International Nuclear Information System (INIS)
This case study is an application, to a nuclear power plant, of the methodology for quantifying environmental costs and benefits, contained in the regional energy plan, adopted in April, 1983, by the Northwest Power Planning Council, pursuant to Public Law 96-501.The study is based on plant number 2 of the Washington Public Power Supply System (WNP-2), currently nearing completion on the Hanford Nuclear Reservation in eastern Washington State. This report describes and documents efforts to quantify and estimate monetary values for the following seven areas of environmental effects: radiation/health effects, socioeconomic/infrastructure effects, consumptive use of water, psychological/health effects (fear/stress), waste management, nuclear power plant accidents, and decommissioning costs. 103 references.
International Nuclear Information System (INIS)
Oct 1976. 2 p. United States Nuclear Regulatory Commission, Washington,
Guidance on quality assurance requirements during the operations phase of nuclear power plants
International Nuclear Information System (INIS)
26 Oct 1973. 140 p. United States USAEC, Washington, DC
International Nuclear Information System (INIS)
The Washington Department of Fish and Wildlife (WDFW) has been contracted through the Bonneville Power Administration (BPA) and the Grant County Public Utility District (GCPUD) to perform an evaluation of juvenile fall chinook salmon (Oncorhynchus tshawytscha) stranding on the Hanford Reach of the Columbia River. The evaluation, in the fifth year of a multi-year study, has been developed to assess the impacts of water fluctuations from Priest Rapids Dam on rearing juvenile fall chinook salmon, other fishes, and benthic macroinvertebrates of the Hanford Reach. This document provides the results of the 2001 field season.
International Nuclear Information System (INIS)
The Washington Department of Fish and Wildlife (WDFW) has been contracted through the Bonneville Power Administration (BPA) and the Grant County Public Utility District (GCPUD) to perform an evaluation of juvenile fall chinook salmon (Oncorhynchus tshawytscha) stranding on the Hanford Reach. The evaluation, in the fourth year of a multi-year study, has been developed to assess the impacts of water fluctuations from Priest Rapids Dam on rearing juvenile fall chinook salmon, other fishes, and benthic macroinvertebrates of the Hanford Reach. This document provides the results of the 2000 field season.
International Nuclear Information System (INIS)
The Washington Department of Fish and Wildlife (WDFW) has been contracted through the Bonneville Power Administration (BPA) and the Grant County Public Utility District (GCPUD) to perform an evaluation of juvenile fall chinook salmon (Oncorhynchus tshawytscha) stranding on the Hanford Reach. The evaluation, in the third year of a multi-year study, has been developed to assess the impacts of water fluctuations from Priest Rapids Dam on rearing juvenile fall chinook salmon, other fishes, and benthic macroinvertebrates of the Hanford Reach. This document provides the results of the 1999 field season.
International Nuclear Information System (INIS)
The Washington Department of Fish and Wildlife (WDFW) has been contracted through the Bonneville Power Administration (BPA) and the Grant County Public Utility District (GCPUD) to perform an evaluation of juvenile fall chinook salmon (Oncorhynchus tshawytscha) stranding on the Hanford Reach. The evaluation, in the second year of a multi-year study, has been developed to assess the impacts of water fluctuations from Priest Rapids Dam on rearing juvenile fall chinook salmon, other fish species, and benthic macroinvertebrates of the Hanford Reach. This document provides the results of the 1998 field season.
Research Activities in the Spokane, Washington, Field Office...
other chemical applications include use in water softeners, detergents, and food additives. The development of phosphate resources as a leasable commodity provides income to...
2011-08-20
Guidance on quality assurance requirements during the construction phase of nuclear power plants
International Nuclear Information System (INIS)
10 May 1974. 234 p. United States USAEC, Washington, DC WASH--1309.
International Nuclear Information System (INIS)
7 Jun 1973. 110 p. United States USAEC, Washington, DC
Recent developments: Washington focus
International Nuclear Information System (INIS)
November was a quiet month in Washington. Although Congress has recessed until 1991, the Senate filled vacancies in party leadership positions created by November's elections. The House is expected to proceed with its changes in early December. The Nuclear Energy Forum was held in Washington, DC on November 11-14 to discuss the status of the nuclear industry in the USA. The Forum, held in conjunction with the American Nuclear Society's annual meeting, assembled a large number of CEO's from US, European, and Far Eastern utilities and vendors. The meeting concluded with an announcement by Philip Bayne, President of NYPA and chairman of the Nuclear Power Oversight Committee (NPOC), of the results of a year-long NPOC study entitled a open-quotes Strategic Plan for Building New Nuclear Power Plants.close quotes.
International Nuclear Information System (INIS)
... thermal power plants thermal reactors water cooled reactors WATER
This decision document presents the selected remedial action for the former Asarco Tacoma Smelter Facility and adjacent slag peninsula, in Ruston and Tacoma, Washington. This Record of Decision (ROD) describes the final cleanup remedy for soil, slag and surface water and disposal of hazardous soils, demolition debris, and residential soils. This ROD is intended to be an interim action for ground water.
1996-04-01
Combined-cycle cogen plant a successful good neighbor
Energy Technology Data Exchange (ETDEWEB)
This article describes a new natural-gas-fired combined cycle cogeneration plant in Bellingham, Washington. The topics of the article include community impact, siting constraints, natural gas fuel, the flexibility provided by the steam turbine, the cooling tower and pumps, air-quality, noise, and cooling water system constraints, and community relations program.
1993-04-01
FFTF: an outstanding engineering achievement
International Nuclear Information System (INIS)
The Fast Flux Test Facility on the federal reservation at Hanford, Washington, has become a bright star in the universe of nuclear science and engineering technologies. The entire FFTF enterprise is now a success story, and this is particularly significant in these days when good news about nuclear power is scarce. The reactor, its testing capabilities and associated test facilities are described.
Innovative Design of New Geothermal Generating Plants
Energy Technology Data Exchange (ETDEWEB)
This very significant and useful report assessed state-of-the-art geothermal technologies. The findings presented in this report are the result of site visits and interviews with plant owners and operators, representatives of major financial institutions, utilities involved with geothermal power purchases and/or wheeling. Information so obtained was supported by literature research and data supplied by engineering firms who have been involved with designing and/or construction of a majority of the plants visited. The interviews were conducted by representatives of the Bonneville Power Administration, the Washington State Energy Office, and the Oregon Department of Energy during the period 1986-1989. [DJE-2005
1989-07-01
Development and Calibration of Two and Four Wire Water ...
... measurement. Power spectral density measurements are made by the dynamic signal analyzer for each channel. A cross power ...
1992-12-01
Water chemistry and corrosion in water-steam circuits of nuclear power plants
Energy Technology Data Exchange (ETDEWEB)
The water and steam circuits of steam generators in pressurized-water nuclear power plants are described together with the mechanism of denting, and the corrosion of spacer plates that leads to cracks in tubes by constriction. The different chemical specifications applicable to the water of the secondary circuit of the generators in normal operation and on first commissioning are listed. The results obtained and the measurements of chemical values taken in operation on the water in the secondary circuits of steam generators at Fessenheim and Bugey are presented.
1981-05-01
Water chemistry and corrosion in water-steam circuits of nuclear power plants
International Nuclear Information System (INIS)
The water and steam circuits of steam generators in pressurized-water nuclear power plants are described together with the mechanism of denting, and the corrosion of spacer plates that leads to cracks in tubes by constriction. The different chemical specifications applicable to the water of the secondary circuit of the generators in normal operation and on first commissioning are listed. The results obtained and the measurements of chemical values taken in operation on the water in the secondary circuits of steam generators at Fessenheim and Bugey are presented.
Mineralogical study of borehole MW-206 Asarco smelter site, Tacoma, Washington
Energy Technology Data Exchange (ETDEWEB)
The mobility of metals in ground water is an important consideration for evaluating remedial options at the Asarco smelter site. Tacoma, Washington. One factor in assessing metal mobility is the degree of secondary mineralization in a slag-fill aquifer extending into the intertidal zone along the Puget Sound shoreline. Samples of aquifer material were collected for mineralogical analysis from borehole MW-206 at five-foot intervals within the slag fill from 5 to 25 feet below the ground surface, and in the underlying marine sand and gravel at 27 feet. Grab samples of slag fragments with visually apparent secondary minerals were also collected at five intermediate depths between 12 and 19 feet. Samples were analyzed by a variety of techniques including hydride generation/atomic absorption for arsenic concentration, scanning electron microscopy/electron microprobe for mineralogical texture and microanalysis, powder x-ray diffraction for mineral ...
1998-10-01
Washington: a guide to geothermal energy development
Energy Technology Data Exchange (ETDEWEB)
Washington's geothermal potential is discussed. The following topics are covered: exploration, drilling, utilization, legal and institutional setting, and economic factors of direct use projects. (MHR)
1980-06-01
Strategic Communication Enablers for the Regional ...
... Joint Publication (JP) 5-0 (Washington DC: CJCS, 29 September ... and Execution System (JOPES) Volume 1. CJCSM 3122.01A (Washington, DC: 6 ...
2008-04-23
Remaining "Semper Paratus" in the 21st Century
... Joint Publication (JP) 5 (Washington, DC: CJCS, 26 December 2006 ... Policies and Procedures, (Washington, DC: CJCSM, 3122.01A 29 September ...
2008-04-23
Measurement of Lake Roosevelt biota in relation to reservoir operations. Appendices 1991
International Nuclear Information System (INIS)
This report consists of appendices A-F containing the biological data which were collected from Lake Roosevelt, Washington. The data are to be used in the design of a computer model that would predict biological responses of reservoir operations as part of the System Operation Review program. Major components of the model included: Quantification of impacts to phytoplankton, zooplanktons, benthic invertebrates, and fish caused by reservoir drawdowns and low water retention times; quantification of number, distribution, and use of fish food organisms in the reservoir by season; determination of seasonal growth of fish species as related to reservoir operations, prey abundance and utilization; and quantification of entrainment levels of zooplankton and fish as related to reservoir operations and water retention times.
1995-11-05
Training and information technology issue, 2005
The focus of the May-June issue is on training and information technology. Major articles/reports in this issue include: Communicating effectively, by Alain Bucaille, AREVA; Reputation management, by Susan Brisset, Bruce Power; Contol room and HSI modernization guidance, by Joseph Naser, EPRI; How far are we from public acceptance, by Jennifer A. Biedscheid and Murthy Devarakonda, Washington TRU Solutions LLC; Spent fuel management options, by Brent W. Dixon and Steven J. Piet, Idaho National Laboratory; Industry Awards; A secure energy future for America, by George W. Bush, President, United States of America; Vision of the future of nuclear energy, by Anne Lauvergeon, AREVA; and, Plant profile: strategy for transition to digital, TXU Power.
2005-05-15
Five years operating experience at the Fast Flux Test Facility
Energy Technology Data Exchange (ETDEWEB)
The Fast Flux Test Facility (FFTF) is a 400 Mw(t), loop-type, sodium-cooled, fast neutron reactor. It is operated by the Westinghouse Hanford Company for the United States Department of Energy at Richland, Washington. The FFTF is a multipurpose test reactor used to irradiate fuels and materials for programs such as Liquid Metal Reactor (LMR) research, fusion research, space power systems, isotope production and international research. FFTF is also used for testing concepts to be used in Advanced Reactors which will be designed to maximize passive safety features and not require complex shutdown systems to assure safe shutdown and heat removal. The FFTF also provides experience in the operation and maintenance of a reactor having prototypic components and systems typical of large LMR (LMFBR) power plants. The 5 year operational performance of the FFTF reactor is discussed in this report. 6 refs., 10 figs., 2 tabs.
1987-04-01
Five years operating experience at the Fast Flux Test Facility
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a 400 Mw(t), loop-type, sodium-cooled, fast neutron reactor. It is operated by the Westinghouse Hanford Company for the United States Department of Energy at Richland, Washington. The FFTF is a multipurpose test reactor used to irradiate fuels and materials for programs such as Liquid Metal Reactor (LMR) research, fusion research, space power systems, isotope production and international research. FFTF is also used for testing concepts to be used in Advanced Reactors which will be designed to maximize passive safety features and not require complex shutdown systems to assure safe shutdown and heat removal. The FFTF also provides experience in the operation and maintenance of a reactor having prototypic components and systems typical of large LMR (LMFBR) power plants. The 5 year operational performance of the FFTF reactor is discussed in this report. 6 refs., 10 figs., 2 tabs.
1987-09-13
British Library Electronic Table of Contents (United Kingdom)
The article examines the limits and challenges small powers face when they adjust to systemic changes. Specifically, this article discusses the Philippines' conduct of a diplomatic strategy of equi balancing between the USA and China. In this strategy, the Philippines enhances and deepens its security relations with its strategic ally, the USA and at the same time, obtains economic assistance and politico diplomatic concessions from East Asia's emergent power, China. The Philippines' diplomatic gambit, however, is restrained by its formal alliance with the USA and its chronic territorial dispute with China over the Spratly Islands. At present, several developments are undermining Manila's efforts in playing this balancing game with Washington and Beijing. These are: the Philippines' passiv...
2010-01-01
Microprocessor-controlled anodic stripping voltammeter for trace metal analysis in tap water
Energy Technology Data Exchange (ETDEWEB)
The construction and use of a portable, microprocessor controlled anodic stripping voltameter for on-site simultaneous metal analysis of copper, lead and cadmium in tap water is discussed. The instrumental system is comprised of a programmable controller which permits keying in analytical parameters such as sparge time and plating time: a rotating cell for efficient oxygen removal and amalgam formation; and, data handling via a minicomputer or analog pen recorder. Plating and stripping potentials are controlled by a digital potentiostat; stripping is done using a staircase waveform with measurement of the current after a one msec delay. In this way charging current effects are minimized. Results of tap water analysis showed 3 +- 1 ..mu..g/L lead, 22 +- 0.3 ..mu..g/L copper, and less than 0.2 ..mu..g/L cadmium for a Berkeley, California tap water, and 1-1000 ..mu..g/L Cu, 1 -2 ..mu..g/L Pb for ten samples of Seattle, ...
1984-06-01
British Library Electronic Table of Contents (United Kingdom)
Ways of improving the water chemistry used in the turbine generator stator?s cooling systems at Russian nuclear power plants are considered. Data obtained from operational chemical monitoring of indicators characterizing the quality of cooling water in the turbine generator stator cooling systems of operating power units at nuclear power plants are presented.
2011-01-01
Conception and design of steam power plants
International Nuclear Information System (INIS)
The manual presents the fundamentals of thermodynamics and fluid mechanics, the main components of steam power plants, and the power generation process. The following concepts and subjects are discussed at length: steam generator; steam turbines; turbogenerators; condensers; cooling technology; water/steam cycle and water treatment; design data of fossil-fuelled power plants; design and optimisation of nuclear power plant thermodynamics; pipelines and fittings; control systems in steam power plants; connection to the electricity grid and self-supply of thermal power plants; power plant transformer concepts and definitions. (HAG).
International Nuclear Information System (INIS)
The research committee of the Atomic Energy Society of Japan on water chemistry standard aims at establishing the private standard of water chemistry of nuclear power plants. The committee gathers up 'BWR water chemistry management manual', 'PWR primary system water chemistry management manual' and 'PWR water chemical analysis standard method', and furthermore aims at the standardization of those in future. Looking back on the committee's activities for the past four years, latest results of research of water chemistry mainly contributing to safe and reliable nuclear power plants were described with the future perspective of water chemistry and a demanded break-through. (T.T.)
2007-05-01
International Nuclear Information System (INIS)
This guide describes an acceptable method of complying with the Commission's regulations with regard to the quality assurance requirements for the packaging, shipping, receiving, storage, and handling of items for water-cooled nuclear power plants.
Combining innovative technology demonstrations with dense nonaqueous phase liquids cleanup
Energy Technology Data Exchange (ETDEWEB)
Radioactively contaminated acidic aqueous wastes and organic liquids were discharged to the soil column at three disposal sites within the 200 West Area of the Hanford Site, Washington. As a result, a portion of the underlying groundwater is contaminated with carbon tetrachloride several orders of magnitude above the maximum contaminant level accepted for a drinking water supply. Treatability testing and cleanup actions have been initiated to remove the contamination from both the unsaturated soils to minimize further groundwater contamination and the groundwater itself. To expedite cleanup, innovative technologies for (1) drilling, (2) site characterization, (3) monitoring, (4) well field development, and (5) contaminant treatment are being demonstrated and subsequently used where possible to improve the rates and cost savings associated with the removal of carbon tetrachloride from the soils and groundwater.
1993-05-01
Energy Technology Data Exchange (ETDEWEB)
This document represents the FY2002 BPA contract Statement of Work for the Yakama Nation (YN) portion of the project entitled 'Assessment of current and potential salmonid production in Rattlesnake Creek associated with restoration efforts'. The purpose of the project is to complete detailed surveys of water quality, fish populations, habitat conditions and riparian health in the Rattlesnake Creek sub-basin of the White Salmon River in south central Washington. Results of the surveys will be used to establish Rattlesnake Creek sub-basin baseline environmental factors prior to anticipated removal of Condit Dam in 2006 and enable cost-effective formulation of future watershed restoration strategies.
2003-05-01
Transportation cost of nuclear off-peak power for hydrogen production based on water electrolysis
International Nuclear Information System (INIS)
The paper describes transportation cost of the nuclear off-peak power for a hydrogen production based on water electrolysis in Japan. The power could be obtainable by substituting hydropower and/or fossil fueled power supplying peak and middle demands with nuclear power. The transportation cost of the off-peak power was evaluated to be 1.42 yen/kWh when an electrolyser receives the off-peak power from a 6kV distribution wire. Marked reduction of the cost was caused by the increase of the capacity factor. (author)
Energy Technology Data Exchange (ETDEWEB)
Potential maximum radiation dose rates over a 1,000-year time horizon were calculated for exposure to the decontaminated concrete removed from the 183-H Solar Evaporation Basins at the Hanford Site, Richland, Washington. The RESRAD computer code, Version 5.62, which implements the methodology described in the US Department of Energy`s manual for developing residual radioactive material guidelines, was used in this evaluation. Currently, the concrete is not being used. Four potential exposure scenarios were developed for the land area where the decontaminated concrete will be stored. In Scenario A industrial use of the land is assumed; in Scenario B recreational use of the land is assumed; in Scenario C residential use of the land is assumed; and in Scenario D (a plausible but unlikely land-use scenario), the presence of a subsistence farmer in the immediate vicinity of the land is assumed. For Scenarios A and B, water used for drinking is ...
1997-01-01
Energy Technology Data Exchange (ETDEWEB)
Bonneville Power Administration (BPA) is proposing to fund the Tucannon River Spring Chinook Captive Broodstock Program, a small-scale production initiative designed to increase numbers of a weak but potentially recoverable population of spring chinook salmon in the Tucannon River in the State of Washington. BPA has prepared an Environmental Assessment (EA) (DOE/EA-l326) evaluating the proposed project. Based on the analysis in the EA, BPA has determined that the proposed action is not a major Federal action significantly affecting the quality of the human environment, within the meaning of the National Environmental Policy Act (NEPA) of 1969. Therefore, the preparation of an Environmental Impact Statement (EIS) is not required, and BPA is issuing this Finding of No Significant Impact (FONSI).
2000-05-24
Liquid metal reactor cover gas purification and analysis in the USA
International Nuclear Information System (INIS)
Two sodium cooled reactors are currently being operated in the United States of America for the US Department of Energy. These are Experimental Breeder Reactor 11, EBR-11, and the Fast Flux Test Facility, FFTF. EBR-11 is located near Idaho Falls, Idaho, and the FFTF is near Richland, Washington. These reactors are currently engaged in a wide range of testing including fuels and materials tests, and plant system performance and safety development. The US DOE program also includes designs of a next generation sodium cooled power reactor. The FFTF and EBR-11 communities are providing input to these designs. This paper discusses the efforts to develop and operate cover gas systems for the sodium cooled nuclear reactor program in the USA.
1986-09-24
FFTF operating experience, 1982-1984
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a 400 Mwt sodium-cooled fast reactor operating at the Hanford Engineering Development Laboratory, Richland, Washington, to conduct fuels and materials testing in support of the US Liquid Metal Fast Breeder Reactor (LMFBR) program. Startup and initial power testing included a comprehensive series of nonnuclear and nuclear tests to verify the thermal, hydraulic, and neutronic characteristics of the plant. A specially designed series of natural circulation tests were then performed to demonstrate the inherent safety features of the plant. Early in 1982, the FFTF began its first 100-day irradiation cycle. Since that time the plant has operated very well, achieving a cycle capacity factor of 94% in the most recent irradiation cycle. Seventy-five specific test assemblies and 25,000 individual fuel pins have been irradiated, some in excess of 80 MWd/Kg.
1984-04-09
Corrosion behavior of iron and nickel base alloys in high temperature and pressure water
International Nuclear Information System (INIS)
In equipment industries, the equipments handling industrial water and pure water are numerous. In power generation including nuclear power generation, water serves as a working medium. Review is made on the experiences in the corrosion of iron and nickel base alloys in high temperature, high pressure water and the results of researches derived from them. Under high temperature and high pressure, carbon steel, low alloy steel, stainless steel and high nickel alloy cause corrosion even in pure water. But in the case of serious corrosion, chlorine, oxygen, alkali and others in water take part. The following matters are described: corrosion by steam; stress corrosion cracking in pure water; corrosion by impurities in high temperature, high pressure pure water, i.e. chlorine ions, ...
Energy Technology Data Exchange (ETDEWEB)
A study of mine-waste contamination effects on Methow River habitat on the eastern slopes of the north Cascade Mountains in Washington state, U.S.A., revealed impacts at ecosystem, community, population, individual, tissue, and cellular levels. Ore deposits in the area were mined for gold, silver, copper and zinc until the early 1950's, but the mines are now inactive. An above-and-below-mine approach was used to compare potentially impacted to control sites. The concentrations of eleven trace elements (i.e., Al, As, B, Ba, Cd, Cr, Cu, Mn, Pb, Se, and Zn) in Methow River sediments downstream from the abandoned mine sites were higher than background levels. Exposed trout and caddisfly larvae in the Methow River showed reduced growth compared to controls. Samples of liver from juvenile trout and small intestine from exposed caddisfly larvae were examined for evidence of metal accumulation, cytopathological change, and chemical toxicity. Morphological changes ...
2003-05-15
Secretary of State Clinton Photos: July
Washington, DC -07/24/09 Photo: Secretary Clinton and Iraqi Prime Minister al-Maliki at HCC Bilateral; Washington, DC -07/24/09 Photo: Secretary Clinton at Joint Press...
2011-09-18
International Nuclear Information System (INIS)
In this paper, we calculated the radioactive concentration distribution of radioactive waste water, the temperature distribution of drained cooling water and the effect of implement from the Daya Bay Nuclear Power Plant on nearby waters range, discussed and analysed some problems of computational results and computation with Alternating Direction Implicit Method (ADI). The contents of the article included: the establishment of two-dimension tidal current equation, radioactive waste water pollutant dispersion equation and cooling water heat convection diffusion equation, the numerical difference calculation model of tidal current field, concentration field as well as temperature field, effect impingement with ADI method, numerical calculation results. The result of research showed that: when the Daya Bay Nuclear Power Plant is on normal ...
Contingency interim measure for the public water supply at Barnes, Kansas.
Energy Technology Data Exchange (ETDEWEB)
This document presents a conceptual design for a contingency interim measure (IM) for treatment of the public water supply system at Barnes, Kansas, should this become necessary. The aquifer that serves the public water supply system at Barnes has been affected by trace to low concentrations of carbon tetrachloride and its degradation product, chloroform. Investigations conducted on behalf of the CCC/USDA by Argonne National Laboratory (Argonne 2008a) have demonstrated that groundwater at the Barnes site is contaminated with carbon tetrachloride at concentrations exceeding the Kansas Tier 2 risk-based screening level (RBSL) and the EPA maximum contaminant level (MCL) of 5.0 {micro}g/L for this compound. The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) formerly operated a grain storage facility in Barnes, approximately 800 ft east-southeast of the public water supply wells. Carbon ...
2009-07-09
Characterization and remediation of highly radioactive contaminated soil at Hanford
Energy Technology Data Exchange (ETDEWEB)
The Hanford Site, Richland, Washington, contains over 1,500 identified waste sites and numerous groundwater plumes that will be characterized and remediated over the next 30 years. As a result of the Hanford Federal Facility Agreement and Consent Order, the US Department of Energy (DOE) has initiated a remedial investigation/feasibility study (RI/FS) at the 200-BP-1 operable unit. The 200-BP-1 RI/FS is the first Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) investigation on the Hanford Site that involves highly radioactive and chemically contaminated soils. The initial phase of site characterization was designed to assess the nature and extent of contamination associated with the source waste sites within the 200-BP-1 operable unit. Characterization activities consisted of drilling and sampling, chemical and physical analysis of samples, and development of a conceptual vadose zone model. These data were then used. to develop ...
1993-09-01
Steam generator tube failures: experience with water-cooled nuclear power reactors during 1976
International Nuclear Information System (INIS)
A survey was conducted of experience with steam generator tubes at nuclear power stations during 1976. Failures were reported at 25 out of 68 water-cooled reactors. The causes of these failures and the repair and inspection procedures designed to cope with them are summarized. Examination of the data indicates that corrosion was the major cause of steam generator tube failures. Improvements are needed in steam generator design, condenser integrity and secondary water chemistry control. (author).
1994-10-18
International water power and dam construction yearbook 1996
Energy Technology Data Exchange (ETDEWEB)
This document draws together data on hydroelectric power generation and dam construction for 1996. Machinery such as turbines and hydroelectric generators are listed together with their manufacturers. Contact addresses for international organizations concerned with water power are listed. Listings are also given for hydro resources worldwide, and the global distribution of pumped-storage plants, dams and hydroelectric plants. Company data is also listed providing a buyer`s guide for 1996. (UK)
1996-12-31
Hydroelectric and pumped storage plants
Energy Technology Data Exchange (ETDEWEB)
All power plant engineers face the problem of peak power demands. Pumped storage plants are used to generate peak load power by pumping up water utilizing off-peak energy of hydrothermal and thermonuclear plants. This is the first accessible text/reference to cover hydroelectric power generation with emphasis on engineering to meet peak power demands by means of pumped storge plants, tidal power plants, and low head power generation. Text covers hydrology, mechanical and electrical equipment, accessories such as penstocks and valves, and civil engineering considerations. Contains descriptions of several existing plants. Includes 200 diagrams and 50 photographs.
1989-01-01
Hydroelectric and pumped storage plants
Energy Technology Data Exchange (ETDEWEB)
All power plant engineers face the problem of peak power demands. Pumped storage plants are used to generate peak load power by pumping up water utilizing off-peak energy of hydrothermal and thermonuclear plants. This is a reference to cover hydroelectric power generation with emphasis on engineering to meet peak power demands by means of pumped storage plants, tidal power plants, and low head power generation. Text covers hydrology, mechanical and electrical equipment, accessories such as penstocks and valves, and civil engineering considerations. Contains descriptions of several existing plants. Includes 200 diagrams and 50 photographs.
1988-01-01
Natural vegetation at the proposed Reference Repository Location in southeastern Washington
International Nuclear Information System (INIS)
The dominant shrubs were sagebrush and spiny hopsage; the herbs were dominated by cheatgrass and Sandberg bluegrass. Spiny hopsage appeared to be vulnerable to burning and also to damage by off-road vehicular traffic. It appears to have little or no ability to reproduce through seedlings; once the existing plants are killed they are not likely to be replaced, even if seed-producing plants are nearby. The only pure stand of spiny hopsage known to exist on the Hanford Site is on and near study plot 2H. Sagebrush, like spiny hopsage, is killed by burning and by heavy vehicles. Sagebrush is capable of reproducing via seeds, indicating that it is an inherently aggressive species with a capacity to reestablish itself if parent plants are in the vicinity to act as seed sources. Alien, annual plants, especially cheatgrass, were a major contributor to the herbaceous canopy cover in plots 3S, 4S, and 5S. However, native perennial grasses, especially Sandberg bluegrass, were a major contributor ...
Redox potential measurement in the power station
Energy Technology Data Exchange (ETDEWEB)
By its very nature redox potential measurement is suitable for determining the concentration ratio of a stable redox pair through its interaction with a chemically inert electrode surface but not the absolute concentration of a material. The measured redox potentials agree only rarely with those which are easily calculable theoretically. No individual defined stable redox pair is available in power station water. It is therefore not simply possible to measure definable mixed potentials more precisely. For these reasons redox potential measurement in the power station, as also with other types of water, can no longer be regarded as an indicator, by which it can be established whether oxidizing or reducing materials predominate in the water.
1983-01-01
Redox potential measurement in the power station
International Nuclear Information System (INIS)
By its very nature redox potential measurement is suitable for determining the concentration ratio of a stable redox pair through its interaction with a chemically inert electrode surface but not the absolute concentration of a material. The measured redox potentials agree only rarely with those which are easily calculable theoretically. No individual defined stable redox pair is available in power station water. It is therefore not simply possible to measure definable mixed potentials more precisely. For these reasons redox potential measurement in the power station, as also with other types of water, can no longer be regarded as an indicator, by which it can be established whether oxidizing or reducing materials predominate in the water. (orig.).
Feedwater control device of the steam generator in an atomic power station
International Nuclear Information System (INIS)
Purpose: In a case of automatically controlling the water level at the time of generating a lower power, to impact the followability of the control necessary for the power variation of the steam generator thereby to obtain good controllability. Constitution: A signal of deviation of water level of a steam generator and its set value and a signal of a difference between the temperature of the primary coolant in the high temperature side pipeline and that of the primary coolant in the low temperature side pipeline are used to automatically or manually control the flow quantity of water fed to the steam generator. (Yoshihara, H.).
International Nuclear Information System (INIS)
The major feed-water line break accident is re-analyzed, which is based on Guangdong Daya Bay nuclear power station final safety analysis report, to justify the impacts of the decreasing of auxiliary feed-water flow rate on the safety margin in Daya Bay. The results showed that the accident analysis can meet the demands of acceptance criteria with the auxiliary feed-water flowrate decreasing from 45 m"3/h to 41.8 m"3/h, and enough safety margin is still retained
2002-06-01
Quality assurance requirements for protective coatings applied to water-cooled nuclear power plants
International Nuclear Information System (INIS)
Jun 1973. 2 p. United States USAEC Directorate of Regulatory Standards,
International Nuclear Information System (INIS)
... Dozaki, Koji Takiguchi, Hideki Japan Atomic Power Company, Tokyo (Japan)
2008-05-01
The Polish Nuclear Society on the energy situation in Poland
Energy Technology Data Exchange (ETDEWEB)
Discusses the resolution of the 2. Congress of the Polish Nuclear Society on the energy situation in Poland and recommendations for energy policy. Recommendations for use of nuclear power plants in Poland are made considering environmental pollution from coal combustion (air pollution by sulfur dioxide, nitrogen oxides and carbon dioxide as well as water pollution by salt from mine water discharged to rivers), development of the Polish economy, forecast increase in energy consumption and the role of nuclear energy in other European countries. Research on nuclear power plants, safety and environmental aspects as well as comparative efficiency of coal-fired power plants and nuclear power plants is evaluated.
1993-10-01
The green power option to gain market advantage
Energy Technology Data Exchange (ETDEWEB)
Deregulation of the electric power industry in Alberta holds the prospect of providing greater choice for customers. One such option will be `green power` which is provided by renewable energy technologies. The energy produced would be without environmental impacts such as air emissions, water pollution, flooding, thermal emissions or waste by-products. Wind power, small scale hydro power, photovoltaics and biomass technologies have been termed as `green power`. The choices that customers make will not be focused on price alone. Market forces are emerging to demand reduction in emissions which will result in a market for `green energy` products and facilitate achieving goals for a sustainable future.
1997-03-01
Energy Technology Data Exchange (ETDEWEB)
Cooling waters from eleven geographically disparate power plants were tested for the presence of Naegleria fowleri and Legionella pneumophila (LDB). Control source waters for each plant were also tested for these pathogens. Water from two of the eleven plants contained pathogenic Naegleria, and infectious Legionella were found in seven of the test sites. Pathogenic Naegleria were not found in control waters, but infectious Legionella were found in five of the eleven control source water sites. Concentrations of nitrite, sulfate, and total organic carbon correlated with the concentrations of LDB. A new species of Legionella was isolated from one of the test sites. In laboratory tests, both Acanthamoeba and Naegleria were capable of supporting the growth of Legionella pneumophila.
1982-10-01
Energy saving self-powered industrial dehumidifier
Energy Technology Data Exchange (ETDEWEB)
An energy saving self-powered industrial dehumidifier for use in a building having a tap water conduit leading from a source of supply to utilization points is described comprising: a dehumidifying apparatus positioned in a stream of air to be dehumidified in the building. The dehumidifying apparatus comprising conduit means for diverting at least a portion of a relatively continuously moving stream of tap water from the tap water conduit through a heat exchanger positioned in a stream of air and returning the diverted portion to the tap water stream upstream of the utilization points. Water vapor in the stream of air will condense onto the heat exchanger when the tap water has a temperature below a dew point temperature of the air stream, thereby dehumidifying the air stream.
1988-07-26
Trace elements were extracted from a coal-fired power plant electrostatic precipitator ash with nitric acid, hydrochloric acid, citric acid, redistilled water, and ammonium hydroxide as extractants. Effluent waters at this plant were sampled to assess the elevation of trace element concentrations compared with intake waters. The results showed a positive correlation between those elements most extractable by water (B, F, Mo, and Se) or acid (As, B, Cd, F, Mo, and Se) and those elements most elevated in effluent waters (As, B, F, Mo, and Se).
1977-10-01
Performance of single cylinder, direct injection diesel engine using water fuel emulsions
Energy Technology Data Exchange (ETDEWEB)
A single cylinder diesel engine study of water-in-diesel emulsions was conducted to investigate the effect of water emulsification on the engine performance and gases exhaust temperature. Emulsified Diesel fuels of 0, 5, 10, 15 and 20 water/diesel ratios by volume were used in a single cylinder, direct injection diesel engine, operating at 1200-3300 rpm. The results indicate that the addition of water in the form of emulsion improves combustion efficiency. The engine torque, power and brake thermal efficiency increase as the water percentage in the emulsion increases. The average increase in the brake thermal efficiency for 20% water emulsion is approximately 3.5% over the use of diesel for the engine speed range studied. The proper brake specific fuel consumption and gases exhaust temperature decrease as the percentage of ...
2004-03-01
Hydroelectric power in Switzerland: large growth potential by increasing the installed power
International Nuclear Information System (INIS)
Due to its important hydroelectric power generation facilities (about 525 plants with a total power of 13,314 MW producing about 35.3 TWh annually) Switzerland plays an important role in the interconnected European power system. Large artificial storage lakes in the Swiss Alps can generate peak power during hours of highest demand: 9700 MW are available from accumulated energy and the total power of pumped-storage facilities amounts to 1700 MW. The latter allow refilling the reservoirs at periods of low power demand and generating power at periods of peak demand. In the case of favorable conditions, the yearly average power production could be increased by 6% and the production during the winter period (October to March) by 20% by the year 2020. However, looking forward to the year 2050, the annual production is expected ...
Prevention of lung cancer by remediation of residential exposure to radon daughters
Energy Technology Data Exchange (ETDEWEB)
The United States Bonneville Power Administration (BPA), as part of an energy conservation programme in the states of Washington, Oregon, Idaho, Wyoming, and Montana, has collected over 36,000 residential radon concentration measurements. Data were collected between 1983 and 1989 with ambient {alpha} etched track dosemeters. Based on the linear risk coefficient from the BEIR IV report for lifetime lung cancer in smokers and non-smokers, numbers of lung cancer cases attributable to radon exposure were predicted. Numbers of baseline lung cancer cases and numbers of these that were preventable by remediation were also estimated. Remediation to 10 pCi.1{sup -1}, to 4 pCi.1{sup -1}, and to outdoor levels were considered. With vital statistics data, results were extrapolated to populations in the states represented by the BPA data. Costs of remediation were estimated. Results were evaluated in terms of cost per cancer saved and per cent reduction in ...
1991-01-01
The application of MOX fuel in light water nuclear power plant
International Nuclear Information System (INIS)
MOX fuel has been one of the mature nuclear fuels which can be used in light water nuclear power plant now. The development status in this domain in foreign countries, the major influence of MOX fuel on reactor performance and the countermeasures are introduced in this paper. The application of MOX fuel in China's PWR is discussed in the end. (authors)
2008-12-01
Energy Technology Data Exchange (ETDEWEB)
This standard addresses the design bases for light water reactor, nuclear power plant structures and components essential for the protection of public health and safety from the potential adverse effects of pipe whip, jet impingement, pressurization of compartments outside containment, environmental conditions and flooding associated with a postulated pipe rupture. The design bases for missile protection and the design bases for containment pressurization are not within this standard.
1981-01-01
Cause analysis of cracks in circulating water culvert of Daya Bay Nuclear Power Station
International Nuclear Information System (INIS)
In view of the widespread cracks discovered in the reinforced-concrete circulating water culvert of Daya Bay Nuclear Power Station, cause analysis for the cracks is made in terms of construction and design. It is concluded that the cracks mainly resulted from shrinkage and temperature. Corresponding countermeasures are put forward thereafter for reference of similar projects
2000-06-01
Energy Technology Data Exchange (ETDEWEB)
This standard addresses the design bases for light water reactor, nuclear power plant structures and components essential for the protection of public health and safety from the potential adverse effects of pipe whip, jet impingement, pressurization of compartments outside containment, environmental conditions and flooding associated with a postulated pipe rupture. The design bases for missile protection and the design bases for containment pressurization are not within this standard.
1980-12-31
Some sensitivities during a LWR severe core-damage sequence
International Nuclear Information System (INIS)
Stable boiloff of core water during a severe LWR accident, that is, boiloff driven only by the decay power generated below the water level, is tractable analytically and is relatively insensitive to axial power distribution. As might be expected, calculated accident event times are sensitive to the fidelity of the decay power model. During later stages of boiloff, heat transfer or transport of energy from above the water level to the residual water can result in an unstable condition during which the boiloff rate increases greatly. The unstable boiloff phenomenon illustrates the highly nonlinear influence of core heat transfer during meltdown and emphasizes the great accuracy requirements which attend the modeling of the accident during periods of enhanced heat transfer when significant zirconium oxidation is possible.
1981-12-04
Device for controlling feedwater at low power of nuclear power plants
International Nuclear Information System (INIS)
Purpose: To provide a feedwater control device capable of minimizing the adverse response of steam drum level at low power. Consitution: In order to perform feedwater control at low power by the substantial control of three factors, that is, main steam flow rate, feedwater flow rate and steam drum level, the main steam flow rate is determined from the reactor output and feedwater rate is determined from the changes in the feedwater temperature due to the mixing of waters in the reactor clean up system and feedwater. If a difference is resulted between these flow rates, a starting feedwater regulator is controlled instantly to eliminate the difference. The water level in the steam drum is used for amending the difference from the final set value of the drum water level, by which the adverse response of the steam drum level can be minimized. (Seki, T.).
Safety designs for sludge ducts in brown coal briquetting plants
Energy Technology Data Exchange (ETDEWEB)
Studies technological safety of installing a water spray pressure vessel between electrostatic dedusters and coal sludge ducts. These sprays are in use elsewhere for steam generator ash removal. Dust ignition and explosion tests were carried out to examine flame and pressure wave propagation through the vessel into ducts. Water jet diameter, amount of water sprayed and coal dust removed were varied. Pressure waves exceeded 250 Pa. Test results show the vessel to be suitable for installation in briquetting plants due to its flame and explosion barrier effect and extermination of smoldering dust fires. The only disadvantage of the vessel is seen as its water and electric power consumption; about 8/sup 3//h of water and 1.5 kW/h of power per vessel serving dedusters of a 2,200 m/sup 2/ rotary brown coal dryer.
1987-06-01
Safe design of mud ditches in briquetting factories
Energy Technology Data Exchange (ETDEWEB)
The authors study technological safety of installing a water spray pressure vessel between electrostatic deduster and coal sludge ducts. These sprays are in use elsewhere for steam generator ash removal. Dust ignition and explosion tests were carried out to examine flame and pressure wave propagation through the vessel into ducts. Water jet diameter, amount of water sprayed and coal dust removed were varied. Pressure waves exceeded 250 Pa. Test results show the vessel to be suitable for installation in briquetting plants due to its flame and explosion barrier effect and extermination of smoldering dust fires. The only disadvantage of the vessel is seen as its water and electric power consumption: about 8 m/sup 3//h of water and 1.5 kW/h of power per vessel serving dedusters of a 2,200 m/sup 2/ rotary brown coal dryer. (MOS).
