WorldWideScience
1

Chamberless residential warm air furnace design  

Energy Technology Data Exchange (ETDEWEB)

This brief paper is an introduction to the concept of designing residential warm air furnaces without combustion chambers. This is possible since some small burners do not require the thermal support of a combustion chamber to complete the combustion process.

1996-07-01

2

Roof slab cooling device in a FBR type reactor  

International Nuclear Information System (INIS)

Purpose: To obtain a roof slab cooling device capable of retaining cooling performance even in a case of electric power supply stop or failure and effective from economical point of view. Constitution: Atmospheric air is introduced into the cooling chamber of a proof slab and spontaneously passed to a exit pipeway connected to a stack thereby cooling the roof slab. Specifically, atmospheric air entered from the inlet pipeway is introduced to the cooling chamber and absorbs heat generate from the inside of the reactor container. Warmed air is sucked from the exit pipeway and then released into the atmosphere passing through the stack. The air cools the roof slab during circulation due to spontaneous passage and keeps the slab at a low temperature. Since the air is passed spontaneously, no power such as for a blower is required at all and, if the electric power supply should be lost, the cooling power can be maintained as it ...

1986-05-16

4

Geothermal heat-pump systems of heat supply  

International Nuclear Information System (INIS)

The data on the multilayer operation of the objects, located in the climatic conditions of the central area of Russia and equipped with the geothermal heat-pumping systems of the heat supply are presented. The results of the analytical studies on evaluating the geothermal heat-pumping systems of the heat supply integration efficiency into the structure of the energy supply system, prevailing in the country, are presented

2004-06-01

5

Optimal thermodynamic heat transfer  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a set of heuristics useful for optimal design of heat-exchange networks and integrated heat and power systems. These heuristics consolidate other approaches reported in the literature in a formalism useful for design purposes.

1989-06-01

6

Alterations in resting oxygen consumption in women exposed to 10 days of cold air  

Energy Technology Data Exchange (ETDEWEB)

Repeated exposure to cold air reduces the metabolic response to cold air exposure in man. The purpose of this investigation was to measure the change in resting metabolic rate (RMR) with exposure to 22C air and 4C air during a 12 day period. Four women sat in 22C air for 45 min followed by 45 min in 4C air each day for ten days. The authors measured RMR during a 45 min period in 22C air followed by 45 min in 4C air on four days. All subjects began their morning exposures on a Monday within 2 days of the onset of menses completing the study on a Friday, 12 days later. Subjects dressed in a T-shirt, shorts and cotton socks. During 45 min of exposure to warm air, RMR remained steady at 10% of VO{sub 2peak} on Day 1 and 10% on Day 5. RMR during exposure to warm air significantly increased to 13% of VO{sub 2peak} on Day 8 and remained elevated at 13% on Day 12. During exposure to cold air RMR peaked at 31% ...

1991-03-11

7

Thermodynamic analysis of a hybrid geothermal heat pump system  

British Library Electronic Table of Contents (United Kingdom)

A thermodynamic analysis of a hybrid geothermal heat pump system is carried out. Mass, energy, and exergy balances are applied to the system, which has a cooling tower as a heat rejection unit, and system performance is evaluated in terms of coefficient of performance and exergy efficiency. The heating coefficient of performance for the overall system is found to be 5.34, while the corresponding exergy efficiency is 63.4%. The effect of ambient temperature on the exergy destruction and exergy efficiency is investigated for the system components. The results indicate that the performance of hybrid geothermal heat pump systems is superior to air-source heat pumps.

2011-01-01

8

Binary heat pump system. Binary heat pump system  

Energy Technology Data Exchange (ETDEWEB)

This technical report describes an outline, features, total energy efficiency, and specifications of binary heat pump system. A closed circuit distributed water heat source heat pump method is employed in the binary heat pump system. Since the circulating water, which is adjusted at a constant temperature, is used as the heat source of the indoor unit, a stable performance can be obtained regardless of outside atmospheric temperature. The binary heat pump system is mainly composed of a center heat pump unit, indoor heat pump unit, heat source water pipes, and circulating pump. The center heat pump unit and the indoor heat pump unit are connected with each other by the heat ...

