Development of a geothermal heat pump. Final report
Energy Technology Data Exchange (ETDEWEB)
In the development of a geothermal heat pump a water source heat pump was connected to a 1-1/2'' water line, 2200' long, buried in an endless loop 10' deep. The system is closed, circulating the same water continuously through the heat pump back to the field again. This water line 10' deep is the geothermal heat source. No matter how cold the air temperature gets on a winter day the water temperature to the heat pump will always be above 45/sup 0/F. This system has efficiently heated our house the past year using no supplemental heat.
1981-11-02
Binary heat pump system. Binary heat pump system
Energy Technology Data Exchange (ETDEWEB)
This technical report describes an outline, features, total energy efficiency, and specifications of binary heat pump system. A closed circuit distributed water heat source heat pump method is employed in the binary heat pump system. Since the circulating water, which is adjusted at a constant temperature, is used as the heat source of the indoor unit, a stable performance can be obtained regardless of outside atmospheric temperature. The binary heat pump system is mainly composed of a center heat pump unit, indoor heat pump unit, heat source water pipes, and circulating pump. The center heat pump unit and the indoor heat pump unit are connected with each other by the heat source ...
1993-11-30
Failure analyses and weld repair of boiler feed water pumps
Energy Technology Data Exchange (ETDEWEB)
During a regular inspection of the Boiler Auxiliaries at one of the Dutch Electricity Production Companies serious cracks were found in the cover and casings of the feed water circulation pumps in two units after 108.000 and 122.000 hours of boiler operation. Kema Laboratories carried out Failure analyses on boat samples at the cracked areas. Corrosion fatigue cracking was found on the inner side of the GS-24CrNiMo325 casing. Shop Weld repairs were carried out using a newly developed mechanized Plasma Welding Technique. The repaired feed water circulation pumps showed no problems alter several years of operation. The costs of repair were substantially lower than the costs of replacement. (orig.) 3 refs.
1998-12-31
The SBWR (simplified boiling water reactor) thermal-hydraulic performance analysis and testing
Utility interest has recently increased in potential future nuclear units that combine the characteristics of smaller size, greater simplicity, and more passive safety features. In response to such interest, General Electric (GE) began development in 1982 of a 600-MW(electric) reactor with simplified power generation and safety systems. This paper provides an overview of the simplified boiling water reactor (SBWR) design, with emphasis on the thermal-hydraulic aspects of the design. The SBWR is a natural circulation reactor requiring no pumps to circulate the water through the core.
1989-11-01
The thermal response of an infinite line of open loop wells for ground coupled heat pump systems
British Library Electronic Table of Contents (United Kingdom)
Ground thermal energy storage is a means of storing thermal energy underground during the summer and utilizing it during the winter. The main use of such a technology is in the heating, ventilating and air conditioning sector where the ground provides a stable temperature reservoir for a heat pump system. Heat pumps are mechanical systems that provide heating to a space in the winter, and cooling in the summer. They are increasingly popular because the same system provides both heating modes, depending on the direction of the cycle upon which they operate. The stable temperature reservoir allows the heat pump system to run at a higher efficiency. Thermal energy is transmitted to and from the ground by circulation of water through standing column geothermal wells. In commercial applications...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
In this paper we provide a geochemical investigation on 34 groundwater samples in the Mt. Vulture volcanic aquifer representing one of the most important groundwater resources of the southern Italy pumped for drinking and irrigation supply. The present study includes the first data on the abundance and mobility of minor and trace elements and the thermodynamic considerations on water-rock interaction processes in order to evaluate the conditions of alkali basalt weathering by waters enriched in magma-derived CO2. The results highlight the occurrence of two hydrofacies: bicarbonate alkaline-earth and alkaline waters deriving from low-temperature leaching of volcanic rocks of Mt. Vulture, and bicarbonate-sulfate-alkaline waters (high-salinity waters) related to prolonged water circulation in...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The heating system of the `Centre integre de mecanique industrielle de la Chaudiere`, in Saint-Georges, Quebec, is based on a solar wall and a geothermal heat pump with a glycol/water mixture circulating in 44 wells that are 100 m deep. With installation costs below $25 per sq.m, more than 85 per cent of the heating needs of the 9500 sq.m centre were supplied by geothermal power. The geothermal heat pump is composed of a well field and two 211-kW cooling units, each equipped with four coiled compressors. In winter, heat is pumped from the earth and in summer, a heat exchanger with control valves allows to heat to be dumped back into the earth. The monitoring and simulation of the system proved its efficiency, considering the climatic conditions in Quebec. The annual consumption of geothermal heating is 0.146 GJ per sq.m, which is very low compared to the consumption of electric ...
1996-12-01
Energy Technology Data Exchange (ETDEWEB)
A geothermal heat pump-assisted heating system is introduced into Changchun City and a survey is conducted to determine if the system may be popularized in this extremely cold region located in the northeastern part of China. In concrete terms, the hot water that circulates through the office building of Changchun Ground Heat Development Co., Ltd., is switched to hot water prepared by a geothermal heat pump. The test continued from December 2000 to March 2001. It is then concluded that heating by geothermal heat pumps will be fully serviceable to Changchun City. Implemented are (1) the shift from the coal fired boiler system to a geothermal heat pump system comprising 16 subterranean heat exchangers for the heating of the office building which is approximately 1000 m{sup 2} large, (2) long-term monitoring of the operating conditions, (3) ...
2001-03-01
New technology for purging the steam generators of nuclear power plants
British Library Electronic Table of Contents (United Kingdom)
A technology for removal of undissolved impurities from a horizontal steam generator using purge water is developed on the basis of a theoretical analysis. A purge with a maximal flow rate is drawn off from the zone with the highest accumulation of sludge in the lower part of the steam generator after the main circulation pump of the corresponding loop is shut off and the temperatures of the heat transfer medium at the inlet and outlet of the steam generator have equilibrated. An improved purge configuration is used for this technology; it employs shutoff and regulator valves, periodic purge lines separated by a cutoff fixture, and a D y 100 drain union as a connector for the periodic purge. Field tests show that the efficiency of this technology for sludge removal by purge water is severa...
2011-01-01
Effects of Convective Hydraulic Circulation on Phosphorus ...
... For other aquatic systems, detailed diel observations of both water temper- ature and periods of flow will be necessary to estimate convective ...
1993-02-01
Energy Technology Data Exchange (ETDEWEB)
Using the past diffusion trends of four renewable energy technologies for irrigation water pumping in India (SPV pumps, windmill pumps and biogas/producer gas driven dual fuel engine pumps), results of an attempt to project their future dissemination levels, have been presented in this study. The likely contribution of the renewable energy options considered in the study to the projected energy demand for irrigation water pumping in India has been estimated. Estimates of the associated investment requirements taking into account the learning effect have also been presented. (author)
2005-12-01
Rural residential application of geothermal heat pump. Progress report
Energy Technology Data Exchange (ETDEWEB)
The installation and performance of a water source heat pump in Minnesota are discussed. The operating cost was found to be higher than expected. (MHR)
1981-07-20
Energy Technology Data Exchange (ETDEWEB)
Simple frameworks have been developed for estimating the utilization potential of: (a) solar photovoltaic (SPV) pumps; (b) windmill pumps; (c) producer gas based dual fuel engine pumps; and (d) biogas based dual fuel engine pumps for irrigation water pumping in India. The approach takes into account factors such as: solar radiation intensity, wind speed, availability of bovine dung and agri-residues, and their alternative uses, ground water requirements for irrigation and its availability, affordability, and propensity of the users to invest in renewable energy devices, etc. SPV pumps are estimated to have the maximum utilization potential in India, followed by windmill pumps. (author)
2007-05-15
Potential for hot-dry-rock geothermal resources: experimental results
Hot dry rock (HDR) contains insufficient permeability and fluid for natural hydrothermal development, but water pumped in a circulation loop through a HDR reservoir (hydraulically fractured between two drill holes) is being tested and evaluated. The formation of such in situ heat transfer systems, and subsequent testing of the man-made geothermal reservoirs in the Jemez volcanic field, New Mexico have already indicated the technical feasibility of the hot dry rock (HDR) geothermal concept. Documented production history and heat-extraction data obtained during the period from 1978 to 1980 have confirmed heat transfer, low water loss, and predictable thermal drawdown models for the HDR systems. During a nine month test of closed-loop heat extraction operations, 15 x 10/sup 6/ kWh of thermal energy were produced. The effective heat-transfer area and volume of the reservoir increased due to secondary ...
1982-01-01
Dynamics and developing of natural circulation cooling from vertical upflow and downflow conditions
International Nuclear Information System (INIS)
Several research programs have been conducted to evaluate the capability of natural circulation cooling of reactors following a loss of cooling accident. Both experimental and RELAP5 simulation results were obtained for these studies in a facility with vertical heated tube(s) and a unheated bypass channel. The analytical results showed that, under a certain power level, a natural circulation pattern can be developed from both initial upflow and downflow conditions, and maintained for a significant cooling period. This power level, for the discussion of this paper, is defined as the natural circulation cooling (NCC) power limit. Two import factors, namely the pump coastdown rate and the initial flow direction, are examined in this paper. In the benchmark case, as compared to the experimental results, the RELAP5 simulation program accurately predicted the transient phenomena from forced convection through ...
1994-04-05
Natural circulation cooling in US Pressurized Water Reactors
International Nuclear Information System (INIS)
This document is a synthesis of data and analysis concerning natural circulation cooling in US Pressurized Water Reactors during off-normal operation and accident transients. Its objective is the integration of important research findings concerning PWR natural circulation phenomena into a single reference document. Sources of information include the Nuclear Regulatory Commission, reactor vendors, utility sponsored research groups, utilities, national laboratories, research reports, meeting papers, archival literature, and foreign sources. Three modes of natural circulation are discussed: single-phase, two-phase, and reflux/boiling condensation. General characteristics, analytical expressions, noncondensible gas effects, secondary effects, and nonuniform flow are described with regard to each of the natural circulation modes. Plant operational data, tests in scaled experimental ...
International Nuclear Information System (INIS)
In nuclear power plant Paks, Hungary, alkaline oxidative (NaOH, KMnO_4, H_2O) and acidic reductive (citric- and oxalic acid, water) liquids are using for the decontamination of primary circuit equipment (main liquid circulating pumps, steam generators, pipelines etc). The above mentioned decontamination liquids are containing "1"1"0"mAg, "9"5Nb, "5"4Mn, "5"8 Co, "6"0Co, "5"1 Cr, "1"2"4 Sb radioisotopes, summarized radioactivity is between 10"3-8x10"4 kBq/dm"3 liquid. The decontamination liquid can be cleaned with reactive adsorption (active carbon) and ion-exchange process at elevated temperature (333-368 K) in multilayered columns. After purification the summarized radioactivity for "5"4Mn, "6"0Co, and "1"1"0"mAg are in the outlet liquid below 1 kBq/dm"3. Decontamination factor DF#approx =#10"3-10"4, volumetric reduction factor VRF#approx =#50-500.
1999-11-04
International Nuclear Information System (INIS)
The circulating cooling water flowrate of GNPS and LNPS is totally about 190 m"3/s. Both stations are located on the western coast of semi-closed Daya Bay. A lot of studies concerning thermal impact of GNPS and LNPS have been carried out since 1987, including mathematical model, physical model, on-site survey and satellite remote sensing, etc. This paper describes the hydrological features of Daya Bay and discharge characteristics of circulating water of GNPS and LNPS, estimates the actual thermal impact of GNPS and LNPS, and indicates that it is advantageous for the dilution of circulating water while the two discharge channels of GNPS and LNPS are combined together towards east
2004-05-01
Model tests on a semi-axial pump turbine
Energy Technology Data Exchange (ETDEWEB)
Due to their good hydraulic characteristic semi-axial pump turbines are used in the medium head range of pumped storage plants. This paper describes model tests performed on a semiaxial pump turbine model and shows the results of these tests. The aim of the model tests was the optimization of the hydraulic water passage, the measurement of the hydraulic characteristics over the whole operating range, the investigation of the cavitation behaviour, the investigation of the hydraulic forces and torques as well as the proof of the values guaranteed to the customer.
1984-03-01
International Nuclear Information System (INIS)
Purpose: To obtain stabilized operation by preventing over heat in emergency cooling pumps upon accidents of flow regulators. Constitution: A pressure suppression chamber pool and a pressure vessel are communicated to each other with a pipeway and the water in the suppression pool is charged by a charging pump to the pipeway. The pipeway is interposed with an emergency cooling pump so as to feed water in the pipeway to the pressure vessel and a water source and the emergency cooling pumps are connected by way of a closed pipeway. Further, the closed pipeway and the pipeway interposed with the charging pump are communicated to each other by way of a connecting pipeway, to which are interposed an instrument for detecting the increase in the temperature of the emergency cooling pumps due to abnormality ...
Electrohydrodynamic pumping in cable pipes. Final report
Energy Technology Data Exchange (ETDEWEB)
Many oil-insulated electric power cables are limited by heat buildup caused in part by the low thermal conductivity of the oil. Circulation of the oil is known to reduce the cable temperature, but can lead to excessive pressure buildup on long cables when using conventional pumping methods. An alternate pumping method using distributed electric fields to avoid this pressure buildup is described. Electrohydrodynamic (EHD) pumping was studied both theoretically and experimentally for possible application in underground cable cooling. Theoretical studies included both analytical and finite-element analysis of the flow patterns driven by travelling electric fields. Experimentally, flow rates in a cable-pipe model were measured under a wide variety of operating conditions. Theory and experiment are in agreement for velocities below 10 cm/s, but higher velocities could not be reached in the experiment, due to ...
1983-02-01
Energy Technology Data Exchange (ETDEWEB)
Ground water ranging in temperature from only 38/sup 0/ to 140/sup 0/F can supply a considerable amount of heat energy when couple with a geothermal or ground-water heat pump. The heat pump's method of operation is examined as well as its performance characteristics. (MHR)
1982-12-01
Pumped storage plants 20 are a relatively common type.They use a dam to create an upper reservoir ...Some pumped storage plants use the same water turbine and electric generator for both operating periods.That is,
Pumped storage plants are a relatively common type.They use a dam to create an upper reservoir ...Some pumped storage plants use the same water turbine and electric generator for both operating periods.
Cause analysis of cracks in circulating water culvert of Daya Bay Nuclear Power Station
International Nuclear Information System (INIS)
In view of the widespread cracks discovered in the reinforced-concrete circulating water culvert of Daya Bay Nuclear Power Station, cause analysis for the cracks is made in terms of construction and design. It is concluded that the cracks mainly resulted from shrinkage and temperature. Corresponding countermeasures are put forward thereafter for reference of similar projects
2000-06-01
Energy Technology Data Exchange (ETDEWEB)
In an electromagnetic pump of the present invention for use in circulation of coolants in an LMFBR type reactor, the outer circumference of coil conductors is covered by an insulator retaining cover, and powdery or granular insulator is filled between the coil conductors and the insulator retaining cover. Upon reaching high temperature, elongation of the coil conductors by heat expansion is absorbed by movement of the particles of the powdery insulator thereby preventing excess stresses from exerting on the coil insulator constituted with the insulator retaining cover and the powdery or granular insulator and preventing generation of crackings on the coil insulator. Thus, plant stability is improved. (N.H.).
1994-05-13
High-efficiency pump for space helium transfer. Final Technical Report
Energy Technology Data Exchange (ETDEWEB)
A centrifugal pump was developed for the efficient and reliable transfer of liquid helium in space. The pump can be used to refill cryostats on orbiting satellites which use liquid helium for refrigeration at extremely low temperatures. The pump meets the head and flow requirements of on-orbit helium transfer: a flow rate of 800 L/hr at a head of 128 J/kg. The overall pump efficiency at the design point is 0.45. The design head and flow requirements are met with zero net positive suction head, which is the condition in an orbiting helium supply Dewar. The mass transfer efficiency calculated for a space transfer operation is 0.99. Steel ball bearings are used with gas fiber-reinforced teflon retainers to provide solid lubrication. These bearings have demonstrated the longest life in liquid helium endurance tests under simulated pumping conditions. Technology developed in the project ...
1991-12-01
Financial evaluation of renewable energy technologies for irrigation water pumping in India
International Nuclear Information System (INIS)
An attempt to develop a simple framework for financial evaluation of renewable energy technologies (RETs) such as photovoltaic (PV) pump, windmill pump, biogas and producer gas-driven dual fuel engine pumps for irrigation water pumping has been made. The unit cost of water and unit cost of useful energy delivered by the RETs have been estimated. The monetary benefits that accrued to the end-user have been quantified in terms of the amount of diesel or electricity saved. Financial figures of merit for the investments made in the RETs have been estimated. The effect of fuel price escalation on these measures of financial performance has also been evaluated along with the estimation of the break-even prices of fuels likely to be substituted by RETs. Results of some exemplifying calculations are presented and briefly discussed.
2007-06-01
Analysis of reverse flow in inverted U-tubes of steam generator under natural circulation condition
International Nuclear Information System (INIS)
In this paper, we report on the analysis of reverse flow in inverted U-tubes of a steam generator under natural circulation condition. The mechanism of reverse flow in inverted U-tubes of the steam generator with natural circulation is graphically analyzed by using the full-range characteristic curve of parallel U-tubes. The mathematical model and numerical calculation method for analyzing the reverse flow in inverted U-tubes of the steam generator with natural circulation have been developed. The reverse flow in an inverted U-tube steam generator of a simulated pressurized water reactor with natural circulation in analyzed. Through the calculation, the mass flow rates of normal and reverse flows in individual U-tubes are obtained. The predicted sharp drop of the fluid temperature in the inlet plenum of the steam generator due to reverse flow agrees very well with the experimental ...
2008-12-01
Device for controlling water supply to nuclear reactor
International Nuclear Information System (INIS)
Object: To smoothly control automatic water supply for realizing stable operation of a nuclear reactor by providing a flow rate limiting signal selection circuit and a preferential circuit in a water supply control device for a nuclear reactor wherein the speed of a recirculation pump may be changed in two-steps. Structure: Opening angle signals for a water supply regulating valve are controlled by a nuclear reactor water level signal, a vapor flow rate signal and a supplied water flow rate signal through an adder and an adjuster in response to a predetermined water level setting signal. When the water in the reactor is maintained at a predetermined level, a selection circuit receives a water pump condition signal for selecting one of the signals from a supplied ...
Feedwater control device for a reactor
International Nuclear Information System (INIS)
Purpose: To stably control the reactor water level so as not to cause excess water feeding in a BWR type reactor. Constitution: A flow control valve is disposed to the exit of a feedwater pump for a nuclear reactor and the valve is controlled by a flow regulator to maintain the water level constant in the reactor. A signal from a water level controller is inputted to the flow regulator to thereby control the flow rate control valve. In this case, the flow regulator remains in a saturated state just after the starting of the feedwater pump, in which the pump flowrate is at 100% to result in an excess water feeding condition. In view of the above, a feedback circuit is provided to the flow regulator so that the saturated state is eliminated and the water feeding can be controlled directly from the ...
1981-11-12
Geodesy problems in nuclear power plant construction
Energy Technology Data Exchange (ETDEWEB)
The special geodetic problems encountered during the construction of the Paks nuclear power plants are treated. The main building with its hermetically connected components including the reactor, the steam generators, the circulation pumps etc. impose special requirements on the control net of datum points. The geodesy tasks solved during the construction of the main building are presented in details.
1981-01-01
Program plan for development of underground hydroelectric pumped storage technology
The Underground Hydroelectric Pumped Storage (UHPS) Program Plan describes in detail the planned activities and expected accomplishments in the conduct of UHPS technology development and validation envisioned in the 1976 to 1990 time frame. This document describes the program objectives, implementation strategy, and management methodology. The concept of underground hydroelectric pumped storage is fully directed to application in the electric utility industry. This technology involves using electrical energy generated by base-load plants during off-peak load periods to drive a high-head pump/turbine which pumps water from a lower reservoir to a substantially elevated (upper) reservoir corresponding to a head of 1000 m or so. The upper reservoir is at ground level and the lower reservoir is below ground. Then, during peak-load periods, water in the upper ...
1976-03-01
International Nuclear Information System (INIS)
Tata Electric Companies (TEC) are engaged in the generation of hydro and thermal energy. TEC, to minimise backing down of its thermal units in off peak hours and also to at least partially meet the growing deficit in the supply during peak hours is moving to install pumped storage plants (PSPs) utilising off-peak surplus energy for pumping the water from lower pond to the upper pond for subsequent utilisation for power generation during peak hours. In view of some of the infra structural facilities such as storage ponds, water conductor system, transmission lines, etc. being already available, at the existing hydro power stations owned by TEC, the pumped storage units are being proposed within the environs of existing hydro stations, i.e. a 150 MW pumped storage unit at Bhira and a 90 MW pumped storage unit at Bhivpuri. The projects are ...
1992-01-01
Hydroelectric and pumped storage plants
Energy Technology Data Exchange (ETDEWEB)
All power plant engineers face the problem of peak power demands. Pumped storage plants are used to generate peak load power by pumping up water utilizing off-peak energy of hydrothermal and thermonuclear plants. This is the first accessible text/reference to cover hydroelectric power generation with emphasis on engineering to meet peak power demands by means of pumped storge plants, tidal power plants, and low head power generation. Text covers hydrology, mechanical and electrical equipment, accessories such as penstocks and valves, and civil engineering considerations. Contains descriptions of several existing plants. Includes 200 diagrams and 50 photographs.
1989-01-01
Hydroelectric and pumped storage plants
Energy Technology Data Exchange (ETDEWEB)
All power plant engineers face the problem of peak power demands. Pumped storage plants are used to generate peak load power by pumping up water utilizing off-peak energy of hydrothermal and thermonuclear plants. This is a reference to cover hydroelectric power generation with emphasis on engineering to meet peak power demands by means of pumped storage plants, tidal power plants, and low head power generation. Text covers hydrology, mechanical and electrical equipment, accessories such as penstocks and valves, and civil engineering considerations. Contains descriptions of several existing plants. Includes 200 diagrams and 50 photographs.
1988-01-01
Back-up for high voltage cable pressurizing system
Energy Technology Data Exchange (ETDEWEB)
A back-up system is provided for a pumping plant or a pressure reservoir system used to maintain insulating oil under pressure in high voltage submarine power cables which includes a gas driven membrane pump to insure a small outflow of oil at a rupture point in the power cable to prevent water from penetrating the cable. The proper operation of the membrane pump is insured by introducing degasified oil at the drive side of the pump during the stand-by and test modes of operation of the back-up system. 11 drawings.
1982-07-19
Energy Technology Data Exchange (ETDEWEB)
Analyzing various SBLOCA with high pressure safety injection (HPSI) at VVER-440/213, we met a surprising phenomenon - a 'natural' circulation post SG heat transfer reversal. This is not usual, because normal natural circulation (NC) in primary circuit is connected with positive heat transfer at SG. If there is reverse heat transfer at SG (as soon as the break enthalpy outflow is sufficient for removal of reactor decay heat), it should obstruct any natural circulation. The question was, what is the driving force of this 'non-standard natural circulation'. After all we revealed that force - it is the density difference between the colder water in reactor downcomer (cold water from HPSI) and warmer water in inner reactor (lower plenum, core, upper plenum). This phenomenon could be confusing for operating ...
2001-07-01
International Nuclear Information System (INIS)
Analyzing various SBLOCA with high pressure safety injection (HPSI) at VVER-440/213, we met a surprising phenomenon - a 'natural' circulation post SG heat transfer reversal. This is not usual, because normal natural circulation (NC) in primary circuit is connected with positive heat transfer at SG. If there is reverse heat transfer at SG (as soon as the break enthalpy outflow is sufficient for removal of reactor decay heat), it should obstruct any natural circulation. The question was, what is the driving force of this 'non-standard natural circulation'. After all we revealed that force - it is the density difference between the colder water in reactor downcomer (cold water from HPSI) and warmer water in inner reactor (lower plenum, core, upper plenum). This phenomenon could be confusing for operating personal, because there would be an ...
2001-03-20
Preliminary study of the effect of pumped-storage plant operation on zooplankton
Energy Technology Data Exchange (ETDEWEB)
The hydromechanical effect of hydroelectric stations on zooplankton is customarily regarded as a constantly acting and comparatively harmless factor, since its destruction is inevitable when water masses are passed through hydroelectric stations, but its capacity for restoration is high (i.e., destruction of the zooplankton of the forebay is compensated by its production in the after bay). It is not known how correct such an opinion is, or what is the true balance of losses and reproduction of zooplankton in the forebays and after bays of hydroelectric stations. However, hydroelectric plants of a new type, pumped-storage plants, have been constructed in recent years and others are planned for the Dnieper reservoirs. The operational principle and purpose of these plants is that they employ special vertical turbine-electric pumps that pump water at night from the reservoirs into ...
1980-01-01
Feedwater control device for a reactor
International Nuclear Information System (INIS)
Purpose: To eliminate the water level deviation due to the recycling flowrate, as well as enable a stable control to a reference value even upon changes in the recycling flowrate caused by the variation in the opening degree of a minimum flow valve. Constitution: Reactor recycling system comprises a feedwater pump, a flowrate control valve, a reactor water level detector, and a minimum flow line and a minimum flow valve for preventing the overheating of the feedwater pump at a low flowrate. A flowrate compensator is further disposed, in which a recycling flowrate signal is subtracted from a pump flow rate signal and the result is fedback as a compensated pump flowrate signal. This enables the control system to operate at a rapid response for suppressing the effect of the recycling flowrate as external disturbance, whereby the water level in ...
1981-11-18
Underground Mine Water Heating and Cooling Using Geothermal Heat Pump Systems
Energy Technology Data Exchange (ETDEWEB)
In many regions of the world, flooded mines are a potentially cost-effective option for heating and cooling using geothermal heat pump systems. For example, a single coal seam in Pennsylvania, West Virginia, and Ohio contains 5.1 x 1012 L of water. The growing volume of water discharging from this one coal seam totals 380,000 L/min, which could theoretically heat and cool 20,000 homes. Using the water stored in the mines would conservatively extend this option to an order of magnitude more sites. Based on current energy prices, geothermal heat pump systems using mine water could reduce annual costs for heating by 67% and cooling by 50% over conventional methods (natural gas or heating oil and standard air conditioning).
2006-03-01
Rural residential application of geothermal heat pump. Final grant report
Energy Technology Data Exchange (ETDEWEB)
A project to demonstrate residential heating and cooling with a well-water source heat pump is documented. The system is schematically illustrated and described, and project experience is discussed. The system is capable of using source water as cool as 40/sup 0/F. Project expenses are accounted for. (LEW)
1982-07-30
A cryocondensation pump for the DIII-D Advanced Divertor Program
Energy Technology Data Exchange (ETDEWEB)
A cryocondensation pump was designed for the baffle chamber of General Atomics DIII-D tokamak and will be installed in the fall of 1992. The purpose of the pump is to study plasma density control by pumping the divertor. The pump is toroidally continuous, approximately 10 m long and located in the lower outer corner of the vacuum chamber of the machine. It consists of a 1 m{sup 2} liquid helium-cooled surface surrounded by a liquid nitrogen-cooled shield to limit the heat load on the helium-cooled surface. The liquid nitrogen-cooled surface is surrounded by a radiation/particle shield to prevent energetic particles from impacting and releasing condensed water molecules. A thermal enhancement coating was applied to the nitrogen shell to lower the maximum temperature of the shell. The coating is non-continuous to keep the toroidal electrical resistance high. The whole ...
1992-03-01
An Experimental study on a Method of Computing Minimum flow rate
International Nuclear Information System (INIS)
Many pump reliability problems in the Nuclear Power Plants (NPPs) are being attributed to the operation of the pump at flow rates well below its best efficiency point(BEP). Generally, the manufacturer and the user try to avert such problems by specifying a minimum flow, below which the pump should not be operated. Pump minimum flow usually involves two considerations. The first consideration is normally termed the 'thermal minimum flow', which is that flow required to prevent the fluid inside the pump from reaching saturation conditions. The other consideration is often referred to as 'mechanical minimum flow', which is that flow required to prevent mechanical damage. However, the criteria for specifying such a minimum flow are not clearly understood by all parties concerned. Also various factor and information for computing minimum flow are not easily available as considering for ...
2009-10-01
Benefit analysis and evaluation of pumped-storage plant in Taipower system
Energy Technology Data Exchange (ETDEWEB)
The operation of pumped-storage plants (PSP) is based on the daily load variations of power demand. It performs power generation at peak load times during the day, and pumps water up into the reservoir during the off-peak times at night. In the Taipower system in Taiwan, there are two pumped storage plants with ten units. These had a total installed capacity of 2,602 MW or a 12 percent capacity at the end of 1995. The plants were able to reduce system generation costs and improve reliability. A Pumped-Storage Plant Benefit Analysis (PSPBA) program was established using the principle of economic dispatch in 1985. This paper explains the rules of the program, the analysis results of the past 10 years, and a a cost benefit evaluation. It was found that the advantages of PSP are not only in supplying the power for peak load, but also in decreasing the total fuel cost. 5 figs., 4 refs.
1995-12-31
Improvement of the PGV-1000 steam generator in-vessel components
International Nuclear Information System (INIS)
Results of calculational investigations into circulation of water and steam-and-water mixture in the PGV-1000 steam generator heat exchanger bundle used at NPPs with the WWER-1000 reactors, are considered. Model of water circulation in horizontal steam generator with submerged heating surface under conditions of steam generation irregularity along the heat transfer tubes is made. On the basis of the obtained data the assumption is made about water essential overflows from the hot collector zone into the cold one. Overflow rate over the upper line of the heat transfer tubes may constitute 0.7 m/s. The conclusion is made about the necessity to set up the vertical barrier which divides hot and cold sections of heat transfer tubes and helps to avoid water transverse overflows.
1988-01-01
Lamp system for uniform semiconductor wafer heating
Energy Technology Data Exchange (ETDEWEB)
A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.
2001-01-01
International Nuclear Information System (INIS)
Purpose: To remove excessive driving pressure applied to an unisolated control rod drive by returning excessive coolant to a condensed water storage tank or to the inlet side of a drive water pump using a coolant flow rate control pipe of a control rod driving hydraulic system. Constitution: Excessive water is returned to a condensed water tank while controlling the excessive coolant by a flow control valve in response to variations in the pressure difference between the reactor pressure and the driving water line when the control rods are isolated using a pipe from the outlet side of the drive water pump to the condensed water storage tank. Thus, the control rod to be isolated is prevented form being dropped. (Sekiya, K.).
Energy Technology Data Exchange (ETDEWEB)
The merits of single stage absorption heat pumps coupled to simple distillation for effluent treatment are discussed. An experimental integrated absorption heat pump effluent purification system (IAHPEPS) was built and operated with water-lithium bromide as a working mixture. This unit has been used to raise the temperature and hence, the vapour pressure of the impure water contained in one vessel, to the point where pure water vapour will distil from impure effluent solution (tap water or brine) and condense in a second vessel used to collect pure water. Pure effluent production rates of between 0.5 and 4.3 kg h{sup -1} were obtained. The actual coefficient of performance (COP{sub A}) and the heat pump effectiveness varied from 1.1 to 1.4 and 0.58 to 0.72, respectively. The results from the small scale systems indicate ...
1999-05-01
Energy Technology Data Exchange (ETDEWEB)
An inorganic particulate adsorbent of a titania-alumina is described for treating a superheated water containing radioactive materials such as cobalt ions, which is free from release of corrosive impruities, and which has a high adsorption capacity of radioactive materials and a high mechanical strength is prepared by hydrolyzing a titanium alkoxide and an aluminum alkoxide, thereby forming a hydrous titanium oxide and a hydrous aluminum oxide, respectively; precalcining the hydrous titanium oxide and aluminum oxide, mixing and molding the resulting titania and alumina into a particulate mixture thereof having a titania mole fraction of 0.2 to 0.9, and calcining the particulate mixture at 500/sup 0/-700/sup 0/C. This absorbent is effectively used in treat boiling water-type nuclear reactor core-circulating water to remove radioactive substances therefrom.
1981-08-04
Energy Technology Data Exchange (ETDEWEB)
This analysis defines and evaluates the surface water supply system from the existing J-13 well to the North Portal. This system includes the pipe running from J-13 to a proposed Booster Pump Station at the intersection of H Road and the North Portal access road. Contained herein is an analysis of the proposed Booster Pump Station with a brief description of the system that could be installed to the South Portal and the optional shaft. The tanks that supply the water to the North Portal are sized, and the supply system to the North Portal facilities and up to Topopah Spring North Ramp is defined.
1996-02-06
Energy Technology Data Exchange (ETDEWEB)
This report documents results of a preliminary hazard analysis (PHA) covering the existing Crane Chempump and the new salt well pumping design. Three hazardous conditions were identified for the Chempump and ten hazardous conditions were identified for the new salt well pump design. This report also presents the results of the control decision/allocation process. A backflow preventer and associated limiting condition for operation were assigned to one hazardous condition with the new design.
2000-11-16
Freeze protection valve and system
Energy Technology Data Exchange (ETDEWEB)
The present invention is a device for a solar heating system having a solar collector, a storage tank connected to the solar collector, a pump for circulating liquid from the tank to the solar collector, a supply of liquid at a temperature above freezing and a connection from the supply of liquid to the solar collector for replacing any liquid lost from said solar collector. The device comprises a sensor for sensing the temperature of liquid in the solar collector, and a valve for bleeding liquid from the solar collector when the sensed temperature falls below a predetermined minimum whereby cool liquid in the solar collector is automatically replaced by liquid at a temperature above freezing.
1985-12-10
International Nuclear Information System (INIS)
In summary, a scaling analysis of a water-cooled Reactor Cavity Cooling System (RCCS) system was performed based on generic information on the RCCS design of PBMR. The analysis demonstrates that the water-cooled RCCS can be simulated at the ANL NSTF facility at a prototypic scale in the lateral direction and about half scale in the vertical direction. Because, by necessity, the scaling is based on a number of approximations, and because no analytical information is available on the performance of a reference water-cooled RCCS, the scaling analysis presented here needs to be 'validated' by analysis of the steady state and transient performance of a reference water-cooled RCCS design. The analysis of the RCCS performance by CFD and system codes presents a number of challenges including: strong 3-D effects in the cavity and the RCCS tubes; simulation of turbulence in flows characterized by natural ...
Phytoplankton primary production in a eutrophic cooling water pond
Energy Technology Data Exchange (ETDEWEB)
The effect of longer ice-free periods on the seasonal variation and total annual values of phytoplankton primary production was considered along with the efficiency and productivity of the phytoplankton communities at different water temperatures by constant light. The studied pond, Vasikkalampi, is located in the town Jvyaskyla in central Finland. The pond is slightly eutrophic and its water is used for cooling purposes by a 35 MW thermal powerplant. The cooling water is taken in the middle of the pond and it returns as heated effluent to the northern part, near the surface, about 100 m from the intake pipe. This circulation and warming of the water keeps the pond open throughout the year except during the coldest weeks in the winter when some parts freeze over. The increase of the water temperature was not sufficient to be optimal for photosynthesis in the ...
1984-01-01
Hybrid solution and pump-storage optimization in water supply system efficiency: A case study
International Nuclear Information System (INIS)
Environmental targets and saving energy have become ones of the world main concerns over the last years and it will increase and become more important in a near future. The world population growth rate is the major factor contributing for the increase in global pollution and energy and water consumption. In 2005, the world population was approximately 6.5 billion and this number is expected to reach 9 billion by 2050 [United Nations, 2008. (www.un.org), accessed on July]. Water supply systems use energy for pumping water, so new strategies must be developed and implemented in order to reduce this consumption. In addition, if there is excess of hydraulic energy in a water system, some type of water power generation can be implemented. This paper presents an optimization model that determines the best hourly operation for 1 day, according to the electricity ...
2008-11-01
Natural circulation decay heat removal experiments and analysis in an LMFBR fuel assembly
International Nuclear Information System (INIS)
Water flow experiments were conducted on natural circulation decay heat removal with an electrically heated 91-rod bundle. Experimental results were compared with analytical predictions to provide thermal hydraulic characteristics for LMFBR Fuel assemblies under a low flow, typical of the natural circulation regime. The results revealed that, at low flow rate region (Re<1,200), axial friction loss in a heated bundle increases with buoyancy effect. The radial temperature profile provides some insight regarding the concept that coolant redistribution would occur. COBRA-V-I predictions are successfully proved validity in comparison with experimental results.
1982-07-01
Modelling of two-phase natural circulation in a WWER-plant: PMK experimental results
International Nuclear Information System (INIS)
Experiments have been performed with the PMK integral-type facility, a model of WWER-440 type PWRs, to investigate two-phase natural circulation behaviour. The phenomena to be expected in this reactor type are different from those in PWRs with vertical steam generators mainly due to the loop seal in the hot leg and the horizontal layout of the steam generator heat transfer tubes. The experiments showed that the system is repressurized when the water level drops to the hot leg elevation due to the effect of the loop seal. Opening of the loop seal can be smooth, but may lead to oscillations depending on the power and the mass inventory. Natural circulation recovers after the hot leg loop seal is opened, but then decreases with further mass inventory decrease. (orig.).
Reliability assessment of hydrothermal generation systems containing pumped storage plant
Energy Technology Data Exchange (ETDEWEB)
Previous models and evaluation techniques based on the Monte Carlo simulation for the reliability assessment of mixed hydrothermal generation systems are extended. Models for reservoirs on multiple rivers and pumped storage plants are developed. Operating and water management policies are extended to include the relative economical effects of operating alternative sources of generation. These effects and the benefits are described and discussed using an extended IEEE reliability test system. (Author).
