increasing the decontamination factor in the treatment of radioactive waste water. Vorrichtung zur Erhoehung der Dekontaminationsfaktoren bei der Aufbereitung radioaktiver Abwaesser  

Energy Technology Data Exchange (ETDEWEB)

In the well-known devices for increasing the decontamination factor in the treatment of radioactive waste water by evaporation, which consist of narrowing devices with evaporator sump and condenser, droplets of liquid and solid particles are carried over from the breeder space, which are radioactive and therefore make the decontamination factor worse. Better results are obtained if one places a fibre bed filter between the evaporator sump and the condenser, preferably in a horizontal connecting pipe between the evaporator sump and the condenser.

1982-06-09

180

Study on the transient piping vibration of power plant. Secondary piping system of Wolsung 1 unit.  

Science.gov (United States)

In order to maintain a safe operation and availability of generating facilities, qualitative and quantitative assessment of piping vibration was performed vibration sources and damages of piping support was identified on the second piping system of Wolsun...

1996-01-01

181

System for cooling primary gas coolers using return water stabilized by means of ammonium sulfate  

Energy Technology Data Exchange (ETDEWEB)

Discusses scaling of closed systems for cooling coal gas from black coal coking. Scaling rate and factors that influence scaling are analyzed. Physical and chemical properties of scale buildup on the inner walls of pipe cooling systems are evaluated. Water pH value and its effects on scaling and solubility of chemical compounds that form scale are discussed. Use of ammonium sulfate for scale control is analyzed. Consumption rate of ammonium sulfate depends on ambient temperature, water pH value and chloride content in return water. Formulae for calculating optimum content of ammonium sulfates for scale control are derived. 3 refs.

1989-08-01

182

A model for the calculation of vent clearing transients in pressure suppression systems  

International Nuclear Information System (INIS)

For the layout of a pressure suppression system of a light water cooled reactor (boiling water reactor) it is important to know the time dependent behavior of the vent clearing transient after a loss-of-coolant accident for two main reasons: time of the end of the vent clearing transient influences strongly the pressure and temperature maxima in the drywell and wetwell. Time-dependent behavior of the vent clearing transient influences pressure loads in the condensation pool of the wetwell and therefore pressure induced stresses to the structure. The time-dependent behavior of the water masses in the vent pipes and wetwell are described by the basic equations for a nonstationary incompressible friction flow: momentum equation, continuity equation and a correlation for the variation of the state of the gas volume in the wetwell above the water level. After many algebraic operations ...

1975-09-01

183

An experimental integrated absorption heat pump effluent purification system. Pt. 1: Operating on water/lithium bromide solutions  

Energy Technology Data Exchange (ETDEWEB)

The merits of single stage absorption heat pumps coupled to simple distillation for effluent treatment are discussed. An experimental integrated absorption heat pump effluent purification system (IAHPEPS) was built and operated with water-lithium bromide as a working mixture. This unit has been used to raise the temperature and hence, the vapour pressure of the impure water contained in one vessel, to the point where pure water vapour will distil from impure effluent solution (tap water or brine) and condense in a second vessel used to collect pure water. Pure effluent production rates of between 0.5 and 4.3 kg h{sup -1} were obtained. The actual coefficient of performance (COP{sub A}) and the heat pump effectiveness varied from 1.1 to 1.4 and 0.58 to 0.72, respectively. The results from the small scale systems indicate ...

1999-05-01

184

Innovative coke oven gas cleaning system for retrofit applications. Quarterly technical progress report No. 4, October 1, 1990 to December 31, 1990  

Energy Technology Data Exchange (ETDEWEB)

Work on this coke oven gas cleaning demonstration project (CCT-II) this quarter has been focused on Phase IIB tasks, and include engineering, procurement, construction, and training. Additionally, plans for changes in the operating schedule of the coke plant that affect the demonstration project are described. Engineering efforts are nearly complete. Remaining to be finalized is an assessment of electrical heat tracing/insulation needs for pipe lines, assessment of fire protection requirements, and instrument modifications. Procurement of all major equipment items is complete, except for possible additions to fire fighting capabilities. Major focus is on expediting pipe and structural steel to the project site. Civil construction is complete except for minor pads and bases as required for pipe supports, etc. Erection of the hydrogen sulfide and ammonia scrubber vessels is complete. Installation of ...

1993-10-22

185

Evaluation of structural integrity of crossover leg piping system with dynamic whip restraints  

Energy Technology Data Exchange (ETDEWEB)

Interference between the crossover leg of the Reactor Coolant System(RCS) and the Pipe Whip Restraints(PWR) has brought a degradation issue of the integrity of the Reactor Coolant System in Westinghouse type Nuclear Power Plants(NPPs) of Korea. According to the gap inspection carried out during planned overhaul (year 2000), interference between the crossover leg and the PWR was found in each RCS loop. This plant has had the high vibration problem on the RC pump 'B'. The reason for the high vibration in the RC pump 'B' had been massively surveyed and it was found that the crossover leg of RCS contacted with the PWR in hot condition. Since the contact between the crossover leg and the PWR changes the dynamic characteristics of the piping system for the RCS, this is considered as one reason for the high vibration. And a possibility of overstress on the crossover leg due to the contact with the PWR should be ...

2001-07-01

186

Surge-line thermal stratification: Displacements and fatigue damage computations  

Energy Technology Data Exchange (ETDEWEB)

Slow, unexpected displacements have been experienced in most pressurized water reactor (PWR) surge lines. Sometimes, these displacement lead to gap closure at the pipe whip restraints. These movements occur because of thermal stratification. This movement has the potential to increase stresses to valves, which may exceed the material yield stress. To understand this phenomenon, Framatome, Commissariat a l'Energie Atomique, and Electricite de France have undertaken large programs for the study of (1) thermal-hydraulic tests with a half-scale Plexiglas surge line, (2) thermal-hydraulic computations of permanent states and transients with a two-dimensional model, and (3) mechanical analysis of displacements and computation of fatigue damage due to stratification. This paper deals with the last subject. Avoiding stratification in piping by process modifications is difficult because of the high flow rate needed. ...

1989-01-01

187

Recursive distribution method for probabilistic fracture mechanics and its application to evaluation of LWR piping  

Energy Technology Data Exchange (ETDEWEB)

The present authors have previously developed a new method for Probabilistic Fracture Mechanics (PFM), which they call Recursive Distribution (RD) method. The method is based on the construction of the Lebesgue-Stieltjes measure through a deterministic mapping defining a crack growth process. In the present paper, its theoretical background is first discussed, and the Lebesgue decomposition of the measure is given. Then a numerical example of a Light Water Reactor (LWR)`s piping problem is solved by the present method, and the results are compared with those of the Monte Carlo (MC) method. In addition to leakage probability, a variation in stress cycles of the marginal distribution of an aspect ratio of a semi-elliptical surface crack is calculated, which will be used in a study on LBB evaluation.

1996-12-01

188

Ceramic linings beat coal plant's abrasion/corrosion problems  

Energy Technology Data Exchange (ETDEWEB)

A combination of erosion and corrosion at the Victoria Junction coal preparation plant in Sydney, Nova Scotia was causing serious problems. Schedule 80 mild steel pipes were starting to fail as well as some quarter-inch steel plates in the lauders and chutes. Some corrosion tests were carried out and the high chloride level in the process water was felt to be the single most important contribution to the corrosion problem. Cast basalt was selected as a solution to the pipe wear problem. Three different types of abrasion/corrosion-resistant tiling - basalt tiles, kalceram tiles and ceramic tiles were well suited to the chloride conditions at this plant.

1985-07-01

189

Turbulent flow in a channel with transverse rib heat transfer augmentation  

Science.gov (United States)

Turbulent flow in a 2D channel with repeated rectangular rib roughness was numerically simulated using a low Reynolds number form of the k-epsilon turbulence model. Friction factors and average Stanton numbers were calculated for various pitch to rib height ratios and bulk Reynolds numbers. Comparisons with experiment were generally adequate, with the predictions of friction superior to those for heat transfer. The effect of variable properties for channel flow was investigated, and the results showed a greater effect for friction than for heat transfer. Comparison with experiment yielded no clear conclusions. The turbulence model was also validated for a related problem, that of flow downstream of an abrupt pipe expansion.

1993-04-01

190

An assessment of the building sector efficiency resource for the Town of Handlova  

Energy Technology Data Exchange (ETDEWEB)

Purpose of this assessment for this town in the Slovak Republic is to develop information on the building sector energy efficiency and improvement potential for use by town management to support decisions on providing energy services to Handlova citizens. Objectives were to characterize baseline space and water heat energy use and efficiency improvement potential in the residential and nonresidential building sectors. Intention was to identify major areas of efficiency improvement potential and cost-effectiveness. Four levels of energy and fuel prices were used. A significant efficiency resource exists in the space and water heating end uses in these building sectors; it amounts to 42% of the total building sector space and water heat energy consumption.

1995-10-01

191

Cooling facility for reactor container  

International Nuclear Information System (INIS)

Cooling water is sprayed on the outer surface of an upper portion of a container, and a pool is formed by the cooling water flowing down while cooling the container. Further, the cooling water stored in the cooling water pool is recycled by a pump for spraying the cooling water on the outer surface of the upper portion of the container. Sufficient amount of cooling water is supplied for spraying the cooling water to the outer surface of the upper portion of the container so that the outer surface of the container is free from drying and a liquid membrane is formed on the entire surface. The amount of the cooling water is made greater than that of the cooling water evaporated when the entire amount of the heat generate in the reactor core of the reactor is transferred to the ...

1993-05-07

192

Flooded Underground Coal Mines: A Significant Source of Inexpensive Geothermal Energy  

Energy Technology Data Exchange (ETDEWEB)

Many mining regions in the United States contain extensive areas of flooded underground mines. The water within these mines represents a significant and widespread opportunity for extracting low-grade, geothermal energy. Based on current energy prices, geothermal heat pump systems using mine water could reduce the annual costs for heating to over 70 percent compared to conventional heating methods (natural gas or heating oil). These same systems could reduce annual cooling costs by up to 50 percent over standard air conditioning in many areas of the country. (Formatted full-text version is released by permission of publisher)

2007-04-01

193

Comparative performance of two types of evacuated tube solar collectors in a residential heating and cooling system. The progress report  

Science.gov (United States)

Two types of evacuated tube solar collectors have been operated in space heating, cooling and domestic hot water heating systems in Colorado State University Solar House I. An experimental collector from Corning Glass Works supplied heat to the system from January 1977 through February 1978, and an experimental collector from Philips Research Laboratory, Aachen, which is currently in use, has been operating since August 1978. A flat absorber plate inside a single-walled glass tube is used in the Corning design, whereas heat is conducted through a single glass wall to an external heat exchanger plate in the Philips collector. In comparison with conventional flat-plate collectors, both types show reduced heat losses and improved efficiency. For space heating and hot water supply in winter, the solar ...

1979-01-01

194

Safety considerations of active process water system shutdown for TAPP - 3 and 4  

International Nuclear Information System (INIS)

Active Process Water (APW) System, provided as unitized closed loop system in Tarapur Atomic Power Project Units-3 and 4, serves to remove heat from various heat exchangers. One of the important loads served by APW system is shutdown cooling heat exchangers and if APW shutdown is taken then reactor cannot be maintained in cold shutdown condition. It is estimated that after 7 days of reactor shutdown, if about 20% of the normal cooling flow to shutdown cooling heat exchangers is provided then along with keeping PHT in cold shutdown state, reactor components, moderator, end shield water, calandria vault water and calandria vault concrete temperature can be maintained within technical specification limits for extended duration. (author)

2005-12-01

195

PWR horizontal steam generator in USSR  

International Nuclear Information System (INIS)

This paper describes the construction of PWR horizontal steam generator in Soviet Union, the water chemistry treatment for secondary side, the design of steam separator, the test of heat transfer characteristics and operation. (author).

1985-01-01

196

Numerical Simulation of Cirrus Clouds - Fire Case Study and ...  

Science.gov (United States)

... being pulled out of water, the movement is restricted ... This heating depended on the particle size ... hydrometeor injection into the upper tropopause. ...

1991-08-12

197

An Experimental Study of Oil / Water Flow in Horizontal Pipes  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this thesis is to study the behaviour of the simultaneous flow of oil and water in horizontal pipes. In this connection, two test facilities are used. Both facilities have horizontal test sections with inner pipe diameters equal to 2 inches. The largest facility, called the model oil facility, has reservoirs of 1 m{sub 3} of each medium enabling flow rates as high as 30 m{sub 3}/h, which corresponds to mixture velocities as high as 3.35 m/s. The flow rates of oil and water can be varied individually producing different flow patterns according to variations in mixture velocity and input water cut. Two main classes of flows are seen, stratified and dispersed. In this facility, the main focus has been on stratified flows. Pressure drops and local phase fractions are measured for a large number of flow conditions. Among the instruments used are differential pressure ...

2001-07-01

198

Subcooled Flow Boiling in a Minichannel  

British Library Electronic Table of Contents (United Kingdom)

It has been considered that dry-out occurs easily in boiling heat transfer for a small channel, a mini- or microchannel, because the channel was easily filled with coalescing vapor bubbles. In the present study, the experiments of subcooled flow boiling of water were performed under atmospheric conditions for a horizontal rectangular channel for which the size is 1 mm height and 1 mm width, with a flat heating surface of 10 mm length and 1 mm width placed on the bottom of the channel. The heating surface has a top of copper heating block and is heated by ceramic heaters. In the high heat flux region of nucleate boiling, about 70-80% of the heating surface was covered with a large coalescing bubble and the boiling reached critical heat flux as observed by high-speed video. In the beginning ...

2011-01-01

199

Heat Transfer Characteristics of Tubular Thermal Reactor  

International Nuclear Information System (INIS)

Heat transfer augmentation based on the process intensification concept in heat exchangers and thermal reactors has received much attention in recent years, mainly due to energy efficiency and environmental considerations. The concept consists of the development of novel apparatuses and techniques that, compared to those commonly used today, are expected to bring dramatic improvements in manufacturing and processing, substantially decreasing equipment size, energy consumption, and ultimately resulting in cheaper, sustainable technologies. The objective of this paper was to investigate the heat transfer characteristics of tubular thermal reactor using static mixing technology. Glycerin and water were used as the test fluids and water was used as the heating source. The results for heat transfer rate were strongly influenced by tube geometry ...

200

Pipe crawlers  

International Nuclear Information System (INIS)

The patent concerns pipe crawlers, i.e. apparatus capable of moving along the bores of pipes and tubes. Pipe crawlers are employed for conveying inspection equipment along the bores of pipes and tubes. The pipe crawler comprises a piston and assembly system, which controls the movement of the crawler and supports the assembly centrally within the bore of the pipe or tube. (UK).

1984-11-29

201

Competition advantage by utilizing the gross calorific value-high potential for the local heat supply; Wettbewerbsvorsprung durch Brennwertnutzung. Hohes Potential bei der Nahwaermeversorgung  

Energy Technology Data Exchange (ETDEWEB)

The gross calorific value (H{sub o}) is the amount of heat which is generated by total combustion of a type of fuel. It also includes that part of heat which is generated by steam from evaporated water contained in heating gas. In conventional heating boilers, this heat portion is not being utilized at all. To utilize the gross calorific value, it is necessary to extract from the exhaust gas the evaporation heat bound in steam and to return this to the heating system. This means that the exhaust gas has to be chilled by the return water of the heating system and condensed in suitable heat exchangers to well below the dew point. (orig.) [Deutsch] Waermelieferanten im Bereich der Nahwaermeversorgung koennen durch die Anwendung verfuegbarer und bewaehrter ...

1999-01-01

202

Air-side performance of a parallel-flow parallel-fin (PF{sup 2}) heat exchanger in sequential frosting  

Energy Technology Data Exchange (ETDEWEB)

The thermal-hydraulic performance in periodic frosting conditions is experimentally studied for the parallel-flow parallel-fin heat exchanger, henceforth referred to as a PF{sup 2} heat exchanger, a new style of heat exchanger that uses louvered bent fins on flat tubes to enhance water drainage when the flat tubes are horizontal. Typically, it takes a few frosting/defrosting cycles to come to repeatable conditions. The criterion for the initiation of defrost and a sufficiently long defrost period are determined for the test PF{sup 2} heat exchanger and test condition. The effects of blower operation on the pressure drop, frost accumulation, water retention, and capacity in time are compared under the conditions of 15 sequential frosting cycles. Pressure drop across the heat exchanger and overall heat transfer coefficient ...

2010-09-15

203

A desiccant dehumidifier for electric vehicle heating  

Energy Technology Data Exchange (ETDEWEB)

Vehicle heating requires a substantial amount of energy. Engines in conventional cars produce enough waste heat to provide comfort heating and defogging/defrosting, even under very extreme conditions. Electric vehicles (EVs), however, generate little waste heat. Using battery energy for heating may consume a substantial fraction of the energy storage capacity, reducing the vehicle range, which is one of the most important parameters in determining EV acceptability. Water vapor generated by the vehicle passengers is in large part responsible for the high heating loads existing in vehicles. In cold climates, the generation of water vapor inside the car may result in water condensation on the windows, diminishing visibility. Two strategies are commonly used to avoid condensation on windows: windows are ...

1996-09-01

204

Pipe whip: a summary of the damage observed in BNL pipe-on-pipe impact tests  

Energy Technology Data Exchange (ETDEWEB)

This paper describes examples of the damage resulting from the impact of a whipping pipe on a nearby pressurised pipe. The work is a by-product of a study of the motion of a whipping pipe. The tests were conducted with small-diameter pipes mounted in rigid supports and hence the results are not directly applicable to large-scale plant applications where flexible support mountings are employed. The results illustrate the influence of whipping pipe energy, impact position and support type on the damage sustained by the target pipe.

1987-01-01

205

Pipe whip: a summary of the damage observed in BNL pipe-on-pipe impact tests  

International Nuclear Information System (INIS)

This paper describes examples of the damage resulting from the impact of a whipping pipe on a nearby pressurised pipe. The work is a by-product of a study of the motion of a whipping pipe. The tests were conducted with small-diameter pipes mounted in rigid supports and hence the results are not directly applicable to large-scale plant applications where flexible support mountings are employed. The results illustrate the influence of whipping pipe energy, impact position and support type on the damage sustained by the target pipe. (author).

206

Waste heat utilization in the thermal spa of Lavey-les-Bains; Etude de la valorisation des rejets thermiques des Bains de Lavey  

Energy Technology Data Exchange (ETDEWEB)

This final report for the Swiss Federal Office of Energy looks at the possibilities for improved waste water utilization in the Lavey-les-Bains thermal spa, Switzerland. According to the regulations in force, the temperature of the waste water rejected into the Rhone river shall not exceed 30 {sup o}C, what is currently not the case. Also the operational cost shall be reduced and the waste water quality improved. The installations are presented. From the two geothermal wells, mineral water comes out at an average flow rate of 940 l/min and a temperature of 63 {sup o}C. Actual waste water data are reported. The measured thermal water consumption data, including seasonal variations, are analysed by computerized simulation and measures to reduce the consumed volume by the optimization of internal procedures are evaluated. Measures to reduce the quantity of the ...

2004-07-01

207

Waste heat utilization in the thermal spa of Lavey-les-Bains  

International Nuclear Information System (INIS)

This final report for the Swiss Federal Office of Energy looks at the possibilities for improved waste water utilization in the Lavey-les-Bains thermal spa, Switzerland. According to the regulations in force, the temperature of the waste water rejected into the Rhone river shall not exceed 30 "oC, what is currently not the case. Also the operational cost shall be reduced and the waste water quality improved. The installations are presented. From the two geothermal wells, mineral water comes out at an average flow rate of 940 l/min and a temperature of 63 "oC. Actual waste water data are reported. The measured thermal water consumption data, including seasonal variations, are analysed by computerized simulation and measures to reduce the consumed volume by the optimization of internal procedures are evaluated. Measures to reduce the quantity of the rejected free ...

208

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 3, Water heaters, pool heaters, direct heating equipment, and mobile home furnaces  

Energy Technology Data Exchange (ETDEWEB)

This is Volume 3 in a series of documents on energy efficiency of consumer products. This volume discusses energy efficiency of water heaters. Water heaters are defined by NAECA as products that utilize oil, gas, or electricity to heat potable water for use outside the heater upon demand. These are major appliances, which use a large portion (18% on average) of total energy consumed per household (1). They differ from most other appliances in that they are usually installed in obscure locations as part of the plumbing and are ignored until they fail. Residential water heaters are capable of heating water up to 180{degrees}F, although the setpoints are usually set lower.

1993-11-01

209

Strain Rate Effects in SA-106 Carbon Steel Pipe,  

Science.gov (United States)

... rate on the tensile properties of SA-106 carbon steel pipe, in support of analysis and experimental modeling of postulated pipe whip in nuclear ...

1982-02-01

210

Parametric study of pipe whip behavior  

International Nuclear Information System (INIS)

A pipe whip test is one of the main subjects of the pipe rupture tests performed in Japan Atomic Energy Research Institute. In 1979, the pipe whip test of 4B, sch-80 pipe will be done under the BWR condition. As the preliminary analysis of this test, the pipe whip analysis of 4B, sch-80 pipe was implemented in order to make clear of the influences of the physical parameters on the pipe whip behavior. The pipe whip analysis was treated as nonlinear dynamic analysis of pipe-restraint system by using the general purpose finite element program ADINA. Overhang length, clearance between pipe and restraint, restraint length and cross section area of restraint were taken as physical parameters. It was clarified through this analysis how restraint displacement, restraint strain and ...

211

Standard radiation monitoring at Sendai nuclear power station  

International Nuclear Information System (INIS)

Standard radiation monitoring has been conducted at Sendai nuclear power station for the purpose of estimation of 'source activity' during refueling outage and evaluation of countermeasures to reduce dose rate. Selected objects of the monitoring are radiation dose rate at maintenance area, radiation field at each equipment and piping, coolant chemistry and plant operation condition. Monitored data indicates that 'source activity' variation can be estimated to some extent using influential factors, and that evaluation of change of loose crud activity, which is presumed to be represented by the dose rate at letdown heat exchanger, is necessary to further explain change in radiation field at main work area. (author).

212

Operating experience with condenser tubes made from copper alloys and new developments; Betriebserfahrungen mit Kondensatorrohren aus Kupferlegierungen und aktuelle Entwicklungen  

Energy Technology Data Exchange (ETDEWEB)

Copper alloys are a suitable tubing material for turbine condensers and heat exchangers. Due to problems with corrosions copper alloys increasingly are displaced by high-grade steel and titanium. Blockages and surface formation in the pipes, disturbance of the oxide coating formation, erosion and quality faults with the production are the causes for the corrosion. In the contribution under consideration counter measures are designated for the solution of the problems with corrosions. The application limits for different copper alloys are designated. Recommendations for the optimized operation are given.

2008-07-01

213

Evaluation of the corrosion and corrosion-mechanical damage of the primary piping material of WWER-440/V213c units in operating conditions  

International Nuclear Information System (INIS)

The sensitivity of the primary circuit material was examined at the Mochovce and Dukovany NPPs. No significant sensitivity of the base material or the weld metal to the initiation of corrosion cracking was observed. Thermal aging was found to accelerate significantly the corrosion fatigue kinetics in the material of the heat affected zone. The threshold values of the double amplitudes of the stress intensity factor were below 8 MPa/m"2 for the materials examined, with a cycle asymmetry coefficient of 0.65. The tests revealed no appreciable sensitivity to general corrosion, pitting, or intergranular corrosion. (J.B.). 7 tabs., 26 figs., 11 refs.

214

Change in high-temperature strength properties of 12Kh1MF steel in long-term loading under creep conditions  

Energy Technology Data Exchange (ETDEWEB)

Stress-rupture strength tests were made of metal steam pipe (12Kh1MF steel) in various conditions, the original, after aging under laboratory conditions (580{degrees}C, 10,000 h), and after long service. It was shown that the more the steel is hardened by heat treatment or cold plastic working in the original condition, the less it hardens in creep. It was established that softening in creep of steel with a moderate yield strength is caused primarily by aging and with a high yield strength by pore formation.

1995-01-01

215

Verification of zinc injection applicability to Japanese BWRs  

Energy Technology Data Exchange (ETDEWEB)

The verification test program on zinc injection applicability to Japanese BWRs was started in 1997. Laboratory tests using high temperature water loops under BWR reactor water conditions are in progress. This paper is an interim report on results obtained so far. Co-58 and Zn-65 were simultaneously used in the Co radioactivity buildup test to evaluate zinc injection suppression effects towards cobalt deposition on pre-oxidized stainless steel. The following results were obtained. The Co deposition was suppressed effectively by Zn injection, even when there was a pre-oxide film. For the test piping that had the pre-oxide film formed under the NWC (normal water chemistry) condition, when soaked under the HWC (hydrogen water chemistry) condition a large amount of Co-58 was taken into a small part of the inner layer. The distribution ratio of Co-58 in the inner layer and outer layer of ...

2002-07-01

216

Energy saving self-powered industrial dehumidifier  

Energy Technology Data Exchange (ETDEWEB)

An energy saving self-powered industrial dehumidifier for use in a building having a tap water conduit leading from a source of supply to utilization points is described comprising: a dehumidifying apparatus positioned in a stream of air to be dehumidified in the building. The dehumidifying apparatus comprising conduit means for diverting at least a portion of a relatively continuously moving stream of tap water from the tap water conduit through a heat exchanger positioned in a stream of air and returning the diverted portion to the tap water stream upstream of the utilization points. Water vapor in the stream of air will condense onto the heat exchanger when the tap water has a temperature below a dew point temperature of the air stream, thereby dehumidifying the air stream.

1988-07-26

217

Simplified solar fraction estimation for space and water heating at DOD installations. Final report  

Energy Technology Data Exchange (ETDEWEB)

A set of nomographs is provided which can be used to estimate the average annual solar fraction for solar space and water heating at a large number of DOD facilities. The solar fraction estimated from the nomograph is in close agreement with F-Chart 3.0 and allows for variation of the following parameters: annual load, collector area, collector transmittance-absorption coefficient, and collector overall loss coefficient.

1982-09-01

218

Development of cast-in-place concrete pile installation technique for application in the presence of artesian water; Hiatsu chikasui kasho ni okeru bashouchi kui sekoho no kaihatsu  

Energy Technology Data Exchange (ETDEWEB)

When a rotary excavator is operated at locations where there is artesian water, the aquiclude is fractured under pressure of the artesian water upon the penetration of the pile tip through the aquiclude. Since the equipment is provided with a gap for the reduction of friction between the casing and the excavation face, soil and sand near the pile tip burst forth out of the ground together with underground water through the casing or along the outer circumference of the casing. The newly contrived method introduced here is a double pipe process, in which a large casing (2.0m in diameter) is driven until it lands on the aquiclude, water is injected into the casing for the creation of equilibrium between the artesian head and the head in the casing, and finally a casing as large as the pile (1m in diameter) to be installed is used for the excavation of the artesian ...

1998-11-05

219

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

International Nuclear Information System (INIS)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-22

220

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

Energy Technology Data Exchange (ETDEWEB)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-01

221

The thermal response of an infinite line of open loop wells for ground coupled heat pump systems  

British Library Electronic Table of Contents (United Kingdom)

Ground thermal energy storage is a means of storing thermal energy underground during the summer and utilizing it during the winter. The main use of such a technology is in the heating, ventilating and air conditioning sector where the ground provides a stable temperature reservoir for a heat pump system. Heat pumps are mechanical systems that provide heating to a space in the winter, and cooling in the summer. They are increasingly popular because the same system provides both heating modes, depending on the direction of the cycle upon which they operate. The stable temperature reservoir allows the heat pump system to run at a higher efficiency. Thermal energy is transmitted to and from the ground by circulation of water through standing column geothermal wells. In commercial applications...

2011-01-01

222

A metal matrix for heat transfer enhancement during phase-change processes  

Energy Technology Data Exchange (ETDEWEB)

A metal matrix is inserted into a phase-change material to enhance the heat transfer during phase-change processes. The metal matrix tends to act like a heat transfer fin from the heated or cooled surface and to increase the effective thermal conductivity of the phase-change fluid. The scope of the study involves numerically modeling the heat transfer to and from constant-temperature cylindrical tubes surrounded by water during the freezing and melting processes. Comparisons of heat transfer with and without the metal matrix are made, with different porosities and densities of the metal matrix being examined. The results of this study are discussed in terms of the effectiveness of the metal matrix as a heat transfer enhancement device.

1994-12-31

223

Visualization of direct contact heat transfer between water and molten alloy  

Energy Technology Data Exchange (ETDEWEB)

We have been developing an innovative Steam Generator concept of Fast Breeder Reactors by using liquid-liquid direct contact heat transfer. In this concept, the SG shell is filled with a molten alloys, which is heated by primary sodium. Water is fed into the high temperature molten alloy, and evaporates by direct contact heating. In order to obtain the fundamental information to discuss the heat transfer mechanisms of the direct contact between the water and the alloy, this phenomenon was visualized by real-time neutron radiography. JRR-3M real-time thermal neutron radiography in Japan Atomic Energy Research Institute was used. Followings are main results. (1) The vigorous evaporation occurs in the molten alloy. This phenomena is different from the known phenomenon such as the evaporation of refrigerant R-113 in the water. (2) The ...

