WorldWideScience
1

Entering the Canadian mainstream. [The independent energy market in Canada  

Energy Technology Data Exchange (ETDEWEB)

This article examines the developing market for independent power projects in Canada. The topics of the article include bidding in Ontario, the Quebec market, powering British Columbia, and market forces at work in Canada. Discussed are current projects in all stages of completion from bidding to production and includes gas-fired cogeneration, gas-fired combined-cycle electricity generation and cogeneration, wood-waste fired plants, repowering of existing utility plants, and hydroelectric power plants.

1992-04-01

2

Hybrid Combined Cycles with Biomass and Waste Fired Bottoming Cycle - a Literature Study  

Energy Technology Data Exchange (ETDEWEB)

Biomass is one of the main natural resources in Sweden. The present low-CO{sub 2} emission characteristics of the Swedish electricity production system (hydro and nuclear) can be retained only by expansion of biofuel applications for energy purposes. Domestic Swedish biomass resources are vast and renewable, but not infinite. They must be utilized as efficiently as possible, in order to make sure that they meet the conditions for sustainability in the future. Application of efficient power generation cycles at low costs is essential for meeting this challenge. This applies also to municipal solid waste incineration with energy extraction, which should be preferred to its dumping in landfills. Hybrid dual-fuel combined cycle units are a simple and affordable way to increase the electric efficiency of biofuel energy utilization, without big investments, uncertainties or loss of reliability arising from complicated technologies. Configurations of ...

2002-02-01

3

Electric power generation. Thermal power generating systems. 2. rev. and enl. ed.  

International Nuclear Information System (INIS)

This is a manuscript for a lecture contents: 1. Steam power and fundamentals of the steam power process, 2. conventional, nuclear and other steam generation processes, 3. cooling systems for steam power plants, 4. gas turbine power plants and combined-cycle power plants, 5. cogeneration, 6. development of thermal power plants and environmental effects. (orig.).

4

Electric power generation. Thermal power generating systems  

International Nuclear Information System (INIS)

This is a manuscript for a lecture contents: 1) Steam power and fundamentals of the steam power process, 3) conventional, nuclear and other steam generation processes, 4) cooling systems for steam power plants, 5) gas turbine power plants and combined-cycle power plants, 6) cogeneration, 7) development of thermal power plants and environmental effects. (GL).

7

Achieving more reliable operation of turbine generators at nuclear power plants by improving the water chemistry of the generator stator cooling system  

British Library Electronic Table of Contents (United Kingdom)

Ways of improving the water chemistry used in the turbine generator stator?s cooling systems at Russian nuclear power plants are considered. Data obtained from operational chemical monitoring of indicators characterizing the quality of cooling water in the turbine generator stator cooling systems of operating power units at nuclear power plants are presented.

2011-01-01

8

Steam generator and condenser design of WWER-1000 type of nuclear power plant  

International Nuclear Information System (INIS)

Design process of steam generator and condenser at Russian nuclear power plant type WWER-1000 is identified. The four chapter of the books are organized as nuclear power plant, types of steam generators specially horizontal steam generator, process of steam generator design and the description of condenser and its process design.

1995-01-01

9

The electric power industry in Czechoslovakia - development and present state. Entwicklung und gegenwaertiger Stand der tschechoslowakischen Elektrizitaetswirtschaft  

Energy Technology Data Exchange (ETDEWEB)

Some general topical information (generating capacity and electric power generation, development and structure of electric power consumption, frequency and peak load, exchange of electricity) is followed by an account of the situation of coal-fired power plants, hydroelectric power plants and nuclear power plants, and a brief discussion of the environmental situation (emissions and wastes, immissions, and air pollution abatement measures for power plants). (orig./UA).

1992-11-02

10

Electrical grid stability and its impact on nuclear power generating stations  

Energy Technology Data Exchange (ETDEWEB)

Electrical power is generated by steam turbines (steam being produced by coal, oil, gas or nuclear reactors), hydro units, gas turbines, internal combustion engines, jet engines, and pumped storage plants. Nuclear Power Plants generate only 15% of the total electrical power in the US. Nuclear Power Plants being cheaper to run are generally base loaded. The pumped-storage and gas turbine plants have ideal characteristics for peaking duty. In the pumping mode, pumped storage plants are used to provide additional system load and in the generating mode, they supply reactive power during peak load demands. Gas turbine plants have higher running costs, but are used as peaking units with a fast start capability. Fossil power plants need a minimum of 1 hour to stabilize expansion in the boiler and turbine ...

1997-12-31

11

Hydroelectric and pumped storage plants  

Energy Technology Data Exchange (ETDEWEB)

All power plant engineers face the problem of peak power demands. Pumped storage plants are used to generate peak load power by pumping up water utilizing off-peak energy of hydrothermal and thermonuclear plants. This is the first accessible text/reference to cover hydroelectric power generation with emphasis on engineering to meet peak power demands by means of pumped storge plants, tidal power plants, and low head power generation. Text covers hydrology, mechanical and electrical equipment, accessories such as penstocks and valves, and civil engineering considerations. Contains descriptions of several existing plants. Includes 200 diagrams and 50 photographs.

1989-01-01

12

Hydroelectric and pumped storage plants  

Energy Technology Data Exchange (ETDEWEB)

All power plant engineers face the problem of peak power demands. Pumped storage plants are used to generate peak load power by pumping up water utilizing off-peak energy of hydrothermal and thermonuclear plants. This is a reference to cover hydroelectric power generation with emphasis on engineering to meet peak power demands by means of pumped storage plants, tidal power plants, and low head power generation. Text covers hydrology, mechanical and electrical equipment, accessories such as penstocks and valves, and civil engineering considerations. Contains descriptions of several existing plants. Includes 200 diagrams and 50 photographs.

1988-01-01

13

Environmental and health effects of fossil fuel and nuclear power generation  

International Nuclear Information System (INIS)

The objective of this study was to identify and assess the present and future dimensions of environmental effects and impacts of various energy generation alternatives, and to place safety and environmental risks associated with the nuclear industry in Canada in perspective with the risks from other sources. It was found that nuclear power generation involves a comparable risk to that of conventional methods of thermoelectric power generation.

1986-09-07

14

Gas turbines and steam turbines for power plants of the next generation; Gas- und Dampfturbinen fuer Kraftwerke der naechsten Generation  

Energy Technology Data Exchange (ETDEWEB)

Electricity is a universal energy and one of the driving powers of civilisation. World-wide, future developments like growing economies and structural changes in industry, a higher standard of living and a bigger world population - are impossible without appropriate supply of power and electricity. An expert of Siemens Power Generation presents his views. (orig.)

2006-11-15

15

Low temperature solar-to-electric power conversion system  

Science.gov (United States)

An electric power generating apparatus is described, including: a solar collector; a primary thermal loop including primary thermal fluid; a cavity receiver to receive reflected solar energy from the solar reflector, convert the solar energy into thermal energy, and transmit the thermal energy to the primary thermal fluid by heating the primary thermal fluid not to exceed a given temperature, the given temperature being substantially equal to 700 F; a Stirling engine receiving the primary thermal fluid heated by the cavity receiver, including means to generate mechanical power and means to generate electrical power from the means to generate mechanical power.

1993-07-20

16

Advanced Supercritical Carbon Dioxide Power Cycle Configurations for Use in Concentrating Solar Power Systems: Preprint  

Energy Technology Data Exchange (ETDEWEB)

The research will characterize and evaluate advanced S-CO2 Brayton cycle power generation with a modular power tower CSP system.

2011-03-01

17

Investigation of thermohydraulic processes in steam generators for nuclear power stations equipped with VVER reactors  

British Library Electronic Table of Contents (United Kingdom)

The results obtained from experimental investigations and mathematical simulation of horizontal steam generators are considered. Recommendations for continuing these works are given.

2006-01-01

18

Conception and design of steam power plants  

International Nuclear Information System (INIS)

The manual presents the fundamentals of thermodynamics and fluid mechanics, the main components of steam power plants, and the power generation process. The following concepts and subjects are discussed at length: steam generator; steam turbines; turbogenerators; condensers; cooling technology; water/steam cycle and water treatment; design data of fossil-fuelled power plants; design and optimisation of nuclear power plant thermodynamics; pipelines and fittings; control systems in steam power plants; connection to the electricity grid and self-supply of thermal power plants; power plant transformer concepts and definitions. (HAG).

19

Power generation growth to triple LNG use  

Energy Technology Data Exchange (ETDEWEB)

Taiwan`s LNG consumption is planned to rise more than threefold over the next four years as medium-term plans to develop power generation facilities increasingly rely on gas-fired combined-cycle stations to avoid the threat of power shortages. State-run Taiwan Power Company (Taipower) expects its LNG consumption to rise from 1.1 mn tonnes in 1996 to 3.4 mn tonnes in the year 2000. By then the first of several gas-fired private power stations is expected to enter service, further increasing Taiwan`s total LNG requirement for power generation. (Author)

1997-11-01

20

Engineering study on steam storage power generation. System screening and efficiency  

Energy Technology Data Exchange (ETDEWEB)

Large scale steam storage power generation, one of the new energy storage systems for the future of inflexible electric power sources consisting of nuclear and coal power plants has been studied on the subjects of the systems to be attached to coal and nuclear power units, of the definition of storage efficiency and of the vertical steam storage vessel technology. Steam storage power generation may be hopeful for its higher efficiency similarly defined as of pumped storage plants while high temperature heat storage and the internal structure of large vertical steam storage vessel (accumulator) need to be developed.

1981-11-01

21

Engineering study on steam storage power generation  

International Nuclear Information System (INIS)

Large scale steam storage power generation, one of the new energy storage systems for the future of inflexible electric power sources consisting of nuclear and coal power plants has been studied on the subjects of the systems to be attached to coal and nuclear power units, of the definition of storage efficiency and of the vertical steam storage vessel technology. Steam storage power generation may be hopeful for its higher efficiency similarly defined as of pumped storage plants while high temperature heat storage and the internal structure of large vertical steam storage vessel (accumulator) need to be developed. (author).

1981-01-01

22

Nuclear power plant personnel training in France  

International Nuclear Information System (INIS)

Data on French nuclear electricity generation sites, nuclear power plant operations personnel, operation simulators, nuclear training centers and training statistics are presented.

1994-03-21

24

Feedwater control device of the steam generator in an atomic power station  

International Nuclear Information System (INIS)

Purpose: In a case of automatically controlling the water level at the time of generating a lower power, to impact the followability of the control necessary for the power variation of the steam generator thereby to obtain good controllability. Constitution: A signal of deviation of water level of a steam generator and its set value and a signal of a difference between the temperature of the primary coolant in the high temperature side pipeline and that of the primary coolant in the low temperature side pipeline are used to automatically or manually control the flow quantity of water fed to the steam generator. (Yoshihara, H.).

25

The effect of deposits on the tubes of a horizontal steam generator on its thermal-hydraulic characteristics  

British Library Electronic Table of Contents (United Kingdom)

Analytical relations are obtained for estimating how the distributions of temperature and heat flux vary along a steam-generating tube and how the steam-generator power output reduces due to formation and accumulation of deposits.

2007-01-01

26

The effect of deposits on the tubes of a horizontal steam generator on its thermal-hydraulic characteristics  

Science.gov (United States)

Analytical relations are obtained for estimating how the distributions of temperature and heat flux vary along a steam-generating tube and how the steam-generator power output reduces due to formation and accumulation of deposits.

2007-12-01

27

Consideration of field experience in developing new projects of steam generators for nuclear power stations equipped with VVER reactors  

British Library Electronic Table of Contents (United Kingdom)

The main problems encountered during the operation of horizontal steam generators are considered. Design features of the new PGV-1000MK and PGV-1500 steam generators are analyzed.

2006-01-01

28

Steam generator tube failures: experience with water-cooled nuclear power reactors during 1976  

International Nuclear Information System (INIS)

A survey was conducted of experience with steam generator tubes at nuclear power stations during 1976. Failures were reported at 25 out of 68 water-cooled reactors. The causes of these failures and the repair and inspection procedures designed to cope with them are summarized. Examination of the data indicates that corrosion was the major cause of steam generator tube failures. Improvements are needed in steam generator design, condenser integrity and secondary water chemistry control. (author).

1994-10-18

29

Microturbine applications for the oil and gas industries of South America  

Energy Technology Data Exchange (ETDEWEB)

This paper will describe the application of power generation by the use of microturbine technology by Capstone Turbine Corporation throughout South America. The purpose of this paper is to describe the technology and the experience gained over the last six years. The microturbines are power generation systems that produce energy from a diverse range of liquid or gaseous fuels. The generator is driven by a small gas turbine with a common shaft for the rotors of the generator and the engine. (author)

2008-07-01

30

Implications of high temperature superconductors for power generation  

International Nuclear Information System (INIS)

Superconducting generators for high power applications have been of interest for a number of years. Superconducting generators using low temperature superconductors (LTS) have been manufactured to produce up to 20 MW of electrical power and have been configured in either synchronous alternators which have an AC output that may be subsequently rectified to produce DC and homopolar generators which produce low voltage DC. Typically these generators require scrupulous attention to vacuum integrity for cryogenic insulation at 4.2K and tend to be somewhat fragile because of extensive thermal and magnetic shields that are not required in conventional power generators. Recently, high purity aluminum composites have been developed for a high power AC generator that is cooled by cryogenic ...

1991-08-03

31

Application of power system stabilizer at Bandar-Abbas power station  

Energy Technology Data Exchange (ETDEWEB)

System instability as result of high power generation of one of the largest plants of the Iranian electric power grid prevented the plant to be fully utilized. PSSs were installed on the generating units of the power station, to improve its small signal stability, and enhance the stable generation limit. Domain separation and pole assignment techniques were applied for the PSS design. Several field tests were also carried out to verify its effectiveness. This paper presents the PSS tuning procedure, including the design criteria and some of the field test results.

1994-08-01

32

Effect of a pumped storage plant on the generation reliability of the Taiwan power system  

Energy Technology Data Exchange (ETDEWEB)

A novel approach to the reliability analysis of a power system with both hydro and pumped storage plants is presented in this paper. The proposed method is based on the concept of peak shaving for the hydro and pumped storage units. Different values of the stored energy of the pumped storage units are employed to demonstrate their effect on the generation reliability of a power system. The proposed scheme has been applied successfully to the reliability analysis of Taiwan power system.

1986-05-01

33

Stretch-out operation and extended low power operation in Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

Stretch-Out and Extended Low Power Operation is two particular operating modes applied for nuclear electricity generation. The relevant safety analysis and the impacts on plant operation are well illustrated, as well as some operation experiences earned in Daya Bay nuclear power station. The safety analysis and plant practice show that Stretch-Out operation and Extended Low Power Operation are operable in Daya Bay nuclear power station

2002-10-01

34

Procedure for operating reactors  

International Nuclear Information System (INIS)

The invention concerns a procedure for operating reactors in nuclear power plants. It aims at utilizing power reserves in nuclear power plants. This can be achieved by a steam-side connection of the steam generators of two reactors. The amount of steam exchanged between the units is chosen in such a way that power changes at the steam turbines feedback mainly to the corresponding reactor. In order to realize a high power transfer it is necessary to return the amount of condensate produced in the steam receiving unit and corresponding to the power transferred to the feedwater system of the steam donating unit.

1985-11-11

35

Particle Swarm Optimization Based Reactive Power Optimization  

CERN Document Server

Reactive power plays an important role in supporting the real power transfer by maintaining voltage stability and system reliability. It is a critical element for a transmission operator to ensure the reliability of an electric system while minimizing the cost associated with it. The traditional objectives of reactive power dispatch are focused on the technical side of reactive support such as minimization of transmission losses. Reactive power cost compensation to a generator is based on the incurred cost of its reactive power contribution less the cost of its obligation to support the active power delivery. In this paper an efficient Particle Swarm Optimization (PSO) based reactive power optimization approach is presented. The optimal reactive power dispatch problem is a nonlinear optimization ...

2010-01-01

36

Transient stability enhancement of electric power generating systems by 120-degree phase rotation  

Energy Technology Data Exchange (ETDEWEB)

A method and system for enhancing the transient stability of an intertied three-phase electric power generating system. A set of power exporting generators (10) is connected to a set of power importing generators (20). When a transient cannot be controlled by conventional stability controls, and imminent loss of synchronism is detected (such as when the equivalent rotor angle difference between the two generator sets exceeds a predetermined value, such as 150 degrees), the intertie is disconnected by circuit breakers. Then a switch (30) having a 120-degree phase rotation, or a circuit breaker having a 120-degree phase rotation is placed in the intertie. The intertie is then reconnected. This results in a 120-degree reduction in the equivalent rotor angle difference between the two generator sets, making the system more ...

1982-01-01

37

The relation between maturity and sophistication shall be properly dealt with in nuclear power development  

International Nuclear Information System (INIS)

The paper analyses the advantages and disadvantages of the second generation improved technologies and third generation technologies mainly developed in China in terms of safety and economy. The paper also discusses the maturity of the second generation improved technologies and the sophistication of the third generation technologies respectively. Meanwhile, the paper proposes that the advantage and disadvantage of second generation improved technologies and third generation technologies should be carefully taken into consideration and the relationship between the maturity and sophistication should be properly dealt with in the current stage. A two-step strategy shall be taken as a solution to solve the problem of insufficient capacity of nuclear power, trace and develop the third generation technologies, so as to ensure ...

2009-06-01

38

Steam generators ? horizontal or vertical (which type should be used in nuclear power plants with VVER?)  

British Library Electronic Table of Contents (United Kingdom)

The steam generator is a very important component of a nuclear power plant. Historically, vertical steam generators came to be used abroad and horizontal steam generators in our country. Both types of steam generators operate successfully in nuclear power plants and satisfactorily fulfill their functions, enabling the production of electricity. Repeated attempts to re-examine the existing concepts in one or another country have been unsuccessful because there are no convincing arguments for this. Nonetheless, the question of using a different type of steam generator is raised periodically in our country and abroad. This article briefly reviews different concepts of steam generators. Their parameters, characteristics, and thermal efficiency are compared and ways to increase the latter are a...

2008-01-01

39

Experience with the identification and tuning of excitation system parameters at the second nuclear power plant of Taiwan Power Company  

Energy Technology Data Exchange (ETDEWEB)

Experience with the identification and tuning of exciter constants for a generating unit as the Second Nuclear Power Plant of Taiwan Power Company is reported. Field test is first performed on the excitation system with the generator open-circuited. Since the field test results differ from the computer simulation results using manufacturer`s constants, the authors first modify the manufacturer`s constants based on their previous experience to reach a preliminary set of parameters for the excitation system. Then a hybrid nonlinear simulation-sensitivity matrix method is developed to further refine the excitation system parameters. The exciter constants are tuned in order to give better dynamic response before a power system stabilizer is applied to the generator. Field tests are then performed in order to compare the dynamic response of the ...

1996-05-01

40

Experience with the identification and tuning of excitation system parameters at the second nuclear power plant of Taiwan Power Company  

International Nuclear Information System (INIS)

Experience with the identification and tuning of exciter constants for a generating unit as the Second Nuclear Power Plant of Taiwan Power Company is reported. Field test is first performed on the excitation system with the generator open-circuited. Since the field test results differ from the computer simulation results using manufacturer's constants, the authors first modify the manufacturer's constants based on their previous experience to reach a preliminary set of parameters for the excitation system. Then a hybrid nonlinear simulation-sensitivity matrix method is developed to further refine the excitation system parameters. The exciter constants are tuned in order to give better dynamic response before a power system stabilizer is applied to the generator. Field tests are then performed in order to compare the dynamic response of the ...

1995-07-23

41

Fast generation shedding equipment based on the observation of swings of generators  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a new method and newly developed stabilizing equipment to prevent the loss of synchronism of generators in pumped-storage plants from spreading. The proposed method includes functions to estimate the swing of each generator by using on-line generator output sampled at a rate of 600 times per second after an occurrence of disturbance such as fault, faulty equipment and so on, to predict generator swing 200-300 milliseconds ahead and loss of synchronism between generators in pumped-storage plants and those in thermal and nuclear plants, and to decide the number of generators that must be shed to maintain stability. Tokyo Electric Power Co. (TEPCO) installed the newly developed stabilizing equipment based on this method in the power system in June, 1986.

1988-05-01

42

Fast generation shedding equipment based on the observation of swings of generators  

International Nuclear Information System (INIS)

This paper presents a new method and newly developed stabilizing equipment to prevent the loss of synchronism of generators in pumped-storage plants from spreading. The proposed method includes functions to estimate the swing of each generator by using on-line generator output sampled at a rate of 600 times per second after an occurrence of disturbance such as fault, faulty equipment and so on, to predict generator swing 200-300 milliseconds ahead and loss of synchronism between generators in pumped-storage plants and those in thermal and nuclear plants, and to decide the number of generators that must be shed to maintain stability. Tokyo Electric Power Co. (TEPCO) installed the newly developed stabilizing equipment based on this method in the power system in June, 1986.

1988-01-01

43

Short term hydroelectric power system scheduling with wind turbine generators using the multi-pass iteration particle swarm optimization approach  

British Library Electronic Table of Contents (United Kingdom)

This paper uses multi-pass iteration particle swarm optimization (MIPSO) to solve short term hydroelectric generation scheduling of a power system with wind turbine generators. MIPSO is a new algorithm for solving nonlinear optimal scheduling problems. A new index called iteration best (IB) is incorporated into particle swarm optimization (PSO) to improve solution quality. The concept of multi-pass dynamic programming is applied to modify PSO further and improve computation efficiency.The feasible operational regions of the hydro units and pumped storage plants over the whole scheduling time range must be determined before applying MIPSO to the problem. Wind turbine power generation then shaves the power system load curves. Next, MIPSO calculates hydroelectric generation scheduling. It beg...

2008-01-01

44

Smart start for smart grids. Intelligent solutions for overall power generation management; Smarter Start fuer Smart Grids. Intelligente Loesungen fuer ein kraftwerkuebergreifendes Erzeugungsmanagement  

Energy Technology Data Exchange (ETDEWEB)

The go ahead for setting up the Smart Grid has been given - on the consumer side, for example, in the form of intelligent electricity meters (Smart Meter). It will be some years, however, before a comprehensive and integrated generation, transport and consumer concept can be implemented. An integral part of this implementation concept will be intelligent energy systems that coordinate individual local power grids and thus ensure optimum exploitation of the power generated. But even without full grid networking energy management can be shaped more intelligently - for example by combining and optimising the power generation capacities of several power plant locations and energy carriers. (orig.)

2010-07-01

45

Water chemistry and corrosion in water-steam circuits of nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

The water and steam circuits of steam generators in pressurized-water nuclear power plants are described together with the mechanism of denting, and the corrosion of spacer plates that leads to cracks in tubes by constriction. The different chemical specifications applicable to the water of the secondary circuit of the generators in normal operation and on first commissioning are listed. The results obtained and the measurements of chemical values taken in operation on the water in the secondary circuits of steam generators at Fessenheim and Bugey are presented.

1981-05-01

46

Water chemistry and corrosion in water-steam circuits of nuclear power plants  

International Nuclear Information System (INIS)

The water and steam circuits of steam generators in pressurized-water nuclear power plants are described together with the mechanism of denting, and the corrosion of spacer plates that leads to cracks in tubes by constriction. The different chemical specifications applicable to the water of the secondary circuit of the generators in normal operation and on first commissioning are listed. The results obtained and the measurements of chemical values taken in operation on the water in the secondary circuits of steam generators at Fessenheim and Bugey are presented.

47

European Space Power Conference  

International Nuclear Information System (INIS)

To support the Space Exploration Initiative (SEI), a study was performed to investigate power system alternatives for the rover vehicles and servicers that were subsequently generated for each of these rovers and servicers, candidate power sources incorporating various power generation and energy storage technologies were identified. The technologies were those believed most appropriate to the SEI missions, and included solar, electrochemical, and isotope systems. The candidates were characterized with respect to system mass, deployed area, and volume. For each of the missions a preliminary selection was made. Results of this study depict the available power sources in light of mission requirements as they are currently defined.

1991-09-02

48

International water power and dam construction yearbook 1996  

Energy Technology Data Exchange (ETDEWEB)

This document draws together data on hydroelectric power generation and dam construction for 1996. Machinery such as turbines and hydroelectric generators are listed together with their manufacturers. Contact addresses for international organizations concerned with water power are listed. Listings are also given for hydro resources worldwide, and the global distribution of pumped-storage plants, dams and hydroelectric plants. Company data is also listed providing a buyer`s guide for 1996. (UK)

1996-12-31

49

Implementation and laboratory test results for an adaptive Power System Stabilizer based on linear optimal control  

Energy Technology Data Exchange (ETDEWEB)

Implementation of an adaptive power system stabilizer (PSS) based on linear optimal control is described in this paper. The generator is identified in real time, and a special 3rd order discrete Riccati equation is solved in each sample interval. Because the output of the generator is fed back directly, the controller can track the system very fast. Experimental studies on a physical model of a power system demonstrate the effectiveness of the proposed adaptive optimal controller.

1990-12-01

50

Electrical equipment of the Marchtrenk power station on the river Traun  

Energy Technology Data Exchange (ETDEWEB)

By way of introduction, the author describes the electrical equipment of the power station on the River Traun and then lists the main features of the electrical systems such as generators, transformers, the power transmission systems as, e.g., the generator leads, the 8 kV switch plant, the 110 kV oil-filled cable as well as the station-service, control, protection and monitoring systems. The control of the headwater level and of the mechanical systems of the barrage is described in detail.

1982-03-01

51

A self-tuning Power System Stabilizer for wide-range synchronous generator operation  

Energy Technology Data Exchange (ETDEWEB)

A self-tuning Power System Stabilizer (PSS) is suggested in this paper. Computer simulations, of a lightly-damped single turbine-generator supplying power to an infinite bus system, show that this self-tuning PSS can work over a large operating range and make a significant improvement in rotor damping.

1989-08-01

52

Climate change/variability implications on hydroelectricity generation in the Zambezi River Basin  

British Library Electronic Table of Contents (United Kingdom)

The study has analysed the effects of various factors on hydroelectric power generation potential to include climate change/variability, water demand, and installation of proposed hydroelectric power schemes in the Zambezi River Basin. An assessment of historical (1970?2000) power potential in relation to climate change/variability at existing hydro electric power schemes(Cahora Bassa, Kariba, Kafue Gorge and Itezhi-Tezhi) in the Zambezi River Basin was conducted. The correlation of hydroelectric power potential with climate change/variability aimed at observing the link and extent of influence of the latter on the former was investigated. In order to predict the future outlook of hydro electric power potential, General Circulation Models (GCM) were used to generate projected precipitation...

2011-01-01

53

Hydroelectric power in Switzerland: large growth potential by increasing the installed power  

International Nuclear Information System (INIS)

Due to its important hydroelectric power generation facilities (about 525 plants with a total power of 13,314 MW producing about 35.3 TWh annually) Switzerland plays an important role in the interconnected European power system. Large artificial storage lakes in the Swiss Alps can generate peak power during hours of highest demand: 9700 MW are available from accumulated energy and the total power of pumped-storage facilities amounts to 1700 MW. The latter allow refilling the reservoirs at periods of low power demand and generating power at periods of peak demand. In the case of favorable conditions, the yearly average power production could be increased by 6% and the production during the winter period (October to March) by 20% by the year 2020. However, ...

54

Three-dimensional power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

Power system stabilizers (PSSs) are used to enhance damping of power system oscillations through excitation control of synchronous generator. The objective of the PSS is to generate a stabilizing signal, which produces a damping torque component on the generator shaft. Conventional PSSs are designed with the phase compensation technique in the frequency domain and include the lead-lag blocks whose parameters are determined according to a linearized power system model. The performance of conventional PSSs (CPSSs) depends upon the generator operating point and the system parameters, but a reasonable level of robustness can be achieved depending on the tuning method. This paper presents a new three-dimensional PSS (3D PSS), which uses rotor speed deviation, rotor acceleration and load angle deviation as input signals. The 3D PSS attempts to ...

2010-07-15

55

Combined power generation with wind and ocean waves  

Energy Technology Data Exchange (ETDEWEB)

It is often advantageous to generate power with combinations of wind and ocean waves. In fact ocean waves, their generation, propagation, dissipation are directly related to wind velocity and its duration oven the sea. In this paper an attempt has been made to demonstrate statistically to present some advantages with combined wind and ocean wave power generation. Even though many conceptual techniques and methods are possible to harness combined power generation, it is important to test feasibility of combined output as well as individual outputs mathematically. One of the major advantages of combined wind and wave power generation is to improve probability of continuous power supply (it minimises the interruptions and compensates power fluctuations with one ...

1996-09-01

56

Thermal-hydraulic characteristic of the PGV-1000 steam generator  

International Nuclear Information System (INIS)

Horizontal steam generators are typical parts of nuclear power plants with pressure water reactor type VVER. By means of this computer program, a detailed thermal-hydraulic study of the horizontal steam generator PGV-1000 has been carried out and a special attention has been paid to the thermal-hydraulics of the secondary side. A set of important steam generator characteristics has been obtained and analyzed. Some of the interesting results of the analysis are presented in the paper. (author)

1995-09-11

57

Numerical investigation of three-dimensional flows of steam-water mixture in the housing of the PGV-1000 steam generator  

British Library Electronic Table of Contents (United Kingdom)

Results are given of numerical simulation of three-dimensional pattern of flow of a two-phase steam-water mixture in the house of a PGV-1000 horizontal steam generator obtained using the BAGIRA best-estimate thermohydrodynamic computer codes. The space distributions of velocities and local void fractions in the steam generator housing for different modes of operation of power-generating unit are calculated and compared with available experimental data.

2008-01-01

58

Numerical investigation of three-dimensional flows of steam-water mixture in the housing of the PGV-1000 steam generator  

Science.gov (United States)

Results are given of numerical simulation of three-dimensional pattern of flow of a two-phase steam-water mixture in the house of a PGV-1000 horizontal steam generator obtained using the BAGIRA best-estimate thermohydrodynamic computer codes. The space distributions of velocities and local void fractions in the steam generator housing for different modes of operation of power-generating unit are calculated and compared with available experimental data.

2008-05-01

59

Modeling of a horizontal steam generator for the submerged nuclear power station concept  

Energy Technology Data Exchange (ETDEWEB)

A submerged nuclear power station has been proposed as an alternative power station with a relatively low environmental impact for use by both industrialized and developing countries. The station would be placed 10 m above the seabed at a depth of 30--100 m and a distance of 10--30 km from shore. The submerged nuclear power station would be manufactured and refueled in a central facility, thus gaining the economies of factoryfabrication and the flexibility of short-lead-time deployment. To minimize the size of the submerged hull, horizontal steam generators are proposed for the primary-to-secondary heat transfer, instead of the more traditional vertical steam generators. The horizontal steam generators for SNPS would be similar in design to the horizontal steam generators used in the N-Reactors except the tube orientation is horizontal (the ...

1993-01-01

60

Modeling of a horizontal steam generator for the submerged nuclear power station concept  

Energy Technology Data Exchange (ETDEWEB)

A submerged nuclear power station has been proposed as an alternative power station with a relatively low environmental impact for use by both industrialized and developing countries. The station would be placed 10 m above the seabed at a depth of 30--100 m and a distance of 10--30 km from shore. The submerged nuclear power station would be manufactured and refueled in a central facility, thus gaining the economies of factoryfabrication and the flexibility of short-lead-time deployment. To minimize the size of the submerged hull, horizontal steam generators are proposed for the primary-to-secondary heat transfer, instead of the more traditional vertical steam generators. The horizontal steam generators for SNPS would be similar in design to the horizontal steam generators used in the N-Reactors except the tube orientation is horizontal (the ...

1993-05-01

61

Modeling of a horizontal steam generator for the submerged nuclear power station concept  

International Nuclear Information System (INIS)

A submerged nuclear power station has been proposed as an alternative power station with a relatively low environmental impact for use by both industrialized and developing countries. The station would be placed 10 m above the seabed at a depth of 30--100 m and a distance of 10--30 km from shore. The submerged nuclear power station would be manufactured and refueled in a central facility, thus gaining the economies of factoryfabrication and the flexibility of short-lead-time deployment. To minimize the size of the submerged hull, horizontal steam generators are proposed for the primary-to-secondary heat transfer, instead of the more traditional vertical steam generators. The horizontal steam generators for SNPS would be similar in design to the horizontal steam generators used in the N-Reactors except the tube orientation is horizontal (the ...

1993-07-06

62

Computer code analysis of steam generator in thermal-hydraulic test facility simulating nuclear power plant.  

Science.gov (United States)

In the study three loss-of-feedwater type experiments which were preformed with the PACTEL facility has been calculated with two computer codes. The purpose of the experiments was to gain information about the behaviour of horizontal steam generator in a ...

1995-01-01

63

The alkali sorption process by solid sorbents at high temperature  

Energy Technology Data Exchange (ETDEWEB)

The removal of toxic metals and alkalis from gas streams at high temperatures was investigated. This is important for the development of coal-fired combined cycle power generation systems.

2000-03-01

64

Palladium- and Copper-Catalyzed Arylation of Carbon-Hydrogen Bonds  

UK PubMed Central (United Kingdom)

The transition-metal-catalyzed functionalization of C-H bonds is a powerful method for generating carbon-carbon...Full Text Available

2009-08-18

65

Economic analysis of nuclear power generation  

Energy Technology Data Exchange (ETDEWEB)

The major contents in this study are as follows : - long-term forecast to the year of 2040 is provided for nuclear electricity generating capacity by means of logistic curve fitting method. - the role of nuclear power in a national economy is analyzed in terms of environmental regulation. To do so, energy-economy linked model is developed. By using this model, the benefits from the introduction of nuclear power in Korea are estimated. Study on inter-industry economic activity for nuclear industry is carried out by means of an input-output analysis. Nuclear industry is examined in terms of inducement effect of production, of value-added, and of import. - economic analysis of nuclear power generation is performed especially taking into consideration wide variations of foreign currency exchange rate. The result is expressed in levelized generating costs. (author). ...

1997-12-01

66

EMFs: cutting through the controversy.  

UK PubMed Central (United Kingdom)

SOME SCIENTISTS ALLEGE that exposure to electric and magnetic fields generated by electric power delivery systems is responsible for certain cancers (particularly among children), reproductive dysfunction,...Full Text Available

1996-05-01

67

Development of a New Generation of Small Scale Biomass ...  

Science.gov (United States)

... power from wood and bagasse as well as convert non-traditional fuel sources such as rice bulls, animal manure, cotton gin trash, straws, and ...

1995-08-01

68

A Theoretical Solid Oxide Fuel Cell Model for Systems Controls and Stability Design  

Science.gov (United States)

As the aviation industry moves toward higher efficiency electrical power generation, all electric

2008-01-01

69

2010 power generation sector restructuring in Romania-A critical assessment  

International Nuclear Information System (INIS)

In the spring of 2009, the Romanian government has proposed a restructuring of the national power generation sector segment that is still owned by the state. As most of the power generation capacity is still state-owned, this restructuring will dramatically alter the competitive landscape of this sector. This paper is analyzing the rationale and principles of the restructuring as stated by government documents and officials, the assessment methodology and criteria proposed by the government, as well as the proposed final outcome of the restructuring initiative. Based on this critical assessment and the early results of the restructuring's implementation, we are able to make recommendations that can be considered for a revised restructuring approach. - Research highlights: #-># Power generation sector restructuring is proposed in 2009 by the Romanian ...

2011-03-01

70

Classes of KWU steam turbines  

International Nuclear Information System (INIS)

For the conversion of thermal energy into electric energy in modern condenser power plants, according to the way of steam generation, two different types of power stations are built: power stations for fossile fuels and nuclear power stations. Also two classes of steam turbines were developed, corresponding to the two power station types, whose steam conditions, by experience and extensive calculations of economy, were determined so that a minimum of power generating cost will result. The two classes, the HMN and the SN series, are composed according to the modular system and designed in such a manner that with a small number of standard components, steam turbines for the power range between 100 and 2,500 MW can be built. (orig.).

71

Biofuels for electricity and heating - obstacles for increased utilization  

International Nuclear Information System (INIS)

The aim of this report is to describe the present situation regarding biomass utilization in small power plants, 0.5 - 20 MW fuel power. Also discussed are the most important technical, economical and environmental conditions which may prevent a fast expansion of small biomass fueled power plants for generation of district heating in smaller networks and also for electric power generation. Biofuels means a reduction of the net emission of carbon dioxide, but emission of other compounds are not very well known for this size of power plants. There are only a few biofueled power plants in Sweden and only a couple with less than 20 MW power supplied. New concepts are under development but not much have been achieved during the most recent years. 25 refs, 10 figs, 9 tabs.

72

Design and performance of radioisotope space power systems based on OSC multitube AMTEC converter designs  

Energy Technology Data Exchange (ETDEWEB)

This paper extends the analytical procedure described in another paper in these proceedings to analyze a variety of compact and light-weight OSC-designed radioisotope-heated generators. Those generators employed General Purpose Heat Source (GPHS) modules and a converter containing sixteen AMTEC cells of OSC`s revised five-tube design with enhanced cell wall reflectivity described in a companion paper in these proceedings. OSC found that the performance of the generator is primarily a function of the thermal insulation between the outside of the generator`s 16 cells and the inside of its wall. After examining a variety of insulation options, it was found that the generator`s performance is optimized by employing a hybrid insulation system, in which the space between the cells is filled with fibrous Min-K insulation, and the generator walls are lined with tapered ...

1997-12-31

73

300 W polymer electrolyte fuel cell generators for educational purposes  

Energy Technology Data Exchange (ETDEWEB)

A 300 W fuel cell power pack has been developed for educational purposes in close collaboration with the Fachhochschule Solothurn Nordwestschweiz. The project was initiated and financed by the Swiss Federal Office of Energy. The outlay and the performance of the power pack are described. (author) 3 figs.

1999-08-01

74

High-power radio frequency pulse generation and extraction based on wakefield excited by an intense charged particle beam in dielectric-loaded waveguides  

International Nuclear Information System (INIS)

Power extraction using a dielectric-loaded (DL) waveguide is a way to generate high-power radio frequency (RF) waves for future particle accelerators, especially for two-beam-acceleration. In a two-beam-acceleration scheme, a low-energy, high-current particle beam is passed through a deceleration section of waveguide (decelerator), where the power from the beam is partially transferred to trailing electromagnetic waves (wakefields); then with a properly designed RF output coupler, the power generated in the decelerator is extracted to an output waveguide, where finally the power can be transmitted and used to accelerate another usually high-energy low-current beam. The decelerator, together with the RF output coupler, is called a power extractor. At Argonne Wakefield Accelerator (AWA), we designed a 7.8GHz ...

75

Improvement of power system stability by high speed power control of adjustable speed machine; Kahensokuki no koshutsuryoku seigyo ni yoru denryoku keito no anteido kojo  

Energy Technology Data Exchange (ETDEWEB)

Large capacity adjustable speed machines (ASMs) at pumped storage power station have been put into full operation and the operating characteristics of ASM have been highly evaluated from the view point of power system operation. The output power (input power) of ASM can be controlled very quickly by applying a vector control scheme to the excitation control. This quick responsive feature of ASM can make it possible to improve the stability of the neighbor sub-power system. For improvement of transient stability, the output power of ASM is reduced very quickly in order to control the acceleration of neighbor generators during and after transmission line faults. For improvement of dynamic stability, the output power of ASM is modulated in accordance with the stabilizing signals detected from the swing of ...

1997-01-20

76

Financing `Orbital Power and Light Inc`  

Energy Technology Data Exchange (ETDEWEB)

Financing space solar power generation programmes has several inherent difficulties. Such large-scale projects are usually easily defined with an expected economic return, construction time, useful service life and defined management structure. As yet, solar power satellites for power generation possess none of these as the idea exists conceptually and the technology still needs to be developed. Methods for overcoming these uncertainties and securing financial backing are described. Venture capital could finance a research/marketing firm. US Government support through a cost plus short-term monopoly to facilitate private debt financing could provide an answer. (UK)

1998-06-01

77

Comments on open-ended magnetic systems for fusion  

Energy Technology Data Exchange (ETDEWEB)

Differentiating characteristics of magnetic confinement systems having externally generated magnetic fields that are open'' are listed and discussed in the light of their several potential advantages for fusion power systems. It is pointed out that at this stage of fusion research high-Q'' (as deduced from long energy confinement times) is not necessarily the most relevant criterion by which to judge the potential of alternate fusion approaches for the economic generation of fusion power. An example is given of a hypothetical open-geometry fusion power system where low-Q operation is essential to meeting one of its main objectives (low neutron power flux).

1990-09-24

78

Rethinking development assistance for wind power  

Energy Technology Data Exchange (ETDEWEB)

Electricity generation from wind turbines is now cost competitive for grid and off-grid applications in many developing regions, and close to competitive in others. Wind resources could generate thousands of megawatts of badly-needed power in Asia, North Africa, and Latin America. Barriers to penetrating power generation markets remain, however, including unequal access to investment capital, energy price and other market distortions, and often weak institutions for commercializing new technologies. Recognizing the potential economic and environmental benefits of wind power, bilateral and multilateral assistance organizations have for several years offered financial and technical assistance to promote its diffusion. Based on this experience and assistance for other renewable electric technologies, lessons and recommendations can be drawn regarding how assistance ...

1995-12-31

79

An efficient algorithm for the design of decentralized output feedback power system stabilizer  

Science.gov (United States)

A new algorithm for the design of decentralized output feedback stabilizers for large-scale electric power systems is presented in this paper. In the proposed approach, the generators which are most effective for stabilizer applications are first identified by using participation factors. Then an efficient algorithm based on decentralized pole assignment is proposed for the determination of the parameters of the power system stabilizers which, due to the difficulty associated with the communication among the geographically dispersed generating stations in a large power system, are essentially decentralized compensators using local generator outputs as their feedback signals. The proposed method is computationally efficient and can be applied to any large-scale system. The simplicity and effectiveness of the proposed method are demonstrated by an example of ...

1988-08-01

80

Multi-megawatt space power reactors  

Energy Technology Data Exchange (ETDEWEB)

In response to the need of the Strategic Defence Initiative (SDI) and long range space exploration and extra-terrestrial basing by the National Air and Space Administration (NASA), concepts for nuclear power systems in the multi-megawatt levels are being evaluated. The requirements for these power systems are being driven primarily by the need to minimize weight and maximize safety and reliability. This paper discusses the present requirements for space based advanced power systems, technological issues associated with the development of these advanced nuclear power systems, and some of the concepts proposed for generating large amounts of power in space. (author).