1987-06-01
Heavy water leak due to fretting of DN tube
International Nuclear Information System (INIS)
Wolsung nuclear power plant has experienced four occasions of reactor shutdown owing to heavy water leaks since its commercial operation. Among these heavy water leaks, only one case was acute and brought about reactor shutdown but the other cases listed below were chronic and repaired after manual reactor shutdown. (author). 4 tabs., 10 figs.
1989-06-04
Corrosion of Cu-W condensates in tap water
International Nuclear Information System (INIS)
Corrosion resistance of Cu-W system condensates in tap water was studies. It is shown that with an increase in W concentration in the condensates of the Cu-W system their corrosion in tap water enhances. In the material designated for power supply facilities the optimal tungsten content is up to 6%. Owing to formation of oxide film on the surface of the samples corrosion is stabilitized 40 h after the test start.
Evolution of reactivity control mechanisms for nuclear research and power reactors in India
International Nuclear Information System (INIS)
Division of Remote Handling and Robotics (DRHR) at Bhabha Atomic Research Centre (BARC) has been working on design and development of Reactivity Control Mechanisms for Nuclear Research Reactors (Dhruva, KAMINI and recently Critical Facility of Advanced Heavy Water Reactor (AHWR)) as well as Power Reactors in India (Pressurized Heavy Water Reactors of 220 MWe at Narora and recently India's first 540 MWe PHWR Unit -1 and 2 at Tarapur). This paper gives a brief account of evolution of reactivity control mechanisms for nuclear research and power reactors in India. (author)
2009-10-01
WASHINGTON UNIVERSITY - NASA Technical Reports Server
Although private schools are available, universal basic education is generally regarded as involving certain benefits which are, external to ...
Untitled - NASA Technical Report Server (NTRS)
Joint Committee on Atomic Energy. Comgress of the United States. Washington, D. C.. 1 - Chief, Life Sciences Division. A m y Research Office ...
The Theater JFACC Construct: Creating Disunity of Command ...
... WHS- Washington Headquarters Service ... paper will advocate assignment of a Commander, Air Force Forces for all Joint Task Forces conducting ...
2009-04-01
The Future of Amphibious Operations: Shaping the ...
... WHS- Washington Headquarters Service. ... US Military (ie, Army, Navy, Air Force) service publications ... Strike Group to Fight in the Joint Task Force. ...
2010-02-01
State Cancer Profiles Home Page
Washington West Virginia Wisconsin Wyoming Cancer --- Choose a Cancer Site --- All Cancer Sites Bladder Brain & ONS Breast (Female) Breast (Female in situ) Cervix Childhood...
2011-10-15
Reforming Military Command Arrangements: The Case of the ...
... WHS- Washington Headquarters Service. ... ie, Army, Navy, Air Force) service publications ... The Case of the Rapid Deployment Joint Task Force. ...
2011-03-01
Plate-boundary earthquakes have occurred repeatedly in the past several thousand years at the Cascadia subduction zone, where they are widely recorded ... ...
ROUNDUP - Johnson Space Center - NASA
Sep 12, 1975 ... POCKET CALCULATORS. Jose P. Olivares 35, Robert B. Clowns and ... of pocket calculators and has an- Washington to arrive by Nov. 20. ...
REDUCTION OF INORGANIC COMPOUNDS WITH MOLECULAR HYDROGEN BY MICROCOCCUS LACTILYTICUS II.
UK PubMed Central (United Kingdom)
Woolfolk, C. A. (University of Washington, Seattle). Reduction of inorganic compounds with molecular hydrogen by Micrococcus lactilyticus. II. Stoichiometry with inorganic...Full Text Available
1962-10-01
Multinational C2 Experiments Supported by C2 Systems and ...
... WHS- Washington Headquarters Service ... but also with respect to other Joint, National and ... unit of action (UA) combat team or task force is organized ...
2003-06-01
Influence: Maximizing Effects to Create Long-Term Stability
... WHS- Washington Headquarters Service. ... The dynamic Joint Special Operations Task Force -- Philippines (JSOTF-P) has evolved and ...
2010-05-03
HYPSOGRAPHY FOR THE FOLLOWING QUADS ALEXANDRIA, FALLS CHURCH, WASHINGTON WEST, MOUNT VERNON, ROCKVILLE, SENECA AND VIENNA. COVERAGE CONTAINS ATTRIBUTES DEFINING OWNERSHIP....
How Can Political Campaign Strategy be Adopted to Support ...
... WHS- Washington Headquarters Service ... present a framework based on political campaigns theory for both the Joint Task Force Commander down ...
2010-10-27
HPLC Phytoplankton Pigment Measurements ... - Ocean Color - NASA
CHORS, SDSU. OCRT Meeting (Washington, D.C., 14-16 Apr 2004). HPLC Phytoplankton Pigment Measurements: Continuation of Climate Quality Data Records ...
Foundational Principles for Organizing a Joint Force Staff
... Chiefs of Staff, Joint Operation Planning and Execution System (JOPES) Volume I, Planning and Procedures, CJCSM 3122.01A (Washington, DC ...
2009-03-18
Download - NASA History Office
Jan 14, 2004 ... presented to the nation at NASA Headquarters, Washington, D.C., ...... Board/Air Force Scientific Advisory Board Joint Task Force on ...
Deja vu: The Unified Command Plan of the Future Revisited
... WHS- Washington Headquarters Service. ... The standing Joint Task Force concept should be used more to provide warfighter forces and ...
2011-05-19
Defense.gov News Article: Exercise Preps 82nd Airborne ...
... Exercise Preps 82nd Airborne Division Staff for Afghanistan Deployment. By Donna Miles American Forces Press Service. WASHINGTON, Nov. ...
Automated Pharmacy Patient Medication Profiling System
UK PubMed Central (United Kingdom)
The Systems Development Group and the Pharmacy Service of the Washington D.C. VAMC are involved in automating the administrative and clinical data requirements of a satellite out-patient pharmacy....Full Text Available
1981-11-04
2010 Secretary Clinton's Remarks
DC -11/29/10 Remarks to the Press on Release of Purportedly Confidential Documents by Wikileaks; Secretary of State Hillary Rodham Clinton; Treaty Room; Washington, DC -11/29/10...
2011-09-18
Energy Technology Data Exchange (ETDEWEB)
Studies conducted at the Pacific Northwest National Laboratory (PNNL) in Richland, Washington have focused on developing and evaluating the reliability of nondestructive testing (NDT) approaches for coarse-grained stainless steel reactor components. The objective of this work is to provide information to the United States Nuclear Regulatory Commission (NRC) on the utility, effectiveness and limitation of NDT techniques as related to inservice testing of primary system piping components in pressurized water reactors. We examined cast stainless steel pipe specimens containing thermal and mechanical fatigue cracks located close to the weld roots and having inner and outer diameter surface geometrical conditions that simulate several water reactor primary piping configurations. In addition, segments of vintage centrifugally cast piping were examined to characterize the inherent acoustic noise and scattering caused by grain ...
2007-01-01
Guide to UK renewable energy companies 2001. 6. ed.
International Nuclear Information System (INIS)
This 2001 edition of the guide to UK renewable companies and equipment and service providers presents summaries of the different industry sectors covering wind power, photovoltaics, solar water heating, geothermal heat pump, hydroelectric power, marine current and wave technology, bioenergy, power generation from landfill gas, energy from waste, and cogeneration. A UK company classification listing and index is provided along with listing of UK organisations and companies and an index of advertisers.
International Nuclear Information System (INIS)
In the case of a release of residual power and fragmenting following a hypothetical accident the applied powers are small. The boiling in the fluid in the bed promotes leveling and the angles of repose obtained are very small. For a specific power in water of 3.1 W/cm_3 a limiting angle of repose of less than 2 degrees is obtained after a time interval of between 1 and 3 hours. EDULCOREE-and ETABUL-research programs are carried out. (DG).
Crumbling case for nuclear power
Energy Technology Data Exchange (ETDEWEB)
In connection with the Public Inquiry into the CEGB proposal to build a pressurised water reactor at Sizewell in Suffolk, the case for nuclear power is examined under the headings: the economics of nuclear power - how they would like them to be; systems analysis - net effective cost; CEGB prejudices the results (comparison with coal-fired plants; forecasting on various assumptions); discounting future costs; back-end costs soar (reprocessing); real reprocessing costs; AGR costs balloon.
1983-01-01
Energy Technology Data Exchange (ETDEWEB)
Passage through dams is a major source of mortality of anadromous juvenile salmonids because some populations must negotiate up to eight dams in Columbia and Snake rivers. Dams cause direct mortality when fish pass through turbines, but dams may also cause indirect mortality by altering migration conditions in rivers. Forebays immediately upstream of dams have decreased the water velocity of rivers and may contribute substantially to the total migration delay of juvenile salmonids. Recently, Coutant (2001a) suggested that in addition to low water velocities, lack of natural turbulence may contribute to migration delay by causing fish to lose directional cues. Coutant (2001a) further hypothesized that restoring turbulence in dam forebays may reduce migration delay by providing directional cues that allow fish to find passage routes more quickly (Coutant 2001a). Although field experiments have yielded proof of the concept of using induced ...
2005-07-01
Behaviour of the steam generators in the Belgian nuclear power plants
International Nuclear Information System (INIS)
After a brief review of the degradations occurring on tubes of Inconel 600 in steam generators of PWR power stations emphasis is put on the conditioning of the secondary water and more particularly on the condensate treatment in the units of Doel which work on heavily polluted brackish water. The important role of non-destructive testing and eddy-current testing is also pointed out, method developed by Laborelec. The operational experience shows that Belgian stations are nearly not concerned by the degradations mostly found in power stations in other countries which shows the efficiency of the conditioning of the secondary water. On the other hand, other problems have occurred, resulting from: damage caused by foreign objects; fouling of tube before commissioning, cracking of bends and at the limit of the dudgeoning and leaking plugs. (AF).
1986-04-15
International Nuclear Information System (INIS)
The circulating cooling water flowrate of GNPS and LNPS is totally about 190 m"3/s. Both stations are located on the western coast of semi-closed Daya Bay. A lot of studies concerning thermal impact of GNPS and LNPS have been carried out since 1987, including mathematical model, physical model, on-site survey and satellite remote sensing, etc. This paper describes the hydrological features of Daya Bay and discharge characteristics of circulating water of GNPS and LNPS, estimates the actual thermal impact of GNPS and LNPS, and indicates that it is advantageous for the dilution of circulating water while the two discharge channels of GNPS and LNPS are combined together towards east
2004-05-01
Road maps on research and development plans for water chemistry of nuclear power systems
International Nuclear Information System (INIS)
Water chemistry of nuclear power plants has played an important role in reduction of personnel doses, structural materials and fuel integrity assurance, and reduction of radioactive wastes production. Further contributions are requested for advanced utilization of the LWR, advanced fuels and aging management of plants. Since water chemistry has an effect on all structure and materials immersed and at the same time affected by them, the optimum control not sticking to specific issues and covering the whole plant is required for these requests. Taking account of roles and activities of the industry, governmental institutes and academia, road maps on research and development plans for water chemistry were compiled into identified eleven items with targets and counter measures taken, such as common basic technologies, dose reduction, SCC mitigation, fuel cans corrosion/hydrogen absorption mitigation, ...
2008-05-01
Pharmaceutical Sciences - Elsevier
...Resort and Convention Center, National Harbor, Maryland, USA September 18-20, 2011 XX HELSINKI DRUG RESEARCH CONGRESS Helsinki, Finland October 23-27, 2011 2011 AAPS Annual Meeting and Exposition Washington Convention Center Washington, DC June 26-29 2012 10th International Symposium on Pharmaceutical Sciences Ankara, Turkey Printer-friendly version Home | Elsevier ...
Interim remedial measures proposed plan for the 200-ZP-1 Operable Unit, Hanford Site, Washington
Energy Technology Data Exchange (ETDEWEB)
The purpose of this interim remedial measures (IRM) proposed plan is to present and solicit public comments on the IRM planned for the 200-ZP-1 Operable Unit at the Hanford Site in Washington state. The 200-ZP-1 is one of two operable units that envelop the groundwater beneath the 200 West Area of the Hanford Site.
1993-12-01
Climate change and water resources in Britain
International Nuclear Information System (INIS)
This paper explores the potential implications of climate change for the use and management of water resources in Britain. It is based on a review of simulations of changes in river flows, groundwater recharge and river water quality. These simulations imply, under feasible climate change scenarios, that annual, winter and summer runoff will decrease in southern Britain, groundwater recharge will be reduced and that water quality - as characterised by nitrate concentrations and dissolved oxygen contents - will deteriorate. In northern Britain, river flows are likely to increase throughout the year, particularly in winter. Climate change may lead to increased demands for water, over and above that increase which is forecast for non-climatic reasons, primarily due to increased use for garden watering. These increased pressures on the water resource base will ...
1998-05-01
Climate change/variability implications on hydroelectricity generation in the Zambezi River Basin
British Library Electronic Table of Contents (United Kingdom)
The study has analysed the effects of various factors on hydroelectric power generation potential to include climate change/variability, water demand, and installation of proposed hydroelectric power schemes in the Zambezi River Basin. An assessment of historical (1970?2000) power potential in relation to climate change/variability at existing hydro electric power schemes(Cahora Bassa, Kariba, Kafue Gorge and Itezhi-Tezhi) in the Zambezi River Basin was conducted. The correlation of hydroelectric power potential with climate change/variability aimed at observing the link and extent of influence of the latter on the former was investigated. In order to predict the future outlook of hydro electric power potential, General Circulation Models (GCM) were used to generate projected precipitation...
2011-01-01
Environmental impacts of nuclear and coal-fired power plants
International Nuclear Information System (INIS)
The current situation in the development of nuclear power in the world and in Czechoslovakia is briefly outlined and the possibilities are discussed of alternative energy resources. The environmental impact is described of conventional power plants firing coal; sulphur and nitrogen oxides are mentioned and their environmental impacts shown. Their quantities and the quantities of other gaseous, liquid and soid wastes produced by coal power plants are given. Annual estimates are presented of radioactive material emissions; trace amount emissions of toxic metals and their ecological risks are shown. Concern over the increasing concentration of CO_2 in the atmosphere is voiced. For nuclear power plants, the amount of radionuclides in stack emission and of those released into water flows is tabulated. Their effect on the aqueous ecosystem is characterized as is thermal pollution of ...
1984-01-01
International Nuclear Information System (INIS)
... 978-5-94883-072-8 121 p. SPECIFIC NUCLEAR REACTORS AND
International Nuclear Information System (INIS)
The guide describes a method acceptable to the NRC staff for complying with the Commission's regulations with regard to quality assurance requirements for installation, inspection, and testing of mechanical equipment and systems for water-cooled and high-temperature gas-cooled nuclear power plants.
Incident report: spillage of reactor coolant at Wolsung
Energy Technology Data Exchange (ETDEWEB)
Late last year the Wolsung Candu in Korea suffered an incident which resulted in heavy water being released from the primary system into the containment. With the unit now back at full power, this article examines the causes of the incident and the action which is being taken to prevent it happening again.
1985-05-01
Final Report of ''On-the-Job Training'' on the CANDU Reactor.
This is the final Report for the technical ''on-the-job traning'' for the Wolsung CANDU nuclear power plant which is the first Pressurized Heavy Water Reactor setting up in Korea. The technical ''on-the-job traning'' was established to increase the capabi...
1983-01-01
Evaluation of field application of boric acid
International Nuclear Information System (INIS)
Results of field applications of boric acid in the secondary coolant circuits of seven PWR units for the purpose of reducing the rate of corrosion denting are reported. Based on available data at the power plants considered in this study, it was not possible to support or refute the benefit of using boric acid secondary water treatment.
1985-03-01
Development of Tritium Removal Technology.
Liquid Phase Catalytic Exchange (LPCE)- Cryogenic Distillation(CD) process was studied which could be available for an optimal tritium removal process of pressurized heavy water reactor system at Wolsung nuclear power plant in the near future. Based upon ...
1986-01-01
International Nuclear Information System (INIS)
Power plant components exposed to environments such as water and soil are susceptible to severe corrosion. Many times the effect of corrosion in power plant components can be catastrophic. The problem is aggravated for underground pipelines due to additional factors such as large network of pipelines, proximity to earth mat, high voltage transmission lines, corrosive chemicals, inadequate approach etc. Other components such as condenser water boxes, internals of pipelines, clarifier bridge structures, cooling water inlet gates and pipes etc. which are in continuous contact with water, are subjected to severe corrosion. The nature and locations of all such components are at places which are not accessible for routine maintenance and hence they require long term reliable protection against corrosion. Experience has shown that anti-corrosive coatings are inadequate ...
1999-11-22
Studies on the CRUD Deposition on Fuel Cladding Surface Using AOA Water Chemistry Loop
International Nuclear Information System (INIS)
Axial offset anomaly (AOA) is caused by the deposition of crud on the fuel cladding of a PWR. When significant levels of crud build up on the cladding, boron can accumulate in the pores of the crud as a concentrated solution or solid phase, and cause the flux depression. Numerous studies have been conducted on the primary water chemistry to reduce the amount of crud in the primary circuit to avoid radioactivity buildup and unexpected power transition in the plant. However, experiments on the crud are restricted in the laboratory because the crud is a highly radioactive material. The objective of this study is to develop a test method for simulating the deposition of crud in a nuclear power plant
2010-10-01
Some studies on physics parameters of Wolsung unit no. 1
International Nuclear Information System (INIS)
Nuclear physics parameters of the Wolsung CANDU-PHW reactor are computed by use of the PHWCELL computer code that is an improved version of LATREP. The PHWCELL code mainly computes cell parameters of heavy water moderated reactors, and modeling scheme of heavy water reactor cell calculations has been developed with the PHWCELL computer code. The reactor operating conditions considered in the study are cold zero power (CZP) and hot full power (HFP) with equilibrium poison. The cell parameters are also computed as a function of fuel burnup and the numerical results are compared with the results in PSR of the Wolsung unit and in the previous study. (author).
1980-01-01
A horizontal steam generator for the Indian 235 MW heavy water nuclear power plants
International Nuclear Information System (INIS)
In this paper the thermal design of a horizontal steam generator for the Indian PHWR nuclear power plant is described. The main attraction is absence of tube sheet and use of stainless steel 'U' tubes. It is emphasised that with appropriate water chemistry it is possible to use stainless steel tubes, which is many times cheaper than the Incoloy tubes used elsewhere. The design approach, applicable equation for the design and the results of computation in the form of heat transfer area and some important dimensions of the steam generator are presented.
1993-11-01
Overview of Cooling Water System for the KSTAR 1st Plasma Experiment
International Nuclear Information System (INIS)
The KSTAR cooling water system (CWS) consists of a primary cooling water system (PCWS), a secondary cooling water system (SCWS), and a de-mineralizing and de-ionized water system (DIWS). The PCWS cooling loops have been made for the poloidal field (PF) and toroidal field (TF) magnet power supplies (MPS), vacuum vessel (VV), electron cyclotron heating (ECH), ion cyclotron heating (ICRH), vacuum pumps, diagnostics, helium facility, etc. The CWS had been done individual commissioning of each system to confirm the design specifications by the end of 2006 and had gradually begun operation for the KSTAR ancillary devices by March 2008
2009-05-01
Energy Technology Data Exchange (ETDEWEB)
12 kind of environmental samples such as soil, underground water, seawater, etc. around the Nuclear Power Plants(NPP) and surface seawater around the Korea peninsula were sampled, For the samples of rain, pine-needle, air, seawater, underground water, chinese cabbage, grain of rice and milk sampled around NPP, and surface seawater and rain sampled all around country, tritium concentration was measured, The tritium concentration in the tap water and the gamma activity in the domestic and imported beef that were sampled at ward in the large city in Korea(Seoul, Pusan, Taegu, Taejun, Inchun, Kwangju) were analyzed for the meat and drinking waters. As the results of analyzing, tritium concentration in rain and tap water were very low all around country, but a little higher around the NPP than general surrounding. At the Wolsung NPP, tritium concentration was descend ...
2001-12-15
Hybrid solution and pump-storage optimization in water supply system efficiency: A case study
International Nuclear Information System (INIS)
Environmental targets and saving energy have become ones of the world main concerns over the last years and it will increase and become more important in a near future. The world population growth rate is the major factor contributing for the increase in global pollution and energy and water consumption. In 2005, the world population was approximately 6.5 billion and this number is expected to reach 9 billion by 2050 [United Nations, 2008. (www.un.org), accessed on July]. Water supply systems use energy for pumping water, so new strategies must be developed and implemented in order to reduce this consumption. In addition, if there is excess of hydraulic energy in a water system, some type of water power generation can be implemented. This paper presents an optimization model that determines the best hourly operation for 1 day, according to the electricity ...
2008-11-01
Energy Technology Data Exchange (ETDEWEB)
Olive oil mill wastewaters (OMW) cause disposal problems because they contain powerful pollutants such as phenolic compounds. Complete biodegradation or removal of these compounds is hardly achieved by a single treatment method. In this work, we investigated 2 integrated technologies for the treatment of the recalcitrant contaminants of OMW, allowing water recovery and reuse for agricultural purposes. (Author)
2009-07-01
British Library Electronic Table of Contents (United Kingdom)
Results are given of numerical simulation of three-dimensional pattern of flow of a two-phase steam-water mixture in the house of a PGV-1000 horizontal steam generator obtained using the BAGIRA best-estimate thermohydrodynamic computer codes. The space distributions of velocities and local void fractions in the steam generator housing for different modes of operation of power-generating unit are calculated and compared with available experimental data.
2008-01-01
Results are given of numerical simulation of three-dimensional pattern of flow of a two-phase steam-water mixture in the house of a PGV-1000 horizontal steam generator obtained using the BAGIRA best-estimate thermohydrodynamic computer codes. The space distributions of velocities and local void fractions in the steam generator housing for different modes of operation of power-generating unit are calculated and compared with available experimental data.
2008-05-01
The solar array wings were deployed by swinging two half-blanket boxes open from a folded hinge launch position .... pure-water by-product of the shuttle's fuel cell power generators because ..... outgassing limits, flammability limits, ... Foale fills a water microbiology bag for in-flight analysis. ...
Doublet III limiter/armor update
Energy Technology Data Exchange (ETDEWEB)
The Doublet III device is operating with an extensive system of plasma limiters and wall protective armor. Operations with up to 8MW of neutral beam power and 1.5MA plasma current are planned. Design and operational performance of the following systems are discussed: 1. Water-cooled graphite moveable limiter. 2. Water-cooled graphite fixed limiter and neutral beam wall armor. 3. Radiatively cooled Inconel divertor plates.
1983-12-01
Direct measurements of secondary water inventory of steam generator PGV-213 in operation
Energy Technology Data Exchange (ETDEWEB)
Results of weight measurement of PGV-213 steam generator during filling in, heating-up and power increase are described. Special measurement system based on stress gauges has been developed. Method of derivation of secondary water inventory is described. Comparison of the data for two steam generators prove accuracy of the measurements. (orig.). 1 refs.
1997-12-31
A computer program for estimating decommissioning costs for light water reactors
Energy Technology Data Exchange (ETDEWEB)
This report discusses a desk-top computer program has been developed for estimating the costs, waste volumes, and occupational radiation exposures associated with decommissioning light-water reactor power stations. Cost categories and cost algorithms used in the program are discussed and a brief description of the user interface is given.
1993-02-01
Energy Technology Data Exchange (ETDEWEB)
The chemical operational concept originally established for the water-steam circuit of Angra II nuclear power plant has undergone several modifications throughout the development of the project. This work discusses the two main modifications giving special attention to the costs involved and analyses the main points and the consequences of such modifications 1 ref., 4 figs., 2 tabs.
1995-12-31
Energy Technology Data Exchange (ETDEWEB)
The river Saale cascade consists of seven reservoirs with a total capacity of approx. 415 Mio. m[sup 3]. The entire reservoir system covers a catchment area of 1665 km[sup 2]. The water management tasks extend to the following main fields: flood protection upkeep of minimum water stock, salt load control and power generation. The energy supply capacity of the cascade is mainly used by pumped storage plants. The last of these plants, Hohenwarte II, was put into service in 1963. (orig.)
1993-01-01
The SBWR (simplified boiling water reactor) thermal-hydraulic performance analysis and testing
Utility interest has recently increased in potential future nuclear units that combine the characteristics of smaller size, greater simplicity, and more passive safety features. In response to such interest, General Electric (GE) began development in 1982 of a 600-MW(electric) reactor with simplified power generation and safety systems. This paper provides an overview of the simplified boiling water reactor (SBWR) design, with emphasis on the thermal-hydraulic aspects of the design. The SBWR is a natural circulation reactor requiring no pumps to circulate the water through the core.
1989-11-01
French power for Jersey goes under water
Energy Technology Data Exchange (ETDEWEB)
A proposed project by which the island of Jersy could buy electric power from France is discussed. The interconnector will be capable of transmitting up to 50MW. Included in the project will be 27 km of submarine cable and 23 km of underground cable. An oil-filled cable containing 120 mm diameter copper conductors and weighing 47 kg/m is used. Details of the installation and oil system are given.
1983-01-21
Public power's roots deep in the Northwest
Energy Technology Data Exchange (ETDEWEB)
Municipal power systems developed early in the Pacific Northwest, but a new dimension was added in the 1930s when the public utility district (PUD) concept combining urban and rural areas encited vigorous debate and the public rejected private-utility candidates. A favorable national climate developed for consumer-owned systems during the 1920s and 30s encouraging the passage of the Federal Water Power Act, the creation of the Tennessee Valley Authority, the building of Hoover Dam, and the establishment of the Bonneville Power Administration. This article reviews developments following the Public Utility Act of 1935, which authorized the Federal Power Commission and the uniform system of accounts. After tracing the record of investigations and policy trends during the Roosevelt era, it concludes that utilities benefited from accounting regulations. (DCK)
1982-01-01
Energy Technology Data Exchange (ETDEWEB)
Many power plants use treated surface water as boiler feedwater and have difficulties in keeping within the limits for organic substances in feedwater (TOC < 200 ppb) or acid conductivity in steam condensate (< 0.2 {mu}S/cm). The characteristics of surface water and the role of organic substances in boiler feedwater are explained and discussed. [German] Viele Kraftwerke bereiten fuer die Erzeugung von Kesselspeisewasser Oberflaechenwasser auf und haben Probleme, die Richtlinien fuer organische Stoffe im Speisewasser (TOC < 200 ppb) oder Saeure-Leitfaehigkeit in Dampfkondensaten (< 0,2 {mu}S/cm) einzuhalten. Die besonderen Eigenschaften von Oberflaechenwaessern und die Bedeutung organischer Stoffe in Kesselspeisewasser werden erlaeutert und diskutiert. (orig.)
2000-07-01
UK's Sizewell inquiry; funny how time slips away
Energy Technology Data Exchange (ETDEWEB)
Comments are made on the Public Inquiry into CEGB's proposal to construct a pressurized water reactor (PWR) at Sizewell, UK. Aspects discussed include: time elapsed and its possible effect on the result; economics of nuclear power plants compared with coal-fired power plants; changes in real sterling/dollar exchange rates; effect of mineworkers' strike; the UK electric power generating system; AGR reactors compared with PWR reactors; extension of Magnox reactor life; radioactive waste management; political decisions.
1985-03-01
NPD Canada's first nuclear power station
Energy Technology Data Exchange (ETDEWEB)
This talk reviews the history of the Canadian nuclear-electric program highlighting Canada's first nuclear power station, the Nuclear Power Demonstration or NPD. NPD was commissioned and delivered electricity to Canadian consumers for the first time on june 4, 1962. The Canadian nuclear-electric program is based on the CANDU-PHW (Canadian Deuterium Uranium - Pressurized Heavy Water) concept which was conceived between 1955 and 1958 at the Chalk River Nuclear Laboratory (CRNL) of AECL, located a few miles from Deep River. This talk covers the history of the Canadian nuclear-electric activities dating back to 1939.
2002-07-01
Atomic power of Germany and ecology
International Nuclear Information System (INIS)
The NPPs safety system in Germany is discussed. It is shown that there exists no threat for the German NPPs at the peace times. They release insignificant quantities of radioactive substances into the water and atmosphere. The average equivalent dose constitutes 0.0005 mSv annually. The annual equivalent dose for the personnel is equal to 4.4 mSv. At the same time, the NPPs contribute to a certain degree to the environmental medium improvement, preventing the ingress therein of the sulfur and carbon dioxide, dust and nitrogen oxides by application of fossil fuels. Attention is also paid to reprocessing facilities and also to the nuclear fuel wastes disposal. The advantages of the nuclear power engineering in comparison with the fossil fuel power engineering are enumerated
Advanced resin cleaning system
International Nuclear Information System (INIS)
Novel and unprecedented ion exchange resin cleaning system, for use in BWR plants and featuring a vibration separator and basic design factors of Radiological Solutions, Inc., had been delivered to Tokai No. 2 Power Station, Japan Atomic Power Company, in October 2005. This compactly-designed system effectively separates crud and resin fines from ion exchange resins, with no clogging of separation screens. It generates minimized waste liquid and has a specially designed over-pack cleaning tank. The system has been in operation for about 2 years and half now and favorable operational data, such as crud and sulfate concentration decrease in feed water and reactor water respectively, and evaluation results have been reported from Japan Atomic Power Company and so on. (author)
2008-07-01
Dynamic load in suppression pool during BWR main steam safety relief valve actuation
International Nuclear Information System (INIS)
BWRs are so designed that the exhaust steam from main steam safety relief valves is led to pressure suppression pools, and the steam is condensed in pool water, but at this time, dynamic load seems to arise in the pool water. In Tokai No. 2 Power Station, a Mark-2 containment vessel was adopted to improve the reliability as much as possible and to obtain the design with margin. In this report, the result of actual machine test in Tokai No. 2 Power Station and the method of reducing the load are described. When a relief valve works, the discharge of water in exhaust pipes into a suppression pool, the exhaust of air in exhaust pipes and repeated expansion and contraction of bubbles in pool water, and the exhaust of steam and condensation occur. As for the construction of the suppression pool in Tokai No. 2 Power Station, cross-shaped quencher ...
1979-01-01
Energy Technology Data Exchange (ETDEWEB)
In 1996, the National Marine Fisheries Service and the University of Washington completed the fourth year of a multi-year study to estimate survival of juvenile salmonids (Oncorhynchus spp.) passing through dams and reservoirs on the Snake River. Actively migrating smolts were collected near the head of Lower Granite Reservoir and at Lower Granite Dam, tagged with passive integrated transponder (PIT) tags, and released to continue their downstream migration. Individual smolts were subsequently detected at PIT-tag detection facilities at Lower Granite, Little Goose, Lower Monumental, McNary, John Day and Bonneville Dams. Survival estimates were calculated using the Single-Release (SR) and Paired-Release (PR) Models. Timing of releases of tagged hatchery steelhead (O. mykiss) from the head of Lower Granite Reservoir and yearling chinook salmon (O. tshawytscha) from Lower Granite Dam in 1996 spanned the major portion of their juvenile migrations. Specific research ...
1998-02-01
Sources of toxicity and exposure information for identifying chemicals of high concern to children
International Nuclear Information System (INIS)
Due to the large number of chemicals in commerce without adequate toxicity characterization data, coupled with an ineffective federal policy for chemical management in the United States, many states are grappling with the challenge to identify toxic chemicals that may pose a risk to human health and the environment. Specific populations (e.g., children, elderly) are particularly sensitive to these toxic chemicals. In 2008, the Children's Safe Product Act (CSPA) was passed in Washington State. The CSPA included specific requirements to identify High Priority Chemicals (HPCs) and Chemicals of High Concern to Children (CHCCs). To implement this legislation, a methodology was developed to identify HPCs from authoritative scientific and regulatory sources on the basis of toxicity criteria. Another set of chemicals of concern was then identified from authoritative sources, based on their potential exposure to children. Exposure potential was evaluated by identifying ...
2010-11-01
Energy Technology Data Exchange (ETDEWEB)
An initial review was conducted of the current treatment operations for remediation of groundwater contaminated with trichloroethene (TCE) at the Fort lewis Logistics Center. Results from this review indicate the two pump-and-treat systems are effectively containing the TCE plume within the upper unconfined aquifer (Vashon Drift). However, mass balance calculations show the existing treatment systems alone will not accomplish the remedial action objective of cleaning up the aquifer to drinking water standards within 30 years as specified in the Record of Decision (ROD). This conclusion is based on the estimated mass of TCE at the source term (51,000 kg), the calculated mass of TCE in the aquifer (4,900 kg), and the removal rate of the pump-and-treat systems that currently ranges from 324 to 667 kg of TCe per year. Four areas within the TCE plume have been identified where enhancements could be made to the existing treatment operations. These are, Area 1 -- the ...
1998-07-01
Energy Technology Data Exchange (ETDEWEB)
Developing and deploying innovative environmental cleanup technologies is an important goal for the U.S. Department of Energy (DOE), which faces challenging remediation problems at contaminated sites throughout the United States. Achieving meaningful, constructive stakeholder involvement in cleanup programs, with the aim of ultimate acceptance of remediation decisions, is critical to meeting those challenges. DOE`s Office of Technology Development sponsors research and demonstration of new technologies, including, in the past, the Volatile Organic Compounds Arid Site Integrated Demonstration (VOC-Arid ID), hosted at the Hanford Site in Washington State. The purpose of the VOC-Arid ID has been to develop and demonstrate new technologies for remediating carbon tetrachloride and other VOC contamination in soils and ground water. In October 1994 the VOC-Arid ID became a part of the Contaminant Plume Containment and Remediation Focus Area (Plume ...
1995-05-01
Wax and hydrate control with electrical power
Energy Technology Data Exchange (ETDEWEB)
Electrical heating of subsea flowlines is an effective way to prevent wax and hydrate information, especially for long transportation distances and in low-temperature deep water. Systems are available for use in conjunction with bundles, pipe-in-pipe, and wet-thermal-insulation systems. These systems provide environmentally friendly fluid-temperature control without chemicals or flaring for pipeline depressurizing. Enhanced production is achieved because no time is lost by unnecessary depressurizing, pigging, heating-medium circulation, or removal of hydrate and wax blockages. The seabed temperature at 100-m and greater water depths may range from 7 to {minus}1.5 C, causing a rapid cooling of the hot well streams being transported in subsea flowlines. Under these supercooling conditions, vulnerable crude oils and multiphase compositions will deposit wax and asphalts; also the gas/water phase may freeze solid with hydrate ...
1997-08-01
Water induction studies in a hydrogen-diesel dual-fuel engine
Energy Technology Data Exchange (ETDEWEB)
Power output of a hydrogen-diesel dual-fuel engine is limited by the onset of knock as the percentage of heat input derived from hydrogen increased beyond a certain limit. Earlier work carried out at the Internal Combustion Engines Laboratory, Indian Institute of Technology, Madras, indicates that this knock sets in when the induced hydrogen exceeds about 60% of input energy at a pilot diesel quantity of 30% of full load diesel amount. At higher rates of hydrogen induction, the richer hydrogen-air mixture is more prone to knocking. Hardly any information is available on the possibilities of improving the knock limited power output of a hydrogen-diesel dual-fuel engine. Water can serve as a powerful internal coolant in decreasing the unburned mixture temperature because of its high latent heat. This paper presents the results of our investigation on improving the knock limited power ...
1987-01-01
Energy Technology Data Exchange (ETDEWEB)
Due to its important hydroelectric power generation facilities (about 525 plants with a total power of 13,314 MW producing about 35.3 TWh annually) Switzerland plays an important role in the interconnected European power system. Large artificial storage lakes in the Swiss Alps can generate peak power during hours of highest demand: 9700 MW are available from accumulated energy and the total power of pumped-storage facilities amounts to 1700 MW. The latter allow refilling the reservoirs at periods of low power demand and generating power at periods of peak demand. In the case of favorable conditions, the yearly average power production could be increased by 6% and the production during the winter period (October to March) by 20% by the year 2020. However, looking forward to the year 2050, the annual production is expected ...
2007-07-01
Energy Technology Data Exchange (ETDEWEB)
A series of copolymers based on the cellulose acetate/propionate-g.co-acrylic acid system has been prepared under radiation-induced control. These copolymers have been assessed for their water-retention capacity both in an unmodified state and after ''decrystallization'' or ''neutralization'' treatments. The grafting of acrylic acid onto the cellulose acetate/propionate had little effect on the water retention power of the cellulose acetate/propionate. However, improvements to the water retentivity was obtained after ''decrystallization'' procedures had been carried out on the copolymers using selected alkali metal salts with methanol as the continuous medium. The water-retentivity of the copolymers increased with increase in the extent of grafting, though the effect is less ...
1990-01-01
Computer programs have been developed to define the temperature increase which would be needed to bring deep-ocean water into density equilibrium with surface water for locations where data are available. A series of continuous-flow studies on phytoplankton blooms resulting from mixtures of 80 percent deep and 20 percent surface water in 2000-liter concrete culturing vessels (''reactors'') has been completed. A quantitative determination of nutrient utilization and flow through a combined primary and secondary trophic level system has been completed. This study utilized the clam Tapes semidecussata, fed from phytoplankton grown in 80 percent deep and 20 percent surface water. An analysis of the fate of the deep water discharged from a floating OTEC plant indicates that horizontal containment of the resulting deep water: ...
1976-01-01
Condensation driven water hammer studies for feed water distribution pipe
International Nuclear Information System (INIS)
Special T-shaped feedwater distribution pipes were installed in steam generators at the Loviisa (Finland) and Rovno (Russia) nuclear power plants. The new shape was tested in an extensive testing programme. Since the tubes frequently suffer from corrosion damage, large-scale water hammer experiments were performed on a model facility in 1996. The main objectives of the water hammer experiments were to find out the prevailing parameters leading to water hammers, as well as the sensitivity of hammering to boundary conditions. A water hammer may occur when the mass flow rate into the steam generator exceeds 6 kg/s and the temperature difference between steam generator and feedwater exceeds 100 degC. Visual experiments and stress analyses of the pipe were also carried out. The weakest part, the T-joint, may hold against such water hammers only for a limited time of ...
1997-05-26
Reducing the costs of ultrapure water production - a case study
Energy Technology Data Exchange (ETDEWEB)
The 380 MW combined cycle gas turbine power station in Peterborough changed its water supply from town mains to high purity reverse osmosis permeate in October 2000. The high purity water is produced from secondary treated sewage effluent using advanced membrane technology. Alpheus Environmental and British Gas staff have recently completed a study of the power station's demineralization plant to identify the differences in operating costs associated with the change in feedwater. The results show that the ultrapure water produced after the change to a high purity feed is of improved quality and that the demineralization plant regeneration operating costs have been reduced by over 90%. The demineralization plant availability has increased from 78 to 98% enabling almost 20% more ultra pure water to be produced. The change in feedwater has also improved ...
2002-02-01
Operational safety experience and passive safety testing at the FFTF
International Nuclear Information System (INIS)
The FFTF is a 400-MWt sodium-cooled fast neutron flux test reactor located on the US government-owned Hanford Site in southeastern Washington state. The reactor is operated for the US Department of Energy by the Westinghouse Hanford Company. Since FFTF started routine operation in 1982, the commercially fabricated driver fuel has performed flawlessly to well beyond the design goal peak burnup of 80 MWd/kgM. The core average discharge exposure is now some 60% beyond the original design expectations and attests to the ruggedness and reliability of the mixed oxide fuel system. In Cycle 9 sixteen long-life assemblies were installed to begin the irradiation of mixed oxides in the advanced low-swelling alloy HT-9 as the Core Demonstration Experiment (CDE). Operation of the plant from initial startup testing to ten cycles of operation has confirmed that the nuclear characteristics are well within the design predictions, and all parameters have remained inside the ...
1987-10-21
FFTF operational results: startup to 100 MWd/kg
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a 400-MW(t) sodium-cooled fast reactor operating at the Hanford Engineering Development Laboratory in Richland, Washington, to conduct fuels and materials testing in support of the US liquid-metal fast breeder reactor program. Startup and initial power testing included a comprehensive series of nuclear and nonnuclear tests to verify the thermal and neutronic characteristics of the plant and to demonstrate its inherent safety features. Extensive reactor core characterization measurements were completed to provide the neutron and gamma spectra, fission rates, and other physics data needed to design and evaluate tests irradiated in the FFTF. A specially designed series of natural-circulation tests was performed to demonstrate the inherent safety features of the plant. Early in 1982 the FFTF began its first 100-d irradiation cycle. Since that time the plant has operated beyond expectations; it achieved a cycle ...
Augmented Fish Health Monitoring; Volume II of II, Completion Report.