1996-06-01

224

Mathematical modeling of a direct contact humidification?dehumidification desalination process  

British Library Electronic Table of Contents (United Kingdom)

Using air as a carrier gas is common in humidification?dehumidification desalination processes. A computer program was written using mass and energy balances for modeling the process behavior. The parameters considered in this work were inlet air and fresh water recycle temperatures, inlet air flow rate, saline water and fresh water recycle flow rates, and saline water to air flow ratio. Results of simulation showed that increasing inlet air and fresh water recycle flow rate increases fresh water production. It was also found that heating the inlet air to humidification column or cooling the inlet water to dehumidification column increases the production rate but increasing water to air flow ratio in a humidifier leads to a lower production rate. The predicted effects of the parameters on ...

2009-01-01

225

Lead exposure via drinking water - unnecessary and avoidable; Bleiexposition ueber das Trinkwasser - unnoetig und vermeidbar  

Energy Technology Data Exchange (ETDEWEB)

Despite successful reduction of the general lead exposure, this heavy metal is still a matter of public concern due to the fact that associations with intellectual impairment or delayed puberty are found to correlate with very low lead blood concentrations. Lead in tap water is still an important contribution to lead exposure which may cause health risk for infants. Therefore, lead pipes should be completely sanitated by exchange against pipes made from more healthy materials. (orig.) [German] Trotz erfolgreicher Reduktion der allgemeinen Belastung ist Blei auch heute noch umweltmedizinisch relevant, weil es moeglicherweise bei niedrigeren als bisher angenommenen Belastungen gesundheitlich nachteilige Wirkungen, insbesondere waehrend der fruehkindlichen Entwicklung des Nervensystems, ausloest. Insbesondere Blei aus bleiernen Trinkwasserleitungen ist eine Belastung, die fuer Saeuglinge und Kleinkinder nach wie vor ein ...

2003-07-01

226

Some sensitivities during a LWR severe core-damage sequence  

International Nuclear Information System (INIS)

Stable boiloff of core water during a severe LWR accident, that is, boiloff driven only by the decay power generated below the water level, is tractable analytically and is relatively insensitive to axial power distribution. As might be expected, calculated accident event times are sensitive to the fidelity of the decay power model. During later stages of boiloff, heat transfer or transport of energy from above the water level to the residual water can result in an unstable condition during which the boiloff rate increases greatly. The unstable boiloff phenomenon illustrates the highly nonlinear influence of core heat transfer during meltdown and emphasizes the great accuracy requirements which attend the modeling of the accident during periods of enhanced heat transfer when significant zirconium oxidation is possible.

1981-12-04

227

Study on the application of a geothermal heat pump; Etude sur l`application d`une pompe a chaleur geothermique  

Energy Technology Data Exchange (ETDEWEB)

The heating system of the `Centre integre de mecanique industrielle de la Chaudiere`, in Saint-Georges, Quebec, is based on a solar wall and a geothermal heat pump with a glycol/water mixture circulating in 44 wells that are 100 m deep. With installation costs below $25 per sq.m, more than 85 per cent of the heating needs of the 9500 sq.m centre were supplied by geothermal power. The geothermal heat pump is composed of a well field and two 211-kW cooling units, each equipped with four coiled compressors. In winter, heat is pumped from the earth and in summer, a heat exchanger with control valves allows to heat to be dumped back into the earth. The monitoring and simulation of the system proved its efficiency, considering the climatic conditions in Quebec. The annual consumption of geothermal heating ...

1996-12-01

228

Quantitative model of vapor dominated geothermal reservoirs as heat pipes in fractured porous rock  

Science.gov (United States)

We present a numerical model of vapor-dominated reservoirs which is based on the well-known conceptual model of White, Muffler, and Truesdell. Computer simulations show that upon heat recharge at the base, a single phase liquid-dominated geothermal reservoir in fractured rock with low matrix permeability will evolve into a two-phase reservoir with B.P.D. (boiling point-for-depth) pressure and temperature profiles. A rather limited discharge event through cracks in the caprock, involving loss of only a few percent of fluids in place, is sufficient to set the system off to evolve a vapor-dominated state. The attributes of this state are discussed, and some features requiring further clarification are identified. 26 refs., 5 figs.

1985-03-01

229

Peel-off case failure in thermal explosions observed by the deflagration cylinder test  

British Library Electronic Table of Contents (United Kingdom)

We have discovered a previously unidentified thermal explosion mode using the Los Alamos deflagration cylinder test (DFCT). The DFCT is a "pipe bomb"-style test similar to the detonation cylinder test (DTCT), which has been used for many years to calibrate detonation product equations of state. The shot is heated in an oven to a uniform test temperature. The pre-heated high explosive (HE) is triggered by a hot wire initiator on one end. The tube is back-illuminated by a bright light source, and its combustion-driven deformation and subsequent break-up are observed by a high-speed framing camera. Like the DTCT, the DFCT tube wall motion provides the primary diagnostic. A variety of reactive responses are possible, including quasi-steady deflagration and deflagration-to-detonation transition...

2009-01-01

230

Microgravity two-phase flow regime modeling  

Energy Technology Data Exchange (ETDEWEB)

A flow pattern or flow regime is the characteristics spatial distribution of the phases of fluid in a duct. Since heat transfer and pressure drop are dependent on the characteristic distribution of the phases, it is necessary to describe flow patterns in an appropriate manner so that a hydrodynamic or heat transfer theory applicable to that pattern can be chosen. The objective of the present analysis is to create a flow regime map based on physical modeling of vapor/liquid interaction phenomena in a microgravity environment. In the present work, four basic flow patterns are defined: dispersed flow, stratified flow, slug flow, and annular flow. Fluid properties, liquid and vapor flow rates, and pipe size were chosen as the principal parameters. It is assumed that a transition from one flow pattern to another will occur when there is a change in the dominant force which controls that flow pattern. The forces considered in ...

1987-01-01

231

Flow visualization II Proceedings of the Second International Symposium, Bochum, West Germany, September 9-12, 1980  

Energy Technology Data Exchange (ETDEWEB)

Applications, techniques, instrumentation, and interpretation of flow visualization are discussed. Methods of using flow visualization for the examination of combustion in furnaces, heat transfer with heat exchangers, and in fluid engines are explored, along with flow visualization in food processing, steel-casting, and process engineering. Further attention is given to pipe and channel flow, flow separation in laminar flow and around oscillating airfoils, wakes and vortices, supersonic flow and shock waves, and stratified flow and oceanography. The visualization of boundary layers is considered for various conditions, and applications for multiphase flow, rheology, and medical problems are detailed. Oil film, dry-surface coating, chemical, fluorescent, and minituft methods are presented, as well as the use of tracers, optical techniques, strobe lights, lasers, computerized data acquisition, and hot-wire anemometry.

1982-01-01

232

Design and performance of the solar-powered floor heating system in a green building  

Energy Technology Data Exchange (ETDEWEB)

In the green building of Shanghai Research Institute of Building Science, the evacuated tubular solar collectors with a total area of 150 m{sup 2} were installed to provide heating for the covered area of 460 m{sup 2}. The floor heating coil pipes were made of high-quality pure copper with the dimension of {phi} 12 x 0.7 mm. Under typical weather condition of Shanghai, the average heating capacity was 25.04 kW during the working hours from 9:00 to 17:00, which was sufficient to keep indoor thermal environment. The average electric COP of the floor heating system was 19.76 during the system operation. Compared with the widely used air-source heat pump heating systems with the electric COP of 3.5 in Shanghai, the solar-powered floor heating system shows great potential in energy conservation in winter. With respect to the ...

2009-07-15

233

Modeling of snow melting and uniform wetting front migration in a layered subfreezing snowpack  

Energy Technology Data Exchange (ETDEWEB)

A method of modeling freeze-thaw cycles of naturally deposited snowpacks is presented. The model involves the Stefan condition as an independent governing equation on the exterior moving boundary to calculate snowpack thinning, flow of water through a variably saturated layered porous medium as described by the Richards equation, and heat conduction with a phase change. The heat conduction problem was treated in two ways. Local heat conduction between a snow grain and its surrounding water film was treated by using a simple energy balance. Global heat conduction with a phase change (the Stefan problem) was introduced to calculate the space-time temperature distribution. In order to handle multiple interior moving boundaries, a specific form of the enthalpy formulation was used for heat conduction with a phase change. Changing material ...

1994-08-01

234

GRI's Gas Appliance Technology Center Activities at Battelle. Final report, 1986-1992  

Science.gov (United States)

The Gas Research Institute established the Gas Appliance Technology Center (GATC) in 1982 to develop improved gas appliances. Between 1986 and 1992, the scope of GATC activities at Battelle included technology transfer and overall industry support, residential appliances, commercial appliances, and residential space conditioning. The following tasks are representative of the GATC activities described in the report; gas burner technology, appliance venting, emissions, water heating, range/oven technology, self-powered appliances, commercial cooktop burners, reconstituting ovens, appliance reliability improvement, combination space-heating/water-heating systems, condensing heat exchangers, corrosion testing, and space heating technology. The report includes references to available sources for further reading.

1993-08-01

235

Thermal-hydraulic characteristics of boiling water two-phase flow in narrow horizontal rectangular channel  

International Nuclear Information System (INIS)

Heat transfer and flow characteristics of water boiling flow were experimentally investigated in narrow horizontal rectangular channels with the gaps of 0.6mm-2.03mm. The heat transfer of two-phase boiling flow was weakend in smaller gap. The two-phase friction pressure drop decreased with the gap size and the two-phase friction multipliers were smaller compared with those in normal channels. Correlations to predict te boiling heat transfer coefficients were obtained. (author)

2003-05-28

236

Reliability analysis for stiff versus flexible piping  

Energy Technology Data Exchange (ETDEWEB)

The overall objective of this research project is to develop a technical basis for flexible piping designs which will improve piping reliability and minimize the use of pipe supports, snubbers, and pipe whip restraints. The current study was conducted to establish the necessary groundwork based on the piping reliability analysis. A confirmatory piping reliability assessment indicated that removing rigid supports and snubbers tends to either improve or affect very little the piping reliability. We then investigated a couple of changes to be implemented in Regulatory Guide (RG) 1.61 and RG 1.122 aimed at more flexible piping design. We concluded that these changes substantially reduce calculated piping responses and allows piping redesigns with significant reduction in number of ...

1985-11-01

238

PWR primary circuit piping installation of Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

The installation procedure, the fabrication, fitting up, positioning, adjustment and welding of piping, examinations, hydrostatics testing and insulation of piping for reactor primary circuit piping of Daya Bay Nuclear power Plant are briefly described.

239

AIR BREATHING DEVICE FOR PIPE LINE  

J-STORE (Japan)

Full Text Available

2004-11-29

240

Excessive copper concentrations in the tap water of households with copper pipes and an assessment of possible health hazards for infants. First results of a study; Gesundheitliche Gefaehrdung ungestillter Saeuglinge durch Kupfer in Haushalten mit kupfernen Trinkwasserleitungen. Erste Ergebnisse einer prospektiven Studie  

Energy Technology Data Exchange (ETDEWEB)

To determined precisely a possible connection between the amount of copper in tap-water and the risk of early childhood liver disease, it was attempted through an epidemiological survey, to determine the extent of excessive concentrations of copper in the tap-water of households with copper pipes. Water samples from 956 households were tested for copper, and the state of health of the infants in these households was documented. Infants who had been fed using water with a copper concentration of 0.8 mg/l or more received a paediatric examination with a blood serum analysis to rule out any liver damage. A copper level greater than 0.8 mg/l was found in only 2% of the households examined. Eight infants were examined by a paediatrician and their serum was analysed. These infants had either been breast-fed to the 12th week or had received more than 200 ml of tap ...

2000-04-01

241

Removal of uranium by biosorption  

Energy Technology Data Exchange (ETDEWEB)

The technology developed here will exploit the ability of microorganisms to remove dissolved metals from aqueous solutions. Microbial sorbents for uranium will be immobilized biosorbents will be deployed ex situ within flow-through reactors for the continuous or semicontinuous treatment of recovered wastewaters. The proposed technology will primarily be applied within a pump-and-treat process using immobilized biosorbents for the large-scale, long-term remediation of uranium-laden surface water or groundwater impoundments (environmental restoration). The technology may be equally useful as an ``end-of-pipe`` treatment of process effluents (waste management). Successful operation of this process will achieve immobilization of the targeted waste and accompanying volume reduction.

1993-06-01

242

Relining of scrubbers in flue gas desulfurization plants  

Science.gov (United States)

Rubber lining is used as a corrosion protection material in European flue gas desulfurization plants, for scrubbers, tanks, pipe systems, etc. Although these rubber linings can last more than 15 years, relining still is necessary. The difficulty of shutting down power station units requires that the time scale of this replacement be kept to a minimum. High-pressure water systems have proven successful as an efficient method for removal of the old lining. The working steps and time scale are demonstrated for one such relining case.

1999-09-01

243

Modeling of feed water check valves using RELAP5; Modellierung von Speisewasserrueckschlagventilen in RELAP5  

Energy Technology Data Exchange (ETDEWEB)

Westinghouse Electric Germany GmbH has developed fluid dynamic models for medium-actuated armatures using the thermal hydraulic code RELAP5 in order to reach a more realistic description of the armature behavior including fluid-structure interactions in case of transient flow conditions in piping systems. The contribution is concerned with the modeling of damped check valves. The model allows the description of the behavior during opening and closure of a check armature. The calculated results show good agreement with the available measured data.

2009-07-01

244

Technical considerations for flexible piping design in nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

The overall objective of this research project is to develop a technical basis for flexible piping designs which will improve piping reliability and minimize the use of pipe supports, snubbers, and pipe whip restraints. The current study was conducted to establish the necessary groundwork based on the piping reliability analysis. A confirmatory piping reliability assessment indicated that removing rigid supports and snubbers tends to either improve or affect very little the piping reliability. A couple of changes to be implemented in Regulatory Guide (RG) 1.61 and RG 1.122 aimed at more flexible piping design were investigated. It was concluded that these changes substantially reduce calculated piping responses and allows piping redesigns with significant reduction in number of ...

1985-03-15

245

Experimental and theoretical studies on humidification-dehumidification-desalination  

Energy Technology Data Exchange (ETDEWEB)

The shortage of fresh water is increasing at alarming levels, even in temperate zones. Desalination of brackish and seawater is being considered as a solution to growing water demands. Seawater desalination can be accomplished through reverse osmosis, vapor compression, vapor absorption and thermally driven systems. The most suitable process for large-scale desalination plants is successive brine evaporation-condensation with intermediate heat recovery. However, higher process efficiency could be achieved. The use of low temperature heat sources in seawater desalination requires an efficient method of evaporation and condensation at relatively low vapor pressures. This could be achieved in a humidification-dehumidification process using circulated air to enhance evaporation of water. Simulation models, however, neglect either the heat of evaporation or the ...

2006-07-01

246

Experimental and analytical studies of four-inch pipe whip tests under PWR LOCA conditions  

Energy Technology Data Exchange (ETDEWEB)

In the tests, the effects of the overhang length on the pipe whip behavior of the pipe-restraints system were studied by measuring the strains and deformations of the test pipe and restraints, and the restraints forces. The equation for predicting the maximum strain at the outer surface of the pipe was derived using a static equilibrium condition. The calculated maximum strains at the outer surface of the pipe agree fairly well with experimental data. The dynamic response analysis of the pipe-restraints system was conducted by the finite element program ADINA. The applicability of the ADINA program to the pipe whip analysis is made clear through this analysis.

1984-01-01

247

Microwave drying of fine coal  

Energy Technology Data Exchange (ETDEWEB)

Drying fine coal by microwaves is now being considered as a viable option by some coal producers. The interest in microwaves is due to problems encountered with current thermal or hot-air drying methods. The technical feasibility of drying minus 5mm coal fines by microwaves was demonstrated using pilot-scale continuous processing system. Results showed that water absorbs microwave energy significantly; but coal does not. Secondly, microwave energy heats only the water, unlike existing drying methods, which heat both water and coal. Finally, the method was found to be energy efficient and minimised the generation of dust.

1989-03-01

248

Pipe behaviour in bottom ash slurry systems  

Energy Technology Data Exchange (ETDEWEB)

This study presents the results of an 18-year long investigation of pipe deterioration in cyclone slag slurry transport. The goal was to study pipe behaviour in this extremely abrasive service and select an optimum piping material. Comparisons are given for high quality alloy cast steel pipes and pipes alined with cast basalt rings marketed under the name Abresist.

1982-09-01

249

Pipe behaviour in bottom ash slurry systems  

Energy Technology Data Exchange (ETDEWEB)

This study presents the results of an 18-year long investigation of pipe deterioration in cyclone slag slurry transport. The goal was to study pipe behaviour in this extremely abrasive service and select an optimum piping material. Comparisons are given for high quality alloy cast steel pipes and pipes lined with cast basalt rings marketed under the name Abresist. Based on the results, thoughts are offered on the broader meanings of certain findings.

1982-09-01

250

Method of controlling the coolant level in the cooling system of a nuclear power plant  

International Nuclear Information System (INIS)

Object: To prevent a sudden drop in the level of a coolant in a annular pipe encased within a downcomer pipe. Structure: The coolant levels in annular pipes encased within downcomer pipes are simultaneously measured by level gauges which generate signals representative of coolant levels. The signals are fed to a level control system which will actuate valves to regulate the cover gas pressure in order to average the level differences among the annular pipes in different downcomer pipes. (Kamimura, M.).

251

Overview of Cooling Water System for the KSTAR 1st Plasma Experiment  

International Nuclear Information System (INIS)

The KSTAR cooling water system (CWS) consists of a primary cooling water system (PCWS), a secondary cooling water system (SCWS), and a de-mineralizing and de-ionized water system (DIWS). The PCWS cooling loops have been made for the poloidal field (PF) and toroidal field (TF) magnet power supplies (MPS), vacuum vessel (VV), electron cyclotron heating (ECH), ion cyclotron heating (ICRH), vacuum pumps, diagnostics, helium facility, etc. The CWS had been done individual commissioning of each system to confirm the design specifications by the end of 2006 and had gradually begun operation for the KSTAR ancillary devices by March 2008

2009-05-01

252

Research and Service Experience with Environmentally-Assisted Cracking in Carbon and Low-Alloy Steels in High-Temperature Water  

Energy Technology Data Exchange (ETDEWEB)

The most relevant aspects of research and service experience with environmentally-assisted cracking (EAC) of carbon (C) and low-alloy steels (LAS) in high-temperature (HT) water are reviewed, with special emphasis on the primary pressure boundary components of boiling water reactors (BWRs). The main factors controlling the susceptibility to EAC under light water reactor (LWR) conditions are discussed with respect to crack initiation and crack growth. The adequacy and conservatism of the current BWRVIP-60 stress corrosion cracking (SCC) disposition lines (DLs), ASME III fatigue design curves, and ASME XI reference fatigue crack growth curves, as well as of the GE EAC crack growth model are evaluated in the context of recent research results. The operating experience is summarized and compared to the experimental/mechanistic background knowledge. Finally, open questions and possible topics for further research are identified. ...

2005-11-15

253

The building tomorrow and after..; Le batiment demain et apres-demain..  

Energy Technology Data Exchange (ETDEWEB)

During its jubilee, the French building technical and scientific centre (CSTB) has organized a colloquium about the future tendencies of buildings evolution in the 20 forthcoming years: autonomy in energy production and wastes or effluents management, reduction of water consumption and management of water, hot water production and space heating, bio-sensors for the management of indoor air-quality, control of noise environment using active acoustic systems etc.. (J.S.)

1998-01-01

254

Lamp system for uniform semiconductor wafer heating  

Energy Technology Data Exchange (ETDEWEB)

A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.

2001-01-01

255

Depth of origin of the gas content in thermal waters  

Energy Technology Data Exchange (ETDEWEB)

The gas composition of recent thermal waters is in perfect conformity with their geologic-tectonic positions. The composition of gas-liquid inclusions in the basic-hyperbasic xenoliths of basaltoid lavas depends on the depth from which xenoliths are supplied. (The depth is determined by using the methods of geological thermobarometers). By comparing available data the conclusion was drawn that the gas compositions of thermal waters reflect the depth of generation of deep fluid which heats them and depends on the penetration depth of the fluid-conducting fissure zones.

1980-01-01

256

Telephone exchange Feutersoey - first pilot plant of the PTT with solar collectors  

Energy Technology Data Exchange (ETDEWEB)

In the course of this year six local exchange offices with alternative heating and hot water plants were started up in Switzerland. They are all of the same building type, designed for not more than 1000 telephone subscribers and for the same architectural conditions. However, the buildings are situated in different areas of the country and are thus subject to different environmental conditions. Solar collectors supplemented by electricity boilers are fitted to two of these objects. Heat pumps are operated in two other exchange offices while the last two are equipped with electric heating devices. For purposes of comparison two new test plants of the same size with oil heating devices are set up.

1981-01-01

257

Designer's handbook for forced-cooled high-pressure oil-filled pipe-type cable systems. Final report  

Energy Technology Data Exchange (ETDEWEB)

This handbook provides the necessary tools for the engineer to design forced-cooled HPOF pipe-type cable systems. It represents the final objective of a major project which included an extensive research program at the Waltz Mill Forced-Cooling Test Facility. The formulas and procedures presented in this handbook are consistent with the results of this program as well as other full-scale and model investigations. Introductory material, including historical information, general design concepts and basic heat transfer and fluid dynamics theory is given for those who are unfamiliar with the fundamental principles of forced-cooling. The nucleus of the handbook consists of equations and calculating procedures for determining forced-cooled parameters and thermal/hydraulic performance levels. Both simple and sophisticated procedures have been provided, with the more complex procedures treating such areas as the thermal interaction between cable ...

1984-07-01

258

Two-phase flow regime characterization in a PWR hot leg with candy cane geometry  

International Nuclear Information System (INIS)

This paper describes a series of tests investigating two-phase flow regimes in a transparent model of a PWR hot leg. Test conditions were selected to cover a wide range of gas and liquid superficial velocities (.01 m/s 2 m/s) were also performed for comparison with semi-analytical predictions. Results include average void fractions, flow rates, and visual characterizations of the two-phase flow phenomena. Results show generally good agreement with Taitel and Duckler flow regime map and Zuber-Findlay correlation for average void fraction in vertical pipes. Results also indicate that flow regimes and collapsed liquid level (void fraction) are more strongly dependent on air flow rate (air superficial velocity) than water flow rate (water superficial velocity).

1984-10-01

259

Construction Progress of the Cooling and Ventilation in the LHC Project  

CERN Document Server

The Cooling and Ventilation Group has started the LHC construction work in September 1999 and will get into full activity when LEP will be stopped and dismantled: in total 12 major contracts for an amount of about 120 MCHF will be established to build the needed installations for the LHC. The author will report on the current works that are in progress on the different LEP Points distinguishing between the Ventilation and the Water Cooling installations. The Ventilation work, completed in the new surface buildings in Points 18, is currently held in Points 4 and 5. Point 1 will follow in the near future. The work for the Cooling plants comprehend the pumping stations, the cooling towers and the chilled water production stations in Points 1 and 5, the buried pipes in Points 1 and 4. For all of these activities, an updated report of the progress of the work, of the planning and of the expenses is given. Finally, a short ...

2001-01-01

260

Studies on water treatment by adsorption. Kyuchaku ni yoru mizushori  

Energy Technology Data Exchange (ETDEWEB)

This paper summarizes studies on the water treatment by adsorption, as for the adsorption during water treatment, reactivation of activated charcoal, and clarification of heating process. Reactivation of activated charcoal for the water treatment is carried out through drying in the heating furnace. Basic problems are the recovery degree of adsorption performance of reactivated activated charcoal and the recovery yield. Behavior of the activated charcoal in the heating reactivation furnace is divided into three stages including drying process, heating process, and gasification process. Among these processes, behaviors of organic matters during heating process are described. Thermogravimetric analyses (TGA) were conducted for activated charcoals adsorbing various organic matters in aqueous solutions. Three types of ...

1994-06-05

261

Final report for the DOE Suede Project, (solar utilization/economic development and employment project)  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this solar energy project was to design, manufacture, install, maintain and evaluate solar heating systems in order to stimulate community acceptance of the practicality of solar applications, reduce non-renewable energy resource consumption, and decrease residential expenditures for energy. The project also provided skill training and experience for CETA employees in the design, manufacture, and installation of solar energy equipment systems. CDC's contract had four separate solar energy projects; namely: Domestic Water Heating Systems for four Single-Family Homes; Domestic Water Heating for an industrial building; Domestic Water Heating for a (4) unit apartment complex (includes (12) supplemental space heating units); and Integral Passive Water Heaters and Energy ...

1983-10-19

262

Thermal energy storage system with stearic acid as phase change material  

Energy Technology Data Exchange (ETDEWEB)

A simple tube-in-tube heat exchanger system for thermal energy storage employing stearic acid as PCM has been investigated. The performance and heat transfer characteristics of such a system were studied. Phase transition temperature range and times were measured and the speed of the phase transition front was computed. The melting front was found to move in the radial direction inward as well as in the axial direction from the top toward the bottom of the phase change material PCM tube. The speed of the melting front is enhanced by a convection heat transfer mechanism in the melted PCM. The heat transfer rate and, consequently, phase transition time can be altered by changing the water inlet temperature to the heat exchanger. In addition, a faster phase transition is realized by placing the heat exchanger in a horizontal position rather ...

1994-10-01

263

MINERGIE modules: heat pump - heat pump/solar - wood - wood/solar; Minergie-Module Waermepumpe - Waermepumpe/Solar - Holz - Holz/Solar  

Energy Technology Data Exchange (ETDEWEB)

This research report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that examined the feasibility of setting up 'MINERGIE' low-energy-consumption module standards for the production of heat in small residential buildings. The aims of the standards and the basic idea behind the MINERGIE-modules are discussed. The concepts of the modules for heat pumps and wood-fired heating systems and their combination with solar installations are examined, as are their areas of application. The requirements placed on the modules are listed. System concepts, including simple schematics for typical installations, are presented for wood-log, wood-chippings and pellets-fired systems as well as for ground-loop and air-water heat pump systems as well as their solar-aided counterparts. The results of cost-benefit analyses are presented and questions ...

2005-07-01

264

Horizontal ground coupled heat pump: Thermal-economic modeling and optimization  

Energy Technology Data Exchange (ETDEWEB)

The modeling and optimizing processes of a Ground Coupled Heat Pump (GCHP) with closed Horizontal Ground Heat eXchanger (HGHX) are presented in this paper. After thermal modeling of GCHP including HGHX, the optimum design parameters of the system were estimated by minimizing a defined objective function (total of investment and operation costs) subject to a list of constraints. This procedure was performed applying Genetic Algorithm technique. For given heating/cooling loads and various climatic conditions, the optimum values of saturated temperature/pressure of condenser and evaporator as well as inlet and outlet temperatures of the water source in cooling and heating modes were predicted. Then, for our case study, the design parameters as well as the configuration of HGHX were obtained. Furthermore, the sensitivity analysis of change in the total annual cost of the system and ...

2010-12-15

265

Comparison of stomach contents and condition of two catfish species living at ambient temperatures and in a heated discharge  

International Nuclear Information System (INIS)

The lower condition factors for two catfish species in water heated by effluents from APCo's Glen Lyn, Virginia plant as compared to control areas probably is not due to lack of food as evidenced by macroinvertebrate sampling and the fact that only 4.3 percent of the catfish stomachs were empty. Results suggested that young-of-the-year channel catfish were nonselectively eating food organisms present at both control and heated stations. The difference between stomach contents of flatheat catfish from the heated site and fauna available at that site indicated that fish were either moving out of the heated area to feed or were selectively feeding on organisms (particularly mayflies) which were in the substrate or drifted into the heated area. Stomach contents of the two species and distribution and abundance of the macroinvertebrate benthos community are detailed.

266

Indirect heating of natural gas using vapor chambers; Aquecimento indireto de gas natural com uso de camaras de vapor  

Energy Technology Data Exchange (ETDEWEB)

Operation safety and reliability are major guidelines in the design of city-gate units. Conventional natural gas heaters operate by a indirect mechanism, where liquid water is used to transfer heat by natural convection between the combustion chamber and the natural gas coil. In this work, the concept of vapor chamber is evaluated as an indirect gas heater. In a vapor chamber, liquid water is in contact with the heat source, and vaporizes. The vapor condenses in contact with the heat sink. A reduced scale model was built and tested in order to compare these two heating concepts where the combustion chamber was replaced by electrical cartridge heaters. This engineering model can operate either as a conventional heater or as a vapor chamber. The comparison between the concepts was done by inducing a controlled power to the cartridges and by measuring the resulting ...

