WorldWideScience
2

Economic analysis of effluent limitation guidelines and standards for the centralized waste treatment industry  

Science.gov (United States)

This report estimates the economic and financial effects and the benefits of compliance with the proposed effluent limitations guidelines and standards for the Centralized Waste Treatment (CWT) industry. The Environmental Protection Agency (EPA) has measured these impacts in terms of changes in the profitability of waste treatment operations at CWT facilities, changes in market prices to CWT services, and changes in the quantities of waste management at CWT facilities in six geographic regions. EPA has also examined the impacts on companies owning CWT facilities (including impacts on small entities), on communities in which CWT facilities are located, and on environmental justice. EPA examined the benefits to society of the CWT effluent limitations guidelines and standards by examining cancer and non-cancer health effects of the regulation, recreational benefits, and cost savings to publicly owned ...

1998-12-01

3

Environmental implications of coal gasification/liquefaction technologies in Canada  

Energy Technology Data Exchange (ETDEWEB)

This report reviews coal conversion processes which may be introduced in Canada within the next decade if interest in alternate energy technologies continues. A detailed review was conducted on coal liquefaction and gasification projects worldwide including information on individual proprietors, process technologies used, their present status and available environmental data. Further assessment of emissions and wastes emanating from commercial-scale plants was used to determine significant or potentially significant wastestreams connected to the various technologies, particularly wastewater discharges. Emphasis was placed on those technologies that are close to commercialization in Canada, i.e. SASOL II-type liquefaction facility at Hat Creek. Available information on wastewater treatment/reuse is also included in this report.

1983-01-01

4

Effect of Wastewater Treatment Plant Effluent on Microbial Function and Community Structure in the Sediment of a Freshwater Stream with Variable Seasonal Flow?  

UK PubMed Central (United Kingdom)

We investigated the effects of wastewater treatment plant (WWTP) discharge on the ecology of bacterial communities in the sediment of a small, low-gradient stream in South Australia. The quantification...Full Text Available

2008-05-01

5

The Oak Ridge Y-12 Plant biological monitoring and abatement program for East Fork Poplar Creek  

Energy Technology Data Exchange (ETDEWEB)

In May 1985, a National Pollutant Discharge Elimination System permit was issued for the Oak Ridge Y-12 Plant, a nuclear weapons components production facility located in Oak Ridge, Tennessee, and operated by Martin Marietta Energy Systems, Inc., for the US Department of Energy. As a condition of the permit, a Biological Monitoring and Abatement Program (BMAP) was developed to demonstrate that the effluent limitations established for the Oak Ridge Y-12 Plant protect the classified uses of the receiving stream (East Fork Poplar Creek), in particular, the growth and propagation of fish and aquatic life, as designated by the Tennessee Department of Health and Environment. A second purpose for the BMAP is to document the ecological effects resulting from implementation of a water pollution control program that will include construction of nine new wastewater treatment facilities over the next 4 years. ...

1989-10-01

6

TOXCHEM: Predicting the fate of toxics in wastewater treatment plants  

Energy Technology Data Exchange (ETDEWEB)

TOXCHEM is a microcomputer based modelling system for predicting the fate of toxic contaminants in wastewater treatment plants. The package evaluates concentrations of toxics in final effluent and waste sludge, and mass air emissions from municipal or industrial activated sludge wastewater treatment plants. Maximum allowable influent concentrations of toxics required to meet effluent discharge or air emission limits can also be estimated. The package contains a read-only database with treatability parameters for over 100 contaminants, including organic compounds and metals. If effluent or sludge quality limits have been specified, treatment plant owners and operators can use the package to estimate the permissable discharge limits for dischargers to their collection system. A hypothetical example is provided of application of the software to a planning problem involving the start up ...

1991-12-01

7

Maryland mill will recycle wastepaper, reclaim water  

Energy Technology Data Exchange (ETDEWEB)

A $200 million paper mill being built in Hagerstown, Md., is expected to produce 150,000 bone-dry short tons per year of de-inked, market-grade pulp for writing and printing paper. The 1st Urban Fibers facility, the largest capital project in Hagerstown's history, is slated for completion in the spring. Landegger Recycled Fiber Corp. will operate and maintain the 200,000-square-foot recycling mill and 60,000-square-foot water reclamation plant. The wastepaper recycling mill plans to minimize waste and pollution by: reclaiming 635 tons per day of 100 percent post-consumer mixed office waste from the solid waste stream; saving more than 16 million cubic feet of landfill area per year; conserving the fiber equivalent of 6,700 trees per day; using no chlorine; saving about 2,000 gallons of water and 4,000 kilowatt hours of electricity per ton of throughput, compared to virgin fiber mills; reusing treated wastewater, reducing effluent ...

1995-02-01

8

Liquid waste evaporator operating experience  

Energy Technology Data Exchange (ETDEWEB)

Atomic Energy of Canada Limited (AECL) operates the Waste Treatment Centre (WTC) to treat and immobilize some of the low- level radioactive waste (LLRW) streams at the Chalk River Laboratories (CRL). The WTC at treats low- level radioactive liquid waste by removing the contaminants from the wastewater, concentrating them, and immobilizing them. The fundamental design concept for the WTC is to process the waste streams using forced circulation type liquid waste evaporation (LWE), to solidify the concentrates using thin film evaporator and to discharge the purified effluent into the Ottawa River following verification monitoring. The solidified product drums are stored in existing storage facilities in the CRL. The LWE was installed in the WTC to treat the LLRW. After about four (4) years of design, construction and cold commissioning, the active commissioning of the evaporator process using radioactive waste streams ...

2006-07-01

9

Liquid waste evaporator operating experience  

International Nuclear Information System (INIS)

Atomic Energy of Canada Limited (AECL) operates the Waste Treatment Centre (WTC) to treat and immobilize some of the low- level radioactive waste (LLRW) streams at the Chalk River Laboratories (CRL). The WTC at treats low- level radioactive liquid waste by removing the contaminants from the wastewater, concentrating them, and immobilizing them. The fundamental design concept for the WTC is to process the waste streams using forced circulation type liquid waste evaporation (LWE), to solidify the concentrates using thin film evaporator and to discharge the purified effluent into the Ottawa River following verification monitoring. The solidified product drums are stored in existing storage facilities in the CRL. The LWE was installed in the WTC to treat the LLRW. After about four (4) years of design, construction and cold commissioning, the active commissioning of the evaporator process using radioactive waste streams ...

2005-05-08

10

Toxicity of N-substituted aromatics to acetoclastic methanogenic activity in granular sludge  

Energy Technology Data Exchange (ETDEWEB)

N-substituted aromatics are important priority pollutants entering the environment primarily through anthropogenic activities associated associated with the industrial production of dyes, explosives, pestides, and pharmaceuticals. Anaerobic treatment of wastewaters discharged by these industries could potentially be problematical as a result of the high toxicity of N-substituted aromatics. The objective of this study was to examine the structure-toxicity relationship of N-substituted aromatic compounds to acetoclastic methanogenic bacteria. The toxicity was assayed to serum flasks by measuring methane production in granular sludge. Unacclimated cultures were used to minimize the biotransformation of the toxic organic chemicals during the test. The nature and the degree of the aromatic substitution were observed to have a profound effect on the toxicity of the test compound. Nitroaromatic compounds were, on the average, over 500-fold more toxic ...

1995-11-01

11

Flue gas desulfurization wastewater treatment primer  

Science.gov (United States)

Purge water from a typical wet flue gas desulfurization system contains myriad chemical constituents and heavy metals whose mixture is determined by the fuel source and combustion products as well as the stack gas treatment process. A well-designed water treatment system can tolerate upstream fuel and sorbent arranged in just the right order to produce wastewater acceptable for discharge. This article presents state-of-the-art technologies for treating the waste water that is generated by wet FGD systems. 11 figs., 3 tabs.

2009-03-15

12

Fate of volatile organic compounds in wastewater collection systems, volumes IV-VIII  

Energy Technology Data Exchange (ETDEWEB)

This publication compiles five documents on volatile organic compounds (VOCs) in wastewater collection systems. The first is a thesis describing experiments conducted to obtain parameters for determining the significance of biodegradation relative to volatilization as a VOC fate mechanism in sewers. The second is a compilation of three papers from the 1992-94 conferences of the Air & Waste Management Association (AWMA). The papers concern VOC emissions at sewer drop structures and an estimation method for determining VOC emissions from industrial sewers. The third is a compilation of two papers from the AWMA 1992 and 1994 conferences, covering the formation of chloroform from household sources. The fourth is a thesis on post-discharge formation of chloroform in untreated municipal wastewater. The final document is a report detailing the derivation of fate mechanism models in the TOXCHEM model.

1994-12-31

13

Use of sanitary sewers as wastewater pre-treatment systems  

Energy Technology Data Exchange (ETDEWEB)

As wastewater travels through a sewer system it undergoes changes in composition. The changes in composition may be caused by chemical, physical and/or biological processes. At present engineers do not take into consideration the impacts of these processes on the wastewater quality when designing wastewater treatment systems. However, the impact of these processes on the chemical oxygen demand, biochemical oxygen demand, nitrogen and phosphorus content of the wastewater can be significant. In the case of the biological processes, microorganisms present in the water as it travels through the sewer system are similar to those found in an activated sludge process. Given that the microorganism population and the hydraulic retention time often resembles that of an activated sludge process, it would seem only reasonable to look further into the possibility of using sewers as wastewater ...

1998-12-31

14

Shooting from the HIP: Hyperion's efforts to clean Santa Monica Bay. [Hyperion Improvement Program (HIP)  

Energy Technology Data Exchange (ETDEWEB)

The Outstanding Achievement Award in Water Pollution Control' is intended to recognize the water pollution control program that best demonstrates achieving significant, lasting, and measurable excellence in water-quality improvement in preventing water-quality degradation in a region, basin, or water body. This article is about the 1991 Award. This year, WPCF honored Los Angeles Hyperion Treatment Plant with a citation of outstanding achievement. To qualify for this honor, Hyperion has remarkably improved the quality of wastewater discharged to Santa Monica Bay since 1985. Capital programs developed by Los Angeles to achieve this rapid improvement, coined the Hyperion Improvement Program (HIP), reflect the city's commitment to protect the valuable resource of Santa Monica Bay. The HIP was conceived in 1986 to cease sludge ocean disposal by the end of 1987 and expedite effluent quality improvement before 1991, when the full ...

1991-11-01

15

Science and common sense in Port Valdez, Alaska  

Energy Technology Data Exchange (ETDEWEB)

Valdez, Alaska achieved worldwide attention with the Exxon Valdez oil spill. This exacerbated an already polarized situation (industry, government, citizens, environmental groups) regarding the Valdez Terminal of the Trans Alaska Pipeline System. Other than spills, the major focus of environmental concern was and remains the Terminal`s Ballast Water Treatment Plant (BWTP) which discharges into Port Valdez. The previous NPDES wastewater discharge permits for this facility have been contentious for almost the entire period of pipeline operation. The draft NPDES permit is scheduled to be proposed for reissuance this year. However, a significant change has been initiated which so far is resulting in cooperation rather than confrontation between the various primary stakeholders. This presentation will explain how this change was initiated, how it is being maintained, and how what is happening could be a ...

1995-12-31

16

Occurrence of fecal indicator bacteria in surface waters and the subsurface aquifer in Key Largo, Florida.  

UK PubMed Central (United Kingdom)

Sewage waste disposal facilities in the Florida Keys include septic tanks and individual package plants in place of municipal collection facilities in most locations. In Key Largo, both facilities discharge...Full Text Available

1995-06-01

17

Characterization and uncertainty analysis of VOCs emissions from industrial wastewater treatment plants  

British Library Electronic Table of Contents (United Kingdom)

Air toxics from the industrial wastewater treatment plants (IWTPs) impose serious health concerns on its surrounding residential neighborhoods. To address such health concerns, one of the key challenges is to quantify the air emissions from the IWTPs. The objective here is to characterize the air emissions from the IWTPs and quantify its associated uncertainty. An IWTP receiving the wastewaters from an airplane maintenance facility is used for illustration with focus on the quantification of air emissions for benzyl alcohol, phenol, methylene chloride, 2-butanone, and acetone. Two general fate models, i.e., WATER9 and TOXCHEM+V3.0 were used to model the IWTP and quantify the air emissions. Monte Carlo and Bootstrap simulation were used for uncertainty analysis. On average, air emissions fr...

2010-01-01

18

Economic Impact Analysis of Proposed Effluent Limitations Guidelines and Standards for the Pesticide Manufacturing Industry.  

Science.gov (United States)

The report details the economic impact of two alternative regulatory options; a Treated Discharge Option and a Zero Discharge Option on facilities that would have to comply with the regulations as part of the reproposal of effluent limitations and standar...

1992-01-01

19

Air pollutants emissions from waste treatment and disposal facilities.  

Science.gov (United States)

This study examined the atmospheric pollution created by some waste treatment and disposal facilities in the State of Kuwait. Air monitoring was conducted in a municipal wastewater treatment plant, an industrial wastewater treatment plant established in a petroleum refinery, and at a landfill site used for disposal of solid wastes. Such plants were selected as models for waste treatment and disposal facilities in the Arabian Gulf region and elsewhere. Air measurements were made over a period of 6 months and included levels of gaseous emissions as well as concentrations of volatile organic compounds (VOCs). Samples of gas and bioaerosols were collected from ambient air surrounding the treatment facilities. The results obtained from this study have indicated the presence of VOCs and other gaseous pollutants such as methane, ammonia, and hydrogen sulphide in air surrounding the waste ...

2006-01-01

20

A management scheme for reducing pollution at air discharge facility in advance  

Energy Technology Data Exchange (ETDEWEB)

The developed countries are implementing a policy minimizing damage from environmental pollution by reducing discharge in advance as well as the aftermath of a pollutant. The typical example is to use BAT (Best Available Technology). This is to prevent environmental damage by reducing the discharge of pollutants with available technology and to secure environmental margin to enable industrial activities of future generation. Therefore, the feasibility of introducing BAT requirement system was reviewed by considering foreign examples and Korean situation. 38 refs., 8 figs., 69 tabs.

1998-12-01

21

Waste characterization study for the Kemp's Ridley sea turtle. Technical memo  

Energy Technology Data Exchange (ETDEWEB)

The Kemp's Ridley sea turtle, Lepidochelys kempi, is an endangered species. The National Marine Fisheries Service's Head Start program is part of an international operation to save the turtles from extinction. Under the Head Start program, eggs from the Ridley's only known wild nesting beach at Rancho Nuevo in Mexico are transported to Padre Island on the Texas coast to be hatched. The head start enables the turtles to develop a survival advantage. The principal objective was to develop baseline waste-characterization data required to design a waste-water treatment scheme for the Galveston Head Start facility. As a secondary objective, preliminary testing of some filtration components was undertaken to determine which units were most appropriate for inclusion in a wastewater treatment scheme.

1988-02-01

22

Changes in aerobic digester performance with the use of methanol for biological nutrient removal in a full-scale sequencing batch reactor  

Energy Technology Data Exchange (ETDEWEB)

Increasingly, governments enact more stringent regulations governing nitrogen and phosphorus in the discharge effluent of wastewater treatment plants. Scientists know that nitrogen and phosphorus accelerates the eutrophication of lakes and reservoirs and stimulates algal growth. Ammonia has proven to be toxic to aquatic life forms, including fish. Engineers favour Biological Nutrient Removal (BNR) over chemical addition to wastewater treatment. Sequencing Batch Reactors (SBRs), a type of bioreactor requiring less land, provide the anaerobic, anoxic, and aerobic zones necessary for BNR. Methanol was used as an effective external source of carbon for denitrification but lacked research. The authors remedied this situation and some of the results were available. They indicated that the addition of methanol in the SBR increased solids production in the SBR, leading to increased sludge wasting to the aerobic digester. All ...

2000-07-01

23

Problems and solutions of the IFSMTF power and switch system  

Energy Technology Data Exchange (ETDEWEB)

Solutions have been found for the problems encountered with the coil power and switching systems of the International Fusion Superconducting Magnet Test Facility (IFSMTF). The coil power system provides the filtered dc sources (+- 12 V dc; 25,000 A) for charging and discharging the coils of the IFSMTF experiment. The switching system provides the means of transferring the coil current into a dump resistor when a rapid discharge of a coil is required due to a coil failure (quench) or other system abnormalities.

1985-01-01

24

Development Document for Proposed Effluent Limitations Guidelines and Standards for the Porcelain Enameling Point Source Category.  

Science.gov (United States)

This document is a technical background document for proposed regulations to limit effluent discharges to waters of the United States and introductions of pollutants into publicly owned treatment works from facilities engaged in porcelain enameling. The p...

1981-01-01

27

Experiences of simulated tracer dispersal studies using effluent discharges at Tarapur aquatic environment  

International Nuclear Information System (INIS)

The nuclear complex in Tarapur, Maharashtra is a multi facility nuclear site comprising of power reactors and research facilities. Each facility has independent liquid effluent discharge line to Arabian Sea. Experimental studies were conducted to evaluate dilution factors in the aquatic environment using liquid effluent releases as tracer from one of the facilities. 3H and 137Cs radioisotopes present in the routine releases were used as simulated tracer nuclides. The dilution factors(D.F) observed for tritium were in the range of 20-20000 in a distance range of 10 m to 1500 m respectively and for 137Cs the D.F. were in the range of 50 to 900 over a distance range of 10-200 m. The paper describes the analytical methodology and sampling scenarios and the results of dilution factors obtained for Tarapur aquatic environment. (author)

2007-06-05

28

The Bullhouse Project - Phase 2  

Energy Technology Data Exchange (ETDEWEB)

The operation of the Bullhouse Minewater System, used to treat iron-rich minewaters discharged from long-abandoned coal mines, was studied to minimise pollution of the Upper Don river in the UK. Tests were carried out to determine optimal operating conditions. Ochre flocculation with polyacrylamide was efficient in batch tests as the ochre self-flocculated and sedimented in the lagoon without the need for chemical enhancement. The rate of accretion of the pipework in the system was modified by partial dewatering, reshaping and hardening of the deposits during ageing. Samples of ochre recovered from the drying beds and sump deposits were converted to ferric sulphate coagulant by dissolution with sulphuric acid and used with a polyelectrolyte to successfully purify reservoir water and pretreat wastewater. There was considerable local interest in the scheme with educational opportunities for schools and colleges.

2000-12-01

29

Temperature effects on wastewater nitrate removal in laboratory-scale constructed wetlands  

Energy Technology Data Exchange (ETDEWEB)

Constructed wetlands may be used for removal of high nutrient loads in greenhouse wastewater prior to discharge into the environment. Temperature affects both the physical and biological activities in wetland systems. Since nitrification and denitrification are temperature-dependent processes, effluent nitrate concentrations will fluctuate due to changes in air and wetland temperature. In a cold climate, constructed wetlands can function in a temperature-controlled, greenhouse environment year-round. This work evaluates four temperature treatments on nitrate removal rates in five planted and five unplanted laboratory-scale wetlands. Wetlands were supplied with a nutrient solution similar to the fertigation runoff solution (100 PPM nitrate-N) used in greenhouse crop production. A first-order kinetic model was used to describe experimental nitrate depletion data and to predict nitrate removal rate constants (k) in the wetlands planted with Iris ...

1999-02-01

30

Offshore: North Sea facility gets the CETCO solution  

British Library Electronic Table of Contents (United Kingdom)

CETCO Oilfield Services, suppliers of environmental systems, have undertaken a project to treat contaminated water returns on a Floating, Production, Storage and Offloading (FPSO) facility in the North Sea. The solution sees fluids treated during oil well clean-up operations, reducing the potential for overboard oil discharges, and resulting production upsets.

2006-01-01

31

Comprenhensive Program of Engineering and Geologic Surveys for Designing and Constructing Radioactive Waste Storage Facilities in Hard Rock Massifs  

Energy Technology Data Exchange (ETDEWEB)

Geological, geophysical, and engineering-geological research conducted at the 'Yeniseisky' site obtained data on climatic, geomorphologic, geological conditions, structure and properties of composing rock, and conditions of underground water recharge and discharge. These results provide sufficient information to make an estimate of the suitability of locating a radioactive waste (R W) underground isolation facility at the Nizhnekansky granitoid massif

2002-12-27

32

Development document for proposed effluent limitations guidelines and standards for the centralized waste treatment industry. Volumes 1 and 2  

Energy Technology Data Exchange (ETDEWEB)

This document includes the following topics: Background; Data Collection; Scope/Applicability of the Proposed Regulation; Description of the Industry; Industry Subcategorization; Pollutants of Concern for the Centralized Waste Treatment Industry; Pollutants Selected for Regulation; Wastewater Treatment Technologies; Regulatory Options Considered and Selected for Basis of Regulation; Long-Term Averages, Variability Factors, and Limitations and Standards; Cost of Treatment Technologies; Pollutant Loading and Removal Estimates; Non-Water Quality Impacts; Implementation; Analytical Methods and Baseline Values; List of Definitions; List of Acronyms; Appendix A--Pollutant Groups; Appendix B--Listing of Characerization Data From Non-Hazardous Oils Facilities; Appendix C--Listing of Daily Influent and Effluent Measuements; Appendix D--Facility-Specific Compliance Costs; Appendix E--Attachements to Chapter 10; and Appendix ...

1998-12-01

33

Aquatic macroinvertebrates and water quality in Sandia Canyon  

International Nuclear Information System (INIS)

In 1990, field studies of water quality and stream macroinvertebrate communities were initiated in Sandia Canyon at Los Alamos National Laboratory. The studies were designed to establish baseline data and to determine the effects of routine discharges of industrial and sanitary waste. Water quality measurements were taken and aquatic macroinvertebrates sampled at three permanent stations within the canyon. Two of the three sample stations are located where the stream regularly receives industrial and sanitary waste effluents. These stations exhibited a low diversity of macroinvertebrates and slightly degraded water quality. The last sample station, located approximately 0.4 km (0.25 mi) downstream from the nearest wastewater outfall, appears to be in a zone of recovery where water quality parameters more closely resemble those found in natural streams in the Los Alamos area. A large increase in macroinvertebrate diversity was also observed at ...

2005-09-01

34

Radionuclide X-ray fluorescence determination of Mn, Fe, Cu, Zn and Pb in wastewaters and sludges from wastewater treatment plants in Bratislava (SR)  

International Nuclear Information System (INIS)

Radiometric X-ray fluorescence analysis was used for the determination of Mn, Fe, Cu, Zn and Pb in wastewater and sludges from three wastewater treatment plants in Bratislava (SR). Metals were determined in wastewaters after preconcentration by 8-hydroxyquinoline and in sludges by drying and pressing to pellets. "2"3"8Pu and "1"0"9Cd was used for excitation of fluorescence radiation. (author).

1997-01-01

35

Vacuum arc ignition by penning discharge in a strong magnetic field  

Energy Technology Data Exchange (ETDEWEB)

Vacuum arc with cathode spots on the cold electrode is widely used as a plasma generator in a such kind of devices like metal ion sources, plasma cathode electron guns, thing films deposition facilities and others. Most vacuum arc devices utilize a high voltage discharge across an insulator surface to provide a trigger plasma which in turn initiates the main arc discharge. Operation of vacuum arc in a repetitively pulsed mode required a stable triggering system for the long time. But with a discharge across the insulators the number of stable pulses is limited by 100,000 or little bit more. The better method for vacuum arc ignition is low pressure discharge. As shown in this paper it is possible to increase the lifetime of the ignition system in 10 times at least, but negative characteristic of this system is a relatively high pressure (about 0.1 mtorr). In some kinds of vacuum arc ...

1995-12-31

36

Electrochemical properties of Cu{sub 2}O/Cu composite particles prepared by a novel and facile method  

Energy Technology Data Exchange (ETDEWEB)

In this study, Cu{sub 2}O/Cu composite particles were synthesized using an innovative chemical reduction method without any template and surfactant. X-ray diffraction (XRD) analysis revealed that the product mainly consisted of Cu{sub 2}O phase coexisting with a Cu phase. FE-SEM images showed that the octahedral shaped particles were Cu{sub 2}O. The electrochemical performance of the Cu{sub 2}O/Cu particles was investigated with regards to the working electrode material in alkaline solution. The particles had a maximum discharge capacity of 222.9 mAh/g at a discharge current density of 60 mA/g and a high value of 109.1 mAh/g after 50 charge-discharge cycles. Cyclic voltammetry revealed that the reaction between Cu{sub 2}O and Cu is the major electrochemical reaction during the charging and discharging process. Electrochemical impedance spectroscopy revealed that the formation of Cu{sub 2}O on the ...

2010-07-01

37

Turbulence in the positive column of a glow discharge  

CERN Document Server

Turbulence in the positive column of a glow discharge

1969-01-01

38

A study on the distribution of "1"3"7Cs in coastal waters of Tarapur from different nuclear facilities  

International Nuclear Information System (INIS)

A study on the distribution of "1"3"7Cs in coastal waters up to a distance of 15 km was undertaken for a decade (1995-2004) and observed that the activity has reduced by 15-20 fold. Statistical and trend analysis was carried out to resolve the contribution of different facilities at a distance of 5 km (north and south) from the discharge point by log normal probability analysis and found that at 5 km south, the median value of "1"3"7Cs due to TAPS and FRP discharges were 3.7 mBq/l and 1.50 mBq/l respectively. The observed levels of "1"3"7Cs are of no consequences from the point of view of dose to members of the public. (author)

2005-11-23

39

Review of Constructed Subsurface Flow vs. Surface Flow Wetlands  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this document is to use existing documentation to review the effectiveness of subsurface flow and surface flow constructed wetlands in treating wastewater and to demonstrate the viability of treating effluent from Savannah River Site outfalls H-02 and H-04 with a subsurface flow constructed wetland to lower copper, lead and zinc concentrations to within National Pollutant Discharge Elimination System (NPDES) Permit limits. Constructed treatment wetlands are engineered systems that have been designed and constructed to use the natural functions of wetlands for wastewater treatment. Constructed wetlands have significantly lower total lifetime costs and often lower capital costs than conventional treatment systems. The two main types of constructed wetlands are surface flow and subsurface flow. In surface flow constructed wetlands, water flows above ground. Subsurface flow constructed wetlands are designed to ...

2004-09-01

40

Sustainable development at Canadian Electrolytic Zinc -- recent improvements  

Energy Technology Data Exchange (ETDEWEB)

A series of modifications which increased the capacity of Canadian Electrolytic Zinc's Valleyfield plant from 220,000 MT/year to 260,000 MT/year during the last decade is discussed, combined with an an overview of the plant's operations. The modifications included modernisation of the waste disposal methods and facilities, such as a new high-density sludge wastewater treatment process, a new process to remove selenium from weak acid solutions and the jarofix process. Roasting capacity also has been improved by recent investments in new cooling coils, rebricking, oxygen enrichment and process automation. In addition to increases in refining capacity, the improvements also enabled the company to minimize its impact on the environment and the community.

2001-07-01

41

Advanced Flue Gas Desulfurization (AFGD) Demonstration Project. Technical progress report No. 13, January 1, 1993--March 31, 1993  

Science.gov (United States)

The goal of this project is to demonstrate that, by combining state-of-the-art technology, highly efficient plant operation and maintenance capabilities and by-product gypsum sales, significant reductions of SO{sub 2} emissions can be achieved at approximately one-half the life cycle cost of a conventional Flue Gas Desulfurization (FGD) system. Further, this emission reduction is achieved without generating solid waste and while minimizing liquid wastewater effluent. Basically, this project entails the design, construction and operation of a nominal 600 MWe AFGD facility to remove SO{sub 2} from coal-fired power plant flue gas at the Northern Indiana Public Service Company`s Bailly Generating Station.

1994-08-01

42

State of work for services provided by the Waste Sampling and Characterization Facility for effluent monitoring  

International Nuclear Information System (INIS)

This document defines the services the Waste Sampling and Characterization Facility (WSCF) shall provide Effluent Monitoring (EM) throughout the calendar year for analysis. The internal memo contained in Appendix A identifies the samples Em plans to submit for analysis in CY-1995. Analysis of effluent (liquid and air discharges) and environmental (air, liquid, animal, and vegetative) samples is required using standard laboratory procedures, in accordance with regulatory and control requirements. This report describes regulatory reporting requirements and WSCF services and data quality objectives.

43

Waste monitoring system for effluents  

Energy Technology Data Exchange (ETDEWEB)

The waste monitoring system in use at Los Alamos National Laboratory`s Plutonium Facility, TA-55, is a computer-based system that proves real-time information on industrial effluents. Remote computers monitor discharge events and data moves from one system to another via a local area network. This report describes the history, system design, summary, instrumentation list, displays, trending screens, and layout of the waste monitoring system.

1995-07-01

44

Environmental assessment for the proposed effluent limitations guidelines, pretreatment standards, and new source performance standards for the centralized waste treatment industry  

Science.gov (United States)

This report assesses the water quality related benefits that would be expected if the US Environmental Protection Agency (EPA) adopts the proposed effluent limitations, guidelines and pretreatment standards for the Centralized Waste Treatment (CWT) Industry. EPA estimates that under baseline conditions 205 CWT facilities discharge approximately 5.22 million lbs/year of metal and organic pollutants.

1998-12-01

45

Reducing CSOs and giving the river back to the public: innovative combined sewer overflow control and riverbanks restoration of the St. Charles River in Quebec City.  

Science.gov (United States)

After the construction of its wastewater treatment plants, the City of Quebec began to implement overflow control in wet weather to ultimately meet the effluent discharge objectives, i.e. no more than two overflows per summer season in the St. Lawrence River and no more than four in the St-Charles River. After several years of studies to determine which management strategies would best suit the purpose, and to propose optimum solutions, a first project to implement optimal and predictive management in real time, called "Pilot", came to life in 1999. Construction in phases soon followed and the work was completed in the fall of 2009. As a result, requirements with regard to environmental rejects were met in two sectors, namely the St-Charles River and the Jacques-Cartier Beach, and aquatic recreational activities could resume. Meanwhile, the City also worked at giving back access to the water courses to the public by developing sites at the ...

2011-01-01

48

Microbial characterization of a radionuclide- and metal-contaminated waste site  

Energy Technology Data Exchange (ETDEWEB)

The operation of nuclear processing facilities and defense-related nuclear activities has resulted in contamination of near-surface and deep-subsurface sediments with both radionuclides and metals. The presence of mixed inorganic contaminants may result in undetectable microbial populations or microbial populations that are different from those present in uncontaminated sediments. To determine the impact of mixed radionuclide and metal contaminants on sediment microbial communities, we sampled a processing pond that was used from 1948 to 1975 for the disposal of radioactive and metal-contaminated wastewaters from laboratories and nuclear fuel fabrication facilities on the Hanford Site in Washington State. Because the Hanford Site is located in a semiarid environment with average rainfall of 159 mm/year, the pond dried and a settling basin remained after wastewater input into the pond ceased in 1975. ...

1993-04-01

49

Can we do it?  

International Nuclear Information System (INIS)

One wonders how a facility will cope with the new Clean Air Act Amendments (CAAA). Environmental engineers working in large companies' facilities and in corporate engineering groups already have an idea of how to comply with the regulations for chemical plant equipment leaks. (In fact, the rules will also affect process bins, wastewater, transfer and storage.) But those who work for smaller companies or who have assignments not directly tied to environmental affairs may not have access to the latest thinking on compliance. One of the first challenges in becoming aware of the CAAA regulations is learning the new language, which consists of acronyms, some containing other acronyms. NESHAP, for example, stands for national emissions standards for hazardous air pollutants. Prior to the CAAA, NESHAPs applied to a few specific chemicals, such as benzene. Now the proposed rules establish a HON, a hazardous organic NESHAP. ...

50

Environmental surveillance at Hanford for CY-1979  

Energy Technology Data Exchange (ETDEWEB)

Environmental data were collected for most environmental media including air, Columbia River water, external radiation, foodstuffs (milk, beef, eggs, poultry, and produce) and wildlife (deer, fish, and game birds), as well as soil and vegetation samples. In general, offsite levels of radionuclides attributable to Hanford operations during 1979 were indistinguishable from background levels. The data are summarized in the following highlights. Air quality measurements of NO/sub 2/ in the vicinity of the Hanford Site and releases of SO/sub 2/ onsite were well within the applicable federal and state standards. Particulate air concentrations exceed the standards primarily because of agricultural activities in the area. Discharges of waste water from Hanford facilities in the Columbia River under the National Pollution Discharge Elimination System (NPDES) permit were all within the parameter limits on the permit.

1980-04-01

51

Significance analysis of the leachate level in a solid waste landfill in a coastal zone using total water balance and slope stability alternatives  

Energy Technology Data Exchange (ETDEWEB)

The K site near Seoul began landfilling in 1992. The landfilled wastes include municipal solid waste (66.4%), construction residues (20.4%), water and wastewater sludges (trace levels), and hazardous waste (trace levels). The water content of the municipal solid waste is very high (47.3%); as a result, the leachate level (average E.L.) of the landfill, the design value of which is 7.0 m, was measured at 10.3 m in January 1995 and is increasing. The increase of leachate level in the landfill site causes a problem with slope stability. The leachate level at each disposal stage divided by the intermediate cover layer was calculated with the HELP (Hydrologic Evaluation of Landfill Performance) model and calibrated with the data measured from February 1993 to June 1995. Also, the hydraulic conductivities of the waste layer and the intermediate cover layer in each stage were calibrated continuously with HELP model analysis. To verify these results, the total water ...

1996-12-31

52

Effects of livestock wastewater variety and disinfectants on the performance of constructed wetlands in organic matters and nitrogen removal  

British Library Electronic Table of Contents (United Kingdom)

Background, aim and scope Treatment performance of constructed wetlands (CWs) is largely dependent on the characteristics of the wastewater. Although livestock wastewater is readily biodegradable in general, its variety in biodegradability can still be significant in practice. In addition, it is a common practice to periodically use disinfectants in livestock activities for health concerns. Obviously, the residual of the disinfectants in livestock wastewater may have serious inhibitory effect on the microbial activities during wastewater treatment. Thus, the main objective of this study was to examine the variety of livestock wastewater in biodegradability and its effect on the performance of a pilot scale tidal flow CWs (TFCWs) in organic matter and nitrogen removal. Furthermore, investig...

2011-01-01

53

Research and development of photovoltaic power system; Taiyoko hatsuden system no jissho kenkyu  

Energy Technology Data Exchange (ETDEWEB)

This paper reports the result obtained during fiscal 1994 on a demonstration research on photovoltaic power generating systems. Solar cells with an output of 750 kW, storage battery facilities with an output of 3,058 kWh, three DC-AC converters with a rating of 250 kW, and a diesel generator with an output of 300 kW having been installed up to the previous fiscal year were combined to perform comprehensive adjustments and tests such as battery charge/discharge tests and AC parallel operation tests. The battery charge/discharge tests revealed that the 10 hour rate discharge capacity meets the specifications, and the batteries are free of deterioration after a demonstration operation of about 4.5 months. Difference between the power generation record and the planned value is thought due to the following reasons: the array output data in a power line connected system come about 90% of the simulation result ...

1994-12-01

54

A framework for assessing relative risks associated with multiple stressors in Port Valdez, Alaska  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this assessment is to develop a versatile process that will provide a mechanism for evaluating both present and future risks to this environment. Much of the regulatory and environmental interest in the port has centered around a Ballast Water Treatment facility that treats and discharges up to 30 mgd of oily ballast water brought in by crude oil tankers. However, six point discharges and other potential sources of pollution exist in the area. The authors have delineated eleven subareas in the port in order to identify the potential anthropogenic stressors, as well as the receptors that could be exposed to these stressors. Potential effects were then characterized for each exposure. Each component is ranked and integrated, resulting in a relative risk estimate in each subarea. Both the discernible risks, based on available data, and the data gaps are presented. Uncertainty is expressed as a range of high and ...

1995-12-31

55

Economic viability of anaerobic digestion  

Energy Technology Data Exchange (ETDEWEB)

The industrial application of anaerobic digestion is a relatively new, yet proven waste treatment technology. Anaerobic digestion reduces and upgrades organic waste, and is a good way to control air pollution as it reduces methane and nitrous gas emissions. For environmental and energy considerations, anaerobic digestion is a nearly perfect waste treatment process. However, its economic viability is still in question. A number of parameters - type of waste (solid or liquid), digester system, facility size, product quality and end use, environmental requirements, cost of alternative treatments (including labor), and interest rates - define the investment and operating costs of an anaerobic digestion facility. Therefore, identical facilities that treat the same amount and type of waste may, depending on location, legislation, and end product characteristics, reveal radically different costs. A good approach for evaluating the ...

1996-01-01

56

From tankers to tissues : tracking the degradation and fate of oil discharges in Port Valdez, Alaska  

Energy Technology Data Exchange (ETDEWEB)

An average of 9 million gallons per day of oil-contaminated ballast water off loaded from tankers are treated at the Alyeska Pipeline Service Company Ballast Water Treatment Facility at the terminus of the Trans-Alaska Pipeline in Port Valdez, Alaska. This paper focuses on the results of 2 Prince William Sound Regional Citizens' Advisory Council monitoring programs which detail changes in the chemical composition of treated ballast water as it moves from tankers through the facility and subsequently traces the effluent hydrocarbons into the receiving environment of Port Valdez. The treatment facility involves gravity separation tanks, dissolved air flotation cells and biological treatment tanks. Effluent containing traces of volatile aromatics, including benzene, toluene, ethylbenzene and xylenes, low levels of oil, saturated hydrocarbons and polycyclic aromatic hydrocarbons is being continuously ...

2005-07-01

57

Wastewater Treatment Software Solutions on Environmental Expert  

Wastenet

... TOXCHEM+ - Wastewater Predictive Fate by Hydromantis Environmental Software Solutions, Inc. TOXCHEM+ is regarded as the most reliable and ... TOXCHEM+ is EPA-approved for estimating ... »Read more » Contact now / Request quote 0 Comments ...

