Methods and apparatus are described for efficient photodetachment and purification of negative ion beams. A method of purifying an ion beam includes: inputting the ion beam into a gas-filled multipole ionguide, the ion beam including a plurality of ions; increasing a laser-ion interaction time by collisional cooling the plurality of ions using the gas-filled multipole ionguide, the plurality of ions including at least one contaminant; and suppressing the at least one contaminant by selectively removing the at least one contaminant from the ion beam by electron photodetaching at least a portion of the at least one contaminant using a laser beam.
Results of treatment of 30 children with Ewing's sarcoma irradiated in the First Radiotherapy Department, Cancer Center, Warsaw, in the period 1983-1992, are described. In 40% of patients NED survival from 1 till 10 years and in 70% the local control was obtained, and no serious radiations equelae were observed. (author).
The most important results of theoretical and experimental studies of plasmas, which have been achieved at the IPJ in Swierk and IPPLM in Warsaw recently, are presented. Studies of physical phenomena in PF discharges, development of diagnostic techniques and research on new plasma technologies, as performed at IPJ, have been summarized. Studies of dense magnetized plasmas, investigation of physics and applications of laser-produced plasmas; and research on the development of advanced diagnostic techniques for the EUROATOM fusion program, as performed at IPPLM, are also described.
We report, for the first time to our knowledge, on the active optical planar waveguides in Nd : YAG laser crystals fabricated by O3+ ion implantation at low doses of ?1014 ions cm-2. The reconstructed refractive index profiles based on the measured dark-mode spectroscopy show that an enhanced refractive index well is created in the near-surface region, forming a non-leaky waveguide structure. With thermal annealing treatment at 260 0C for 90 min, the propagation losses of the waveguides could be reduced to ?3 dB cm-1 at a wavelength of 632.8 nm. The micro-luminescence investigation reveals that the emission bands of Nd3+ ions are not significantly affected by the waveguide formation processing, which shows promising potentials for efficient waveguide laser operations at near-infrared wavelength bands.
The purpose of the Joint Task Force Headquarters Master Training Guide (JTF HQ MTG) is to provide a descriptive, performance-oriented training guide to assist leaders in training their units. It also serves as a guide for the JTF Headquarters in actual op...
The performance of larger than bench scale ion exchange systems is evaluated by using solutions containing trace amounts of "1"3"7Cs, "8"5Kr, and "1"3"1I, and large amounts of either NaCl or Na_2HPO_4, H_3BO_3, and LiOH. The significant finding in this study is that the empirical rules of ionic selectivity of strong acid cation and strong base anion resins were followed by all ionic species, even though concentrations of some macrocomponents were nearly 10"6 times those of trace components. Other results of possible importance are the correlation between the instantaneous decontamination factor (DF) and the efficiency of column exchange capacity utilization, and the concept of time average decontamination factor (anti DF). The plot of anti DF vs. feed throughput will serve as a guide in determining when the feed should be discontinued in order to achieve a desired anti DF. Both of these correlations are derived from the breakthrough curves.
In this paper the measurements of radon-222 concentration in the air of Kowary Radon Inhalatorium in the vicinity of Jelenia Gora, Lower Silesia, Poland, performed by Radiation Protection and Radiobiology Department of National Institute of Hygiene in Warsaw, have been presented. For the measurements the integration method with the application of charcoal canisters have been used. The radon concentration was found within the very broad ranges from about 4 to 420 kBq m"-"3 depending of the season of the year. Basing on the radon concentration measurements during the inhalation therapy session and taking into account the equilibrium factor of 0.8 the doses to the bronchi of the patients in range from 1.2 to about 204 mSv (0.12-20.4 rem) have been assessed. The majority of patients (ca. 76%) received the doses between 115 and 204 mSv. (author)
Last year, 1991, was a difficult one for Finland's oil and chemicals company, Neste Corporation. The sharp fall in the international price of chemicals products had a significant impact on the corporation's overall result. Neste was, however, able to improve its competitive position, move ahead with numerous investments, and develop new businesses. This was particularly evident in two areas that have received significant emphasis within Neste in recent years: oil exploration and the Baltic region where a network of modern service stations in Neste livery and stretching from Vyborg on the Finnish-Russian border, through St. Petersburg, Tallinn, and the Baltic countries to Warsaw, is currently taking shape. The majority of the western-style stations in this network will be located along the route of the M12 highway, which has been dubbed the Via Baltica.
...A-Z list of ESDS guides Economic and Social Data Service - User support - ESDS guides | Home | A-Z index ...uk Telephone: +44 (0)1206 872143 Fax: 01206 872003 Print-friendly page A-Z list of ESDS guides Printing tips Printing tips The majority of these guides are web pages with a ... To print these guides at their best: select 'print friendly' at the top-right of the content of the page go to File/...via Beyond 20/20 WDS Advice for new users Analysing Change Over Time: A guide to ESDS resources CommonGIS functionality guide Countries and Citizens: Linking ...
The diagnostic designs for the Laser Megajoule (LMJ) will require components to operate in environments far more severe than those encountered in present facilities. This harsh environment will be induced by fluxes of neutrons, gamma rays, energetic ions, electromagnetic radiations, and, in some cases, debris and shrapnel, at levels several orders of magnitude higher than those experienced today on existing facilities. The lessons learned about the vulnerabilities of present diagnostic parts fielded mainly on OMEGA for many years, have been very useful guide for the design of future LMJ diagnostics. The present and future LMJ diagnostic designs including this vulnerability approach and their main mitigation techniques will be presented together with the main characteristics of the LMJ facility that provide for diagnostic protection.
When the history of neutrons is considered, three large discoveries are recalled, that is, the discovery of neutrons by Chadwick in 1932, the discovery of the nuclear fission of uranium by Hahn and Strassmann in 1938, and the continuation of chain reaction in nuclear fission by Fermi and others in 1942. In neutron capture reaction, the reaction cross section can become very large. The fields of research, to which neutrons have contributed most as the experimental probe, are neutron activation analysis and neutron diffraction. The development of the prompt gamma ray analyzer at the JRR-3M in Japan Atomic Energy Research Institute is reported. This method eliminates the various defects in ordinary neutron activation analysis. By installing the cold neutron source with hydrogen cooling in the JRR-3M, the new field of research was opened. As the combination of a lead-moderated spectrometer and an electron beam type accelerator, the Kyoto University lead slowing-down spectrometer, and as ...
The Guide is intended to provide guidelines for the initial preparation of FFTF Operating Procedures. The Procedures Preparation Guide was developed from the plan presented and approved in the FFTF Reactor Plant Procedures Plan, PC-1, Revision 3.
...Seeing-eye or guide dogs will remain in guiding...possible agitation of military police working dogs, seeing-eye or guide...allowed in or around working dog kennels and facilities...used for registering military personnel on...
This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users Guide. The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users Guide.
This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users' Guide. The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users' Guide.
...Keeping chickens: a beginner's guide : Directgov - Environment and greener living chickens, feeding chickens, egg marking, registering a ...flock, battery hens Chickens; Department for Environment, Food and Rural Affairs; Registrations; Animals; Livestock; Local government; Local ...authorities A guide for people keeping chickens on the laws for registering and feeding them, and how to spot key diseases. A ...guide for people keeping chickens on the laws for registering and feeding them, and how to spot key diseases. Keeping chickens: ...
The authors report the personal techniques and the results of CT-guided percutaneous drainage of postoperative abdominal fluid collections. CT-guided percutaneous drainage offers many advantages over surgery: it is less invasive, can be repeated and requires no anesthesia, there are not surgery-related risks and lower morbidity and mortality rates. Moreover, subsequent hospitalization is shorter and costs are consequently reduced. The authors conclude that CT-guided percutaneous drainage is the method of choice in the treatment of postoperative abdominal fluid collections.
Concentrations of tritium in environmental waters (precipitation, rivers, lakes, tap water) have been determined using electrolytic enrichment and liquid scintillation counting. In waters of big rivers (the Vistula and the Odra rivers), lakes and tap water the annual average concentrations were similar to each other being from 1.4 to 1.9 Bq x dm"-"3. These concentrations were similar to those in the precipitation in which they ranged from 1.7 to 2.2 Bq x dm"-"3. The lowest tritium concentrations were found in waters of the Seashore Region rivers (average for 1994-1999 was 1.1 Bq x dm"-"3). The tritium concentrations in surface waters and in precipitation are still higher than that of natural level. The data obtained show that tritium concentration in the water of rivers might depend on the size of drainage area. The observed seasonal variations of tritium concentration in the precipitation collected in Warsaw and at the Mount Sniezka indicate the stratospheric ...
The kinetic and guiding center fluid theories of high-..beta.. plasma containment in mirror machines have been developed in a number of self-consistent models. The geometrical effects of magnetic field and ambipolar potential variation have been incorporated in a bounce-averaged Fokker-Planck code which shows that the square-well model somewhat overestimates the n tau and ..beta.. achievable in a mirror field. Simple analytic approximations to the resulting pressure profiles have been incorporated in three-dimensional fluid-equilibrium codes which show the effect of coil geometry on the maximum ..beta... Strongly curved vacuum fields allow higher ..beta.., but short plasmas in weakly curved fields tend to reverse the curvature locally before the mirror-mode limit is reached. Adiabaticity of particle orbits is described in terms of general formulas, applicable in high-..beta.. plasma equilibria, and is shown to break down close to the mirror-mode limit. Two ...
This guide has been written to introduce growers of Short Rotation Coppice (SRC) to the principles and need for cold storage of planting material. The main types of cold store are described. It also provides assistance in the selection of suitable stores and how these are located nationally. (author)
...In your area Get connected Farmers & growers news Training & events Poultry (laying) Poultry production can be a profitable enterprise for organic farmers and eggs are ... To find out more about organic poultry production download our free comprehensive introductory guide: Organic poultry production - an introductory guide [PDF, ...
The guiding mechanism is attached by a hinge (swivel) to the supporting frame, and the frame is equipped by hinges (swivels) with hydraulic or pneumatic cylinders mounted on its ends and is attached by hinges (swivels) to the coke ejector and guide respectively. This increases the productivity and efficiency of operating the system.
This work reports the design of and experimentation with a topographically patterned cell culture substrate of variable local density and anisotropy as a facile and efficient platform to guide...Full Text Available
Sep 2, 2008 ... Abstract: This tutorial is intended to serve as a guide towards proper hazardous waste management. Knowing the regulations, different ...
The ROI Proposal Preparation Guide is a tool to assist Hanford waste generators in preparing ROI proposal forms for submittal to Department of Energy, Richland Operations Office (DOE/RL) for funding. The guide describes the requirements for submitting an ROI proposal and provides examples of completed ROI forms. The intent is to assist waste generators in identifying projects that meet the criteria, provide information necessary to complete the ROI forms, and submit a proposal that is eligible to receive funding.
A new procedure of fuel layering for the Fast Ignition Realization Experiment (FIREX) target is proposed. A conical laser guide heating technique was experimentally demonstrated in principle as the followings. It employed the target consisting of a polystyrene (PS) shell, a fill tube and a conical laser guide. At first, liquid fuel was fed into the shell and existed around the conical laser guide because the surface tension of the fuel must cause it. Then, it was solidified. The laser light provided a heat source to the conical laser guide so that the solid fuel was moved to the other interior of the shell. This process resulted in missing solid fuel around the conical laser guide. To fill the vacant space, liquid fuel was added as temperature was raised to the melting point. After the liquid fuel addition, temperature was lowered to the solidification point again. During this ...
The purpose of this study is to search for a new method of dispersing spilled heavy oil, which has a detrimental effect on the natural environment and marine ecosystem. A method ejecting a waterjet vertically downward to heavy oil on the water surface was studied, particularly focusing on the effect of the guide nozzle shape. The waterjet comprised heavy oil and minute air bubbles, and passed through the hole of the guide nozzle. Thirteen guide nozzle shapes were tested and compared. The dispersion efficiency of a tapered hole was the best among the 13 nozzles. The flow in the hole of the guide nozzles was recorded by a high-speed video camera. The occurrence of two flows, regular and counter flows, was observed in the taper guide nozzle. It seemed that the counter flows generated the shearing force between the waterjet and the heavy oil layer. It is considered that the shearing ...
The authors have led development of a Standard Guide for Residential Green Buildings through the consensus process of the American Society for Testing and Materials (ASTM). The voluntary guidance document has been processed through two public peer reviews in ASTM`s E-50.06 sub-committee on the environment. The guide`s purpose is to present general criteria for home builders, residential designers and developers on how to systematically approach the creation of a green home--from the design phase on through to eventual de-commissioning of residential structures. This paper briefly reviews the standards process, includes an overview of the Standard Guides` principal criteria, and provides a robust resource listing for further investigation by readers. During development of the Standard Guide, authors emphasized thorough review of the available literature on sustainable residential development. This was ...
Developing safe, reliable, cost-effective, and efficient hydrogen-electricity co-generation systems is an important step in the quest for national energy security and minimized reliance on foreign oil. This project aimed to, through materials research, develop a cost-effective advanced technology cogenerating hydrogen and electricity directly from distributed natural gas and/or coal-derived fuels. This advanced technology was built upon a novel hybrid module composed of solid-oxide fuel-assisted electrolysis cells (SOFECs) and solid-oxide fuel cells (SOFCs), both of which were in planar, anode-supported designs. A SOFEC is an electrochemical device, in which an oxidizable fuel and steam are fed to the anode and cathode, respectively. Steam on the cathode is split into oxygen ions that are transported through an oxygen ion-conducting electrolyte (i.e. YSZ) to oxidize the anode fuel. The dissociated hydrogen and residual steam are exhausted from ...
Single-crystalline nanostructures often exhibit gradients of surface (and/or interface) curvature that emerge from fabrication and growth processes or from thermal fluctuations. Thus, the system-inherent capillary force can initiate morphological transformations during further processing steps or during operation at elevated temperature. Therefore and because of the ongoing miniaturization of functional structures which causes a general rise in surface-to-volume ratios, solid-state capillary phenomena will become increasingly important: On the one hand diffusion-mediated capillary processes can be of practical use in view of non-conventional nanostructure fabrication methods based on self-organization mechanisms, on the other hand they can destroy the integrity of nanostructures which can go along with the failure of functionality. Additionally, capillarity-induced shape transformations are effected and can thereby be controlled by applied fields and forces (guided ...
Radiation protection programs for workers are based, in the United States, on a hierarchy of limitations stemming from Federal guidance approved by the President. This guidance, which consists of principles, policies, and numerical primary guides, is used by Federal agencies as the basis for developing and implementing their own regulatory standards. The primary guides are usually expressed in terms of limiting doses to workers. The protection of workers against taking radioactive materials into the body, however, is accomplished largely through the use of regulations based on derived guides expressed in terms of quantities or concentrations of radionuclides. The values of these derived guides are chosen so as to assure that workers in work environments that conform to them are unlikely to receive radiation doses that exceed the primary guides. The purpose of the present report is ...
This safety design guide for pipe rupture protection identifies high-energy systems in which pipe ruptures must be postulated to occur, as well as systems that must be protected from the dynamic effects of such ruptures. Dynamic effects considered in this SDG consist of pipe whip (including missiles generated by pipe ruptures, if any) and jet impingement, Requirements for protection against the dynamic effects of a postulated pipe rupture and method of protection of essential structures, systems and components are specified for these effects. The change status for the regulatory requirements, code and standards should be traced and this safety design guide shall be updated accordingly. 2 tabs., 5 refs. (Author) .new.
Positron-emission tomography (PET) and PET/CT (computed tomography) are becoming increasingly important for diagnosis and treatment of cancer. Clinically relevant changes can sometimes be seen on PET that are not seen on other imaging modalities. However, PET is not suitable for guiding biopsy as the images are not obtained in real-time. Therefore, our research group has begun developing a concept for PET/CT-guided interventional procedures. This paper presents the rationale for this concept, outlines our research plan, and includes an initial study to evaluate the relative sensitivity of CT and PET/CT in detecting suspicious lesions. (orig.)
It has been predicted for several years that light is focused (optically guided) as well as amplified by the electron beam in a free electron laser (FEL). The degree of focusing depends strongly on both electron beam and optical beam characteristics. In an FEL oscillator the degree of focusing varies with intracavity optical power during the macropulse. We report the first direct measurements of the evolution of transverse optical model size and shape between small signal and saturation in a short wavelength (Compton regime) FEL oscillator. The mode measurements on the Mark III FEL oscillator are shown to be consistent with theory, requiring both refractive and gain contributions to guiding. (orig.).
The book is a German translation of an American textbook with the original title ''MRI Survival Guide'' and is intended to serve as an introductory guide for beginners or a reference book for quick information. Readers will find information on the fundamentals of the technology and methodology of MRI as well as all details of relevance to practice in a precise and easy-to-grasp arrangement, covering all anatomic areas of interest, illustrations and descriptions of characteristic signs of pathologic processes, high-quality and unusually large-sized diagnostic pictures, a modern didactic concept for quick orientation, including surveys, tables, and reproductions for visualisation of contents. (orig./CB)
The author describes feasibility study on the scheme of disposing spent guide tubes at Daya Bay nuclear power plant, including scheme selection, packing cask design, disposal operation and technological process, budget estimation and safety evaluation. The research results show that the new scheme is feasible on technology, and reasonable on budget. If the scheme is adopted to dispose the spent guide tubes at Daya Bay nuclear power station, it can not only save large funds, but also accumulate experience on disposing non-compressible low and intermediate level solid radioactive wastes produced at nuclear power station for the country
This construction curriculum guide on masonry for secondary students is one of six developed for inservice teachers at Marianas High School in Saipan. The guide provides the rationale, description, goals, and objectives of the program; the program of studies and performance objectives by levels; samples of lesson plans for effective delivery of instruction; and a listing of references. Concepts covered include orientation to masonry construction, safety, tools and equipment, cement, concrete, concrete block masonry, concrete forms, and concrete reinforcement. Appended materials include transparency copies, tests and answer keys, information sheets, and student activities. (CT)
Washington's geothermal potential is discussed. The following topics are covered: exploration, drilling, utilization, legal and institutional setting, and economic factors of direct use projects. (MHR)
A guide to practical astronomy. It introduces the reader to some basic (and some not-so-basic) astronomical concepts, and discusses the stars and their evolution, the planets, nebulae, and distant galaxies
15 to 75% of the gun barrel diameter. Similarly, model masses typically vary from 0.01 to 100 .... taining acceptable levels of gun barrel erosion. The ...
... Top Ten Things You Need to Know About Global Warming and a note about why there is so ... create your own unit on climate change and global warming."...
The purpose of the recommendation is to prevent, to detect, and to remove soiling of guide and retrating blades of steam turbines, e.g. on account of foreign matter in steam dissolved. (TK/LN).
... 2. Federal Employees Retirement System (FERS) ... . 17 ... a. Straight and differential pay b. Bcnefits: retirement, sick leave, health insurance ...
There is a mismatch between the documentation of the visually guided behaviors and visual physiology of decapods (Malacostraca, Crustacea) and knowledge about the neural architecture of their...Full Text Available
... s guides and "how-to" videos and other materials, and 7. Receive continuing support from GLOBE's ... and educational materials that result from international proposals in its materials and support ...
consider applying the requirements of MIL-STD-2073-1. 5.2.5. Sustainability. Because of the design control the. Government has had over. XIL-SPEC designs, ...
BackgroundAmino-terminal signal peptides (SPs) are short regions that guide the targeting of secretory proteins to the correct subcellular compartments in the cell. They are cleaved...Full Text Available
This bibliography of nonserial publications consists of 610 annotations. It is intended as a guide to the development of a collection for librarians and for health professionals in research and education....Full Text Available
In recent years, the influences of acid rain such as the acidification of lake water, on bio-system by the heavy metals from effluent of soils with acid rain and also on the structural materials of buildings are seriously discussed. Sulfur and nitrogen that are contained in fossil fuels are released into the atmosphere by the fuel combustion as their oxides dissolve in rain drops as sulfite and nitrous ions, where they are further oxidized into sulfate and nitrate ions These ions lower the pH of rain water resulting so-called acid rain. Therefore, it is important to accurately determine these ions in rain water for the investigation of reality of acid rain. However, it is not easy to accurately determine these ions, especially for sulfite ions in rain water, since they are quickly oxidized by the catalytic action of metallic ions such as ...
There are 13 Electron Beam Ion Sources in operation which produce highly charged ions, up to Th[sup 80+] and Xe[sup 53+]. Most of the sources are used to study these ions under electron impact or when recombining with gaseous or solid targets. That provides an insight into the atomic physics of these highly charged ions and into the physics of the plasma in which such ions can be found. This paper reviews the present knowledge of atomic processes, important in the production of such ions with an EBIS.
There are 13 Electron Beam Ion Sources in operation which produce highly charged ions, up to Th{sup 80+} and Xe{sup 53+}. Most of the sources are used to study these ions under electron impact or when recombining with gaseous or solid targets. That provides an insight into the atomic physics of these highly charged ions and into the physics of the plasma in which such ions can be found. This paper reviews the present knowledge of atomic processes, important in the production of such ions with an EBIS.
The use of computer vision to detect, measure, and perhaps guide the assembly of man-made components is potentially a very significant research and development area. The efficacy of these techniques for any given application depends on both technical and economic considerations. This paper will explore both these considerations using appropriate generic examples. It is our goal to first present a concise discussion of the present state of many technical and economic factors and then extrapolate these factors into the future for the purpose of guiding further investigations.
Apppendix B of 10 CFR Part 50 establishes quality assurance requirements for the operation of nuclear power plant safety-related structures, systems and components. This Guide describes an acceptable method for complying with these regulations with regard to overall quality assurance program requirements for the operation phase of nuclear power plants. Input to this Guide has been provided by the Advisory Committee on Reactor Safeguards.
Appendix B to 10 CFR Part 50 establishes overall quality assurance requirements for the design, construction and operation of safety-related structures, systems, and components. This guide presents a method acceptable to the Commission for complying with these regulations with regard to overall quality assurance program requirements during design and construction of nuclear power plants. Input to this guide has been provided by the Advisory Committee on Reactor Safeguards.
The general requirements applicable to the quality assurance of the Finnish nuclear power plants are presented in the Council of State Decision (395/91) and in the guide YVL 1.4. This guide specifies the quality assurance requirements to be applied during the operation of the nuclear power plants as well as of the other nuclear facilities. Quality assurance applies to all the activities and organizations with a bearing on the safe operation of the nuclear power plants. (5 refs.).
Channel plasmon polaritons (CPPs) propagating along the bottom of subwavelength grooves cut into a metal surface were recently shown to exhibit strong confinement combined with low propagation loss, a feature that makes this guiding configuration very promising for the realisation of ultra-compact photonic components. Here, the results of our investigations of CPP guiding by V-grooves cut into gold are presented, demonstrating efficient large-angle bending and splitting of radiation as well as waveguide-ring resonators and Bragg grating filters.
