WorldWideScience
1

Surge-line thermal stratification: Displacements and fatigue damage computations  

Energy Technology Data Exchange (ETDEWEB)

Slow, unexpected displacements have been experienced in most pressurized water reactor (PWR) surge lines. Sometimes, these displacement lead to gap closure at the pipe whip restraints. These movements occur because of thermal stratification. This movement has the potential to increase stresses to valves, which may exceed the material yield stress. To understand this phenomenon, Framatome, Commissariat a l'Energie Atomique, and Electricite de France have undertaken large programs for the study of (1) thermal-hydraulic tests with a half-scale Plexiglas surge line, (2) thermal-hydraulic computations of permanent states and transients with a two-dimensional model, and (3) mechanical analysis of displacements and computation of fatigue damage due to stratification. This paper deals with the last subject. Avoiding stratification in piping by process modifications is difficult because of the high flow ...

1989-01-01

2

Investigation of the removal efficiency of gasborne particles in a scrubber column  

Energy Technology Data Exchange (ETDEWEB)

Tests on the scrubbing column have led to the following results: Use of a scrubbing column with Raschig rings is only meaningful for the sedimentation of particles exceeding diameters of 0.5 ..mu..m; drops of diameter size 1.5 ..mu..m are formed in the column; more efficient drop precipitators in the column air flow ease the load on subsequent suspended material filters thereby contributing to a longer life of these filters even at higher sodium ion concentrations in the washing water; with distillate of an 8% rather than 0.8% salt solution a decontamination factor greater than 10 can be calculated since larger particles precipitate more readily. This only applies, however, under the condition that the washing water is renewed regularly, if necessary daily where higher aerosol concentrations are present. If not, the decontamination factor will be reduced through ...

1983-01-01

3

Investigation of the removal efficiency of gasborne particles in a scrubber column  

International Nuclear Information System (INIS)

Tests on the scrubbing column have led to the following results: Use of a scrubbing column with Raschig rings is only meaningful for the sedimentation of particles exceeding diameters of 0.5 #mu#m; drops of diameter size 1.5 #mu#m are formed in the column; more efficient drop precipitators in the column air flow ease the load on subsequent suspended material filters thereby contributing to a longer life of these filters even at higher sodium ion concentrations in the washing water; with distillate of an 8% rather than 0.8% salt solution a decontamination factor greater than 10 can be calculated since larger particles precipitate more readily. This only applies, however, under the condition that the washing water is renewed regularly, if necessary daily where higher aerosol concentrations are present. If not, the decontamination factor will be reduced through the ...

4

Industrial application of green chromatography-I. Separation and analysis of niacinamide in skincare creams using pure water as the mobile phase  

British Library Electronic Table of Contents (United Kingdom)

In this work, chromatographic separation of niacin and niacinamide using pure water as the sole component in the mobile phase has been investigated. The separation and analysis of niacinamide have been optimized using three columns at different temperatures and various flow rates. Our results clearly demonstrate that separation and analysis of niacinamide from skincare products can be achieved using pure water as the eluent at 60^oC on a Waters XTerra MS C18 column, a Waters XBridge C18 column, or at 80^oC on a Hamilton PRP-1 column. The separation efficiency, quantification quality, and analysis time of this new method are at least comparable with those of the traditional HPLC methods. Compared with traditional HPLC, the major advantage of this newly developed green chromatography techniq...

2011-01-01

5

Diurnal variation of phytoplankton community in a high frequency area of HABs: Daya Bay, China  

British Library Electronic Table of Contents (United Kingdom)

Phytoplankton community was investigated in the cage culture area of Daya Bay during a diurnal cycle. Two rainfalls occurred during the course of the experiment and decreased the surface seawater salinity in the aquaculture area. A total of 38 species were identified, of which the dominant species included Pseudo-nitzschia spp. and Skeletonema costatum. Water stratification obstructed the vertical migration of dinoflagellates. Statistical analysis indicated that Synechococcus showed negative relationship with silicate and ammonia, which indicated that Synechococcus adapted to grow at oligotrophic environment. Phytoplankton community structure implied the risk of Pseudo-nitzschia spp. blooms in the aquaculture area of Daya Bay.

2011-01-01

6

Coolant stratification and its thermohydrodynamic specificity under natural circulation in horizontal steam generator collectors  

Energy Technology Data Exchange (ETDEWEB)

The experiments and the test facilities for the study of the stratification phenomenon in the hot plenum of reactor and the upper parts of the steam generator collectors in a nuclear power plant are described. The aim of the experiments was to define the conditions of the stratification initiation, to study the temperature field in the upper part, the definition of the characteristics in the stratification layer, and also to study the factors which cause the intensity of the stagnant volume cooling.

1997-12-31

7

Mathematical modeling of a direct contact humidification?dehumidification desalination process  

British Library Electronic Table of Contents (United Kingdom)

Using air as a carrier gas is common in humidification?dehumidification desalination processes. A computer program was written using mass and energy balances for modeling the process behavior. The parameters considered in this work were inlet air and fresh water recycle temperatures, inlet air flow rate, saline water and fresh water recycle flow rates, and saline water to air flow ratio. Results of simulation showed that increasing inlet air and fresh water recycle flow rate increases fresh water production. It was also found that heating the inlet air to humidification column or cooling the inlet water to dehumidification column increases the production rate but increasing water to air flow ratio in a humidifier leads to a lower production rate. The predicted effects of the ...

2009-01-01

8

Laboratory differential simulation design method of pressure absorbers for carbonization of phenolate solution by carbon dioxide in coal-tar processing  

Energy Technology Data Exchange (ETDEWEB)

A laboratory differential simulation method is used for the design of carbonization columns at coal-tar processing in which phenols are regenerated from phenolate solution by carbon dioxide absorption. The design method is based on integration of local absorption rates of carbon dioxide along the column. The local absorption rates into industrial phenolate mixture are measured in a laboratory model contactor for various compositions of the gas and liquid phases under the conditions that ensure the absorption rates in the laboratory absorber simulate the local rates in the industrial column. On the bases of the calculations, two-step carbonization columns were designed for 30000 t/year of the phenolate solution treatment by carbon dioxide. The absorption proceeds at higher pressure of 500 kPa and temperatures from 50 to 65 C, pure carbon dioxide is used and toluene is added. These conditions have the ...

2009-01-15

9

Turbulence in the positive column of a glow discharge  

CERN Document Server

Turbulence in the positive column of a glow discharge

1969-01-01

10

Reply to comment on "A simple model for the short-time evolution of near-surface current and temperature profiles"  

CERN Document Server

This is our response to a comment by Walter Eifler on our paper `A simple model for the short-time evolution of near-surface current and temperature profiles' (arXiv:physics/0503186, accepted for publication in Deep-Sea Research II). Although Eifler raises genuine issues regarding our model's validity and applicability, we are nevertheless of the opinion that it is of value for the short-term evolution of the upper-ocean profiles of current and temperature. The fact that the effective eddy viscosity tends to infinity for infinite time under a steady wind stress may not be surprising. It can be interpreted as a vertical shift of the eddy viscosity profile and an increase in the size of the dominant turbulent eddies under the assumed conditions of small stratification and infinite water depth.

2005-01-01

11

Experimental investigation of spray induced gas stratification break-up and mixing in two interconnected vessels  

British Library Electronic Table of Contents (United Kingdom)

To analyze the effect of containment spray on gas mixing and depressurization, two experiments (ST3_1 and ST3_2) were performed with two interconnected vessels. These experiments were conducted in the frame of the OECD/SETH-2 project using the PANDA facility. The vessels were preconditioned such that a helium-rich layer is formed in the upper section of the first vessel, henceforth referred to as Vessel-1. In the case of the first experiment (ST3_1), the remaining volume of Vessel-1 and the entirety of the second vessel, Vessel-2, were filled with pure steam. For ST3_2, the second experiment presented here, pure steam was replaced with a steam-air mixture instead. Water was injected from the top of Vessel-1 with a spray nozzle projecting downwards. Transient behavior of system pressure, as...

2011-01-01

12

Conceptual design of a nuclear reactor facility for medical and biological purposes  

Energy Technology Data Exchange (ETDEWEB)

Optimal neutron energy for boron neutron capture therapy (BNCT) has been studied. Epithermal neutron is superior to thermal neutrons in treating deep-seated tumors. Design of the epithermal neutron column for BNCT has been performed by using a two-dimensional transport calculation code. Aluminum and heavy water are used as moderation materials. A thermal neutron column is also designed using heavy water as thermalization material. The configuration of the facility for treatment and research of BNCT and also for basic radio-biological studies of neutrons has been presented.

1981-09-01

13

Conceptual design of a nuclear reactor facility for medical and biological purposes  

International Nuclear Information System (INIS)

Optimal neutron energy for boron neutron capture therapy (BNCT) has been studied. Epithermal neutron is superior to thermal neutrons in treating deep-seated tumors. Design of the epithermal neutron column for BNCT has been performed by using a two-dimensional transport calculation code. Aluminum and heavy water are used as moderation materials. A thermal neutron column is also designed using heavy water as thermalization material. The configuration of the facility for treatment and research of BNCT and also for basic radio-biological studies of neutrons has been presented. (author).

14

Chromate Transport through Surfactant-Modified Zeolite Columns  

British Library Electronic Table of Contents (United Kingdom)

Abstract Remediation of ground water containing anionic contaminants presents a great challenge. Because of its low cost, surfactant-modified zeolite (SMZ) has been studied for >10 years for potential uses as permeable barrier materials to remove anionic contaminants from water. In this study, zeolite aggregates with particle size of 3.4 to 4.8 mm were modified by hexadecyltrimethylammonium (HDTMA) bromide, a cationic surfactant, to a surfactant loading level of 80 mmol/kg and a concurrent counterion bromide loading level of 34 mmol/kg. While no retardation of chromate transport was observed for unmodified columns, a retardation factor of 60 was found for chromate transport through the SMZ columns. Slow but persistent desorption of HDTMA occurred throughout the chromate transport experimen...

2006-01-01

15

Observations of unsaturated water flow using real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography was demonstrated to be a viable and useful tool in studying water flow in unsaturated media. The experiment was designed to test the method for following water flow. The wetting front advance, water-flow patterns, and neutron attenuation density were observed in a 7.7-cm diameter sand column. The advance was fit with a simple i = A t/sup B/ equation yielding an excellent correlation. Theoretical calculations presented estimate the minimum and maximum detectable water content in various sizes of columns. The ability of real-time neutron radiography to allow both qualitative and quantitative spatial and time measurements to be made in an nonintrusive manner was demonstrated.

1987-08-01

16

Observations of unsaturated water flow using real-time neutron radiography  

International Nuclear Information System (INIS)

Real-time neutron radiography was demonstrated to be a viable and useful tool in studying water flow in unsaturated media. The experiment was designed to test the method for following water flow. The wetting front advance, water-flow patterns, and neutron attenuation density were observed in a 7.7-cm diameter sand column. The advance was fit with a simple i = A t/sup B/ equation yielding an excellent correlation. Theoretical calculations presented estimate the minimum and maximum detectable water content in various sizes of columns. The ability of real-time neutron radiography to allow both qualitative and quantitative spatial and time measurements to be made in an nonintrusive manner was demonstrated.

1987-01-01

17

Possible Stratification Mechanism in Granular Mixtures  

CERN Document Server

We propose a mechanism to explain what occurs when a mixture of grains of different sizes and different shapes (i.e. different repose angles) is poured into a quasi-two-dimensional cell. Specifically, we develop a model that displays spontaneous stratification of the large and small grains in alternating layers. We find that the key requirement for stratification is a difference in the repose angles of the two pure species, a prediction confirmed by experimental findings. We also identify a kink mechanism that appears to describe essential aspects of the dynamics of stratification.

1997-01-01

18

About technical possibility to use VEERA facility for investigation of coolant stratification phenomenon in horizontal steam generators  

Energy Technology Data Exchange (ETDEWEB)

The presentation gives a brief insight on possibility of using the VEERA facility in studying the stratification phenomenon. The idea for such experiments is to use the facility upper plenum part to simulate the conditions in upper part of horizontal steam generator hot collector. The upper part of steam generator hot collector is one of the locations where the stratification can take part during natural circulation mode. 4 refs.

1997-12-31

19

Enantioselective separation of the carfentrazone-ethyl enantiomers in soil, water and wheat by HPLC  

British Library Electronic Table of Contents (United Kingdom)

A simple enantioselective HPLC method was developed for measuring carfentrazone-ethyl enantiomers. The separation and determination was accomplished on an amylose tris[(S)-a-methylbenzylcarbamate] (Chiralpak AS) column using n-hexane/ethanol (98:2, v/v) as mobile phase at a flow rate of 1.0 mL/min with UV detection at 248 nm. The effects of mobile-phase composition and column temperature on the enantioseparation were discussed. The accuracy, precision, linearity, LODs, and LOQ of the method were also investigated. LOD was 0.001 mg/kg in water, 0.015 mg/kg in soil and wheat, with an LOQ of 0.0025 mg/kg in water and 0.05 mg/kg in soil and wheat for each enantiomer of carfentrazone-ethyl. SPE was used for the enrichment and cleanup of soil, water, and wheat samples. Recoveries for two enantio...

2010-01-01

20

Multiple Ion Exchange Column Tests for Technetium Removal from Hanford Tank Waste Supernate  

Science.gov (United States)

Five cycles of loading, elution, and regeneration were performed to remove technetium from a Hanford waste sample retrieved from Tank 241-AW-101 using SuperLig 639 resin. The waste sample was diluted to 4.95 M Na plus and then was processed to remove 137Cs through dual ion exchange columns each containing 15 mL of SuperLig 644. To remove 99Tc, the cesium decontaminated solution was processed downwards through two ion exchange columns, each containing 12 mL of SuperLig 639 resin. The columns, designated as lead and lag, each had an inside diameter of 1.45 cm and a height of 30 cm. The columns were loaded in series, but were eluted and then regenerated separately. The average technetium loading for the cycles was 250 BV at 10 percent breakthrough. There was no significant difference in the loading performances among the five cycles. The percent removal of 99Tc was greater than 99.94 percent and the ...

2004-02-27

21

Separation of the components of the binary mixture ethanol-water by steam flux in solid phase column; Separacao dos componentes da mistura binaria etanol-agua por passagem do vapor em coluna de fase solida  

Energy Technology Data Exchange (ETDEWEB)

This paper deals with the energy required to separate ethanol from an aqueous solution in a distillation column containing a solid phase. The solid phases evaluated consisted of either an amylatious (ground corn) or a cellulose (sugar cane bagasse) absorber whit particle sizes smaller than 4 mm. The water-retention capacity of each solid phase was measured by passing vapors or ethanol-water mixtures through the solid phase. When starting with initial concentrations bellow the azeotropic point, ethanol concentrations up to 99,5% (on corn) and 97,2% (on sugar cane) were achieved. The water content was evaluated potentiometrically (Karl`Fischer). Regarding the 2-4 mm ground corn solid phase column, the energy consumed was estimated to be reduced by 15,6% and 60% (by weight) ethanol-water mixture respectively. (author) 11 refs., 2 figs., 2 tabs

1987-12-31

22

A mathematical model for a thermally coupled humidification?dehumidification desalination process  

British Library Electronic Table of Contents (United Kingdom)

The humidification?dehumidification process is an interesting technique that has been adapted for water desalination. Previous works experimentally investigated desalination processes in the shell and tube columns, where the humidification and dehumidification were thermally coupled and simultaneously performed at the tube and shell sides, respectively. In this work, a comprehensive steady-state mathematical model was developed for such a humidification?dehumidification desalination process by taking into account the heat and mass balances on both sides of the desalting column, the mass transfer rate at the humidification side, and the heat transfer rate between the dehumidification side and humidification side. Meanwhile, the mass transfer coefficient at the humidification side and the to...

2006-01-01

23

Simple calculation of daily photosynthesis by means of five photosynthesis-light equations  

Energy Technology Data Exchange (ETDEWEB)

The performance of five well-known photosynthesis-light equations is compared by presenting a wide range of solutions in the form of dimensionless nomographs for the case where photosynthetically available radiation (PAR) reduces exponentially down the water column and is distributed sinusoidally through the photoperiod. These provide a simple means of calculating daily photosynthesis at any depth (e.g. at a benthic layer), or through a water column, avoiding the need to perform complex integrations. An examination is made of the accuracy of common approximate methods for calculating daily photosynthesis, assuming constant PAR. For optically deep water a modification is proposed to Talling's planimetric solution, to enable daily photosynthesis to be calculated more accurately, yet simply, over the whole range of possible PAR values. The errors induced by approximating the ...

1992-12-01

24

PANDA passive decay heat removal transient test results  

International Nuclear Information System (INIS)

PANDA is a large scale facility for investigating the long-term decay heat removal from the containment of a next generation of 'passive' Advanced Light Water Reactors (ALWR). PANDA was used to examine the long-term LOCA response of the Passive Containment Cooling System (PCCS) for the General Electric (GE) Simplified Boiling Water Reactor (SBWR). The first PANDA test series had the dual objectives of demonstrating the performance of the SBWR PCCS and extending the data base available for containment analysis code qualification. The test objectives also include the study of the effects of mixing and stratification of steam and noncondensible gases in the drywell (DW) and in the suppression chamber or wetwell (WW). Ten tests were conducted in the course of the PANDA SBWR Program. The tests demonstrated a favorable and robust overall PCCS performance under different conditions. The present paper focuses on the main phenomena ...

25

Boiler and HRSG tube failures. Lesson 2. Corrosion fatigue  

Energy Technology Data Exchange (ETDEWEB)

Fatigue damage occurs in general when a boiler tube is subject to repeat cyclic or fluctuating loading although the stress produced is below the material yield strength. The types of fatigue damage include, e.g., corrosion, thermal, mechanical, vibration, and creep fatigue. It is important to determine which form of fatigue is active, because measures to avoid repeat failures differ as the case arises. In this lesson, the focus is exclusively on corrosion fatigue. Corrosion fatigue occurs by the combined synergistic actions of cyclic loading and a corrosive environment. It is a discontinuous process with crack initiation and growth during transient periods. The excessive stresses may be caused during boiler operation by the restraint at tube attachments and by load changes (in particular during cold starts or forced cools) or during shutdown or restart of circulation boilers by thermal stratification of water along the tube length. Poor ...

2009-10-15

26

Strontium-90 and cesium-137 in service water from June to December, 1981  

International Nuclear Information System (INIS)

Service water, 100 l each, was collected at an intake of a water treatment plant and at a tap after water was left running for five minutes. The carriers of strontium and cesium were added to water immediately after sampling, and the sample was vigorously stirred and filtered. Then it was passed through a cation exchange column at a rate of 80 ml/min. Strontium and cesium were eluted with hydrochloric acid from the cation exchange column, and separated. After the radiochemical separation, the mounted precipitates were counted for activity using low background beta counters normally for 60 min. Net sample counting rates were corrected for counter efficiency, recovery, self absorption and decay to obtain the content of strontium-90 and cesium-137 radioactivity per sample aliquot. From the results, concentrations of these nuclides in the original sample were ...

1981-12-01

27

Gadolinium removal from the moderator system of TAPP - 3 using the three layer bed  

International Nuclear Information System (INIS)

Nitric acid leaching from the weak base anion (WBA) exchanger had been evaluated and based on this a 5% mixture of nitric acid loaded weak base anion exchanger with fresh weak base anion exchanger (NLWBA) at the bottom of the ion exchange column has been devised to maintain an outlet pH in the range of 5.0 to 5.5 during Gd removal from the moderator system of TAPP - 3 and 4. A three layered bed had been constituted wherein strong acid cation (SAC) exchanger is placed as the top layer while a mixed bed of SAC and WBA or pure WBA is used as the middle layer and the 5% NLWBA was used as the bottom most layer. This bed configuration would result in an iso-pH regime in the moderator system during the Gd removal along with quantitative removal of Gd. Two three-layer bed columns were prepared at TAPS - 3 and 4 in July 07. The resin was loaded in batches and after preparing the column, the column was deuterated ...

2008-12-01

28

The Performance Evaluation of a Hot Water Layer using a Numerical Simulation  

International Nuclear Information System (INIS)

Most of all research reactors are immerged in the deep water pool to be a ultimate heat sink. At the neighbor of the reactor, some radio-active matters, such as Na-24, Ar-41, Mg-27, Al-28 and etc, may be generated by the neutron irradiation. Those radio-active isotopes may rise up to the pool water surface through the natural convection flow, which can make the radioactivity in the reactor hall rise high enough to concern about the health of people working in the reactor hall. When the irradiation test facilities are loaded or unloaded during a normal operation, the highly radio-activated primary coolant may flow out through the irradiation test holes on the top of the reactor. This also may be a main hazard source to make the working environment of the reactor hall bad. Making a hot water layer 1.5 ? 2.0 m thick at the top of reactor pool would be a good measure to resolve that problem. The hot water ...

2009-05-01

29

Modification of ion-exchange resin composition for the removal of Gd of higher (15 ppm) concentration from moderator system of 540 MWe PHWRs  

International Nuclear Information System (INIS)

Addition of Gadolinium Nitrate as chemical shim to moderator heavy water of 540 MWe PHWR, at 15 mg/kg level (at a pH of 5.0) is practiced for reactor shutdown purposes. Presently a strong acid cation exchanger column is used for this purpose. During this operation, the moderator pH of 3.8, with the IX column outlet pH of ?3.5-3.6 was observed against the technical specification demand that when Gd is present, the pH of moderator must be in the range of 5.0-5.5. In order to achieve an iso-pH regime during Gd removal, studies were conducted using a mixed bed of strong acid cation resin plus a weak base anion resin (loaded in the volume ratio of 1 : 6), backed up in the same column (bottom most layer) by a 5 % nitric acid loaded weak base resin and topped by a strong acid cation resin (uppermost layer) simulating system flow velocity and percentage loading of resin. Using such a column ...

2006-11-13

30

Segmentation and fragmentation of melt jets due to generation of large-scale structures. Observation in low subcooling conditions  

Energy Technology Data Exchange (ETDEWEB)

In order to clarify a mechanism of melt-jet breakup and fragmentation entirely different from the mechanism of stripping, a series of experiments were carried out by using molten tin jets of 100 grams with initial temperatures from 250degC to 900degC. Molten tin jets with a small kinematic viscosity and a large thermal diffusivity were used to observe breakup and fragmentation of melt jets enhanced thermally and hydrodynamically. We observed jet columns with second-stage large-scale structures generated by the coalescence of large-scale structures recognized in the field of fluid mechanics. At a greater depth, the segmentation of jet columns between second-stage large-scale structures and the fragmentation of the segmented jet columns were observed. It is reasonable to consider that the segmentation and the fragmentation of jet columns are caused by the boiling of water ...

1999-07-01

31

Development of ultrafiltration and adsorbents: October 1979-March 1980  

Energy Technology Data Exchange (ETDEWEB)

Tests on a sample of trench water from the Maxey Flats burial ground effectively demonstrated the new Reverse Osmosis Pilot Plant. The effluent from the 50% salt-rejection membrane was decontaminated well enough with the exception of tritium to be discharged to the environment. The performance of the 97% salt-rejection membrane was superior to that of the 50% membrane. A breakthrough and capacity experiment was conducted with Durasil 10 on a simulated Three Mile Island solution. The maximum decontamination factor was extrapolated to be 10/sup 6/, which would reduce the cesium level of TMI water to below the discard limit. Capacity (1/DF = 0.5) was reached at 1260 column volumes. Several adsorbents were tested in the engineering columns for decontamination of cesium-bearing solutions. Under the conditions of the experiment, these adsorbents were ineffective in removing cesium from the solution.

1980-07-02

32

On Sensitivity of Spectral Radiative Fluxes to Atmospheric Water Vapor in the 940 nm Region (Numerical Simulation)  

Energy Technology Data Exchange (ETDEWEB)

Water vapor is well known to be a critical component in many aspects of atmospheric research, such as radiative transfer and cloud and aerosol processes. This requires both improved measurements of the columnar water vapor and its profiles in the atmosphere in a wide range of conditions, and adjustment of water vapor parameterizations in radiation codes including the perfection of spectroscopic parameters. In this paper we will present the results of comparison of our calculations and downward solar fluxes measured with Rotating Shadowband Spectroradiometer under conditions of horizontally homogeneous clouds. We also will discuss the sensitivity of atmospheric radiation characteristics to variations of water vapor in the band 940 nm: these results may be useful for development of new methods of retrieval of the total column water vapor content (WVC) in the ...

2005-03-18

33

Large temperature differential thermal storage system. Its design and evaluation  

Energy Technology Data Exchange (ETDEWEB)

A large temperature differential (10K) thermal storage system in a small (4400 m{sup 2}) 8-storey office building is discussed and the monitoring results are analyzed in comparison with computer simulations. Requirements were a comfortable indoor environment and system cost effectiveness. Out of four potential system concepts, the Large Temperature Differential System was chosen. It comprises a flat-type thermal stratification heat storage tank in the under floor pit of the building as the heat source for a variable flow heat pump chiller. The heat sink is a set of serially connected air handling and fan coil units. The tank`s capacity is sized for one day operation and is made as large as possible to shift the electricity demand to night time. To avoid a large size and high cost, the water temperature differential was enlarged. The role of Tokyo Electric Power Company (TEPCO) was to develop the chiller and its control system. It is concluded ...

1996-07-01

34

Low temperature humidification dehumidification desalination process  

Energy Technology Data Exchange (ETDEWEB)

The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling ...

2006-03-01

35

Low temperature humidification dehumidification desalination process  

International Nuclear Information System (INIS)

The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling ...

2006-03-01

36

Reductive dechlorination of chlorinated solvents by zero-valent iron, iron oxide and iron sulfide minerals  

Energy Technology Data Exchange (ETDEWEB)

The degradation of chlorinated solvents by reduction at the surface of zero-valent metals and bimetallic systems has emerged as an important approach to the in-situ remediation of ground water. Reduction by iron metal was studied in batch and column systems to develop a mechanistic understanding of the reaction chemistry and to determine the factors that affect dechlorination rate and long term performance in field applications.

1996-10-01

37

Design of absorption columns in the presence of surfactants  

Energy Technology Data Exchange (ETDEWEB)

An equation is described to estimate the value of the liquid-phase mass-transfer coefficient of aqueous solutions of surfactants from its value for pure water. The form of the equation is obtained from Levich's theory, and it is adjusted to experiments of absorption of CO/sub 2/ in aqueous solutions of five pure surfactants. The reduction of the absorption rate is correlated with the interfacial pressure of the solution.

1986-01-01

38

Early Dynamic Risk Stratification with Baseline Troponin Levels and 90-minute ST Segment Resolution to Predict 30 Day Cardiovascular Mortality in STEMI: Analysis from CLARITY TIMI-28  

UK PubMed Central (United Kingdom)

BackgroundTroponin is the preferred biomarker for risk stratification in non-ST-elevation ACS. The incremental prognostic utility of the initial magnitude of troponin...Full Text Available

2010-06-01

39

Mass transfer and sorptive properties of geological samples from the Drigg site  

Energy Technology Data Exchange (ETDEWEB)

This report presents the results of an experimental programme to determine the mass transfer and sorptive properties of selected glacial sand and clays from the Drigg Disposal Site operated by British Nuclear Fuels plc. The hydraulic conductivity of both the sand and clay has been determined and the sensitivity of this parameter to changing water chemistry investigated. The hydrodynamic dispersion properties of the glacial sand were measured in order to aid the interpretation of column sorption experiments. The sorption of strontium and uranium from groundwater onto clay and sand samples has been studied using through-diffusion, column and batch techniques. Employing the batch technique, the effect of a series of humic acid concentrations on distribution ratios for uranium and plutonium has also been investigated. Groundwater and trench leachate were used with both clay and sand. (author).

1990-02-01

40

Determination of carboxylic acids in oxidised engine oils by liquid chromatography with cemiluminiscence detection  

Energy Technology Data Exchange (ETDEWEB)

A procedure for the determination of carboxylic acids (benzoic and C{sub 8}-C{sub 16} aliphatic acids) in oxidised engine oils is described. It is based on a simple and selective derivatisation of the acids with a fluorescent label 9-anthracene-methanol followed by reverse-phase separation on an ODS column with a water-acetonitrile-tetrahydrofuran (20:40:40 by volume) mobile phase and post-column reaction with bis(2,4-dinitrophenyl) oxalate and hydrogen peroxide. The chemiluminiscence emission from the reaction was monitored using a lamina flow-through detector. Analysis of oxidised oils showed that although there was quenching of chemiluminiscence emission by the oil matrix, the acids could be determined over the range 0-0.4% (m/v) in the oil with a detection limit of 0.013% (m/v) (130 pmol on-column with a 20 {mu}l injection) for lauric acid. 8 figs., 2 tabs., 17 refs.

1992-09-01

41

Desorption of polycyclic aromatic hydrocarbons (PAH`s) from calcite and quartz sediments to seawater  

Energy Technology Data Exchange (ETDEWEB)

Polycyclic aromatic hydrocarbons (PAH`s) are ubiquitous hydrophobic organic pollutants in the marine environment. Many of the PAM`s are classified as possible carcinogens or mutagens, therefore they are of considerable concern to human and environmental health. The highest concentrations are found in coastal regions due to anthropogenic activities including oil spills, tanker operations, incomplete fossil fuel combustion and runoff. The sources and distribution of PAM`s in sediments are fairly well known, while the fate and transport of PAH`s in the marine environment are less known. Desorption is an important factor influencing the fate and transport of hydrophobic molecules at the seawater/sediment interface. The desorption of PAH`s from contaminated marine sediments to the water column/pore water affects the availability of the pollutant to biota. The sorption of PAH`s is determined in part by the organic carbon content ...

1996-12-31

42

Analytical study on integrity of BWR reactor internal structures against water hammer under RIA conditions  

Energy Technology Data Exchange (ETDEWEB)

The integrity of the RPV head and reactor internals was assessed by means of fluid-structural analyses using a coupled method to evaluate the water hammer phenomenon arising from high burnup fuel failure under RIA conditions. The fluid viscosity effect on the water column burst as well as the complex three-dimensional flow paths caused by a core shroud and standpipes were considered in this study. The three analysis scenarios were designed to investigate the above mentioned influential factors separately. In the first scenario, a two-dimensional axisymmetric reactor vessel model without any reactor internals was modeled to assess the influence of the fluid dynamics in the NSC RIA regulatory evaluation. This model has an actual RPV geometry and can be simply separated from other influential factors in order to concentrate only on investigation of the fluid viscosity effect. In the second scenario, a two-dimensional ...

2003-07-01

43

Contaminant assimilation in newly created prairie wetlands  

Energy Technology Data Exchange (ETDEWEB)

Increased use of wetlands for habitat and water quality improvement emphasize the need for further study of abiotic-biotic interactions in these systems. This research examined contaminant assimilation within the water column of two newly created Colorado prairie wetlands (RMA3 and RMA4). To examine the influence of abiotic factors (e.g., alkalinity, suspended solids), ten chronic toxicity tests were performed from December 1991 through November 1993. In the first set of tests, Ceriodaphnia dubia were exposed to water from the two wetlands which was spiked with various concentrations of zinc. These tests suggested that water from RMA4 had higher contaminant assimilative capacity than water from RMA3. Preliminary analysis suggested suspended solids, pH, conductivity, and temperature were important factors affecting neonate production by C. dubia when exposed to ...

1994-12-31

48

Effects of a mixture of tetracyclines to Lemna gibba and Myriophyllum sibiricum evaluated in aquatic microcosms  

Energy Technology Data Exchange (ETDEWEB)

The impact of a mixture of oxytetracycline, chlortetracycline, tetracycline and doxycycline on Myriophyllum sibiricum and Lemna gibba was investigated using fifteen 12,000-L microcosms (k = 5, n = 3). Significant concentration-response relationships were only found for M. sibiricum, where dry mass was 69, 47, 30, and 7% of controls at respective treatment concentrations of 0.080, 0.218, 0.668, and 2.289 {mu}mol/L. Somatic endpoints were strongly and negatively correlated with percent light transmission, except plant length, which was positively correlated. Treated microcosms experienced a reduction in the percent of surface irradiance penetrating the water column as high as 99.8% at a depth of 70 cm, relative to controls. Position relative to the water column was likely responsible for the differential effects observed between floating (L. gibba) and submerged (M. sibiricum) species of macrophytes. A ...

2005-12-15

49

Anaerobic treatment of wastewater from a food-manufacturing plant with a low concentration of organic matter and regeneration of usable pure water  

Energy Technology Data Exchange (ETDEWEB)

Wastewater from a food-manufacturing plant with a low concentration of organic matter was treated at 37 centigrade in an anaerobic fluidized-bed reactor or in an upflow anaerobic sludge blanket. As the influent TOC (total organic carbon) concentration decreased, the TOC removal efficiency in these reactors decreased from 85% to 65%. The concentration of suspended solids in the effluent could be reduced to 20 mg/l, which corresponded to 7% of that in the influent. The effluent from both reactors was treated aerobically in a fixed-bed reactor. The TOC concentration and optical density of effluent from the aerobic treatment were reduced to 5 mg/l and 0.005, respectively. When the effluent treated anaerobically or aerobically was passed over an activated carbon column, the effluent TOC concentration was reduced to 2 to 3 mg/l. The conductivity in raw wastewater was remarkably reduced on an ion-exchange resin column. Ultra-pure ...

1994-03-25

50

Modeling of thermal and hydrodynamic aspects of molten jet/water interactions  

Energy Technology Data Exchange (ETDEWEB)

In order to predict the effect of a fuel-coolant interaction after a hypothetical core-melt-down accident, a phenomenological model has been developed to describe the thermal and hydrodynamic behavior of a high-temperature molten jet when it interacts with saturated or subcooled water in a film boiling regime. The mechanisms of jet-material erosion were analyzed by Kelvin-Helmholtz instabilities on the coherent column and by boundary layer stripping on the leading edge. The heat transfer coefficient, vapor-film thickness, and net steam generation, all of which strongly affect the jet-breakup behavior, were solved analytically. It was found that the jet breakup (or erosion) depends strongly on the steam generation from the jet/water interaction. The jet-breakup length (i.e., penetration distance) was found to be sensitive to the initial jet temperature, water subcooling, and the physical state of the ...

1989-01-01

51

Analytical surveys on water quality of Trasimeno Lake: Definition of trophic levels; Indagine sulla qualita` delle acque del Lago Trasimeno: Definizione dei livelli trofici  

Energy Technology Data Exchange (ETDEWEB)

The previous judgment of eutrophic state, once proposed for the Trasimeno Lake (Umbria region, Italy), has been revised. According to Vollenweider-OECD classification criterion, the lake waters are at present to be classified as mesotrophic waters, with phosphorus limitation. However this level of moderate productivity results to be conditioned by the hydrochemical characteristics of the lake waters, that control phosphorus concentrations independently from the loading coming from the basin, and prevent dangerous and massive algal blooms. Different processes of chemical nature, regulating the phosphorus amount in the lake waters, are then reviewed: adsorption of P/P0(4) onto suspended materials, particularly clay mineral particles, and direct precipitation as hydroxylapatite or co-precipitation with carbonates, are found to be the principal mechanisms that determine chemical removal of phosphorus from ...

1995-06-01

52

Solid-state ozone synthesis by energetic ions  

International Nuclear Information System (INIS)

We have synthesized ozone by irradiating thin solid films of oxygen and oxygen-water mixtures with 100 keV protons, motivated by recent reports of condensed O_3 on icy satellites in the outer Solar system. We measured the depth of the Hartley absorption band in the ultraviolet by reflectance spectroscopy and used it to quantify the column density of ozone. We analyzed the results using a three-component (O, O_2 and O_3) model that successfully explains the fluence dependence of ozone production.

1999-08-02

53

An investigation of the retention of some radioelements on natural fibers  

International Nuclear Information System (INIS)

The retention of radio-Eu, Go, Cs and Sr, at the tracer level, on raw fibers produced from hemp, linen and Jute plants was investigated. The study was conducted from different media including: sea and tap waters, sodium chloride and nitric acid solutions of different Ph. The percentage retention and elution, on prolonged contact, varied from one element to another depending on conditions. Extraction chromatography columns, using these fibers as supporting material were also experimented. Results were discussed together with possible applications. 7 tabs.

54

Social Change and Socioeconomic Disparities in Health over the Life Course in China: A Cohort Analysis  

UK PubMed Central (United Kingdom)

This article examines social stratification in individual health trajectories for multiple cohorts in the context of China’s dramatically changing macro-social environment. Using data...Full Text Available

2010-02-01

55

MODFLOW 2.0: A program for predicting moderator flow patterns  

Energy Technology Data Exchange (ETDEWEB)

Sudden changes in the temperature of flowing liquids can result in transient buoyancy forces which strongly impact the flow hydrodynamics via flow stratification. These effects have been studied for the case of potential flow of stratified liquids to line sinks, but not for moderator flow in SRS reactors. Standard codes, such as TRAC and COMMIX, do not have the capability to capture the stratification effect, due to strong numerical diffusion which smears away the hot/cold fluid interface. A related problem with standard codes is the inability to track plumes injected into the liquid flow, again due to numerical diffusion. The combined effects of buoyant stratification and plume dispersion have been identified as being important in operation the Supplementary Safety System which injects neutron-poison ink into SRS reactors to provide safe shutdown in the event of safety rod failure. The MODFLOW code discussed here provides ...

1991-07-01

56

MODFLOW 2. 0: A program for predicting moderator flow patterns  

Energy Technology Data Exchange (ETDEWEB)

Sudden changes in the temperature of flowing liquids can result in transient buoyancy forces which strongly impact the flow hydrodynamics via flow stratification. These effects have been studied for the case of potential flow of stratified liquids to line sinks, but not for moderator flow in SRS reactors. Standard codes, such as TRAC and COMMIX, do not have the capability to capture the stratification effect, due to strong numerical diffusion which smears away the hot/cold fluid interface. A related problem with standard codes is the inability to track plumes injected into the liquid flow, again due to numerical diffusion. The combined effects of buoyant stratification and plume dispersion have been identified as being important in operation the Supplementary Safety System which injects neutron-poison ink into SRS reactors to provide safe shutdown in the event of safety rod failure. The MODFLOW code discussed here provides ...