1991-11-01
Inherent Boron Dilution Safety Issue in the French Pressurized Water Reactor: CFD Approach
International Nuclear Information System (INIS)
Inherent boron dilution can occur in case of a Small Break LOCA when low borated water is mainly accumulated in the U-legs due to reflux boiling in the Steam Generator tubes after the loss of natural circulation. The restart of the natural circulation may lead to criticality because of the injection of these low borated slugs towards the core. To evaluate this potential risk, the boron concentration at the core inlet has to be known which makes necessary to estimate the mixing phenomena in the cold leg, in the downcomer and in the lower plenum: CFD calculations are required. First of all the validation of CFX5 CFD code on the relevant phenomena of inherent boron dilution has been established (UPTF TRAM C3 test). Then, an application to the 900 MW French Pressurized Water Reactor series has been performed. (authors)
2006-07-17
Energy Technology Data Exchange (ETDEWEB)
Modern tubular type pumps commonly have lubricated radial bearings which require no compressed water supply and reduce the servicing requirements. Problems that may possibly result from entrained sand in the pumped fluid were solved with the development of ceramic Residur {sup trademark} bearngs in the early eighties. (orig.) [German] In zunehmendem Masse werden Rohrgehaeusepumpen mit foerdermediumgeschmierten Radiallagern ausgestattet, da dies z.B. neben dem Wegfall einer ansonsten notwendigen Druckwasserversorgung auch einen deutlichen reduzierten Wartungsaufwand nach sich zieht. Den Problemen durch eine moegliche Sandbeladung des Foerdermedium wurde bereits durch die Entwicklung der keramischen Residur {sup trademark} -Lager Anfang der 80er Jahre Rechnung getragen. (orig.)
1998-07-01
Energy Technology Data Exchange (ETDEWEB)
This research report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that examined the feasibility of setting up 'MINERGIE' low-energy-consumption module standards for the production of heat in small residential buildings. The aims of the standards and the basic idea behind the MINERGIE-modules are discussed. The concepts of the modules for heat pumps and wood-fired heating systems and their combination with solar installations are examined, as are their areas of application. The requirements placed on the modules are listed. System concepts, including simple schematics for typical installations, are presented for wood-log, wood-chippings and pellets-fired systems as well as for ground-loop and air-water heat pump systems as well as their solar-aided counterparts. The results of cost-benefit analyses are presented and questions regarding system guarantee and liability are ...
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
This patent describes a preflush fluid for preventing lost circulation during the cementing of a well, the fluid consisting essentially of: (a) water; (b) about 10 to about 30 percent by weight of water (% BWOW) cement; (c) about 5 to about 30% BWOW calcium sulfate selected from the group consisting of calcium sulfate hemihydrate, calcium sulfate dihydrate, and mixtures thereof; and (d) an alkali metal-containing quick-hardening accelerator.
1992-01-21
Energy Technology Data Exchange (ETDEWEB)
''Climates of the Oceans'' deals with the atmosphere over the world oceans and provides a treatment not only of the climatic elements such as temperature, pressure, wind, precipitation etc., but also of the circulation of the atmosphere and its changes throughout the year. The connection between sea and overlying air is examined through studies of the water and heat balance. Numerous maps and tables illustrate the elements and their fluctuations over the water and on islands and coasts.
1984-01-01
Cooling facility for reactor container
International Nuclear Information System (INIS)
Cooling water is sprayed on the outer surface of an upper portion of a container, and a pool is formed by the cooling water flowing down while cooling the container. Further, the cooling water stored in the cooling water pool is recycled by a pump for spraying the cooling water on the outer surface of the upper portion of the container. Sufficient amount of cooling water is supplied for spraying the cooling water to the outer surface of the upper portion of the container so that the outer surface of the container is free from drying and a liquid membrane is formed on the entire surface. The amount of the cooling water is made greater than that of the cooling water evaporated when the entire amount of the heat generate in the reactor core of the reactor is transferred to the ...
1993-05-07
International Space Station Overview - NASA
(accumulates & stores brine for disposal). Separator. (separates water from purge gases). ? Purge pump periodically vent ... Reactor Health. Sensor. ( verifies reactor is operating w/n limits) ... Waste and Hygiene Compartment ...
...Filter gaskets and seatings; (4) Pumps; (5) Solvent tanks and containers; (6) Water separators; (7) Muck cookers; (8) Stills; (9) Exhaust dampers; (10) Diverter valves; and (11) All Filter housings. (l)...
2009-07-01
...limited to, emission control devices, pumps, filters, muck cookers, stills, solvent tanks, solvent containers, water separators...facility that meets the conditions of § 63.320(g). Muck cooker means a device for heating perchloroethylene-laden...
2009-07-01
Energy Technology Data Exchange (ETDEWEB)
The paper is concerned with the economic operation of power systems comprising pumped storage and thermal plants. In power systems, pumped storage plants may receive the energy required for pumping water either from the system in which they are integrated or from a neighbouring system. Therefore, two mathematical formulations of the problem are presented depending on the source of energy during pumping. In both cases, the problem is reduced to a non linear optimization problem. Two numerical techniques are suggested for the solution of this optimization problem, namely the Lagrangian Multipliers technique and the Rosen Gradient Projection technique. Numerical examples are presented to demonstrate the techniques. Although the Lagrangian Multipliers technique has the advantage of being a well known technique, however, computer wise, the Rosen Gradient Projection technique proves to be ...
1980-12-01
British Library Electronic Table of Contents (United Kingdom)
Water?rock interaction is one of the prime factors affecting the fluoride contents of surface and groundwater. If fluoride concentration of drinking water has been neglected, excess fluoride can cause serious dental and medical problems on human health, which is well known at Golcuk-Isparta region. In the research area, Egirdir lake, Golcuk lake and surrounding springs have been utilized as drinking water sources. Golcuk lake water and surrounding groundwaters have high fluoride content (1.4?4.6?mg/l), which is above the WHO standards. Fluoride is predominantly supplied by dissolution of fluoride within the fluormicas of volcanics during the circulation of water. Fluoride concentrations of waters have shown variations for dry and rainy seasons depending on the degree of interaction between...
2008-01-01
The formation of todorokite and birnessite in sea water pumped from under ground
Manganese oxides precipitated from aerated well sea water at the Marine Science Museum, Tokai University, have been analyzed chemically and mineralogically. The O / Mn ratios are lower in todorokite than in birnessite but these minerals have similar contents of minor transition metals, which can be taken up additionally from sea water after the precipitation of Mn oxides. On the basis of these results, the genesis of Mn minerals is discussed in relation to marine Mn nodules.
1984-05-01
Technical-economic aspects of the utilization of geothermal waters
International Nuclear Information System (INIS)
A brief description is given of the physico-chemical parameters characterized a hot water geothermal reservoir and of its exploitation by means of single or coupled (doublet) wells. The technical aspects of geothermal heat to the users is then discussed, beginning with corrosion of materials caused by seven main agents: oxygen, hydrogen sulphide, carbon dioxide, ammonia, hydrogen, sulphates and chlorides. A brief mention is made of scaling due to calcium carbonate, silica and calcium sulphates. The basic components of a geothermal plant for non-electric uses are then discussed: production pumps, surface pipelines, heat exchangers, heat pumps and reinjection pumps. The advantages and disadvantages of the different equipment and materials used in the geothermal sector are also presented. A list is also given of the criteria used in the energy and economic balance of a geothermal operation. (author). 24 ...
International Nuclear Information System (INIS)
At a military base in the Southeastern US, an energy services company (ESCO) has proposed to retrofit more than 1,000 family residences with geothermal heat pumps as part of an energy savings performance contract (ESPC). Each residence is to have one heat pump with its own ground heat exchanger consisting of two or more vertical bores. A design firm hired by the ESCO sized the heat pumps to meet peak cooling loads, and sized the borefields to limit the maximum entering water temperature (EWT) to the heat pumps to 95 F (35 C). Because there is some disagreement in the geothermal heat pump industry over the peak temperature to be used for design (some designers and design manuals recommend temperatures as low as 85 F[29 C], while equipment manufacturers and others specify temperatures of 100 F[38 C] or higher) the authors were requested to examine the designs in ...
Energy Technology Data Exchange (ETDEWEB)
Ground-water monitoring near the Raft River site was initiated in 1974 by the IDWR. This effort consisted of semiannual chemical sampling of 22 irrigation wells near the Raft River geothermal development area. This program yielded useful baseline chemical data; however, several problems were inherent. For example, access to water pumped from the wells is limited to the irrigation season (April through September). All the wells are not continuously pumped; thus, some wells that are sampled one season cannot be sampled the next. In addition, information on well construction, completion, and production is often unreliable or not available. These data are to be supplemented by establishing a series of monitor wells in the proposed geothermal withdrawal and injection area. These wells were to be located and designed to provide data necessary for evaluating and predicting the impact of geothermal development ...
1982-09-01
CFX code application to the French reactor for inherent boron dilution safety issue
International Nuclear Information System (INIS)
Inherent boron dilution can occur in case of a small Break LOCA when low borated water is accumulated in the U-legs due to reflux boiling in the Steam Generator tubes after the loss of natural circulation. The restart of the natural circulation may lead to criticality because of the injection of these low borated slugs towards the core. To evaluate this potential risk, the boron concentration at the core inlet has to be known which makes necessary to estimate the mixing phenomena in the cold leg, in the downcomer and in the lower plenum: CFD calculations are required. First of all the validation of CFX5 CFD code on the relevant phenomena of inherent boron dilution has been established (UPTF TRAM C3 test). Then, an application to the 900 MW French Pressurized Water Reactor series has been performed. (authors)
2006-09-05
Energy Technology Data Exchange (ETDEWEB)
The very low-pressure expansion tank of the title invention is connected to the water in the central heating installation via a connecting pipe with a pump and valves on one side, and on the other side the tank is connected via a connecting pipe with valve to the tap water mains, so that the supply of water can be regulated automatically. Within the expansion tank contact with the outside air is not possible because of an air/water separating floater. By means of recording and control (also remote) of the contents of the expansion tank, the installation pressure and the quantity of supplied water from the expansion tank and the tap water mains, failures and water damage are prevented. 4 figs.
1995-09-01
The importance of sodium plume behaviour in the natural convection cooling of fast reactors
International Nuclear Information System (INIS)
This paper relates to a simple approach to the analysis of the behaviour of pool type LMFBR primary circuits in natural convection and to experimental work to support this approach. The primary application is the prediction of plant behaviour in decay heat removal conditions when depending on natural convection effects to cool the core. In formulating a mathematical model of the plant for this application, the main difficulty is the modelling of the large plena between the core and IHX and the IHX and the pump inlet. In a previous paper discussing CDFR behaviour after a reactor scram with total loss of power to the primary pumps, the first author described attempts to model the CDFR hot pool in a way which would be limiting in a pessimistic sense. The shortcomings of these attempts were reviewed and mention was made of an improved method then under development. Essentially, the improved model allowed for migration of hot sodium from the core to ...
Energy Technology Data Exchange (ETDEWEB)
The main objective of the present study is twofold: (i) to analyze thermal loads of the geothermally and passively heated solar greenhouses; and (ii) to investigate wind energy utilization in greenhouse heating which is modeled as a hybrid solar assisted geothermal heat pump and a small wind turbine system which is separately installed in the Solar Energy Institute of Ege University, Izmir, Turkey. The study shows 3.13% of the total yearly electricity energy consumption of the modeled system (3568 kWh) or 12.53% of the total yearly electricity energy consumptions of secondary water pumping, brine pumping, and fan coil (892 kWh) can be met by using small wind turbine system (SWTS) theoretically. According to this result, modeled passive solar pre heating technique and combined with geothermal heat pump system (GHPS) and SWTS can be economically preferable to the conventional space ...
2010-01-15
Influence of two systematic parameters on the geothermal heat pump system operation
Energy Technology Data Exchange (ETDEWEB)
In order to match the output capacity of a geothermal heat pump system (GHPS) with the actual load requirement, research has been carried out in finding the influence of two systematic parameters, the water flow rate inside the condenser and the compressor input frequency on the GHPS operation. Experiments are done on a small-scale GHPS at the water flow rate ranging from 0.054 kg/s to 0.174 kg/s and the frequency from 30 Hz to 55 Hz. The analysis of the experimental data reveals the relationships among the compressor frequency, the water flow rate and other important parameters such as coefficient of performance (COP), heat capacity and compressor power input. The conclusions in the paper can serve as some guidance to the load adjustment of GHPS. (author)
2003-01-01
Origin of water salinity in the coastal Sarafand aquifer (South-Lebanon)
International Nuclear Information System (INIS)
Author.The geochemical and isotopic study, based on the analysis of twenty water samples from well in the coastal plain of Sarafand (South-Lebanon), permit to eliminate the hypothesis of marine intrusion in this aquifer. The increase of salinity observed in certain wells is due to the contamination of cretaceous aquifer water by the quaternary formations. The two poles of mixing are respectively characterized: by weak tritium contents (between 2 and 3 UT) and a value of stable isotopes (-5,9<0,18<-5,5) corresponding to the appearance of cretaceous formation area; by the high tritium contents and enrichment relative to heavy isotope in the mineralized water of superficial formations. On the other hand, the isotope contents permit the set a rapid renewal of the cretaceous aquifer water due to quick circulation in the Karstic system
The Philadelphia Marriott: A convention center flagship hotel
Energy Technology Data Exchange (ETDEWEB)
This article describes the state-of-the-art HVAC system at the Philadelphia Marriott Hotel. Thermal comfort and indoor air quality are emphasized. The system uses a hybrid gas absorption/electric centrifugal chilled water plant, variable flow pumping, water-side economizers to provide free cooling, central air handling units with air-side economizers and flow monitoring equipment.
1997-01-01
International water power and dam construction yearbook 1996
Energy Technology Data Exchange (ETDEWEB)
This document draws together data on hydroelectric power generation and dam construction for 1996. Machinery such as turbines and hydroelectric generators are listed together with their manufacturers. Contact addresses for international organizations concerned with water power are listed. Listings are also given for hydro resources worldwide, and the global distribution of pumped-storage plants, dams and hydroelectric plants. Company data is also listed providing a buyer`s guide for 1996. (UK)
1996-12-31
A method for isolating a water influx into a well
Energy Technology Data Exchange (ETDEWEB)
The goal of the invention is to increase the effectiveness of the isolation process through increasing the waterproofing of the stratum. The cited goal is achieved by isolating water influx into a well through introduction of a chemical reagent into the stratum. To interact with the stratum, an alloy of titanium and iron is introduced into the stratum as the chemical reagent with subsequent pumping of hydrogen into the stratum at 100 to 200C.
1983-01-01
Coupling of geothermal heat pumps with thermal solar collectors
Energy Technology Data Exchange (ETDEWEB)
The study discussed relates to the design and development of a process consisting of combining a reversible geothermal heat pump with thermal solar collectors for building heating and cooling and the production of domestic hot water. The proposed process, called GEOSOL, has been installed in a 180 m{sup 2} private residence in 2004. This installation is the subject of long-term experimental follow-up to analyse the energy-related behavior of the installation at all times of the year. In addition, different configurations of this combined system (geothermal heat pump and thermal solar collectors) have been defined and will be simulated numerically using TRNSYS software. A comparative analysis of these different alternative versions will be conducted to determine the best configuration(s) of the GEOSOL process in terms of energy, economical and environmental performances. (author)
2007-07-15
British Library Electronic Table of Contents (United Kingdom)
Aim: To evaluate the usefulness of routine laboratory parameters in the decision to treat refractory cardiac arrest patients with extracorporeal life support (ECLS). Methods: Sixty-six adults with witnessed cardiac arrest of cardiac origin unrelated to poisoning or hypothermia undergoing cardiopulmonary resuscitation without return of spontaneous circulation (duration: 155min [120-180], median, [25-75%-percentiles]) were included in a prospective cohort-study. ECLS was implemented under cardiac massage, using a centrifugal pump connected to a hollow-fiber membrane-oxygenator, aiming to maintain ECLS flow >=2.5l/min and mean arterial pressure >=60mmHg. Results: Forty-seven of 66 patients died within 24h from multiorgan failure and massive capillary leak. Of 19/66 patients who survived >=24h...
2011-01-01
Fundamental aspects of gas-liquid flows
Energy Technology Data Exchange (ETDEWEB)
This book presents the papers given at a conference on two-phase flow. Topics considered at the conference included the thermal hydraulics of a feedwater pipe breakage, pressure losses, measurement of void fraction in a rod bundle, laminar filmwise condensation, natural circulation, flow models, bubble dynamics, cavitation, water hammer, and heat transfer augmentation.
1985-01-01
Fundamental aspects of gas-liquid flows
International Nuclear Information System (INIS)
This book presents the papers given at a conference on two-phase flow. Topics considered at the conference included the thermal hydraulics of a feedwater pipe breakage, pressure losses, measurement of void fraction in a rod bundle, laminar filmwise condensation, natural circulation, flow models, bubble dynamics, cavitation, water hammer, and heat transfer augmentation.
1985-11-17
Low temperature humidification dehumidification desalination process
Energy Technology Data Exchange (ETDEWEB)
The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling ...
2006-03-01
Low temperature humidification dehumidification desalination process
International Nuclear Information System (INIS)
The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling ...
2006-03-01
Energy Technology Data Exchange (ETDEWEB)
Before the implementation Water Framework directive, it was usual to forget that a good environment protection of the receiving waters needs a correct and coordinated operation of the subsystems of the water cycle, specially sewerage system, WWTP and receiving waters. This explains that most of the countries have focused their efforts in the treatment of dry weather flows forgetting the management of wet weather flows. Actually the idea that a sewerage system or a WWTP can not be planned or managed independently without considering the effects on the receiving waters is commonly accepted because not only each one of these systems must work correctly but also it is required a minimum impact in the receiving waters of the sewerage and WWTP overflows in dry and wet weather. All these links will affect the management strategy of the sewerage system (storm ...
2005-07-01
Uptake and translocation of {sup 137}Cs by Houttuynia cordata (in water culture)
Energy Technology Data Exchange (ETDEWEB)
The water culture experiment of Houttuynia cordata of the medicinal plant was carried out, and basic study on {sup 137}Cs accumulation characteristic and internal circulation in H. cordata in the fruiting stage was investigated since the flowering season. H. cordata accumulated 80% of {sup 137}Cs absorbed unlike K to the root, rhizome, terminal bud of the underground part for the rhizome reproduction. {sup 137}Cs content to the young leaf, spike, involucre increased in the flowering season. Thereafter, {sup 137}Cs was recirculated to the developing organs in second generations such as the rhizome and bud. (author)
2001-08-01
Energy Technology Data Exchange (ETDEWEB)
Since 1976, the Nuclear Engineering Laboratory of the Technical Research Centre of Finland and Lappeenranta University of Technology have cooperated in the field of nuclear reactor thermal-hydraulics. During these years, a series of experimental facilities (REWET-I, -II, -III, VEERA) simulating pressurized water reactors (PWRs) have been built. The newest facility, PACTEL (Parallel Channel Test Loop), is an experimental out-of-pile facility designed to simulate the major components and system behaviour of a commercial PWR during postulated small and medium size break loss-of-coolant accidents (LOCAs), natural circulation and operational transients. A PACTEL natural circulation experiment has been carried out as an OECD/NEA international standard problem ISP 33. (2 refs., 3 figs., 2 tabs.).
1993-12-31
Energy Technology Data Exchange (ETDEWEB)
Petropavlovsk-Kamchatky (P-K) city in Kamchatka, Russia is operating hot-water district heating using heavy oil boilers and waste hot water of thermal power plants as heat sources. Feasibility study was made on district heating using natural geothermal hot water and/or geothermal heat pump systems as heat sources of hot water supply for reduction of greenhouse effect gas emission. Among 3 areas including geothermal hot water, use of hot water in K area was impossible because of lower temperature and less spring water. Use of hot water in P and UP areas was impossible as primary hot water because of temperature drop to 64 degrees C during hot water supply toward P-K city. The building heating operation test was carried out using the geothermal heat ...
1999-05-01
British Library Electronic Table of Contents (United Kingdom)
The effect of phosphonate anion (PHOS) on the corrosion of ordinary steel in simulated cooling water has been studied using weight loss, polarization curves and electrochemical impedance spectroscopy measurements. PHOS was studied in the concentration range from 7.5x10^-^5 to 10^-^3M. The results obtained reveal that PHOS perform excellently as corrosion inhibitor for ordinary steel in simulated cooling water. The inhibition efficiency of PHOS was increased with increasing both its concentration and water circulation velocity. These two factors seem to promote the adsorption of phosphorus and oxygen ions on the metal surface, leading to the formation of a protective layer with a greater charge transfer resistance and lower permeability. The inhibition efficiency decreased slightly with tem...
2010-01-01
A calculation model for thermo-hydraulic analyses of the PGV-1000 steam generator
International Nuclear Information System (INIS)
A calculation model was developed for the analysis of thermal and hydraulic processes in the PGV-1000 horizontal steam generator. The model makes it possible to examine the hydraulics of the primary medium, i.e., the distribution of flow velocities and mass flows in the exchanger tube system and hydraulic losses of the primary medium in the steam generator during its flow between the two connecting sites to the main circulation pipeline, spatial distribution of heat fluxes between the primary and secondary sides of the steam generator and the total transmitted thermal power, pressure on the secondary side of the generator, natural circulation of the working medium on the secondary side, and the mean circulation number, spatial distribution of the volume fraction of the steam component in the intertubular space, effect of the perforated sheet on the thermo-hydraulic processes in the steam generator, redistribution of the ...
1994-01-01
Energy Technology Data Exchange (ETDEWEB)
The river Saale cascade consists of seven reservoirs with a total capacity of approx. 415 Mio. m[sup 3]. The entire reservoir system covers a catchment area of 1665 km[sup 2]. The water management tasks extend to the following main fields: flood protection upkeep of minimum water stock, salt load control and power generation. The energy supply capacity of the cascade is mainly used by pumped storage plants. The last of these plants, Hohenwarte II, was put into service in 1963. (orig.)
1993-01-01
High concentration low wattage solar arrays and their applications
Energy Technology Data Exchange (ETDEWEB)
Midway Labs currently produces a 335x concentrator module that has reached as high as 19{percent} active area efficiency in production. The current production module uses the single crystal silicon back contact SunPower cell. The National Renewable Energy Lab has developed a multi junction cell using GalnP/GaAs technologies. The high efficiency ({gt}30{percent}) and high cell voltage offer an opportunity for Midway Labs to develop a tracking concentrator module that will provide 24 volts in the 140 to 160 watt range. This voltage and wattage range is applicable to a range of small scale water pumping applications that make up the bulk of water pumping solar panel sales. {copyright} {ital 1997 American Institute of Physics.}
1997-02-01
Intestinal circulation during inhalation anesthesia
Energy Technology Data Exchange (ETDEWEB)
This study was designed to evaluate the influence of inhalational agents on the intestinal circulation in an isolated loop preparation. Sixty dogs were studied, using three intestinal segments from each dog. Selected intestinal segments were pumped with aortic blood at a constant pressure of 100 mmHg. A mixture of /sub 86/Rb and 9-microns spheres labeled with /sup 141/Ce was injected into the arterial cannula supplying the intestinal loop, while mesenteric venous blood was collected for activity counting. A very strong and significant correlation was found between rubidium clearance and microsphere entrapment (r = 0.97, P less than 0.0001). Nitrous oxide anesthesia was accompanied by a higher vascular resistance (VR), lower flow (F), rubidium clearance (Cl-Rb), and microspheres entrapment (Cl-Sph) than pentobarbital anesthesia, indicating that the vascular bed in the intestinal segment was constricted and flow (total and nutritive) decreased. ...
1985-04-01
Intestinal circulation during inhalation anesthesia
International Nuclear Information System (INIS)
This study was designed to evaluate the influence of inhalational agents on the intestinal circulation in an isolated loop preparation. Sixty dogs were studied, using three intestinal segments from each dog. Selected intestinal segments were pumped with aortic blood at a constant pressure of 100 mmHg. A mixture of _8_6Rb and 9-microns spheres labeled with "1"4"1Ce was injected into the arterial cannula supplying the intestinal loop, while mesenteric venous blood was collected for activity counting. A very strong and significant correlation was found between rubidium clearance and microsphere entrapment (r = 0.97, P less than 0.0001). Nitrous oxide anesthesia was accompanied by a higher vascular resistance (VR), lower flow (F), rubidium clearance (Cl-Rb), and microspheres entrapment (Cl-Sph) than pentobarbital anesthesia, indicating that the vascular bed in the intestinal segment was constricted and flow (total and nutritive) decreased. ...
The use of isotopes in hydrology: Proceedings of a symposium, held in Beirut -Lebanon, December 1970
International Nuclear Information System (INIS)
The papers presented at the symposium had covered three general areas in which isotopes could have been beneficially used. these areas are: -Water use and water use efficiency studies. -Ground water investigations -Water problems in the arab countries. The individual papers had dealt with these subjects: -Hydrological research in the arab countries by use of radioisotopes. -The perspectives of use of radioisotopes in hydrological studies in Syria. -Water use efficiency and sub-soil water studies. -Sea water inclusion in a coast el aquifers in Lebanon. -Irrigation requirements of crops in Lebanon as determined by a Neutron probe with reference to other methods. -The use of the neutron moisture meter and other methods of the determination of the evapotranspiration of maize. -Ground water investigations, dating and nuclear ...
1970-12-01
Overview of Cooling Water System for the KSTAR 1st Plasma Experiment
International Nuclear Information System (INIS)
The KSTAR cooling water system (CWS) consists of a primary cooling water system (PCWS), a secondary cooling water system (SCWS), and a de-mineralizing and de-ionized water system (DIWS). The PCWS cooling loops have been made for the poloidal field (PF) and toroidal field (TF) magnet power supplies (MPS), vacuum vessel (VV), electron cyclotron heating (ECH), ion cyclotron heating (ICRH), vacuum pumps, diagnostics, helium facility, etc. The CWS had been done individual commissioning of each system to confirm the design specifications by the end of 2006 and had gradually begun operation for the KSTAR ancillary devices by March 2008
2009-05-01
Variable-speed generation enhances hydro operation
Energy Technology Data Exchange (ETDEWEB)
Two major developments have given impetus to wider adoption of variable-speed turbine/generators in hydroelectric plants, both essentially environmental: (1) the need for stream-bed stability below river dams, and (2) the need to minimize fish damage. Also, the need to stabilize pumped-storage and generating efficiencies to match extreme changes in head levels has been a driving force. Variable-speed operation in hydro applications is relatively new to North America. In other parts of the world, it has been used in pumped-storage plants since 1971. In the US, and increasing potential exists for variable-speed hydro, considering the 30 pumped-storage plants already in operation and several river plants struggling with high head fluctuations--including four at stations operated by the Bonneville Power Administration. Several modifications to hydro-plant hardware and operating procedures are actively being considered at ...
1993-07-01
Water consumption during solid state sodium borohydride hydrolysis
Energy Technology Data Exchange (ETDEWEB)
In this paper nickel acetate catalyzed sodium borohydride cartridges have been prepared and hydrolyzed with water for hydrogen production. Two technological solutions have been tested to increase the overall hydrogen yield, namely a porous water diffuser and a hydrophobic membrane. The first was used to improve water diffusion inside the hydride while the second to confine water inside the cartridge. The generated hydrogen flow showed a very reproducible behavior. Hydrogen promptly evolved just after water was pumped into the cartridge. After some initial peaks, a constant hydrogen flow has been recorded for the whole reaction time. The constant flow was related to the presence of the porous diffuser. The use of a hydrophobic membrane to confine the water inside the cartridge allowed to increase the overall hydrogen yield: about 6 ...
2010-11-15
Radisson community heating systems: technical and economic comparison of options. Final report
Energy Technology Data Exchange (ETDEWEB)
The study reported was conducted to evaluate water source community heat pump systems for possible installation to serve a number of homes which are to be constructed in the northeast section of Radisson, New York. Although specific sites and facilities have been evaluated, it is the intent of this study to be site specific only to the extent of climatic conditions. In other words, the results of this study should apply to any area with similar climate.
1981-12-01
Guide to UK renewable energy companies 2001. 6. ed.
International Nuclear Information System (INIS)
This 2001 edition of the guide to UK renewable companies and equipment and service providers presents summaries of the different industry sectors covering wind power, photovoltaics, solar water heating, geothermal heat pump, hydroelectric power, marine current and wave technology, bioenergy, power generation from landfill gas, energy from waste, and cogeneration. A UK company classification listing and index is provided along with listing of UK organisations and companies and an index of advertisers.
Combined-cycle cogen plant a successful good neighbor
Energy Technology Data Exchange (ETDEWEB)
This article describes a new natural-gas-fired combined cycle cogeneration plant in Bellingham, Washington. The topics of the article include community impact, siting constraints, natural gas fuel, the flexibility provided by the steam turbine, the cooling tower and pumps, air-quality, noise, and cooling water system constraints, and community relations program.
1993-04-01
Simulation experiments for hot-leg U-bend two-phase flow phenomena
International Nuclear Information System (INIS)
In order to study the two-phase natural circulation and flow termination during a small break loss of coolant accident in LWR, simulation experiments have been performed. Based on the two-phase flow scaling criteria developed under this program, an adiabatic hot leg U-bend simulation loop using nitrogen gas and water and a Freon 113 boiling and condensation loop were built. The nitrogen-water system has been used to isolate key hydrodynamic phenomena from heat transfer problems, whereas the Freon loop has been used to study the effect of phase changes and fluid properties. Various tests were carried out to establish the basic mechanism of the flow termination and reestablishment as well as to obtain essential information on scale effects of parameters such as the loop frictional resistance, thermal center, U-bend curvature and inlet geometry. In addition to the above experimental study, a preliminary modeling study has been ...
1986-10-27
Simulation experiments for hot-leg U-bend two-phase flow phenomena
Energy Technology Data Exchange (ETDEWEB)
In order to study the two-phase natural circulation and flow termination during a small break loss of coolant accident in LWR, simulation experiments have been performed. Based on the two-phase flow scaling criteria developed under this program, an adiabatic hot leg U-bend simulation loop using nitrogen gas and water and a Freon 113 boiling and condensation loop were built. The nitrogen-water system has been used to isolate key hydrodynamic phenomena from heat transfer problems, whereas the Freon loop has been used to study the effect of phase changes and fluid properties. Various tests were carried out to establish the basic mechanism of the flow termination and reestablishment as well as to obtain essential information on scale effects of parameters such as the loop frictional resistance, thermal center, U-bend curvature and inlet geometry. In addition to the above experimental study, a preliminary modeling study has been ...
1986-01-01
Results of two-phase natural circulation in hot-leg U-bend simulation experiments
Energy Technology Data Exchange (ETDEWEB)
In order to study the two-phase natural circulation and flow termination during a small break loss of coolant accident in LWR, simulation experiments have been performed using two different thermal-hydraulic loops. The main focus of the experiment was the two-phase flow behavior in the hot-leg U-bend typical of BandW LWR systems. The first group of experiments was carried out in the nitrogen gas-water adiabatic simulation loop and the second in the Freon 113 boiling and condensation loop. Both of the loops have been designed as a flow visualization facility and built according to the two-phase flow scaling criteria developed under this program. The nitrogen gas-water system has been used to isolate key hydrodynamic phenomena such as the phase distribution, relative velocity between phases, two-phase flow regimes and flow termination mechanisms, whereas the Freon loop has been used to study the effect of fluid properties, ...
1987-01-01
Investigation of natural circulation two-phase flow behaviour in header manifold using CFD code
Energy Technology Data Exchange (ETDEWEB)
The three-dimensional (3-D), multiphase, computational fluid dynamic (CFD) code FLUENT is used to simulated two-phase flow behaviour in a CANDU header manifold under low (natural circulation) flow conditions. This behaviour was previously inferred from experimental data. The CFD simulations reported here are being used to support these inferences and to obtain a better understanding of phase distribution in the header manifold. The simulations seem to show that the vapor-water mixture models in the FLUENT code do not capture properly phase separation in the header and proper phase branching at the header-feeder connections that have been observed in experiments at low flows. The simulations using discrete-phase model in FLUENT, which tracks the pathlines of the individual vapor bubbles in the water continuum phase, show interesting, complicated and, in some cases, unexpected bubble trajectories from the point of injection ...
2006-07-01
Energy Technology Data Exchange (ETDEWEB)
The present paper explains the curve-fitting method developed as a method to estimate the geothermal equilibrium forming temperature. In the present method, that temperature is estimated by obtaining, by non-linear lest square, the model parameter to minimize the sum of remainders squared between the temperature actually measured after a lapse of certain time from the stoppage of mud water circulation and that calculated on the basis of Middleton model, mathematical model of temperature equilibrium well. In the Horner's plotting method currently in general use, temperature recovery data during a long period of about 120h are required for estimating the geothermal equilibrium forming temperature. However in the curve-fitting method, it is confirmed from the actual well data that the well recovery temperature is estimable from three logging data during 24h after the stoppage of mud water ...
1994-05-01
Flooded Underground Coal Mines: A Significant Source of Inexpensive Geothermal Energy
Energy Technology Data Exchange (ETDEWEB)
Many mining regions in the United States contain extensive areas of flooded underground mines. The water within these mines represents a significant and widespread opportunity for extracting low-grade, geothermal energy. Based on current energy prices, geothermal heat pump systems using mine water could reduce the annual costs for heating to over 70 percent compared to conventional heating methods (natural gas or heating oil). These same systems could reduce annual cooling costs by up to 50 percent over standard air conditioning in many areas of the country. (Formatted full-text version is released by permission of publisher)
2007-04-01
Volatile halocarbons as tracers of pulp mill effluent plumes
Energy Technology Data Exchange (ETDEWEB)
This work describes the use of volatile halocarbons in a pulp mill effluent, including chloroform, bromodichloromethane, and tri- and tetrachloroethylene, as tracers for the distribution and movements of effluent currents in a receiving water bay (Jackfish Bay) on the northern shore of Lake Superior. The results indicate the simplicity and usefulness of the technique and the significantly improved resolution of effluent plume delineation over the customary use of conductance profiles. Concentration patterns of the effluent volatiles suggest counterclockwise circulation of bay water that mixes with inflowing lake water at the eastern reach of the outer bay. The distribution of volatile contaminants is governed by the thermal regime of the receiving waters. During the summer months, the effluent plume wedges between the thermocline and epilimnion, mixing into the surface ...
1994-07-01
Bring fresh ideas to boiler startup procedures
Energy Technology Data Exchange (ETDEWEB)
This article describes innovations in new-boiler startups, based on experiences at United Development Group`s 50-MW Niagra cogeneration facility, Niagra Falls, NY. The plant comprises: a circulating coal fluidized bed boiler supplying steam to a nearby factory and electricity to the grid. Before operation the system was flushed with demineralized water, and the boiler degreased, the steam blow relied on a new procedure involving a continuous flow of steam. Startup was then initiated, following manufacturers heatup rate and soak times closely. After startup boiler tube sections were checked, and cleaned if necessary. 1 fig.
1996-05-01
Solar distillation as an appropriate technology tool in Haiti
Energy Technology Data Exchange (ETDEWEB)
Source Philippe (on the island of La Govave, near Haiti) is described in terms of climatic, sociological, agricultural and technical background. Because of drought conditions, it became necessary to develop a solar still to provide the town with sufficient fresh water. The still, which has been in operation since 1969, is described in some detail as is the construction process. Brackish and sea water are used to produce more than 1250 liters of fresh water each day. A windmill is used to pump the brackish water from a well to an elevated storage tank; it flows by gravity to solar still basins where it is vaporized, then condensed on a sloping glass surface and collected. Benefits of the solar still to the town's economy and health are discussed. Cost of the project was $17,000. 10 references. (MJJ)
1980-06-01
British Library Electronic Table of Contents (United Kingdom)
Phreatic groundwater pumping is affecting water availability for crops in areas with a shallow water table. This can reduce crop growth and so affect farm income. There is a need for a generic and transparent method to assess the agricultural damage caused by water table drawdown. This paper proposes such a method that consists of 'damage tables' relating agricultural production losses to the groundwater regime for different soil/crop combinations found in Northern Belgium. The damage tables are constructed based on numerous simulations with the agrohydrological model SWAP, in which the bottom boundary conditions are gradually changed to reflect different groundwater regimes. The credibility of the resulting metamodel is assessed in three ways: using (1) field data, (2) an existing local e...
2010-01-01
The importance of axial effects for borehole design of geothermal heat-pump systems
Energy Technology Data Exchange (ETDEWEB)
This paper studies the effects of axial heat conduction in boreholes used in geothermal heat pump systems. The axial effects are examined by comparing the results obtained using the finite and infinite line source methods. Using various practical design problems, it is shown that axial effects are relatively important. Unsurprisingly, short boreholes and unbalanced yearly ground loads lead to stronger axial effects. In one example considered, it is shown that the borehole length is 15% shorter when axial conduction effects are considered. In another example dealing with underground water freezing, the amount of energy that has to be removed to freeze the ground is three times higher when axial effects are considered. (author)
2010-04-15
Hydrodynamics induced vibration to trash-racks
International Nuclear Information System (INIS)
In conventional power plants trash-racks are provided at the intakes to protect the turbines. In pumped storage plants, the draft tube or tailrace must also have trash-racks to protect the units while pumping. Because the loads believed to cause many failures of trash-racks are dynamic in nature, it is important to understand the dynamic characteristics of trash-racks structures in general and a single rack in particular. The classical added-mass solution structure-fluid dynamic interaction is known as an approximate solution procedure. An accurate added-mass approach mixed with implementation in finite element framework is proposed. In this proposal, experimental conclusions, supported by theory, led to presentation of more accurate results in vibration of trash-racks. This numerical solution as a powerful method to solve such a complex problem can be employed to carry out dynamic characteristics of these structures while vibrating in ...
2002-12-01
Horizontal ground coupled heat pump: Thermal-economic modeling and optimization
Energy Technology Data Exchange (ETDEWEB)
The modeling and optimizing processes of a Ground Coupled Heat Pump (GCHP) with closed Horizontal Ground Heat eXchanger (HGHX) are presented in this paper. After thermal modeling of GCHP including HGHX, the optimum design parameters of the system were estimated by minimizing a defined objective function (total of investment and operation costs) subject to a list of constraints. This procedure was performed applying Genetic Algorithm technique. For given heating/cooling loads and various climatic conditions, the optimum values of saturated temperature/pressure of condenser and evaporator as well as inlet and outlet temperatures of the water source in cooling and heating modes were predicted. Then, for our case study, the design parameters as well as the configuration of HGHX were obtained. Furthermore, the sensitivity analysis of change in the total annual cost of the system and optimum design parameters with the climatic conditions, ...