58

Recovery of energy from the food industry by anaerobic purification of its wastewaters  

Energy Technology Data Exchange (ETDEWEB)

The energy recovery by anaerobic purification of wastewaters from olive oil manufactured is reported. The process efficiency is 82%, and the gas (CH4-CO2) yield is 850 L/kg eliminated BOD.

1980-01-01

59

The cascad spent fuel dry storage facility  

International Nuclear Information System (INIS)

France has a wide variety of experimental spent fuels different from LWR spent fuel discharged from commercial reactors. Reprocessing such fuels would thus require the development and construction of special facilities. The French Atomic Energy Commission (CEA) has consequently opted for long-term interim storage of these spent fuels over a period of 50 years. Comparative studies of different storage concepts have been conducted on the basis of safety (mainly containment barriers and cooling), economic, modular design and operating flexibility criteria. These studies have shown that dry storage in a concrete vault cooled by natural convection is the best solution. A research and development program including theoretical investigations and mock-up tests confirmed the feasibility of cooling by natural convection and the validity of design rules applied for fuel storage. A facility called CASCAD was built at the CEA's ...

1991-04-14

62

Innovative coke oven gas cleaning system for retrofit applications. Quarterly environmental monitoring report No. 1, January 1, 1991--June 30, 1991  

Energy Technology Data Exchange (ETDEWEB)

The coke plant at the Sparrows Point Plant consist of three coke oven batteries and two coal chemical plants. The by-product coke oven gas (COG) consists primarily of hydrogen, methane, carbon monoxide, nitrogen and contaminants consisting of tars, light oils (benzene, toluene, and xylene) hydrogen sulfide, ammonia, water vapor and other hydrocarbons. This raw coke oven gas needs to be cleaned of most of its contaminants before it can be used as a fuel at other operations at the Sparrows Point Plant. In response to environmental concerns, BSC decided to replace much of the existing coke oven gas treatment facilities in the two coal chemical Plants (A and B) with a group of technologies consisting of: Secondary Cooling of the Coke oven Gas; Hydrogen Sulfide Removal; Ammonia Removal; Deacification of Acid Gases Removed; Ammonia Distillation and Destruction; and, Sulfur Recovery. This combination of technologies will replace the existing ammonia removal system, the ...

1992-08-24

63

Innovative coke oven gas cleaning system for retrofit applications  

Energy Technology Data Exchange (ETDEWEB)

The coke plant at the Sparrows Point Plant consist of three coke oven batteries and two coal chemical plants. The by-product coke oven gas (COG) consists primarily of hydrogen, methane, carbon monoxide, nitrogen and contaminants consisting of tars, light oils (benzene, toluene, and xylene) hydrogen sulfide, ammonia, water vapor and other hydrocarbons. This raw coke oven gas needs to be cleaned of most of its contaminants before it can be used as a fuel at other operations at the Sparrows Point Plant. In response to environmental concerns, BSC decided to replace much of the existing coke oven gas treatment facilities in the two coal chemical Plants (A and B) with a group of technologies consisting of: Secondary Cooling of the Coke oven Gas; Hydrogen Sulfide Removal; Ammonia Removal; Deacification of Acid Gases Removed; Ammonia Distillation and Destruction; and, Sulfur Recovery. This combination of technologies will replace the existing ammonia removal system, the ...

1992-08-24

64

Development of radioisotope tracer technology  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to develop the radioisotope tracer technology, which can be used in solving industrial and environmental problems and to build a strong tracer group to support the local industries. In relation to the tracer technology in 1999, experiments to estimate the efficiencies of a sludge digester of a waste water treatment plant and a submerged biological reactor of a dye industry were conducted. As a result, the tracer technology for optimization of facilities related to wastewater treatment has been developed and is believed to contribute to improve their operation efficiency. The quantification of the experimental result was attempted to improve the confidence of tracer technology by ECRIN program which basically uses the MCNP simulation principle. Using thin layer activation technique, wear of tappet shim was estimated. Thin layer surface of a tappet shim was irradiated by proton beam and the correlation between the ...

2000-04-01

65

Water | Editorial Board  

Wastenet

...Tota-MaharajE-Mail: Interests: water and wastewater treatment, environmental engineering and sustainable systems; sustainable water management; sustainable urban drainage systems (SUDS); combined renewable energy applications with reverse osmosis desalination; microbial fuel cells for bioenergy production and treatment of urban wastewater; solar photocatalytic treatment and disinfection of water/wastewater Dr. Simon Toze CSIRO Land and Water, Queensland Bioscience Precinct - St Lucia, 306 Carmody Road, St Lucia QLD 4067,...

66

Heavy metals in industrial wastewater determined by radionuclide x-ray fluorescence analysis and their effects on Allium cepa root tip cells  

International Nuclear Information System (INIS)

Radionuclide x-ray fluorescence method was used in the determination of Cr, Ni and other heavy metals content in wastewater of an engineering plant taken both before and after chemical treatment. Toxic effects of the wastewaters using Allium cepa root tip cells were tested. (author) 8 refs.; 2 tabs.

1994-05-01

67

Determination of heavy metals in industrial wastewaters and their influence on activated sludge biocenose  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence method with a Si/Li semiconductor detector and "2"3"8Pu exciting source was used in the determination of Cr, Fe, Ni, Cu, and Zn content in industrial wastewaters. Simultaneously, the effects of the wastewaters on activated sludge biocenose were evaluated. (author) 6 refs.; 1 fig.; 1 tab.

1994-03-01

68

Simultaneous ozonation kinetics of phenolic acids present in wastewaters  

Energy Technology Data Exchange (ETDEWEB)

Among the several chemical processes conducted for the removal of organic matter present in wastewaters coming from some agro-industrial plants (wine distilleries, olive oil mills, etc), the oxidation by ozone has shown a great effectiveness in the destruction of specially refractory pollutants: it is demonstrated that the biodegradability of those wastewaters increases aflcer an ozonation pretreatment. Their great pollutant character is imputed to the presence of some organic compounds, like phenols and polyphenols, which are toxic and inhibit the latter biological treatments. In this research, a competitive kinetic procedure reported by Clurol and Nekouinaini is applied to determine the degradation rate constants by ozone of several phenolic acids which are present in the wastewaters from the olive oil obtaining process. The resulting kinetic expressions for the ozonation reactions are useful for the successful design and ...

1996-12-31

69

B Plant treatment, storage, and disposal (TSD) units inspection plan  

Energy Technology Data Exchange (ETDEWEB)

This inspection plan is written to meet the requirements of WAC 173-303 for operations of a TSD facility. Owners/operators of TSD facilities are required to inspection their facility and active waste management units to prevent and/or detect malfunctions, discharges and other conditions potentially hazardous to human health and the environment. A written plan detailing these inspection efforts must be maintained at the facility in accordance with Washington Administrative Code (WAC), Chapter 173-303, ``Dangerous Waste Regulations`` (WAC 173-303), a written inspection plan is required for the operation of a treatment, storage and disposal (TSD) facility and individual TSD units. B Plant is a permitted TSD facility currently operating under interim status with an approved Part A Permit. Various operational systems and locations within or under ...

1996-04-26

70

Dynamic positive column in long-gap barrier discharges  

CERN Document Server

A simple analytical model of the barrier discharge in a long gap between opposing plane electrodes is developed. It is shown that the plasma density becomes uniform over large part of the gap in the course of the discharge development, so that one can speak of a formation of a dynamic positive column. The column completely controls the dynamics of the barrier discharge and determines such characteristics as the discharge current, discharge duration, light output, etc. Using the proposed model, all discharge parameters can be easily evaluated

2005-01-01

71

2007 SB14 Source Reduction Plan/Report  

Energy Technology Data Exchange (ETDEWEB)

Aqueous solutions (mixed waste) generated from various LLNL operations, such as debris washing, sample preparation and analysis, and equipment maintenance and cleanout, were combined for storage in the B695 tank farm. Prior to combination the individual waste streams had different codes depending on the particular generating process and waste characteristics. The largest streams were CWC 132, 791, 134, 792. Several smaller waste streams were also included. This combined waste stream was treated at LLNL's waste treatment facility using a vacuum filtration and cool vapor evaporation process in preparation for discharge to sanitary sewer. Prior to discharge, the treated waste stream was sampled and the results were reviewed by LLNL's water monitoring specialists. The treated solution was discharged following confirmation that it met the discharge criteria. A major ...

2007-07-24

72

Challenges in environmental radiological surveillance around nuclear facilities  

International Nuclear Information System (INIS)

To accomplish the environmental radiological surveillance need of India's ambitious nuclear power programme, Health Physics Division is infusing new technologies and improved analytical techniques for day to day measurements of various radionuclides in different environmental matrices. It is essential to have techniques for measuring the concentration of radionuclides just above the background level since the discharges from the nuclear facilities are very low i.e. in the range of 5-10% of the prescribed discharge limits by the regulatory bodies. In view of developing ultra-sensitive techniques, the aim of ongoing programmes of the division is to meet the challenges of measuring ultra trace level of radioactivity by adopting state of art new instrumentation and improved sample processing techniques. This will allow us to measure the lowest level of radioactivity (3H, 90Sr, 137Cs, 239+240Pu, etc.) in the environment and ...

2007-06-05

73

Application of electro-Fenton oxidation for the detoxification of olive mill wastewater phenolic compounds  

Energy Technology Data Exchange (ETDEWEB)

Olive mill effluent (OMW) is an example of a wastewaters containing high concentrations of recalcitrant and toxic compounds which are polyphenolics of different molecular weight. It causes disposal problems because they contain powerful pollutants. Treatment and detoxification of phenolic fraction extracted from olive mill wastewaters as well as a synthetic phenolic mixture was investigated by electro-Fenton method. Results shows that this method is highly efficient in polymerising low molecular mass phenolics and removing a large amount of recalcitrant polyphenolic compounds. This treatment decreased 78% of the toxicity which sustained a good anaerobic post-treatment. (orig.)

2003-07-01

75

Risk analysis in oil spill response planning  

Energy Technology Data Exchange (ETDEWEB)

Tiered response is a basic approach to emergency plans, including oil spill response (OSR). This paper delineates a huge set of accidental scenarios within a certain tier of response generated by a computer during risk assessment. Parameters such as the amount of oil spilled, duration of discharge and types of losses should be provided in OSR scenarios. Examples of applications include offshore installations, sub sea or onshore pipelines, and localized onshore facilities. The paper demonstrates how to use risk analysis results for delineating all likely spills into groups that need a specific tier response. The best world practices and Russian regulatory approaches were outlined and compared. Corresponding algorithms were developed and their application in pipelines was presented. The algorithm combines expert's skills and spill trajectory modeling with the net environmental benefit analysis principle into the incident specific ...

2005-07-01

76

Oil-tanker waste-disposal practices: A review  

Energy Technology Data Exchange (ETDEWEB)

In the spring of 1991, the Environmental Protection Agency, Region 10 (EPA), launched an investigation into tanker waste disposal practices for vessels discharging ballast water at the Alyeska Pipeline Services Company's Ballast Water Treatment (BWT) facility and marine terminal in Valdez, Alaska. It had been alleged that the Exxon Shipping Company was transferring 'toxic wastes originating in California' to Valdez. In response, EPA decided to examine all waste streams generated on board and determine what the fate of these wastes were in addition to investigating the Exxon specific charges. An extensive Information Request was generated and sent to the shipping companies that operate vessels transporting Alaska North Slope Crude. Findings included information on cargo and fuel tank washings, cleaning agents, and engine room waste.

1992-01-01

77

Environmental assessment of proposed effluent limitations guidelines and standards for the transportation equipment cleaning category: Volume 1. Final report  

Science.gov (United States)

This environmental assessment quantifies the water quality-related benefits for Transportation Equipment Cleaning (TEC) facilities based on site-specific analyses of current conditions and the conditions that would be achieved by process changes under proposed BAT (Best Available Technology) and PSES (Pretreatment Standards for Existing Sources) controls. The US Environmental Protection Agency (EPA) estimated instream pollutant concentrations for 157 priority and nonconventional pollutants from three subcategories (barge-chemical and petroleum, rail-chemical, and truck-chemical) of direct and indirect discharges using stream dilution modeling. The potential impacts and benefits to aquatic life are projected by comparing the modeled instream pollutant concentrations to published EPA aquatic life criteria guidance or to toxic effect levels.

1998-05-01

78

Molecular Characterization of Cryptosporidium Oocysts in Samples of Raw Surface Water and Wastewater  

UK PubMed Central (United Kingdom)

Recent molecular characterizations of Cryptosporidium parasites make it possible to differentiate the human-pathogenic Cryptosporidium parasites from those that do...Full Text Available

2001-03-01

79

Closed Cycle Bleach Kraft Pulp Production; NICE3 Forest Products Project Fact Sheet  

Energy Technology Data Exchange (ETDEWEB)

Fact sheet written for the NICE3 Program on a new chlorine-free process for pulping and bleaching wastewater.

2000-10-30

80

Ashbrook Simon-Hartley Profile on Environmental Expert  

Wastenet

...been a world leader in the design, manufacture and installation of high quality precision-engineered systems for water and wastewater treatment fo Create Free Account ...

81

Ashbrook Simon-Hartley Profile on Environmental Expert  

Wastenet

...been a world leader in the design, manufacture and installation of high quality precision-engineered systems for water and wastewater treatment fo Bulletins Environmental Expert ...

82

Superfund Record of Decision (EPA Region 1): Baird and McGuire, MA. (Third remedial action), September 1989  

Energy Technology Data Exchange (ETDEWEB)

The Baird and McGuire site is a former chemical manufacturing facility in northwest Holbrook, Massachusetts, approximately 14 miles south of Boston. From 1912 to 1983 the company operated a chemical manufacturing and batching facility on the property. Manufactured products included herbicides, pesticides, disinfectants, soaps, floor waxes and solvents. Waste disposal methods at the site included direct discharge into the soil, nearby brook and wetlands, and a former gravel pit (now covered) in the eastern portion of the site. EPA conducted a removal action at the site in 1983 after a waste lagoon overflowed spreading contaminants into the Cochato River. The company ceased operating shortly thereafter. A second removal action was conducted in 1985, following the discovery of dioxin in site soils. EPA also conducted an Initial Remedial Measure at the site from 1985 through 1987 which involved constructing a new water main to ...

1989-09-14

83

Proposed fuel cycle for the Integral Fast Reactor  

Energy Technology Data Exchange (ETDEWEB)

One of the key features of ANL's Integral Fast Reactor (IFR) concept is a close-coupled fuel cycle. The proposed fuel cycle is similar to that demonstrated over the first five to six years of operation of EBR-II, when a fuel cycle facility adjacent to EBR-II was operated to reprocess and refabricate rapidly fuel discharged from the EBR-II. Locating the IFR and its fuel cycle facility on the same site makes the IFR a self-contained system. Because the reactor fuel and the uranium blanket are metals, pyrometallurgical processes (shortned to ''pyroprocesses'') have been chosen. The objectives of the IFR processes for the reactor fuel and blanket materials are to (1) recover fissionable materials in high yield; (2) remove fission products adequately from the reactor fuel, e.g., a decontamination factor of 10 to 100; and (3) upgrade the concentration of plutonium in uranium ...

1985-01-01

84

Plasma dynamics in the PF-1000 device under full-scale energy storage: II. Fast electron and ion characteristics versus neutron emission parameters and gun optimization perspectives  

International Nuclear Information System (INIS)

Electron and ion beam dynamics of the PF-1000 facility were investigated for the first time at its upper energy limit (?1 MJ) in relation to neutron emission, the pinch's plasma ('target') characteristics and some other parameters with the help of a number of diagnostics with ns temporal resolution. Special attention was paid to the temporal and the spatial cross correlations of different phenomena. Results of these experiments are in favour of a neutron emission model based on ion beam-plasma interaction with three important features: (1) the plasma target is hot and confined during a few 'inertial confinement times'; (2) the ions of the main part of the beam are magnetized and entrapped around the pinch plasma target for a period longer than the characteristic time of the plasma inductive storage system and (3) ion-ion collisions (both fusion collisions, due to head-on impacts and Coulomb collisions) are responsible for neutron emission. Analysis has shown that ...

2007-06-21

85

Environmental assessment of the brine pipeline replacement for the Strategic Petroleum Reserve Bryan Mound Facility in Brazoria County, Texas  

Energy Technology Data Exchange (ETDEWEB)

The Department of Energy (DOE) has prepared an environmental assessment (EA), DOE/EA-0804, for the proposed replacement of a deteriorated brine disposal pipeline from the Strategic Petroleum Reserve (SPR) Bryan Mound storage facility in Brazoria County, Texas, into the Gulf of Mexico. In addition, the ocean discharge outfall would be moved shoreward by locating the brine diffuser at the end of the pipeline 3.5 miles offshore at a minimum depth of 30 feet. The action would occur in a floodplain and wetlands; therefore, a floodplain/wetlands assessment has been prepared in conjunction with this EA. Based on the analyses in the EA, DOE has determined that the proposed action is not a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act (NEPA) of 1969 (42 USC. 4321, et seg.). Therefore, the preparation of an Environmental Impact Statement (EIS) is not required, ...

1993-09-01

86

Control of microbially generated hydrogen sulfide in produced waters  

Energy Technology Data Exchange (ETDEWEB)

Production of hydrogen sulfide in produced waters due to the activity of sulfate-reducing bacteria (SRB) is a potentially serious problem. The hydrogen sulfide is not only a safety and environmental concern, it also contributes to corrosion, solids formation, a reduction in produced oil and gas values, and limitations on water discharge. Waters produced from seawater-flooded reservoirs typically contain all of the nutrients required to support SRB metabolism. Surface processing facilities provide a favorable environment in which SRB flourish, converting water-borne nutrients into biomass and H{sub 2}S. This paper will present results from a field trial in which a new technology for the biochemical control of SRB metabolism was successfully applied. A slip stream of water downstream of separators on a produced water handling facility was routed through a bioreactor in a side-steam device where microbial growth was allowed to ...

1995-12-31

87

Radionuclide X-ray fluorescence determination of Cr, Fe, Cu, Zn,and Pb in industrial wastewaters after preconcentration of determined elements  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis was used for the determination of Cr, Fe, Cu, Zn and Ph in industrial wastewaters (from surface treatment of metals and glasses) after precipitation of determined elements by 8-hydroxyquinoline. (author).

1997-01-01

88

Pilot scale hybrid processes for olive mill wastewater treatment, energy production and water reuse: comparison between fungal and electro-coagulation pre-treatments  

Energy Technology Data Exchange (ETDEWEB)

Olive oil mill wastewaters (OMW) cause disposal problems because they contain powerful pollutants such as phenolic compounds. Complete biodegradation or removal of these compounds is hardly achieved by a single treatment method. In this work, we investigated 2 integrated technologies for the treatment of the recalcitrant contaminants of OMW, allowing water recovery and reuse for agricultural purposes. (Author)

2009-07-01

89

NAME=\\  

Wastenet

... Biodegradable plastics have the potential to be used in various flushable sanitary product applications such as sanitary towels, colostomy bags and other absorbent products. In addition, effluent from recycling activities must be treated in wastewater treatment plants and may contain biodegradable plastics. Flushable biodegradable plastics can have an adverse impact on wastewater treatment plants due to the very fast throughputs, typically 4 to 8 hours, from the drain to the plant. This length of time is insufficient for many biodegradable plastics to lose their structure. Such plastics can ...

90

Development document for proposed effluent limitations guidelines and standards for the transportation equipment cleaning category  

Energy Technology Data Exchange (ETDEWEB)

Contents of this report are under the following topical sections: Legal Authority; Summary and Scope; Data Collection Activities; Industry Description; Industry Subcategorization; Water Use and Wastewater Characterization; Pollutants Selected for Regulation; Pollution Prevention and Wastewater Treatment Technologies; Development of Control and Treatment Options; Costs of Technology Bases for Regulations; Pollutant Reduction Estimates; Non-Water Quality Impacts; Implementation of Proposed Effluent Limitation Guidelines and Standards; Analytical Methods; and Glossary.

1998-05-01

91

Thin-film evaporator recovers solvents continuously  

Energy Technology Data Exchange (ETDEWEB)

Reclaimed Energy Company, Inc., Connersville, IN, receives waste generated from a wide variety of industrial applications which include paint, printing and degreasing companies. The wastes are stored in separate tanks and then distilled in batches (pot distillation). The recovered solvents can be returned to the originator. The residue, left after the solvents are distilled, is disposed of using an environmentally safe, economical procedure. The company worked with an engineering and fabrication firm to develop a continuous processing system that employs a mechanically agitated thin-film evaporator to distill the solvents. Successful performance of the evaporator was ensured by processing samples of solvents through the evaporator manufacturer's pilot plant facilities before the full-sized system was designed. Reclaimed Energy Company, Inc., has realized a number of advantages by going from pot distillation to the agitated thin-film evaporator system to ...

1985-11-01

92

Non-Traditional In Situ Vitrification - A Technology Demonstration at Los Alamos National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

The Department of Energy (DOE) Subsurface Contamination Focus Area (SCFA) sponsored a technology demonstration of non-traditional in situ vitrification (NTISV) at Los Alamos National Laboratory (LANL). The project team for this demonstration included MSE Technology Applications, Inc., Geosafe Corporation, and LANL. The technology demonstration involved the performance of two large-scale test melts. The first, referred to as the ''cold'' test, was performed on a simulated absorption bed that contained surrogate contaminants. The cold test was conducted in April 1999. The second demonstration, referred to as the ''hot'' test, took place at LANL's Material Disposal Area (MDA) V in April 2000. The hot test was conducted on a portion of an absorption bed that received radionuclide and metal-contaminated wastewater from a laundry facility and a research laboratory from ...

2003-02-25

93

Fuel ignition by high voltage capacitive discharges  

Energy Technology Data Exchange (ETDEWEB)

The study examined the possibility for fuel ignition by spark discharge caused by induction effects under high voltage transmission lines. Theoretical background information on capacitive spark discharges and fuel ignition processes is given. Laboratory experiments were conducted to test the dependence of fuel ignition on three parameters: impedance in discharge path, multiple discharges, and larger electrode shapes. The results of these tests are discussed in terms of fuel ignition possibilities under high voltage transmission lines.

1983-03-01

94

Biotoxicity characterization of a produced-water discharge in Wyoming  

International Nuclear Information System (INIS)

The objectives of this paper are to document the physicochemical and aquatic toxicological quality of a beneficial-use produced-water discharge and its effect on a receiving stream in Wyoming. Fish and water-flea survival, growth, and reproduction tests indicated that the discharge and all other sampling stations passed the state effluent biomonitoring acute toxicity testing endpoints. while benthic macroinvertebrates were absent at the discharge point designated by the Natl. Pollutant Discharge Elimination System (NPDES), productive and reproducing populations were present at all other downstream and mixing-zone stations. This investigation confirmed the validity of the beneficial-use subcategory for this oilfield discharge.

95

Understanding consumption-related sucralose emissions - A conceptual approach combining substance-flow analysis with sampling analysis  

British Library Electronic Table of Contents (United Kingdom)

This paper explores the potential of combining substance-flow modelling with water and wastewater sampling to trace consumption-related substances emitted through the urban wastewater. The method is exemplified on sucralose. Sucralose is a chemical sweetener that is 600 times sweeter than sucrose and has been on the European market since 2004. As a food additive, sucralose has recently increased in usage in a number of foods, such as soft drinks, dairy products, candy and several dietary products. In a field campaign, sucralose concentrations were measured in the inflow and outflow of the local wastewater treatment plant in Linkoping, Sweden, as well as upstream and downstream of the receiving stream and in Lake Roxen. This allows the loads emitted from the city to be estimated. A method c...

2010-01-01

96

Remazol Black B removal from aqueous solutions and wastewater using weakly basic anion exchange resins  

British Library Electronic Table of Contents (United Kingdom)

In this study, the use of the weakly basic anion exchange resins of phenol-formaldehyde (Amberlyst A 23), polyacrylate (Amberlite IRA 67) and polystyrene (Lewatit MonoPlus MP 62) matrices for removal of the reactive dye Remazol Black B (RBB) from aqueous solution and wastewater were investigated. RBB sorption on the anion exchangers was a time dependent process. Color reduction percentiles of 75.2, 33.9 and 25.1% in wastewater treatment were found after 216 h of phase contact time with Lewatit MonoPlus MP 62, Amberlyst A 23 and Amberlite IRA 67, respectively. Inorganic salts and anionic surfactant action influenced RBB uptake by the anion exchangers. The amounts of dye retained by the anion exchangers increased with a rise in temperature. The maximum sorption capacities calculated from the...

2011-01-01

97

Analysis of a Fast Spectrum Irradiation Facility in the High Flux Isotope Reactor  

Energy Technology Data Exchange (ETDEWEB)

The Global Nuclear Energy Partnership (GNEP) is proposing to develop a sodium-cooled fast-spectrum reactor (SFR) to transmute and consume actinides from discharged nuclear fuel. To meet performance objectives, new and advanced fuels and targets need to be developed. The fuels to be irradiated include metal and oxide mixed actinides (U-Np-Pu-Am-Cm); for the target concept, Am-Cm has been considered. A significant part of the development process is the irradiation of the fuel and cladding in a prototypic fast reactor environment to determine the performance under irradiation. Analysis results are presented in this paper for a fast-neutron irradiation facility design based on the large fast neutron flux available in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) combined with the use of a strongly-absorbing thermal neutron shield. Several designs were assessed; the preferred concept consists of a three-pin design with ...

2008-09-01

98

Electrical Discharge Machining (EDM) Gun Barrel Bore and ...  

Science.gov (United States)

... Accession Number : ADB006226. Title : Electrical Discharge Machining (EDM) Gun Barrel Bore and Rifling Feasibility Study. ...

1974-09-01

99

EPA - Stormwater Discharges from Construction Activities  

Science.gov (United States)

discharges. Proposed Stormwater ELG from Construction Sites - EPA has proposed effluent limitations guidelines (ELGs) and new source performance standards (NSPS) to control...

2011-10-14

100

Environmental releases for calendar year 1997  

Energy Technology Data Exchange (ETDEWEB)

This report fulfills the annual environmental release reporting requirements of US Department of Energy (DOE) Order 5400.1. This report provides supplemental information to the Hanford Site Environmental Report (PNNL-11795). The Hanford Site Environmental Report provides an update on the environmental status of the Hanford Site. The sitewide annual report summarizes the degree of compliance with applicable environmental regulations and informs the public concerning the impact of Hanford Site operations on the surrounding environment. Like the Hanford Site Environmental Report, this annual report presents a summary of the environmental releases from facilities and activities managed by the Fluor Daniel Hanford, Incorporated (FDH), and Bechtel Hanford, Incorporated (BHI). In addition to the summary data, this report also includes detailed data on air emissions, liquid effluents, and hazardous substances released to the environment during calendar year 1997. ...

1998-08-25

101

Using long term biological monitoring data to evaluate the recovery of disturbed systems  

International Nuclear Information System (INIS)

Biological monitoring has been conducted in industrially impacted streams near US Department of Energy facilities in Tennessee and Kentucky for almost ten years. A comprehensive Biological Monitoring and Abatement Program, which was developed to meet National Pollutant Discharge Elimination System permit requirements, includes tasks on (1 ) toxicity testing; (2) bioaccumulation in aquatic and terrestrial biota; (3) bioindicators of fish health; and (4) fish, macroinvertebrate, and periphyton community surveys. These studies have been used successfully to characterize spatial trends and demonstrate temporal recovery resulting from remedial actions and pollution abatement activities, identify contaminant sources, and provide data for conducting ecological risk assessments. The program uses multiple lines of evidence to evaluate stream recovery and illustrates the importance of using an integrated approach when determining stream health. An ...

1995-11-05

102

Shielding and Criticality Safety Analysis of KSC-1 Cask for the High Burnup PWR Spent Fuels  

International Nuclear Information System (INIS)

KSC-1 (KAERI Shipping Cask-1) was designed and manufactured with a pure domestic technology in 1985 in order to transport a PWR spent fuel assembly from nuclear power plant to PIEF (Post-Irradiation Examination Facility) of KAERI. Since the first transportation of the fuel assembly from Kori-1 NPP was carried out by the cask in 1987, 19 shipments for the PWR spent fuels have been done successfully by now. Maximum discharge burnup of PWR in Korea has been extended from the late 1990s in order to reduce the cost of power generation. From this cause, allowable design values of the initial enrichment and the cooling time for the cask have been changed three times: year 2003, 2007 and 2010. Radiation shielding and criticality of KSC-1 were analyzed for all the PWR fuel type irradiated in Korea NPP to renew the design approval

2010-10-01

103

Remediation process technology for ground water  

Energy Technology Data Exchange (ETDEWEB)

The operation of industrial facilities has generally resulted in contamination of the surrounding soils and ground water. A variety of methods have been proposed for the remediation of contaminated sites. This paper presents new process technology that is capable of performing treatment on ground water or soil washing leachates. The process is targeted to treat low levels of radioactivity, organics and heavy metals present in the aqueous solutions, to be easily transported and provide simple operation on-site and provide an effluent that meets the specified discharge quality. The purification process involves sequential chemical treatment and filtration. The paper will describe the development of the technology and review the current progress in its use to remediate contaminated sites at Chalk River. The application of the process technology has demonstrated that the ambitious goal of setting the effluent targets to meet the drinking water ...

1993-12-31

104

Remediation process technology for ground water  

International Nuclear Information System (INIS)

The operation of industrial facilities has generally resulted in contamination of the surrounding soils and ground water. A variety of methods have been proposed for the remediation of contaminated sites. This paper presents new process technology that is capable of performing treatment on ground water or soil washing leachates. The process is targeted to treat low levels of radioactivity, organics and heavy metals present in the aqueous solutions, to be easily transported and provide simple operation on-site and provide an effluent that meets the specified discharge quality. The purification process involves sequential chemical treatment and filtration. The paper will describe the development of the technology and review the current progress in its use to remediate contaminated sites at Chalk River. The application of the process technology has demonstrated that the ambitious goal of setting the effluent targets to meet the drinking water ...

1993-09-05

105

Primary coolant depressurization facility  

Energy Technology Data Exchange (ETDEWEB)

In a PWR type reactor, a primary coolant circuit system using a steam generator is adopted in order to accelerate depressurization of a primary coolant circuit upon small rupture LOCA in which the pressure of the primary coolant circuit is moderately depressurized. A secondary coolant circuit depressurization valve is disposed to a main steam pipeline. The valve has a performance of automatically opening to remove heat by evaporation of water stored in SG for a short period of time when the pressure in the primary circuit is decreased to about 50kg/cm[sup 2] upon occurrence of LOCA or the like. Then, the secondary side of the SG is depressurized to about atmospheric pressure and gravitational water injection from a condensate tank is started. Further, a gas vent valve is disposed to a water chamber of the steam generator. The valve has a performance of automatically opening to discharge incondensible gas mixed to the primary coolant circuit to the outside of the ...

1992-10-14

106

Environmental monitoring carried out by an association: the citizen watchdog of radioactivity in the environment; La surveillance de l'environnement exercee par une association: l'observatoire citoyen de la radioactivite dans l'environnement  

Energy Technology Data Exchange (ETDEWEB)

ACRO, a NGO equipped with a laboratory to measure radioactivity, runs the Citizen Watchdog of Radioactivity in the Environment. Involving many volunteers, it monitors regularly the French coast of the Channel and many rivers of the North half of France. It also makes investigations in other places. Such an action is aimed to supplement the official monitoring, not to replace it, in order to answer to the worries of the population. This monitoring shows that some radioelements, such as iodine 129, cobalt 60, tritium, etc. released in the environment by nuclear facilities can be detected on very large areas. Carbon 14 was detected up to almost 4 times the background in vegetables around the reprocessing plant of La Hague. ACRO also sits in many official committees to transmit the point of view of the populations exposed to the radioactive pollution. It is lobbying for a decrease of the release authorization, especially for the elements that are ...

2010-06-15

107

Environmental management plan for the Jhario coalfield - India  

Energy Technology Data Exchange (ETDEWEB)

An Environmental Management Plan (EMP) for the Jharia Coalfield (JCF) was recently completed as part of a World Bank funded project. The JCF, 260 km west of Calcutta, comprises 450 km{sup 2}. Bharat Coking Coal Limited (BCCL) operates an area of 258 km{sup 2}. Coal mining has been conducted for more than 100 years. There are severe constraints to mining due to geology, coal fires and the large population. BCCL counterpart staff participated actively in all aspects of the work. Air and water are heavily polluted, however, mining operations contribute only to a limited extent to the total pollution. Water contamination is generally due to inadequate sewage treatment and discharge from non-mine facilities such as power plants. The large area disturbed by mining to date will increase, as open pit mining operations are expected to expand significantly. Reclamation to date is generally confined to planting of trees. Areas where cost effective ...

1997-12-31

108

Development of PHWR fuel fabrication in Korea  

Energy Technology Data Exchange (ETDEWEB)

Korea Advanced Energy Research Institute (KAERI) started a research project to develop the PHWR (CANDU) nuclear fuel fabrication technology in 1981. Based on the results of the intensive developmental work, several prototype fuel bundles were fabricated and tested in the Hot Test Loop at KAERI continuously in 1983 and 1984. After that, irradiation test and post-irradiation examination were carried out for two KAERI-made fuel bundles at Chalk River Nuclear Laboratories in Canada in 1984. Since the results of in-pile and out-of-pile tests with prototype fuel bundles proved to be satisfactory, 48 additional fuel bundles were loaded in Wolsung reactor (CANDU) in 1984 and 1985, and all of them were discharged without a defect after excellent performance in the power reactor. In 1985, the Korean government decided that KAERI supplies all the fuel necessary for the Wolsung reactor. For the mass production of nuclear fuel bundle, several process equipment, ...

1988-01-01

109

Basic design of alpha aqueous waste treatment process in NUCEF  

Energy Technology Data Exchange (ETDEWEB)

This paper described the basic design of Alpha Aqueous Waste Treatment Process in NUCEF. Since various experiments using the TRU (transuranium) elements are carried out in NUCEF, wastes containing TRU elements arise. The liquid wastes in NUCEF are categorized into three types. Decontamination and volume reduction of the liquid waste mainly of recovery water from acid recovery process which has lowest radioactive concentration is the most important task, because the arising rate of the waste is large. The major function of the Alpha Aqueous Waste Treatment Process is to decontaminate the radioactive concentration below the level which is allowed to discharge into sea. Prior the process design of this facility, the followings are evaluated:property and arising rate of the liquid waste, room space to install and licensing condition. Considering varieties of liquid wastes and their large volume, the very high decontamination factor was proposed by ...

1996-11-01

110

High-Rate Anaerobic Treatment of Wastewater at Low Temperatures  

UK PubMed Central (United Kingdom)

Anaerobic treatment of a volatile fatty acid (VFA) mixture was investigated under psychrophilic (3 to 8°C) conditions in two laboratory-scale expanded granular sludge bed reactor stages in series....Full Text Available

1999-04-01

111

HIGH-RATE DISINFECTION OF COMBINED SEWER OVERFLOW  

Science.gov (United States)

Wet-weather flow (WWF), including combined-sewer overflow (CSO, sanitary-sewer overflow, and stormwater (SW), is a significant contributor of microbial contamination to surface water and ground water. By using effective wastewater or SW disinfection, introduction of pathogen con...

112

Electrochemical treatment of olive oil mill wastewater  

Energy Technology Data Exchange (ETDEWEB)

The possibility of oxidizing at a PbO{sub 2} anode the phenols and polyphenols, present in the olive oil mill wastewater, has been studied as a pre-treatment for the submission of such wastewater to the traditional biological treatments. The results obtained operating at current densities ranging 500 to 2000 A/m{sup 2} show that it is possible to reduce the concentration of the phenolic components, which interfere with the biological treatments, down to low values without decreasing too much the total organic content of the wastewater. [Italian] E' stata studiata la possibilita' di ossidare anodicamente i componenti fenolici delle acque reflue di frantoio, quale pretrattamento delle stesse prima del loro invio ai processi di trattamento biologico. I risultati ottenuti impiegando PbO{sub 2} quale materiale anodico e operando con densita' di corrente comprese tra 500 e 2000 A/m{sup 2} mostrano come ...

2001-04-01

113

Ammonium and Nitrate Uptake by the Floating Plant Landoltia punctata  

UK PubMed Central (United Kingdom)

Background and AimsPlants from the family Lemnaceae are widely used in ecological engineering projects to purify wastewater and eutrophic water bodies. However, the biology of nutrient...Full Text Available

2007-02-01

114

13C-NMR Assessment of the Pattern of Organic Matter Transformation during Domestic Wastewater Treatment by Autothermal Aerobic Digestion (ATAD)  

UK PubMed Central (United Kingdom)

The pattern of biodegradation and the chemical changes occurring in the macromolecular fraction of domestic sludge during autothermal thermophilic aerobic digestion (ATAD) was monitored and characterised...Full Text Available

2009-08-01

115

Wastewater treatment of industrial effluent using activated dolomite adsorption  

Environmental Research Database

SummaryInitial results from the use of activated dolomite from QUESTOR project L1 have proved extremely encouraging in terms of metallic ion (also phosphate, nitrate and dye) removal from wastewater, with capacities in some instances in excess of commercially available activated carbons.This new project involves investigating actual plant effluent in laboratory scale columns and the design of a pilot scale rig for on site trials. The project also involves investigating disposal options and an economic [continued...

2007-01-01

116

The use of treated wastewater for chemlali olive tree irrigation: effects on soil properties, growth and oil quality  

Energy Technology Data Exchange (ETDEWEB)

Olive tree (Olea european L.) cultivation, the major tree crops in Mediterranean countries is being extended to irrigated lands. However, the limited water availability, the severe climatic conditions and the increased need for good water quality for urban and industrial sector uses are leading to the urgent use of less water qualities (brackish water and recycled wastewater) for olive tree irrigation. The aim of this work was to asses the effects of long term irrigation with treated waste water (TWW) on the soil chemical properties, on olive tree growth and on oil quality characteristics. (Author)

2009-07-01

117

Magnetic separation of antibiotics by electrochemical magnetic seeding  

Energy Technology Data Exchange (ETDEWEB)

Magnetic separation of several classes of antibiotics was investigated using electrochemical magnetic seeding. Electrocoagulation with a sacrificial anode followed by addition of magnetite particles was applied for the magnetic seeding of antibiotics. With electrochemical magnetic seeding using an iron anode, tetracycline antibiotics (oxytetracycline, chlortetracycline, doxycycline and tetracycline) and cephalosporin antibiotic (cefdinir) were rapidly removed from synthetic wastewater by magnetic separation using a neodymium magnet. Iron and aluminium anodes were suitable for magnetic seeding of the antibiotics. The results indicated that the ability of antibiotics to form strong complex with iron and aluminium allowed the higher removal by magnetic separation. This method would be appropriate for rapid treatment of antibiotics in wastewater.