1991-07-01

57

Impact of Proteinuria and Glomerular Filtration Rate on Risk of Thromboembolism in Atrial Fibrillation: the ATRIA Study  

UK PubMed Central (United Kingdom)

BackgroundAtrial fibrillation (AF) substantially increases the risk of ischemic stroke but this risk varies among individual patients with AF. Existing risk stratification...Full Text Available

2009-03-17

58

Crud removal performance with ion exchange resins in BWR plants  

Energy Technology Data Exchange (ETDEWEB)

It is needless to say that one of the most important roles of the condensate demineralizer in Japanese boiling water reactors (BWR) is to eliminate such impurities during accidental occurrence of sea water leakage from condensate cooling system. Ion exchange resins packed in condensate demineralizer have also been expected to decrease crud, or corrosion products (CP) in condensate water in order to finally reduce activated corrosion products (ACP) in the reactor coolant loop. It is perceived that crud removal ability of a condensate demineralizer has been improved year by year. And we call this phenomenon as `Aging Effect`. Typical property changes of aged cation exchange resin consisted of an increase of water retention capacity and a change of surface texture. Based on these findings, we formulated a new concept and developed new gel type ion exchange resins for the better crud removal. The results ...

1996-01-01

59

Real-time neutron radiography for visualisation of interfacial geometry and phase distribution in two-phase flow  

International Nuclear Information System (INIS)

Results of ongoing research project at the McMaster Nuclear Reactor Facility on real-time neutron radiography for the visualization of interfacial geometry, movements and phase distributions in gas-liquid and gas-liquid-metal multi-phase flows are presented. Experiments were conducted with bubble column tubes with boiling liquid nitrogen, air-water and air-mercury mixtures. Discussions are also focused on air-water flowing within a tube containing a CANDU type 37 rod fuel bundle assembly positioned both horizontally and vertically. Computer processing using a digital image format to enhance the real-time images was used. Imaging techniques include frame averaging, background substraction, edge enhancement (spatial filtering), contrast enhancement and video densitometry. (orig.).

1989-10-01

60

Investigation of a hydraulic impact: a technology in rock breaking  

CERN Document Server

The finite element method and dimensional analysis have been applied in the present paper to study a hydraulic impact, which is utilized in a non-explosive rock breaking technology in mining industry. The impact process of a high speed piston on liquid water, previously introduced in a borehole drilled in rock, is numerically simulated. The research is focused on the influences of all the parameters involved in the technology on the largest principal stress in the rock, which is considered as one of the key factors to break the rock. Our detailed parametric investigation reveals that the variation of the isotropic rock material properties, especially its density, has no significant influence on the largest principal stress. The influences of the depth of the hole and the depth of the water column are also very small. On the other hand, increasing the initial kinetic energy of the piston can dramatically increase the largest ...

2009-01-01

61

Non-standard natural circulation in primary circuit of VVR-440, behavior of horizontal steam generator in this regime  

Energy Technology Data Exchange (ETDEWEB)

Analyzing various SBLOCA with high pressure safety injection (HPSI) at VVER-440/213, we met a surprising phenomenon - a 'natural' circulation post SG heat transfer reversal. This is not usual, because normal natural circulation (NC) in primary circuit is connected with positive heat transfer at SG. If there is reverse heat transfer at SG (as soon as the break enthalpy outflow is sufficient for removal of reactor decay heat), it should obstruct any natural circulation. The question was, what is the driving force of this 'non-standard natural circulation'. After all we revealed that force - it is the density difference between the colder water in reactor downcomer (cold water from HPSI) and warmer water in inner reactor (lower plenum, core, upper plenum). This phenomenon could be confusing for operating personal, because there would be an opposite temperature difference at the loop than by ...

2001-07-01

62

Non-standard natural circulation in primary circuit of VVR-440, behavior of horizontal steam generator in this regime  

International Nuclear Information System (INIS)

Analyzing various SBLOCA with high pressure safety injection (HPSI) at VVER-440/213, we met a surprising phenomenon - a 'natural' circulation post SG heat transfer reversal. This is not usual, because normal natural circulation (NC) in primary circuit is connected with positive heat transfer at SG. If there is reverse heat transfer at SG (as soon as the break enthalpy outflow is sufficient for removal of reactor decay heat), it should obstruct any natural circulation. The question was, what is the driving force of this 'non-standard natural circulation'. After all we revealed that force - it is the density difference between the colder water in reactor downcomer (cold water from HPSI) and warmer water in inner reactor (lower plenum, core, upper plenum). This phenomenon could be confusing for operating personal, because there would be an opposite temperature difference at the loop than by normal natural circulation (under ...

2001-03-20

63

Development on the cryogenic hydrogen isotopes distillation process technology for tritium removal (Final report)  

Energy Technology Data Exchange (ETDEWEB)

While tritium exposure to the site-workers in Wolsung NPP is up to about 40% of the total personnel exposure, Ministry of Science and Technology has asked tritium removal facility for requirement of post heavy-water reactor construction. For the purpose of essential removal of tritium from the Wolsung heavy-water reactor system, a preliminary study on the cryogenic Ar-N{sub 2} and H{sub 2}-D{sub 2} distillation process for development of liquid-phase catalytic exchange cryogenic hydrogen distillation process technology. The Ar-N{sub 2} distillation column showed good performance with approximately 97% of final Ar concentration, and a computer simulation code was modified using these data. A simulation code developed for cryogenic hydrogen isotopes (H{sub 2}, HD, D{sub 2}, HT, DT, T{sub 2}) distillation column showed good performance after comparison with the result of a JAERI code, and a H{sub 2}-D{sub ...

1995-12-01

64

Desorption of uranium from titanium-activated carbon composite adsorbent with acidic eluent, 2  

Energy Technology Data Exchange (ETDEWEB)

The desorption of uranium from the granular titanium-activated carbon composite adsorbent (concentration of uranium: 25.5 mg/l-Ad), which adsorbed uranium from natural sea water, was examined by the column process with acidic eluent at room temperature. The column operation was able to be carried out without destruction of the granular adsorbent by the generation of the carbon dioxide, and free from disturbance of the eluent flow by precipitate of calcium sulfate dihydrate with sulfuric acid eluent. The amount of acid consumption by the adsorbent was 0.87 eq/l-Ad. The alkaline earth metals were eluted in the range of elution volume below 2l/l-Ad, whereas uranium, iron, and titanium were eluted above 2l/l-Ad. Therefore, uranium was separable from the alkaline earth metals which were adsorbed in the most quantity in the adsorbent. In the range of elution volume 2 to 12l/l-Ad, the percentage of desorbed uranium and the ...

1984-01-01

65

Acid mine drainage and its impact in the Black Creek watershed, Virginia  

International Nuclear Information System (INIS)

A one-year study was conducted to determine the impacts of acid min drainage (AMD) on the Black Creek watershed in Wise County, Virginia. Water quality, metal content of sediment and water column, soil pH, macroinvertebrate assemblages, habitat assessment and toxicity testing were used to assess the impact in the watershed. A total of 22 sites in the creek and surrounding watershed were actively monitored. This included six primary sources of AMD. Conductivity measurements > 1,000 microhmos/cm were found at eight sites and pH was consistently below 6.0 at seven. Of six metals analyzed, magnesium was highest in the water column, ranging from 16.5 mg/L to 130 mg/L. Aluminum and iron were both elevated in the sediment with iron concentrations as high as 176,000 mg/kg. An increase in sediment metal concentrations was noted when progressing downstream in the creek. Of nine high wall ...

1996-11-17

66

The Relationships between Xylem Safety and Hydraulic Efficiency in the Cupressaceae: The Evolution of Pit Membrane Form and Function1[W][OA  

Science.gov (United States)

Water transport in conifers occurs through single-celled tracheids that are connected to one another via intertracheid pit membranes. These membranes have two components: the porous margo, which allows water to pass through the membrane, and the impermeable torus, which functions to isolate gas-filled tracheids. During drought, tracheids can become air filled and thus hydraulically dysfunctional, a result of air entering through the pit membrane and nucleating cavitation in the water column. What are the hydraulic tradeoffs associated with cavitation resistance at the pit level, and how do they vary within the structural components of the intertracheid pit? To address these questions, we examined pit structure in 15 species of Cupressaceae exhibiting a broad range of cavitation resistances. Across species, cavitation resistance was most closely correlated to the ratio of the torus to pit aperture ...

2010-08-15

67

Studies of the behaviour of technical chemicals introduced into the subsoil under modelled conditions  

International Nuclear Information System (INIS)

Because of the environmental hazard of organic solvents such as chlorinated or aromatic hydrocarbons, water soluble and biodegradable substitutes have come into use. It should be assessed how they affect soil and aquifer when spilled in leaks or accidents. This was simulated in a model system using methanol and percolation columns, one filled with material from the unsaturated subsurface and two with different materials from aquifers. The results reveal that a spill of the substitutes can also cause problems. In homogeneous soils and at long retention times until the substance reaches the aquifer, sorption and biological degradation are most likely to prevent contamination of the groundwater. When oxygen supply in the subsurface is insufficient, reducing conditions occur and sulphide is formed. The data show that much more methanol was eliminated than reflected by the consumption of electron acceptors. This indicates that sorption and anabolic ...

1993-04-01

68

Report on Thermo-Hydro-Mechanical Laboratory Tests Performed by CIEMAT on Febex Bentonite 2004-2008  

International Nuclear Information System (INIS)

The results of the laboratory studies performed by CIEMAT with the FEBEX bentonite in the context of WP3.2 of the NF-PRO Project and of the Agreement ENRESA-CIEMAT Anexo V are presented and analysed in this report. They refer to the effect of the hydraulic gradient on the permeability of bentonite, the effect of the thermal gradient on the hydration kinetics of bentonite, and the repercussion of temperature on the hydro-mechanical properties of bentonite (swelling, permeability and water retention capacity). In all the cases the bentonite has been used compacted to densities expected in the engineered barrier of a high-level radioactive waste repository. The existence of threshold and critical hydraulic gradients has been observed, both of them dependent on bentonite density and water pressures. After more than seven years of hydration, the 40-cm high bentonite columns are far from full saturation, the thermal gradient ...

69

Report on Thermo-Hydro-Mechanical Laboratory Tests Performed by CIEMAT on Febex Bentonite 2004-2008  

Energy Technology Data Exchange (ETDEWEB)

The results of the laboratory studies performed by CIEMAT with the FEBEX bentonite in the context of WP3.2 of the NF-PRO Project and of the Agreement ENRESA-CIEMAT Anexo V are presented and analysed in this report. They refer to the effect of the hydraulic gradient on the permeability of bentonite, the effect of the thermal gradient on the hydration kinetics of bentonite, and the repercussion of temperature on the hydro-mechanical properties of bentonite (swelling, permeability and water retention capacity). In all the cases the bentonite has been used compacted to densities expected in the engineered barrier of a high-level radioactive waste repository. The existence of threshold and critical hydraulic gradients has been observed, both of them dependent on bentonite density and water pressures. After more than seven years of hydration, the 40-cm high bentonite columns are far from full saturation, the thermal gradient ...

2009-11-25

70

The thermal response of an infinite line of open loop wells for ground coupled heat pump systems  

British Library Electronic Table of Contents (United Kingdom)

Ground thermal energy storage is a means of storing thermal energy underground during the summer and utilizing it during the winter. The main use of such a technology is in the heating, ventilating and air conditioning sector where the ground provides a stable temperature reservoir for a heat pump system. Heat pumps are mechanical systems that provide heating to a space in the winter, and cooling in the summer. They are increasingly popular because the same system provides both heating modes, depending on the direction of the cycle upon which they operate. The stable temperature reservoir allows the heat pump system to run at a higher efficiency. Thermal energy is transmitted to and from the ground by circulation of water through standing column geothermal wells. In commercial applications...

2011-01-01

71

Preliminary studies on the chemical characterization and antioxidant properties of acidic polysaccharides from Sargassum fusiforme  

British Library Electronic Table of Contents (United Kingdom)

In order to investigate the antioxidant properties of the polysaccharides from the brown alga Sargassum fusiforme, the crude polysaccharides from S. fusiforme (SFPS) were extracted in hot water, and the lipid peroxidation inhibition assay exhibited that SFPS possessed a potential antioxidant activity. Hence, two purely polymeric fractions, SFPS-1 and SFPS-2 were isolated by the column of DEAE (2-diethylaminoethanol)-Sepharose Fast Flow, with their molecular weights of 51.4 and 30.3 kDa determined by high performance gel permeation chromatography (HPGPC). They were preliminarily characterized using chemical analysis in combination of infrared (IR) and nuclear magnetic resonance (NMR) spectroscopies and found to contain large amounts of uronic acids and ?-glycosidical linkages. The antioxida...

2008-01-01

72

Modelling the reworking effects of bioturbation on the incorporation of radionuclides into the sediment column: implications for the fate of particle-reactive radionuclides in Irish Sea sediments  

British Library Electronic Table of Contents (United Kingdom)

A microcosm laboratory experiment was conducted to determine the impact of biological reworking by the ragworm Nereis diversicolor on the redistribution of particle-bound radionuclides deposited at the sediment-water interface. Over the course of the 40-day experiment, as much as 35% of a 137Cs-labelled particulate tracer deposited on the sediment surface was redistributed to depths of up to 11 cm by the polychaete. Three different reworking models were employed to model the profiles and quantify the biodiffusion and biotransport coefficients: a gallery-diffuser model, a continuous sub-surface egestion model and a biodiffusion model. Although the biodiffusion coefficients obtained for each model were quite similar, the continuous sub-surface egestion model provided the best fit to the data...

2010-01-01

73

Laboratory-scale simulation of energy extraction from tidal currents  

Energy Technology Data Exchange (ETDEWEB)

The energy available from tidal currents is substantial and considerable work has been conducted into determining the size of the resource and what the large-scale consequences of extraction might be. This paper describes the work conducted to establish a laboratory-scale model, by using the commercial computational fluid dynamics (CFD) code FLUENT trademark, in order to predict local-flow consequences resulting from the extraction of energy in two and three dimensions from within the water column in a tidal flow. As might be expected, a wake is formed but there is considerable localized flow acceleration around and, most especially, under an extraction zone. The wake behind the device is shown to be associated with a drop in the free surface which, in turn, is associated with the decline in the wake itself. (author)

2008-06-15

74

Determination of low-molecular-weight organic acids and inorganic anions by gradient elution chromatography  

Energy Technology Data Exchange (ETDEWEB)

Conditions of the separation and detection of organic and inorganic anions by gradient ion chromatography and suppressed conductivity detection were studied, and the procedure of gradient elution was optimized. A detection limit of 1 x 10{sup -3} {mu}g x L{sup -1} was obtained using the pre-concentrated column and most relative standard deviations obtained in the determination of seven organic and inorganic anions were below 5%. This method was proved to be simple, rapid and accurate for the separation and determination of low-molecular-weight organic acids and inorganic anions and could be applied in the analysis of the samples from water and steam systems of thermal power plants with satisfactory results. (orig.)

2007-03-15

75

Combining innovative technology demonstrations with dense nonaqueous phase liquids cleanup  

Energy Technology Data Exchange (ETDEWEB)

Radioactively contaminated acidic aqueous wastes and organic liquids were discharged to the soil column at three disposal sites within the 200 West Area of the Hanford Site, Washington. As a result, a portion of the underlying groundwater is contaminated with carbon tetrachloride several orders of magnitude above the maximum contaminant level accepted for a drinking water supply. Treatability testing and cleanup actions have been initiated to remove the contamination from both the unsaturated soils to minimize further groundwater contamination and the groundwater itself. To expedite cleanup, innovative technologies for (1) drilling, (2) site characterization, (3) monitoring, (4) well field development, and (5) contaminant treatment are being demonstrated and subsequently used where possible to improve the rates and cost savings associated with the removal of carbon tetrachloride from the soils and groundwater.

1993-05-01

76

Chemical absorption of carbon dioxide with aqueous sodium hydroxide solution spray  

Energy Technology Data Exchange (ETDEWEB)

Measurements of local mass fluxes of liquid, local number fluxes of the drop and local drop size distributions at various locations in the test column were made for wide ranges of liquid flow rates and gas flow rates. An empirical correlation for the volume mean diameter of the drop at the nozzle exit was proposed. Measurements of the rates of absorption of carbon dioxide from carbon dioxide-air mixtures with water sprays (physical absorption) and aqueous sodium hydroxide sprays (chemical absorption) were made for wide range so fluid flow rates, feed gas concentrations, and initial alkali concentrations. The observed dimensionless rates of absorption were compared with the theoretical values by assuming penetration model with second-order irreversible reaction. 11 refs., 7 figs.

1996-12-31

77

An overview of AECL's participation in the Korean Wolsung Tritium Removal Facility Project (WTRF)  

International Nuclear Information System (INIS)

Full text: In heavy-water-moderated power reactors, tritium is primarily produced by neutron capture in deuterium nuclei in the moderator and coolant. For CANDU 6 reactors, the estimated steady-state values are #approx# 3 TBq#centre dot#kg"-"1 D_2O in the moderator and #approx# 74 GBq#centre dot#kg"-"1 D_2O in the coolant. Tritium removal is one option available to reactor operators for use in their heavy water and tritium management strategies. The WTRF is designed to remove tritium from tritiated heavy water in each of the four CANDU units at the Wolsung Site, to immobilize the tritium and to store it on site. The detritiation process is based on three steps: the first one (front-end) involves the transfer of tritium from heavy water to deuterium gas; the second one (enrichment) concentrates the tritium in a cryogenic distillation system to produce essentially pure D_2 and T_2 streams; and in the ...

2007-11-07

78

Treatment of Produced Waters Using a Surfactant Modified Zeolite/Vapor Phase Bioreactor System  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes work performed on this project from October 2004 through March 2005. In previous work, a surfactant modified zeolite (SMZ) was shown to be an effective system for removing BTEX contaminants from produced water. Additional work on this project demonstrated that a compost-based biofilter could biodegrade the BTEX contaminants found in the SMZ regeneration waste gas stream. However, it was also determined that the BTEX concentrations in the waste gas stream varied significantly during the regeneration period and the initial BTEX concentrations were too high for the biofilter to handle effectively. A series of experiments were conducted to determine the feasibility of using a passive adsorption column placed upstream of the biofilter to attenuate the peak gas-phase VOC concentrations delivered to the biofilter during the SMZ regeneration process. In preparation for the field test of the SMZ/VPB treatment system in New Mexico, ...

2005-03-11

85

Evaluation of a permeable reactive barrier technology for use at Rocky Flats Environmental Technology Site (RFETS)  

Energy Technology Data Exchange (ETDEWEB)

Three reactive materials were evaluated at laboratory scale to identify the optimum treatment reagent for use in a Permeable Reactive Barrier Treatment System at Rocky Flats Environmental Technology Site (RFETS). The contaminants of concern (COCS) are uranium, TCE, PCE, carbon tetrachloride, americium, and vinyl chloride. The three reactive media evaluated included high carbon steel iron filings, an iron-silica alloy in the form of a foam aggregate, and a peculiar humic acid based sorbent (Humasorb from Arctech) mixed with sand. Each material was tested in the laboratory at column scale using simulated site water. All three materials showed promise for the 903 Mound Site however, the iron filings were determined to be the least expensive media. In order to validate the laboratory results, the iron filings were further tested at a pilot scale (field columns) using actual site water. Pilot test results ...

2000-01-01

86

Development on the technologies for tritium removal processes  

Energy Technology Data Exchange (ETDEWEB)

While tritium exposure to the site-workers in Wolsung NPP is upto about 40 % of the total personnel exposure, Korea Institute of Nuclear Safety has asked tritium removal facility, as one of the requirements for post reactor construction, after operation of four CANDU reactors in Wolsung site. For the purpose of essential removal of tritium from the heavy water system of the heavy water reactors, an experiment of Ar-N{sub 2} cryogenic distillation tower was carried out as a preliminary study for development of liquid-phase catalytic exchange - cryogenic hydrogen distillation process. The steady-state reached after 50 minutes under 90 K in the Ar-N{sub 2} distillation column (inner diameter 20 mm, height 500 mm) packed with Dixon ring ({phi} 3 mm x H 3 mm), and the ratios of Ar-concentration at the top and at the bottom measured by gas chromatography within {+-}1 % relative error was approximately 93 : 3. This value was ...

1994-12-01

87

Reducing the effect of penstock pressure pulsations on hydro electric plant power system stabilizer signals  

Energy Technology Data Exchange (ETDEWEB)

A characteristic trait of Francis turbines operating at low-head is pressure pulsations that occur during certain load levels of the generator. These stem from pressure variations across the turbine due to pulsating flow in the draft-tube. This surging action of the water column is related to draft-tube geometry and flow-rate of water in the penstock. The pressure pulsations cause torque variations on the turbine and corresponding electric power pulsations. If electric power is used as a feedback signal to the Power System Stabilizer (PSS), then Mvar and terminal voltage pulsations will occur when the generator is operating in the ``rough zone``. This paper describes field test results for investigating feedforward control from the penstock, draft tube and spiral case pressure to reduce the effects of Mw pulsations on PSS output signals. This investigation involved a PSS with generator power as the feedback signal and the ...

1993-12-01

88

Improvement of leaching characteristics of TOC from condensate demineralizers  

International Nuclear Information System (INIS)

Recent nuclear power plants require high purity water to protect nuclear reactors or steam generators from SCC and maintain in good condition. In this connection, it is especially important to minimize sulfate, which is a corrosive chemical originated from oxidative degradation of cation exchange resins during operation. Recently, uniform particle size (UPS) strong acid cation gel resin with 14% cross-linkage, which has excellent stability against oxidization, has been applied to several condensate purification systems. For further improvement of water quality, some methods for changing the configuration of condensate demineralizer's resin bed have been examined. For example, these methods correspond to anion under layer and cation over layer. We have tested these methods by cold column tests. Furthermore, we have developed the newly anion exchange resin having higher efficiency and capacity for absorbing leachables from ...

2009-10-01

89

Symbiotic star BF Cygni from 1965 to 1970  

Science.gov (United States)

Sixteen spectra of the symbiotic star BF Cygni covering the period 1965-- 1970 were investigated. Variations of the line intensities, the Balmer decrements, the color, and electronic temperatures are given. Approximate values of the electron density were deduced in order to derive an order of magnitude for the sizes of the emitting regions of BF Cygni. A crude stratification and evolution model is proposed. (auth)

1973-03-01

90

On technical opportunity of use of the pactel facility for investigation of coolant phenomenon in horizontal steam generators  

Energy Technology Data Exchange (ETDEWEB)

In this paper the possibility of using the test facility PACTEL concerning the investigations of thermal hydraulic special features of the primary coolant circuit acting under natural circulation is under consideration. It is suggested to study a stratification phenomenon of a coolant in upper plenum of a reactor and also a horizontal steam generator (HSG) hot collector temperature regime. For such investigations the facility must be modified. It is shown that this work is not large and expensive, as the facility is a lightly suitable unit for different researches. (orig.)

2001-07-01

91

On technical opportunity of use of the pactel facility for investigation of coolant phenomenon in horizontal steam generators  

International Nuclear Information System (INIS)

In this paper the possibility of using the test facility PACTEL concerning the investigations of thermal hydraulic special features of the primary coolant circuit acting under natural circulation is under consideration. It is suggested to study a stratification phenomenon of a coolant in upper plenum of a reactor and also a horizontal steam generator (HSG) hot collector temperature regime. For such investigations the facility must be modified. It is shown that this work is not large and expensive, as the facility is a lightly suitable unit for different researches. (orig.)

2001-03-20

92

Code requirements document: MODFLOW 2.1: A program for predicting moderator flow patterns  

Energy Technology Data Exchange (ETDEWEB)

Sudden changes in the temperature of flowing liquids can result in transient buoyancy forces which strongly impact the flow hydrodynamics via flow stratification. These effects have been studied for the case of potential flow of stratified liquids to line sinks, but not for moderator flow in SRS reactors. Standard codes, such as TRAC and COMMIX, do not have the capability to capture the stratification effect, due to strong numerical diffusion which smears away the hot/cold fluid interface. A related problem with standard codes is the inability to track plumes injected into the liquid flow, again due to numerical diffusion. The combined effects of buoyant stratification and plume dispersion have been identified as being important in operation of the Supplementary Safety System which injects neutron-poison ink into SRS reactors to provide safe shutdown in the event of safety rod failure. The MODFLOW code discussed here ...

1992-03-01

93

Code requirements document: MODFLOW 2. 1: A program for predicting moderator flow patterns  

Energy Technology Data Exchange (ETDEWEB)

Sudden changes in the temperature of flowing liquids can result in transient buoyancy forces which strongly impact the flow hydrodynamics via flow stratification. These effects have been studied for the case of potential flow of stratified liquids to line sinks, but not for moderator flow in SRS reactors. Standard codes, such as TRAC and COMMIX, do not have the capability to capture the stratification effect, due to strong numerical diffusion which smears away the hot/cold fluid interface. A related problem with standard codes is the inability to track plumes injected into the liquid flow, again due to numerical diffusion. The combined effects of buoyant stratification and plume dispersion have been identified as being important in operation of the Supplementary Safety System which injects neutron-poison ink into SRS reactors to provide safe shutdown in the event of safety rod failure. The MODFLOW code discussed here ...

1992-03-01

94

Joint shear strength of FRP reinforced concrete beam-column joints  

British Library Electronic Table of Contents (United Kingdom)

An assessment of the joint shear strength of exterior concrete beam-column joints reinforced internally with Glass Fibre Reinforced Polymer (GFRP) reinforcements under monotonically increasing load on beams keeping constant load on columns is carried out in this study. Totally eighteen numbers of specimens are cast and tested for different parametric conditions like beam longitudinal reinforcement ratio, concrete strength, column reinforcement ratio, joint aspect ratio and influence of the joint stirrups at the joint. Also finite element analysis is performed to simulate the behaviour of the beam-column joints under various parametric conditions. Based on this study, a modified design equation is proposed for assessing the joint shear strength of the GFRP reinforced beam-column specimens b...

2011-01-01

95

Waste management plan for Phase II of the Bear Creek Valley treatability study Oak Ridge Y-12 Plant, Oak Ridge, Tennessee  

Energy Technology Data Exchange (ETDEWEB)

This Waste Management Plant (WMP) for the Bear Creek Valley Treatability Study addresses waste management requirements for the Oak Ridge Y-12 Plant. The study is intended to produce treatment performance data required to design a treatment system for contaminated groundwater. The treatability study will consist of an evaluation of various treatment media including: continuous column tests, with up to six columns being employed to evaluate the performance of different media in the treatment of groundwater; an evaluation of the denitrifying capacity and metal uptake capacity of a wetland system; and the long-term denitrifying capacity and metal uptake capacity of algal mats. The Sampling and Analysis Plan (SAP) covers the project description, technical objectives, procedures, and planned work activities in greater detail. The Health and Safety Plan (HASP) addresses the health and safety concerns and requirements for the proposed sampling ...

1997-05-01

96

Simultaneous determination of the 10 major components of Da-Cheng-Qi decoction in dog plasma by liquid chromatography tandem mass spectrometry.  

Science.gov (United States)

A liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous determination of the 10 major components of Da-Cheng-Qi decoction (rhein, emodin, aloe-emodin, chrysophanol, rheochrysidin, naringin, naringenin, hesperidin, magnolol and honokiol) in dog plasma. Plasma samples were spiked with internal standard (ibuprofen), acidified with HCl and extracted twice by liquid-liquid extraction using ethyl acetate. Separation was performed on a YMC-Pack ODS-A C(18) column (5 microm, 150 mm x 4.6 mm) and a C(18) guard column (5 microm, 4.0 mm x 2.0 mm) with methanol-water (92:8, v/v) at a flow rate of 0.3 mL/min. The LC/MS system was operated under the multiple reaction monitoring mode using electrospray ionization in the negative ion mode. All analytes showed good linearity over a wide concentration range (r>0.99). The linear range of the calibration curves was 5000-19.53 ng/mL for rhein; ...

2009-05-21

97

Modification of ion-exchange resin composition for the removal of gadolinium from moderator system of 540 MWe PHWRs  

International Nuclear Information System (INIS)

Gadolinium removal during the first approach to criticality of TAPP-4 540 MWe reactor using mixed bed resin (strong acid cation resin and weak base anion resin) topped with strong acid cation exchange resin yielded IX column outlet pH of >6 during the first 6 h of run during which [Gd] decreased from 2.1 to 1 mg/kg. However, the main moderator system pH was between 5.0-5.5. Technical specification for pH of moderator is in the range 5.0-5.5 as long as Gd is present. This is to avoid any precipitation of Gd in the core and a pH of 5.8 or even a pH of 5.6 when carbonate is present is specified as the upper limit of the moderator system pH for this purpose. The situation of IX column outlet pH being #>=# 6 mixing with a system water having Gd results in local mixing zone pH in the range of 6- 5.4. In order to have an iso-pH regime (5-5.5) both with respect to the IX outlet as well as in the system, studies were conducted ...

2005-11-01

98

Radiological characterization of the GRR-1 pool  

International Nuclear Information System (INIS)

GRR-1 is a 5MW open pool type research reactor with MTR-type fuel elements cooled and moderated by light water with beryllium reflectors at the two opposing sides of the core. A graphite thermal neutron column is adjusted to one side of the core. Six radial horizontal beam tubes are available, of which three contain in-pile collimators for neutron scattering instruments. The reactor is currently out of operation for inspection and refurbishment purposes. The core has been dismantled and the fuel elements are stored in the used fuel storage tank. The GRR-1 inspection and refurbishment plan involves inspection and eventually replacement of the reactor's primary cooling circuit. The health physics procedures to be implemented during inspection of the main water outlet are divided in three stages: a) pool dose rate survey from pool top, b) pool drainage by decreasing water level in steps and c) inspection ...

2007-11-05

99

The Clash of Independent Wills: How Effective Is Brigade ...  

Science.gov (United States)

... surprise. During Operation Goodwood, the British attempt to break out of their bridgeheads in Normandy, aBritish column was ...

1991-01-14

101

Meteorological Measurement Guide  

Science.gov (United States)

... 2-22 Page 31. The mercury barometer operates on the principle of air pressure forcing the mercury column up an evacuated tube. ...

1992-01-01

102

Axial symmetric surface waves in tubular magneto-active plasma column  

International Nuclear Information System (INIS)

... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,

2006-09-11

103

Dynamic positive column in long-gap barrier discharges  

CERN Document Server

A simple analytical model of the barrier discharge in a long gap between opposing plane electrodes is developed. It is shown that the plasma density becomes uniform over large part of the gap in the course of the discharge development, so that one can speak of a formation of a dynamic positive column. The column completely controls the dynamics of the barrier discharge and determines such characteristics as the discharge current, discharge duration, light output, etc. Using the proposed model, all discharge parameters can be easily evaluated

2005-01-01

104

Studies about the separation of molecular species of hydrogen's isotopes by cryogenic distillation in a plant for heavy water detritiation  

Energy Technology Data Exchange (ETDEWEB)

Cryogenic distillation is the main industrial method for separating hydrogen's isotopes, because it presents the advantage of high separating factors and also the possibility of processing great quantities of gases. In the case of multicomponent mixtures the determination of transport for molecular species between the two phases is very difficult owing to the particularities of physical characteristics of each component from the mixture. The transport of molecular species is also strongly influenced by the hydrodynamics of two phases, in strong connection with the dimension of the interface between the vapor and liquid phase. The characteristics of the interface depend on the type and geometry of the separation area: plates or package. The traditional methods of analysis for exchange processes use the concept 'theoretic plate', a physical entity for which the values of concentrations for vapors and liquid that leaves the plate are in thermodynamic equilibrium ...

1998-07-01

105

Purification of radioactive decontamination liquids from NPP Paks with reactive adsorption and ion-exchange process  

International Nuclear Information System (INIS)

In nuclear power plant Paks, Hungary, alkaline oxidative (NaOH, KMnO_4, H_2O) and acidic reductive (citric- and oxalic acid, water) liquids are using for the decontamination of primary circuit equipment (main liquid circulating pumps, steam generators, pipelines etc). The above mentioned decontamination liquids are containing "1"1"0"mAg, "9"5Nb, "5"4Mn, "5"8 Co, "6"0Co, "5"1 Cr, "1"2"4 Sb radioisotopes, summarized radioactivity is between 10"3-8x10"4 kBq/dm"3 liquid. The decontamination liquid can be cleaned with reactive adsorption (active carbon) and ion-exchange process at elevated temperature (333-368 K) in multilayered columns. After purification the summarized radioactivity for "5"4Mn, "6"0Co, and "1"1"0"mAg are in the outlet liquid below 1 kBq/dm"3. Decontamination factor DF#approx =#10"3-10"4, volumetric reduction factor VRF#approx =#50-500.

1999-11-04

106

Production of "8"3Rb and development of a generator for the separation of sup(83m)Kr from "8"3Rb  

International Nuclear Information System (INIS)

"8"3Rb was produced from rubidium by a (#gamma#,2n)-reaction. The specific activity in the irradiated samples of RbCl was 0.2 to 0.3mCi"8"3Rb/gRb. For the separation of the sup(83m)Kr in the liquid phase the cation exchanger Dowex-50WX12 proved to be a suitable carrier. sup(83m)Kr was eluted by bidistilled water. The yield ranged from 85-95%, at an elution time of 3 minutes. The decontamination factor was > 10"6. The separation of sup(83m)Kr in the gaseous phase was effected by floating a "8"3Rb loaded column with an elution gas. The best results were obtained with a generator containing aluminium oxide as carrier for "8"3Rb. The yield of sup(83m)Kr was 90-100%, the decontamination factor > 10"4, the time needed for the separation 20-60 seconds. All generators proved to be very safe even after long time of use. (orig.).

107

Phosphorous adsorption and precipitation in a permeable reactive wall: Applications for wastewater disposal systems  

Energy Technology Data Exchange (ETDEWEB)

A permeable reactive mixture has been developed using low cost, readily available materials that is capable of providing effective, long-term phosphorous treatment in areas impacted by on-land wastewater disposal. The reactive mixture creates a geochemical environment suitable for P-attenuation by both adsorption and precipitation reactions. Potential benefits include significant reductions in phosphorous loading to receiving groundwater and surface water systems, and the accumulation of P-mass in a finite and accessible volume of material. The mixture may be applied as a component within surface treatment systems or in subsurface applications such as horizontal or vertical permeable reactive walls. The mixture averaged > 90% treatment efficiency over 3.6 years of continuous-flow laboratory column experiments. The mixture was further evaluated at the pilot-scale to treat municipal wastewater, and the field-scale to treat a well-characterized ...

1997-12-31

108

Mound Facility activities in chemical and physical research: July--December 1977. [Kr-Xe and Kr-Ar diffusion; Ne-Ar thermal diffusion  

Science.gov (United States)

Isotope separation of Ar, C, /sup 3/He, Kr, Ne, O, and Xe isotopes is reported. TiFeH/sub x/, TiCoH/sub x/, TiCuH/sub x/, and VH/sub x/ were studied using NMR (proton relaxation times). VD/sub x/ and VT/sub x/ were synthesized. The problem of calculating the valence state of Pu is discussed. A series solution to the plutonium (N,H) characteristic equation is suggested. Shipments of /sup 231/Pa, /sup 230/Th, and /sup 229/Th are reported. Separation and processing of /sup 234/U are also reported. Theoretical methods were developed to calculate temperature distributions as functions of water flow rate in liquid thermal diffusion columns. Diffusion coefficients were measured from 300 to 1200/sup 0/K for Kr-Xe and Kr-Ar. New thermal diffusion factors are submitted for Ne-Ar.

1978-05-01

109

Manganese removal using an aerated granular filter  

Energy Technology Data Exchange (ETDEWEB)

Experiments on manganese removal using an aerated granular filter with mean particle size of 3.68 mm and 5.21 mm anthracite were conducted at a filtration rate of 100 m d{sup -1}. Air, with a rate of 0 to 366 m d{sup -1}, was supplied through nozzles positioned 100 mm above the filter column bottom. From the experiments that were conducted, it was found that manganese removal is completed at a pH of 9.6 or above. In addition, the oxidation and removal rate of dissolved manganese were expressed as a first-order reaction. The smaller the filter media particles were, the higher the manganese removal efficiency was. The aeration rate of dissolved oxygen in raw water is sufficient for the manganese removal process. The manganese removal rate increased with time due to the catalytic effect of manganese dioxide (MnO{sub 2}) attached to the media. The x-ray diffraction analysis showed that the solids attached to the filter media were not crystalline ...

2007-09-15

110

Kinetics of absorption of trace iodine vapor in aqueous solution of sodium hydroxide, (2)  

International Nuclear Information System (INIS)

A liquid column was used for the experiments reported in Part 1. However, it only gives the observation of the effect of fast reaction because the liquid flow was controlled to uniform laminar flow and the contact is limited to short time of around 10 ms. In practical absorbing operation, turbulence is involved in liquid flow, and the residence time for contact is long. Hence, the absorption of trace iodine in the purified air has been experimented by using a constant interface area type stirred absorption tank. Prior to the experiment, the characteristics of the absorption tank was investigated by conducting pure carbon dioxide absorption test with purified water. It gave the conclusion that the tank was sufficiently usable for fundamental researches. In short contact time absorption, the iodine dissolved and absorbed in liquid phase is affected by reaction of hypoiodous acid and poly-iodide ion formation due to hydrolysis by basic catalyst, ...

1978-01-01

111

In situ studies with Asian clams (Carbacula fluminea) detect acid mine drainage and nutrient inputs in low-order streams  

International Nuclear Information System (INIS)

This study evaluates the correlation between transplanted Asiatic clam and indigenous community responses to acid mine drainage and nutrient loading in first-to-third-order streams, by comparing the toxicological endpoints of clam survival and growth with benthic macro-invertebrate community indices as community responses to both acid mine drainage and nutrient loading. Clam survival was found to be positively correlated with water column pH and negatively correlated with conductivity and metal concentrations. There was also a positive correlation with the relative abundance of the macro-invertebrate Ephemeroptera, the most sensitive taxonomic group, to acid mine drainage in this watershed. No correlation was found between clam growth and acid mine drainage inputs, but there was evidence of positive correlation with nitrate concentrations and the relative abundance of collector-filterer functional feeding groups. These results suggest that clam ...

2001-03-01

112

Flow induced vibration mock-up test for heat exchanger tubes of PWR steam generator  

International Nuclear Information System (INIS)

It is one of the most important subjects to estimate the flow-related stability of the heat exchanger tubes. A large scale model steam generator has been developed to verify the stability of the tubes in the Japanese PWR steam generators for the two-phase flow-induced vibration and to accumulate related technical data of thermal-hydraulic and flow-induced vibration of U-bend tube bundle. The model steam generator has 230 U-bend tubes of 46 different radius and 5 columns for each of practical diameter and material, and the anti vibration bars are inserted into each spacing between tube arrays. The freon R123 has been used as the secondary side fluid in stead of water-steam two-phase. In the test, void fraction and interfacial velocities in U-bend and straight tube-bundle are measured with bi-optical probes, and vibration responses of some selected tubes are measured with strain gauges and accelerators. It is verified that the U-bend tubes are ...