Energy Technology Data Exchange (ETDEWEB)
The Bonneville Power Administration (BPA) initiated the Augmented Fish Health Monitoring project in 1986. This project was a five year interagency project involving fish rearing agencies in the Columbia Basin. Participating agencies included: Washington Department of Fisheries (WDF), Oregon Department of Fish and Wildlife, Idaho Department of Fish and Game, and the US Fish and Wildlife Service (USFWS). This is the final data report for the Augmented Fish Health Monitoring project. Data collected and sampling results for 1990 and 1991 are presented within this report. An evaluation of this project can be found in Augmented Fish Health Monitoring, Volume 1, Completion Report.'' May, 1991. Pathogen detection methods remained the same from methods described in Augmented Fish Health Monitoring, Annual Report 1989,'' May, 1990. From January 1, 1990 to June 30, 1991 fish health monitoring sampling was conducted. In ...
1991-12-01
Safety considerations of active process water system shutdown for TAPP - 3 and 4
International Nuclear Information System (INIS)
Active Process Water (APW) System, provided as unitized closed loop system in Tarapur Atomic Power Project Units-3 and 4, serves to remove heat from various heat exchangers. One of the important loads served by APW system is shutdown cooling heat exchangers and if APW shutdown is taken then reactor cannot be maintained in cold shutdown condition. It is estimated that after 7 days of reactor shutdown, if about 20% of the normal cooling flow to shutdown cooling heat exchangers is provided then along with keeping PHT in cold shutdown state, reactor components, moderator, end shield water, calandria vault water and calandria vault concrete temperature can be maintained within technical specification limits for extended duration. (author)
2005-12-01
Laser-Cooling of Liquid Water by the Ar-Xe Laser Radiation
An effect of laser-cooling of water was observed for the first time with a temperature decrease dT = -2.2 K after irradiation of liquid water surface by a powerful Ar-Xe pulse laser with a pulse energy of about 1 J and wavelength L = 1.73, 2.63 and 2.65 um. The discovered effect can apparently be ascribed to the optical excitation of vibrational states of H2O molecules followed by an endothermic consolidation of chemically active excited molecules into a quasi-stable cluster-like structure. The measured time dependences of the cooling effect show that a typical life time of the new state of water amounts to hours. It has also been shown that the life time of the excited vibrational molecular states due to a radiation trapping effect can be estimated to at least hundreds of seconds.
2010-01-01
Influence of O{sub 2} and N{sub 2}H{sub 4} on the ECP in high temperature water
Energy Technology Data Exchange (ETDEWEB)
The ECP of construction materials in the water steam circuits of power plants is influenced by many parameters, including: reactions of oxidants, such as O{sub 2} or dissolved copper species; and reactions of reducing species, namely N{sub 2}H{sub 4}. Electrochemical measurements were performed to clarify the role of hydrazine for the open circuit potential in water/steam circuits. Current density electrode potential curves of the electrochemical oxidation of hydrazine and the reduction of oxygen in aqueous solutions were measured as a function of temperature in the range from room temperature to approximately 260{degrees}C. The electrode materials used were platinum, gold and Alloy 800 mod.. In addition, corrosion potentials were measured in water containing oxygen or hydrazine.
1992-12-31
Web-Based Time Synchronization - Naval Oceanography Portal
Folder Display Clocks Folder TWSTT Folder Loran-C Folder Telephone Time Folder NTP Info Web-Based Time Synchronization Web time displays from the USNO Master Clock, Washington, DC...
2011-10-09
Time Travel Through A Trail Of ... - Near-Earth Object Program - NASA
Dolores Beasley Headquarters, Washington, DC July 19, 2000 (Phone: 202/358- 1753) Bill Steigerwald Goddard Space Flight Center, Greenbelt, MD (Phone: ...
The Harris M. Schurmeier Collection, 1970-1986 3.0 cubic ... - NASA
SDI was a space-based defense system designed to ... satellites that could detect a massive nuclear launch within seconds, orbiting laser weapons to destroy the ..... AIAA Washington Conference, memorandum from T. W. Hamilton to H. ...
T Plant secondary containment and leak detection upgrades
Energy Technology Data Exchange (ETDEWEB)
The W-259 project will provide upgrades to the 2706-T/TA Facility to comply with Federal and State of Washington environmental regulations for secondary containment and leak detection. The project provides decontamination activities supporting the environmental restoration mission and waste management operations on the Hanford Site.
1995-10-19
Predicting Airborne Particle Levels Aboard Washington State School Buses
UK PubMed Central (United Kingdom)
School buses contribute substantially to childhood air pollution exposures yet they are rarely quantified in epidemiology studies. This paper characterizes fine particulate matter (PM2.5)...Full Text Available
2008-10-01
Have a question about CPR? Click Here To Ask The Doctor Learn CPR is a free public service supported by the University of Washington School of Medicine . Learn the basics of CPR - cardiopulmonary resuscitation. The American Heart Association issued updated ...
Geothermal heat-pump systems are competing today against conventional fuels
Energy Technology Data Exchange (ETDEWEB)
The alternative to the use of deeper wells through temperature amplification of the geothermal resource by electric heat pumps is explored. Systems in Ephrata, Washington and Chamberlain, South Dakota are explored. (MHR)
1982-12-01
This document is the published result, conclusion, or progress report of research performed by the staff of the U.S. Geological Survey, Fort Collins Science ... ...
Energy Technology Data Exchange (ETDEWEB)
A characteristic trait of Francis turbines operating at low-head is pressure pulsations that occur during certain load levels of the generator. These stem from pressure variations across the turbine due to pulsating flow in the draft-tube. This surging action of the water column is related to draft-tube geometry and flow-rate of water in the penstock. The pressure pulsations cause torque variations on the turbine and corresponding electric power pulsations. If electric power is used as a feedback signal to the Power System Stabilizer (PSS), then Mvar and terminal voltage pulsations will occur when the generator is operating in the ``rough zone``. This paper describes field test results for investigating feedforward control from the penstock, draft tube and spiral case pressure to reduce the effects of Mw pulsations on PSS output signals. This investigation involved a PSS with ...
1993-12-01
Transient Critical Heat Flux tests on a rod bundle simulating Pressurized Water Reactors
International Nuclear Information System (INIS)
Transients induced in nuclear power plants from many sources result in one or more fluid conditions changing with time. Fluid conditions of pressure, inlet temperature, inlet flow, or even system power many change separately or in conjunction with each other. The result of the condition change may be one which induces departure from nucleate boiling. An experimental investigation of transient which were intended to achieve Critical Heat Flux was performed at the Heat Transfer Research Facility of Columbia University for Siemens Nuclear Power Corporation. The transients were set up to include broad ranges of flow and pressure conditions near the operating range of pressurized water reactors. Transient events were dominated by varying single conditions and measuring the response of the system and of the rod thermocouples. Because of coupling effects within the test loop, secondary conditions would also ...
Environmental restoration remedial action quality assurance requirements document
International Nuclear Information System (INIS)
The environmental Restoration Remedial Action Quality Assurance Requirements Document (DOE/RL 90-28) defines the quality assurance program requirements for the US Department of Energy-Richland Field Office Environmental Restoration Remedial Action Program at the Hanford Site, Richland, Washington. This paper describes the objectives outlined in DOE/RL 90-28. The Environmental Restoration Remedial Action Program implements significant commitments made by the US Department of Energy in the Hanford Federal Facility Agreement and Consent Order entered into with the Washington State Department of Ecology and the US Environmental Protection Agency.
1991-09-08
Status of the surry low power and shutdown PRA
International Nuclear Information System (INIS)
Traditionally, probabilistic risk analyses [PRA] of severe accidents in nuclear power plants have limited themselves to consideration of the set of initiating events occurring during full power operation. However, some analyses of accident initiators during low power, shutdown, and other modes of plant operation other than full power have been performed. These studies as well as the Chernobyl accident and recent operating experience at U.S. pressurized water reactors suggested that risks during low power and shutdown could be significant. As such, the analysis of the frequencies, consequences, and risks of these accidents was identified as one task in the Nuclear Regulatory Commission staff's study of the implications of the Chernobyl accident to U.S. commercial nuclear power plants. The surry PRA project is an ongoing high priority effort ...
1990-10-01
The efficiency of coal-fired combined-cycle powerplants
Energy Technology Data Exchange (ETDEWEB)
Concepts involving combined gas-turbine/steam-turbine power-generation plants, in which the fuel gas for the gas turbine is produced via the gasification of coal, are now extremely advanced. This technology already permits efficiencies of around 50% current development targets view 65% as achievable. In conventional technology, efficiencies are tied to conditions, such as air and cooling-water temperatures, at the particular location. In combined-cycle power plants, the properties of the fuel coal also play an important part. There are, in face, coals which can be more advantageously used in a combined-cycle power plant than in a conventional one. These differences, combined with advantageous concepts for coal-fired combined-cycle power-generating plants, are presented and analyzed. Particular attention is devoted to individual losses occurring at coal conversion, thermodynamic ...
1996-12-01
International Nuclear Information System (INIS)
Design improvements are being incorporated into the heavy water management systems at Wolsong 2,3 and 4 to reduce the load on the vapour recovery driers and upgraders and the heavy water losses via the stack. There will also be improvements to monitor heavy water and tritium releases. This paper describes the improvements, gives background on heavy water balance mechanism, the historical trends for heavy water recovery/losses and estimated dose to the member of the public critical group resulting from the airborne and waterborne releases. The measured tritium activity levels in the heat transport system (HTS) and moderator system at Wolsong 1 are given. Using these activity levels and heavy water loss data, tritium losses from the dried and ventilated areas are estimated. A qualitative assessment of expected heavy water and tritium releases ...
1994-03-01
Energy Technology Data Exchange (ETDEWEB)
Water and mud samples were collected from canals and rivers which were adjacent to outlets discharging warm water of 3 power plants in Berlin. Downstream samples from 1 bathing resort were also collected. Free living amoebae were isolated from 138 water and 69 mud samples. From these respectively 156 and 73 strains could be cultured and were administered intranasally to mice for pathogenicity tests. Two Acanthamoeba strains from water and 7 from mud could be reisolated from mouse brain and or lungs, although no pathological disorders could be observed. Five Naegleria strains were negative in mouse inoculation tests. Four Acanthamoeba strains which were positive in mice were cultured at + 45 degrees C; no cytopathogenic effects were observed in tissue cultures. Acanthamoeba infective for mice could also be isolated from samples at low water temperatures. Further ...
1982-05-01
Integral severe accident analysis of light water nuclear power plants by IMPACT-SAMPSON code
Energy Technology Data Exchange (ETDEWEB)
The NUclear Power Engineering Corporation (NUPEC) has developed IMPACT-SAMPSON code to analyze integral behavior of light water nuclear power plants under severe accident conditions. IMPACT-SAMPSON's distinguishing features include interconnected hierarchical modules and mechanistic models covering a wide spectrum of scenarios ranging from normal operation to severe accident events, and high-speed simulation on parallel processing computers. The integral plant behaviors of typical PWR and BWR under severe accident conditions have been analyzed with the IMPACT-SAMPSON code. The PWR plant analyzed was the three-loop, steel-dry containment type with 2,440 MWt. The AE accident scenario was supposed, that is, LOCA by 6-inch hot leg failure followed by accumulated water injection, but no ECCS and containment spray activation. The BWR plant analyzed was the 3,293 MWt BWR-5, Mark-II containment type. ...
2003-07-01
Energy Technology Data Exchange (ETDEWEB)
Development was explained of non-phosphate detergent with zeolite (Z) and alpha-olefin sulfonate (AOS). 4A type Z was taken notice of as a builder to replace phosphate. In calcium ion trapping power, conventional sodium tripolyphosphate (STP) and Z are 158mgCaO/g and 150mg/g, respectively. However, because Z by the conventional method is large in crystal diameter, coagulates and adheres to matter to be washed, was newly developed fine Z, 0.9 {mu} m in primary grain diameter, which does not give abrasion nor occlusion to the washing machine, nor precipitate in the river. Because linear alkylbenzene sulfonate, combined with Z, is poorer in washing power than that, done with STP, was developed AOS, new non-phoshate use interfacial active detergent, which is excellent in all washing power, biodegradation speed and physical powder property. Improvement was variously made also in powdery detergent production technology. Though ...
1990-07-01
International Nuclear Information System (INIS)
Ozone formation by a pulse positive corona discharge generated in the gas phase between a planar high voltage electrode made from reticulated vitreous carbon and a water surface with an immersed ground stainless steel plate electrode was investigated under various operating conditions. The effects of gas flow rate (0.5-3 litre min"-"1), discharge gap spacing (2.5-10 mm), applied input power (2-45 W) and gas composition (oxygen containing argon or nitrogen) on ozone production were determined. Ozone concentration increased with increasing power input and with increasing discharge gap. The production of ozone was significantly affected by the presence of water vapour formed through vaporization of water at the gas-liquid interface by the action of the gas phase discharge. The highest energy efficiency for ozone production was obtained using high voltage pulses of approximately 150 ns ...
2005-02-07
Generalized simulation model for reservoir system analysis. Technical paper
Energy Technology Data Exchange (ETDEWEB)
This paper overviews the general features of computer program 'HEC-5, Simulation of Flood Control and Conservation Systems', with emphasis on the capabilities of the most recent release of HEC-5, Version 7.2, dated March 1991. HEC-5 can simulate the essential features and operation goals and constraints of simple or complex systems with simulation intervals ranging from minutes to one month. Single event flood analysis and period of record conservation analysis may be accomplished with the model. Flood control analysis includes balanced system operation for downstream damage centers with consideration of forecasted local flows and hydrologic routing. In addition, induced surcharge operation based on spillway gate regulation schedules can be simulated. Hydropower analysis may include run-of-river, peaking, and pumped storage plants as well as system power operation. Water supply simulation can include reservoir and downstream ...
1992-03-01
Recovery of Water from Boiler Flue Gas
Energy Technology Data Exchange (ETDEWEB)
This project dealt with use of condensing heat exchangers to recover water vapor from flue gas at coal-fired power plants. Pilot-scale heat transfer tests were performed to determine the relationship between flue gas moisture concentration, heat exchanger design and operating conditions, and water vapor condensation rate. The tests also determined the extent to which the condensation processes for water and acid vapors in flue gas can be made to occur separately in different heat transfer sections. The results showed flue gas water vapor condensed in the low temperature region of the heat exchanger system, with water capture efficiencies depending strongly on flue gas moisture content, cooling water inlet temperature, heat exchanger design and flue gas and cooling water flow rates. Sulfuric acid vapor condensed in both ...
2008-09-30
Energy Technology Data Exchange (ETDEWEB)
Petropavlovsk-Kamchatky (P-K) city in Kamchatka, Russia is operating hot-water district heating using heavy oil boilers and waste hot water of thermal power plants as heat sources. Feasibility study was made on district heating using natural geothermal hot water and/or geothermal heat pump systems as heat sources of hot water supply for reduction of greenhouse effect gas emission. Among 3 areas including geothermal hot water, use of hot water in K area was impossible because of lower temperature and less spring water. Use of hot water in P and UP areas was impossible as primary hot water because of temperature drop to 64 degrees C during hot water supply toward P-K city. The building heating operation test was carried out using the geothermal heat pump system ...
1999-05-01
Neon-20 depth-dose relations in water
Energy Technology Data Exchange (ETDEWEB)
The dose from heavy ion beams has been calculated using a one-dimensional transport theory and evaluated for 670 MeV/amu /sup 20/Ne beams in water. The result is presented so as to be applicable to arbitrary ions for which the necessary interaction data are known. The present evaluation is based on the Silberberg-Tsao fragmentation parameters augmented with light fragment production from intranuclear cascades, recently calculated nuclear absorption cross sections, and evaluated stopping power data. Comparison with recent experimental data obtained at the Lawrence Berkeley Laboratory reveals the need for more accurate fragmentation data.
1984-05-01
Loss of flow accident analysis of a water-cooled fusion reactor
International Nuclear Information System (INIS)
Within the APROS simulation environment we have built a thermo-hydraulic model of a conceptual fusion power plant which is water cooled and uses lithium-lead for tritium breeding. For the safety assessment of this design we have studied an accident sequence which starts from a loss or coolant flow then leads to first wall breach and pressurisation of the vacuum vessel. Simulations have revealed strong pressure transients which can be alleviated by design changes. One goal is to verify the adequacy of the containment design: it remains intact at least 14 h without any mitigating efforts. Estimates for radioactive releases are obtained. (author)
2003-08-25
Energy Technology Data Exchange (ETDEWEB)
A cooling system for rejecting waste heat consists of a cooling tower incorporating a plurality of coolant tubes provided with cooling fins and each having a plurality of cooling channels therein, means for directing a heat exchange fluid from the power plant through less than the total number of cooling channels to cool the heat exchange fluid under normal ambient temperature conditions, means for directing water through the remaining cooling channels whenever the ambient temperature rises above the temperature at which dry cooling of the heat exchange fluid is sufficient and means for cooling the water. 5 figs.
1980-01-22
Formation and decay of secondary actinides in water reactor and fast neutron reactors
International Nuclear Information System (INIS)
Actinides other than the main uranium or plutonium isotopes take a growing part in the different stages of the nuclear cycle. For the French nuclear power program based on the development of light water reactors and fast breeders, many evaluations of the secondary actinides build up are made for the both reactor types using mainly the existing reactor codes. The comparison of these foreseen compositions with experimental results allows to perform some adjustments of the neutronic data. The secondary actinide compositions are given for some typical fuels and their consequences on the nuclear cycle are discussed. An hypothetical burning of these wastes in fast reactors has been studied and the main conclusions are reported.
Effect of secondary circuit materials and water regime on steam generator reliability
International Nuclear Information System (INIS)
The mechanism of the salt concentration increase in pits and crevices formed in a steam generator due to its imperfect manufacture or to its design features is described. The probability of corrosion can be reduced by choosing a suitable steel and by securing low concentrations of salts (chlorides in particular) and corrosion products in the feedwater. Attention is paid to the distribution of salts in the water-steam circuit and to the conditions of erosion corrosion as the principal source of corrosion products in feedwater. Experience with the suppression of erosion corrosion at nuclear power plants abroad is described. (E.J.).
1989-05-01
International Nuclear Information System (INIS)
Unit one of Daya Bay, China's first nuclear power plant was officially opened in February 1994. The nuclear island has been built by Framatome and is an improved version of the Gravelines 5 and 6, 900MWe Pressurized Water Reactors. Extra seismic protection has been included because of greater earthquake risk. The heat exchanger capacity has also been increased as the sea cooling water can be at 30"oC. The technical specifications and details of the fuel loading are given. The technical assistance, management and training of Chinese personnel are discussed. Two further units may be built if Daya Bay 1 is successful. (UK).
International Nuclear Information System (INIS)
Problem areas in BWRs, PWRs and PHWRs, from the viewpoint of chemistry, and the problem of fission product release in nuclear reactors are discussed. These problem areas are : fuel performance, off-normal water chemistry due to condenser leaks, the transport and deposition of the activated corrosion and fission products, denting in steam generators (in the case of PWRs), ingress of air in the cover gas helium and consequent radiolysis of D_2O in the moderator circuit (in the case of PHWRs). (M.G.B.).
1981-05-01
A parametric analysis of decay ratio calculations in a boiling water reactor model
Energy Technology Data Exchange (ETDEWEB)
The results of an investigation of the effects of several parameters on the reactivity instability of a Boiling Water Reactor (BWR) calculational model are summarized. Calculations were performed for a typical BWR operated at low flow conditions, where reactivity instabilities are more likely to occur. The parameters investigated include the axial power shape (characterized by two separate parameters), the core pressure, and operating flow. All calculations were performed using the LAPUR code which was developed at the Oak Ridge National Laboratory for the dynamic modeling of large BWR's. 4 refs., 8 figs.
1989-01-01
Steam generator tube performance: experience with water-cooled nuclear power reactors during 1979
International Nuclear Information System (INIS)
The performance of steam generator tubes in water-cooled nuclear power reactors has been reviewed for 1979. Tube failures occurred at 38 of the 93 reactors surveyed. Causes of these failures and procedures designed to deal with them are described. The defect rate was twice that in 1978 but still lower than the two previous years. Methods being employed to detect defects include increasing use of multifrequency eddy-current testing and a trend to full-length inspection of all tubes. To reduce the incidence of tube failures by corrosion, plant operators are turning to full-flow condensate demineralization and more leak-resistant condenser tubes. (author).
1994-10-18
Energy Technology Data Exchange (ETDEWEB)
This is a process for producing calcium sulfate dihydrate during desulfurization of stack gases from power station boilers, where the stack gases are introduced into a washing tower and are treated with a washing water suspension containing lime in the washing tower, where oxygen in the form of air or of air enriched in oxygen is also blown into the washing tower, and where the washing water suspension drawn off from the washing tower is fed back to the washing tower at a temperature of 45 to 50/sup 0/C in the circuit and at least part of the flow goes via a thickener and where calcium sulfate dihydrate slurry is drawn off from the thickener.
1986-06-12
International Nuclear Information System (INIS)
Tata Electric Companies (TEC) are engaged in the generation of hydro and thermal energy. TEC, to minimise backing down of its thermal units in off peak hours and also to at least partially meet the growing deficit in the supply during peak hours is moving to install pumped storage plants (PSPs) utilising off-peak surplus energy for pumping the water from lower pond to the upper pond for subsequent utilisation for power generation during peak hours. In view of some of the infra structural facilities such as storage ponds, water conductor system, transmission lines, etc. being already available, at the existing hydro power stations owned by TEC, the pumped storage units are being proposed within the environs of existing hydro stations, i.e. a 150 MW pumped storage unit at Bhira and a 90 MW pumped storage unit at Bhivpuri. The projects are described and cost estimates is given. (author). 2 figs.
1992-01-01
Energy Technology Data Exchange (ETDEWEB)
Excitation of low temperature helium or helium/water plasma and subsequent exposure to air of polyacrylonitrile (PAN) ultrafiltration membranes was used to hydrophilize the surface of these materials. We analyzed the effectiveness of this approach as a function of plasma operating variables including gas phase composition, plasma power, treatment time and system pressure. Following the changes in physical and chemical composition of the PAN surface resulting from these modifications was a major aspect of this work. Techniques such as the captive bubble contact angle method, ellipsometry, ESCA, and FTIR-ATR were all used. In addition, the formation and life-time of peroxides during these processes were determined. At low powers (<25W) and short treatment periods ({<=}30 sec), the main chemical conversion of PAN surfaces was simultaneous hydrophilization and stabilization via PAN cyclization. Relatively small ...
1995-12-01
Validation of flux mapping system (FMS) of TAPP-4 with TRIVENI
International Nuclear Information System (INIS)
The reactor core of TAPP-3 and 4 is divided into 14 power zones for spatial power control. Corresponding to each zone is a light water zonal compartment. The 14 ZCCs are located in two radial planes, each containing 7 ZCCs. For each zone, power measurement is carried out using three cobalt Self Powered Neutron Detectors (SPNDs) at appropriate locations close to the respective ZCC. Since the zone power as obtained by the true average of the healthy zone control detector (ZCD) readings belonging to a particular zone may not correspond to its actual power because these 3 detectors per zone, measure only point fluxes but the zone extends over a large core region. Therefore accurate estimation of zone power calibration factors is required to estimate the zone powers and also to provide effective spatial ...
2006-11-13
International Nuclear Information System (INIS)
A typical form of change in runoff characteristics caused by the widespread use of hydroelectric power in Switzerland is the intermittent draining (torrent operation). It is the aim of the present work to help elucidate possible consequences of these changes in drain onto the benthobiocoenosis. The study was carried through on the Secklisbach at Oberrickenbach (in the semicanton of Nidwalden) and one of its side streamlets (800m above sea level). The macroinvertebrate coenosis was studied at four locations with similar conditions of drainage basin, population density and topography but varying in the degree of impairment to the draining. There were monthly benthos samples taken using a Surber sampling-device. Results show that the locations not only varied in drain, but also in temperature, this being a consequence of water storage by the power plant. The readings pointed out different values for the locations in daily ...
International Nuclear Information System (INIS)
The author gives the historical development of steam-turbine construction in Europe since the turn of the century, and the technical further development of conventional turbines due to the increases in the steam parameters and per-unit outputs in the increases in the steam parameters and per-unit outputs in Europe and the USA. Marginal conditions for the development of turbines in nuclear power stations with light-water reactors are mentioned. The rise in the per-unit capacities of the turbosets constructed in Germany and the USA for nuclear power stations is discussed. Longitudinal sections through typical turbines are shown. The future development of turbines with high output is dealt with. (orig.).
On the threshold of the 21st Century in the Soviet Union
International Nuclear Information System (INIS)
In the last 30 years the production of electricity in the USSR has increased 14-fold, probably attaining 1540 billion kWH in 1985. Nuclear generation will provide the bulk of future increases of consumption, using both water-cooled and uranium/graphite reactors; stations of up to 1.5 million kW are in service. The USSR is also in the fore-front of attempts to exploit thermonuclear power. The USSR is also conducting experiments with renewable sources of energy such as solar, geothermal, wind and wave power and with magnetohydrodynamic generation. (D.A.J.).
International Nuclear Information System (INIS)
A non-linear mathematical model of dynamics of horizontal steam generator for nuclear power unit with WWER type reactor is presented. To realize this model the GEMMA-120 simulation language for computer Odra-1204 has been used. Necessity of taking into account disposited thermal storage capacities along tubulation of a primary cycle is demonstrated. A number of lumped elements of reactor division against a required static accuracy of calculations has been determined. (author).
1977-01-01
International Water Power and Dam Construction Handbook 1993
Energy Technology Data Exchange (ETDEWEB)
In this handbook, technical reports on a number of hydro plants under construction are provided. In addition tables of compiled data are presented on a world-wide basis for the following: turbine and hydro generator contracts; hydropower resource potential and development; pumped storage plants; the major dams and hydro plants; roller compacted concrete dams and concrete faced rockfill dams; small hydropower. An address database of international organizations of relevance to hydropower development, national power authorities and nation committees of the International Commission an Large Dams is included. A final and major section of the handbook is a buyer's guide providing extensive company data and information on products and services. (UK)
1993-01-01
International Nuclear Information System (INIS)
This paper introduces the inter-comparison results of some environmental radioactivity monitoring items for Daya Bay nuclear power plant. The inter-comparison was organized by China Institute for Radiation Protection and five laboratories participated in it. The compared items included total #beta# in kelp and sediment, "3H in water, "9"0Sr in soil, artificial nuclides "1"1"0"mAg, "2"4"1Am, "1"0"9Cd, "5"7Co in kelp and sediment. Inter-comparison results are analyzed as well
2003-01-01
Development of safety function assessment trees for pressurized heavy water reactor LP/SD operations
Energy Technology Data Exchange (ETDEWEB)
The objective of Configuration Risk Management Program(CRMP) is to maintain the safety level by assuring the defense-in-depth of nuclear power plant while the configurations are changed during plant operations, especially for the LP/SD. Such a safety purpose can be achieved by establishing the risk monitoring programs with both quantitative and qualitative features. Generally, the quantitative risk evaluation models, i.e., PRA models are used for the risk evaluation during full power operation, and the qualitative risk evaluation models such as safety function assessment trees are used. Through this study, safety function assessment trees were developed.
2003-10-01
Conservation of power station components during standstill by means of dry air
International Nuclear Information System (INIS)
The use of pre-dehumidified air having widely established itself as a safe and economical conservation method during the stoppage of steam turbines, it was obvious that this method would be applied also to steam boilers and ancillary aggregates. Experience with the conservation of condensers, prheaters and the water/steam-side of steam boilers in large-scale power stations is reported on. By the example of projects with topical interest, the problems and possibilities of boiler conservation on the firing side are illustrated. The contribution is to stimulate further discussions. (orig.).
Back-up for high voltage cable pressurizing system
Energy Technology Data Exchange (ETDEWEB)
A back-up system is provided for a pumping plant or a pressure reservoir system used to maintain insulating oil under pressure in high voltage submarine power cables which includes a gas driven membrane pump to insure a small outflow of oil at a rupture point in the power cable to prevent water from penetrating the cable. The proper operation of the membrane pump is insured by introducing degasified oil at the drive side of the pump during the stand-by and test modes of operation of the back-up system. 11 drawings.
1982-07-19
Energy Technology Data Exchange (ETDEWEB)
Emerging high-power microwave technologies require that bioeffects of exposure to this type of radiation be investigated for health and safety considerations. Disruption of animal behavior is reported to be a sensitive indicator of microwave exposure. Three behavioral tasks were chosen for this initial investigation of exposure to U.S. Air Force high-power microwave emitters. The tasks were: (1) single-trail avoidance, (2) water satiation, and (3) rotarod performance. Exposure to high-power microwave radiation from the USAFSAM peak-power simulator significantly affected the single-trail avoidance task. Neither the single-trail avoidance task nor rotarod performance was affected by the Gypsy emitter. However, animals exposed to 9-kW and 11-kW outputs from the USAFSAM emitter spent significantly less time imbibing water postexposure than sham-exposed animals. The ...
1988-02-01
Status report on the fusion breeder
Energy Technology Data Exchange (ETDEWEB)
The rationale for hybrid fusion-fission reactors is the production of fissile fuel for fission reactors. A new class of reactor, the fission-suppressed hybrid promises unusually good safety features as well as the ability to support 25 light-water reactors of the same nuclear power rating, or even more high-conversion-ratio reactors such as the heavy-water type. One 4000-MW nuclear hybrid can produce 7200 kg of /sup 233/U per year. To obtain good economics, injector efficiency times plasma gain (eta/sub i/Q) should be greater than 2, the wall load should be greater than 1 MW m/sup -2/, and the hybrid should cost less than 6 times the cost of a light-water reactor. Introduction rates for the fission-suppressed hybrid are unusually rapid.
1980-12-12
Energy Technology Data Exchange (ETDEWEB)
The ability of the /sup 252/Cf-source-driven neutron noise analysis method to measure subcriticality has been demonstrated in a variety of experimental configurations of fissile materials. Calculations for an approximately 4-m-dia configuration of light water reactor (LWR) fuel elements indicated the feasibility of measuring the subcriticality of large, loosely coupled arrays of LWR fuel elements by this same method. These analysis suggested application to the initial loading of both pressurized and boiling water reactors, zero-power testing of reactors (such as shutdown margin measurements after initial loading), light water reactor refueling, and safe storage of LWR spent fuel. In the fuel storage application, direct measurement of subcriticality in the actual fuel storage facilities provides the parameter which is directly related to criticality safety.
1984-01-01
Influence of two systematic parameters on the geothermal heat pump system operation
Energy Technology Data Exchange (ETDEWEB)
In order to match the output capacity of a geothermal heat pump system (GHPS) with the actual load requirement, research has been carried out in finding the influence of two systematic parameters, the water flow rate inside the condenser and the compressor input frequency on the GHPS operation. Experiments are done on a small-scale GHPS at the water flow rate ranging from 0.054 kg/s to 0.174 kg/s and the frequency from 30 Hz to 55 Hz. The analysis of the experimental data reveals the relationships among the compressor frequency, the water flow rate and other important parameters such as coefficient of performance (COP), heat capacity and compressor power input. The conclusions in the paper can serve as some guidance to the load adjustment of GHPS. (author)
2003-01-01
International Nuclear Information System (INIS)
Imatran Voima Oy , (IVO) operates two Russian designed nuclear power plants of type VVER440/213. Unit 1 has been operating since 1977 and unit 2 since 1981. First damage of feed water distribution (FWD) pipes was observed in 1989. In closer examinations FWD-pipe T-connection and distribution nozzles suffered from severe erosion corrosion damage. Similar damages have been found also in other VVER-440 type NPPs. In 1994 the first FWD-pipe was replaced by a new design mounted over the tube bundle instead of the old FWD-pipe, which was located inside the tube bundle. The purpose of this paper is to describe the new FWD-pipe and discuss its effects on the steam generator chemistry. (author)
1998-06-01
Energy Technology Data Exchange (ETDEWEB)
Contamination and blockages of the cooling tubes in the turbine condenser disturb the heat transfer, thereby causing power losses at the turbine and increasing the fuel demand. Corrosions cause tubing leakages which require operating downtimes and reduce the lifetime of the pipes. Tube cleaning systems and backflushing cooling water filters eliminate these problems. Nevertheless it can come to coatings in the condenser tubes, if the tube cleaning equipment does not operate optimally or if coarse dirt is entered. Under this aspect, the author of the contribution under consideration reports on these problems on the basis of practical examples. The author gives references to the optimized operation of the tube cleaning system and the cooling water filtration.
2010-07-01
Energy Technology Data Exchange (ETDEWEB)
The performance of the Magma Power Company's reinjection well No. 46-7 at East Mesa has been examined. Water was cooled to 100/sup 0/F(+-) to simulate total heat extraction and then tested using membrane filter flow procedures. The cooled water contains particles which are in the high colloid size range, and formation impairment by these particles is unlikely. There is evidence that acid soluble corrosion products and calcium compounds constitute about two thirds of the particulates, and that the acid insoluble residue contains precipitated silica, insoluble corrosion products, and possibly formation fines carried in the produced water. Under stabilized conditions, the suspended solids content of the water is less than 2 parts per million. However, during the frequent production well start ups, a higher concentration of suspended solids is carried in the produced ...
1980-02-01
International Nuclear Information System (INIS)
PWR plants have made efforts to maintain the long-term integrity of the steam generators (SG) by reducing the amount of corrosion products entering the secondary side of the SG. Iron entered the SG can cause several problems: degraded heat conductivity of the SG tubes in locations where iron is deposited, water level oscillations in the SG due to tube support plate hole blockage, and initiation and propagation of inter-granular attacks (IGA) and stress corrosion cracking (SCC). One of the most effective measures, high all-volatile treatment (AVT) chemistry has been applied to actual plants to reduce the flow-accelerated corrosion (FAC) coming from the carbon steel piping. The secondary water chemistry at Genkai NPS 1 and 2 changed, from the Low AVT chemistry to the High AVT chemistry, in November 2006. In this paper, we will describe the results of experiments in applying the use of High pH water in the secondary ...
2009-02-01
Influence of fly ash on soil physical properties and turfgrass establishment
Energy Technology Data Exchange (ETDEWEB)
A field study (1993-96) assessed the benefits of applying unusually high rates of coal fly ash from power plants as a soil amendment to enhance water retention of soils without adversely affecting growth and marketability of the turf species, centipedegrass (Eremochloa ophiuroides (Munro) Hack.) A Latin Square plot design was employed that included 0 (control, no fly ash applied), 280, 560 and 1120 MgHa {sup -1} application rates of unweathered precipitator fly ash. The fly ash was spread evenly over each plot area, rototilled, and allowed to weather under natural conditions for 8 months before seeding. High levels of soluble salts, indicated by the electrical conductivity of soil extracts, in tandem with an apparent phytotoxic effect from boron, apparently inhibited initial plant establishment as shown by substantially lower germination counts in treated soil. However, plant height and rooting depth were not adversely affected, as were the dry ...
2001-04-01
Direct solar water splitting cell using water, WO3, Pt, and polymer electrolyte membrane
British Library Electronic Table of Contents (United Kingdom)
A solar water splitting cell composed of WO3, Polymer Electrolyte Membrane (PEM) and Pt was constructed for producing hydrogen from deionized water in sunlight. Spectral responsivity measurements under various temperatures and bias voltages were conducted for the cell using the Incident Photon to Current Efficiency (IPCE) method. For comparison, a known WO3 Photo Electro Chemical (PEC) cell containing H3PO4 electrolyte, WO3/H3PO4/Pt, was tested using the same test method. The WO3/PEM-H2O/Pt cell showed better Quantum Efficiency (QE) performance compared to that obtained from the cell with the chemical electrolyte. For the first time, spectral responsivity of photo water splitting process without bias power was unveiled in the new WO3 cell, demonstrating the self-sustained photo electrolysi...
2009-01-01
Drinking water composition and incidence of urinary calculus: introducing a new index.
INTRODUCTION. We searched for a pathophysiologically based feature of major water electrolytes, which may define water quality better than the water hardness, respecting urinary calculus formation. MATERIALS AND METHODS. Utilizing a multistage stratified sampling, 2310 patients were diagnosed in the imaging centers of the provincial capitals in Iran between 2007 and 2008. These were composed of 1755 patients who were settled residents of 24 provincial capitals. Data on the regional drinking water composition, obtained from an accredited registry, and their relationships with the region's incidence of urinary calculi were evaluated by metaregression models. The stone risk index (defined as the ratio of calcium to magnesium-bicarbonate product in drinking water) was used to assess the risk of calculus formation. RESULTS. No correlation was found between the urinary calculus incidence ...
2011-01-01
Advanced applications of water cooled nuclear power plants
International Nuclear Information System (INIS)
By August 2007, there were 438 nuclear power plants (NPPs) in operation worldwide, with a total capacity of 371.7 GW(e). Further, 31 units, totaling 24.1 GW(e), were under construction. During 2006 nuclear power produced 2659.7 billion kWh of electricity, which was 15.2% of the world's total. The vast majority of these plants use water-cooled reactors. Based on information provided by its Member States, the IAEA projects that nuclear power will grow significantly, producing between 2760 and 2810 billion kWh annually by 2010, between 3120 and 3840 billion kWh annually by 2020, and between 3325 and 5040 billion kWh annually by 2030. There are several reasons for these rising expectations for nuclear power: - Nuclear power's lengthening experience and good performance: The industry now has more than 12 000 reactor years of experience, and the global average nuclear ...
2007-07-01
Advanced applications of water cooled nuclear power plants
International Nuclear Information System (INIS)
By August 2007, there were 438 nuclear power plants (NPPs) in operation worldwide, with a total capacity of 371.7 GW(e). Further, 31 units, totaling 24.1 GW(e), were under construction. During 2006 nuclear power produced 2659.7 billion kWh of electricity, which was 15.2% of the world's total. The vast majority of these plants use water-cooled reactors. Based on information provided by its Member States, the IAEA projects that nuclear power will grow significantly, producing between 2760 and 2810 billion kWh annually by 2010, between 3120 and 3840 billion kWh annually by 2020, and between 3325 and 5040 billion kWh annually by 2030. There are several reasons for these rising expectations for nuclear power: - Nuclear power's lengthening experience and good performance: The industry now has more than 12 000 reactor years of experience, and the global average nuclear ...
1996-07-21
Advanced applications of water cooled nuclear power plants
International Nuclear Information System (INIS)
By August 2007, there were 438 nuclear power plants (NPPs) in operation worldwide, with a total capacity of 371.7 GW(e). Further, 31 units, totaling 24.1 GW(e), were under construction. During 2006 nuclear power produced 2659.7 billion kWh of electricity, which was 15.2% of the world's total. The vast majority of these plants use water-cooled reactors. Based on information provided by its Member States, the IAEA projects that nuclear power will grow significantly, producing between 2760 and 2810 billion kWh annually by 2010, between 3120 and 3840 billion kWh annually by 2020, and between 3325 and 5040 billion kWh annually by 2030. There are several reasons for these rising expectations for nuclear power: - Nuclear power's lengthening experience and good performance: The industry now has more than 12 000 reactor years of experience, and the global average nuclear ...
2007-11-23
Design and operating experience of a 40 MW, highly-stabilized power supply
Energy Technology Data Exchange (ETDEWEB)
Four 10 MW, highly-stabilized power supply modules have been installed at the National High Magnetic Field Laboratory in Tallahassee, FL, to energize water-cooled, resistive, high-field research magnets. The power supply modules achieve a long term current stability if 10 ppM over a 12 h period with a short term ripple and noise variation of <10 ppM over a time period of one cycle. The power supply modules can operate independently, feeding four separate magnets, or two, three or four modules can operate in parallel. Each power supply module consists of a 12.5 kV vacuum circuit breaker, two three-winding, step-down transformers, a 24-pulse rectifier with interphase reactors, and a passive and an active filter. Two different transformer tap settings allow rated dc supply output voltages of 400 and 500 V. The rated current of a supply module is 17 kA and each supply module has a ...
1995-07-01
Energy Technology Data Exchange (ETDEWEB)
We find dosage of gamma emitters radionuclides of samples collected in the environment of the Chinon nuclear power plant for 2002 and 2003, these results are presented in two tables: concentrations in gamma emitter radionuclides of samples collected in the terrestrial environment (soils) and aquatic environment (sediments) of the site of Chinon in june 2002 in the frame of the annual surveillance, the second table concerns the concentrations in gamma emitter radionuclides of samples collected in the terrestrial environment (soils and lichens) of the site of Chinon in may 2003 in the frame of the annual surveillance. We find also the dosage of free tritium in the water of the Loire river for 2002 and 2003, upstream and downstream to the power plant of Chinon. (N.C.)
