WorldWideScience
1

Unusual Recharge Processes near Arroyos of the Rio Grande Aquifer, El Paso/Juarez Area  

Science.gov (United States)

The twin-cities of El Paso and Juarez share the water resources of the Hueco Bolson aquifer and overlying Rio Grande aquifer. Both aquifers span the international border between Mexico and the United States. Salinity in the Rio Grande aquifer varies widely, some parts of the shallow aquifer containing less than 1,000 mg/L total dissolved solids (TDS), other parts of the aquifer exceeding 5,000 mg/L TDS. One sizable part of the "Lower Valley" area, approximately 45 km below El Paso contains very dilute water near the outer edge of the floodplain. Historically it had been thought that the dilute waters in this location were derived from recharge from arroyos that drained proximal parts of the Hueco Bolson. Instead, our hydrogen and oxygen isotope data and carbon-14 data indicate ...

2005-12-01

2

Occurrence of fecal indicator bacteria in surface waters and the subsurface aquifer in Key Largo, Florida.  

UK PubMed Central (United Kingdom)

Sewage waste disposal facilities in the Florida Keys include septic tanks and individual package plants in place of municipal collection facilities in most locations. In Key Largo, both facilities discharge...Full Text Available

1995-06-01

3

Monitoring of the Water Levels in the Wetlands of Fourmile Branch near the F and H Areas of SRS: January - December 2000  

Energy Technology Data Exchange (ETDEWEB)

In 2000, a network of twenty-three piezometers was used to measure hydraulic head in the water-table aquifer (Upper Aquifer Zone of the Upper Three Runs Aquifer, or UAZ of the UTRA) along the ground water outcrops (i.e. seeplines) near the F- and H-Areas.

2001-07-10

4

Raft River monitor well potentiometric head responses and water quality as related to the conceptual ground-water flow system  

Energy Technology Data Exchange (ETDEWEB)

Ground-water monitoring near the Raft River site was initiated in 1974 by the IDWR. This effort consisted of semiannual chemical sampling of 22 irrigation wells near the Raft River geothermal development area. This program yielded useful baseline chemical data; however, several problems were inherent. For example, access to water pumped from the wells is limited to the irrigation season (April through September). All the wells are not continuously pumped; thus, some wells that are sampled one season cannot be sampled the next. In addition, information on well construction, completion, and production is often unreliable or not available. These data are to be supplemented by establishing a series of monitor wells in the proposed geothermal withdrawal and injection area. These wells were to be located and designed to provide data necessary for evaluating and predicting the impact of geothermal development on the Shallow ...

1982-09-01

5

Simulation of ground-water flow in the basin-fill aquifer of the Tularosa Basin, south-central New Mexico, ...  

Science.gov (United States)

... percent by interbasin ground-water flow into the Hueco Bolson, and 2 percent by flow into creeks and ... ...

6

Origin of water salinity in the coastal Sarafand aquifer (South-Lebanon)  

International Nuclear Information System (INIS)

Author.The geochemical and isotopic study, based on the analysis of twenty water samples from well in the coastal plain of Sarafand (South-Lebanon), permit to eliminate the hypothesis of marine intrusion in this aquifer. The increase of salinity observed in certain wells is due to the contamination of cretaceous aquifer water by the quaternary formations. The two poles of mixing are respectively characterized: by weak tritium contents (between 2 and 3 UT) and a value of stable isotopes (-5,9<0,18<-5,5) corresponding to the appearance of cretaceous formation area; by the high tritium contents and enrichment relative to heavy isotope in the mineralized water of superficial formations. On the other hand, the isotope contents permit the set a rapid renewal of the cretaceous aquifer water due to quick circulation in the Karstic system

7

Assessment of groundwater quality in crystalline fractured aquifers in rural agricultural area of the mid-western coastal parts of South Korea  

International Nuclear Information System (INIS)

Full text: Groundwater in rural agricultural area of South Korea is an important source of drinking and agricultural water. The study area is located in mid-western coastal parts and has fractured bedrock aquifers whose lithologies are composed of Jurassic granites, Paleozoic sedimentary rocks, Precambrian schists and gneiss. Bedrock groundwater was slightly alkaline and had electrical conductivity of 40 to 1570 #mu#S/cm with median values of 322 #mu#S/cm. Water types based on major ions showed that Ca-HCO_3 and Ca-CI types are dominant and Na-HCO_3 and Na-CI types are minor. Intense agricultural activities resulted in significant nitrate contamination of groundwater. 22% and 40% of wells have exceeded drinking water standards (DWS) for bedrock and shallow wells, respectively. In coastal areas, slightly saline groundwater is observed for both bedrock and shallow wells. Groundwater ...

2010-11-15

8

Identification of source and recharge zones in an aquifer system from water stable isotope. Case Study Bajo Cauca Antioqueno  

International Nuclear Information System (INIS)

Hydrology and hydrogeochemical are auxiliary techniques to valid conceptual hydrogeology an recharge models. Stable isotopes from water trace sources and path flow and Tritium indicates age. This paper is about the use of D 18, D2H y 3H to study the aquifer system on Bajo Cauca antioqueno.

9

Monitoring of the Water Levels in the Wetlands of Fourmile Branch Near the F- and H-Areas of SRS: FY97  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the piezometer network is to establish baseline hydraulic head data for the water table aquifer at the F- and H-Area seeplines prior to startup of the groundwater extraction/injection remediation system.

1999-06-02

10

The mobility of anthropogenic {sup 129}I in a shallow sand aquifer at Sturgeon Falls, Ontario, Canada  

Energy Technology Data Exchange (ETDEWEB)

The transport and partitioning of {sup 129}I has been examined for a shallow groundwater flow system at Sturgeon Falls in northeastern Ontario. Recharge into a sandy surficial postglacial deltaic aquifer occurs in the vicinity of a seasonally-wet boreal forest. Concentrations of stable iodine, {sup 129}I, tritium, radiocarbon, stable isotopes and major ions were measured on samples of groundwater and precipitation. The present-day tritium profile delineates the position of the early 1960's above-ground nuclear weapons pulse at a depth of approximately 12 m. The concentrations of stable iodine for groundwaters above, near and below the above-ground nuclear weapons pulse range from 0.07 to 1.7 ppb. Over that same interval {sup 129}I concentrations decreased from 1.9 x 10{sup 6} atoms/L at 9 m, to approximately 1.9 x 10{sup 5} atoms/L in tritium-depleted waters at 35 m, below the present-day depth of the recharging above-ground nuclear ...

2005-07-01

11

Contingency interim measure for the public water supply at Barnes, Kansas.  

Energy Technology Data Exchange (ETDEWEB)

This document presents a conceptual design for a contingency interim measure (IM) for treatment of the public water supply system at Barnes, Kansas, should this become necessary. The aquifer that serves the public water supply system at Barnes has been affected by trace to low concentrations of carbon tetrachloride and its degradation product, chloroform. Investigations conducted on behalf of the CCC/USDA by Argonne National Laboratory (Argonne 2008a) have demonstrated that groundwater at the Barnes site is contaminated with carbon tetrachloride at concentrations exceeding the Kansas Tier 2 risk-based screening level (RBSL) and the EPA maximum contaminant level (MCL) of 5.0 {micro}g/L for this compound. The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) formerly operated a grain storage facility in Barnes, approximately 800 ft east-southeast of the public water supply ...

2009-07-09

12

Source and mobility of minor and trace elements in a volcanic aquifer system: Mt. Vulture (southern Italy)  

British Library Electronic Table of Contents (United Kingdom)

In this paper we provide a geochemical investigation on 34 groundwater samples in the Mt. Vulture volcanic aquifer representing one of the most important groundwater resources of the southern Italy pumped for drinking and irrigation supply. The present study includes the first data on the abundance and mobility of minor and trace elements and the thermodynamic considerations on water-rock interaction processes in order to evaluate the conditions of alkali basalt weathering by waters enriched in magma-derived CO2. The results highlight the occurrence of two hydrofacies: bicarbonate alkaline-earth and alkaline waters deriving from low-temperature leaching of volcanic rocks of Mt. Vulture, and bicarbonate-sulfate-alkaline waters (high-salinity waters) related to prolonged water circulation in...

2011-01-01

13

Simulations of Groundwater Flow and Radionuclide Transport in the Vadose and Saturated Zones beneath Area G, Los Alamos National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

Numerical simulations are used to predict the migration of radionuclides from the disposal units at Material Disposal Area G through the vadose zone and into the main aquifer in support of a radiological performance assessment and composite analysis for the site. The calculations are performed with the finite element code, FEHM. The transport of nuclides through the vadose zone is computed using a three-dimensional model that describes the complex mesa top geology of the site. The model incorporates the positions and inventories of thirty-four disposal pits and four shaft fields located at Area G as well as those of proposed future pits and shafts. Only three nuclides, C-14, Tc-99, and I-129, proved to be of concern for the groundwater pathway over a 10,000-year period. The spatial and temporal flux of these three nuclides from the vadose zone is applied as a source term for the three-dimensional saturated zone model of the main ...

1999-07-01

14

Implementation of the national desalination and water purification technology roadmap : structuring and directing the development of water supply solutions.  

Energy Technology Data Exchange (ETDEWEB)

In the United States, economic growth increasingly requires that greater volumes of freshwater be made available for new users, yet supplies of freshwater are already allocated to existing users. Currently, water for new users is made available through re-allocation of xisting water supplies-for example, by cities purchasing agricultural water rights. Water may also be made available through conservation efforts and, in some locales, through the development of ''new'' water from non-traditional sources such as the oceans, deep aquifer rackish groundwater, and water reuse.

2006-06-01

15

Contamination and restoration of groundwater aquifers  

Energy Technology Data Exchange (ETDEWEB)

Humans are exposed to chemicals in contaminated groundwaters that are used as sources of drinking water. Chemicals contaminate groundwater resources as a result of waste disposal methods for toxic chemicals, overuse of agricultural chemicals, and leakage of chemicals into the subsurface from buried tanks used to hold fluid chemicals and fuels. In the process, both the solid portions of the subsurface and the groundwaters that flow through these porous structures have become contaminated. Restoring these aquifers and minimizing human exposure to the parent chemicals and their degradation products will require the identification of suitable biomarkers of human exposure; better understandings of how exposure can be related to disease outcome; better understandings of mechanisms of transport of pollutants in the heterogeneous structures of the subsurface; and field testing and evaluation of methods proposed to restore and cleanup contaminated ...

1993-04-01

16

Cape Cod Aquifer Management Project (CCAMP): hydrogeologic papers. Report for August 1985-December 1987  

Energy Technology Data Exchange (ETDEWEB)

The project was initiated in 1985 with the goal of studying existing federal, state, and local programs for protecting and preserving Cape Cod's sole-source aquifer. To meet this need, the Massachusetts Department of Environmental Quality Engineering and the U.S. Environmental Protection Agency's Region 1 in cooperation with the Cape Cod Planning and Economic and Development Commission and the U.S. Geological Survey initiated a two-year study to determine the adequacy of current ground-water protection programs and to recommend improvements. In the process of gathering and evaluating hydrogeological data from the Towns of Barnstable and Eastham, the CCAMP Aquifer Assessment Committee developed the papers which are the subject of this publication. These studies formed the technical basis for groundwater resource management decision making.

1988-09-01

17

Evaluation of the Validity of Groundwater Samples Obtained Using the Purge Water Management System at SRS  

Energy Technology Data Exchange (ETDEWEB)

As part of the demonstration testing of the Purge Water Management System (PWMS) technology at the Savannah River Site (SRS), four wells were equipped with PWMS units in 1997 and a series of sampling events were conducted at each during 1997-1998. Three of the wells were located in A/M Area while the fourth was located at the Old Radioactive Waste Burial Ground in the General Separations Area.The PWMS is a ''closed-loop'', non-contact, system used to collect and return purge water to the originating aquifer after a sampling event without having significantly altered the water quality. One of the primary concerns as to its applicability at SRS, and elsewhere, is whether the PWMS might resample groundwater that is returned to the aquifer during the previous sampling event. The purpose of the present ...

1999-04-27

18

Improved disposal-water treatment at Bahrain oil fields  

Science.gov (United States)

Bahrain's Awali oil field is one of the oldest in the Arabian Gulf region. The recent sharp increase in produced water cut at Awali has resulted in higher oil carry-over in the produced water, which is currently disposed of in an aquifer about 700 ft (210 m) deep. The steps taken by Bahrain Natl. Oil Co. (Banoco) and the problems encountered in improving the quality of effluent are described in this paper.

1988-11-01

19

Studies of the behaviour of technical chemicals introduced into the subsoil under modelled conditions  

International Nuclear Information System (INIS)

Because of the environmental hazard of organic solvents such as chlorinated or aromatic hydrocarbons, water soluble and biodegradable substitutes have come into use. It should be assessed how they affect soil and aquifer when spilled in leaks or accidents. This was simulated in a model system using methanol and percolation columns, one filled with material from the unsaturated subsurface and two with different materials from aquifers. The results reveal that a spill of the substitutes can also cause problems. In homogeneous soils and at long retention times until the substance reaches the aquifer, sorption and biological degradation are most likely to prevent contamination of the groundwater. When oxygen supply in the subsurface is insufficient, reducing conditions occur and sulphide is formed. The data show that much more methanol was eliminated than reflected by the consumption of electron acceptors. ...

1993-04-01

20

Preliminary delineation of natural geochemical reactions, Snake River Plain aquifer system, Idaho National Engineering Laboratory and vicinity, Idaho  

Energy Technology Data Exchange (ETDEWEB)

The U.S. Geological Survey, in cooperation with the U.S. Department of Energy, is conducting a study to determine the natural geochemistry of the Snake River Plain aquifer system at the Idaho National Engineering Laboratory (INEL), Idaho. As part of this study, a group of geochemical reactions that partially control the natural chemistry of ground water at the INEL were identified. Mineralogy of the aquifer matrix was determined using X-ray diffraction and thin-section analysis and theoretical stabilities of the minerals were used to identify potential solid-phase reactants and products of the reactions. The reactants and products that have an important contribution to the natural geochemistry include labradorite, olivine, pyroxene, smectite, calcite, ferric oxyhydroxide, and several silica phases. To further identify the reactions, analyses of 22 representative water samples from sites tapping the ...

1997-05-01

21

Potential for geothermal development in Southern Poland  

Energy Technology Data Exchange (ETDEWEB)

This paper discusses the potential for geothermal energy use in the central part of Southern Poland, such as the availability of thermal aquifers and the techniques for putting the latter to practical use. The geological and geothermal features of the region are presented within the context of the existence of aquifers containing geothermal resources that could be used in space heating. Also discussed are the three main geological units where thermal waters are known to exist: the Carpathians, the Miechow Trough, and the Silesian-Cracow Monocline. Particularly favourable hydrogeological conditions exist in the Inner Carpathians, in the Podhale Trough, where there is already one geothermal company using geothermal energy, Geotermia Podhalanska S.A. Equally interesting from the geothermal point of view are the areas north of the Cracow-Tarnow line, where, in Mesozoic aquifers, water ...

2004-06-01

22

Mixed Waste Management Facility (MWMF) groundwater monitoring report, second quarter 1992  

Energy Technology Data Exchange (ETDEWEB)

During second quarter 1992, tritium, trichloroethylene, tetrachloroethylene, chloroethene, antimony, 1,1-dichloroethylene, lead, nonvolatile beta, radium-228, thorium-228, or total alpha-emitting radium (radium-226 and radium-228) exceeded the US Environmental Protection Agency Primary Drinking Water Standards (PDWS) in groundwater samples from monitoring wells at the Mixed Waste Management Facility (MWMF) and adjacent facilities. Tritium and trichloroethylene were the most widespread constituents; 55 (48%) of the 115 monitored wells contained elevated tritium activities, and 23 (20%) wells exhibited elevated trichloroethylene concentrations. Sixty-three downgradient wells screened in Aquifer Zone IIB2 (Water Table), Aquifer Zone IIB[sub 2] (Barnwell/McBean), and Aquifer Unit IIA (Congaree) contained concentrations of tritium, trichloroethylene, tetrachloroethylene, chloroethene, ...

1992-09-01

23

Comparison of potential radiological consequences from a spent-fuel repository and natural uranium deposits  

Energy Technology Data Exchange (ETDEWEB)

A general criterion has been suggested for deep geological repositories containing spent fuel - the repositories should impose no greater radiological risk than due to naturally occurring uranium deposits. The following analysis investigates the rationale of that suggestion and determines whether current expectations of spent-fuel repository performance are consistent with such a criterion. In this study, reference spent-fuel repositories were compared to natural uranium-ore deposits. Comparisons were based on intrinsic characteristics, such as radionuclide inventory, depth, proximity to aquifers, and regional distribution, and actual and potential radiological consequences that are now occurring from some ore deposits and that may eventually occur from repositories and other ore deposits. The comparison results show that the repositories are quite comparable to the natural ore deposits and, in some cases, present less radiological hazard than their natural ...

1980-09-01

24

Construction, Geology, and Aquifer Testing of the Maalo Road ...  

Science.gov (United States)

... Construction, Geology, and Aquifer Testing of the Maalo ... 8-98) Prescribed by ANSI Std Z39-18 Page 3. Construction, Geology, and Aquifer Testing ...

2011-05-13

25

Deforestation and leaching of nitrogen as nitrates into underground water in intertropical zones: The example of Cote d'Ivoire (the Ivory Coast)  

Science.gov (United States)

High nitrate contents (up to 200 mgl) has been observed in wells drilled into fractured aquifers lying beneath layers of weathered and decayed rock in the humid tropics where annual rainfall is over 1,000 mm and where there is no notable pollution. The source of the nitrates is linked mainly with localized deforestation by man.

26

Chapter 11 Aqueous Solutions  

Wastenet

...Chapter 11 Aqueous Solutions Chapter 11 Aqueous Solutions Download the entire chapter (PDF-136k) Drilling to China More water than rivers Saving the aquifer Drying with Xeriscapes Everywhere in the house Rainwater and graywater Creating urban watersheds Wastewater equals ...3851 Powered by Intrcomm Technology's SMC ...

27

Buried Paleo-Phreatic Playa is the Primary Source of Salinity in the Rio Grande and Rio Grande Aquifer, El Paso-Juarez Valley  

Science.gov (United States)

The Rio Grande alluvial floodplain aquifer between El Paso/Juarez and Fort Quitman, Texas has been intensively tilled and irrigated since 1910. Almost since that time, the Rio Grande and its interconnected alluvial aquifer in this stream reach have been affected by excessive salinity problems. Presently, salinity of surface water and groundwater increases from 800 to 2000 mg/L total dissolved solids (TDS) near El Paso, Texas to 2500 to 5500 mg/L TDS near Fort Quitman, Texas, approximately 115 km downstream. Chloride (Cl) and Chloride/Bromide (Cl/Br) ratios increase downstream, with a marked increase in salinity beginning about 45 km below El Paso. Groundwater sampling in an intensively investigated reach of the floodplain aquifer, extending from 35 to 60 km below El Paso identified two distinct water types. The first water type (17 samples) is a relatively ...

2005-12-01

28

F-Area Seepage Basins groundwater monitoring report -- third and fourth quarters 1993. Volume 1  

Energy Technology Data Exchange (ETDEWEB)

During the second half of 1993, the groundwater at the F-Area Seepage Basins (FASB) was monitored in compliance with Module 3, Section C, of South Carolina Hazardous Waste Permit SC1-890-008-989, effective November 2, 1992. The monitoring well network is composed of 87 FSB wells screened in the three hydrostratigraphic units that make up the uppermost aquifer beneath the FASB. A detailed description of the uppermost aquifer is included in the Resource Conservation and Recovery Act Part B post-closure care permit application for the F-Area Hazardous Waste Management Facility submitted to the South Carolina Department of Health and Environmental Control (SCDHEC) in December 1990. Beginning in the first quarter of 1993, the standard for comparison became the SCDHEC Groundwater Protection Standard (GWPS) specified in the approved F-Area Seepage Basins Part B permit. Currently and historically, gross alpha, nitrate, nonvolatile beta, and tritium are ...

1994-03-01

29

Geophysical remote sensing of water reservoirs suitable for desalinization.  

Energy Technology Data Exchange (ETDEWEB)

In many parts of the United States, as well as other regions of the world, competing demands for fresh water or water suitable for desalination are outstripping sustainable supplies. In these areas, new water supplies are necessary to sustain economic development and agricultural uses, as well as support expanding populations, particularly in the Southwestern United States. Increasing the supply of water will more than likely come through desalinization of water reservoirs that are not suitable for present use. Surface-deployed seismic and electromagnetic (EM) methods have the potential for addressing these critical issues within large volumes of an aquifer at a lower cost than drilling and sampling. However, for detailed analysis of the water quality, some sampling utilizing boreholes would be required with geophysical methods being ...

2009-12-01

30

Upward migration of underground injected wastes through hydrologic conduits around the wellbore  

Energy Technology Data Exchange (ETDEWEB)

Underground injection, compared to other waste disposal methods, is considered to have the advantages of isolating wastes in a confined brine aquifer well below the horizon of human activity and underground sources of drinking water (USDWs). While most of injected wastes move laterally in the injection zone, posing a long-term concern to the human health and environment, a small amount can migrate upward to the upper aquifers, causing a greater threat to the quality of USDWs. Both the dual porosity and the single porosity models were used to investigate the migration of injected wastes through these hydrologic conduits. The results indicate that regional upward migration through an extensive confining formation is a slow process. Nevertheless, injected wastes can move upward rapidly through microannuli and channels in the cement sheath and spread over a distance in the upper aquifer. The wastes can also ...

1988-01-01

31

Remotely sensing of excavation cavity during mining  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a method of hydraulically mining a surface of a mining location comprising: a. determining the dimensions of the surface of the mining location from a fixed point at the location; b. constructing at a second location remote from the mining location a visual representation of the surface form the determined dimensions of the mining location with respect to the fixed point; c. jetting water under high pressure against a selected area on the surface of the mining location; d. determining changes in the dimensions of the selected area of the surface of the mining location; e. reconstructing at the second location a new visual representation of the surface from the determined changes of the location during the jetting of the ...

1987-11-24

32

Contribution of climatic and anthropogenic effects to the hydric deficit of peatlands  

British Library Electronic Table of Contents (United Kingdom)

Abstract The present study makes use of a detailed water balance to investigate the hydrological status of a peatland with a basal clay-rich layer overlying an aquifer exploited for drinking water. The aim is to determine the influence of climate and groundwater extraction on the water balance and water levels in the peatland. During the two-year period of monitoring, the hydrological functioning of the wetland showed a hydric deficit, associated with a permanent unsaturated layer and a deep water table. At the same time, a stream was observed serving as a recharge inflow instead of draining the peatland, as usually described in natural systems. Such conditions are not favourable for peat accumulation. Field investigations show that the clay layer has a high hydraulic conductivity (from 11...

2011-01-01

33

Metallurgical Laboratory Hazardous Waste Management Facility groundwater monitoring report. Third quarter, 1994  

Energy Technology Data Exchange (ETDEWEB)

During third quarter 1994, samples from AMB groundwater monitoring wells at the Metallurgical Laboratory Hazardous Waste Management Facility (Met Lab HWMF) were analyzed for selected heavy metals, indicator parameters, radionuclides, volatile organic compounds, and other constituents. Eight parameters exceeded standards during the quarter. As in previous quarters, tetrachloroethylene and trichloroethylene exceeded final Primary Drinking Water Standards (PDWS). Bis(2-ethylhexyl) phthalate exceeded final PDWS in one well. Aluminum, iron, manganese, tin, and total organic halogens exceeded the Savannah River Site (SRS) Flag 2 criteria. Groundwater flow direction and rate in the M-Area Aquifer Zone were similar to previous quarters. Conditions affecting determination of groundwater flow directions and rates in the Upper Lost Lake Aquifer Zone, Lower Lost Lake Aquifer Zone, and the Middle Sand ...

1994-12-01

34

Chemical evolution of formation waters in the Palm Valley gas field, Northern Territory  

International Nuclear Information System (INIS)

The chemical composition and evolution of formation waters associated with gas production in the Palm Valley field, Northern Territory, has important implications for reservoir management, saline water disposal, and gas reserve calculations. Historically, the occurrence of saline formation water in gas fields has been the subject of considerable debate. A better understanding of the origin, chemical evolution and movement of the formation water at Palm Valley has important implications for future reservoir management, disposal of highly saline water and accurate gas reserves estimation. Major and trace element abundance data suggest that a significant component of the highly saline water from Palm Valley has characteristics that may have been derived from a modified evaporated seawater source such as an evaporite horizon. The most dilute ...

35

The use of isotopes in hydrology: Proceedings of a symposium, held in Beirut -Lebanon, December 1970  

International Nuclear Information System (INIS)

The papers presented at the symposium had covered three general areas in which isotopes could have been beneficially used. these areas are: -Water use and water use efficiency studies. -Ground water investigations -Water problems in the arab countries. The individual papers had dealt with these subjects: -Hydrological research in the arab countries by use of radioisotopes. -The perspectives of use of radioisotopes in hydrological studies in Syria. -Water use efficiency and sub-soil water studies. -Sea water inclusion in a coast el aquifers in Lebanon. -Irrigation requirements of crops in Lebanon as determined by a Neutron probe with reference to other methods. -The use of the neutron moisture meter and other methods of the determination of the evapotranspiration of maize. -Ground water ...

1970-12-01

36

Water demand management in areas of ground water over-exploitation  

Environmental Research Database

SummaryIntended Outputs: Identification and evaluation, using participatory approaches, of demand management options:*Technical*Allocative and market based*Impact on target beneficiariesSupporting measures required when introducing water demand management options above:*Extension services & training*Water licences/rights*Institutional changes*Legal measures and regulation*Education*Support in diversifying to less water demanding activities*S [continued...]ObjectivesIdentification of the most appropriate demand management strategies for ground water abstraction, where aquifiers are being over-exploited, ensuring sustainable livelihoods of the vulnerable and poor are safeguarded. Poverty reduction strategies for areas where groundwater is being over-exploited.DescriptionProject Background: Groundwater is the principal source of both irrigation and domestic water supplies in many ...

2006-01-15

37

Microbiological Comparison of Core and Groundwater Samples Collected from a Fractured Basalt Aquifier with that of Dialysis Chamber Incubated in Situ  

Energy Technology Data Exchange (ETDEWEB)

Microorganisms associated with fractured basalt core were compared to those suspended in groundwater pumped from the same well in the eastern Snake River Plain Aquifer (Idaho, USA). Two wells influenced to different degrees by a mixed-waste plume in the fractured basalt aquifer were examined. In one well, an array of dialysis cells filled with either deionized water or crushed basalt was equilibrated to compare the microorganisms collected in this fashion with those from core and groundwater samples collected in a traditional manner from the same well. Analyses were performed to characterize these samples and to provide a basis for comparison. These included total cell counts by microscopy; total biomass by phospholipid fatty acid analysis; enumerations of viable aerobic heterotrophs, groups of putative aerobic co-metabolic TCE-degraders and aerobic H2-oxidizing bacteria; mineralization of 14C- labeled acetate; and ...

2004-04-01

38

ICPP water inventory study project summary report  

Energy Technology Data Exchange (ETDEWEB)

The Idaho Chemical Processing Plant (ICPP) Water inventory Study was initiated in September 1993 with the formation of a joint working group consisting of representatives from DOE-ID, State of Idaho INEL Oversight Program, US Geological Survey, and INEL employees to investigate three issues that had been identified by the INEL Oversight Program at ICPP: (1) the water inventory imbalance at ICPP, (2) the source of water infiltrating into the Tank Farm vault sumps, and (3) the source of water providing potential recharge to perched water bodies underlying ICPP. These issues suggested that water was being lost from the ICPP distribution system. The INEL Oversight Program was concerned that the unaccounted for water at ICPP could be spreading contaminants that have been released over the past 40 years of operations of ICPP, possibly to the Snake ...

1994-01-01

39

Groundwater management in France: the case of the Seine Basin; La gestion des eaux souterraines en France: exemple du bassin de la Seine  

Energy Technology Data Exchange (ETDEWEB)

In France, groundwater usage represents 40 per cent of volumetric use, outside of thermal power plants. Groundwater represents 60 per cent of domestic and public use, 40 per cent in the industrial sector, and is increasing in the agricultural sector where it accounts for 20 per cent. Groundwater withdrawal in France has slightly increased over the last twenty years and benefited the agricultural sector. Availability throughout the territory, the consistency of resupply and natural quality has rendered groundwater a prevailing source for drinking water. Water protection and management is important and led to the adoption of legislative and regulatory measures. The Mining Code (Code minier) allows for exploitation of underground resources starting at 10 metres. The Rural Code (Code rural) mandates the declaration of public utility for water collection for the public. Protection areas are to be provided under the Public Health ...

2001-07-01

40

Design of automatic monitoring network for the water quality management of river basin  

Energy Technology Data Exchange (ETDEWEB)

In designing automatic water quality monitoring networks for a river basin, determination of measurement locations and items is critical to the effectiveness of the total system. In this paper we studied how to decide these two design factors when a monitoring network is designed for the purpose of water quality surveillance and emergency alarm. For measurement locations, candidate sites are chosen based on the intake amount for water supply and the point sources of contamination. Then, detailed locations are decided according to the contaminant flow distance. As for measurement items, characteristics and the accident history of water pollution in the basin must be taken into account. Considering economic aspects, we proposed a two-stage measurement plan: basic components for all locations and selective ones variable for ...

1996-04-30

41

Partitioning Tracers for In-Situ Measurement of Nonaqueous Phase Liquids in the Subsurface - Final Report - 09/15/1996 - 09/14/2000  

Energy Technology Data Exchange (ETDEWEB)

The overall goal of the proposed project is to explore the use of partitioning tracers to characterize dense nonaqueous phase liquids (DNAPLs) in aquifer systems. Bulk-phase partitioning tracers will be investigated to detect and determine DNAPL saturation, while interface partitioning tracers will be investigated to measure the area of the DNAPL-water interface. The specific objectives that will be addressed to accomplish this goal are: (1) Investigate the use of partitioning tracers to detect and determine both the saturation and interfacial area of DNAPLs in saturated porous media. (2) Investigate the effect of rate-limited mass transfer on the transport behavior of partitioning tracers. (3) Investigate the effect of porous-media heterogeneity on the transport behavior of partitioning tracers. (4) Develop and evaluate mathematical models capable of simulating the transport of partitioning tracers in complex systems. This proposal outlines an ...

2000-09-14

42

Status report on the development of a three-dimensional conceptual model for the Hanford Site unconfined aquifer system  

Energy Technology Data Exchange (ETDEWEB)

This report presents the status of development of a three-dimensional conceptual model for the unconfined aquifer system at Hanford. A conceptual model is needed to support development of a realistic three-dimensional numerical model for predicting ground-water flow and the transport of contaminants. The report focuses on developing a hydrogeologic framework, assessing available hydraulic property data, describing flow-system boundaries, and evaluating areal recharge and leakage. Geologic descriptions of samples obtained during well drilling were used to prepare cross sections that correlate relatively continuous layers. The layers were defined based on textural differences that are expected to reflect differences in hydraulic properties. Assigning hydraulic properties to the layers is a critical part of the conceptual model. Available hydraulic property data for the study area were compiled and were correlated with the geologic layers where ...

1992-11-01

43

Mineralogical study of borehole MW-206 Asarco smelter site, Tacoma, Washington  

Energy Technology Data Exchange (ETDEWEB)

The mobility of metals in ground water is an important consideration for evaluating remedial options at the Asarco smelter site. Tacoma, Washington. One factor in assessing metal mobility is the degree of secondary mineralization in a slag-fill aquifer extending into the intertidal zone along the Puget Sound shoreline. Samples of aquifer material were collected for mineralogical analysis from borehole MW-206 at five-foot intervals within the slag fill from 5 to 25 feet below the ground surface, and in the underlying marine sand and gravel at 27 feet. Grab samples of slag fragments with visually apparent secondary minerals were also collected at five intermediate depths between 12 and 19 feet. Samples were analyzed by a variety of techniques including hydride generation/atomic absorption for arsenic concentration, scanning electron microscopy/electron microprobe for mineralogical texture and microanalysis, powder x-ray ...

1998-10-01

44

Constant-pressure charging of a liquid-dominated geothermal reservoir  

Energy Technology Data Exchange (ETDEWEB)

A two-dimensional mathematical model of a fault controlled geothermal reservoir has been developed. Heated water rising in a fault is assumed to charge a reservoir which is overlain by a thin impermeable, thermally conducting cap rock. The mass flow rate or the pressure associated with the charging process at the fault inlet is unknown and can only be estimated. Thus, the pressure in the fault at the bottom of the reservoir is assumed to be prescribed. Quasi-analytic solutions for the distributions of velocity, pressure, and temperature are obtained in the fault-reservoir system for high Rayleigh number flow. In this approximation, the upwelling fluid does not cool off appreciably until it reaches the cold upper boundary of the reservoir and encounters conductive heat loss. The thermal boundary layer, which is thin at the top of the fault, grows outward laterally and occupies the full thickness of the aquifer in the far-field. This study shows ...

1982-03-01

45

Adjoint sensitivity theory for steady-state ground-water flow  

Science.gov (United States)

In this study, adjoint sensitivity theory is developed for equations of two-dimensional steady-state flow in a confined aquifer. Both the primary flow equation and the adjoint sensitivity equation are solved using the Galerkin finite element method. The developed computer code is used to investigate the regional flow parameters of the Leadville Formation of the Paradox Basin in Utah and the Wolcamp carbonate/sandstone aquifer of the Palo Duro Basin in the Texas Panhandle. Two performance measures are evaluated, local heads and velocity in the vicinity of potential high-level nuclear waste repositories. The results illustrate the sensitivity of calculated local heads to the boundary conditions. Local velocity-related performance measures are more sensitive to hydraulic conductivities. The uncertainty in the performance measure is a function of the parameter sensitivity, parameter variance and the correlation between parameters. Given a parameter ...

1983-11-01

46

Satellite-based estimates of groundwater storage variations in large drainage basins with extensive floodplains  

British Library Electronic Table of Contents (United Kingdom)

This study presents monthly estimates of groundwater anomalies in a large river basin dominated by extensive floodplains, the Negro River Basin, based on the synergistic analysis using multisatellite observations and hydrological models. For the period 2003-2004, changes in water stored in the aquifer is isolated from the total water storage measured by GRACE by removing contributions of both the surface reservoir, derived from satellite imagery and radar altimetry, and the root zone reservoir simulated by WGHM and LaD hydrological models. The groundwater anomalies show a realistic spatial pattern compared with the hydrogeological map of the basin, and similar temporal variations to local in situ groundwater observations and altimetry-derived level height measurements. Results highlight th...

2011-01-01

47

Water-level variations and their effects on tree growth and mortality and on the biogeochemical system at the phytoremediation demonstration site in Fort Worth, Texas, 1996-2003  

Science.gov (United States)

In 1996, a field-scale phytoremediation demonstration project was initiated and managed by the U.S. Air Force at a site in western Fort Worth, Texas, using a plantation of 1-year-old stems harvested from branches of eastern cottonwoods during the dormant season (whips) and a plantation of 1-year-old eastern cottonwood seedlings (calipers). The primary objective of the demonstration project was to determine the effectiveness of eastern cottonwoods at reducing the mass of dissolved trichloroethene transported within an alluvial aquifer. The U.S. Geological Survey conducted a study, in cooperation with the U.S. Air Force, to determine water-level variations and their effects on tree growth and mortality and on the biogeochemical system at the phytoremediation site. As part of the study, water-level and water-quality data were collected throughout the duration of the project. This report presents ...

2004-01-01

48

Initial review of the treatment operations at the Installation Logistics Center, Fort Lewis, Washington  

Energy Technology Data Exchange (ETDEWEB)

An initial review was conducted of the current treatment operations for remediation of groundwater contaminated with trichloroethene (TCE) at the Fort lewis Logistics Center. Results from this review indicate the two pump-and-treat systems are effectively containing the TCE plume within the upper unconfined aquifer (Vashon Drift). However, mass balance calculations show the existing treatment systems alone will not accomplish the remedial action objective of cleaning up the aquifer to drinking water standards within 30 years as specified in the Record of Decision (ROD). This conclusion is based on the estimated mass of TCE at the source term (51,000 kg), the calculated mass of TCE in the aquifer (4,900 kg), and the removal rate of the pump-and-treat systems that currently ranges from 324 to 667 kg of TCe per year. Four areas within the TCE plume have been identified where enhancements could be made to ...

1998-07-01

49

Field Investigations in the Tow Study Programme for Coastal Sediment Transport in the Netherlands.  

Science.gov (United States)

Field campaigns were conducted in 1981 and 1982/83 on the Dutch coast near Egmond. Measurements were made of surface elevations, water velocities and sediment concentrations in 3 to 8 surf zone locations and 2 to 5 offshore locations simultaneously. A des...

1985-01-01

50

Assessment of water quality around Jaduguda uranium tailings ponds  

International Nuclear Information System (INIS)

The environmental impacts of uranium mining and milling activities are of great concern in many countries for the last three decades. These impacts range from the creation of massive stockpiles of radioactive and toxic waste rock and sand-like tailings to serious contamination of surface and groundwater with radioactive and toxic pollutants, and releases of conventional, toxic and radioactive air pollutants. Uranium mining is also associated with high concentrations of highly toxic heavy metals, which are a major source of surface and groundwater contamination. Depending upon the hydraulic properties of the fractures involved, contaminated ground water may be transported many miles from its point of origin before feeding into an aquifer. Tailings pond may contaminate the groundwater regime by continuous seepage and leaching of radionuclides and other toxic metals due to interaction of rain water through the tailings ponds. ...

2010-11-15

51

Characterizing partial upwellings ... - Lake Tahoe Validation - NASA  

Science.gov (United States)

measure meteorological variables and bulk water temper- ature. The locations of the buoys are given in Table 1. TB2 and TB3 were moved slightly farther south ...

52

Identification of recharge sources and dating of groundwater using isotope and CFC techniques  

International Nuclear Information System (INIS)

Due to severe drought conditions in Pakistan over the past several years, most of the areas are facing extinction of its potable water reserves and inadequate replenishment of groundwater aquifers. Due to over exploitation, the groundwater flow dynamics is changing and water quality is degrading due to induced infiltration from polluted surface sources. Isotope hydrology is relatively a new discipline having great potential for studying various water-related problems. RIAD, PINSTECH has established analytical facilities for commonly used environmental isotopes and applied to investigate various hydrological problems. This paper briefly describes practical examples on recharge mechanism and dating of groundwater in Lahore and Ziarat areas using isotopes like deuterium (/sup 2/H), Oxygen-18 (/sup 18/O), Tritium (/sup 3/H) and CFCs in water. In Lahore, the areas having different ...

2004-06-07

53

Evaluation of the mobility of an organic pollutant in triphasic conditions; Evaluation de la mobilite d'un polluant organique en conditions triphasiques  

Energy Technology Data Exchange (ETDEWEB)

Soil contamination by liquid organic pollutants represents a serious threat to phreatic ground water. These organic liquids get into the ground and migrate through the porous medium until they finally reach the aquifer. After a critical study of the literature, we listed various existing multiple displacements under three-phase conditions of a disconnected polluting phase that may or not spread over water. The aim of this thesis is to model (at pore scale level) and integrate in the pore network model the various flows that occur when three phases (gas, pollutant and air) are present in a porous medium. The porous medium is supposed completely water-wet. The polluting phase may be connected or not, and the spreading coefficient of the pollutant over water may either be positive or negative. The goal of our study is to obtain macroscopic parameters such as relative permeabilities and ...

2006-10-15

54

Economical assessment of natural gas fired combined cycle power plant with CO{sub 2} capture and sequestration  

Energy Technology Data Exchange (ETDEWEB)

Norway is privileged with extensive resources of natural gas, oil and hydropower. Location of gas fired combined cycle (CC) power plants in Norway offers advantages due to the availability of natural gas from the Norwegian continental shelf and fairly low ambient temperatures, giving high fuel-to-electricity conversion efficiency. The continental shelf provides large storage capacity for CO{sub 2} in deep saline aquifers and in drained gas fields. In this paper the results of extensive work on CO{sub 2} capture carried out during the last years by Statoil in co-operation with several engineering contractors, are presented. The goal has been to develop a commercially viable concept for a combined cycle power plant including CO{sub 2} capture and sequestration. The main concept is based on CO{sub 2} capture from exhaust gas from a combined cycle power plant, using absorption by amine (MEA) solutions. The CO{sub 2} is compressed, transported by ...

2001-07-01

56

Environmental status of Technical Area 49, Los Alamos, New Mexico  

Energy Technology Data Exchange (ETDEWEB)

A series of experiments involving high explosives and radioactive materials were conducted at Los Alamos, New Mexico, primarily to understand certain safety aspects of operational nuclear weapons. The experiments were conducted underground in large diameter holes as deep as 120 ft. The location was selected because it had geologic and hydrologic characteristics that assured complete containment of the experiments and precluded any possible contamination of groundwater. Important features verified by the USGS included the absence of any recharge and about 1200 feet of dry rock above the groundwater aquifer. Residual materials dispersed by detonation of the high explosives remain at the bottom of the experimental holes. The materials of significance from an environmental standpoint include about 40 kg of plutonium, 93 kg of enriched uranium, at least 82 kg of depleted uranium, 13 kg of beryllium, and an undetermined amount of lead. Environmental ...

1987-11-01

57

Decision document for performing a long-term pumping test at the S-3 Site, Oak Ridge Y-12 Plant, Oak Ridge, Tennessee  

Energy Technology Data Exchange (ETDEWEB)

One of the principal problems confronting the remediation of Bear Creek Valley is the cleanup of contaminated groundwater. The S-3 Site is one of the locations in the valley where groundwater is most contaminated, and contamination from the S-3 Site has also caused extensive contamination of downgradient groundwater. This groundwater plume, therefore, has a high priority in the Bear Creek Valley remedial process. Pumping and treating groundwater was identified early in the feasibility study as a likely remedial alternative for the S-3 Site groundwater plume. The hydrology and geochemistry of the plume are extremely complex. There is a high degree of uncertainty in the current understanding of how the aquifer will react physically and chemically to pumping, making evaluation of a pump-and-treat alternative impractical at the present time. Before a pump-and-treat alternative can be evaluated, its technical practicability, effectiveness, and ...