1990-01-01

81

Assessing the profitability of reactive power compensation devices  

Energy Technology Data Exchange (ETDEWEB)

A probabilistic method for assessing the profitability of reactive power compensation devices such as capacitors, static VAR compensators and generators, which improve network security, was described. Since network development is limited by environmental constraints, power networks are operated close to their limits. Because of this fact transmission network planning increasingly relies on techno-economic models to improve network security and profitability. The proposed method consists of analyzing large numbers of constrained power system states, extracted from power system simulation exercises. The paper describes details of the method and provides an example of a numerical application on a part of the French power transmission system. 10 refs., 8 figs.

1997-12-31

82

Fuel cells and electricity companies - new risk management opportunities  

International Nuclear Information System (INIS)

'Full text:' Deregulation, distributed generation, combined heat and power, renewables, fuel cells, hydrogen. Power companies are facing a rapidly evolving environment that is testing their ability to effectively deploy capital and earn profits. While recent deregulation trends have shifted the structure of power markets into separating generators from distributors, the improving economic value proposition offered by smaller scale distributed generation technologies - such as fuel cells - would seem to be a conflicting development. In this complex and changing environment, decisions based on the economic reality of the capital markets are likely to prevail. By examining the opportunity to enhance risk management offered by stationary fuel cells, particularly in CHP applications, we provide a context for the issues being discussed in today's sessions focusing on ...

2004-09-25

83

Status of electric power in the Missouri River Basin  

Energy Technology Data Exchange (ETDEWEB)

This third Missouri River Basin Commission report on Status of Electric Power in the Missouri River Basin provides information on the status of electric power generation, future needs, and potentials for meeting these needs. Information for this 1980 update is based upon available published information up to and including December 31, 1979. State and federal members of the Missouri River Basin Commission provided information for sections of the report and on legislative activities. Information is included on the planning and projected costs of hydro, nuclear and fossil-fuel power plants, pumped-storage plants, transmission systems, projected power demands, the environmental, socio-economic-cultural impacts of electric power generation, and regulations affecting energy development. (LCL)

1980-01-01

84

Five TWh saved on profitable upgrading  

International Nuclear Information System (INIS)

Article. In Norway, a project is planned to evaluate the upgrading potential of the hydroelectric power sector. The article criticizes the authorities for not supporting the upgrading of hydroelectric power plants in their eager to promote the development of wind power. An important contribution of the planned project will be a book from which the utilities may get advice on measures of upgrading. Generators and control systems account for 80% of the faults and interruptions in the power utilities. The turbine technology has made important progress in the 1990s. By pure upgrading measures alone, the turbine efficiencies may be increased enough for an additional 3 TWh to be taken out from the Norwegian hydroelectric power system. Today, the price of imported carbon-based Danish power determines whether the utilities find it profitable to ...

85

Second harmonic generation of copper-vapor pulsed laser radiation  

Energy Technology Data Exchange (ETDEWEB)

An experimental study of second harmonic generation in a copper-vapor pulsed laser with an ADP crystal is presented. The ratio of the conversion into the second harmonic is found to depend on the average power of the exciting radiation. The maximum conversion ratio was 8.5%. Thermal self-defocusing is the main obstacle to obtaining high average powers at the double frequency.

1980-08-01

86

Nuclear power generation. Chapter 14  

International Nuclear Information System (INIS)

As part of a handbook on the efficient use of energy a chapter is included which is intended to give an appreciation of the principles and problems involved in the generation of nuclear power. The subject is discussed under the following headings: introductory nuclear physics; basic reactor physics; thermal reactors; fast reactors; fuel reserves and utilization; environmental considerations; nuclear fusion. (U.K.).

1975-01-01

87

Improved control of fuel crushing in coal-fired power stations  

Energy Technology Data Exchange (ETDEWEB)

With the frequent load changes to which a hard coal power station is subjected in the middle and peak load range, great demands are linked with the transient behaviour of the steam generator. Due to the serial connection of the crusher and boiler, the strongly delaying transient behaviour of the crusher compounds entirely with the transient behaviour of the steam generator. Therefore, a suggestion is to be made here as to the improvement of the dynamics of the crusher.

1988-01-01

88

Private power in the country -- a chronology  

Energy Technology Data Exchange (ETDEWEB)

The chronology of installing solar power in a rural area of Ontario is described. The installation took all of seven years, and was characterized by a lot of joy, but also a lot of heartache and hardship, all of which are chronicled in this article. The project started with four solar modules generating 300 watts, nickel cadmium batteries of 225 Ah, an inverter of 600 watt, and a three-cylinder 6.5 Kw water-cooled propane generator. Today, nearly seven years later, the installation consists of 18 solar modules supplying 1350 watts of power, lead-acid batteries of 2770 Ah, a 2500 watt inverter, a one cylinder, 5.5 kw propane-gasoline generator, a heated, underground generator house, complete with an amp-hour meter and MPPT charge controller.

2003-06-30

89

Exergoeconomic analysis of the power generation system using blast furnace and coke oven gas in a Brazilian steel mill  

British Library Electronic Table of Contents (United Kingdom)

The rational use of energy has become a priority for all industries in Brazil, mainly after the energy rationing in 2001. Methodologies to quantify and improve the performance of plants that consume and generate electricity and thermal energy are being used to reach this goal. Exergoeconomic analysis provides a complete diagnosis of a plant, both in exergetic and in monetary values. This study shows the methodology used to assess the power generation system of the Companhia Siderurgica Tubarao (CST). The current system is based on a regenerative Rankine cycle using two gases from steel production - blast furnace gas (BFG) and coke oven gas (COG) - to generate electric power and occasionally steam for the process. Use of the Theory of Exergetic Cost allowed determination of monetary and exe...

2009-01-01

90

The ageing of CANDU steam generator due to localized corrosion  

International Nuclear Information System (INIS)

The Steam Generator (SG) tubing degradation caused by corrosion and other age-related mechanisms continues to be a significant safety and cost concern for many Nuclear Power Plants (NPP). The understanding of the steam generator ageing mechanisms is the key to effective management of steam generator ageing and consists of the knowledge of steam generator materials and these one properties, stressors and operating conditions, like degradation sites and wear mechanisms. The principal types of corrosion are presented which can occur in CANDU steam generator. There are also presented the operation conditions, the specifications referring to the water chemistry and the construction materials of Steam Generator, the factors that have a great influence on the corrosion behaviour during the whole exploitation period of this equipment. (R.P.)

2001-09-17

91

Demonstration test of power system stabilizer employing fuzzy theory; Fuzzy riron wo tekiyoshita keito anteika sochi o jissho shiken hokoku  

Energy Technology Data Exchange (ETDEWEB)

The demonstration test of a power system stabilizer, employing a fuzzy theory, in the two hydroelectric power stations of Kyusyu Electric Power Co., Inc. is described. The PSS inputs auxiliary signals to the automatic voltage regulator (AVR) of a generator and generates an electric torque in the direction opposite to the operating direction of a generator to enhance the damping effect and improve the system stability. Usually, the change in the slide information of a generator is detected, and the phase adjustment is performed so that the damping is the optimum value. However, since the damping is optimized in the specific system state, no complete damping may be obtained when the system state is changed. A fuzzy theory was thus applied for the control operation part. In a secondary fuzzy PSS, the velocity and acceleration were calculated ...

1997-03-01

92

Gas turbines aim at world power market dominance  

Energy Technology Data Exchange (ETDEWEB)

Rapid technology improvements, resulting in high efficiency, emissions reduction and low generation cost, are making gas turbines the generation technology of choice despite some recent reliability problems. The basic reason for the dominance is high efficiency. The rapid pace of gas-turbine technology improvement in the 1990s drove combined-cycle thermal efficiency to nearly 60 percent with natural gas as the fuel. It will probably go even higher after the year 2000. In addition, the gas-fired combined cycle is a bargain. With natural gas prices where they are right now, it is the least-cost generation operation for power producers with access to gas. Many will replace older, high-cost power plants with new gas-fired combined cycle power plants.

1996-06-01

93

Design of power system stabilizer through state variable feedback  

Energy Technology Data Exchange (ETDEWEB)

When the transmission line is very long or the generator is operated at a power factor nearly equal to 1.0, the machine regulated by an automatic voltage regulator (AVR) cannot be operated stably due to poor dynamic stability. To overcome this difficulty, the so called power system stabilizer (PSS) is very useful, in that output power or rotor speed of the generator is used as a feedback signal. The primary obective of the PSS is to damp the swing of the generator as quickly as possible. A method is proposed for designing PSS which yields a given eigenvalue. In the second method, the use of a Heffron-Phillips model is discussed. Next, a detailed procedure for the proposed design method is presented. A generalized method of a PSS design based on Park's equation and matrix operation is proposed.

1980-05-01

94

Steam generator design improvements for the candu wolsung nuclear power plant  

International Nuclear Information System (INIS)

Design considerations are given for the secondary side region of a vertical U-tube nuclear stream generator with an integral preheater. The thermal shield design, the novel recirculating water flow distribution scheme, the high porosity tube supports used in the parallel flow regions, and the U-bend supports are discussed for the Wolsung Plant steam generators. Experimental and analytical development programs undertaken to verify the design features are outlined.

1978-01-01

95

Sloshing of fluid in horizontal steam generator generated by horizontal and vertical seismic motions  

International Nuclear Information System (INIS)

The nuclear power plants with WWER type reactors are characterized by horizontally situated steam generators (SG). During seismic event the horizontal and vertical ground accelerations induce fluid motion in directions of longitudinal and transversal axis. Resulting dynamic forces act on the SG attachment and could cause the failure of screws. In obvious PSA scenarios, these phenomena are classified as a indirect induced LOCA. In this paper the effects of transversal sloshing of fluid are analyzed.

1989-08-14

96

Safety provisions for steam generator in Mochovce nuclear power plant. BO CI 04 Integrity of primary collectors of VVER 440 steam generators  

International Nuclear Information System (INIS)

This paper dealt with the identification of possible damaging mechanism of the collector of the WWER 440 steam generator, cracking of primary collectors, corrosion damage of the protective coat of the primary collector circumferential weld, cracking of breathing space in the region of blinding effect by corrosion and strain, leaking of disassembling joint of the primary collector lid and with the integrity of heat exchanging tubes.

1997-11-19

97

Reliability analysis of diesel generators of Wolsung unit 1  

Energy Technology Data Exchange (ETDEWEB)

As a maintenance optimization project to improve the safety of Wolsung NPP (Nuclear Power Plant), reliability of diesel generators are estimated based on the operating experience, and improvement options are suggested. A reliability measure is suggested for the estimation of reliability for standby safety systems to reflect availability. It is assessed that the reliability of diesel generators can be mush improved if the suggested improvement options are implemented. (Author) 6 refs., 1 tab.

1997-05-01

98

Reliability analysis of diesel generators of Wolsung Unit 1  

Energy Technology Data Exchange (ETDEWEB)

As a maintenance optimization project to improve the safety of Wolsung NPP (Nuclear Power Plant), reliability of diesel generators are estimated based on the operating experience, and improvement options are suggested. A reliability measure is suggested for the estimation of reliability for standby safety systems to reflect availability. It is assessed that the reliability of diesel generators can be much improved if the suggested improvement options are implemented.

1997-05-01

99

Direct measurements of secondary water inventory of steam generator PGV-213 in operation  

Energy Technology Data Exchange (ETDEWEB)

Results of weight measurement of PGV-213 steam generator during filling in, heating-up and power increase are described. Special measurement system based on stress gauges has been developed. Method of derivation of secondary water inventory is described. Comparison of the data for two steam generators prove accuracy of the measurements. (orig.). 1 refs.

1997-12-31

100

Causes of PGV-1000 horizontal steam generator 'cold' collector damages and ways of improving their operation reliability and service life  

International Nuclear Information System (INIS)

Specifications of the PGV-1000 steam generators applied at the WWER-1000 NPP power units, operational experience and data on damages at the 'cold' heat carriers of steam generators are considered and their results are presented. Developed and introduced measures aimed at improving reliability and operational life of the PGV-1000 collectors are described.

1993-01-01

101

Single-shaft turbine generators with 25 s"-"1 for large capacities  

International Nuclear Information System (INIS)

After explaining the main causes for the limited power output of turbine generators with 50 s"-"1, the limits for superheated-steam turbines and for saturated-steam turbines are given. A comparison of the economy in the limiting output range (1,200 MW) shows that half load plants as well as two-shaft turbine generators do not bring any advantages as compared with a single-shaft turbine generator. For the selection of speed of the single-shaft turbine generator the planned way of application is decisive. For base load plants already a speed of 25 s"-"1 is economic in this power range. Concluding, some design features and problems of development for such large turbines with 25 s"-"1 for conventional steam conditions are discussed. (orig.).

102

Incorporating externalities into a full cost approach to electric power generation life-cycle costing  

Energy Technology Data Exchange (ETDEWEB)

This study presents a full cost approach to determine the levelized cost of energy (LCOE) of 14 electricity generation technologies. It encompasses costs incurred at all stages of the fuel cycle, including those that are traditionally omitted from economic evaluations of generation technologies. Incorporating these 'externalities' increases the likelihood of developing the most economical and sustainable power resource from a societal perspective. The following externalities are included in this analysis: damage from air pollution, energy security, transmission and distribution costs, and other environmental impacts. Incorporating externalities has a large impact on the LCOE and the relative attractiveness of electricity generation options. Results indicate that clean and efficient generation technologies are the most attractive when all options are examined using ...

2002-12-01

103

Electricity supply in Germany  

Energy Technology Data Exchange (ETDEWEB)

Data on various aspects of the electric power industry in Germany is presented in this article. A map of high voltage transmission lines used by the public utilities is included, which indicates the fuel used at each power station. Data on power generated by fuel used from 1991 to 1996 is given, and additional or new capacity for 1995 to 1999 is also noted. Other tables detail capital investment in public utilities energy input by fuel source, power capacity by utility or private power stations by energy source, utility ownership and electricity demand by consumer. (UK)

1997-09-01

104

Tidd experience prepares hot gas cleaning technology for commercialization  

Energy Technology Data Exchange (ETDEWEB)

Pressurized fluidized bed combustion (PFBC) is an emerging coal-fired, combined-cycle power generation technology nearing commercial status through several operating and planned demonstration plants throughout the world. Current-generation PFBC plants use ``ruggedized`` gas turbines that can tolerate dust loading common with conventional cyclone gas cleaning. The next generation of PFBC will apply advanced hot gas cleaning systems that will reuse the dust loading to low levels acceptable to high performance, industrial gas turbines. These advances should result in performance and cost advantages. This article examines the demonstration of PFBC technology at Tidd power station.

1995-09-01

105

A horizontal steam generator for the Indian 235 MW heavy water nuclear power plants  

International Nuclear Information System (INIS)

In this paper the thermal design of a horizontal steam generator for the Indian PHWR nuclear power plant is described. The main attraction is absence of tube sheet and use of stainless steel 'U' tubes. It is emphasised that with appropriate water chemistry it is possible to use stainless steel tubes, which is many times cheaper than the Incoloy tubes used elsewhere. The design approach, applicable equation for the design and the results of computation in the form of heat transfer area and some important dimensions of the steam generator are presented.

1993-11-01

106

Power system stabilizer system having improved integrity checking scheme  

Energy Technology Data Exchange (ETDEWEB)

This patent describes improvement in a system for stabilizing the operation of an electrical generator connected to a power distribution network of the type including a power system stabilizer for providing an oscillation signal having a value which normally represents generator oscillations and a modulator circuit responsive to input signals including the oscillation signal to provide a modulated output signal for varying generator excitation, means for checking for operational integrity of the power system stabilizer. It comprises: means for applying, to the power system stabilizer, a test signal of known amplitude and frequency, the test signal simulating generator oscillations and serving to produce a simulated oscillation signal for employment as the oscillation signal, means to store representations of time related ...

1991-03-12

107

Increase in the number of distributed power generation installations in electricity distribution grids - Project findings; Zunahme der dezentralen Energieerzeugungsanlagen in elektrischen Verteilnetzen: Erkenntnisse aus dem Projekt  

Energy Technology Data Exchange (ETDEWEB)

This is the eighth part of a ten-part final report for the Swiss Federal Office of Energy (SFOE) on a project that looked into potential problems relating to the Swiss electricity distribution grid with respect to the increasing number of distributed power generation facilities being put into service. The identification of special conditions for the grid's operation and future development that take increasing decentralised power production into account are discussed. The results of the project activities encompass the analysis and evaluation of various problem areas associated with planning and management of the grid during normal operation and periods of malfunction, as well as required modifications to safety systems and grid configurations. This seventh appendix to the main report summarises and discusses the knowledge gained during the project and attempts to provide answers to various questions posed by the ...

2003-07-01

108

The effect of flue gas desulfurization availability on electric utilities. Volume II. Technical report. Final task report April--December 1977  

Science.gov (United States)

The report gives results of an analysis of the effect of the availability of a flue gas desulfurization system on the ability of an individual power plant to generate electricity at its rated capacity. (The availability of anything is the fraction of time it is capable of service, whether or not it is actually in service.) Also analyzed are its effects on a power generating system (a group of several coal-, oil-, and gas- fired power plants plus nuclear and hydroelectric plants).

1978-03-01

109

Performance before and after installation of a Power System Stabilizer (PSS). Gedrag voor en na toevoeging PSS  

Energy Technology Data Exchange (ETDEWEB)

The damping of unwanted oscillations in the generator units after a failure can be realized by installing a stabilizer between f.e. the revs of the generator and an input of the voltage regulator. The tuning of a Power System Stabilizer (PSS) is investigated using bode plots. Eigenvalue analysis shows an enlarged system stability margin. The method was tested on an advanced analogue power system simulator. As a result of these tests it appears to be useful to consider the stability as well as the optimal tuning. 5 figs., 6 refs.

1992-10-01

110

Research and development of photovoltaic power system; Taiyoko hatsuden system no jissho kenkyu  

Energy Technology Data Exchange (ETDEWEB)

This paper reports the result obtained during fiscal 1994 on a demonstration research on photovoltaic power generating systems. Solar cells with an output of 750 kW, storage battery facilities with an output of 3,058 kWh, three DC-AC converters with a rating of 250 kW, and a diesel generator with an output of 300 kW having been installed up to the previous fiscal year were combined to perform comprehensive adjustments and tests such as battery charge/discharge tests and AC parallel operation tests. The battery charge/discharge tests revealed that the 10 hour rate discharge capacity meets the specifications, and the batteries are free of deterioration after a demonstration operation of about 4.5 months. Difference between the power generation record and the planned value is thought due to the following reasons: the array output data in a power line connected ...

1994-12-01

111

The determination of the tuning of a Power System Stabilizer (PSS). De bepaling van de instelling van een Power System Stabilizer  

Energy Technology Data Exchange (ETDEWEB)

By means of an analogous simulator, which can simulate a power supply system, a method to determine the transfer function of a Power System Stabilizer (PSS) is developed. The purpose of the PSS is to damp unwanted electro-mechanical oscillations. The method is very systematic and there is no need for specified values of the parameters used in the system. It is assumed that the power generator system is linear for small variations. The system can be considered to be a black box. Measurements executed by means of this method are completely controlled by the person who enforces the measurement. By applying this method carefully, irregularities are almost out of the question. The equipment necessary are a PC with two AD-ports and an adjustable sinus-generator. A comparison is made with a more traditional method, in which a spectrum analyzer is used. 4 figs., 7 refs.

1992-10-01

112

Adaptive power-system stabilizer based on turbine governor control  

Energy Technology Data Exchange (ETDEWEB)

A novel adaptive stabilizer, called an Adaptive Governor Power System Stabilizer (AGPSS), which operated on the governor turbine system, was described. There has been extensive research on adaptive excitation control of generators in power systems with the goal of achieving better dynamic performance. AGPSS tracks the frequency and damping of oscillations in a power system, and adjusts to ensure that there is always sufficient damping in the system. There is no interaction between stabilizers on different generating units, and each one acts independently, consuming oscillation energy locally. These stabilizers are easy to design and this facilitates their use in multimachine systems. Results obtained by nonlinear simulation of a single-machine and a three-machine power system were discussed, illustrating the effectiveness of the stabilizers in supplying damping ...

1994-12-31

113

Developing, financing and managing merchant (independent) power plants  

Energy Technology Data Exchange (ETDEWEB)

Deregulation and restructuring changes in the electric power industry have provided opportunities to build new power plants. These power plants, however, will not enjoy long-term power purchase agreements with the utilities they serve, but will have to respond to the market. This is where the term `merchant plant` originates. Calpine Corp. presented its reasons for believing that now is the best time to be building new merchant plants based on modern natural gas-fired, combined-cycle power plants. Among those reasons are: (1) construction of new nuclear power plants has been rejected by people on both sides of the border, (2) attempts to promote alternative energy sources such as solar, wind and biomass have not added significant generation capacity and are not likely to do so in the near future because of their high cost, and (3) coal-fired ...

1998-08-01

114

Implementation and laboratory test results for a fuzzy logic based self-tuned power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the implementations of a fuzzy logic based self-tuned controller to improve the stability of electric power systems. The stabilizing signal is computed using the standard fuzzy membership function depending on the speed/acceleration state of the generator in the phase plane. The performance of the proposed stabilizer is demonstrated by practical implementation using a digital signal processor mounted on a PC-AT. Results of the experimental tests on a physical model of a power system are presented.

1993-06-01

115

High-temperature superconductivity (HTS): summary of case study results; Vorteile der Hochtemperatursupraleitung. Resultate von Fallstudie  

Energy Technology Data Exchange (ETDEWEB)

The system study 'High Temperature Superconductivity (HTS) in power systems' lists the technical and economical advantages for power generation, transmission and distribution systems using components made of HTS material as seen in the light of current knowledge in the superconductivity area. This report lists the advantages of using high-temperature superconductivity in the power industry area and summarises the results obtained in various case studies on the subject.

2000-07-01

116

Guide to UK renewable energy companies 2001. 6. ed.  

International Nuclear Information System (INIS)

This 2001 edition of the guide to UK renewable companies and equipment and service providers presents summaries of the different industry sectors covering wind power, photovoltaics, solar water heating, geothermal heat pump, hydroelectric power, marine current and wave technology, bioenergy, power generation from landfill gas, energy from waste, and cogeneration. A UK company classification listing and index is provided along with listing of UK organisations and companies and an index of advertisers.

117

A new control strategy for tracking peak power in a wind or wave energy system  

Energy Technology Data Exchange (ETDEWEB)

This paper proposes a novel control strategy for tracking peak power in a wind or wave energy system using a squirrel cage induction generator. It eliminates wind speed measurement or estimation and uses a simple scalar technique by exploiting the cubic nature of the power curve. The method works even when air velocity is varying dynamically. (author)

2009-06-15

118

A Study on the Matching between the Straight Wing Non-articulated Vertical Axis Wind Turbine and the New Wind Turbine Generator  

Science.gov (United States)

In the current wind turbine generation system, there are substantial problems such as the maximum power of the wind turbine cannot be obtained under the fluctuating wind speed, high in cost and low in annual net electricity production (due to mismatch between a generator and a wind turbine). A new wind turbine generator optimized for the wind turbine output is presented in order to solve such problems. This wind turbine generator consists of a permanent magnet generator, a reactor and a rectifier, and uses neither a control circuit which requires standby electricity nor a PWM converter having a switching element. By selecting most appropriate combination of the permanent magnet generator having multiple windings and the reactor connected in series with each winding, the maximum output of the wind turbine can be obtained without using a ...

2008-01-01

119

Substantiation of recommendations for ensuring the design service life of heat-transfer tubes used in a PGV-1000MKP steam generator  

Science.gov (United States)

We present the results obtained from tests and studies carried out on the model of tube bundles for a PGV-1000 horizontal steam generator that were conducted for experimentally substantiating the design service life of a steam generator tube bundle intended for use at new nuclear power stations equipped with a PGV-1000MKP steam generator. Measures taken to minimize the incipience and development of local corrosion damage to the heat-transfer tubes and ensure their design service life are substantiated and confirmed.

2011-03-01

120

Wind power in China-Opportunity goes with challenge  

British Library Electronic Table of Contents (United Kingdom)

Climate change and limited primary energy resources require indigenous renewable electricity generation options to change the current coal-dominated power source matrix in China. The wind power is such a solution for the above challenges, and it still has large space for improvement in China. In this paper several critical factors related to Chinese wind power were studied in details, including the wind resources, the wind turbine industry and the policies from the Chinese government. Based on the study, the perspective of wind power in China was discussed. With outstanding advantages, the offshore wind power has a bright future in China, so its main characteristics are discussed. Based on the discussions, suggestions were given to improve the development of Chinese wind power, and the gov...

2010-01-01

121

Wind power in China - Opportunity goes with challenge  

Energy Technology Data Exchange (ETDEWEB)

Climate change and limited primary energy resources require indigenous renewable electricity generation options to change the current coal-dominated power source matrix in China. The wind power is such a solution for the above challenges, and it still has large space for improvement in China. In this paper several critical factors related to Chinese wind power were studied in details, including the wind resources, the wind turbine industry and the policies from the Chinese government. Based on the study, the perspective of wind power in China was discussed. With outstanding advantages, the offshore wind power has a bright future in China, so its main characteristics are discussed. Based on the discussions, suggestions were given to improve the development of Chinese wind power, and the government's further measures are also ...

2010-10-15

122

Coordinated synthesis of multimachine power system stabilizer using an efficient decentralized modal control (DMC) algorithm  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a new method for simultaneously selecting the power system stabilizer (PSS) parameters in multimachine power systems. Design of local output feedback power system stabilizer using local signal of the generator (e.g. speed or power) is formulated as a decentralized modal control (DMC) problem. Exact model reduction based on modal control theory is proposed to make the determination of PSS parameters highly efficient. Results obtained from the coordinated tuning of the parameters of three power system stabilizers equipped on a multimachine power system show that exact assignment of the eigenvalues associated with the poorly damped electromechanical modes can be achieved in a very efficient manner.

1986-01-01

123

12th Symposium on Space Nuclear Power and Propulsion. Conference on Alternative Power from Space (APFS),Conference on Accelerator-Driven Transmutation Technologies and Applications (A-DTTA)  

International Nuclear Information System (INIS)

These proceedings represent papers presented at the 12th symposium on Space Nuclear Power and Propulsion held in Albuquerque, New Mexico. The symposium theme was ''commercialization and technology transfer''. The topics discussed include: wireless power transmission, solar power from space next generation spacecraft, space power electronics and power management, flight testing of components, manufacturing and processing of materials, nuclear propulsion, reactors and shielding and many others of interest to the scientific community representing industry, government and academic institutions. There were 163 papers presented at the conference and 60 have been abstracted for the Energy Science and Technology database.

1995-01-08

124

Small, efficient thermophotovoltaic power supply. Final report, 21 February 1997--21 February 1999  

Energy Technology Data Exchange (ETDEWEB)

The objective of this contract is to design and build a small, lightweight, stand-alone thermophotovoltaic electric generator, capable of at least 100 Watts useful output for charging 24V batteries. The prototype generator built consists of a pre-mixed burner, a cylindrical selective emitter mantle surrounded by six silicon photovoltaic concentrator arrays. The arrays are cooled with forced-air heat exchangers using self-powered fans. The generator, operated at 117,00 W (40,000 BTU/hr) of fuel input rate, produces 122 W of electrical power at 1.0% of efficiency. The cooling and pre-mix fans consume 35 W of electrical power resulting in a net 85 Watts of electrical output for charging batteries. The generator`s output is capable of continuous charging five 12/24V batteries over 10 hours with a 9.07 Kg (20 lbs.) of propane gas.

1999-04-23

125

Short term hydroelectric power system scheduling with wind turbine generators using the multi-pass iteration particle swarm optimization approach  

Energy Technology Data Exchange (ETDEWEB)

This paper uses multi-pass iteration particle swarm optimization (MIPSO) to solve short term hydroelectric generation scheduling of a power system with wind turbine generators. MIPSO is a new algorithm for solving nonlinear optimal scheduling problems. A new index called iteration best (IB) is incorporated into particle swarm optimization (PSO) to improve solution quality. The concept of multi-pass dynamic programming is applied to modify PSO further and improve computation efficiency. The feasible operational regions of the hydro units and pumped storage plants over the whole scheduling time range must be determined before applying MIPSO to the problem. Wind turbine power generation then shaves the power system load curves. Next, MIPSO calculates hydroelectric generation scheduling. It begins with a coarse time stage and searching space and ...

2008-04-15

126

Re-potentiation of hydro-generators: a proposal of analysis and implementation methodology; Repotenciacao de hidrogeradores: uma proposta de metodologia de analise e implantacao  

Energy Technology Data Exchange (ETDEWEB)

The hydro-generators suffer during its operative useful life a combination of stresses of nature thermal, electric, mechanics and environmental. With the time, they are going losing the capacity to support those stresses and the power plants suffer, more and more frequently, undesirable stops for repair services and maintenance. In function of the high costs incurred with these stopped, the operation of the power plant can be economically impracticable. That unavailability of the generation for the electric system, it results in reduction of the reliability, burdening the politics of load ruling. The re-potentiation is a proposal that seeks to extend the useful life of hydro-generators, at the same time that it try to rescue the reliability and the readiness of the plant, with larger power. The power increase is usually made possible, or for ...

1996-07-01

127

Research and development of peripheral technology for photovoltaic power systems. Meteorological analysis for suitable design of photovoltaic power generation systems; Shuhen gijutsu no kenkyu kaihatsu. Saiteki sekkei no tame no kisho data no chosa kenkyu  

Energy Technology Data Exchange (ETDEWEB)

This paper reports the study results on the standard weather data necessary for simulation of PV power generation systems in fiscal 1994. In the study on the selection criterion of the standard weather data from the viewpoint of PV power generation systems, three typical years are used; a year with average solar radiation, and two years with extremely less and more solar radiation for safe simulation. The standard weather data are arranged for output calculation of PV power generation systems by selecting the most typical year based on long-term observation data. The data to be arranged are as follows; total, direct and scattered solar radiations incident upon a horizontal surface, solar radiation upon a slope surface, sunshine duration, air temperature, wind direction, wind velocity, amount of precipitation, and snow depth. For arrangement of the nationwide ...

1994-12-01

128

Conference on reformation of regulation in OECD/IEA power sector - Conference on reformation of regulation in USA, Netherlands, Japan  

Energy Technology Data Exchange (ETDEWEB)

Since 1995, OECD started to examine the current situation of government regulation in each member country and discussed to recommend quality improvement of regulation to member countries. The conference on reformation of regulation in power industry was held in October and December 1998. In USA, enhancing competition in supplying electricity was recommended by eliminating differentiation in use of power network, transmission network and incidental facilities. The retail competition is also an important reformation. The reformation in Netherlands can be seen as following EU guide for revealing problems of the existing regulation in the power industry and for opening up a power market. The Dutch government passed the power act for opening up a market to the public between 1999 and 2007. In Japan, the entry of independent power provider (IPP) has been softened. ...

1999-01-01

129

Outlook for using wind energy for electrification of agriculture in Estonian SSR  

Energy Technology Data Exchange (ETDEWEB)

The developed electrical networks in the agricultural regions of the Estonian SSR make it possible to construct relatively powerful wind power plants at the sites of the most favorable wind conditions with small outlays for the power transmission lines. The wind power plant electricity can be used to electrify the production processes in agriculture, while the surplus can be supplied to the energy system. The inclusion of the wind power plants in the energy system makes it possible to improve the total generation of energy or reduce the consumption of fuel. With the efficient arrangement of the wind power plants, one can also reduce the energy losses during its transfer. Calculations indicated that in the coastal zones of the Estonian SSR, one can obtain specific power of 420-480 kW/km/sup 2/. For comparison it is ...

1982-01-01

130

Impact of independent power producers in a deregulated system  

Energy Technology Data Exchange (ETDEWEB)

Independent power producers (IPPs) have had open access to existing power systems ever since the electric power industry was restructured and deregulated. IPPs are small-scale, distributed, and independently operated. Introducing an IPP to the power system can be beneficial to the existing power system because it can increase the security margin or reduce production cost and environmental pollution. The disadvantage is that some IPPs are not subject to dispatch control, consequently, they may reduce the network security. Often IPPs use co-generation, small-scale hydro, even fuel cells or other types of renewable energy sources. An evaluation of IPPs impact on an existing utility power system was determined in a modified IEEE 14 bus system. The total generating cost, environmental impact, transmission line margin, voltage ...

1997-04-01

131

Analysis of even harmonics generation in an isolated electric power system  

British Library Electronic Table of Contents (United Kingdom)

Harmonics bred from loads are mainly odd order because the current waveforms have half-wave symmetry. Since the even harmonics are negligibly small, they generally are not measured in electric power systems. However, even harmonics were measured at a 500/275/154 kV substation in Hokuriku Electric Power Company after a transmission line fault was corrected. The even harmonics caused malfunctions of protective digital relays because the relays used 4th harmonics at the input filter as the automatic supervisory signal. This paper describes mechanisms of generation of the even harmonics by comparing the measured waveforms with the ATP-EMTP simulation results. Analysis of these results has clearly shown that there are three different mechanisms of generation of even harmonics. The first mechani...

2009-01-01

132

An adaptive synchronous generator stabilizer design by generalized multivariable pole shifting (GMPS) technique  

Energy Technology Data Exchange (ETDEWEB)

A robust adaptive Power System Stabilizer algorithm using a Generalized Multivariable Pole Shifting (GMPS) technique is presented in this paper. The algorithm handles systems with equal or unequal numbers of inputs and outputs, therefore both shaft speed as well as the generator power are used to derive the stabilizing control. The technique also provides a simple scheme of on-line self-searching pole shifting factor to meet the excitation control limits. The application of the proposed stabilizer to a simulated generator excitation control under a wide range of operating and disturbance conditions demonstrates that the new control strategy is superior to conventional Power System Stabilizer (PSS) and the widely accepted Minimum Variance Self-Tuning Controller (MVSTC).

1992-08-01

133

Unconventional systems for lunar base power generation and storage  

International Nuclear Information System (INIS)

Recent advances in thin film solar photovoltaic converters (PV's) can furnish multimegawatt power levels during lunar daylight periods with only modest mass requirements. The extended duration of lunar night (ca. 354 hr) and the high specific mass of earth-imported energy storage systems (regenerative fuel cells, batteries, etc.) render PV plus import storage power systems non-competitive with nuclear power plants for lunar bases. However, power storage or generation methods which can be constructed using primarily lunar materials, used either alone or with lightweight PV's, can be attractive alternatives to nuclear power. Three separate generic systems which can provide favorable low import mass goals have been identified and studied. These are: gravitational energy generation using lunar soil, thermal energy storage using basalt rock or ...

1990-08-12

134

IEA Greenhouse Gas R and D Programme annual report 1998  

Energy Technology Data Exchange (ETDEWEB)

The report outlines the role of the IEA Greenhouse Gas R and D Programme, gives details of participants and of publications and summarises achievements of 1998. A successful conference on Greenhouse Gas Control Technologies was held in Interlaken, Switzerland. Technical studies reported include novel power generation concepts for removing carbon dioxide prior to or after combustion, using seawater for CO{sub 2} capture, investigating carbon dioxide sequestration in conjunction with enhanced coalbed methane recovery and applying retrofitting to power plants and to offshore oil and gas platforms. Systems studies taking a broader view include investigating the potential for combined energy systems (power generation with district heating, power with district cooling etc.) to reduce CO{sub 2} abatement cost, studies on the LNG/power ...

1999-07-01

135

Design of a nonlinear power system stabilizer using synergetic control theory  

Energy Technology Data Exchange (ETDEWEB)

Electromechanical oscillations of small magnitude and low frequency exist in the interconnected power system and often persist for long periods of time. Power system stabilizers (PSSs) are traditionally used to provide damping torque for the synchronous generators to suppress the oscillations by generating supplementary control signals for the generator excitation system. Numerous techniques have previously been proposed to design PSSs but many of them are synthesized based on a linearized model. This paper presents a nonlinear power system stabilizer based on synergetic control theory. Synergetic synthesis of the PSS is based fully on a simplified nonlinear model of the power system. The dynamic characteristics of the proposed PSS are studied in a typical single-machine infinite-bus power system and compared with the ...

2009-06-15

136

Variable-speed generation enhances hydro operation  

Energy Technology Data Exchange (ETDEWEB)

Two major developments have given impetus to wider adoption of variable-speed turbine/generators in hydroelectric plants, both essentially environmental: (1) the need for stream-bed stability below river dams, and (2) the need to minimize fish damage. Also, the need to stabilize pumped-storage and generating efficiencies to match extreme changes in head levels has been a driving force. Variable-speed operation in hydro applications is relatively new to North America. In other parts of the world, it has been used in pumped-storage plants since 1971. In the US, and increasing potential exists for variable-speed hydro, considering the 30 pumped-storage plants already in operation and several river plants struggling with high head fluctuations--including four at stations operated by the Bonneville Power Administration. Several modifications to hydro-plant hardware and operating procedures are actively being considered at ...

1993-07-01

137

Thermophotovoltaics. Basic principles and critical aspects of system design  

Energy Technology Data Exchange (ETDEWEB)

Thermophotovoltaics is the science and technology associated with the direct generation of electricity from high temperature heat. Potential applications include combined heat and power, portable and auxiliary power, radioisotope space power, industrial waste heat recovery and concentrated solar power. This book aims at serving as an introduction to the underlying theory, overview of present day components and system arrangements, and update of the latest developments in the field. The emphasis is placed on the understanding of the critical aspects of efficient thermophotovoltaic system design. The aim is to assist researchers in the field. (orig.)

2011-07-01

138

Safety review of conceptual fusion power plants  

Science.gov (United States)

The potential public safety impacts from accidents in conceptual fusion power plants were investigated. Fusion was found to have some potential for accidents, as does any energy generating system. Functions of fusion power plants were identified that possess sufficient potential for an accidental release of toxic materials to the environment. An assessment was made of the impact of the potential accidents and recommendations are included for R and D that will allow incorporation of safety concerns in fusion power plant design. This work was based on a review of information available in conceptual design documents of fusion reactor systems.

1976-11-01

139

Safety review of conceptual fusion power plants  

International Nuclear Information System (INIS)

The potential public safety impacts from accidents in conceptual fusion power plants were investigated. Fusion was found to have some potential for accidents, as does any energy generating system. Functions of fusion power plants were identified that possess sufficient potential for an accidental release of toxic materials to the environment. An assessment was made of the impact of the potential accidents and recommendations are included for R and D that will allow incorporation of safety concerns in fusion power plant design. This work was based on a review of information available in conceptual design documents of fusion reactor systems.

140

Digital AVR application to power plants  

Energy Technology Data Exchange (ETDEWEB)

The digital AVR must have the level of redundancy and control functions that conform to the configuration of the excitation control system and to the importance of a particular generator for the user. The digital AVR is not simply a digital version of the analog AVR, but can realize sophisticated control functions that were difficult to achieve with analog circuits, thus making it possible to enhance the stability of power system by PSS (power system stabilizer). This paper describes the test results of the digital AVRs applied to power plants, their system configuration and functions, as well as the outline of an auto-tuning PSS or AT-PSS planned to be incorporated in the digital AVR in the future.

1993-12-01

141

Design of self-tuning PID power system stabilizer for multimachine power systems  

Energy Technology Data Exchange (ETDEWEB)

A self-tuning PID (proportional-integral-derivative) power system stabilizer (PSS) is presented for improving the dynamic stability of a multimachine power system over a wide range of operating conditions. In order to maintain good damping characteristic when there is a drastic change in system operating condition, the gain settings are adapted in real time based on the continuously measured system inputs and outputs. The proposed self-tuning stabilizer has a decentralized structure and only local measurements within each generating units are required for the adaptation process. The effectiveness of the proposed stabilizer is demonstrated by an example.

1988-08-01

142

Corrosion and reliability of PWR power plants  

International Nuclear Information System (INIS)

Corrosion is increasingly becoming an important factor reducing the reliability of many nuclear power plant components. The significance is evaluated of corrosion phenomena with respect to the reliability of primary circuit components of LWR's, viz., the reactor pressure vessel, primary piping, steam generator, and fuel elements. The mechanism of corrosion phenomena is explained and methods of minimizing their effects are presented. An analysis is made of the needs to solve the corrosion problems of nuclear power plants from the point of view of Czechoslovak producers and research and development activities. International cooperation is reviewed and main problems are formulated on which the solution of corrosion problems of structural materials used in WWER type nuclear power plants should be focussed. (author).

143

Challenges of efficient and clean use of fossil fuels for power production  

Energy Technology Data Exchange (ETDEWEB)

Constantly increasing resource efficiency together with the broad introduction of CCS technologies is fundamental for a continuous use of fossil fuels in power generation against the background of up-coming requirements for CO2 emission reduction. In principle, CCS means up-grading conventional power plant technology with proven CO2 removal processes. However, this leads to additional losses, auxiliary power demand and cost. System integration, development or at least adaption of components and processes are the main requirements in this context. Different technology solutions and recent developments will be addressed as well as challenges when implementing in demonstration projects.

2010-09-15

144

Adaptive conventional power system stabilizer based on artificial neural network  

Energy Technology Data Exchange (ETDEWEB)

This paper deals with an artificial neural network (ANN) based adaptive conventional power system stabilizer (PSS). The ANN comprises an input layer, a hidden layer and an output layer. The input vector to the ANN comprises real power (P) and reactive power (Q), while the output vector comprises optimum PSS parameters. A systematic approach for generating training set covering wide range of operating conditions, is presented. The ANN has been trained using back-propagation training algorithm. Investigations reveal that the dynamic performance of ANN based adaptive conventional PSS is quite insensitive to wide variations in loading conditions.

1995-12-31

145

Materials choices for the advanced LWR steam generators  

International Nuclear Information System (INIS)

Current light water reactor (LWR) steam generators have been affected by a variety of corrosion and mechanical damage degradation mechanisms. Included are wear caused by tube vibration, intergranular corrosion, pitting, and thinning or wastage of the steam generator tubing and accelerated corrosion of carbon steel supports (denting). The Electric Power Research Institute (EPRI) and the Steam Generator Owners Groups (I, II) have sponsored laboratory and field studies to provide ameliorative actions for the majority of the damage forms experienced to date. Some of the current corrosion mechanisms are aggravated or caused by unique materials choices or materials interactions. New materials have been proposed and at least partially qualified for use in replacement model steam generators, including an advanced LWR design. In so far as possible, the materials choices for the advanced LWR ...