2003-07-01
Status of the surry low power and shutdown PRA
International Nuclear Information System (INIS)
The Surry low power and shutdown probabilistic risk analysis (PRA) is an ongoing project at Brookhaven National Laboratory (BNL) to identify and quantify potential accident scenarios that may occur in a pressurized water reactor (PWR) during low power and shutdown. It was initiated as a result of various incidents and accidents that have occurred within the United States and overseas. The project involves review and evaluation of PWR experience at shutdown, identification of accident scenarios, determination of methods to mitigate the accidents, and performance a level 1 PRA. An evaluation of accident progression, source terms and consequences has also been initiated. The results will be used to address issues related to shutdown conditions. The objective of this paper is to provide a progress report on the project, and to present the approach used as well as the preliminary results of the ongoing and completed tasks.
1991-04-01
Private power in the country -- a chronology
Energy Technology Data Exchange (ETDEWEB)
The chronology of installing solar power in a rural area of Ontario is described. The installation took all of seven years, and was characterized by a lot of joy, but also a lot of heartache and hardship, all of which are chronicled in this article. The project started with four solar modules generating 300 watts, nickel cadmium batteries of 225 Ah, an inverter of 600 watt, and a three-cylinder 6.5 Kw water-cooled propane generator. Today, nearly seven years later, the installation consists of 18 solar modules supplying 1350 watts of power, lead-acid batteries of 2770 Ah, a 2500 watt inverter, a one cylinder, 5.5 kw propane-gasoline generator, a heated, underground generator house, complete with an amp-hour meter and MPPT charge controller.
2003-06-30
Preliminary assessment of the modular block power plant concept
Energy Technology Data Exchange (ETDEWEB)
Adding capacity to coal-fired plants in small increments of an overall integrated program may be the solution to the 10-year lead time required for the construction of a new plant. A preliminary study evaluates the technical and economic feasibility of a modular natural gas and coal-fired combined-cycle power plant which can be installed in three distinct phases. The plant sizes are suitable for large industrial and utility applications. The Modular Block Power Plant (MBPP) concept offers the advantages of phase construction, lower capital cost, lower cost electricity, lower air emissions, lower water requirements, and reduced solid waste discharge. Other advantages include part load availability, reduced coal inventory requirements, and easier plant siting. 11 figures, 4 tables.
1984-01-01
Benefit analysis and evaluation of pumped-storage plant in Taipower system
Energy Technology Data Exchange (ETDEWEB)
The operation of pumped-storage plants (PSP) is based on the daily load variations of power demand. It performs power generation at peak load times during the day, and pumps water up into the reservoir during the off-peak times at night. In the Taipower system in Taiwan, there are two pumped storage plants with ten units. These had a total installed capacity of 2,602 MW or a 12 percent capacity at the end of 1995. The plants were able to reduce system generation costs and improve reliability. A Pumped-Storage Plant Benefit Analysis (PSPBA) program was established using the principle of economic dispatch in 1985. This paper explains the rules of the program, the analysis results of the past 10 years, and a a cost benefit evaluation. It was found that the advantages of PSP are not only in supplying the power for peak load, but also in decreasing the total fuel cost. 5 figs., 4 refs.
1995-12-31
Energy Technology Data Exchange (ETDEWEB)
Several technological alternatives have been studied taking into consideration that one of the biggest problems of the electric power companies is to provide electric power during the peak consumption periods, which largest contribution to the increase of the demand comes from the residential sector, especially by the use of electric showers. One of the most promising alternatives is the pre-water heating system for reduced power showers, developed by Universidade de Campinas and Companhia Paulista de Forca e Luz. The goal of this system is basically to reduce demand during the peak periods, in order to avoid heavy investments by the electric power companies in generation, transmission and distribution of electric power directed to low acquisitive power customers, a sector in which the electric power price is not enough ...
1996-12-31
Thermal-hydraulic characteristic of the PGV-1000 steam generator
International Nuclear Information System (INIS)
Horizontal steam generators are typical parts of nuclear power plants with pressure water reactor type VVER. By means of this computer program, a detailed thermal-hydraulic study of the horizontal steam generator PGV-1000 has been carried out and a special attention has been paid to the thermal-hydraulics of the secondary side. A set of important steam generator characteristics has been obtained and analyzed. Some of the interesting results of the analysis are presented in the paper. (author)
1995-09-11
International Nuclear Information System (INIS)
On the 3. and 4. November 1982 the sixth conference of the Corporation for Reactor Safety (GRS) was held in Cologne's Guerzenich. The theme of this year's meeting was the 'Status of Risk Investigations at Nuclear Power Plants'. A principal topic was a report on findings made by the GRS during the 'Risk Oriented Analysis SNR-300'. The second topic comprised the newest developments within Phase B of the Risk Study of Water Pressure Reactors, the discussion of the dose/effect relationship and considerations on threshold risk values. (orig.).
Temperature coefficient in D_2O moderated reactor (Wolsung Unit 1)
International Nuclear Information System (INIS)
The temperature coefficient has been investigated on the Wolsung nuclear power reactor, in which fuel is natural uranium dioxide and moderator heavy water. The numerical computations are carried out in terms of changes of the effective neutron multiplication factor with respect to fuel, moderator, and coolant temperatures. Those results are compared with the computed values of temperature coefficient based on the LATREP computer code. (author).
1977-01-01
Steam generator design improvements for the candu wolsung nuclear power plant
International Nuclear Information System (INIS)
Design considerations are given for the secondary side region of a vertical U-tube nuclear stream generator with an integral preheater. The thermal shield design, the novel recirculating water flow distribution scheme, the high porosity tube supports used in the parallel flow regions, and the U-bend supports are discussed for the Wolsung Plant steam generators. Experimental and analytical development programs undertaken to verify the design features are outlined.
1978-01-01
New technologies in fossil-fuel utilization
Energy Technology Data Exchange (ETDEWEB)
This document contains the outline and viewgraphs used in the speech. Topics covered are: conventional oil and gas recovery; unconventional oil and gas sources; oil shale resources; conventional coal combustion; advanced fossil power systems; fluidized bed combustion; coal/oil or coal/water mixtures; and gaseous and liquid fuels from coal. (DMC)
1982-01-01
Incident report: spillage of reactor coolant at Wolsung
International Nuclear Information System (INIS)
Late last year the Wolsung Candu in Korea suffered an incident which resulted in heavy water being released from the primary system into the containment. With the unit now back at full power, this article examines the causes of the incident and the action which is being taken to prevent it happening again. (author).
1985-01-01
In-plane resolved in-situ measurements of the membrane resistance in PEFCs
Energy Technology Data Exchange (ETDEWEB)
The conductivity of the membrane is a limiting factor for the efficiency and power density of PEFCs. Because this conductivity is strongly dependent on the membrane hydration, water management is an important aspect of PEFC optimisation. Single cell model experiments were made in order to determine the in-plane hydration of a Nafion{sup R} membrane under fuel cell conditions as function of the gas humidities. (author) 4 fig., 3 refs.
1999-08-01
Efficiency of preliminary transmutation of actinides before ultimate storage
International Nuclear Information System (INIS)
The concept of preliminary transmutation of minor actinides before placement to the long-term storage is considered. The purpose of such preliminary transmutation before ultimate storage is to incinerate a part of actinides and to transform another part into new actinides providing low level of radiotoxicity accumulated in the storage. Modes of transmutation in reactors of PWR, PHWR (CANDU), and Superfenix types are compared. Among power reactors, heavy-water PHWR type reactor is most acceptable for preliminary transmutation. (author)
2003-04-20
Dual fuel engine solves the solvent problem
Energy Technology Data Exchange (ETDEWEB)
Some 200 visitors attended the official opening of a new diesel engine driven cogeneration plant in the city of Hamburg at the end of March. The dual fuel engine built by Blohm+Voss will supply 7.7 MW of electricity to the grid and 8.26 MW of thermal power to generate steam and hot water. (author)
1993-05-01
Condenser replacement at Unterweser nuclear power station
International Nuclear Information System (INIS)
In spite of extensive cooling water studies premature damage due to corrosion occurred on the CuZn20Al condenser tubes. It was then decided to incorporate new titanium-tubed condensers during the annual overhauls of 1983 and 1985 and also take ameliorating measures up to the exchange of individual condensers. (orig.).
...Chapter 11 Aqueous Solutions Chapter 11 Aqueous Solutions Download the entire chapter (PDF-136k) Drilling to China More water than rivers Saving the aquifer Drying with Xeriscapes Everywhere in the house Rainwater and graywater Creating urban watersheds Wastewater equals ...3851 Powered by Intrcomm Technology's SMC ...
Capturing sun for car and house; Fanger sol til bil og hus
Energy Technology Data Exchange (ETDEWEB)
Solar panels have been installed at the roof, providing enough power to drive electric cars 20 000 kilometres yearly, while water-borne heating in the household has reduces electricity demand by 12-13 000 kWh per year
2008-07-01
Status of the advanced boiling water reactor and simplified boiling water reactor
International Nuclear Information System (INIS)
This paper reports that the excess of U.S. electrical generating capacity which has existed for the past 15 years is coming to an end as we enter the 1990s. Environmental and energy security issues associated with fossil fuels are kindling renewed interest in the nuclear option. The importance of these issues are underscored by the National Energy Strategy (NES) which calls for actions which are designed to ensure that the nuclear power option is available to utilities. Utilities, utility associations, and nuclear suppliers, under the leadership of the Nuclear Power Oversight Committee (NPOC), have jointly developed a 14 point strategic plan aimed at establishing a predictable regulatory environment, standardized and pre-licensed Advanced Light Water Reactor (ALWR) nuclear plants, resolving the long-term waste management issue, and other enabling conditions. GE is participating in this national effort and GE's family of ...
1992-04-13
Energy Technology Data Exchange (ETDEWEB)
Based on the IAPWS technical guidance on ''Instrumentation for Monitoring and Control of Cycle Chemistry for Steam-Water Circuits of Fossil-Fired and Combined Cycle Power Plants,'' the latest situation regarding instrumentation for nuclear power plants is discussed. As a result of the discussion, it is concluded that: (1) Reliable and safe operation of plants is established by the application of suitable chemical conditions in plant cooling systems, which should be supported by the selection of suitable control targets for monitoring and by the application of reliable instruments. (2) The minimum level of key instrumentation consists of on-line as well as off-line instruments for monitoring the key parameters: - on-line: pH, conductivity, cation conductivity, O{sub 2} and H{sub 2} concentrations, electrochemical corrosion potential; - off-line: radioactive nuclides ({sup 60}Co, {sup ...
2010-05-15
An evaluation of the ecological consequences of partial-power operation of the K Reactor, SRS
International Nuclear Information System (INIS)
The K Reactor at the Savannah River Site (SRS) shut-down in spring 1988 for maintenance and safety upgrades. Since that time the receiving stream for thermal effluent, Indian Grave Branch and Pen Branch, have undergone a pattern of post-thermal recovery that is typical of other SRS streams following removal of thermal stress. Divesity of fish and aquatic macroinvertebrate communities has increased and available habitats have been colonized by numerous species of herbaceous and woody plants. K Reactor is scheduled to resume operation in 1991 and operate through 1992 without a cooling tower to cool the discharge. It is likely that the reactor will operate at approximately one-third to one-half of full power (800--1200 MW thermal) during this period and effluent temperatures will be substantially lower than earlier operation at full power. Monthly average discharge temperatures at half-power operation will range from ...
The coil of the MBI bending magnets for the LHC injection transfer lines
All MBI bending magnets in each of the two LHC injection transfer lines will be powered in series. The limited output voltage of existing power converters lead to an unusual coil design avoiding external return bus-bars by combining two overlapping half-coils, electrically separated, with 3 1/2 turns each in a monolithic structure. The voltage between turns in one coil can reach up-to 3.6 kV. The coil has been designed with particular care for obtaining high interturn and ground insulation. Flux-free soldering of connections with plug-in cone sleeves is applied, allowing to execute water cooled current connections as prolongation of the coil conductor. Epoxy compound polymerization in the impregnation mould is obtained by passing overheated water in regulated cycles through the water circuit of the coil conductor. We describe the design basics as well as various test results of ...
2002-01-01
Macrofouling control in nuclear power plants
International Nuclear Information System (INIS)
Macrofouling of cooling-water systems is one of the more significant and costly problems encountered in the nuclear power industry. Both marine and freshwater macroinvertebrates can be responsible for losses in plant availability because of plugged intakes and heat transfer equipment. There is a greater diversity of macrofouling organisms in marine waters than in fresh waters. Marine macrofouling organisms include barnacles, mollusks, bryozoans, and hydroids. Barnacles are crustaceans with feathery appendages, which allow them to attach to a variety of surfaces. They are a major cause of severe macrofouling because they can remain attached even after death. The major freshwater macrofouling organisms include the Asiatic Clam (Corbicula fluminea) and the newest freshwater macrofouler, the Zebra Mussel (Dreissena polymorpha). The introduction of the Zebra Mussel into the Great Lakes has created economic ...
1991-11-10
Long-term corrosion study at nuclear power plant Bohunice (Slovakia)
International Nuclear Information System (INIS)
Steam generators of four VVER-440 units at nuclear power plants V-1 and V-2 in Jaslovske Bohunice (Slovakia) were gradually changed by new original 'Bohunice' design in period 1994-1998. Corrosion processes before and after these design and material changes in Bohunice secondary circuit were studied using Moessbauer spectroscopy during last 25 years. Innovations in the feed water pipeline design as well as material composition improvements were evaluated positively. Moessbauer spectroscopy studies of phase composition of corrosion products were performed on real specimens scrapped from water pipelines or in form of filter deposits. The corrosion of new feed water pipelines system (from austenitic steel) in combination to innovated operation regimes goes dominantly to magnetite. The hematite presence is mostly on the internal surface of steam generator body and its concentration increases towards the top ...
2010-03-01
Liquid zone system events at Wolsong Unit 2
International Nuclear Information System (INIS)
On June 19, 1998, after the first annual outage, Wolsung Unit 2 was shutdown at a controlled rate due to the continuous instability of Liquid Zone Control level. Investigation revealed that the Liquid Zone Control level instability was caused by water condensed inside the helium lines, generated from the moistened helium flow, especially, inside the helium balance header feed and bleed valve lines. It was found that improper installation of the diaphragm type isolation valves and the drain valve tap could easily contain the water inside the lines and be destined to form water traps causing the balance header pressure oscillation. After the lines were dried, Liquid Zone Control level instability was almost vanished, and approached the allowable equilibrium state. As the reactor power was increased, however, the zone level instability increased again. In order to compensate for the excessive, the Bulk ...
1998-09-07
Data Center Energy Benchmarking: Part 3 - Case Study on an ITEquipment-testing Center (No. 20)
Energy Technology Data Exchange (ETDEWEB)
The data center in this study had a total floor area of 3,024 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 147 racks, and was located in a 96,000 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but was served by the main building chiller plant and make-up air system. Additionally it was served by only a single electrical supply with no provision for backup power in the event of a power outage. The Data Center operated on a 24 hour per day, year-round cycle, and users had full-hour access to the data center facility. The study found that data center computer load accounted for 15% of the overall building electrical load, while the total power consumption attributable to the data center ...
2007-07-01
Stationary low power reactor No. 1 (SL-1) accident site decontamination & dismantlement project
The Army Reactor Area (ARA) II was constructed in the late 1950s as a test site for the Stationary Low Power Reactor No. 1 (SL-1). The SL-1 was a prototype power and heat source developed for use at remote military bases using a direct cycle, boiling water, natural circulation reactor designed to operate at a thermal power of 3,000 kW. The ARA II compound encompassed 3 acres and was comprised of (a) the SL-1 Reactor Building, (b) eight support facilities, (c) 50,000-gallon raw water storage tank, (d) electrical substation, (e) aboveground 1,400-gallon heating oil tank, (f) underground 1,000-gallon hazardous waste storage tank, and (g) belowground power, sewer, and water systems. The reactor building was a cylindrical, aboveground facility, 39 ft in diameter and 48 ft high. The lower portion of the building contained the reactor pressure ...
1995-11-01
Power-cycle studies for a geothermal electric plant for MX operating bases
Energy Technology Data Exchange (ETDEWEB)
Binary geothermal plants were investigated for providing electrical power for MX missile bases. A number of pure hydrocarbons and hydrocarbon mixtures were evaluated as working fluids for geothermal resource temperatures of 365, 400, and 450/sup 0/F. Cycle thermodynamic analyses were conducted for pure geothermal plants and for two types of coal-geothermal hybrid plants. Cycle performance results were presented as net geofluid effectiveness (net plant output in watts per geofluid flow in 1 bm/hr) and cooling water makeup effectiveness (net plant output in watts per makeup water flow in 1 bm/hr). A working fluid containing 90% (mass) isobutane/10% hexane was selected, and plant statepoints and energy balances were determined for 20MW(e) geothermal plants at each of the three resource temperatures. Working fluid heaters and condensers were sized for these plants. It is concluded that for the advanced plants investigated, ...
1981-11-01
International Nuclear Information System (INIS)
The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For detector position out side the RB containment, ...
2005-11-23
Nuclear desalination for the petrochemical complex of the Natuna project
International Nuclear Information System (INIS)
On the basis of environmental considerations, a high temperature gas cooled reactor (HTGR) was proposed as the heat source for the Natuna project for CO_2 conversion. To convert CO_2 to useful products, a large amount of high quality water is required for the chemical processes, boilers and other purposes. One LNG production train (maximum of six trains) would produce 0.4 x 10"9 SCF/d of saleable gas and 1.4 x 10"9 SCF/d of CO_2 (in the case of the Exxon process). This CO_2 gas would then be converted to automobile fuel (methane, methanol), which requires a large amount of water. Natural gas from an off- shore gas field is piped to the petrochemical complex on Natuna Island (about 228 km). Natuna is a small island that, apart from sea water, does not have much available water. The desalination process is considered to be the only solution to the water demand problems of the ...
1997-12-01
Energy Technology Data Exchange (ETDEWEB)
In France, groundwater usage represents 40 per cent of volumetric use, outside of thermal power plants. Groundwater represents 60 per cent of domestic and public use, 40 per cent in the industrial sector, and is increasing in the agricultural sector where it accounts for 20 per cent. Groundwater withdrawal in France has slightly increased over the last twenty years and benefited the agricultural sector. Availability throughout the territory, the consistency of resupply and natural quality has rendered groundwater a prevailing source for drinking water. Water protection and management is important and led to the adoption of legislative and regulatory measures. The Mining Code (Code minier) allows for exploitation of underground resources starting at 10 metres. The Rural Code (Code rural) mandates the declaration of public utility for water collection for the public. Protection areas are to be provided ...
2001-07-01
Providing online access to historic films at the Washington State University libraries
British Library Electronic Table of Contents (United Kingdom)
Purpose - This paper aims to discuss the procedures and methods developed at Washington State University to digitize and make accessible historic moving images. Design/methodology/approach - The paper describes the selection and the use of low-cost technologies to transfer analog film to digital formats. Issues related to the conversion, description, and online hosting of digital films are also addressed. Findings - Though the steps involved in digitizing film are not trivial, the benefits of access both for the public and archives staff outweigh the expense and labor involved. The procedures described in this paper involve low upfront costs and are sustained through cost recovery fees. Research limitations/implications - The focus of this paper is on managing, describing, and providing on...
2011-01-01
Recent historical changes on the Belgian Meuse
International Nuclear Information System (INIS)
When a nuclear power station was installed on the Meuse in central Belgium, the impact of thermal, radioactive, and chemical waste on the water of the Neuse and on its biocenoses was studied. Three successive periods of development of the channel bed and the flood plain in Belgium have occurred, and their hydrological, physicochemical, and ecological consequences have been examined. Since the last century, the ecosystem of the Meuse has undergone, due to the increasing activity of man, modifications of increasing importance: marked reduction of the water flow, a drastic increase in the suspended material being transported, a degree of eutrophication of the water, and the disturbance of the original floral and faunal communities. The causes of this evolution of the Meuse can be itemized as different types of human interference in descending order of importance: (1) occupation of the catchment area; (2) ...
Proceedings: Water treeing and aging
Energy Technology Data Exchange (ETDEWEB)
This report presents the record of the workshop Water Treeing and Aging.'' The workshop was held in Phoenix, Arizona on December 9--11, 1990 and was sponsored by the Distribution Program of the Electrical Systems Division of the Electric Power Research Institute (EPRI). Attendance at the workshop was by invitation only. Twenty two attendees from seven countries, from universities, research organizations, electric utilities and polymeric materials suppliers took part in this workshop. The workshop was designed to assess progress in the understanding of water treeing phenomena and polymeric cable insulation aging since the last meeting of a similar forum of experts, which was organized by the Office of Exploratory Research of EPRI in December 1985. The objective of the present workshop was to assess progress and to provide direction for further studies in this field. The discussions covered a wide range of ...
1991-10-01
Preliminary study of the effect of pumped-storage plant operation on zooplankton
Energy Technology Data Exchange (ETDEWEB)
The hydromechanical effect of hydroelectric stations on zooplankton is customarily regarded as a constantly acting and comparatively harmless factor, since its destruction is inevitable when water masses are passed through hydroelectric stations, but its capacity for restoration is high (i.e., destruction of the zooplankton of the forebay is compensated by its production in the after bay). It is not known how correct such an opinion is, or what is the true balance of losses and reproduction of zooplankton in the forebays and after bays of hydroelectric stations. However, hydroelectric plants of a new type, pumped-storage plants, have been constructed in recent years and others are planned for the Dnieper reservoirs. The operational principle and purpose of these plants is that they employ special vertical turbine-electric pumps that pump water at night from the reservoirs into pumped-storage facilities at high levels, and then release this ...
1980-01-01
Diesel engine experiments with oxygen enrichment, water addition and lower-grade fuel
Energy Technology Data Exchange (ETDEWEB)
The concept of oxygen enriched air applied to reciprocating engines is getting renewed attention in the context of the progress made in the enrichment methods and the tougher emissions regulations imposed on diesel and gasoline engines. An experimental project was completed in which a direct injection diesel engine was tested with intake oxygen levels of 21% -- 35%. Since an earlier study indicated that it is necessary to use a cheaper fuel to make the concept economically attractive, a less refined fuel was included in the test series. Since a major objection to the use of oxygen enriched combustion air had been the increase in NO{sub x} emissions, a method must be found to reduce NO{sub x}. Introduction of water into the engine combustion process was included in the tests for this purpose. Fuel emulsification with water was the means used here even though other methods could also be used. The teat data indicated a large increase in engine ...
1990-01-01
Development and field application of a leak sealant for the NRU water reflector
International Nuclear Information System (INIS)
The development and successful application of a unique leak sealant formulation comprised of a mixture of graded, hollow ceramic microspheres, surface oxidized aluminum powder and saturated gibbsite suspension is described. The project was undertaken to address the escalating leakage from up to 15 small weld defects in the water reflector vessel, an integral component of the NRU (National Research Universal) reactor calandria. The reflector surrounds the reactor core with a neutron reflecting blanket of light water. Injection of the sealant is typically done with the reactor shutdown and the water reflector system operating normally, but can also be performed with the reactor at full power. The procedure is simple and effective. Individual treatments of as little as 125 ml of sealant (10 ppm in the 12,500 L system) have yielded leak reductions exceeding 2000 L/day. The accumulated leak reductions of ...
2001-06-10
Energy Technology Data Exchange (ETDEWEB)
Chlorine is widely used in drinking water disinfection due to be a powerful and not expense disinfection. Although the benefits of disinfection, the formation of stable disinfection by-products of the health concern, is the result of the interaction of aqueous chlorine with natural organic matter presents in water. Disinfection by-products generated in major concentration are trihalomethane and haloacetic acids. Disinfection by-products generated in minor concentration are haloacetonitriles, haloketones,chloral hydrate and chloropicrin and some new groups such as cyanogen halides and trihaloacetaldydes. In this work two analytical methods.: headspace/gas chromatography/electron capture detector and liquid-liquid microextraction/gas chromatography/electron capture detector are studied and compared to determine the minor by-products and to establish finally, a systematic control of them in the different stages of the ...
1997-09-01
Guide to Combined Heat and Power Systems for Boiler Owners and Operators
Energy Technology Data Exchange (ETDEWEB)
Combined heat and power (CHP) or cogeneration is the sequential production of two forms of useful energy from a single fuel source. In most CHP applications, chemical energy in fuel is converted to both mechanical and thermal energy. The mechanical energy is generally used to generate electricity, while the thermal energy or heat is used to produce steam, hot water, or hot air. Depending on the application, CHP is referred to by various names including Building Cooling, Heating, and Power (BCHP); Cooling, Heating, and Power for Buildings (CHPB); Combined Cooling, Heating, and Power (CCHP); Integrated Energy Systems (IES), or Distributed Energy Resources (DER). The principal technical advantage of a CHP system is its ability to extract more useful energy from fuel compared to traditional energy systems such as conventional power plants that only generate ...
2004-08-19
Energy Technology Data Exchange (ETDEWEB)
A study was made for the purpose of electrification of unelectrified zones of the mountainous areas in developing countries using extremely small hydroelectric power facilities. The target for this project is a development of a micro hydroelectric power system with a size of about 5kW, which is estimated regarding that 1 village has 80 houses and each house needs electricity of 60W. In the study, the low-head system using a weir of irrigation channels in Subang pref. of West Java state was selected by the evaluation of access, stability of flow rate, natural conditions, etc. The hydroelectric power plant is of a flow-in method in which water is taken from the left bank and is injected/discharged to the downstream of the left bank. As the hybrid complementary power source, hybrid battery with a two-hour charging time at peak and a capacity of 3.5kWh was considered. When estimating ...
1996-03-01
Data Center Energy Benchmarking: Part 4 - Case Study on aComputer-testing Center (No. 21)
Energy Technology Data Exchange (ETDEWEB)
The data center in this study had a total floor area of 8,580 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 440 racks, and was located in a 208,240 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but served by the main building chiller plant and make-up air system. Additionally, it was served by a single electrical supply with no provision for backup power. The data center operated on a 24 hour per day, year-round cycle, and users had all hour full access to the data center facility. The study found that data center computer load accounted for 23% of the overall building electrical load, while the total power consumption attributable to the data center including allocated cooling load and lighting was 30% of the ...
2007-08-01
Internal dose from tritium at Wolsung nuclear power plant
International Nuclear Information System (INIS)
Tritium is produced in large quantities at heavy water nuclear power reactors via the neutron activation reaction "2H(n,#gamma#)"3H. At Wolsung nuclear power plant which has a CANDU reactor, the tritium concentrations in coolant and in moderator systems are 1.5 Ci/Kg-D_2O and 35 Ci/kg-D_2O, respectively, after 12 years of operation. The airborne tritium concentration in main access area is normally less than 5 MPCa except short-term peaks. The average tritium concentrations in main access controlled areas are normally less than 100 MPCa. Tritium is mainly present in the air of workplace of CANDU reactors as a tritiated water vapour. Airborne tritiated water vapour enters the workers body via inhalation and absorption through skin and can result in a significant dose. The occupational doses from tritium at Wolsung NPP have been maintained below 1 man-Sv per year so far. The tritium ...
1995-02-01
Energy Technology Data Exchange (ETDEWEB)
A guidance document on the instrumentation for monitoring and control of cycle chemistry for the steam-water circuits of fossil-fired and combined-cycle power plants was developed within the IAPWS Power Cycle Chemistry Working Group. This technical guidance document has been authorized by the International Association for the Properties of Water and Steam (IAPWS) at its meeting in Doorwerth, The Netherlands, 6-11 September, 2009, for issue by its Secretariat. The members of the IAPWS are: Britain and Ireland, Canada, the Czech Republic, Denmark, France, Germany, Greece, Japan, Russia, and the United States of America, and the associate members Argentina and Brazil, Italy, and Switzerland. In order to achieve suitable chemical conditions in steam-water circuits it is essential to establish reliable monitoring of key parameters on every plant. This enables the demonstration of ...
2009-10-15
Energy Technology Data Exchange (ETDEWEB)
Water power plants mean the design, configuration, execution and operation of buildings and of hydraulic and electrical machines. Their many types are due to the stages of development and the technical alternatives of the use of waterpower and the associated energy economy aspects. The main points of this work are the use of water power, different hydro-electric powerstations, water collection, machines and electrotechnical equipment. In the 2nd revised edition parts on electrical engineering, environment, minimum water run-off pumped storage plants, small scole plants, economical aspects and finite elements were broadened. It is a comprehensive textbook and technical book for students of civil engineering and particularly suitable for engineers active in the theory and practice of waterpower construction. (orig./GL) [Deutsch] Wasserkraftanlagen bedeuten ...
1998-12-01
Energy Technology Data Exchange (ETDEWEB)
Water power plants mean the design, configuration, execution and operation of buildings and of hydraulic and electrical machines. Their many types are due to the stages of development and the technical alternatives of the use of waterpower and the associated energy economy aspects. The main points of this work are the use of water power, different hydro-electric powerstations, water collection, machines and electrotechnical equipment. In the 2nd revised edition parts on electrical engineering, environment, minimum water run-off pumped storage plants, small scole plants, economical aspects and finite elements were broadened. It is a comprehensive textbook and technical book for students of civil engineering and particularly suitable for engineers active in the theory and practice of waterpower construction. (orig./GL) [German] Dieses Standardwerk der Wasserkraft ...
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
The primary coolant oxidises the surfaces of construction materials in nuclear power plants. The properties of the oxide films influence significantly the extent of incorporation of actuated corrosion products into the primary circuit surfaces, which may cause additional occupational doses for the maintenance personnel. The physical and chemical properties of the oxide films play also an important role in different forms of corrosion observed in power plants. This report gives a short overview of the factors influencing activity build-up and corrosion phenomena in nuclear power plants. Furthermore, the most recent modifications in the water chemistry to decrease these risks are discussed. A special focus is put on zinc water chemistry, and a preliminary discussion on the mechanism via which zinc influences activity build-up is presented. Even though the exact mechanisms by which ...
1999-03-01
Evaluation of critical heat flux of tight lattice core with subchannel analysis code NASCA
International Nuclear Information System (INIS)
Reduced-Moderation Water reactor (RMWR) is a light water breeder reactor developed by Japan Atomic Energy Research Institute (JAERI). The RMWR comprises tight lattice fuel assemblies with gap clearance of around 1.0 mm to reduce water volume ratio to achieve a high conversion ratio. It is important to estimate the thermal hydraulic safety margin of the tight lattice core of the RMWR. In the present study, the boiling transition (BT) prediction performance of the subchannel analysis code NASCA developed for the current BWR cores was assessed for series of tight lattice critical heat flux (CHF) experiments performed in JAERI. The test section was a 7-rod bundle with rod diameter of 12.3 mm, rod gap of 1.0 mm and heated length of 1.8m. Axial power distribution was flat. With a simple subchannel model, the code overestimates the critical power in the high mass velocity region, although ...
2003-04-20
International Nuclear Information System (INIS)
The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 (16N) and Oxygen-19 (19O) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of 19O and 16N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high ambient radiation level even though sensitivity is appreciably good. For detector position in RB in the accessible ...
2006-11-13
International Nuclear Information System (INIS)
In the summer of 1990, an accidental spill from the TA-3 Power Plant Environment Tank released more than 3,785 liters of sulfuric acid into upper Sandia Canyon. The Biological Resource Evaluation Team (BRET) of EM-8 at Los Alamos National Laboratory (LANL) has collected aquatic samples from the stream within Sandia Canyon since then. These field studies gather water quality measurements and collect macroinvertebrates from permanent sampling sites. An earlier report by Bennett (1994) discusses previous BRET aquatic studies in Sandia Canyon. This report updates and expands Bennett's initial findings. During 1993, BRET collected water quality data and aquatic macroinvertebrates at five permanent stations within the canyon. The substrates of the upper three stations are largely sands and silts while the substrates of the two lower stations are largely rock and cobbles. The two upstream stations are located near outfalls that ...
2004-06-01
An overview of AECL's participation in the Korean Wolsung Tritium Removal Facility Project (WTRF)
International Nuclear Information System (INIS)
Full text: In heavy-water-moderated power reactors, tritium is primarily produced by neutron capture in deuterium nuclei in the moderator and coolant. For CANDU 6 reactors, the estimated steady-state values are #approx# 3 TBq#centre dot#kg"-"1 D_2O in the moderator and #approx# 74 GBq#centre dot#kg"-"1 D_2O in the coolant. Tritium removal is one option available to reactor operators for use in their heavy water and tritium management strategies. The WTRF is designed to remove tritium from tritiated heavy water in each of the four CANDU units at the Wolsung Site, to immobilize the tritium and to store it on site. The detritiation process is based on three steps: the first one (front-end) involves the transfer of tritium from heavy water to deuterium gas; the second one (enrichment) concentrates the tritium in a cryogenic distillation system to produce essentially pure D_2 and T_2 ...
2007-11-07
Verification of coolant flow distribution in 540 MWe Indian PHWR during commissioning
International Nuclear Information System (INIS)
The pressurized Heavy Water Reactor (PHWR) consists of horizontal calandria vessel containing a large number of pressure tubes (fuel channels) connected to the reactor inlet and outlet headers by individual feeders. Coolant flow distribution among the pressure tubes play a vital role in extraction of thermal power. For these reactors one of the design objectives is to achieve uniform coolant outlet temperatures by providing coolant flows according to the channel power. This is achieved by the design process known as feeder sizing. This basically consists of accounting for the individual channel power and centre line geometry of individual feeder and iteratively adjusting the feeder hydraulic resistances within the design constraints such as limiting flow velocities, channel flows. Recently, the first unit of 540 MWe i.e Tarapur Atomic Power Project (unit 4) has been commissioned. ...
2006-11-13
International Nuclear Information System (INIS)
At Tarapur Atomic Power Station 3 and 4, 540 MWe Pressurised Heavy Water Reactors, core being large in size requires a continuous in core monitoring for local flux disturbances. Nearly 200 Self Powered Neutron Detectors (SPNDs) of the Straight Individually Replaceable (SIR) type are distributed in the reactor core. For purpose of reactor regulation and protection, cobalt SPNDs that have a prompt response for changes in power is used for in-core flux mapping, vanadium SPNDs that provide accurate measure of neutron flux, even though having slow response is used In core SPNDs are placed in Vertical Flux Units (VFU) and Horizontal Flux Units (HFUs). These SPNDs were to be replaced at regular intervals to meet the design intent. Cobalt SPNDs have dose rates of the order of 1000 Gy/h and the Mineral Insulated (MI) cables of Vanadium SPNDs have dose rates of the order of 100 Gy/h. So far 3 Cobalt SPNDs were ...
2006-11-13
Energy Technology Data Exchange (ETDEWEB)
The paper is concerned with the economic operation of power systems comprising pumped storage and thermal plants. In power systems, pumped storage plants may receive the energy required for pumping water either from the system in which they are integrated or from a neighbouring system. Therefore, two mathematical formulations of the problem are presented depending on the source of energy during pumping. In both cases, the problem is reduced to a non linear optimization problem. Two numerical techniques are suggested for the solution of this optimization problem, namely the Lagrangian Multipliers technique and the Rosen Gradient Projection technique. Numerical examples are presented to demonstrate the techniques. Although the Lagrangian Multipliers technique has the advantage of being a well known technique, however, computer wise, the Rosen Gradient Projection technique proves to be more efficient. The results of the ...
1980-12-01
Modeling of a horizontal steam generator for the submerged nuclear power station concept
Energy Technology Data Exchange (ETDEWEB)
A submerged nuclear power station has been proposed as an alternative power station with a relatively low environmental impact for use by both industrialized and developing countries. The station would be placed 10 m above the seabed at a depth of 30--100 m and a distance of 10--30 km from shore. The submerged nuclear power station would be manufactured and refueled in a central facility, thus gaining the economies of factoryfabrication and the flexibility of short-lead-time deployment. To minimize the size of the submerged hull, horizontal steam generators are proposed for the primary-to-secondary heat transfer, instead of the more traditional vertical steam generators. The horizontal steam generators for SNPS would be similar in design to the horizontal steam generators used in the N-Reactors except the tube orientation is horizontal (the tube's inlet and outlet connection points on the tubesheet are at the same ...
1993-01-01
Modeling of a horizontal steam generator for the submerged nuclear power station concept
Energy Technology Data Exchange (ETDEWEB)
A submerged nuclear power station has been proposed as an alternative power station with a relatively low environmental impact for use by both industrialized and developing countries. The station would be placed 10 m above the seabed at a depth of 30--100 m and a distance of 10--30 km from shore. The submerged nuclear power station would be manufactured and refueled in a central facility, thus gaining the economies of factoryfabrication and the flexibility of short-lead-time deployment. To minimize the size of the submerged hull, horizontal steam generators are proposed for the primary-to-secondary heat transfer, instead of the more traditional vertical steam generators. The horizontal steam generators for SNPS would be similar in design to the horizontal steam generators used in the N-Reactors except the tube orientation is horizontal (the tube`s inlet and outlet connection points on the tubesheet are at the same ...
1993-05-01
Modeling of a horizontal steam generator for the submerged nuclear power station concept
International Nuclear Information System (INIS)
A submerged nuclear power station has been proposed as an alternative power station with a relatively low environmental impact for use by both industrialized and developing countries. The station would be placed 10 m above the seabed at a depth of 30--100 m and a distance of 10--30 km from shore. The submerged nuclear power station would be manufactured and refueled in a central facility, thus gaining the economies of factoryfabrication and the flexibility of short-lead-time deployment. To minimize the size of the submerged hull, horizontal steam generators are proposed for the primary-to-secondary heat transfer, instead of the more traditional vertical steam generators. The horizontal steam generators for SNPS would be similar in design to the horizontal steam generators used in the N-Reactors except the tube orientation is horizontal (the tube's inlet and outlet connection points on the tubesheet are at the same ...
1993-07-06
Measures for reliability improvement of on-site power plant at steel works
Energy Technology Data Exchange (ETDEWEB)
This report describes the arrangement and features of the Ogishima thermal power plant facilities, as well as activities being performed there for operation control, regular inspection and improvement in reliability. The power plant uses about 48 percent of the by-product gas as its fuel to supply about 81 percent of the required power. Operation of the No. 1 unit started in 1976. Currently, the plant has three units, each with an output of 125MW. Each unit consists of a natural circulation boiler with a maximum evaporation capacity of 410 ton/hour and a reheat regenerative condensing turbine with a main vapor pressure of 127 kg/cm/sup 2/G. Techniques used for water properties control and combustion control are also described. In the plant, convetional time management integrity techniques are now being replaced by state management integrity techniques that determines the deterioration tendency in ...
1988-04-15
Materials needs for compact fusion reactors
Energy Technology Data Exchange (ETDEWEB)
The economic prospects for magnetic fusion energy can be dramatically improved if for the same total power output the fusion neutron first-wall (FW) loading and the system power density can be increased by factors of 3 to 5 and 10 to 30, respectively. A number of compact fusion reactor embodiments have been proposed, all of which would operate with increased FW loadings, would use thin (0.5 to 0.6 m) blankets, and would confine quasi-steady-state plasma with resistive, water-cooled copper or aluminum coils. Increased system power density (5 to 15 MWt/m/sup 3/ versus 0.3 to 0.5 MW/m/sup 3/), considerably reduced physical size of the fusion power core (FPC), and appreciably reduced economic leverage exerted by the FPC and associated physics result. The unique materials requirements anticipated for these compact reactors are outlined against the well documented backdrop provided by ...
1983-01-01
International Nuclear Information System (INIS)
Over the past few years, NPCIL has performed comprehensive Level-1 Probabilistic Safety Assessment (PSA) for a 220 MWe Pressurised Heavy Water Reactor (PHWR) at Kakrapar Atomic Power Station (KAPS) and for the first 540 MWe PHWR at Tarapur Atomic Power Project (TAPP- 3 and 4). The major objective of these PSAs was to present an integrated picture of the safety of the plant to identify and understand key plant vulnerabilities. As a result of the availability of these PSAs, there is a desire to use them to operate the plants in the most efficient manner practicable. In recent years, the operation of Indian Nuclear Power Plants has been characterized by improved availability/capacity factors and reduced forced outages. Frequency of planned outages is also being reduced. In order to achieve this, the PSAs are now being used as an engineering tool for optimization of Technical Specifications with regard to ...
2005-12-01
BWNT assessment of TRAC/PF1-MOD2
International Nuclear Information System (INIS)
The TRAC/PFI-MOD2 Version 5.3 code was assessed against six FLECHT-SEASET forced reflood tests (31504, 31203, 31302, 31701, 34209, and 31922) and two cylindrical core test facility (CCTF) tests [C1-19 and C2-6]. The objective of this study was to evaluate the clad thermal response predictive capabilities of the code with the newly added reflood model under large-break loss-of-coolant accident (LOCA) conditions in a pressurized water reactor (PWR). The TRAC model for the FLECHT-SEASET test facility was developed from a RELAP5 model. The test section was modeled using a vessel component with 23 axial levels, 1 radial ring, and 1 azimuthal cell. Test inlet and exit conditions were modeled using fill and break components, respectively. The measured lower and upper plenum test conditions were input to the model. The electrically heated rod was modeled using a rod component with 22 axial mesh points. The axial boundary of each mesh point coincided with a fluid cell ...