2010-12-15
Experimental evaluation of a non-azeotropic working fluid for geothermal heat pump system
Energy Technology Data Exchange (ETDEWEB)
Geothermal energy resources are found in many countries. A reasonable and efficient utilization of these resources has been a worldwide concern. The application of geothermal heat pump systems (GHPS) can help increase the efficiency of using geothermal energy and reduce the thermal pollution to the earth surface. However, this is only possible with a proper working fluid. In this paper, a non-azeotropic working fluid (R290/R600a/R123) is presented for a GHPS where geothermal water at 40-45{sup o}C and heating network water at 70-80{sup o}C serve as the low and high temperature heat sources. Experimental results show that the coefficient of performance (COP) of a GHPS using the working fluid is above 3.5 with the condensation temperature above 80{sup o}C and the condensation pressure below 18 bar, while the temperature of the geothermal water is reduced from 40-46{sup o}C to 31-36{sup o}C. (author)
2004-06-01
Experimental evaluation of a non-azeotropic working fluid for geothermal heat pump system
International Nuclear Information System (INIS)
Geothermal energy resources are found in many countries. A reasonable and efficient utilization of these resources has been a worldwide concern. The application of geothermal heat pump systems (GHPS) can help increase the efficiency of using geothermal energy and reduce the thermal pollution to the earth surface. However, this is only possible with a proper working fluid. In this paper, a non-azeotropic working fluid (R290/R600a/R123) is presented for a GHPS where geothermal water at 40-45 deg. C and heating network water at 70-80 deg. C serve as the low and high temperature heat sources. Experimental results show that the coefficient of performance (COP) of a GHPS using the working fluid is above 3.5 with the condensation temperature above 80 deg. C and the condensation pressure below 18 bar, while the temperature of the geothermal water is reduced from 40-46 deg. C to 31-36 deg. C.
2004-06-01
International Nuclear Information System (INIS)
A study has been performed of the initial corrosion of support structure alloys in crevices of various geometries, when galvanically coupled to alloy 600. Corrosion rates were monitored continuously by measuring the galvanic current flowing in each couple, transduced by a zero impedance ammeter. Experiments were performed in a single-pass flowing electrolyte system, with AVT water pumped through alloy 600 tubing past the orifice of each crevice. Fourteen crevices were studied simultaneously in two parallel flow arms containing seven specimens each. The steady state AVT water pH/hydrazine/oxygen concentrations were controlled by microcomputer, allowing the effect of secondary water chemistry on the corrosion rate to be studied easily. Control of the crevice electrolyte composition was achieved by separately pumping electrolyte, at a low rate, directly into the crevices of the seven ...
1985-03-01
Energy Technology Data Exchange (ETDEWEB)
Energy savings performance contracting (ESPC) is now receiving greater attention as a means of implementing large-scale energy conservation projects in housing. Opportunities for such projects exist for military housing, federally subsidized low-income housing, and planned communities (condominiums, townhomes, senior centers), to name a few. Accurate prior (to construction) estimates of the energy savings in these projects reduce risk, decrease financing costs, and help avoid post-construction disputes over performance contract baseline adjustments. This paper demonstrates an improved method of estimating energy savings before construction takes place. Using an engineering model calibrated to pre-construction energy-use data collected in the field, this method is able to predict actual energy savings to a high degree of accuracy. This is verified with post-construction energy-use data from a geothermal heat pump ESPC at Fort Polk, Louisiana. This method also allows ...
1998-10-01
Energy Technology Data Exchange (ETDEWEB)
Energy savings performance contracting (ESPC) is now receiving greater attention as a means of implementing large-scale energy conservation projects in housing. Opportunities for such projects exist for military housing, federally subsidized low-income housing, and planned communities (condominiums, townhomes, senior centers), to name a few. Accurate prior (to construction) estimates of the energy savings in these projects reduce risk, decrease financing costs, and help avoid post-construction disputes over performance contract baseline adjustments. This paper demonstrates an improved method of estimating energy savings before construction takes place. Using an engineering model calibrated to pre-construction energy-use data collected in the field, this method is able to predict actual energy savings to a high degree of accuracy. This is verified with post-construction energy-use data from a geothermal heat pump ESPC at Fort Polk, Louisiana. This method also allows ...
1998-01-01
CFD code fluent turbulence models application. Ansaldo's prototype modeling
International Nuclear Information System (INIS)
Among others, one of the main activities in the Nuclear Engineering and Fluid Mechanics Department of the Engineering School in Bilbao, is the study of liquid metals behavior. And for this purpose the CFD code FLUENT is being used. Currently, the code is being applied to the use of Lead-Bismuth eutectic (LBE) as the coolant of an accelerator driven system (ADS) and also as the target for a neutron source. In this paper, ANSALDO's Energy Amplifier Demonstration Facility is simulated, paying attention only on the coolant. As it will be later explained, natural convection is a very important issue, because the philosophy for safety systems in nuclear devices tends to consider passive technologies. The purpose is to avoid electrical machines like pumps, so the core should remain coolable, even if there is a blackout. To get this natural circulation, heat transfer plays a main role, and as turbulence enhances the heat transfer, it is important to ...
2001-12-04
An advanced experimental technique has been developed to simulate two-phase flow behavior in a light water reactor (LWR). The technique applies three kinds of methods; (1) use of sulfur-hexafluoride (SF6) gas and ethanol (C2H5OH) liquid at atmospheric temperature and a pressure less than 1.0MPa, where the fluid properties are similar to steam-water ones in the LWR, (2) generation of bubble with a sintering tube, which simulates bubble generation on heated surface in the LWR, (3) measurement of detailed bubble distribution data with a bi-optical probe (BOP), (4) and measurement of liquid velocities with the tracer liquid. This experimental technique provides easy visualization of flows by using a large scale experimental apparatus, which gives three-dimensional flows, and measurement of detailed spatial distributions of two-phase flow. With this technique, we have carried out experiments simulating two-phase flow behavior in a single-channel ...
2009-02-01
Experimental and theoretical studies on humidification-dehumidification-desalination
Energy Technology Data Exchange (ETDEWEB)
The shortage of fresh water is increasing at alarming levels, even in temperate zones. Desalination of brackish and seawater is being considered as a solution to growing water demands. Seawater desalination can be accomplished through reverse osmosis, vapor compression, vapor absorption and thermally driven systems. The most suitable process for large-scale desalination plants is successive brine evaporation-condensation with intermediate heat recovery. However, higher process efficiency could be achieved. The use of low temperature heat sources in seawater desalination requires an efficient method of evaporation and condensation at relatively low vapor pressures. This could be achieved in a humidification-dehumidification process using circulated air to enhance evaporation of water. Simulation models, however, neglect either the heat of evaporation or the changes in air and water ...
2006-07-01
Processing method and processing facility for carbon steel parts in nuclear power plant
International Nuclear Information System (INIS)
In a closed circuit formed by bypassing pipelines connected to carbon steel parts, low oxygen coolants pass there through during operation. A solution containing ions of metals more noble than iron are circulated to bring the solution into contact with the carbon steel surface of the inner wall of the parts to form a deposition membrane of the metal more noble than iron on the surface to prevent acceleration of corrosion of the carbon steel parts due to low oxygen coolants. The solution containing ions of metals more noble than iron is a solution of palladium nitrate containing ions of platinum elements. This operation is conducted under a temperature condition of from 50degC to 150degC. In addition, the metal ion concentration of the solution circulating in the closed circuit is measured, it is compared with metal ion concentration previously determined, and the results are feed back to a means for controlling water ...
1996-11-27
Energy Technology Data Exchange (ETDEWEB)
The presentation summarises the highlights of experimental results obtained for VVER type horizontal steam generator heat transfer, primary side flow pattern, and mixing in the hot collector during secondary side boil-off with primary at single-phase natural circulation. The experiments were performed using the PACTEL facility with Large Diameter (LD) steam generator models, with collector instrumentation designed specifically for these tests. The key findings are as follows: (1) the primary to secondary heat transfer degrades as the secondary water inventory is depleted, following closely the wetted tube area; (2) a circulatory flow pattern exists in the tube bundle, resulting in reversed flow (from cold to the hot collector) in the lower part of the tube bundle, and continuous flow through the upper part, including the tubes that have already dried out; and (3) mixing of the hot leg flow entering the hot collector and reversed, cold, tube ...
1997-12-31
Energy Technology Data Exchange (ETDEWEB)
The atmosphere and the biosphere are inherently coupled to one another. Atmospheric surface state variables such as temperature, winds, water vapor, precipitation, and radiation control biophysical, biogeochemical, and ecological processes at the surface and subsurface. At the same time, surface fluxes of momentum, moisture, heat, and trace gases act as time-dependent boundary conditions providing feedback on atmospheric processes. To understand such phenomena, a coupled set of interactive models is required. Costs are still prohibitive for computing surface/subsurface fluxes directly for medium-resolution atmospheric general circulation models (AGCMs), but a technique has been developed for testing large-scale homogeneity and accessing surface parameterizations and models to reduce this computational cost and maintain accuracy. This modeling system potentially bridges the observed spatial and temporal ranges yet allows the incorporation of ...
1993-12-31
International Nuclear Information System (INIS)
A fluidic pump comprises a two-diode pump having a first displacement vessel, a third diode connected to receive output from the two-diode pump through a delivery line and discharge to an outlet, and a second displacement vessel connected to the delivery line. There is a feed tank at a greater height than the two-diode pump, and a drive unit for alternately pressurising and venting the first and second displacement vessels. The drive pressure required to operate the pump can be of the order of half that for a single stage 2-diode pump. (author).
1988-05-19
LOBI/B-R1M, Loop for Blowdown Investigation, PWR Single-Ended Cold-Leg Break Experiment B EXP.B
International Nuclear Information System (INIS)
1 - Description of test facility: The LOBI facility is a 1/700 scale model of a four loop PWR and has two primary loops, the intact loop representing three loops and the broken loop representing one loop of a four-loop PWR. The reactor pressure vessel model contains an electrically heated rod-bundle with 64 rods and a heated length of 3.9 m. The nominal heating power is 5.3 MW. The downcomer is of annular shape. An upper head simulator is connected to the vessel. Each of the two primary loops contains a pump and a steam generator. The different mass flows in the loops are established by the pump speeds, since the two pumps are identical. Heat is removed from the steam generators by a secondary system. ECC water can be supplied from two accumulators, one for each loop. Cold or hot leg as well as combined injection can be simulated. The LOBI test facility is the only high pressure integral test facility ...
Energy Technology Data Exchange (ETDEWEB)
The Lincoln Public School District, in Lincoln, Nebraska, recently installed vertical-bore geothermal heat pump systems in four, new, elementary schools. Because the district has consistent maintenance records and procedures, it was possible to study repair, service and corrective maintenance requests for 20 schools in the district. Each school studied provides cooling to over 70% of its total floor area and uses one of the following heating and cooling systems: vertical-bore geothermal heat pumps (GHPs), air-cooled chiller with gas-fired hot water boiler (ACUGHWB), water-cooled chiller with gas-fired hot water boiler (WCCYGHWB), or water-cooled chiller with gas-fired steam boiler (WCUGSB). Preventative maintenance and capital renewal activities were not included in the available database. GHP schools reported average total costs at 2.13 cents/ft{sup 2}-yr, ...
1999-06-19
Solar desalination using humidification dehumidification processes. Pt. 1. A numerical investigation
Energy Technology Data Exchange (ETDEWEB)
A numerical investigation of a humidification dehumidification desalination (HDD) process using solar energy is presented. The HDD system consists mainly of a concentrating solar water heating collector, flat plate solar air heating collector, humidifying tower and dehumidifying exchanger. Two separate circulating loops constitute the HDD system, the first for heating the feed water and the second for heating air. A mathematical model is developed, simulating the HDD system, to study the influence of the different system configurations, weather and operating conditions on the system productivity. The model validity is examined by comparing the theoretical and experimental results of the same authors. It is found that the results of the developed mathematical model are in good agreement with the experimental results and other published works. The results show also that the productivity of the unit is strongly influenced by ...
2004-05-01
Energy Technology Data Exchange (ETDEWEB)
A numerical investigation of a humidification dehumidification desalination (HDD) process using solar energy is presented. The HDD system consists mainly of a concentrating solar water heating collector, flat plate solar air heating collector, humidifying tower and dehumidifying exchanger. Two separate circulating loops constitute the HDD system, the first for heating the feed water and the second for heating air. A mathematical model is developed, simulating the HDD system, to study the influence of the different system configurations, weather and operating conditions on the system productivity. The model validity is examined by comparing the theoretical and experimental results of the same authors. It is found that the results of the developed mathematical model are in good agreement with the experimental results and other published works. The results show also that the productivity of the unit is strongly influenced by ...
2004-05-01
Zero-G two phase flow regime modeling in adiabatic flow
Energy Technology Data Exchange (ETDEWEB)
Two-phase flow, thermal management systems are currently being considered as an alternative to conventional, single phase systems for future space missions because of their potential to reduce overall system mass, size, and pumping power requirements. Knowledge of flow regime transitions, heat transfer characteristics, and pressure drop correlations is necessary to design and develop two-phase systems. This work is concerned with microgravity, two-phase flow regime analysis. The data come from a recent sets of experiments. The experiments were funded by NASA Johnson Space Center (JSC) and conducted by NASA JSC with Texas A M University. The experiment was on loan to NASA JSC from Foster-Miller, Inc., who constructed it with funding from the Air Force Phillips Laboratory. The experiment used R12 as the working fluid. A Foster-Miller two phase pump was used to circulate the two phase mixture and allow separate measurements of ...
1993-01-15
Zero-G two phase flow regime modeling in adiabatic flow
International Nuclear Information System (INIS)
Two-phase flow, thermal management systems are currently being considered as an alternative to conventional, single phase systems for future space missions because of their potential to reduce overall system mass, size, and pumping power requirements. Knowledge of flow regime transitions, heat transfer characteristics, and pressure drop correlations is necessary to design and develop two-phase systems. This work is concerned with microgravity, two-phase flow regime analysis. The data come from a recent sets of experiments. The experiments were funded by NASA Johnson Space Center (JSC) and conducted by NASA JSC with Texas A ampersand M University. The experiment was on loan to NASA JSC from Foster-Miller, Inc., who constructed it with funding from the Air Force Phillips Laboratory. The experiment used R12 as the working fluid. A Foster-Miller two phase pump was used to circulate the two phase mixture and allow separate ...
1993-01-10
Hydroelectric power in Switzerland: large growth potential by increasing the installed power
International Nuclear Information System (INIS)
Due to its important hydroelectric power generation facilities (about 525 plants with a total power of 13,314 MW producing about 35.3 TWh annually) Switzerland plays an important role in the interconnected European power system. Large artificial storage lakes in the Swiss Alps can generate peak power during hours of highest demand: 9700 MW are available from accumulated energy and the total power of pumped-storage facilities amounts to 1700 MW. The latter allow refilling the reservoirs at periods of low power demand and generating power at periods of peak demand. In the case of favorable conditions, the yearly average power production could be increased by 6% and the production during the winter period (October to March) by 20% by the year 2020. However, looking forward to the year 2050, the annual production is expected to decrease by 3% despite a possible extension of hydropower. This decrease is due to the enforcement of the minimum residual ...
Simulation of natural circulation in PGV-1000 steam generator
Energy Technology Data Exchange (ETDEWEB)
The PGV-1000 secondary side natural circulation calculation results for steady-state operational conditions and their analysis using the data of actual NPP circulation investigation are presented. (3 refs., 3 figs., 3 tabs.).
1993-12-31
Simulation of natural circulation in PGV-1000 steam generator
International Nuclear Information System (INIS)
The PGV-1000 secondary side natural circulation calculation results for steady-state operational conditions and their analysis using the data of actual NPP circulation investigation are presented. (3 refs., 3 figs., 3 tabs.).
1992-09-29
Telephone exchange Feutersoey - first pilot plant of the PTT with solar collectors
Energy Technology Data Exchange (ETDEWEB)
In the course of this year six local exchange offices with alternative heating and hot water plants were started up in Switzerland. They are all of the same building type, designed for not more than 1000 telephone subscribers and for the same architectural conditions. However, the buildings are situated in different areas of the country and are thus subject to different environmental conditions. Solar collectors supplemented by electricity boilers are fitted to two of these objects. Heat pumps are operated in two other exchange offices while the last two are equipped with electric heating devices. For purposes of comparison two new test plants of the same size with oil heating devices are set up.
1981-01-01
Removal of uranium by biosorption
Energy Technology Data Exchange (ETDEWEB)
The technology developed here will exploit the ability of microorganisms to remove dissolved metals from aqueous solutions. Microbial sorbents for uranium will be immobilized biosorbents will be deployed ex situ within flow-through reactors for the continuous or semicontinuous treatment of recovered wastewaters. The proposed technology will primarily be applied within a pump-and-treat process using immobilized biosorbents for the large-scale, long-term remediation of uranium-laden surface water or groundwater impoundments (environmental restoration). The technology may be equally useful as an ``end-of-pipe`` treatment of process effluents (waste management). Successful operation of this process will achieve immobilization of the targeted waste and accompanying volume reduction.
1993-06-01
International Water Power and Dam Construction Handbook 1993
Energy Technology Data Exchange (ETDEWEB)
In this handbook, technical reports on a number of hydro plants under construction are provided. In addition tables of compiled data are presented on a world-wide basis for the following: turbine and hydro generator contracts; hydropower resource potential and development; pumped storage plants; the major dams and hydro plants; roller compacted concrete dams and concrete faced rockfill dams; small hydropower. An address database of international organizations of relevance to hydropower development, national power authorities and nation committees of the International Commission an Large Dams is included. A final and major section of the handbook is a buyer's guide providing extensive company data and information on products and services. (UK)
1993-01-01
Energy nomographs as a design tool for daylighting
Energy Technology Data Exchange (ETDEWEB)
The purpose of this paper is to inform commercial building designers about an energy analysis tool which can aid them in making appropriate decisions about daylighting. The energy nomographs are an energy design tool which calculate the annual energy consumption of commercial buildings, including lighting, heating, cooling, domestic hot water, fans, pumps, and miscellaneous items. This paper specifically discusses the daylighting aspects of the tool. The calculation procedure is presented with an example to explain how this design tool can be used to make good energy decisions early in the design process.
1984-01-01
Restoration of a forested wetland ecosystem in a thermally impacted stream corridor
Energy Technology Data Exchange (ETDEWEB)
The Savannah River Swamp is a 3,020 Ha forested wetland on the floodplain of the Savannah River and is located on the Department of Energy`s Savannah River Site (SRS). Major impacts to the swamp hydrology occurred with the completion of the production reactors and one coal-fired powerhouse at the SRS in the early 1950`s. Water was pumped from the Savannah River, through secondary heat exchangers of the reactors, and discharged into three of the tributary streams that flow into the swamp. This continued from 1954 to 1988 at various levels. The sustained increases in water volume resulted in overflow of the original stream banks and the creation of additional floodplains. Accompanying this was considerable erosion of the original stream corridor and deposition of a deep silt layer on the newly formed delta. Heated water was discharged directly into Pen Branch and water temperature in ...
1995-09-01
Transverse Pumping with Diode Lasers
... Title : Transverse Pumping with Diode Lasers. Descriptive Note : Technical rept. ... Subject Categories : LASERS AND MASERS. ...
1989-01-06
Hydroelectric Power Plants Electrical Design
... Treatment of electrical systems for pumped storage plants is not covered in the manual, although much of the information is applicable to pumped ...
1994-06-30
Wax and hydrate control with electrical power
Energy Technology Data Exchange (ETDEWEB)
Electrical heating of subsea flowlines is an effective way to prevent wax and hydrate information, especially for long transportation distances and in low-temperature deep water. Systems are available for use in conjunction with bundles, pipe-in-pipe, and wet-thermal-insulation systems. These systems provide environmentally friendly fluid-temperature control without chemicals or flaring for pipeline depressurizing. Enhanced production is achieved because no time is lost by unnecessary depressurizing, pigging, heating-medium circulation, or removal of hydrate and wax blockages. The seabed temperature at 100-m and greater water depths may range from 7 to {minus}1.5 C, causing a rapid cooling of the hot well streams being transported in subsea flowlines. Under these supercooling conditions, vulnerable crude oils and multiphase compositions will deposit wax and asphalts; also the gas/water phase may freeze ...
1997-08-01
Energy Technology Data Exchange (ETDEWEB)
Acid mine drainage represents one of the most important environmental problem facing the mining industry. If the tailings contain sulphur, acid mine drainage will be generated as soon as the tailings are exposed to oxygen. In this paper, the authors discussed a technique for the storage of acid mine drainage generating tailings that delays and even eliminates the occurrence. It was suggested that tailings should be piled by incorporating, at regular intervals, compacted waste rock. Thermal convection and diffusion will prevent oxygen from reaching the tailings, and limit water circulation. The modelling of transfer processes (heat, water, oxygen) in a well known tailings dump, the Doyon Mine, was performed, and the results compared to the modelling where compacted waste rock had been incorporated at regular intervals. The results indicated that by remaining saturated, the layers acted as capillary barriers preventing oxygen ...
2000-07-01
The long operating cycle simplified boiling water reactor is a reactor concept that pursues both safety and the economy by employing a natural circulation reactor core without a refueling, a passive decay heat removal, and an integrated building for the reactor and turbine. Throughout the entire spectrum of the design basis accident, the reactor core is kept covered by the passive emergency core cooling system. The decay heat is removed by the conventional active low-pressure residual heat removal system. As for a postulated severe accident, the suppression pool water floods the lower part of the reactor pressure vessel (RPV) in the case when core damage occurs, and the in-vessel retention that keeps the melt inside the RPV is achieved by supplying the coolant. The containment adopts a parallel-double-steel-plate structure similar to a hull structure, which contains coolant between the inner and outer walls to absorb the ...
2003-07-15
Primary coolant depressurization facility
Energy Technology Data Exchange (ETDEWEB)
In a PWR type reactor, a primary coolant circuit system using a steam generator is adopted in order to accelerate depressurization of a primary coolant circuit upon small rupture LOCA in which the pressure of the primary coolant circuit is moderately depressurized. A secondary coolant circuit depressurization valve is disposed to a main steam pipeline. The valve has a performance of automatically opening to remove heat by evaporation of water stored in SG for a short period of time when the pressure in the primary circuit is decreased to about 50kg/cm[sup 2] upon occurrence of LOCA or the like. Then, the secondary side of the SG is depressurized to about atmospheric pressure and gravitational water injection from a condensate tank is started. Further, a gas vent valve is disposed to a water chamber of the steam generator. The valve has a performance of automatically opening to discharge incondensible gas mixed to the ...
1992-10-14
Ocean thermal energy conversion (OTEC) plants discharge large volumes of cold water into the upper ocean. A three-dimensional, limited-area model was developed to investigate the regional influence of the far-field effluent plume created by the negatively buoyant discharge. The model was applied to discharges from a 40-MW/sub e/ OTEC plant into coastal waters characterized by various ambient ocean conditions. A typical ambient temperature structure and nutrient distribution, as well as the behavior of the effluent plume itself, were strongly modified by the discharge-induced circulation. Although temperature perturbations in the plume were small, upward entrainment of nutrients from below the thermocline was significant. The regional influence of discharges from an 80-MW/sub e/ OTEC plant, the interactions between the discharges from two adjacent 40-MW/sub e/ OTEC plants, and the effects of coastal boundary and bottom ...
1985-07-01
International Nuclear Information System (INIS)
On all steam turbines operating with condensation the air leakage penetrating from the part of the plant which is under vacuum must be eliminated, in order to maintain the vacuum created by physical conditions. In order to attain effective air bleed-off, the water-steam-air mixture is conveyed via the super-cooling bundles in the condenser. In this way the steam partial pressure decreases and the air partial pressure increases at a constant condenser pressure. In this procedure the mixture is supercooled by about 4"0C compared with the saturate steam temperature appertaining to the condenser pressure. The values of volume of air leakage are the result of a year's experience on existing plant. (orig.).
Final ROI Report - Technology Transfer of Waste-Reducing Groundwater Sampling Systems
Energy Technology Data Exchange (ETDEWEB)
This report presents the findings of a U.S. DOE Environmental Management technology transfer initiative of waste-reducing ground water sampling systems between Savannah River Site (SRS) and Lawrence Livermore National Laboratory (LLNL) which occurred during fiscal years 2001 and 2002. The report describes the collaboration between the two sites, the deployment of the Savannah River Site Purge Water Management System at LLNL, the changes made to that system for use at LLNL, and documents the return-on-investment derived from the system's use at LLNL as well as other benefits generated through this inter-laboratory collaboration. An evaluation of the deployment of the LLNL EasyPump sampling technology at SRS will be covered in a separate report from SRS.
2002-09-30
International Nuclear Information System (INIS)
The loss of seal of the H9 channel in vacuum, freeing the entire cross section of the front part, leads to a fast leak that progresses rapidly. The effect of depressurizing the reflector can leads to shutdown of the shutdown rod pumps. The source changer associated with the channel fills completely before the valve closes. All of the leak water remains contained within the source changer containment. After the valves open, cooling of the fuel element is handled by natural convection, requiring a reversal of the flow between the plates. This changeover, which takes place at a relatively low pressure level, could lead to local boiling in the fuel element. Consequently, irreversible transformations cannot be excluded as possibilities for the fuel element and even for the control rod. Subsequently, the can is refilled with heavy water with establishment of the usual pressure levels.
Energy Technology Data Exchange (ETDEWEB)
This final report for the Swiss Federal Office of Energy (SFOE) examines a project that aimed to define standard solutions for use in buildings built to meet Minergie low energy consumption standards. These standard solutions are to provide a way of meeting Minergie standards in an easy way and thus further the use of the standard and also assure quality at the same time. The report describes how the solutions were developed on the basis of a selection of existing Minergie buildings. For various combinations of heating systems - wood, wood/solar, heat pumps (brine-water and air-water), gas/solar and oil/solar - the appropriate U-values for various building elements are listed. The resulting Minergie forms and guides are listed.
2003-07-01
Construction progress of the cooling & ventilation in the LHC project
After the LEP dismantling Phase the Cooling and Ventilation Group has started the LHC construction work. Year 2001 through to 2004 will certainly be the most important period of activity for the CV group in the erection phase The author will report on the current works that are in progress on the different LHC Points distinguishing between the Ventilation and the Water Cooling installations. The Ventilation work completed in the new surface buildings in Points 1, 4,5,6 and 8. The work for the Cooling plants comprehend to the pumping stations, the cooling towers and the chilled water production stations in Points 1 and 5, For all of these activities, an updated report of the progress the work, the planning and of the expenses are given. Finally, a brief overview of the future activities is presented.
2002-01-01
Construction Progress of the Cooling and Ventilation in the LHC Project
The Cooling and Ventilation Group has started the LHC construction work in September 1999 and will get into full activity when LEP will be stopped and dismantled: in total 12 major contracts for an amount of about 120 MCHF will be established to build the needed installations for the LHC. The author will report on the current works that are in progress on the different LEP Points distinguishing between the Ventilation and the Water Cooling installations. The Ventilation work, completed in the new surface buildings in Points 18, is currently held in Points 4 and 5. Point 1 will follow in the near future. The work for the Cooling plants comprehend the pumping stations, the cooling towers and the chilled water production stations in Points 1 and 5, the buried pipes in Points 1 and 4. For all of these activities, an updated report of the progress of the work, of the planning and of the expenses is given. Finally, a short ...
2001-01-01
Stationary low power reactor No. 1 (SL-1) accident site decontamination & dismantlement project
The Army Reactor Area (ARA) II was constructed in the late 1950s as a test site for the Stationary Low Power Reactor No. 1 (SL-1). The SL-1 was a prototype power and heat source developed for use at remote military bases using a direct cycle, boiling water, natural circulation reactor designed to operate at a thermal power of 3,000 kW. The ARA II compound encompassed 3 acres and was comprised of (a) the SL-1 Reactor Building, (b) eight support facilities, (c) 50,000-gallon raw water storage tank, (d) electrical substation, (e) aboveground 1,400-gallon heating oil tank, (f) underground 1,000-gallon hazardous waste storage tank, and (g) belowground power, sewer, and water systems. The reactor building was a cylindrical, aboveground facility, 39 ft in diameter and 48 ft high. The lower portion of the building contained the reactor pressure vessel surrounded by gravel shielding. Above the pressure vessel, ...
1995-11-01
British Library Electronic Table of Contents (United Kingdom)
Background: Ecchymosis, oedema, haematoma and pain after SMAS-based facelift surgery are all the direct result of the physical trauma of surgery and subsequent inflammatory response. Hilotherapy is a novel form of cryotherapy that purports to minimise these events through single-use face masks circulating cooled, sterile water. This study was performed to assess the validity of Hilotherapy in this population of patients. Methods: Over 14 weeks fifty consecutive patients were randomised to post-operative facial cooling with Hilotherapy or management with standard dressings alone, while fifteen subsequent, consecutive patients were randomised to cooling of one side of the face but not the other. Assessment of ecchymosis, oedema, haematoma and pain was performed independently by clinical staf...
2011-01-01
Comparative planetology, climatology and biology of Venus, Earth and Mars
British Library Electronic Table of Contents (United Kingdom)
Spacecraft studies of the three terrestrial planets with atmospheres have made it possible to make meaningful comparisons that shed light on their common origin and divergent evolutionary paths. Early in their histories, all three apparently had oceans and extensive volcanism; Mars and Earth, at least, had magnetic fields, and Earth, at least, had life. All three currently have climates determined by energy balance relationships involving carbon dioxide, water and aerosols, regulated by solar energy deposition, atmospheric and ocean circulation, composition, and cloud physics and chemistry. This paper addresses the extent to which current knowledge allows us to explain the observed state of each planet, its planetology, climatology and biology, within a common framework. Areas of ignorance...
2011-01-01
Climate change/variability implications on hydroelectricity generation in the Zambezi River Basin
British Library Electronic Table of Contents (United Kingdom)
The study has analysed the effects of various factors on hydroelectric power generation potential to include climate change/variability, water demand, and installation of proposed hydroelectric power schemes in the Zambezi River Basin. An assessment of historical (1970?2000) power potential in relation to climate change/variability at existing hydro electric power schemes(Cahora Bassa, Kariba, Kafue Gorge and Itezhi-Tezhi) in the Zambezi River Basin was conducted. The correlation of hydroelectric power potential with climate change/variability aimed at observing the link and extent of influence of the latter on the former was investigated. In order to predict the future outlook of hydro electric power potential, General Circulation Models (GCM) were used to generate projected precipitation...
2011-01-01
An overview of physical and biogeochemical processes and ecosystem dynamics in the Taiwan Strait
British Library Electronic Table of Contents (United Kingdom)
The Taiwan Strait is an important channel in the west Pacific Ocean transporting water and chemical constituents between the East China Sea and the South China Sea. Due to its complex bottom topography, alternating monsoon forcing and conjunction of several current systems [such as the Zhejiang-Fujian (Zhe-Min) Coastal Current, the Kuroshio intrusion and the extension of the South China Sea Warm Current], the physical and biogeochemical processes and ecosystem dynamics in the Taiwan Strait vary significantly both in space and in time. Our recent interdisciplinary studies, combining in situ and remote sensing observations with numerical modeling, allow us to address several important issues concerning the Taiwan Strait. The temporal and spatial variation of circulation in the Taiwan Strait ...
2011-01-01
Session 1: Geothermal Pumping Systems and Two-Phase Flow Studies
Energy Technology Data Exchange (ETDEWEB)
Improvements in electric submersible pumping systems have resulted in a demonstrated downhole running life of one year for low horsepower units operating in 180 C brine. The implementation of a prototype pressurized lubrication system to prevent brine intrusion and loss of lubricating oil from the motor and protector sections has been successfully tested. Second generation pressurized lubrication systems have been designed and fabricated and will be utilized in downhole production pumping tests during FY84. Pumping system lifetime is currently limited by available power cable designs that are degraded by high-temperature brine. A prototype metal-sheathed power cable has been designed and fabricated and is currently undergoing destructive and nondestructive laboratory testing. This cable design has the potential for eliminating brine intrusion into the power delivery system through the use of a hermatically sealed cable from ...
1983-12-01
Development of the hydropower sector in Japan
Energy Technology Data Exchange (ETDEWEB)
Japan's first water power station to provide public power was the Keage plant (maximum output 160 kW) which began operation in 1891. The installed capacity of pure hydro plants reached 20 481 MW in March 1991; pumped-storage powerplants account for 17 004 MW, making a total of 37 483 MW. Pumped-storage thus represents 45 per cent of total hydro capacity. Pure hydro plants under construction at the end of March 1990 totalled 75, representing 968 MW of capacity. There were also seven pumped-storage plants under construction (each more than 300 MW). The latest survey to establish the hydro potential of Japan indicated the gross theoretical hydro potential to be 717 600 GWh/year and the exploitable potential to be 130 524 GWh/year. Of this exploitable potential, 60 per cent is in operation and 3 per cent is under construction. The exploitable potential represents 4551 pure hydro plants, with a ...
1991-11-01
Oil cable pumping plant. Pumpestasjon
Energy Technology Data Exchange (ETDEWEB)
The invention deals with a pumping plant for oil filled power cables. An air driven piston type pump is used as primary pump. A PLS (Programmable Logic control System) is used to control the oil flow to the cable(s). Improvements of the pump includes means for ensuring that the pump piston is operated also at low pressure and flow, and means for sealing off the piston rod to ensure maximum life of seals, to facilitate detection of possible leakages and to avoid contamination of the cable oil. 3 figs.
1988-12-27
Ventilation test at Mont Terri. Geoelectric monitoring of the opalinus clay desaturation. Phase 2
Energy Technology Data Exchange (ETDEWEB)
Between December 2001 and May 2004, a ventilation experiment (VE) was performed in the Mont Terri Underground Research Laboratory (URL) and co-financed by the Commission of the European Communities. The objective was to investigate the desaturation of consolidated clay formations in consequence of the ventilation of underground openings of a repository in such a formation. The results of the geoelectric measurements performed in the second phase of the Mont Terri ventilation test can be summarized as follows: Geoelectric tomography has been found suitable for monitoring ventilation-induced saturation changes in the Opalinus clay. During ventilation with dry air a desaturation down to below 50% could be detected in both desaturation cycles. The desaturated zone extends less than 0.5 m into the rock around the microtunnel. During the second resaturation phase, ventilation with humid air led to quick resaturation at the tunnel surface, while resaturation of the rock mass took months. The ...
2008-04-15
Ventilation test at Mont Terri. Geoelectric monitoring of the opalinus clay desaturation. Phase 2
International Nuclear Information System (INIS)
Between December 2001 and May 2004, a ventilation experiment (VE) was performed in the Mont Terri Underground Research Laboratory (URL) and co-financed by the Commission of the European Communities. The objective was to investigate the desaturation of consolidated clay formations in consequence of the ventilation of underground openings of a repository in such a formation. The results of the geoelectric measurements performed in the second phase of the Mont Terri ventilation test can be summarized as follows: Geoelectric tomography has been found suitable for monitoring ventilation-induced saturation changes in the Opalinus clay. During ventilation with dry air a desaturation down to below 50% could be detected in both desaturation cycles. The desaturated zone extends less than 0.5 m into the rock around the microtunnel. During the second resaturation phase, ventilation with humid air led to quick resaturation at the tunnel surface, while resaturation of the rock mass took months. The ...
Ultra-high pressure water jet: Baseline report
International Nuclear Information System (INIS)
The ultra-high pressure waterjet technology was being evaluated at Florida International University (FIU) as a baseline technology. In conjunction with FIU's evaluation of efficiency and cost, this report covers the evaluation conducted for safety and health issues. It is a commercially available technology and has been used for various projects at locations throughout the country. The ultra-high pressure waterjet technology acts as a cutting tool for the removal of surface substrates. The Husky trademark pump feeds water to a lance that directs the high pressure water at the surface to be removed. The safety and health evaluation during the testing demonstration focused on two main areas of exposure. These were dust and noise. The dust exposure was found to be minimal, which would be expected due to the wet environment inherent in the technology, but noise exposure was at a significant level. Further testing for noise is ...
1997-07-01
Management and optimization of the CPCU network working
Energy Technology Data Exchange (ETDEWEB)
The CPCU steam distribution network is supplemented by a return network for the condensation water. The data system installed in 1988 provides, for the real time, management of the function of the two networks and a reduction in production costs. For the steam, data required in the network, the boiler houses and from external sources are processed by local network of five microprocessors and permit: - with time delay: technical and economic production optimizing calculations, or forecasts, for the following day, of the total required output and the procedure necessary for supplying this at the lowest cost; - in real time: on the basis of the forecasts for the previous day, creating the production instructions for the boiler houses and the instructions for the network remote control elements; - in case of an unexpected occurrence: immediate creation of new operating forecasts for the boiler houses for the establishing management data in real time. For the ...
1991-10-01
Generalized simulation model for reservoir system analysis. Technical paper
Energy Technology Data Exchange (ETDEWEB)
This paper overviews the general features of computer program 'HEC-5, Simulation of Flood Control and Conservation Systems', with emphasis on the capabilities of the most recent release of HEC-5, Version 7.2, dated March 1991. HEC-5 can simulate the essential features and operation goals and constraints of simple or complex systems with simulation intervals ranging from minutes to one month. Single event flood analysis and period of record conservation analysis may be accomplished with the model. Flood control analysis includes balanced system operation for downstream damage centers with consideration of forecasted local flows and hydrologic routing. In addition, induced surcharge operation based on spillway gate regulation schedules can be simulated. Hydropower analysis may include run-of-river, peaking, and pumped storage plants as well as system power operation. Water supply simulation can include reservoir and downstream ...