2005-07-01

267

Reliability analysis of stiff versus flexible piping. Final project report  

Energy Technology Data Exchange (ETDEWEB)

This research project is to develop a technical basis for flexible piping designs which will improve piping reliability and minimize the use of pipe supports, snubbers, and pipe whip restraints. This study indicated that piping design can be made more reliable by some reduction of rigid supports and/or snubbers. This study also confirmed that the malfunction of pipe whip restraints introduced higher thermal stresses and tended to reduce the overall piping reliability. Finally, our results indicated that supports in a flexible piping design may need to be reevaluated and that the elimination of pipe supports which are close to components should be done with care in order to minimize the impact on the component reliability.

1985-05-01

268

Achievement report in fiscal 2000. Model project to reduce electric power consumption at cement burning plant; 2000 nendo seika hokoku. Semento shosei plant denryoku shohi sakugen model jigyo  

Energy Technology Data Exchange (ETDEWEB)

In order to serve for efficient energy utilization and environmental improvement in the Republic of Vietnam, a 'Model project to reduce electric power consumption at cement burning plant' has been implemented. This paper summarizes the achievements. This project is intended to add an advanced, matured and reliable electric power generation facility using cement waste heat to the existing cement plant in Vietnam to produce steam and generate power by utilizing the waste heat generated from the preheating process in the burning plant. The present project has performed the detailed designing on the piping, electric facilities and instrumentation based on the basic agreement on the project. Fabrication of the piping has been executed by the Vietnam side. Valves and electric devices were procured and transported, including those fabricated in the previous fiscal year. Technology guiding ...

2002-03-01

269

Detection of concealed mercury with thermal neutrons  

Energy Technology Data Exchange (ETDEWEB)

In the United States today, governments at all levels and the citizenry are paying increasing attention to the effects, both real and hypothetical, of industrial activity on the environment. Responsible modem industries, reflecting this heightened public and regulatory awareness, are either substituting benign materials for hazardous ones, or using hazardous materials only under carefully controlled conditions. In addition, present-day environmental consciousness dictates that we deal responsibly with legacy wastes. The decontamination and decommissioning (D&D) of facilities at which mercury was used or processed presents a variety of challenges. Elemental mercury is a liquid at room temperature and readily evaporates in air. In large mercury-laden buildings, droplets may evaporate from one area only to recondense in other cooler areas. The rate of evaporation is a function of humidity and temperature; consequently, different parts of a building may be sources or sinks of mercury ...

1994-08-18

270

The numerical simulation on low-level radioactive waste water, low-temperature cooling water drained effect of implement from the Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

In this paper, we calculated the radioactive concentration distribution of radioactive waste water, the temperature distribution of drained cooling water and the effect of implement from the Daya Bay Nuclear Power Plant on nearby waters range, discussed and analysed some problems of computational results and computation with Alternating Direction Implicit Method (ADI). The contents of the article included: the establishment of two-dimension tidal current equation, radioactive waste water pollutant dispersion equation and cooling water heat convection diffusion equation, the numerical difference calculation model of tidal current field, concentration field as well as temperature field, effect impingement with ADI method, numerical calculation results. The result of research showed that: when the Daya Bay Nuclear Power Plant is on normal operation and after the ...

271

Flow Vaporization of CO{sub 2} in Microchannel Tubes  

Energy Technology Data Exchange (ETDEWEB)

Carbon dioxide is receiving renewed interest as an efficient and environmentally safe refrigerant in a number of applications, including mobile air conditioning and heat pump systems, and hot water heat pumps. Compact heat exchangers for CO{sub 2} systems are designed with small-diameter tubing. The purpose of this study is therefore to provide a better basis for understanding and predicting heat transfer and pressure drop during flow vaporization of CO{sub 2} in microchannels. The ''unusual'' properties of carbon dioxide give heat transfer and two-phase flow characteristics that are very different from those of conventional refrigerants. Examples of these differences are the much higher pressure, the resulting high vapour density, a very low surface tension, and a low liquid viscosity. High pressure and low surface tension ...

2002-07-01

272

Influence of two systematic parameters on the geothermal heat pump system operation  

Energy Technology Data Exchange (ETDEWEB)

In order to match the output capacity of a geothermal heat pump system (GHPS) with the actual load requirement, research has been carried out in finding the influence of two systematic parameters, the water flow rate inside the condenser and the compressor input frequency on the GHPS operation. Experiments are done on a small-scale GHPS at the water flow rate ranging from 0.054 kg/s to 0.174 kg/s and the frequency from 30 Hz to 55 Hz. The analysis of the experimental data reveals the relationships among the compressor frequency, the water flow rate and other important parameters such as coefficient of performance (COP), heat capacity and compressor power input. The conclusions in the paper can serve as some guidance to the load adjustment of GHPS. (author)

2003-01-01

273

Shielding options for the ITER conceptual design  

Energy Technology Data Exchange (ETDEWEB)

Several shield options were analyzed for the ITER conceptual design to minimize the nuclear responses in the toroidal field (TF) coils. The total nuclear heating in the physics phase and the insulator dose in the technology phase are the most critical parameters in the design process. The first shield option has type 316 stainless steel and water shielding material. Steel and water also serve as structural material and coolant, respectively. The second option is similar to the first except that borated water is used instead of ordinary water. The other two options include a small layer of lead or boron carbide (B{sub 4}C) at the back of the shield. The last three shield options were considered to reduce the nuclear heating in the toroidal field coils relative to the steel/water shield. An optimization process was performed taking into ...

1989-10-01

274

Enhancement of convective heat transfer by using microencapsulated PCM slurry  

Energy Technology Data Exchange (ETDEWEB)

As a method to make use of a high latent heat of a liquid-solid phase change material in a confined convective heat transfer, a phase change material, lauric acid, was encapsulated in a tiny hollow sphere, and mixed with water, forming a slurry of microencapsulated phase-change material (MCPCM slurry). Four different sizes (200, 100, 50, and 25 {mu}m ID) of MCPCMs were tested in this study. Thermal characteristics of the pure lauric acid and lauric acid MCPCMs were tested by a differential scanning calorimeter. Viscosity of the slurries of water and the capsules was measured by a rotating viscometer. The slurries were also tested in a convective-heat-transfer-test apparatus. (author). 11 refs., 5 figs., 1 tab.

1998-11-01

275

Canadian R&D on oil-fired combustion systems  

Energy Technology Data Exchange (ETDEWEB)

This paper describes research and development presently being conducted on oil-fired space and tap water heating systems by the Advanced Combustion Technology Group, CCRL/ERL/CANMET, in Ottawa, Canada. The presentation will focus on R&D activities at CCRL in support of the Canadian Oil Heat Association (COHA) and of the energy policy initiatives of Natural Resources Canada. Progress will be reported on activities to develop suitable oil-fired integrated systems to satisfy the low energy demands of new homes. The utilization of fuzzy logic-based control heating systems including fan coils for a complete range of old and new North American housing will be discussed. Additional activities to be discussed in the presentation will relate to the development of appropriate seasonal efficiency standards for complex integrated space/water heating systems, as well as ...

1996-07-01

276

Thermal-hydraulic limitations on water-cooled limiters  

Energy Technology Data Exchange (ETDEWEB)

An assessment of the cooling requirements for fusion reactor components, such as the first wall and limiter/divertor, was carried out using pressurized water as the coolant. In order to establish the coolant operating conditions, a survey of the literature on departure from nucleate boiling, critical heat flux, asymmetrical heating and heat transfer augmentation techniques was carried out. The experimental data and the empirical correlations indicate that thermal protection for the fusion reactor components based on current design concepts can be provided with an adequate margin of safety without resorting to either high coolant velocities, excessive coolant pressures, or heat transfer augmentation techniques. If, however, the future designs require heat transfer enhancement techniques, experimental verification would be necessary since no data on ...

1984-08-01

277

Thermal-hydraulic limitations on water-cooled fusion reactor components  

Energy Technology Data Exchange (ETDEWEB)

An assessment of the cooling requirements for fusion reactor components, such as the first wall and limiter/divertor, was carried out using pressurized water as the coolant. In order to establish the coolant operating conditions, a survey of the literature on departure from nucleate boiling, critical heat flux, asymmetrical heating and heat transfer augmentation techniques was carried out. The experimental data and the empirical correlations indicate that thermal protection for the fusion reactor components based on conventional design concepts can be provided with an adequate margin of safety without resorting to either high coolant velocities, excessive coolant pressures, or heat transfer augmentation techniques. If, however, the future designs require unconventional shapes or heat transfer enhancement techniques, experimental verification would be necessary ...

1986-01-01

278

Thermal-hydraulic limitations on water-cooled fusion reactor components  

Energy Technology Data Exchange (ETDEWEB)

An assessment of the cooling requirements for fusion reactor components, such as the first wall and limiter/divertor, was carried out using pressurized water as the coolant. In order to establish the coolant operating conditions, a survey of the literature on departure from nucleate boiling, critical heat flux, asymmetrical heating and heat transfer augmentation techniques was carried out. The experimental data and the empirical correlations indicate that thermal protection for the fusion reactor components based on conventional design concepts can be provided with an adequate margin of safety without resorting to either high coolant velocities, excessive coolant pressures, or heat transfer augmentation techniques. If, however, the future designs require unconventional shapes or heat transfer enhancement techniques, experimental verification would be necessary ...

1987-01-01

279

Thermal-hydraulic limitations on water-cooled fusion reactor components  

International Nuclear Information System (INIS)

An assessment of the cooling requirements for fusion reactor components, such as the first wall and limiter/divertor, was carried out using pressurized water as the coolant. In order to establish the coolant operating conditions, a survey of the literature on departure from nucleate boiling, critical heat flux, asymmetrical heating and heat transfer augmentation techniques was carried out. The experimental data and the empirical correlations indicate that thermal protection for the fusion reactor components based on conventional design concepts can be provided with an adequate margin of safety without resorting to either high coolant velocities, excessive coolant pressures, or heat transfer augmentation techniques. If, however, the future designs require unconventional shapes or heat transfer enhancement techniques, experimental verification would be necessary ...

1986-12-07

280

Use of solar assisted geothermal heat pump and small wind turbine systems for heating agricultural and residential buildings  

Energy Technology Data Exchange (ETDEWEB)

The main objective of the present study is twofold: (i) to analyze thermal loads of the geothermally and passively heated solar greenhouses; and (ii) to investigate wind energy utilization in greenhouse heating which is modeled as a hybrid solar assisted geothermal heat pump and a small wind turbine system which is separately installed in the Solar Energy Institute of Ege University, Izmir, Turkey. The study shows 3.13% of the total yearly electricity energy consumption of the modeled system (3568 kWh) or 12.53% of the total yearly electricity energy consumptions of secondary water pumping, brine pumping, and fan coil (892 kWh) can be met by using small wind turbine system (SWTS) theoretically. According to this result, modeled passive solar pre heating technique and combined with geothermal heat pump system (GHPS) and SWTS can be economically preferable to the ...

2010-01-15

281

Study of solution for issues of an optimum operating plan in heat storing system; Chikunetsu system ni okeru saiteki un`yo keikaku mondai no kaiho ni taisuru ichikosatsu  

Energy Technology Data Exchange (ETDEWEB)

An approximate solution was proposed in which a sensitivity analysis by the storage and release of heat was performed for the subject issues and in which an operating method was thereby determined for the equipment constituting the system by means of a linear programming. Accordingly, a heat storage type energy supply system for a district cooling and heating was taken up as a concrete object to be examined. This system consisted of a gas turbine generator, initial power receiving equipment, gas boiler, electric heat pump for ice heat storage, cooling tower, heat exchanger, steam absorbing refrigerating machine, ice heat storage tank, cold and warm water heat storage tank, etc. As a result of comparison between the proposed method and the resolving method, the former showed -0.92 to 2.58% in the ...

1996-02-01

282

Structural integrity of whipping pipes following a postulated circumferential break - a contribution to determining strain levels acceptable under faulted conditions  

Energy Technology Data Exchange (ETDEWEB)

It is postulated that a break of a thin-walled pipe does not cause a subsequent break in the pipe in the vicinity of a plastic hinge even when the wall is weakened by a 60 circumferential crack of a depth of 30% of the wall thickness on the tension side. This pipe behavior is the result of plastic buckling in the compression side and applies to pipes of diameter-to-thickness ratio larger than 20. For this type of pipe, the axial strains decrease with increasing diameter-to-thickness ratio in the tension side. As the pipe is only loaded in one direction, there is no cyclic behavior that can trigger a subsequent break. (orig.)

1993-10-01

283

Preliminary study of the effect of pumped-storage plant operation on zooplankton  

Energy Technology Data Exchange (ETDEWEB)

The hydromechanical effect of hydroelectric stations on zooplankton is customarily regarded as a constantly acting and comparatively harmless factor, since its destruction is inevitable when water masses are passed through hydroelectric stations, but its capacity for restoration is high (i.e., destruction of the zooplankton of the forebay is compensated by its production in the after bay). It is not known how correct such an opinion is, or what is the true balance of losses and reproduction of zooplankton in the forebays and after bays of hydroelectric stations. However, hydroelectric plants of a new type, pumped-storage plants, have been constructed in recent years and others are planned for the Dnieper reservoirs. The operational principle and purpose of these plants is that they employ special vertical turbine-electric pumps that pump water at night from the reservoirs into pumped-storage facilities at high levels, and then release this ...

1980-01-01

284

Emergency reactor core cooling device  

International Nuclear Information System (INIS)

The device of the present invention improves reactor safety by suppressing lowering of water level in a shroud which surrounds a reactor core, even upon occurrence of rupture of pipelines in an emergency reactor core cooling system in a recycling pump-incorporated type reactor. Namely, an opening of each of cooling systems which forms the emergency reactor core cooling device in a reactor pressure vessel is disposed above the upper end of the reactor core. Further, it also comprises an independent high pressure water injection system, gravitational dropping type water injection system and an automatic depressurization system. With such a constitution, even if rupture of pipelines in the system should be assumed, coolants never flow directly from the shroud which surrounds the reactor core. In addition, there are no pipelines to be ruptured below the upper end of the reactor core with respect to the structure. Accordingly, a ...

1993-03-16

285

Applications of cathodic protection for the protection of aqueous and soil corrosion of power plant components  

International Nuclear Information System (INIS)

Power plant components exposed to environments such as water and soil are susceptible to severe corrosion. Many times the effect of corrosion in power plant components can be catastrophic. The problem is aggravated for underground pipelines due to additional factors such as large network of pipelines, proximity to earth mat, high voltage transmission lines, corrosive chemicals, inadequate approach etc. Other components such as condenser water boxes, internals of pipelines, clarifier bridge structures, cooling water inlet gates and pipes etc. which are in continuous contact with water, are subjected to severe corrosion. The nature and locations of all such components are at places which are not accessible for routine maintenance and hence they require long term reliable protection against corrosion. Experience has shown that anti-corrosive coatings are inadequate in preventing ...

1999-11-22

286

Transient analysis of blowdown thrust force under PWR LOCA conditions  

Energy Technology Data Exchange (ETDEWEB)

The analytical results of blowdown characteristics and its thrust force were compared with the experiment, which were performed as pipe whip tests under the PWR LOCA conditions on the hypothetical accident of guillotine break of pipes. The blowdown thrust force was obtained by the integral momentum equation about single-phase flow, homogeneous and separated two-phase flow, assuming critical pressure at the exit if critical flow condition was satisfied. The following results are obtained: (1) The node-junction method is useful for the analysis of water hammer phenomena and of the blowdown thrust force. (2) The Henry-Fauske model for subcooled critical flow is effective for the analysis of the maximum thrust force under the PWR LOCA conditions. The jet thrust parameter of analysis and experiment is 1.08. (3) The thrust parameter of saturated blowdown has the same one with the value under pressurized condition when the ...

1982-09-01

287

Grouted pile study at Cranberry Jct: Nanticoke GS (generating station) - Longwood TS (transmission station)  

Energy Technology Data Exchange (ETDEWEB)

A field study was conducted in Ontario to evaluate the suitability of grouted piles for transmission tower foundations. The grouted piles were assessed in terms of the installation procedure and its foundation performance subjected to uplift loads. Two types of grouted piles, the H-pile and the pipe-pile, were evaluated and compared with conventional ungrouted H-pile foundations. Difficult soil conditions were encountered consisting of a deep deposit of loose to compact sand with a high water table. Both the grouted pipe-pile and the grouted H-pile developed uplift capacities more than double that of the conventional H-pile with the same embedment length at the test site. The grouted H-pile is recommended as a viable transmission line foundation in weak soils due to the significant improvement in its foundation performance, with minor modifications to the construction procedure. 3 refs., 17 figs., 12 tabs.

1990-09-28

288

Construction method of the artificial iced bobsleigh and luge track. Aiming at the Nagano Winter Olympic Games; Tekkin concrete sei bobsleigh luge track no kensetsu. Nagano Olympic toki kyogi taikai wo mezashite  

Energy Technology Data Exchange (ETDEWEB)

The reinforced concrete artificial iced course, constructed first in Japan as a bobsleigh and luge track for the Nagano Olympic Games, has a total extension of 1,700 m and an altitude difference of 113 m. It contains 15 curves and 2 up-grades and is divided into 43 blocks with spans ranging from 20 m to 80 m, all of which consist of lightwall RC members supported by pile foundations. The surface is cooled to -15 centigrade by the cooling pipes embedded in concrete and is iced by spraying water, and iced surface is shaved to make a course. Since the course scarcely has same profiles, the finished wall thickness is secured by fixing wire gauzes on the required positions without using shutterings. As there is not existed concrete satisfying all the required quality, two kinds of concrete were selected for filling in the arrangement of reinforcement and pipes and for surface finishing. Special notice was taken of the accuracy ...

1996-03-10

289

Prediction of thermal conductivity of ethylene glycol-water solutions by using artificial neural networks  

British Library Electronic Table of Contents (United Kingdom)

The objective of this study is to develop an artificial neural network (ANN) model to predict the thermal conductivity of ethylene glycol-water solutions based on experimentally measured variables. The thermal conductivity of solutions at different concentrations and various temperatures was measured using the cylindrical cell method that physical properties of the solution are being determined fills the annular space between two concentric cylinders. During the experiment, heat flows in the radial direction outwards through the test liquid filled in the annual gap to cooling water. In the steady state, conduction inside the cell was described by the Fourier equation in cylindrical coordinates, with boundary conditions corresponding to heat transfer between the solution and cooling water. ...

2009-01-01

290

Cheng cycle cogeneration system; Cheng cycle system cogeneration setsubi  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the Cheng cycle system featured by variable heating/generation ratio for effective operation of cogeneration systems (CGS). In this system, a superheater and reheating burner are added to an exhaust heat recovery (EHR) boiler for conventional gas turbine CGSs, while additional injection steam piping is attached to a gas turbine. Steam is injected through manifolds mounted on the periphery of a combustion chamber, and hot gas mixture of steam and air in a combustion chamber is expanded in a turbine and converted to motive power. This technology thus can improve efficiency and output power, and can operate variably CGSs corresponding to heating and generation demands. This technology has been promoted by introducing the technology of middle class Cheng cycle CGS with 4MW class gas turbine from IPT Co., U.S.A. The first system of 6400 kW is now under production for start of operation in ...

1996-03-29

291

Chemical process equipment for Hitachi. ; Featured equipment  

Energy Technology Data Exchange (ETDEWEB)

The present article describes the specialities in various chemical process equipment fabricated by Hitachi. It introduces the thin-film evaporator which heats, vaporizes and concentrates high viscosity fluid and slurry under thin-film conditions, the centrifugal extractor which uses a high speed rotating rotor to separate two kinds of immiscible liquids effectively in counter current contact conditions under a gravitational force ranging from 2,000G to 4,500G, the process gas boiler and heat pipe equipment which recovers exhausted heat effectively from various plants, the furnace and quench systems which are applied to olefin plants, EDC cracking and steam reforming, and the equipment which has been supplied to chemical plants operated under severe conditions, such as high temperature, high pressure and corrosive atmosphere. It was demonstrated that these technologies and know-hows accumulated from ...

1993-01-01

292

VACUJET-process - high pressure water jet technology with broad application potential; VACUJET-Verfahren - Wasserhoechstdrucktechnik mit grossem Einsatzpotential  

Energy Technology Data Exchange (ETDEWEB)

When performing trenchless pipe renovation work - whichever process you use - the success of the job depends on the careful removal of all scale, sediments and rust from the innerwall surfaces. The VACUJET process - in which the pipe is cleaned with water at pressures of up to 2 500 bar using a technique jointly developed by Preussag Rohrsanierung GmbH and Fabex GmbH - meets all requirements. The equipment includes a mobile waste water treatment unit which is small enough to fit on a standard trailer. Despite its compact dimensions this plant is so effective that it can treat all the waste water generated during the high pressure cleaning jobs so that it is suitable for reuse in the cleaning process or for release into the sewerage system. (orig.) [Deutsch] Bei der grabenlosen Rohrsanierung, ganz gleich nach welchem Verfahren saniert wird, ist die sorgfaeltige Entfernung von alten ...

1998-12-31

293

Study of the Energy Efficiency of the Melting Unit at the Rockwool Company Mineral Wool Process in Skoevde, Sweden.  

Science.gov (United States)

The melting unit, consisting of a water-cooled cupola furnace, afterburner, heat exchanger, air preheater, consumes most of the supplied energy in the rockwool process. The report maps the energy flows and defines factors of merit according to thermodynam...

1979-01-01

294

Solar desalination using humidification dehumidification processes. Pt. 1. A numerical investigation  

Energy Technology Data Exchange (ETDEWEB)

A numerical investigation of a humidification dehumidification desalination (HDD) process using solar energy is presented. The HDD system consists mainly of a concentrating solar water heating collector, flat plate solar air heating collector, humidifying tower and dehumidifying exchanger. Two separate circulating loops constitute the HDD system, the first for heating the feed water and the second for heating air. A mathematical model is developed, simulating the HDD system, to study the influence of the different system configurations, weather and operating conditions on the system productivity. The model validity is examined by comparing the theoretical and experimental results of the same authors. It is found that the results of the developed mathematical model are in good agreement with the experimental results and other published works. The results show ...

2004-05-01

295

Solar desalination using humidification dehumidification processes. Part I. A numerical investigation  

Energy Technology Data Exchange (ETDEWEB)

A numerical investigation of a humidification dehumidification desalination (HDD) process using solar energy is presented. The HDD system consists mainly of a concentrating solar water heating collector, flat plate solar air heating collector, humidifying tower and dehumidifying exchanger. Two separate circulating loops constitute the HDD system, the first for heating the feed water and the second for heating air. A mathematical model is developed, simulating the HDD system, to study the influence of the different system configurations, weather and operating conditions on the system productivity. The model validity is examined by comparing the theoretical and experimental results of the same authors. It is found that the results of the developed mathematical model are in good agreement with the experimental results and other published works. The results show ...

2004-05-01

296

Resuscitation of Salmonella enterica Serovar Typhimurium and Enterohemorrhagic Escherichia coli from the Viable but Nonculturable State by Heat-Stable Enterobacterial Autoinducer  

UK PubMed Central (United Kingdom)

Salmonella enterica serovar Typhimurium and enterohemorrhagic Escherichia coli were stressed by prolonged incubation in water microcosms until it was no longer possible...Full Text Available

2002-10-01

297

Resistance of Bacillus subtilis var. niger Spores Occluded in Water-insoluble Crystals to Three Sterilization Agents  

UK PubMed Central (United Kingdom)

The resistance to destruction of spores of Bacillus subtilis var. niger occluded in crystals of calcium carbonate and exposed to ethylene oxide and moist and dry heat...Full Text Available

1967-07-01

298

Environmental effects and energy efficiency in building design: A green building approach. Part 1, energy efficiency techniques. Research report  

Energy Technology Data Exchange (ETDEWEB)

;Contents: Energy Use; Building Fabric Performance; Ventilation and Infiltration; Passive Solar Design; Heating Systems and Controls; Hot and Cold Water Provision; and Lighting and Electrical Appliances.

1993-01-01

299

Environmental Effects and Energy Efficiency in Building Design: A Green Building Approach. Part 1, Energy Efficiency Techniques.  

Science.gov (United States)

Contents: Energy Use; Building Fabric Performance; Ventilation and Infiltration; Passive Solar Design; Heating Systems and Controls; Hot and Cold Water Provision; and Lighting and Electrical Appliances.

1993-01-01

300

40 CFR 63.321 - Definitions.  

Science.gov (United States)

...limited to, emission control devices, pumps, filters, muck cookers, stills, solvent tanks, solvent containers, water separators...facility that meets the conditions of § 63.320(g). Muck cooker means a device for heating perchloroethylene-laden...

2009-07-01

301

Safety System Design Concept and Performance Evaluation for a Long Operating Cycle Simplified Boiling Water Reactor  

Science.gov (United States)

The long operating cycle simplified boiling water reactor is a reactor concept that pursues both safety and the economy by employing a natural circulation reactor core without a refueling, a passive decay heat removal, and an integrated building for the reactor and turbine. Throughout the entire spectrum of the design basis accident, the reactor core is kept covered by the passive emergency core cooling system. The decay heat is removed by the conventional active low-pressure residual heat removal system. As for a postulated severe accident, the suppression pool water floods the lower part of the reactor pressure vessel (RPV) in the case when core damage occurs, and the in-vessel retention that keeps the melt inside the RPV is achieved by supplying the coolant. The containment adopts a parallel-double-steel-plate structure similar to a hull structure, which contains coolant between ...

2003-07-15

302

Piping response testing associated with pipe rupture  

Energy Technology Data Exchange (ETDEWEB)

EPRI has sponsored an experimental program in the pipe whip impact and pipe rupture and depressurization areas. Sixteen pipe whip tests were performed with 3 in Schedule 80 (or 10) carbon steel pipes impacting on rigid target or concrete slab. The major testing parameters include distance, impact location, pipe rupture location, and concrete slab thickness and strength. The piping crushing at impact correlates with impact force and target response behavior. Conservatism was established by comparing measured and calculated impact forces. The pipe rupture and depressurization tests were carried out using 6 in stainless steel and carbon steel pipes under either PWR or BWR fluid conditions. These tests are of axial crack with initial machined-in surface flaw. It was found that pipe rupture would occur ...

1985-11-01

303

Reliability analysis of stiff versus flexible piping. Status report  

Energy Technology Data Exchange (ETDEWEB)

Conservative design procedures adopted for nuclear piping systems usually result in stiff piping designs that use excessive support devices such as rigid supports and snubbers. Use of these piping support devices has created safety concerns. This report describes the interim result for a piping research project conducted at Lawrence Livermore National Laboratory (LLNL) for the US Nuclear Regulatory Commission (NRC). The overall objective of this research project is to develop modified design requirements and criteria which will improve piping reliability and minimize the use of pipe supports, snubbers, and pipe whip restraints. The current study was conducted to establish the necessary groundwork for this work based on the piping reliability analysis.

1984-04-01

304

Experimental and analytical studies of four-inch pipe whip tests under PWR LOCA conditions  

Energy Technology Data Exchange (ETDEWEB)

This paper presents experimental and analytical results of pipe whip tests performed under PWR LOCA conditions using a test pipe of 4-inch diameter and U-shaped restraints. In the tests, the effects of the overhang length on the pipe whip behavior of the piperestraints system were studied by measuring the strains and deformations of the test pipe and restraints, and the restraints forces. The equation for predicting the maximum strain at the outer surface of the pipe was derived using a static equilibrium condition. The calculated maximum strains at the outer surface of the pipe agree fairly well with experimental data. The dynamic response analysis of the pipe-restraints system was conducted by the finite element program ADINA. The applicability of the ADINA program to the pipe whip analysis is made clear through this ...

1984-01-01

305

Dynamic response analysis of pipe-restraints system. Analysis of pipe whip tests performed under PWR-LOCA conditions using 4-inch test pipe  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the results of the dynamic response analysis of the pipe-restraints system by the general purpose finite element program ADINA. The analysis was carried out for the pipe whip tests performed under the PWR-LOCA conditions using 4-in. test pipe. In the analysis, the test pipe was modeled by an assemblage of the beam elements with the isotropic elastic-plastic material properties and the restraints were represented by the truss elements with the nonlinear elastic material properties including gap effect. The following results are obtained through the analysis. (1) Pipe can be modeled with the beam elements, when the overhang length is short and, therefore, the flattening of a cross-section of pipe is small. (2) The steady state restraint force can be predicted by modeling the restraints with the truss elements.

1983-09-01

306

Determination of critical length for pipe whip design  

Energy Technology Data Exchange (ETDEWEB)

Design of pipe whip restraints requires a knowledge of the maximum allowable unsupported pipe length. This paper presents a numerical method for calculating this critical length of the pipe. Salient features of the method are: (1) as a flow rounds an elbow, it exerts a transverse kick and an axial thrust to the pipe, both the axial thrust and the bending moment are considered; (2) the jet force is applied in an abrupt manner, the dynamic amplification factor (DAF) is determined from the load-deflection (H-{Delta}) curve of the pipe, by taking into consideration large strain, large deformation and the nonlinear stress-strain relationship of the piping material; (3) the ultimate capacity of the pipe under the combined action of an axial force and a bending moment is governed by an interaction formula. The maximum unsupported ...