1987-11-15

146

Analysis of thermal hydraulics and soluble impurity distribution in horizontal steam generator PGV-1000 with STEG code  

International Nuclear Information System (INIS)

The 3D modeling of the thermal hydraulic processes and soluble impurity distribution in the horizontal steam generator PGV-1000 was fulfilled with the thermal hydraulic code STEG. Steady-state operation of horizontal seam generator PGV-1000 was analyzed at nominal power. The modeling of the soluble impurity distribution was fulfilled on the basis of the previous thermal hydraulic modeling results. The processes of the soluble impurity deposition on the steam generator tube bundles and deposits outwash were considered in the mathematical model of the code. The modeling was fulfilled for horizontal steam generators with different peculiarities in construction. Calculation results were compared with experimental results obtained at NPP. The agreement between calculated and experimental results is quite reasonable. Results of modeling are sensible to the peculiarities of the horizontal ...

2003-04-20

147

The efficiency of coal-fired combined-cycle powerplants  

Energy Technology Data Exchange (ETDEWEB)

Concepts involving combined gas-turbine/steam-turbine power-generation plants, in which the fuel gas for the gas turbine is produced via the gasification of coal, are now extremely advanced. This technology already permits efficiencies of around 50% current development targets view 65% as achievable. In conventional technology, efficiencies are tied to conditions, such as air and cooling-water temperatures, at the particular location. In combined-cycle power plants, the properties of the fuel coal also play an important part. There are, in face, coals which can be more advantageously used in a combined-cycle power plant than in a conventional one. These differences, combined with advantageous concepts for coal-fired combined-cycle power-generating plants, are presented and analyzed. Particular attention is devoted to individual losses occurring at coal conversion, thermodynamic cycles, integration of ...

1996-12-01

148

Simulation of the New York Power Pool for dispatcher training  

Science.gov (United States)

This paper describes the simulation of the operating environment of the New York Power Pool (NYPP) within the Dispatcher Training Simulator facility at the New York State Electric and Gas Corporation (NYSEG). The NYSEG control center uses real-time data received from the NYPP control center to control its internal generation. In addition, the NYSEG dispatchers work very closely with the NYPP dispatchers. The exact emulation of the Generation Control functions of the NYPP EMS, and the associated data exchange with the NYSEG ECS, contribute greatly to the high degree of realism achieved in the NYSEG DTS facility. The accuracy of the power system simulation in the DTS has been validated against actual power system disturbances recorded at NYSEG.

1994-11-01

149

Report on definitional mission: Hungary gas-fired power plants. Export trade information  

Energy Technology Data Exchange (ETDEWEB)

The U.S. Trade and Development Program (TDP) had received a request from the Hungarian Electricity Board (MVMT) for assistance in support of a feasibility study program to: (1) install new generation capability based on gas/oil fired combined cycle power plants, and (2) retrofit/refurbish a number of aging coal and oil fired steam plants. A Definitional Mission (DM) recommends that TDP fund the requested feasibility studies for new gas/oil fired combined cycle capabilities discussed in the Terms of Reference (TOR). Hungary will need to install significant new power capacity between now and the end of the century. Gas/oil fired combined cycle plants present probably the only option to install capacity rapidly. There is an opportunity for U.S. firms to supply technology and services with respect to these advanced power generation technologies.

1991-02-28

150

High efficiency by advanced power plant engineering. Siemens PG: Best solutions for high-tech steam turbines; Hoehere Wirkungsgrade durch moderne Kraftwerkstechnik. Siemens PG: Best solutions fuer High-tech-Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

A consequent use of computers and standardized components enables high efficiency for steam turbines while produced at lower manufacturing cost as shown here in the Muehlheim company of Siemens Power Generation, where steam turbines are produced for new stations and retrofitted elder power plants. [German] Auch eine ueber hundert Jahre alte Technik bietet Raum fuer Innovationen: Konsequenter Computereinsatz und standardisierte Baureihen ermoeglichen bei Dampfturbinen hohe Wirkungsgrade bei relativ niedrigen Fertigungskosten - umgesetzt im Werk Muelheim der Siemens Power Generation, wo Dampfturbinen fuer Neuanlagen und zum Modernisieren bestehender Kraftwerke entstehen. (orig.)

2002-07-01

151

A Maximum Power Point Tracking Control Method of a Photovoltaic Power Generator with Consideration of Dynamic Characteristics of Solar Cells  

Science.gov (United States)

This paper discusses a new control strategy for photovoltaic power generation systems with consideration of dynamic characteristics of the photovoltaic cells. The controller estimates internal currents of an equivalent circuit for the cells. This estimated, or the virtual current and the actual voltage of the cells are fed to a conventional Maximum-Power-Point-Tracking (MPPT) controller. Consequently, this MPPT controller still tracks the optimum point even though it is so designed that the seeking speed of the operating point is extremely high. This system may suit for applications, which are installed in rapidly changeable insolation and temperature-conditions e.g. automobiles, trains, and airplanes. The proposed method is verified by experiment with a combination of this estimating function and the modified Boehringer's MPPT algorithm.

2004-01-01

152

3D modelling as a support to thermal-hydraulic safety analyses with standard codes  

Energy Technology Data Exchange (ETDEWEB)

A three-dimensional (3D) thermal-hydraulic model and a numerical procedure for the simulation and analysis of a steady-state, as well as transient operation of nuclear power plant components are presented. A two-fluid approach is applied to modelling of two-phase flow. Thermal-hydraulics of a horizontal steam generator in the WWER 1000 nuclear power plant has been simulated at the full load, steady-state operation. A comparison of the numerical results with data measured at the NPP Novovoronjezh shows good agreement. 3D numerical results can be used in plant design or retrofitting, in nuclear power plant operation and safety analysis and as improvement of existing one-dimensional thermal-hydraulics models of the horizontal steam generator which are assessed by system codes used for the nuclear power plant safety analyses. (author)

1999-07-01

153

3D modelling as a support to thermal-hydraulic safety analyses with standard codes  

International Nuclear Information System (INIS)

A three-dimensional (3D) thermal-hydraulic model and a numerical procedure for the simulation and analysis of a steady-state, as well as transient operation of nuclear power plant components are presented. A two-fluid approach is applied to modelling of two-phase flow. Thermal-hydraulics of a horizontal steam generator in the WWER 1000 nuclear power plant has been simulated at the full load, steady-state operation. A comparison of the numerical results with data measured at the NPP Novovoronjezh shows good agreement. 3D numerical results can be used in plant design or retrofitting, in nuclear power plant operation and safety analysis and as improvement of existing one-dimensional thermal-hydraulics models of the horizontal steam generator which are assessed by system codes used for the nuclear power plant safety analyses. (author)

1999-04-19

154

Alteration in reactor installation (addition of Unit 2) in the Sendai Nuclear Power Station of Kyushu Electric Power Co., Inc  

International Nuclear Information System (INIS)

The deliveration by the Nuclear Safety Commission was commenced on the alteration in reactor installation, as it had been inquired by the Ministry of International Trade and Industry. The alteration is the additional installation of the reactor No. 2 in the Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc. It is a PWR power plant with thermal output of about 2,660 MW (electric output of 890 MW), to be installed, adjoining to the reactor No. 1 of the same type and capacity under construction. In the examination by MITI, it was confirmed that the technological capabilities for its construction and operation and the radiation protection measures in power generation are both sufficient. The contents of the examination include the siting conditions, the location and construction of reactor facilities, etc. (J.P.N.).

1980-01-01

155

Alteration in reactor installation (addition of Unit 2) in the Sendai Nuclear Power Station of Kyushu Electric Power Co. , Inc  

Energy Technology Data Exchange (ETDEWEB)

The deliberation by the Nuclear Safety Commission was initiated on the alteration in reactor installation, as was required by the Ministry of International Trade and Industry. The alteration is the additional installation of the reactor No. 2 in the Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc. It is a PWR power plant with thermal output of about 2,660 MW (electric output of 890 MW), to be installed, adjoining to the reactor No. 1 of the same type and capacity under construction. In the examination by MITI, it was confirmed that the technological capabilities for its construction and operation and the radiation protection measures in power generation are both sufficient. The contents of the examination include the siting conditions, the location and construction of reactor facilities, etc.

1980-10-01

156

Volume 2- Technical Approach - IMAGE Science Center - NASA  

Science.gov (United States)

Power system analysis shows the output from the solar arrays varies as a function .... Each array corresponds to a raw image browse product, which is generated by .... low outgassing, ability to withstand long-term exposure to the space ...

157

Theory of multifoil collision supercompression  

Energy Technology Data Exchange (ETDEWEB)

Investigations of superdense compression touch on such problems as ultrahigh-frequency oscillations of matter in the generation of gravitational waves, the powerful pumping of hard coherent radiation, and the laboratory simulation of stellar interiors. This paper reviews the theory of supercompression and discusses some experiments involving multifoil collision supercompression.

1980-01-01

158

Study on the transient piping vibration of power plant. Secondary piping system of Wolsung 1 unit.  

Science.gov (United States)

In order to maintain a safe operation and availability of generating facilities, qualitative and quantitative assessment of piping vibration was performed vibration sources and damages of piping support was identified on the second piping system of Wolsun...

1996-01-01

159

Steam turbines for cogeneration plants; Dampfturbinen fuer die Kraft-Waerme-Kopplung  

Energy Technology Data Exchange (ETDEWEB)

The demand for cogeneration plants is growing worldwide. For the combination of electricity generation and heat extraction in power stations facilitates an excellent fuel exploitation and makes the operator of the plant independent from external energy suppliers. (orig.)

2006-07-01

160

Recent uses of robotics for remote inspection and maintenance  

International Nuclear Information System (INIS)

This paper documents some of the recent uses of robotics for inspection and maintenance activities in Ontario Hydro's nuclear power plants in areas other than fuel channels and steam generators. 7 figs.

1992-11-22

161

Maximum capacity of steam turbine units  

International Nuclear Information System (INIS)

The author investigates the question of the maximum capacity of steam turbines in nuclear power plants when towards the end of the nineties turbo-generator units of 3,000 MW and more will be necessary as a result of increased energy demand. (TK).

162

Magnetic mirror fusion systems: Characteristics and distinctive features  

Energy Technology Data Exchange (ETDEWEB)

A tutorial account is given of the main characteristics and distinctive features of conceptual magnetic fusion systems employing the magnetic mirror principle. These features are related to the potential advantages that mirror-based fusion systems may exhibit for the generation of economic fusion power.

1987-08-10

163

IMO Momentenlager GmbH: Reliable ball bearings made in Middle Franconia; IMO Momentenlager GmbH: Zuverlaessige Kugellager aus Mittelfranken  

Energy Technology Data Exchange (ETDEWEB)

IMO Momentenlager GmbH of Gremsdorf near Nuremberg produces large rotary bearings for ENERCON wind power systems, preferably for the E-70 and E-82 generators. (orig.)

2007-07-01

164

Heat Cycle Reserch Experimental Program report, FY-84  

Energy Technology Data Exchange (ETDEWEB)

The Heat Cycle Research Facility (HCRF) is an experimental binary-cycle facility used to investigate different concepts and/or components for generating electrical power from a geothermal resource. This report briefly desc

1984-09-01

165

Harnessing the geothermal resources of sedimentary basins for electricity production  

Science.gov (United States)

Use of geothermal resources for generating electricity is briefly analyzed. Results obtained from optimization of the thermodynamic cycle implemented in the secondary coolant circuit of a binary geothermal power station and the parameters of its primary heat carrier circuit are presented.

2011-02-01

166

Formation and fate of gaseous and particulate mutagens and carcinogens in real and simulated atmospheres.  

UK PubMed Central (United Kingdom)

The growing use of coal for heating and electric power generation and diesel engines in light duty motor vehicles will increase not only the existing atmospheric concentrations of criteria pollutants...Full Text Available

1983-01-01

167

Electric power monthly, July 1995 - with data for April 1995  

Energy Technology Data Exchange (ETDEWEB)

This publication provides statistical data on net generation, fuel consumption, fossil fuel stocks, electricity sales, revenue, and average revenue per kilowatthour of electricity sold. Data on fossil fuel stocks and costs are also included.

1995-07-01

168

Atomic-scale insight and design principles for turbine engine thermal barrier coatings from theory  

UK PubMed Central (United Kingdom)

To maximize energy efficiency, gas turbine engines used in airplanes and for power generation operate at very high temperatures, even above the melting point of the metal alloys from which they are...Full Text Available

2011-04-05

169

Power system stabilizer application in a two unit plant analytical studies and field tests  

Energy Technology Data Exchange (ETDEWEB)

The use of excitation system controls, specifically the Power System Stabilizer (PSS), to improve damping of power system oscillations and thus extend steady-state stability limits has been a subject of great interest in recent years. The desire to more fully utilize transmission capacity led to the installation of PSS controls on greater numbers of generating units to maintain stability margins. This paper addresses the tuning and adjustment of PSS controls in a two unit power plant. Both analytical studies and field test confirmations are presented. The practical difficulties of verifying the PSS control loop gain margin by testing are explored. A simplified procedure is outlined. The Lower Colorado River Authority (LCRA), Fayette Power Project (FPP) consists of two 683.7 MVA tandem compound steam turbine driven generators. The excitation systems are of the ...

1983-02-01

170

Power plants 2010. Lectures  

International Nuclear Information System (INIS)

The proceedings include the following lectures: Facing the challenges - new structures for electricity production. Renewable energies in Europe - chances and challenges. Nuclear outlook in the UK. Sustainable energy for Europe. Requirements of the market and the grid operator at the electricity production companies. Perspectives for the future energy production. Pumped storage plants - status and perspectives. Nuclear power/renewable energies -partners or opponents? New fossil fired power stations in Europe - status and perspectives. Nuclear energy: outlook for new build and lifetime extension in Europe. Biomass in the future European energy market - experiences for dong energy. Meeting the EU 20:20 renewable energy targets: the offshore challenges. DESERTEC: sustainable electricity for Europe, Middle East and North Africa. New power plants in Europe - a challenge for project and quality management. Consideration of safely ...

2010-09-22

171

Optimal security-constrained power scheduling by Benders decomposition  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a Benders decomposition approach to determine the optimal day-ahead power scheduling in a pool-organized power system, taking into account dispatch, network and security constraints. The study model considers the daily market and the technical constraints resolution as two different and consecutive processes. The daily market is solved in a first stage subject to economical criteria exclusively and then, the constraints solution algorithm is applied to this initial dispatch through the redispatching method. The Benders partitioning algorithm is applied to this constraints solution process to obtain an optimal secure power scheduling. The constraints solution includes a full AC network and security model to incorporate voltages magnitudes as they are a critical factor in some real power systems. The algorithm determines the active power committed to each ...

2007-05-15

172

WWER steam generator transients during loss of coolant accidents  

International Nuclear Information System (INIS)

A nonlinear mathematical model is presented of a WWER-440 nuclear power plant horizontal steam generator. On the proposed model is based a computer program for investigating transients in steam generators during loss of coolant accidents. Processes taking place at the primary side of the steam generator are described by a set of partial differential equations while those at the secondary side of the steam generator are described by plain differential equations with the variables being complex time functions. The model takes account of the coolant as both a single- and two-phase medium, of changes in the direction of the primary coolant flow and of changes in the direction of heat transfer. Heat transfer through the wall is based on a simple model of heat transfer through a thin-walled tube and includes a correction for the heat resistance of the wall. (author).

1978-01-01

173

Electricity generation from rice husk in Indian rice mills: potential and financial viability  

Energy Technology Data Exchange (ETDEWEB)

Rice husk generated as a by-product of rice processing is an important energy resource. The availability of this resource in India has been assessed and the technologies for exploitation of its energy potential in rice processing industry discussed. Nomographs have been developed for estimation of the husk required to meet the energy demand of parboiling, drying and milling operations. The unit cost of electricity using rice husk gasifier-based power generation systems has been calculated and its financial feasibility assessed in comparison with utility-supplied and diesel-generated electricity. With the cost and efficiency data assumed here, the unit cost of electricity produced by rice husk gasifier-dual fuel engine-generator system varies between Rs 2/kWh and Rs 7/kWh. (author)

1996-10-01

174

Electricity generation from rice husk in Indian rice mills: potential and financial viability  

Energy Technology Data Exchange (ETDEWEB)

Rice husk generated as a by-product of rice processing is an important energy resource. The availability of this resource in India has been assessed and the technologies for exploitation of its energy potential in the rice processing industry discussed. Nomographs have been developed for estimation of the husk required to meet the energy of parboiling, drying and milling operations. The unit cost of electricity using rice husk gasifier-based power generation systems has been calculated and its financial feasibility assessed in comparison with utility-supplied and diesel-generated electricity. With the cost and efficiency data assumed here, the unit cost of electricity produced by rice husk gasifier-dual fuel engine-generator system varies between Rs 2/kWh and Rs 7/kWh. (35 Rs approximates to SUS 1.). (author)

1998-12-31

175

Hydroelectric power in Switzerland: large growth potential by increasing the installed power; L'hydraulique suisse: un grand potentiel de croissance par l'augmentation de la puissance  

Energy Technology Data Exchange (ETDEWEB)

Due to its important hydroelectric power generation facilities (about 525 plants with a total power of 13,314 MW producing about 35.3 TWh annually) Switzerland plays an important role in the interconnected European power system. Large artificial storage lakes in the Swiss Alps can generate peak power during hours of highest demand: 9700 MW are available from accumulated energy and the total power of pumped-storage facilities amounts to 1700 MW. The latter allow refilling the reservoirs at periods of low power demand and generating power at periods of peak demand. In the case of favorable conditions, the yearly average power production could be increased by 6% and the production during the winter period (October to March) by 20% by the year 2020. However, ...

2007-07-01

176

Validation studies of thermal-hydraulic code for safety analysis of nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

The thesis gives an overview of the validation process for thermal-hydraulic system codes and it presents in more detail the assessment and validation of the French code CATHARE for VVER calculations. Three assessment cases are presented: loop seal clearing, core reflooding and flow in a horizontal steam generator. The experience gained during these assessment and validation calculations has been used to analyze the behavior of the horizontal steam generator and the natural circulation in the geometry of the Loviisa nuclear power plant. Large part of the work has been performed in cooperation with the CATHARE-team in Grenoble, France. (41 refs., 11 figs., 8 tabs.).

1995-12-31

177

Solar-powered refrigerator unit with solar module and transport equipment as stand-alone compact system. Solarkuehlgeraet mit Solarmodul und Transportvorrichtung als autonomes Kompaktsystem  

Energy Technology Data Exchange (ETDEWEB)

A compact and energy independent solar-powered refrigeration unit was to be developed to store and transport small quantities of high-quality commodities needing refrigeration. This unit comprises the following matched components: thermo-electrical refrigerator unit, solar generator and transport equipment. The solar generator is a specially developed panel with 36 cells. This unit may best be used in human medicine, veterinary medicine, environmental protection analysis, laboratories and leisure time activities. (BWI)

1994-01-01

178

Proceedings of national conference on operating experience of nuclear reactors and power plants: book of preprints  

International Nuclear Information System (INIS)

The symposium covers papers under different sections namely, (i) Core physics and Fuel management, (ii) Commissioning of facilities and systems, (iii) Operational experience and Human resource development, (iv) Fuel handling, Maintenance management and Surveillance, (v) Instrumentation and Control and Power supply systems, (vi) Analysis, modifications and developments for enhancing operational safety, (vii) Chemistry control and Effluent management, (viii) Radiation and industrial safety and (ix) Steam generators, Turbo-generators and other auxiliaries. Papers relevant to INIS are indexed separately. (author)

2006-11-13

179

On the threshold of the 21st Century in the Soviet Union  

International Nuclear Information System (INIS)

In the last 30 years the production of electricity in the USSR has increased 14-fold, probably attaining 1540 billion kWH in 1985. Nuclear generation will provide the bulk of future increases of consumption, using both water-cooled and uranium/graphite reactors; stations of up to 1.5 million kW are in service. The USSR is also in the fore-front of attempts to exploit thermonuclear power. The USSR is also conducting experiments with renewable sources of energy such as solar, geothermal, wind and wave power and with magnetohydrodynamic generation. (D.A.J.).

180

On the Generation of a Robust Residual for Closed-loopControl systems that Exhibit Sensor Faults  

DEFF Research Database (Denmark)

This paper presents a novel design methodology, based on shaping the system frequency response, for the generation of an appropriate residual signal that is sensitive to sensor faults in the presence of model uncertainty and exogenous unknown (unmeasured) disturbances. An integrated feedback controller design and robust frequency-based fault detection approach is proposed for Single-Input/Single-Output systems. The effciency of the proposed method is demonstrated on a Single Machine Innite Bus (SMIB) power system that achieves a coordinate power system stabilizer with satisfactory sensor fault detection capabilities.

2007-01-01

181

Non-linear mathematical model of dynamics of horizontal steam generator for nuclear power unit with pressurized water reactor  

International Nuclear Information System (INIS)

A non-linear mathematical model of dynamics of horizontal steam generator for nuclear power unit with WWER type reactor is presented. To realize this model the GEMMA-120 simulation language for computer Odra-1204 has been used. Necessity of taking into account disposited thermal storage capacities along tubulation of a primary cycle is demonstrated. A number of lumped elements of reactor division against a required static accuracy of calculations has been determined. (author).

1977-01-01

182

Measuring preferences for low-carbon energy technologies in South-East England: the case of electricity generation  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a survey on public preferences in SE England for the use of wind, biomass and nuclear power in electricity generation. Using a labelled CE the perceived importance (value) to the public of distance and the energy options' impacts on biodiversity, emissions, land occupation and household cost was explored. Results suggest that impacts, technology name, demographic characteristics, attitudes towards the environment, knowledge and experience with the technologies were significant choice determinants. Considering the current debate about the development of nuclear power and biomass in UK and worldwide, this survey provides an insight into the factors affecting public acceptability

2008-07-01

183

Experimental generation of non-Kolmogorov turbulence using a liquid crystal spatial light modulator  

Science.gov (United States)

Several experiments showed that the classical Kolmogorov power spectral density of the refractive-index sometimes does not properly describe the statistics of the atmosphere. In this paper we show an experimental testbed able to generate non-classical Kolmogorov turbulence by using a liquid crystal spatial light modulator. The testbed is used at Naval Postgraduate School for laboratory investigation of laser beam propagation in maritime environment where a power law different from classical Kolmogorov, 11/ 3, could be present. Applications of this testbed are ship to-ship free space optical communication, imaging and high energy laser weapons.

2011-09-01

184

A self-organizing power system stabilizer using Fuzzy Auto-Regressive Moving Average (FARMA) model  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a self-organizing power system stabilizer (SOPSS) which use the Fuzzy Auto-Regressive Moving Average (FARMA) model. The control rules and the membership functions of the proposed logic controller are generated automatically without using any plant model. The generated rules are stored in the fuzzy rule space and updated on-line by a self-organizing procedure. To show the effectiveness of the proposed controller, comparison with a conventional controller for one-machine infinite-bus system is presented.

1996-06-01

185

Safety analysis program for steam generators replacement and power uprate at Tihange 2 nuclear power plant  

International Nuclear Information System (INIS)

The Belgian Tihange 2 nuclear power plant went into commercial operation in 1983 producing a thermal power of 2785 MW. Since the commissioning of the plant the steam generators U-tubes have been affected by primary stress corrosion cracking. In order to avoid further degradation of the performance and an increase in repair costs, Electrabel, the owner of the plant, decided in 1997 to replace the 3 steam generators. This decision was supported by the feasibility study performed by Tractebel Energy Engineering which demonstrated that an increase of 10% of the initial power together with a fuel cycle length of 18 months was achieved. Tractebel Energy Engineering was entrusted by Electrabel as the owner's engineer to manage the project. This paper presents the role of Tractebel Energy Engineering in this project and the safety analysis program necessary to justify the new operation ...

2002-08-11

186

Reducing the effect of penstock pressure pulsations on hydro electric plant power system stabilizer signals  

Energy Technology Data Exchange (ETDEWEB)

A characteristic trait of Francis turbines operating at low-head is pressure pulsations that occur during certain load levels of the generator. These stem from pressure variations across the turbine due to pulsating flow in the draft-tube. This surging action of the water column is related to draft-tube geometry and flow-rate of water in the penstock. The pressure pulsations cause torque variations on the turbine and corresponding electric power pulsations. If electric power is used as a feedback signal to the Power System Stabilizer (PSS), then Mvar and terminal voltage pulsations will occur when the generator is operating in the ``rough zone``. This paper describes field test results for investigating feedforward control from the penstock, draft tube and spiral case pressure to reduce the effects of Mw pulsations on PSS output signals. This investigation involved a PSS with ...

1993-12-01

187

MIMO (multi-input multi-output) adaptive power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

A multivariate adaptive power system stabilizer is proposed. The advantages of using coordinated governor and excitation control are discussed, and the problems associated with constant parameter power system stabilizers (CPSS) are highlighted. The proposed multi-input multi-output (MIMO) power system stabilizer can coordinate the governor and excitation control and can overcome the problems associated with CPSS in power system stabilization. Selective multivariable state modelling, identification and control methods are investigated and the MIMO least squares technique with variable forgetting factor is used for system identification, guaranteeing good parameter tracking after a disturbance. Two multivariable self-tuning algorithms are investigated, the generalized minimum variance control and pole-shifting control algorithms. The multivariable self-searching pole-shifting algorithm is developed. ...

1988-01-01

188

Environmental economics and design considerations to commercialize solar thermal power generation in megawatt (MW) range  

Energy Technology Data Exchange (ETDEWEB)

A wider use of renewable energy sources is considered to be the solution to fossil fuel depletion and environmental pollution. This paper discusses various design considerations for line focussing technology to achieve high efficiency and the possibility of generating power in the megawatt range based on solar thermal technologies. The impacts on the environment of conventional thermal power plants is outlined and an estimate made of the cost of pollution abatement measures. A cost benefit analysis is made using a typical 200 megawatt solar thermal plant, 500 km from the load centre, compared with a 220 megawatt coal fired and a similar capacity gas fired power plant, as examples. The results indicated that the energy from the solar thermal power plant is almost twice as expensive compared to conventionally generated electricity. If, however, impacts on the ...

1995-12-31

189

Environmental economics and design considerations to commercialise solar thermal power generation in megawatt (MW) range  

Energy Technology Data Exchange (ETDEWEB)

A wider use of renewable energy sources is considered to be the solution to fossil fuel depletion and environmental pollution. This paper discusses various design considerations for line focussing technology to achieve high efficiency and the possibility of generating power in the megawatt range based on solar thermal technologies. The impacts on the environment of conventional thermal power plants is outlined and an estimate made of the cost of pollution abatement measures. A cost benefit analysis is made using a typical 200 megawatt solar thermal plant, 500 km from the load centre, compared with a 220 megawatt coal fired and a similar capacity gas fired power plant, as examples. The results indicated that the energy from the solar thermal power plant is almost twice as expensive compared to conventionally generated electricity. If, however, impacts on the ...

1995-12-31

190

Evaluation of containment P/T relating feedwater flow rate analysis following main steam line break accident for nuclear power plant  

Energy Technology Data Exchange (ETDEWEB)

The Feedwater System supplies feedwater to the steam generator at the required pressure, temperature and flow rate during the plant start-up, normal power operation, shutdown. When the Feedwater System is inoperable or unavailable, the Auxiliary Feedwater System supplies emergency feedwater to the steam generator. If main steam line break occurs, the increase of feedwater flow rate of the faulted steam generator due to decrease of the pressure in the faulted steam generator results in adverse effects in aspect of overcooling the Reactor Coolant System and increased containment pressure/temperature. To optimize the containment mass/energy analysis, this paper evaluates the maximum feedwater and auxiliary feedwater flow rate delivered to the faulted steam generator at each stage of pressure decrease in the faulted steam generator after a main ...

2001-05-01

191

Design of electron beam accelerators for microwave application  

Energy Technology Data Exchange (ETDEWEB)

Relativistic electron beams are used for generating high power microwaves. These microwave sources require electron beam generators spanning significant ranges in voltage and impedance. The pulsed power technology used to generate these electron beams is presented. Electron beam generators that produce beams with pulse durations in the 10-ns to 100-ns regime consist of an energy-storage section, pulse-shaping section, and an electron beam diode. The energy-storage section is either a Marx generator or capacitor bank-pulsed transformer. The pulse shaping is done with high-voltage transmission lines. The electron beam diode is usually a cold-cathode, space-charge-limited flow device. For longer pulses (/approximately/1 ..mu..s) the energy storage and pulse chaping can be combined. Lumped-element pulse-forming networks (PFN) can be designed to ...

1988-07-01

192

Design of electron beam accelerator for microwave application  

Energy Technology Data Exchange (ETDEWEB)

Relativistic electron beams are used for generating high power microwaves. These microwave sources require electron beam generators spanning significant ranges in voltage and impedance. The pulsed power technology used to generate these electron beams is presented. Electron beam generators that produce beams with pulse durations in the 10 ns to 100 ns regime consist of an energy storage section, pulse shaping section, and an electron beam diode. The energy storage section is either a Marx generator or capacitor bank-pulsed transformer. The pulse shaping is done with high-voltage transmission lines. The electron beam diode is usually a cold-cathode, space-charge-limited flow device. For longer pulses (approx.1 ..mu..s) the energy storage and pulse shaping can be combined. Lumped-element pulsed-forming networks (PFN) can be designed to produce ...

1988-01-01

193

Renewable energy technology for off-grid power generation solar hybrid system  

International Nuclear Information System (INIS)

Off-grid power generation is meant to supply remote or rural area, where grid connection is almost impossible in terms of cost and geography, such as island, aborigine's villages, and areas where nature preservation is concern. Harnessing an abundance renewable energy sources using versatile hybrid power systems can offer the best, least-cost alternative solution for extending modern energy services to remote and isolated communities. The conventional method for off-grid power generation is using diesel generator with a renewable energy (RE) technology utilizing solar photovoltaic, wind, biomass, biogas and/or mini/micro hydro. A hybrid technology is a combination of multiple source of energy; such as RE and diesel generator and may also include energy storage such as battery. In our design, the concept of solar hybrid system is a ...

2006-12-01

194

Transverse velocity modulator and generator schemes based on non-collinear radiation and electron beams  

International Nuclear Information System (INIS)

New non-collinear schemes are suggested for transverse velocity modulation of electron beams and for the generation of coherent spontaneous radiation by these transversely modulated beams. It is shown that due to the non-collinearity some orders of magnitude enhancement can be achieved for the coherent spontaneous radiation (CSR) power at both the fundamental and harmonic frequencies.

2000-05-01

195

The second generation of the 2. 5 litre direct injection diesel engine. Die zweite Generation des Ford 2,5-l-Diesel-Direkteinspritzmotors  

Energy Technology Data Exchange (ETDEWEB)

The design changes of the improved 2,5 l direct injection Diesel engine with the nominal power output of 52 kW and a maximum torque of 143 Nm are described. This engine which is installed in the Ford Transit meets all relevant exhaust emission standards that are presently in effect. (orig.).

1989-06-01

196

System for the co-production of electricity and hydrogen  

Science.gov (United States)

Described herein is a system for the co-generation of hydrogen gas and electricity, wherein the proportion of hydrogen to electricity can be adjusted from 0% to 100%. The system integrates fuel cell technology for power generation with fuel-assisted steam-electrolysis. A hydrocarbon fuel, a reformed hydrocarbon fuel, or a partially reformed hydrocarbon fuel can be fed into the system.

2007-10-02

197

Horizontal steam generator modelling with CATHARE; validation of several nodalization schemes on plant data  

Energy Technology Data Exchange (ETDEWEB)

The results of the development work to improve the horizontal steam generator modelling using the CATHARE code as well as the results of the steady-state and the steam-line break calculations are presented. Also the results of the steady-state calculations are compared to the measurements performed in operating VVER power plants. (9 refs., 6 figs., 2 tabs.).

1993-12-31

198

Horizontal steam generator modelling with CATHARE; validation of several nodalization schemes on plant data  

International Nuclear Information System (INIS)

The results of the development work to improve the horizontal steam generator modelling using the CATHARE code as well as the results of the steady-state and the steam-line break calculations are presented. Also the results of the steady-state calculations are compared to the measurements performed in operating VVER power plants. (9 refs., 6 figs., 2 tabs.).

1992-09-29

199

Explosion protection in nuclear power plants with LWR and HTR reactors. As of August 14, 1989. Explosionsschutz in Kernkraftwerken mit Leichtwasser- und Hochtemperaturreaktoren (allgemeine und fallbezogene Anforderungen). Vom 14. August 1989  

Energy Technology Data Exchange (ETDEWEB)

The technical rule intends to maintain the function of the safety facilities in case of explosion hazards resulting from materials capable of generating explosive atmospheres or forming explosive mixtures if such materials are brought or released into the nuclear facility or are generated on site. (orig.).

1989-12-07

200

Explosion protection in nuclear power plants with LWR and HTR reactors (general and case depending requirements). Explosionsschutz in Kernkraftwerken mit Leichtwasser- und Hochtemperaturreaktoren (allgemeine und fallbezogene Anforderungen)  

Energy Technology Data Exchange (ETDEWEB)

The technical rule intends to maintain the function of the safety facilities in case of explosion hazards resulting from materials capable of generating explosive atmospheres or forming explosive mixtures if such materials are brought or released into the nuclear facility or are generated on site. (orig.).

1989-01-01

201

Coolant stratification and its thermohydrodynamic specificity under natural circulation in horizontal steam generator collectors  

Energy Technology Data Exchange (ETDEWEB)

The experiments and the test facilities for the study of the stratification phenomenon in the hot plenum of reactor and the upper parts of the steam generator collectors in a nuclear power plant are described. The aim of the experiments was to define the conditions of the stratification initiation, to study the temperature field in the upper part, the definition of the characteristics in the stratification layer, and also to study the factors which cause the intensity of the stagnant volume cooling.

1997-12-31

202

Managing system for mounted parts and spare parts of power source facilities  

Energy Technology Data Exchange (ETDEWEB)

The power source facilities of JT-60 consist of poloidal magnetic coil power source, toroidal magnetic coil power source, the power generation facility for heating, operation power distribution facility and secondary cooling facility, and at the time of the experiment operation of JT-60, they supply 1300 MVA of instantaneous maximum power to loads. The component machinery and equipment of the power source facilities are installed in about 20 indoor and outdoor places, and their mounted parts are about 15,000 kinds. About 3,000 kinds of spare parts are preserved in 15 exclusively used stores. The managing system for mounted parts and spare parts of JT-60 power source facilities which possesses the functions of rapidly and efficiently carrying out the storage of large quantity of information, mutual ...

1995-07-01

203

TVA's program to mitigate steam generator denting at Sequoyah and Watts Bar Nuclear Plants  

International Nuclear Information System (INIS)

TVA is currently engaged in an extensive program to mitigate steam generator tube denting at the Sequoyah Nuclear Plant, which is in commercial operation, and to prevent or minimize the onset of denting at the Watts Bar Nuclear Plant, which is under construction. This paper describes TVA's denting mitigation program, which is primarily feedwater chemistry and system operation improvement, and the effect the changes that have been implemented have had on the incidence as well as the progression rate of steam generator tube denting during the past 220 effective full power days of Sequoyah unit 1 operation.

1983-09-25

204

3 phase-3 wire 10kW interconnected inverter for photovoltaic power generation; Sanso sansen 10kW taiyoko hatsuden`yo keito renkei inverter  

Energy Technology Data Exchange (ETDEWEB)

Inverter introduced in this paper is intended for use in medium-capacity photovoltaic power generation systems designed for industries in general. Interconnection is carried out at a low-voltage 210V point receiving from a commercial 3 phase-3 cable 6.6kV high voltage incoming panel. So as to ensure stable extraction of power in the maximum degree from a photovoltaic power generation system that is naturally unstable, this inverter monitors voltage and power, and behaves in a fully automated way. A maximum power point tracking (MPPT) control function is provided, which measures the power level at the current operating voltage point A, changes the operating voltage to a voltage value B which is lower than the point A voltage by 3V and to a voltage value C which is higher than the point A voltage by 3V, and measures the ...

1997-10-30

205

The role of small and medium reactors in the energy security of a country, IRIS example  

International Nuclear Information System (INIS)

Nuclear options for electricity generations are assessed in this paper. Probabilistic (stochastic) method is used for economic comparison of nuclear power plants, wind plants and natural gas fired plants. Optimal nuclear power plant size is also discussed. IRIS is presented as a representative of small and medium reactors

2009-05-26

206

Testing modern protective relays  

Energy Technology Data Exchange (ETDEWEB)

Modern microprocessor-based relays for the protection of the various power system components such as generators, transformers, feeders, and high voltage transmission lines are becoming more sophisticated as increasingly more complex functions and capabilities can be included in the microprocessor. With this increasing complexity, and the increasing complexity of the power system itself, there is even more value in testing the suitability of relaying equipment for the intended applications. This paper reviews the testing philosophy, experience, and capabilities developed at Ontario Hydro over more than 25 years of testing protective relays.

1994-01-01

207

Satellite power systems (SPS) concept definition study (Exhibit D). Volume 4, Part 2: cost and programmatics appendix. Final report  

Energy Technology Data Exchange (ETDEWEB)

Cost and programmatic aspects of a recommended satellite power system are documented. Computer generated summaries are presented, and the detailed computer runs structured in a Work Breakdown Structure are given. The six configurations developed during the study period are summarized.

1981-03-01

208

Repowering: improving the economics of existing assets  

Energy Technology Data Exchange (ETDEWEB)

Restructured power markets require concepts not only for extending the lifetime of existing plants, but also concepts for reducing the life-cycle costs of existing older steam power plants in order to remain competitive with the most modern and advanced power generation technology such as combined cycle power plants. Out of the broad range of methods to extend service life and increase availability, and to increase power output and efficiency, this paper focuses on full repowering. Full repowering replaces the old fired boiler with gas turbine(s) and heat-recovery steam generators (HRSG) as heat input to the existing bottoming cycle and reuses the steam turbine (ST) condenser and further balance of plant (BOP) equipment. The potential offered by this concept is demonstrated. Repowering and modernization projects are executed if they result ...

2005-07-01

209

Preliminary design of a solar central receiver for a site-specific repowering application (Saguaro Power Plant). Volume III. Specifications. Final report, October 1982-September 1983  

Energy Technology Data Exchange (ETDEWEB)

This volume on specifications for the Saguaro Power Plant includes the following: subsystem interface definition document; solar collector subsystem specification; receiver specification; thermal energy storage specification; solar steam generator specification; and master control system specification.

1983-09-01

210

Negative ion formation in magnetically insulated transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Negative ion intensities of over 3 x 10/sup 5/ A/m/sup 2/ at energies of 2 MeV have been measured in a magnetically insulated transmission line. This negative ion production can affect the power flow in multiterawatt pulsed power devices, and may also have applications in the generation of high-intensity neutral or negative ion beams.

1982-05-01

211

Hungarian experience in using the IAEA planning methodologies  

International Nuclear Information System (INIS)

The Hungarian Power Companies Ltd. has been using the IAEA planning methodologies since 1985 when it acquired the WASP model. Since then this model has been applied on a regular basis to determine the least cost expansion plan of the power generating system of the country. This report describes this experience as well as the application of the WASP model for other types of studies. (author).

1997-09-01

212

Geodesy problems in nuclear power plant construction  

Energy Technology Data Exchange (ETDEWEB)

The special geodetic problems encountered during the construction of the Paks nuclear power plants are treated. The main building with its hermetically connected components including the reactor, the steam generators, the circulation pumps etc. impose special requirements on the control net of datum points. The geodesy tasks solved during the construction of the main building are presented in details.

1981-01-01

213

Experiences with the first 18 months. Act on Power Generatiom from Renewable Energy Sources (EEWaermeG); Erfahrungen mit den ersten 18 Monaten. Erneuerbare-Energien-Waermegesetz (EEWaermeG)  

Energy Technology Data Exchange (ETDEWEB)

Clear effects of the Act on Power Generation from Renewable Energy Sources (EEWaermeG) on the market cannot be recognized both for the depth geothermal energy and ground source geothermal energy. Due to the concrete design of the law a position that is inferior to others is attained in relation to some other renewable energy sources.

2010-12-15

214

Electricity on the rig. Part 3 - New electric rig technology  

Energy Technology Data Exchange (ETDEWEB)

The use of an SCR-controlled power system on an offshore drilling rig has lead to an increased acceptance of high technology equipment. Such equipment increases drilling productivity, reduces maintenance, and improves reliability. Most new rigs now have AC squirrel cage motors, brushless AC generators, silicon controlled rectifiers, DC motors, and swtichgear and motor starters. Several opportunities for cost reductions in SCR systems, such as improving the power factor, are studied in this paper.

1983-07-01

215

Developments in geothermal energy in Mexico. Pt. 7. Thermodynamic analysis of the operation of geothermal electric power generation facilities  

Energy Technology Data Exchange (ETDEWEB)

The operating histories and performance of a large (180 MWsub(e)) central condensing plant and five small (5 MWsub(e)) wellhead backpressure power plants are presented. The thermodynamic performance of the central plant is compared with an estimated possible performance based upon the work of Michaelides. Both types of plant have been shown to be reliable despite some problems due to the contaminants which are associated with geothermal steam.

1986-01-01

216

Development of Hardware for Power System Stabilizer (PSS)  

Energy Technology Data Exchange (ETDEWEB)

The basic function of a Power System Stabilizer (PSS) is to add damping to the generator rotor oscillations by controlling its excitation using auxiliary stabilizing signals. To provide damping, the stabilizer must produce a component of electrical torque in phase with the rotor speed deviations. This paper introduces the hardware specifications and various functions of microprocessor (TMS320C32)-based digital PSS to provide the damping torque. (author). 3 refs., 6 figs.

2001-07-01

217

Basic consideration on high power free-electron lasers  

Energy Technology Data Exchange (ETDEWEB)

An FEL amplifier to generate a laser power of the order of TW at 4 {mu}m wavelength is investigated for a {gamma}-{gamma} collider. A concept of an amplifier chain consisting of a phase-displacement deceleration FELs is proposed to increase the FEL efficiency and to mitigate the requirement for the beam energy spread. The feasibility of the driving linac for the FEL system is also discussed. ((orig.)).