1992-03-01
Emergency reactor core cooling device
International Nuclear Information System (INIS)
The device of the present invention improves reactor safety by suppressing lowering of water level in a shroud which surrounds a reactor core, even upon occurrence of rupture of pipelines in an emergency reactor core cooling system in a recycling pump-incorporated type reactor. Namely, an opening of each of cooling systems which forms the emergency reactor core cooling device in a reactor pressure vessel is disposed above the upper end of the reactor core. Further, it also comprises an independent high pressure water injection system, gravitational dropping type water injection system and an automatic depressurization system. With such a constitution, even if rupture of pipelines in the system should be assumed, coolants never flow directly from the shroud which surrounds the reactor core. In addition, there are no pipelines to be ruptured below the upper end of the reactor core with respect to the ...
1993-03-16
Energy Technology Data Exchange (ETDEWEB)
A method and an instrument for determining the total water content in a hydrocarbon fuel using an indicator composition, which includes calcium hydride and phenolphthaleyn, are developed. The essence of the method is fixing the presence of water with its interaction with the calcium hydride and subsequent indication of the formed Ca(OH)2 using the phenolphthallen. To make the indicator composition, a hygroscopic cotton, prewashed by rectified alcohol and dried for 30 minutes at 105 degrees, is impregnated by a 1 percent alcohol solution of phenolphthaleyn and is dried in the same conditions. Then the cotton is processed by a powder form calcium hydride (a layer thickness of 0.1 to 0.2 millimeters, and a granule size of less than or equal to 80 micromters). The indicator composition is placed in a glass tube (a diameter of 4 to 7 millimeters and a length of 80 to 100 millimeters), whose ends are sealed or filled with paraffin. The content of ...
1983-01-01
Kootenai River Nutrient Dosing System and N-P Consumption: Year 2008.
In early 2006 we designed and built low energy consumption, pump-operated system, for dosing of the liquid nutrient in the summer 2006 season. This operated successfully, and the system was used again during the 2007 and 2008 seasons for dosing. During the early winter period, 2008, laboratory tests were made of the liquid nutrient pump system, and it was noted that small amounts of air were being entrained on the suction side of the pump, during conditions when the inlet pressure was low. It was believed that this was the cause of diurnal fluctuations in the flow supplied, characteristic of the 2007 year flow data. Replacement of '0' rings on the inlet side of the pumps was the solution to this problem, and when tested in the field during the summer season, the flow supplied was found to be stable. A decision was made by the IKERT committee at the meeting of 20th to 21st May 2008 ...
2009-02-19
Energy Technology Data Exchange (ETDEWEB)
Beside sucker-rod-type pumps and submersible centrifugal pumps, excentric screw pumps (so-called progressing cavity pumps) belong to standard conveyors in the production of crude oil. The authors of the contribution under consideration present the further development of excentric screw pumps with respect to the reduction of fluid levels in gas wells. This further development is based on a co-operation between the operator (Rohoel Aufsuchungs AG (Gampern, Austria)), the pump supplier (NETZSCH Oilfield Products GmbH (Selb, Federal Republic of Germany)) and the Institute for Process Technologies and Machinery at the University of Erlangen-Nuernberg (Federal Republic of Germany). The authors report on first attempts with the excentric screw pump at Weizberg (Federal Republic of Germany), material investigations at the University of ...
2008-10-23
Thermally conductive cementitious grouts for geothermal heat pumps. Progress report FY 1998
Energy Technology Data Exchange (ETDEWEB)
Research commenced in FY 97 to determine the suitability of superplasticized cement-sand grouts for backfilling vertical boreholes used with geothermal heat pump (GHP) systems. The overall objectives were to develop, evaluate and demonstrate cementitious grouts that could reduce the required bore length and improve the performance of GHPs. This report summarizes the accomplishments in FY 98. The developed thermally conductive grout consists of cement, water, a particular grade of silica sand, superplasticizer and a small amount of bentonite. While the primary function of the grout is to facilitate heat transfer between the U-loop and surrounding formation, it is also essential that the grout act as an effective borehole sealant. Two types of permeability (hydraulic conductivity) tests was conducted to evaluate the sealing performance of the cement-sand grout. Additional properties of the proposed grout that were investigated include bleeding, ...
1998-11-01
International water power and dam construction handbook
Energy Technology Data Exchange (ETDEWEB)
The first section of this Handbook describes hydro-electric projects currently under construction or recently commissioned in a number of countries. The major part of the Handbook is devoted to lists of data relating to hydro-electric plants and hydromachinery. These include: data for 1990 submitted by national power authorities on hydro-electric and pumped-storage plants in operation, under construction or planned; more detailed data for pumped-storage plants; country by country data on the dimensions, and reservoir and electrical capacity of major dams and hydro plant; a listing of roller compacted concrete dams; a listing of the world's largest turbines giving data on the largest unit at each scheme in rank order ranging from a unit capacity of 838 MV down to 147 MV; a similar list of the largest hydrogenerators ranging from a unit capacity of 825 MVA down to 150 MVA; details of turbine and generator contracts. The handbook ...
1992-01-01
Development of engineering technology basis for industrialization of pyrometallurgical reprocessing
International Nuclear Information System (INIS)
Development of the engineering technology basis of pyrometallurgical reprocessing is a key issue for industrialization. For development of the transport technologies of molten salt and liquid cadmium at around 500 deg. C, a salt transport test rig and a metal transport test rig were installed in Ar glove box. Function of centrifugal pump and 1/2'' declined tubing were confirmed with LiCl- KCl molten salt. The transport behavior of molten salt was found to follow that of water. Function of centrifugal pump, vacuum sucking and 1/2'' declined tubing were confirmed with liquid Cd. With employing the transport technologies, industrialization applicable electro-refiner was newly designed and engineering-scale model was fabricated in Ar glove box. The electro-refiner has semi-continuous liquid Cd cathode instead of conventional one used in small-scale tests. With using actinide-simulating elements, demonstration of ...
2007-09-09
British Library Electronic Table of Contents (United Kingdom)
Aim/hypothesis We examined whether the renin inhibitor, aliskiren, provides similar or greater protection than ACE inhibition from non-proliferative diabetic retinopathy and from the proliferative neoangiogenesis of oxygen-induced retinopathy. Methods Transgenic (mRen-2)27 rats, which overexpress mouse renin and angiotensin in extra-renal tissues, were studied. For diabetic studies, non-diabetic, diabetic (streptozotocin, 55?mg/kg), diabetic + aliskiren (10?mg?kg?1?day?1, pump), or diabetic + lisinopril (10?mg?kg?1?day?1, drinking water) rats were evaluated over 16?weeks. For oxygen-induced retinopathy studies, rats were exposed to 80% oxygen (22?h/day) from postnatal days?0 to 11, and then room air from postnatal days?12 to 18. Aliskiren (10 or 30?mg?kg?1?day?1, pump) or lisinopril (10?mg...
2011-01-01
Abrasive waterjet machining characteristics of aluminum matrix composites
Energy Technology Data Exchange (ETDEWEB)
Aluminum matrix composite Al356/SiCp(Vol. 15%)(Al MMC) material has been cut under various cutting conditions using Abrasive WaterJet (AWJ) machining process. The experimental cutting was carried out using three different material thicknesses of 10, 20, 30mm with a 0.33mm diameter orifice. The pump pressure, traverse rate, StandOff Distance(SOD) were taken as process parameters. After cutting the quality of the specimen in terms of kerf width, kerf taper, and surface finish were measured to characterize machinability of the material. As a result of the study, the maximum traverse rate for 30mm thick Al MMC under the pump pressure of 350 MPa reached up to 70 mm/min and the surface roughness of the material showed surface finish Ra in the range of 2.3{approx}23.4{mu}m.
2009-07-01
Energy Technology Data Exchange (ETDEWEB)
The Petroleum Technology Transfer Council (PTTC) and cooperating Regional Lead Organizations (RLOs) in its South Midcontinent (Oklahoma Geological Survey, Norman, Oklahoma) and West Coast (University of Southern California, Los Angeles, California) regions conducted a ''Mentor-Based Effort to Advance Implementation of Preferred Management Practices (PMPs) For Oil Producers'' (DE-FC26-01BC15272) under an award in Phase I of Department of Energy's (DOE's) PUMP (Preferred Upstream Management Practices) program. The project's objective was to enable producers in California, Oklahoma and Arkansas to increase oil production, moderating or potentially reversing production declines and extending the life of marginal wells in the near term. PTTC identified the primary constraints inhibiting oil production through surveys and PUMPer direct contacts in both regions. The leading common constraint was excess ...
2004-12-01
Finalisation of design provision for active process water system shut down at TAPP-3 and 4
International Nuclear Information System (INIS)
Active Process Water (APW) system is provided as a unitized system in TAPP-3 and 4. Maintenance on APW system requires shutdown of this system. As shut down heat exchangers are fed by APW system; during APW system shutdown cold shutdown state cannot be maintained. Therefore safety analysis is done to optimize the duration of reactor shutdown (which means low decay heat) after which APW shutdown can be taken with minimum water supply to the shutdown heat exchangers. Based on this analysis, it is proposed in technical specification that APW system shutdown can be taken after 7 days of reactor shutdown with shutdown heat exchangers supplied with about 20 % of normal APW flow. With this configuration, PHTS, moderator, end shield, calandria vault water temperature can be maintained within limits. A design provision is made at TAPP-3 and 4 to interconnect APW system of both units in such a way that one unit in addition to its own ...
2006-11-13
Cooling of nuclear power stations with high temperature reactors and helium turbine cycles
International Nuclear Information System (INIS)
On nuclear power stations with high temperature reactors and helium turbine cycles (HTR-single circuits) the residual heat from the energy conversion process in the primary and intermediate coolers is removed from cycled gas, helium. Water, which is circulated for safety reasons through a closed circuit, is used for cooling. The primary and intermediate coolers as well as other cooling equipment of the power plant are installed within the reactor building. The heat from the helium turbine cycle is removed to the environment most effectively by natural draught cooling towers. In this way a net plant efficiency of about 40% is attainable. The low quantities of residual heat thereby produced and the high (in comparison with power stations with steam turbine cycles) cooling agent pressure and cooling water reheat pressure in the circulating coolers enable an economically favourable design of the overall ...
High-tech hydro: an overview of pumped storage
A growing number of pumped storage plants installed within the US brings attention to the increasing significance of pumped storage as a source of electrical generation capacity. Because of the special benefits this technology has to offer, hydroelectric pumped storage is an option that many utilities should consider for the supply of new capacity requirements. This article surveys the development and use of pumped storage in the US, and considers the potential for the future development of this technology. Although some of the problems that have occurred on recent projects highlight the role of pumped storage as a technological proving ground, the article puts forth the view that pumped storage is maturing to play a significant role in US electricity supply.
Energy Technology Data Exchange (ETDEWEB)
With regard to a fracture system in the Hijiori hot dry rock artificial reservoir, an attempt was made on an interpretation which integrates different data. Major factors that characterize development and performance of an artificial reservoir are composed of a fracture system in rocks, which acts as circulating water paths, a heat exchange face and a reservoir space. The system relates not only with crack density distribution, but also with cracks activated by water pressure fracturing, cracks generating acoustic emission (AE), and cracks working as major flow paths, all of which are characterized by having respective behaviors and roles. Characteristics are shown on AE cluster distribution, crack distribution, production zone and estimated stress fields. Mutual relationship among these elements was discussed based on the Coulomb`s theory. The most important paths are characterized by distribution of slippery cracks. ...
1997-05-27
Heavy water reactor facility large-scale containment cooling test program
The Heavy Water Reactor Facility (HWRF), as part of the defense-in-depth philosophy to mitigate the effect of design-basis and severe accidents, is equipped with a passive containment cooling system (PCCS). The function of the PCCS is to provide a safety-grade path to the ultimate heat sink for the removal of the reactor coolant system sensible heat and core decay heat. Ambient air enters an annular space between the steel containment shell and the surrounding concrete shield building through inlets in the shield building wall, is heated via natural convection, rises, and exits the building through a chimney located above the containment dome. A test program is in place to access parameters important to the effective operation of the PCCS. This paper focuses on the large-scale tests (LSTs). The objectives of these tests are as follows: (1) demonstrate natural circulation cooling with more prototypic cylinder and dome surface area ratios than ...
1992-01-01
Heavy water reactor facility large-scale containment cooling test program
International Nuclear Information System (INIS)
The Heavy Water Reactor Facility (HWRF), as part of the defense-in-depth philosophy to mitigate the effect of design-basis and severe accidents, is equipped with a passive containment cooling system (PCCS). The function of the PCCS is to provide a safety-grade path to the ultimate heat sink for the removal of the reactor coolant system sensible heat and core decay heat. Ambient air enters an annular space between the steel containment shell and the surrounding concrete shield building through inlets in the shield building wall, is heated via natural convection, rises, and exits the building through a chimney located above the containment dome. A test program is in place to access parameters important to the effective operation of the PCCS. This paper focuses on the large-scale tests (LSTs). The objectives of these tests are as follows: (1) demonstrate natural circulation cooling with more prototypic cylinder and dome surface area ratios than ...
1992-11-15
Boiler and HRSG tube failures. Lesson 2. Corrosion fatigue
Energy Technology Data Exchange (ETDEWEB)
Fatigue damage occurs in general when a boiler tube is subject to repeat cyclic or fluctuating loading although the stress produced is below the material yield strength. The types of fatigue damage include, e.g., corrosion, thermal, mechanical, vibration, and creep fatigue. It is important to determine which form of fatigue is active, because measures to avoid repeat failures differ as the case arises. In this lesson, the focus is exclusively on corrosion fatigue. Corrosion fatigue occurs by the combined synergistic actions of cyclic loading and a corrosive environment. It is a discontinuous process with crack initiation and growth during transient periods. The excessive stresses may be caused during boiler operation by the restraint at tube attachments and by load changes (in particular during cold starts or forced cools) or during shutdown or restart of circulation boilers by thermal stratification of water along the tube length. Poor ...
2009-10-15
Energy Technology Data Exchange (ETDEWEB)
In order to gain a wider knowledge of corrosion phenomena in OFHC (oxygen free high conductivity) copper pipes of the stator cooling circuit of a power plant turboalternator, a research program was laid out which is based on the use of an experimental loop simulating real operating conditions as closely as possible. The samples examined were either copper foils or hollow conductors of the type that is normally used in the stator cooling system, and the circulating fluid was high purity water with controlled O/sub 2/, H/sub 2/ and C0/sub 2/ contents. Investigations were focused on the kinetics of O/sub 2/ removal through catalytic resins covered with metallic palladium (at different temperatures and pressures) and on the kinetics of CO/sub 2/ removal through mixed bed resins. Subsequently, attention was directed to the corrosion of copper (in the form of foils or hollow conductors) under different experimental conditions simulating either ...
1991-12-31
Energy Technology Data Exchange (ETDEWEB)
In France, groundwater usage represents 40 per cent of volumetric use, outside of thermal power plants. Groundwater represents 60 per cent of domestic and public use, 40 per cent in the industrial sector, and is increasing in the agricultural sector where it accounts for 20 per cent. Groundwater withdrawal in France has slightly increased over the last twenty years and benefited the agricultural sector. Availability throughout the territory, the consistency of resupply and natural quality has rendered groundwater a prevailing source for drinking water. Water protection and management is important and led to the adoption of legislative and regulatory measures. The Mining Code (Code minier) allows for exploitation of underground resources starting at 10 metres. The Rural Code (Code rural) mandates the declaration of public utility for water collection for the public. Protection areas are to be provided under the Public Health ...
2001-07-01
Verification of the CFD code FLUENT by post test calculation of ROCOM experiments
International Nuclear Information System (INIS)
Full text of publication follows: The TUV NORD e.V. is an independent Technical Support Organisation (TSO) performing safety assessments in almost every field of technology. In nuclear safety the TUV can look back on more than 40 years of experience. In the last years in Germany PWR safety analyses were focussed on boron dilution events with the potential of reactivity transients. The possibility of coolant with a low boron concentration collected in localized areas of the reactor coolant system (RCS) can be caused by injection of coolant with less boron content from interfacing systems (external dilution) as well as separation of borated reactor coolant into highly concentrated and diluted fractions (inherent dilution). Inherent dilution can e.g. occur after reflux-condenser heat transfer after a small break loss of coolant accident (SBLOCA) with a limited operability of the emergency core cooling (ECC) systems. The TUV Nord e.V. was charged by German supervisory authorities with the ...
2005-10-02
In the Loop : A look at Manitoba's geothermal heat pump industry
International Nuclear Information System (INIS)
This booklet outlines the position of Manitoba's heat pump market with the objective of promoting the widespread use of geothermal heat pumps in the province. It makes reference to the size of the market, customer satisfaction with heat pumps, and opinion of key players in the industry regarding the heat pump market. The information in this booklet is drawn on market research and lessons learned in Europe and the United States. In October 2001, a group of key stakeholders in Manitoba's heat pump market attended an industry working meeting to address the issues of market barriers, market enablers and market hot buttons. Market barriers include the high cost of geothermal heat pumps, lack of consumer awareness, lack of consistent standards, and public perception that heat pumps are not reliable. Market enablers include the low and stable ...
Vacuum system pump down analysis
Energy Technology Data Exchange (ETDEWEB)
My assignment on the SP-100 Vacuum Vessel Vacuum System Team was to perform a transient pump down analysis for the vacuum vessel that will house the SP-100 reactor during testing. Pump down time was calculated for air and helium. For all cases the proposed vacuum system will be able to pump down the vessel within the required time. The use of a larger rotary piston pump (DUO250) improves the pump down time by 35 minutes and therefore should be considered. The 6-inch duct for the roughing line is optimal, however, because all cases are well below the 24 hour time frame, the 4-inch duct is sufficient. The use of the single turbomolecular pump during pump down is sufficient. A pump down with helium in the vessel and a helium inleakage delays the time to achieve the base pressure marginally and is acceptable.
1990-08-01
Energy Technology Data Exchange (ETDEWEB)
Slurry characteristics have a significant impact on centrifugal pump performance. For instance, as particle size increases or the percent solids concentration increases, pump head and efficiency decrease. Therefore, before a slurry pump is selected, it is important to define the slurry characteristics as accurately as possible. The effect of the slurry characteristics on the head and efficiency of the centrifugal pump will be emphasized (the effect on flowrate is less significant). The effect of slurry characteristics is more predominant in smaller pumps (with smaller diameter impellers) than in larger pumps. The data and relationship between the various slurry parameters have been developed from correlations and nomographs published by pump vendors from their field data and test results. The information helps to avoid specifying an ...
1996-11-01
Method for processing statistical information concerning sucker-rod pump unit operations
Energy Technology Data Exchange (ETDEWEB)
The authors propose an integrated indicator of pump-rod couplings that allows both the couplings and the pump operations to be appraised according to the given formula. (Formula provided). The dynamic relationships of rod operations were determined with nomographs. These relationships involve such factors as: the type and size of the sucker-rod string; the pressure load at the equalizer head and its correlation to threshold pressure at pump discharge; pump diameter; the rod weight and construction; and integral reliability indicators.
1982-01-01
Water in chalk reservoirs: 'friend or foe?'
International Nuclear Information System (INIS)
Most of the petroleum fields in the Norwegian sector of the North Sea are sandstone reservoirs; the oil and gas are trapped in different species of sandstone. But the Ekofisk Field is a chalk reservoir, which really challenges the operator companies. When oil is produced from chalk reservoirs, water usually gets in and the reservoir subsides. The subsidence may be expensive for the oil companies or be used to advantage by increasing the recovery rate. Since 60 per cent of the world's petroleum reserves are located in carbonate reservoirs, it is important to understand what happens as oil and gas are pumped out. Comprehensive studies at the Department of Petroleum Technology and Applied Geophysics at Stavanger University College in Norway show that the mechanical properties of chalk are considerably altered when the pores in the rock become saturated with oil/gas or water under different stress conditions. The processes are ...
Energy Technology Data Exchange (ETDEWEB)
The adaption of the Muster-VAwS (model ordinance on the handling of water endangering substances in plants and specialized facilities) in the ordinances of the different German states, means that the legislator has laid down concrete - technical and organizational - requirements concerning the handling of water-endangering substances for all plants. The present example of the systematic stocktaking of all environmentally relevant substances in the context of the operation of the pumped storage plants of Schluchseewerk AG, Freiburg, an the application of the model operating instructions for hydropower plants shall serve to illustrate two important aspects for the implementation of this extensive ordinance. (orig.) [Deutsch] Durch Umsetzung der Muster-VAwS (Muster-Verordnung ueber Anlagen zum Umgang mit wassergefaehrdenden Stoffen und Fachbetriebe) in entsprechende Laenderverordnungen wurden durch den Gesetzgeber konkrete ...
1998-08-01
Economic analysis for utilization of geothermal energy by North Dakota Concrete Products Co.
Energy Technology Data Exchange (ETDEWEB)
North Dakota Concrete Products Company uses a steam curing process that accelerates the concrete curing so that 28-day strength is obtained within 24 hours. The cost of energy required to accomplish this is significant, amounting to approximately $80,000 in 1980. The present boilers are oil fired. Recently, fuel oil prices have increased substantially. Further, supply shortages in the past have threatened plant production. The purpose of this study was to evaluate the economic feasibility of using deep formation warm water as an alternative energy source. A water-to-water heat pump system to replace the existing boiler system was investigated. TPI, Inc. economic and engineering findings for this particular potential geothermal application are disclosed. The operating cost savings of the geothermal system over the operating costs of the existing oilfired system would be insufficient to provide an acceptable rate of return on ...
1982-02-01
Energy Technology Data Exchange (ETDEWEB)
This article gives an account of the recent development of light water reactors new concepts in the world. Different projects are being studied. The CE80+ from Combustion Engineering (CE) is a 1350 MWe-PWR-type reactor whose primary circuit is confined in a spherical metallic containment. This reactor was certified by NRC (national regulatory commission) in mid-1996. The APWR (advanced pressurized water reactor) is developed by MHI (Mitsubishi heavy industries) in a collaboration with Westinghouse, this PWR-type reactor fitted with 4 loops derived from the SP90 model that was developed by Westinghouse during the eighties. 2 units of ABWR (advanced boiling water reactor) were commissioned in Japan in 1996 and 1997, ABWR was certified by NRC in mid-1996. The BWR90+ is developed by ABB-atom (Sweden) and it represents a cautious advanced version of the BWR75. Passive reactors are reactors that rely only on potential energy ...
2001-07-01
Guideline for Sampling and Analysis of Tar and Particles in Biomass Producer Gases. Version 3.3
Energy Technology Data Exchange (ETDEWEB)
This Guideline provides a set of procedures for the measurement of organic contaminants and particles in producer gases from biomass gasifiers. The procedures are designed to cover different gasifier types (updraft or downdraft fixed bed or fluidised bed gasifiers), operating conditions (0 - 900C and 0.6-60 bars) and concentration ranges (1 mg/m{sub n}{sup 3} to 300 g/m{sub n}{sup 3}). The Guideline describes a modular sampling train, and a set of procedures, which include: planning and preparation of the sampling, sampling and post-sampling, analysis, calculations, error analysis and reporting. The modular sampling train consists of 4 modules. Module 1 is a preconditioning module for isokinetic sampling and gas cooling. Module 2 is a particle collection module including a heated filter. Module 3 is a tar collection module with a gas quench (optionally by circulating a liquid), impinger bottles and a backup adsorber. Module 4 is a volume-sampling module consisting ...
2002-07-01
Best of the lot : engineered measurement-while-drilling tool improves efficiency of operations
Energy Technology Data Exchange (ETDEWEB)
NuEra Oilfield Services Inc. combines various technologies, including advanced bearing assemblies and compact wireless decoders that interface with downhole directional tools, to engineer unique, purpose-built measurement-while-drilling (MWD) tool string packages. The 9-metre-long MWD tool string is lowered into the drill pipe from the surface. The directional module monitors the position of the drill bit, which the driller can monitor using an electronic drilling recorder at the surface. The directional drillstring uses a mud motor with adjustable bent housing to correct the direction of the well, as the system cannot steer while drilling. At bottomhole, mud circulation continues after the rotation of the drillstring has been stopped, driving the mud motor, which in turn drives the drill bit, permitting a new direction to be taken even though the drillstring is not turning. The operator points the bent housing in a new direction and slides the bit along before ...
2010-10-15
Energy Technology Data Exchange (ETDEWEB)
Two refrains heard in the current retail wheeling debate are that a restructuring of the electric utility industry is inevitable and that its consequences are unpredictable. Notwithstanding the benefits of open competition, there are specific disadvantages of unlimited retail wheeling for some existing independent facilities and especially for hydropower plants. A capital-intensive industry, hydropower is not well-postured to compete effectively in the short-term, against new technologies and fuel sources available in the current marketplace. Hydropower is flat out non-competitive on a price basis with available new capacity. Unless hydro is afforded the same government supports offered to other renewable energy sources, only municipal plants with access to subsidized financing rates and pumped storage plants are going to be built.
1995-03-01
TREATMENT OF RADIOACTIVE EFFLUENTS AT THE MOL LABORATORIES
The cold effluents (sanitary waste and decontaminated radioactive water) are flocculated with sodium phosphate and pumped through a trickling filter. The average decontamination obtained is about 86% for alpha emittera and 76% for beta emitters. The cool effluents (activity < 10/sup -3/ mu c/ml) can be treated by several methods. Provisions have been made for two successive chemical flocculations eventually followed by an adsorptlon. The warm waste treatment (activity between 10/sup -3/ and 1 mu c/ml) is still in the experimental stage. The following methods are used: evaporation for some chemically contaminated wastes, browncoal filtration for reactor effluents, and a combination of chemical treatment and browncoal adsorption in other cases. (auth)
1959-10-31
Silver removal process development for the MEO cleanout
Energy Technology Data Exchange (ETDEWEB)
The Mediated Electrochemical Oxidation (MEO) system is an aqueous process which treats low-level mixed wastes by oxidizing the organic components of he waste into carbon dioxide and water. As MEO system continues to run, dissolved ash and radionuclides slowly accumulate in the anolyte and must be removed to maintain process efficiency. At such time, all of the anolyte is pumped into a still feed tank, and the silver ions need to be removed before sending the solution to a thin-film evaporator for further concentration. The efficiency of removing silver ions in the solution needs to be high enough such that the residual silver sent to Final Forms would be less than 1% wt. The purpose of this work is to develop an efficient process to remove silver ions during the MEO cleanout and to demonstrate the capability of centrifugation for separating small silver chloride particles from the solution. This development work includes lab scale experiments ...
1996-02-01
Prospects of wind energy in Bangladesh
Energy Technology Data Exchange (ETDEWEB)
Wind speed has been measured in Patenga, Cox`s Bazar, Kuakata, Moheshkhali, and Noakhali by the computerized anemometers. The wind computers have been installed at 20 meters height. According to this study annual average wind speeds in the coastal regions of Bangladesh are greater than 6.5 m/s at the height of 20 meters. It has been observed that during day times (8 a.m. to 7 p.m.) wind speeds are about 30 to 40% higher than the average values. The value of the power exponent {alpha} has been determined in the above sites and it is 0.139. So, at 40 meters height the annual average wind speed is about 7.15 m/s. So, wind speeds in the coastal regions of Bangladesh are suitable for both water pumping and electricity generation. Details are given in this paper with graphical and analytical representations. (author)
1996-09-01
Means and method of balancing multi-cylinder reciprocating machines
Energy Technology Data Exchange (ETDEWEB)
A virtual balancing axis arrangement is described for multi-cylinder reciprocating piston machines for effectively balancing out imbalanced forces and minimizing residual imbalance moments acting on the crankshaft of such machines without requiring the use of additional parallel-arrayed balancing shafts or complex and expensive gear arrangements. The novel virtual balancing axis arrangement is capable of being designed into multi-cylinder reciprocating piston and crankshaft machines for substantially reducing vibrations induced during operation of such machines with only minimal number of additional component parts. Some of the required component parts may be available from parts already required for operation of auxiliary equipment, such as oil and water pumps used in certain types of reciprocating piston and crankshaft machine so that by appropriate location and dimensioning in accordance with the teachings of the invention, the virtual ...
1985-01-01
Energy Technology Data Exchange (ETDEWEB)
Visits were made to selected manufacturing units with 25 or more employees. Information was gathered on energy consumption and advice was given on the opportunities available for improving the efficiency of energy use. Potential energy savings are estimated and recommendations are made on the action that should be taken to improve the efficiency of energy use. In the footwear industry space heating controls, improvements in boiler plant and steam services along with building insulation provide most of the savings potential. In the leather industries major energy saving opportunities can be found in low-temperature drying, and heat recovery, where the use of heat pumps could contribute substantial savings in drying and process water heating. Boiler controls and good housekeeping are areas where firms can make worthwhile savings at very little capital cost. (MCW)
1980-11-01
Development of sealing insulator for electric penetration assemblies
International Nuclear Information System (INIS)
Electrical penetration assemblies mounted on the containment wall are used to carry electrical power and signals from the equipment inside this containment (e.g. recirculation pumps, control rod position indications etc.) Todays BWR nuclear power plants apply epoxy resin sealed electric penetration. Contrariwise, the epoxy resin (organic sealant) was replaced with sodium barium glass (inorganic) by way of trial in search for a quality sealant. The glass sealant has been proved to have high temperature airtightness at 300 degC above from an evaluation test involving full-scale model parts. Environmental tests were conducted continuously as to heat cycle, vibration and LOCA etc. the specimens (module) of five types. They were made certain of conformity to the design requirements for boiling water operation. (author).
Comparative study in supplying electrical energy to small remote loads in Libya
Energy Technology Data Exchange (ETDEWEB)
The main sources of energy that might be available in remote low populated areas of Libya are either diesel generating units or wind mills for water pumping. Several problems in the working performance of these two types of energy production may arise due to environmental conditions. Direct conversion of solar energy can replace other ways of energy delivery or production, especially in this country where the solar radiation all year is relatively high. Direct conversion of solar energy is relatively expensive, however the cost of erecting long feeders and supervising them may be much more expensive than the usage of solar systems. This paper investigates the economics associated with either solutions of energy production. A case study is given in detail to supply one of the remote areas with a population of about 250. (author)
1998-05-01
Hydrologic Tests at Characterization Wells R-9i, R-13, R-19, R-22, and R-31
Energy Technology Data Exchange (ETDEWEB)
Hydrologic information is essential for environmental efforts at Los Alamos National Laboratory. Testing at new characterization wells being drilled to the regional aquifer (''R wells'') to improve the conceptual hydrogeologic model of the Pajarito Plateau is providing such information. Drilling has been by air-rotary casing-advance or open-hole methods. Most wells are completed with multiple screens. After their construction, wells were rigorously developed by wire-brushing, bailing, followed by surging, swabbing, or jetting, and finally by pumping. These methods are effective based on field-parameter measurements and comparison of results of hydrologic testing at well R-31 before and after complete well development. We conducted field tests on various zones of saturation penetrated by the R wells to collect data needed for determining hydraulic properties. This document provides details of the design and execution of testing as ...
2003-03-01
The role of natural circulation in the FFTF [Fast Flux Test Facility] passive safety tests
International Nuclear Information System (INIS)
A series of tests were completed at the Fast Flux Test Facility to demonstrate the passive safety characteristics of liquid metal reactors with natural circulation flow. The first test consisted of transition from forced to natural circulation flow at an initial decay power of 0.3%. The second test represented an unprotected loss-of-flow transient to natural circulation from 50% power with the control rods prevented from scramming into the core. The third test was a steady-state, natural circulation condition with core fission powers up ato about 2.3%. Core sodium data and results of single and multi-channel computer models confirmed the reliability and effectiveness of natural circulation flow for liquid metal reactor safety.
1987-12-13
Selecting the right pumps and valves for flue gas desulfurization
Limestone slurry needs to move efficiently through a complex process, meaning that selecting the right pumps and valves is critical. The article discusses factors to consider in selecting pumps and values for flue gas desulfurization process in coal-fired power plants. 2 photos.
2006-07-15
EDF's experience in the operation of pump-storage plants
Energy Technology Data Exchange (ETDEWEB)
This paper describes the advent of energy pumped storage plants in France, in connection with nuclear power reactors development and gives detailed specifications of different components (pump turbines, alternators, valves ...). 5 figs., 3 tabs.
1992-01-01
A method for acetic processing of an electric, centrifugal well pump
Energy Technology Data Exchange (ETDEWEB)
In order to reduce the length and to increase the effectiveness of processing, the proposed method for acetic processing of an electric centrifugal well pump calls for covering the pressure line during the curing and periodically starting the pump.
1983-01-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of the chapter is to explain briefly the various considerations that enter into determining the general layout or arrangement of typical hydroelectric powerplants, pumping plants, and pumped-storage plants. Some of the important factors that affect or determine the location, type, and layout of the plant and the selection of the major items of equipment included in the installation are outlined in this chapter. The first consideration in the design of a powerplant, pumping plant, or pumped-storage plant is that it adequately perform its function and be structurally safe. The structure is also designed to give a pleasing architectural appearance.
1985-05-01
As a result of the large limestone deposits available in Poland, the low cost of reagent acquisition for the largescale technological use and relatively well-documented processes of flue gas desulfurization (FGD) technologies based on limestone sorbent slurry, wet scrubbing desulfurization is a method of choice in Poland for flue gas treatment in energy production facilities, including power plants and industrial systems. The efficiency of FGD using the above method depends on several technological and kinetic parameters, particularly on the pH value of the sorbent (i.e., ground limestone suspended in water). Consequently, many studies in Poland and abroad address the impact of various parameters on the pH value of the sorbent suspension, such as the average diameter of sorbent particles (related to the limestone pulverization degree), sorbent quality (in terms of pure calcium carbonate [CaCO3] content of the sorbent material), stoichiometric surfeit of CaCO3 in ...
2010-08-01
Underground reservoirs for high-head pumped-storage stations
The advantages of using heads of around 1000 m in conjunction with underground location of the lower reservoirs for pumped storage plants are described, and the possible layouts, equipment, and construction methods are discussed.
1973-03-01
CSCL 10B Unclas G3/03 29020 INFORMATION SERVICE - NASA Technical ...
pumped storage plants; but these must be built as well since there is no correspondence with the pump and turbine operating times governed by normal network ...
Energy Technology Data Exchange (ETDEWEB)
The core bypass phenomenon of borated water injected through direct vessel injection (DVI) nozzles in APR1400 (Advanced Power Reactor 1400MWe) during main steam line break (MSLB) accidents with a reactor coolant pump (RCP) running mode has been simulated using a two-channel and one-dimensional system analysis model code (MARS), and a three-dimensional computational fluid dynamics (CFD) code (FLUENT). A visualization experiment has also been performed using a scaled-down model of the APR1400. The MARS analysis has predicted a serious core bypass phenomenon of borated water, while the CFD analysis has shown results opposite to the MARS results. The CFD analysis has shown that the flow pattern in the downcomer is fully three-dimensional and that vortex flow structures are formed near the cold legs so that the borated water might pass without difficulty into the high flow region of the cold legs and flow ...
2007-04-15
JAMA Patient Page: Cardiopulmonary Resuscitation (CPR)
... of the American Medical Association JAMA PATIENT PAGE Cardiopulmonary Resuscitation W hen the heart stops beating (cardiac arrest), ... circulation (blood flow) returns or is restored. Providing cardiopulmonary resuscitation ( CPR ) is a way to keep some circulation ...
UK PubMed Central (United Kingdom)
PurposeThe aim of this investigation was to exploit lens-specific glycated crystallins as an immunogen to detect human glycated crystallins and their circulating autoantibodies in...Full Text Available
Coolant rate distribution in horizontal steam generator under natural circulation
Energy Technology Data Exchange (ETDEWEB)
In the presentation the major factors determining the conditions of NCC (Natural Coolant Circulation) in the primary circuit and in particular conditions of coolant rate distribution on the horizontal tubes of PGV-1000 in NPP with VVER-1000 under NCC are considered. 5 refs.
1997-12-31
International Nuclear Information System (INIS)
Liquid Zone Control (LZC) System is a 'first-of-its-kind' reactivity control device, designed and implemented at TAPP-3 and 4. The system provides zonal and bulk power control. The system consists of fourteen Zone Control Compartments (ZCCs) containing demineralised light water as neutron absorber. Reactivity control is achieved by varying the level of water in the compartments bi-directionally. Six in-core zircaloy assemblies, housing the fourteen ZCCs and an elaborate process system constitute the LZC system. Measurement of water levels in the ZCCs is done using helium bubbler method. Reliability of ZCC water level measurement is of paramount importance. Commissioning and operating the new system trouble free was a challenge, considering the complex nature of the system. While commissioning the system, level measurement of one of the ZCCs (ZCC - 1) was found erratic and inconsistent. Methodologies ...
2006-11-13
Engineering design of cryocondensation pumps for the DIII-D Radiative Divertor Program
Energy Technology Data Exchange (ETDEWEB)
A new double-null, slotted divertor configuration will be installed for the DIII-D Radiative Divertor Program at General Atomics in late 1996. Four cryocondensation pumps, three new and one existing, will be part of this new divertor. The purpose of the pumps is to provide plasma density control and to limit the impurities entering the plasma core by providing pumping at each divertor strike point. The three new pumps are based on the design of the existing pump, installed in 1992 as part of the Advanced Divertor Program. The pump continues to operate successfully. The new pumps require geometry modifications to the original design. Therefore, extensive modal and dynamic analyses were performed to determine the behavior of these pumps and their helium and nitrogen feed lines during disruption events. Thermal and fluid ...
1995-12-31
Engineering design of cryocondensation pumps for the DIII-D Radiative Divertor Program
International Nuclear Information System (INIS)
A new double-null, slotted divertor configuration will be installed for the DIII-D Radiative Divertor Program at General Atomics in late 1996. Four cryocondensation pumps, three new and one existing, will be part of this new divertor. The purpose of the pumps is to provide plasma density control and to limit the impurities entering the plasma core by providing pumping at each divertor strike point. The three new pumps are based on the design of the existing pump, installed in 1992 as part of the Advanced Divertor Program. The pump continues to operate successfully. The new pumps require geometry modifications to the original design. Therefore, extensive modal and dynamic analyses were performed to determine the behavior of these pumps and their helium and nitrogen feed lines during disruption events. Thermal and fluid ...