1995-11-01

307

A study on the experimental verification for the pipe whip problem in a Nuclear Power Plant  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to investigate on the experimental verification analysis for the pipe whip problems and to obtain the quantitative evaluation technologies for the design technique of pipe whip restraints. These will contribute to the advance of nuclear regulatory technologies and enhance nuclear power plant safety. This study presents the experimental and transient analytical results of pipe whip tests using the 4', 6' diameter pipe and U-shaped restraints. In the tests, the effects of the overhang length, clearance, impact height on the pipe whip behavior of the pipe-restraints were investigated. The transient impact analysis of the pipe-restraint system was conducted by the finite element program ABAQUS. The applicability of the ABAQUS program to the pipe whip analysis is made clear ...

1993-12-15

308

Post-CHF heat transfer with water and refrigerants  

Energy Technology Data Exchange (ETDEWEB)

Heat transfer experiments were performed in the post-CHF two-phase flow regime in a vertical tube. The tube inside diameter was 7.75 mm, and the boiling fluid was R-113. The experiments were performed at steady state by means of liquid heating of the test tube. Wall superheats were maintained below 70 C for heat exchanger/steam generator application. The mass flux range of the data was 379-816 kg m{sup -2} s{sup -1}. The use of R-113 significantly extended the property range of the existing low wall-superheat data base. Experimental data are presented in tabular as well as graphical form, and the results were used with low wall-superheat data from other fluids to add generality to a predictive heat transfer correlation. (orig.)

1996-06-01

309

On the anatomy of the adsorption heat versus loading as a function of temperature and adsorbate for a graphitic surface  

British Library Electronic Table of Contents (United Kingdom)

In this paper we review and classify the various patterns of isosteric heat versus loading for adsorption of gases on graphitised thermal carbon black at temperatures ranging from below the 3D triple point to temperatures above it, but less than the 3D critical point. We have identified the features of heat curve and highlighted the microscopic origin of these features. The patterns vary with temperature and with the relative strength of the fluid-fluid interaction and solid-fluid interaction. For simple adsorptives (by simple we meant there is no strong association between fluid particles), the heat curve is typified by fluid-fluid attraction and layering phenomena. For adsorptives showing strong association such as water, ammonia and methanol, the heat curve essentially begins below the ...

2008-01-01

310

Materials selection for the US INTOR divertor collector plate  

Energy Technology Data Exchange (ETDEWEB)

The divertor collector plate in the INTOR reactor will be subjected to high heat, particle, and neutron fluxes, making it the most severely damaged torus component. The collector plate is composed of a protection plate, which is directly exposed to the particle flux, and a heat sink which provides support for the protection plate and carries the water coolant. The high-Z refractory metals have been considered for use as the protection plate material, and austenitic stainless steels and copper alloys have been considered as the heat sink material. Tungsten and Type 316 stainless steels have been selected for the protection plate and heat sink, respectively. The protection plate has a sputtering lifetime of 1.75 y at a 50% duty factor, while the heat sink is expected to last the lifetime of the reactor.

1981-01-01

311

Reducing the breakdowns and energy consumption in pressure regulating stations by rationalizing the heating of gas  

Energy Technology Data Exchange (ETDEWEB)

Sigma 1) examines ways to reduce the number of breakdowns of pressure-regulating stations and to minimize the energy consumed in warming the gas, 2) determines the optimal gas temperatures upstream from the pressure reduction, and 3) shows the dependence of energy consumption upon the water dewpoint. The method of calculating the optimal input temperature relies on Mollier's diagram. Tables and nomographs for natural gas and water dewpoint at 19/sup 0/F and 580 psi (-7/sup 0/C and 4 MPa) are useful in achieving the desired gas temperatures. Heating the regulators' control valves is important.

1982-04-01

312

Thermal energy storage system using stearic acid as a phase change material  

Energy Technology Data Exchange (ETDEWEB)

The thermal performance and phase change stability of stearic acid as a latent heat energy storage material has been studied experimentally. The thermal performance and heat transfer characteristics of the stearic acid were tested and compared with other studies given in the literature. In the present study, parameters such as transition times, temperature range and propagation of the solid-liquid interface as well as the effect of heat flow rate on the phase change stability of stearic acid as a phase change material (PCM) were studied. The experimental results showed that the melting stability of the PCM is better in the radial direction than in the axial direction. The variation in the melting and solidification parameters of the PCM with the change of inlet water temperature is also studied. We observed that while the heat exchanger tube is in the horizontal position, the PCM ...

2001-07-01

313

Some properties of atomic beam produced by laser induced ablation of Li target  

International Nuclear Information System (INIS)

Pulsed atomic beams produced in vacuum by laser induced ablation from a lithium target are analyzed by laser induced fluorescence (LIF). The 1-mixing processes induced in the n = 9, 10 Li Rydberg states by collisions with CO_2 molecules illustrate the application of the method. Resolution is limited by the 1 mm diameter of the probe laser beam. Combining LIF and absorption measurements gives n_L_i as a function of time at various distances from the target surface. The investigation of the Li-C0_2 1-mixing process in a heat pipe oven proved impossible due to the high reactivity of Li with C0_2. This problem was solved by renewing the Li atoms at each laser shot. Values obtained for n = 9, n = 10 are k = 17 x 10"-"8 and 15 x 10"-"8 cc/sec, respectively.

314

Investigations for judging the working behaviour of components made of alloy 800 and alloy 617 under creep stress. Untersuchungen zur Beurteilung des Betriebsverhaltens kriechbeanspruchter Bauteile aus Alloy 800 und Alloy 617  

Energy Technology Data Exchange (ETDEWEB)

The program introduced here for determining and describing the multi-axial creep of pipes is based, on the one hand, on the results of the nuclear process heat prototype plant material program and, on the other hand, on the possible load conditions which arise for evaluating accidents or extreme working situations. The basis of a theoretical description of multi-axial creep is the invariant theory in which both the von Mises configuration change hypothesis and the Norton creep law are included. Combined tension and torsion are also considered in detail, the superimposition of cyclic stresses in the tensile threshold area is discussed and cases of partial relaxation are explained. Experimental results for the discussed loads are introduced, which have led to satisfactory agreement between theory and experiment. (orig./MM).

1987-01-01

315

Investigations for judging the working behaviour of components made of alloy 800 and alloy 617 under creep stress  

International Nuclear Information System (INIS)

The program introduced here for determining and describing the multi-axial creep of pipes is based, on the one hand, on the results of the nuclear process heat prototype plant material program and, on the other hand, on the possible load conditions which arise for evaluating accidents or extreme working situations. The basis of a theoretical description of multi-axial creep is the invariant theory in which both the von Mises configuration change hypothesis and the Norton creep law are included. Combined tension and torsion are also considered in detail, the superimposition of cyclic stresses in the tensile threshold area is discussed and cases of partial relaxation are explained. Experimental results for the discussed loads are introduced, which have led to satisfactory agreement between theory and experiment. (orig./MM).

1987-11-27

316

Doppler-free optogalvanic spectroscopy of sup(88,86)Sr I and II  

International Nuclear Information System (INIS)

We have measured the isotope shifts of some dipole transitions between excited states of the even strontium isotopes 88 and 86 by applying the technique of Doppler-free intermodulated optogalvanic spectrocopy to a heat-pipe discharge. We were also able to investigate the isotope shift of the Sr II resonance line at 4216.6 A optogalvanically in the mentioned pair of isotopes. Because the 5 snf"1F_3 series appear to have zero level isotope shifts for n>=6, we can give residual level isotope shifts (RLIS) of several odd-parity states of sup(88,86) Sr I. The RLIS of the 5 snp "1P_1 series show pronounced configuration mixing around n=7. (orig.).

317

Application of automatic inspection system to nondestructive test of heat transfer tubes of primary pressurized water cooler in the high temperature engineering test reactor. Joint research  

International Nuclear Information System (INIS)

Heat transfer tubes of a primary pressurized water cooled (PPWC) in the high temperature engineering test reactor (HTTR) form the reactor pressure boundary of the primary coolant, therefore are important from the viewpoint of safety. To establish inspection techniques for the heat transfer tubes of the PPWC, an automatic inspection system was developed. The system employs a bobbin coil probe, a rotating probe for eddy current testing (ECT) and a rotating probe for ultrasonic testing (UT). Nondestructive test of a half of the heat transfer tubes of the PPWC was carried out by the automatic inspection system during reactor shutdown period of the HTTR (about 55% in the maximum reactor power in this paper). The nondestructive test results showed that the maximum signal-to-noise ratio was 1.8 in ECT. Pattern and phase of Lissajous wave, which were obtained for the heat transfer tube of ...

318

The effect of welding processing on the creep strength of heat-resistant chromium/molybdenum/vanadium alloyed pipe steels; Einfluss der schweisstechnischen Verarbeitung auf die Zeitstandfestigkeit warmfester Chrom-Molybdaen-Vanadium-legierter Rohrstaehle  

Energy Technology Data Exchange (ETDEWEB)

This is a report on the results of creep tests of large extent on samples of welded joints. The possibilities of minimising the reduction in creep strength which occurs are also shown. The range of the pipe welded joints examined extends from superheater pipes 31.8 diam x 5 mm to hot steam pipelines 240 diam x 29 mm. The steels used are: X 20 CrMoV 12-1, X 10 CrMoVNb 9-1 and X 10 CrWMoVnB 9-2. (orig./MM) [Deutsch] Es wird ueber Ergebnisse von in groesserem Umfang laufenden Zeitstandversuchen an Proben aus Schweissverbindungen berichtet. Ausserdem werden Moeglichkeiten aufgezeigt, den eintretenden Zeitstandfestigkeitsabfall zu minimieren. Die Spanne der in Untersuchung befindlichen Rohrschweissverbindungen reicht dabei vom Ueberhitzerrohr diameter 31,8 x 5 mm bis zum Heissdampfleitungsrohr diameter 240 x 29 mm. Die verwendeten Staehle sind: X 20 CrMoV 12 -1; X 10 CrMoVnB 9-1; X 10 CrWMoVnb 9-2. (orig./MM)

1995-12-31

319

Selecting the Design Entering Water Temperature for Vertical Geothermal Heat Pumps in Cooling-Dominated Applications  

International Nuclear Information System (INIS)

At a military base in the Southeastern US, an energy services company (ESCO) has proposed to retrofit more than 1,000 family residences with geothermal heat pumps as part of an energy savings performance contract (ESPC). Each residence is to have one heat pump with its own ground heat exchanger consisting of two or more vertical bores. A design firm hired by the ESCO sized the heat pumps to meet peak cooling loads, and sized the borefields to limit the maximum entering water temperature (EWT) to the heat pumps to 95 F (35 C). Because there is some disagreement in the geothermal heat pump industry over the peak temperature to be used for design (some designers and design manuals recommend temperatures as low as 85 F[29 C], while equipment manufacturers and others specify temperatures of 100 F[38 C] or higher) the authors were requested to ...

320

Radisson community heating systems: technical and economic comparison of options. Final report  

Energy Technology Data Exchange (ETDEWEB)

The study reported was conducted to evaluate water source community heat pump systems for possible installation to serve a number of homes which are to be constructed in the northeast section of Radisson, New York. Although specific sites and facilities have been evaluated, it is the intent of this study to be site specific only to the extent of climatic conditions. In other words, the results of this study should apply to any area with similar climate.

1981-12-01

321

On the feedwater heating in a steam generator of horizontal type  

International Nuclear Information System (INIS)

Design layout of horizontal steam generator (SJ) with a special feedwater heating surface (by a surface water economizer), designated for NPPs with WWER-1000 reactors, is suggested. The design enables to decrease sharply the difference between the temperatures of saturation and feedwater. Blowdown outlet is organized against PG face, which increases the efficiency of flowing. The suggested layout enables to decrease thermal stresses in structural units and PG metal content, as compared to the PGV-1000 steam generator.

1989-01-01

322

Markets for clean energy  

Wastenet

... The products can be categorised as glazed flat-plate collectors, evacuated glass-tube collectors, and unglazed plastic or low temperature collectors. Glazed flat-plate collectors and vacuum tubes are widely used for solar water heating and space heating systems in all types of buildings. Unglazed plastic collectors are used exclusively for lower temperature applications, such as outdoor swimming pools or the agrarian business. Flat-plate solar collectors are likely to ...

323

Guide to UK renewable energy companies 2001. 6. ed.  

International Nuclear Information System (INIS)

This 2001 edition of the guide to UK renewable companies and equipment and service providers presents summaries of the different industry sectors covering wind power, photovoltaics, solar water heating, geothermal heat pump, hydroelectric power, marine current and wave technology, bioenergy, power generation from landfill gas, energy from waste, and cogeneration. A UK company classification listing and index is provided along with listing of UK organisations and companies and an index of advertisers.

324

A method of producing a stabilizer of wash drilling muds  

Energy Technology Data Exchange (ETDEWEB)

A method is proposed for producing a stabilizer of wash drilling muds; by hydrolysis of polyacrylonitrile in an aqueous solution of alkaline agent with heating. To raise the heat resistance of the stabilizer, as the alkaline agent is used monosilicate of sodium, while the hydrolysis is done at a molar ratio of polyacrylonitrile, sodium monosilicate and water equal to 1.0:0.7-2.5:100, to a degree of hydrolysis of 25-40.

1981-01-01

325

Radiant heating and cooling, displacement ventilation with heat recovery and storm water cooling: An environmentally responsible HVAC system  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the design, operation, and performance of an HVAC system installed as part of a project to demonstrate energy efficiency and environmental responsibility in commercial buildings. The systems installed in the 2180 m{sup 2} office building provide superior air quality and thermal comfort while requiring only half the electrical energy of conventional systems primarily because of the hydronic heating and cooling system. Gas use for the building is higher than expected because of longer operating hours and poor performance of the boiler/absorption chiller.

1998-12-31

326

Mixed convection flow in a horizontal rectangular channel subjected to a horizontal thermal gradient  

British Library Electronic Table of Contents (United Kingdom)

This paper deals with a mixed convection water flow in a horizontal rectangular duct, uniformly heated from one lateral vertical wall and thermally insulated elsewhere. The supplied heat flux induces a secondary flow, which structure is constituted of one longitudinal roll in the considered aspect ratio (??=?1.9), embedded into a return flow of possibly large stream wise extension (up to twenty channel heights). Such situation induces helicoidal trajectories for the fluid flow particles, which contributes to a heat transfer enhancement compared to purely forced convection flow.

2011-01-01

327

Mixed convection flow in a horizontal rectangular channel subjected to a horizontal thermal gradient  

Science.gov (United States)

This paper deals with a mixed convection water flow in a horizontal rectangular duct, uniformly heated from one lateral vertical wall and thermally insulated elsewhere. The supplied heat flux induces a secondary flow, which structure is constituted of one longitudinal roll in the considered aspect ratio (? = 1.9), embedded into a return flow of possibly large stream wise extension (up to twenty channel heights). Such situation induces helicoidal trajectories for the fluid flow particles, which contributes to a heat transfer enhancement compared to purely forced convection flow.

2011-04-01

328

Application of the porous media model for the LWR process components  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: A porous media solution PORFLO has been developed for the 3-dimensional two-phase flow by describing the process facility in Cartesian or cylindrical coordinates. The local porosity fraction is applied for distinguishing the fluid filled volumes from the solid structures. The solid structure contribute the two-phase flow through the wall friction, flow area and heat transfer. Optionally the solid structure may contain primary liquid of steam generators, steam in the higher temperature and pressure to be condensed or electrical heating power. By using these optional boundary conditions three different process facilities have been analysed. The thermohydraulic solution based on 5-equation approach, where the conservation equations are solved for the liquid and gas (vapour) mass, mixture momentum (giving the velocity only for the mixture), liquid and gas energy, is described shortly. In addition to that the ...

2005-07-01

329

Numerical study on the heat transfer to CO_2 flowing upward in a heated vertical tube at supercritical pressure  

International Nuclear Information System (INIS)

Full text of publication follows: As the coolant experiences no phase change in the core, SCWRs, unlike LWRs, cannot use design criteria based on the critical heat flux concept. The commonly accepted practice in SCWRs is to specify cladding temperature limits that must be met during transient and accident events. Therefore for the design of the SCWR, it is very important to predict the heat transfer coefficient to the supercritical water coolant with great accuracy. Our recent study focuses on the critical issue of measuring heat transfer to supercritical water at prototypical SCWR conditions and to develop the tools to predict the SCWR thermal behavior. A heat transfer test loop using a surrogate fluids, CO_2, is under construction. The reason of using CO_2 instead of water is that (i) valuable insight of the physical phenomena can be ...

2005-10-02

330

Two-phase flow regime observations in a vertical hexagonal flow channel with and without a finned fuel bundle  

International Nuclear Information System (INIS)

Previous flow regime studies have been for horizontal, vertical, and inclined pipe flow. As such, only a few studies have been performed on bundle geometries. The present paper examines the flow regimes for a vertical hexagonal flow channel with and without a finned fuel bundle. This type of a 36 finned rod hexagonal fuel bundle in parallel hexagonal flow channels is used in a MAPLE (Multi- purpose Applied Physics Lattice Experimental) type nuclear reactor. An experiment apparatus was designed consisting of the flow channel, inlet plenum and an air-water separator. The inlet plenum is used to provide a uniform mixture of air and water before entering the hexagonal flow channel. A turbine flow meter is used to determine the water flow rate. The turbine flow meter is calibrated for a low flow range and limits the measurable flow to 50 l/min. Flow pattern observation is determined by a SONY video camera, ...

1990-12-10

331

Structural analysis of piping after a large pipe break in a WWER-440 type reactor  

International Nuclear Information System (INIS)

In the WWER-440 reactor the primary piping consists of six horizontal loops going radially from the pressure vessel, each loop having a horizontal steam generator. In this reactor type the relatively long primary piping with many curved sections requires special attention in order to successfully eliminate the consequences of the design basis accident. Emergency supports are located in appropriate places to restrict the movements of the pipe in 1, 2, 3 or 4 directions depending on the geometry of the pipe near the support. Under normal conditions there is a gap of some centimeters between the pipe and a support so that the pipe can be deformed freely under changing loads. In order to analyse the behaviour of the broken piping system with the support structures a computer code called PIPEBREAK has been written. The main objects in the ...

1975-09-01

332

Performance of Buried Pipe Installations, Summary.  

Science.gov (United States)

The goal of this research project was to determine the eff ects of geometric and mechanical parameters characterizing the soil-structure interaction developed in a buried pipe installation. Parameters such as pipe ring stiff ness, bedding thickness, trenc...

2010-01-01

333

Method of pipe whip and impact analyses  

Energy Technology Data Exchange (ETDEWEB)

We successfully reproduce one of the French pipe whip experiments with the computer code WIPS. The WIPS results are in excellent agreement with the experimental data and the French computer code TEDEL. This justifies the use of its pipe element in conjunction with its U-bar element in a simplified method of impact analyses.

1983-11-21

334

Transient burnout in flow reduction condition  

International Nuclear Information System (INIS)

A transient flow reduction burnout experiment was conducted with water in a uniformly heated, vertically oriented tube. Test pressures ranged from 0.5 to 3.9 MPa. An analytical method was developed to obtain transient burnout conditions at the exit. A simple correlation to predict the deviation of the transient burnout mass velocity at the tube exit from the steady state mass velocity obtained as a function of steam-water density ratio and flow reduction rate. The correlation was also compared with the other data. (author).

335

Means for deriving hydrolized polyacrylonitrile  

Energy Technology Data Exchange (ETDEWEB)

A method is proposed for deriving hydrolized polyacrylonitrile from a water-based alkali solution. This process is meant to improve the thermal stability of clay drilling solutions by employing the hydrolized product to treat aliphatic non-water-soluble C/sub 8/-C/sub 16/ spirits in an organic dispersant during the presence of acidity and while the solution is being heated.

1982-01-01

336

Direct measurements of secondary water inventory of steam generator PGV-213 in operation  

Energy Technology Data Exchange (ETDEWEB)

Results of weight measurement of PGV-213 steam generator during filling in, heating-up and power increase are described. Special measurement system based on stress gauges has been developed. Method of derivation of secondary water inventory is described. Comparison of the data for two steam generators prove accuracy of the measurements. (orig.). 1 refs.

1997-12-31

337

Climates of the oceans  

Energy Technology Data Exchange (ETDEWEB)

''Climates of the Oceans'' deals with the atmosphere over the world oceans and provides a treatment not only of the climatic elements such as temperature, pressure, wind, precipitation etc., but also of the circulation of the atmosphere and its changes throughout the year. The connection between sea and overlying air is examined through studies of the water and heat balance. Numerous maps and tables illustrate the elements and their fluctuations over the water and on islands and coasts.

1984-01-01

338

Technical-economic aspects of the utilization of geothermal waters  

International Nuclear Information System (INIS)

A brief description is given of the physico-chemical parameters characterized a hot water geothermal reservoir and of its exploitation by means of single or coupled (doublet) wells. The technical aspects of geothermal heat to the users is then discussed, beginning with corrosion of materials caused by seven main agents: oxygen, hydrogen sulphide, carbon dioxide, ammonia, hydrogen, sulphates and chlorides. A brief mention is made of scaling due to calcium carbonate, silica and calcium sulphates. The basic components of a geothermal plant for non-electric uses are then discussed: production pumps, surface pipelines, heat exchangers, heat pumps and reinjection pumps. The advantages and disadvantages of the different equipment and materials used in the geothermal sector are also presented. A list is also given of the criteria used in the energy and economic balance of a geothermal operation. (author). 24 ...

339

Market assessment for the fan atomized oil burner  

Energy Technology Data Exchange (ETDEWEB)

The market potential for the fan atomized burner (FAB) in water and space heating applications was examined. The major findings of the study are as follows. (1). The FAB`s low-input capability allows development of oil-fired room heaters and wall furnaces, a new market area for oil heat. (2). Among conventional oil-fired products, furnaces will benefit most from the burner`s low input capability due to (1) their quick delivery of heat and (2) their more prevalent use in warmer climates and smaller homes. (3). The greatest potential for increased product sales or oil sales exists in the use of the burner with new products (i.e., room heaters). Sales of boilers and direct-fired water heaters are not likely to increase with the use of the burner. (4). Acceptance of the burner will be dependent on proof of reliability. Proof of better reliability than conventional burners would ...

1996-07-01

340

Interface heat transfer of horizontal co-current liquid-liquid stratified flow  

International Nuclear Information System (INIS)

Co-current stratified flow of liquid metal and water was investigated in a horizontal rectangular channel. Position of the interface pressure drop and direct contact heat transfer between these immisci ble liquids were measured in a fully developed flow. A turbulence model was proposed to explain the experimental results considering that the turbulence is damped near the liquid-liquid interface by surface tension. The analytical results showed good agreement with the experimental ones. Main results are that (1) position of the interface mainly depends on the flow rate ratio of both liquids, that (2) the pressure drop is approximately proportional to square of the average velocity of water, and that (3) heat transfer rate at direct contact interface is several times higher than that of co-current flow separated by a thin solid plate. (author).

1980-01-01

341

Safety design guide for pipe rupture protection for CANDU 9  

Energy Technology Data Exchange (ETDEWEB)

This safety design guide for pipe rupture protection identifies high-energy systems in which pipe ruptures must be postulated to occur, as well as systems that must be protected from the dynamic effects of such ruptures. Dynamic effects considered in this SDG consist of pipe whip (including missiles generated by pipe ruptures, if any) and jet impingement, Requirements for protection against the dynamic effects of a postulated pipe rupture and method of protection of essential structures, systems and components are specified for these effects. The change status for the regulatory requirements, code and standards should be traced and this safety design guide shall be updated accordingly. 2 tabs., 5 refs. (Author) .new.

1996-03-01

342

Three Dimensional Visualization for the Steam Injection into Water Pool using Electrical Resistance Tomography  

International Nuclear Information System (INIS)

The direct injection of steam into a water pool is a method of heat transfer used in many process industries. The amount of research in this area however is limited to the nuclear industry, with applications relating to reactor cooling systems. Electrical resistance tomography (ERT), a low cost, non-invasive and which has high temporal resolution characteristics, can be used as a visualization tool for the resistivity distribution for the steam injection into water pool such as IRWST. In this paper, three dimensional resistivity distribution of the process is obtained through ERT using iterative Gauss-Newton method. Numerical experiments are performed by assuming different resistive objects in the water pool. Numerical results show that ERT is successful in estimating the resistivity distribution for the injection of steam in the water pool

2010-10-01

343

The effect of a concurrent gas flow on gas-liquid mass transfer  

Science.gov (United States)

A theory for the mass transfer process was developed. It was assumed that the largest convective motions in the flow control the rate of mass transfer. Measurements of mass transfer coefficients for the absorption of oxygen by water films were made for concurrent flows in a horizontal rectangular channel, and for concurrent and free-falling downflow in a one-inch pipe. The measured values of the Sherwood number for concurrent flows were up to three times as great as would be predicted from this relation. This increase in Sherwood number was correlated with a dimensionless group similar to a Martinelli parameter which is characteristic of two phase flows. An explanation for this effect is given in terms of the way that the scales of the convective motions are related to bulk flow parameters.

1977-01-01

344

Influence of gully erosion control on amphibian and reptile communities within riparian zones of channelized streams  

British Library Electronic Table of Contents (United Kingdom)

Riparian zones of streams in northwestern Mississippi have been impacted by agriculture, channelization, channel incision, and gully erosion. Riparian gully formation has resulted in the fragmentation of remnant riparian zones within agricultural watersheds. One widely used conservation practice for controlling gully erosion is the installation of drop pipes. This practice involves placing earthen dams across eroding gullies and embedding a metal standpipe within the dam to convey water from the field to stream level. Installation of this structure halts gully erosion and incidentally replaces eroding gullies with riparian habitats. Previous research evaluating gully erosion control structures have not considered the ecological impacts of these conservation practices on amphibian and repti...

2009-01-01

345

Estimating pressurized water reactor decommissioning costs: A user`s manual for the PWR Cost Estimating Computer Program (CECP) software. Draft report for comment  

Energy Technology Data Exchange (ETDEWEB)

With the issuance of the Decommissioning Rule (July 27, 1988), nuclear power plant licensees are required to submit to the US Regulatory Commission (NRC) for review, decommissioning plans and cost estimates. This user`s manual and the accompanying Cost Estimating Computer Program (CECP) software provide a cost-calculating methodology to the NRC staff that will assist them in assessing the adequacy of the licensee submittals. The CECP, designed to be used on a personnel computer, provides estimates for the cost of decommissioning PWR plant stations to the point of license termination. Such cost estimates include component, piping, and equipment removal costs; packaging costs; decontamination costs; transportation costs; burial costs; and manpower costs. In addition to costs, the CECP also calculates burial volumes, person-hours, crew-hours, and exposure person-hours associated with decommissioning.

1993-10-01

346

A two-phase flow regime map for a MAPLE-type nuclear research reactor fuel channel: Effect of hexagonal finned bundle  

Energy Technology Data Exchange (ETDEWEB)

A two-phase flow regime map is developed experimentally and theoretically for a vertical hexagonal flow channel with and without a 36-finned rod hexagonal bundle. This type of flow channel is of interest to MAPLE-type nuclear research reactors. The flow regime maps are determined by visual observations and observation of waveforms shown by a capacitance-type void fraction meter. The experimental results show that the inclusion of the finned hexagonal bundle shifts the flow regime transition boundaries toward higher water flow rates. Existing flow regime maps based on pipe flow require slight modifications when applied to the hexagonal flow channel with and without a MAPLE-type finned hexagonal bundle. The proposed theoretical model agrees well with experimental results.

1997-05-01

347

A two-phase flow regime map for a MAPLE-type nuclear research reactor fuel channel: Effect of hexagonal finned bundle  

International Nuclear Information System (INIS)

A two-phase flow regime map is developed experimentally and theoretically for a vertical hexagonal flow channel with and without a 36-finned rod hexagonal bundle. This type of flow channel is of interest to MAPLE-type nuclear research reactors. The flow regime maps are determined by visual observations and observation of waveforms shown by a capacitance-type void fraction meter. The experimental results show that the inclusion of the finned hexagonal bundle shifts the flow regime transition boundaries toward higher water flow rates. Existing flow regime maps based on pipe flow require slight modifications when applied to the hexagonal flow channel with and without a MAPLE-type finned hexagonal bundle. The proposed theoretical model agrees well with experimental results.

1997-01-01

348

Pitting corrosion of copper and copper alloys. (Latest citations from the Metals Abstracts alloys index database). Published Search  

Energy Technology Data Exchange (ETDEWEB)

The bibliography contains citations concerning the pitting corrosion of copper and copper alloys, in different media, with some references to methods for protecting against such corrosion. Included are factors contributing to the onset of pitting corrosion. Emphasis is placed on exposure to water, especially in tubing for heat exchangers and water conduits. Many of the citations present studies on exposure to sea water. Some references pertain to the detection of pitting corrosion in installations and the evaluation of the degree of pitting present. (Contains 250 citations and includes a subject term index and title list.)

1993-09-01

349

Anaerobic fermenter-decanter for the purification of residual water from sugar refineries, with recovery of combustible methane  

Energy Technology Data Exchange (ETDEWEB)

An anaerobic fermenter-decanter for the purification of residual water from the sugar industry, with recovery of methane, consists of a tank with inclined walls, with a central agitator on a vertical shaft. A flexible cover anchored by its periphery to the walls of the tank and totally submerged forms a collecting pocket for the fermentation gases. The water to be purified is introduced, after being heated to about 35, towards the bottom of the tank near the agitator. A metal collecting bell with submerged edges and with the shaft of the agitator passing axially through it is connected by its edges to a central opening of the cover. The purification yields may exceed 90%.