1995-02-01

218

Basic consideration on high power free-electron lasers  

International Nuclear Information System (INIS)

An FEL amplifier to generate a laser power of the order of TW at 4 #mu#m wavelength is investigated for a #gamma#-#gamma# collider. A concept of an amplifier chain consisting of a phase-displacement deceleration FELs is proposed to increase the FEL efficiency and to mitigate the requirement for the beam energy spread. The feasibility of the driving linac for the FEL system is also discussed. ((orig.)).

219

A multigroup multiparticle formalism for multiplying systems Kolmogorov equations in the space-independent low-power model  

International Nuclear Information System (INIS)

The time-dependent probability distribution of neutrons, precursors and detectrons in a space-independent, low-power, multiplying assembly with a source is developed in the multigroup approximation as forward and backward Kolmogorov equations. The relationship between these as adjoint equations is made explicit in a tensor notation and the equations developed in the generating-function formalism. (author).

1982-01-01

220

Feasibility study on Bobovdol thermal power plant upgrading project  

Energy Technology Data Exchange (ETDEWEB)

A survey has been made in relation with the improvement project intended of energy conservation, and reduction of global warming gas emission at the Bobovdol thermal power plant located in the suburb of Sofia, the capital of the Republic of Bulgaria. The existing Bobovdol power plant having a total capacity of 630 MW with three generators is a coal burning thermal power plant having been used already for 23 to 27 years, hence over-aged. The survey has discussed an improvement project of scrap-and-build type to make the plant a high-efficiency gas combined cycle power plant using gas turbines. The project calls for building 210-MW gas combined power generation facilities having 70-MW gas turbines, one each in three stages in 2007, 2012 and 2017. As a result of the discussions, the fuel consumption reducing rate was found to reach 37.99%, ...

2001-03-01

221

FEOL technology trend  

International Nuclear Information System (INIS)

Trends in front-end-of-line technology are discussed. At the chip level, many of the important parameters are published in the National Technology Roadmap for Semiconductors in 1994. At the device and circuit level, both bipolar and CMOS are scalable. However, the large standby power of bipolar circuits severely limits the integration level of bipolar chips. The inherently low standby power of CMOS, on the contrary, allows the integration level of CMOS circuits to continue increasing with scaling. In reality, both the electric field and power density of CMOS devices have been gradually rising over the generations owing to non-scaling effects of thermal voltage and silicon bandgap. As power supply voltage reaches 1.5V and below, circuit performance can only be gained at the expense of higher active or standby power of the chip. Implications of device scaling on ...

222

Alternative cycles based on carbon dioxide for central receiver solar power plants  

British Library Electronic Table of Contents (United Kingdom)

Research in concentrated thermal solar power plants of all types and, in particular, those based on central receiver, namely solar tower plants, has experienced great impetus in the last decade, reaching full commercial operation with the PS10 plant in Spain. In spite of previous demonstration plants testing different receivers and power cycle layouts, this first commercial power plant adopted a cavity receiver generating saturated steam and therefore penalising cycle efficiency in order to gain plant reliability. According to the experience gained, if a competitive Levelised Cost of Electricity is to be reached, capital and maintenance costs must be reduced and efficiencies must be increased. To achieve these goals, modifying the power cycle is deemed essential, whether using superheated ...

2011-01-01

223

Regional application of natural-gas-fired combined-cycle power generation  

Energy Technology Data Exchange (ETDEWEB)

The results of a study assessing natural-gas-fired combined-cycle (GFCC) power generation in the electric-utility sector are presented. This study quantified the economic benefits attributable to GFCC generation and examined the characteristics of GFCC technology that produce these benefits and the ways that these benefits vary among regions in the country. The impacts of changes in important economic parameters (capital cost, fuel price, etc.) as well as the impact of advances in GFCC technology were considered. Use of GFCC technology in the electric-utility sector could play an important role in a least-cost planning strategy and thereby provide significant benefits to the utilities and their customers. Potential benefits include reduced capital and operating costs, more effective matching of load growth and capacity additions, and greater system reliability. 8 refs., 3 tabs.

1989-01-01

224

Microwave melting device  

Energy Technology Data Exchange (ETDEWEB)

Low level radioactive wastes (concrete pieces) or materials to be melted such as burnt ashes of wastes are charged into a melting furnace. Then, gyrotron of a microwave generator is oscillated, and generated microwaves of a large power are introduced to a melting furnace by a waveguide. The microwaves are irradiated from an irradiator to a beam converging-type reflecting mirror antenna disposed opposite to the irradiator. Then, an antenna driving portion is operated to rotate and move the antenna in parallel. With such procedures, the microwaves of a large power are converged acutely in a beam-like manner to a predetermined range in the melting furnace, and the converged beams of the microwaves are scanned. This can generate heat from the inner side of the materials to be melted charged to the melting furnace by the induction loss and they are melted. (I.N.)

1997-05-02

225

Emissions trading and green power : profitability for buyers and sellers  

Energy Technology Data Exchange (ETDEWEB)

Proposed features of the competitive electricity market in Ontario were reviewed. The speaker predicted that demand for renewable energy in Ontario`s competitive electricity market will be affected by green power, emissions trading, labelling, and renewables portfolio standard. Under current regulations retailers can charge customers a premium for purchasing electricity generated by `green` sources. The existing limits on emissions of sulphur dioxide, nitrogen oxides and carbon dioxides will remain in place, but an emissions cap and trading program for all Ontario-based generation is an option to consider. Ontario`s Market Design Committee (MDC) has recommended the implementation of emissions trading for electricity-related air pollutants for all generators located in Ontario. The complex mechanics of emission trading are explained. The MDC recommendation of the use of standard labels to disclose the ...

1998-12-31

226

Electric power monthly  

Energy Technology Data Exchange (ETDEWEB)

The Electric Power Monthly is prepared by the Survey Management Division; Office of Coal, Nuclear, Electric and Alternate Fuels, Energy Information Administration (EIA), Department of Energy. This publication provides monthly statistics at the national, Census division, and State levels for net generation, fuel consumption, fuel stocks, quantity and quality of fuel, cost of fuel, electricity sales, revenue, and average revenue per kilowatthour of electricity sold. Data on net generation, fuel consumption, fuel stocks, quantity and cost of fuel are also displayed for the North American Electric Reliability Council (NERC) regions. Additionally, statistics by company and plant are published in the EPM on capability of new plants, new generation, fuel consumption, fuel stocks, quantity and quality of fuel, and cost of fuel.

1992-05-01

227

UK's Sizewell inquiry; funny how time slips away  

Energy Technology Data Exchange (ETDEWEB)

Comments are made on the Public Inquiry into CEGB's proposal to construct a pressurized water reactor (PWR) at Sizewell, UK. Aspects discussed include: time elapsed and its possible effect on the result; economics of nuclear power plants compared with coal-fired power plants; changes in real sterling/dollar exchange rates; effect of mineworkers' strike; the UK electric power generating system; AGR reactors compared with PWR reactors; extension of Magnox reactor life; radioactive waste management; political decisions.

1985-03-01

228

State-of-the-art technique for power system stabilizer tuning  

Energy Technology Data Exchange (ETDEWEB)

Power System Stabilizers (PSS) have broad application throughout the world. PSS application requires careful tuning which is usually accomplished in the field with the generator and power system in an abnormal condition. Recently developed equipment which combines fast Fourier transform capability with digital computer technique provides a means of PSS tuning which is faster and more accurate than was previously obtainable. This paper describes a PSS tuning test conducted using the new technique. The advantages will be apparent to the reader. The described test is very poignant as evidenced by two unexpected occurrences of instability.

1983-03-01

229

Real time estimation of photovoltaic modules characteristics and its application to maximum power point operation  

Energy Technology Data Exchange (ETDEWEB)

In this paper, an approximate curve fitting method for photovoltaic modules is presented. The operation is based on solving a simple solar cell electrical model by a microcontroller in real time. Only four voltage and current coordinates are needed to obtain the solar module parameters and set its operation at maximum power in any conditions of illumination and temperature. Despite its simplicity, this method is suitable for low cost real time applications, as control loop reference generator in photovoltaic maximum power point circuits. The theory that supports the estimator together with simulations and experimental results are presented. (author)

2007-05-15

230

Line-focus solar central power system, Phase I. Final report, 29 September 1978 to 30 April 1980. Volume II. Text  

Energy Technology Data Exchange (ETDEWEB)

The conceptual design, parametric analysis, cost and performance analysis, and a commercial assessment of a 100-MWe high-temperature line-focus central power system are presented. Parametric analyses and conceptual design of the heliostat subsystem, receiver subsystem, heat transport subsystem, energy storage subsystem, electrical power generating subsystem, and master control subsystem are included. A market analysis and development plan are given. (WHK)

1980-04-01

231

500-kV cable lines  

Energy Technology Data Exchange (ETDEWEB)

A detailed description is given of the design, fabrication, and installation of oil-filled 500-kV cable lines used for the first time in the USSR for transmitting electric power from step-up transformers installed several meters from the hydroelectric generators to an outdoor distribution system or a junction point at which they are connected to overhead power transmission lines. These lines are 950 to 1050 m long and they are placed at levels differing by 45 m along the route. These lines can transmit power as great as 630 MV.A.

1980-01-01

232

Insights from Development of Regulatory PSA Model for SMART  

International Nuclear Information System (INIS)

SMART (System-Integrated Modular Advanced Reactor) is a first-of-the-kind integral reactor with 330 MW thermal power under active development by Korea Atomic Energy Research Institute (KAERI) for power generation and seawater desalination. SMART employs various design features that are not typically found in other nuclear power plants. Examples include a unique passive residual heat removal system (PRHRS), and enclosure of a pressurizer, eight helical steam generators, and eight canned reactor coolant pumps inside the reactor pressure vessel. This paper presents risk insights on the SMART reactor gained during the development of a regulatory PSA model by Korea Institute of Nuclear Safety (KINS)

2010-10-01

233

Implementation of a hybrid power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

Dynamic stability enhancement of composite mode oscillations of interconnected power systems by means of a hybrid power system stabilizer is discussed here. The proposed Hybrid PSS is of a two-level structure composed of a local PSS for local mode and a global PSS for inter-area mode damping. Here, the input of the global stabilizer is the center of inertia speed deviation of slow-coherent generators. The paper is focused on the practical considerations in implementation of the proposed stabilizer. First, the optimum allocation of this stabilizer is discussed. The authors introduce an index of mode-input-assignability, by which the best sites of the stabilizer can be identified. Next, for practical applications, an estimation method for the approximation of the input of the global PSS is introduced. An approximated value of the center of inertia speed is obtained from a suitable combination of the rotor speed data of a few ...

1989-11-01

234

Characterization of Filter Elements for Service in a Coal Gasification Environment  

Energy Technology Data Exchange (ETDEWEB)

The Power Systems Development Facility (PSDF) is a joint Department of Energy/Industry sponsored engineering-scale facility for testing advanced coal-based power generation technologies. High temperature, high pressure gas cleaning is critical to many of these advanced technologies. Barrier filter elements that can operate continuously for nearly 9000 hours are required for a successful gas cleaning system for use in commercial power generation. Since late 1999, the Kellogg Brown & Root Transport reactor at the PSDF has been operated in gasification mode. This paper describes the test results for filter elements operating in the Siemens-Westinghouse particle collection device (PCD) with the Transport reactor in gasification mode. Operating conditions in the PCD have varied during gasification operation as described elsewhere in these proceedings (Martin et al, 2002).

2002-09-19

235

Benefit analysis and evaluation of pumped-storage plant in Taipower system  

Energy Technology Data Exchange (ETDEWEB)

The operation of pumped-storage plants (PSP) is based on the daily load variations of power demand. It performs power generation at peak load times during the day, and pumps water up into the reservoir during the off-peak times at night. In the Taipower system in Taiwan, there are two pumped storage plants with ten units. These had a total installed capacity of 2,602 MW or a 12 percent capacity at the end of 1995. The plants were able to reduce system generation costs and improve reliability. A Pumped-Storage Plant Benefit Analysis (PSPBA) program was established using the principle of economic dispatch in 1985. This paper explains the rules of the program, the analysis results of the past 10 years, and a a cost benefit evaluation. It was found that the advantages of PSP are not only in supplying the power for peak load, but also in decreasing the total fuel cost. 5 figs., 4 refs.

1995-12-31

236

Behaviour of the steam generators in the Belgian nuclear power plants  

International Nuclear Information System (INIS)

After a brief review of the degradations occurring on tubes of Inconel 600 in steam generators of PWR power stations emphasis is put on the conditioning of the secondary water and more particularly on the condensate treatment in the units of Doel which work on heavily polluted brackish water. The important role of non-destructive testing and eddy-current testing is also pointed out, method developed by Laborelec. The operational experience shows that Belgian stations are nearly not concerned by the degradations mostly found in power stations in other countries which shows the efficiency of the conditioning of the secondary water. On the other hand, other problems have occurred, resulting from: damage caused by foreign objects; fouling of tube before commissioning, cracking of bends and at the limit of the dudgeoning and leaking plugs. (AF).

1986-04-15

237

Application of an inverse input/output mapped ANN as a power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

An artificial neural network (ANN), trained as an inverse of the controlled plant, to function as a power system stabilizer (PSS) is presented in this paper. In order to make the proposed ANN PSS work properly, it was trained over the full working range of the generating unit with a large variety of disturbances. Data used to train the ANN PSS consists of the control input and the synchronous machine response with an adaptive PSS (APSS) controlling the generator. During training, the ANN was required to memorize the reverse input/output mapping of the synchronous machine. After the training, the output of the synchronous machine was applied as the input of the ANN PSS and the output of the ANN PSS was used as the control signal. Simulation results show that the proposed ANN PSS can provide good damping of the power system over a wide operating range and significantly improve the system performance.

1994-09-01

238

Analysis on fuel economy and advanced systems of hybrid vehicles; Hibrid jidosha no nenpi kojo yoin to shorai tenbo  

Energy Technology Data Exchange (ETDEWEB)

Hybrid vehicles have two power supplies as engine and electric motor which are used most efficiently corresponding to objects respectively to attain energy-saving and low pollution. In this paper, factors concerning the fuel economy of hybrid vehicles and potential thereof are examined, and the possibility of reducing fuel cost by half is described. As possible modes of highly efficient hybrid vehicles, series hybrid vehicles (SHEV) of conventional internal combustion engine, parallel hybrid vehicles using EV in combination, series-parallel hybrid vehicles (SPHV), series type fuel cell type vehicles, ceramic engine-turbo compound power generating SPHV as well as SHEV, and ceramics gas turbine engine power generating SHEV are mentioned. 10 refs., 14 figs.

1997-09-01

239

Abstracts of recent reports: Maryland power plant research program 1992 through 1997  

Energy Technology Data Exchange (ETDEWEB)

The goals of the program include predicting the impact of proposed new generating facilities, evaluating proposed high voltage transmission lines, assessing the impact of existing generating facilities, forecasting future demand for electric power, and investigating numerous information gaps through a long-range research program. The Power Plant Assessment Division (PPAD) is responsible for all PSC licensing support, site specific research, and radiological monitoring. The list of reports summarizes information of over 190 technical publications that represent the Program`s formalized research and monitoring efforts over the last five years. Reports are listed in chronological order by topical heading.

1997-12-01

240

A Design of Fuzzy Power System Stabilizer using Adaptive Evolutionary Computation  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a design of fuzzy power system stabilizer (FPSS) using adaptive evolutionary computation (AEC). We have proposed an adaptive evolutionary algorithm which uses a genetic algorithm (GA) and an evolution strategy (ES) in an adaptive manner in order to take merits of two different evolutionary computations. FPSS shows better control performances than conventional power system stabilizer (CPSS) in three-phase fault with heavy load which is used when tuning FPSS. To show there robustness of the proposed FPSS, it is applied to damp the low frequency oscillations caused by disturbances such as three-phase fault with normal and light load, the angle deviation of generator with normal and light load and the angle deviation of generator with heavy load. Proposed FPSS shows better robustness than CPSS. (author). 15 refs., 13 figs., 3 tabs.

1999-06-01

241

1988 EEI (Edison Electric Institute) power directory  

Energy Technology Data Exchange (ETDEWEB)

Generated annually from the Edison Electric Institute's POWER STATISTICS Data Base, the EEI Power Directory provides state-by-state data on all utility-owned steam-electric plants in the US. The 1988 directory contains the following information for approximately 2500 units located at 1000 generating sites around the country: unit age, capacity, fuel type, and operating status. In addition, solid waste disposal methods for fly ash, bottom ash, and sludge are covered for approximately 1500 US coal-fired units. The directory contains a listing of more than 800 environmental managers and key environmental staff at over 300 utilities, with names, addresses, and telephone numbers. Special indices list plants and utility owner-operators.

1988-05-01

242

A calculation model for thermo-hydraulic analyses of the PGV-1000 steam generator  

International Nuclear Information System (INIS)

A calculation model was developed for the analysis of thermal and hydraulic processes in the PGV-1000 horizontal steam generator. The model makes it possible to examine the hydraulics of the primary medium, i.e., the distribution of flow velocities and mass flows in the exchanger tube system and hydraulic losses of the primary medium in the steam generator during its flow between the two connecting sites to the main circulation pipeline, spatial distribution of heat fluxes between the primary and secondary sides of the steam generator and the total transmitted thermal power, pressure on the secondary side of the generator, natural circulation of the working medium on the secondary side, and the mean circulation number, spatial distribution of the volume fraction of the steam component in the intertubular space, effect of the perforated sheet on the thermo-hydraulic processes in the ...

1994-01-01

243

Achievement report in fiscal 2000. Model project to reduce electric power consumption at cement burning plant; 2000 nendo seika hokoku. Semento shosei plant denryoku shohi sakugen model jigyo  

Energy Technology Data Exchange (ETDEWEB)

In order to serve for efficient energy utilization and environmental improvement in the Republic of Vietnam, a 'Model project to reduce electric power consumption at cement burning plant' has been implemented. This paper summarizes the achievements. This project is intended to add an advanced, matured and reliable electric power generation facility using cement waste heat to the existing cement plant in Vietnam to produce steam and generate power by utilizing the waste heat generated from the preheating process in the burning plant. The present project has performed the detailed designing on the piping, electric facilities and instrumentation based on the basic agreement on the project. Fabrication of the piping has been executed by the Vietnam side. Valves and electric devices were procured and transported, including those fabricated in the ...

2002-03-01

244

Solar-powered unmanned aerial vehicles  

Energy Technology Data Exchange (ETDEWEB)

An analysis was performed to determine the impact of various power system components and mission requirements on the size of solar-powered high altitude long endurance (HALE)-type aircraft. The HALE unmanned aerial vehicle (UAV) has good potential for use in many military and civil applications. The primary power system components considered in this study were photovoltaic (PV) modules for power generation and regenerative fuel cells for energy storage. The impact of relevant component performance on UAV size and capability were considered; including PV module efficiency and mass, power electronics efficiency, and fuel cell specific energy. Mission parameters such as time of year, flight altitude, flight latitude, and payload mass and power were also varied to determine impact on UAV size. The aircraft analysis method used determines the ...

1996-12-31

245

Research and development of new coal based combined cycle power plant concept  

Energy Technology Data Exchange (ETDEWEB)

Out of concern for the global environment, technologies for coal-fired combined cycle power generation are under development throughout the world today, aiming at highly efficient use of coal. Under these circumstances, the authors and others, with the intention of producing a coal-fired combined cycle power generation system with higher plant efficiency, lower construction cost, and higher reliability than conventional systems, proposed a new gasification combined cycle power generation system that differs from the conventional IGCC system. The authors studied system configuration and conducted elementary research necessary for implementing the system. This report deals with the basic concepts of the system and the results of basic studies carried out to realize of the concepts, including a study on alkali metal vapour concentration in relation to heat ...

1997-12-31

246

Recent status of the development of intense ion beams  

Energy Technology Data Exchange (ETDEWEB)

Taking the development of large current, negative ion sources which is in progress aiming at nuclear fusion reactors and the development of high luminance ion sources planned as a part of the Omega Project as the examples, the technology for generating high power ion beams is explained. Both these projects are positioned at the limit of the present technology of high power ion beam application as their targeted beam power reaches several tens MW. Consequently, the requirement for the ion sources is severe, and in particular, the generation of the ion beams having large current density with good convergence is beyond all precedents. The application of high power ion sources has been realized as the neutral beam injectors for large tokamaks. Also the hydrogen negative ion source of large current and the electrostatic acceleration technology for negative ion beams ...

1993-12-01

247

Least cost electricity generation options based on environmental impact abatement  

Energy Technology Data Exchange (ETDEWEB)

The power sector in Thailand is the largest contributor to CO{sub 2} emissions. There is high potential to mitigate CO{sub 2} emission via alternative power generating plants. Alternative plants considered in this study include nuclear plants, integrated gasification combined cycle plants, biomass-based plants and supercritical thermal power plants. The biomass-based plants considered here are fueled with four types of biomass; paddy husk, municipal solid waste (MSW), fuel wood and corncob. The methodology for the optimal expansion plan of the power generating system over the planning horizon is based on the least-cost approach. The results from the least-cost planning analyses show that the nuclear alternative has the highest potential to mitigate not only CO{sub 2} but also other airborne emissions. Moreover, the nuclear option is the most effective abatement ...

2003-12-01

248

Effect of boric acid on steam generator corrosion  

International Nuclear Information System (INIS)

Project RPS116, ''Implementation of Boric Acid in the Field,'' was designed to demonstrate that a selected steam generator boric acid treatment is effective in arresting the progressing of denting in an operating steam generator. The PWR nuclear steam generators chosen for the testing were those at the Indian Point Unit 3 nuclear site. Hydrogen monitoring measurements and eddy current examinations had indicated that the Indian Point Unit 3, Series 44 steam generators had already reached an advanced stage of denting and tube support plate ligament discontinuities were observed. The objective of the boric acid treatment was to reduce the rate of denting by attempting to reproduce in the field the positive results achieved with boric acid in laboratory-simulated denting tests. Laboratory testing has indicated that implementation of a four day low power (25% power) ...

1985-03-01

249

Significance of chemical return in nuclear steam generators  

International Nuclear Information System (INIS)

A reasonable understanding of PWR steam generator corrosion mechanisms such as denting and wastage has been developed, and adequate chemistry control programs defined to obviate the magnitude and effects of these modes of attack. However, relatively unique corrosion attack modes have been encountered at several plants notwithstanding the presence of a reasonable to very good chemistry control program when considered in light of the Steam Generator Owners Group chemistry guidelines. The uniqueness of attack also suggests that parameters not routinely measured or monitored may be playing a significant role. In the authors opinions, the only reasonable method of routinely identifying corrosion accelerating species present in crevices, sludge piles, and deposits in PWR steam generators is by performing detailed chemical return studies during power transients, shutdowns, and long term layups. Although it ...

1985-03-01

250

New technology for purging the steam generators of nuclear power plants  

British Library Electronic Table of Contents (United Kingdom)

A technology for removal of undissolved impurities from a horizontal steam generator using purge water is developed on the basis of a theoretical analysis. A purge with a maximal flow rate is drawn off from the zone with the highest accumulation of sludge in the lower part of the steam generator after the main circulation pump of the corresponding loop is shut off and the temperatures of the heat transfer medium at the inlet and outlet of the steam generator have equilibrated. An improved purge configuration is used for this technology; it employs shutoff and regulator valves, periodic purge lines separated by a cutoff fixture, and a D y 100 drain union as a connector for the periodic purge. Field tests show that the efficiency of this technology for sludge removal by purge water is severa...

2011-01-01

251

Electric power monthly, June 1995 with data for March 1995  

Energy Technology Data Exchange (ETDEWEB)

The Coal and Electric Data and Renewables Division; Office of Coal, Nuclear, Electric and Alternate Fuels, Energy Information Administration (EIA), Department of Energy prepares the EPM. This publication provides monthly statistics at the State, Census division, and US levels for net generation, fossil fuel consumption and stocks, quantity and quality of fossil fuels, cost of fossil fuels, electricity sales, revenue, and average revenue per kilowatthour of electricity sold. Data on net generation, fuel consumption, fuel stocks, quantity and cost of fossil fuels are also displayed for the North American Electric Reliability Council (NERC) regions. The EIA publishes statistics in the EPM on net generation by energy source; consumption, stocks, quantity, quality, and cost of fossil fuels; and capability of new generating units by company and plant. 68 tabs.

1995-06-19

252

Electric power monthly with data for October 1995  

Energy Technology Data Exchange (ETDEWEB)

The Coal and Electric Data and Renewables Division; Office of Coal, Nuclear, Electric and Alternate Fuels, Energy Information Administration (EIA), Department of Energy prepares the EPM. This publication provides monthly statistics at the State, Census division, and U.S. levels for net generation, fossil fuel consumption and stocks, quantity and quality of fossil fuels, cost of fossil fuels, electricity sales, revenue, and average revenue per kilowatthour of electricity sold. Data on net generation, fuel consumption, fuel stocks, quantity and cost of fossil fuels are also displayed for the North American Electric Reliability Council (NERC) regions. The EIA publishes statistics in the EPM on net generation by energy source; consumption, stocks, quantity, quality, and cost of fossil fuels; and capability of new generating units by company and plant.

1996-01-01

253

Interaction between supply and end-use  

Energy Technology Data Exchange (ETDEWEB)

In a future power system with a high proportion of distributed and intermittent generation, it will be difficult and costly to ensure short-term security of supply if demand is unable to react to fluctuations on the supply side. At present, most power consumers in the EU, with the exception of the largest consumers such as energy intensive industries, buy their power on fixed tariffs. Fixed tariffs provide no incentives for consumers to alter their patterns of power consumption. This calls for more interaction between the supply and demand sides, which in turn would allow better matching of demand to intermittent supply. The development of cheap and reliable electronic communication technologies has made this a realistic option, so we are left with the general question of how the demand side can become more active in the future power market. Liberalisation of ...

2005-10-01

254

The role of clean coal technologies in post-2000 power generation  

Energy Technology Data Exchange (ETDEWEB)

A substantial global market for advanced power systems is expected to develop early in the next century for both repowering and new capacity additions, Although natural gas-fueled systems, such as gas turbines, are expected to dominate in the 1990`s, coal-fueled systems are expected to emerge in the 2000`s as systems of choice for base-load capacity because of coal`s lower expected cost. Stringent environmental regulations dictate that all advanced power systems must be clean, economical, and efficient in order to meet both the environmental and economic performance criteria of the future. Recognizing these needs, the DOE strategy is to carry out an effective RD&D program, in partnership with the private sector, to demonstrate these technologies for commercial applications in the next century. These technologies are expected to capture a large portion of the future power generation market. The DOE: ...

1994-07-01

255

Photovoltaic Technologies Beyond the Horizon: Optical Rectenna Solar Cell, Final Report, 1 August 2001-30 September 2002  

Energy Technology Data Exchange (ETDEWEB)

ITN Energy Systems is developing next-generation solar cells based on the concepts of an optical rectenna. ITN's optical rectenna consists of two key elements: (1) an optical antenna to efficiently absorb the incident solar radiation, and (2) a high-frequency metal-insulator-metal (MIM) tunneling diode that rectifies the AC field across the antenna, providing DC power to an external load. The combination of a rectifying diode at the feedpoints of a receiving antenna is often referred to as a rectenna. Rectennas were originally proposed in the 1960s for power transmission by radio waves for remote powering of aircraft for surveillance or communications platforms. Conversion efficiencies greater than 85% have been demonstrated at radio frequencies (efficiency defined as DC power generated divided by RF power incident on the device). ...

2003-02-01

256

Monitoring of power generation from landfill gas at Cory Environmental Ltd., Mucking Marshes  

Energy Technology Data Exchange (ETDEWEB)

The energy recovery scheme at Mucking Marshes landfill site, operated by Cory Environmental Limited, has been in operation since October 1991. Using landfill gas abstracted from the site, a gas turbine generates up to 3.2 MW net electric power for export. Operation and performance of the scheme has been monitored over the period January 1995 to August 1996. Overall performance since the first use of the turbine has also been studied, and has shown reliable and profitable operation. The capital cost of the gas turbine and gas compressor plant was approximately 1.8 million. Actual gas collection wells, pipework, pumping and monitoring facilities, while essential to the scheme, are considered part of the gas control equipment needed for the landfill site. Based on a notional electricity selling price of 4p/kWh, the current annual income from exported power is 550,000. This would be substantially increased by increasing the ...

1996-12-31

257

Light duty mobile, portable and stationary power for military applications  

Energy Technology Data Exchange (ETDEWEB)

Hydrogenics is a leading global developer of hydrogen and fuel cell products for onsite generation and power and test systems. Hydrogenics has been working with the Canadian military since 1996, and also has contracts for portable hydrogen systems with the National American Space Agency (NASA), and the United States Army. This presentation highlighted a number of Hydrogenics' fuel cell technologies for military and commercial applications. Products included portable military generators, electrolysers and reformers, backup power systems, and regenerative satellite systems. Specifications, warranties and power capabilities for the batteries and systems were presented. Details of the company's testing facilities and procedures were provided, as well as a case study of a fuel cell hybrid vehicle. Details of the HyPORT-E 5 kW Regenerative Fuel Cell Auxiliary ...

2006-07-01

258

Hydro power in the German system of energy supply; Wasserkraft im Energiesystem Deutschland  

Energy Technology Data Exchange (ETDEWEB)

The technical potentials of electric power generation from hydro power in Germany, the current harnessing of hydro power, its costs, and certain characteristic quantities reflecting its effects on the environment are described. These diverse characteristic quantities are compared with those of other renewable and fossil energy sources used to generate electricity. On this basis, opportunities for extending the use of hydro power in Germany and its limits are discussed. (orig.) [Deutsch] Das Ziel der folgenden Ausfuehrungen ist, die technischen Potentiale und deren derzeitige Nutzung, die Kosten und bestimmte die Umwelteffekte beschreibende Kenngroessen einer Stromerzeugung aus Wasserkraft in Deutschland darzustellen. Diese unterschiedlichen Kenngroessen werden anschliessend mit denen anderer regenerativer Energien und fossiler Energietraeger zur Stromerzeugung ...

1997-12-31

259

Highlights of design and construction of Sendai Nuclear Power Station Unit No.2  

International Nuclear Information System (INIS)

As for No.2 plant in Sendai Nuclear Power Station, which is the fourth nuclear power generation facilities in Kyushu Electric Power Co., Inc., all works have been completed, and at present, the final trial operation is under way. In No.2 plant, many new techniques for raising the reliability and safety, improving the maintainability and reducing radiation exposure were introduced on the basis of the operation experience of PWRs obtained so far, similarly to No.1 plant. In this paper, the main items of the new techniques related to the design and construction of the plant are reported. No. 2 plant is a first improved and standardized plant having the thermal output of 2660 MW for standard three-loop PWRs, and the rated power output was set at 890 MW. As for the turbine, TC6F-40 in was adopted. As the improved design, a large reactor containment vessel, 17 x 17 type 9-grid fuel, ...

1985-01-01

260

Comparison of advanced engines for parabolic dish solar thermal power plants  

Science.gov (United States)

A paraboloidal dish solar thermal power plant produces electrical energy by a two-step conversion process. The collector subsystem is composed of a two-axis tracking paraboloidal concentrator and a cavity receiver. The concentrator focuses intercepted sunlight (direct, normal insolation) into a cavity receiver whose aperture encircles the focal point of the concentrator. At the internal wall of the receiver the electromagnetic radiation is converted to thermal energy. A heat engine/generator assembly, which is mounted directly behind th receiver, then converts the thermal energy captured by the receiver to electricity. Developmental activity has been concentrated on relatively small power modules which employ 11- to 12-m-diam dishes to generate nominal power levels of approximately 20 kW. A comparison of advanced heat engines for use on the dish power module is ...

1982-09-01

261

China power - thermal coal and clean coal technology export. Topical report  

Energy Technology Data Exchange (ETDEWEB)

China is the world`s fourth largest electric power producer, and is expected to surpass Japan within the next two years to become the third largest power producer. During the past 15 years, China`s total electricity generation more than tripled, increasing from about 300 TWh to about 1,000 TWh. Total installed generating capacity grew at an average of 8.2 percent per year, increasing from 66 to 214 GW. The share of China`s installed capacity in Asia increased from 21 to 31 percent. The Chinese government plans to continue China`s rapid growth rate in the power sector. Total installed capacity is planned to reach 300 GW by 2000, which will generate 1,400 TWh of electricity per year. China`s long-term power sector development is subject to great uncertainty. Under the middle scenario, total capacity is expected to reach 700 GW by 2015, with ...

1996-12-31

262

Severe accident analysis for Wolsung nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

Severe accident analysis has been performed for the Wolsung nuclear power= plants in Korea to investigate severe accident phenomena of CANDU-600 reactors as a part of Level II PSA study. The accident sequence analyzed in this paper is loss of active heat sinks (LOAH) which is caused by loss of off-site power, diesel generators, and DC power. ISAAC (Integrated Severe Accident Analysis Code) computer code developed by KAERI (Korea Atomic Energy Research Institute) was used in this analysis. This paper describes the important thermal-hydraulics and source term behaviors in the primary system and inside containment, and the failure mechanisms of calandria vessel and containment. In addition, some insights for accident management program (AMP) are also given. (Author) 5 refs., 1 tab., 12 figs.

1997-05-01

263

Severe accident analysis for Wolsung nuclear power  

Energy Technology Data Exchange (ETDEWEB)

Severe accident analysis has been performed for the Wolsung nuclear power plants in Korea to investigate severe accident phenomena of CANDU-600 reactors as a part of Level II PSA study. The accident sequence analyzed in this paper is loss of active heat sinks (LOAH) which is caused by loss of off-site power, diesel generators, and DC power, ISAAC(Integrated Severe Accident Analysis Code) computer code developed by KAERI (Korea Atomic Energy Research Institute) was used in this analysis. This paper describes the important thermal-hydraulics and source term behaviors in the primary system and inside containment, and the failure mechanisms of calandria vessel and containment. In addition, some insights for accident management program (AMP) are also given.

1997-05-01

264

Power generation from biomass residues using the gasifier/dual-fuel engine technique  

Energy Technology Data Exchange (ETDEWEB)

A process is described for converting organic waste into a combustible gas for use in a heavy duty thermal engine. The engines best suited for this operation are of the dual-fuel type whose output power results from the simultaneous work of 2 combustibles. The gas flow rate is controlled by the desired power output, while diesel fuel injection remains constant regardless of engine load. The low BTU gas produced by the gasification of dry wastes is a mixture of CO, H/sub 2/ CH/sub 4/, CO/sub 2/ and N/sub 2/. Diesel fuel savings under usual operating conditions is no less than 80% of the consumption of conventional diesel engines of identical power. Characteristics of the low Btu gas engines are described as are the characteristics of the gasifying equipment. Applications for this process are suggested. (DMC)

1980-01-01

265

On-sun test results of McDonnell Douglas` prototype solar thermophotovoltaic power system  

Energy Technology Data Exchange (ETDEWEB)

A solar thermophotovoltaic (STPV) power system has many attractive attributes for both space and terrestrial applications including high efficiency, high reliability, low mass, low operating costs, solar/gas hybrid operation and thermal storage capability for dispatchability. This paper describes the basic components and operation of a STPV system. It also presents the results of on-sun testing with a testbed prototype at operating temperatures of 1,350 C. The design and expected performance of the next generation testbed prototype is discussed. System analysis based upon the test data indicates that power performance in the 23% to 32% can be achieved with a STPV power conversion system using existing technology.

1994-12-31

266

Monte Carlo verification of point kinetics for safety analysis of nuclear reactors  

Energy Technology Data Exchange (ETDEWEB)

Monte Carlo neutron transport methods can be used to verify the applicability of point kinetics for safety analysis of nuclear reactors. KENO-NR was used to obtain the transfer function of the Advanced Neutron Source reactor and the time delay between the core power production and the external detectors, a parameter of interest to the safety systems design. The good agreement between the Monte Carlo generated transfer function and the point kinetics transfer function validates that the uncommon ANS geometry does not preclude the use of point kinetics in the frequency range that was investigated. Various features of the power spectral densities also demonstrated the applicability of point kinetics. The time delay was obtained from the cross-power spectral density (CPSD) and is {approximately}15 ms. These analyses show that frequency analysis can be used experimentally to investigate the validity of the ...

1995-06-01

267

Design modifications in radiation monitoring system at Tarapur Atomic Power Station 3 and 4  

International Nuclear Information System (INIS)

Inputs on radiological conditions forms the basis of implementation of effective exposure control to plant personnel in nuclear power station. Radiation monitoring system provides this input to the plant operator as well as to health physics group. Several design modifications have been incorporated in the Radiation Monitoring System at Tarapur Atomic Power Station (TAPS 3 and 4) over the similar systems at Kakrapar Atomic Power Station (KAPS) and Kaiga Generating Station (KGS). The radiological monitoring systems installed at TAPS unit 3 and 4 includes on line Radiation Data Acquisition System (RADAS), Emergency sampling system, effluent monitoring system and environmental monitoring system. The design changes and the versatile use of these systems are presented in this paper. (author)

2006-11-13

268

Design concepts for simulators of EMP-induced surges in the electric power system  

International Nuclear Information System (INIS)

The nation's electric power system would be subject to induced surges in the event of a high altitude nuclear burst. The HEMP would be coupled to overhead power lines and cause severe overvoltage to components connected to the line. This paper discusses the design of pulsed power equipment needed to simulate this induced EMP. A facility is described which is capable of testing the vulnerability of components by applying appropriate voltage and current waveforms. The pulser can provide waveforms under a variety of test conditions to meet the requirements of different types of components. A 3-5 MV Marx pulser is described. It has the capability of generating a fast rising voltage followed by two distinct exponential decays. The testing of components, charged with their normal voltage is also described.

269

Acid pre-hydrolysis of biomass as a preparation process for its utilization as thermoelectric power plants fuel; Pre-hidrolise acida da biomassa como preparacao de combustivel para termoeletrica  

Energy Technology Data Exchange (ETDEWEB)

It is described a process of production of celulignin from biomass through acid pre-hydrolysis in continuous reactor made of advanced materials such as niobium, titanium and monel. The celulignin is a fuel of 28.50 MJ/kg of heating power. The utilization of this technology together with eucalyptus reforestation by vegetative propagation and high efficiency thermoelectric plant (triple cycle of steam turbine, gas turbine and MHD electrical generation) allow electric power production with competitive cost when compared to hydroelectric power. (author). 1 ref. 5 figs., 2 tabs

1990-12-31

270

A self-tuning power system stabilizer based on artificial neural network  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a systematic approach for designing a self-tuning power system stabilizer (PSS) based on artificial neural network (ANN). An ANN is used for self-tuning the parameters of PSS in real-time. The nodes in the input layer of the ANN receive generator terminal active power (P), reactive power (Q), and voltage (V{sub t}), while the nodes in the output layer provide the optimum PSS parameters, e.g. stabilizing gain (K{sub STAB}), time constants (T{sub 1} and T{sub 2}). A new approach for the selection of number of neurons in the hidden layer has been proposed. Investigations reveal that the dynamic performance of the system with self-tuning PSS based on ANN (ST-ANNPSS) is quite robust over a wide range of loading conditions and equivalent reactance, X{sub e}. (Author)

2004-07-01

271

A new adaptive power system stabilizer using a Lyapunov design technique  

Energy Technology Data Exchange (ETDEWEB)

A technique for designing an adaptive power system stabilizer is presented which improves the dynamic stability of power systems by effectively increasing the damping torque of the synchronous generator in the system. The proposed adaptive stabilizer is optimal in the sense of minimizing a specified performance condition. A characteristic feature of using a Lyapunov techniques is that it leads to stable adaptation loops. The dynamic responses following a step disturbance by digital simulations are obtained by means of three types of stabilizers: the conventional power system stabilizer, a frequency-response-based optimal adaptive stabilizer and the proposed Lyapunov stabilizer. Simulation results on a typical single-machine/infinite-bus system illustrate the superiority of the proposed technique. (author).

1990-04-01

272

>100 watt average power at 0.53 {mu}m with 25 ns, 2.5 kHz repetition rate pulses from a single power oscillator  

Energy Technology Data Exchange (ETDEWEB)

We have generated approximately 100 watts of frequency doubled light from the output of an electro-optically Q-switched, diode-pumped Nd:YAG slab laser oscillator operating at an average power of 200 watts (2.5 kHz repetition rate, 80 mJ/pulse, 25 ns pulsewidth). The Q-switch was a compensated z-axis propagation LiNbO{sub 3} electro-optic modulator, and the frequency conversion crystal was a thin slab of KTP. In addition, Q-switched operation at an average power of approximately 250 watts with 26 ns pulsewidths has been demonstrated.

1994-03-01

273

Uncertainties in key low carbon power generation technologies - Implication for UK decarbonisation targets  

Energy Technology Data Exchange (ETDEWEB)

The UK government's economy-wide 60% carbon dioxide reduction target by 2050 requires a paradigm shift in the whole energy system. Numerous analytical studies have concluded that the power sector is a critical contributor to a low carbon energy system, and electricity generation has dominated the policy discussion on UK decarbonisation scenarios. However, range of technical, social and market challenges, combined with alternate market investment strategies mean that large scale deployment of key classes of low carbon electricity technologies is fraught with uncertainty. The UK MARKAL energy systems model has been used to investigate these long-term uncertainties in key electricity generation options. A range of power sector specific parametric sensitivities have been performed under a 'what-if' framework to provide a systematic exploration of least-cost energy system ...

2009-10-15

274

Uncertainties in key low carbon power generation technologies - Implication for UK decarbonisation targets  

International Nuclear Information System (INIS)

The UK government's economy-wide 60% carbon dioxide reduction target by 2050 requires a paradigm shift in the whole energy system. Numerous analytical studies have concluded that the power sector is a critical contributor to a low carbon energy system, and electricity generation has dominated the policy discussion on UK decarbonisation scenarios. However, range of technical, social and market challenges, combined with alternate market investment strategies mean that large scale deployment of key classes of low carbon electricity technologies is fraught with uncertainty. The UK MARKAL energy systems model has been used to investigate these long-term uncertainties in key electricity generation options. A range of power sector specific parametric sensitivities have been performed under a 'what-if' framework to provide a systematic exploration of least-cost energy system configurations under a broad, ...