2000-10-01

113

Behaviour of nonlinear supports on a PWR coolant system during a postulated LOCA. Pt. 1; Effect of modelling methods  

Energy Technology Data Exchange (ETDEWEB)

A 4-loop Pressurised Water Reactor (PWR) primary coolant system has been analysed for the postulated Loss of Coolant Accident (LOCA) event in order to derive peak dynamic loads for qualifying the design of equipment supports and pipe whip restraints. Pipe whip restraints as well as pipe and equipment supports are nonlinear by nature because of the presence of gaps and the different directional stiffnesses arising from snubber, steelwork and geometric and material interaction at the concrete to steel embedment. The different structural idealisations for the supports and restraints have an influence on the dynamic response of the structure. In the first of the two part paper a range of idealisation models for the Steam Generator and Reactor Coolant Pump vertical columns ranging from elastic stiffnesses to bilinear stiffnesses with or without preload were examined. Due to both structural and loading complexity, the behaviour of these supports were ...

1993-07-01

114

Production and evaluation of labeled bisphosphonates with 153Sm, 166Ho and 177Lu as therapeutic radiopharmaceuticals  

International Nuclear Information System (INIS)

Aim: Compounds such "9"9"mTc-MDP and "9"9"mTc-HEDP are used regularly in bone scintigraphy for metastasis detection. The therapeutics properties of beta emitter radionuclides like "1"5"3Sm, "1"6"6Ho and "1"7"7Lu has been widely reported in literature being "1"7"7Lu the less developed for medical applications. With the purpose of study different radiopharmaceuticals alternatives, for metastasis bone palliation, we have evaluated, on a comparative basis, the labeling of "1"5"3Sm-MDP, "1"5"3Sm-HEDP, "1"6"6Ho-MDP, "1"6"6Ho-HEDP, "1"7"7Lu-MDP and "1"7"7Lu-HEDP from the exhibited radionuclidic purity and biological distribution point of view. Material and Methods: The radionuclides were produced at La Reina Research Reactor, Chilean Nuclear Energy Commission. The radionuclidic purity was determined by gamma-Ray spectrometry. The labeling was accomplished with MDP (Plenum) and HEDP synthesized in-house. The in-vitro affinity of labeled compounds to the mineral bone matrix was determined using ...

2002-09-01

115

Critical phenomena in four-component systems  

Science.gov (United States)

This article examines problems relating to the calculation of the position of regions of limited solubility of components in the liquid state for four-component systems. An approach based on the use of criterion of stability with respect to diffusion for obtaining equations which describe the region of stratification of the liquid phase in a four-component system is used. The authors used a ES-1020 computer to analyze the critical phenomena in Al-In-P-Sb, Al-Ga-In-P, Al-Ga-In-As, and In-Ga-As-P systems. The position of the spinode in the phase diagram of a four-component system is obtained.

1987-06-01

116

Comparison of two models of dynamic subsidence  

Energy Technology Data Exchange (ETDEWEB)

Comparatively evaluates two models for forecasting ground subsidence after underground mining: a standard method used in Poland in underground coal mining and a method used in the GDR. Factors that influence ground subsidence after underground mining are evaluated. Effects of depth, stratification, and physical and mechanical properties of rock strata are analyzed. Time dependence of dynamic troughs and static final troughs left after underground mining is evaluated. Formulae are recommended for forecasting ground subsidence after underground coal mining and mining of other deposits. 3 refs.

1988-01-01

117

Buoyancy effects in double-diffusive and mixed convection flows  

Science.gov (United States)

When induced by bottom heating in a horizontal fluid layer which is characterized by forced motion or solute stratification, buoyancy-driven flows may assume a variety of forms. The flows, which are examples of mixed or double-diffusive convection, can strongly influence heat tranfer or the entrainment of stratified fluid. General aspects of each form of convection are reviewed, and emphasis is placed on mixed convection in a horizontal rectangular channel and on double-diffusive convection due to thermally driven mixed-layer development in a solutally stratified fluids. Flow conditions are described, and experimental and theoretical results are presented for related heat-transfer and entrainment parameters.

1986-01-01

118

Seismic tests of post-tensioned self-centering building frames with column and slab restraints  

British Library Electronic Table of Contents (United Kingdom)

Post-tensioned (PT) self-centering moment frames have been developed as an alternative to typical moment-resisting frames (MRFs) for earthquake resistance. When a PT frame deforms laterally, gaps between the beams and columns open. However, the gaps are constrained by the columns and the slab in a real PT self-centering building frame. This paper presents a methodology for evaluating the column restraint and beam compression force based on the column deformation and gap openings at all stories. The method is verified by cyclic tests of a full-scale, two-bay by one-story PT frame. Moreover, a sliding slab is proposed to minimize restraints on the expansion of the PT frame. Shaking table tests were conducted on a reduced-scale, two-by-two bay one-story specimen, which comprises one PT frame ...

2011-01-01

119

Reinforced concrete beam-column joint strengthened with carbon fiber reinforced polymer  

British Library Electronic Table of Contents (United Kingdom)

An effective rehabilitation strategy is proposed to enhance the strength and stiffness of the beam-column joint in this study. An analytical model is proposed to predict the column shear of the joints strengthened with carbon fiber reinforced polymer (CFRP). Three full scale interior beam-column joints, including two specimens strengthened with CFRP and one prototype specimen, are tested in this study. The specimens are designed to represent the pre-seismic code design construction in which there is no transverse reinforcement. A new optical non-contact technique, digital image correlation (DIC), which can measure the full strain field of specimen, is used to measure and observe the full strain field of the joint. The experimental results show that the beam-column joints strengthened with ...

2010-01-01

120

Testing of CoTreat Inorganic Ion Exchange Media for the Removal of 60Co from Thorp Pond Water  

Energy Technology Data Exchange (ETDEWEB)

CoTreat, a new inorganic ion exchange media, has been studied in the laboratory to support its application as a pre- coat to existing Funda filters in THORP feed pond plant (Sellafield, UK). This is a novel way of application of CoTreat, which is usually utilized in fixed-bed ion exchange columns in a granular form. The results present the effect of operating conditions (CoTreat dose, pond water chemistry) on CoTreat performance for the removal of Co-57 tracer from simulated pond water. Major findings include the strong dependence of Co-57 decontamination factor (DF) on feed activity. At the 200 Bq/L feed level, the observed DF was 10-20 but rose to 1000 and above when the feed level was increased to 20000 Bq/L. Calcium present in the feed was found to decrease the DF at concentrations higher than 1 ppm. The laboratory studies showed significantly higher DF's than what has been observed in large-scale THORP tests. ...

2003-02-25

121

Influence of Hexagenia on the fate and bioavailability of contaminants in sediment  

International Nuclear Information System (INIS)

The influence of sediment dwelling macroinvertebrates on fate and bioavailability of contaminants in freshwater systems was determined using the burrowing mayfly, Hexagenia limbata, as a representative benthic organism. Two series of experiments were conducted: the first to determine the effect of mayflies on movement of contaminants into sediment and organisms, and the second to examine the effect of mayflies on release of contaminants from sediments to the water column and their subsequent accumulation in fish. Concentrations of "1"4C labelled DDT, hexachlorobenzene (HCB), and dihexylphthalate (DHP) in water were 0.11 +/- 0.01, 0.062 +/- 0.005 and 0.006 +/- 0.007 ppb, respectively. Total mass of DHP in the burrow wall was about equal to mass on the surface, indicating that mayflies were capable of doubling the amount of DHP sorbed per unit surface area of sediment. Adsorption of contaminants from ...

122

Final phase testing and evaluation of the 500 kW direct contact pilot plant at East Mesa  

Energy Technology Data Exchange (ETDEWEB)

The testing performed during the last phase of the geothermal direct contact heat exchanger program utilizing the 500 kW pilot plant provided more insight into the capabilities and limits of the direct contact approach and showed that more work needs to be done to understand the inner workings of a large direct contact heat exchanger if they are to be modeled analytically. Testing of the column demonstrated that the performance was excellent and that the sizing criteria is conservative. The system operated smoothly and was readily controlled over a wide range of operating conditions. Performance evaluation showed pinch differentials of 4/sup 0/F or less and better than predicted heat transfer capability. Testing during this final phase was directed towards establishing the limits of the column to transfer heat. The working column height was shortened progressively to approximately 16 feet from a design length of 28 feet. ...

1983-12-01

123

Modelling the reworking effects of bioturbation on the incorporation of radionuclides into the sediment column: implications for the fate of particle-reactive radionuclides in Irish Sea sediments  

Energy Technology Data Exchange (ETDEWEB)

A microcosm laboratory experiment was conducted to determine the impact of biological reworking by the ragworm Nereis diversicolor on the redistribution of particle-bound radionuclides deposited at the sediment-water interface. Over the course of the 40-day experiment, as much as 35% of a {sup 137}Cs-labelled particulate tracer deposited on the sediment surface was redistributed to depths of up to 11 cm by the polychaete. Three different reworking models were employed to model the profiles and quantify the biodiffusion and biotransport coefficients: a gallery-diffuser model, a continuous sub-surface egestion model and a biodiffusion model. Although the biodiffusion coefficients obtained for each model were quite similar, the continuous sub-surface egestion model provided the best fit to the data. The average biodiffusion coefficient, at 1.8 {+-} 0.9 cm{sup 2} y{sup -1}, is in good agreement with the values quoted by other workers on the bioturbation effects of this ...

2010-11-15

124

Modelling the reworking effects of bioturbation on the incorporation of radionuclides into the sediment column: implications for the fate of particle-reactive radionuclides in Irish Sea sediments  

International Nuclear Information System (INIS)

A microcosm laboratory experiment was conducted to determine the impact of biological reworking by the ragworm Nereis diversicolor on the redistribution of particle-bound radionuclides deposited at the sediment-water interface. Over the course of the 40-day experiment, as much as 35% of a "1"3"7Cs-labelled particulate tracer deposited on the sediment surface was redistributed to depths of up to 11 cm by the polychaete. Three different reworking models were employed to model the profiles and quantify the biodiffusion and biotransport coefficients: a gallery-diffuser model, a continuous sub-surface egestion model and a biodiffusion model. Although the biodiffusion coefficients obtained for each model were quite similar, the continuous sub-surface egestion model provided the best fit to the data. The average biodiffusion coefficient, at 1.8 #+-# 0.9 cm"2 y"-"1, is in good agreement with the values quoted by other workers on the bioturbation effects of this polychaete ...

2010-11-01

125

Natural gas in Lake Erie: a reconnaissance survey of discharges from an offshore drilling rig  

Energy Technology Data Exchange (ETDEWEB)

Field studies were conducted May 28-June 1, 1979, to determine the chemical composition and physical behavior of discharges from an offshore gas drilling rig in the central basin of Lake Erie. The drilling operation was observed for four days, from rig jackup to the circulation of mud through the borehole after drilling had been completed. Resuspension studies using nephelometry, supplemented with chemical analyses, indicated little resuspension of lake bottom materials or release of metals to the water column during rig jack-up. Portions of the turbidity plumes generated during drilling were buoyant. Three surface turbidity plumes were mapped with nephelometry to a point at which particulate concentrations reached background levels in the Lake. Detectable plumes were approx. 400 to 1500 m in length and had maximum widths < 230 m. A chemical survey conducted in the plume during early gas shows indicated that discharged inorganic chemical ...

1980-10-01

126

Development of the ELEX process for tritium separation at reprocessing plants  

International Nuclear Information System (INIS)

The ELEX process for isotopic enrichment and separation of tritium from aqueous reprocessing effluents is described. After the development of an appropriate hydrophobic catalyst and the study of the separate constituent steps of the ELEX process, an integrated bench-scale installation with a detritiation capacity of 10 mol water per hour was constructed. It comprises essentially a 1.5 kW electrolyser and two 2 cm diameter by 3 m high exchange columns. In this mini-pilot the ELEX process was successfully demonstrated by detritiating more than 1000 dm"3 water containing up to 100 mCi tritium per dm"3, which is the feed concentration expected for application of the process in a reprocessing plant. The process decontamination factor was always larger than 100 and the overall tritium balance could be kept within the experimental errors of the various measurements. Depending on the duration of the runs, the volume reduction ...

1985-03-01

127

Performance of the gas bubble column in molten salt systems  

Energy Technology Data Exchange (ETDEWEB)

Experimental data on the gas holdup and the mean bubble size in a bubble column with a single nozzle was obtained for gas-molten salt systems of a eutectic mixture of LiCl (58 mol %)-KCl (42 mol %) and molten NaNO/sub 3/. The liquid-phase mass transfer coefficient K /SUB L/ was evaluated from the specific surface area a and the volumetric coefficient K /SUB L/ a data for oxygen and carbon dioxide absorption into molten NaNO/sub 3/. The dimensionless correlations of the performance of bubble columns for aqueous solutions can be extended to the gas-molten salt systems.

1984-01-01

128

The Place of Ethics in Ireland and Elsewhere  

British Library Electronic Table of Contents (United Kingdom)

Abstract: [public affairs, ethical currents, Ireland, social research ethics] Liam Frink is contributing editor of Ethical Currents, the AN column of the AAA Committee on Ethics.

2011-01-01

129

Spatial and Temporal Variability of Column Integrated Aerosol - NASA  

Science.gov (United States)

the southern Arabian Gulf region left its signature on the heterogeneous aerosol .... Arabian Gulf region, since large differences in ? may be caused by ...

130

Separation of oligo-RNA by reverse-phase HPLC.  

UK PubMed Central (United Kingdom)

A rapid and highly reproducible chromatographic technique has been developed for analysis and purification of complex mixtures of oligoribonucleotides. The method utilizes a column of microparticulate...Full Text Available

1979-10-25

131

National Advisory Committee for Aeronautics 1952 - NASA Technical ...  

Science.gov (United States)

By Charles E. Watkins. 2458. An Instrument Employing a Coronal Discharge for ..... Grover, W. S. Hyler, and L. R. Jackson. 2640. Interaction of Column and ...

132

Design and mass transfer characteristics of rotating screw brush horizontal distillation column  

Energy Technology Data Exchange (ETDEWEB)

A distillation column with an adjustable slope horizontal rectification section was constructed. A rotating screw brush was inserted into the section, which could be rotated from 0 to 600 rpm with an external motor. Distillation experiments were carried out using the system cyclohexane-heptane at total reflux at slopes of 0(horizontal), 5 and 10 degrees. Separation efficiency for the horizontal column was the highest of the three orientations, and was obtained as HETP from 0.04 to 0.16 m at F-factor of 0.05 to 0.4 m/s(kg/m{sup 3}){sup 1/2} in the range of 100 to 600 rpm. The HETP for each slope was roughly constant at a rotation speed of more than 300 rpm. The values of the pressure drop were found to be equivalent to those of one seventh to one fifth of conventional packed columns. (author)

2000-10-01

133

Chitosan-silica hybrid-coated open tubular column for hydrophilic interaction capillary electrochromatography  

British Library Electronic Table of Contents (United Kingdom)

Abstract A novel and convenient protocol for the preparation of an open-tubular column coated with chitosan-silica hybrid using chitosan and silane-coupling agent (-glycidoxy-propyltrimethoxysilane) was developed for CEC, in which, chitosan was covalently bonded to the inner wall of a fused-silica capillary using -glycidoxy-propyltrimethoxysilane as a cross-linking agent. The stationary phase was hydrophilic due to the chitosan-silica hybrid with abundant amine and hydroxyl functional groups. The chromatographic characteristics of the column were evaluated by the separation of some organic acids and inorganic anions. The column showed good selectivity for nucleotides, aromatic acids, and inorganic anions. The mechanism for the separation of these compounds was primarily based on the hydrop...

2011-01-01

134

Buckling analysis of structural steel frames with inelastic effects according to codes  

British Library Electronic Table of Contents (United Kingdom)

Steel building frames are often analyzed for stability in an elastic way, while most of their columns behave inelastically at the buckling stage. Most column design provisions allow for inelastic behavior, but overall inelastic stability analysis is rarely performed. In this study the analysis philosophy is centered on the overall frame stability and its true safety factor. As many columns show inelastic behavior at the buckling stage, the proposed procedure takes due consideration of this fact. Once the overall buckling factor for the frame is obtained, individual column effective length factors, and their true slenderness ratios are computed, and used in the design relationships. This procedure circumvents the use of design nomographs and numerous formulas proposed in the past to allevia...

2009-01-01

135

Advanced 3D Visualization Web Technology and its Use in ...  

Science.gov (United States)

... applications related to military and intelligence area ... the technology solved yet, but the open issue still ... fields, columns; ie data source, document type ...

2002-04-01

136

MENTOR-BASED EFFORT TO ADVANCE IMPLEMENTATION OF PREFERRED MANAGEMENT PRACTICES (PMPS) FOR OIL PRODUCERS IN SOUTH MIDCONTINENT (OKLAHOMA/ARKANSAS) AND WEST COAST (CALIFORNIA) REGIONS  

Energy Technology Data Exchange (ETDEWEB)

The Petroleum Technology Transfer Council (PTTC) and cooperating Regional Lead Organizations (RLOs) in its South Midcontinent (Oklahoma Geological Survey, Norman, Oklahoma) and West Coast (University of Southern California, Los Angeles, California) regions conducted a ''Mentor-Based Effort to Advance Implementation of Preferred Management Practices (PMPs) For Oil Producers'' (DE-FC26-01BC15272) under an award in Phase I of Department of Energy's (DOE's) PUMP (Preferred Upstream Management Practices) program. The project's objective was to enable producers in California, Oklahoma and Arkansas to increase oil production, moderating or potentially reversing production declines and extending the life of marginal wells in the near term. PTTC identified the primary constraints inhibiting oil production through surveys and PUMPer direct contacts in both regions. The leading common constraint was excess produced ...

2004-12-01

137

Pit Lake modelling phase 2 task A : validation and refinement of existing RMA10 and DYRESM Pit Lake hydrodynamic results[End Pit Lake phase 2 modelling  

Energy Technology Data Exchange (ETDEWEB)

This interim technical report presented a summary of results obtained from Pit Lake models developed from different simulation models. The models were used to predict stratification in a hypothetical Pit Lake. Predictions were used to assess the hydrodynamic similarities and differences between the 2 models and to determine if the models would produce similar stratification profiles for the Pit Lakes to previous models. Results showed that the models produced similar results for both temperatures and salinities. The main difference between the RMA10 and CE-QUAL-W2 model used in a previous study was found to be run time. A sensitivity analysis of the RMA10 and CE-QUAL-W2 model predictions was completed to assess the effects of segmentation; time step; lake surface area; lake orientation; and model coefficients or parameters. Results showed that the selected time step and model segmentation were appropriate, as both led to modelling results that ...

2006-06-15

138

Quasi-stationary and transient patterns in jets  

Science.gov (United States)

Apparent evolution of relativistic flows as traced by radio emission results from a combination of several factors related to propagation of relativistic blobs or shocks, velocity, density and pressure stratification of the underlying flow, plasma instability and (possibly also) phase and time travel effect. This combination can create an intricate and chaotic patterns of the observed morphological changes in radio emission, which complicates the analysis and interpretation of kinematic and physical properties of the jet plasma. Recent studies have indicated that slow and quasi-stationary patterns in jets are most likely formed by plasma instabilities while faster, superluminally moving patterns are related to highly relativistic plasma condensations produced by the nuclear flares. Some of the stationary patterns may also be related to recollimation shocks or locations where strong non-thermal continuum is produced in jets. Similarities and differences of the AGN ...

2011-01-01

139

Prognostic value of plasma B-type natriuretic peptide in patients with severe cardiotoxic drug poisoning  

British Library Electronic Table of Contents (United Kingdom)

Background/Objectives: Cardiotoxic drug poisoning can lead to severe cardiac shock (CS) and death. B-type natriuretic peptide (BNP) is a well-established diagnostic and prognostic marker in heart failure but has never been assessed in patients with cardiotoxic drug poisoning. The aim of the study was to determine whether BNP could be useful for early stratification of patients admitted to intensive care unit. Methods: 30 consecutive patients experiencing shock and cardiotoxic drug exposure were enrolled in a prospective monocentric study and underwent at least two BNP measurements within the first 24 h after admission. Results: While BNP values on admission were poorly informative, subsequent BNP measurements (11 +- 6 h after admission) were significantly increased in patients with CS comp...

2011-01-01

140

On the evolution of supernova remnants: Pt. 2  

International Nuclear Information System (INIS)

Supernova explosions within wind-driven bubbles are studied with 2D hydrodynamical calculations. Two different density distributions for the ejecta are considered: (i) a smooth, unfragmented power-law stratification, and (ii) a fragmented distribution. As in 1D models, the presence of the shell of interstellar swept-up matter causes the rapid evolution of the remnant to the radiative phase. The main 2D effects, for both fragmented and unfragmented ejecta, include: (i) substantial chaotic deviations from a purely radial flow in the remnant interior, (ii) efficient turbulent mixing between the ejecta and the shocked wind, resulting in homogenization of the former wind cavity, and (iii) severe distortion of the wind-driven shell by cooling and Rayleigh-Taylor instabilities. (author).

141

Investigation of mixed convection in a large rectangular enclosure  

Energy Technology Data Exchange (ETDEWEB)

This experimental research investigates mixed convection and heat transfer augmentation by gaseous forced jets in a large enclosure, at conditions simulating those of passive containment cooling systems for Gen III+ passively safe reactors. The experiment is designed to measure the key parameters governing heat transfer augmentation by forced jets, and to investigate the effects of geometric factors, including the jet diameter, jet injection orientation, interior structures, and enclosure aspect ratio. The tests cover a variety of injection modes leading to flow configurations of interest for mixing and stratification phenomena in containments under accident conditions. Correlations for heat transfer augmentation by forced jets are developed and compared with experimental data. The characteristic recirculation speed inside the enclosure is introduced and analyzed. Steady stratified temperature distributions are compared with model simulations of the BMIX++ code.

2007-05-15

142

Investigation of mixed convection in a large rectangular enclosure  

International Nuclear Information System (INIS)

This experimental research investigates mixed convection and heat transfer augmentation by gaseous forced jets in a large enclosure, at conditions simulating those of passive containment cooling systems for Gen III+ passively safe reactors. The experiment is designed to measure the key parameters governing heat transfer augmentation by forced jets, and to investigate the effects of geometric factors, including the jet diameter, jet injection orientation, interior structures, and enclosure aspect ratio. The tests cover a variety of injection modes leading to flow configurations of interest for mixing and stratification phenomena in containments under accident conditions. Correlations for heat transfer augmentation by forced jets are developed and compared with experimental data. The characteristic recirculation speed inside the enclosure is introduced and analyzed. Steady stratified temperature distributions are compared with model simulations of the BMIX++ code.

2007-05-01

143

Separation of isomers of saturated polycyclic hydrocarbons in packed capillary columns with graphitized thermal carbon black  

Energy Technology Data Exchange (ETDEWEB)

Using the example of perhydrophenanthrene, perhydroanthracene and cyclopentanodecalin isomers a possibility is shown to use packed capillary columns containing graphitized thermal carbon black for a complete separation of high-boiling mixtures of polycyclic saturated hydrocarbon isomers in accordance with the geometric structure of their molecules.

1981-03-01

144

Measurement of the fast neutron component in the beam of the NPL Thermal Neutron Column using a Bonner sphere spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)

1999-05-01

145

Measurement of the fast neutron component in the beam of the NPL Thermal Neutron Column using a Bonner sphere spectrometer  

International Nuclear Information System (INIS)

Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)

146

Interphase mass transfer in the separation of isotopes in countercurrent columns (liquid-solid systems)  

International Nuclear Information System (INIS)

The results of calculated and experimental investigation of interphase isotopic exchange efficiency in countercurrent columns are given when separation processes of isotope mixtures are taken place with use of liquid-solid systems. Effect of liquid phase flow on transfer unit height in ion exchange separation of boron, lithium, nitrogen isotopes is considered. 40 refs.; 5 figs.

147

De-entrainment of boron by evaporation  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this research was to investigate the de-entrainment of boron for evaporators used in nuclear power plants. The forced circulation and semi-continuous type evaporator was used in the experiment. Cyclone and glass-wool packed column which is supposed to provide good decontamination factor as well as easy maintenance, were selected as de-entrainment device to be used in the evaporation of radioactive liquid wastes. The de-entrainment device combined with cyclone and glass-wool column has shown overall DF more than 1000 for boron.

1986-12-01

148

An Explanation for Positive Differential dc Voltage-Current Characteristics in Weakly Ionized, Low-Pressure Positive Column Gas Discharge Plasmas  

Energy Technology Data Exchange (ETDEWEB)

A physical explanation is given for the positive differential voltage-current characteristic seen at low current in weakly ionized, low-pressure positive column discharges in argon/mercury gas mixtures. {copyright} {ital 1996 The American Physical Society.}

1996-07-01

149

Vacuum ultraviolet radiometry of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two quantities are combined to yield the radiant ...

1995-10-01

150

Simultaneous biosorption of chromium(VI) and copper(II) on Rhizopus arrhizus in packed column reactor: Application of the competitive Freundlich model  

Energy Technology Data Exchange (ETDEWEB)

The simultaneous biosorption of Cr(VI) and Cu(II) on free Rhizopus arrhizus in a packed column operated in the continuous mode was investigated and compared to the single metal ion situation. The breakthrough curves were measured as a function of feed flow rate, feed pH, and different combinations of metal ion concentrations in the feed solutions. Column competitive biosorption data were evaluated in terms of the maximum (equilibrium) capacity in the column, the amount of metal loading on the R. arrhizus surface, the adsorption yield, and the total adsorption yield. In the single-ion situation the adsorption isotherms were developed for optimum conditions, and it was seen that the adsorption equilibrium data fit the noncompetitive Freundlich model. For the multicomponent adsorption equilibrium the competitive adsorption isotherms were also developed. The competitive Freundlich model for binary metal mixtures represented ...

1999-12-01

151

Preparation of a "6"2Zn-"6"2Cu generator and of "6"1Cu following alpha particle irradiation of a nickel target  

International Nuclear Information System (INIS)

The "6"2Zn-"6"2Cu generator system is one of the few which yield a pure positron emitting daughter. The authors have developed a method for the preparation of this generator system following 32 MeV #alpha# particle bombardment of nickel targets. The chemical processing involves two stages: first a hydrous zirconium oxide column is used at pH 4-5 to separate the zinc and copper activities produced in the target nickel, and secondly, a conventional anion exchange column is used to retain the "6"2Zn and remove all copper activities in 2M HCl. This column serves as the "6"2Cu generator which will yield pure "6"2Cu repeatedly, free from "6"2Zn and other impurities, in a mixture of HCl and NaCl. A method is outlined also to obtain a solution of "6"2Zn using the hydrous zirconium oxide (HZO) column. "6"1Cu can be prepared as a by-product in the above procedure, but a method for the preparation of "6"1Cu alone ...

152

Amount of confining reinforcement required for flexural ductility of reinforced concrete columns. Tekkin concrete chu buzai no mage jinsei to yokokosoku (confined) hokyo kinryo  

Energy Technology Data Exchange (ETDEWEB)

In this paper, an amount of confining reinforcement required for the sufficient flexural ductility of reinforced concrete column was investigated. An equation to calculate the required confining reinforcement ratio was deduced from the analytical investigation and examination on the previous experimental data as to the effects of various factors on the required confining reinforcement ratio. The rotation angle required in plastic hinges, the axial force ratio, the material properties such as concrete strength, and the ratio of core area to the whole area of column sections were employed as the factors. From the examination of the equation, it was shown that the ultimate rotation in plastic hinges calculated by the equation was more conservative than the ultimate rotaion angle of members obtained by test column specimens. It was also indicated that the ultimate rotation angle of members of columns failed ...

1991-09-15

153

Terra Nova Environmental effects monitoring program  

Energy Technology Data Exchange (ETDEWEB)

Elements of the environmental effects monitoring program in the Terra Nova oil field, about 350 km east-southeast of St. John's, Newfoundland, are described. This oilfield is being developed using a floating production storage and offloading (FPSO) facility. A total of 24 wells are expected to be drilled through seven subsea templates located in four glory holes to protect them from icebergs. Subsea installations will be linked to the FPSO by trenched flowlines connected to flexible risers. The FPSO will offload to shuttle tankers. First oil is expected in 2001. The environmental effects monitoring program will be conducted annually for the first two years beginning in 2000. Subsequent scheduling will be determined after a review of monitoring data collected during the first three years. Input to the design of the monitoring program was provided by all stakeholders, i. e. owners, local public, government agencies and regional and international experts. A model was developed ...

2000-07-01

154

Performance assessment for the disposal of low-level waste in the 200 east area burial grounds  

Energy Technology Data Exchange (ETDEWEB)

A performance assessment analysis was completed for the 200 East Area Low-Level Burial Grounds (LLBG) to satisfy compliance requirements in DOE Order 5820.2A. In the analysis, scenarios of radionuclide release from the 200 East Area Low-Level waste facility was evaluated. The analysis focused on two primary scenarios leading to exposure. The first was inadvertent intrusion. In this scenario, it was assumed that institutional control of the site and knowledge of the disposal facility has been lost. Waste is subsequently exhumed and dose from exposure is received. The second scenario was groundwater contamination.In this scenario, radionuclides are leached from the waste by infiltrating precipitation and transported through the soil column to the underlying unconfined aquifer. The contaminated water is pumped from a well 100 m downstream and consumed,causing dose. Estimates of potential contamination of the surrounding environment were developed ...

1996-08-15

155

Nitrogen utilization during spring phytoplankton bloom development in the southeast Bering Sea  

Energy Technology Data Exchange (ETDEWEB)

Interactions beween a high latitude, continental shelf, spring phytoplankton bloom and water column physics and chemistry were studied using /sup 15/N measured rates of nitrogen uptake. Peak bloom conditions commenced when the mixed layer shallowed and minimized respirational losses. Integrative light-mixing growth models were accurate during early bloom stages. An advection-diffusion model associated peak bloom nitrate uptake with pycnocline mixing rates of 2.1 m d/sup -1/ in an 18 m mixed layer. Maximum nitrogen specific uptake rates (hr/sup -1/), unlike those of carbon, coincided with peak bloom conditions. Although species compositions among peak bloom periods were similar, particulate C/N ratios were not. Apparently, both intercellular factors and prevailing mixing conditions influence specific uptake rates and cell composition. A large proportion of new (nitrate) to total productivity was associated with the dominance of the early bloom ...

1983-01-01

156

Ion-exchange scheme for selective removal of gadolinium nitrate from the moderator system of 540 MWe Indian PHWRs using macroporous strong acid cation and macro porous weak base anion resins  

International Nuclear Information System (INIS)

Gadolinium nitrate has been employed in Indian nuclear reactors for the first time as soluble neutron poison in the heavy water moderators of the 540 MWe PHWRs TAPS 3 and 4, as a fast acting secondary shut down system (SDS-2); and also for reactivity shim. For this purpose, the moderator purification system is currently equipped with special ion-exchange columns/schemes, developed by present authors. However, for gadolinium removal from moderator in the post SDS-2 scenario, the two stage ion-exchange - cation bed operation followed by mixed bed operation - results in low pH conditions persisting in the moderator for a few hours, which gives rise to certain operational problems. The present paper describes a mixed bed ion-exchange scheme employing macro-porous strong acid cation and macro-porous weak base anion resins, which has been developed to eliminate acidic conditions and gives a better pH control. The cation to anion capacity ratio in the ...

2008-12-01

157

Global changes and the air-sea exchange of chemicals  

International Nuclear Information System (INIS)

Present and potential future changes to the global environment have important implications for marine pollution and for the air-sea exchange of both anthropogenic and natural substances. This report addresses three issues related to the potential impact of global change on the air-sea exchange of chemicals: Global change and the air-sea transfer of the nutrients nitrogen and iron. Global change and the air-sea exchange of gases. Oceanic responses to radiative and oxidative changes in the atmosphere. The deposition of atmospheric anthropogenic nitrogen has probably increased biological productivity in coastal regions along many continental margins. Atmospheric deposition of new nitrogen may also have increased productivity somewhat in mid-ocean regions. The projected future increases of nitrogen oxide emissions from Asia, Africa and South America will provide significant increases in the rate of deposition of oxidized nitrogen to the central North Pacific, the equatorial Atlantic, and ...

1996-08-01

158

Carbon dioxide absorption with aqueous potassium carbonate promoted by piperazine  

Energy Technology Data Exchange (ETDEWEB)

This paper presents thermodynamic and kinetic data collected for aqueous blends of piperazine (PZ), an ethylamine, and potassium carbonate (K{sub 2}CO{sub 3}). Mixtures of K{sup +} and PZ have been investigated in a wetted-wall column at 40 to 80{sup o}C, typical conditions for an industrial absorber. The addition of 0.6 m PZ to 20 wt% (3.6 m) K{sub 2}CO{sub 3} increases the rate of CO{sub 2} absorption by a factor of ten from the value in unpromoted solutions at 60{sup o}C. The addition of PZ increases the heat of absorption from 4 kcal/mol in 3.6 m K{sup +} to 10 kcal/mol when 0.6 m PZ is added. The capacity, ranging from 0.4 to 0.7 mol-CO{sub 2}/kg-H{sub 2}O, approaches that of monoethanolamine (MEA) solutions and seems to be a strong function of K{sup +} concentration. Speciation of the solution was obtained using proton nuclear magnetic reasonance (NMR), verifying and quantifying the presence of three PZ species. An equilibrium model and a rate model were ...

2003-07-01

159

Altered lauric acid metabolism in renal microsomes from spontaneously hypertensive rats (SHR)  

International Nuclear Information System (INIS)

Studies investigated whether changes in omega- and (omega-1)-hydroxylation (OH) of lauric acid (LA) occurred in renal microsomes prepared from SHR compared to Wistar-Kyoto (WK) control rats. Systolic blood pressure in age-matched adult SHR and WKR were 189 +/- 3 and 123 +/- 4 mm Hg(anti X +/- SE) respectively (p < 0.001). No significant differences between SHR and WKR were seen in body weight, kidney weight or renal microsomal protein content. Renal microsomes, prepared from whole kidneys, were incubated with 10 mM NADPH and ["1"4C]LA at concentrations between 5-50 #mu#M. The 11- and 12-OH metabolites of LA were separated by HPLC using a reverse phase column with a methanol:water:acetic acid (62:37.8:0.2) mobile phase. Apparent (app) V/sub max/ values for 12-OH in WKR and SHR were 0.87 +/- 0.19 vs 1.48 +/- .11 nmoles/mg protein/min (p < 0.05), respectively, while values for 11-OH were 0.51 +/- 0.12 vs 0.60 +/- .07, respectively. No ...

1986-04-13

160

A model for estimating the hydraulic conductivity of granular material based on grain shape, grain size, and porosity  

Energy Technology Data Exchange (ETDEWEB)

Particle shape is an important parameter in numerous civil, environmental, and petroleum engineering applications. In ground-water flow, the shape of individual particles comprising the soil affects the soil`s pore size distribution and, hence, the important flow characteristics such as hydraulic conductivity and headloss. A model for delineating the relative importance of particle size, particle shape, and porosity, (and their interactions), in explaining the variability of hydraulic conductivity of a granular porous medium is developed and tested. Three types of porous media are considered in this work: spherical glass beads; granular sand; and irregularly shaped, shredded glass particles. A reliable method for quantifying the three-dimensional shape and packing of large samples of irregular particles based on their angle of repose is presented. The results of column experiments indicate that in the size range examined (i.e., 149 {micro}m to ...

1995-11-01

161

Water Quality and 401 Certification | Clean Water Act | US EPA  

Science.gov (United States)

Clean Water Act You are here: Water Laws & Regulations Policy & Guidance Clean Water Act Water Quality and 401 Certification Water Quality and 401 Certification Water Quality...

2011-08-28

162

Experimental Investigation of Fuel-Reactivity Controlled Compression Ignition (RCCI) Combustion Mode in a Multi-Cylinder, Light-Duty Diesel Engine  

Energy Technology Data Exchange (ETDEWEB)

An experimental study was performed to provide the combustion and emission characteristics resulting from fuel-reactivity controlled compression ignition (RCCI) combustion mode utilizing dual-fuel approach in a light-duty, multi-cylinder diesel engine. In-cylinder fuel blending using port fuel injection of gasoline before intake valve opening (IVO) and early-cycle, direct injection of diesel fuel was used as the charge preparation and fuel blending strategy. In order to achieve the desired auto-ignition quality through the stratification of the fuel-air equivalence ratio ( ), blends of commercially available gasoline and diesel fuel were used. Engine experiments were performed at an engine speed of 2300rpm and an engine load of 4.3bar brake mean effective pressure (BMEP). It was found that significant reduction in both nitrogen oxide (NOx) and particulate matter (PM) was realized successfully through the RCCI combustion mode even without applying exhaust gas ...

2011-03-01

163

The isolation of "1"3"9Ce after production by a proton-induced nuclear reaction on praseodymium  

International Nuclear Information System (INIS)

A method, based on anion exchange chromatography, is presented for the isolation of "1"3"9Ce after production by a proton-induced nuclear reaction on a thick praseodymium target. After bombardment the target is dissolved in nitric acid and "1"3"9Ce oxidised to the Ce(IV) oxidation state with bromic acid. "1"3"9Ce is then separated form the praseodymium by anion exchange chromatography on a Ag MP-1 resin column in a nitric acid - bromic acid mixture. "1"3"9Ce is sorbed onto the resin column and praseodymium eluted with the acid mixture. The bromic acid is washed out of the column with nitric acid and "1"3"9Ce finally eluted with dilute nitric acid containing sulphur dioxide.

2001-02-17

164

Separation of /sup 203/Pb by ion-exchange chromatography on Chelex 100 after production of /sup 203/Pb by the Pb(p,xn)/sup 203/Bi/sup EC. beta. +/ -> /sup 203/Pb nuclear reaction  

Energy Technology Data Exchange (ETDEWEB)

Bismuth radioisotopes, produced by 50-MeV proton bombardment of a lead target in a cyclotron, are separated from the lead target material by ion-exchange chromatography on a column containing 5.0 ml of Chelex 100. After a decay period of 24 hr, the /sup 203/Pb formed in situ is eluted from the column and then separated from /sup 200/Tl and /sup 201/Tl on a second ion-exchange column containing 0.5 ml of Chelex 100. Separations are sharp and carrier-free /sup 203/Pb is obtained.