1981-10-06

350

Experimental study on the air/water counter-current flow limitation in a model of the hot leg of a pressurized water reactor  

Energy Technology Data Exchange (ETDEWEB)

An experimental investigation on the air/water counter-current two-phase flow in a horizontal rectangular channel connected to an inclined riser has been conducted. This test-section representing a model of the hot leg of a pressurized water reactor is mounted between two separators in a pressurized experimental vessel. The cross-section and length of the horizontal part of the test-section are (0.25 m x 0.05 m) and 2.59 m, respectively, whereas the inclination angle of the riser is 50 deg. The flow was captured by a high-speed camera in the bended region of the hot leg, delivering a detailed view of the stratified interface as well as of dispersed structures like bubbles and droplets. Countercurrent flow limitation (CCFL), or the onset of flooding, was found by analyzing the water levels measured in the separators. The counter-current flow limitation is defined as the maximum air mass flow rate at which the discharged ...

2008-12-15

351

Nonlinear dynamic analysis of high energy line pipe whip  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a nonlinear dynamic analysis of TVA high energy line pipe whip tests using the ABAQUS-EPGEN code. The analysis considers the effects of large deformation and strain rate on resisting moment and energy absorption capability. The numerical results of impact forces, impact velocities, pipe strains, and reaction forces at pipe supports are compared to the TVA test data. The calculated pipe whip impact time and forces are also compared with those predicted using current industry practice. The calculated pipe support reaction forces are found to be in good agreement with the TVA test data except for some peak values at the very beginning of the pipe break. These peaks are believed to be due to stress wave propagation which cannot be addressed by the ABAQUS code. Both elbow crushing and strain rate have been approximately simulated. The effects are ...

1984-02-01

352

Multiple-Purpose Project, Little Blue River Basis East Fork ...  

Science.gov (United States)

... 146 27 1 Aug 83, outlet works excavation. Sewer pipe installation. ... No. 157. Outlet works excavation. Sewer pipe installation. ...

1990-09-01

353

Analytical studies of four-inch pipe whip tests under BWR LOCA conditions  

Energy Technology Data Exchange (ETDEWEB)

The purpose of pipe rupture studies in JAERI is to perform model tests on pipe whip, restraint behavior, jet impingement and jet thrust force, and to establish a computational method for analyzing these phenomena. This report presents the analytical results of 4-inch pipe whip tests under BWR LOCA conditions. Dynamic response analyses were performed using the general-purpose finite element program ADINA. The test pipe was modelled by straight beam elements and the four restraints were modelled by a single truss element. The analytical results were compared with the experimental results. Impact time and maximum total restraint force showed good agreement with experimental results. On the other hand, pipe strain and pipe deflection could not be predicted so well. The reason for this is that the sliding of the restraint during the pipe whip ...

1985-01-01

354

A study on the transient piping vibration of power plant. Secondary piping system of Wolsung 1 unit  

Energy Technology Data Exchange (ETDEWEB)

In order to maintain a safe operation and availability of generating facilities, qualitative and quantitative assessment of piping vibration was performed vibration sources and damages of piping support was identified on the second piping system of Wolsung nuclear power plant unit 1 .Inspected piping supports and structures in both hot and cold condition .Established evaluation procedures of piping vibration .Performed the static analysis of 2 nd piping system .Established optimal vibration reducing method .The measured vibration level after installing rigid supports and energy absorbing type restraint was reduced about 7 times in velocity unit (author). 24 refs., 95 figs.

1996-08-01

355

Surface wettability effect on an indirect evaporative cooling system  

Energy Technology Data Exchange (ETDEWEB)

Indirect evaporative air coolers that use air-to-air plate-type heat exchangers show good promise (compared with compression air-conditioning systems) of extending the energy savings from arid, low-humidity areas to more widespread climatic conditions. However, no systematic experiment had been done concerning the effect of the wettability of aluminum plates on the effectiveness of the indirect evaporative cooling system. In this study, a testing apparatus was built where only one secondary channel and two primary channels were used so that different surfaces could be easily tested to determine the system`s effectiveness and the heat transfer coefficient. The advantage of this experimental apparatus is that plates of the heat exchanger can be easily changed in the test section instead of fabricating a complete heat exchanger for each test. A dynamic contact analyzer was used to quantitatively measure ...

1996-11-01

356

Experimental evaluation of a non-azeotropic working fluid for geothermal heat pump system  

Energy Technology Data Exchange (ETDEWEB)

Geothermal energy resources are found in many countries. A reasonable and efficient utilization of these resources has been a worldwide concern. The application of geothermal heat pump systems (GHPS) can help increase the efficiency of using geothermal energy and reduce the thermal pollution to the earth surface. However, this is only possible with a proper working fluid. In this paper, a non-azeotropic working fluid (R290/R600a/R123) is presented for a GHPS where geothermal water at 40-45{sup o}C and heating network water at 70-80{sup o}C serve as the low and high temperature heat sources. Experimental results show that the coefficient of performance (COP) of a GHPS using the working fluid is above 3.5 with the condensation temperature above 80{sup o}C and the condensation pressure below 18 bar, while the temperature of the geothermal water is reduced from ...

2004-06-01

357

Experimental evaluation of a non-azeotropic working fluid for geothermal heat pump system  

International Nuclear Information System (INIS)

Geothermal energy resources are found in many countries. A reasonable and efficient utilization of these resources has been a worldwide concern. The application of geothermal heat pump systems (GHPS) can help increase the efficiency of using geothermal energy and reduce the thermal pollution to the earth surface. However, this is only possible with a proper working fluid. In this paper, a non-azeotropic working fluid (R290/R600a/R123) is presented for a GHPS where geothermal water at 40-45 deg. C and heating network water at 70-80 deg. C serve as the low and high temperature heat sources. Experimental results show that the coefficient of performance (COP) of a GHPS using the working fluid is above 3.5 with the condensation temperature above 80 deg. C and the condensation pressure below 18 bar, while the temperature of the geothermal water is reduced from 40-46 ...

2004-06-01

358

Conjugate heat transfer of a finned tube. Part B: Heat transfer augmentation and avoidance of heat transfer reversal by longitudinal vortex generators  

Energy Technology Data Exchange (ETDEWEB)

Numerical investigations of three-dimensional flow and heat transfer in a finned tube with punched longitudinal vortex generators (LVG`s) are carried out for Reynolds number of 250 and 300. Air with a Prandtl number of 0.7 is used as the fluid. The flow is both thermally and hydrodynamically developing. The LVG is a delta winglet pair (DWP) punched out of the fin and is located directly behind the tube, symmetrically separated by one tube diameter. The DWP generates longitudinal vortices in the wake of the tube, defers flow separation on the tube, deflects the main stream into the tube wake, and strong reduces the ``dead water zone.`` Heat transfer reversal is avoided by the DWP. Comparison of the span-averaged Nusselt numbers for the fin with and without DWP shows significant local heat transfer enhancement of several hundred percent in the tube wake. For Re = 300 and Fi = 200 the global ...

1995-08-01

359

Processing technology for heat resisting resin suitable for small and high performance products. ; Semiaromatic polyamide applicable to regular injection molding. Kogata-koseinoka wo jitsugensuru tainetsu jushi no kako gijutsu. ; Tsujo no shashutsu seikei ga dekiru han hokozoku poriamido  

Energy Technology Data Exchange (ETDEWEB)

Products having balanced melting point and decomposition temperature have been developed by employing nylon 6T fundamental molecular structure and selected copolymer components, Arlen being one of the products. It has heat resistance as good as that of super-engineering plastics, low water absorption, and excellent cost-performance which can be used for normal injection molding machines. The unit price per kilogram is low when its high heat resistance is taken into consideration. The coefficient of water absorption is as low as about 1/3 of that of nylon 66, and it can be considered to be a low water absorbing amide. The molding temperature is from 320[degree]C to 350[degree]C, the decomposition temperature is 395[degree]C at 2% weight decreasing temperature, and normal injection molding can be employed. It has excellent soldering resistance, high temperature rigidity, dimensional ...

1994-05-01

360

Determination of water level profile along heat exchange tubes of horizontal steam generator PGV 1000 M  

International Nuclear Information System (INIS)

A mathematical model is described for determining the level profile along the length of heat exchange tubes in a horizontal steam generator, and for determining the conditions in the steam cushion under the perforated sheet. The water level area is divided in the model into 36 partial elements; for analysis of the conditions under the level, the steam-water space is divided into four areas. The results of the calculations were compared with measurement results for the steam generator rated values. Very good agreement was found. The results show that, among others, the supply water distribution very much affects the conditions in the area of the steam cushion and of the bubble vacuum. Also, the average steam load of the inner bundle tubes is significantly higher than that of the outer bundles. It was also shown that permanent steam generator operation with exposed top tube rows may occur even in some ...

361

Safety significance of ATR passive safety response attributes  

International Nuclear Information System (INIS)

The Advanced Test Reactor (ATR) at the Idaho National Engineering Laboratory was designed with some passive safety response attributes which contribute to the safety of the facility. The three passive safety attributes being evaluated in the paper are: 1) In-core and in-vessel natural convection cooling, 2) a passive heat sink capability of the ATR primary coolant system (PCS) for the transfer of decay power from the uninsulated piping to the confinement, and 3) gravity feed of emergency coolant makeup. The safety significance of the ATR passive safety response attributes is that the reactor can passively respond to most transients, given a reactor scram, to provide adequate decay power removal and a significant time for operator action should the normal active heat removal systems and their backup systems both fail. The ATR Interim Level 1 Probabilistic Risk Assessment (PRA) models and results were used to evaluate the ...

1990-03-01

362

Examination of scaling criteria for nuclear reactor thermal-hydraulic test facilities  

International Nuclear Information System (INIS)

Scaling criteria for a natural-circulation loop are examined. The present state of knowledge of scaling to obtain similarity during single- and two-phase flow conditions in a closed loop are reviewed, and an alternative development of two-phase similarity parameters is presented. The loop scaling criteria are the results of analyses in which flow from one component to another is considered. In this work, boundary conditions for the closed loop are developed to obtain scaling criteria for leak flow, injection flow, and heat loss to ambient. The leak scaling criteria are specialized for modeling approaches using prototypic fluid at prototypic or reduced pressures. The derived scaling parameters are examined for their application to two existing scaled test facilities: the Multi-Loop Integral System Test (MIST) facility at Babcock and Wilcox, and the UMCP 2 x 4 facility at the University of Maryland College Park. The heat loss similarity analysis ...

1987-01-01

363

Potential for hot-dry-rock geothermal resources: experimental results  

Science.gov (United States)

Hot dry rock (HDR) contains insufficient permeability and fluid for natural hydrothermal development, but water pumped in a circulation loop through a HDR reservoir (hydraulically fractured between two drill holes) is being tested and evaluated. The formation of such in situ heat transfer systems, and subsequent testing of the man-made geothermal reservoirs in the Jemez volcanic field, New Mexico have already indicated the technical feasibility of the hot dry rock (HDR) geothermal concept. Documented production history and heat-extraction data obtained during the period from 1978 to 1980 have confirmed heat transfer, low water loss, and predictable thermal drawdown models for the HDR systems. During a nine month test of closed-loop heat extraction operations, 15 x 10/sup 6/ kWh of thermal energy were produced. The effective heat-transfer ...

1982-01-01

364

Reflux boiling heat removal in a scaled TMI-2 system test facility  

International Nuclear Information System (INIS)

An investigation of decay heat removal by the reflux boiling process was performed on a 1/18 linear-scaled test facility simulating the Three Mile Island (TMI-2) primary system. The objective was to clarify reflux boiling phenomena and core cooling effectiveness. Principal test variables included: core power, primary system water and gas inventories, and steam generator secondary-side coolant flow rate. Of 49 tests conducted, 43 achieved a steady-state heat rejection mode within 3 hours. Subsequent analyses identified two distinct reflux boiling modes. Based upon our current understanding, reflux boiling appears to be an effective process for removing decay heat in a broad range of the conditions investigated for a plant of the TMI configuration.

1980-06-01

365

Process design of the LASL Bismuth Sulfate thermochemical hydrogen cycle  

Science.gov (United States)

A new process engineering flowsheet reflecting an improved design of the LASL Bismuth Sulfate thermochemical cycle is presented. The design is based on laboratory data that indicate a lowered endothermic heat load for a partial decomposition of the solid bismuth sulfate. A small electrical energy demand should result from operation of the sulfur dioxide electrolytic step at lower acid concentration, in principle. The results of the flowsheeting analysis yield a thermal efficiency of 50% for the cycle when coupled to a conceptual fusion energy heat source at 1500/sup 0/K. A parametric analysis shows a slight drop in efficiency as the temperature of the heat source is decreased. The LASL Bismuth Sulfate thermochemical cycle appears to have potential as a means of producing hydrogen from high-temperature heat sources such as fusion, fission, and solar energy; it also appears to be competitive with ...

1979-01-01

366

Natural circulation decay heat removal experiments and analysis in an LMFBR fuel assembly  

International Nuclear Information System (INIS)

Water flow experiments were conducted on natural circulation decay heat removal with an electrically heated 91-rod bundle. Experimental results were compared with analytical predictions to provide thermal hydraulic characteristics for LMFBR Fuel assemblies under a low flow, typical of the natural circulation regime. The results revealed that, at low flow rate region (Re<1,200), axial friction loss in a heated bundle increases with buoyancy effect. The radial temperature profile provides some insight regarding the concept that coolant redistribution would occur. COBRA-V-I predictions are successfully proved validity in comparison with experimental results.

1982-07-01

367

Industrial energy thrift scheme. Energy use in the footwear, leather and fur industries. Report No. 22  

Energy Technology Data Exchange (ETDEWEB)

Visits were made to selected manufacturing units with 25 or more employees. Information was gathered on energy consumption and advice was given on the opportunities available for improving the efficiency of energy use. Potential energy savings are estimated and recommendations are made on the action that should be taken to improve the efficiency of energy use. In the footwear industry space heating controls, improvements in boiler plant and steam services along with building insulation provide most of the savings potential. In the leather industries major energy saving opportunities can be found in low-temperature drying, and heat recovery, where the use of heat pumps could contribute substantial savings in drying and process water heating. Boiler controls and good housekeeping are areas where firms can make worthwhile savings at very little capital cost. (MCW)

1980-11-01

368

Heat and mass transfer analogy studies of binary liquid mixture in comparison with ethanol-n-heptane evaporating to air  

Energy Technology Data Exchange (ETDEWEB)

An experimental and theoretical study of heat and mass transfer analogy and a comparison of that to a binary liquid mixture evaporation is presented. Common organic solvents, ethanol and n-heptane, were used to form an alcohol - hydrocarbon mixture. Studies were carried out in a horizontal rectangular channel having air flow velocities of 0.2 - 0.9 m/s. Heat transfer coefficients were measured with a copper plate resistor and mass transfer coefficients with a square pool. The heat and mass transfer analogy is presented for a system having two evaporating compounds with a fixed value of air flow and verified by measuring and comparing mass transfer coefficients for distilled water with air flow velocities of 0.2 - 0.9 m/s. An illustrative example of the use of the theory for industrial ventilation is presented. (author)

1995-12-31

369

Coupling of geothermal heat pumps with thermal solar collectors  

Energy Technology Data Exchange (ETDEWEB)

The study discussed relates to the design and development of a process consisting of combining a reversible geothermal heat pump with thermal solar collectors for building heating and cooling and the production of domestic hot water. The proposed process, called GEOSOL, has been installed in a 180 m{sup 2} private residence in 2004. This installation is the subject of long-term experimental follow-up to analyse the energy-related behavior of the installation at all times of the year. In addition, different configurations of this combined system (geothermal heat pump and thermal solar collectors) have been defined and will be simulated numerically using TRNSYS software. A comparative analysis of these different alternative versions will be conducted to determine the best configuration(s) of the GEOSOL process in terms of energy, economical and environmental performances. (author)

2007-07-15

370

Continuous method development and numerical study of HHV water gas production by pulverized coal  

British Library Electronic Table of Contents (United Kingdom)

In energy industries, it is always of difficulty to produce high heat value(HHV) gas continuously using pulverized coal. In this paper, a new type furnace for partitioned alternative gasification using pulverized coal is developed, in which the oxidation and reduction reaction occur alternatively with the dropping of pulverized coal and finally HHV gas could be continuously obtained at the reduction zone exit and low heat value(LHV) gas at the oxidation zone exit. Furthermore, the gasification characteristics and their factors in furnace are numerically simulated under two dimensional model with a self-coded program, based on heat, mass and energy transfer as well as reaction principles. It is found that the producing rate of HHV gas is 1.10Nm3/kg with heat value of 11.72MJ/Nm3, however, t...

2011-01-01

371

Nonlinear dynamic analysis of high energy line pipe whip  

International Nuclear Information System (INIS)

To facilitate potential cost savings in pipe whip protection design, TVA conducted a 1'' high pressure line break test to investigate the pipe whip behavior. The test results are available to EPRI as a data base for a generic study on nonlinear dynamic behavior of piping systems and pipe whip phenomena. This paper describes a nonlinear dynamic analysis of the TVA high energy line tests using ABAQUS-EPGEN code. The analysis considers the effects of large deformation and high strain rate on resisting moment and energy absorption capability of the analyzed piping system. The numerical results of impact forces, impact velocities, and reaction forces at pipe supports are compared to the TVA test data. The pipe whip impact time and forces have also been calculated per the current NRC guidelines and compared. The calculated ...

372

Finite element analysis of pipe whip restraint behavior under jet thrust forces  

International Nuclear Information System (INIS)

Many types of pipe whip restraints are installed to protect the structural components from the anticipated pipe whip phenomena of high energy lines in nuclear power plants. It is necessary to investigate these phenomena accurately in order to design the pipe whip restraints properly and/or to evaluate the acceptability of the pipe whip restraint design. Various research programs have been conducted in many countries to develop analytical methods and to verify the validity of the methods. In this study, various types of finite elements in ANSYS, the general purpose finite element computer grogram, was used to simulate the postulated pipe whips to obtain impact loads and the calculted results were compared with the specific experimental results from the sample pipe whip test for the U-chaped pipe whip restraints. Some calculational models, ...

373

Experimental studies of pipe whip and impact: Final report  

Energy Technology Data Exchange (ETDEWEB)

An experimental and computational study was undertaken to estimate the effects of pipe rupture and induced pipe whip impact on surround structures considered either as rigid or deformative such as concrete slabs. This program included sixteen tests using 3 inch schedule 80 (or 10) pipes made of carbon steel similar to A106 grade B. The study consisted of tests on rigid target and on concrete slab. The investigation of whip phase and impact phase was done separately for each test. For pipe impact on rigid targets, the impact forces are found to be directly related to the crush strength of the pipe and the general pipe deformation following the impact. For pipe impact on concrete slabs, the response of the target to the pipe impact needs to take into account the local effect such as penetration and localized damage on the ...

1987-02-01

374

Experimental and analytical studies of 4-inch pipe whip tests under PWR LOCA conditions  

International Nuclear Information System (INIS)

The purposes of the pipe rupture studies at the Japan Atomic Energy Research Institute are to perform the model tests on the pipe whip of a pipe-restraints system, to get jet impingement force and blowdown thrust force, and to establish the computational method for the analysis of these phenomena. This paper presents the experimental and analytical results of the pipe whip tests carried out under the PWR LOCA conditions using the test pipe of 4-inch diameter and the U-shaped restraints. In the tests, the gap between the test pipe and the restraints was set nearly constant and the overhang length was 250 mm, 400 mm or 650 mm. The dynamic strains and residual deformations of the test pipe and restraints, and the restraint force were measured to clarify the effects of the overhang length on the pipe whip behaviors of the ...

375

TRACE code modeling of the horizontal steam generator of the PACTEL facility and calculation of a loss-of-feedwater experiment  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the modeling of horizontal steam generator with the TRACE code and calculation results of a loss-of-feedwater (LOF-10) experiment at the PACTEL facility. Parallel Channel Test Loop (PACTEL) is an integral test facility for a VVER-440 type nuclear reactor. The main objectives were to prepare a simulation model for its horizontal steam generator with the TRACE thermal hydraulic code and assess different modeling options of the code. PACTEL experiment LOF-10 was chosen for this assessment. The calculation results showed that TRACE is capable in simulating horizontal steam generator behavior both in steady state and during loss-of-feedwater transient. The phenomenon of heat transfer from primary to secondary side, steam superheating and flow reversal in the lowest heat exchange tubes were studied in detail. Different nodalization options were introduced. In the simulation of PACTEL loss-of-feedwater experiment LOF-10, the main ...

2010-11-15

376

TRACE code modeling of the horizontal steam generator of the PACTEL facility and calculation of a loss-of-feedwater experiment  

International Nuclear Information System (INIS)

This paper describes the modeling of horizontal steam generator with the TRACE code and calculation results of a loss-of-feedwater (LOF-10) experiment at the PACTEL facility. Parallel Channel Test Loop (PACTEL) is an integral test facility for a VVER-440 type nuclear reactor. The main objectives were to prepare a simulation model for its horizontal steam generator with the TRACE thermal hydraulic code and assess different modeling options of the code. PACTEL experiment LOF-10 was chosen for this assessment. The calculation results showed that TRACE is capable in simulating horizontal steam generator behavior both in steady state and during loss-of-feedwater transient. The phenomenon of heat transfer from primary to secondary side, steam superheating and flow reversal in the lowest heat exchange tubes were studied in detail. Different nodalization options were introduced. In the simulation of PACTEL loss-of-feedwater experiment LOF-10, the main ...

2010-11-01

377

Heat transfer augmentation for high heat flux removal in rib-roughened narrow channels  

International Nuclear Information System (INIS)

Heat transfer augmentation in narrow rectangular channels in a target system is a very important method to remove high heat flux up to 12 MW/m"2 generated at target plates of a high-intensity proton accelerator of 1.5 GeV and 1 mA with a proton beam power of 1.5 MW. In this report, heat transfer coefficients and friction factors in narrow rectangular channels with one-sided rib-roughened surface were evaluated for fully developed flows in the range of the Reynolds number from 6,000 to 1,00,000; the rib pitch-to-height ratios (p/k) were 10,20 and 30; the rib height-to-equivalent diameter ratios (k/De) were 0.025, 0.03 and 0.1 by means of previous existing experimental correlations. The rib-roughened surface augmented heat transfer coefficients approximately 4 times higher than the smooth surface at Re=10,000, p/k=10 and k/De=0.1; friction factors increase around 22 times higher. In this case, higher ...

2001-04-08

378

Heat transfer augmentation for high heat flux removal in rib-roughened narrow channels  

Energy Technology Data Exchange (ETDEWEB)

Heat transfer augmentation in narrow rectangular channels in a target system is a very important method to remove high heat flux up to 12 MW/m{sup 2} generated at target plates of a high-intensity proton accelerator of 1.5 GeV and 1 mA with a proton beam power of 1.5 MW. In this report, heat transfer coefficients and friction factors in narrow rectangular channels with one-sided rib-roughened surface were evaluated for fully developed flows in the range of the Reynolds number from 6,000 to 1,00,000; the rib pitch-to-height ratios (p/k) were 10,20 and 30; the rib height-to-equivalent diameter ratios (k/De) were 0.025, 0.03 and 0.1 by means of previous existing experimental correlations. The rib-roughened surface augmented heat transfer coefficients approximately 4 times higher than the smooth surface at Re=10,000, p/k=10 and k/De=0.1; friction factors increase around 22 times higher. In this case, higher ...

1997-03-01

379

Restoration of a forested wetland ecosystem in a thermally impacted stream corridor  

Energy Technology Data Exchange (ETDEWEB)

The Savannah River Swamp is a 3,020 Ha forested wetland on the floodplain of the Savannah River and is located on the Department of Energy`s Savannah River Site (SRS). Major impacts to the swamp hydrology occurred with the completion of the production reactors and one coal-fired powerhouse at the SRS in the early 1950`s. Water was pumped from the Savannah River, through secondary heat exchangers of the reactors, and discharged into three of the tributary streams that flow into the swamp. This continued from 1954 to 1988 at various levels. The sustained increases in water volume resulted in overflow of the original stream banks and the creation of additional floodplains. Accompanying this was considerable erosion of the original stream corridor and deposition of a deep silt layer on the newly formed delta. Heated water was discharged directly into Pen Branch and ...

1995-09-01

380

Prediction of thermal conductivity of ethylene glycol-water solutions by using artificial neural networks  

Energy Technology Data Exchange (ETDEWEB)

The objective of this study is to develop an artificial neural network (ANN) model to predict the thermal conductivity of ethylene glycol-water solutions based on experimentally measured variables. The thermal conductivity of solutions at different concentrations and various temperatures was measured using the cylindrical cell method that physical properties of the solution are being determined fills the annular space between two concentric cylinders. During the experiment, heat flows in the radial direction outwards through the test liquid filled in the annual gap to cooling water. In the steady state, conduction inside the cell was described by the Fourier equation in cylindrical coordinates, with boundary conditions corresponding to heat transfer between the solution and cooling water. The performance of ANN was evaluated by a regression analysis between the predicted and the ...

2009-10-15

381

Non-standard natural circulation in primary circuit of VVR-440, behavior of horizontal steam generator in this regime  

Energy Technology Data Exchange (ETDEWEB)

Analyzing various SBLOCA with high pressure safety injection (HPSI) at VVER-440/213, we met a surprising phenomenon - a 'natural' circulation post SG heat transfer reversal. This is not usual, because normal natural circulation (NC) in primary circuit is connected with positive heat transfer at SG. If there is reverse heat transfer at SG (as soon as the break enthalpy outflow is sufficient for removal of reactor decay heat), it should obstruct any natural circulation. The question was, what is the driving force of this 'non-standard natural circulation'. After all we revealed that force - it is the density difference between the colder water in reactor downcomer (cold water from HPSI) and warmer water in inner reactor (lower plenum, core, upper plenum). This phenomenon could be confusing for operating ...

2001-07-01

382

Non-standard natural circulation in primary circuit of VVR-440, behavior of horizontal steam generator in this regime  

International Nuclear Information System (INIS)

Analyzing various SBLOCA with high pressure safety injection (HPSI) at VVER-440/213, we met a surprising phenomenon - a 'natural' circulation post SG heat transfer reversal. This is not usual, because normal natural circulation (NC) in primary circuit is connected with positive heat transfer at SG. If there is reverse heat transfer at SG (as soon as the break enthalpy outflow is sufficient for removal of reactor decay heat), it should obstruct any natural circulation. The question was, what is the driving force of this 'non-standard natural circulation'. After all we revealed that force - it is the density difference between the colder water in reactor downcomer (cold water from HPSI) and warmer water in inner reactor (lower plenum, core, upper plenum). This phenomenon could be confusing for operating personal, because there would be an ...

2001-03-20

383

Finalisation of design provision for active process water system shut down at TAPP-3 and 4  

International Nuclear Information System (INIS)

Active Process Water (APW) system is provided as a unitized system in TAPP-3 and 4. Maintenance on APW system requires shutdown of this system. As shut down heat exchangers are fed by APW system; during APW system shutdown cold shutdown state cannot be maintained. Therefore safety analysis is done to optimize the duration of reactor shutdown (which means low decay heat) after which APW shutdown can be taken with minimum water supply to the shutdown heat exchangers. Based on this analysis, it is proposed in technical specification that APW system shutdown can be taken after 7 days of reactor shutdown with shutdown heat exchangers supplied with about 20 % of normal APW flow. With this configuration, PHTS, moderator, end shield, calandria vault water temperature can be maintained within limits. A design provision is made at TAPP-3 and 4 to ...

2006-11-13

384

The possibility for formation of macro-cell corrosion in a liquid with low electrical conductivity  

International Nuclear Information System (INIS)

The possibility of electrochemical corrosion of carbon steel at the rate of 3.25 x 10"-"5 A/cm"2 in water was examined under the conditions present during an accidental pipe rupture at the Mihama nuclear power plant: liquid conductivity, 7.5 #mu#S/cm; dissolved oxygen concentration, 5 ppb or less; pH 8.6#propor to#9.3; ferrous ion concentration, 20 ppb or less; temperature, 142 C. The corrosion rate of iron in a micro-cell with a dissolved oxygen reduction cathode was estimated to be only 1/400 of the preceding rate. On the other hand, that in a micro-cell with a hydrogen ion reduction cathode was estimated to be as high as 1/10 of the preceding rate, that is, 3.25 x 10"-"6 A/cm"2. Two important factors may have influenced the corrosion rate: the remarkable wall thinning, which must have been the direct cause of the rupture of the pipe, was located close to, and downstream from, an orifice; and, the ...