1993-11-14
Water Quality and 401 Certification | Clean Water Act | US EPA
Clean Water Act You are here: Water Laws & Regulations Policy & Guidance Clean Water Act Water Quality and 401 Certification Water Quality and 401 Certification Water Quality...
2011-08-28
The PANDA facility and first test results
International Nuclear Information System (INIS)
The PANDA test facility at the Paul Scherrer Institute is used to study the long-term performance of the Simplified Boiling Water Reactor's passive containment cooling system. The PANDA tests demonstrate performance on a larger scale than previous tests and examine the effects of any non-uniform spatial distributions of steam and non-condensable gases in the system. The facility is in 1:1 vertical scale and 1:25 scale for volume, power etc. Extensive facility characterization tests and steady-state passive containment condenser performance tests are presented. The results of the base case test of a series of transient system behaviour tests are reviewed. The first PANDA tests exhibited reproducibility, and indicated that the Simplified Boiling Water Reactor's containment is likely to be favorably responsive and highly robust to changes in the thermal transport patterns. (orig.).
International Nuclear Information System (INIS)
Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by Deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on Tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-3 and 4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)
2006-11-13
International Nuclear Information System (INIS)
Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)
2005-11-23
Special features of control and protection for large saturated steam turbines
International Nuclear Information System (INIS)
For shut-down safety of the turbine generator (securing of auxiliary power operation after load shut-down and preventing the reaching of overspeed after load shut-down with disturbed turbine governing system) additional measures compared to those for superheated steam turbines are required for turbine generators in plants with pressurized water reactor (PWR) as well as those with boiling water reactor (BWR) . Equipment is described (e.g. overspeed govern or selecting connection, vacuum breaker, bypass valves, intercepting valves) which, depending on the own conditions of the individual turbine generator (e.g. run-up time, vacuum, enclosed energy), may be applied alone or in jointly. (orig.).
Radiological operating experience at FFTF [Fast Flux Test Facility
International Nuclear Information System (INIS)
The Fast Flux Test Facility has been in operation for approximately five years, including about one thousand days of full power operation of the Fast Test Reactor. During that time the collective dose equivalents received by operating personnel have been about two orders of magnitude lower than those typically received at commercial light water reactors. No major contamination problems have been encountered in operating and maintaining the plant, and release of radioactive gas to the environment has been minimal and well below acceptable limits. All shields have performed satisfactorily. Experience to date indicates an apparent radiological superiority of liquid metal reactor systems over current light water plants.
1987-04-22
International Nuclear Information System (INIS)
Ppercase(femaxi-iv) is a computer code for the analysis of thermal and mechanical behavior of light water reactor fuel rods during steady-state and transient conditions. The main purpose of ppercase(femaxi-iv) is to calculate the stress and strain distributions in the fuel and cladding due to the pellet-cladding mechanical interaction, and the fission gas release rate during operations, especially power transients. The capability of ppercase(femaxi-iv) was extensively tested with a number of experimental results obtained in some international fuel irradiation programs. This paper provides a general description of the various models involved in ppercase(femaxi-iv) and some results of applications on the experimental data. ((orig.)).
1994-01-01
New technology for purging the steam generators of nuclear power plants
British Library Electronic Table of Contents (United Kingdom)
A technology for removal of undissolved impurities from a horizontal steam generator using purge water is developed on the basis of a theoretical analysis. A purge with a maximal flow rate is drawn off from the zone with the highest accumulation of sludge in the lower part of the steam generator after the main circulation pump of the corresponding loop is shut off and the temperatures of the heat transfer medium at the inlet and outlet of the steam generator have equilibrated. An improved purge configuration is used for this technology; it employs shutoff and regulator valves, periodic purge lines separated by a cutoff fixture, and a D y 100 drain union as a connector for the periodic purge. Field tests show that the efficiency of this technology for sludge removal by purge water is severa...
2011-01-01
High concentration low wattage solar arrays and their applications
Energy Technology Data Exchange (ETDEWEB)
Midway Labs currently produces a 335x concentrator module that has reached as high as 19{percent} active area efficiency in production. The current production module uses the single crystal silicon back contact SunPower cell. The National Renewable Energy Lab has developed a multi junction cell using GalnP/GaAs technologies. The high efficiency ({gt}30{percent}) and high cell voltage offer an opportunity for Midway Labs to develop a tracking concentrator module that will provide 24 volts in the 140 to 160 watt range. This voltage and wattage range is applicable to a range of small scale water pumping applications that make up the bulk of water pumping solar panel sales. {copyright} {ital 1997 American Institute of Physics.}
1997-02-01
Gas turbine tops 40% efficiency; features novel inlet-air cooler
Energy Technology Data Exchange (ETDEWEB)
This article reports on the world's first gas turbine to top 40% thermal efficiency in simple cycle and is now operating commercially as part of a natural-gas-fired combined-cycle cogeneration (CC) plant serving the Ottawa Health Sciences Center, Ottawa, Ont, Canada. Owned and operated by TransAlta Energy Corp, Calgary, Alta, the CC plant supplies steam and hot and chilled water to the health center and another thermal user while the electricity is sold to Ontario Hydro. Part of the project included the conversion of 15-psig steam-carrying equipment to hot-water service. Commercial success of this installation heralds a new era in the application of efficient gas turbines for power generation.
1993-02-01
GRI's Gas Appliance Technology Center Activities at Battelle. Final report, 1986-1992
The Gas Research Institute established the Gas Appliance Technology Center (GATC) in 1982 to develop improved gas appliances. Between 1986 and 1992, the scope of GATC activities at Battelle included technology transfer and overall industry support, residential appliances, commercial appliances, and residential space conditioning. The following tasks are representative of the GATC activities described in the report; gas burner technology, appliance venting, emissions, water heating, range/oven technology, self-powered appliances, commercial cooktop burners, reconstituting ovens, appliance reliability improvement, combination space-heating/water-heating systems, condensing heat exchangers, corrosion testing, and space heating technology. The report includes references to available sources for further reading.
1993-08-01
An assessment study of the sea water scrubbing process for flue gas desulfurization has been made by SINTEF. This project has been financially supported by the Royal Ministry of Environment of Norway. The study is based on three FGD-units which are installed at three oil-fired, industrial boilers respectively with a maximum continuous heat input of 130 MW (27 MW + 2x51.5 MW) corresponding to approximately 50 MWE (10 MWE + 2x20 MWE) generating capacity for a power plant having a net efficiency of 38%.
1979-01-01
Energy Technology Data Exchange (ETDEWEB)
Femaxi-iv is a computer code for the analysis of thermal and mechanical behavior of light water reactor fuel rods during steady-state and transient conditions. The main purpose of femaxi-iv is to calculate the stress and strain distributions in the fuel and cladding due to the pellet-cladding mechanical interaction, and the fission gas release rate during operations, especially power transients. The capability of femaxi-iv was extensively tested with a number of experimental results obtained in some international fuel irradiation programs. This paper provides a general description of the various models involved in femaxi-iv and some results of applications on the experimental data. ((orig.))
1994-06-01
Extraction of Cs-137 by alcohol-water solvents from plants containing cardiac glycosides
As a result of nuclear power plant accidents, large areas receive radioactive inputs of Cs-137. This cesium accumulates in herbs growing in such territories. The problem is whether the herbs contaminated by radiocesium may be used as a raw material for medicine. The answer depends on the amount of Cs-137 transfered from the contaminated raw material to the medicine. We have presented new results of the transfer of Cs-137 from contaminated Digitalis grandiflora Mill. and Convallaria majalis L. to medicine. We found that the extraction of Cs-137 depends strongly on the hydrophilicity of the solvent. For example 96.5%(vol.) ethyl alcohol extracts less Cs-137 (11.6%) than 40%(vol.) ethyl alcohol or pure water (66.2%). The solubility of the cardiac glycosides is inverse to the solubility of cesium, which may be of use in the technological processes for manufacturing ecologically pure herbal medicine.
2001-01-01
A comparison between steam injection cycle and combined cycle by energy balance
International Nuclear Information System (INIS)
This paper reports on steam injection cycle which is similar to supplementary fired combined cycle, but for the utilized steam medium produced by HRSG, its temperature is higher and pressure is lower than in the combined cycle. In comparison with the thermodynamic advantage of the two cycles, a clear understanding of physical concept can be gotten simply by energy balance. The difference of total power output between them is subtraction of enthalpy difference of exhaust steam and feed water of HRSG in steam injection cycle from the rejected heat by water coolant of condenser in combined cycle, when using the identical gas turbine and the same amount of total fuel consumption. In general case, formulas and data are given to indicate this comparison by the ratio of steam mass flow supplied by HRSG of the two cycles. The analysis of Cheng Cycle Series 7 is applied as an example to give the practical result.
1989-06-05
Public agency partnership: Hanford`s history artifacts as a communications tool
Energy Technology Data Exchange (ETDEWEB)
The Hanford Site in eastern Washington state currently is engaged in the largest waste cleanup in world history. In order to make informed decisions about remediation options, the public throughout the Pacific Northwest and the nation needs to understand the wastes that are present, their sources of generation, their composition, and their behavior in the environment. The fact that Hanford operations` were conducted in secret for over four decades presents a unique public information challenge to those who currently are responsible for communicating with the public.
1994-02-01
Pion-nucleon charge exchange amplitudes above 2 GeV
Energy Technology Data Exchange (ETDEWEB)
The amplitudes for the pion-nucleon charge exchange reaction of the Karlsruhe-Helsinki and the George-Washington-University partial-wave analyses are compared with those of a Regge-cut model with the aim to explore the possibility to provide high-energy constraints for theoretical baryon resonance analyses in the energy region above 2 GeV. (orig.)
2009-04-15
Melter Disposal Strategic Planning Document
Energy Technology Data Exchange (ETDEWEB)
This document describes the proposed strategy for disposal of spent and failed melters from the tank waste treatment plant to be built by the Office of River Protection at the Hanford site in Washington. It describes program management activities, disposal and transportation systems, leachate management, permitting, and safety authorization basis approvals needed to execute the strategy.
2000-09-25
Independent Media Center - Brazil | Newswire archive
... Research Center, Washington DC May 23 BBC NEws: US used Nuclear Weapons in Afghanistan Jalalabad: New reference levels based on recent samples show uranium levels 45 times normal. New bioassay studies identify uranium internal contamination in Spin Gar (Tora Bora) area and the City ...
... Operational aspects of fiscal policy making in oil-producing countries , in J. Davis, R. Ossowski and A. Fedelino (...), Fiscal Policy Formulation and Implementation in Oil-Producing Countries , International Monetary Fund, Washington, D.C. Barro, R. (...
Energy Technology Data Exchange (ETDEWEB)
This report covers the period from October 1, 1992 to March 1, 1993. The overall goals of the program task are to provide a final synthesis of six deep seismic reflection profiles and other geological and geophysical data from the southern Washington Cascades region where a probable extensive deep sedimentary basin has been discovered. This deep sedimentary basin is hypothesized from geological, regional magnetotelluric (MT), gravity, magnetic , and seismic reflection data as described in the American Association of Petroleum Geologists (AAPG) article by Stanley and others (1992). This report analyzed three seismic reflection profiles acquired by the Morgantown Energy Technology Centers in combination with the extensive MT and other data to outline a probable geological model for a thick conductive section of rocks in the southern Washington Cascades (called the Southern Washington Cascades conductor, SWCC). Earlier MT ...
1993-03-02
Coastal conservation: essays on experiments in governance. [Monograph
Energy Technology Data Exchange (ETDEWEB)
Three book reviews and five essays address the problems of governing coastal regions. The books reviewed and the articles covered the institutions and programs involved in resource management, the balance of local and state interests in coastal conservation and developments, a consensus on coastal planning issues, and a growing trend in state-local collaborative planning. Four of the articles pertain to California, and one focuses on programs in Maine, Rhode Island, and Washington. 135 references. (DCK)
1981-01-01
Cooling of nuclear power stations with high temperature reactors and helium turbine cycles
International Nuclear Information System (INIS)
On nuclear power stations with high temperature reactors and helium turbine cycles (HTR-single circuits) the residual heat from the energy conversion process in the primary and intermediate coolers is removed from cycled gas, helium. Water, which is circulated for safety reasons through a closed circuit, is used for cooling. The primary and intermediate coolers as well as other cooling equipment of the power plant are installed within the reactor building. The heat from the helium turbine cycle is removed to the environment most effectively by natural draught cooling towers. In this way a net plant efficiency of about 40% is attainable. The low quantities of residual heat thereby produced and the high (in comparison with power stations with steam turbine cycles) cooling agent pressure and cooling water reheat pressure in the circulating coolers enable an economically favourable ...
Energy Technology Data Exchange (ETDEWEB)
Secondary energy can be described as a surplus of electrical energy in a hydropower because the lower demand of energy in some period of the day and the excess of water in the reservoir during the rainy periods. This study proposes the using of the excess of energy at Itaipu Bi nacional for electrolytically hydrogen production and ammonia for nitrogenous fertilizers. Ammonia is a raw material for nitrogenous fertilizers synthesis and produced using hydrogen and nitrogen from the atmosphere. This paper determines the minimal cost of hydrogen production and the capacity of hydrogen production, with this data and according the ammonia market for nitrogenous fertilizers in the Centre/South region was estimated the better capacity of ammonia production for one plant near Itaipu. The process of ammonia production using energy excess is the most environmental acceptable. (author)
2000-07-01
Technical Standards for Wolsong Unit 1 Nuclear Power Plant
International Nuclear Information System (INIS)
More than twenty years after commencing commercial operation in 1983, Wolsong Unit 1(W1- NPP), the first CANDU Pressurized Heavy Water Reactor (PHWR) in Korea, has been undergoing refurbishment. Safety analyses were required to evaluate the safety of W1-NPP because significant amount of equipment has been refurbished. To evaluate the effectiveness of W1-NPP after these upgrades, new safety analyses were performed using the same technical standards of Wolsong Units 2, 3, 4 (W234-NPP) for Design Basis Accidents (DBA). The refurbished W1- NPP is expected to be licensed for full power operation based on the verified safety analysis results that are obtained by using the upgraded computer codes and newly adopted technical standards of W234-NPP
2010-10-01
Energy Technology Data Exchange (ETDEWEB)
Calcium sulfate dihydrate which is co-produced in the scrubbing of waste gases from bituminous coal power plants is employed in the underground road securing after recrystallization. Beta-sulfate semi hydrate is obtained from the dihydrate by recrystallisation and it is used as such or as a stiff mixture with additives as a stowing material. Particularly fly ash from coal combustion units, washery refuses and development rocks from coal mining or slags from the metallurgical industry can be used as additives. The compressive and the bending tensile strength of the stowing material can be adjusted by the water content in case beta sulfate semihydrate is used as such.
1980-08-28
Energy Technology Data Exchange (ETDEWEB)
Boiling jet impingement cooling is currently being explored to cool power electronics components. In hybrid vehicles, inverters are used for DC-AC conversion. These inverters involve a number of insulated-gate bipolar transistors (IGBTs), which are used as on/off switches. The heat dissipated in these transistors can result in heat fluxes of up to 200 W/cm{sup 2}, which makes the thermal management problem quite important. In this paper, turbulent jet impingement involving nucleate boiling is explored numerically. The framework for these computations is the CFD code FLUENT. For nucleate boiling, the Eulerian multiphase model is used. The numerical results for boiling water and R113 jets (submerged) are validated against existing experimental data in the literature. Some representative IGBT package simulations that use R134a as the cooling fluid are also presented. (author)
2008-01-15
New sealant for nuclear power station premises of emergency location
International Nuclear Information System (INIS)
When operating a nuclear power plant the necessity arise to eliminate various defects of building constructions, to seal joints and transitional elements. The authors present data concerning the production of a sealing composition made of epoxy resin and used for NPP premises of emergency location. Analytical relations are presented between the properties of the composition (adhesion strength, water absorption and others) and its structure. Physical, mechanical and thermal properties and structural peculiarities are determined in the process of interaction between the filling and binding agents. The composition sustains sealing properties under environmental conditions at he presence of an air - vapour mixture with 160 degrees C"o temperature and 0.3 MPa surplus pressure. (author).
Klickitat Cogeneration Project : Final Environmental Assessment.
Energy Technology Data Exchange (ETDEWEB)
To meet BPA`s contractual obligation to supply electrical power to its customers, BPA proposes to acquire power generated by Klickitat Cogeneration Project. BPA has prepared an environmental assessment evaluating the proposed project. Based on the EA analysis, BPA`s proposed action is not a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act of 1969 for the following reasons: (1)it will not have a significant impact land use, upland vegetation, wetlands, water quality, geology, soils, public health and safety, visual quality, historical and cultural resources, recreation and socioeconomics, and (2) impacts to fisheries, wildlife resources, air quality, and noise will be temporary, minor, or sufficiently offset by mitigation. Therefore, the preparation of an environmental impact statement is not required and BPA is issuing this FONSI ...
1994-09-01
Hydrodynamics induced vibration to trash-racks
International Nuclear Information System (INIS)
In conventional power plants trash-racks are provided at the intakes to protect the turbines. In pumped storage plants, the draft tube or tailrace must also have trash-racks to protect the units while pumping. Because the loads believed to cause many failures of trash-racks are dynamic in nature, it is important to understand the dynamic characteristics of trash-racks structures in general and a single rack in particular. The classical added-mass solution structure-fluid dynamic interaction is known as an approximate solution procedure. An accurate added-mass approach mixed with implementation in finite element framework is proposed. In this proposal, experimental conclusions, supported by theory, led to presentation of more accurate results in vibration of trash-racks. This numerical solution as a powerful method to solve such a complex problem can be employed to carry out dynamic characteristics of these structures while vibrating in ...
2002-12-01
Fingerprint testing of contaminated ventilation extract filter systems at Sizewell B
International Nuclear Information System (INIS)
Sizewell B is Nuclear Electric's latest power station, and the Pressurised Water Reactor (PWR) design on which it is based represents a ''first'' for the UK. One of the integral components of the plant is the heating, ventilation and air-conditioning (HVAC) system, which performs a contamination control and gaseous waste management function for the site. During the commissioning of Sizewell B Power Station the extract systems of the HVAC plant underwent a procedure known as ''fingerprinting''. This entailed the characterisation of the facilities provided to test the filtration plant during its lifetime. The assessment of their adequacy was then used to identify necessary modifications and/or to propose the manner in which future in situ performance testing would be carried out. The paper outlines the basic principles and procedure that was used to ''fingerprint'' test systems during the commissioning of Sizewell B. A ...
Energy Technology Data Exchange (ETDEWEB)
A prototype trumpet type nonimaging secondary concentrator has been designed and fabricated for use with the Cummins Power Generation (CPG) 7.5 kW(e) dish-Stirling system and a preliminary set of operating tests has been carried out. The secondary is 26.7 cm (10.5 in.) deep by about 69 cm (27 in.) wide, and has a geometric concentration of 1.7X. The test units were fabricated from polished copper spinnings, overcoated with vapor deposited aluminum and aluminum oxide layers and are water cooled. The basic design considerations are reviewed, the objectives and test procedures for the experiment are summarized and some preliminary results are presented.
1996-11-01
Electrolytic production of hydrogen utilizing photovoltaic cells
Energy Technology Data Exchange (ETDEWEB)
Hydrogen has the potential to serve as both an energy storage means and an energy carrier in renewable energy systems. When renewable energy sources such as solar or wind power are used to produce electrical power, the output can vary depending on weather conditions. By using renewable sources to produce hydrogen, a fuel which can be stored and transported, a reliable and continuously available energy supply with a predictable long-term average output is created. Electrolysis is one method of converting renewable energy into hydrogen fuel. In this experiment we examine the use of an electrolyzer based on polymer-electrolyte membrane technology to separate water into hydrogen and oxygen. The oxygen is vented to the atmosphere and the hydrogen is stored in a small pressure vessel.
1996-10-01
International Nuclear Information System (INIS)
The tide field at the time of liquid effluent discharging from Daya Bay nuclear power station, and the average water speed at the monitoring points in west Daya Bay from the time of discharging to the time of sampling were calculated by ADI (Alternating Direction Implicit) method. By comparing analysis, the difference of "3H diffusion between spring tide and neap tide (the expansion of "3H within one day of spring tide is greater than that within one day of neap tide) was found. So, an equivalent diffusion time is introduced to modify the original model, and a better attenuation relation between the average "3He concentration in west Daya Bay and the time since the liquid "3H discharging is obtained. (authors)
2006-07-01
Development of sealing insulator for electric penetration assemblies
International Nuclear Information System (INIS)
Electrical penetration assemblies mounted on the containment wall are used to carry electrical power and signals from the equipment inside this containment (e.g. recirculation pumps, control rod position indications etc.) Todays BWR nuclear power plants apply epoxy resin sealed electric penetration. Contrariwise, the epoxy resin (organic sealant) was replaced with sodium barium glass (inorganic) by way of trial in search for a quality sealant. The glass sealant has been proved to have high temperature airtightness at 300 degC above from an evaluation test involving full-scale model parts. Environmental tests were conducted continuously as to heat cycle, vibration and LOCA etc. the specimens (module) of five types. They were made certain of conformity to the design requirements for boiling water operation. (author).
Clean combustion of solid fuels
International Nuclear Information System (INIS)
A chemical-looping process is proposed for the clean combustion of solid fuels for electric power or heat generation. The process is based on coal gasification with CO_2 to produce CO. The CO then reduces CaSO_4, which is used as an oxygen carrier, in a separate reactor to give CaS and CO_2. A portion of the CO_2 is recycled for the gasification stage and the rest can be sent for sequestration. The CaS is sent to another reactor for oxidation with air and to generate heat or power. The overall thermal effect is the same as direct combustion, but separation of CO_2 and other pollutants, such as sulphur, is achieved. In comparison with conventional chemical-looping combustion of natural gas, much less water is present in the CO_2 product, and hence the loss of heat energy and corrosion of the fuel-reactor system can be reduced.
2008-01-01
British Library Electronic Table of Contents (United Kingdom)
The heating of water layer using microwave oven with a rectangular waveguide has been studied both numerically and experimentally. The mathematical model is validated with the experimental data. The transient Maxwell's equations are solved by using the Finite Difference Time Domain (FDTD) method to describe the electromagnetic field inside the waveguide and sample. The temperature profile and velocity field within sample are determined by the solutions of the momentum, energy and Maxwell's equations. In this study, the effects of physical parameters, e.g. microwave power level, placement of sample inside the waveguide, volume of sample, are studied. The distribution of electric field, temperature profile and velocity field are presented in details. The results show good agreement between s...
2012-01-01
Energy Technology Data Exchange (ETDEWEB)
This document presents the analysis of the simulation of the loss of coolant accident at uprate power conditions, that is 2027 MWt (105% of the current rated power of 1931MWt). This power was reached allowing an increase in the turbine steam flow rate without changing the steam dome pressure value at its rated conditions (1020 psiaJ. There are also presented the results of the simulation of the main steam isolation va/ve transient at overpressure conditions 1065 psia and 1067 MWt), for Laguna Verde Nuclear Power Station. Both simulations were performed with the best estimate computer code TRA C BF1. The results obtained in the loss of coolant accident show that the emergency core coolant systems can recover the water level in the core before fuel temperature increases excessively, and that the peak pressure reached in the drywell is always below its design pressure. Therefore it is ...
2001-07-01
International Nuclear Information System (INIS)
Wolsong 2, 3, and 4 are CANDU 6 pressurized heavy water nuclear power plants, each with a gross electrical output of 715 MW(e). The plants were constructed in the Republic of Korea during the 1990s. The three Wolsong units are based on the previous CANDU Wolsong Unit 1, declared in service in 1983. All four units are presently in commercial service. The Wolsong abnormal operating manuals were developed in a cooperative effort between Atomic Energy of Canada Limited, Korea Power Engineering Company staff, and Korea Electric Power Corporation. The role of Atomic Energy of Canada Limited in performing risk assessment studies and supporting CANDU stations for the preparation of emergency operating procedures has greatly benefited the Wolsong abnormal operating manual program. Korea Electric Power Corporation provided training and supervision, Korea Power Engineering ...
Variable-speed generation enhances hydro operation
Energy Technology Data Exchange (ETDEWEB)
Two major developments have given impetus to wider adoption of variable-speed turbine/generators in hydroelectric plants, both essentially environmental: (1) the need for stream-bed stability below river dams, and (2) the need to minimize fish damage. Also, the need to stabilize pumped-storage and generating efficiencies to match extreme changes in head levels has been a driving force. Variable-speed operation in hydro applications is relatively new to North America. In other parts of the world, it has been used in pumped-storage plants since 1971. In the US, and increasing potential exists for variable-speed hydro, considering the 30 pumped-storage plants already in operation and several river plants struggling with high head fluctuations--including four at stations operated by the Bonneville Power Administration. Several modifications to hydro-plant hardware and operating procedures are actively being considered at Bonneville--all of them practical but costly. ...
1993-07-01
Energy Technology Data Exchange (ETDEWEB)
The Berliner Kraft- u. Licht (BEWAG)AG have been conducting investigations during the last several years on a 110 kV low-pressure oil-filled high-power cable with a water cooled conductor and a load capacity of 950 MVA at 110 kV. After successful transport of the cable drums (weight: 16 metric tons; diameter: 4.9 m) from the manufacturing in Cologne, West Germany, to Berlin (West), and after laying of the cable over a 300 m stretch, the commissioning tests in accordance with IEC and VDE* standards have been concluded, and several loadings with a current of 5000 A have been performed. Now, after completion of various improvements in the test system, preparations are underway for initiation of long-term testing over a period of approx. 18 months.
1982-07-01
The RADionuclide Transport, Removal, and Dose (RADTRAD) code
Energy Technology Data Exchange (ETDEWEB)
The RADionuclide Transport, Removal, And Dose (RADTRAD) code is designed for US Nuclear Regulatory Commission (USNRC) use to calculate the radiological consequences to the offsite population and to control room operators following a design-basis accident at Light Water Reactor (LWR) power plants. This code utilizes updated reactor accident source terms published in draft NUREG-1465, ``Accident Source Terms for Light-Water Nuclear Power Plants.`` The code will track the transport of radionuclides as they are released from the reactor pressure vessel, travel through the primary containment and other buildings, and are released to the environment. As the radioactive material is transported through the primary containment and other buildings, credit for several removal mechanisms may be taken including sprays, suppression pools, overlying pools, filters, and natural deposition. Simple models are available ...
1993-07-01
Proceedings of the workshop on radioactivity associated with coal use
Energy Technology Data Exchange (ETDEWEB)
A workshop on radioactivity in coal use was held on September 15 through 17, 1981, under the auspices of the US Department of Energy, Office of Environmental Programs, and the Los Alamos National Laboratory. The purpose of the workshop was to identify research issues associated with radioactivity resulting from the use of coal for electric power generation. The concensus of the 10 scientists participating in the workshop was that a moderate to strong need exists for research in solubility of fly ash in different fluids and for determination of radioactivity in construction materials. Several additional research issues were identified but were given a lower priority. Summaries of each presentation are included. Titles are: some effects of coal combustion on the radiation environment; radionuclides in western coal at Mound; low-level radiation in coals utilized and ashes produced at New York State electric utilities; radioactivity from coal use - where are the ...
1981-12-01
Life estimation of high-voltage electric cable. Koden prime atsu cable no jumyo yosoku
Energy Technology Data Exchange (ETDEWEB)
An explanation is given of life estimation of CV cable and OF cable which are generally used as high-voltage power cable. CV cable uses XLPE (crosslined polyethylene) and OF cable uses oil-immersed paper as electrical insulators. Relating to CV cable, voltage deterioration due to partial discharge and electric treeing occurs in a high electric field, and by extrapolating the data of up to the actually used electric field in this high electric field, the life is estimate (there is an n-power deterioration law which is V{sup n} = t between breakdown voltage V and electric applied time t). Validity of this extrapolation, however, is a future issue. Further, in the use under the immersion condition, water tree deterioration phenomena influenced by water content and the electric field which are characteristic of CV cable are seen even in the actually used low electric field, and the life index becomes ...
1991-12-15
Conceptual fusion power monitor based on the "1"6O(n,p)"1"6N reaction
International Nuclear Information System (INIS)
The feasibility of developing a fusion power monitor based on a fluid activation detector is considered here. The activation fluid may be either a liquid or a gas and its composition can be selected from a number of candidate materials to provide desired activation and decay characterisitcs. Performance calculations indicate that ordinary water would be a nearly ideal activation fluid. The "1"6O(n,p)"1"6N reaction has a threshold at about 10 MeV and a cross section energy dependence giving it a predominant response for unmoderated D-T fusion neutrons. Adequate activation can be obtained at moderate flow rates for remote counting away from the high radiation area of the reactor. The 7.16 sec half-life of "1"6N is ideal for remote counting with subsequent decay in a small hold-up tank to eliminate activity build-up in the recycled water.
1981-07-01
Energy Technology Data Exchange (ETDEWEB)
The core bypass phenomenon of borated water injected through direct vessel injection (DVI) nozzles in APR1400 (Advanced Power Reactor 1400MWe) during main steam line break (MSLB) accidents with a reactor coolant pump (RCP) running mode has been simulated using a two-channel and one-dimensional system analysis model code (MARS), and a three-dimensional computational fluid dynamics (CFD) code (FLUENT). A visualization experiment has also been performed using a scaled-down model of the APR1400. The MARS analysis has predicted a serious core bypass phenomenon of borated water, while the CFD analysis has shown results opposite to the MARS results. The CFD analysis has shown that the flow pattern in the downcomer is fully three-dimensional and that vortex flow structures are formed near the cold legs so that the borated water might pass without difficulty into the high flow region of the cold legs and flow ...
2007-04-15
In situ heat transfer in man-made geothermal energy reservoirs
Energy Technology Data Exchange (ETDEWEB)
Two hot dry rock geothermal energy reservoirs were created by hydraulic fracturing of Precambrian granitic rock on the west flank of the Valles Caldera, a dormant volcanic complex, in the Jemez Mountains of northern New Mexico. Heat was extracted in a closed-loop mode of operation, injecting water into one well and extracting the heated water from a separate production well. The first reservoir was produced by fracturing the injection well at a depth of 2.75 km (9020 ft) where the indigenous rock temperature was 185/sup 0/C. The relatively rapid thermal drawdown of the water produced from the first reservoir, 100/sup 0/C in 74 days, indicated that its effective fracture radius was about 60 m (200 ft). Average thermal power extracted was 4 MW. A second, larger reservoir was created by refracturing the injection well 180 m (600 ft) deeper. Downhole measurements of the water ...
1980-01-01
A model for the calculation of vent clearing transients in pressure suppression systems
International Nuclear Information System (INIS)
For the layout of a pressure suppression system of a light water cooled reactor (boiling water reactor) it is important to know the time dependent behavior of the vent clearing transient after a loss-of-coolant accident for two main reasons: time of the end of the vent clearing transient influences strongly the pressure and temperature maxima in the drywell and wetwell. Time-dependent behavior of the vent clearing transient influences pressure loads in the condensation pool of the wetwell and therefore pressure induced stresses to the structure. The time-dependent behavior of the water masses in the vent pipes and wetwell are described by the basic equations for a nonstationary incompressible friction flow: momentum equation, continuity equation and a correlation for the variation of the state of the gas volume in the wetwell above the water level. After many algebraic operations and integrations along ...
1975-09-01
Snow Survey & Water Supply | NRCS
Programs & Services Technical Resources Land Use Soils Water Snow Survey & Water Supply Water Management Water Quality Watersheds Wetlands Air Plants & Animals Energy Climate...
2011-08-21
Will the concept of protection of existing status persist?; Hat der Bestandsschutz noch Bestand?
Energy Technology Data Exchange (ETDEWEB)
Reviewing all hitherto known plans or drafts for a reform of the atomic energy law, one can expect that the current legal concept of affording protection of existing (legal) status of nuclear facilities will not essentially be watered down by future developments, unless an act is passed for a nuclear power phase-out. (orig.) [Deutsch] Die bislang bekannt gewordenen Reformbestrebungen legen die Vermutung nahe, dass der Bestandsschutz fuer atomrechtliche Anlagen, sofern nicht ein Kernenergie-Abwicklungsgesetz zum Tragen kommt, mit Abstrichen auch in Zukunft rechtlichen Bestand haben wird. (orig.)
1995-12-31
Understanding and protecting steam generator materials
Solid solution-strengthened nickel base alloys have been used for nuclear stream generator tubing in pressurized water reactors since the beginnings of commercial nuclear power. The purpose of this paper is to recap and update the authors understanding of the relationship between processing, resulting structure, and properties for Alloy 600 and to discuss the requirements for optimized performance in both primary and secondary environments. Potential replacement materials and their performance will be discussed. Also discussed is the role and importance of system chemistry, bulk and local, and control and its relationship to performance. A discussion of potential mechanisms of environmentally assisted failure is also discussed.
1986-01-01
Understanding and protecting steam generator materials
International Nuclear Information System (INIS)
Solid solution-strengthened nickel base alloys have been used for nuclear stream generator tubing in pressurized water reactors since the beginnings of commercial nuclear power. The purpose of this paper is to recap and update the authors understanding of the relationship between processing, resulting structure, and properties for Alloy 600 and to discuss the requirements for optimized performance in both primary and secondary environments. Potential replacement materials and their performance will be discussed. Also discussed is the role and importance of system chemistry, bulk and local, and control and its relationship to performance. A discussion of potential mechanisms of environmentally assisted failure is also discussed.
1986-11-16
Energy Technology Data Exchange (ETDEWEB)
The rate at which full-scale technology transfer takes place depends on the quality of the supply companies, i.e. training, organisational development and product infrastructure. These parameters are discussed for the example of a water mill, and a flow diagram is presented. [Deutsch] Wie rasch ein umfassender Transfer in Frage kommt, entscheidet sich mit der Qualitaet und dem Niveau der zuliefernden Betriebe. Hierbei sind Ausbildung, Organisationsentwicklung und Produktionsinfrastruktur besonders angesprochen. Fuer eine Wassermuehle werden diese Parameter konkret eroertert und an Durchlaufdiagrammen erlaeutert. (GL)
1997-12-31
Summary on performance study of corrosion resistance of zirconium alloys
International Nuclear Information System (INIS)
Zirconium-base alloys are used primarily as fuel cladding material and other core structure material in water cooled nuclear power reactors. Main research achievements and problems about corrosion of zirconium alloys are reviewed; the present theories and challenge are summarized. In the 1980s, great progress had been made towards correlating alloy composition, microstructure and irradiation with corrosion resistance. In the 1990s, main researches are focused on exploring actual mechanism of corrosion, optimizing both alloy composition and microstructure in order to minimize the fuel cycle costs through burnup optimization.
Steam generator tube performance
International Nuclear Information System (INIS)
A review of the performance of steam generator tubes in 116 water-cooled nuclear power reactors showed that tubes were plugged at 54 (46 percent) of the reactors. The number of tubes removed from service decreased from 4 692 (0.30 percent) in 1981 to 3 222 (0.20 percent) in 1982. The leading causes of tube failures were stress corrosion cracking from the primary side, stress corrosion cracking (or intergranular attack) from the secondary side and pitting corrosion. The lowest incidence of corrosion-induced defects from the secondary side occurred in reactors that have used only volatile treatment, with or without condensate demineralization.
2005-10-27
Energy Technology Data Exchange (ETDEWEB)
In order to realize improve of reliability and economy by duplicate production, rapid supply of repair parts from standardized storage, such were expected as to have continuous order of standardized plant, to ignore site condition, to avoid expansion of regulatory requirement. Standardization program was planned to limitedly promote standardization of safety-related design concept, major specification and basic system composition of reactor and primary systems. The area of standardization had been tried to expand to BOP such as general arrangement and rad-waste system.
1985-07-01
Relining of scrubbers in flue gas desulfurization plants
Rubber lining is used as a corrosion protection material in European flue gas desulfurization plants, for scrubbers, tanks, pipe systems, etc. Although these rubber linings can last more than 15 years, relining still is necessary. The difficulty of shutting down power station units requires that the time scale of this replacement be kept to a minimum. High-pressure water systems have proven successful as an efficient method for removal of the old lining. The working steps and time scale are demonstrated for one such relining case.
1999-09-01
Investigations were conducted at Los Alamos National Laboratory to quantify the extent of migration of depleted uranium away from firing sites. Extensive sampling of air particles, soil, sediment, and water was conducted to establish the magnitude of uranium contamination throughout one watershed. The uranium source term was estimated, and mass balance calculations were performed to compare the percentage of migrated uranium with original expenditures. Mass balance calculations can be powerful in identification of the extent of waste migration and used as an aid in planning future waste investigations.
1992-02-01
Energy Technology Data Exchange (ETDEWEB)
The restricted temperature stability of the synthetic thermal oil which is used as heat carrier fluid in parabolic trough collectors so far limits the live steam parameters in the steam cycle to approximately 375 Celsius. In order to break through this limit, already for quite some time it is researched to replace the thermal oil by boiler feeding waters and to accomplish the evaporation in the collectors. The contribution under consideration gives an overview on the direct evaporation concept and summarizes the past operational experiences. Moreover, the challenges with the integration of this technology in a steam turbine cycle are elaborated.
2008-07-01
Improvement of FLOWER code and its application in Daya Bay
International Nuclear Information System (INIS)
FLOWER, a computer code recommended by USNRC for assessing the environmental impact in tidal regions, was adapted and improved so as to be suitable to deal with the influence of drift stream along seashore to the dilution of contaminants and heat in the bay mouth. And the code outputs were presented with more mid-results such as average concentrations and temperature values for all tides considered. Finally, the modified code is applied to the dispersion calculation of heat and liquid effluents from Daya Bay Nuclear Power Plant, and the impacts from routine operation of the plant on Daya Bay sea waters were given.
FORTUM Participation in BARCOM Round Robin pre-test simulation: mid-term analysis
Energy Technology Data Exchange (ETDEWEB)
In the study a preliminary mid-term analysis of the BARCOM test model is presented. The BARCOM test model is a 1:4 scale of an existing pressurized heavy water reactor (PHWR) pre-stressed concrete inner containment of 540 MW Tarapur Atomic Power Station 3 and 4 units in India. The goal of this midterm analysis is to illustrate the modeling approach and achieve a prediction of the failure mode. The analysis was carried out using ABAQUS/CAE and ABAQUS/EXPLICIT version 6.7-EF1 software
2009-07-01
Energy Technology Data Exchange (ETDEWEB)
This document provides guidance for modeling and inspecting energy-efficient property in commercial buildings for certification of the energy and power cost savings related to Section 179D of the Internal Revenue Code enacted in Section 1331 of the 2005 Energy Policy Act and noted in Internal Revenue Service Notice 2006-52. Specifically, Section 179D provides federal tax deductions for energy-efficient property related to a commercial building's envelope; interior lighting; heating, ventilating, and air conditioning; and service hot water systems.
2007-05-01
Energy Savings Modeling and Inspection Guidelines for Commercial Building Federal Tax Deductions
Energy Technology Data Exchange (ETDEWEB)
This document provides guidance for modeling and inspecting energy-efficient property in commercial buildings for certification of the energy and power cost savings related to Section 179D of the Internal Revenue Code enacted in Section 1331 of the 2005 Energy Policy Act and noted in Internal Revenue Service Notice 2006-52. Specifically, Section 179D provides federal tax deductions for energy-efficient property related to a commercial building's envelope; interior lighting; heating, ventilating, and air conditioning; and service hot water systems.
2007-02-01
Corrosion cracking of rotor steels of steam turbines
International Nuclear Information System (INIS)
Results of investigation of stress corrosion cracking of steam turbine materials in nuclear, fossil and geothermal power plants have been analysed. The role of factors that cause damage to rotor discs, mono block and welding rotors of steam turbines has been shown. These are yield stress and steel composition, stress intensity coefficient and crack growth rate, composition and temperature of the condensed steam and water, electrochemical conditions. The conclusion has been made about the state of stress corrosion cracking of the rotors materials, and main investigation trends which are necessary to solve this problem have been listed.