1993-11-30

9

Literature and patent searches on the subject of controllable heat transfer. Final report. Literatur- und Patentrecherche zum Thema Schaltbarer Waermedurchgang. Abschlussbericht  

Energy Technology Data Exchange (ETDEWEB)

The possibility of switching the heat transfer consists of varying heat transfer surfaces and making the heat transfer temporarily more intensive. Heat tubes prove to be particularly suitable, which must be exposed to a heat carrier fluid or removed from its effect for switching the heat transfer. This report gives a survey of the possibilities of switching heat flows and for making the heat transfer more intensive. Further, the report contains a survey of patents limited to heat transfer in the fields of cooling internal combustion engines and exhaust systems. (orig.) With 17 figs., 183 refs.

1989-01-01

10

Development of a geothermal heat pump. Final report  

Energy Technology Data Exchange (ETDEWEB)

In the development of a geothermal heat pump a water source heat pump was connected to a 1-1/2'' water line, 2200' long, buried in an endless loop 10' deep. The system is closed, circulating the same water continuously through the heat pump back to the field again. This water line 10' deep is the geothermal heat source. No matter how cold the air temperature gets on a winter day the water temperature to the heat pump will always be above 45/sup 0/F. This system has efficiently heated our house the past year using no supplemental heat.

1981-11-02

11

Emergency core cooling device for a reactor  

International Nuclear Information System (INIS)

Purpose : To obtain an emergency core cooling device in a FBR type reactor by utilizing heat pipes which are not actuated at usual operation condition but actuated reliably upon emergency. Constitution : A system for injecting heat medium into heat pipes is provided. By injecting the heat medium into the heat pipes upon emergency to actuate the heat pipes, the reactor core is cooled. During normal reactor operation, the inside of the heat pipes is evacuated from a vacuum pump and no heat medium is filled therein, whereby unnecessary heat loss during the normal operation can be prevented. (Ikeda, J.).

1982-01-24

13

Heating and hot water: the installations; Chauffage et eau chaude: les installations  

Energy Technology Data Exchange (ETDEWEB)

This book brings recommendations and information on the choice and the operating of heating systems and domestic hot water production in order to better choose the house, to better use the heating and to preserve the environment. General notions on the different heating systems and their operating on the renewable energies used and the heating emitters offer advices for the purchase of a house. (A.L.B.)

2005-07-01

14

A parametric study on the exergoeconomic assessment of a vertical ground-coupled (geothermal) heat pump system  

Energy Technology Data Exchange (ETDEWEB)

An exergoeconomic model of a vertical ground-source heat pump residential heating system presented in this study uses exergy and cost energy mass (EXCEM) methods. The data obtained from a ground-source heat pump (GSHP) residential heating system installed at the Solar Energy Institute, Ege University, Turkey, are utilized for calculations at different reference temperature values in the range 0-25{sup o}C. The performance of the geothermal heat pump residential heating system is evaluated to indicate how exergoeconomic parameter values change with system. We also undertake a parametric study to investigate how varying reference temperatures will affect the exergoeconomic analysis of the GSHP system. A correlation between the ratio of thermodynamic loss rate ...

2007-03-15

15

Long-term storage of solar heat  

Energy Technology Data Exchange (ETDEWEB)

Stochastic models for the simulation of global radiation are discussed. Thermal transients in the ground are analyzed. The performance of buried-pipe storage and a space heating system with long-term storage is described.

1981-06-01

16

Heat pumps in urban space heating systems: Energy and environmental aspects  

International Nuclear Information System (INIS)

A statistical survey is conducted of air pollution in the city of Rome (Italy) due to conventional building space heating systems burning fossil fuels. The survey identifies the annual consumption of the different fuels and the relative amounts of the various pollutants released into the atmosphere by the heating plants, e.g., sulfur and nitrogen oxides, carbon monoxide, etc. Comparisons are then made between the ratios of urban heating plant air pollutants produced per tonne of fuel employed and those for ENEL (Italian National Electricity Board) coal, oil and natural gas fired power plants, in order to demonstrate the better environmental performances of the utility operated energy plants. The building space heating system energy consumption and pollution data are then used in a cost benefit analysis favouring the retrofitting of conventional ...