2011-05-01

385

Two Dimensional CFD Analyses on the Heat Transfer for a Supercritical Pressure CO_2  

International Nuclear Information System (INIS)

The Supercritical Water Cooled Reactor(SCWR) operates in a pressure around 25MPa and temperature of 293#approx#510 .deg. C. In order to study the heat transfer behaviors and good comparisons between the various fluids, a heat transfer test loop(SPHINX) using CO_2 has been constructed in KAERI as a part of international research program, I-NERI. At a supercritical pressure, the heat transfer coefficient is much larger than that estimated from the Dittus-Boelter correlation for a relatively large flow rate with moderate wall heat flux conditions. This phenomenon was explained by the rapid variations of the physical properties near the wall with the temperature. On the contrary, the heat transfer becomes worse when the bulk fluid enthalpy is below the pseudo-critical enthalpy under a low flow rate with large heat flux conditions. This ...

2005-10-27

386

On the anatomy of the adsorption heat versus loading as a function of temperature and adsorbate for a graphitic surface.  

Science.gov (United States)

In this paper we review and classify the various patterns of isosteric heat versus loading for adsorption of gases on graphitised thermal carbon black at temperatures ranging from below the 3D triple point to temperatures above it, but less than the 3D critical point. We have identified the features of heat curve and highlighted the microscopic origin of these features. The patterns vary with temperature and with the relative strength of the fluid-fluid interaction and solid-fluid interaction. For simple adsorptives (by simple we meant there is no strong association between fluid particles), the heat curve is typified by fluid-fluid attraction and layering phenomena. For adsorptives showing strong association such as water, ammonia and methanol, the heat curve essentially begins below the condensation heat and then approaches it as loading is increased. This is ...

2008-05-24

387

Heat transfer performance of a fin with two fences and tube heat exchanger. Study in the low Reynolds number range; Fence wo fusetsushita fin tsuki kan netsu kokanki unit no ryudo dennetsu sogo tokusei. Tei Reynolds suiki ni okeru kosatsu  

Energy Technology Data Exchange (ETDEWEB)

A three-dimensional steady numerical computation was made for a component model of fin and tube type of compact heat exchangers situated in a uniform flow. In this study, in order to find a clue to design high-efficient heat exchangers, numerical computation was made in the case where two fences are attached on the plate fin surface and their geometrical effects such as their locations, their heights and their attack angles on flow and heat transfer characteristics were investigated especially in the low Reynolds number range. The effect of a hole, open in the plate fin behind the fence, on heat transfer and flow structures was also examined. This hole simulates the hole of the plate fin to be produced in practical application, when a fence is produced by punching from the original plain fin plate. Two fences with holes were found to show several important effects on flow and heat ...

2000-07-25

388

Influence of suspended solids on pitting corrosion of carbon steel in cooling water. Tansoko no koshoku ni oyobosu reikyaku suichu no kendaku busshitsu no eikyo  

Energy Technology Data Exchange (ETDEWEB)

A large amount of industrial water is used for cooling the various process fluids in the petroleum purification factories as well as petroleum chemistry factories. Consequently, a lot of heat exchangers as the necessary constitutional instruments are made of carbon steel. Due to the most of the corrosions of the carbon steel occurring in such cooling water systems are pitting corrosions, the inhibition thereof is extremely important for the elongation of the life of the plants and the stable operation. In this paper, the influences of water quality fractions on pitting corrosion of carbon steel in cooling water circumstance are examined aiming at the fouling in the cooling water. The fouling in the cooling water does not only increase the amount of occurrence of pitting corrosion but also accelerates the progress of pitting corrosion ...

1993-08-15

389

Use of explosive quick depressurization valves in the SBWR project. Dynamic loads induced by their operation  

International Nuclear Information System (INIS)

In General Electric's design of the Simplified Boiling Water Reactor (SBWR), The depressurization valves (DPV) are installed in the reactor pressure boundary: four are connected to the reactor vessel by means of nozzles, and two more are located on the main steam pipes (one DPV for each line), which act during particular transients and/or loss of coolant accidents (LOCA), consequently providing the reactor vessel with a safe quick depressurization system. Once the vessel is de pressurised, the passive gravity-driven cooling system (GDCS) starts to operate, permitting the injection of water required for continuous core cooling. DPVs are leak tight, with welded flaps, actuated by a [striker[hammer***] which is activated by an explosive mixture. The dynamic loads that open these valves include, in addition to those produced by steam (typical in any thermodynamic transient with open/close valves), other important loads that are ...

390

Experimental study on two-phase flow regime transition from stratified to slug flow in a large-height horizontal duct  

Energy Technology Data Exchange (ETDEWEB)

The prediction of two-phase flow regime in the horizontal pipings during a loss-of-coolant accident (LOCA) is important for safety analysis of a pressurized water reactor (PWR). The flow regime transition conditions for a horizontal two-phase air-water flow were studied using a large-height, horizontal rectangular duct test section. The duct dimensions were 700 mm in height, 100 mm in width and 28.3 m in length. The experimental criterion for the flow regime transition from the stratified to slug flow regimes, in terms of the local void fraction and the non-dimensional gas-liquid relative velocity, agreed qualitatively with the prediction by the Mishima-Ishii model that is based on an idea that the interfacial waves with the largest growth rate will develop into a slug. However, the transition in the experiment occurred at systematically lower (by about 40 %) relative velocities than the prediction by the Mishima-Ishii ...

1992-02-01

391

Dynamic modeling of interfacial structures via interfacial area transport equation  

International Nuclear Information System (INIS)

The interfacial area transport equation dynamically models the two-phase flow regime transitions and predicts continuous change of the interfacial area concentration along the flow field. Hence, when employed in the numerical thermal-hydraulic system analysis codes, it eliminates artificial bifurcations stemming from the use of the static flow regime transition criteria. Accounting for the substantial differences in the transport phenomena of various sizes of bubbles, the two-group interfacial area transport equations have been developed. The group 1 equation describes the transport of small-dispersed bubbles that are either distorted or spherical in shapes, and the group 2 equation describes the transport of large cap, slug or churn-turbulent bubbles. The source and sink terms in the right-hand-side of the transport equations have been established by mechanistically modeling the creation and destruction of bubbles due to major bubble interaction mechanisms. In the present paper, the ...

2005-01-01

392

Determination of parameters of the environment for equipment qualification at the Dukovany NPP. Post-accident parameters on the +14.7 m floor. Operating parameters on the +14.7 m floor and in the hermetic zone. Rev. 4  

International Nuclear Information System (INIS)

A detailed outline of the application of the MELCOR and RELAP5/MOD3.1 codes to the analysis of the thermohydraulic response and determination of other parameters of the medium on the floor is given for several classes of secondary coolant circuit accidents along with the description of the related facilities. An overview is presented of the maximum values and time behavior of the thermohydraulic parameters, pressure, temperature, relative humidity, and water level on the floor. Transverse rupture of the steam generator, main steam header, or main feedwater header piping during normal operation is considered as the initiating event. Pressure is only 10% higher than the atmospheric pressure. Air temperature attains a value as high as 100 degC. Relative humidity is 100%, persisting as long as the steam source is available. The water level is typically about 8 cm and never exceeds 15 cm. (M.D.). 16 tabs., 37 figs., 32 refs.

393

Behaviour of OFHC copper in highly pure water; Comportamento del rame OFHC in acqua di elevata purezza  

Energy Technology Data Exchange (ETDEWEB)

In order to gain a wider knowledge of corrosion phenomena in OFHC (oxygen free high conductivity) copper pipes of the stator cooling circuit of a power plant turboalternator, a research program was laid out which is based on the use of an experimental loop simulating real operating conditions as closely as possible. The samples examined were either copper foils or hollow conductors of the type that is normally used in the stator cooling system, and the circulating fluid was high purity water with controlled O/sub 2/, H/sub 2/ and C0/sub 2/ contents. Investigations were focused on the kinetics of O/sub 2/ removal through catalytic resins covered with metallic palladium (at different temperatures and pressures) and on the kinetics of CO/sub 2/ removal through mixed bed resins. Subsequently, attention was directed to the corrosion of copper (in the form of foils or hollow conductors) under different experimental conditions simulating either ...

1991-12-31

396

Experimental studies of 6-inch pipe whip tests under BWR LOCA conditions  

International Nuclear Information System (INIS)

Series of pipe rupture tests have been performed at the Japan Atomic Energy Research Institute to demonstrate the safety of the primary coolant circuits in the event of pipe rupture in nuclear power plants. The pipe whip tests have been conducted to study the dynamic response of the pipe and restraints. The results of the pipe whip tests using test pipes of 4-inch in diameter under the BWR LOCA conditions (285"0C, 6.8 MPa) were reported in the previous paper F8/5 of the 6th SMiRT. The present paper describes the results of the pipe whip tests using test pipes of 6-inch in diameter. The test pipe was made of Type 304 stainless steel and was 165.2 mm in outer diameter and 11.0 mm in thickness, and was fixed at the pipe support so that the length of the test section was 3000 mm. The ...

399

In situ heat transfer in man-made geothermal energy reservoirs  

Energy Technology Data Exchange (ETDEWEB)

Two hot dry rock geothermal energy reservoirs were created by hydraulic fracturing of Precambrian granitic rock on the west flank of the Valles Caldera, a dormant volcanic complex, in the Jemez Mountains of northern New Mexico. Heat was extracted in a closed-loop mode of operation, injecting water into one well and extracting the heated water from a separate production well. The first reservoir was produced by fracturing the injection well at a depth of 2.75 km (9020 ft) where the indigenous rock temperature was 185/sup 0/C. The relatively rapid thermal drawdown of the water produced from the first reservoir, 100/sup 0/C in 74 days, indicated that its effective fracture radius was about 60 m (200 ft). Average thermal power extracted was 4 MW. A second, larger reservoir was created by refracturing the injection well 180 m (600 ft) deeper. Downhole measurements of the ...

1980-01-01

400

Thermogravimetric and specific heat determinations of a commercial reconcentrated sample of ulexite, between room temperature and 1,000 degree centigree; Determinaciones termogravimetricas y de calor especifico de un concentrado comercial de ulexita, entre temperature ambiente y 1.000 grados centigrados  

Energy Technology Data Exchange (ETDEWEB)

The important amount of hydration water in the ulexite (NaCaN{sub 5}O{sub 9}.8H{sub 2}O), allows using calcination methods to increase its B{sub 2}O{sub 3} content. This paper analyses the thermal decomposition reaction of a preconcentrated ulexite through weight loss measurements, which occur during the heating of samples until 1000 degree centigree, Determinations of heat content at each temperature were made using an isoperibol calorimeter. The mean specific heat was calculated from these values, and its dependence on temperature was determined. The maximum weight loss was about 32.5% and the specific heat obtained was 1,13 kJ/kg 0 C for solid samples and 1,38 kJ/kg''0 C for fluid samples. The results are useful for the design of the industrial process, in order to determine the thermal requirements for heating calcined ulexite, and to ...

2006-07-01

401

Basic models and verification study on fuel rod heat-up and fission product release analysis modules in SAMPSON for the IMPACT project  

International Nuclear Information System (INIS)

The super simulator 'SAMPSON' has been developed to show that there exist certain safety margins for light water reactors under hypothetical severe accidents and to investigate realistic measures of accident management by simulating accidents with a parallel computer. Heat-up of fuel rods and release of fission products from fuels are important factors to evaluate source terms. Models for fuel rod heat-up, hydrogen production due to cladding oxidation and cladding deformation and failure in the core region have been developed in the fuel rod heat-up analysis module. Fuel temperatures were calculated by solving the heat conduction equation. The calculated results for fuel temperature and hydrogen production were compared with CORA-13 experiment results. The comparisons showed prediction capability for the heat-up of fuel rods. The fission product release analysis ...

1999-04-19

402

Application of a finite element method to leak before break (LBB) of a heat exchanger  

International Nuclear Information System (INIS)

The leak before break (LBB) concept is difficult to apply to a structure with a thin tube that is immersed in a water environment. A heat exchanger in a nuclear power plant is such a structure. The present paper addresses an application of the LBB concept to a heat exchanger in a nuclear power plant. The minimum leaked coolant amount containing the radioactive material which can activate the radiation detector device installed near the heat exchanger is assumed. The postulated initial flaw size that cannot grow to the critical flaw size within the time period to activate the radiation detector is justified. In this case, the radiation detector can activate the warning signal caused by coolant leakage from initially postulated flaws of the heat exchanger. The nuclear plant can safely shutdown when this occurs. Since the postulated initial flaw size can not grow to the critical flaw ...

2003-08-17

403

An effective convectivity model for simulation of in-vessel core melt progression in a boiling water reactor  

Energy Technology Data Exchange (ETDEWEB)

The present paper is concerned with development and application of a so-called Effective Convection Model (ECM), which aims to provide a detailed, mechanistic description of heat transfer processes in a BWR lower plenum. The ECM is a Computational Fluid Dynamics (CFD)-like tool which employs a simpler and more effective approach to compute heat transfer by solving only energy conservation equation instead of solving the full set of Navier-Stokes and energy equations by a CFD code. We implement the ECM in a CFD code (Fluent), with detailed description of the ECM development, implementation and validation. A dual approach is used to validate the ECM, namely validation against experimental data and against heat transfer results obtained by CFD predictions in the same geometries and conditions. Insights gained from CFD simulations are also used to improve ECM. The ECM capability as an effective tool to simulate ...

2007-07-01

404

An effective convectivity model for simulation of in-vessel core melt progression in a boiling water reactor  

International Nuclear Information System (INIS)

The present paper is concerned with development and application of a so-called Effective Convection Model (ECM), which aims to provide a detailed, mechanistic description of heat transfer processes in a BWR lower plenum. The ECM is a Computational Fluid Dynamics (CFD)-like tool which employs a simpler and more effective approach to compute heat transfer by solving only energy conservation equation instead of solving the full set of Navier-Stokes and energy equations by a CFD code. We implement the ECM in a CFD code (Fluent), with detailed description of the ECM development, implementation and validation. A dual approach is used to validate the ECM, namely validation against experimental data and against heat transfer results obtained by CFD predictions in the same geometries and conditions. Insights gained from CFD simulations are also used to improve ECM. The ECM capability as an effective tool to simulate ...

2007-05-13

405

Numerical investigation of the impact of gas and cooling flow configurations on current and water distributions in a polymer membrane fuel cell through a pseudo-two-dimensional diphasic model  

British Library Electronic Table of Contents (United Kingdom)

For optimal performances, proton exchange membrane fuel cells require fine water and thermal management. Accurate modelling of the physical phenomena occurring in the fuel cell is a key issue to improve fuel cell technology. Here, an analytic steady state diphasic 2D model of heat and mass transfer is presented. Through this model, the aim of this work is to study the influence of local events on the global performances of a fuel cell. A part of the complete model is a microscopic representation of the coupling between water transport and charge transfers in the electrodes. The thickness of the liquid layer around the reactive agglomerates is deduced from the saturation. The evolution of the quantity of water within the catalyst layer is monitored and its influence on the global performanc...

2010-01-01

406

Model for simulation of freezing and thawing processes in building materials  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a mathematical model for simultaneous heat and moisture transfer under freezing-thawing in porous hygroscopic material. Even below O{sup o}C, unfrozen liquid water exists in the material which plays an important role in the processes. The model takes into account the existence of unfrozen liquid water. The system is treated as a three-(gas, liquid and solid) phase system of water. Moisture chemical potential is used as a moisture potential. Under freezing, moisture chemical potential is a unique function of local temperature. So, during freezing, two unknown variables to be solved are solid water content and moisture potential or temperature. A simple example of simulation for freezing processes is shown. (author)

2001-07-01

407

Exergy analysis of the solar multi-effect humidification?dehumidification desalination process  

British Library Electronic Table of Contents (United Kingdom)

An exergy analysis method is presented of the solar multi-effect humidification?dehumidification desalination (HDD) process. Pinch technology is used in the humidification process to determine the maximum possible saturated air temperature and the temperature of water rejected from the unit, and then the dehumidification process to determine the temperature of water leaving from the heat exchanger. The formulae to calculate the exergy of water and saturated air are given. The solar plane collector is used. From exergy analysis, the solar collector has the lowest exergy efficiency; the HDD process has a lower exergy efficiency, and the water rejected has also a large exergy loss. The energy and exergy recovery rate of the desalination process is also lower. The solar multi-effect HDD proces...

2007-01-01

408

Pipework design and operation  

Energy Technology Data Exchange (ETDEWEB)

This book presents the proceedings of a conference dedicated to the design and operation of pipework in all its aspects, involving both metallic and non-metallic materials. Topics considered include a study of single mitre pipe bends using the finite element method; tests to failure of GRP pipe bends under in-plane flexural loading; finite element stress analysis of an equal diameter branch pipe intersection subjected to internal pressure and in-plane moment loadings; finite element stress analysis of extruded outlet tee junctions; design of pipework on the British PWR; a review of advanced remanent life methods for pipes operating in the creep range; pipe whip analysis and design; damping values for piping systems; pipework snubbers based on electro-rheological fluids; and the seismic design of piping systems in the flexible range.

1985-01-01

409

Experimental and analytical studies of pipe whip tests under PWR LOCA conditions  

Energy Technology Data Exchange (ETDEWEB)

A series of pipe rupture tests has been performed at JAERI to demonstrate the safety of primary coolant circuits in the event of pipe rupture in nuclear power plants. Pipe whip tests and jet discharge tests have been conducted under BWR and PWR loss-of-coolant accident (LOCA) conditions. The present paper describes the experimental and analytical results of the pipe whip tests performed under PWR LOCA conditions using 4, 6 and 8-inch test pipes. The tests were carried out at an initial pressure and temperature of 15.7 MPa and 325/sup 0/C, respectively. Moreover, a dynamic analysis of pipe whip tests was carried out using the general purpose finite element programm ADINA.

1987-09-01

410

Evaluation of pipe whip impacts on neighboring piping and walls of the Ignalina nuclear power plant.  

Energy Technology Data Exchange (ETDEWEB)

Presented in this paper is the transient analysis of a Group Distribution Header (GDH) following a guillotine break at the end of the header. The GDH is the most important component of reactor safety in case of accidents. Emergency Core Cooling System (ECCS) piping is connected to the GDH piping such that, during an accident, coolant passes from the GDH into the ECCS. The GDH that is propelled into motion after a guillotine break can impact neighboring GDH pipes or the nearest wall of the compartment. Therefore, two cases are investigated: GDH impact on an adjacent GDH and its attached piping; and GDH impact on an adjacent reinforced concrete wall. A whipping RBMK-1500 GDH along with neighboring concrete walls and pipelines is modeled using finite elements. The finite element code NEPTUNE used in this study enables a dynamic pipe whip structural analysis that accommodates large ...

2002-02-26

411

Comparative study of computational model for pipe whip analysis  

International Nuclear Information System (INIS)

Many types of pipe whip restraints are installed to protect the structural components from the anticipated pipe whip phenomena of high energy lines in nuclear power plants. It is necessary to investigate these phenomena accurately in order to evaluate the acceptability of the pipe whip restraint design. Various research programs have been conducted in many countries to develop analytical methods and to verify the validity of the methods. In this study, various calculational models in ANSYS code and in ADLPIPE code, the general purpose finite element computer programs, were used to simulate the postulated pipe whips to obtain impact loads and the calculated results were compared with the specific experimental results from the sample pipe whip test for the U-shaped pipe whip restraints. Some calculational models, having the spring element between the ...

1993-08-15

412

Study of the state of design for pipe whip. Final report. [PWR; BWR  

Energy Technology Data Exchange (ETDEWEB)

Design methods and parameters are described which are addressed when considering consequences of a postulated pipe rupture event in a nuclear plant design. Parameters discussed are break opening time and size, resultant blowdown characteristics of the effluent from the broken pipe, jet reaction and impingement loading, pipe motion, and pipe impact loading on steel and concrete structures. The impact the various parameters have on overall plant designs and conservatisms inherent in each consideration are evaluated in a qualitative nature. Finally, recommendations are provided for each parameter discussed for further evaluation and study.

1980-01-01

413

Survey of UEC estimates for space heating, DHW heating, and appliances energy usage  

Energy Technology Data Exchange (ETDEWEB)

Natural Resources Canada commissioned an informal survey in which 18 organizations, mainly utilities from across Canada were contacted by letter or fax to gather data regarding unit energy consumption (UEC) of space heating, domestic hot water (DHW) heating and appliances. The data was used in updating and refining the residential energy end-use model used at NRCan. The survey included energy load, UEC, efficiency, and per cent saturation for both space heating and water heating equipment for all fuel types including electric, natural gas, oil, wood and propane used in single detached, single attached, apartment and mobile homes. A list of UEC and per cent saturation for major appliances such as refrigerators, freezers, clothes washers and dryers, cooktop/ovens, central air-conditioners, and lighting is also included in the survey. The collected data was ...

1998-03-01

414

Two-fluid modeling of condensation in the presence of noncondensables in two-phase channel flows  

Energy Technology Data Exchange (ETDEWEB)

Condensing two-phase channel flow occurs in many industrial applications, including heating and refrigeration systems. It can also occur in certain nuclear reactor accidents. For example, during a small-break loss-of-coolant accident in a pressurized water reactor, following the partial depletion of the primary coolant, condensation of steam on the primary side of the steam generator tubes can provide a heat sink for disposal of the decay heat generated in the reactor core. Condensing two-phase flow can also play an important role in the operation of the passive emergency cooling system in the advanced simplified boiling water reactor. Here, steady-state condensation in the presence of a noncondensable in a concurrent two-phase channel flow is analyzed using a two-fluid model. The effect of noncondensables on the combined heat transfer at the liquid-gas mixture ...

1995-01-01

415

Thermal stress cracking and the enhancement of heat extraction from fractured geothermal reservoirs  

Science.gov (United States)

Given sufficient time, the extraction of heat from geothermal reservoirs formed by the hydraulic fracturing of competent rock will eventually result in the formation of thermal stress cracks in the reservoir. These cracks penetrate the rock in a manner such that the penetration-to-spacing ratio is approximately one. The penetration depends upon the extent of cooling and the square root of time. Initially then, the cracks are closely spaced and penetrate but little, so that a crazing pattern is apparent; but with increasing time some of these cracks, now more widely spaced, grow deeper. Eventually these larger cracks attain a critical aperture such that significant rates of water flow can be established within them and thus the newly created heat transfer area becomes useful for heat extraction. At the same time that cracks are forming within the main reservoir, thermal cracking also occurs in the ...

1978-04-01

416

Potential for geothermal development in Southern Poland  

Energy Technology Data Exchange (ETDEWEB)

This paper discusses the potential for geothermal energy use in the central part of Southern Poland, such as the availability of thermal aquifers and the techniques for putting the latter to practical use. The geological and geothermal features of the region are presented within the context of the existence of aquifers containing geothermal resources that could be used in space heating. Also discussed are the three main geological units where thermal waters are known to exist: the Carpathians, the Miechow Trough, and the Silesian-Cracow Monocline. Particularly favourable hydrogeological conditions exist in the Inner Carpathians, in the Podhale Trough, where there is already one geothermal company using geothermal energy, Geotermia Podhalanska S.A. Equally interesting from the geothermal point of view are the areas north of the Cracow-Tarnow line, where, in Mesozoic aquifers, water temperatures range from 20 to 60 {sup o}C. ...

2004-06-01

417

Heavy water reactor facility large-scale containment cooling test program  

Science.gov (United States)

The Heavy Water Reactor Facility (HWRF), as part of the defense-in-depth philosophy to mitigate the effect of design-basis and severe accidents, is equipped with a passive containment cooling system (PCCS). The function of the PCCS is to provide a safety-grade path to the ultimate heat sink for the removal of the reactor coolant system sensible heat and core decay heat. Ambient air enters an annular space between the steel containment shell and the surrounding concrete shield building through inlets in the shield building wall, is heated via natural convection, rises, and exits the building through a chimney located above the containment dome. A test program is in place to access parameters important to the effective operation of the PCCS. This paper focuses on the large-scale tests (LSTs). The objectives of these tests are as follows: (1) demonstrate natural circulation cooling ...

1992-01-01

418

Heavy water reactor facility large-scale containment cooling test program  

International Nuclear Information System (INIS)

The Heavy Water Reactor Facility (HWRF), as part of the defense-in-depth philosophy to mitigate the effect of design-basis and severe accidents, is equipped with a passive containment cooling system (PCCS). The function of the PCCS is to provide a safety-grade path to the ultimate heat sink for the removal of the reactor coolant system sensible heat and core decay heat. Ambient air enters an annular space between the steel containment shell and the surrounding concrete shield building through inlets in the shield building wall, is heated via natural convection, rises, and exits the building through a chimney located above the containment dome. A test program is in place to access parameters important to the effective operation of the PCCS. This paper focuses on the large-scale tests (LSTs). The objectives of these tests are as follows: (1) demonstrate natural circulation cooling ...

1992-11-15

419

Research on pipe whip and jet under LOCA conditions, (2)  

International Nuclear Information System (INIS)

The paper describes the experimental and analytical results of the pipe whip tests performed under the PWR LOCA conditions using 4, 6 and 8 inch test pipes. The tests were carried out at an initial pressure and a temperature of 15.7 MPa and 325 "0C. Two different types of tests were performed. One was the cantilever type pipe whip test using the test pipe of 3000 mm in length and U-shaped restraints. The other was the cross-over leg pipe whip test using a 1/6 model of piping in the PWR nuclear power plants. The cantilever type pipe whip tests were performed to investigate the influences of overhang length and pipe diameter on the pipe whip behavior. The movement of the test pipe is limited effectively by the restraints when the overhang length is short. The restraint force ...

420

IMPROVED NATURAL GAS STORAGE WELL REMEDIATION  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the research conducted during Budget Period One on the project ''Improved Natural Gas Storage Well Remediation''. The project team consisted of Furness-Newburge, Inc., the technology developer; TechSavants, Inc., the technology validator; and Nicor Technologies, Inc., the technology user. The overall objectives for the project were: (1) To develop, fabricate and test prototype laboratory devices using sonication and underwater plasma to remove scale from natural gas storage well piping and perforations; (2) To modify the laboratory devices into units capable of being used downhole; (3) To test the capability of the downhole units to remove scale in an observation well at a natural gas storage field; (4) To modify (if necessary) and field harden the units and then test the units in two pressurized injection/withdrawal gas storage wells; and (5) To prepare the project's final report. This report ...

2001-12-01

421

Two-phase Flow Regime Maps in Horizontal and Vertical Tubes  

Energy Technology Data Exchange (ETDEWEB)

A safety analysis code to design a pressurized water reactor and to obtain the licenses including entire proprietary rights is under development in domestic R and D project. The tasks of KAERI is to develop the constitutive relations including models for defining flow regimes and flow regime related models for inter-phase friction, wall frictions, wall heat transfer, and interphase heat and mass transfer in the two-phase three-field equations. In this paper, the process will be presented for choosing the best flow regime maps which occur in gas-liquid two-phase flow in horizontal and vertical tubes.

2007-10-15

422

Two-phase Flow Regime Maps in Horizontal and Vertical Tubes  

International Nuclear Information System (INIS)

A safety analysis code to design a pressurized water reactor and to obtain the licenses including entire proprietary rights is under development in domestic R and D project. The tasks of KAERI is to develop the constitutive relations including models for defining flow regimes and flow regime related models for inter-phase friction, wall frictions, wall heat transfer, and interphase heat and mass transfer in the two-phase three-field equations. In this paper, the process will be presented for choosing the best flow regime maps which occur in gas-liquid two-phase flow in horizontal and vertical tubes.

2007-10-01

423

Overview of US LMFBR Structural Materials Mechanical Properties Program  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the objective, scope, and status of the US Department of Energy's Materials and Structures Program to develop a data base on mechanical properties of structural materials for out-of-core structures and components for LMFBRs. Information on the development of a reference data base on materials for the reactor system, reactor enclosure system, primary heat transport system, intermediate heat transport system, and steam generator system is included. In addition, the development of the data and analyses to account for the effects of temperature and stress, as well as water/steam, sodium, and radiation environments, is described. Plans for the development of alternative materials for future out-of-core applications are presented.

1983-01-01

424

Overview of U.S. LMFBR structural materials mechanical properties program  

International Nuclear Information System (INIS)

This paper presents the objective, scope, and status of the U.S. Department of Energy's Materials and Structures Program to develop a data base on mechanical properties of structural materials for out-of-core structures and components for LMFBRs. Information on the development of a reference data base on materials for the reactor system, reactor enclosure system, primary heat transport system, intermediate heat transport system, and steam generator system is included. In addition, the development of the data and analyses to account for the effects of temperature and stress, as well as water/steam, sodium, and radiation environments, is described. Plans for the development of alternative materials for future out-of-core applications are presented. (author).

1983-10-10

425

Improvement of FLOWER code and its application in Daya Bay  

International Nuclear Information System (INIS)

FLOWER, a computer code recommended by USNRC for assessing the environmental impact in tidal regions, was adapted and improved so as to be suitable to deal with the influence of drift stream along seashore to the dilution of contaminants and heat in the bay mouth. And the code outputs were presented with more mid-results such as average concentrations and temperature values for all tides considered. Finally, the modified code is applied to the dispersion calculation of heat and liquid effluents from Daya Bay Nuclear Power Plant, and the impacts from routine operation of the plant on Daya Bay sea waters were given.

426

Heat recovery in polyester production: a case study  

Energy Technology Data Exchange (ETDEWEB)

Energy savings in the synthetic fiber industry could be realized by using autoclave reactor condensate and boiler flue gas heat recovery. The non-cellulose (polyester) production process analysis shows that condensate returning from the reactor to the steam boiler raises inlet temperature, giving a reduced fuel requirement of about 8%. Also, boiler flue gas with a sufficiently high outlet temperature for boiler feed water and combustion air preheating results in further fuel savings. The process with an economizer saves up to 8.44%, and with a combustion air preheater, 6.25%. (Author)

1997-07-01

427

Geothermal resource assessment of the New England states  

Energy Technology Data Exchange (ETDEWEB)

With the exception of Sand Springs in Williamstown, Massachusetts, there are no identifiable hydrothermal geothermal resources in the New England region. The radioactive plutons of the White Mountains of New Hampshire do not, apparently, contain sufficient stored heat to make them a feasible target for an induced hydrothermal system such as exists at Fenton Hill near Los Alamos, New Mexico. The only potential source of low grade heat is the large volume of ground water contained within the unconsolidated sediments related to the Pleistocene glaciation of the region. During the course of the survey an unusual and unexplained thermal anomaly was discovered in St. Johnsbury, Vermont, which is described.

1982-01-01

428

Core preservation with a laminated, heat-sealed package  

Energy Technology Data Exchange (ETDEWEB)

A core preservation package was developed to maintain the reservoir characteristics of core samples and consequently to improve the quality of data obtained through laboratory core analyses. The package is a heat-sealable plastic-aluminum laminate similar to those common in the food-packaging industry. The laminated core preservation package acts as an impermeable barrier to water vapor and gases, and is resistant to chemical alteration and degradation by core fluids. These performance characteristics result in effective core preservation by maintaining the fluid content of the core. Other advantages of the laminated package are that it is fast and simple to use and eliminates the cumbersome dip-coat step used in some core preservation methods.

1988-12-01

429

A mathematical model for a thermally coupled humidification?dehumidification desalination process  

British Library Electronic Table of Contents (United Kingdom)

The humidification?dehumidification process is an interesting technique that has been adapted for water desalination. Previous works experimentally investigated desalination processes in the shell and tube columns, where the humidification and dehumidification were thermally coupled and simultaneously performed at the tube and shell sides, respectively. In this work, a comprehensive steady-state mathematical model was developed for such a humidification?dehumidification desalination process by taking into account the heat and mass balances on both sides of the desalting column, the mass transfer rate at the humidification side, and the heat transfer rate between the dehumidification side and humidification side. Meanwhile, the mass transfer coefficient at the humidification side and the to...

2006-01-01

430

Study on tritium activity build-up in moderator and primary heat transport systems in 540 MWe reactor  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by Deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on Tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-3 and 4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)

2006-11-13

431

Study on tritium activity build-up in moderator and primary heat transport (PHT) systems in 540 MWe reactor  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)

2005-11-23

432

Recriticality of a BWR core during reflood after control blade meltdown  

Energy Technology Data Exchange (ETDEWEB)

In nuclear reactor safety research, the question of the possible consequences of delayed core reflood during severe accidents or anticipated transient without scram transients in boiling water reactors (BWRs) has been raised. One can envisage a very low probability accident scenario leading to core uncovery and core heat-up, followed by control blade melting and subsequential delayed reflooding of the core with unborated water before its degradation. Reflooding of the hot core causes significant increases in the peak heating, melting, and hydrogen production rates, thus increasing the probability of core degradation. However, as has been established, debris beds formed from shattered fuel rods and quenched fuel melt will be undermoderated. The reflood process of a voided, intact core was examined using the TRAC/BFI CODE.

1994-12-31

433

Development of standard solutions for the Minergie standard; Standardloesungen - Entwicklung von Standardloesungen fuer den Minergie-Standard  

Energy Technology Data Exchange (ETDEWEB)

This final report for the Swiss Federal Office of Energy (SFOE) examines a project that aimed to define standard solutions for use in buildings built to meet Minergie low energy consumption standards. These standard solutions are to provide a way of meeting Minergie standards in an easy way and thus further the use of the standard and also assure quality at the same time. The report describes how the solutions were developed on the basis of a selection of existing Minergie buildings. For various combinations of heating systems - wood, wood/solar, heat pumps (brine-water and air-water), gas/solar and oil/solar - the appropriate U-values for various building elements are listed. The resulting Minergie forms and guides are listed.

2003-07-01

434

A model of chemistry and thermal hydraulics in PWR fuel crud deposits  

Energy Technology Data Exchange (ETDEWEB)

A model is described for simulating thermal hydraulic and chemical conditions within fuel crud deposits. Heat transfer takes place by wick boiling in which water flows through the porous deposit and evaporates into steam at the surface of chimneys. The transport and chemistry of dissolved species within the deposit is also modelled. This chemistry includes the equilibrium chemistry of Li/boric acid species, the equilibrium chemistry of Fe/Ni species and the radiolysis chemistry of water. The unique feature of this model is that the chemistry is coupled to the thermal hydraulics via the increase in the saturation temperature with the concentration of dissolved species. This has a profound effect on evaporative heat transfer within thick deposits, leading to conditions that explain the precipitation of LiBO{sub 2} and the possible formation of bonaccordite. The model helps understand several crud scrape ...

2006-07-01

435

The potential of solar-driven humidification-dehumidification desalination for small-scale decentralized water production  

Energy Technology Data Exchange (ETDEWEB)

World-wide water scarcity, especially in the developing world, indicates a pressing need to develop inexpensive, decentralized small-scale desalination technologies which use renewable resources of energy. This paper provides a comprehensive review of the state-of-the-art in one of the most promising of these technologies, solar-driven humidification-dehumidification (HDH) desalination. Previous studies have investigated many different variations on the HDH cycle. In this paper, performance parameters which enable comparison of the various versions of the HDH cycle have been defined and evaluated. To better compare these cycles, each has been represented in psychometric coordinates. The principal components of the HDH system are also reviewed and compared, including the humidifier, solar heaters, and dehumidifiers. Particular attention is given to solar air heaters, for which design data is limited; and direct air heating is compared to direct ...

2010-05-15

436

Pitting corrosion of copper coiled tubes in the air conditioning system having the open heat storage water tank; Kaihokei chikunetsuso reionsuika ni okeru kuchokiyo kokan no koshoku ni tsuite  

Energy Technology Data Exchange (ETDEWEB)

In order to investigate pitting corrosion of copper coiled tubes for air conditioning systems with an open heat storage water tank, the effect of carbon films on the inner surface of copper tubes and fine corrosion-product particles in water as environmental corrosion factor on pitting corrosion was studied by field test under real environmental conditions. As a result, pitting corrosion of copper tubes was caused by synergistic effect of fine corrosion-product particles in water and carbon films. Generation of pitting corrosion was derived from deposition of the films and particles, while considerable growth of pitting corrosion was dependent on the particles. Time variation of spontaneous electrode potential also showed the effect of the film and particle. Pitting corrosion potential was estimated to be nearly 100mV vs. SCE. The following measures against pitting corrosion were considered to be ...

1998-11-15

437

3D-nuclear heat generation in PCC-charcoal filter in TAPP-3 and 4  

International Nuclear Information System (INIS)

This paper deals with the calculations of 3D nuclear heat generation profile in the charcoal filter and subsequently the commencement time of Primary Containment Cleanup (PCC) system of 540MWe Pressurized Heavy Water Reactor (PHWR). Fuel failure is predicted due to overheating of the fuel under loss of Coolant Accident (LOCA) without Emergency Core Cooling System (LOCA without ECCS). Subsequently fission product gasses along with water vapours are released to Reactor Building (RB) atmosphere. Plate-out and water trapping mechanism stabilizes the concentration of significant fission products i.e. radioiodines in about 4 hours before being circulated through charcoal filters of Containment Cleanup system. After cleaning up the RB atmosphere, it is discharged to outside atmosphere through stack. The isotopes of radioiodine emit beta and gamma radiations. Gamma radiations are partly stopped within the ...

2006-11-13

438

Research on regimes transition of the boiling water two-phase flow in horizontal rectangular narrow heated channels  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: The heat transfer and flow in narrow channels has lots of advantages such as compact structure, high efficiency, design flexibility and so on. So it is widely used in the fields such as the new reactor core plate elements, the once-through stream generator, compact heat exchangers as well as electronic components. In recent years, more strong attentions have been attracted to the thermal-hydraulic characteristics and mechanism of the two-phase flow in narrow channels. As the flow regime characteristics of two-phase flow is fundamental one of them, the research on the two-phase flow regimes and the regime transitions in horizontal rectangular narrow heated channels can provide theoretical foundation and engineering directions to the whole research on the thermal-hydraulic characteristics and mechanism of the two-phase flow in narrow channels. The characteristics of two-phase flow regimes and ...

2005-07-01

439

Research on regimes transition of the boiling water two-phase flow in horizontal rectangular narrow heated channels  

International Nuclear Information System (INIS)

Full text of publication follows: The heat transfer and flow in narrow channels has lots of advantages such as compact structure, high efficiency, design flexibility and so on. So it is widely used in the fields such as the new reactor core plate elements, the once-through stream generator, compact heat exchangers as well as electronic components. In recent years, more strong attentions have been attracted to the thermal-hydraulic characteristics and mechanism of the two-phase flow in narrow channels. As the flow regime characteristics of two-phase flow is fundamental one of them, the research on the two-phase flow regimes and the regime transitions in horizontal rectangular narrow heated channels can provide theoretical foundation and engineering directions to the whole research on the thermal-hydraulic characteristics and mechanism of the two-phase flow in narrow channels. The characteristics of two-phase flow regimes and ...

2005-10-02

440

Spattering and Crackle of Hot Cooking Oil with Water: A Classroom Demonstration and Discussion  

Science.gov (United States)

Any student that has spent time in the kitchen knows that hot vegetable oil will pop and spatter violently after coming into contact with water such as that on the surface of foods (meat, fish, potatoes, etc.). This well-known effect can be used as an instructional resource to promote cooperative, active, and inquiry-based learning about central concepts of chemistry including boiling point, miscibility, and density of liquids. The starting point of the learning activity is a demonstration of (i) the effect of adding a drop of water to hot (as for cooking) vegetable oil and (ii) the effect of adding a drop of vegetable oil to hot water (near its boiling point). Intermolecular interactions, properties of vegetable oils, and a variety of other topics, such as the importance of other heat points (smoke, flash, and fire) for oils, the fundamental of the crackle test for checking the presence of ...

2009-11-01

441

Modeling of thermal and hydrodynamic aspects of molten jet/water interactions  

Energy Technology Data Exchange (ETDEWEB)

In order to predict the effect of a fuel-coolant interaction after a hypothetical core-melt-down accident, a phenomenological model has been developed to describe the thermal and hydrodynamic behavior of a high-temperature molten jet when it interacts with saturated or subcooled water in a film boiling regime. The mechanisms of jet-material erosion were analyzed by Kelvin-Helmholtz instabilities on the coherent column and by boundary layer stripping on the leading edge. The heat transfer coefficient, vapor-film thickness, and net steam generation, all of which strongly affect the jet-breakup behavior, were solved analytically. It was found that the jet breakup (or erosion) depends strongly on the steam generation from the jet/water interaction. The jet-breakup length (i.e., penetration distance) was found to be sensitive to the initial jet temperature, water subcooling, and the physical state of the ...

1989-01-01

442

The solar energy in Lebanon: an inexhaustible and economical energy  

International Nuclear Information System (INIS)

The article describes the energy in Lebanon. In 1995, 97% of the imported energy was based on hydrocarbons. Fuel and gas oil present 66% of the final energy. Air pollution is mainly caused by the transportation sector (vehicles and buses...) which presents 70% of the global atmospheric pollution. Renewable energy such as biomass, fossil energy, hydro-energy, solar energy... are also described. The solar energy was defined as a best solution that preserve health in Lebanon. The different applications of the solar for energy production is discussed: photovoltaic , thermal heating, sanitary hot water, electrical heaters, solar water heaters...In conclusion, solar heaters economize 80% of the annual energy expenses

1997-06-01

443

Pitting corrosion of copper and copper alloys. (Latest citations from the EI Compendex*plus database). Published Search  

Energy Technology Data Exchange (ETDEWEB)

The bibliography contains citations concerning the pitting corrosion of copper and copper alloys by different media, with some references to methods that protect against such corrosion. Included are factors contributing to the onset of pitting corrosion. Emphasis is placed on exposure to water, especially in heat exchanger tubing and water conduits. Studies are included which examine corrosion in metals containing small amonts of copper where corrosion is attributable to changes in alloying. (Contains a minimum of 158 citations and includes a subject term index and title list.)

1994-04-01

444

Lightweight bricks manufactured from water treatment sludge and rice husks.  

Science.gov (United States)

Novel lightweight bricks have been produced by sintering mixes of dried water treatment sludge and rice husk. Samples containing up to 20 wt.% rice husk have been fired using a heating schedule that allowed effective organic burn-out. Rice husk addition increased the porosity of sintered samples and higher sintering temperatures increased compressive strengths. Materials containing 15 wt.% rice husk that were sintered at 1100 degrees C produced low bulk density and relatively high strength materials that were compliant with relevant Taiwan standards for use as lightweight bricks. PMID:19596512

2009-06-17

445

Hot water from the sun; Increasing awareness of energy saving considerations - thermal solar systems booming. Heisses Wasser von der Sonne; Umweltbewusster Umgang mit Energieressourcen findet immer mehr Anhaenger - Boom fuer thermische Solarsysteme  

Energy Technology Data Exchange (ETDEWEB)

Thermal solar energy plants for water heating have experienced an enormous boom during the last years. Thus, a total of 200000 square metres of collector surface was installed on German rooves in 1991. This was three times as much as in the year before. And this trend of conserving natural resources by using the energy of the sun is still undiminished. (orig.)

1993-11-01

446

Daya Bay gets underway  

International Nuclear Information System (INIS)

Unit one of Daya Bay, China's first nuclear power plant was officially opened in February 1994. The nuclear island has been built by Framatome and is an improved version of the Gravelines 5 and 6, 900MWe Pressurized Water Reactors. Extra seismic protection has been included because of greater earthquake risk. The heat exchanger capacity has also been increased as the sea cooling water can be at 30"oC. The technical specifications and details of the fuel loading are given. The technical assistance, management and training of Chinese personnel are discussed. Two further units may be built if Daya Bay 1 is successful. (UK).

447

Causes of denting. Volume 5. Contaminant threshold tests. Final report  

Science.gov (United States)

Steam generators in PWR plants have been subject to denting corrosion as a result of nonprotective magnetite forming on the carbon steel support plate causing the voluminous corrosion product that eventually crimps (dents) the heat transfer tube at the support plate interface. This project was designed to determine the causes of denting and the usefulness of water chemistry changes meant to arrest denting. This volume of the final report describes laboratory research on the correlation of water chemistry, superheat, and oxygen ingress with denting in steam generators.

1983-12-01

448

A horizontal steam generator for the Indian 235 MW heavy water nuclear power plants  

International Nuclear Information System (INIS)

In this paper the thermal design of a horizontal steam generator for the Indian PHWR nuclear power plant is described. The main attraction is absence of tube sheet and use of stainless steel 'U' tubes. It is emphasised that with appropriate water chemistry it is possible to use stainless steel tubes, which is many times cheaper than the Incoloy tubes used elsewhere. The design approach, applicable equation for the design and the results of computation in the form of heat transfer area and some important dimensions of the steam generator are presented.

1993-11-01

449

Effect of design improvements in heavy water management systems to reduce heavy water losses and tritium releases at Wolsong 2,3 and 4  

International Nuclear Information System (INIS)

Design improvements are being incorporated into the heavy water management systems at Wolsong 2,3 and 4 to reduce the load on the vapour recovery driers and upgraders and the heavy water losses via the stack. There will also be improvements to monitor heavy water and tritium releases. This paper describes the improvements, gives background on heavy water balance mechanism, the historical trends for heavy water recovery/losses and estimated dose to the member of the public critical group resulting from the airborne and waterborne releases. The measured tritium activity levels in the heat transport system (HTS) and moderator system at Wolsong 1 are given. Using these activity levels and heavy water loss data, tritium losses from the dried and ventilated areas are estimated. A qualitative assessment of expected heavy water ...

1994-03-01

450

Utilization of geothermal energy in the USSR  

International Nuclear Information System (INIS)

This paper reports that at present geothermal energy is utilized in the USSR mostly for district heating, and for industrial and agricultural purposes. The populations of 7 towns have district heating that is supplied by thermal waters. The population supplied totals about 125,000 people. The total area of greenhouses is 850,000 m"2. Electric energy generated at geothermal power stations still remains negligible with the installed capacity of the single Pauzhetka station (Kamchatka) being 11 MW. another station at Mutnovka is currently under construction and is expected to be producing 50 MW by 1992 and 200 MW by 1998. The proven geothermal resources in the USSR provide hope for a significant increase in the utilization of the earth's deep heat in the near future.

1990-08-20

451

The importance of axial effects for borehole design of geothermal heat-pump systems  

Energy Technology Data Exchange (ETDEWEB)

This paper studies the effects of axial heat conduction in boreholes used in geothermal heat pump systems. The axial effects are examined by comparing the results obtained using the finite and infinite line source methods. Using various practical design problems, it is shown that axial effects are relatively important. Unsurprisingly, short boreholes and unbalanced yearly ground loads lead to stronger axial effects. In one example considered, it is shown that the borehole length is 15% shorter when axial conduction effects are considered. In another example dealing with underground water freezing, the amount of energy that has to be removed to freeze the ground is three times higher when axial effects are considered. (author)

2010-04-15

452

Research on the preparation of coal water fuel (CWF) from Banko coal, south Sumatera  

Energy Technology Data Exchange (ETDEWEB)

Studies of CWF preparation at laboratory scale have been carried out using the type and amount of additives and coal content as process variables. Other factors such as particle size, time and rate of stirring were kept constant. CWF with 45 wt% of dry solids, heating value of 5,475 BTU/lb, and stable without the evidence of sedimentation for 9 weeks have been obtained using carboxy methyl cellulose (CMC) as the additive. Low coal content and low heating value can be increased by hydrothermal process on the elevated temperature and pressure. By this process, CWF with dry solid of 55 wt% and a heating value of 7,125 BTU/lb could be obtained. 6 refs., 8 figs., 2 tabs.

1994-01-01

453

Precipitation mechanisms and subsequent hardening kinetics in the #beta#-CEZ alloy  

International Nuclear Information System (INIS)

The #beta#-CEZ alloy : Ti-5%Al-2%Sn-4%Zr-4%Mo-2%Cr-1%Fe is a near #beta# titanium alloy. Since its processing routes include heat treatment (consisting of solution treatment and ageing), it has been decided to study the influence of the #beta# phase stability on #alpha# phase precipitation and hardening kinetics. Small sized specimens, coming from industrial heats, have been heat treated above and below the #beta# transus, and then water quenched. Therefore, several degree of #beta# stability are obtained. When it is increased (i.e. the solution treatment temperature is lowered), #alpha# or #omega# phases precipitations are delayed, as well as the hardening phenomena. Moreover, the #omega# stability domain is reduced. The mechanisms of #alpha# or #omega# precipitation are discussed, and related to the hardening kinetics. (orig.).

454

Clean combustion of solid fuels  

International Nuclear Information System (INIS)

A chemical-looping process is proposed for the clean combustion of solid fuels for electric power or heat generation. The process is based on coal gasification with CO_2 to produce CO. The CO then reduces CaSO_4, which is used as an oxygen carrier, in a separate reactor to give CaS and CO_2. A portion of the CO_2 is recycled for the gasification stage and the rest can be sent for sequestration. The CaS is sent to another reactor for oxidation with air and to generate heat or power. The overall thermal effect is the same as direct combustion, but separation of CO_2 and other pollutants, such as sulphur, is achieved. In comparison with conventional chemical-looping combustion of natural gas, much less water is present in the CO_2 product, and hence the loss of heat energy and corrosion of the fuel-reactor system can be reduced.

2008-01-01

455

Causes of denting. Volume 1. Summary report. Final report  

Science.gov (United States)

This summary report outlines the work that was performed to gain a more complete understanding of denting corrosion of steam generators in PWRs. Background laboratory and plant data on denting were compiled, reviewed and correlated to determine how various exposure conditions affect denting. Two high-temperature chemistry analytical models were reviewed and evaluated by experimental simulation of impurity concentration in the heat transfer and isothermal capsule tests. Simulation of impurity concentration for three cooling waters (lake, river, and cooling tower) was evaluated. The effects of species concentration (Cu/sup + +/, Cl/sup -/, O/sub 2/, and H/sup +/), contaminant thresholds (established by isothermal and heat transfer tests), and heat flux as indicated by superheat on denting were examined. A discussion of several pertinent observations and conclusions drawn from these tasks (as they pertain ...

1984-05-01

456

Analysis of plasma treatment and vapor heat treatment for thin-film transistors by extracting trap densities at front and back interfaces  

International Nuclear Information System (INIS)

Hydrogen (H) plasma treatment, oxygen (O) plasma treatment and water (H_2O)-vapor heat treatment for polycrystalline-silicon (poly-Si) thin-film transistors (TFTs) have been analyzed by separately extracting trap density at a front silicon-oxide interface (D_F) and trap density at a back interface (D_B). It is found that the H plasma treatment is apt to generate D_F and D_B. The O plasma treatment reduces D_F, while the H_2O-vapor heat treatment reduces both D_F and D_B. Improvement of transistor characteristics of poly-Si TFTs depends on understanding these results.

2004-05-17

457

The effects of gaseous environments on the mechanical failure of polyethylene pipe materials. Annual technical report 1 Nov 80-31 Oct 81  

Energy Technology Data Exchange (ETDEWEB)

Polyethylene gas piping is expected to be in service for times on the order of 50 years depending on service conditions. Therefore research research on piping materials and pipes has two principal objectives: (a) developing methods for predicting when a pipe will fail and (b) improving the material for piping. The prediction of long time failure hinges on the development of short time test methods which relate to long time failure. The improvement in the behavior of current materials also hinges on the use of test methods of short duration relative to the anticipated life time of the pipe in service. One of the primary criterion for an acceptable test method is that it produces the same type of failure as is observed after long time failure in service. It has been found that P.E. pipe material fails in a brittle mode after long periods of ...

1981-10-01

458

Study on potential threats against the leak tightness of the reactor containments due to pipe whips from hypothetical pipe ruptures in the steam- and feedwater systems; Utredning angaaende potentiella hot mot inneslutningars taethet paa grund av roerslag fraan taenkta roerbrott i aang- och matarvattenledningar  

Energy Technology Data Exchange (ETDEWEB)

Possible threats against the leak tightness of the reactor containments, due to pipe whips from hypothetical pipe ruptures in the steam- and feedwater systems, have been investigated for Forsmark 3/Oskarshamn 3, Ringhals 1, Oskarshamn 1 and Barsebaeck 2/Oskarshamn 2. Based on available drawings, such as installation drawings and isometric views of pipes, the pipe systems have been put together in new drawings with their bracing supports and containment walls. This inventory shows that pipe whips can occur on a number of places on the containments walls after hypothetical pipe ruptures in the steam- and main feedwater systems. In order to find out whether these pipe whips are real threats against the leak tightness, further analysis needs to be made but are out of the scope of this investigation.

2001-03-01

459

GDH pipe break transient analysis of the RBMK - 1500.  

Energy Technology Data Exchange (ETDEWEB)

Presented in this paper is the transient analysis of a Group Distribution Header (GDH) following a guillotine break at the end of the header. The GDH is the most important component of reactor safety in case of accidents. Emergency Core Cooling System (ECCS) piping is connected to the GDH piping such that, during an accident, coolant passes from the GDH into the ECCS. The GDH that is propelled into motion after a guillotine break can impact neighboring GDH pipes or the nearest wall of the compartment. The cases of GDH impact on an adjacent GDH and its attached piping are investigated in this paper. A whipping RBMK-1500 GDH along with neighboring concrete walls and pipelines is modeled using finite elements. The finite element code NEPTUNE used in this study enables a dynamic pipe whip structural analysis that accommodates large displacements and nonlinear material characteristics. ...

2002-05-15

460

UNSAT-H Version 3.0: Unsaturated Soil Water and Heat Flow Model Theory, User Manual, and Examples  

Energy Technology Data Exchange (ETDEWEB)

The UNSAT-H model was developed at Pacific Northwest National Laboratory (PNNL) to assess the water dynamics of arid sites and, in particular, estimate recharge fluxes for scenarios pertinent to waste disposal facilities. During the last 4 years, the UNSAT-H model received support from the Immobilized Waste Program (IWP) of the Hanford Site's River Protection Project. This program is designing and assessing the performance of on-site disposal facilities to receive radioactive wastes that are currently stored in single- and double-shell tanks at the Hanford Site (LMHC 1999). The IWP is interested in estimates of recharge rates for current conditions and long-term scenarios involving the vadose zone disposal of tank wastes. Simulation modeling with UNSAT-H is one of the methods being used to provide those estimates (e.g., Rockhold et al. 1995; Fayer et al. 1999). To achieve the above goals for assessing water dynamics and estimating ...

2000-06-12

461

The cooperative housing society Vaarst Vestervang - green building; Andelsboligforeningen Vaarst Vestervang - groent byggeri  

Energy Technology Data Exchange (ETDEWEB)

Vaarst Vestervang (Denmark) comprises 16 villas and 1 communal building. The complex was designed by the inhabitants themselves with the aim of polluting the environment as little as possible. The land area constitutes 69.000 square meters where it is possible to grass animals. The document reports a measuring programme concerning the overall heat consumption as one of the main aims of the inhabitants is to save energy and thus contribute to the protection of the environment. The capacity of the solar collectors predominantly used in the building complex was 235 kWh/m{sup 2}. Supplementary heating is provided by boilers fired with wood. The measuring system is described in detail. Tables show the influence of heat transmission losses, ventilation, airing out of rooms, the angle of the sun`s rays within the buildings and heating needs on energy consumption. Energy consumption data is presented in ...

1993-10-01

462

Interface heat transfer of horizontal co-current liquid-liquid stratified flow. II - Entrance region  

Science.gov (United States)

Flow structures and heat transfer at the liquid-liquid interface are investigated experimentally and analytically in the entrance region of a liquid metal-water stratified flow in a horizontal rectangular channel. The two-equation model and the mixing length mode, including a damping turbulent region near the interface, are used to obtain analytical results for pressure drop, position of the interface, and heat transmission coefficients across the interface. Analytical results are compared with experimental results. Conclusions are presented and include the following: (1) vertical position of the interface increases or decreases along the stream according to the fluid flow rate of both fluids, and then approaches a constant value in the fully developed region; (2) pressure drop increases along the stream from the minimum value at the inlet; and (3) heat transmission coefficients across the interface ...

1981-06-01

463

Integrated numerical modeling of surface-subsurface-coupled, 2-phase fluid/heat flow in limnological system 1. New type of modeling and experimental study; Shizen suirikei no ryutai{center_dot}netsu ido togo moderingu no kokoromi 1. Ryutai{center_dot}netsu ido no atarashii teishikika to jikkenteki kento  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the comprehensive modeling method of fluid and heat flows in the hydrological system. Based upon the concept that the hydrological system is composed of the air-water 2-phase fluids, and the rock phase, various natural processes are modeled including surface/subsurface 2-phase mass transfer, heat exchanges between fluid phases, between fluid and solid phases, and sensible/latent heat exchanges on the ground surface. A field-oriented numerical simulator is developed, in which a set of governing equations is solved for different variables on the surface and in subsurface regions, respectively. Results of an experimental study are presented, in which transient formulation of heat exchange between fluid/solid phases is examined through matching of the observation and calculated performances. (author)

1999-08-31

464

Integrated numerical modeling of surface-subsurface-coupled, 2-phase fluid/heat flow in limnological system 1. New type of modeling and experimental study. Shizen suirikei no ryutai[center dot]netsu ido togo moderingu no kokoromi 1. Ryutai[center dot]netsu ido no atarashii teishikika to jikkenteki kento  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the comprehensive modeling method of fluid and heat flows in the hydrological system. Based upon the concept that the hydrological system is composed of the air-water 2-phase fluids, and the rock phase, various natural processes are modeled including surface/subsurface 2-phase mass transfer, heat exchanges between fluid phases, between fluid and solid phases, and sensible/latent heat exchanges on the ground surface. A field-oriented numerical simulator is developed, in which a set of governing equations is solved for different variables on the surface and in subsurface regions, respectively. Results of an experimental study are presented, in which transient formulation of heat exchange between fluid/solid phases is examined through matching of the observation and calculated performances. (author)

1999-08-31

465

Drying characteristics and nitrogen loss of biogas digestate during drying process  

Energy Technology Data Exchange (ETDEWEB)

The cost of transporting biogas digestate can be decreased by reducing its water content. However, the digestate emits volatile compounds during drying. This study investigated the drying behaviour and the change of digestate composition. Drying took place in a hybrid solar/waste-heat dryer that used solar energy as well as waste heat from a combined heat and power unit (CHP) and the exhaust air of a microturbine. The experiment involved the use of 60 t of liquid digestate. Climatic conditions were measured inside and outside the drying hall. Dry matter (DM) and organic dry matter (ODM) were also measured on a daily basis. In addition, the energy consumption of waste and solar heat were recorded and related to the quantity of dried feedstock. The total nitrogen, ammonium, phosphate, potassium oxide, magnesium oxide and calcium oxide in the digestate were subjected to chemical ...

2010-07-01

466

Heat management - a technique for resolving the conflicting aims between fuel consumption and comfort; Waermemanagement - ein Werkzeug zur Loesung der Zielkonflikte zwischen Verbrauch und Komfort  

Energy Technology Data Exchange (ETDEWEB)

In view of current trends in motor car development, the author investigates the increasing conflict between higher comfort and lower fuel consumption. The conflict results mainly from insufficient cooling water heating with consumption-optimized engines. So far, it was never necessary to analyze heat flow after cold starting and heat-up of the powertrain, to develop strategies for heat storage and distribution, to remove heat sinks and to use components multifunctionally. The contribution shows that a general heat management strategy for the whole vehicle will result in high potential fuel savings and improved thermal comfort. Using the example of a latent heat store, heating strategies for the engine and transmission system on the one hand and the passenger compartment on the other hand are ...

1999-07-01

467

Sensitivity Study for CFD Analysis on Debris Transport to ECCS Sump for CANDU Type Plant in Korea  

International Nuclear Information System (INIS)

Once containment recirculation pumps are activated and emergency core cooling (ECC) flow is supplied from the recirculation sump during loss of coolant accident (LOCA), various insulations and coatings on a pipe, equipments and structures damaged by LOCA break jet as well as additional debris sources are transported to recirculation sump screen by the break flow and containment spray flow drainage. This debris may result in loss of net pressure suction head (NPSH) of the recirculation pumps, and have a threat to long term cooling and containment heat removal capacity. In this case, flow patterns of containment pool are important to confirm behaviors of debris transport for predicting various flow paths to the recirculation sump screen. In this paper, models using commercial computational fluid dynamics (CFD) software CFX are developed for containment pool simulation during recirculation mode. The specific plant used for this analysis is CANDU ...

2010-10-01

468

PWM applications for the electric railway traction system fed by the AC/DC dual power line  

Energy Technology Data Exchange (ETDEWEB)

The latest electronic circuit technology that can be used for the electric railway traction system fed by an AC/DC dual power line was developed. This system consists of reverse conducting GTO thyristors, microprocessors, and DSP`s. In the AC power supply line section, the line converter is controlled by PWM technology to secure a high power factor and reduce the higher harmonic generation of an input current as far as possible. The line converter and motor converter use reverse conducting GTO thyristors. Since these converters are cooled using a heat pipe cooler, they are reduced in size and weight. The electric grounding point of the main power circuit is set to the negative side of the DC line for AC and DC line sections. Therefore, the AC/DC selector switch was simplified in structure. Moreover, the DC input for the auxiliary power supply can be obtained from multiple line converters using diodes. As the result of the actual operational ...

1996-01-01

469

Four loss-of-flow accidents in the SEAFP first wall/blanket cooling system  

Energy Technology Data Exchange (ETDEWEB)

This report presents the thermal-hydraulic analysis of four Loss-of-Flow Accidents (LOFAs) in the first wall/blanket cooling system of the alternative SEAFP reactor design. The LOFAs considered result from a loss of electrical power for the recirculation pump in the primary cooling circuit. The analyses have been performed using the thermal-hydraulic system analysis code RELAP5/MOD3. In the analyses, special attention has been paid to the transient thermal-hydraulic behaviour of the cooling system and the temperature development in the first wall and blanket. For the LOFA without plasma shutdown, significant loss of heat removal due to dryout occurs at the midplane of the outboard first wall cooling pipes about 41 s after pump trip. For the three LOFA cases with emergency plasma shutdown that have been studied, the temperature increase in the Be-coating at the midplane of the outboard first wall is limited to about 30 K. (orig.).

1994-07-01

470

Fatigue and creep crack growth behaviour at high temperatures for weld metals of Alloy 800 and Alloy 617  

International Nuclear Information System (INIS)

High temperature fatigue crack growth (FCG) and creep crack growth (CCG) experiments have been conducted in air on weld metal, heat affected zone (HAZ) and base metal of the austenitic Alloy 800 and the nickel base Alloy 617. Tests were performed on specimens machined from pipes, in the temperature range 550-900 deg. C. The crack propagation mode was examined. At all temperatures and for both materials, FCG of base metal was found to be the highest, whereas the weld metal exhibited the lowest FCG rate. The FCG rate in the HAZ was found to lie in between of those observed for base and weld metal. The crack propagation mode remained transgranular in base metal and transdendritic in weld metal at all temperatures. CCG behaviour could be described using the energy rate integral C*. Base metal and weld metal exhibited similar CCG rate at same C*. The crack propagation mode under CCG condition was found to be intergranular in base metal and HAZ and ...

1993-08-15

471

Extracting energy from hydraulically-fractured geothermal reservoirs  

Science.gov (United States)

The governing equations for heat and mass transfer were derived for hydraulically fractured geothermal reservoirs. When converted to nondimensional form it was shown that the equations can be considerably simplified. The resulting equations can be strongly influenced by the effects of buoyancy; the magnitude of the effect is measured by the ratio of the Grashof and Reynolds numbers, and the ratio of the actual permeability of the fracture and the square of the fracture gap width. Significant quantities of energy can be extracted from hydraulic fractures--even without thermal stress fracturing. The amount is limited by the size of the fracture and the low thermal conductivity of rock. The viscous pressure drop in open fractures is insignificant, and depending upon losses in piping and surface equipment, the entire system could be ''self-pumped'' due to buoyancy. Thermal contraction of the rock tends to ...

1976-01-01

472

Effect of primary air content on formation of nitrogen oxides during combustion of Ehkibastuz coal  

Energy Technology Data Exchange (ETDEWEB)

Investigations are discussed carried out in a pilot plant at the Kaz. Power Engineering Scientific Research Institute into the effect of the amount of primary air in coal-dust flame on the final concentration of nitrogen oxides in flue gases. The tests were carried out in a 7500 mm high, 1600 mm dia vertical cylindrical combustion chamber having type P-57 burner, and air dispersed fuel plus additional air supplies located at the top. Amounts of coal dust fed by a drum feeder along the air pipe varied from 100-600 kg/h. The required air was supplied by 5000 m/sup 3//h Type TK-700/5 blowers at 0.04 MPa. Ehkibastuz coal samples contained: 1.3% moisture; 48.1% ash; 38.02% carbon; 2.56% hydrogen; 0.73% sulfur; 0.60% nitrogen; heat of combustion was 14.3 MJ/kg. Results obtained indicate that variations in the amount of primary air in swirl flow burners affect formation of fuel nitrogen; there is an optimum volume at which minimum quantities of ...

1986-01-01

473

Advanced solution algorithms for transient multidimensional thermohydraulic flow problems in complex geometries with the programme COMMIX-2/KfK  

Energy Technology Data Exchange (ETDEWEB)

The computer programme COMMIX-2 describes steady state and transient multidimensional single- and two-phase fluid flows with heat transfer in nuclear reactor components and multicomponent systems. Originally from the Argonne National Laboratory, the code has been further developed at the Kernforschungszentrum Karlsruhe. The original Point-SOR iterative method for the solution of a Poisson-like equation describing the pressure distribution in the fluid as well as the transport of enthalpy and turbulent quantities has been complemented with iterative and direct line- and block-methods. None of the newly implemented methods is original in itself but their implementation into the computer code, which can describe the most general shapes of definition domains, gave a code speed-up by a factor of 2-5, depending on the problem treated. The code capabilities are assessd by the calculation of a benchmark problem involving the numerical simulation of thermal buoyancy ...

1987-03-01

474

Advanced solution algorithms for transient multidimensional thermohydraulic flow problems in complex geometries with the programme COMMIX-2/KfK  

International Nuclear Information System (INIS)

The computer programme COMMIX-2 describes steady state and transient multidimensional single- and two-phase fluid flows with heat transfer in nuclear reactor components and multicomponent systems. Originally from the Argonne National Laboratory, the code has been further developed at the Kernforschungszentrum Karlsruhe. The original Point-SOR iterative method for the solution of a Poisson-like equation describing the pressure distribution in the fluid as well as the transport of enthalpy and turbulent quantities has been complemented with iterative and direct line- and block-methods. None of the newly implemented methods is original in itself but their implementation into the computer code, which can describe the most general shapes of definition domains, gave a code speed-up by a factor of 2-5, depending on the problem treated. The code capabilities are assessd by the calculation of a benchmark problem involving the numerical simulation of thermal buoyancy ...

1987-01-01

475

Advanced PWR technology development -Development of advanced PWR system analysis technology-  

Energy Technology Data Exchange (ETDEWEB)

The primary scope of this study is to establish the analysis technology for the advanced reactor designed on the basis of the passive and inherent safety concepts. This study is extended to the application of these technology to the safety analysis of the passive reactor. The study was performed for the small and medium sized reactor and the large sized reactor by focusing on the development of the analysis technology for the passive components. Among the identified concepts the once-through steam generator, the natural circulation of the integral reactor, heat pipe for containment cooling, and hydraulic valve were selected as the high priority items to be developed and the related studies are being performed for these items. For the large sized passive reactor, the study plans to extend the applicability of the best estimate computer code RELAP5/MOD3 which is widely used for the safety analyses of the reactor system. The improvement and ...

1995-07-01

476

Topical Report ''Corrosion Evaluation of LLW2 Skid-B Weld Failure Mechanisms (44139-92)  

Energy Technology Data Exchange (ETDEWEB)

An independent investigation of pipe welding leaks from the Low-Level Waste 2 (LLW2) Skid-B System for the possibilities of improper welding (IW), microbiologically influenced corrosion (MIC), sensitization, chloride pitting corrosion (CPC), and intergranular stress corrosion cracking (IGSCC) was conducted. The results show the prevailing mechanisms that caused the leaks are identified as IW, CPC, and the improper selection of weld filler material for the base metals in an environment of the North Plateau underground water. These is no evidence of MIC, sensitization, or IGSCC. The chloride pitting corrosion mechanism that took place at all the welds are also described. All the pipelines were replaced with polyvinyl chloride (PVC) for cost saving and the LLW2 Skid B System has been successfully operating since 1999. This report summarizes the findings and recommendations associated with preventive measures for future operations. The LLW2 ...

2001-05-31

477

WIPS: computer code for whip and impact analysis of piping systems. Summary report  

Energy Technology Data Exchange (ETDEWEB)

WIPS (Whip and Impact of Piping Systems) is a special purpose computer code for the structural analysis of pipe whip dynamic effects following a postulated pipe rupture. WIPS has been developed primarily to provide support for the pipe whip analysis procedures described in Section 3.6.2 of the US Nuclear Regulatory Commission Standard Review Plan. This report summarizes the purpose and scope of the WIPS development effort, identifying those clauses in the Standard Review Plan which refer to pipe whip analysis, and indicating how the WIPS code can be used to provide supporting data. Detailed information on use of the code is contained in accompanying reports which cover: (1) user instructions; (2) theory; (3) programming procedures; and (4) verification examples.

1984-06-01

478

Development of the Precarbon process  

Science.gov (United States)

The Precarbon process has been developed jointly by the Bergbauforschung Institute and the Federal German company, Didier. The characteristic feature of the process is the combination of two-stage coal heating in pipe dryers to 200/sup 0/C and its smokeless charging to the coke ovens by means of a Redler conveyor passing over the coke oven battery. Calculations have shown that the use of preheated coal can be justified economically in three cases: (1) To increase coke oven battery outputs. When using standard coals the battery throughput increase of approximately 45% due to coal preheating reduces costs for coking in comparison with wet coal coking, which would require larger coke ovens. (2) To improve coke quality. Use of preheated coal produces a blast furnace coke of the required quality from charges containing increased weakly-coking coal contents. 3. To increase output from coke oven batteries being rebuilt. A recent development of the ...

1980-01-01

479

Gibbs ensemble Monte Carlo simulations of coexistence properties of a polarizable potential model of water  

Energy Technology Data Exchange (ETDEWEB)

The liquid/vapor coexistence density, the partial vapor pressure, and the heat of vaporization were calculated using Gibbs ensemble Monte Carlo simulation techniques. Long-range interactions such as charge-charge, charge-dipole, and dipole-dipole were evaluated using Ewald summation techniques. A polarizable potential model was used to describe the water-water interactions (Dang and Chang, J. Chem. Phys. 106, 8149, 1997). The model yields good agreement with the corresponding experimental data in the lower temperature region and moderate agreement in the higher temperature region. The critical temperature and density were estimated to be 565 K and 0.28 g/cm3.

2001-12-01

480

Evaporation behavior of water and concentration of technetium and rhenium using thin film evaporator  

International Nuclear Information System (INIS)

The nuclear energy cycle requires the recycling of nuclear fuel, water, chemical reagents, and the volume reduction of radioactive liquid wastes. A fundamental technique for continuous recovery of water using a thin-film evaporator was examined. Appropriate recovery measurements were: an evaporator heat temperature of 323 K, a feed rate of 0.23 cm"3 x s"-"1, a vacuum pressure of 15 mmHg (2 kPa), and impeller rotational speeds of 500#approx#600 rpm (min"-"1). The concentration of trace technetium and rhenium in aqueous solutions was also studied. A decontamination factor of 10"5 for rhenium was obtained. (author)

1999-06-01

481

Estimation of dry rubber content in natural rubber latex by differential scanning calorimetry  

British Library Electronic Table of Contents (United Kingdom)

Differential Scanning Calorimetry (DSC) is employed to study the changes in enthalpy of natural rubber latex samples when heated under a controlled temperature program. It is found that the mass normalized areas of the DSC curves between room temperature and 170??C for different latex samples are inversely proportional to the dry rubber content (DRC) of the samples, measured following the weighing and drying method. The changes in total enthalpy of the samples in this temperature range are interpreted as due to the variations in the quantity of water present in the samples. The measurements have been repeated by diluting selected samples with known quantities of water, and it is found that the normalized areas of the DSC curves are directly proportional to the amount of water added to the ...

2010-01-01

482

Radiation-polymerizable mixture and recording material containing it  

International Nuclear Information System (INIS)

Esters of dihydric alcohols with alkenylphosphonic or alkenylphosphinic acids which are polymerizable by free radicals are described. They are combined with polymer binders, in particular water-soluble polymers, and photoinitiators forming free radicals to give photopolymerizable mixtures which are suitable for the production of photoresists and printing plates. The mixtures display low heat-sensitivity and have long shelf lives. (author) 1 tab.

1991-01-01

483

Growth model and on-line measurement of pitting corrosion on carbon steel  

Energy Technology Data Exchange (ETDEWEB)

A growth model of pitting corrosion of carbon steel in cooling water systems was developed on microscopic observations of pits and electrochemical studies. Results of pitting corrosion measurements in laboratory and field conditions with the model, using a newly developed electrochemical device, are discussed. For an actual heat exchanger up to a year operation, the values of pitting depth estimated were in good agreement with the measured values.

1996-12-01

484

Environmental effects and energy efficiency in building design - a green building approach. Pt. 1. Energy efficiency techniques  

Energy Technology Data Exchange (ETDEWEB)

A research report describes the energy efficiency techniques to be employed in designing a building which is ``green``. Topics covered include building fabric performance, ventilation and infiltration, passive solar design, heating systems and controls, hot and cold water provision, lighting and electrical appliances. (UK)

1993-12-31

485

Comparing Maintenance Costs of Geothermal Heat Pump Systems with other HVAC Systems in Lincoln Public Schools: Repair, Service, and Corrective Actions  

Energy Technology Data Exchange (ETDEWEB)

The Lincoln Public School District, in Lincoln, Nebraska, recently installed vertical-bore geothermal heat pump systems in four, new, elementary schools. Because the district has consistent maintenance records and procedures, it was possible to study repair, service and corrective maintenance requests for 20 schools in the district. Each school studied provides cooling to over 70% of its total floor area and uses one of the following heating and cooling systems: vertical-bore geothermal heat pumps (GHPs), air-cooled chiller with gas-fired hot water boiler (ACUGHWB), water-cooled chiller with gas-fired hot water boiler (WCCYGHWB), or water-cooled chiller with gas-fired steam boiler (WCUGSB). Preventative maintenance and capital renewal activities were not included in the available database. GHP schools reported average total costs at 2.13 ...

1999-06-19

486

Capturing sun for car and house; Fanger sol til bil og hus  

Energy Technology Data Exchange (ETDEWEB)

Solar panels have been installed at the roof, providing enough power to drive electric cars 20 000 kilometres yearly, while water-borne heating in the household has reduces electricity demand by 12-13 000 kWh per year

2008-07-01

487

Transient Critical Heat Flux tests on a rod bundle simulating Pressurized Water Reactors  

International Nuclear Information System (INIS)

Transients induced in nuclear power plants from many sources result in one or more fluid conditions changing with time. Fluid conditions of pressure, inlet temperature, inlet flow, or even system power many change separately or in conjunction with each other. The result of the condition change may be one which induces departure from nucleate boiling. An experimental investigation of transient which were intended to achieve Critical Heat Flux was performed at the Heat Transfer Research Facility of Columbia University for Siemens Nuclear Power Corporation. The transients were set up to include broad ranges of flow and pressure conditions near the operating range of pressurized water reactors. Transient events were dominated by varying single conditions and measuring the response of the system and of the rod thermocouples. Because of coupling effects within the test loop, secondary conditions would also vary. In order to ...

488

A Scheme of 3-D Breakdown-whip Analysis Methodology for High Energy Piping  

Energy Technology Data Exchange (ETDEWEB)

High energy piping systems are operated with either or both conditions of maximum operating temperature exceeding 200 .deg. F(93.3 .deg. C) or maximum operating pressure exceeding 275 psig(19.3kg/cm{sup 2}) during normal operating conditions in nuclear power plants. A high energy pipe failure is postulated in branches or piping that runs larger than one inch nominal diameter. The resultant consequences of these postulated pipe breaks must be analyzed for the effect on maintenance of plant safe shutdown capability, containment integrity. And the analyzed results must be applied to the system design so that a pipe failure can not damage essential systems to an extent of impairing design function nor affect necessary component operability. The considerable effects of pipe break are as follows; dynamic effects such as pipe whip, jet impingement ...

2007-10-15

489

Water contents of samples from the Nevada Test Site: total, free (natural state to 105/sup 0/C), and more tightly bonded (105 to 700/sup 0/C)  

Energy Technology Data Exchange (ETDEWEB)

To help confirm correct functioning of an epithermal neutron sonde, we measured tightly bonded water content of selected Nevada Test Site (NTS) drill holes. Tuff and alluvium samples were dried overnight at 105/sup 0/C. The samples were then heated for 45 min in a split tube furnace at 700/sup 0/C. The water that came off due to this heating was collected and the amount recorded. The error in this procedure is +- 0.59 wt %. Total water can be calculated for samples from analyses of free and tightly bonded water contents. The maximum error in this calculation is equivalent to the error in determining the more tightly bonded water. Average total water content values have been assigned to geologic units. These values, in weight fraction, are alluvium 0.14 +- .05 and tuff 0.19 +- .04. Further division of the tuff gives ...

1981-05-01

490

Relaxation and corrosion resistance of alloy 800 used for steam generator tubes of ship borne boilers  

Energy Technology Data Exchange (ETDEWEB)

The INCO ``INCOLOY 800`` trademark groups the Fe-Cr-Ni alloys containing 30 to 35% nickel, 19 to 23% chromium, 0,15 to 0,60% aluminium, 0,15 to 0,60% titanium and less than 0,10% carbon contents, used as construction materials for condenser and heat exchanger tubes. In parallel with water chemistry control and studies aimed at reducing the residual stresses resulting from tube expansion, studies have been conducted to a better understanding of this alloy, its metallurgy and its corrosion behaviour under accurately defined fabrication and heat treatment conditions. The purpose of this paper is to present the results of a behaviour study of INDRET alloy 800 concerning isothermal relaxation and effects of the said relaxation heat treatments on alloy microstructure studied with a transmission electron-chemical method to determine the sensitiveness to intergranular corrosion, and by electrochemistry in ...

1994-12-31

491

Pressure drop and heat transfer characteristics of boiling water in sub-hundred micron channel  

Energy Technology Data Exchange (ETDEWEB)

The current work focuses on the pressure drop, heat transfer and stability in two phase flow in microchannels with hydraulic diameter of less than one hundred microns. Experiments were conducted in smooth microchannels of hydraulic diameter of 45, 65 {mu}m, and a rough microchannel of hydraulic diameter of 70 {mu}m, with deionised water as the working fluid. The local saturation pressure and temperature vary substantially over the length of the channel. In order to correctly predict the local saturation temperature and subsequently the heat transfer characteristics, numerical techniques have been used in conjunction with the conventional two phase pressure drop models. The Lockhart-Martinelli (liquid-laminar, vapour-laminar) model is found to predict the two phase pressure drop data within 20%. The instability in two phase flow is quantified; it is found that microchannels of smaller hydraulic diameter have lesser ...

2009-09-15

492

A numerical investigation on the influence of liquid properties and interfacial heat transfer during microdroplet deposition onto a glass substrate  

CERN Document Server

This work investigates the impingement of a liquid microdroplet onto a glass substrate at different temperatures. A finite-element model is applied to simulate the transient fluid dynamics and heat transfer during the process. Results for impingement under both isothermal and non-isothermal conditions are presented for four liquids: isopropanol, water, dielectric fluid (FC-72) and eutectic tin-lead solder (63Sn-37Pb). The objective of the work is to select liquids for a combined numerical and experimental study involving a high resolution, laser-based interfacial temperature measurement to measure interfacial heat transfer during microdroplet deposition. Applications include spray cooling, micro-manufacturing and coating processes, and electronics packaging. The initial droplet diameter and impact velocity are 80 {\\mu}m and 5 m/s, respectively. For isothermal impact, our simulations with water and ...

2010-01-01

493

Laboratory Evaluation of an Electrochemical Noise System for Detection of Localized and General Corrosion of Natural Gas Transmission Pipelines  

Energy Technology Data Exchange (ETDEWEB)

Gas transmission pipelines are susceptible to both internal (gas side) and external (soil side) corrosion attack. Internal corrosion is caused by the presence of salt laden moisture, CO{sub 2}, H{sub 2}S, and perhaps O{sub 2} in the natural gas. Internal corrosion usually manifests itself as general corrosion. However, the presence of chlorides in entrained water also can lead to pitting corrosion damage. The electrochemical noise technique can differentiate general from localized corrosion and provide estimates of corrosion rates without external perturbation of the corroding system. It is increasingly being applied to field and industrial installations for in situ corrosion monitoring. It has been used here to determine its suitability for monitoring internal and external corrosion damage on gas transmission pipelines. Corrosion measurements were made in three types of environments: (1) aqueous solutions typical of those found within gas pipelines in equilibrium ...

2003-03-16

494

Identification method for gas-liquid two-phase flow regime based on singular value decomposition and least square support vector machine  

International Nuclear Information System (INIS)

Aiming at the non-stationary characteristics of differential pressure fluctuation signals of gas-liquid two-phase flow, and the slow convergence of learning and liability of dropping into local minima for BP neural networks, flow regime identification method based on Singular Value Decomposition (SVD) and Least Square Support Vector Machine (LS-SVM) is presented. First of all, the Empirical Mode Decomposition (EMD) method is used to decompose the differential pressure fluctuation signals of gas-liquid two-phase flow into a number of stationary Intrinsic Mode Functions (IMFs) components from which the initial feature vector matrix is formed. By applying the singular vale decomposition technique to the initial feature vector matrixes, the singular values are obtained. Finally, the singular values serve as the flow regime characteristic vector to be LS-SVM classifier and flow regimes are identified by the output of the classifier. The identification result of four typical flow regimes of ...

2007-12-01

495

Horizontal slug flow properties captured by intermittent slug tracking model  

Energy Technology Data Exchange (ETDEWEB)

The oil production is largely transported in pipelines operating in two-phase flow regime. The predominant flow pattern is the slug flow, which is characterized by intermittent succession of liquid slugs followed by long gas bubbles. This paper addresses specifically to the capture of the intermittently feature of slug flows using a compressible slug tracking model. The intermittency rules the bubble to bubble interactions, defines the bubble coalescence rate, changes the size of the bubbles, alters the pressure drop among other flow properties. The inlet sizes and velocities of the bubbles and slugs are estimated based on experimentally determined distributions characterized by its mean value and standard deviation. The inlet intermittency, transmitted through the inlet boundary condition, results in a better match of the fluctuating flow properties along the pipe. The simulations are carried out with air-water flow and the results present ...

2008-07-01

496

EMFs run aground  

International Nuclear Information System (INIS)

Presently no one knows whether electromagnetic fields (EMFs) play a role in human cancer or other ailments, though epidemiological studies over the years have suggested that possibility. A study by the Electric Power Research Institute attempted to quantify everything it could about the magnetic environment of a home, identifying not only major sources of magnetic fields, but also their frequencies, strengths, and how they fall off with distance. Sources of a homes magnetic environment include appliances, overhead powerlines, and grounding connections to metallic water pipes. Fields will vary over time, depending on how much current is passing through the electrically conductive sources. Additional contributors to a home's magnetic background may include unusual wiring in the walls, underground power lines, and near-by high voltage transmission lines. This paper summarizes the study results, indicating weak, persistant EMFs may dominate, but ...

1993-08-01

497

Corrosion in drilling and well stimulation  

Energy Technology Data Exchange (ETDEWEB)

Corrosion in drilling and well stimulation is described in relation to acid corrosion inhibition, acid inhibitors, acetylenic inhibitors, synergistic blends, metallurgy, wellbore tubulars, coiled tubing, and high alloy tubular materials. Acidizing is a procedure for stimulating oil and gas wells. Factors that have an important influence on the reaction rate and the way in which acid reacts with rock include temperature, acid concentration, acid volume, injection velocity, acid viscosity, and fluid loss properties of the formation. The cost of drill pipe failures are $1 per fot of hole drilled, which is a significant fraction of the drilling cost. Steps in a test procedure are listed, as well as factors which determine the extent of acid corrosion in a given situation including acid type and strength, metal type, temperature, contact time; pressure, and volume/surface area ratio. Underbalanced drilling is a method for completing oil and gas wells that minimizes the ...

1999-07-01

498

Core and containment safety analyses for the reduction of boron concentration in the boron injection tank of Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

The design boron concentration of the Boron Injection Tank (BIT) in Daya Bay Nuclear Power Station is 21000 #mu#g/g. The BIT should operate under high temperature to avoid boron crystallization, causing higher evaporation, frequent water makeup, higher deposition and pipe blockage to decrease the operability of the safety injection system. The author proposes to decrease the boron concentration in BIT from 21000 #mu#g/g to 7000 #mu#g/g to solve the existing problem. The safety analyses (core DNBR and containment response) are conducted and other impacts are evaluated for the BIT reduction. The analysis results show that the core DNBR meets the safety criterion and the containment pressure is within the design value for the steam line rupture accident after the BIT reduction. The feasibility study report of Daya bay BIT reduction has been approved by NNSA. The site implementation of BIT reduction has been finished successfully

1999-12-01

499

An Experimental study on a Method of Computing Minimum flow rate  

International Nuclear Information System (INIS)

Many pump reliability problems in the Nuclear Power Plants (NPPs) are being attributed to the operation of the pump at flow rates well below its best efficiency point(BEP). Generally, the manufacturer and the user try to avert such problems by specifying a minimum flow, below which the pump should not be operated. Pump minimum flow usually involves two considerations. The first consideration is normally termed the 'thermal minimum flow', which is that flow required to prevent the fluid inside the pump from reaching saturation conditions. The other consideration is often referred to as 'mechanical minimum flow', which is that flow required to prevent mechanical damage. However, the criteria for specifying such a minimum flow are not clearly understood by all parties concerned. Also various factor and information for computing minimum flow are not easily available as considering for the pump manufacturer' proprietary. The objective of this study is to obtain experimental data for ...

2009-10-01

500

A method for the optimal design of networks of drinking water distribution; Un metodo para el diseno optimo de redes de distribucion de agua potable  

Energy Technology Data Exchange (ETDEWEB)

A method to select, among several commercial diameter options, the most economic combination of pipeline networks is presented. These networks comply with the discharge conditions in the pipes and pressure in the knots. It is applied a static method for the hydraulics analysis of the Engineering Institute of the Universidad Nacional Autonoma de Mexico (UNAM) and an optimization technique to reduce the number of calculations. [Spanish] Se presenta un metodo para seleccionar, de entre varias opciones de diametros comerciales, la combinacion que forma la red de tuberias mas economica que satisface las condiciones de gasto en los tubos y de presion en los nudos de la misma. Para el analisis hidraulico se emplea un metodo estatico del Instituto de Ingenieria de la Universidad Nacional Autonoma de Mexico (UNAM) y se aplica una tecnica de optimacion para reducir el numero de calculos y alcanzar la solucion.

1998-12-01