Annual Report 2007. Nuclear Regulatory Authority
International Nuclear Information System (INIS)
The present Annual Report of Activities of the Nuclear Regulatory Authority (ARN), prepared regularly from the creation as independent institution, describes across tree parts and seven annexes the activities developed by the organism during 2007. The main topic are: the organization and the activity of the ARN; the regulatory standards; the licensing and inspection of nuclear power plants and critical facilities; the emergency systems; the occupational surveillance; the environmental monitoring; improved organizational. Also, this publication have annexes with the following content: regulatory documents; inspections to medical, industrial and training installations; regulatory guides; measurement and evaluation of the drinking water of Ezeiza.
2004-07-11
Airport expansion requires major wetlands mitigation project
Energy Technology Data Exchange (ETDEWEB)
This article describes the steps taken to mitigate the impact to existing wetlands by creating new wetlands in an airport expansion project. The project addressed maintaining suitable amounts of wetlands to accommodate peak waterfowl populations, moving of high voltage power transmission towers, and maintaining agricultural and hunting interests. This project involved recreating of open water areas, marsh habitat, mud flat habitat, saline meadow habitat, maintaining two existing wetlands in the area of the new wetlands without disturbing them, and improving upland habitat surrounding the new wetlands.
1994-01-01
Numerical simulation of progressive inlet orifices in boiling water reactor fuel
International Nuclear Information System (INIS)
This thesis was carried out at Forsmark Nuclear Power Plant. The power plant in Forsmark consists of three boiling water reactors (BWR) which produce about 17% of Swedish electricity. In a BWR the nuclear reactions are used to boil water inside the reactor vessel. The water works both as a coolant and as a moderator and the resulting steam is used directly to run the turbines. A problem when running a BWR at low flow conditions is the density wave oscillations that might occur to the water flow inside the fuel assemblies. These oscillations arise due to the connection between power and flow rate in a heated channel with two-phase flow. In order to improve the stability performance of the channel an orifice plate is placed at the inlet of each fuel assembly. Today these orifice plates have sharp edges and a constant resistance coefficient. ...
2004-01-01
Horizontal Steam Generator Thermal-Hydraulics at Various Steady-State Power Levels
Three-dimensional computer simulation and analyses of the horizontal steam generator thermal-hydraulics of the WWER 1000 nuclear power plant have been performed for 50% and 75% partial loads, 100% nominal load and 110% over-load. Presented results show water and steam mass flow rate vectors, steam void fraction spatial distribution, recirculation zones, swell level position, water mass inventory on the shell side, and other important thermal-hydraulic parameters. The simulations have been performed with the computer code 3D ANA, based on the 'two-fluid' model approach. Steam-water interface transport processes, as well as tube bundle flow resistance, energy transfer, and steam generation within tube bundles are modelled with {sup c}losure laws{sup .} Applied approach implies non-equilibrium thermal and flow conditions. The model is solved by the control volume procedure, which has been ...
2002-07-01
Horizontal Steam Generator Thermal-Hydraulics at Various Steady-State Power Levels
International Nuclear Information System (INIS)
Three-dimensional computer simulation and analyses of the horizontal steam generator thermal-hydraulics of the WWER 1000 nuclear power plant have been performed for 50% and 75% partial loads, 100% nominal load and 110% over-load. Presented results show water and steam mass flow rate vectors, steam void fraction spatial distribution, recirculation zones, swell level position, water mass inventory on the shell side, and other important thermal-hydraulic parameters. The simulations have been performed with the computer code 3D ANA, based on the 'two-fluid' model approach. Steam-water interface transport processes, as well as tube bundle flow resistance, energy transfer, and steam generation within tube bundles are modelled with "closure laws". Applied approach implies non-equilibrium thermal and flow conditions. The model is solved by the control volume procedure, which has been extended in order to take ...
2002-04-14
GE's advanced nuclear reactor designs
International Nuclear Information System (INIS)
The excess of US electrical generating capacity which has existed for the past 15 years is coming to an end as we enter the 1990s. Environmental and energy security issues associated with fossil fuels are kindling renewed interest in the nuclear option. The importance of these issues are underscored by the National Energy Strategy (NES) which calls for actions which open-quotes are designed to ensure that the nuclear power option is available to utilities.close quotes Utilities, utility associations, and nuclear suppliers, under the leadership of the Nuclear Power Oversight Committee (NPOC), have jointly developed a 14-point strategic plan aimed at establishing a predictable regulatory environment, standardized and pre-licensed Advanced Light Water Reactor (ALWR) nuclear plants, resolving the long-term waste management issue, and other open-quotes enabling conditions.close quotes GE is participating in this national effort ...
1993-07-01
Water in chalk reservoirs: 'friend or foe?'
International Nuclear Information System (INIS)
Most of the petroleum fields in the Norwegian sector of the North Sea are sandstone reservoirs; the oil and gas are trapped in different species of sandstone. But the Ekofisk Field is a chalk reservoir, which really challenges the operator companies. When oil is produced from chalk reservoirs, water usually gets in and the reservoir subsides. The subsidence may be expensive for the oil companies or be used to advantage by increasing the recovery rate. Since 60 per cent of the world's petroleum reserves are located in carbonate reservoirs, it is important to understand what happens as oil and gas are pumped out. Comprehensive studies at the Department of Petroleum Technology and Applied Geophysics at Stavanger University College in Norway show that the mechanical properties of chalk are considerably altered when the pores in the rock become saturated with oil/gas or water under different stress conditions. The processes are extremely complex. ...
International Nuclear Information System (INIS)
The paper discusses the safety problems connected with the conversion to dense storage of RBMK-1000 spent fuel in reactor cooling pools and independent storage facilities. Recourse to dense storage has been made for a number of reasons, among which are the absence of spent fuel shipments from the nuclear power plant site, prolongation of storage time and a partial change in storage conditions. Increasing the storage density per unit volume of the storage facility and turning to new technical procedures (as against the basic design) call for further investigation of safety problems. The safety assessment of the dense storage mode includes: (1) Selecting a list of initiating events for design basis and unforeseeable accidents; (2) Assessing dense storage safety under normal as well as design basis accident conditions; (3) Safety analysis and development of measures to compensate for unforeseen accidents. Based on the studies performed, suggestions have been advanced ...
1995-08-01
Energy Technology Data Exchange (ETDEWEB)
Operation safety and reliability are major guidelines in the design of city-gate units. Conventional natural gas heaters operate by a indirect mechanism, where liquid water is used to transfer heat by natural convection between the combustion chamber and the natural gas coil. In this work, the concept of vapor chamber is evaluated as an indirect gas heater. In a vapor chamber, liquid water is in contact with the heat source, and vaporizes. The vapor condenses in contact with the heat sink. A reduced scale model was built and tested in order to compare these two heating concepts where the combustion chamber was replaced by electrical cartridge heaters. This engineering model can operate either as a conventional heater or as a vapor chamber. The comparison between the concepts was done by inducing a controlled power to the cartridges and by measuring the resulting temperature distributions. In the novel design, the heat ...
2005-07-01
International Nuclear Information System (INIS)
The Swedish State Power Board has together with Nukem, Hanau, West-Germany carried out pyrolysis o powder resins in a pilot plant with a capacity of about 30 kg/hr. The pyrolysis reactor with its afterburner and offgas scrubber system has been operated under steady state condition. About 2200 kg resins have been pyrolysed under November-December 1983 and the decontamination factor for Cs has been measured. Solidification of the residues from the pyrolysis reactor and scrubber water solutions has been carried out and various recipes with cement have been tested. The pyrolysis process has high decontamination factors and no offgas problems as the operating temperature of the reactor is Low. The residues from the reactor are chemically dead and can not cause swelling problems. Compared with a normal cementation process the final waste volume will be reduced with a factor of 4 if also the scrubber water after neutralization is ...
Environmental management plan for the Jhario coalfield - India
Energy Technology Data Exchange (ETDEWEB)
An Environmental Management Plan (EMP) for the Jharia Coalfield (JCF) was recently completed as part of a World Bank funded project. The JCF, 260 km west of Calcutta, comprises 450 km{sup 2}. Bharat Coking Coal Limited (BCCL) operates an area of 258 km{sup 2}. Coal mining has been conducted for more than 100 years. There are severe constraints to mining due to geology, coal fires and the large population. BCCL counterpart staff participated actively in all aspects of the work. Air and water are heavily polluted, however, mining operations contribute only to a limited extent to the total pollution. Water contamination is generally due to inadequate sewage treatment and discharge from non-mine facilities such as power plants. The large area disturbed by mining to date will increase, as open pit mining operations are expected to expand significantly. Reclamation to date is generally confined to planting of trees. Areas where ...
1997-12-31
Corrosion failure and its prevention in light water reactor power plants
Energy Technology Data Exchange (ETDEWEB)
During 17 years since the start of operation of the first commercial LWR in Japan, many LWRs have experienced various corrosion damages, but the causes of them were clarified, and the counter-measures were executed effectively in actual plants, as the results, the cause of corrosion damage decreased remarkably, and now, the high rate of operation has become to be maintained. In this paper, the major cases of corrosion damage experienced in LWRs in Japan and foreign countries, the causes of them and the countermeasures, the problems of hereafter and so on are described. The corrosion damage of metallic materials in the environment of LWRs occurs in the parts in contact with high temperature, high pressure water and steam, such as stainless steel piping in the primary cooling system of BWRs, and nickel alloy heating tubes of steam generators, carbon steel feed water piping and zirconium alloy fuel cladding tubes in PWRs. Recently, accompanying ...
1988-01-01
Corrosion failure and its prevention in light water reactor power plants
International Nuclear Information System (INIS)
During 17 years since the start of operation of the first commercial LWR in Japan, many LWRs have experienced various corrosion damages, but the causes of them were clarified, and the counter-measures were executed effectively in actual plants, as the results, the cause of corrosion damage decreased remarkably, and now, the high rate of operation has become to be maintained. In this paper, the major cases of corrosion damage experienced in LWRs in Japan and foreign countries, the causes of them and the countermeasures, the problems of hereafter and so on are described. The corrosion damage of metallic materials in the environment of LWRs occurs in the parts in contact with high temperature, high pressure water and steam, such as stainless steel piping in the primary cooling system of BWRs, and nickel alloy heating tubes of steam generators, carbon steel feed water piping and zirconium alloy fuel cladding tubes in PWRs. Recently, accompanying ...
Behavior of ice covers subjected to large daily flow and level fluctuations
Energy Technology Data Exchange (ETDEWEB)
The stability of a solid ice cover subjected to rapidly varying water levels and discharge was investigated. The support from the bank limits the stress in the ice cover and consequently bank contact must be maintained to ensure ice cover stability. An analysis was required of the stability of ice hinges, a flexible connection between a solid ice cover and the riverbank. Phase II and phase III of the research involved a field study of the Peace River, investigating the evolution of ice hinges with water level variation, from initial ice cover cracking parallel to the banks, to a fully developed hinge. A test program of midwinter discharge variations was undertaken to gather specific data and measurements of ice hinge link length, ice thickness, hinge joint behavior, riverbank geometry, and response of ice hinging to water level variation. As a result of the program, concepts developed throughout the study were confirmed, ...
1984-11-01
Actinides in liquid waste formed in the regeneration of nuclear fuel from a VVER-1000 reactor
International Nuclear Information System (INIS)
In the radiochemical reprocessing of spent fuel from nuclear reactors, a considerable amount of liquid, solid, and gaseous waste is formed; this waste is potentially dangerous to humans and requires the development of special and complex technological techniques for its localization and reliable long-term storage. The most hazardous are liquid wastes of high specific activity - water-tailings solutions obtained in the first cycle of extraction after the removal of uranium and plutonium. These solutions contain more than 99.9% of all the other transuranic elements - isotopes of neptunium, americium, and curium. Where necessary, some fission products and actinides may be removed from wastes of high specific activity for subsequent use. The quantity, composition, and activity of these wastes varies within broad limits, depending on the type and power of the reactor, the initial nuclide composition of the fuel, and its specific energy yield, the ...
Present status of study on reduced-moderation water reactors
Energy Technology Data Exchange (ETDEWEB)
The Reduced-Moderation Water Reactor (RMWR) is a next generation water-cooled reactor, based on the experienced light water reactor (LWR) technology, aiming at effective utilization of uranium resources, high burn-up and long operation cycle and plutonium multiple recycling. These characteristics can be achieved by the high conversion ratio from {sup 238}U to {sup 239}Pu resulted from the higher neutron energy spectrum in comparison to conventional LWRs. Considering the extension of LWR utilization, Japan Atomic Energy Research Institute (JAERI) started the research on it in 1997 and then started a collaboration in the conceptual design study with the Japan Atomic Power Company (JAPC) in 1998, under technical cooperation with three Japanese reactor vendors. In the core design study of the RMWR, several basic core designs with the high conversion ratio more than 1 and the negative void reactivity ...
2001-09-01
International Nuclear Information System (INIS)
Research highlights: ? We model power oscillations in boiling water reactors using a lumped parameter model. ? The nature and amplitudes of oscillations is obtained using a nonlinear analysis. ? The method of multiple scales has been used for the analytical treatment. ? Fuel temperature coefficient of reactivity determines the nature of oscillations. ? The presented systematic method of analysis useful for reduced order reactor models. - Abstract: In this paper, we perform a parametric study of the nonlinear dynamics of a reduced order model for boiling water reactors (BWR) near the Hopf bifurcation point using the method of multiple scales (MMS). Analysis has been performed for general values of the parameters, but the results are demonstrated for parameter values of the model corresponding to the advanced heavy water reactor (AHWR). The neutronics of the AHWR is modeled using point reactor kinetic ...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The generation of thermal energy is the great importance for the agribusiness of dairy industry to conservation the quality of milk, taking into account that the electricity is the main source currently used for the thermal energy input. The small agribusiness dairy industry currently practiced in Brazil faces several problems related to the cost of electricity and the distance of rural properties of networks of power. In the current scenario of Brazilian dairy production, there is need for the generation of cold for the milk cooling, and also the heat for the production of hot water around 50 deg C to 60 deg C and also for cleaning of equipment used for milk production and processing. The main objective of this study is the modeling and simulation of integrated recovery process of solid waste, effluents and bioconversion. The specific project objectives are: comparison study of options and technological routes of low cost material for ...
2008-07-01
Reconsidering the site requirements for NPP on Olt River
International Nuclear Information System (INIS)
Site studies for CANDU type NPP began in a careful manner since 1982 as a first part of the Nuclear Power Plant Romanian Program adopted by political and governmental authorities at the time. A team was charged to develop all packages of the necessary main studies. The first Romanian NPP CANDU 6 type reactor gone to erection on Cernavoda site, planned to have 5 units and, like Wolsong NPP, applied the same design for the nuclear island. For the BOP parts the ANSALDO-GE project was applied with a thorough concern about requirements raised by connection to NSP. The first mission of design and research multi-branch team was to adapt the NPP Cernavoda project having an open water cooling circuit 'once-through' to the new parameters of a close recirculation water cooling circuit. Also, the structural design was re-evaluated for the case of soft foundation strata instead of hard rock ones. The close recirculation ...
2009-10-12
Energy Technology Data Exchange (ETDEWEB)
The Tennessee Valley Authority (TVA), the Electric Power Research Institute (EPRI), and the Department of Energy-National Energy Technologies Laboratory (DOE-NETL) are evaluating and demonstrating integration of terrestrial carbon sequestration techniques at a coal-fired electric power plant through the use of Flue Gas Desulfurization (FGD) system gypsum as a soil amendment and mulch, and coal fly ash pond process water for periodic irrigation. From January to March 2002, the Project Team initiated the construction of a 40 ha Carbon Capture and Water Emissions Treatment System (CCWESTRS) near TVA's Paradise Fossil Plant on marginally reclaimed surface coal mine lands in Kentucky. The CCWESTRS is growing commercial grade trees and cover crops and is expected to sequester 1.5-2.0 MT/ha carbon per year over a 20-year period. The concept could be used to meet a portion of the timber ...
2005-08-30
Energy Technology Data Exchange (ETDEWEB)
This study resumes the discovery of an excess of actinium 227 found around by EL4 nuclear reactor actually in dismantling. The search for the origin of this excess revealed a real inquiry of investigation during three years. Because a nuclear reactor existed in this area a particular attention will have concerned this region. The doubt became the line of conduct to find the answer to the human or natural origin of this excess. Finally and against any evidence, it appears that the origin of this phenomenon was natural, consequence of the particular local geology. The detail of the different investigations is given: search of a possible correlation with the composition of elevations constituent of lanes, search (and underlining) of new sites in the surroundings of the Rusquec pond and the Plouenez station, study of the atmospheric deposits under winds of the nuclear power plant and in the east direction, search of a possible relationship with the gaseous effluents of ...
2007-07-01
Long-term optimization of fuel loading pattern using genetic algorithms and simulated annealing
International Nuclear Information System (INIS)
This paper describes Automatic Refueling Planning System (ARPS) for a nuclear power station using Genetic Algorithms (GA) and a Simulated Annealing (SA). ARPS has been developed and verified by applying to the Fugen nuclear power station (NPS), which is a 165MWe, heavy water-moderated, boiling light water-cooled, pressure tube-type reactor developed by JNC utilizing mainly uranium and plutonium mixed oxide (MOX) fuel. Fuel loading patterns have been managed independently in the Fugen NPS since the initial core. A planning of an adequate fuel loading pattern on each operational cycle needs one to two months even for expert core management engineers, for the reason that it has multi-objective optimization and nonlinear problems. In order to achieve the optimum fuel loading pattern and a fuel cost reduction, ARPS has been developed by JNC and CRC Solutions Corporation for the last five years. ARPS firstly ...
2003-04-20
Korean experience in CANDU-PHWR operation
Among KEPCO's 9 nuclear power units, Korea Nuclear Unit No. 3, the Wolsung Nuclear Power Plant is the only CANDU-PHWR Unit, while the rest of 8 others are PWR units. The unit was designed by Atomic Energy of Canada, Ltd. of Canada, who also performed overall project management for the plant construction under the provisions and arrangement of the relevant contracts. The gross electrical output of the plant is 678.7 MWe and thermal output of the reactor is 2061 MWth. While these figures lead to lower plant efficiency than LWR counterparts, unit energy cost for fuel is more favorable than LWRs because natural uranium is utilized for the fuel bundles, some of which are already being fabricated domestically. Annual capacity factors for 1983 and 1984 could have been improved, if two major planned outages for the modification works on steam generator internals and one major forced outage from the heavy water spill ...
1988-01-01
HVDC submarine power cables systems state of the art and future developments
Energy Technology Data Exchange (ETDEWEB)
The paper begins with an introduction on the reasons that lead to the use of HVDC submarine cable links. The main aspects for the choice of direct current are presented as well as the advantages deriving from the utilization of submarine cables. The second part is dedicated to a discussion on the various type of insulation that could be used in power cables and their possible application to HVDC submarine cables. In the following there is a description of the main characteristics and technical details of some particular project that at present time (1995) are in progress. Two projects are briefly presented: Spain-Morocco, a 26 km long interconnection for the transmission, in a first phase, of 700 MW from Spain to Morocco at 400 kV a.c. by means of three cables, plus one spare, of the fluid filled type. The cables are designed for a future change to d.c. 450 kV, allowing a transmission of 500 MW each (i.e., 2 GW total). One of the peculiarities of the link is the ...
1995-12-31
Wall thinning trend analyses for secondary side piping of Korean NPPs
International Nuclear Information System (INIS)
Since the mid-1990s, nuclear power plants in Korea have experienced wall thinning, leaks, and ruptures of secondary side piping caused by flow-accelerated corrosion (FAC). The pipe failures have increased as operating time progresses. In order to prevent the FAC-induced pipe failures and to develop an effective FAC management strategy, KEPRI and KOPEC have conducted a study for developing systematic FAC management technology for secondary side piping of all Korean nuclear power plants. As a part of the study, FAC analyses were performed using the CHECWORKS code. The analysis results were used to select components for inspection and to determine inspection intervals on each nuclear power plant. This paper describes the introduction of the FAC analysis method and the wall thinning trend analysis results by reactor type, system, and water treatment amine. This paper also represents the site application ...
2003-08-17
Space effect on liquid film flow in a BWR fuel bundle
Critical power at boiling transition is an important factor in a boiling water reactor (BWR) fuel bundle design. Boiling transition under high quality accounts for dryout as the result of the complete disappearance of film flow on a fuel rod. This liquid film vanishing process can be calculated by the liquid film model, which takes into account the evaporation due to heat from the rod surface, liquid film entrainment by steam flow, and liquid droplet deposition. It is known that spacers affect liquid film entrainment and liquid droplet deposition, so the detailed study of spacer effects on hydrodynamic characteristics is necessary for critical power prediction based on the film flow model. Many studies have been conducted to examine spacer effects on liquid film flow. However, most of them are restricted to simple test sections such as a rectangular conduit. There are a few reports on fuel bundle geometry; however the ...
1991-01-01
Some highlights of phase-C commissioning of Tarapur-4 the first to be synchronized 540 MWe PHWR
International Nuclear Information System (INIS)
Commissioning of a Pressurized heavy water reactor (PHWR) plant of NPCIL involves three phases viz phase-A which consist of pre-criticality activities such as hydro test, air hold test, no load test of motors etc., phase-B consist of criticality and post criticality physics experiments. The phase-C, which is considered the major phase, consist of initial power raise to about 10 % , TG rolling, synchronization, going to significant power in steps and performance tests such as load rejection tests from various power levels. In order to have smooth commissioning for the Phase-C, an integrated team consisting of engineers from various design and analysis groups of NPCIL headquarters was formed to participate along with site O and M engineers, closely observe and coordinate phase-C commissioning activities. During this commissioning some major events and observations took place. An attempt is made to bring ...
2006-11-13
Energy Technology Data Exchange (ETDEWEB)
The requirements to design nuclear power plants for the effects of an instantaneous double-ended guillotine break (DEGB) of the reactor coolant piping have led to excessive design costs, interference with normal plant operation and maintenance, and unnecessary radiation exposure of plant maintenance personnel. This report describes an aspect of the NRC/Lawrence Livermore National laboratory-sponsored research program aimed at investigating whether the probability of DEGB in Reactor Coolant Loop Piping of nuclear power plants is acceptably small such that the requirements to design for the DEGB effects (e.g., provision of pipe whip restraints) may be removed. This study estimates the probability of indirect DEGB in Reactor Coolant piping as a consequence of seismic-induced structural failures within the containment of the GE supplied boiling water reactor at the Brunswick nuclear power plant. The median ...
1986-12-01
Optimized, Competitive Supercritical-CO_2 Cycle GFR for Gen IV Service
International Nuclear Information System (INIS)
An overall plant design was developed for a gas-cooled fast reactor employing a direct supercritical Brayton power conversion system. The most important findings were that (1) the concept could be capital-cost competitive, but startup fuel cycle costs are penalized by the low core power density, specified in large part to satisfy the goal of significant post-accident passive natural convection cooling; (2) active decay heat removal is preferable as the first line of defense, with passive performance in a backup role; (3) an innovative tube-in-duct fuel assembly, vented to the primary coolant, appears to be practicable; and (4) use of the S-Co2 GFR to support hydrogen production is a synergistic application, since sufficient energy can be recuperated from the product H2 and 02 to allow the electrolysis cell to run 250 C hotter than the reactor coolant, and the water boilers can be used for reactor decay heat removal. ...
Nuclear power plant support activities in reactors chemistry at CNEA
International Nuclear Information System (INIS)
Argentina has two operating PHWR nuclear power plants. Atucha I NPP is a pressure vessel type heavy water reactor of 360 MW e with 25 years of operation and Embalse NPP is a pressure tube type CANDU-600 reactor of 640 MW e. Atucha II, a third plant of 600 MW e of the pressure vessel type similar to Atucha I, is being constructed. NASA (Nucleoelectrica Argentina S.A.) currently operates both nuclear power plants. The National Atomic Energy Commission (Comision Nacional de Energia Atomica - CNEA) provides operational support to the plants, including research and development assistance, and actual technical services and maintenance work in different areas. The Chemistry Department, formerly the Reactor Chemistry Department has carried out project and support activities to the plants during the past 20 years. The aim of this work is to describe the present organization and the activities in reactor chemistry of the Chemistry ...
1999-10-15
Multi-unit Inertial Fusion Energy (IFE) plants producing hydrogen fuel
International Nuclear Information System (INIS)
A quantitative energy pathway comparison is made between a modern oil refinery and genetic fusion hydrogen plant supporting hybrid-electric cars powered by gasoline and hydrogen-optimized internal combustion engines, respectively, both meeting President Clinton's goal for advanced car goal of 80 mpg gasoline equivalent. The comparison shows that a fusion electric plant producing hydrogen by water electrolysis at 80% efficiency must have an electric capacity of 10 GWe to support as many hydrogen-powered hybrid cars as one modern 200,000 bbl/day-capacity oil refinery could support in gasoline-powered hybrid cars. A 10 GWe fusion electric plant capital cost is limited to 12.5 B$ to produce electricity at 2.3 cents/kWehr, and hydrogen production by electrolysis at 8 $/GJ, for equal consumer fuel cost per passenger mile as in the oil-gasoline-hybrid pathway.
1994-06-20
Fly on the wings of the sun - a study of solar-powered aircraft
Energy Technology Data Exchange (ETDEWEB)
Solar High Altitude Powered Platform (Solar HAPP) aircraft are unmanned remote sensing vehicles designed for cruises lasting up to one year at 20-km altitude, while carrying up to 250 pounds of cameras and electrooptic sensors in an underslung payload pod. It is anticipated that real time IR and UV images of earth features may be more inexpensively and accurately obtained by this means than by the conventional geosynchronous earth resources satellites. Solar HAPPs, with wing spans of over 300 ft and weights of only 2000 lb, require ultralight composite structures with external wire bracing. Solar cells will cover both sides of the vertical wing stabilizers and wing tips, which hinge up in daytime to capture the maximum amount of sunlight. A 15-hp electric propulsion unit drives a low-rpm, large diameter propeller; power will be derived from the solar cells diurnally, and from hydrogen-oxygen fuel cells nocturnally. The fuel gases will be ...
1985-06-01
Development of CANDU Void Reactivity Uncertainty Evaluation Methodology
International Nuclear Information System (INIS)
One of inherent characteristics of CANDU reactor is positive void reactivity in contrast to other pressurized light water reactors. During the large break loss of coolant accident, power pulse will be occurred during short time of early phase of accident due to positive void reactivity. However the duration of this power pulse is short, energy due to power pulse would be accumulated in the cladding material and will affect the peak cladding temperature or number of failed fuel elements. Recently, Canadian Nuclear Safety Commission (CNSC) indicated that the amount of void reactivity might be larger than the assumed values in safety analysis and this indication was based on the experimental data from ZED-2 facility. Based on that, the estimation of uncertainties due to the void reactivity during LBLOCA is the most important issue for CANDU safety analysis. In this study, a framework of uncertainty ...
2010-10-01
Method for predicting diffusion of discharged warm water in the regions of coastal sea
International Nuclear Information System (INIS)
The present situation of the researches that have been made for predicting the process and range of diffusion of warm drain is reviewed. This review is divided into eight sections. The first section deals with the present situation of warm drain from power plants. For the establishment of drainage standard, there are many difficult problems to be solved because water temperature differs in its nature from other regulation items. In the second section, the process of diffusion and cooling of warm drain is explained. The third section deals with the diffusion characteristics of warm drain in Japanese coastal sea due to water temperature. Two types of diffusion are known. One is dominant irregular current, and the other is periodical reciprocating stream. The fourth section deals with the methods of prediction of diffusion. Research methods and simulation models are described. The fifth section deals with the prediction with ...
1975-01-01
Feasibility of /sup 252/Cf source driven neutron noise measurements in water moderated reactors
Energy Technology Data Exchange (ETDEWEB)
Previous experiments in fast critical assemblies demonstrated a method of determining reactivity from power spectral density measurements with /sup 252/Cf. This method determines reactivity from properties of the reactor only at the subcritical state of interest, thus it does not require a calibration near delayed criticality. The interpretation of the measured data to obtain reactivity does not require knowledge of the relative or absolute values of the source intensity, knowledge of the detection efficiencies, or knowledge of the detection instrumentation frequency responses. An experiment was performed at the Pool Critical Assembly to evaluate the possibility of /sup 252/Cf source driven neutron noise spectral density measurements in light water moderated reactors. This experiment showed that using commercially available detectors, such measurements can be performed in a reasonable time, that is, the measurement of the quantity of interest ...
1980-01-01
Energy Technology Data Exchange (ETDEWEB)
Stabilized austenitic steels can suffer intercrystalline stress corrosion cracking under BWR water conditions. This experience of the last three years, which is important for German nuclear power station technology, has resulted from the discovery of cracks, which were detected in pipework made from titanium-stabilized 1.4541 charged with hot reactor water in six boiling water reactors and in core components made from niobium-stabilized 1.4550 of one BWR plant. Remedies to the pipework have been found by applying optimized materials and fabrication procedures and also by improving water chemistry conditions. (orig.) [Deutsch] Stabilisierte austenitische Staehle koennen unter SWR-Reaktorwasser-Bedingungen interkristalline Spannungsrisskorrosion (IKSpRK) erleiden. Diese fuer die deutsche Kernkraftwerkstechnik bedeutsame Erfahrung der letzten drei Jahre ergab sich aus Rissbefunden, die ...
1996-10-01
Energy Technology Data Exchange (ETDEWEB)
Hydrogen injection into the reactor water has been applied to many BWR power stations. Since hydrogen injected accelerates recombination of oxidant generated by water radiolysis, oxidant concentration, such as dissolved oxygen concentration in reactor water can be reduced. As the result of the reduction of oxidant concentration, Electrochemical Corrosion Potential (ECP) at the surface of structural material can be lowered. Lowered ECP moderates Stress Corrosion Cracking (SCC) sensitivity of structural materials, such as stainless steels. As usual, hydrogen injection system begins to work after the plant start-up is finished, when the condition of normal operation is established. Accordingly, Hydrogen Water Chemistry (HWC) does not cover all the period of plant operation. As far as SCC crack growth is considered, loss of HWC during plant start-up does not result in significant crack ...
2004-07-01
Enhanced spectral discrimination through the exploitation of interface effects in photon dose data
International Nuclear Information System (INIS)
The convolution/superposition algorithm for computing dose from photon beams in radiation therapy planning requires knowledge of the energy spectrum. The algorithm can compute the dose for a polyenergetic beam as the weighted sum of the individual dose contributions from monoenergetic beams. In this study we exploit interface effects apparent in the dose distributions to discriminate among spectra of high energy photon beams. We have studied the sensitivity of the depth dose distribution to the energy components using a hypothetical beam for various field sizes and depths in water and water-lung-water media. Six theoretical spectra were simulated. We compared depth dose data from these spectra using three quantitative measures which are inherently free of normalization ambiguities: for homogeneous water, the ratio D_2_0/D_1_0 and a logarithmic derivative in the buildup region LD_b_u_i_l_d_-_u_p and for inhomogeneous ...
2004-02-01
Low power cross-flow atmospheric pressure Ar + He plasma jet
International Nuclear Information System (INIS)
A cross-flow atmospheric plasma jet with distilled water or analyte solution nebulization has been investigated. The plasma gas flows perpendicularly to the RF powered electrode (11.21 MHz) and a grounded electrode was added for plasma stabilization. The working parameters of the plasma generator can be controlled in order to maximize either the plasma power (75 W) or the voltage on the RF powered electrode (plasma power, 40 W). The plasma gas, pure argon (0.4 l min-1) or a mixture of argon (0.3-0.4 l min-1) and helium (0-0.2 l min-1), was also used for liquid nebulization. Optical emission of the plasma, collected in the normal viewing mode, was used for plasma diagnostics and for evaluating its excitation capabilities. The influence of helium content in the mixed-gas plasma on the plasma characteristics and on the emission axial profiles of the plasma gas constituents and of the ...
2010-04-01
International Nuclear Information System (INIS)
Liquid Zone Control (LZC) System is a 'first-of-its-kind' reactivity control device, designed and implemented at TAPP-3 and 4. The system provides zonal and bulk power control. The system consists of fourteen Zone Control Compartments (ZCCs) containing demineralised light water as neutron absorber. Reactivity control is achieved by varying the level of water in the compartments bi-directionally. Six in-core zircaloy assemblies, housing the fourteen ZCCs and an elaborate process system constitute the LZC system. Measurement of water levels in the ZCCs is done using helium bubbler method. Reliability of ZCC water level measurement is of paramount importance. Commissioning and operating the new system trouble free was a challenge, considering the complex nature of the system. While commissioning the system, level measurement of one of the ZCCs (ZCC - 1) was found erratic and ...
2006-11-13
Vascular plants of the Hanford Site
Energy Technology Data Exchange (ETDEWEB)
An updated listing of the vascular plants of the Hanford Site is provided, along with discussions of how humans may interact with local plants and have influenced the regional flora. Based on examinations of herbarium collections at the Westinghouse Hanford Company, Pacific Northwest Laboratory, Washington State University, and Brigham Young University, 590 vascular plant species have been identified on or near the Hanford Site. This is more than twice the number of species on previously published lists of Hanford Site vascular plants. A review of the plant species that are currently listed as endangered, threatened, sensitive, or otherwise of concern to the Washington State Natural Heritage Program and the Federal Fish and Wildlife Service is included. Color photographs of selected species are included to aid identification. Lists are provided of the Hanford Site plant species that could be used as food and medicinal sources and of those ...
1992-07-01
Summary of comments received from workshops on radiological criteria for decommissioning
Energy Technology Data Exchange (ETDEWEB)
The Nuclear Regulatory Commission (NRC) is conducting an enhanced participatory rulemaking to establish radiological criteria for site cleanup and decommissioning of NRC-licensed facilities. Open public meetings were held during 1993 in Chicago, IL, San Francisco, CA, Boston, MA, Dallas, TX, Philadelphia, PA, Atlanta, GA, and Washington, DC. Interested parties were invited to provide input on the rulemaking issues before the NRC staff develops a draft proposed rule. This report summarizes 3,635 comments categorized from transcripts of the seven workshops and 1,677 comments from 100 NRC docketed letters from individuals and organizations. No analysis or response to the comments is included. The comments reflect a broad spectrum of viewpoints on the issues related to radiological criteria for site cleanup and decommissioning. The NRC also held public meetings on the scope of the Generic Environmental Impact Statement (GEIS) during July 1993. The GEIS meetings were ...
1994-01-01
Sludge stabilization at the Plutonium Finishing Plant, Hanford Site, Richland, Washington
Energy Technology Data Exchange (ETDEWEB)
This Environmental Assessment evaluates the proposed action to operate two laboratory-size muffle furnaces in glovebox HC-21C, located in the Plutonium Finishing Plant (PFP), Hanford Site, Richland, Washington. The muffle furnaces would be used to stabilize chemically reactive sludges that contain approximately 25 kilograms (55 pounds) of plutonium by heating to approximately 500 to 1000{degrees}C (900 to 1800{degrees}F). The resulting stable powder, mostly plutonium oxide with impurities, would be stored in the PFP vaults. The presence of chemically reactive plutonium-bearing sludges in the process gloveboxes poses a risk to workers from radiation exposure and limits the availability of storage space for future plant cleanup. Therefore, there is a need to stabilize the material into a form suitable for long-term storage. This proposed action would be an interim action, which would take place prior to completion of an Environmental Impact Statement for the PFP ...
1994-10-01
Registration of Hanford Site Class V underground injection wells
Energy Technology Data Exchange (ETDEWEB)
This document was requested by the Washington State Department of Ecology. Based on the State Underground Injection Control Program, as described in the Washington Administrative Code, French drains and reverse wells are being registered as Class V wells. Information on out-of-service French drains, out-of-service reverse wells, and out-of-service cribs that are deeper than their largest surface dimension is also provided. The data for this submittal were taken from the Waste Information Database System (WIDS) and the Hanford Environmental Compliance Record (HECR) database. The current definition used in WIDS for an ''inactive facility'' is one that either no longer receives waste or plans to in the future. The facilities listed in WIDS as inactive have all been listed as ''out-of-service.'' Information concerning the deactivation method for a facility is included when such ...
1988-05-01
The major purpose of the work described in this report was to use diffusion modeling techniques to calculate the impact on ambient air quality of SO2 emissions from the ASARCO copper smelter in Tacoma, Washington for the existing smelter configuration (51-percent constant emissions control) and for 20 alternative smelter configurations with varying degrees of constant emissions control. The accuracy of the modeling techniques was established by the close correspondence obtained between calculated and observed short-term ground-level SO2 concentrations for 20 selected historical cases, when high hourly SO2 concentrations were measured in the area surrounding the smelter, as well as by the close agreement between calculated and observed annual average concentrations for 1972. The results of the model calculations show that the maximum allowable constant SO2 emission rate consistent with maintaining the Washington Department of Ecology (DOE) and ...
1976-07-01
An aerial radiological survey of the Hanford Site and surrounding area, Richland, Washington
International Nuclear Information System (INIS)
An aerial radiological survey was conducted over the Department of Energy's Hanford Site near Richland, Washington, during the period 5 July through 26 August 1988. The survey was expanded, and additional flights were conducted to the east of the site and along the banks of the Columbia River down to McNary Dam near Umatilla. The survey was flown at altitude of 61 meters (200 feet) by a helicopter containing 17 liters (eight 2 in. x 4 in. x 16 in.) of sodium iodide detectors. Gamma ray data were collected over the survey area by flying north-south lines spaced 122 meters (400 feet) apart. The processed data indicated that detected radioisotopes and their associated gamma ray exposure rates were generally consistent with those expected from normal background emitters and man-made fission/activation products resulting from activities at the site. External exposure rates were generally 10 microroentgens per hour (#mu#R/h) with some operating areas over 1000 #mu#R/h. ...
1990-09-16
Aerodynamic design of the George Washington University solar car Sunforce 1
Energy Technology Data Exchange (ETDEWEB)
Aerodynamics play a critical role in the success of a competitive solar vehicle. In particular, the topics addressed in this paper are minimizing the drag forces acting on the car surface while providing an effective angle of solar exposure, ventilation, manoeuvring stability, maintenance accessibility, and component `functional duality`, while simultaneously maintaining stringent racing regulations. Starting with a conceptual design, modifications were analysed through a commercial, computational fluid dynamics (CFD) package in order to evaluate drag and lift characteristics. By visualizing wind tunnel flow as a means of support of the coded model, the computational design has been validated. Although the design of the George Washington University (GWU) solar car `Sunforce 1` was geared towards the November 1993 World Solar Challenge held in Australia, results of the fourth place finish in the US Sunrace `93 were used to demonstrate the effectiveness of this ...
1997-05-01
A College Guide to Disabled Student Services in Washington State.
Prepared by volunteers representing a wide range of interests and experience and including students with disabilities, this guide provides basic information about support services available to students with disabilities at public and private postsecondary education institutions in the State of Washington. The guide may also serve as a resource for family members, school counselors and others who assist students in furthering their education. The first section presents general information, discussing students' rights to appropriate education, giving basic rules for managing the transition to college life, charting effects of functional limitations in the academic setting, and providing a planning checklist for new students. Institutional profiles are presented in the second section, covering vocational-technical institutes (5), community colleges (27), and 4-year colleges and universities (16). Information is included on contact person, address, telephone, ...
1986-08-01
Water Quality Criteria | Water Quality Criteria | US EPA
for? Learn the Issues Science & Technology Laws & Regulations About EPA Contact Us Water: Water Quality Criteria You are here: Water Science & Technology Surface Water Standards &...
2011-08-28
Third RAAN conference: RAAN as Support of Nuclear Power
International Nuclear Information System (INIS)
The proceedings of the third RAAN conference, titled 'RAAN as Support of Nuclear Power', held in Drobeta Turnu-Severin, Romania on 6-7 Nov 2003, are structured on three sections covering the following issues: - Section 1. Energy and Environment (19 papers); - Section 2. Isotopic products (3 papers); - Section 3. Prospects of Nuclear Power development in Romania (17 papers). Nuclear power in Romania was initiated on the basis of CANDU reactor type technology, an option found able to fulfill the requirements for a sustainable economic development, to support the electric energy demand of the country and to ensure the population and environment protection. The construction of the Cernavoda NPP was heavily based on the Romanian industry participation and basic and applied nuclear research national resources. The experience acquired from Cernavoda NPP Unit 1 will be fruitfully used in construction of the Units 2-5 to be built. ...
2004-11-06
Performance of SPNDs used in control and safety systems
International Nuclear Information System (INIS)
Large sized reactor such as 540 MWe Pressurised Heavy Water Reactor (PHWR) requires continuous in core monitoring of local flux in order to provide effective control and protection. About 198 self powered neutron detectors (SPNDs) of the straight individually replaceable type are distributed in the reactor core. For purposes of reactor regulation, 42 prompt responding cobalt SPNDs called zone control detectors (ZCDs) are housed in vertical flux units (VFUs) and these are uniformly distributed in 14 power zones. The in core detectors used for spatial control by ZCCs do not accurately represent average zone power as they sense the flux over a small volume. Flux mapping system (FMS) comprising of 102 vanadium SPNDs in 26 VFUs, provide accurate measure of neutron flux, even though they have slow response to change in neutron flux levels. For reactor protection system-1 (RPS-1), 36 cobalt SPNDs are placed in ...