1995-02-01

58

Environmental assessment of the potential effects of aquifer thermal energy storage systems on microorganisms in groundwater  

Energy Technology Data Exchange (ETDEWEB)

The primary objective of this study was to evaluate the potential environmental effects (both adverse and beneficials) of aquifer thermal energy storage (ATES) technology pertaining to microbial communities indigenous to subsurface environments (i.e., aquifers) and the propagation, movement, and potential release of pathogenic microorganisms (specifically, Legionella) within ATES systems. Seasonal storage of thermal energy in aquifers shows great promise to reduce peak demand; reduce electric utility load problems; contribute to establishing favorable economics for district heating and cooling systems; and reduce pollution from extraction, refining, and combustion of fossil fuels. However, concerns that the widespread implementation of this technology may have adverse effects on biological systems indigeneous to aquifers, as well as help to propagate and release pathogenic organisms that enter thee ...

1988-03-01

59

Comparison of results of two dye-tracer tests at the Chestnut Ridge Security Pits, Y-12 Plant, Oak Ridge, Tennessee  

Energy Technology Data Exchange (ETDEWEB)

Personnel from Martin Marietta Energy Systems, Inc. (Energy Systems) manage a closed hazardous waste disposal unit the Chestnut Ridge Security Pits (CRSP), located on the crest of Chestnut Ridge near the Y-12 Plant, Oak Ridge, Tennessee. To investigate the discharge of groundwater from CRSP to springs and streams located along the flanks and base of Chestnut Ridge, an initial dye-tracer study was conducted during 1990. A hydraulic connection was inferred to exist between the injection well (GW-178) on Chestnut Ridge and several sites to the east-northeast, east, and southeast of CRSP. A second dye-tracer study was conducted in 1992 to verify the results of the initial test and identify additional discharge points that are active during wet-weather conditions. No definitive evidence for the presence of dye was identified at any of the 35 locations monitored during the second dye study. Although interpretations of the initial ...

1994-01-01

60

Siemens provides treatment packages for oil production  

British Library Electronic Table of Contents (United Kingdom)

Modec International Inc has selected Siemens Water Technologies to provide sea-water reverse osmosis (SWRO) systems for several floating, production, storage and offloading (FPSO) vessels that are to be operated in deep-water locations. Siemens is also supplying a wastewater reuse system to one of Brazils largest refineries.

2010-01-01

61

Formulation and make-up of simulate dilute water, low ionic content aqueous solution  

Energy Technology Data Exchange (ETDEWEB)

This procedure describes the formulation and make-up of Simulated Dilute Water (SOW), a low-ionic-content water to be used for Activity E-20-50, Long-Term Corrosion Studies. This water has an ionic content which is nominally a factor of ten higher than that of representative waters at or near Yucca Mountain. Representative waters were chosen as J-13 well water [Harrar, 1990] and perched water at Yucca Mountain [Glassley, 1996]. J-13 well water is obtained from ground water that is in contact with the Topopah Spring tuff, which is the repository horizon rock. The perched water is located in the Topopah Spring tuff, but below the repository horizon and above the water table. A nominal times ten higher ionic content was chosen to simulate ...

1997-04-04

62

Sustainable water resources management in Pakistan  

International Nuclear Information System (INIS)

Total river discharge in Pakistan in summer season vary from 3 thousand to 34 thousand cusses (100 thousand Cusses to 1,200 thousand Cusses) and can cause tremendous loss to human lives, crops and property, this causes the loss of most of the flood water in the lower Indus plains to the sea. Due to limited capacity of storage at Tarbela and Mangla Dams on river Indus and Jhelum, with virtually no control on Chenab, Ravi and Sutlej, devastating problems are faced between July and October in the event of excessive rainfall in the catchments. Due to enormous amounts of sediments brought in by the feeding rivers, the three major reservoirs -Tarbela, Mangla and Chashma will lose their storage capacity, by 25 % by the end of the year 2010, which will further aggravate the water-availability situation in Pakistan. The quality of water is also deteriorating due to urbanization and industrialization and agricultural developments. On ...

2004-06-07

63

TheU-Tube: A Novel System for Acquiring Borehole Fluid Samplesfrom a Deep Geologic CO2 Sequestration Experiment  

Energy Technology Data Exchange (ETDEWEB)

A novel system has been deployed to obtain geochemical samples of water and gas, at in situ pressure, during a geologic CO2 sequestration experiment conducted in the Frio brine aquifer in Liberty County, Texas. Project goals required high-frequency recovery of representative and uncontaminated aliquots of a rapidly changing two-phase (supercritical CO2-brine) fluid from 1.5 km depth. The datasets collected, using both the liquid and gas portions of the downhole samples, provide insights into the coupled hydro-geochemical issues affecting CO2 sequestration in brine-filled formations. While the basic premise underlying the U-Tube sampler is not new, the system is unique because careful consideration was given to the processing of the recovered two-phase fluids. In particular, strain gauges mounted beneath the high-pressure surface sample cylinders measured the ratio of recovered brine to supercritical CO2. A quadrupole mass spectrometer provided ...

2005-03-17

64

Adsorption based processes as alternative to common gas conditioning at underground storage facilities using Sorbead; Procedes bases sur l'adsorption comme solution de rechange dans le conditionnement du gaz dans des lieux de stockage souterrains a l'aide de Sorbead  

Energy Technology Data Exchange (ETDEWEB)

The European gas market is continuing to expand due to increased industrial, domestic and power generation demand. As a result of this demand, and the trend toward liberalization of the market, the need for storage of gas is also increasing. One key segment of the large scale storage of gas is underground storage, either in partially depleted gas or oil fields, naturally occurring caverns, aquifers and salt cavities. In most cases the gas produced after storage requires conditioning to meet the water of hydrocarbon dew point specification of the gas transmission system. For that reason export gas from storage will require gas conditioning in order to meet pipeline specifications. Adsorption as a feasible and reliable process will be presented in detail and especially in regards to hydrocarbon dew-pointing compared with other process options. (author)

2000-07-01

65

2008 Data Report: Groundwater Monitoring Program Area 5 Radioactive Waste Management Site  

Science.gov (United States)

This report is a compilation of the groundwater sampling results from the Area 5 Radioactive Waste Management Site (RWMS) including calendar year 2008 results. Each of the three Pilot Wells was sampled on March 11, 2008, and September 10, 2008. These wells were sampled for the following indicators of contamination: pH, specific conductance, total organic carbon, total organic halides, and tritium. Indicators of general water chemistry (cations and anions) were also monitored. Results from all samples collected in 2008 were within the limits established by agreement with the Nevada Division of Environmental Protection for each analyte. These data indicate that there has been no measurable impact to the uppermost aquifer from the Area 5 RWMS. There were no significant changes in measured groundwater parameters compared to previous years. Other information in the report includes an updated Cumulative Chronology for the Area 5 RWMS Groundwater ...

2009-01-13

66

2006 Data Report: Groundwater Monitoring Program Area 5 Radioactive Waste Management Site  

Science.gov (United States)

This report is a compilation of the groundwater sampling results from the Area 5 Radioactive Waste Management Site (RWMS) for calendar year 2006. Pilot wells UE5PW-1, UE5PW-2, and UE5PW-3 were sampled in April and October 2006 for the following indicators of contamination: pH, specific conductance, total organic carbon, total organic halides, and tritium. Indicators of general water chemistry (cations and anions) were also monitored. Results from all samples collected in 2006 were within the limits established by agreement with the Nevada Division of Environmental Protection for each analyte. These data indicate that there has been no measurable impact to the uppermost aquifer from the Area 5 RWMS. There were no significant changes in measured groundwater parameters compared to previous years. Other information in the report includes an updated Cumulative Chronology for the Area 5 RWMS Groundwater Monitoring Program and a brief description of ...

2007-02-01

67

Activity concentration of some anthropogenic radionuclides in the surface marine sediments near the Saudi coast of the Arabian (Persian) Gulf  

British Library Electronic Table of Contents (United Kingdom)

Activity concentrations of some anthropogenic radionuclides (90Sr, 137Cs, 238Pu, 239+240Pu and 241Am) have been measured in the surface of marine sediments along the Saudi coast of the Arabian (Persian) Gulf. The samples were collected at different locations and water depths. The spatial distribution of the concentrations of the measured radionuclides showed a heterogeneous pattern and is independent of location or water depth. The obtained results are discussed and some conclusions are drawn.

2007-01-01

68

Final report of the second dye-tracer test at the Chestnut Ridge Security Pits, Y-12 Plant, Oak Ridge, Tennessee  

Energy Technology Data Exchange (ETDEWEB)

Martin Marietta Energy Systems, Inc. (Energy Systems) manages a closed hazardous waste disposal unit, Chestnut Ridge Security Pits (CRSP), in the form of two trenches and several auger-holes, located on top of the eastern portion of Chestnut Ridge at the Department of Energy (DOE) Oak Ridge Y-12 Plant in Tennessee. The groundwater monitoring system for the unit presently consists of a network of upgradient and downgradient monitor wells. To investigate the discharge of groundwater to springs and streams. An initial dye-tracer study was conducted during the driest part of 1990. The dye was detected at some of the monitoring sites, but verification was necessary due to the proximity of some sites to extraneous dye sources. A second dye-tracer was conducted during the wet weather season. The actual test commenced during the first week of February 1992 with a 4-week baseline monitoring period to determine the inherent variability of the emission spectra within the ...

1992-11-01

69

Eukaryotic Diversity in an Anaerobic Aquifer Polluted with Landfill Leachate?  

UK PubMed Central (United Kingdom)

Eukaryotes may influence pollutant degradation processes in groundwater ecosystems by activities such as predation on bacteria and recycling of nutrients. Culture-independent community profiling and...Full Text Available

2008-07-01

70

Water consumption of a six-year-old river red gum plantation in the Southern Zagros Mountains, Iran  

British Library Electronic Table of Contents (United Kingdom)

Water is the most important limiting factor in the development of arid environments; therefore, optimization of water use is a necessity in desert reclamation projects. Evapotranspiration of a 6-year-old river red gum (Eucalyptus camaldulensis Dehnh.) plantation, located in a sedimentation basin of an artificial recharge of the Gareh Bygone Plain groundwater system in Iran?s southern Zagros Mountains, was studied during a 7-month period. A neutron moisture probe was used to monitor soil water changes in the root zone. Soil water depletion following rapid drainage for blocks receiving relatively high, medium and low volumes of floodwater were 809.6, 312.4, and 203.1 mm, respectively, for a 150-day period. Soil water potential during most of the study period was below ?1.5 MPa. This study pr...

2007-01-01

71

USE OF ENVIRONMENTAL ISOTOPES TO DIFFERENTIATE WATER SOURCES AND CONSTRAIN THE WATER BUDGET AT THE SULPHUR BANK MERCURY MINE, CLEAR LAKE, CALIFORNIA  

Science.gov (United States)

The Sulphur Bank Mercury Mine (SBMM) is a 65 ha site located on the eastern shore of the Oaks Arm of Clear Lake, Lake County, California. Between 1864 and 1957, SBMM was the site of underground and open pit mining operations for S and Hg, coinciding with past and present hot spr...

72

Assessing European potential for geological storage of CO_2 from fossil fuel combustion. The Gestco Project  

International Nuclear Information System (INIS)

Total EU (and Norway) emissions of CO_2 from thermal power generation were some 950 million tonnes in 1990, the Kyoto agreement reference level. An ongoing research project, the GESTCO project, will provide the first documentation that, for the emission sources within the selected key areas, sufficient geological storage capacity is available for at least 30 years and possibly much longer. Cost of energy will obviously increase, but it is anticipated that electricity production cost price will be comparable to that of renewables. It would further have major implications for the European power generating industry which today is totally dominated by fossil fuel combustion with enormous emissions problems. The identification and siting of subsurface CO_2 storage capability can be expected to have considerable effect on the planning for and future siting of fossil fuel plants. In Norway there are plans to build several major, coastally sited, natural gas-fed electricity generating plants. ...

2001-10-01

73

Primary productivity C-14 and algal assay in the study of water pollution effects in the Citarum River and Jatiluhur Reservoir  

International Nuclear Information System (INIS)

Water quality of the Citarum River and the Jatiluhur Reservoir in Indonesia was evaluated using C-14 radioisotope. A close relationship between the abiotic (physical and chemical) and the biotic (algal growth potential, primary productivity, chlorophylla and diversity index of planktonic and benthic macroinvertebrate) parameters was obtained. Algal growth potential to abiotic parameters relationship has the highest correlation coefficient and can be used as a pollution indicator. The other biotic parameters do not show clear relationship with the abiotic parameters. The Citarum water quality is the lowest in those locations which receive human and industrial waste from Bandung and its environment. This water cannot be used for drinking purposes and fishery. The water quality in other locations of the river, however, meets the criteria for agriculture. ...

1983-03-01

74

Aquatic macroinvertebrates and water quality in Sandia Canyon  

International Nuclear Information System (INIS)

In 1990, field studies of water quality and stream macroinvertebrate communities were initiated in Sandia Canyon at Los Alamos National Laboratory. The studies were designed to establish baseline data and to determine the effects of routine discharges of industrial and sanitary waste. Water quality measurements were taken and aquatic macroinvertebrates sampled at three permanent stations within the canyon. Two of the three sample stations are located where the stream regularly receives industrial and sanitary waste effluents. These stations exhibited a low diversity of macroinvertebrates and slightly degraded water quality. The last sample station, located approximately 0.4 km (0.25 mi) downstream from the nearest wastewater outfall, appears to be in a zone of recovery where water quality parameters more closely resemble those found in natural streams in the Los ...

2005-09-01

75

Depleted uranium human health risk assessment, Jefferson Proving Ground, Indiana  

Energy Technology Data Exchange (ETDEWEB)

The risk to human health from fragments of depleted uranium (DU) at Jefferson Proving Ground (JPG) was estimated using two types of ecosystem pathway models. A steady-state, model of the JPG area was developed to examine the effects of DU in soils, water, and vegetation on deer that were hunted and consumed by humans. The RESRAD code was also used to estimate the effects of farming the impact area and consuming the products derived from the farm. The steady-state model showed that minimal doses to humans are expected from consumption of deer that inhabit the impact area. Median values for doses to humans range from about 1 mrem ({plus_minus}2.4) to 0.04 mrem ({plus_minus}0.13) and translate to less than 1 {times} 10{sup {minus}6} detriments (excess cancers) in the population. Monte Carlo simulation of the steady-state model was used to derive the probability distributions from which the median values were drawn. Sensitivity analyses of the steady-state model showed ...

1994-04-29

76

Phytoplankton primary production in a eutrophic cooling water pond  

Energy Technology Data Exchange (ETDEWEB)

The effect of longer ice-free periods on the seasonal variation and total annual values of phytoplankton primary production was considered along with the efficiency and productivity of the phytoplankton communities at different water temperatures by constant light. The studied pond, Vasikkalampi, is located in the town Jvyaskyla in central Finland. The pond is slightly eutrophic and its water is used for cooling purposes by a 35 MW thermal powerplant. The cooling water is taken in the middle of the pond and it returns as heated effluent to the northern part, near the surface, about 100 m from the intake pipe. This circulation and warming of the water keeps the pond open throughout the year except during the coldest weeks in the winter when some parts freeze over. The increase of the water temperature was not sufficient to be optimal for photosynthesis in the ...

1984-01-01

77

Natural radionuclides in drinking water in Argentina  

International Nuclear Information System (INIS)

As part of the national survey to evaluate natural radioactivity in the environment, concentration levels of natural uranium and "2"2"6Ra have been analyzed in over 300 drinking water samples taken from different locations in Argentina. "2"2"6Ra was determined by "2"2"2Rn emanation and liquid scintillation counting, and natural uranium by a fluorimetric procedure. Values ranging from 0.03 to 24 #mu#g.l"-"1 of natural uranium and from 0.06 to 50 #mu#g.l"-"1, were measured on drinking water samples taken from tap water systems and private wells, respectively. Concentrations up to 15 mBq.l"-"1 and to 22 mBq.l"-"1 of "2"2"6Ra were found in drinking water samples taken from tap water systems and private wells, respectively. These values are compared with the reference values accepted for drinking water. Based on the water ...

2000-05-01

78

Spatial water maze learning using celestial cues by the meadow vole, Microtus pennsylvanicus.  

Science.gov (United States)

The Morris water maze is widely used to evaluate to evaluate the spatial learning ability of rodents under laboratory settings. The present study demonstrates that reproductive male meadow voles, Microtus pennsylvanicus, are able to acquire and retain a spatial water maze task using celestial cues. Voles were able to acquire a modified outdoor Morris water maze task over 4 trials per day, whereby they had to learn and remember the location of a submerged hidden platform, using the position of the sun and associated celestial cues. Their proficiency on this task was related to the availability of the celestial cues, with voles displaying significantly poorer spatial navigation on overcast than clear days and when the testing time (and position of the sun and associated celestial cues) was shifted from morning to afternoon. These findings with meadow voles support the ecological relevance of the ...

1994-03-31

79

Final report of the second dye-tracer test at the Chesnut Ridge Security Pits, Y-12 Plant, Oak Ridge, Tennessee  

Energy Technology Data Exchange (ETDEWEB)

Martin Marietta Energy Systems, Inc. (Energy Systems) manages a closed hazardous waste disposal unit, Chestnut Ridge Security Pits (CRSP), in the form of two trenches and several auger-holes, located on top of the eastern portion of Chestnut Ridge at the Department of Energy (DOE) Oak Ridge Y-12 Plant in Tennessee. The groundwater monitoring system for the unit presently consists of a network of upgradient and downgradient monitor wells. To investigate the discharge of groundwater to springs and streams, Energy Systems, through Geraghty and Miller, Inc., conducted an initial dye-tracer study during the driest part of 1990. The dye was detected at some of the monitoring sites, but verification was necessary due to the proximity of some sites to extraneous dye sources. Based on the results of the initial study, Energy Systems recommended to the Tennessee Department of Environment and Conservation (TDEC) in the 1990 Groundwater Quality Assessment Report (GWQAR) (HSW ...

1992-11-01

80

The onset conditions of enhancement of ice accumulation associated with heat-conducting plates located perpendicularly to heat-transfer surfaces; Part 1: Analysis for still water  

Energy Technology Data Exchange (ETDEWEB)

An analytical study of the ice-formation process associated with heat-conducting plates located perpendicularly to isothermally heated and cooled surfaces with some clearance is presented. It is proposed that the onset conditions, which describe whether the ice-volume fraction in a steady state is greater than or less than that without heat-conducting plates, are defined by the dimensionless distances between the heated/cooled walls and the heat-conducting plates. It is shown that the onset conditions are dependent on the pitch and the thickness of the heat-conducting plates and are less dependent on the thermal conductivity of the plates.

1994-07-01

81

Automated method for determining location and magnitude of leaks inside a PWR containment  

Energy Technology Data Exchange (ETDEWEB)

Thermal-hydraulics analysis can be used to determine location and magnitude of leaks inside a pressurized water reactor (PWR) containment, as required by plant technical specifications. The major advantage of this detection method is that it minimizes radiation exposure of maintenance personnel because most of the leak detection process is performed from the control room outside the containment. In addition, such a program allows for the elimination of pipe whip restraints and jet impingement shields, eliminating costs for maintenance of these supports and shields in older plants and lowering construction costs for new plants. Previously, only simple single-node containment models were used for determining leakage magnitude. This paper presents a more sophisticated multinode approach for determining the magnitude and location. The resulting sensitivities to leak can be programmed into the plant's computer system. ...

1986-01-01

82

Geothermal resources of the Wind River Basin, Wyoming  

Energy Technology Data Exchange (ETDEWEB)

The geothermal resources of the Wind River Basin were investigated. Oil-well bottom-hole temperatures, thermal logs of wells, and heat flow data have been interpreted within a framework of geologic and hydrologic constraints. Basic thermal data, which includes the background thermal gradient and the highest recorded temperature and corresponding depth for each basin, is tabulated. Background heat flow in the Wind River Basin is generally insufficient to produce high conductive gradients. Only where hydrologic systems re-distribute heat through mass movement of water will high temperatures occur at shallow depths. Aquifers which may have the confinement and structural characteristics necessary to create such geothermal systems are the Lance/Fort Union, Mesa Verde, Frontier, Muddy, Cloverly, Sundance, Nugget, Park City, Tensleep, Amsden, Madison, Bighorn, and Flathead Formations. Of these the Tensleep Sandstone and Madison Limestone are the most ...

1985-01-01

83

U.S. Department of Energy, Nevada Operations Office, Environmental Monitoring Program: Summary data report - first and second calendar quarters 1994  

International Nuclear Information System (INIS)

During the first and second quarters of 1994 air samples were collected and analyzed from 54 air particulate/halogen sampling stations, 10 noble gas sampling stations and 19 tritiated water vapor sampling stations. Surface water samples were collected and analyzed from 12 open water supply reservoirs, 8 natural springs, 2 wastewater containment ponds and 9 sewage lagoons. Groundwater samples were obtained brom 10 potable and 1 non-potable supply wells, and 8 drinking water consumption points. Ambient radiation levels were measured at 193 locations.

1991-10-31

84

Thermal impact analysis of discharge of circulating cooling water at Daya Bay Nuclear Power Station (GNPS) and Ling'ao Nuclear Power Station (LNPS)  

International Nuclear Information System (INIS)

The circulating cooling water flowrate of GNPS and LNPS is totally about 190 m"3/s. Both stations are located on the western coast of semi-closed Daya Bay. A lot of studies concerning thermal impact of GNPS and LNPS have been carried out since 1987, including mathematical model, physical model, on-site survey and satellite remote sensing, etc. This paper describes the hydrological features of Daya Bay and discharge characteristics of circulating water of GNPS and LNPS, estimates the actual thermal impact of GNPS and LNPS, and indicates that it is advantageous for the dilution of circulating water while the two discharge channels of GNPS and LNPS are combined together towards east

2004-05-01

85

Ecological risk assessment of water environment for Luanhe River Basin based on relative risk model  

British Library Electronic Table of Contents (United Kingdom)

The relative risk model (RRM) was applied in regional ecological risk assessments successfully. In this study, the RRM was developed through increasing the data of risk source and introducing the source?stressor?habitat exposure filter (SSH), the endpoint?habitat exposure filter (EH) and the stressor?endpoint effect filter (SE) to reflect the meaning of exposure and effect more explicit. Water environment which include water quality, water quantity and aquatic ecosystems was selected as the ecological risk assessment endpoints. The Luanhe River Basin located in the North China was selected as model case. The results showed that there were three low risk regions, one medium risk region and two high risk regions in the Luanhe River Basin. The results also indicated habitat destruction was th...

2010-01-01

86

Summary of research on microbiological processes. International Energy Agency Subtask D, final report  

Energy Technology Data Exchange (ETDEWEB)

Storage of thermal energy in aquifers has obvious benefits of saving energy and decreasing the consumption of fossil fuels. However, aquifer thermal energy storage (ATES), which involves groundwater aquifers as the storage medium for heat or chill, impinges on the environment. A literature review of pertinent microbiology publications (Hicks and Stewart, 1988) identified the potential for the interaction of ATES systems and microbiological processes to create a source of infectious diseases and the potential for damage to the environment. In addition, the review identified a potential for microbiological processes to develop conditions that would interfere with the operation of an ATES system. As a result of this research effort, investigators from Finland, Germany, Switzerland, and the United States have examined several ATES systems in operation and have observed that the ATES systems studied do not contribute to ...

1992-09-01

87

Summary of research on microbiological processes  

Energy Technology Data Exchange (ETDEWEB)

Storage of thermal energy in aquifers has obvious benefits of saving energy and decreasing the consumption of fossil fuels. However, aquifer thermal energy storage (ATES), which involves groundwater aquifers as the storage medium for heat or chill, impinges on the environment. A literature review of pertinent microbiology publications (Hicks and Stewart, 1988) identified the potential for the interaction of ATES systems and microbiological processes to create a source of infectious diseases and the potential for damage to the environment. In addition, the review identified a potential for microbiological processes to develop conditions that would interfere with the operation of an ATES system. As a result of this research effort, investigators from Finland, Germany, Switzerland, and the United States have examined several ATES systems in operation and have observed that the ATES systems studied do not contribute to ...

1992-09-01

88

Radon as a tracer of fluids motion in karstic aquifers; Le radon: traceur des circulations fluides dans les aquiferes karstiques  

Energy Technology Data Exchange (ETDEWEB)

Radon ({sup 222}Rn) is a naturally occurring radioactive gas and can be used as a tracer in hydrogeologic studies. Radon concentration measurements have been achieved in ground-air and in groundwater by means of nuclear track detectors to estimate long-term variations. Continuous measurements have been conducted using an electronic automatic probe, to evaluate short-term variations. The results obtained from bore-holes show a good correlation between the aquifer`s structural characteristics and the radon concentrations. The continuous measurements specify rainfall influence. (author). 10 refs., 7 figs., 2 tabs.

1995-04-01

89

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 3, Water heaters, pool heaters, direct heating equipment, and mobile home furnaces  

Energy Technology Data Exchange (ETDEWEB)

This is Volume 3 in a series of documents on energy efficiency of consumer products. This volume discusses energy efficiency of water heaters. Water heaters are defined by NAECA as products that utilize oil, gas, or electricity to heat potable water for use outside the heater upon demand. These are major appliances, which use a large portion (18% on average) of total energy consumed per household (1). They differ from most other appliances in that they are usually installed in obscure locations as part of the plumbing and are ignored until they fail. Residential water heaters are capable of heating water up to 180{degrees}F, although the setpoints are usually set lower.

1993-11-01

90

Marine pastures: a by-product of large (100 megawatt or larger) floating ocean thermal power plants. Progress report, February 1, 1976--April 30, 1976  

Science.gov (United States)

Computer programs have been developed to define the temperature increase which would be needed to bring deep-ocean water into density equilibrium with surface water for locations where data are available. A series of continuous-flow studies on phytoplankton blooms resulting from mixtures of 80 percent deep and 20 percent surface water in 2000-liter concrete culturing vessels (''reactors'') has been completed. A quantitative determination of nutrient utilization and flow through a combined primary and secondary trophic level system has been completed. This study utilized the clam Tapes semidecussata, fed from phytoplankton grown in 80 percent deep and 20 percent surface water. An analysis of the fate of the deep water discharged from a floating OTEC plant indicates that horizontal containment of the resulting deep ...

1976-01-01

91

Applications of cathodic protection for the protection of aqueous and soil corrosion of power plant components  

International Nuclear Information System (INIS)

Power plant components exposed to environments such as water and soil are susceptible to severe corrosion. Many times the effect of corrosion in power plant components can be catastrophic. The problem is aggravated for underground pipelines due to additional factors such as large network of pipelines, proximity to earth mat, high voltage transmission lines, corrosive chemicals, inadequate approach etc. Other components such as condenser water boxes, internals of pipelines, clarifier bridge structures, cooling water inlet gates and pipes etc. which are in continuous contact with water, are subjected to severe corrosion. The nature and locations of all such components are at places which are not accessible for routine maintenance and hence they require long term reliable protection against corrosion. Experience has shown that anti-corrosive coatings are inadequate in preventing ...

1999-11-22

92

Transient impurity transport by automated ion chromatography  

International Nuclear Information System (INIS)

An ion chromatograph has been modified to automatically sample ten liquid water streams from the secondary side of three pressurized water reactors, Calvert Cliffs, Unit One, Rancho Seco and McGuire, Unit 1. Sampling and measurement is semicontinuous with a cycle time of approximately five hours for 10 locations with sensitivities in the range of 0.1 to 0.5 ppb. The efficiency of the condensate polishing system and subsequent transport of sodium, chloride, and sulfate around the system can be readily followed. Sulfate has been shown to have unusual volatility into the steam phase from the steam generator as well as a tendency to pass through the condensate polisher.

1985-03-01

93

Shell coal gasification plant (SCGP-1) environmental performance results  

Energy Technology Data Exchange (ETDEWEB)

Environmental studies in slip-stream process development units at SCGP-1, Shell's advanced coal gasification demonstration plant, located near Houston, Texas, have demonstrated that the gas and water effluents from the Shell Coal Gasification Process (SCGP) are environmentally benign on a broad slate of coals. This report presents the results of those environmental studies. It contains two major subjects, which describe, respectively, the experiments on gas treating and the experiments on water treating. Gas treatment focused on the performance of aqueous methyldiethanolamine (MDEA) and sulfinol-M. 8 refs., 24 figs., 13 tabs.

1991-07-01

94

AAR in concrete of Asejire spillway (OYO state - Nigeria)  

Energy Technology Data Exchange (ETDEWEB)

The Asejire dam at Ibadan, Nigeria was constructed in the late sixties for the purpose of providing water for the city of Ibadan (presently about 4,5 million inhabitants). It is located on the Oshun river approximately fifteen miles from the city. In 1982 cracks were observed on the wing walls and although these continued to develop, no attempt was made at that time to investigate their causes and no repair was carried out. In 1989 the SGI ENGINEERING Group of Geneva, Switzerland was appointed as the consultant for the complete refurbishment of the Asejire water scheme. The consortium Degremont-Poat-Clemessy was awarded the contract for the project. The African Development Bank and the Nigerian Government have provided the loan to finance the project.

1995-12-31

95

Change in runoff characteristics of alpine flowing waters caused by the use of hydroelectric power and its effects on the macro-benthos  

International Nuclear Information System (INIS)

A typical form of change in runoff characteristics caused by the widespread use of hydroelectric power in Switzerland is the intermittent draining (torrent operation). It is the aim of the present work to help elucidate possible consequences of these changes in drain onto the benthobiocoenosis. The study was carried through on the Secklisbach at Oberrickenbach (in the semicanton of Nidwalden) and one of its side streamlets (800m above sea level). The macroinvertebrate coenosis was studied at four locations with similar conditions of drainage basin, population density and topography but varying in the degree of impairment to the draining. There were monthly benthos samples taken using a Surber sampling-device. Results show that the locations not only varied in drain, but also in temperature, this being a consequence of water storage by the power plant. The readings pointed out different values for the ...

96

PWR steam generator chemical cleaning process  

International Nuclear Information System (INIS)

Some of the origins of corrosion encountered in the secondary side of pressurized water reactor steam generators are:-sludge accumulation (a mixture of metal oxides, primarily magnetite and copper) on tube sheet and attack of tube support plates by aggressive impurities leading to denting. Although Electricite de France has not suffered from these problems, it has developed a chemical cleaning process to dissolve corrosion products at both locations. (author).

1986-10-13

97

Experimental verification of an empirical equation for transpired tritium from plant leaves at Tarapur  

International Nuclear Information System (INIS)

The tritium in transpired water of plant leaves from four locations within site area (2=0.92) with that of measured values indicating that at Tarapur, the contribution to TFWT of plant is only from air activity and pick up through soil route is negligible during the period of study. (author)

2010-05-13

98

Comprenhensive Program of Engineering and Geologic Surveys for Designing and Constructing Radioactive Waste Storage Facilities in Hard Rock Massifs  

Energy Technology Data Exchange (ETDEWEB)

Geological, geophysical, and engineering-geological research conducted at the 'Yeniseisky' site obtained data on climatic, geomorphologic, geological conditions, structure and properties of composing rock, and conditions of underground water recharge and discharge. These results provide sufficient information to make an estimate of the suitability of locating a radioactive waste (R W) underground isolation facility at the Nizhnekansky granitoid massif

2002-12-27

99

A precise structure redetermination of nickel ammonium sulfate hexahydrate, Ni(H_2O)_6.2NH_4.2SO_4  

International Nuclear Information System (INIS)

The Ni(H_2O)_6 ion is located at an inversion center. Six octahedral water molecules surround the Ni"I"I ion and form hydrogen bonds with the sulfate groups. Each ammonium group binds to the sulfate groups through hydrogen bonds. (orig.).

1994-05-01

100

Laboratory Evaluation of Base Materials for Neutralization of the Contaminated Aquifer at the F-Area Seepage Basins  

Energy Technology Data Exchange (ETDEWEB)

Laboratory studies were performed to support field-testing of base injection into the F-Area Seepage Basins groundwater. The general purpose of these experiments is to provide information to guide the test of base injection and to identify potential adverse effects.

2001-09-11

101

Shallow subsurface temperatures and some estimates of heat flow from the Colorado Plateau of northeastern Arizona  

Energy Technology Data Exchange (ETDEWEB)

Temperature data to depths of a few hundred meters were obtained from 29 wells in northeastern Arizona; 12 in the region surrounding the San Francisco Volcanic Field, 8 in the Black Mesa area, and 9 in the south-central Colorado Plateau which includes the White Mountains. Although there was evidence for local hydrologic disturbances in many temperature profiles, most wells provided an estimate of the conductive thermal gradient at the site. A few thermal conductivities were measured and were combined with published regional averages for the north-central part of the Colorado Plateau to produce crude estimates of regional heat flux. None of the wells was accessible below the regional aquifers. To these depths, heat flow in the area of the San Francisco Volcanic Field appears to be controlled primarily by regional lateral water movement having a significant downward vertical component of velocity. The mean heat flow of 27 +- 5 mWm/sup -2/ is only ...

1982-01-01

102

Performance assessment for the disposal of low-level waste in the 200 east area burial grounds  

Energy Technology Data Exchange (ETDEWEB)

A performance assessment analysis was completed for the 200 East Area Low-Level Burial Grounds (LLBG) to satisfy compliance requirements in DOE Order 5820.2A. In the analysis, scenarios of radionuclide release from the 200 East Area Low-Level waste facility was evaluated. The analysis focused on two primary scenarios leading to exposure. The first was inadvertent intrusion. In this scenario, it was assumed that institutional control of the site and knowledge of the disposal facility has been lost. Waste is subsequently exhumed and dose from exposure is received. The second scenario was groundwater contamination.In this scenario, radionuclides are leached from the waste by infiltrating precipitation and transported through the soil column to the underlying unconfined aquifer. The contaminated water is pumped from a well 100 m downstream and consumed,causing dose. Estimates of potential contamination of the surrounding environment were developed ...

1996-08-15

103

Fossil fuel decarbonization technology for mitigating global warming  

Energy Technology Data Exchange (ETDEWEB)

It has been understood that production of hydrogen from fossil and carbonaceous fuels with reduced CO{sub 2} emission to the atmosphere is key to the production of hydrogen-rich fuels for mitigating the CO{sub 2} greenhouse gas climate change problem. The conventional methods of hydrogen production from fossil fuels (coal, oil, gas and biomass) include steam reforming and water gas shift mainly of natural gas (SRM). In order to suppress CO{sub 2} emission from the steam reforming process, CO{sub 2} must be concentrated and sequestered either in or under the ocean or underground (in aquifers, or depleted oil or gas wells). Up to about 40% of the energy is lost in this process. An alternative process is the pyrolysis or the thermal decomposition of methane, natural gas (TDM) to hydrogen and carbon. The carbon can either be sequestered or sold on the market as a materials commodity or used as a fuel at a later date under less severe CO{sub 2} ...

1998-09-01

104

2003 Data Report: Groundwater Monitoring Program, Area 5 Radioactive Waste Management Site, Nevada Test Site  

Energy Technology Data Exchange (ETDEWEB)

This report is a compilation of the calendar year 2003 groundwater sampling results from the Area 5 Radioactive Waste Management Site, Nevada Test Site. Wells Ue5PW-1, Ue5PW-2, and Ue5PW-3 were sampled semi-annually for the required analytes: pH, specific conductance, total organic carbon (TOC), total organic halides (TOX), tritium, and major cations/anions. Results from all samples collected in 2003 were within established criteria. These data indicate that there has been no measurable impact to the uppermost aquifer from the Resource Conservation and Recovery Act (RCRA) regulated unit within the Area 5 Radioactive Waste Management Site and confirm that any previous detections of TOC and TOX were false positives. Contamination indicator data are presented in control chart and tabular form with investigation levels indicated. Gross water chemistry data are presented in graphical and tabular form. There were no major changes noted in the ...

2004-02-01

105

Hydrologic Tests at Characterization Wells R-9i, R-13, R-19, R-22, and R-31  

Energy Technology Data Exchange (ETDEWEB)

Hydrologic information is essential for environmental efforts at Los Alamos National Laboratory. Testing at new characterization wells being drilled to the regional aquifer (''R wells'') to improve the conceptual hydrogeologic model of the Pajarito Plateau is providing such information. Drilling has been by air-rotary casing-advance or open-hole methods. Most wells are completed with multiple screens. After their construction, wells were rigorously developed by wire-brushing, bailing, followed by surging, swabbing, or jetting, and finally by pumping. These methods are effective based on field-parameter measurements and comparison of results of hydrologic testing at well R-31 before and after complete well development. We conducted field tests on various zones of saturation penetrated by the R wells to collect data needed for determining hydraulic properties. This document provides details of the design and execution of testing as ...

2003-03-01

106

Long-term Monitoring Plan for the Central Nevada Test Area  

Energy Technology Data Exchange (ETDEWEB)

The groundwater flow and transport model of the Faultless underground nuclear test conducted at the Central Nevada Test Area (CNTA) was accepted by the state regulator and the environmental remediation efforts at the site have progressed to the stages of model validation and long-term monitoring design. This report discusses the long-term monitoring strategy developed for CNTA. Subsurface monitoring is an expensive and time-consuming process, and the design approach should be based on a solid foundation. As such, a thorough literature review of monitoring network design is first presented. Monitoring well networks can be designed for a number of objectives including aquifer characterization, parameter estimation, compliance monitoring, detection monitoring, ambient monitoring, and research monitoring, to name a few. Design methodologies also range from simple hydrogeologic intuition-based tools to sophisticated statistical- and optimization-based tools. When ...

2003-09-02

107

Characterization of an improved disposal site for low and intermediate level waste using Cs-137 deposition profiles  

International Nuclear Information System (INIS)

According to the present concept, the low and intermediate level wastes generated during the Cernavoda NPP operation will be disposed in a near surface repository. The Saligny site, placed in the NPP protected area, has been proposed for their disposal. Geologically, the main components of this site are the quaternary loess, the Precambrian and Pre-quaternary clays, the Eocene and Barremian limestone. Hydrologically, the site can be divided into a vadose zone down to 45-50 m and three distinct aquifers, two of them in the limestone beds and the third in the lenses of sand and limestone existing in the pre-quaternary clay layer. A large research program for site characterization was initiated in 1996. At present, the site characteristics requested for safety analysis have been experimentally measured on soil samples or calculated by different computer programs. Hundreds of experimental values of the density, porosity, hydraulic conductivity, ...

2004-09-09

108

Development of cast-in-place concrete pile installation technique for application in the presence of artesian water; Hiatsu chikasui kasho ni okeru bashouchi kui sekoho no kaihatsu  

Energy Technology Data Exchange (ETDEWEB)

When a rotary excavator is operated at locations where there is artesian water, the aquiclude is fractured under pressure of the artesian water upon the penetration of the pile tip through the aquiclude. Since the equipment is provided with a gap for the reduction of friction between the casing and the excavation face, soil and sand near the pile tip burst forth out of the ground together with underground water through the casing or along the outer circumference of the casing. The newly contrived method introduced here is a double pipe process, in which a large casing (2.0m in diameter) is driven until it lands on the aquiclude, water is injected into the casing for the creation of equilibrium between the artesian head and the head in the casing, and finally a casing as large as the pile (1m in diameter) to be installed is used for the excavation of the artesian ...

1998-11-05

109

Fundamental Elements of Geologic C02 Sequestration in Saline Aquifers  

Energy Technology Data Exchange (ETDEWEB)

Geologic sequestration represents a promising strategy for isolating CO{sub 2} waste streams from the atmosphere. Successful implementation of this approach hinges on our ability to predict the relative effectiveness of subsurface CO{sub 2} migration and sequestration as a function of key target-formation and cap-rock properties, which will enable us to identify optimal sites and evaluate their long-term isolation performance. Quantifying this functional relationship requires a modeling capability that explicitly couples multiphase flow and kinetically controlled geochemical processes. We have developed a unique computational package that meets these criteria, and used it to model CO{sub 2} injection at Statoil's North-Sea Sleipner facility, the world's first saline-aquifer storage site. The package integrates a state-of-the-art reactive transport simulator (NUFT) with supporting geochemical software and databases (SUPCRT92). In our Sleipner ...

2001-11-19

110

Influence of feed water distribution pipe replacement on the water chemistry in the steam generator at Loviisa NPP  

International Nuclear Information System (INIS)

Imatran Voima Oy , (IVO) operates two Russian designed nuclear power plants of type VVER440/213. Unit 1 has been operating since 1977 and unit 2 since 1981. First damage of feed water distribution (FWD) pipes was observed in 1989. In closer examinations FWD-pipe T-connection and distribution nozzles suffered from severe erosion corrosion damage. Similar damages have been found also in other VVER-440 type NPPs. In 1994 the first FWD-pipe was replaced by a new design mounted over the tube bundle instead of the old FWD-pipe, which was located inside the tube bundle. The purpose of this paper is to describe the new FWD-pipe and discuss its effects on the steam generator chemistry. (author)

1998-06-01

111

Barium carbonate sediment sampling for inorganic dissolved carbon using isotope mass ratio spectrometer  

International Nuclear Information System (INIS)

This paperwork explain the method of water sampling to obtain the precipitate of BaCO3 solutions that will be used to analyze 13C from field work in Kelana Jaya, Selangor, Langkawi, Kedah and Taiping, Perak. The sampling involves collecting of water samples for groundwater from boreholes and surface water from canal, river, pond and ex-mining pond from several locations at the study sites. This study also elaborates the instruments and chemicals used. The main purpose of this sampling is to obtain the precipitate of BaCO3 for 13C analysis of dissolved inorganic carbon (DIC). A correct sampling method according to standard is very important to ensure an accurate and precise result. With this, the data from the laboratory analysis result can be fully utilized to make the interpretation of the pollutants movement. (Author)

2009-10-06

112

Subaqueous deposition of reactive mine tailings in an open trench; Deposition subaquatique de residus miniers reactifs dans une fosse a ciel ouvert  

Energy Technology Data Exchange (ETDEWEB)

This poster presentation gave an overview of the subaqueous deposition of reactive mine tailings in the open trench Don Rouyn, located near Rouyn-Noranda, Quebec. The author began by providing a brief background of subaqueous mine tailing storage, and discussed the interest of the Don Rouyn trench. The site was described according to geomorphological and geological aspects. The hydrology conditions existing at the site were mentioned, and the results of the hydrology analysis performed were indicated. Close monitoring of the situation was maintained, and the chemical and physical stability of the tailings were evaluated. The conditions that prevailed both before and after the flooding of the site were explained. Water quality is being monitored, and the results obtained at this site might be used at other locations. 40 figs.