1991-01-01

17

The thermal response of an infinite line of open loop wells for ground coupled heat pump systems  

British Library Electronic Table of Contents (United Kingdom)

Ground thermal energy storage is a means of storing thermal energy underground during the summer and utilizing it during the winter. The main use of such a technology is in the heating, ventilating and air conditioning sector where the ground provides a stable temperature reservoir for a heat pump system. Heat pumps are mechanical systems that provide heating to a space in the winter, and cooling in the summer. They are increasingly popular because the same system provides both heating modes, depending on the direction of the cycle upon which they operate. The stable temperature reservoir allows the heat pump system to run at a higher efficiency. Thermal energy is transmitted to and from the ground by circulation of water through standing column geothermal wells. In commercial ...

2011-01-01

18

Recovering heat from the cupola stack  

Energy Technology Data Exchange (ETDEWEB)

A brief survey is given of some ways in which heat, which would normally be lost from a cupola furnace, is being recovered, either as hot water, steam, or electricity. Examples are provided of heat-recovery systems in Germany, Italy, and America. (author).

1986-01-01

19

Underground Mine Water Heating and Cooling Using Geothermal Heat Pump Systems  

Energy Technology Data Exchange (ETDEWEB)

In many regions of the world, flooded mines are a potentially cost-effective option for heating and cooling using geothermal heat pump systems. For example, a single coal seam in Pennsylvania, West Virginia, and Ohio contains 5.1 x 1012 L of water. The growing volume of water discharging from this one coal seam totals 380,000 L/min, which could theoretically heat and cool 20,000 homes. Using the water stored in the mines would conservatively extend this option to an order of magnitude more sites. Based on current energy prices, geothermal heat pump systems using mine water could reduce annual costs for heating by 67% and cooling by 50% over conventional methods (natural gas or heating oil and standard air conditioning).

2006-03-01

20

Geothermal heat pump applications: Industrial/commercial  

Energy Technology Data Exchange (ETDEWEB)

The fastest rate of growth in the space conditioning market has been attributed to the application of geothermal heat pumps to the industrial and commercial markets. The author reviews and provides examples of the three most popular components of a large geothermal heat pump system: geothermal earth coupling, heat pumps and heat exchangers, and building side terminals. These components are applied to three example geothermal installations: a library, an office building, and a school. Examples of energy use before and after the installation of a geothermal space conditioning system are summarized. General design and cost guidelines and comments on the use of geothermal heat pump in these and similar applications are discussed.

1999-07-01

21

Development of a solar thermal storage system suitable for the farmhouse heating in northeast China  

Energy Technology Data Exchange (ETDEWEB)

This study reported on the performance of a passive solar radiant floor heating system designed for standard energy-saving farmhouses in northeast China. Weather data in the region was analyzed in terms of solar radiation, temperature, humidity and light levels. The heating characteristics of the building materials such as windows, doors, walls and roofs were also analyzed along with the indoor thermal environment of the farmhouse. The heating load was then calculated along with the size of the thermal storage element and the area of the collector element. The passive solar radiant floor heating system was designed for heating during the winter and cooling in summer. According to the results, the heating characteristics of the system have the potential to improve farming villages environment and the ...

2010-07-01

22

Diffusion absorption heat pump. Diffusion-Absorptions-Waermepumpe  

Energy Technology Data Exchange (ETDEWEB)

The development of a gas-operated diffusion absorption heat pump for the heating of living spaces is described. By various improvement an energy efficiency of the prototypes of 1.5 was achieved. Structural alterations led to a lower overall height and lower production costs. The CFCs used in electric heat pumps were replaced by environmentally neutral ammonia. Compared with conventional gas heating systems, the CO2 output could be reduced by more than 30%. figs., tabs.