2009-10-01

275

Probabilistic analysis and optimization of new power generation technologies: A case study for the externally-fired combined cycle  

Energy Technology Data Exchange (ETDEWEB)

To address the need for integrated models of advanced power generation systems and for improved analysis techniques, the US Department of Energy (DOE), through the Morgantown Energy Technology Center (METC), has supported the development of performance, emissions, and cost models of several advanced power generation systems, including integrated gasification combined cycle (IGCC), externally-fired combined cycle (EFCC) and pressurized fluidized bed combustion (PFBC) concepts. Simultaneously, numerical methods for simulation of uncertainties and optimization of process flowsheets have been implemented in the DOE`s public version of ASPEN. The new process models and computational capabilities have been applied to demonstrate the benefits of quantitative approaches to dealing with uncertainty and for optimizing technologies in the face of uncertainty. This paper focuses on modeling and assessment of the ...

1996-10-01

276

Integration of turbo-generator modules in digital transient network analyzer  

Science.gov (United States)

The behavior of a small power system consisting of two interconnected generators is simulated in real-time by a prototype Digital Transient Network Analyzer (TNA). The prototype Digital TNA consists of two Computational Modules and one I/O Module. The Modules communicate with each other through ribbon cables. Each Computational Module simulates one Turbo-Generator, its Transformer, its Governor, Exciter, and Power System Stabilizer Systems. The numerical integration is shared by two TMS320C30 DSPs at a step-size of 100 microseconds in real-time. The I/O module post-processes the state variables and presents selected information for analog display. The paper presents oscillograms from a test program which includes symmetry checks and behavioral checks against well known waveforms of hunting oscillations, synchronization out-of-phase torques, and subsynchronous resonance phenomena. The success of the ...

1994-05-01

277

Electricity generation and microbial community changes in microbial fuel cells packed with different anodic materials.  

Science.gov (United States)

Four materials, carbon felt cube (CFC), granular graphite (GG), granular activated carbon (GAC) and granular semicoke (GS) were tested as packed anodic materials to seek a potentially practical material for microbial fuel cells (MFCs). The microbial community and its correlation with the electricity generation performance of MFCs were explored. The maximum power density was found in GAC, followed by CFC, GG and GS. In GAC and CFC packed MFCs, Geobacter was the dominating genus, while Azospira was the most populous group in GG. Results further indicated that GAC was the most favorable for Geobacter adherence and growth, and the maximum power densities had positive correlation with the total biomass and the relative abundance of Geobacter, but without apparent correlation with the microbial diversity. Due to the low content of Geobacter in GS, power generated in this system may be ...

2011-09-20

278

A new efficient and simple concept for electric power generation and its thermodynamic optimization  

Energy Technology Data Exchange (ETDEWEB)

Modern combined cycle power plants with natural gas as the only fuel reach efficiencies of up to 55% for electric power generation. Nevertheless the reserve of natural gas is more limited compared to the reserve of coal. Therefore possibilities should be investigated to use coal for such plants also. One concept, that combines the use of coal in a combined cycle application with high efficiencies is examined in this paper. According to this concept the exhaust gas of the gas turbine (vitiated air) is the combustion air for the pulverized coal combustion, that takes place in the bottoming steam generator. Due to the low oxygen content of the vitiated air the burnout of the coal may be incomplete. In order to avoid the incomplete combustion of the coal and the resulting decrease of the efficiency of the plant and possible emission problems, a catalyst, that converts carbon monoxide and unburnt carbon to ...

1994-12-31

279

Design and integration of a solar AMTEC power system with an advanced global positioning satellite  

Energy Technology Data Exchange (ETDEWEB)

A 1,200-W solar AMTEC (alkali metal thermal-to-electric conversion) power system concept was developed and integrated with an advanced global positioning system (GPS) satellite. The critical integration issues for the SAMTEC with the GPS subsystems included (1) packaging within the Delta 2 launch vehicle envelope, (2) deployment and start-up operations for the SAMTEC, (3) SAMTEC operation during all mission phases, (4) satellite field of view restrictions with satellite operations, and (5) effect of the SAMTEC requirements on other satellite subsystems. The SAMTEC power system was compared with a conventional planar solar array/battery power system to assess the differences in system weight, size, and operations. Features of the design include the use of an advanced multitube, vapor anode AMTEC cell design with 24% conversion efficiency, and a direct solar insolation receiver design with integral LiF salt canisters for ...

1996-12-31

280

Forecasting for utility-scale wind farms. The power model challenge  

Energy Technology Data Exchange (ETDEWEB)

As the penetration of wind energy continues to increase around the world, with a trend towards large utility-scale wind farms (greater than 100 MW), effective wind energy forecasting will become increasingly important. Previous work by GH has estimated the trading benefit of high quality short-term forecasting to be EUR 7/MWh. Depending on market conditions, for a 100 MW wind farm with a capacity factor of 30%, this equates to an estimated annual trading benefit of up to EUR 1.8m. To date, a number of studies have focused on the mathematical modelling techniques for forecasting the production from wind farms, looking predominantly at the task of predicting the meteorological conditions at the site. This paper focuses on the final stage of the forecasting process, conversion from a meteorological forecast to a power production forecast. This challenge is particularly significant for utility-scale wind farms. The main body of research in short-term forecasting in ...

2008-07-01

281

Analysis and design of an ultra-high-temperature, hydrogen-fueled MHD generator as an open cycle power supply  

Energy Technology Data Exchange (ETDEWEB)

The theoretical analysis of a partially-ionized hydrogen gas flow (gas temperatures of approximately 10,000 to 20,000 K) through a particular class of magnetohydrodynamic (MHD) generators and the preliminary design of these MHD generators as open cycle, electric power supplies are performed. Analysis of the gas flow through these ultra-high temperature MHD generators requires a coupled gas dynamics/radiative heat transfer solution. Gas dynamics are modeled by a set of quasi-one-dimensional, nonlinear differential equations which account for friction, convective and radiative heat transfer and the interaction between the ionized gas and applied magnetic field. Radiative heat transfer is modeled using non-gray, absorbing-emitting two- and three-dimensional P-1 approximations which permit an arbitrary variation of the spectral absorption coefficient with frequency. Gas dynamics and radiative heat transfer ...

1990-01-01

282

Electric power monthly: October 1995, with data for July 1995  

Energy Technology Data Exchange (ETDEWEB)

The Electric Power Monthly (EPM) presents monthly electricity statistics for a wide audience including Congress, Federal and State agencies, the electric utility industry, and the general public. The purpose of this publication is to provide energy decisionmakers with accurate and timely information that may be used in forming various perspectives on electric issues that lie ahead. The Coal and Electric Data and Renewables Division; Office of Coal, Nuclear, Electric and Alternate Fuels, Energy Information Administration (EIA), Department of Energy prepares the EPM. This publication provides monthly statistics at the State, Census division, and US levels for net generation, fossil fuel consumption and stocks, quantity and quality of fossil fuels, cost of fossil fuels, electricity sales, revenue, and average revenue per kilowatthour of electricity sold. Data on net generation, fuel consumption, fuel stocks, quantity and cost ...

1995-10-19

283

Electric power monthly, December 1997 with data for September 1997  

Energy Technology Data Exchange (ETDEWEB)

The Electric Power Monthly (EPM) presents monthly electricity statistics for a wide audience including congress, Federal and State agencies, the electric utility industry, and the general public. The purpose of this publication is to provide energy decisionmakers with accurate and timely information that may be used in forming various perspectives on electric issues that lie ahead. This publication provides monthly statistics at the State, Census division, and US levels for net generation, fossil fuel consumption and stocks, quantity and quality of fossil fuels, cost of fossil fuels, electricity retail sales, associated revenue, and average revenue per kilowatthour of electricity sold. In addition, data on net generation, fuel consumption, fuel stocks, quantity and cost of fossil fuels are also displayed for the North American Electric Reliability Council (NERC) regions. The EIA publishes statistics in the EPM on net ...

1997-12-01

284

Understanding and protecting steam generator materials  

Science.gov (United States)

Solid solution-strengthened nickel base alloys have been used for nuclear stream generator tubing in pressurized water reactors since the beginnings of commercial nuclear power. The purpose of this paper is to recap and update the authors understanding of the relationship between processing, resulting structure, and properties for Alloy 600 and to discuss the requirements for optimized performance in both primary and secondary environments. Potential replacement materials and their performance will be discussed. Also discussed is the role and importance of system chemistry, bulk and local, and control and its relationship to performance. A discussion of potential mechanisms of environmentally assisted failure is also discussed.

1986-01-01

285

Understanding and protecting steam generator materials  

International Nuclear Information System (INIS)

Solid solution-strengthened nickel base alloys have been used for nuclear stream generator tubing in pressurized water reactors since the beginnings of commercial nuclear power. The purpose of this paper is to recap and update the authors understanding of the relationship between processing, resulting structure, and properties for Alloy 600 and to discuss the requirements for optimized performance in both primary and secondary environments. Potential replacement materials and their performance will be discussed. Also discussed is the role and importance of system chemistry, bulk and local, and control and its relationship to performance. A discussion of potential mechanisms of environmentally assisted failure is also discussed.

1986-11-16

286

The solution to avoid protection fuses' failure of the driving motor of the turbine-generator set during its startup in Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

Based on a detailed analysis of the inter-relationship in the current, voltage, electromagnetic torque and ratio of the difference between the speed of rotor and the speed of rotary magnetic field to the later in the motor, the root cause was point out, which leads to the protection fuses' failure of the motor in the starting stage, which drives the turbine-generator set to rotate at low speed before its startup. Two solutions to avoid the situation are proposed, too. (authors)

2005-09-01

287

Steam generator tube performance  

International Nuclear Information System (INIS)

A review of the performance of steam generator tubes in 116 water-cooled nuclear power reactors showed that tubes were plugged at 54 (46 percent) of the reactors. The number of tubes removed from service decreased from 4 692 (0.30 percent) in 1981 to 3 222 (0.20 percent) in 1982. The leading causes of tube failures were stress corrosion cracking from the primary side, stress corrosion cracking (or intergranular attack) from the secondary side and pitting corrosion. The lowest incidence of corrosion-induced defects from the secondary side occurred in reactors that have used only volatile treatment, with or without condensate demineralization.

2005-10-27

288

Seconds capacity reserve and heat consumption with different operating procedures of steam turbines. Sekundenleistungsreserve und Waermeverbrauch bei verschiedenen Betriebsarten von Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

In order to ensure a power balance in an electrical network a spinning reserve has to be capable of activation within seconds. However, because of the need to vary the fuel flow in the steam generator, the run-up of output takes minutes. The required capacity response is therefore achieved by storage of steam from the steam generator. In this process the turbine control valves come into action in a specific manner. The paper describes the importance of the initial reserve for unit capacity control. (orig.).

1989-09-01

289

Generation of high-energy electrons and ions at propagation of relativistic laser pulses through supercritical plasma  

International Nuclear Information System (INIS)

In terms of the kinetic theory of the interaction between the high-power short-time laser pulses with plasma based on the propagator plotting for the plasma particle distribution functions one studied the generation of the hot electrons and of the fast ions as the relativistic femtosecond laser pulses travelled through the supercritical density plasma. One performed calculations based on the various values of the laser pulse intensity, types of the multiple-charged ions, the plasma inhomogeneity degree. One studied the acceleration mechanisms both of the plasma electrons and ions

2007-12-01

290

Effect of secondary circuit materials and water regime on steam generator reliability  

International Nuclear Information System (INIS)

The mechanism of the salt concentration increase in pits and crevices formed in a steam generator due to its imperfect manufacture or to its design features is described. The probability of corrosion can be reduced by choosing a suitable steel and by securing low concentrations of salts (chlorides in particular) and corrosion products in the feedwater. Attention is paid to the distribution of salts in the water-steam circuit and to the conditions of erosion corrosion as the principal source of corrosion products in feedwater. Experience with the suppression of erosion corrosion at nuclear power plants abroad is described. (E.J.).

1989-05-01

291

Development of a polymer fuel cell system for naval surface ship applications  

Energy Technology Data Exchange (ETDEWEB)

In the framework of the development of new generations of surface ships, the Royal Netherlands Navy is studying the option of the all-electric ship concept. Background is the growing demand of electric power on board of naval ships for various services (including weapons and sensors). Important features of such an all-electric ship concept are decentralized electric energy generation and storage. In such an all-electric ship concept, fuel cells are expected to play an important role in the future, not only for reasons of energy efficiency and low emissions, but also because of their potential military advantages. Especially polymer electrolyte fuel cell systems appear to be very interesting for this application.

1996-12-31

292

A review of the behaviour of alloy 800 in liquid sodium  

International Nuclear Information System (INIS)

Although there is service experience of Alloy 800 as tubing for superheaters in conventional and nuclear (HTR) power stations and in PWR heat exchangers, there is no corresponding service experience in sodium-cooled fast reactor steam generators. However, some limited experimental studies have been made of corrosion behaviour, and of possible structure modifications and effects on mechanical properties which occur during exposure of this material to a high temperature sodium environment, and these are summarised in the paper. It is concluded that further work needs to be done before Alloy 800 can be confidently endorsed for use as tubing in fast reactor steam generators. (author).

293

The Effect of Fuel Price on the Economic Analysis of Hybrid (Photovoltaic/Diesel/Battery) Systems in Iran  

British Library Electronic Table of Contents (United Kingdom)

Diesel power technology has been utilized worldwide, especially in remote regions, because of its low initial capital cost. But it has negative effects on the surrounding environment and causes global warming. On the other hand, depleting oil and fuel resources has made it inevitable to seek alternative/renewable energy resources. In Iran, the cost of fuel is highly subsidized. If Iran removes the fuel subsidy, the cost of diesel fuel would increase and the photovoltaic (PV) or hybrid PV/diesel systems would become more attractive. Hybrid photovoltaic/diesel/battery (PV/diesel/bat) systems which use PV energy, combined with diesel generation power and battery bank storage are an excellent solution to decrease diesel generator costs, pollution, and electrification of remote rural areas. In ...

2011-01-01

294

Steam generator tube performance: experience with water-cooled nuclear power reactors during 1979  

International Nuclear Information System (INIS)

The performance of steam generator tubes in water-cooled nuclear power reactors has been reviewed for 1979. Tube failures occurred at 38 of the 93 reactors surveyed. Causes of these failures and procedures designed to deal with them are described. The defect rate was twice that in 1978 but still lower than the two previous years. Methods being employed to detect defects include increasing use of multifrequency eddy-current testing and a trend to full-length inspection of all tubes. To reduce the incidence of tube failures by corrosion, plant operators are turning to full-flow condensate demineralization and more leak-resistant condenser tubes. (author).

1994-10-18

295

SOLID OXIDE FUEL CELL HYBRID SYSTEM FOR DISTRIBUTED POWER GENERATION  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the work performed by Honeywell during the October 2001 to December 2001 reporting period under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL) entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. The main objective of this project is to develop and demonstrate the feasibility of a highly efficient hybrid system integrating a planar Solid Oxide Fuel Cell (SOFC) and a turbogenerator. The conceptual and demonstration system designs were proposed and analyzed, and these systems have been modeled in Aspen Plus. Work has also started on the assembly of dynamic component models and the development of the top-level controls requirements for the system. SOFC stacks have been fabricated and performance mapping initiated.

2003-08-01

296

Reliability data update method for emergency diesel generator of Daya Bay Nuclear Power Plant  

British Library Electronic Table of Contents (United Kingdom)

In the field of Living Probabilistic Safety Assessment (LPSA) the reliability data updating is an important factor. In risk analysis equipment failure data is needed to estimate the frequencies of events contributing to risk posed by a facility. Five years data of emergency diesel generator (EDG) of Daya Bay Nuclear Power Plant (NPP) has been studied in this paper. The data updating process has been done by using two methods, i.e., the classical method and Bayesian method. The aim of using these methods is to calculate the operational failure rate (@l) and demand failure probability (p). The results show that the operational failure rate is 1.7E-3 per hour and the demand failure probability is 2.4E-2 demand per day for Daya Bay NPP. By comparing the results obtain from classical and Bayesi...

2011-01-01

297

PSPs at Bhira and Bhivpuri  

International Nuclear Information System (INIS)

Tata Electric Companies (TEC) are engaged in the generation of hydro and thermal energy. TEC, to minimise backing down of its thermal units in off peak hours and also to at least partially meet the growing deficit in the supply during peak hours is moving to install pumped storage plants (PSPs) utilising off-peak surplus energy for pumping the water from lower pond to the upper pond for subsequent utilisation for power generation during peak hours. In view of some of the infra structural facilities such as storage ponds, water conductor system, transmission lines, etc. being already available, at the existing hydro power stations owned by TEC, the pumped storage units are being proposed within the environs of existing hydro stations, i.e. a 150 MW pumped storage unit at Bhira and a 90 MW pumped storage unit at Bhivpuri. The projects are described and cost estimates is given. (author). 2 figs.

1992-01-01

298

Laser-generated PuO_2--UO_2 condensation aerosols  

International Nuclear Information System (INIS)

A 340-watt CO_2 laser is being used to generate PuO_2-UO_2 condensation aerosol from the surface of a Liquid Metal Fast Breeder Reactor (LMFBR) fuel pellet. A wide range of concentrations is achieved by varying the laser power, pulse width, and/or pulse period. The resulting aerosol is composed of branch chain-like aggregates, with the primary particle size ranging between 0.005 and 0.15 #mu#m. X-ray diffraction analyses show that these aerosols condense into a face-centered cubic crystal structure. The activity mean aerodynamic diameter (AMAD), for most power levels, is approximately 0.85 #mu#m with a geometric standard deviation of 1.5.

1977-05-01

299

IEEE standard quality assurance program requirements for the design and manufacture of class 1E instrumentation and electric equipment for nuclear power generating station  

International Nuclear Information System (INIS)

The Institute of Electrical and Electronic Engineers (IEEE) standards for the quality assurance requirements for the design and manufacture of Class 1E instrumentation and electric equipment for a nuclear power generating station are presented. This standard establishes Quality Assurance Program requirements for electrical manufacturers. This standard, used in conjunction with ANSI N45.2-1977 and the supplemental standards to the extent referenced in this standard, is intended to meet the requirements of 10CFR50, Appendix B. These requirements are intended to assure that Class 1E instrumentation and electric equipment are responsibly engineered and manufactured from proper materials, that the manufacturing processes and practices are controlled, and that the manufacturing process produces a product of the required quality for Class 1E application.

300

High efficiency chemical energy conversion system based on a methane catalytic decomposition reaction and two fuel cells: Part I. Process modeling and validation  

British Library Electronic Table of Contents (United Kingdom)

A highly efficient integrated energy conversion system is built based on a methane catalytic decomposition reactor (MCDR) together with a direct carbon fuel cell (DCFC) and an internal reforming solid oxide fuel cell (IRSOFC). In the MCDR, methane is decomposed to pure carbon and hydrogen. Carbon is used as the fuel of DCFC to generate power and produce pure carbon dioxide. The hydrogen and unconverted methane are used as the fuel in the IRSOFC. A gas turbine cycle is also used to produce more power output from the thermal energy generated in the IRSOFC. The output performance and efficiency of both the DCFC and IRSOFC are investigated and compared by development of exact models of them. It is found that this system has a unique loading flexibility due to the good high-loading property of ...

2010-01-01

301

Gas and steam turbines: Power from fire; Gas- und Dampfturbinen: Kraft aus dem Feuer  

Energy Technology Data Exchange (ETDEWEB)

More than 200 years after the birth of the steam engine, the first thermal engine ever invented, thermal engines such as steam turbines, gas turbines or internal combustion engines are still driving most generators for electric power generation, most machines, and most vehicles, and this will remain so until far into the next century. (orig.) [Deutsch] Mit Waermekraftmaschinen wie Dampfturbinen, Gasturinen und Verbrennungsmotoren werden auch heute - mehr als 200 Jahre nach der technischen Reife der Dampfmaschine (der ersten Waermekraftmaschine) - die meisten Generatoren zur Stromerzeugung, die meisten Arbeitsmaschinen und die meisten Fahrzeuge angetrieben. Und dabei wird es auch bis weit in das 21. Jahrhundert bleiben. (orig.)

1996-02-01

302

Experimental demonstration of a trumpet secondary concentrator for the Cummins Power Generation (CPG) 7.5 kW(e) dish-Stirling system  

Energy Technology Data Exchange (ETDEWEB)

A prototype trumpet type nonimaging secondary concentrator has been designed and fabricated for use with the Cummins Power Generation (CPG) 7.5 kW(e) dish-Stirling system and a preliminary set of operating tests has been carried out. The secondary is 26.7 cm (10.5 in.) deep by about 69 cm (27 in.) wide, and has a geometric concentration of 1.7X. The test units were fabricated from polished copper spinnings, overcoated with vapor deposited aluminum and aluminum oxide layers and are water cooled. The basic design considerations are reviewed, the objectives and test procedures for the experiment are summarized and some preliminary results are presented.

1996-11-01

303

Energy and nuclear power planning study for Thailand  

International Nuclear Information System (INIS)

The present report describes the study conducted in co-operation with several agencies and organizations from Thailand and covers the energy and electricity requirements and the optimal expansion plans for the power generating system for this country up to year 2011. It is emphasized that the study was carried out by a team of experts from the Electricity Generating Authority of Thailand (EGAT), the National Economic and Social Development Board (NESDB), the National Energy Administration (NEA) and the Office of Atomic Energy for Peace (OAEP), who were fully responsible for all phases of the study, including the production of the present report. The IAEA's responsibility was to provide overall co-ordination and general guidance during the conduct of the study, as well as training and assistance in the implementation and use of the IAEA's computerized planning methodologies on the computer facilities of Thailand. Refs, figs ...

2002-06-16

304

Eddy currents signal processing for steam generator inspection in PWR nuclear power plants  

International Nuclear Information System (INIS)

Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostic system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of these items.

1992-01-01

305

Development of a portable thermophotovoltaic power generator  

Energy Technology Data Exchange (ETDEWEB)

A 150 Watt thermophotovoltaic (TPV) power generator is being developed. The technical approach taken in the design focused on optimizing the integrated performance of the primary subsystems in order to yield high energy conversion efficiency and cost effectiveness. An important aspect of the approach is the use of a selective emitter radiating to a bandgap matched photovoltaic array to minimize thermal and optical recuperation requirements, as well as the non-recoverable heat losses. For the initial prototype system, fibrous ytterbia emitters radiating in a band centered at 980 nm are matched with high efficiency silicon photoconverters. The integrated system includes a dielectric stack filter for optical energy recovery and a ceramic recuperator for thermal energy recovery. The system has been operated with air preheat temperatures up to 1350K. The design of the system and development status are presented. {copyright} {ital 1997 American ...

1997-03-01

306

Corrosion behavior of iron and nickel base alloys in high temperature and pressure water  

International Nuclear Information System (INIS)

In equipment industries, the equipments handling industrial water and pure water are numerous. In power generation including nuclear power generation, water serves as a working medium. Review is made on the experiences in the corrosion of iron and nickel base alloys in high temperature, high pressure water and the results of researches derived from them. Under high temperature and high pressure, carbon steel, low alloy steel, stainless steel and high nickel alloy cause corrosion even in pure water. But in the case of serious corrosion, chlorine, oxygen, alkali and others in water take part. The following matters are described: corrosion by steam; stress corrosion cracking in pure water; corrosion by impurities in high temperature, high pressure pure water, i.e. chlorine ions, dissolved oxygen, and alkali; corrosion under radiation. (J.P.N.).

307

Clean combustion of solid fuels  

International Nuclear Information System (INIS)

A chemical-looping process is proposed for the clean combustion of solid fuels for electric power or heat generation. The process is based on coal gasification with CO_2 to produce CO. The CO then reduces CaSO_4, which is used as an oxygen carrier, in a separate reactor to give CaS and CO_2. A portion of the CO_2 is recycled for the gasification stage and the rest can be sent for sequestration. The CaS is sent to another reactor for oxidation with air and to generate heat or power. The overall thermal effect is the same as direct combustion, but separation of CO_2 and other pollutants, such as sulphur, is achieved. In comparison with conventional chemical-looping combustion of natural gas, much less water is present in the CO_2 product, and hence the loss of heat energy and corrosion of the fuel-reactor system can be reduced.

2008-01-01

308

Catalytic hot gas conditioning of biomass derived product gas  

Energy Technology Data Exchange (ETDEWEB)

Biomass gasification provides the potential to efficiently and economically produce a renewable source of a clean gaseous fuel suitable for power generation or synthesis gas (syngas) applications. An important side benefit of the use of biomass is the effective minimization of the primary greenhouse gas, carbon dioxide (CO{sub 2}), by providing a means to close-loop the CO{sub 2} cycle. However, high molecular weight hydrocarbon constituents (tar) in the product gas from gasification can complicate the downstream uses of the gas. This paper discusses both the development of a low cost, disposable catalyst system that can eliminate these heavy hydrocarbons from the gas and the use of the catalyst in conjunction with the Battelle high-throughput gasification process for power generation and synthesis applications. (author)

1997-12-31

309

Cardiac Pacing: Memories of a Bygone Era  

British Library Electronic Table of Contents (United Kingdom)

The first cardiac pacemaker implants occurred in the late 1950s and involved insertion of epicardial or epimyocardial leads and abdominal pulse generators. By the mid 1960s, cardiologists were making attempts to insert transvenous leads into the right ventricle. These early unipolar leads had large, polished, high polarization electrodes, no fixation device, and no lumen in which to place a stylet for lead positioning. The lead implantation procedures were usually long and the irradiation to both patient and operator excessive. Pulse generators were powered by zinc-mercury cells, which were large, unreliable, and prone to sudden output failure. Postoperative complications such as lead dislodgement, exit block, and premature power source failure were very common with most patients requiring...

2008-01-01

310

Wood-gas / natural-gas combined-cycle power station for Switzerland - Potential and estimation of financial viability; Holzgas/Erdgas-Kombikraftwerk fuer die Schweiz: Potenzial und Wirtschaftlichkeitsabschaetzung. Input-Papier fuer die Stromangebots-Perspektiven 2035 des Bundesamts fuer Energie  

Energy Technology Data Exchange (ETDEWEB)

This paper was produced as an input to the Swiss Confederation's 'Electricity Perspectives 2035' study made by the Swiss Federal Office of Energy (SFOE). A concept for the combined use of wood and natural gas in a combined-cycle power station is presented. The gasification of wood to provide fuel for the gas turbines and waste-heat boilers of such power stations is proposed as an alternative to just burning wood to provide heat for steam generators. Figures are quoted on the quantities of biomass and wood usable for energy applications in Switzerland. The energetic and financial efficiencies of wood-powered generation of heat and electricity are examined, as are the investments necessary and the costs incurred. Comparisons are presented between wood from forests, sawmill-wastes, scrap wood and natural gas as fuels.

2005-07-01

311

Use of selective catalytic reduction for control of NO{sub x} emissions from power plants  

Energy Technology Data Exchange (ETDEWEB)

This report describes selective catalytic reduction (SCR) technologies which offer an economical and effective means of reducing nitrogen oxide emissions from electricity generation facilities and reviews the feasibility and cost effectiveness of employing this technology on electricity generating facilities in Ontario. Based on experiences in the United States, in British Columbia, and internationally in Japan and Germany, the indication is that the technology for the installation of SCR systems on new gas-fired combined cycle power plants and existing coal-fired power plants has grown enormously during the past decade, and has been established as the control technology of choice for nitrogen oxide emissions. It is widely acknowledged to reduce power plant nitrogen oxide emissions, and do so at a very reasonable incremental cost. It is estimated that the annualized cost of ...

1999-07-01

312

Simulation for transient stability study of the Taiwan power system - a nuclear majority system  

Energy Technology Data Exchange (ETDEWEB)

A transient stability program was developed for the Taiwan Power Company, which has a high proportion of nuclear generation in its power system. This program offers a new territory to investigate nuclear plant effects on the power system transient stability. This program also provides a high speed tool for the Taipower system operational planning. A generalized procedure of synchronous machine modeling for a large-scale stability study is presented. The merits and weaknesses of machine modeling can be comprehended through each item of this procedure. Three types of nonlinear synchronous machine modeling implemented into this stability program are derived by following this procedure. A robust subroutine was derived to perform the fourth order Runge-Kutta integration method, making the software programming neat and systematical. For simulating the nuclear plant influence on the system, this program ...

1984-01-01

313

Simulation for transient stability study of the Taiwan power system - a nuclear majority system  

International Nuclear Information System (INIS)

A transient stability program was developed for the Taiwan Power Company, which has a high proportion of nuclear generation in its power system. This program offers a new territory to investigate nuclear plant effects on the power system transient stability. This program also provides a high speed tool for the Taipower system operational planning. A generalized procedure of synchronous machine modeling for a large-scale stability study is presented. The merits and weaknesses of machine modeling can be comprehended through each item of this procedure. Three types of nonlinear synchronous machine modeling implemented into this stability program are derived by following this procedure. A robust subroutine was derived to perform the fourth order Runge-Kutta integration method, making the software programming neat and systematical. For simulating the nuclear plant influence on the system, this program ...

314

Optimizing power plant cycling operations while reducing generating plant damage and costs  

Energy Technology Data Exchange (ETDEWEB)

This presentation describes a method for analyzing, quantifying, and minimizing the total cost of fossil, combined cycle, and pumped hydro power plant cycling operation. The method has been developed, refined, and applied during engineering studies at some 160 units in the United States and 8 units at the Irish Electric Supply Board (ESB) generating system. The basic premise of these studies was that utilities are underestimating the cost of cycling operation. The studies showed that the cost of cycling conventional boiler/turbine fossil power plants can range from between $2,500 and $500,000 per start-stop cycle. It was found that utilities typically estimate these costs by factors of 3 to 30 below actual costs and, thus, often significantly underestimate their true cycling costs. Knowledge of the actual, or total, cost of cycling will reduce power production costs by enabling utilities to more ...

1998-12-31

315

New era for coal-based electricity generation in the United States  

Energy Technology Data Exchange (ETDEWEB)

In 1970, the Federal Power Commission predicted a fall from 46% to 27% in 1990 as a result of predicted increases in the use of nuclear power. Today, the Department of Energy expects coal to supply about 50% of electricity generation in 1990. About one-eighth of the world's annual hard coal production is used to make electricity in the United States. Power stations in the country used more coal in 1979 than was produced in the whole Western Europe that year. These 405,000,000 tons of coal equivalent were burned in 1257 individual utilities with an aggregate capacity of 235,000 megawatts. There are coal-fired power plants in 43 of the 50 states. Four factors will be most important in shaping the future development of coal-based electricity: prices, conservation, environmental regulations, and national security. The price differential between coal and oil has now reached a ...

1980-01-01

316

Conceptual design of the Fast-Liner Reactor (FLR) for fusion power  

International Nuclear Information System (INIS)

The generation of fusion power from the Fast-Liner Reactor (FLR) concept envisages the implosion of a thin (3-mm) metallic cylinder (0.2-m radius by 0.2-m length) onto a preinjected plasma. This plasma would be heated to thermonuclear temperatures by adiabatic compression, pressure confinement would be provided by the liner inertia, and thermal insulation of the wall-confined plasma would be established by an embedded azimuthal magnetic field. A 2- to 3-mu s burn would follow the approx. 10"4 m/s radial implosion and would result in a thermonuclear yield equal to 10 to 15 times the energy initially invested into the liner kinetic energy. For implosions occurring once every 10 s a gross thermal power of 430 MWt would be generated. The results of a comprehensive systems study of both physics and technology (economics) optima are presented. Despite unresolved problems associated with both the physics and ...

317

Roof slab cooling device in a FBR type reactor  

International Nuclear Information System (INIS)

Purpose: To obtain a roof slab cooling device capable of retaining cooling performance even in a case of electric power supply stop or failure and effective from economical point of view. Constitution: Atmospheric air is introduced into the cooling chamber of a proof slab and spontaneously passed to a exit pipeway connected to a stack thereby cooling the roof slab. Specifically, atmospheric air entered from the inlet pipeway is introduced to the cooling chamber and absorbs heat generate from the inside of the reactor container. Warmed air is sucked from the exit pipeway and then released into the atmosphere passing through the stack. The air cools the roof slab during circulation due to spontaneous passage and keeps the slab at a low temperature. Since the air is passed spontaneously, no power such as for a blower is required at all and, if the electric power supply should be lost, the cooling ...

1986-05-16

318

PWM applications for the electric railway traction system fed by the AC/DC dual power line  

Energy Technology Data Exchange (ETDEWEB)

The latest electronic circuit technology that can be used for the electric railway traction system fed by an AC/DC dual power line was developed. This system consists of reverse conducting GTO thyristors, microprocessors, and DSP`s. In the AC power supply line section, the line converter is controlled by PWM technology to secure a high power factor and reduce the higher harmonic generation of an input current as far as possible. The line converter and motor converter use reverse conducting GTO thyristors. Since these converters are cooled using a heat pipe cooler, they are reduced in size and weight. The electric grounding point of the main power circuit is set to the negative side of the DC line for AC and DC line sections. Therefore, the AC/DC selector switch was simplified in structure. Moreover, the DC input for the auxiliary power supply can be obtained ...

1996-01-01

319

The challenge of implementing an IRP process in Asia: The case of Hainan Province, China  

Energy Technology Data Exchange (ETDEWEB)

Developing a modern electric power sector is necessary for economic growth and development to proceed. Institutions to implement an IRP (integrated resource planning) process do not exist in many countries. Hainan`s economy is growing rapidly with a concomitant increase in electricity demand. This is an ideal time in Hainan`s development to implement an IRP process. The challenge is for Hainan to develop institutions and incentive mechanisms for HEPCO (Hainan Electric Power Co.) to adopt cost-based pricing, run DSM programs, construct renewable generating plants, etc. One proposal is to great a Hainan government-wide IRP committee.

1994-12-31

320

Small power production case study: Montello hydroelectric plant, Montello, Wisconsin  

Energy Technology Data Exchange (ETDEWEB)

A case study of a small-scale hydroelectric plant to identify implementation problems is presented. The Montello hydroelectric plant is described including the background and history of the plant, the physical characteristics, the financial history and costs, operation, regulatory agencies, and the problems encountered in its operation. The analyses of the energy and capacity (demand) credits for the Montello hydroelectric plant when it is added to the Wisconsin Power and Light Company generating system is described. The WP and L base case and the results of the analyses are discussed. (WHK)

1980-11-01

321

Protective oxides in coal-fired combined cycle power systems  

Energy Technology Data Exchange (ETDEWEB)

In most industrial processes operating at elevated temperatures, protective oxide layers perform a vital duty in protecting the underlying metallic alloys from process gases. Coal-fired combined cycle power generation systems present a number of process conditions in which the properties of the protective oxide layers are particularly important. This paper discusses two of these particular conditions: (1) `erosion/corrosion` of in-bed heat exchanger tubing and (2) thermal cycling of hot gas path components. For both these situations, the desirable properties of protective scales are outlined. The behaviour of scales in practice are highlighted. 33 refs., 6 figs., 2 tabs.

1995-12-31

322

Marketing opportunity for industries/power plants -- the Swedish case  

Energy Technology Data Exchange (ETDEWEB)

This paper describes and analyses the new situation in the electricity market in Sweden and the attendant emergence of a unique marketing opportunity for industries and power plants to capitalize on bioenergy. This recent marketing opportunity, which is based on consumer demand, has come about through a number of recent institutional changes in Sweden that have drastically lowered the transaction costs associated with the purchase of green electricity, i.e. electricity generated in what is classified as an environmentally sound manner. This has created a functioning market for green electricity and products made using green electricity.

1996-12-31

323

International Water Power and Dam Construction Handbook 1993  

Energy Technology Data Exchange (ETDEWEB)

In this handbook, technical reports on a number of hydro plants under construction are provided. In addition tables of compiled data are presented on a world-wide basis for the following: turbine and hydro generator contracts; hydropower resource potential and development; pumped storage plants; the major dams and hydro plants; roller compacted concrete dams and concrete faced rockfill dams; small hydropower. An address database of international organizations of relevance to hydropower development, national power authorities and nation committees of the International Commission an Large Dams is included. A final and major section of the handbook is a buyer's guide providing extensive company data and information on products and services. (UK)

1993-01-01

324

Innovative Design of New Geothermal Generating Plants  

Energy Technology Data Exchange (ETDEWEB)

This very significant and useful report assessed state-of-the-art geothermal technologies. The findings presented in this report are the result of site visits and interviews with plant owners and operators, representatives of major financial institutions, utilities involved with geothermal power purchases and/or wheeling. Information so obtained was supported by literature research and data supplied by engineering firms who have been involved with designing and/or construction of a majority of the plants visited. The interviews were conducted by representatives of the Bonneville Power Administration, the Washington State Energy Office, and the Oregon Department of Energy during the period 1986-1989. [DJE-2005

1989-07-01

325

Feasibility of dual-fuel engine block concept in large cogeneration plants  

Energy Technology Data Exchange (ETDEWEB)

Fairbanks Morse Engine Division of Coltec Industries is ready to move into the cogeneration market with its well established engine program. Over the past six years the company has been refining and improving both the 38D8-1/8 opposed piston and PC2.5 dual-fuel engines in several areas. The most important targets achieved are higher power output, lower exhaust emissions, better fuel economy, better maintainability and longer life. The result is the Enviro-Design series of engines which the company believes will find broad application in the power generation and cogeneration fields. 3 figs.

1993-06-01

326

An algorithm for scheduling a large pumped storage plant  

Energy Technology Data Exchange (ETDEWEB)

The Michigan Electric Coordination Center (MEPCC), operated by Consumers Power and Detroit Edison Companies, has the responsibility for scheduling the Ludington pumped storage plant. Ludington has an extremely large economic effect on the Consumers Power and Detroit Edison Companies' system due to its size (over 1800 MW net demonstrated generating capability). This paper presents a dynamic programming algorithm for scheduling large pumped storage plants and shows how this method can be coordinated with the commitment of the thermal units of the system.

1985-08-01

327

Outline of design and construction of civil engineering work for Higashi-Niigata thermoelectric power station No.4 system; Higashiniigata karyoku hatsudensho yongo keiretsu doboku koji no sekkei to seko no gaiyo  

Energy Technology Data Exchange (ETDEWEB)

Tohoku Electric Power Co., Ltd., is now building an LNG-fired No. 4 System (combined cycle of 1.61-million kW) for its Higashi Niigata Thermoelectric Power Station sited in the Niigata East Harbor industrial zone. This is a unit that aims at a thermal efficiency of 50% first in the world by using high-efficiency gas turbines, etc. After the completion of the No. 4 System, the station (No. 1 Machine, No. 2 Machine; No. 3 System, No. 4 System; Harbor No. 1 Machine, Harbor No. 2 Machine) will be generating a total power of 4.6kW, providing the company with its maximum power source which ranks among the largest-grade thermoelectric power stations in this country. Since the construction work was started in April, 1996, approximately 40% had been completed as of March-end, 1997, including foundations for the power station main building, stack, ...

1997-07-05

328

Geothermal power plant R and D: an analysis of cost-performance tradeoffs and the Heber Binary-Cycle Demonstration Project  

Energy Technology Data Exchange (ETDEWEB)

A study of advancements in power plant designs for use at geothermal resources in the low to moderate (300 to 400F) temperature range is reported. In 3 case studies, the benefits of R and D to achieve these advancements are evaluated in terms of expected increases in installed geothermal generating capacity over the next 2 decades. A parametric sensitivity study is discussed which analyzes differential power development for combinations of power plant efficiency and capitol cost. Affordable tradeoffs between plant performance and capital costs are illustrated. The independent review and analysis of the expected costs of construction, operation and maintenance of the Heber Binary Cycle Geothermal Power Demonstration Plant are described. Included in this assessment is an analysis of each of the major cost components of the project, including (1) construction cost, (2) well field ...

1983-06-30

329

Future radioisotope power needs for missions to the solar system  

Energy Technology Data Exchange (ETDEWEB)

NASA and DOE plan a cooperative team effort with industry, government laboratories and universities to develop a near term, low cost, low power (100 watt electric class), low mass (<10 kg), advanced radioisotope space power source (ARPS) and in the process reduce the plutonium-related costs as well. The near term is focused on developing an advanced energy converter to use with the General Purpose Heat Source (GPHS). The GPHS was developed and used for the current radioisotope thermoelectric generators (RTGs). Advanced energy converter technologies are needed as a more efficient replacement for the existing thermoelectric converters so that the space radioisotope power source mass and cost can be reduced. a more advanced technology space radioisotope power system program is also planned that addresses a longer-term need. Twenty first century robotic scientific information ...

1997-12-31

330

Special features of control and protection for large saturated steam turbines  

International Nuclear Information System (INIS)

For shut-down safety of the turbine generator (securing of auxiliary power operation after load shut-down and preventing the reaching of overspeed after load shut-down with disturbed turbine governing system) additional measures compared to those for superheated steam turbines are required for turbine generators in plants with pressurized water reactor (PWR) as well as those with boiling water reactor (BWR) . Equipment is described (e.g. overspeed govern or selecting connection, vacuum breaker, bypass valves, intercepting valves) which, depending on the own conditions of the individual turbine generator (e.g. run-up time, vacuum, enclosed energy), may be applied alone or in jointly. (orig.).

331

Research on pitting corrosion of steam generator heat transfer tubes based on acoustic emission  

International Nuclear Information System (INIS)

Corrosion of steam generator heat transfer tubes (SGHTT) is one of the important problems which affect safety operation of nuclear power plants (NPP), and the hazard of pitting corrosion of heat transfer tubes is the most serious. With an acoustic emission device, the signals during a corrosion test on SGHTT were collected and analyzed, and the corrosion points in the tubes were located accurately. The results show that pitting corrosion of heat transfer tubes has passed through three periods in its development: expansion phase, stationary phase and rapid developing phase. The corrosion damage of HTT can be found earlier with acoustic emission than any other non-destructive testing methods. Acoustic emission can be used for on-line and real-time monitoring of the safety and operation of the steam generator and has therefore a great significance. (orig.)

2010-09-01

332

Evaluation of validity of the RELAP5/MOD3 flow regime map for horizontal tubes  

Energy Technology Data Exchange (ETDEWEB)

RELAP5/MOD3 code was developed for western type power water reactors with vertical steam generators. Thus, this code should be validated also for VVER design with horizontal steam generators. The validation work, which has been started in Lappeenranta University of Technology (LUT), has already shown some weaknesses of the code. For example the flow inside a steam generator horizontal tube in some accident cases is not correctly modelled by the code. It may be the result of erroneous prediction of the flow regime. The aim of the study is the attempt of verification of the flow regime map, which is used in the RELAP5/MOD3 computer code for two-phase flow in horizontal tubes. (18 refs.).