2000-07-01

113

New sealant for nuclear power station premises of emergency location  

International Nuclear Information System (INIS)

When operating a nuclear power plant the necessity arise to eliminate various defects of building constructions, to seal joints and transitional elements. The authors present data concerning the production of a sealing composition made of epoxy resin and used for NPP premises of emergency location. Analytical relations are presented between the properties of the composition (adhesion strength, water absorption and others) and its structure. Physical, mechanical and thermal properties and structural peculiarities are determined in the process of interaction between the filling and binding agents. The composition sustains sealing properties under environmental conditions at he presence of an air - vapour mixture with 160 degrees C"o temperature and 0.3 MPa surplus pressure. (author).

114

Feasibility study for use of the natural convection shutdown heat removal test facility (NSTF) for VHTR water-cooled RCCS shutdown  

International Nuclear Information System (INIS)

In summary, a scaling analysis of a water-cooled Reactor Cavity Cooling System (RCCS) system was performed based on generic information on the RCCS design of PBMR. The analysis demonstrates that the water-cooled RCCS can be simulated at the ANL NSTF facility at a prototypic scale in the lateral direction and about half scale in the vertical direction. Because, by necessity, the scaling is based on a number of approximations, and because no analytical information is available on the performance of a reference water-cooled RCCS, the scaling analysis presented here needs to be 'validated' by analysis of the steady state and transient performance of a reference water-cooled RCCS design. The analysis of the RCCS performance by CFD and system codes presents a number of challenges including: strong 3-D effects in the cavity and the RCCS tubes; simulation of turbulence in flows characterized by natural ...

115

The application of high pH operation to the secondary water chemistry at Genkai Nuclear Power Station  

International Nuclear Information System (INIS)

PWR plants have made efforts to maintain the long-term integrity of the steam generators (SG) by reducing the amount of corrosion products entering the secondary side of the SG. Iron entered the SG can cause several problems: degraded heat conductivity of the SG tubes in locations where iron is deposited, water level oscillations in the SG due to tube support plate hole blockage, and initiation and propagation of inter-granular attacks (IGA) and stress corrosion cracking (SCC). One of the most effective measures, high all-volatile treatment (AVT) chemistry has been applied to actual plants to reduce the flow-accelerated corrosion (FAC) coming from the carbon steel piping. The secondary water chemistry at Genkai NPS 1 and 2 changed, from the Low AVT chemistry to the High AVT chemistry, in November 2006. In this paper, we will describe the results of experiments in applying the use of High pH water in the ...

2009-02-01

116

Restoration of a forested wetland ecosystem in a thermally impacted stream corridor  

Energy Technology Data Exchange (ETDEWEB)

The Savannah River Swamp is a 3,020 Ha forested wetland on the floodplain of the Savannah River and is located on the Department of Energy`s Savannah River Site (SRS). Major impacts to the swamp hydrology occurred with the completion of the production reactors and one coal-fired powerhouse at the SRS in the early 1950`s. Water was pumped from the Savannah River, through secondary heat exchangers of the reactors, and discharged into three of the tributary streams that flow into the swamp. This continued from 1954 to 1988 at various levels. The sustained increases in water volume resulted in overflow of the original stream banks and the creation of additional floodplains. Accompanying this was considerable erosion of the original stream corridor and deposition of a deep silt layer on the newly formed delta. Heated water was discharged directly into Pen Branch and water temperature in ...

1995-09-01

117

Effect of water purification process in radioactive content: analysis on small scale purification plants; Efecto del proceso de purificacion de agua en el contenido radiactivo: analisis en plantas purificadoras a pequena escala  

Energy Technology Data Exchange (ETDEWEB)

Water from small scale purification plants is a low cost alternative for consumers in comparison to the bottled commercial presentations. Because of its low cost per liter, the consumption of this product has increased in recent years, stimulating in turn the installation of purification systems for these small businesses. The purpose of this study was to estimate the efficiency of small scale purification systems located in the cities of Zacatecas and Guadalupe, Zacatecas, to reduce the radioactive content of water. It was measured the total alpha and beta activity in water samples of entry and exit to process, through the liquid scintillation technique. In general it was observed that the process is more efficient in removing alpha that beta activity. The fraction of total alpha activity removed varied between 27 and 100%, while between 0 and 77% of the total beta activity was removed by the analyzed ...

2009-10-15

118

Effect of Suburban Development and Landscape Position on Water Quality in Three Small Watersheds Within the Croton System, New York.  

Science.gov (United States)

Internal hydrological processes in suburban watersheds and their effects on water quality warrant investigation. Instrument clusters (throughfall collectors, suction lysimeters, monitoring wells, and shallow and deep piezometers) were installed at several locations within three small (50 - 70 ha) watersheds (one forested, two with different degrees of suburban development) in the Croton Watershed, southeastern New York. Biweekly and storm samples were analyzed for base cations, selected anions, and DOC over a one-year period. The topographic index (TI) quantified landscape position; flowpath analyses determined degree of development at each cluster, using % impervious cover as the metric. Water quality degradation was observed in sites with medium and high TI values; no such effect was observed along the ridges, i.e., low TI values. At medium TI values, areas with more than 5% impervious had degraded ...

2003-12-01

119

Improvement of local air coolers model in ISAAC  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to assess a new local air coolers model in ISAAC 2.0, as ISAAC 1.0 could model local air coolers only at two locations. In the new model, local air coolers up to twelve locations could be handled. Large LOCA and loss of feed water sequences were selected for the model comparison. Two cases were analyzed with ISAAC 2.0: one with 6 local air coolers in one of the fueling machine room and in the steam generator room, respectively, and the other with 3 local air coolers at both fueling machine room and 6 local air coolers in the steam generator room. The study assumes that the safety systems such as emergency core cooling system, shield cooling system and moderator cooling system are unavailable. According to the ISAAC 2.0 results, the new local air coolers model showed almost no difference between two cases. Also it was found that as the location of LACs increased, the new ...

2004-02-01

120

Geologic setting of the New Production Reactor within the Savannah River Site  

Energy Technology Data Exchange (ETDEWEB)

The geology and hydrology of the reference New Production Reactor (NPR) site at Savannah River Site (SRS) have been summarized using the available information from the NPR site and areas adjacent to the site, particularly the away from reactor spent fuel storage site (AFR site). Lithologic and geophysical logs from wells drilled near the NPR site do not indicate any faults in the upper several hundred feet of the Coastal Plain sediments. However, the Pen Branch Fault is located about 1 mile south of the site and extends into the upper 100 ft of the Coastal Plain sequence. Subsurface voids, resulting from the dissolution of calcareous portions of the sediments, may be present within 200 ft of the surface at the NPR site. The water table is located within 30 to 70 ft of the surface. The NPR site is located on a groundwater divide, and groundwater flow for the shallowest hydraulic zones is predominantly ...

1991-12-31

121

Freeze protection valve for solar heaters  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a solar heater freeze protection valve apparatus comprising in combination: a valve housing; a remote sensor operatively connected to the valve housing from a remote position, the remote sensor including a bulb containing a liquid adapted to compress and expand with the temperature adjacent the bulb; a piston located in the valve body and slidable responsive to expansion and contraction of the liquid in the remote sensor; a first valve element located in the valve housing and attached to the valve piston for movement; a second valve element located in the valve housing and attached to the housing; a first valve seat in the second valve element forming an opening; a second valve seat positioned in a water passageway to allow the flow of fluid when the second valve element is in an open position and to cut off the flow of fluid when the second valve element is in a closed position. ...

1987-07-21

122

Thermal analysis of spent fuel in shuttle station during dry transfer under abnormal cooling conditions for TAPS - 4  

International Nuclear Information System (INIS)

A pair of bundles is placed in a shuttle tube, which is enclosed by a carriage tube kept inside the Shuttle Transfer Station (STS). It takes about 90 minutes for the spent fuel bundles to travel from the reactor channel to Transfer Magazine (TM). Subsequently, the dry transfer operation takes about 4 minutes. An emergency air cooling flow rate of 600 m3/hr is supplied to cool the spent fuel bundles after they reach the STS, following lapse of 4 minutes of spent fuel dry transfer, in case the bundles are not submerged in the light water in STS. A thermal and hydraulic safety analysis has been done to estimate the maximum sheath temperature, if the spent fuel bundles are stuck at a location of 30 mm below the normal location aligned to the TM port. This position of the spent fuel will have least cooling from the emergency cooling airflow. At the same time, the shuttle tube carrying the spent fuel bundle is just above the ...

2006-11-13

123

Fingerprinting using extrolite profiles and physiological data shows sub-specific groupings of Penicillium crustosum strains.  

Science.gov (United States)

Fingerprinting of Penicillium crustosum strains was performed using different phenotypic characteristics. Seven strains of this extremely homogenous species were selected; of these, five originated from geographical locations characterized by low temperatures, and one from a location with a low water activity. Principal component analysis (PCA) was performed using micromorphological data, temperature- and water-dependent growth rates, and extrolite profiles obtained by HPLC analysis. The micromorphological data were less informative, while the growth-rate data were informative only if the strains investigated already showed slight adaptations to the selected external parameter. In contrast, PCA analyses of the extrolite data showed groupings of the strains according to their origins and known physiological differences. These groupings are in full agreement with the clustering obtained by previous ...

2009-04-08

124

Combination offshore drilling rig  

Energy Technology Data Exchange (ETDEWEB)

An offshore drilling rig is described for use in drilling into a formation below a body of water comprising a barge hull having a drilling slot extending inwardly from the peripheral boundary of the barge hull, means for supporting the barge hull in a position above the water, a cantilever structure mounted on the barge hull and movable horizontally with respect to such barge hull, the cantilever structure being so located relative to the drilling slot as to be movable horizontally into a position in vertical alignment with the drilling slot, a derrick and drilling machinery mounted to the cantilever structure and movable into a position above the drilling slot whereby well drilling operations may be conducted through the drilling slot, the cantilever structure also being movable horizontally to a position which locates the derrick and the drilling machinery outboard of the peripheral boundary of the ...

1986-07-29

125

4D experience on Girassol Field block 17, Angola  

Energy Technology Data Exchange (ETDEWEB)

The Girassol field is located in Angolan deep water of Block 17 and consists of large vertically stacked turbidities complexes. The reservoir extends over approximately 200 km{sup 2} and water depth ranges between 1300 and 1400 meters. In that context High Resolution 3D seismic became the most valuable tool to describe and monitor the reservoir. The field development plan took into account, through re-injection of the gas into the reservoir, Total environmental policy imposing the recycling of production gas. Monitoring of this injection was the main reason to shoot the first High Resolution 4D extremely early in the life of field. Despite the complexity of interpretation due to complex fluid situation and pressure effect, the results went way beyond expectations as the 4D images are of very high quality. Data has also been used to update and refine the reservoir flow model as well as to help deciding on the ...

2004-07-01

126

NPD Canada's first nuclear power station  

Energy Technology Data Exchange (ETDEWEB)

This talk reviews the history of the Canadian nuclear-electric program highlighting Canada's first nuclear power station, the Nuclear Power Demonstration or NPD. NPD was commissioned and delivered electricity to Canadian consumers for the first time on june 4, 1962. The Canadian nuclear-electric program is based on the CANDU-PHW (Canadian Deuterium Uranium - Pressurized Heavy Water) concept which was conceived between 1955 and 1958 at the Chalk River Nuclear Laboratory (CRNL) of AECL, located a few miles from Deep River. This talk covers the history of the Canadian nuclear-electric activities dating back to 1939.

2002-07-01

127

Direct dark matter identification with a hybrid detection technique  

CERN Document Server

In the quest to understand the ultimate nature of WIMPs, we propose the use of a hybrid detection technique: cylinders filled with liquefied noble gasses, acting as targets, are immersed inside a tank of Gd-doped ultra-pure water that provides an active and efficient veto against neutrons. The evaluation of the background rejection capabilities and physics potential of this instrument have been carried out through a full GEANT4 simulation, assuming the detector will be located at the Canfranc underground laboratory (in the Spanish Pyrenees). Our results compare very favourably with existing or planned experiments in the field. This technique is scalable and will allow to reach target masses of few tonnes in the next future.

2008-01-01

128

Optimal detector deployment for the CANDU-600 pressurized heavy water reactor  

Science.gov (United States)

An optimal deployment pattern of flux mapping detectors for a Canada uranium-deuterium (CANDU)-600 pressurized heavy water reactor (PHWR) is determined by obtaining an optimal feedback relationship between flux measurements and zone controllers. The reactor core is modeled with a time-dependent two-group, two-dimensional diffusion equation, and flux perturbation are expressed by model expansions. The modal expansion coefficients are used as elements of the state vector representing the system dynamics. An optimal feedback matrix connecting the flux measurement vector to the control vector is derived by minimizing a quadratic performance index involving both the state and control vectors. We obtain the detector effectiveness in terms of the optimal feedback matrix and determine optimal detector locations for the Wolsung Unit 1 reactor in Korea. We have tested the methodology through evaluation of flux maps generated through the CANDU flux ...

1992-01-01

129

Geothermal resource assessment of Idaho Springs, Colorado. Resource series 16  

Energy Technology Data Exchange (ETDEWEB)

Located in the Front Range of the Rocky Mountains approximately 30 miles west of Denver, in the community of Idaho Springs, are a series of thermal springs and wells. The temperature of these waters ranges from a low of 68/sup 0/F (20/sup 0/C) to a high of 127/sup 0/F (53/sup 0/C). To define the hydrothermal conditions of the Idaho Springs region in 1980, an investigation consisting of electrical geophysical surveys, soil mercury geochemical surveys, and reconnaissance geological and hydrogeological investigations was made. Due to topographic and cultural restrictions, the investigation was limited to the immediate area surrounding the thermal springs at the Indian Springs Resort. The bedrock of the region is faulted and fractured metamorphosed Precambrian gneisses and schists, locally intruded by Tertiary age plutons and dikes. The investigation showed that the thermal waters most likely are fault controlled and the ...

1982-01-01

130

Geochemical History of the Dead Sea  

British Library Electronic Table of Contents (United Kingdom)

Graphical Abstract A Southward view of the Dead Sea western coast. The steep western escarpment of the Dead Sea basin, composed mainly of Upper Cretaceous limestone and dolomite, can be seen on the right. Beach terraces left by the shrinking lake run parallel to the shore. The larger part of the area between the present water line and the mountains was still under Dead Sea water just 50?60?years ago. The current fall of the lake?s stand is around 1?m?year?1. Three on-shore sinkholes can be seen in the front of the photo, as well as two submerged ones near its lower left corner. These were caused by dissolution of a Holocene salt layer located tens of meters below the surface, resulting in the collapse of the overlying sediments. The retreat of the Dead Sea in recent years was followed by e...

2009-01-01

131

Advanced Neutron Source: Plant Design Requirements  

Energy Technology Data Exchange (ETDEWEB)

The Advanced Neutron Source will be a new world-class facility for research using hot, thermal, cold, and ultra-cold neutrons. The heart of the facility will be a 330-MW (fission), heavy-water cooled and heavy-water moderated reactor. The reactor will be housed in a central reactor building, with supporting equipment located in an adjoining reactor support building. An array of cold neutron guides will fan out into a large guide hall, housing about 30 neutron research stations. Appropriate office, laboratory, and shop facilities will be included to provide a complete facility for users. The ANS is scheduled to begin operation at the Oak Ridge National Laboratory early in the next decade. This PDR document defines the plant-level requirements for the design, construction, and operation of ANS. It also defines and provides input to the individual System Design Description (SDD) documents. Together, this PDR document and the ...

1990-07-01

132

A mobile remote sensing laboratory for water vapor, trace gas, aerosol, and wind speed measurements  

Energy Technology Data Exchange (ETDEWEB)

The Lawrence Livermore National Laboratory has developed a mobile field laboratory for remote measurement of atmospheric processes and observables that are important in global climate change, dispersal of hazardous materials, and atmospheric pollution. Specific observables of interest are water vapor, trace gases, aerosol size and density, wind, and temperature. The goal is to study atmospheric processes continuously for extended periods in remote field locations. This laboratory has just reached field ready status with sensors for aerosol and trace gas measurement based on established techniques. A development program is underway to enhance the sensor suite with several new techniques and instruments that are expected to significantly extend the state of the art in remote trace gas analysis. The new sensors will be incorporated into the lab during the next two years.

1993-03-19

133

Ultra-high pressure water jet: Baseline report  

International Nuclear Information System (INIS)

The ultra-high pressure waterjet technology was being evaluated at Florida International University (FIU) as a baseline technology. In conjunction with FIU's evaluation of efficiency and cost, this report covers the evaluation conducted for safety and health issues. It is a commercially available technology and has been used for various projects at locations throughout the country. The ultra-high pressure waterjet technology acts as a cutting tool for the removal of surface substrates. The Husky trademark pump feeds water to a lance that directs the high pressure water at the surface to be removed. The safety and health evaluation during the testing demonstration focused on two main areas of exposure. These were dust and noise. The dust exposure was found to be minimal, which would be expected due to the wet environment inherent in the technology, but noise exposure was at a significant level. Further testing for noise is ...

1997-07-01

134

Polycyclic Musks in Water, Sediment, and Fishes from the Upper Hudson River, New York, USA  

British Library Electronic Table of Contents (United Kingdom)

Synthetic musks are used in many consumer products for their pleasant odor and their binding affinity for fabrics. In the early 1990s, polycyclic musks were reported to occur in air, water, sediment, wildlife, and humans from many European countries. Concentrations of polycyclic musks, particularly 1,3,4,6,7,8-hexahydro-4,6,6,7,8,8-hexamethyl-cyclopenta-[?]-2-benzopyr an (HHCB) and 7-acetyl-1,1,3,4,4,6-hexamethyl-1,2,3,4-tetrahydronapthalene (AHTN), have been reported to increase over time in the environment. In this study, concentrations of musks in water, sediment, fish, and mussel were determined from three locations along the upper Hudson River. HHCB and AHTN were detected in water (n?=?5; 3.95?25.8 and 5.09?22.8?ng/L, respectively), sediment (n?=?3; 72.8?388 and 113?544?ng/g, dry weig...

2011-01-01

135

Measurement of snow water storage in the Lake Saperior basin using aerial gamma-ray spectrometry  

International Nuclear Information System (INIS)

A pilot project was started in 1977 over the Lake Superior basin to measure water storage on the land area using aerial gamma-ray spectrometry to provide hydrologic information for forecasting inflow to the lake. Two airborne surveys were made, respectively in November 1977 and March 1978 which provided estimates of the increase in snow water equivalent between these surveys. The basin is located on the Canadian Shield and consequently, the gamma radiation count rate is quite variable. The airborne results are compared with ground measurements on selected flight lines and show generally good agreement. Two equipment calibrations in the Ottawa area provided inconsistent parameter values which are consequently also reflected in the results over the Lake Superior basin. The project has demonstrated to-date that the technique can be developed into an operational system for measuring snow cover water ...

1977-11-01

136

Evaluating the water quality of the microbasins, La Laucha La Lejia and La Rastrojera using macroinvertebrates as biomarkers, Durania municipality, Norte de Santander Department, Colombia  

International Nuclear Information System (INIS)

From June to September 2004 a water research was carried out in six stations that are located at the following microbasins: La Laucha (S1), La Lejia (S2, S3 and S6) and La Rastrojera (S4 and S5). Those microbasins are localized at the Durania municipality in Norte de Santander Department. This study was carried out in order to evaluate water quality at the microbasins above mentioned using macroinvertebrates as bioindicators. For physical, chemical and microbiological parameters a sample was taken at each station. The results were correlated with biologic parameters and it may be concluded that the station 5 closer to the town of Durania is the most polluted by organic matter and that those stations that belong to the ritral zone are less contaminated. The final result showed that the stations 1. 2. 3. 4 and 6 have conditions that can be classified as very clear to clear water and station 5 presents ...

2008-06-01

137

Anticipated climate change impacts on flood characteristics : Moisie River application  

International Nuclear Information System (INIS)

The issue of global warming was discussed with particular reference to the changes that may occur in the hydrological regime within the coming decades in response to predicted changes in climate. Flood events for the 2050 time horizon were investigated along with the consequences on water management and dam safety. Dams operated by Hydro-Quebec are used for flood control, water supply, recreational activities and hydroelectricity. As such, the electric utility relies on methods to evaluate the adaptability of current management plans to climate change. This paper presented the results of a study conducted at the Moisie River watershed, located in northern Quebec. The HSAMI hydrologic model was used to evaluate and compare the occurrences where stream flows and water levels exceed critical values in order to assess the effectiveness of management plans in both current and climate change scenarios. The ...

138

Pre-operational monitoring plan for LIL waste disposal at Saligny  

International Nuclear Information System (INIS)

Developed under the PN II Project 71-009 - MONA, the pre-operational monitoring program of the LIL waste disposal site presented in this paper covers the main elements requested for a continuous improvement of site characterization and safety assessment, as well as for the set up of the baseline data requested for the future operational and post-operational monitoring and surveillance. These elements are: vadose and saturated zones hydrogeology, surface erosion, meteorology and radionuclides content in waters, soil and biota. Pairs of TDR (Time Domain Reflectometry) and pressure sensors, coupled with a meteorological station have been installed on site for the continuously measurement of the water content and matric potential changes due to the climate variations. The data will be used to follow the water balance, the pores water velocity and to calculate the infiltration rate. A new set of erosion ...

2009-10-12

139

Nevada Test Site, 2006 Waste Management Monitoring Report, Area 3 and Area 5 Radioactive Waste Management Sites  

Science.gov (United States)

Environmental monitoring data were collected at and around the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) at the Nevada Test Site. These data are associated with radiation exposure, air, groundwater, meteorology, vadose zone, subsidence, and biota. This report summarizes the 2006 environmental data to provide an overall evaluation of RWMS performance and to support environmental compliance and performance assessment (PA) activities. Some of these data (e.g., radiation exposure, air, and groundwater) are presented in other reports (U.S. Department of Energy, 2006; Warren and Grossman, 2007; National Security Technologies, LLC, 2007). Direct radiation monitoring data indicate that exposure levels around the RWMSs are at or below background levels. Air monitoring data at the Area 3 and Area 5 RWMSs indicate that tritium concentrations are slightly above background levels. There is no detectable man-made radioactivity by gamma spectroscopy, and concentrations of americium ...

2007-06-30

140

Surface-water-resources information for the Ho-Chunk Nation lands and vicinity, Wisconsin  

Science.gov (United States)

The Ho-Chunk Nation is interested in documenting water-quality conditions in streams adjacent to their Reservation lands in Wisconsin and developing management plans to protect these water resources. The Nation uses these waterways for recreation and as a source for food, and therefore, is dedicated to maintaining and restoring their quality. Ho-Chunk lands encompass more than 10,000 acres ranging primarily over 17 counties in Wisconsin. The study areas for this report include streams adjacent to Ho-Chunk Nation residential lands: Potch-Hah-Chee, Sandpillow, Mission, Bluewing, Chakh Hah Chee, Winnebago Heights, Indian Heights, and Ho-Chunk Village. These residential areas, or housing sites, are located along or near the Middle Branch Embarrass, Black, Lemonweir, and Wisconsin Rivers or their tributaries. Water-quality data were compiled and summarized, and basin maps showing land cover and previous ...

2003-01-01

141

Second aquifer storage under discussion. The power supply system of the German Bundestag building in Berlin; Zweiter Aquifer-Speicher im Gespraech. Zur Energieversorgung der Gebaeude des Deutschen Bundestages in Berlin  

Energy Technology Data Exchange (ETDEWEB)

The contribution outlines the current status of the building construction projects for the German Bundestag in Berlin. The following subjects are discussed: Energetic quality of the building, energy supply concept, integrated energy supply system, electric CHP systems, cogeneration (vegetable oil), aquifer storage (heat storage, cold storage), solar energy (photovoltaic energy conversion, thermal solar energy use), economic and ecological aspects. (HW) [Deutsch] Der vorliegende Beitrag gibt einen Ueberblick ueber den aktuellen Stand des Bauvorhabens des Deutschen Bundestages in Berlin. In diesem Zusammenhang wird auf folgende Themen eingegangen: Energetische Gebaeudequalitaet, Energieversorgungskonzept, Energieverbund, stromgefuehrte BHKWs, Kraft-Waerme-Kopplung (Pflanzenoel), Aquiferspeicher (Waermespeicher, Kaeltespeicher), Sonnenergienutzung (Photovoltaik, thermische Solarenergienutzung), Wirtschaftlichkeit und Oekologie. (HW)

1996-12-01

142

Hydrological evaluation of landfill performance (HELP) model assessment of the geology at Los Alamos National Laboratory, Technical Area 54, Material Disposal Area J  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is: (1) conduct HELP model variations in weather data, profile characteristics, and hydraulic conductivities for major rock units; (2) compare and contrast the results of simulations; (3) obtain an estimation of leakage through the landfill from the surface to the aquifer; and (4) evaluate contaminant transport to the aquifer utilizing leakage estimation. The conclusions of this paper are: (1) the HELP model is useful to assess landfill design alternatives or the performance of a pre-existing landfill; (2) model results using site-specific data incorporated into the Weather Generator (Trail 4), varied significantly from generalized runs (Trials 1-3), consequently, models that lack site-specific data should be used cautiously; and (3) data from this study suggest that there will not be significant downward percolation of leachate from the surface of the landfill cap to the aquifer-leachate transport ...

2002-01-01

143

Dosimetric Implications of Atmospheric Dispersal of Tritium Near a Heavy-water Research Reactor Facility  

Energy Technology Data Exchange (ETDEWEB)

An estimate of the tritium dose to the public in the vicinity of the heavy water research reactor facility at AECL-Chalk River Laboratories, Ontario, Canada, has largely been accomplished from analyses on regularly-collected samples of air, precipitation, drinking water and foodstuffs (pasture, fruit, vegetables and milk) and environmental dose models. To increase the confidence with which public doses are calculated, tritium doses were estimated directly from the ratio of tritiated species in urine samples from members of the general public. Single cumulative 24 h urine samples from a few adults living in the vicinity of the heavy-water research reactor facility at Chalk River Laboratories, Canada were collected and analysed for tritiated water and organically bound tritium. The participants were from Ottawa (200 km east), Deep River (10 km west) and Chalk River Laboratories. Tritiated ...

2001-07-01

144

Ventilation test at Mont Terri. Geoelectric monitoring of the opalinus clay desaturation. Phase 2  

Energy Technology Data Exchange (ETDEWEB)

Between December 2001 and May 2004, a ventilation experiment (VE) was performed in the Mont Terri Underground Research Laboratory (URL) and co-financed by the Commission of the European Communities. The objective was to investigate the desaturation of consolidated clay formations in consequence of the ventilation of underground openings of a repository in such a formation. The results of the geoelectric measurements performed in the second phase of the Mont Terri ventilation test can be summarized as follows: Geoelectric tomography has been found suitable for monitoring ventilation-induced saturation changes in the Opalinus clay. During ventilation with dry air a desaturation down to below 50% could be detected in both desaturation cycles. The desaturated zone extends less than 0.5 m into the rock around the microtunnel. During the second resaturation phase, ventilation with humid air led to quick resaturation at the tunnel surface, while resaturation of the rock mass took months. The ...

2008-04-15

145

Ventilation test at Mont Terri. Geoelectric monitoring of the opalinus clay desaturation. Phase 2  

International Nuclear Information System (INIS)

Between December 2001 and May 2004, a ventilation experiment (VE) was performed in the Mont Terri Underground Research Laboratory (URL) and co-financed by the Commission of the European Communities. The objective was to investigate the desaturation of consolidated clay formations in consequence of the ventilation of underground openings of a repository in such a formation. The results of the geoelectric measurements performed in the second phase of the Mont Terri ventilation test can be summarized as follows: Geoelectric tomography has been found suitable for monitoring ventilation-induced saturation changes in the Opalinus clay. During ventilation with dry air a desaturation down to below 50% could be detected in both desaturation cycles. The desaturated zone extends less than 0.5 m into the rock around the microtunnel. During the second resaturation phase, ventilation with humid air led to quick resaturation at the tunnel surface, while resaturation of the rock mass took months. The ...

146

Aquatic macroinvertebrates and water quality of Sandia Canyon, Los Alamos National Laboratory, December 1992--October 1993. Status report  

International Nuclear Information System (INIS)

In the summer of 1990, an accidental spill from the TA-3 Power Plant Environment Tank released more than 3,785 liters of sulfuric acid into upper Sandia Canyon. The Biological Resource Evaluation Team (BRET) of EM-8 at Los Alamos National Laboratory (LANL) has collected aquatic samples from the stream within Sandia Canyon since then. These field studies gather water quality measurements and collect macroinvertebrates from permanent sampling sites. An earlier report by Bennett (1994) discusses previous BRET aquatic studies in Sandia Canyon. This report updates and expands Bennett's initial findings. During 1993, BRET collected water quality data and aquatic macroinvertebrates at five permanent stations within the canyon. The substrates of the upper three stations are largely sands and silts while the substrates of the two lower stations are largely rock and cobbles. The two upstream stations are located near outfalls that ...

2004-06-01

147

An overview of AECL's participation in the Korean Wolsung Tritium Removal Facility Project (WTRF)  

International Nuclear Information System (INIS)

Full text: In heavy-water-moderated power reactors, tritium is primarily produced by neutron capture in deuterium nuclei in the moderator and coolant. For CANDU 6 reactors, the estimated steady-state values are #approx# 3 TBq#centre dot#kg"-"1 D_2O in the moderator and #approx# 74 GBq#centre dot#kg"-"1 D_2O in the coolant. Tritium removal is one option available to reactor operators for use in their heavy water and tritium management strategies. The WTRF is designed to remove tritium from tritiated heavy water in each of the four CANDU units at the Wolsung Site, to immobilize the tritium and to store it on site. The detritiation process is based on three steps: the first one (front-end) involves the transfer of tritium from heavy water to deuterium gas; the second one (enrichment) concentrates the tritium in a cryogenic distillation system to produce essentially pure D_2 and T_2 streams; and in the ...

2007-11-07

148

CFD simulation of steam generator tube rupture thermal-hydraulics  

Energy Technology Data Exchange (ETDEWEB)

Several steam generator tube rupture accidents have occurred at plants in the past. In this paper the Computational Multi-Fluid Dynamics (CMFD) investigation of the horizontal steam generator thermal-hydraulics during the tube rupture accident is performed. A guillotine of a steam generator U-tube is assumed with choked flow from the primary to the secondary side of the steam generator. We have computed water and steam velocity fields, steam volume fraction distribution on the steam generator secondary (shell) side, as well as the swell level increase. The simulation results are a support to the safety analyses of the steam generator tube rupture accident. Numerical simulation is performed with the multidimensional multi-fluid modelling approach. The two-phase flow around steam generator tubes in the bundle is modelled by the porous media approach. Interfacial mass, momentum and energy transfer are modelled with the closure laws. The governing equations are solved ...

2004-07-01

149

Wetlands - A valuable resource for the '90s  

Energy Technology Data Exchange (ETDEWEB)

The nation's wetlands are a valuable resource serving many important natural, industrial, commercial and recreational functions. Wetlands protect shore areas from waves and storms; act as storage areas for flood waters; remove waste from water by trapping soils or silt which settle to the bottom; improve water quality and reduce pollution; are a commercial breeding ground for fish and other foods; and provide space for recreation and habitat for wildlife. They also are located in prime industrial development areas. Recent wetlands losses have caused much public outcry, politicking and regulatory efforts to prevent this trend. During the '90s, the public will see efforts to strike a proper balance regarding wetlands use. Today, wetlands protection is a permitting issue for nearly every major industrial or commercial development and expansion project. Wetlands permit requirements affect ...

1993-04-15

150

Water in chalk reservoirs: 'friend or foe?'  

International Nuclear Information System (INIS)

Most of the petroleum fields in the Norwegian sector of the North Sea are sandstone reservoirs; the oil and gas are trapped in different species of sandstone. But the Ekofisk Field is a chalk reservoir, which really challenges the operator companies. When oil is produced from chalk reservoirs, water usually gets in and the reservoir subsides. The subsidence may be expensive for the oil companies or be used to advantage by increasing the recovery rate. Since 60 per cent of the world's petroleum reserves are located in carbonate reservoirs, it is important to understand what happens as oil and gas are pumped out. Comprehensive studies at the Department of Petroleum Technology and Applied Geophysics at Stavanger University College in Norway show that the mechanical properties of chalk are considerably altered when the pores in the rock become saturated with oil/gas or water under different stress conditions. The processes are ...

151

Superfund record of decision (EPA Region 2): Burnt Fly Bog, Marlboro Township, NJ, September 30, 1998  

Energy Technology Data Exchange (ETDEWEB)

This decision document presents the selected remedial action for the Westerly Wetlands, Northerly Wetlands, and Tar Patch Area at the Burnt Fly Bog Superfund Site. It addresses contaminated soil present on the three remaining contaminated areas on the Site, including the Westerly Wetlands, Northerly Wetlands, and Tar Patch Area. The major components of the selected remedy include: Excavation and off-site disposal of contaminated soil from the Northerly Wetlands; Excavation and off-site disposal of contaminated soil from the Tar Patch Area; Backfilling the excavated area in the Northerly Wetland and reestablishing wetlands; Backfilling the excavated area in the Tar Patch Area and creating wetlands; Provision of additional security fencing around the Westerly Wetlands, and the recording of a Deed Notice for the Westerly Wetlands, Northerly Wetlands, and Tar Patch Area; Monitoring of surface water and sediment in the Westerly Wetlands, surface ...

1999-03-01

152

River ice jams at bridges  

Energy Technology Data Exchange (ETDEWEB)

Ice jamming, known to cause high water levels at even moderate river flows, is described as both the main and least understood source of ice-related bridge damages. This paper describes a joint study by the New Brunswick Department of Transportation, the Department of the Environment, local governments, and the National Water Research Institute, designed to address problems associated with the interaction of ice jams and bridges. The study consists of collecting information at each of four sites in New Brunswick including: historical data on ice jam locations, causes, and water levels; channel bathymetry, width and slope within each study centred at the respective bridge; and documentation of ice conditions throughout the ice season, including measurement of ice cover thickness, observation of breakup mechanisms, times, causes, characteristics and possible impacts of ice jam release. Data analysis will ...

2000-12-01

153

Properly synchronized measurements of droplet sizes for high-pressure intermittent coal-water slurry fuel sprays  

Energy Technology Data Exchange (ETDEWEB)

Experiments were completed to study intermittent coal-water slurry (CWS) fuel sprays injected from an electronically-controlled accumulator injector system. A new synchronization technique was developed using the light extinction signal as a triggering source for the data taking initiation with a laser diffraction particle analyzing (LDPA) technique. This technique allowed measurement of SMDs near the spray tip where the light extinction was low and the data were free from the multiscattering bias. Coal-water slurry fuel with 50% coal loading in mass containing 5 {mu}m mass median diameter coal particulates was considered. A correlation of the SMD with the injection conditions was determined which should show a satisfactory agreement with the measured SMD data. The spray SMD showed an increase with the distance of the axial measurement location and with the ambient gas density, and showed a decrease with increasing ...

1993-12-31

154

Nitrogen Requirements and Balance of Protected Cucumber in Coastal Lebanon  

International Nuclear Information System (INIS)

Protected cultures are widespread along the Lebanese narrow coastline, encouraged by mild winter conditions. Although one of the most intensive production systems, water and nutrients managements are mostly empirical, based on the experience of the grower himself or of his workers. So far, water has been available in Lebanon, but it will become scarce within ten years. The conservation of water quality by a rational addition of nutrients is particularly relevant to protected cultures. This is important as greenhouses are developed on imported shallow soils that could be fragile and highly vulnerable to pollution. Sound management includes the amount and the forms of fertilizers as well as the modality of fertigation. An experiment was conducted during two spring seasons in a location along the northern coast in a typical unheated greenhouse. The cucumber response to two frequencies and modalities of ...

2003-10-01

155

Far-field model of the regional influence of effluent plumes from ocean thermal energy conversion (OTEC) plants  

Science.gov (United States)

Ocean thermal energy conversion (OTEC) plants discharge large volumes of cold water into the upper ocean. A three-dimensional, limited-area model was developed to investigate the regional influence of the far-field effluent plume created by the negatively buoyant discharge. The model was applied to discharges from a 40-MW/sub e/ OTEC plant into coastal waters characterized by various ambient ocean conditions. A typical ambient temperature structure and nutrient distribution, as well as the behavior of the effluent plume itself, were strongly modified by the discharge-induced circulation. Although temperature perturbations in the plume were small, upward entrainment of nutrients from below the thermocline was significant. The regional influence of discharges from an 80-MW/sub e/ OTEC plant, the interactions between the discharges from two adjacent 40-MW/sub e/ OTEC plants, and the effects of coastal boundary and bottom discharge were examined ...

1985-07-01

156

Biological in situ remediation of a former pond for trickling waste water containing explosives  

Energy Technology Data Exchange (ETDEWEB)

WASAG DECON developed a concept for the biological in situ remediation of an TNT-contaminated former seepage pond. This pond is located on the site of an ammunition factory in Lower Saxony. Unit 1982 all the waste water from the production buildings was directed into this pond, including TNT-contaminated water from the flushing of shells. Due to this practice, the sediment of the pond, the underlying soil and the groundwater became contaminated with TNT. The area of the soil contamination adds to abut 2.000 m{sup 2}. The remediation concept includes three steps: 1. Excavation of the most highly contaminated soil with TNT-concentrations above 1000 mg/kg. 2. Reduction of the remaining contamination by a biological in situ treatment using organic and inorganic amendments and mechanical tillage. After about to years of treatment, remediation goals of 50 mg/kg are expected to be reached on most of the area. 3. Contaminations ...

2003-07-01

157

Biological and chemical evaluation of sewage water pollution in the Rietvlei nature reserve wetland area, South Africa  

International Nuclear Information System (INIS)

Macroinvertebrate communities in Rietvlei nature reserve wetland area and their relationship with water quality were studied with the aim to evaluate their use as potential indicators of pollution. Sampling locations were selected to include outlets from swage effluent, agricultural and informal residential runoff. A large increase in nutrient concentrations was observed downstream from discharged treated sewage with an associated decrease in species richness. Bioassays performed included: Daphnia magna, Hydra attenuate, Lactuca sativa, Allium cepa and Pyxicephalus adspersus. The highest percentage of lethality response to a screen (100% concentration) of sampled wetland water by test specimens were observed at the point source input of the Hartbeespoort treated sewage plant. Data generated from the AUSRIVAS method and multitrophic level bioassays revealed the deterioration of the wetland possibly due to factors such as ...

2008-11-01

158

Annual report on monitoring of the unsaturated zone and recharge areas at INEL to the state of Idaho INEL Oversight Committee  

Energy Technology Data Exchange (ETDEWEB)

During the early years of the INEL, the USGS conducted extensive studies (sitewide drilling program) of the geology and hydrology of the area collecting varied data over the years. The unsaturated zone has not received much attention until recently. The studies that have been done are a result of problems or concerns arising from liquid radioactive waste disposal. The TRA facility has the most information published about its waste disposal activities. The ICPP has less data about the unsaturated zone due to the fact that most waste water disposal has been to a well. Little is known about the effect of waste water disposal at the NRF on the unsaturated zone. Essentially no information was found about waste disposal activities at other facilities, primarily because there does not appear to be any reported problems associated with waste water disposal at these locations. The RWMC has received much ...

1992-01-01

159

Annual report on monitoring of the unsaturated zone and recharge areas at INEL to the state of Idaho INEL Oversight Committee  

Energy Technology Data Exchange (ETDEWEB)

During the early years of the INEL, the USGS conducted extensive studies (sitewide drilling program) of the geology and hydrology of the area collecting varied data over the years. The unsaturated zone has not received much attention until recently. The studies that have been done are a result of problems or concerns arising from liquid radioactive waste disposal. The TRA facility has the most information published about its waste disposal activities. The ICPP has less data about the unsaturated zone due to the fact that most waste water disposal has been to a well. Little is known about the effect of waste water disposal at the NRF on the unsaturated zone. Essentially no information was found about waste disposal activities at other facilities, primarily because there does not appear to be any reported problems associated with waste water disposal at these locations. The RWMC has received much ...

1992-12-31

160

Vertical and Horizontal Variations in the Physiological Diversity of the Aerobic Chemoheterotrophic Bacterial Microflora in Deep Southeast Coastal Plain Subsurface Sediments  

UK PubMed Central (United Kingdom)

Aerobic chemoheterotrophic bacteria were isolated from surface soils and coastal plain subsurface (including deep aquifer) sediments (depths to 265 m) at a study site near Aiken, S.C., by plating on...Full Text Available

1989-05-01

161

Manual corrosion  

Energy Technology Data Exchange (ETDEWEB)

In the aim to fight against tubes corrosion of geothermal wells which exploit the aquifer of Dogger reservoir in the Parisian basin, injection of corrosion inhibitors in the geothermal fluid has been generalized since 1989 by using an additive injection tube in the bottom of the well, allowing the protection of the two wells from the geothermal doublet. 3 annexes. 46 refs. 13 tabs. 9 figs.