1995-10-01
Superconducting Switchable Circulator
... as time delay shifters for large-area phased arrays in military (MILSTAR) as well as commercial (Sky phone and other satellite communication) systems, ...
... Massage therapy can help the body release certain chemicals. These chemicals help us relax, improve blood circulation and get ...
Design and performance tests of flap value for HANARO natural circulation cooling
International Nuclear Information System (INIS)
... [2] Hee Taek Chae, et al., "On the Natural Convection Cooling in HANARO;
1999-09-06
Energy Technology Data Exchange (ETDEWEB)
Due to its important hydroelectric power generation facilities (about 525 plants with a total power of 13,314 MW producing about 35.3 TWh annually) Switzerland plays an important role in the interconnected European power system. Large artificial storage lakes in the Swiss Alps can generate peak power during hours of highest demand: 9700 MW are available from accumulated energy and the total power of pumped-storage facilities amounts to 1700 MW. The latter allow refilling the reservoirs at periods of low power demand and generating power at periods of peak demand. In the case of favorable conditions, the yearly average power production could be increased by 6% and the production during the winter period (October to March) by 20% by the year 2020. However, looking forward to the year 2050, the annual production is expected to decrease by 3% despite a possible extension of hydropower. This decrease is due to the enforcement of the minimum residual ...
2007-07-01
Natural circulation reactor design safety analysis
This thesis study covers both global performance and local phenomena analyses focusing on natural circulation reactor design safety. Four important topics are included: the global SBWR design safety assessment, important local phenomena investigation, steady and transient natural circulation process study, and two-phase instability analysis. The conceptual design of the SBWR-200 is introduced in this thesis and the global performance of a natural circulation reactor is then assessed using PUMA integral test data and RELAP5 simulations. A safety assessment methodology is developed to evaluate the PUMA integral test data extrapolation and code scalability. The RELAP5 code simulation capability in low-pressure low-flow conditions is also validated. The study shows that the code is capable of predicting the global accident scenario in natural circulation reactors with reasonable accuracy, while failing to ...
2001-01-01
Development of pressurized internally circulating fluidized-bed (PICFB) technology
Energy Technology Data Exchange (ETDEWEB)
After the completion of the 4MWth pilot plant of the Pressurizied Internally Circulating Fluidized-bed Boiler (PICFB), a total of 15 test runs, amounting to 2280 hours of operation, were concluded. The test results have confirmed the superior operating performance. Additionally, Ebara plans to develop a Pressurized Internally Circulating Fluidized-bed Gasifier (PICFG or Advanced PICFB). 8 figs.
1998-07-01
Potential for geothermal development in Southern Poland
Energy Technology Data Exchange (ETDEWEB)
This paper discusses the potential for geothermal energy use in the central part of Southern Poland, such as the availability of thermal aquifers and the techniques for putting the latter to practical use. The geological and geothermal features of the region are presented within the context of the existence of aquifers containing geothermal resources that could be used in space heating. Also discussed are the three main geological units where thermal waters are known to exist: the Carpathians, the Miechow Trough, and the Silesian-Cracow Monocline. Particularly favourable hydrogeological conditions exist in the Inner Carpathians, in the Podhale Trough, where there is already one geothermal company using geothermal energy, Geotermia Podhalanska S.A. Equally interesting from the geothermal point of view are the areas north of the Cracow-Tarnow line, where, in Mesozoic aquifers, water temperatures range from 20 to 60 {sup o}C. In this paper we ...
2004-06-01
Energy Technology Data Exchange (ETDEWEB)
This project of law concerns an additional protocol to the agreement of warranties signed on September 22, 1998 between France, the European atomic energy community and the IAEA. This agreement concerns the declaration of all information relative to the R and D activities linked with the fuel cycle and involving the cooperation with a foreign country non endowed with nuclear weapons. These information include the trade and processing of nuclear and non-nuclear materials and equipments devoted to nuclear reactors (pressure vessels, fuel loading/unloading systems, control rods, force and zirconium tubes, primary coolant pumps, deuterium and heavy water, nuclear-grade graphite), to fuel reprocessing plants, to isotope separation plants (gaseous diffusion, laser enrichment, plasma separation, electromagnetic enrichment), to heavy water and deuterium production plants, and to uranium conversion plants. (J.S.)
2002-10-01
Fifteenmile Basin habitat enhancement project : annual report FY 1990.; ANNUAL
International Nuclear Information System (INIS)
The goal of the Fifteenmile Creek Habitat Improvement project is to improve wild winter steelhead habitat in the Fifteenmile Creek Basin. This goal was addressed under the Columbia River Basin Fish and Wildlife Program, Measure 703 (c) (1) - Action Item 4.2. Construction of fish habitat structures was completed on approximately 3.5 miles of Eightmile Creek and on approximately 8.5 miles of Fifteenmile Creek. A total of 15,435 yds of rock was placed to improve rearing and spawning habitat, and to improve water quality and reduce siltation. Riparian protection fencing was completed on 1.8 miles of Dry Creek, approximately 1.75 miles on Eightmile Creek, and 4.75 miles on Fifteenmile Creek. Approximately 10 miles of stream will receive protection from the 8 miles of new fencing installed and 6.5 miles of abandoned fence repaired. Irrigation withdrawal screens were installed at six irrigation pump withdrawals. These screens functioned satisfactorily ...
Control of the reduction/oxidation potential of Hanford Waste Vitrification Plant feeds
International Nuclear Information System (INIS)
A schematic diagram shows the various processing steps to be performed during feed preparation in the Hanford Waste Vitrification Plant (HWVP). The pretreated NCAW is transferred to the slurry receipt adjustment tank (SRAT) in the HWVP for concentration. Water removed during boildown is collected in the slurry mix evaporator condensate tank (SMECT). After waste treatment the water is returned to the storage tanks for eventual disposal. The pretreated Neutralized Current Acid Waste (NCAW) is concentrated in the SRAT to approximately 125 g waste oxides/ liter. Formic acid is then added at a controlled rate to improve rheological properties and achieve a required reduction/oxidation state. Reflux boiling is initiated and continued for several hours. The concentrated slurry is cooled and pumped to the slurry mix evaporator (SME). In the SME, glass frit is added, and the slurry is further concentrated to achieve a nominal ...
1988-09-11
Centrifugal potential energy : an astounding renewable energy concept
Energy Technology Data Exchange (ETDEWEB)
A new energy concept known as centrifugal potential energy was discussed. This new energy concept is capable of increasing the pressure, temperature and enthalpy of a fluid, without having to apply work or heat transfer to the fluid. It occurs through a change in the centrifugal potential energy of the flowing fluid in a rotating frame of reference or a centrifugal force field, where work is performed internally by the centrifugal weight of the fluid. This energy concept has resulted in new energy equations, such as the Rotational Frame Bernoulli's Equation for liquids and the Rotational Frame Steady-Flow Energy Equation for gases. Applications of these equations have been incorporated into the design of centrifugal field pumps and compressors. Rather than compressing a fluid with a physical load transfer, these devices can compress a fluid via the effect of centrifugal force applied to the object. A large amount of energy is therefore produced when this ...
2010-07-01
Simulation of SBWR startup transient and stability
The Simplified Boiling Water Reactor (SBWR) designed by General Electric is a natural circulation reactor with enhanced safety features for potential accidents. It has a strong coupling between power and flow in the reactor core, hence the neutronic coupling with thermal-hydraulics is specially important. The potential geysering instability during the early part of a SBWR startup at low flow, low power and low pressure is of particular concern. The RAMONA-4B computer code developed at Brookhaven National Laboratory (BNL) for the SBWR has been used to simulate a SBWR startup transient and evaluate its stability, using a simplified four-channel representation of the reactor core for the thermal-hydraulics. This transient was run for 20,000 sec (5.56 hrs) in order to cover the essential aspect of the SBWR startup. The simulation showed that the SBWR startup was a very challenging event to analyze as it required accurate modeling of the ...
1998-06-01
Energy Technology Data Exchange (ETDEWEB)
The subfornical organ is a major receptor area for one of the principal stimuli of thirst, the octapeptide, angiotensin II. In conscious water-sated rats, the authors examined the effects of intravenous infusion of angiotensin II on the rate of glucose utilization in the subfornical organ and in structures anatomically and functionally connected with it. Angiotensin II produced pressor and drinking responses and increased glucose utilization selectively in the subfornical organ and pituitary neural lobe and in no other brain structure. Treatment with the angiotensin II antagonist, sar1-leu8-angiotensin II, before intravenous administration of angiotensin II prevented metabolic stimulation of the subfornical organ and neural lobe. Captopril, an inhibitor of angiotensin-converting enzyme, reduced subfornical organ glucose metabolism to a level similar to that found in control animals. These results demonstrate that peripheral angiotensin II stimulates glucose ...
1985-01-01
Measures for reliability improvement of on-site power plant at steel works
Energy Technology Data Exchange (ETDEWEB)
This report describes the arrangement and features of the Ogishima thermal power plant facilities, as well as activities being performed there for operation control, regular inspection and improvement in reliability. The power plant uses about 48 percent of the by-product gas as its fuel to supply about 81 percent of the required power. Operation of the No. 1 unit started in 1976. Currently, the plant has three units, each with an output of 125MW. Each unit consists of a natural circulation boiler with a maximum evaporation capacity of 410 ton/hour and a reheat regenerative condensing turbine with a main vapor pressure of 127 kg/cm/sup 2/G. Techniques used for water properties control and combustion control are also described. In the plant, convetional time management integrity techniques are now being replaced by state management integrity techniques that determines the deterioration tendency in separate sections of the facilities which are ...
1988-04-15
British Library Electronic Table of Contents (United Kingdom)
One method of increasing juvenile fish escapement from net cod-ends is to encourage fish to approach the netting by placing an active stimulating device (ASD) in the cod-end. Two types of ASD were tested inside model cod-ends to generate variable visual stimuli. One was a free-end flag-like net panel and the other consisted of an array of free-ended ropes. Escape responses of juvenile red seabream were observed in a circulating water channel using a cod-end fitted with the ASD, and they were compared with responses to conventional polyethylene multi-ply, high-contrast cod-ends with and without ASD made from either 28- or 43-mm mesh under three light conditions. With the ASD attached, the retention rate was significantly lower, 20%, than for conventional cod-ends except in dim light with 28...
2010-01-01
AP1000 plant construction in China: Ansaldo Nucleare contribution
International Nuclear Information System (INIS)
On 24th of July 2007 Westinghouse Electric Co. signed landmark contracts with China's State Nuclear Power Technology Corporation (SNPTC), to provide four AP1000 nuclear power plants in China. The AP1000 is a two-loop 1117 MWe Pressurized Water Reactor (PWR). It is based on proven technology, but with an emphasis on safety features that rely on natural driving forces, such as pressurized gas, gravity flow, natural circulation flow and convection. Ansaldo Nucleare has provided a significant support to the passive plant technology development and, starting from 2000, is cooperating with Westinghouse to development of the AP1000 Plant. In the frame of the AP1000 Chinese agreement, Ansaldo Nucleare, in Joint Venture with Mangiarotti Nuclear, has signed a contract with Westinghouse for the design and the supply of innovative components to be installed in the first AP1000 unit to be constructed at the Sanmen site. The contract includes: the design of ...
2009-10-12
Unsteady-state flow of methane and water in coal beds
Energy Technology Data Exchange (ETDEWEB)
A hypothesis on the transition of a fully water-saturated coal bed methane reservoir from single-phase flow through unsaturated flow to the two-phase flow regime was developed and substantiated using field data. The concept of parameter measurement windows was introduced to obtain the required reservoir parameters from flow testing. A new empirical relationship for capillary pressure vs. saturation, referred to as the Fermi distribution, was developed and shown to fit the capillary pressure-saturation data for coal, sandstone, and other consolidated and unconsolidated materials. New approximate analytic solutions for flow to a sink from an infinite coal bed reservoir with desorbing methane have been developed and verified using numerical models for the following cases: (1) single-phase gas flow with desorption; (2) single-phase water flow in fully water-saturated and unsaturated flow regimes. A numerical model based on ...
1987-01-01
Measurements of radon concentration levels in drinking water at urban area of Curitiba, Brazil
International Nuclear Information System (INIS)
Current work presents the results of more than 100 measurements of 222Rn activity in drinking water collected at artesian bores at Curitiba region during the period of 2008 - 2009. The measurements were performed at the Laboratory of Applied Nuclear Physics of the Federal University of Technology in cooperation with the Nuclear Technology Development Center (CDTN) of Brazilian Nuclear Energy Committee (CNEN). Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specific kit of glass vessels Aqua KIT through the air pump. The equipment was adjusted with air flow of 0.5 L/min. The 222Rn concentration levels were detected and analyzed by the computer every 10 minutes using the software DataEXPERT by GENITRON Instruments. Collected average levels of 222Rn concentration were processed taking into account the volume of water sample and its temperature, atmospheric pressure and the total volume ...
Physical modeling of flow control device test in intake structure
International Nuclear Information System (INIS)
The seawater in the intake structure flows into the large pump to with draw excess heat from the turbine steam condenser. In the intake structure of a nuclear power plant, undesirable pump operating characteristics such as vortices, impeller damages and non-uniform pump-approach flow around the pump bells take place frequently due to poorly-arranged intake geometry. In this study, physical modeling test was performed to predict the hydraulic phenomenon, and proposed flow control devices.
2000-05-01
Geothermal heat pumps - gaining ground in the UK and worldwide
Energy Technology Data Exchange (ETDEWEB)
This 2001 edition of the guide to UK renewable energy companies examines the geothermal heat pump sector, and discusses the technology involved, installations of geothermal heat pumps, the activity in the UK market with increased interest in UK geothermal heat pump products from abroad, and developments in the building sector. The UK government's increased support for the industry including its sponsorship of the Affordable Warmth programme, and the future potential of ground source systems are discussed.
2001-07-01
Geothermal heat pumps - gaining ground in the UK and worldwide
International Nuclear Information System (INIS)
This 2001 edition of the guide to UK renewable energy companies examines the geothermal heat pump sector, and discusses the technology involved, installations of geothermal heat pumps, the activity in the UK market with increased interest in UK geothermal heat pump products from abroad, and developments in the building sector. The UK government's increased support for the industry including its sponsorship of the Affordable Warmth programme, and the future potential of ground source systems are discussed.
Evaluating and improving the operating reliability of the units of sucker rod well pumps
Energy Technology Data Exchange (ETDEWEB)
The theory of reliability is used to develop statistical field data on malfunctions of units of sucker rod well pumps (UShSN). The indices of reliability of the UShSN are applied for establishment of the cause-effect links between the operating factors. Dependences of operating time on the depth of suspension of the pumps, mode of pumping out, degree of flooding of the oil, and twisting of the shafts are established for conditions of specific fields. The obtained relationships can be used in selecting and optimizing the work of the UShSN.
1982-01-01
International Nuclear Information System (INIS)
... bypasses control rod drives cylinders electromagnetic pumps fluid flow fluidic
Effect of a pumped storage plant on the generation reliability of the Taiwan power system
Energy Technology Data Exchange (ETDEWEB)
A novel approach to the reliability analysis of a power system with both hydro and pumped storage plants is presented in this paper. The proposed method is based on the concept of peak shaving for the hydro and pumped storage units. Different values of the stored energy of the pumped storage units are employed to demonstrate their effect on the generation reliability of a power system. The proposed scheme has been applied successfully to the reliability analysis of Taiwan power system.
1986-05-01
Energy Technology Data Exchange (ETDEWEB)
Experimental investigations have been conducted to determine two-phase natural circulation interfacial parameters by real-time neutron radiography. The natural circulation loop used in the present experiments consists of a vertical two-phase section, a gas liquid separator, and a gas injection/heating section. Experiments were performed in a neutron beam for visualization using realtime neutron radiography system. The natural circulation was initiated by injection of known gas flow rate in the heated section. Two-phase flow interfacial parameters including interfacial geometry and phase velocities etc. for bubbly flow and slug flow patterns observed in the experiments will be given in detail. The results indicate that while the natural circulation is largely as expected and that steady stable flows are possible, there are some local phenomena that introduce instabilities due to the interfacial phenomena ...
2003-07-01
International Nuclear Information System (INIS)
Experimental investigations have been conducted to determine two-phase natural circulation interfacial parameters by real-time neutron radiography. The natural circulation loop used in the present experiments consists of a vertical two-phase section, a gas liquid separator, and a gas injection/heating section. Experiments were performed in a neutron beam for visualization using realtime neutron radiography system. The natural circulation was initiated by injection of known gas flow rate in the heated section. Two-phase flow interfacial parameters including interfacial geometry and phase velocities etc. for bubbly flow and slug flow patterns observed in the experiments will be given in detail. The results indicate that while the natural circulation is largely as expected and that steady stable flows are possible, there are some local phenomena that introduce instabilities due to the interfacial phenomena ...
2003-10-05
Engineering design of cryocondensation pumps for the DIII-D Radiative Divertor Program
Energy Technology Data Exchange (ETDEWEB)
A new double-null, slotted divertor configuration will be installed for the DIII-D Radiative Divertor Program at General Atomics in late 1996. Four cryocondensation pumps, three new and one existing, will be part of this new divertor. The purpose of the pumps is to provide plasma density control and to limit the impurities entering the plasma core by providing pumping at each divertor strike point. The three new pumps are based on the design of the existing pump, installed in 1992 as part of the Advanced Divertor Program. The new pumps require geometry modifications to the original design. Therefore, extensive modal and dynamic analyses were performed to determine the behavior of these pumps and their helium and nitrogen feed lines during disruption events. Thermal and fluid analyses were also performed to characterize the helium two-phase ...
1995-10-01
Study on core cooling of hybrid safety system for next-generation PWR during LOCA
International Nuclear Information System (INIS)
Mitsubishi is now developing a next-generation Pressurized Water Reactor (PWR) which has the innovative feature of hybrid safety systems (optimum combination of passive safety system and active safety system) and passive core cooling by horizontal steam generators during Loss of Coolant Accident (LOCA). In order to confirm the capability of this passive core cooling system during LOCAs, the thermal-hydraulic tests of horizontal steam generator and the integral thermal-hydraulic tests simulating the LOCAs were performed. The thermal-hydraulic tests of horizontal steam generator consist of a single tube test and a multi-tubes test. On the basis of these test results, the heat transfer characteristics of steam-water two-phase flow with noncondensable gas along a long horizontal tube is understood and the heat transfer correlation including the effect of noncondensable gas is presented. The integral thermal-hydraulic tests simulate the small LOCA ...
1995-04-23
Energy Technology Data Exchange (ETDEWEB)
Copper tubes have been widely used for water supply and heat exchangers. In such systems copper tubes often suffer from type 1 pitting-corrosion. A mechanism, of the type I pitting-corrosion on copper tubing has been presented, but a initiation mechanism of the pitting corrosion is still unknown. In this paper we aimed to clarify the initiation mechanism of the pitting corrosion. Copper-tube specimens were immersed in a circulating solution. The solution had been used for heat exchangers at a Japanese factory where the water leakage occurred by the pitting corrosion on copper tubes. The solution contained tiny precipitates resulted from corrosion of galvanized steel pipe. During the immersion test changes in the surface state of a copper tube was analyzed by in situ RAMAN (in situ Raman Spectroscopy), SEM (Scanning Electron Microscope), EPMA (Electron Probe Microanalysis), AES (Auger Electron Spectroscopy) and XPS (X-ray ...
1999-07-15
Energy Technology Data Exchange (ETDEWEB)
Three algal bioassay experiments were conducted from March 1992 through September 1993 in an area of Lake Mead that has experienced problems associated with severe nutrient enrichment. The first experiment determined the effects of elevated CO2 (700 ppm) (2xCO2), vs ambient CO2 on the natural algal assemblage without nutrient enrichment. The second experiment determined the effects of 2xCO2 on nutrient enriched bioassays and if nutrients were limiting. The third experiment examined elevated temperatures and 2xCO2. Nested climate models were used to predict changes in water temperatures and thermocline development in Las Vegas Bay. The lake model predicted an increase in mean water temperatures of 1.8 deg under a 2xCO2 scenario. A thermocline definition of 1 deg. C change per 2-m depth was applied to water temperatures developed by a lake model coupled to nested general circulation and regional-scale ...
1997-01-01
3D-nuclear heat generation in PCC-charcoal filter in TAPP-3 and 4
International Nuclear Information System (INIS)
This paper deals with the calculations of 3D nuclear heat generation profile in the charcoal filter and subsequently the commencement time of Primary Containment Cleanup (PCC) system of 540MWe Pressurized Heavy Water Reactor (PHWR). Fuel failure is predicted due to overheating of the fuel under loss of Coolant Accident (LOCA) without Emergency Core Cooling System (LOCA without ECCS). Subsequently fission product gasses along with water vapours are released to Reactor Building (RB) atmosphere. Plate-out and water trapping mechanism stabilizes the concentration of significant fission products i.e. radioiodines in about 4 hours before being circulated through charcoal filters of Containment Cleanup system. After cleaning up the RB atmosphere, it is discharged to outside atmosphere through stack. The isotopes of radioiodine emit beta and gamma radiations. Gamma radiations are partly stopped within the ...
2006-11-13
Theoretical study on device efficiency of pulsed liquid jet pump
International Nuclear Information System (INIS)
The influence of the main factors on device efficiency of pulsed liquid jet pump with gas-liquid piston is analysed, the theoretical equation and its time-averaged solution of pulsed liquid jet pump device efficiency are derived. The theoretical and experimental results show that the efficiency of transmission of energy and mass to use pulsed jet is greatly raised, compared with steady jet, in the same device of liquid jet pump. The calculating results of time-averaged efficiency of pulsed liquid jet pump are approximately in agreement with the experimental results in our and foreign countries
2001-03-01
Pumped-storage hydropower schemes
Energy Technology Data Exchange (ETDEWEB)
The general types of pumped-storage plants and considerations for determining their need, use, and selection are presented. A brief discussion of TVA's experience on two pumped-storage schemes is included. Pumped-storage plants have become an integral part of many hydropower systems. Most of these systems use pumped-storage plants to meet power requirements during the peak load demands. In any application, large or small, the expected load demand and supply source must be identified to select the best scheme required for the particular system.
1984-01-01
Energy Technology Data Exchange (ETDEWEB)
This paper presents a new algorithm for the optimal long-range generation planning for a thermal system with pumped-storage plants. The algorithm is based upon the analytical production costing model developed under the assumption of Gaussian probabilistic distribution of random load fluctuations and plant outages. The optimization problem consists of the master problem to determine the annual investment, and the pumped-storage subproblem to determine the optimal pumped-storage operation. The master problem is formulated as a Hamiltonian minimization problem, and the pumped-storage subproblem is solved using the concept of peak-shaving operation on the original load curve.
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
This paper presents a new algorithm for the optimal long-range generation planning for a thermal system with pumped-storage plants. The algorithm is based upon the analytical production costing model developed under the assumption of Gaussian probabilistic distribution of random load fluctuations and plant outages. The optimization problem consists of the master problem to determine the annual investment, and the pumped-storage subproblem to determine the optimal pumped-storage operation. The master problem is formulated as a Hamiltonian minimization problem, and the pumped-storage subproblem is solved using the concept of peak-shaving operation on the original load curve.
1987-05-01
Geothermal heat pump applications: Industrial/commercial
Energy Technology Data Exchange (ETDEWEB)
The fastest rate of growth in the space conditioning market has been attributed to the application of geothermal heat pumps to the industrial and commercial markets. The author reviews and provides examples of the three most popular components of a large geothermal heat pump system: geothermal earth coupling, heat pumps and heat exchangers, and building side terminals. These components are applied to three example geothermal installations: a library, an office building, and a school. Examples of energy use before and after the installation of a geothermal space conditioning system are summarized. General design and cost guidelines and comments on the use of geothermal heat pump in these and similar applications are discussed.
1999-07-01
International Nuclear Information System (INIS)
The paper deals with the exploitation of the pumped storage plants for the control of the Slovak power system. For that purpose current utilization of pumped storage plants currently in operation was analyzed from the point of view of their part in the operation control of the Slovak power system. The aim of this analysis was to exploit knowledge gained so far for the future outlook up to the year 2010, including the evaluation of the need to construct pumped storage plant Ipel with a weekly storage cycle. (author).
1997-05-13
A study on diagnostic techniques of pump operating condition
Energy Technology Data Exchange (ETDEWEB)
The scope and contents investigate and reviewed are as follows : establishment of study plan and references survey, review of related problems and inservice test standards of safety injection pump in use nuclear power plant, review of the study results in laboratory, the theoretical investigation of temperature rise according to mini-flow rate of pump, mini-flow rate working characteristics of high and low pressure injection pumps at nuclear power plants, setup of testing equipment for measuring ampere, discharge pressure and vibration, selection and behaviors analysis of major parameters concerning pump degradation.
1998-03-15
Energy Technology Data Exchange (ETDEWEB)
SKB is currently performing site investigations at two potential sites for a final repository for spent nuclear fuel. This report presents results of water flow and solute transport modelling of the Forsmark site. The modelling reported in this document focused on the near-surface groundwater, i.e. groundwater in Quaternary deposits and shallow rock, and surface water systems, and was performed using the MIKE SHE tool. The most recent site data used in the modelling were delivered in the Forsmark 2.3 dataset, which had its 'data freeze' on March 31, 2007. The present modelling is performed in support of the final version of the Forsmark site description that is produced during the site investigation phase. In this work, the hydrological modelling system MIKE SHE has been used to describe near-surface groundwater flow and the contact between groundwater and surface water at the Forsmark site. The surface ...
2008-09-15
Data Center Energy Benchmarking: Part 3 - Case Study on an ITEquipment-testing Center (No. 20)
Energy Technology Data Exchange (ETDEWEB)
The data center in this study had a total floor area of 3,024 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 147 racks, and was located in a 96,000 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but was served by the main building chiller plant and make-up air system. Additionally it was served by only a single electrical supply with no provision for backup power in the event of a power outage. The Data Center operated on a 24 hour per day, year-round cycle, and users had full-hour access to the data center facility. The study found that data center computer load accounted for 15% of the overall building electrical load, while the total power consumption attributable to the data center including allocated cooling load and lighting was 22% of the total ...
2007-07-01
Energy Technology Data Exchange (ETDEWEB)
Water power plants mean the design, configuration, execution and operation of buildings and of hydraulic and electrical machines. Their many types are due to the stages of development and the technical alternatives of the use of waterpower and the associated energy economy aspects. The main points of this work are the use of water power, different hydro-electric powerstations, water collection, machines and electrotechnical equipment. In the 2nd revised edition parts on electrical engineering, environment, minimum water run-off pumped storage plants, small scole plants, economical aspects and finite elements were broadened. It is a comprehensive textbook and technical book for students of civil engineering and particularly suitable for engineers active in the theory and practice of waterpower construction. (orig./GL) [Deutsch] Wasserkraftanlagen bedeuten Planung, Gestaltung, ...
1998-12-01
Energy Technology Data Exchange (ETDEWEB)
Water power plants mean the design, configuration, execution and operation of buildings and of hydraulic and electrical machines. Their many types are due to the stages of development and the technical alternatives of the use of waterpower and the associated energy economy aspects. The main points of this work are the use of water power, different hydro-electric powerstations, water collection, machines and electrotechnical equipment. In the 2nd revised edition parts on electrical engineering, environment, minimum water run-off pumped storage plants, small scole plants, economical aspects and finite elements were broadened. It is a comprehensive textbook and technical book for students of civil engineering and particularly suitable for engineers active in the theory and practice of waterpower construction. (orig./GL) [German] Dieses Standardwerk der Wasserkraft liegt hiermit bereits ...
2005-07-01
Hitch code capabilities for modeling AVT chemistry
International Nuclear Information System (INIS)
Several types of corrosion have damaged alloy 600 tubing in the secondary side of steam generators. The types of corrosion include wastage, denting, intergranular attack, stress corrosion, erosion-corrosion, etc. The environments which cause attack may originate from leaks of cooling water into the condensate, etc. When the contaminated feedwater is pumped into the generator, the impurities may concentrate first 200 to 400 fold in the bulk water, depending on the blowdown, and then further to saturation and dryness in heated tube support plate crevices. Characterization of local solution chemistries is the first step to predict and correct the type of corrosion that can occur. The pH is of particular importance because it is a major factor governing the rate of corrosion reactions. The pH of a solution at high temperature is not the same as the ambient temperature, since ionic dissociation constants, solubility and ...
1985-03-01
Energy Technology Data Exchange (ETDEWEB)
The generation of thermal energy is the great importance for the agribusiness of dairy industry to conservation the quality of milk, taking into account that the electricity is the main source currently used for the thermal energy input. The small agribusiness dairy industry currently practiced in Brazil faces several problems related to the cost of electricity and the distance of rural properties of networks of power. In the current scenario of Brazilian dairy production, there is need for the generation of cold for the milk cooling, and also the heat for the production of hot water around 50 deg C to 60 deg C and also for cleaning of equipment used for milk production and processing. The main objective of this study is the modeling and simulation of integrated recovery process of solid waste, effluents and bioconversion. The specific project objectives are: comparison study of options and technological routes of low cost material for power generation using ...
2008-07-01
Radiation resistance of flexible graphites
International Nuclear Information System (INIS)
Polymer sealing parts are widely used in various branches of engineering as detachable joints that operate at normal and cryogenic temperatures. They are also used in nuclear-power engineering to seal pumps, pipelines, etc., where they operate at 600-650 K under a neutron fluence of around 10"1"6 cm"-"2 (E #>=# 0.18 MeV) and concomitant #gamma#-irradiation of about 10"6 R. The fluoroplastic-based materials currently used degrade when irradiated in water at 320-360 K with a neutron fluence of 10"1"5 cm"-"2 (thermal neutrons) or 10"1"4 cm"-"2 (fast neutrons), and a concomitant #gamma#-irradiation dose of 2 x 10"6 R. The strength of these fluoroplastics decreases markedly after #gamma#-irradiation (from a cobalt source) at room temperature at doses above 10"6 R. For this reason, flexible and swelling graphites are finding ever increasing application. Graflex foils made of extra-pure natural graphite were found to be radiation-resistant and ...
Numerical analysis of the mixing and recombination in the downcomer of an internal pump BWR
Energy Technology Data Exchange (ETDEWEB)
The mixing process of feedwater and reactor water in the downcomer of an internal-pump BWR (Forsmark 1 and 2) has been numerically modelled by means of a CFD-code (FLUENT/UNS). Earlier studies with a very rough model, have shown that a new sparger design is necessary to achieve an effective HWC through improved mixing in the downcomer,. This requires detailed and accurate modelling of the flow, not only for determining the mixing quality but for avoiding negative effects like increased thermal loading of internal parts. Through three 22.5deg models containing a sparger end and half the region between spargers, the principles of a new design have been defined. Their length scales range from 7-14 mm to ca 12 m. Also the steam separator region has been incorporated in the models. A 90deg model shows that they are sufficiently accurate for the actual region. The results cannot be generalised to other regions between spargers due to geometrical ...
1997-12-31
Large turbine, central power generation on offshore production facilities
Energy Technology Data Exchange (ETDEWEB)
A case study of a hypothetical offshore production fixed leg platform facility is presented. The purpose of the case study is to demonstrate the advantages offered by modern, fuel efficient large gas turbines in central power generation service for offshore production. The case study was presented using the Rolls- Royce RB211 large gas turbine with facility production of approximately 240,000 BPD of oil and 540 MMSCFD of associated gas. The gas was subjected to three stages of separation for removal of hydrocarbon liquids and water. The liquids, natural gas, and crude oil were exported from the production platform to an onshore receiving terminal. Gas compression is the service that requires the greatest amount of power for any given production facility. For this case study, gas compression represented approximately 70 per cent of the power load with the remainder represented by the liquid export pumps (16 per cent), and by general utilities ...
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
Cold Heavy Oil Production with Sand (CHOPS) is an enhanced oil recovery method that induces sand production to form a network of wormholes that increase the porosity and permeability of a formation. Under proper conditions, CHOPS can improve formation flow characteristics. Integrated well completion strategies that were used to increase oil production at Fula oil field on the south flank of Mughad Basin in Sudan were described. Limited sand influx provided a means for effective sand control while eliminating the need for conventional sand control processes. Cold heavy oil production with limited sand influx requires optimized completion methods to stimulate sand production, thereby reducing oil flow resistance and prolonging the sand removal operation cycle. Completion tests were performed in terms of different formation conditions including perforating completion; perforating and full sand control completion by screen liner; and perforating and limited sand control completion by ...
2005-11-01
Energy Technology Data Exchange (ETDEWEB)
An initial review was conducted of the current treatment operations for remediation of groundwater contaminated with trichloroethene (TCE) at the Fort lewis Logistics Center. Results from this review indicate the two pump-and-treat systems are effectively containing the TCE plume within the upper unconfined aquifer (Vashon Drift). However, mass balance calculations show the existing treatment systems alone will not accomplish the remedial action objective of cleaning up the aquifer to drinking water standards within 30 years as specified in the Record of Decision (ROD). This conclusion is based on the estimated mass of TCE at the source term (51,000 kg), the calculated mass of TCE in the aquifer (4,900 kg), and the removal rate of the pump-and-treat systems that currently ranges from 324 to 667 kg of TCe per year. Four areas within the TCE plume have been identified where enhancements could be made to the existing treatment ...
1998-07-01
Energy Technology Data Exchange (ETDEWEB)
The high-purity-oxygen activated sludge process will be used to expand secondary treatment capacity and improve water quality in Santa Monica Bay. The facility is operated by the city of Los Angeles Department of Public Works` Bureau of Sanitation. The overall Hyperion Full Secondary Project is 30% complete, including a new headworks, a new primary clarifier battery, an electrical switch yard, and additional support facilities. The upgrading of secondary facilities is 50% complete, and construction of the digester facilities, the waste-activated sludge thickening facility, and the second phase of the three-phase modification to existing primary clarifier batteries has just begun. The expansion program will provide a maximum monthly design capacity of 19,723 L/s(450 mgd). Hyperion`s expansion program uses industrial treatment techniques rarely attempted in a municipal facility, particularly on such a large scale, including: a user-friendly intermediate ...
1993-09-01
True and measured outgassing rates of a vacuum chamber with a reversibly adsorbed phase
Energy Technology Data Exchange (ETDEWEB)
A pump down model for a vacuum chamber with a reversibly adsorbed phase is presented. The outgassing equation which predicts the variation of coverage at the wall surface of a vacuum chamber with time is derived. Then the measured and the true outgassing rates are defined. The theoretical measured outgassing rate shows only a very weak dependence for pumping speed. This prediction is opposite to the experimental result that the measured outgassing rate depends significantly on pumping speed. It is discussed that the experimental measured outgassing rate must be described as the product of the effective pumping speed and the measured pressure in the pumped chamber, in which the measured pressure is equivalent to the equilibrium pressure of the wall surface described by the equilibrium adsorption isotherm as a function of the shifted surface coverage {theta}-{delta}{theta} by a small ...
2000-03-01
Report documents O M at pumped-storage plants
Energy Technology Data Exchange (ETDEWEB)
The Electric Power Research Institute has published a report for planners, designers, owners, and operators of hydroelectric pumped-storage plants that records the operation and maintenance knowledge of 35 domestic and foreign pumped-storage projects. The report provides a comprehensive record of practices that have reduced forced outages and shortened scheduled repairs. As time passes and experienced staff retire at pumped-storage plants, many O M lessons are lost. To remedy that situation, EPRI commissioned Morrison-Knudsen Engineers Inc. to prepare a special report. The 348-page publication records the accumulated civil, geotechnical, mechanical, and electrical O M knowledge and experiences of pumped-storage plant staff. It also includes recommendations to planners and designers of future pumped-storage plants and concludes with descriptions of O M experiences reported by plant ...
1991-12-01
Energy Technology Data Exchange (ETDEWEB)
To examine the hormonal regulation of the ATP-dependent Ca{sup 2+} pump in the kidneys, the ATP-dependent Ca{sup 2+} uptake by the basolateral membrane vesicles in the renal cortex was measured using radioactive calcium ({sup 45}Ca{sup 2+}) in rats with vitamin D deficiency or rats undergoing thyroparathyroidectomy. The V{sub max} of the Ca{sup 2+} pump activity was increased not only by administering calcitriol, but also by normalizing the serum calcium level in vitamin D-deficient rats. PTH suppressed the Ca{sup 2+} pump activity in normocalcemic vitamin D-deficient rats. Thyroparathyroidectomy did not affect the Ca{sup 2+} pump activity in the kidneys of normal rats. It was concluded that the ATP-dependent Ca{sup 2+} pump activity was depressed by secondary hyperparathyroidism in vitamin D-deficient rats. (author).
1990-01-01
International Nuclear Information System (INIS)
To examine the hormonal regulation of the ATP-dependent Ca"2"+ pump in the kidneys, the ATP-dependent Ca"2"+ uptake by the basolateral membrane vesicles in the renal cortex was measured using radioactive calcium ("4"5Ca"2"+) in rats with vitamin D deficiency or rats undergoing thyroparathyroidectomy. The V_m_a_x of the Ca"2"+ pump activity was increased not only by administering calcitriol, but also by normalizing the serum calcium level in vitamin D-deficient rats. PTH suppressed the Ca"2"+ pump activity in normocalcemic vitamin D-deficient rats. Thyroparathyroidectomy did not affect the Ca"2"+ pump activity in the kidneys of normal rats. It was concluded that the ATP-dependent Ca"2"+ pump activity was depressed by secondary hyperparathyroidism in vitamin D-deficient rats. (author).
Bidding strategy for pumped-storage plant in pool-based electricity market
Energy Technology Data Exchange (ETDEWEB)
This paper develops optimal bidding strategies for a pumped-storage plant in a pool-based electricity market. In the competitive regime, when compared to simple hydroelectric generator, profit of the pumped-storage plant is maximized by operating it as a generator when market clearing price is high and as a pump when the price is low. Based on forecasted hourly market clearing price, a multistage looping algorithm to maximize the profit of a pumped-storage plant is developed, considering both the spinning and non-spinning reserve bids and meeting the technical operating constraints of the plant. The proposed model is adaptive for the nonlinear three-dimensional relationship between the power produced, the energy stored, and the head of the associated reservoir. Different operating cycles for a realistic pumped-storage plant are considered and simulation results are reported and ...