This report is an Implementation Guide for Hanford Tanks Initiative C-106 heel retrieval contract management HNF-2511 to provide a set of uniform instructions for managing the two contractors selected. The primary objective is to produce the necessary deliverables and services for the HTI project within schedule and budget.
This 2001 edition of the guide to UK renewable companies and equipment and service providers presents summaries of the different industry sectors covering wind power, photovoltaics, solar water heating, geothermal heat pump, hydroelectric power, marine current and wave technology, bioenergy, power generation from landfill gas, energy from waste, and cogeneration. A UK company classification listing and index is provided along with listing of UK organisations and companies and an index of advertisers.
This guide is one of the actions following from the recommendations of the Thermie B project that aimed to support the development of a new European Integrated Clean Coal (CCT) Program concept (STR - 1121 - 96), November 1998. The concept aimed to enhance the market deployment of EU CCTs. This guide is prepared for EU industry to help them finding support for their CCT exports to the target markets. The guide will include easy accessible information on the most relevant EC-programs and is intended as a practical tool for EU CCT industry, to assist them in identifying and selecting the export support and programs best able to support their specific export assistance. The guide is a manual (signpost) through the 'jungle of assistance' and therefore does not include extensive information on application procedures, since this kind of information can be easily obtained, once the relevant ...
Background/AimsAlthough endoscopic ultrasound guided fine needle aspiration (EUS-FNA) has been introduced and its use has been increasing in Korea, there have not been many reports...Full Text Available
Here's the book you need to prepare for Cisco's revised CCNA exam, 640-801. This new edition of the best-selling CCNA Study Guide provides in-depth coverage of every CCNA exam objective, practical information on Cisco internetworking solutions and hundreds of challenging review questions.
CT-guided fine needle aspiration biopsy (FNAB) is known to improve diagnosis of expansive abdominal lesions, especially relative to more invasive procedure like explorative laparotomy. FNAB in not commonly use in pediatric patients because of their poor collaboration and of associated risks. The authors investigated the feasibility of FNAB in the pediatric age.
The formation of the ions charge and energy distributions of the ions slowed down or randomly changing their charge in the collisions with the medium particles are studied. The effect of the ions dispersion by the charge on the Bragg curve form is investigated. The proposed diffusion approximation for the heavy ions kinetic equation makes it possible to determine simply the parameters of the ions distribution by charge and energy on the whole way of the ions motion. The relation between the ions charge distribution characteristics and the cross sections of the ionization-recombination processes is indicated. The ions distributions, calculated in the proposed analytical model, are compared with the results of the numerical calculations. Good agreement between the analytical, numerical and experimental results is obtained
This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users Guide. The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users Guide. The Xyce Parallel Electronic Simulator has been written to support, in a rigorous manner, the simulation needs of the Sandia National Laboratories electrical designers. It is targeted specifically to run on large-scale parallel computing platforms but also runs well on a variety of architectures including single processor workstations. It also aims to support a variety of devices and models specific to Sandia needs. This document is intended to complement the Xyce Users Guide. It contains ...
While the methodology used in developing test items can vary significantly, to ensure quality examinations, test items should be developed systematically. Test design and development is discussed in the DOE Guide to Good Practices for Design, Development, and Implementation of Examinations. This guide is intended to be a supplement by providing more detailed guidance on the development of specific test items. This guide addresses the development of written examination test items primarily. However, many of the concepts also apply to oral examinations, both in the classroom and on the job. This guide is intended to be used as guidance for the classroom and laboratory instructor or curriculum developer responsible for the construction of individual test items. This document focuses on written test items, but includes information relative to open-reference (open book) examination test items, as well. These ...
The purpose of the study is to investigate the heat transfer augmentation method for a wavy channel type heat exchanger. Experimental studies were carried out, by installation of flow guide-plates with simple structure, to clarify the effects on the augmentation whether the effects are brought by the flow acceleration or by the increase of intensity of turbulence due to the flow seperation, and to determine optimum shape of flow guide-plates. The shape and dimensions of the experimental apparatus are as follows; channel width H of 30 mm, rectangular section with breadth of 300 mm, wavy duct with a bend angle of 60/sup 0/ and straight pipe of 2H length. Air stream was flowed through the duct with Reynolds number of 1.7 x 10/sup 4/ only. As the results, following conclusions were obtained. (1) Wavy duct with large bend angle and without inserting flow guide-plates could not be expected large effects on the heat transfer ...
A nonneutral /sup 7/Li/sup +/ ion plasma is described in which ion Langmuir waves are observed for the first time. The properties of these waves near the Brillouin density limit are investigated.
The properties of negative-ion beams are very important for designing negative-ion apparatus and applications of negative-ion beams, especially, electron detachment cross-sections at the interaction between negative-ion beams and gas particles in the transport system, and secondary-electron emission factors when negative ions are incident on solid surfaces. These properties of negative-ion beams were investigated experimentally as a function of the ion energy under 50 keV. The single electron detachment cross-sections are almost constant in the other of 10[sup -15] cm[sup 2] in this energy range, but double electron detachment cross-sections increase in proportion to the ion velocity and much smaller than the single one. As for the secondary-electron emission factor, the emission factors for ...
The properties of negative-ion beams are very important for designing negative-ion apparatus and applications of negative-ion beams, especially, electron detachment cross-sections at the interaction between negative-ion beams and gas particles in the transport system, and secondary-electron emission factors when negative ions are incident on solid surfaces. These properties of negative-ion beams were investigated experimentally as a function of the ion energy under 50 keV. The single electron detachment cross-sections are almost constant in the other of 10"-"1"5 cm"2 in this energy range, but double electron detachment cross-sections increase in proportion to the ion velocity and much smaller than the single one. As for the secondary-electron emission factor, the emission factors for negative-ion ...
Abstract in english AIM: This prospective randomized clinical study was conducted to compare radioguided occult lesion localization (ROLL) with wire-guided localization to evaluate optimum localization techniques for non-palpable breast lesions. METHODS: A total of 108 patients who were undergoing an excisional biopsy for non-palpable breast lesions requiring pathologic diagnosis were randomly assigned to the ROLL group (n = 56) and wire-guided localization group (n = 52). In the study, pati (more) ents' characteristics, radiological abnormalities, radiological technique of localization, localization time, operation time, weight of the excised specimen, clearance margins, pathological diagnosis and perioperative complications were assessed. RESULTS: There were no differences between the two groups in terms of age, radiological abnormalities and localization technique (p = non-significant for all). ROLL techniques resulted in 100% retrieval of ...
Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of ...
This user's guide describes BNW-III, a computer code developed by the Pacific Northwest Laboratory (PNL) as part of the Dry Cooling Enhancement Program sponsored by the US Department of Energy (DOE). The BNW-III code models a modular dry/wet cooling system for a nuclear or fossil fuel power plant. The purpose of this guide is to give the code user a brief description of what the BNW-III code is and how to use it. It describes the cooling system being modeled and the various models used. A detailed description of code input and code output is also included. The BNW-III code was developed to analyze a specific cooling system layout. However, there is a large degree of freedom in the type of cooling modules that can be selected and in the performance of those modules. The costs of the modules are input to the code, giving the user a great deal of flexibility.
Purpose Skilled placement of peripherally inserted central catheters (PICC) has a profound impact on patient well-being and costs of care. The use of ultrasound-guided methods and prescribed training for cannulation skills are evidence-based practice recommendations. The purpose of this study was to compare two methods of PICC instruction on the acquisition of applied skills. Methods Residents were randomly assigned to one of two groups (N?=?16/16) of this blind-rater study and were trained to perform ultrasound-guided PICC cannulation using either simulation or apprenticeship methods. All residents were assessed placing a PICC in applied clinical patient care. Results Residents who completed simulation training had significantly better transfer of skills to applied clinical practice than ...
A quantum mechanical analysis of the guided light in integrated photonics waveguides is presented. The analysis is made starting from one-dimensional (1D) guided vector modes by taking into account the modal orthonormalization property on a cross section of an optical waveguide, the vector structure of the guided optical modes and the reversal-time symmetry in order to quantize the 1D vector modes and to derive the quantum momentum operator and the Heisenberg equations. The results provide a quantum-consistent formulation of the linear and nonlinear quantum light propagations as a function of forward and backward creation and annihilation operators in integrated photonics. As an illustration, an application to an integrated nonlinear directional coupler is given, that is, both the nonlinear momentum and the Heisenberg equations of the nonlinear coupler are derived.
This guide is intended to provide the necessary guidance to successfully manage the NAVMED Navy Occupational Health Information Management System (NOHIMS) at NAVMED sites and the NAVSEA Occupational Safety and Health Record Keeping System (OSHRKS) at NAVSEA sites. Outlines procedures to manage system operations, procedures to resolve hardware, software and communications problems, and procedures outside the realm of system operations that are required for a successful system. This guide is intended for the System and Functional Managers use. The System Manager is the individual designated to provide overall ADP management to the entire local configuration. Usually responsible for file backup, daily operations of the CPU, security, supplies, equipment, operating software and technical ADP guidance to the local functional users.
Coronary angiography has provided an unrivalled appreciation of coronary anatomy fostering a far greater appreciation of the extent of atherosclerotic disease. However, the subjectivity of coronary angiography at determining the extent of plaque has been exposed with IVUS. Indices of coronary physiology have provided valuable adjunctive information as to the physiological importance of specific lesions. Fractional flow reserve is an established method for evaluating the significance of epicardial stenoses. Fractional flow reserve guided percutaneous coronary intervention is associated with improved outcomes when compared to a conventional angiographic guided strategy, particularly in intermediate lesions. The use of coronary physiology in the cath lab represents a new avenue to guide appro...
Purpose: To flatten temperature distribution of coolant within a core. Constitution: The control device of the present invention is to vary reactivity of a fast breeder to control a reactor power. In general, the control device of this kind comprises a guide pipe arranged within the core and a control rod movable up and down within the guide pipe, and a coolant flows from bottom toward top within the guide pipe. Since a cooling flow rate has a margin, temperature of coolant outlet is extremely low as compared to a fuel assembly, and therefore temperature gradient in the vicinity of the top of the control rod becomes sharp to possibly impart thermal shock to the structural material. In the present invention, the flow passage of coolant is varied to thereby avoid outflow thereof into the core, thus flattening the temperature distribution of the coolant within the core. (Kamimura, M.).
Spatial skills are a central component of intellect and show marked individual differences. There is evidence that variations in the spatial language young children hear, which directs their attention to important aspects of the spatial environment, may be one of the mechanisms that contributes to these differences. To investigate how play affects variations in language, parents and children were assigned to 1 of 3 conditions: free play with blocks, guided play, or play with preassembled structures (Study 1). Parents in the guided play condition produced significantly higher proportions of spatial talk than parents in the other two conditions, and children in the guided play condition produced significantly more spatial talk than those in the free play condition. Study 2 established baseli...
We show that the HACCP system is not fully applicable at the primary production level, and that food safety is obtained through the careful implementation of good hygiene practice (GHP) at the farm. Guides to GHP intended at primary productions cover one activity, such as cattle rearing or corn production. Yet most farms have more than one activity. Hazards from one activity can be transferred to another activity, and in general this is not considered in one-activity guides. There is a need therefore for farmers to be able to detect and control such transfers. We suggest a horizontal complement to the Guides to GHP that would consider only the application of the Step 6 and Principle 1 of the HACCP system amended as follows: ''List all potential hazards transferred from one activity to anot...
Taking the development of large current, negative ion sources which is in progress aiming at nuclear fusion reactors and the development of high luminance ion sources planned as a part of the Omega Project as the examples, the technology for generating high power ion beams is explained. Both these projects are positioned at the limit of the present technology of high power ion beam application as their targeted beam power reaches several tens MW. Consequently, the requirement for the ion sources is severe, and in particular, the generation of the ion beams having large current density with good convergence is beyond all precedents. The application of high power ion sources has been realized as the neutral beam injectors for large tokamaks. Also the hydrogen negative ion source of large current and the electrostatic ...
Femur fractures typically affect elderly patients with multiple co-morbidities. Pain control can be difficult, requiring intensive nursing and physician care as elderly patients may manifest cardiovascular...Full Text Available
Randomized clinical trials are designed with stopping boundaries to guide data monitoring committees with their decision making concerning ongoing trials. In particular, when extremely positive results...Full Text Available
The likelihood that past experience will produce correct guides to current practice depends on the signal-to-noise ratio for the clinical problem of interest. If the signal-to-noise ratio is high, the...Full Text Available
Papers are presented in the areas of: Medical Technologies; Non-Destructive Evaluation; Applications of Signal/Image Processing; Laser Guide Star and Adaptive Optics; Computational Electromagnetic, Acoustics and Optics; Micro-Impulse Radar Processing; Optical Applications; TANGO Space Shuttle.
This article focuses on results of the systematic review from the Guide for Useful Interventions for Activity in Latin America project related to school-based...Full Text Available
A robust technique for determining the principal axes of a 3D shape represented by a point set, possibly with noise, is presented. We use techniques from robust statistics to guide the classical...Full Text Available
ObjectivesWe have developed an image-guided surgery system based on invisible near-infrared (NIR) fluorescent light. Presently, the only clinically-available NIR...Full Text Available
Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a...Full Text Available
This guide describes an acceptable method of complying with the Commission's regulations with regard to the quality assurance requirements for the packaging, shipping, receiving, storage, and handling of items for water-cooled nuclear power plants.
The guide describes a method acceptable to the NRC staff for complying with the Commission's regulations with regard to quality assurance requirements for installation, inspection, and testing of mechanical equipment and systems for water-cooled and high-temperature gas-cooled nuclear power plants.
Chest compression-only (CC-only) is now incorporated in the Norwegian protocol for dispatch guided CPR (cardiopulmonary resuscitation) in cardiac arrest of presumed cardiac aetiology.We present...Full Text Available
The development of three-dimensional (3D) biomimetic scaffolds which provide an optimal environment for cells adhesion, proliferation and differentiation, and guide new tissue formation has...Full Text Available
PurposeAuto-propagation of anatomical region-of-interests (ROIs) from the planning CT to daily CT is an essential step in image-guided adaptive radiotherapy. The...Full Text Available
To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored continuously with 3-D ...
Cancer immunotherapies can be guided by cellular imaging techniques, which can identify the presence or absence of immune-cell accumulation in the tumor tissue in-vivo and in real time. This...Full Text Available
Pyrethroid insecticides have been extensively used in China and worldwide for public health pest control. Accurate resistance monitoring is essential to guide the rational use of insecticides and resistance...Full Text Available
Scientific knowledge of human health continues to grow substantially through publication in empirical journals. These journals, which serve as the warehouses of scientific knowledge, continue...Full Text Available
Metacad is a collection of routines which creates a randomly accessible data structure from Applicon's APPLE-3D data format and supplies a logical method for manipulation of the data structure by a CAD application program.
BackgroundPlant biologists have long speculated about the mechanisms that guide pollen tubes to ovules. Although there is now evidence that ovules emit a diffusible attractant, little...Full Text Available
The October 2000 terrorist attack on the guided-missile destroyer USS Cole (DDG 67) in the port of Aden, Yemen, is commonly viewed in the larger context of al-Qa'ida's September 11th campaign. Beyond the initial official investigations, the military force...
Laboratory studies were performed to support field-testing of base injection into the F-Area Seepage Basins groundwater. The general purpose of these experiments is to provide information to guide the test of base injection and to identify potential adverse effects.
Percutaneous coronary intervention can be associated with distal embolization of thrombotic material causing myocardial necrosis and infarction.We discuss the role of intravascular imaging to...Full Text Available
Empirical treatment is best guided by current surveillance of local resistance patterns. The goal of this study is to characterize the prevalence of antimicrobial nonsusceptibility within pneumococcal...Full Text Available
Objective:To assess the efficacy of facet joint infiltrations for pain relief in 44 selected patients with chronic nonradicular low back pain (LBP).Materials...Full Text Available
SummaryConvection-enhanced delivery (CED) of substances within the human brain is becoming a more frequent experimental treatment option in the management of brain tumors, and...Full Text Available
Orientation and movement relies on both visual and vestibular information mapped in separate coordinate systems. Here, we examine how coordinate systems interact to guide eye movements of rabbits....Full Text Available
Experience has shown that a list of tips provides designers and engineers with an effective guide in their areas of duties and concern. This list contains new and rare information on heat exchangers and heat recovery systems. The information presented can be used effectively with personal computers and pocket calculators and also conveniently translated into computer programs and nomographs.
The Vision for Space Exploration will guide NASA's future human and robotic space activities. The broad range of human and robotic missions now being planned will require the development of new system-level capabilities enabled by emerging new technologie...
Many animals use the spectral distribution of light to guide behaviour, but whether they have colour vision has been debated for over a century. Our strong subjective experience of colour and the fact...Full Text Available
When choosing an electromagnetic tracking system (EMTS) for image-guided procedures several factors must be taken into consideration. Among others these include the system’s refresh rate, the...Full Text Available
Background:During transurethral resection surgery (TUR), accidental stimulation of the obturator nerve can cause violent adductor contraction, leading to serious intraoperative...Full Text Available
ADD_MEAN is a floating point number. This value is only used for the LEE filter, ... an averaging filter. This value is only used for the Frost filter, ...... Use this keyword to specify the gaussian sigma value for methods 4 and 5. For ...
There are many requirements for cost analysis and estimating within the Department of Energy (DOE). As projects go through the many stages of planning, source evaluation and selection, contracting, and construction, different estimating requirements exist and different techniques are available to the estimator. This cost guide illustrates how quantity takeoff estimating is performed when adequate design data are available, and it shows how statistics can be applied to obtain parametric cost estimates. Parametric techniques will become increasingly useful as the Department's cost data base and Cost Estimating Relationships (CERs) are developed. Other cost guides developed by the Independent Cost Estimating (ICE) Staff will be published and disseminated soon. The section on parametric cost estimating uses Department of Defense examples since the ICE Staff considered this information to be some of the best available on this subject. Also, ...
Detectors for a photon-photon collider are envisaged using as guide-lines the physics goals and the interaction point environment. Production of SUSY Higgs scalar and pseudo-scalar is emphasized. Some aspects of the interaction point environment are discussed. ((orig.)).
The extensive diversity of Plasmodium falciparum antigens is a major obstacle to a broadly effective malaria vaccine but population genetics has rarely been used to guide vaccine design....Full Text Available
The overarching goal of medical training is to nurture the growth of knowledgeable, caring and insightful clinicians guided by the ideals of medical professionalism. Recent definitions of professional...Full Text Available
This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of cavitation influences the valve and system. Examples are included to ...
Catheter ablation is a first line treatment for many cardiac arrhythmias and is generally performed under x-ray fluoroscopy guidance. However, current techniques for ablating complex arrhythmias such...Full Text Available
This regulatory guide describes methods acceptable to the NRC staff for calculating radon fluxes through earthen covers and for calculating the resulting minimum cover thickness needed to meet NRC and EPA standards. The guide also suggests methods for obtaining the various parameters used in calculating the radon fluxes and earthen cover thicknesses and suggests default values for certain parameters. This regulatory guide is applicable to active uranium tailings sites. The NRC staff is using the methods stated in this guide as a basis for review and concurrence of DOE remedial action plans for inactive sites. The guidance is intended to be used for calculating radon flux attenuation by earthen uranium mill tailings covers. The parameter values and examples presented are limited to earthen cover materials, but the diffusion theory and the methods presented are also applicable to man-made materials. ...
This regulatory guide describes methods acceptable to the NRC staff for calculating radon fluxes through earthen covers and for calculating the resulting minimum cover thickness needed to meet NRC and EPA standards. The guide also suggests methods for obtaining the various parameters used in calculating the radon fluxes and earthen cover thicknesses and suggests default values for certain parameters. This regulatory guide is applicable to active uranium tailings sites. The NRC staff is using the methods stated in this guide as a basis for review and concurrence of DOE remedial action plans for inactive sites. The guidance is intended to be used for calculating radon flux attenuation by earthen uranium mill tailings covers. The parameter values and examples presented are limited to earthen cover materials, but the diffusion theory and the methods presented are also applicable to man-made materials. ...
Part one of this study investigated the effect of aging on social-cognitive characteristics related to physical activity (PA) among adults in the baseline phase of a health promotion...Full Text Available
BackgroundHip surface replacement arthroplasty (SRA) can be an alternative for total hip arthroplasty. The short and long-term outcome of hip surface replacement arthroplasty mainly...Full Text Available
Fate maps are generated by marking and tracking cells in vivo to determine how progenitors contribute to specific structures and cell types in developing and adult tissue. An advance in this...Full Text Available
... Birdsall, DH, Ford, FC, Furth, HP, and Riley, RE, A-2-3-1 "Magnetic Forming! What is it?", American Machinist, 105 (6), 117-121 (March 20, 1961). ...
Prepared by volunteers representing a wide range of interests and experience and including students with disabilities, this guide provides basic information about support services available to students with disabilities at public and private postsecondary education institutions in the State of Washington. The guide may also serve as a resource for family members, school counselors and others who assist students in furthering their education. The first section presents general information, discussing students' rights to appropriate education, giving basic rules for managing the transition to college life, charting effects of functional limitations in the academic setting, and providing a planning checklist for new students. Institutional profiles are presented in the second section, covering vocational-technical institutes (5), community colleges (27), and 4-year colleges and universities (16). Information is included on contact person, ...
Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available
...Colormetric System, which lie within the region bounded by the spectrum locus and lines defined by the following equations: X...intensity of a light in candela as defined by the Illuminating Engineering Society's Guide for Calculating the Effective...
... (v) Import onto or keep on Wake Island any plant or animal not indigenous to the island, other than military working dogs or a guide dog for the blind or visually-impaired accompanying its owner; or (w) Import or bring onto or...
...1) A privately owned motor vehicle. (2) A privately owned boat. (3) An indigenous animal, military working dog, or guide dog for the blind or visually-impaired accompanying its owner. (4) A narcotic or dangerous drug or...
Negative ion based neutral beam injector is one of the most attractive heating system in future fusion reactors. In realizing the system, the crucial device which has to be developed is a high intensity negative ion source. Significant progress has been made on the negative ion source in these years. Among them, a few ampere negative ion beam were produced stably, while the divergence of negative ion beams becomes to be as low as < 10 mrad. We consider these results are demonstrating the potential of the negative ion source for the heating device in future reactors.
A brief overview is given of the geological characteristics of each region of the state as they relate to potential geothermal development. Those exploration methods which can lead to the siting of a deep exploration well are described. Requirements and techniques needed for drilling deeper higher temperature exploration and production wells are presented. Electrical generation, direct utilization, and indirect utilization are reviewed. Economic factors of direct use projects are presented. A general guide to the regulatory framework affecting geothermal energy development is provided. The general steps necessary to gain access to explore, develop, distribute, and use geothermal resources are outlined. (MHR)
The purpose of-this planning guide is to present the process used to identify, document, and control PFP Stabilization and Deactivation Project interfaces. Revisions to this document will include, as attachments, the most recent version of the Project Interface Management List. A preliminary Interface Management List is included in Appendix A. This document is intended be a Project owned management tool. As such, this document will periodically require revisions resulting from improvements of the information, processes, and techniques as now described. For most revisions that suggest improved processes, PFP management approval is all that will be required.