1989-04-01

165

Seismic retrofitting of nonductile beam-column sub-assemblage using FRP wrapping and steel plate jacketing  

British Library Electronic Table of Contents (United Kingdom)

The paper discusses the aspects of repair and retrofitting technique adopted for a damaged reinforced concrete beam-column joint specimen under cyclic loading. A specimen designed based on Indian Standard specifications with consideration of seismic load but without adopting ductile detailing (NonDuctile) was investigated under reverse cyclic loading. Then, the damaged nonductile specimen was repaired with epoxy mortar and grouted using low viscous polymer, and retrofitted using fiber reinforced plastic (FRP) wrapping in beam and column components and steel plate jacketing in joint region. The experimental results showed that the retrofitted specimen not only regained its original strength and stiffness but also has overcome the deficiencies of nonductile detailing. The present study shows...

2011-01-01

166

Retention of pesticides in soil columns modified in situ and ex situ with a cationic surfactant  

British Library Electronic Table of Contents (United Kingdom)

A study of the effect of a clayey soil modified in situ and ex situ with the cationic surfactant octadecyltrimethylammonium bromide (ODTMA), on the retention of linuron, atrazine and metalaxyl was carried out. Leaching of these compounds was studied in columns of a natural clayey soil and the same clayey soil modified by direct injection of the surfactant in situ, and in columns of a natural sandy soil and the same sandy soil modified by intercalation of a barrier of the clayey soil saturated ex situ with the surfactant. Breakthrough curves indicated the total immobilization of linuron in modified soils and a decrease in the leaching kinetics of atrazine and metalaxyl compared to what was obtained in the natural soil. The results indicate the use of the clayey soil modified in situ or ex s...

2007-01-01

167

Mechanism of the electric field effect on the intensity of visible continuum emission from the positive column of gas discharge in a cesium vapor-xenon mixture  

British Library Electronic Table of Contents (United Kingdom)

We have studied the nature of continuum emitted in the visible spectral range from a noncontracted positive column of discharge in a cesium vapor-xenon mixture at a pressure of 45 Torr and at a degree of ionization below 3 ? 10?6. The main contribution to the continuous emission under such conditions is due to electron-xenon atom bremsstrahlung. The intensity of emission has been experimentally and theoretically studied as a function of the electric field strength and electron density in the positive column. It is established that an increase in the visible emission intensity with the electric field strength is related to an increase in the number of hot electrons in plasma.

2007-01-01

168

MODELING AN ION EXCHANGE PROCESS FOR CESIUM REMOVAL FROM ALKALINE RADIOACTIVE WASTE SOLUTIONS  

Energy Technology Data Exchange (ETDEWEB)

The performance of spherical Resorcinol-Formaldehyde ion-exchange resin for the removal of cesium from alkaline radioactive waste solutions has been investigated through computer modeling. Cesium adsorption isotherms were obtained by fitting experimental data using a thermodynamic framework. Results show that ion-exchange is an efficient method for cesium removal from highly alkaline radioactive waste solutions. On average, two 1300 liter columns operating in series are able to treat 690,000 liters of waste with an initial cesium concentration of 0.09 mM in 11 days achieving a decontamination factor of over 50,000. The study also tested the sensitivity of ion-exchange column performance to variations in flow rate, temperature and column dimensions. Modeling results can be used to optimize design of the ion exchange system.

2008-08-26

169

Experimental Investigation on the Seismic Performance of Beam-Column Joints Reinforced with GFRP Bars  

British Library Electronic Table of Contents (United Kingdom)

Glass fiber-reinforced polymer (GFRP) reinforcing bars were used recently as main reinforcement for concrete structures. The noncorrodible GFRP material exhibits linear-elastic stress-strain characteristics up to failure with relatively low modulus of elasticity compared to steel. This raises concerns on GFRP performance in structures where energy dissipation, through plastic behavior, is required. The objective of this research project is to assess the seismic behavior of concrete beam-column joints reinforced with GFRP bars and stirrups. Two full-scale exterior T-shaped beam-column joint prototypes are constructed and tested under simulated seismic load conditions. One prototype is totally reinforced with GFRP bars and stirrups, while the other one is reinforced with steel. The experimen...

2011-01-01

170

Development and application of gamma scanning technology for on-line investigation of industrial process columns and vessels  

International Nuclear Information System (INIS)

Plant Assessment Technology (PAT) group, in association with Intelligent System (IS) Group and Engineering Services Department of Malaysian Institute for Nuclear Technology Research (MINT) has developed gamma scanning facilities for on-line investigation of industrial process columns and vessels. The technology, based on the principle of gamma-ray absorption, has been successfully applied for troubleshooting of a number of distillation columns and process vessels in petroleum refineries, gas processing plants and chemical plants in the country and the region. This paper outlines basic characteristics of the system and describes the inspection procedures, and in addition, case studies are also presented. The case studies are purposely chosen to illustrate the versatility of the technology, and furthermore to demonstrate the economic benefits which can be realised from the application of this technology. (author)

1998-10-30

171

A novel gamma scanning system for on-line diagnostic inspection of industrial process columns  

International Nuclear Information System (INIS)

A computerised gamma scanning facilities for on-line investigation of industrial process columns and vessels has been developed by the Malaysian Nuclear Agency (Nuclear Malaysia). The technology, based on the principle of gamma-ray absorption, has been successfully applied for real-time troubleshooting, process investigation and predictive maintenance of a number of distillation columns and process vessels in petroleum refineries, gas processing plants and chemical plants in the country and the surrounding region. This paper outlines basic characteristics of the system and describes the inspection procedures, and in addition, presents a number of case studies. The case studies are purposely chosen to illustrate the versatility of the technology, and furthermore to demonstrate the economic benefits which can be realised from the application of this technology. (Author)

172

Snow Survey & Water Supply | NRCS  

Science.gov (United States)

Programs & Services Technical Resources Land Use Soils Water Snow Survey & Water Supply Water Management Water Quality Watersheds Wetlands Air Plants & Animals Energy Climate...

2011-08-21

173

{sup 99m}Tc generator preparation using (n, {gamma}){sup 99}Mo produced ex-natural molybdenum  

Energy Technology Data Exchange (ETDEWEB)

Theoretical assessment on the chromatographic {sup 99m}Tc generator preparation using (n, {gamma}) {sup 99}Mo produced ex-natural molybdenum was carried out. The relationship between the neutron flux for MoO{sub 3} target activation, Mo-content or Mo adsorption capacity of column packing material, {sup 99m}Tc pertechnetate concentration and/or {sup 99m}Tc radioactivity of eluate was established. The reasonably lower limit of neutron flux of reactor and Molybdenum content of column packing material were found out to estimate the production of portable chromatographic generators available for nuclear medicine application. The concentration of {sup 99m}Tc pertechnetate eluate of low {sup 99m}Tc concentration using the column elution technique was also evaluate theoretically and conducted successfully in practice. Three options of {sup 99m}Tc generator using Titanium-Molybdate, Zirconium-Molybdate and Zirconium Oxide as ...

2003-03-01

174

Post-column reaction detector for platinum(II) antieoplastic agents  

Energy Technology Data Exchange (ETDEWEB)

The development and evaluation of a post-column reaction detector sensitive to platinum(II) complexes is presented in which sodium bisulfite is used as the derivatizing agent with potassium dichromate as an activating agent. The influences of mobile phase changes (i.e., pH, organic modifiers, electrolytes), oxygen, metal ions, and order of reagent addition on reaction kinetics and product yield are defined and used in optimization of detector response. Detection at lambda/sub max/ 290 nm results in an on-line post-column sensitivity of 40-60 ng/mL for selected cis-dichloroplatinum complexes and a sensitivity of 300-1200 ng/mL for four (substituted)-malonato-platinum complexes. The reaction detector is used to monitor the kinetics of aquation of cisplatin (CDDP) and to quantitate CDDP degradation in plasma. As the sensitivity for CDDP in plasma is comparable to that achieved from high pressure liquid chromatography (HPLC) effluent ...

1984-03-01

175

Modification of Spatial Distribution of 2,4-Dichlorophenoxyacetic Acid Degrader Microhabitats during Growth in Soil Columns  

UK PubMed Central (United Kingdom)

Bacterial processes in soil, including biodegradation, require contact between bacteria and substrates. Knowledge of the three-dimensional spatial distribution of bacteria at the microscale is necessary...Full Text Available

2004-05-01

176

Energy-resolved electron particle and energy fluxes in positive column plasmas  

Energy Technology Data Exchange (ETDEWEB)

This paper deals with electron flux densities and electron energy flux densities in positive column discharges. Recent kinetic calculations by Uhrlandt and Winkler have revealed the interesting physical phenomenon of radially inward directed energy flux densities in positive column plasmas. We have used a self-consistent positive column model, based on an accurate and highly detailed Monte Carlo code, to study this effect in more depth. The results of this study show a rather complex physical picture of electron particle and energy flux densities. Electrons with low energies usually exhibit radially outward directed particle and energy flux densities. At energies above the threshold for electronic excitation particle and energy flux densities are usually inward directed. Only close to the wall, at total energies above the wall potential energy, do these flux densities point towards the wall. The thickness of this ...

1999-11-07

177

Clarke's Column Neurons as the Focus of a Corticospinal Corollary Circuit  

UK PubMed Central (United Kingdom)

Proprioceptive sensory signals inform the CNS of the consequences of motor acts, but effective motor planning involves internal neural systems capable of anticipating actual sensory feedback....Full Text Available

2010-10-01

178

Characterization of group A streptococcal T-12 protein purified by ion-exchange column chromatography.  

UK PubMed Central (United Kingdom)

The aim of the present study was to describe the physicochemical characteristics of streptococcal T antigen. T protein isolated from Streptococcus pyogenes type 12 (R53/1077, Colindale) and purified...Full Text Available

1978-09-01

179

Calculation of cosmic ray antiproton-proton ratio  

Energy Technology Data Exchange (ETDEWEB)

Cross section parameterizations for antiproton production in pp collisions are used to predict the antiproton/proton ratio resulting from a flux of cosmic protons with energy spectral index of 2.6 interacting with a 5 gm/cm/sup 2/ column density of H. (GHT)

1980-01-01

180

Bacterial Oxidation of Sulfide Minerals in Column Leaching Experiments at Suboptimal Temperatures  

UK PubMed Central (United Kingdom)

The purpose of the work was to quantitatively characterize temperature effects on the bacterial leaching of sulfide ore material containing several sulfide minerals. The leaching was tested at eight...Full Text Available

1992-02-01

181

BIOASSAY AND CHEMICAL ANALYSIS FOR HAZARDOUS MATERIALS IN RESIDUAL OILS. VOLUME 2. APPENDICES  

Science.gov (United States)

The report gives results of an examination, including mutagenic screening, of the chemical composition of residual fuel oils and their column chromatography pre-fractions. A degree of correlation between composition and mutagenicity has been achieved. Radionuclide data has been o...

182

Anion-exchange extraction of cephapirin, cefotaxime, and cefoxitin from serum for liquid chromatography.  

UK PubMed Central (United Kingdom)

An anion-exchange column technique for extraction of antibiotics from serum proteins has been developed for use in the assay of cephapirin, cefotaxime, and cefoxitin by high-pressure liquid chromatography....Full Text Available

1982-04-01

183

A Comparative Perspective on Minicolumns and Inhibitory GABAergic Interneurons in the Neocortex  

UK PubMed Central (United Kingdom)

Neocortical columns are functional and morphological units whose architecture may have been under selective evolutionary pressure in different mammalian lineages in response to encephalization and specializations...Full Text Available

184

Study on reactor building structures using ultrahigh strength materials - Part 8: Results of mixed structure tests  

International Nuclear Information System (INIS)

The mixed structure of a nuclear reactor building is composed of SC-columns, S-beams, S-joints and PCa-panels. Following the last report (Part 7)[1], the main test results of the mixed structure, that is, the deformation mode, strain distribution and shear strength, are described. The S-joints using ultrahigh strength materials had no buckling nor shear slipping. The proposed mixed structure resisted the external horizontal forces under integrated uniformity among SC-columns, S-joints and PCa-panels. It could be confirmed that the mixed structure can be established. (author)

1993-08-15

185

Optogalvanic isotope enrichment of Cu ions in Cu-Ne positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

The isotopic enrichment of copper ions in a positive column Cu-Nu discharge using optogalvanic excitation is analyzed with a rate equation model With excitation at 510.6 nm, the fraction of the ions belonging to the 63-amu isotope of copper is enriched relative to the neutral abundance. Enrichment as large as 10% is calculated when the initial abundance of the neutral isotope is small (< or =0.1) and the discharge current density is large (> or =75 mA/cm/sup 2/). The degree of enrichment is examined as a function of the initial abundance, discharge current, the rate of charge exchange, and the diameter of the discharge tube.

1983-07-01

186

Experimental study on the volatile ruthenium decontamination factor of the perforated plate column scrubber  

International Nuclear Information System (INIS)

During a high temperature treatment of the radioactive wastes that contain ruthenium, some ruthenium is volatilized and released to the off gas system. The volatilized ruthenium is removed with a scrubber and an adsorber. It was expected that the scrubber was one of the most effective equipments to remove ruthenium and the decontamination factor of the scrubber was studied. The experimental apparatus was simulated as part of an actual perforated plate column scrubber. The non-radioactive ruthenium which simulated the radioactive ruthenium was volatilized and fed into the scrubber. The decontamination factor of the scrubber was determined by the ratio of the ruthenium concentration at the inlet and outlet of the scrubber off gas stream. The results showed that the scrubber removed the volatile ruthenium effectively as expected.

1993-07-01

187

Experimental studies of selective acid gas removal: Absorption of hydrogen sulfide and carbon dioxide into aqueous methyldiethanolamine using packed columns  

Energy Technology Data Exchange (ETDEWEB)

The use of aqueous methyldiethanolamine (MDEA) for selective removal of hydrogen sulfide from acid gas streams has been studied in a 2 inch column packed with 1/4 inch ceramic Intalox saddles. The column was operated in a counter-current, steady state fashion. The feed gas composition varied between 1 and 5 mole % hydrogen sulfide and between 0 and 50 mole % carbon dioxide. In order to assist the development of packed column absorption models, the rate at which pure carbon dioxide absorbs into 2 M MDEA was measured as a function of pressure, liquid flow rate and packed bed length. The importance of end effects was carefully evaluated. In addition, draining and tracer methods were used to estimate the amount of static holdup present in the column. Using classical draining methods, as much as 50 % of the total holdup was found to be static. However, according to the step decrease in tracer method, less ...

1988-01-01

188

Low-pH injection grout for deep repositories. Summary report from a co-operation project between NUMO (Japan), Posiva (Finland) and SKB (Sweden)  

Energy Technology Data Exchange (ETDEWEB)

The use of standard cementitious material creates pulses of pH in the magnitude of 12-13 in the leachates and release alkalis. Such a high pH is detrimental and also unnecessarily complicates the safety analysis of the repository. As no reliable pH-plume models exist, the use of products giving a pH below 11 in the leachates facilitates the safety analysis. Also, according to current understanding, the use of low-pH cement (pH = 11) will not disturb the functioning of the bentonite, although limiting the amount of low-pH cement is recommended. A result of the project is that there are both low-pH cementitious material for grouting larger fractures (= 100 {mu}m) and non-cementitious material for grouting smaller fractures (< 100 {mu}m) that will, after further optimisation work, be recommended for grouting of deep repositories. This project concentrated on the technical development of properties for the low pH grouts. Long-term safety and environmental aspects and durability of ...

2005-06-01

189

Phosphorus, nitrogen, and radionuclide retention and leaching from a Joel sand amended with red mud/gypsum  

International Nuclear Information System (INIS)

The leaching of phosphorus (P), nitrogen (N), and radionuclides "2"3"2Th, "2"2"6Ra, "2"2"8Ra, and "4"0K from Joel sands amended with red mud/gypsum (RMG) at 9 rates (0, 2, 4, 8, 16, 32, 64, 128, and 256 t/ha) was measured using columns. Intense leaching conditions (34 mm/day for 12 days) and a high rate of applied P (320 kg/ha as superphosphate) and N (680 kg/ha as ammonium nitrate) were used to simulate extremes of irrigated vegetable production on the Swan Coastal Plain. Addition of the highest rate of RMG (256 t/ha) reduced leaching of fertiliser P and ammonium-nitrogen (NH4-N) by 85% and 50%, respectively, compared with 0 t/ha after 12 days. At 64 t RMG/ha P leaching was reduced 50% compared with 0 t/ha. Nitrate-nitrogen (NO3-N) leaching was not affected by addition of RMG. Reduced leaching of NH4-N was attributed to an increase in cation exchange capacity of the soil with the addition of RMG. Bicarbonate-extractable P in the soil increased with rate of RMG to ...

190

Kootenai River Nutrient Dosing System and N-P Consumption: Year 2008.  

Science.gov (United States)

In early 2006 we designed and built low energy consumption, pump-operated system, for dosing of the liquid nutrient in the summer 2006 season. This operated successfully, and the system was used again during the 2007 and 2008 seasons for dosing. During the early winter period, 2008, laboratory tests were made of the liquid nutrient pump system, and it was noted that small amounts of air were being entrained on the suction side of the pump, during conditions when the inlet pressure was low. It was believed that this was the cause of diurnal fluctuations in the flow supplied, characteristic of the 2007 year flow data. Replacement of '0' rings on the inlet side of the pumps was the solution to this problem, and when tested in the field during the summer season, the flow supplied was found to be stable. A decision was made by the IKERT committee at the meeting of 20th to 21st May 2008 (held in Coeur d'Alene, Idaho) to use an injection flow rate of liquid ...

2009-02-19

191

Aerosol Properties Over the United Arab Emirates and Arabian Gulf from MISR Multi-angle Satellite Imaging  

Science.gov (United States)

The MISR instrument aboard NASA's Terra satellite participated in the UAE-2 campaign, August-October 2004. This campaign represented a unique opportunity to study the complex aerosol situation in the Arabian Gulf region, in the context of a first-rate collection of aircraft and surface-based instruments, giving us the opportunity to do some groundbreaking satellite aerosol validation work. We aimed (1) to validate MISR aerosol retrieval results for dust and pollution particles over dark and light surfaces, and (2) to contribute regional maps of aerosol optical thickness (AOT) and particle micro-physical properties, giving spatial context to the field-instrument measurements, and moving toward a satellite-based regional aerosol climatology. The validation effort benefited from the combination of an instrumented aircraft and a regional network of surface-based sun photometers. We obtained high-quality sub-orbital data coincident with MISR overpasses on three days: September 01, 10, and ...

2005-12-01

192

A deterministic partial differential equation model for dose calculation in electron radiotherapy  

International Nuclear Information System (INIS)

High-energy ionizing radiation is a prominent modality for the treatment of many cancers. The approaches to electron dose calculation can be categorized into semi-empirical models (e.g. Fermi-Eyges, convolution-superposition) and probabilistic methods (e.g. Monte Carlo). A third approach to dose calculation has only recently attracted attention in the medical physics community. This approach is based on the deterministic kinetic equations of radiative transfer. We derive a macroscopic partial differential equation model for electron transport in tissue. This model involves an angular closure in the phase space. It is exact for the free streaming and the isotropic regime. We solve it numerically by a newly developed HLLC scheme based on Berthon et al (2007 J. Sci. Comput. 31 347-89) that exactly preserves the key properties of the analytical solution on the discrete level. We discuss several test cases taken from the medical physics literature. A test case with an academic ...

2010-07-07

193

The French design code: RCC-M status and on-going developments  

International Nuclear Information System (INIS)

Since 1978, an important effort has been on-going between Framatome and Electricite de France (EDF) to develop and update technical rules for the design and construction of nuclear power plants. Two design codes are developed, one for PWRs: RCC-M and one for FBRs: RCC-MR. After some comments on the organization of RCCM Commission, the paper presents: (1) the major differences with the ASME Section III Code for fatigue, plastic shakedown and rupture analysis; (2) the review of some important facts in terms of availability or maintenance costs (in-service inspection, replacements, repairs, etc.) of operating plants like underclad cracking, stratification, CRDM nozzles, cast elbows, steam generator tubes, etc.; (3) how can one take into consideration this operating feedback in RCC-M Code; and (4) few examples of major on-going developments for fracture analysis on different components and fatigue analysis of valves. In conclusion, the standardization of the plants is ...

1996-07-21

194

Staged direct injection diesel engine  

Energy Technology Data Exchange (ETDEWEB)

A diesel engine having staged injection for using lower cetane number fuels than No. 2 diesel fuel. The engine includes a main fuel injector and a pilot fuel injector. Pilot and main fuel may be the same fuel. The pilot injector injects from five to fifteen percent of the total fuel at timings from 20.degree. to 180.degree. BTDC depending upon the quantity of pilot fuel injected, the fuel cetane number and speed and load. The pilot fuel injector is directed toward the centerline of the diesel cylinder and at an angle toward the top of the piston, avoiding the walls of the cylinder. Stratification of the early injected pilot fuel is needed to reduce the fuel-air mixing rate, prevent loss of pilot fuel to quench zones, and keep the fuel-air mixture from becoming too fuel lean to become effective. In one embodiment, the pilot fuel injector includes a single hole for injection of the fuel and is directed at approximately 48.degree. below the head of the cylinder.

1985-01-01

195

Indoor air quality and thermal comfort studies of an under-floor air-conditioning system in the tropics  

Energy Technology Data Exchange (ETDEWEB)

This paper reports thermal comfort and indoor air quality (IAQ) studies of an under-floor air-conditioning (UFAC) system in a hot and humid climate. Thermal comfort parameters were measured at pre-determined grid points within an imaginary plane to predict the air flow pattern of the supply air jet as well as to determine the occurrence of thermal stratification in the office space. Fanger's thermal comfort index was also computed to detect the occupants' thermal sensation. Besides, the concentration levels of dust and carbon dioxide were recorded with the intention to examine the quality of the indoor air. Statistical methods were applied to derive the relationship between air velocity and the other parameters as mentioned earlier. The main findings from the study revealed reasonable level of acceptability of IAQ associated with the UFAC system. However, occupants are likely to experience localised thermal discomfort near the supply diffusers due ...

2002-07-01

196

Experimental simulation of heat transfer augmentation by break-jets in passive containment cooling system  

International Nuclear Information System (INIS)

The studies of forced jet augmentation of natural convection heat transfer are introduced. It investigates experimentally mixed convection and heat transfer augmentation by forced jets in a large rectangular enclosure with a vertical cooling surface. The experiment is designed to measure the key parameters governing the heat transfer augmentation by a forced jet, and to investigate the effects of geometric factors, including the jet diameter, jet injection orientation, interior structures, and enclosure aspect ratio, on conditions simulating those of actual passive containment cooling systems and scales approaching those of actual containment buildings or compartments. The tests that cover a variety of injection modes will contribute to reveal the nature of mixing and stratification phenomena under accident conditions to a new generation of inherently safe reactors. With similarity considerations on governing equations, the heat transfer of mixed convection can be ...

2010-02-01

197

Development of a best estimate auditing code for CANDU thermal hydraulic safety analysis  

Energy Technology Data Exchange (ETDEWEB)

The main purpose of this study is to develop a thermal hydraulic auditing code for the CANDU reactor, modifying the model of existing PWR auditing tool , i.e. RELAP5/MOD3. This scope of project is a fourth step of the whole project, applying the RELAP5/MOD3/CANDU+ version for the real CANDU plant LOCA Analysis and D2O leakage incident. There are three main models under investigation, i.e. Moody critical flow model, flow regime model of horizontal CANDU bundle, and fuel element heatup model when the stratification occurs, especially when CANDU LOCA is tested. Also, for Wolsung unit 1 D2O leakage incident analysis, the plant behavior is predicted with the newly developed version for the first 1000 seconds after onset of the incident, with the main interest aiming for system pressure, level control system, and thermal hydraulic transient behavior of the secondary system. The model applied for this particular application includes heat transfer model of nuclear fuel ...

2001-03-01

198

Water Quality Criteria | Water Quality Criteria | US EPA  

Science.gov (United States)

for? Learn the Issues Science & Technology Laws & Regulations About EPA Contact Us Water: Water Quality Criteria You are here: Water Science & Technology Surface Water Standards &...

2011-08-28

201

Photocatalytic oxidation and reduction chemistry and a new process for treatment of pink water and related contaminated water  

Energy Technology Data Exchange (ETDEWEB)

The objective of this project was to develop new photocatalytic or other innovative process chemistry for the treatment of pink water and related contaminated water.

1996-10-01

202

SOLVENT EXTRACTION OF CESIUM BY DIPICRYLAMINE. III. SEMIWORKS DEMONSTRATION  

Science.gov (United States)

The extraction and recovery of cesium from simulated Purex waste solutions was successfully demonstrated in the pilot plant pulse column. Stable volumetric capacities as high as 670 gph/ft/sup 2/ (sum of both phases) were obtained for alkaline supernate-type waste; however, for efficient operation (transfer unit height - HTU -of two feet or less), the maximum throughput rate was limited to about 500 gph/ft/sup 2/. This rate could be achieved with feeds diluted to densities within 0.08 g/cc of the solvent density. Stable feed was prepared from simulated current, denitrated waste by addition of citric acid to complex the iron before neutralization to the desired operating pH of 7 to 8. Capacities of 500 gph/ft/sup 2/ were readily achieved with this feed, together with HTU's of 1.0 to 1.3 feet. Sodium extracted with the cesium was satisfactorily scrubbed from the solvent with a dilute citric acid solution. Scrub section sodium ...

1963-03-15

203

Modelling and simulation of rate-based mechanistic model for CO{sub 2} capture  

Energy Technology Data Exchange (ETDEWEB)

The electric power industry can use the carbon dioxide absorption process to capture carbon from high-volume flue gas. However, the current cost of the process is too high due to the approximation method used in process design. The absorption column is typically designed with parameters that are assumed to be constant over the whole length of the column, resulting in an oversized unit. This approximation method is no longer valid given new environmental and economic concerns. In order to develop an accurate column design for high-efficiency carbon dioxide (CO{sub 2}) capture, it is necessary to understand the phenomena taking place in the system. A mechanistic model is presented for a robust absorber design that takes into account mass-transfer and hydrodynamic behaviour within the CO{sub 2} absorption columns. The capture performance of a packed column under a wide range of design ...

2003-07-01

204

Water resources data for Oklahoma, water year 1992. Volume 2. Red River Basin. Water-data report (Annual), 1 October 1991-30 September 1992  

Energy Technology Data Exchange (ETDEWEB)

Volume 2 of the water resources data for the 1992 water year for Oklahoma consists of record of stage, discharge, and water quality of streams; stage, contents, and water quality of lakes or reservoirs; and water levels of ground-water well. The report contains discharge records for 136 gaging stations; stage and contents for 31 lakes or reservoirs; water quality for 50 gaging stations. Also included are 61 partial-record or miscellaneous streamflow stations and 28 ground-water sites.

1993-04-01

205

Safe Water in an Emergency  

Medline Plus

English - Safe Water in an Emergency Click to Stop Video Click to Start Video To Listen to ...

206

VUV efficiency and radiant emittance characterization of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

The pure xenon dc positive column discharge has been characterized for various xenon pressures, currents, and discharge tube radii. The absolute output at the 147 nm resonance transition has been measured using two independent techniques to yield the radiant emittance at 147 nm (power per unit surface area). The efficiency of 147 nm production is obtained by combining the measured radiant emittance with the measured electrical power per unit length deposited in the gas. The radiant emittance and the efficiency are the two principle figures of merit for characterizing the discharge as a source of VUV radiation. It is observed that the trends in efficiency and radiant emittance change substantially when the discharge transitions from two-step electron impact excitation/ionization at higher pressures to single-step electron impact ionization at lower pressures. Modeling of the xenon positive column discharge yields radiant emittance and efficiency ...

1996-12-31

207

Removal of iodine species by concentrated nitric acid, (2)  

International Nuclear Information System (INIS)

One of the most effective removing processes of iodine species is what is called ''Iodox Process'', which contains oxidation and absorption of iodine species by highly concentrated nitric acid. The result of fundamental test with bubble column in this process had been reported. Present paper describes the fundamental experiment by the use of packed column. This experiment has been carried out to clear the effect of feed gas flow rate, nitric acid flow rate, nitric acid concentration, and methyl iodide concentration on removal efficiency of methyl iodide. The following results were obtained. The decontamination factor of methyl iodide (DF) increases exponentially with nitric acid concentration, which agrees with the result obtained by using the bubble column. The factor is in inverse proportion to feed gas flow rate, and is also almost independent of nitric acid flow rate and methyl iodide concentration. The relation between ...

1978-07-01

208

Phenomenological Theory of the Kink Instability in a Slender Plasma Column  

Energy Technology Data Exchange (ETDEWEB)

When one deals with a plasma column whose radius a is much smaller than its length L, one can think of it as of a thin filament whose kink instability can be adequately described simply by a 2D displacement vector, {xi}{sub x} = {xi}{sub s}(z,t); {xi}{sub y} = {xi}{sub y}(z,t). Details of the internal structure of the column such as the current, density, and axial flow velocity distribution would be lumped into some phenomenological parameters. This approach is particularly efficient in the problems with non-ideal (sheath) boundary conditions (BC) at the end electrodes, with the finite plasma resistivity, and with a substantial axial flow. With the sheath BC imposed at one of the end-plates, we find instability in the domain well below the classical Kruskal-Shafranov limit. The presence of an axial flow causes the onset of rotation of the kink and strong axial ''skewness'' of the eigenfunction, with the ...

2005-11-18

209

Independent Emission and Absorption Abundances for Planetary Nebulae  

CERN Document Server

Emission-line abundances have been uncertain for more than a decade due to unexplained discrepancies in the relative intensities of the forbidden lines and weak permitted recombination lines in planetary nebulae (PNe) and H II regions. The observed intensities of forbidden and recombination lines originating from the same parent ion differ from their theoretical values by factors of more than an order of magnitude in some of these nebulae. In this study we observe UV resonance line absorption in the central stars of PNe produced by the nebular gas, and from the same ions that emit optical forbidden lines. We then compare the derived absorption column densities with the emission measures determined from ground-based observations of the nebular forbidden lines. We find for our sample of PNe that the collisionally excited forbidden lines yield column densities that are in basic agreement with the column densities derived for ...

2008-01-01

210

Immobilization of stationary phases onto chromatographic supports by gamma radiation  

International Nuclear Information System (INIS)

Cobalt-60 gamma radiation has been found to be an effective means of immobilizing stationary phases onto gas and liquid chromatographic supports. The ability of a phase to crosslink was determined to be highly dependent on its chemical structure. Gamma radiation was employed to immobilize Se-30, a methylsilicone, and 216 PS onto Chromosorb WHP for packed column chromatography. The resultant columns exhibited increased thermal stability and a high degree of efficiency. Several blended phases containing varying ratios of Se-30:216 PS were also immobilized onto chromatographic packings. This work was further extended to the immobilization of Se-30 and 216 PS onto fused silica capillaries via gamma radiation. Columns exhibited excellent efficiency and improved thermal stability. An investigation into the role of immobilization of polymeric phases for HPLC was undertaken. Results indicate that gamma radiation can immobilzied ...

211

Determination of plutonium in soil samples by ICP-MS after radiochemical separation procedure  

International Nuclear Information System (INIS)

A method was developed for the determination of plutonium in the soil samples by ICP-MS with TOA extraction chromatographic column. The optimized sample loading rate is below 0.2 mL/min (column inner diameter is 3.5 mm). Using hot 0.02 mol/L oxalic acid (H_2C_2O_4) in 0.16 mol/L HNO_3 to elute Pu from the solid phase in the column. The Pu recovery of 87.3%-96.8% in soil samples was obtained. The plutonium is separated with the ion exchange method in this work. Both extraction chroma- tography and ion-exchange methods efficiently remove the uranium and matrix interference from the ICP- MS measurement. The instrumental detection limit for "2"3"9Pu was 0.48 pg/mL, which corresponds to 1, 1 mBq/mL. (authors)

2008-03-01

212

Column leaching test to evaluate the use of alkaline industrial wastes to neutralize acid mine tailings  

Energy Technology Data Exchange (ETDEWEB)

Acid mine drainage is a serious environmental problem caused by the oxidation of sulfide minerals that releases highly acidic, sulfate, and metals-rich drainage. In this study, alkaline industrial wastes were mixed with acid mine tailings in order to obtain neutral conditions. A series of column leaching tests were performed to evaluate the behavior of reactive mine tailings amended with alkaline-additions under dynamic conditions. Column tests were conducted of oxidized mine tailings combined with cement kiln dust, red mud bauxite, and mixtures of cement kiln dust with red mud bauxite. The pH results show the addition of 10% of alkaline materials permits the maintenance of near neutral conditions. In the presence of 10% alkaline material, the concentration of toxic metals such as Al, Cu, Fe, Zn are significantly reduced as well as the number of viable cells (Thiobacillus ferrooxidans) compared to control samples.

2005-08-01

213

Carbon dioxide absorption contactors: hollow fibre membranes and packed absorption columns  

Energy Technology Data Exchange (ETDEWEB)

One of the important aspects in an absorption system is the effectiveness in which the gas and liquid phases come into contact with each other. An effective absorption process will provide sufficient contacting area for the gas and liquid phases to interact upon. With this in mind, work was conducted to evaluate carbon dioxide (CO{sub 2}) absorption into aqueous solutions of monoethanolamine (MEA) using two different types of contacting devices: gas absorption membrane (GAM) modules and traditional packed columns. The performance of these two absorption devices was compared to one another using the overall mass transfer coefficient (K{sub G}a{sub v}) as a basis. The GAM module contained microporous polypropylene hollow fibre membranes and the packed absorption column contained Sulzer DX structured packing. The results indicate that GAM modules tend to have slightly larger K{sub G}a{sub v} values, potentially opening the door for smaller ...

2003-07-01

214

The X-ray Halo of G21.5-0.9  

CERN Document Server

The emission of the plerion G21.5-0.9 appears more extended in X rays than in radio. This is an unexpected result because it would imply that short-lived X-ray electrons may reach distances even larger than radio electrons. Applying an empirical relationship between dust scattering optical depth and photoelectric column density, the measured column density leads to a large optical depth at 1 keV, of about 1. Therefore we investigate the hypothesis that the detected halo be an effect of dust scattering, re-analyzing an Cal/PV XMM-Newton observation of G21.5-0.9 and critically examining it in terms of a dust scattering model. We also present a spectral analysis of a prominent extended feature in the northern sector of the halo.

2003-01-01

215

Sorbent extraction and high performance liquid chromatography (HPLC) of homidium bromide and isometamidium chloride in bovine plasma  

International Nuclear Information System (INIS)

Homidium bromide and isometamidium chloride are used extensively in the treatment of bovine trypanosomiasis in Africa, but no specific and sensitive method to detect the drug in plasma has been published yet. Comparing the methods of other investigators it was found that they could not overcome the protein binding of these drugs which reduced the available and determined drug to 10% of the real concentrations. These techniques overcome the protein binding by enzyme digestion and an alteration of the pH before adding the sample directly on clean-up columns. Drug recover rates above 80% were obtained. For the detection, the HPLC was employed using a C18 reversed phase analytical column and UV detection, determining both drugs as intact molecules. (author).

1992-01-01

216

Separation of lead-203 from cyclotron-bombarded thallium targets by ion-exchange chromatography  

Energy Technology Data Exchange (ETDEWEB)

A simple method is presented for the separation of lead-203 from copper-backed thallium cyclotron targets. The procedure involves cation-exchange chromatography in hydrochloric acid and hydrochloric acid-acetone mixtures. Further purification involves anion-exchange chromatography in nitric acid-hydrobromic acid mixtures. A cation-exchange column containing 3.0 g of resin can handle as much as 15 g of thallium and 160 mg of copper. An anion-exchange column containing 3.0 g of resin can separate lead from up to 200 mg of thallium and 10 mg of copper. Separations are extremely sharp and less than 0.1 ..mu..g of thallium and less than 0.1 ..mu..g of copper remain in the lead-203 fraction.

1982-07-01

217

Separation of lead-203 from cyclotron-bombarded thallium targets by ion-exchange chromatography  

International Nuclear Information System (INIS)

A simple method is presented for the separation of lead-203 from copper-backed thallium cyclotron targets. The procedure involves cation-exchange chromatography in hydrochloric acid and hydrochloric acid-acetone mixtures. Further purification involves anion-exchange chromatography in nitric acid-hydrobromic acid mixtures. A cation-exchange column containing 3.0 g of resin can handle as much as 15 g of thallium and 160 mg of copper. An anion-exchange column containing 3.0 g of resin can separate lead from up to 200 mg of thallium and 10 mg of copper. Separations are extremely sharp and less than 0.1 #mu#g of thallium and less than 0.1 #mu#g of copper remain in the lead-203 fraction. (author).

218

Reinforced concrete beam-column joints with crossed inclined bars under cyclic deformations  

British Library Electronic Table of Contents (United Kingdom)

This experimental study investigates the effectiveness of crossed inclined bars (X-bars) as joint shear reinforcement in exterior reinforced concrete beam-column connections under cyclic deformations. Test results of 20 joint subassemblages with various reinforcement ratios and arrangements including X-bars in the joint area are presented. The X-type, non-conventional reinforcement is examined as the only joint reinforcement and in combination with common stirrups or vertical bars. The experimental results reported herein include full loading cycle curves, energy dissipation values and a categorization of the observed damage modes. Based on the comparisons between the overall hysteretic responses of the tested specimens, it is deduced that joints with X-bars exhibited enhanced cyclic perfo...

2008-01-01

219

Quantitative measurements of injections into porous media with contrast based MRI  

British Library Electronic Table of Contents (United Kingdom)

Porous flow occurs in a wide range of materials and applies to many commercially relevant applications such as oil recovery, chemical reactors and contaminant transport in soils. Typically, breakthrough and pressure curves of column floods are used in the laboratory characterization of these materials. These characterization methods lack the detail to easily and unambiguously resolve flow mechanisms with similar effects at the core scale that can dominate at the aquifer or oil field scale, as well as the effects of geometry that control the flow at interfaces as in a perforated well or the inlet of an improperly designed column. Non-invasive imaging techniques such as MRI have been shown to provide a far more detailed characterization of the properties of the solid matrix and flow, but usu...

2011-01-01

220

Optimization of band gap of photonic crystals fabricated by holographic lithography  

Science.gov (United States)

Generally the photonic band gap (PBG) is a multi-variable function of several parameters related to the shape and size of the dielectric columns of photonic crystals (PhCs), and a time-consuming step-by-step scanning process for each parameter has to be used to find their best combination yielding maximum PBG. In this letter, the widely used Nelder-Mead simplex algorithm is introduced to optimize these parameters simultaneously to find a larger PBG for a new kind of two-dimensional (2D) hexagonal GaAs-Air PhC. This structure can be conveniently produced by the single-exposure holographic lithography, and the specific holographic design is also systematically investigated. This study reveals that the band gaps of PhCs made by holographic lithography may be widened by introducing irregularity of the columns and lowering the symmetry of the structure.

2008-01-01

221

On the radial distribution of gamma rays in the outer galaxy  

International Nuclear Information System (INIS)

The authors describe a new method which makes it possible to determine the radial distribution of the diffuse component of galactic gamma rays outside the solar circle. They use the observation that a good correlation exists between gamma-ray intensities and total column densities of the local interstellar gas and that the fractional column density of H_2<0.1 HI outside the solar circle. Thus the gamma-ray intensities are shown to be proportional to N(HI). The authors use the kinematics of the HI to determine the distances from which various fractions of the emission originate in the second and third galactic quadrants. Preliminary results of our analysis show that a significant flux of gamma rays originates from distances as large as 18 kpc from the galactic centre. (Auth.).

1982-08-04

222

Matrix Coherence and the Nystrom Method  

CERN Document Server

The Nystrom method is an efficient technique to speed up large-scale learning applications by generating low-rank approximations. Crucial to the performance of this technique is the assumption that a matrix can be well approximated by working exclusively with a subset of its columns. In this work we relate this assumption to the concept of matrix coherence and connect matrix coherence to the performance of the Nystrom method. Making use of related work in the compressed sensing and the matrix completion literature, we derive novel coherence-based bounds for the Nystrom method in the low-rank setting. We then present empirical results that corroborate these theoretical bounds. Finally, we present more general empirical results for the full-rank setting that convincingly demonstrate the ability of matrix coherence to measure the degree to which information can be extracted from a subset of columns.

2010-01-01

223

Liquid level control system of fast reactor secondary cooling system  

International Nuclear Information System (INIS)

Object: To minimize the range of the liquid level variation of the cooling system and reduce the time required for the liquid level control by sealing the gas of a cover gas respiration system which acts upon an evaporator and pump overflow column. Structure: In liquid level control by the cover gas pressure of a high-speed reactor secondary cooling system, upon occurrence of a sudden change in the rate of flow of the recirculated liquid, automatic check valves provided in an evaporator and pump overflow column cover gas respiration system are completely or substantially closed, while at the same time the recirculation cooling medium is sucked up and an automatic check valve provided in the overflow system is closed. (Kamimura, M.).

224

Isolation of antibodies specific to sickle hemoglobin by affinity chromatography using a synthetic peptide  

International Nuclear Information System (INIS)

Antibodies to hemoglobin have been studied with a radioimmunoassay which employs ["1"4C]carbamylated (= carbamoylated) hemoglobin S. An antiserum raised against hemoglobin S, which initially discriminated poorly between hemoglobins S and A, was fractionated by absorption to a column of Sepharose to which a synthetic peptide corresponding to the first 13 amino-acid residues of the #beta# chain of sickle hemoglobin had been covalently bound. A subpopulation of the antiserum was eluted from this column with 4 M guanidine . HCl. These antibodies showed binding to hemoglobin S but not to hemoglobin A and this interaction could be inhibited by the synthetic peptide. These antibodies, of demonstrated fine structural specificity, may be useful in the detection of sickle hemoglobin and in the study of its structure in solution.

225

Gas chromatography - mass-spectrometry of volatiles released from plastics used as building materials  

Energy Technology Data Exchange (ETDEWEB)

The possibility of employing a number of adsorbents (polyphenylquinoxaline, Tenax GC, Carbopak C, graphitized thermal carbon black, silica gels modified with pyrocarbon or hexamethyldisilazane) for the trapping of organic traces from air has been investigated. Adsorption capacities of these adsorbents with respect to a number of volatiles released from certain plastics used as building material (polyvinylchloride, Relin, Acronal, etc.) have been measured. A number of the volatiles were identified by gas chromatography - mass-spectrometry after trapping on the adsorbents investigated. Chromatographic separation after trapping on the adsorbents was carried out on wall-coated open-tubular capillary columns as well as in capillary columns packed with graphitized thermal carbon black.

1983-10-01

226

Ewing's sarcoma of the vertebral column  

International Nuclear Information System (INIS)

Twenty-two patients with vertebral primaries were registered in the Intergroup Ewing's Sarcoma Study between 1973 and 1977. The radiation doses to the primary tumors ranged between 3800 and 6200 rad. All patients received intensive combination chemotherapy. After a followup ranging between 14 and 62 months, 14 patients remained disease-free. All patients with primary tumor of the cervical and dorsal spine remained disease-free. Of eight patients with lesions in the distal spine, (sacrococcygeal region) six developed recurrence, in three a local recurrence was observed despite doses of 6000 rad or higher. Doses of 5000 rad or less (in addition to combination chemotherapy as used in the Intergroup Ewing's Study) appear adequate in controlling the primary tumors of the proximal segments of the spinal column.

227

Dynamic optimization of the benzene extractive distillation unit  

Scientific Electronic Library Online (English)

Abstract in english A mathematical model has been developed for describing the dynamic operation of the N-formylmorpholine extractive distillation column and the corresponding solvent recovery column in the benzene extraction plant. The NRTL equation was used to calculate the equilibrium and thermodynamic properties of the mixtures. The validity of the model in terms of temperature, pressure and split fraction was examined using actual plant data at steady-state conditions. Comparison betwee (more) n model results and plant data shows good consistency. In order to improve the control of the process and selection of the optimal control strategy, the model was used to find the optimum values of the constants of the controllers with Nelder-Mead algorithm during unsteady-state operation by minimizing the deviation from steady-state conditions. The outcome of this study could be used by operators and engineers to increase the productivity of the ...

2008-12-01

228

Automatic sample preparation of sulfonamide antibiotic residues in chicken breast muscle by using dynamic microwave-assisted extraction coupled with solid-phase extraction  

British Library Electronic Table of Contents (United Kingdom)

Abstract In the work, a rapid, simple and high-throughput sample preparation method was developed for the determination of sulfonamide (SA) antibiotic residues in chicken breast muscle. The extraction and clean-up were online combined and up to 20 samples can be treated simultaneously in 6-min. The SAs were first extracted with acetonitrile under the action of microwave energy, and then the extract was directly introduced into the SPE column for on-line clean-up and concentration. Subsequently, the SAs eluted from the SPE column were determined by liquid chromatography-tandem mass spectrometry. The precisions of extraction results of 20 samples were in the range of 4.9-7.4%. The limits of detection and quantification obtained were in the range of 2.4-3.6-ng/g and 8.6-11.3-ng/g for SAs, res...

2011-01-01

229

Angiopoietin Balance in Septic Shock Patients With Acute Lung Injury: Effect of Direct Hemoperfusion With Polymyxin B-Immobilized Fiber  

British Library Electronic Table of Contents (United Kingdom)

Abstract Acute lung injury (ALI) in sepsis is characterized by an increase in microvascular permeability, resulting in pulmonary edema. Several studies have suggested that angiopoietin-1 and -2 play a contributory role in the pathogenesis of ALI. Polymyxin B-immobilized fiber column hemoperfusion is effective for sepsis-induced ALI. We investigated the angiopoietin levels before and after direct hemoperfusion with polymyxin B-immobilized fiber column (PMX) therapy. Enzyme-linked immunoassay was used to measure the serum angiopoietin-1 and -2 levels in 25 patients with septic shock treated with PMX. Eleven of the 25 patients were diagnosed with ALI. There was a significant positive correlation between the angiopoietin-1 level and the PaO2/FiO2 ratio, but there was a significant inverse corr...

2011-01-01

230

Water resources data for Minnesota, water year 1993. Volume 2. Upper Mississippi and Missouri River basins. Water-data report (Annual), 1 October 1992-30 September 1993  

Energy Technology Data Exchange (ETDEWEB)

Water-resources data for the 1993 water year for Minnesota consists of records of stage, discharge and water quality of streams; stage, contents, and water quality of lakes and reservoirs; and water levels and water quality in wells and springs. This volume contains discharge records for 58 gaging stations; stage and contents for 9 lakes and reservoirs; water quality 15 stream stations, 1 lakes station, 1 precipitation station, and water levels for 15 observation wells. Also included are 61 high-flow partial-record stations. Additional water data were collected at various sites, not part of the systematic data collection program and are pulished as miscellaneous measurements.

1994-07-01

231

Water resources data for Minnesota, water year 1991. Volume 2. Upper Mississippi and Missouri River Basins. Water-data report (Annual), 1 October 1990-30 September 1991  

Energy Technology Data Exchange (ETDEWEB)

Water-resources data for the 1991 water year for Minnesota consist of records of stage, discharge and water quality of streams; stage, contents, and water quality of lakes and reservoirs; and water levels and water quality in wells and springs. The volume contains discharge records for 60 gaging stations; stage and contents for 9 lakes and reservoirs; water quality for 18 stream stations, 1 lake station, 22 partial-record sites, 1 precipitation station, 108 wells; and water levels for 119 observation wells. Also included are 59 high-flow partial-record stations. Additional water data were collected at various sites, not part of the systematic data collection program and are published as miscellaneous measurements or low-flow investigations.

1992-09-01

232

National Water Plan draft  

International Nuclear Information System (INIS)

In the National Water Plan it is described which measures must be taken to keep the Netherlands safe and livable for future generations and to make use of the chances offered by water.

233

CDC Data & Statistics | Feature: Drowning Risks in Natural Water...  

Science.gov (United States)

swimmers in or around the water. Designate a responsible adult who can swim and knows CPR to watch swimmers in or around water. The supervisor should not be involved in any...

2011-09-24

234

What Can a Dual beam Really Do?  

International Nuclear Information System (INIS)

Full Text: Smallstage Dualbeam (SDB) systems, that is a Focussed Ion Beam column coupled with a SEM column, have been around for about five years now. There impact on the Semiconductor industry has been enormous, with virtually every lab having a SDB to produce, characterise and analyse cross sections and TEM samples on the Nano-scale. But what about other industries? What else can SDB system be used for? The SEM column in itself is a very powerful tool for sample characterisation, modification and analysis. An electron beam from a Tungsten or Thermal Field Emission source has enough current to allow sophisticated patterns to be created in photo-resist samples, a process known as lithography. The current is also high enough to allow for a process known as Electron Beam Induced Deposition (EBID), where the beam interacts with an introduced gas and material is deposited in a controlled manner on the sample. With the addition ...

2005-08-16

235

The origin and physical mechanism of the ensemble Baldwin effect  

CERN Document Server

We have conducted a systematic investigation of the origin and underlying physics of the line--line and line--continuum correlations of AGNs, particularly the Baldwin effect. Based on the homogeneous sample of Seyfert 1s and QSOs in the SDSS DR4, we find the origin of all the emission-line regularities is Eddington ratio (L/Ledd). The essential physics is that L/Ledd regulates the distributions of the properties (particularly column density) of the clouds bound in the line-emitting region.

2009-01-01

236

The harmful effect of phosphate in yellow cake on the TBP purification process  

International Nuclear Information System (INIS)

The harmful effect of phosphate in yellow cake on the TBP purification process and its removal methods are dealed with. The reason of more uranium loss in residue was analyzed. The harmful effect of phosphate on TBP extraction efficiency and operaton of extraction column was discussed. The limit value of uranium concentration in digestion solution was presented. For TBP purification process, the presence of phosphate in yellow cake does more harm than good. (authors)

2009-02-01

237

Study of multiphase flow useful to understand scaleup of coal liquefaction reactors. 1981-1984 final report  

Energy Technology Data Exchange (ETDEWEB)

Research over a three year time span involved the study of multiphase flow useful to understanding the scaleup of coal liquefaction reactors. We attempted to establish the flow patterns and their boundaries in which a direct coal liquefaction, large diameter, bubble column operates. A flow map has been proposed in which coal slurry properties can be input to determine the flow pattern boundaries at reactor operating conditions. Gas holdup and bubble diameters have been measured under different conditions of gas and liquid flow rate. These have been used to determine interfacial area in bubble columns. An equation for the estimation of interfacial area in the bubble-slug flow pattern has been proposed. It has also been established that gas holdup and thus interfacial area depends strongly on the gas distribution in the column. Porous plate gas distributors can yield gas holdups twice as large as sieve plate distributors. ...

1984-09-01

238

Solar-powered humidification dehumidification desalination system  

Energy Technology Data Exchange (ETDEWEB)

Presented are some preliminary studies made in preparation for the design of a solar powered loop for desalination by humidification - dehumidification process. The studies concentrated on the evaluation of different parameters affecting the performance of the combination of different components in such a loop in the hope of outlining the most decisive factors for the choice or design of solar collectors or heat source. The results presented relate to the performance of two of the most important components in a loop of such purpose, that is: the humidifying and the dehumidifying columns or stacks. 4 refs.

1980-01-01

239

Research efforts to produce a {sup 99}Mo-{sup 99m}Tc generator using reactor-produced {sup 99}Mo  

Energy Technology Data Exchange (ETDEWEB)

Recognizing the importance of {sup 99m}Tc and {sup 99m}Tc-based radiopharmaceuticals in nuclear medicine, the Philippine Nuclear Research Institute has initiated research on the development of column-type generators for {sup 99m}Tc using {sup 99}Mo in the form of a gel. The use of reactor-produced {sup 99}Mo will reduce the country's dependence on the importation of commercial generators based on fission product molybdenum-99. However, the relatively low specific activity of {sup 99}Mo must be compensated by the high adsorption capacity of the column material for molybdenum. A procedure based on the incorporation of low activity {sup 99}Mo into a zirconium molybdate gel matrix was adopted with reasonable success. Because the properties of the gel vary considerably with conditions of synthesis, the following parameters were carefully controlled: pH, concentration, temperature, order of mixing of the reactant solutions and conditions of ...

2003-03-01

240

Plant for processing sewage gas to natural-gas quality  

Energy Technology Data Exchange (ETDEWEB)

Sewage gas or biogas as a product of anaerobic digestion contains methane and carbon dioxide as its main components. Biogas is scrubbed off carbon dioxide in absorption columns and purified to natural-gas quality. The purified gas then is piped to the gas pressure control station and fed into the public network. Description of process and plant is given.

1983-09-01

241

NAME=\\  

Wastenet

... Further complications resulted from the requirement to use existing piled foundations and columns which had originally been designed to accommodate a six-storey office block. The hotel bedroom configurations and planning constraints were different from thos Related Services Structural Design Go View all Services Find Projects Sector All Sectors Buildings & Infrastructure Environment Natural Resources Transportation Sub Sector All Sub-Sectors Country All Countries Angola Antigua and Barbuda Argentina Australia Azerbaijan ...

242

Mandrel head for pressing out patches during repair of casing columns  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this invention is to assure operating reliability of a Mandrel head in tubes of various diameters. This goal is achieved in that it is equipped with movable expanding sectors, which are installed on a rigid conical plunger dye. It is also equipped with spring-loaded conical slides blocks which are installed on a shaft. The upper ends of the sectors of the sectorial head are attached by hinges to a rigid cone shaped plunger dye. The lower ends are installed with the possibility of interacting with the slide blocks.

1980-07-17

243

Investigation of carbon dioxide absorption by absorbents impregnated with alkanol amines  

Energy Technology Data Exchange (ETDEWEB)

In studying the absorption of carbon dioxide by absorbents impregnated with alkanol amines, researchers used a laboratory-scale packed column to determine the overall gas-phase mass-transfer coefficients and enhancement factors. A model derived for the mechanism of the chemical reaction taking place in the interfacial layer accounts for the effect of the reaction upon the absorption rate better than other models.

1981-01-01

244

Full scale heavily reinforced concrete beam-column joints of NPP structures-quality assurance and construction in the laboratory  

International Nuclear Information System (INIS)

Under the current design philosophy, reactor structures are to be designed to withstand large inelastic deformation caused by strong and severe ground motion. The design of the main structural elements and their connections are to be such that they always fail in ductile mode. This will ensure large energy absorption capacity of the structures under seismic excitation and avoid sudden and brittle failure of the structure. Over the years, a number of experimental investigations have been carried out on RC beam- column joints to study their behaviour and strength. However, these studies mostly pertain to small scale joints of moment resisting frame of residential buildings and commercial complexes. Information on full scale joints existing in NPP structures are scanty. Therefore, experimental programme was planned in the laboratory to construct identical large sized joints with the same reinforcement percentage and detail as that of the existing joints in NPP ...

2003-02-01

245

Enrichment of americium-242m and americium-242 isotopes by means of Szilard-Chalmers method using americium-241 diphthalocyanine complex  

International Nuclear Information System (INIS)

Results of americium-242m and americium-242 preparation by irradiating initial americium-241 at a reactor in the form of a diphtalocyanine complex are presented. The enrichment coefficient, equalling 10, has been obtained using the extraction method of recoil atom separation from the parent isotope. Application of the chromatographic column with Dowex-50 permits to increase the enrichment coefficient of isotopes upto 24.6.

246

Enrichment of americium 242m and americium 242 isotopes by the Szilard-Chalmers method using an americium-242 diphthalocyanine complex  

Science.gov (United States)

Americium 242m and americium 242 were prepared by reactor irradiation of americium 241 as its diphthalocyanine complex. The product atoms were extracted from the parent isotope at an enrichment factor of 10. A Dowex 50 chromatographic column raised the factor to 24.6.

1987-05-01

247

Enrichment of americium 242m and americium 242 isotopes by the Szilard-Chalmers method using an americium-242 diphthalocyanine complex  

International Nuclear Information System (INIS)

Americium 242m and americium 242 were prepared by reactor irradiation of americium 241 as its diphthalocyanine complex. The product atoms were extracted from the parent isotope at an enrichment factor of 10. A Dowex 50 chromatographic column raised the factor to 24.6.

248

Diagnostic and Therapeutic RI Generators  

Energy Technology Data Exchange (ETDEWEB)

Different types of generators have been developed for the convenient use of {sup 99m}Tc as the demand for this radioisotope is strong. Currently, the demand for {sup 99m}Tc is more than 80 % of the total demand for medical isotopes in the world. A {sup 99m}Tc generator, in general, is composed of a column packed with ceramic adsorbent, tubing, eluent reservoir or vials, collection vials, and shielding. The key technology to develop a good generator is how to load {sup 99}Mo as much as possible while maintaining the quality of eluted {sup 99}mTc as good as possible. The technology is well developed and already available commercially for the case of the fission {sup 99}Mo/{sup 99}mTc because loading of few curries of {sup 99}Mo on a conventional adsorbent, i.e. alumina is not a serious task in the chemical point of view. However, the current infrastructure of the supply of {sup 99}Mo to the world market is sturdy as the research reactors are getting aged. In this ...

2006-07-01

249

Continuous control of ionization wave chaos by spatially derived feedback signals  

CERN Document Server

In the positive column of a neon glow discharge, two different types of ionization waves occur simultaneously. The low-dimensional chaos arising from the nonlinear interaction between the two waves is controlled by a continuous feedback technique. The control strategy is derived from the time-delayed autosynchronization method. Two spatially displaced points of observation are used to obtain the control information, using the propagation characteristics of the chaotic wave.

1997-01-01

250

Cation exchange separation of trace amounts of {sup 203}Hg and {sup 181}Hf  

Energy Technology Data Exchange (ETDEWEB)

A radiochemical method of separation of {sup 203}Hg from {sup 181}Hf is described. The method involves separation by Dowex 50W- X 8, 100-200 mesh, cation exchange resin using 1 M hydrochloric acid as the eluant. The chemical yield for the separation of mercury is > 85% and the decontamination factor is >10{sup 4}. The {sup 181}Hf can be eluted from the column by 4 M HCl.

2000-02-01

251

A practical {sup 99m}Tc generator using (n, {gamma}) {sup 99}Mo  

Energy Technology Data Exchange (ETDEWEB)

For a new and practical {sup 99m}Tc generator using not (n, f){sup 99}Mo, but (n, {gamma}){sup 99}Mo, an inorganic polymer adsorbent framed with oxygen-zirconium-chlorine bonds with a high adsorption performance of Mo has been developed; the polymer adsorbent was named PZC. The amounts of {sup 99}Mo (Mo) adsorbed are stably more than 250 mg/g(PZC). But, the current experiments with 0.5 MBq to 1.85 GBq of {sup 99}Mo gave a subject that the breakthrough of {sup 99}Mo in the elution of {sup 99m}Tc from the adsorbent was 0.05-0.5 %, although the breakthrough of Zr was less than the detection limit of 5 x 10{sup -2} mg(Zr) to 1 g of PZC, and {sup 99m}Tc was eluted constantly with 78{+-}4%. To apply the adsorbent as a generator commercially in Japan, the {sup 99}Mo breakthroughed from the generator must be suppressed to less than 0.15 kBp({sup 99}Mo)/MBq({sup 99m}Tc) by law which is equivalent to 0.015 %, and the {sup 99}Mo breakthrough is controlled practically to less than 10{sup -2} of ...

2000-10-01

256

Numerical analysis of a natural convection cooling system for radioactive canisters storage  

International Nuclear Information System (INIS)

This paper describes the use of numerical analysis for studying natural convection cooling systems for long term storage of heat producing radioactive materials, including special nuclear materials and nuclear waste. The paper explains the major design philosophy, and shares the experiences of numerical modeling. The strategy of storing radioactive material is to immobilize nuclear high-level waste by a vitrification process, convertion it into borosilicate glass, and cast the glass into stainless steel canisters. These canisters are seal welded, decontaminated, inspected, and temporarily stored in an underground vault until they can be sent to a geologic repository for permanent storage. These canisters generate heat by nuclear decay of radioactive isotopes. The function of the storage facility ventilation system is to ensure that the glass centerline temperature does not exceed the glass transition temperature during storage and the vault concrete temperatures remain within the ...

1995-02-01

257

Light, temperature and nitrogen as interacting factors affecting diel vertical migrations of dinoflagellates in culture  

Energy Technology Data Exchange (ETDEWEB)

Diel vertial migrations of the marine dinoflagellates Gonyaulax polyedra Stein and Ceratium furca (Ehr.) Clap. et Lachm, were followed in a laboratory tube (2.02 m x 0.25 m) under a 12:12h light:dark cycle. The effects of temperature stratification, two levels of surface irradiance and nitrogen depletion on patterns of vertical migrations were examined. At temperatures between 22 to 26/sup 0/C with small temperature gradients, both species migrated at a rate of 0.7 to 1.0 mh/sup -1/. Steeper thermoclines (ca. 0.8/sup 0/C 0.1 m/sup -1/) with temperatures below ca. 20/sup 0/C caused a marked decrease in swimming speed which resulted in accumulations of cells in these thermocline regions. Under conditions of nutrient sufficiency both algae migrated into the surface layers at irradiance values of over 1000 ..mu..E m/sup -2/s/sup -1/. Increasing nitrogen depletion caused the downward migration of both algae to commence progressively earlier in the day and before the end ...

1981-01-01

258

Experimental investigation of mixed convection heat transfer caused by forced-jets in large enclosure  

Energy Technology Data Exchange (ETDEWEB)

This research investigates experimentally mixed convection and heat transfer augmentation by forced jets in a large enclosure, at conditions simulating those of actual passive containment cooling systems and scales approaching those of actual containment buildings or compartments. The experiment was designed to measure the key parameters governing the heat transfer augmentation by forced jets and investigate the effects of geometric factors, including the jet diameter, jet injection orientation, interior structures, and enclosure aspect ratio. The tests cover a variety of injection modes leading to flow configurations of interest that contribute to reveal the nature of mixing and stratification phenomena in the containment under accident conditions of interest. The heat transfer of mixed convection can be predicted to be controlled by jet Archimedes number and geometric factors. Using a combining rule for mixed convection and appropriate forced and natural ...

2004-07-01

259

Effect of inhaled beclomethasone dipropionate on isocapnic hyperventilation with cold air in asthmatics, measured with forced oscillation technique.  

Science.gov (United States)

Isocapnic hyperventilation with cold air (IHCA) is a reliable technique for assessing indirect bronchial hyperresponsiveness in patients with asthma. Impedance measurement of the respiratory system by the forced pseudorandom noise oscillation technique is a sensitive technique to assess changes in bronchial tone after IHCA. The aim of this study was to evaluate the effect of 6 weeks of treatment with beclomethasone dipropionate, 1,000 microg x day-1, on IHCA in asthmatic patients, measured with both forced oscillation technique and flow-volume recordings. Forty patients with mild asthma were included in this double-blind, placebo-controlled parallel-group study. Stratification on the basis of sex was performed to overcome differences in airway diameter. At entry and every 2 weeks during the treatment period, IHCA was performed and patient diaries were evaluated. Characteristic changes in forced oscillation parameters after IHCA were observed in all patients. After ...

1997-03-01

260

Association of attention-deficit disorder and the dopamine transporter gene  

Energy Technology Data Exchange (ETDEWEB)

Attention-deficit hyperactivity disorder (ADHD) has been shown to be familial and heritable, in previous studies. As with most psychiatric disorders, examination of pedigrees has not revealed a consistent Mendelian mode of transmission. The response of ADHD patients to medications that inhibit the dopamine transporter, including methylphenidate, amphetamine, pemoline, and bupropion, led us to consider the dopamine transporter as a primary candidate gene for ADHD. To avoid effects of population stratification and to avoid the problem of classification of relatives with other psychiatric disorders as affected or unaffected, we used the haplotype-based haplotype relative risk (HHRR) method to test for association between a VNTR polymorphism at the dopamine transporter locus (DAT1) and DSM-III-R-diagnosed ADHD (N = 49) and undifferentiated attention-deficit disorder (UADD) (N = 8) in trios composed of father, mother, and affected offspring. HHRR analysis revealed ...

1995-04-01

261

Turbidimetric determination of sulfite ion in inhibited ethylene glycol-water solutions  

Science.gov (United States)

Turbidimetric method for determining sulfite in inhibited ethylene glycol-water solutions

1970-01-01

262
263

REPORT NO. 853  

Science.gov (United States)

water and of the ethylene glycol-water solutions are shown as functions of temperature in figures 4 and 5, respectively. (data from reference 4). ...

264

Process for reducing the water content of coal containing bound water  

Energy Technology Data Exchange (ETDEWEB)

An improved process is disclosed for reducing the water content of coal containing bound water by releasing at least a portion of the bound water by maintaining the coal at a temperature from about 220/sup 0/ to about 500/sup 0/ F. in the presence of water at a pressure sufficient to maintain at least portion of the water in a liquid phase for a time sufficient to release at least a portion of the bound water wherein the improvement comprises contacting the coal during such treatment with an active material selected from the group consisting of carboxylic organic acids containing up to about 6 carbon atoms, phenol, phenolic acids and inorganic acids.

1983-08-23

265

Implementation of the national desalination and water purification technology roadmap : structuring and directing the development of water supply solutions.  

Energy Technology Data Exchange (ETDEWEB)

In the United States, economic growth increasingly requires that greater volumes of freshwater be made available for new users, yet supplies of freshwater are already allocated to existing users. Currently, water for new users is made available through re-allocation of xisting water supplies-for example, by cities purchasing agricultural water rights. Water may also be made available through conservation efforts and, in some locales, through the development of ''new'' water from non-traditional sources such as the oceans, deep aquifer rackish groundwater, and water reuse.

2006-06-01

266

Energy and Water Conservation  

Science.gov (United States)

Jet Propulsion Laboratory. California Institute of Technology. Pasadena, California. Energy and Water Conservation. Steve Rigdon. Facilities Energy Manager ...

267

Combustible Water Repellent Coating.  

Science.gov (United States)

... Descriptors : *Combustible cartridge cases, *Water repellents, *Protective coatings, *Patents, Silica gel, Aluminum compounds, Binders ...

1973-07-24

268

Water chemistry and corrosion in water-steam circuits of nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

The water and steam circuits of steam generators in pressurized-water nuclear power plants are described together with the mechanism of denting, and the corrosion of spacer plates that leads to cracks in tubes by constriction. The different chemical specifications applicable to the water of the secondary circuit of the generators in normal operation and on first commissioning are listed. The results obtained and the measurements of chemical values taken in operation on the water in the secondary circuits of steam generators at Fessenheim and Bugey are presented.

1981-05-01

269

Water chemistry and corrosion in water-steam circuits of nuclear power plants  

International Nuclear Information System (INIS)

The water and steam circuits of steam generators in pressurized-water nuclear power plants are described together with the mechanism of denting, and the corrosion of spacer plates that leads to cracks in tubes by constriction. The different chemical specifications applicable to the water of the secondary circuit of the generators in normal operation and on first commissioning are listed. The results obtained and the measurements of chemical values taken in operation on the water in the secondary circuits of steam generators at Fessenheim and Bugey are presented.

270

Cooling facility for reactor container  

International Nuclear Information System (INIS)

Cooling water is sprayed on the outer surface of an upper portion of a container, and a pool is formed by the cooling water flowing down while cooling the container. Further, the cooling water stored in the cooling water pool is recycled by a pump for spraying the cooling water on the outer surface of the upper portion of the container. Sufficient amount of cooling water is supplied for spraying the cooling water to the outer surface of the upper portion of the container so that the outer surface of the container is free from drying and a liquid membrane is formed on the entire surface. The amount of the cooling water is made greater than that of the cooling water evaporated when the entire amount of the heat generate in the reactor core of the reactor is transferred to the cooling ...

1993-05-07

271

Water resources data for Texas, water year 1993. Volume 3. Colorado River basin, Lavaca River basin, Guadalupe River basin, Nueces River basin, Rio Grande basin, and intervening coastal basins. Water-data report (Annual), 1 October 1992-30 September 1993  

Energy Technology Data Exchange (ETDEWEB)

Water-resources data for the 1993 water year for Texas are presented in four volumes, and consist of records of stage, discharge, and water quality of streams and canals; and stage, contents, and water quality of lakes and reservoirs; and water levels and water quality of ground-water wells. Volume 3 contains records for water discharge at 134 gaging stations; stage only at 1 gaging stations; stage and contents at 13 lakes and reservoirs; water quality at 81 gaging stations; and data for 30 partial-record and 4 flood-hydrograph partial-record stations. Also included are lists of discontinued surface-water discharge or stage-only stations and discontinued surface-water-quality stations; crest-stage and flood-hydrograph partial-record stations, reconnaissance ...

1994-03-01

272

Interaction of water with epoxy.  

Energy Technology Data Exchange (ETDEWEB)

The chemistries of reactants, plasticizers, solvents and additives in an epoxy paint are discussed. Polyamide additives may play an important role in the absorption of molecular iodine by epoxy paints. It is recommended that the unsaturation of the polyamide additive in the epoxy cure be determined. Experimental studies of water absorption by epoxy resins are discussed. These studies show that absorption can disrupt hydrogen bonds among segments of the polymers and cause swelling of the polymer. The water absorption increases the diffusion coefficient of water within the polymer. Permanent damage to the polymer can result if water causes hydrolysis of ether linkages. Water desorption studies are recommended to ascertain how water absorption affects epoxy paint.

2009-07-01

273

European Commission - Environment  

Wastenet

...Species - see CITES Trade of Dangerous Chemicals Transport and Environment U Urban Environment Use of natural resources V Volatile Organic Compounds W Waste Landfills Waste electrical and electronic equipment - see WEEE Waste incineration Waste legislation - reporting Waste management planning Waste oils Waste shipments Waste water - see Urban waste water Water Bathing Water Drinking water Floods Marine environment Urban waste water Water Framework Directive WEEE - Waste Electric and Electronic Equipment Wildlife ...

274

The XMM-Newton wide-field survey in the COSMOS field. IV: X-ray spectral properties of Active Galactic Nuclei  

CERN Document Server

We present a detailed spectral analysis of point-like X-ray sources in the XMM-COSMOS field. Our sample of 135 sources only includes those that have more than 100 net counts in the 0.3-10 keV energy band and have been identified through optical spectroscopy. The majority of the sources are well described by a simple power-law model with either no absorption (76%) or a significant intrinsic, absorbing column (20%).As expected, the distribution of intrinsic absorbing column densities is markedly different between AGN with or without broad optical emission lines. We find within our sample four Type-2 QSOs candidates (L_X > 10^44 erg/s, N_H > 10^22 cm^-2), with a spectral energy distribution well reproduced by a composite Seyfert-2 spectrum, that demonstrates the strength of the wide field XMM/COSMOS survey to detect these rare and underrepresented sources.

2006-01-01

275

Preliminary studies of coolant by-pass flows in a prismatic very high temperature reactor using computational fluid dynamics  

Energy Technology Data Exchange (ETDEWEB)

Three dimensional computational fluid dynamic (CFD) calculations of a typical prismatic very high temperature gas-cooled reactor (VHTR) were conducted to investigate the influence of gap geometry on flow and temperature distributions in the reactor core using commercial CFD code FLUENT. Parametric calculations changing the gap width in a whole core length model of fuel and reflector columns were performed. The simulations show the effects of core by-pass flows in the heated core region by comparing results for several gap widths including zero gap width. The calculation results underline the importance of considering inter-column gap width for the evaluation of maximum fuel temperatures and temperature gradients in fuel blocks. In addition, it is shown that temperatures of core outlet flow from gaps and channels are strongly affected by the gap width of by-pass flow in the reactor core.

2009-09-01

276

On-line analysis of chemical composition using an FT-Raman spectrometer in the near-ir  

Science.gov (United States)

Newly commercialized Fourier transform Raman spectroscopic instrumentation provides a simpler alternative for vibrational spectroscopic analysis. Instrument vendors currently design for laboratory use, but there are many potential process applications of these stable, easy to use instruments. Raman spectroscopy is highly suited to analysis of aqueous samples. Near infrared excitation minimized fluorescence interference and allows for remote operation via fiber optic probes. The Department of Energy has funded research at the Measurement and Control Center to establish the utility of this method for on-line composition analysis in distillation columns. Laboratory evaluation and instrument employs an air-cooled laser and a thermoelectrically cooled detector. The device is mounted on a three by foot cart for convenient location in control rooms. Current fiber optic extension cables allow for analysis in a cell thirty five meters from the instrument. Application of the ...

1992-01-01

277

Numerical investigation of a bubble-column photo-bioreactor design for biodiesel production from microalgae  

Energy Technology Data Exchange (ETDEWEB)

Biodiesel made from vegetable oil is among the most desirable of renewable energy sources because it can be a substitute for diesel oil. However, biodiesel from soybean or corn can be confronted with a food crisis. Microalgae is a new biodiesel source which contains high oil lipids with a high growth rate, and which also offers value-added products from the residue, such as cosmetics, health functional food or pharmaceuticals. Microalgae are best cultivated in photo-bioreactors (PBRs) where light, nutrients, carbon dioxide and temperature can be controlled. Despite the current availability of PBRs, only a few can be practically used for mass production. Computational fluid dynamics (CFD) was used in this study to design an optimum bubble-column PBR for mass production of microalgae. Multi-phase models including bubble movement, meshes and time step independent tests were considered to develop the 3-dimensional CFD model. Particle Image Velocimetry (PIV) tests were ...

2010-07-01

278

Mercury-free fluorescent lighting  

Energy Technology Data Exchange (ETDEWEB)

A brief comparative review of possible mercury free fluorescent lighting technologies is presented, including rare-gas positive column discharges, molecular discharges, and dielectric barrier discharges. Detailed experimental results on xenon positive column discharges will then be considered. In order to judge whether xenon-based discharges are a viable UV source it is necessary to measure the radiant emittance (power per unit area) for the vacuum ultraviolet (VUV) resonance xenon emission at 147 nm. Two techniques to determine the VUV radiant emittance have been developed and applied to xenon discharges. One method combines the measured resonance level density using absorption spectroscopy and a calculation of the trapped decay rate for the resonance radiation to arrive at the radiant emittance at 147 nm. A second method utilizes a direct measurement of the radiance (power per unit area per unit solid angle) at 147 nm using a calibrated VUV ...

1996-05-01

279

Incorporation of Reaction Kinetics into a Multiphase, Hydrodynamic Model of a Fischer Tropsch Slurry Bubble Column Reactor  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the development of a computational multiphase fluid dynamics (CMFD) model of the Fischer Tropsch (FT) process in a Slurry Bubble Column Reactor (SBCR). The CMFD model is fundamentally based which allows it to be applied to different industrial processes and reactor geometries. The NPHASE CMFD solver [1] is used as the robust computational platform. Results from the CMFD model include gas distribution, species concentration profiles, and local temperatures within the SBCR. This type of model can provide valuable information for process design, operations and troubleshooting of FT plants. An ensemble-averaged, turbulent, multi-fluid solution algorithm for the multiphase, reacting flow with heat transfer was employed. Mechanistic models applicable to churn turbulent flow have been developed to provide a fundamentally based closure set for the equations. In this four-field model formulation, two of the fields are used to track the gas phase (i.e., ...

2008-11-01

280

Fluid dynamics of jet-forming elements of contact devices with directional gas stream injection  

International Nuclear Information System (INIS)

One way to intensify heat and mass transfer processes in column-type equipment is through use of contact devices with directional gas phase injection into a liquid. Making the perforations at an angle to the tray plane permits a rise in the permissible gas velocity in the column, since inertial force adds to gravity during separation. Different arrangements of the jet-forming elements relative to one another and to partitions and baffle-type contacts installed on the trays can improve phase contact conditions and intensify heat and mass transfer. Design of jet-type trays for a specific purpose requires that the influence of jet-forming, element design parameters on at least the fluid dynamic situation on the tray be known. In this work, the authors evaluate the influence of tab bend-up angle on jet tray working characteristics. These investigations demonstrate that the jet inclination angle (the angle of maximum gas velocity in the jet) exceeds ...

281

Effect of irradiation on bone remodelling and the structural integrity of the vertebral column. Doctoral thesis  

Energy Technology Data Exchange (ETDEWEB)

The effects of therapeutic levels of radiation on the axial properties of the primate vertebral column were studied. Seven male rhesus monkeys (Macaca mulatta) were irradiated with a single does of 1300 cGy to the specific lumbar vertebrae of L2, L3, and L4. Three additional animals served as controls. Radiographs were taken before the radiation treatment and just prior to sacrifice to determine density changes in the bone. The animal subjects were sacrificed 105 days following the radiation exposure. Biomechanical testing was completed on lumbar levels 2 and 3 to identify changes in strength characteristics following radiation treatment. Histomorphometric analysis of lumbar vertebrae level 4 was completed to identify volume and surface density changes as well as cellular changes. Tetracycline, dicarbomethylaminomethyl fluorescein (DCAF), and xylenol orange were used as bone labeling agents to aid in the histomorphometry and to obtain dynamic parameter changes.