2006-11-13
Large turbine, central power generation on offshore production facilities
Energy Technology Data Exchange (ETDEWEB)
A case study of a hypothetical offshore production fixed leg platform facility is presented. The purpose of the case study is to demonstrate the advantages offered by modern, fuel efficient large gas turbines in central power generation service for offshore production. The case study was presented using the Rolls- Royce RB211 large gas turbine with facility production of approximately 240,000 BPD of oil and 540 MMSCFD of associated gas. The gas was subjected to three stages of separation for removal of hydrocarbon liquids and water. The liquids, natural gas, and crude oil were exported from the production platform to an onshore receiving terminal. Gas compression is the service that requires the greatest amount of power for any given production facility. For this case study, gas compression represented approximately 70 per cent of the power load with the remainder represented by the liquid export pumps ...
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
This thesis surveys the concepts of exergy and extends the exergy method of analysis from the standpoint of its applications to the power plant systems. After a brief historical review of exergy concepts, the general exergy equation is derived from the combined equation of First and Second Law, and it is shown that any special case of exergy equation is a simplified form of the general exergy equation. The mathematical method for the exergy analysis of a steady-state, steady-flow system, analogous to that of the First Law, is given. The exergy losses in a power plant are discussed. Then in order to examine these losses, the Second Law performance of major processes of combustion, compression, heat transfer, mixing and throttling have been analyzed analytically, and the exergy efficiencies are defined that accurately assess the thermodynamic performance of the corresponding processes. The methods for computation of exergy loss and exergy ...
1981-01-01
Energy storage for hybrid remote power systems
Energy Technology Data Exchange (ETDEWEB)
Energy storage can be a cost-effective component of hybrid remote power systems. Storage serves the special role of taking advantage of intermittent renewable power sources. Traditionally this role has been played by lead-acid batteries, which have high life-cycle costs and pose special disposal problems. Hydrogen or zinc-air storage technologies can reduce life-cycle costs and environmental impacts. Using projected data for advanced energy storage technologies, LLNL ran an optimization for a hypothetical Arctic community with a reasonable wind resource (average wind speed 8 m/s). These simulations showed the life-cycle annualized cost of the total energy system (electric plus space heating) might be reduced by nearly 40% simply by adding wind power to the diesel system. An additional 20 to 40% of the wind-diesel cost might be saved by adding hydrogen storage or zinc-air fuel cells to the system. Hydrogen produced by ...
1998-03-01
Energy Technology Data Exchange (ETDEWEB)
While underground power transmission lines have become to use CV cables as the mainstream, existing facilities still use OF cables. Factors of OF cable deterioration include heat cycles during operation and surge intrusion. As a method to diagnose this deterioration in insulation, characteristics tests are performed by collecting insulation oil in a cable connection box. The insulation oil collection work has been done conventionally with the power line stopped to prevent danger from induction voltage. A power uninterruptible oil collection tool was developed recently. The tool consists mainly of an insulator made of epoxy resin, wherein a connection box connector is rotated and loosened by operating an insulating operation rod, with the structure not contacted directly with metallic sheath, so that insulation oil can go through the oil collecting tool and gets collected. Discussions were given on the tool to be capable of ...
1999-02-10
Washington: a guide to geothermal energy development
Energy Technology Data Exchange (ETDEWEB)
A brief overview is given of the geological characteristics of each region of the state as they relate to potential geothermal development. Those exploration methods which can lead to the siting of a deep exploration well are described. Requirements and techniques needed for drilling deeper higher temperature exploration and production wells are presented. Electrical generation, direct utilization, and indirect utilization are reviewed. Economic factors of direct use projects are presented. A general guide to the regulatory framework affecting geothermal energy development is provided. The general steps necessary to gain access to explore, develop, distribute, and use geothermal resources are outlined. (MHR)
1980-01-01
United States Department of Energy breeder reactor staff training domestic program
Energy Technology Data Exchange (ETDEWEB)
Two US DOE projects in the Pacific Northwest offer unique on-the-scene training opportunities at sodium-cooled fast-reactor plants: the Fast Flux Test Facility (FFTF) near Richland, Washington, which has operated successfully in a wide range of irradiation test programs since 1980; and the Experimental Breeder Reactor II (EBR-II) near Idaho Falls, Idaho, which has been in operation for approximately 20 years. Training programs have been especially designed to take advantage of this plant experience. Available courses are described.
1984-01-01
PFP dangerous waste training plan
This document establishes the minimum training requirements for the Plutonium Finishing Plant (PFP) personnel who are responsible for management of dangerous waste. The training plan outlines training requirements for handling of solid dangerous waste during generator accumulation and liquid dangerous waste during treatment and storage operations. The implementation of this training plan will ensure the PFP facility compliance with the training plan requirements of Dangerous Waste Regulation. Chapter 173-303-330. Washington Administrative Code (WAC). The requirements for such compliance is described in Section 11.0 of WHC-CM-7-5 Environmental Compliance Manual.
1996-01-01
Prepared and presented by Professor Raj Jain at Washington University in St. Louis, this series of presentations is designed to introduce computer science students to the fundamentals of network security. Visitors have the option of choosing to download or view the presentations with audio, as individual slides only, or as a single PDF document. Topics here include: security requirements, public key encryption, digital signatures, and confidentiality. This is an excellent site for educators to use in the classroom or as a supplementary resource to introduce students to computer network security. Students may also wish to view or download the presentations to learn the basic concepts of network security.
2008-01-30
Maintenance implementation plan for T Plant. Revision 2
Energy Technology Data Exchange (ETDEWEB)
This document is a Maintenance Implementation Plan (MIP) for the T Plant Facility complex located in the 200 West Area of the Hanford Reservation in Washington state. This plan has been developed to provide a disciplined approach to maintenance functions and to describe how the T Plant facility will implement and comply with the regulations according to US DOE order 4330.4B, entitled Maintenance Management Program, Chapter 2.0 {open_quotes}Nuclear Facilities{close_quotes}. Physical structures, systems, processes, as well as all associated equipment specifically assigned to these groups are included in the MIP.
1995-05-01
MTS 94: Challenges and opportunities in the marine environment
Energy Technology Data Exchange (ETDEWEB)
The Marine Technology Society 1994 conference was held in Washington, D.C., September 7-9, 1994. Titled Challenges and Opportunities in the Marine Environment, the conference offered a wide variety of presentations. State-of-the-art technology, government policies and regulations, and environmental concerns were addressed. Offshore mining, coastal zone management, marine engineering, oceanographic research, educational issues, and global climate change were also well represented in the presentations. The conference proceedings are organized around the daily sessions and roughly 70% of the papers are included.
1994-01-01
Information on Hanford site cribs and septic systems
Energy Technology Data Exchange (ETDEWEB)
This document provides information on septic systems with a design capacity of greater than 14,500 gal/d and cribs submitted as requested by the Washington State Department of Ecology. Data for this submittal were taken from the Waste Information Database System (WIDS) and the Hanford Environmental Compliance Record (HECR) database. The current definition used in WIDS for an ''inactive facility'' is one that either no longer receives waste or plans to in the future. Information concerning the deactivation method for a facility is included when such information is available.
1988-05-01
INEEL Advanced Radiotherapy Research Program Annual Report 2001
Energy Technology Data Exchange (ETDEWEB)
This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.
2002-04-01
INEEL Advanced Radiotherapy Research Program Annual Report 2001
Energy Technology Data Exchange (ETDEWEB)
This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.
2002-04-30
Energy Technology Data Exchange (ETDEWEB)
This is the ninth quarterly report as required by the Hanford Federal Facility Agreement and Consent Order (Ecology et al. 1990), also known as the Tri-Party Agreement, established between the US Department of Energy (DOE), the US Environmental Protection Agency (EPA), and the Washington State Department of Ecology (Ecology). The Tri-Party Agreement sets the plan and schedule for achieving regulatory compliance and cleanup of waste sites at the Hanford Site. This report covers progress for the quarter that ended June 30, 1991. A total of 87 milestones have been completed to date. 39 refs., 1 fig.
1991-08-01
Environmental sciences and applications. Volume 4. Strategy for the ozone layer
Energy Technology Data Exchange (ETDEWEB)
A synthesis of papers based on the United Nations Environment Programme meeting on the ozone layer, Washington DC, this book contains valuable information on ongoing and planned activities concerned with stratospheric ozone problems, and presents the recommendations for further action resulting from the meeting. Possible changes in the characteristics of the ozone layer are discussed, together with the environmental, ecological, climatic, economic, and health implications of stratospheric ozone depletion. A comprehensive survey of current research in five European countries, the USA, Canada, and Australia is included and the volume is concluded by the UNEP report of the meeting and a world plan of action.
1980-01-01
Computer control of fuel handling activities at FFTF
International Nuclear Information System (INIS)
The Fast Flux Test Facility near Richland, Washington, utilizes computer control for reactor refueling and other related core component handling and processing tasks. The computer controlled tasks described in this paper include core component transfers within the reactor vessel, core component transfers into and out of the reactor vessel, remote duct measurements of irradiated core components, remote duct cutting, and finally, transferring irradiated components out of the reactor containment building for off-site shipments or to long term storage. 3 refs., 16 figs.
1985-09-08
Bechtel Hanford Inc. Network Security Plan for the EnvironmentalRestoration Contract
'As part of the Computer Protection Plan, this Network Security Plan identifies the specific security measures used to protect Bechtel Hanford, Inc.'s (BHI's) enterprise network. The network consists of the communication infrastructure and information systems used by BHI to perform work related to the Environmental Restoration Contract (ERC) at the Hanford Site. It provides electronic communication between the ERC-leased facilities in Richland, Washington, and facilities located on the Hanford Site. Network gateways to other site and offsite networks provide electronic communication with the remainder of the Hanford community.'
1999-06-30
Energy Technology Data Exchange (ETDEWEB)
Sufficient discussion of the elements of the leasing and permitting programs is included to place the information developed in proper context. A table and process flow diagram developed previously which outline the steps in the non-competitive leasing process, is reprinted. Computer printout profiles are presented on 195 identifiable areas in the following states: Arizona, California, Colorado, Idaho, Montana, Nevada, New Mexico, Oregon, Utah, Washington, and Wyoming. Sufficient information on the boundaries of these areas is contained in the report to permit identification of their general location on any map of the appropriate state which shows township and range locations.
1982-02-01
Acceptance test report for the Westinghouse 100 ton hydraulic trailer
Energy Technology Data Exchange (ETDEWEB)
The SY-101 Equipment Removal System 100 Ton Hydraulic Trailer was designed and built by KAMP Systems, Inc. Performance of the Acceptance Test Procedure at KAMP`s facility in Ontario, California (termed Phase 1 in this report) was interrupted by discrepancies noted with the main hydraulic cylinder. The main cylinder was removed and sent to REMCO for repair while the trailer was sent to Lampson`s facility in Pasco, Washington. The Acceptance Test Procedure was modified and performance resumed at Lampson (termed Phase 2 in this report) after receipt of the repaired cylinder. At the successful conclusion of Phase 2 testing the trailer was accepted as meeting all the performance criteria specified.
1995-03-06
Some applications of nuclear techniques in hydrology and water pollution studies in Norway
International Nuclear Information System (INIS)
... hydrology norway water pollution pollution scandinavia surface waters
Energy Technology Data Exchange (ETDEWEB)
Oil, in various forms, has been used for thousands of years and has even been recommended as a medicinal product. Starting in the mid-19. century, however, mineral oil production became an economic, political, social and scientific gold mine. Subterranean and offshore drilling rigs have created colossal fortunes among multinationals and made certain nations extremely wealthy. Starting in the 1920's, oil companies began to explore the possibilities of undersea drilling, but it was only in 1947 that the first offshore drilling rig was set up. With three-quarters of the planet covered by water, it was inevitable that oil companies would turn to offshore drilling - especially as sub-sea oil fields may cover as much as 84 million square kilometres. Drilling rigs now go deeper than ever and are able to operate in up to 3000 meters water depth. This paper will present the technical merits of two similar all-electric drill-ships ...
2000-07-01
Development of next-generation light water reactor in Japan
International Nuclear Information System (INIS)
In Japan, the development of next-generation Light Water Reactor has been launched since April 2008. The development program will be completed in 2015. The purpose of development is to cope with the replacement for existing nuclear power plants after 2030 in Japan and the expanding demand for nuclear power in the world; 'Nuclear Renaissance.' The reactor also aims to be global standard at around 2030. The requirements for global standard and domestic users have been investigated through the feasibility study of past 2 years, 2006-2007, and six innovative features or 'Core-Concepts' were established as follows. A) Reactor core system with uranium enrichment above 5% for significant decrease of spent fuel discharge and prominent higher availability B) Long-life materials and innovative water chemistry technologies for 80 years plant lifetime and significant reduction of occupational dose C) Seismic ...
2009-10-27
International Nuclear Information System (INIS)
The first Advanced Boiling Water Reactor (ABWR) started commercial operation as Tokyo Electric Power Company's (TEPCO) Kashiwazaki-Kariwa Nuclear Power Station Unit No.6 (K-6) in November 1996 and its sister Unit No.7 (K-7) in July 1997. The ABWR was developed to achieve higher reliability and safety margin while improving overall operability and economics. To achieve these goals, the optimal Boiling Water Reactor (BWR) technologies had been studied, tested and were finally adopted into the ABWR design. These technologies were called 'First of a Kind' and include the Reactor Internal Pump (RIP), Fine Motion Control Rod Drive (FMCRD), Reinforced Concrete Containment Vessel (RCCV), and integrated digital Instrumentation and Control System (I and C). Intensive development study, confirmation tests and verification tests were conducted by the plant equipment suppliers, electric utilities, and government ...
1999-12-01
Energy Technology Data Exchange (ETDEWEB)
The objective of this project was to develop new photocatalytic or other innovative process chemistry for the treatment of pink water and related contaminated water.
1996-10-01
Energy Technology Data Exchange (ETDEWEB)
Within the Annual Conference 2009 of the VGB PowerTech e.V. (Essen, Federal Republic of Germany) from 23rd to 25th May, 2009, in Lyon (France) the following lectures were held: (1) Electricity demand, consequences of the financial and economic crisis - Current overview 2020 for the EU-27 (Hans ten Berge); (2) Status and perspectives of the electricity generation mix in France (Bernard Dupraz); (3) European electricity grid - status and perspective (Dominique Maillard); (4) Technologies and acceptance in the European energy market (Gordon MacKerran); (5) EPR construction in Finland, China, France, (Claude Jaouen); (6) EPR Flamanville 3: A project on the path towards nuclear revival (Jacques Alary); (7) Worldwide nuclear Revival and acceptance (Luc Geraets); (8) An overview on the status of final disposal of radioactive wastes worldwide (Piet Zuidema); (9) Who needs pumped storage plants? PSP are partner to grid stability and renewable energies (Hans-Christoph ...
2009-07-01
International Nuclear Information System (INIS)
Within the Annual Conference 2009 of the VGB PowerTech e.V. (Essen, Federal Republic of Germany) from 23rd to 25th May, 2009, in Lyon (France) the following lectures were held: (1) Electricity demand, consequences of the financial and economic crisis - Current overview 2020 for the EU-27 (Hans ten Berge); (2) Status and perspectives of the electricity generation mix in France (Bernard Dupraz); (3) European electricity grid - status and perspective (Dominique Maillard); (4) Technologies and acceptance in the European energy market (Gordon MacKerran); (5) EPR construction in Finland, China, France, (Claude Jaouen); (6) EPR Flamanville 3: A project on the path towards nuclear revival (Jacques Alary); (7) Worldwide nuclear Revival and acceptance (Luc Geraets); (8) An overview on the status of final disposal of radioactive wastes worldwide (Piet Zuidema); (9) Who needs pumped storage plants? PSP are partner to grid stability and renewable energies (Hans-Christoph ...
2009-09-23
Energy Technology Data Exchange (ETDEWEB)
This proceedings volume comprises 17 papers on the following subjects: Methane hydrates, compounds of gas and water; Compressed air stroage gas turbine power plants / Scheduled application for load levelling between varying wind power production and power demand; Modern pumped storage power stations in the GW range - the PSW Goldisthal example; Lead batteries - new developments and future applications; Alkaline battery systems for hybrid electric road vehicles; Lighium systems and their applications; Zinc/air cells; Hydrogen storage - metal hydride storage, compressed gas storage, LNG storage; Carbon nanofibres for hydrogen storage; Double-layer condensers - technology, cost, perslpectives; Supercondensers in motor vehicles; Superconducting magnetic energy stores; Flywheel storage - status report; Decentralized energy storage in the European integrated supply grid - the EU project ...
2002-07-01
Energy Technology Data Exchange (ETDEWEB)
Analyzing various SBLOCA with high pressure safety injection (HPSI) at VVER-440/213, we met a surprising phenomenon - a 'natural' circulation post SG heat transfer reversal. This is not usual, because normal natural circulation (NC) in primary circuit is connected with positive heat transfer at SG. If there is reverse heat transfer at SG (as soon as the break enthalpy outflow is sufficient for removal of reactor decay heat), it should obstruct any natural circulation. The question was, what is the driving force of this 'non-standard natural circulation'. After all we revealed that force - it is the density difference between the colder water in reactor downcomer (cold water from HPSI) and warmer water in inner reactor (lower plenum, core, upper plenum). This phenomenon could be confusing for operating personal, because there would be an opposite temperature difference at the loop than by ...
2001-07-01
International Nuclear Information System (INIS)
Analyzing various SBLOCA with high pressure safety injection (HPSI) at VVER-440/213, we met a surprising phenomenon - a 'natural' circulation post SG heat transfer reversal. This is not usual, because normal natural circulation (NC) in primary circuit is connected with positive heat transfer at SG. If there is reverse heat transfer at SG (as soon as the break enthalpy outflow is sufficient for removal of reactor decay heat), it should obstruct any natural circulation. The question was, what is the driving force of this 'non-standard natural circulation'. After all we revealed that force - it is the density difference between the colder water in reactor downcomer (cold water from HPSI) and warmer water in inner reactor (lower plenum, core, upper plenum). This phenomenon could be confusing for operating personal, because there would be an opposite temperature difference at the loop than by normal natural circulation (under ...
2001-03-20
The effect of a metal hip prosthesis on the radiation dose in therapeutic photon beam irradiations
International Nuclear Information System (INIS)
Prostate and cervical cancer patients are often treated with external X-ray beams of bi-lateral incidence. Such treatment may incur some dose effect that cannot be predicted precisely in commercial treatment planning systems (TPS) for patients having undergone total hip replacement. This study performs a Monte Carlo (MC) simulation and an analytical calculation (convolution superposition algorithm which is implemented in ADAC TPS) of a 6 MV, 5x5 cm"2 X-ray beam incident into water with the existence of hip prosthesis, e.g. Ti6Al4V and CoCrMo alloy. The results indicate that ADAC TPS cannot precisely account for the scatter and backscatter radiation that a metal hip prosthesis causes. For percent depth dose (PDD) curves, the maximum underdosage of ADAC TPS up to 5 mm above the interface between dense material and water is 5%, 20% and 27% for PDD_B_o_n_e, PDD_T_i and PDD_C_o, respectively. The dose re-buildup, which occurs behind the hip region, ...
2002-07-01
Environmental-impact assessment of dams and reservoir projects (review and a case study)
International Nuclear Information System (INIS)
Dams and reservoirs are among one of the most sensitive of all development Project, in terms of pervasiveness of their influence in altering the environmental conditions and resources. In the present study, major dams and reservoir projects are reviewed, from the environmental point of view. Dams and Reservoir projects bring about major changes in the immediate environment, thus affecting public health, settlements, farmlands, roads and historical sites. Impacts on human population and wildlife may be profound. Tropical diseases, involving fresh-water hosts or vectors in their transmission, are often common around new reservoirs. Large lakes create limnological changes, excessive evaporation, seepage, disturbance in water-table and increased tendencies of landslides and earthquakes. Micro climatic changes are possible, such as fog formation, increased cloudiness and modified rainfall-patterns. Retention of sediment results in silting up of ...
CFD simulation of steam generator tube rupture thermal-hydraulics
Energy Technology Data Exchange (ETDEWEB)
Several steam generator tube rupture accidents have occurred at plants in the past. In this paper the Computational Multi-Fluid Dynamics (CMFD) investigation of the horizontal steam generator thermal-hydraulics during the tube rupture accident is performed. A guillotine of a steam generator U-tube is assumed with choked flow from the primary to the secondary side of the steam generator. We have computed water and steam velocity fields, steam volume fraction distribution on the steam generator secondary (shell) side, as well as the swell level increase. The simulation results are a support to the safety analyses of the steam generator tube rupture accident. Numerical simulation is performed with the multidimensional multi-fluid modelling approach. The two-phase flow around steam generator tubes in the bundle is modelled by the porous media approach. Interfacial mass, momentum and energy transfer are modelled with the closure laws. The governing equations are solved ...
2004-07-01
{sup 252}Cf-source-driven frequency analysis measurements with subcritical arrays of PWR fuel pins
Energy Technology Data Exchange (ETDEWEB)
Experiments with fresh PWR fuel assemblies were performed to assess the {sup 252}Cf-source-driven frequency analysis method for measuring the subcriticality of spent fuel. The measurements at the Babcox and Wilcox Critical Experiments Facility mocked up between 17x17 fuel pins (single assembly) and a full array of 4961 fuel pins (about 17 fuel assemblies) in borated water with a fixed B concentration. For the full array, the B content of the water was varied from 1511 at delayed criticality to 4303 ppM. Measurements were done for various source-detector-fuel pin configurations; they showed high sensitivity of frequency analysis parameters to B content and fissile mass. Parameters such as auto and cross power spectral densities can be calculated directly by a more general model of the Monte Carlo code (MCNP-DSP). Calculation-measurement comparisons are presented. This model permits the validation of neutron and gamma ray ...
1996-08-01
International Nuclear Information System (INIS)
In the heat exchangers of power plants, scale deposition may occur, especially at the leading edge of contraction. The growth of scale can lead to an increase in pressure and cause oscillation of the water level. In our previous study, the dependence of flow on contraction geometry was analyzed numerically and empirically. It was shown that the contraction ratio of hydraulic diameter of the flow path contributed greatly to the difference in pressure drop and turbulent kinetic energy at the leading edge of the flow path. In this study, the effect of contraction geometry and flow rate on scale adhesion was studied in AVT chemistry at 270degC using a high-velocity scale-adhesion test loop. The differential pressure and the amount of scale deposited due to scale adhesion at the leading edge of the flow path increased more in a quatrefoil-type flow path than in drill-type flow path. The differential pressure and the amount of scale deposited also ...
1999-05-01
Sulfur and carbon cycling in a flue gas desulfurization sludge disposal site.
Products of a power plant flue gas desulfurization scrubber are discharged into a pond as sludge consisting of calcite (initial delta13C 3.2-3.8 per thousand), gypsum (initial delta34S 7.6-8.6 per thousand), and aqueous solution. Reducing conditions exist below a boundary that appears to move vertically as a function of changes in pond water level. Under reducing conditions, bacteria partially reduce aqueous sulfate to low-delta34S sulfide, consuming organic carbon and generating low-delta13C bicarbonate. Under oxidizing conditions, sulfide is converted to sulfate, leading to calcite dissolution, gypsum precipitation, and isotopic re-equilibration of remaining calcite with dissolved bicarbonate near the pond surface. The gypsum has delta34S near 6 per thousand, and calcite has delta13C as low as -1.7 per thousand; the changes from initial values correspond to predictions based on isotopic balance and reaction stoichiometry. The pond largely ...
2003-04-01
Energy Technology Data Exchange (ETDEWEB)
A hose lining process, used widely for underground service structures, such as for city gas, and water and sewerage pipes, was adopted to repair interiors of underground wire raceways, and improvements were made for power cable pipe use, including long size construction, inner diameter assurance, and flame retardation. The sealing hose as a lining material consists of a fabric layer woven by warps of polybutylene terephthalate (PBT) and wefts of combined PBT fibers and glassfibers, the fabric being coated with polyurethane resin on one side. The other side of the fabric is coated with heat hardening resin made of epoxy resin as the main ingredient and aromatic amine as the hardening agent to assure close adhesion of the sealing hose onto the pipe interior. Mimic raceways were used to verify the lining material for its abrasion coefficient, mechanical strength, wear resistance, water cut-off performance, chemical resistance, ...
1991-03-25
Program plan for development of underground hydroelectric pumped storage technology
The Underground Hydroelectric Pumped Storage (UHPS) Program Plan describes in detail the planned activities and expected accomplishments in the conduct of UHPS technology development and validation envisioned in the 1976 to 1990 time frame. This document describes the program objectives, implementation strategy, and management methodology. The concept of underground hydroelectric pumped storage is fully directed to application in the electric utility industry. This technology involves using electrical energy generated by base-load plants during off-peak load periods to drive a high-head pump/turbine which pumps water from a lower reservoir to a substantially elevated (upper) reservoir corresponding to a head of 1000 m or so. The upper reservoir is at ground level and the lower reservoir is below ground. Then, during peak-load periods, water in the upper reservoir is allowed to flow to the lower reservoir which, in turn, drives a hydraulic ...
1976-03-01
Potential for geothermal development in Southern Poland
Energy Technology Data Exchange (ETDEWEB)
This paper discusses the potential for geothermal energy use in the central part of Southern Poland, such as the availability of thermal aquifers and the techniques for putting the latter to practical use. The geological and geothermal features of the region are presented within the context of the existence of aquifers containing geothermal resources that could be used in space heating. Also discussed are the three main geological units where thermal waters are known to exist: the Carpathians, the Miechow Trough, and the Silesian-Cracow Monocline. Particularly favourable hydrogeological conditions exist in the Inner Carpathians, in the Podhale Trough, where there is already one geothermal company using geothermal energy, Geotermia Podhalanska S.A. Equally interesting from the geothermal point of view are the areas north of the Cracow-Tarnow line, where, in Mesozoic aquifers, water temperatures range from 20 to 60 {sup o}C. In this paper we ...
2004-06-01
Operating experience with solidification of radioactive waste by a thin-film evaporator
Energy Technology Data Exchange (ETDEWEB)
In the nuclear power stations of GDR the rough radioactive waste includes borat-containing evaporator bottoms and spent ion exchanger resins. For its final disposal in deep geological formations (rock salt mines) this waste has to be solidified. The experience of one year lasting operation of a steam heated thin-film evaporator (heating surface 2 m{sup 3}) for evaporator bottoms to be solidified with a solid content of 200-250 g/l are reported on. In short time such amount of water is abstracted from the rough waste that due to the borate content a hot high-viscous product passes from evaporator to waste drum and there solidifies like glass to monolith. The product quality depends on the adjustment of the flow-equilibrium in the evaporator. Boric acid is used as matrix for the radioactive residues. The residual water content of the solidified waste product was about 15-20%, the volume reduction was V{sub f}=5...6. In order ...
1990-01-01
Operating experience with solidification of radioactive waste by a thin-film evaporator
International Nuclear Information System (INIS)
In the nuclear power stations of GDR the rough radioactive waste includes borat-containing evaporator bottoms and spent ion exchanger resins. For its final disposal in deep geological formations (rock salt mines) this waste has to be solidified. The experience of one year lasting operation of a steam heated thin-film evaporator (heating surface 2 m"3) for evaporator bottoms to be solidified with a solid content of 200-250 g/l are reported on. In short time such amount of water is abstracted from the rough waste that due to the borate content a hot high-viscous product passes from evaporator to waste drum and there solidifies like glass to monolith. The product quality depends on the adjustment of the flow-equilibrium in the evaporator. Boric acid is used as matrix for the radioactive residues. The residual water content of the solidified waste product was about 15-20%, the volume reduction was V_f=5...6. In order to be sure ...
1990-06-01
Numerical Simulation and Analyses of the Loss of Feedwater Transient at the Unit 4 of Kola NPP
A three-dimensional numerical simulation of the loss-of-feed water transient at the horizontal steam generator of the Kola nuclear power plant is performed. Presented numerical results show transient change of integral steam generator parameters, such as steam generation rate, water mass inventory, outlet reactor coolant temperature, as well as detailed distribution of shell side thermal-hydraulic parameters: swell and collapsed levels, void fraction distributions, mass flux vectors, etc. Numerical results are compared with measurements at the Kola NPP. The agreement is satisfactory, while differences are close to or below the measurement uncertainties. Obtained numerical results are the first ones that give complete insight into the three-dimensional and transient horizontal steam generator thermal-hydraulics. Also, the presented results serve as benchmark tests for the assessment and further improvement of one-dimensional ...
2002-07-01
Institutt for Energiteknikk - Annual Report 1994
Energy Technology Data Exchange (ETDEWEB)
Work at Institutt for energiteknikk (IFE) comprises both nuclear and non-nuclear activities. The main nuclear program is centered on the Halden Reactor Project. In 1958, the first Halden Reactor Project Agreement was signed by organisations representing 12 European countries. During 1994 France became a full member and associate membership was established with Russia. Accordingly, 16 countries were participating in the Project by the end of the year. The objectives have evolved from being simply a demonstration of the operation of a boiling heavy-water reactor to becoming a substantial research and development programme covering the domains of human-machine interaction, fuel behaviour, materials testing, water chemistry, and instrumentation. In 1994, significant progress was achieved in all of the areas addressed by the project, including the re-instrumentation of irradiated fuel rods, fission gas release, irradiation-assisted stress corrosion ...
1995-12-01
Improvement of leaching characteristics of TOC from condensate demineralizers
International Nuclear Information System (INIS)
Recent nuclear power plants require high purity water to protect nuclear reactors or steam generators from SCC and maintain in good condition. In this connection, it is especially important to minimize sulfate, which is a corrosive chemical originated from oxidative degradation of cation exchange resins during operation. Recently, uniform particle size (UPS) strong acid cation gel resin with 14% cross-linkage, which has excellent stability against oxidization, has been applied to several condensate purification systems. For further improvement of water quality, some methods for changing the configuration of condensate demineralizer's resin bed have been examined. For example, these methods correspond to anion under layer and cation over layer. We have tested these methods by cold column tests. Furthermore, we have developed the newly anion exchange resin having higher efficiency and capacity for absorbing leachables from ...
2009-10-01
Fuzzy decision making in multiobjective long-term scheduling of hydrothermal system
Energy Technology Data Exchange (ETDEWEB)
In the paper, a fuzzy decision-making methodology is presented to decide the generation schedule of long-term hydrothermal problems with explicit recognition of statistical uncertainties in system production cost data, NO{sub x} emission data, system load demand and hydro reservoir water inflows. In deciding the optimal operation, three objectives operating cost, NO{sub x} emission and unsatisfied load demand over the whole of the planning period are simultaneously minimised. Specific technique is put forth to convert the stochastic models into their deterministic equivalents. The weighted minimax method is used to simulate the tradeoff relation between the conflicting objectives in the non-inferior domain. The fuzzy set theory is exploited to choose the best operating point over the tradeoff curve. An efficient decomposition technique is applied to reduce the complexity of the problem. In each subproblem, thermal generations are obtained by using simplified method ...
2001-01-01
Fuel assembly and reactor core
International Nuclear Information System (INIS)
In a fuel assembly having moderator rods, an axial average value of a ratio between the total of the lateral cross sectional area of a portion to be filled with moderators and the total of the lateral cross sectional area of fuel pellets is determined as greater than 0.4, a lateral cross sectional area of a portion to be filled with moderators per one moderator rod is determined as from 14 to 50cm"2 and the ratio between the total of the lateral cross sectional area of moderators and a total of the lateral cross sectional area of fuel pellets in a horizontal cross section is determined as from 2.7 to 3.4. Since the axial average value for lateral cross sectional area of a portion to be filled with moderators/lateral cross sectional area of fuel pellets is determined as #>=# 0.4, the lateral cross sectional area of moderators of moderator rods is increased, the lateral cross sectional area of a gap water region is decreased to reduce the value of local ...
1992-12-03
Fixed time and fixed point observation of environmental radioactivities in Tokyo
Energy Technology Data Exchange (ETDEWEB)
A measurement of environmental radioactivity in Tokyo was started from 1974. We have been executing fixed time and fixed point observation since 1983 in Tokyo continuously. Measurement item is rain water, airborne dust, activated sludge at sewage treatment plants and external dose rate. Measurement data from 1983 to 1995 is reported in this paper. Moreover, we have been carried out the measurement of radon concentration in air from 1988 to 1991 in different types of residental buildings. The measurement results of rain water, airborne dust, external dose rate were approximately a background level respectively except for the Chernobyl nuclear power plant accident. Radionuclides used as radiopharmaceuticals were detected in the activated sludge at every sewage treatment plant but its concentration was lower than concentration limit in Japan. From a result of radon concentration measurements, there were no place which exceeds ...
1997-03-01
Environmental tritium in the areas adjacent to Wolsong nuclear power plant
International Nuclear Information System (INIS)
The distribution of environmental tritium and the correlation coefficients between tritium concentrations in several environmental samples and the emissions of tritiated water vapor from Wolsong NPP 1 were studied. The annual mean concentrations of atmospheric HTO were in the range 1#centre dot#31-29#centre dot#2 Bq m"-"3 and the long-term atmospheric dilution factors were in the range 10"-"7-10"-"6 s m"-"3. Annual mean concentrations of tritium in ground water were in the range 19#centre dot#2-27#centre dot#9 Bq l"-"1 at N-1 and 64#centre dot#1-189 Bq l"-"1 at S-2, and were generally less than 0#centre dot#2% of MPC_w (222 kBq l"-"1). The concentrations of tritium in precipitation decreased exponentially with distance from Wolsong NPP 1, falling to current global levels at about 25 km off-site. The highest concentration of tritium in soil moisture was observed in May and June, when the relative humidity was high. The concentrations of tritium ...
1998-11-01
Energy Technology Data Exchange (ETDEWEB)
A cost study is described which compared the economics of four dry/wet cooling systems to use at the existing Raft River Geothermal Plant. The results apply only at this site and should not be generalized without due consideration of the complete geothermal cycle. These systems are: the Binary Cooling Tower, evaporative condenser, Combin-aire, and a metal fin-tube dry cooling tower with deluge augmentation. The systems were evaluated using cooled, treated geothermal fluid instead of ground or surface water in the cooling loops. All comparisons were performed on the basis of a common plant site - the Raft River 5 MWe geothermal plant in Idaho. The Binary Cooling Tower and the Combin-aire cooling system were designed assuming the use of the isobutane/water surface condenser currently installed at the Raft River Plant. The other two systems had the isobutane ducted to the evaporative condensers. Capital credit was not given to the system employing ...
1982-07-01
International Nuclear Information System (INIS)
Different concrete waste packages have been designed by Electricite de France (EDF) for the long-term storage of radioactive Low Level Waste (LLW). Their main function is to confine radionuclides from the biosphere for three hundred years in a near-surface disposal. According to the transport regulations, a Type-B package is needed for some waste like water filters. The water filters from EDF nuclear power plants are encapsulated in mortar and placed in a concrete container. Transport regulations for these containers have required the development of a methodology for safety assessment. The reference scenario of container degradation during transport considers a 9 m drop and a 800"oC fire for 30 min. First, the different chemical and physical processes involved in the containment of radionuclides are analysed. In particular, the radionuclide transport mechanisms in cement-based materials have been reviewed. Secondly, the ...
Cooling towers of power plants are used to dissipate waste heat into the atmosphere. If saline water is used for cooling, a saline aerosol known as drift is released into the atmosphere. Drift effects on vegetation are not well known. To simulate drift for a field study, cooling tower basin water was sprayed thirty separate times during a 46-day period in 1975 on Virginia pine (Pinus virginiana), flowering dogwood (Cornus florida), tulip tree (Liriodendron tulipfera), and California privet (Ligustrum ovalifolium), Norway spruce (Picea abies), and white ash (Fraxinus americana) were added in 1976 and all trees were sprayed 43 times during a 59-day period. Only dogwood leaves showed significant injury. Absence of injury on other species was probably due to the ability of their leaves to exclude, or reduce absorption of, toxic concentrations of the ions supplied.
1977-07-01
Energy Technology Data Exchange (ETDEWEB)
In order to gain a wider knowledge of corrosion phenomena in OFHC (oxygen free high conductivity) copper pipes of the stator cooling circuit of a power plant turboalternator, a research program was laid out which is based on the use of an experimental loop simulating real operating conditions as closely as possible. The samples examined were either copper foils or hollow conductors of the type that is normally used in the stator cooling system, and the circulating fluid was high purity water with controlled O/sub 2/, H/sub 2/ and C0/sub 2/ contents. Investigations were focused on the kinetics of O/sub 2/ removal through catalytic resins covered with metallic palladium (at different temperatures and pressures) and on the kinetics of CO/sub 2/ removal through mixed bed resins. Subsequently, attention was directed to the corrosion of copper (in the form of foils or hollow conductors) under different experimental conditions simulating either ...
1991-12-31
International Nuclear Information System (INIS)
Heat transfer tubes of a primary pressurized water cooled (PPWC) in the high temperature engineering test reactor (HTTR) form the reactor pressure boundary of the primary coolant, therefore are important from the viewpoint of safety. To establish inspection techniques for the heat transfer tubes of the PPWC, an automatic inspection system was developed. The system employs a bobbin coil probe, a rotating probe for eddy current testing (ECT) and a rotating probe for ultrasonic testing (UT). Nondestructive test of a half of the heat transfer tubes of the PPWC was carried out by the automatic inspection system during reactor shutdown period of the HTTR (about 55% in the maximum reactor power in this paper). The nondestructive test results showed that the maximum signal-to-noise ratio was 1.8 in ECT. Pattern and phase of Lissajous wave, which were obtained for the heat transfer tube of the PPWC, were different from those obtained for the ...
International Nuclear Information System (INIS)
Through the analysis of the relations between "3H monitoring results of sea water in West Daya Bay carried out by Guangdong Environmental Radiation Research and Monitoring Center (GERC) from 1994 to 2000 and the quantity of liquid "3H discharges made by Guangdong Nuclear Power Station (GNPS), the function has been found by fitting to describe the relation between "3H average concentrations (hereafter as to average concentration or concentration) for all sampling points at the same time and the quantity of liquid "3H discharges. "3H instantaneous concentrations or yearly average concentration in West Daya Bay can be estimated conveniently by using this function corresponding to either actual discharges or supposed discharges (the way for hydrodynamic calculation) from the GNPS's yearly "3H liquid discharge. The results have shown that the general influences both actual discharges and supposed sub-continuous discharges are almost the same and ...
2001-11-01
An analysis of PZR and related system design features for KNGR
Energy Technology Data Exchange (ETDEWEB)
The development of KNGR (Korean Next Generation Reactor) is now in progress. KAERI is developing KNGR which is a advanced active PWR (pressurized water reactor) and 1350 MW electric capacities and is by based on UCN(Ulchin) 3 and 4 nuclear power plant which is a Korean standard PWR. In this report, the PZR (pressurizer) and Related System Design Features for KNGR which include PZR volume, PPCS (pressurizer safety valve)were analyzed. First, the Design Parameters between KNGR compared to UCH 3 and 4 were compared, and second, advanced design features of KNGR compared to UCN 3 and 4 were analyzed. After the present analysis, it has been concluded that the safety margins for the PZR level and pressure of KNGR were more increased by the larger PZR volume than those of UCN 3 and 4, for PZR minimum water level at reactor/turbine trip and PZR maximum pressure at LOCV(loss of condenser vacuum) of KNGR were higher and lower, ...
1995-12-01
Advanced water purification facility; Kodo josui shori gijutsu
Energy Technology Data Exchange (ETDEWEB)
Accelerated oxidation treatment technology is introduced for use in the treatment of poor quality water by ozone injected from the bottom of a pressurized ozone contact tank. Under study as oxidation accelerating processes using ozone center about an ozone/hydrogen peroxide treatment, ozone/UV treatment, ozone/hydrogen peroxide/UV treatment, etc. As the result of testing, important respects in accelerated oxidation are learned, which are stated below. In the ozone-aided treatment, there are some substances, such as chromatic matters, that can be removed more rapidly when in direct contact with gaseous ozone. In this case, the concentration of remnant ozone poses an important problem. In relation to the amount of injected hydrogen peroxide, what is important is the ozone/hydrogen peroxide injection ratio relative to the substance that is to be removed. In the use of UV rays, since the decomposition rate of dissolved ozone is approximately ten times higher than that ...