2009-03-01

118

Evaluation of wastewater treatment requirements for thermochemical biomass liquefaction  

Science.gov (United States)

Biomass can provide a substantial energy source. Liquids are preferred for use as transportation fuels because of their high energy density and handling ease and safety. Liquid fuel production from biomass can be accomplished by any of several different processes including hydrolysis and fermentation of the carbohydrates to alcohol fuels, thermal gasification and synthesis of alcohol or hydrocarbon fuels, direct extraction of biologically produced hydrocarbons such as seed oils or algae lipids, or direct thermochemical conversion of the biomass to liquids and catalytic upgrading to hydrocarbon fuels. This report discusses direct thermochemical conversion to achieve biomass liquefaction and the requirements for wastewater treatment inherent in such processing. 21 refs.

1992-04-01

119

A mathematical model for simulating shallow solar ponds for treatment of industrial wastewater  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a mathematical model to analyze the solar evaporation in a shallow pond in steady state, when the inlet flow rate, concentration, surface area and solar radiation are given. The simultaneous heat and mass transfer mechanisms are considered for quantifying the amount of evaporated water to the atmosphere and the actual absorbed heat by wastewater is calculated to obtain the bottom temperature of water pond. The heat losses to air by radiation and convection mechanisms are considered and the heat transmission across the water film is evaluated by the forced convection mechanism. 6 refs., 5 figs., 1 tab.

1996-12-31

120

The Role of Electronegative Impurities in Ozone Generation by High Pressure Discharges  

International Nuclear Information System (INIS)

The high pressure discharges (pulsed or D C corona, barrier, gliding and the others), have been studied both experimentally and theoretically as sources of low temperature plasma for pollution control technologies. The potential of electrical discharge methods has been demonstrated for the decomposition of many types of VOC. The air or oxygen are used as a feed gas in which pollutant is diluted. The ozone production in air or oxygen in such discharges is also discussed

1999-07-11

121

State of macroparticles in the plasma of beam-plasma discharge  

International Nuclear Information System (INIS)

... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,

2006-09-11

124

Partial discharge in liquid nitrogen  

Science.gov (United States)

Results are presented of experiments on partial discharge in liquid nitrogen, including insulation breakdown characteristics of liquid nitrogen, partial discharge characteristics of composite insulation systems, lifetime of polymer films, impulse breakdown of polymer films in liquid nitrogen, etc. The partial discharge characteristics of liquid nitrogen are examined with increasing liquid-nitrogen pressure. It is concluded that a composite insulation structure of polymer film and liquid nitrogen can be used as effective electrical insulators at cryogenic temperatures.

1976-01-01

126

Modified Helium microwave-induced plasma discharge chamber  

International Nuclear Information System (INIS)

... Mohamed, MM Medical Research Institute (Egypt) Ghatass, ZF Institute of

1999-04-01

128

Dielectric barrier discharge using corona-modified silicone rubber  

Science.gov (United States)

Results from scanning electron microscopy, Fourier transform infrared spectroscopy and the measurement of thermally stimulated current show that a high density of the physical defects and the chemical defects are introduced into the surface of the silicone rubber plates after they are treated by corona discharge plasma. These defects behave electrically as shallow electron traps, leading to the formation of a uniform discharge in air at higher pressure when the corona-modified silicone rubber is used in dielectric barrier discharge.

2008-10-01

133

University of Central Lancashire - Facilities  

Wastenet

...specialised laboratories for pharmaceutics, tissue culture and molecular biology Excellent Laboratory Facilities Tissue Culture Facilities Molecular Biology Laboratory ...

134

Research on Nanosecond Pulse Corona Discharge Attenuation  

Science.gov (United States)

A line-to-plate reactor was set-up in the experimental study on the application of nanosecond pulsed corona discharge plasma technology in environmental pollution control. Investigation on the attenuation and distortion of the amplitude of the pulse wave front and the discharge image as well as the waveform along the corona wire was conducted. The results show that the wave front decreases sharply during the corona discharge along the corona wire. The higher the amplitude of the applied pulse is, the more the amplitude of the wave front decreased. The wave attenuation responds in a lower corona discharge inversely. To get a higher efficiency of the line-to-plate reactor a sharp attenuation of the corona has to be considered in practical design.

2007-12-01

135

Optogalvanic isotope enrichment of Cu ions in Cu-Ne positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

The isotopic enrichment of copper ions in a positive column Cu-Nu discharge using optogalvanic excitation is analyzed with a rate equation model With excitation at 510.6 nm, the fraction of the ions belonging to the 63-amu isotope of copper is enriched relative to the neutral abundance. Enrichment as large as 10% is calculated when the initial abundance of the neutral isotope is small (< or =0.1) and the discharge current density is large (> or =75 mA/cm/sup 2/). The degree of enrichment is examined as a function of the initial abundance, discharge current, the rate of charge exchange, and the diameter of the discharge tube.

1983-07-01

136

Method for limiting scram discharge water  

International Nuclear Information System (INIS)

Object: To limit the discharge amount of reactor water in a primary system at the time of scram to prevent excessive outflow of reactor water outside the system. Structure: A signal from an upper limit position indicator detects the fact that control rods are completely inserted when the reactor is urgently stopped and the detection signal causes a valve in an outflow line of the discharge water from a control rod driving mechanism to be closed to limit the amount of discharge flown into the scram discharge vessel, thus preventing outflow of reactor water in the primary system after the scram has been initiated. (Kamimura, M.).

137

Lower Flathead System Fisheries Study, Executive Summary, Volume I, 1983-1987 Final Report.  

Energy Technology Data Exchange (ETDEWEB)

This Executive Summary, Volume I, of the lower Flathead System Fisheries Study Final Report, was prepared to provide a study overview for persons who are not fisheries scientists. The contents provide an introduction to the study and its objectives, a short description of the study area, a discussion of the major findings and conclusions of the study, and the description of fisheries management alternatives available to managers of the lower Flathead system. Technical reports were prepared for those portions of the study dealing with the lower Flathead River and its tributaries, Volume II, and the South Bay of Flathead Lake, Volume III. The annual hydrographic regime of the Flathead system, consisting of upper rivers, lake and lower river, has been modified by the construction and operation of two major hydroelectric facilities, Hungry Horse Dam on the south fork Flathead River and Kerr Dam at the outlet of Flathead Lake. The modified hydrographic regime has ...

1988-06-01

138

FY 2000 Feasibility study on the environmentally-friendly coal utilization systems as part of the international project for coal utilization measures. Feasibility study on supporting introduction of the environmentally-friendly coal utilization systems in Vietnam (Model project for introduction of advanced coal preparation systems); 2000 nendo kokusai sekitan riyo taisaku jigyo chosa hokokusho. Kankyo chowagata sekitan riyo system kanosei chosa jigyo Vietnam ni okeru kankyo chowagata sekitan riyo system donyu shien jigyo (kodo sentan system donyu model jigyo kanosei chosa jigyo)  

Energy Technology Data Exchange (ETDEWEB)

The feasibility study was conducted on a model project in Vietnam, aimed at solving the environmental pollution problems resulting from use of coal by demonstrating and disseminating the Japan's environmental technologies in the Southeast Asian countries. The feasibility study was conducted for the Cua Ong Coal Preparation Enterprise, which has the largest coal preparation capacity in Vietnam and port facilities. It is treating raw coal from 10 coal mines for classification and preparation, and shipping coal of various types that meet the standards for domestic use and export. The survey results point out that unrecovered coal remains in waste water discharged from the coal preparation plants to pollute the sea area, and that quantity of the refuse increases because of the unrecovered coal it contains. The environmental technologies needed to introduce include modification to variable wave pattern type jigging separator, refuse height ...

2001-06-01

139

National Ignition Facility Incorporates P2/E2 in Aqueous Parts Cleaning of Optics Hardware  

Energy Technology Data Exchange (ETDEWEB)

When completed, Lawrence Livermore National Laboratory's (LLNL) National Ignition Facility (NIF) will be the world's largest laser with experimental capabilities applicable to stockpile stewardship, energy research, science and astrophysics. As construction of the conventional facilities nears completion, operations supporting the installation of specialized laser equipment have come online. Playing a critical role in the precision cleaning of mechanical parts from the NIF beamline are three pieces of aqueous cleaning equipment. Housed in the Optics Assembly Building (OAB), adjacent to NIF's laser bay, are the large mechanical parts gross cleaner (LMPGC), the large mechanical parts precision cleaner (LMPPC), and the small mechanical parts gross and precision cleaner (SMPGPC). These aqueous units, designed and built by Sonic Systems, Inc., of Newtown, Pennsylvania, not only accommodate parts that vary greatly in size, ...

2001-07-27

140

Ultrasound and airflow induced thermal instability suppression of DC corona discharge: an experimental study  

International Nuclear Information System (INIS)

The effect of ultrasound waves, airflow and combined ultrasound with the airflow on the thermal instability suppression of a hollow needle-to-plate electrical discharge was studied experimentally. To evaluate the thermal instability suppression we used the V-A characteristics of the discharge in stationary air, with ultrasound applied in stationary air, and finally when the airflow was supplied into the discharge through the needle without and with ultrasound application. To illustrate the effect of ultrasound, airflow and combined ultrasound with airflow on the discharge thermal instability suppression we also studied the discharge ozone production. We found that in stationary air the application of ultrasound only slightly suppresses thermal instability. A substantial increase of ozone generation was not detected. Application of the airflow through the needle suppressed ...

2006-02-01

141

A study on the management of spent fuel storage capacity in South Korea  

International Nuclear Information System (INIS)

The saturation of South Korea's at-reactor (AR) spent fuel storage pools will create a necessity for additional spent fuel storage capacity. Because the South Korean government has the plan to increase the number of nuclear power plants from 20 units (end of 2005) to 27 units by 2015, the increase of spent nuclear fuel generation will be accelerated. Because there is no clear national plan for spent nuclear fuel storage and disposal, the utility company (Korea Hydraulic Nuclear Power company) is planning to construct a spent fuel storage facility with 11 000 tHM capacity for Pressurised Water Reactor (PWR). This study is intended to predict the maximum allowable periods when the storage facility will be fully occupied with respect to the already fixed re-racking plan of spent fuel storage pools and construction of new nuclear power plants. The result from this study will be used as fundamental data for an efficient management of the spent fuel ...

2006-06-19

142

Ozone generation in a negative corona discharge fed with N_2O and O_2  

International Nuclear Information System (INIS)

Ozone production in a negative corona discharge has been studied experimentally at atmospheric pressure in mixtures of N_2O+O_2 at ambient temperature. Ozone formation was found to be dramatically reduced with increase in the content of N_2O in the mixture. The reaction of O("1D) with nitrous oxide is the most likely process reducing the rate of ozone generation. A considerable decrease in the mean discharge current at a constant voltage was also observed with increasing content of nitrous oxide in the mixture and is attributed to the formation of anions in the discharge. The low values of the calculated mobility of negative charge carriers in the drift region of the discharge is caused by the formation of O"- #centre dot# (N_2O)_n and NO"-#centre dot#(N_2O)_n cluster anions in the drift region of the negative corona discharge.

2004-04-07

143

Fates of dissolved and particulate materials from the Mississippi river immediately after discharge into the northern Gulf of Mexico, USA, during a period of low wind stress  

British Library Electronic Table of Contents (United Kingdom)

In June 2003, we conducted a two-part field exercise to examine biogeochemical characteristics of water in the lower Mississippi river during the 4 days prior to discharge and in the Mississippi river plume over 2 days after discharge. Here we describe the fates of materials immediately after their discharge through Southwest Pass of the Mississippi delta into the northern Gulf of Mexico. Changes in surface water properties immediately after discharge were much larger and more rapid than changes prior to discharge. Total suspended matter (TSM) declined, probably due to sinking, dissolved macronutrients were rapidly diminished by mixing and biological uptake, and phytoplankton populations increased dramatically, and then declined. This decline appeared to begin at salinities of approximatel...

2008-01-01

144

A finite element based model for electrochemical discharge machining in discharge regime  

British Library Electronic Table of Contents (United Kingdom)

Electrochemical discharge machining (ECDM) is a promising hybrid process for high-performance machining of non-conductive glass. ECDM drilling has been found to have different characteristics and material removal mechanisms in discharge regime (less than 300??m in depth) and hydrodynamic regime (more than 300??m in depth); however, these regimes are never separately modeled in existing ECDM models, which leads to large prediction error, especially at low applied voltages and high machining depths. Until now, no model is particularly designed for discharge regime, where most material is removed. In this paper, a finite element based model for ECDM drilling in discharge regime is presented. Material removal subjected to a single spark was simulated using finite element method. The drilling d...

2011-01-01

145

Decomissioning Strategies for Facilities Using Radioactive Material  

CERN Document Server

Decomissioning Strategies for Facilities Using Radioactive Material

2007-01-01

146

Phosphorous adsorption and precipitation in a permeable reactive wall: Applications for wastewater disposal systems  

Energy Technology Data Exchange (ETDEWEB)

A permeable reactive mixture has been developed using low cost, readily available materials that is capable of providing effective, long-term phosphorous treatment in areas impacted by on-land wastewater disposal. The reactive mixture creates a geochemical environment suitable for P-attenuation by both adsorption and precipitation reactions. Potential benefits include significant reductions in phosphorous loading to receiving groundwater and surface water systems, and the accumulation of P-mass in a finite and accessible volume of material. The mixture may be applied as a component within surface treatment systems or in subsurface applications such as horizontal or vertical permeable reactive walls. The mixture averaged > 90% treatment efficiency over 3.6 years of continuous-flow laboratory column experiments. The mixture was further evaluated at the pilot-scale to treat municipal wastewater, and the field-scale to treat a well-characterized ...

1997-12-31

147

Evaluating the cytotoxicity of palladium/magnetite nano-catalysts intended for wastewater treatment  

International Nuclear Information System (INIS)

Palladium/magnetite nanoparticulate catalysts were developed for efficient elimination of halogenated organic pollutants from contaminated wastewater. Particle recovery from treated water can be ensured via magnetic separation. However, in worst-case scenarios, this catalyst removal step might fail, leading to particle release into the environment. Therefore, a toxicological study was conducted to investigate the impact of both pure magnetite and palladium/magnetite nanoparticle exposure upon human skin (HaCaT) and human colon (CaCo-2) cell lines and a cell line from rainbow trout gills (RTgill-W1). To quantify cell viability after particle exposure, three endpoints were examined for all tested cell lines. Additionally, the formation of reactive oxygen species was studied for the human cells. The results showed only minor effects of the particles on the tested cell systems and support the assumption that palladium/magnetite nano-catalysts can be implemented for a ...

2010-01-01

148

Development of a Novel Bioelectrochemical Membrane Reactor for Wastewater Treatment.  

Science.gov (United States)

A novel bioelectrochemical membrane reactor (BEMR), which takes advantage of a membrane bioreactor (MBR) and microbial fuel cells (MFC), is developed for wastewater treatment and energy recovery. In this system, stainless steel mesh with biofilm formed on it serves as both the cathode and the filtration material. Oxygen reduction reactions are effectively catalyzed by the microorganisms attached on the mesh. The effluent turbidity from the BEMR system was low during most of the operation period, and the chemical oxygen demand and NH(4)(+)-N removal efficiencies averaged 92.4% and 95.6%, respectively. With an increase in hydraulic retention time and a decrease in loading rate, the system performance was enhanced. In this BEMR process, a maximum power density of 4.35 W/m(3) and a current density of 18.32 A/m(3) were obtained at a hydraulic retention time of 150 min and external resister of 100 ?. The Coulombic efficiency was 8.2%. Though the power density and current ...

2011-10-01

149

Development and application of bio-sensor. Production of ammonia sensor  

Energy Technology Data Exchange (ETDEWEB)

The objectives of this study are to make a biosensor on a trial basis which can instantaneously measure the nitrogen in wastewater, and to develop a wastewater treatment system which is capable of on-line measurement and controlling. The system provides easier operational control relating to such a high efficient treatment as the removal of nitrogen content in wastewater, serving as a solution to the eutrophication problem. It can be applied also to the analysis of fertilizer components for agriculture. Ammonia oxidizing bacteria were immobilized with cellulose acetate film, which is mounted on a diaphragm type oxygen electrode to make a sensor, and its responsibility was studied. The gradient is slow in high concentration but sharp in low concentration, and it seems possible to use it for the measurement for less than 20 ppm nitrogen concentration. The dependence of the sensor including electrodes and activity of bacteria ...

1989-08-01

150

Anaerobic treatment of wastewater from a food-manufacturing plant with a low concentration of organic matter and regeneration of usable pure water  

Energy Technology Data Exchange (ETDEWEB)

Wastewater from a food-manufacturing plant with a low concentration of organic matter was treated at 37 centigrade in an anaerobic fluidized-bed reactor or in an upflow anaerobic sludge blanket. As the influent TOC (total organic carbon) concentration decreased, the TOC removal efficiency in these reactors decreased from 85% to 65%. The concentration of suspended solids in the effluent could be reduced to 20 mg/l, which corresponded to 7% of that in the influent. The effluent from both reactors was treated aerobically in a fixed-bed reactor. The TOC concentration and optical density of effluent from the aerobic treatment were reduced to 5 mg/l and 0.005, respectively. When the effluent treated anaerobically or aerobically was passed over an activated carbon column, the effluent TOC concentration was reduced to 2 to 3 mg/l. The conductivity in raw wastewater was remarkably reduced on an ion-exchange resin column. Ultra-pure water for industrial ...

1994-03-25

151

Anaerobic digestion of olive mill wastewaters  

Energy Technology Data Exchange (ETDEWEB)

Anaerobic treatment of olive oil mill wastewaters (COD up to 220 kg/cubic m) is feasible, and the most promising results were obtained on UASB reactors, both at laboratory and pilot scale (tank capacity 15 litres and 5 cubic m), fed on diluted waste (COD = 13-18 kg/cubic m). Volumetric loading rates ranging from 16-21.5 kg COD/cubic m/day and 70% removal efficiencies were obtained with these digesters. Start-up of UASB reactors fed on olive oil mill waste is a delicate step which still has to be fully controlled and optimized. The best results were obtained by starting with very diluted waste (COD = 5 kg/cubic m). Granulation of the sludge, as achieved in Dutch UASB digesters fed on sugar beet wastewaters, was not obtained, but, even so, the settleability of the sludge was very good. 22 references.

1984-01-01

152

Generators of nonequilibrium low-temperature plasma  

Energy Technology Data Exchange (ETDEWEB)

Results are described of a study and of the characteristics of sources of a non-equilibrium gas-discharge plasma. The plasma generators considered include glow, high frequency, and arc discharge generators. Thermodynamic, ionic, and electronic processes occurring in the plasmas are evaluated.

1988-06-01

153

Formation of the electret state of polymers in a gas discharge plasma  

Science.gov (United States)

The present article studies the electret state of polymers when moving through an alternating-current corona discharge plasma and investigates means for the determination of the transition of the polymeric material from the initial state of the electret when the corona-displaying voltage is increased.

1983-02-01

154

Electrical Discharge Machining (EDM) Gun Barrel Bore and Rifling Feasibility Study.  

Science.gov (United States)

A 12-month program was conducted to advance the technology of the Electrical Discharge Machining (EDM) process to be applicable to the stringent requirements of gun barrel boring and rifling. The type of barrels employed in the test were .220 swift gun ba...

1974-01-01

155

Cost-Effectiveness Analysis of Proposed Effluent Limitations Guidelines and Standards for the Pesticide Manufacturing Industry.  

Science.gov (United States)

The report analyzes the cost-effectiveness of two alternative regulatory options: A Treated Discharge Option and a Zero Discharge Option. The report compares the total annualized cost incurred for each of the two regulatory options to the corresponding ef...

1992-01-01

156

Analysis of the relation between "3H concentrations in sea water of West Daya Bay and GNP's liquid "3H discharges  

International Nuclear Information System (INIS)

Through the analysis of the relations between "3H monitoring results of sea water in West Daya Bay carried out by Guangdong Environmental Radiation Research and Monitoring Center (GERC) from 1994 to 2000 and the quantity of liquid "3H discharges made by Guangdong Nuclear Power Station (GNPS), the function has been found by fitting to describe the relation between "3H average concentrations (hereafter as to average concentration or concentration) for all sampling points at the same time and the quantity of liquid "3H discharges. "3H instantaneous concentrations or yearly average concentration in West Daya Bay can be estimated conveniently by using this function corresponding to either actual discharges or supposed discharges (the way for hydrodynamic calculation) from the GNPS's yearly "3H liquid discharge. The results have shown that the general influences both actual ...

2001-11-01

157

A device for controlling the degree of discharge intensity of a storage battery  

Energy Technology Data Exchange (ETDEWEB)

The device is designed for automatic testing of the degree of discharge of tractive storage batteries (AB) for electric loaders, electric cars and electric ore locomotives. The basic electrical schematic of the device is cited.

1983-01-01

158

Transverse glow discharges in supersonic air and methane flows  

British Library Electronic Table of Contents (United Kingdom)

Transverse glow discharges in supersonic air and methane flows are studied both experimentally and theoretically. The experiments show that a diffuse volume discharge filling the whole cross section of the flow can easily be initiated in air, whereas a diffuse discharge in a methane flow shows a tendency to transition into a constricted mode. The electron transport coefficients (mobility and drift velocity) and the kinetic coefficients (such as collisional excitation rates of the vibrational levels of a methane molecule, as well as dissociation and ionization rates) are calculated by numerically solving the Boltzmann equation for the electron energy distribution function. The calculated coefficients are used to estimate the parameters of the plasma and the electric field in the positive co...

2006-01-01

161

Phase formation in gas-phase combustion and pyrolysis reactions under spark and radio-frequency discharge conditions  

British Library Electronic Table of Contents (United Kingdom)

Doped ultrafine silicon dioxide powder with a narrow particle size distribution was obtained by RF discharge-stimulated dichlorosilane (SiH2C) oxidation at a low pressure using isobutylene as the combustion inhibitor and chromium hexacarbonyl (Cr(CO)6) as the dopant. The formation and morphology of the ultrafine particles are governed by the parameters of the RF discharge and by the chemical mechanism of the combustion reaction yielding the aerosol. Submicron-sized filamentous carbon structures can be obtained by isobutylene decomposition under spark discharge conditions in the presence of a molybdenum metal catalyst.

2009-01-01

162

Pathogenic and nonpathogenic Acanthamoeba spp. in thermally polluted discharges and surface waters  

International Nuclear Information System (INIS)

During spring and autumn, the total number of amoebae and the number of acanthamoeba species able to grow at 37 degrees C were determined in six thermally polluted factory discharges and the surrounding surface waters. The isolated Acanthamoeba strains were studied for growth in axenic medium, cytopathic effect in Vito cell cultures, and virulence in mice. Although more amoebae were isolated in autumn, the number of Acanthamoeba species was lower than in spring, when the percent of pathogenic strains among the isolates was highest. Higher concentrations of amoebae were found in warm discharges, and more virulent strains occurred in thermal discharges than in surface waters.

164

Effect of discharge voltage on an ion sheath formed at a grid in a multi-dipole discharge plasma  

International Nuclear Information System (INIS)

It is experimentally demonstrated that a relatively strong ion-rich sheath formed at a fixed negative bias of the grid can be changed to a rather weak ion sheath (sheath potential weakly retards electrons) only by increasing the discharge voltage in the system. At sufficiently high negative grid bias, an increase of discharge voltage enhances the ion collection current at the grid. An explanation is put forward in support of this experimental observation. A slight density enhancement with a fall in plasma electron temperature is also observed with the increasing negative grid bias. (authors)

2008-03-01

166

CAPACITOR DISCHARGE METAL FORMING  

Science.gov (United States)

... Report Date : JUL 1961. Pagination or Media Count : 39. Abstract : Open-ende Terms: Electrohydraulic forming, Magnetic forming. ...

1961-07-01

167

An overview of standards concerning unwanted electrostatic discharges  

British Library Electronic Table of Contents (United Kingdom)

For users and manufacturers affected by unwanted electrostatic discharges, the publication of standards concerning the control of such discharges is a great improvement and helps to prevent unwanted electrostatic discharges in potentially explosive atmospheres as well as around electrostatically sensitive devices. There are, for instance, handbook-like documents giving recommendations to help set up effective electrostatic suppressing measures and programs. Another group of standards focuses on certain products and processes and is, thus, more specific. A third group deals with test methods and specifications to help manufacturers develop products that are safe. It also helps in comparisons with other products and thus meets the customer's real needs. To assist manufacturers and customers ...

2009-01-01

168

Ozonation kinetics of phenolic acids present in wastewaters from olive oil mills  

Energy Technology Data Exchange (ETDEWEB)

A kinetic study of the degradation by ozone of eight phenolic acids present in wastewaters from olive oil mills has been performed by using a competition kinetic method. The selected phenolic acids are: caffeic, p-coumaric, syringic, vanillic, 3,4,5-trimethoxybenzoic, veratric, p-hydroxy-benzoic, and protocatechuic. The influence of the operating variables (temperature, pH, and ozone partial pressure in the gas stream) is established, and the stoichiometric ratios for the individual direct reactions between ozone and each acid are determined. Once the reaction rate constants are evaluated, they are correlated as a function of temperature and pH into kinetic expressions which are provided for every phenolic acid. The global process occurs in the fast and pseudo-first-order kinetic regime of absorption, a condition required by the competition model to be used.

1997-03-01

169

Dye Removal, Energy Consumption and Operating Cost of Electrocoagulation of Textile Wastewater as a Clean Process  

British Library Electronic Table of Contents (United Kingdom)

Abstract In this research, the efficiency of electrocoagulation treatment process using aluminum electrodes to treat synthetic wastewater containing Reactive Red198 (RR198) was studied. The effects of parameters such as voltage, time of reaction, electrode connection mode, initial dye concentration, electrolyte concentration, and inter electrode distance on dye removal efficiency were investigated. In addition, electrical energy consumption, electrode consumption, and operating cost at optimum condition have been investigated. The results showed that dye and chemical oxygen demand removals were 98.6 and 84%, respectively. Electrode consumption, energy consumption and operating cost were 0.052-kg/m3, 1.303-kWh/m3 and 0.256-US$/m3, respectively. Dye removal kinetic followed first order kinet...

2011-01-01

170

The role of plasma potential in d.c. glow discharge conditions in nitriding process of EJ961 steel  

International Nuclear Information System (INIS)

Results of researches on nitriding process of EJ961 steel are presented in this work. This steel was subjected to nitriding both on the cathode and on the isolated from cathode and anode substrate, that is at so called potential of glow discharged plasma. Nitriding processes were performed using device for glow discharge treatments with cooled anode. (author)

2002-09-18

171

TEM-investigations of erosion craters caused by electrical discharge; TEM-Untersuchungen an Erosionskratern, die durch elektrische Entladungen erzeugt werden  

Energy Technology Data Exchange (ETDEWEB)

Craters were produced in the surface of a Pt-specimen by plasma discharge. Using a Focussed Ion Beam (FIB), TEM-foils of the cross section of the craters were prepared in order to examine the microstructural changes occurring as a result of the discharge impact. The molten material pushed to the edge of the craters was able to be identified. The grains beneath the craters reached the surface of the crater by a mechanism of epitaxial growth. (orig.)

2005-11-01

172

A kinetic study of ozone and nitric oxides in dielectric barrier discharges for O_2/NO_x mixtures  

International Nuclear Information System (INIS)

A simple model is described to simulate kinetic processes in dielectric barrier discharges for O_2/NO_x mixtures. A threshold of ozone production found experimentally is confirmed by the calculations of this modeling, and the underlying chemical reaction mechanisms are discussed. It is also found that the effects of diffusion processes in the period of the lifetime of O atoms are not important to micro-discharge channels with a large radius, i.e. larger than 150 #mu#m

2002-04-01

173

The Formation of the Low-sized High Density Plasma Structures in the Self-maintained Plasma-beam Discharge  

International Nuclear Information System (INIS)

The opportunity of use self-maintained plasma-beam discharge in an extended pulsing plasma diode of low pressure for making powerful sources of the soft X-rays is investigated. Conditions of formation of the self-maintained plasma-beam discharge are determined. The mode of making of dense high-temperature plasma on the basis of stannum ions in the discharge is shown. The stannum ions are used as a working element of a radiation sources at pulsing power of electron beam P?10...100 MW. Results of the examination on formation of the dense (np?1016 cm3), small sizes (le?100 eV in conditions of working material evaporation from the anode are given. The total contribution of energy to the discharge has made W < 20 J.

2006-01-01

174

Specific features of the current-voltage characteristics of diffuse glow discharges in Ar:N2 mixtures  

British Library Electronic Table of Contents (United Kingdom)

The characteristics of diffuse glow discharges in pure argon and the Ar + 1%N2 mixture at pressures of 2?80 Torr were studied experimentally and numerically. The discharge operated in a molybdenumglass tube with an inner diameter of 2.8 cm and interelectrode distance of 75 cm. The current-voltage characteristic of the discharge and the populations of the N2(B3? g ) and N2(C3? u ) states were measured. It is shown that, at relatively low pressures (P 15 Torr), the current-voltage characteristic of a discharge in the mixture lies lower than that in pure argon. As the pressure increases, the effect of the reduction in the discha...

2010-01-01

175

Numerical simulation of a pulsed corona discharge plasma  

Science.gov (United States)

In this paper we study theoretically a pulsed corona discharge plasma in air at atmospheric pressure. A self consistent one-dimensional model, using a flux-corrected transport numerical scheme, is presented to achieve it. The charged particle kinetics in this model are described by one-dimensional continuity equations coupled with Poisson's equations. The spatio-temporal local field, charge density variations and the velocity profile of an ionizing front are calculated to describe the dynamical behavior of corona discharge plasmas. The simulation results of a wire-in-cylinder corona discharge plasma explain the physical mechanisms of discharge processes. These results may also be apply to obtain the optimizing parameters for designing the plasma reactor.

2001-10-01

176

Liquid radioactive waste discharges from B plant to cribs  

Energy Technology Data Exchange (ETDEWEB)

This engineering report compiles information on types and quantities of liquid waste discharged from B-Plant directly to cribs, ditches, reverse wells, etc., that are associated with B-Plant. Waste discharges to these cribs via overflow form 241-B, 241-BX, and 241-BY tank farms, and waste discharged to these cribs from sources other than B-Plant are discussed.Discharges from B-Plant to other cribs, unplanned releases, or waste remaining in tanks are not included in the report. Waste stream composition information is used to predict quantities of individual chemicals sent to cribs. This provides an accurate mass balance of waste streams from B-Plant to these cribs. These predictions are compared with known crib inventories as a verification of the process.

1996-05-29

177

Erosive radially-slotted discharge in sheet current mode  

CERN Document Server

New non-stationary non-contracted form of the erosive radially-slotted discharge as a thin round sheet with the current of the azimuth direction have been discovered, its existence beings stipulated by a radial transport-wave fluxes. Characteristic features of this discharge is self-confinement of the discharge current magnitude, corresponding decrease of the current pulse duration and occurrence of an energy and substance ejection with rather unusual properties. Measurements of kinetics of the discharge current, the plasma radiation intensity and an electrical probe signal, as well as the transmission electron microscope investigations of characteristic aerodisperse aggregates arising the erosive phase, have been carried out. The probe signal duration was about 10 times greater than that of the current; its kinetics was complicated suggesting existence in the slot of two components with fundamentally ...

2001-01-01

178

Electrostatic discharge effects on EBW detonators  

Science.gov (United States)

With appropriate circuit resistance and inductance and sufficient stored energy, discharging a charged human body or component through an exploding bridgewire (EBW) detonator may cause the detonator to function or may damage the detonator. We have studied the effects of electrostatic discharge (ESD) on a number of exploding bridgewire detonators which were subjected to discharges which passed directly through the bridgewires (pin-to-pin), as well as discharges which passed from the bridge to the metal case of the detonator (pin-to-case). We have performed calculations to determine the values of inductance and resistance for which burst and melt may occur for given ESD sources, using a phenomenological model of bridgewire burst in a computer code called FIRESET. Bridge melt was computed using the same computer code, but using experimental values of bridge resistivity and specific heat up to melt. 13 ...

1991-04-01

179

Effects of Nitrogen Gas Ratio on Nitride Layer and Microhardness of Tool Steel(SKH51) in Plasma Nitriding  

Energy Technology Data Exchange (ETDEWEB)

Pulsed DC-plasma nitriding has been applied to form nitride layer having only a diffusion layer. The discharge current with the variation of discharge gases is proportional to the intensity of N{sub 2}{sup +} peak in optical emission spectroscopy during the plasma nitriding. The discharge current, microhardness in surface of substrate and depth of nitride layer increased with the ratio of N{sub 2} to H{sub 2} gas in discharge gases. When the ratio of N{sub 2} to H{sub 2} is lower than 60% in the discharge gases, high microhardness value of 1100Hv nitride layer which contains no compound layer has been formed. (author). 20 refs., 6 figs., 1 tab.

2002-06-01

180

Capacity-coupled multidischarge for atmospheric plasma production  

International Nuclear Information System (INIS)

We propose a method of plasma production by capacity-coupled multidischarge (CCMD) at atmospheric pressure. The discharge gaps in the CCMD consist of a common electrode and a number of compact electrodes (CCE) which are directly coupled with small capacitors for quenching the discharge. A simple CCE structure is provided by a cylindrical capacitor, the inner conductor of which is used as a gap electrode. A short pulse discharge is observed to appear homogeneously at each CCE. A charge transfer for the single-pulsed discharge is 10-100 times as large as that of the conventional dielectric barrier discharge. A high efficiency of ozone production has been confirmed in the CCMD using O_2 gas. A device configuration of the CCMD is quite flexible with respect to its geometrical shape and size. The CCMD could be used to produce plasmas for various kinds of industrial applications at ...

2003-12-29

181

Far-field model of the regional influence of effluent plumes from ocean thermal energy conversion (OTEC) plants  

Science.gov (United States)

Ocean thermal energy conversion (OTEC) plants discharge large volumes of cold water into the upper ocean. A three-dimensional, limited-area model was developed to investigate the regional influence of the far-field effluent plume created by the negatively buoyant discharge. The model was applied to discharges from a 40-MW/sub e/ OTEC plant into coastal waters characterized by various ambient ocean conditions. A typical ambient temperature structure and nutrient distribution, as well as the behavior of the effluent plume itself, were strongly modified by the discharge-induced circulation. Although temperature perturbations in the plume were small, upward entrainment of nutrients from below the thermocline was significant. The regional influence of discharges from an 80-MW/sub e/ OTEC plant, the interactions between the discharges from two adjacent 40-MW/sub e/ ...

1985-07-01

182

Electrical breakdown at low pressure in the presence of a weak magnetic field  

Energy Technology Data Exchange (ETDEWEB)

Electron trapping in crossed electric and magnetic fields is an important mechanism by which electrical discharges can develop in low pressure gases. The authors report observations of discharges produced by this mechanism around a spherical anode in two space simulation chambers, namely the Space Plasma Interaction Experiment (SPIE) at the University of Maryland, and the NASA-Lewis B-2 chamber. They have identified two types of discharges in these experiments. In the B-2 chamber, the breakdown takes the form of a runaway dischage with spherical topology, limited only by the ability of the power supply to provide the current. In the SPIE chamber this type of discharge also occurs, in addition to a low current toroidal discharge which is observed at higher magnetic fields. They present measurements of both types of discharge and show how the trapping effect of ...

1990-05-01

183

Efficiency of ozone production by pulsed positive corona discharge in synthetic air  

International Nuclear Information System (INIS)

We have studied the efficiency of ozone production by pulsed positive corona discharge in coaxial wire-cylinder geometry at atmospheric pressure. A corona discharge was generated by short (#approx#150 ns) high voltage pulses applied between a silver coated copper wire anode and stainless steel cylinder cathode in synthetic air. A pyrex probe and Teflon tube was used for collecting discharge products and an ozone concentration was monitored outside of the discharge chamber by a non-dispersive UV absorption technique. The production of ozone was investigated as a function of energy density (10"-"4-3x10"-"1 Wh l"-"1) delivered to the discharge volume by combining the discharge frequency (0.1-10 Hz) and airflow rate (1-32 l min"-"1). From ozone concentration measurements we have evaluated the ozone production, yield and production energy cost. The ozone production ...

2002-06-07

184

Wetlands remediation of gallium arsenide: A case study describing a site-specific exposure assessment  

Energy Technology Data Exchange (ETDEWEB)

Based upon the existing regulatory cleanup criteria, remediation of this wetlands was proposed by the New Jersey Department of Environmental Protection and Energy (NJDEPE). This remedial process would have totally destroyed a thriving Old Field Wetlands. Site-Specific evaluation of the chemicals of potential concern (CPC), remaining source areas, potential environmental fate and transport (EF and T), toxicology (including oral absorption and bioaccumulation) and potential land use scenarios were conducted. It was determined that although the analytical chemistry data reported soil concentrations of arsenic, the compound used by the facility and discharged to the wetlands sediments was in fact gallium arsenide. Secondly, all remaining source areas and hot spots had previously been remediated. Vertical migration to soils had not progressed past a depth of 3 feet and groundwater/surface water did not contain significantly elevated concentrations ...

1994-12-31

185

W-12 valve pit decontamination demonstration  

Energy Technology Data Exchange (ETDEWEB)

Waste tank W-12 is a tank in the ORNL Low-Level Liquid Waste (LLLW) system that collected waste from Building 3525. Because of a leaking flange in the discharge line from W-12 to the evaporator service tank (W-22) and continual inleakage into the tank from an unknown source, W-12 was removed from service to comply with the Federal Facilities Agreement requirement. The initial response was to decontaminate the valve pit between tank W-12 and the evaporator service tank (W-22) to determine if personnel could enter the pit to attempt repair of the leaking flange. Preventing the spread of radioactive contamination from the pit to the environment and to other waste systems was of concern during the decontamination. The drain in the pit goes to the process waste system; therefore, if high-level liquid waste were generated during decontamination activities, it would have to be removed from the pit by means other than the available liquid waste ...

1995-12-01

186

The development of PHWR fuel fabrication in Korea  

International Nuclear Information System (INIS)

Korea Advanced Energy Research Institute (KAERI) started a research project to develop the PHWR (CANDU) nuclear fuel fabrication technology in 1981. Based on the results of the intensive developmental work, several prototype fuel bundles were fabricated and tested in the Hot Test Loop at KAERI continuously in 1983 and 1984. After that, irradiation test and post-irrradiation examination were carried out for two KAERI-made fuel bundles at Chalk River Nuclear Laboratories in Canada in 1984. Since the results of in-pile and out-of-pile tests with prototype fuel bundles proved to be satisfactory, 48 additional fuel bundles were loaded in Wolsung reactor (CANDU) in 1984 and 1985, and all of them were discharged without a defect after excellent performance in the power reactor. In 1985, the Korean government decided that KAERI supplies all the fuel necessary for the Wolsung reactor. For the mass production of nuclear fuel bundle, several process equipment, ...

1987-09-07

187

Terra Nova Environmental effects monitoring program  

Energy Technology Data Exchange (ETDEWEB)

Elements of the environmental effects monitoring program in the Terra Nova oil field, about 350 km east-southeast of St. John's, Newfoundland, are described. This oilfield is being developed using a floating production storage and offloading (FPSO) facility. A total of 24 wells are expected to be drilled through seven subsea templates located in four glory holes to protect them from icebergs. Subsea installations will be linked to the FPSO by trenched flowlines connected to flexible risers. The FPSO will offload to shuttle tankers. First oil is expected in 2001. The environmental effects monitoring program will be conducted annually for the first two years beginning in 2000. Subsequent scheduling will be determined after a review of monitoring data collected during the first three years. Input to the design of the monitoring program was provided by all stakeholders, i. e. owners, local public, government agencies and regional and international experts. A ...

2000-07-01

188

Self-construction of a solar water heater; Calentador solar de agua de auto-construccion  

Energy Technology Data Exchange (ETDEWEB)

In this work a flat receiver of self construction is shown with relatively low cost and easy manufacture, but with a thermal efficiency superior to 40% for applications at temperatures less than 60 degrees Celsius, that allows satisfying international standards in this respect. The heater has been matter of study in open courses distributed in the Universidad Autonoma de la Ciudad de Mexico (UACM) oriented to that the participants construct their own system, in addition to its installation and tests. The obtained results have been excellent. The massive use of efficient solar receivers of self-construction can truly help to the decreasing of the gas discharges of greenhouse effect. [Spanish] En este trabajo se presenta un captador plano de auto construccion con relativamente bajo costo y facil manufactura, pero con un rendimiento termico superior a 40% para aplicaciones a temperatura menos de 60 grados centigrados que le permite satisfacer ...

2009-07-01

189

Plasma dynamics in PF-1000 device under full-scale energy storage: I. Pinch dynamics, shock-wave diffraction, and inertial electrode  

International Nuclear Information System (INIS)

This paper (paper I) presents the first part of results obtained with the PF-1000 facility for the first time at its upper energy limit (?1 MJ). Special attention is paid here to plasma ('pinch') dynamics, which was investigated in relation to its electro-technical and radiation (especially neutron) characteristics with the help of a number of diagnostics, both time-integrated and with nanosecond temporal resolution. In these methods we utilized a Rogowski coil for the routine electro-technical measurements, visual multi-frame and streak cameras, soft x-ray pin-hole multi-frame cameras, PIN-diode assembly and PM tubes with scintillators for soft and hard x-rays as well as for neutron investigations together with a set of activation counters. In particular, the temporal cross correlation of different phenomena taking place during the discharge was investigated. The pinch's longevity appears to be 10-15 times larger than the ideal ...

2007-04-07

190

LLNL explosives handbook: properties of chemical explosives and explosives and explosive simulants  

Energy Technology Data Exchange (ETDEWEB)

This handbook presents information and data for high explosives (HEs) of interest to programs at the Lawrence Livermore National Laboratory (LLNL) and other Department of Energy (DOE) facilities. It is intended to be useful to the scientist or engineer, the novice or expert, who needs to develop a new weapon system, design a physics experiment, or select and/or evaluate an existing explosive. This compilation is limited to production HEs and their components. High explosives are divided into two classes: initial detonating (or primary) and noninitiating (or secondary) explosives. The primary HEs, such as azides and fulminates, are extremely sensitive to ignition by heat, shock, and electrical discharge; ignition leads to high-order detonation of the material - even for milligram quantities. The use of these HEs is therefore limited to squibs and starting materials for low-energy detonators. Because primary explosives have little application at ...

1981-03-16

191

Increased Mercury Bioaccumulation Follows Water Quality Improvement  

International Nuclear Information System (INIS)

Changes in physical and chemical characteristics of aquatic habitats made to reduce or eliminate ecological risks can sometimes have unforeseen consequences. Environmental management activities on the U.S. Dept. of Energy reservation in Oak Ridge, Tennessee,have succeeded in improving water quality in streams impacted by discharges fi-om industrial facilities and waste disposal sites. The diversity and abundance of pollution-sensitive components of the benthic macroinvertebrate communities of three streams improved after new waste treatment systems or remedial actions reduced inputs of various toxic chemicals. Two of the streams were known to be mercury-contaminated from historical spills and waste disposal practices. Waterborne mercury concentrations in the third were typical of uncontaminated systems. In each case, concentrations of mercury in fish, or the apparent biological availability of mercury increased over the period during which ...

192

Field-effect research at the High Voltage Transmission Research Center  

Energy Technology Data Exchange (ETDEWEB)

This report presents information obtained during five different studies of field effects from high voltage transmission lines performed at EPRI's High Voltage Transmission Research Center. The first study is the development of a methodology for the evaluation of the expected frequency of occurrence of specific short-term effects of spark discharges and induced currents caused by overhead high voltage transmission lines. The methodology is divided into the analysis of the expected frequency of occurrence of situations in which induction effects may occur, and the analysis of the expected severity of the effect. The second study is of the electric field in the surface and on the immediate proximity of the strands of stranded conductors used for overhead high voltage lines. In particular, the cases of deformations of stranded conductors, caused by air expansion or by popped out strands, are analyzed for the purpose of determining the conditions for occurrence ...

1991-02-01

193

Feasibility study on the demonstrative test on the hybrid mini hydroelectric power generation technology. 2; Hybrid gata mini suiryoku hatsuden gijutsu ni kakawaru jissho shiken kanosei chosa. 2  

Energy Technology Data Exchange (ETDEWEB)

A study was made for the purpose of electrification of unelectrified zones of the mountainous areas in developing countries using extremely small hydroelectric power facilities. The target for this project is a development of a micro hydroelectric power system with a size of about 5kW, which is estimated regarding that 1 village has 80 houses and each house needs electricity of 60W. In the study, the low-head system using a weir of irrigation channels in Subang pref. of West Java state was selected by the evaluation of access, stability of flow rate, natural conditions, etc. The hydroelectric power plant is of a flow-in method in which water is taken from the left bank and is injected/discharged to the downstream of the left bank. As the hybrid complementary power source, hybrid battery with a two-hour charging time at peak and a capacity of 3.5kWh was considered. When estimating the construction cost of the hybrid micro hydroelectric power ...

1996-03-01

194

Biocide and corrosion inhibition use in the oil and gas industry: Effectiveness and potential environmental impacts  

International Nuclear Information System (INIS)

Treatment chemicals are used in all facets of the natural gas industry (NGI) from well development through transmission and storage of natural gas. The multitude of chemicals used, combined with the dozens of chemical manufacturers and/or suppliers has lead to the availability of hundreds of possible chemical products. Because of the widespread use of chemical products and their numerous sources, the NGI needs access to consistent data regarding their effectiveness and potential environmental impacts. The objective of this work was to evaluate the effectiveness and potential environmental impacts of, chemical products used in the NGI. This assessment was initially focused on biocides and corrosion inhibitors and their use in the gas production, storage and transmission facilities, The overall approach was obtain the necessary data on chemical use and effectiveness directly from the oil and gas industry, supplemented with data/information obtained from the published ...

1995-03-27

195

Waste treatment by dialysis. (Latest citations from Pollution abstracts). Published Search  

Energy Technology Data Exchange (ETDEWEB)

The bibliography contains citations concerning the use of dialysis in the treatment of wastewaters. Techniques for the removal of metals, ammonia, waste acids, nitrates, and phosphates are described. Special attention is given to the desalination of liquid wastes. Applications of this technology to the treatment of effluent from the agrochemical, petrochemical, tanning, and electroplating industries are discussed. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

1996-02-01

196

Simultaneous ultraviolet spectrophotometric determination of nitrate and nitrite in water  

Energy Technology Data Exchange (ETDEWEB)

A rapid and accurate method for the direct simultaneous determination of nitrate and nitrite is proposed. The method is applied to the determination of nitrate and nitrite in rainwater and wastewater without preliminary separation. The determinations are performed by a CPA matrix method with ultraviolet spectrophotometric detection. The results obtained are in agreement with those obtained by conventional methods for the determination of nitrate and nitrite.

1991-02-01

197

Siemens provides treatment packages for oil production  

British Library Electronic Table of Contents (United Kingdom)

Modec International Inc has selected Siemens Water Technologies to provide sea-water reverse osmosis (SWRO) systems for several floating, production, storage and offloading (FPSO) vessels that are to be operated in deep-water locations. Siemens is also supplying a wastewater reuse system to one of Brazils largest refineries.

2010-01-01

198

Nitrite removal from marine aquaculture wastewater using electrochemical process  

International Nuclear Information System (INIS)

The hazardous and toxic nature of some of the constituent such as nitrite in the aquaculture wastewater is of major concern. Present study focuses the removal of nitrite from the aquaculture wastewater prior to disposal. Effect of certain operational parameters such as electrode material, current density, initial pH, and electrode spacing on nitrite removal from aquaculture wastewater was elucidated. Better nitrite removal efficiency achieved when nickel used as compared to stainless steel, graphite and aluminum electrodes. Nitrite removal is positively related to the current density however, increase is up to 31.4% when current density increased from 2.5 to 9.3 mA/cm/sup 2/. Further increase in current density does not improve the process efficiency. Removal efficiency of electrochemical process decreased with the increase in initial pH of test solution. However, with the passage of time this difference is diminishing. ...

3183-01-01

199

Inland wetlands legislation and management. (Latest citations from the NTIS data base). Published Search  

Energy Technology Data Exchange (ETDEWEB)

The bibliography contains citations concerning Federal and state laws and management programs for the protection and use of inland wetlands. Utilization of wetlands to control highway runoff and community wastewater is discussed. Wetlands protection programs, restoration projects, resource planning, and wetlands identification methods are cited. References to coastal and salt water wetlands are not included in this bibliography. (Contains 250 citations and includes a subject term index and title list.)

1992-05-01

200

Engineering approaches to ecosystem restoration  

Energy Technology Data Exchange (ETDEWEB)

This proceedings CD ROM contains 127 papers on developing and evaluating engineering approaches to wetlands and river restoration. The latest engineering developments are discussed, providing valuable insights to successful approaches for river restoration, wetlands restoration, watershed management, and constructed wetlands for stormwater and wastewater treatment. Potential solutions to a wide variety of ecosystem concerns in urban, suburban, and coastal environments are presented.

1998-07-01

201

Chapter 11 Aqueous Solutions  

Wastenet

...Chapter 11 Aqueous Solutions Chapter 11 Aqueous Solutions Download the entire chapter (PDF-136k) Drilling to China More water than rivers Saving the aquifer Drying with Xeriscapes Everywhere in the house Rainwater and graywater Creating urban watersheds Wastewater equals ...3851 Powered by Intrcomm Technology's SMC ...

202

Aerosols Equipment in Brazil on Environmental Expert  

Wastenet

... Hale, Markku Kulmala, 373.43 EUR; 225.00 USD; 276.00 GBP... More Journals » MAGAZINES & JOURNALS Environmental Quarterly - 2009 Fall Trinity`s Environmental Quarterly (EQ) magazine co... Industrial Wastewater Responsible for managing your company`s wastes?... ...

204

PPT Slide  

Indian Academy of Sciences (India)

central server with search facility involving all partner journals ...

211

Performance Assessment Monitoring Plan for the Hanford Site Low-Level Burial Grounds  

Energy Technology Data Exchange (ETDEWEB)

The U.S. Department of Energy Order 435.1, Radioactive Waste Management, requires a disposal authorization statement authorizing operation (or continued operation) for low-level waste disposal facilities. In fulfillment of these requirements, a disposal authorization statement was issued on October 25, 1999, authorizing the Hanford Site to transfer, receive, possess, and dispose of low-level radioactive waste at the 200 East Area burial grounds and the 200 West Area burial grounds. One of the conditions is that monitoring plans for the 200 East Area and 200 West Area low-level burial grounds be written and approved by the Richland Operations Office. As a result of a record of decision for the Hanford Site Solid Waste Program and acceptance of the Hanford Site Solid Waste Environmental Impact Statement, the use of the low-level burial ground (LLBG) as a disposal facility for low-level and mixed low-level wastes has been restricted to lined ...

2006-03-30

212

Vacuum ultraviolet radiometry of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two quantities are combined to ...

1995-10-01

213

VUV efficiency and radiant emittance characterization of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

The pure xenon dc positive column discharge has been characterized for various xenon pressures, currents, and discharge tube radii. The absolute output at the 147 nm resonance transition has been measured using two independent techniques to yield the radiant emittance at 147 nm (power per unit surface area). The efficiency of 147 nm production is obtained by combining the measured radiant emittance with the measured electrical power per unit length deposited in the gas. The radiant emittance and the efficiency are the two principle figures of merit for characterizing the discharge as a source of VUV radiation. It is observed that the trends in efficiency and radiant emittance change substantially when the discharge transitions from two-step electron impact excitation/ionization at higher pressures to single-step electron impact ionization at lower pressures. Modeling of the xenon positive column ...

1996-12-31

214

Recurrent plot analysis of discharge sequences in tracking test of polybutylene polymers  

Energy Technology Data Exchange (ETDEWEB)

Polymers are required to use in radiation environments as insulation materials. However, they often suffer from tracking failure. There is an increasing demand to evaluate radiation effects on dielectric performance. This paper presents a recurrence plot (RP) approach to analyse surface discharge sequences of gamma-ray irradiated polymer materials based on tracking test. Studying the non-linear characteristics of discharge sequences can assist in understanding the underlying mechanism of the discharge process. Discharge sequences of the test are extended to m-dimensional phase space by using the phase space reconstructed method. As test samples, polybutylene terephthalate (PBT) and polybutylene naphthalate (PBN) were irradiated to 100 kGy and then up to 1 MGy with a dosage rate of 10 kGy h{sup -1} by using a {sup 60}Co gamma source. The tracking tests were carried out according to the test method ...

2008-10-07

215

Mercury-free fluorescent lighting  

Energy Technology Data Exchange (ETDEWEB)

A brief comparative review of possible mercury free fluorescent lighting technologies is presented, including rare-gas positive column discharges, molecular discharges, and dielectric barrier discharges. Detailed experimental results on xenon positive column discharges will then be considered. In order to judge whether xenon-based discharges are a viable UV source it is necessary to measure the radiant emittance (power per unit area) for the vacuum ultraviolet (VUV) resonance xenon emission at 147 nm. Two techniques to determine the VUV radiant emittance have been developed and applied to xenon discharges. One method combines the measured resonance level density using absorption spectroscopy and a calculation of the trapped decay rate for the resonance radiation to arrive at the radiant emittance at 147 nm. A second method utilizes a direct measurement of the ...

1996-05-01

216

Generation of ozone by pulsed corona discharge over water surface in hybrid gas-liquid electrical discharge reactor  

International Nuclear Information System (INIS)

Ozone formation by a pulse positive corona discharge generated in the gas phase between a planar high voltage electrode made from reticulated vitreous carbon and a water surface with an immersed ground stainless steel plate electrode was investigated under various operating conditions. The effects of gas flow rate (0.5-3 litre min"-"1), discharge gap spacing (2.5-10 mm), applied input power (2-45 W) and gas composition (oxygen containing argon or nitrogen) on ozone production were determined. Ozone concentration increased with increasing power input and with increasing discharge gap. The production of ozone was significantly affected by the presence of water vapour formed through vaporization of water at the gas-liquid interface by the action of the gas phase discharge. The highest energy efficiency for ozone production was obtained using high voltage pulses of approximately 150 ns duration in Ar/O_2 ...

2005-02-07

217

Zn/gelled 6M KOH/O{sub 2} zinc-air battery  

Energy Technology Data Exchange (ETDEWEB)

The gel electrolyte for the zinc-air cell was prepared by mixing hydroponics gel with a 6M potassium hydroxide aqueous solution. The self-discharge of cells was characterized by measuring the open-circuit voltage. The effect of a discharge rate of 50mA constant current on cell voltage and plateau hour, as well as the voltage-current and current density-power density were measured and analysed. The electrode degradation after discharge cycling was characterized by structural and surface methods. The oxidation of the electrode surface further blocked the utilization of the Zn anode and was identified as a cause for the failure of the cell. (author)

2006-09-13

218

Oxidation of Propylene with Oxygen and Air in a Barrier Discharge in the Presence of Octane  

British Library Electronic Table of Contents (United Kingdom)

Oxidation of propylene with oxygen, air and a mixture of nitrogen?oxygen in a barrier discharge is investigated. The selectivity towards formation of propylene oxide in pure oxygen is shown to be as high as 45 wt% and the propylene conversion ratio is found to be 12.9 wt%. In the oxidation with air, the propylene oxide selectivity is 23 wt%, while the conversion is 7.5 wt%. The values of propylene conversion and selectivity towards formation of propylene oxide in a barrier discharge are consistent with those obtained by the thermocatalytic methods for production of propylene oxide.

2011-01-01

219

Ignition system  

Energy Technology Data Exchange (ETDEWEB)

This patent describes an ignition system of an internal combustion engine which consists of: a permanent magnet supported by a rotary member of the engine adapted to rotate in synchronism with a rotary shaft of the engine; a generating coil for generating an electromotive force to produce an electric current as the permanent magnet acts on the generating coil during the rotation of the rotary member; an ignition capacitor charged by the electric current generated by the generating coil; a thyristor caused to turn on by a counter electromotive force generated by the generating coil to thereby cause the ignition capacitor to begin to discharge; and an ignition coil generating a high voltage as the ignition capacitor begins to discharge, to cause a spark discharge to take place in an ignition plug of the internal combustion engine.

1986-09-16

220

Glow Discharge Plasma Nitriding of AISI 304 Stainless Steel  

International Nuclear Information System (INIS)

Glow discharge plasma nitriding of AISI 304 austenitic stainless steel has been carried out for different processing time under optimum discharge conditions established by spectroscopic analysis. The treated samples were analysed by X-ray diffraction (XRD) to explore the changes induced in the crystallographic structure. The XRD pattern confirmed the formation of an expanded austenite phase (#gamma#_N) owing to incorporation of nitrogen as an interstitial solid solution in the iron lattice. A Vickers microhardness tester was used to evaluate the surface hardness as a function of indentation depth (#mu#m). The results showed clear evidence of surface changes with substantial increase in surface hardness.

2007-08-01

221

Dependence of thermal plasma jet temperature on discharge power and gas flow rate  

International Nuclear Information System (INIS)

With the help of heat balance equation and high temperature thermodynamic function, the calibration relation of jet temperature with discharge power, gas flow rate was obtained for nitrogen thermal plasma. It was shown that the results were agreed with the principle of similarity. The jet temperature was a function of Peff/f, instead of a general two variables function of Peff and f, which were effective discharge power and working gas flow rate, respectively. A related discussion has been given; it will be referable to thermal plasma applications. (authors)

2008-03-01

223
224

Syndromic management of urethral discharge in Ghanaian pharmacies  

UK PubMed Central (United Kingdom)

Objectives: To evaluate the training of pharmacists in Accra, Ghana, in the syndromic management of STIs. Methods: We randomly selected 50 pharmacy outlets that had...Full Text Available

2000-12-01

225

SAFETY--Water Resources Division National Pollutant Discharge...  

Science.gov (United States)

Provisions (a) NPDES field personnel shall be currently trained and certified in CPR and basic first-aid procedures. (b) NPDES field personnel shall be aware of the...

2011-09-24

226

REVIEW OF EXPLOSIVE (CHEMICAL) FORMING  

Science.gov (United States)

... explosive (shotgun shells, etc.) method of forming is being replaced--for the most part--by the electri- cal discharge and magnetic forming methods. ...

1965-04-01

227

Plasma oxidation for achieving supported TiO2 photocatalysts derived from adsorbed TiCl4 using dielectric barrier discharge  

International Nuclear Information System (INIS)

At atmospheric pressure and room temperature, dielectric barrier discharge induced plasma oxidation for achieving supported TiO2 photocatalysts derived from TiCl4 adsorbed onto ?-Al2O3 pellets was studied. The supported TiO2/?-Al2O3photocatalysts prepared by a cyclic 'adsorption-discharge' approach, without requirement of heat treatment, exhibit high activity in the photocatalytic degradation reaction of formaldehyde. The mass spectra and optical emission spectra during O2/Ar discharge for oxidizing the adsorbed-state TiCl4 were measured. The mechanism for the TiO2 formation from adsorbed-state TiCl4 by plasma oxidation was discussed.

2007-03-21

228

Ozone production process in pulsed positive dielectric barrier discharge  

International Nuclear Information System (INIS)

The ozone production process in a pulsed positive dielectric barrier discharge (DBD) is studied by measuring the spatial distribution of ozone density using a two-dimensional laser absorption method. DBD occurs in a 6 mm point-to-plane gap with a 1 mm-thick glass plate placed on the plane electrode. First, the propagation of DBD is observed using a short-gated ICCD camera. It is shown that DBD develops in three phases: primary streamer, secondary streamer and surface discharge phases. Next, the spatial distribution of ozone density is measured. It is shown that ozone is mostly produced in the secondary streamer and surface discharge, while only a small amount of ozone is produced in the primary streamer. The rate coefficient of the ozone production reaction, O + O_2 + M #-># O_3 + M, is estimated to be 2.5 x 10"-"3"4 cm"6 s"-"1.

2007-01-07

229

National Advisory Committee for Aeronautics 1952 - NASA Technical ...  

Science.gov (United States)

By Charles E. Watkins. 2458. An Instrument Employing a Coronal Discharge for ..... Grover, W. S. Hyler, and L. R. Jackson. 2640. Interaction of Column and ...

230

Military Handbook: Electrostatic Discharge Control Handbook ...  

Science.gov (United States)

... (Metric) 80 Page 24. MIL-HDBK-263B MIL-STD-2073-1 - DOD Materiel Procedures for Development and Application of Packaging Requirements. ...

1994-07-31

231

Microwave excitation of a CO/sub 2/ laser. Master's thesis  

Energy Technology Data Exchange (ETDEWEB)

A flowing carbon dioxide laser was operated at low pressures up to 4 torr. Excitation of the laser was provided using various combinations of direct current (DC), pulsed microwave, and continuous wave (CW) microwave excitation. The microwaves were in the 2.45 GHz band and were coupled into the gas using a slow-wave interdigital transmission line. Laser output of 25 milliwatts (mw) was achieved using a DC discharge only. A combination of a DC discharge and pulsed microwaves doubled the output and resulted in some modulation. Changing the laser gas mixture and pulsed microwave field characteristics allowed some flexibility in the modulation. Lasing was not achieved with excitation from the CW microwaves alone due to the formation of localized discharges. Using pulsed microwaves to sustain the discharge and CW microwaves to pump the laser, a quasi-CW output of 55 mw was achieved.

1983-12-01

232

Electron density and collision frequency of microwave resonant cavity produced discharges. [Progress report  

Energy Technology Data Exchange (ETDEWEB)

This progress report consists of an article, the abstract of which follows, and apparently the references and vita from a proposal. A review of perturbation diagnostics applied to microwave resonant cavity discharges is presented. The classical microwave perturbation technique examines the shift in the resonant frequency and cavity quality factor of the resonant cavity caused by low electron density discharges. However, modifications presented here allow the analysis to be applied to discharges with electron densities beyond the limit predicted by perturbation theory. An {open_quote}exact{close_quote} perturbation analysis is presented which models the discharge as a separate dielectric, thereby removing the restrictions on electron density imposed by the classical technique. The {open_quote}exact{close_quote} method also uses measurements of the shifts in the resonant conditions of the cavity. Thirdly, ...

1992-12-31

233

Effect of the tide on the diffusion of "3H in the liquid effluent discharged from Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

The tide field at the time of liquid effluent discharging from Daya Bay nuclear power station, and the average water speed at the monitoring points in west Daya Bay from the time of discharging to the time of sampling were calculated by ADI (Alternating Direction Implicit) method. By comparing analysis, the difference of "3H diffusion between spring tide and neap tide (the expansion of "3H within one day of spring tide is greater than that within one day of neap tide) was found. So, an equivalent diffusion time is introduced to modify the original model, and a better attenuation relation between the average "3He concentration in west Daya Bay and the time since the liquid "3H discharging is obtained. (authors)

2006-07-01

234

Do Dreissenid Mussels Affect Lake Erie Ecosystem Stability Processes?  

Science.gov (United States)

... associated with non-reporting of phosphorus input from combined sewer overflow discharge all could potentially play a part in ... ...

235

Development of Plasma Technologies at IPP NSC KIPT  

International Nuclear Information System (INIS)

Plasma Technologies in Institute of Plasma Physics of the NSC KIPT are recently developed in the following directions. Material surfaces modification under their irradiation with pulsed plasma streams of different working gases. Besides traditional analysis of improvements of tribological characteristics and structural-phase changes of the modified layers recently we started investigations of material corrosions characteristic improvement under influence of pulsed plasma on the material surfaces. As to the surface coatings in arc discharges of Bulat type devices, new trends are related with multi-layers coatings, using Ti-AI-N coatings in cutting tools, using high frequency discharges or combined HF- and arc discharges for increasing the nomenclature of goods to be coated. Development of ozonators is respectively new area for IPP NSC KIPT. On the base of barrier high-frequency discharge there were ...

2001-09-19

236

Interim safety basis for fuel supply shutdown facility  

Energy Technology Data Exchange (ETDEWEB)

This ISB in conjunction with the new TSRs, will provide the required basis for interim operation or restrictions on interim operations and administrative controls for the Facility until a SAR is prepared in accordance with the new requirements. It is concluded that the risk associated with the current operational mode of the Facility, uranium closure, clean up, and transition activities required for permanent closure, are within Risk Acceptance Guidelines. The Facility is classified as a Moderate Hazard Facility because of the potential for an unmitigated fire associated with the uranium storage buildings.

1995-05-23

237

Decommissioning of facility for use of radioisotopes on waste management and disposal facility  

Energy Technology Data Exchange (ETDEWEB)

All the tests have been finished up in the Waste Management and Disposal Facility which has been used for the safety tests of solidified radioactive waste on sea dumping disposal. The decommissioning of this facility was performed for use of radioisotopes. This report describes the plan on decommissioning of facility for use of radioisotopes, the contamination checking methods and measurement of radioactivity, the fore case and practice for amount of generated radioactive wastes, the operation procedures for dismantlement, the safety measures, the expenses for decommissioning and so on. (author)

1999-09-01

238

Potential for energy production and use from biogas in Brazil; Potencial de aproveitamento energetico do biogas no Brasil  

Energy Technology Data Exchange (ETDEWEB)

Biogas, produced from anaerobic digestion of organic matter in domestic, industrial and rural wastewaters and residuals, represent an alternative and renewable source of energy, with growing use worldwide. In Brazil, high population and its spatial concentration and expressive agricultural and agricultural-industrial production indicate a substantial potential of biogas production. The results presented in this work show a potential of biogas production of almost 2 billion cubic feet a day of CH{sub 4}. Viability of biogas production and use depends substantially on project scale. Generally, biogas projects are viable from landfills and domestic wastewater treatment for populations higher than 50,000 inhabitants and swine and dairy farms with at least 5,000 and 1,000 animals, respectively. Biogas is also competitive when compared to fossil fuels used in industry and transport. Despite incentive mechanisms for biogas production and use, like ...

2009-12-15

239

Ceriodaphnia and Chironomus in situ toxicity tests assessing the wastewater treatment efficacy of constructed wetlands  

Energy Technology Data Exchange (ETDEWEB)

In situ toxicity tests were designed for Ceriodaphnia dubia and Chironomus tentans as part of a larger study designed to assess the effectiveness of constructed wetlands for the treatment of wastewater produced by oil production at Suncor OSG. The artificial wetlands were 50m long by 3m wide, with three replicates of the control and the treatment. Each wetland had four sample sites equidistant along its length, creating a gradient of treatment from site A being the most toxic to site D being the least toxic. Each test was conducted twice during the summer of 1994. Both the Ceriodaphnia and Chironomus test cages were a flow through design to allow for maximal exposure to the water within the wetlands. Mortality and reproduction were used as endpoints for Ceriodaphnia, whereas mortality and growth were used as endpoints for the Chironomus test. Test durations were fifteen and ten days respectively. Chironomus had very high mortality along the entire wetlands whereas ...

1995-12-31

240

Biosorption of heavy metals from wastewater by biosolids  

Energy Technology Data Exchange (ETDEWEB)

In a study where the removal of heavy metals from wastewater is the primary aim, the biosorption of heavy metals onto biosolids prepared as Pseudomonas aeruginosa immobilized onto granular activated carbon was investigated in batch and column systems. In the batch system, adsorption equilibriums of heavy metals were reached between 20 and 50 min, and the optimal dosage of biosolids was 0.3 g/L. The biosorption efficiencies were 84, 80, 79, 59 and 42 % for Cr(VI), Ni(II), Cu(II), Zn(II) and Cd(II) ions, respectively. The rate constants of biosorption and pore diffusion of heavy metals were 0.013-0.089 min{sup -1} and 0.026-0.690 min{sup -0.5}. In the column systems, the biosorption efficiencies for all heavy metals increased up to 81-100 %. The affinity of biosorption for various metal ions towards biosolids was decreased in the order: Cr = Ni > Cu > Zn > Cd. (Abstract Copyright [2006], Wiley Periodicals, Inc.)

2006-08-15

241

Advanced Flue Gas Desulfurization (AFGD) Demonstration Project, A DOE Assessment  

Science.gov (United States)

The AFGD process as demonstrated by Pure Air at the Bailly Station offers a reliable and cost-effective means of achieving a high degree of SO{sub 2} emissions reduction when burning high-sulfur coals. Many innovative features have been successfully incorporated in this process, and it is ready for widespread commercial use. The system uses a single-loop cocurrent scrubbing process with in-situ oxidation to produce wallboard-grade gypsum instead of wet sludge. A novel wastewater evaporation system minimizes effluents. The advanced scrubbing process uses a common absorber to serve multiple boilers, thereby saving on capital through economies of scale. Major results of the project are: (1) SO{sub 2} removal of over 94 percent was achieved over the three-year demonstration period, with a system availability exceeding 99.5 percent; (2) a large, single absorber handled the combined flue gas of boilers generating 528 MWe of power, and no spares were required; (3) direct ...

2001-08-31

242

QUEOS, a simulation-experiment of the premixing phase of a steam explosion with hot spheres in water base case experiments  

Energy Technology Data Exchange (ETDEWEB)

This report describes the QUEOS facility and gives the results of the first test series performed up to 6/1995. The premixing phase of a steam explosion is investigated experimentally with simulant materials. The transient three-dimensional multi-component interaction of molten corium with water is studied using a large number of small solid spheres at temperatures up to 2300 C. The objective of the experiments is to establish a data base for testing the models of heat and momentum transfer in multi-fluid codes as well as the code`s capability to correctly describe multiphase flows. The experiments have the advantage that the diameter of the `coarse melt fragments` are known and that detailed measurements can be performed without the danger of a steam explosion. In this first series of experiments up to 10 kg of spheres (max. 24000 pieces) were used. The spheres, made of molybdenum or zirconia, were heated to temperatures up to 2000 C and are ...

1996-04-01

243

Wetland treatment of oil and gas well wastewaters. Quarterly technical report, May 25, 1992---August 24, 1992  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to extend the knowledge base for wetland treatment to include processes and substances of particular importance to small, on-site systems receiving oil and gas well waste water. Collection of data on the sorption of heavy metals and the degradation of toxic organics is one of the key tasks. The toxic organics phenolics and anthracene, and chromium and copper have been selected as target adsorbates. An information search was performed on oil refinery waste treatment wetland systems.

1995-11-01

244

Removal of uranium by biosorption  

Energy Technology Data Exchange (ETDEWEB)

The technology developed here will exploit the ability of microorganisms to remove dissolved metals from aqueous solutions. Microbial sorbents for uranium will be immobilized biosorbents will be deployed ex situ within flow-through reactors for the continuous or semicontinuous treatment of recovered wastewaters. The proposed technology will primarily be applied within a pump-and-treat process using immobilized biosorbents for the large-scale, long-term remediation of uranium-laden surface water or groundwater impoundments (environmental restoration). The technology may be equally useful as an ``end-of-pipe`` treatment of process effluents (waste management). Successful operation of this process will achieve immobilization of the targeted waste and accompanying volume reduction.

1993-06-01

245

FCE power plants for renewable biogas project in San Diego  

British Library Electronic Table of Contents (United Kingdom)

FuelCell Energy in Connecticut has sold 4.5 MW worth of power plants to California renewable energy company BioFuels Fuel Cells, part of New Energy Capital and BioFuels Energy. Three molten carbonate fuel cell power plants - a 2.8 MW DFC3000 unit, a 1.4 MW DFC1500 system, and a 300 kW DFC300 unit - will be installed at three locations in the San Diego area, and utilize purified biogas from the Point Loma wastewater treatment plant as their primary fuel source.

2010-01-01

246

Case studies of hazardous-waste treatment to remove volatile organics. Volume 2  

Energy Technology Data Exchange (ETDEWEB)

Case studies are presented for treatment of refinery wastes in a pilot-scale thin-film evaporator, the removal of volatiles from industrial wastewater for two steam strippers, and the removal of semivolatiles from water by steam stripping followed by liquid-phase carbon adsorption. The report provides data on removal efficiency, air emissions, process residuals, treatment costs, and process limitations. Details on sampling and analytical procedures, quality assurance, and process data are contained in the Appendixes (Volume II).

1987-11-01

247

Case studies of hazardous-waste treatment to remove volatile organics. Volume 1  

Energy Technology Data Exchange (ETDEWEB)

Case studies are presented for treatment of refinery wastes in a pilot-scale thin-film evaporator, the removal of volatiles from industrial wastewater for two steam strippers, and the removal of semivolatiles from water by steam stripping followed by liquid-phase carbon adsorption. The report provides data on removal efficiency, air emissions, process residuals, treatment costs, and process limitations. Details on sampling and analytical procedures, quality assurance, and process data are contained in the Appendixes (Volume II).

1987-11-01

248

Trivalent chromium removal from wastewater using low cost activated carbon derived from agricultural waste material and activated carbon fabric cloth  

International Nuclear Information System (INIS)

An efficient adsorption process is developed for the decontamination of trivalent chromium from tannery effluents. A low cost activated carbon (ATFAC) was prepared from coconut shell fibers (an agricultural waste), characterized and utilized for Cr(III) removal from water/wastewater. A commercially available activated carbon fabric cloth (ACF) was also studied for comparative evaluation. All the equilibrium and kinetic studies were conducted at different temperatures, particle size, pHs, and adsorbent doses in batch mode. The Langmuir and Freundlich isotherm models were applied. The Langmuir model best fit the equilibrium isotherm data. The maximum adsorption capacities of ATFAC and ACF at 25 deg. C are 12.2 and 39.56 mg/g, respectively. Cr(III) adsorption increased with an increase in temperature (10 deg. C: ATFAC-10.97 mg/g, ACF-36.05 mg/g; 40 deg. C: ATFAC-16.10 mg/g, ACF-40.29 mg/g). The kinetic studies were conducted to delineate the effect of temperature, ...

2006-07-31

249

Enhanced biosorption of nickel(II) ions by silica-gel-immobilized waste biomass: Biosorption characteristics in batch and dynamic flow mode  

Energy Technology Data Exchange (ETDEWEB)

Batch and dynamic flow biosorption studies were carried out using the waste biomass entrapped in silica-gel matrix for the removal of nickel(II) ions from synthetic solutions and real wastewater. Batch biosorption conditions were examined with respect to initial pH, S/L ratio, contact time, and initial nickel ion concentration. Zeta potential measurements showed that immobilized biosorbent was negatively charged in the pH range of 3.0-8.0. The immobilized biomass was found to possess relatively high biosorption capacity (98.01 mg g{sup -1}), and biosorption equilibrium was established in a short time of operation (5 min). The equilibrium data were followed by Langmuir, Freundlich, and Dubinin-Radushkevich isotherm models. Scanning electron microscope analysis was used to screen the changes on the surface structure of the waste biomass after immobilization and nickel(II) biosorption. Sorbent-sorbate interactions were confirmed by Fourier transform infrared ...

2009-04-30

250

Effect of sulfate on anaerobic degradation of benzoate in UASB reactors  

Science.gov (United States)

Anaerobic processes have been widely used for the treatment of various high-strength industrial wastewaters. However, application has been limited for the treatment of sulfate-rich industrial wastewaters, such as those from the petrochemical, and mining industries. Wastewaters containing benzoate and sulfate were treated in two upflow anaerobic sludge blanket (UASB) reactors at 34--37 C for 320 d. The sulfate concentration was increased stepwise in Reactor-A up to 7,500 mg/L, and was kept mostly constant at 3,000 mg/L in Reactor-B. Both reactors removed over 98% of organic chemical-oxygen demand (COD) for sulfate up to 6,000 mg/L, despite the fact that the mixed liquor contained up to 769 mg S/L of total sulfides and up to 234 mg S/L of dissolved H{sub 2}S. Sulfate0reducing efficiency decreased with the increase in sulfate concentration, but increased with time at each sulfate concentration. Reactor-B consistently reduced ...

1997-04-01

251

Effect of hydraulic retention time on the biodegradation of complex phenolic mixture from simulated coal wastewater in hybrid UASB reactors  

International Nuclear Information System (INIS)

This study describes the feasibility of anaerobic treatment of complex phenolics mixture from a simulated synthetic coal wastewater using four identical 13.5 L (effective volume) bench scale hybrid up-flow anaerobic sludge blanket (HUASB) (combining UASB + anaerobic filter) reactors at four different hydraulic retention times (HRT) under mesophilic (27 #+-# 5 "oC) conditions. Synthetic coal wastewater with an average chemical oxygen demand (COD) of 2240 mg/L and phenolics concentration of 752 mg/L was used as substrate. The phenolics contained phenol (490 mg/L); m-, o-, p-cresols (123.0, 58.6, 42 mg/L); 2,4-, 2,5-, 3,4- and 3,5-dimethyl phenols (6.3, 6.3, 4.4 and 21.3 mg/L) as major phenolic compounds. The study demonstrated that at optimum HRT, 24 h, and phenolic loading rate of 0.75 g COD/(m"3-d), the phenolics and COD removal efficiency of the reactors were 96% and 86%, respectively. Bio-kinetic models were applied to data obtained from ...

2008-05-01

252

Thermal transport during electron cyclotron heating in the TEXT tokamak  

International Nuclear Information System (INIS)

Electron Cyclotron Heating experiments have been performed on the TEXT tokamak using Varian gyrotron. Some degradation of electron energy confinement is observed for sawtoothing and non-sawtoothing discharges. Sharp electron temperature profiles are produced in high-q discharges by extremely localized ECH power deposition.

1989-05-01

253

The possible impact of atmospheric radioactive discharges from UK nuclear installations on acid deposition  

International Nuclear Information System (INIS)

The effect of atmospheric radioactive emissions from United Kingdom nuclear installations on acid deposition is assessed. Nitrogen oxide and ozone production resulting from and associated with discharges of airborne radioactivity, comparison with conventional emissions, and the direct effects of radioactive emissions on trees, are all discussed. (UK).

254

The low-current low-temperature plasma generators  

Energy Technology Data Exchange (ETDEWEB)

In this article, the results of low-current gas-discharge plasma generator investigations carried out by a group of scientists from the Kazan' Aviation Institute are presented. When considered necessary, the results are compared with the data obtained by other authors. The basic configurations and theoretical calculation peculiarities of plasma generators are described. The electrical, thermal and energy characteristics of discharges in gas flows, as well as summarised empirical formulae and experimental data necessary for calculations and design of plasma devices are presented. (author)

2000-07-01

255

Superconducting magnetic system with the controllable inductance of a winding  

International Nuclear Information System (INIS)

The experimental superconducting magnetic system of 0.5 MJ energy storage is described. The step variation of the winding inductance provides a control by the discharge current at the energy output on a high-ohmic load. The voltage on a load is 45 kV at the current 1100 A under the controllable discharge conditions. The energy transfer coefficient constitutes 0,76 under the maximum-to-minimal current ratio equal to 1.3. 7 refs., 3 figs., 2 tabs.

256

Modeling Transient Discharge into a Tunnel Drilled in a Heterogeneous Formation  

British Library Electronic Table of Contents (United Kingdom)

Abstract An analytical model is developed to predict transient discharge flow into a tunnel drilled at various speeds through a heterogeneous formation. This model relies on simplifying assumptions commonly enforced in hydrogeologic engineering, and combines the convolution and superposition principles to account for composite sections with arbitrary parametric contrasts. An application to the data monitored during the exploratory drilling of an Alpine tunnel confirms the validity of the approach.

2007-01-01

257

Breakdown and discharges in dense gases governed by runaway electrons  

Energy Technology Data Exchange (ETDEWEB)

The phenomenon of runaway electrons (REs) at high values of the ratio field intensity/gas number density {ital E}/{ital N} and {ital N} up to the Loshmidt number {ital N}{sub {ital L}}{approx_equal}2.7{times}10{sup 19} cm{sup {minus}3} is described. REs are shown to govern the breakdown and discharges at such condition. {copyright} {ital 1996 American Institute of Physics.}

1996-03-01

258

An Explanation for Positive Differential dc Voltage-Current Characteristics in Weakly Ionized, Low-Pressure Positive Column Gas Discharge Plasmas  

Energy Technology Data Exchange (ETDEWEB)

A physical explanation is given for the positive differential voltage-current characteristic seen at low current in weakly ionized, low-pressure positive column discharges in argon/mercury gas mixtures. {copyright} {ital 1996 The American Physical Society.}

1996-07-01

259

Minimizing energy consumption of accelerators and storage ring facilities  

Science.gov (United States)

The discussion of energy usage falls naturally into three parts. The first is a review of what the problem is, the second is a description of steps that can be taken to conserve energy at existing facilities, and the third is a review of the implications of energy consumption on future facilities.

260

Evaluation of the residual radiation field in the proton accelerator facility of the Proton Engineering Frontier Project (PEFP) in Korea  

British Library Electronic Table of Contents (United Kingdom)

In Korea, the Proton Engineering Frontier Project (PEFP) is building a proton linear accelerator facility with energy up to 100MeV and a beam current of 20mA. In this study, a radiation field after shutdown in the accelerator facility of the PEFP was evaluated for the purpose of the radiation shielding by using MCNPX code. A facility modeling was performed for the accelerator tunnel building, accelerator chain, target rooms and beam experiment hall. And radiation source terms were evaluated in the facility. With this facility, model and radiation source terms, the concentration of 41Ar was evaluated and the cooling time satisfying regulation in Korea was calculated.

2007-01-01

261

Trends and Controls on Summer Surface-Water Temperatures in Salmonid-Bearing Headwater Streams in Two Common Geomorphic Settings, Kenai Peninsula, Alaska  

Science.gov (United States)

Stream temperature is an important physical characteristic of headwater streams that plays a critical role in the presence and health of juvenile salmonids. Headwater stream temperature was documented in two geomorphic settings on the Kenai Peninsula, Alaska, focusing on the variation in temperature induced by diffuse groundwater discharge and variable air temperature. Eighteen headwater stream reaches were studied in four watersheds, with 11 drainageway sites and seven discharge-slope sites. In drainageway sites, low-gradient streams flow through broad valleys with groundwater-fed fen wetlands; in discharge-slope sites, high-gradient streams flow through narrow valleys with groundwater-fed slope wetlands. At all 18 sites, hourly stream temperatures were measured for one year. At one drainageway and one discharge-slope site, groundwater temperatures, stream stages, and groundwater heads in the local ...

2010-12-01

262

Non-thermal atmospheric pressure discharges for surface modification  

International Nuclear Information System (INIS)

Throughout the last decades, plasma technology has been established in a series of surface treatment applications, e.g. for semiconductor processing or optical coatings. The majority of plasma assisted technologies is based on low pressure processes. In recent years, however, non-thermal atmospheric pressure discharges have attracted considerable interest because of their simplified technical devices for industrial applications as compared to low pressure processes which require vacuum equipment. Hence, batch processing can be avoided, thus facilitating the implementation of plasma process steps into production lines. Investment costs are cut down significantly. The use of atmospheric pressure plasmas for technical applications dates back to the ozone production with dielectric barrier discharges (DBD) by Siemens in 1857. Lately, the application of atmospheric pressure plasmas for surface treatment has been reported, e.g. for the treatment of ...

263

Report on progress of researches by common utilization of JAERI nuclear facilities, for fiscal 1996  

Energy Technology Data Exchange (ETDEWEB)

This issue is the collection of the papers on progress of researches by common utilization of JAERI nuclear facilities. The 43 of the papers are indexed individually. (J.P.N.)

1998-01-01

264

Foodstuff Concentrations and Relocation Considerations Following a Tritium Oxide Release from SRS Tritium Facilities  

Energy Technology Data Exchange (ETDEWEB)

The ingestion pathway consequences following an accidental tritium release from the Savannah River Site Tritium Facilities are evaluated.

1999-05-18

265

Evaluation of the Cask Transportation Facility Modifications (CTFM) compliance to DOE order 6430.1A; FINAL  

International Nuclear Information System (INIS)

This report was prepared to evaluate the compliance of Cask Transportation Facility Modifications (CTFM) to DOE Order 6430.1A.

266

Cold vacuum drying facility design requirements; FINAL  

International Nuclear Information System (INIS)

This document provides the detailed design requirements for the Spent Nuclear Fuel Project Cold Vacuum Drying Facility. Process, safety, and quality assurance requirements and interfaces are specified.

267

Facility Effluent Monitoring Plan for Pacific Northwest National Laboratory Balance-of-Plant Facilities  

Energy Technology Data Exchange (ETDEWEB)

The Pacific Northwest National Laboratory (PNNL) operates a number of research and development (R and D) facilities for the Department of Energy on the Hanford Site. According to DOE Order 5400.1, a Facility Effluent Monitoring Plan is required for each site, facility, or process that uses, generates, releases, or manages significant pollutants or hazardous materials. Three of the R and D facilities: the 325, 331, and 3720 Buildings, are considered major emission points for radionuclide air sampling and thus individual Facility Effluent Monitoring Plans (FEMPs) have been developed for them. Because no definition of ''significant'' is provided in DOE Order 5400.1 or the accompanying regulatory guide DOE/EH-0173T, this FEMP was developed to describe monitoring requirements in the DOE-owned, PNNL-operated facilities that do not ...

1999-04-02

268

Thermal impact analysis of discharge of circulating cooling water at Daya Bay Nuclear Power Station (GNPS) and Ling'ao Nuclear Power Station (LNPS)  

International Nuclear Information System (INIS)

The circulating cooling water flowrate of GNPS and LNPS is totally about 190 m"3/s. Both stations are located on the western coast of semi-closed Daya Bay. A lot of studies concerning thermal impact of GNPS and LNPS have been carried out since 1987, including mathematical model, physical model, on-site survey and satellite remote sensing, etc. This paper describes the hydrological features of Daya Bay and discharge characteristics of circulating water of GNPS and LNPS, estimates the actual thermal impact of GNPS and LNPS, and indicates that it is advantageous for the dilution of circulating water while the two discharge channels of GNPS and LNPS are combined together towards east

2004-05-01

269

Theoretical study of the non-steady discharge at atmospheric pressure in pin-plate system and its application for ozone production  

International Nuclear Information System (INIS)

In this paper as a result of the theoretical studies and a numerical simulation we presented the following main conclusions: (i) for humid air at increasing pressure of 1.0133 10"5 Pa until 5.0665 10"5 Pa ozone concentrations during 2 centre dot 10"-"3 s become higher in 22 times. This fact we clear with structure of ozone-production reactions. In this case the harmful NO_x concentrations are 2-3 order lower than ozone one; (ii) it is shown that nitrogen is useful to ozone production in the discharge; (iii) based on ion collection we cleared increasing ignition discharge voltage at growing ozone concentrations even with low ozone concentrations.

270

The role of water and oxygen impurities on ozone production in a negative corona discharge of CO_2  

International Nuclear Information System (INIS)

The production of ozone in a negative corona discharge fed by carbon dioxide with embedded traces of oxygen and water has been studied. The presence of traces of oxygen in both pure and dry CO_2 leads to an increase in nascent ozone concentrations. In contrast, traces of water vapour (0-800 ppm) are shown to rapidly suppress ozone concentrations with the largest decreases being observed at lowest gas pressures in the discharge (300 Torr). The presence of water vapour did not considerably affect the electrical properties of negative dc corona suggesting that a chemical process is responsible for the ozone loss. We have shown that the addition of water up to a concentration of 1500 ppm has only a marginal effect on the processes of ozone formation but the catalytic cycle of ozone destruction involving OH radicals can be the reason for observed decrease in the total ozone concentration with increasing water concentration.

2007-11-07

271

The influence of contrasting suspended particulate matter transport regimes on the bias and precision of flux estimates  

British Library Electronic Table of Contents (United Kingdom)

A large database (507 station-years) of daily suspended particulate matter (SPM) concentration and discharge data from 36 stations on river basins ranging from 600?km2 to 600,000?km2 in size (USA and Europe) was collected to assess the effects of SPM transport regime on bias and imprecision of flux estimates when using infrequent surveys and the discharge-weighted mean concentration method. By extracting individual SPM concentrations and corresponding discharge values from the database, sampling frequencies from 12 to 200 per year were simulated using Monte Carlo techniques. The resulting estimates of yearly SPM fluxes were compared to reference fluxes derived from the complete database. For each station and given frequency, bias was measured by the median of relative errors between estima...

2006-01-01

272

Study of epileptiform activity in cerebral ganglion of mud crab Scylla serrata  

British Library Electronic Table of Contents (United Kingdom)

An attempt is made to induce in mud crab (Scylla serrata) epileptiform activities that resemble the generalized epileptic seizures. Cerebral ganglion of crab was exposed in situ, to a convulsant drug pentylenetetrazole (PTZ) 100?mM, for induction of seizures. Also, crabs were pretreated with antiepileptic drug viz sodium valproate (120??mol/l) to inhibit epileptiform activities. The surface electrical discharges of cerebral ganglion were recorded using Unkelscope (MIT, USA) in control as well as experimental animals. The cerebral ganglion of crab showed a pattern of high cerebral electrical discharges after PTZ treatment compared to control. The sodium valproate promoted sedative action in control and prevented PTZ-mediated epileptiform discharges. Glutamate and GABA contents in cerebral g...

2011-01-01

273

Removal of NO and SO2 in Corona Discharge Plasma Reactor with Water Film  

Science.gov (United States)

In this paper, a novel type of a corona discharge plasma reactor was designed, which consists of needle-plate-combined electrodes, in which a series of needle electrodes are placed in a glass container filled with flue gas, and a plate electrode is immersed in the water. Based on this model, the removal of NO and SO2 was tested experimentally. In addition, the effect of streamer polarity on the reduction of SO2 and NO was investigated in detail. The experimental results show that the corona wind formed between the high-voltage needle electrode and the water by corona discharge enhances the cleaning efficiency of the flue gas because of the presence of water, and the cleaning efficiency will increase with the increase of applied dc voltage within a definite range. The removal efficiency of SO2 up to 98%, and about 85% of NOx removal under suitable conditions is obtained in our experiments.

2004-04-01

274

Rapid detection of drugs in biofluids using atmospheric pressure chemi/chemical ionization mass spectrometry  

British Library Electronic Table of Contents (United Kingdom)

We have demonstrated that, with simple pH adjustment, volatile drugs such as methamphetamine, amphetamine, 3,4-methylenedioxymethamphetamine (MDMA), ketamine, and valproic acid could be analyzed rapidly from raw biofluid samples (e.g. urine and serum) without dilution, or extraction, using atmospheric pressure ionization. The ion source was a variant type of atmospheric pressure chemical ionization (APCI) that used a dielectric barrier discharge (DBD) to generate the metastable helium gas and reagent ions. The sample solution was loaded in a disposable glass pipette, and the volatile compounds were purged by nitrogen gas to be reacted with the metastable helium gas. The electrodes of the DBD were arranged in such a way that the generated glow discharge was confined within the discharge tub...

2009-01-01

275

Radio and television interference caused by corona discharges from high-voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmission line voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmission line conductors. Transmission line noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmission lines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, corona radio noise varies significantly with the weather and atmospheric conditions and generally increases by 10 to 30 dB in ...

1996-11-01

276

Radio and television interference caused by corona discharges from high-voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmission line voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmission line conductors. Transmission line noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmission lines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, corona radio noise varies significantly with the weather and atmospheric conditions and generally increases by 10 to 30 dB in ...

1995-10-01

277

Radio and television interference caused by corona discharges from high-voltage transmission lines  

International Nuclear Information System (INIS)

Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmission line voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmission line conductors. Transmission line noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmission lines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, corona radio noise varies significantly with the weather and atmospheric conditions and generally increases by 10 to 30 dB in ...

1996-04-09

278

RF conditioned dc discharges for excitation of rare gas halide lasers. Final report  

Energy Technology Data Exchange (ETDEWEB)

Results of experiments performed utilizing high-power microwave sources for laser-discharge switching and preionization are reported. These results are not definitive, but are promising. Significant preionization using microwaves is possible. Some ability to switch the discharge and operate a laser have been demonstrated. More work needs to be performed to perfect the microwave coupling to the laser mixture. In particular, experiments with the microwaves better concentrated between the electrodes should be performed. The best way to accomplish this appears to be using the side-feed geometry; however, a large expansion of the microwaves should occur (to well below the power able to break down the window), and then a cylindrical lens should be used to focus the microwaves between the electrodes. 2 references.

1983-01-01

279

Hydrogen-oxygen PEM regenerative fuel cell development at Nasa Glenn Research Center  

British Library Electronic Table of Contents (United Kingdom)

The closed-cycle hydrogen-oxygen PEM regenerative fuel cell (RFC) at Nasa Glenn Research Center has successfully demonstrated closed-cycle operation at rated power for multiple charge/discharge cycles. During the charge cycle the RFC has absorbed input electrical power simulating a solar day cycle ranging from zero to 15 kWe peak, and delivered steady 5 kWe output power for periods exceeding 8 h. Orderly transitions from charge to discharge mode, and return to charging after full discharge, have been accomplished without incident. The RFC is beginning to demonstrate its potential as an energy storage device for aerospace solar power systems such as solar electric aircraft, lunar and planetary surface installations - any airless environment where minimum system weight is critical. This hard...

2006-01-01

280

Development of ozone generator by modification of the field distribution  

International Nuclear Information System (INIS)

New methods have been established to enhance the ozone production of the surface discharge arrangement. One method sets the discharge electrode a short distance away from the surface of the dielectric material, whilst another uses a special power supply system resulting in a superimposed discharge. According to the experiments, significant differences have been found in the ozone production capacity of the different arrangements. The characteristics of the electric field distribution of the designs have been calculated using the finite element method for the potential; and the Donor-Cell method for the space charge calculation, and the results have been analysed. A method of analysis has been established for the calculated field characteristics, which provides two index numbers. The reasons are highlighted for the differences in ozone production in relation to the index numbers obtained from the fields' distributions of the ...

2008-12-01

281

Development of ambient sampling chemi/chemical ion source with dielectric barrier discharge  

British Library Electronic Table of Contents (United Kingdom)

The development of a new configuration of chemical ionization (CI)-based ion source is presented. The ambient air containing the gaseous sample is sniffed into an enclosed ionization chamber which is of sub-ambient pressure, and is subsequently mixed with metastable species in front of the ion inlet of the mass spectrometer. Metastable helium atoms (He*) are used in this study as the primary ionizing agents and are generated from a dielectric barrier discharge (DBD) source. The DBD is powered by an AC high-voltage supply and the configuration of the electrodes is in such a way that the generated plasma is confined within the discharge tube and is not extended into the ionization chamber. The construction of the ion source is simple, and volatile compounds released from the bulky sample can...

2010-01-01

282

Development document for proposed effluent limitations guidelines and standards for synthetic-based drilling fluids and other non-aqueous drilling fluids in the oil and gas extraction point source category  

Science.gov (United States)

The purpose of this rulemaking is to amend the effluent limitations guidelines and standards for the control of discharges of certain pollutants associated with the use of synthetic-based drilling fluids (SBFs) and other non-aqueous drilling fluids in portions of the Offshore Subcategory and Cook Inlet portion of the Coastal Subcategory of the Oil and Gas Extraction Point Source Category. These proposed limitations apply to discharges or effluent generated when oil and gas wells are drilled using SBFs or other non-aqueous drilling fluids (collectively referred to simply as SBFs) in coastal and offshore regions in locations where drilling wastes may be discharged.

1999-02-01

283

Degradation of antibiotics in water by non-thermal plasma treatment.  

Science.gov (United States)

The decomposition of three ?-lactam antibiotics (amoxicillin, oxacillin and ampicillin) in aqueous solution was investigated using a dielectric barrier discharge (DBD) in coaxial configuration. Solutions of concentration 100 mg/L were made to flow as a film over the surface of the inner electrode of the plasma reactor, so the discharge was generated at the gas-liquid interface. The electrical discharge was operated in pulsed regime, at room temperature and atmospheric pressure, in oxygen. Amoxicillin was degraded after 10 min plasma treatment, while the other two antibiotics required about 30 min for decomposition. The evolution of the degradation process was continuously followed using liquid chromatography-mass spectrometry (LC-MS), total organic carbon (TOC) and chemical oxygen demand (COD) analyses. PMID:21514950

2011-04-06

284

A nanosized silicon thin film as high capacity anode material for Li-ion rechargeable batteries  

Energy Technology Data Exchange (ETDEWEB)

Silicon thin film with thickness in range 1000-5300 A deposited on rough Cu foil by a radio frequency magnetron sputtering is used as anode materials for Li-ion rechargeable batteries. The SEM, XRD and TEM analysis reveals that the Si thin film has a floccular nano-sized multi-crystalline structure. Li ions insertion/extraction evaluation is performed mainly with constant current charge/discharge cycling and cyclic voltammetry (CV) at room temperature. The cycleability and reversible discharge capacity are found to depend on the film thickness, and thinner films give larger accommodation capacity. A 3120 A Si film provides a reversible specific capacity over 3500 mA hg{sup -1} with excellent cycleability under 0.5 C charge/discharge rate.

2006-07-15

286

The ALPHA programs and thermal-hydraulic facilities at PSI  

International Nuclear Information System (INIS)

... J. DREIER, M. HUGGENBERGER, C. AUBERT, TH BANDURSKI, F. DE

1999-12-01

288

Radiation facility with electron accelerator of the Institute for Nuclear Research of Ukraine, Kiev  

International Nuclear Information System (INIS)

Characteristics of the Ukrainian NSA NRI radiation facility for scientific researches and developments of industrial radiation technology are performed. Parts of the facility, design peculiarities of technical tools are described. Biological protection of the facility and radiation protection system, transport line, systems of technical provision and radiation measurements are discussed

2003-02-01

290

On technical opportunity of use of the pactel facility for investigation of coolant phenomenon in horizontal steam generators  

Energy Technology Data Exchange (ETDEWEB)

In this paper the possibility of using the test facility PACTEL concerning the investigations of thermal hydraulic special features of the primary coolant circuit acting under natural circulation is under consideration. It is suggested to study a stratification phenomenon of a coolant in upper plenum of a reactor and also a horizontal steam generator (HSG) hot collector temperature regime. For such investigations the facility must be modified. It is shown that this work is not large and expensive, as the facility is a lightly suitable unit for different researches. (orig.)

2001-07-01

291

On technical opportunity of use of the pactel facility for investigation of coolant phenomenon in horizontal steam generators  

International Nuclear Information System (INIS)

In this paper the possibility of using the test facility PACTEL concerning the investigations of thermal hydraulic special features of the primary coolant circuit acting under natural circulation is under consideration. It is suggested to study a stratification phenomenon of a coolant in upper plenum of a reactor and also a horizontal steam generator (HSG) hot collector temperature regime. For such investigations the facility must be modified. It is shown that this work is not large and expensive, as the facility is a lightly suitable unit for different researches. (orig.)

2001-03-20

292

Monte Carlo design calculations for a neutron imaging facility collimator  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for computed tomography and real-time neutron radiography is being developed at the University of Texas at Austin. The TRIGA reactor is a graphite-reflected Mark It pool-type research reactor. The neutron imaging facility will use beam port, which is at one end of a through part. Monte Carlo calculations were used to design the neutron collimator for this facility.

1996-12-31

294

Interim Safety Basis for Fuel Supply Shutdown Facility  

Energy Technology Data Exchange (ETDEWEB)

This ISB, in conjunction with the IOSR, provides the required basis for interim operation or restrictions on interim operations and administrative controls for the facility until a SAR is prepared in accordance with the new requirements or the facility is shut down. It is concluded that the risks associated with tha current and anticipated mode of the facility, uranium disposition, clean up, and transition activities required for permanent closure, are within risk guidelines.

2000-09-07

296

FFTF and the ASME Code  

Science.gov (United States)

Photographs are presented of the FFTF reactor facility, components, and some materials.

1978-01-01

298

Dioxins in the Baltic sea  

Wastenet

for municipal waste iron ore sinter plants incinerators for clinical waste facilities of the non-ferrous metal

299

Development of a Standard Data Base and Computer ...  

Science.gov (United States)

... (Author). Descriptors : (*TERMINAL FLIGHT FACILITIES ... PROGRAMMING, HANDLING), QUEUEING THEORY, STOCHASTIC PROCESSES ...

1973-01-01

302

BC  

Wastenet

all Certified ESM facilities capable of receiving used mobile phone waste from non-Annex VII countries.

304

53672  

Science.gov (United States)

... numbers of marine mammals during operation of an offshore liquefied natural gas (LNG) facility in the Massachusetts Bay for ... ...

305

21631  

Science.gov (United States)

... harassment, incidental to construction and operation of an offshore liquefied natural gas (LNG) facility in Massachusetts Bay. Under the ... ...

306

11328  

Science.gov (United States)

... harassment, incidental to construction and operation of an offshore liquefied natural gas (LNG) facility. Under the Marine Mammal Protection ... ...

307

Review of Regulatory Quality Assurance Requirements for the Operation of Nuclear R and D Facilities  

International Nuclear Information System (INIS)

Korea Atomic Energy Research Institute (KAERI) has many R and D facilities in operation, including HANARO research reactor, radioactive waste treatment facility (RWTF), post-irradiation examination facility (PIEF) and irradiated material test facility (IMEF). Recently, nation-wide interest is focused on the safety and security of major industrial facilities. Safe operation of nuclear facilities is imperative because of the consequence of public disaster by radiological release/ contamination, in case of an accident. Recently, Ministry of Science and Technology (MOST) of the Korean government announced amendments of Atomic Energy laws to enforce requirements of the physical protection and radiological emergency. In this paper, the context of amended Atomic Energy laws were reviewed to confirm quality assurance measures and identify additional QA activities, if ...

2005-10-27

308

Terminated Exploding Wire Energy Source.  

Science.gov (United States)

By placing a discharge or 'dump' tube across an exploding bridgewire load, it is possible to by-pass the electrical energy and terminate the explosion of the wire. The dump tube is triggered by a signal derived from the energy removed from the storage cap...

1965-01-01

309

Superior energy capacity of graphene nanosheets for a nonaqueous lithium-oxygen battery.  

Science.gov (United States)

Graphene nanosheets (GNSs) were synthesized and used as cathode active materials in a nonaqueous lithium-oxygen battery. The GNSs electrode delivered an extremely high discharge capacity in comparison to carbon powders, which is attributed to its unique morphology and structure. PMID:21779551

2011-07-21

311

Report to Congress on Control of Combined Sewer Overflow in the United States.  

Science.gov (United States)

This report presents by state the status of awarded grants, requested grants, and the estimated time required to achieve required control of combined sewer overflow pollution. It also compares discharges of pollutants from treated municipal effluent with ...

1978-01-01

312

Plasma nitriding of austenitic stainless steel in N_2 and N_2/H_2 gas admixture  

International Nuclear Information System (INIS)

Plasma nitriding in glow discharge is a process of modifying surface properties of a material by which surface hardness, corrosion resistance, fatigue strength etc. of a material can be improved

2004-09-01

313

Monitoring DC partial discharges with Nilsson Plate  

Energy Technology Data Exchange (ETDEWEB)

The Nilsson Plate High Frequency Adaptation of the Static Electrification Monitor developed by Electric Research and Management, Inc. for EPRI has demonstrated that the Nilsson Plate can be utilized as a practical high frequency antenna to record partial discharge activity within a transformer. Tests in the ABB factory at Muncie, IN on a 650 MVA, 345/20.9 kV, three-phase unit step-up transformer for TU Electric showed the Nilsson plate detecting partial discharge activity. Although this test was the first attempt at using the Nilsson plate in this manner, and in spite of higher than expected electrical noise levels, the data demonstrated that partial discharges can be detected. The tests also demonstrated that corona activity external to the transformer was not recorded by the plate. Some development work needs to be completed to eliminate the noise source from other monitors on the Static Electrification monitor, and to ...

1995-05-01

314

MANUAL: COMBINED SEWER OVERFLOW CONTROL  

Science.gov (United States)

This manual provides information to assist in selection and designing control measures for reducing pollutant discharges from combined sewer overflows (CSOs). he manual will be useful for municipal public works staff, design engineers, and regulatory agency staff tasked with the ...

315

J4P Evaluation of Externally Heated Pulsed MPD Thruster Cathodes  

Science.gov (United States)

twenty 350 V, 2.5 mF aluminum electrolytic capacitors with 10.8 mH inductors made of multi-strand wire. The PFN discharge was controlled using an silicon ...

316

Influence of excited molecules on electron swarm transport coefficients and gas discharge kinetics  

Energy Technology Data Exchange (ETDEWEB)

In this paper we study different effects of excited molecules on swarm parameters, electron energy distribution functions and gas discharge modeling. First we discuss a possible experiment in parahydrogen to resolve the discrepancy in hydrogen vibrational excitation cross section data. Negative differential conductivity (NDC) is a kinetic phenomenon which manifests itself in a particular dependence of the drift velocity on E=N and it is affected by superelastic collisions with excited states. A complete kinetic scheme for argon required to model excited state densities in gas discharges is also described. These results are used to explain experiments in capacitively and inductively coupled RF plasmas used for processing. The paper illustrates the application of atomic and molecular collision data, swarm data and the theoretical techniques in modeling of gas discharges with large abundances of excited molecules. It is ...

1997-09-01

317

Influence of duration and rate of pulse rise of the applied voltage on ozone concentration in the barrier glow discharge  

International Nuclear Information System (INIS)

The barrier glow discharge between two planar electrodes, covered with dielectric, is studied under high-voltage pulsed power supply. Wide applications of such type of discharges, in particular, for ozone production, stimulated a number of investigations in this direction. In this work we investigated the dependence of ozone concentration on the duration and the rate of pulse rise of the applied voltage. The thyristor converter circuit with the shortening of input pulses on the base of the saturable throttle was used for the realization of this task. The output pulses with amplitude up to 15 kV, repetition frequency of 1 kHz, pulse duration of 0.3 #mu#s (or 7 #mu#s) and the rate of pulse rise of 0.1 #mu#s were generated with this scheme. Measurements of the ozone concentration produced in the air mixture have shown that its value increased by factor two with variation of the rate of pulse rise from 0.5 #mu#s to 0.1 #mu#s (for pulse duration of ...

2005-09-06

318

General practitioners' immediate management of men presenting with urethral symptoms.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To describe the immediate reported management, by general practitioners (GPs), of men presenting with symptoms of urethral discharge, or dysuria only. SUBJECTS: All 692 GPs in practice in...Full Text Available

1996-12-01

319

Environmental assessment for the ore mining and dressing industry. Final interim report: Revised executive summary  

Energy Technology Data Exchange (ETDEWEB)

The report summarizes the environmental significance of the priority pollutants being discharged from thirteen subcategories of the ore mining and dressing point source category. In addition, the impact of proposed effluent limitations guidelines is assessed from an environmental perspective.

1981-01-23

320

Electrochemical hydrogen storage of ball-milled MmMg{sub 12} alloy-Ni composites  

Energy Technology Data Exchange (ETDEWEB)

MmMg{sub 12}-Ni amorphous or nanocrystalline composites (Mm: Ce-rich mischmetal) were prepared through the ball-milling method, and their electrochemical hydrogen storage performance was investigated and compared with that of ball-milled CeMg{sub 12}-Ni composites. It was found that the ball-milled MmMg{sub 12}-Ni composites had larger initial discharge capacities and better high rate dischargeability. Analysis of electrochemical impedance spectra (EIS) shows that the reaction resistance and hydrogen diffusion resistance of the ball-milled MmMg{sub 12}-Ni composites are lower as a result of the decrease in Ce content, and thus can contribute to the larger discharge capacity and better high rate dischargeability. Additionally, the cycle performance of the ball-milled MmMg{sub 12}-Ni composites is better than those of the ball-milled CeMg{sub 12}-Ni composites. This may be related to the formation of a Nd ...

2010-04-15

321

Effects of atmospheric pressure on tracking failure of organic insulating materials; Yuki zetsuen zairyo no tai tracking sei ni oyobosu kiatsu no eikyo  

Energy Technology Data Exchange (ETDEWEB)

The effect of atmospheric pressure on tracking resistance of organic insulating materials were investigated in the range of 500 to 1007 hPa. The tracking resistance for Polycarbonate (PC), Modified Polyphenylene Oxide (M-PPO) and Paper Base Phenolic Resin Laminate (PL) increase with the decrease in atmospheric pressure. The scintillating discharges on these samples surface lead to the ignition. The tracking failure on these results from the ignition on the surface. For Polybutylene Terephthalate (PBT) and Polyethylene Terephthalate (PET), the tracking resistance decrease with the decrease in atmospheric pressure. The discharges observed on the these surface are the glow-like. The discharge area spreads on the surface between the electrodes at the lower pressure. The failure on this group results from the carbonization by the discharges on the surface. However, the tracking resistance for Unsaturated ...

1995-11-20

322

ESTIMATION OF WATER QUALITY CRITERIA VIOLATION FREQUENCIES USING PEARSON PERCENTILES  

Science.gov (United States)

A numerical technique is developed for estimating water quality violation frequencies due to pollutant discharges from urban areas during combined sewer overflow events. The first four moments of in-stream pollutant concentration are found by integrating a pollutant loading - wat...

323

EARLY BILATERAL SENSORY DEPRIVATION BLOCKS THE DEVELOPMENT OF COINCIDENT DISCHARGE IN RAT BARREL CORTEX  

UK PubMed Central (United Kingdom)

Several theories have proposed a functional role for synchronous neuronal firing in generating the neural code of a sensory perception. Synchronous neural activity develops during a critical...Full Text Available

2009-02-25

324

Decelerating burst and complex repetitive discharges in the striated muscle of the urethral sphincter, associated with urinary retention in women.  

UK PubMed Central (United Kingdom)

A type of electromyographic activity, formerly referred to as "pseudomyotonia", can be recorded from the striated muscle of the urethral sphincter using a concentric needle electrode. There are two...Full Text Available

1985-10-01

325

Characteristics of pulse corona discharge over water surface  

International Nuclear Information System (INIS)

Production of ozone and OH radical is required to advance the plasma chemical reactions in the NOx removal processes for combustion gas treatment. The corona discharge to the water surface is expected to induce the good conditions for the proceeding of the NO oxidation and the NO_2 dissolution removal into water. In order to get the fundamental data of the corona discharge over the water surface, the positive and negative V-I characteristics and the ozone production were measured with the multi needle and the saw-edge type of the discharge electrodes. The pulse corona characteristics were also measured with some different waveforms of the applied pulse voltage. The experiments were carried out under the atmospheric pressure and room temperature. Both the DC and the pulse corona to the water surface showed a stable and almost the same V-I characteristics as to plate electrodes though the surface of water was waved by corona ...

2008-12-01

326

Behavior of ice covers subjected to large daily flow and level fluctuations  

Energy Technology Data Exchange (ETDEWEB)

The stability of a solid ice cover subjected to rapidly varying water levels and discharge was investigated. The support from the bank limits the stress in the ice cover and consequently bank contact must be maintained to ensure ice cover stability. An analysis was required of the stability of ice hinges, a flexible connection between a solid ice cover and the riverbank. Phase II and phase III of the research involved a field study of the Peace River, investigating the evolution of ice hinges with water level variation, from initial ice cover cracking parallel to the banks, to a fully developed hinge. A test program of midwinter discharge variations was undertaken to gather specific data and measurements of ice hinge link length, ice thickness, hinge joint behavior, riverbank geometry, and response of ice hinging to water level variation. This volume of appendices to the study presents detailed observations and comments from field notes through ...

1984-11-01

327

Associations between the clinical signs of chronic endometritis with ovarian cysts and body condition loss in German Holstein Friesian cows  

UK PubMed Central (United Kingdom)

The objective of this retrospective field study was to associate the type and smell of discharge, the size of the uterus, the ovarian and treatment status, and the time to diagnosis of animals with...Full Text Available

2009-12-01

328

Altitude Developmental Testing of the J-2S Rocket Engine in ...  

Science.gov (United States)

... C Characteristic velocity, ft/sec CCP Customer connect panel CD Discharge coefficient EBW Exploding bridgewire vi Page 10. AE DC-TR-70-150 ...

1970-06-01

329

A dry element  

Energy Technology Data Exchange (ETDEWEB)

The agglomerate for the element is made from activated charcoal powder, an electrically conducting additive and a neutral electrolyte. The activated charcoal makes up 30 to 50 percent of the weight of the agglomerate. It is a mixture of hydrophobized and unhydrophobized powder in a ratio of 85 to 70 to 15 to 30. The element has high discharge characteristics.

1983-08-11

330

Water resources data for Oklahoma, water year 1992. Volume 2. Red River Basin. Water-data report (Annual), 1 October 1991-30 September 1992  

Energy Technology Data Exchange (ETDEWEB)

Volume 2 of the water resources data for the 1992 water year for Oklahoma consists of record of stage, discharge, and water quality of streams; stage, contents, and water quality of lakes or reservoirs; and water levels of ground-water well. The report contains discharge records for 136 gaging stations; stage and contents for 31 lakes or reservoirs; water quality for 50 gaging stations. Also included are 61 partial-record or miscellaneous streamflow stations and 28 ground-water sites.

1993-04-01

331

Symmetric Surface Waves in Cylindrical Waveguide Structures Filled by Radially Non-uniform Collisional Plasma  

International Nuclear Information System (INIS)

This report is devoted to the investigation of the influence of electron collisions and radial non-uniformity of plasma density on phase characteristics, spatial attenuation and wave field structure of slow symmetric electromagnetic waves that propagate along cylindrical waveguide structure. It has been shown that collision rate and radial non-uniformity of plasma density for various parameters of waveguide structure and dielectric affect essentially on the wave characteristics and consequently, on the parameters of gas discharge that is sustained by this wave. The results obtained are of large importance for the construction of the theory of gas discharges that are sustained by the surface electromagnetic waves.

2006-01-01

332

Recovery of cesium in the hydrogen negative ion sources  

Energy Technology Data Exchange (ETDEWEB)

Cesium recovery from the polluted layers in the 1/3 scale hydrogen negative ion source for LHD-NBI system has tested. It was found, that the cesium recovery can be produced by additional discharges as from the cesium layer, aged by tungsten and residual gas, so as from the cesium layers, polluted by an occasional water leak. The highest cesium recovery to NI production was produced by a xenon arc, while glow discharge and arcing in hydrogen were less effective. The mechanism of recovery is the ejection of cesium from the underlying enriched layer by the arc and its transport to the surface. (author)

1999-12-01

333

Plasma nitriding of low alloy steels at floating and cathodic potentials  

International Nuclear Information System (INIS)

The low alloy steels were nitrided in the plasma atmosphere generated by using hollow cathode discharge. For comparison, specimens of 40 Cr steel were in two different potential states. One kind is isolated from cathode and anode between them the discharge was created. The other kind is placed on the plate which is connected to the cathode. The nitriding was carried out at different temperatures. The surface morphology, phase of compound layers and microhardness profiles were analyzed. The optical microscopy observation and X-ray diffraction showed that the compound layers were formed in all experiments. The results of the nitriding treatment are weakly dependent on the potentials applied on the specimens.

2008-08-15

334

On-line partial discharge measurements and off-line dielectric spectroscopy measurements of six 115 kV XLPE cable systems  

Energy Technology Data Exchange (ETDEWEB)

This paper reported on a study in which partial discharge (PD) measurements were performed on 6 underground transmission cable circuits to determine the effectiveness of PD measurements on fluid fill cables. The cables were between 37 and 56 years old. PD activity was detected from the terminations of H11L and H3L Cable 2. However, for cables from H3L Basin TS to Mill Street junction, PD activity was detected originating from within the main cable insulation.

2009-07-01

335

Modeling of an electrically rechargeable alkaline zinc-air battery  

Energy Technology Data Exchange (ETDEWEB)

A numerical model has been developed to simulate the charging and discharge behaviour of an electrically rechargeable alkaline zinc-air battery. Further a galvanostatic experiment including three charge/discharge cycles has been performed. The cell voltages, the Zn electrode potentials versus a Zn reference, and the O{sub 2} electrode potentials versus a Zn reference calculated with the model are in fairly good agreement with the corresponding experimental data. The model is expected to be useful for zinc-air battery design and for analysis of experimental data. (author)

2003-03-01

336

Ion-plasma nitriding of the alloyed steel using a low pressure arc plasma generator  

International Nuclear Information System (INIS)

A study is made into microhardness and structure of coatings on various system steels (37G2S, 25Kh5M, R6M5), obtained by ion nitriding in a low pressure (10"-"1 Pa) arc discharge plasma. A comparison of properties is accomplished for steels nitrided in an arc gas discharge and in a furnace. It is stated that ion-plasma nitriding in an arc gas plasma generator is an efficient method of alloy steels hardening which allows changing the structure and increasing the hardness of a surface layer up to rather great depth

2006-12-01

337

Ion nitriding of Armco iron in various glow discharge regions  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the first results of a study of plasma nitriding in various regions of a d.c. glow discharge, i.e. on the cathode, on the anode, and on a substrate isolated from the cathode and anode (at plasma potential). The results obtained reveal differences in the growth kinetics and surface morphology of the nitriding layers, depending on the region where the nitriding process took place. The aim of this work was to study the role of low temperature plasma in the plasma nitriding process. The processes were carried out in an apparatus for plasma treatment with a hot anode. (orig.)

1993-10-01

338

Ion Transport Measurements in a Multi-Dipole Argon Plasma by Broadband Laser Induced Fluorescence  

International Nuclear Information System (INIS)

Argon ion laser induced fluorescence measurements were carried out in a multipolar filament discharge with a broadband diode laser centered on 668 nm, which stimulated a transition from the metastable state in Ar(II) 3d4F7/2 to 4p4D05/2. The intensity of the induced fluorescence at 442 nm was maximized by the optimization of the discharge parameters and the laser power. From the recovery of the background fluorescence after the laser was turned off, the ion diffusion coefficient was deduced and compared with the result inferred from the experiments of ion acoustic wave (IAW) damping.

2009-06-01

339

Generation of microwaves and hard X-rays in a flash X-ray tube  

Energy Technology Data Exchange (ETDEWEB)

High interelectrode voltage peaks have been observed simultaneously with the emission of hard X-ray bursts from a flash X-ray tube. The magnitude of the voltage peaks may exceed twice the initial charging voltage. It has also been observed that the discharge emits bursts of X-and P-band microwaves radiation which are coincident with the emission of the hard X-ray bursts. The results indicate that the microwaves and X-rays have a common origin in discharge plasma movements and an acceleration model for electrons in the plasma is presented as one possible explanation of the observed phenomena.

1982-01-01

340

Electrical properties of airborne nanoparticles produced by a commercial spark-discharge generator  

International Nuclear Information System (INIS)

A nanoparticle generator based on the principle of electrical discharge (PALAS GFG-1000) was used to produce nanoparticles of different chemical natures. The fractions of electrically neutral particles were then measured by means of a Spectrometre de Mobilite Electrique Circulaire (SMEC, i.e. radial-flow mobility analyzer) for different operating conditions. The experimental results were compared with the theoretical values calculated from the Fuchs extended charge equilibrium model for spherical particles and agglomerates. For the smallest particles (below 20 nm), the deviations observed remain below 10%, and tend towards 20% for larger particles (over 35 nm).

2010-08-01

341

Discharging-ionization of tellurium in nitric acid electrolytes in the presence of tartrate ions  

Science.gov (United States)

The authors investigated the influence of tartaric acid, which possesses complex-forming properties. In order to establish the optimum system of possible refinement of tellurium, the authors study the kinetics of both the cathodic and the anodic processes. The investigation of processes of discharging-ionization of tellurium from nitric acid electrolytes in the presence of tartrate ions showed the possibility of preparing a nitric-tartaric acid electrolyte which can be used for commercial purposes and from which a high-purity raffinate was obtained from technical tellurium.

1986-03-20

342

Computer modeling of electrical performance of detonators  

Energy Technology Data Exchange (ETDEWEB)

An empirical model of detonator electrical performance which describes the resistance of the exploding bridgewire (EBW) or exploding foil initiator (EFI or slapper) as a function of energy, deposition will be described. This model features many parameters that can be adjusted to obtain a close fit to experimental data. This has been demonstrated using recent experimental data taken with the cable discharge system located at Sandia National Laboratories. This paper will be a continuation of the paper entitled ``Cable Discharge System for Fundamental Detonator Studies`` presented at the 2nd NASA/DOD/DOE Pyrotechnic Workshop.

1995-05-01

343

Aspiration cover for the loading site of a belt conveyer  

Energy Technology Data Exchange (ETDEWEB)

An aspiration cover is proposed for the site of loading a belt conveyer including a housing arranged above the belt conveyer in whose cover there is an aspiration sleeve and a discharge chute from the upper wall and a guide having a cushioning plate on the lower end. It is distinguished by the fact that in order to improve the effectiveness of removing dust by decreasing the volume of aspirated air, the cover between the aspiration sleeve and the upper wall of the loading chute is convex in the inside of the housing and has a smooth connection to the upper wall of the discharge chute turned towards the cushioning plate.

1982-01-01

344

A marine compartment model for collective dose assessment of liquid radioactive effluents  

International Nuclear Information System (INIS)

A compartment model is described which is currently used by the Ministry of Agriculture, Fisheries and Food to calculate collective radiation exposure due to liquid radioactive wastes discharged to sea from UK nuclear sites. Collective dose is a useful indicator of the radiological impact of a disposal practice and is one of the quantities needed to show compliance with the ICRP system of dose limitation. The model has been used for the purposes of the Sizewell Inquiry to predict the collective radiation exposure from reactor operation at Sizewell and, on the basis of current Sellafield experience, correlations between dose and discharge for disposals of fuel reprocessing wastes. (author).

1982-01-01

345

Wastewater treatment; Abwasserreinigung  

Energy Technology Data Exchange (ETDEWEB)

The methods introduced for the field of cleaning waste water can be classified under various processes. Chemical oxidation is done with ozone, hydrogen peroxide and ultraviolet irradiation with subsequent biological decomposition. Another method is ultra-filtration with recovery of valuable materials or waste water ponds with algae biomass to decompose ammonium compounds, nitrates and phosphates. (EF) [Deutsch] Die auf dem Gebiet der Abwasserreinigung vorgestellten Methoden kann man in verschiedene Verfahren einordnen. Die chemische Oxidation erfolgt mit Ozon, Wasserstoff-Peroxid, UV Bestrahlung und anschliessenden biologischen Abbau. Eine andere Methode ist die Ultrafiltration mit Rueckgewinnung von Wertstoffen oder Abwasserteiche mit Algenbiomasse zum Abbau von Ammoniumverbindungen, Nitraten und Phosphaten. (EF)

1994-11-01

346

U.S. Department of Energy, Nevada Operations Office, Environmental Monitoring Program: Summary data report - first and second calendar quarters 1994  

International Nuclear Information System (INIS)

During the first and second quarters of 1994 air samples were collected and analyzed from 54 air particulate/halogen sampling stations, 10 noble gas sampling stations and 19 tritiated water vapor sampling stations. Surface water samples were collected and analyzed from 12 open water supply reservoirs, 8 natural springs, 2 wastewater containment ponds and 9 sewage lagoons. Groundwater samples were obtained brom 10 potable and 1 non-potable supply wells, and 8 drinking water consumption points. Ambient radiation levels were measured at 193 locations.

1991-10-31

347

The wash-off of dyeings using interstitial water part 1: Initial studies  

British Library Electronic Table of Contents (United Kingdom)

The extent to which a novel wash-off process using polyamide beads removed five different types of dye from three different types of fibre was similar to that achieved using conventional aftertreatments. Whilst bead wash-off and the conventional aftertreatments were of similar duration and temperature, conventional aftertreatment employed a 10:1 or 20:1 liquor ratio whereas bead wash-off used a < 1:1 liquor ratio. As vagrant dye was adsorbed onto the bead material during wash-off, the low amount of wastewater generated contained little residual dye, thereby offering the potential of reduced environmental and cost benefits. Bead wash-off did not impair the fastness of two non-metallised acid dyes on nylon 6,6 to washing at 60 ?C.

2011-01-01

348

Synergies in co-digestion of sludge with olive oil mill effluent  

Energy Technology Data Exchange (ETDEWEB)

A full scale co-digestion system for sludge and Olive oil mill effluent (OME) and a regional sludge management plan has been set-up to solve urgent environmental problems, modifying an existing cold municipal digester, by means of simple and effective technology. Monitoring of the full scale system demonstrated good compatibility between OME and sludge, up to 20% mixture, and high removal of organics compounds. Coagulant compounds present in OME (mainly Fats), promoted aggregation and settling of anaerobic sludge and also its acetoclastic activity, minimizing the load returned to the wastewater treatment line and improving also the activated sludge system. The co-digestion of OME with sludge agreed the project purposes, and produced large quantity of biogas and electric energy.

2004-07-01

349

Submerged microfiltration membrane coupled with alum coagulation/powdered activated carbon adsorption for complete decolorization of reactive dyes  

British Library Electronic Table of Contents (United Kingdom)

Even the presence of very low concentrations of dyes (1mgL-1) in the effluent is highly visible and is considered aesthetically undesirable. It must be removed from wastewater completely. This study systematically evaluates the performance of adsorption (three kinds of powdered activated carbons), coagulation (AlCl36H2O) and membrane (submerged hollow fiber microfiltration) processes individually in treating two kinds of reactive dyes (Orange 16 and Black 5) and then using a hybrid process with combined coagulation-adsorption-membrane treatment system. Adsorption capacity and kinetics of Orange 16 were much higher and faster than those of Black 5. The dye removal efficiency by coagulation was highly dependent on dye concentration and solution pH. The hybrid process performance was far more...

2006-01-01

350

Series of surveys for enteric viruses and indicator organisms in Tokyo Bay after an event of combined sewer overflow.  

Science.gov (United States)

Combined sewer overflows (CSOs) have been recognised as one of the serious sources of pollution to the water environment during rain events, although field surveys to investigate the effect of their magnitude and duration on receiving waters have been very limited. The fates of enteric viruses (norovirus G1, G2, enteroviruses) and coliforms were determined in the wastewater treatment plant on a fine day and on a rainy day. Not all microorganisms were reduced in the primary treatment, but were reduced in the secondary treatment. Occurrences of enteric viruses and levels of coliforms were surveyed in the receiving coastal area after a CSO event, with the profiles of the enteric viruses in the coastal seawater being almost at the same positive ratio for 4 d after the CSO event. PMID:15318519

2004-01-01

351

Removal of reactive dye Brilliant Red HE-3B from aqueous solutions by industrial lignin: Equilibrium and kinetics modeling  

British Library Electronic Table of Contents (United Kingdom)

The lignin, one of the main by-products of the pulp industry, can be used to remove dyes from textile wastewaters. The potential of the lignin for Brilliant Red HE-3B reactive dye removal from aqueous solutions at pH=1.5 was examined by the batch technique as a function of dye concentration, solution temperature and contact time. The Freundlich, Langmuir, Dubinin-Radushkevich and Tempkin adsorption isotherms were used to describe the data of sorption equilibrium and to determine its corresponding isotherm constants. The thermodynamic parameters DG, DH and DS were also determined; the obtained values show that the sorption of reactive dye on lignin is a spontaneous, endothermic and entropy-driven process. The kinetic of reactive dye sorption was analyzed using the pseudo-first order and pse...

2010-01-01

352

Removal of polycyclic aromatic hydrocarbons from aqueous solution using plant residue materials as a biosorbent  

British Library Electronic Table of Contents (United Kingdom)

To elucidate biosorption mechanism and removal efficiency of plant residues as a biosorbent to abate polycyclic aromatic hydrocarbons (PAHs) in wastewater, sorption of PAHs onto wood chips (WC), ryegrass roots (RR), orange peels (OP), bamboo leaves (BL), and pine needles (PN) were investigated. The structural characterization of the biosorbents was analyzed by elemental composition, BET-N2 surface area, and Fourier transform infrared spectroscopy. PAHs sorption to the selected biosorbents were compared and correlated with their structures. Biosorption isotherms fit well with Freundlich equation and the mechanism was dominated by partition process. The magnitude of phenanthrene partition coefficients (Kd) followed the order of PN>BL>OP>RR>WC, ranged from 2484+/-24.24 to 5306+/-92.49L/kg. Ex...

2011-01-01

353

Non-catalytic and catalytic wet air oxidation of pharmaceuticals in ultra-pure and natural waters  

British Library Electronic Table of Contents (United Kingdom)

A wet air oxidation (WAO) process was applied to four selected pharmaceuticals (metoprolol, naproxen, amoxicillin, and phenacetin) individually dissolved in ultra-pure water, varying the temperature and oxygen pressure. Due to the moderate (amoxicillin) or low (metoprolol, naproxen, and phenacetin) efficiency found in the oxidation of these pollutants, a catalytic wet air oxidation (CWAO) process was then tested using a platinum catalyst supported on multi-walled carbon nanotubes (CNT). In this CWAO process, the pharmaceuticals were dissolved together in ultra-pure water and in four natural water matrices-a reservoir water, a groundwater, and two waters from different municipal wastewater treatment plants. On the basis of the measurements of their removals, a discussion is given of the inf...

2011-01-01

354

Kinetics of a reactive dye adsorption onto dolomitic sorbents.  

Science.gov (United States)

A novel wastewater treatment technique has been investigated, for reactive dye removal, in batch kinetic systems. These experimental studies have indicated that charred dolomite has the potential to act as an adsorbent for the removal of Brilliant Red reactive dye from aqueous solution. The effect of initial dye concentration, adsorbent mass:liquid volume ratio, and agitation speed on dye removal have been determined with the experimental data mathematically described using empirical external mass transfer and intra-particle diffusion models. The experimental data show conformity with an adsorption process, with the removal rate heavily dependent on both external mass transfer and intra-particle diffusion. PMID:12691893

2003-05-01

355

Independent power plant using wood waste  

Energy Technology Data Exchange (ETDEWEB)

A 1 MWe power plant using waste wood fuel is to be installed at a US Marine Corps base, which will supply all wood from a landfill site. The core energy conversion technology is a down-draft gasifier supplying approximately 150 Btu/scf gas to both spark ignition and diesel dual-fuel engine-generator sets. Features of the plant design include: (1) grinding wood fuel from a wide range of waste resources, (2) specialized screening for fines removal, (3) complete tar and other waste product control without landfill disposal, and (4) use of process heat for bulk fuel drying, gasifier air pre-heating, and wastewater evaporation.

1995-08-01

356

Diversity of Dominant Bacterial Taxa in Activated Sludge Promotes Functional Resistance following Toxic Shock Loading  

British Library Electronic Table of Contents (United Kingdom)

Examining the relationship between biodiversity and functional stability (resistance and resilience) of activated sludge bacterial communities following disturbance is an important first step towards developing strategies for the design of robust biological wastewater treatment systems. This study investigates the relationship between functional resistance and biodiversity of dominant bacterial taxa by subjecting activated sludge samples, with different levels of biodiversity, to toxic shock loading with cupric sulfate (Cu[II]), 3,5-dichlorophenol (3,5-DCP), or 4-nitrophenol (4-NP). Respirometric batch experiments were performed to determine the functional resistance of activated sludge bacterial community to the three toxicants. Functional resistance was estimated as the 30?min IC50 or th...

2011-01-01

357

Catalytic applications of red mud, an aluminium industry waste. A review  

Energy Technology Data Exchange (ETDEWEB)

Red mud is a by-product of bauxite processing through Bayer process. The amount of red mud generated depends largely on the type of ore used and the processing. Use of red mud as a catalyst can be a good alternative to the existing commercial catalysts. Its properties such as iron content in form of ferric oxide (Fe{sub 2}O{sub 3}), high surface area, sintering resistance, resistance to poisoning and low cost make it an attractive potential catalyst for many reactions. Besides red mud, ferric ion sludge from wastewater treatment plant has also been studied for its catalytic properties, mainly due to its ferric oxide constituent. This paper reviews the studies on red mud as a catalyst. The catalyst characteristics, reaction mechanisms involved and performance are examined and compared with iron oxide catalyst and commercial catalysts. (author)

2008-05-30

358

Biosorption of heavy metals on fungal biomass  

Energy Technology Data Exchange (ETDEWEB)

A method of using fungi in removing heavy metal from wastewater was discussed. Fungi for this purpose can be obtained inexpensively, and on a constant basis from industrial fermentation processes. The biosorption of lead, cadmium and nickel on fungal stock cultures, was investigated. In these experiments, the fungal stock used was Aspergillus niger and Rhizopus stolonfier. Alkali pre-treatment of the fungal biomass improved the metal biosorptive capacity in comparison to live cells. The effect of alkali treatment, however, varied,showing highest biosorptive capacity for lead and least for nickel. Results showed that metal biosorption of metallic ions increased with an increase in pH from 3.2 to 4.0. Equilibrium times of five hours were observed for the biosorption of lead and cadmium, while the equilibrium time for nickel was three hours. 10 refs., 3 tabs., 7 figs.

1996-09-01

359

Biosorption behavior and mechanism of beryllium from aqueous solution by aerobic granule  

British Library Electronic Table of Contents (United Kingdom)

The treatment of Be-contaminated wastewater has been paid little attention, although beryllium (Be) and its compounds are of high toxicity. In this research, aerobic granule was for the first time introduced to remove Be from aqueous solution. Influencing factors including reaction time, initial Be concentration, pH, biosorbent dosage, and coexistent metal ions (Cd, Cu, and Fe) were investigated in batch experiments. The aerobic granule, characterized by element analysis and CLSM, was abundant in carboxyl, phosphoryl, amine and hydroxyl groups. Potentiometric titration experiment demonstrated that the pH effect on biosorption depended on the surface charge of granule (pHzpc=2.4) and the species of Be (Be^2^+, Be(OH)^+, and Be(OH)2) in solution. The coexistent metal ions would either inhibi...

2011-01-01

360

Base flow hydrology and water quality of an Ozarks spring and associated recharge area, southern Missouri, USA  

British Library Electronic Table of Contents (United Kingdom)

Human activities in the karst Ozark Plateaus can impact water quality of springs where surface water is rapidly transferred to subsurface conduits. Bennett Spring, in southern Missouri, is the fourth largest spring in the state and supports local tourism activities. Questions regarding poorly functioning on-site wastewater systems (OWS) have raised concerns over the long-term water quality of the spring. This study reports the results of a surface water quality monitoring program in the recharge area where monthly samples were collected at base flow to identify potential pollution sources to the spring. Base flow hydrology of the recharge area was highly variable over the study period, which was drier than normal, causing an incomplete sampling record due to no flow conditions at some site...

2011-01-01

361

3D model for a secondary facultative pond  

British Library Electronic Table of Contents (United Kingdom)

This paper describes a comprehensive model of wastewater treatment in secondary facultative ponds, which combines 3D hydrodynamics with a mechanistic water quality model. The hydrodynamics are based on the Navier-Stokes equation for incompressible fluids under shallow water and Boussinesq assumptions capturing the flow dynamics along length, breadth and depth of the pond. The water quality sub model is based on the Activated Sludge Model (ASM) concept, describing COD and nutrient removal as function of bacterial growth following Monod kinetics, except for Escherichia coli removal, which was modelled as first order decay. The model was implemented in the Delft3D software and was used to evaluate the effect of wind and the addition of baffles on the water flow pattern, temperature profiles i...

2011-01-01

362

Automation in a material processing/storage facility  

Energy Technology Data Exchange (ETDEWEB)

The Savannah River Site (SRS) is currently developing a new facility, the Actinide Packaging and Storage Facility (APSF), to process and store legacy materials from the United States nuclear stockpile. A variety of materials, with a variety of properties, packaging and handling/storage requirements, will be processed and stored at the facility. Since these materials are hazardous and radioactive, automation will be used to minimize worker exposure. Other benefits derived from automation of the facility include increased throughput capacity and enhanced security. The diversity of materials and packaging geometries to be handled poses challenges to the automation of facility processes. In addition, the nature of the materials to be processed underscores the need for safety, reliability and serviceability. The application of automation in this facility must, ...

1997-05-01

363

Advanced conceptual design report: T Plant secondary containment and leak detection upgrades. Project W-259  

Energy Technology Data Exchange (ETDEWEB)

The T Plant facilities in the 200-West Area of the Hanford site were constructed in the early 1940s to produce nuclear materials in support of national defense activities. T Plant includes the 271-T facility, the 221-T facility, and several support facilities (eg, 2706-T), utilities, and tanks/piping systems. T Plant has been recommended as the primary interim decontamination facility for the Hanford site. Project W-259 will provide capital upgrades to the T Plant facilities to comply with Federal and State of Washington environmental regulations for secondary containment and leak detection. This document provides an advanced conceptual design concept that complies with functional requirements for the T Plant Secondary Containment and Leak Detection upgrades.

1995-05-12

364

Cd(II), Pb(II) and Zn(II) removal from contaminated water by biosorption using activated sludge biomass  

Energy Technology Data Exchange (ETDEWEB)

Biosorption using activated sludge biomass (ASB) as a potentially sustainable technology for the treatment of wastewater containing different metal ions (Cd(II), Pb(II) and Zn(II)) was investigated. ASB metal uptake clearly competed with protons consumed by microbial biomass compared with control tests with non-activated sludge biomass. Biosorption tests confirmed maximum exchange between metal ions and protons at pH 2.0-4.5. It was revealed by the study that the amount of metal ions released from the biomass increased with biomass sludge concentration. The result showed that maximum absorption of metal ions was observed for Cd(II) at pH 3.5, Pb(II) at pH 4.0, and pH 4.5 for Zn(II) ions. The maximum absorption capacities of ASB for Cd(II), Pb(II) and Zn(II) were determined to be 59.3, 68.5 and 86.5%, respectively. The biosorption of heavy metals was directly proportional to ASB stabilization corresponding to a reduction in heavy metals in the order of ...

2010-02-15

365

Application of 'waste' wood-shaving bottom ash for adsorption of azo reactive dye.  

Science.gov (United States)

The utilization of wood-shaving bottom ash (WBA) for the removal of Red Reactive 141 (RR141), an azo reactive dye, was investigated. WBA/H(2)O and WBA/H(2)SO(4) were made by treating WBA with water and 0.1M H(2)SO(4), respectively, to increase adsorption capacity. Adsorption of RR141 from reactive dye solution (RDS) and reactive dye wastewater (RDW) by WBA/H(2)O and WBA/H(2)SO(4) involved the BET surface area and pore size diameter. Properties of adsorbents, effect of contact time, initial pH of solution, dissolved metals and elution studies indicated that the decolorisation mechanism involved both chemical adsorption and precipitation with calcium ions. In addition, the WBA/H(2)SO(4) surface might contain sulphate-cation complexes that were specific to enhancing dye adsorption from RDW. The adsorption isotherm had a best fit by the Freundlich model. Freundlich parameters showed that WBA/H(2)O used more heterogeneous surface than WBA/H(2)SO(4) and activated carbon ...

2008-04-23

366

A study on the development of hypo-stoichiometric Zr-based hydrogen storage alloys with ultra-high capacity for anode material of Ni/MH secondary battery  

Energy Technology Data Exchange (ETDEWEB)

Some hypo-stoichiometric Zr-based Laves phase alloys were prepared and studied from a viewpoint of discharge capacity for electrochemical application. After careful alloy design of ZrMn{sub 2}-based hydrogen storage alloys through changing their stoichiometry while substituting or adding some alloying elements, the Zr(Mn{sub 0.2}V{sub 0.2}Ni{sub 0.6}){sub 1.8} alloy reveals relatively good properties with regard to hydrogen storage capacity, hydrogen equilibrium pressure and electrochemical discharge capacity. In order to improve the discharge capacity and rate-capability, Zr is partially replaced by Ti. The discharge capacity of Zr{sub 1-x}Ti{sub x}(Mn{sub 0.2}V{sub 0.2}Ni{sub 0.6}){sub 1.8} (x=0.0, 0.2, 0.3, 0.4, 0.6) alloy electrodes at 30 C reaches a maximum value and decreases as the Ti fraction increases. In view of electrochemical and thermodynamic characteristics, the occurrence of a maximal ...

2000-08-10

367

Wind Characteristics at the Vawt Test Facility.  

Science.gov (United States)

A limited program of field measurements was undertaken in order to define the wind characteristics of the DOE/Sandia vertical axis wind turbine test facility. Because micrometeorological conditions under which a particular wind turbine is tested may have ...

1978-01-01

368

Use of the fast flux test facility for tritium production  

Energy Technology Data Exchange (ETDEWEB)

This report provides the results of a JASON review of the technical feasibility of using the Department of Energy`s (DOE`s) Fast Flux Test Facility (FFTF) to generate tritium needed for the enduring United States nuclear weapons stockpile.

1996-10-25

369

Solar Cogeneration Facility: Cimarron River Station, Central Telephone and Utilities-Western Power. Executive summary  

Energy Technology Data Exchange (ETDEWEB)

A brief overview of the conceptual design of a solar central receiver system integrated with an existing cogeneration facility is provided. A synopsis of the performance and economic evaluation, and an assessment of the concept from the site owner's perspective are given.

1981-08-07

370

Recent Developments in Coal Liquefaction at the Wilsonville Advanced Coal Liquefaction Research and Development Facility.  

Science.gov (United States)

The results of the two most recently completed runs at the Wilsonville Advanced Coal Liquefaction Research and Development Facility are presented. In Run 255, initial screening of operating conditions for the liquefaction of a Texas lignite was completed....

1991-01-01

371

Pulmonary Alveolar Proteinosis in Workers at an Indium Processing Facility  

UK PubMed Central (United Kingdom)

Two cases of pulmonary alveolar proteinosis, including one death, occurred in workers at a facility producing indium-tin oxide (ITO), a compound used in recent years to make flat panel displays. Both...Full Text Available

2010-03-01

372

Heat Cycle Reserch Experimental Program report, FY-84  

Energy Technology Data Exchange (ETDEWEB)

The Heat Cycle Research Facility (HCRF) is an experimental binary-cycle facility used to investigate different concepts and/or components for generating electrical power from a geothermal resource. This report briefly desc

1984-09-01

373

HPA - Radon Calibration Facilities  

Wastenet

... Radon gas concentrations are measured using instruments with calibrations traceable to the UK National Physical Laboratory and PTB, Germany. The primary facility is a 43 m3 walk-in chamber accessed by an airlock. Radon gas is maintained at a level in this chamber that is ...

374

Energy Engineering Analysis Program, Fort Campbell, Kentucky, energy audit of dining facilities; executive summary. Final report  

Science.gov (United States)

This volume is a summary of the results of the final report of the Energy Engineering Analysis Program (EEAP) Study of 30 selected dining facilities at Fort Campbell, Kentucky.

1986-08-01

375

Decontamination of nuclear facilities  

International Nuclear Information System (INIS)

Thirty-seven papers were presented at this conference in five sessions. Topics covered include regulation, control and consequences of decontamination; decontamination of components and facilities; chemical and non-chemical methods of decontamination; and TMI decontamination experience.

1982-09-19

376

Computer code analysis of steam generator in thermal-hydraulic test facility simulating nuclear power plant.  

Science.gov (United States)

In the study three loss-of-feedwater type experiments which were preformed with the PACTEL facility has been calculated with two computer codes. The purpose of the experiments was to gain information about the behaviour of horizontal steam generator in a ...

1995-01-01

377

33 CFR 148.105 - What must I include in my application?  

Science.gov (United States)

...capacity, and ownership of all planned and existing onshore pipelines, storage facilities, refineries, petrochemical...will be served by the port, including: (i) Onshore pipelines; (ii) Storage facilities; (iii)...

2010-07-01

379

The role of CEMs in DOE thermal treatment  

Energy Technology Data Exchange (ETDEWEB)

The Department of Energy (DOE) currently operates four thermal treatment facilities that are permitted under regulations for hazardous waste combustors. As regulations become more stringent and public stakeholders become more influential, permitting these facilities is increasingly difficult. As they become more available, continuous emission monitors (CEMs) may offer the potential to assure regulators and the public of the safe operation of treatment facilities. The Mixed Waste Focus Area (MWFA) has participated in the development and testing of a variety of CEMs that could have application to DOE facilities.

1998-07-01

380

The Application of Simulation Methods to Intra-Airport ...  

Science.gov (United States)

... Descriptors : *Terminal flight facilities, *Traffic ... Ground support, Queueing theory, Passengers ... Delay, Assessment, Stochastic processes, Ground ...

1975-09-01

381

Selenium - Global Change Master Directory (GCMD)  

Science.gov (United States)

This study is an evaluation of the potential environmental impacts of contaminated groundwater from the ASARCO metals refining facility adjacent to the ...

382
383

Review of ion accelerators  

Energy Technology Data Exchange (ETDEWEB)

The field of ion acceleration to higher energies has grown rapidly in the last years. Many new facilities as well as substantial upgrades of existing facilities have extended the mass and energy range of available beams. Perhaps more significant for the long-term development of the field has been the expansion in the applications of these beams, and the building of facilities dedicated to areas outside of nuclear physics. This review will cover many of these new developments. Emphasis will be placed on accelerators with final energies above 50 MeV/amu. Facilities such as superconducting cyclotrons and storage rings are adequately covered in other review papers, and so will not be covered here.

1990-06-01

384

Results of the 2nd periodical inspection of the asphalt solidification facility and the incinerator in Unit 2 of the Sendai Nuclear Power Station  

International Nuclear Information System (INIS)

The 2nd periodical inspection was carried out on the asphalt solidification facility and the incinerator in Unit 2 of the Sendai Nuclear Power Station from November 5 to 28, 1985. Inspection was made in radiation control facility and disposal facility. By external appearance, disassembly, function and performance tests there were observed no abnormalities. The personnel exposure doses during the inspection were below the permissible level. In the inspection, improvement etc. works were not done. (Mori, K.).

1986-01-01

385

Results of regular inspection of No.2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc  

International Nuclear Information System (INIS)

The regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from January 7 to February 8, 1985. The summary of the results of this regular inspection is as follows. The facilities as the object of inspection were radiation control facilities and waste facilities. On these facilities as the object of inspection, the appearance, disassembling, functional, performance and other inspections were carried out, and as the results, abnormality was not found at all. The works related to this regular inspection were accomplished within the range of the allowable radiation dose based on the relevant laws. (Kako, I.).

1986-01-01

386

PowerPoint Presentation  

Wastenet

facilities, building hygienic latrines and introducing regular solid waste collection systems . These methods are constantly being developed and

387

National Ignition Facility Management Descriptions Revision 4  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this document is to describe the NIF Project Organization and the roles and responsibilities of the managers charged with executing the Project.

2000-08-01

390

Mastery of risks: we build the memory of radioactive waste disposal facilities  

International Nuclear Information System (INIS)

The ANDRA, the French national agency of radioactive wastes, is organizing today the information needs of tomorrow. The aim is to allow the future generations to have access to the knowledge of the existence of subsurface radioactive waste facilities and to understand the context and technologies of such facilities. The storage of this information is made on 'permanent paper', a high resistant paper with a lifetime of 600 to 1000 years. An updating of these data is made every 5 years for each waste disposal center. Another project, still in progress, concerns the memory management of deep geologic waste disposal facilities for which the time scale to be considered is of the order of millennia. (J.S.)

391

Los Alamos DP West Plutonium Facility decontamination project  

Energy Technology Data Exchange (ETDEWEB)

The DP West Plutonium Facility operated by the Los Alamos National Laboratory, Los Alamos, New Mexico, was decontaminated between April 1978 and April 1981. The facility was constructed in 1944 to 1945 to produce plutonium metal and fabricate parts for nuclear weapons. It was continually used as a plutonium processing and research facility until mid-1978. Decontamination operations included dismantling and removing gloveboxes and conveyor tunnels; removing process systems, utilities, and exhaust ducts; and decontaminating all remaining surfaces. This report describes glovebox and conveyor tunnel separations, decontamination techniques, health and safety considerations, waste management procedures, and costs of the operation.

1982-01-01

392

Handbook: Approaches for the Remediation of Federal Facility ...  

Science.gov (United States)

... 4-4 UXO disposal operations ... testing of sequencing batch reactor treatment of ... and lead toward the anode compartment ..... ...

1993-09-01

393

Energy and Water Conservation  

Science.gov (United States)

Jet Propulsion Laboratory. California Institute of Technology. Pasadena, California. Energy and Water Conservation. Steve Rigdon. Facilities Energy Manager ...

394

Energy Engineering Analysis Program (EEAP), Cornhusker ...  

Science.gov (United States)

... is to develop a systematic program of energy consumption reductions in compliance with the stated goals of the Army Facilities Energy Plan (AFEP ...

1984-03-01

395

Energy Engineering Analysis (EEA) Program, Europe. ...  

Science.gov (United States)

... projects that will result in the reduction of energy consumption in compliance with the objectives set forth in the Army Facilities Energy Plan, without ...

1983-07-01

396

Details - Night Sky Network - NASA  

Science.gov (United States)

General Meeting: NASA's biggest challenge: Education ... Turn right into the Police Association Facility at the crest of the first hill. ...

397

DOE reports on feasibility of generic oil shale test facility  

Energy Technology Data Exchange (ETDEWEB)

In order to assess whether an oil shale test facility would be of significant use to private sector oil shale developers, the US DOE has studied the past history of oil shale development and its potential for replacing petroleum supplies. A generic test facility's primary function would be to test concepts of mining, retorting, upgrading, and environmental aspects at the engineering scale. This paper summarizes the US oil shale resources, gives a technology analysis, and discusses the potential for a test facility.

1987-03-01

398

Crisis communication on nuclear facilities and addressing media  

International Nuclear Information System (INIS)

Japanese May 2009 p. 386-390 Japan Mitani, Shinji Japan Nuclear Energy

2009-05-01

399

Modelling transport of water and solutes in future wetlands in Forsmark  

Energy Technology Data Exchange (ETDEWEB)

The Forsmark area consists of a number of natural wetlands. As a part of the evaluation of wetlands in the safety assessment for the area, possible future wetlands are being studied with respect to hydrology and transport mechanisms. A sensitivity analyses is performed to point out the governing parameters for the wetland hydraulics. The analysis of future wetlands is carried out using the hydrological model system Mike SHE. Mike SHE has been used to describe the near-surface hydrology for a regional model area in Forsmark. Three types of areas have been chosen. Today's lake Bolundfjaerden is because of its shallow depth likely to develop into a mire in the future. As it is situated in the downstream part of the regional model area, the runoff to the lake from upstream surface water system is significant. Lake Eckarfjaerden is situated in the upstream part of the catchment at a higher altitude and with a smaller inflow. Lake Puttan is situated above a planned layout of the ...

2006-03-15

400

Project quality assurance plant: Sodium storage facility, project F-031  

International Nuclear Information System (INIS)

The Sodium Storage Facility Project Quality Assurance Plan delineates the quality assurance requirements for construction of a new facility, modifications to the sodium storage tanks, and tie-ins to the FFTF Plant. This plan provides direction for the types of verifications necessary to satisfy the functional requirements within the project scope and applicable regulatory requirements determined in the Project Functional Design Criteria (FDC), WHC-SD-FF-FDC-009.

401

Neptunium storage at Hanford  

Energy Technology Data Exchange (ETDEWEB)

A decision must be made regarding whether the United State`s stockpile of neptunium should be discarded into the waste stream or kept for the production of Pu-238. Although the cost of long term storage is not inconsequential, to dispose of the material means the closing of our option to maintain control over our Pu-238 stockpile. Within the Fuels and Materials Examination Facility at Hanford there exists a remotely operated facility that can be converted for neptunium storage. This paper describes the facility and the anticipated handling requirements.

1993-06-01

402

Natural radioactive materials occurrence in oil facilities  

International Nuclear Information System (INIS)

This work presents and describes the natural radioactive occurrence in oil facilities. The origins of the detected radioactivity and the reasons of its settlement are discussed. The measurements results carried out in oil facilities in the Neuquina basin (Argentine) are shown in this work. The aim is to describe the actual situation and to evaluate the magnitude of the problem. Finally, recommendations are proposed to protect the health of the workers, especially of those who carry out the cleaning of the equipment, and to guarantee an appropriate final disposal for the generated radioactive residuals. (author)

2001-06-01

403

High-explosives test facility  

Energy Technology Data Exchange (ETDEWEB)

This report describes a high explosives test facility that makes efficient use of equipment and combines utility, convenience, and safety in a modest amount of space. It is a dedicated facility for exploratory development efforts that previously were conducted in a single room having very limited capabilities. Two explosives testing areas are now available and several projects are supported concurrently.

1982-08-01

404

FLASH-the first soft x-ray free electron laser (FEL) user facility  

Energy Technology Data Exchange (ETDEWEB)

The free electron laser (FEL) FLASH at DESY in Hamburg is the first x-ray FEL ever built. Many new developments were necessary in order to exploit the unique properties of this novel light source for scientific experiments. The facility has constantly been improved and several major upgrades have been made or are currently underway. This paper reviews the main characteristics of the user facility as well as the major developments and upgrades.

2010-10-14

405

Demonstration of neutron radiography and computed tomography at the University of Texas thermal neutron imaging facility  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere.

1999-09-01

406

Demonstration of neutron radiography and computed tomography at the University of Texas thermal neutron imaging facility  

International Nuclear Information System (INIS)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere

1999-06-06

407

Cold regions hydrology and hydraulics  

Energy Technology Data Exchange (ETDEWEB)

This monograph addresses a narrow aspect of cold regions engineering, namely the effects of cold weather on the traditional civil engineering disciplines of hydrology and hydraulics. Hydrologic and hydraulic considerations in the design, construction, and operation of civil works are very important. Many of the problems encountered in the design and construction of buildings, transportation systems, water supply facilities, waste treatment facilities, and hazardous waste disposal facilities, for example are closely tied to the characteristics of the site hydrology.

1990-01-01

408

About technical possibility to use VEERA facility for investigation of coolant stratification phenomenon in horizontal steam generators  

Energy Technology Data Exchange (ETDEWEB)

The presentation gives a brief insight on possibility of using the VEERA facility in studying the stratification phenomenon. The idea for such experiments is to use the facility upper plenum part to simulate the conditions in upper part of horizontal steam generator hot collector. The upper part of steam generator hot collector is one of the locations where the stratification can take part during natural circulation mode. 4 refs.

1997-12-31

409

Solid state secondary battery with lithium ion conductive solid electrolyte, Li3PO4-Li2S-SiS2; Li3PO4-Li2S-SiS2 kei kotai denkaishitsu wo mochiita zenkotai richiumu niji denchi  

Energy Technology Data Exchange (ETDEWEB)

Powder mold type solid state battery was fabricated, and positive electrode compounding ratio and the battery characteristics were studied. The current density depended greatly on the TiS2 content of positive electrode material, and the current density showed maximum value of 800 {mu}A/cm{sup 2} at a TiS2 content of 40 wt%. This composition is expected to be the best to provide better charge-discharge characteristics. The rate capability of TiS2 is dominated by Li{sup +} ion in positive electrode. Further, the diffusion of lithium ion is greatly dominated by TiS2 in positive electrode, compounding ratio of solid state electrolyte and its particle size. Results of charge-discharge characteristics studied for various charge-discharge current densities revealed that the rate capability of TiS2 was more than 50% for a current density of less than 254 {mu}A/cm{sup 2}, and this battery system proved the possibility of high rate ...

1995-01-05

410

Radiant emittance of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

An embodiment of a mercury-free fluorescent lamp combines a low pressure rare gas discharges with a phosphor having a quantum efficiency grater than one. The choice of the rare gas depends on a number of factors, one of which is the resonance transition energy. Less demand is placed the quantum efficiency of the phosphor for a lower energy resonance photon. Xenon has the lowest energy resonance transition of the stable rare gases at 8.5 eV (147 nm) and thus is a good candidate to study. The usefulness of a xenon-based discharge depends on the radiant emittance of the discharge at the resonance wavelength of 147 nm. The radiant emittance from a low pressure xenon positive column discharge is measured using two independent techniques. The first relies on the measurement of the resonance level density using absorption techniques. The effective decay rate of the resonance level is calculated using radiation ...

1994-12-31

411

Properties of surface layers on titanium alloy produced by thermo- chemical treatments under glow discharge conditions  

Energy Technology Data Exchange (ETDEWEB)

The recent rapid progress in surface treatment techniques dictates that the titanium alloys should have an improved resistance to frictional wear without any loss of their high corrosion resistance. These requirements can be satisfied by producing surface layers of specified microstructure and phase composition. The present paper describes a modification of the plasma discharge nitriding treatment of titanium alloys, i.e. the glow discharge-assisted oxycarbonitriding, which by introducing oxygen, nitrogen and carbon into the surface zone of the layer [a Ti(NCO) type layer] improves its useful properties, primarily the resistance to frictional wear and the resistance to corrosion [T. Wierzchon, J. Sobiecki, Vacuum, 44 (1993) 975; T. Wierzchon et al., in: G. Hecht, F. Richter, J. Hahn (Eds.), Thin Films, DGM Informationgesellschaft, Germany, 1994, p. 195] [1:2]. This is because titanium shows a good affinity to oxygen, carbon and nitrogen, ...

1997-11-25

412

Impact assessment using 25 years of environmental radioactivity monitoring data at Tarapur Maharashtra site  

International Nuclear Information System (INIS)

Environmental Survey Laboratory at Tarapur, Maharashtra site carries out environmental radioactivity measurements in different matrices to evaluate the impact of operating nuclear installations. In this paper, the evaluation of data of 1983-2007 (25 years) is presented. Time trends of particulate radioactivity, correlation between "1"3"7Cs in discharge canal seawater and station discharged activity and correlation of "1"3"7Cs, "6"0Co, and "1"3"1I in marine species like Sponge and Nerita and corresponding discharged activity were carried out. Statistical analysis of environmental data of seawater and marine fish for several radionuclides, for distributions, showed that the data best fits lognormal distribution. A strong correlation between "1"3"7Cs in seawater and "1"3"7Cs in liquid waste discharge was observed (R"2 = 0.8, P = 0.000). Similarly correlation was very good for Nerita and ...

2008-07-16

413

An investigation of the origin of the electrochemical hydrogen storage capacities of the ball-milled Co-Si composites  

Energy Technology Data Exchange (ETDEWEB)

The Co-Si composites with a molar ratio of 2:1 are synthesized by ball-milling method and their potential as negative electrode materials of Ni-MH batteries is investigated. The microstructure, morphology and chemical state of the ball-milled Co-Si composites are characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM) and X-ray photoelectron spectroscopy (XPS). XRD patterns show that the ball-milled samples for 10 and 20 h contain Co, Si and Co{sub 2}Si phases, and the ball-milled samples for 40 and 60 h are mainly amorphous Co{sub 2}Si alloys. In contrast to the high initial discharge capacity (1012 mAh/g) obtained for the sample ball-milled for 10 h, the discharge capacities of the samples ball-milled for 40 and 60 h are very low. It indicates that the hydrogen storage capacity of pure Co{sub 2}Si alloy is very low. It is found that the formation of active Co nanoparticles and Si oxidation are responsible for the high ...

2010-02-15

414

Waste Receiving and Processing Facility Module 2A: Advanced Conceptual Design Report. Volume 1  

Energy Technology Data Exchange (ETDEWEB)

This ACDR was performed following completed of the Conceptual Design Report in July 1992; the work encompassed August 1992 to January 1994. Mission of the WRAP Module 2A facility is to receive, process, package, certify, and ship for permanent burial at the Hanford site disposal facilities the Category 1 and 3 contact handled low-level radioactive mixed wastes that are currently in retrievable storage at Hanford and are forecast to be generated over the next 30 years by Hanford, and waste to be shipped to Hanford from about DOE sites. This volume provides an introduction to the ACDR process and the scope of the task along with a project summary of the facility, treatment technologies, cost, and schedule. Major areas of departure from the CDR are highlighted. Descriptions of the facility layout and operations are included.

1994-03-01

415

High-energy x-ray microscopy techniques for laser-fusion plasma research at the National Ignition Facility  

Energy Technology Data Exchange (ETDEWEB)

Multi-kilo-electron-volt x-ray microscopy will be an important laser-produced plasma diagnostic at future megajoule facilities such as the National Ignition Facility (NIF). However, laser energies and plasma characteristics imply that x-ray microscopy will be more challenging at NIF than at existing facilities. We use analytical estimates and numerical ray tracing to investigate several instrumentation options in detail, and we conclude that near-normal-incidence single spherical or toroidal crystals may offer the best general solution for high-energy x-ray microscopy at NIF and similar large facilities. Apertured Kirkpatrick{endash}Baez microscopes using multilayer mirrors may also be good options, particularly for applications requiring one-dimensional imaging over narrow fields of view. {copyright} 1998 Optical Society of America

1998-04-01

416

Development of electronic imaging system for real time neutron radiography at TRIGA MK-II research reactor of AERE, Savar, Dhaka and utilization for research and industrial applications  

International Nuclear Information System (INIS)

The neutron radiography facility was installed at the tangential beam port of the 3 MW TRIGA MARK-II research reactor. In the facility only direct film neutron radiography method is being used. The project involves development of electronic imaging system for real time neutron radiography in the existing facility with the aim of utilizing it for research and industrial applications. In establishing the electronic imaging system for real time neutron radiography the improvements of existing facility were almost done during this period. In parallel, the former facility was used for the research: (a) A study of wood and wood plastic composites with and without additive by using film neutron radiography and (b) A study of jute reinforced polymer composites by using film neutron radiography technique. (author)

2008-09-01

417

Decree of the Czechoslovak Atomic Energy Commission No. 436/1990 on quality assurance of selected facilities with respect to nuclear safety of nuclear facilities  

International Nuclear Information System (INIS)

The Decree specifies basic quality assurance requirements applicable to machines, their parts and materials, civil engineering structures, means for automated control of technological processes including hardware and software, and electricity supply systems related to nuclear safety of nuclear facilities, and stipulates binding procedures for the implementation of technical and organizational provisions associated with the quality of selected equipment to ensure nuclear safety of nuclear facilities. Safety classes are defined for selected equipment. Requirements laid on safety assurance documentation are specified, and requirements placed on safety assurance programmes, their preparation, finalization and approval are defined. Quality assurance requirements are also specified with respect to the designing, manufacture, construction, operation, repair, modification and decommissioning of nuclear facilities. The Decree ...

1995-02-01

418

Water resources data for Texas, water year 1993. Volume 3. Colorado River basin, Lavaca River basin, Guadalupe River basin, Nueces River basin, Rio Grande basin, and intervening coastal basins. Water-data report (Annual), 1 October 1992-30 September 1993  

Energy Technology Data Exchange (ETDEWEB)

Water-resources data for the 1993 water year for Texas are presented in four volumes, and consist of records of stage, discharge, and water quality of streams and canals; and stage, contents, and water quality of lakes and reservoirs; and water levels and water quality of ground-water wells. Volume 3 contains records for water discharge at 134 gaging stations; stage only at 1 gaging stations; stage and contents at 13 lakes and reservoirs; water quality at 81 gaging stations; and data for 30 partial-record and 4 flood-hydrograph partial-record stations. Also included are lists of discontinued surface-water discharge or stage-only stations and discontinued surface-water-quality stations; crest-stage and flood-hydrograph partial-record stations, reconnaissance partial-record stations, and low-flow partial-record stations.

1994-03-01

419

Time-resolved Fourier transform emission spectroscopy of A2P-X2+ infrared transition of the CN radical  

British Library Electronic Table of Contents (United Kingdom)

The A2P-X2+Dv=-3 bands of the 12C14N radical have been observed by time-resolved Fourier transform spectroscopy in the 1850-3100cm-1 region with a wavenumber resolution of 0.025cm-1. The radical was produced in a pulsed positive column discharge in a cyanogene and helium mixture. Seven bands of v=0-3, 1-4, 2-5, 3-6, 4-7, 5-8, and 6-9 were analyzed to give the molecular constants of each state by least-squares fitting of 801 lines. The pulsed discharge was found to be efficient for production of CN in the excited A2P state. The vibrational excitation temperature was determined to be 6680+-835K and 6757+-534K for the A2P and X2+ states, respectively. The population of the A2P was found to be 4% of that of the X2+ state in the time after turning off the discharge.

2008-01-01

420

Single-Electrode Transient Behavior for Electric Double Layer Capacitor Composed of Nano-Porous Carbon Electrode; Kasseitan denki 2jyuso kyapasita no tankyoku jyuhoden katei ni taisuru sokudoronteki kento  

Energy Technology Data Exchange (ETDEWEB)

Single-electrode transient behavior was measured mainly during the discharging process for a model cell of electric double layer capacitor with nano-porous carbon electrodes and reference electrode. Apparent conductivity in the cell, which we call `effective conductivity,` is determined with approximation of current in transient behavior to a one-dimensional electrophoretic model. A comparison of effective conductivity with conductivity of bulk solution suggests an interesting mechanism of transfer of electrolyte ions. The difference in transient behavior between various electrolyte ions was not conspicuous in spite of distinctive differences in conductivity of each bulk solution. The large pore diameter of the carbon electrode results in rapid transient behavior and such an electrode should be suitable for rapid charge and discharge. The effect of origin of carbon electrode is found to be significant to bring considerable differences in ...

1997-07-10

421

Residential runoff as a source of pyrethroid pesticides to urban creeks.  

Science.gov (United States)

Pyrethroid pesticides occur in urban creek sediments at concentrations acutely toxic to sensitive aquatic life. To better understand the source of these residues, runoff from residential neighborhoods around Sacramento, California was monitored over the course of a year. Pyrethroids were present in every sample. Bifenthrin, found at up to 73 ng/L in the water and 1211 ng/g on suspended sediment, was the pyrethroid of greatest toxicological concern, with cypermethrin and cyfluthrin of secondary concern. The bifenthrin could have originated either from use by consumers or professional pest controllers, though the seasonal pattern of discharge from the drain was more consistent with professional use as the dominant source. Stormwater runoff was more important than dry season irrigation runoff in transporting pyrethroids to urban creeks. A single intense storm was capable of discharging as much bifenthrin to an urban creek in 3h as that ...

2008-08-03

422

Residential runoff as a source of pyrethroid pesticides to urban creeks  

International Nuclear Information System (INIS)

Pyrethroid pesticides occur in urban creek sediments at concentrations acutely toxic to sensitive aquatic life. To better understand the source of these residues, runoff from residential neighborhoods around Sacramento, California was monitored over the course of a year. Pyrethroids were present in every sample. Bifenthrin, found at up to 73 ng/L in the water and 1211 ng/g on suspended sediment, was the pyrethroid of greatest toxicological concern, with cypermethrin and cyfluthrin of secondary concern. The bifenthrin could have originated either from use by consumers or professional pest controllers, though the seasonal pattern of discharge from the drain was more consistent with professional use as the dominant source. Stormwater runoff was more important than dry season irrigation runoff in transporting pyrethroids to urban creeks. A single intense storm was capable of discharging as much bifenthrin to an urban creek in 3 h as that ...

2009-01-01

423

Plasma chemistry in wire chambers  

Energy Technology Data Exchange (ETDEWEB)

The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an {sup 55}Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For all gases tested except those containing methane, use of ...

1990-05-01

424

Planar excilamp on rare gas chlorides pumped by a transverse self-sustained discharge  

Science.gov (United States)

The design and parameters of a UV-VUV spontaneous radiation source - an excilamp operating on chlorides of rare gases ArCl{sup *}, KrCl{sup *} and XeCl{sup *} in the wavelength range 175-308 nm are presented. The Ne-Xe(Kr, Ar)-HCl mixtures were excited by a high-pressure self-sustained discharge with spark preionisation. It is shown that upon pumping mixtures of rare gases and halogens by a transverse discharge, the intensities of the B-X emission band of molecules ArCl{sup *}, KrCl{sup *} and XeCl{sup *} are comparable and up to 90% of the emission energy of excilamps can be concentrated in the UV region. The peak UV power density at 222 and 308 nm on the output window of the excilamp was {approx}2 kW cm{sup -2} for the pulse energy up to {approx} 3 mJ. The output emission energy of the excilamp at 175 nm achieved {approx}0.6 mJ and the peak power density was {approx}0.4 kW cm{sup -2}. (laser applications and other topics in quantum ...

2006-02-28

425

Modelling discharges in electronegative gases  

Energy Technology Data Exchange (ETDEWEB)

This paper builds on earlier work to give a consistent treatment of the positive column of discharges in electronegative gases covering the transition from collisionless to collisional. In particular it seeks to elucidate the conditions under which there is an ion-ion plasma core surrounded by an electron-ion plasma, and when there is not. The parameters which describe the processes of ionization, attachment, detachment and recombination are related to the central negative ion density relative to the electron density and, where appropriate, the size of the core. The use, by earlier workers, of the Boltzmann approximation to describe the negative ion distribution and to obtain ambipolar diffusion coefficients at higher pressures is shown not to be justified. This leads to the clarification of an inconsistency in the literature. Where possible, the work is related to other recent treatments of the same problem in order to begin to build a comprehensive picture of ...

1999-09-07

426

Long-lived radionuclides in the coastal sediments of the Irish Sea, UK  

Energy Technology Data Exchange (ETDEWEB)

Over the last four decades the Irish Sea has received controlled discharges of radioactive effluents from the Sellafield (Windscale) nuclear fuel reprocessing plant in Cumbria, UK. Enhanced levels of a range of fission, activation and transuranic elements have been reported in a variety of environmental media. Most of the {sup 239,240}Pu and {sup 241}Am and about 10% of the {sup 137}Cs have been retained in a deposit of the fine sediment near the discharge point. The quantities of radionuclides discharged annually from Sellafield decreased by two orders of magnitude from the mid-1970s to 1990, but estimated critical group internal and external exposure decreased by less than one order of magnitude over this period. Redistribution of the contaminated marine sediment is potentially of major significance. In this paper, a review is presented of published work and recent our study relating to Sellafield waste long-lived ...

1996-12-01

427

Comparison of plasma chemistries for inductively coupled plasma etching of InGaAlP alloys  

International Nuclear Information System (INIS)

Two plasma chemistries, i.e., CH_4/H_2/Ar and Cl_2/Ar, were compared for the etching of InGaP, AlInP, and AlGaP under inductively coupled plasma (ICP) conditions. While the etching with CH_4/H_2/Ar discharges appears to be ion driven, Cl_2/Ar discharges showed an additional strong chemical enhancement. The highest etch rate (#approx#1 #mu#m/min) for InGaP was achieved at high ICP source power (#>=#750 W) with the Cl_2/Ar chemistry. Cl_2/Ar discharges provided very smooth surfaces in all three materials with root-mean-square roughness measured by atomic force microscopy around 2 nm. This result may be due to the efficient ion-assisted product desorption in this chemistry. The etched near-surface region of InGaP (#approx#100 Angstrom) with Cl_2/Ar maintained almost the same stoichiometry as that of the unetched control. By contrast, the CH_4/H_2/Ar plasma chemistry produced somewhat rougher surfaces and depletion of ...

1998-05-01

428

Basic study on high performance secondary battery for electric load-leveling & electric vehicle  

Energy Technology Data Exchange (ETDEWEB)

Na/S battery can have the higher energy density and higher power density than that of existing high performance secondary battery. This battery is expected to use for electric load leveling and electric vehicle. Ni/MH battery was developed in advanced countries, but it is one of the advanced technologies which are preserved in their own country. In the study on Na/S battery, properties of B{sup -}alumina electrolyte was investigated. Also the construction technologies of this test cell was established by combining tube type of B{sup -}alumina solid electrolyte with Na-, S- electrode etc. Especially of this cell, charge/discharge performance and open circuit voltage was examined. Mi/MH battery sample were tested with SBT500 system for self-discharge rate at room temp, was measured. It was found that the electrolyte and separator can be optimized to minimize the self-discharge rate. (author). refs., figs., tabs.

1993-12-01

429

An evaluation of the ecological consequences of partial-power operation of the K Reactor, SRS  

International Nuclear Information System (INIS)

The K Reactor at the Savannah River Site (SRS) shut-down in spring 1988 for maintenance and safety upgrades. Since that time the receiving stream for thermal effluent, Indian Grave Branch and Pen Branch, have undergone a pattern of post-thermal recovery that is typical of other SRS streams following removal of thermal stress. Divesity of fish and aquatic macroinvertebrate communities has increased and available habitats have been colonized by numerous species of herbaceous and woody plants. K Reactor is scheduled to resume operation in 1991 and operate through 1992 without a cooling tower to cool the discharge. It is likely that the reactor will operate at approximately one-third to one-half of full power (800--1200 MW thermal) during this period and effluent temperatures will be substantially lower than earlier operation at full power. Monthly average discharge temperatures at half-power operation will range from approximately 42 degrees C in ...

430

Facilities Condition and Hazards Assessment for Materials and Fuel Complex Facilities MFC-799, 799A, and 770C  

Energy Technology Data Exchange (ETDEWEB)

The Materials & Fuel Complex (MFC) facilities 799 Sodium Processing Facility (a single building consisting of two areas: the Sodium Process Area (SPA) and the Carbonate Process Area (CPA), 799A Caustic Storage Area, and 770C Nuclear Calibration Laboratory have been declared excess to future Department of Energy mission requirements. Transfer of these facilities from Nuclear Energy to Environmental Management, and an associated schedule for doing so, have been agreed upon by the two offices. The prerequisites for this transfer to occur are the removal of nonexcess materials and chemical inventory, deinventory of the calibration source in MFC-770C, and the rerouting and/or isolation of utility and service systems. This report provides a description of the current physical condition and any hazards (material, chemical, nuclear or occupational) that may be associated with past operations of these ...

2009-11-01

431

Results of 1st regular inspection of No.2 unit in Sendai Nuclear Power Plant  

International Nuclear Information System (INIS)

This report presents results of the 1st regular inspection of the No.2 unit of the Sendai Nuclear Power Plant. It was carried out during the period from September 22, 1986, to December 24, 1986. The inspection covered the main unit of the nuclear reactor, facilities for the nuclear reactor cooling system, facilities for the instrumentation control system, fuel facilities, radiation control facilities, disposal facilities, nuclear reactor containment facilities, and emergency power generation system. Checking of appearance, disassemblage, leak and functions-performance of these facilities was conducted and no abnormalities were found. All operations involved in the inspection were performed under conditions within the permissible dose as specified in the applicable laws. No major modification work was carried out during the period of the ...

1987-01-01

432

Results of 1st regular inspection of No. 2 unit in Sendai Nuclear Power Plant  

Energy Technology Data Exchange (ETDEWEB)

This report presents results of the 1st regular inspection of the No. 2 unit of the Sendai Nuclear Power Plant. It was carried out during the period from September 22, 1986, to December 24, 1986. The inspection covered the main unit of the nuclear reactor, facilities for the nuclear reactor cooling system, facilities for the instrumentation control system, fuel facilities, radiation control facilities, disposal facilities, nuclear reactor containment facilities, and emergency power generation system. Checking of appearance, disassemblage, leak and functions-performance of these facilities was conducted and no abnormalities were found. All operations involved in the inspection were performed under conditions within the permissible dose as specified in the applicable laws. No major modification work was carried out during the period of the ...

1987-09-01

433

Preparation of high burnup fuel post-irradiation testing facility  

Energy Technology Data Exchange (ETDEWEB)

In the fuel testing facilities of Japan Atomic Energy Research Institute, the post-irradiation test of practical fuel used in nuclear power stations was begun in December, 1979, and the soundness of practical fuel has been confirmed, and the valuable post-irradiation test data on the behavior of fuel have been acquired. Recently, the heightening of fuel burnup has been advanced, and also in fuel testing facilities, the development and preparation of the post-irradiation testing facility required for examining in detail high burnup fuel have been carried out. The course of the installation of the post-irradiation testing facility and the outline of the facility are reported. As the preparation of the post-irradiation testing facility for high burnup fuel, a hyperfine hardness tester that measures dynamic hardness, the measuring instrument for pellet thermal ...

1996-05-01

434

Managing system for mounted parts and spare parts of power source facilities  

Energy Technology Data Exchange (ETDEWEB)

The power source facilities of JT-60 consist of poloidal magnetic coil power source, toroidal magnetic coil power source, the power generation facility for heating, operation power distribution facility and secondary cooling facility, and at the time of the experiment operation of JT-60, they supply 1300 MVA of instantaneous maximum power to loads. The component machinery and equipment of the power source facilities are installed in about 20 indoor and outdoor places, and their mounted parts are about 15,000 kinds. About 3,000 kinds of spare parts are preserved in 15 exclusively used stores. The managing system for mounted parts and spare parts of JT-60 power source facilities which possesses the functions of rapidly and efficiently carrying out the storage of large quantity of information, mutual relating and retrieval by making mounted parts and spare parts ...

1995-07-01

435

Water resources data for Minnesota, water year 1993. Volume 2. Upper Mississippi and Missouri River basins. Water-data report (Annual), 1 October 1992-30 September 1993  

Energy Technology Data Exchange (ETDEWEB)

Water-resources data for the 1993 water year for Minnesota consists of records of stage, discharge and water quality of streams; stage, contents, and water quality of lakes and reservoirs; and water levels and water quality in wells and springs. This volume contains discharge records for 58 gaging stations; stage and contents for 9 lakes and reservoirs; water quality 15 stream stations, 1 lakes station, 1 precipitation station, and water levels for 15 observation wells. Also included are 61 high-flow partial-record stations. Additional water data were collected at various sites, not part of the systematic data collection program and are pulished as miscellaneous measurements.

1994-07-01

436

Water resources data for Minnesota, water year 1991. Volume 2. Upper Mississippi and Missouri River Basins. Water-data report (Annual), 1 October 1990-30 September 1991  

Energy Technology Data Exchange (ETDEWEB)

Water-resources data for the 1991 water year for Minnesota consist of records of stage, discharge and water quality of streams; stage, contents, and water quality of lakes and reservoirs; and water levels and water quality in wells and springs. The volume contains discharge records for 60 gaging stations; stage and contents for 9 lakes and reservoirs; water quality for 18 stream stations, 1 lake station, 22 partial-record sites, 1 precipitation station, 108 wells; and water levels for 119 observation wells. Also included are 59 high-flow partial-record stations. Additional water data were collected at various sites, not part of the systematic data collection program and are published as miscellaneous measurements or low-flow investigations.

1992-09-01

437

Waste treatment process for removal of contaminants from aqueous, mixed-waste solutions using sequential chemical treatment and crossflow microfiltration, followed by dewatering  

Energy Technology Data Exchange (ETDEWEB)

It is an object of the claimed invention to combine chemical treatment with microfiltration process to treat groundwater, leachate from contaminated soil washing, surface and run-off waters contaminated with toxic metals, radionuclides and trace amounts of organics from variety of sources. The process can also be used to treat effluents from industrial processes such as discharges associated with smelting, mining and refining operations. Influent contaminants amenable to treatment are from a few mg/L to hundreds of mg/L. By selecting appropriate precipitation, ion exchange and adsorption agents and conditions, efficiencies greater than 99.9 percent can be achieved for removal of contaminants. The filtered water for discharge can be targeted with either an order of magnitude greater or lower than contaminant levels for drinking water.

1992-12-31

438

Underground Test Area Subproject Phase I Data Analysis Task. Volume III - Groundwater Recharge and Discharge Data Documentation Package  

Energy Technology Data Exchange (ETDEWEB)

Volume III of the documentation for the Phase I Data Analysis Task performed in support of the current Regional Flow Model, Transport Model, and Risk Assessment for the Nevada Test Site Underground Test Area Subproject contains the data covering groundwater recharge and discharge. Because of the size and complexity of the model area, a considerable quantity of data was collected and analyzed in support of the modeling efforts. The data analysis task was consequently broken into eight subtasks, and descriptions of each subtask's activities are contained in one of the eight volumes that comprise the Phase I Data Analysis Documentation.

1996-10-01

439

Severe paraquat poisoning: clinical and radiological findings in a survivor  

International Nuclear Information System (INIS)

Paraquat is a nonselective contact herbicide of great toxicological importance, being associated with high mortality rates, mainly due to respiratory failure. We report the case of a 22-year-old male admitted to the emergency room with a sore throat, dysphagia, hemoptysis, and retrosternal pain after the ingestion of 50 mL of a paraquat solution, four days prior to admission. Chest CT scans revealed pulmonary opacities, pneumomediastinum, pneumothorax, and subcutaneous emphysema. The patient was submitted to two cycles of immunosuppressive therapy with cyclophosphamide, methylprednisolone, and dexamethasone. The pulmonary gas exchange parameters gradually improved, and the patient was discharged four weeks later. The clinical and tomographic follow-up evaluations performed at four months after discharge showed that there had been further clinical improvement. We also present a brief review of the literature, as well as a discussion of the ...

440

Severe paraquat poisoning: clinical and radiological findings in a survivor  

Energy Technology Data Exchange (ETDEWEB)

Paraquat is a nonselective contact herbicide of great toxicological importance, being associated with high mortality rates, mainly due to respiratory failure. We report the case of a 22-year-old male admitted to the emergency room with a sore throat, dysphagia, hemoptysis, and retrosternal pain after the ingestion of 50 mL of a paraquat solution, four days prior to admission. Chest CT scans revealed pulmonary opacities, pneumomediastinum, pneumothorax, and subcutaneous emphysema. The patient was submitted to two cycles of immunosuppressive therapy with cyclophosphamide, methylprednisolone, and dexamethasone. The pulmonary gas exchange parameters gradually improved, and the patient was discharged four weeks later. The clinical and tomographic follow-up evaluations performed at four months after discharge showed that there had been further clinical improvement. We also present a brief review of the literature, as well as a discussion of the ...

2010-07-01

441

Reliability analysis of the downstream face of a rockfill dam. Introductory work  

Energy Technology Data Exchange (ETDEWEB)

Reliability analysis is now being used to a large extent for several civil engineering structures. Such analysis has not been used for rockfill dams, the most common dams in Norway. Following work on reliability analysis for breakwaters, reliability analysis was then used to investigate the ability of the stone material on the upstream face of a rockfill dam to withstand wind generated waves. An attempt is made to follow up this work by including discharge overtopping on a rockfill dam in a reliability analysis. This report primarily goes through previous work on the required weight of protective stones on the downstream face of the dam for specified discharges over the dam and also deals with the probability formulation of extreme floods. A failure function with partial coefficients is formulated. But for reasons of economy the calibration of the partial coefficients remains for a next phase of the project. 14 refs., 17 figs.

1995-02-01

442

Pentobarbital anesthesia alters neural responses in the precedence effect  

British Library Electronic Table of Contents (United Kingdom)

The precedence effect (PE) is thought to be beneficial for proper localization and perception of sounds. The majority of recent physiological studies focus on the neural discharges correlated with PE in the inferior colliculus (IC). Pentobarbital anesthesia is widely used in physiological studies. However, little is known of the effect of pentobarbital on the discharge of neurons in PE. Neuronal responses in the IC from 23 male SD rats were recorded by standard extracellular recording techniques following presentation of 4ms white noise bursts, presented from either or both of two loud speakers, at different interstimulus delays (ISDs). The neural responses were recorded for off-line analysis before or after intraperitoneal administration of pentobarbital at a loading or maintenance dose. ...

2011-01-01

443

Optimized zinc electrode for the rechargeable zinc-air battery  

Energy Technology Data Exchange (ETDEWEB)

For the development of a long-lived, electrically rechargeable zinc-air battery the structure and wettability of pasted zinc electrodes were optimized. Pasted zinc electrodes containing 1 to 10% cellulose, but having almost the same nominal capacities, were prepared and tested in zinc/oxygen cells. The effect of discharge rate on cell voltage and delivered capacity, as well as the maximum power, were measured. Furthermore, cell charge-discharge behaviour and cycle life were examined. After different times of operation, the porosity and the pore size distribution of the pasted zinc electrodes were measured by means of mercury porosimetry. The life cycle and peak power drain capability of the Zn/oxygen battery could be substantially improved by the addition of 10 wt% cellulose to the pasted zinc electrode. (author)

1998-09-01

444

On plasma nitriding of steels  

Energy Technology Data Exchange (ETDEWEB)

With the aim of optimizing the nitriding process, experimental studies of the plasma nitriding of four selected steels were carried out, using a d.c. glow discharge. The process parameters were varied systematically. By means of transmission and scanning electron microscopy and X-ray diffraction, the microstructures, including the thicknesses of the compound zones and the diffusion zones of the nitrided steels, were obtained. Using cross-sectional samples and a micro-Vickers indenter, hardness depth profiles were also obtained. From the time and temperature dependences of the hardness profiles, effective diffusion constants and corresponding activation enthalpies were obtained. Furthermore, in an attempt to shed some light on the atomistic nitriding mechanisms, the glow discharges were studied by measuring energy spectra of the energetic ions hitting the cathode (the steel test specimens). It was shown that an increase of the mean energy of the ...

2000-02-01

445

Nanocrystalline MnO thin film anode for lithium ion batteries with low overpotential  

Energy Technology Data Exchange (ETDEWEB)

Nanocrystalline MnO thin film has been prepared by a pulsed laser deposition (PLD) method. The reversible lithium storage capacity of the MnO thin film electrodes at 0.125C is over 472 mAh g{sup -1} (3484 mAh cm{sup -3}) and can be retained more than 90% after 25 cycles. At a rate of 6C, 55% value of the capacity at 0.125C rate can be obtained for both charge and discharge. As-prepared MnO thin film electrodes show the lowest values of overpotential for both charge and discharge among transition metal oxides. All these performances make MnO a promising high capacity anode material for Li-ion batteries. (author)

2009-04-15

446

Mechanism of the electric field effect on the intensity of visible continuum emission from the positive column of gas discharge in a cesium vapor-xenon mixture  

British Library Electronic Table of Contents (United Kingdom)

We have studied the nature of continuum emitted in the visible spectral range from a noncontracted positive column of discharge in a cesium vapor-xenon mixture at a pressure of 45 Torr and at a degree of ionization below 3 ? 10?6. The main contribution to the continuous emission under such conditions is due to electron-xenon atom bremsstrahlung. The intensity of emission has been experimentally and theoretically studied as a function of the electric field strength and electron density in the positive column. It is established that an increase in the visible emission intensity with the electric field strength is related to an increase in the number of hot electrons in plasma.

2007-01-01

447

Infant well-being following neonatal cardiac surgery  

British Library Electronic Table of Contents (United Kingdom)

Aims and objectives.- To investigate infant well-being as measured by feeding and sleeping and parental support following discharge from the NICU in infants following major cardiac surgery. Background.- Infant feeding and sleeping have been identified as two of the most important concerns reported by parents. These concerns have been reported anecdotally for infants who have undergone cardiac surgery in the neonatal period. Design.- A prospective study using questionnaires and phone interviews followed a cohort of parents of neonates who underwent surgery in the neonatal period for congenital heart disease. Methods.- The study was conducted using validated questionnaires and phone interviews with a semi-structured questionnaire. The questionnaires were administered prior to discharge from ...

2011-01-01

448

Inactivation of Microcystis aeruginosa with Contact Glow Discharge Electrolysis  

British Library Electronic Table of Contents (United Kingdom)

This work investigated the inactivation of Microcystis aeruginosa (MA) with contact glow discharge electrolysis (CGDE). The influences of applied voltage, current and treatment time on the inactivation rate were critically examined. Based on the above results, the optimal conditions were chosen to sufficiently utilize chemically active species and enhance the inactivation of MA. Under the optimal conditions (voltage: 530?V; current: 30?mA; treatment time: 20?min), the inactivation rate of algae was more than 90% within 5?days incubation after inoculating. At the same time, the concentrations of Chlorophyll-a and dehydrogenase decreased, which demonstrated that 20?min CGDE treatment could effectively inhibit the growth of MA and caused deterioration of cell integrity. The present work would...

2011-01-01

449

High capacity Si/DC/MWCNTs nanocomposite anode materials for lithium ion batteries  

International Nuclear Information System (INIS)

Nanocomposites comprising nanocrystal silicon (Si), disordered carbon (DC), and multi-walled carbon nanotubes (MWCNTs) - denoted as Si/DC/MWCNTs - have been prepared by pyrolyzing the phenol-formaldehyde resin (PFR) mixed with Si and MWCNTs. This nanocomposite anode material showed a discharge capacity of 1216 mAh/g in the first cycle, and a charge capacity of 711 mAh/g after 20 charge-discharge, much higher than that of Si/DC composite. It can be observed that Si particles wrapped in MWCNTs were homogeneously embedded into the matrix of the DC. The improved electrochemical performance is hypothesized to be mainly attributed to the morphology stability of the composite due to the excellent resiliency and distinct electric conductivity of the MWCNTs.

2010-03-18

450

Full size zinc-air battery  

Energy Technology Data Exchange (ETDEWEB)

The Electric Fuel zinc-air battery yielded energy densities from 6.8 to 10.2 times higher than those of the lead-acid batteries. The higher the power and the more difficult the driving cycle, the higher this ratio of energy densities grew. Not only was the Electric Fuel battery capable of extended high-power discharge, the impact of such discharge conditions on energy and driving range was show to be quite small, and was much smaller than the comparable impact on lead-acid traction batteries. At the time of writing this paper, tests are scheduled to continue with the 110-kWh battery in the Mercedes van, and preliminary plans have been made for testing of additional batteries on other vehicle types.

1993-11-01

451

Explosives sensor  

Energy Technology Data Exchange (ETDEWEB)

A compact and supersensitive device that can rapidly detect minute trace vapors from concealed explosives has been developed by scientists at Oak Ridge National Laboratory (ORNL). The new explosives sensor can detect and chemically identify organic nitrogen-oxygen compounds which are the building blocks of explosives such as TNT, plastiques, and nitroglycerine. The device could be used to scan persons entering airport terminals, nuclear power plants, defense installations, or other sensitive locations, providing greater security against potential terrorism. This device works on a glow discharge principle, and is more specifically called an ''Atmospheric Sampling Glow Discharge Ionization'' (ASGDI) source. The new detector is a highly automated, miniaturized version of research mass spectrometers widely used to trace constituents of chemical mixtures. Detail of this device's construction and ...

1987-01-01

452

Electrochemical hydrogen storage behaviors of ultrafine Co-P particles prepared by direct ball-milling method  

Energy Technology Data Exchange (ETDEWEB)

Ultrafine particles of Co-P were synthesized by direct ball milling of Co and P powders and also investigated as a reversible hydrogen storage electrode material. The electrochemical results demonstrated that the reversible charge-discharge capacity of the Co-P electrode can reach more than 300mAh/g. In addition, the cycling ability and high rate capability of the Co-P electrode are excellent with only 5% capacity decay after 100 cycles at a high rate of 300mA/g. The temperature-programmed desorption measurements (TPD) of the Co-P electrode revealed that the charge and discharge reactions of the Co-P electrode proceeds predominantly through electrochemical hydrogen storage mechanism and the electrooxidation of cobalt contributes only a negligible part to the reversible electrochemical capacity. (author)

2006-05-25

453

Electrically rechargeable zinc/air battery: a high specific energy system  

Energy Technology Data Exchange (ETDEWEB)

This contribution describes our research and development efforts towards the demonstration of a light-weight, low-cost 12 V/20 Ah electrically rechargeable Zn/air battery. We successfully developed electrodes having active areas of up to 200 cm{sup 2}. Deep discharge cycles at different currents as well as current-voltage curves are reported for a 10 cell Zn/air battery (serial connection) with a rated capacity of 20 Ah. Based on the discharge cycle at a power of 19 W, and the weight of the battery, a specific energy of more than 90 Wh/kg could be evaluated for the whole system. (author) 4 figs., 1 tab., 5 refs.

1999-08-01

454

Effects of sawtooth crashes on beam ions and fusion product tritons in JET  

Energy Technology Data Exchange (ETDEWEB)

The effect of a sawtooth crash on the radial distribution of the slowing down fusion product tritons and on beams ions, is examined with measurements of the 2.5 MeV and 14 MeV neutron emission line-integrals before and after sawtooth crashes. In deuterium discharges, the 14 MeV neutron production was wholly attributable to burnup of the 1 MeV fusion product tritons from d-d fusion. The local emissivity of 14 MeV neutrons, and hence of the profile of thermalizing tritons, is shown to be only weakly affected by crashes in the discharges studied. This is in contradiction with the apparent behaviour of injected beam ions as deduced from a study of the considerable changes in local emissivity of the 2.5 MeV neutrons. Nevertheless, the behaviour of the fusion product tritons is consistent with the scaling of the beam injected deuterium. 1 ref., 6 figs.

1994-07-01

455

Dependence of nitriding degree of Ti surface by non-LTE nitrogen plasma on various plasma parameters  

International Nuclear Information System (INIS)

Experiments of plasma nitriding of titanium are carried out by two plasma sources. One is a microwave discharge plasma source under several Torr, and the other is a nitrogen arc jet generated under atmospheric pressure followed by rapid expansion into a gas wind tunnel. The relationship between the surface density of nitrogen atoms in the #alpha#-Ti and various plasma parameters is systematically studied. For the microwave nitrogen plasma, it is found that the effect of the vibration temperature is the most essential for the surface nitriding, whereas the effect of electron temperature, density and rotation temperature is less remarkable. It is also found that the higher vibration temperature of the microwave discharge nitrogen plasma makes the target temperature higher, and consequently, the surface density of atomic nitrogen remarkably increased. However, the effect of target temperature is less remarkable for the arc jet nitrogen plasma.

2004-06-01

456

DBD Surface Modification of Polymers in Relation to the Spatial Distribution of Reactive Oxygen Species  

British Library Electronic Table of Contents (United Kingdom)

The homogeneity of a helium dielectric barrier discharge, working at atmospheric pressure and containing oxygen as contaminant, is assessed by mapping the spatial distribution of oxygen metastable atoms in relation to the uniformity of surface properties. Tunable diode laser absorption spectroscopy is used to monitor the time evolution of the absorption coefficient corresponding to the oxygen metastable atoms on the 35S2 level, as a function of the laser absorbing path, whereas bi-dimensional Abel transform is used to obtain local information on the space distribution of the metastable atoms in the discharge. The radial distribution of the surface properties is investigated using atomic force microscopy, contact angle measurement and X-ray photoelectron spectroscopy. The results show that ...

2011-01-01

457

Continuous-wave cavity ringdown spectroscopy of the Formula Not Shown Meinel system (2,1) band  

British Library Electronic Table of Contents (United Kingdom)

The Formula Not Shown system of Formula Not Shown was first observed in auroral emissions by Meinel in 1950. Although the Formula Not Shown band system has been reinvestigated since this first spectral study, no laboratory spectrum of the (2,1) vibronic band has been obtained. We have recently built a continuous-wave cavity ringdown spectrometer, and as a first test of this spectrometer we observed the (2,1) band of Formula Not Shown in a positive column discharge cell. Many lines of the first positive band system of Formula Not Shown were also identified during the process of assigning this spectrum. The relative intensities of the Formula Not Shown and Formula Not Shown bands were found to change with discharge cell pressure, and so each spectral region was observed at two pressures to a...

2008-01-01

458

Assimilating remote sensing and in situ observations into a coastal model of northern South China Sea using ensemble Kalman filter  

British Library Electronic Table of Contents (United Kingdom)

Major forecast errors on the background error covariance from initial conditions, atmospheric forcing, model open boundary conditions, and the river discharges are examined in a coastal model of northern South China Sea. The analysis of background error covariance matrix produced by model ensemble shows that the perturbations of the initial conditions and atmospheric forcing play major roles in producing and maintaining the amplitude of ensemble spread except for the sea surface height (SSH) field. The perturbation of model open boundary conditions can influence ensemble spread of all variables and covariance between temperature and velocity or between temperature and SSH. The perturbation of river discharge mainly affects the covariance of salinity in river estuary. A data assimilation ex...

2011-01-01

459

Apparatus for producing controlled positive or negative corona discharge for semiconductor materials processing  

Energy Technology Data Exchange (ETDEWEB)

An apparatus capable of producing current or voltage controlled positive and negative ion beams in 1-atm oxidizing and nonoxidizing ambients between 25/sup 0/ and 950 /sup 0/C is presented. The apparatus utilizes a point-to-plane corona discharge in the gas phase. Room-temperature experiments revealed that the small differences in ion beam shape between the two polarities is primarily due to the difference in applied voltage required to produce the same current for the two polarities. Due to increased ion mobility and decreased threshold voltage at higher temperatures, a slight broadening of the ion beam current-density profiles for both positive and negative ions is predicted.

1984-09-01

460

Ambulatory open Bankart repair under a single general anesthesia: A prospective study of the immediate outcome  

British Library Electronic Table of Contents (United Kingdom)

The interscalenic block technique is widely used for ambulatory shoulder surgery despite a substantial number of failures and adverse effects. We prospectively evaluated satisfaction in 40 consecutive patients who underwent open Bankart repair under a single general anesthesic performed in an ambulatory care unit. The mean age of the patients was 23 years. There were 29 men and 11 women. Patients were evaluated postoperatively with a visual analog scale of pain (in the recovery room, at the time of discharge, and the day after and 1 week after surgery) via a home assessment questionnaire that included the following: effectiveness of oral pain medication, ability to perform activities of daily life, and overall satisfaction. One patient failed to be discharged because of a feeling of faintn...

2006-01-01

461

A calculation method of running range of electric vehicle with battery hybrid system  

Energy Technology Data Exchange (ETDEWEB)

Much attention is being paid to electric vehicles from environmental standpoints. One disadvantage of the electric vehicle is that its operative range is short. A means to overcome this difficulty is to use a hybrid battery which consist of a energy battery and a power battery. A method to make it possible to calculate the discharge characteristics of the battery hybrid system taking into account the charging behavior from the energy battery to the power battery is presented. In the proposed method, first the output voltage and the output current of an equivalent battery, which is required for realizing the given operating pattern are calculated. Next, the conduction ratio of the main chopper and the equivalent discharge of electric charge of each battery are calculated. These calculated data are used to calculate the operating range.

1980-05-01

462

3D investigations of plasma erosion craters using FIB/SEM dual-beam techniques  

Energy Technology Data Exchange (ETDEWEB)

Plasma erosion craters caused by electrical discharges on the surface of materials are important features of the erosion processes resulting in the degradation of electrodes. In the present work, electrical discharges were produced on a bi-metallic Ni/Cu multilayered surface. By means of dual beam techniques, coupling a focused ion beam (FIB) and a scanning electron microscope (SEM), not only the surface but also the sub-surface structure of the craters were investigated. Using the combination of SEM, FIB and STEM-EDX, a complete three-dimensional investigation of the craters were carried out. The analysis of the microstructure modifications as a function of depth enabled to determine the field of interaction between the plasma and the material. (orig.)

2006-09-15

463

Regulatory quality assurance requirements for the operation of nuclear R and D facilities in Korea  

International Nuclear Information System (INIS)

Full text: Korea Atomic Energy Research Institute (KAERI) has many R and D facilities in operation. including HANARO research reactor, radioactive waste treatment facility (RWTF), post-irradiation examination facility (PIEF) and irradiated material test facility (IMEF). Recently. nation-wide interest is focused on the safety and security of major industrial facilities. Safe operation of nuclear facilities is imperative because of the consequence of public disaster by radiological release/contamination, in case of an accident. Recently, Ministry of Science and Technology (MOST) of the Korean government announced amendments of Atomic Energy laws to enforce requirements of the physical protection and radiological emergency. All provisions on nuclear safety regulation and radiation protection are entrusted to the Atomic Energy Act(AEA). The Act is enacted as the ...

2006-10-15

464

The seeded growth of calcium sulfate dihydrate crystals in NaCl solutions up to 6 m and 90 C  

Energy Technology Data Exchange (ETDEWEB)

The kinetics of calcium sulfate crystal growth is of importance in various fields, such as geochemistry, desalination technology, petroleum industry, and water and wastewater treatment. The seeded crystal growth rate of calcium sulfate dihydrate was measured as a function of supersaturation in NaCl electrolyte solutions from 0 to 6 m at temperatures of 25, 50, 70, and 90 C. The growth followed a second-order parabolic rate law with activation energies greater than 53 kJ/mol which suggested the surface reaction as the rate-limiting step. It was observed that the rate constant and the activation energy are solution composition dependent. The rate constant increases with NaCl concentration up to 3 molal and then begins to fall slightly. The activation energy dropped from 61 kJ/mol in the pure Ca-SO[sub 4]H[sub 2]O system to 53 kJ/mol in 3.0 m NaCl solutions. The electrolyte effect was similar to the crystal solubility behavior in aqueous electrolyte solutions ...

1994-03-15

465

Test of electron beam technology on Savannah River Laboratory low-activity aqueous waste for destruction of benzene, benzene derivatives, and bacteria  

Energy Technology Data Exchange (ETDEWEB)

High energy radiation was studied as a means for destroying hazardous organic chemical wastes. Tests were conducted at bench scale with a {sup 60}Co source, and at full scale (387 l/min) with a 1.5 MV electron beam source. Bench scale tests for both benzene and phenol included 32 permutations of water quality factors. For some water qualities, as much as 99.99% of benzene or 90% of phenol were removed by 775 krads of {sup 60}Co irradiation. Full scale testing for destruction of benzene in a simulated waste-water mix showed loss of 97% of benzene following an 800 krad dose and 88% following a 500 krad dose. At these loss rates, approximately 5 Mrad of electron beam irradiation is required to reduce concentrations from 100 g/l to drinking water quality (5 {mu}g/l). Since many waste streams are also inhabited by bacterial populations which may affect filtering operations, the effect of irradiation on those populations was also studied. {sup 60}Co and electron beam ...

1993-08-01

466

Study on biosorption kinetics and thermodynamics of uranium by Citrobacter freudii  

Energy Technology Data Exchange (ETDEWEB)

Biosorption has been developed as an effective and economic method to treat wastewater containing low concentrations of metal pollutants. In this study, a bacterium, Citrobacter freudii, was used as a biosorbent to adsorb uranium ions. The thermodynamics and kinetics of this adsorption, as well as its mechanism, were investigated. The results indicated that the biosorption rate could be better described by a pseudo 2nd-order model than a pseudo 1st-order model. The adsorption of U (VI) proceeded very rapidly in the first 30 min and subsequently slowed down continuously for a long period. The biosorption isotherm of uranium by C. freudii could be described well by the Langmuir or Freundlich isotherm, and the latter was better. The thermodynamics parameters, {delta}H{sup o}, {delta}G{sup o}, and {delta}S{sup o} were calculated according to the results of the experiment, which showed this biosorption as being endothermic and spontaneous. The authors investigated the ...

2008-01-15

467

Soil water retention at varying matric potentials following repeated wetting with modestly saline-sodic water and subsequent air drying  

Energy Technology Data Exchange (ETDEWEB)

Coal bed natural gas (CBNG) development in the Powder River (PR) Basin produces modestly saline, highly sodic wastewater. This study assessed impacts of wetting four textural groups (0-11%, 12-22%, 23 -33%, and > 33% clay (g clay/100 g soil) x 100%))with simulated PR or CBNG water on water retention. Soils received the following treatments with each water quality: a single wetting event, five wetting and drying events, or five wetting and drying events followed by leaching with salt-free water. Treated samples were then resaturated with the final treatment water and equilibrated to -10, -33, -100, -500, or -1,500 kPa. At all potentials, soil water retention increased significantly with increasing clay content. Drought-prone soils lost water-holding capacity between saturation and field capacity with repeated wetting and drying, whereas finer textured soils withstood this treatment better and had increased water-retention capacity at lower matric potentials.

2007-07-01

468

Selecting soil amendment materials for removal of phosphorus  

Energy Technology Data Exchange (ETDEWEB)

Phosphorus sorption capacities of several different materials including Merribrook soil (a loamy sand) and some industrial solid wastes (red mud neutralized with gypsum, fly ash, bottom ash and black oxide) were determined in sorption isotherms by Langmuir and Freundlich equations. The materials were characterized by bulk density, particle density, total porosity and particle size distributions. Red mud gypsum possessed the best sorption capacity based on the Langmuir maxima. Alkaline fly ash and Merribrook soil had lower sorption maxima compared to the red mud gypsum. Bottom ash and acidic fly ash had very low sorption capacity at low concentrations. Merribrook soil had the highest hydraulic conductivity. The results suggested that alkaline fly ash may be a promising amendment for coarse sand bed to enhance phosphorus removal. Merribrook soil appears to be suitable for on-site wastewater treatment.

1994-12-31

469

Radioactive contamination of fish, shellfish, and waterfowl exposed to Hanford effluents: Annual summaries, 1945--1972. Hanford Environmental Dose Reconstruction Project  

Energy Technology Data Exchange (ETDEWEB)

The objective of the Hanford Environmental Dose Reconstruction Project (HEDR) is to estimate the potential radiation doses received by people living within the sphere of influence of the Hanford Site. A potential critical pathway for human radiation exposure is through the consumption of waterfowl that frequent onsite waste-water ponds or through eating of fish, shellfish, and waterfowl that reside in/on the Columbia River and its tributaries downstream of the reactors. This document summarizes information on fish, shellfish, and waterfowl radiation contamination for samples collected by Hanford monitoring personnel and offsite agencies for the period 1945 to 1972. Specific information includes the types of organisms sampled, the kinds of tissues and organs analyzed, the sampling locations, and the radionuclides reported. Some tissue concentrations are also included. We anticipate that these yearly summaries will be helpful to individuals and organizations ...

1992-07-01

470

Radioactive contamination of fish, shellfish, and waterfowl exposed to Hanford effluents: Annual summaries, 1945--1972  

Energy Technology Data Exchange (ETDEWEB)

The objective of the Hanford Environmental Dose Reconstruction Project (HEDR) is to estimate the potential radiation doses received by people living within the sphere of influence of the Hanford Site. A potential critical pathway for human radiation exposure is through the consumption of waterfowl that frequent onsite waste-water ponds or through eating of fish, shellfish, and waterfowl that reside in/on the Columbia River and its tributaries downstream of the reactors. This document summarizes information on fish, shellfish, and waterfowl radiation contamination for samples collected by Hanford monitoring personnel and offsite agencies for the period 1945 to 1972. Specific information includes the types of organisms sampled, the kinds of tissues and organs analyzed, the sampling locations, and the radionuclides reported. Some tissue concentrations are also included. We anticipate that these yearly summaries will be helpful to individuals and organizations ...

1992-07-01

471

Radioactive contamination of fish, shellfish, and waterfowl exposed to Hanford effluents: Annual summaries, 1945--1972  

International Nuclear Information System (INIS)

The objective of the Hanford Environmental Dose Reconstruction Project (HEDR) is to estimate the potential radiation doses received by people living within the sphere of influence of the Hanford Site. A potential critical pathway for human radiation exposure is through the consumption of waterfowl that frequent onsite waste-water ponds or through eating of fish, shellfish, and waterfowl that reside in/on the Columbia River and its tributaries downstream of the reactors. This document summarizes information on fish, shellfish, and waterfowl radiation contamination for samples collected by Hanford monitoring personnel and offsite agencies for the period 1945 to 1972. Specific information includes the types of organisms sampled, the kinds of tissues and organs analyzed, the sampling locations, and the radionuclides reported. Some tissue concentrations are also included. We anticipate that these yearly summaries will be helpful to individuals and organizations ...

472

Potential biogas scrubbing using a high rate pond  

Energy Technology Data Exchange (ETDEWEB)

The potential to scrub biogas in a high rate pond (HRP) was evaluated using apparatus designed to maximize gas-liquid contact. Experiments compared the removal of carbon dioxide from synthetic biogas by an 'in-pond angled gutter' to that by a simulated 'counter-current pit'. Results showed that the counter current pit has potential for use in biogas scrubbing, with synthetic biogas carbon dioxide composition consistently reduced from 40% to<5%. The in-pond angled gutter was less effective due to bubble coalescence which reduced the total bubble surface surface area available for gas transfer. Measurement of oxygen levels in the scrubbed biogas showed that despite supersaturation of oxygen in the HRP water, there was little transfer to the biogas, so that explosive methane/oxygen mixtures would not be formed. Theoretical calculations indicated that the amount of biogas likely to be formed during anaerobic treatment of municipal ...

2005-07-01

473

Measuring instrument for radiometric monitoring of solids and heavy metals in water  

International Nuclear Information System (INIS)

A combination of measuring instruments, consisting of a Beta-Sedimeter and a radionuclide X-ray fluorescence instrument, is described. With the Beta-Sedimeter the C-14-radiation is measured. Through direct irradiation with photons of a Pu238-source in an ancillary irradiation chamber and energy dispersing measurement of the K- and L-radiation resp. of the excited heavy metals with the aid of a Si(Li)-semiconductor detector and a 4-channel analyzer the heavy metal concentrations of the heavy metals Zn, Cr, Ni and Pb are determined. For the determination of cadmium the indirect excitation with Am-241 and Dy-targets is described. The system produces records and operates fully automatically in a step-by-step mode with a testing cycle of 45 minutes. In connection with the process monitoring of the wastewater from a zinc plating plant during a period of 8 months the concentration of the solid material and of the metals Cr and Zn, which were considered to be ...

1979-01-01

474

Management of industrial solid wastes in Alexandria, Egypt  

Science.gov (United States)

This paper presents a summary of the first phase of the EPA project, which encompasses surveys of residues from industrial sources in Alexandria. Studies to date indicate that wastes from various industries can be recovered economically. Wastes such as tin cans, glass, wastepaper, and food residues from processing of fruits, starch, and beer are examples of reusable industrial wastes in Egypt. The results of experimental studies for reuse of residues from oil refining, starch and yeast processing, and steel pickling are presented. Spent clay from edible oil refining is currently discarded, causing both handling and disposal problems. This clay contains as much as 40% oil; 90% can be recovered by extraction. The recovered oil can be successfully used in soap production, and the spent clay can be reused in oil bleaching. Other examples include starch and yeast wastes, which can be used for animal feed, and spent pickling liquor, which can be used as a coagulant aid for treating paper ...

1983-03-01

475

Isolation and Identification of Achromobacter sp. DN-06 and Evaluation of Its Pyridine Degradation Kinetics  

British Library Electronic Table of Contents (United Kingdom)

We report the isolation of a new bacterium species (named as DN-06) that degrades pyridine, a model compound containing both carbon and nitrogen, from the aerobic activated sludge in a coking wastewater treatment plant. DN-06 was identified as Achromobacter sp. using 16S rDNA sequence analysis. In batch culture, more than 95% of pyridine (500?mg/L) was degraded within 18?h by DN-06 grown at 35?C and pH?8 with agitation at 170?rpm. Degradation experiments of pyridine at different initial concentrations (50?4,300?mg/L) revealed that pyridine was an inhibitory substrate, and that neither yield coefficient Y nor endogenous decay coefficient K d was a constant. The values of Y and K d were 0.55?0.74 and 0.0032?0.0057?h?1, respectively. Five kinetic models (Haldane, Yano, Aiba, Webb, and Monod) ...

2011-01-01

476

International symposium: concepts for the treatment of wastewater in the rural areas of Europe. Proceedings; Internationales Symposium: Konzepte zur Abwasserbehandlung im laendlichen Raum Europas. Tagungsband  

Energy Technology Data Exchange (ETDEWEB)

In the first part of the symposium, experts reviewed the state of the art of decentralized waste water treatment in Europe. In the second part, exemplary solutions in Poland and the Czech Republic were presented. The final part was dedicated to future concepts and strategies. [German] Im Herbst letzten Jahres hat die Kommunale Umwelt-AktioN U.A.N. in einer Abfolge von drei Abwasserfachsymposien Expertenrunden zum Austausch ueber den aktuellen Stand des Wissens zum Thema dezentrale Abwasserbehandlung veranstaltet. Mit dem Internationalen Symposium 'Konzepte zur Abwasserbehandlung im laendlichen Raum Europas' in Celle hat das Projekt der U.A.N. seinen Abschluss gefunden. Der Konzeption des Projektes entsprechend haben im 1. Teil des Symposiums Experten ueber den Stand der Entwicklung auf dem Sektor der dezentralen Abwasserbehandlung in Deutschland berichtet. Im 2. Teil unserer Fachtagung wurden europaeische Beispiele fuer dezentrale Loesungen aus Polen und Tschechien ...

2000-07-01

477

Elimination of organics chemicals in aqueous solutions by gamma radiation processing  

International Nuclear Information System (INIS)

The objective this work was to evaluate the gamma radiation processing for elimination of organic contaminants on industrial wastewater. Standard samples with 17 hydrocarbons (acetophenone, anisole, benzene, chlorobenzene, cyclohexanone, N, N-dimethylaniline, phenol, naphtalene, 1-chloronaphtalene, n-octadecane, p-nitrotoluene, toluene, tetrachloroethane, tetramethylbenzene, n-undecane, m-xylene and o-xylene) was preparated in hexane with total concentration of 1 #mu# g/ #mu# l which was analyzed by gas chromatography. Other sample with the same concentration of these hydrocarbons in acetone was used to contaminate water samples, which were irradiated with gamma radiation from Co-60 between doses 5.0 to 20.0 KGy and dose rate of 1.162 KGy/h. The activity of source was 1470 Ci. Percents destruction of hydrocarbons were: 79.76 % to 5.0 KGy, 85.97 % to 7.5 KGy, 86.24 % to 10.0 KGy, 86.72 % to 12.5 KGy, 88.92 % to 15.0 KGy, 91.74 % to 17.5 KGy and 92.38 % to 20.0 KGy. ...

1992-08-16

478

ELECTROLYTIC MEMBRANE DIALYSIS FOR TREATING WASTEWATER STREAMS  

Energy Technology Data Exchange (ETDEWEB)

This project will determine whether electrolytic dialysis has promise in the separation of charged particles in an aqueous solution. The ability to selectively move ions from one aqueous solution to another through a semipermeable membrane will be studied as a function of emf, amperage, and particle electrical charge. The ions selected for the study are Cl{sup -} and SO{sub 4}{sup 2-}. These ions are of particular interest because of their electrical conduction properties in aqueous solution resulting with their association with the corrosive action of metals. The studies will be performed with commercial membranes on solutions prepared in the laboratory from reagent salts. pH adjustments will be made with dilute reagent acid and base. Specific objectives of the project include testing a selected membrane currently available for electrolytic dialysis, membrane resistance to extreme pH conditions, the effectiveness of separating a mixture of two ions selected on the basis of size, the ...

2000-04-01

479

Continuous fermentative hydrogen production in different process conditions  

Energy Technology Data Exchange (ETDEWEB)

This paper reported on a study in which hydrogen was produced by fermentation of biomass. A continuous process using a non-sterile substrate with a readily available mixed microflora was used on heat treated digested sewage sludge from a wastewater treatment plant. Hydrogen was produced from waste sugar at a pH of 5.2 and a temperature of 37 degrees C. An experimental setup of three 5.5 L working volume continuously stirred tank reactors (CSTR) in different stirring speeds were constructed and operated at 7 different hydraulic retention times (HRTs) and different organic loading rates (OLR). Dissolved organic carbon was examined. The results showed that the stirring speed of 135 rpm had a beneficial effect on hydrogen fermentation. The best performance was obtained in 135 rpm and 8 h of HRT. The amount of gas varied with different OLRs, but could be stabilized on a high level. Methane was not detected when the HRT was less than 16 h. The study identified the ...

2010-07-01

480

Coir pith of the green coconut in the decontamination of radioactive aqueous effluent  

International Nuclear Information System (INIS)

Industrial segments as plant of mining, hospitals and university generate considerable volumes of radioactive wastewater containing uranium. The increasing development of the use of the nuclear energy to lead away to an expansion of the sectors of the nuclear fuel cycle, but it leads to security problems and it appears the necessity of control of the removing of uranium and radioactive effluent treatments. Researches evaluate if the technique of the biosorption would promote an alternative process with attractive characteristics of cost-benefit. The residual biomass from agricultural activities has been studied and used as adsorbent of metals and organic composts by low cost, abundance and for being biodegradable. In this work, it is presented the efficiency of the coir pith for the adsorption of ions UO_2"2"+. The coir pith is a by-product of the harvest of the coconut, a renewable natural source. The study was accomplished using the batch techniques. The ...

481

A simple model for strontium breakthrough on zeolite columns  

Science.gov (United States)

The Process Waste Treatment Plant (PWTP) at the Oak Ridge National Laboratory is designed to remove radioactive contaminants, principally {sup 90}Sr, from process wastewater. Planned upgrades to the PWTP will use chabazite zeolite columns. Pilot-scale studies have shown that mass transfer zone lengths increase from 10 to about 30 cm as the superficial velocity increases from 5.5 to 22 cm/min. Calculations with a multicomponent equilibrium model showed that the distribution coefficient for strontium remains essentially constant over the process conditions, suggesting that a simple kinetic model (the Rosen long-bed solution) should adequately represent breakthrough behavior. Using a distribution coefficient of 4.87 L/g predicted by the equilibrium model, good agreement was found between experimental breakthrough curves and those calculated with the Rosen solution. This model allows prediction of bed depths and cycle times necessary to achieve the required ...

1995-04-01

482

Why the negative corona current in air decreases?  

International Nuclear Information System (INIS)

The time dependence of negative corona current I, called by Gagarin like 'relaxing of CV-characteristics', is a observed phenomena. The observed phenomena was explained by two theoretical models considering the ion-molecule and chemical reactions in the negative corona discharges in air, especially the ozone production. In the presented paper the discrepancies of above mentioned models, re-examination the earlier experimental data and presumptions used in models in a light the latest experimentally confirmed facts are discussed.

1996-08-01

483

Surface modification of LiNi{sub 1/2}Mn{sub 3/2}O{sub 4} thin-films by zirconium alkoxide/PMMA composites and their effects on electrochemical properties  

Energy Technology Data Exchange (ETDEWEB)

Three kinds of surface modifications were carried out on LiNi{sub 1/2}Mn{sub 3/2}O{sub 4} thin-films to improve the charge and discharge characteristics of LiNi{sub 1/2}Mn{sub 3/2}O{sub 4} positive electrodes. Among them, Zr(OBu){sub 4}/poly(methyl methacrylate) (PMMA)-treated LiNi{sub 1/2}Mn{sub 3/2}O{sub 4} thin-film electrodes showed charge and discharge efficiency of 80-84% in the first cycle, which was much higher than that for an untreated LiNi{sub 1/2}Mn{sub 3/2}O{sub 4} thin-film electrode (73%). The values of the charge and discharge efficiency were still higher than that for an untreated electrode after the 30th cycle. The charge and discharge curves gave two plateaus at around 4.72 and 4.76 V, which were very similar to those for the untreated electrode. Ac impedance spectroscopy revealed that the surface film resistance should not increase by Zr(OBu){sub 4}/PMMA treatment. XPS measurements ...

2008-10-15

484

Sources of X-rays in school; Zrodla promieniowania rentgenowskiego w szkole  

Energy Technology Data Exchange (ETDEWEB)

Exposure of teachers of physics to X-radiation emitted by instruments which are used for demonstrating rarefied gas discharges during physics lessons at secondary schools is discussed. The measurements performed provide an explicit evidence that an effective, annual exposure dose under the most unfavorable conditions does not exceed admissible levels according to Polish regulations pertaining to persons non-occupationally exposed to ionizing radiation. (author). 3 refs,1 fig.

1996-12-31

485

Slurry intake device  

Energy Technology Data Exchange (ETDEWEB)

A slurry intake device is proposed which contains an inlet sleeve, housing with grating installed with the discharge end in the zone of the slurry outlet, and hinged deflector. In order to conserve the clay mud, it is equipped with a tie rod and two-arm lever which is kinematically linked to the deflector and the grating. It is installed by hinges in relation to the housing and the latter is attached by hinges to the inlet sleeve. The deflector is arranged in the zone of slurry outlet. The device is distinguished by the fact that the deflector is equipped with a cantilever on which a fixable weight is attached.

1982-01-01

486

Self-simulating motion of an ionized gas expelled by a magnetic piston  

Energy Technology Data Exchange (ETDEWEB)

The paper deals with a model in which the motion of a gas in plasma accerators and high-curent discharges in the present of a skin effect is treated as expulsion by a 'magnetic piston' under the action of surface current flow. Specifically examined is the situation where the initial gas pressure is negligible in comparison with the magnetic pressure, and the motion of the gas may be treated as a self-simulating one. A system of hydrodynamic equations of the problem is derived and integrated by Adam's method. Results are plotted and discussed.

1980-01-01

487

Preparing for drilling operations in a harsh environment  

Energy Technology Data Exchange (ETDEWEB)

The Eiric Raude offshore drilling rig is a powerful machine that is suitable for drilling in harsh environments in ultra deep water. It has a total drilling depth of 8,200 to 10,000 metres and an operational displacement of 53,400 mt. The rig complies with the regulatory regimes of Norway, the United Kingdom and Canada. The Eiric Raude has drilled 5 deepwater wells offshore eastern Canada, 1 well offshore Cuba, 1 well west of Shetland, and 3 offshore Norway. The environmental criteria for extreme weather conditions consider wave, current and wind forces. The general operational guidelines were discussed along with key areas for prevention of environmental impact, including emissions from well testing, air emissions from diesel engines, cooling water, bunkering operations, discharges from drilling, accidental discharges, drain water, and domestic sewage. It was noted that the zero discharge philosophy is the basis for all ...

2005-07-01

488

Positive electrode for an alkaline primary air oxygen battery with thickened electrolyte. Positive Elektrode fuer ein alkalisches primaeres Luftsauerstoffelement mit eingedicktem Elektrolyten  

Energy Technology Data Exchange (ETDEWEB)

A cathode of improved discharge characteristics for a zinc-air battery is prepared from mixtures containing gamma-MnO/sub 2/ 33-67 wt%, C 12-40 wt% and KOH 20-28 wt%.

1981-06-19

489

Method for processing statistical information concerning sucker-rod pump unit operations  

Energy Technology Data Exchange (ETDEWEB)

The authors propose an integrated indicator of pump-rod couplings that allows both the couplings and the pump operations to be appraised according to the given formula. (Formula provided). The dynamic relationships of rod operations were determined with nomographs. These relationships involve such factors as: the type and size of the sucker-rod string; the pressure load at the equalizer head and its correlation to threshold pressure at pump discharge; pump diameter; the rod weight and construction; and integral reliability indicators.

1982-01-01

490

Guarantee outline of radiation hardening for satellite  

International Nuclear Information System (INIS)

The Guarantee Outline presents the technical demands of design and contents of assessment for radiation hardening in satellite engineering in China. It includes the basis of design in space environment of polar orbit, the contents of design for general radiation hardening, the requirements and assessments of the single-board computer, the requirements of design for circuits (including hardware and software), the choices and assessments for devices, and the primary stipulations for the requirements of design and assessments against the phenomenon of charge and discharge.

491

Glovebox  

Energy Technology Data Exchange (ETDEWEB)

On handling nitric solutions in the glove box nitrous gases are formed that are sucked off via a heated activated charcoal filter and a catalyst cartridge containing e.g. the FG 590 H catalist (Degussa). By the activated charcoal the nitrous gases are reduced to N/sub 2/ and CO gas; the catalyst will oxidize CO to CO/sub 2/. The CO/sub 2/ obtained is discharged through an exhaust air filter in the glove box.

1980-02-21

492

Fluidic pumps  

International Nuclear Information System (INIS)

A fluidic pump comprises a two-diode pump having a first displacement vessel, a third diode connected to receive output from the two-diode pump through a delivery line and discharge to an outlet, and a second displacement vessel connected to the delivery line. There is a feed tank at a greater height than the two-diode pump, and a drive unit for alternately pressurising and venting the first and second displacement vessels. The drive pressure required to operate the pump can be of the order of half that for a single stage 2-diode pump. (author).

1988-05-19

493

Economic analysis of proposed effluent limitations guidelines and standards for synthetic-based drilling fluids and other non-aqueous drilling fluids in the oil and gas extraction point source category  

Science.gov (United States)

The Economic Analysis (EA) report is written to address the impacts of this proposed Effluent Limitation Guidelines and Standards for Synthetic-Based and Other Non-Aqueous Drilling Fluids. Currently, effluent guidelines pertaining to the discharge of drilling fluids address two specific types of fluids: Oil-based drilling fluids (OBFs) that use diesel and mineral oil, which are prohibited from being discharged; and Water-based drilling Fluids (WBFs), which can be discharged subject to meeting certain discharge requirements, including a sheen test and an aqueous toxicity test, in certain limited offshore regions. Section Two presents sources of data, Section Three presents the industry profile, Section Four discusses the regulatory costs of options under consideration for the proposed rulemaking, and Section Five discusses the impacts of the proposed rule on firms, well drilling, and production, and also ...

1999-02-01

494

Cost effectiveness of Silent Discharge Plasma for point-of-use VOC emissions control in semiconductor fabrication  

Energy Technology Data Exchange (ETDEWEB)

Extensive research into the treatment and control of Volatile Organic Compounds (VOCs) from semiconductor industry manufacturing processes has identified the need for alternatives to existing combustion devices. Specifically, semiconductor manufacturing design is moving toward exploiting effective, small-scale, abatement control technologies for specific point-of-use (POU) waste streams associated with a particular component or manufacturing tool. The Silent Discharge Plasma (SDP) developed at Los Alamos National Laboratory is a nonthermal plasma technology created by a dielectric-ballasted electrical discharge. Influent gas-phase pollutants are destroyed in the reactor by the free radicals or electrons generated by the plasma. This paper examines the potential for SDP to be used in niche circumstances for POU control of VOC exhaust streams specific to the semiconductor industry. A sensitivity analysis is presented, showing how SDP cost of ...

1997-07-01

495

Continuous control of ionization wave chaos by spatially derived feedback signals  

CERN Document Server

In the positive column of a neon glow discharge, two different types of ionization waves occur simultaneously. The low-dimensional chaos arising from the nonlinear interaction between the two waves is controlled by a continuous feedback technique. The control strategy is derived from the time-delayed autosynchronization method. Two spatially displaced points of observation are used to obtain the control information, using the propagation characteristics of the chaotic wave.

1997-01-01

496

Battery using a metal particle bed electrode  

Energy Technology Data Exchange (ETDEWEB)

A zinc-air battery in a case including a zinc particle bed supported adjacent the current feeder and diaphragm on a porous support plate which holds the particles but passes electrolyte solution. Electrolyte is recycled through a conduit between the support plate and top of the bed by convective forces created by a density of differential caused by a higher concentration of high density discharge products in the interstices of the bed than in the electrolyte recycle conduit.

1991-01-01

497

Ambient water-quality criteria for ammonia (salt water)-1989  

Energy Technology Data Exchange (ETDEWEB)

Ammonia is a common and highly toxic pollutant which, in sufficient quantities, will adversely affect aquatic organisms. This ammonia criteria document for salt water will allow establishment of regulatory standards for ammonia discharge into estuaries, near coastal zones and oceans. Possible adverse impacts in highly sensitive and abundant ecosystems such as estuaries make regulation particularly important.

1989-04-01