1996-12-31

333

Corrosion in steam generators of PWR type nuclear power plants  

International Nuclear Information System (INIS)

Problems are discussed of heat exchange tubes of Westinghouse type vertical steam generators exhibiting corrosion damage such as point corrosion, planar corrosion, tube denting, corrosion stress cracking, crevice corrosion, fretting corrosion and intergranular corrosion. Attention is also paid to problems of WWER-440 type horizontal steam generators, where the level fluctuation area is critical; noncompact porous deposits of the corrosion products give rise to crevice effects and cause significant concentration of chloride ions and other additions. This problem can be partly resolved by a modification of the collector design at the level variation area. An additional measure is the production of steel 08Kh18N10T with a very low level of harmful elements and inclusions. (Z.M.). 3 figs., 11 refs.

1988-03-01

334

Controlled storage for distributed power generation and optimised energy flow in low-voltage mains; Steuerbare Speicher zur Optimierung des Energieflusses in Niederspannungsnetzen mit DEA  

Energy Technology Data Exchange (ETDEWEB)

This comprehensive final report for the Swiss Federal Office of Energy (SFOE) examines ways to optimise energy flows in mains networks that include distributed generation facilities. Increasing use of decentralised generation, its effects on the operation of low-voltage mains and the efficient use of the 400 V mains is discussed. The principles of operation and construction of controlled storage installations are discussed and concrete examples of their use in both grid-connected and island operation are quoted. Alternatives to storage are looked at from both the technical and economic points of view. The storage technologies used such as flywheels, supercaps, redox-flow batteries and lead-acid accumulators are briefly assessed and the results of simulations are discussed.

2005-07-01

335

Assessing the performance and benefits of customer distributed generation developers under uncertainties  

British Library Electronic Table of Contents (United Kingdom)

In this paper, the performance of customer-owned distributed generation (DG) units is quantified from different perspectives through an uncertainty study. A Monte Carlo-based method is applied to assess the stochastic operation of the customer-owned DG units in the power distribution system. Several cases are studied to analyze the impact on system performance of using such generators, with the emphasis on benefits. The results of the studied cases show that proper operation of customer-owned DG units placed close to significant consumption centers offers several benefits which lead to significant energy savings and improvement in the performance indices while maintaining the cost-effectiveness. Furthermore, based on the energy demand, different electricity price scenarios considering a co...

2011-01-01

336

Wien Automatic System Planning (WASP) Package. A computer code for power generating system expansion planning. Version WASP-IV. User's manual  

International Nuclear Information System (INIS)

As a continuation of its efforts to provide methodologies and tools to Member States to carry out comparative assessment and analyse priority environmental issues related to the development of the electric power sector, the IAEA has completed a new version of the Wien Automatic System Planning (WASP) Package WASP-IV for carrying out power generation expansion planning taking into consideration fuel availability and environmental constraints. This manual constitutes a part of this work and aims to provide users with a guide to use effectively the new version of the model WASP-IV. WASP was originally developed in 1972 by the Tennessee Valley Authority and the Oak Ridge National Laboratory in the USA to meet the IAEA needs to analyse the economic competitiveness of nuclear power in comparison to other generation expansion alternatives for supplying the future electricity requirements ...

1997-12-01

337

The automatic programming for safety-critical software in nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

We defined the Korean unique safety-critical software development methodology by modifying Dr. Harel`s statechart-based on formal methods in order to digitalized the reactor protection system. It is suggested software requirement specification guideline to specify design specification which is basis for requirement specification and automatic programming by the caused by shutdown parameter logic of the steam generator water level for Wolsung 2/3/4 unit SDS no.1 and simulated it by binding the Graphic User Interface (GUI). We generated the K and R C code automatically by utilizing the Statemate MAGNUM Sharpshooter/C code generator. Auto-generated K and R C code is machine independent code and has high productivity, quality and provability. The following are the summaries of major research and development. - Set up the Korean unique safety-critical software development methodology - Developed software ...

1998-06-01

338

Probabilistic power generation planning with environmental consideration for Lebanon  

International Nuclear Information System (INIS)

Full text.This paper describes a software tool for generation expansion planning based on dynamic programming, probabilistic production simulation, and environmental assessment. The aim is to determine the units needed to expand a given system in order to minimize either the cost or the environmental impact or some weighed function of the two. The problem of generation expansion planning is solved in stages using Tunnel Dynamic Programming (TDP) with Heuristic rules to limit the number of options analyzed. The production costing methodology is based on combining a probabilistic generation model known as the capacity outage table (COT) with the load duration curve (LDC) of the system to deduce a risk model from which the expected energy not supplied (EENS) is estimated. The generation model is built recursively using an efficient numerical convolution procedure and is combined at each step with the LDC ...

2000-11-23

339

Performance evaluation of a vortex generator heat transfer surface and comparison with different high performance surfaces  

International Nuclear Information System (INIS)

A comparative assessment of five different heat transfer configurations for operation in compact heat exchangers is presented. The configurations under consideration are four standaed heat exchanger surfaces - two plain fin, an offset strip and a louvered fin geometry - and one surface with so called vortex generators for heat transfer augmentation. In the case of the standard surfaces, the basic performance characteristics in the form of heat transfer and friction data versus the Reynolds number have been taken from published experimental results. In the case of the vortex generator surface, the performance characteristics have been derived from a numerical prediction of the flow and temperature field in a closely spaced parallel plate channel with vortex generators in the form of delta wings mounted on the channel walls. In comparison to the plain fin surfaces with a rectangular cross section, the vortex ...

1993-01-01

340

Numerical Simulation and Analyses of the Loss of Feedwater Transient at the Unit 4 of Kola NPP  

Science.gov (United States)

A three-dimensional numerical simulation of the loss-of-feed water transient at the horizontal steam generator of the Kola nuclear power plant is performed. Presented numerical results show transient change of integral steam generator parameters, such as steam generation rate, water mass inventory, outlet reactor coolant temperature, as well as detailed distribution of shell side thermal-hydraulic parameters: swell and collapsed levels, void fraction distributions, mass flux vectors, etc. Numerical results are compared with measurements at the Kola NPP. The agreement is satisfactory, while differences are close to or below the measurement uncertainties. Obtained numerical results are the first ones that give complete insight into the three-dimensional and transient horizontal steam generator thermal-hydraulics. Also, the presented results serve as benchmark tests for the assessment ...

2002-07-01

341

Evaluation of specific consumption from the use of chicken oil biodiesel in one cylinder generator set; Avaliacao do consumo especifico a partir da utilizacao de biodiesel de oleo de frango em um grupo-gerador monocilindrico  

Energy Technology Data Exchange (ETDEWEB)

Biodiesel can be produced from numerous materials, including by-products of animal chain. In this scenario, the chicken's oil, that is located and an environment not explored for biodiesel production, can be a good alternative in South and Southeast Brazilian Region, where they are slaughtered around 9.100.000 chickens per day. In order to determine the specific consumption from a generator set with single cylinder 6.6 kW of power and generation capacity of 5 kW, using chicken oil biodiesel (B-100), were performed the bench test using a auxiliary tank, precision scale and an energy analyzer. Were conducted four treatments (25%, 50%, 75% and 100% of generating capacity). The worst SC was the engine at 25% of generation capacity (1.5 kW) and better with 75% of maximum load (3.75 kW) with a mean of 479.34 g kWh{sup -1}. By Turkey's test ant 5% probability there was a ...

2010-07-01

342

Electrical wind generation, feasibility study and analysis in Lebanon  

International Nuclear Information System (INIS)

Full text.This paper is to investigate the potentials and possibilities of electrical generation via wind turbine. Special attention is directed to the interpretation of wind generation characteristics and parameters found in Lebanon and linking the electrical energy to the Lebanese slectric grid. Although much of the wind energy research is very well established and boomed globally (USA, Europe, India and China), in Lebanon is never used. At a time when climate scientists are increasingly concerned about carbon dioxide emissions from coal and diesel plants, and the nuclear industry is drying, the significance of a major new source os electricity is clear. there are many motives and feasibility criteria for qind power generation in Lebanon. They include the need for increasing the Lebanese electrical capacity, reducing air pollution, alternative energy sources and prices and availability of oil. The ...

1999-11-02

343

Ballard fuel cells and the changing energy landscape  

Energy Technology Data Exchange (ETDEWEB)

The numerous challenges facing the North American electric utility industry were discussed. In addition to competition, electric utilities are faced with low demand growth, public pressure to avoid adding transmission and distribution capacity, and strict environmental requirements. In view of these developments, large central generation additions that have been industry norm until recently, do not always make economic sense in the current environment. Instead, smaller, distributed additions to generating capacity is becoming the new norm. Small-scale on-site generating capacity has the added advantage of reducing the need for expensive high-voltage transmission lines. The Ballard generation system described here is a modular, efficient fuel cell-based solution to implementing distributed power concepts. The system is natural gas fueled, with low noise, vibration and emissions. ...

1997-02-01

344

CFD simulation of steam generator tube rupture thermal-hydraulics  

Energy Technology Data Exchange (ETDEWEB)

Several steam generator tube rupture accidents have occurred at plants in the past. In this paper the Computational Multi-Fluid Dynamics (CMFD) investigation of the horizontal steam generator thermal-hydraulics during the tube rupture accident is performed. A guillotine of a steam generator U-tube is assumed with choked flow from the primary to the secondary side of the steam generator. We have computed water and steam velocity fields, steam volume fraction distribution on the steam generator secondary (shell) side, as well as the swell level increase. The simulation results are a support to the safety analyses of the steam generator tube rupture accident. Numerical simulation is performed with the multidimensional multi-fluid modelling approach. The two-phase flow around steam generator tubes in the bundle is modelled by the porous media ...

2004-07-01

345

Guide to Combined Heat and Power Systems for Boiler Owners and Operators  

Energy Technology Data Exchange (ETDEWEB)

Combined heat and power (CHP) or cogeneration is the sequential production of two forms of useful energy from a single fuel source. In most CHP applications, chemical energy in fuel is converted to both mechanical and thermal energy. The mechanical energy is generally used to generate electricity, while the thermal energy or heat is used to produce steam, hot water, or hot air. Depending on the application, CHP is referred to by various names including Building Cooling, Heating, and Power (BCHP); Cooling, Heating, and Power for Buildings (CHPB); Combined Cooling, Heating, and Power (CCHP); Integrated Energy Systems (IES), or Distributed Energy Resources (DER). The principal technical advantage of a CHP system is its ability to extract more useful energy from fuel compared to traditional energy systems such as conventional power plants that only ...

2004-08-19

346

Simplified fusion power plant costing. A general prognosis and call for `new think`  

Energy Technology Data Exchange (ETDEWEB)

A top-level costing model is developed and used to project the cost of electricity (COE) (in mills per kilo watt-hour) expected from conceptual fusion power plants. Application is restricted to magnetic fusion energy (MFE) concepts. These costs are estimated parametrically in terms of the mass of the fusion-power-core (FPC) heater, the power required to sustain a reacting deuterium-tritium plasma, the heat transport/transfer system that delivers the fusion power to the balance of plant (BOP), and the BOP needed to convert the fusion heat to electrical power. Although the highly integrated (simplified) cost-estimating relationships (CERs) used to express COE in terms of FPC mass power density (MPD) [in kilowatt(electric) per tonne] and the engineering gain Q{sub E} (inverse of fraction of gross electric power recirculated to the fusion ...

1995-03-01

347

The first 750 MW block of the South Humber Bank gas-fired combined cycle power plant is commissioned; Humberin 750 MW ykkoesblokki vihitty kaeyttoeoen  

Energy Technology Data Exchange (ETDEWEB)

The first 750 MW block of the new South Humber Bank gas-fired combined cycle power plant, sited about 300 km north from London, was officially commissioned in September 12th 1997. The project has been a major success story for Imatran Voima Oy (IVO), which developed the concept and managed the project and owns 22.5 % of the plant; and ABB Power Plants Limited, responsible for the turnkey delivery. IVO Generation Services (UK) is responsible for the running and maintenance of the facility. IVO also manages two other existing plants in Britain, at Brigg (240 MW) and Peterborough (360 MW)

1997-12-31

348

The first 750 MW block of the South Humber Bank gas-fired combined cycle power plant is commissioned  

International Nuclear Information System (INIS)

The first 750 MW block of the new South Humber Bank gas-fired combined cycle power plant, sited about 300 km north from London, was officially commissioned in September 12th 1997. The project has been a major success story for Imatran Voima Oy (IVO), which developed the concept and managed the project and owns 22.5 % of the plant; and ABB Power Plants Limited, responsible for the turnkey delivery. IVO Generation Services (UK) is responsible for the running and maintenance of the facility. IVO also manages two other existing plants in Britain, at Brigg (240 MW) and Peterborough (360 MW).

349

Some sensitivities during a LWR severe core-damage sequence  

International Nuclear Information System (INIS)

Stable boiloff of core water during a severe LWR accident, that is, boiloff driven only by the decay power generated below the water level, is tractable analytically and is relatively insensitive to axial power distribution. As might be expected, calculated accident event times are sensitive to the fidelity of the decay power model. During later stages of boiloff, heat transfer or transport of energy from above the water level to the residual water can result in an unstable condition during which the boiloff rate increases greatly. The unstable boiloff phenomenon illustrates the highly nonlinear influence of core heat transfer during meltdown and emphasizes the great accuracy requirements which attend the modeling of the accident during periods of enhanced heat transfer when significant zirconium oxidation is possible.

1981-12-04

350

Negative-ion based NBI system for JT-60U  

Energy Technology Data Exchange (ETDEWEB)

A 500 keV negative-ion based NBI system is under construction for NB current drive and plasma core heating in high density plasma in JT-60U. Part of the beamline and the high voltage power supply required for a verification test of an ion source was completed in March 1995. After having done a high potential test of the power supply, the negative-ion generation and acceleration tests started in June 1995 aiming at deuterium beams of 500 keV, 22A. In initial experiment, deuterium negative-ion beams of 410 keV, 6.1A (2.5 MW) for 0.2 sec, so far, have been achieved. This is the world highest D{sup {minus}} current and negative ion beam power. The construction of the total system will be completed by the beginning of 1996, and the beam injection will start in March 1996.

1995-12-31

351

Identification of model parameters of excitation system and power system stabilizer of Mingtan{number_sign}6 via finalization field tests  

Energy Technology Data Exchange (ETDEWEB)

Experiences with the model parameter identification of the excitation system (EXS) and the power system stabilizer (PSS) for Mingtan{number_sign}6 pumped storage generation unit of Taiwan Power System are presented in this paper. The input-output data corresponding to each block of the EXS and PSS were obtained when the finalization tests of this unit were performed. The generalized least squares (GLS) approach is introduced and employed to identify the desired parameters of the noisy excitation system and PSS models. In this method, the reduction technique of biased estimates due to the non-white (correlated) identification residual is also applied to improve the accuracy of identification. The results of the parameter estimation are satisfactory. The GLS parameter identification method using the measured data at finalization tests is then suggested from the viewpoint of economy and engineering.

1995-05-01

352

Estimation of nonfuel operation and maintenance costs for advanced circulating fluidized-bed and advanced natural gas-fired combined cycle power plants  

Energy Technology Data Exchange (ETDEWEB)

Operation and maintenance cost estimating methodologies for advanced coal-fired atmospheric circulating fluidized-bed and advanced natural gas-fired combined cycle electric power plants are presented. The purpose of these cost estimating relationships is for use in long range planning and evaluation of the economics of use of these technologies for electric power generation. Projected annual costs of reference plants at ten different sites in the United States, one in each of the ten DOE regions, are given as of 1989, and comparisons are made with existing technologies. A listing of a computer program implementing the methodologies is included. 14 refs., 4 figs., 13 tabs.

1989-12-01

353

Draft Regulatory Rule-making for On-line Maintenance of Nuclear Power Plants  

International Nuclear Information System (INIS)

Internationally, on-line maintenance (OLM) of nuclear power plants under the operation is prevailed to enhance nuclear safety and economics. In recent years, Korea Hydro and Nuclear Power Co. Ltd. (KHNP) is eager to apply OLM. Ministry of Education, Science and Technology (MEST) has established the related technology development program as an item of 'Overall Planning on Nuclear Safety(2010-2014)' through acceptance to the request of KHNP in 2009. OLM is defined as maintenance that is performed with the main generator connected to the grid. In other words, it means a preventive maintenance to be implemented during the allowable outage time (AOT) with ignoring inoperability of safety-related equipment listed in the technical specifications. The Korea Institute of Nuclear Safety (KINS) is developing the assessment technology of safety concerns for OLM under the auspices of MEST. Draft regulatory rule-making for OLM is devised ...

2010-10-01

354

Behaviour of steam turbine power control of large power plant units in case of network short-circuits  

International Nuclear Information System (INIS)

In order to investigate the behaviour of the turbine control system during strong pendulum motions, an analysis is carried out using a digital computer program by which the reactor, the turbine, the generator and, in a simplified way, the network can be simulated to the necessary degree. Plotter pictures can show the main physical quantities. In all cases, the turbine control system should be able to distinguish between strong pendulum amplitude with acceleration of the rotational angles and sudden release criteria. This demand can be satisfied by a simple adjustment in the Kraftwerk Union turbine control system. Only a few seconds after shut-off of a severe network failure, the turbines are back to their rated power, thus contributing to reliability of supply in this critical network situation. (orig.).

1978-11-24

355

Application of nuclear energy for power generation at TAPS 3 and 4  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station, Unit 3 and 4 is located on the West Coast of the Arabian Sea near the existing Tarapur Atomic Power Station Unit 1 and 2. The nearest railway station is Boisar at a distance of 12 km from the site, which is on the main Western Railway Mumbai-Delhi route. The site is well connected by road and is about 30 Km from Mumbai-Ahmedabad National Highway-NH-8. The paper describes the land acquisition and rehabilitisation of the affected families, importance of project in the western grid, how it works, working principles of PHWR, principle of operation, major components/equipment, important systems, safety features, and waste management

2010-10-01

356

Advanced resin cleaning system  

International Nuclear Information System (INIS)

Novel and unprecedented ion exchange resin cleaning system, for use in BWR plants and featuring a vibration separator and basic design factors of Radiological Solutions, Inc., had been delivered to Tokai No. 2 Power Station, Japan Atomic Power Company, in October 2005. This compactly-designed system effectively separates crud and resin fines from ion exchange resins, with no clogging of separation screens. It generates minimized waste liquid and has a specially designed over-pack cleaning tank. The system has been in operation for about 2 years and half now and favorable operational data, such as crud and sulfate concentration decrease in feed water and reactor water respectively, and evaluation results have been reported from Japan Atomic Power Company and so on. (author)

2008-07-01

357

A study of solar-powered, high-altitude unmanned aerial vehicles  

British Library Electronic Table of Contents (United Kingdom)

Purpose ? Aims to present a methodology for analysing a solar-electric, high-altitude, long-endurance, unmanned aircraft. Design/methodology/approach ? The study focuses on the aerodynamics, flight performance and power requirements of a heavier-than-air, solar-electric, HALE UAV. The methodology is founded on using an analytical approach to determine the power required to undertake various flight manoeuvres. An analytical approach is also undertaken in determining the intensity of the solar radiation available to the aircraft. Finally to demonstrate the methodology, a HALE concept was generated and evaluated. Findings ? When using estimates of current solar-electric propulsion and energy conversion efficiencies, the HALE concept was only able to sustain year round, level flight up to lati...

2006-01-01

358

A new fuzzy decision-making procedure applied to emergency electric power distribution scheduling  

Energy Technology Data Exchange (ETDEWEB)

In this paper a new fuzzy decision-making procedure is developed. Two levels of weightings, called upper and lower weights, are proposed to calculate the fuzzy weightings of different criteria. The preference table is introduced to calculate the upper and lower weights. Also a new method is developed to determine the expected preference values of different alternatives. These values are used for generating the priority list of alternatives. The procedure is applied for providing an emergency electric power distribution, scheduling time table. The IEEE 14-bus standard system and a 14-bus system with four power plants are considered as case studies. Using fuzzy decision-making procedure, the regions with more priorities are more connected to the distribution net, while the maximum consumption criterion is also reasonably respected. (author)

2000-12-01

359

A high sensitivity two-color interferometer for pulsed power plasmas  

International Nuclear Information System (INIS)

A high sensitivity, high bandwidth, two-color interferometer (1064 and 532 nm) has been tested on the Hawk pulsed power generator at the Naval Research Laboratory. The phase resolution is 10"-"5 waves with a rise time of 3 ns, a new capability for diagnosing plasmas, and neutrals in pulsed power experiments. The two-color feature is used to distinguish phase shifts from free (plasma) electrons and bound (neutral and ion) electrons. Simultaneous electron and neutral density measurements were demonstrated in a plasma opening switch (POS) experiment. The ability to measure small phase shifts with fast rise time were demonstrated in a plasma filled diode experiment. The high sensitivity and vibration isolation enable neutral gas distribution measurements from supersonic nozzles used in plasma radiation source experiments. Examples of these measurements and future applications are described. copyright 1997 American Institute of ...

360

Power plants 2009. Lectures  

Energy Technology Data Exchange (ETDEWEB)

Within the Annual Conference 2009 of the VGB PowerTech e.V. (Essen, Federal Republic of Germany) from 23rd to 25th May, 2009, in Lyon (France) the following lectures were held: (1) Electricity demand, consequences of the financial and economic crisis - Current overview 2020 for the EU-27 (Hans ten Berge); (2) Status and perspectives of the electricity generation mix in France (Bernard Dupraz); (3) European electricity grid - status and perspective (Dominique Maillard); (4) Technologies and acceptance in the European energy market (Gordon MacKerran); (5) EPR construction in Finland, China, France, (Claude Jaouen); (6) EPR Flamanville 3: A project on the path towards nuclear revival (Jacques Alary); (7) Worldwide nuclear Revival and acceptance (Luc Geraets); (8) An overview on the status of final disposal of radioactive wastes worldwide (Piet Zuidema); (9) Who needs pumped storage plants? PSP are partner to grid stability and renewable energies ...

2009-07-01

361

Power plants 2009. Lectures  

International Nuclear Information System (INIS)

Within the Annual Conference 2009 of the VGB PowerTech e.V. (Essen, Federal Republic of Germany) from 23rd to 25th May, 2009, in Lyon (France) the following lectures were held: (1) Electricity demand, consequences of the financial and economic crisis - Current overview 2020 for the EU-27 (Hans ten Berge); (2) Status and perspectives of the electricity generation mix in France (Bernard Dupraz); (3) European electricity grid - status and perspective (Dominique Maillard); (4) Technologies and acceptance in the European energy market (Gordon MacKerran); (5) EPR construction in Finland, China, France, (Claude Jaouen); (6) EPR Flamanville 3: A project on the path towards nuclear revival (Jacques Alary); (7) Worldwide nuclear Revival and acceptance (Luc Geraets); (8) An overview on the status of final disposal of radioactive wastes worldwide (Piet Zuidema); (9) Who needs pumped storage plants? PSP are partner to grid stability and renewable energies ...

2009-09-23

362

The THz Radiation from Undulator  

Science.gov (United States)

The experimental device for generation of undulator radiation in terahertz wavelength region by use of undulator with ferromagnets is created. The device is based on a beam of a microtron with the energy 7.5 MeV. The radiation wavelength is 200 mu. Registered spontaneous radiation has a power 10{sup -6} W at a current of a beam 2 mA in a pulse. With the optical resonator, in a mode, the amplification of 6% is received, that in sometimes is more than the expected value. This effect is explained as a result of partial coherence of radiation.

2010-02-03

363

Test and simulation of dynamic phase compensation from Mita-Teknik A/S  

Energy Technology Data Exchange (ETDEWEB)

This report describes the test of a dynamic phase compensation unit for a wind turbine with directly connected induction generators. The compensation unit is based on thyristor switched capacitors, where conventional wind turbine compensations use mechanical contactors to switch the capacitors. The influence on power quality analysed, and influence on component lifetime is discussed. Besides, simulation models in Matlab/Simulink are presented, including a flicker meter model. (au)

2004-03-01

364

Study on the evaluation of vibration effect and the development of vibration reduction method for Wolsung unit 1 main steam piping.  

Science.gov (United States)

The main steam piping of nuclear power plant which runs between steam generator and high pressure turbine has been experienced to have a severe effect on the safe operation of the plant due to the vibration induced by the steam flowing inside the piping. ...

1996-01-01

365

Steam turbine operation and damages after long term use; Dampfturbinenbetrieb und Schaeden nach langer Einsatzzeit  

Energy Technology Data Exchange (ETDEWEB)

Allianz Global Corporate and Specialty AG, the industrial insurance carriers of Allianz Group and AZT Risk and Technology GmbH, have a lot of experience and a comprehensive database about damage of industrial steam turbines and large-scale power generation turbosets. Sound maintenance concepts are the main loss prevention measure, which will be presented and discussed in detail. Some modifications and additions to existing maintenance concepts are also provided.

2008-07-01

366

Solar cells  

Energy Technology Data Exchange (ETDEWEB)

The article is the second part of a review dealing with latest developments in the area of solar cell technologies and application. Physical principles, design and efficiency as well as advantages and disadvantages of GaAs- and CdS-solar cells are described. Power generation solar cell systems with voltage converters, combined solar cell/solar collector systems and thermoelectric solar systems are presented in the second part of the article.

1983-04-01

367

Pumped storage plants  

Energy Technology Data Exchange (ETDEWEB)

Pumping is one of the means for storing vast quantities of energy. This article analyses its principles and ways of implementation with emphasis on its double aspect, e.g., on the one hand, off-peak power is transferred to the periods of heaviest load and is thus valorized, even when taking into account losses due to poor efficiency of operations in the pumping and turbine modes, and on the other hand, plants have great flexibility in operation, faciliting the permanent fitting of generation to demand.

1982-09-01

368

Proceedings of the meeting on the technical study at KEK  

International Nuclear Information System (INIS)

Technical studies on constructing the J-PARC (Japan Proton Accelerator Research Complex) are presented by five authors: (1) on the wiring for electromagnets of the 50 GeV synchrotron, (2) on the fast beam-extraction from the 50 GeV synchrotron into two opposite directions, (3) on the target chamber system for the generation of muons, (4) on the design of large aperture electromagnets, and (5) on the maintenance and control of the electromagnet power supplies. (K.Y.)

2006-11-28

369

No 2965, No 254. Report on new energy technologies and carbon dioxide sequestration: scientifical and technical aspects; N. 2965, N. 254. Rapport sur les nouvelles technologies de l'energie et la sequestration du dioxyde de carbone: aspects scientifiques et techniques  

Energy Technology Data Exchange (ETDEWEB)

The abatement of CO{sub 2} emissions is a huge technical and economical challenge. Fossil fuels, which represent 88% of the world primary energy consumption, are the main source of the 25 billions of CO{sub 2} released each year in the atmosphere. The mastery of CO{sub 2} emissions cannot come from a single technology but must result from the simultaneous implementation of several means, like the development of carbon-free energies and the mastery of fossil fuel emissions. The opportunities of progress are numerous and compatible with the economic development. This document presents, first, the different greenhouse gases, the CO{sub 2} emissions per country and the main sources of CO{sub 2} emissions (power and heat generation, transports). Then it presents different ways of abatement of CO{sub 2} emissions: clean coal technologies, gas combined cycles, CO{sub 2} sequestration, reduction of fuel consumption in transports, development of ...

2006-03-15

370

New uses for coal  

Energy Technology Data Exchange (ETDEWEB)

As oil supplies diminish, Britain will have to rely more and more on coal as one of the energy alternatives. To burn coal cleanly and efficiently coal will have to be converted into gas and liquid fuels to replace natural gas and oil. The research and development programme of the National Coal Board is directed towards meeting these new challenges. This paper outlines some of the Coal Board's current projects in the fields of industrial combustion, power generation, domestic combustion, coal gasification and coal liquefaction. 10 figs.

1981-01-01

371

Method of controlling the coolant level in the cooling system of a nuclear power plant  

International Nuclear Information System (INIS)

Object: To prevent a sudden drop in the level of a coolant in a annular pipe encased within a downcomer pipe. Structure: The coolant levels in annular pipes encased within downcomer pipes are simultaneously measured by level gauges which generate signals representative of coolant levels. The signals are fed to a level control system which will actuate valves to regulate the cover gas pressure in order to average the level differences among the annular pipes in different downcomer pipes. (Kamimura, M.).

372

Layout 1 - NASA  

Science.gov (United States)

The solar array wings were deployed by swinging two half-blanket boxes open from a folded hinge launch position .... pure-water by-product of the shuttle's fuel cell power generators because ..... outgassing limits, flammability limits, ... Foale fills a water microbiology bag for in-flight analysis. ...

373

Government to buy low-cost energy from non-utility sources  

Energy Technology Data Exchange (ETDEWEB)

Power generated by manufacturers and third-party suppliers in venture capital projects is available to military and other government users at a cost 10 to 20% lower. Tax benefits and other financial incentives keep suppliers' costs low. Users are required to contract for a minimum amount of energy over a 20- to 30-year period. Military use of these energy projects includes sources based on solar energy, cogeneration, geothermal heat, and refuse-derived fuel. (DCK)

1983-04-04

374

Flexible DER Utility Interface System: Final Report, September 2004--May 2006  

Energy Technology Data Exchange (ETDEWEB)

In an effort to accelerate deployment of Distributed Energy Resources (DER) such as wind, solar, and conventional backup generators to our nation's electrical grid, Northern Power Systems (NPS), the California Energy Commission (CEC), and the National Renewable Energy Laboratory (NREL) collaborated to create a prototype universal interconnect device called the DER Switch.

2006-08-01

375

Externally fired combined cycle for electric power generation from coal  

Energy Technology Data Exchange (ETDEWEB)

The externally fired combined cycle is emerging as an economically viable repowering options for old non-competitive coal fired steam plants. This paper describes the initial operation of a pilot plant located at Kennebunk, Maine and the initial work on the repowering of a 48MW coal fired steam plant located in Warren, PA.

1994-12-31

376

ENERGY EFFICIENCY AND ENVIRONMENTALLY FRIENDLY DISTRIBUTED ENERGY STORAGE BATTERY  

Energy Technology Data Exchange (ETDEWEB)

Electro Energy, Inc. conducted a research project to develop an energy efficient and environmentally friendly bipolar Ni-MH battery for distributed energy storage applications. Rechargeable batteries with long life and low cost potentially play a significant role by reducing electricity cost and pollution. A rechargeable battery functions as a reservoir for storage for electrical energy, carries energy for portable applications, or can provide peaking energy when a demand for electrical power exceeds primary generating capabilities.

2006-04-30

377

Dual fuel engine solves the solvent problem  

Energy Technology Data Exchange (ETDEWEB)

Some 200 visitors attended the official opening of a new diesel engine driven cogeneration plant in the city of Hamburg at the end of March. The dual fuel engine built by Blohm+Voss will supply 7.7 MW of electricity to the grid and 8.26 MW of thermal power to generate steam and hot water. (author)

1993-05-01

378

DOE supports market-based pricing in case before FERC  

Energy Technology Data Exchange (ETDEWEB)

The Department of Energy has used its seldom-used statutory authority and filed comments with the Federal Energy Regulatory Commission urging support for Public Service Company of Indiana's request that the FERC allow it to sell up to 450 megawatts of firm power to eligible wholesale purchasers at negotiated or market-based rates in exchange for open transmission access for other generators.

1990-04-12

379

Control device for condensate cleanup system  

International Nuclear Information System (INIS)

Purpose: To ensure continuous operation for condensate desalters with the control device for desalter group in a nuclear power plant by automatically averaging the operation interval between each of the desalters. Constitution: Electroconduction meters are provided at the inlet and the outlet for each of the desalters. The conduction rates at the inlet and outlet are compared to determine the re-generation timing of the condensate desalter. Limiting set value for each of the equipments in the cleanup systems is changed by using a mathematical operation circuit to average the operation interval between each of the desalters. (Ikeda, J.).

380

Continuous emission monitoring -- Data acquisition and handling system for management  

Energy Technology Data Exchange (ETDEWEB)

This paper describes New York State Electric and Gas Corporation`s concept for a comprehensive, centrally located data system for management of their continuous emission monitoring systems (CEMS) data. The topics of the paper include the power system`s mix of generating units; data reporting requirements; data base management; nitrogen oxides compliance tracking; sulfur dioxide, nitrogen oxides, carbon dioxide and flow monitoring; and allowance tracking.

1995-09-01

381

Coal uses and upgrading processes  

Energy Technology Data Exchange (ETDEWEB)

The paper discusses the status of coal as a raw material and energy source. After referring to coal preparation and the costs it involves the author deals with coal/liquid suspensions and their fueling uses. Access is given to different aspects concerning the use of coal for electric power and heat generation. They include pollution abatement measures, economic analyses and fuel engineering in the case of coal. Further sections are dedicated to upgrading procedures such as the gasification, liquefaction and coking of coal. A bibliography informs the reader about further publications available on the subject. (HAG).

1986-04-01

382

Chalk Point Cooling Tower Project. Volume 2. Cooling Tower Drift Dye Tracer Experiment, June 16 and 17, 1977.  

Science.gov (United States)

A drift dye tracer experiment, using Rhodamine (WT) dye, was conducted on airborne drift from a natural draft cooling tower at PEPCO's Chalk Point, Maryland Power Generating Station. This experiment was designed to separate and identify cooling tower aero...

1977-01-01

383

Basic study of solid oxide fuel cells. Part 5: investigation of fuel cell materials  

Energy Technology Data Exchange (ETDEWEB)

Solid Oxide Fuel Cell (SOFC) is expected as a new power generation source. The development of SOFC is being conducted by CRIEPI, and so far several reports of the reults were presented. This report examines materials of SOFC. For the purpose, cells were made using some of typical materials and manufacturing processes, and cell performance tests were carried out.

1991-01-01

384

BP Industrial Synergies Opportunities Investigation (3B6)  

Wastenet

... However, Hydrogen Energy is working towards establishing hydrogen-fired power generation facilities in other parts of the world (e.g. California, Abu Dhabi and elsewhere) and the synergies work carried out for the Kwinana proposal would provide a good starting basis for other proposals. ...

385

Analysis of the economic potential of the landfill in the municipality of Chapeco - SC, Brazil; Analise do potencial economico do aterro sanitario do municipio de Chapeco - SC  

Energy Technology Data Exchange (ETDEWEB)

This study aims to evaluate the economic and environmental viability of the exploitation of methane gas (CH4) - biogas - concentrated at the bottom of the mountains of waste from landfill Chapeco for power generation. The landfill receives approximately of 80 tons / day, the vast majority of domestic origin.

2006-07-01

386

Acceptance test guideline for steam turbine control systems. Anahmerichtlinie fuer Regel- und Steuereinrichtungen von Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

The acceptances to be obtained during the first operational run, refer to measures proving the functional integrity of the turbine control system and assuring the compliance with the maximum allowable overspeed in case of lead changes or perturbations. The Guideline concerns essentially speed, power, and pressure controllers coupled to generators. It may be appropriately extended to steam turbines serving other purposes.

1983-01-01

387

Horizontal Steam Generator Thermal-Hydraulics at Various Steady-State Power Levels  

Science.gov (United States)

Three-dimensional computer simulation and analyses of the horizontal steam generator thermal-hydraulics of the WWER 1000 nuclear power plant have been performed for 50% and 75% partial loads, 100% nominal load and 110% over-load. Presented results show water and steam mass flow rate vectors, steam void fraction spatial distribution, recirculation zones, swell level position, water mass inventory on the shell side, and other important thermal-hydraulic parameters. The simulations have been performed with the computer code 3D ANA, based on the 'two-fluid' model approach. Steam-water interface transport processes, as well as tube bundle flow resistance, energy transfer, and steam generation within tube bundles are modelled with {sup c}losure laws{sup .} Applied approach implies non-equilibrium thermal and flow conditions. The model is solved by the control volume procedure, which has been extended in order to ...

2002-07-01

388

Horizontal Steam Generator Thermal-Hydraulics at Various Steady-State Power Levels  

International Nuclear Information System (INIS)

Three-dimensional computer simulation and analyses of the horizontal steam generator thermal-hydraulics of the WWER 1000 nuclear power plant have been performed for 50% and 75% partial loads, 100% nominal load and 110% over-load. Presented results show water and steam mass flow rate vectors, steam void fraction spatial distribution, recirculation zones, swell level position, water mass inventory on the shell side, and other important thermal-hydraulic parameters. The simulations have been performed with the computer code 3D ANA, based on the 'two-fluid' model approach. Steam-water interface transport processes, as well as tube bundle flow resistance, energy transfer, and steam generation within tube bundles are modelled with "closure laws". Applied approach implies non-equilibrium thermal and flow conditions. The model is solved by the control volume procedure, which has been extended in order to take into account the 3D ...

2002-04-14

389

Energy analysis of a solar pre-water heating system; Analise energetica de um sistema de pre-aquecimento solar de agua  

Energy Technology Data Exchange (ETDEWEB)

Several technological alternatives have been studied taking into consideration that one of the biggest problems of the electric power companies is to provide electric power during the peak consumption periods, which largest contribution to the increase of the demand comes from the residential sector, especially by the use of electric showers. One of the most promising alternatives is the pre-water heating system for reduced power showers, developed by Universidade de Campinas and Companhia Paulista de Forca e Luz. The goal of this system is basically to reduce demand during the peak periods, in order to avoid heavy investments by the electric power companies in generation, transmission and distribution of electric power directed to low acquisitive power customers, a sector in which the electric power price is not enough ...

1996-12-31

390

UMCP-BG and E collaboration in nuclear power engineering in the framework of DOE-Utility Nuclear Power Engineering Education Matching Grant Program  

Energy Technology Data Exchange (ETDEWEB)

The DOE-Utility Nuclear Power Engineering Education Matching Grant Program has been established to support the education of students in Nuclear Engineering Programs to maintain a knowledgeable workforce in the United States in order to keep nuclear power as a viable component in a mix of energy sources for the country. The involvement of the utility industry ensures that this grant program satisfies the needs and requirements of local nuclear energy producers and at the same time establishes a strong linkage between education and day-to-day nuclear power generation. As of 1997, seventeen pairs of university-utility partners existed. UMCP was never a member of that group of universities, but applied for the first time with a proposal to Baltimore Gas and Electric Company in January 1999 [1]. This proposal was generously granted by BG&E [2,3] in the form of a gift in the amount of $25,000 from ...

2000-03-01

391

Online monitoring of power transformers - a new low-cost system for small and medium power transformers; Monitoring von Leistungstransformatoren - Jetzt auch fuer kleine und mittlere Baugroessen  

Energy Technology Data Exchange (ETDEWEB)

Until now, monitoring of power transformers focussed mainly large generator and network transformers. Siemens goes a step ahead and provides a system especially developed and designed for small and medium power transformers, e.g. for the 100 kV level. This low cost version could be achieved by restriction to really necessary measuring quantities. This allows to realize also for small and medium power transformers an online monitoring including an estimation of aging and as an option an early warning to avoid unexpected failures. (orig.) [German] Die Ueberwachung (Monitoring) von Leistungstransformatoren war bisher vor allem fuer Maschinentransformatoren und grosse Netzkuppeltransformatoren in der Diskussion. Siemens geht einen Schritt weiter und stellt nun auch ein System bereit, das speziell fuer kleine und mittlere Leistungstransformatoren, z.B. der 110-kV-Spannungsebene, konzipiert ist. Diese ...

1999-09-20

392

On appraising alternative power plant investment proposals. Pt. 1: The economic model  

Energy Technology Data Exchange (ETDEWEB)

Combined energy plants operating on the Brayton-Rankine cycle have gained wide acceptance as the most efficient energy conversion system. The technology is well proven and numerous research activities are underway to develop it further past its present plateau of performance. In developed and emerging economies alike, the current situation in the global economic market has caused the liberalisation of the energy industry in some countries, and in others it is causing a rethink of economic and energy policies. A result is that electric utility companies that have enjoyed a monopoly in power generation and distribution are seeing this privilege being eroded. This is opening up opportunities for independent power production and, consequently, for gas/steam turbine plants because of the technical merits of the technology and its ability to fill the vacuum being created in the energy industry. An economic model has been ...

2000-12-01

393

Nuclear power and sustainable development  

International Nuclear Information System (INIS)

In Romania, the nuclear power is an element of sustainable development, being competitive, efficient and viable in the market economy. Fuel supply is ensured as nuclear fuel is manufactured in the country out of local uranium resources available in Romania. As for the environmental protection, it is known that, unlike the thermal power plants, the nuclear power plants do not release sulfur and nitrogen oxides, carbon dioxide and do not generate slag and ashes. The operation of nuclear power units does not release pollutants and, accordingly, these stations can contribute to the limitation and the abatement of environmental pollution. After seven years of Cernavoda NPP Unit 1 operation, a facility for storing low and medium level nuclear fuel wastes was built at the plant site as well as an intermediate dry storage for spent nuclear fuel whose first modules were commissioned in July ...

2003-07-01

394

Electricity generation: options for reduction in carbon emissions  

Energy Technology Data Exchange (ETDEWEB)

Historically, the bulk production of electricity has been achieved by burning fossil fuels, with unavoidable gaseous emissions, including large quantities of carbon dioxide: an average-sized modern coal-burning power station is responsible for more than 10 Mt of CO{sub 2} each year. This paper details typical emissions from present-day power stations and discusses the options for their reduction. Acknowledging that the cuts achieved in the past decade in the UK CO{sub 2} emissions have been achieved largely by fuel switching, the remaining possibilities offered by this method are discussed. Switching to less-polluting fossil fuels will achieve some measure of reduction, but the basic problem of CO{sub 2} emissions continues. Of the alternatives to fossil fuels, only nuclear power represents a zero-carbon large-scale energy source. Unfortunately, public concerns over safety and radioactive waste have still to be assuaged. ...