2010-03-15
Benefits and applications of modular hydroelectric pumped storage
International Nuclear Information System (INIS)
This paper reports on hydroelectric pumped storage which is the only proven and most efficient technology available for energy storage. It is used by utilities to provide peak and intermediate power and to optimize overall system performance. Because of increased environmental and regulatory constraints, few acceptable sites, long schedules, and huge financial commitments, large conventional pumped storage plants, are now virtually impossible to build. As an alternative, small modular pumped storage, with project sizes ranging from 25 MW to 200 MW, was created to overcome the difficulties of conventional projects. The modular approach involves standardizing the elements of a pumped storage plant by utilizing specialized siting techniques and optimizing design, equipment, and construction. Compared with conventional pumped storage, the modular design can reduce cost and expedite ...
1991-07-24
Natural gas in Lake Erie: a reconnaissance survey of discharges from an offshore drilling rig
Energy Technology Data Exchange (ETDEWEB)
Field studies were conducted May 28-June 1, 1979, to determine the chemical composition and physical behavior of discharges from an offshore gas drilling rig in the central basin of Lake Erie. The drilling operation was observed for four days, from rig jackup to the circulation of mud through the borehole after drilling had been completed. Resuspension studies using nephelometry, supplemented with chemical analyses, indicated little resuspension of lake bottom materials or release of metals to the water column during rig jack-up. Portions of the turbidity plumes generated during drilling were buoyant. Three surface turbidity plumes were mapped with nephelometry to a point at which particulate concentrations reached background levels in the Lake. Detectable plumes were approx. 400 to 1500 m in length and had maximum widths < 230 m. A chemical survey conducted in the plume during early gas shows indicated that discharged inorganic chemical ...
1980-10-01
Flow Vaporization of CO{sub 2} in Microchannel Tubes
Energy Technology Data Exchange (ETDEWEB)
Carbon dioxide is receiving renewed interest as an efficient and environmentally safe refrigerant in a number of applications, including mobile air conditioning and heat pump systems, and hot water heat pumps. Compact heat exchangers for CO{sub 2} systems are designed with small-diameter tubing. The purpose of this study is therefore to provide a better basis for understanding and predicting heat transfer and pressure drop during flow vaporization of CO{sub 2} in microchannels. The ''unusual'' properties of carbon dioxide give heat transfer and two-phase flow characteristics that are very different from those of conventional refrigerants. Examples of these differences are the much higher pressure, the resulting high vapour density, a very low surface tension, and a low liquid viscosity. High pressure and low surface tension has a major effect on nucleate boiling characteristics, and ...
2002-07-01
Supporting Thermal Hydraulic Calculations for the SGTR Event Tree of SMART Level 1 PSA
International Nuclear Information System (INIS)
SMART (System integrated Modular Advanced ReacTor) , is under development at the Korea Atomic Energy Research Institute (KAERI). SMART is an integral type pressurized water reactor which contains a pressurizer, 4 reactor coolant pumps (RCPs), and 8 steam generator cassettes(S/Gs) in a single reactor vessel. This reactor has substantially enhanced its safety with an integral layout of its major components, 4 trains of safety injection system (SIS), and an adoption of 4 trains of passive residual heat removal system (PRHRS) instead of an active auxiliary feedwater system . The thermal power is 330 MWth. During the conceptual design stage, a preliminary PSA was performed. PSA results identified that a steam generator tube rupture (SGTR) is one of the most important initiating events which results in a high core damage frequency. Clear understanding of accident progression with various combinations of the safety systems helps to develop an event ...
2010-10-01
Energy Technology Data Exchange (ETDEWEB)
An approximate solution was proposed in which a sensitivity analysis by the storage and release of heat was performed for the subject issues and in which an operating method was thereby determined for the equipment constituting the system by means of a linear programming. Accordingly, a heat storage type energy supply system for a district cooling and heating was taken up as a concrete object to be examined. This system consisted of a gas turbine generator, initial power receiving equipment, gas boiler, electric heat pump for ice heat storage, cooling tower, heat exchanger, steam absorbing refrigerating machine, ice heat storage tank, cold and warm water heat storage tank, etc. As a result of comparison between the proposed method and the resolving method, the former showed -0.92 to 2.58% in the increase in the operating cost compared with the latter. A case where the operating cost of the resolving method was sometimes larger than the proposed ...
1996-02-01
Reduction of combustion emissions using hydrogen peroxide in a pilot scale combustion chamber
Energy Technology Data Exchange (ETDEWEB)
A hydrogen peroxide injection system was designed and installed in the stack of a 5,274 million J/hr industrial pilot plant scale combustion chamber using natural gas as fuel. The concentration of peroxide in the gas stream was precisely controlled by continuous injection using an electromagnetic dosage pump, the liquid 50% peroxide solution was finely dispersed into the gases by a water cooled custom designed delivery system with a spray nozzle at the tip. Residence times between 0.1 and 1.8 seconds and concentrations of H{sub 2}O{sub 2} between 280 ppm and 4,000 ppm were used during the test runs. CEMS for total hydrocarbons, carbon monoxide, nitrogen oxides, as well as an ultrasonic gas flow monitor were used to measure the effect of hydrogen peroxide in reducing the emissions of these pollutants. Destruction removal efficiencies between 25% and 100% were observed for hydrocarbons, and concentrations of CO, as well as NO{sub x}. were reduced ...
1997-12-31
Pumps and compressors - buyers` guide 1996/`97; Pumpen und Kompressoren - Einkaufsfuehrer 1996/97
Energy Technology Data Exchange (ETDEWEB)
The 1996/`97 buyers` guide comprises ten chapters: 1. List of suppliers; 2. Waste management, effluents, sewage systems; 3. Water supply, hydroengineering; 4. Chemistry, petrochemistry; 5. Chemical engineering; 6. Food industry, biotechnology; 7. Paper and cellulose industry; 8. Natural gas industry, natural gas supply; 9. Power plant engineering, power systems, district heating; 10. Air conditioning and refrigeration engineering. (orig.) [Deutsch] Der vorliegende Einkaufsfuehrer 1996/97 ist in zehn Kapiteln gegliedert. Diese sind: 1. Firmenverzeichnis 2-11 2. Entsorgungs-/Abwassertechnik, Klaeranlagen 12-15 3. Wasserversorgung, Wassertechnik 16-18 4. Chemie, Petrochemie 19-22 5. Verfahrenstechnik 23-26 6. Lebensmittelindustrie, Biotechnik 27-29 7. Papier-, Zeluloseindustrie 30-31 8. Erdgasindustrie, -versorgung 32 9. Kraftwerkstechnik, Energieanlagen, Fernwaerme 33-34 10. Kaelte-/Klimatechnik 35-36. (orig.)
1996-12-01
Leak-before-break strategy for CANDU primary piping systems
Energy Technology Data Exchange (ETDEWEB)
Recent advances in elastic-plastic fracture mechanics have made it possible to assess the stability of cracks in ductile piping systems. These technological developments have been used by Ontario Hydro as the nucleus of an approach for demonstrating that CANDU primary heat transport piping systems will not break catastrophically; at worst they would leak at a detectable rate. This leak-before-break approach has been taken on the Darlington nuclear generating station as a design stage alternative to the provision of pipe whip restraints on large diameter, primary heat transport system piping. Positive conclusions reached via this approach are considered sufficient to exclude the requirement to provide protective devices, such as pipe whip restraints. In arriving at the proposed leak-before-break approach a review of current and proposed leak-before-break licensing positions of other jurisdictions (particularly those in the United States and the Federal Republic of Germany) was carried ...
1986-01-01
Large temperature differential thermal storage system. Its design and evaluation
Energy Technology Data Exchange (ETDEWEB)
A large temperature differential (10K) thermal storage system in a small (4400 m{sup 2}) 8-storey office building is discussed and the monitoring results are analyzed in comparison with computer simulations. Requirements were a comfortable indoor environment and system cost effectiveness. Out of four potential system concepts, the Large Temperature Differential System was chosen. It comprises a flat-type thermal stratification heat storage tank in the under floor pit of the building as the heat source for a variable flow heat pump chiller. The heat sink is a set of serially connected air handling and fan coil units. The tank`s capacity is sized for one day operation and is made as large as possible to shift the electricity demand to night time. To avoid a large size and high cost, the water temperature differential was enlarged. The role of Tokyo Electric Power Company (TEPCO) was to develop the chiller and its control system. It is concluded ...
1996-07-01
Design of a welltest for determining two-phase hydraulic properties
Energy Technology Data Exchange (ETDEWEB)
This report describes the design of a well test to determine two-phase hydraulic properties of a low permeability, low porosity formation. Estimation of gas-related parameters in such formations is difficult using standard pumping tests mainly because of the strong fluctuations in the pressure and flow rate data which are a consequence of gas bubbles evolving in the test interval. Even more important is the fact that the data do not allow distinguishing among alternative conceptual models. The estimated parameters are therefore uncertain, highly correlated, and ambiguous. In this study we examine a test sequence that could be appended to a standard hydraulic testing program. It is shown that performing a series of water and gas injection tests significantly reduces parameter correlations, thus decreasing the estimation error. Moreover, the extended test sequence makes possible the identification of the model that describes relative ...
1995-01-01
CATHENA simulation of the WOLSUNG D_20 spill incident of 1984 November 25
International Nuclear Information System (INIS)
The CATHENA (formerly ATHENA) has been used to simulate the thermalhydraulic behaviour of the WOLSUNG-1 CANDU-600 reactor during the D_20 spill incident of 1984 November 25. A 4-inch (nominal) Liquid Relief Valve inadvertently opened in the reactor auxiliary system during normal reactor operation, resulting in a discharge of heavy water from the primary heat transport system. The valve remained open for approximately 29 minutes. CATHENA is an advanced thermalhydraulic computer code for analysis of postulated loss-of-coolant accidents (LOCA) and transient faults in CANDU nuclear reactors. A full two-fluid (six-equation) representation of the two-phase flow is used. Component models are used to represent pumps, valves, critical discharge, etc., which are necessary to describe the behaviour of the CANDU system under upset conditions. Heat transfer between the fluid and piping walls (or fuel) is modelled using applicable correlations for boiling, ...
1986-06-09
Break Nodalization Influence to IAEA-SPE-4 Test Simulation
International Nuclear Information System (INIS)
A small break LOCA event simulation with no high pressure injection system available, known as International Atomic Energy Agency Standard Problem Exercise no. 4 (IAEA-SPE-4), was performed on the PMK-2 integral test facility in Budapest in 1993. This paper analyses the response of the PMK-2 facility, a model of VVER-440 nuclear power plant, using the latest released version MOD3.2.1.2 of the RELAP5 thermal-hydraulic code. After several years of the SPE-4 experiment analyses, many problems have emerged and been studied. Main goal of the present analyses was to study the main influencing parameters for adequate modelling of the hexagonal core channel with 19-rod bundle and phenomena during the core uncovery. Some influencing parameters have been identified, mostly on the primary side, but some also on the secondary side. This is exact simulation of main coolant pump coast down, hydro-accumulators water temperature and connections to the primary ...
1998-06-15
Energy Technology Data Exchange (ETDEWEB)
A 4-loop Pressurised Water Reactor (PWR) primary coolant system has been analysed for the postulated Loss of Coolant Accident (LOCA) event in order to derive peak dynamic loads for qualifying the design of equipment supports and pipe whip restraints. Pipe whip restraints as well as pipe and equipment supports are nonlinear by nature because of the presence of gaps and the different directional stiffnesses arising from snubber, steelwork and geometric and material interaction at the concrete to steel embedment. The different structural idealisations for the supports and restraints have an influence on the dynamic response of the structure. In the first of the two part paper a range of idealisation models for the Steam Generator and Reactor Coolant Pump vertical columns ranging from elastic stiffnesses to bilinear stiffnesses with or without preload were examined. Due to both structural and loading complexity, the behaviour of these supports were ...
1993-07-01
A New and Sound Technology for Biogas from Solid Waste and Biomass
International Nuclear Information System (INIS)
Organic waste, as a main constituent of municipal solid waste, has as well as solid biomass a high potential for biogas generation. Despite the importance of biogas generation from these materials, the availability of large-scale biogas processes lacks behind the demand. A newly developed double-stage solid-liquid biogas process, consisting of an open hydrolysis stage and a fixed-bed methane reactor, allows the biogas production from almost all biodegradable solid waste and renewable resources like maize, grass, sugar cane, etc. Furthermore, residues from industrial processes, like the glycerine waste water from biodiesel production, can also be converted into biogas successfully. Due to the strong separation of hydrolysis and methanation, the process is extremely stable. No malfunction has been detected so far. The open hydrolysis releases CO_2 and allows oxidation of sulfur. Consequently, the biogas has a high methane (>72%) and low H_2S concentration (<100 ...
2009-04-01
System Analysis for Decay Heat Removal in Lead-Bismuth Cooled Natural Circulated Reactors
Decay heat removal analyses for lead-bismuth cooled natural circulation reactors are described in this paper. A combined multi-dimensional plant dynamics code (MSG-COPD) has been developed to conduct the system analysis for the natural circulation reactors. For the preliminary study, transient analysis has been performed for a 100 MWe lead-bismuth-cooled reactor designed by Argonne National Laboratory (ANL). In addition, decay heat removal characteristics of a 400 MWe lead-bismuth-cooled natural circulation reactor designed by Japan Nuclear Cycle Development Institute (JNC) has been evaluated by using MSG-COPD. PRACS (Primary Reactor Auxiliary Cooling System) is prepared for the JNC's concept to get sufficient heat removal capacity. During 2000 sec after the transient, the outlet temperature shows increasing tendency up to the maximum temperature of 430 Centigrade, because the buoyancy force in a primary ...
2002-07-01
Coolant rate distribution in horizontal steam generator under natural circulation
International Nuclear Information System (INIS)
The interrelations between the factors causing the main effects on the primary circuit coolant flow rate distribution in the horizontal steam generator pipes in reactor facilities with the WWER type reactors under the modes with natural circulation are discussed. The criterion showing the presence or absence of coolant circulation reversal in bottom rows of the steam generator pipes is obtained. It is shown that large hydraulic non-uniformity in steam generator pipes operating in parallel under coolant natural circulation leads to decreasing the heat transfer surface efficiency under reactor facility emergency cooling, restricts its servicing capabilities. The circulation reverse in steam generator pipes under coolant natural circulation mode can give unfavourable effect on separate structural elements of the steam generators and as a result it can cause additional temperature ...
1997-09-01
Enhanced LMR core cooling utilizing passive vortex devices
International Nuclear Information System (INIS)
This paper reports several design options for improved passive circulation flow investigated for use in small, modular liquid metal cooled reactors (LMRs). The purpose is to enhance the transition to natural convection cooling following loss of forced circulation flow, reducing thermal transients experienced by the fuel and possibly eliminating the need for emergency pony-motor flow. Design details to minimize pressure drops may also enhance maximum equilibrium power levels possible under natural circulation only.
1988-05-01
Enhanced LMR [liquid metal reactors] core cooling utilizing passive vortex devices
International Nuclear Information System (INIS)
Several design options for improved passive circulation flow have been investigated for use in small, modular liquid metal cooled reactors (LMRs). The purpose is to enhance the transition to natural convection cooling following loss of forced circulation flow, reducing thermal transients experienced by the fuel and possibly eliminating the need for emergency pony-motor flow. Design details to minimize pressure drops may also enhance maximum equilibrium power levels possible under natural circulation only.
1988-05-01
Energy Technology Data Exchange (ETDEWEB)
As part of the ICAP (International Code Assessment and Applications Program) agreement between ECN (Netherlands Energy Research Foundation) and USNRC, ECN has performed a number of assessment calculations for the thermohydraulic system analysis code RELAP5/MOD2/36.05. This document describes the assessment of this computer program versus a natural circulation experiment as conducted at the Borssele Nuclear Power Plant. The results of this comparison show that the code RELAP5/MOD2 predicts well the natural circulation behaviour of Nuclear Power Plant Borssele.
1993-07-01
Steam-water two-phase flow in large diameter vertical piping at high pressures and temperatures
Energy Technology Data Exchange (ETDEWEB)
No information on steam/water two-phase flow behavior in large diameter pipes (10 inch or larger) at elevated pressures is available in the open literature. However, there are many applications, in the nuclear, chemical and petroleum industries among others where two-phase flows in large diameter pipes at elevated pressures and temperatures are encountered routinely or under accident scenarios. Experimental data on steam-water two-phase flow in a large diameter (20 inch, 50.08 cm I.D.) vertical pipe at elevated pressures and temperatures (2.8 MPa/230 C--6.4 MPa/280 C) have been obtained. Void fraction, two-phase mass flux, phase and velocity distributions as well as pressure drop along the test pipe have been measured using the Ontario Hydro Technologies (OHT) Pump Test Loop. The void fraction distributions were found to be axially symmetric and nearly flat over a wide range of two-phase flow conditions. The two-phase flow ...
1996-08-01
Steam-water two-phase flow in large diameter vertical piping at high pressures and temperatures
International Nuclear Information System (INIS)
No information on steam/water two-phase flow behavior in large diameter pipes (10 inch or larger) at elevated pressures is available in the open literature. However, there are many applications, in the nuclear, chemical and petroleum industries among others where two-phase flows in large diameter pipes at elevated pressures and temperatures are encountered routinely or under accident scenarios. Experimental data on steam-water two-phase flow in a large diameter (20 inch, 50.08 cm I.D.) vertical pipe at elevated pressures and temperatures (2.8 MPa/230 C--6.4 MPa/280 C) have been obtained. Void fraction, two-phase mass flux, phase and velocity distributions as well as pressure drop along the test pipe have been measured using the Ontario Hydro Technologies (OHT) Pump Test Loop. The void fraction distributions were found to be axially symmetric and nearly flat over a wide range of two-phase flow conditions. The two-phase flow ...
1996-03-10
Energy Technology Data Exchange (ETDEWEB)
Microorganisms associated with fractured basalt core were compared to those suspended in groundwater pumped from the same well in the eastern Snake River Plain Aquifer (Idaho, USA). Two wells influenced to different degrees by a mixed-waste plume in the fractured basalt aquifer were examined. In one well, an array of dialysis cells filled with either deionized water or crushed basalt was equilibrated to compare the microorganisms collected in this fashion with those from core and groundwater samples collected in a traditional manner from the same well. Analyses were performed to characterize these samples and to provide a basis for comparison. These included total cell counts by microscopy; total biomass by phospholipid fatty acid analysis; enumerations of viable aerobic heterotrophs, groups of putative aerobic co-metabolic TCE-degraders and aerobic H2-oxidizing bacteria; mineralization of 14C- labeled acetate; and enrichments for dissimilatory ...
2004-04-01
Influence of Hexagenia on the fate and bioavailability of contaminants in sediment
International Nuclear Information System (INIS)
The influence of sediment dwelling macroinvertebrates on fate and bioavailability of contaminants in freshwater systems was determined using the burrowing mayfly, Hexagenia limbata, as a representative benthic organism. Two series of experiments were conducted: the first to determine the effect of mayflies on movement of contaminants into sediment and organisms, and the second to examine the effect of mayflies on release of contaminants from sediments to the water column and their subsequent accumulation in fish. Concentrations of "1"4C labelled DDT, hexachlorobenzene (HCB), and dihexylphthalate (DHP) in water were 0.11 +/- 0.01, 0.062 +/- 0.005 and 0.006 +/- 0.007 ppb, respectively. Total mass of DHP in the burrow wall was about equal to mass on the surface, indicating that mayflies were capable of doubling the amount of DHP sorbed per unit surface area of sediment. Adsorption of contaminants from water ...
Energy Technology Data Exchange (ETDEWEB)
A precise admixtures system is needed when using high-volume fly ash concrete as fresh concrete occasionally undergoes rapid slump loss after mixing, which can cause problems with casting, pumping and finishing of the concrete in hot weather. This paper provided details of a study conducted to implement high-volume fly ash concrete technology in India. Different families of admixtures were investigated to determine their water reduction capacities. A set-retarding admixture was used in some of the concrete mixtures in order to determine its efficacy. An Indian Portland cement was used to create a total of 22 different concrete mixtures. Four different fly ashes were used to replace portions of the concrete. The slump of the fresh concrete mixture was monitored for 2 to 3 hours. Unit weight and temperature of the concrete was measured. Specimens were cast in steel moulds in order to determine the compressive strength and unit weight of the ...
2006-07-01
The influence of intense intermittent versus moderate continuous exercise on postprandial lipemia
UK PubMed Central (United Kingdom)
INTRODUCTION:Postprandial lipemia is characterized by an increased concentration of circulating lipids after fat intake and is an independent risk factor for cardiovascular disease....Full Text Available
2011-04-01
The characteristics of local atmospheric circulation around the Wolsung NPP in Korea
Energy Technology Data Exchange (ETDEWEB)
The transport of air pollutants in coastal regions has been known to be strongly affected by the mesoscale atmospheric circulations such as sea-land breezes. These mesoscale atmospheric circulations depend on synoptic weather conditions. In this study, a three-dimensional sea-land breeze model was developed to evaluate the effects of the sea and land breezes on the atmospheric dispersion of radioactive materials released from nuclear power plants in Korea. In the model, the hydrostatic primitive equations in the terrain-following coordinate system were used. The mesoscale atmospheric circulation simulation were carried out under various synoptic weather conditions for all seasons around the Wolsung nuclear power plant site.
1998-12-31
The characteristics of local atmospheric circulation around the Wolsung NPP in Korea
International Nuclear Information System (INIS)
The transport of air pollutants in coastal regions has been known to be strongly affected by the mesoscale atmospheric circulations such as sea-land breezes. These mesoscale atmospheric circulations depend on synoptic weather conditions. In this study, a three-dimensional sea-land breeze model was developed to evaluate the effects of the sea and land breezes on the atmospheric dispersion of radioactive materials released from nuclear power plants in Korea. In the model, the hydrostatic primitive equations in the terrain-following coordinate system were used. The mesoscale atmospheric circulation simulation were carried out under various synoptic weather conditions for all seasons around the Wolsung nuclear power plant site.
1998-11-15
Strain-dependent variation in collateral circulatory function in mouse hindlimb
UK PubMed Central (United Kingdom)
The extent (density and diameter) of the native (preexisting) collateral circulation in healthy tissues and the capacity of collaterals to enlarge/remodel in obstructive arterial disease are important...Full Text Available
2010-08-01
Purinergic receptors in the splanchnic circulation
UK PubMed Central (United Kingdom)
There is considerable evidence that purines are vasoactive molecules involved in the regulation of blood flow. Adenosine is a well known vasodilator that also acts as a modulator of the response to...Full Text Available
2008-09-01
Pharmacological optimization of tissue perfusion
UK PubMed Central (United Kingdom)
After fluid resuscitation, vasoactive drug treatment represents the major cornerstone for correcting any major impairment of the circulation. However, debate still rages as to the choice of agent, dose,...Full Text Available
2009-07-01
Myxoviruses Monitoring in Seals Populations
International Science & Technology Center (ISTC)
Comparative Molecular Genetic Monitoring of Myxoviruses Circulating in Populations of Seals Phoca Caspia and Phoca Sibirica in Northern Caspian Region and Lake Baikal
Genetic Architecture Underlying Variation in Extent and Remodeling of the Collateral Circulation
UK PubMed Central (United Kingdom)
RationaleCollaterals are arteriole-to-arteriole anastomoses that connect adjacent arterial trees. They lessen ischemic tissue injury by serving as endogenous bypass...Full Text Available
2010-08-20
Circulating Skeletal Stem Cells
UK PubMed Central (United Kingdom)
We report the isolation of adherent, clonogenic, fibroblast-like cells with osteogenic and adipogenic potential from the blood of four mammalian species. These cells phenotypically resemble but are...Full Text Available
2001-05-28
Carbohydrate-specified endocytosis: localization of ligand in the lysosomal compartment.
UK PubMed Central (United Kingdom)
Carbohydrate-directed endocytosis is mediated by a receptor, the hepatic binding protein; it is responsible for the clearance of galactose-terminated glycoproteins from the circulation. This process...Full Text Available
1981-11-01
Seal is successful at Italys largest pumped storage plant
British Library Electronic Table of Contents (United Kingdom)
A HydroSele S seal from James Walker has provided more than two years maintenance-free service at the large Entracque pumped-storage hydroelectric scheme in Italy.
2008-01-01
Program listing for heat-pump seasonal-performance model (SPM). [CNHSPM
The computer program CNHSPM is listed which predicts heat pump seasonal energy consumption (including defrost, cyclic degradation, and supplementary heat) using steady state rating point performance and binned weather data. (LEW)
1982-06-30
Performance Assessment of Wolsung Unit 2 Safety Grade Pumps using In-Service Test
Energy Technology Data Exchange (ETDEWEB)
Nuclear power plant has several safety features and each safety feature is based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear power plant to keep operational readiness of pumps and valves by In-Service Test (IST). According to Ministry of Education, Science and Technology (MEST) Bulletin 2008-14, the safety functioned pumps and valves of all nuclear power plants of Korea Hydro and Nuclear Power Co. Ltd.(KHNP) have been tested to verify their performance of safety function. Each safety grade pump has own design requirement and should be tested to identify whether it could meet the requirement. Design requirements and test references of all safety grade pumps of Wolsung Nuclear Power Plant Unit 2 (Wolsung Unit 2) were examined in this study. And the results of the performance test of the pump were also ...
2008-10-15
Performance Assessment of Wolsung Unit 2 Safety Grade Pumps using In-Service Test
International Nuclear Information System (INIS)
Nuclear power plant has several safety features and each safety feature is based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear power plant to keep operational readiness of pumps and valves by In-Service Test (IST). According to Ministry of Education, Science and Technology (MEST) Bulletin 2008-14, the safety functioned pumps and valves of all nuclear power plants of Korea Hydro and Nuclear Power Co. Ltd.(KHNP) have been tested to verify their performance of safety function. Each safety grade pump has own design requirement and should be tested to identify whether it could meet the requirement. Design requirements and test references of all safety grade pumps of Wolsung Nuclear Power Plant Unit 2 (Wolsung Unit 2) were examined in this study. And the results of the performance test of the pump were also ...
2008-10-01
Overall control and monitoring systems for pumped storage plants
Energy Technology Data Exchange (ETDEWEB)
The article describes control and monitoring concepts in which the delegation of responsibility is becoming more decisive than ever (automation hierarchy), and which are capable of optimized, automatic control of process events in pumped storage plants. 8 refs.
1982-06-01
NASA - NASA COMPUTER ROCKET SCIENCE HELPS DEBAKEY HEART PUMP TEAM
Feb 24, 2000 ... NASA computer experts have been using a supercomputer to improve the NASA/ DeBakey miniature heart assist pump, leading to on-going human ...
Intravenous proton pump inhibitors for peptic ulcer bleeding: Clinical benefits and limits
UK PubMed Central (United Kingdom)
Peptic ulcer bleeding is a common disease and recurrent bleeding is an independent risk factor of mortality. Infusion with proton pump inhibitors (PPIs) prevents recurrent bleeding after successful...Full Text Available
2011-03-16
UK PubMed Central (United Kingdom)
Bolus infusion of insulin along with a meal is a standard procedure with continuous subcutaneous insulin infusion. Modern insulin pumps allow applying this bolus in four different ways: infusion of...Full Text Available
Geothermal heat-pump systems are competing today against conventional fuels
Energy Technology Data Exchange (ETDEWEB)
The alternative to the use of deeper wells through temperature amplification of the geothermal resource by electric heat pumps is explored. Systems in Ephrata, Washington and Chamberlain, South Dakota are explored. (MHR)
1982-12-01
Flashlamp radiation recycling for enhanced pumping efficiency and reduced thermal load
Energy Technology Data Exchange (ETDEWEB)
A method for recycling laser flashlamp radiation in selected wavelength ranges to decrease thermal loading of the solid state laser matrix while substantially maintaining the pumping efficiency of the flashlamp.
1989-01-01
Crystallographic structure of xanthorhodopsin, the light-driven proton pump with a dual chromophore
UK PubMed Central (United Kingdom)
Homologous to bacteriorhodopsin and even more to proteorhodopsin, xanthorhodopsin is a light-driven proton pump that, in addition to retinal, contains a noncovalently bound carotenoid with a function...Full Text Available
2008-10-28
UK PubMed Central (United Kingdom)
BACKGROUNDOff-pump coronary artery bypass (OPCAB) surgery is associated with a hypercoagulable state in which the platelet thrombin receptor, protease-activated receptor-1...Full Text Available
2009-11-01
Thermodynamic analysis of a hybrid geothermal heat pump system
British Library Electronic Table of Contents (United Kingdom)
A thermodynamic analysis of a hybrid geothermal heat pump system is carried out. Mass, energy, and exergy balances are applied to the system, which has a cooling tower as a heat rejection unit, and system performance is evaluated in terms of coefficient of performance and exergy efficiency. The heating coefficient of performance for the overall system is found to be 5.34, while the corresponding exergy efficiency is 63.4%. The effect of ambient temperature on the exergy destruction and exergy efficiency is investigated for the system components. The results indicate that the performance of hybrid geothermal heat pump systems is superior to air-source heat pumps.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Due to changed operational conditions and because of the increasing age of several hydro power plant components, there is an increasing risk of damages and the control of degradation mechanisms is of increasing significance. Therefore lifetime considerations for safety relevant components in pumped-storage plants become more and more important. The development of a lifetime management system, in conjunction with monitoring systems and specific surveillance for a group of pumped-storage power plants of different ages and in a wide range of power output is presented. The special focus is on the impact of fatigue strength considerations within this framework. The applied procedure will be described for typical mechanical components in pumped-storage plants exemplarily. (orig.)
2010-07-01
Residential vertical geothermal heat pump system models: Calibration to data
Energy Technology Data Exchange (ETDEWEB)
A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was tuned to better match the measured data from the site. These tuned models were then interconnected to form the system model. The system model was then exercised in order to demonstrate its capabilities.
1997-12-31
Residential Vertical Geothermal Heat Pump System Models: Calibration to Data:
Energy Technology Data Exchange (ETDEWEB)
A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was 'tuned' to better match the measured data from the site. These tuned models were then interconnect to form the system model. The system model was then exercised in order to demonatrate its capabilities.
1997-06-01
Nuclear power plants connected with pumped storage plants by the inland lakes
International Nuclear Information System (INIS)
Finnish (May 1971). Finland Kilpelaeinen, JE Imatran Voima Osakeyhtio,
1971-01-01
New crafts of a master builder
Energy Technology Data Exchange (ETDEWEB)
Innovative new ideas for the construction of homes are described. A thermal energy storage system fireplace and a geothermal heat pump for homes are described.
1983-11-01
National coordination of NPP operation: Belgian case
International Nuclear Information System (INIS)
Adjusting generation to demand (load following) is compared with practical experience. The importance of pumped storage plants is emphasized.
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
Late 1994, the Geothermal Heat Pump Consortium (GHPC) was launched as a non-profit collaborative effort between the United States Department of Energy, US electric utilities and the GeoExchange (geothermal heat pump) industry to make ''geothermal heat pumps'' a significant component of the HVAC industry and avoid 1.5 million metric tons of carbon equivalent per year. The goal was to create a self-sustainable GeoExchange market. This report offers a summary of some of the lessons learned and an overview of some of the programs major accomplishments.
2001-04-30
ASPECTS OF PERFORMANCE EVALUATION OF WATERJET ...
... Propulsive efficiency is equivalent to the product of thrust efficiency and the hull/waterjet interaction efficiency. ... t'waterjet pump Ktorque repeated ...
1967-10-01
A Generalized Simulation Model for Reservoir System ...
... Hydropower analysis may include run-of-river, peaking, and pumped storage plants as well as system power operation. ...
1992-03-01
Theory of bistability in the face-pumped laser with bimolecular recombination
Steady-state and transient behavior of the longitudinally pumped semiconductor laser is theoretically investigated by using a rate-equation model with distributed gain and photon density. Conditions necessary for bistable operation are derived. Dependencies of such major switching characteristics as turn-on and turn-off powers, delay, and rise times on laser parameters are examined. Influences of spontaneous radiation, impurities, and Auger recombination are studied. The results offer an explanation for the observed nonlinear behavior of face-pumped lasers.
1987-01-01
Renewable energy technologies for federal facilities: Geothermal heat pump
Energy Technology Data Exchange (ETDEWEB)
This sheet summarizes information on geothermal heat pumps (GHPs), which extracts heat from the ground in the winter and transfers heat to the ground in the summer. More than 200,000 GHPs are operating in US; they can reduce energy consumption and related emissions by 23 to 44% compared to air-source heat pumps. Opportunities for use of GHPs, requirements, and cost are described. Important terms are defined.
1996-05-01
Energy Technology Data Exchange (ETDEWEB)
Giving many examples, the contribution shows how pump operators may influence the life, efficiency and overall cost of their pumps. Further, it is shown that both the detection of unfavourable or non-optimal operating conditions and the identification of causes necessitate extensive knowledge and experience. (orig.)
2008-12-15
Energy Technology Data Exchange (ETDEWEB)
This book includes the latest developments and covers pump performance, selection and operations, materials, seals and packings, effective fluid characteristics, filtration, piping systems, economics, valves, instrumentation, automatic controls, power transmission equipment, pump and pipeline heating, and more. An extensive data section contains formulas, charts, symbols, nomographs, and standard specification documents.
1984-01-01
Energy Technology Data Exchange (ETDEWEB)
Pumping is one of the means for storing vast quantities of energy. This article analyses its principles and ways of implementation with emphasis on its double aspect, e.g., on the one hand, off-peak power is transferred to the periods of heaviest load and is thus valorized, even when taking into account losses due to poor efficiency of operations in the pumping and turbine modes, and on the other hand, plants have great flexibility in operation, faciliting the permanent fitting of generation to demand.
1982-09-01
Overall control and monitoring systems for pumped storage plants
Energy Technology Data Exchange (ETDEWEB)
Experience and technical innovations in power plant engineering have resulted in continuous improvements of operation control, availability and safety of pumped storage plants. Process control is constantly improved as new developments are made in equipment and systems engineering. Plant control concepts with increasingly complex automation hierarchy are described by which pumped storage processes can be controlled optimally, reliably, and automatically.
1982-01-01
New development of external-PIXE system using a differential pumping technique
International Nuclear Information System (INIS)
A new external-PIXE system utilizing a differential pumping technique, which can completely protect the accelerator and vacuum pumps when the exit foil breaks down, has been developed. Applications to analyses of liquid and heavily-outgassing samples were successfully achieved. Also, experiments for evaluating the efficiency of the system were performed and results will be presented. (author)
1999-09-01
Geothermal heat-pump systems of heat supply
International Nuclear Information System (INIS)
The data on the multilayer operation of the objects, located in the climatic conditions of the central area of Russia and equipped with the geothermal heat-pumping systems of the heat supply are presented. The results of the analytical studies on evaluating the geothermal heat-pumping systems of the heat supply integration efficiency into the structure of the energy supply system, prevailing in the country, are presented
2004-06-01
Diffusion absorption heat pump. Diffusion-Absorptions-Waermepumpe
Energy Technology Data Exchange (ETDEWEB)
The development of a gas-operated diffusion absorption heat pump for the heating of living spaces is described. By various improvement an energy efficiency of the prototypes of 1.5 was achieved. Structural alterations led to a lower overall height and lower production costs. The CFCs used in electric heat pumps were replaced by environmentally neutral ammonia. Compared with conventional gas heating systems, the CO2 output could be reduced by more than 30%. figs., tabs.
1992-02-01
National Ignition Facility Incorporates P2/E2 in Aqueous Parts Cleaning of Optics Hardware
Energy Technology Data Exchange (ETDEWEB)
When completed, Lawrence Livermore National Laboratory's (LLNL) National Ignition Facility (NIF) will be the world's largest laser with experimental capabilities applicable to stockpile stewardship, energy research, science and astrophysics. As construction of the conventional facilities nears completion, operations supporting the installation of specialized laser equipment have come online. Playing a critical role in the precision cleaning of mechanical parts from the NIF beamline are three pieces of aqueous cleaning equipment. Housed in the Optics Assembly Building (OAB), adjacent to NIF's laser bay, are the large mechanical parts gross cleaner (LMPGC), the large mechanical parts precision cleaner (LMPPC), and the small mechanical parts gross and precision cleaner (SMPGPC). These aqueous units, designed and built by Sonic Systems, Inc., of Newtown, Pennsylvania, not only accommodate parts that vary greatly in size, weight, geometry, surface finish and ...
2001-07-27
Tank 241-AZ-101 Mixer Pump Test Vapor Sampling and Analysis Plan
Energy Technology Data Exchange (ETDEWEB)
This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of mixer pumps in tank 241-AZ-101. The primary purpose of the mixer pump test (MPT) is to demonstrate that the two 300 horsepower mixer pumps installed in tank 241-AZ-101 can mobilize the settled sludge so that it can be retrieved for treatment and vitrification. Sampling will be performed in accordance with Tank 241-AZ-101 Mixer Pump Test Data Quality Objective (Banning 1999) and Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis (Mulkey 1999). The sampling will verify if current air emission estimates used in the permit application are correct and provide information for future air permit applications.
2000-04-10
British Library Electronic Table of Contents (United Kingdom)
The world of antibiotic drug discovery and development is driven by the necessity to overcome antibiotic resistance in common Gram-positive and Gram-negative pathogens. However, the lack of Gram-negative activity among both recently approved antibiotics and compounds in the developmental pipeline is a general trend despite the fact that the plethora of covered drug targets are well-conserved across the bacterial kingdom. Such intrinsic resistance in Gram-negative bacteria is largely attributed to the activity of multidrug resistance (MDR) efflux pumps. Moreover, these pumps also play a significant role in acquired clinical resistance. Together, these considerations make efflux pumps attractive targets for inhibition in that the resultant efflux pump inhibitor (EPI)/antibiotic combination d...