1994-09-01

162

Characterization of polluted sites. Assessment of pollutant behaviour and transfer in mediums; Caracterisation des sites pollues. L`evaluation du comportement et du transfert des polluants dans les milieux  

Energy Technology Data Exchange (ETDEWEB)

After a presentation of methods and tools for the basic and extensive characterization of polluted sites and the study of evolution and transfer of current organic pollutants in the ground, the example of the rehabilitation of an old Rhone-Poulenc site (at Chauny, France) polluted with metals and arsenic, is described: soil and aquifer diagnosis, risk analysis and determination of migration schemes

1996-12-31

163

Deliberate ignition of hydrogen-air-steam mixtures in condensing steam environments  

Energy Technology Data Exchange (ETDEWEB)

Large scale experiments were performed to determine the effectiveness of thermal glow plug igniters to burn hydrogen in a condensing steam environment due to the presence of water sprays. The experiments were designed to determine if a detonation or accelerated flame could occur in a hydrogen-air-steam mixture which was initially nonflammable due to steam dilution but was rendered flammable by rapid steam condensation due to water sprays. Eleven Hydrogen Igniter Tests were conducted in the test vessel. The vessel was instrumented with pressure transducers, thermocouple rakes, gas grab sample bottles, hydrogen microsensors, and cameras. The vessel contained two prototypic engineered systems: (1) a deliberate hydrogen ignition system and (2) a water spray system. Experiments were conducted under conditions scaled to be nearly prototypic of those expected in Advanced Light Water Reactors (such as the ...

1997-05-01

164

Climate change impacts and adaptation : a Canadian perspective  

International Nuclear Information System (INIS)

This book summarizes the research that has been conducted in Canada over the past five years on the issue of climate change impacts on key sectors such as water resources, agriculture, forestry, fisheries, coastal zones, transportation, and human health and well-being. The book refers to the growing evidence that climate change is occurring. The Intergovernmental Panel on Climate Change (IPCC) believes that these changes have already contributed to increases in annual precipitation, cloud cover and extreme temperatures over the last 50 years. It suggests that it in order to develop an effective strategy for adaptation, it is necessary to understand the vulnerability of each sector to climate change in terms of the nature of climate change, the climatic sensitivity of the region being considered, and the capacity to adapt to the changes. Adaptation will require a reduction in greenhouse gas emissions in order to lower the rate of climate change. Problems associated ...

165

The next wave : kaleidoscope project aims to break the sound barrier of seismic imaging  

Energy Technology Data Exchange (ETDEWEB)

This article discussed a project formed to develop innovative seismic imaging technologies. The Kaleidoscope project aims to accelerate the processing of seismic sound waves by several orders of magnitude using advanced computer-based techniques to reveal oil and gas deposits buried deep in the earth in a manner that is both cost-effective and efficient. It is expected that the technology will be used in deep water applications with massive untapped reserves. The seismic technology will be used to locate hydrocarbons and oil reserves buried 20,000 feet beneath the seabed. It is estimated that the Gulf of Mexico contains 56 billion barrels of oil equivalent worth nearly $6 trillion. However, the reserves are difficult to locate due to the interbedded salt bodies in the subsurface. The project is simultaneously working on both hardware and software applications, and are currently writing the first petascale set of seismic ...

2008-05-15

166

The Argonne boundary layer experiments facility : using minisodars to complement a wind profiler network.  

Energy Technology Data Exchange (ETDEWEB)

The Argonne Boundary Layer Experiments (ABLE) facility, located in south central Kansas, east of Wichita, is devoted primarily to investigations of and within the planetary boundary layer (PBL), including the dynamics of the mixed layer during both day and night; effects of varying land use and land form; the interactive role of precipitation, runoff, and soil moisture; storm development; and energy budgets on scales of 10 to 100 km. Located entirely within the Walnut River watershed, ABLE provides intense measurements within the northeast quadrant (Fig. 1) of the Southern Great Plains (SGP) Cloud and Radiation Testbed (CART) of the Atmospheric Radiation Measurement (ARM) Program (Stokes and Schwarz, 1994). By combining the continuous measurements of ABLE with ancillary continuous measurements of, for example, the ARM and the Global Energy Water cycle Experiment (GEWEX) (Kinster and Shukla, 1990) programs, ABLE provides a ...

1998-06-05

167

Shallow seismic reflection prospecting in Hachiro-kata reclaimed land; Hachirogata kantakuchi ni okeru senbu hanshaho jishin tansa  

Energy Technology Data Exchange (ETDEWEB)

Along the Japan Sea coast in Akita Prefecture and in the vicinity, there exist active fault groups, such as the Kitayuri thrust fault group in the south and Noshiro thrust fault group in the north. It is estimated that there is another fault, running from Akita City located between the above-said two thrust fault groups into the Hachiro-kata reclaimed land, roughly connecting the two thrust fault groups. This third fault is supposed to be related to the hypocenter of Tencho Earthquake of 830, but its location and structural configuration are not known, and it is not known whether it is an active fault, either. Investigations are conducted using S- and P-waves. The greatest problem in the use of P-waves is that there exists a layer in which signal attenuation is high and transmission is anomalously slow. This problem is ascribed to the layer pore water rendered unsaturated though slightly by the inclusion of air bubbles, and ...

1997-05-27

168

Radioactive contamination of fish, shellfish, and waterfowl exposed to Hanford effluents: Annual summaries, 1945--1972. Hanford Environmental Dose Reconstruction Project  

Energy Technology Data Exchange (ETDEWEB)

The objective of the Hanford Environmental Dose Reconstruction Project (HEDR) is to estimate the potential radiation doses received by people living within the sphere of influence of the Hanford Site. A potential critical pathway for human radiation exposure is through the consumption of waterfowl that frequent onsite waste-water ponds or through eating of fish, shellfish, and waterfowl that reside in/on the Columbia River and its tributaries downstream of the reactors. This document summarizes information on fish, shellfish, and waterfowl radiation contamination for samples collected by Hanford monitoring personnel and offsite agencies for the period 1945 to 1972. Specific information includes the types of organisms sampled, the kinds of tissues and organs analyzed, the sampling locations, and the radionuclides reported. Some tissue concentrations are also included. We anticipate that these yearly summaries will be helpful to individuals and ...

1992-07-01

169

Radioactive contamination of fish, shellfish, and waterfowl exposed to Hanford effluents: Annual summaries, 1945--1972  

Energy Technology Data Exchange (ETDEWEB)

The objective of the Hanford Environmental Dose Reconstruction Project (HEDR) is to estimate the potential radiation doses received by people living within the sphere of influence of the Hanford Site. A potential critical pathway for human radiation exposure is through the consumption of waterfowl that frequent onsite waste-water ponds or through eating of fish, shellfish, and waterfowl that reside in/on the Columbia River and its tributaries downstream of the reactors. This document summarizes information on fish, shellfish, and waterfowl radiation contamination for samples collected by Hanford monitoring personnel and offsite agencies for the period 1945 to 1972. Specific information includes the types of organisms sampled, the kinds of tissues and organs analyzed, the sampling locations, and the radionuclides reported. Some tissue concentrations are also included. We anticipate that these yearly summaries will be helpful to individuals and ...

1992-07-01

170

Radioactive contamination of fish, shellfish, and waterfowl exposed to Hanford effluents: Annual summaries, 1945--1972  

International Nuclear Information System (INIS)

The objective of the Hanford Environmental Dose Reconstruction Project (HEDR) is to estimate the potential radiation doses received by people living within the sphere of influence of the Hanford Site. A potential critical pathway for human radiation exposure is through the consumption of waterfowl that frequent onsite waste-water ponds or through eating of fish, shellfish, and waterfowl that reside in/on the Columbia River and its tributaries downstream of the reactors. This document summarizes information on fish, shellfish, and waterfowl radiation contamination for samples collected by Hanford monitoring personnel and offsite agencies for the period 1945 to 1972. Specific information includes the types of organisms sampled, the kinds of tissues and organs analyzed, the sampling locations, and the radionuclides reported. Some tissue concentrations are also included. We anticipate that these yearly summaries will be helpful to individuals and ...

171

Obstacle-induced perturbations on turbulent quantities measured in airflows over the sea  

Energy Technology Data Exchange (ETDEWEB)

An experimental campaign, aiming to investigate the perturbation effects induced by fixed obstacles on turbulence measurements in airflows at the air-sea interface, was carried out at the marine platform of the Italian Navy, located in the harbour of La Spezia (North Ligurian Sea, Italy) on 28., 29., and 30. June 1994. This study was prompted by the ever-growing interest in more reliable estimates of energy, mass, and momentum exchanges between water surfaces and atmosphere, whose measurements are severely limited by the geometrical constraints of floating or fixed platforms where they are installed. Two types of meteorological instruments have been used: fast response (20 and 21 Hz) ultrasonic anemometers and fluxmeters to measure turbulent momentum, sensible, and latent heat fluxes and slow-response sensors (less than 4 Hz and sampled at a rate of 10{sup 2} Hz) to measure average wind and temperature vertical profiles in the perturbed ...

1998-07-01

172

Diaqua[N,Nprime-(o-phenylene)bis(pyridine-2-carboxamidato)-k4N]manganes e(III) perchlorate  

British Library Electronic Table of Contents (United Kingdom)

In the MnIII complex of the title compound, [MnIII(C18H12N4O2)(H2O)2]ClO4, the MnIII atom is coordinated by four N atoms from the bpb2- [1,2-bis(pyridine-2-carboxamido)benzene] ligand located in the equatorial plane and two O atoms of water molecules at axial positions, yielding a distorted MnN4O2 octahedral coordination geometry. The bpb2- ligand is nearly planar, with a maximum deviation of 0.2311 (3) A from the mean plane. The MnIII complex cation and the perchlorate anion, both of which are located on twofold rotation axes, are connected by O-H...O and C-H...O hydrogen bonds into a three-dimensional supramolecular network structure.

2007-01-01

173

An Investigation of the Relationship Between Tritium in Groundwater and the Dendrochronology of Tritium in Trees at the Savannah River Site. Final report  

Energy Technology Data Exchange (ETDEWEB)

This project was supported through ERDA to demonstrate that the temporal distribution of tritium can be documented by the analysis of bound hydrogen in annual tree-ring samples. The project focuses on two sample locations at the Savannah River Site (SRS), a nuclear material production facility located in Aiken, SC. The SRS provided samples of cross-sections from a single tree that were to be pooled together for analysis. Annual tree-rings were identified in each cross-section sample and separated for the period 1954 to 1993. These annual samples were ground and chemically treated to separate the hollocellulose fraction of the wood, then subsequently combusted and the resulting water counting using low-level liquid scintillation counting equipment. Additionally, the ground annual tree-rings were gamma-counted to determine any temporal variation in radionuclide activity and analyzed with x-ray fluorescence to find any ...

1995-03-21

174

Advanced Fuel/Cladding Testing Capabilities in the ORNL High Flux Isotope Reactor  

Energy Technology Data Exchange (ETDEWEB)

The ability to test advanced fuels and cladding materials under reactor operating conditions in the United States is limited. The Oak Ridge National Laboratory (ORNL) High Flux Isotope Reactor (HFIR) and the newly expanded post-irradiation examination (PIE) capability at the ORNL Irradiated Fuels Examination Laboratory provide unique support for this type of advanced fuel/cladding development effort. The wide breadth of ORNL's fuels and materials research divisions provides all the necessary fuel development capabilities in one location. At ORNL, facilities are available from test fuel fabrication, to irradiation in HFIR under either thermal or fast reactor conditions, to a complete suite of PIEs, and to final product disposal. There are very few locations in the world where this full range of capabilities exists. New testing capabilities at HFIR have been developed that allow testing of advanced nuclear fuels and cladding materials ...

2009-09-01

175

Effects on surface hydrology and near-surface hydrogeology of an open repository in Laxemar Results of modelling with MIKE SHE  

Energy Technology Data Exchange (ETDEWEB)

This report presents the methodology and the results from the modelling of an open repository for spent nuclear fuel in Laxemar. Specifically, the present work analyses the hydrological effects of the planned repository during the construction and operational phases when it is open, i.e. air-filled, and hence may cause a disturbance of the hydrological conditions in the surroundings. The numerical modelling is based on the SDM-Site Laxemar MIKE SHE model. The modelling was divided into three steps. The first step was to update the SDM-Site Laxemar model with a new hydrogeological bedrock model. The other main updates were an increase of the depth of the MIKE SHE model domain, enhanced vertical computational resolution and that the drainage of the Aespoe Hard Rock Laboratory was included in the model. The resulting model was used to simulate undisturbed natural conditions. The next step was to describe the open repository conditions, using Laxemar layout D2, by implementing the access ...

2009-10-15

176

The Tropical East Pacific as a Laboratory for Tropical Cyclones  

Science.gov (United States)

The summertime tropical cyclogenesis rate per unit area in the eastern Pacific ocean is arguably higher than in any other location in the world. Many if not most of these cyclones form from African easterly waves which cross Central America into the Pacific. Of order 25% of these waves intensify into cyclones. A significant fraction of east Pacific tropical cyclones undergoes landfall on the Mexican coast. Those which do not, generally dissipate over cold ocean waters north of the east Pacific intertropical convergence zone, often not far from land. The layer of warm ocean water which supports the development of east Pacific cyclones is unusually shallow and is structured by anticyclonic vortices which form by various processes and propagate slowly to the west. These vortices locally deepen the oceanic mixed layer and support stronger convection than their surroundings, possibly promoting cyclogenesis and cyclone ...

2007-05-01

177

The efficiency of coal-fired combined-cycle powerplants  

Energy Technology Data Exchange (ETDEWEB)

Concepts involving combined gas-turbine/steam-turbine power-generation plants, in which the fuel gas for the gas turbine is produced via the gasification of coal, are now extremely advanced. This technology already permits efficiencies of around 50% current development targets view 65% as achievable. In conventional technology, efficiencies are tied to conditions, such as air and cooling-water temperatures, at the particular location. In combined-cycle power plants, the properties of the fuel coal also play an important part. There are, in face, coals which can be more advantageously used in a combined-cycle power plant than in a conventional one. These differences, combined with advantageous concepts for coal-fired combined-cycle power-generating plants, are presented and analyzed. Particular attention is devoted to individual losses occurring at coal conversion, thermodynamic cycles, integration of processes and internal consumptions. 14 ...

1996-12-01

178

The coexistence of fish species in streams: relationships between assemblage attributes and trophic and environmental variables  

British Library Electronic Table of Contents (United Kingdom)

Diet overlap and niche breadth are well-known species traits from trophic ecology that can assist in explaining how species interact and coexist as well as the ecological mechanisms that influence biodiversity. In the present study, we analyzed the relationships between these trophic variables and indicators of resource availability with some attributes of fish assemblages (species richness, Shannon diversity index, evenness, density and individual body size). The physical and chemical characteristics of the biotopes (topography, water quality and conservation of slopes) were examined to identify possible patterns. Monthly sampling using electrofishing was conducted in 2003 along five streams located in the Cuiab? River watershed. The relationships between environmental variables and attri...

2011-01-01

179

The Triton project -- A North Sea subsea challenge  

Energy Technology Data Exchange (ETDEWEB)

Three companies--Amerada Hess Ltd., Shell Expro (a 50/50 joint partnership between Shell and Esso) and Texaco--have joined forces in a project that will combine their expertise. The Triton project will allow three fields (Bittern, Guillemot West and Gullemot Northwest) to be developed simultaneously using subsea technology, with the wellheads on the seafloor and 68 miles (110 km) of flowlines taking oil and gas produced from the fields to a central floating production storage and offloading (FPSO) vessel. These fields are located in the central area of the North Sea, about 118 miles from Aberdeen in 295 ft of water. The paper discusses the development of the fields, subsea technology, technical challenges, laying the pipeline, and project completion.

1998-11-01

180

Sodium hideout studies in steam generator crevices  

International Nuclear Information System (INIS)

The steam generator availability is one of the important problems encountered during the pressurized water nuclear plant operation. Various kinds of corrosion phenomena were observed in the past. These phenomena result from the concentration of impurities mainly in three locations in the steam generators: the tubesheet crevices, the tube support plate crevices, and the sludge pile. Corrections were made in the design and the materials used but a number of steam generators suffer or will suffer from corrosion processes inducing in many cases forcing their replacement. In order to prevent or to retard the corrosions several laboratories have performed experiments to reproduce and to study the corrosion processes. The first step of the degradation is the concentration of chemical species. A method using /sup 24/Na as a radioactive tracer was used to establish the concentration kinetics of caustic which was identified as the major cause of the ...

181

Simulation on stream flow and nutrient loadings in Gucheng Lake, Low Yangtze River Basin, based on SWAT model  

British Library Electronic Table of Contents (United Kingdom)

A distributed watershed hydrologic model soil and water assessment tool (SWAT, 2000 Version) was applied to simulate stream flow and nutrient loadings (including total nitrogen (TN) and total phosphorus (TP)) in Gucheng Lake Basin, which is located in the lower reach of Yangtze River Basin. Model parameters related to stream flow and nutrient loadings were calibrated and validated by the observed value, and the simulation showed that the simulated values were reasonably comparable to the observed data, suggesting the validity of SWAT model. The simulated surface runoff and nutrient yield between two stages, viz. 1981-2000 and 1951-1960, were compared, basically considering land reclamation in the mid-1970s. The result indicated that, the average annual runoff and output of TN and TP in 198...

2009-01-01

182

Restauration of the Clinton site; Restauration du site Clinton  

Energy Technology Data Exchange (ETDEWEB)

Mining of copper and zinc took place at the Clinton Mine located in the Estrie region of Quebec between 1973 and 1975, during which time 115,000 tons of mineral were treated at the Solbec plant. In this poster presentation, the authors provided the background information pertaining to this mine and described the state in which it was in 1994. The pit was covered with good quality water, with a pH of 7,1 and copper and zinc content ranging between 0,1 and 0,6 mg/l, and iron ranging between 0,2 and 1,8 mg/l. The tailings basin drainage was found to have a pH of between 3,6 and 6,1. A program for the characterization of the site was implemented and the concept for the restauration of the Clinton site was developed and implemented. The work carried out at the site is discussed during this presentation as well as the monitoring taking place. 27 figs.

2000-07-01

183

Pre-test report on international round robin analysis of BARC containment (BARCOM) test model  

International Nuclear Information System (INIS)

BARC has organized an international round robin analysis program to carry out the ultimate load capacity assessment of BARC containment (BARCOM) test model. The test model located in BARC facilities Tarapur, is a 1:4 scale representation of 540 MWe pressurized heavy water reactor (PHWR) pre-stressed concrete inner containment structure of Tarapur Atomic Power Station (TAPS) unit 3 and 4. The features of the BARCOM test model and the constitutive data for the pre-test analysis along with the comparison of the results submitted by various participants are described in this pre-test report of the round robin analysis of BARCOM test model

2009-01-01

184

Means and method of balancing multi-cylinder reciprocating machines  

Energy Technology Data Exchange (ETDEWEB)

A virtual balancing axis arrangement is described for multi-cylinder reciprocating piston machines for effectively balancing out imbalanced forces and minimizing residual imbalance moments acting on the crankshaft of such machines without requiring the use of additional parallel-arrayed balancing shafts or complex and expensive gear arrangements. The novel virtual balancing axis arrangement is capable of being designed into multi-cylinder reciprocating piston and crankshaft machines for substantially reducing vibrations induced during operation of such machines with only minimal number of additional component parts. Some of the required component parts may be available from parts already required for operation of auxiliary equipment, such as oil and water pumps used in certain types of reciprocating piston and crankshaft machine so that by appropriate location and dimensioning in accordance with the teachings of the invention, the virtual ...

1985-01-01

185

Landslides on ancient embankments in the Kinki district (Japan): Strong motion seismoscope of the 1596 Keichou-Fushimi earthquake  

British Library Electronic Table of Contents (United Kingdom)

Landslides on ancient embankments, burial mounds of Imashiro-zuka and Nishimotome-zuka, induced by historical earthquakes related to the tectonic movement of active fault systems located between northern Osaka and Kobe, are discussed. The geological conditions of the foundation of the mounds, the lithology, stiffness, and the position of the mound relative to the fault systems, contributed to the collapse of the mounds. Obvious interior structures of landslides revealed the inherent deformation process, and provided significant insight into landslide mechanisms. Rapid increasing pore water pressure was necessary to facilitate sliding along the almost horizontal slip surfaces developed in the main part of the landslide bodies on the Imashiro-zuka mound. Liquefaction analysis using both the ...

2011-01-01

186

Factors affecting the development of the pressure differential in Upper Paleozoic gas reservoirs in the Sulige and Yulin areas of the Ordos Basin, China  

British Library Electronic Table of Contents (United Kingdom)

The Sulige gas field and the Yulin gas field are located in the north of the Ordos Basin. Reservoir pressure in the Sulige area is subnormal, whereas reservoirs in the Yulin area have normal hydrostatic pressure. This paper provides an explanation of this difference. The characteristics of reservoir sediment and formation water chemistry in the gas reservoirs of these two areas were analyzed. The results showed that both reservoirs have good sealing ability. Data of numerical simulation showed that tectonic uplift resulted in a great reduction in formation pressure in the northern Ordos Basin during the late Cretaceous period, and the decrease was greater in the Yulin gas field than in the Sulige gas field. However, because the total hydrocarbon-generating intensity of the Sulige area (<24...

2011-01-01

187

Estimating the erosion and deposition rates in a small watershed by the 137Cs tracing method  

International Nuclear Information System (INIS)

Understanding the erosion and deposition rates in a small watershed is important for designing soil and water conservation measures. The objective of this study is to estimate the net soil loss and gain at points with various land use types and landform positions in a small watershed in the Sichuan Hilly Basin of China by the 137Cs tracing technique. Among various land use types, the order of erosion rate was bare rock > sloping cultivated land > forest land. The paddy field and Caotu (a kind of cultivated land located at the foot of hills) were depositional areas. The erosion rate under different landform was in this order: hillside > saddle > hilltop. The footslope and the valley were depositional areas. The 137Cs technique was shown to provide an effective means of documenting the spatial distribution of soil erosion and deposition within the small watershed.

2009-02-01

188

Effect of wing planform on leading-edge vortex structures  

British Library Electronic Table of Contents (United Kingdom)

Flow visualization experiments are conducted in water tunnel for low aspect ratio cropped wings at low Reynolds number. The experimental results show that the model sweep angle ? influences the formation and development of the leading-edge vortex. For wings with ? =0?, the dominant flow structure is transverse vortex. When ??26?, the dual vortex structure can be observed at some angles of attack, and it is confirmed that the dual vortex is a special structure for flow over low aspect ratio wing at low Reynolds number. For ??56? wings, the dual vortex structure can be observed in a large range of attack angles. Moreover, in comparison with the outer vortex, the breakdown position of the primary vortex is delayed, and the larger the ?, the later the breakdown location at the same angle of at...

2010-01-01

189

Cooperative use of unmanned sea surface and micro aerial vehicles at Hurricane Wilma  

British Library Electronic Table of Contents (United Kingdom)

On Oct. 24, 2005, Hurricane Wilma, a category 5 storm, made landfall at Cape Romano, Florida. Three days later, the Center for Robot-Assisted Search and Rescue at the University of South Florida deployed an iSENYS helicopter and a prototype unmanned water surface vehicle, AEOS-1, to survey damage in parts of Marco Island, 14 km from landfall. The effort was the first known use of unmanned sea surface vehicles (USVs) for emergency response and established their suitability for the recovery phase of disaster management by detecting damage to seawalls and piers, locating submerged debris (moorings and handrails), and determining safe lanes for sea navigation. It provides a preliminary domain theory of postdisaster port and littoral inspection with unmanned vehicles for use by the human-robot ...

2008-01-01

190

Chitons (Mollusca, Polyplacophora) du Pleistocene tardif et de l'Holocene d'Uruguay : paleobiogeographie et reconstruction paleoenvironnementale aux latitudes moyennes de l'Atlantique du sud-ouest  

British Library Electronic Table of Contents (United Kingdom)

Here we present a revision of the fossil record of chitons (Mollusca, Polyplacophora) of Late Pleistocene and Holocene marine deposits of Uruguay and discuss their potential for palaeoenvironmental reconstruction. Chitons were recorded as isolated valves in bivalve- and gastropod-rich assemblages. They are represented by the species Chaetopleura angulata (Spengler), C. isabellei (d'Orbigny), C. asperrima (Gould) and Ischnochiton striolatus (Gray). The last two species are recorded for the first time as fossils not only in Uruguay but also in South America. Exclusively recorded for the Late Pleistocene is the warm water species I. striolatus, whose current southern range limit is located in Santa Catarina, Brazil. Higher temperatures than at present are inferred for the Uruguayan coast duri...

2011-01-01

191

Chemical absorption of carbon dioxide with aqueous sodium hydroxide solution spray  

Energy Technology Data Exchange (ETDEWEB)

Measurements of local mass fluxes of liquid, local number fluxes of the drop and local drop size distributions at various locations in the test column were made for wide ranges of liquid flow rates and gas flow rates. An empirical correlation for the volume mean diameter of the drop at the nozzle exit was proposed. Measurements of the rates of absorption of carbon dioxide from carbon dioxide-air mixtures with water sprays (physical absorption) and aqueous sodium hydroxide sprays (chemical absorption) were made for wide range so fluid flow rates, feed gas concentrations, and initial alkali concentrations. The observed dimensionless rates of absorption were compared with the theoretical values by assuming penetration model with second-order irreversible reaction. 11 refs., 7 figs.

1996-12-31

192

Bioremediation of petroleum-contaminated soil on Kwajalein Island: Microbiological characterization and biotreatability studies  

Energy Technology Data Exchange (ETDEWEB)

Bioremediation technology is being evaluated for use on the Kwajalein Atoll, which is located in the Republic of the Marshall Islands. The study was undertaken by the Oak Ridge National Laboratory (ORNL) on behalf of the US Army Kwajalein Atoll (USAKA). During February of 1991, a team from ORNL and The University of Tennessee (UT) visited the USAKA. In addition to making on-site observations regarding microbial abundance and distribution of petroleum contaminants, they brought back to Oak Ridge various soil and water samples for detailed analyses. This report documents the biological studies of these samples and presents observations made during the period from February to April of 1991 by investigators at ORNL, UT, and the Oak Ridge Associated Universities.

1992-05-01

193

Additional Surveys of Natural Hot Springs in Nakorn Si Thammarat Province  

International Nuclear Information System (INIS)

Having know of four more natural hot spring located in Amphur Phipun, Nakorn Si Thammarat Province, the present investigators went on July 27, 2005 to collect water samples from the four new hot springs in Ampur Phipun, Nakorn Si Thammarat Province. The methods of collection and the determination of radon gas and free-living amoeba were the same as those employed in previous studies. The results revealed radon concentrations higher than the drinking safety limits of 11 Bq/L in specimens from Baan Huaysai Kow (32.30 Bq/L) and Baan Hunob (31.18 Bq/L; both naegleria and acanthamoeba were present in the specimens of the above two sites, whereas only naegleria recovered from Baan Huaysai Kow (Nai Nukul place) and none from Baan Nong Bua.

2005-12-01

194

A parametric design study for a semi/SCR system in Northern North Sea  

British Library Electronic Table of Contents (United Kingdom)

In recent years, offshore reservoirs have been developed in deeper and deeper water environments. Steel catenary risers (SCRs) are being considered in deepwater development such as Northern North Sea. SCRs used in conjunction with a semi-submersible or floating production, storage and offloading (FPSO) in deepwater harsh environments present significant design challenges. The large vertical motions at the semi or FPSO induce severe riser response, which results in difficulty meeting strength and fatigue criteria at the hang off and touch down point locations. To improve the understanding of SCR behaviour and increase the confidence in the design of such systems in deepwater harsh environments, a parametric study on a SCR connected to a semi-submersible was carried out in this paper to deal...

2008-01-01

195

A new method for creating maps of artificially drained areas in large river basins based on aerial photographs and geodata  

British Library Electronic Table of Contents (United Kingdom)

With regard to the creation of river basin plans and programmes of measures according to the EU Water Framework Directive, the importance of model-supported analyses of nutrient inputs into aquatic systems and the localization of source areas is increasing. Especially in lowland regions artificial drainage installations play a major role, but little information exists concerning their location within larger river basins. Therefore, artificially drained lands were identified by interpreting aerial photographs and typical site conditions of the drained plots were derived. A GIS-based approach was then developed, which allows the delineation of artificially drained lands by combining various site conditions like soil properties and land use type. After checking the validity of a derived map f...

2009-01-01

196

Natural resource injury assessment of a crude oil spill  

International Nuclear Information System (INIS)

In January 1994, a 6.7 magnitude earthquake in southern California ruptured a pipeline releasing approximately 4,200 barrels of blended San Joaquin Valley crude oil. A smaller volume entered the Santa Clara River and flowed 25 km downstream to an emergency containment dam. Ruptured water mains and chlorinated discharges from a damaged sewage treatment plant also affected water quality in the river. Quantitative injury assessment studies were initiated within days of the spill and included water/sediment chemistry, benthic macroinvertebrate community analyses and aquatic toxicity tests. Water quality values for TPH, BTEX, and chlorine ranged from nondetectable to 78 mg/l (TPH), nondetectable to 5.4 microg/l (total BTEX constituents) and nondetectable to 600 microg/l (residual chlorine) within 72 hours of the spill. Ammonia concentrations ranged from nondetectable to 12.1 mg/l within 10 days of the spill. ...

1996-11-17

197

Impacts of water erosion on soil physical properties of an Oxisol and an Inceptisol in the Eastern Plains of Colombia  

International Nuclear Information System (INIS)

On the basis of soil losses records during 10 years, three levels of water erosion were established for two soil (Typical Hapludox and Oxic Dystropept) located on high and medium terraces of alluvial flat plain of piedmont in the Eastern Plains in La Libertad Research Center of CORPOICA. Eighteen 3 x 10 m"2 run-off plots were fitted out on a nonrandom arrangement of nine plots by landscape and three soil use and management treatments: zero grazing Brachiaria decumbens pasture for six years, up land rice, soybean and maize rotations for six years and bare soil for 10 years. Soil losses under these treatments allowed to define three degrees of erosion: slight (N_3 moderate (N_2) and severe (N_3) respectively. From each plot soil samples were taken at two depths for physical analyses. infiltration and resistance to cone penetration were measured in the field. Without exception water erosion produced a detrimental effect on ...

1999-12-01

198

Feasibility of /sup 252/Cf source driven neutron noise measurements in water moderated reactors  

Energy Technology Data Exchange (ETDEWEB)

Previous experiments in fast critical assemblies demonstrated a method of determining reactivity from power spectral density measurements with /sup 252/Cf. This method determines reactivity from properties of the reactor only at the subcritical state of interest, thus it does not require a calibration near delayed criticality. The interpretation of the measured data to obtain reactivity does not require knowledge of the relative or absolute values of the source intensity, knowledge of the detection efficiencies, or knowledge of the detection instrumentation frequency responses. An experiment was performed at the Pool Critical Assembly to evaluate the possibility of /sup 252/Cf source driven neutron noise spectral density measurements in light water moderated reactors. This experiment showed that using commercially available detectors, such measurements can be performed in a reasonable time, that is, the measurement of the quantity of interest (the ratio of spectral ...

1980-01-01

199

IMPROVED NATURAL GAS STORAGE WELL REMEDIATION  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the research conducted during Budget Period One on the project ''Improved Natural Gas Storage Well Remediation''. The project team consisted of Furness-Newburge, Inc., the technology developer; TechSavants, Inc., the technology validator; and Nicor Technologies, Inc., the technology user. The overall objectives for the project were: (1) To develop, fabricate and test prototype laboratory devices using sonication and underwater plasma to remove scale from natural gas storage well piping and perforations; (2) To modify the laboratory devices into units capable of being used downhole; (3) To test the capability of the downhole units to remove scale in an observation well at a natural gas storage field; (4) To modify (if necessary) and field harden the units and then test the units in two pressurized injection/withdrawal gas storage wells; and (5) To prepare the project's final report. This report covers activities ...

2001-12-01

200

Use of explosive quick depressurization valves in the SBWR project. Dynamic loads induced by their operation  

International Nuclear Information System (INIS)

In General Electric's design of the Simplified Boiling Water Reactor (SBWR), The depressurization valves (DPV) are installed in the reactor pressure boundary: four are connected to the reactor vessel by means of nozzles, and two more are located on the main steam pipes (one DPV for each line), which act during particular transients and/or loss of coolant accidents (LOCA), consequently providing the reactor vessel with a safe quick depressurization system. Once the vessel is de pressurised, the passive gravity-driven cooling system (GDCS) starts to operate, permitting the injection of water required for continuous core cooling. DPVs are leak tight, with welded flaps, actuated by a [striker[hammer***] which is activated by an explosive mixture. The dynamic loads that open these valves include, in addition to those produced by steam (typical in any thermodynamic transient with open/close valves), other important loads that are ...

201

Unrestricted disposal of minimal activity levels of radioactive wastes: exposure and risk calculations  

Energy Technology Data Exchange (ETDEWEB)

The US Nuclear Regulatory Commission is currently considering revision of rule 10 CFR Part 20, which covers disposal of solid wastes containing minimal radioactivity. In support of these revised rules, we have evaluated the consequences of disposing of four waste streams at four types of disposal areas located in three different geographic regions. Consequences are expressed in terms of human exposures and associated health effects. Each geographic region has its own climate and geology. Example waste streams, waste disposal methods, and geographic regions chosen for this study are clearly specified. Monetary consequences of minimal activity waste disposal are briefly discussed. The PRESTO methodology was used to evaluate radionuclide transport and health effects. This methodology was developed to assess radiological impacts to a static local population for a 1000-year period following disposal. Pathways and processes of transit from the trench to exposed ...

1984-08-01

202

The influence of soil and coppice cycle on the rooting habit of short rotation poplar and willow coppice  

Energy Technology Data Exchange (ETDEWEB)

The increased demand for renewable energy sources has led to large areas of former agricultural land being proposed for short rotation coppice (SRC) establishment. Concerns expressed over the potential impacts of tree roots on buried archaeological evidence led to a study into the rooting habit of SRC. Roots were exposed in trenches dug within a variety of willow and poplar clonal stands grown on brown earth, pelosol, ground-water gley and surface-water gley soils. Root depths and diameters were recorded in each of the 33 trenches. In total, over 18,000 roots were measured on 264 coppice stools. The rotation length, species and stool location within a block were all found to influence the maximum size of root produced. Soil type had some influence on the root number and depth, but the pattern of root distribution down the soil profile was similar for both species. (author)

2004-06-01

203

Safety assessment of South White Rose expansion project  

Energy Technology Data Exchange (ETDEWEB)

Husky Oil Operations Ltd (Husky) is considering the development of the South White Rose Expansion (SWRX) area, located approximately 4 km south of the current Southern Glory Hole (SGH) in approximately 120 m of water. Within the new glory hole, one new drill centre will be constructed with wells tied back and into the SGH manifolds. The SWRX drill centre will comprise three horizontal production wells and two horizontal water injection wells with expansion capacity for eight wells. Husky is intending to submit a Development Plan Amendment to the Canada-Newfoundland and Labrador Offshore Petroleum Board (C-NLOPB) as part of the development. This document presented the results of a study that assessed the potential impact of the new development on existing White Rose safety studies. The study reviewed existing safety studies that were developed for the White Rose project to determine the potential impact of the new SWRX ...

2006-10-05

204

RCRA closure of the Building 3001 Storage Canal  

Energy Technology Data Exchange (ETDEWEB)

The 3001 Storage Canal is located under portions of Buildings 3001 and 3019 at Oak Ridge National Laboratory (ORNL) and has a capacity of approximately 62,000 gallons of water. The term canal has historically been used to identify this structure, however, the canal is an in-ground reinforced concrete structure satisfying the regulatory definition of a tank. From 1943 through 1963, the canal in Building 3001 was designed to be an integral part of the system for handling irradiated fuel from the Oak Ridge Graphite Reactor. Because one of the main initial purposes of the reactor was to produce plutonium for the chemical processing pilot plant in Building 3019, the canal was designed to be the connecting link between the reactor and the pilot plant. During the war years, natural uranium slugs were irradiated in the reactor and then pushed out of the graphite matrix into the system of diversion plates and chutes which directed the fuel into the deep ...

1992-09-01

205

Program plan for development of underground hydroelectric pumped storage technology  

Science.gov (United States)

The Underground Hydroelectric Pumped Storage (UHPS) Program Plan describes in detail the planned activities and expected accomplishments in the conduct of UHPS technology development and validation envisioned in the 1976 to 1990 time frame. This document describes the program objectives, implementation strategy, and management methodology. The concept of underground hydroelectric pumped storage is fully directed to application in the electric utility industry. This technology involves using electrical energy generated by base-load plants during off-peak load periods to drive a high-head pump/turbine which pumps water from a lower reservoir to a substantially elevated (upper) reservoir corresponding to a head of 1000 m or so. The upper reservoir is at ground level and the lower reservoir is below ground. Then, during peak-load periods, water in the upper reservoir is allowed to flow to the lower reservoir which, in turn, drives a hydraulic ...

1976-03-01

206

Numerical simulations of industrial processes involving fluid dynamics, combustion and radiation  

Energy Technology Data Exchange (ETDEWEB)

Moving out of the scientific community research laboratories, computational fluid dynamics (CFD) software packages are now allowing industrials to analyse and optimize industrial processes involving the use of gases, liquids and even some two-phase fluids. Their attractiveness and their impact stems out from the opportunity they offer to bring insight into an existing unit, or even at the design stage, by displaying the spatial distribution of process relevant variables such as temperature, concentration. The filling of the spacing in between a two-layer window is a simple example. This new opportunity of visualisation is at times an unique way, when the process environment is an opaque one, such as liquid metal flowing into a tundish or when measurements of flows may be a long and tedious work, such as flows within water treatment basins. This environment we are to investigate in order to optimize can also be a harsh one, due to its high temperature level for ...

1997-12-31

207

Heavy water reactor facility large-scale containment cooling test program  

Science.gov (United States)

The Heavy Water Reactor Facility (HWRF), as part of the defense-in-depth philosophy to mitigate the effect of design-basis and severe accidents, is equipped with a passive containment cooling system (PCCS). The function of the PCCS is to provide a safety-grade path to the ultimate heat sink for the removal of the reactor coolant system sensible heat and core decay heat. Ambient air enters an annular space between the steel containment shell and the surrounding concrete shield building through inlets in the shield building wall, is heated via natural convection, rises, and exits the building through a chimney located above the containment dome. A test program is in place to access parameters important to the effective operation of the PCCS. This paper focuses on the large-scale tests (LSTs). The objectives of these tests are as follows: (1) demonstrate natural circulation cooling with more prototypic cylinder and dome surface area ratios than ...

1992-01-01

208

Heavy water reactor facility large-scale containment cooling test program  

International Nuclear Information System (INIS)

The Heavy Water Reactor Facility (HWRF), as part of the defense-in-depth philosophy to mitigate the effect of design-basis and severe accidents, is equipped with a passive containment cooling system (PCCS). The function of the PCCS is to provide a safety-grade path to the ultimate heat sink for the removal of the reactor coolant system sensible heat and core decay heat. Ambient air enters an annular space between the steel containment shell and the surrounding concrete shield building through inlets in the shield building wall, is heated via natural convection, rises, and exits the building through a chimney located above the containment dome. A test program is in place to access parameters important to the effective operation of the PCCS. This paper focuses on the large-scale tests (LSTs). The objectives of these tests are as follows: (1) demonstrate natural circulation cooling with more prototypic cylinder and dome surface area ratios than ...

1992-11-15

209

Crystallohydrate forms of trisubstituted uranyl orthophosphate  

International Nuclear Information System (INIS)

The conditions of production and the stability regions have been studied for the following crystallohydrates of trisubstituted uranyl orthophosphates: (UO_2)_3(PO_4)_2x6H_2O, (UO_2)_3(PO_4)_2x4H_2O, and (UO_2)_3(PO_4)_2xH_2O. Their thermal stability has been studied. It is shown that thermal dehydration of high-water hydrates at 220-240 deg C gives (UO_2)_3(PO_4)_2xH_2O. The anion composition and crystal structure of the compound remain constant up to 1000 deg C. The mixture of the composition of U_3O_8xU_3(PO_4)_4 is the final product of decomposition at 1000 deg C. The thermodynamic constants of dehydration processes have been calculated. A conclusion has been made about the polymer structure of the compound in which water is located between the uranylphosphate layers.

210

Assessing the Significance of Above- and Belowground Carbon Allocation of Fast- and Slow-Growing Families of Loblolly Pine - Final Report  

Energy Technology Data Exchange (ETDEWEB)

During this project we experimentally evaluated the below-ground biomass and carbon allocation and partitioning of four different fast- and slow-growing families of loblolly pine located in Scotland County, NC, in an effort to increase the long-term performance of the crop. The trees were subjected to optimal nutrition and control since planting in 1993. Destructive harvests in 1998 and 2000 were used for whole?plant biomass estimates and to identify possible family differences in carbon acquisition (photosynthesis) and water use efficiency. At regular intervals throughout each year we sampled tissues for carbohydrate analyses to assess differences in whole-tree carbon storage. Mini rhizotron observation tubes were installed to monitor root system production and turnover. Stable isotope analysis was used to examine possible functional differences in water and nutrient acquisition of root systems between the various ...

2001-03-01

211

Advanced Neutron Source: Plant Design Requirements. Revision 4  

Energy Technology Data Exchange (ETDEWEB)

The Advanced Neutron Source will be a new world-class facility for research using hot, thermal, cold, and ultra-cold neutrons. The heart of the facility will be a 330-MW (fission), heavy-water cooled and heavy-water moderated reactor. The reactor will be housed in a central reactor building, with supporting equipment located in an adjoining reactor support building. An array of cold neutron guides will fan out into a large guide hall, housing about 30 neutron research stations. Appropriate office, laboratory, and shop facilities will be included to provide a complete facility for users. The ANS is scheduled to begin operation at the Oak Ridge National Laboratory early in the next decade. This PDR document defines the plant-level requirements for the design, construction, and operation of ANS. It also defines and provides input to the individual System Design Description (SDD) documents. Together, this PDR document and the ...