1990-01-01

282

Determination of 40 synthetic food colors in drinks and candies by high-performance liquid chromatography using a short column with photodiode array detection  

British Library Electronic Table of Contents (United Kingdom)

Forty synthetic food colors were determined in drinks and candies by reversed-phase high-performance liquid chromatography with photodiode array detection. The following food colors were analyzed within 19min using a short analytical column (50mmx4.6mm i.d., 1.8mm) at 50degreeC with gradient elution: Ponceau 6R, Tartrazine, Fast yellow AB, Amaranth, Indigotine, Naphthol yellow S, Chrysoine, Ponceau 4R, Sunset yellow FCF, Red 10B, Orange G, Acid violet 7, Brilliant black PN, Allura red AC, Yellow 2G, Red 2G, Uranine, Fast red E, Green S, Ponceau 2R, Azorubine, Orange I, Quinoline yellow, Martius yellow, Ponceau SX, Ponceau 3R, Fast green FCF, Eosine, Brilliant blue FCF, Orange II, Orange RN, Acid blue 1, Erythrosine, Amido black 10B, Acid red 52, Patent blue V, Acid green 9, Phloxine B, Ben...

2008-01-01

283

Design experience of the JRR-2 BNCT facility in JAERI  

Energy Technology Data Exchange (ETDEWEB)

The thermal neutron column of the JRR-2 reactor was remodelled in order to install a medical irradiation facility. The design experience and the cource of this remodelling are presented. At first, the thermal neutron flux was lower than expected, and the expected radiation condition was achieved by the following improvements: (1) removal of graphite from the thermal neutron column to increase the neutron flux, (2) twice increase of bismuth shielding and the shift of its position to improve the shielding effect against gamma ray, (3) application of B{sub 4}C rubber on the both surfaces of the shielding door to suppress the secondary gamma ray generation from the structural materials, (4) LiF tiles are applied on the inner face of the neutron beam exit hole to suppress the secondary gamma ray from the beam exit, and (5) installment a cone-shape polyethylene collimator to relieve the decay of thermal neutron. After the improvements, medical ...

1994-06-01

284

Characterization of 3D thermal neutron semiconductor detectors  

International Nuclear Information System (INIS)

Neutron semiconductor detectors for neutron counting and neutron radiography have an increasing importance. Simple silicon neutron detectors are combination of a planar diode with a layer of an appropriate neutron converter such as 6LiF. These devices have limited detection efficiency of not more than 5%. The detection efficiency can be increased by creating a 3D microstructure of dips, trenches or pores in the detector and filling it with a neutron converter. The first results related to the development of such devices are presented. Silicon detectors were fabricated with pyramidal dips on the surface covered with 6LiF and then irradiated by thermal neutrons. Pulse height spectra of the energy deposited in the sensitive volume were compared with simulations. The detection efficiency of these devices was about 6.3%. Samples with different column sizes were fabricated to study the electrical properties of 3D structures. Charge collection efficiencies in silicon ...

2007-06-11

285

Characterisation of polynuclear aromatic sulfur-heterocycles in a coal extract by GC/MS  

Energy Technology Data Exchange (ETDEWEB)

Polynuclear aromatic sulphur heterocycles (PASHs) were isolated from a coal extract by two-step separation method using silica gel column chromatography and ligand exchanges thin layer chromatography (PdCl{sub 2}/SiO{sub 2}). The subfraction was examined by capillary column gas chromatography with flame ionization detector and flame photometric detector and gas chromatography - mass spectrometry. Identification was accomplished by comparison of chromatographic retention indices and mass spectra of compounds with those reported in the literature. It was found that the principal structures of the sulphur-containing fraction of Guiding coal extract have 3-4 aromatic rings. Dibenzothiophene, C{sub 1} - C{sub 3} alkylated dibenzothiophenes, benzonaphthothiophene and its alkylated derivatives were the main compounds. Only a few other polynuclear sulfur heterocycles were detected. No benzothiophene and its derivatives were presented. 8 refs., 2 figs., ...

1994-06-01

286

Biosorption of heavy metals from wastewater by biosolids  

Energy Technology Data Exchange (ETDEWEB)

In a study where the removal of heavy metals from wastewater is the primary aim, the biosorption of heavy metals onto biosolids prepared as Pseudomonas aeruginosa immobilized onto granular activated carbon was investigated in batch and column systems. In the batch system, adsorption equilibriums of heavy metals were reached between 20 and 50 min, and the optimal dosage of biosolids was 0.3 g/L. The biosorption efficiencies were 84, 80, 79, 59 and 42 % for Cr(VI), Ni(II), Cu(II), Zn(II) and Cd(II) ions, respectively. The rate constants of biosorption and pore diffusion of heavy metals were 0.013-0.089 min{sup -1} and 0.026-0.690 min{sup -0.5}. In the column systems, the biosorption efficiencies for all heavy metals increased up to 81-100 %. The affinity of biosorption for various metal ions towards biosolids was decreased in the order: Cr = Ni > Cu > Zn > Cd. (Abstract Copyright [2006], Wiley Periodicals, Inc.)

2006-08-15

287

Anisotropic magnetism in hybridizing uranium systems  

International Nuclear Information System (INIS)

The isostructural uranium monopnictides and monochalcogenides have become prototype systems in actinide research with respect to their unusual magnetic properties. We have investigated the origins in the electronic structure of the variation in magnetic behavior as the degree of 5f-electron localization changes from localized to itinerant on going up the pnictogen or chalcogen column, thus decreasing the U-U separation. We have applied a synthesis of: (1) A phenomenological theory of orbitally driven magnetic ordering which includes both the hybridization-induced and the RKKY exchange interactions on an equal footing, and (2) Ab initio electronic structure calculations, based on the linear-muffin-tin-orbital method, allowing a first-principles evaluation of the parameters entering the model Hamiltonian. We have investigated systematically characteristic trends and changes of the 5f-state resonance width, the hybridization potential, and the hybridization-induced ...

288

A simple model for strontium breakthrough on zeolite columns  

Science.gov (United States)

The Process Waste Treatment Plant (PWTP) at the Oak Ridge National Laboratory is designed to remove radioactive contaminants, principally {sup 90}Sr, from process wastewater. Planned upgrades to the PWTP will use chabazite zeolite columns. Pilot-scale studies have shown that mass transfer zone lengths increase from 10 to about 30 cm as the superficial velocity increases from 5.5 to 22 cm/min. Calculations with a multicomponent equilibrium model showed that the distribution coefficient for strontium remains essentially constant over the process conditions, suggesting that a simple kinetic model (the Rosen long-bed solution) should adequately represent breakthrough behavior. Using a distribution coefficient of 4.87 L/g predicted by the equilibrium model, good agreement was found between experimental breakthrough curves and those calculated with the Rosen solution. This model allows prediction of bed depths and cycle times necessary to achieve the required ...

1995-04-01

289

Wastewater treatment of industrial effluent using activated dolomite adsorption  

Environmental Research Database

SummaryInitial results from the use of activated dolomite from QUESTOR project L1 have proved extremely encouraging in terms of metallic ion (also phosphate, nitrate and dye) removal from wastewater, with capacities in some instances in excess of commercially available activated carbons.This new project involves investigating actual plant effluent in laboratory scale columns and the design of a pilot scale rig for on site trials. The project also involves investigating disposal options and an economic [continued...

2007-01-01

290

Various approximations made in augmented-plane-wave calculations  

Energy Technology Data Exchange (ETDEWEB)

The effects of various approximations used in performing augmented-plane-wave calculations were studied for elements of the fifth and sixth columns of the Periodic Table, namely V, Nb, Ta, Cr, Mo, and W. Two kinds of approximations have been checked: (i) variation of the number of k points used to iterate to self-consistency, and (ii) approximations for the treatment of the core states. In addition a comparison between relativistic and nonrelativistic calculations is made, and an approximate method of calculating the spin-orbit splitting is given.

1985-10-15

291

Various approximations made in augmented-plane-wave calculations  

International Nuclear Information System (INIS)

The effects of various approximations used in performing augmented-plane-wave calculations were studied for elements of the fifth and sixth columns of the Periodic Table, namely V, Nb, Ta, Cr, Mo, and W. Two kinds of approximations have been checked: (i) variation of the number of k points used to iterate to self-consistency, and (ii) approximations for the treatment of the core states. In addition a comparison between relativistic and nonrelativistic calculations is made, and an approximate method of calculating the spin-orbit splitting is given.

292

Study on the use of zirconium phosphate for radioactive waste treatment  

International Nuclear Information System (INIS)

Zirconium phosphate was one of the earliest inorganic ion-exchange suggested for removing strontium and cesium from aqueous nuclear waste. This paper studied ionic exchange to remove Cs-137 and Sr-90 by using different cationic of zirconium phosphate. In this case the parameters studied were the effect of temperature and ion concentration to percent up take and distribution coefficients. It is also conducted the study on column experiments to determine the breakthrough curves for Cs-137 and Sr-90. The result showed the potential of use of zirconium phosphate in radioactive waste treatment. (author)

1998-12-01

293

Spreadsheet determines hyperbolic-decline parameters  

Energy Technology Data Exchange (ETDEWEB)

Production decline-curve analysis is accepted for prediction of future performance of oil and gas wells and fields. One type of decline-curve analysis involves the hyperbolic-decline-curve equation. The challenge with this equation is to determine simultaneously three parameters. The new method creates a computer spreadsheet containing a set of production data. Then, the specific arrangement of cells and columns containing data and/or formulas allows for statistical fits of the data. Finally, setting-up the nonlinear solver allows for optimization of the three parameters by maximization of the square of the regression coefficient. Eight field cases demonstrated the repeatable and rapid curve-fitting of the method.

1994-03-14

294

Separation of platinum group metal ions by Donnan dialysis  

Energy Technology Data Exchange (ETDEWEB)

Separations of metal ions on the basis of Donnan dialysis across anion-exchange membranes should be possible if the receiver electrolyte composition favors the formation of selected anionic complexes of the sample metal ions. Moreover, such a separation has the possibility of being better suited from some applications than batch or column experiments with anion-exchange resins. The above hypothesis are tested on the platinum-group metal ions, Pt(IV), Rh(III), Pd(II), Ir(III), and Ir(IV). 13 references, 4 tables.

1985-10-01

295

Separation of lithium isotopes by counter-current flow of the coexisting phases of a lithium-ammonia solution  

Energy Technology Data Exchange (ETDEWEB)

A weak shift of the isotope concentration ratio Li{sup 6}/Li{sup 7} was measured in the coexisting phases of the miscibility gap of lithium-ammonia solutions. Li{sup 6} is slightly enriched in the concentrated metallic phase (enrichment factor {alpha} = 1.009 {+-} 0.002). This effect can be enhanced in a counter-current column to yield any desired enrichment of the two isotopes. The counter current system and its operation were tested succesfully with a sodium-potassium-ammonia solution.

1991-12-01

296

Prospects for lithium imaging using annular bright field scanning transmission electron microscopy: A theoretical study  

British Library Electronic Table of Contents (United Kingdom)

There is strong interest in lithium imaging, particularly because of its significance in battery materials. However, light atoms only scatter electrons weakly and atomic resolution direct imaging of lithium has proven difficult. This paper explores theoretically the conditions under which lithium columns can be expected to be directly visible using annular bright field scanning transmission electron microscopy. A detailed discussion is given of the controllable parameters and the conditions most favourable for lithium imaging.

2011-01-01

297

Possibility of internal transport barrier formation and electric field bifurcation in LHD plasma  

Energy Technology Data Exchange (ETDEWEB)

Theoretical analysis of the electric field bifurcation is made for the LHD plasma. For given shapes of plasma profiles, a region of bifurcation is obtained in a space of the plasma parameters. In this region of plasma parameters, the electric field domain interface is predicted to appear in the plasma column. The reduction of turbulent transport is expected to occur in the vicinity of the interface, inducing a internal transport barrier. Within this simple model, the plasma with internal barriers is predicted to be realized for the parameters of T{sub e}(0) {approx} 2 keV and n(0) {approx_equal} 10{sup 18} m{sup -3}. (author)

1999-05-01

298

Physical phenomena in Z-pinch plasma of impulse plasma deposition process  

International Nuclear Information System (INIS)

In the present paper we propose a model of physical phenomena behind the front face of the electrodes in an impulse plasma accelerator. The model is based on the results of recent experimental observations and measurements. It correlates plasma dynamics with mechanism of phenomena in a column of pinching plasma. On the contrary to the previous model the current one suggests the series of relatively short pulses of metallic ions from the erosion of electrode material. Till now the pinch was treated rather as a nearly continuous source of metallic plasma, feeding the process with ions from the erosion of electrode material. (author)

2001-09-23

299

Novel approach towards improving decontamination factor (DF) in treatment of low level radioactive waste  

International Nuclear Information System (INIS)

The use of finely powdered ion exchange resins improve loading of specific ion exchange materials with better performance but as such these materials are not suitable for column operation. However, by proper selection of ion exchange support medium, it is possible to get better product. The radioactive solution can be treated by suspending this material, stirring and allowing to settle. The present method gives DF in the range of 70 - 80 even after repeated use as compared to DF in the range of 5 to 10 by single conventional chemical treatment process. (author)

2001-02-07

300

Mineral biotechnology. Microbial aspects of mineral beneficiation, metal extraction, and environmental control  

Energy Technology Data Exchange (ETDEWEB)

Papers in this book illustrate the utility of mineral biotechnology with respect to biobeneficiation, bioleaching, bioremediation and biomineralization. Papers of particular interest to the coal industry include: depression of pyrite flotation by yeast and bacteris (S.K. Kawatra and T.C. Eisele); desulfurization of coal by microbial flotation in a semicontinuous system (T. Nagaoka and others); biochemical removal of HAP precursors from coal - INEEL slurry column testing (K.S. Noah and G.J. Olson); microorganisms, biotechnology and acid rock drainage - emphasis on passive-biological control and treatment methods (N. Kuyucak); and utility of bioreagents in mineral processing (P. Somasundaran and others).

2001-07-01

301

Isolation and amino acid sequence of a short-chain neurotoxin from an Australian elapid snake, Pseudechis australis.  

Science.gov (United States)

A short-chain neurotoxin Pseudechis australis a (toxin Pa a) was isolated from the venom of an Australian elapid snake Pseudechis australis (king brown snake) by sequential chromatography on CM-cellulose, Sephadex G-50 and CM-cellulose columns. Toxin Pa a has an LD50 (intravenous) value of 76 micrograms/kg body wt. in mice and consists of 62 amino acid residues. The amino acid sequence of Pa a shows considerable homology with those of short-chain neurotoxins of elapid snakes, especially of true sea snakes. PMID:4091794

1985-12-01

302

In situ observation of axial irradiation growth in liquid-metal reactor metal fuel  

International Nuclear Information System (INIS)

Effects of the rapid early-in-life expansion of metal fuel were measured in an irradiation experiment in the Fast Flux Test Facility (FFTF). This important performance/design information was obtainable through the unique combination of a dimensionally stable FFTF oxide core and the calibrated proximity instrumentation associated with the test. These results delineate the time dependence of metal-fuel swelling and provide quantitative estimates of the magnitude of axial fuel swelling in full-length metal-fuel assemblies. Final posttest examination results will define actual fuel column growth levels.

1989-11-26

303

Improvement of muscle strenght independently of analgesic effect following spinal cord stimulation. A case report.  

Science.gov (United States)

Spinal cord stimulation (SCS) is frequently used for relief of chronic benign pain resistant to conservative therapies. Clinical practice suggests, at least in patients with failed back surgery syndrome (FBSS), the possibility that SCS significantly improves motor performances. We present here the case of a 41-years-old female patient with FBSS, who showed a clear improvement in muscle strength after SCS, persisting at 6-months follow-up. We speculate that the electrical stimulation of posterior columns could potentiate the caudal, segmental spinal reflexes resulting in a facilitation of motoneurons activation. PMID:16175150

2004-12-01

304

Desorption of CO{sub 2} from MDEA and activated MDEA solutions  

Energy Technology Data Exchange (ETDEWEB)

A packed column was used for investigating the desorption rate of CO{sub 2} from aqueous methyldiethanolamine (MDEA) and activated MDEA solutions. Experiments were conducted within the temperature range 30--70 C, the concentration of MDEA was 4.28 kmol/m{sup 3}, and the concentration of piperazine (PZ) was 0.10 kmol/m{sup 3} for aqueous activated MDEA solutions. Experimental data confirmed that the kinetics model of absorption CO{sub 2} into aqueous MDEA and activated MDEA solutions can be applicable to the situations in which desorption occurs, and the desorption rate of model predictions agree well with that of experimental determination.

1995-03-01

305

Asymptotic estimates for the number of solutions of the dualization problem and its generalizations  

British Library Electronic Table of Contents (United Kingdom)

Asymptotic estimates for the typical number of irreducible coverings and the typical length of an irreducible covering of a Boolean matrix are obtained in the case when the number of rows is no less than the number of columns. As a consequence, asymptotic estimates are obtained for the typical number of maximal conjunctions and the typical rank of a maximal conjunction of a monotone Boolean function of variables defined by a conjunctive normal form of clauses. Similar estimates are given for the number of irredundant coverings and the length of an irredundant covering of an integer matrix (for the number of maximal conjunctions and the rank of a maximal conjunction of a two-valued logical function defined by its zero set). Results obtained previously in this area are overviewed.

2011-01-01

306

A simplified approach to the drying of solids in a batch fluidised bed  

Scientific Electronic Library Online (English)

Abstract in english A simplified model for drying solids in the constant rate period in a batch fluidised bed was developed.It assumes the bed to be divided into dense and bubble phases with heat and mass transfer between the phases.The model predicts the constant-rate drying period, provided the fluid bed shape and material characteristics are known.The model is compared with experimental data reported in the literature covering a wide range of materials, gas flow rates, column diameters, m (more) aterial hold-ups, air temperatures and humidities.Model predictions compare satisfactorily with the experimental data.

2002-07-01

307

Phosphorus and nitrogen in the eutrophication of waters. Fosfori ja typpi vesien rehevoeittaejinae - vaikutusten arviointi  

Energy Technology Data Exchange (ETDEWEB)

This report is a summary of the contribution of nitrogen and phosphorus in the eutrophication process of inland and coastal waters. Special attention was paid to the mechanisms of these nutrients in regulating biological processes and to the methods available in estimating their effects in the eutrophication of water bodies. The report includes five chapters which are entitled: Introduction, which is a general background to the subject with special attention to the requirements of the Finnish Water Act. Phosphorus and nitrogen as factors regulating biological processes. The topics included are: definition of eutrophication, forms of phosphorus and nitrogen and their sources to inland and coastal waters, effects of these nutrients as growth factors of phytoplankton and macrophytes and consequences of eutrophication. Estimation of the effects of phosphorus and nitrogen. The topics discussed from the point ...

1992-01-01

308

Formulation and make-up of simulate dilute water, low ionic content aqueous solution  

Energy Technology Data Exchange (ETDEWEB)

This procedure describes the formulation and make-up of Simulated Dilute Water (SOW), a low-ionic-content water to be used for Activity E-20-50, Long-Term Corrosion Studies. This water has an ionic content which is nominally a factor of ten higher than that of representative waters at or near Yucca Mountain. Representative waters were chosen as J-13 well water [Harrar, 1990] and perched water at Yucca Mountain [Glassley, 1996]. J-13 well water is obtained from ground water that is in contact with the Topopah Spring tuff, which is the repository horizon rock. The perched water is located in the Topopah Spring tuff, but below the repository horizon and above the water table. A nominal times ten higher ionic content was chosen to simulate the effect of ionic ...

1997-04-04

309

On-farm water management in saline groundwater area under scarce canal water supply condition in the Northwest India  

British Library Electronic Table of Contents (United Kingdom)

The study investigates the possibility of enhancing crop water productivity in the parts of Northwest India where groundwater quality is marginal and canal water supply is severely scarce. Soil, Water, Atmosphere and Plant (SWAP) model was calibrated and validated in three farmers' fields with varying canal water availability and groundwater quality in the Kaithal Irrigation Circle of the Bhakra Canal system, Haryana. On the basis of predicted and observed soil water content, pressure heads, salt concentration at 2 week intervals and crop yields, the model was found suitable for use in the region. A few nomographs were prepared to provide a graphical method to predict the effect of different combinations of water quality and depth of water application on crop yield and soil salinity and to...

2008-01-01

310

Major roles of water chemistry for safe and reliable nuclear power plant operation. Research committee on water chemistry standard  

International Nuclear Information System (INIS)

The research committee of the Atomic Energy Society of Japan on water chemistry standard aims at establishing the private standard of water chemistry of nuclear power plants. The committee gathers up 'BWR water chemistry management manual', 'PWR primary system water chemistry management manual' and 'PWR water chemical analysis standard method', and furthermore aims at the standardization of those in future. Looking back on the committee's activities for the past four years, latest results of research of water chemistry mainly contributing to safe and reliable nuclear power plants were described with the future perspective of water chemistry and a demanded break-through. (T.T.)

2007-05-01

311

Laser-fluorescence determination of trace uranium in hot spring water, geothermal water and tap water in Xi'an Lishan region  

International Nuclear Information System (INIS)

Using the Laser-Fluorescence technique, an investigation was made, adopting the standard mix method, on trace uranium concentrations in hot spring water and geothermal water from Lishan region, and in tap water from some major cities in Shanxi province. Totally 40 samples from 27 sites were investigated. Measurement showed that the tap water contains around 10"-"6 g/L of uranium, whose concentrations in both hot spring water and geothermal water are 10"-"5 g/L. Most of samples are at normal radioactive background level, some higher contents were determined in a few samples

2002-03-01

312

Corrosion behavior of iron and nickel base alloys in high temperature and pressure water  

International Nuclear Information System (INIS)

In equipment industries, the equipments handling industrial water and pure water are numerous. In power generation including nuclear power generation, water serves as a working medium. Review is made on the experiences in the corrosion of iron and nickel base alloys in high temperature, high pressure water and the results of researches derived from them. Under high temperature and high pressure, carbon steel, low alloy steel, stainless steel and high nickel alloy cause corrosion even in pure water. But in the case of serious corrosion, chlorine, oxygen, alkali and others in water take part. The following matters are described: corrosion by steam; stress corrosion cracking in pure water; corrosion by impurities in high temperature, high pressure pure water, i.e. chlorine ions, dissolved oxygen, and alkali; corrosion under ...

313

AquaMagna Water Conditioner and Descaler  

Wastenet

...AquaMagna Water Conditioner and Descaler OCETA Environmental Technology & Business Profiles AQUAMAGNA WATER CONDITIONER AND DESCALER CAT. #03-018 CONTACT: Magna-Tek ...removal high-strength ceramic magnet no energy input The AquaMagna Water Conditioner and Descaler is a non-chemical method of water treatment. The technology uses ... Figure 1: The AquaMagna Water Conditioner and Descaler PROCESS/ PRODUCT APPLICATION: hard water domestic water process water reverse osmosis heat exchangers cooling ... For once-through or recirculating heating or cooling equipment, the AquaMagna descaler improves thermal efficiencies and reduces downtime. Figure 2 illustrates a cross-section ...

314

A novel domestic electric water heater model for a multi-objective demand side management program  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a novel domestic hot water heater model to be used in a multi-objective demand side management program. The model incorporates both the thermal losses and the water usage to determine the temperature of the water in the tank. Water heater loads are extracted from household load data and then used to determine the household water usage patterns. The benefits of the model are: (1) the on/off state of the water heater and temperature of the water in the tank can be accurately predicted, and (2) it enables the development of water usage profiles so that users can be classified based on usage behaviour. As a result, the amount of ancillary services and peak shaving that can be achieved are accurately predictable and can be maximized without adversely affecting users. (author)

2010-12-15

315

Use of receptor affinity chromatography in purification of the growth hormone-like factor produced by plerocercoids of the tapeworm Spirometra mansonoides.  

Science.gov (United States)

The plerocercoid stage of the tapeworm Spirometra mansonoides produces a functional analog of human growth hormone (hGH). Among the similarities between plerocercoid growth factor (PGF) and hGH is competition for the same receptors on rabbit liver membranes. To take advantage of this characteristic in a purification scheme for PGF, rabbit liver microsomes were solubilized in Triton X-100 and the hGH receptors were purified over an hGH affinity column. The purified receptors from six rabbit livers were coupled to Affi-Gel-10 to create a receptor affinity column which was used to purify PGF. Chromatography of crude PGF over the receptor column resulted in a 1044 fold increase in specific activity. SDS-PAGE in the presence of 2-mercaptoethanol showed that the affinity-purified PGF contained three protein bands with apparent Mrs of 27.5 K, 22 K, and 16.7 K. Injections of the partially-purified PGF into hypophysectomized rats ...

1988-01-01

316

The Two-Column Aerosol Project (TCAP) Science Plan  

Energy Technology Data Exchange (ETDEWEB)

The Two-Column Aerosol Project (TCAP) field campaign will provide a detailed set of observations with which to (1) perform radiative and cloud condensation nuclei (CCN) closure studies, (2) evaluate a new retrieval algorithm for aerosol optical depth (AOD) in the presence of clouds using passive remote sensing, (3) extend a previously developed technique to investigate aerosol indirect effects, and (4) evaluate the performance of a detailed regional-scale model and a more parameterized global-scale model in simulating particle activation and AOD associated with the aging of anthropogenic aerosols. To meet these science objectives, the Atmospheric Radiation Measurement (ARM) Climate Research Facility will deploy the ARM Mobile Facility (AMF) and the Mobile Aerosol Observing System (MAOS) on Cape Cod, Massachusetts, for a 12-month period starting in the summer of 2012 in order to quantify aerosol properties, radiation, and cloud characteristics at a location subject ...

2011-07-27

317

Radiant emittance of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

An embodiment of a mercury-free fluorescent lamp combines a low pressure rare gas discharges with a phosphor having a quantum efficiency grater than one. The choice of the rare gas depends on a number of factors, one of which is the resonance transition energy. Less demand is placed the quantum efficiency of the phosphor for a lower energy resonance photon. Xenon has the lowest energy resonance transition of the stable rare gases at 8.5 eV (147 nm) and thus is a good candidate to study. The usefulness of a xenon-based discharge depends on the radiant emittance of the discharge at the resonance wavelength of 147 nm. The radiant emittance from a low pressure xenon positive column discharge is measured using two independent techniques. The first relies on the measurement of the resonance level density using absorption techniques. The effective decay rate of the resonance level is calculated using radiation trapping theory. The product of this density and trapped decay ...

1994-12-31

318

Preparation and biodistribution of yttrium-90 lipiodol in rats following hepatic arterial injection  

Energy Technology Data Exchange (ETDEWEB)

We labelled Lipiodol with yttrium-90 and analysed the biodistribution in rats after intrahepatic arterial injection. An RP-18 column was used to separate {sup 90}Y from strontium-90. {sup 90}Y was retained on the column, which had been pretreated with yttrium-selective extraction reagent, di(2-ethylhexyl) phosphate, while {sup 90}Sr was washed out. A hexadentate nitrogen-donor chelating ligand N,N,N`,N`-tetrakis(2-benzymidazolylmethyl)-1,2-ethanediamine (EDTB) was synthesized by condensation of 1,2-benzenediamine and ethylene diamine tetra-acetic acid (EDTA). Lipiodol was covalently conjugated with EDTB. The final product was obtained by eluting the retained {sup 90}Y from the RP-18 column with EDTB-Lipiodol. Sixteen male rats (Sprague-Dawley) were sacrificed at 1 h, 24 h, 48 h and 72 h (four rats at each time) after injection of approximately 0.1 mCi {sup 90}Y-Lipiodol via the hepatic artery. Samples of liver, spleen, ...

1995-03-01

319

Determination of Cinchona alkaloids and Vitamin B_6 by high-performance liquid chromatography with fluorescence detection  

International Nuclear Information System (INIS)

A simple and specific method has been developed for the simultaneous determination of the four major Cinchona alkaloids and their dihydroderivatives and pyridoxine hydrochloride (Vitamin B_6) by high-performance liquid chromatography (HPLC) with fluorescence detection (#lambda#_e_m=420 nm with #lambda#_e_x=330 nm). The chromatographic separation was performed on a Phenomenex Prodigy ODS column (5 #mu#m, 250 mmx3.2 mm i.d.), recommended for basic compounds, under isocratic reversed-phase conditions. The method allowed a good peak shape and an effective resolution of the tested compounds. The extraction of alkaloids from the Cinchona succirubra bark was carried out in mild and fast conditions (ambient temperature, 20 min) by ultrasonication. The procedure showed to be advantageous respect to a reference method, which involved Soxhlet extraction. The results were compared statistically by means of the Student's t-test and the variance ratio F-test; no significant ...

2004-06-04

320

CO_2 reactivity and heterogeneity of cerebral blood flow in ischemic, border zone, and normal cortex  

International Nuclear Information System (INIS)

Regional arterial CO2 tension (PaCO2) reactivity of cerebral blood flow (CBF) and the effect of PaCO2 on the spatial and temporal heterogeneity of CBF were investigated by using autoradiographically determined CBF in the rat middle cerebral artery occlusion model after a 2-h period under pentobarbital anesthesia to clarify the relation between PaCO2 reactivity, CBF heterogeneity, and the temporal cycling of CBF. PaCO2 was adjusted to one of four levels. CBF was determined in four cortical areas and white matter using the tissue fractionation of [14C]iodoantipyrine [( 14C]IAP) in combination with vessel mapping using in vivo 4% thioflavine S. Specific PaCO2 reactivity and CBF were normal in the nonischemic cortex, normal, although slightly depressed, in the border zone far from the ischemic core area, and depressed in the border zone adjacent to the ischemic core area (P less than 0.001) and the ischemic core (P less than 0.001). In normocapnic and hypocapnic animals, CBF heterogeneity ...

321

Aliphatic acids: influence on sulfate mobility in a forested Cecil soil  

Science.gov (United States)

Dissolved organic substances derived from forest litter are believed to influence the retention and movement of SO{sub 4}{sup 2{minus}} in forest soils. A column study was conducted in which {sup 35}SO{sub 4} was surface applied to a soil and leached with either low-molecular-weight aliphatic acids (AA) or a forest-litter extract. Oxalic, malonic, and succinic acids were used in the concentration range 8.0 {times} 10{sup {minus}3} to 1.0 {times} 10{sup {minus}5} mol L{sup {minus}1}. Movement of {sup 35}SO{sub 4} was determined with column depth, as was the {sup 35}SO{sub 4} activity in the collected leachates. Labeled SO{sub 4} soil movement was found to increase with increasing AA concentration. Leachate {sup 35}SO{sub 4} activity was observed to increase in the order malonic > succinic > oxalic for acid treatments > 1.0 {times} 10{sup {minus}4} mol L{sup {minus}1}. The 1.0 {times} 10{sup {minus}5} mol L{sup {minus}1} acid treatments ...

322

Water | Editorial Board  

Wastenet

...Tota-MaharajE-Mail: Interests: water and wastewater treatment, environmental engineering and sustainable systems; sustainable water management; sustainable urban drainage systems (SUDS); combined renewable energy applications with reverse osmosis desalination; microbial fuel cells for bioenergy production and treatment of urban wastewater; solar photocatalytic treatment and disinfection of water/wastewater Dr. Simon Toze CSIRO Land and Water, Queensland Bioscience Precinct - St Lucia, 306 Carmody Road, St Lucia QLD 4067,...

323

Changes in water dependence of Russian economy  

British Library Electronic Table of Contents (United Kingdom)

Indicators of source water use in different economic branches, water consumption in recycling and recycling-successive water supply in 1980?2006 are analyzed. Trends were identified in variations in specific water consumption in industry, agriculture, and municipal economy. Territorial differentiation of wetness indicators of regional product over federal districts and constituent territories of the RF is shown. Wetness values of gross domestic product in different economies are compared.

2010-01-01

324

Interpretation of data obtained from non-destructive and destructive post-test analyses of an intact-core column of culebra dolomite  

Energy Technology Data Exchange (ETDEWEB)

The U.S. Department of Energy (DOE) has been developing a nuclear waste disposal facility, the Waste Isolation Pilot Plant (WIPP), located approximately 42 km east of Carlsbad, New Mexico. The WIPP is designed to demonstrate the safe disposal of transuranic wastes produced by the defense nuclear-weapons program. Pefiormance assessment analyses (U.S. DOE, 1996) indicate that human intrusion by inadvertent and intermittent drilling for resources provide the only credible mechanisms for significant releases of radionuclides horn the disposal system. These releases may occur by five mechanisms: (1) cuttings, (2) cavings, (3) spallings, (4) direct brine releases, and (5) long- term brine releases. The first four mechanisms could result in immediate release of contaminant to the accessible environment. For the last mechanisq migration pathways through the permeable layers of rock above the Salado are important, and major emphasis is placed on the Culebra Member of the Rustler Formation ...

1998-09-01

325

USGS Arkansas Water Science Center  

Science.gov (United States)

number Fax (501) 228-3600 (501) 228-3601 Surface Water Data Information Requests Bill Baldwin (501) 228-3602 Surface Water General Information Jaysson Funkhouser (501) 228-3663...

2011-09-23

326

The BEACHES Study: health effects and exposures from non-point source microbial contaminants in subtropical recreational marine waters  

UK PubMed Central (United Kingdom)

Background Microbial water-quality indicators, in high concentrations in sewage, are used to determine whether water is safe for recreational purposes. Recently, the use of these indicators...Full Text Available

2010-10-01

327

Study on the separation characteristics of tritiated water vapor adsorption.  

Science.gov (United States)

In order to reduce the air concentration of (sup 3)H in the reactor buiIding of Wolsung Heavy Water Reactor, a computer code for estimation of adsorption behavior was programmed based on an equation derived for analysis of water vapor adsorption, and a ba...

1991-01-01

328

Rational protection of the quality of coastal waters by means of integrated, real-time management of the water environment; Proteccion racional de la calidad de las aguas costeras mediante la gestion integrada y en tiempo real del medio hidrico  

Energy Technology Data Exchange (ETDEWEB)

Before the implementation Water Framework directive, it was usual to forget that a good environment protection of the receiving waters needs a correct and coordinated operation of the subsystems of the water cycle, specially sewerage system, WWTP and receiving waters. This explains that most of the countries have focused their efforts in the treatment of dry weather flows forgetting the management of wet weather flows. Actually the idea that a sewerage system or a WWTP can not be planned or managed independently without considering the effects on the receiving waters is commonly accepted because not only each one of these systems must work correctly but also it is required a minimum impact in the receiving waters of the sewerage and WWTP overflows in dry and wet weather. All these links will affect the management strategy of the sewerage system (storm ...

2005-07-01

329

On the water-chemical regime in steam generators at NPP  

British Library Electronic Table of Contents (United Kingdom)

The effect of the water-chemical regime (WCR) on damage sustained by heating surfaces of steam generators at NPP is analyzed. It is indicated that phosphate treatment with minimal excesses of phosphates in the steamgenerator water is the most optimal method of managing the WCR regime of horizontal steam generators.

2006-01-01

330

Nodule and Leaf Nitrate Reductases and Nitrogen Fixation in Medicago sativa L. under Water Stress  

UK PubMed Central (United Kingdom)

The effect of water stress on patterns of nitrate reductase activity in the leaves and nodules and on nitrogen fixation were investigated in Medicago sativa L. plants watered 1 week...Full Text Available

1982-02-01

331

Monte Carlo modeling of 60Co HDR brachytherapy source in water and in different solid water phantom materials  

UK PubMed Central (United Kingdom)

The reference medium for brachytherapy dose measurements is water. Accuracy of dose measurements of brachytherapy sources is critically dependent on precise measurement of the source–detector...Full Text Available

2010-01-01

332

Modeling of soluble impurities distribution in the steam generator secondary water  

Energy Technology Data Exchange (ETDEWEB)

A model was developed to compute concentration of impurities in the WWER 440 steam generator (SG) secondary water along the tube bundle. Calculated values were verified by concentration values obtained from secondary water sample chemical analysis. (orig.). 2 refs.

1997-12-31

333

Measurement of the Water Potential of Stored Potato Tubers 1  

UK PubMed Central (United Kingdom)

A method of measuring the water potential of stored potato tubers (Solanum tuberosum L.) was needed to investigate the relationship of bacterial soft rot in tubers to water potential....Full Text Available

1985-11-01

334

Invasion and control of water hyacinth (Eichhornia crassipes) in China*  

UK PubMed Central (United Kingdom)

By the time of primary 21st century, water hyacinth had become a serious environmental problem in China. Water hyacinth contributes to the major part of ecological hazards from the invasion of foreign...Full Text Available

2006-08-01

335

In vivo Visualization of the Water-refilling Process in Xylem Vessels Using X-ray Micro-imaging  

UK PubMed Central (United Kingdom)

Background and AimsXylem vessels containing gases (embolized) must be refilled with water if they are to resume transport of water through the plant, so refilling is of great importance...Full Text Available

2008-03-01

336

Heat-transfer analysis of the plum brook reactor - NASA Technical ...  

Science.gov (United States)

average bulk water temper ature rise, OF bulk water temperature at elevation z, OF bulk water temperature in channels 0 and 1, O F film temperature, OF ...

337

Device for controlling water supply to nuclear reactor  

International Nuclear Information System (INIS)

Object: To smoothly control automatic water supply for realizing stable operation of a nuclear reactor by providing a flow rate limiting signal selection circuit and a preferential circuit in a water supply control device for a nuclear reactor wherein the speed of a recirculation pump may be changed in two-steps. Structure: Opening angle signals for a water supply regulating valve are controlled by a nuclear reactor water level signal, a vapor flow rate signal and a supplied water flow rate signal through an adder and an adjuster in response to a predetermined water level setting signal. When the water in the reactor is maintained at a predetermined level, a selection circuit receives a water pump condition signal for selecting one of the signals from a supplied water rate limiting signal generator ...

339

Bacterial indicators of risk of diarrhoeal disease from drinking-water in the Philippines.  

UK PubMed Central (United Kingdom)

Inadequate measures of water quality have been used in many studies of the health effects associated with water supplies in developing countries. The present 1-year epidemiological-microbiological study...Full Text Available

1991-01-01

340

Increasing concentrations of trihalomethanes (THMs) in a drinking water distribution network; Trihalometanos (THMs) en una red de distribucion de agua potable en alta  

Energy Technology Data Exchange (ETDEWEB)

THMs are disinfection by-products (DBPs) generated during water chlorination. Concentration of individual and total THMs, depends on treatment process and THMs precursors level. ATLL water utility has two DWTP (Llobregar and Ter) that produce and supply drinking water to Barcelona and regional area. This work studies the levels of THMs along the ATLL distribution system (450 km). Although, no differences were observed along water pipes system, changes of water resource and mix procedures were related. (Author) 12 refs.