Cross-sectional imaging has revolutionised the radiological diagnosis of pleural collections. Not only can the precise location and volume of a pleural effusion be established, but also features specific for the aetiology of the effusion can be demonstrated. Increasingly, radiologists are called upon to perform image-guided biopsies, aspirations and small bore chest drain placement, all of which have been shown to be safe and efficacious. Pneumothoraces occurring due to acute trauma and in an intensive care setting can also benefit from radiological input, both in terms of diagnosis and image-guided treatment. (orig.)
Purpose: To prevent evaporization stills against corrosion due to radioactive liquid wastes. Constitution: Microwaves are supplied from a microwave generator by way of a wave guide tube and through a microwave permeation window to the inside of an evaporatization still. A matching device is attached to the wave guide tube for transmitting the microwaves in order to match the impedance. When the microwaves are supplied to the inside of the evaporization still, radioactive liquid wastes supplied from a liquid feed port by way of a spray tower to the inside of the evaporization still is heated and evaporated by the induction heating of the microwaves. (Seki, T.).
A Guide to Seismic Un{sup *} (SU)(2)-Examples of Data Processing(part 1), Data Input and the Preparation of Trace Headers - This is part 1, the preparatory section for the preliminary series for the SU, the two cases of reflectional seismic survey and processing employing the SU, which explains how to input input data from the SEG-Y format tapes and to set trace header. (NEDO)
Five nomographs have been prepared that facilitate the estimation of cover thickness and cover material volume for the Uranium Mill Tailing Remedial Action Program. Key parameters determined include the cover thickness with either a surface radon flux or a boundary radon air concentration criterion and the total volume of cover material required for two different treatments of the edge slopes. Also included in the engineering guide are descriptions and representative values for the radon source term, the diffusion coefficients and the key meteorological parameters. 16 refs., 7 figs., 2 tabs.
Effective-index approach is applied for modeling of channel plasmon polaritons (CPPs) propagating in rectangular grooves (trenches) and triangular (V-shaped) grooves in gold, accounting for the main features of CPP guiding and elucidating its underlying physics. The effective indexes of CPP modes along with the corresponding propagation lengths are calculated for different configurations and wavelengths while varying the groove depth. The results obtained allow one to identify the parameter range for realizing the single-mode CPP guiding featuring subwavelength confinement and moderate propagation loss at telecom wavelengths.
Developing in Ext GWT is a fast--paced, practical guide to quickly learning the tasks necessary in building enterprise--class Rich Internet Applications. Based around the exciting new UI library from Ajax leaders Ext JS and the latest GWT release, this book takes the reader through setup, the available widgets, and advanced custom widgets and templates, and concludes with a functional sample client--server application in less than 150 pages. Not your typical beginner's guide to programming, this book provides a rapid approach to becoming effective with leading commercial RIA tools and librarie
This publication, part of the series titled Market Guide for Steam Coal Exports from Appalachia provides information on export markets, contracts, and related matters for producers and others involved in mining, selling, and shipping Appalachian coal to foreign buyers. It also includes information on the financial institutions that provide export finance and how they are used. Senior officers of more than 40 banks ranged from the largest money center bank and a major foreign bank in New York City to small banks in Appalachia.
A complete preparation guide for the entry-level networking CCNA certification. If you're planning to advance your career by taking the all-important Cisco Certified Network Associate (CCNA), this is the study guide you need! Seven minibooks cover all the concepts and topics on which you'll be tested, covering the latest version of the exam. Each part of the exam is covered thoroughly in its own section, so you can readily find the information you want to study. Plenty of review questions help you prepare, and the companion CD-ROM includes the highly rated Dummies Test Engine so you can test y
We made Basic designs of neutron guide, choppers, and detectors in order to optimize the design parameters of DC-TOF to be built in the HANARO Cold Neutron Guide Hall. In addition, we calculated the expected performance of DC-TOF using Monte Carlo simulations and evaluated the properties of neutron beam. Based on the results we obtained, we have compared the expected performance of the DC-TOF with those of existing instruments overseas. In conclusion, we believe that we will be able to construct the DC-TOF at HANARO as one of the best instruments of its kinds and it will become an invaluable instrument to researchers in the related field.
A brief overview is given of the geological characteristics of each region of the state as they relate to potential geothermal development. Those exploration methods which can lead to the siting of a deep exploration well are described. Requirements and techniques needed for drilling deeper higher temperature exploration and production wells are presented. Electrical generation, direct utilization, and indirect utilization are reviewed. Economic factors of direct use projects are presented. A general guide to the regulatory framework affecting geothermal energy development is provided. The general steps necessary to gain access to explore, develop, distribute, and use geothermal resources are outlined. (MHR)
BACKGROUND: The urgent need for patient safety education for healthcare students has been recognised by many accreditation bodies, but to date there has been sporadic attention to undergraduate/graduate medical programmes. Medical students themselves have identified quality and safety of care as an important area of instruction; as future doctors and healthcare leaders, they must be prepared to practise safe healthcare. Medical education has yet to fully embrace patient safety concepts and principles into existing medical curricula. Universities are continuing to produce graduate doctors lacking in the patient safety knowledge, skills and behaviours thought necessary to deliver safe care. A significant challenge is that patient safety is still a relatively new concept and area of study; thus, many medical educators are unfamiliar with the literature and unsure how to integrate patient safety learning into existing curriculum. DESIGN: To address this gap and provide a foothold for ...
BACKGROUND: The urgent need for patient safety education for healthcare students has been recognised by many accreditation bodies, but to date there has been sporadic attention to undergraduate/graduate medical programmes. Medical students themselves have identified quality and safety of care as an important area of instruction; as future doctors and healthcare leaders, they must be prepared to practise safe healthcare. Medical education has yet to fully embrace patient safety concepts and principles into existing medical curricula. Universities are continuing to produce graduate doctors lacking in the patient safety knowledge, skills and behaviours thought necessary to deliver safe care. A significant challenge is that patient safety is still a relatively new concept and area of study; thus, many medical educators are unfamiliar with the literature and unsure how to integrate patient safety learning into existing curriculum. DESIGN: To address this gap and provide a foothold for ...
We wanted to assess the usefulness of four-dimensional (4D) ultrasonography (US), i.e., real-time three-dimensional US, as an adjunct for performing various US-guided interventional procedures in superficial lesion. Thirty-three patients were referred for US-guided interventional procedures for superficial lesions, including core biopsy in 19, fine- needle aspriation in eight, therapeutic drug injection in four and needle puncture in two. The procedures were performed under 4D US guidance. We reviewed the pathologic/cytologic results of the core biopsies or needle aspirations, and also the outcomes of drug injection or needle puncture. For all the patients who underwent 4D US-guided core biopsy, the specimens were adequate for making the pathological diagnosis, and specimens were successfully obtained for those patients who underwent 4D US-guided aspiration. The patients treated with 4D ...
Ion desorption from a condensed gas solid Ne impacted by singly- and multiply-charged Ar"q"+ ions (q = 1-7) has been investigated. Various secondary ions such as cluster ions, Ne"+_n (n = 2-20) as well as atomic ions are observed. Mass spectral patterns, thickness dependence of the yields, and kinetic energy distributions of the desorbed Ne"+_n (n = 1,2) depend strongly on the projectile charge state. These results indicate that the dissipation of the projectile potential energy on the surface leads to the desorption of the monomer and small cluster ions by a Coulomb repulsion between adjacent target ions.
The desire to study negative ion structure and negative ion-photon interactions has spurred the development of ion sources for use in research and industry. The many different types of negative ion sources available today differ in their characteristics and abilities to produce anions of various species. Thus the importance of choosing the correct type of negative ion source for a particular research or industrial application is clear. In this study, the results of an investigation on the production of beams composed of negatively-charged rare-earth ions from a cylindrical-cathode-geometry, cesium-sputter-type negative ion source are presented. Beams of atomic anions have been observed for most of the first-row rare-earth elements, with typical currents ranging from hundreds of picoamps to several nanoamps.
The electrochromatographic behavior of 25 metal ions on zirconium tungstate-impregnated papers is described. Six background electrolytes were used. On the basis of the differential mobilities of metal ions which depend on the ion-exchange properties of zirconium tungstate and the nature of complex formation with the electrolytes, some important binary and ternary separations have been achieved.
The main physical processes allowing negative ion production by surface sputtering for further acceleration in tandem acceleration are briefly reviewed. The sputtering yield and the probability of negative ion ejection are discussed. The properties of negative ion beams for an efficient acceleration in tandem accelerators are also discussed, with an emphasis on space charge problems. The main features and performances of the heavy negative ion injector of the Bucharest tandem accelerator are given.
Operation at ITER specifications of the Kamaboko III ion source for 1000 second pulses of deuterium negative ion beams is underway on the MANTIS test stand. Efficient production of negative ions at low arc power requires injection of cesium into the source, temperature control of the plasma grid, and a period of conditioning of several days. Two different concepts of temperature regulated plasma grids are currently being tested. (author)
We have undertaken a study of ion mobility resolution in a miniature ion mobility spectrometer with a drift channel 1.7 mm in diameter and 35 mm in length. The device attained a maximum resolution of 14 in separating ions of NO, O{sub 2}, and methyl iodine. The ions were generated by pulses from a frequency-quadrupled Nd:YAG laser. Broadening due to Coulomb repulsion was modeled theoretically and shown experimentally to have a major effect on the resolution of the miniature device.
A general expression for the current-density distribution of a focused-ion beam (FIB) in the chromatic-aberration region is set up in the form of a definite integral. With the experimentally obtained ion-energy distribution of a liquid-metal ion source, its contribution to the FIB current-density distribution is estimated. Calculated results explain the wide-exponential tail of a FIB.
A general expression for the current-density distribution of a focused-ion beam (FIB) in the chromatic-aberration region is set up in the form of a definite integral. With the experimentally obtained ion-energy distribution of a liquid-metal ion source, its contribution to the FIB current-density distribution is estimated. Calculated results explain the wide-exponential tail of a FIB.
The apex dimensions and length are calculated as a function of current for the ion-emitting jet in liquid-metal ion sources (LMIS). The results agree well with observations. Since the final expressions are analytical, they give more insight into the fundamental mechanisms involved than do numerical calculations. Some implications of the model are discussed concerning focused ion beam (FIB) systems employing LMIS. (author).
Ion-channels can be activated (gated) by a variety of stimuli including chemicals, voltage, mechanical force or temperature. Whereas molecular mechanisms of ion-channel gating by chemicals and...Full Text Available
The estimation of numerical values of the mean distance of closest approach of ions, a, of alkaline-earth metal ion salts in aqueous solutions, determined from activity coefficients, as well as from different theoretical approaches, is presented and discussed.
The performance of the PSI/ETH focused ion beam (FIB) system has been improved to produce ion beams of very low energies down to 40 eV with a reasonable spot size of 1 {mu}m at 200 eV. (author) 2 figs., 1 ref.
The Holifield Radioactive Ion Beam Facility (HRIBF) now under construction at the Oak Ridge National Laboratory will use the 25-MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility; the choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. A high-temperature version of the CERN-ISOLDE positive ion source has been selected and a modified version of the source designed and fabricated for initial use at the ...
The Holifield Radioactive Ion Beam Facility (HRIBF) now under construction at the Oak Ridge National Laboratory will use the 25-MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility; the choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. A high-temperature version of the CERN-ISOLDE positive ion source has been selected and a modified version of the source designed and fabricated for initial use at the ...
Despite prolonged scientific efforts to unravel the hydration structures of ions in water, many open questions remain, in particular concerning the existences and structures of ion clusters in 1∶1...Full Text Available
The dependences of kinetic energies and peak profiles of multicharged ions of I "q"+ (q = 2-3) and C"2"+ on the laser intensity have been studied in detail by time-of-flight mass spectrometry, those multicharged ions are produced by irradiation of methyl iodide cluster beam with a nanosecond 532 nm Nd-YAG laser. Our experiments show that the kinetic energies released of multicharged ions increase linearly with the laser intensity in the range of 3 x 10"9-2 x 10"1"1 W/cm"2. The peaks of multicharged ions are split to forward ions and backward ions, and the ratio of the backward ions to forward ions decreases exponentially with laser intensity. The decreasing of backward ions is probably due to Coulomb scattering by the heavier I"+ ions when they turn around through the laser focus ...
The Control Rod Drive(CRD) nozzles for PWR nuclear power plants(NPP) house the control rod drives. The number of nozzle penetrations range from the mid-30's to over 100 in each reactor head. The integrity of CRD nozzles is very important, because the primary pressure boundary is established with the J-groove weld joining the nozzle to the head clad surface. The Alloy 600 PWSC CRD nozzle leaks discovered in the fall of 2000 and spring of 2001 in several US plants. Therefore the NRC has recommended a more proactive effort by US utilities to inspect similarly susceptible nozzles in all US plants. The primary safety concern is circumferential cracks that can permit the nozzles to separate from the head at high velocity and produce a large-break leak in the reactor vessel. A secondary concern is head leakage from any through-wall cracks in the nozzle or J-groove weld area. Numerous inspection and repair tools have been developed to address CRD nozzle inspection and repair issues. ...
The mechanism of abrupt increase of the giant magneto impedance (GMI) ratio in the ion irradiated Co-based amorphous ribbon has been investigated. The grazing incident X-ray diffraction and transmission electron microscope were used to characterize the samples before and after ion irradiation. The GMI-ratio considerably increased in the ion irradiated samples and the GMI response showed strong dependence on the driving frequencies. The Barkhausen noise (BN) signals are increased for the Ar ion irradiated sample with dose of 1x10^1^7 ion/cm^2. The results are interpreted in terms of GMI variation associated with domain wall dynamics.
This book is a compliation and analysis of discussions of phenomena important to ion beams and high perveance ion beams. This text discusses physics essential to research on ion beam generation and propagation and provides some requisite background to understanding the criteria for designing electrodes. Ion sources are categorized in terms of their configurations, and the relationships between various types of sources is developed. Covers collisionless space charge phenomena, collisionless plasmas, collisional effects and the taxonomy of high poissance beams. Chapters also treat the field of intense negative ion beams.
In aqueous solutions, dissolved ions interact strongly with the surrounding water, thereby modifying the solution properties in an ion-specific manner. These ion-hydration interactions can be accounted for theoretically on a mean-field level by including phenomenological terms in the free energy that correspond to the most dominant ion-specific interactions. Minimizing this free energy leads to modified Poisson-Boltzmann equations with appropriate boundary conditions. Here, we review how this strategy has been used to predict some of the ways ion-specific effects can modify the forces acting within and between charged interfaces immersed in salt solutions.
An improved ion funnel design is disclosed that decreases the axial RF (parasite) fields at the ion funnel exit. This is achieved by addition of one or more compensation electrodes after the conductance limit electrode. Various RF voltage profiles may be applied to the various electrodes minimizing the parasite axial potential wells. The smallest RF aperture that serves as the conductance limiting electrode is further reduced over standard designs. Overall, the ion funnel improves transmission ranges of both low m/z and high m/z ions, reducing RF activation of ions and decreasing the gas load to subsequent differential pumping stages.
Analytical and numerical calculations are presented for a reflexing electron beam type of collective ion accelerator. These results are then compared to those obtained through experiment. By constraining one free parameter to experimental conditions, the self-similar solution of the ion energy distribution agrees closely with the experimental distribution. Hence the reflexing beam model appears to be a valid model for explaining the experimental data. Simulation shows in addition to the agreement with the experimental ion distribution that synchronization between accelerated ions and electric field is phase unstable. This instability seems to further restrict the maximum ion energy to several times the electron energy.
A new scheme of the longitudinal emittance measurement for high energy negative ion beam is proposed. The energy distribution of the detached electron from the negative ions by the photodetachment process, if the photon energy is almost equal to the electron binding energy of the negative ion (=electron affinity of the atom), reflects that of the original negative ions. Therefore, by introducing the photon in a short width comparing with the bunch width of the negative ion beam, the longitudinal energy distribution of each phase of the beam, that is the longitudinal emittance, can be measured. (author).
This report discusses the experimental setup of experiment 814 at Brookhaven AGS. This experiment involves the collision of silicon ions with target nuclei. The detector systems are discussed primarily. (LSP)
A specific radiochemical procedure for indium determination in semiconductor-grade silicon, using an inorganic ion exchanger (cerium oxalate) is proposed.
The energy level schemes of tin isotopes produced in the heavy ion reactions are presented. The using of #gamma# spectroscopy technique is also described. 4 refs, 12 figs.
The present conference discusses plasma-assisted surface coating/modification processes, the applications to date of ion nitriding, the effects of nitrogen on metal surfaces, ion nitriding mechanisms in Cr, Al and Cr + Al-containing 1040 steel, ion nitriding of Al and its alloys, life enhancement for forging dies, novel anode plasma nitriding developments, and a comparative study of the pulsed and dc ion-nitriding behavior in specimens with blind holes. Also discussed are the influence of heating method on ion nitriding, surface hardening of marage steels by ion nitriding without core hardness reduction, plasma nitriding of nodular cast iron sput gears, NbN composites for superconductors, the carburization of tungsten in a glow discharge methane plasma, economic considerations concerning plasma nitriding, and the corrosion properties obtained by ...
Synthesis of wild-type Neurospora crassa assimilatory nitrate reductase is induced in the presence of nitrate ions and repressed in the presence of ammonium ions. Effects of several...Full Text Available
An overview of different Ion Beam Analysis (IBA) techniques is given. Examples of applications of the PIXE techniques to various types of samples are presented. (author)
The first long pulse production of high power D"- ion beams has been demonstrated in the JT-60 U negative ion sources, each of which was designed to produce 22 A, 500 keV D"- ion beams. Voltage holding capability and the grid power loading were examined for long pulse production of high power D"- ion beams. From the correlation between voltage holding and the light intensity of cathodoluminescence from the Fiber Reinforced Plastic insulators, the acceleration voltage for stable voltage holding capability was found to be less than 320-340 kV where the light was sufficiently suppressed. By tuning the extraction voltage, the grid power loadings in the ion sources were decreased to the allowable levels for long pulse injection without a significant reduction of the beam power. After tuning the acceleration and extraction voltages, D"- ion beams of 12.5 and 9.8 A ...
The purpose of this study was to evaluate the usefulness of a multifunctional gastrointestinal coil catheter for stent placement in 98 patients with colorectal strictures. The catheter was used in 98 consecutive patients for stent placement in the rectum (n = 24), recto-sigmoid (n = 13), sigmoid (n = 38), descending (n = 6), transverse (n = 11), splenic flexure (n = 3), hepatic flexure (n = 2), and ascending (n = 1) colon. The catheter was made of a stainless steel coil (1.3 mm in inner diameter), a 0.4-mm nitinol wire, a polyolefin tube, and a hemostasis valve. Usefulness of the catheter was evaluated depending on whether the catheter could pass a stricture over a guide wire and whether measurement of the stricture length was possible. The passage of the catheter over a guide wire beyond the stricture was technically successful and well tolerated in 93 (94.9%) of 98 patients. In the failed five patients, it was not possible to negotiate the ...
Laser guide star systems based on Rayleigh scattering require some means to deal with the flash of low altitude laser light that follows immediately after each laser pulse. These systems also need a fast shutter to isolate the high altitude portion of the focused laser beam to make it appear star-like to the wavefront sensor. We describe how these tasks are accomplished with UnISIS, the Rayleigh laser guided adaptive optics system at the Mt. Wilson Observatory 2.5-m telescope. We use several methods: a 10,000 RPM rotating disk, dichroics, a fast sweep and clear mode of the CCD readout electronics on a 10 $\\mu$s timescale, and a Pockel's cell shutter system. The Pockel's cell shutter would be conventional in design if the laser light were naturally polarized, but the UnISIS 351 nm laser is unpolarized. So we have designed and put into operation a dual Pockel's cell shutter in a unique bow tie arrangement.
Objective: Traditional nasolacrimal duct stenting possesses some shortcoming including difficulty of pulling ball head guide wire from the nasal cavity with turbinate hypertrophy and nasal septal deviation. The new method of nose-oral tube track establishment can overcome the forementioned and increase the successful rate. Methods: 5 F catheter and arterial sheath were modified to be nasolacrimal duct stent delivery device respectively. Antegrade dacryocystography was taken firstly to display the obstructed site and followed by the modified protocol of inserting the guide wire through nasolacrimal duct and nasal cavity, and establishing the stent delivery track for retrograde stent placement. Results: 5 epiphora patients with failure implantation by traditional method were all succeeded through the modified stenting (100%). During 6-mouth follow-up, no serious complications and reocclusion occurred. Conclusion: The establishment of ...
In the case of total skin electron therapy without the beam guide, the electron beam is scattered just outside the gantry exit, dose uniformity in the field is broken, and dose is spread outside the light field. The aims of this study were to measure the mean energy of the off-axis incident electron beam without the beam guide and to establish a reference for the clinical situation. For the measurement, a 4 MeV electron beam was selected among several energies from the linear accelerator. A scintillating fiber beam energy monitor measured the mean energy of the incident electron beam. This energy monitor is a small, light-weight piece of equipment composed of a wedge absorber, scintillation fiber, and photodiode. We found the relationship between electron energy and the indicated value of the energy monitor by means of the estimation of correction factors for five different kinds of electron energy. The preferable linear correlation of 0.997 of ...
Allowed outage time (AOT), which is required by the technical specification of nuclear power plants (NPPs), has been determined on the basis of deterministic analysis or engineering judgment. AOT is defined as the time for which safety related components can remain inoperable before a plant state is changed. Recently, plants' operating experiences and probabilistic safety assessment (PSA) results show that the AOT could be optimized. Foreign NPPs licensees have changed their technical specifications including AOT using PSA techniques. In 1998, U.S. NRC issued the regulatory guides on risk informed decision-making and technical specification changes, and these are Reg. Guide 1.174, and 1.177. The US NRC accepted AOT extension proposals including the safety injection tank (SIT) and low pressure safety injection system (LPSI) for the ABB-CE designed plants. This paper discusses interim results of AOT changes of the SIT, LPSI, CSS (Containment ...
We report coupling and guiding of pulses of peak power up to 0.3 TW in 1.5 cm long preformed plasma waveguides generated in a high repetition rate argon gas jet. Coupling of up to 52% was measured for 50 mJ, -110 fs pulses injected at times longer than 20 ns, giving guided intensities up to -5x1016 W/cm2. It was found that for short delays between waveguide generation and pulse injection, pulse shortening occurred, with this effect reduced as delay was increased. Injection into the waveguide of two consecutive pulses separated by a few nanoseconds resulted in the reduction of shortening of the second pulse at all delays. Femtosecond time-resolved shadowgrams of the coupling of injected pulses into the waveguide show that there is ?0.5 mm of neutral gas remaining at the waveguide entrance after waveguide generation.
To evaluate the diagnostic accuracy, complications, and therapeutic impact of CT-guided percutaneous core biopsies of pulmonary lesions. Material and methods: Seventy-nine patients underwent diagnostic CT-guided percutaneous core biopsies of pulmonary lesions between July 1995 and March 1999. Evaluation included corresponding clinical data, pathologic results, and therapeutic consequences. Results: There were 29 benign and 50 malignant lesions. Percutaneous core biopsy had an overall diagnostic accuracy of 95%. For malignant lesions, core biopsy was positive in 48 patients (sensitivity 96%), and for benign lesions, in 27 (sensitivity 93%). There were no false-positive findings. Pneumothoraces were observed in 19 patients (24%) and 4 of them required a chest drain (5%). There were no hematothoraces or major bleeding complications; however, postinterventional local hemorrhages were observed in 23 patients (29%). No hemoptysis was noted. ...
Aim: To evaluate the role of computed tomography (CT) in needle placement for ganglion impar blocks, and to determine the efficacy of CT-guided ganglion impar blocks in the management of coccydynia. Materials and methods: The results of ganglion impar blockade in eight patients with coccydynia secondary to trauma or unknown cause were reviewed. The diagnosis of coccydynia was based on clinical history, location of pain, and response to previous diagnostic and therapeutic procedures. The eight patients were treated with CT-guided ganglion impar blocks to manage their coccyx pain after conservative procedures, including oral medication and cushions, failed to provide relief. All patients were subjected to ganglion impar blocks under a thin-section CT-guided technique for needle placement, using a mixture of bupivacaine and triamcinolone. The patients were followed-up for a period of 6-months. Results: Eight patients were ...
The Plasma and Ion Source Technology Group at the Lawrence Berkeley National Laboratory have been developing rf-driven ion sources for the last two decades. These sources are being used to generate both positive and negative ion beams. Some of these sources are operating in particle accelerators such as the Spallation Neutron Source (SNS) at Oak Ridge, while others are being employed in various industrial ion beam systems. There are four areas where the rf-driven ion sources are commonly used in industry. (1) In semiconductor manufacturing, rf-driven sources have found important applications in plasma etching, ion beam implantation, and ion beam lithography. (2) In material analysis and surface modification, miniature rf-ion sources can be found in focused ion beam systems. They can provide ...
Neutral beam systems for the next generation of magnetic fusion devices will be based on negative ions. Development are progressing steadily, and large negative ion-based systems are prepared for JT60-U and LHD, and are being considered for ITER. An overview of the physics of the production, acceleration and neutralization of large negative ion beams is given. the present state of the art in Research and Development is also surveyed. (author). 55 refs., 10 figs., 1 tab.
Neutral beam systems for the next generation of magnetic fusion devices will be based on negative ions. Developments are progressing steadily, and large negative ion-based systems are under preparation for JT60-U and LHD, and are being considered for ITER. An overview of the physics of the production, acceleration and neutralization of large negative ion beams is given. The present state of the art in R and D is also surveyed. (Author).
A summary of the topics covered in papers presented at the 1995 Brookhaven joint conference on production, neutralization, and application of negative ion beams is given. The conference topics covered included plasma ion sources, plasma seeding of these sources for increased ion production, beam extraction and transport, computer simulation and design studies, and operation of existing and experimental ion source facilities. Application of the sources to accelerator, tokamak, and thin film deposition are discussed. (AIP) {copyright} {ital 1996 American Institute of Physics.}
The Holifield Radioactive Ion Beam Facility now under construction at the Oak Ridge National Laboratory will use the 25 MV tandem accelerator for the acceleration of radioactive ion beams to energies appropriate for research in nuclear physics; negative ion beams are, therefore, required for injection into the tandem accelerator. Because charge exchange is an efficient means for converting initially positive ion beams to negative ion beams, both positive and negative ion sources are viable options for use at the facility. The choice of the type of ion source will depend on the overall efficiency for generating the radioactive species of interest. Although direct-extraction negative ion sources are clearly desirable, the ion formation efficiencies are often too low for practical consideration; for ...
The lowest excited level in Ni-like ions, 3d{sup 9}4s {sup 3}D{sub 3}, decays only via a magnetic octupole (M3) decay. They present calculated values of transition wavelengths and rates for ions with 30 {le} Z {le} 100. They have observed this line in Xe{sup 26+}, using the Livermore EBIT-I electron beam ion trap and a microcalorimeter, as well as a high-resolution flat-field grating spectrometer.
Negative ion intensities of over 3 x 10/sup 5/ A/m/sup 2/ at energies of 2 MeV have been measured in a magnetically insulated transmission line. This negative ion production can affect the power flow in multiterawatt pulsed power devices, and may also have applications in the generation of high-intensity neutral or negative ion beams.
Focused ion beam (FIB) systems prove to be useful precision micromachining tools for a wide variety of applications. This micromachining technique includes scanning ion microscopy (SIM), micromachining by physical sputtering, and the ion-beam induced surface chemistry for etching and deposition. This technique is applied to image and modify IC's, to micromechanical applications, to modify the tip shape of tungsten emitters, and to prepare cross sections of selected regions for inspection in a transmission electron microscope (TEM). (orig.)
This report is a brief review of biological and medical applications of ion-track membranes. The review aims at informing nuclear physicists about alternative (i.e. non-fundamental-science) use of heavy ion accelerators such as production of micro- and nano-porous materials. The ion-track membranes produced this way are employed in life sciences and numerous technological applications. The author focuses on recent results from the Flerov laboratory in co-operation with other scientific institutions and industrial partners.
Results are described of the study of the analytical applicability of a highly efficient ion source developed for a mass spectrometer. Its ionizer is in the form of a partially closed cavity with a small aperture for leading out ions, heated to a high temperature. The new ion source increases the sensitivity of the apparatus in operations with transuranium elements by almost two orders of magnitude. It is possible to perform isotopic analyses with a high salt content in the sample, and to study the characteristics of nuclear fuel, even without chemical separation of the sample elements.
Heavy-ion irradiation technique has been developed for the evaluation of single-event effects on semiconductor devices. For the uniform irradiation of high energy heavy ions to device samples, we have designed and installed a magnetic beam-scanning system in a JAERI cyclotron beam course. It was found that scanned area was approximately 4 x 2 centimeters and that the deviation of ion fluence from the average value was less than 7%. (author)
Density changes in amorphous Pd{sub 80}Si{sub 20} during ion irradiation below 100K were detected by in situ HVEM measurements of the changes in specimen length as a function of ion fluence. A decrease in mass density as a function of the ion fluence was observed. The saturation value of the change in mass density was determined to be approximately -1.2%.
The paper contains a numerical evaluation of the expressions for the absorptive potential in heavy ion reactions given earlier. With a standard folding expression for the real part of the ion-ion potential general good agreement is found with experimental data for the angular distributions of elastic and inelastic scattering. Special interest is attached to the case of /sup 16/O + /sup 28/Si where the calculated imaginary potential is very small at low bombarding energies.
The paper contains a numerical evaluation of the expressions for the absorptive potential in heavy ion reactions given earlier. With a standard folding expression for the real part of the ion-ion potential general good agreement is found with experimental data for the angular distributions of elastic and inelastic scattering. Special interest is attached to the case of "1"6O + "2"8Si where the calculated imaginary potential is very small at low bombarding energies. (orig.).
Ion neoclassical transport with finite orbit width dynamics is calculated over whole poloidal cross section by using accurate {delta}f method which employs an improved like-particle collision operator and an accurate weighting scheme to solve drift kinetic equation. Ion thermal transport near magnetic axis shows a great reduction from its conventional neoclassical level due to non-standard orbit topology, like that of previous {delta}f simulation. On other hand, the direct particle loss from confinement region may strongly increase ion energy transport near the edge. It is found that ion parallel flow near the axis is also largely reduced due to non-standard orbit topology. In the presence of steep density gradient, ion thermal conductivity is significantly reduced, and an ion particle flux is driven by self-collision alone. (author)
We performed hybrid-DFT calculations for La2/3?xLi3xTiO3 (LLT) with lithium ion conductivity, in order to investigate the detailed lithium ion conductive mechanism from the viewpoint of molecular orbital (MO) method. It was concluded that the very ionic lithium ion in bottleneck accelerates the lithium ion conduction. The calculated MO shows no chemical bonding between lithium ion and other ions. In comparison with the perovskite-type trivalent titanium oxide of LaTiO3, the effect of the titanium's reduction was also investigated. We showed the possibility of the high lithium conductivity in LaTiO3.
This report reviews Soviet R and D of (1) high-intensity negative ion sources and (2) transport and focusing of negative ion beams, using Soviet open literature of the past ten years, and correlates this data with data on Soviet institutes responsible for negative ion beam development. The Soviets are developing intense negative ion beams as the basis for creating neutral beams for injection into mirror traps and tokamaks, for inertial confinement fusion, and possibly for exoatmospheric beam weapon applications. The report focuses specifically on surface-plasma-type ion sources, which were first developed in the USSR and which show great promise for creating beams of high intensity, high brightness, and low emittance. Mechanisms for optimum negative ion beam transport are also discussed.
A small, permanent-magnet insert structure for the removal of electrons from pulsed, extracted, negative ion beams has been developed at Lawrence Berkeley National Laboratory. The device was computer modeled and designed for an extraction field strength of 3 kV/mm. The testing was carried out with a rf driven multicusp ion source optimized for the production of H{sup {minus}} ions and pulsed at a few Hz with pulse widths of several hundreds of {mu}s. It is demonstrated that the insert structure together with a collar can remove over 98{percent} of electrons from the extracted H{sup {minus}} ion beam without any significant deterioration of the H{sup {minus}} ion output. Application to other negative ion beams can be expected from this magnetic collar insert. {copyright} {ital 1996 American Institute of Physics.}
The morphological evolution of ripples formed on the surface of Cd2Nb2O7 pyrochlore single crystals by focused ion beam (FIB) bombardment was investigated using in situ electron microscopy. At high ion fluences and off-normal bombardment angles, faceted surface ripples with a terrace-like structure were observed. The ripple propagation direction was oriented along the projected ion beam direction at incident angles ranging from 35 to 65 following high-dose ion bombardment. One side of the terrace was found to be perpendicular to the incident ion beam direction, while the other side was parallel to the ion beam. The terrace propagation velocity and direction were determined and interpreted on the basis of this asymmetric structure. A model based on the propagation of a shock wave that effectively self-selects a stable slope, was developed in order to explain the ...
Linearly polarized laser radiation accelerates electrons to very high velocities and these electron form a sheath layer on the rear side of thin targets where preferentially protons are accelerated. When mass-limited targets are used, the lateral transport of the absorbed laser energy is reduced and the accelerating field is enhanced. For targets consisting of two ion species, heavier ions facilitate formation of quasi-monoenergetic bunch of lighter ions. For circularly polarized light, fast electron production is suppressed by the absence of the oscillatory component of the ponderomotive force. Ions are accelerated on the front side by the separation field and very thin foil can be accelerated as one massive quasi-neutral block. As all ion species acquire the same velocity, this acceleration mechanism is preferred for heavier ions.
There is currently great interest in combining focused ion beam (FIB) and scanning electron microscopy technologies for advanced studies of polymeric materials and biological microstructures, as well as for sophisticated nanoscale fabrication and prototyping. Irradiation of electrically insulating materials with a positive ion beam in high vacuum can lead to the accumulation of charge, causing deflection of the ion beam. The resultant image drift has significant consequences upon the accuracy and quality of FIB milling, imaging and chemical vapour deposition. A method is described for suppressing ion beam drift using a defocused, low-energy primary electron beam, leading to the derivation of a mathematical expression to correlate the ion and electron beam energies and currents with other parameters required for electrically stabilizing these challenging materials.
To suit the needs of development for manufacture VLSI, we started to investigate liquid metal ion sources (LMIS) and focused ion beam (FIB) in 1984. Many kinds of emitters viz. neddle type, co-axial type and capillary type of Ga and Au LMIS and three kinds of eutectic alloys LMIS (Au-Si, Au-Si-Be, Pd-Ni-Si-Be-B) have been tested. A program which can calculate focused ion guns has been written. Four kinds of foused ion guns have been operated, a fine beam with diametic 0.1 #mu#m is obtained. Using the FIB a scanning ion microscope has been constructed. Some tests of etching and self-developing of nitrocellulose are described. (author).
This chapter consists of some points including an introduction, the basic parts of mass spectroscope device, sample introduction into the inductively coupled plasma, pneumatic nebuliser, ultrasonic nebuliser, dry gas cloud system, laser ablation unit, inductively coupled plasma-ion source, extraction of ions from ion source, mass analysis, quad-polar mass spectrometer, dual assembly mass spectrometer, mass spectrometer by calculation of time of flight, ion interferences and the ability of resolution, ion counter, working conditions of inductively coupled plasma mass spectroscope device, efficiency of ion transportation in an inductively coupled plasma mass spectroscope device and applications of analysis using mass spectroscope of induced plasma including nuclear, industrial, geological, environmental and archaeological applications, measurement of isotopes ...
The energy deposited by the passage of a single, energetic, heavy-ion through a semiconductor produces dense electron-hole (eh) pair concentrations near the ion trajectory. The size, shape, and charge density of an ion track represent critical parameters for many models of single event phenomena. The authors describe the design and uses of possible semiconductor test structures for measuring the initial radial distribution of charge and subsequent charge transport in a high energy, heavy-ion track. Numerical simulations show how the test structure can resolve different radial distributions of charge within an ion track. The test structure simulations also show the importance of accurately representing ion track structure in single event effects simulations.
Changes in technology have resulted in new ways for bankers to deliver their services to costumers. Electronic banking systems in various forms are the evidence of such advancement. However, information security threats also evolving along this trend. This paper proposes the application of Analytic Hierarchy Process (AHP) methodology to guide decision makers in banking industries to deal with information security policy. The model is structured according aspects of information security policy in conjunction with information security elements. We found that cultural aspect is valued on the top priority among other security aspects, while confidentiality is considered as the most important factor in terms of information security elements.
This guide accompanies the following article: Gabrielle Poeschl, `What Family Organization Tells Us about Fairness and Power in Marital Relationships', Social and Personality Compass 1/1 (2007): 557-571, 10.1111/j.1751-9004.2007.00026.x Author's Introduction One thing that often strikes me, when I talk with people, is the human capacity to accept and defend surprising aspects of the social life. Thus, we have some feeling that the separation between the domestic and the public spheres has not always existed, but we are ready to assume that in the first human groups, men went out hunting to feed their family, while women stayed in the camp to take care of the children. Even in the face of evidence to the contrary, we are reluctant to question the opinion that men and women differ in persona...
The traffic flow information guidance can improve the operating efficiency of regional traffic. On the basis of the information guidance model and survey data, this paper takes advantage of the VISSIM software to simulate the traffic in a region within the Southwest Second Ring of Beijing constructed by six roads and six intersections and makes a comparative evaluation on the operation of the regional road traffic flow before and after the implementation of the traffic flow information guidance measures. The analysis of five different guided flow cases shows that if the guided left-turn traffic flows in southbound I.A increases from 10% to 30%, the travel time of the left-turn traffic flow in southbound I.A has a reduction from 18% to 42%, and its delay also reduces from 234 s to 164 s. In...
Objective To report the clinical response to image-guided percutaneous cryotherapy (IPC) for the palliative management of localized metastases in patients with gynecologic malignancies. Methods Institutional review board approval and patient consent were obtained. Gynecologic oncology patients were identified from our institution's cryotherapy database from August 2003 to August 2007. Cryotherapy was performed with 2.4?mm diameter probes (Endocare, Irvine, CA) with ultrasound or computerized tomography (CT) guidance under conscious sedation and local anesthesia. Follow-up was conducted by imaging studies and clinical encounters, using Response Evaluation Criteria in Solid Tumors (RECIST criteria). Results Twenty-eight ablation sessions were performed for 41 metastatic foci in 15 patients w...
This Safety Analysis Report (SAR) is prepared in compliance with the requirements of DOE Order 5480.23, Nuclear Safety Analysis Reports, and has been written to the format and content guide of DOE-STD-3009-94 Preparation Guide for U. S. Department of Energy Nonreactor Nuclear Safety Analysis Reports. The Hot Cell Facility is a Hazard Category 2 nonreactor nuclear facility, and is operated by Sandia National Laboratories for the Department of Energy. This SAR provides a description of the HCF and its operations, an assessment of the hazards and potential accidents which may occur in the facility. The potential consequences and likelihood of these accidents are analyzed and described. Using the process and criteria described in DOE-STD-3009-94, safety-related structures, systems and components are identified, and the important safety functions of each SSC are described. Additionally, information which describes the safety management programs at ...
The Department of Energy (DOE) and its predecessors have conducted research and development (R&D) in geothermal energy since 1971. To develop the technology needed to harness the Nation's vast geothermal resources, DOE's Office of Geothermal and Wind Technologies oversees a network of national laboratories, industrial contractors, universities, and their subcontractors. The following mission and goal statements guide the overall activities of the Office of Geothermal and Wind Technologies. This Federal Geothermal Program Research Update reviews the specific objectives, status, and accomplishments of DOE's Geothermal Program for Federal Fiscal Year (FY) 1999. The information contained in this Research Update illustrates how the mission and goals of the Office of Geothermal and Wind Technologies are reflected in each R&D activity. The Geothermal Program, from its guiding principles to the most detailed ...
Manufacturers may be required to design transformers to overload specifications. Oil viscosity changes and loss variation with temperature are not accounted for in the industry loading guide. A comprehensive test program was performed using a winding assembly with imbedded thermocouples. Steady state and transient tests were performed for natural and non-directed forced oil circulation. The temperature distribution in the winding was not linear with height as usually assumed. A large number of temperature sensors is required to determine the hot spot location. The location of the hot spot was found to be different and less predictable for natural oil circulation compared with non-directed forced oil circulation especially during overload conditions. This paper reports that improved loading guide equations were developed to account for oil viscosity, resistance change, cooling duct oil rise, and location of the hot spot.
The Advanced Neutron Source will be a new world-class facility for research using hot, thermal, cold, and ultra-cold neutrons. The heart of the facility will be a 330-MW (fission), heavy-water cooled and heavy-water moderated reactor. The reactor will be housed in a central reactor building, with supporting equipment located in an adjoining reactor support building. An array of cold neutron guides will fan out into a large guide hall, housing about 30 neutron research stations. Appropriate office, laboratory, and shop facilities will be included to provide a complete facility for users. The ANS is scheduled to begin operation at the Oak Ridge National Laboratory early in the next decade. This PDR document defines the plant-level requirements for the design, construction, and operation of ANS. It also defines and provides input to the individual System Design Description (SDD) documents. Together, this PDR document and the set of SDD documents ...
The present invention concerns a negative ion source electrode which can be preferably used in a neutral particle injection device using negative ions for a thermonuclear reactor. Negative ion beams are deflected to the direction opposite to the deflecting direction by magnetic fields by using an electron suppression electrode having electrode holes with the position previously displaced before negative ion beams are accelerated to have a high energy by an accelerator thereby correcting the orbit of the negative ion beams easily. In addition, since the deflection correction electrode having the electrode holes is disposed, a proper voltage is applied to the deflection correction electrode to correct the orbit of the negative ion beams conveniently. Since the deflection correction electrode has a simple structure of a thin flat plate having electrode holes, the ...
Liquid metal ion sources (LMISs) with Ga as ion species are widely used in focused ion beam (FIB) technology for micromachining and surface treatment on the sub-micron and nano-scale. Key features of a LMIS for investigating mechanical properties and 3D-microfabrication of materials are long life-time, high brightness, stable ion current and a highly effective milling ability for the material to be modified. In order to increase the material removal rate, heavier ions than Ga and their clusters should be applied. Bismuth (Bi) is the heaviest, non-radio-active element in the periodic table, is non-toxic and exhibits a low melting point. We have thus produced a long-life (about 1000 h) Bi LMIS with a good beam performance, applicable in any FIB system. Since Bi is the only element in this source, it is not necessary to separate it from other ions by a mass filter. ...
A method of patterning n-type GaAs, InP, InGaAs, and InGaAsP by photoelectrochemical (PEC) etching in conjunction with a submicron focused ion beam (FIB) at low dose is described. The ion beam is used to produce damage in a desired pattern in the material. Subsequent PEC etching of the material reveals the ion induced features in relief. The procedure is highly sensitive, requiring a dose of only 5 x 10/sup 9/ ions/cm/sup 2/ for the differential etch to become apparent. The sensitivity allows rapid pattern generation in our FIB system.
Laser optical pumping can be used to produce polarized alkali atom beams or polarized alkali vapor targets. Polarized alkali atom beams can be converted into polarized alkali ion beams, and polarized alkali vapor targets can be used to produce polarized H/sup -/ or /sup 3/He/sup -/ ion beams. In this paper the authors discuss how the polarized alkali atom beams and polarized alkali vapor targets are used to produce polarized ion beams with emphasis on the production of polarized negative ion beams.
This document reports the results of testing of spent ion exchange media pretreatment technologies. Emphasis of the testing activities has been on screening pretreatment technologies, such as drying and emulsification, which are compatible with vitrification, cementation, and incineration. Ion exchange media tested for cementation and incineration pretreatment technologies were typical organic ion exchange resins and inorganic zeolites. The ion exchange medium tested for vitrification pretreatment technologies was inorganic zeolite. The results of testing activities are discussed in detail in this report.
We report experimental evidence of a previously unseen species-dependent effect in the transverse emittances of momentum analysed /sup 28/Si/sup -/, /sup 58/Ni/sup -/ and /sup 197/Au/sup -/ ion beams generated by caesium ion sputtering. The high-resolution emittance measurement techniques employed in this work have enabled us to estimate the energy spreads of these ion beams; differences in the widths of the energy distributions are the origin of the observed differences in emittances of the ion beams investigated. (author).
This paper describes the design of a high-voltage negative ion source based on a magnetically insulated diode and generating microsecond pulses. Plane an cylindrical cathodes have been tested. The spatial and angular distributions of negative ions in the beam have been measured. The content of negative ions with different masses in the beam are given. The ion current density measured by a Faraday cup was up to 1 A/cm{sup 2} for the radial beam and 30-40 A/cm{sup 2}.
Solenoid transport of high current, heavy ion beams is considered for several stages of a heavy ion fusion driver. In general this option is more efficient than magnetic quadrupole transport at sufficiently low kinetic energy and/or large e/m, and for this reason it has been employed in electron induction linacs. Ideally an ion beam would be transported in a state of Brillouin flow, i.e. cold in the transverse plane and spinning at one half the cyclotron frequency. The design of appropriate solenoids and the equilibrium and stability of transported ion beams are discussed. An outline of application to a fusion driver is also presented.
Gallium liquid-metal ion sources that have been introduced in the late 1970s have allowed the development of a new class of micro- and nanofabrication tools collectively denominated as focused ion beam (FIB) machines. To investigate the potential of a helium beam in such a FIB instrument the authors have tested a room-temperature electron beam ion trap coupled with a high resolution FIB machine. In this letter they present their first results in target imaging using a helium beam with a resolution that allows to account for a beam diameter in the submicrometer range.
The results of an investigation on the production of Group IIA atomic and molecular negative ion beams formed in a cesium-sputter negative ion source are presented. The sputtering material was formed by pressing pellets of stoichiometric mixtures of the Group IIA element carbonates and 10% copper powder. Negative ions of several alkaline-earth elements and their oxides have been observed. Beam intensities as high as 180 pA have been observed for Sr{sup -}and 20 nA for SrO{sup -}. (orig.).
The results of an investigation on the production of Group IIA atomic and molecular negative ion beams formed in a cesium-sputter negative ion source are presented. The sputtering material was formed by pressing pellets of stoichiometric mixtures of the Group IIA element carbonates and 10% copper powder. Negative ions of several alkaline-earth elements and their oxides have been observed. Beam intensities as high as 180 pA have been observed for Sr"-and 20 nA for SrO"-. (orig.).
The bibliography contains citations concerning plasma immersion ion implantation (PIII) and equipment. PIII is a new technique to implant plasma ions into materials for surface modification and treatment. Topics include plasma nitriding, semiconductor doping, ion energy distribution, ion dose, pulsed plasma, metal plasma, and defect passivation. References also review applications in semiconductor device and integrated circuit manufacture, silicon material fabrication, aerospace bearings, carbon coatings on metals, and ceramic coatings. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)
Trapped ions are a near ideal system to study quantum information processing due to the high degree of control over the ion's external confinement and internal degrees of freedom. We demonstrate the key steps necessary for trapped ion quantum computing and focus on phonon-mediated entangling gates. We highlight several key algorithms implemented over the last decade with these gates and give a detailed description of Grover's quantum database search implemented with two trapped ion qubits.
A new coumarin-based sensor molecule (L1) has been synthesized and this was found to bind calcium and magnesium ions more effectively as compared to other alkali/alkaline earth/lanthanide and certain transition metal ions. A significant enhancement in fluorescence intensity was observed on binding to Ca2+ and Mg2+ ions; while a minor quenching was observed for weakly bound Hg2+, Ni2+, Fe3+, and Co2+ ions. PET process, coupled with the ICT process, is proposed to explain the observed spectral response.
The variations of measurements were estimated for microamounts SO_4"2"-, Br"-, I"- ions in samples of carnallite by ionchromatography method. The composition of carbonate eluent was verified. The investigated minima were about 0,004 %, 0,001 %, 0,01 % for SO_4"2"-, Br"-, I"- completively correspondingly. It was shown that the limit of ion-chromatography measurement would be decreased when Br"- and I"- ions were concentrated by extraction before. Besides the determination of I"- ion in carnallite was preformed by potentiometry with I"--ionselective electrode. 6 refs.; 3 tabs.
The interest of irradiation by carbon ions is in the fact that the carbon ions leave all their energy to a determined depth. ( phenomenon known under the name of Bragg peak)This high diffusion in tissue gives an RBE particularly high. The indications of this therapy are chordomas, and chondrosarcomas of the skull base, some cyst adenoid carcinomas, pulmonary cancer, sarcomas, hepato carcinomas, melanomas. In the light of results in term of efficiency, the place of irradiation by carbon ions should widen. (N.C.)
Average emittance data for ion beams extracted from cesium-sputter negative ion sources equipped with spherical, ellipsoidal, and cylindrical geometry cesium-surface ionizers are presented. The attributes of the respective source geometries are described in terms of their cesium ion optical properties. The results of recent measurement of the emittances of momentum-analyzed beams extracted from the ellipsoidal geometry source are also presented. These measurements indicate the presence of a species-dependent effect. The effect is believed to be attributable to differences in the energy spreads of the respective negative ion beams introduced by the sputter generation process.
Average emittance data for ion beams extracted from cesium-sputter negative ion sources equipped with spherical, ellipsoidal, and cylindrical geometry cesium-surface ionizers are presented. The attributes of the respective source geometries are described in terms of their cesium ion optical properties. The results of recent measurement of the emittances of momentum-analyzed beams extracted from the ellipsoidal geometry source are also presented. These measurements indicate the presence of a species-dependent effect. The effect is believed to be attributable to differences in the energy spreads of the respective negative ion beams introduced by the sputter generation process. 11 refs., 8 figs.
The validity is given to the newly proposed two {delta}f method for neoclassical transport calculation, which can be solve the drift kinetic equation considering effects of steep plasma gradients, large radial electric field, finite banana width, and an orbit topology near the axis. The new method is applied to the study of ion transport with steep plasma gradients. It is found that the ion thermal diffusivity decreases as the scale length of density gradient decreases, while the ion particle flux due to ion-ion self collisions increases with increasing gradient. (author)
Ion Beam Induced Luminescence (IBIL) and Ion Beam Induced Charge Collection (IBICC) have been applied in the study of the luminescence emission efficiency and investigation of the homogeneity of the luminescence emission in phosphors. The IBIL imaging was performed by using sharply focused ion beams or broad/partially-focused ion beams. The luminescence emission homogeneity in samples was examined to reveal possible distributed crystal-defects that may lead to the inhomogeneity of the luminescence emission in samples.The purpose of the study is to search for suitable luminescent thin films that have high homogeneity of luminescence emission, large IBIL efficiency under heavy ion excitation, and can be placed as a thin layer on the top of microelectronic devices to be analyzed with Ion Photon Emission Microscopy (IPEM). The emission yield was found to be low for ...
Production of intense negative ion beams in magnetically insulated diodes was studied in order to develop an understanding of this process by measuring the ion-beam parameters as a function of diode and cathode plasma conditions in different magnetically insulated diodes. A coral diode, a racetrack diode, and an annular diode were used. The UCI APEX pulse line, with a nominal output of 1MV, 140kA, was used under matched conditions with a pulse length of 50 nsec. Negative-ion intensity and divergence were measured with Faraday cups and CR-39 track detectors. Cathode plasma was produced by passive dielectric cathodes and later, by an independent plasma gun. Negative-ion currents had an intensity of a few A/cm{sup 2} with a divergence ranging between a few tenths milliradians for an active TiH{sub 2} plasma gun and 300 milliradians for a passive polyethelene cathode. Negative ions were ...
Electron cyclotron resonance (ECR) ion sources possess several advantages over ion sources conventionally used for injectors of electrostatic accelerators: improved reliability, high efficiency, simplicity, and the capability of generating bright, high-current ion beams. We have adapted a high-current ECR source originally developed as an injector for a CW RFQ proton linac to serve as a source of intense negative-ion beams for the Tandem Accelerator Superconducting Cyclotron (TASCC) facility at Chalk River. The range of ion species of the source has been extended from H{sup 1+} alone up to Bi{sup 1+}, with both gaseous and nonvolatile feeds. Two intense negative-ion beams of He{sup -} and O{sup -} have been generated so far with the source coupled to a standard charge-exchange canal. We foresee no major problems generating a broad range of negative ...
Electron cyclotron resonance (ECR) ion sources possess several advantages over ion sources conventionally used for injectors of electrostatic accelerators: improved reliability, high efficiency, simplicity, and the capability of generating bright, high-current ion beams. We have adapted a high-current ECR source originally developed as an injector for a CW RFQ proton linac to serve as a source of intense negative-ion beams for the Tandem Accelerator Superconducting Cyclotron (TASCC) facility at Chalk River. The range of ion species of the source has been extended from H1+ alone up to Bi1+, with both gaseous and nonvolatile feeds. Two intense negative-ion beams of He- and O- have been generated so far with the source coupled to a standard charge-exchange canal. We foresee no major problems generating a broad range of negative ions with this ...
The effect of Al and Be ions pre-implantation on microstructural change and, the formation and growth of He bubbles in SiC/SiC composite was investigated. Four kinds of ion implanted specimens were prepared with 100 appm Al, 1000 appm Al, 100 appm Be and 1000 appm Be implanted. No microstructural change was observed in the matrices and fibers of SiC/SiC composites implanted with Al or Be ions up to 1000 appm. The un-implanted and Al or Be pre-implanted SiC/SiC composites were simultaneously irradiated to 10 dpa using triple ion-beams (6.0-MeV Si{sup 2+}, 1.0-MeV He{sup +} and 340-keV H{sup +}) at 1000 deg. C. Helium bubbles were formed in every matrix and fiber irradiated by triple ion-beams. The size of He bubbles in the matrix was increased by implanting Al or Be ions and increased with increasing amount of implanted Al or Be ions. The ...
The effect of Al and Be ions pre-implantation on microstructural change and, the formation and growth of He bubbles in SiC/SiC composite was investigated. Four kinds of ion implanted specimens were prepared with 100 appm Al, 1000 appm Al, 100 appm Be and 1000 appm Be implanted. No microstructural change was observed in the matrices and fibers of SiC/SiC composites implanted with Al or Be ions up to 1000 appm. The un-implanted and Al or Be pre-implanted SiC/SiC composites were simultaneously irradiated to 10 dpa using triple ion-beams (6.0-MeV Si"2"+, 1.0-MeV He"+ and 340-keV H"+) at 1000 deg. C. Helium bubbles were formed in every matrix and fiber irradiated by triple ion-beams. The size of He bubbles in the matrix was increased by implanting Al or Be ions and increased with increasing amount of implanted Al or Be ions. The size of He ...
This thesis presents the study of the slowing down process of fast heavy ions inside matter. In the framework of this research, the influence of the target density on the stopping process is investigated. Experiments on the interaction of {sup 48}Ca{sup 6+}-{sup 48}Ca{sup 10+} and {sup 26}Mg{sup 5+} ion beams with initial energies of 11.4 MeV/u and 5.9 MeV/u with solid and gaseous targets have been carried out. A novel diagnostic method, X-ray spectroscopy of K-shell projectile radiation, is used to determine the ion charge state in relation to its velocity during the penetration of fast heavy ions inside the stopping material. A spatially resolved analysis of the projectile and target radiation in solids is achieved for the first time. The application of low-density silica aerogels as stopping media provided a stretching of the ion stopping length by 20 - 100 times in comparison ...
Negative ions have attractive features as drivers for inertial confinement fusion, because they will avoid electron cloud effects, and could be efficiently photodetached to neutrals after the final focus, which could also be beneficial in heating warm dense matter targets. The halogens have large electron affinities, and thus should be able to produce high current densities of relatively robust negative ions. Recent experiments comparing chlorine beams to argon beams using the same source, extraction optics, and diagnostics have demonstrated that Cl"- beams can be produced with similar emittance to Ar"+ beams, and with about 34 the current density from the same configuration. The observed effective beam temperature of about 13eV, and the similarity of current densities show that negative halogen beams can meet the current density and emittance requirements of heavy ion fusion. The near equivalence of the Cl"- and ...
Donnan dialysis with ion-exchange membranes was studied under various kinds of experimental conditions using ions of different valences. The diffusion coefficients (D{sub d}) of various kinds of ions in the ion-exchange membrane were obtained by curve fitting an equation derived from the mass balance to three kinds of Donnan dialytic experiments. It was found that the value of D{sub d}/D{sub s} using D{sub d} of monovalent ions in Donnan dialysis with a set of monovalent feed ions and bivalent driving ions was 1/175, where D{sub s} represents a diffusion coefficient in solution. D{sub s} was calculated from the Nernst-Einstein equation substituted by the ionic conductance of ions at infinite dilution in water. Using D{sub d} of bivalent ions in Donnan dialysis with the same set led to a D{sub ...
Each WG has two Co-Chairs and six Vice-Chairs, except WG III, which for the Fifth ...Assessment cycle has three Co-Chairs.The Co-Chairs guide the WGs in fulfilling their ...IN THIS ISSUE A Brief History of the IPCC 1 IPCC-31 Report 3 Approval of the Draft Report of
This report contains preconceptual designs and planning level life-cycle cost estimates for managing hazardous waste. The report`s information on treatment, storage, and disposal modules can be integrated to develop total life-cycle costs for various waste management options. A procedure to guide the US Department of Energy and its contractor personnel in the use of cost estimation data is also summarized in this report.
This site focuses on the subject of volcanoes, including how volcanoes form, the destruction they can cause, effects of volcanoes on the environment, where active volcanoes are found, volcanoes of other planets, and the different volcano types. Designed as an electronic tour, it guides the user through different web sites and outlines teaching objectives, concepts covered, and new vocabulary. There is a teacher resources section with links for more information, and questions for students to answer along the way.
Ventricular septal defect after acute myocardial infarction (AMI) is a complication associated with poor outcome in the absence of intervention. We report a case of successful TEE guided transcatheter closure of a post myocardial infarction (MI) ventricular septal defect (VSD) with an Amplatzer occluder in a 79 years old male with cardiogenic shock.
The concept of unstable burst fracture has been discussed since over 50 years and this injury has received much attention in the literature as regards its radiological diagnosis and clinical treatment. The purpose of this article is to review the way we use imaging to diagnose the injury and to guide treatment.
The necessity of the electron beam machine characterization via dose measurement is discussed. It includes a measurement of comprehensive dose distribution (at known X and Z axis) for verification of the machine performance. The acquired data were then used to develop the irradiation parameters such as energy, current, distance, conveyor speed, exposure rate and depth inside product to be irradiated. These parameters will be used as a guide for the routine irradiations. (Author)
Those who teach college students have extensive training in their disciplines, but unlike their counterparts at the high school or elementary school level, they often have surprisingly little instruction in the craft of teaching itself. "The Chicago Handbook for Teachers, Second Edition", is an extraordinarily helpful guide for anyone facing the daunting challenge of putting together a course and delivering it successfully. Representing teachers at all stages of their careers, the authors, including distinguished historian Alan Brinkley, offer practical advice for almost any situation a new teacher might face, from preparing a syllabus to managing classroom dynamics. Beginning with a nuts and bolts plan for designing a course, the handbook also explains how to lead a discussion, evaluate your own teaching, give an effective lecture, supervise students' writing and research, create and grade exams, and more. This new edition is thoroughly revised for contemporary ...
In spite of the fact that market requirements for new plants continue to be restricted, steam turbine technology and operation engineers have left nothing undone to improve products and operating characteristics. They are generally guided by the principle of optimum economic power supplies but lowest pollution. The new eastern markets are expected to give new impulses to steam turbine design. Cogeneration is of special future importance. (orig.).
This chapter is concerned with standards and guidances for limiting radiation exposures. It is divided into three sections, each of which has several parts. Section 1: Ionizing Radiation -- Standards and Guidances Applicable to the Public: Part A, Radiation Protection Standards; Part B, Environmental Radiation Standards; Part C, Exempt Levels of Radioactivity; Part D, Protective Action Guides for Accidents. Section 2: Ionizing Radiation -- Standards Applicable to the Workplace. Section 3: Medical and Other Standards.
The rod drop time event of the Daya Bay Nuclear Power Plant is caused by the malfunction of the guide tube developed by Framatome. Three temporary solutions were implemented successively and the long term solution was found in the process of searching for the root cause. The different solutions and the root cause are introduced. The safety analysis and license of the solutions are mainly discussed. Experiences and lessons are drawn by summarizing the important items related to nuclear safety.
This quality assurance plan (QAP) is designed ensure that the methodologies and the data used for environmental cleanup and treatment studies at the Nevada Test Site are both usable and defensible. The QAP serves two purposes in this regard: (1) to guide the preparation of procedures for carrying out the tasks of the Basic Environmental compliance and Monitoring program (BECAMP); and (2) to help management track the progress of those tasks.
This comprehensive guide offers several tried and true steps to help you successfully manage the complex process of developing free software. Topics include project management, developer motivation, technical infrastructure to support collaboration, and project promotion. Producing Open Source Software is ideal for developers starting their own free software projects, or people who simply want to participate in the process.
The book is a German translation of an American textbook with the original title ''MRI Survival Guide'' and is intended to serve as an introductory guide for beginners or a reference book for quick information. Readers will find information on the fundamentals of the technology and methodology of MRI as well as all details of relevance to practice in a precise and easy-to-grasp arrangement, covering all anatomic areas of interest, illustrations and descriptions of characteristic signs of pathologic processes, high-quality and unusually large-sized diagnostic pictures, a modern didactic concept for quick orientiation, including surveys, tables, and reproductions for visualisation of contents. (orig./CB) [German] Praktisch jeder Mediziner wird im Laufe seiner Berufstaetigkeit mit der MRT konfrontiert - unabhaengig davon ob in der Radiologie, Orthopaedie, Gynaekologie, Chirurgie, Neurologie oder sonstigen ...
We use the method of Padg approximants and Fourier transform techniques to treat analytically the problem of transverse and longitudinal mode evolution in FELs. We obtain simple relations providing a transparent understanding of the dynamic of pulse propagation effects and of transverse mode guiding. We discuss the interplay with inhomogeneous broadening effects and derive gain formulae including longitudinal and transverse mode couplings.
ObjectiveWe wanted to assess the usefulness of four-dimensional (4D) ultrasonography (US), i.e., real-time three-dimensional US, as an adjunct for performing various US-guided interventional...Full Text Available
This document draws together data on hydroelectric power generation and dam construction for 1996. Machinery such as turbines and hydroelectric generators are listed together with their manufacturers. Contact addresses for international organizations concerned with water power are listed. Listings are also given for hydro resources worldwide, and the global distribution of pumped-storage plants, dams and hydroelectric plants. Company data is also listed providing a buyer`s guide for 1996. (UK)
These documents defines the interconnection France-England rules for the 2000 MW DC submarine cable directly linking the transmission networks of England and Wales and France. Rights to use Interconnector capacity from 1 April 2001 are to be offered through competitive tenders and auctions, full details of which are set out in the Rules. The contract and a guide to the application form are provided. (A.L.B.)
A 10.6-micron wavelength free-electron laser (FEL) amplifier has been operated using a 45-MeV, 600-A electron beam from the Advanced Test Accelerator (ATA) and a 15.36-meter long electromagnetic wiggler. The peak small signal power gain was 27 dB(500). Gain guiding was observed to confine the amplified laser beam.
This manual is a guide to the services provided by the Hanford Internal Dosimetry Program (IDP), which is operated by the Pacific Northwest National Laboratory.( ) for the U.S. Department of Energy Richland Operations Office, Office of River Protection and their Hanford Site contractors. The manual describes the roles of and relationships between the IDP and the radiation protection programs of the Hanford Site contractors. Recommendations and guidance are also provided for consideration in implementing bioassay monitoring and internal dosimetry elements of radiation protection programs.
This 2001 edition of the guide to UK renewable energy companies examines the geothermal heat pump sector, and discusses the technology involved, installations of geothermal heat pumps, the activity in the UK market with increased interest in UK geothermal heat pump products from abroad, and developments in the building sector. The UK government's increased support for the industry including its sponsorship of the Affordable Warmth programme, and the future potential of ground source systems are discussed.
This 2001 edition of the guide to UK renewable energy companies examines the geothermal heat pump sector, and discusses the technology involved, installations of geothermal heat pumps, the activity in the UK market with increased interest in UK geothermal heat pump products from abroad, and developments in the building sector. The UK government's increased support for the industry including its sponsorship of the Affordable Warmth programme, and the future potential of ground source systems are discussed.
For most of the history of binary star astronomy, systems have been classified largely on the basis of how they were discovered and qualitative appearance of their spectra and light curves. Present understanding of single and double star evolution has now progressed to the point where most of the classes previously identified, and some new ones, can be arranged into evolutionary sequences, depending primarily on the initial masses and separation of the component stars.
This report describes the 2005 version of the Fluka particle transport code. The first part introduces the basic notions, describes the modular structure of the system, and contains an installation and beginner's guide. The second part complements this initial information with details about the various components of Fluka and how to use them. It concludes with a detailed history and bibliography.
Contains Executive Summary and Chapters on: Energy and the Internet; Internet Developments; Search Guide; Oil and Gas Industry; Electricity and Utilities; Nuclear Energy; Coal Industry; Alternative Energy; Government and Supranational Agencies; Research Institutions and Universities; Energy Statistics; Commodity Pricing and financial Markets; Company Information; Country Information; Associations; Engineering; Environment; Patents, Trademarks and Standards; News; Industry Events; Miscellaneous. (Author)
A simplified stormwater management model has been developed to provide an inexpensive, flexible tool for planning and preliminary sizing of stormwater facilities. The model was developed to be part of a methodology for use in the management of stormwater that utilizes both simple...
The device is made by a tool at the end of a flexible cable, a motor for the rotation of the flexible, a linear drive with a guide for it between the winder and the tube.
This is a patent for a device to increase compaction of the loaded batch in a coking chamber that assures a balanced compaction of the batch from the upper to the bottom layer. The leveling rod has a device on the external end that causes the rod to shift vertically and bring pressure on the material and the pressing attachment. Opposite the loading hoppers of the coking chambers there are guides that ensure the rod will be sunk perpendicularly into the loaded material.
As a self-teaching tool, this illustrated guide facilitates home study of the complexities of thoracic CT's. Over 400 illustrations and accompanying copy are used to provide a basis for understanding the CT appearances of disease processes and a comparison of CT lookalikes. It updates new and interesting developments in the format of case presentations.
A heuristic algorithm that employs fuzzy logic is proposed to the power system transmission expansion planning problem. The algorithm is based on the divide to conquer strategy, which is controlled by the fuzzy system. The algorithm provides high quality solutions with the use of fuzzy decision making, which is based on nondeterministic criteria to guide the search. The fuzzy system provides a self-adjusting mechanism that eliminates the manual adjustment of parameters to each system being solved. (author)
In this paper, the adaptive optics (AO) system at Keck Observatory is characterized. The AO system is described in detail. The physical parameters of the lenslets, CCD and deformable mirror, the calibration procedures and the signal processing algorithms are explained. Results of sky performance tests are presented: the AO system is shown to deliver images with an average Strehl ratio of up to 0.37 at 1.59 {micro}m using a bright guide star. An error budget that is consistent with the observed image quality is presented.
We derive the expression for spontaneous emission rate in finite one-dimensional photonic crystal with arbitrary defects using the effective resonator model to describe electromagnetic field distributions in the structure. We obtain explicit formulas for contributions of different types of modes, i.e. radiation, substrate and guided modes. Formal calculations are illustrated with a few numerical examples, which demonstrate that the application of effective resonator model simplifies interpretation of results.
EPA's Brownfields Economic Redevelopment Initiative was established to assist states, site planners and other community stakeholders to work together to assess, cleanup and sustainably reuse brownfields sites. EPA has developed a series of guides to help these parties effectively...
Literature references related to definition, generation, and use of evaluated cross section uncertainty (variance-covariance) files are listed with comments intended primarily to guide the reader toward materials of immediate interest. Papers are also cited that cover covariance information for individual experiments and that relate to production and use of multigroup covariance matrices. Titles are divided among several major categories.
Fermi radii and velocities are determined by deconvoluting de Haas-van Alphen data. Comparison of these data with accurate augmented-plane-wave band-structure results establishes the reliability of the augmented-plane-wave calculations and allows a determination of the anisotropic many-body enhancement factor lambda(k). The Fermi-surface average of 1.33 suggests a large electron-electron contribution. Our anisotropic lambda(k) porvides a detailed test and guide for model calculations of many-body enhancement.
Our goal is to determine an optimized image-guided setup by comparing setup errors determined by two-dimensional (2D) and three-dimensional (3D) image guidance for head and neck cancer (HNC)...Full Text Available
... Further information For more detailed information on available accommodation, refer to our housing guide At home with us, visit Residential Services, or contact : T +44 (0)1273 678220 E housing@sussex.ac.uk Davidrsquo;s perspective lsquo;When my wife and I decided to study at Sussex, we applied for University accommodation. We were delighted with the lovely self-contained flat on Clifton Road in Brighton that we got via the Housing Office. ...
The purpose is to provide a source of information that can be used to assist personnel in the planning, training, and execution of radiological work using the principles of ALARA. This document is not intended to replace HNF or WHC Control Manual requirements. The ALARA Tools-List provides detailed information on the use and procurement of engineered controls, mockup training guidelines, and good radiological work practices that have been proven to be ALARA.
...authority's and schools' prospectuses Finding a school to suit your child School performance: test results and Ofsted reports Applying for a school place Once you ... Finding a school to suit your child School performance: test results and Ofsted reports Applying for a school place: admissions criteria Apply for ...
...DEPARTMENT OF THE ARMY MILITARY RESERVATIONS AND...REGULATIONS AFFECTING MILITARY RESERVATIONS ...or guide service, dog training for reimbursement...non-profit organizations working in the public...profit, including dog training for reimbursement...non-profit organizations working in the public...
nl/guid /item item titleNieuwe rol overheid nodig voor schone economie/title ...nl/nieuws/nieuwsberichten/2011/nieuwe-rol-overheid-nodig-voor-schone-economie/link description<p>De in de maatschappij ...gt; <a href="/nieuws/persberichten/2011/nieuwe-rol-overheid-nodig-voor-schone-economie">Nieuwe rol overheid nodig voor schone
The possibilities of using both selective heavy ion induced X-ray emission and secondary ion mass spectroscopy (SIMS), for the identification of impurities present at low concentrations in cadmium telluride are examined. The relative concentrations of the impurities along CdTe crystals have been determined by exciting the X-ray emission of the elements in several slices with Ar and Kr ions and by comparing the relative characteristic X-ray emission yields. As a consequence of the quasimolecular inner shell ionization mechanism in heavy ion-atom collisions, Ar and Kr ions allow a strong excitation of the main impurities seen by SIMS namely Si, Cl and Ge, As, with only a minor contribution of Cd and Te. From the changes of the concentrations of the various impurities along the crystal, informations about segregation coefficients and compensation can be obtained.
The LPCTrap setup is a transparent Paul trap dedicated to the measurement of the ??? correlation coefficient a ?? in the ? decay of trapped radioactive nuclides. In a first experiment, the system has been used to record ?105 coincidences between the ? particles and recoiling ions emitted from the decay of 6He?+? ions. The analysis of the collected data has already shown that the size of the 6He?+? ion cloud confined in the Paul trap is a critical parameter, potentially limiting the accuracy on the a ?? measurement. We report here the precise determination of the trapped ion cloud temperature and size. This was performed by extracting the trapped ions toward a position sensitive micro channel plate detector at different phases of the RF driving field. We find a temperature T exp ?= 0.107(7)...
Ion beams of halogens can be produced either positively or negatively charged, depending on the employed ion source. At CERN-ISOLDE, although positively charged fluorine and astatine can be obtained from a hot plasma ion source, they are often contaminated by isobars and molecular sidebands. This has generated a request from the scientific community for fluorine and astatine negative ion beams free of contaminants. The high selectivity ensured by the surface ionisation process also makes negative beams of chlorine, bromine and iodine highly attractive. However, the efficiency figures for negative surface ionisation of fluorine and astatine were lower than the ones from the hot plasma. Here we report our R and D on new surface ion sources suitable for the production of negative halogen beams.
A 500 keV negative-ion based NBI system is under construction for NB current drive and plasma core heating in high density plasma in JT-60U. Part of the beamline and the high voltage power supply required for a verification test of an ion source was completed in March 1995. After having done a high potential test of the power supply, the negative-ion generation and acceleration tests started in June 1995 aiming at deuterium beams of 500 keV, 22A. In initial experiment, deuterium negative-ion beams of 410 keV, 6.1A (2.5 MW) for 0.2 sec, so far, have been achieved. This is the world highest D{sup {minus}} current and negative ion beam power. The construction of the total system will be completed by the beginning of 1996, and the beam injection will start in March 1996.
The in-depth distribution of phases in c-BN films deposited by Ion Beam Assisted Deposition (IBAD) at two different ion energy values (300 and 600 eV) was investigated using the quantitative IR transmission measurements and the HREM technique. Whatever the value of the studied ion energies, the characteristic layered morphology of c-BN film is observed including the interfacial sp"2 zone between the substrate and the c-BN volume. In the case of 600 eV ion energy, this interfacial zone is less well-defined in comparison with 300 eV ion energy and the corresponding thickness is more important. Furthermore, the h-BN phase is more diluted within the c-BN film volume showing that the purest phase concentration of c-BN is found for the lowest ion energy, i.e., 300 eV.
By using megaelectronvolt /sup 4/He ion backscattering techniques and transmission electron microscopy, the authors have investigated the interactions of ion beams with thin film structures in a number of silicide-forming systems. The mixed layer was found to be an equilibrium compound for near-noble metals and an amorphous phase for refractory metals. Differences in behavior have also been observed in near-noble metal systems. For palladium, the Pd/sub 2/Si phase grew with ion dose and remained crystalline up to high dose. For nickel, the compound Ni/sub 2/Si was formed initially and became amorphous on prolonged irradiation. All the results indicate the significance of atomic mobility at target temperatures in determining the phase formation and in explaining the sensitivity of the silicides to ion bombardment.
The present study is devoted to the investigation of the mechanism of aluminium nitriding by a technique that employs implantation of low-energy nitrogen ions and diffusional transport of atoms. The nitriding of aluminium is investigated, because this is a method for surface modification of aluminium and has a potential for application in a broad spectrum of fields such as automobile, marine, aviation, space technologies, etc. However, at present nitriding of aluminium does not find any large scale industrial application, due to problems in the formation of stoichiometric aluminium nitride layers with a sufficient thickness and good quality. For the purposes of this study, ion nitriding is chosen, as an ion beam method with the advantage of good and independent control over the process parameters, which thus can be related uniquely to the physical properties of the resulting layers. Moreover, ion ...
A new technique for ion implantation into concave surface of insulating materials is proposed and experimentally studied. The principle is roughly described by referring to modifying inner surface of a PET (polyethylene terephthalate) bottle. An electrode that is supplied with positive high-voltage pulses is inserted into the bottle. Both plasma formation and ion implantation are simultaneously realized by the same high-voltage pulses. Ion sheath with a certain thickness that depends on plasma parameters is formed just on the inner surface of the bottle. Since the plasma potential is very close to that of the electrode, ions from the plasma are accelerated in the sheath and implanted perpendicularly into the bottle's inner surface. Laser Raman spectroscopy shows that the inner surface of an ion-implanted PET bottle is modified into DLC (diamond-like carbon). Gas permeation ...
Fractionation of isotopes of the alkali metals and the alkaline earth metals in ion exchange chromatography of their chlorides was studied. The heavier isotopes of potassium and rubidium were found to be preferentially fractionated into the ion exchanger phase while the lighter isotopes of lithium, magnesium, calcium and strontium were enriched in the exchanger phase. This can be interpreted as a resultant of the relative significance of isotope effect upon dehydration and isotope effect accompanying the phase change of the hydrated metal ion. Found was no evidence of anomalous isotope effect attributable to the odd-even difference in mass number of isotopes. Based on the spectroscopic and solution chemical data (experimental and theoretical), the isotopic reduced partition function ratios of the hydrated alkaline metal ions and stretching force constants of metal ion-hydrating ...
We report experimental evidence of a previously unseen species-dependent effect in the transverse emittances of momentum-analyzed {sup 28}Si{sup {minus}}, {sup 58}Ni{sup {minus}}, and {sup 197}Au{sup {minus}} negative-ion beams generated by cesium-ion sputtering. The differences in the emittances are found to be principally correlated with differences in the energy spreads in the respective ion beams, which have their origins in the sputter-ejection negative-ion formation process. The experimental equipment and techniques utilized for emittance data acquisition and analysis, and evidence for a species-dependent effect in the emittances and brightnesses of the subject ion beams, are presented in this paper.
Two transition metal ions (Cu^2^+ and Co^2^+) and two rare earth metal ions (Ce^3^+ and La^3^+) were used as the assisted metal ions, respectively to prepare the transition metal and rare metal assisted Fe bimetallic amidoximated polyacrylonitrile (AO-PAN) fiber complexes. And their coordination configuration and visible light adsorption properties were examined by coordination number determination and UV-vis-DRS. Then the catalytic performance of these complexes was evaluated as the heterogeneous Fenton catalysts in Rhodamine B degradation by changing the nature and dosage of the assisted ions added. The results indicated that the incorporation of the assisted metal ions led to Fe bimetallic AO-PAN complexes with the more unsaturated configurations than Fe monometallic AO-PAN complex due ...
Presently, most charge state distributions produced with highly charged ion sources are predicted with models that approximate the ionization process with the Lotz formula. The Lotz ionization cross sections decrease approximately geometrically with increasing charge state except for ions with very few vacancies, for ions with very few electrons, and for electron impact energies which barely exceed the ionization energy. The geometrical decrease causes these models to predict a maximum abundance for most of the charge states, which is only weakly dependent on the charge state. Experimental results, however, yield much higher abundances for ions with an empty M shell than ions with a partly filled M shell. This difference is explained with indirect ionization processes that are neglected by the Lotz approximation, and normally can be neglected for the ionization of the L shell, but ...
The multi-faceted research effort of the EBIT (Electron Beam Ion Trap) program in N-Division of the Physics and Space Technology Department at Lawrence Livermore National Laboratory (LLNL) continues to contribute significant results to the physical sciences from studies with low energy very highly charged heavy ions. The EBIT program attracts a number of collaborators from the US and abroad for the different projects. The collaborations are partly carried out through participating graduate students demonstrating the excellent educational capabilities at the LLNL EBIT facilities. Moreover, participants from Historically Black Colleges and Universities are engaged in the EBIT project. This report describes EBIT work for 1995 in atomic structure measurements and radiative transition probabilities, spectral diagnostics for laboratory and astrophysical plasmas, ion/surface interaction studies, electron-ion ...
Investigations have been conducted to determine the feasibility of using collisional cooling for reducing the energy spreads and, consequently, the emittances of negative-ion beams. We have designed a gas-filled RF-quadrupole ion cooler equipped with provisions for retarding energetic negative ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to high energies after the cooling process. The device has been used to cool O{sup -} and F{sup -} ion beams with initial energy spreads, {Delta}E > 10 eV to final energy spreads, {Delta}E {approx} 2 eV FWHM. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been obtained. Experimental results show that electron detachment is the major loss mechanism for negative ions.
Investigations have been conducted to determine the feasibility of using collisional cooling for reducing the energy spreads and, consequently, the emittances of negative-ion beams. We have designed a gas-filled RF-quadrupole ion cooler equipped with provisions for retarding energetic negative ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to high energies after the cooling process. The device has been used to cool O{sup -} and F{sup -} ion beams with initial energy spreads, {Delta}E > 10 eV to final energy spreads, {Delta}E {approx} 2 eV FWHM. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been obtained. Experimental results show that electron detachment is the major loss mechanism for negative ions.
We present two applications of CR-39 to estimate biological effects of heavy ion irradiation. The accurate measurement of fluence of ions using CR-39 is indispensable to calculate the action cross sections for biological effects. Ions with 6 MeV/n at the Medium Energy Beam Course, HIMAC (NIRS) were extracted to the air, and degraded with the air. DNA and living cells were irradiated by ions with various specific energies at several air columns along with the Bragg curve. DNA strand breaks and cell killing were measured and the results were converted to the action cross sections using the fluence measured with CR-39 at the irradiation positions. Another example of the application of CR-39 is to identify whether the ions with a specific energy pass through the cell or stop within the cell. (author)
Shaped activated charcoal is modified by 02 and N2 processing for producing coal compounds with higher acidic or basic properties. Nitrated activated charcoal has properties of a weak anionite with a substantially increased ion exchange capacity with an increase in the concentration of the hydrogen ions in the electrolyte and adsorbs iodine ions well from aqueous solutions at a pH of less than 5. A layer of nitrated charcoal is a very effective sorbent in the process of dynamic sorption of iodine anions from acetic solutions of KI. It is also established that the sorption of iodine ions in the activated charcoal modified by 02 occurs in accordance with an ion exchange mechanism (and possibly, selective sorption). This refutes literature data which ascribe the determining participation in the process to the reaction of oxidation of iodides on the surface (Pv) of the coal into free ...
In analysis of hydrogen in metals and alloys by SIMS, control of the hydrogen blank mainly due to residual gases is a persistent problem. Contrarity, this problem becomes less important in case of deuterium analysis. The prescribed amounts of deuterium were introduced into a pure titanium and a beta-titanium alloy (Ti- 6.6wt%Fe) by the gas reaction method. Intensities of the various secondary ions sputtered from each sample were measured by the Hitachi Ion Microanalyzer with primary ions of Ar"+. Energy distributions of the various secondary ion species were measured with the energy window of about 15eV width. The effects of oxygen gas pressure in the target chamber and the bulk deuterium concentration on the shape of energy distribution curves are discussed. For all samples, intensity of D"- ions is higher than that of D"+ ions, especially at higher energy ...
A stiff skin forms on surface areas of a flat polydimethylsiloxane (PDMS) upon exposure to focused ion beam (FIB) leading to ordered surface wrinkles. By controlling the FIB fluence and area of exposure...Full Text Available
A multicusp magnetic field plasma surface ion source, normally used for H/sup -/ ion beam formation, has been utilized for the generation of high intensity, pulsed, heavy negative ion beams suitable for a variety of uses including tandem electrostatic accelerator/synchrotron injection applications. Sputter probe voltage limited total ion currents of 5.5, 8.2, 5.1 and 4.5 mA (peak intensity) have been produced from Au, Cu, Ni and CuO sputter probes, respectively. The mass distributions of these ion beams are found to be dominated by Au/sup -/, Cu/sup -/, Ni/sup -/ and O/sup -/ atomic species, respectively. The source offers the interesting prospect of providing cw negative ion beams at mA intensity levels of the commonly used semiconducting material dopants (e.g. B/sup -/, P/sup -/, As/sup -/ and Sb/sup -/) as well as O/sup -/ for isolation barrier formation. ...
We have investigated the characteristics of ion-beam-induced spontaneous etching (IBISE) of GaAs in Cl_2 ambient by using a Ga-focused ion beam (FIB) with an energy ranging from 3 to 15 keV. The etched depth of the irradiated region was more than 20 times greater than that of unirradiated region. When the sputtered depth by FIB irradiation amounted to around 8 A at each ion energy, the etched depth in Cl_2 ambient for 1 hour became saturated. The saturated etched depths were 450, 550, 750 and 800 A at the ion energy of 3, 5, 10 and 15 keV, respectively. The residual damage of the etched surface was also investigated by photoluminescence (PL) measurement. The maximal PL intensity was obtained at around the threshold dose of IBISE and increased with decreasing ion energy. The full recovery of PL intensity was observed at the ion energy of 3 keV after annealing at ...
SummaryTRPV1 is the founding and best-studied member of the family of temperature-activated transient receptor potential ion channels (thermoTRPs). Voltage, chemicals, and heat...Full Text Available
Analysis of results of an investigation into the structure of lithium salt aqueous solutions is presented. An anomaly in lithium ion behaviour in solutions at the structural level is noted. 40 refs., 3 tabs.
Amino acid transport in membrane vesicles of Bacillus stearothermophilus was studied. A relatively high concentration of sodium ions is needed for uptake of L-alanine (Kt = 1.0 mM) and L-leucine (Kt...Full Text Available
We show here sodium ion cycling between complex I from Klebsiella pneumoniae and the F1F0 ATP synthase from Ilyobacter tartaricus in a reconstituted...Full Text Available
BackgroundUnderstanding the interactions between ion channels and blockers remains an important goal that has implications for delineating the basic mechanisms of ion channel function...Full Text Available
A survey is given of the influence of surface deformations on heavy ion reactions. Emphasis is put on the effect of zeropoint fluctuations in the entrance channel and on the effect on grazing collisions in terms of an imaginary part of the scattering potential.
A survey is given of the influence of surface deformations on heavy ion reactions. Emphasis is put on the effect of zeropoint fluctuations in the entrance channel and on the effect on grazing collisions in terms of an imaginary part of the scattering potential. (orig.).
Rhizosphere acidification by Fe-deficient bean (Phaseolus vulgaris L.) plants was induced by trace amounts of divalent metal ions (Zn, Mn). The induction of this Fe-efficiency reaction...Full Text Available
This report discusses the following topics: Fusion-fission in light nuclear systems; High-resolution Q-value measurement for the {sup 24}Mg+{sup 24}Mg reaction; Heavy-ion reactions and limits to fusion; and Hybrid MWPC-Bragg curve detector development.
BackgroundThe precision in carbon ion radiotherapy depends on the calibration of Hounsfield units (HU) as measured with computed tomography (CT) to water equivalence. This calibration...Full Text Available
Charge-charge interactions dramatically influence the dissociation and proton transfer reactivity of large multiply protonated ions. In combination with tandem mass spectrometry, proton transfer...Full Text Available
Platinized cadmium sulfide powder suspended in a solution of sodium sulfite produces hydrogen efficiently by visible light. Sulfite ions are oxidized to sulfate and dithionate ions. 4 figures.
A parallel bundle of transmembrane (TM) alpha-helices surrounding a central pore is present in several classes of ion channel, including the nicotinic acetylcholine receptor (nAChR). We have modeled...Full Text Available
Transport of negative ion beams through plasma is reviewed. The effect of space charge on beam stability and beam emittance is discussed. The approaches to the beam transport problem developed at Los Alamos, Berkeley, Oak Ridge and Culham Laboratory are intercompared. (AIP)
The formation of porous structures of nanometre size (nanoporous structures) on germanium (Ge) surfaces by focused ion beam (FIB) irradiations was investigated using various FIB conditions such as ion species, irradiation energies, total fluences, fluence rates, and incident angles. FIB-irradiated regions were observed using a scanning electron microscope and an atomic force microscope. It is found that, using a focused Ga ion beam (Ga FIB) at an energy of 100 keV, the irradiated Ge surface swelled up to ion fluence of 2 x 10"1"7 cm"-"2 with nanoporous structures and then was etched for larger fluences. The shape of swollen nanoporous structures depended on the fluence rate and the incident angle of the Ga FIB. However, such porous structures were observed neither for low-energy (15-30 keV) FIB irradiations using Si and Au ions nor for high-energy (200 keV), heavy ...
The exposure of cells to several metal ions stabilizes HIF-1α protein. However, the molecular mechanisms are not completely understood. They may involve inhibition of hydroxylation by either...Full Text Available
In order to understand how matter 15 billion years ago in the form of quarks, gluons and leptons at a temperature of 2 (times) 10(sup 12) (degrees)K evolved to become today's Universe, the goal of relativistic and ultra-relativistic heavy ion physics is t...
The electrode structure of an inverted cesium sputtering negative ion source has been modified to produce a convergent Cs/sup +/ beam. The intensities of negative ion beams produced with this electrode structure are approximately an order of magnitude greater than previously obtained.
Each heartbeat requires precisely orchestrated action potential propagation through the myocardium achieved by coordination of about a million ion channels on the surface of each cardiomyocyte....Full Text Available
We have researched several new focused ion beam (FIB) micro-fabrication techniques that offer control of feature shape and the ability to accurately define features onto nonplanar substrates. These FIB-based processes are considered useful for prototyping, reverse engineering, and small-lot manufacturing. Ion beam-based techniques have been developed for defining features in miniature, nonplanar substrates. We demonstrate helices in cylindrical substrates having diameters from 100 {micro}m to 3 mm. Ion beam lathe processes sputter-define 10-{micro}m wide features in cylindrical substrates and tubes. For larger substrates, we combine focused ion beam milling with ultra-precision lathe turning techniques to accurately define 25-100 {micro}m features over many meters of path length. In several cases, we combine the feature defining capability of focused ion beam bombardment with ...
Focused ion beam (FIB) processes have been developed for Y--Ba--Cu--O superconductor films. A Y--Cu liquid metal ion source has been fabricated, using a Y_6_7 --Cu_3_3 eutectic alloy as the ion source. As-sputtered Y--Ba--Cu--O film etch rate ratios to GaAs(100) and Si(100) substrates are 0.28 and 1.4 for 130-keV Au"+ FIB ion etching, respectively. Y--Ba--Cu--O submicron patterns have been demonstrated by using FIB lithography and Cl_2 reactive ion beam etching. Moreover, a Y--Ba--Cu--O superconducting line with 4-#mu#m linewidth has been fabricated by annealing an as-sputtered Y--Ba--Cu--O line pattern. T/sub c/ control of Y--Ba--Cu--O film has been achieved by 200-keV Ne"+, using conventional ion implantation and 300 keV Si"+"+ FIB ion implantation.
Alkyl halides react rapidly with purines and pyrimidines in the presence of fluoride ion. Alkylation of thymidine leads to novel dimeric nucleoside derivatives bridged through N3. Alkylation of thymidine...Full Text Available
Focused Ion Beams are an important approach for nanostructure fabrication in the semiconductor industry and material sciences. Applications in sputtering and ion induced deposition of materials are investigated. The IMSA FIB system equipped with the high resolution Orsay Physics CANION M31plus ion column with current densities up to 10 A/cm"2 including a gas injection system is applied. In this work the ion beam induced chemical vapour deposition of tungsten, wherefore tungsten hexacarbonyl as precursor gas is used for a first investigation. Conductive tungsten-nanowires with smallest cross-section upon a substrate of Si and SiO_2 are produced. The ion beam parameters of this focused ion beam system are optimized for the metal deposition. A short insight in the theory of layer nucleation and growth induced by the ion beam during the metal ...
Biosorption of lead(II) ions from aqueous solution onto the seed husk of Calophyllum inophyllum was investigated in a batch system. Equilibrium, thermodynamics and kinetic studies were conducted by considering the effects of pH, initial metal ion concentration, contact time, and temperature. The results showed that the uptake of the metal ions increased with increase in initial metal ion concentration. The pH for optimum adsorption was 4 for the Pb(II) ions (q=4.86mg/g and 97.2% adsorption). Langmuir isotherm described the biosorption of Pb(II) ions onto the biomass (R^2=0.9531) better than the Freundlich model (R^2=0.7984), and the Temkin model (R^2=0.8761). Biosorption kinetics data obtained for the metal ions sorption were fitted using pseudo-first-order and pseudo-second-order. It was ...
The longitudinal and transverse dynamics of a heavy ion fusion beam during the drift compression and final focus phase is studied. A lattice design with four time-dependent magnets is described that focuses the entire beam pulse onto a single focal point with the same spot size.
Purpose:To investigate the clinical usage of dose verification of Helical Tomotherapy plans by using 2D-array ion chambers, and to develop an efficient way to validate the dose delivered...Full Text Available
The most important developments in gaseous detectors at LNL are reviewed. Some aspects of timing, pulse height and position resolutions of avalanche counters are reported. The experimental work on heavy-ion identification by Bragg curve spectroscopy is summarized.
Charge reduction electrospray mass spectrometry (CREMS) reduces the charge states of electrospray-generated ions, which concentrates the ions from a protein into fewer peaks spread over a larger...Full Text Available
The production of molecularly imprinted polymers (MIPs) for the recognition of C-terminal cholecystokinin pentapeptide (CCK-5) in the presence of metal ion is reported. The MIPs were produced under the same molar ratio of template to monomers (acrylamide, N,N'-methylene bisacrylamide) in the presence or absence of nitrilotriacetic acid-nickel (Ni-NTA) complex. Scanning electron microscopy images of MIPs were obtained in an attempt to correlate the adsorption characteristics with polymer's morphology. Subsequently Ni2+ was removed and substituted by other divalent ions such as Mg2+, Fe2+, Zn2+, Co2+ and Cu2+. It was found that polymers containing the metal ion complex with the order Fe-NTA, Ni-NTA and Cu-NTA presented lower dissociation constant values than the rest thus exhibiting stronger guest binding activity. The percentage of theoretical maximum binding sites Bmax was almost the same for these ...
The annealing behavior of the radiation damage in epitaxial Pd_2Si and NiSi_2 films on Si, due to the implantation of 100 keV Ar ions, is investigated by using the channeling technique with "4He ions. (U.K.).
An earlier representation of the radial distribution of dose about the path of a heavy ion in liquid water is modified and extended to include silicon, lithium fluoride, and sodium iodide. 6 refs., 5 figs., 1 tab.
Electrostatic nature of plant plasma membrane (PM) plays significant roles in the ion uptake and toxicity. Electrical potential at the PM exterior surface (ψ0o) influences...Full Text Available
In the context of sputtering experiments, studying the back-scattering of fast ion beams is a useful way to study inelastic ion-surface interactions, since then the trajectories and energies of the particles are well defined. This same argument holds for the scattering of fast molecular ions. We give a short account of our experiment where N"+_2 was scattered from a Ni(111) surface. The measured energy distributions of scattered N atoms are discussed with regard to vibrational and rotational energy transfer during scattering. (G.Q.).
Depending on their unique physical properties, proton and heavy ions have taken an irreplaceable role in modern means of tumor treatment. One-step process and two-step process physical models were employed to explain the mechanism of ion energy loss. The transport process of proton and "1"2C in water was simulated by Geant4 toolkit to study the physical properties of ion beam. The calculation results were discussed, which showed the advantages and disadvantages of proton and "1"2C in the medical application. (authors)
The methods of diffuse-reflection optical spectroscopy and EPR were used to study the state of molybdenum in catalysts prepared by impregnating ultrastable zeolite with molybdenum salt solutions and by mixing in the solid phase with MoCl/sub 5/. It has been shown that molybdenum introduced into zeolites in small amounts is found basically in the form of isolated hexavalent ions of molybdenum. In addition, Mo/sup 5 +/ and Mo/sup 4 +/ ions are also present. Heteropolycompounds also form. The molybdenum ions are most readily reduced in the zeolite prepared by impregnation with a solution of ammonium paramolybdate.
The sheath plasma characteristics changing with the negative bias applied to the substrate during electron cyclotron resonance plasma nitriding are studied. The sheath characteristics obtained by a Langmuir single probe and an ion energy analyzer show that when the negative bias applied to the substrate is increasing, the most probable energy of ions in the sheath and the full width of half maximum of ions energy distribution increase, the thickness of the sheath also increases, whereas the saturation current of ion decreases. It has been found from the optical emission spectrum that there are strong lines of N_2 and N_2"+. Based on the experiment results the mechanism of plasma nitriding is discussed
Separations of metal ions on the basis of Donnan dialysis across anion-exchange membranes should be possible if the receiver electrolyte composition favors the formation of selected anionic complexes of the sample metal ions. Moreover, such a separation has the possibility of being better suited from some applications than batch or column experiments with anion-exchange resins. The above hypothesis are tested on the platinum-group metal ions, Pt(IV), Rh(III), Pd(II), Ir(III), and Ir(IV). 13 references, 4 tables.
Selective removal of hexavalent chromium ions from aqueous solutions using a chitosan/gold nanoparticles composite film was demonstrated. Localized surface plasmon resonance (LSPR) was used to measure the interface stability and detect the incorporation of chromium ions over time. The effects of pH, ethylenediaminetetraacetic acid (EDTA), and various foreign ions such as trivalent chromium, sodium, calcium, phosphate, sulfate and chloride on the adsorption of hexavalent chromium were investigated. PMID:19381379
Two sources of negative ions are described. An rf source produces up to 14 ..mu..A beams of He/sup -/ by charge exchange in Rb vapor. The other Source of Negative Ions by Cesium Sputtering (SNICS) produces a wide variety of negative ion beams in the ..mu..A range. Two important features of SNICS are its simple, compact construction and its very good beam emittance (2 to 4..pi..mm mrad MeV/sup 1/2/). Both sources have lifetimes >200 hours and they are used extensively on the Wisconsin EN tandem.
Plasma generated in low-density vapor by a negative ion beam has been studied experimentally and computationally. We show that space charge neutralization of the beam occurs at very low vapor density, and that correspondingly the electron density may be much less than the beam and plasma ion densities. When there is a large local gas density, as in a charge changing cell, the resulting high electron density is also localized to the same region. Therefore, very few electrons will reach a negative ion accelerator even if it is placed one or two beam diameters from such a cell.
It is both experimentally and theoretically demonstrated that ion flow velocity at an arbitrary angle with respect to the magnetic field can be measured with a directional Langmuir probe. Based on the symmetry argument, we show that the effect of magnetic field on directional probe current is exactly canceled in determining the ion flow velocity, and obtain the generalized relation between flow velocity and directional probe currents valid for any flowing direction. The absolute value of the flow velocity is determined by an in situ calibration method of the probe. The applicability limit of the present method to a strongly ion-magnetized plasma is experimentally examined. (author)
We have undertaken a program which measures the photoelectron spectra of negative-ion beams. This experiment has afforded us direct information about these ions and the corresponding neutral radicals. Several ions and numerous radicals are believed to be crucial intermediates in combustion processes and flame chemistry. We have fabricated a spectrometer which directly measures electron affinities (EA). Knowledge of the EA and gas-phase acidity of a radical has enabled us to deduce several radical heats of formation and bond strengths.
The influence of motion of ions and electron temperature on nonlinear one-dimensional plasma waves with velocity close to the speed of light in vacuum investigated. It is shown that although the wavebreaking field weakly depends on mass of ions, the nonlinear relativistic wavelength essentially changes. The nonlinearity leads to the increase of the strong plasma wavelength, while the motion of ions leads to the decrease of the wavelength. Both hydrodynamic approach and kinetic one, based on Vlasov-Poisson equations, are used to investigate the relativistic strong plasma waves in a warm plasma. The existence of relativistic solitons in a thermal plasma is predicted.
Argon ion laser induced fluorescence measurements were carried out in a multipolar filament discharge with a broadband diode laser centered on 668 nm, which stimulated a transition from the metastable state in Ar(II) 3d4F7/2 to 4p4D05/2. The intensity of the induced fluorescence at 442 nm was maximized by the optimization of the discharge parameters and the laser power. From the recovery of the background fluorescence after the laser was turned off, the ion diffusion coefficient was deduced and compared with the result inferred from the experiments of ion acoustic wave (IAW) damping.
Ion acceleration has now been demonstrated with the IFA-2 collective ion accelerator system. The IFA-2 system is described, photoionization experiments are summarized, and ion results are presented. Using a 1 MeV electron beam and a 30 cm acceleration length, IFA-2 has produced 5 MeV H/sup +/, 10 MeV D/sup +/, and 20 MeV He/sup + +/. This means that accelerating fields of 33 MV/m over 30 cm have been achieved with a controlled collective accelerator for the first time.
The requirements for transporting high-current, negative-ion beams are presented with particular emphasis on applications involving negative-hydrogen-ion beams. In addition to the usual matching and steering problems, particular attention must be paid to beam emittance growth in the transport system. Depending on the application, a number of approaches have been developed using both magnetic and electric lenses. I discuss the design considerations for transporting and matching these beams to radiofrequency quadrupole accelerators, and present a survey of the various types of beamlines now used for negative-ion beams.
The requirements for transporting high-current, negative-ion beams are presented with particular emphasis on applications involving negative-hydrogen-ion beams. In addition to the usual matching and steering problems, particular attention must be paid to beam emittance growth in the transport system. Depending on the application, a number of approaches have been developed using both magnetic and electric lenses. I discuss the design considerations for transporting and matching these beams to radio-frequency quadrupole accelerators, and present a survey of the various types of beamlines now used for negative-ion beams.
The requirements for transporting high-current, negative-ion beams are presented with particular emphasis on applications involving negative-hydrogen-ion beams. In addition to the usual matching and steering problems, particular attention must be paid to beam emittance growth in the transport system. Depending on the application, a number of approaches have been developed using both magnetic and electric lenses. I discuss the design considerations for transporting and matching these beams to radiofrequency quadrupole accelerators, and present a survey of the various types of beamlines now used for negative-ion beams.
High-current implantation of Cu{sup {minus}} ions into silica glasses has been demonstrated using mA-class negative ion beams at 60 keV. Negative ion implantation has an advantage to alleviate specimen charging for insulating substrates and has attained high dose rates, up to 260 {micro}A/cm{sup 2}. Spherical Cu colloids form in the silica glasses without additional thermal annealing. Optical absorption and reflection of the implanted specimens vary with the current density, even at a fixed dose level. A beam-induced surface plasma may affect the high current implantation.
In terms of the kinetic theory of the interaction between the high-power short-time laser pulses with plasma based on the propagator plotting for the plasma particle distribution functions one studied the generation of the hot electrons and of the fast ions as the relativistic femtosecond laser pulses travelled through the supercritical density plasma. One performed calculations based on the various values of the laser pulse intensity, types of the multiple-charged ions, the plasma inhomogeneity degree. One studied the acceleration mechanisms both of the plasma electrons and ions
When energetic heavy ions traverse a medium, the amount of energy deposited by the ions is closely related to their effective charges. The charge-state fractions of these beams are obtained by solving rate equations for the electron loss and capture processes. By assuming local balance between electron loss and capture, the charge-state distributions, the averge equilibrium charge q, and other properties are obtained as functions of the incident beam velocity. The LET (linear energy transfer) of Ne and Ar ions with energies between 0.01 and 100 MeV/amu is calculatedted using their average equilibrium charge.
It is experimentally demonstrated that a relatively strong ion-rich sheath formed at a fixed negative bias of the grid can be changed to a rather weak ion sheath (sheath potential weakly retards electrons) only by increasing the discharge voltage in the system. At sufficiently high negative grid bias, an increase of discharge voltage enhances the ion collection current at the grid. An explanation is put forward in support of this experimental observation. A slight density enhancement with a fall in plasma electron temperature is also observed with the increasing negative grid bias. (authors)
The current status of research and development in the realm of physics and technology of collective ion acceleration in systems with a virtual cathode (VC) is reviewed. Three major acceleration methods and devices developed on their basis are considered: reflex triodes and their modifications, gas-filled vircators, and vacuum vircators with a Luce diode. Experimental data are outlined and the principal physical models interpreting these data are described. New ion acceleration techniques whose realization involves the production and disappearance of the VC are also discussed. All methods of collective ion acceleration are compared and the possible ways for the further development of this promising scientific field are highlighted. (reviews of topical problems)
An alkali-like ion interaction with inner electrons of an alkali-like ion leads to a significant increase in the photoionization cross section of the outer s electron. This occurs not only for ground-state ions with one s electron in the outer shell, but also when the outer s electron is in an excited state. The reason for this amplification, in addition to coherent enhancement in summing of the correlation amplitudes, is that the zero in the direct amplitude occurs below threshold. This leads to a constructive interference with the correlation amplitude above the photoionization threshold, in contrast to a destructive interference in the case of a neutral atom with the same electronic configuration, for which the zero occurs above threshold. Results of this research were published.
Separation of lithium isotopes was investigated by chemical ion exchange with a hydrous manganese(IV) oxide ion exchanger using an elution chromatography. The capacity of manganese(IV) oxide ion exchanger was 0.5 meq/g. The heavier lithium isotope was enriched in the solution phase, while the lighter isotope was enriched in the ion exchanger phase. The separation factor was determined according to the method of Glueckauf from the elution curve and isotopic assays. The separation factor of {sup 6}Li{sup +} -{sup 7}Li{sup +} isotope pair fractionation was 1.018.
One of the main problems related to optical thin film materials used in high power laser environments is the catastrophic damage caused to them due to laser irradiation. While the influence of ion bombardment on the optical properties of oxide thin films is now a well understood subject, the morphology and crystalline behaviour of these films under ion incidence is not so well studied. Hence, it is of great importance to investigate the effects of ion bombardment during growth on the microstructure and crystalline behaviour of oxide materials.
Nitrogens, Sulfurs, Isotopes, and Hydrocarbons Gases Elements Ions and Inorganic Acids Organic Compounds Co-eluting Organics Hopanes, Cholestanes, and Sterols Pesticides,...
During the present grant period we have continued our study of the photodetachment of atomic negative ions using cross-beam photoelectron detachment spectroscopy. The experimental technique involves the measurement of, under conditions of good energy and angular resolution, kinetic energies, yields and angular distributions of photoelectrons ejected from the interaction region between perpendicularly crossed laser and negative ion beams. 6 figs.
In this work, the principal continuum radiative emission processes, which occur during the penetration of ions in solids or gases, are resumed. The characteristics of the following processes are discussed: secondary electron bremsstrahlung (SEB), atomic bremsstrahlung (AB), and internuclear bremsstrahlung (INB). Recent advances of the ion channeling effects in crystal solids on the spontaneous radiative spectra are exposed. (A.C.A.S.).
The cathodic vacuum arc provides a means of producing large currents of positive ions of a wide variety of materials. These ions can be utilized to produce coatings with improved properties such as higher density and adhesion. The processing is particularly useful in reactive deposition of ceramic coatings having excellent stoichiometry. In this review, emerging aspects of the technology are emphasized.
Removal of radioactive ions was studied from low and medium level radioactive waste solutions by electrodialysis using ion exchange membranes. The test solutions contained "1"3"7Cs"+, "1"0"6Ru"3"+ or fission products (F.P.) as active ions and NaCl, Na_2SO_4 or Ca(NO_3)_2 as inactive coexisting salts. The decontamination factor of the active ions was in the order: "1"3"7Cs"+ (greater than 99%) > "9"0Sr"2"+ > F.P. > "1"0"6Ru"3"+. The dialysis time required to attain the saturation was the shortest for monovalent cations K"+, Cs"+ and Na"+, intermediate for divalent cation Sr"2"+, and the longest for trivalent cation Ru"3"+. The ratio of the decontamination factor of an active ion eta sub( a) to the desalination factor of an inactive ion eta sub( b) was nearly equal to unity for "2"4Na, "4"2K, "1"3"7Cs and "9"0Sr. On the other hand, the apparent selective ...
The structural variations of amorphous metals, such as Pd/sub 80/Si/sub 20/, with irradiation of helium ion, neutron, and gamma ray have been mainly pursued by the method of X-ray diffraction and thermal analysis. It should be noticed that the amorphous metals show a radiation resistance, that is, no remarkable structural changes under helium ion, neutron, and gamma ray irradiation.
We propose two schemes for the implementation of quantum discrete Fourier transform in the ion trap system. In each scheme we design a tunable two-qubit phase gate as the main ingredient. The experimental implementation of the schemes would be an important step toward complex quantum computation in the ion trap system.
To suppress space charge blowup in an ion beam passing through a photoneutralizer, it is necessary to introduce some background gas. An analysis is presented of the neutralization of a high-energy, >200-keV negative deuterium ion beam, exposed to photodetachment while in the presence of deuterium. With a gas thickness of <0.01 Torr.cm, the neutral fraction in the output beam is found to be about the same as that gotten from the photoneutralizer operating in vacuum. Neutral atom beam injection for plasma heating is discussed.
Binding of Cd/sup 2 +/ ions in aqueous solutions of statistical copolymers of acrylamide with cadmium acrylate with different content of ionogenic groups in copolymers was investigated by polarography, conductometry, viscometry and dialysis. It is shown that the degree of binding of Cd/sup 2 +/ ions increases with increasing of the content of ionogenic groups in the copolymer and with decreasing of ionic strength of the solution. The values of the degree of binding of Cd/sup 2 +/ ions obtained by polarography and dialysis show satisfactory agreement.
The possibility of applying the near infrared gas dynamic lasers (GDL) for neutralization of negative ion beams is examined. A criterion of neutralization is suggested. The use of the criterion makes it possible to select an optically active medium for a negative ion neutralization. To demonstrate the method media containing hydrohalogens as imitating molecules are taken. ((orig.))
One of the effective methods of deep modification of the surface of steels and alloys is the combination of ion implantation and plasma nitriding. In this work, the long-range effect is demonstrated in the case of combination of the effect of high- and low-energy ions of nitrogen on a martensitic steel for each ion implantation is usually not effective, and a titanium alloy used widely in industry.
High-brightness negative ion beams, especially O{sup -} beams, from a compact gaseous plasma source are studied to evaluate the suitability for high-resolution SIMS. Ion-optical calculations are made using the beam parameters from the new source. Results suggest that sub-100 nm spot with O{sup -} beam current of 10 pA is achievable. Beam focusing, the resulting beam current distributions at the target and the expected instrumental performance are discussed.
The estimation of numerical values of the mean distance of closest approach of ions, a, of heavy metal ion salts in aqueous solutions, determined from activity coefficients, as well as from different theoretical approaches, is presented and discussed.
Measurements of the double-electron-capture process in which a positive ion of iodine becomes a negative ion in a single collision with a magnesium atom are reported between 20 and 90 keV. The cross section is comparable to that for the rare gases and not as large as might be expected from a two-valence-electron atom. This process is probably insignificant in the production of negative ion beams using a magnesium-vapor target.
During this report period our research efforts have concentrated on studies of the dissociation reactions of model peptides and other biologically important molecules. In addition, a considerable amount of research effort has been directed toward improving the apparatus used for laser-ion beam photodissociation. The instrumental improvements include some changes on the original apparatus, but most of this effort involved designing a second generation laser-ion beam photodissociation instrument.
Nuclear Reaction Analysis (NRA) with deuteron ion beams has been used to probe for ion implanted nitrogen and carbon with high sensitivity in zinc oxide and silicon single crystals. The ion implanted N was measured using 1.4 MeV deuteron ion beams and was found to be in agreement with calculated values. The limit of detection for N in ZnO is 8x1014 ions cm-2. Raman measurements of the ion implanted samples showed three additional modes at 275, 504, and 644 cm-1 compared to the un-implanted ZnO crystals. The NRA and Raman results provided information on the N concentration, depth distribution, and structural changes that occur in dependence on the nitrogen ion fluences. The deuterium induced 12C(d,p)13C reaction was used to measure the carbon impurity/dose in ion implanted silicon. It was found that the use of a large ...
The original purpose of this research was an investigation into the use of slow space charge waves on weakly relativistic electron beams for ion acceleration. The work had three main objectives namely, the development of a suitable ion injector, the growth and study of the properties of slow space charge waves on an electron beam, and a combination of the two components parts into a suitable proof of principle demonstration of the wave accelerator. This work focusses on the first two of these objectives.
Cesium ions (Cs"+) are used for the production of the feed ions necessary to obtain Fourier transform mass spectra (FTMS). The molecule chosen for the initial study of this Cs"+ desorption ionization (DI-FTMS) was vitamin B-12 because of its nonvolatile, thermally labile character. 21 references.
A new, magnetically insulated negative ion source has recently been discovered which can produce pulsed negative ion beams (H/sup -/, Li/sup -/, and C/sup -/) with intensities of 100-300 A/cm/sup 2/ at 1-4 MeV. This source may provide the basis for a high energy neutral beam system for heating large tokamaks.
The plans for the CERN LHC heavy ion program in 2010 are for collisions of lead ions during the month of November at an energy about half of the final 5.5 TeV/nucleon. The advanced preparations are mostly for extrapolations of the measurements at the maximum energy previously available, Au + Au at 0.2 TeV/nucleon. Because of the large increase in energy, surprises can be expected. One new feature made possible by the increased energy and the excellent muon energy resolution of CMS will be the study of the yields of the excited states of the upsilon meson as a function of angle and centrality. Although the main emphasis will be on the QGP formed by the overlapping parts of the Pb ions, the spectator parts and the electromagnetic field outside of the ions, #gamma#-Pb and #gamma##gamma#, are also important.
The effect of swelling of crystalline Ge irradiated at room temperature with 30 keV Ga"+ focused ion beam (FIB) was studied by means of in situ FIB imaging, atomic force microscopy (AFM) and transmission electron microscopy (TEM). The swelling occurred in the surface region of amorphous damage layer which was formed during ion irradiation. The degree of swelling reaches values up to 10 times for an implantation dose of #approx#10"1"7 ions/cm"2. Cross-secitonal TEM examination showed that the swelling is due to formation of a porous layer with a honeycomb structure. (author). 8 refs., 4 figs.
A series of nine model ferritic alloys were ion irradiated at #propor to#300 C using 2.5 MeV He ions to a dose of 1.4 x 10"2"1 ion/m"2, which corresponds to #propor to#0.1 dpa at a depth of 2 #mu#m and #propor to#3.5 dpa at the peak damage region which occurs at about 4 #mu#m deep. The resultant changes in hardness as a function of depth were measured using a Nanoindenter "t"r"a"d"e"m"a"r"k. TEM was used to investigate the defect distributions. The effect of various solutes, Cu and N in particular, but Mn and Ti as well, on the change of hardness and the defect distribution due to the ion irradiation are discussed. (orig.).
The distribution profiles of the chemical structural changes induced in low density polyethylene(LDPE) irradiated by various ion-beams were obtained by micro-FT-IR measurement. Predominant species induced by ion-beam irradiation were trans-vinylene, hydroxyl group and carbonyl group. It was found that the depth profiles of these species resemble the Bragg curve, but they are rather different from the depth profile of the stopping power calculated by TRIM code. The terminal of the chemical reaction was observed to be deeper than the range calculated by TRIM code for all ion particles. This suggests that the energy profile in the region which the energy of the ion particle becomes lower is very complicated. (author).
Neopentane, because of its unique structural features, was found to be a useful probe for the assay of the acidity of various zeolites. The C-C bond was attacked by catalyst protons yielding CH/sub 4/ and the isobutyl carbenium ion in equal quantities. The latter either decomposed to produce isobutene or underwent secondary reactions. New avenues for reaction were opened with isobutane. The reaction of the Bronsted protons with the tertiary CH bonds produced H/sub 2/ and the same isobutyl carbenium ion. Hydride ion transfer of the same tertiary hydrogen to existing carbenium ions also occurred and the results showed that about half of the reaction was carried by this pathway. As with Neopentane, the C-C bond could also be attacked yielding the sec-propyl carbenium ion. These tools are being further developed.
The operation of the negative ion based NBI system for JT-60U has been progressed since 1996. Most of the efforts in the operation for increasing beam power and energy have been concentrated to get over the troubles, caused by surge energy at the moment of the accelerator break-down, in the ion sources and high voltage power supplies. The ion source for the N-NBI, so far, has accelerated negative ion beams of 14.3 A at 380 keV with deuterium and 18.5 A at 360 keV with hydrogen against the target of 22 A. The neutral beam power injected into JT-60U has already reached 5.2 MW at 350 keV for 0.7 sec with deuterium. (author)
The profile of focused boron ion beam (FIB) from a liquid metal ion source was determined by MOS device characteristics and resist exposure experiments. A focused boron ion beam was line-scanned into the middle of the channel region along the source to drain direction of a MOSFET, and the effective channel width is determined from electrical measurements. PMMA resist was also exposed by a line-scanned boron FIB and the developed contour was observed by a SEM. The profile of the focused boron ion beam with a diameter of around 0.2 ..mu..m was determined by these two methods and it was found to have about a 1 ..mu..m wide tail at around three orders of magnitude below the peak current density region. The profile difference between the two measurements are attributed to the boron diffusion in silicon by subsequent heat-treatments during device fabrication.
By using Bragg curve spectroscopy, one can measure atomic number and energy of high energy heavy ions stopping in a gas-filled ionization chamber with longitudinal electric field. In this paper, we report on the results obtained with an isobutane filled detector. An energy resolution of 0.8% fwhm and a Z resolution of 2.7% fwhm were achieved for elastically scattered 300 MeV /sup 40/Ar ions. We study the Bragg peak amplitude dependence on the energy of the incoming ions, a dependence presumably due to the Frisch grid screening inefficiency. The corrected Bragg peak spectrum of inelastically scattered 300 MeV /sup 40/Ar ions exhibits a satisfactory Z separation around Z = 18.
By using Bragg curve spectroscopy, one can measure atomic number and energy of high energy heavy ions stopping in a gas-filled ionization chamber with longitudinal electric field. In this paper, we report on the results obtained with an isobutane filled detector. An energy resolution of 0.8% fwhm and a Z resolution of 2.7% fwhm were achieved for elastically scattered 300 MeV "4"0Ar ions. We study the Bragg peak amplitude dependence on the energy of the incoming ions, a dependence presumably due to the Frisch grid screening inefficiency. The corrected Bragg peak spectrum of inelastically scattered 300 MeV "4"0Ar ions exhibits a satisfactory Z separation around Z = 18. (orig.).
Modifications of the structure and mechanical properties in LiF crystals irradiated with MeV-energy Au ions have been studied using nanoindentation, atomic force microscopy and optical spectroscopy. The nanostructuring of crystals under a high-fluence irradiation (above 1013 ions/cm2)?was?observed. Nanoindentation tests show a strong ion-induced increase of hardness (up?to 150?200%), which is related to the high volume concentration of complex color centers, defect aggregates, dislocation loops and grain boundaries acting as strong barriers for dislocations. From the?depth profiling of the hardness and energy loss it follows that both nuclear and electronic stopping mechanisms of MeV Au ions contribute to the creation of damage and hardening. Whereas the electronic stopping is dominating i...
The performance of spherical Resorcinol-Formaldehyde ion-exchange resin for the removal of cesium from alkaline radioactive waste solutions has been investigated through computer modeling. Cesium adsorption isotherms were obtained by fitting experimental data using a thermodynamic framework. Results show that ion-exchange is an efficient method for cesium removal from highly alkaline radioactive waste solutions. On average, two 1300 liter columns operating in series are able to treat 690,000 liters of waste with an initial cesium concentration of 0.09 mM in 11 days achieving a decontamination factor of over 50,000. The study also tested the sensitivity of ion-exchange column performance to variations in flow rate, temperature and column dimensions. Modeling results can be used to optimize design of the ion exchange system.
This paper reports the results of leaching experiments conducted with and without Thiobacillus ferroxidans at the same conditions in solution. The extent of leaching of ZnS with Bacteria is significantly higher than that without bacteria at high concentrations of ferrous ions. A porous layer of elemental sulfur is present on the surfaces of the chemically leached particles, which no sulfur is present on the surfaces of the bacterially leached particles. The analysis of the data using the shrinking-core model shows that the chemical leaching of ZnS is limited by the diffusion of ferrous ions through the sulfur product layer at high concentrations of ferrous ions. The analysis of the data shows that diffusion through the product layer does not limit the rate of dissolution when bacteria are present. This suggests that the action of T.ferroxidans in oxidizing the sulfur formed on the particle surface is to remove the barrier ...
By using megaelectronvolt "4He ion backscattering techniques and transmission electron microscopy, the authors have investigated the interactions of ion beams with thin film structures in a number of silicide-forming systems. The mixed layer was found to be an equilibrium compound for near-noble metals and an amorphous phase for refractory metals. Differences in behavior have also been observed in near-noble metal systems. For palladium, the Pd_2Si phase grew with ion dose and remained crystalline up to high dose. For nickel, the compound Ni_2Si was formed initially and became amorphous on prolonged irradiation. All the results indicate the significance of atomic mobility at target temperatures in determining the phase formation and in explaining the sensitivity of the silicides to ion bombardment. (Auth.).
During helium beam fuelling experiments in JET, distinctive anisotropic features have been observed in the velocity distribution function describing both fast and thermal alpha particle populations. During the initial fuelling phase the central helium ion temperature observed perpendicular to the magnetic field is higher than the central electron temperature, while the central helium ion temperature observed parallel to the magnetic field is lower than or equal to the central electron temperature. In order to verify temperature measurements of both perpendicular and parallel lines of sight, other independent methods of deducing the ion temperature are investigated: deuterium ion temperature, deuterium density, comparison with neutron rates and profiles (influence of a possible metastable population of helium). 6 refs., 7 figs.
An ion processing element employing composite media disposed in a porous substrate, for facilitating removal of selected chemical species from a fluid stream. The ion processing element includes a porous fibrous glass substrate impregnated by composite media having one or more active components supported by a matrix material of polyacrylonitrile. The active components are effective in removing, by various mechanisms, one or more constituents from a fluid stream passing through the ion processing element. Due to the porosity and large surface area of both the composite medium and the substrate in which it is disposed, a high degree of contact is achieved between the active component and the fluid stream being processed. Further, the porosity of the matrix material and the substrate facilitates use of the ion processing element in high volume applications where it is desired to effectively process a high ...
The influence of the regimes of modification of carbon fibers by an argon ion beam on the change in the angle of their wetting by an epoxy oligomer has been investigated. It has been shown that ion-beam treatment of carbon fibers leads to a considerable decrease in the wetting angles (the difference between the wetting angles for non modified and modified fibers is up to 32.2-38.7). Accordingly, there is also an increase in the value of the equilibrium work of adhesion by 36.2-41.6% in the contact zone. It has been established that ion-beam treatment of carbon fibers by argon ions leads to an increase in the shear strength when microplastics based on them are formed. (authors)
The formation of nanoparticles during the radiation-induced chemical reduction of silver ions, copper ions, and nickel ions in films based on poly(acrylic acid)-poly(ethylenimine) complexes are studied via electron microscopy. This approach allows preparation of composites containing nanoparticles that are randomly distributed in the polymer matrix and materials with a regular spatial distribution of nanoparticles across the film thickness and in subsurface layers. The structure of metal-polymer hybrid materials is dependent on the irradiation conditions, the type of reduced metal ions, and their initial content in polymer matrices. The ratio between the rate of nucleation and the rate of growth of nanoparticles in the matrices of interpolyelectrolyte complexes depends on the intensity of ...
A focused ion beam (FIB) system produces a final beam spot size down to 0.1 .mu.m or less and an ion beam output current on the order of microamps. The FIB system increases ion source brightness by properly configuring the first (plasma) and second (extraction) electrodes. The first electrode is configured to have a high aperture diameter to electrode thickness aspect ratio. Additional accelerator and focusing electrodes are used to produce the final beam. As few as five electrodes can be used, providing a very compact FIB system with a length down to only 20 mm. Multibeamlet arrangements with a single ion source can be produced to increase throughput. The FIB system can be used for nanolithography and doping applications for fabrication of semiconductor devices with minimum feature sizes of 0.1 .mu.m or less.
A focused ion beam (FIB) system produces a final beam spot size down to 0.1 {mu}m or less and an ion beam output current on the order of microamps. The FIB system increases ion source brightness by properly configuring the first (plasma) and second (extraction) electrodes. The first electrode is configured to have a high aperture diameter to electrode thickness aspect ratio. Additional accelerator and focusing electrodes are used to produce the final beam. As few as five electrodes can be used, providing a very compact FIB system with a length down to only 20 mm. Multibeamlet arrangements with a single ion source can be produced to increase throughput. The FIB system can be used for nanolithography and doping applications for fabrication of semiconductor devices with minimum feature sizes of 0.1 m or less. 13 figs.
Shadow effect was used for investigating damage of uranium dioxide monocrystal. The dependence of shadow minimum parameters on fluence of "2"2Ne ions with 172 MeV energy was followed when detecting fission fragments. Ion dose responsible for sufficient microdamage of lattice structure, included into the classification of heavy ion damage effect on monocrystals was determined. The problem of radiation intensity effect on the character of occurred damages was studied. It was established that macroscopic sample failure, caused by generation of considerable mechanical stresses in monocrystal under beam effect could be observed along with microdamages of lattice structure at ion flux density >10"1"2 cm"-"2Xs"-"1.
N-type crystalline Si (100) implanted with 5 keV B ions was subsequently irradiated with MeV Si, O and F ions. The B atom profiles were measured by means of secondary ion mass spectrometer after the treatment of rapid thermal annealing. The results show that the transient enhanced diffusion of B atoms is effectively limited by the post-implantation of high energy ions at high dose. At the same irradiation conditions, it is found that the existence of a SiO_2 layer in the near surface of Si is even more effective in suppressing the transient enhanced diffusion of the doped B atoms. The results are qualitatively discussed in combination with the analyses of RBS/c measurements and calculation of the DICADA code
Pd/sub 2/Si formation at the Pd-Si interface induced by irradiation with ions having a wide range of nuclear energy of deposition density has been investigated. It is found that the thickness of the silicide layer formed by irradiation is proportional to the ion fluence for irradiation with ions having low energy-deposition densities, while it is proportional to the square root of the fluence for irradiation with ions having energy-deposition densities. The results indicate that Pd/sub 2/Si formation is reaction limited when the energy-deposition density at the interface is low and is diffusion limited when it is high. The results are compared with the phenomenological theory developed by Horino et al. and it is shown that such a dependence of the limiting processes on the energy depositon density is induced when the diffusion is thermally activated while the reaction at the interface is ...
An apparatus capable of producing current or voltage controlled positive and negative ion beams in 1-atm oxidizing and nonoxidizing ambients between 25/sup 0/ and 950 /sup 0/C is presented. The apparatus utilizes a point-to-plane corona discharge in the gas phase. Room-temperature experiments revealed that the small differences in ion beam shape between the two polarities is primarily due to the difference in applied voltage required to produce the same current for the two polarities. Due to increased ion mobility and decreased threshold voltage at higher temperatures, a slight broadening of the ion beam current-density profiles for both positive and negative ions is predicted.
Arsenic and hydrogen ions produced from a mixture of arsine and hydrogen gas were implanted with a dose of 3 x 10{sup 15} As{sup +} ions/cm{sup 2} into silicon using an ion-shower implanter. The dominant ionic species implanted into the silicon were As{sub 2}H{sup +}, AsH{sup +}, H{sub 5}{sup +}, and H{sub 3}{sup +} ions. Arsenic atoms diffused into the silicon with large diffusion coefficients during annealing at 700 and 800 C. However, when the implanted silicon was annealed at 900 C, the arsenic atoms diffused into a deeper region in the silicon with a very small diffusion coefficient that was independent of concentration. (Abstract Copyright [2003], Wiley Periodicals, Inc.)
This paper reports on a series of experiments performed to examine the ability of ion beam assisted thermal deposition to produce good adhesion of Au metallization on GaAs left-angle 100 right-angle substrates. A study of the influence of Ar ion-assisted thermal deposition of the Au films as well as in situ pre-sputtering of the GaAs surface with low-energy Ar ions prior to thermal deposition, shows that strong adhesion can be achieved without resorting to chemical cleaning. The substrate temperature and the relative flux of Ar ions to incident Au atoms were varied in order to correlate these parameters with film adhesion. The interfaces of films processed under these various conditions were examined by XTEM, RBS and XPS. Orientation texture was studied by x-ray diffraction (XRD).
The effects of O and C ion implantation with different implantation doses on the yellow luminescence (YL) from unintentional doped n-type GaN have been studied by the photoluminescence (PL) spectra. O and C ions were implanted in the GaN samples with different doses from 1.0 x l013 to 1.0 x l017cm-2. Post-annealing was done in a quartz open-tube furnace under flowing N2 gas for 30 min at 950 degree C. By comparing with N ion implanted samples, it is assumed that different deep-level centers involving in the YL were produced in GaN after O and C ion implantation. In addition, with a dose of 1017 cm-2, the concentration of deep C centers involving in the YL was enhanced markedly. (authors)
Collective methods of ion acceleration using intense relativistic electron beams (IREB) have stimulated a great deal of interest in the past few years. The main virtue of an IREB collective ion accelerator is the high internal electric field strength. The primary drawback has been an insufficient ion energy gain or inadequate scaleability. An extensive study for generating a high quality electron beam has been done and is presented in Section 2. In Section 3 an intense ion injector study was conducted by the method of computer simulation. The last addition to the proposal was a design for producing a toroidal magnetic field. This field will be needed in a future study of high energy and high current electron beams.
A large negative ion source for JT-60U produces high current ion beam from a wide extraction area of 45 cm x 110 cm. On the other hand, a cross-sectional area of the negative ion based neutral beam (NNB) injection port on JT-60U is narrow, about 50 cm x 60 cm. In order to inject the neutral beam at a high geometric efficiency, i.e. to suppress beam loss in the beamline, it is necessary to steer the beam for both compensation of undesirable beam deflection in extractor and focusing of the beam. For the JT-60U, two methods are provided for the required beam steering. Among them the results of beam steering experiment by aperture displacement and the design study are summarized in the present report. The experiment was carried out with 400 keV negative ion source, which has the three stage accelerator of similar structure as the JT-60U ion source, at Negative Ion ...
Type 304 stainless steel (SS) specimens sensitised at 873 K and 973 K for 1, 10 and 100 hours respectively were ion implanted using a 150 keV accelerator at an energy of 70 keV in two different doses of nitrogen namely 1 x 10"1"6 to 1 x 10"1"7 ions/cm"2. Ion implantation at 1 x 10"1"6 ions/cm"2 did not show any improvement in pitting resistance, however, the specimens implanted at 1 x 10"1"7 ions/cm"2 showed significant increase in pitting corrosion resistance when potentiodynamic anodic polarisation studies were carried out in acidic chloride medium. For specimens aged at 873 K, nitrogen ion implantation at 1 x 10"1"6 ions/cm"2 increased the intergranular corrosion susceptibility compared to that of unimplanted specimens. However, at the dose of 1 x 10"1"7 ions/cm"2, insignificant IGC attack was noticed. The IGC ...
Previously, we demonstrated that the lithium ion conduction in the perovskite-type manganese fluoride is attributed to counter cation-site vacancy mechanism. The divalent counter cation-doped KxBa(1-x)/2MnF3 was theoretically predicted as the lithium ion conductor in the perovskite-type manganese fluoride. In this study, we considered the oxygen doping for KxBa(1-x)/2MnF3 to realize the higher lithium ion conductivity. It is because lithium ion forms the stronger ionic bond with the doped oxygen anion. The hybrid-DFT calculations were performed to investigate the lithium ion conduction in the oxygen-doped KxBa(1-x)/2MnF3. The calculation results were discussed from the viewpoints of the potential energy curve, electron densities, and charge and spin densities. The effect of the lithium ion...
The energy distribution of ion beams is important especially for low energy ion beam applications. The energy distributions of negative-ion beams produced through secondary ion emission by sputtering were measured and compared with theoretically estimated distributions by use of four different negative-ion production probability equations (modified surface ionization model, exponential velocity dependence model, and our modified exponential velocity dependence models (modified decaying factor model and combination model of velocity dependence and surface ionization)). In the measurements, the energy distributions of C"- and Ag"- beams had a peak at a few to several eV and the full width at half maximum were 15 eV and 11 eV, respectively. These results could be well explained by the estimated distributions by virtue of our combination model or the modified surface ionization model. ...
Thinning specimens to electron transparency for electron microscopy analysis can be done by conventional (2-4 kV) argon ion milling or focused ion beam (FIB) lift-out techniques. Both these methods tend to leave 'mottling' visible on thin specimen areas, and this is believed to be surface damage caused by ion implantation and amorphisation. A low energy (250-500 V) Argon ion polish has been shown to greatly improve specimen quality for crystalline silicon samples. Here we investigate the preparation of technologically important materials for nanoanalysis using conventional and lift-out methods followed by a low energy polish in a GentleMill"T"M low energy ion mill. We use a low energy, low angle (6-8 deg.) ion beam to remove the surface damage from previous processing steps. We assess this method for the preparation of technologically important materials, such ...
Microfabrication processes for Y-Ba-Cu-O films have been investigated, using ion-beam techniques. High-T_c superconducting lines as narrow as 0.8 #mu#m have been fabricated from epitaxial YBa_2Cu_3O_7 _- _y films by Ar ion-beam etching (IBE), combined with focused ion-beam (FIB) lithography. The resulting lines, 1.3 #mu#m wide and 2 mm long, showed a zero resistance temperature of 81 K and a critical current density of 1.9 x 10"4 A/cm"2 at 77.3 K. Maskless etching was carried out using 130-keV au"+ focused ion-beam (FIB) with a 0.1-#mu#m-diameter beam. A 50-nm-thick film was patterned into 0.3-#mu#m-wide lines at a dose of 5 x "1"6 ions/cm"2. In comparison with Ar IBE, Cl_2 reactive ion-beam etching (RIBE) exhibited an enhancement effect in sputtering yield. Ion implantation with 300-keV Si"+ "+ FIB also indicated the possibility to produce ...
Measurements of the small-, intermediate-, and large-ion concentrations and the atmospheric electric conductivity of both polarities have been made over the Arabian Sea on four cruises of ORV Sagarkanya during the Arabian Sea Monsoon Experiment (ARMEX)during the monsoon and pre-monsoon seasons of 2002 and 2003. Seasonally averaged values of the total as well as polar conductivity are much higher during the monsoon than pre-monsoon season. Surprisingly, however, the concentration of small ions are less and those of large and intermediate ions are more during the monsoon than pre-monsoon season. The diurnal variations observed during the pre-monsoon season show that the nighttime small ion concentrations are about an order of magnitude higher than their daytime values. On the contrary, the daytime concentrations of the intermediate and large ions are much higher than those of their ...
General trends in integrated circuit technology toward smaller device dimensions, lower thermal budgets, and simplified processing steps present severe physical and engineering challenges to ion implantation. These challenges, together with the need for physically based models at exceedingly small dimensions, are leading to a new level of understanding of fundamental defect science in Si. In this article, we review the current status and future trends in ion implantation of Si at low and high energies with particular emphasis on areas where recent advances have been made and where further understanding is needed. Particularly interesting are the emerging approaches to defect and dopant distribution modeling, transient enhanced diffusion, high energy implantation and defect accumulation, and metal impurity gettering. Developments in the use of ion beams for analysis indicate much progress has been made in one-dimensional ...
The possibility of smoothening aspherical X-ray mirrors by irradiation of the surface with a low-energy ion beam is investigated. Nanofocusing being the primary application of these mirrors the ion beam conditions must be optimized to achieve a surface roughness of the order of 0.1-0.2 nm. To address this issue a first study was performed on silicon flat substrates etched using ion energies ranging from 400 to 1200 eV. A second study consisted of eroding the silicon surface while varying the ion grazing incidence angle between 10 deg. and 90 deg. for a fixed value of the ion energy. The surface topography of the samples was characterized at various scales using atomic force microscopy (probed area: 1-10 ?m2), interferential optical microscopy (probed area: 1 mm2) and X-ray scattering (probed area: 100 mm2). Finally, a study by AFM of the evolution of the surface finish level of a ...
We report a study of the physical characteristics of the pillars of C, Pt and W grown by 10-30 keV Ga focused ion beam (FIB) as a function of Ga ion flux, and present a quantitative analysis of the elements using energy-dispersive analysis of X-rays (EDAX). All the FIB grown pillars exhibit a rough morphology with whisker like protrusions on the cylindrical surface and broadening of the base as compared to the nominal size. For a constant fluence, the height of the pillar initially increases and then reduces after going through a maximum as a function of ion flux in all the cases. The compositional analysis shows good metallic quality for Pt structures but reveals significant contamination of Ga in C and Ga and C in W structures at higher ion fluxes. Explanation to all these observations has been sought in the light of secondary ion and electron effects and the different processes ...
Two measurement methods to determine the rate of neutral free radical production by the photo-deionization of negative ion beams (PDINIB) are introduced. These methods, namely, photoelectron-current measurement by low-frequency electro-modulation probe (PMMP) and measurement of decrease in the negative-ion beam current (DNIC) were employed to evaluate the production rate in a trial surface-processing apparatus developed in the author's laboratory utilizing a steady-flux refined beam of neutral free radicals (RBNR) produced by the PDINIB procedure. A {sup 63}Cu{sup -} negative ion beam of kinetic energy E{sub i} varied up to 15 keV was irradiated with a 514.5 nm visible light beam from a 25 W CW Ar{sup +} ion laser. The detection limit of the production rate by the PMMP setup was as high as 6 x 10{sup 9} s{sup -1} under the condition that E{sub i}=15 keV, the negative-ion ...
Studies have been conducted to determine the feasibility of using collisional cooling for reducing emittances and energy spreads in negative-ion beams to levels commensurate with effective isobaric purification with conventional high-resolution electromagnetic isobar separators as required for use at the Holifield Radioactive Ion Beam Facility (HRIBF). We have designed a gas-filled radio frequency quadrupole ion cooler equipped with provisions for retarding energetic negative-ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to initial energies after the cooling process. The device has been used to cool several ion beams with initial energy spreads, {delta}E>10 eV to final energy spreads, {delta}E{approx}2 eV FWHM, including O{sup -} and F{sup -}. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been ...