1990-07-01

212

Assessment of soil-gas, soil, and water contamination at the former 19th Street landfill, Fort Gordon, Georgia, 2009-2010  

Science.gov (United States)

Soil gas, soil, and water were assessed for organic and inorganic constituents at the former 19th Street landfill at Fort Gordon, Georgia, from February to September 2010. Passive soil-gas samplers were analyzed to evaluate organic constituents in the hyporheic zone and flood plain of a creek and soil gas within the estimated boundaries of the former landfill. Soil and water samples were analyzed to evaluate inorganic constituents in soil samples, and organic and inorganic constituents in the surface water of a creek adjacent to the landfill, respectively. This assessment was conducted to provide environmental constituent data to Fort Gordon pursuant to requirements of the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. The passive soil-gas samplers deployed in the water-saturated hyporheic zone and flood plain of the creek adjacent to the former landfill indicated the ...

2011-01-01

213

Heat transfer augmentation through wall-shape-induced flow destabilization  

Energy Technology Data Exchange (ETDEWEB)

Experiments on heat transfer augmentation in a rectangular cross-section water channel are reported. The channel geometry is designed to excite normally damped Tollmein-Schlichting modes in order to enhance mixing. In this experiment, a hydrodynamically fully developed flow encounters a test section where one channel boundary is a series of periodic, saw-tooth, transverse grooves. Free shear layers span the groove openings, separating the main channel flow from the circulating vortices contained within each cavity. The periodicity length of the grooves is equal to one-half of the expected wavelength of the most unstable mode. The remaining channel walls are flat, and the channel has an aspect ratio of 10:1. Experiments are performed over the Reynolds number range of 300 to 15,000. Streakline flow visualization shows that the flow is steady at the entrance, but becomes oscillatory downstream of an onset location. This ...

1990-05-01

214

Challenges in commissioning and operation of 'first-of -its- kind' liquid zone control system in TAPP-3 and 4  

International Nuclear Information System (INIS)

Liquid Zone Control (LZC) System is a 'first-of-its-kind' reactivity control device, designed and implemented at TAPP-3 and 4. The system provides zonal and bulk power control. The system consists of fourteen Zone Control Compartments (ZCCs) containing demineralised light water as neutron absorber. Reactivity control is achieved by varying the level of water in the compartments bi-directionally. Six in-core zircaloy assemblies, housing the fourteen ZCCs and an elaborate process system constitute the LZC system. Measurement of water levels in the ZCCs is done using helium bubbler method. Reliability of ZCC water level measurement is of paramount importance. Commissioning and operating the new system trouble free was a challenge, considering the complex nature of the system. While commissioning the system, level measurement of one of the ZCCs (ZCC - 1) was found erratic and inconsistent. Methodologies ...

2006-11-13

215

Assessment of leak detection capability of Candu 6 annulus gas system using moisture injection tests  

Energy Technology Data Exchange (ETDEWEB)

The Candu 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside calandria tube and the annulus between these tubes, which forms a closed loop with CO{sub 2} gas recirculating, is called the Annulus Gas System (AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tbe rupture incident. To judge whether the operator action time is enough or not in the design of Wolsung 2, 3, and 4, the Leak Before Break (LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data for the LBB assessment of Wolsung Units 2, 3, 4, a series of leak detection capability tests was performed by injecting ...

1998-10-01

216

Study on dose distribution of therapeutic proton beams with prompt gamma measurement  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma distribution was compared to the dose distribution measured by an ionization chamber at three different energies of 100, 150, ...

2007-03-15

217

ORNL results for Test Case 1 of the International Atomic Energy Agency`s research program on the safety assessment of Near-Surface Radioactive Waste Disposal Facilities  

Energy Technology Data Exchange (ETDEWEB)

The International Atomic Energy Agency (IAEA) started the Coordinated Research Program entitled ```The Safety Assessment of Near-Surface Radioactive Waste Disposal Facilities.`` The program is aimed at improving the confidence in the modeling results for safety assessments of waste disposal facilities. The program has been given the acronym NSARS (Near-Surface Radioactive Waste Disposal Safety Assessment Reliability Study) for ease of reference. The purpose of this report is to present the ORNL modeling results for the first test case (i.e., Test Case 1) of the IAEA NSARS program. Test Case 1 is based on near-surface disposal of radionuclides that are subsequently leached to a saturated-sand aquifer. Exposure to radionuclides results from use of a well screened in the aquifer and from intrusion into the repository. Two repository concepts were defined in Test Case 1: a simple earth trench and an engineered vault.

1993-07-01

218

Optimization of amide-based inhibitors of soluble epoxide hydrolase with improved water solubility.  

Science.gov (United States)

Soluble epoxide hydrolase (sEH) plays an important role in the metabolism of endogenous chemical mediators involved in the regulation of blood pressure and inflammation. 1,3-Disubstituted ureas with a polar group located on the fifth atom from the carbonyl group of urea function are active inhibitors of sEH both in vitro and in vivo. However, their limited solubility in water and relatively high melting point lead to difficulties in formulating the compounds and poor in vivo efficacy. To improve these physical properties, the effect of structural modification of the urea pharmacophore on the inhibition potencies, water solubilities, octanol/water partition coefficients (log P), and melting points of a series of compounds was evaluated. For murine sEH, no loss of inhibition potency was observed when the urea pharmacophore was modified to an amide function, while for human sEH 2.5-fold decreased ...

2005-05-19

219

Nonlinear stochastic modeling of river dissolved-oxygen  

Energy Technology Data Exchange (ETDEWEB)

An important aspect of water quality modeling is forecasting water quality variables for real-time management and control applications to enhance, maintain and sustain desirable water qualities. The major objective of this research is to develop daily time series models for forecasting river dissolved-oxygen (DO). The modeling approach adopted herein combines deterministic and stochastic concepts for determining properties of the DO process based on time series data and dynamic mechanisms governing the said process. This is accomplished by deriving a general DO stochastic model structure based on a modified Streeter-Phelps DO-BOD dynamic model. Then some types of nonlinear models namely, self-exciting threshold autoregressive-moving average (SETARMA), amplitude-dependent autoregressive (ADAR) and bilinear (BL) models, and the class of linear autoregressive-moving average (ARMA) models are adopted for model identification ...

1984-01-01

220

Modern carbonate sediments and environments of the LaPaz region, Baja California Sur, Mexico  

Energy Technology Data Exchange (ETDEWEB)

The Gulf of California represents one of the most productive and unique marginal seas in the world. The mouth of the Gulf captures warm equatorial water while annual wind patterns assure major upwelling of nutrient-rich water leading to a rich marine biota. These conditions have created a wide array of tropical through warm temperate carbonate environments. The most unusual of these environments is located in the La Paz region of Baja California Sur where tropical-subtropical water temperatures and low rainfall have allowed growth of corals, calcareous red algae, and other shelled invertebrates to form a carbonate bank environment. Sampling and mapping transacts in shallow bays north of La Paz and on the adjacent Espiritu Santo island have revealed a full spectrum of subenvironments including mangrove bordered, terrigenous mud dominated coastal zones, which grade into carbonate tidal flats. In addition, ...

1996-12-31

221

Water Quality and 401 Certification | Clean Water Act | US EPA  

Science.gov (United States)

Clean Water Act You are here: Water Laws & Regulations Policy & Guidance Clean Water Act Water Quality and 401 Certification Water Quality and 401 Certification Water Quality...

2011-08-28

222

Characterization Well R-22 Geochemistry Report  

Energy Technology Data Exchange (ETDEWEB)

This report provides analytical results for groundwater collected during four characterization-sampling rounds conducted at well R-22 from March 2001 through March 2002. Characterization well R-22 was sampled from March 6 through 13, 2001; June 19 through 26, 2001; November 30 through December 10, 2001; and February 27 through March 7, 2002. The goal of the characterization efforts was to assess the hydrochemistry and to determine whether or not contaminants are present in the regional aquifer in the vicinity of the well. A geochemical evaluation of the analytical results for the well is also presented in this report.

2002-09-01

223

Hyperspectral and Multispectral Remote Sensing at Uranium Processing Facilities  

Energy Technology Data Exchange (ETDEWEB)

Many mines and processing facilities are in remote, difficult to access areas, or are in areas where access is limited or restricted for national reasons. In a joint project with Canada Centre for Remote Sensing, the Canadian Safeguards Support Program is investigating utility of multi- and hyperspectral remote sensing for remotely inspecting such site. With a view to eventually using the hyperspectral satellite data now coming available, airborne data over uranium and copper mine tailings and uranium processing facilities in northern Canada were acquired. The objective of this work is to demonstrate that multispectral and hyperspectral data can provide complementary and supplementary information to high-resolution panchromatic imagery for the following safeguards applications: Inspection aids (up-to-date maps of remote locations), change detection, evaluation of member state declarations, monitoring of reactor, mining and processing facility operations, and ...

2003-05-01

224

Dalia integrated production bundle (IPB): an innovative riser solution for deep water fields  

Energy Technology Data Exchange (ETDEWEB)

The Dalia field is located 210 km north west of Luanda (Angola), about 140 km from shore in 1400 meter water-depth. It was the second major discovery out of 15 made in the block 17 operated by Total. The Dalia Umbilical, Flow lines and Risers EPCI Contract was awarded in 2003. The sea-line network to connect and control the 71 wells and 9 manifolds consist of the following: 40 km of insulated pipe in pipe (12 inches into 17 inches) production flow lines; 45 km of 12 inches water and gas injection lines; 6 off 1.7 km flexible water and gas injection risers; 8 off 1.65 km flexible Integrated Production Bundle (IPB) risers; 75 km of control umbilicals. The flow assurance and associated insulation requirement of the production transport system was one of the main challenges of the project. With a crude temperature of 45 deg C at the wellhead and the required minimum temperature of 35 deg C on arrival at the ...

2008-07-01

225

Snow Survey & Water Supply | NRCS  

Science.gov (United States)

Programs & Services Technical Resources Land Use Soils Water Snow Survey & Water Supply Water Management Water Quality Watersheds Wetlands Air Plants & Animals Energy Climate...

2011-08-21

226

Asia - Goddard Earth Science Data and Information Services Center ...  

Science.gov (United States)

Sep 9, 2009 ... You are here: GES DISC Home Geomorphology from Space By Location Landforms by Location: Asia. Info. Landforms by Location: Asia. KEY, ASIA ...

227

The creep and intergranular cracking behavior of Ni-Cr-Fe-C alloys in 360 degree C water  

International Nuclear Information System (INIS)

Mechanical testing of controlled-purity Ni-xCr-9Fe-yC alloys at 360 C revealed an environmental enhancement in IG cracking and time-dependent deformation in high purity and primary water over that exhibited in argon. Dimples on the IG facets indicate a creep void nucleation and growth failure mode. IG cracking was primarily located at the interior of the specimen and not necessarily linked to direct contact with the environment. Controlled potential CERT experiments showed increases in IG cracking as the applied potential decreased, suggesting that hydrogen is detrimental to the mechanical properties. It is proposed that the environment, through the presence of hydrogen, enhances IG cracking by enhancing the matrix dislocation mobility. This is based on observations that dislocation-controlled creep controls the IG cracking of controlled-purity Ni-xCr-9Fe-yC in argon at 360 C and grain boundary cavitation and sliding results that show the ...

1995-03-26

228

Radiological dose assessment for the decontaminated concrete removed from 183-H solar evaporation basins at the Hanford site, Richland, Washington  

Energy Technology Data Exchange (ETDEWEB)

Potential maximum radiation dose rates over a 1,000-year time horizon were calculated for exposure to the decontaminated concrete removed from the 183-H Solar Evaporation Basins at the Hanford Site, Richland, Washington. The RESRAD computer code, Version 5.62, which implements the methodology described in the US Department of Energy`s manual for developing residual radioactive material guidelines, was used in this evaluation. Currently, the concrete is not being used. Four potential exposure scenarios were developed for the land area where the decontaminated concrete will be stored. In Scenario A industrial use of the land is assumed; in Scenario B recreational use of the land is assumed; in Scenario C residential use of the land is assumed; and in Scenario D (a plausible but unlikely land-use scenario), the presence of a subsistence farmer in the immediate vicinity of the land is assumed. For Scenarios A and B, water used for drinking is assumed to be surface ...

1997-01-01

229

Postremediation dose assessment for the former Alba Craft Laboratory site, Oxford, Ohio  

Energy Technology Data Exchange (ETDEWEB)

Potential maximum radiation dose rates were calculated for the former Alba Craft Laboratory site in Oxford, Ohio, which was involved in machining of uranium metal in the 1950s for the U.S. atomic energy program. The site is not currently being used. The residual radioactive material guidelines (RESRAD) computer code, which implements the methodology described in the US Department of Energy`s (DOE`s) manual for establishing residual radioactive material guidelines, was sued in this evaluation. Three potential land use scenarios were considered for the former Alba Craft site; the scenarios vary with regard to the type of site use, time spent at the site by the exposed individual, and sources of food consumed. Scenario A (a possible land use scenario) assumed industrial use of the site; Scenario B (a likely future land use scenario) assumed residential use of the site; and Scenario C (a possible but unlikely land use scenario) assumed the presence of a resident farmer. For scenario A, it ...

1996-04-01

230

Low Frequency Phased Array Techniques for Crack Detection in Cast Austenitic Piping Welds: A Feasibility Study  

Energy Technology Data Exchange (ETDEWEB)

Studies conducted at the Pacific Northwest National Laboratory (PNNL) in Richland, Washington have focused on developing and evaluating the reliability of nondestructive testing (NDT) approaches for coarse-grained stainless steel reactor components. The objective of this work is to provide information to the United States Nuclear Regulatory Commission (NRC) on the utility, effectiveness and limitation of NDT techniques as related to inservice testing of primary system piping components in pressurized water reactors. We examined cast stainless steel pipe specimens containing thermal and mechanical fatigue cracks located close to the weld roots and having inner and outer diameter surface geometrical conditions that simulate several water reactor primary piping configurations. In addition, segments of vintage centrifugally cast piping were examined to characterize the inherent acoustic noise and scattering caused by grain ...

2007-01-01

231

Liuhua 11-1 development -- Design and fabrication considerations for the FPSO Nanhai Sheng Li  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the development, design, and fabrication of the crude oil process facilities, and the conversion of an existing tanker for use at the Liuhua 11-1 Field. Over a 16-month period spanning 1994 and 1995, Amoco Orient Petroleum Company, and partners, China Offshore Oil Nanhai East Corporation (CONHE), and Kerr-McGee China Petroleum Ltd., converted a crude oil tanker originally built in 1975 to the Nanhai Sheng Li, the floating production, storage and offloading (FPSO) facility for the Liuhua 11-1 Field. The FPSO will process up to 65,000 BOPD produced from 20 subsea wells located 1.7 miles away. In addition to the processing facilities for produced oil and water, the FPSO has a processed crude oil storage capacity of 715,000 bbls. The ship`s propulsion system was removed during the conversion, because the FPSO is permanently moored at site by means of a 10-point, ``soft`` mooring. The mooring system was designed to survive the ...

1996-12-31

232

Integrated experimental test program on waterhammer pressure pulses and associated structural responses within a feedwater sparger  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the methods and systems as utilized in an integrated experimental thermohydraulic/mechanics analysis test program on waterhammer pressure pulses within a revised feedwater sparger of a Loviisa generation VVER-440-type reactor. This program was carried out in two stages: (1) measurements with a strictly limited set of operating parameters at Loviisa NPP, and (2) measurements with the full set of operating parameters on a test article simulating the revised feedwater sparger. The experiments at Loviisa NPS served as an invaluable source of information on the nature of waterhammer pressure pulses and structural responses. These tests thus helped to set the objectives and formulate the concept for series of tests on a test article to study the water hammer phenomena. The heavily instrumented full size test article of a steam generator feedwater sparger was placed within a pressure vessel simulating the steam generator. The feedwater sparger was ...

1997-12-31

233

Global climate change response program. Part 1. Potential effects of global change on chlorophyll alpha concentrations in a southwestern desert reservoir: Las Vegas Bay, Lake Mead, Nevada. Part 2. Simulated impacts of a double CO2 climate on the location of the thermocline in Lake Mead, Nevada. Final report  

Energy Technology Data Exchange (ETDEWEB)

Three algal bioassay experiments were conducted from March 1992 through September 1993 in an area of Lake Mead that has experienced problems associated with severe nutrient enrichment. The first experiment determined the effects of elevated CO2 (700 ppm) (2xCO2), vs ambient CO2 on the natural algal assemblage without nutrient enrichment. The second experiment determined the effects of 2xCO2 on nutrient enriched bioassays and if nutrients were limiting. The third experiment examined elevated temperatures and 2xCO2. Nested climate models were used to predict changes in water temperatures and thermocline development in Las Vegas Bay. The lake model predicted an increase in mean water temperatures of 1.8 deg under a 2xCO2 scenario. A thermocline definition of 1 deg. C change per 2-m depth was applied to water temperatures developed by a lake model coupled to nested general circulation and regional-scale atmospheric models in ...

1997-01-01

234

Characteristics and formation mechanism of Permian Shanxi tight gas reservoir of Changbei gas field, Ordos Basin  

Energy Technology Data Exchange (ETDEWEB)

This paper discussed the lithological characteristics of tight gas reservoirs, including the diagenetic characteristics, diagenetic environment and diagenetic sequence. The link between porosity, the sedimentary environment, lithology, diagenesis and basin tectonics was examined in order to determine how tight reservoirs were formed. The study focused on the Changbei gas field located in Yishan Slope of the Ordos Basin in China. The main pay zone reservoir is the Upper Paleozoic Lower Permian Shanxi sandstone which lies at a depth of 2700-2950 m. This low porosity, low permeability tight gas reservoir was deposited in a coal bearing acid environment which controlled the diagenesis sequence. The early carbonate cement was not well developed because the original pore water was acidic with non saturated calcium carbonate. However, compaction has significantly reduced the original pore and pore volume. The acidic environment caused large amounts of ...

2010-07-01

235

Failure location analysis for tagged reactor assemblies  

Science.gov (United States)

The location of defective LMFBR fuel pins by the determination of gas tag isotopic ratios is discussed. The application of this method to the FFTF Reactor briefly described.

1979-03-01

236

Coastal Food Storage Locations- Kenai Fjords National Park  

Science.gov (United States)

This layer represents the different food storage facilities available at backcountry campsites along the coast of Kenai Fjords National Park. Site locations ... ...

237

Validation of flux mapping system (FMS) of TAPP-4 with TRIVENI  

International Nuclear Information System (INIS)

The reactor core of TAPP-3 and 4 is divided into 14 power zones for spatial power control. Corresponding to each zone is a light water zonal compartment. The 14 ZCCs are located in two radial planes, each containing 7 ZCCs. For each zone, power measurement is carried out using three cobalt Self Powered Neutron Detectors (SPNDs) at appropriate locations close to the respective ZCC. Since the zone power as obtained by the true average of the healthy zone control detector (ZCD) readings belonging to a particular zone may not correspond to its actual power because these 3 detectors per zone, measure only point fluxes but the zone extends over a large core region. Therefore accurate estimation of zone power calibration factors is required to estimate the zone powers and also to provide effective spatial power control to avoid the xenon induced spatial power oscillations in large PHWRs like 540 MWe Reactor. This accurate ...

2006-11-13

238

Sea-to-sky airshed ambient quality monitoring report : 1984-2001  

Energy Technology Data Exchange (ETDEWEB)

This report provides information to government and industry to enable decision-making and management of local environmental quality conditions. The need for a summary air quality report has arisen in recent years due to growing concerns about air quality. Increased growth in population and the tourism industry is placing additional pressures on environmental quality. The report summarized meteorological and air quality data collected by the British Columbia Ministry of Water, Land and Air Protection in the Sea-to-Sky airshed from 1984 to 2001. The airshed is located in the Lower Mainland region of British Columbia. Air quality monitoring was conducted for various periods at 18 different stations and meteorological monitoring was conducted at 4 locations. A list of both provincial and national air quality objectives and standards was provided, with definitions and reference levels from the Canadian Environmental Protection ...

2004-09-01

239

Natural vegetation at the proposed Reference Repository Location in southeastern Washington  

International Nuclear Information System (INIS)

The dominant shrubs were sagebrush and spiny hopsage; the herbs were dominated by cheatgrass and Sandberg bluegrass. Spiny hopsage appeared to be vulnerable to burning and also to damage by off-road vehicular traffic. It appears to have little or no ability to reproduce through seedlings; once the existing plants are killed they are not likely to be replaced, even if seed-producing plants are nearby. The only pure stand of spiny hopsage known to exist on the Hanford Site is on and near study plot 2H. Sagebrush, like spiny hopsage, is killed by burning and by heavy vehicles. Sagebrush is capable of reproducing via seeds, indicating that it is an inherently aggressive species with a capacity to reestablish itself if parent plants are in the vicinity to act as seed sources. Alien, annual plants, especially cheatgrass, were a major contributor to the herbaceous canopy cover in plots 3S, 4S, and 5S. However, native perennial grasses, especially Sandberg bluegrass, were a major contributor ...

240

Coal gasification via the Lurgi process: Topical report: Volume 1, Production of SNG (substitute material gas)  

Energy Technology Data Exchange (ETDEWEB)

A Lurgi baseline study was requested by the DOE/GRI Operating Committee of the Joint Coal Gasification Program for the purpose of updating the economics of earlier Lurgi coal gasification plant studies for the production of substitute natural gas (SNG) based on commercially advanced technologies. The current study incorporates the recent experience with large size Lurgi plants in an effort to improve capital and operating costs of earlier plant designs. The present coal gasification study is based on a mine mouth plant producing 250 billion Btu (HHV) per day of SNG using the Lurgi dry bottom coal gasification technology. A Western subbituminous coal was designated as the plant food, obtained from the Rosebud seam at Colstrip, Montana. This study presents the detailed description of an integrated facility which utilizes coal, air, and water to produce 250 billion Btu (HHV) per day of SNG. The plant consists of coal handling and preparation, twenty-six Lurgi dry ...

1984-09-01

241

Waste sampling and characterization facility (WSCF)  

Energy Technology Data Exchange (ETDEWEB)

The Waste Sampling and Characterization Facility (WSCF) complex consists of the main structure (WSCF) and four support structures located in the 600 Area of the Hanford site east of the 200 West area and south of the Hanford Meterology Station. WSCF is to be used for low level sample analysis, less than 2 mRem. The Laboratory features state-of-the-art analytical and low level radiological counting equipment for gaseous, soil, and liquid sample analysis. In particular, this facility is to be used to perform Resource Conservation and Recovery Act (RCRA) of 1976 and Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) of 1980 sample analysis in accordance with U.S. Environmental Protection Agency Protocols, room air and stack monitoring sample analysis, waste water treatment process support, and contractor laboratory quality assurance checks. The samples to be analyzed contain very low concentrations of radioisotopes. The ...

1994-10-01

242

Velocity measurement of wake behind flat plate simulating BWR fuel spacer  

International Nuclear Information System (INIS)

Velocity field behind a flat plate, placed near the wall in a narrow channel as a simulant of a BWR fuel spacer, was measured by using a hot wire anemometer. It was found that not only the positions where the dead water region behind flat plate disappeared but also the locations where the velocity relaxation completed were almost independent of the width of the clearance, although the local average velocity and velocity fluctuation immediately downstream the flat plate were affected by the difference in the clearance. The transverse flow diversions in the channel cross section were evaluated from the shape of the average velocity profile. The decrease of local flow rate near the channel wall, which may causes the drift flow behind a flat plate, was encouraged as the drag of clearance increased. Attempts have been made to measure spanwise velocity in the narrow channel. A spanwise velocity that occurred due to flow diversion was observed and its ...

2004-10-04

243

The Oak Ridge Y-12 Plant biological monitoring and abatement program for East Fork Poplar Creek  

Energy Technology Data Exchange (ETDEWEB)

In May 1985, a National Pollutant Discharge Elimination System permit was issued for the Oak Ridge Y-12 Plant, a nuclear weapons components production facility located in Oak Ridge, Tennessee, and operated by Martin Marietta Energy Systems, Inc., for the US Department of Energy. As a condition of the permit, a Biological Monitoring and Abatement Program (BMAP) was developed to demonstrate that the effluent limitations established for the Oak Ridge Y-12 Plant protect the classified uses of the receiving stream (East Fork Poplar Creek), in particular, the growth and propagation of fish and aquatic life, as designated by the Tennessee Department of Health and Environment. A second purpose for the BMAP is to document the ecological effects resulting from implementation of a water pollution control program that will include construction of nine new wastewater treatment facilities over the next 4 years. Because of the complex nature of the effluent ...

1989-10-01

244

Suitability of filter ash surfaces as locations for plants  

Energy Technology Data Exchange (ETDEWEB)

The possibility of a positive agricultural use of flue gas filter ash from brown coal power plants is investigated. The suggested measure is mixing ash dump surfaces with extremely acidic spoil bank soils, which balances the high pH value of the alkaline ash and contributes to improved nutrient and soil sorptive conditions. Optimum quantity of spoil bank sands in the mixture with ash is between 10% and 40%. The optimum quantity must be determined for each type of ash considering improvement of soil chemical conditions and water retention capacity. Filter ash properties vary widely; the required amount of spoil bank sand added to investigated ash surfaces near 3 brown coal power plants was between 25% and 30% of the mixture. The same favourable soil and ash mixture can be produced by adding 60% to 75% filter ash to acidic raw spoil bank soil surfaces forming a top soil layer in a thickness of minimum 60 cm. Tests of plant growth showed high crop yields in winter ...

1980-01-01

245

Suction effects in deep Boom clay block samples  

CERN Document Server

Extensive investigations have been and are being carried out on a stiff clay from an underground research laboratory located at Mol (Belgium) called Boom clay, in the context of research into deep nuclear waste disposal. Suction effects in deep Boom clay block samples were investigated through the characterisation of the water retention and of the swelling properties of the clay. The data obtained allowed an estimation of the sample initial suction that was reasonably compatible with the in-situ state of stress at a depth of 223 m. The relationship between suction and stress changes during loading and unloading sequences were also examined by running oedometer tests with suction measurements. A rather wide range of the ratio s/sigma 'v (being s the suction and sigma 'v the effective vertical stress) was obtained (0.61 - 1), different from that proposed by Bishop et al; (1974). Finally, the effect of suction release under an isotropic stress ...

2008-01-01

246

Serviceability of steam generators at NPPs with reactors of the WWER-440 and WWER-1000 types  

Energy Technology Data Exchange (ETDEWEB)

Steam generators (SG) are the weak link of nuclear power plants, their service life is shorter than the service life of other NPP components. This paper is dedicated to a statistical analysis of SG damages and failures. Heat exchanging tubes (HET) are the most damaged elements in SG, there are on average 286 plugged or repaired tubes in each operating SG. The usually mechanisms of tube failure are the following: denting, corrosion at tube outside, pitting, fretting, and circular crack propagation. Most of damages are located in the transition zone above a tube plate. This study shows that the factors that are involved in the SG HET fault probability are: - design features of SG and secondary equipment elements (high pressure feed heaters (HPFH), low pressure feed heater (LPFH)), - water chemistry at different points of condensate feed pipe, composition and density of deposits on HET surface, efficiency of mechanical and chemical washing, - the ...

2002-07-01

247

Review of Pacific Northwest Laboratory research on aquatic effects of hydroelectric generation and assessment of research needs  

Energy Technology Data Exchange (ETDEWEB)

This report is an overview of Pacific Northwest Laboratory's (PNL) research on how hydroelectric generation affects aquatic biota and environments. The major accomplishments of this research are described, and additional work needed to permit optimal use of available data is identified. The research goals are to: (1) identify impacts of hydroelectric generation, (2) provide guidance in allocating scarce water resources, and (3) develop techniques to avoid or reduce the impacts on aquatic communities or to compensate for unavoidable impacts. Through laboratory and field experiments, an understanding is being developed of the generic impacts of hydrogeneration. Because PNL is located near the Columbia River, which is extensively developed for hydroelectric generation, it is used as a natural laboratory for studying a large-scale operating system. Although the impacts studied result from a particular system of dams and operating ...

1981-05-01

248

Proteomic analysis of the shistosome tegument and its surface membranes  

Scientific Electronic Library Online (English)

Abstract in english The tegument surface of the adult schistosome, bounded by a normal plasma membrane overlain by a secreted membranocalyx, holds the key to understanding how schistosomes evade host immune responses. Recent advances in mass spectrometry (MS), and the sequencing of the Schistosoma mansoni transcriptome/genome, have facilitated schistosome proteomics. We detached the tegument from the worm body and enriched its surface membranes by differential extraction, before subjecting t (more) he preparation to liquid chromatography-based proteomics to identify its constituents. The most exposed proteins on live worms were labelled with impearmeant biotinylation reagents, and we also developed methods to isolate the membranocalyx for analysis. We identified transporters for sugars, amino acids, inorganic ions and water, which confirm the importance of the tegument plasma membrane in nutrient acquisition and solute balance. Enzymes, including phosphohydrolases, ...

2006-10-01

249

Potential for containment leak paths through electrical penetration assemblies under severe accident conditions  

International Nuclear Information System (INIS)

The leakage behavior of containments beyond design conditions and knowledge of failure modes is required for evaluation of mitigation strategies for severe accidents, risk studies, emergency preparedness planning, and siting. These studies are directed towards assessing the risk and consequences of severe accidents. An accident sequence analysis conducted on a Boiling Water Reactor (BWR), Mark I (MK I), indicated very high temperatures in the dry-well region, which is the location of the majority of electrical penetration assemblies. Because of the high temperatures, it was postulated in the ORNL study that the sealants would fail and all the electrical penetration assemblies would leak before structural failure would occur. Since other containments had similar electrical penetration assemblies, it was concluded that all containments would experience the same type of failure. The results of this study, however, show that this conclusion does ...

250

Nylon resin steadily infiltrating into the structural parts use field. Kiko buhin to shtie chakujitsuni shintosuru nairon jushi  

Energy Technology Data Exchange (ETDEWEB)

Considerations were given on typical applications of nylon resin parts to automotive use and their future trends through news topics. GF strengthened nylon resin is used in cylinder head covers substituting aluminum because of advantages in nylon resin of weight reducibility, vibration suppressibility, and noise shielding capability. Radiator tank uses N66GF 30% strengthened nylon in more than 60% of bonnet type passenger cars. Nylon resin is used most in harness connectors installed in locations that require heat resistance. External car parts such as bumpers, fenders, and wheel caps use to some extent nylon resin in the form of strengthened and up-graded polymer alloy. BMW in Germany used in its high-class production cars intake manifolds made of GF strengthened Nylon 66. The majority of engine{prime}s gas intake system parts has been replaced with Nylon blow-formed parts. The resin industry is aiming at developing Nylon resin with aromatic components to use into ...

1992-06-18

251

Localized deformation and IASCC initiation in austenitic stainless steels  

International Nuclear Information System (INIS)

Localized deformation may play a key role in the underlying mechanism of irradiation assisted stress corrosion cracking (IASCC) in light water reactor core components. In this study, four austenitic alloys, 18Cr8Ni, 15Cr12Ni, 13Cr15Ni and 21Cr32Ni, with different stacking fault energies were irradiated to 1 and 5 dpa at 360 deg. C using 3.2 MeV protons. Interrupted constant extension rate tensile (CERT) tests were conducted in a simulated BWR environment to determine IASCC susceptibility. In order to characterize the localized deformation in slip channels and grain boundaries, parallel CERT experiments were also performed in an argon atmosphere. Results show that the IASCC susceptibility of the tested alloys increases with increasing irradiation dose and decreasing stacking fault energy. IASCC tends to initiate at locations where slip channels intersect grain boundaries. Localized deformation in the form of grain boundary sliding due to the ...

2008-12-01

252

Groundwater surveillance plan for the Oak Ridge Reservation  

Energy Technology Data Exchange (ETDEWEB)

US Department of Energy (DOE) Order 5400.1 requires the preparation of environmental monitoring plans and implementation of environmental monitoring programs for all DOE facilities. The order identifies two distinct components of environmental monitoring, namely effluent monitoring and environmental surveillance. In general, effluent monitoring has the objectives of characterizing contaminants and demonstrating compliance with applicable standards and permit requirements, whereas environmental surveillance has the broader objective of monitoring the effects of DOE activities on on- and off-site environmental and natural resources. The purpose of this document is to support the Environmental Monitoring Plan for the Oak Ridge Reservation (ORR) by describing the groundwater component of the environmental surveillance program for the DOE facilities on the ORR. The distinctions between groundwater effluent monitoring and groundwater surveillance have been defined in the Martin Marietta ...

1994-07-01

253

Extension of the EQ3/6 computer codes to geochemical modeling of brines  

Energy Technology Data Exchange (ETDEWEB)

Recent modifications to the EQ3/6 geochemical modeling software package provide for the use of Pitzer's equations to calculate the activity coefficients of aqueous species and the activity of water. These changes extend the range of solute concentrations over which the codes can be used to dependably calculate equilibria in geochemical systems, and permit the inclusion of ion pairs, complexes, and undissociated acids and bases as explicit component species in the Pitzer model. Comparisons of calculations made by the EQ3NR and EQ6 compuer codes with experimental data confirm that the modifications not only allow the codes to accurately evaluate activity coefficients in concentrated solutions, but also permit prediction of solubility limits of evaporite minerals in brines at 25/sup 0/C and elevated temperatures. Calculations for a few salts can be made at temperatures up to approx. 300/sup 0/C, but the temperature range for most electrolytes is constrained ...

1984-10-23

254

Enhancing productivity of Indian basil (Ocimum basilicum L.) through harvest management under rainfed conditions of subtropical north Indian plains  

British Library Electronic Table of Contents (United Kingdom)

A field experiment was conducted during 2004 and 2005 at the research farm of Central Institute of Medicinal And Aromatic Plants, Lucknow located at 26.5^o N 80.5^o E and 120m above the mean sea level to study the effect of harvesting stage and cutting height on growth, yield and quality of Indian basil. The objective of this study was to increase the essential oil yield of Indian basil without adverse effect on quality by taking two harvests through manipulating harvesting stage and cutting height and to increase the land and rain water utilization efficiency under rain fed condition. The treatments consisted of four stages of first harvest (40, 60, 80 and 100 days after transplanting (DAT)) and three cutting height (0, 7.5 and 15.0cm above ground level). The Indian basil (Ocimum basilicu...

2010-01-01

255

Eielson Air Force Base OU-1 baseline risk assessment  

Energy Technology Data Exchange (ETDEWEB)

This Baseline Risk Assessment report is the second volume in a set of three volumes for operable Unit 1 (OU-1). The companion documents contain the Remedial Investigation and the Feasibility Study. Operable Unit 1 (OU-1) is one of several groups of hazardous waste sites located at Eielson Air Force Base (AFB) near Fairbanks, Alaska. The operable units at Eielson are typically characterized by petroleum, oil, lubricant/solvent contamination, and by the presence of organics floating at the water table. In 1989 and 1990, firms under contract to the Air Force conducted field studies to gather information about the extent of chemical contamination in soil, groundwater, and soil air pore space (soil gas) at the site. This report documents the results of a baseline risk assessment, which uses the 1989 and 1991 site characterization database to quantify the potential human health risk associated with past Base industrial activities in the vicinity of ...

1993-09-01

256

Effect of spatial variation on salinity tolerance of macroinvertebrates in Eastern Australia and implications for ecosystem protection trigger values  

International Nuclear Information System (INIS)

Salinisation of freshwater has been identified as a serious environmental issue in Australia and around the world. Protective concentrations (trigger values) for salinity can be used to manage salinity impacts, though require locally relevant salinity tolerance information. 72-h acute salinity tolerance values were determined for 102 macroinvertebrates collected from 11 locations in four biologically distinct freshwater bio-regions in Northeast Australia and compared with sensitivities observed in Southeast Australia. The salinity tolerance of individual taxa was consistent across Northeast Australia and between Northeast and Southeast Australia. However, two distinct communities were identified in Northeast Australia using distributions of the acute tolerance values and a calculated index of salinity sensitivity. Salinity trigger values should therefore be representative of local or regionally relevant communities and may be adequately calculated using sensitivity ...

2008-02-01

257

Ecology of microorganisms in desert soil environment. Sabaku dojo kankyo ni okeru biseibutsu seitai  

Energy Technology Data Exchange (ETDEWEB)

This paper indicates first that the base content in desert soil is by far much higher than that in soils in moist areas, that salts with the higher solubility to water have their deposition depth greater, and that the organic content is extremely low. The paper also describes the experiments to verify that the desert soil contains soil lumps with a diameter of about several millimeters, which function effectively to form the long term survival locations for microorganisms. Desert soil containing soil lumps and the one removed of lumps by pulverizing them into powder were prepared as test specimens, which were left submerged. It was confirmed that the velocity of decomposing the organics and the mechanical strength in the latter soil are obviously inferior to those in the former soil. Additional remarks are given that when the desert soil environment is changed the microorganisms get more active appreciably and that certain kinds of mold fungi ...

1991-11-01

258

Drought analysis of Nakdong River Basin based on multivariate stochastic models  

Energy Technology Data Exchange (ETDEWEB)

In this study, drought analysis of annual flows of Jindong, Hyunpoong, and Waekwan stations located at Nakdong River Basins was performed based on multivariate stochastic models. The stochastic models used were multivariate autoregressive model(MAR) and multivariate contemporaneous (MCAR) model. MCAR(1) and MAR(1) models were selected to be appropriate models for these stations based on skewness test of normality, test of uncorrelated residuals, and correlograms of the residual series of each model. The statistics generated by MCAR(1) model and MAR(1) model resembled very closely those computed from historical series. The drought characteristics such as run length, run sum, and run intensity were fairly well reproduced for the various lengths of generated annual flows based on the MCAR(1) and MAR(1) models. Thus, these drought characteristics may give the important information in planning mid or long term water supplying systems. (author). 18 ...

1997-04-30

259

Development and manufacture of tritium-in-air monitors for Indian PHWRs  

International Nuclear Information System (INIS)

Tritium, a beta emitting gas at room temperature causes a biological hazard in the locations where it is present beyond acceptable limits. The hazard can be due to inhalation, and absorption by skin. Hence is the necessity of Tritium monitoring instruments/systems for ensuring safety in the PHWRs and the nuclear research plants and laboratories. It is desirable that the instruments address satisfactorily to certain factors like the following: (i) Wide range of Tritium concentrations - 1 to 104 DAC ( Derived Air Concentration) (ii) On-line monitoring features (iii) Small response time (On-spot instantaneous measurements) (iv) Portability (v) Mitigation of memory effects. This paper presents an overview of the Online Tritium in Air Monitoring Systems manufactured by ECIL for Pressurised Heavy Water Reactors at Tarapur, Kaiga, and Rawatbhata. Significant aspects of design, function, testing, limitations of the detectors and electronics and the ...

2009-10-01

260

Design of the electromagnetic fluctuations diagnostic for MFTF-B  

Energy Technology Data Exchange (ETDEWEB)

The Electromagnetic Fluctuations (EMF) diagnostic will be used to monitor ion fluctuations which could be unstable in MFTF-B. Each probe assembly includes a high impedance electrostatic probe to measure potential fluctuations, and a group of nested, single turn loops to measure magnetic fluctuations in three directions. Eventually, more probes and loops will be added to each probe assembly for making more detailed measurements. The sensors must lie physically close to the plasma edge and are radially positionable. Also, probes at separate axial locations can be positioned to connect along the same magnetic field line. These probes are similar in concept to the rf probes used on TMX, but the high thermal load for 30-second shots on MFTF-B requires a water-cooled design along with temperature monitors. Each signal channel has a bandwidth of .001 to 150 MHz and is monitored by up to four different data channels which obtain amplitude and frequency ...

1983-11-28

261

Design modifications in 540 MWe and its impact on the dose rates  

International Nuclear Information System (INIS)

Exposure control at the operating Nuclear Power Station is a major concern. TAPS Unit-4 is the first Pressurized Heavy Water Reactor of 540 MWe electrical capacity. This unit was made critical on March 6, 2005. In-depth review of radiation safety was done to identify the impact of design modification on dose rates at various locations and on the equipment's. Problems encountered in controlling the dose rates in 220 MWe electrical are eliminated by appropriate design modifications. Due to higher capacity of the unit there are design changes in major systems such as reactor core, primer heat transport system, moderator system, reactor regulation and protection systems. Reactor operations and maintenance activities during shut down contributes to exposure of the employees. Based on the experience gained in the operation of 220 MWe, design modifications incorporated in TAPS unit-4 and dose rate measurements carried out at 90 % full power, through ...

2005-11-23

262

Conjugate heat transfer of a finned tube. Part B: Heat transfer augmentation and avoidance of heat transfer reversal by longitudinal vortex generators  

Energy Technology Data Exchange (ETDEWEB)

Numerical investigations of three-dimensional flow and heat transfer in a finned tube with punched longitudinal vortex generators (LVG`s) are carried out for Reynolds number of 250 and 300. Air with a Prandtl number of 0.7 is used as the fluid. The flow is both thermally and hydrodynamically developing. The LVG is a delta winglet pair (DWP) punched out of the fin and is located directly behind the tube, symmetrically separated by one tube diameter. The DWP generates longitudinal vortices in the wake of the tube, defers flow separation on the tube, deflects the main stream into the tube wake, and strong reduces the ``dead water zone.`` Heat transfer reversal is avoided by the DWP. Comparison of the span-averaged Nusselt numbers for the fin with and without DWP shows significant local heat transfer enhancement of several hundred percent in the tube wake. For Re = 300 and Fi = 200 the global heat transfer augmentation by a DWP, which amounts to ...

1995-08-01

263

Chalk Point cooling tower project native vegetation study. Final report 1979  

Science.gov (United States)

The Potomac Electric Power Company generating station at Chalk Point, MD, utilizes brackish water in its natural draft cooling tower and, consequently, releases saline aerosol into the atmosphere. A research and monitoring project was established in 1974 to evaluate the effects of this drift on native perennial vegetation. Leaf samples have been collected form dogwood, Cornys florida, Virginia pine, Pinus virginiana, black locust, Robinia pseudoacacia, and sassafras, Sassafras albidum, located at 12 different sites in the vicinity of the power plant. Sampling was begun prior to the operation of the cooling tower, 1974, and continued through 1978. Complete results from monthly monitoring of foliar chloride in the four native tree species is documented for May through September 1978. Results from salt spray experiments indicate chloride and sodium concentrations in the wood of dogwood trees increases with increased spraying levels.

1979-06-01

264

Break Nodalization Influence to IAEA-SPE-4 Test Simulation  

International Nuclear Information System (INIS)

A small break LOCA event simulation with no high pressure injection system available, known as International Atomic Energy Agency Standard Problem Exercise no. 4 (IAEA-SPE-4), was performed on the PMK-2 integral test facility in Budapest in 1993. This paper analyses the response of the PMK-2 facility, a model of VVER-440 nuclear power plant, using the latest released version MOD3.2.1.2 of the RELAP5 thermal-hydraulic code. After several years of the SPE-4 experiment analyses, many problems have emerged and been studied. Main goal of the present analyses was to study the main influencing parameters for adequate modelling of the hexagonal core channel with 19-rod bundle and phenomena during the core uncovery. Some influencing parameters have been identified, mostly on the primary side, but some also on the secondary side. This is exact simulation of main coolant pump coast down, hydro-accumulators water temperature and connections to the primary system. Some concern ...

1998-06-15

265

Assessment of oil shale technologies  

Energy Technology Data Exchange (ETDEWEB)

For many decades, the oil shale resources of the western United States have been considered possible contributors to the Nation's liquid fuel supply. This volume reviews several paths to development of these resources and the likely consequences of following these paths. A chapter providing background information about the nature of oil shale is followed by an evaluation of technologies for recovery of shale oil. The economics and finances of establishing an industry of various sizes are analyzed. The fact that much of the best shale is located on Federal land is examined in light of the desire to increase use of the resources. The consequences of shale development in terms of impact on the physical and social environments, and a discussion of the availability of water complete the report. Policy options addressing barriers that could hinder the establishment of the industry are presented. These options, designed primarily for ...

1980-06-01

266

Apollo II - Thermal use of chicken droppings - Phase II; Apollo II - Thermische Nutzung von Huehnermist, Phase II  

Energy Technology Data Exchange (ETDEWEB)

This report made for the Swiss Federal Office of Energy (SFOE) discusses the conception, planning and construction of an easy-to-operate pilot heating plant that uses chicken litter as its fuel. The plant, which is installed at a chicken farm in Boesingen, Switzerland, produces 250 - 350 kW and not only supplies heat for two chicken sheds and two households, but also provides energy for a drying plant in summer. The results of measurements made on emissions are discussed and, within the framework of an eco-balance analysis, comparisons are made between the direct use of the droppings as manure or as a fuel. The cost-effectiveness of the plant is examined and the influence of plant size and other factors discussed. Further, legal questions concerning the use of chicken litter as a fuel for heating installations are discussed; the use of the droppings as a fuel is not foreseen in the legislation concerning water protection and airborne emissions of pollutants. ...

2001-07-01

267

An assessment of metal contamination along the Irish coast using the seaweed Ascophyllum nodosum (Fucales, Phaeophyceae)  

Energy Technology Data Exchange (ETDEWEB)

The relative abundance and variation of Cr, Co, Cd and Pb in Ascophyllum nodosum and intertidal surface sediments from six locations around the coast were assessed over six seasons. Higher Cd and Pb levels in Galway Docks and Cork Harbour were attributed to localised inputs of these metals from municipal and domestic waste, while at a reference site (Ballyconneely), high algal Cr concentrations were considered a function of geological setting rather than anthropogenic loading. Little seasonal variation was observed, with the exception of higher Co levels in plants in winter, associated with growth dynamics and increased fluvial inputs. In comparison with previously published data for metals in A. nodosum from the North Atlantic, with the exception of localised hot spots, the Irish coastline is still a relatively pristine environment. A. nodosum may be successfully and easily used as a biomonitor of metal contamination in coastal waters. - This ...

2008-03-15

268

A Precision Measurement of the Neutrino Mixing Angle theta_13 using Reactor Antineutrinos at Daya Bay  

CERN Document Server

A reactor-neutrino experiment, Daya Bay, has been proposed to determine the least-known neutrino mixing angle theta_13 using electron antineutrinos produced at the Daya Bay nuclear power complex in China. Daya Bay is an international collaboration with institutions from China, the United States, the Czech Republic, Hong Kong, Russia, and Taiwan. The experiment will use eight identical detectors deployed at three different locations optimized for monitoring the antineutrino rates from the six reactors and for detecting any rate deficit and spectral distortion near the first oscillation maximum. The overburden of the under ground experimental halls, connected with tunnels, ranges from about 250 to 900 meters-water-equivalent so that the cosmogenic background is small compared to the number of observed antineutrino events. Civil construction of tunnels and experimental facilities is planned to start in 2007, with detector construction beginning in ...

2007-01-01

269

55 Cancri: Stellar Astrophysical Parameters, a Planet in the Habitable Zone, and Implications for the Radius of a Transiting Super-Earth  

CERN Document Server

The bright star 55 Cancri is known to host five planets, including a transiting super-Earth. The interferometric study presented here yields directly determined values for 55 Cnc's stellar astrophyiscal parameters: $R=0.943 \\pm 0.010 R_{\\odot}$, $T_{\\rm EFF} = 5196 \\pm 24$ K. We use isochrone fitting to determine 55 Cnc's age to be 10.2 $\\pm$ 2.5 Gyr, implying a stellar mass of $0.905 \\pm 0.015 M_{\\odot}$. Our analysis of the location and extent of the system's habitable zone (0.67--1.32 AU) shows that planet f ($M \\sin i = 0.155 M_{Jupiter}$) spends the majority of the duration of its elliptical orbit in the circumstellar habitable zone, where, with moderate greenhouse heating, it could harbor liquid water. Finally, our direct value for 55 Cancri's stellar radius allows for a model-independent calculation of the physical diameter of the transiting super-Earth 55 Cnc e ($\\sim 2.05 \\pm 0.15 R_{\\earth}$), which, depending on the ...

2011-01-01

270

3-dimensional observations of atmospheric variables during the field campaign COPS  

Energy Technology Data Exchange (ETDEWEB)

The Convective and Orographically-induced Precipitation Study (COPS) has the aim to advance the quality of forecasts of orographically-induced precipitation in complex terrain. COPS is a Research and Development Project of the World Weather Research Program and considered to be one of the largest field campaigns on quantitative precipitation forecasting that has been performed so far. A network of state-of-the-art active and passive remote sensing systems was combined with in total 10 airborne platforms, Meteosat rapid scans and dense networks of standard meteorological instruments during the three months long field phase (June-August, 2007) in south-western Germany/eastern France to observe atmospheric variables in the three spatial dimensions and in time. By the University of Hohenheim, two novel ground-based mobile scanning lidar systems were deployed: a scanning rotational Raman lidar which provides combined measurements of the field of atmospheric temperature and aerosol optical ...

2008-05-01

272

Special hardware processor to be used in intersection region I-6 of the ISR  

CERN Multimedia

It was in the intersection I-6 that the experiment R603 was located

1974-01-01

275

Water Quality Criteria | Water Quality Criteria | US EPA  

Science.gov (United States)

for? Learn the Issues Science & Technology Laws & Regulations About EPA Contact Us Water: Water Quality Criteria You are here: Water Science & Technology Surface Water Standards &...

2011-08-28

276

Investigation of contaminant sources at Navarre, Kansas.  

Energy Technology Data Exchange (ETDEWEB)

The results of the 2006 investigation of contaminant sources at Navarre, Kansas, clearly demonstrate the following: {sm_bullet} Sources of carbon tetrachloride contamination were found on the Navarre Co-op property. These sources are the locations of the highest concentrations of carbon tetrachloride found in soil and groundwater at Navarre. The ongoing groundwater contamination at Navarre originates from these sources. {sm_bullet} The sources on the Co-op property are in locations where the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) never conducted grain storage operations. {sm_bullet} No definitive sources of carbon tetrachloride were identified on the portion of the current Co-op property formerly used by the CCC/USDA. {sm_bullet} The source areas on the Co-op property are consistent with the locations of the most intense Co-op operations, both historically and at present. The Co-op ...

2007-11-05

277

MENDING THE IN SITU MANIPULATION BARRIER  

Energy Technology Data Exchange (ETDEWEB)

In early 2004, the U.S. Department of Energy (DOE) Richland and Fluor Hanford requested technical assistance from the DOE Headquarters EM-23 Technical Assistance Program to provide a team of technical experts to develop recommendations for mending the In Situ Redox Manipulation (ISRM) Barrier in the 100-D Area of the Hanford Site in Washington State. To accommodate this request, EM-23 provided support to convene a group of technical experts from industry, a national laboratory, and a DOE site to participate in a 2 1/2-day workshop with the objective of identifying and recommending options to enhance the performance of the 100-D Area reactive barrier and of a planned extension to the northeast. This report provides written documentation of the team's findings and recommendations. In 1995, a plume of dissolved hexavalent chromium [Cr(VI)], which resulted from operation of the D/DR Reactors at the Hanford site, was discovered along the Columbia River shoreline and in the 100-D ...

2006-02-06

278

Sensitivity analysis and development of calibration methodology for near-surface hydrogeology model of Laxemar  

Energy Technology Data Exchange (ETDEWEB)

This report describes modelling where the hydrological modelling system MIKE SHE has been used to describe surface hydrology, near-surface hydrogeology, advective transport mechanisms, and the contact between groundwater and surface water within the SKB site investigation area at Laxemar. In the MIKE SHE system, surface water flow is described with the one-dimensional modelling tool MIKE 11, which is fully and dynamically integrated with the groundwater flow module in MIKE SHE. In early 2008, a supplementary data set will be available and a process of updating, rebuilding and calibrating the MIKE SHE model based on this data set will start. Before the calibration on the new data begins, it is important to gather as much knowledge as possible on calibration methods, and to identify critical calibration parameters and areas within the model that require special attention. In this project, the MIKE SHE model has been further developed. The model ...

2007-11-15

281

STOMP Subsurface Transport Over Multiple Phases Version 1.0 Addendum: ECKEChem Equilibrium-Conservation-Kinetic Equation Chemistry and Reactive Transport  

Energy Technology Data Exchange (ETDEWEB)

Geologic sequestration is currently being practiced and scientifically evaluated as a critical component in a broad strategy, comprising new practices and technologies, for mitigating global climate change due to anthropogenic emissions of CO2. Demonstrating that geologic sequestration of CO2 is safe and effective, and gaining public acceptance of sequestration technologies are critically important in meeting these global climate change challenges. Monitored field-scale demonstrations of geologic sequestration of carbon dioxide will contribute greatly toward growing trust and confidence in the technology; however, pilot demonstrations ultimately will not be the norm for new geological sequestration deployments. Instead, scientists, engineers, regulators, and ultimately the public will rely on numerical simulations to predict the performance of geologic repositories for carbon dioxide sequestration. The U.S. Department of Energy (DOE), through the National Environmental Technology ...

2005-12-01

282

Quantitative measurements of injections into porous media with contrast based MRI  

British Library Electronic Table of Contents (United Kingdom)

Porous flow occurs in a wide range of materials and applies to many commercially relevant applications such as oil recovery, chemical reactors and contaminant transport in soils. Typically, breakthrough and pressure curves of column floods are used in the laboratory characterization of these materials. These characterization methods lack the detail to easily and unambiguously resolve flow mechanisms with similar effects at the core scale that can dominate at the aquifer or oil field scale, as well as the effects of geometry that control the flow at interfaces as in a perforated well or the inlet of an improperly designed column. Non-invasive imaging techniques such as MRI have been shown to provide a far more detailed characterization of the properties of the solid matrix and flow, but usu...

2011-01-01

283

Late cenozoic evolution of Fortymile Wash: Major change in drainage pattern in the Yucca Mountain, Nevada region during late miocene volcanism  

International Nuclear Information System (INIS)

The site characterization of Yucca Mountain, NV as a potential high level nuclear waste repository includes study of the surficial deposits as a record of the paleoenvironmental history of the Yucca Mountain region. An important aspect of this history is an understanding of the evolution of paleogeography leading to establishment of the present drainage pattern. Establishment of drainage basin evolution is needed before geomorphic response to paleoclimate and tectonics can be assessed, because a major change in drainage basin geometry can predominantly affect the sedimentary record. Because alluvial aquifers are significant to regional hydrology, a major change in surface drainage resulting in buried alluvium could have hydrogeologic significance. In this paper, we report on geologic evidence for a major modification in surface drainage pattern in the Yucca Mountain region, resulting in the probable establishment of the Fortymile Wash drainage basin by latest ...

1994-05-22

284

Evaluation of the concept SPEOS applied to the exploitation of industrial waste heat stored in an underground seasonal storage; Prospection et evaluation du potentiel d`application du concept SPEOS a la valorisation des rejets thermiques industriels par stockage saisonnier souterrain  

Energy Technology Data Exchange (ETDEWEB)

SPEOS takes advantage of a geological situation which apparently does not occur much in Switzerland. The SPEOS pilot installation, which was erected in 1982, is designed for the supply of heat for about 500 persons. In the course of 10 cycles, the possibilities and limits of the seasonal heat storage were displayed. It was demonstrated that large quantities of heat with temperatures of up to 75 C can be stored in an aquifer. The behaviour of such a storage can be predicted with sufficient accuracy with mathematical models. (author) 12 refs.

1993-09-01

285

Energy R and D. Geothermal energy and underground reservoirs; R et D energie. Geothermie et reservoirs souterrains  

Energy Technology Data Exchange (ETDEWEB)

Geothermal energy appears as a viable economic alternative among the different renewable energy sources. The French bureau of geological and mining researches (BRGM) is involved in several research and development programs in the domain of geothermal energy and underground reservoirs. This document presents the content of 5 programs: the deep hot dry rock system of Soultz-sous-Forets (construction and testing of the scientific pilot, modeling of the reservoir structure), the development of low and high enthalpy geothermal energy in the French West Indies, the comparison of the geothermal development success of Bouillante (Guadeloupe, French West Indies) with the check of the geothermal development of Nyssiros (Greece) and Pantelleria (Italy), the development of the high enthalpy geothermal potentialities of Reunion Island, and the underground storage of CO{sub 2} emissions in geologic formations (deep aquifers, geothermal reservoirs, abandoned mines or oil ...

2001-07-01

286

Theory and method for selection of power system stabilizer location  

Energy Technology Data Exchange (ETDEWEB)

A new approach for the selection of best PSS locations in multimachine power systems is proposed in this paper. Study shows that the right-eigenvector measures the activity of state variables and the left-eigenvector measures the control effect of control signals. Based on the right and left eigenvector the concept of sensitivity of PSS effect (SPE) is presented and used to identify the best PSS locations. The proposed method is used to identify the best PSS location in a 13-machine system to increase the damping of an interarea mode. The time-domain simulation results confirm that the prediction of best PSS location by SPE method is correct and accurate.

1991-03-01

287

Forum: Science and Innovation for Sustainable Development - Opportunities  

Wastenet

...assistantship in Suburban Ecology Location: Bedford, NY Deadline: August 15, 2008 Postdoctoral Fellow in energy Location: University of Waterloo, Ontario, Canada Deadline: August 11, 2008 Junior Professional Fellowship Sustainable Development Governance Programme Location: UNU, Yokohama, Japan Deadline: August 1, 2008 Center for Ocean Solutions Early Career Fellowship Program Location: Stanford, California Deadline: July 15, 2008 Asian MetaCentre for Population and Sustainable Development Analysis Postdoctoral Research Fellow Location: Singapore Deadline: July 15, ...

288

Breached fuel location in FFTF by delayed neutron monitor triangulation  

International Nuclear Information System (INIS)

The purpose of this work was to develop and evaluate a method of locating breached fuel within the Fast Flux Test Facility (FFTF) reactor based on the relative response of the delayed neutron monitors (DNM) located on each of the three primary sodium cooling loops. The primary method of location is the use of tag gas containing unique ratios of the noble gases xenon and krypton. Although the tag gas system works quite well, it is relatively expensive because of the costs of preparing and loading the gas into each fuel pin. Triangulation of DNM signals could potentially decrease tag gas costs while maintaining overall location reliability.

1985-11-10

289

Photocatalytic oxidation and reduction chemistry and a new process for treatment of pink water and related contaminated water  

Energy Technology Data Exchange (ETDEWEB)

The objective of this project was to develop new photocatalytic or other innovative process chemistry for the treatment of pink water and related contaminated water.

1996-10-01

290

The possibility for formation of macro-cell corrosion in a liquid with low electrical conductivity  

International Nuclear Information System (INIS)

The possibility of electrochemical corrosion of carbon steel at the rate of 3.25 x 10"-"5 A/cm"2 in water was examined under the conditions present during an accidental pipe rupture at the Mihama nuclear power plant: liquid conductivity, 7.5 #mu#S/cm; dissolved oxygen concentration, 5 ppb or less; pH 8.6#propor to#9.3; ferrous ion concentration, 20 ppb or less; temperature, 142 C. The corrosion rate of iron in a micro-cell with a dissolved oxygen reduction cathode was estimated to be only 1/400 of the preceding rate. On the other hand, that in a micro-cell with a hydrogen ion reduction cathode was estimated to be as high as 1/10 of the preceding rate, that is, 3.25 x 10"-"6 A/cm"2. Two important factors may have influenced the corrosion rate: the remarkable wall thinning, which must have been the direct cause of the rupture of the pipe, was located close to, and downstream from, an orifice; and, the water temperature was in ...

2011-05-01

291

Terra Nova tow-out poised as next East Coast event  

Energy Technology Data Exchange (ETDEWEB)

This spring, Newfoundland will send off a floating production, storage and offloading (FPSO) vessel to the offshore Terra Nova field. The Terra Nova will proceed southeast through Bull Arm, then northeast out of Trinity Bay, then heads southeast to the Jeanne d'Arc Basin on the Grand Banks. The Terra Nova is expected to produce 115,000 barrels of oil per day for six years, when it reaches full capacity. The consortium, headed by Petro-Canada as senior ownership partner and operator, built an environment protection program into every aspect of the project. Some of the features of the environment protection program include glory holes excavated on the ocean floor for the protection of production equipment from icebergs, to a flare stack on the platform, which has four legs to provide stability in rough seas. The FPSO was designed to withstand sea ice, icebergs, and severe winter storms. Flow lines are also protected, and in the event that a line is damaged, sea ...

2001-01-15

292

Remedial investigation/feasibility study report for lower Watts Bar Reservoir Operable Unit  

Energy Technology Data Exchange (ETDEWEB)

This document is the combined Remedial Investigation and Feasibility Study Report for the Lower Watts Bar Reservoir (LWBR) Operable Unit (OU). The LWBR is located in Roane, Rhea, and Meigs counties, Tennessee, and consists of Watts Bar Reservoir downstream of the Clinch River. This area has received hazardous substances released over a period of 50 years from the U.S. Department of Energy`s Oak Ridge Reservation (ORR), a National Priority List site established under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). As required by this law, the ORR and all off-site areas that have received containments, including LWBR, must be investigated to determine the risk to human health and the environment resulting from these releases, the need for any remedial action to reduce these risks, and the remedial actions that are most feasible for implementation in this OU. Contaminants from the ORR are primarily transported to the LWBR via the ...

1994-08-01

293

Northeast U.S. LNG project expansions : are they competing or complementary projects?  

Energy Technology Data Exchange (ETDEWEB)

The Northeast Gateway Energy Bridge Deepwater Port project was commissioned in 2005 and is based on a proprietary energy bridge shipboard regasification technology. The offshore liquefied natural gas (LNG) facility will be located in federal waters 13 miles southeast of Gloucester and was designed to cope with the extreme weather of the Massachusetts Bay. A dual-buoy system will be capable of ensuring continuous delivery of natural gas. Throughput capacity will range from 400 to over 800 MMcf/d. Vessels used at the port have capacities of 138,000 m{sup 3} and 150,900 m{sup 3} with peak sendout rates of 600 MMcf/d. The vessels have the capacity to rapidly increase and decrease their delivery rates. During periods of peak demand, 2 vessels can be simultaneously accommodated at the port, which has been designed to accommodate larger vessels to maximize future throughput. This presentation presented details of the port's design phases and ...

2006-07-01

294

Hydrogeology and tritium transport in Chicken Creek Canyon,Lawrence Berkeley National Laboratory, Berkeley, California  

Energy Technology Data Exchange (ETDEWEB)

This study of the hydrogeology of Chicken Creek Canyon wasconducted by the Environmental Restoration Program (ERP) at LawrenceBerkeley National Laboratory (LBNL). This canyon extends downhill fromBuilding 31 at LBNL to Centennial Road below. The leading edge of agroundwater tritium plume at LBNL is located at the top of the canyon.Tritium activities measured in this portion of the plume during thisstudy were approximately 3,000 picocuries/liter (pCi/L), which issignificantly less than the maximum contaminant level (MCL) for drinkingwaterof 20,000 pCi/L established by the Environmental ProtectionAgency.There are three main pathways for tritium migration beyond theLaboratory s boundary: air, surface water and groundwater flow. Thepurpose of this report is to evaluate the groundwater pathway.Hydrogeologic investigation commenced with review of historicalgeotechnical reports including 35 bore logs and 27 test pit/trench logsas well as existing ERP ...

2007-10-31

295

Fiscal 2000 project of inviting proposals for international joint research - invitation for international proposal (Energy conservation No.2). Achievement report on international joint study on popularization promotion of geothermal heat pump-assisted environmentally compatible heating system for Changchun City, China; 2000 nendo kokusai kyodo kenkyu teian kobo jigyo - kokusai teian kobo (Shoe No.2). Chinetsu heat pump ni yoru Chugoku Changchun shi kankyo tekigogata danbo system no fukyu sokushin ni kansuru kokusai kyodo kenkyu seika hokokusho  

Energy Technology Data Exchange (ETDEWEB)

A geothermal heat pump-assisted heating system is introduced into Changchun City and a survey is conducted to determine if the system may be popularized in this extremely cold region located in the northeastern part of China. In concrete terms, the hot water that circulates through the office building of Changchun Ground Heat Development Co., Ltd., is switched to hot water prepared by a geothermal heat pump. The test continued from December 2000 to March 2001. It is then concluded that heating by geothermal heat pumps will be fully serviceable to Changchun City. Implemented are (1) the shift from the coal fired boiler system to a geothermal heat pump system comprising 16 subterranean heat exchangers for the heating of the office building which is approximately 1000 m{sup 2} large, (2) long-term monitoring of the operating conditions, (3) measurement of subterranean heat exchanger thermal conductivity and subterranean ...

2001-03-01

296

Cooling of nuclear power stations with high temperature reactors and helium turbine cycles  

International Nuclear Information System (INIS)

On nuclear power stations with high temperature reactors and helium turbine cycles (HTR-single circuits) the residual heat from the energy conversion process in the primary and intermediate coolers is removed from cycled gas, helium. Water, which is circulated for safety reasons through a closed circuit, is used for cooling. The primary and intermediate coolers as well as other cooling equipment of the power plant are installed within the reactor building. The heat from the helium turbine cycle is removed to the environment most effectively by natural draught cooling towers. In this way a net plant efficiency of about 40% is attainable. The low quantities of residual heat thereby produced and the high (in comparison with power stations with steam turbine cycles) cooling agent pressure and cooling water reheat pressure in the circulating coolers enable an economically favourable design of the overall 'cold end' to be expected. In the so-called ...

297

Climate change, agriculture and wetlands in Eastern Europe: vulnerability, adaptation and policy  

Energy Technology Data Exchange (ETDEWEB)

Naturally-occurring wetlands perform such functions as flood control, pollution filtration, nutrient recycling, sediment accretion, groundwater recharge and water supply, erosion control, and plant and wildlife preservation. A large concentration of wetlands is located in Eastern Europe. A significant amount of Eastern European wetlands has been converted to agricultural use in the past, and remaining wetlands are subject to agricultural drainage. Drained wetlands are used as prime agriculture lands for a variety of food crops. Other agricultural uses of wetlands range from growing Phragmites australis (common reed) for thatch and livestock feed, to collecting peat for heating and cooking fuel. Altered hydrologic regimes due to global climate change could further exacerbate encroachment of agricultural land use into wetlands. The vulnerability and adaptation studies of the US Country Studies Program are used to analyze where climate change ...

1997-05-01

298

Assessment Of Heavy Metal Contamination Of Arable Soils In Central Bekaa Plain, Lebanon  

International Nuclear Information System (INIS)

The study area is located in the Bekaa plain of Lebanon totaling about 12753 ha. It lies between the eastern foothills of Mount Lebanon chain and expands across the Litani River towards the foothills of the eastern Anti-Lebanon Mountains. Its characteristics, i.e. natural terrain, climate and socio-economy, make it vulnerable especially due to soil pollution. This paper tries to identify the nature and level of soil pollution by heavy metals. Valley slopes represent a complex landform and lithology that contributed to the formation of different soil. Agriculture in the plain is being practiced mainly with cash, field crops and vegetables. Throughout the central part of the plain, groundwater table is abundant and relatively high (<1.0 m. locally) that multiplies the vulnerability of the soil-groundwater system. There are different sources of pollution, such as industrial (tanneries, batteries, leather manufacturing), solid and liquid wastes, and agricultural due ...

2004-12-04

299

A cryocondensation pump for the DIII-D Advanced Divertor Program  

Energy Technology Data Exchange (ETDEWEB)

A cryocondensation pump was designed for the baffle chamber of General Atomics DIII-D tokamak and will be installed in the fall of 1992. The purpose of the pump is to study plasma density control by pumping the divertor. The pump is toroidally continuous, approximately 10 m long and located in the lower outer corner of the vacuum chamber of the machine. It consists of a 1 m{sup 2} liquid helium-cooled surface surrounded by a liquid nitrogen-cooled shield to limit the heat load on the helium-cooled surface. The liquid nitrogen-cooled surface is surrounded by a radiation/particle shield to prevent energetic particles from impacting and releasing condensed water molecules. A thermal enhancement coating was applied to the nitrogen shell to lower the maximum temperature of the shell. The coating is non-continuous to keep the toroidal electrical resistance high. The whole pump is supported off the water-cooled vacuum vessel wall. ...

1992-03-01

300

Water resources data for Oklahoma, water year 1992. Volume 2. Red River Basin. Water-data report (Annual), 1 October 1991-30 September 1992  

Energy Technology Data Exchange (ETDEWEB)

Volume 2 of the water resources data for the 1992 water year for Oklahoma consists of record of stage, discharge, and water quality of streams; stage, contents, and water quality of lakes or reservoirs; and water levels of ground-water well. The report contains discharge records for 136 gaging stations; stage and contents for 31 lakes or reservoirs; water quality for 50 gaging stations. Also included are 61 partial-record or miscellaneous streamflow stations and 28 ground-water sites.

1993-04-01

301

From tankers to tissues : tracking the degradation and fate of oil discharges in Port Valdez, Alaska  

Energy Technology Data Exchange (ETDEWEB)

An average of 9 million gallons per day of oil-contaminated ballast water off loaded from tankers are treated at the Alyeska Pipeline Service Company Ballast Water Treatment Facility at the terminus of the Trans-Alaska Pipeline in Port Valdez, Alaska. This paper focuses on the results of 2 Prince William Sound Regional Citizens' Advisory Council monitoring programs which detail changes in the chemical composition of treated ballast water as it moves from tankers through the facility and subsequently traces the effluent hydrocarbons into the receiving environment of Port Valdez. The treatment facility involves gravity separation tanks, dissolved air flotation cells and biological treatment tanks. Effluent containing traces of volatile aromatics, including benzene, toluene, ethylbenzene and xylenes, low levels of oil, saturated hydrocarbons and polycyclic aromatic hydrocarbons is being continuously discharged to Port ...

2005-07-01

302

Data Center Energy Benchmarking: Part 3 - Case Study on an ITEquipment-testing Center (No. 20)  

Energy Technology Data Exchange (ETDEWEB)

The data center in this study had a total floor area of 3,024 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 147 racks, and was located in a 96,000 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but was served by the main building chiller plant and make-up air system. Additionally it was served by only a single electrical supply with no provision for backup power in the event of a power outage. The Data Center operated on a 24 hour per day, year-round cycle, and users had full-hour access to the data center facility. The study found that data center computer load accounted for 15% of the overall building electrical load, while the total power consumption attributable to the data center including allocated cooling load and lighting was ...

2007-07-01

303

DISTRIBUTION AND RANGE OF RADIONUCLIDE SORPTION COEFFICIENTS IN A SAVANNAH RIVER SITE SUBSURFACE: STOCHASTIC MODELING CONSIDERATIONS  

Energy Technology Data Exchange (ETDEWEB)

The uncertainty associated with the sorption coefficient, or K{sub d} value, is one of the key uncertainties in estimating risk associated with burying low-level nuclear waste in the subsurface. The objective of this study was to measure >648 K{sub d} values and provide a measure of the range and distribution (normal or log-normal) of radionuclide K{sub d} values appropriate for the E-Area disposal site, within the Savannah River Site, near Aiken South Carolina. The 95% confidence level for the mean K{sub d} was twice the mean in the Aquifer Zone (18-30.5 m depth), equal to the mean for the Upper Vadose Zone (3.3-10 m depth), and half the mean for the Lower Vadose Zone (3.10-18 m depth). The distribution of K{sub d} values was log normal in the Upper Vadose Zone and Aquifer Zone, and normal in the Lower Vadose Zone. To our knowledge, this is the first report of natural radionuclide Kd variability in the literature. Using ranges and ...

2010-01-11

304

Numerical modelling of surface hydrology and near-surface hydrogeology at Forsmark. Site descriptive modelling SDM. Site Forsmark  

Energy Technology Data Exchange (ETDEWEB)

SKB is currently performing site investigations at two potential sites for a final repository for spent nuclear fuel. This report presents results of water flow and solute transport modelling of the Forsmark site. The modelling reported in this document focused on the near-surface groundwater, i.e. groundwater in Quaternary deposits and shallow rock, and surface water systems, and was performed using the MIKE SHE tool. The most recent site data used in the modelling were delivered in the Forsmark 2.3 dataset, which had its 'data freeze' on March 31, 2007. The present modelling is performed in support of the final version of the Forsmark site description that is produced during the site investigation phase. In this work, the hydrological modelling system MIKE SHE has been used to describe near-surface groundwater flow and the contact between groundwater and surface water at the Forsmark site. The surface ...

2008-09-15

305

Safe Water in an Emergency  

Medline Plus

English - Safe Water in an Emergency Click to Stop Video Click to Start Video To Listen to ...

306

Fault location observability analysis and optimal meter placement based on voltage measurements  

British Library Electronic Table of Contents (United Kingdom)

Various transmission line fault location algorithms have been proposed in the past depending on measurements available. These methods evince that if a sufficient number of meters are placed in a power network to record the fault measurements, then the fault location can be reliably estimated. A relevant question to ask may be: how many meters are sufficient in order to derive a reliable and unique fault location estimate for a given network? This paper addresses this question by defining and performing the fault location observability analysis. An optimal meter placement scheme is proposed for determining the optimal locations to place meters so as to make the system observable while minimizing the required number of meters to reduce costs. The proposed method is especially useful for powe...

2009-01-01

307

The Preliminary GAMMA Code Thermal hydraulic Analysis for the Steady State of HTR-10 Initial Core  

Energy Technology Data Exchange (ETDEWEB)

This report describes the preliminary thermalhydraulic analysis of HTR-10 steady state full power initial core to provide a benchmark calculation of VHTGR(Very High-Temperature Gas-Cooled Reactors) safety analysis code of GAMMA(GAs Multicomponent Mixture Analysis). The input data of GAMMA code are produced for the models of fluid block, wall block, radiation heat transfer and each component material properties in HTR-10 reactor. The temperature and flow distributions of HTR-10 steady state 10 MW{sub th} full power initial core are calculated by GAMMA code with boundary conditions of total reactor inlet flow rate of 4.32 kg/s, inlet temperature of 250 .deg. C, inlet pressure of 3 MPa, outlet pressure of 2.992 MPa and the fixed temperature at RCCS water cooling tube of 50 .deg C. The calculation results are compared with the measured solid material temperatures at 22 fixed instrumentation positions in HTR-10. The wall temperature distribution in pebble bed core shows ...

2006-07-15

308

Fall Chinook Aclimation Project; Pittsburg Landing, Captain John Rapids, and Big Canyon, Annual Report 2001.  

Energy Technology Data Exchange (ETDEWEB)

Fisheries co-managers of U.S. v Oregon supported and directed the construction and operation of acclimation and release facilities for Snake River fall Chinook from Lyons Ferry Hatchery at three sites above Lower Granite Dam. In 1996, Congress instructed the U.S. Army Corps of Engineers (USCOE) to construct, under the Lower Snake River Compensation Plan (LSRCP), final rearing and acclimation facilities for fall Chinook in the Snake River basin to complement their activities and efforts in compensating for fish lost due to construction of the lower Snake River dams. The Nez Perce Tribe (NPT) played a key role in securing funding and selecting acclimation sites, then assumed responsibility for operation and maintenance of the facilities. In 1997, Bonneville Power Administrative (BPA) was directed to fund operations and maintenance (O&M) for the facilities. Two acclimation facilities, Captain John Rapids and Pittsburg Landing, are located on the Snake River ...

2004-01-01

309

The Cytokinin Receptors of Arabidopsis Are Located Mainly to the Endoplasmic Reticulum1[W][OA]  

UK PubMed Central (United Kingdom)

The plant hormone cytokinin is perceived by membrane-located sensor histidine kinases. Arabidopsis (Arabidopsis thaliana) possesses three cytokinin receptors: ARABIDOPSIS HISTIDINE...Full Text Available

2011-08-01

310

Revision number 2 to test design description Volume IB, Part 2 (WHC-SP-0214) FSP-1R FFTF test assembly (HF191A)  

Energy Technology Data Exchange (ETDEWEB)

Based on changes to the fuel pin gas gap composition, pin location and assembly location, revisions to the TDD-IB, Part 2 are provided.

1989-07-14

311

Evidence for divided automatic attention  

Scientific Electronic Library Online (English)

Abstract in english A long-standing debate in the literature is whether attention can form two or more independent spatial foci in addition to the well-known unique spatial focus. There is evidence that voluntary visual attention divides in space. The possibility that this also occurs for automatic visual attention was investigated here. Thirty-six female volunteers were tested. In each trial, a prime stimulus was presented in the left or right visual hemifield. This stimulus was characteriz (more) ed by the blinking of a superior, middle or inferior ring, the blinking of all these rings, or the blinking of the superior and inferior rings. A target stimulus to which the volunteer should respond with the same side hand or a target stimulus to which she should not respond was presented 100 ms later in a primed location, a location between two primed locations or a location in the contralateral hemifield. ...

2008-02-01

312

49 CFR 236.206 - Battery or power supply with respect to relay; location.  

Science.gov (United States)

...2010-10-01 2010-10-01 false Battery or power supply with respect to relay...Signal Systems Standards § 236.206 Battery or power supply with respect to relay; location. The battery or power supply for each signal...

2010-10-01

313

Isotope fractionations and radiocarbon ages of beach rock samples collected from the Nansei Islands, southwest of Japan  

International Nuclear Information System (INIS)

Beach rocks are observed frequently on the tropical and subtropical sandy beaches where they express thin beds dipping seaward at less than 15 degrees. They consist of beach sediments including fossil shells, fragments of corals, diatoms and other biocarbonates, and are well cemented within the inter-tidal zone with calcium carbonate originated in sea water. Therefore, they are not only good indicators which show the past sea level, but also provide good sample material for radiocarbon dating. The locations of beach rocks give us an optimum condition studying a carbon cycle between land and marine environment by analyzing their isotope fractionations. In order to estimate the origin of calcium carbonate which worked as an adhesive when beach rocks were formed and to estimate the formative ages of beach rocks, a total of 330 fossil corals, fossil shells and calcarenite or calcirdite samples were collected from 128 sites of 16 islands consisting ...

2004-10-25

314

Busted Butte : final report on laboratory radionuclide migration experiments in non-welded tuff under unsaturated and saturated conditions  

International Nuclear Information System (INIS)

Three blocks of non-welded tuff, one nominally one cubic foot (trial block) in volume and the other two, nominally one cubic meter (1 m3) in volume, were excavated from the Busted Butte Test Facility on the Nevada Test Site in 1999 and transported to the Atomic Energy of Canada Limited Whiteshell Laboratories in Pinawa, Manitoba. The trial block and one of the 1-m3 blocks were used for radionuclide migration experiments under unsaturated conditions; the remaining 1-m3 block was used for similar migration experiments under saturated conditions. After a vertical flow of synthetic transport solution was set up under unsaturated conditions, a suite of conservative and chemically reactive radionuclide tracers was injected at volumetric flow rates of 20 mL/hr in the trial block, and 10 mL/hr in two locations on the upper surface of the 1-m3 block. These flow rates correspond to infiltration rates of about 120 cm/year and about 17 cm/year, respectively. The duration of ...

2005-09-13

315

Precision Actuator Systems Research at the University of ...  

Science.gov (United States)

... The Kanagawa Academy of Science and Technology (KAST) is located in the Kanagawa Science Park of the Kanagawa Prefecture about 30 miles ...

1993-08-23

317

Development of QTL Mapping Populations  

Science.gov (United States)

The objective of this animation is to develop a QTL mapping population for locating and characterizing the genes responsible for resistance to tan spot disease of wheat.

320

An application of possibilistic programming to the fuzzy location?allocation problems  

British Library Electronic Table of Contents (United Kingdom)

This paper considers location?allocation problem in the real uncertain world and develops a possibilistic non-linear programming model to deal with this problem. Fuzzy decision making in fuzzy environment concept is used to determine possibility distribution of location and allocation variables. To solve this model, a novel approach based on genetic algorithm structure is developed. As the proposed model includes both deterministic (location) and uncertain (allocation) parameters, the developed solution algorithm uses a hybrid chromosome structure. Also, to cover continuous nature of the problem and prevent GA from early convergence, a new crossover operator is introduced. Finally, performance of the developed algorithm is evaluated by an example.

2011-01-01

321

An accurate fault location on mutually coupled transmission lines using synchronized sampling  

Energy Technology Data Exchange (ETDEWEB)

The mutual inductance between parallel transmission lines influences the locating of the transmission line faults. A fault location algorithm for parallel lines developed in this paper takes into account the magnetic coupling between parallel lines. The paper presents a detailed description of the developed algorithm and test results performed on a simplified real transmission line. The obtained error is less than 0.5 percent in most cases. Also, the developed algorithm is not sensitive to typical fault parameters, such as: resistance, type, location, and incidence angle. 7 refs, 4 figs, 12 tabs

1995-12-31

322

Wireless Sensor Network based Future of Telecom Applications  

CERN Document Server

A system and method for enabling human beings to communicate by way of their monitored brain activity. The brain activity of an individual is monitored and transmitted to a remote location (e.g. by satellite). At the remote location, the monitored brain activity is compared with pre-recorded normalized brain activity curves, waveforms, or patterns to determine if a match or substantial match is found. If such a match is found, then the computer at the remote location determines that the individual was attempting to communicate the word, phrase, or thought corresponding to the matched stored normalized signal.

2010-01-01

323

Water resources data for Minnesota, water year 1993. Volume 2. Upper Mississippi and Missouri River basins. Water-data report (Annual), 1 October 1992-30 September 1993  

Energy Technology Data Exchange (ETDEWEB)

Water-resources data for the 1993 water year for Minnesota consists of records of stage, discharge and water quality of streams; stage, contents, and water quality of lakes and reservoirs; and water levels and water quality in wells and springs. This volume contains discharge records for 58 gaging stations; stage and contents for 9 lakes and reservoirs; water quality 15 stream stations, 1 lakes station, 1 precipitation station, and water levels for 15 observation wells. Also included are 61 high-flow partial-record stations. Additional water data were collected at various sites, not part of the systematic data collection program and are pulished as miscellaneous measurements.

1994-07-01

324

Water resources data for Minnesota, water year 1991. Volume 2. Upper Mississippi and Missouri River Basins. Water-data report (Annual), 1 October 1990-30 September 1991  

Energy Technology Data Exchange (ETDEWEB)

Water-resources data for the 1991 water year for Minnesota consist of records of stage, discharge and water quality of streams; stage, contents, and water quality of lakes and reservoirs; and water levels and water quality in wells and springs. The volume contains discharge records for 60 gaging stations; stage and contents for 9 lakes and reservoirs; water quality for 18 stream stations, 1 lake station, 22 partial-record sites, 1 precipitation station, 108 wells; and water levels for 119 observation wells. Also included are 59 high-flow partial-record stations. Additional water data were collected at various sites, not part of the systematic data collection program and are published as miscellaneous measurements or low-flow investigations.

1992-09-01

325

National Water Plan draft  

International Nuclear Information System (INIS)

In the National Water Plan it is described which measures must be taken to keep the Netherlands safe and livable for future generations and to make use of the chances offered by water.

326

CDC Data & Statistics | Feature: Drowning Risks in Natural Water...  

Science.gov (United States)

swimmers in or around the water. Designate a responsible adult who can swim and knows CPR to watch swimmers in or around water. The supervisor should not be involved in any...

2011-09-24

327

Between Place and Interface: Designing Situated Sound for the iPhone  

British Library Electronic Table of Contents (United Kingdom)

This article explores composition skills and modalities for locative, multimedia texts by reporting experiences from a locative iPhone application that plays church music and explains that music's history in churches in Rome, Italy. Using a research by design approach, we did three rounds of observation, paper sketches, and user testing of prototypes. We found that an effective locative text must be adapted to the place in which it is intended to be experienced. The locative text must be specific, possibly referring to what the audience can see or experience at the place, and thus it is important to know how people usually behave in that particular place. Images are of little relevance in a mobile guide, except for exterior shots, which may help users to locate interesting buildings. Sound...

2011-01-01

328

Aespoe Pillar Stability Experiment. Acoustic emission and ultrasonic monitoring  

Energy Technology Data Exchange (ETDEWEB)

This report describes the results from acoustic emission (AE) and ultrasonic monitoring of the Aespoe Pillar Stability Experiment (APSE) at SKB's Hard Rock Laboratory (HRL), Sweden. The APSE is being undertaken to demonstrate the current capability to predict spalling in a fractured rock mass using numerical modelling techniques, and to demonstrate the effect of backfill and confining pressure on the propagation of micro-cracks in rock adjacent to deposition holes within a repository. An ultrasonic acquisition system has provided acoustic emission and ultrasonic survey monitoring throughout the various phases of the experiment. Results from the entire data set are provided with this document so that they can be effectively compared to several numerical modelling studies, and to mechanical and thermal measurements conducted around the pillar volume, in an 'integrated analysis' performed by SKB staff. This document provides an in-depth summary of the AE and ...

2005-12-15

329

Use of numerical wind-wave models for assessment of the offshore wave energy resource  

Energy Technology Data Exchange (ETDEWEB)

In the last two decades the performance of numerical wind-wave models has improved considerably. Several models have been routinely producing good quality wave estimates globally since the mid-1980s. The verifications of wind-wave models have mainly focused on the evaluation of the error of the significant wave height H{sub s} estimates. However, for wave energy purposes, the main parameters to be assessed are the wave power P{sub w} and the mean (energy) period T{sub e}. Since P{sub w} is proportional to H{sub s}{sup 2}T{sub e}, its expected error is much larger than for the single-wave parameters. This paper summarizes the intercomparison of two wind-wave models against buoy data in the North Atlantic and the Mediterranean Sea to select the most suitable one for the construction of an Atlas of the wave energy resource in European waters. A full verification in the two basins of the selected model--the WAM model, implemented in the routine operation of the ...

1997-08-01

330

Use of microbes for paraffin cleanup at Naval Petroleum Reserve No. 3  

Energy Technology Data Exchange (ETDEWEB)

Naval Petroleum Reserve No. 3 (NPR-3), also known as Teapot Dome, is a government-owned oil field in Natrona County, Wyoming. It is an asymmetrical anticline located on the western edge of the Powder River Basin, just south of the Salt Creek Anticline. Production started in 1922, and today the field is a marginally economic stripper field with average production of less than 3 BOPD (0.5 m{sup 3}/D) per well. Total field production is about 1,800 BOPD (286 m{sup 3}/D). The Second Wall Creek Formation was waterflooded from 1979 until June 1992 with poor results due to the extensive natural fracture system in this sandstone unit. Since water injection ceased, reservoir pressure has declined to very low levels. Liquids extraction and reinjection of the gas produced from high-GOR wells along the gas-oil contact continues, but the average gas cap pressure has fallen to approximately 150 psi (1.03 MPa) from an original pressure of 1,120 psi (7.72 ...

1995-12-31

331

The importance of accurate crystal structure determination of uranium minerals. Pt. 1  

International Nuclear Information System (INIS)

On the basis of accurate crystal structure determination, the mineral phosphuranylite corresponds to the chemical formula KCa(H_3O)_3(UO_2)_7(PO_4)_4O_4.8H_2O. Cmcm, a=15.778 (3)-15.899(2), b=13.702(2)-13.790(5), c=17.253(3)-17.330(3)A, Z=4, D_x=4.575-4.631g cm"-"3, #mu#=287.6-291.1cm"-"1. The presence of potassium (about 1.80wt%K_2O), overlooked until now, has been confirmed by microprobe analysis on samples from four different localities. The best data for structure determination have been obtained by single-crystal X-ray diffraction on specimens from Capoterra, Sardinia, and Bois Noirs, France; here 1453 and 1254 independent reflections, respectively, were used in the refinement, and the corresponding final R index is 0.036 and 0.048. The structure consists of layers of phosphate groups connected with hexagonal, pentagonal and tetragonal dipyramids centered on the U atoms. The Ca and K atoms are located within channels in the uranylphosphate framework, together ...

332

Terra Nova FPSO on the Grand Banks of Canada  

Energy Technology Data Exchange (ETDEWEB)

An increased use of floating production facilities for offshore oil production in the past fifteen years was due in part to advances in technology, the opening of new frontiers and the increased emphasis on value driven development. Throughout the world, a total of 121 floating production systems were in operation in February 2001, and orders had been placed for an additional 27. Located near the nose of the Grand Banks, approximately 350 kilometres east-southeast of St. John's, Newfoundland is the Terra Nova development. Twelve years elapsed between the discovery of the field in 1984 and the granting of the approval for development in 1996. The decision was made to use a floating production system as the Terra Nova was not considered robust enough to support a gravity base, ice resistant structure development concept, especially considering that it came on the heels of the Hibernia development. The first Floating Production, Storage and Offloading (FPSO) ...

2001-07-01

333

Terra Nova Environmental effects monitoring program  

Energy Technology Data Exchange (ETDEWEB)

Elements of the environmental effects monitoring program in the Terra Nova oil field, about 350 km east-southeast of St. John's, Newfoundland, are described. This oilfield is being developed using a floating production storage and offloading (FPSO) facility. A total of 24 wells are expected to be drilled through seven subsea templates located in four glory holes to protect them from icebergs. Subsea installations will be linked to the FPSO by trenched flowlines connected to flexible risers. The FPSO will offload to shuttle tankers. First oil is expected in 2001. The environmental effects monitoring program will be conducted annually for the first two years beginning in 2000. Subsequent scheduling will be determined after a review of monitoring data collected during the first three years. Input to the design of the monitoring program was provided by all stakeholders, i. e. owners, local public, government agencies and regional and international experts. A ...

2000-07-01

334

Synopsis of moisture monitoring by neutron probe in the unsaturated zone at Area G  

Energy Technology Data Exchange (ETDEWEB)

Moisture profiles from neutron probe data provide valuable information in site characterization and to supplement ground water monitoring efforts. The neutron probe precision error (reproducibility) is found to be about 0.2 vol% under in situ field conditions where the slope in moisture content with depth is varying slowly. This error is about 2 times larger near moisture spikes (e.g., at the vapor phase notch), due to the sensitivity of the probe response to vertical position errors on the order of 0.5 inches. Calibrations were performed to correct the downhole probe response to the volumetric moisture content determined on core samples. Calibration is sensitive to borehole diameter and casing type, requiring 3 separate calibration relations for the boreholes surveyed here. Power law fits were used for calibration in this study to assure moisture content results greater than zero. Findings in the boreholes reported here confirm the broad features seen previously ...

1997-12-31

335

Spent Fuel Background Report Volume I  

Energy Technology Data Exchange (ETDEWEB)

This report is an overview of current spent nuclear fuel management in the DOE complex. Sources of information include published literature, internal DOE documents, interviews with site personnel, and information provided by individual sites. Much of the specific information on facilities and fuels was provided by the DOE sites in response to the questionnaire for data for spent fuels and facilities data bases. This information is as accurate as is currently available, but is subject to revision pending results of further data calls. Spent fuel is broadly classified into three categories: (a) production fuels, (b) special fuels, and (c) naval fuels. Production fuels, comprising about 80% of the total inventory, are those used at Hanford and Savannah River to produce nuclear materials for defense. Special fuels are those used in a wide variety of research, development, and testing activities. Special fuels include fuel from DOE and commercial reactors used in research activities at DOE ...

1994-03-01

336

Review of the WIPP draft application to show compliance with EPA transuranic waste disposal standards  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the New Mexico Environmental Evaluation Group (EEG) is to conduct an independent technical evaluation of the Waste Isolation Pilot Plant (WIPP) Project to ensure the protection of the public health and safety and the environment. The WIPP Project, located in southeastern New Mexico, is being constructed as a repository for the disposal of transuranic (TRU) radioactive wastes generated by the national defense programs. The EEG was established in 1978 with funds provided by the U.S. Department of Energy (DOE) to the State of New Mexico. Public Law 100-456, the National Defense Authorization Act, Fiscal Year 1989, Section 1433, assigned EEG to the New Mexico Institute of Mining and Technology and continued the original contract DE-AC04-79AL10752 through DOE contract DE-AC04-89AL58309. The National Defense Authorization Act for Fiscal Year 1994, Public Law 103-160, continues the authorization. EEG performs independent technical analyses of the ...

1996-03-01

337

Reprocessing of research reactor spent nuclear fuel at the PA ''Mayak''  

International Nuclear Information System (INIS)

The first Russian reprocessing facility, known as RT-1 (located at PA-Mayak in Ural region) was started on the radiochemical plant base in 1977. Nowadays RT-1 is the sole operating reprocessing plant in Russia. The main features of RT-1 is its broad spectrum of reprocessing spent nuclear fuels (SNF). The following spent fuel types are reprocessed: -) SNF from PWR reactors (WWER-440) and FB reactor (BN-600); -) SNF of transport ship reactors; -) production reactors SNF; -) research reactor spent nuclear fuel. The world-known technological processes are used at RT-1, but there are the following distinctive features. First, the universality of the three technological lines which allows not only the reprocessing of various SNF kinds, but also to implement the combined reprocessing of some types of them. Secondly, extraction of neptunium during SNF reprocessing which is used to implement its separate storage and for radioisotope production. Thirdly, target enrichment of ...

2007-03-11

338

Reprocessing of research reactor spent nuclear fuel at the PA 'Mayak'  

Energy Technology Data Exchange (ETDEWEB)

The first Russian reprocessing facility, known as RT-1 (located at PA-Mayak in Ural region) was started on the radiochemical plant base in 1977. Nowadays RT-1 is the sole operating reprocessing plant in Russia. The main features of RT-1 is its broad spectrum of reprocessing spent nuclear fuels (SNF). The following spent fuel types are reprocessed: -) SNF from PWR reactors (WWER-440) and FB reactor (BN-600); -) SNF of transport ship reactors; -) production reactors SNF; -) research reactor spent nuclear fuel. The world-known technological processes are used at RT-1, but there are the following distinctive features. First, the universality of the three technological lines which allows not only the reprocessing of various SNF kinds, but also to implement the combined reprocessing of some types of them. Secondly, extraction of neptunium during SNF reprocessing which is used to implement its separate storage and for radioisotope production. Thirdly, target enrichment of ...

2007-07-01

339

Rainfall effect on single-vehicle crash severities using polychotomous response models.  

Science.gov (United States)

As part of the Wisconsin road weather safety initiative, the objective of this study is to assess the effects of rainfall on the severity of single-vehicle crashes on Wisconsin interstate highways utilizing polychotomous response models. Weather-related factors considered in this study include estimated rainfall intensity for 15 min prior to a crash occurrence, water film depth, temperature, wind speed/direction, stopping sight distance and deficiency of car-following distance at the crash moment. For locations with unknown weather information, data were interpolated using the inverse squared distance method. Non-weather factors such as road geometrics, traffic conditions, collision types, vehicle types, and driver and temporal attributes were also considered. Two types of polychotomous response models were compared: ordinal logistic and sequential logistic regressions. The sequential logistic regression was tested with forward and backward ...

2009-08-14

340

Radiofrequency electromagnetic fields in the Cookridge area of Leeds  

Energy Technology Data Exchange (ETDEWEB)

On the 8 and 9 May 2002 representatives of the National Radiological Protection Board (NRPB) performed a radiofrequency electromagnetic field survey in the Cookridge area of Leeds in order to assess exposure to radio signals from transmitters mounted on a water tower/a lattice tower and a radio station tower. Guidelines on limiting exposure to radio signals have been published by NRPB and the International Commission on Non-Ionizing Radiation Protection (ICNIRP). These guidelines are designed to prevent established adverse effects on human health. During this survey, the total exposures due to all radio signals from 30 MHz to 18000 MHz (18 GHz) were measured. This frequency range was chosen as it includes mobile phone base station transmissions, which are at around 900 and 1800 MHz and super high frequency (SHF) transmissions from most of the large microwave dish antennas mounted on the towers. In addition, other major sources of radiofrequency electromagnetic ...

2002-07-01

341

Partitioning of trace metals in the chemical fractions of bed-load sediments of Nahr-Ibrahim river, Lebanon  

International Nuclear Information System (INIS)

Full text.Sediments are the ultimate sink of trace elements. The total metal analysis may only give information concerning possible enrichment of metals. The analysis of metal partitioning in the different chemical components of sediments (exchangeable, carbonate, easily reducible, moderately reducible, organic and residual); give a detailed information on the way in which these metals are bound to sediments, their mobilization capacity and their ability to affect water quality under different environmental conditions. The studied river basin is dominated by limestone formation, the enrichment of metals in the carbonate sediment fraction is a high probability. The objective of the study was to determine the percentage of the total metal content (Fe, Mn, Zn, Cu and Pb) in the six chemical fractions of the bed load sediments of Nahr-Ibrahim river during the dry season and verify the role of carbonate for metal sediment deposition. Bed load sediments were sampled at ...

1999-11-02

342

Net ecosystem CO{sub 2} exchange of a cutover peatland rehabilitated with a transplanted acrotelm  

Energy Technology Data Exchange (ETDEWEB)

Peatlands are an important long-term sink for atmospheric carbon dioxide (CO{sub 2}). The storage function of peatland ecosystems is significantly impacted by drainage and extraction processes, which can result in the release of significant amounts of CO{sub 2}. This paper investigated the net ecosystem CO{sub 2} exchange of a newly developed extraction-restoration technique that preserved the acrotelm and replaced it directly on the cut surface of the peatlands. The technique used a modified block-cut method with a back-hoe to create a drainage ditch. Actrotelm and surface vegetation were removed and placed to one side, and the peat was mechanically removed. The acrotelm was then transplanted over the older and more decomposed catotelm peat to create a trench topography in which the natural peatland was higher than the extracted zone. Air temperatures, water table levels, and volumetric moisture content levels were measured throughout the experiment. Measurements ...

2008-07-01

343

Historical trends in the accumulation of chemicals in Puget Sound sediment  

International Nuclear Information System (INIS)

As human activity in and around Puget Sound increased, so did the contaminant levels in the sediment. Sediment cores collected in 1 982 revealed inputs of chemicals to the Sound, including lead (Pb), mercury (Hg), silver (Ag), copper (Cu) and petroleum hydrocarbons, began to increase above background in the late 1800s and peaked between 1945 and 1965. Synthetic organic compounds, such as polychlorinated biphenyls (PCBs) and DDT, first appeared in sediments deposited in the 1930s and reached a maximum in the 1960s. The presence of the subsurface maximum concentrations suggests that pollution-control strategies have improved the sediment quality of central Puget Sound. Additional sediment coring was performed in 1991 and samples were collected at six locations in the main basin of Puget Sound. Sediment ages were determined using Pb"2"1"0 radio isotope dating. Sedimentation rates were approximately 1 to 2 cm/yr and deposition rates ranged from 480 to 1000 mg/cm2/yr. ...

1995-11-05

344

Heat transfer performance of a fin with two fences and tube heat exchanger. Study in the low Reynolds number range; Fence wo fusetsushita fin tsuki kan netsu kokanki unit no ryudo dennetsu sogo tokusei. Tei Reynolds suiki ni okeru kosatsu  

Energy Technology Data Exchange (ETDEWEB)

A three-dimensional steady numerical computation was made for a component model of fin and tube type of compact heat exchangers situated in a uniform flow. In this study, in order to find a clue to design high-efficient heat exchangers, numerical computation was made in the case where two fences are attached on the plate fin surface and their geometrical effects such as their locations, their heights and their attack angles on flow and heat transfer characteristics were investigated especially in the low Reynolds number range. The effect of a hole, open in the plate fin behind the fence, on heat transfer and flow structures was also examined. This hole simulates the hole of the plate fin to be produced in practical application, when a fence is produced by punching from the original plain fin plate. Two fences with holes were found to show several important effects on flow and heat transfer structures and to work well in heat transfer augmentation. They reduce the ...

2000-07-25

345

Glacier changes in the Siberian Altai Mountains, Ob river basin (1952-2006) estimated with high resolution imagery  

Energy Technology Data Exchange (ETDEWEB)

The Siberian Altai covers about 70% of the area of all south Siberian glaciers, which provide fresh water to the upper tributaries of the Ob and Yenisey rivers. The observed air temperature has increased by 1.2 deg. C over northern Eurasia during the last 120 years, affecting the degradation of the Siberian Altai glaciers. In this study, we estimated glacier area changes in the Aktru River basin (44.8 km{sup 2}), located in the central Altai mountains. We used the 1952, 1966, 1975 and 2006 remote sensed images with 0.6-3.0 m spatial resolution (aerial photographs, Corona and PRISM satellite images) and differential GPS (DGPS) data. From 1952 to 2006, the total glacier area in the Aktru basin shrank by 7.2% (1.2 km{sup 2}). During the last three decades, the rate of glacier area loss increased by a factor of 1.8, thus resembling trends in other mountain systems of Eurasia (Alps, Tien Shan). The glacier area changes were caused mainly by increase ...

2007-10-15

346

Glacier changes in the Siberian Altai Mountains, Ob river basin (1952-2006) estimated with high resolution imagery  

International Nuclear Information System (INIS)

The Siberian Altai covers about 70% of the area of all south Siberian glaciers, which provide fresh water to the upper tributaries of the Ob and Yenisey rivers. The observed air temperature has increased by 1.2 deg. C over northern Eurasia during the last 120 years, affecting the degradation of the Siberian Altai glaciers. In this study, we estimated glacier area changes in the Aktru River basin (44.8 km"2), located in the central Altai mountains. We used the 1952, 1966, 1975 and 2006 remote sensed images with 0.6-3.0 m spatial resolution (aerial photographs, Corona and PRISM satellite images) and differential GPS (DGPS) data. From 1952 to 2006, the total glacier area in the Aktru basin shrank by 7.2% (1.2 km"2). During the last three decades, the rate of glacier area loss increased by a factor of 1.8, thus resembling trends in other mountain systems of Eurasia (Alps, Tien Shan). The glacier area changes were caused mainly by increase of summer ...

347

Genetic analysis of carbon isotope discrimination and its relation to yield in a wheat doubled haploid population.  

Science.gov (United States)

Carbon isotope discrimination (?(13) C) is considered a useful indicator for indirect selection of grain yield (GY) in cereals. Therefore, it is important to evaluate the genetic variation in ?(13) C and its relationship with GY. A doubled haploid (DH) population derived from a cross of two common wheat varieties, Hanxuan 10 (H10) and Lumai 14 (L14), was phenotyped for ?(13) C in the flag leaf, GY and yield associated traits in two trials contrasted by water availability, specifically, rain-fed and irrigated. Quantitative trait loci (QTLs) were identified by single locus and two locus QTL analyses. QTLs for ?(13) C were located on chromosomes 1A, 2B, 3B, 5A, 7A and 7B, and QTLs for other traits on all chromosomes except 1A, 4D, 5A, 5B and 6D. The population selected for high ?(13) C had an increased frequency of QTL for high ?(13) C, GY and number of spikes per plant (NSP) when grown under rain-fed conditions and only for high ?(13) C and NSP ...

2011-09-01

348

Gas emergency management - safety and reliability of supply - remote management of distribution system through computer assisted dispatching of emergency events; Gestion des urgences - securite et fiabilite de la distribution du gaz gestion des urgences a l'aide d'un systeme informatique integre  

Energy Technology Data Exchange (ETDEWEB)

Gas distribution companies have long since paid great attention to improving the quality and safety of the gas supply service to the consumer. In particular the management of gas emergencies has always been a responsibility taken seriously by all sectors of the gas industry. Over the last few years, however, the concept and practices in risk management have been changing rapidly. This has involved gas companies in an on-going attempt to successfully define and establish clear computer assisted risk management practices. Risk management is the systematic use of management policy, procedures and means, with the aim to protect employees, the public, the environment and properties at an acceptable cost. This paper has the purpose of presenting: - the computer software of gas emergency management in use at Italgas S.p.A. for testing the performance of gas distribution networks on a 'real-time' basis and therefore selecting effective action for solving any emergency that ...

2000-07-01

349

First oil expected at White Rose in 2005  

Energy Technology Data Exchange (ETDEWEB)

Husky Oil received approval from the government to begin development of its White Rose properties located in the Jean d'Arc Basin, 350 km east of St. John's, offshore Newfoundland and Labrador. First oil is expected by the end of 2005. The South Avalon Pool was discovered in 1988 and is estimated to contain approximately 200-250 million barrels of oil. Husky Oil and Petro-Canada filed a development application with the Canada-Newfoundland Offshore Petroleum Board in January 2001. Approval of the $2.35 billion project was received in December 2001. The development plan is based on a newly-built floating production, storage and offloading (FPSO) vessel. Initial development will focus on the South Avalon Pool that has been tested in excess of 5,000 barrels per day. The pool will be developed using eight production wells, 11 water injection wells and two gas injection wells. An estimated 150 million cubic feet per day of gas will ...

2002-04-01

350

Factors affecting the development of the pressure differential in Upper Paleozoic gas reservoirs in the Sulige and Yulin areas of the Ordos Basin, China  

Energy Technology Data Exchange (ETDEWEB)

The Sulige gas field and the Yulin gas field are located in the north of the Ordos Basin. Reservoir pressure in the Sulige area is subnormal, whereas reservoirs in the Yulin area have normal hydrostatic pressure. This paper provides an explanation of this difference. The characteristics of reservoir sediment and formation water chemistry in the gas reservoirs of these two areas were analyzed. The results showed that both reservoirs have good sealing ability. Data of numerical simulation showed that tectonic uplift resulted in a great reduction in formation pressure in the northern Ordos Basin during the late Cretaceous period, and the decrease was greater in the Yulin gas field than in the Sulige gas field. However, because the total hydrocarbon-generating intensity of the Sulige area (< 24 x 10{sup 8} m{sup 3}/km{sup 2}) was less than that of the Yulin area (> 32 x 10{sup 8} m{sup 3}/km{sup 2}), the gas supply intensity of the ...

2011-01-01

351

Elemental compositions of sediments at Haiphong harbour area as determined by nuclear analytical techniques application in sediment transport studies and conservation of the environment  

International Nuclear Information System (INIS)

Nuclear analytical techniques were applied to determine the elemental compositions of suspended and bottom sediments, collected at different sites in Haiphong harbor area (North Viet nam). The study was aimed at: 1/Understanding the origin of the sediment filling up the access channel and causing large expenditures for dredging operations. 2/Determining the background concentrations of trace elements in sediment. This would allow to detect in the future any pollution caused by the discharge of industrial wastes in the water due to the growing industrialization of the area. 3/Identifying the elements, which can be served as activatable tracers in sediment transport studies. The results obtained for the concentrations of nearly 30 elements show rather similar elemental compositions, reflecting a common origin of the sediments taken from different locations in the harbour area. The results could not allow to identify the pathway of the sediment ...

1992-03-09

352

Depositional setting of the Upper Jurassic Hith Anhydrite of the Arabian Gulf: An analog to holocene evaporites of the United Arab Emirates and Lake MacLeod of Western Australia  

Energy Technology Data Exchange (ETDEWEB)

The Upper Jurassic Hith Anhydrite is a major hydrocarbon seal in the Arabian Gulf region. Outcrops, core samples from the subsurface, and the literature indicate that the Hith Formation is composed mainly of anhydrite. In most locations where a section of the Hith Formation has been measured, this unit contains less than 20% carbonate much of which is in the form of thin laminations. This lack of carbonate, locally thick layers of salt, and the predominance of anhydrite favor a playa for the setting in which this sediment was accumulated. In fact, much of the Hith has the sedimentary characteristics of the Holocene Lake MacLeod playa of Western Australia, which is dominated by layers of gypsum and halite (what little carbonate that occurs is found in layers at the base of the section). Locally the Hith appears to have accumulated in a sabkha setting, particularly toward central Abu Dhabi where it pinches out into shallow-water, and peritidal ...

1994-07-01

353

Data Center Energy Benchmarking: Part 4 - Case Study on aComputer-testing Center (No. 21)  

Energy Technology Data Exchange (ETDEWEB)

The data center in this study had a total floor area of 8,580 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 440 racks, and was located in a 208,240 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but served by the main building chiller plant and make-up air system. Additionally, it was served by a single electrical supply with no provision for backup power. The data center operated on a 24 hour per day, year-round cycle, and users had all hour full access to the data center facility. The study found that data center computer load accounted for 23% of the overall building electrical load, while the total power consumption attributable to the data center including allocated cooling load and lighting was 30% of the total facility load. ...

2007-08-01

354

Archive monitoring of pollutants in the Dee River using SIMS analysis of mussels  

International Nuclear Information System (INIS)

Full text: Mt Morgan was mined for copper and gold from 1882 to 1982 and subsequent tailings re-processing ceased in 1990. Direct and accidental deposition of tailings into the adjacent Dee River and acid mine drainage from the mine site continues to impact the Dee River. The Queensland Department of Natural Resources gauging and monitoring station at Kenbula (adjacent to the mine) continuously monitors pH of around 2.8. Twenty kilometres downstream of the mine the pH improves to 3.5. Elevated sediment metal concentrations have been recorded over 50 kilometres downstream in investigations conducted by CSIRO (Jones et al. 1995, 1996) and others. Biological monitoring by Mackey (1988) and subsequently by Duivendoorden (1995,1997), confirmed significant impact on the fish, macrophyte of macro invertebrate populations downstream of the mine. The current AINSE sponsored project will investigate the use of mussels (genus Allathryia) to archive the pollutant load in the Dee River using SIMS. ...

2000-11-29

355

Transport of sorbing solutes in randomly heterogeneous formations: Spatial moments, macrodispersion, and parameter uncertainty  

Energy Technology Data Exchange (ETDEWEB)

Expressions for the spatial moments and macrodispersion tensor for sorbing solutes in heterogeneous formations were presented using a probabilistic model of a fluid residence time coupled with the particle position analysis. The fluid residence time was defined as a fraction of the actual time during which the particle stayed in the mobile fluid phase of the aquifer. The fluid residence time is a random variable whose variability comes as a result of the non-equilibrium sorption properties. The sorbing solute was assumed to be governed with first-order linear kinetics. The closed-form expressions were based on the stationarity in the kinetic process and on the first-order approximation in the hydraulic conductivity field and in the fluid residence time. The non-equilibrium effects were presented as a function of the spatial variability in hydraulic conductivity and temporal variability in the fluid residence time. The importance of the non-equilibrium processes in ...

1993-06-01

360

Turbidimetric determination of sulfite ion in inhibited ethylene glycol-water solutions  

Science.gov (United States)

Turbidimetric method for determining sulfite in inhibited ethylene glycol-water solutions

1970-01-01

361
362

REPORT NO. 853  

Science.gov (United States)

water and of the ethylene glycol-water solutions are shown as functions of temperature in figures 4 and 5, respectively. (data from reference 4). ...

363

Process for reducing the water content of coal containing bound water  

Energy Technology Data Exchange (ETDEWEB)

An improved process is disclosed for reducing the water content of coal containing bound water by releasing at least a portion of the bound water by maintaining the coal at a temperature from about 220/sup 0/ to about 500/sup 0/ F. in the presence of water at a pressure sufficient to maintain at least portion of the water in a liquid phase for a time sufficient to release at least a portion of the bound water wherein the improvement comprises contacting the coal during such treatment with an active material selected from the group consisting of carboxylic organic acids containing up to about 6 carbon atoms, phenol, phenolic acids and inorganic acids.

1983-08-23

364

Energy and Water Conservation  

Science.gov (United States)

Jet Propulsion Laboratory. California Institute of Technology. Pasadena, California. Energy and Water Conservation. Steve Rigdon. Facilities Energy Manager ...

365

Combustible Water Repellent Coating.  

Science.gov (United States)

... Descriptors : *Combustible cartridge cases, *Water repellents, *Protective coatings, *Patents, Silica gel, Aluminum compounds, Binders ...

1973-07-24

366

Husky Oil's White Rose gets ready to bloom  

Energy Technology Data Exchange (ETDEWEB)

The South White Rose oilfield, offshore Newfoundland, owned jointly by Husky Oil (82.5 per cent ) and Petro-Canada (17.5 per cent) is being developed using a floating production storage and offloading (FPSO) system. Some industry stakeholders claim that the oil should be produced using a concrete gravity base system as used in the Hibernia Field. However, Husky Oil officials are confident that the choice of the FPSO is well justified, based on its cost effectiveness and economic viability. Several production facility options have been assessed, taking into account feasibility, deliverability, economic attributes. risk and safety . The assessment results clearly pointed to FPSO as the preferred system based on its commercial and technical flexibility, proven track record in harsh environments, its ability to produce both oil and gas in sequential development, its promise of production at full capacity earlier than a gravity base system, and easier decommissioning than a GBS-type fixed ...

2000-06-01

367

Water chemistry and corrosion in water-steam circuits of nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

The water and steam circuits of steam generators in pressurized-water nuclear power plants are described together with the mechanism of denting, and the corrosion of spacer plates that leads to cracks in tubes by constriction. The different chemical specifications applicable to the water of the secondary circuit of the generators in normal operation and on first commissioning are listed. The results obtained and the measurements of chemical values taken in operation on the water in the secondary circuits of steam generators at Fessenheim and Bugey are presented.

1981-05-01

368

Water chemistry and corrosion in water-steam circuits of nuclear power plants  

International Nuclear Information System (INIS)

The water and steam circuits of steam generators in pressurized-water nuclear power plants are described together with the mechanism of denting, and the corrosion of spacer plates that leads to cracks in tubes by constriction. The different chemical specifications applicable to the water of the secondary circuit of the generators in normal operation and on first commissioning are listed. The results obtained and the measurements of chemical values taken in operation on the water in the secondary circuits of steam generators at Fessenheim and Bugey are presented.

369

Grid-Search Location Methods for Ground-Truth Collection from Local and Regional Seismic Networks  

Energy Technology Data Exchange (ETDEWEB)

The objective of this project is to develop improved seismic event location techniques that can be used to generate more and better quality reference events using data from local and regional seismic networks. Their approach is to extend existing methods of multiple-event location with more general models of the errors affecting seismic arrival time data, including picking errors and errors in model-based travel-times (path corrections). Toward this end, they are integrating a grid-search based algorithm for multiple-event location (GMEL) with a new parameterization of travel-time corrections and new kriging method for estimating the correction parameters from observed travel-time residuals. Like several other multiple-event location algorithms, GMEL currently assumes event-independent path corrections and is thus restricted to small event clusters. The new parameterization assumes that travel-time ...

2003-07-24

370

The technical-economic potential of thermal energy saving in hospitals; El potencial tecnico-economico de ahorro de energia termica en hospitales  

Energy Technology Data Exchange (ETDEWEB)

The hospitals are important consumers of energy. At the General Hospital of Zone (HGZ) N of the IMSS in Aguscalientes (HGZ N . IMSS Ags.), the diesel oil is the main fuel that is used to satisfy the requirements of thermal energy of the hospital. According to the data collected by this author, this fuel represented in 2001, 75% of its total energy consumption and the 67.9% of its total costs in energy that ascended to $396.131 (December 2001 Dollars) Since this last amount represents an important percentage of the total expenses of the hospital (29.367 million dollars) it is important to determine the technical-economic possibilities of thermal energy saving of the hospital. The HGZ N 1 IMSS Ags. is located in a ampler conglomerate where the IMSS units are located, such as, the regional laundry, the sport unit, the center of social security, the familiar medicine unit N 1 and the hospital. Nevertheless departing from the installation of the ...

2001-07-01

371

Cooling facility for reactor container  

International Nuclear Information System (INIS)

Cooling water is sprayed on the outer surface of an upper portion of a container, and a pool is formed by the cooling water flowing down while cooling the container. Further, the cooling water stored in the cooling water pool is recycled by a pump for spraying the cooling water on the outer surface of the upper portion of the container. Sufficient amount of cooling water is supplied for spraying the cooling water to the outer surface of the upper portion of the container so that the outer surface of the container is free from drying and a liquid membrane is formed on the entire surface. The amount of the cooling water is made greater than that of the cooling water evaporated when the entire amount of the heat generate in the reactor core of the reactor is transferred to the cooling ...

1993-05-07

372

Development of a leak location system for use on underground electric power transmission cable. Final report  

Energy Technology Data Exchange (ETDEWEB)

This report describes a study to evaluate methods for locating leaks of dielectric fluid from buried high-voltage cable systems. Two primary types of leak location systems were investigated: (1) systems that will rapidly isolate the leak within a manhole section, typically 1000-m long on a feeder that might be 30-km long; and (2) systems that will then pinpoint the location of the leak. Rapid leak isolation was accomplished by developing an enhanced conductivity oil probe which allows the injection of a small quantity of conductive oil and which indicates the path of the oil as it drifts downstream in the direction of the leak. Two methods for pinpointing the leak were proven. The more successful method was the use of trained leak location dogs which were found to have far better sensitivity than instruments and which could detect cable oil alone without the need for additives. A tracer gas injection ...

1982-10-01

373

Water resources data for Texas, water year 1993. Volume 3. Colorado River basin, Lavaca River basin, Guadalupe River basin, Nueces River basin, Rio Grande basin, and intervening coastal basins. Water-data report (Annual), 1 October 1992-30 September 1993  

Energy Technology Data Exchange (ETDEWEB)

Water-resources data for the 1993 water year for Texas are presented in four volumes, and consist of records of stage, discharge, and water quality of streams and canals; and stage, contents, and water quality of lakes and reservoirs; and water levels and water quality of ground-water wells. Volume 3 contains records for water discharge at 134 gaging stations; stage only at 1 gaging stations; stage and contents at 13 lakes and reservoirs; water quality at 81 gaging stations; and data for 30 partial-record and 4 flood-hydrograph partial-record stations. Also included are lists of discontinued surface-water discharge or stage-only stations and discontinued surface-water-quality stations; crest-stage and flood-hydrograph partial-record stations, reconnaissance ...

1994-03-01

374

Mathematical child phantom for the calculation of dose to the organs at risk  

Energy Technology Data Exchange (ETDEWEB)

In order to calculate the doses received by the organs of 530 children treated by radiation for cancer between 1945 and 1969 at the G. Roussy Institute, we have developed a computer program for organ location calculation. To calculate the location of each child's organs of interest at the time of the treatment, only two parameters are necessary; sex and height or sex and age when the height at the time of the treatment is unknown. The algorithm is based on the metric studies of growth known as auxology. Each organ is located by one point representing its center. The model has been checked on 100 healthy children.

1988-05-01

375

Ground temperatures surrounding a molten fuel pool  

International Nuclear Information System (INIS)

In the analysis of the consequences of a hypothetical meltdown accident in an LMFBR, it is important to estimate the final location of the molten fuel pool in the concrete and ground underlying the reactor vessel. The GROWS program and the AYER program have been developed to calculate the final location of the molten fuel pool as the culmination of the transient analysis of this unusual Stefan problem but these programs require extensive computational resources. The solution is provided to the concrete and ground temperatures surrounding the stationary fuel pool and the related heat flux from the pool to the ground surface outside the containment building. This solution can be used to estimate the final location of the fuel pool and to check the end results of the sophisticated programs.

1977-06-01

376

Interaction of water with epoxy.  

Energy Technology Data Exchange (ETDEWEB)

The chemistries of reactants, plasticizers, solvents and additives in an epoxy paint are discussed. Polyamide additives may play an important role in the absorption of molecular iodine by epoxy paints. It is recommended that the unsaturation of the polyamide additive in the epoxy cure be determined. Experimental studies of water absorption by epoxy resins are discussed. These studies show that absorption can disrupt hydrogen bonds among segments of the polymers and cause swelling of the polymer. The water absorption increases the diffusion coefficient of water within the polymer. Permanent damage to the polymer can result if water causes hydrolysis of ether linkages. Water desorption studies are recommended to ascertain how water absorption affects epoxy paint.

2009-07-01

377

European Commission - Environment  

Wastenet

...Species - see CITES Trade of Dangerous Chemicals Transport and Environment U Urban Environment Use of natural resources V Volatile Organic Compounds W Waste Landfills Waste electrical and electronic equipment - see WEEE Waste incineration Waste legislation - reporting Waste management planning Waste oils Waste shipments Waste water - see Urban waste water Water Bathing Water Drinking water Floods Marine environment Urban waste water Water Framework Directive WEEE - Waste Electric and Electronic Equipment Wildlife ...

378

Underground reservoirs for high-head pumped-storage stations  

Science.gov (United States)

The advantages of using heads of around 1000 m in conjunction with underground location of the lower reservoirs for pumped storage plants are described, and the possible layouts, equipment, and construction methods are discussed.

1973-03-01

379

USAID Policy: Competitive Sourcing  

Science.gov (United States)

Skip to main content About USAID Locations Our Work Public Affairs Careers Business / Policy USAID: From The American People Policy USAID's 50th Anniversary Policy Home »...

2011-09-25

380

U.S. Fish and Wildlife Service Home  

Science.gov (United States)

Lake Unit AL-05P, for public review and comment. These four CBRS units are located in Baldwin and Mobile Counties, Alabama. We invite the public to review and comment on the draft...

2011-09-14

381

Transforming Clinic Environments into Information Workspaces for Patients  

UK PubMed Central (United Kingdom)

Although clinic environments are a primary location for exchanging information with clinicians, patients experience these spaces as harsh environments to access, use, exchange, and manage information....Full Text Available

2010-01-01

382

Traffic Signs at Colorado National Monument, Colorado  

Science.gov (United States)

This is a point shapefile showing Traffic sign locations at Colorado National Monument. The coordinates for this dataset were collected using a Trimble Geo-Explorer 2 GPS reciever....

383

The world's coastline  

Energy Technology Data Exchange (ETDEWEB)

This is the first documentation of coastal geomorphology on a global scale. It locates, describes, and illustrates geomorphological features of particular interest from the coastline of the entire world.

1985-01-01

384

The Management of Pit Viper Envenomation of the Hand  

UK PubMed Central (United Kingdom)

Snakebites are common among the rural population of developing countries. The severity of venomous snakebites depends on several factors, including the location of the bite, the amount of venom injected,...Full Text Available

2008-12-01

385

The Landsat Program - Images  

Science.gov (United States)

On April 20, 2010 the Deepwater Horizon offshore drilling rig located in the Gulf of Mexico experienced an explosion resulting in at least 11 deaths and creating ...

386

The Effect of Experience on Male Courtship and Mating Behaviors in a Cellar Spider  

Science.gov (United States)

... video recorded in an isolated booth under a Panasonic WV-CP470 video camera located in an environmentally ... ...

387

Teleogramma gracile  

Science.gov (United States)

... Congo. It is probable that the type locality Matadi is in error and is the location from ... specimens of this species have been collected between Matadi and Luozi. (click map to view...

388

Space Images - NASA Jet Propulsion Laboratory  

Science.gov (United States)

Jan 18, 2011 ... The Radiation Assessment Detector, shown prior to its September 2010 ... This 360-degree panorama shows the vista from the location where ...

389

Skin as an endocrine organ: implications for its function  

UK PubMed Central (United Kingdom)

Described as the body's largest organ, the skin is strategically located at the interface with the external environment where it has evolved to detect, integrate and respond to a diverse range...Full Text Available

2008-06-01

390

Sacral haemangioma as a cause of coccydynia  

International Nuclear Information System (INIS)

We report a 55-year-old woman with coccydynia due to a sacral mass. The histological diagnosis was haemangioma. The MRI findings and the unusual location of this lesion are discussed. (orig.)

1998-08-01

391

Quality of Surgical Instruments  

UK PubMed Central (United Kingdom)

INTRODUCTIONMany surgeons will have encountered the scissors that would not cut, and the artery clip that comes off in a deep difficult location, but it would be reasonable to assume...Full Text Available

2006-07-01

392

Public Health Assessment - Bangor Naval Submarine Base and Bangor Ordnance Disposal (US Navy) - Silverdale, Kitsap ...  

Science.gov (United States)

Naval Submarine Base, Bangor (Bangor) is located on the Kitsap Peninsula along the east shore of Hood Canal in ... ...

393

Peritonectomy procedures.  

UK PubMed Central (United Kingdom)

OBJECTIVE: New surgical procedures designed to assist in the treatment of peritoneal surface malignancy were sought. BACKGROUND: Decisions regarding the treatment of cancer depend on the anatomic location...Full Text Available

1995-01-01

394

Iran 01/26/05  

Science.gov (United States)

Jan 26, 2005 ... Heavy snow settled over Iran on January 23, 2005, closing roads and ... Located along the southern front of the Alborz mountains, Iran's ...

395

Industrial Location at the Intra-Metropolitan Level: The Role of Agglomeration Economies  

British Library Electronic Table of Contents (United Kingdom)

Arauzo-Carod J.-M. and Viladecans-Marsal E. Industrial location at the intra-metropolitan level: the role of agglomeration economies, Regional Studies. The objective of this paper is to analyse the influence of agglomeration economies on location decisions taken by new firms inside metropolitan areas. As it is assumed that these economies differ according to firms' level of technology, the sample comprises new firms from high-, intermediate- and low-technology industries. Of particularly interest is in analysing the effects of agglomeration economies that are felt over very short distances (inside the metropolitan areas). Introduced in the estimation is the effect of the central city as a determinant for the location of new firms in the rest of the metropolitan area. [image omitted] Arauzo...

2009-01-01

396

Hypercalcemia  

Science.gov (United States)

... in the body. PTH is made by the parathyroid glands -- four small glands located in the neck behind ... is due to excess PTH release by the parathyroid glands. This excess occurs due to an enlargement of ...

397

Haplochromis fasciatus  

Science.gov (United States)

... from a single location. The growing cities of Matadi and Boma and maritime transportation, and the potential ... known only from the Lower Congo River, between Matadi and Boma. (click...

398

Computer Vision Hardware System for Automating Rough Mills of Furniture Plants  

Science.gov (United States)

... company. To automate this initial cutup requires a computer vision system that can locate and identify surface defects ... ...

399

Close to Transplant Renal Artery Stenosis and Percutaneous Transluminal Treatment  

UK PubMed Central (United Kingdom)

Purpose. To evaluate the efficacy of percutaneous transluminal angioplasty (PTA) in the management of arterial stenosis located close to the allograft anastomosis (close-TRAS)....Full Text Available

2011-01-01

400

Characterization of cry Genes in a Mexican Bacillus thuringiensis Strain Collection  

UK PubMed Central (United Kingdom)

Mexico is located in a transition zone between the Nearctic and Neotropical biogeographical regions and contains a rich and unique biodiversity. A total of 496 Bacillus thuringiensis...Full Text Available

1998-12-01

401

Cape Mendocino, CA Earthquakes, April 25 & 26, 1992 - NASA  

Science.gov (United States)

Two additional earthquakes, magnitudes 6.6 and 6.7 occurred the next morning. The first earthquake was located six miles north of Petrolia, California, ...

402

Phosphorus and nitrogen in the eutrophication of waters. Fosfori ja typpi vesien rehevoeittaejinae - vaikutusten arviointi  

Energy Technology Data Exchange (ETDEWEB)

This report is a summary of the contribution of nitrogen and phosphorus in the eutrophication process of inland and coastal waters. Special attention was paid to the mechanisms of these nutrients in regulating biological processes and to the methods available in estimating their effects in the eutrophication of water bodies. The report includes five chapters which are entitled: Introduction, which is a general background to the subject with special attention to the requirements of the Finnish Water Act. Phosphorus and nitrogen as factors regulating biological processes. The topics included are: definition of eutrophication, forms of phosphorus and nitrogen and their sources to inland and coastal waters, effects of these nutrients as growth factors of phytoplankton and macrophytes and consequences of eutrophication. Estimation of the effects of phosphorus and nitrogen. The topics discussed from the point ...

1992-01-01

403

On-farm water management in saline groundwater area under scarce canal water supply condition in the Northwest India  

British Library Electronic Table of Contents (United Kingdom)

The study investigates the possibility of enhancing crop water productivity in the parts of Northwest India where groundwater quality is marginal and canal water supply is severely scarce. Soil, Water, Atmosphere and Plant (SWAP) model was calibrated and validated in three farmers' fields with varying canal water availability and groundwater quality in the Kaithal Irrigation Circle of the Bhakra Canal system, Haryana. On the basis of predicted and observed soil water content, pressure heads, salt concentration at 2 week intervals and crop yields, the model was found suitable for use in the region. A few nomographs were prepared to provide a graphical method to predict the effect of different combinations of water quality and depth of water application on crop yield and soil salinity and to...

2008-01-01

404

Major roles of water chemistry for safe and reliable nuclear power plant operation. Research committee on water chemistry standard  

International Nuclear Information System (INIS)

The research committee of the Atomic Energy Society of Japan on water chemistry standard aims at establishing the private standard of water chemistry of nuclear power plants. The committee gathers up 'BWR water chemistry management manual', 'PWR primary system water chemistry management manual' and 'PWR water chemical analysis standard method', and furthermore aims at the standardization of those in future. Looking back on the committee's activities for the past four years, latest results of research of water chemistry mainly contributing to safe and reliable nuclear power plants were described with the future perspective of water chemistry and a demanded break-through. (T.T.)

2007-05-01

405

Laser-fluorescence determination of trace uranium in hot spring water, geothermal water and tap water in Xi'an Lishan region  

International Nuclear Information System (INIS)

Using the Laser-Fluorescence technique, an investigation was made, adopting the standard mix method, on trace uranium concentrations in hot spring water and geothermal water from Lishan region, and in tap water from some major cities in Shanxi province. Totally 40 samples from 27 sites were investigated. Measurement showed that the tap water contains around 10"-"6 g/L of uranium, whose concentrations in both hot spring water and geothermal water are 10"-"5 g/L. Most of samples are at normal radioactive background level, some higher contents were determined in a few samples

2002-03-01

406

Corrosion behavior of iron and nickel base alloys in high temperature and pressure water  

International Nuclear Information System (INIS)

In equipment industries, the equipments handling industrial water and pure water are numerous. In power generation including nuclear power generation, water serves as a working medium. Review is made on the experiences in the corrosion of iron and nickel base alloys in high temperature, high pressure water and the results of researches derived from them. Under high temperature and high pressure, carbon steel, low alloy steel, stainless steel and high nickel alloy cause corrosion even in pure water. But in the case of serious corrosion, chlorine, oxygen, alkali and others in water take part. The following matters are described: corrosion by steam; stress corrosion cracking in pure water; corrosion by impurities in high temperature, high pressure pure water, i.e. chlorine ions, dissolved oxygen, and alkali; corrosion under ...

407

AquaMagna Water Conditioner and Descaler  

Wastenet

...AquaMagna Water Conditioner and Descaler OCETA Environmental Technology & Business Profiles AQUAMAGNA WATER CONDITIONER AND DESCALER CAT. #03-018 CONTACT: Magna-Tek ...removal high-strength ceramic magnet no energy input The AquaMagna Water Conditioner and Descaler is a non-chemical method of water treatment. The technology uses ... Figure 1: The AquaMagna Water Conditioner and Descaler PROCESS/ PRODUCT APPLICATION: hard water domestic water process water reverse osmosis heat exchangers cooling ... For once-through or recirculating heating or cooling equipment, the AquaMagna descaler improves thermal efficiencies and reduces downtime. Figure 2 illustrates a cross-section ...

408

A novel domestic electric water heater model for a multi-objective demand side management program  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a novel domestic hot water heater model to be used in a multi-objective demand side management program. The model incorporates both the thermal losses and the water usage to determine the temperature of the water in the tank. Water heater loads are extracted from household load data and then used to determine the household water usage patterns. The benefits of the model are: (1) the on/off state of the water heater and temperature of the water in the tank can be accurately predicted, and (2) it enables the development of water usage profiles so that users can be classified based on usage behaviour. As a result, the amount of ancillary services and peak shaving that can be achieved are accurately predictable and can be maximized without adversely affecting users. (author)

2010-12-15

409

Spacer grid effects on post-CHF heat transfer in an annulus geometry  

Energy Technology Data Exchange (ETDEWEB)

The term 'Post-CHF' was generally used in the two-phase flow regime in tube flow occurring downstream of the CHF. It has various other names such as dispersed flow, liquid-deficient flow, mist flow and film boiling because the two-phase regime is characterized by a continuous vapor phase with discrete liquid drops and a non-wetted heated surface. The regime has been adopted in a lot of applications including nuclear power plants, fossil power plants, steam generators, refrigeration systems and spray cooling, In particular, this regime has a considerable importance in the areas of light water reactor(LWR) accident analysis (off-normal operating conditions) and design in heat exchangers operating in the once-through mode where subcooled liquid enters the exchanger and superheated vapor exits. Recently, innovative PWRs adopt very high power density increases and so require increased safety margins. For instance, advanced PWRs would be going to use a ...

2005-07-01

410

Spacer grid effects on post-CHF heat transfer in an annulus geometry  

International Nuclear Information System (INIS)

The term 'Post-CHF' was generally used in the two-phase flow regime in tube flow occurring downstream of the CHF. It has various other names such as dispersed flow, liquid-deficient flow, mist flow and film boiling because the two-phase regime is characterized by a continuous vapor phase with discrete liquid drops and a non-wetted heated surface. The regime has been adopted in a lot of applications including nuclear power plants, fossil power plants, steam generators, refrigeration systems and spray cooling, In particular, this regime has a considerable importance in the areas of light water reactor(LWR) accident analysis (off-normal operating conditions) and design in heat exchangers operating in the once-through mode where subcooled liquid enters the exchanger and superheated vapor exits. Recently, innovative PWRs adopt very high power density increases and so require increased safety margins. For instance, advanced PWRs would be going to use a new-type of spacer ...

2005-05-26

411

Water | Editorial Board  

Wastenet

...Tota-MaharajE-Mail: Interests: water and wastewater treatment, environmental engineering and sustainable systems; sustainable water management; sustainable urban drainage systems (SUDS); combined renewable energy applications with reverse osmosis desalination; microbial fuel cells for bioenergy production and treatment of urban wastewater; solar photocatalytic treatment and disinfection of water/wastewater Dr. Simon Toze CSIRO Land and Water, Queensland Bioscience Precinct - St Lucia, 306 Carmody Road, St Lucia QLD 4067,...

412

Changes in water dependence of Russian economy  

British Library Electronic Table of Contents (United Kingdom)

Indicators of source water use in different economic branches, water consumption in recycling and recycling-successive water supply in 1980?2006 are analyzed. Trends were identified in variations in specific water consumption in industry, agriculture, and municipal economy. Territorial differentiation of wetness indicators of regional product over federal districts and constituent territories of the RF is shown. Wetness values of gross domestic product in different economies are compared.

2010-01-01

413

Validation of the GROMOS force-field parameter set 45A3 against nuclear magnetic resonance data of hen egg lysozyme  

Energy Technology Data Exchange (ETDEWEB)

The quality of molecular dynamics (MD) simulations of proteins depends critically on the biomolecular force field that is used. Such force fields are defined by force-field parameter sets, which are generally determined and improved through calibration of properties of small molecules against experimental or theoretical data. By application to large molecules such as proteins, a new force-field parameter set can be validated. We report two 3.5 ns molecular dynamics simulations of hen egg white lysozyme in water applying the widely used GROMOS force-field parameter set 43A1 and a new set 45A3. The two MD ensembles are evaluated against NMR spectroscopic data NOE atom-atom distance bounds, {sup 3}J{sub NH{alpha}} and {sup 3}J{sub {alpha}}{sub {beta}} coupling constants, and {sup 1}5N relaxation data. It is shown that the two sets reproduce structural properties about equally well. The 45A3 ensemble fulfills the atom-atom distance bounds derived from NMR spectroscopy ...

2004-12-15

414

Wind energy mapping of coastal zones by synthetic aperture radar (SAR) for siting potential windmill locations  

Energy Technology Data Exchange (ETDEWEB)

The authors propose using synthetic aperture radar(SAR) for wind energy mapping of coastal zones. The SAR equipment is located on the European Space Agency ERS-1 and 2 and the RADARSAT satellites. Examples of wind energy maps and evaluations of their applications are given for the Norwegian west coast.

2000-07-01

415

Vehicle tracking systems  

Energy Technology Data Exchange (ETDEWEB)

Several systems have been developed to accomplish vehicle location. The systems consist of three types: Dead Reckoning, Satellite, and LORAN C. If the information is to be sent back to a central location, some type of radiocommunication system is needed. One can use the existing voice radio or add a radio system just for transmitting the data.

1987-01-01

416

TerF, the sixth identified replication arrest site in Escherichia coli, is located within the rcsC gene.  

UK PubMed Central (United Kingdom)

We report the existence of a sixth replication arrest site, TerF, that is located within the coding sequences of the rcsC gene, a negative regulator of capsule biosynthesis. The TerF site is oriented...Full Text Available

1992-12-01

417

Skills Training & Employment  

Wastenet

... Future Job Fund Scheme Goodwood Allotments Location: Goodwood Allotments Work undertaken by long-term unemployed young people under the Future Jobs Fund (FJF) transforms derelict allotments into a readily workable space for the local community. Western Park Location: Western Park, Hinckley Road, Leicester Groundwork conservation officers and Future Jobs Fund staff renew a Western Park spinney making it a better place for all. Bhavyesh ...

418

Optimal selection of capacitors for radial distribution systems using a genetic algorithm  

Energy Technology Data Exchange (ETDEWEB)

In this paper, a new design methodology for determining the size, location, type and number of capacitors to be placed on a radial distribution system is presented. The objective is to minimize the peak power losses and the energy losses in the distribution system considering the capacitor cost. A sensitivity analysis based method is used to select the candidate locations for the capacitors. A new optimization method using a Genetic Algorithm is proposed to determine the optimal selection of capacitors. Test results have been presented along with the discussion of the algorithm.

1994-08-01

419

Leak location in fluid filled cables using the PFT method  

Energy Technology Data Exchange (ETDEWEB)

A new method of pinpointing dielectric fluid leaks on pipe-type and self-contained cables using perfluorocarbon tracer (PFT) is presented. The method has successfully been used on the Con Edison transmission system to locate leaks of dielectric fluid on both types of cables. Application of the PFT technique does not require feeder deenergization and provides major advantages over the conventional method of freeze and pressure testing. Description of the method and results of field application are presented in the paper.

1999-01-01

420

Imaging findings of central nervous system neuroepithelial cysts  

Energy Technology Data Exchange (ETDEWEB)

Neuroepithelial cysts are rare and mostly asymptomatic cerebrospinal fluid (CSF)-like cysts. We describe herein the imaging findings in five patients with neuroepithelial cysts. Two cases of proven and three of presumed neuroepithelial cysts are presented. Three of five are located in the thalamus, a location which is not characteristic for neuroepithelial cysts. In the case of incidental finding of asymptomatic neuroepithelial cyst, clinical and radiological follow-up is indicated and surgical intervention is not necessarily warranted. (orig.) With 5 figs., 6 refs.

1998-05-01

421

First results of preoperative localisation of parathyroid glands adenomas by means of subtraction scintigraphy with technetium-99m and thallium-201  

International Nuclear Information System (INIS)

Eight patients with primary hyperparathyroidism were examined preoperative to locate the affected parathyroid glands. The localisation was done with technetium 99m and thallium 201. This new method seems to be of great value to locate preoperative the affected parathyroid glands. (R.B.).

422

Externally fired combined cycle for electric power generation from coal  

Energy Technology Data Exchange (ETDEWEB)

The externally fired combined cycle is emerging as an economically viable repowering options for old non-competitive coal fired steam plants. This paper describes the initial operation of a pilot plant located at Kennebunk, Maine and the initial work on the repowering of a 48MW coal fired steam plant located in Warren, PA.

1994-12-31

423

Case Studies  

Wastenet

... Future Job Fund Scheme Goodwood Allotments Location: Goodwood Allotments Work undertaken by long-term unemployed young people under the Future Jobs Fund (FJF) transforms derelict allotments into a readily workable space for the local community. New Parks Skegness Ride Location: New Parks Youth Centre Youths from the New Parks Club for Young People engage with sustainable transport and develop teamwork skills via a team bike ride. ...

424

USGS Arkansas Water Science Center  

Science.gov (United States)

number Fax (501) 228-3600 (501) 228-3601 Surface Water Data Information Requests Bill Baldwin (501) 228-3602 Surface Water General Information Jaysson Funkhouser (501) 228-3663...

2011-09-23

425

The BEACHES Study: health effects and exposures from non-point source microbial contaminants in subtropical recreational marine waters  

UK PubMed Central (United Kingdom)

Background Microbial water-quality indicators, in high concentrations in sewage, are used to determine whether water is safe for recreational purposes. Recently, the use of these indicators...Full Text Available

2010-10-01

426

Study on the separation characteristics of tritiated water vapor adsorption.  

Science.gov (United States)

In order to reduce the air concentration of (sup 3)H in the reactor buiIding of Wolsung Heavy Water Reactor, a computer code for estimation of adsorption behavior was programmed based on an equation derived for analysis of water vapor adsorption, and a ba...

1991-01-01

427

Rational protection of the quality of coastal waters by means of integrated, real-time management of the water environment; Proteccion racional de la calidad de las aguas costeras mediante la gestion integrada y en tiempo real del medio hidrico  

Energy Technology Data Exchange (ETDEWEB)

Before the implementation Water Framework directive, it was usual to forget that a good environment protection of the receiving waters needs a correct and coordinated operation of the subsystems of the water cycle, specially sewerage system, WWTP and receiving waters. This explains that most of the countries have focused their efforts in the treatment of dry weather flows forgetting the management of wet weather flows. Actually the idea that a sewerage system or a WWTP can not be planned or managed independently without considering the effects on the receiving waters is commonly accepted because not only each one of these systems must work correctly but also it is required a minimum impact in the receiving waters of the sewerage and WWTP overflows in dry and wet weather. All these links will affect the management strategy of the sewerage system (storm ...

2005-07-01

428

On the water-chemical regime in steam generators at NPP  

British Library Electronic Table of Contents (United Kingdom)

The effect of the water-chemical regime (WCR) on damage sustained by heating surfaces of steam generators at NPP is analyzed. It is indicated that phosphate treatment with minimal excesses of phosphates in the steamgenerator water is the most optimal method of managing the WCR regime of horizontal steam generators.

2006-01-01

429

Nodule and Leaf Nitrate Reductases and Nitrogen Fixation in Medicago sativa L. under Water Stress  

UK PubMed Central (United Kingdom)

The effect of water stress on patterns of nitrate reductase activity in the leaves and nodules and on nitrogen fixation were investigated in Medicago sativa L. plants watered 1 week...Full Text Available

1982-02-01

430

Monte Carlo modeling of 60Co HDR brachytherapy source in water and in different solid water phantom materials  

UK PubMed Central (United Kingdom)

The reference medium for brachytherapy dose measurements is water. Accuracy of dose measurements of brachytherapy sources is critically dependent on precise measurement of the source–detector...Full Text Available

2010-01-01

431

Modeling of soluble impurities distribution in the steam generator secondary water  

Energy Technology Data Exchange (ETDEWEB)

A model was developed to compute concentration of impurities in the WWER 440 steam generator (SG) secondary water along the tube bundle. Calculated values were verified by concentration values obtained from secondary water sample chemical analysis. (orig.). 2 refs.

1997-12-31

432

Measurement of the Water Potential of Stored Potato Tubers 1  

UK PubMed Central (United Kingdom)

A method of measuring the water potential of stored potato tubers (Solanum tuberosum L.) was needed to investigate the relationship of bacterial soft rot in tubers to water potential....Full Text Available

1985-11-01

433

Invasion and control of water hyacinth (Eichhornia crassipes) in China*  

UK PubMed Central (United Kingdom)

By the time of primary 21st century, water hyacinth had become a serious environmental problem in China. Water hyacinth contributes to the major part of ecological hazards from the invasion of foreign...Full Text Available

2006-08-01

434

In vivo Visualization of the Water-refilling Process in Xylem Vessels Using X-ray Micro-imaging  

UK PubMed Central (United Kingdom)

Background and AimsXylem vessels containing gases (embolized) must be refilled with water if they are to resume transport of water through the plant, so refilling is of great importance...Full Text Available

2008-03-01

435

Heat-transfer analysis of the plum brook reactor - NASA Technical ...  

Science.gov (United States)

average bulk water temper ature rise, OF bulk water temperature at elevation z, OF bulk water temperature in channels 0 and 1, O F film temperature, OF ...

436

Device for controlling water supply to nuclear reactor  

International Nuclear Information System (INIS)

Object: To smoothly control automatic water supply for realizing stable operation of a nuclear reactor by providing a flow rate limiting signal selection circuit and a preferential circuit in a water supply control device for a nuclear reactor wherein the speed of a recirculation pump may be changed in two-steps. Structure: Opening angle signals for a water supply regulating valve are controlled by a nuclear reactor water level signal, a vapor flow rate signal and a supplied water flow rate signal through an adder and an adjuster in response to a predetermined water level setting signal. When the water in the reactor is maintained at a predetermined level, a selection circuit receives a water pump condition signal for selecting one of the signals from a supplied water rate limiting signal generator ...

438

Bacterial indicators of risk of diarrhoeal disease from drinking-water in the Philippines.  

UK PubMed Central (United Kingdom)

Inadequate measures of water quality have been used in many studies of the health effects associated with water supplies in developing countries. The present 1-year epidemiological-microbiological study...Full Text Available

1991-01-01

439

Increasing concentrations of trihalomethanes (THMs) in a drinking water distribution network; Trihalometanos (THMs) en una red de distribucion de agua potable en alta  

Energy Technology Data Exchange (ETDEWEB)

THMs are disinfection by-products (DBPs) generated during water chlorination. Concentration of individual and total THMs, depends on treatment process and THMs precursors level. ATLL water utility has two DWTP (Llobregar and Ter) that produce and supply drinking water to Barcelona and regional area. This work studies the levels of THMs along the ATLL distribution system (450 km). Although, no differences were observed along water pipes system, changes of water resource and mix procedures were related. (Author) 12 refs.

1999-07-01

440

Fundamental R and D program on water chemistry of supercritical pressure water under radiation field  

International Nuclear Information System (INIS)

In a supercritical water-cooled reactor, property of water changes significantly around the critical point. It is expected that irradiation and change of water property will affect the chemistry and material corrosion. Deep understanding of interactions between supercritical water and materials under irradiation is important. However, comprehensive data on radiolysis, kinetics, corrosion and thermodynamics have not been obtained due to the severe experimental condition. To get such data by experiments and computer simulations, a national program funded by Ministry of Education, Culture, Sports, Science and Technology (MEXT) has been started since December 2002. (author)

2003-09-15

441

Evaluation of tritiated water retention capacity of fusion reactor concrete building  

Energy Technology Data Exchange (ETDEWEB)

In this paper the diffusion of tritiated water vapor into concrete walls is studied to evaluate tritiated water retention capacity of a fusion reactor concrete building. Using a model of the tritiated water diffusion determined form experimental results, depth profiles of tritiated water in concrete are calculated in the case of being exposed to air containing tritiated water vapor during the normal operational condition of a fusion reactor. A 0.5-m-thick concrete is sufficient for reactor hall walls from a viewpoint of the tritium containment.

1992-03-01

442

Evaluation of tritiated water retention capacity of fusion reactor concrete building  

International Nuclear Information System (INIS)

In this paper the diffusion of tritiated water vapor into concrete walls is studied to evaluate tritiated water retention capacity of a fusion reactor concrete building. Using a model of the tritiated water diffusion determined form experimental results, depth profiles of tritiated water in concrete are calculated in the case of being exposed to air containing tritiated water vapor during the normal operational condition of a fusion reactor. A 0.5-m-thick concrete is sufficient for reactor hall walls from a viewpoint of the tritium containment.

443

Water management studies in PEM fuel cells, part III: Dynamic breakthrough and intermittent drainage characteristics from GDLs with and without MPLs  

British Library Electronic Table of Contents (United Kingdom)

The transport of liquid water and gaseous reactants through a gas diffusion layer (GDL) is one of the most important water management issues in a proton exchange membrane fuel cell (PEMFC). In this work, the liquid water breakthrough dynamics, characterized by the capillary pressure and water saturation, across GDLs with and without a microporous layer (MPL) are studied in an ex-situ setup which closely simulates a real fuel cell configuration and operating conditions. The results reveal that recurrent breakthroughs are observed for all of the GDL samples tested, indicating the presence of an intermittent water drainage mechanism in the GDL. This is accounted for by the breakdown and redevelopment of the continuous water paths during water drainage as demonstrated by Haines jumps. For GDL ...

2010-01-01

444

Water You Engineering? An Activity to Develop Water-Quality Awareness  

Science.gov (United States)

Water is one of our most precious resources. However, for many in the United States, having fresh, safe drinking water is taken for granted, and due to this perceived lack of relevance, students may not fully appreciate the luxury of having safe running water--in the home. One approach to resolving water-quality issues in the United States may reside in providing education that presents accurate information in a meaningful way. Accordingly, this article describes a unit designed to emphasize the importance of water-quality testing and purification and to introduce students to local water-quality issues. The engineering-based module of this eighth-grade science activity is particularly important due to the design-build-test component. (Contains 5 figures.)

2009-04-01

445

Thermal- and radiation-induced interactions of water on U02 surfaces.  

Energy Technology Data Exchange (ETDEWEB)

Most plans for the disposition of surplus nuclear materials involve storage in sealed containers where the evolution of gases from reactions of adsorbed water could present both pressure and flammability hazards[l] . Despite efforts such as calcining the material to minimize the water content prior to packaging, both residual moisture and readsorbed water may be present in the final containers . Given the anticipated temperature excursions during transportation and storage, this water may thermally desorb, increasing the pressure, and/or thermally dissociate to produce H2 gas, increasing flammability hazards . In addition, the radiation from the nuclear material may induce radiolysis of the water with the likely products being water vapor, H2, 02 and H2O2. In order to better understand the relative importance of the thermal- and radiationinduced chemistry, we ...

2003-01-01

446

Radon concentration measurements at water reservoirs  

International Nuclear Information System (INIS)

Ground water is treated in the Czech Republic so that small water tanks are built above each water source to serve the primary ground water treatment; water so pretreated is then concentrated in large basins for subsequent treatment. Some water tanks where the first contact of the ground water with air takes place were selected as sites predisposed to radon accumulation. The examination was carried out near the town of Jihlava, where the bedrock contains slightly elevated radium concentrations. The average radon concentrations lay within the region of 2-4 kBq/m"3; the instantaneous values, however, exhibited appreciable periodical variations during the day. The relatively high radon concentrations will not pose a marked hazard for the personnel because the employees only reside at the sites in question for 10 to 15 minutes within 2 days, not ...

1998-09-09

448

Pipe Freeze Prevention for Passive Solar Water Heaters Using a Room-Air Natural Convection Loop: Preprint  

Energy Technology Data Exchange (ETDEWEB)

Conference paper regarding research in the use of freeze prevention for passive solar domestic water heating systems.

2006-05-01

449

Performance of single cylinder, direct injection diesel engine using water fuel emulsions  

Energy Technology Data Exchange (ETDEWEB)

A single cylinder diesel engine study of water-in-diesel emulsions was conducted to investigate the effect of water emulsification on the engine performance and gases exhaust temperature. Emulsified Diesel fuels of 0, 5, 10, 15 and 20 water/diesel ratios by volume were used in a single cylinder, direct injection diesel engine, operating at 1200-3300 rpm. The results indicate that the addition of water in the form of emulsion improves combustion efficiency. The engine torque, power and brake thermal efficiency increase as the water percentage in the emulsion increases. The average increase in the brake thermal efficiency for 20% water emulsion is approximately 3.5% over the use of diesel for the engine speed range studied. The proper brake specific fuel consumption and gases exhaust temperature decrease as the percentage of water in the ...

2004-03-01

450

Oreochromis lepidurus  

Science.gov (United States)

... Marine transport and oil disposal by boats and Matadi pose threats in the region. When the water ... Marine transport and oil disposal by boats and Matadi pose threats in the region. When the water ... ...

451

Oceanographic Processes and Marine Productivity in Waters Offshore ...  

Science.gov (United States)

Jun 16, 2011 ... Title: Chapter 21: Oceanographic Processes and Marine Productivity in Waters Offshore of Marbled Murrelet Breeding Habitat ...

452

Ocean Water: Density  

Science.gov (United States)

This site explains how temperature, pressure, and salinity work together to determine the density of ocean water. The three density layers of the ocean are described by means of text description and a graphic illustration.

453

NASA 11x:/,3 '/t.z- - NASA Technical Reports Server  

Science.gov (United States)

_! Packaging, Cleanlines_, Preparation j Handling ..... 35. 'I. 40. WATER ................ , ......... Sterile, High Purity, Ethylene Glycol-Water Solutions. Requirement For . ...

454

N. Mariana Islands Wildlife Action Plan  

Science.gov (United States)

... will utilize man-made habitats, including artificial wetlands, waste water ponds, water hazards on golf courses, and an abandoned ... ...

455

Mathematical modeling of a direct contact humidification?dehumidification desalination process  

British Library Electronic Table of Contents (United Kingdom)

Using air as a carrier gas is common in humidification?dehumidification desalination processes. A computer program was written using mass and energy balances for modeling the process behavior. The parameters considered in this work were inlet air and fresh water recycle temperatures, inlet air flow rate, saline water and fresh water recycle flow rates, and saline water to air flow ratio. Results of simulation showed that increasing inlet air and fresh water recycle flow rate increases fresh water production. It was also found that heating the inlet air to humidification column or cooling the inlet water to dehumidification column increases the production rate but increasing water to air flow ratio in a humidifier leads to a lower production rate. The predicted effects of the parameters on ...

2009-01-01

456

Managing a large outbreak of cryptosporidiosis: how to investigate and when to decide to lift a 'boil water' notice.  

Science.gov (United States)

The largest outbreak of cryptosporidiosis reported in the United Kingdom, involving 575 confirmed cases (of which 474 met an agreed case definition), occurred in the county of Devon during August and September of 1995. The descriptive epidemiology supports the hypothesis that the outbreak was associated with the consumption of cold tap water in the area served by a particular water treatment works. Cryptosporidium oocysts were detected in treated water samples at the time of the outbreak. Although the epidemiological analysis provided strong circumstantial evidence of a waterborne outbreak, the data were not recorded in a manner that made them admissible in criminal proceedings taken by the Drinking Water Inspectorate against the water company involved. The need to carry out an analytical study in conjunction with the identification and characterisation of the pathogen in the ...

2002-09-01

457

MTF ' MISSISSIPPI SOUND REMOTE SENSING STUDY I 19 SEPTEMBER 1972  

Science.gov (United States)

metric temperatures has been prepared showing the surface water temper- ... occasion, gray levels show different densities for similar water temper- ...

458

JPRS Report, Science & Technology, China: Energy  

Science.gov (United States)

... should give full con- As for the effects of the Three Gorges on the mouth of sideration to the rising water process and water temper- the river, the ...

1991-08-23

460

Ground-Water Data for the Suck Creek Area of Walden Ridge ...  

Science.gov (United States)

... Where Suck Creek enters the river, a formidable whirlpool and 2 Ground-water data for the Suck Creek area of Walden Ridge, Southern ...

2011-05-14

461

Fetal cardiotocography before and after water aerobics during pregnancy  

UK PubMed Central (United Kingdom)

ObjectiveTo evaluate the effect of moderate aerobic physical activity in water on fetal cardiotocography patterns in sedentary pregnant women.MethodIn...Full Text Available

462

Equipment for a central heating system with expansion tank, pressure control, water loss supply, de-aeration, recording and control; Apparaat t.b.v. C.V.-installatie met expansievat, drukregeling, waterverliessuppletie, ontluchting, registratie en controle  

Energy Technology Data Exchange (ETDEWEB)

The very low-pressure expansion tank of the title invention is connected to the water in the central heating installation via a connecting pipe with a pump and valves on one side, and on the other side the tank is connected via a connecting pipe with valve to the tap water mains, so that the supply of water can be regulated automatically. Within the expansion tank contact with the outside air is not possible because of an air/water separating floater. By means of recording and control (also remote) of the contents of the expansion tank, the installation pressure and the quantity of supplied water from the expansion tank and the tap water mains, failures and water damage are prevented. 4 figs.

1995-09-01

463

Ecology of Vibrio mimicus in aquatic environments.  

UK PubMed Central (United Kingdom)

An environmental study was done to examine the prevalence of Vibrio mimicus in some aquatic environments of Dhaka, Bangladesh, and of Okayama, Japan. Water samples from Dhaka environments and water...Full Text Available

1989-08-01

464

Density: Sea Water Mixing and Sinking - Aquarius - NASA  

Science.gov (United States)

density is slightly higher, its electrical conductivity is much higher, and it is slightly ... Sea water has characteristic properties (e.g. density) that are independent of ...

465

Assessing vineyard water status using the reflectance based Water Index  

British Library Electronic Table of Contents (United Kingdom)

In the Mediterranean arc, vines for wine production are mainly grown without the support of irrigation. Under such conditions, site variables affecting the extent and seasonal timing of water deficits are the dominant environmental constraints for grape production. Moreover, water availability and vine water status are the factors most comprehensively determining fruit composition and, thus, wine quality. Therefore, monitoring the extent of water stress in vines might be a valuable tool for the optimisation of grape yield and quality. The objective of this study was to evaluate the feasibility of using the reflectance based Water Index (WI) to estimate vine water status at the leaf and canopy levels. The study was conducted on Vitis vinifera cv. Chardonnay potted plants submitted to contra...

2010-01-01

466

Aqueous water-soluble soap lubricant concentrates and aqueous lubricants containing same  

Energy Technology Data Exchange (ETDEWEB)

The inclusion of neodecanoic acid in aqueous water-soluble soap lubricants reduces viscosity, and improves lubricity effectiveness.

1981-06-23

467

Anesthetic stimulation of insect water receptors.  

UK PubMed Central (United Kingdom)

Halothane, chloroform, and carbon tetrachloride, in the vapor and liquid phases, stimulate the water receptor of the blowfly Phormia regina. There are three successive phases of response to long-lasting...Full Text Available

1976-09-01

468

The numerical simulation on low-level radioactive waste water, low-temperature cooling water drained effect of implement from the Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

In this paper, we calculated the radioactive concentration distribution of radioactive waste water, the temperature distribution of drained cooling water and the effect of implement from the Daya Bay Nuclear Power Plant on nearby waters range, discussed and analysed some problems of computational results and computation with Alternating Direction Implicit Method (ADI). The contents of the article included: the establishment of two-dimension tidal current equation, radioactive waste water pollutant dispersion equation and cooling water heat convection diffusion equation, the numerical difference calculation model of tidal current field, concentration field as well as temperature field, effect impingement with ADI method, numerical calculation results. The result of research showed that: when the Daya Bay Nuclear Power Plant is on normal operation and after the low level radioactive ...

469

High quality water supply system; Joshitsusui kyokyu system  

Energy Technology Data Exchange (ETDEWEB)

This paper, firstly, introduces the background in developing a high quality water supply system, in which the drinking water system is isolated inside a building. Results of questionnaire on the high quality service water are illustrated. The results of questionnaire have revealed that the high quality service water is extremely interested. Then, are described the target quality of high quality water, the constitution of high quality water supply system, the treatment process, the measures to secure safety and sanitary, and the method of maintenance. The high quality water is produced through the activated charcoal absorption treatment, membrane treatment, ozonation, cooling, mineral addition, and disinfection of city water. Furthermore, application examples of this system adopted to a department store and a bachelor ...

1995-01-15

470

Environmental levels of tritium, 2  

International Nuclear Information System (INIS)

In an attempt to obtain basic data for evaluation of exposure doses in Niigata Prefecture, the concentrations of tritium in atmospheric water, precipitation, river water, and tap water were measured. Samples of atmospheric water, river water, and tap water were collected once for 2 weeks; and precipitation collected for one week was used as sample. The concentration of atmospheric tritium depended on the concentration of tritium in moisture and the content of water in atmosphere. Tritium levels were high in May, November and March, and low in September. Regarding tritium concentrations, there was a good correlation between atmospheric water and precipitation. Tritium concentrations in both of them varied from sample to sample. The concentrations of tritium in river and tap water tended to be high ...

471

Synchronized sampling improves fault location  

Energy Technology Data Exchange (ETDEWEB)

Transmission line faults must be located accurately to allow maintenance crews to arrive at the scene and repair the faulted section as soon as possible. Rugged terrain and geographical layout cause some sections of power transmission lines to be difficult to reach. In the past, a variety of fault location algorithms were introduced as either an add-on feature in protective relays or stand-alone implementation in fault locators. In both cases, the measurements of current and voltages were taken at one terminal of a transmission line only. Under such conditions, it may become difficult to determine the fault location accurately, since data from other transmission line ends are required for more precise computations. In the absence of data from the other end, existing algorithms have accuracy problems under several circumstances, such as varying switching and loading conditions, fault infeed from the ...

1995-04-01

472

Grid-Search Location Methods for Ground-Truth Collection From Local and Regional Seismic Networks  

Energy Technology Data Exchange (ETDEWEB)

This project investigated new techniques for improving seismic event locations derived from regional and local networks. The technqiues include a new approach to empirical travel-time calibration that simultaneously fits data from multiple stations and events, using a generalization of the kriging method, and predicts travel-time corrections for arbitrary event-station paths. We combined this calibration approach with grid-search event location to produce a prototype new multiple-event location method that allows the use of spatially well-distributed events and takes into account correlations between the travel-time corrections from proximate event-station paths. Preliminary tests with a high quality data set from Nevada Test Site explosions indicated that our new calibration/location method offers improvement over the conventional multiple-event location methods now in common use, ...

2005-05-13

473

Global positioning automatic vehicle location system  

Energy Technology Data Exchange (ETDEWEB)

Los Alamos National Laboratory (LANL) is a unique facility covering over 43 square miles. The Emergency Management and Response Office (EM&R) is required to respond, provide Incident Command (IC), and coordination for all Laboratory emergencies. This requires IC`s and support staff to respond to the actual scene of the incident. Since the IC is under numerous constraints and stress, the office wanted the capability of locating the EM&R vehicles on an electronic map. An automated vehicle location (AVL) system was required for the additional safety of the emergency response personal. The requirements for the AVL system include total automatic tracking and low cost. After careful consideration, it was determined that the most efficient and cost effective system would be based on packet radio technology as the transmission media. The location is determined by the Department of Defense Global Positioning System (GPS). ...

1997-03-01

474

Magnetobiostratigraphy of the continental Paleocene upper Coalspur and Paskapoo formations near Hinton, Alberta  

Energy Technology Data Exchange (ETDEWEB)

A chronology for Paleocene strata of the Hinton area of west-central Alberta was developed from the integration of a magnetostratigraphic and palynostratigraphic study of the upper Coalspur and middle to upper Paskapoo strata in the Coal Valley to Obed Mountain area. The study resulted in the compilation of a complete section of 1100 m of strata with a maximum sediment accumulation rate of 250 m/m.y. Four new informal biostratigraphic units were used to highlight stratigraphically useful bioevents not previously recognized in existing zonations. These strata range in age from magnetochron 29r to 24r and palynozones Wodehouseia spinata Zone, Aquilapollenites reticulatus Subzone through the Pistillipollenite mcgregorii Zone. The 3 intervals with the most rapid changes in the palynoflora were the earliest Paleocene; the transition from the early to middle Paleocene; and in the late Paleocene. Each coincides with critical times in basin development, notably the initiation of regionally ...

2008-06-15

475

Combined photochemical-biological processes for treatment of unleaded gasoline oxygenates : MTBE, ETBE and TAME  

Energy Technology Data Exchange (ETDEWEB)

A study was conducted to determine the feasibility and the opportunity of photochemical pretreatment on the biodegradation and detoxification of Methyl Tert Butyl Ether (MTBE), Ethyl Tert Butyl Ether (ETBE) and Tert Amyl Methyl Ether (TAME), the most common oxygenates used as octane enhancers in unleaded gasoline. The production, storage, uses and disposal of oxygenates result in an unknown amount of groundwater pollution. Because of their high solubility, MTBE, ETBE and TAME are detected in large portions in saturated zones of aquifers. The biodegradation of these oxygenates is difficult and slow, and information regarding their biodegradability is scarce. Photo-decomposition of oxidants under appropriate UV radiation has been shown to be very effective because the hydroxyl radicals produced possess high oxidation potential. In this study, the H{sub 2}O{sub 2}/UV process was used to generate hydroxyl radicals. Maximal oxygenates transformation was obtained in a ...

1998-10-01

476

Combined photochemical-biological processes for treatment of unleaded gasoline oxygenates : MTBE, ETBE and TAME  

International Nuclear Information System (INIS)

A study was conducted to determine the feasibility and the opportunity of photochemical pretreatment on the biodegradation and detoxification of Methyl Tert Butyl Ether (MTBE), Ethyl Tert Butyl Ether (ETBE) and Tert Amyl Methyl Ether (TAME), the most common oxygenates used as octane enhancers in unleaded gasoline. The production, storage, uses and disposal of oxygenates result in an unknown amount of groundwater pollution. Because of their high solubility, MTBE, ETBE and TAME are detected in large portions in saturated zones of aquifers. The biodegradation of these oxygenates is difficult and slow, and information regarding their biodegradability is scarce. Photo-decomposition of oxidants under appropriate UV radiation has been shown to be very effective because the hydroxyl radicals produced possess high oxidation potential. In this study, the H_2O_2/UV process was used to generate hydroxyl radicals. Maximal oxygenates transformation was obtained in a few minutes. ...

1998-10-01

478

Survey of state water quality standards for wetlands  

Energy Technology Data Exchange (ETDEWEB)

This document summarizes the degree to which State water quality standards include wetlands in their definitions of State waters. The detailed review of other elements of standards, such as uses, criteria and antidegradation, is beyond the scope of this review. The purpose of this review is to provide a baseline of information for the development of EPA guidance and policies related to water quality standards for wetlands.

1989-08-17

480

Sinus Surgery  

Medline Plus

... know if the drainage becomes very clear, like tap water. This may be the first indication that there ...

483

High resolution neutron imaging of water in the polymer electrolyte fuel cell membrane  

Energy Technology Data Exchange (ETDEWEB)

Water transport in the ionomeric membrane, typically Nafion{reg_sign}, has profound influence on the performance of the polymer electrolyte fuel cell, in terms of internal resistance and overall water balance. In this work, high resolution neutron imaging of the Nafion{reg_sign} membrane is presented in order to measure water content and through-plane gradients in situ under disparate temperature and humidification conditions.

2009-01-01

484

General corrosion of ALLOY 800 in high temperature water and its prevention  

Energy Technology Data Exchange (ETDEWEB)

General corrosion behavior of ALLOY 800 in high temperature water was studied in relation to its surface film structure. The surface film formed in water was found to decrease the corrosion rate of ALLOY 800. This film is composed of Ni ferrite, and can be obtained by oxidation in air or steam. Based on these results, air or steam oxidation treatment to inhibit Ni and Co release of ALLOY 800 into high temperature water is proposed. (author).

1989-10-01

485

General corrosion of ALLOY 800 in high temperature water and its prevention  

International Nuclear Information System (INIS)

General corrosion behavior of ALLOY 800 in high temperature water was studied in relation to its surface film structure. The surface film formed in water was found to decrease the corrosion rate of ALLOY 800. This film is composed of Ni ferrite, and can be obtained by oxidation in air or steam. Based on these results, air or steam oxidation treatment to inhibit Ni and Co release of ALLOY 800 into high temperature water is proposed. (author).

491

Conference on climate and water. Volume 2  

Energy Technology Data Exchange (ETDEWEB)

This book contains the Proceedings of the Conference on Climate and Water under the following groupings: Impacts of climatic variability and change-resulting from the changes in hydrological variables; Aquatic environment; Terrestrial environment; Coastal zones and navigation; Urban and industrial water supply and drainage; Energy production; Intropogenic changes of climate and water management problems; Flood potential; Irrigation and land drainage.

1989-12-31

492

China's water crisis  

Energy Technology Data Exchange (ETDEWEB)

After the devastating natural disasters that have hit China recently, another crisis is looming, Drought, pollution and heavy usage in the fast-developing megacities have resulted in a shortage of water. A huge construction effort is underway to divert water from the south to the north. But experts warn that it will not solve China's structural water problems.

2008-07-15

496

Aerosols Equipment in Manitoba on Environmental Expert  

Wastenet

... Hale, Markku Kulmala, 373.43 EUR; 225.00 USD; 276.00 GBP... Aerosol Chemical Processes in the Environment Spurny, Kvetoslav R., $164,95, 䀈... More Journals » MAGAZINES & JOURNALS Water Science & Technology: Water Supply Water Science and Technology: Water Supply is p... ...