1997-12-19
The operating experience for Wolsung Unit 3 commissioning
International Nuclear Information System (INIS)
This is a slide-based oral presentation given to the COG/IAEA: Fifth technical committee meeting on 'Exchange of operating experience of pressurized heavy water reactors' held in Mangalia, Romania on 7-10 September 1998. Since energization of Wolsung Unit 3 station service transformer on July 12, 1996 a line of initial test program was conducted as follows: 1. ILRT/SIT; 2. Pre-operational and Hot Functional testing with a Light Water and without Fuel in Systems; 3. Load D_2O in Moderator System; 4. Initial fuel loading; 5. Load D_2O in PHT System; 6. Hot Functional Testing with Heavy Water and Fuel in Systems; 7. Criticality and Low Power Physics Testing; 8. Power Ascension Test and, then finally, phase-D test; the plant acceptance test was accomplished after having a Mini-Overhaul to prepare for Commercial Operation. These documents contain not only both overall introduction of ...
1998-09-07
Energy Technology Data Exchange (ETDEWEB)
Volume 2 of the water resources data for the 1992 water year for Oklahoma consists of record of stage, discharge, and water quality of streams; stage, contents, and water quality of lakes or reservoirs; and water levels of ground-water well. The report contains discharge records for 136 gaging stations; stage and contents for 31 lakes or reservoirs; water quality for 50 gaging stations. Also included are 61 partial-record or miscellaneous streamflow stations and 28 ground-water sites.
1993-04-01
Energy Technology Data Exchange (ETDEWEB)
A meeting was held on October 15, 16, 17, 1990 to discuss the state of tritium safety and environmental effects. The meeting was organized with the help of the International Energy Agency planning committee consisting of K. Steinmetz, Y. Seki, G. Nardella, and G. Vivian. Representative of tritium production facilities and heavy water reactor power production were also involved. The meeting was organized to address seven topics in tritium safety that were thought to require further work. The topics were: (1) materials science, (2) environmental models, (3) environmental model validation, (4) tritiated organic compounds, (5) human dosimetry, (6) tritium sampling and measurement, and (7) long-term environmental databases.
1991-04-18
British Library Electronic Table of Contents (United Kingdom)
The aim of this study was to estimate the sensitivity of biomarkers of stress and exposure in the bivalve mollusk Anodonta cygnea to spontaneous anthropogenic activities typical for the Western Ukraine. Three sites were examined during spring, summer and autumn: an agricultural site (A); the cooling pond of nuclear power plant (N) and a forestry close to the municipal water inlet (F). Common temporal changes of a battery of biochemical markers in the gills and hemolymph and morphological characteristics were shown by discriminant functional analysis. Classification trees built on the basis of the screened biomarkers demonstrated persistent peculiarities at each site: genotoxicity (nuclear abnormalities) at site A and endocrine disruption (high levels of vitellogenin-like proteins (Vtg-LP) ...
2010-01-01
Utilization of geothermal energy in the USSR
International Nuclear Information System (INIS)
This paper reports that at present geothermal energy is utilized in the USSR mostly for district heating, and for industrial and agricultural purposes. The populations of 7 towns have district heating that is supplied by thermal waters. The population supplied totals about 125,000 people. The total area of greenhouses is 850,000 m"2. Electric energy generated at geothermal power stations still remains negligible with the installed capacity of the single Pauzhetka station (Kamchatka) being 11 MW. another station at Mutnovka is currently under construction and is expected to be producing 50 MW by 1992 and 200 MW by 1998. The proven geothermal resources in the USSR provide hope for a significant increase in the utilization of the earth's deep heat in the near future.
1990-08-20
International Nuclear Information System (INIS)
The PANDA test facility at PSI in Switzerland is used to study the long-term Simplified Boiling Water Reactor (SBWRT) Passive Containment Cooling System (PCCS) performance. The PANDA tests demonstrate performance on a larger scale than previous tests and examine the effects of any non-uniform spatial distributions of steam and noncondensables in the system. The PANDA facility is in 1:1 vertical scale, and 1:25 'system' scale (volume, power, etc.). Steady-state PCCS condenser performance tests and extensive facility characterization tests have already been conducted. A series of transient system behavior tests have been completed by end of 1995. Results from the first three transient tests (M3 series) are reviewed. The first PANDA tests exhibited reproducibility, and indicated that the SBWR containment is likely to be favorably responsive and highly robust to changes in the thermal transport patterns. (author) 6 figs., 11 refs.
The ageing of CANDU steam generator due to localized corrosion
International Nuclear Information System (INIS)
The Steam Generator (SG) tubing degradation caused by corrosion and other age-related mechanisms continues to be a significant safety and cost concern for many Nuclear Power Plants (NPP). The understanding of the steam generator ageing mechanisms is the key to effective management of steam generator ageing and consists of the knowledge of steam generator materials and these one properties, stressors and operating conditions, like degradation sites and wear mechanisms. The principal types of corrosion are presented which can occur in CANDU steam generator. There are also presented the operation conditions, the specifications referring to the water chemistry and the construction materials of Steam Generator, the factors that have a great influence on the corrosion behaviour during the whole exploitation period of this equipment. (R.P.)
2001-09-17
The Lithium future-resources, recycling, and the environment
British Library Electronic Table of Contents (United Kingdom)
Abstract:- The demand for Lithium-ion batteries as a major power source in portable electronic devices and vehicles is rapidly increasing. I use cumulative data of vehicle, mobile phone, laptop, and digital camera production to show that demand will overshoot the available global Lithium resources before 2025. Even if 100% of all Lithium-ion batteries were recycled today, recycling could not prevent this resource depletion in time. As the increasing Lithium scarcity will increase the price, it will be feasible to mine diluted resources with a strong environmental impact. I highlight these impacts in Lithium-rich Bolivia, the potential new -Saudi Arabia of Lithium.- Lithium extraction is likely to cause substantial water pollution, and-through impacts on native diversity-facilitate human he...
2011-01-01
International Nuclear Information System (INIS)
The Structural Aging (SAG) Program is carried out by the Oak Ridge National Laboratory (ORNL) under sponsorship of the United States Nuclear Regulatory Commission (USNRC). The Program has evolved from preliminary studies conducted to evaluate the long-term environmental challenges to light-water reactor safety-related concrete civil structures. An important conclusion of these studies was that a damage methodology, which can provide a quantitative measure of a concrete structure's durability with respect to potential future requirements, needs to be developed. Under the SAG Program, this issue is being addressed through: establishment of a structural materials information center, evaluation of structural component assessment and repair technologies, and development of a quantitative methodology for structural aging determinations. Progress to date of each of these activities is presented as well as future plans. 7 refs., 5 figs.
1989-08-14
Reflux boiling heat removal in a scaled TMI-2 system test facility
International Nuclear Information System (INIS)
An investigation of decay heat removal by the reflux boiling process was performed on a 1/18 linear-scaled test facility simulating the Three Mile Island (TMI-2) primary system. The objective was to clarify reflux boiling phenomena and core cooling effectiveness. Principal test variables included: core power, primary system water and gas inventories, and steam generator secondary-side coolant flow rate. Of 49 tests conducted, 43 achieved a steady-state heat rejection mode within 3 hours. Subsequent analyses identified two distinct reflux boiling modes. Based upon our current understanding, reflux boiling appears to be an effective process for removing decay heat in a broad range of the conditions investigated for a plant of the TMI configuration.
1980-06-01
Prospects of wind energy in Bangladesh
Energy Technology Data Exchange (ETDEWEB)
Wind speed has been measured in Patenga, Cox`s Bazar, Kuakata, Moheshkhali, and Noakhali by the computerized anemometers. The wind computers have been installed at 20 meters height. According to this study annual average wind speeds in the coastal regions of Bangladesh are greater than 6.5 m/s at the height of 20 meters. It has been observed that during day times (8 a.m. to 7 p.m.) wind speeds are about 30 to 40% higher than the average values. The value of the power exponent {alpha} has been determined in the above sites and it is 0.139. So, at 40 meters height the annual average wind speed is about 7.15 m/s. So, wind speeds in the coastal regions of Bangladesh are suitable for both water pumping and electricity generation. Details are given in this paper with graphical and analytical representations. (author)
1996-09-01
Pre-test report on international round robin analysis of BARC containment (BARCOM) test model
International Nuclear Information System (INIS)
BARC has organized an international round robin analysis program to carry out the ultimate load capacity assessment of BARC containment (BARCOM) test model. The test model located in BARC facilities Tarapur, is a 1:4 scale representation of 540 MWe pressurized heavy water reactor (PHWR) pre-stressed concrete inner containment structure of Tarapur Atomic Power Station (TAPS) unit 3 and 4. The features of the BARCOM test model and the constitutive data for the pre-test analysis along with the comparison of the results submitted by various participants are described in this pre-test report of the round robin analysis of BARCOM test model
2009-01-01
Modelling of two-phase natural circulation in a WWER-plant: PMK experimental results
International Nuclear Information System (INIS)
Experiments have been performed with the PMK integral-type facility, a model of WWER-440 type PWRs, to investigate two-phase natural circulation behaviour. The phenomena to be expected in this reactor type are different from those in PWRs with vertical steam generators mainly due to the loop seal in the hot leg and the horizontal layout of the steam generator heat transfer tubes. The experiments showed that the system is repressurized when the water level drops to the hot leg elevation due to the effect of the loop seal. Opening of the loop seal can be smooth, but may lead to oscillations depending on the power and the mass inventory. Natural circulation recovers after the hot leg loop seal is opened, but then decreases with further mass inventory decrease. (orig.).
Energy Technology Data Exchange (ETDEWEB)
In order to apply chemical-looping combustion to a practical power plant, carbon deposition on the solid particle is one of the key problems to be overcome. Six kinds of solid particles were examined to clarify the kinetic behavior of carbon deposition. The effects of the solid composition, feed gas composition, and reaction temperature on carbon deposition were investigated by thermogravimetrical reactor on the basis of NiO/YSZ particle. From the viewpoints of both reactivity and resistance against carbon deposition, the particle of NiO mixed with YSZ (i.e., yttria-stabilized zirconia) was found to be a good candidate for chemical-looping combustion. It has been observed that carbon deposition could be completely avoided with very low concentration of water vapor. By means of a proposed model, the condition that carbon deposition would be avoided was identified. 12 refs., 8 figs., 2 tabs.
1998-03-01
Energy Technology Data Exchange (ETDEWEB)
Apart from condensing the off-air condensers have a number of additional functions, which have been added more or less incidentally as development progressed. Advanced development of certain types of turbine condensers justifies the hope that these additional functions can be improved as power plants become cheaper and simpler.(orig.) [German] Kondensatoren haben neben ihrer Hauptaufgabe, der Kondensation des Turbinenabdampfes eine Reihe zusaetzlicher Funktionen, die sich z.T. im Laufe der Entwicklung eher beilaeufig ergeben haben. Der hohe Entwicklungsstand bei bestimmten Bauarten von Turbinenkondensatoren laesst die Erwartung zu, dass im Zuge der Vereinfachung und Verbilligung von Kraftwerksanlagen 'Nebenfunktionen' verbessert werden koennen. (orig.)
1998-07-01
Energy Technology Data Exchange (ETDEWEB)
Utilisation of geothermal energy may soon become an important factor in power supply in Germany. The contribution discusses the utilisation of hydrothermal low-pressure systems, the geological boundary conditions, the technical design of the thermal water cycle, and the current status of the hot dry rock technology. [German] Die Nutzung der Energie ausd Erdwaerme kann in naher Zukunft eine wichtige Rolle in der Energieversorgung Deutschlands spielen. Der vorliegende Artikel gibt einen Ueberblick ueber die Nutzung hydrothermaler Niederdrucksysteme, die geologischen Rahmenbedingungen, den technischen Aufbau des Thermalwasserkreislaufes sowie zum aktuellen Stand des Hot Dry Rock Verfahrens.
2001-07-01
Evaluation of validity of the RELAP5/MOD3 flow regime map for horizontal tubes
Energy Technology Data Exchange (ETDEWEB)
RELAP5/MOD3 code was developed for western type power water reactors with vertical steam generators. Thus, this code should be validated also for VVER design with horizontal steam generators. The validation work, which has been started in Lappeenranta University of Technology (LUT), has already shown some weaknesses of the code. For example the flow inside a steam generator horizontal tube in some accident cases is not correctly modelled by the code. It may be the result of erroneous prediction of the flow regime. The aim of the study is the attempt of verification of the flow regime map, which is used in the RELAP5/MOD3 computer code for two-phase flow in horizontal tubes. (18 refs.).
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
With the issuance of the Decommissioning Rule (July 27, 1988), nuclear power plant licensees are required to submit to the US Regulatory Commission (NRC) for review, decommissioning plans and cost estimates. This user`s manual and the accompanying Cost Estimating Computer Program (CECP) software provide a cost-calculating methodology to the NRC staff that will assist them in assessing the adequacy of the licensee submittals. The CECP, designed to be used on a personnel computer, provides estimates for the cost of decommissioning PWR plant stations to the point of license termination. Such cost estimates include component, piping, and equipment removal costs; packaging costs; decontamination costs; transportation costs; burial costs; and manpower costs. In addition to costs, the CECP also calculates burial volumes, person-hours, crew-hours, and exposure person-hours associated with decommissioning.
1993-10-01
Development of barcode system for internal dose monitoring
International Nuclear Information System (INIS)
In Tarapur Atomic Power Station unit-3 and 4, which is 540 MWe pressurized heavy water reactor, tritium is produced in primary heat transport system and moderator system. Tritium is a major contributor to the internal dose. Internal dose contributes about 30% of the collective dose. Internal dose monitoring and its control are important to control the collective dose. Estimation of internal dose is done by analysis of bioassay samples of radiation workers. In a month, about 7000 bioassay samples are analysed for the internal dose assessment during normal operation, and about 12000 during the biennial shut down of the reactor. To enhance the sample preparation and counting performance, minimize the entry errors and reduce the processing time, barcode based label generation system was developed for the internal dose monitoring. This paper discusses about the use of barcode system in the internal dose monitoring at TAPS 3 and 4. (author)
2008-11-19
Energy Technology Data Exchange (ETDEWEB)
Conditions of the separation and detection of organic and inorganic anions by gradient ion chromatography and suppressed conductivity detection were studied, and the procedure of gradient elution was optimized. A detection limit of 1 x 10{sup -3} {mu}g x L{sup -1} was obtained using the pre-concentrated column and most relative standard deviations obtained in the determination of seven organic and inorganic anions were below 5%. This method was proved to be simple, rapid and accurate for the separation and determination of low-molecular-weight organic acids and inorganic anions and could be applied in the analysis of the samples from water and steam systems of thermal power plants with satisfactory results. (orig.)
2007-03-15
Energy Technology Data Exchange (ETDEWEB)
Briefly described is knowledge of crevice corrosion, corrosion cracking and denting. In evaluating the corrosion resistance of steam generator materials it is necessary to distinguish corrosion problems caused by the primary coolant side and by the secondary circuit side. At present tubes are manufactured of 7 austenitic alloys of a different chemical composition, and available information shows that views on their corrosion resistance differ. Greatest attention has been devoted to corrosion cracking in the presence of NaOH. Findings related to I-600, I-800, I-690 and AISI 316 are given. Corrodibility by sulfur-containing products is now being studied, namely the intercrystalline corrosion cracking caused by the presence of H/sub 2/S/sub 4/O/sub 6/. Knowledge gained in this respect is summed up.
1984-07-01
International Nuclear Information System (INIS)
Briefly described is knowledge of crevice corrosion, corrosion cracking and denting. In evaluating the corrosion resistance of steam generator materials it is necessary to distinguish corrosion problems caused by the primary coolant eide and by the secondary circuit side. At present tubes are manufactured of 7 austenitic alloys of a different chemical composition, and available information shows that views on their corrosion resistance differ. Greatest attention has been devoted to corrosion cracking in the presence of HaOH. Findings related to I-600, I-800, I-690 and AISI 316 are given. Corrodibility by sulfur-containing products is now being studied, namely the intercrystalline corrosion cracking caused by the presence of H_2S_4O_6. Knowledge gained in this respect is summed up. (J.P.).
Containment integrated leakage rate test (ILRT) of Indian PHWR
International Nuclear Information System (INIS)
Integrated Leakage Rate Test (ILRT) of containment system plays a very important role in safety of a Nuclear Power Plant. Containment system constitutes the last physical barrier to release of radioactivity from the core and is called upon to mitigate the consequences of not only accidents within the design basis, but also some of the highly unlikely severe accidents. Hence, leak tightness of containment becomes uttermost priority for the safety of plant personnel and public. The containment and associated ESFs are tested before the first criticality and there after periodically during service. The pre-operational integrated leakage rate is carried out at LOCA based design pressure, at periodic test pressure and at some intermediate pressure points to assess the leakage characteristics. This paper summarizes the various requirements and activities relevant to the ILRT of the Indian Pressurized Heavy Water Reactor (PHWR) containment system. ...
2005-12-01
Energy Technology Data Exchange (ETDEWEB)
Despite the current global economic crisis, the Cleantech industry has excellent growth prospects. Especially technologies for water treatment, energy efficiency in buildings and combined heat and power will face high demand and high growth rates in the coming years, just like the suppliers for the wind and solar industry. Today German companies are market leaders in these segments. However, there is a threat that they will lose this competitive position as international competition increases. Besides attractive incentive schemes and regulatory framework, access to venture capital and the fast expansion to international markets is an important factor to secure the leading market position of German Cleantech companies. (orig.)
2009-07-01
British Library Electronic Table of Contents (United Kingdom)
Abstract Characteristics of batch rotor-stator mixer performance are elucidated by shaft torque and angle resolved 2D PIV measurements obtained in a full-scale, custom build, bottom-mounted, rotor-stator mixer unit operating in the turbulent regime with water as working fluid. Measurements have been acquired at various rotor speeds corresponding to impeller based Reynolds numbers between 2.0--105 and 8.5--105. The use of a transparent Plexiglas stator facilitated PIV measurements inside and outside the stator as well as into the stator slots themselves. The governing mechanisms controlling the complex flow structures, flow rates, power dissipation, velocity fields, strain rate fields and turbulence intensity fields are explained, highlighting the influence on rotor-stator mixer performance...
2011-01-01
Application of leak-before-break approach to PWR piping designed by Babcock and Wilcox: Final report
Energy Technology Data Exchange (ETDEWEB)
Recently, the leak-before-break (LBB) concept has been used successfully to eliminate some pipe whip restraints, snubbers and jet impingement shields from the primary reactor cooling system piping of pressurized water reactors. This has resulted in substantial savings in maintenance costs, reductions in radiation exposure of plant service personnel, and has enhanced the overall safety of nuclear power plants. This study provides guidelines to utilities in expanding the application of the LBB concept to additional pipe systems and it couples the concept with hardware optimization. Seven high energy piping systems were investigated for technical feasibility in using the LBB concept. The results indicate that some of these seven lines are good candidates for the leak-before-break application.
1987-01-01
Accelerated aging corrosion tests for buried metal structures
Energy Technology Data Exchange (ETDEWEB)
It is necessary to identify those measurable soil parameters which dictate the severity of the corrosion problem for coated irons and steels. When this is done, meaningful accelerated aging tests can be designed to validate the reduced corrosion rate for the planned coating. The following discussion introduces the important concepts and measurement parameters in the (a) design of accelerated aging tests, and (b) evaluation of the planned installation site for corrosion potential. Certain combinations of soil oxidation reduction potential (ORP) or electric potential (Eh), acidity (pH), fertilizer, water table, and soil hydraulic conductivity can result in severe corrosion of buried steel/iron vessels. If there are power lines nearby, additional loss of vessel material to the soil will occur. These factors are discussed.
1996-10-01
Energy Technology Data Exchange (ETDEWEB)
The LS electromagnetic band (1-4 GHz) is widely used both in domestic and industrial domains. Several studies suggested that the biological systems would exhibit a specific sensitivity to the 2.45 GHz microwaves (water resonance frequency). Potential human health hazards and especially a disruption of the cholinergic system have been reported, due to exposure to microwaves even at low power density. This work presents a multi-parametric study of freely moving rat where neuro-physiology was investigated during 70 hours using neurochemical (micro-dialysis technique), electrophysiological, behavioral (vigilance stages quantification) and thermo-physiological approaches. The rats were exposed 24 hours to a 2.45 GHz pulsed electromagnetic field at low power density. In this exposure conditions, no significant effect have been reported. (authors)
2007-06-15
Suitability of filter ash surfaces as locations for plants
Energy Technology Data Exchange (ETDEWEB)
The possibility of a positive agricultural use of flue gas filter ash from brown coal power plants is investigated. The suggested measure is mixing ash dump surfaces with extremely acidic spoil bank soils, which balances the high pH value of the alkaline ash and contributes to improved nutrient and soil sorptive conditions. Optimum quantity of spoil bank sands in the mixture with ash is between 10% and 40%. The optimum quantity must be determined for each type of ash considering improvement of soil chemical conditions and water retention capacity. Filter ash properties vary widely; the required amount of spoil bank sand added to investigated ash surfaces near 3 brown coal power plants was between 25% and 30% of the mixture. The same favourable soil and ash mixture can be produced by adding 60% to 75% filter ash to acidic raw spoil bank soil surfaces forming a top soil layer in a thickness of minimum 60 cm. Tests of plant ...
1980-01-01
International Nuclear Information System (INIS)
Tarapur Atomic Power Station Unit-3 and 4 (TAPS -3 and 4) are the 540 MWe reactors. Unit-4 attained first criticality on 06th March 2005 and operated for about 230 effective full power days (EFPD). Unit-3 attained first criticality on 21st May 2006 and operated for about 20 EFPD. With the reactor operation radiation field increases on the Primary Heat Transport system equipments, Moderator system equipments and auxiliary system equipments due to deposition of fission products and activation products in different reactor systems. These dose rates significantly contributes to the external exposure and stations collective dose during reactor operation, refueling operation and maintenance activities. A study was undertaken at TAPS 3 and 4 to identify the system equipments showing the significant dose rates and identify the radionuclides present in the primary heat transport system, Moderator systems, cover gas system and other auxiliary system for ...
2006-11-13
Simulation of SBWR startup transient and stability
The Simplified Boiling Water Reactor (SBWR) designed by General Electric is a natural circulation reactor with enhanced safety features for potential accidents. It has a strong coupling between power and flow in the reactor core, hence the neutronic coupling with thermal-hydraulics is specially important. The potential geysering instability during the early part of a SBWR startup at low flow, low power and low pressure is of particular concern. The RAMONA-4B computer code developed at Brookhaven National Laboratory (BNL) for the SBWR has been used to simulate a SBWR startup transient and evaluate its stability, using a simplified four-channel representation of the reactor core for the thermal-hydraulics. This transient was run for 20,000 sec (5.56 hrs) in order to cover the essential aspect of the SBWR startup. The simulation showed that the SBWR startup was a very challenging event to analyze as it required accurate ...
1998-06-01
Risk oriented analysis of the SNR-300
International Nuclear Information System (INIS)
The Fact Finding Committee on 'Future Nuclear Power Policy' established by the 8th German Federal Parliament in its report of June 1980 among other items published the recommendation to commission a 'risk oriented analysis' of the SNR-300 in order to enable a pragmatic comparison to be made of the safety of the German prototype fast breeder reactor and a modern light water reactor (a Biblis B PWR). The Federal Minister for Research and Technology in August 1981 officially commissioned the Gesellschaft fuer Reaktorsicherheit (GRS) to conduct the study. Following a recommendation by the Fact Finding Committee, additional studies were performed also by a group of opponents of the breeder reactor. On the instigation of the group of opponents the delivery date of the study was altered several times and finally set at April 30, 1982. GRS submitted its report by this deadline. However, a joint report by the two groups could not be compiled, as had ...
Pumps and compressors - buyers` guide 1996/`97; Pumpen und Kompressoren - Einkaufsfuehrer 1996/97
Energy Technology Data Exchange (ETDEWEB)
The 1996/`97 buyers` guide comprises ten chapters: 1. List of suppliers; 2. Waste management, effluents, sewage systems; 3. Water supply, hydroengineering; 4. Chemistry, petrochemistry; 5. Chemical engineering; 6. Food industry, biotechnology; 7. Paper and cellulose industry; 8. Natural gas industry, natural gas supply; 9. Power plant engineering, power systems, district heating; 10. Air conditioning and refrigeration engineering. (orig.) [Deutsch] Der vorliegende Einkaufsfuehrer 1996/97 ist in zehn Kapiteln gegliedert. Diese sind: 1. Firmenverzeichnis 2-11 2. Entsorgungs-/Abwassertechnik, Klaeranlagen 12-15 3. Wasserversorgung, Wassertechnik 16-18 4. Chemie, Petrochemie 19-22 5. Verfahrenstechnik 23-26 6. Lebensmittelindustrie, Biotechnik 27-29 7. Papier-, Zeluloseindustrie 30-31 8. Erdgasindustrie, -versorgung 32 9. Kraftwerkstechnik, Energieanlagen, Fernwaerme 33-34 10. Kaelte-/Klimatechnik 35-36. (orig.)
1996-12-01
Nomographs for H[sub 2]O-LiBr absorption-panel cooling systems
Energy Technology Data Exchange (ETDEWEB)
Panel cooling of buildings offers energy savings over conventional space-cooling systems. We present a procedure for calculating the performance of H[sub 2]O-LiBr absorption-panel cooling systems, in which the evaporator is the panel itself. Nomographs have been developed for this approach. Under the conditions examined, the H[sub 2]O-LiBr absorption unit operates with a theoretical performance coefficient of about 90% and with a practically constant specific cooling capacity of 2394 kJ/kg H[sub 2]O. For common values of the parameters involved, the panel cooling power varies from 25 to 175 W/m[sup 2] and the cooling water mass-flow through the panel is 40-260 g/m[sup 2]h. The thermal power needed to drive the system varies from 27 to 200 W/m[sup 2] and the associated temperatures from 70 to 100[sup o]C; thus, the system may be operated on solar energy. (Author).
1992-11-01
International water power and dam construction handbook
Energy Technology Data Exchange (ETDEWEB)
The first section of this Handbook describes hydro-electric projects currently under construction or recently commissioned in a number of countries. The major part of the Handbook is devoted to lists of data relating to hydro-electric plants and hydromachinery. These include: data for 1990 submitted by national power authorities on hydro-electric and pumped-storage plants in operation, under construction or planned; more detailed data for pumped-storage plants; country by country data on the dimensions, and reservoir and electrical capacity of major dams and hydro plant; a listing of roller compacted concrete dams; a listing of the world's largest turbines giving data on the largest unit at each scheme in rank order ranging from a unit capacity of 838 MV down to 147 MV; a similar list of the largest hydrogenerators ranging from a unit capacity of 825 MVA down to 150 MVA; details of turbine and generator contracts. The handbook concludes with an address ...
1992-01-01
International Nuclear Information System (INIS)
Presently no one knows whether electromagnetic fields (EMFs) play a role in human cancer or other ailments, though epidemiological studies over the years have suggested that possibility. A study by the Electric Power Research Institute attempted to quantify everything it could about the magnetic environment of a home, identifying not only major sources of magnetic fields, but also their frequencies, strengths, and how they fall off with distance. Sources of a homes magnetic environment include appliances, overhead powerlines, and grounding connections to metallic water pipes. Fields will vary over time, depending on how much current is passing through the electrically conductive sources. Additional contributors to a home's magnetic background may include unusual wiring in the walls, underground power lines, and near-by high voltage transmission lines. This paper summarizes the study results, indicating weak, persistant EMFs ...
1993-08-01
Design modifications in 540 MWe and its impact on the dose rates
International Nuclear Information System (INIS)
Exposure control at the operating Nuclear Power Station is a major concern. TAPS Unit-4 is the first Pressurized Heavy Water Reactor of 540 MWe electrical capacity. This unit was made critical on March 6, 2005. In-depth review of radiation safety was done to identify the impact of design modification on dose rates at various locations and on the equipment's. Problems encountered in controlling the dose rates in 220 MWe electrical are eliminated by appropriate design modifications. Due to higher capacity of the unit there are design changes in major systems such as reactor core, primer heat transport system, moderator system, reactor regulation and protection systems. Reactor operations and maintenance activities during shut down contributes to exposure of the employees. Based on the experience gained in the operation of 220 MWe, design modifications incorporated in TAPS unit-4 and dose rate measurements carried out at 90 % full ...
2005-11-23
International Nuclear Information System (INIS)
2-hydroxyethyl methacrylate (HEMA) has been deposited onto the surface of silicon substrate (thickness = 500 ?m) using plasma polymerization technique. Polymerization process was carried out in an in-house developed inductively coupled plasma polymerization setup. The depositions were carried out using RF power supply (13.56 MHz) at power of 75 W for 10 and 40 min. The RF supply was coupled to the inductance through a matching network. The effect of plasma polymerization (surface grafting) on the degree of surface modification has been investigated. The chemical changes on the polymer backbone are followed from the results of Fourier transform infrared (FTIR) spectroscopy and X-ray photoelectron spectroscopy (XPS), which show the peaks corresponding to the functional groups of the HEMA polymerized onto the silicon surface. The morphology of the modified surfaces has also been investigated using scanning electron microscopy (SEM) and atomic ...
2005-05-30
International Nuclear Information System (INIS)
The design boron concentration of the Boron Injection Tank (BIT) in Daya Bay Nuclear Power Station is 21000 #mu#g/g. The BIT should operate under high temperature to avoid boron crystallization, causing higher evaporation, frequent water makeup, higher deposition and pipe blockage to decrease the operability of the safety injection system. The author proposes to decrease the boron concentration in BIT from 21000 #mu#g/g to 7000 #mu#g/g to solve the existing problem. The safety analyses (core DNBR and containment response) are conducted and other impacts are evaluated for the BIT reduction. The analysis results show that the core DNBR meets the safety criterion and the containment pressure is within the design value for the steam line rupture accident after the BIT reduction. The feasibility study report of Daya bay BIT reduction has been approved by NNSA. The site implementation of BIT reduction has been finished successfully
1999-12-01
Combined cycle power plant with integrated low temperature heat (LOTHECO)
International Nuclear Information System (INIS)
The major driver to enhance the efficiency of the simple gas turbine cycle has been the increase in process conditions through advancements in materials and cooling methods. Thermodynamic cycle developments or cycle integration are among the possible ways to further enhance performance. The current paper presents the possibilities and advantages from the LOTHECO natural gas-fired combined cycle concept. In the LOTHECO cycle, low-temperature waste heat or solar heat is used for the evaporation of injected water droplets in the compressed air entering the gas turbine's combustion chamber. Following a description of this innovative cycle, its advantages are demonstrated by comparison between different gas turbine power generation systems for small and large-scale applications, including thermodynamic and economic analysis. A commercial gas turbine (ALSTOM GT10C) has been selected and computed with the heat mass balance program ENBIPRO. The results ...
2004-08-01
Chalk Point cooling tower project native vegetation study. Final report 1979
The Potomac Electric Power Company generating station at Chalk Point, MD, utilizes brackish water in its natural draft cooling tower and, consequently, releases saline aerosol into the atmosphere. A research and monitoring project was established in 1974 to evaluate the effects of this drift on native perennial vegetation. Leaf samples have been collected form dogwood, Cornys florida, Virginia pine, Pinus virginiana, black locust, Robinia pseudoacacia, and sassafras, Sassafras albidum, located at 12 different sites in the vicinity of the power plant. Sampling was begun prior to the operation of the cooling tower, 1974, and continued through 1978. Complete results from monthly monitoring of foliar chloride in the four native tree species is documented for May through September 1978. Results from salt spray experiments indicate chloride and sodium concentrations in the wood of dogwood trees increases with increased spraying ...
1979-06-01
Application of a finite element method to leak before break (LBB) of a heat exchanger
International Nuclear Information System (INIS)
The leak before break (LBB) concept is difficult to apply to a structure with a thin tube that is immersed in a water environment. A heat exchanger in a nuclear power plant is such a structure. The present paper addresses an application of the LBB concept to a heat exchanger in a nuclear power plant. The minimum leaked coolant amount containing the radioactive material which can activate the radiation detector device installed near the heat exchanger is assumed. The postulated initial flaw size that cannot grow to the critical flaw size within the time period to activate the radiation detector is justified. In this case, the radiation detector can activate the warning signal caused by coolant leakage from initially postulated flaws of the heat exchanger. The nuclear plant can safely shutdown when this occurs. Since the postulated initial flaw size can not grow to the critical flaw size, the structural integrity of the heat ...
2003-08-17
International Nuclear Information System (INIS)
Research and development and other activities of the various constituent units of Department of Atomic Energy (DAE) and also of the institution aided by DAE for the year 2005-2006 are reported. The various constituents units of DAE consist of nuclear research centres, nuclear power stations, fuel reprocessing and heavy water plants, nuclear fuel fabrication facilities, electronic and instrumentation production organisations, atomic mineral processing units and other nuclear installations. The activities of DAE cover the whole gamut of nuclear fuel cycle, research and development in nuclear science and reactor technology, applications of radiation and radioisotopes, radiation protection, research and development in front line areas such as robotics, lasers, mathematics and computational sciences. International research collaborations like CERN-DAE collaboration were completed by BARC. These activities are described broadly under: executive ...
AP1000 plant construction in China: Ansaldo Nucleare contribution
International Nuclear Information System (INIS)
On 24th of July 2007 Westinghouse Electric Co. signed landmark contracts with China's State Nuclear Power Technology Corporation (SNPTC), to provide four AP1000 nuclear power plants in China. The AP1000 is a two-loop 1117 MWe Pressurized Water Reactor (PWR). It is based on proven technology, but with an emphasis on safety features that rely on natural driving forces, such as pressurized gas, gravity flow, natural circulation flow and convection. Ansaldo Nucleare has provided a significant support to the passive plant technology development and, starting from 2000, is cooperating with Westinghouse to development of the AP1000 Plant. In the frame of the AP1000 Chinese agreement, Ansaldo Nucleare, in Joint Venture with Mangiarotti Nuclear, has signed a contract with Westinghouse for the design and the supply of innovative components to be installed in the first AP1000 unit to be constructed at the Sanmen site. The contract ...
2009-10-12
Natural convection cooling of a vertical channel
International Nuclear Information System (INIS)
An experimental program has been conducted to determine the feasibility of natural convection cooling of a reactor following a beyond-design-based accident. The particular application under consideration was the heavy-water new production reactor. The questions to be resolved include the verification that a natural convection cooling pattern would be established and the determination of the power limit for which convective cooling will occur for a significant period of time. In the experiment, the reactor configuration was simulated using small-diameter vertical heated tubes in parallel with a large-diameter bypass line. Following a loss-of-flow event, the flow in the bypass line will reverse direction and pass through the heated channel by means of natural convection. If, however, the channel power is too high, void formation will block the channel and prevent the reverse flow pattern from occurring. The test procedure ...
1993-11-14
Feasibility of maintaining natural convection mode core cooling in research reactor power upgrades
International Nuclear Information System (INIS)
Two operational concerns for natural convection coooled research reactors using plate type fuels are: 1) pool top "1"6N activity (PTNA), and 2) nucleate boiling in core channels. The feasibility assessment of a power upgrade while maintaining natural convection mode core cooling requires addressing these operational concerns. Previous studies have shown that: a) The conventional technique for reducing PTNA by plume dispersion may not be effective in a large power upgrade of research reactors with small pools. b) Currently used correlations to predict onset of nucleate boiling (ONB) in thin, rectangular core channels are not valid for low-velocity, upward flows such as encountered in natural convection cooling. The PTNA depends on the velocity distribution in the reactor pool. COMMIX-1A code is used to determine the three-dimensional velocity fields in The Ohio State University Research Reactor (OSURR) pool as a function of varying design ...
1988-05-01
Demonstrating leadership inside and out : green building project trains employees, educates clients
Energy Technology Data Exchange (ETDEWEB)
This article described a full-scale green renovation project undertaken by a construction management firm in Newton, Massachusetts. Chapman Construction and Design began renovating its own office building in late 2007 and completed it in September 2008. The firm set out to achieve LEED Platinum certification from the United States Green Building Council. The project involved energy saving modifications to its mechanical systems; replacing plumbing fixtures with high efficiency alternatives to reduce water consumption by at least 40 per cent; installing skylights and additional windows to allow more natural light into the interior space; salvaging doors, lighting, metal studs and masonry whenever possible; and using sustainable products such as recyclable carpets, tiles and low-VOC paint. The main feature of the renovation was a new 47 kW (DC) photovoltaic (PV) solar power array installed on the rooftop. The PV array includes 208 panels and a ...
2009-01-15
English - Safe Water in an Emergency Click to Stop Video Click to Start Video To Listen to ...
Energy Technology Data Exchange (ETDEWEB)
As part of the demonstration testing of the Purge Water Management System (PWMS) technology at the Savannah River Site (SRS), four wells were equipped with PWMS units in 1997 and a series of sampling events were conducted at each during 1997-1998. Three of the wells were located in A/M Area while the fourth was located at the Old Radioactive Waste Burial Ground in the General Separations Area.The PWMS is a ''closed-loop'', non-contact, system used to collect and return purge water to the originating aquifer after a sampling event without having significantly altered the water quality. One of the primary concerns as to its applicability at SRS, and elsewhere, is whether the PWMS might resample groundwater that is returned to the aquifer during the previous sampling event. The purpose of the present investigation was to compare groundwater chemical analysis data collected at the four test ...
1999-04-27
Application of a power system stabilizer in the nuclear power plant Borssele
Energy Technology Data Exchange (ETDEWEB)
After that power fluctuations had occurred at Borssele nuclear power station it was decided to install a power system stabilizer. This stabilizer shall reduce the unwanted power fluctuations. The preliminary research and the results of measurements carried out during commissioning are described. (J.C.R.)
1985-03-01
Annual Report 1999. Electric power in Sweden
Energy Technology Data Exchange (ETDEWEB)
Barsebaeck 1 was closed on 30 November 1999. Barsebaeck's output of approximately 4 TWh per year will primarily be replaced by imports from coal-fired plants in Denmark and Germany. During the year, the closure of Swedish fossil-fired condensing power stations continued. With that, over 3,000 MW of peak-load power has been shut down during recent years. Consequently, situations entailing shortages of power can arise. On the deregulated electricity market, it is only the system operators that have a satisfactory overview of the overall electricity balance. The Swedish Power Association has thus lobbied the government as regards the need to elucidate Svenska Kraftnaet's responsibility. In a governmental decision from December, Svenska Kraftnaet was given the task of, among other things, monitoring the available capacity during peak loads and developing market instruments that can ...
2000-07-15
Energy Technology Data Exchange (ETDEWEB)
Cylindrical shells with regular perforation are widely used in power generating equipment and in particular in collectors 1 of the circuit of steam generators of power generating installations with water-water reactors (WWPR) The state of stress of collectors is determined by a broad spectrum of technological and operational loads, it is therefore difficult to analyze it theoretically. The aim of the present work is the experimental investigation of stresses in the cylindrical shells of collectors subjected to internal pressure, the generalization and systematization of empirical data in the form of engineering formulas and nomographs. The investigations were carried out with photoelastic three-dimensional models with the use of {open_quotes}freezing{close_quotes}. The basic characteristics of the state of stress of perforated shells (in particular those used in calculations of the strength and life of collectors) are the ...
1994-06-01
Development and application of high performance resins for crud removal
Energy Technology Data Exchange (ETDEWEB)
The development of crud removal technology has started with the finding of the resin aging effect that an old ion exchange resin, aged by long year of use in the condensate demineralizer, had an enhanced crud removal capability. It was confirmed that some physical properties such as specific surface area and water retention capacity were increased due to degradation caused by long year of contact with active oxygens in the condensate water. So, it was speculated that those degradation in the resin matrix enhanced the adsorption of crud particulate onto the resin surface, hence the crud removal capability. Based on this, crud removal resin with greater surface area was first developed. This resin has shown an excellent crud removal efficiency in an actual power plant, and the crud iron concentration in the condensate effluent was drastically reduced by this application. However, the cross-linkage of the cation resin had to ...
1998-12-31
Development and application of high performance resins for crud removal
International Nuclear Information System (INIS)
The development of crud removal technology has started with the finding of the resin aging effect that an old ion exchange resin, aged by long year of use in the condensate demineralizer, had an enhanced crud removal capability. It was confirmed that some physical properties such as specific surface area and water retention capacity were increased due to degradation caused by long year of contact with active oxygens in the condensate water. So, it was speculated that those degradation in the resin matrix enhanced the adsorption of crud particulate onto the resin surface, hence the crud removal capability. Based on this, crud removal resin with greater surface area was first developed. This resin has shown an excellent crud removal efficiency in an actual power plant, and the crud iron concentration in the condensate effluent was drastically reduced by this application. However, the cross-linkage of the cation resin had to ...
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.