2006-01-01
British Library Electronic Table of Contents (United Kingdom)
Abstract The purpose of this study was to compare the HL 20 roller pump (Jostra USA, Austin, TX, USA) and Rotaflow centrifugal pump (Jostra USA) on hemodynamic energy production and gaseous microemboli (GME) delivery in a simulated neonatal cardiopulmonary bypass (CPB) circuit under nonpulsatile perfusion. This study employed a simulated model of the pediatric CPB including a Jostra HL 20 heart lung machine (or a Rotaflow centrifugal pump), a Capiox BabyRX05 oxygenator (Terumo Corporation, Tokyo, Japan), a Capiox pediatric arterial filter (Terumo Corporation), and inch tubing. The total volume of the experimental system was 700 mL (500 mL for the circuit and 200 mL for the pseudo neonatal patient). The hematocrit was maintained at 30% using human blood. At the beginning of each trial, a 5 ...
2010-01-01
Dynamic voltage control by remote voltage regulation for pumped storage plants
Energy Technology Data Exchange (ETDEWEB)
This paper presents a new application in dynamic voltage control based on an older method of voltage regulation. The resulting method is suitable for adoption inn multi-unit pumped storage plants. Inherent operation characteristics of pumped storage plants in the pumping mode can created visible load rejection overvoltages on the transmission and the nearby distribution networks and cause customer complaints. This paper proposes a method in which the on-line units' excitation system impedance compensators are utilized to reduce the magnitude of these overvoltages. This paper presents the theoretical background, computer simulation results, and the field test results at the Pacific Gas and Electric Company's Helms Pumped Storage Plant. This paper should be of interest in the areas of power system planning as well as power system operation.
1988-08-01
Development and application of a diaphragm micro-pump with piezoelectric device
British Library Electronic Table of Contents (United Kingdom)
In this study, a new type of thin, compact, and light weighed diaphragm micro-pump has been successfully developed to actuate liquid by the vibration of a diaphragm. The micro-diaphragm pump with two valves is fabricated in an aluminum case by using highly accurate CNC machine, and the cross-section dimension is 28?mm??5?mm. Both valves and diaphragm are manufactured from PDMS. The amplitude of vibration by a piezoelectric device produces an oscillating flow and alters the chamber volume by the curvature change of a diaphragm. Several experimental set-ups for performance tests in a single micro-diaphragm pump, isothermal flow open system, and a closed liquid cooling system are designed and implemented. The performance of a one-side actuating micro-diaphragm pump is affected by the design ...
2008-01-01
A vortex valve ejector combination for fluidic two diode pumps
International Nuclear Information System (INIS)
Fluidic two diode pumps have been developed for moving highly toxic and for radioactive waste liquors about chemical plant. The pumps have a cylinder into which liquor is initially sucked and then expelled. For situations where no maintenance can be carried out the need has arisen for a fluidic alternator to the solenoid ejector system used on top of the pump cylinder to supply an alternating negative/positive air supply. A fluidic air alternator has been constructed by modifying a small vortex amplifier and inserting an ejector opposite to the throat of the outlet diffuser. The vortex valve ejector is described and performance characteristics are presented. Several developments of the V.V.E. for fluidic pumping and other applications are also reported. (author).
UK PubMed Central (United Kingdom)
Cell therapy is a promising novel option for treatment of cardiovascular disease. Because the role of bone marrow-derived circulating progenitor cells (BM-CPCs) after cell therapy is less clear, we...Full Text Available
2011-09-01
HLMC Fast Reactor With Complete Natural Circulation
To seek for a promising concept of a heavy liquid metal coolant (HLMC) fast reactor plant, Japan Nuclear Cycle Development Institute (JNC) and the electric utilities conducted conceptual design study on various types of plant concepts and compared these concepts based on technical feasibility and economical perspective. The Pb-Bi cooled complete natural circulation reactor concept may attain high safety level and construction cost goal (Yen 200,000/kWe) (authors)
2002-07-01
UK PubMed Central (United Kingdom)
Seventy male Wistar rats were the recipients of labeled small lymphocytes (1.5 X 10(7) each) collected from the peripheral blood of syngeneic donors. The migrating labeled lymphocytes were traced in...Full Text Available
1978-12-01
Efficient combining of ion pumps and getter-palladium thin films
International Nuclear Information System (INIS)
Nonevaporable getters (NEGs) have been extensively studied in the last several years for their sorption properties toward many gases. In particular, an innovative alloy as a thin film by magnetron sputtering was developed and characterized at the European Organization for Nuclear Research. It is composed of Ti-Zr-V and protected by an overlayer of palladium (Pd), according to a technology for which the authors got the licence. NEG-Pd thin films used in combination with ion getter pumps is a simple, easy way to handle pumping devices for ultrahigh and extremely high vacuum applications. To show how to apply this coating technology to the internal surface of different types of ion pumps, the authors carried out several tests on pumps of various shapes, sizes (in terms of nominal pumping speed), and types (diode, noble diode, and triode). Special care was taken during the thermal cycle ...
2008-07-01
Energy Technology Data Exchange (ETDEWEB)
In a breeder-type nuclear power plant, liquid metal is used as a coolant due to the high heat capacity factor. Also, some proposals for fusion reactor blanket design include liquid metal as a possible coolant. In both cases the understanding of natural circulation of liquid-metal flow behavior is an integral part of the thermal hydraulic analysis, especially under two-phase flow conditions. Experimental investigations have been conducted to study a liquid metal two-phase natural circulation flow system. A lead-bismuth (PbBi) eutectic mixture is used as a working fluid in a heated metal walled natural circulation loop. Gas injection induces natural circulation through the gas-lift mechanism. A real-time neutron radiography system is used to visualize the two-phase mixture, specifically the interface and the flow regime. Measurements of void fraction, void fluctuation and bubble propagation are performed.
1996-06-01
International Nuclear Information System (INIS)
In a breeder-type nuclear power plant, liquid metal is used as a coolant due to the high heat capacity factor. Also, some proposals for fusion reactor blanket design include liquid metal as a possible coolant. In both cases the understanding of natural circulation of liquid-metal flow behavior is an integral part of the thermal hydraulic analysis, especially under two-phase flow conditions. Experimental investigations have been conducted to study a liquid metal two-phase natural circulation flow system. A lead-bismuth (PbBi) eutectic mixture is used as a working fluid in a heated metal walled natural circulation loop. Gas injection induces natural circulation through the gas-lift mechanism. A real-time neutron radiography system is used to visualize the two-phase mixture, specifically the interface and the flow regime. Measurements of void fraction, void fluctuation and bubble propagation are performed.
1996-03-10
Energy Technology Data Exchange (ETDEWEB)
Versatility of the TRNSYS software program, the ease with which new components can be incorporated into the software, and its application to simulate heat pump systems was discussed. A case history was described in which the package, augmented by the addition of several recent large-scale heat pump projects, was used in calibrating a residential geothermal heat pump system at a military housing project in Fort Polk, LA. The project involved retrofitting over 4000 air source heat pumps with geothermal heat pumps in an energy savings performance contract. The calibration of the component models led to a system model which accurately predicts the performance of the geothermal heat pump. The lessons learned from the calibration exercise were used to help to predict the energy savings from one of the electric feeders at the base which serves some 200 of the 4000+ ...
1997-11-01
Ground source heat for heat pumps; Erdgekoppelte Waermequellen fuer Waermepumpen
Energy Technology Data Exchange (ETDEWEB)
Under the new name of ``geothermal heat pump``, ground-source heat pumps are currently high in demand in Northern America. In sectors characterized by heating and cold air demand, their advantages can be exploited to the full. For Germany, the end-use-energy substitution potential of geothermal heat pumps has been estimated at 1310-1470 PJ annually. Whether this potential can actually be exploited depends essentially on the development of energy prices, but also on the resourcefulness of plant and heat pump manufacturers in upgrading and cheapening geothermal heat pumps. (orig./RHM) [Deutsch] Unter der neuen Bezeichnung `Geothermal Heat Pump` erlebt die erdgekoppelte Waermepumpe z.Zt. in Nordamerika einen Verbreitungsschub. In dem durch Heiz- und Kuehlbedarf charakterisierten Umfeld kann sie Ihre Vorteile voll nutzen. Fuer Deutschland kommt eine Schaetzung zu ...
1996-12-31
International Nuclear Information System (INIS)
The first Advanced Boiling Water Reactor (ABWR) started commercial operation as Tokyo Electric Power Company's (TEPCO) Kashiwazaki-Kariwa Nuclear Power Station Unit No.6 (K-6) in November 1996 and its sister Unit No.7 (K-7) in July 1997. The ABWR was developed to achieve higher reliability and safety margin while improving overall operability and economics. To achieve these goals, the optimal Boiling Water Reactor (BWR) technologies had been studied, tested and were finally adopted into the ABWR design. These technologies were called 'First of a Kind' and include the Reactor Internal Pump (RIP), Fine Motion Control Rod Drive (FMCRD), Reinforced Concrete Containment Vessel (RCCV), and integrated digital Instrumentation and Control System (I and C). Intensive development study, confirmation tests and verification tests were conducted by the plant equipment suppliers, electric utilities, and government agencies. During plant ...
1999-12-01
Radon in soil gas survey in Curitiba (Brazil)
International Nuclear Information System (INIS)
This work describes the radon in soil gas measurements performed during the last two years in cooperation between the Laboratory of Applied Nuclear Physics of the Federal University of Technology (UTFPR), the Nuclear Technology Development Center (CDTN) and the Institute of Radiation Protection and Dosimetry (IRD) from the Brazilian Nuclear Energy Commission (CNEN). Following previously concluded measurements of radon concentration in dwellings and the measurements of 222Rn activity in drinking water collected at artesian bores of Curitiba urban area, present step of activities has been dedicated to measurements of radon concentration in soil gas. Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specially developed for such measurements Soil Gas Probe through the air pump and filter system. After the Probe was inserted, the ground has been tamped down around the probe, to prevent air from moving ...
2002-10-08
Energy Technology Data Exchange (ETDEWEB)
This study of the hydrogeology of Chicken Creek Canyon wasconducted by the Environmental Restoration Program (ERP) at LawrenceBerkeley National Laboratory (LBNL). This canyon extends downhill fromBuilding 31 at LBNL to Centennial Road below. The leading edge of agroundwater tritium plume at LBNL is located at the top of the canyon.Tritium activities measured in this portion of the plume during thisstudy were approximately 3,000 picocuries/liter (pCi/L), which issignificantly less than the maximum contaminant level (MCL) for drinkingwaterof 20,000 pCi/L established by the Environmental ProtectionAgency.There are three main pathways for tritium migration beyond theLaboratory s boundary: air, surface water and groundwater flow. Thepurpose of this report is to evaluate the groundwater pathway.Hydrogeologic investigation commenced with review of historicalgeotechnical reports including 35 bore logs and 27 test pit/trench logsas well as existing ERP information from 9 ...
2007-10-31
Energy Technology Data Exchange (ETDEWEB)
Three reactive materials were evaluated at laboratory scale to identify the optimum treatment reagent for use in a Permeable Reactive Barrier Treatment System at Rocky Flats Environmental Technology Site (RFETS). The contaminants of concern (COCS) are uranium, TCE, PCE, carbon tetrachloride, americium, and vinyl chloride. The three reactive media evaluated included high carbon steel iron filings, an iron-silica alloy in the form of a foam aggregate, and a peculiar humic acid based sorbent (Humasorb from Arctech) mixed with sand. Each material was tested in the laboratory at column scale using simulated site water. All three materials showed promise for the 903 Mound Site however, the iron filings were determined to be the least expensive media. In order to validate the laboratory results, the iron filings were further tested at a pilot scale (field columns) using actual site water. Pilot test results were similar to laboratory results; ...
2000-01-01
TRITEX. A ferritic steel loop with Pb-15.8Li. Facility and operation
Energy Technology Data Exchange (ETDEWEB)
TRITEX was a pumped loop with Pb-15.8Li, fabricated from steel 1.4922. In contact with the molten eutectic were also molybdenum, vanadium and armco-iron. The loop was originally designed to investigate tritium extraction using solid getter metals. Over the years the goal changed to the study of metals, corrosion products and purification of the eutectic mixture. Therefore many modifications were done. The first part of this report describes TRITEX. All parts were enclosed in thermoboxes for a homogeneous temperature. One test section was in an argon glove box and could be opened during operation. Other special equipment`s were: permeation membranes and liquid-metal-covergas-interfaces to study the transport of H{sub 2}, D{sub 2} and {sup 3}H, different purification devices, a quartz observation window to see the liquid metal surface, 4 different kinds of flow measurements, level indicators, freeze valves. The second part describes loop operation. Between 1989 and ...
1999-05-01
Heat transfer augmentation of a circular pipe flow using nano-particle layers
International Nuclear Information System (INIS)
For the advanced fusion reactor FFHR2 (Force Free Helical Reactor) that has been proposed by NIFS, molten salt Flibe (LiF:BeF2=64:36) breeder blanket system is selected because of Flibe's features such as chemical stability, low-pressure operation and low electric conductivity. The Flibe is however high Prandtl number fluid since it has high viscosity and low thermal conductivity. Therefore its heat transfer performance is low compared with liquid Li or Pb-Li. In addition to heat removal of 1MW/m2 on the first wall, electrolysis of molten salt due to MHD effect will take place under high flow rate condition. This indicates that heat transfer enhancement under low flow rate is essential for the Flibe blanket system. In our laboratory, heat transfer characteristics of molten salt HTS (KNO3:NaNO2:NaNO3=53:40:7), have been evaluated, which is used as a simulant fluid of Flibe from the points of view of Be's toxicity and similar Prandtl number. In this paper, we adopt nano-particle layer ...
2007-10-05
Study on thermal-hydraulics during a PWR reflood phase
International Nuclear Information System (INIS)
In-core thermal-hydraulics during a PWR reflood phase following a large-break LOCA are quite unique in comparison with two-phase flow which has been studied widely in previous researches, because the geometry of the flow path is complicated (bundle geometry) and water is at extremely low superficial velocity and almost under stagnant condition. Hence, some phenomena realized during a PWR reflood phase are not understood enough and appropriate analytical models have not been developed, although they are important in a viewpoint of reactor safety evaluation. Therefore, author investigated some phenomena specified as important issues for quantitative prediction, i.e. (1) void fraction in a bundle during a PWR reflood phase, (2) effect of radial core power profile on reflood behavior, (3) effect of combined emergency core coolant injection on reflood behavior, and (4) the core separation into two thermal-hydraulically different regions and the in-core flow ...
1983-12-13
Protein expression in white spot syndrome virus infected Penaeus monodon fabricius.
White spot syndrome virus (WSSV) is the causative agent of the white spot disease of shrimp. Penaeus monodon were captured from Muttukadu Estuary in Chennai, India, transported to the laboratory and maintained in an aerated system with continuous water circulation-biofiltration. WSSV-free P. monodon were challenged by feeding them only once with WSSV-infected tissues of P. monodon. Cumulative mortality (100%) of the infected individuals was determined. Tissues from infected and uninfected shrimp such as muscles, hepatopancreas, heart, gills and eye tissues (100mg of each) and haemolymph (50 microl) were subjected to SDS-PAGE. In infected muscle tissue, six newly expressed proteins were detected. In infected haemolymph, four new proteins and three intensely expressed high molecular weight proteins were observed. Three intensely expressed high molecular weight proteins were detected in infected heart tissue and two new proteins in infected ...
2005-06-01
Heat transfer augmentation through wall-shape-induced flow destabilization
Energy Technology Data Exchange (ETDEWEB)
Experiments on heat transfer augmentation in a rectangular cross-section water channel are reported. The channel geometry is designed to excite normally damped Tollmein-Schlichting modes in order to enhance mixing. In this experiment, a hydrodynamically fully developed flow encounters a test section where one channel boundary is a series of periodic, saw-tooth, transverse grooves. Free shear layers span the groove openings, separating the main channel flow from the circulating vortices contained within each cavity. The periodicity length of the grooves is equal to one-half of the expected wavelength of the most unstable mode. The remaining channel walls are flat, and the channel has an aspect ratio of 10:1. Experiments are performed over the Reynolds number range of 300 to 15,000. Streakline flow visualization shows that the flow is steady at the entrance, but becomes oscillatory downstream of an onset location. This location moves upstream ...
1990-05-01
Global changes and the air-sea exchange of chemicals
International Nuclear Information System (INIS)
Present and potential future changes to the global environment have important implications for marine pollution and for the air-sea exchange of both anthropogenic and natural substances. This report addresses three issues related to the potential impact of global change on the air-sea exchange of chemicals: Global change and the air-sea transfer of the nutrients nitrogen and iron. Global change and the air-sea exchange of gases. Oceanic responses to radiative and oxidative changes in the atmosphere. The deposition of atmospheric anthropogenic nitrogen has probably increased biological productivity in coastal regions along many continental margins. Atmospheric deposition of new nitrogen may also have increased productivity somewhat in mid-ocean regions. The projected future increases of nitrogen oxide emissions from Asia, Africa and South America will provide significant increases in the rate of deposition of oxidized nitrogen to the central North Pacific, the equatorial Atlantic, and ...
1996-08-01
Foreign wood fuel supply for power generation in the Netherlands. Final report
Energy Technology Data Exchange (ETDEWEB)
In the Netherlands, the interest in biomass for electricity generation has increased, mainly due to environmental reasons. Currently, the Dutch energy sector is investigating technologies which can reduce CO{sub 2} emissions. The growth of biomass and its subsequent utilization for energy purposes circulates recycled atmospheric carbon and has no net discharge of CO{sub 2}. To reduce emissions from coal-fired power plants biomass co-firing options are investigated. After exhaustion of internal supplies of wood wastes and other residues an extra amount of 1.02 Mt{sub 20} would be needed. Two supply options exist: the use of internal energy crops and the import of biomass. Because production of energy crops in the Netherlands is a rather expensive option, biomass procurement and production outside the Netherlands is studied. Two countries were investigated for the possible import of biomass: Estonia and Uruguay. Estonia has short-term opportunities for residue supply ...
1995-08-01
Energy Technology Data Exchange (ETDEWEB)
The feasibility study was conducted on a model project in Vietnam, aimed at solving the environmental pollution problems resulting from use of coal by demonstrating and disseminating the Japan's environmental technologies in the Southeast Asian countries. The feasibility study was conducted for the Cua Ong Coal Preparation Enterprise, which has the largest coal preparation capacity in Vietnam and port facilities. It is treating raw coal from 10 coal mines for classification and preparation, and shipping coal of various types that meet the standards for domestic use and export. The survey results point out that unrecovered coal remains in waste water discharged from the coal preparation plants to pollute the sea area, and that quantity of the refuse increases because of the unrecovered coal it contains. The environmental technologies needed to introduce include modification to variable wave pattern type jigging separator, refuse height measuring instrument ...
2001-06-01
Water Quality and 401 Certification | Clean Water Act | US EPA
Clean Water Act You are here: Water Laws & Regulations Policy & Guidance Clean Water Act Water Quality and 401 Certification Water Quality and 401 Certification Water Quality...
2011-08-28
Energy Technology Data Exchange (ETDEWEB)
The paper gives an overview on the technologies and applications of automatic wood furnaces. The combustion systems are defined by the flow condition: With increasing gas velocity, fixed bed, stationary fluidized bed (SFB), circulating fluidized bed (CFB), and entrained flow reactors are distinguished. The furnace design and typical applications are described. Further, a comparison is presented which gives data of the typical size range and fuel types for the different combustion systems. The most common fixed bed reactors are under-stoker and grate furnaces. While under-stoker furnaces are applied in the size range from 20 kW to 2.5 MW, grate furnaces cover the size range from a few 100 kW up to more than 50 MW. Under-stoker furnaces are well suited for wood fuel with low ash content, moderate water content and limited fuel size. Grate furnaces are also suited for fuel with high ash and water content and large fuel sizes. ...
2001-07-01
Energy Technology Data Exchange (ETDEWEB)
This report is to present the progress made on the project ''Establishment of an Environmental Control Technology Laboratory (ECTL) with a Circulating Fluidized-Bed Combustion (CFBC) System'' during the period October 1, 2004 through December 31, 2004. The following tasks have been completed. First, the renovation of the new Combustion Laboratory and the construction of the Circulating Fluidized-Bed (CFB) Combustor Building have proceeded well. Second, the detailed design of supporting and hanging structures for the CFBC was completed. Third, the laboratory-scale simulated fluidized-bed facility was modified after completing a series of pretests. The two problems identified during the pretest were solved. Fourth, the carbonization of chicken waste and coal was investigated in a tube furnace and a Thermogravimetric Analyzer (TGA). The experimental results from this study are presented in this report. Finally, ...
2005-01-30
Energy Technology Data Exchange (ETDEWEB)
This report is to present the progress made on the project ''Establishment of an Environmental Control Technology Laboratory (ECTL) with a Circulating Fluidized-Bed Combustion (CFBC) System'' during the period July 1, 2004 through September 30, 2004. The following tasks have been completed. First, renovation of the new Combustion Laboratory and the construction of the Circulating Fluidized-Bed (CFB) Combustor Building have started. Second, the design if the component parts of the CFBC system have been reviewed and finalized so that the drawings may be released to the manufacturers during the next quarter. Third, the experiments for solid waste (chicken litter) incineration have been conducted using a Thermogravimetric Analyzer (TGA). This is in preparation for testing in the simulated fluidized-bed combustor. The experimental results from this study are presented in this report. Finally, the proposed work for ...
2004-10-30
Energy Technology Data Exchange (ETDEWEB)
Natural circulation experiments carried out in the REWET-III facility in 1985 have been used for RELAP5/MOD2 assessment. The REWET-III facility is a scaled-down model of VVER-440 type reactors. The facility consists of a pressure vessel in which the downcomer is simulated with an external pipe assembly, hot and cold legs with loop seals and a horizontal steam generator. The volume scaling factor compared to the reference reactor is 1:2333. The present paper summarizes the experiences gained in the RELAP5/MOD2 calculations of selected REWET-III single- and two-phase natural circulation experiments. The code's ability to represent the main phenomena of experiments in both cases was satisfactory.
1992-04-01
Energy Technology Data Exchange (ETDEWEB)
Natural circulation experiments carried out in the REWET-III facility in 1985 have been used for RELAP5/MOD2 assessment. The REWET-III facility is a scaled-down model of VVER-440 type reactors. The facility consists of a pressure vessel in which the downcomer is simulated with an external pipe assembly, hot and cold legs with loop seals and a horizontal steam generator. The volume scaling factor compared to the reference reactor is 1:2333. The present paper summarizes the experiences gained in the RELAP5/MOD2 calculations of selected REWET-III single- and two-phase natural circulation experiments. The code`s ability to represent the main phenomena of experiments in both cases was satisfactory.
1992-04-01
International Nuclear Information System (INIS)
Natural circulation experiments carried out in the REWET-III facility in 1985 have been used for RELAP5/MOD2 assessment. The REWET-III facility is a scaled-down model of VVER-440 type reactors. The facility consists of a pressure vessel in which the downcomer is simulated with an external pipe assembly, hot and cold legs with loop seals and a horizontal steam generator. The volume scaling factor compared to the reference reactor is 1:2333. The present paper summarizes the experiences gained in the RELAP5/MOD2 calculations of selected REWET-III single- and two-phase natural circulation experiments. The code's ability to represent the main phenomena of experiments in both cases was satisfactory.
1992-01-01
An investigation of the thermal performance of an oil filled transformer winding
Energy Technology Data Exchange (ETDEWEB)
Manufacturers may be required to design transformers to overload specifications. Oil viscosity changes and loss variation with temperature are not accounted for in the industry loading guide. A comprehensive test program was performed using a winding assembly with imbedded thermocouples. Steady state and transient tests were performed for natural and non-directed forced oil circulation. The temperature distribution in the winding was not linear with height as usually assumed. A large number of temperature sensors is required to determine the hot spot location. The location of the hot spot was found to be different and less predictable for natural oil circulation compared with non-directed forced oil circulation especially during overload conditions. This paper reports that improved loading guide equations were developed to account for oil viscosity, resistance change, cooling duct oil rise, and location of the hot spot.
1992-07-01
International Nuclear Information System (INIS)
Ground-source heat pump systems (GSHPSs), also referred to as geothermal heat pump systems (GHPSs), have been widely used in residential and commercial buildings for years due to their outstanding energy utilization efficiencies. In this study, an energy and exergy modeling of solar assisted ground-source heat pump systems for residential applications is presented for system analysis and performance evaluation. In this regard, the performance of a solar assisted ground-source heat pump heating system, installed in Solar Energy Institute of Ege University, Izmir, Turkey, is evaluated based on the actual operational data to show how energy and exergy efficiencies values change with the system. The average heating coefficient of performances (as energy efficiencies) of the solar assisted ground-source heat pump (GSHP) unit and the overall system are obtained to be 2.64 and 2.38, ...
2005-06-12
Energy Technology Data Exchange (ETDEWEB)
One of the principal problems confronting the remediation of Bear Creek Valley is the cleanup of contaminated groundwater. The S-3 Site is one of the locations in the valley where groundwater is most contaminated, and contamination from the S-3 Site has also caused extensive contamination of downgradient groundwater. This groundwater plume, therefore, has a high priority in the Bear Creek Valley remedial process. Pumping and treating groundwater was identified early in the feasibility study as a likely remedial alternative for the S-3 Site groundwater plume. The hydrology and geochemistry of the plume are extremely complex. There is a high degree of uncertainty in the current understanding of how the aquifer will react physically and chemically to pumping, making evaluation of a pump-and-treat alternative impractical at the present time. Before a pump-and-treat alternative can be evaluated, its ...
1995-02-01
An accurate high-speed single-electron quantum dot pump
International Nuclear Information System (INIS)
Using standard microfabrication techniques, it is now possible to construct devices that appear to reliably manipulate electrons one at a time. These devices have potential use as building blocks in quantum computing devices, or as a standard of electrical current derived only from a frequency and the fundamental charge. To date, the error rate in semiconductor 'tuneable-barrier' pump devices, those which show most promise for high-frequency operation, have not been tested in detail. We present high-accuracy measurements of the current from an etched GaAs quantum dot pump, operated at zero source-drain bias voltage with a single ac-modulated gate at 340 MHz driving the pump cycle. By comparison with a reference current derived from primary standards, we show that the electron transfer accuracy is better than 15 parts per million. High-resolution studies of the dependence of the pump current on the ...
2010-07-01
International Nuclear Information System (INIS)
This paper presents a novel organization of switch capacitor charge pump circuits based on voltage doubler structures. Each voltage doubler takes a DC input and outputs a doubled DC voltage. By cascading voltage doublers the output voltage increases up to 2 times. A two-phase voltage doubler and a multiphase voltage doubler structures are discussed and design considerations are presented. A simulator working in the Q-V realm was used for simplified circuit level simulation. In order to evaluate the power delivered by a charge pump, a resistive load is attached to the output of the charge pump and an equivalent capacitance is evaluated. To avoid the short circuit during switching, a clock pair generator is used to achieve multi-phase non-overlapping clock pairs. This paper also identifies optimum loading conditions for different configurations of the charge pumps. The proposed ...
2010-04-01
Snow Survey & Water Supply | NRCS
Programs & Services Technical Resources Land Use Soils Water Snow Survey & Water Supply Water Management Water Quality Watersheds Wetlands Air Plants & Animals Energy Climate...
2011-08-21
Static frequency converters for adjustable-speed sets
Energy Technology Data Exchange (ETDEWEB)
Recent research work on adjustable speed pumped storage plants conducted in Japan, the USA and Europe suggests that they have many advantages over fixed-speed plants, and can contribute to power system regulation even in pump mode. This paper describes two types of static frequency converter for such pumped storage plants, especially those with greatly fluctuating heads. The design characteristics and operation of the doubly fed induction machine and the synchronous machine with DC link converter are set out and the devices compared. (UK)
1995-06-01
Replacement of bearing journals on heat transport pumps at the Wolsung nuclear generating station
International Nuclear Information System (INIS)
The major details of the inspection and replacement of the bearing journals on each of the four heat transport pumps (HTPs) at Wolsung nuclear generating station in Korea are presented in this paper. Investigation following fracture of one of the journals in 1985 revealed that it was excessively hard. The journal material (ASTM A296 CA 40) is considered to be prone to stress corrosion fatigue if the hardness exceeds Rc 40. In 1986 May, during a planned outage, the HTPs were disassembled, the journals were inspected, found to be excessively hard, and all were replaced. At the same time, the pump to motor couplings were all refurbished to ensure proper alignment.
1987-11-22
Pumped storage plants. Status and perspectives
Energy Technology Data Exchange (ETDEWEB)
Pumped storage plants (PSP) enable the storage of energy with rated capacities of order of GW at a single site. Reservoirs allow charging and discharging times of at least hours, sometimes days or even up to several weeks. Short ramp-up times permit the participation in the secondary reserve market as a standing reserve. For bulk energy storage, PSP reach the lowest, specific costs. In the EU27 countries, Norway and Switzerland, a total of 44 GW of pumped storage capacity is installed. The utilisation of PSP strongly correlates with the amount of conventional generation capacity, rather than with topographical options. (orig.)
2011-07-01
Pumped storage plants in a new framework - challenges and consequences
Energy Technology Data Exchange (ETDEWEB)
Originally designed exclusively for peak load covering, pumped storage plants are now faced with new challenges brought about by the deregulation of the electricity market and the substantial growth of wind power capacity. Today's pumped storage plants are started more frequently and often for shorter periods of time. The grid controlling tasks have increased the importance of the role played by this type of power plant and improved sales considerably. But the operational demands have grown substantially as well. This paper discusses the ensuing adaptation of power plant operation as well as options available to power plant operators. (orig.)
2006-07-01
Production of polarized negative ion beams by collisional pumping
Energy Technology Data Exchange (ETDEWEB)
The production of polarized negative ion beams by collisional pumping is described. Collisional pumping utilizes repeated charge changing collisions in a thick electron-spin-polarized gas or vapor target to form a polarized fast atom beam. The polarized fast atom beam is then partially converted into a polarized negative ion beam in a vapor target. Analysis is presented for a hydrogen beam passing through either a thick polarized H atom target or a thick polarized alkali target. Large polarizations and large currents may be possible.
1983-01-01
Production of polarized negative ion beams by ''collisional pumping''
Energy Technology Data Exchange (ETDEWEB)
The production of polarized negative ion beams by ''collisional pumping'' is described. Collisional pumping utilizes repeated charge changing collisions in a thick electron-spin-polarized gas or vapor target to form a polarized fast atom beam. The polarized fast atom beam is then partially converted into a polarized negative ion beam in a vapor target. Analysis is presented for a hydrogen beam passing through either a thick polarized H atom target or a thick polarized alkali target. Large polarizations and large currents may be possible.
1984-03-01
Large scale breeder reactor pump dynamic analyses
Energy Technology Data Exchange (ETDEWEB)
The lateral natural frequency and vibration response analyses of the Large Scale Breeder Reactor (LSBR) primary pump were performed as part of the total dynamic analysis effort to obtain the fabrication release. The special features of pump modeling are outlined in this paper. The analysis clearly demonstrates the method of increasing the system natural frequency by reducing the generalized mass without significantly changing the generalized stiffness of the structure. Also, a method of computing the maximum relative and absolute steady state responses and associated phase angles at given locations is provided. This type of information is very helpful in generating response versus frequency and phase angle versus frequency plots.
1982-01-01
Geothermal heat pump performance and utility programs in the United States
Energy Technology Data Exchange (ETDEWEB)
Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past 10 years in the United States. These systems offer substantial benefits to consumers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data were available mainly from electric utilities on heat pump performance, energy savings, and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market entry, incentive programs, and benefits.
1997-01-01
Geothermal heat pump performance
Energy Technology Data Exchange (ETDEWEB)
Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to customers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market penetration, incentive programs, and benefits.
1995-12-31
Energy Technology Data Exchange (ETDEWEB)
As an application of ART2 neural networks, computer aided monitoring of pump efficiency is successfully examined for an industrial waste-liquid treatment process with measured data of valve openness and liquid flow rates. By running the neural networks in parallel, we confirm that accuracy to detect system changes is good, and the adjustment of classifier parameters is relatively easy. Investigating the resulting classes carefully, frequency of each class is correlated with pump efficiency. The relative amount of variables are also related to the classes. (author)
2000-05-10
Application aspects of the static frequency converter system
Energy Technology Data Exchange (ETDEWEB)
The use of reversible pump/turbine sets in pumped storage has created a requirement for rapid reversibility. Softstart technology, based on static frequency converters (SFC) has evolved to such an extent that it is now the best choice for serving this purpose, both from a technical and from an economic point of view. The objective of our paper is to give the owners of pumped storage plants and those persons responsible for the selection, the operation or the maintenance of the electrical equipment the necessary insight into the SFC functions, features and all other application related aspects, to facilitate their decision making process. Case studies are included.
1995-12-31
An algorithm for scheduling a large pumped storage plant
Energy Technology Data Exchange (ETDEWEB)
The Michigan Electric Coordination Center (MEPCC), operated by Consumers Power and Detroit Edison Companies, has the responsibility for scheduling the Ludington pumped storage plant. Ludington has an extremely large economic effect on the Consumers Power and Detroit Edison Companies' system due to its size (over 1800 MW net demonstrated generating capability). This paper presents a dynamic programming algorithm for scheduling large pumped storage plants and shows how this method can be coordinated with the commitment of the thermal units of the system.
1985-08-01
Theoretical analysis of the DC electromagnetic flow coupler
Energy Technology Data Exchange (ETDEWEB)
A descriptive model and design procedure for the DC electromagnetic flow coupler is developed based on a quasi-one-dimensional analysis previously developed for the DC electromagnetic pump. It is shown that for a particular flow coupler geometry, the total efficiency and the pressure gradients through the pump and generator depend on two parameters - the Hartmann number and the ratio of the pump flow rate to generator flow rate. Thus, for a fixed Hartmann number the efficiency depends only on the flow ratio. However, for a fixed pressure rise through the pump it is shown that the efficiency depends only on the Hartmann number. Nomographs showing the operating characteristics and critical design points are presented. Example calculations for a full-size unit, suitable for use in a liquid-metal cooled fast breeder reactor, are also discussed using the design nomographs.
1983-03-01
Energy Technology Data Exchange (ETDEWEB)
This comprehensive final report for the Swiss Federal Office of Energy (SFOE) presents the results of research done in the third phase of a research project that investigated components for small heat pump systems that use ammonia as a working fluid. The report includes a summary of the findings of the first two phases of the project and goes on to describe tests done with rotary vane and scroll compressors. The aims of the project are discussed and the work done is listed chronologically. The construction and the components of the test installation are described in detail. Also, the heat pump testing facilities at the University of Applied Science in Rapperswil, Switzerland, are described. The results of the measurements made for various temperature gradients are presented in detail and commented on; also, the various types of compressor tested and other heat pump compressors are compared.
2003-07-01
Refilling Intracellular Calcium Stores
UK PubMed Central (United Kingdom)
Within the cardiac cell, the movements of calcium ions are tightly regulated by a number of regulatory proteins including pumps, and channels. The sarcoplasmic reticulum (SR) is in large part...Full Text Available
2010-01-01
... B. P. Rosen. An arsenic metallochaperone for an arsenic detoxification pump. Proc. Natl. Acad. Sci. U. S. A 103( ... ...
International Nuclear Information System (INIS)
... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,
2006-09-11
Operation and maintenance experiences of pumped-storage plants
Energy Technology Data Exchange (ETDEWEB)
This report presents the results of a study on Operation and Maintenance (O M) practices in hydroelectric pumped storage plants. The objective of this project, which was sponsored by EPRI, is to record the practical knowledge on the O M of a number of the domestic and foreign pumped storage plants which has been accumulated by their operating staff. Civil, geotechnical, mechanical and electrical aspects of O M of the thirty-five plants visited are discussed, and some general conclusions, as warranted by the commonality of the problems, are drawn. These conclusions may be useful to the planners and designers of future pumped storage projects. In general, due to their layout, diversity and different modes of operation, the plants have few common problems which, in most cases, are limited to the mechanical and electrical aspects of the plants' operation. The data on plants' specifications, operation and ...
1991-05-01
Ion channels, transporters, and pumps as targets for heart failure
UK PubMed Central (United Kingdom)
Congestive heart failure (CHF) is a leading cause of morbidity and mortality. CHF is marked by atrial and ventricular enlargement and reduced cardiac contractility, as well as an association...Full Text Available
2009-10-01
Extraction of biologic particles by pumping effect in a p-shaped ultrasonic actuator
British Library Electronic Table of Contents (United Kingdom)
This paper presents a new method of extracting biologic particles from a mixture of particles. The method is based on the pumping effect in a p-shaped ultrasonic actuator, which has a gap between its two vibrating metal plates. An adhesive tape is placed at a proper position in the gap. Due to the pumping effect which is induced by the sound field in the gap, the particles with smaller mass and radius in the mixture can be pumped up to reach the adhesive tape; while the ones with larger mass cannot. Therefore, the particles with smaller mass and radius can be extracted from the mixture. A theoretical model which can well explain the operation principle and experimental phenomena is developed. By the experimental results and the theoretical analyses based on the model, the validity of the m...
2006-01-01
Effect of vanadate on proton-sucrose cotransport in Ricinus cotyledons
Energy Technology Data Exchange (ETDEWEB)
The effects of orthovanadate on the uptake of sucrose by Ricinus cotyledons and on sucrose-coupled proton influx were measured in order to gain insight into the relationship to the plasma membrane proton pump. Vanadate had no effect on short-term sucrose uptake. In long-term experiments (> 30 min) sucrose uptake was progressively inhibited, but only at high external sucrose concentrations. Vanadate did not affect proton efflux pumping in the absence of sucrose and neither did it change the initial rate of sucrose-coupled proton influx. However, it enhanced the maximal level of sucrose-induced alkalization of the medium at all sucrose concentrations tested. This is interpreted as an inhibiting effect of vanadate on the proton pump that recycles protons during sucrose-proton cotransport. The sensitivity towards vanadate indicates that this proton pump is an ATPase. A second proton-translocating system, ...