1999-07-01

341

Fundamental R and D program on water chemistry of supercritical pressure water under radiation field  

International Nuclear Information System (INIS)

In a supercritical water-cooled reactor, property of water changes significantly around the critical point. It is expected that irradiation and change of water property will affect the chemistry and material corrosion. Deep understanding of interactions between supercritical water and materials under irradiation is important. However, comprehensive data on radiolysis, kinetics, corrosion and thermodynamics have not been obtained due to the severe experimental condition. To get such data by experiments and computer simulations, a national program funded by Ministry of Education, Culture, Sports, Science and Technology (MEXT) has been started since December 2002. (author)

2003-09-15

342

Evaluation of tritiated water retention capacity of fusion reactor concrete building  

Energy Technology Data Exchange (ETDEWEB)

In this paper the diffusion of tritiated water vapor into concrete walls is studied to evaluate tritiated water retention capacity of a fusion reactor concrete building. Using a model of the tritiated water diffusion determined form experimental results, depth profiles of tritiated water in concrete are calculated in the case of being exposed to air containing tritiated water vapor during the normal operational condition of a fusion reactor. A 0.5-m-thick concrete is sufficient for reactor hall walls from a viewpoint of the tritium containment.

1992-03-01

343

Evaluation of tritiated water retention capacity of fusion reactor concrete building  

International Nuclear Information System (INIS)

In this paper the diffusion of tritiated water vapor into concrete walls is studied to evaluate tritiated water retention capacity of a fusion reactor concrete building. Using a model of the tritiated water diffusion determined form experimental results, depth profiles of tritiated water in concrete are calculated in the case of being exposed to air containing tritiated water vapor during the normal operational condition of a fusion reactor. A 0.5-m-thick concrete is sufficient for reactor hall walls from a viewpoint of the tritium containment.

344

Water management studies in PEM fuel cells, part III: Dynamic breakthrough and intermittent drainage characteristics from GDLs with and without MPLs  

British Library Electronic Table of Contents (United Kingdom)

The transport of liquid water and gaseous reactants through a gas diffusion layer (GDL) is one of the most important water management issues in a proton exchange membrane fuel cell (PEMFC). In this work, the liquid water breakthrough dynamics, characterized by the capillary pressure and water saturation, across GDLs with and without a microporous layer (MPL) are studied in an ex-situ setup which closely simulates a real fuel cell configuration and operating conditions. The results reveal that recurrent breakthroughs are observed for all of the GDL samples tested, indicating the presence of an intermittent water drainage mechanism in the GDL. This is accounted for by the breakdown and redevelopment of the continuous water paths during water drainage as demonstrated by Haines jumps. For GDL ...

2010-01-01

345

Water You Engineering? An Activity to Develop Water-Quality Awareness  

Science.gov (United States)

Water is one of our most precious resources. However, for many in the United States, having fresh, safe drinking water is taken for granted, and due to this perceived lack of relevance, students may not fully appreciate the luxury of having safe running water--in the home. One approach to resolving water-quality issues in the United States may reside in providing education that presents accurate information in a meaningful way. Accordingly, this article describes a unit designed to emphasize the importance of water-quality testing and purification and to introduce students to local water-quality issues. The engineering-based module of this eighth-grade science activity is particularly important due to the design-build-test component. (Contains 5 figures.)

2009-04-01

346

Thermal- and radiation-induced interactions of water on U02 surfaces.  

Energy Technology Data Exchange (ETDEWEB)

Most plans for the disposition of surplus nuclear materials involve storage in sealed containers where the evolution of gases from reactions of adsorbed water could present both pressure and flammability hazards[l] . Despite efforts such as calcining the material to minimize the water content prior to packaging, both residual moisture and readsorbed water may be present in the final containers . Given the anticipated temperature excursions during transportation and storage, this water may thermally desorb, increasing the pressure, and/or thermally dissociate to produce H2 gas, increasing flammability hazards . In addition, the radiation from the nuclear material may induce radiolysis of the water with the likely products being water vapor, H2, 02 and H2O2. In order to better understand the relative importance of the thermal- and radiationinduced chemistry, we ...

2003-01-01

347

Simulation of ground-water flow in the basin-fill aquifer of the Tularosa Basin, south-central New Mexico, ...  

Science.gov (United States)

... percent by interbasin ground-water flow into the Hueco Bolson, and 2 percent by flow into creeks and ... ...

348

Radon concentration measurements at water reservoirs  

International Nuclear Information System (INIS)

Ground water is treated in the Czech Republic so that small water tanks are built above each water source to serve the primary ground water treatment; water so pretreated is then concentrated in large basins for subsequent treatment. Some water tanks where the first contact of the ground water with air takes place were selected as sites predisposed to radon accumulation. The examination was carried out near the town of Jihlava, where the bedrock contains slightly elevated radium concentrations. The average radon concentrations lay within the region of 2-4 kBq/m"3; the instantaneous values, however, exhibited appreciable periodical variations during the day. The relatively high radon concentrations will not pose a marked hazard for the personnel because the employees only reside at the sites in question for 10 to 15 minutes within 2 days, not ...

1998-09-09

350

Pipe Freeze Prevention for Passive Solar Water Heaters Using a Room-Air Natural Convection Loop: Preprint  

Energy Technology Data Exchange (ETDEWEB)

Conference paper regarding research in the use of freeze prevention for passive solar domestic water heating systems.

2006-05-01

351

Performance of single cylinder, direct injection diesel engine using water fuel emulsions  

Energy Technology Data Exchange (ETDEWEB)

A single cylinder diesel engine study of water-in-diesel emulsions was conducted to investigate the effect of water emulsification on the engine performance and gases exhaust temperature. Emulsified Diesel fuels of 0, 5, 10, 15 and 20 water/diesel ratios by volume were used in a single cylinder, direct injection diesel engine, operating at 1200-3300 rpm. The results indicate that the addition of water in the form of emulsion improves combustion efficiency. The engine torque, power and brake thermal efficiency increase as the water percentage in the emulsion increases. The average increase in the brake thermal efficiency for 20% water emulsion is approximately 3.5% over the use of diesel for the engine speed range studied. The proper brake specific fuel consumption and gases exhaust temperature decrease as the percentage of water in the ...

2004-03-01

352

Oreochromis lepidurus  

Science.gov (United States)

... Marine transport and oil disposal by boats and Matadi pose threats in the region. When the water ... Marine transport and oil disposal by boats and Matadi pose threats in the region. When the water ... ...

353

Oceanographic Processes and Marine Productivity in Waters Offshore ...  

Science.gov (United States)

Jun 16, 2011 ... Title: Chapter 21: Oceanographic Processes and Marine Productivity in Waters Offshore of Marbled Murrelet Breeding Habitat ...

354

Ocean Water: Density  

Science.gov (United States)

This site explains how temperature, pressure, and salinity work together to determine the density of ocean water. The three density layers of the ocean are described by means of text description and a graphic illustration.

355

NASA 11x:/,3 '/t.z- - NASA Technical Reports Server  

Science.gov (United States)

_! Packaging, Cleanlines_, Preparation j Handling ..... 35. 'I. 40. WATER ................ , ......... Sterile, High Purity, Ethylene Glycol-Water Solutions. Requirement For . ...

356

N. Mariana Islands Wildlife Action Plan  

Science.gov (United States)

... will utilize man-made habitats, including artificial wetlands, waste water ponds, water hazards on golf courses, and an abandoned ... ...

357

Managing a large outbreak of cryptosporidiosis: how to investigate and when to decide to lift a 'boil water' notice.  

Science.gov (United States)

The largest outbreak of cryptosporidiosis reported in the United Kingdom, involving 575 confirmed cases (of which 474 met an agreed case definition), occurred in the county of Devon during August and September of 1995. The descriptive epidemiology supports the hypothesis that the outbreak was associated with the consumption of cold tap water in the area served by a particular water treatment works. Cryptosporidium oocysts were detected in treated water samples at the time of the outbreak. Although the epidemiological analysis provided strong circumstantial evidence of a waterborne outbreak, the data were not recorded in a manner that made them admissible in criminal proceedings taken by the Drinking Water Inspectorate against the water company involved. The need to carry out an analytical study in conjunction with the identification and characterisation of the pathogen in the ...

2002-09-01

358

MTF ' MISSISSIPPI SOUND REMOTE SENSING STUDY I 19 SEPTEMBER 1972  

Science.gov (United States)

metric temperatures has been prepared showing the surface water temper- ... occasion, gray levels show different densities for similar water temper- ...

359

JPRS Report, Science & Technology, China: Energy  

Science.gov (United States)

... should give full con- As for the effects of the Three Gorges on the mouth of sideration to the rising water process and water temper- the river, the ...

1991-08-23

361

Ground-Water Data for the Suck Creek Area of Walden Ridge ...  

Science.gov (United States)

... Where Suck Creek enters the river, a formidable whirlpool and 2 Ground-water data for the Suck Creek area of Walden Ridge, Southern ...

2011-05-14

362

Fetal cardiotocography before and after water aerobics during pregnancy  

UK PubMed Central (United Kingdom)

ObjectiveTo evaluate the effect of moderate aerobic physical activity in water on fetal cardiotocography patterns in sedentary pregnant women.MethodIn...Full Text Available

363

Equipment for a central heating system with expansion tank, pressure control, water loss supply, de-aeration, recording and control; Apparaat t.b.v. C.V.-installatie met expansievat, drukregeling, waterverliessuppletie, ontluchting, registratie en controle  

Energy Technology Data Exchange (ETDEWEB)

The very low-pressure expansion tank of the title invention is connected to the water in the central heating installation via a connecting pipe with a pump and valves on one side, and on the other side the tank is connected via a connecting pipe with valve to the tap water mains, so that the supply of water can be regulated automatically. Within the expansion tank contact with the outside air is not possible because of an air/water separating floater. By means of recording and control (also remote) of the contents of the expansion tank, the installation pressure and the quantity of supplied water from the expansion tank and the tap water mains, failures and water damage are prevented. 4 figs.

1995-09-01

364

Ecology of Vibrio mimicus in aquatic environments.  

UK PubMed Central (United Kingdom)

An environmental study was done to examine the prevalence of Vibrio mimicus in some aquatic environments of Dhaka, Bangladesh, and of Okayama, Japan. Water samples from Dhaka environments and water...Full Text Available

1989-08-01

365

Density: Sea Water Mixing and Sinking - Aquarius - NASA  

Science.gov (United States)

density is slightly higher, its electrical conductivity is much higher, and it is slightly ... Sea water has characteristic properties (e.g. density) that are independent of ...

366

Assessing vineyard water status using the reflectance based Water Index  

British Library Electronic Table of Contents (United Kingdom)

In the Mediterranean arc, vines for wine production are mainly grown without the support of irrigation. Under such conditions, site variables affecting the extent and seasonal timing of water deficits are the dominant environmental constraints for grape production. Moreover, water availability and vine water status are the factors most comprehensively determining fruit composition and, thus, wine quality. Therefore, monitoring the extent of water stress in vines might be a valuable tool for the optimisation of grape yield and quality. The objective of this study was to evaluate the feasibility of using the reflectance based Water Index (WI) to estimate vine water status at the leaf and canopy levels. The study was conducted on Vitis vinifera cv. Chardonnay potted plants submitted to contra...

2010-01-01

367

Aqueous water-soluble soap lubricant concentrates and aqueous lubricants containing same  

Energy Technology Data Exchange (ETDEWEB)

The inclusion of neodecanoic acid in aqueous water-soluble soap lubricants reduces viscosity, and improves lubricity effectiveness.

1981-06-23

368

Anesthetic stimulation of insect water receptors.  

UK PubMed Central (United Kingdom)

Halothane, chloroform, and carbon tetrachloride, in the vapor and liquid phases, stimulate the water receptor of the blowfly Phormia regina. There are three successive phases of response to long-lasting...Full Text Available

1976-09-01

369

The numerical simulation on low-level radioactive waste water, low-temperature cooling water drained effect of implement from the Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

In this paper, we calculated the radioactive concentration distribution of radioactive waste water, the temperature distribution of drained cooling water and the effect of implement from the Daya Bay Nuclear Power Plant on nearby waters range, discussed and analysed some problems of computational results and computation with Alternating Direction Implicit Method (ADI). The contents of the article included: the establishment of two-dimension tidal current equation, radioactive waste water pollutant dispersion equation and cooling water heat convection diffusion equation, the numerical difference calculation model of tidal current field, concentration field as well as temperature field, effect impingement with ADI method, numerical calculation results. The result of research showed that: when the Daya Bay Nuclear Power Plant is on normal operation and after the low level radioactive ...

370

High quality water supply system; Joshitsusui kyokyu system  

Energy Technology Data Exchange (ETDEWEB)

This paper, firstly, introduces the background in developing a high quality water supply system, in which the drinking water system is isolated inside a building. Results of questionnaire on the high quality service water are illustrated. The results of questionnaire have revealed that the high quality service water is extremely interested. Then, are described the target quality of high quality water, the constitution of high quality water supply system, the treatment process, the measures to secure safety and sanitary, and the method of maintenance. The high quality water is produced through the activated charcoal absorption treatment, membrane treatment, ozonation, cooling, mineral addition, and disinfection of city water. Furthermore, application examples of this system adopted to a department store and a bachelor ...

1995-01-15

371

Environmental levels of tritium, 2  

International Nuclear Information System (INIS)

In an attempt to obtain basic data for evaluation of exposure doses in Niigata Prefecture, the concentrations of tritium in atmospheric water, precipitation, river water, and tap water were measured. Samples of atmospheric water, river water, and tap water were collected once for 2 weeks; and precipitation collected for one week was used as sample. The concentration of atmospheric tritium depended on the concentration of tritium in moisture and the content of water in atmosphere. Tritium levels were high in May, November and March, and low in September. Regarding tritium concentrations, there was a good correlation between atmospheric water and precipitation. Tritium concentrations in both of them varied from sample to sample. The concentrations of tritium in river and tap water tended to be high ...

373

Water conservation in agriculture -a step in combating the water crisis  

International Nuclear Information System (INIS)

In Pakistan, the agricultural sector is the largest water user with 95%, leaving only marginal quantities for households and industry. On one hand, agriculture is a very important sector in Pakistan's economic development, contributing about 23 % to the national GDP -but industry contributes slightly more using only about 2 % of the available water resources. As Pakistan faces a growing problem of water shortage, significant achievements in water conservation have to be materialized, predominantly on the agricultural sector. There is scope for a higher degree of efficiency in water use, as water losses, namely in irrigation, are still rather high. There is another good reason for water conservation in agriculture: Over-irrigation results in rising water tables and increased soil salinity, which has reduced Pakistan's ...

2004-06-07

377

THE EFFECTS OF ONE MEGACYCLE ULTRASONIC ...  

Science.gov (United States)

... ULTRASONIC VIBRATION TO PORTLAND CEMENT-WATER PASTE REDUCES THE ULTIMATE COMPRESSIVE STRENGTH OF MORTARS ...

1959-09-09

378

Survey of state water quality standards for wetlands  

Energy Technology Data Exchange (ETDEWEB)

This document summarizes the degree to which State water quality standards include wetlands in their definitions of State waters. The detailed review of other elements of standards, such as uses, criteria and antidegradation, is beyond the scope of this review. The purpose of this review is to provide a baseline of information for the development of EPA guidance and policies related to water quality standards for wetlands.

1989-08-17

381

Sinus Surgery  

Medline Plus

... know if the drainage becomes very clear, like tap water. This may be the first indication that there ...

384

Pillared Clays as Catalysts and Sorbents  

International Science & Technology Center (ISTC)

New Catalysts and Sorbents on the Basis of Pillared Clays for the Processes of Hydrocarbons Conversion and Water Purification

386

Nuclear Thermal Propulsion engine based on Particle Bed Reactor using light water steam as a propellant  

Energy Technology Data Exchange (ETDEWEB)

In this paper the possibility of configuring a water cooled Nuclear Thermal Propulsion (NTP) rocket, based on a Particle Bed Reactor (PBR) is investigated. This rocket will be used to operate on water obtained from near earth objects. The conclusions reached in this paper indicate that it is possible to configure a PBR based NTP rocket to operate on water and meet the mission requirements envisioned for it. No insurmountable technology issues have been identified.

1993-06-01

387

Mormyrops mariae  

Science.gov (United States)

... Marine transport and oil disposal by boats and Matadi pose threats in the region. When the water ... ...

388

Mormyrops curtus  

Science.gov (United States)

... Marine transport and oil disposal by boats and Matadi pose threats in the region. When the water ... ...

389

Member Login | Join / Register with EUGRIS  

Wastenet

...In 2000, the Water Framework Directive (WFD) came into force, introducing a comprehensive, river basin based water management for Europe. The aim of the Directive is ...In 2000, the Water Framework Directive (WFD) came into force, introducing a comprehensive, river basin based water management for Europe. The aim of the Directive ...

392

High resolution neutron imaging of water in the polymer electrolyte fuel cell membrane  

Energy Technology Data Exchange (ETDEWEB)

Water transport in the ionomeric membrane, typically Nafion{reg_sign}, has profound influence on the performance of the polymer electrolyte fuel cell, in terms of internal resistance and overall water balance. In this work, high resolution neutron imaging of the Nafion{reg_sign} membrane is presented in order to measure water content and through-plane gradients in situ under disparate temperature and humidification conditions.

2009-01-01

393

General corrosion of ALLOY 800 in high temperature water and its prevention  

Energy Technology Data Exchange (ETDEWEB)

General corrosion behavior of ALLOY 800 in high temperature water was studied in relation to its surface film structure. The surface film formed in water was found to decrease the corrosion rate of ALLOY 800. This film is composed of Ni ferrite, and can be obtained by oxidation in air or steam. Based on these results, air or steam oxidation treatment to inhibit Ni and Co release of ALLOY 800 into high temperature water is proposed. (author).

1989-10-01

394

General corrosion of ALLOY 800 in high temperature water and its prevention  

International Nuclear Information System (INIS)

General corrosion behavior of ALLOY 800 in high temperature water was studied in relation to its surface film structure. The surface film formed in water was found to decrease the corrosion rate of ALLOY 800. This film is composed of Ni ferrite, and can be obtained by oxidation in air or steam. Based on these results, air or steam oxidation treatment to inhibit Ni and Co release of ALLOY 800 into high temperature water is proposed. (author).

396
398

Evaluation of a computer program used to estimate water characteristic curve  

Science.gov (United States)

The soil water characteristic curve, h(theta), can be used to estimate a variety of parameters in unsaturated soils. One practical application of h(theta) is its use by DRAINMOD, a drainage model that has been widely used in shallow water table regions, to determine the water table depth¿drainage v...

408

Conference on climate and water. Volume 2  

Energy Technology Data Exchange (ETDEWEB)

This book contains the Proceedings of the Conference on Climate and Water under the following groupings: Impacts of climatic variability and change-resulting from the changes in hydrological variables; Aquatic environment; Terrestrial environment; Coastal zones and navigation; Urban and industrial water supply and drainage; Energy production; Intropogenic changes of climate and water management problems; Flood potential; Irrigation and land drainage.

1989-12-31

409

Conference on climate and water  

Energy Technology Data Exchange (ETDEWEB)

This book contains the Proceedings of the Conference on Climate and Water under the following groupings: Impacts of climatic variability and change-resulting from the changes in hydrological variables; Aquatic environment; Terrestrial environment; Coastal zones and navigation; Urban and industrial water supply and drainage; Energy production; Intropogenic changes of climate and water management problems; Flood potential; Irrigation and land drainage.

1989-01-01

410

China's water crisis  

Energy Technology Data Exchange (ETDEWEB)

After the devastating natural disasters that have hit China recently, another crisis is looming, Drought, pollution and heavy usage in the fast-developing megacities have resulted in a shortage of water. A huge construction effort is underway to divert water from the south to the north. But experts warn that it will not solve China's structural water problems.

2008-07-15

411

Aquatic Therapy  

Science.gov (United States)

... use of water in wound management, such as whirlpool baths, but can be used interchangeably with the ...

422

Aerosols Equipment in Manitoba on Environmental Expert  

Wastenet

... Hale, Markku Kulmala, 373.43 EUR; 225.00 USD; 276.00 GBP... Aerosol Chemical Processes in the Environment Spurny, Kvetoslav R., $164,95, 䀈... More Journals » MAGAZINES & JOURNALS Water Science & Technology: Water Supply Water Science and Technology: Water Supply is p... ...

426

46 CFR 63.25-3 - Electric hot water supply boilers.  

Science.gov (United States)

...2010-10-01 false Electric hot water supply boilers. 63.25-3 Section 63.25-3...Boilers § 63.25-3 Electric hot water supply boilers. (a) Electric hot water supply boilers that have a capacity not...

2010-10-01

427

W1045 environment surf drip shield and waste package outer barrier  

Energy Technology Data Exchange (ETDEWEB)

The environments on the drip shield and waste package outer barrier are controlled by the compositions of the waters that contact these components. the temperature (T) of these components, and the effective relative humidity (RH) at these components. Because the composition of the waters that are expected to enter the emplacement drifts (either by seepage flow or by episodic flow) have not been specified: well J13 water was chosen as the reference water (Harrar 1990). Section 6.2 discusses the accessible RH for the temperatures of interest at the repository horizon. Section 6.3 discusses the adsorption of water on metal alloys in the absence of hygroscopic salts. Because the temperatures of the DSs and the WPOBs are higher than those of the surrounding near-field environment, the relative humidity at the DSs and the WPOBs will be lower than that of the surrounding near-field ...

1999-07-14

428

Thermal gradient humidification-dehumidification desalination system  

Energy Technology Data Exchange (ETDEWEB)

A solar energy desalination process utilizing solar radiation directly for the evaporation of salt water is described. Ambient air takes on water vapor as the air passes through an evaporative medium. It is then directed between a saline water-covered, solar absorbing surface and a solar collecting housing. The resulting heated and moisture-saturated air is cooled in a heat exchange means where condensation of fresh water occurs. Simultaneously, cool salt water is utilized as the cooling water in the heat exchange means, and takes on the heat of condensation given up by the condensing vapor. The heated salt water from the heat exchange means is partially directed over the solar absorbing surface, and at least a portion of it is also directed to wet the evaporative medium. Several optional sub-processes are described for operation of the ...

1982-12-14

429

The external water footprint of the Netherlands: Geographically-explicit quantification and impact assessment  

British Library Electronic Table of Contents (United Kingdom)

This study quantifies the external water footprint of the Netherlands by partner country and import product and assesses the impact of this footprint by contrasting the geographically-explicit water footprint with water scarcity in the different parts of the world. The total water footprint of the Netherlands is estimated to be about 2300 m^3/year/cap, of which 67% relates to the consumption of agricultural goods, 31% to the consumption of industrial goods, and 2% to domestic water use. The Dutch water footprint related to the consumption of agricultural goods, is composed as follows: 46% related to livestock products; 17% oil crops and oil from oil crops; 12% coffee, tea, cocoa and tobacco; 8% cereals and beer; 6% cotton products; 5% fruits; and 6% other agricultural products. About 11% o...

2009-01-01

430

Temporal variations of fluoride concentration in Isparta public water system and health impact assessment (SW-Turkey)  

British Library Electronic Table of Contents (United Kingdom)

Water?rock interaction is one of the prime factors affecting the fluoride contents of surface and groundwater. If fluoride concentration of drinking water has been neglected, excess fluoride can cause serious dental and medical problems on human health, which is well known at Golcuk-Isparta region. In the research area, Egirdir lake, Golcuk lake and surrounding springs have been utilized as drinking water sources. Golcuk lake water and surrounding groundwaters have high fluoride content (1.4?4.6?mg/l), which is above the WHO standards. Fluoride is predominantly supplied by dissolution of fluoride within the fluormicas of volcanics during the circulation of water. Fluoride concentrations of waters have shown variations for dry and rainy seasons depending on the degree of interaction between...

2008-01-01

431

Predicting urban forest growth and its impact on residential landscape water demand in a semiarid urban environment  

British Library Electronic Table of Contents (United Kingdom)

We present an innovative approach to estimating residential irrigation water demand for a large metropolitan area using GIS data, weather station data, and a water budget modeling approach commonly used by plant scientists and landscape management professionals. An important question addressed by our study is how a growing urban forest affects the overall irrigation water demand of a semiarid metropolitan area. To estimate the amount of water required by residential landscaping, we consider water demand to be a function of the areal extent of residential landscaping (i.e. tree/shrub or turf grass), the water-loss rate for different landscaping types, the efficiency with which the landscape is irrigated, and local climatic factors (i.e. reference evapotranspiration and precipitation). We es...

2011-01-01

432

Feedwater control device for a reactor  

International Nuclear Information System (INIS)

Purpose: To stably control the reactor water level so as not to cause excess water feeding in a BWR type reactor. Constitution: A flow control valve is disposed to the exit of a feedwater pump for a nuclear reactor and the valve is controlled by a flow regulator to maintain the water level constant in the reactor. A signal from a water level controller is inputted to the flow regulator to thereby control the flow rate control valve. In this case, the flow regulator remains in a saturated state just after the starting of the feedwater pump, in which the pump flowrate is at 100% to result in an excess water feeding condition. In view of the above, a feedback circuit is provided to the flow regulator so that the saturated state is eliminated and the water feeding can be controlled directly from the water level controller. (Kamimura, M.).

1981-11-12

433

Control rod devices  

International Nuclear Information System (INIS)

Purpose: To remove excessive driving pressure applied to an unisolated control rod drive by returning excessive coolant to a condensed water storage tank or to the inlet side of a drive water pump using a coolant flow rate control pipe of a control rod driving hydraulic system. Constitution: Excessive water is returned to a condensed water tank while controlling the excessive coolant by a flow control valve in response to variations in the pressure difference between the reactor pressure and the driving water line when the control rods are isolated using a pipe from the outlet side of the drive water pump to the condensed water storage tank. Thus, the control rod to be isolated is prevented form being dropped. (Sekiya, K.).

434

Assessing variability of water quality in a groundwater-fed perennial lake of Kashmir Himalayas using linear geostatistics  

British Library Electronic Table of Contents (United Kingdom)

This paper presents a study on Manasbal lake, which is one of the high altitude lakes in the Kashmir Valley, India. Eighteen water samples were analysed for major ions and trace elements to assess the variability of water quality of the lake for various purposes. Geostatistics, the theory of regionalized variables, was then used to enhance the dataset and estimate some missing spatial values. Results indicated that the concentration of major ions in the water samples in winter was higher than in summer. The scatter diagrams suggested the dominance of alkaline earths over the alkali elements. Three types of water were identified in the lake that are referred to as Ca?HCO3, Mg?HCO3 and hybrid types. The lake water was found to be controlled by rock?water interaction with carbonate lithology ...

2011-01-01

435

Assessing Ground Water Development Potential Using Landsat Imagery  

British Library Electronic Table of Contents (United Kingdom)

Seven villages in southeastern Kenya surround Mt. Kasigau and depend on the mountain's cloud forest for their water supply. Five of these villages have regularly experienced water shortages, and all village water supplies were contaminated with Escherichia coli bacteria. There is a need to economically find new sources of fresh ground water. Remote sensing offers a relatively quick and cost-effective way of identifying areas with high potential for ground water development. This study used spectral properties of features on Landsat remote sensing imagery to map linear features, soil types, surface moisture, and vegetation. Linear features represented geologic or geomorphologic features indicating either shallow ground water or areas of increased subsurface hydraulic conductivity. Regarding...

2010-01-01

436

Ultratrace analysis of mercury and methylmercury (MM) in rain water using cold vapor atomic absorption spectrometry  

Energy Technology Data Exchange (ETDEWEB)

Ultratrace analysis of mercury in rain water has been investigated, including recovery of ionic mercury with the addition of acids, treatment and storage and stability studies of mercury in rain water. Recovery of ionic mercury from rain water samples increased with increased acid concentrations and increased substantially with UV-irradiation. Recovery of ionic mercury in the presence of different acids was compared. Treatment studies of rain water for the analysis of total mercury were done using different decomposition methods. More than 20% of the total mercury was found in rain water residue after filtration through 0.45 ..mu..m membrane filters. Methylmercury (MM) content in filtered and unfiltered rain water however was nearly the same. On long term storage of rain water without acids at pH = 2.0 and 4.5 loss of total mercury occurred, ...

1987-03-01

437

Tritium in surface waters, tap water and in precipitation in Poland during the 1994-1999 period  

International Nuclear Information System (INIS)

Concentrations of tritium in environmental waters (precipitation, rivers, lakes, tap water) have been determined using electrolytic enrichment and liquid scintillation counting. In waters of big rivers (the Vistula and the Odra rivers), lakes and tap water the annual average concentrations were similar to each other being from 1.4 to 1.9 Bq x dm"-"3. These concentrations were similar to those in the precipitation in which they ranged from 1.7 to 2.2 Bq x dm"-"3. The lowest tritium concentrations were found in waters of the Seashore Region rivers (average for 1994-1999 was 1.1 Bq x dm"-"3). The tritium concentrations in surface waters and in precipitation are still higher than that of natural level. The data obtained show that tritium concentration in the water of rivers might depend on the size of drainage area. The observed seasonal ...

2001-01-01

438

The use of isotopes in hydrology: Proceedings of a symposium, held in Beirut -Lebanon, December 1970  

International Nuclear Information System (INIS)

The papers presented at the symposium had covered three general areas in which isotopes could have been beneficially used. these areas are: -Water use and water use efficiency studies. -Ground water investigations -Water problems in the arab countries. The individual papers had dealt with these subjects: -Hydrological research in the arab countries by use of radioisotopes. -The perspectives of use of radioisotopes in hydrological studies in Syria. -Water use efficiency and sub-soil water studies. -Sea water inclusion in a coast el aquifers in Lebanon. -Irrigation requirements of crops in Lebanon as determined by a Neutron probe with reference to other methods. -The use of the neutron moisture meter and other methods of the determination of the evapotranspiration of maize. -Ground water investigations, dating and nuclear ...

1970-12-01

439

Soil water retention at varying matric potentials following repeated wetting with modestly saline-sodic water and subsequent air drying  

Energy Technology Data Exchange (ETDEWEB)

Coal bed natural gas (CBNG) development in the Powder River (PR) Basin produces modestly saline, highly sodic wastewater. This study assessed impacts of wetting four textural groups (0-11%, 12-22%, 23 -33%, and > 33% clay (g clay/100 g soil) x 100%))with simulated PR or CBNG water on water retention. Soils received the following treatments with each water quality: a single wetting event, five wetting and drying events, or five wetting and drying events followed by leaching with salt-free water. Treated samples were then resaturated with the final treatment water and equilibrated to -10, -33, -100, -500, or -1,500 kPa. At all potentials, soil water retention increased significantly with increasing clay content. Drought-prone soils lost water-holding capacity between saturation and field capacity with repeated wetting and drying, ...

2007-07-01

440

Glass Transition Behaviors of Ethylene Glycol-Water Solutions Confined within Nano-Pores of Silica Gel  

Science.gov (United States)

Enthalpy relaxation properties of the ethylene glycol (EG) aqueous solutions confined within silica-gel void spaces of 1.1 nm in the average void thickness and 6, 12 and 52 nm in their average diameters were examined by an adiabatic calorimetry to understand the glass transition behavior of the solutions and the rearrangement processes of the molecules. The glass transition temperature Tg of EG was found to decrease with adding the water molecules which are mobile under the condition lacking in the full hydrogen-bond network. Meanwhile, the Tg in the water-rich region showed a rise towards pure water; after a phase separation in a 25 mol% (x = 0.25) EG solution, the Tg was 160 K which was higher than that derived by extrapolating the composition dependence to pure water. The Tg = 160 K is the same as observed in the pure water confined within 1.1 nm voids; this indicates the ...

2008-02-01

441

The use of treated wastewater for chemlali olive tree irrigation: effects on soil properties, growth and oil quality  

Energy Technology Data Exchange (ETDEWEB)

Olive tree (Olea european L.) cultivation, the major tree crops in Mediterranean countries is being extended to irrigated lands. However, the limited water availability, the severe climatic conditions and the increased need for good water quality for urban and industrial sector uses are leading to the urgent use of less water qualities (brackish water and recycled wastewater) for olive tree irrigation. The aim of this work was to asses the effects of long term irrigation with treated waste water (TWW) on the soil chemical properties, on olive tree growth and on oil quality characteristics. (Author)

2009-07-01

442

Method for limiting scram discharge water  

International Nuclear Information System (INIS)

Object: To limit the discharge amount of reactor water in a primary system at the time of scram to prevent excessive outflow of reactor water outside the system. Structure: A signal from an upper limit position indicator detects the fact that control rods are completely inserted when the reactor is urgently stopped and the detection signal causes a valve in an outflow line of the discharge water from a control rod driving mechanism to be closed to limit the amount of discharge flown into the scram discharge vessel, thus preventing outflow of reactor water in the primary system after the scram has been initiated. (Kamimura, M.).

443

Experimental study on the texture of falling water of free falling and slope falling types; Jiyu rakkagata to etsuryugata no rakusui hyojo ni tsuite no jikkenteki kenkyu  

Energy Technology Data Exchange (ETDEWEB)

A full scale experiment was carried out to investigate the texture characteristics of the falling water of free falling and slope failing types. According to the increase of Reynolds number, the texture of falling water was classified into three categories for both types: stability of free surface, transition and whole turbulence. In the first category the stability of the free surface was related to the growth of minute disturbance. Surface tension works as a counter, force to the disturbance in free falling water, and gravity in slope falling water. 14 refs., 15 figs., 3 tabs.

1998-05-21

444

Development of a geothermal heat pump. Final report  

Energy Technology Data Exchange (ETDEWEB)

In the development of a geothermal heat pump a water source heat pump was connected to a 1-1/2'' water line, 2200' long, buried in an endless loop 10' deep. The system is closed, circulating the same water continuously through the heat pump back to the field again. This water line 10' deep is the geothermal heat source. No matter how cold the air temperature gets on a winter day the water temperature to the heat pump will always be above 45/sup 0/F. This system has efficiently heated our house the past year using no supplemental heat.

1981-11-02

445

Thermal and radiation losses in a linear device  

Energy Technology Data Exchange (ETDEWEB)

An analysis is presented of the electron temperature in a linear device which includes the effect of thermal conduction, heat flux limit, radiation, and end plugs. It is found that the thermal conduction and the heat flux limit are dominant in the initial phase of cooling, while the later phase is almost completely controlled by radiation that spatially homogenizes the temperature distribution. In the case of bremsstrahlung, within the frame of the present model, the temperature decays to zero in a finite time. This process takes the form of a cooling wave that moves from the ends of the column to the center. Impurities cause a milder, exponential decay, which is still much faster than the algebraic conduction decay. The thermal effectiveness of the end plugs is described by a convective transfer coefficient h/sub p/. Its scaling law (in terms of the coupled plamsa-plug system) reveals that a very high plug-plasma density ratio provides a simple way to ...

1980-11-01

446

The structure of molecular clouds - III. A link between cloud structure and star formation mode  

British Library Electronic Table of Contents (United Kingdom)

Abstract We analyse extinction maps of nearby giant molecular clouds to forge a link between driving processes of turbulence and modes of star formation. Our investigation focuses on cloud structure in the column density range above the self-shielding threshold of 1-mag AV and below the star formation threshold - the regime in which turbulence is expected to dominate. We identify clouds with shallow mass distributions as cluster forming. Clouds that form stars in a less clustered or isolated mode show a steeper mass distribution. Structure functions prove inadequate to distinguish between clouds of different star formation mode. They may, however, suggest that the turbulence in the average cloud is governed by solenoidal forcing. The same is found using the -variance analysis which also in...

2011-01-01

447

Ternary diagram plotting software design using the tie-line slope method  

Energy Technology Data Exchange (ETDEWEB)

Ternary diagrams are commonly used to provide a graphic representation of equilibrium fluid phase behavior for systems as diverse as distillation columns and miscible gas floods of oil reservoirs. The phase envelope, and the position of the critical point on it, are important to enhanced oil recovery engineers who are involved with miscible gas flood design. In the past, phase equilibrium data were laboriously plotted on the ternary diagram and special graphic techniques were utilized to locate the critical point on the phase envelope. This work presents a computerized curve fitting method to generate the phase envelope from a given set of phase equilibrium data and then use the tie-line slopes to position the critical point. Experimental data are included and show excellent agreement with this new method.

1982-01-01

448

Ternary diagram plotting software design using the ''tie-line slope'' method  

Energy Technology Data Exchange (ETDEWEB)

Ternary diagrams or pseudo ternary diagrams are commonly used to provide a graphical representation of equilibrium fluid phase behavior for systems as diverse as distillation columns and miscible gas floods of oil reservoirs. The phase envelope and the position of the critical point on it are important to enhanced oil recovery engineers who are involved with miscible gas flood design. In the past, phase equilibrium data were laboriously plotted on the pseudo ternary diagram and special graphical techniques were utilized to locate the critical point on the phase envelope. Presented in this article is a computerized curve fitting method to, firstly, generate the phase envelope from a given set of phase equilibrium data and then use the 'tie-line slopes' to position the critical point. Experimental data are included and show excellent agreement with this new method.

1983-01-01

449

THERMAL-NEUTRON FISSION CROSS SECTIONS FOR ISOTOPES OF PLUTONIUM, AMERICIUM, AND CURIUM  

Science.gov (United States)

The following thermal-neutron fission cross sections have been measured in the thermal column of the Materials "Testing Reactor at Idaho Falls, Idaho: Pu/ sup 238/, 18.4 plus or minus 0.9 b; Am/sup 241/, 3.13 plus or minus 0.15 b; Am/sup 245/, 6390 plus or minus 500 b; Am/sup 243/, <0.072 b Cm/sup 243/, 690 plus or minus 50 b; Cm/sup 245/, 1880 plus or minus 150 b. In addition, a pile neutron capture cross section of 520 plus or minus 40 b has been measured for Pu/sup 238/. (auth)

1957-09-01

450

Synthesis of C-11 iodoantipyrine for positron emission tomography  

Energy Technology Data Exchange (ETDEWEB)

We have developed a method for the synthesis of C-11 iodoantipyrine. Carbon-11-labeled methyl iodide, prepared from /sup 11/CO2, was used to methylate 3-methyl-1-phenyl-2-pyrazolin-5-one to form C-11 antipyrine. Following silica-gel column chromatography and iodination, radiochemical purity of the C-11 iodoantipyrine was more than 99.5%, with a 10% yield and a specific activity of 30 mCi/mumol. Preliminary animal studies showed complete cerebral extraction and local cerebral blood-flow values that were within 4.6% of those obtained using C-14 iodoantipyrine. The C-11 analog, with positron emission tomography, will facilitate local cerebral blood-flow studies in human subjects.