2002-07-01

395

Daya Bay Nuclear Power Station five-year business plan and operating results  

International Nuclear Information System (INIS)

Guangdong Nuclear Power Joint Venture Company, Ltd. first 5-Year Business Plan (hereinafter referred to as 5-Year Business Plan) serves as guidance of both the operations and management of the company. Continuous performance improvement of the nuclear power station has been achieved through the fulfillment of goals and improvement plan defined by the 5-Year Business Plan, and through standard and systematic management. Daya Bay Nuclear Power Station (GNPS) has made great contributions to sustainable economic developments of both Guangdong and Hong Kong since its commercial operation in 1994. As of the end of 1999, the cumulative off-take electricity generated by GNPS had reached 69.9 billion kWh. Of the WANO indicators universally applied by nuclear power industry throughout the world, 6 indicators of Daya Bay performance entered the world top quartile while 9 the medium level

2000-12-05

396

Air breakdown induced by a high-power short-pulse microwave  

Energy Technology Data Exchange (ETDEWEB)

At Himeji Institute of Technology, the high power microwaves with the peak power of 20 MW, frequency of 12 GHz and pulse duration of 14 ns have been produced with a virtual cathode oscillator (vircator). These high power microwaves offer new applications in various fields. One problem in laser-triggered lightning experiment is the strong attenuation of laser energy by rain, cloud and laser-produced plasma. Microwaves propagate in thundercloud with small loss, and also are able to irradiate much extensive region of targets. In this paper, the fundamental experiment on the air breakdown induced by high power, short pulse microwaves is reported. The experimental setup of the vircator diode for microwave generation is shown. The typical evolution of diode voltage, electron beam current and microwave emission from the top in the course of time is shown. The experimental setup for ...

1996-05-01

397

Research on ceramic gas turbine/electric hybrid system for city bus; Toshi bus yo gas turbine/denki hybrid system no saitekika ni kansuru kenkyu  

Energy Technology Data Exchange (ETDEWEB)

Study was made on the city bus driven by the series hybrid system composed of a small ceramic gas turbine (100kW), generator and lead storage battery. Two driving modes were adopted, 10-driving mode and real driving mode assuming a certain bus route in Tokyo. The motor is driven mainly by generated power and additionally by battery power, however, the engine/generator system is controlled at an optimum operation point (driving mode and regenerating mode) with a maximum thermal efficiency considering depth of discharge. Design voltage of the battery had nearly no effect on fuel consumption, while its capacity as large as possible was desirable unless its weight has an adverse effect on the system. The real driving mode was lower in fuel consumption by 39% than the 10-driving mode. Since real fuel consumption is largely affected by recovery rate of regenerable energy, the operation ...

1998-10-15

398

News from the world; Echos du monde  

Energy Technology Data Exchange (ETDEWEB)

This document gathers a series of very short articles concerning nuclear industry around the world. Areva company is investing 30 million euros in its Chalon-Saint-Marcel plant, it is the consequence of the extension of service life of nuclear power plants in the Usa. Areva holds 40% of the American market concerning the replacement of steam generators and 50% of that concerning the replacement of closure heads. The Obrigheim nuclear power plant was definitely closed down on may 2004, this decommissioning is a step forward in the German policy of progressively stepping out of nuclear energy. Chinese authorities are willing to construct 40 nuclear reactors in 15 years, despite that, the contribution of nuclear energy to the generation of electricity will reach only 4% in 2020. In 2007 Cea will begin the construction works of a new research reactor (Jules Horowitz reactor) in the Cadarache site. Prices of ...

2005-04-01

399

High-efficiency Hybrid Solar Cells for Micro-generation  

Environmental Research Database

Objectives1. To develop new photoactive materials and fabricate demonstration QD (quantum dot) solar cells. This will be achieved by:~%~1.1. Materials preparation and characterisation of QD/polymer systems~%~1.2. Optimising structures of QDs, nanorods and polymer for quantum yield and charge transfer~%~1.3 Fabricating demonstration QD/polymer solar cells and measuring power conversion efficiencies~%~2. To demonstrate multiexciton generation (MEG) and harvesting within nanostructured QDs. This will involv [continued...]DescriptionWidespread implementation of photovoltaic electricity to meet changing energy demands requires a step-change in the cost of photovoltaic power. This proposal assembles a consortium of chemists, physicists, materials scientists and electrical engineers from The University of Manchester and Imperial College London to address this need through the development of new low-cost, high-efficiency, ...

2010-01-30

400

Gas fired combined cycle plant in Singapore: energy use, GWP and cost-a life cycle approach  

Energy Technology Data Exchange (ETDEWEB)

A life cycle assessment was performed to quantify the non-renewable (fossil) energy use and global warming potential (GWP) in electricity generation from a typical gas fired combined cycle power plant in Singapore. The cost of electricity generation was estimated using a life cycle cost analysis (LCCA) tool. The life cycle assessment (LCA) of a 367.5 MW gas fired combined cycle power plant operating in Singapore revealed that hidden processes consume about 8% additional energy in addition to the fuel embedded energy, and the hidden GWP is about 18%. The natural gas consumed during the operational phase accounted for 82% of the life cycle cost of electricity generation. An empirical relation between plant efficiency and life cycle energy use and GWP in addition to a scenario for electricity cost with varying gas prices and plant efficiency have been established.

2005-08-15

401

Gas fired combined cycle plant in Singapore: energy use, GWP and cost-a life cycle approach  

International Nuclear Information System (INIS)

A life cycle assessment was performed to quantify the non-renewable (fossil) energy use and global warming potential (GWP) in electricity generation from a typical gas fired combined cycle power plant in Singapore. The cost of electricity generation was estimated using a life cycle cost analysis (LCCA) tool. The life cycle assessment (LCA) of a 367.5 MW gas fired combined cycle power plant operating in Singapore revealed that hidden processes consume about 8% additional energy in addition to the fuel embedded energy, and the hidden GWP is about 18%. The natural gas consumed during the operational phase accounted for 82% of the life cycle cost of electricity generation. An empirical relation between plant efficiency and life cycle energy use and GWP in addition to a scenario for electricity cost with varying gas prices and plant efficiency have been established.

2005-08-01

402

Economic and environmental advantages of natural gas-fueled combined-cycle electric power generation  

International Nuclear Information System (INIS)

The outlook for natural gas (from both supply and price perspectives) has improved dramatically since the late 1970s, and significant advances have been made in electrical generation technologies which use gas. For example, gas-fired combined-cycle turbine units have become even more efficient and reliable. These units can be installed quickly (12 to 24 months versus 8 to 15 years for coal and nuclear units), and they may be brought on-line in small incremental blocks. This modular construction feature offers greater flexibility to utility planners, and the relatively low capital cost of combined-cycle units reduces financial uncertainties. The purpose of this chapter is to compare two electric power generating options, a new coal-fired powerplant and a new natural gas fired combined-cycle unit, from both economic and environmental perspectives. The comparison is based on a 240 megawatt baseload system.

403

Cheng cycle cogeneration system; Cheng cycle system cogeneration setsubi  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the Cheng cycle system featured by variable heating/generation ratio for effective operation of cogeneration systems (CGS). In this system, a superheater and reheating burner are added to an exhaust heat recovery (EHR) boiler for conventional gas turbine CGSs, while additional injection steam piping is attached to a gas turbine. Steam is injected through manifolds mounted on the periphery of a combustion chamber, and hot gas mixture of steam and air in a combustion chamber is expanded in a turbine and converted to motive power. This technology thus can improve efficiency and output power, and can operate variably CGSs corresponding to heating and generation demands. This technology has been promoted by introducing the technology of middle class Cheng cycle CGS with 4MW class gas turbine from IPT Co., U.S.A. The first system of 6400 kW is now under production for start of operation in ...

1996-03-29

404

Nuclear new-build - Status and Outlook from a German utility perspective  

International Nuclear Information System (INIS)

Full text: As one of the Top 5 utilities in Europe, Rheinisch-Westfaelisches Elektrizitaetswerk AG, FWB: RW, RWE, operates a diversified generating capacity of about 45 GW; RWE Power alone generates over 30 GW. Besides a share of approximately 20% nuclear power, a large proportion of the generating base is in lignite and hard coal. RWE has an ambitious, Euro10 bn newbuild program of about 10 GW modern fossil fired plants and further expansion plans across Europe. By 2012, RWE intends to invest between Euro 15 and 20 bn outside Germany.The European Union has a challenging policy to increase the share of renewables, improve energy efficiency, and reduce greenhouse gases by 2020. At the same time, ageing power plants need to be replaced. This requires an enormous investment program across Europe. Nuclear power therefore, as a proven technology ...

2009-10-12

405

Solar thermal electricity in 1998: An IEA/SolarPACES summary of status and future prospects  

Energy Technology Data Exchange (ETDEWEB)

Research and development activities sponsored by countries within the International Energy Agency`s solar thermal working group. SolarPACES, have helped reduce the cost of solar thermal systems to one-fifth that of the early pilot plants. Continued technological improvements are currently being proven in next-generation demonstration plants. These advances, along with cost reductions made possible by scale-up to larger production and construction of a succession of power plants, have made solar thermal systems the lowest-cost solar energy in the world and promise cost-competitiveness with fossil-fuel plants in the future. Solar thermal technologies are appropriate for a wide range of applications, including dispatchable central-station power plants where they can meet peak-load to near-base-load needs of a utility, and distributed, modular power plants for both remote and grid-connected applications. In ...

1998-07-01

406

Review of Central Research Institute of Electric Power Industry. Coal utilization technology harmonious with the environment. Kankyou ni yasashii sekitann riyo gijyutu. Kankyo ni yasashii sekitan riyo gijutsu  

Energy Technology Data Exchange (ETDEWEB)

Studies are made on coal in terms of its effective utilization, coal cleaning, fluidization and production of new fuel, and issues globally raised. Coal is abundant in reserves and high in supply stability and economic efficiency. However, it is much in CO2 emission per calorific value. To control as much CO2 emission as possible, effective utilization such as increasing of power generation efficiency has been proceeded with. In addition to ultra supercritical pressure and fluidized bed combustion, cited are coal gasification combined cycle power generation and high temperature type fuel cell. Coal has 5-20% ash and impurities like sulfur/nitrogen. Coal should be used clean by pollution abatement measures such as dust collecting, desulfurization and denitrification. Japan is at a world top level of these technologies. Coal is solid, and therefore, is more difficult to handle than liquid fuel. To use it ...

1994-04-25

407

Research on development of adsorbent for separating and collecting light element isotopes  

International Nuclear Information System (INIS)

Lithium isotopes are used as the raw material of tritium which is the fuel for fusion power generation and the material for fusion reactors, accordingly those are indispensable for future nuclear fusion power generation. As for boron isotopes, the neutron absorption corss section is very large, therefore, they are used for shielding neutrons and controlling fast neutron reactors. In order to further develop the utilization of nuclear power, it is important to develop the technology for separating and refining light element isotopes in large amount. In fiscal year 1995, the relation of the ion sieve characteristics of inorganic ion exchanger and the behavior of lithium isotope separation was examined. The behavior of forming boron complex of polyol amine was examined by B-11 NMR. These experiments and the results are reported. It was shown to be feasible that lithium is adsorbed from ...

408

Railgun. Challenge to ultra-high speed; Railgun. Chokosoku eno chosen  

Energy Technology Data Exchange (ETDEWEB)

A railgun has an armature driven between two rail-like conductors. In other words, it is a linear drive device system that drives airframes by using the Lorentz`s force. The system is expected as a next-generation high-speed transport means, or as a means to create such ultimate fields as ultra-high pressures, ultra-high temperatures, and ultra-ferromagnetic fields. This paper is a report on investigations on the relevant technological trends as surveyed by the investigation committee at the Institute of Electrical Engineers of Japan using research reports published inside and outside the country. The reported themes cover explanations from the construction to the pulse power supply that forms the core of the technology, problems in switching, recent status of research and development, and to application fields. Compatibility in the high-level electrical and mechanical performances demanded in the railgun is not as easy as has been anticipated ...

1995-09-12

409

Nant-De-Chatillon: electric power generation by ORC (organic Rankine cycle) using waste heat from the Chatillon biogas plant; Nant-de-Chatillon: Production d'electricite par ORC a partir des rejets de chaleur du site de methanisation de Chatillon. Resume  

Energy Technology Data Exchange (ETDEWEB)

This report prepared for the Swiss Federal Office of Energy (SFOE) describes the practical realisation and testing of a heat recovery system based on a one-stage organic Rankine cycle with R134a as the working fluid. The waste heat has a temperature of 95 {sup o}C and originates from a gas engine that powers a small co-generation plant fuelled with biogas produced on-site. Two similar cycles have been built, ORC1 with one and ORC2 with two turbines. Only ORC1 has been tested so far. The maximum efficiency measured in these tests was 6.64% (theoretical Carnot-efficiency: 17 %) and the electric power output was 5.0 kW. The problems encountered during commissioning are described and recommendations for further improvements are given.

2005-07-01

410

Input of cogeneration units in the future Dutch electric power supply. Inzet van warmte/krachteenheden in de toekomstige Nederlandse elektriciteitsvoorziening  

Energy Technology Data Exchange (ETDEWEB)

An investigation was carried out to determine the significance of a large input of cogeneration units for the electric power generation, next to the input of coal and uranium. Thereto a production plant has been set up to generate heat and electric power. The plant serves as a basis for a number of comparative calculations: basic calculations to investigate the influence of some strategies on the cogeneration input, and sensitivity calculations to determine the influence of a few changes in the starting points. Some variants have been deduced from this plant, which is based on prognosis for the year 2000. By means of the computer calculation program OPINIE (Optimale Inzet en Instelling van Eenheden: Optimal Input and Installation of Units) the minimal variable costs were calculated for different situations. Finally for each considered situation the total annual costs have been calculated. 53 figs., 13 ...

1987-02-01

411

Fuel cycle options and sustainability for new nuclear build in the UK  

International Nuclear Information System (INIS)

After a long period of stagnation in the UK, Europe and the USA, there is now a real expectation that new nuclear plants will be under construction shortly. Several factors have contributed to this change of position in the UK: the growing realisation that effective action is needed to offset greenhouse gas emissions; higher prices for fossil fuels; increasing reliance on overseas supplies of oil and gas; the limitations of wind and wave power and distribution; security of supply; the gradual realisation in the deregulated electricity generation market that nuclear power is competitive and the pending closure of most of the UK's nuclear fleet within less than 15 years. All these factors have led to a reversal of the UK Government's attitude to nuclear power, which has now ruled in favour of allowing a new generation of nuclear plants being built. This paper summarises some of the ...

2008-09-14

412

Electric cars in the context of the environmental and energy problemacy. Elektrische auto's in het perspectief van de milieu- en energieproblematiek  

Energy Technology Data Exchange (ETDEWEB)

An analysis is given of the problems which can be solved by the use of electric-powered vehicles. A detailed comparison is made of the energy consumption and the air polluting emissions of electric and conventional vehicles, taking into account the energy consumption of the vehicles and the primary energy consumption of electric power generation and automotive fuels production. Also the air pollution, as a result of power generation and fuel production are considered. In chapter 1 an outline is given of the traffic and transportation sector in the Netherlands with special attention to data on the energy consumption and the air pollution of this sector. Based on these data the problems can be formulated for which the application of electric vehicles can be a solution. In chapter three a brief description is given of the technical specifications and characteristics of electric ...

1992-09-01

413

Cogeneration process for small and medium-sized industrial plants; CO-Generation-Process fuer kleinere und mittlere Industrieanlagen  

Energy Technology Data Exchange (ETDEWEB)

Industrial companies are being forced by increasingly restrictive environmental legislation to implement power station technology which is environmentally compatible and which conserves scarce resources. Gas and steam turbine power stations have been causing a sensation in this field for some time. This article gives an introduction to gas and steam turbine power stations in the 4 MW to 30 MW size range. The designs of the plants described here not only provide for electricity generation by gas and steam turbines however, but also designs specific to particular companies for process steam and district heating supply. (orig.) [Deutsch] Durch immer restriktivere Umweltschutzgesetze werden die Industrieunternehmen zu einer umwelt- und ressourcenschonenden Kraftwerkstechnik gedraengt. Auf diesem Gebiet sorgen nun seit geraumer Zeit GuD-Kraftwerke fuer Furore. In diesem Beitrag werden GuD-Kraftwerke in einer ...

1993-12-31

414

Coal quality engineering analysis aids plant performance  

Energy Technology Data Exchange (ETDEWEB)

The Coal Quality Engineering Analysis (CQEA) program developed by the New York State Electric and Gas Company (NYSEC) calculates the as-burned cost of burning a specific coal in a specific generation unit. These costs include: maintenance costs for coal and ash handling equipment; ash disposal costs; cost of oil (if required for flame stability and/or derating because of pulverizer capacity limitation); flue gas desulfurization costs; cost of replacement power caused by pulverizer, precipitator fly ash collection and bottom ash capacity limitation; boiler losses due to moisture, hydrogen, dry gas and unburned carbon; power for coal and ash handling equipment; power for coal pulverizers; cost of using excess air to prevent slagging of coal with low ash softening temperatures; and effect of heat rate on coal tonnage required for a desired generation. The use of CQEA to identify areas ...

1988-10-01

415

Materials for power sources to meet military requirements  

Energy Technology Data Exchange (ETDEWEB)

Power source requirements for the military were presented to provide guidelines for research and development planning. Power sources that contain a high amount of energy and are small, light and durable are a common request from military users. Safety, reliability and low temperature performance are also important factors in the selection of power sources, as are cost and energy efficiency. Issues concerning advanced batteries were reviewed with reference to high energy density cathode materials. Various thermoelectric and renewable energy materials were discussed, with reference to recovery and conversion of waste heat. It was suggested that photovoltaic devices could help revolutionize military logistics by modifying energy re-supply requirements. Solid Oxide Fuel Cells (SOFC) were considered in relation to the high price of the ceramic materials required for operation. It was noted that the development of SOFC anodes ...

2005-07-01

416

A study on the management of spent fuel storage capacity in South Korea  

International Nuclear Information System (INIS)

The saturation of South Korea's at-reactor (AR) spent fuel storage pools will create a necessity for additional spent fuel storage capacity. Because the South Korean government has the plan to increase the number of nuclear power plants from 20 units (end of 2005) to 27 units by 2015, the increase of spent nuclear fuel generation will be accelerated. Because there is no clear national plan for spent nuclear fuel storage and disposal, the utility company (Korea Hydraulic Nuclear Power company) is planning to construct a spent fuel storage facility with 11 000 tHM capacity for Pressurised Water Reactor (PWR). This study is intended to predict the maximum allowable periods when the storage facility will be fully occupied with respect to the already fixed re-racking plan of spent fuel storage pools and construction of new nuclear power plants. The result from this study will be used as fundamental data for ...

2006-06-19

417

q-Virasoro algebra, q-conformal dimensions and free q-superstring  

International Nuclear Information System (INIS)

The commutators of standard Virasoro generators and fields generate various representations of the centreless Virasoro algebra depending on a conformal dimension J of the field in question (J is related to the Bargmann index of SU(1,1) generated by L_m, m=0,#+-#1). We introduce the notion of q-conformal dimension for various oscillator realizations of q-deformed Virasoro (super)algebras proposed earlier. We use the field theoretical approach introduced recently in which the q-Virasoro currents L"#alpha# (z) are expressed as Schwinger-like point-split normally ordered quadratic expressions in elementary fields. We extend this approach and probe the elementary fields A(z) (the q-superstring coordinate, momentum and fermionic field) and their powers by the q-Virasoro generators L"#alpha#_m (i.e. we calculate the commutators [L"#alpha#_m,A(z)]) and show that to all of them can be ...

1996-12-01

418

Internalizing externalities of electricity generation: An analysis with MESSAGE-MACRO  

Energy Technology Data Exchange (ETDEWEB)

This paper examines the global impacts of a policy that internalizes the external costs (related to air pollution damage, excluding climate costs) of electricity generation using a combined energy systems and macroeconomic model. Starting point are estimates of the monetary damage costs for SO{sub 2}, NO {sub X} , and PM per kWh electricity generated, taking into account the fuel type, sulfur content, removal technology, generation efficiency, and population density. Internalizing these externalities implies that clean and advanced technologies increase their share in global electricity production. Particularly, advanced coal power plants, natural gas combined cycles, natural gas fuel cells, wind and biomass technologies gain significant market shares at the expense of traditional coal- and gas-fired plants. Global carbon dioxide emissions are lowered by 3% to 5%. Sulfur dioxide emissions drop ...

2007-02-15

419

Internalizing externalities of electricity generation: An analysis with MESSAGE-MACRO  

Energy Technology Data Exchange (ETDEWEB)

This paper examines the global impacts of a policy that internalizes the external costs (related to air pollution damage, excluding climate costs) of electricity generation using a combined energy systems and macroeconomic model. Starting point are estimates of the monetary damage costs for SO{sub 2}, NOX, and PM per kWh electricity generated, taking into account the fuel type, sulfur content, removal technology, generation efficiency, and population density. Internalizing these externalities implies that clean and advanced technologies increase their share in global electricity production. Particularly, advanced coal power plants, natural gas combined cycles, natural gas fuel cells, wind and biomass technologies gain significant market shares at the expense of traditional coal- and gas-fired plants. Global carbon dioxide emissions are lowered by 3% to 5%. Sulfur dioxide emissions drop significantly ...

2007-02-15

420

Flow induced vibration mock-up test for heat exchanger tubes of PWR steam generator  

International Nuclear Information System (INIS)

It is one of the most important subjects to estimate the flow-related stability of the heat exchanger tubes. A large scale model steam generator has been developed to verify the stability of the tubes in the Japanese PWR steam generators for the two-phase flow-induced vibration and to accumulate related technical data of thermal-hydraulic and flow-induced vibration of U-bend tube bundle. The model steam generator has 230 U-bend tubes of 46 different radius and 5 columns for each of practical diameter and material, and the anti vibration bars are inserted into each spacing between tube arrays. The freon R123 has been used as the secondary side fluid in stead of water-steam two-phase. In the test, void fraction and interfacial velocities in U-bend and straight tube-bundle are measured with bi-optical probes, and vibration responses of some selected tubes are measured with strain gauges and accelerators. It is verified that ...

2000-10-01

421

Electrochemical power generation apparatus and methods  

Energy Technology Data Exchange (ETDEWEB)

Apparatus and methods are described for generating heat and electricity from the consumption of a variety of aluminum products. The method consists of (A) a reaction chamber containing an aqueous electrolyte solution and adapted for introduction therein of aluminum pieces of various shapes and sizes up to a certain maximum predetermined size and for effecting a chemical reaction between said aqueous electrolyte and said aluminum pieces yielding aluminum hydroxide and an intermediate reactant; (B) means for feeding said aluminum pieces into said reaction chamber in small quantities upon demand; (C) means for removing the heat generated in said chamber as a result of said reaction; (D) means for removing said aluminum hydroxide reaction product; and (E) means for oxidizing said intermediate reactant in an electrochemical cell, thereby generating electrical energy. The intermediate reactant is preferably hydrogen or zinc. The ...

1981-03-03

422

Electrochemical power generation  

Energy Technology Data Exchange (ETDEWEB)

Apparatus and methods for generating heat and electricity from the consumption of a variety of aluminum products comprise: (A) a reaction chamber containing an aqueous electrolyte solution and adapted for introduction therein of aluminum pieces of various shapes and sizes up to a certain maximum predetermined size and for effecting a chemical reaction between said aqueous electrolyte and said aluminum pieces yielding aluminum hydroxide and an intermediate reactant; (B) means for feeding said aluminum pieces into said reaction chamber in small quantities upon demand; (C) means for removing the heat generated in said chamber as a result of said reaction; (D) means for removing said aluminum hydroxide reaction product; and (E) means for oxidizing said intermediate reactant in an electrochemical cell, thereby generating electrical energy. The intermediate reactant is preferably hydrogen or zinc. The latter may be used in a ...

1983-01-18

423

Development and validation of steam generator models for thermal performance monitoring  

International Nuclear Information System (INIS)

The thermal performance monitoring and optimization system TEMPO is developed at the OECD Halden Reactor Project. The system supports staff of nuclear power plants in identification and correction of problems, which cause small decreases in plant efficiency but which may lead to significant economical losses. The system-wide physical model consists of mathematical description of individual components, such as the reactor, the pumps, the heat exchangers, or the turbines, etc. TEMPO code has recently been extended with new steam generator (SG) models. The present paper summarizes the thermal-hydraulic modelling aspects of the vertical and the horizontal SG. The heat balance equations and their solution are shown with the appropriate initial and boundary conditions. The method of the calculation of the pressure losses are also introduced. The vertical SG model is based on a U-tube structure and treated as a 1D flow channel. The horizontal approach ...

2003-04-20

424

Conversion of the Midland nuclear station  

Energy Technology Data Exchange (ETDEWEB)

The authors report how the Midland cogeneration venture (MCV) is repowering the incomplete Midland nuclear plant to operate as a gas-fired combined cycle cogeneration facility. They discuss how their company is responsible for performing engineering, procurement, licensing, construction, start-up, training, and operational assistance for this facility. As shown, twelve gas turbine generator sets supply heat to twelve heat recovery steam generators (HRSGs), which are headered together on the steam side to provide energy to either of two existing steam turbine generators. This combination of equipment enables approximately 1,380 MWe of electrical generation capability, while supplying an average steam flow of 629,000 lbs/hr to an adjacent Dow Chemical Company pant. The MCV facility will also provide 60 MW of electric power to Dow. The authors report how the Midland ccogeneration ...

1988-01-01

425

The integration of renewable energy sources into electric power transmission systems  

Energy Technology Data Exchange (ETDEWEB)

Renewable energy technologies such as photovoltaics, solar thermal power plants, and wind turbines are nonconventional, environmentally attractive sources of energy that can be considered for electric power generation. Many of the areas with abundant renewable energy resources (very sunny or windy areas) are far removed from major load centers. Although electrical power can be transmitted over long distances of many hundreds of miles through high-voltage transmission lines, power transmission systems often operate near their limits with little excess capacity for new generation sources. This study assesses the available capacity of transmission systems in designated abundant renewable energy resource regions and identifies the requirements for high-capacity plant integration in selected cases. In general, about 50 MW of power from renewable ...

1995-07-01

426

Fuzzy coordination of multi-objectives reflecting the operator's intention for dynamic generation rescheduling [of power systems  

Energy Technology Data Exchange (ETDEWEB)

This paper proposes a novel and efficient algorithm to obtain optimal generation dispatch reflecting the operator's intention in power system rescheduling. In optimal system operation, various objectives, such as economy, quality and transmission security, need to be achieved simultaneously. However, these objectives are often contradictory and in a trade-off relationship with respect to each other thus making it difficult to handle this class of problem by conventional approaches. In the proposed algorithm, optimal generation dispatch is formulated as a multi-objective optimization problem. A fuzzy coordination technique based on fuzzy set theory is used to obtain an optimal solution. Evaluation indices composed of fuel cost, transmission line overload and AFC regulation capacity margin are measured by the membership functions, and multi-objective optimization is solved by maximizing the composite performance ...

1992-10-01

427

Performance test of a small compact combined heating and electricity generating plant; Erfolgskontrolle Klein-Blockheizkraftwerk  

Energy Technology Data Exchange (ETDEWEB)

The present project examined the operating characteristics and application possibilities of a new, compact combined heating and electricity generating unit with a thermal output of 14,5 kW and a generating capacity of 5,5 kW. Such a module was installed in a plant in Arlesheim (Canton of Basel-Country) and subject to performance measurements. The small heating and generating plant is designed for cyclic operation (without heat storage) and is very compact and low in cost. The heating and generating unit conforms to all Swiss regulations relating to electrical installations and air pollution control. The NO{sub x} emissions of the unit (400 mg/m{sup 3} in steady state operation) are above the limits of LRV 92 (80 mg/m{sup 3}), but the regulation does not apply for units in this power range. The electricity generation costs are approximately CHF 0.16/kWh. It ...

1995-12-01

428

Development of Program Evaluating the Effects on the Secondary Side of Steam Generator due to Foreign Objects  

Energy Technology Data Exchange (ETDEWEB)

When materials such as metal are into the secondary side of steam generator, they, so called foreign objects, may have influences on the integrity of the steam generator tubes. They cause the tube wear due to the relative motion between the tubes and foreign objects and the tube impact due to flow. The best way to avoid the effects is to remove all the foreign objects. However, it is not easy to remove the foreign materials thoroughly due to their condition such as the location. If the locations of the foreign materials are in the middle of tube bundle and the tube arrangement of the steam generator is the triangle type, the equipment such as FOSAR(Foreign Object Search and Retrieval) can not reach their locations. If the foreign materials stick together with the tubes or tube sheet, they can not be removed. In the case of operating the steam generator with the foreign materials, the licensee must prove ...

2005-07-01

429

Development of Program Evaluating the Effects on the Secondary Side of Steam Generator due to Foreign Objects  

International Nuclear Information System (INIS)

When materials such as metal are into the secondary side of steam generator, they, so called foreign objects, may have influences on the integrity of the steam generator tubes. They cause the tube wear due to the relative motion between the tubes and foreign objects and the tube impact due to flow. The best way to avoid the effects is to remove all the foreign objects. However, it is not easy to remove the foreign materials thoroughly due to their condition such as the location. If the locations of the foreign materials are in the middle of tube bundle and the tube arrangement of the steam generator is the triangle type, the equipment such as FOSAR(Foreign Object Search and Retrieval) can not reach their locations. If the foreign materials stick together with the tubes or tube sheet, they can not be removed. In the case of operating the steam generator with the foreign materials, the licensee must prove ...

2005-10-27

430

Feasibility study on the demonstrative test on the hybrid mini hydroelectric power generation technology. 2; Hybrid gata mini suiryoku hatsuden gijutsu ni kakawaru jissho shiken kanosei chosa. 2  

Energy Technology Data Exchange (ETDEWEB)

A study was made for the purpose of electrification of unelectrified zones of the mountainous areas in developing countries using extremely small hydroelectric power facilities. The target for this project is a development of a micro hydroelectric power system with a size of about 5kW, which is estimated regarding that 1 village has 80 houses and each house needs electricity of 60W. In the study, the low-head system using a weir of irrigation channels in Subang pref. of West Java state was selected by the evaluation of access, stability of flow rate, natural conditions, etc. The hydroelectric power plant is of a flow-in method in which water is taken from the left bank and is injected/discharged to the downstream of the left bank. As the hybrid complementary power source, hybrid battery with a two-hour charging time at peak and a capacity of 3.5kWh was considered. When estimating the construction cost ...

1996-03-01

431

Optimal capacity of the battery energy storage system in a power system  

Energy Technology Data Exchange (ETDEWEB)

Due to the cyclical human life, utility loads appear to be cyclical too. During daytime when most factories are in operation, the electricity demand is very high. On the contrary, when most people are sleeping from midnight to daybreak, the electric load is very low, usually only half of the peak load amount. To meet this large gap between peak load and light load, utilities must idle many generation plants during light load period while operating all generation plants during peak load period no matter how expensive they are. This low utilization factor of generation plants and uneconomical operation have sparked utilities to invest in energy storage devices such as pumped storage plants, compressed air energy storage plants, battery energy storage systems (BES) and superconducting magnetic energy storage systems (SMES) etc. Among these, pumped storage is already commercialized and is the most widely used device. However, ...

1993-12-01

433

Large lignite steam generators with circulating fluidized bed combustion. Operating experience with a 290 t/h and 400 t/h plant in the RWE power station at Goldenberg; Grosse Braunkohle-Dampferzeuger mit zirkulierender Wirbelschichtfeuerung. Betriebserfahrungen aus der 290 t/h- und der 400 t/h-Anlage im Kraftwerk Goldenberg der RWE Energie AG  

Energy Technology Data Exchange (ETDEWEB)

Early in 1988 RWE decided to overhaul the power station at Goldenberg. This was necessary due to the age of the plant, the obligation to supply heat and process steam and recent amendments of environmental legislation. After analysing demands and needs one developed a plant concept with a 290 t/h and a 400 t/h steam generator. Due to lack of space the decision was made in favour of a circulating atmospheric fluidised bed combustion instead of steam generators with pulverised lignite combustion as these steam generators take up much more space due to the legally required desulphurisation plants for gaseous emissions. Apart from generating steam RWE wishes to gain experience with this combustion technology and test it for suitability and use in large-scale plant. (orig./KO) [Deutsch] Aufgrund des fortgeschrittenen Alters, der aktuellen Umweltschutzgesetzgebung sowie bestehender ...

1995-12-31

434

A study on the regulatory approach of KNGR multiple failure events  

Energy Technology Data Exchange (ETDEWEB)

This project is to provide the regulatory direction of containment bypass during multiple steam generator tube failure issue for the Korean Next Generation Reactors, which is a part of major technical issues resulted from the safety regulation R and D on the KNGR. The outstanding results are as follows : the Multiple Steam Generator Tube Repture(MSGTR) event has never been occurred in the history of commercial nuclear reactor operation but single Steam Generator Tube Rupture(SGTR) event is reported to occur every two years. A probabilistic safety analysis study on MSGTR event, however, show its probability of occurrence is to be the same order as the design basis accidents such as LACA. In this regard, the ability of NPPs to cope with MSGTR event is required. Some requirements on initial and boundary conditions are suggested to be used in the analyses of NPPs during MSGTR events. The items that should ...

2001-01-15

435

Sustainably economical operation of pumped storage power plants in a prospective market environment with increasing renewable energy generation; Nachhaltig wirtschaftlicher Einsatz von Pumpspeicherkraftwerken. Im zukuenftigen Marktumfeld mit steigender regenerativer Erzeugung  

Energy Technology Data Exchange (ETDEWEB)

Pumped storage plants participate in two structurally different markets: the market for scheduled energy (also known as spot market) and the reserve market. In order to achieve the best possible plant scheduling in terms of revenues the marketing of the available capacity from pumped storage plants needs to be optimised in both markets. Moreover, due to the abilities for providing reserve, pumped storage capacities within an existing power plant portfolio can lead to synergies for the whole portfolio. The optimised combined participation of a power plant in both spot and reserve market as well as the coherent portfolio effect are considered as particular challenges in energy economic assessments, e.g. in the light of investment decisions. Based on an extension project and in cooperation with RWTH Aachen University an optimised combined participation of a power plant in both markets was simulated for the first time, thereby ...

2010-07-01

436

Storing hydroelectricity to meet peak-hour demand  

Energy Technology Data Exchange (ETDEWEB)

This paper reports on pumped storage plants which have become an effective way for some utility companies that derive power from hydroelectric facilities to economically store baseload energy during off-peak hours for use during peak hourly demands. According to the Electric Power Research Institute (EPRI) in Palo Alto, Calif., 36 of these plants provide approximately 20 gigawatts, or about 3 percent of U.S. generating capacity. During peak-demand periods, utilities are often stretched beyond their capacity to provide power and must therefore purchase it from neighboring utilities. Building new baseload power plants, typically nuclear or coal-fired facilities that run 24 hours per day seven days a week, is expensive, about $1500 per kilowatt, according to Robert Schainker, program manager for energy storage at the EPRI. Schainker the that building peaking plants at $400 per ...

1992-04-01

437

Storing hydroelectricity to meet peak-hour demand  

International Nuclear Information System (INIS)

This paper reports on pumped storage plants which have become an effective way for some utility companies that derive power from hydroelectric facilities to economically store baseload energy during off-peak hours for use during peak hourly demands. According to the Electric Power Research Institute (EPRI) in Palo Alto, Calif., 36 of these plants provide approximately 20 gigawatts, or about 3 percent of U.S. generating capacity. During peak-demand periods, utilities are often stretched beyond their capacity to provide power and must therefore purchase it from neighboring utilities. Building new baseload power plants, typically nuclear or coal-fired facilities that run 24 hours per day seven days a week, is expensive, about $1500 per kilowatt, according to Robert Schainker, program manager for energy storage at the EPRI. Schainker the that building peaking plants at $400 per ...

1992-01-01

438

Results of third regular inspection of No. 2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co. , Inc  

Energy Technology Data Exchange (ETDEWEB)

The third regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from December 27, 1988 to May 25, 1989. The parallel operation was resumed on April 28, 1989, 123 days after the parallel off. The facilities which were the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation and emergency electric power generation system. On the facilities which were the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out. As the results, significant in indication was observed in 8 bolts for fixing the flow-changing vanes of primary coolant pumps, and broken valve spindles were found, but other abnormality was not found. The works related to this regular inspection were accomplished within the range of ...

1990-03-01

439

Results of second regular inspection of No.2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc  

International Nuclear Information System (INIS)

The second regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from October 5, 1987 to January 8, 1988. the parallel operation was resumed on December 8, 1987, 65 days after the parallel off. The facilities as the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation, and emergency power generation system. On these facilities as the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out, and abnormality was not found at all. The works related to this regular inspection were accomplished within the range of allowable dose based on the relevant laws. The main reconstruction works carried out during the period of this regular inspection were the change of the degree of enrichment from 3.15 ...

1988-01-01

440

Results of second regular inspection of No. 2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co. , Inc  

Energy Technology Data Exchange (ETDEWEB)

The second regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from October 5, 1987 to January 8, 1988. the parallel operation was resumed on December 8, 1987, 65 days after the parallel off. The facilities as the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation, and emergency power generation system. On these facilities as the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out, and abnormality was not found at all. The works related to this regular inspection were accomplished within the range of allowable dose based on the relevant laws. The main reconstruction works carried out during the period of this regular inspection were the change of the degree of enrichment from 3.15 ...

1988-08-01

441

Radio Frequency Plasma Applications for Space Propulsion  

Energy Technology Data Exchange (ETDEWEB)

Recent developments in solid-state radio frequency (RF) power technologies allow for the practical consideration of RF heated plasmas for space propulsion. These technologies permit the use of any electrical power source, de-couple the power and propellant sources, and allow for the effcient use of both the propellant mass and power. Effcient use of the propellant is obtained by expelling the rocket exhaust at the highest possible velocity, which can be orders of magnitude higher than those achieved in chemical rockets. Handling the hot plasma exhaust requires the use of magnetic nozzles, and the basic physics of ion detachment from the magnetic eld is discussed. The plasma can be generated by RF using helicon waves to heat electrons. Further direct heating of the ions helps to reduce the line radiation losses, and the magnetic geometry is tailored to allow ion cyclotron resonance ...

1999-09-13

442

Proton exchange membrane fuel cells for distributed power generation  

Energy Technology Data Exchange (ETDEWEB)

H Power Enterprises of Canada was founded in 1997; currently, it has 40 employees and expect to grow to about 50 by mid-2000. The company is engaged in fuel cell technology development , manufacturing and marketing. The company has the advantage that its technology has been proven, products are already commercialized, and strategic alliances are already in place to make an assault on the market. The concept of proton exchange membrane fuel cell technology is explained in terms of efficiency, response time, power density, stack manufacturing cost, maintenance cost, stack life and compatible thermal loads. Individual products, their energy and operating efficiency, potential applications and potential markets are reviewed. It is estimated that for stationary fuel cells the market will be worth $ 30 billion by 2030. In the United States alone, remote residential cogeneration sites are estimated at 500,000. The estimates for uses in transportation ...

2000-07-01

443

Power Systems Development Facility Gasification Test Campaign TC17  

Energy Technology Data Exchange (ETDEWEB)

In support of technology development to utilize coal for efficient, affordable, and environmentally clean power generation, the Power Systems Development Facility (PSDF) located in Wilsonville, Alabama, routinely demonstrates gasification technologies using various types of coals. The PSDF is an engineering scale demonstration of key features of advanced coal-fired power systems, including a KBR (formerly Kellogg Brown & Root) Transport Gasifier, a hot gas particulate control device, advanced syngas cleanup systems, and high-pressure solids handling systems. This report summarizes the results gasification operation with Illinois Basin bituminous coal in PSDF test campaign TC17. The test campaign was completed from October 25, 2004, to November 18, 2004. System startup and initial operation was accomplished with Powder River Basin (PRB) subbituminous coal, and then the system was transitioned to ...

2004-11-30

444

Playing the money game  

Energy Technology Data Exchange (ETDEWEB)

Conventional methods of financing power generation, transmission and distribution in India cannot keep pace with the ever-growing demand. Alternative methods are discussed. Given the vast growth potential, funding can be by equity or debt capital or a hybrid of these. There is an urgent necessity to develop local capital markets as a source of funds since there are limits to how much can be derived from foreign investors, multilaterals and export credit agencies. The domestic financial institutions have raised large amounts for private investment in other sectors. With the creation of a proper climate and power companies set up with an attractive rate of return, sufficient capital could be forthcoming from both domestic and external markets for the power sector. In other sectors, Indian companies have been able to attract investment through Global Depository Receipts and Euroconvertible Bonds, for ...

1997-01-01

445

Performances of a lithium-carbon ``lithium ion``battery for electric powered vehicle; Performances d`un accumulateur au lithium-carbone ``Lithium Ion`` pour vehicule electrique  

Energy Technology Data Exchange (ETDEWEB)

The lithium battery, also called `lithium-carbon` or `lithium ion`, is today the most promising candidate that can reach the expected minimum traction performances of electric powered vehicles. Thanks to a more than 20 years experience on lithium generators and to a specific research program on lithium batteries, the SAFT company has developed a 100 Ah electrochemical system, and full-scale prototypes have been manufactured for this application. These prototypes use the Li{sub x}NiO{sub 2} lithiated graphite electrochemical pair and were tested in terms of their electrical performances. Energy characteristics of 125 Wh/kg and 265 Wh/dm{sup 3} could be obtained. The possibility of supplying a power greater than 200 W/kg, even at low temperature (-10 deg. C) has been demonstrated with these elements. A full battery set of about 20 kWh was built and its evaluation is in progress. It comprises the electronic control systems for ...

1996-12-31

446

Nuclear reactor closed Brayton cycle power conversion system optimization trends for extra-terrestrial applications  

International Nuclear Information System (INIS)

Extra-terrestrial exploration and development missions of the next century will require reliable, low-mass power generation modules of 100 kW_e and more. These modules will be required to support both fixed-base and manned rover/explorer power needs. Low insolation levels at and beyond Mars and long periods of darkness on the moon make solar conversion less desirable for surface missions. For these missions, a closed Brayton cycle energy conversion system coupled with a reactor heat source is a very attractive approach. The authors conducted parametric studies to assess optimized system design trends for nuclear-Brayton systems as a function of operating environment and user requirements. The inherent design flexibility of the closed Brayton cycle energy conversion system permits ready adaptation of the system to future design constraints. This paper describes a dramatic contrast between system designs requiring man-rated ...