1987-07-01
Cooperative Effects on Transient Spectral Hole Burning
... of Dist SpeA tI/ __LLL5' Page 5. 3 the coherent effects on the spontaneous radiation, we calculate the pump- field-induced ...
1992-06-01
An arsenic metallochaperone for an arsenic detoxification pump
UK PubMed Central (United Kingdom)
Environmental arsenic is a world-wide health issue, making it imperative for us to understand mechanisms of metalloid uptake and detoxification. The predominant intracellular form is the highly mephitic...Full Text Available
2006-10-17
A pump-probe XFEL particle injector for hydrated samples
We have developed a liquid jet injector system that can be used for hydrated sample delivery at X-ray Free Electron Laser (XFEL) sources and 3rd generation synchrotron sources. The injector is based on the Gas Dynamic Virtual Nozzle (GDVN), which generates a liquid jet with diameter ranging from 300 nm to 20 {\\mu}m without the clogging problems associated with conventional Rayleigh jets. An improved nozzle design is presented here. A differential pumping system protects the vacuum chamber and an in-vacuum microscope allows observation of the liquid jet for diagnostics while it is being exposed to the X-ray beam. A fiber optically coupled pump laser illuminating the jet is incorporated for pump-probe experiments. First results with this injector system have been obtained at the LCLS.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
An exergoeconomic model of a vertical ground-source heat pump residential heating system presented in this study uses exergy and cost energy mass (EXCEM) methods. The data obtained from a ground-source heat pump (GSHP) residential heating system installed at the Solar Energy Institute, Ege University, Turkey, are utilized for calculations at different reference temperature values in the range 0-25{sup o}C. The performance of the geothermal heat pump residential heating system is evaluated to indicate how exergoeconomic parameter values change with system. We also undertake a parametric study to investigate how varying reference temperatures will affect the exergoeconomic analysis of the GSHP system. A correlation between the ratio of thermodynamic loss rate to capital cost and reference state temperature is developed. (author)
2007-03-15
A comparison of convenience features for Japanese and American residential heat pumps
Energy Technology Data Exchange (ETDEWEB)
The fundamental differences in the type of products sold in both Japan and the US, and some of the reasons for these differences, are outlined. Japan is the largest single country market for residential heat pumps, while the US represents the largest single country market for residential heating equipment. Quite different types and associated features of heat pumps are demanded in the USA and Japan. The term `convenience features`, used to describe the physical characteristics of the user interface device, is explained, as well as the fundamental reasons leading to the particular styles of product sold in each country: (1) product strategy and sales channels, (2) design of housing, (3) climatic factors, and (4) energy costs and distribution. It is stressed that there is no big cooling load in Japan. It is rather the comfort issue that drives the market for heat pumps
1996-07-01
WorId Ocean Circulation Experiment - OceanESIP - NASA
period T. Also shown is the returned chirp from a specular reflector at ...... algorithms is a Brown (1977) model of the return waveform, which assumes a ...... Townsend, W.F., 1980: An initial assessment of the performance achieved by ...
UK PubMed Central (United Kingdom)
BackgroundAntioxidant vitamins are often described as having “independent” associations with risk of cancer, cardiovascular disease (CVD) and mortality. We aimed...Full Text Available
Thermal energy considerations on solar cavity wall building
Energy Technology Data Exchange (ETDEWEB)
The dwelling is equipped with solar collectors which heat the air circulating in the cavity walls and the space beneath the floors. The thermal aspects of such a building are described. Heat balance, losses, heating by the sun in different seasons are described. Different measures taken to reduce the energy losses are described.
1983-02-01
UK PubMed Central (United Kingdom)
BackgroundInflammatory markers may be associated with recurrent vascular events after stroke. We aimed to: (1) determine the association between interleukin-6, C-reactive...Full Text Available
2011-01-01
The Vasoactive Potential of Kisspeptin-10 in the Peripheral Vasculature
UK PubMed Central (United Kingdom)
Splice products of the Kiss1 protein (kisspeptins) have been shown to be involved in a diverse range of functions, including puberty, metastasis and vasoconstriction in large human arteries. Circulating...Full Text Available
Spread of a highly mucoid Streptococcus pyogenes emm3/ST15 clone
UK PubMed Central (United Kingdom)
BackgroundHyaluronic acid capsule plays a key role in Streptococcus pyogenes virulence. Circulation of mucoid or highly encapsulated strains has been related to...Full Text Available
UK PubMed Central (United Kingdom)
BackgroundTransarterial chemoembolization (TACE) therapy is an effective locoregional treatment in hepatocellular cancer (HCC) patients. For early modification of therapy, markers...Full Text Available
Plan and justification for a Proof-of-Concept oil shale facility. Final report
Energy Technology Data Exchange (ETDEWEB)
The technology being evaluated is the Modified In-Situ (MIS) retorting process for raw shale oil production, combined with a Circulating Fluidized Bed Combustor (CFBC), for the recovery of energy from the mined shale. (VC)
1990-12-01
Plan and justification for a Proof-of-Concept oil shale facility
Energy Technology Data Exchange (ETDEWEB)
The technology being evaluated is the Modified In-Situ (MIS) retorting process for raw shale oil production, combined with a Circulating Fluidized Bed Combustor (CFBC), for the recovery of energy from the mined shale. (VC)
1990-12-01
Optimal bone strength and mineralization requires the type 2 iodothyronine deiodinase in osteoblasts
UK PubMed Central (United Kingdom)
Hypothyroidism and thyrotoxicosis are each associated with an increased risk of fracture. Although thyroxine (T4) is the predominant circulating thyroid hormone, target cell responses are determined...Full Text Available
2010-04-20
International Nuclear Information System (INIS)
The natural circulation experiments were conducted to confirm the cooling capability and the flow characteristics of the natural convection in the HANARO (Hi-flux Advanced Neutron Application Reactor). The tests were done at the power levels of 2%, 3% and 4% (1.2MW_t_h) of full power. The flow rates and temperatures at various locations of the primary and secondary cooling loops were measured at each power level. The temperature distributions in the chimney and the pool were also obtained. Through tests, the flow paths of the natural circulation and the cooling capability of the reactor were confirmed as designed. In addition, the simulation for the natural circulation tests was made by using RELAP5/KMRR, which was modified from RELAP5/MOD2 for applying to the HANARO conditions. The simulation results show that RELAP5/KMRR gives reasonable predictions for the flow rate and the coolant temperature during natural ...
On the Uptake of Materials by the Intact Liver. THE TRANSPORT AND NET REMOVAL OF GALACTOSE
UK PubMed Central (United Kingdom)
D-galactose, a monosaccharide rapidly phosphorylated within liver cells, is irreversibly removed from the portal circulation. We have studied the kinetic relations between the hepatic cell entry process...Full Text Available
1973-05-01
UK PubMed Central (United Kingdom)
BackgroundHepatitis A virus (HAV) strains detected in environmental and clinical samples were analysed to characterize the genotypes of HAV circulating in Greece. Fifty (50) sewage...Full Text Available
UK PubMed Central (United Kingdom)
Neuropilin-1 (NRP1) acts as a co-receptor for class 3 semaphorins and vascular endothelial growth factor and is an attractive angiogenesis target for cancer therapy. In addition to the transmembrane...Full Text Available
2009-07-01
UK PubMed Central (United Kingdom)
Acute myocardial infarction (AMI) is a common cause of death for which effective treatments are available provided that diagnosis is rapid. The current diagnostic gold standards are circulating cardiac...Full Text Available
2009-12-01
UK PubMed Central (United Kingdom)
AbstractMultiple HIV-1 subtypes and circulating recombinant forms (CRFs) are known to cocirculate in Africa. In West Africa, the high prevalence of CRF02_AG, and cocirculation of subtype...Full Text Available
2009-01-01
UK PubMed Central (United Kingdom)
BackgroundThe objective of the study was to analyse the evolution of Bordetella pertussis population and the influence of herd immunity in different areas of the...Full Text Available
UK PubMed Central (United Kingdom)
The presence of DNA-anti-DNA complexes in sera from patients with systemic lupus erythematosus (SLE) was investigated by two new radioimmunoassays (RIA) developed for this purpose and by measuring the...Full Text Available
1977-12-01
Endemic Circulation of European Bat Lyssavirus Type 1 in Serotine Bats, Spain
UK PubMed Central (United Kingdom)
To determine the presence of European bat lyssavirus type 1 in southern Spain, we studied 19 colonies of serotine bats (Eptesicus isabellinus), its main reservoir, during 1998–2003....Full Text Available
2008-08-01
UK PubMed Central (United Kingdom)
The objective of this work was to evaluate the physical properties and in vivo circulation of chitosan (CH)-coated liposomes of mitoxantrone (MTO). Changes in particle size and zeta...Full Text Available
2010-01-01
UK PubMed Central (United Kingdom)
Japanese medaka (Oryzias latipes) embryos exposed to ethanol have developed craniofacial, cardiovascular and skeletal defects which can be compared with the phenotypic features...Full Text Available
2008-09-01
Energy Technology Data Exchange (ETDEWEB)
The circulation in microvascularized rib grafts has been compared with that in conventional rib grafts and in those augmented by a direct vascular bundle implantation into the bone grafts. A new experimental model has been designed to correlate vascular perfusion, bone scan patterns, tetracycline labeling, and histological findings in these bone grafts. Posterior microvascularized rib grafts were found to have a circulatory pattern identical to that of the normal rib. Failed microvascularized rib grafts were revascularized more slowly than conventional rib grafts. Vascular bundles implanted into rib grafts remained patent and increased the rate of revascularization. The stripping or preservation of periosteum had no observable effects on the rate or pattern of conventional rib graft revascularization. The circulation in rib grafts was accurately reflected in technetium 99 bone scans, as was the patency of the anastomoses of microvascularized ...
1984-11-01
UK PubMed Central (United Kingdom)
Sera from multiple sclerosis patients with relapsing-remitting disease and normal subjects were tested for antibody to myelin basic protein by a sensitive radioimmunoassay. The results showed a marginally...Full Text Available
1978-12-01
UK PubMed Central (United Kingdom)
BackgroundEmbolic events (EE) in infective endocarditis (IE) are caused by fragmentation of vegetations or valvular tissue. Vegetation length is considered to be the most potent...Full Text Available
Basilar artery aneurysm with autonomic features: an interesting pathophysiological problem
UK PubMed Central (United Kingdom)
Unruptured cerebral aneurysms often present with neuro-ophthalmological symptoms but ocular autonomic involvement from an aneurysm of the posterior circulation has not previously been reported. A patient...Full Text Available
2001-12-01
Anti-Apoptotic Genes in the Survival of Monocytic Cells During Infection
UK PubMed Central (United Kingdom)
Macrophages are cells of the immune system that protect organisms against invading pathogens by fulfilling critical roles in innate and adaptive immunity and inflammation. They originate from circulating...Full Text Available
2009-08-01
A rapidly hydrated sorbent for moderate-temperature dry flue gas desulfurization was prepared by rapidly hydrating adhesive carrier particles and lime. The circulation ash from a circulating fluidized bed boiler and chain boiler ash, both of which have rough surfaces with large specific surface areas and specific pore volumes, can improve the adhesion, abrasion resistance, and desulfurization characteristics of rapidly hydrated sorbent when used as the adhesive carrier particles. The adhesion ability of sorbent made from circulation ash is 67.4% higher than that of the existing rapidly hydrated sorbent made from fly ash, the abrasion ratio is 76.2% lower, and desulfurization ability is 14.1% higher. For sorbent made from chain boiler ash, the adhesion ability is increased by 74.7%, the desulfurization ability is increased by 30.3%, and abrasion ratio is decreased by 52.4%. The abrasion ratios of the sorbent made from ...
2010-06-15
UK PubMed Central (United Kingdom)
Platelet Factor VIII-related antigen (VIIIR:Ag) represents a significant proportion of the total circulating VIIIR:Ag pool. However, its participation in the events of primary hemostasis has not been...Full Text Available
1978-12-01
A direct role for serum albumin in the cellular uptake of long-chain fatty acids.
UK PubMed Central (United Kingdom)
The interaction of long-chain fatty acids with cells is important for their uptake and metabolism, as well as their involvement in signalling processes. The majority of long-chain fatty acids circulating...Full Text Available
1995-05-15
Pansystems traffics, logistics and knowledge rediscovery
British Library Electronic Table of Contents (United Kingdom)
Purpose - The purpose of this paper is to develop pansystems-styled traffics, logistics and knowledge rediscovery. The core logoi are the generalized resources//F* and their circulation//C*. The research presents a new outlook to mathematics, physics, traffic, communication, logistics, KD, internet, computer, translation, simulation, information, life-systems, logic or reasoning, memory or storage, process, transaction, finance, education, inherent, topology, evolution, etc. and then certain mechanism among them and related mutuality can be unveiled. Design/methodology/approach - A flexible combination of philosophy, mathematics and technology is embodied. The paper is an application of pansystems methodology to approach the following topics: pansystems resource, circulation: traffics, log...
2009-01-01
In vitro and in vivo analysis of pegulated Avidin
Energy Technology Data Exchange (ETDEWEB)
Full text: In 1995, we demonstrated the use of pretargetting three steps method and biotinylated tetracycline using radiolabelled {sup 99m}Tc-DTPA-biocytinamide for the detection of tumour cells in (C57B1/6 x BALB/C) F1 mice with E-3 thymoma. The three steps were (1) IP injection of biotinylated-tetracycline conjugate (1:1) ratio, (2) 96 hours later Avidin/Streptavidin was injected, and (3) 24 hours after (2), {sup 99m}Tc-biocytinamide -cDTPA was injected. Mice were sacrificed 16/24 h after (3) by cervical dislocation. Biodistribution of radioactivity tumour to blood, liver, bone were T:B1= 15.0, T:Li= 5.08, T:Bo=15.0. The percentage of injected dose per g was T= 3.15% and B1= 0.21%. To prolong circulation of Avidin and therefore its uptake into tumour, Avidin was covalently bound to polyethylene-glycol (PEG20 KD) at the molar ratio of PEG:Avidin 100:1 and 400:1. The pegulated Avidin was then cleared from the circulation using ...
1997-09-01
Development of Synthol circulating fluidized bed reactors
Energy Technology Data Exchange (ETDEWEB)
In 1980 Sasol completed its very large coal conversion complex, Sasol Two and Three in South Africa. This complex, the largest coal-to-liquids facility in the world, utilizes Sasol's proprietary Fischer-Tropsch technology, the Synthol Process. The two key elements of the Synthol Process are its catalyst and its unique fluidized bed reactor, the Synthol Circulating Fluidized Bed Reactor. Details on the catalytic aspects and reaction mechanism have been given elsewhere. In this paper, the history of the development of the reactor is discussed.
1986-08-01
CIRNAT - a code for one and two-phase natural circulation
Energy Technology Data Exchange (ETDEWEB)
CIRNAT, a one-dimensional code for natural circulation analysis, was described. The homogeneous approach was adopted for the two-phase flow regime and different heat transfer regimes were considered. The code was exhaustively tested for one-phase flow systems. For two phase flows a boiling/condensing system was simulated. The results are qualitatively correct but the oscillations observed at the system were not captured by the model. Other two-phase flow tests must be done to show the limits of the homogeneous approach before the introduction of a more complex model. (author)
1996-07-01
CIRNAT - a code for one and two-phase natural circulation
International Nuclear Information System (INIS)
CIRNAT, a one-dimensional code for natural circulation analysis, was described. The homogeneous approach was adopted for the two-phase flow regime and different heat transfer regimes were considered. The code was exhaustively tested for one-phase flow systems. For two phase flows a boiling/condensing system was simulated. The results are qualitatively correct but the oscillations observed at the system were not captured by the model. Other two-phase flow tests must be done to show the limits of the homogeneous approach before the introduction of a more complex model. (author)
1996-11-11
Performance assessment for the disposal of low-level waste in the 200 east area burial grounds
Energy Technology Data Exchange (ETDEWEB)
A performance assessment analysis was completed for the 200 East Area Low-Level Burial Grounds (LLBG) to satisfy compliance requirements in DOE Order 5820.2A. In the analysis, scenarios of radionuclide release from the 200 East Area Low-Level waste facility was evaluated. The analysis focused on two primary scenarios leading to exposure. The first was inadvertent intrusion. In this scenario, it was assumed that institutional control of the site and knowledge of the disposal facility has been lost. Waste is subsequently exhumed and dose from exposure is received. The second scenario was groundwater contamination.In this scenario, radionuclides are leached from the waste by infiltrating precipitation and transported through the soil column to the underlying unconfined aquifer. The contaminated water is pumped from a well 100 m downstream and consumed,causing dose. Estimates of potential contamination of the surrounding environment were developed ...
1996-08-15
Energy Technology Data Exchange (ETDEWEB)
In order for fuel cells to be successful, a full-scale hydrogen infastructure is required. The HyTra concept is presented here (HYdrogen TRAnsform, Transfer and TRAnsport) involves combined production, storage and supply of hydrogen in a transportable trailer, i.e. it is both a hydrogen production unit and a mobile filling station. The trailer can be transported to the selected site, where it will produce gaseous hydrogen from electricity and water by electrolysis. A compressor pumps the gas into an internal pressure tank and compresses it to filling pressure. Filling takes place by the overflow principle via a flexible high-pressure line with a standardised H{sub 2} filling unit. (orig.) [German] Um die Marktdurchdringung der Brennstoffzellentechnik gewaehrleisten zu koennen, muss eine flaechendeckende Wasserstoffinfrastruktur aufgebaut werden. Das neue HyTra-Konzept (HYdrogen TRAnsform, TRAnsfer and TRAnsport) beruht auf der Kombination von ...
2006-11-15
Engineering masterpieces : from the Andes to Siberia, Canadian talent is in demand
Energy Technology Data Exchange (ETDEWEB)
Canadian oilfields are a prime breeding ground for talent, technology and industrial management. This paper described how Canadian talent was recognized in 2001 for three major projects which included a cold-ocean production platform in the Sea of Okhotsk in Siberia, a mountain pipeline project in South America, and an in-situ underground extraction technology in the oilsands of Alberta. The cold-ocean production platform project was recruited by Sakhalin Energy Investment Co., an international consortium originally led by Marathon Oil Co which is now led by Royal Dutch Shell. The oil production platform is stationed 16 kilometres offshore of Sakhalin Island in the Sea of Okhotsk. Sakhalin Energy bought and converted the Molikpaq, an innovative platform made in the 1980s for the Beaufort Sea by Gulf Canada Resources Ltd. The second project included Calgary's Hydroconsult EN3 Services Ltd. which was responsible for the construction of the 940-km GasAtacama 24-inch diameter ...
2001-03-05
Data Center Energy Benchmarking: Part 4 - Case Study on aComputer-testing Center (No. 21)
Energy Technology Data Exchange (ETDEWEB)
The data center in this study had a total floor area of 8,580 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 440 racks, and was located in a 208,240 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but served by the main building chiller plant and make-up air system. Additionally, it was served by a single electrical supply with no provision for backup power. The data center operated on a 24 hour per day, year-round cycle, and users had all hour full access to the data center facility. The study found that data center computer load accounted for 23% of the overall building electrical load, while the total power consumption attributable to the data center including allocated cooling load and lighting was 30% of the total facility load. The density of ...
2007-08-01
Criticality calculations of the fixed bed nuclear reactor
Energy Technology Data Exchange (ETDEWEB)
The Fixed Bed Nuclear Reactor (FBNR) is a small 40 MWe reactor based on the Pressurized Water Reactor (PWR) technology. FBNR is an integrated primary circuit and simple in design. It has the characteristics of being small, modular, proliferation resistant, inherently safe and passively cooled reactor with reduced adverse environmental impact. It utilizes the fuel designed for high temperature reactors operating in a relatively low temperature of PWR environment The 15 mm diameter spherical fuel elements are made of TRISO type microspheres embedded in graphite and cladded by SiC. The coolant flow transfers them from the fuel chamber into the core and become fixed forming a suspended core. Any accident signal will cut off the power to the coolant pump causing a stop in the flow. This results in making the fuel elements fall out of the reactor core by the force of gravity and return into the fuel chamber where they are passively cooled under ...
2007-07-01
Energy Technology Data Exchange (ETDEWEB)
Organic Rankine cycles (ORC) have unique properties that are well suited to solar power generation. In this work design and performance calculations are performed using MatLab/SimuLink computational environment. The cycle consists of thermal solar collectors (Flat Plate Solar Collector (FPC), or Parabolic Trough Collector (PTC), or Compound Parabolic Concentrator (CPC)) for heat input, expansion turbine for work output, condenser unit for heat rejection, pump unit, and Reverse Osmosis (RO) unit. Reverse osmosis unit specifications used in this work is based on Sharm El-Shiekh RO desalination plant. Different working fluids such as: butane, isobutane, propane, R134a, R152a, R245ca, and R245fa are examined for FPC. R113, R123, hexane, and pentane are investigated for CPC. Dodecane, nonane, octane, and toluene are allocated for PTC. The proposed process units are modeled and show a good validity with literatures. Exergy and cost analysis are performed for saturation ...
2010-11-15
Energy Technology Data Exchange (ETDEWEB)
A field experiment was held in the northwestern Taiwan as a part of a long-term research program for studying Taiwan`s local circulation. The program has been named as Taiwan Regional-circulation Experiment (TREX). The particular goal of this research is to investigate characteristics of boundary layer and local Circulation and their impact on the distribution and Variation of pollutants in the northwestern Taiwan during Mei-Yu season. It has been known for quite sometime that land-sea breeze is very pronounced under hot and humid conditions. Extensive network includes 11 pilot ballon stations, 3 acoustic sounding sites, and 14 surface stations in about 20 km by 20 km area centered at National Central University, Chung-Li. In addition, there are ground temperature measurements at 3 sites, Integrated Sounding System (ISS) at NCU, air plane observation, tracer experiment with 10 collecting stations, 3 background upper-air ...
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
This article describes acoustic methods used in the in-service inspection of the dams and peripheral concrete structures of the Toktogul, Kurpsai, and Bratsk hydroelectric and pumped storage plants. The tests were conducted to assess the compression strength, elasticity, and tensile strength of the concretes. Comparative evaluations against drill core studies proved the acoustic methods to be sufficiently accurate in predicting aging behavior and loss of mechanical and physical integrity in the concretes.
1987-09-01
The trick with the heat pump; Der Trick mit der Waermepumpe
Energy Technology Data Exchange (ETDEWEB)
The brochure reports on the construction and method of operation of heat pumps: - Efficiency and temperature difference - output figure - circuit processes - saving of primary energy - monovalent and bivalent plants - absorber, earth collectors - heat recovery. (HW) [Deutsch] Die Broschuere berichtet ueber den Aufbau und die Wirkungsweise von Waermepumpen: - Wirkungsgrad und Temperaturdifferenz - Leistungszahl - Kreisprozesse - Einsparung von Primaerenergie - monovalente und bivalente Anlagen - Absorber, Erdkollektoren - Waermerueckgewinnung. (HW)
1997-12-31
THERMALLY CONDUCTIVE CEMENTITIOUS GROUTS FOR GEOTHERMAL HEAT PUMPS. PROGRESS REPORT BY 1998
Energy Technology Data Exchange (ETDEWEB)
Research commenced in FY 97 to determine the suitability of superplasticized cement-sand grouts for backfilling vertical boreholes used with geothermal heat pump (GHP) systems. The overall objectives were to develop, evaluate and demonstrate cementitious grouts that could reduce the required bore length and improve the performance of GHPs. This report summarizes the accomplishments in FY 98.
1998-11-01
Simulation of a geothermal heat pump with non-azeotropic mixture
Energy Technology Data Exchange (ETDEWEB)
The paper sets up a simulation of a geothermal heat pump with a non-azeotropic mixture. The model is modified and verified with experimental data. The results of the simulation show that the systematic model can predict the performance within {+-}12% of the experimental data. As a result, some improvements can be provided on the basis of the simulation platform. (Author)
2003-08-01
...understanding sweden publication publication market publications publications inco publications library public-private partnerships publishing publishing platform pufafeed puglia pulmonary diseases pulp puma pumped hydro storage pumped storage plants purity purpose purpose-grown energy crops purposes pv pv added value pv cells pv crystalline cells pv organic and polymer cells pv research pv ...
Pumped storage in the future power supply system
Energy Technology Data Exchange (ETDEWEB)
Pumped storage plants (PSP) supply up to several GW of power and several ten GWh of capacity. Short start-up times and low start-up costs predestine PSP for the control energy market. Grid charges for PSP endanger the further integration of renewable energy and lead to higher electricity supply costs. Therefore, an amendment of legislation is urgently required. Requirements for building large PSP are met at numerous sites in the low mountain ranges of Germany. (orig.)
2010-07-01
Periodic optimal control with application to pumped storage plants
Energy Technology Data Exchange (ETDEWEB)
This paper suggests how nonlinear periodic optimal control of a pumped storage plant can be realized. The control problem consists in maximization of the plant benefits over an operational period. An optimal control law is proposed, yielding a bang-off-bang mode of operation. An algorithm for numerical solution of the problem was developed, and its effectiveness was demonstrated by simulation experiments.
1987-04-01
Modularity for bio business growth
British Library Electronic Table of Contents (United Kingdom)
Interchangeable technology from Flexicon Liquid Filling, a business division of Watson-Marlow Pumps Group, has helped family-run diagnostic reagent manufacturer, Hart Biologicals Ltd, to accommodate business growth with the recent upgrade to a tabletop bottle filling and capping machine. A peristaltic dispensing pump is crucial for succes
2011-01-01
Main-coolant-pump shaft-seal reliability investigation. Interim report
Energy Technology Data Exchange (ETDEWEB)
This report contains the results of a survey of reactor coolant pump shaft seal reliability. The survey sample is representatively large (approx. = 27% of total US commercial plant population) and includes the three industry seal suppliers (Bingham-Williamette, Byron Jackson, and Westinghouse). Operationally incurred/induced problems and seal redesign parameters are identified. Failure hypotheses in the form of fault trees have been developed to describe the failure mechanisms. Recommendations are made for seal reliability improvement.
1982-09-01
Energy Technology Data Exchange (ETDEWEB)
Heat pumps can be installed indoors or outdoors. H. Klein investigates which site would be preferable for a one-family house. Advantages and disadvantages with regard to necessary space, noise, maintenance and repair are discussed; heat losses in both cases of installations are dealt with. Mathematic calculation shows that indoor installation is safer and more adequate in terms of energy savings.
1982-06-01
Energy Technology Data Exchange (ETDEWEB)
This workshop on heat pipes and two-phase capillary pumping loops was organized by the French society of thermal engineers. The 11 papers presented during this workshop deal with the study of thermal performances of heat pipes and on their applications in power electronics (cooling of components), and their use in satellites, aircrafts and trains. (J.S.)
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
The paper describes a way to control methane that is almost self-sufficient. The Methane Buster extracts methane from longwall mines. The machinery can run virtually unattended and is fuelled by a small proportion of the methane that it extracts. The most popular model is the size of a car and weighs 3000 lbs. With pump inlet sizes varying from 6 to 24 ins. The pumps can handle up to 30,000 CFM. 3 photos.
2005-12-01
Energy Technology Data Exchange (ETDEWEB)
Within the Westeuropean network of the electric current supply a continuing compensation is necessary with respect to the permanent alterations of capacity and frequency. Pumped-storage plants are of considerable significance to meet these requests. The Schluchseewerk AG, Freiburg/Breisgau, has among others five pumped-storage plants in the southern part of the Black Forest. The conception and the operation of them are described. (orig.).
1991-03-01
Developing geothermal heat pump demonstration projects
Energy Technology Data Exchange (ETDEWEB)
The Sacramento Municipal Utility District is developing a number of demonstration projects using geothermal heat pumps. This paper discusses some of the barriers and issues that have emerged over the past two years. The most important barriers are: regulatory impediments; high first cost; and a lack of local design and installation infrastructure.
1995-12-31
Coumarin-4 laser efficiency up to 0. 14% under coaxial flash-lamp pumping
Energy Technology Data Exchange (ETDEWEB)
Under coaxial flash lamp pumping the laser efficiency of coumarin-4 in slightly basic ethyl alcohol solution as an active medium has reached a value of 0.14%. That is three times higher than that in the basic aqueous solution. Its tunable wavelength range of laser output has extended from 440 to 510 nm with the maximum at 460 nm.
1987-02-01
AUTOMATIC LIQUID NITROGEN PUMPING SYSTEM FOR PARTICLE ACCELERATORS
A description is given of an automatic liquid nitrogen pumping system. Pamping of liquid nitrogen iato cooling traps up to a predetermined level is achieved by an automatically controlled compressed air system. An impontant feature of the equipment is the ability to switch automatically from an empty liquid nitrogen reservoir to a full one. This allows for a much more flexible operation than in conventional systems where the reservoir has to be replaced manually when empty. (auth)
1963-04-16
API Report/LOOP (Louisiana Offshore Oil Port) startup will ease crude import handling problems
A description of LOOP covers the single point mooring (SPM) system; the offshore pipelines connecting each SPM to the pumping platform; the offshore platform complex, a pumping platform and a control platform; the onshore pipelines; and the Clovelly Dome storage terminal.
1979-01-01
Pumped-storage: peak generation or operating reserve
Energy Technology Data Exchange (ETDEWEB)
The trade-off which must be established between the various functions of pumped-storage plants is examined. A compromise between supply security and economic planning can be found only by coordinated planning of pumped-storage units and thermal generation plants. A model used by Electricite de France (EDF) to ensure optimized daily planning of thermal and pumped-storage units is described. The model, called the DEMETER model, ensures the optimization of the daily planning of thermal and pumped-storage plants. The model iterates between two levels: coordination where the prices of the generated energy and the operating reserve are determined to adjust generation to load and keep a sufficient reserve; and decomposition where the schedule of each unit is optimized on the basis of the above prices and taking into account local constraints such as unavailability, and minimum shut down time. The role of EDF ...
1984-08-01
Energy Technology Data Exchange (ETDEWEB)
The large number of forms and types of pump equipment in common use have different purposes and varying application requirements. This text has been prepared to bring together necessary information for those who are required to select and apply pumps in systems for all kinds of fluids and purposes. It is not a design manual. It limits the discussion of design to those factors which are necessary for an understanding of pump operation. The book contains not only descriptive information of many types of designs, but also the effect of design variation on use, economy, and reliability. Systems, an integral part of application, are discussed, so that the user of such equipment may properly select and install machines to reliably and economically satisfy his requirements. Reading of appropriate sections of the text will indicate possible problems to be avoided, and economics to be gained. The engineering design of ...
1990-01-01
Lasing efficiency and tuning range of a dynamic distributed-feedback laser
Energy Technology Data Exchange (ETDEWEB)
The effects of the contrast of the pump field interference pattern, that is, the effectiveness of the dynamic amplitude-phase grid, and various optical arrangements on the lasing efficiency and tuning range of a dynamic distributed-feedback dye laser are investigated. It is shown that the proper choice of prism apex angle, prism material and dye solvent in a laser in the range 400-1000 microns pumped by two beams of different intensity directed through the congruent sides of an isosceles prism in contact with the active medium solution on its third side can lead to optical losses of less than 2% from the boundaries of the prism. Measurements of polymethine dye laser efficiency and tuning range as a function of the relative intensity of the two ruby-laser pump beams reveals that as the contrast of the pump beam interference pattern decreases, the tuning range remains practically constant and the ...
1980-08-01
Water Quality Criteria | Water Quality Criteria | US EPA
for? Learn the Issues Science & Technology Laws & Regulations About EPA Contact Us Water: Water Quality Criteria You are here: Water Science & Technology Surface Water Standards &...
2011-08-28
International Nuclear Information System (INIS)
... thermal power plants thermal reactors water cooled reactors WATER
Some applications of nuclear techniques in hydrology and water pollution studies in Norway
International Nuclear Information System (INIS)
... hydrology norway water pollution pollution scandinavia surface waters
Energy Technology Data Exchange (ETDEWEB)
In this article the methodology followed to diagnose the performance of the equipment where heat is transferred from the feed water, condensate and circulation water systems in fossil power plants (FPP). The data collection is made with the unit in normal operation, using local instrumentation without taking the equipment out of service for its installation. The equipment diagnosis is made through the analysis of the collected data in actual operation and the design data; for this purpose a thermal balance of the interested systems is performed to obtain all the conditions an operation data. Later on the performance indicative parameters (PIP) of actual operation and design are calculated and compared one against the other. Such a comparison reveals the performance deterioration and the possible equipment faults. The data obtained and the supplementary information are stored in a data base whose objective is that Comision ...
1990-12-31
International Nuclear Information System (INIS)
Alloy 800 and Alloy 600 are well known for their resistance to corrosion in an aqueous medium at high pressure and temperature, for which they have been widely used for more than 3 decades in different structural components of water refrigerated nuclear reactors, especially as material for the steam generator tubes (SG) in these nuclear plants. The SG tubes in the Atucha I and Embalse Nuclear Plants are made with Alloy 800. The speed of corrosion of these materials in a reactor's refrigerant medium, while very small is perfectly measurable and can be described by parabolic or logarithmic type kinetics. In other words this speed is high in the first states of growth during the formation of a protective oxide film but then drops to almost stationary values. One characteristic of these films is the formation of a double layer (or duplex): i) an internal adhering layer, of approximately constant thickness, formed by small microcrystals (#<=#0.05 mm), ii) a less ...
2006-12-01
Energy Technology Data Exchange (ETDEWEB)
The objective of this project was to develop new photocatalytic or other innovative process chemistry for the treatment of pink water and related contaminated water.
1996-10-01
Energy Technology Data Exchange (ETDEWEB)
Volume 2 of the water resources data for the 1992 water year for Oklahoma consists of record of stage, discharge, and water quality of streams; stage, contents, and water quality of lakes or reservoirs; and water levels of ground-water well. The report contains discharge records for 136 gaging stations; stage and contents for 31 lakes or reservoirs; water quality for 50 gaging stations. Also included are 61 partial-record or miscellaneous streamflow stations and 28 ground-water sites.
1993-04-01
International Nuclear Information System (INIS)
The intensity of erbium up-conversion luminescence could be limited by a saturation effect due to increased pump power. We studied the luminescence saturation of the 550 nm emission on erbium-doped, SiO_2-TiO_2 sol-gel powders under pulsed excitation at 979 and 1532 nm. From the latter, the up-converted luminescence intensity decreased with increasing excitation power, whereas no saturation was observed at 979 nm excitation. We proposed that the saturation effect is determined by the pump power, the erbium content and the lifetime of the corresponding first excited states at different pumping schemes.
2010-12-01
Spontaneously generated atomic entanglement in free space: reinforced by incoherent pumping
We study spontaneously generated entanglement (SGE) between two identical multilevel atoms in free space via vacuum-induced radiative coupling. We show that the SGE in two-atom systems may initially increase with time but eventually vanishes in the time scale determined by the excited state lifetime and radiative coupling strength between the two atoms. We demonstrate that a steady-state SGE can be established by incoherently pumping the excited states of the two-atom system. We have shown that an appropriate rate of incoherent pump can help producing optimal SGE. The multilevel systems offer us more chanel to establish entanglement. The system under consideration could be realized in a tight trap or atoms/ions doped in a solid substrate.
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
Currently the construction of small-scale hydroelectric and pumped storage plants is booming in the USA. The technology is attractive because of its relatively cheap construction methods and operation. Electric utilities are seeing it as a viable source of peaking power and a means of system regulation. Two schemes are described. One is a high-head/small flow river project designed to generate 3.5 MW and is about to come on line having overcome tight environmental and commercial constraints. The second is a pumped-storage project using two man-made reservoirs with an average elevation difference of 1280 ft. It is deemed to be of minimum environmental impact construction and good physical characteristics. Completion is hoped for by 1995 and the plant will deliver 1000 MW. (UK)
1994-04-01
Performance of a diode-pumped laser repetitively Q-switched with a mechanical shutter.
Repetitively Q-switched operation of an end-pumped Nd:YAG laser over the range of 200 Hz to 3 kHz using an intracavity chopper is demonstrated. Performance is shown to be comparable to that achieved with an acousto-optic Q switch under similar conditions. The advantages and limitations of the mechanical Q switch are described. Parametric variations of output coupling and pump power lead to an extended empirical description of repetitively Q-switched laser operation. The insertion loss as a function of aperture-edge penetration into the resonator is reported, and a definition of the mechanical Q-switch opening time is provided. Q-switched pulsewidths as short as 35 ns were obtained for the Nd:YAG laser, with a peak power-enhancement factor in excess of 300. PMID:20862099
1994-02-20
Buried-heterostructure semiconductor Raman laser with threshold pump power less than 1 W
Energy Technology Data Exchange (ETDEWEB)
The low-power operation of a semiconductor buried-heterostructure Raman laser is reported. We are developing these devices for very wide-band optical communication in the terahertz frequency region. It has a structure with a GaP active layer and Al{sub {ital x}}Ga{sub 1{minus}{ital x}}P cladding layers, which are grown by the temperature-difference method under controlled vapor pressure. By making the stripe width 30--40 {mu}m, we have obtained a threshold pump power of 500 mW. A low-threshold semiconductor Raman laser can be pumped by semiconductor injection lasers. We have measured the optical loss of the waveguide and detected the contribution from scattering and leakage at heterointerfaces.
1989-12-01
A Study on the Construction Plan for Vibration Analysis System of HANARO Rotating Machinery
Energy Technology Data Exchange (ETDEWEB)
The objective of this study is to establish a construction plan for vibration analysis system of HANARO's rotating machinery. To achieve this purpose, as a first step, the references related to the vibration analysis system for the rotating machinery were investigated. In addition, to verify the possibility of condition monitoring of the pumps, vibration signals obtained from the vibration monitoring system were analyzed. The results show that using the accelerometers mounted on the bearing locations of the pumps can monitor the current status of the pump such as unbalance, misalignment, and bearing condition. Based on the results of this study, the construction plans for the vibration analysis system of HANARO have been established. The hardware of the vibration analysis system will be installed by the end of this year. It is expected that the developed vibration analysis system can be utilized for the realization ...
2005-10-15
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent