WorldWideScience
1

Steady-state thermal and hydraulic calculation of steam generator considering heat transfer tube lengths  

Energy Technology Data Exchange (ETDEWEB)

The effect of heat transfer is described from heat exchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heat exchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heat exchange tubes neqlecting the changes of physical properties of water along the heat exchange tubes, will yield sufficiently accurate results.

1982-10-01

2

Steady-state thermal and hydraulic calculation of steam generator considering heat transfer tube lengths  

International Nuclear Information System (INIS)

The effect of heat transfer is described from heat exchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heat exchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heat exchange tubes neqlecting the changes of physical properties of water along the heat exchange tubes, will yield sufficiently accurate results. (author).

1982-01-01

3

Air-side performance of a parallel-flow parallel-fin (PF{sup 2}) heat exchanger in sequential frosting  

Energy Technology Data Exchange (ETDEWEB)

The thermal-hydraulic performance in periodic frosting conditions is experimentally studied for the parallel-flow parallel-fin heat exchanger, henceforth referred to as a PF{sup 2} heat exchanger, a new style of heat exchanger that uses louvered bent fins on flat tubes to enhance water drainage when the flat tubes are horizontal. Typically, it takes a few frosting/defrosting cycles to come to repeatable conditions. The criterion for the initiation of defrost and a sufficiently long defrost period are determined for the test PF{sup 2} heat exchanger and test condition. The effects of blower operation on the pressure drop, frost accumulation, water retention, and capacity in time are compared under the conditions of 15 sequential frosting cycles. Pressure drop across the ...

2010-09-15

4

Thermal gradient humidification-dehumidification desalination system  

Energy Technology Data Exchange (ETDEWEB)

A solar energy desalination process utilizing solar radiation directly for the evaporation of salt water is described. Ambient air takes on water vapor as the air passes through an evaporative medium. It is then directed between a saline water-covered, solar absorbing surface and a solar collecting housing. The resulting heated and moisture-saturated air is cooled in a heat exchange means where condensation of fresh water occurs. Simultaneously, cool salt water is utilized as the cooling water in the heat exchange means, and takes on the heat of condensation given up by the condensing vapor. The heated salt water from the heat exchange means is partially ...

1982-12-14

5

Heat rejection system  

Energy Technology Data Exchange (ETDEWEB)

A cooling system for rejecting waste heat consists of a cooling tower incorporating a plurality of coolant tubes provided with cooling fins and each having a plurality of cooling channels therein, means for directing a heat exchange fluid from the power plant through less than the total number of cooling channels to cool the heat exchange fluid under normal ambient temperature conditions, means for directing water through the remaining cooling channels whenever the ambient temperature rises above the temperature at which dry cooling of the heat exchange fluid is sufficient and means for cooling the water. 5 figs.

1980-01-22

6

Isolation condenser passive cooling of a nuclear reactor containment  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a nuclear system comprising a containment airspace in which a nuclear reactor pressure vessel is disposed there being a reactor core within the pressure vessel. It comprises a heat exchanger elevated a distance above the pressure vessel; a pool of water surrounding the heat exchanger; means for venting the pool of water to an environment outside the containment; a heat exchanger entry conduit within the containment, the entry conduit having an open lower end communicating with the containment space, and an upper end connected to the heat exchanger, water-containing heated fluid present in the containment airspace incident a pressure vessel loss of coolant event entering and flowing through the entry conduit into the ...

1991-10-22

7

Thermogalvanic effects on the pitting corrosion of water-cooled heat exchangers  

Energy Technology Data Exchange (ETDEWEB)

Thermogalvanic corrosion of St3 steel in a temperature range from 25 to 50{degrees}C with a 3.84{degrees}C/cm gradient was studied in a neutral media flow. It is shown that the thermogalvanic effect on the pitting corrosion of water-cooled heat exchangers is decisive but dual. Depending on the composition of the cooling medium, thermogalvanic corrosion may either enhance (0.5 M NaCl) or inhibit (tap water) pitting corrosion.

1995-05-01

8

Recovery of Water from Boiler Flue Gas  

Energy Technology Data Exchange (ETDEWEB)

This project dealt with use of condensing heat exchangers to recover water vapor from flue gas at coal-fired power plants. Pilot-scale heat transfer tests were performed to determine the relationship between flue gas moisture concentration, heat exchanger design and operating conditions, and water vapor condensation rate. The tests also determined the extent to which the condensation processes for water and acid vapors in flue gas can be made to occur separately in different heat transfer sections. The results showed flue gas water vapor condensed in the low temperature region of the heat exchanger system, with water capture efficiencies depending strongly on flue gas moisture content, cooling ...

2008-09-30

9

Telephone exchange Feutersoey - first pilot plant of the PTT with solar collectors  

Energy Technology Data Exchange (ETDEWEB)

In the course of this year six local exchange offices with alternative heating and hot water plants were started up in Switzerland. They are all of the same building type, designed for not more than 1000 telephone subscribers and for the same architectural conditions. However, the buildings are situated in different areas of the country and are thus subject to different environmental conditions. Solar collectors supplemented by electricity boilers are fitted to two of these objects. Heat pumps are operated in two other exchange offices while the last two are equipped with electric heating devices. For purposes of comparison two new test plants of the same size with oil heating devices are set up.

1981-01-01

10

Safety considerations of active process water system shutdown for TAPP - 3 and 4  

International Nuclear Information System (INIS)

Active Process Water (APW) System, provided as unitized closed loop system in Tarapur Atomic Power Project Units-3 and 4, serves to remove heat from various heat exchangers. One of the important loads served by APW system is shutdown cooling heat exchangers and if APW shutdown is taken then reactor cannot be maintained in cold shutdown condition. It is estimated that after 7 days of reactor shutdown, if about 20% of the normal cooling flow to shutdown cooling heat exchangers is provided then along with keeping PHT in cold shutdown state, reactor components, moderator, end shield water, calandria vault water and calandria vault concrete temperature can be maintained within technical specification limits for extended duration. (author)

2005-12-01

11

Thermal energy storage system with stearic acid as phase change material  

Energy Technology Data Exchange (ETDEWEB)

A simple tube-in-tube heat exchanger system for thermal energy storage employing stearic acid as PCM has been investigated. The performance and heat transfer characteristics of such a system were studied. Phase transition temperature range and times were measured and the speed of the phase transition front was computed. The melting front was found to move in the radial direction inward as well as in the axial direction from the top toward the bottom of the phase change material PCM tube. The speed of the melting front is enhanced by a convection heat transfer mechanism in the melted PCM. The heat transfer rate and, consequently, phase transition time can be altered by changing the water inlet temperature to the heat exchanger. In addition, a faster phase transition is realized by placing the heat ...

1994-10-01

12

Application of a finite element method to leak before break (LBB) of a heat exchanger  

International Nuclear Information System (INIS)

The leak before break (LBB) concept is difficult to apply to a structure with a thin tube that is immersed in a water environment. A heat exchanger in a nuclear power plant is such a structure. The present paper addresses an application of the LBB concept to a heat exchanger in a nuclear power plant. The minimum leaked coolant amount containing the radioactive material which can activate the radiation detector device installed near the heat exchanger is assumed. The postulated initial flaw size that cannot grow to the critical flaw size within the time period to activate the radiation detector is justified. In this case, the radiation detector can activate the warning signal caused by coolant leakage from initially postulated flaws of the heat exchanger. The nuclear plant can safely shutdown when ...

2003-08-17

13

Energy saving self-powered industrial dehumidifier  

Energy Technology Data Exchange (ETDEWEB)

An energy saving self-powered industrial dehumidifier for use in a building having a tap water conduit leading from a source of supply to utilization points is described comprising: a dehumidifying apparatus positioned in a stream of air to be dehumidified in the building. The dehumidifying apparatus comprising conduit means for diverting at least a portion of a relatively continuously moving stream of tap water from the tap water conduit through a heat exchanger positioned in a stream of air and returning the diverted portion to the tap water stream upstream of the utilization points. Water vapor in the stream of air will condense onto the heat exchanger when the tap water has a temperature below a dew point temperature of the air stream, thereby dehumidifying the air stream.

1988-07-26

15

Improvement of the PGV-1000 steam generator in-vessel components  

International Nuclear Information System (INIS)

Results of calculational investigations into circulation of water and steam-and-water mixture in the PGV-1000 steam generator heat exchanger bundle used at NPPs with the WWER-1000 reactors, are considered. Model of water circulation in horizontal steam generator with submerged heating surface under conditions of steam generation irregularity along the heat transfer tubes is made. On the basis of the obtained data the assumption is made about water essential overflows from the hot collector zone into the cold one. Overflow rate over the upper line of the heat transfer tubes may constitute 0.7 m/s. The conclusion is made about the necessity to set up the vertical barrier which divides hot and cold sections of heat transfer tubes and helps to avoid water ...

1988-01-01

16

Study of the Energy Efficiency of the Melting Unit at the Rockwool Company Mineral Wool Process in Skoevde, Sweden.  

Science.gov (United States)

The melting unit, consisting of a water-cooled cupola furnace, afterburner, heat exchanger, air preheater, consumes most of the supplied energy in the rockwool process. The report maps the energy flows and defines factors of merit according to thermodynam...

1979-01-01

17

Heat Transfer Augmentation in a Compact Heat Exchange Pedestal Array.  

Science.gov (United States)

A compact heat exchanger pedestal array for augmenting heat transfer in a machine is disclosed. The compact heat exchanger pedestal array includes a wall having first and second surfaces. The first surface faces a heated flow path and the second surface p...

2004-01-01

18

AquaMagna Water Conditioner and Descaler  

Wastenet

...AquaMagna Water Conditioner and Descaler OCETA Environmental Technology & Business Profiles AQUAMAGNA WATER CONDITIONER AND DESCALER CAT. #03-018 CONTACT: Magna-Tek ...removal high-strength ceramic magnet no energy input The AquaMagna Water Conditioner and Descaler is a non-chemical method of water treatment. The technology uses ... Figure 1: The AquaMagna Water Conditioner and Descaler PROCESS/ PRODUCT APPLICATION: hard water domestic water process water reverse osmosis heat exchangers cooling ... For once-through or recirculating heating or cooling equipment, the AquaMagna descaler improves thermal efficiencies and reduces downtime. Figure 2 illustrates a cross-section ...

19

FY1998 research report on the basic research on geothermal district heating in Kamchatka, Russia; 1998 nendo Roshia Renpo Kamchatka shu ni okeru chinetsu riyo ni yoru chiiki danbo ni kansuru kiso chosa hokokusho  

Energy Technology Data Exchange (ETDEWEB)

Petropavlovsk-Kamchatky (P-K) city in Kamchatka, Russia is operating hot-water district heating using heavy oil boilers and waste hot water of thermal power plants as heat sources. Feasibility study was made on district heating using natural geothermal hot water and/or geothermal heat pump systems as heat sources of hot water supply for reduction of greenhouse effect gas emission. Among 3 areas including geothermal hot water, use of hot water in K area was impossible because of lower temperature and less spring water. Use of hot water in P and UP areas was impossible as primary hot water because of temperature drop to 64 degrees C during hot water supply toward P-K city. The ...

1999-05-01

20

Heat transfer problems in high temperature heat exchangers  

International Nuclear Information System (INIS)

This paper deals with construction types of high temperature heat exchangers, their circulation loops and temperature differences. Most attention is given to gas dynamics, convective heat transfer, convection and radiant heat transfer interaction in high temperature heat exchangers. The ways of heat transfer augmentation and efficient heat exchanger construction are discussed.

1986-01-01

21

Heat Transfer Characteristics of Tubular Thermal Reactor  

International Nuclear Information System (INIS)

Heat transfer augmentation based on the process intensification concept in heat exchangers and thermal reactors has received much attention in recent years, mainly due to energy efficiency and environmental considerations. The concept consists of the development of novel apparatuses and techniques that, compared to those commonly used today, are expected to bring dramatic improvements in manufacturing and processing, substantially decreasing equipment size, energy consumption, and ultimately resulting in cheaper, sustainable technologies. The objective of this paper was to investigate the heat transfer characteristics of tubular thermal reactor using static mixing technology. Glycerin and water were used as the test fluids and water was used as the heating source. The results for heat transfer rate were strongly ...

22

Surface wettability effect on an indirect evaporative cooling system  

Energy Technology Data Exchange (ETDEWEB)

Indirect evaporative air coolers that use air-to-air plate-type heat exchangers show good promise (compared with compression air-conditioning systems) of extending the energy savings from arid, low-humidity areas to more widespread climatic conditions. However, no systematic experiment had been done concerning the effect of the wettability of aluminum plates on the effectiveness of the indirect evaporative cooling system. In this study, a testing apparatus was built where only one secondary channel and two primary channels were used so that different surfaces could be easily tested to determine the system`s effectiveness and the heat transfer coefficient. The advantage of this experimental apparatus is that plates of the heat exchanger can be easily changed in the test section instead of fabricating a complete heat exchanger for each test. A ...

1996-11-01

23

Determination of water level profile along heat exchange tubes of horizontal steam generator PGV 1000 M  

International Nuclear Information System (INIS)

A mathematical model is described for determining the level profile along the length of heat exchange tubes in a horizontal steam generator, and for determining the conditions in the steam cushion under the perforated sheet. The water level area is divided in the model into 36 partial elements; for analysis of the conditions under the level, the steam-water space is divided into four areas. The results of the calculations were compared with measurement results for the steam generator rated values. Very good agreement was found. The results show that, among others, the supply water distribution very much affects the conditions in the area of the steam cushion and of the bubble vacuum. Also, the average steam load of the inner bundle tubes is significantly higher than that of the outer bundles. It was also shown that permanent steam generator operation with exposed top tube rows may ...

24

Finalisation of design provision for active process water system shut down at TAPP-3 and 4  

International Nuclear Information System (INIS)

Active Process Water (APW) system is provided as a unitized system in TAPP-3 and 4. Maintenance on APW system requires shutdown of this system. As shut down heat exchangers are fed by APW system; during APW system shutdown cold shutdown state cannot be maintained. Therefore safety analysis is done to optimize the duration of reactor shutdown (which means low decay heat) after which APW shutdown can be taken with minimum water supply to the shutdown heat exchangers. Based on this analysis, it is proposed in technical specification that APW system shutdown can be taken after 7 days of reactor shutdown with shutdown heat exchangers supplied with about 20 % of normal APW flow. With this configuration, PHTS, moderator, end shield, calandria vault water temperature can be maintained ...

2006-11-13

25

Comparative performance of two types of evacuated tube solar collectors in a residential heating and cooling system. The progress report  

Science.gov (United States)

Two types of evacuated tube solar collectors have been operated in space heating, cooling and domestic hot water heating systems in Colorado State University Solar House I. An experimental collector from Corning Glass Works supplied heat to the system from January 1977 through February 1978, and an experimental collector from Philips Research Laboratory, Aachen, which is currently in use, has been operating since August 1978. A flat absorber plate inside a single-walled glass tube is used in the Corning design, whereas heat is conducted through a single glass wall to an external heat exchanger plate in the Philips collector. In comparison with conventional flat-plate collectors, both types show reduced heat losses and improved efficiency. For space heating and hot water supply in ...

1979-01-01

26

GRI's Gas Appliance Technology Center Activities at Battelle. Final report, 1986-1992  

Science.gov (United States)

The Gas Research Institute established the Gas Appliance Technology Center (GATC) in 1982 to develop improved gas appliances. Between 1986 and 1992, the scope of GATC activities at Battelle included technology transfer and overall industry support, residential appliances, commercial appliances, and residential space conditioning. The following tasks are representative of the GATC activities described in the report; gas burner technology, appliance venting, emissions, water heating, range/oven technology, self-powered appliances, commercial cooktop burners, reconstituting ovens, appliance reliability improvement, combination space-heating/water-heating systems, condensing heat exchangers, corrosion testing, and space heating technology. The report includes references to available sources for further reading.

1993-08-01

27

Competition advantage by utilizing the gross calorific value-high potential for the local heat supply; Wettbewerbsvorsprung durch Brennwertnutzung. Hohes Potential bei der Nahwaermeversorgung  

Energy Technology Data Exchange (ETDEWEB)

The gross calorific value (H{sub o}) is the amount of heat which is generated by total combustion of a type of fuel. It also includes that part of heat which is generated by steam from evaporated water contained in heating gas. In conventional heating boilers, this heat portion is not being utilized at all. To utilize the gross calorific value, it is necessary to extract from the exhaust gas the evaporation heat bound in steam and to return this to the heating system. This means that the exhaust gas has to be chilled by the return water of the heating system and condensed in suitable heat exchangers to well below the dew point. (orig.) [Deutsch] Waermelieferanten im Bereich der Nahwaermeversorgung koennen durch die Anwendung verfuegbarer ...

1999-01-01

28

Thermal energy storage system using stearic acid as a phase change material  

Energy Technology Data Exchange (ETDEWEB)

The thermal performance and phase change stability of stearic acid as a latent heat energy storage material has been studied experimentally. The thermal performance and heat transfer characteristics of the stearic acid were tested and compared with other studies given in the literature. In the present study, parameters such as transition times, temperature range and propagation of the solid-liquid interface as well as the effect of heat flow rate on the phase change stability of stearic acid as a phase change material (PCM) were studied. The experimental results showed that the melting stability of the PCM is better in the radial direction than in the axial direction. The variation in the melting and solidification parameters of the PCM with the change of inlet water temperature is also studied. We observed that while the heat exchanger tube is in the horizontal ...

2001-07-01

29

Horizontal ground coupled heat pump: Thermal-economic modeling and optimization  

Energy Technology Data Exchange (ETDEWEB)

The modeling and optimizing processes of a Ground Coupled Heat Pump (GCHP) with closed Horizontal Ground Heat eXchanger (HGHX) are presented in this paper. After thermal modeling of GCHP including HGHX, the optimum design parameters of the system were estimated by minimizing a defined objective function (total of investment and operation costs) subject to a list of constraints. This procedure was performed applying Genetic Algorithm technique. For given heating/cooling loads and various climatic conditions, the optimum values of saturated temperature/pressure of condenser and evaporator as well as inlet and outlet temperatures of the water source in cooling and heating modes were predicted. Then, for our case study, the design parameters as well as the configuration of HGHX were obtained. Furthermore, the sensitivity analysis of change in the total annual cost ...

2010-12-15

30

Integrated numerical modeling of surface-subsurface-coupled, 2-phase fluid/heat flow in limnological system 1. New type of modeling and experimental study; Shizen suirikei no ryutai{center_dot}netsu ido togo moderingu no kokoromi 1. Ryutai{center_dot}netsu ido no atarashii teishikika to jikkenteki kento  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the comprehensive modeling method of fluid and heat flows in the hydrological system. Based upon the concept that the hydrological system is composed of the air-water 2-phase fluids, and the rock phase, various natural processes are modeled including surface/subsurface 2-phase mass transfer, heat exchanges between fluid phases, between fluid and solid phases, and sensible/latent heat exchanges on the ground surface. A field-oriented numerical simulator is developed, in which a set of governing equations is solved for different variables on the surface and in subsurface regions, respectively. Results of an experimental study are presented, in which transient formulation of heat exchange between fluid/solid phases is examined through matching of the observation and calculated performances. (author)

1999-08-31

31

Integrated numerical modeling of surface-subsurface-coupled, 2-phase fluid/heat flow in limnological system 1. New type of modeling and experimental study. Shizen suirikei no ryutai[center dot]netsu ido togo moderingu no kokoromi 1. Ryutai[center dot]netsu ido no atarashii teishikika to jikkenteki kento  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the comprehensive modeling method of fluid and heat flows in the hydrological system. Based upon the concept that the hydrological system is composed of the air-water 2-phase fluids, and the rock phase, various natural processes are modeled including surface/subsurface 2-phase mass transfer, heat exchanges between fluid phases, between fluid and solid phases, and sensible/latent heat exchanges on the ground surface. A field-oriented numerical simulator is developed, in which a set of governing equations is solved for different variables on the surface and in subsurface regions, respectively. Results of an experimental study are presented, in which transient formulation of heat exchange between fluid/solid phases is examined through matching of the observation and calculated performances. (author)

1999-08-31

32

Study on the application of a geothermal heat pump; Etude sur l`application d`une pompe a chaleur geothermique  

Energy Technology Data Exchange (ETDEWEB)

The heating system of the `Centre integre de mecanique industrielle de la Chaudiere`, in Saint-Georges, Quebec, is based on a solar wall and a geothermal heat pump with a glycol/water mixture circulating in 44 wells that are 100 m deep. With installation costs below $25 per sq.m, more than 85 per cent of the heating needs of the 9500 sq.m centre were supplied by geothermal power. The geothermal heat pump is composed of a well field and two 211-kW cooling units, each equipped with four coiled compressors. In winter, heat is pumped from the earth and in summer, a heat exchanger with control valves allows to heat to be dumped back into the earth. The monitoring and simulation of the system proved its efficiency, considering the climatic conditions in Quebec. The annual consumption of geothermal ...

1996-12-01

33

Pitting corrosion of copper and copper alloys. (Latest citations from the Metals Abstracts alloys index database). Published Search  

Energy Technology Data Exchange (ETDEWEB)

The bibliography contains citations concerning the pitting corrosion of copper and copper alloys, in different media, with some references to methods for protecting against such corrosion. Included are factors contributing to the onset of pitting corrosion. Emphasis is placed on exposure to water, especially in tubing for heat exchangers and water conduits. Many of the citations present studies on exposure to sea water. Some references pertain to the detection of pitting corrosion in installations and the evaluation of the degree of pitting present. (Contains 250 citations and includes a subject term index and title list.)

1993-09-01

34

Fiscal 2000 project of inviting proposals for international joint research - invitation for international proposal (Energy conservation No.2). Achievement report on international joint study on popularization promotion of geothermal heat pump-assisted environmentally compatible heating system for Changchun City, China; 2000 nendo kokusai kyodo kenkyu teian kobo jigyo - kokusai teian kobo (Shoe No.2). Chinetsu heat pump ni yoru Chugoku Changchun shi kankyo tekigogata danbo system no fukyu sokushin ni kansuru kokusai kyodo kenkyu seika hokokusho  

Energy Technology Data Exchange (ETDEWEB)

A geothermal heat pump-assisted heating system is introduced into Changchun City and a survey is conducted to determine if the system may be popularized in this extremely cold region located in the northeastern part of China. In concrete terms, the hot water that circulates through the office building of Changchun Ground Heat Development Co., Ltd., is switched to hot water prepared by a geothermal heat pump. The test continued from December 2000 to March 2001. It is then concluded that heating by geothermal heat pumps will be fully serviceable to Changchun City. Implemented are (1) the shift from the coal fired boiler system to a geothermal heat pump system comprising 16 subterranean heat exchangers for the heating of the office building ...

2001-03-01

35

A review of heat exchanger tube bundle vibrations in two-phase cross-flow  

International Nuclear Information System (INIS)

Flow-induced vibration is an important concern to the designers of heat exchangers subjected to high flows of gases or liquids. Two-phase cross-flow occurs in industrial heat exchangers, such as nuclear steam generators, condensers, and boilers, etc. Under certain flow regimes and fluid velocities, the fluid forces result in tube vibration and damage due to fretting and fatigue. Prediction of these forces requires an understanding of the flow regimes found in heat exchanger tube bundles. Excessive vibrations under normal operating conditions can lead to tube failure. Relatively little information exists on two-phase vibration. This is not surprising as single-phase flow induced vibration; a simpler topic is not yet fully understood. Vibration in two-phase is much more complex because it depends upon two-phase flow regime, i.e. characteristics of two-phase ...

2004-05-01

36

Post-CHF heat transfer with water and refrigerants  

Energy Technology Data Exchange (ETDEWEB)

Heat transfer experiments were performed in the post-CHF two-phase flow regime in a vertical tube. The tube inside diameter was 7.75 mm, and the boiling fluid was R-113. The experiments were performed at steady state by means of liquid heating of the test tube. Wall superheats were maintained below 70 C for heat exchanger/steam generator application. The mass flux range of the data was 379-816 kg m{sup -2} s{sup -1}. The use of R-113 significantly extended the property range of the existing low wall-superheat data base. Experimental data are presented in tabular as well as graphical form, and the results were used with low wall-superheat data from other fluids to add generality to a predictive heat transfer correlation. (orig.)

1996-06-01

37

Numerical simulation of fluid flow and heat transfer in a concentric tube heat exchanger  

International Nuclear Information System (INIS)

In this paper, numerical simulation of a concentric tube heat exchanger is presented to determine the convective heat transfer coefficient and friction factor in a smooth tube. Increasing the convective heat transfer coefficient can increase heat transfer rate in a concentric tube heat exchanger from a given tubular surface area. This can be achieved by using heat transfer augmentation devices. This work constitutes the initial phase of the numerical simulation of heat transfer from tubes employing augmentation devices, such as twisted tapes, wire-coil inserts, for heat transfer enhancement. A computational fluid dynamics (CFD) simulation tool was developed with CFX software and the results obtained from the simulations are validated with the empirical correlations for a smooth ...

2003-05-28

38

SPECIAL EDDY CURRENT PROBES FOR HEAT ...  

Science.gov (United States)

... Accession Number : ADD326926. Title : SPECIAL EDDY CURRENT PROBES FOR HEAT EXCHANGER INSPECTION. Corporate Author : ...

1986-11-01

39

Indirect heating of natural gas using vapor chambers; Aquecimento indireto de gas natural com uso de camaras de vapor  

Energy Technology Data Exchange (ETDEWEB)

Operation safety and reliability are major guidelines in the design of city-gate units. Conventional natural gas heaters operate by a indirect mechanism, where liquid water is used to transfer heat by natural convection between the combustion chamber and the natural gas coil. In this work, the concept of vapor chamber is evaluated as an indirect gas heater. In a vapor chamber, liquid water is in contact with the heat source, and vaporizes. The vapor condenses in contact with the heat sink. A reduced scale model was built and tested in order to compare these two heating concepts where the combustion chamber was replaced by electrical cartridge heaters. This engineering model can operate either as a conventional heater or as a vapor chamber. The comparison between the concepts was done by inducing a controlled power to the cartridges and by measuring the resulting ...

2005-07-01

40

Heat transfer performance of a fin with two fences and tube heat exchanger. Study in the low Reynolds number range; Fence wo fusetsushita fin tsuki kan netsu kokanki unit no ryudo dennetsu sogo tokusei. Tei Reynolds suiki ni okeru kosatsu  

Energy Technology Data Exchange (ETDEWEB)

A three-dimensional steady numerical computation was made for a component model of fin and tube type of compact heat exchangers situated in a uniform flow. In this study, in order to find a clue to design high-efficient heat exchangers, numerical computation was made in the case where two fences are attached on the plate fin surface and their geometrical effects such as their locations, their heights and their attack angles on flow and heat transfer characteristics were investigated especially in the low Reynolds number range. The effect of a hole, open in the plate fin behind the fence, on heat transfer and flow structures was also examined. This hole simulates the hole of the plate fin to be produced in practical application, when a fence is produced by punching from the original plain fin plate. Two fences with holes were found to show several important ...

2000-07-25

41

Growth model and on-line measurement of pitting corrosion on carbon steel  

Energy Technology Data Exchange (ETDEWEB)

A growth model of pitting corrosion of carbon steel in cooling water systems was developed on microscopic observations of pits and electrochemical studies. Results of pitting corrosion measurements in laboratory and field conditions with the model, using a newly developed electrochemical device, are discussed. For an actual heat exchanger up to a year operation, the values of pitting depth estimated were in good agreement with the measured values.

1996-12-01

42

Air-side flow and heat transfer in compact heat exchangers: A discussion of enhancement mechanisms  

Energy Technology Data Exchange (ETDEWEB)

The behavior of air flows in complex heat exchanger passages is reviewed with a focus on the heat transfer effects of boundary-layer development, turbulence, spanwise and streamwise vortices, and wake management. Each of these flow features is discussed for the plain, wavy, and interrupted passages found in contemporary compact heat exchanger designs. Results from the literature are used to help explain the role of these mechanisms in heat transfer enhancement strategies.

1998-10-01

44

Technical-economic aspects of the utilization of geothermal waters  

International Nuclear Information System (INIS)

A brief description is given of the physico-chemical parameters characterized a hot water geothermal reservoir and of its exploitation by means of single or coupled (doublet) wells. The technical aspects of geothermal heat to the users is then discussed, beginning with corrosion of materials caused by seven main agents: oxygen, hydrogen sulphide, carbon dioxide, ammonia, hydrogen, sulphates and chlorides. A brief mention is made of scaling due to calcium carbonate, silica and calcium sulphates. The basic components of a geothermal plant for non-electric uses are then discussed: production pumps, surface pipelines, heat exchangers, heat pumps and reinjection pumps. The advantages and disadvantages of the different equipment and materials used in the geothermal sector are also presented. A list is also given of the criteria used in the energy and economic balance of a geothermal ...

45

Study of solution for issues of an optimum operating plan in heat storing system; Chikunetsu system ni okeru saiteki un`yo keikaku mondai no kaiho ni taisuru ichikosatsu  

Energy Technology Data Exchange (ETDEWEB)

An approximate solution was proposed in which a sensitivity analysis by the storage and release of heat was performed for the subject issues and in which an operating method was thereby determined for the equipment constituting the system by means of a linear programming. Accordingly, a heat storage type energy supply system for a district cooling and heating was taken up as a concrete object to be examined. This system consisted of a gas turbine generator, initial power receiving equipment, gas boiler, electric heat pump for ice heat storage, cooling tower, heat exchanger, steam absorbing refrigerating machine, ice heat storage tank, cold and warm water heat storage tank, etc. As a result of comparison between the proposed method and the resolving method, the former showed -0.92 ...

1996-02-01

46

Control of anodic passivation systems  

Energy Technology Data Exchange (ETDEWEB)

A method is described of controlling an anodic protection system in a heat exchanger comprising: (a) installing at least one cathode within the heat exchanger, at least one cathode being aligned with the longitudinal axis of the heat exchanger and extending substantially along the length of the heat exchanger; (b) installing a first reference electrode within and at one end of the heat exchanger, the first reference electrode having a first controller having a set point for control and a power supply having an output creating an electrical potential between at least one cathode and the heat exchanger; (c) measuring the electrical potential of the heat exchanger with the first reference electrode; ...

1987-08-25

47

Pitting corrosion of copper and copper alloys. (Latest citations from the EI Compendex*plus database). Published Search  

Energy Technology Data Exchange (ETDEWEB)

The bibliography contains citations concerning the pitting corrosion of copper and copper alloys by different media, with some references to methods that protect against such corrosion. Included are factors contributing to the onset of pitting corrosion. Emphasis is placed on exposure to water, especially in heat exchanger tubing and water conduits. Studies are included which examine corrosion in metals containing small amonts of copper where corrosion is attributable to changes in alloying. (Contains a minimum of 158 citations and includes a subject term index and title list.)

1994-04-01

48

Daya Bay gets underway  

International Nuclear Information System (INIS)

Unit one of Daya Bay, China's first nuclear power plant was officially opened in February 1994. The nuclear island has been built by Framatome and is an improved version of the Gravelines 5 and 6, 900MWe Pressurized Water Reactors. Extra seismic protection has been included because of greater earthquake risk. The heat exchanger capacity has also been increased as the sea cooling water can be at 30"oC. The technical specifications and details of the fuel loading are given. The technical assistance, management and training of Chinese personnel are discussed. Two further units may be built if Daya Bay 1 is successful. (UK).

49

Solar desalination using humidification dehumidification processes. Pt. 1. A numerical investigation  

Energy Technology Data Exchange (ETDEWEB)

A numerical investigation of a humidification dehumidification desalination (HDD) process using solar energy is presented. The HDD system consists mainly of a concentrating solar water heating collector, flat plate solar air heating collector, humidifying tower and dehumidifying exchanger. Two separate circulating loops constitute the HDD system, the first for heating the feed water and the second for heating air. A mathematical model is developed, simulating the HDD system, to study the influence of the different system configurations, weather and operating conditions on the system productivity. The model validity is examined by comparing the theoretical and experimental results of the same authors. It is found that the results of the developed mathematical model are in good agreement with the experimental results and other published works. ...

2004-05-01

50

Solar desalination using humidification dehumidification processes. Part I. A numerical investigation  

Energy Technology Data Exchange (ETDEWEB)

A numerical investigation of a humidification dehumidification desalination (HDD) process using solar energy is presented. The HDD system consists mainly of a concentrating solar water heating collector, flat plate solar air heating collector, humidifying tower and dehumidifying exchanger. Two separate circulating loops constitute the HDD system, the first for heating the feed water and the second for heating air. A mathematical model is developed, simulating the HDD system, to study the influence of the different system configurations, weather and operating conditions on the system productivity. The model validity is examined by comparing the theoretical and experimental results of the same authors. It is found that the results of the developed mathematical model are in good agreement with the experimental results and other published works. ...

2004-05-01

51

Process for repairing a cryogenic heat exchanger  

International Nuclear Information System (INIS)

The patent describes a method for repairing leakage-causing cracks and fissures in a cryogenic heat exchanger. It comprises: reducing the interior pressure of the heat exchanger to a level which does not exceed the external pressure upon the hear exchanger while maintaining the temperature of the heat exchanger at a low level relative to the ambient external temperature; applying a curable liquid filler composition to the surface of the heat exchanger proximal the leakage site for seepage into the cracks and fissures located at the leakage. The composition upon a relatively short period of cure at low temperature forming a solid material which fills the cracks and fissures; curing the filler composition; and, applying a sealant composition to the surface of the heat ...

1987-10-13

52

Optimal thermodynamic heat transfer  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a set of heuristics useful for optimal design of heat-exchange networks and integrated heat and power systems. These heuristics consolidate other approaches reported in the literature in a formalism useful for design purposes.

1989-06-01

54

Numerical investigation of the impact of gas and cooling flow configurations on current and water distributions in a polymer membrane fuel cell through a pseudo-two-dimensional diphasic model  

British Library Electronic Table of Contents (United Kingdom)

For optimal performances, proton exchange membrane fuel cells require fine water and thermal management. Accurate modelling of the physical phenomena occurring in the fuel cell is a key issue to improve fuel cell technology. Here, an analytic steady state diphasic 2D model of heat and mass transfer is presented. Through this model, the aim of this work is to study the influence of local events on the global performances of a fuel cell. A part of the complete model is a microscopic representation of the coupling between water transport and charge transfers in the electrodes. The thickness of the liquid layer around the reactive agglomerates is deduced from the saturation. The evolution of the quantity of water within the catalyst layer is monitored and its influence on the global performanc...

2010-01-01

55

Exergy analysis of the solar multi-effect humidification?dehumidification desalination process  

British Library Electronic Table of Contents (United Kingdom)

An exergy analysis method is presented of the solar multi-effect humidification?dehumidification desalination (HDD) process. Pinch technology is used in the humidification process to determine the maximum possible saturated air temperature and the temperature of water rejected from the unit, and then the dehumidification process to determine the temperature of water leaving from the heat exchanger. The formulae to calculate the exergy of water and saturated air are given. The solar plane collector is used. From exergy analysis, the solar collector has the lowest exergy efficiency; the HDD process has a lower exergy efficiency, and the water rejected has also a large exergy loss. The energy and exergy recovery rate of the desalination process is also lower. The solar multi-effect HDD proces...

2007-01-01

56

CFD simulation of flow distribution in the header of plate-fin heat exchangers  

Energy Technology Data Exchange (ETDEWEB)

The flow distribution through a plate-fin heat exchanger is studied by using a computational fluid dynamics (CFD) code, FLUENT. The flow distribution through any heat exchanger affects its performance. In designing a heat exchanger, it is assumed that the fluid is uniformly distributed through the heat exchanger core. In practice, however, it is impossible to distribute fluid uniformly, because of an improper inlet configuration, imperfect design, and a complex heat transfer process. The CFD simulation of the flow distribution in the header of a conventional plate-fin heat exchanger is presented. It is found that the flow maldistribution is very serious in the y-direction of the header. A modified header is proposed and simulated using CFD. The modified ...

2007-10-15

57

Restoration of a forested wetland ecosystem in a thermally impacted stream corridor  

Energy Technology Data Exchange (ETDEWEB)

The Savannah River Swamp is a 3,020 Ha forested wetland on the floodplain of the Savannah River and is located on the Department of Energy`s Savannah River Site (SRS). Major impacts to the swamp hydrology occurred with the completion of the production reactors and one coal-fired powerhouse at the SRS in the early 1950`s. Water was pumped from the Savannah River, through secondary heat exchangers of the reactors, and discharged into three of the tributary streams that flow into the swamp. This continued from 1954 to 1988 at various levels. The sustained increases in water volume resulted in overflow of the original stream banks and the creation of additional floodplains. Accompanying this was considerable erosion of the original stream corridor and deposition of a deep silt layer on the newly formed delta. Heated water was discharged directly into Pen Branch and ...

1995-09-01

58

Selecting the Design Entering Water Temperature for Vertical Geothermal Heat Pumps in Cooling-Dominated Applications  

International Nuclear Information System (INIS)

At a military base in the Southeastern US, an energy services company (ESCO) has proposed to retrofit more than 1,000 family residences with geothermal heat pumps as part of an energy savings performance contract (ESPC). Each residence is to have one heat pump with its own ground heat exchanger consisting of two or more vertical bores. A design firm hired by the ESCO sized the heat pumps to meet peak cooling loads, and sized the borefields to limit the maximum entering water temperature (EWT) to the heat pumps to 95 F (35 C). Because there is some disagreement in the geothermal heat pump industry over the peak temperature to be used for design (some designers and design manuals recommend temperatures as low as 85 F[29 C], while equipment manufacturers and others specify temperatures of 100 F[38 C] or higher) the authors ...

59

Influence of suspended solids on pitting corrosion of carbon steel in cooling water. Tansoko no koshoku ni oyobosu reikyaku suichu no kendaku busshitsu no eikyo  

Energy Technology Data Exchange (ETDEWEB)

A large amount of industrial water is used for cooling the various process fluids in the petroleum purification factories as well as petroleum chemistry factories. Consequently, a lot of heat exchangers as the necessary constitutional instruments are made of carbon steel. Due to the most of the corrosions of the carbon steel occurring in such cooling water systems are pitting corrosions, the inhibition thereof is extremely important for the elongation of the life of the plants and the stable operation. In this paper, the influences of water quality fractions on pitting corrosion of carbon steel in cooling water circumstance are examined aiming at the fouling in the cooling water. The fouling in the cooling water does not only increase the amount of occurrence of pitting corrosion but also accelerates the progress of ...

1993-08-15

60

The effect of flow-hole structure and water chemistry on scale adhesion at the leading edge of a flow hole in a heat exchanger  

International Nuclear Information System (INIS)

In the heat exchangers of power plants, scale deposition may occur, especially at the leading edge of contraction. The growth of scale can lead to an increase in pressure and cause oscillation of the water level. In our previous study, the dependence of flow on contraction geometry was analyzed numerically and empirically. It was shown that the contraction ratio of hydraulic diameter of the flow path contributed greatly to the difference in pressure drop and turbulent kinetic energy at the leading edge of the flow path. In this study, the effect of contraction geometry and flow rate on scale adhesion was studied in AVT chemistry at 270degC using a high-velocity scale-adhesion test loop. The differential pressure and the amount of scale deposited due to scale adhesion at the leading edge of the flow path increased more in a quatrefoil-type flow path than in drill-type flow path. The differential pressure and the amount of ...

1999-05-01

61

Flow Vaporization of CO{sub 2} in Microchannel Tubes  

Energy Technology Data Exchange (ETDEWEB)

Carbon dioxide is receiving renewed interest as an efficient and environmentally safe refrigerant in a number of applications, including mobile air conditioning and heat pump systems, and hot water heat pumps. Compact heat exchangers for CO{sub 2} systems are designed with small-diameter tubing. The purpose of this study is therefore to provide a better basis for understanding and predicting heat transfer and pressure drop during flow vaporization of CO{sub 2} in microchannels. The ''unusual'' properties of carbon dioxide give heat transfer and two-phase flow characteristics that are very different from those of conventional refrigerants. Examples of these differences are the much higher pressure, the resulting high vapour density, a very low surface tension, and a low liquid viscosity. High pressure and ...

2002-07-01

62

Guidelines on exchangers  

Energy Technology Data Exchange (ETDEWEB)

Experience has shown that a list of tips provides designers and engineers with an effective guide in their areas of duties and concern. This list contains new and rare information on heat exchangers and heat recovery systems. The information presented can be used effectively with personal computers and pocket calculators and also conveniently translated into computer programs and nomographs.

1985-08-01

63

Analysis and optimization of the heat transfer coefficient of a finned heat exchanger submitted to natural convection; Analise e otimizacao do coeficiente de transferencia de calor de um trocador aletado submetido a conveccao natural  

Energy Technology Data Exchange (ETDEWEB)

A heat transfer (condenser) of a domestic freezer was tested in a vertical channel in order to study the influence of the chimney effect in the optimization of the heat transfer coefficient. The variation of the opening of the channel, position and the heating power of the heat exchanger in the heat transfer coefficient was considered. The influence of the surface emissivity on the heat transfer by thermal radiation was studied with the heat exchanger testes without paint and with black paint. The air velocity entering the channel was measured with a hot wire anemometer. In order to evaluate the chimney effect, the heat exchanger was testes in a open ambient. This situation simulates its operational conditions when installed on the freezer system. The ...

1997-07-01

65

Compact heat exchangers for condensation applications: Yesterday, today and tomorrow  

Energy Technology Data Exchange (ETDEWEB)

Compact heat exchangers are being increasingly considered for condensation applications in the process, cryogenic, aerospace, power and refrigeration industries. In this paper, different configurations available for condensation applications are analyzed and the current state-of-the-knowledge for the design of compact condensers is evaluated. The key technical issues for the design and development of compact heat exchangers for condensation applications are analyzed and major advantages are identified. The experimental data and performance prediction methods reported in the literature are analyzed to evaluate the present design capabilities for different compact heat-exchanger configurations. The design flexibility is evaluated for the development of new condensation applications, including integration with other process equipment.

1993-07-01

66

Initiation process of type 1 pitting corrosion on copper water-tubes; Reisui yo dokan ni okeru 1 gata koshoku no hassei  

Energy Technology Data Exchange (ETDEWEB)

Copper tubes have been widely used for water supply and heat exchangers. In such systems copper tubes often suffer from type 1 pitting-corrosion. A mechanism, of the type I pitting-corrosion on copper tubing has been presented, but a initiation mechanism of the pitting corrosion is still unknown. In this paper we aimed to clarify the initiation mechanism of the pitting corrosion. Copper-tube specimens were immersed in a circulating solution. The solution had been used for heat exchangers at a Japanese factory where the water leakage occurred by the pitting corrosion on copper tubes. The solution contained tiny precipitates resulted from corrosion of galvanized steel pipe. During the immersion test changes in the surface state of a copper tube was analyzed by in situ RAMAN (in situ Raman Spectroscopy), SEM (Scanning Electron Microscope), EPMA (Electron Probe ...

1999-07-15

67

Device for energy-saving heating of fuel in the fuel supply for an internal combustion engine  

Energy Technology Data Exchange (ETDEWEB)

The invention concerns a device for the energy-saving heating of fuel in the supply pipe to an internal combustion engine to regain energy from the fuel itself, particularly but not exclusively for a Diesel engine. A part of the quantity of heat added to the fuel between the tank and the injection nozzles is given up by excess fuel not to the tank, but to the fuel lifted upstream of the injection pump. The device is characterised by the fact that it has a heat exchanger, which absorbs heat from the fuel at the level of the injection pump or upstream of it, and takes this to the fuel above the injection pump. The heat exchanger is preferably mounted upstream of a filter and close to it. A bridging pipe, which may be integrated in the heat exchanger, permits the heat ...

1981-02-10

68

Heat transfer. Fundamentals. 5. rev. ed.  

International Nuclear Information System (INIS)

This textbook contains the following main topics: Heat conductivity, convection, condensation and evaporation, radiation heat transfer and heat exchangers. It includes the physical foundations for all these aspects and many examples. (orig.)

69

Heat transfer augmentation by gas-particle two-phase flow  

International Nuclear Information System (INIS)

The helium-cooled HTGR (High Temperature Gas-cooled Reactor) will take an important position in the global energy strategy. It is expected to supply not only electricity but also high quality thermal energy for various industries and local utilities without exhausting any green house effect gas or acid rain gas. The key R and D issue of the HTGR is economical competitiveness, particularly against light water reactors. Due to the poor heat transfer of the single phase helium, the HTGR's volumetric power density is restricted to tenth of corresponding PWR's value so that increasing the power density by improving heat transfer is strongly desired. The standstill can be broken through by adopting gas-solid suspension medium. Its heat transfer performance is quite excellent. Its heat capacity can be increased drastically without excessive pressurization. Although the thermal radiation is ...

1995-06-01

70

Research on regimes transition of the boiling water two-phase flow in horizontal rectangular narrow heated channels  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: The heat transfer and flow in narrow channels has lots of advantages such as compact structure, high efficiency, design flexibility and so on. So it is widely used in the fields such as the new reactor core plate elements, the once-through stream generator, compact heat exchangers as well as electronic components. In recent years, more strong attentions have been attracted to the thermal-hydraulic characteristics and mechanism of the two-phase flow in narrow channels. As the flow regime characteristics of two-phase flow is fundamental one of them, the research on the two-phase flow regimes and the regime transitions in horizontal rectangular narrow heated channels can provide theoretical foundation and engineering directions to the whole research on the thermal-hydraulic characteristics and mechanism of the two-phase flow in narrow channels. The characteristics of ...

2005-07-01

71

Research on regimes transition of the boiling water two-phase flow in horizontal rectangular narrow heated channels  

International Nuclear Information System (INIS)

Full text of publication follows: The heat transfer and flow in narrow channels has lots of advantages such as compact structure, high efficiency, design flexibility and so on. So it is widely used in the fields such as the new reactor core plate elements, the once-through stream generator, compact heat exchangers as well as electronic components. In recent years, more strong attentions have been attracted to the thermal-hydraulic characteristics and mechanism of the two-phase flow in narrow channels. As the flow regime characteristics of two-phase flow is fundamental one of them, the research on the two-phase flow regimes and the regime transitions in horizontal rectangular narrow heated channels can provide theoretical foundation and engineering directions to the whole research on the thermal-hydraulic characteristics and mechanism of the two-phase flow in narrow channels. The characteristics of ...

2005-10-02

72

Interface heat transfer of horizontal co-current liquid-liquid stratified flow. II - Entrance region  

Science.gov (United States)

Flow structures and heat transfer at the liquid-liquid interface are investigated experimentally and analytically in the entrance region of a liquid metal-water stratified flow in a horizontal rectangular channel. The two-equation model and the mixing length mode, including a damping turbulent region near the interface, are used to obtain analytical results for pressure drop, position of the interface, and heat transmission coefficients across the interface. Analytical results are compared with experimental results. Conclusions are presented and include the following: (1) vertical position of the interface increases or decreases along the stream according to the fluid flow rate of both fluids, and then approaches a constant value in the fully developed region; (2) pressure drop increases along the stream from the minimum value at the inlet; and (3) heat transmission coefficients across the interface ...

1981-06-01

73

Brief guide to the MINC-method for modeling flow and transport in fractured media  

Science.gov (United States)

MINC stands for Multiple INteracting continua.'' It is an approximate method for modeling fluid and heat flow in fractured- porous media, developed by Pruess and Narasimhan (1982, 1985) at the Lawrence Berkeley Laboratory. The method is applicable to flow processes in which an important aspect is the exchange of fluid, heat, or chemical species between fractures and unfractured rock. Examples include production and injection operations in fractured geothermal reservoirs, water-flooding, steamflooding, and other methods for enhanced oil recovery from fractured reservoirs, as well as chemical transport and contaminant migration in fractured rock. MINC can only be applied to media in which the fractures are sufficiently well connected so that a continuum treatment of flow in the fracture network can be made.

1992-05-01

74

Universal model for water costs of gas exchange by animals and plants  

UK PubMed Central (United Kingdom)

For terrestrial animals and plants, a fundamental cost of living is water vapor lost to the atmosphere during exchange of metabolic gases. Here, by bringing together previously developed models for...Full Text Available

2010-05-04

75

Examination of transepithelial exchange of water and solute in the rat renal pelvis.  

UK PubMed Central (United Kingdom)

Severance of the ureter beyond the renal papilla causes a fall in urinary osmolality, which suggests that exchange of water or solute between urine and renal parenchyma normally occurs in the intact...Full Text Available

1984-11-01

76

Analysis of a bayonet tube heat exchanger  

Energy Technology Data Exchange (ETDEWEB)

This paper details the design, construction and testing of a bayonet tube heat exchanger for use in the process industry and potentially as part of an externally fired combined cycle. Detailed analysis of the system has been undertaken, in particular on the tube side. The data is reported in terms of temperature, pressure, heat gain and heat exchanger effectiveness, over a range of Reynolds numbers and shell side mixture ratios. Much of the heat gained by the tubes is in the annular flow of the bayonet tube. Overall the effectiveness of this system could exceed 70%. (Author)

2001-01-01

77

Corrosion damage assessment of WWER steam generator primary collectors  

Energy Technology Data Exchange (ETDEWEB)

Titanium stabilized austenitic steel is sensitive to SCC in the secondary water under the horizontal steam generator operating conditions. SCC was observed under crevice conditions both at the primary collector flanges and the heat exchange tubes. In the crevice environment sulfates and chlorides as aggressive species and silicates and alumino-silicates as ''non-aggressive'' species are present in significant amounts. Local water chemistry parameters were evaluated using the MULTEQ Code. SCC experiments were carried out by rising displacement tests ar 275 deg C in an environment simulating the crevice conditions. Crack growth rate and K{sub IS}8C{sub C} were determined for the environment where contents of some species were from 10{sup 2} to 10{sup 4} times higher than in blowdowns. (authors)

1998-07-01

78

Corrosion damage assessment of WWER steam generator primary collectors  

International Nuclear Information System (INIS)

Titanium stabilized austenitic steel is sensitive to SCC in the secondary water under the horizontal steam generator operating conditions. SCC was observed under crevice conditions both at the primary collector flanges and the heat exchange tubes. In the crevice environment sulfates and chlorides as aggressive species and silicates and alumino-silicates as ''non-aggressive'' species are present in significant amounts. Local water chemistry parameters were evaluated using the MULTEQ Code. SCC experiments were carried out by rising displacement tests ar 275 deg C in an environment simulating the crevice conditions. Crack growth rate and K_I_S8C_C were determined for the environment where contents of some species were from 10"2 to 10"4 times higher than in blowdowns. (authors)

1998-09-14

79

Analysis of polyelectrolyte complexes formed with jicama pectic polysaccharide and water-soluble chitosan  

British Library Electronic Table of Contents (United Kingdom)

Abstract Jicama (Pachyrhizus erosus L.) is a root-based legume that has been cultivated in Mexico for centuries. Pectic polysaccharide from de-starched jicama pomace was extracted using an autoclave-assisted process and physicochemically characterized. The extracted polysaccharide (1.0 g L-1) was used for the formation of polyelectrolyte complexes (PECs) with water-soluble chitosan (WSCh; 0.5, 1.0 and 2.0 g L-1). The extraction yield of jicama pectic polysaccharide was 22.8 wt% (dry basis) and infrared spectroscopic analysis showed that it was methoxylated to a small degree. Thermogravimetric analysis indicated that this biopolymer was very stable, its weight loss being 51.2% after heating at 479 C. Anion-exchange chromatography showed it to have a wide and heterogeneous charge density. Th...

2011-01-01

80

Relaxation and corrosion resistance of alloy 800 used for steam generator tubes of ship borne boilers  

Energy Technology Data Exchange (ETDEWEB)

The INCO ``INCOLOY 800`` trademark groups the Fe-Cr-Ni alloys containing 30 to 35% nickel, 19 to 23% chromium, 0,15 to 0,60% aluminium, 0,15 to 0,60% titanium and less than 0,10% carbon contents, used as construction materials for condenser and heat exchanger tubes. In parallel with water chemistry control and studies aimed at reducing the residual stresses resulting from tube expansion, studies have been conducted to a better understanding of this alloy, its metallurgy and its corrosion behaviour under accurately defined fabrication and heat treatment conditions. The purpose of this paper is to present the results of a behaviour study of INDRET alloy 800 concerning isothermal relaxation and effects of the said relaxation heat treatments on alloy microstructure studied with a transmission electron-chemical method to determine the sensitiveness to intergranular corrosion, and by ...

1994-12-31

81

Serviceability of steam generators at NPPs with reactors of the WWER-440 and WWER-1000 types  

Energy Technology Data Exchange (ETDEWEB)

Steam generators (SG) are the weak link of nuclear power plants, their service life is shorter than the service life of other NPP components. This paper is dedicated to a statistical analysis of SG damages and failures. Heat exchanging tubes (HET) are the most damaged elements in SG, there are on average 286 plugged or repaired tubes in each operating SG. The usually mechanisms of tube failure are the following: denting, corrosion at tube outside, pitting, fretting, and circular crack propagation. Most of damages are located in the transition zone above a tube plate. This study shows that the factors that are involved in the SG HET fault probability are: - design features of SG and secondary equipment elements (high pressure feed heaters (HPFH), low pressure feed heater (LPFH)), - water chemistry at different points of condensate feed pipe, composition and density of deposits on HET surface, efficiency of mechanical and ...

2002-07-01

82

Flow induced vibration mock-up test for heat exchanger tubes of PWR steam generator  

International Nuclear Information System (INIS)

It is one of the most important subjects to estimate the flow-related stability of the heat exchanger tubes. A large scale model steam generator has been developed to verify the stability of the tubes in the Japanese PWR steam generators for the two-phase flow-induced vibration and to accumulate related technical data of thermal-hydraulic and flow-induced vibration of U-bend tube bundle. The model steam generator has 230 U-bend tubes of 46 different radius and 5 columns for each of practical diameter and material, and the anti vibration bars are inserted into each spacing between tube arrays. The freon R123 has been used as the secondary side fluid in stead of water-steam two-phase. In the test, void fraction and interfacial velocities in U-bend and straight tube-bundle are measured with bi-optical probes, and vibration responses of some selected tubes are measured with strain gauges and accelerators. It is verified that ...

2000-10-01

83

Advances in enhanced heat transfer: 1987  

Energy Technology Data Exchange (ETDEWEB)

This book contains nine selections. Some of the titles are: High Heat-Flux, Forced-Convection Heat Transfer for Tubes with Twisted-Tape Inserts; Heat Transfer Augmentation by Interrupted Surfaces - Experimental Consideration; Turbulent Flow Heat Transfer from Externally Roughened Tubes in Axial Flow in Concentric Pipe Heat Exchangers; and Heat Transfer Enhancement of Turbulent Flow in Pipes with an Internal Circular Rib.

1987-01-01

84

Advances in enhanced heat transfer: 1987  

International Nuclear Information System (INIS)

This book contains nine selections. Some of the titles are: High Heat-Flux, Forced-Convection Heat Transfer for Tubes with Twisted-Tape Inserts; Heat Transfer Augmentation by Interrupted Surfaces - Experimental Consideration; Turbulent Flow Heat Transfer from Externally Roughened Tubes in Axial Flow in Concentric Pipe Heat Exchangers; and Heat Transfer Enhancement of Turbulent Flow in Pipes with an Internal Circular Rib.

1987-08-09

85

Numerical and experimental investigation of shellside characteristics for RODbaffle heat exchanger  

Energy Technology Data Exchange (ETDEWEB)

RODbaffle heat exchanger is a kind of shell-and-tube heat exchanger with eminent performance. Because of the characteristics of tube bundle support structure, fluid flow on shellside is longitudinal and periodical, and fluid flow is of symmetry in landscape orientation. According to the fluid flow characteristics on shellside and ignoring the impact of inlet, outlet and shell wall, a periodic flow unit duct was taken as the simplified model of the shellside to perform numerical simulation by using CFD code, FLUENT. It was found that the both errors in magnitude of the main fluid velocities and heat transfer coefficients between results of simulation and that of experiment or correlations are less than 10%, and the errors of pressure drop between simulation and correlation are no more than 20%. The detailed characteristics and relation of fluid flow and heat ...

2008-05-15

86

Development of a geothermal heat pump. Final report  

Energy Technology Data Exchange (ETDEWEB)

In the development of a geothermal heat pump a water source heat pump was connected to a 1-1/2'' water line, 2200' long, buried in an endless loop 10' deep. The system is closed, circulating the same water continuously through the heat pump back to the field again. This water line 10' deep is the geothermal heat source. No matter how cold the air temperature gets on a winter day the water temperature to the heat pump will always be above 45/sup 0/F. This system has efficiently heated our house the past year using no supplemental heat.

1981-11-02

87

Post-CHF Heat Transfer characteristics in one rod bundle geometry  

Energy Technology Data Exchange (ETDEWEB)

In the present paper, experimental study of forced convection boiling were performed to investigate the post-CHF characteristics of a vertical annular channel with one heated rod and four spacer grids for new refrigerant R-134a. The experiments were conducted under outlet pressure of 11.6, 13, 16 and 20 bar, mass fluxes of 100-600 kg/m{sup 2}s, and inlet temperatures of 25-51 .deg. C. The parametric trend of the post-CHF data was well consistent with previous studies. The two phase flow regime in tube flow occurring downstream of the CHF has been called post-CHF, dispersed flow, liquid-deficient flow, mist flow and film boiling. This regime is characterized by a continuous vapor phase with discrete liquid drops and a non-wetted heated surface. This regime has a considerable importance in the areas of light water reactor(LWR) accident analysis and other film boiling applications. The post-CHF region occurs by design in ...

2006-07-01

88

Post-CHF Heat Transfer characteristics in one rod bundle geometry  

International Nuclear Information System (INIS)

In the present paper, experimental study of forced convection boiling were performed to investigate the post-CHF characteristics of a vertical annular channel with one heated rod and four spacer grids for new refrigerant R-134a. The experiments were conducted under outlet pressure of 11.6, 13, 16 and 20 bar, mass fluxes of 100-600 kg/m2s, and inlet temperatures of 25-51 .deg. C. The parametric trend of the post-CHF data was well consistent with previous studies. The two phase flow regime in tube flow occurring downstream of the CHF has been called post-CHF, dispersed flow, liquid-deficient flow, mist flow and film boiling. This regime is characterized by a continuous vapor phase with discrete liquid drops and a non-wetted heated surface. This regime has a considerable importance in the areas of light water reactor(LWR) accident analysis and other film boiling applications. The post-CHF region occurs by design in ...

2006-11-02

89

A thermal valve heat flux control device  

International Nuclear Information System (INIS)

In order to evacuate the residual power in a nuclear reactor, a thermal valve system is presented for the modification of the heat exchange conditions at the pool exchanger level, which avoids the use of mechanical valves on the pipes. The system involves a vessel containing the exchanger, with openings at the upper end of the vessel and means for feeding the fluid at the lower end, and means for controlling the opening width.

1994-10-05

90

Hybrid solar/combustion powered receiver  

Energy Technology Data Exchange (ETDEWEB)

An improved hybrid solar/combustion powered receiver of the type having an insulated housing with a front end and a rear end, a heat exchanger positioned adjacent the rear housing end for extracting heat energy out of the receiver, the insulated housing surrounding the heat exchanger and forming a receiver cavity, the housing also including an aperature having an aperture axis, the aperture located in the front housing end for admitting solar radiation to the cavity to impinge upon the heat exchanger, and a plurality of gas burners to provide combustion gases within the receiver.

1986-07-29

91

Operating experience with solidification of radioactive waste by a thin-film evaporator  

Energy Technology Data Exchange (ETDEWEB)

In the nuclear power stations of GDR the rough radioactive waste includes borat-containing evaporator bottoms and spent ion exchanger resins. For its final disposal in deep geological formations (rock salt mines) this waste has to be solidified. The experience of one year lasting operation of a steam heated thin-film evaporator (heating surface 2 m{sup 3}) for evaporator bottoms to be solidified with a solid content of 200-250 g/l are reported on. In short time such amount of water is abstracted from the rough waste that due to the borate content a hot high-viscous product passes from evaporator to waste drum and there solidifies like glass to monolith. The product quality depends on the adjustment of the flow-equilibrium in the evaporator. Boric acid is used as matrix for the radioactive residues. The residual water content of the solidified waste product was about 15-20%, the ...

1990-01-01

92

Operating experience with solidification of radioactive waste by a thin-film evaporator  

International Nuclear Information System (INIS)

In the nuclear power stations of GDR the rough radioactive waste includes borat-containing evaporator bottoms and spent ion exchanger resins. For its final disposal in deep geological formations (rock salt mines) this waste has to be solidified. The experience of one year lasting operation of a steam heated thin-film evaporator (heating surface 2 m"3) for evaporator bottoms to be solidified with a solid content of 200-250 g/l are reported on. In short time such amount of water is abstracted from the rough waste that due to the borate content a hot high-viscous product passes from evaporator to waste drum and there solidifies like glass to monolith. The product quality depends on the adjustment of the flow-equilibrium in the evaporator. Boric acid is used as matrix for the radioactive residues. The residual water content of the solidified waste product was about 15-20%, the volume ...

1990-06-01

93

Heat exchange enhancement structure  

Energy Technology Data Exchange (ETDEWEB)

A passive heat exchange enhancement structure which operates by free convection includes a flat mounting portion having a plurality of integral fins bent outwardly from one side edge thereof. The mounting portion is securable around a stovepipe, to a flat surface or the like for transferring heat from the pipe through the fins to the surrounding air by rotation-enhanced free convection.

1980-12-02

94

Microclimatic models. Estimation of components of the energy balance over land surfaces  

Energy Technology Data Exchange (ETDEWEB)

Climates at regional scale are strongly dependent on the interaction between atmosphere and its lower boundary, the oceans and the land surface mosaic. Land surfaces influence climate through their albedo, and the aerodynamic roughness, the processes of the biosphere and many soil hydrological properties; all these factors vary considerably geographically. Land surfaces receive a certain portion of the solar irradiance depending on the cloudiness, atmospheric transparency and surface albedo. Short-wave solar irradiance is the source of the heat energy exchange at the earth`s surface and also regulates many biological processes, e.g. photosynthesis. Methods for estimating solar irradiance, atmospheric transparency and surface albedo were reviewed during the course of this project. The solar energy at earth`s surface is consumed for heating the soil and the lower atmosphere. Where moisture is available, evaporation is one of ...

1996-12-31

95

Heat transfer equipment design  

Energy Technology Data Exchange (ETDEWEB)

A comprehensive presentation is made of state-of-the-art configurations and design methodologies for heat transfer devices applicable to industrial processes, automotive systems, air conditioning/refrigeration, cryogenics, and petrochemicals refining. Attention is given to topics in heat exchanger mechanical design, single-phase convection processes, thermal design, two-phase exchanger thermal design, heat-transfer augmentation, and rheological effects. Computerized analysis and design methodologies are presented for the range of heat transfer systems, as well as advanced methods for optimization and performance projection.

1988-01-01

96

Visualization and void fraction measurements of refrigerant flow in a refrigerator by neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

The refrigerant two-phase flows in a distributor and a simulated plate heat exchanger with a single passage used in a compression-type refrigerator were visualized by real-time neutron radiography. For a distributor, the liquid fraction in the each tube was measured by some image processing method. On the other hand, for a plate heat exchanger, the two-dimensional distribution of void fraction was measured quantitatively by the umbra method. As a result, it was shown that the dynamic behaviors of refrigerant at the inlet of the section strongly affected on the performance, that is, a distribution performance of a distributor and a liquid distribution in a plate heat exchanger. (author)

2000-07-01

97

Heat exchanger tube vibration: comparison between operating experiences and vibration analyses  

International Nuclear Information System (INIS)

Tube failures due to excessive flow-induced vibration must be avoided to assure the reliable performance of heat exchangers. Such components must be thoroughly analysed for vibration at the design stage. Several flow-induced vibration mechanisms are possible. In this paper, particular attention is given to fluidelastic instability of tube bundles subjected to liquid and two-phase cross-flow. The performance of ten operating heat exchanger components is reviewed to validate our recommended vibration analysis guidelines. Both tube failure histories and satisfactory performances are considered. The results show that a fluidelastic instability constant K=3.3 is a reasonable design criterion. (auth).

1992-12-01

98

Superphenix 1 steam generator fabrication  

Energy Technology Data Exchange (ETDEWEB)

The Superphenix 750-MW (thermal), once-throughtype steam generators are the result of over 10 years of intensive research and development. Detailed design and manufacture of the components lasted from 1977 to 1982. The main difficulties encountered during the construction of these prototype units concerned: demonstration of satisfactory high-temperature properties of Alloy 800 tubes; proven resistance of tube welds to thermal fatigue and of structures and shells to sodium/ water reaction effects; prevention of the tube bundle to flow-induced vibration; necessity of manual welding of shells to prevent hot cracking hazards related to the boron content of the steel; and welding of heat exchange tubes. None of these difficulties, however, invalidated initial major design choices, but provided a wealth of technical and technological experience and knowledge for the steam generators of the future. Plans for the future include ...

1985-02-01

99

Numerical heat transfer studies of the fatty acids for different heat exchanger materials on the performance of a latent heat storage system  

Energy Technology Data Exchange (ETDEWEB)

Theoretical investigations of fatty acids as a phase change material (PCM) for energy storage system have been conducted in this study. The selected fatty acids were capric acid, lauric acid, myristic acid, palmitic acid and stearic acid. For the two-dimensional simulation model based on the enthalpy approach, calculations have been made for the melt fraction with conduction only. Glass, stainless steel, tin, aluminium mixed, aluminium and copper were used as heat exchanger materials in the numerical calculations. Theoretical results show that capric acid was found good compatibility with latent heat storage system. The large value of thermal conductivity of heat exchanger materials did not make significant contribution on the melt fraction. (author)

2005-11-01

100

The National Shipbuilding Research Program Task S-20: A ...  

Science.gov (United States)

... The other standards in this group deal with heat exchangers, insulation, marking, valves, hydraulic cleanliness, storage of LPG, and centrifugal fire ...

1979-05-01

102

Onboard fuel reformers for fuel cell vehicles: Equilibrium, kinetic and system modeling  

Energy Technology Data Exchange (ETDEWEB)

On-board reforming of liquid fuels to hydrogen for use in proton exchange membrane (PEM) fuel cell electric vehicles (FCEVs) has been the subject of numerous investigations. In many respects, liquid fuels represent a more attractive method of carrying hydrogen than compressed hydrogen itself, promising greater vehicle range, shorter refilling times, increased safety, and perhaps most importantly, utilization of the current fuel distribution infrastructure. The drawbacks of on-board reformers include their inherent complexity [for example a POX reactor includes: a fuel vaporizer, a reformer, water-gas shift reactors, a preferential oxidation (PROX) unit for CO cleanup, heat exchangers for thermal integration, sensors and controls, etc.], weight, and expense relative to compressed H{sub 2}, as well as degraded fuel cell performance due to the presence of inert gases and impurities in the reformate. ...

1996-12-31

103

Heat transfer  

Energy Technology Data Exchange (ETDEWEB)

Heat transfer has emerged as a leading-edge technology supporting the rapid pace of developments in science and engineering ranging from energy production to electronic cooling. Subjects covered at the 6th UK National Conference on heat transfer held at Edinburgh from 15-16 September 1999 include: convection; boiling and evaporation; condensation; numerical techniques; heat exchangers; radiation and combustion; conduction; two-phase flow and heat transfer augmentation. Fifteen of the papers are abstracted here.

1999-07-01

104

Metal Foam Heat Exchangers for Heat Transfer Augmentation from a Cylinder in Cross-Flow  

British Library Electronic Table of Contents (United Kingdom)

A numerical study has been conducted to examine the heat transfer from a metal foam-wrapped solid cylinder in cross-flow. Effects of the key parameters including the free stream velocity and characteristics of metal foam such as porosity, permeability, and form drag coefficient on heat and fluid flow are examined. Being a determining factor in pressure drop and heat transfer increment, the porous layer thickness is changed systematically to observe that there is an optimum layer thickness beyond which the heat transfer does not improve while the pressure drop continues to increase. This has been verified by the application of Bejan?s Intersection of Asymptotes method. Results have been compared to those of a finned-tube heat exchanger to observe much higher heat transfer rate with reasonab...

2011-01-01

105

Radionuclide X-ray fluorescence analysis of drinking water using preconcentration of trace metals on chelating cellulose exchanger ostsorb-oxin  

International Nuclear Information System (INIS)

Determination of Cr, Fe, Cu, Zn and Pb in drinking water preconcentrated on a chelating ion exchanger of Czechoslovak production is described. The analytical system consisted of a radionuclide source "2"3"8Pu, a Si/Li semiconductor detector and a multichannel analyzer. Results are compared with trehshold limit values recommended for drinking water. (author) 9 refs.; 2 figs.

1992-04-01

106

National Earth Comfort Program, Geothermal Heat Pump Market Mobilization and Technology Demonstration  

Energy Technology Data Exchange (ETDEWEB)

Late 1994, the Geothermal Heat Pump Consortium (GHPC) was launched as a non-profit collaborative effort between the United States Department of Energy, US electric utilities and the GeoExchange (geothermal heat pump) industry to make ''geothermal heat pumps'' a significant component of the HVAC industry and avoid 1.5 million metric tons of carbon equivalent per year. The goal was to create a self-sustainable GeoExchange market. This report offers a summary of some of the lessons learned and an overview of some of the programs major accomplishments.

2001-04-30

108

Enhancement of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 (16N) and Oxygen-19 (19O) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of 19O and 16N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high ambient radiation level even though sensitivity is appreciably good. For detector position in ...

2006-11-13

109

Boiling heat transfer in a small horizontal rectangular channel  

Energy Technology Data Exchange (ETDEWEB)

Compact heat exchangers have traditionally found wide application in the transportation industry, where they are used as evaporators and condensers in vapor compression cycles for air conditioning and refrigeration. Such heat exchangers possess numerous attractive features including high thermal effectiveness, small size, low weight, design flexibility, and pure counterflow, and they can accommodate multiple streams. Today, there is a widespread interest in expanding the range of application of compact heat exchangers to include phase-change heat transfer in the process industries, among others. An overall objective of this effort is to provide the basis for establishing design technology in this area. In the present study, small channel flow boiling heat transfer was extended to a rectangular channel (4.06 {times} 1.70 ...

1993-08-01

110

Thermal performance of automotive aluminium plate radiator  

Energy Technology Data Exchange (ETDEWEB)

The thermal performance of an automotive radiator plays an important role in the performance of an automobile's cooling system and all other associated systems. For a number of years, this component has been given little attention with very little changing in its manufacturing cost, operation and geometry. As opposed to the old tubular heat exchanger configurations used in automotive radiators, plate heat exchangers currently form the backbone of today's process industry with their advanced performance reaching levels the designers of tubular heat exchangers can only dream of. The aluminium roll-bonding technique widely used in manufacturing the cooling compartments for domestic refrigeration units is one of the cheapest methods for heat exchanger manufacturing. Using this technique, it is possible to ...

2005-06-01

111

Transmit-receive eddy current probes for heat exchanger inspection  

International Nuclear Information System (INIS)

This paper describes various eddy current probes, and their performance, which were developed at the Chalk River Laboratories of Atomic Energy of Canada. Included are probes for detecting defects at tubesheet regions in heat exchanger tubes, defects at expansion-transition regions in finned tubes, and defects in ferromagnetic tubes. All of these probes can be used with conventional commercially available instruments. (author).

1987-09-01

112

The sizing and passage arrangement of multistream plate-fin heat exchangers  

Energy Technology Data Exchange (ETDEWEB)

A simple and effective method is presented for the sizing and passage apportionment of multistream plate-fin heat exchangers. Methods for passage arrangement are discussed, and it is shown that a symmetric or mixed passage arrangement is more efficient than a segregated arrangement. A method for assessing the relative merits of various passage arrangements is presented. The use of the methods is illustrated through a worked example.

1996-07-01

113

Simultaneous absolute and differential operation of eddy current bobbin probes for heat exchanger tube inspection  

Energy Technology Data Exchange (ETDEWEB)

Here the authors try to dissolve some commonly held misconceptions about the operation of eddy current probes used for inspecting heat exchanger tubes. With the help of computer model results, the authors demonstrate that, for optimized operation, absolute/differential probes should be operated with coil current flowing in phase with another. This month's feature should be of interest to researchers as well as for NDT field personnel.

2000-05-01

114

Flow-induced vibration specifications for steam generators and liquid heat exchangers  

International Nuclear Information System (INIS)

It is desirable to avoid vibration problems by following appropriate guidelines and specifications at the design stage. Accordingly, design specifications were developed to prevent tube failures due to vibration in nuclear steam generators and liquid heat exchangers. These specifications are outlined in this report. (author). 14 refs., 2 figs.

1983-06-15

115

Corrosion resistant coatings for silicon carbide heat exchanger tubes: Topical report  

Energy Technology Data Exchange (ETDEWEB)

This heat exchanger is a critical step in the development of the Externally Fired Combined Cycle power system, a direct-coal combustion power plant (gas turbine). SiC is the only material with the needed resistance to creep, thermal shock, and oxidation; however a protective coating is needed. Ten candidate materials were identified: alumina-based materials, materials stable with SiO, and low expansion materials. An initial screening study should be performed.

1996-09-01

116

Two-phase flow patterns and frictional pressure gradients in a small, horizontal, rectangular channel  

Energy Technology Data Exchange (ETDEWEB)

Two-phase flow patterns and frictional pressure gradients in flow in small, rectangular channels are being studies as part of a larger research program addressing phase-change heat transfer of pure refrigerants and refrigerant mixtures in plate-fin heat exchangers. Small rectangular flow channels were selected as representative of plain fin geometries. The particular channel reported herein has dimensions of 19.05 {times} 3.18 mm. Adiabatic flows of air/water mixtures, with the flow channel horizontal and the channel exit at near-atmospheric conditions, were utilized in the experiments. Analysis and interpretation of the pressure data relative to observed flow pattern transitions led to an objective method for determining the plug/bubble-to-slug flow transition. This method, together with visual observations, supplemented with photographic data, was used to develop a flow pattern man. A comparison of ...

1990-05-01

117

Solvent effects on the solvation shell exchange kinetics  

Energy Technology Data Exchange (ETDEWEB)

Classical molecular dynamics simulations are carried out to investigate the salvation shell exchange kinetics of potassium ion in bulk water, chloroform, and carbon tetrachloride. The reactive flux method is used to compute the dissociation rates. The influence of the solvent on the reaction rates and kinetic properties of this exchange process will be discussed. Comparison will be also be made to the prediction of the Grote-Hynes theory.

1997-12-31

118

Corrosion behaviour of non-ferrous metals in sea water  

Energy Technology Data Exchange (ETDEWEB)

The most typical kinds of corrosion of brasses are selective corrosion (dezincification) and stress corrosion. Prevention against these kinds of corrosion lies in application of arsenic alloy addition and appropriate heat treatment removing internal stresses as well as in maintaining the arsenic and phosphorus contents on a proper level. The most typical corrosion of cupronickels is the local corrosion. Selective corrosion occurs less often and corrosion cracking caused by stress corrosion in sea water does not usually occur. Crevice corrosion is found especially in places of an heterogeneous oxidation of the surface under inorganic deposits or under bio-film. Common corrosive phenomena for brasses and cupronickels are the effects caused by sea water flow and most often the impingement attack. Alloy additions improve resistance to the action of intensive sea water flow but situation in this field ...

2004-07-01

119

Failure analysis report: Heat exchanger tubes geothermal binary power plant, Magma Electric Company, East Mesa, California  

Energy Technology Data Exchange (ETDEWEB)

Radian received twelve sections of heat exchanger tubing from the Magma Electric Company's 10MW(e) East Mesa binary geothermal power plant. Three tube sections were received from each of four shell and tube heat exchangers (HX1, Hx6, HX8, and Hx10) of the isobutane vaporizer train. All samples were taken from the upper few rows of tubes. Two months later, four more tube sections were received. These four sections were taken from the lower rows of heat exchangers 1, 6 (two sections), and 10. Radian was requested to investigate the cause of severe pitting failure of these heat exchanger tubes. This report is part of a continuing DOE effort to gain insight into the service life of component materials employed in geothermal energy utilization.

1982-05-01

120

Underground Mine Water Heating and Cooling Using Geothermal Heat Pump Systems  

Energy Technology Data Exchange (ETDEWEB)

In many regions of the world, flooded mines are a potentially cost-effective option for heating and cooling using geothermal heat pump systems. For example, a single coal seam in Pennsylvania, West Virginia, and Ohio contains 5.1 x 1012 L of water. The growing volume of water discharging from this one coal seam totals 380,000 L/min, which could theoretically heat and cool 20,000 homes. Using the water stored in the mines would conservatively extend this option to an order of magnitude more sites. Based on current energy prices, geothermal heat pump systems using mine water could reduce annual costs for heating by 67% and cooling by 50% over conventional methods (natural gas or heating oil and standard air conditioning).

2006-03-01

121

Integrated interpretation of AE clusters and fracture system in Hijiori HDR artificial reservoir; Hijiori koon gantai jinko choryuso no AE cluster to kiretsu system ni kansuru togoteki kaishaku  

Energy Technology Data Exchange (ETDEWEB)

With regard to a fracture system in the Hijiori hot dry rock artificial reservoir, an attempt was made on an interpretation which integrates different data. Major factors that characterize development and performance of an artificial reservoir are composed of a fracture system in rocks, which acts as circulating water paths, a heat exchange face and a reservoir space. The system relates not only with crack density distribution, but also with cracks activated by water pressure fracturing, cracks generating acoustic emission (AE), and cracks working as major flow paths, all of which are characterized by having respective behaviors and roles. Characteristics are shown on AE cluster distribution, crack distribution, production zone and estimated stress fields. Mutual relationship among these elements was discussed based on the Coulomb`s theory. The most important paths are characterized by distribution of ...

1997-05-27

122

High temperature heat transfer augmentation  

International Nuclear Information System (INIS)

The heat transfer augmentation is reviewed in view of high temperature heat exchangers illuminating the contribution of radiative heat transfer. A number of means and/or devices are presented as well as the sophisticated concept which will be promoted to the extended applications in matured industries such as iron and steel, oir refinery, petro-chemical. It should be emphasized that the more creative and innovatory technology has to be promoted in order to stimulate and refresh the foregoing industries, recognizing the increasing importance of the energy resources.

1985-08-01

123

Heat transfer augmentation by interrupted surfaces - Experimental considerations  

International Nuclear Information System (INIS)

An experimental study was undertaken to determine for the turbulent regime the heat transfer and fluid flow characteristics of a heat exchange array of unperforated, and perforated brass plates with 33% of the plate area open. In both cases, the plates were aligned parallel to the flow direction. For the flow conditions examined, the results showed enhancement of heat transfer and friction factor for the perforated array.

1987-08-01

124

Analysis of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For detector position out side ...

2005-11-23

125

Growth and gas exchange response to water shortage of a maize crop on different soil types  

British Library Electronic Table of Contents (United Kingdom)

The effect of water shortage on growth and gas exchange of maize grown on sandy soil (SS) and clay soil was studied. The lower soil water content in the SS during vegetative growth stages did not affect plant height, above-ground biomass, and leaf area index (LAI). LAI reduction was observed on the SS during the reproductive stage due to early leaf senescence. Canopy and leaf gas exchanges, measured by eddy correlation technique and by a portable photosynthetic system, respectively, were affected by water stress and a greater reduction in net photosynthetic rate (A N) and stomatal conductance (g s) was observed on SS. Chlorophyll and carotenoids content was not affected by water shortage in either condition. Results support two main conclusions: (1) leaf photosynthetic capacity was unaffec...

2009-01-01

126

Binary heat pump system. Binary heat pump system  

Energy Technology Data Exchange (ETDEWEB)

This technical report describes an outline, features, total energy efficiency, and specifications of binary heat pump system. A closed circuit distributed water heat source heat pump method is employed in the binary heat pump system. Since the circulating water, which is adjusted at a constant temperature, is used as the heat source of the indoor unit, a stable performance can be obtained regardless of outside atmospheric temperature. The binary heat pump system is mainly composed of a center heat pump unit, indoor heat pump unit, heat source water pipes, and circulating pump. The center heat pump unit and the indoor heat pump unit are connected with each other by the heat ...

1993-11-30

127

Geothermal heat pump applications: Industrial/commercial  

Energy Technology Data Exchange (ETDEWEB)

The fastest rate of growth in the space conditioning market has been attributed to the application of geothermal heat pumps to the industrial and commercial markets. The author reviews and provides examples of the three most popular components of a large geothermal heat pump system: geothermal earth coupling, heat pumps and heat exchangers, and building side terminals. These components are applied to three example geothermal installations: a library, an office building, and a school. Examples of energy use before and after the installation of a geothermal space conditioning system are summarized. General design and cost guidelines and comments on the use of geothermal heat pump in these and similar applications are discussed.

1999-07-01

128

Evaluation of heat exchange rate of GHE in geothermal heat pump systems  

Energy Technology Data Exchange (ETDEWEB)

Total thermal resistance of ground heat exchanger (GHE) is comprised of that of the soil and inside the borehole. The thermal resistance of soil can be calculated using the linear source theory and cylindrical source theory, while that inside the borehole is more complicated due to the integrated resistance of fluid convection, and the conduction through pipe and grout. Present study evaluates heat exchange rate per depth of GHE by calculating the total thermal resistance, and compares different methods to analyze their similarities and differences for engineering applications. The effects of seven separate factors, running time, shank spacing, depth of borehole, velocity in the pipe, thermal conductivity of grout, inlet temperature and soil type, on the thermal resistance and heat exchange rate are analyzed. Experimental data from several real geothermal ...

2009-12-15

129

The controllability analysis of the purification system for heavy water reactors  

International Nuclear Information System (INIS)

The heavy water reactor such as Wolsung No.1 and No.2 has a purification system to purify the reactor coolant. The control system regulates the coolant temperature to protect the ion exchanger. After the fuel exchanges of operating plant, the increase of the coolant pressure makes the purification temperature control difficult. In this paper, the controllability of the control dynamics of the purification system was analysed and the optimal parameters were proposed. To reduce the effects of the flow disturbance, the feedforward control structure was proposed and analysed.

2001-10-01

130

Heating and hot water: the installations; Chauffage et eau chaude: les installations  

Energy Technology Data Exchange (ETDEWEB)

This book brings recommendations and information on the choice and the operating of heating systems and domestic hot water production in order to better choose the house, to better use the heating and to preserve the environment. General notions on the different heating systems and their operating on the renewable energies used and the heating emitters offer advices for the purchase of a house. (A.L.B.)

2005-07-01

131

Heat transfer augmentation in a heat exchanger tube using a baffle  

International Nuclear Information System (INIS)

Heat transfer enhancement in a heat exchanger tube by installing a baffle is reported. The effect of baffle size and orientation on the heat transfer enhancement was studied in detail. Three different baffle arrangements were considered. The results show that for the vertical baffle, an increase in the baffle height causes a substantial increase in the Nusselt number but the pressure loss is also very significant. For the inclined baffles, the results show that the Nusselt number enhancement is almost independent of the baffle inclination angle, with the maximum and average Nusselt number 120% and 70% higher than that for the case of no baffle, respectively. For a given baffle geometry, the Nusselt number enhancement is increased by more than a factor of two as the Reynolds number decreased from 20,000 to 5000. Simulations were conducted by introducing another baffle to enhance heat ...

2007-04-01

132

Crud removal performance with ion exchange resins in BWR plants  

Energy Technology Data Exchange (ETDEWEB)

It is needless to say that one of the most important roles of the condensate demineralizer in Japanese boiling water reactors (BWR) is to eliminate such impurities during accidental occurrence of sea water leakage from condensate cooling system. Ion exchange resins packed in condensate demineralizer have also been expected to decrease crud, or corrosion products (CP) in condensate water in order to finally reduce activated corrosion products (ACP) in the reactor coolant loop. It is perceived that crud removal ability of a condensate demineralizer has been improved year by year. And we call this phenomenon as `Aging Effect`. Typical property changes of aged cation exchange resin consisted of an increase of water retention capacity and a change of surface texture. Based on these findings, we formulated a new concept and developed new gel type ion ...

1996-01-01

133

Rural residential application of geothermal heat pump. Progress report  

Energy Technology Data Exchange (ETDEWEB)

The installation and performance of a water source heat pump in Minnesota are discussed. The operating cost was found to be higher than expected. (MHR)

1981-07-20

134

Study on development of high performance evaporator for automotive air conditioner  

Energy Technology Data Exchange (ETDEWEB)

The object of the present study is to develop a high performance evaporator for automotive air conditioner. The experiment has been conducted on evaporative heat transfer coefficient inside a plate type heat exchanger with a sharp 180-degree turn flow. The test plates have different formed surface, cross-ribboned channel and elliptical-ribbed channel. Also experimental study has been performed to determine optimal design in elliptical-ribbed plate heat exchanger with different turn clearance. In addition to the above experiments, refrigerant behavior and surface temperature distribution in the plate heat exchanger were observed using color thermo viewer(infrared thermometer). In this experiment, working fluid was used R-12 and test conditions were as follows : (1) saturation pressure of 2,116 kg/cm{sup 2}, (2) mass fluxes of 40 to 70 ...

1995-02-01

135

Review of passive heat transfer augmentation techniques  

Energy Technology Data Exchange (ETDEWEB)

Heat transfer augmentation techniques (passive, active or a combination of passive and active methods) are commonly used in areas such as process industries, heating and cooling in evaporators, thermal power plants, air- conditioning equipment, refrigerators, radiators for space vehicles, automobiles, etc. Passive techniques, where inserts are used in the flow passage to augment the heat transfer rate, are advantageous compared with active techniques, because the insert manufacturing process is simple and these techniques can be easily employed in an existing heat exchanger. In design of compact heat exchangers, passive techniques of heat transfer augmentation can play an important role if a proper passive insert configuration can be selected according to the heat exchanger ...

2004-12-01

136

Pipe Freeze Prevention for Passive Solar Water Heaters Using a Room-Air Natural Convection Loop: Preprint  

Energy Technology Data Exchange (ETDEWEB)

Conference paper regarding research in the use of freeze prevention for passive solar domestic water heating systems.

2006-05-01

137

Field performance of an energy pile system for space heating  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the field performance of air conditioning with an energy pile system, which was applied to the pile foundations of an actual building for the purpose of reducing the cost of the underground heat exchanger. First, the building for both office and residential use, for which a space heating and cooling system using friction piles was installed, was built in Sapporo in December 2000. Second, three tests were carried out to specify the design of a heat exchanger inside the pile, and a U-tube type underground heat exchanger was adopted from the viewpoint of energy efficiency and installation costs. Long-term space heating operation measurements indicated that the seasonal average temperatures of brine returning from the underground and pile surfaces were 2.4 and 6.7 deg C, respectively. The average ...

2007-05-15

138

Analysis of laminar flow and heat transfer in the entrance region of an internally finned concentric circular annular duct  

Energy Technology Data Exchange (ETDEWEB)

The concentric circular annular duct is a common geometry in many fluid flow and heat transfer devices. For the purpose of heat transfer augmentation, fins are often employed in the annular region, and such finned ducts find wide application in compact heat exchangers (5, 6). The analysis of flow and heat transfer in this geometry is, therefore, quite important from an engineering standpoint. For fully developed conditions, the problem has already been analyzed (7-10). However, no results are available for the developing flow in the entrance region. It is with this latter problem that the present paper is concerned.

1987-05-01

139

Comparative resilience of soil and natural zeolite against adverse features of a municipal sewage. A preliminary investigation  

International Nuclear Information System (INIS)

A research was started aiming at evaluating the possible use of natural zeolites as exchange conditioners to improve and make durable the soil resilience against the adverse effects of the use of anomalous waters for irrigation purposes. This paper deals with a preliminary investigation on the comparative resilience of an Entisol with poor exchange properties and of a Neapolitan yellow tuff (NYT) sample against the adverse features of a dirty municipal sewage (DSW). Results showed that NYT treatment largely and significantly improved the poor soil exchange activity. In particular. NYT exchange sites selectively took up ammonium from DSW. As a consequence, ammonium was trapped, then protected against losses in the environment and, concurrently, exchangeable cations, such as K and Ca, were made free as plant nutrients. The results highlight the possible positive ...

140

Recovery of transplutonium elements from aqueous and water-ethanol solutions of sulfuric acid and their separation from other actinides  

Energy Technology Data Exchange (ETDEWEB)

The behavior of Am, Cm, Bk, Cf, Es, and other actinides, as well as Zr, on anion and cation exchangers in aqueous and water-ethanol solutions of sulfuric acid as a function of the various components of the solution has been investigated. It has been discovered that the presence of ethanol in sulfuric acid solutions causes an increase in the distribution coefficients both on cation exchangers and on anion exchangers. The possibility of the use of ion exchangers for the preconcentration and separation of transplutonium elements from U, Np, Pu, Zr, and other elements which form strong complexes with sulfate ions over a broad range of concentrations of sulfuric acid has been demonstrated.

1988-05-01

141

Heat transfer augmentation of mixed convection through vortex shedding from an inclined plate in a vertical channel containing heated blocks  

Energy Technology Data Exchange (ETDEWEB)

A numerical analysis is made of the unsteady flow and heat transfer characteristics of mixed convection in a vertical block-heated channel with and without installing an inclined plate above an upstream block. Parameter studies including the inclined plate angle, Reynolds number (ranging from 260 to 530), and Grashof number (in the range of 0--3,200,000) on heat transfer performance have been explored in detail. The results show that the installation of an inclined plate in the vertical block-heated channel can effectively augment the blocks` heat transfer performance in the channel. This can be applied to heat exchangers.

1998-02-06

142

Mechanisms of heat transfer augmentaiton around the stagnation point of an impinging air jet laden with solid particles. Report 1. ; Evaluation procedure of heat transfer augmentaion due to unsteady heat conduction between laden particles and heat transfer surface. Koki niso shototsu funryu no yodomiten kinbo ni okeru dennetsu sokushin kiko. 1. ; Ryushi eno chokusetsu sesshoku netsuido ni yoru dennetsu sokushin koka no bunri hoho  

Energy Technology Data Exchange (ETDEWEB)

Several heat transfer augmentation mechanisms contribute to the heat transfer augmentation around the stagnation point in the gas-solid two-phase impinging jet flow. Among those contributions, that of heat exchange was numerically analyzed and characteristically elucidated by the unsteady direct contact heat conduction at the time of impingement between the laden particles and heat transfer surface. In other words, if the contact time is short between the particles and heat transfer surface, the former is heated by heat stored in the latter as a heat capacity. In such a region, the heat quantity to be transferred to the particles changes by not only the thermal property value (heat capacity multiplied by heat ...

1991-05-25

143

Studies on improvement of heat transfer characteristics in high temperature heat exchangers, (1)  

International Nuclear Information System (INIS)

Reported in this paper are the theoretical and experimental studies, with regard to the effects of radiation between walls, conducted for the improvement of heat transfer characteristics of the circular duct in high temperature heat exchangers that operate through the medium of non-radiating gases at around 1,000"0C. To study the fundamental performance of the heat transfer augmentation, the experiment was carried out using a double tube at temperatures up to 900"0C. The outer tube in a double tube was selectively heated so as to give a uniform heat flux selected of 6.5 x 10"3 and 4.6 x 10"4 kcal/m"2.h, while the inner tube was used as a radiating surface to impart the radiation heat transmitted from the outer tube. Selectively preheated air was caused to flow in an annular passage at an inlet temperature selected within 100"0C to 400"0C and ...

1978-01-01

144

Recovering heat from the cupola stack  

Energy Technology Data Exchange (ETDEWEB)

A brief survey is given of some ways in which heat, which would normally be lost from a cupola furnace, is being recovered, either as hot water, steam, or electricity. Examples are provided of heat-recovery systems in Germany, Italy, and America. (author).

1986-01-01

145

Steam generator local water chemistry and SCC of austenitic steel  

Energy Technology Data Exchange (ETDEWEB)

The titanium stabilized austenitic steel similar to the type of 321 is sensitive to the stress corrosion crackingunder horizontal steam generator operating condition. SCC was observed under crevice corrosion parameters and has resulted in the transgranular or intergranular cracking at the both, components primary collectors and heat exchange tubes. The crevice environment is characterized by aggressive impurities and 'non aggressive' compounds. Sulfates and chlorides as aggressive species and silicates and alumino-silicates as 'non aggressive' species on the other hand are present in significant amount in the crevice environment under operating condition. Local water chemistry parameters were evaluated with MULTEQ Code. As input data the measured operational values of local and bulk environments have been used. The determined parameters were compared with the results of thread hole ...

1998-07-01

146

Simplified solar fraction estimation for space and water heating at dod installations. appendix c. water heating nomographs. Final report  

Energy Technology Data Exchange (ETDEWEB)

This report contains a set of nomographs which can be used to estimate the average annual solar fraction for solar space and water heating at a large number of DOD facilities. The solar fraction estimated from the nomograph is in close agreement with F-Chart 3.0 and allows for variation of the following parameters: annual load, collector area, collector transmittance-absorptance coefficient, and collector overall loss coefficient.

1982-09-01

147

Spacer grid effects on post-CHF heat transfer in an annulus geometry  

Energy Technology Data Exchange (ETDEWEB)

The term 'Post-CHF' was generally used in the two-phase flow regime in tube flow occurring downstream of the CHF. It has various other names such as dispersed flow, liquid-deficient flow, mist flow and film boiling because the two-phase regime is characterized by a continuous vapor phase with discrete liquid drops and a non-wetted heated surface. The regime has been adopted in a lot of applications including nuclear power plants, fossil power plants, steam generators, refrigeration systems and spray cooling, In particular, this regime has a considerable importance in the areas of light water reactor(LWR) accident analysis (off-normal operating conditions) and design in heat exchangers operating in the once-through mode where subcooled liquid enters the exchanger and superheated vapor exits. Recently, innovative PWRs adopt very high power density increases and so ...

2005-07-01

148

Spacer grid effects on post-CHF heat transfer in an annulus geometry  

International Nuclear Information System (INIS)

The term 'Post-CHF' was generally used in the two-phase flow regime in tube flow occurring downstream of the CHF. It has various other names such as dispersed flow, liquid-deficient flow, mist flow and film boiling because the two-phase regime is characterized by a continuous vapor phase with discrete liquid drops and a non-wetted heated surface. The regime has been adopted in a lot of applications including nuclear power plants, fossil power plants, steam generators, refrigeration systems and spray cooling, In particular, this regime has a considerable importance in the areas of light water reactor(LWR) accident analysis (off-normal operating conditions) and design in heat exchangers operating in the once-through mode where subcooled liquid enters the exchanger and superheated vapor exits. Recently, innovative PWRs adopt very high power density increases and so require increased ...

2005-05-26

149

Geothermal heat pump  

Energy Technology Data Exchange (ETDEWEB)

Ground water ranging in temperature from only 38/sup 0/ to 140/sup 0/F can supply a considerable amount of heat energy when couple with a geothermal or ground-water heat pump. The heat pump's method of operation is examined as well as its performance characteristics. (MHR)

1982-12-01

150

The Argonne boundary layer experiments facility : using minisodars to complement a wind profiler network.  

Energy Technology Data Exchange (ETDEWEB)

The Argonne Boundary Layer Experiments (ABLE) facility, located in south central Kansas, east of Wichita, is devoted primarily to investigations of and within the planetary boundary layer (PBL), including the dynamics of the mixed layer during both day and night; effects of varying land use and land form; the interactive role of precipitation, runoff, and soil moisture; storm development; and energy budgets on scales of 10 to 100 km. Located entirely within the Walnut River watershed, ABLE provides intense measurements within the northeast quadrant (Fig. 1) of the Southern Great Plains (SGP) Cloud and Radiation Testbed (CART) of the Atmospheric Radiation Measurement (ARM) Program (Stokes and Schwarz, 1994). By combining the continuous measurements of ABLE with ancillary continuous measurements of, for example, the ARM and the Global Energy Water cycle Experiment (GEWEX) (Kinster and Shukla, 1990) programs, ABLE provides a platform within which shorter, more ...

1998-06-05

151

Obstacle-induced perturbations on turbulent quantities measured in airflows over the sea  

Energy Technology Data Exchange (ETDEWEB)

An experimental campaign, aiming to investigate the perturbation effects induced by fixed obstacles on turbulence measurements in airflows at the air-sea interface, was carried out at the marine platform of the Italian Navy, located in the harbour of La Spezia (North Ligurian Sea, Italy) on 28., 29., and 30. June 1994. This study was prompted by the ever-growing interest in more reliable estimates of energy, mass, and momentum exchanges between water surfaces and atmosphere, whose measurements are severely limited by the geometrical constraints of floating or fixed platforms where they are installed. Two types of meteorological instruments have been used: fast response (20 and 21 Hz) ultrasonic anemometers and fluxmeters to measure turbulent momentum, sensible, and latent heat fluxes and slow-response sensors (less than 4 Hz and sampled at a rate of 10{sup 2} Hz) to measure average wind and temperature vertical profiles in ...

1998-07-01

152

Mesoporous activated carbons with metal-oxide particles prepared from Morwell coal; Morwell tan wo genryo to shita kinzoku sankabutsu tanji kasseitan no saiko kozo  

Energy Technology Data Exchange (ETDEWEB)

The metal dependence of mesoporous activated carbons with various metal acetylacetonate (acac) particles prepared from Morwell coal was studied. In experiment, the mixture of Morwell coal and acac metal complexes were dissipated into tetrahydrofuran, and after agitation in Ar atmosphere, the solvent was removed by vacuum distillation. Coal specimens with Fe(acac)3, Ni(acac)2 and Co(acac)2 as acac complexes were activated by exchanging flow gas with water vapor after heat treatment in N2 gas flow at 900{degree}C. The pore sizes of the specimens were obtained from N2 adsorption isotherms by BET method and BJH method. Conditions of pores and metals in the specimens were examined by XRD measurement and TEM observation. The relation between the above conditions and pore characteristics obtained from adsorption experiment was also examined. As a result, the difference in mesopore ratio between the specimens and blank specimens ...

1996-10-28

153

A calculation model for thermo-hydraulic analyses of the PGV-1000 steam generator  

International Nuclear Information System (INIS)

A calculation model was developed for the analysis of thermal and hydraulic processes in the PGV-1000 horizontal steam generator. The model makes it possible to examine the hydraulics of the primary medium, i.e., the distribution of flow velocities and mass flows in the exchanger tube system and hydraulic losses of the primary medium in the steam generator during its flow between the two connecting sites to the main circulation pipeline, spatial distribution of heat fluxes between the primary and secondary sides of the steam generator and the total transmitted thermal power, pressure on the secondary side of the generator, natural circulation of the working medium on the secondary side, and the mean circulation number, spatial distribution of the volume fraction of the steam component in the intertubular space, effect of the perforated sheet on the thermo-hydraulic processes in the steam generator, redistribution of the steam component in the ...

1994-01-01

154

The onset conditions of enhancement of ice accumulation associated with heat-conducting plates located perpendicularly to heat-transfer surfaces; Part 1: Analysis for still water  

Energy Technology Data Exchange (ETDEWEB)

An analytical study of the ice-formation process associated with heat-conducting plates located perpendicularly to isothermally heated and cooled surfaces with some clearance is presented. It is proposed that the onset conditions, which describe whether the ice-volume fraction in a steady state is greater than or less than that without heat-conducting plates, are defined by the dimensionless distances between the heated/cooled walls and the heat-conducting plates. It is shown that the onset conditions are dependent on the pitch and the thickness of the heat-conducting plates and are less dependent on the thermal conductivity of the plates.

1994-07-01

155

Geothermal Heat Pump research and development studies at Sandia National Laboratories  

Energy Technology Data Exchange (ETDEWEB)

The Geothermal Heat Pump (GHP) concept was originally developed in the 1940`s. Recently, because of increasing energy costs, utility interest, and the development of simple and durable ground source heat exchangers, GHP`s have gained international attention as a proven means of energy conservation and electrical peak power demand reduction. GHP systems require installation of a buried heat exchanger to utilize the nearly constant ground temperature making them more efficient than conventional air source heat pumps. However, the high installation cost for both residential and commercial applications is a major obstacle to their market penetration. Sandia National Laboratories (SNL) through its sponsors, the Department of Energy (DOE), and the Department of Defense (DOD), has embarked on a research program to find ways to reduce GHP installation costs and improve ...

1994-08-01

156

The feasibility of using a septic tank as a heat source for geothermal heat pumps  

Energy Technology Data Exchange (ETDEWEB)

A geothermal heat pump (GHP) system with three ground coils was installed in a residence in northern Idaho with a portion of the ground heat exchanger wrapped around the residential septic tank. The septic coil provided a significant portion of the heating for the residence over the heating season. There was no evidence of the septic tank freezing up or failing to properly function. Utilizing a septic tank as a heat source for GHP systems is feasible design option if the septic tank is used on a full-time basis. However, the tank should be surrounded on all sides by a large amount of soil and/or insulated from the ground surface to ensure that ground temperatures near the tank remain warm during the winter.

1999-11-01

157

Basic study on heat transfer characteristics of liquid Na in a decay-heat removal system of LMFBR  

Energy Technology Data Exchange (ETDEWEB)

A numerical analysis is performed to clarify the heat transfer characteristics of combined convection around the tubes which form a single row perpendicularly arranged to a forced flow in the direction of gravity. A boundary-fitted coordinate transformation technique is adopted to solve the governing equations numerically. It is found in the case of liquid sodium that gravity-induced flow gives no substantial effect to heat transfer augmentation in a low Reynolds number region while it can be sufficiently expected in the ordinary fluids in the same Reynolds number region. This means that such heat transfer augmentation as expected in ordinary fluids can not be realized when crossflow-type heat exchangers installed for decay-heat removal operates in a low Reynolds number region.

1988-02-01

158

A basic study on heat transfer characteristics of liquid Na in a decay-heat removal system of LMFBR  

International Nuclear Information System (INIS)

A numerical analysis is performed to clarify the heat transfer characteristics of combined convection around the tubes which form a single row perpendicularly arranged to a forced flow in the direction of gravity. A boundary-fitted coordinate transformation technique is adopted to solve the governing equations numerically. It is found in the case of liquid sodium that gravity-induced flow gives no substantial effect to heat transfer augmentation in a low Reynolds number region while it can be sufficiently expected in the ordinary fluids in the same Reynolds number region. This means that such heat transfer augmentation as expected in ordinary fluids can not be realized when crossflow-type heat exchangers installed for decay-heat removal operates in a low Reynolds number region. (author).

1988-01-01

159

On the water-chemical regime in steam generators at NPP  

British Library Electronic Table of Contents (United Kingdom)

The effect of the water-chemical regime (WCR) on damage sustained by heating surfaces of steam generators at NPP is analyzed. It is indicated that phosphate treatment with minimal excesses of phosphates in the steamgenerator water is the most optimal method of managing the WCR regime of horizontal steam generators.

2006-01-01

160

Heat-transfer analysis of the plum brook reactor - NASA Technical ...  

Science.gov (United States)

average bulk water temper ature rise, OF bulk water temperature at elevation z, OF bulk water temperature in channels 0 and 1, O F film temperature, OF ...

161

Condensation heat transfer in a steam-water stratified flow  

Energy Technology Data Exchange (ETDEWEB)

Fundamental phenomena of condensation heat transfer at a steam-water interface have been studied related to the thermo-hydrodynamics of the emergency core cooling system for light water reactors. In this study temperature fluctuations near the interface and in the liquid phase were measured using fine thermocouples for a saturated steam-subcooled water co-current stratified two-phase flow in a nearly horizontal rectangular channel, and heat transfer coefficients were determined experimentally. The values of the condensation heat transfer coefficients in this experiment are from 6 to 40 kW/m{sup 2}K. In the regions of high Reynolds numbers, as the steam Reynolds numbers become larger, the average interfacial heat transfer coefficients tend to increase. The corelations of Nusselt numbers were obtained from the heat ...

1999-07-01

162

Condensation heat transfer in a steam-water stratified flow  

International Nuclear Information System (INIS)

Fundamental phenomena of condensation heat transfer at a steam-water interface have been studied related to the thermo-hydrodynamics of the emergency core cooling system for light water reactors. In this study temperature fluctuations near the interface and in the liquid phase were measured using fine thermocouples for a saturated steam-subcooled water co-current stratified two-phase flow in a nearly horizontal rectangular channel, and heat transfer coefficients were determined experimentally. The values of the condensation heat transfer coefficients in this experiment are from 6 to 40 kW/m"2K. In the regions of high Reynolds numbers, as the steam Reynolds numbers become larger, the average interfacial heat transfer coefficients tend to increase. The corelations of Nusselt numbers were obtained from the heat transfer ...

1999-04-19

163

Boiling heat transfer of subcooled water in a horizontal rectangular channel. Observation of MEB and MEB generation; Kukeikan ryuronai no subcool futto netsu dentatsu. Kiho bisaika futto no kansatsu to hassei joken  

Energy Technology Data Exchange (ETDEWEB)

Forced convection boiling of subcooled water was performed in a horizontal rectangular channel with heated surface on the bottom. The experiment was conducted for heating surfaces, 10 mm, 20 mm and 40mm in length. Microbubble Emission Boiling, MEB, was observed in subcooled transition boiling and easy to be generated for the shorter heating surfaces. In higher flow velocity of subcooled water, MEB was generated at even lower subcooling. Stormy MEB was observed at both the higher subcooling and the higher flow velocity of water. In the stormy MEB, the heat flux rose up rapidly above CHF (Critical Heat Flux) with larger acoustic noise and vibration. (author)

1999-09-25

164

Performance evaluation of a vortex generator heat transfer surface and comparison with different high performance surfaces  

International Nuclear Information System (INIS)

A comparative assessment of five different heat transfer configurations for operation in compact heat exchangers is presented. The configurations under consideration are four standaed heat exchanger surfaces - two plain fin, an offset strip and a louvered fin geometry - and one surface with so called vortex generators for heat transfer augmentation. In the case of the standard surfaces, the basic performance characteristics in the form of heat transfer and friction data versus the Reynolds number have been taken from published experimental results. In the case of the vortex generator surface, the performance characteristics have been derived from a numerical prediction of the flow and temperature field in a closely spaced parallel plate channel with vortex generators in the form of delta wings mounted on the channel walls. In comparison to ...

1993-01-01

165

Design of a closed 4 MW spallation target module with heat removal system for an ADS system  

International Nuclear Information System (INIS)

At the Forschungszentrum Karlsruhe the HGF Strategy Fund project entitled 'Innovative Technology to Reduce Radiotoxicity' is performed which delivers an essential scientific contribution to the application oriented fundamental research for Accelerator Driven Systems (ADS). The addressed topics are in the areas of heavy liquid metal technology, thermalhydraulics and materials / corrosion. An ADS consists of three main components: an proton accelerator, a spallation target and a subcritical blanket. The strategic objective of an ADS is the transmutation of long-lived radioactive waste (plutonium, minor actinides and long-lived fission products) into short-lived isotopes or stable elements, thus closing the fuel cycle. The objective of one task of the HGF Strategy Fund Project is the numerical calculation of a closed spallation target module. In a consequent next step such a spallation target can be experimentally investigated at IKET and the numerical results can be validated. In this ...

166

Electrodeless, multi-megawatt reactor for room-temperature, lithium-6/deuterium nuclear reactions  

International Nuclear Information System (INIS)

This paper describes a reactor design to facilitate a room-temperature nuclear fusion/fission reaction to generate heat without generating unwanted neutrons, gamma rays, tritium, or other radioactive products. The room-temperature fusion/fission reaction involves the sequential triggering of billions of single-molecule, "6LiD 'fusion energy pellets' distributed in lattices of a palladium ion accumulator that also acts as a catalyst to produce the molecules of "6LiD from a solution comprising D_2O, "6LiOD with D_2 gas bubbling through it. The D_2 gas is the source of the negative deuterium ions in the "6LiD molecules. The next step is to trigger a first nuclear fusion/fission reaction of some of the "6LiD molecules, according to the well-known nuclear reaction: "6Li + D #-># 2"4He + 22.4 MeV. The highly energetic alpha particles ("4He nuclei) generated by this nuclear reaction within the palladium will cause shock and vibrations in the palladium lattices, leading ...

167

A study of binary mixture boiling: boiling site density and subcooled heat transfer  

Energy Technology Data Exchange (ETDEWEB)

(Boiling site densities and heat-transfer coefficients have been measured for ethanol-water and ethanol-benzene mixtures at 1.01 bar for a heated vertical brass disk. A strong effect of composition on the boiling site density was observed, which was attributed to the nature of the activation of the boiling surface and mass diffusion effects. The boiling heat-transfer coefficient was found to decrease with increasin subcooling, but for the mixtures at a given level of subcooling the decrease was less than that for the single components and azeotropic mixtures.) The heat-transfer coefficient at a given heat flux was seen to be quite insensitive to the very large increase in boiling site density in comparing the pure water and the ethanol-water azeotrope results, leading one to question pool boiling models that predict ...

1985-05-01

168

Residential vertical geothermal heat pump system models: Calibration to data  

Energy Technology Data Exchange (ETDEWEB)

A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was tuned to better match the measured data from the site. These tuned models were then interconnected to form the system model. The system model was then exercised in order to demonstrate its capabilities.

1997-12-31

169

Residential Vertical Geothermal Heat Pump System Models: Calibration to Data:  

Energy Technology Data Exchange (ETDEWEB)

A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was 'tuned' to better match the measured data from the site. These tuned models were then interconnect to form the system model. The system model was then exercised in order to demonatrate its capabilities.

1997-06-01

170

Gas-fired boiler plant  

Energy Technology Data Exchange (ETDEWEB)

A gas-fired boiler plant comprises a burner bed extending over a flat surface and heat exchanger pipes arranged above the burner bed, parallel to the said surface. The heat exchanger tubes comprise pipes equipped with a pluraltiy of flat ribs which extend substantially radially from the said pipes and which are provided in space arrangement over the length of the said heat exchanger pipes. The ribs are provided with bent-off portions. The hot flue gases rising from the burner bed flow through the gaps formed between the said ribs and pipes. In order to improve both the convective heat transmission and the utilization of the radiant heat, the bent-over edges are inclined, at least partly, relative to the surface of said burner bed, the arrangement being selected in a manner to ensure that bent-over portions point towards ...

1989-10-10

171

A mathematical model for simulating shallow solar ponds for treatment of industrial wastewater  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a mathematical model to analyze the solar evaporation in a shallow pond in steady state, when the inlet flow rate, concentration, surface area and solar radiation are given. The simultaneous heat and mass transfer mechanisms are considered for quantifying the amount of evaporated water to the atmosphere and the actual absorbed heat by wastewater is calculated to obtain the bottom temperature of water pond. The heat losses to air by radiation and convection mechanisms are considered and the heat transmission across the water film is evaluated by the forced convection mechanism. 6 refs., 5 figs., 1 tab.

1996-12-31

172

Liquid Water from First Principles: Validation of Different Sampling Approaches  

Energy Technology Data Exchange (ETDEWEB)

A series of first principles molecular dynamics and Monte Carlo simulations were carried out for liquid water to assess the validity and reproducibility of different sampling approaches. These simulations include Car-Parrinello molecular dynamics simulations using the program CPMD with different values of the fictitious electron mass in the microcanonical and canonical ensembles, Born-Oppenheimer molecular dynamics using the programs CPMD and CP2K in the microcanonical ensemble, and Metropolis Monte Carlo using CP2K in the canonical ensemble. With the exception of one simulation for 128 water molecules, all other simulations were carried out for systems consisting of 64 molecules. It is found that the structural and thermodynamic properties of these simulations are in excellent agreement with each other as long as adiabatic sampling is maintained in the Car-Parrinello molecular dynamics simulations either by choosing a sufficiently small ...

2004-05-20

173

The Blood-Brain Barrier and Microvascular Water Exchange in Alzheimer's Disease  

UK PubMed Central (United Kingdom)

Alzheimer's disease (AD) is the most common form of dementia in the elderly. Although traditionally considered a disease of neurofibrillary tangles and amyloid plaques, structural and functional changes...Full Text Available

2011-01-01

174

Development of Tritium Removal Technology.  

Science.gov (United States)

Liquid Phase Catalytic Exchange (LPCE)- Cryogenic Distillation(CD) process was studied which could be available for an optimal tritium removal process of pressurized heavy water reactor system at Wolsung nuclear power plant in the near future. Based upon ...

1986-01-01

175

Water management studies in PEM fuel cells, part III: Dynamic breakthrough and intermittent drainage characteristics from GDLs with and without MPLs  

British Library Electronic Table of Contents (United Kingdom)

The transport of liquid water and gaseous reactants through a gas diffusion layer (GDL) is one of the most important water management issues in a proton exchange membrane fuel cell (PEMFC). In this work, the liquid water breakthrough dynamics, characterized by the capillary pressure and water saturation, across GDLs with and without a microporous layer (MPL) are studied in an ex-situ setup which closely simulates a real fuel cell configuration and operating conditions. The results reveal that recurrent breakthroughs are observed for all of the GDL samples tested, indicating the presence of an intermittent water drainage mechanism in the GDL. This is accounted for by the breakdown and redevelopment of the continuous water paths during water drainage as demonstrated by Haines jumps. For GDL ...

2010-01-01

176

Fundamental study on the convective heat transfer augmentation of a wavy type heat exchanger  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the study is to investigate the heat transfer augmentation method for a wavy channel type heat exchanger. Experimental studies were carried out, by installation of flow guide-plates with simple structure, to clarify the effects on the augmentation whether the effects are brought by the flow acceleration or by the increase of intensity of turbulence due to the flow seperation, and to determine optimum shape of flow guide-plates. The shape and dimensions of the experimental apparatus are as follows; channel width H of 30 mm, rectangular section with breadth of 300 mm, wavy duct with a bend angle of 60/sup 0/ and straight pipe of 2H length. Air stream was flowed through the duct with Reynolds number of 1.7 x 10/sup 4/ only. As the results, following conclusions were obtained. (1) Wavy duct with large bend angle and without inserting flow guide-plates could not be expected large effects on the ...

1988-06-25

177

Experimental study and performance evaluation of convective heat transfer augmentation with coiled wire inserts  

Energy Technology Data Exchange (ETDEWEB)

An experimental study of forced convection heat transfer at the inner tube wall of a double pipe heat exchanger with coiled wire inserts as heat transfer augmentation devices was performed over a turbulent flow region. The test results from twelve augmented tubes with inserts of different combinations of wire diameters (0.813, 1.016 and 1.575 mm) and pitches (2.82, 3.63, 5.08 and 8.47 mm) indicate that the turbulence promoters studied improve heat transfer by a factor of 1.4 to 2.24 compared with a smooth tube, although at a cost of 10-30 times increase in friction factor. A formula for presenting dimensionless exergy losses in a tubular heat exchanger is derived first and then the thermohydrodynamic optimum instead of economic optimum is found by minimizing the exergy losses in the system. From the heat transfer ...

1992-12-01

178

Fractionation of isotopes of alkali metals and alkaline earth metals in ion exchange chromatography  

International Nuclear Information System (INIS)

Fractionation of isotopes of the alkali metals and the alkaline earth metals in ion exchange chromatography of their chlorides was studied. The heavier isotopes of potassium and rubidium were found to be preferentially fractionated into the ion exchanger phase while the lighter isotopes of lithium, magnesium, calcium and strontium were enriched in the exchanger phase. This can be interpreted as a resultant of the relative significance of isotope effect upon dehydration and isotope effect accompanying the phase change of the hydrated metal ion. Found was no evidence of anomalous isotope effect attributable to the odd-even difference in mass number of isotopes. Based on the spectroscopic and solution chemical data (experimental and theoretical), the isotopic reduced partition function ratios of the hydrated alkaline metal ions and stretching force constants of metal ion-hydrating water bonds were ...

179

Application of Combined Enhanced Techniques for Design of Highly Efficient Air Heat Transfer Surface  

British Library Electronic Table of Contents (United Kingdom)

In order to reduce the size and cost of heat exchangers, an air-side wavy fin-and-tube heat transfer surface with three-row tubes needs to be replaced by two-row tubes with some appropriate enhancing techniques. The major purpose of the present paper is to search for such new structure by numerical simulation. First, longitudinal vortex generators of Delta-winglet type are tried. The influence of number and of arrangement of the winglets on the performance of the heat transfer surface is studied in detail. The numerical results show that the fin with two winglets aligned spanwise in the front and rear of each tube (Fin W6) has higher heat transfer capability than other enhanced structures with vortex generators, but it still unable to meet the heat transfer requirement. Then a combination ...

2012-01-01

180

Matching of water and temperature fields in proton exchange membrane fuel cells with non-uniform distributions  

British Library Electronic Table of Contents (United Kingdom)

In this work, a three-dimensional multiphase non-isothermal model incorporated with a capillary-extended sub-model in gas channels is used to investigate the coupled phenomena of water and thermal transport in proton exchange membrane fuel cells. Distributions of water and temperature along the flow path in the channel are highlighted and the pros and cons of various operating temperatures are elaborated. In addition, this work also sheds light on the impacts of temperature variations of bipolar plates induced by non-uniform cooling conditions, which have been overlooked by most previous works. An important phenomenon of water distribution, dry-out at inlets and flooding at outlets (DIFO), is observed and this non-uniform distribution is revealed to be greatly influenced by the operating t...

2011-01-01

181

Electrochemistry Modeling of Proton Exchange Membrane (PEM) Water Electrolysis for Hydrogen Production  

International Nuclear Information System (INIS)

An electrochemistry model was developed to analyse the J-V characteristics of a Proton Exchange Membrane (PEM) water electrolyzer for hydrogen production. The Butler-Volmer equation and water transport characteristics through electrolyte membrane were employed to simulate the electrode activation over-potential and membrane ohmic over-potential, respectively. The modeling results are found to agree reasonably well with experimental data published in the literature. The parametric simulations show that the ohmic over-potential is relatively small with typical water content in the membrane. Compared with the cathode over-potential, the anode over-potential is more significant and constitutes the major source of voltage loss. The high anode over-potential is due to the relatively slow oxidation kinetics, which is related to anode material property and microstructure. This model can be integrated with a ...

2006-06-13

182

Steam generator PGV-1000 thermal-hydraulics  

International Nuclear Information System (INIS)

The main features are presented of a computer programme for 3-D thermohydraulic and thermodynamic analysis of the PGV-1000 horizontal steam generator used at the Temelin NPP. The programme provides analyses of primary side hydraulics, heat exchange behavior and the steam generator secondary side thermohydraulics and thermodynamics. Given are calculated data on the circulation flow rate, void fraction, heat transfer dynamics and the swelled level. (Z.S.) 9 figs.

1995-09-21

183

Heat exchange in a multi-cavity volumetric solar receiver  

Energy Technology Data Exchange (ETDEWEB)

The concept of a multi-cavity volumetric solar receiver is very attractive for the profitability of certain of its characteristics such as high efficiency and economy. The absorber is based on a pack of small ceramic cavities which intercept and absorb the inherent high solar flux reflected from an array of mirrors. Atmospheric air acts as a coolant medium when it is drawn through the pack. A model for an overall heat transfer performance of the receiver is given and numerically solved.

1991-01-01

184

Simplified solar fraction estimation for space and water heating at DOD installations. appendix b. space heating nomographs. Final report  

Energy Technology Data Exchange (ETDEWEB)

A set of nomographs is presented which can be used to estimate the average annual solar fraction for solar space and water heating at a large number of DOD facilities. The solar fraction estimated from the nomograph is in close agreement with F-Chart 3.0 and allows for variation of the following parameters: annual load, collector area, collector transmittance-absorptance coefficient, and collector overall loss coefficient.

1982-09-01

185

Rural residential application of geothermal heat pump. Final grant report  

Energy Technology Data Exchange (ETDEWEB)

A project to demonstrate residential heating and cooling with a well-water source heat pump is documented. The system is schematically illustrated and described, and project experience is discussed. The system is capable of using source water as cool as 40/sup 0/F. Project expenses are accounted for. (LEW)

1982-07-30

186

Effect of ultrasonic waves on boiling heat transfer. 2  

International Nuclear Information System (INIS)

This report focuses on a better understanding of the physical phenomenon related to the enhancement of boiling and non-boiling heat transfer by applying ultrasonic waves. Experimental results obtained both in a pool of water and in a vertically upward water flow proved clearly that macroscopic acoustic steam induced by ultrasonics is a major contribution to heat transfer augmentation. (author).

1993-05-01

187

Effect of ultrasonic waves on boiling heat transfer  

Energy Technology Data Exchange (ETDEWEB)

This report focuses on a better understanding of the physical phenomenon related to the enhancement of boiling and non-boiling heat transfer by applying ultrasonic waves. Experimental results obtained both in a pool of water and in a vertically upward water flow proved clearly that macroscopic acoustic stream induced by ultrasonics is a major contribution to heat transfer augmentation. (author).

1993-07-01

188

Ventilation as a means of air-conditioning power saving in reinforced concrete telephone-exchange buildings analysis and directions for design  

Energy Technology Data Exchange (ETDEWEB)

The paper presents a computer-aided analysis of the combined use of ventilation and structural heat capacity and insulation as a means of saving air-conditioning power in digital telephone exchanges. It is shown that such savings can be effected by increasing air change with outdoor cool air at night, and when feasible, also in daytime, through the air change unit, in a conventional airconditioning cycle. The total thermal time constant (TTTC) method of calculation used enables the evaluation of daily or seasonal heat-flow balance for a given indoor temperature, considering the tendency of the heat capacity of the building and of envelope components to flatten the fluctuations of this temperature.

1984-12-01

189

Status of non-electric nuclear heat applications: Technology and safety  

International Nuclear Information System (INIS)

Nuclear energy plays an important role in electricity generation, producing 16% of the world's electricity at the beginning of 1999. It has proven to be safe, reliable, economical and has only a minimal impact on the environment. Most of the world's energy consumption, however, is in the form of heat. The market potential for nuclear heat was recognized early. Some of the first reactors were used for heat supply, e.g. Calder Hall (United Kingdom), Obninsk (Russian Federation), and Agesta (Sweden). Now, over 60 reactors are supplying heat for district heating, industrial processes and seawater desalination. But the nuclear option could be better deployed if it would provide a larger share of the heat market. In particular, seawater desalination using nuclear heat is of increasing interest to some IAEA Member States. In consideration of the ...

190

Equipment for a central heating system with expansion tank, pressure control, water loss supply, de-aeration, recording and control; Apparaat t.b.v. C.V.-installatie met expansievat, drukregeling, waterverliessuppletie, ontluchting, registratie en controle  

Energy Technology Data Exchange (ETDEWEB)

The very low-pressure expansion tank of the title invention is connected to the water in the central heating installation via a connecting pipe with a pump and valves on one side, and on the other side the tank is connected via a connecting pipe with valve to the tap water mains, so that the supply of water can be regulated automatically. Within the expansion tank contact with the outside air is not possible because of an air/water separating floater. By means of recording and control (also remote) of the contents of the expansion tank, the installation pressure and the quantity of supplied water from the expansion tank and the tap water mains, failures and water damage are prevented. 4 figs.

1995-09-01

191

Characterisation of a re-cast composite Nafion 1100 series of proton exchange membranes incorporating inert inorganic oxide particles  

International Nuclear Information System (INIS)

A series of cation exchange membranes was produced by impregnating and coating both sides of a quartz web with a Nafion solution (1100 EW, 10%wt in water). Inert filler particles (SiO_2, ZrO_2 or TiO_2; 5-20%wt) were incorporated into the aqueous Nafion solution to produce robust, composite membranes. Ion-exchange capacity/equivalent weight, water take-up, thickness change on hydration and ionic and electrical conductivity were measured in 1 mol dm"-"3 sulfuric acid at 298 K. The TiO_2 filler significantly impacted on these properties, producing higher water take-up and increased conductivity. Such membranes may be beneficial for proton exchange membrane (PEM) fuel cell operation at low humidification. The PEM fuel cell performance of the composite membranes containing SiO_2 fillers was examined in a Ballard Mark 5E unit cell. While the use of composite ...

2010-09-01

192

Uptake of atmospheric tritium by market foods  

Energy Technology Data Exchange (ETDEWEB)

In this paper uptake of tritium by market foods from tritiated water vapor in the air is investigated using cereals and beans purchased in Deep River, Canada. The concentrations of tissue free water tritium (TFWT) and organically bound tritium (OBT) range from 12 to 79% and from 10 to 38% respectively, of that estimated for atmospheric water vapor of the sampling month. The specific activity ratios of OBT to TFWT were constant for cereals, but variable for beans. The elevated OBT was shown to be the result of isotopic exchange of labile hydrogen by the fact that washing the foods with tritium free-water reduced their tritium contents to levels characteristic of their production sites.

1992-03-01

193

Numerical heat transfer studies of PCMs used in a box-type solar cooker  

Energy Technology Data Exchange (ETDEWEB)

Theoretical investigations on the phase change materials (PCMs) used as the heat storage media for box-type solar cookers have been conducted in this study. The selected PCMs are magnesium nitrate hexahydrate, stearic acid, acetamide, acetanilide and erythritol. For a two-dimensional simulation model based on the enthalpy approach, calculations have been made for the melt fraction with conduction only. Different materials such as glass, stainless steel, tin, aluminum mixed, aluminum and copper are used as the heat exchanger container materials in the numerical calculations. The large value of thermal conductivity of heat exchanger container material did not make a significant contribution on the melt fraction except for at very low thermal conductivities. Based on the theoretical results, stearic acid and acetamide are found to be good compatibility with latent ...

2008-05-15

194

Final phase testing and evaluation of the 500 kW direct contact pilot plant at East Mesa  

Energy Technology Data Exchange (ETDEWEB)

The testing performed during the last phase of the geothermal direct contact heat exchanger program utilizing the 500 kW pilot plant provided more insight into the capabilities and limits of the direct contact approach and showed that more work needs to be done to understand the inner workings of a large direct contact heat exchanger if they are to be modeled analytically. Testing of the column demonstrated that the performance was excellent and that the sizing criteria is conservative. The system operated smoothly and was readily controlled over a wide range of operating conditions. Performance evaluation showed pinch differentials of 4/sup 0/F or less and better than predicted heat transfer capability. Testing during this final phase was directed towards establishing the limits of the column to transfer heat. The working column height was shortened ...

1983-12-01

195

Review of Cardiff telephone exchange total energy system after three years operation  

Energy Technology Data Exchange (ETDEWEB)

A self contained continuous power generation system as described at INTELEC 1979, was successfully commissioned and put into service in a major communications centre at Cardiff in Wales. The objective was to provide all telecommunications equipment and electrical building engineering services from a dual fuel enginegenerating plant, and to recover waste heat energy to heat or cool the building. The plant, which is fully automatic, comprises five 1300kW engines using natural gas or diesel oil, and associated waste heat boiler and chiller systems. This paper reviews the functioning of the plant during its first three years of operation.

1983-10-01

196

Hydrothermal coupling in a rough fracture  

CERN Document Server

Heat exchange during laminar flow is studied at the fracture scale on the basis of the Stokes equation. We used a synthetic aperture model (a self-affine model) that has been shown to be a realistic geometrical description of the fracture morphology. We developed a numerical modelling using a finite difference scheme of the hydrodynamic flow and its coupling with an advection/conduction description of the fluid heat. As a first step, temperature within the surrounding rock is supposed to be constant. Influence of the fracture roughness on the heat flux through the wall, is estimated and a thermalization length is shown to emerge. Implications for the Soultz-sous-For\\^{e}ts geothermal project are discussed.

2006-01-01

197

An experimental integrated absorption heat pump effluent purification system. Pt. 1: Operating on water/lithium bromide solutions  

Energy Technology Data Exchange (ETDEWEB)

The merits of single stage absorption heat pumps coupled to simple distillation for effluent treatment are discussed. An experimental integrated absorption heat pump effluent purification system (IAHPEPS) was built and operated with water-lithium bromide as a working mixture. This unit has been used to raise the temperature and hence, the vapour pressure of the impure water contained in one vessel, to the point where pure water vapour will distil from impure effluent solution (tap water or brine) and condense in a second vessel used to collect pure water. Pure effluent production rates of between 0.5 and 4.3 kg h{sup -1} were obtained. The actual coefficient of performance (COP{sub A}) and the heat pump effectiveness varied from 1.1 to 1.4 and 0.58 to 0.72, respectively. The results from the small scale systems indicate ...

1999-05-01

198

Microbiologically influenced corrosion of carbon and stainless steel pipes; Mikrobiologisch beeinflusste Korrosion an Rohrleitungen aus unlegierten und hochlegierten nichtrostenden Staehlen  

Energy Technology Data Exchange (ETDEWEB)

About ten years ago microbiologically influenced corrosion manifested on stainless steel pipes used with river water for cooling a chemical plant. The pipe material was similar to Type 316 L. After only six weeks of operation pinhole leaks occurred nearly simultaneously at several welded joints of the pipe. The material degradation was simulated in laboratory and field corrosion tests. Microbiologically influenced corrosion failures also appeared on the pipes of a tubular heat exchanger of duplex steel Type 31803 and on carbon and stainless steel pipes in industrial waste water purification plants after these plants had been modernized with a biological purification unit. The basics of microbiologically influenced corrosion phenomena and typical corrosion failures of pipes will be described. (orig.) [German] Vor etwa zehn Jahren sind in einer neu errichteten chemischen Produktionsanlage an einer mit ...

1999-09-01

199

Chalon/Saint-Marcel manufacturing plant; L'usine de Chalon/Saint-Marcel  

Energy Technology Data Exchange (ETDEWEB)

AREVA is the world leader in the design and construction of nuclear power plants, the manufacture of heavy components, and the supply of nuclear fuel and nuclear services such as maintenance and inspection. The Equipment Division provides the widest range of nuclear components and equipment, manufactured at its two facilities in Jeumont, northern France, and St. Marcel, in Burgundy. The St. Marcel plant, set on 35 ha (87.5 acres) near Chalon-sur-Saone, was established in 1973 in a region with a long history of specialized metalworking and mechanical activities to meet the demand for non-military nuclear requirements in France. The site offers two advantages: - excellent facilities for loading and transporting heavy components on the Saone river, - it's proximity to other group sites. Since its completion in 1975, the Chalon/St. Marcel facility has manufactured all the heavy components for French pressurized water reactors (PWRs) ranging from 900 MW to 1500 ...

2008-07-01

200

Strontium-90 and cesium-137 in service water from June to December, 1981  

International Nuclear Information System (INIS)

Service water, 100 l each, was collected at an intake of a water treatment plant and at a tap after water was left running for five minutes. The carriers of strontium and cesium were added to water immediately after sampling, and the sample was vigorously stirred and filtered. Then it was passed through a cation exchange column at a rate of 80 ml/min. Strontium and cesium were eluted with hydrochloric acid from the cation exchange column, and separated. After the radiochemical separation, the mounted precipitates were counted for activity using low background beta counters normally for 60 min. Net sample counting rates were corrected for counter efficiency, recovery, self absorption and decay to obtain the content of strontium-90 and cesium-137 radioactivity per sample aliquot. From the results, concentrations of these nuclides in the original sample were ...

1981-12-01

201

Assessment, development and coordination of technology base studies in enhanced heat transfer. Quarterly progress report No. 7, March 1, 1983-May 31, 1983  

Energy Technology Data Exchange (ETDEWEB)

The major goal of this continuation project is to advance the utilization of heat transfer enhancement techniques in commercial heat exchange equipment. Thirteen heat transfer enhancement techniques have been identified as having potential for improving heat transfer coefficients in full-scale industrial equipment. The following tasks are part of this project, which was originally planned for three years: (1) expansion of technology information base; (2) evaluation of performance of enhanced surfaces and inserts; (3) correlation of data for spirally fluted surfaces; (4) study of structured surfaces in pool boiling; and (5) study of structured surface in spray film evaporation.

1983-08-01

202

Heating and cooling with geothermal energy: trends and accomplishments; Solutions de chauffage et de climatisation utilisant l`energie geothermique: tendances et realisations  

Energy Technology Data Exchange (ETDEWEB)

Recent developments in heat pump technology have made geothermal-based heat exchange systems particularly well-suited for the heating and cooling needs of buildings even in cold climates. The principles of geothermally-coupled heat pump heating and cooling systems were presented. Results of an in-situ study conducted by Hydro-Quebec on the efficiency of the geothermal heat pump system installed at the Saint-Hyacinthe professional school were summarized. This investigation was meant to be a case study of the applicability of these new technologies to the needs of the Quebec market. After the first year of service, the Saint-Hyacinthe system clearly demonstrated its cost effectiveness over conventional systems. It was predicted that geothermal heat pump systems will gain in popularity in Quebec because they can fully meet ...

1996-03-01

203

Heat transfer in parallel plate duct with a sinusoidal wave plate uniaxially inserted (1st). Effect of wave length on heat transfer augmentation  

Energy Technology Data Exchange (ETDEWEB)

High-performance heat transfer augmentation methods applicable in the forced convection field of heat exchangers include a method which requires no external drive means, such as the insertion of a turbulence augmentation object into the flow passage and the use of a wave-shaped flow passage, but disturbs the main stream of flow to raise the heat transportation effect thereby to augment heat transfer in the flow passage. The heat transfer characteristics and thermal performance ratio achieved when sinusoidal-shape plates are inserted instead of augmentation objects, such as cylinders, with a high shape-induced resistance were studied. As a result, the relationship between the resistance coefficient, average Nusselt number, heat transfer coefficient, and pitch was clarified. It has been revealed that the use of eddies with a large gap flow and ...

1988-09-01

204

Augmentation of heat transfer in a tube with an oscillating thin plate. Shindohen sonyu ni yoru enkannai netsudentatsu sokushin  

Energy Technology Data Exchange (ETDEWEB)

An attempt is made to augment the heat transfer efficiency by means of inserting an oscillating thin plate into a tube of the shell and tube heat exchanger. However, the heat transfer augmenting mechanism has not been fully explained. To elucidate this heat transfer augmenting mechanism, an investigation was given on the heat transfer characteristics of a tube inlet at its preliminary run area when a double-hinged oscillating thin plate is inserted in the inlet. As a result of the experiment, the heat transfer augmentation in the tube as a result of inserting the double-hinged oscillating thin plate was found effective when the preliminary inlet run area is treated as the object. However, in comparison of the effect with the heat transfer in a fully developed turbulent region, it was {eta}- 1. The result thus obtained ...

1991-09-01

205

An assessment of the building sector efficiency resource for the Town of Handlova  

Energy Technology Data Exchange (ETDEWEB)

Purpose of this assessment for this town in the Slovak Republic is to develop information on the building sector energy efficiency and improvement potential for use by town management to support decisions on providing energy services to Handlova citizens. Objectives were to characterize baseline space and water heat energy use and efficiency improvement potential in the residential and nonresidential building sectors. Intention was to identify major areas of efficiency improvement potential and cost-effectiveness. Four levels of energy and fuel prices were used. A significant efficiency resource exists in the space and water heating end uses in these building sectors; it amounts to 42% of the total building sector space and water heat energy consumption.

1995-10-01

206

Cooling facility for reactor container  

International Nuclear Information System (INIS)

Cooling water is sprayed on the outer surface of an upper portion of a container, and a pool is formed by the cooling water flowing down while cooling the container. Further, the cooling water stored in the cooling water pool is recycled by a pump for spraying the cooling water on the outer surface of the upper portion of the container. Sufficient amount of cooling water is supplied for spraying the cooling water to the outer surface of the upper portion of the container so that the outer surface of the container is free from drying and a liquid membrane is formed on the entire surface. The amount of the cooling water is made greater than that of the cooling water evaporated when the entire amount of the heat generate in the reactor core of the reactor is transferred to the ...

1993-05-07

207

Flooded Underground Coal Mines: A Significant Source of Inexpensive Geothermal Energy  

Energy Technology Data Exchange (ETDEWEB)

Many mining regions in the United States contain extensive areas of flooded underground mines. The water within these mines represents a significant and widespread opportunity for extracting low-grade, geothermal energy. Based on current energy prices, geothermal heat pump systems using mine water could reduce the annual costs for heating to over 70 percent compared to conventional heating methods (natural gas or heating oil). These same systems could reduce annual cooling costs by up to 50 percent over standard air conditioning in many areas of the country. (Formatted full-text version is released by permission of publisher)

2007-04-01

208

Lead exposure via drinking water - unnecessary and avoidable  

International Nuclear Information System (INIS)

Despite successful reduction of the general lead exposure, this heavy metal is still a matter of public concern due to the fact that associations with intellectual impairment or delayed puberty are found to correlate with very low lead blood concentrations. Lead in tap water is still an important contribution to lead exposure which may cause health risk for infants. Therefore, lead pipes should be completely sanitated by exchange against pipes made from more healthy materials. (orig.)

209

Determination of [sup 99]Tc in sea water at ultra low levels  

Energy Technology Data Exchange (ETDEWEB)

A method based on the collection of [sup 99]Tc from 500 l sea water samples by anion exchange and further extraction of TcO[sub 4][sup -] into 5% triisooctylamine-xylene has been improved to include a decontamination factor 6.5x10[sup 5] for uranium. The detection limit for [sup 99]Tc is thereby reduced to 3 mBq/m[sup 3].

1994-01-20

210

PWR horizontal steam generator in USSR  

International Nuclear Information System (INIS)

This paper describes the construction of PWR horizontal steam generator in Soviet Union, the water chemistry treatment for secondary side, the design of steam separator, the test of heat transfer characteristics and operation. (author).

1985-01-01

211

Numerical Simulation of Cirrus Clouds - Fire Case Study and ...  

Science.gov (United States)

... being pulled out of water, the movement is restricted ... This heating depended on the particle size ... hydrometeor injection into the upper tropopause. ...

1991-08-12

212

High quality water supply system; Joshitsusui kyokyu system  

Energy Technology Data Exchange (ETDEWEB)

This paper, firstly, introduces the background in developing a high quality water supply system, in which the drinking water system is isolated inside a building. Results of questionnaire on the high quality service water are illustrated. The results of questionnaire have revealed that the high quality service water is extremely interested. Then, are described the target quality of high quality water, the constitution of high quality water supply system, the treatment process, the measures to secure safety and sanitary, and the method of maintenance. The high quality water is produced through the activated charcoal absorption treatment, membrane treatment, ozonation, cooling, mineral addition, and disinfection of city water. Furthermore, application examples of this system adopted to a department store and a bachelor ...

1995-01-15

213

Northward Market Extension for Passive Solar Water Heaters by Using Pipe Freeze Protection with Freeze-Tolerant Piping: Preprint  

Energy Technology Data Exchange (ETDEWEB)

Conference paper regarding research in freeze-protection methods that could extend market acceptance for passive solar domestic water heating systems in more northern climates if the U.S.

2006-05-01

214

Nomographs for the rapid prediction of salt quality and influent water quality impacts on hardness leakage in steamflood water  

Energy Technology Data Exchange (ETDEWEB)

Counter-current regeneration of 2-stage sodium zeolite softeners has been employed in reducing hardness leakage level of steamflooding water to less than 1 ppm when raw water contains as much as 5,000 ppm of the total dissolved solids. Hardness leakage is caused by sodium displacement of calcium and magnesium from the bottom of the exchanger bed. This study presents nomographs providing for rapid calculations to be made, for which a convenient operational mode does not already exist. The nomographs relate the hardness leakage as a function of salt quality and influent water quality and present solutions for predicting the leakage level, salt quality requirement or the treatability of raw water required for steamflooding projects.

1982-08-01

215

Modeling of boiling- and tow-phase flow in offset-strip-fin heat-exchanger geometries  

Energy Technology Data Exchange (ETDEWEB)

The two-phase heat-transfer and pressure-drop characteristics of offset-strip-fin heat-exchanger geometries are examined using both experimental and analytical modeling techniques. Newly-obtained boiling-flow heat-transfer data are presented for two large-scale offset fin geometries at low-to-moderate wall-superheat conditions. Data for which nucleate boiling appeared to be completely suppressed were analyzed together with similar results for other offset fin surfaces to study the effects of channel dimensions on the convective evaporation component of the local heat transfer coefficient. Although these data were found to be well correlated in terms of modified forms of the F and Martinelli parameters used in previous studies of round-tube flows, a single F-factor correlation valid for all combinations of fin and channel dimensions did not appear to exist. The two-phase pressure-drop characteristics of ...

1988-01-01

216

Promising materials for HTGR high temperature heat exchangers  

International Nuclear Information System (INIS)

The service conditions for high-temperature heat-exchangers with helium coolant of HTGRs and requirements imposed on materials for their production are discussed. The choice of nickel-base alloys with solid-solution hardening for long-term service at high temperatures is grounded. Results of study on properties and structure of types Ni-25Cr-5W-5Mo and Ni-20Cr-20W alloy in the temperature range of 900 deg. - 1,000 deg. C are given. The ageing of Ni-25Cr-5W-5Mo alloy at 900 deg. - 950 deg. C results in decreased corrosion-mechanical properties and is caused by the change of structural metal stability. Alloy with 20% tungsten retains a high stability of both structure and properties after prolonged exposure in helium at above temperatures. The alloy has also increased resistance to delayed fracture and low-cycle fatigue at high temperatures. The developed alloy of type Ni-20Cr-20W with microalloying is recommended for production of tubes for HTGR high-temperature ...

1989-06-01

217

Prediction of the lifetime behaviour for C/C-SiC tubes as high and ultrahigh temperature heat exchangers (HITHEX) - material characterisation and qualification  

Energy Technology Data Exchange (ETDEWEB)

Heat exchangers for high and ultrahigh temperatures are a need and a precondition to realise high efficient fossil fired power plants based on the so-called Externally Fired Combined Cycle (EFCC) or the Indirect Fired Gas Turbines (IFGT). The main target of both processes is to increase the thermal efficiency of existing power plants by approximately 25% resulting in the same decrease in fuel consumption and, therefore, in the same reduction of CO{sub 2} formation. The main activities of the MPA University of Stuttgart in this project is focused on the characterisation and qualification of the structural material of the ultrahigh temperature heat exchanger (UHTHE) necessary in the above mentioned processes. The influence of the temperature and load on the material behaviour have been analysed by means of tensile tests and creep tests. The effectiveness of different coating systems and the interaction ...

2004-07-01

218

Subcooled Flow Boiling in a Minichannel  

British Library Electronic Table of Contents (United Kingdom)

It has been considered that dry-out occurs easily in boiling heat transfer for a small channel, a mini- or microchannel, because the channel was easily filled with coalescing vapor bubbles. In the present study, the experiments of subcooled flow boiling of water were performed under atmospheric conditions for a horizontal rectangular channel for which the size is 1 mm height and 1 mm width, with a flat heating surface of 10 mm length and 1 mm width placed on the bottom of the channel. The heating surface has a top of copper heating block and is heated by ceramic heaters. In the high heat flux region of nucleate boiling, about 70-80% of the heating surface was covered with a large coalescing bubble and the boiling reached critical heat flux as observed by high-speed video. In the beginning ...

2011-01-01

219

Glass-heat-pipe evacuated-tube solar collector  

Science.gov (United States)

A glass heat pipe is adapted for use as a solar energy absorber in an evacuated tube solar collector and for transferring the absorbed solar energy to a working fluid medium or heat sink for storage or practical use. A capillary wick is formed of granular glass particles fused together by heat on the inside surface of the heat pipe with a water glass binder solution to enhance capillary drive distribution of the thermal transfer fluid in the heat pipe throughout the entire inside surface of the evaporator portion of the heat pipe. Selective coatings are used on the heat pipe surface to maximize solar absorption and minimize energy radiation, and the glass wick can alternatively be fabricated with granular particles of black glass or obsidian.

1981-08-06

220

The deep borehole heat exchanger in Weggis - Performance monitoring after increasing the heat output power; Tiefe Erdwaermesonde Weggis. Messkampagne zur Dokumentierung der neuen Einfluesse beim Ausbau der Abnehmerleistung  

Energy Technology Data Exchange (ETDEWEB)

The deep borehole heat exchanger (BHE) of Weggis is operational since 1994. During the years 1995 to 2000 the BHE has produced for both, direct heating and as a source for the heat pumps, a yearly amount of heat of 220 MWh. The share of direct heating has been more than 60%. The global average power delivered to all consumers has been about 100 kW. This has yielded to a mean source temperature out of the deep BHE of 40.5 {sup o}C and to a mean return temperature of 33.3 {sup o}C. During the years 2000 and 2001 three additional multi-family dwellings have been connected as heat consumers to the BHE. The amount of delivered heat has nearly been doubled (from 220 to 440 MWh per year) as well as the nominal load. This has induced a small reduction of the delivery temperature and a significant reduction of the return ...

2003-07-01

221

Assessment of cadmium in aquatic sediment using dialysis samplers with ion-exchange-resin collection  

Energy Technology Data Exchange (ETDEWEB)

Simultaneously extracted metals (SEM) and acid volatile sulfide (AVS) show the potential for toxicity on the basis of their ratio. Accordingly, the authors spiked cadmium in a range for which Cd/AVS ratios were from 0.2 to 10 in the sediment with its weight about 8 kg in each batch. Dialysis samplers with a cation ion-exchange resin (Dowex 50W-X4) collection were used in a laboratory for the determination of free cadmium concentrations in pore water of the collected sediment. When equilibrium was reached among cadmium in pore water, sediment, and ion-exchange resin, cadmium exchanged onto resin phase was regenerated with 1 N hydrochloric acid (OPTIMA grade) and determined using an atomic absorption spectrophotometer (Zeeman 5000) with a graphite furnace accessory. Cadmium determined using the dialysis sampler is considered as free cadmium which is related to the metal ...

1998-05-01

222

A desiccant dehumidifier for electric vehicle heating  

Energy Technology Data Exchange (ETDEWEB)

Vehicle heating requires a substantial amount of energy. Engines in conventional cars produce enough waste heat to provide comfort heating and defogging/defrosting, even under very extreme conditions. Electric vehicles (EVs), however, generate little waste heat. Using battery energy for heating may consume a substantial fraction of the energy storage capacity, reducing the vehicle range, which is one of the most important parameters in determining EV acceptability. Water vapor generated by the vehicle passengers is in large part responsible for the high heating loads existing in vehicles. In cold climates, the generation of water vapor inside the car may result in water condensation on the windows, diminishing visibility. Two strategies are commonly used to avoid condensation on windows: windows are ...

1996-09-01

223

Performance characteristics of a natural circulation cooling/latent heat storage system  

Energy Technology Data Exchange (ETDEWEB)

A cooling system was developed which could be used even in such areas where the maximum and minimum temperatures of a day might differ widely. The system features in that a latent heat storage unit is connected to the natural circulation cooling unit consisting of 2 heat exchangers where condensed gas (refrigerant) which performs gas-liquid change has been sealed, enabling to cool objects night and day without the requirement for any power source. Electronic equipment was installed in an insulated shelter. Lauric acid and refrigerant R-22 were used as the latent heat storage medium and the heat transport medium respectively. Natural convection heat transfer performance of the outside surfaces of the condenser and the evaporator and the transient behavior of the system during the melting and solidification periods of the latent heat storage ...

1987-09-25

224

Special eddy current probes for heat exchanger inspection  

International Nuclear Information System (INIS)

Until a decade ago, only the differential bobbin type eddy current probe was considered necessary for reliable heat exchanger tube inspection. The introduction of different tube materials, manufacturing processes and a variety of service induced failures has greatly increased the demands of eddy current testing. Optimized probe designs enhanced by improved instrumentation can help satisfy some of these demands. Some of the more difficult inspection problems are detection of circumferential cracks, fretting wear under non-ferromagnetic support plates and shallow internal defects. Reliable detection and sizing of such defects is often made more difficult by the fact they frequently occur in defect prone regions such as under tubesheets or support plates and in transition regions of finned tubes. Probe designs effective in overcoming these difficulties exist. This paper describes a number of such probes and their performance.

1986-11-17

225

Multi-Dimensional Analysis for Sodium Hot Pool using MARS-LMR in Steady State  

International Nuclear Information System (INIS)

DBEs (Design Basis Event) of KALIMER-600 (Korea Advanced Liquid Metal Reactor) were analyzed in one dimension by KAERI (Korea Atomic Energy Research Institute). KALIMER-600 is the pool type SFR (Sodium cooled Fast Reactor), thereby the sodium of primary system is prohibited movement to out of a reactor vessel. There are many contacting and including compositions in the sodium hot pool, such as IHX (Intermediate Heat eXchanger), DHX (Decay Heat eXchanger), Pump, UIS (Upper Internal Structure), and core. Moreover, the complex phenomena are occurred in sodium hot pool during steady and transient states. Therefore, the one dimensional analysis is modified to the multi-dimensional analysis through modification of sodium hot pool from one to three dimensions

2010-10-01

226

Intervention device, especially for control, inspection and maintenance of heat exchangers. Dispositif d'intervention, notamment pour le controle, l'inspection et la maintenance des echangeurs de chaleur  

Energy Technology Data Exchange (ETDEWEB)

The steam generator inspection and maintenance device has an articulated arm formed at least by two rigid segments connected by a pivot and two plates on the ends of the arms by articulated joints which enable them to rotate about two orthogonal axis. One of the axis is parralel to the axis of the pivot between the arm sections while the other is perpendicular to the surface of the corresponding plate. Each of the plates carries coupling elements which are able to engage with the perforations of the heat exchanger tube plates and also a support for a maintenance tool.

1990-09-21

227

Fluidelastic instability of heat exchanger tube bundles; Review and design recommendations  

Energy Technology Data Exchange (ETDEWEB)

This paper reports that fluidelastic instability is the most important vibration excitation mechanism for heat exchanger tube bundles subjected to cross-flow. Most of the available data on this topic have been reviewed from the perspective of the designer. Uniform definitions of critical flow velocity for instability, damping, natural frequency and hydrodynamic mass were used. Nearly 300 data points were assembled. The authors found that only data from experiments where all tubes are free to vibrate are valid form a design point of view. In liquids, fluid damping is important and should be considered in the formulation of fluidelastic instability. From a practical design point of view, we conclude that fluidelastic instability may be expressed simply in term of dimensionless flow velocity and dimensionless mass-damping. There is no advantage in considering more sophisticated models at this time. Practical design guidelines are discussed.

1991-05-01

228

Calculation of the view factors for radiant heat exchange in a new volumetric receiver with tapered ducts  

Energy Technology Data Exchange (ETDEWEB)

The need to increase efficiency of volumetric receivers for use in solar power plants by reducing reradiation losses and increasing the ``volumetric effect`` has promoted the idea of a receiver with tapered ducts. These seems to be very promising since higher efficiency and considerable saving of material can be achieved, as compared to conventional receivers perforated with ducts of constant cross-section. A finite element program is being developed to calculate stationary heat transfer in the tapered ducts by free and forced convection in the gas flow, conduction in walls and in the gas, and solar and thermal radiation. Gas and wall temperatures are considered to be varying only in the flow direction. In order to perform the highly nonlinear calculations of radiative exchange, the exact knowledge of the view factors is necessary. The aim of the present work is to evaluate analytically the view factors in tapered ducts.

1995-02-01

229

Ion exchange resins for water purification : properties and characterisation  

International Nuclear Information System (INIS)

The report is divided into three sections. The first section contains a general introduction to ion exchange resins used in various processes, the second section describes characteristic properties of the polymer materials and the inter relation between them. This will, in turn, be useful to interpret the data obtained from the various tests carried out on the resins in the laboratory. In the third section of the report, are given the details of each method used for a particular test to be carried out on a routine basis. Each method describes the principle involved, the reagents and apparatus used in the experiment, the actual procedure and calculations and recording of the data. 3 refs. (author).

2005-03-14

230

Waste heat utilization in the thermal spa of Lavey-les-Bains; Etude de la valorisation des rejets thermiques des Bains de Lavey  

Energy Technology Data Exchange (ETDEWEB)

This final report for the Swiss Federal Office of Energy looks at the possibilities for improved waste water utilization in the Lavey-les-Bains thermal spa, Switzerland. According to the regulations in force, the temperature of the waste water rejected into the Rhone river shall not exceed 30 {sup o}C, what is currently not the case. Also the operational cost shall be reduced and the waste water quality improved. The installations are presented. From the two geothermal wells, mineral water comes out at an average flow rate of 940 l/min and a temperature of 63 {sup o}C. Actual waste water data are reported. The measured thermal water consumption data, including seasonal variations, are analysed by computerized simulation and measures to reduce the consumed volume by the optimization of internal procedures are evaluated. Measures to reduce the quantity of the ...

2004-07-01

231

Waste heat utilization in the thermal spa of Lavey-les-Bains  

International Nuclear Information System (INIS)

This final report for the Swiss Federal Office of Energy looks at the possibilities for improved waste water utilization in the Lavey-les-Bains thermal spa, Switzerland. According to the regulations in force, the temperature of the waste water rejected into the Rhone river shall not exceed 30 "oC, what is currently not the case. Also the operational cost shall be reduced and the waste water quality improved. The installations are presented. From the two geothermal wells, mineral water comes out at an average flow rate of 940 l/min and a temperature of 63 "oC. Actual waste water data are reported. The measured thermal water consumption data, including seasonal variations, are analysed by computerized simulation and measures to reduce the consumed volume by the optimization of internal procedures are evaluated. Measures to reduce the quantity of the rejected free ...

232

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 3, Water heaters, pool heaters, direct heating equipment, and mobile home furnaces  

Energy Technology Data Exchange (ETDEWEB)

This is Volume 3 in a series of documents on energy efficiency of consumer products. This volume discusses energy efficiency of water heaters. Water heaters are defined by NAECA as products that utilize oil, gas, or electricity to heat potable water for use outside the heater upon demand. These are major appliances, which use a large portion (18% on average) of total energy consumed per household (1). They differ from most other appliances in that they are usually installed in obscure locations as part of the plumbing and are ignored until they fail. Residential water heaters are capable of heating water up to 180{degrees}F, although the setpoints are usually set lower.

1993-11-01

233

Advanced Binary Geothermal Power Plancts Working Fluid Property Determination and Heat Exchanger Design  

Energy Technology Data Exchange (ETDEWEB)

The performance of binary geothermal power plants can be improved through the proper choice of a working fluid, and optimization of component designs and operating conditions. This paper reviews the investigations at the Idaho National Engineering Laboratory (INEL) which are examining binary cycle performance improvements: for moderate temperature (350 to 400 F) resources with emphasis on how the improvements may be integrated into design of binary cycles. These investigations are examining performance improvements resulting from the supercritical vaporization of mixed hydrocarbon working fluids and achieving countercurrent integral condensation with these fluids, as well as the modification of the turbine inlet state points to achieve supersaturated turbine vapor expansions. For resources where the brine outlet temperature is restricted, the use of turbine exhaust recuperators is examined. The baseline plant used to determine improvements in plant performance (characterized by the ...

1989-03-21

234

Determining effective soil formation thermal properties from field data using a parameter estimation technique  

Energy Technology Data Exchange (ETDEWEB)

A one-dimensional thermal model is derived to describe the temperature field around a vertical borehole heat exchanger (BHEx) for a geothermal heat pump. The inlet and outlet pipe flows are modeled as one, and an effective heat capacity is added to model the heat storage in the fluid and pipes. Parameter estimation techniques are then used to estimate various parameters associated with the model, including the thermal conductivity of the soil and of the grout which fills the borehole and surrounds the u-tube. The model is validated using test data from an experimental rig containing sand with known thermal conductivity. The estimates of the sand thermal conductivity derived from the model are found to be in good agreement with independent measurements.

1998-11-01

235

Determining Effective Soil Formation Thermal Properties From Field Data Using A Parameter Estimation Technique  

Energy Technology Data Exchange (ETDEWEB)

A one-dimensional thermal model is derived to describe the temperature field around a vertical borehole heat exchanger (BHEX) for a geothermal heat pump. The inlet and outlet pipe flows are modeled as one, and an effective heat capacity is added to model the heat storage in the fluid and pipes. Parameter estimation techniques are then used to estimate various parameters associated with the model, including the thermal conductivity of the soil and the grout that fills the borehole and surrounds the U-tube. The model is validated using test data from an experimental rig containing sand with known thermal conductivity. The estimates of the sand's thermal conductivity derived from the model are found to be in good agreement with independent measurements.

1999-01-01

236

FT-IR spectroscopic studies of hydrocarbon trapping in Ag{sup +}-ZSM-5 for gasoline engines under cold-start conditions  

Energy Technology Data Exchange (ETDEWEB)

A detailed study of adsorption of automobile exhaust hydrocarbons in Ag{sup +}-exchanged zeolites under cold-start conditions (room temperature and in the presence of water) was carried out with FT-IR spectroscopy, using toluene and propylene as probes. The results show that exchanged Ag{sup +} in zeolites is unique for trapping olefin and aromatic hydrocarbons due to its resistance to water adsorption. In contrast, exchanged Cu{sup 2+} in zeolites, which has good hydrocarbon trapping properties under dry conditions, does not trap hydrocarbons under wet conditions. Here, solvation of Cu{sup 2+} screens the interactions of the cation with adsorbed hydrocarbons. The results also show that, in addition to the nature of the cation, the structure of the zeolite also plays a role in hydrocarbon trapping. Aging at high temperatures, with water vapor (=10%) and SO{sub ...

2001-12-28

237

Simplified solar fraction estimation for space and water heating at DOD installations. Final report  

Energy Technology Data Exchange (ETDEWEB)

A set of nomographs is provided which can be used to estimate the average annual solar fraction for solar space and water heating at a large number of DOD facilities. The solar fraction estimated from the nomograph is in close agreement with F-Chart 3.0 and allows for variation of the following parameters: annual load, collector area, collector transmittance-absorption coefficient, and collector overall loss coefficient.

1982-09-01

238

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

International Nuclear Information System (INIS)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-22

239

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

Energy Technology Data Exchange (ETDEWEB)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-01

240

The thermal response of an infinite line of open loop wells for ground coupled heat pump systems  

British Library Electronic Table of Contents (United Kingdom)

Ground thermal energy storage is a means of storing thermal energy underground during the summer and utilizing it during the winter. The main use of such a technology is in the heating, ventilating and air conditioning sector where the ground provides a stable temperature reservoir for a heat pump system. Heat pumps are mechanical systems that provide heating to a space in the winter, and cooling in the summer. They are increasingly popular because the same system provides both heating modes, depending on the direction of the cycle upon which they operate. The stable temperature reservoir allows the heat pump system to run at a higher efficiency. Thermal energy is transmitted to and from the ground by circulation of water through standing column geothermal wells. In commercial applications...

2011-01-01

241

A metal matrix for heat transfer enhancement during phase-change processes  

Energy Technology Data Exchange (ETDEWEB)

A metal matrix is inserted into a phase-change material to enhance the heat transfer during phase-change processes. The metal matrix tends to act like a heat transfer fin from the heated or cooled surface and to increase the effective thermal conductivity of the phase-change fluid. The scope of the study involves numerically modeling the heat transfer to and from constant-temperature cylindrical tubes surrounded by water during the freezing and melting processes. Comparisons of heat transfer with and without the metal matrix are made, with different porosities and densities of the metal matrix being examined. The results of this study are discussed in terms of the effectiveness of the metal matrix as a heat transfer enhancement device.

1994-12-31

242

Necessity for usage of geothermal heat pump  

International Nuclear Information System (INIS)

Every day we are witnesses of constantly rapid increase of consumption of Electric energy in R. of Macedonia as so as in the other countries in all the world. This rapid increase of consumption of Electric energy independent of a lot of electrical units, which are applying in human life like: homes, administration and publication objects, as well as in industry. All of this conditions make us to thinking how is possible more rational consumption of electric energy in all areas in human life. One of the possible manners to reduce the consumption of electrical energy for heating and cooling is to use geothermal heat pumps. In this paper will be proposed geothermal heat pump, which is going to use the heat of earth by vertical and horizontal cupper pipe heat exchanger with data from-GHP (Geothermal Heat Pump) NORDIC, factory in Canada. Also, it ...

2004-10-07

243

A unified model of combined energy systems with different cycle modes and its optimum performance characteristics  

Energy Technology Data Exchange (ETDEWEB)

A unified model is presented for a class of combined energy systems, in which the systems mainly consist of a heat engine, a combustor and a counter-flow heat exchanger and the heat engine in the systems may have different thermodynamic cycle modes such as the Brayton cycle, Carnot cycle, Stirling cycle, Ericsson cycle, and so on. Not only the irreversibilities of the heat leak and finite-rate heat transfer but also the different cycle modes of the heat engine are considered in the model. On the basis of Newton's law, expressions for the overall efficiency and power output of the combined energy system with an irreversible Brayton cycle are derived. The maximum overall efficiency and power output and other relevant parameters are calculated. The general characteristic curves of the system are presented for some given parameters. ...

2009-06-15

244

Visualization of direct contact heat transfer between water and molten alloy  

Energy Technology Data Exchange (ETDEWEB)

We have been developing an innovative Steam Generator concept of Fast Breeder Reactors by using liquid-liquid direct contact heat transfer. In this concept, the SG shell is filled with a molten alloys, which is heated by primary sodium. Water is fed into the high temperature molten alloy, and evaporates by direct contact heating. In order to obtain the fundamental information to discuss the heat transfer mechanisms of the direct contact between the water and the alloy, this phenomenon was visualized by real-time neutron radiography. JRR-3M real-time thermal neutron radiography in Japan Atomic Energy Research Institute was used. Followings are main results. (1) The vigorous evaporation occurs in the molten alloy. This phenomena is different from the known phenomenon such as the evaporation of refrigerant R-113 in the water. (2) The ...

1996-06-01

245

Mathematical modeling of a direct contact humidification?dehumidification desalination process  

British Library Electronic Table of Contents (United Kingdom)

Using air as a carrier gas is common in humidification?dehumidification desalination processes. A computer program was written using mass and energy balances for modeling the process behavior. The parameters considered in this work were inlet air and fresh water recycle temperatures, inlet air flow rate, saline water and fresh water recycle flow rates, and saline water to air flow ratio. Results of simulation showed that increasing inlet air and fresh water recycle flow rate increases fresh water production. It was also found that heating the inlet air to humidification column or cooling the inlet water to dehumidification column increases the production rate but increasing water to air flow ratio in a humidifier leads to a lower production rate. The predicted effects of the parameters on ...

2009-01-01

246

Some sensitivities during a LWR severe core-damage sequence  

International Nuclear Information System (INIS)

Stable boiloff of core water during a severe LWR accident, that is, boiloff driven only by the decay power generated below the water level, is tractable analytically and is relatively insensitive to axial power distribution. As might be expected, calculated accident event times are sensitive to the fidelity of the decay power model. During later stages of boiloff, heat transfer or transport of energy from above the water level to the residual water can result in an unstable condition during which the boiloff rate increases greatly. The unstable boiloff phenomenon illustrates the highly nonlinear influence of core heat transfer during meltdown and emphasizes the great accuracy requirements which attend the modeling of the accident during periods of enhanced heat transfer when significant zirconium oxidation is possible.

1981-12-04

247

Hot-air turbine plant at Voelklingen model power plant  

Energy Technology Data Exchange (ETDEWEB)

The integration of a gas turbine into a new type of coal-fired combined cycle power plant necessitates a multiplicity of far-reaching changes compared with a normal design. The extremely high pre-heating temperature of the air emanating from the heat exchanger of the fluidized bed for the gas turbine combustion chamber has necessitated extensive development work and associated combustion trials. It was possible for these results to influence the design of the burners whereas the manufacture of other components which was on the critical path was already far advanced.

1984-06-01

248

FB-Line resin testing final report  

Energy Technology Data Exchange (ETDEWEB)

The Dowex 50W-X8 and 50W-Xl2 resin samples are both strong acid cation materials in the hydrogen form. Each material has a water retention capacity characteristic of its respective marketed degree of cross-linking. Dowex 21K gives confirmatory responses to tests for a strong anion exchange resin in the nitrate form. All three resins have the manufacturer's specified ionic type and form, and the Dowex 50W resins have characteristic water retention capacities. These tests conclude that the ion exchange resins in use in FB-Line meet the approved safety document criteria for cross-linking, ionic form, and resin type.

1992-01-23

249

FB-Line resin testing final report  

Energy Technology Data Exchange (ETDEWEB)

The Dowex 50W-X8 and 50W-Xl2 resin samples are both strong acid cation materials in the hydrogen form. Each material has a water retention capacity characteristic of its respective marketed degree of cross-linking. Dowex 21K gives confirmatory responses to tests for a strong anion exchange resin in the nitrate form. All three resins have the manufacturer`s specified ionic type and form, and the Dowex 50W resins have characteristic water retention capacities. These tests conclude that the ion exchange resins in use in FB-Line meet the approved safety document criteria for cross-linking, ionic form, and resin type.

1992-01-23

250

Advanced resin cleaning system  

International Nuclear Information System (INIS)

Novel and unprecedented ion exchange resin cleaning system, for use in BWR plants and featuring a vibration separator and basic design factors of Radiological Solutions, Inc., had been delivered to Tokai No. 2 Power Station, Japan Atomic Power Company, in October 2005. This compactly-designed system effectively separates crud and resin fines from ion exchange resins, with no clogging of separation screens. It generates minimized waste liquid and has a specially designed over-pack cleaning tank. The system has been in operation for about 2 years and half now and favorable operational data, such as crud and sulfate concentration decrease in feed water and reactor water respectively, and evaluation results have been reported from Japan Atomic Power Company and so on. (author)

2008-07-01

251

Modeling of snow melting and uniform wetting front migration in a layered subfreezing snowpack  

Energy Technology Data Exchange (ETDEWEB)

A method of modeling freeze-thaw cycles of naturally deposited snowpacks is presented. The model involves the Stefan condition as an independent governing equation on the exterior moving boundary to calculate snowpack thinning, flow of water through a variably saturated layered porous medium as described by the Richards equation, and heat conduction with a phase change. The heat conduction problem was treated in two ways. Local heat conduction between a snow grain and its surrounding water film was treated by using a simple energy balance. Global heat conduction with a phase change (the Stefan problem) was introduced to calculate the space-time temperature distribution. In order to handle multiple interior moving boundaries, a specific form of the enthalpy formulation was used for heat conduction with a phase change. Changing material ...

1994-08-01

252

Thermal-hydraulic characteristics of boiling water two-phase flow in narrow horizontal rectangular channel  

International Nuclear Information System (INIS)

Heat transfer and flow characteristics of water boiling flow were experimentally investigated in narrow horizontal rectangular channels with the gaps of 0.6mm-2.03mm. The heat transfer of two-phase boiling flow was weakend in smaller gap. The two-phase friction pressure drop decreased with the gap size and the two-phase friction multipliers were smaller compared with those in normal channels. Correlations to predict te boiling heat transfer coefficients were obtained. (author)

2003-05-28

253

Semiempirical model based on thermodynamic principles for determining 6 kW proton exchange membrane electrolyzer stack characteristics  

Energy Technology Data Exchange (ETDEWEB)

The performance of a 6 kW proton exchange membrane (PEM) electrolyzer was modeled using a semiempirical equation. Total cell voltage was represented as a sum of the Nernst voltage, activation overpotential and ohmic overpotential. A temperature and pressure dependent Nernst potential, derived from thermodynamic principles, was used to model the 20 cell PEM electrolyzer stack. The importance of including the temperature dependence of various model components is clearly demonstrated. The reversible potential without the pressure effect decreases with increasing temperature in a linear fashion. The exchange current densities at both the electrodes and the membrane conductivity were the coefficients of the semiempirical equation. An experimental system designed around a 6 kW PEM electrolyzer was used to obtain the current-voltage characteristics at different stack temperatures. A nonlinear curve fitting method was employed to determine the equation ...

2008-12-01

254

Experimental and theoretical studies on humidification-dehumidification-desalination  

Energy Technology Data Exchange (ETDEWEB)

The shortage of fresh water is increasing at alarming levels, even in temperate zones. Desalination of brackish and seawater is being considered as a solution to growing water demands. Seawater desalination can be accomplished through reverse osmosis, vapor compression, vapor absorption and thermally driven systems. The most suitable process for large-scale desalination plants is successive brine evaporation-condensation with intermediate heat recovery. However, higher process efficiency could be achieved. The use of low temperature heat sources in seawater desalination requires an efficient method of evaporation and condensation at relatively low vapor pressures. This could be achieved in a humidification-dehumidification process using circulated air to enhance evaporation of water. Simulation models, however, neglect either the heat of evaporation or the ...

2006-07-01

255

Safety provisions for steam generator in Mochovce nuclear power plant. BO CI 04 Integrity of primary collectors of VVER 440 steam generators  

International Nuclear Information System (INIS)

This paper dealt with the identification of possible damaging mechanism of the collector of the WWER 440 steam generator, cracking of primary collectors, corrosion damage of the protective coat of the primary collector circumferential weld, cracking of breathing space in the region of blinding effect by corrosion and strain, leaking of disassembling joint of the primary collector lid and with the integrity of heat exchanging tubes.

1997-11-19

256

Device for the inspection of curved pipes in steam raising units  

Energy Technology Data Exchange (ETDEWEB)

The chain of eddy current probes and a film cassette probe, which responds to radiation from a radio-active source in one of the heat exchanger pipes is examined. The probes are moved by nylon pipes on both ends of the chain through the pipe to be examined. The nylon pipes are bent off load. In this way the probes on the chain will adjust near to the plane of bending of the pipes to be tested.

1980-01-03

257

Microwave drying of fine coal  

Energy Technology Data Exchange (ETDEWEB)

Drying fine coal by microwaves is now being considered as a viable option by some coal producers. The interest in microwaves is due to problems encountered with current thermal or hot-air drying methods. The technical feasibility of drying minus 5mm coal fines by microwaves was demonstrated using pilot-scale continuous processing system. Results showed that water absorbs microwave energy significantly; but coal does not. Secondly, microwave energy heats only the water, unlike existing drying methods, which heat both water and coal. Finally, the method was found to be energy efficient and minimised the generation of dust.

1989-03-01

258

Overview of Cooling Water System for the KSTAR 1st Plasma Experiment  

International Nuclear Information System (INIS)

The KSTAR cooling water system (CWS) consists of a primary cooling water system (PCWS), a secondary cooling water system (SCWS), and a de-mineralizing and de-ionized water system (DIWS). The PCWS cooling loops have been made for the poloidal field (PF) and toroidal field (TF) magnet power supplies (MPS), vacuum vessel (VV), electron cyclotron heating (ECH), ion cyclotron heating (ICRH), vacuum pumps, diagnostics, helium facility, etc. The CWS had been done individual commissioning of each system to confirm the design specifications by the end of 2006 and had gradually begun operation for the KSTAR ancillary devices by March 2008

2009-05-01

259

The building tomorrow and after..; Le batiment demain et apres-demain..  

Energy Technology Data Exchange (ETDEWEB)

During its jubilee, the French building technical and scientific centre (CSTB) has organized a colloquium about the future tendencies of buildings evolution in the 20 forthcoming years: autonomy in energy production and wastes or effluents management, reduction of water consumption and management of water, hot water production and space heating, bio-sensors for the management of indoor air-quality, control of noise environment using active acoustic systems etc.. (J.S.)

1998-01-01

260

Lamp system for uniform semiconductor wafer heating  

Energy Technology Data Exchange (ETDEWEB)

A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.

2001-01-01

261

Depth of origin of the gas content in thermal waters  

Energy Technology Data Exchange (ETDEWEB)

The gas composition of recent thermal waters is in perfect conformity with their geologic-tectonic positions. The composition of gas-liquid inclusions in the basic-hyperbasic xenoliths of basaltoid lavas depends on the depth from which xenoliths are supplied. (The depth is determined by using the methods of geological thermobarometers). By comparing available data the conclusion was drawn that the gas compositions of thermal waters reflect the depth of generation of deep fluid which heats them and depends on the penetration depth of the fluid-conducting fissure zones.

1980-01-01

262

Effect on heat-transfer augmentation by channel width in a sinusoidal wave channel  

Energy Technology Data Exchange (ETDEWEB)

In the development of high performance heat transfer surface on a compact heat exchanger, it was clarified that how reattachment point heat transfer and fluid flow are affected by channel width, at the same time, an evaluation of heat transfer performance and an investigation of optimum channel width were carried out. The channel system used in the experiment is as follows; (1) blow-off type with rectangular section channel, (2) span length of 200 mm, (3) wave length (pitch) of 80 mm, and (4) channel length of 12.5 wave length. The channel Reynolds number was set at about 10/sup 4/ which is relatively higher than the current studies. The results of the experiment were summarized as follows. (1) The channel width H has relevance to the phase difference between the fluid flow in cone portion of main stream and wave shape, the flow patterns are divided roughly into three types. These ...

1988-06-25

263

Isotope exchange reaction between tritiated water and hydrogen on SiC  

Energy Technology Data Exchange (ETDEWEB)

SiC has been considered as a primary candidate material for a first wall component in future fusion reactor because it has been claimed that SiC has excellent high-temperature properties, good chemical stability and low activation. However, the behavior of tritium on SiC has not been discussed yet. In this study, tritium trapping capacity on the surface of SiC was experimentally obtained at the temperature range of 25-800 deg. C in consideration of tritium trapping to the experimental system. The capacity, which was independent of the water vapor pressure in the gas phase and the temperature, was determined as about 10{sup 6} Bq/cm{sup 2}. The isotope exchange reaction rate between tritiated water in a gas phase and hydrogen on the surface was quantified at the temperature of 25, 500 and 700 deg. C in consideration of the behavior of tritium trapping at change of experimental condition by the numerical curve fitting method ...

2003-11-15

264

Isotope exchange reaction between tritiated water and hydrogen on SiC  

International Nuclear Information System (INIS)

SiC has been considered as a primary candidate material for a first wall component in future fusion reactor because it has been claimed that SiC has excellent high-temperature properties, good chemical stability and low activation. However, the behavior of tritium on SiC has not been discussed yet. In this study, tritium trapping capacity on the surface of SiC was experimentally obtained at the temperature range of 25-800 deg. C in consideration of tritium trapping to the experimental system. The capacity, which was independent of the water vapor pressure in the gas phase and the temperature, was determined as about 10"6 Bq/cm"2. The isotope exchange reaction rate between tritiated water in a gas phase and hydrogen on the surface was quantified at the temperature of 25, 500 and 700 deg. C in consideration of the behavior of tritium trapping at change of experimental condition by the numerical curve fitting method applying ...

2003-11-15

265

Evaluation of the humidification requirements of new proton exchange membranes for fuel cells  

Science.gov (United States)

Measurements of PEM fuel cell device performance were made with different gas inlet temperatures and relative humidity using a newly-designed test fixture. Significant improvement in device performance was observed when the fuel inlet temperature was increased above the operating temperature of the cell. These measurements were then correlated to a model to describe energy and mass transport processes. Proton exchange membrane (PEM), fuel cells--the focus of this study--use an ion conducting polymer, especially polyperfluorosulfonic acid materials. These polymer materials, when imbibed with water, exhibit solution-like properties, but because the anions are chemically bound to the polymeric structure, the electrolyte is contained. Importantly, product water removal is simplified, as electrolyte dilution is not a concern. However, the proton transport rate is a function of the polymer geometry, which is set, in part, by the ...

1995-05-01

266

Studies on water treatment by adsorption. Kyuchaku ni yoru mizushori  

Energy Technology Data Exchange (ETDEWEB)

This paper summarizes studies on the water treatment by adsorption, as for the adsorption during water treatment, reactivation of activated charcoal, and clarification of heating process. Reactivation of activated charcoal for the water treatment is carried out through drying in the heating furnace. Basic problems are the recovery degree of adsorption performance of reactivated activated charcoal and the recovery yield. Behavior of the activated charcoal in the heating reactivation furnace is divided into three stages including drying process, heating process, and gasification process. Among these processes, behaviors of organic matters during heating process are described. Thermogravimetric analyses (TGA) were conducted for activated charcoals adsorbing various organic matters in aqueous solutions. Three types of ...

1994-06-05

267

Final report for the DOE Suede Project, (solar utilization/economic development and employment project)  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this solar energy project was to design, manufacture, install, maintain and evaluate solar heating systems in order to stimulate community acceptance of the practicality of solar applications, reduce non-renewable energy resource consumption, and decrease residential expenditures for energy. The project also provided skill training and experience for CETA employees in the design, manufacture, and installation of solar energy equipment systems. CDC's contract had four separate solar energy projects; namely: Domestic Water Heating Systems for four Single-Family Homes; Domestic Water Heating for an industrial building; Domestic Water Heating for a (4) unit apartment complex (includes (12) supplemental space heating units); and Integral Passive Water Heaters and Energy ...

1983-10-19

268

MINERGIE modules: heat pump - heat pump/solar - wood - wood/solar; Minergie-Module Waermepumpe - Waermepumpe/Solar - Holz - Holz/Solar  

Energy Technology Data Exchange (ETDEWEB)

This research report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that examined the feasibility of setting up 'MINERGIE' low-energy-consumption module standards for the production of heat in small residential buildings. The aims of the standards and the basic idea behind the MINERGIE-modules are discussed. The concepts of the modules for heat pumps and wood-fired heating systems and their combination with solar installations are examined, as are their areas of application. The requirements placed on the modules are listed. System concepts, including simple schematics for typical installations, are presented for wood-log, wood-chippings and pellets-fired systems as well as for ground-loop and air-water heat pump systems as well as their solar-aided counterparts. The results of cost-benefit analyses are presented and questions ...

2005-07-01

269

Comparison of stomach contents and condition of two catfish species living at ambient temperatures and in a heated discharge  

International Nuclear Information System (INIS)

The lower condition factors for two catfish species in water heated by effluents from APCo's Glen Lyn, Virginia plant as compared to control areas probably is not due to lack of food as evidenced by macroinvertebrate sampling and the fact that only 4.3 percent of the catfish stomachs were empty. Results suggested that young-of-the-year channel catfish were nonselectively eating food organisms present at both control and heated stations. The difference between stomach contents of flatheat catfish from the heated site and fauna available at that site indicated that fish were either moving out of the heated area to feed or were selectively feeding on organisms (particularly mayflies) which were in the substrate or drifted into the heated area. Stomach contents of the two species and distribution and abundance of the macroinvertebrate benthos community are detailed.

270

Improvement of leaching characteristics of TOC from condensate demineralizers  

International Nuclear Information System (INIS)

Recent nuclear power plants require high purity water to protect nuclear reactors or steam generators from SCC and maintain in good condition. In this connection, it is especially important to minimize sulfate, which is a corrosive chemical originated from oxidative degradation of cation exchange resins during operation. Recently, uniform particle size (UPS) strong acid cation gel resin with 14% cross-linkage, which has excellent stability against oxidization, has been applied to several condensate purification systems. For further improvement of water quality, some methods for changing the configuration of condensate demineralizer's resin bed have been examined. For example, these methods correspond to anion under layer and cation over layer. We have tested these methods by cold column tests. Furthermore, we have developed the newly anion exchange resin having higher efficiency and capacity for ...

2009-10-01

271

Synergistic effect of different phase on the photocatalytic activity of visible light sensitive silver antimonates  

British Library Electronic Table of Contents (United Kingdom)

We investigated phase transition of ilmenite-type AgSbO3 to pyrochlore by post-heat treatment and the synergy effect of the mixed phases of AgSbO3 on the photocatalytic activities to enhance the activities. The AgSbO3 with an ilmenite structure was prepared by a cation-exchange method. Phase transition from the ilmenite to pyrochlore occurred by proper control of post-heat treatment. The sample that was obtained by post-heat treatment of ilmenite-type AgSbO3 at 660^oC for 3h consisted of both of the ilmenite and pyrochlore phases, and the sample at 685^oC for 4h mainly consisted of the pyrochlore phase. Together with an increase in the ratio of the pyrochlore phase, the optical absorption spectra blue-shifted. The band gaps of single phases of the ilmenite and the pyrochlore were 2.4 and 2...

2010-01-01

272

Preliminary study on improvement of cementitious grout thermal conductivity for geothermal heat pump applications  

Energy Technology Data Exchange (ETDEWEB)

Preliminary studies were preformed to determine whether thermal conductivity of cementitious grouts used to backfill heat exchanger loops for geothermal heat pumps could be improved, thus improving efficiency. Grouts containing selected additives were compares with conventional bentonite and cement grouts. Significant enhancement of grout alumina grit, steel fibers, and silicon carbide increased the thermal conductivity when compared to unfilled, high solids bentonite grouts and conventional cement grouts. Furthermore, the developed grouts retained high thermal conductivity in the dry state, where as conventional bentonite and cement grouts tend to act as insulators if moisture is lost. The cementitious grouts studied can be mixed and placed using conventional grouting equipment.

1996-06-01

273

Optimum design of the Wolsung tritium removal facility  

Energy Technology Data Exchange (ETDEWEB)

Tritium removal from tritiated heavy water in a PHWR is the most effective way in reducing workers` internal dose and radioactivity emissions from Wolsong NPP. The optimum design of the Wolsung TRF(Tritium Removal Facility) was carried out using an approximate short-cut method with an assumption that the TRF, designed to extract 8 MCi per year of elemental tritium from a heavy water feedstream, uses Liquid Phase Catalytic Exchange (LPCE) front-end process and Cryogenic Distillation (CD) process. 19 refs., 6 figs., 2 tabs. (author).

1996-08-01

274

Optimum design of the Wolsung tritium removal facility  

International Nuclear Information System (INIS)

Tritium removal from tritiated heavy water in a PHWR is the most effective way in reducing workers' internal dose and radioactivity emissions from Wolsong NPP. The optimum design of the Wolsung TRF(Tritium Removal Facility) was carried out using an approximate short-cut method with an assumption that the TRF, designed to extract 8 MCi per year of elemental tritium from a heavy water feedstream, uses Liquid Phase Catalytic Exchange (LPCE) front-end process and Cryogenic Distillation (CD) process. 19 refs., 6 figs., 2 tabs. (author).

1996-01-01

275

Introduction of energy saving type air conditioner  

Energy Technology Data Exchange (ETDEWEB)

It is reported that due to the large demand for electricity in Japanese homes and given the fact that the energy consumption rate of air conditioners to the total energy consumption rate in an average home exceeds 20%, an energy saving-type room air conditioner is essential, also for environmental reasons. Japanese customers ranked high running costs as a major drawback of conventional equipment. Toshiba started developing the first generation energy saving air conditioners in 1993. Improvements to the concept were made and the 1995 model offers a heating COP of 4.65 and a cooling COP of 4.3 at rated conditions, an improvement of more than 30% compared to the conventional model. Various component improvements have led to this high performance including the indoor fan design, a DC compressor motor and inverter using digital sampling, advanced (PMV) control technology, and compact heat exchangers. The latest feature is ...

1996-07-01

276

Condenser replacement at Unterweser nuclear power station  

International Nuclear Information System (INIS)

In spite of extensive cooling water studies premature damage due to corrosion occurred on the CuZn20Al condenser tubes. It was then decided to incorporate new titanium-tubed condensers during the annual overhauls of 1983 and 1985 and also take ameliorating measures up to the exchange of individual condensers. (orig.).

277

The numerical simulation on low-level radioactive waste water, low-temperature cooling water drained effect of implement from the Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

In this paper, we calculated the radioactive concentration distribution of radioactive waste water, the temperature distribution of drained cooling water and the effect of implement from the Daya Bay Nuclear Power Plant on nearby waters range, discussed and analysed some problems of computational results and computation with Alternating Direction Implicit Method (ADI). The contents of the article included: the establishment of two-dimension tidal current equation, radioactive waste water pollutant dispersion equation and cooling water heat convection diffusion equation, the numerical difference calculation model of tidal current field, concentration field as well as temperature field, effect impingement with ADI method, numerical calculation results. The result of research showed that: when the Daya Bay Nuclear Power Plant is on normal operation and after the ...

278

Influence of two systematic parameters on the geothermal heat pump system operation  

Energy Technology Data Exchange (ETDEWEB)

In order to match the output capacity of a geothermal heat pump system (GHPS) with the actual load requirement, research has been carried out in finding the influence of two systematic parameters, the water flow rate inside the condenser and the compressor input frequency on the GHPS operation. Experiments are done on a small-scale GHPS at the water flow rate ranging from 0.054 kg/s to 0.174 kg/s and the frequency from 30 Hz to 55 Hz. The analysis of the experimental data reveals the relationships among the compressor frequency, the water flow rate and other important parameters such as coefficient of performance (COP), heat capacity and compressor power input. The conclusions in the paper can serve as some guidance to the load adjustment of GHPS. (author)

2003-01-01

279

Shielding options for the ITER conceptual design  

Energy Technology Data Exchange (ETDEWEB)

Several shield options were analyzed for the ITER conceptual design to minimize the nuclear responses in the toroidal field (TF) coils. The total nuclear heating in the physics phase and the insulator dose in the technology phase are the most critical parameters in the design process. The first shield option has type 316 stainless steel and water shielding material. Steel and water also serve as structural material and coolant, respectively. The second option is similar to the first except that borated water is used instead of ordinary water. The other two options include a small layer of lead or boron carbide (B{sub 4}C) at the back of the shield. The last three shield options were considered to reduce the nuclear heating in the toroidal field coils relative to the steel/water shield. An optimization process was performed taking into ...

1989-10-01

280

Enhancement of convective heat transfer by using microencapsulated PCM slurry  

Energy Technology Data Exchange (ETDEWEB)

As a method to make use of a high latent heat of a liquid-solid phase change material in a confined convective heat transfer, a phase change material, lauric acid, was encapsulated in a tiny hollow sphere, and mixed with water, forming a slurry of microencapsulated phase-change material (MCPCM slurry). Four different sizes (200, 100, 50, and 25 {mu}m ID) of MCPCMs were tested in this study. Thermal characteristics of the pure lauric acid and lauric acid MCPCMs were tested by a differential scanning calorimeter. Viscosity of the slurries of water and the capsules was measured by a rotating viscometer. The slurries were also tested in a convective-heat-transfer-test apparatus. (author). 11 refs., 5 figs., 1 tab.

1998-11-01

281

Canadian R&D on oil-fired combustion systems  

Energy Technology Data Exchange (ETDEWEB)

This paper describes research and development presently being conducted on oil-fired space and tap water heating systems by the Advanced Combustion Technology Group, CCRL/ERL/CANMET, in Ottawa, Canada. The presentation will focus on R&D activities at CCRL in support of the Canadian Oil Heat Association (COHA) and of the energy policy initiatives of Natural Resources Canada. Progress will be reported on activities to develop suitable oil-fired integrated systems to satisfy the low energy demands of new homes. The utilization of fuzzy logic-based control heating systems including fan coils for a complete range of old and new North American housing will be discussed. Additional activities to be discussed in the presentation will relate to the development of appropriate seasonal efficiency standards for complex integrated space/water heating systems, as well as ...

1996-07-01

282

Thermal-hydraulic limitations on water-cooled limiters  

Energy Technology Data Exchange (ETDEWEB)

An assessment of the cooling requirements for fusion reactor components, such as the first wall and limiter/divertor, was carried out using pressurized water as the coolant. In order to establish the coolant operating conditions, a survey of the literature on departure from nucleate boiling, critical heat flux, asymmetrical heating and heat transfer augmentation techniques was carried out. The experimental data and the empirical correlations indicate that thermal protection for the fusion reactor components based on current design concepts can be provided with an adequate margin of safety without resorting to either high coolant velocities, excessive coolant pressures, or heat transfer augmentation techniques. If, however, the future designs require heat transfer enhancement techniques, experimental verification would be necessary since no data on ...

1984-08-01

283

Thermal-hydraulic limitations on water-cooled fusion reactor components  

Energy Technology Data Exchange (ETDEWEB)

An assessment of the cooling requirements for fusion reactor components, such as the first wall and limiter/divertor, was carried out using pressurized water as the coolant. In order to establish the coolant operating conditions, a survey of the literature on departure from nucleate boiling, critical heat flux, asymmetrical heating and heat transfer augmentation techniques was carried out. The experimental data and the empirical correlations indicate that thermal protection for the fusion reactor components based on conventional design concepts can be provided with an adequate margin of safety without resorting to either high coolant velocities, excessive coolant pressures, or heat transfer augmentation techniques. If, however, the future designs require unconventional shapes or heat transfer enhancement techniques, experimental verification would be necessary ...

1986-01-01

284

Thermal-hydraulic limitations on water-cooled fusion reactor components  

Energy Technology Data Exchange (ETDEWEB)

An assessment of the cooling requirements for fusion reactor components, such as the first wall and limiter/divertor, was carried out using pressurized water as the coolant. In order to establish the coolant operating conditions, a survey of the literature on departure from nucleate boiling, critical heat flux, asymmetrical heating and heat transfer augmentation techniques was carried out. The experimental data and the empirical correlations indicate that thermal protection for the fusion reactor components based on conventional design concepts can be provided with an adequate margin of safety without resorting to either high coolant velocities, excessive coolant pressures, or heat transfer augmentation techniques. If, however, the future designs require unconventional shapes or heat transfer enhancement techniques, experimental verification would be necessary ...

1987-01-01

285

Thermal-hydraulic limitations on water-cooled fusion reactor components  

International Nuclear Information System (INIS)

An assessment of the cooling requirements for fusion reactor components, such as the first wall and limiter/divertor, was carried out using pressurized water as the coolant. In order to establish the coolant operating conditions, a survey of the literature on departure from nucleate boiling, critical heat flux, asymmetrical heating and heat transfer augmentation techniques was carried out. The experimental data and the empirical correlations indicate that thermal protection for the fusion reactor components based on conventional design concepts can be provided with an adequate margin of safety without resorting to either high coolant velocities, excessive coolant pressures, or heat transfer augmentation techniques. If, however, the future designs require unconventional shapes or heat transfer enhancement techniques, experimental verification would be necessary ...

1986-12-07

286

Use of solar assisted geothermal heat pump and small wind turbine systems for heating agricultural and residential buildings  

Energy Technology Data Exchange (ETDEWEB)

The main objective of the present study is twofold: (i) to analyze thermal loads of the geothermally and passively heated solar greenhouses; and (ii) to investigate wind energy utilization in greenhouse heating which is modeled as a hybrid solar assisted geothermal heat pump and a small wind turbine system which is separately installed in the Solar Energy Institute of Ege University, Izmir, Turkey. The study shows 3.13% of the total yearly electricity energy consumption of the modeled system (3568 kWh) or 12.53% of the total yearly electricity energy consumptions of secondary water pumping, brine pumping, and fan coil (892 kWh) can be met by using small wind turbine system (SWTS) theoretically. According to this result, modeled passive solar pre heating technique and combined with geothermal heat pump system (GHPS) and SWTS can be economically preferable to the ...

2010-01-15

287

Prediction of thermal conductivity of ethylene glycol-water solutions by using artificial neural networks  

British Library Electronic Table of Contents (United Kingdom)

The objective of this study is to develop an artificial neural network (ANN) model to predict the thermal conductivity of ethylene glycol-water solutions based on experimentally measured variables. The thermal conductivity of solutions at different concentrations and various temperatures was measured using the cylindrical cell method that physical properties of the solution are being determined fills the annular space between two concentric cylinders. During the experiment, heat flows in the radial direction outwards through the test liquid filled in the annual gap to cooling water. In the steady state, conduction inside the cell was described by the Fourier equation in cylindrical coordinates, with boundary conditions corresponding to heat transfer between the solution and cooling water. ...

2009-01-01

288

Straw-fuelled heating power stations in Denmark; Strohheizkraftwerke in Daenemark  

Energy Technology Data Exchange (ETDEWEB)

During the past 15 years, 60 straw-fuelled and 25 wood-fuelled district heating stations were commissioned in Denmark, as well as 6 biomass-fuelled heating power stations. All of these plants are equipped with high-pressure boilers, heat exchangers for district heating, and steam turbines with generators. Today, 5 percent of the total energy consumed is provided by biomass fuels. With the new taxes on carbon dioxide emissions and measures to promote renewable energy sources, a 15 percent share can be expected soon. (orig/SR) [Deutsch] In Daenemark wurden in den letzten 15 Jahren 60 strohbefeuerte und 25 holzbefeuerte Fernwaermewerke in Betrieb genommen. Dazu sind in den letzten Jahren 6 biomassebefeuerte Heizkraftwerke gekommen. Alle Anlagen haben Hochdruckkessel, Waermetauscher fuer Fernwaerme und Dampfturbinen mit Generatoren. Heute werden in Daenemark 15 Prozent des ...

1996-12-31

289

A thermochemical hydrogen production system based on a high-temperature fusion reactor blanket  

International Nuclear Information System (INIS)

A conceptual fusion synfuel production system has been developed with the unique features of: (1) a fusion blanket producing high-temperature (1250"0C) process heat, and (2) the GA sulfur-iodine thermochemical cycle. The system incorporates a two-zone blanket which achieves a tritium breeding ratio of 1.1 while delivering a high fraction (30%) of the fusion heat at high temperatures (1250"0C). The multiple barriers to tritium permeation in the blanket design permit the hydrogen product to meet 10CFR20 regulatory requirements without stringent requirements on the tritium recovery systems. A ceramic heat exchanger, incorporating SiC tubes and headers to contain the process stream and a cooled, Inconel 718 pressure shell to contain the helium, was designed for transferring the heat from the high-temperature coolant to the process. A good heat-line match of the ...

1983-04-26

290

Low temperature humidification dehumidification desalination process  

Energy Technology Data Exchange (ETDEWEB)

The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling water. The ...

2006-03-01

291

Low temperature humidification dehumidification desalination process  

International Nuclear Information System (INIS)

The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling water. The ...

2006-03-01

292

Inherent safe heat removal in advanced medium-sized high-temperature reactors  

International Nuclear Information System (INIS)

One of the main points for the inherent safety of a pebble bed high temperature reactor (HTR) is to guarantee the safe removal of the after-heat in case of a break-down of all active cooling systems like heat-exchangers or liner-cooling. This will be necessary because it is well known today that graphite pebble bed fuel elements stay intact, if the accident temperature is below 1600 deg. C. Therefore the heat must be taken out of the reactor system by passive, natural law heat-transfer mechanism so that the maximum fuel temperature stays below the specified limit. Today medium-sized HTRs with a power of 750 MW_t_h and more (TGTR-300, HTR 500) reach temperatures of more than 2400 deg. C in small parts of the core in such hypothetical accidents. A possible way to realize the inherent safe heat removal in advanced medium-sized HTRs is to change the form of the core. Instead of ...

1990-04-01

293

Boiling flow instabilities in parallel channels with enhanced heat transfer  

International Nuclear Information System (INIS)

During the last two decades, the demand for higher heat transfers in the heat exchangers has kept increasing. These high heat transfer rates can be obtained by using two-phase flows, or heat transfer augmented surfaces, or in some cases, both. Thus, the boiling flows and the associated two-phase flow instabilities have been studied by many investigators. Most of the work in boiling flows has been concentrated on single channel upflow systems or on parallel channel systems with plain heat transfer surfaces. The boiling flow instabilities in multi-channel systems should be covered to a greater extent, studying the effects of various parameters, such as inlet and outlet restriction, mass flow rates, the property variations, heat transfer coefficients, equal and unequal heat inputs on the stability. Also, the mathematical ...

1985-10-01

294

The use of supplementary firing in an externally-fired combined cycle power plant  

Energy Technology Data Exchange (ETDEWEB)

The most developed systems for the generation of electricity from coal are the Integrated coal Gasification Combined Cycle (IGCC) and the Pressurized Fluidized Bed Combustion (PFBC) system. They both represent state-of-the-art technology and provide electric power at 41-46% LHV efficiency. However, the high level of complexity leads to lower reliability and higher costs. A simpler system, based on a coal-fired steam boiler integrated with a gas turbine, has been proposed. In such a plant, known as the externally fired combined cycle (EFCC), compressed air is heated indirectly in a heat exchanger located in the coal furnace. The hot air is then expanded in a turbine, and the exhaust is passed on to the coal furnace as preheated combustion air. Steam produced in the boiler generates additional power in a steam turbine. The exclusion of coal combustion products from the gas turbine avoids hot gas clean-up and turbine blade ...

1997-12-31

295

GeoExchange market development : the US experience  

Energy Technology Data Exchange (ETDEWEB)

In 1994, the United States Department of Energy, the United States electric utilities and the geothermal heat pump (GeoExchange) industry formed a non-profit collaborative effort called the Geothermal Heat Pump Consortium (GHPC). The objectives were the reduction and/or elimination of 1.5 million metric tons of carbon equivalent per year and making geothermal heat pumps a significant part of the Heating Ventilation Air Cooling (HVAC) industry. Federal funding of 35 million dollars over six years was matched by 65 million dollars of private sector funds to attain these objectives and create a self-sustainable GeoExchange market. The major accomplishments of this endeavour, as well as the lessons learned were presented in this paper. The infrastructure was strengthened, first cost was reduced, and awareness of the technology was increased over the past six years ...

2000-12-01

296

Externally fired combined cycle. Potential and state of the art (Pt. 2); Extern gefeuerter Gasturbinenprozess. Potenziale und Entwicklungsstand (T.2)  

Energy Technology Data Exchange (ETDEWEB)

The externally fired combined cycle (EFCC) process utilises a high temperature heat exchanger to transfer the heat of a dirty flue gas to a clean working medium. In comparison to other combined cycle concepts, like integrated gasification combined cycle or pressurized pulverized coal combustion, the problems of hot gas cleaning are avoided. The first part of the publication (BWK 5/02) deals with the possible concepts and the efficiency potential of the externally fired combined cycle. The applicability of metallic and ceramic heat exchanger materials are discussed. The second part summarizes the state of the art and presents the basic design of a ceramic heat exchanger. [German] Der extern gefeuerte Gasturbinenprozess arbeitet mit einem Waermeuebertrager, um ein Arbeitsmedium auf Gasturbineneintrittstemperatur zu erhitzen. Im Vergleich zu ...

2002-07-01

297

Externally fired combined cycle. Part 1. Potential and state of the art; Extern gefeuerter Gasturbinenprozess. Teil 1. Potenziale und Entwicklungsstand  

Energy Technology Data Exchange (ETDEWEB)

The externally fired combined cycle (EFCC) process utilises a high temperature heat exchanger to transfer the heat of a dirty flue gas to a clean working medium. In comparison to other combined cycle concepts, like integrated gasification combined cycle or pressurized pulverized coal combustion, the problems of hot gas cleaning are avoided. The first part of the publication deals with the possible concepts and the efficiency potential of the externally fired combined cycle. The applicability of metallic and ceramic heat exchanger materials are discussed. The second part (BWK 6/02) summarizes the state of the art and presents the basic design of a ceramic heat exchanger. (orig.) [German] Der extern gefeuerte Gasturbinenprozess arbeitet mit einem Waermeuebertrager, um ein Arbeitsmedium auf Gasturbineneintrittstemperatur zu erhitzen. Im ...

2002-07-01

298

Waste treatment process for removal of contaminants from aqueous, mixed-waste solutions using sequential chemical treatment and crossflow microfiltration, followed by dewatering  

Energy Technology Data Exchange (ETDEWEB)

In processes of this invention aqueous waste solutions containing a variety of mixed waste contaminants are treated to remove the contaminants by a sequential addition of chemicals and adsorption/ion exchange powdered materials to remove the contaminants including lead, cadmium, uranium, cesium-137, strontium-85/90, trichloroethylene and benzene, and impurities including iron and calcium. Staged conditioning of the waste solution produces a polydisperse system of size enlarged complexes of the contaminants in three distinct configurations: water-soluble metal complexes, insoluble metal precipitation complexes, and contaminant-bearing particles of ion exchange and adsorbent materials. The volume of the waste is reduced by separation of the polydisperse system by cross-flow microfiltration, followed by low-temperature evaporation and/or filter pressing. The water produced as filtrate is discharged if it ...

1994-01-01

299

Waste treatment process for removal of contaminants from aqueous, mixed-waste solutions using sequential chemical treatment and crossflow microfiltration, followed by dewatering  

Energy Technology Data Exchange (ETDEWEB)

In processes of this invention aqueous waste solutions containing a variety of mixed waste contaminants are treated to remove the contaminants by a sequential addition of chemicals and adsorption/ion exchange powdered materials to remove the contaminants including lead, cadmium, uranium, cesium-137, strontium-85/90, trichloroethylene and benzene, and impurities including iron and calcium. Staged conditioning of the waste solution produces a polydisperse system of size enlarged complexes of the contaminants in three distinct configurations: water-soluble metal complexes, insoluble metal precipitation complexes, and contaminant-bearing particles of ion exchange and adsorbent materials. The volume of the waste is reduced by separation of the polydisperse system by cross-flow microfiltration, followed by low-temperature evaporation and/or filter pressing. The water produced as filtrate is discharged if it ...

1994-11-22

300

Resuscitation of Salmonella enterica Serovar Typhimurium and Enterohemorrhagic Escherichia coli from the Viable but Nonculturable State by Heat-Stable Enterobacterial Autoinducer  

UK PubMed Central (United Kingdom)

Salmonella enterica serovar Typhimurium and enterohemorrhagic Escherichia coli were stressed by prolonged incubation in water microcosms until it was no longer possible...Full Text Available

2002-10-01

301

Resistance of Bacillus subtilis var. niger Spores Occluded in Water-insoluble Crystals to Three Sterilization Agents  

UK PubMed Central (United Kingdom)

The resistance to destruction of spores of Bacillus subtilis var. niger occluded in crystals of calcium carbonate and exposed to ethylene oxide and moist and dry heat...Full Text Available

1967-07-01

302

Environmental effects and energy efficiency in building design: A green building approach. Part 1, energy efficiency techniques. Research report  

Energy Technology Data Exchange (ETDEWEB)

;Contents: Energy Use; Building Fabric Performance; Ventilation and Infiltration; Passive Solar Design; Heating Systems and Controls; Hot and Cold Water Provision; and Lighting and Electrical Appliances.

1993-01-01

303

Environmental Effects and Energy Efficiency in Building Design: A Green Building Approach. Part 1, Energy Efficiency Techniques.  

Science.gov (United States)

Contents: Energy Use; Building Fabric Performance; Ventilation and Infiltration; Passive Solar Design; Heating Systems and Controls; Hot and Cold Water Provision; and Lighting and Electrical Appliances.

1993-01-01

304

40 CFR 63.321 - Definitions.  

Science.gov (United States)

...limited to, emission control devices, pumps, filters, muck cookers, stills, solvent tanks, solvent containers, water separators...facility that meets the conditions of § 63.320(g). Muck cooker means a device for heating perchloroethylene-laden...

2009-07-01

305

Safety System Design Concept and Performance Evaluation for a Long Operating Cycle Simplified Boiling Water Reactor  

Science.gov (United States)

The long operating cycle simplified boiling water reactor is a reactor concept that pursues both safety and the economy by employing a natural circulation reactor core without a refueling, a passive decay heat removal, and an integrated building for the reactor and turbine. Throughout the entire spectrum of the design basis accident, the reactor core is kept covered by the passive emergency core cooling system. The decay heat is removed by the conventional active low-pressure residual heat removal system. As for a postulated severe accident, the suppression pool water floods the lower part of the reactor pressure vessel (RPV) in the case when core damage occurs, and the in-vessel retention that keeps the melt inside the RPV is achieved by supplying the coolant. The containment adopts a parallel-double-steel-plate structure similar to a hull structure, which contains coolant between ...

2003-07-15

306

Water management studies in PEM fuel cells, Part I: Fuel cell design and in situ water distributions  

Energy Technology Data Exchange (ETDEWEB)

A proton exchange membrane fuel cell (PEMFC) must maintain a balance between the hydration level required for efficient proton transfer and excess liquid water that can impede the flow of gases to the electrodes where the reactions take place. Therefore, it is critically important to understand the two-phase flow of liquid water combined with either the hydrogen (anode) or air (cathode) streams. In this paper, we describe the design of an in situ test apparatus that enables investigation of two-phase channel flow within PEMFCs, including the flow of water from the porous gas diffusion layer (GDL) into the channel gas flows; the flow of water within the bipolar plate channels themselves; and the dynamics of flow through multiple channels connected to common manifolds which maintain a uniform pressure differential across all possible flow paths. These two-phase flow effects have been ...

2009-05-15

307

Diversity of Tropical Tree Seedling Responses to Drought  

British Library Electronic Table of Contents (United Kingdom)

ABSTRACT Drought is an important seedling mortality agent in dry and moist tropical forests, and more severe and frequent droughts are predicted in the future. The effect of drought on leaf gas exchange and seedling survival was tested in a dry-down experiment with four tree species from dry and moist forests in Bolivia. Seedlings were droughted and wilting stage and gas exchange were monitored. Drought led to a gradual reduction of photosynthesis and stomatal conductance over time, whereas respiration and photosynthetic water-use efficiency initially increased with drought and then declined. Seedlings gradually went through the different wilting stages, until they eventually died, but the trajectory differed for the four species. The strong relationship between wilting stage and photosynt...

2007-01-01

308

On the anatomy of the adsorption heat versus loading as a function of temperature and adsorbate for a graphitic surface  

British Library Electronic Table of Contents (United Kingdom)

In this paper we review and classify the various patterns of isosteric heat versus loading for adsorption of gases on graphitised thermal carbon black at temperatures ranging from below the 3D triple point to temperatures above it, but less than the 3D critical point. We have identified the features of heat curve and highlighted the microscopic origin of these features. The patterns vary with temperature and with the relative strength of the fluid-fluid interaction and solid-fluid interaction. For simple adsorptives (by simple we meant there is no strong association between fluid particles), the heat curve is typified by fluid-fluid attraction and layering phenomena. For adsorptives showing strong association such as water, ammonia and methanol, the heat curve essentially begins below the ...

2008-01-01

309

Materials selection for the US INTOR divertor collector plate  

Energy Technology Data Exchange (ETDEWEB)

The divertor collector plate in the INTOR reactor will be subjected to high heat, particle, and neutron fluxes, making it the most severely damaged torus component. The collector plate is composed of a protection plate, which is directly exposed to the particle flux, and a heat sink which provides support for the protection plate and carries the water coolant. The high-Z refractory metals have been considered for use as the protection plate material, and austenitic stainless steels and copper alloys have been considered as the heat sink material. Tungsten and Type 316 stainless steels have been selected for the protection plate and heat sink, respectively. The protection plate has a sputtering lifetime of 1.75 y at a 50% duty factor, while the heat sink is expected to last the lifetime of the reactor.

1981-01-01

310

Waste treatment process for removal of contaminants from aqueous, mixed-waste solutions using sequential chemical treatment and crossflow microfiltration, followed by dewatering  

Energy Technology Data Exchange (ETDEWEB)

It is an object of the claimed invention to combine chemical treatment with microfiltration process to treat groundwater, leachate from contaminated soil washing, surface and run-off waters contaminated with toxic metals, radionuclides and trace amounts of organics from variety of sources. The process can also be used to treat effluents from industrial processes such as discharges associated with smelting, mining and refining operations. Influent contaminants amenable to treatment are from a few mg/L to hundreds of mg/L. By selecting appropriate precipitation, ion exchange and adsorption agents and conditions, efficiencies greater than 99.9 percent can be achieved for removal of contaminants. The filtered water for discharge can be targeted with either an order of magnitude greater or lower than contaminant levels for drinking water.

1992-12-31

311

Photosynthesis responses to various soil moisture in leaves of Wisteria sinensis  

British Library Electronic Table of Contents (United Kingdom)

A study was conducted to determine the fitting soil moisture for the normal growth of two-year-old W. sinensis (Sims) Sweets by using gas exchange technique. Remarkable threshold values of net photosynthetic rate (Pn), transpiration rate (Tr) and water use efficiency (WUE) were observed in the W. sinensis leaves treated by various soil moisture and photosynthetic available radiation (PAR). The fitting soil moisture for maintaining a high level of Pn and WUE was in range of 15.3%?26.5% of volumetric water content (VWC), of which the optimal VWC was 23.3%. Under the condition of fitting soil moisture, the light saturation point of leaves occurred at above 800?mol?m?2?s?1, whereas under the condition of water deficiency (VWC, 11.9% and 8.2%) or oversaturation (VWC, 26.5%), the light saturatio...

2007-01-01

312

Alkylaldehyde-bisulfite adducts as cleavable surfactants  

British Library Electronic Table of Contents (United Kingdom)

Alkylaldehyde-bisulfite adducts with octyl, decyl, and dodecyl groups (CnS: n=8,10,12) were synthesized and the surface-active properties of the water-soluble compounds were compared. Exchange of the counter anions of C10S and C12S from sodium to tetramethylammonium solubilized them in water. The latter ammonium salt (C12S-QA) had surface activities as good as a classical surfactant, sodium dodecylsulfate, and dissociated promptly in weakly basic solution at room temperature to be a non-surfactant. It was also found that C12S-QA solubilized a hydrophobic substrate (solid), N,N-dimethyl-3-nitroaniline, in water and then separated it as a precipitate after alkali treatment.

2007-01-01

313

Reducing the breakdowns and energy consumption in pressure regulating stations by rationalizing the heating of gas  

Energy Technology Data Exchange (ETDEWEB)

Sigma 1) examines ways to reduce the number of breakdowns of pressure-regulating stations and to minimize the energy consumed in warming the gas, 2) determines the optimal gas temperatures upstream from the pressure reduction, and 3) shows the dependence of energy consumption upon the water dewpoint. The method of calculating the optimal input temperature relies on Mollier's diagram. Tables and nomographs for natural gas and water dewpoint at 19/sup 0/F and 580 psi (-7/sup 0/C and 4 MPa) are useful in achieving the desired gas temperatures. Heating the regulators' control valves is important.

1982-04-01

314

Application of automatic inspection system to nondestructive test of heat transfer tubes of primary pressurized water cooler in the high temperature engineering test reactor. Joint research  

International Nuclear Information System (INIS)

Heat transfer tubes of a primary pressurized water cooled (PPWC) in the high temperature engineering test reactor (HTTR) form the reactor pressure boundary of the primary coolant, therefore are important from the viewpoint of safety. To establish inspection techniques for the heat transfer tubes of the PPWC, an automatic inspection system was developed. The system employs a bobbin coil probe, a rotating probe for eddy current testing (ECT) and a rotating probe for ultrasonic testing (UT). Nondestructive test of a half of the heat transfer tubes of the PPWC was carried out by the automatic inspection system during reactor shutdown period of the HTTR (about 55% in the maximum reactor power in this paper). The nondestructive test results showed that the maximum signal-to-noise ratio was 1.8 in ECT. Pattern and phase of Lissajous wave, which were obtained for the heat transfer tube of ...

315

Radisson community heating systems: technical and economic comparison of options. Final report  

Energy Technology Data Exchange (ETDEWEB)

The study reported was conducted to evaluate water source community heat pump systems for possible installation to serve a number of homes which are to be constructed in the northeast section of Radisson, New York. Although specific sites and facilities have been evaluated, it is the intent of this study to be site specific only to the extent of climatic conditions. In other words, the results of this study should apply to any area with similar climate.

1981-12-01

316

On the feedwater heating in a steam generator of horizontal type  

International Nuclear Information System (INIS)

Design layout of horizontal steam generator (SJ) with a special feedwater heating surface (by a surface water economizer), designated for NPPs with WWER-1000 reactors, is suggested. The design enables to decrease sharply the difference between the temperatures of saturation and feedwater. Blowdown outlet is organized against PG face, which increases the efficiency of flowing. The suggested layout enables to decrease thermal stresses in structural units and PG metal content, as compared to the PGV-1000 steam generator.

1989-01-01

317

Markets for clean energy  

Wastenet

... The products can be categorised as glazed flat-plate collectors, evacuated glass-tube collectors, and unglazed plastic or low temperature collectors. Glazed flat-plate collectors and vacuum tubes are widely used for solar water heating and space heating systems in all types of buildings. Unglazed plastic collectors are used exclusively for lower temperature applications, such as outdoor swimming pools or the agrarian business. Flat-plate solar collectors are likely to ...

318

Guide to UK renewable energy companies 2001. 6. ed.  

International Nuclear Information System (INIS)

This 2001 edition of the guide to UK renewable companies and equipment and service providers presents summaries of the different industry sectors covering wind power, photovoltaics, solar water heating, geothermal heat pump, hydroelectric power, marine current and wave technology, bioenergy, power generation from landfill gas, energy from waste, and cogeneration. A UK company classification listing and index is provided along with listing of UK organisations and companies and an index of advertisers.

319

A method of producing a stabilizer of wash drilling muds  

Energy Technology Data Exchange (ETDEWEB)

A method is proposed for producing a stabilizer of wash drilling muds; by hydrolysis of polyacrylonitrile in an aqueous solution of alkaline agent with heating. To raise the heat resistance of the stabilizer, as the alkaline agent is used monosilicate of sodium, while the hydrolysis is done at a molar ratio of polyacrylonitrile, sodium monosilicate and water equal to 1.0:0.7-2.5:100, to a degree of hydrolysis of 25-40.

1981-01-01

320

Radiant heating and cooling, displacement ventilation with heat recovery and storm water cooling: An environmentally responsible HVAC system  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the design, operation, and performance of an HVAC system installed as part of a project to demonstrate energy efficiency and environmental responsibility in commercial buildings. The systems installed in the 2180 m{sup 2} office building provide superior air quality and thermal comfort while requiring only half the electrical energy of conventional systems primarily because of the hydronic heating and cooling system. Gas use for the building is higher than expected because of longer operating hours and poor performance of the boiler/absorption chiller.

1998-12-31

321

Mixed convection flow in a horizontal rectangular channel subjected to a horizontal thermal gradient  

British Library Electronic Table of Contents (United Kingdom)

This paper deals with a mixed convection water flow in a horizontal rectangular duct, uniformly heated from one lateral vertical wall and thermally insulated elsewhere. The supplied heat flux induces a secondary flow, which structure is constituted of one longitudinal roll in the considered aspect ratio (??=?1.9), embedded into a return flow of possibly large stream wise extension (up to twenty channel heights). Such situation induces helicoidal trajectories for the fluid flow particles, which contributes to a heat transfer enhancement compared to purely forced convection flow.

2011-01-01

322

Mixed convection flow in a horizontal rectangular channel subjected to a horizontal thermal gradient  

Science.gov (United States)

This paper deals with a mixed convection water flow in a horizontal rectangular duct, uniformly heated from one lateral vertical wall and thermally insulated elsewhere. The supplied heat flux induces a secondary flow, which structure is constituted of one longitudinal roll in the considered aspect ratio (? = 1.9), embedded into a return flow of possibly large stream wise extension (up to twenty channel heights). Such situation induces helicoidal trajectories for the fluid flow particles, which contributes to a heat transfer enhancement compared to purely forced convection flow.

2011-04-01

323

Application of the porous media model for the LWR process components  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: A porous media solution PORFLO has been developed for the 3-dimensional two-phase flow by describing the process facility in Cartesian or cylindrical coordinates. The local porosity fraction is applied for distinguishing the fluid filled volumes from the solid structures. The solid structure contribute the two-phase flow through the wall friction, flow area and heat transfer. Optionally the solid structure may contain primary liquid of steam generators, steam in the higher temperature and pressure to be condensed or electrical heating power. By using these optional boundary conditions three different process facilities have been analysed. The thermohydraulic solution based on 5-equation approach, where the conservation equations are solved for the liquid and gas (vapour) mass, mixture momentum (giving the velocity only for the mixture), liquid and gas energy, is described shortly. In addition to that the ...

2005-07-01

324

A study on convective heat transfer with microcapsulated lauric acid slurry in circular pipe  

Energy Technology Data Exchange (ETDEWEB)

The objective of the present study is to reveal thermal characteristic of microcapsulated lauric acid slurry in circular pipe. Test were performed with microcapsulated lauric acid slurry in a heating test section with a constant heat flux boundary condition. Local Nusselt number and the effective thermal capacity were measured. As the size of microcapsulated lauric acid were increased, local Nusselt number of microcapsulated lauric acid slurry were increased. The effective thermal capacity of microcapsulated lauric acid slurry was 0.5 times than it of water.

2003-07-01

325

Phytoplankton primary production in a eutrophic cooling water pond  

Energy Technology Data Exchange (ETDEWEB)

The effect of longer ice-free periods on the seasonal variation and total annual values of phytoplankton primary production was considered along with the efficiency and productivity of the phytoplankton communities at different water temperatures by constant light. The studied pond, Vasikkalampi, is located in the town Jvyaskyla in central Finland. The pond is slightly eutrophic and its water is used for cooling purposes by a 35 MW thermal powerplant. The cooling water is taken in the middle of the pond and it returns as heated effluent to the northern part, near the surface, about 100 m from the intake pipe. This circulation and warming of the water keeps the pond open throughout the year except during the coldest weeks in the winter when some parts freeze over. The increase of the water temperature was not sufficient to be optimal for photosynthesis in the ...

1984-01-01

326

Theoretical and experimental investigations of an externally fired combined cycle process with HT heat exchanger; Theoretische und experimentelle Untersuchungen zum extern befeuerten Gasturbinen-Kombiprozess mit Hochtemperatur-Waermetauscher  

Energy Technology Data Exchange (ETDEWEB)

This paper deals with the externally coal-fired combined cycle (EFCC). A process simulation for different configurations of the EFCC-process is carried out as well as an investigation of the effect of the key parameters such as the gas turbine inlet temperature and the compressor intake airflow. The results show a promising potential of the efficiency. One component of this combined gas and steam turbine cycle is a high temperature heat exchanger that has to withstand the extrem chemical and thermal operating conditions. Fibre reinforced ceramics and combinations of them with monolithic ceramics seem to be the most promising materials for this application. A cost estimating of the EFCC-process shows that a competitive operation should be possible. (orig.) [Deutsch] Die Ergebnisse der Prozesssimulationen weisen ein vielversprechendes Wirkungsgradpotential des extern kohlebefeuerten Gasturbinenprozesses auf. Der fuer dieses neue Kraftwerkskonzept ...

1996-12-31

327

Field experience with eddy current X-probes in CANDU steam generators and heat exchangers  

Energy Technology Data Exchange (ETDEWEB)

CANDU steam generators and heat exchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if not all of the functions of the other tube-testing eddy current probes, it can inspect each tube for all ...

2006-07-01

328

Field experience with eddy current X-probes in CANDU steam generators and heat exchangers  

International Nuclear Information System (INIS)

CANDU steam generators and heat exchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if not all of the functions of the other tube-testing eddy current probes, it can inspect each tube for all ...

2005-11-20

329

Factors determining the stainless steel decontamination efficiency for the steam generator heat exchanger tubes at NPPs with the WWERs  

International Nuclear Information System (INIS)

To raise the efficiency of the redox method and decrease the amount of radioactive wastes, a possibility of improving the decontamination process for NPP heat exchanger tubes made of stainless steel is studied. In the home practice the redox method of equipment decontamination is carried out as a multi-cycle process. In each cycle the surface is treated first with a permanganate alkaline solution ther with an oxalic acid solution, with a condensate washing-at between the treatments. Using samples cut out of the steam generator pipelines of the first and third power units of the Novovoronezh NPP the effect of the oXalic acid concentration, as well as washout time and conditions on the decontamination factor are studied. On the basis of analysis of the obtained data a conclusion is drawn that using oxalic acid of low concentrations and increasing its concentrations from cycle to cycle maximum decontamination factor values can be obtained at a ...

330

Environmental monitoring at Kahe Point, Oahu, Hawaii for OTEC pilot-plant development  

Energy Technology Data Exchange (ETDEWEB)

Two 40 MWe Ocean Thermal Energy Conversion (OTEC) Pilot Plant programs are in the initial phase of development near Kahe Point, Oahu, Hawaii. The two options being examined are: (1) a shelf-seated artificial island, connected via a causeway to Oahu, using stainless steel heat exchangers, with the thermal resource enhanced by effluent from a near-by power plant, ammonia working fluid and biocide (chlorine) cleaning; and (2) a shelf mount tower 1 mile off shore using submerged aluminum heat exchangers, R-22 working fluid, and slurry cleaning with biocide (chlorine) backup. Environmental Technical Requirements are described including: siting criteria; environmental design, and operational criteria; thermal resource evaluation and variability; physical, chemical, and biological data requirements; and regulatory requirements. Due to siting, design, and operational differences the proposed two pilot plant ...

1982-08-01

331

Corrosion resistant coatings for silicon carbide heat exchanger tubes -- Volume 3. Final report  

Energy Technology Data Exchange (ETDEWEB)

The development of a silicon carbide (SiC) heat exchanger is a critical step in the development of the Externally-Fired Combined Cycle (EFCC) power system. SiC is the only material that provides the necessary combination of resistance to creep, thermal shock, and oxidation. While the SiC structure materials provide the thermomechanical and thermophysical properties needed for an efficient system, the mechanical properties of the SiC tubes are severely degraded through corrosion by the coal combustion products. To obtain the necessary service life of thousands of hours at temperature, a protective coating is needed that is stable with both the SiC tube and the coal combustion products, resists erosion from the particle laden gas stream, is thermal shock resistant, adheres to SiC during repeated thermal shocks (start-up, process upsets, shut-down), and allows the EFCC system to be cost competitive. This demanding set of technical performance and ...

1996-06-07

332

Corrosion on stainless steel in high concentrated sulphuric acid under flow- and fatigue loading conditions. Stroemungs- und schwingungsbeeinflusste Korrosion von nichtrostenden Staehlen in konzentrierter Schwefelsaeure; Schlussbericht  

Energy Technology Data Exchange (ETDEWEB)

It was to be investigated why inexplicable cracking occurred in plain stainless austenitic steel pipes of heat exchangers in discrete sites of the inner surface exposed to acid even with anodic corrosion protection, and what countermeasures must be taken. The following materials were investigated: X 6 CrNiTi 18 10 and X 6 CrNiMoTi 17 12 2. The influence of mechanical vibrations on passive film formation and destruction was investigated in unconstrained pipes and pipes constrained at one end in conditions of anodic protection at frequencies of 0 to 160 Hz and temperatures of 98 to 130 degrees Centigrade in 98% sulphuric acid. The authors were unable to reconstruct the cracks observed in practical operation in anodically protected heat exchanger pipes of stainless austenitic steel. (orig./MM). 5 refs., 2 tabs., 71 figs.

1990-09-20

333

Effect of total pressure on sulfur capture of Ca-ion exchanged coal; Kaatsu jokenka ni okeru Ca-tanjitan no datsuryu koka  

Energy Technology Data Exchange (ETDEWEB)

In relation to coal gasification and combustion under high pressure as highly efficient coal utilization, the effect of total pressure and sintering on the SO2 capture ability of Ca-ion exchanged coal and other desulfurizing agents were studied. In experiment, specimens were filled into a small pressurized reactor to heat them under high-pressure N2 atmosphere. After the completion of combustion reaction of char at 850{degree}C, SO2, CO2 and CO gases were measured at an outlet while flowing SO2/N2. As the experimental result, all of the S content in Ca-ion exchanged coal was not absorbed by Ca content in coal during pyrolysis and combustion, resulting in discharge of 36% of the S content. Since Ca-ion exchanged coal is fast in combustion reaction, most of the S content was desulfurized by coal ash. The ash content yielded from Ca-ion exchanged coal was more excellent in SO2 capture ...

1996-10-28

334

The reduction of feedwater iron by using absorption characteristics of cation exchange resins for BWR condensate demineralizers  

International Nuclear Information System (INIS)

Iron concentration control in feedwater is one of the most important subjects in water chemistry. Especially for the BWR plants without 100% flow volume of hollow fiber filter (HFF), rather high iron concentration in feedwater is one of the big issues as this causes relatively high radiation dose rate in drywell area. Cation exchange resins especially used in the plants with partial flow rate of HFF are expected to have the important role of capturing iron in feedwater. For this purpose, we have investigated the effective method for using iron absorption characteristics of cation exchange resin. The Cation-Over Layer method (COL) in condensate demineralizers (CD) effectively utilizes these characteristics. In order to demonstrate a performance of the cation overlay method, we had applied this method for three CD vessels at Fukushima Daiichi NPP Unit 3 for testing purpose. The result of this actual plant test indicated that ...

2009-10-01

335

Multiple Ion Exchange Column Tests for Technetium Removal from Hanford Tank Waste Supernate  

Science.gov (United States)

Five cycles of loading, elution, and regeneration were performed to remove technetium from a Hanford waste sample retrieved from Tank 241-AW-101 using SuperLig 639 resin. The waste sample was diluted to 4.95 M Na plus and then was processed to remove 137Cs through dual ion exchange columns each containing 15 mL of SuperLig 644. To remove 99Tc, the cesium decontaminated solution was processed downwards through two ion exchange columns, each containing 12 mL of SuperLig 639 resin. The columns, designated as lead and lag, each had an inside diameter of 1.45 cm and a height of 30 cm. The columns were loaded in series, but were eluted and then regenerated separately. The average technetium loading for the cycles was 250 BV at 10 percent breakthrough. There was no significant difference in the loading performances among the five cycles. The percent removal of 99Tc was greater than 99.94 percent and the average decontamination factor (DF) was ...

2004-02-27

336

Numerical study on the heat transfer to CO_2 flowing upward in a heated vertical tube at supercritical pressure  

International Nuclear Information System (INIS)

Full text of publication follows: As the coolant experiences no phase change in the core, SCWRs, unlike LWRs, cannot use design criteria based on the critical heat flux concept. The commonly accepted practice in SCWRs is to specify cladding temperature limits that must be met during transient and accident events. Therefore for the design of the SCWR, it is very important to predict the heat transfer coefficient to the supercritical water coolant with great accuracy. Our recent study focuses on the critical issue of measuring heat transfer to supercritical water at prototypical SCWR conditions and to develop the tools to predict the SCWR thermal behavior. A heat transfer test loop using a surrogate fluids, CO_2, is under construction. The reason of using CO_2 instead of water is that (i) valuable insight of the physical phenomena can be ...

2005-10-02

337

Wind loss prevention for open cavity solar receivers  

Energy Technology Data Exchange (ETDEWEB)

Apparatus for minimizing thermal loss in a windowless, open cavity solar receiver due to airflow at the receiver aperture includes means for deflecting wind away from the cavity opening such that flow stream reattachment occurs away from the receiver aperture to provide a dead air zone at the cavity opening. This prevents turbulent-mixing airflow exchange between ambient air and heated air within the solar receiver. The wind deflector apparatus includes either a passive annular deflection foil at the receiver aperture, or an active device for producing an outwardly projected air jet at the receiver aperture.

1982-01-26

338

Tube bundle for a heat exchanger  

International Nuclear Information System (INIS)

The tube bundle arrangement is suitable as reheating section of a steam generator in combination with a gas-cooled reactor. For any high-temperature section with a straightline type tube bundle, there is one inlet and one outlet collecting main; these two are arranged one opposite to the other and diametrically to the tube bundle. There are a number of lines from the inlet collecting main to the outlet collecting main; these lines are arranged axially one on top of the other and run around the tube bundle helically several times. (GL) 891 GL/GL 892 MB.

339

Standard radiation monitoring at Sendai nuclear power station  

International Nuclear Information System (INIS)

Standard radiation monitoring has been conducted at Sendai nuclear power station for the purpose of estimation of 'source activity' during refueling outage and evaluation of countermeasures to reduce dose rate. Selected objects of the monitoring are radiation dose rate at maintenance area, radiation field at each equipment and piping, coolant chemistry and plant operation condition. Monitored data indicates that 'source activity' variation can be estimated to some extent using influential factors, and that evaluation of change of loose crud activity, which is presumed to be represented by the dose rate at letdown heat exchanger, is necessary to further explain change in radiation field at main work area. (author).

340

SM-2--HORIZONTAL STEAM GENERATOR ANALYSIS  

Science.gov (United States)

ABS>A horizontal steam generator design for the SM-2 was lysis to determine the per formance of such a steam generator under steady state operating conditions and during load transients, The configuration for this design is a two- drum unit consisting of a heat exchanger unit and separator drum interconnected by integral riser and downcomer. An analog computer was used to analyze the steam generator behavior Wring load transients. The effect of various design changes on the response of the steam generator to step chages in load was determined. The horizontal steam generator design was compared to the existing vertical steam generator design for weight, size, price, and performance. (auth)

1959-11-01

341

Protective oxides in coal-fired combined cycle power systems  

Energy Technology Data Exchange (ETDEWEB)

In most industrial processes operating at elevated temperatures, protective oxide layers perform a vital duty in protecting the underlying metallic alloys from process gases. Coal-fired combined cycle power generation systems present a number of process conditions in which the properties of the protective oxide layers are particularly important. This paper discusses two of these particular conditions: (1) `erosion/corrosion` of in-bed heat exchanger tubing and (2) thermal cycling of hot gas path components. For both these situations, the desirable properties of protective scales are outlined. The behaviour of scales in practice are highlighted. 33 refs., 6 figs., 2 tabs.

1995-12-31

342

Preparation of [[sup 131]I]lipiodol as a hepatoma therapeutic agent  

Energy Technology Data Exchange (ETDEWEB)

An isotopic exchange method was used to label lipiodol with [sup 131]I. The labelling efficiency was > 92.5%, and the radiochemical purity of [[sup 131]I]lipiodol was above 98% as determined by ITLC. The influencing factors e.g. the heating temperature, reaction, pH and storage conditions were studied and the optimum conditions were determined. In a pilot study injecting [[sup 131]I]lipiodol for the treatment of hepatoma, about 70% of hepatoma patients had a response to the treatment with a reduction of [alpha]-fetoprotein and decrease of hepatoma sizes. The overall median survival was 9 months (range 2-17 months). (author).

1992-12-01

343

Operating experience with condenser tubes made from copper alloys and new developments; Betriebserfahrungen mit Kondensatorrohren aus Kupferlegierungen und aktuelle Entwicklungen  

Energy Technology Data Exchange (ETDEWEB)

Copper alloys are a suitable tubing material for turbine condensers and heat exchangers. Due to problems with corrosions copper alloys increasingly are displaced by high-grade steel and titanium. Blockages and surface formation in the pipes, disturbance of the oxide coating formation, erosion and quality faults with the production are the causes for the corrosion. In the contribution under consideration counter measures are designated for the solution of the problems with corrosions. The application limits for different copper alloys are designated. Recommendations for the optimized operation are given.

2008-07-01

344

Application of wavelet analysis to signal processing methods for eddy-current test; ueburetto kaiseki no kadenryushinshoho heno tekiyo  

Energy Technology Data Exchange (ETDEWEB)

This study deals with the application of wavelet analysis to detection and characterization of defects from eddy-current and ultrasonic testing signals of a low signal-to-noise ratio. Presented in this paper are the methods for processing eddy-current testing signals of heat exchanger tubes of a steam generator in a nuclear power plant. The results of processing eddy-current testing signals of tube test pieces with artificial flaws show that the flaw signals corrupted by noise and/or non-defect signals can be effectively detected and characterized by using the wavelet methods. (author)

1998-12-15

345

Angular scattering in electron capture and loss D/sup -/ beam formation processes  

Energy Technology Data Exchange (ETDEWEB)

The development of high energy (> 150 keV) neutral beams for heating and fueling magnetic fusion devices depends on the ability to produce well-collimated negative ion beams. The double capture charge-exchange technique is a known, scalable method. In order to maximize the overall efficiency of the process and to achieve the desired beam characteristics, it is necessary to examine the optical qualities of the beams as well as the total efficiency of beam production. A combined modeling and experimental study of the angular scattering effects in negative ion formation and loss processes has therefore been undertaken.

1980-01-01

346

A review of the behaviour of alloy 800 in liquid sodium  

International Nuclear Information System (INIS)

Although there is service experience of Alloy 800 as tubing for superheaters in conventional and nuclear (HTR) power stations and in PWR heat exchangers, there is no corresponding service experience in sodium-cooled fast reactor steam generators. However, some limited experimental studies have been made of corrosion behaviour, and of possible structure modifications and effects on mechanical properties which occur during exposure of this material to a high temperature sodium environment, and these are summarised in the paper. It is concluded that further work needs to be done before Alloy 800 can be confidently endorsed for use as tubing in fast reactor steam generators. (author).

347

Transient burnout in flow reduction condition  

International Nuclear Information System (INIS)

A transient flow reduction burnout experiment was conducted with water in a uniformly heated, vertically oriented tube. Test pressures ranged from 0.5 to 3.9 MPa. An analytical method was developed to obtain transient burnout conditions at the exit. A simple correlation to predict the deviation of the transient burnout mass velocity at the tube exit from the steady state mass velocity obtained as a function of steam-water density ratio and flow reduction rate. The correlation was also compared with the other data. (author).

348

Means for deriving hydrolized polyacrylonitrile  

Energy Technology Data Exchange (ETDEWEB)

A method is proposed for deriving hydrolized polyacrylonitrile from a water-based alkali solution. This process is meant to improve the thermal stability of clay drilling solutions by employing the hydrolized product to treat aliphatic non-water-soluble C/sub 8/-C/sub 16/ spirits in an organic dispersant during the presence of acidity and while the solution is being heated.

1982-01-01

349

Direct measurements of secondary water inventory of steam generator PGV-213 in operation  

Energy Technology Data Exchange (ETDEWEB)

Results of weight measurement of PGV-213 steam generator during filling in, heating-up and power increase are described. Special measurement system based on stress gauges has been developed. Method of derivation of secondary water inventory is described. Comparison of the data for two steam generators prove accuracy of the measurements. (orig.). 1 refs.

1997-12-31

350

Climates of the oceans  

Energy Technology Data Exchange (ETDEWEB)

''Climates of the Oceans'' deals with the atmosphere over the world oceans and provides a treatment not only of the climatic elements such as temperature, pressure, wind, precipitation etc., but also of the circulation of the atmosphere and its changes throughout the year. The connection between sea and overlying air is examined through studies of the water and heat balance. Numerous maps and tables illustrate the elements and their fluctuations over the water and on islands and coasts.

1984-01-01

351

The questions of liquid metal two-phase flow modelling in the FBR core channels  

International Nuclear Information System (INIS)

The two-fluid model representation for calculations of two-phase flow characteristics in the FBR fuel pin bundles with liquid metal cooling is presented and analysed. Two conservation equations systems of the mass, momentum and energy have been written for each phase. Components accounted the mass-, momentum- and heat transfer throughout the interface occur in the macro-field equations after the averaging procedure realisation. The pattern map and correlations for two-fluid model in vertical liquid metal flows are presented. The description of processes interphase mass- and heat exchange and interphase friction is determined by the two-phase flow regime. The opportunity of the liquid metal two-phase flow regime definition is analysed. (author)

2000-06-01

352

Oak Ridge Research Reactor. Quarterly report, July, August, and September 1984  

Energy Technology Data Exchange (ETDEWEB)

The ORR operated at an average power level of 29.7 MW for 85.3% of the time during this period. The reactor was shut down on fifteen occasions, nine of which were unscheduled. Reactor downtime needed for refueling and checks was normal. The reactor remained available for operation 88.3% of the time. Special tests completed during the quarter included: (1) transfer of LEU fuel elements CLE-202 and NLE-201 from core positions B-9 and B-2 to core positions C-5 and C-6 for continued operation; and (2) calculation of maximum heat flux in LEU elements CLE-201 and NLE-202 in core positions A-2 and A-8. In-service inspections included inspections of ORR decay tank, primary heat exchanger No. 4, and the 24-in. strainer.

1985-03-01

353

Modeling and control of a novel heat exchange reactor, the Open Plate Reactor  

British Library Electronic Table of Contents (United Kingdom)

A new chemical reactor, the Open Plate Reactor, is being developed by Alfa Laval AB. It combines good mixing with high heat transfer capacity into one operation. With the new concept, highly exothermic reactions can be produced using more concentrated reactants. A nonlinear model of the reactor is derived and a control system is developed. For temperature control a cooling system is designed and experimentally verified, which uses a mid-ranging control structure to increase the operating range of the hydraulic equipment. A Model Predictive Controller is proposed to maximize the conversion under hard input and state constraints. An extended Kalman filter is designed to estimate unmeasured concentrations and parameters. Simulations show that the designed control system gives high conversion ...

2007-01-01

354

Flow visualization II Proceedings of the Second International Symposium, Bochum, West Germany, September 9-12, 1980  

Energy Technology Data Exchange (ETDEWEB)

Applications, techniques, instrumentation, and interpretation of flow visualization are discussed. Methods of using flow visualization for the examination of combustion in furnaces, heat transfer with heat exchangers, and in fluid engines are explored, along with flow visualization in food processing, steel-casting, and process engineering. Further attention is given to pipe and channel flow, flow separation in laminar flow and around oscillating airfoils, wakes and vortices, supersonic flow and shock waves, and stratified flow and oceanography. The visualization of boundary layers is considered for various conditions, and applications for multiphase flow, rheology, and medical problems are detailed. Oil film, dry-surface coating, chemical, fluorescent, and minituft methods are presented, as well as the use of tracers, optical techniques, strobe lights, lasers, computerized data acquisition, and hot-wire anemometry.

1982-01-01

355

Market assessment for the fan atomized oil burner  

Energy Technology Data Exchange (ETDEWEB)

The market potential for the fan atomized burner (FAB) in water and space heating applications was examined. The major findings of the study are as follows. (1). The FAB`s low-input capability allows development of oil-fired room heaters and wall furnaces, a new market area for oil heat. (2). Among conventional oil-fired products, furnaces will benefit most from the burner`s low input capability due to (1) their quick delivery of heat and (2) their more prevalent use in warmer climates and smaller homes. (3). The greatest potential for increased product sales or oil sales exists in the use of the burner with new products (i.e., room heaters). Sales of boilers and direct-fired water heaters are not likely to increase with the use of the burner. (4). Acceptance of the burner will be dependent on proof of reliability. Proof of better reliability than conventional burners would ...

1996-07-01

356

Interface heat transfer of horizontal co-current liquid-liquid stratified flow  

International Nuclear Information System (INIS)

Co-current stratified flow of liquid metal and water was investigated in a horizontal rectangular channel. Position of the interface pressure drop and direct contact heat transfer between these immisci ble liquids were measured in a fully developed flow. A turbulence model was proposed to explain the experimental results considering that the turbulence is damped near the liquid-liquid interface by surface tension. The analytical results showed good agreement with the experimental ones. Main results are that (1) position of the interface mainly depends on the flow rate ratio of both liquids, that (2) the pressure drop is approximately proportional to square of the average velocity of water, and that (3) heat transfer rate at direct contact interface is several times higher than that of co-current flow separated by a thin solid plate. (author).

1980-01-01

357

Proceedings of the 1996 oil heat technology conference and workshop  

Energy Technology Data Exchange (ETDEWEB)

This Conference is a key technology transfer activity supported by the ongoing Combustion Equipment Technology (Oil-Heat R and D) program at BNL, and is aimed at providing a forum for the exchange of information among international researchers, engineers, manufacturers, and marketers of oil-fired space-conditioning equipment. The objectives of the Conference were to: identify and evaluate the state-of-the-art and recommend new initiatives for higher efficiency, a cleaner environment, and to satisfy consumer needs cost-effectively, reliably, and safely; and foster cooperation among federal and industrial representatives with the common goal of sustained national economic growth and energy security via energy conservation. The 1996 Oil Technology Conference comprised: (a) fourteen technical papers, and (b) four workshops which focused on mainstream issues in oil-heating technology, namely: oilheat research agenda forum; fan ...

1996-07-01

358

Proceedings of the 1995 oil heat technology conference and workshop  

Energy Technology Data Exchange (ETDEWEB)

This report documents the Proceedings of the 1995 Oil Heat Technology Conference and Workshop, held on March 22-23 at Brookhaven National Laboratory (BNL), and sponsored by the U.S. Department of Energy - Office of Building Technologies (DOE-OBT), in cooperation with the Petroleum Marketers Association of America. This Conference, which was the ninth held since 1984, is a key technology transfer activity supported by the ongoing Combustion Equipment Technology (Oil-Heat R&D) program at BNL, and is aimed at providing a forum for the exchange of information among international researchers, engineers, manufacturers, and marketers of oil-fired space-conditioning equipment. The objectives of the Conference were to: (1) Identify and evaluate the state-of-the-art and recommend new initiatives for higher efficiency, a cleaner environment, and to satisfy consumer needs cost-effectively, reliably, and safely; (2) Foster ...

1995-04-01

359

Heat transfer augmentation due to surface radiative exchange effect of internal fins in an annulus  

International Nuclear Information System (INIS)

Heat transfer augmentation due to surface radiation in an annulus with fins was investigated both theoretically and experimentally for fully developed laminar flow. The system considered in the present study was an array of axially internal and straight fins attached to the outer tube wall. Analytical solutions were given for 4, 8, 16, 24, 32 fins and for the ratios of the fin height to the passage clearance, 0, 0.2, 0.4, 0.5, 0.6, 0.8. The experiments were performed with air as the working fluid for radius ratio of 1.45, 16 fins and for Reynolds numbers ranging from 500 to 2000. The numerically predicted results of the convective/radiative heat transfer for the present case were in good agreement with the experimental data. It was found that the heat transfer augmentation coefficient attained a maximum value of 1.45 for 32 fins and for a dimensionless fin height of 0.65.

1987-08-01

360

FY 1998 annual report on the survey on development, introduction and promotion of urban type multipurpose geothermal utilization techniques; 1998 nendo toshigata tamokuteki chinetsu riyo gijutsu no kaihatsu, donyu, sokushin ni kansuru chosa hokokusho  

Energy Technology Data Exchange (ETDEWEB)

Introduction of geothermal heat pump systems, which depend on temperature differential, is investigated for urban areas, which have large energy demands. Results of the surveys on the current situations of geothermal heat pump (GHP) systems indicate that they have already numbered 300,000 units in USA and totaled more than 50,000 units in Switzerland and Northern European countries, and that they are increasing at an annual rate of higher than 10%. The results also indicate that introduction of these systems are well feasible in Japan, which generally has better topographical conditions than American and European countries, and the GHP system with vertical ground heat exchanger is investigated for its topographical and environmental considerations. These systems could annually abate approximately 52 million tons of CO2 (4.3% decrease), if disseminated to all households. They are also expected to help ...

1999-03-01

361

Three Dimensional Visualization for the Steam Injection into Water Pool using Electrical Resistance Tomography  

International Nuclear Information System (INIS)

The direct injection of steam into a water pool is a method of heat transfer used in many process industries. The amount of research in this area however is limited to the nuclear industry, with applications relating to reactor cooling systems. Electrical resistance tomography (ERT), a low cost, non-invasive and which has high temporal resolution characteristics, can be used as a visualization tool for the resistivity distribution for the steam injection into water pool such as IRWST. In this paper, three dimensional resistivity distribution of the process is obtained through ERT using iterative Gauss-Newton method. Numerical experiments are performed by assuming different resistive objects in the water pool. Numerical results show that ERT is successful in estimating the resistivity distribution for the injection of steam in the water pool

2010-10-01

362

TRACE code modeling of the horizontal steam generator of the PACTEL facility and calculation of a loss-of-feedwater experiment  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the modeling of horizontal steam generator with the TRACE code and calculation results of a loss-of-feedwater (LOF-10) experiment at the PACTEL facility. Parallel Channel Test Loop (PACTEL) is an integral test facility for a VVER-440 type nuclear reactor. The main objectives were to prepare a simulation model for its horizontal steam generator with the TRACE thermal hydraulic code and assess different modeling options of the code. PACTEL experiment LOF-10 was chosen for this assessment. The calculation results showed that TRACE is capable in simulating horizontal steam generator behavior both in steady state and during loss-of-feedwater transient. The phenomenon of heat transfer from primary to secondary side, steam superheating and flow reversal in the lowest heat exchange tubes were studied in detail. Different nodalization options were introduced. In the simulation of PACTEL loss-of-feedwater ...

2010-11-15

363

TRACE code modeling of the horizontal steam generator of the PACTEL facility and calculation of a loss-of-feedwater experiment  

International Nuclear Information System (INIS)

This paper describes the modeling of horizontal steam generator with the TRACE code and calculation results of a loss-of-feedwater (LOF-10) experiment at the PACTEL facility. Parallel Channel Test Loop (PACTEL) is an integral test facility for a VVER-440 type nuclear reactor. The main objectives were to prepare a simulation model for its horizontal steam generator with the TRACE thermal hydraulic code and assess different modeling options of the code. PACTEL experiment LOF-10 was chosen for this assessment. The calculation results showed that TRACE is capable in simulating horizontal steam generator behavior both in steady state and during loss-of-feedwater transient. The phenomenon of heat transfer from primary to secondary side, steam superheating and flow reversal in the lowest heat exchange tubes were studied in detail. Different nodalization options were introduced. In the simulation of PACTEL loss-of-feedwater ...

2010-11-01

364

The cascade of reservoirs of the ``Mayak`` Plant: Case history and the first version of a computer simulator  

Energy Technology Data Exchange (ETDEWEB)

The improvement of the ecological conditions at waste storing reservoirs is an important task of the restoration activity at Production Association (PA) ``Mayak`` (South Urals). The radionuclides mostly {sup 90}Sr, {sup 137}Cs, and chemical pollutants deposited in the reservoir water and in the bottom sediment are very dangerous sources for the contamination of Techa River below the reservoirs and the contamination of groundwater in the surrounding formations. The spreading of radioactive contaminants has both hydrogeological and the chemical features. The thermodynamic approach used to account for physical-chemical interactions between water and the bed rocks based on Gibbs free energy minimization of multicomponent system (H-O-Ca-Mg-K-Na-S-Cl-C-Sr) permitted the authors to calculate the corresponding ionic and complex species existing in the solutions, and to characterize the processes of precipitation and dissolution. The model takes into ...

1994-07-01

365

Solar desalination using humidification-dehumidification processes. Part II. An experimental investigation  

Energy Technology Data Exchange (ETDEWEB)

An experimental investigation of a humidification-dehumidification desalination (HDD) process using solar energy at the weather conditions of Suez City, Egypt, is presented. A test rig is designed and constructed to conduct this investigation under different environmental and operating conditions. The test rig consists of a solar water heater (concentrator solar collector type), solar air heater (flat plate solar collector type), humidifier tower and dehumidifier exchanger. Different variables are examined including the feed water flow rate, the air flow rate, the cooling water flow rate in the dehumidifier and the weather conditions. Comparisons between the experimental results and other published results are presented. It is found that the results of the developed mathematical model by the same authors are in good agreement with the experimental results. The tested results show that the productivity ...

2004-05-01

366

Solar desalination using humidification-dehumidification processes. Part II. An experimental investigation  

International Nuclear Information System (INIS)

An experimental investigation of a humidification-dehumidification desalination (HDD) process using solar energy at the weather conditions of Suez City, Egypt, is presented. A test rig is designed and constructed to conduct this investigation under different environmental and operating conditions. The test rig consists of a solar water heater (concentrator solar collector type), solar air heater (flat plate solar collector type), humidifier tower and dehumidifier exchanger. Different variables are examined including the feed water flow rate, the air flow rate, the cooling water flow rate in the dehumidifier and the weather conditions. Comparisons between the experimental results and other published results are presented. It is found that the results of the developed mathematical model by the same authors are in good agreement with the experimental results. The tested results show that the productivity ...

2004-05-01

367

Solar desalination using humidification dehumidification processes. Pt. 2. An experimental investigation  

Energy Technology Data Exchange (ETDEWEB)

An experimental investigation of a humidification-dehumidification desalination (HDD) process using solar energy at the weather conditions of Suez City, Egypt, is presented. A test rig is designed and constructed to conduct this investigation under different environmental and operating conditions. The test rig consists of a solar water heater (concentrator solar collector type), solar air heater (flat plate solar collector type), humidifier tower and dehumidifier exchanger. Different variables are examined including the feed water flow rate, the air flow rate, the cooling water flow rate in the dehumidifier and the weather conditions. Comparisons between the experimental results and other published results are presented. It is found that the results of the developed mathematical model by the same authors are in good agreement with the experimental results. The tested results show that the productivity ...

2004-05-01

368

Effect of vasopressin on ependymal and capillary permeability to tritiated water in cat  

Energy Technology Data Exchange (ETDEWEB)

Ependymal cells line the cerebral ventricles forming the interface that separates the cerebrospinal (CSF) and interstitial fluids (ISF). Extracellular molecules move between ependymal cells, whereas lipid soluble molecules pass both between and through cells. We measured the transfer of tritiated water (TOH) from CSF to blood across the ependymal and capillary interfaces by ventriculocisternal (VC) steady-state tissue clearance. Adult cats anesthetized with pentobarbital sodium underwent VC perfusion with the extracellular marker (/sup 14/C)sucrose and TOH added to the artificial CSF. Brain tissue was analyzed for depth of penetration of the isotopes into periventricular gray matter. We found that TOH distribution space was lower than expected from water content measurements, whereas sucrose space was normal. Using VC steady-state equations we calculated an ependymal permeability that was similar to the permeability of the cerebral capillary. ...

1986-09-01

369

Feasibility study for use of the natural convection shutdown heat removal test facility (NSTF) for VHTR water-cooled RCCS shutdown  

International Nuclear Information System (INIS)

In summary, a scaling analysis of a water-cooled Reactor Cavity Cooling System (RCCS) system was performed based on generic information on the RCCS design of PBMR. The analysis demonstrates that the water-cooled RCCS can be simulated at the ANL NSTF facility at a prototypic scale in the lateral direction and about half scale in the vertical direction. Because, by necessity, the scaling is based on a number of approximations, and because no analytical information is available on the performance of a reference water-cooled RCCS, the scaling analysis presented here needs to be 'validated' by analysis of the steady state and transient performance of a reference water-cooled RCCS design. The analysis of the RCCS performance by CFD and system codes presents a number of challenges including: strong 3-D effects in the cavity and the RCCS tubes; simulation of turbulence in flows characterized by natural ...

370

Anaerobic fermenter-decanter for the purification of residual water from sugar refineries, with recovery of combustible methane  

Energy Technology Data Exchange (ETDEWEB)

An anaerobic fermenter-decanter for the purification of residual water from the sugar industry, with recovery of methane, consists of a tank with inclined walls, with a central agitator on a vertical shaft. A flexible cover anchored by its periphery to the walls of the tank and totally submerged forms a collecting pocket for the fermentation gases. The water to be purified is introduced, after being heated to about 35, towards the bottom of the tank near the agitator. A metal collecting bell with submerged edges and with the shaft of the agitator passing axially through it is connected by its edges to a central opening of the cover. The purification yields may exceed 90%.

1981-10-06

371

Global changes and the air-sea exchange of chemicals  

International Nuclear Information System (INIS)

Present and potential future changes to the global environment have important implications for marine pollution and for the air-sea exchange of both anthropogenic and natural substances. This report addresses three issues related to the potential impact of global change on the air-sea exchange of chemicals: Global change and the air-sea transfer of the nutrients nitrogen and iron. Global change and the air-sea exchange of gases. Oceanic responses to radiative and oxidative changes in the atmosphere. The deposition of atmospheric anthropogenic nitrogen has probably increased biological productivity in coastal regions along many continental margins. Atmospheric deposition of new nitrogen may also have increased productivity somewhat in mid-ocean regions. The projected future increases of nitrogen oxide emissions from Asia, Africa and South America will provide significant increases in the rate of deposition of oxidized ...

1996-08-01

372

Gadolinium removal from the moderator system of TAPP - 3 using the three layer bed  

International Nuclear Information System (INIS)

Nitric acid leaching from the weak base anion (WBA) exchanger had been evaluated and based on this a 5% mixture of nitric acid loaded weak base anion exchanger with fresh weak base anion exchanger (NLWBA) at the bottom of the ion exchange column has been devised to maintain an outlet pH in the range of 5.0 to 5.5 during Gd removal from the moderator system of TAPP - 3 and 4. A three layered bed had been constituted wherein strong acid cation (SAC) exchanger is placed as the top layer while a mixed bed of SAC and WBA or pure WBA is used as the middle layer and the 5% NLWBA was used as the bottom most layer. This bed configuration would result in an iso-pH regime in the moderator system during the Gd removal along with quantitative removal of Gd. Two three-layer bed columns were prepared at TAPS - 3 and 4 in July 07. The resin was loaded in batches and after preparing the column, the ...

2008-12-01

373

Experimental evaluation of a non-azeotropic working fluid for geothermal heat pump system  

Energy Technology Data Exchange (ETDEWEB)

Geothermal energy resources are found in many countries. A reasonable and efficient utilization of these resources has been a worldwide concern. The application of geothermal heat pump systems (GHPS) can help increase the efficiency of using geothermal energy and reduce the thermal pollution to the earth surface. However, this is only possible with a proper working fluid. In this paper, a non-azeotropic working fluid (R290/R600a/R123) is presented for a GHPS where geothermal water at 40-45{sup o}C and heating network water at 70-80{sup o}C serve as the low and high temperature heat sources. Experimental results show that the coefficient of performance (COP) of a GHPS using the working fluid is above 3.5 with the condensation temperature above 80{sup o}C and the condensation pressure below 18 bar, while the temperature of the geothermal water is reduced from ...

2004-06-01

374

Experimental evaluation of a non-azeotropic working fluid for geothermal heat pump system  

International Nuclear Information System (INIS)

Geothermal energy resources are found in many countries. A reasonable and efficient utilization of these resources has been a worldwide concern. The application of geothermal heat pump systems (GHPS) can help increase the efficiency of using geothermal energy and reduce the thermal pollution to the earth surface. However, this is only possible with a proper working fluid. In this paper, a non-azeotropic working fluid (R290/R600a/R123) is presented for a GHPS where geothermal water at 40-45 deg. C and heating network water at 70-80 deg. C serve as the low and high temperature heat sources. Experimental results show that the coefficient of performance (COP) of a GHPS using the working fluid is above 3.5 with the condensation temperature above 80 deg. C and the condensation pressure below 18 bar, while the temperature of the geothermal water is reduced from 40-46 ...

2004-06-01

375

Conjugate heat transfer of a finned tube. Part B: Heat transfer augmentation and avoidance of heat transfer reversal by longitudinal vortex generators  

Energy Technology Data Exchange (ETDEWEB)

Numerical investigations of three-dimensional flow and heat transfer in a finned tube with punched longitudinal vortex generators (LVG`s) are carried out for Reynolds number of 250 and 300. Air with a Prandtl number of 0.7 is used as the fluid. The flow is both thermally and hydrodynamically developing. The LVG is a delta winglet pair (DWP) punched out of the fin and is located directly behind the tube, symmetrically separated by one tube diameter. The DWP generates longitudinal vortices in the wake of the tube, defers flow separation on the tube, deflects the main stream into the tube wake, and strong reduces the ``dead water zone.`` Heat transfer reversal is avoided by the DWP. Comparison of the span-averaged Nusselt numbers for the fin with and without DWP shows significant local heat transfer enhancement of several hundred percent in the tube wake. For Re = 300 and Fi = 200 the global ...

1995-08-01

376

Larger geothermal heat pump plants in the central region of Germany  

Energy Technology Data Exchange (ETDEWEB)

In recent years, several larger geothermal heat pump plants for offices or commercial areas have been designed and built in the central region of Germany, mainly in the Rhein-Main area. Systems with borehole heat exchangers (BHE; in the USA the term Vertical Loop is commonly used) as well as with shallow geothermal doublets (groundwater wells) are operational. New solutions had to be found to adapt the technology to certain site constraints, and innovative components such as thermally-enhanced grouting material have been used. This paper reviews the early development of Ground Source Heat Pumps (GSHP) for commercial buildings, gives details on a number of recent plants and discusses problems that arose during their realisation: UEG Wetzlar, a building with chemical laboratories and one of the first examples of direct cooling from BHE; DFS Langen (German Air Traffic Control Headquarters), with 154 BHE ...

2003-12-01

377

Boiling heat transfer in compact heat exchangers  

Energy Technology Data Exchange (ETDEWEB)

Small circular and noncircular channels are representative of flow passages in compact evaporators and condensers. This paper describes results of an experimental study on heat transfer to the flow boiling of refrigerant- 12 in a small circular tube of diameter = 2.46 mm. The objective of the study was to assess the effect of channel size on the heat transfer coefficient and to obtain additional insights relative to the heat transfer mechanisms. The flow channel was made of brass and had an overall length of 0.9 m. The channel wall was electrically heated, and temperatures were measured on the channel wall and in the bulk fluid stream. Voltage taps were located at the same axial locations as the stream thermocouples to allow testing over an exit quality range of 0.21 to 0.94 and a large range of mass flux (63 to 832 kg/m{sup 2}s) and heat flux (2.5 to 59 kW/m{sup 2}). Saturation ...

1994-12-31

378

Processing technology for heat resisting resin suitable for small and high performance products. ; Semiaromatic polyamide applicable to regular injection molding. Kogata-koseinoka wo jitsugensuru tainetsu jushi no kako gijutsu. ; Tsujo no shashutsu seikei ga dekiru han hokozoku poriamido  

Energy Technology Data Exchange (ETDEWEB)

Products having balanced melting point and decomposition temperature have been developed by employing nylon 6T fundamental molecular structure and selected copolymer components, Arlen being one of the products. It has heat resistance as good as that of super-engineering plastics, low water absorption, and excellent cost-performance which can be used for normal injection molding machines. The unit price per kilogram is low when its high heat resistance is taken into consideration. The coefficient of water absorption is as low as about 1/3 of that of nylon 66, and it can be considered to be a low water absorbing amide. The molding temperature is from 320[degree]C to 350[degree]C, the decomposition temperature is 395[degree]C at 2% weight decreasing temperature, and normal injection molding can be employed. It has excellent soldering resistance, high temperature rigidity, dimensional ...

1994-05-01

379

Potential for hot-dry-rock geothermal resources: experimental results  

Science.gov (United States)

Hot dry rock (HDR) contains insufficient permeability and fluid for natural hydrothermal development, but water pumped in a circulation loop through a HDR reservoir (hydraulically fractured between two drill holes) is being tested and evaluated. The formation of such in situ heat transfer systems, and subsequent testing of the man-made geothermal reservoirs in the Jemez volcanic field, New Mexico have already indicated the technical feasibility of the hot dry rock (HDR) geothermal concept. Documented production history and heat-extraction data obtained during the period from 1978 to 1980 have confirmed heat transfer, low water loss, and predictable thermal drawdown models for the HDR systems. During a nine month test of closed-loop heat extraction operations, 15 x 10/sup 6/ kWh of thermal energy were produced. The effective heat-transfer ...

1982-01-01

380

Reflux boiling heat removal in a scaled TMI-2 system test facility  

International Nuclear Information System (INIS)

An investigation of decay heat removal by the reflux boiling process was performed on a 1/18 linear-scaled test facility simulating the Three Mile Island (TMI-2) primary system. The objective was to clarify reflux boiling phenomena and core cooling effectiveness. Principal test variables included: core power, primary system water and gas inventories, and steam generator secondary-side coolant flow rate. Of 49 tests conducted, 43 achieved a steady-state heat rejection mode within 3 hours. Subsequent analyses identified two distinct reflux boiling modes. Based upon our current understanding, reflux boiling appears to be an effective process for removing decay heat in a broad range of the conditions investigated for a plant of the TMI configuration.

1980-06-01

381

Process design of the LASL Bismuth Sulfate thermochemical hydrogen cycle  

Science.gov (United States)

A new process engineering flowsheet reflecting an improved design of the LASL Bismuth Sulfate thermochemical cycle is presented. The design is based on laboratory data that indicate a lowered endothermic heat load for a partial decomposition of the solid bismuth sulfate. A small electrical energy demand should result from operation of the sulfur dioxide electrolytic step at lower acid concentration, in principle. The results of the flowsheeting analysis yield a thermal efficiency of 50% for the cycle when coupled to a conceptual fusion energy heat source at 1500/sup 0/K. A parametric analysis shows a slight drop in efficiency as the temperature of the heat source is decreased. The LASL Bismuth Sulfate thermochemical cycle appears to have potential as a means of producing hydrogen from high-temperature heat sources such as fusion, fission, and solar energy; it also appears to be competitive with ...

1979-01-01

382

Natural circulation decay heat removal experiments and analysis in an LMFBR fuel assembly  

International Nuclear Information System (INIS)

Water flow experiments were conducted on natural circulation decay heat removal with an electrically heated 91-rod bundle. Experimental results were compared with analytical predictions to provide thermal hydraulic characteristics for LMFBR Fuel assemblies under a low flow, typical of the natural circulation regime. The results revealed that, at low flow rate region (Re<1,200), axial friction loss in a heated bundle increases with buoyancy effect. The radial temperature profile provides some insight regarding the concept that coolant redistribution would occur. COBRA-V-I predictions are successfully proved validity in comparison with experimental results.

1982-07-01

383

Industrial energy thrift scheme. Energy use in the footwear, leather and fur industries. Report No. 22  

Energy Technology Data Exchange (ETDEWEB)

Visits were made to selected manufacturing units with 25 or more employees. Information was gathered on energy consumption and advice was given on the opportunities available for improving the efficiency of energy use. Potential energy savings are estimated and recommendations are made on the action that should be taken to improve the efficiency of energy use. In the footwear industry space heating controls, improvements in boiler plant and steam services along with building insulation provide most of the savings potential. In the leather industries major energy saving opportunities can be found in low-temperature drying, and heat recovery, where the use of heat pumps could contribute substantial savings in drying and process water heating. Boiler controls and good housekeeping are areas where firms can make worthwhile savings at very little capital cost. (MCW)

1980-11-01

384

Heat and mass transfer analogy studies of binary liquid mixture in comparison with ethanol-n-heptane evaporating to air  

Energy Technology Data Exchange (ETDEWEB)

An experimental and theoretical study of heat and mass transfer analogy and a comparison of that to a binary liquid mixture evaporation is presented. Common organic solvents, ethanol and n-heptane, were used to form an alcohol - hydrocarbon mixture. Studies were carried out in a horizontal rectangular channel having air flow velocities of 0.2 - 0.9 m/s. Heat transfer coefficients were measured with a copper plate resistor and mass transfer coefficients with a square pool. The heat and mass transfer analogy is presented for a system having two evaporating compounds with a fixed value of air flow and verified by measuring and comparing mass transfer coefficients for distilled water with air flow velocities of 0.2 - 0.9 m/s. An illustrative example of the use of the theory for industrial ventilation is presented. (author)

1995-12-31

385

Coupling of geothermal heat pumps with thermal solar collectors  

Energy Technology Data Exchange (ETDEWEB)

The study discussed relates to the design and development of a process consisting of combining a reversible geothermal heat pump with thermal solar collectors for building heating and cooling and the production of domestic hot water. The proposed process, called GEOSOL, has been installed in a 180 m{sup 2} private residence in 2004. This installation is the subject of long-term experimental follow-up to analyse the energy-related behavior of the installation at all times of the year. In addition, different configurations of this combined system (geothermal heat pump and thermal solar collectors) have been defined and will be simulated numerically using TRNSYS software. A comparative analysis of these different alternative versions will be conducted to determine the best configuration(s) of the GEOSOL process in terms of energy, economical and environmental performances. (author)

2007-07-15

386

Continuous method development and numerical study of HHV water gas production by pulverized coal  

British Library Electronic Table of Contents (United Kingdom)

In energy industries, it is always of difficulty to produce high heat value(HHV) gas continuously using pulverized coal. In this paper, a new type furnace for partitioned alternative gasification using pulverized coal is developed, in which the oxidation and reduction reaction occur alternatively with the dropping of pulverized coal and finally HHV gas could be continuously obtained at the reduction zone exit and low heat value(LHV) gas at the oxidation zone exit. Furthermore, the gasification characteristics and their factors in furnace are numerically simulated under two dimensional model with a self-coded program, based on heat, mass and energy transfer as well as reaction principles. It is found that the producing rate of HHV gas is 1.10Nm3/kg with heat value of 11.72MJ/Nm3, however, t...

2011-01-01

387

Augmentation of laminar flow and heat transfer in flat tubes by means of helical screw-tape inserts  

British Library Electronic Table of Contents (United Kingdom)

The heat transfer a characteristics and friction factor in the horizontal double pipes of flat tubes with full length helical screw element of different twist ratio and helical screw inserts with different spacer length are investigated. Cold and hot water are used as working fluid in tube side and shell side respectively. The experiments covered a range of Reynolds numbers 5.7x102Re1.31x103. The effect of spacer length on the heat transfer augmentation and friction factor and the effect of twist ratio on heat transfer augmentation and friction factor have been presented separately. The study shows that, the Nusslet number (Nu) and friction factor (f) decrease with the increase of S or Y for flat tube. The comparison between the data of present plain circular with that of previous plain ci...

2011-01-01

388

UK's Sizewell inquiry; funny how time slips away  

Energy Technology Data Exchange (ETDEWEB)

Comments are made on the Public Inquiry into CEGB's proposal to construct a pressurized water reactor (PWR) at Sizewell, UK. Aspects discussed include: time elapsed and its possible effect on the result; economics of nuclear power plants compared with coal-fired power plants; changes in real sterling/dollar exchange rates; effect of mineworkers' strike; the UK electric power generating system; AGR reactors compared with PWR reactors; extension of Magnox reactor life; radioactive waste management; political decisions.

1985-03-01

389

Testing of CoTreat Inorganic Ion Exchange Media for the Removal of 60Co from Thorp Pond Water  

Energy Technology Data Exchange (ETDEWEB)

CoTreat, a new inorganic ion exchange media, has been studied in the laboratory to support its application as a pre- coat to existing Funda filters in THORP feed pond plant (Sellafield, UK). This is a novel way of application of CoTreat, which is usually utilized in fixed-bed ion exchange columns in a granular form. The results present the effect of operating conditions (CoTreat dose, pond water chemistry) on CoTreat performance for the removal of Co-57 tracer from simulated pond water. Major findings include the strong dependence of Co-57 decontamination factor (DF) on feed activity. At the 200 Bq/L feed level, the observed DF was 10-20 but rose to 1000 and above when the feed level was increased to 20000 Bq/L. Calcium present in the feed was found to decrease the DF at concentrations higher than 1 ppm. The laboratory studies showed significantly higher DF's than what has been observed in ...

2003-02-25

390

Photosynthetic consequences of phenotypic plasticity in response to submergence: Rumex palustris as a case study  

British Library Electronic Table of Contents (United Kingdom)

Survival and growth of terrestrial plants is negatively affected by complete submergence. This is mainly the result of hampered gas exchange between plants and their environment, since gas diffusion is severely reduced in water compared with air, resulting in O2 deficits which limit aerobic respiration. The continuation of photosynthesis could probably alleviate submergence-stress in terrestrial plants, but its potential under water will be limited as the availability of CO2 is hampered. Several submerged terrestrial plant species, however, express plastic responses of the shoot which may reduce gas diffusion resistance and enhance benefits from underwater photosynthesis. In particular, the plasticity of the flooding-tolerant terrestrial species Rumex palustris turned out to be remarkable,...

2006-01-01

391

Heat transfer augmentation for high heat flux removal in rib-roughened narrow channels  

International Nuclear Information System (INIS)

Heat transfer augmentation in narrow rectangular channels in a target system is a very important method to remove high heat flux up to 12 MW/m"2 generated at target plates of a high-intensity proton accelerator of 1.5 GeV and 1 mA with a proton beam power of 1.5 MW. In this report, heat transfer coefficients and friction factors in narrow rectangular channels with one-sided rib-roughened surface were evaluated for fully developed flows in the range of the Reynolds number from 6,000 to 1,00,000; the rib pitch-to-height ratios (p/k) were 10,20 and 30; the rib height-to-equivalent diameter ratios (k/De) were 0.025, 0.03 and 0.1 by means of previous existing experimental correlations. The rib-roughened surface augmented heat transfer coefficients approximately 4 times higher than the smooth surface at Re=10,000, p/k=10 and k/De=0.1; friction factors increase around 22 times higher. In this case, higher ...

2001-04-08

392

Heat transfer augmentation for high heat flux removal in rib-roughened narrow channels  

Energy Technology Data Exchange (ETDEWEB)

Heat transfer augmentation in narrow rectangular channels in a target system is a very important method to remove high heat flux up to 12 MW/m{sup 2} generated at target plates of a high-intensity proton accelerator of 1.5 GeV and 1 mA with a proton beam power of 1.5 MW. In this report, heat transfer coefficients and friction factors in narrow rectangular channels with one-sided rib-roughened surface were evaluated for fully developed flows in the range of the Reynolds number from 6,000 to 1,00,000; the rib pitch-to-height ratios (p/k) were 10,20 and 30; the rib height-to-equivalent diameter ratios (k/De) were 0.025, 0.03 and 0.1 by means of previous existing experimental correlations. The rib-roughened surface augmented heat transfer coefficients approximately 4 times higher than the smooth surface at Re=10,000, p/k=10 and k/De=0.1; friction factors increase around 22 times higher. In this case, higher ...

1997-03-01

393

Prediction of thermal conductivity of ethylene glycol-water solutions by using artificial neural networks  

Energy Technology Data Exchange (ETDEWEB)

The objective of this study is to develop an artificial neural network (ANN) model to predict the thermal conductivity of ethylene glycol-water solutions based on experimentally measured variables. The thermal conductivity of solutions at different concentrations and various temperatures was measured using the cylindrical cell method that physical properties of the solution are being determined fills the annular space between two concentric cylinders. During the experiment, heat flows in the radial direction outwards through the test liquid filled in the annual gap to cooling water. In the steady state, conduction inside the cell was described by the Fourier equation in cylindrical coordinates, with boundary conditions corresponding to heat transfer between the solution and cooling water. The performance of ANN was evaluated by a regression analysis between the predicted and the ...

2009-10-15

394

Non-standard natural circulation in primary circuit of VVR-440, behavior of horizontal steam generator in this regime  

Energy Technology Data Exchange (ETDEWEB)

Analyzing various SBLOCA with high pressure safety injection (HPSI) at VVER-440/213, we met a surprising phenomenon - a 'natural' circulation post SG heat transfer reversal. This is not usual, because normal natural circulation (NC) in primary circuit is connected with positive heat transfer at SG. If there is reverse heat transfer at SG (as soon as the break enthalpy outflow is sufficient for removal of reactor decay heat), it should obstruct any natural circulation. The question was, what is the driving force of this 'non-standard natural circulation'. After all we revealed that force - it is the density difference between the colder water in reactor downcomer (cold water from HPSI) and warmer water in inner reactor (lower plenum, core, upper plenum). This phenomenon could be confusing for operating ...

2001-07-01

395

Non-standard natural circulation in primary circuit of VVR-440, behavior of horizontal steam generator in this regime  

International Nuclear Information System (INIS)

Analyzing various SBLOCA with high pressure safety injection (HPSI) at VVER-440/213, we met a surprising phenomenon - a 'natural' circulation post SG heat transfer reversal. This is not usual, because normal natural circulation (NC) in primary circuit is connected with positive heat transfer at SG. If there is reverse heat transfer at SG (as soon as the break enthalpy outflow is sufficient for removal of reactor decay heat), it should obstruct any natural circulation. The question was, what is the driving force of this 'non-standard natural circulation'. After all we revealed that force - it is the density difference between the colder water in reactor downcomer (cold water from HPSI) and warmer water in inner reactor (lower plenum, core, upper plenum). This phenomenon could be confusing for operating personal, because there would be an ...

2001-03-20

396

Particle simulation of edge pedestal formation and plasma rotation dynamics  

International Nuclear Information System (INIS)

Gyrokinetic particle simulation of edge pedestal formation and plasma rotation dynamics will be presented, and compared with experimental observations. Realistic tokamak edge geometry is used which include separatrix/X-point and material wall from EFIT g-eqdsk data. In order to handle adequately the spatially inhomogeneous electric potential in the scrape-off region, the full-f electron technique is used, in addition to the full-f ions. Monte Carlo neutral particles with wall recycling coefficient will be included self-consistently with the plasma kinetics. Ion-ion Coulomb collisions will be particle, momentum and energy conserving. Energy source for the pedestal and scrape-off plasmas is the heat flow from the core plasma, and the particle source is the ionization of the neutral atoms which are either wall recycled and/or gas puffed. The simulation will be self-consistent with the first principles nonlinear neoclassical and (electrostatic so far) turbulence ...

2007-03-26

397

Tests with cleaned and uncleaned gas on a pilot plant. Final report  

Energy Technology Data Exchange (ETDEWEB)

The possibilities for heat recovery in a cast iron melting furnace were studied. A cupola furnace which produces 40 tonnes steel per hour, produces 25,000 Nm/sup 3//h of flue gases which contain 16-22% CO. Taking into account the heat losses at the chimney where fumes are cooled to 200/sup 0/C the recoverable heat is about 12.4-10/sup 6/ kcal/h which mainly consists of combustion heat in CO. This study showed that the heat can be used for the production of electricity, which will be used in the plant. Recovery of 87 kWh of electricity per tonne of steel produced is possible. A steam turbine driven generator of 3.5 MW will be required. The combustion of the low calorific gas (approximately 400 kcal/Nm/sup 3/) has been studied and gave positive results: wet CO gas can be burnt without addition of methane and preheating of air is not required. The pilot plant consisting of a thermic ...

1986-01-01

398

Two Dimensional CFD Analyses on the Heat Transfer for a Supercritical Pressure CO_2  

International Nuclear Information System (INIS)

The Supercritical Water Cooled Reactor(SCWR) operates in a pressure around 25MPa and temperature of 293#approx#510 .deg. C. In order to study the heat transfer behaviors and good comparisons between the various fluids, a heat transfer test loop(SPHINX) using CO_2 has been constructed in KAERI as a part of international research program, I-NERI. At a supercritical pressure, the heat transfer coefficient is much larger than that estimated from the Dittus-Boelter correlation for a relatively large flow rate with moderate wall heat flux conditions. This phenomenon was explained by the rapid variations of the physical properties near the wall with the temperature. On the contrary, the heat transfer becomes worse when the bulk fluid enthalpy is below the pseudo-critical enthalpy under a low flow rate with large heat flux conditions. This ...

2005-10-27

399

On the anatomy of the adsorption heat versus loading as a function of temperature and adsorbate for a graphitic surface.  

Science.gov (United States)

In this paper we review and classify the various patterns of isosteric heat versus loading for adsorption of gases on graphitised thermal carbon black at temperatures ranging from below the 3D triple point to temperatures above it, but less than the 3D critical point. We have identified the features of heat curve and highlighted the microscopic origin of these features. The patterns vary with temperature and with the relative strength of the fluid-fluid interaction and solid-fluid interaction. For simple adsorptives (by simple we meant there is no strong association between fluid particles), the heat curve is typified by fluid-fluid attraction and layering phenomena. For adsorptives showing strong association such as water, ammonia and methanol, the heat curve essentially begins below the condensation heat and then approaches it as loading is increased. This is ...

2008-05-24

400

In situ heat transfer in man-made geothermal energy reservoirs  

Energy Technology Data Exchange (ETDEWEB)

Two hot dry rock geothermal energy reservoirs were created by hydraulic fracturing of Precambrian granitic rock on the west flank of the Valles Caldera, a dormant volcanic complex, in the Jemez Mountains of northern New Mexico. Heat was extracted in a closed-loop mode of operation, injecting water into one well and extracting the heated water from a separate production well. The first reservoir was produced by fracturing the injection well at a depth of 2.75 km (9020 ft) where the indigenous rock temperature was 185/sup 0/C. The relatively rapid thermal drawdown of the water produced from the first reservoir, 100/sup 0/C in 74 days, indicated that its effective fracture radius was about 60 m (200 ft). Average thermal power extracted was 4 MW. A second, larger reservoir was created by refracturing the injection well 180 m (600 ft) deeper. Downhole measurements of the ...

1980-01-01

401

Thermogravimetric and specific heat determinations of a commercial reconcentrated sample of ulexite, between room temperature and 1,000 degree centigree; Determinaciones termogravimetricas y de calor especifico de un concentrado comercial de ulexita, entre temperature ambiente y 1.000 grados centigrados  

Energy Technology Data Exchange (ETDEWEB)

The important amount of hydration water in the ulexite (NaCaN{sub 5}O{sub 9}.8H{sub 2}O), allows using calcination methods to increase its B{sub 2}O{sub 3} content. This paper analyses the thermal decomposition reaction of a preconcentrated ulexite through weight loss measurements, which occur during the heating of samples until 1000 degree centigree, Determinations of heat content at each temperature were made using an isoperibol calorimeter. The mean specific heat was calculated from these values, and its dependence on temperature was determined. The maximum weight loss was about 32.5% and the specific heat obtained was 1,13 kJ/kg 0 C for solid samples and 1,38 kJ/kg''0 C for fluid samples. The results are useful for the design of the industrial process, in order to determine the thermal requirements for heating calcined ulexite, and to ...

2006-07-01

402

Basic models and verification study on fuel rod heat-up and fission product release analysis modules in SAMPSON for the IMPACT project  

International Nuclear Information System (INIS)

The super simulator 'SAMPSON' has been developed to show that there exist certain safety margins for light water reactors under hypothetical severe accidents and to investigate realistic measures of accident management by simulating accidents with a parallel computer. Heat-up of fuel rods and release of fission products from fuels are important factors to evaluate source terms. Models for fuel rod heat-up, hydrogen production due to cladding oxidation and cladding deformation and failure in the core region have been developed in the fuel rod heat-up analysis module. Fuel temperatures were calculated by solving the heat conduction equation. The calculated results for fuel temperature and hydrogen production were compared with CORA-13 experiment results. The comparisons showed prediction capability for the heat-up of fuel rods. The fission product release analysis ...

1999-04-19

403

An effective convectivity model for simulation of in-vessel core melt progression in a boiling water reactor  

Energy Technology Data Exchange (ETDEWEB)

The present paper is concerned with development and application of a so-called Effective Convection Model (ECM), which aims to provide a detailed, mechanistic description of heat transfer processes in a BWR lower plenum. The ECM is a Computational Fluid Dynamics (CFD)-like tool which employs a simpler and more effective approach to compute heat transfer by solving only energy conservation equation instead of solving the full set of Navier-Stokes and energy equations by a CFD code. We implement the ECM in a CFD code (Fluent), with detailed description of the ECM development, implementation and validation. A dual approach is used to validate the ECM, namely validation against experimental data and against heat transfer results obtained by CFD predictions in the same geometries and conditions. Insights gained from CFD simulations are also used to improve ECM. The ECM capability as an effective tool to simulate ...

2007-07-01

404

An effective convectivity model for simulation of in-vessel core melt progression in a boiling water reactor  

International Nuclear Information System (INIS)

The present paper is concerned with development and application of a so-called Effective Convection Model (ECM), which aims to provide a detailed, mechanistic description of heat transfer processes in a BWR lower plenum. The ECM is a Computational Fluid Dynamics (CFD)-like tool which employs a simpler and more effective approach to compute heat transfer by solving only energy conservation equation instead of solving the full set of Navier-Stokes and energy equations by a CFD code. We implement the ECM in a CFD code (Fluent), with detailed description of the ECM development, implementation and validation. A dual approach is used to validate the ECM, namely validation against experimental data and against heat transfer results obtained by CFD predictions in the same geometries and conditions. Insights gained from CFD simulations are also used to improve ECM. The ECM capability as an effective tool to simulate ...

2007-05-13

405

Model for simulation of freezing and thawing processes in building materials  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a mathematical model for simultaneous heat and moisture transfer under freezing-thawing in porous hygroscopic material. Even below O{sup o}C, unfrozen liquid water exists in the material which plays an important role in the processes. The model takes into account the existence of unfrozen liquid water. The system is treated as a three-(gas, liquid and solid) phase system of water. Moisture chemical potential is used as a moisture potential. Under freezing, moisture chemical potential is a unique function of local temperature. So, during freezing, two unknown variables to be solved are solid water content and moisture potential or temperature. A simple example of simulation for freezing processes is shown. (author)

2001-07-01

406

[Magnetic thin film research]: Progress report year 2  

Energy Technology Data Exchange (ETDEWEB)

The work in the past year has primarily involved four areas of magnetic thin films: amorphous rare earth-transition metal alloys, epitaxial CoPt{sub 3} and Ni-Pt alloy thin films, amorphous rare earth doped Si (a new class of dilute magnetic semiconductor with large negative magnetoresistance which the authors have discovered), and exchange-coupled antiferromagnetic insulators. In the amorphous alloys, they made a systematic study of the effects of local anisotropy, macroscopic (perpendicular) anisotropy, and exchange constant on the fundamental (and practical) properties of these magnetic alloys, as originally described in the grant proposal. The work on the epitaxial Co-Pt (and more recently Ni-Pt) alloys was originally undertaken as a comparison study to the amorphous alloys. Crystalline Co-Pt alloys have many striking similarities to the amorphous rare earth-transition metal alloys: perpendicular magnetic anisotropy, magneto-optic activity, ...

1996-09-01

407

Study on separation of CO2 gas by TSS (thermal swing sublimation) method. Part 2; TSS ho (Thermal Swing Sublimation: ondo swing shokaho) ni yoru tansan gas bunri no kenkyu. 2  

Energy Technology Data Exchange (ETDEWEB)

TSS (thermal swing sublimation) method was studied which uses vaporization heat and sensible heat of LNG for solidification and separation of CO2 gas in waste gases of LNG-fired combined cycle power generation system. In experiment, the mixed gas composed of CO2, H2O and N2 was used for simulating waste gas of LNG-fired combined cycle power generation systems, and the growth behavior of ice and dry ice was studied for developing dry ice making technology under low-temperature condition. As the experimental result, the following were clarified: various crystal structures depending on cooling temperature, the effect of gas flow rate on peeling of surface precipitated solids, and solidification characteristics of H2O/CO2 mixed gas. The growth rate of precipitated solid film thickness decreased with an increase in gas flow rate, while increased with CO2 concentration. The shape of a dry ice sublimator similar to that of a fluidized bed ...

1997-03-21

408

Microwave radiation effects on the thermally driven oxidase of erythrocytes  

Energy Technology Data Exchange (ETDEWEB)

Sheep red blood cells (SRBCs) were labelled with a concanavalin A-luminol-bovine serum albumin conjugate specific for the transmembrane anion transport protein (Band 3) and exposed to 2450-MHz continuous-wave microwave radiation at an average specific absorption rate of 91W/kg for 10 min. The temperature was held constant at 25, 37, 40, 42, or 45C with an airflow heat-exchange system. Following exposure to microwave or air heating, the decrease in residual base-activated chemiluminescence (CL) of the SRBCs was measured as an indication of infield oxidase activity. Air heating resulted in a significant decrease in residual CL at temperatures above 37C (74% decrease at 45C). Microwave radiation inhibited the decline in residual CL above 37C. At 45C the inhibition was 40%. The results suggest microwave radiation either reversibly altered the thermodynamics of oxygen binding to haemoglobin or failed to energize a significant ...

1986-01-01

409

Historical development of alloy 800  

International Nuclear Information System (INIS)

Alloy 800 was developed in 1949 by The International Nickel Company, Inc. The basic composition, nominally 32wt.%Ni, 20.5wt.%Cr and 46wt.%Fe, was designed to provide a stable, fully austenitic structure and to impart high strength combined with resistance to oxidation, carburization and corrosion in a wide variety of aggressive industrial environments at elevated temperatures. In the short span of twenty-five years, alloy 800 has earned a unique position in the family of heat- and corrosion-resistant materials. Established uses include a wide range of applications in the industrial heating field, in the petro-chemical industry, in domestic appliances and in food processing equipment. The good performance of alloy 800 in these applications has led to its use as boiler tube material both in fossil-fired plants and in HTGR and PWR nuclear power systems. Recently, it was specified for a PHW CANDU reactor and it is now being considered as ...

410

Crystallization fouling of calcium sulfate dihydrate on heat-transfer surfaces  

Energy Technology Data Exchange (ETDEWEB)

The present paper deals with the fouling process of calcium sulfate dehydrate on heat-transfer surfaces. The crystallization of calcium sulfate showed typical asymptotic fouling curves, the asymptotic value of which was greatly influenced by the surface temperature and fluid velocity. The fouling mechanism was discussed with a generalized fouling model and proved to be surface process controlled, where the activation energy was 6.2 {times} 10{sup 4} J/mol. The availability of mechanical cleaning against the formed scale was quantitatively evaluated by applying the particle abrasion method. The removal test verified that the removing rate per unit particle concentration decreased in an inverse proportion to the overall particle load, to the power of 0.8, and that it was affected by the fluid velocity. The observed final residual fouling resistance decreased asymptotically with an increase in particle concentration. The suitable concentration of the abrasive ...

1996-02-01

411

Public hearings on water management in Quebec: First Nations and water resources -- Supporting documentation for the Commission Workshop at Mashteuiatsh, Aug 18, 1999; Consultation publique sur la gestion de l'eau au Quebec: Les premieres nations et la ressource eau -- Document de soutien a atelier de travail de la Commission du 18 aout 1999 a Masteuiatsh  

Energy Technology Data Exchange (ETDEWEB)

Since mid-March the Commission on Water Management, with the assistance of the appropriate ministries, visited all regions of the province in order to acquaint themselves first hand with regional water management problems. During the month of June, the Commission also organized a series of ten workshops, attended by a limited number of experts, to explore in depth certain specific questions in the area of water management. During these public sessions the Commission hoped to discuss specifically the specific questions relating to water management problems of First Nations communities, bearing in mind the essential nature of water in maintaining traditional activities. The workshop took place on the Montanard reserve of Mashteuiatsh (Pointe-Bleu). The morning session was devoted to presentations by invited experts, followed by an exchange of views between the ...

1999-08-13

412

Wax and hydrate control with electrical power  

Energy Technology Data Exchange (ETDEWEB)

Electrical heating of subsea flowlines is an effective way to prevent wax and hydrate information, especially for long transportation distances and in low-temperature deep water. Systems are available for use in conjunction with bundles, pipe-in-pipe, and wet-thermal-insulation systems. These systems provide environmentally friendly fluid-temperature control without chemicals or flaring for pipeline depressurizing. Enhanced production is achieved because no time is lost by unnecessary depressurizing, pigging, heating-medium circulation, or removal of hydrate and wax blockages. The seabed temperature at 100-m and greater water depths may range from 7 to {minus}1.5 C, causing a rapid cooling of the hot well streams being transported in subsea flowlines. Under these supercooling conditions, vulnerable crude oils and multiphase compositions will deposit wax and asphalts; also the ...

1997-08-01

413

Survey of UEC estimates for space heating, DHW heating, and appliances energy usage  

Energy Technology Data Exchange (ETDEWEB)

Natural Resources Canada commissioned an informal survey in which 18 organizations, mainly utilities from across Canada were contacted by letter or fax to gather data regarding unit energy consumption (UEC) of space heating, domestic hot water (DHW) heating and appliances. The data was used in updating and refining the residential energy end-use model used at NRCan. The survey included energy load, UEC, efficiency, and per cent saturation for both space heating and water heating equipment for all fuel types including electric, natural gas, oil, wood and propane used in single detached, single attached, apartment and mobile homes. A list of UEC and per cent saturation for major appliances such as refrigerators, freezers, clothes washers and dryers, cooktop/ovens, central air-conditioners, and lighting is also included in the survey. The collected data was ...

1998-03-01

414

Two-fluid modeling of condensation in the presence of noncondensables in two-phase channel flows  

Energy Technology Data Exchange (ETDEWEB)

Condensing two-phase channel flow occurs in many industrial applications, including heating and refrigeration systems. It can also occur in certain nuclear reactor accidents. For example, during a small-break loss-of-coolant accident in a pressurized water reactor, following the partial depletion of the primary coolant, condensation of steam on the primary side of the steam generator tubes can provide a heat sink for disposal of the decay heat generated in the reactor core. Condensing two-phase flow can also play an important role in the operation of the passive emergency cooling system in the advanced simplified boiling water reactor. Here, steady-state condensation in the presence of a noncondensable in a concurrent two-phase channel flow is analyzed using a two-fluid model. The effect of noncondensables on the combined heat transfer at the liquid-gas mixture ...

1995-01-01

415

Thermal stress cracking and the enhancement of heat extraction from fractured geothermal reservoirs  

Science.gov (United States)

Given sufficient time, the extraction of heat from geothermal reservoirs formed by the hydraulic fracturing of competent rock will eventually result in the formation of thermal stress cracks in the reservoir. These cracks penetrate the rock in a manner such that the penetration-to-spacing ratio is approximately one. The penetration depends upon the extent of cooling and the square root of time. Initially then, the cracks are closely spaced and penetrate but little, so that a crazing pattern is apparent; but with increasing time some of these cracks, now more widely spaced, grow deeper. Eventually these larger cracks attain a critical aperture such that significant rates of water flow can be established within them and thus the newly created heat transfer area becomes useful for heat extraction. At the same time that cracks are forming within the main reservoir, thermal cracking also occurs in the ...

1978-04-01

416

Potential for geothermal development in Southern Poland  

Energy Technology Data Exchange (ETDEWEB)

This paper discusses the potential for geothermal energy use in the central part of Southern Poland, such as the availability of thermal aquifers and the techniques for putting the latter to practical use. The geological and geothermal features of the region are presented within the context of the existence of aquifers containing geothermal resources that could be used in space heating. Also discussed are the three main geological units where thermal waters are known to exist: the Carpathians, the Miechow Trough, and the Silesian-Cracow Monocline. Particularly favourable hydrogeological conditions exist in the Inner Carpathians, in the Podhale Trough, where there is already one geothermal company using geothermal energy, Geotermia Podhalanska S.A. Equally interesting from the geothermal point of view are the areas north of the Cracow-Tarnow line, where, in Mesozoic aquifers, water temperatures range from 20 to 60 {sup o}C. ...

2004-06-01

417

Heavy water reactor facility large-scale containment cooling test program  

Science.gov (United States)

The Heavy Water Reactor Facility (HWRF), as part of the defense-in-depth philosophy to mitigate the effect of design-basis and severe accidents, is equipped with a passive containment cooling system (PCCS). The function of the PCCS is to provide a safety-grade path to the ultimate heat sink for the removal of the reactor coolant system sensible heat and core decay heat. Ambient air enters an annular space between the steel containment shell and the surrounding concrete shield building through inlets in the shield building wall, is heated via natural convection, rises, and exits the building through a chimney located above the containment dome. A test program is in place to access parameters important to the effective operation of the PCCS. This paper focuses on the large-scale tests (LSTs). The objectives of these tests are as follows: (1) demonstrate natural circulation cooling ...

1992-01-01

418

Heavy water reactor facility large-scale containment cooling test program  

International Nuclear Information System (INIS)

The Heavy Water Reactor Facility (HWRF), as part of the defense-in-depth philosophy to mitigate the effect of design-basis and severe accidents, is equipped with a passive containment cooling system (PCCS). The function of the PCCS is to provide a safety-grade path to the ultimate heat sink for the removal of the reactor coolant system sensible heat and core decay heat. Ambient air enters an annular space between the steel containment shell and the surrounding concrete shield building through inlets in the shield building wall, is heated via natural convection, rises, and exits the building through a chimney located above the containment dome. A test program is in place to access parameters important to the effective operation of the PCCS. This paper focuses on the large-scale tests (LSTs). The objectives of these tests are as follows: (1) demonstrate natural circulation cooling ...

1992-11-15

419

Ion-exchange scheme for selective removal of gadolinium nitrate from the moderator system of 540 MWe Indian PHWRs using macroporous strong acid cation and macro porous weak base anion resins  

International Nuclear Information System (INIS)

Gadolinium nitrate has been employed in Indian nuclear reactors for the first time as soluble neutron poison in the heavy water moderators of the 540 MWe PHWRs TAPS 3 and 4, as a fast acting secondary shut down system (SDS-2); and also for reactivity shim. For this purpose, the moderator purification system is currently equipped with special ion-exchange columns/schemes, developed by present authors. However, for gadolinium removal from moderator in the post SDS-2 scenario, the two stage ion-exchange - cation bed operation followed by mixed bed operation - results in low pH conditions persisting in the moderator for a few hours, which gives rise to certain operational problems. The present paper describes a mixed bed ion-exchange scheme employing macro-porous strong acid cation and macro-porous weak base anion resins, which has been developed to eliminate acidic conditions and gives a better pH control. ...

2008-12-01

420

DIVALENT ION EXCHANGE WITH ALKALI  

Energy Technology Data Exchange (ETDEWEB)

Exchange of hardness ions is important in enhanced oil recovery with chemical additives. In both micellar-polymer and caustic flooding processes, multivalent ions released from rock surfaces can interact with anionic surfactants, rendering them preferentially oil soluble and/or insoluble in water. Because hardness cations are sparingly soluble and precipitate in alkaline solutions, such solutions may be more efficient as surfactant flood preflushes than are softened brines. Multivalent ion precipitation may also occur in alkaline waterflooding. To permit design of such processes, this paper presents a chromatographic theory for simultaneous ion exchange with precipitation of divalent ions. Theoretical effluent histories and concentration profiles are presented for the cases of finite pulses and continuous injection of hydroxide ions into linear cores. Complete capture of the insoluble salt particles is assumed. Results are ...

1980-05-01

421

Energy and exergy analysis of a ground source (geothermal) heat pump system  

International Nuclear Information System (INIS)

Ground source heat pumps (GSHPs), often referred to as geothermal heat pumps (GHPs), offer an attractive option for heating and cooling residential and commercial buildings owing to their higher energy efficiency compared with conventional systems. GSHPs have been used for four years in the Turkish market, although they have been in use for more years in developed countries. The purpose of this study is to present an energy and exergy analysis of a GSHP system with a 50 m vertical 1.25 in. nominal diameter U-bend ground heat exchanger. This system was applied to a 65 m"2 room in the Solar Energy Institute, Ege University, Izmir, for the first time at the university level in Turkey. The Institute, built in 1986, has a livable floor area of 3000 m"2 and uses passive solar techniques. The heating and cooling loads of the room studied were 3.8 and 4.2 kW at design ...

2004-03-01

422

Development of a Commercial Process for the Production of Silicon Carbide Fibrils  

Energy Technology Data Exchange (ETDEWEB)

The current work continues a project completed in 1999 by ReMaxCo Technologies in which a novel, microwave based, VLS Silicon Carbide Fibrils concept was verified. This project continues the process development of a pilot scale commercial reactor. Success will lead to sufficient quantities of fibrils to expand work by ORNL and others on heat exchanger tube development. A semicontinuous, microwave heated, vacuum reactor was designed, fabricated and tested in these experiments. Cylindrical aluminum oxide reaction boats are coated, on the inner surface, with a catalyst and placed into the reactor under a light vacuum. A series of reaction boats are then moved, one at a time, through the reactor. Each boat is first preheated with resistance heaters to 850 C to 900 C. Each reaction boat is then moved, in turn, to the microwave heated section. The catalyst is heated to the required ...

2003-04-22

423

Comparison between experimental data and numerical modeling for the natural circulation phenomenon  

Energy Technology Data Exchange (ETDEWEB)

There is a crescent interest in the scientific community in the study of natural circulation phenomenon. New generation of compact nuclear reactors uses the natural circulation of the fluid as a system of cooling and of residual heat removal in case of accident or shutdown. The objective of this paper is to present a study through the comparison of experimental data and numerical simulation for the natural circulation phenomenon in one and two-phase flow regime. An experimental circuit built with glass tubes is used for the experiments. Thus, it allows the thermal hydraulic phenomena visualization. There is an electric heater as the heat source, a heat exchanger as the heat sink and an expansion tank to accommodate fluid density excursions. The circuit instrumentation consists of thermocouples and pressure meters to better keep track of the flow and heat ...

2009-07-01

424

Analysis and design of an ultra-high-temperature, hydrogen-fueled MHD generator as an open cycle power supply  

Energy Technology Data Exchange (ETDEWEB)

The theoretical analysis of a partially-ionized hydrogen gas flow (gas temperatures of approximately 10,000 to 20,000 K) through a particular class of magnetohydrodynamic (MHD) generators and the preliminary design of these MHD generators as open cycle, electric power supplies are performed. Analysis of the gas flow through these ultra-high temperature MHD generators requires a coupled gas dynamics/radiative heat transfer solution. Gas dynamics are modeled by a set of quasi-one-dimensional, nonlinear differential equations which account for friction, convective and radiative heat transfer and the interaction between the ionized gas and applied magnetic field. Radiative heat transfer is modeled using non-gray, absorbing-emitting two- and three-dimensional P-1 approximations which permit an arbitrary variation of the spectral absorption coefficient with frequency. Gas dynamics and radiative heat transfer ...

1990-01-01

425

Two-phase Flow Regime Maps in Horizontal and Vertical Tubes  

Energy Technology Data Exchange (ETDEWEB)

A safety analysis code to design a pressurized water reactor and to obtain the licenses including entire proprietary rights is under development in domestic R and D project. The tasks of KAERI is to develop the constitutive relations including models for defining flow regimes and flow regime related models for inter-phase friction, wall frictions, wall heat transfer, and interphase heat and mass transfer in the two-phase three-field equations. In this paper, the process will be presented for choosing the best flow regime maps which occur in gas-liquid two-phase flow in horizontal and vertical tubes.

2007-10-15

426

Two-phase Flow Regime Maps in Horizontal and Vertical Tubes  

International Nuclear Information System (INIS)

A safety analysis code to design a pressurized water reactor and to obtain the licenses including entire proprietary rights is under development in domestic R and D project. The tasks of KAERI is to develop the constitutive relations including models for defining flow regimes and flow regime related models for inter-phase friction, wall frictions, wall heat transfer, and interphase heat and mass transfer in the two-phase three-field equations. In this paper, the process will be presented for choosing the best flow regime maps which occur in gas-liquid two-phase flow in horizontal and vertical tubes.

2007-10-01

427

Overview of US LMFBR Structural Materials Mechanical Properties Program  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the objective, scope, and status of the US Department of Energy's Materials and Structures Program to develop a data base on mechanical properties of structural materials for out-of-core structures and components for LMFBRs. Information on the development of a reference data base on materials for the reactor system, reactor enclosure system, primary heat transport system, intermediate heat transport system, and steam generator system is included. In addition, the development of the data and analyses to account for the effects of temperature and stress, as well as water/steam, sodium, and radiation environments, is described. Plans for the development of alternative materials for future out-of-core applications are presented.

1983-01-01

428

Overview of U.S. LMFBR structural materials mechanical properties program  

International Nuclear Information System (INIS)

This paper presents the objective, scope, and status of the U.S. Department of Energy's Materials and Structures Program to develop a data base on mechanical properties of structural materials for out-of-core structures and components for LMFBRs. Information on the development of a reference data base on materials for the reactor system, reactor enclosure system, primary heat transport system, intermediate heat transport system, and steam generator system is included. In addition, the development of the data and analyses to account for the effects of temperature and stress, as well as water/steam, sodium, and radiation environments, is described. Plans for the development of alternative materials for future out-of-core applications are presented. (author).

1983-10-10

429

Improvement of FLOWER code and its application in Daya Bay  

International Nuclear Information System (INIS)

FLOWER, a computer code recommended by USNRC for assessing the environmental impact in tidal regions, was adapted and improved so as to be suitable to deal with the influence of drift stream along seashore to the dilution of contaminants and heat in the bay mouth. And the code outputs were presented with more mid-results such as average concentrations and temperature values for all tides considered. Finally, the modified code is applied to the dispersion calculation of heat and liquid effluents from Daya Bay Nuclear Power Plant, and the impacts from routine operation of the plant on Daya Bay sea waters were given.

430

Heat recovery in polyester production: a case study  

Energy Technology Data Exchange (ETDEWEB)

Energy savings in the synthetic fiber industry could be realized by using autoclave reactor condensate and boiler flue gas heat recovery. The non-cellulose (polyester) production process analysis shows that condensate returning from the reactor to the steam boiler raises inlet temperature, giving a reduced fuel requirement of about 8%. Also, boiler flue gas with a sufficiently high outlet temperature for boiler feed water and combustion air preheating results in further fuel savings. The process with an economizer saves up to 8.44%, and with a combustion air preheater, 6.25%. (Author)

1997-07-01

431

Geothermal resource assessment of the New England states  

Energy Technology Data Exchange (ETDEWEB)

With the exception of Sand Springs in Williamstown, Massachusetts, there are no identifiable hydrothermal geothermal resources in the New England region. The radioactive plutons of the White Mountains of New Hampshire do not, apparently, contain sufficient stored heat to make them a feasible target for an induced hydrothermal system such as exists at Fenton Hill near Los Alamos, New Mexico. The only potential source of low grade heat is the large volume of ground water contained within the unconsolidated sediments related to the Pleistocene glaciation of the region. During the course of the survey an unusual and unexplained thermal anomaly was discovered in St. Johnsbury, Vermont, which is described.

1982-01-01

432

Flow Regime Map Models for the Horizontal and Vertical Pipes for the SPACE code  

Energy Technology Data Exchange (ETDEWEB)

A safety analysis code, named as SPACE, for a pressurized water reactor is under development to obtain a licensing to be used for the PWR design and to hold entire proprietary rights. The task of KAERI is to develop the physical models and correlations which are required to solve the field equations. It can be divided into four parts; i) flow regime determination, ii) wall heat transfer, iii) wall and interfacial friction, iv) interfacial heat and mass transfer. This paper will describe the process to develop the models for the two-phase flow regime maps in the horizontal and vertical pipes.

2008-05-15

433

Flow Regime Map Models for the Horizontal and Vertical Pipes for the SPACE code  

International Nuclear Information System (INIS)

A safety analysis code, named as SPACE, for a pressurized water reactor is under development to obtain a licensing to be used for the PWR design and to hold entire proprietary rights. The task of KAERI is to develop the physical models and correlations which are required to solve the field equations. It can be divided into four parts; i) flow regime determination, ii) wall heat transfer, iii) wall and interfacial friction, iv) interfacial heat and mass transfer. This paper will describe the process to develop the models for the two-phase flow regime maps in the horizontal and vertical pipes.

2008-05-01

434

Core preservation with a laminated, heat-sealed package  

Energy Technology Data Exchange (ETDEWEB)

A core preservation package was developed to maintain the reservoir characteristics of core samples and consequently to improve the quality of data obtained through laboratory core analyses. The package is a heat-sealable plastic-aluminum laminate similar to those common in the food-packaging industry. The laminated core preservation package acts as an impermeable barrier to water vapor and gases, and is resistant to chemical alteration and degradation by core fluids. These performance characteristics result in effective core preservation by maintaining the fluid content of the core. Other advantages of the laminated package are that it is fast and simple to use and eliminates the cumbersome dip-coat step used in some core preservation methods.

1988-12-01

435

A mathematical model for a thermally coupled humidification?dehumidification desalination process  

British Library Electronic Table of Contents (United Kingdom)

The humidification?dehumidification process is an interesting technique that has been adapted for water desalination. Previous works experimentally investigated desalination processes in the shell and tube columns, where the humidification and dehumidification were thermally coupled and simultaneously performed at the tube and shell sides, respectively. In this work, a comprehensive steady-state mathematical model was developed for such a humidification?dehumidification desalination process by taking into account the heat and mass balances on both sides of the desalting column, the mass transfer rate at the humidification side, and the heat transfer rate between the dehumidification side and humidification side. Meanwhile, the mass transfer coefficient at the humidification side and the to...

2006-01-01

436

Study on tritium activity build-up in moderator and primary heat transport systems in 540 MWe reactor  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by Deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on Tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-3 and 4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)

2006-11-13

437

Study on tritium activity build-up in moderator and primary heat transport (PHT) systems in 540 MWe reactor  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)

2005-11-23

438

Recriticality of a BWR core during reflood after control blade meltdown  

Energy Technology Data Exchange (ETDEWEB)

In nuclear reactor safety research, the question of the possible consequences of delayed core reflood during severe accidents or anticipated transient without scram transients in boiling water reactors (BWRs) has been raised. One can envisage a very low probability accident scenario leading to core uncovery and core heat-up, followed by control blade melting and subsequential delayed reflooding of the core with unborated water before its degradation. Reflooding of the hot core causes significant increases in the peak heating, melting, and hydrogen production rates, thus increasing the probability of core degradation. However, as has been established, debris beds formed from shattered fuel rods and quenched fuel melt will be undermoderated. The reflood process of a voided, intact core was examined using the TRAC/BFI CODE.

1994-12-31

439

Development of standard solutions for the Minergie standard; Standardloesungen - Entwicklung von Standardloesungen fuer den Minergie-Standard  

Energy Technology Data Exchange (ETDEWEB)

This final report for the Swiss Federal Office of Energy (SFOE) examines a project that aimed to define standard solutions for use in buildings built to meet Minergie low energy consumption standards. These standard solutions are to provide a way of meeting Minergie standards in an easy way and thus further the use of the standard and also assure quality at the same time. The report describes how the solutions were developed on the basis of a selection of existing Minergie buildings. For various combinations of heating systems - wood, wood/solar, heat pumps (brine-water and air-water), gas/solar and oil/solar - the appropriate U-values for various building elements are listed. The resulting Minergie forms and guides are listed.

2003-07-01

440

A model of chemistry and thermal hydraulics in PWR fuel crud deposits  

Energy Technology Data Exchange (ETDEWEB)

A model is described for simulating thermal hydraulic and chemical conditions within fuel crud deposits. Heat transfer takes place by wick boiling in which water flows through the porous deposit and evaporates into steam at the surface of chimneys. The transport and chemistry of dissolved species within the deposit is also modelled. This chemistry includes the equilibrium chemistry of Li/boric acid species, the equilibrium chemistry of Fe/Ni species and the radiolysis chemistry of water. The unique feature of this model is that the chemistry is coupled to the thermal hydraulics via the increase in the saturation temperature with the concentration of dissolved species. This has a profound effect on evaporative heat transfer within thick deposits, leading to conditions that explain the precipitation of LiBO{sub 2} and the possible formation of bonaccordite. The model helps understand several crud scrape ...

2006-07-01

441

The potential of solar-driven humidification-dehumidification desalination for small-scale decentralized water production  

Energy Technology Data Exchange (ETDEWEB)

World-wide water scarcity, especially in the developing world, indicates a pressing need to develop inexpensive, decentralized small-scale desalination technologies which use renewable resources of energy. This paper provides a comprehensive review of the state-of-the-art in one of the most promising of these technologies, solar-driven humidification-dehumidification (HDH) desalination. Previous studies have investigated many different variations on the HDH cycle. In this paper, performance parameters which enable comparison of the various versions of the HDH cycle have been defined and evaluated. To better compare these cycles, each has been represented in psychometric coordinates. The principal components of the HDH system are also reviewed and compared, including the humidifier, solar heaters, and dehumidifiers. Particular attention is given to solar air heaters, for which design data is limited; and direct air heating is compared to direct ...

2010-05-15

442

Pitting corrosion of copper coiled tubes in the air conditioning system having the open heat storage water tank; Kaihokei chikunetsuso reionsuika ni okeru kuchokiyo kokan no koshoku ni tsuite  

Energy Technology Data Exchange (ETDEWEB)

In order to investigate pitting corrosion of copper coiled tubes for air conditioning systems with an open heat storage water tank, the effect of carbon films on the inner surface of copper tubes and fine corrosion-product particles in water as environmental corrosion factor on pitting corrosion was studied by field test under real environmental conditions. As a result, pitting corrosion of copper tubes was caused by synergistic effect of fine corrosion-product particles in water and carbon films. Generation of pitting corrosion was derived from deposition of the films and particles, while considerable growth of pitting corrosion was dependent on the particles. Time variation of spontaneous electrode potential also showed the effect of the film and particle. Pitting corrosion potential was estimated to be nearly 100mV vs. SCE. The following measures against pitting corrosion were considered to be ...

1998-11-15

443

3D-nuclear heat generation in PCC-charcoal filter in TAPP-3 and 4  

International Nuclear Information System (INIS)

This paper deals with the calculations of 3D nuclear heat generation profile in the charcoal filter and subsequently the commencement time of Primary Containment Cleanup (PCC) system of 540MWe Pressurized Heavy Water Reactor (PHWR). Fuel failure is predicted due to overheating of the fuel under loss of Coolant Accident (LOCA) without Emergency Core Cooling System (LOCA without ECCS). Subsequently fission product gasses along with water vapours are released to Reactor Building (RB) atmosphere. Plate-out and water trapping mechanism stabilizes the concentration of significant fission products i.e. radioiodines in about 4 hours before being circulated through charcoal filters of Containment Cleanup system. After cleaning up the RB atmosphere, it is discharged to outside atmosphere through stack. The isotopes of radioiodine emit beta and gamma radiations. Gamma radiations are partly stopped within the ...

2006-11-13

444

New approaches to the design of the combustion system for thermophotovoltaic applications  

Energy Technology Data Exchange (ETDEWEB)

A thermophotovoltaic (TPV) generator for electric vehicles has been designed and developed. In this paper we focus on the combustion system and the heat regenerator. The system has been designed to work as a range extender for electric vehicles. This solution would provide energy always available on the vehicle, which would run even if the battery level were low. Several configurations for the burner and for the heat exchanger have been investigated and a comparison of these is presented. The different solutions have been studied both theoretically and experimentally. In this paper, we report on the work carried out to build a TPV device capable of yielding 6 kW of electric power to recharge the battery pack of an electric city-car. The project has been divided into four steps: (1) pre-design of different configurations of the burner and heat exchanger using non-commercial software ...

2003-05-01

445

Spattering and Crackle of Hot Cooking Oil with Water: A Classroom Demonstration and Discussion  

Science.gov (United States)

Any student that has spent time in the kitchen knows that hot vegetable oil will pop and spatter violently after coming into contact with water such as that on the surface of foods (meat, fish, potatoes, etc.). This well-known effect can be used as an instructional resource to promote cooperative, active, and inquiry-based learning about central concepts of chemistry including boiling point, miscibility, and density of liquids. The starting point of the learning activity is a demonstration of (i) the effect of adding a drop of water to hot (as for cooking) vegetable oil and (ii) the effect of adding a drop of vegetable oil to hot water (near its boiling point). Intermolecular interactions, properties of vegetable oils, and a variety of other topics, such as the importance of other heat points (smoke, flash, and fire) for oils, the fundamental of the crackle test for checking the presence of ...

2009-11-01

446

Modeling of thermal and hydrodynamic aspects of molten jet/water interactions  

Energy Technology Data Exchange (ETDEWEB)

In order to predict the effect of a fuel-coolant interaction after a hypothetical core-melt-down accident, a phenomenological model has been developed to describe the thermal and hydrodynamic behavior of a high-temperature molten jet when it interacts with saturated or subcooled water in a film boiling regime. The mechanisms of jet-material erosion were analyzed by Kelvin-Helmholtz instabilities on the coherent column and by boundary layer stripping on the leading edge. The heat transfer coefficient, vapor-film thickness, and net steam generation, all of which strongly affect the jet-breakup behavior, were solved analytically. It was found that the jet breakup (or erosion) depends strongly on the steam generation from the jet/water interaction. The jet-breakup length (i.e., penetration distance) was found to be sensitive to the initial jet temperature, water subcooling, and the physical state of the ...

1989-01-01

447

Environmentally assisted cracking in light-water reactors: Semi-annual report, January--June 1997. Volume 24  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes work performed by Argonne National Laboratory on fatigue and environmentally assisted cracking (EAC) in light water reactors from January 1997 to June 1997. Topics that have been investigated include (a) fatigue of carbon, low-alloy, and austenitic stainless steels (SSs) used in reactor piping and pressure vessels, (b) irradiation-assisted stress corrosion cracking of Types 304 and 304L SS, and (c) EAC of Alloys 600 and 690. Fatigue tests were conducted on ferritic and austenitic SSs in water that contained various concentrations of dissolved oxygen (DO) to determine whether a slow strain rate applied during various portions of a tensile-loading cycle is equally effective in decreasing fatigue life. Slow-strain-rate-tensile tests were conducted in simulated boiling water reactor (BWR) water at 288 C on SS specimens irradiated to a low fluence in the Halden reactor and the results ...

1998-04-01

449

The solar energy in Lebanon: an inexhaustible and economical energy  

International Nuclear Information System (INIS)

The article describes the energy in Lebanon. In 1995, 97% of the imported energy was based on hydrocarbons. Fuel and gas oil present 66% of the final energy. Air pollution is mainly caused by the transportation sector (vehicles and buses...) which presents 70% of the global atmospheric pollution. Renewable energy such as biomass, fossil energy, hydro-energy, solar energy... are also described. The solar energy was defined as a best solution that preserve health in Lebanon. The different applications of the solar for energy production is discussed: photovoltaic , thermal heating, sanitary hot water, electrical heaters, solar water heaters...In conclusion, solar heaters economize 80% of the annual energy expenses

1997-06-01

450

Lightweight bricks manufactured from water treatment sludge and rice husks.  

Science.gov (United States)

Novel lightweight bricks have been produced by sintering mixes of dried water treatment sludge and rice husk. Samples containing up to 20 wt.% rice husk have been fired using a heating schedule that allowed effective organic burn-out. Rice husk addition increased the porosity of sintered samples and higher sintering temperatures increased compressive strengths. Materials containing 15 wt.% rice husk that were sintered at 1100 degrees C produced low bulk density and relatively high strength materials that were compliant with relevant Taiwan standards for use as lightweight bricks. PMID:19596512

2009-06-17

451

Hot water from the sun; Increasing awareness of energy saving considerations - thermal solar systems booming. Heisses Wasser von der Sonne; Umweltbewusster Umgang mit Energieressourcen findet immer mehr Anhaenger - Boom fuer thermische Solarsysteme  

Energy Technology Data Exchange (ETDEWEB)

Thermal solar energy plants for water heating have experienced an enormous boom during the last years. Thus, a total of 200000 square metres of collector surface was installed on German rooves in 1991. This was three times as much as in the year before. And this trend of conserving natural resources by using the energy of the sun is still undiminished. (orig.)

1993-11-01

452

Causes of denting. Volume 5. Contaminant threshold tests. Final report  

Science.gov (United States)

Steam generators in PWR plants have been subject to denting corrosion as a result of nonprotective magnetite forming on the carbon steel support plate causing the voluminous corrosion product that eventually crimps (dents) the heat transfer tube at the support plate interface. This project was designed to determine the causes of denting and the usefulness of water chemistry changes meant to arrest denting. This volume of the final report describes laboratory research on the correlation of water chemistry, superheat, and oxygen ingress with denting in steam generators.

1983-12-01

453

A horizontal steam generator for the Indian 235 MW heavy water nuclear power plants  

International Nuclear Information System (INIS)

In this paper the thermal design of a horizontal steam generator for the Indian PHWR nuclear power plant is described. The main attraction is absence of tube sheet and use of stainless steel 'U' tubes. It is emphasised that with appropriate water chemistry it is possible to use stainless steel tubes, which is many times cheaper than the Incoloy tubes used elsewhere. The design approach, applicable equation for the design and the results of computation in the form of heat transfer area and some important dimensions of the steam generator are presented.

1993-11-01

454

Effect of design improvements in heavy water management systems to reduce heavy water losses and tritium releases at Wolsong 2,3 and 4  

International Nuclear Information System (INIS)

Design improvements are being incorporated into the heavy water management systems at Wolsong 2,3 and 4 to reduce the load on the vapour recovery driers and upgraders and the heavy water losses via the stack. There will also be improvements to monitor heavy water and tritium releases. This paper describes the improvements, gives background on heavy water balance mechanism, the historical trends for heavy water recovery/losses and estimated dose to the member of the public critical group resulting from the airborne and waterborne releases. The measured tritium activity levels in the heat transport system (HTS) and moderator system at Wolsong 1 are given. Using these activity levels and heavy water loss data, tritium losses from the dried and ventilated areas are estimated. A qualitative assessment of expected heavy water ...

1994-03-01

455

An overview of AECL's participation in the Korean Wolsung Tritium Removal Facility Project (WTRF)  

International Nuclear Information System (INIS)

Full text: In heavy-water-moderated power reactors, tritium is primarily produced by neutron capture in deuterium nuclei in the moderator and coolant. For CANDU 6 reactors, the estimated steady-state values are #approx# 3 TBq#centre dot#kg"-"1 D_2O in the moderator and #approx# 74 GBq#centre dot#kg"-"1 D_2O in the coolant. Tritium removal is one option available to reactor operators for use in their heavy water and tritium management strategies. The WTRF is designed to remove tritium from tritiated heavy water in each of the four CANDU units at the Wolsung Site, to immobilize the tritium and to store it on site. The detritiation process is based on three steps: the first one (front-end) involves the transfer of tritium from heavy water to deuterium gas; the second one (enrichment) concentrates the tritium in a cryogenic distillation system to produce essentially pure D_2 and T_2 streams; and in the ...

2007-11-07

456

Utilization of geothermal energy in the USSR  

International Nuclear Information System (INIS)

This paper reports that at present geothermal energy is utilized in the USSR mostly for district heating, and for industrial and agricultural purposes. The populations of 7 towns have district heating that is supplied by thermal waters. The population supplied totals about 125,000 people. The total area of greenhouses is 850,000 m"2. Electric energy generated at geothermal power stations still remains negligible with the installed capacity of the single Pauzhetka station (Kamchatka) being 11 MW. another station at Mutnovka is currently under construction and is expected to be producing 50 MW by 1992 and 200 MW by 1998. The proven geothermal resources in the USSR provide hope for a significant increase in the utilization of the earth's deep heat in the near future.

1990-08-20

457

The importance of axial effects for borehole design of geothermal heat-pump systems  

Energy Technology Data Exchange (ETDEWEB)

This paper studies the effects of axial heat conduction in boreholes used in geothermal heat pump systems. The axial effects are examined by comparing the results obtained using the finite and infinite line source methods. Using various practical design problems, it is shown that axial effects are relatively important. Unsurprisingly, short boreholes and unbalanced yearly ground loads lead to stronger axial effects. In one example considered, it is shown that the borehole length is 15% shorter when axial conduction effects are considered. In another example dealing with underground water freezing, the amount of energy that has to be removed to freeze the ground is three times higher when axial effects are considered. (author)

2010-04-15

458

Research on the preparation of coal water fuel (CWF) from Banko coal, south Sumatera  

Energy Technology Data Exchange (ETDEWEB)

Studies of CWF preparation at laboratory scale have been carried out using the type and amount of additives and coal content as process variables. Other factors such as particle size, time and rate of stirring were kept constant. CWF with 45 wt% of dry solids, heating value of 5,475 BTU/lb, and stable without the evidence of sedimentation for 9 weeks have been obtained using carboxy methyl cellulose (CMC) as the additive. Low coal content and low heating value can be increased by hydrothermal process on the elevated temperature and pressure. By this process, CWF with dry solid of 55 wt% and a heating value of 7,125 BTU/lb could be obtained. 6 refs., 8 figs., 2 tabs.

1994-01-01

459

Precipitation mechanisms and subsequent hardening kinetics in the #beta#-CEZ alloy  

International Nuclear Information System (INIS)

The #beta#-CEZ alloy : Ti-5%Al-2%Sn-4%Zr-4%Mo-2%Cr-1%Fe is a near #beta# titanium alloy. Since its processing routes include heat treatment (consisting of solution treatment and ageing), it has been decided to study the influence of the #beta# phase stability on #alpha# phase precipitation and hardening kinetics. Small sized specimens, coming from industrial heats, have been heat treated above and below the #beta# transus, and then water quenched. Therefore, several degree of #beta# stability are obtained. When it is increased (i.e. the solution treatment temperature is lowered), #alpha# or #omega# phases precipitations are delayed, as well as the hardening phenomena. Moreover, the #omega# stability domain is reduced. The mechanisms of #alpha# or #omega# precipitation are discussed, and related to the hardening kinetics. (orig.).

460

Clean combustion of solid fuels  

International Nuclear Information System (INIS)

A chemical-looping process is proposed for the clean combustion of solid fuels for electric power or heat generation. The process is based on coal gasification with CO_2 to produce CO. The CO then reduces CaSO_4, which is used as an oxygen carrier, in a separate reactor to give CaS and CO_2. A portion of the CO_2 is recycled for the gasification stage and the rest can be sent for sequestration. The CaS is sent to another reactor for oxidation with air and to generate heat or power. The overall thermal effect is the same as direct combustion, but separation of CO_2 and other pollutants, such as sulphur, is achieved. In comparison with conventional chemical-looping combustion of natural gas, much less water is present in the CO_2 product, and hence the loss of heat energy and corrosion of the fuel-reactor system can be reduced.

2008-01-01

461

Causes of denting. Volume 1. Summary report. Final report  

Science.gov (United States)

This summary report outlines the work that was performed to gain a more complete understanding of denting corrosion of steam generators in PWRs. Background laboratory and plant data on denting were compiled, reviewed and correlated to determine how various exposure conditions affect denting. Two high-temperature chemistry analytical models were reviewed and evaluated by experimental simulation of impurity concentration in the heat transfer and isothermal capsule tests. Simulation of impurity concentration for three cooling waters (lake, river, and cooling tower) was evaluated. The effects of species concentration (Cu/sup + +/, Cl/sup -/, O/sub 2/, and H/sup +/), contaminant thresholds (established by isothermal and heat transfer tests), and heat flux as indicated by superheat on denting were examined. A discussion of several pertinent observations and conclusions drawn from these tasks (as they pertain ...

1984-05-01

462

Analysis of plasma treatment and vapor heat treatment for thin-film transistors by extracting trap densities at front and back interfaces  

International Nuclear Information System (INIS)

Hydrogen (H) plasma treatment, oxygen (O) plasma treatment and water (H_2O)-vapor heat treatment for polycrystalline-silicon (poly-Si) thin-film transistors (TFTs) have been analyzed by separately extracting trap density at a front silicon-oxide interface (D_F) and trap density at a back interface (D_B). It is found that the H plasma treatment is apt to generate D_F and D_B. The O plasma treatment reduces D_F, while the H_2O-vapor heat treatment reduces both D_F and D_B. Improvement of transistor characteristics of poly-Si TFTs depends on understanding these results.

2004-05-17

463

Nuclear desalination for the petrochemical complex of the Natuna project  

International Nuclear Information System (INIS)

On the basis of environmental considerations, a high temperature gas cooled reactor (HTGR) was proposed as the heat source for the Natuna project for CO_2 conversion. To convert CO_2 to useful products, a large amount of high quality water is required for the chemical processes, boilers and other purposes. One LNG production train (maximum of six trains) would produce 0.4 x 10"9 SCF/d of saleable gas and 1.4 x 10"9 SCF/d of CO_2 (in the case of the Exxon process). This CO_2 gas would then be converted to automobile fuel (methane, methanol), which requires a large amount of water. Natural gas from an off- shore gas field is piped to the petrochemical complex on Natuna Island (about 228 km). Natuna is a small island that, apart from sea water, does not have much available water. The desalination process is considered to be the only solution to the water demand ...

1997-12-01

464

Two-step or finite-range effects in charge-exchange reactions  

International Nuclear Information System (INIS)

... charge-exchange reactions dwba finite-range interactions helium 3 reactions

1975-04-07

465

Tests on decisive proof for the incinerating and melting facility using the in-can type high frequency induction heating  

Energy Technology Data Exchange (ETDEWEB)

LEDF(Large Equipment Dismantling Facility) is the solid waste processing technology development facility that carries out high-volume reduction and low dosage processing. The high-volume reduction processing of the high dose {alpha}-waste configured with combustible waste, pvc and rubber, spent ion exchange resin, and noncombustible waste have been planned the incinerating and melting facility using the in-can type high frequency induction heating in LEDF. This test is intended to clarify the design data. It was confirmed that the incinerating and melting performance, molten solid properties and exhaust gas processing performance with pilot testing equipment and bench scale equipment. The result of this test are as follows. 1. Processing speed is 6.7 kg/h for the combustible waste, 13.0 kg/h for the ion exchange resin, and 30.0 kg/h for the noncombustible waste. For above optimum processing conditions are as follows. ...

1999-12-01

466

Purification of radioactive decontamination liquids from NPP Paks with reactive adsorption and ion-exchange process  

International Nuclear Information System (INIS)

In nuclear power plant Paks, Hungary, alkaline oxidative (NaOH, KMnO_4, H_2O) and acidic reductive (citric- and oxalic acid, water) liquids are using for the decontamination of primary circuit equipment (main liquid circulating pumps, steam generators, pipelines etc). The above mentioned decontamination liquids are containing "1"1"0"mAg, "9"5Nb, "5"4Mn, "5"8 Co, "6"0Co, "5"1 Cr, "1"2"4 Sb radioisotopes, summarized radioactivity is between 10"3-8x10"4 kBq/dm"3 liquid. The decontamination liquid can be cleaned with reactive adsorption (active carbon) and ion-exchange process at elevated temperature (333-368 K) in multilayered columns. After purification the summarized radioactivity for "5"4Mn, "6"0Co, and "1"1"0"mAg are in the outlet liquid below 1 kBq/dm"3. Decontamination factor DF#approx =#10"3-10"4, volumetric reduction factor VRF#approx =#50-500.

1999-11-04

467

Proton exchange membrane materials for the advancement of direct methanol fuel-cell technology  

Science.gov (United States)

A new class of hybrid organic-inorganic materials, and methods of synthesis, that can be used as a proton exchange membrane in a direct methanol fuel cell. In contrast with Nafion.RTM. PEM materials, which have random sulfonation, the new class of materials have ordered sulfonation achieved through self-assembly of alternating polyimide segments of different molecular weights comprising, for example, highly sulfonated hydrophilic PDA-DASA polyimide segment alternating with an unsulfonated hydrophobic 6FDA-DAS polyimide segment. An inorganic phase, e.g., 0.5 5 wt % TEOS, can be incorporated in the sulfonated polyimide copolymer to further improve its properties. The new materials exhibit reduced swelling when exposed to water, increased thermal stability, and decreased O.sub.2 and H.sub.2 gas permeability, while retaining proton conductivities similar to Nafion.RTM.. These improved properties may allow direct methanol fuel cells to operate at ...

2006-04-04

468

Physicochemical study of poly(ether ether ketone) electrolyte membranes sulfonated with mixtures of fuming sulfuric acid and sulfuric acid for direct methanol fuel cell application  

International Nuclear Information System (INIS)

Sulfonated poly(ether ether ketone) (SPEEK) membranes with various degrees of sulfonation (DS) have been prepared as a potential membrane material for proton exchange membrane by sulfonation process using mixtures of (15-30% concentration) fuming sulfuric acid and (95-98%) concentrated sulfuric acid as the sulfonating agent. The sulfonation process was conducted at room temperature by varying the acid ratio and reaction time. The produced membranes were then characterized by evaluating the ion exchange capacity (IEC), water uptake, thermal stability, proton conductivity and methanol permeability as a function of degree of sulfonation. The proton conductivity of the sulfonated PEEK membranes with various DS was within the magnitude of 10"-"3 and 10"-"2 S cm"-"1 at room temperature and the methanol permeability was in the range of 3.45 x 10"-"7 to 2.73 x 10"-"6 cm"2 s"-"1. The overall membrane performance of the SPEEK ...

2007-07-15

469

Improvement on CRUD removal efficiency by ion exchange resins  

Energy Technology Data Exchange (ETDEWEB)

Reduction of occupational radiation exposure dose in a BWR plant is achieved by an elimination of crud in a BWR primary loop condensate stream by condensate demineralizer. Crud removal by condensate polisher improves year by year, a phenomenon called the Aging Effect of Ion Exchange Resins. The cause of this phenomenon is assumed to be mainly due to changes in the cation resin property becoming more crud adsorptive, where a typical change in physical property of aged cation resin is an increase in water retention capacity. Assuming that the crud removal efficiency was influenced by a crosslinkage of cation resin, an attempt was made to enhance this removal efficiency by decreasing the crosslinkage and satisfactory results were obtained. As a result, new gel type cation resins were developed with lower crosslinkage and larger surface areas, as compared with conventional gel type resins. The crosslinkage degree of these new cation resins are ...

1989-10-01

470

Improvement on CRUD removal efficiency by ion exchange resins  

International Nuclear Information System (INIS)

Reduction of occupational radiation exposure dose in a BWR plant is achieved by an elimination of crud in a BWR primary loop condensate stream by condensate demineralizer. Crud removal by condensate polisher improves year by year, a phenomenon called the Aging Effect of Ion Exchange Resins. The cause of this phenomenon is assumed to be mainly due to changes in the cation resin property becoming more crud adsorptive, where a typical change in physical property of aged cation resin is an increase in water retention capacity. Assuming that the crud removal efficiency was influenced by a crosslinkage of cation resin, an attempt was made to enhance this removal efficiency by decreasing the crosslinkage and satisfactory results were obtained. As a result, new gel type cation resins were developed with lower crosslinkage and larger surface areas, as compared with conventional gel type resins. The crosslinkage degree of these new cation resins are ...

471

Evaluation of actinide biosorption by microorganisms  

Energy Technology Data Exchange (ETDEWEB)

Conventional methods for removing metals from aqueous solutions include chemical precipitation, chemical oxidation or reduction, ion exchange, reverse osmosis, electrochemical treatment and evaporation. The removal of radionuclides from aqueous waste streams has largely relied on ion exchange methods which can be prohibitively costly given increasingly stringent regulatory effluent limits. The use of microbial cells as biosorbants for heavy metals offers a potential alternative to existing methods for decontamination or recovery of heavy metals from a variety of industrial waste streams and contaminated ground waters. The toxicity and the extreme and variable conditions present in many radionuclide containing waste streams may preclude the use of living microorganisms and favor the use of non-living biomass for the removal of actinides from these waste streams. In the work presented here, we have examined the biosorption of ...

1996-06-01

472

UNSAT-H Version 3.0: Unsaturated Soil Water and Heat Flow Model Theory, User Manual, and Examples  

Energy Technology Data Exchange (ETDEWEB)

The UNSAT-H model was developed at Pacific Northwest National Laboratory (PNNL) to assess the water dynamics of arid sites and, in particular, estimate recharge fluxes for scenarios pertinent to waste disposal facilities. During the last 4 years, the UNSAT-H model received support from the Immobilized Waste Program (IWP) of the Hanford Site's River Protection Project. This program is designing and assessing the performance of on-site disposal facilities to receive radioactive wastes that are currently stored in single- and double-shell tanks at the Hanford Site (LMHC 1999). The IWP is interested in estimates of recharge rates for current conditions and long-term scenarios involving the vadose zone disposal of tank wastes. Simulation modeling with UNSAT-H is one of the methods being used to provide those estimates (e.g., Rockhold et al. 1995; Fayer et al. 1999). To achieve the above goals for assessing water dynamics and estimating ...

2000-06-12

473

The cooperative housing society Vaarst Vestervang - green building; Andelsboligforeningen Vaarst Vestervang - groent byggeri  

Energy Technology Data Exchange (ETDEWEB)

Vaarst Vestervang (Denmark) comprises 16 villas and 1 communal building. The complex was designed by the inhabitants themselves with the aim of polluting the environment as little as possible. The land area constitutes 69.000 square meters where it is possible to grass animals. The document reports a measuring programme concerning the overall heat consumption as one of the main aims of the inhabitants is to save energy and thus contribute to the protection of the environment. The capacity of the solar collectors predominantly used in the building complex was 235 kWh/m{sup 2}. Supplementary heating is provided by boilers fired with wood. The measuring system is described in detail. Tables show the influence of heat transmission losses, ventilation, airing out of rooms, the angle of the sun`s rays within the buildings and heating needs on energy consumption. Energy consumption data is presented in ...

1993-10-01

474

Drying characteristics and nitrogen loss of biogas digestate during drying process  

Energy Technology Data Exchange (ETDEWEB)

The cost of transporting biogas digestate can be decreased by reducing its water content. However, the digestate emits volatile compounds during drying. This study investigated the drying behaviour and the change of digestate composition. Drying took place in a hybrid solar/waste-heat dryer that used solar energy as well as waste heat from a combined heat and power unit (CHP) and the exhaust air of a microturbine. The experiment involved the use of 60 t of liquid digestate. Climatic conditions were measured inside and outside the drying hall. Dry matter (DM) and organic dry matter (ODM) were also measured on a daily basis. In addition, the energy consumption of waste and solar heat were recorded and related to the quantity of dried feedstock. The total nitrogen, ammonium, phosphate, potassium oxide, magnesium oxide and calcium oxide in the digestate were subjected to chemical ...

2010-07-01

475

Augmentation of laminar flow and heat transfer in flat tubes by means of helical screw-tape inserts  

Energy Technology Data Exchange (ETDEWEB)

The heat transfer a characteristics and friction factor in the horizontal double pipes of flat tubes with full length helical screw element of different twist ratio and helical screw inserts with different spacer length are investigated. Cold and hot water are used as working fluid in tube side and shell side respectively. The experiments covered a range of Reynolds numbers 5.7 x 10{sup 2} {<=} Re {<=} 1.31 x 10{sup 3}. The effect of spacer length on the heat transfer augmentation and friction factor and the effect of twist ratio on heat transfer augmentation and friction factor have been presented separately. The study shows that, the Nusslet number (Nu) and friction factor (f) decrease with the increase of S or Y for flat tube. The comparison between the data of present plain circular with that of previous plain circular tube showed a good agreement between them but the data of present ...

2011-01-15

476

Tritium Release Behavior from Li_4SiO_4  

International Nuclear Information System (INIS)

This paper proposes a model to explain tritium release behavior of an irradiated Li_4SiO_4 sample made by Forschungszentrum Karlsruhe. The release curves were obtained in a series of experiments carried out using out-pile temperature programmed desorption techniques in the Kyoto University Reactor (KUR). Tritium release curves obtained for different purge gas compositions (N_2, N_2 + H_2, N_2 + H_2O) were compared for selection of suitable conditions to determine the apparent diffusivity of tritium in a crystal grain of Li_4SiO_4.In the model formation, some mass transfer steps in the bulk of the crystal grain and those on the surface of the grain were taken into account, which were diffusion of tritium in the grain, adsorption and desorption of water on the surface of the grain, two types of isotope exchange reactions, and water formation reaction by the addition of hydrogen to the purge gas.Diffusivities of tritium in the ...

2004-12-01

477

Interfaces in aquatic ecosystems: Implications for transport and impact of anthropogenic compounds  

Energy Technology Data Exchange (ETDEWEB)

Mechanisms that govern transport, accumulation and toxicity of persistent pollutants at interfaces in aquatic ecosystems were the foci of this thesis. Specific attention was paid to humic substances, their occurrence, composition, and role in exchange processes across interfaces. It was concluded that: The composition of humic substances in aquatic surface microlayers is different from that of the subsurface water and terrestrial humic matter. Levels of dissolved organic carbon (DOC) in the aquatic surface microlayer reflect the DOC levels in the subsurface water. While the levels and enrichment of DOC in the microlayer generally show small variations, the levels and enrichment of particulate organic carbon (POC) vary to a great extent. Similarities exist between aquatic surface films, artificial semi-permeable and biological membranes regarding their structure and functioning. Acidification and liming of freshwater ...

1996-11-01

478

Characterization of proton exchange membrane materials for fuel cells by solid state nuclear magnetic resonance  

Energy Technology Data Exchange (ETDEWEB)

Solid-state nuclear magnetic resonance (NMR) has been used to explore the nanometer-scale structure of Nafion, the widely used fuel cell membrane, and its composites. We have shown that solid-state NMR can characterize chemical structure and composition, domain size and morphology, internuclear distances, molecular dynamics, etc. The newly-developed water channel model of Nafion has been confirmed, and important characteristic length-scales established. Nafion-based organic and inorganic composites with special properties have also been characterized and their structures elucidated. The morphology of Nafion varies with hydration level, and is reflected in the changes in surface-to-volume (S/V) ratio of the polymer obtained by small-angle X-ray scattering (SAXS). The S/V ratios of different Nafion models have been evaluated numerically. It has been found that only the water channel model gives the measured S/V ratios in the normal hydration ...

2010-03-15

479

Heat management - a technique for resolving the conflicting aims between fuel consumption and comfort; Waermemanagement - ein Werkzeug zur Loesung der Zielkonflikte zwischen Verbrauch und Komfort  

Energy Technology Data Exchange (ETDEWEB)

In view of current trends in motor car development, the author investigates the increasing conflict between higher comfort and lower fuel consumption. The conflict results mainly from insufficient cooling water heating with consumption-optimized engines. So far, it was never necessary to analyze heat flow after cold starting and heat-up of the powertrain, to develop strategies for heat storage and distribution, to remove heat sinks and to use components multifunctionally. The contribution shows that a general heat management strategy for the whole vehicle will result in high potential fuel savings and improved thermal comfort. Using the example of a latent heat store, heating strategies for the engine and transmission system on the one hand and the passenger compartment on the other hand are ...

1999-07-01

480

Use of semi-detailed kinetic schemes for a study of the temperature dependence in the reforming of fuels without catalyst; L'utilisation de schemas cinetiques semi-detailles pour une etude de l'influence de la temperature dans le reformage de combustibles sans catalyseur  

Energy Technology Data Exchange (ETDEWEB)

In order to avoid the use of catalysts in the process of auto-thermal reforming, it is possible to adopt a running at high temperature. In this study are presented the results of simulations of an auto-thermal/recuperator hybrid reforming system; these results are obtained with the oxidation model of alkanes developed by Ranzi and Faravelli. An isothermal configuration at high temperature improves the hydrogen yield and avoids the formation of soots. The analysis of the powers to be furnished to assure such an experimental mode, and the global approach of the fuel cell system show that the management of the heat exchanges is a key parameter in this process. (O.M.)

2000-07-01

481

Structural material trends in future power plants  

Energy Technology Data Exchange (ETDEWEB)

Future power plants will be more fuel efficient, environmentally benign, and economical than current power plants. A high performance power system (HIPPS), based on a coal-fired combined cycle, is currently being developed. The corrosion and temperature-strength properties of currently available metallic materials limit the maximum efficiency of this cycle. Recently, ceramic matrix composites have shown promise in overcoming the design limitations on the future power plants. In particular, the high-temperature, and corrosion and erosion resistant properties of continuous fiber ceramic composites (CFCCs) will allow engineers to design high-temperature heat exchangers, cyclone vortex finder tubes, and other components. Research being performed to evaluate candidate materials for use in future power plants is discussed.

2000-07-01

482

Jump in the air gasification rate of potassium-doped cellulosic chars  

Energy Technology Data Exchange (ETDEWEB)

Chars prepared from potassium-exchanged carboxy methyl cellulose at several heat treatment temperatures (HTTs) were gasified in air isothermally at selected gasification temperatures (GTs) in the range 633-893 K to investigate the catalytic effectiveness of potassium species. The chars displayed a noticeable jump in gasification rate at a particular gasification temperature (called jump temperature, T{sub j}). The magnitude of jump was much less than that reported for copper and nickel catalysis, but comparable with that for calcium catalysis. Increase in HTT caused a decrease in the jump temperature of chars in contrast with the increase observed in copper, nickel and calcium catalysis; also the magnitude of jump did not decrease, but remained unaltered, on increasing HTT. The different behavior of potassium catalysis is correlated to a change in the chemical state of potassium at higher HTT. The results reveal the dependence of jump ...

2010-12-15

483

Influence of sulfur dioxide content of 20% and 92% sulfuric acid on anodic behavior of stainless steels  

Energy Technology Data Exchange (ETDEWEB)

This paper investigates steels 12Kh18N10T, 10Kh17N13M2T, 08Kh22N6T, and 08Kh21N6M2T. In corrosion of stainless steels in sulfuric acid solutions, dissolved sulfur dioxide acts as a cathodic depolarizer, capable of being reduced to elemental sulfur or forming sulfides with the metal. Depending on the conditions, this is associated with some increase in potential and greater or lesser increase in corrosion or facilitation of passivation of active steel. After passivation the influence of SO/sub 2/ is negligible. The results of this investigation were used as initial data for developing systems of anodic protection for shell-and-tube heat exchangers for sulfuric acid.

1986-07-01

484

High-resolution NMR on /sup 29/Si nuclei in acidic zeolites  

Science.gov (United States)

The effect of treatment of Na-forms of zeolites with HCl solutions and of heat treatment of their NH/sub 4/-forms on the stability of aluminum-oxygen tetrahedra has been studied in this work by high-resolution NMR on /sup 29/Si nuclei, using the synthetic zeolites X, Y, and M (mordenite) as the objects of the study. The exchange capacity with respect to Na/sup +/ ions was determined by analyzing the equilibrium solutions after contact of the samples with 0.5 NH/sub 4/Cl solution on a flame photometer. The high-resolution /sup 29/Si NMR spectra of polycrystalline samples were recorded on an SKhR-200 spectrometer with a superconducting solenoid at a frequency of 39.75 MHz with ultrafast mechanical rotation (3 kHz) of the sample at the magic angle to the external magnetic field. The results obtained are given.

1986-12-01

485

High pressure in situ diffraction studies of metal-hydrogen systems  

British Library Electronic Table of Contents (United Kingdom)

''Hybrid'' hydrogen storage, where hydrogen is stored in both the solid material and as a high pressure gas in the void volume of the tank can improve overall system efficiency by up to 50% compared to either compressed hydrogen or solid materials alone. Thermodynamically, high equilibrium hydrogen pressures in metal-hydrogen systems correspond to low enthalpies of hydrogen absorption-desorption. This decreases the calorimetric effects of the hydride formation-decomposition processes which can assist in achieving high rates of heat exchange during hydrogen loading-removing the bottleneck in achieving low charging times and improving overall hydrogen storage efficiency of large hydrogen stores. Two systems with hydrogenation enthalpies close to -20kJ/mol H2 were studied to investigate the h...

2011-01-01

486

Effective thermal conductivity and thermal contact resistance of gas diffusion layers in proton exchange membrane fuel cells. Part 2: Hysteresis effect under cyclic compressive load  

British Library Electronic Table of Contents (United Kingdom)

Heat transfer through the gas diffusion layer (GDL) is a key process in the design and operation of a PEM fuel cell. The analysis of this process requires the determination of the effective thermal conductivity as well as the thermal contact resistance between the GDL and adjacent surfaces/layers. The Part 1 companion paper describes an experimental procedure and a test bed devised to allow separation of the effective thermal conductivity and thermal contact resistance, and presents measurements under a range of static compressive loads. In practice, during operation of a fuel cell stack, the compressive load on the GDL changes. In the present study, experiments are performed on Toray carbon papers with 78% porosity and 5% PTFE under a cyclic compressive load. Results show a significant hy...

2010-01-01

487

Effective thermal conductivity and thermal contact resistance of gas diffusion layers in proton exchange membrane fuel cells. Part 1: Effect of compressive load  

British Library Electronic Table of Contents (United Kingdom)

Heat transfer through the gas diffusion layer (GDL) is a key process in the design and operation of a PEM fuel cell. The analysis of this process requires determination of the effective thermal conductivity as well as the thermal contact resistance associated with the interface between the GDL and adjacent surfaces/layers. In the present study, a custom-made test bed that allows the separation of effective thermal conductivity and thermal contact resistance in GDLs under vacuum and ambient conditions is described. Measurements under varying compressive loads are performed using Toray carbon paper samples with a porosity of 78% for a range of thicknesses. The measurements are complemented by compact analytical models that achieve good agreement with experimental data. A key finding is that ...

2011-01-01

488

Corrosion in steam generators of PWR type nuclear power plants  

International Nuclear Information System (INIS)

Problems are discussed of heat exchange tubes of Westinghouse type vertical steam generators exhibiting corrosion damage such as point corrosion, planar corrosion, tube denting, corrosion stress cracking, crevice corrosion, fretting corrosion and intergranular corrosion. Attention is also paid to problems of WWER-440 type horizontal steam generators, where the level fluctuation area is critical; noncompact porous deposits of the corrosion products give rise to crevice effects and cause significant concentration of chloride ions and other additions. This problem can be partly resolved by a modification of the collector design at the level variation area. An additional measure is the production of steel 08Kh18N10T with a very low level of harmful elements and inclusions. (Z.M.). 3 figs., 11 refs.

1988-03-01

489

Analysis of steam generator loss-of-feedwater experiments with APROS and RELAP5/MOD3.1 computer codes  

Energy Technology Data Exchange (ETDEWEB)

Three experiments were conducted to study the behaviour of the new horizontal steam generator construction of the PACTEL test facility. In the experiments the secondary side coolant level was reduced stepwise. The experiments were calculated with two computer codes RELAP5/MOD3.1 and APROS version 2.11. A similar nodalization scheme was used for both codes so that the results may be compared. Only the steam generator was modeled and the rest of the facility was given as a boundary condition. The results show that both codes calculate well the behaviour of the primary side of the steam generator. On the secondary side both codes calculate lower steam temperatures in the upper part of the heat exchange tube bundle than was measured in the experiments. (orig.) 4 refs.

1997-12-01

490

Analysis of steam generator loss-of-feedwater experiments with APROS and RELAP5/MOD3.1 computer codes  

International Nuclear Information System (INIS)

Three experiments were conducted to study the behaviour of the new horizontal steam generator construction of the PACTEL test facility. In the experiments the secondary side coolant level was reduced stepwise. The experiments were calculated with two computer codes RELAP5/MOD3.1 and APROS version 2.11. A similar nodalization scheme was used for both codes so that the results may be compared. Only the steam generator was modeled and the rest of the facility was given as a boundary condition. The results show that both codes calculate well the behaviour of the primary side of the steam generator. On the secondary side both codes calculate lower steam temperatures in the upper part of the heat exchange tube bundle than was measured in the experiments. (orig.).

1995-09-10

491

Alloy 800 welding experience at UKAEA Springfields  

International Nuclear Information System (INIS)

Investigatins into the welding of alloy 800 at the Reactor Fuel Element Laboratories, Springfields, commenced about three years ago following an extended development programme on tube to tube plate welding of low alloy and stainless steels for the Prototype Fast Reactor. The techniques and approach developed for critical fuel element welding applications had proved equally suitable for the precision welding requirements on the much heavier sections of heat exchangers. It had been demonstrated that the same control of weld quality and profile could be achieved with consistency and the permissible range of critical parameters could be readily defined. Because of this, development work was continued to include other materials, such as alloy 800, which might be of potential use. The tungsten inert gas (T.I.G.) arc welding process is used, and the equipment, including the control system, is described. Tube to tube-plate welding, and tube to tube ...

492

Manitoba Hydro's earth power program and Manitoba market update  

International Nuclear Information System (INIS)

An outline of Manitoba Hydro's Earth Power program was presented. Details of the heat pump market in Manitoba were provided, including details of residential and commercial sales. Total residential heat pump sales amounted to 577 units in 2004, equivalent to over $11.2 million in sales. Commercial installations amounted to approximately $12.7 million. An outline of industry players was presented. The goals of Manitoba Hydro were outlined in relation to geothermal energy and the Power Smart program. Their objectives included increasing awareness of geothermal energy, making heat pumps more accessible, and improving industry infrastructure. Other objectives included educating the public about life-cycle cost implications, residential loans and commercial incentives. To date, the residential power loan has provided financing to over 300 Manitoba home owners for installations, with electrical savings of over 1.34 Gwh and ...

2005-02-24

493

Improvement in efficiency and savings potentials at the ''cold end'' by means of tube cleaning and cooling water filtration; Wirkungsgradverbesserung und Einsparpotentiale am ''kalten Ende'' durch Rohrreinigung und Kuehlwasserfiltration  

Energy Technology Data Exchange (ETDEWEB)

Contamination and blockages of the cooling tubes in the turbine condenser disturb the heat transfer, thereby causing power losses at the turbine and increasing the fuel demand. Corrosions cause tubing leakages which require operating downtimes and reduce the lifetime of the pipes. Tube cleaning systems and backflushing cooling water filters eliminate these problems. Nevertheless it can come to coatings in the condenser tubes, if the tube cleaning equipment does not operate optimally or if coarse dirt is entered. Under this aspect, the author of the contribution under consideration reports on these problems on the basis of practical examples. The author gives references to the optimized operation of the tube cleaning system and the cooling water filtration.

2010-07-01

494

Gibbs ensemble Monte Carlo simulations of coexistence properties of a polarizable potential model of water  

Energy Technology Data Exchange (ETDEWEB)

The liquid/vapor coexistence density, the partial vapor pressure, and the heat of vaporization were calculated using Gibbs ensemble Monte Carlo simulation techniques. Long-range interactions such as charge-charge, charge-dipole, and dipole-dipole were evaluated using Ewald summation techniques. A polarizable potential model was used to describe the water-water interactions (Dang and Chang, J. Chem. Phys. 106, 8149, 1997). The model yields good agreement with the corresponding experimental data in the lower temperature region and moderate agreement in the higher temperature region. The critical temperature and density were estimated to be 565 K and 0.28 g/cm3.

2001-12-01

495

Evaporation behavior of water and concentration of technetium and rhenium using thin film evaporator  

International Nuclear Information System (INIS)

The nuclear energy cycle requires the recycling of nuclear fuel, water, chemical reagents, and the volume reduction of radioactive liquid wastes. A fundamental technique for continuous recovery of water using a thin-film evaporator was examined. Appropriate recovery measurements were: an evaporator heat temperature of 323 K, a feed rate of 0.23 cm"3 x s"-"1, a vacuum pressure of 15 mmHg (2 kPa), and impeller rotational speeds of 500#approx#600 rpm (min"-"1). The concentration of trace technetium and rhenium in aqueous solutions was also studied. A decontamination factor of 10"5 for rhenium was obtained. (author)

1999-06-01

496

Estimation of dry rubber content in natural rubber latex by differential scanning calorimetry  

British Library Electronic Table of Contents (United Kingdom)

Differential Scanning Calorimetry (DSC) is employed to study the changes in enthalpy of natural rubber latex samples when heated under a controlled temperature program. It is found that the mass normalized areas of the DSC curves between room temperature and 170??C for different latex samples are inversely proportional to the dry rubber content (DRC) of the samples, measured following the weighing and drying method. The changes in total enthalpy of the samples in this temperature range are interpreted as due to the variations in the quantity of water present in the samples. The measurements have been repeated by diluting selected samples with known quantities of water, and it is found that the normalized areas of the DSC curves are directly proportional to the amount of water added to the ...

2010-01-01

497

Emergency core cooling system  

International Nuclear Information System (INIS)

Purpose: To obtain stabilized operation by preventing over heat in emergency cooling pumps upon accidents of flow regulators. Constitution: A pressure suppression chamber pool and a pressure vessel are communicated to each other with a pipeway and the water in the suppression pool is charged by a charging pump to the pipeway. The pipeway is interposed with an emergency cooling pump so as to feed water in the pipeway to the pressure vessel and a water source and the emergency cooling pumps are connected by way of a closed pipeway. Further, the closed pipeway and the pipeway interposed with the charging pump are communicated to each other by way of a connecting pipeway, to which are interposed an instrument for detecting the increase in the temperature of the emergency cooling pumps due to abnormality in the closed pipe (such as troubles in flow regulators) and outputting control signals and an ...

498

Abundance of Alnus incana ssp. rugosa in Adirondack Mountain shrub wetlands and its influence on inorganic nitrogen  

Energy Technology Data Exchange (ETDEWEB)

The presence of the nitrogen-fixing shrub, Alnus incana ssp. rugosa, influences the concentration of inorganic nitrogen in surface waters in the Adirondack Mountain region of northern New York. - The purpose of this research was to determine the abundance of the nitrogen-fixing shrub, Alnus incana ssp. rugosa (speckled alder), in shrub wetlands of the Adirondack Mountain region of New York State and to determine whether its abundance affects the concentration or accumulation of inorganic nitrogen in wetland substrates. Alder/willow wetlands are the second most common wetland type in the Adirondack region. The Adirondack Park Agency's digital GIS database of wetland types was used to determine the areal extent of alder/willow wetlands in the Adirondacks. Randomly selected wetlands were sampled to determine the size and abundance of alder. Alder densities averaged {approx}7000 stems ha{sup -1} and alder was present in 75% of the wetlands. As an indication of ...

2003-06-01

499

Comparing Maintenance Costs of Geothermal Heat Pump Systems with other HVAC Systems in Lincoln Public Schools: Repair, Service, and Corrective Actions  

Energy Technology Data Exchange (ETDEWEB)

The Lincoln Public School District, in Lincoln, Nebraska, recently installed vertical-bore geothermal heat pump systems in four, new, elementary schools. Because the district has consistent maintenance records and procedures, it was possible to study repair, service and corrective maintenance requests for 20 schools in the district. Each school studied provides cooling to over 70% of its total floor area and uses one of the following heating and cooling systems: vertical-bore geothermal heat pumps (GHPs), air-cooled chiller with gas-fired hot water boiler (ACUGHWB), water-cooled chiller with gas-fired hot water boiler (WCCYGHWB), or water-cooled chiller with gas-fired steam boiler (WCUGSB). Preventative maintenance and capital renewal activities were not included in the available database. GHP schools reported average total costs at 2.13 ...

1999-06-19