1990-08-12

447

Free-electron laser beam  

International Nuclear Information System (INIS)

The principle and history of free-electron laser (FEL), first evidenced in 1977, the relationship between FEL wavelength and output power, the high-power FEL driven by the superconducting linac, the X-ray FEL by the linac, and the medical use are described. FEL is the vacuum oscillator tube and essentially composed from the high-energy linac, undulator and light-resonator. It utilizes free electrons in the vacuum to generate the beam with wavelength ranging from microwave to gamma ray. The first high-power FEL developed in Japanese Atomic Energy Research Institute (JAERI) is based on the development of superconducting linac for oscillating the highest power beam. In the medical field, applications to excise brain tumors (in US) and to reconstruct experimentally blood vessels in the pig heart (in Gunma University) by lasing and laser coagulator are in progress with examinations to ...

2003-06-01

448

Exploring research of factors affecting public acceptance of nuclear energy. Result of a survey at Suginami ward, Tokyo  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this research is to clarify how psychological factor's impact on public acceptance of nuclear energy varies with people's degree of knowledge. For this purpose, we carried out questionnaire survey about nuclear energy at Suginami ward, Tokyo. After collecting data, we applied factor analysis to the data, and found 4 factors: Trust in the Authorities, Superiority of Nuclear Power Generation, Benefit for Nuclear Power Plants' Siting Areas, and Risk Perception about Nuclear Technology. In addition, using multiple regression analysis, we evaluated the impact of the 4 factors on 2 issues: the decision for or against nuclear policy and the reaction to nuclear power plant siting. Consequently, we found the change of impact of all 4 factors on the 2 issues. Especially, the impact of the 4 factors to the reaction to nuclear power plant siting was ...

2003-03-01

449

Exploring research of factors affecting public acceptance of nuclear energy. Result of a survey at Suginami ward, Tokyo  

International Nuclear Information System (INIS)

The purpose of this research is to clarify how psychological factor's impact on public acceptance of nuclear energy varies with people's degree of knowledge. For this purpose, we carried out questionnaire survey about nuclear energy at Suginami ward, Tokyo. After collecting data, we applied factor analysis to the data, and found 4 factors: Trust in the Authorities, Superiority of Nuclear Power Generation, Benefit for Nuclear Power Plants' Siting Areas, and Risk Perception about Nuclear Technology. In addition, using multiple regression analysis, we evaluated the impact of the 4 factors on 2 issues: the decision for or against nuclear policy and the reaction to nuclear power plant siting. Consequently, we found the change of impact of all 4 factors on the 2 issues. Especially, the impact of the 4 factors to the reaction to nuclear power plant siting was drastically changed by ...

2003-03-01

450

Dynamic security assessment in electric power systems  

Energy Technology Data Exchange (ETDEWEB)

A new approach to dynamic security assessment in electric power systems is proposed. A power system is modeled as a dynamical system with random variable structure. Structural variations are caused by primary and secondary events. Primary events are state-independent disturbances representing line and unit faults and load changes and are modeled by random jump processes. Secondary events that represent forced line and unit outages and load sheddings are modeled through an aggregate representation of the protection system as random processes whose change in time corresponds to the crossing of switching surfaces by the state process. These switching surfaces are defined by the setting of the protective relays. Commensurate with this model a three-state decomposition of the operating conditions into normal, emergency, and partial load operating states is suggested. Transitions between these states are described in terms of set-valued mappings in ...

1983-01-01

451

Advanced hydraulic power shovels for surface mines. Sovremennye kar'ernye gidravlicheskie odnokovshovye ehkskavatory  

Energy Technology Data Exchange (ETDEWEB)

Reviews types of hydraulic power shovels used in coal surface mines in the USA, FRG, Japan and other countries. Excavators of the first, second and third generation are compared. Hydraulic schemes of the excavators are compared. The following excavators are reviewed: the RH-75, RH-75C, 1000 SK, H-801, RC-1500, H-185, EX-1800, R-994, RH-120C, H-241, Marion 3560, H-285, EX-3500, H-485, RH-300. The following parameters are compared: mass, price, digging range, digging power, productivity, motors, travelling speed, availability coefficient, pressure in the hydraulic systems, control systems. The following elements are discussed: schemes of hydraulic drives, main motors and engines, pump stations, hydraulic equipment, hydraulic accumulators, systems for cleaning and cooling hydraulic fluids, control systems, working fluids. Reliability of hydraulic power shovels and factors that influence reliability are ...

1989-01-01

452

A corporate social responsibility initiative in the field of nuclear power  

International Nuclear Information System (INIS)

Societatea Nationala Nuclearelectrica SA is the operator of the Cernavoda nuclear power plant and the second largest energy producer in Romania, after Hidroelectrica, ensuring 18% of the internal energy demand. The production of nuclear power differs from other industrial activities through the risks it involves and through the legacy it leaves to the future generations, i.e. the nuclear waste. Taking into account these considerations, public acceptance represents a constant preoccupation for nuclear companies around the world. Corporate Social Responsibility (CSR) is a new practice in the nuclear industry. After a long tradition of involvement in the life of the local community through the Social Program for Cernavoda, Nuclearelectrica has initiated a CSR campaign with the theme 'Welcome a tree in your family', addressed to pupils and high school students from Cernavoda. By this campaign, we aimed at creating relevance, ...

2009-10-12

453

Thermal hydraulic analysis of nuclear reactors (THEA). THEA summary report  

Energy Technology Data Exchange (ETDEWEB)

The project is focused on the thermal hydraulic analyses of nuclear power plants. Specific areas of research have been the modelling of heat transfer in horizontal steam generator in presence of non-condensable gas, and the development of tools for multidimensional two-phase flow simulations. The effect of non-condensable gas on the heat transfer in the horizontal steam generator (SG) has been studied by calculating with APROS the PACTEL experiments NCG-1 (air injection) and NCG-3 (helium injection). The work done for the two-phase flow model development consists of two parts; improving the solution algorithm of porous media code PORFLO, and adding a homogeneous two-phase model to the commercial CFD code Fluent. (orig.)

2004-07-01

454

Plasma ignition and stabilization of combustion of anthracite culm from the Donbass  

Energy Technology Data Exchange (ETDEWEB)

From 1965 to 1980 ash content in anthracite from the Donbass supplied to power plants increased from 21.9 to 35.5%, moisture content increased from 7.6 to 10.1%, calorific value declined from 23.7 to 18.5 MJ/kg. Combustion of anthracite culm is stabilized by mazout combustion. Heat treatment of anthracite culm by means of plasma generators improves fuel quality. High temperature causes emission of volatile matter from anthracite and partial gasification of coke particles. Combustion of volatile matter from anthracite and coke is a reliable ignition method for anthracite culm. It also stabilizes combustion of pulverized anthracite. Heat treatment of about 20% anthracite by plasma generators reduces nitrogen oxide emission from a furnace by 30-40%. 5 refs.

1990-01-01

455

Modelling of two-phase natural circulation in a WWER-plant: PMK experimental results  

International Nuclear Information System (INIS)

Experiments have been performed with the PMK integral-type facility, a model of WWER-440 type PWRs, to investigate two-phase natural circulation behaviour. The phenomena to be expected in this reactor type are different from those in PWRs with vertical steam generators mainly due to the loop seal in the hot leg and the horizontal layout of the steam generator heat transfer tubes. The experiments showed that the system is repressurized when the water level drops to the hot leg elevation due to the effect of the loop seal. Opening of the loop seal can be smooth, but may lead to oscillations depending on the power and the mass inventory. Natural circulation recovers after the hot leg loop seal is opened, but then decreases with further mass inventory decrease. (orig.).

456

Infrared (IR) vs x-ray power generation in the SLAC Linac Coherent Light Source (LCLS)  

Energy Technology Data Exchange (ETDEWEB)

The LCLS, a Free-Electron Laser (FEL) designed for operation at a first harmonic energy of 300 eV ({lambda} {congruent} 40{Angstrom}) in the Self-Amplified Spontaneous Emission (SASE) regime, will utilize electron bunches compressed down to durations of <0.5ps, or lengths of <150 {mu}. It is natural to inquire whether coherent radiation of this (and longer) wavelength will constitute a significant component of the total coherent output of the FEL. In this paper a determination of a simple upper bound on the IR that can be generated by the compressed bunches is outlines. Under the assumed operating parameters of the LCLS undulator, it is shown that that IR component of the coherent output should be strongly dominated by the x-ray component.

1993-05-01

457

Influence of feed water distribution pipe replacement on the water chemistry in the steam generator at Loviisa NPP  

International Nuclear Information System (INIS)

Imatran Voima Oy , (IVO) operates two Russian designed nuclear power plants of type VVER440/213. Unit 1 has been operating since 1977 and unit 2 since 1981. First damage of feed water distribution (FWD) pipes was observed in 1989. In closer examinations FWD-pipe T-connection and distribution nozzles suffered from severe erosion corrosion damage. Similar damages have been found also in other VVER-440 type NPPs. In 1994 the first FWD-pipe was replaced by a new design mounted over the tube bundle instead of the old FWD-pipe, which was located inside the tube bundle. The purpose of this paper is to describe the new FWD-pipe and discuss its effects on the steam generator chemistry. (author)

1998-06-01

458

High temperature electrochemical polishing of H{sub 2}S from coal gasification process streams. Quarterly progress report, July 1, 1995--September 30, 1995  

Energy Technology Data Exchange (ETDEWEB)

Coal may be used to generate electrical energy by any of several processes, most of which involve combustion or gasification. Combustion in a coal-fired boiler and power generation using a steam-cycle is the conventional conversion method; however total energy conversion efficiencies for this type of process are only slightly over 30%. Integration of a gas-cycle in the process (combined cycle) may increase the total conversion efficiency to 40%. Conversion processes based on gasification offer efficiencies above 50%. H{sub 2}S is the predominant gaseous contaminant in raw coal gas. This process is concerned with the removal of H{sub 2} from coal gas through an electrochemical membrane technology.

1996-03-01

459

Grid Connections, Batteries, and On-Board Generation: Sources for Electric Traction  

British Library Electronic Table of Contents (United Kingdom)

Well over 90 percent of all motorized transportation is fueled by products of petroleum, but the end of such widespread use of oil may be in sight. Among alternative fuels for land transportation, electricity appears to be the most promising, in part because it can be renewably produced and readily transmitted. The inadequacy and high cost of on-board storage of electrical energy present major challenges to widespread deployment of electric traction, and may do so for many years. On-board generation of electrical energy also presents challenges. The third means of powering electric traction is to provide for connection to the electricity grid while in motion. Grid-connected vehicles (GCVs) are an established feature of many cities and of much inter-city transportation, chiefly as electric ...

2010-01-01

460

Economic comparison of clean coal generating technologies with natural gas-combined cycle systems  

International Nuclear Information System (INIS)

This paper reports that there are four combustion technologies upon which U.S. electric utilities are expected to rely for the majority of their future power generating needs. These technologies are pulverized coal- fired combustion (PC); coal-fired fluidized bed combustion (AFBC); coal gasification, combined cycle systems (CGCC); and natural gas-fired combined cycle systems (NGCC). The engineering and economic parameters which affect the choice of a technology include capital costs, operating and maintenance costs, fuel costs, construction schedule, process risk, environmental and site impacts, fuel efficiency and flexibility, plant availability, capacity factors, timing of startup, and the importance of utility economic and financial factors.

1990-04-23

461

Economic analysis of Darrieus vertical axis wind turbine systems for the generation of utility grid electrical power. Volume II. Economic optimization model  

Science.gov (United States)

This report is part of a four-volume study of Darrieus vertical axis wind turbine (VAWT) economics. This volume describes a computer model of VAWT cost and performance factors useful for system design and optimization. The content and limitations of the model are outlined. Output data are presented to demonstrate selection of optima and to indicate sensitivity of energy cost to design parameter variations. Optimized specifications generated by this model for six point designs are summarized. These designs subsequently receive a detailed economic analysis discussed in Volume IV. An appendix is included with a FORTRAN IV listing of the model and a description of the input/output characteristics.

1979-08-01

462

EPRI-USDOE COOPERATIVE AGREEMENT: COFIRING BIOMASS WITH COAL  

Energy Technology Data Exchange (ETDEWEB)

The entire Electric Power Research Institute (EPRI) cofiring program has been in existence of some 9 years. This report presents a summary of the major elements of that program, focusing upon the following questions: (1) In pursuit of increased use of renewable energy in the US economy, why was electricity generation considered the most promising target, and why was cofiring pursued as the most effective near-term technology to use in broadening the use of biomass within the electricity generating arena? (2) What were the unique accomplishments of EPRI before the development of the Cooperative Agreement, which made developing the partnership with EPRI a highly cost-effective approach for USDOE? (3) What were the key accomplishments of the Cooperative Agreement in the development and execution of test and demonstration programs-accomplishments which significantly furthered the process of commercializing cofiring?

2001-09-01

463

Development of ambient sampling chemi/chemical ion source with dielectric barrier discharge  

British Library Electronic Table of Contents (United Kingdom)

The development of a new configuration of chemical ionization (CI)-based ion source is presented. The ambient air containing the gaseous sample is sniffed into an enclosed ionization chamber which is of sub-ambient pressure, and is subsequently mixed with metastable species in front of the ion inlet of the mass spectrometer. Metastable helium atoms (He*) are used in this study as the primary ionizing agents and are generated from a dielectric barrier discharge (DBD) source. The DBD is powered by an AC high-voltage supply and the configuration of the electrodes is in such a way that the generated plasma is confined within the discharge tube and is not extended into the ionization chamber. The construction of the ion source is simple, and volatile compounds released from the bulky sample can...

2010-01-01

464

Corrosion problems and resistance to corrosion of materials for production of steam generators for light water reactor power plants. [Alloys I-600, I-800, I-690  

Energy Technology Data Exchange (ETDEWEB)

Briefly described is knowledge of crevice corrosion, corrosion cracking and denting. In evaluating the corrosion resistance of steam generator materials it is necessary to distinguish corrosion problems caused by the primary coolant side and by the secondary circuit side. At present tubes are manufactured of 7 austenitic alloys of a different chemical composition, and available information shows that views on their corrosion resistance differ. Greatest attention has been devoted to corrosion cracking in the presence of NaOH. Findings related to I-600, I-800, I-690 and AISI 316 are given. Corrodibility by sulfur-containing products is now being studied, namely the intercrystalline corrosion cracking caused by the presence of H/sub 2/S/sub 4/O/sub 6/. Knowledge gained in this respect is summed up.

1984-07-01

465

Corrosion problems and resistance to corrosion of materials for production of steam generators for li.ght water reactor power plants  

International Nuclear Information System (INIS)

Briefly described is knowledge of crevice corrosion, corrosion cracking and denting. In evaluating the corrosion resistance of steam generator materials it is necessary to distinguish corrosion problems caused by the primary coolant eide and by the secondary circuit side. At present tubes are manufactured of 7 austenitic alloys of a different chemical composition, and available information shows that views on their corrosion resistance differ. Greatest attention has been devoted to corrosion cracking in the presence of HaOH. Findings related to I-600, I-800, I-690 and AISI 316 are given. Corrodibility by sulfur-containing products is now being studied, namely the intercrystalline corrosion cracking caused by the presence of H_2S_4O_6. Knowledge gained in this respect is summed up. (J.P.).

466

British Nuclear Fuels PLC: report and accounts 1988-89  

International Nuclear Information System (INIS)

This item covers a meeting held between members of the United Kingdom government's energy committee and representatives of British Nuclear Fuels (BNFL) to discuss their Annual Report and Accounts for the year 1988-89. The committee explored the reasons for escalating predictions of the costs of nuclear power and why decommissioning costs are so difficult to estimate accurately so as to include them in cost per kilowatt hour of generated electricity. The relationship between BNFL and the Ministry of Defence (MoD) was explored, as was the MoD's relationship with the United States Department of Defense. BNFL's financial position should improve when the thermal oxide reprocessing plant at Sellafield becomes operational, and the Chapelcross and Calder Hall reactors may contribute income from electricity generation. (UK).

467

Bidding strategy for pumped-storage plant in pool-based electricity market  

Energy Technology Data Exchange (ETDEWEB)

This paper develops optimal bidding strategies for a pumped-storage plant in a pool-based electricity market. In the competitive regime, when compared to simple hydroelectric generator, profit of the pumped-storage plant is maximized by operating it as a generator when market clearing price is high and as a pump when the price is low. Based on forecasted hourly market clearing price, a multistage looping algorithm to maximize the profit of a pumped-storage plant is developed, considering both the spinning and non-spinning reserve bids and meeting the technical operating constraints of the plant. The proposed model is adaptive for the nonlinear three-dimensional relationship between the power produced, the energy stored, and the head of the associated reservoir. Different operating cycles for a realistic pumped-storage plant are considered and simulation results are reported and compared. (author)

2010-03-15

468

Advanced Flue Gas Desulfurization (AFGD) Demonstration Project. Technical progress report No. 13, January 1, 1993--March 31, 1993  

Science.gov (United States)

The goal of this project is to demonstrate that, by combining state-of-the-art technology, highly efficient plant operation and maintenance capabilities and by-product gypsum sales, significant reductions of SO{sub 2} emissions can be achieved at approximately one-half the life cycle cost of a conventional Flue Gas Desulfurization (FGD) system. Further, this emission reduction is achieved without generating solid waste and while minimizing liquid wastewater effluent. Basically, this project entails the design, construction and operation of a nominal 600 MWe AFGD facility to remove SO{sub 2} from coal-fired power plant flue gas at the Northern Indiana Public Service Company`s Bailly Generating Station.

1994-08-01

469

Low power cross-flow atmospheric pressure Ar + He plasma jet  

International Nuclear Information System (INIS)

A cross-flow atmospheric plasma jet with distilled water or analyte solution nebulization has been investigated. The plasma gas flows perpendicularly to the RF powered electrode (11.21 MHz) and a grounded electrode was added for plasma stabilization. The working parameters of the plasma generator can be controlled in order to maximize either the plasma power (75 W) or the voltage on the RF powered electrode (plasma power, 40 W). The plasma gas, pure argon (0.4 l min-1) or a mixture of argon (0.3-0.4 l min-1) and helium (0-0.2 l min-1), was also used for liquid nebulization. Optical emission of the plasma, collected in the normal viewing mode, was used for plasma diagnostics and for evaluating its excitation capabilities. The influence of helium content in the mixed-gas plasma on the plasma characteristics and on the emission axial profiles of the plasma gas constituents and of the ...

2010-04-01

470

The case of nuclear power: an economical analysis  

Energy Technology Data Exchange (ETDEWEB)

In this paper an analysis will be performed to assess the economical competitiveness of Nuclear Power against other base load technologies. There are several plans to build more nuclear power plants in western countries; these plans are result among other things of the fossil fuel high prices and the concern for the global warming. France started the construction of one EPR at Flamanville in 2007 and at the end of 2008 there were 17 applications before NRC for construction and operation licenses (COL) to build as much as 26 new reactor units in USA, among the designs selected are the US-EPR, APWR, ESBWR, ABWR and AP1000. Currently, there is a lot of uncertainty about what is the overnight cost for a new generation III nuclear power plant and the vendors are not providing too much information. However, it is expected that under the new economy conditions the overnight cost will be between 2500 and 3500 ...

2009-06-15

471

Large turbine, central power generation on offshore production facilities  

Energy Technology Data Exchange (ETDEWEB)

A case study of a hypothetical offshore production fixed leg platform facility is presented. The purpose of the case study is to demonstrate the advantages offered by modern, fuel efficient large gas turbines in central power generation service for offshore production. The case study was presented using the Rolls- Royce RB211 large gas turbine with facility production of approximately 240,000 BPD of oil and 540 MMSCFD of associated gas. The gas was subjected to three stages of separation for removal of hydrocarbon liquids and water. The liquids, natural gas, and crude oil were exported from the production platform to an onshore receiving terminal. Gas compression is the service that requires the greatest amount of power for any given production facility. For this case study, gas compression represented approximately 70 per cent of the power load with the remainder represented by the liquid export pumps ...

2005-07-01

472

Climate Impacts on US Energy Infrastructure: A New High Resolution Model, Policy Implications and Feedbacks  

Science.gov (United States)

We describe the development of a fully coupled climate model configuration where the Community Climate System Model (CCSM) has been coupled with the VERDE (Visualizing Energy Resources Dynamically on the Earth) analysis modules that compute the response of the electric grid to temperature drivers. The VERDE model includes datasets characterizing the 26,500 sub-stations and 6,000 power generation stations fuel mix, efficiency, service areas, and future performance and these have been geo-located on a 1.4 degree latitude by 1.4 degree longitude CCSM grid (T85). The total electric customers have been computed using conversions derived from economic structure and population data. The carbon emissions per customer and the power generation in megawatts electric (MWe) have also been placed on reconciled 1 km, 4 km and the T85 climate model grid. The CCSM temperature for the present and future have been ...

2010-12-01

473

An FEL design for gamma-gamma colliders based on chirped pulse amplification techniques  

International Nuclear Information System (INIS)

A next generation e"+-e"- linear collider in the TeV range can be converted into a #gamma#-#gamma# collider by converting it to e"--e"- operation and then generating #gamma#-rays via Compton backscattering with optical beams. This provides unique access to some areas of fundamental physics as well as highly desirable redundancy to the collisions. The required optical beam (with a wavelength of about 1 micron) must have very high peak power, (about 1 TW) as well as average power (about 10 kW). To achieve a 1 : 1 conversion from an electron to #gamma#-quantum, each micropulse must contain about one Joule and must be about one picosecond long, the micropulse peak power being about one Terawatt. To match the electron beam pulse structure, a macropulse consists of a sequence of about one hundred micropulses separated by about one nanosecond, and the macropulses am repeated at a rate of ...

1995-08-21

474

Unitized regenerative fuel cell systems  

Energy Technology Data Exchange (ETDEWEB)

Energy storage systems with extremely high specific energy (>400 Wh/kg) have been designed that use lightweight pressure vessels to contain the gases generated by reversible (unitized) regenerative fuel cells (URFCs).[1] URFC systems are being designed and developed for a variety of applications, including high altitude long endurance (HALE) solar rechargeable aircraft (SRA), zero emission vehicles (ZEVs), hybrid energy storage/propulsion systems for spacecraft, energy storage for remote (off-grid) power sources, and peak shaving for on-grid applications.[1-10] Energy storage for HALE SRA was the original application for this set of innovations, and a prototype solar powered aircraft (Pathfinder-Plus) recently set another altitude record for all propeller-driven aircraft on August 6, 1998, when it flew to 80,285 feet (24.47 km).[11

1998-09-10

475

The temporal distribution of past and future autobiographical events across the lifespan.  

Science.gov (United States)

Knowledge and awareness of past and future autobiographical events may be mediated by a common system that supports intentional, goal-directed behavior. The purpose of this study was to assess the correspondence of past and future autobiographical thought. In Experiment 1, 300 undergraduates aged 19 years generated and assigned dates to past and f utu re autobiographical events. Thetemporal distribution of past events replicated a power function for retention as has been described in past research. The intention function of future autobiographical events fit the inverse of this same power function, reflecting a temporality of past and future mental time travel centered around the present moment. In Experiment 2, these findings were extended to young, middle-aged, and older groups. These data provide empirical support for the notion that thinking outside of "now" is mediated by a common system, regardless of whether one is ...

2006-12-01

476

The advanced MAPLE reactor concept  

International Nuclear Information System (INIS)

High-flux neutron sources are continuing to be of interest both in Canada and internationally to support materials testing for advanced power reactors, new developments in extracted-neutron-beam applications, and commercial production of selected radioisotopes. The advanced MAPLE reactor concept has been developed to meet these needs. The advanced MAPLE reactor is a new tank-type D_2O reactor that uses rodded low-enrichment uranium fuel in a compact annular core to generate peak thermal-neutron fluxes of 1 x 10"1"9 n#centre dot#s"-"1 in a central irradiation rig with a thermal power output of 50 MW. Capital and incremental development costs are minimized by using MAPLE reactor technology to the greatest extent practicable.

1985-10-14

477

Start safety apparatus for internal combustion engine  

Energy Technology Data Exchange (ETDEWEB)

A start safety apparatus of an engine adapted for a multipurpose power tool is described which consists of: an engine, an exciter coil generating alternate electromotive force in synchronism with rotation of the engine; an ignition coil having primary and secondary windings; a spark plug connected to the secondary winding of the ignition coil; a capacitor connected to the primary winding of the ignition coil the capacitor being charged with a positive half-cycle of the electromotive force; ignition timing control means for controlling discharge of the capacitor; a throttle control latch for setting a throttle valve of the engine in a predetermined throttle angle; a tool driven by the engine; and a centrifugal clutch transferring engine power to the tool when an engine speed exceeds a clutch-in speed.

1986-09-09

478

Safety designs for sludge ducts in brown coal briquetting plants  

Energy Technology Data Exchange (ETDEWEB)

Studies technological safety of installing a water spray pressure vessel between electrostatic dedusters and coal sludge ducts. These sprays are in use elsewhere for steam generator ash removal. Dust ignition and explosion tests were carried out to examine flame and pressure wave propagation through the vessel into ducts. Water jet diameter, amount of water sprayed and coal dust removed were varied. Pressure waves exceeded 250 Pa. Test results show the vessel to be suitable for installation in briquetting plants due to its flame and explosion barrier effect and extermination of smoldering dust fires. The only disadvantage of the vessel is seen as its water and electric power consumption; about 8/sup 3//h of water and 1.5 kW/h of power per vessel serving dedusters of a 2,200 m/sup 2/ rotary brown coal dryer.

1987-06-01

479

Safe design of mud ditches in briquetting factories  

Energy Technology Data Exchange (ETDEWEB)

The authors study technological safety of installing a water spray pressure vessel between electrostatic deduster and coal sludge ducts. These sprays are in use elsewhere for steam generator ash removal. Dust ignition and explosion tests were carried out to examine flame and pressure wave propagation through the vessel into ducts. Water jet diameter, amount of water sprayed and coal dust removed were varied. Pressure waves exceeded 250 Pa. Test results show the vessel to be suitable for installation in briquetting plants due to its flame and explosion barrier effect and extermination of smoldering dust fires. The only disadvantage of the vessel is seen as its water and electric power consumption: about 8 m/sup 3//h of water and 1.5 kW/h of power per vessel serving dedusters of a 2,200 m/sup 2/ rotary brown coal dryer. (MOS).

1987-06-01

480

Research and development on next generation reactor (phase I)  

Energy Technology Data Exchange (ETDEWEB)

The objective of the study is to improve the volume of nuclear power plant which adopts passive safety system concept. The passive safety system reactor is characterized by excellent safety and reliability. But the volume of NSSS (Nuclear Steam Supply System) of the passive safety system reactor is so small that it should be upgraded for commercial operation. For volume upgrade, detailed analyses are performed as follows; core design, hydraulics, design and mechnical structures, and safety analysis. In addition to above analysis, some investigations must be supplied as follows: power density vs. DNB margin decrease, outlet temperature vs. EPRI-URD, additional tests for upgraded reactor, dynamic analysis of mechanical vibration according to expanded reactor vessel and expanded in-core structures, and Merit loss of passive safety system reactor according to design margin decrease. (Author).

1994-10-01

481

Klickitat Cogeneration Project : Final Environmental Assessment.  

Energy Technology Data Exchange (ETDEWEB)

To meet BPA`s contractual obligation to supply electrical power to its customers, BPA proposes to acquire power generated by Klickitat Cogeneration Project. BPA has prepared an environmental assessment evaluating the proposed project. Based on the EA analysis, BPA`s proposed action is not a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act of 1969 for the following reasons: (1)it will not have a significant impact land use, upland vegetation, wetlands, water quality, geology, soils, public health and safety, visual quality, historical and cultural resources, recreation and socioeconomics, and (2) impacts to fisheries, wildlife resources, air quality, and noise will be temporary, minor, or sufficiently offset by mitigation. Therefore, the preparation of an environmental impact statement is not required and BPA is issuing this FONSI ...

1994-09-01

482

Independent power plant using wood waste  

Energy Technology Data Exchange (ETDEWEB)

A 1 MWe power plant using waste wood fuel is to be installed at a US Marine Corps base, which will supply all wood from a landfill site. The core energy conversion technology is a down-draft gasifier supplying approximately 150 Btu/scf gas to both spark ignition and diesel dual-fuel engine-generator sets. Features of the plant design include: (1) grinding wood fuel from a wide range of waste resources, (2) specialized screening for fines removal, (3) complete tar and other waste product control without landfill disposal, and (4) use of process heat for bulk fuel drying, gasifier air pre-heating, and wastewater evaporation.

1995-08-01

483

High efficiency chemical energy conversion system based on a methane catalytic decomposition reaction and two fuel cells. Part II. Exergy analysis  

Energy Technology Data Exchange (ETDEWEB)

A methane catalytic decomposition reactor-direct carbon fuel cell-internal reforming solid oxide fuel cell (MCDR-DCFC-IRSOFC) energy system is highly efficient for converting the chemical energy of methane into electrical energy. A gas turbine cycle is also used to output more power from the thermal energy generated in the IRSOFC. In part I of this work, models of the fuel cells and the system are proposed and validated. In this part, exergy conservation analysis is carried out based on the developed electrochemical and thermodynamic models. The ratio of the exergy destruction of each unit is examined. The results show that the electrical exergy efficiency of 68.24% is achieved with the system. The possibility of further recovery of the waste heat is discussed and the combined power-heat exergy efficiency is over 80%. (author)

2010-10-01

484

High efficiency chemical energy conversion system based on a methane catalytic decomposition reaction and two fuel cells. Part II. Exergy analysis  

British Library Electronic Table of Contents (United Kingdom)

A methane catalytic decomposition reactor-direct carbon fuel cell-internal reforming solid oxide fuel cell (MCDR-DCFC-IRSOFC) energy system is highly efficient for converting the chemical energy of methane into electrical energy. A gas turbine cycle is also used to output more power from the thermal energy generated in the IRSOFC. In part I of this work, models of the fuel cells and the system are proposed and validated. In this part, exergy conservation analysis is carried out based on the developed electrochemical and thermodynamic models. The ratio of the exergy destruction of each unit is examined. The results show that the electrical exergy efficiency of 68.24% is achieved with the system. The possibility of further recovery of the waste heat is discussed and the combined power-heat e...

2010-01-01

485

Enhanced power system stabilizer via integrated tabu-fuzzy knowledge based controller  

Energy Technology Data Exchange (ETDEWEB)

An integrated tabu-fuzzy knowledge based controller applied to enhance the performance of power system stabilizer (PSS) is presented in this paper. The fuzzy knowledge based controller (FKBC) has been developed to perform the function of a PSS and to provide a supplementary signal to the excitation system of the synchronous generator. The method used for storing and representing the fuzzy rules is called the fuzzy associative memory (FAM) matrix. The well-defined FAM determines the performance of the FKBC and hence the tabu search algorithm is proposed and applied to determine the construction and optimization of the FAM. The controller has been tested in the case of single machine infinite bus and multi-machine systems for various types of disturbance. To show the effectiveness of the proposed controller, the comparison with the conventional PSS is presented. (author)

2003-09-01

486

Double plasma mirror for ultrahigh temporal contrast ultra-intense laser pulses  

International Nuclear Information System (INIS)

We present and characterize a very efficient optical device that employs the plasma mirror technique to increase the contrast of high-power laser systems. Contrast improvements higher than 104 with 50% transmission are shown to be routinely achieved on a typical 10 TW laser system when the pulse is reflected on two consecutive plasma mirrors. Used at the end of the laser system, this double plasma mirror preserves the spatial profile of the initial beam, is unaffected by shot-to-shot fluctuations, and is suitable for most high peak power laser systems. We use the generation of high-order harmonics as an effective test for the contrast improvement produced by the double plasma mirrors. (authors)

487

Development of new CAD system for steel structures of nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

IHI has developed a new Three-Dimensional Computer-Aided Design (3D-CAD) system to improve the design efficiency and quality of the steel structure of nuclear power plants. This system covers every design phase from the initial arrangement of structure to the production design sharing the same database. The system incorporates the design rules and professional expertise of designers, and enable easy and efficient design. The system can easily generate the three-dimensional data for structures, model data for stress analyses and composite arrangement data. The system has already been applied to several plants under construction and has achieved excellent results. The outline of the new CAD system is introduced. (author)

1999-09-01

488

Design of a GaAs/Ge solar array for unmanned aerial vehicles  

Energy Technology Data Exchange (ETDEWEB)

Unmanned Aerial Vehicles (UAV) are being proposed for many applications including surveillance, mapping and atmospheric studies. These applications require a lightweight, low speed, medium to long duration airplane. Due to the weight, speed, and altitude constraints imposed on such aircraft, solar array generated electric power is a viable alternative to air-breathing engines. Development of such aircraft is currently being funded under the Environmental Research Aircraft and Sensor Technology (ERAST) program. NASA Lewis Research Center (LeRC) is currently building a Solar Electric Airplane to demonstrate UAV technology. This aircraft utilizes high efficiency Applied Solar Energy Corporation (ASEC) GaAs/Ge space solar cells. The cells have been provided by the Air Force through the ManTech Office. Expected completion of the plane is early 1995, with the airplane currently undergoing flight testing using battery power.

1995-03-01

489

Curecanti-Blue Mesa-Salida 115-kV transmission lines access roads rehabilitation, maintenance, and construction project. Environmental Assessment  

Science.gov (United States)

Western Area Power Administration (Western) is a power marketing agency of the US Department of Energy, with jurisdiction in 15 western states. The Salt Lake City Area (SLCA) of Western performs the agency`s mission in parts of Colorado, New Mexico, Texas, Utah, Arizona, Wyoming, and Nevada. As part of its mission, Western owns, operates, and maintains a system of transmission lines for transmitting bulk electrical energy from points of generation to and between delivery points. Part of that system in southwestern Colorado includes the Blue Mesa-Curecanti and Blue Mesa-Salida 115-kV transmission lines. Western proposes to conduct maintenance and improve its access roads for these two transmission lines. This paper discusses the impacts to the existing environment as well as the environmental consequences resulting from the maintenance and construction that is proposed.

1993-07-01

490

Concerning the statistics of cosmic magnetism  

CERN Document Server

Magnetic fields appear to be a generic feature of the early universe and are a natural source of secondary CMB non-Gaussianity. In recent years the statistical nature of the stresses of a primordial magnetic field has been well studied. In this paper we confirm and extend these studies at one- and two-point level, and present analytical results for a wide range of power-law spectra. We also consider two non-power law cases of interest: a blue spectrum with an extended damping tail on small scales, which could be generated by the non-linear mixing of density and vorticity; and a red spectrum with a damping tail on large scales. We then briefly consider the CMB impacts that result from such fields. While this paper focuses on the one- and two-point moments, the techniques we employ are designed to ease the analysis of the full bispectra induced by primordial magnetic fields.

2010-01-01

491

Comparison between different procedures of reliability analysis for emergency and stand-by power systems  

Energy Technology Data Exchange (ETDEWEB)

A general purpose Emergency Generator Set (EGS) is considered for a methodological study and related reliability behavior is analyzed. In particular in a procedure of reliability and availability analysis of a EGS, dependent failure events need a complex mathematical model as state-space model to be a accurately evaluated. Furthermore these dependent failure events are one of the most important reliability characteristic of EGS. This paper suggests a procedure for reliability calculations in presence of dependent failure based on the evaluation of a equivalent failure rate that can be fitted to a network reduction method by simple mathematical calculations. The simplified models analyzed show a good accuracy for a wide range of variation of main reliability characteristics of EGS and utility. The advantages obtained are very useful on reliability evaluation because the possibility of use of network approach provides a shorter route to calculation and it is ...

1995-12-31

492

Characterisation and use of biomass fly ash in cement-based materials  

British Library Electronic Table of Contents (United Kingdom)

This paper presents results about the characterisation of the biomass fly ashes sourced from a thermal power plant and from a co-generation power plant located in Portugal, and the study of new cement formulations incorporated with the biomass fly ashes. The study includes a comparative analysis of the phase formation, setting and mechanical behaviour of the new cement-fly ash formulations based on these biomass fly ashes. Techniques such as X-ray diffraction (XRD), X-ray fluorescence spectroscopy (XRF), thermal gravimetric and differential thermal analysis (TG/DTA), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and environmental scanning electron spectroscopy (ESEM) were used to determine the structure and composition of the formulations. Fly ash F1 from the t...

2009-01-01

493

Chaos and bifurcation control of SSR in the IEEE second benchmark model  

International Nuclear Information System (INIS)

Linear and nonlinear state feedback controllers are proposed to control the bifurcation of a phenomenon in power system, this phenomenon of electro-mechanical interaction between the series resonant circuits and torsional mechanical frequencies of the turbine-generator sections, which known as subsynchronous resonance (SSR). The first system of the IEEE second benchmark model is considered. The dynamics of the two axes damper windings, automatic voltage regulator and power system stabilizer are included. The linear controller gives better initial disturbance response than that of the nonlinear, but in a small narrow region of compensation factors. The nonlinear controller not only can be easily implemented, but also it stabilizes the operating point for all values of the bifurcation parameter.

2004-07-01

494

Assessment of MCNP-4B code using measurement data of Wolsung nuclear power plant 2  

International Nuclear Information System (INIS)

The benchmark calculations have been performed for MCNP-4B code using the measurement data of Wolsong nuclear power plant 2. In this study, the benchmark calculations have been performed for the criticality, boron worth, reactivity device worth, reactivity coefficient, and flux scan. Cross-section libraries were newly generated from ENDF/B-VI release 3 through NJOY97.114 data processing system and a three-dimensional full core model was developed for MCNP calculation. The simulation results have shown that the criticality is estimated within 4 mkn and the estimated reactivity worth of the control devices are generally consistent with the measurement data. In certain cases, the simulation results have shown large discrepancies against the measurement data, which will be sturdied further in the near future.

2001-05-01

495

An integrated nuclear electro-thermal engine concept for geostationary missions  

International Nuclear Information System (INIS)

A preliminary design for a nuclear electric 'Space Tug' is proposed for use in conjunction with the American Space Shuttle for high energy missions. The vehicle would employ a SNAP 10A/2 or SNAP 8 nuclear reactor derivative for its power supply and slush hydrogen as the working fluid for the electrothermal thrusters. A thermodynamic conversion cycle would be employed for electrical power generation, for which the hydrogen working fluid would perform the duty of the heat sink. The cycle would eliminate the need for heavy waste radiators and improve the overall thermal efficiency. The vehicle promises a considerable payload advantage over a chemical recoverable Tug for geostationary missions. (orig.).

1974-10-14

496

Ageing and life-time management in nuclear power stations - concept and examples; Alterungs- und Lebensdauermanagement in Kernkraftwerken - Konzept und Beispiele  

Energy Technology Data Exchange (ETDEWEB)

Knowledge, assessment and understanding of phenomena caused by ageing, together with systematic utilization and extension of the technical life-time of components and systems, are of critical importance to the safety and economy of electricity generation in nuclear power stations. Economic use can be optimized by integrated ageing and life-time management; it can also be used to improve performance characteristics. (orig.) [Deutsch] Fuer die Sicherheit und Wirtschaftlichkeit der Stromerzeugung in Kernkraftwerken sind die Kenntnis, Bewertung und Beherrschung alterungsbedingter Phaenomene und systematische Ausnutzung bzw. Verlaengerung der technischen Lebensdauer der Komponenten und Systeme von zentraler Bedeutung. Durch ganzheitliches Alterungs- und Lebensdauermanagement, das auch auf die Verbesserung von Leistungsmerkmalen abzielt, kann der wirtschaftliche Nutzen optimiert werden. (orig.)

1999-07-01

497

AZSh protective circuit breaker system  

Energy Technology Data Exchange (ETDEWEB)

The AZSh protective circuit breakers developed by the VNIIVEh Institute and the Prokop'evsk plant for mine automation will replace a number of circuit breaker systems used in underground coal mines in the USSR. The standardized AZSh circuit breaker generation consists of 3 basic types: the AZSh-1, the AZSh-2 and the AZSh-3 systems for power systems with 380 or 660 V voltage. Block scheme of the AZSh system is given. Its specifications are discussed. The AZSh circuit breakers are used for protection of transformer stations from overload and heating as well as for automatic shutdown of energy supply to a power system in emergency situations. Design, basic elements and operation of the AZSh-1, the AZSh-2 and the AZSh-3 protective circuit breakers is evaluated. Commercial production of the AZSh started in 1983.

1984-08-01

498

A study on the transient piping vibration of power plant. Secondary piping system of Wolsung 1 unit  

Energy Technology Data Exchange (ETDEWEB)

In order to maintain a safe operation and availability of generating facilities, qualitative and quantitative assessment of piping vibration was performed vibration sources and damages of piping support was identified on the second piping system of Wolsung nuclear power plant unit 1 .Inspected piping supports and structures in both hot and cold condition .Established evaluation procedures of piping vibration .Performed the static analysis of 2 nd piping system .Established optimal vibration reducing method .The measured vibration level after installing rigid supports and energy absorbing type restraint was reduced about 7 times in velocity unit (author). 24 refs., 95 figs.

1996-08-01

499

A new fuel cell electrocatalyst based on highly porous carbonized polyacrylonitrile foam with very low platinum loading  

Energy Technology Data Exchange (ETDEWEB)

In recent years, interest in the development of a polymer electrolyte fuel cell (PEFC) has considerably increased due to its advantages (e.g., high power density) compared with other fuel cell systems, and its potentials to become the power plant for the next generation, nonpolluting automobile engine. For large scale application of fuel cells, low platinum loading electrode structures are necessary. An electrode based on a highly porous carbonized polyacrylonitrile foam material with very low platinum loading ({approximately} 13 {micro}g/cm{sup 2}) was prepared. The performance of this electrode for oxygen reduction was evaluated and compared with bulk platinum and glassy carbon electrodes.

1996-01-01

500

High power battery test methods for hybrid vehicle applications  

Energy Technology Data Exchange (ETDEWEB)

Commonly used EV battery tests are not very suitable for testing hybrid vehicle batteries, which may be primarily intended to supply vehicle acceleration power. The capacity of hybrid vehicle batteries will be relatively small, they will typically operate over a restricted range of states-of-charge, and they may seldom if ever be fully recharged. Further, hybrid propulsion system designs will commonly impose a higher regeneration content than is typical for electric vehicles. New test methods have been developed for use in characterizing battery performance and life for hybrid vehicle use. The procedures described in this paper were developed from the requirements of the government-industry cooperative Partnership for A New Generation of Vehicles (PNGV) program; however, they are expected to have broad application to the testing of energy storage devices for hybrid vehicles. The most important performance measure for a high ...

1997-11-01