1981-06-01

451

Spinal axis irradiation with electrons: Measurements of attenuation by the spinal processes  

Energy Technology Data Exchange (ETDEWEB)

Electrons may be used beneficially for spinal axis irradiation in medulloblastoma children to avoid some of the long-term sequelae induced by megavoltage photons. However, the attenuation by the intervening bone ought to be considered. Three-dimensional computer treatment planning with inhomogeneity correction for electron beams is not yet generally available, and alternate methods are needed to evaluate the attenuation by the complex bony structure of the spine. Here, we present our experimental data showing the alteration in the electron isodoses due to the intervening spinous processes. Film dosimetric measurements were made in the vertebral columns obtained from autopsies of a goat, a dog, and a child. Our results show that electron beam therapy for the spinal axis is a viable option.

1986-07-01

452

Serum TNF-Related and Weak Inducer of Apoptosis Levels in Septic Shock Patients  

British Library Electronic Table of Contents (United Kingdom)

Abstract Capillary permeability is a tightly regulated feature of microcirculation in all organ beds. In sepsis, this feature is fundamentally altered. We have previously reported elevated levels of angiopoietin-2 in patients with septic shock, and have investigated tumor necrosis factor (TNF)-related and weak inducer of apoptosis (TWEAK), which mediates both angiogenesis and inflammation, in those patients. Enzyme-linked immunoassay was used to measure serum TWEAK levels in 20 patients with septic shock, all of whom were treated by direct hemoperfusion with a polymyxin B-immobilized fiber column (DHP-PMX), and in 20 non-septic controls. The TWEAK levels were higher in patients with septic shock (192.8--230.5-pg/mL) than in controls (84.1--28.7-pg/mL, P-=-0.043). Between 11 survivors and 1...

2011-01-01

453

Security features of a nuclear material accounting system  

Energy Technology Data Exchange (ETDEWEB)

The Los Alamos Nuclear Material Accounting and Safeguards System (MASS) is a near-real-time accountability system for bulk materials, discrete items, and material undergoing dynamic processing. MASS has evolved from an eighty-column card based process control system to a very sophisticated computer system. The security of the MASS computer system is provide through various access controls. There are two kinds of access control to be addressed. They are physical access control to the hardware which make up the system, and access control to the software. There are many features which provide a measure of security to the hardware that will be discussed. Access to the software is controlled by a security password. Access to various transaction activities in the system is controlled through the level of MASS user privilege. Details of MASS user privilege will be discussed.

1988-01-01

454

Response variability in balanced cortical networks  

DEFF Research Database (Denmark)

We study the spike statistics of neurons in a network with dynamically balanced excitation and inhibition. Our model, intended to represent a generic cortical column, comprises randomly connected excitatory and inhibitory leaky integrate-and-fire neurons, driven by excitatory input from an external population. The high connectivity permits a mean field description in which synaptic currents can be treated as gaussian noise, the mean and autocorrelation function of which are calculated self-consistently from the firing statistics of single model neurons. Within this description, a wide range of Fano factors is possible. We find that the irregularity of spike trains is controlled mainly by the strength of the synapses relative to the difference between the firing threshold and the postfiring reset level of the membrane potential. For moderately strong synapses, we find spike statistics very similar to those observed in primary visual cortex.

2006-01-01

455

Removal of 106Ru traces from NH4NO3 effluent generated during recycling of sintered depleted uranium fuel pellets  

British Library Electronic Table of Contents (United Kingdom)

Feasibility of using fixed bed column of conventional ion exchangers/sorbent and chemical precipitation based processes have been examined for the effective removal of the very low levels of 106Ru activity from NH4NO3 effluent generated during wet processing of rejected sintered depleted uranium fuel pellets. Based on the results, a simple process involving precipitation of cobalt sulphide along with ferric hydroxide was selected and further optimization of process variables was carried out. The optimized process has been found to be highly efficient in reducing 106Ru activity down to extremely low levels.

2011-01-01

456

Production of carrier free 188Re radioisotope generator based on aluminum tungstate matrix  

British Library Electronic Table of Contents (United Kingdom)

Improved radionuclide generator include a substantially insoluble salt of a radioactive parent which may be directly packed in column for subsequent elution of the daughter radionuclide. An improved 188Re generator was prepared by reacting a radioactive tungsten (188W) as parent radionuclide incorporated with aluminum chloride to obtain an insoluble radioactive aluminum tungstate matrix. The investigated matrix was characterized on the basis of the chemical composition, IR, thermal analysis and mechanical stabilities. The factors affecting the elution performance were studied such as influence of pH, molar ratio and drying temperature. From the obtained data, the molar ratio W:Al was 1.5:1 at pH?=?4, the matrix dried at 105??C for 2 h. Chromatographic and multichannel analysis has been cur...

2010-01-01

457

Prediction and measurement of the neutron environment in OSURR experimental facilities following conversion to LEU  

International Nuclear Information System (INIS)

Neutron energy spectra were measured for two OSURR experimental facilities. The method of multiple foil activation was used with the SAND-II neutron spectrum unfolding code to obtain spectral data for the Central Irradiation Facility and Rabbit tube. Limited data was obtained for the thermal column using only gold foils. Calculations were made of the neutron environment in various locations using the MORSE code. A shift towards higher neutron energies was observed comparing results for LEU and HEU cores. A slight loss in total thermal neutron flux was measured for all positions. Calculational results show reasonable agreement with measured data.

1993-07-01

458

Optimization of EB plant by constraint control  

Energy Technology Data Exchange (ETDEWEB)

Optimum plant operation can often be achieved by means of constraint control instead of model- based on-line optimization. This is because optimum operation is seldom at the top of the hill but usually at the intersection of constraints. This article describes the development of a constraint control system for a plant producing ethylbenzene (EB) by the Mobil/Badger Ethylbenzene Process. Plant optimization can be defined as the maximization of a profit function describing the economics of the plant. This function contains terms with product values, feedstock prices and operational costs. Maximization of the profit function can be obtained by varying relevant degrees of freedom in the plant, such as a column operating pressure or a reactor temperature. These degrees of freedom can be varied within the available operating margins of the plant.

1991-03-01

459

Only 3.5% of foods exceed the maximum pesticide residues level, EFSA says  

Wastenet

...5% of foods exceed the maximum pesticide residues level , EFSA says European foods are largely under the Maximum Pesticide Residues Level , according to EFSA:...5% of foods exceed the maximum pesticide residues level , EFSA says Skip to content Skip to main navigation Skip to 1st column Skip to ...5% of foods exceed the maximum pesticide residues level , EFSA says Only 3.5% of foods exceed the maximum pesticide residues level , EFSA ...says Monday, 12 July 2010 12:41 European foods are largely under the Maximum Pesticide Residues Level, according to EFSA: in 2008 only 3.5% of ...

460

Molecular structure and retention behaviour of some polycyclic aromatic and perhydroaromatic hydrocarbons on graphitized carbon black  

Energy Technology Data Exchange (ETDEWEB)

On efficient glass capillary columns packed with graphitized thermal carbon black (GTCB) the stereoisomers of aromatic and saturated tricyclic hydrocarbons are completely separated and identified. The Henry's adsorption constants of the individual isomers were determined from mixture at different temperatures. Five isomers of perhydroanthracene, five isomers of perhydrofluorene, two isomers of perhydrophenalene, four isomers of perhydroacenaphthene, as well as phenalene, dihydrophenalene, acenaphthene and acenaphthylene were investigated. The increase of the hydrogenization degree of unsaturated tricyclic hydrocarbons reduces the retention. Among the saturated tricyclic isomers the retention becomes shorter with the larger bending of the molecules, i.e. from the molecule having more equatorial bonds to the molecules having more axial connections. The experimentally determined Henry's constants were qualitatively compared with the structure of the ...

1984-04-01

461

Mechanism of the retention of ion associates of heteropoly acids with trioctylamine on a nitrile phase  

International Nuclear Information System (INIS)

The separation and the mechanism of retention of ion associates of #alpha#-isomers of molybdic and tungstic heteropoly acids (HPA) of phosphorus(5), silicon(4), and germanium(4) with trioctylamine (TOA) on a column (80x3 mm) packed with Diasorb-130-CN (8 #mu#m) were studied in a flow of chloroform-tetrahydrofuran (THF) and chloroform-n-butanol-TOA mixtures with spectrophotometric detection at 320 nm. It is demonstrated that the adsorption of all the studied ion associates proceeds through the displacement THF molecule from the surface of the stationary phase and without the displacement of TOA molecules. Conditions for the separation of phospho- and silicomolybdic HPA and also phospho- and germanolybdic HPA were found. The chromatographic system using silica gel modified with nitrile groups as the stationary phase is of higher selective than that using ummodified silica gel.

462

MCNP study for epithermal neutron irradiation of an isolated liver at the Finnish BNCT facility  

International Nuclear Information System (INIS)

A successful boron neutron capture treatment (BNCT) of a patient with multiple liver metastases has been first given in Italy, by placing the removed organ into the thermal neutron column of the Triga research reactor of the University of Pavia. In Finland, FiR 1 Triga reactor with an epithermal neutron beam well suited for BNCT has been extensively used to irradiate patients with brain tumors such as glioblastoma and recently also head and neck tumors. In this work we have studied by MCNP Monte Carlo simulations, whether it would be beneficial to treat an isolated liver with epithermal neutrons instead of thermal ones. The results show, that the epithermal field penetrates deeper into the liver and creates a build-up distribution of the boron dose. Our results strongly encourage further studying of irradiation arrangement of an isolated liver with epithermal neutron fields.

2004-11-01

463

Loading of wellbores with explosives  

Energy Technology Data Exchange (ETDEWEB)

Bags of explosive are loaded rapidly into deep wellbores by suspending a rigid positioning tube partway into the wellbore, and loading the bags into the tube, the bags being prevented from dropping through the open bottom end of the tube by a cord attached to the lowermost bag and secured at the upper end of the tube when the tube-suspending cable is in tension by a cordsecuring/releasing means, E.G., a pivotable bar having a hook on one end. When the bag-laden tube is lowered to the bottom of the wellbore, or to a column of bags previously placed therein, the tension on the cable is relaxed and the cord is released, allowing the positioning tube thereafter to be raised to the surface for re-use, leaving the cord and bags in the wellbore. Freedom of the bag-supporting cord to move with respect to the positioning tube when the latter is raised to the surface is assured by threading the cord through plastic tubing mounted to the wall of the positioning tube and ...

1983-04-26

464

Kinetics of carbon dioxide absorption in aqueous solutions of diisopropanolamine  

Energy Technology Data Exchange (ETDEWEB)

A bubble column absorber was used to investigate kinetics of the reaction between carbon dioxide and aqueous solutions of diisopropanolamine (DIPA), by means of gas absorption experiments. These were conducted in the temperature range of 10 to 40deg C, with DIPA concentrations from 5 to 500 mol/m{sup 3}, and CO{sub 2} partial pressures between 5 and 101 kPa. A model based on the Danckwerts' surface reneval theory was used to analyze the experimental results and to determine the rate constant. The obtained data support the assumption of a second-order overall reaction, with the rate constants being well correlated by the Arrhenius equation: k{sub 2} = 1.112 x 10{sup 10} exp(-4848/T). (orig.).

1992-04-01

465

Ion exchange chromatographic separation and MS analysis of isotopes of boron  

International Nuclear Information System (INIS)

Using electrochemical techniques of pH-metry and conductimetry, the choice of a suitable complexing reagent was made amongst ethylene glycol, propylene glycol, dextrose and mannitol for cost-effective separation of isotopes of boron by ion exchange chromatography. Quantitative relationships between pH and concentration; pK_a and concentration of each of these complexing reagents were determined by least square polynomial curve fitting and an attempt was made to determine the formation constants of mannitol-borate complex. The results of experiments carried out for selection; regeneration of a resin; separation factor determinations using batch as well as column techniques and monitoring of band movements using these electrochemical techniques are discussed. (author).

1997-05-18

466

Instrumented model pile tests on sand plugs  

Energy Technology Data Exchange (ETDEWEB)

0pen ended piles develop internal frictional resistance between the internal soil plug end the pile wall during axial loading. Current pipe pile design practice assumes that the ultimate internal skin friction is of the same order of magnitude as the outer skin friction. This paper describes a series of laboratory pile load tests on instrumented model pipe piles, designed to investigate the development of plug stresses and skin friction along the plug length during pile loading. The piles contain sand columns of various relative densities and of different heights. The soil plugs are loaded to failure under fully drained conditions. The test data indicate that internal skin friction in sand can be substantially higher than assumed in conventional design practice. This finding could lead to significant economical savings on future pipe pile foundations in sand.

1995-12-31

467

High-Throughput Screening of Drugs of Abuse in Urine by Supported Liquid?Liquid Extraction and UHPLC Coupled to Tandem MS  

British Library Electronic Table of Contents (United Kingdom)

A qualitative method, involving supported liquid?liquid extraction (SLE) and ultra high pressure liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS?MS), was developed for the rapid tentative identification of various drugs of abuse in urine. In this study, 28 drugs and metabolites were covered by the screening procedure. Before analysis, urine samples were extracted by SLE and good extraction recoveries were obtained for most investigated compounds. The UHPLC strategy was then selected for the rapid separation of amphetamines, cocaine, opiates and related compounds in urine. Using columns packed with sub-2??m particles, analysis time was reduced down to 2?min, while maintaining acceptable performance. Finally, the detection was by tandem MS operating in the single reaction...

2009-01-01

468

Gamma-ray spectrometric analysis of nuclides formed in thorium by neutron irradiation  

International Nuclear Information System (INIS)

Gamma-ray spectrometric analysis was employed to determine the nuclides formed in thorium by neutron irradiation. Thorium sample was irradiated by neutron from a pure thermal neutron field, neutron field of Cd ratio of about 4, and epithermal neutron field, respectively. The former irradiation was carried out in a thermal neutron column provided for medical uses of neutrons, and the latters were done in the F-ring position of TRIGA II research reactor of Musashi Institute of Technology. The gamma-ray spectra were obtained and analyzed by employing a fully automatic gamma-ray analysis system named ''GAMA: giant frog:-SYSTEM'' developped by Musashi Institute of Technology. The formation of Pa-233 (U-233) was discussed quantitatively with respect to the difference of the neutron field. (author).

1985-02-01

469

Galactic Cosmic Rays - Clouds Effect and Bifurcation Model of the Earth Global Climate. Part 1. Theory  

CERN Document Server

The possible physical linkage between galactic cosmic rays intensity and the Earth's cloud cover is discussed using the analysis of the first indirect aerosol effect (Twomey effect) and its experimental representation as the dependence of average cloud droplet effective radius on aerosol index characterizing the aerosol concentration in the atmospheric air column of unit section. It is shown that the basic kinetic equation of the Earth's climate energy-balance model is described by the bifurcation equation (with respect to the temperature of the Earth's surface) in the form of fold catastrophe with two governing parameters defining the variations of insolation and Earth's magnetic field (or galactic cosmic rays intensity in the atmosphere), respectively. The principle of hierarchical climatic models construction, which consists in the structural invariance of balance equations of these models evolving on the different time scales, is described. It means that if the ...

2008-01-01

470

Factors influencing radon attenuation by tailing covers  

Energy Technology Data Exchange (ETDEWEB)

The US NRC, in its Generic Environmental Impact Statement on uranium milling has specified that the radon flux escaping a uranium mill tailings pile will be reduced to pCi/m/sup 2/ s by application of covering layers of soils and clays. These covers present a radon diffusion barrier, which sufficiently increases the time required for radon passage from the tailings to the atmosphere to allow for decay of /sup 222/Rn within the cover. The depth of cover necessary to reduce the escaping radon flux to the prescribed level is to be determined by calculation, and requires precise knowledge of the radon diffusion coefficient in the covering media. A Radon Attenuation Test Facility was developed to determine rates of radon diffusion through candidate cover materials. This paper describes this facility and its application for determining the influence of physical properties of the soil column on the radon diffusion coefficient.

1981-07-01

471

Does external pressure explain recent results for molecular clouds?  

British Library Electronic Table of Contents (United Kingdom)

Abstract The recent paper by Heyer et al. indicates that observations of size, linewidth and column density of interstellar clouds do not agree with simple virial equilibrium (SVE) as a balance between gravitational and kinetic energies in the sense that the clouds either have too much kinetic energy or too little mass to be bound. This may be explained by violation of SVE as suggested by Dobbs et al., by observational underestimation of the masses as suggested by Heyer et al. or by an external pressure acting as an additional confining force as suggested earlier by Heyer et al. The data of Heyer et al. cannot be explained with a single value for the external pressure, but if different clouds in the sample have different external pressures in the range of Pe/k= 104-107 cm-3-K, then most of...

2011-01-01

472

Development and validation of a reference measurement procedure for certification of phenytoin, phenobarbital, lamotrigine, and topiramate in human serum using isotope-dilution liquid chromatography/tandem mass spectrometry  

British Library Electronic Table of Contents (United Kingdom)

Phenytoin (PHT), phenobarbital (PHB), lamotrigine (LTG), and topiramate (TPM) are some of the most widely used antiepileptic drugs (AEDs). Monitoring of their concentrations in serum is important for the treatment of epilepsy. A reference measurement procedure (RMP) for certification of PHT, PHB, LTG, and TPM in serum has been developed and critically evaluated. Isotopically labeled compounds of PHT, PHB, LTG, and TPM are used as internal standards for the four AEDs. The four drugs and their respective labeled internal standards are simultaneously extracted from serum using solid-phase extraction prior to reversed-phase liquid chromatography?tandem mass spectrometry (LC-MS/MS). Chromatographic separation was performed using a C18 column. Electrospray ionization (ESI) in the positive ion mo...

2011-01-01

473

Determination of some minor and trace elements in iron ores by ion exchange chromatography, spectrophotometry and atomic absorption spectrometry  

International Nuclear Information System (INIS)

A method is described for determination of aluminium, cadmium, cobalt, chromium, copper, calcium, magnesium, sodium, potassium, manganese, nickel, lead, strontium, zinc, titanium and vanadium in iron ore. After dissolution, a 1 gram sample of iron ore is applied to a column of AGI-X8 anion exchange resin (chloride form), in 100 ml of 7M HCl. Aluminium, chromium, calcium, magnesium, sodium, potassium, manganese, nickel, lead, strontium, titanium and vanadium are eluted with 7M HCl; iron, copper and cobalt are eluted with 0.5M HCl; cadmium and zinc are eluted with 2M HNO_3. Iron is subsequently removed from copper and cobalt by a solvent extraction with methyl isobutyl ketone. The elements are determined in the eluates by atomic absorption spectrometry, except for titanium and vanadium, which are determined spectrophotometrically.

474

Continuous-wave cavity ringdown spectroscopy of the Formula Not Shown Meinel system (2,1) band  

British Library Electronic Table of Contents (United Kingdom)

The Formula Not Shown system of Formula Not Shown was first observed in auroral emissions by Meinel in 1950. Although the Formula Not Shown band system has been reinvestigated since this first spectral study, no laboratory spectrum of the (2,1) vibronic band has been obtained. We have recently built a continuous-wave cavity ringdown spectrometer, and as a first test of this spectrometer we observed the (2,1) band of Formula Not Shown in a positive column discharge cell. Many lines of the first positive band system of Formula Not Shown were also identified during the process of assigning this spectrum. The relative intensities of the Formula Not Shown and Formula Not Shown bands were found to change with discharge cell pressure, and so each spectral region was observed at two pressures to a...

2008-01-01

475

Concentrations of 239+240 Pu and 137 Cs in seawater near Wolsung nuclear power plant  

Energy Technology Data Exchange (ETDEWEB)

Concentrations of {sup 239+240} Pu and {sup 137} Cs were measured for vertical direction and horizontal direction in seawater collected at 21 locations on the 8 directions near Wolsung nuclear power plant. The inventories of {sup 239+240} Pu and {sup 137} Cs were calculated in seawater column. The concentrations of {sup 239+240} Pu and {sup 137} Cs were in seawater in the range of 8-36 {mu}Bq/L, 2.4-4.5 mBq/L, respectively. The {sup 239+240} Pu concentration increased with depth, however, the {sup 137} Cs concentrations not greatly changed with depth above thermocline.

2002-05-01

476

Concentrations of 239+240 Pu and 137 Cs in seawater near Wolsung nuclear power plant  

International Nuclear Information System (INIS)

Concentrations of "2"3"9"+"2"4"0 Pu and "1"3"7 Cs were measured for vertical direction and horizontal direction in seawater collected at 21 locations on the 8 directions near Wolsung nuclear power plant. The inventories of "2"3"9"+"2"4"0 Pu and "1"3"7 Cs were calculated in seawater column. The concentrations of "2"3"9"+"2"4"0 Pu and "1"3"7 Cs were in seawater in the range of 8-36 #mu#Bq/L, 2.4-4.5 mBq/L, respectively. The "2"3"9"+"2"4"0 Pu concentration increased with depth, however, the "1"3"7 Cs concentrations not greatly changed with depth above thermocline.

2002-05-01

477

Chromatography of metal ions with a triazine chelating resin  

International Nuclear Information System (INIS)

The synthesis, characterization, and some analytical applications of a new triazine resin are described. Separation of group IB, IIB, VIB, and VIIB metal ions from group VIII metal ions is achieved by this PDT-4 resin. Calcium(II) and magnesium(II) are taken up at pH = 6, 0.1 M acetate and are eluted at pH = 6, 0.1 M sodium nitrate. Copper(II) is retained at pH = 6, 0.1 M acetate and pH = 1 hydrochloric acid and is eluted subsequently by 5 M perchloric acid. Molybdenum(VI) is sorbed selectively from 0.1 N sulfuric acid or hydrochloric acid and is eluted in a tight band by 0.1 N sodium hydroxide. Numerous rapid column chromatographic separations are reported using this new resin, including analysis of NBS standard samples.

478

CHEMICAL TECHNOLOGY DIVISION. UNIT OPERATIONS SECTION MONTHLY PROGRESS REPORT, FEBRURARY 1963  

Science.gov (United States)

Development of a shear and leach complex for UO/sub 2/-SS clad fuel was continued with major emphasis on the operation of a rotary drum leacher. Flooding data for nozzle plate pulse columns at high A/O ratios are reported. Engineering tests of dissolution of Zr--6% U alloy with HF in molten salt demonstrated a dissolution rate of 0.8 to 1.5 mg/cm/sup 2//min. Subsequent fluorination with 100% F/sub 2/ proceeded at half times of 40 to 135 min. The results of a high level waste calcination (run R-72) made with formaldehyde treated simulated Purex waste are reported. (auth)

1963-10-01

479

Biosorption of lead from aqueous solutions by Bacillus strains possessing heavy-metal resistance  

British Library Electronic Table of Contents (United Kingdom)

In this study, bacterial strains were investigated in order to determine their heavy metal tolerance. The bacterial strains were identified as Bacillus cereus and Bacillus pumilus. In the batch system, the effects of operating variables such as solution pH, initial metal concentration, contact time, and adsorbent dosage were investigated. Both isolates were highly resistance to copper and lead in comparison with the control strain examined. The adsorption capacities of B. cereus and B. pumilus were found to be 22.1mg/g and 28.06mg/g, respectively. The biosorption follows pseudo-second order kinetics and the isotherm fits well to the Langmuir isotherm model. In column experiments, the biosorption was fitted well by the Thomas model. The breakthrough and exhaustion capacity of each biosorben...

2011-01-01

480

Asymmetric Totally-corrective Boosting for Real-time Object Detection  

CERN Document Server

Real-time object detection is one of the core problems in computer vision. The cascade boosting framework proposed by Viola and Jones has become the standard for this problem. In this framework, the learning goal for each node is asymmetric, which is required to achieve a high detection rate and a moderate false positive rate. We develop new boosting algorithms to address this asymmetric learning problem. We show that our methods explicitly optimize asymmetric loss objectives in a totally corrective fashion. The methods are totally corrective in the sense that the coefficients of all selected weak classifiers are updated at each iteration. In contract, conventional boosting like AdaBoost is stage-wise in that only the current weak classifier's coefficient is updated. At the heart of the totally corrective boosting is the column generation technique. Experiments on face detection show that our methods outperform the state-of-the-art asymmetric boosting methods.

2010-01-01

481

Assessment of different protocols for the isolation and purification of gut associated lymphoid cells from the gilthead seabream (Sparus aurata L.)  

British Library Electronic Table of Contents (United Kingdom)

Teleost gut associated lymphoid tissue (GALT) consists of leucocyte populations located both intraepithelially and in the lamina propria with no structural organization. The present study aims to assess different protocols for the isolation of GALT cells from an important fish species in the Mediterranean aquaculture, the gilthead seabream. Mechanical, chemical and enzymatic treatments were assayed. Nylon wool columns and continuous density gradients were used for further separation of cell subpopulations. Light microscopy and flow cytometry showed that the highest density band (HD) consisted of a homogeneous lymphocytic population, whereas the intermediate density band (ID) corresponded to epithelial and secretory cells and some lymphocytes. Respiratory burst activity of total cell suspen...

2007-01-01

482

Applications of CR-39 for the estimation of biological effects of heavy ion irradiation to DNA and living cells  

Energy Technology Data Exchange (ETDEWEB)

We present two applications of CR-39 to estimate biological effects of heavy ion irradiation. The accurate measurement of fluence of ions using CR-39 is indispensable to calculate the action cross sections for biological effects. Ions with 6 MeV/n at the Medium Energy Beam Course, HIMAC (NIRS) were extracted to the air, and degraded with the air. DNA and living cells were irradiated by ions with various specific energies at several air columns along with the Bragg curve. DNA strand breaks and cell killing were measured and the results were converted to the action cross sections using the fluence measured with CR-39 at the irradiation positions. Another example of the application of CR-39 is to identify whether the ions with a specific energy pass through the cell or stop within the cell. (author)

2001-10-01

483

Antioxidant properties of chlorophyll-enriched and chlorophyll-depleted polyphenolic fractions from leaves of Vernonia amygdalina and Gongronema latifolium  

British Library Electronic Table of Contents (United Kingdom)

This study investigated the optimum polyphenol extraction conditions for two Nigerian green leafy vegetables, Vernonia amygdalina (VA) and Gongronema latifolium (GL) that are widely used for food and medicinal purposes. Seven different solvents were used to extract the total phenolic contents of the leaves; 100% acetone, 80% acetone, 50% acetone, 100% ethanol, 70% ethanol, 100% methanol and 70% methanol and their total phenolic contents were determined. The results showed that the 80% acetone was significantly (p<0.05) the most effective for polyphenol extraction from the leaves and generally the acetone-containing solvents were more effective than alcohol-containing solvents. The 80% acetone extract was fractionated on a silicic acid-packed column to give two main fractions: acetone elute...

2011-01-01

484

Adsorption of Pb^2^+ and Zn^2^+ from aqueous solutions by sulfured orange peel  

British Library Electronic Table of Contents (United Kingdom)

In this study, sulfured orange peel (MOP) was used as adsorbent to investigate its adsorption behaviors of Pb^2^+ and Zn^2^+ from aqueous solutions. The effects of solution pH, adsorption time and metal ion concentration on adsorption were studied in batch experiments. Both adsorption kinetics of Pb^2^+ and Zn^2^+ proceeded rapidly and could be well described by pesudo-second-order equation. The maximum Langmuir adsorption capacities for Pb^2^+ and Zn^2^+ removal by MOP were evaluated as 164 and 80mg/g, respectively. A binary mixture of Pb^2^+ and Zn^2^+ was studied by using a packed column, suggesting that effective mutual separation and pre-concentration of Pb^2^+ away from Zn^2^+ using MOP could be satisfactory achieved. The results indicate that MOP could be employed as an effective lo...

2011-01-01

485

Adsorption of Db and its homologues Nb and Ta, and the pseudo-homologue Pa on anion-exchange resin in HF solution  

Energy Technology Data Exchange (ETDEWEB)

Anion-exchange chromatography of element 105, dubnium (Db), produced in the {sup 248}Cm({sup 19}F, 5n){sup 262}Db reaction is investigated together with the homologues Nb and Ta, and the pseudo-homologue Pa in 13.9 M hydrofluoric acid (HF) solution. The distribution coefficient (K{sub d}) of Db on an anion-exchange resin is successfully determined by running cycles of 1702 chromatographic column separations. The result clearly indicates that the adsorption of Db on the resin is significantly different from that of the homologues and that the adsorption of anionic fluoro complexes of these elements decreases in the sequence of Ta{approx}Nb>Db{>=}Pa. (orig.)

2009-07-01

486

Adsorption of Db and its homologues Nb and Ta, and the pseudo-homologue Pa on anion-exchange resin in HF solution  

International Nuclear Information System (INIS)

Anion-exchange chromatography of element 105, dubnium (Db), produced in the "2"4"8Cm("1"9F, 5n)"2"6"2Db reaction is investigated together with the homologues Nb and Ta, and the pseudo-homologue Pa in 13.9 M hydrofluoric acid (HF) solution. The distribution coefficient (K_d) of Db on an anion-exchange resin is successfully determined by running cycles of 1702 chromatographic column separations. The result clearly indicates that the adsorption of Db on the resin is significantly different from that of the homologues and that the adsorption of anionic fluoro complexes of these elements decreases in the sequence of Ta#approx#Nb>Db#>=#Pa. (orig.)

487

A tomography system at the thermal neutron column of the ENEA Casaccia TRIGA reactor  

Energy Technology Data Exchange (ETDEWEB)

The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10{sup 6} n/cm{sup 2} s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)

2002-07-01

488

A tomography system at the thermal neutron column of the ENEA Casaccia TRIGA reactor  

International Nuclear Information System (INIS)

The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10"6 n/cm"2 s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)

489

A report on the CCNA 2007 professional practice analysis.  

Science.gov (United States)

The purpose of this column is to present the results of the 2007 Professional Practice Analysis (PPA) of the field of nurse anesthesia, conducted by the Council on Certification of Nurse Anesthetists. The PPA used survey and rating scale methodologies to collect data regarding the relative emphasis of various aspects of the nurse anesthesia knowledge domain and competencies. A total of 3,805 survey responses were analyzed using the Rasch rating scale model, which aggregates and transforms ordinal (rating scale) responses into linear measures of relative importance and frequency. Summaries of respondent demographics and educational and professional background are provided, as well as descriptions of how the survey results are used to develop test specifications. The results of this analysis provide evidence for the content outline and test specifications (content percentages) and thus serve as a basis of content validation for the National Certification Examination. ...

2009-06-01

490

A nontoxic antitumour compound from the leaves of Bauhinia scandens characterized as 1-O-alkyl glycerol by gas-liquid chromatography and evaluation of its antitumour property by Brine Shrimp bioassay  

British Library Electronic Table of Contents (United Kingdom)

This is a report of extraction and identification of 1-O-alkyl glycerol present in the dried leaves of Bauhinia scandens. Fifty percent aqueous ethanolic extract of the plant at room temperature was fractionated over petroleum ether and diethyl ether. The diethyl ether soluble fraction showed positive bioactivity in Brine Shrimp bioassay. Isolation and purification of the active principle was subsequently done from diethyl ether fraction. The diethyl ether fraction was separated into acidic and neutral part. The acid free fraction was screened to be positive in Brine Shrimp bioassay. The NMR spectra (in CDCl3) indicated the probability of its lipoidal nature. The total lipid fraction was resolved into neutral, glyco, and phospho-lipids by column chromatography. Only the neutral fraction sh...

2008-01-01

491

A high-performance liquid chromatography-based radiometric assay for sucrose-phosphate synthase and other UDP-glucose requiring enzymes  

Energy Technology Data Exchange (ETDEWEB)

A method for product analysis that eliminates a problematic step in the radiometric sucrose-phosphate synthase assay is described. The method uses chromatography on a boronate-derivatized high-performance liquid chromatography column to separate the labeled product, (14C)sucrose phosphate, from unreacted uridine 5{prime}-diphosphate-(14C)glucose (UDP-Glc). Direct separation of these compounds eliminates the need for treatment of the reaction mixtures with alkaline phosphatase, thereby avoiding the problem of high background caused by contaminating phosphodiesterase activity in alkaline phosphatase preparations. The method presented in this paper can be applied to many UDP-Glc requiring enzymes; here the authors show its use for determining the activities of sucrose-phosphate synthase, sucrose synthase, and uridine diphosphate-glucose pyrophosphorylase in plant extracts.

1991-05-01

492

The use of oxygen isotopic composition to study water dynamics in Amazon floodplain lakes  

International Nuclear Information System (INIS)

The lakes formed in the Amazon floodplain play a key role in sustaining the highest populational density in the Amazon Basin because of its high primary productivity. The water volume in these lakes vary greatly during the year and possible water sources are the feeding river during high water state of the hydrographs and local inputs from its drainage basin. As these sources are chemically distinct, to understand the nutrient dynamics in these lakes, it is very important to know the relative water contribution of different water sources. In this paper we use "1"8O as a conservative to know the water sources for the lakes and our hypothesis is that: 1) In the high water stage lake water is derived predominantly from its feeding river. Therefore their #delta#"1"8O should be similar. 2) In the low ...

1989-05-01

493

Water demand management in areas of ground water over-exploitation  

Environmental Research Database

SummaryIntended Outputs: Identification and evaluation, using participatory approaches, of demand management options:*Technical*Allocative and market based*Impact on target beneficiariesSupporting measures required when introducing water demand management options above:*Extension services & training*Water licences/rights*Institutional changes*Legal measures and regulation*Education*Support in diversifying to less water demanding activities*S [continued...]ObjectivesIdentification of the most appropriate demand management strategies for ground water abstraction, where aquifiers are being over-exploited, ensuring sustainable livelihoods of the vulnerable and poor are safeguarded. Poverty reduction strategies for areas where groundwater is being over-exploited.DescriptionProject Background: Groundwater is the principal source of both irrigation and domestic water supplies in many ...

2006-01-15

494

Water consumption during solid state sodium borohydride hydrolysis  

Energy Technology Data Exchange (ETDEWEB)

In this paper nickel acetate catalyzed sodium borohydride cartridges have been prepared and hydrolyzed with water for hydrogen production. Two technological solutions have been tested to increase the overall hydrogen yield, namely a porous water diffuser and a hydrophobic membrane. The first was used to improve water diffusion inside the hydride while the second to confine water inside the cartridge. The generated hydrogen flow showed a very reproducible behavior. Hydrogen promptly evolved just after water was pumped into the cartridge. After some initial peaks, a constant hydrogen flow has been recorded for the whole reaction time. The constant flow was related to the presence of the porous diffuser. The use of a hydrophobic membrane to confine the water inside the cartridge allowed to increase the overall hydrogen yield: about 6 water ...

2010-11-15

495

Phytoplankton primary production in a eutrophic cooling water pond  

Energy Technology Data Exchange (ETDEWEB)

The effect of longer ice-free periods on the seasonal variation and total annual values of phytoplankton primary production was considered along with the efficiency and productivity of the phytoplankton communities at different water temperatures by constant light. The studied pond, Vasikkalampi, is located in the town Jvyaskyla in central Finland. The pond is slightly eutrophic and its water is used for cooling purposes by a 35 MW thermal powerplant. The cooling water is taken in the middle of the pond and it returns as heated effluent to the northern part, near the surface, about 100 m from the intake pipe. This circulation and warming of the water keeps the pond open throughout the year except during the coldest weeks in the winter when some parts freeze over. The increase of the water temperature was not sufficient to be optimal for photosynthesis in the spring. The ...

1984-01-01

496

Natural radionuclides in drinking water in Argentina  

International Nuclear Information System (INIS)

As part of the national survey to evaluate natural radioactivity in the environment, concentration levels of natural uranium and "2"2"6Ra have been analyzed in over 300 drinking water samples taken from different locations in Argentina. "2"2"6Ra was determined by "2"2"2Rn emanation and liquid scintillation counting, and natural uranium by a fluorimetric procedure. Values ranging from 0.03 to 24 #mu#g.l"-"1 of natural uranium and from 0.06 to 50 #mu#g.l"-"1, were measured on drinking water samples taken from tap water systems and private wells, respectively. Concentrations up to 15 mBq.l"-"1 and to 22 mBq.l"-"1 of "2"2"6Ra were found in drinking water samples taken from tap water systems and private wells, respectively. These values are compared with the reference values accepted for drinking water. Based on the water intake rate, the age ...

2000-05-01

497

Climate change and water resources in Britain  

International Nuclear Information System (INIS)

This paper explores the potential implications of climate change for the use and management of water resources in Britain. It is based on a review of simulations of changes in river flows, groundwater recharge and river water quality. These simulations imply, under feasible climate change scenarios, that annual, winter and summer runoff will decrease in southern Britain, groundwater recharge will be reduced and that water quality - as characterised by nitrate concentrations and dissolved oxygen contents - will deteriorate. In northern Britain, river flows are likely to increase throughout the year, particularly in winter. Climate change may lead to increased demands for water, over and above that increase which is forecast for non-climatic reasons, primarily due to increased use for garden watering. These increased pressures on the water resource base will ...

1998-05-01

498

Radon concentrations in well water in Sichuan Province, China  

International Nuclear Information System (INIS)

There are 110 million people in Sichuan Province, China. Although most of the people in cities of Sichuan use river water, which contains low levels of radon, as potable water, people in countryside and in some communities of big cities still use well water as domestic consumption. This paper reports the radon concentrations in well water investigated in four cities, i.e. Chengdu, Chongqing, Leshan and Leijiang in Sichuan Province. Of the 80 wells investigated, the radon concentrations range from 3.5 to 181.6 KBqm"-"3. Of the four cities, Chongqing has the highest well water radon concentration with the average 49.6 #+-# 54.1 KBqm"-"3 and the greatest variation. The investigation in four cities showed that the radon concentrations in well water are much higher than that in tap-water. In Chongqing where there are complex geological ...

499

EDI as a Treatment Module in Recycling Spent Rinse Waters  

Energy Technology Data Exchange (ETDEWEB)

Recycling of the spent rinse water discharged from the wet benches commonly used in semiconductor processing is one tactic for responding to the targets for water usage published in the 1997 National Technology Roadmap for Semiconductors (NTRS). Not only does the NTRS list a target that dramatically reduces total water usage/unit area of silicon manufactured by the industry in the future but for the years 2003 and beyond, the NTRS actually touts goals which would have semiconductor manufacturers drawing less water from a regional water supply per unit area of silicon manufactured than the quantity of ultrapure water (UPW) used in the production of that same silicon. Achieving this latter NTRS target strongly implies more widespread recycling of spent rinse waters at semiconductor manufacturing sites. In spite of the fact that, by most ...

1999-08-11