1992-02-01

23

Energy and exergy efficiencies of ground-source heat pump systems (GSHPs) for residential applications. Paper no. IGEC-1-067  

International Nuclear Information System (INIS)

Ground-source heat pump systems (GSHPSs), also referred to as geothermal heat pump systems (GHPSs), have been widely used in residential and commercial buildings for years due to their outstanding energy utilization efficiencies. In this study, an energy and exergy modeling of solar assisted ground-source heat pump systems for residential applications is presented for system analysis and performance evaluation. In this regard, the performance of a solar assisted ground-source heat pump heating system, installed in Solar Energy Institute of Ege University, Izmir, Turkey, is evaluated based on the actual operational data to show how energy and exergy efficiencies values change with the system. The average heating coefficient of performances ...

2005-06-12

24

A new method of heat transfer augmentation by means of foreign gas jet impingement in liquid bath  

International Nuclear Information System (INIS)

The authors discuss a two-phase two-component experimental system developed to study enhancement of heat transfer from a vertical chip size heater to surrounding liquid (Freon 113 or Ethanol) due to air jet impingement. Heat transfer coefficient was measured as function of jet velocity, heat flux and the distance between exit of jet tube and heated surface. The injector was placed very close to the hot surface. It was found that the heat transfer was notably enhanced with foreign gas impingement, especially in the cases of small temperature differences between wall and coolant. In fact for higher jet velocities the heat transfer coefficients tended to infinite while the temperature differences between wall and coolant were zero. The heat transfer coefficients decreased with the increasing of heat ...

1985-10-01

25

MINERGIE modules: heat pump - heat pump/solar - wood - wood/solar; Minergie-Module Waermepumpe - Waermepumpe/Solar - Holz - Holz/Solar  

Energy Technology Data Exchange (ETDEWEB)

This research report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that examined the feasibility of setting up 'MINERGIE' low-energy-consumption module standards for the production of heat in small residential buildings. The aims of the standards and the basic idea behind the MINERGIE-modules are discussed. The concepts of the modules for heat pumps and wood-fired heating systems and their combination with solar installations are examined, as are their areas of application. The requirements placed on the modules are listed. System concepts, including simple schematics for typical installations, are presented for wood-log, wood-chippings and pellets-fired systems as well as for ground-loop and air-water heat pump systems as well as their solar-aided counterparts. The ...

2005-07-01

26

Heat storage material  

Science.gov (United States)

The heat storage material consists of a mixture of oleic and stearic acids in which stearic acid is present to the extent of 30 percent to 90 percent by weight. In addition to this binary system, the invention is also directed to a ternary system in which diphenyl ether is present along with the stearic and oleic acids.

1955-12-06

27

Geothermal heat-pump systems are competing today against conventional fuels  

Energy Technology Data Exchange (ETDEWEB)

The alternative to the use of deeper wells through temperature amplification of the geothermal resource by electric heat pumps is explored. Systems in Ephrata, Washington and Chamberlain, South Dakota are explored. (MHR)

1982-12-01

28

Analysis and optimization of the heat transfer coefficient of a finned heat exchanger submitted to natural convection; Analise e otimizacao do coeficiente de transferencia de calor de um trocador aletado submetido a conveccao natural  

Energy Technology Data Exchange (ETDEWEB)

A heat transfer (condenser) of a domestic freezer was tested in a vertical channel in order to study the influence of the chimney effect in the optimization of the heat transfer coefficient. The variation of the opening of the channel, position and the heating power of the heat exchanger in the heat transfer coefficient was considered. The influence of the surface emissivity on the heat transfer by thermal radiation was studied with the heat exchanger testes without paint and with black paint. The air velocity entering the channel was measured with a hot wire anemometer. In order to evaluate the chimney effect, the heat exchanger was testes in a open ambient. This situation simulates its operational conditions when installed on the freezer system. The variables collected in the experimental ...

1997-07-01

29

Use of solar assisted geothermal heat pump and small wind turbine systems for heating agricultural and residential buildings  

Energy Technology Data Exchange (ETDEWEB)

The main objective of the present study is twofold: (i) to analyze thermal loads of the geothermally and passively heated solar greenhouses; and (ii) to investigate wind energy utilization in greenhouse heating which is modeled as a hybrid solar assisted geothermal heat pump and a small wind turbine system which is separately installed in the Solar Energy Institute of Ege University, Izmir, Turkey. The study shows 3.13% of the total yearly electricity energy consumption of the modeled system (3568 kWh) or 12.53% of the total yearly electricity energy consumptions of secondary water pumping, brine pumping, and fan coil (892 kWh) can be met by using small wind turbine system (SWTS) theoretically. According to this result, modeled passive solar pre heating technique and combined with geothermal heat pump ...

2010-01-15

30

Heating and cooling with geothermal energy: trends and accomplishments; Solutions de chauffage et de climatisation utilisant l`energie geothermique: tendances et realisations  

Energy Technology Data Exchange (ETDEWEB)

Recent developments in heat pump technology have made geothermal-based heat exchange systems particularly well-suited for the heating and cooling needs of buildings even in cold climates. The principles of geothermally-coupled heat pump heating and cooling systems were presented. Results of an in-situ study conducted by Hydro-Quebec on the efficiency of the geothermal heat pump system installed at the Saint-Hyacinthe professional school were summarized. This investigation was meant to be a case study of the applicability of these new technologies to the needs of the Quebec market. After the first year of service, the Saint-Hyacinthe system clearly demonstrated its cost effectiveness over conventional systems. It was predicted that geothermal ...

1996-03-01

31

Design and Operation of a Novel Capillary Pumped Two-Loop System for Cooling of Electronic Devices  

British Library Electronic Table of Contents (United Kingdom)

Heat pipes, loop heat pipes (LHP), and capillary pumped loops (CPL) have already proven their potential to remove high heat fluxes from a small electronic device and transport the heat to a heat sink that is large enough to transfer it into the ambient air. We introduce a novel two-loop system similar in design to CPLs but with an additional buoyancy-driven fluid loop. Non-degassed methanol is used as a working fluid. Key benefits compared to LHPs and CPLs are easy filling procedure, easy startup, and the tolerance toward noncondensable gases in the fluid. The amount of fluid in the system can be varied over a broad range without affecting the heat transfer performance. Three different inverted-meniscus-type evaporators have been employed in this study. A maximum evaporator heat transfer r...

2012-01-01

32

Residential vertical geothermal heat pump system models: Calibration to data  

Energy Technology Data Exchange (ETDEWEB)

A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was tuned to better match the measured data from the site. These tuned models were then interconnected to form the system model. The system model was then exercised in order to demonstrate its capabilities.

1997-12-31

33

Residential Vertical Geothermal Heat Pump System Models: Calibration to Data:  

Energy Technology Data Exchange (ETDEWEB)

A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was 'tuned' to better match the measured data from the site. These tuned models were then interconnect to form the system model. The system model was then exercised in order to demonatrate its capabilities.

1997-06-01

34

New crafts of a master builder  

Energy Technology Data Exchange (ETDEWEB)

Innovative new ideas for the construction of homes are described. A thermal energy storage system fireplace and a geothermal heat pump for homes are described.

1983-11-01

35

MASER"'\\ - NASA Technical Report Server (NTRS)  

Science.gov (United States)

cooling system designed to reject waste heat producedwithin the alternatorand. To other equipment operatingat much lower tempera- ...

36

Impingement-Film Heat Transfer Investigation.  

Science.gov (United States)

... Abstract : This report covers the investigation of an impingement-film cooling system designed to cool the exhaust ducts of turboshaft engines ...

1973-12-01

37

Comparison of central heating with district heating and small-scale cogeneration. Vergelijking van centrale verwarming met stadsverwarming en kleinschalige warmtekoppeling; Energiebesparing, emissies en financiele resultaten  

Energy Technology Data Exchange (ETDEWEB)

Three systems for the heat supply in the built environment have been compared for the costs, the energy consumption and emissions of CO{sub 2}, NO{sub x} and SO{sub 2}. The heating systems compared are based on central heating boilers, district heating systems in combination with combined steam and gas turbine cycles, and heating by means of several gas engines. From the results it appears that the boilers demand the lowest investments. The district heating systems are more expensive. Both heating systems, however, show considerable savings of energy (55 to 70%). The exploitation costs depend strongly on the fuel price scenarios used and the assumptions with regard to interest and inflation. The emissions of CO{sub 2} are also ...

1991-07-01

38

Heat transfer equipment design  

Energy Technology Data Exchange (ETDEWEB)

A comprehensive presentation is made of state-of-the-art configurations and design methodologies for heat transfer devices applicable to industrial processes, automotive systems, air conditioning/refrigeration, cryogenics, and petrochemicals refining. Attention is given to topics in heat exchanger mechanical design, single-phase convection processes, thermal design, two-phase exchanger thermal design, heat-transfer augmentation, and rheological effects. Computerized analysis and design methodologies are presented for the range of heat transfer systems, as well as advanced methods for optimization and performance projection.

1988-01-01

39

Heat rejection system  

Energy Technology Data Exchange (ETDEWEB)

A cooling system for rejecting waste heat consists of a cooling tower incorporating a plurality of coolant tubes provided with cooling fins and each having a plurality of cooling channels therein, means for directing a heat exchange fluid from the power plant through less than the total number of cooling channels to cool the heat exchange fluid under normal ambient temperature conditions, means for directing water through the remaining cooling channels whenever the ambient temperature rises above the temperature at which dry cooling of the heat exchange fluid is sufficient and means for cooling the water. 5 figs.

1980-01-22

40

Analysis of a bayonet tube heat exchanger  

Energy Technology Data Exchange (ETDEWEB)

This paper details the design, construction and testing of a bayonet tube heat exchanger for use in the process industry and potentially as part of an externally fired combined cycle. Detailed analysis of the system has been undertaken, in particular on the tube side. The data is reported in terms of temperature, pressure, heat gain and heat exchanger effectiveness, over a range of Reynolds numbers and shell side mixture ratios. Much of the heat gained by the tubes is in the annular flow of the bayonet tube. Overall the effectiveness of this system could exceed 70%. (Author)

2001-01-01

41

Study of solution for issues of an optimum operating plan in heat storing system; Chikunetsu system ni okeru saiteki un`yo keikaku mondai no kaiho ni taisuru ichikosatsu  

Energy Technology Data Exchange (ETDEWEB)

An approximate solution was proposed in which a sensitivity analysis by the storage and release of heat was performed for the subject issues and in which an operating method was thereby determined for the equipment constituting the system by means of a linear programming. Accordingly, a heat storage type energy supply system for a district cooling and heating was taken up as a concrete object to be examined. This system consisted of a gas turbine generator, initial power receiving equipment, gas boiler, electric heat pump for ice heat storage, cooling tower, heat exchanger, steam absorbing refrigerating machine, ice heat storage tank, cold and warm water heat storage tank, etc. As a result of comparison between the proposed method and the resolving method, ...

1996-02-01

42

In the Loop : A look at Manitoba's geothermal heat pump industry  

International Nuclear Information System (INIS)

This booklet outlines the position of Manitoba's heat pump market with the objective of promoting the widespread use of geothermal heat pumps in the province. It makes reference to the size of the market, customer satisfaction with heat pumps, and opinion of key players in the industry regarding the heat pump market. The information in this booklet is drawn on market research and lessons learned in Europe and the United States. In October 2001, a group of key stakeholders in Manitoba's heat pump market attended an industry working meeting to address the issues of market barriers, market enablers and market hot buttons. Market barriers include the high cost of geothermal heat pumps, lack of consumer awareness, lack of consistent standards, and public perception that heat pumps are not reliable. Market enablers include the low and stable ...

43

A unified model of combined energy systems with different cycle modes and its optimum performance characteristics  

Energy Technology Data Exchange (ETDEWEB)

A unified model is presented for a class of combined energy systems, in which the systems mainly consist of a heat engine, a combustor and a counter-flow heat exchanger and the heat engine in the systems may have different thermodynamic cycle modes such as the Brayton cycle, Carnot cycle, Stirling cycle, Ericsson cycle, and so on. Not only the irreversibilities of the heat leak and finite-rate heat transfer but also the different cycle modes of the heat engine are considered in the model. On the basis of Newton's law, expressions for the overall efficiency and power output of the combined energy system with an irreversible Brayton cycle are derived. The maximum overall efficiency and power output and other relevant parameters are calculated. The general characteristic ...

2009-06-15

44

Heating system maintenance over the telephone. Remote control and maintenance of heating systems; Die Heizung am Telefon. Fernueberwachung und Fernparametrierung von Heizungsanlagen  

Energy Technology Data Exchange (ETDEWEB)

The low budgets of local governments and Federal States in Germany as well as lack of financial means of renters delaying thorough modernisation of existing heating systems in residential and public buildings, novel heat supply and related customer services are emerging on the market. Heat supply companies and housing construction associations increasingly use modern electronics and telecommunication systems for heating system upgrading and reliable operation and maintenance. This option holds an enormous potential of saving money today and in the future. Installation of remote control and maintenance systems and the related telephone-based services offer fast repair and other services via electronic telecommunications systems, thus saving money and manpower for the repair services of ...

1997-11-01

45

Control of anodic passivation systems  

Energy Technology Data Exchange (ETDEWEB)

A method is described of controlling an anodic protection system in a heat exchanger comprising: (a) installing at least one cathode within the heat exchanger, at least one cathode being aligned with the longitudinal axis of the heat exchanger and extending substantially along the length of the heat exchanger; (b) installing a first reference electrode within and at one end of the heat exchanger, the first reference electrode having a first controller having a set point for control and a power supply having an output creating an electrical potential between at least one cathode and the heat exchanger; (c) measuring the electrical potential of the heat exchanger with the first reference electrode; (d) operating the first controller in response to measurements made by the first reference electrode to change the output of ...

1987-08-25

46

The feasibility of using a septic tank as a heat source for geothermal heat pumps  

Energy Technology Data Exchange (ETDEWEB)

A geothermal heat pump (GHP) system with three ground coils was installed in a residence in northern Idaho with a portion of the ground heat exchanger wrapped around the residential septic tank. The septic coil provided a significant portion of the heating for the residence over the heating season. There was no evidence of the septic tank freezing up or failing to properly function. Utilizing a septic tank as a heat source for GHP systems is feasible design option if the septic tank is used on a full-time basis. However, the tank should be surrounded on all sides by a large amount of soil and/or insulated from the ground surface to ensure that ground temperatures near the tank remain warm during the winter.

1999-11-01

47

Study on the application of a geothermal heat pump; Etude sur l`application d`une pompe a chaleur geothermique  

Energy Technology Data Exchange (ETDEWEB)

The heating system of the `Centre integre de mecanique industrielle de la Chaudiere`, in Saint-Georges, Quebec, is based on a solar wall and a geothermal heat pump with a glycol/water mixture circulating in 44 wells that are 100 m deep. With installation costs below $25 per sq.m, more than 85 per cent of the heating needs of the 9500 sq.m centre were supplied by geothermal power. The geothermal heat pump is composed of a well field and two 211-kW cooling units, each equipped with four coiled compressors. In winter, heat is pumped from the earth and in summer, a heat exchanger with control valves allows to heat to be dumped back into the earth. The monitoring and simulation of the system proved its efficiency, considering the climatic conditions in Quebec. The annual consumption of geothermal ...

1996-12-01

48

Geothermal heat pumps - gaining ground in the UK and worldwide  

Energy Technology Data Exchange (ETDEWEB)

This 2001 edition of the guide to UK renewable energy companies examines the geothermal heat pump sector, and discusses the technology involved, installations of geothermal heat pumps, the activity in the UK market with increased interest in UK geothermal heat pump products from abroad, and developments in the building sector. The UK government's increased support for the industry including its sponsorship of the Affordable Warmth programme, and the future potential of ground source systems are discussed.

2001-07-01

49

Geothermal heat pumps - gaining ground in the UK and worldwide  

International Nuclear Information System (INIS)

This 2001 edition of the guide to UK renewable energy companies examines the geothermal heat pump sector, and discusses the technology involved, installations of geothermal heat pumps, the activity in the UK market with increased interest in UK geothermal heat pump products from abroad, and developments in the building sector. The UK government's increased support for the industry including its sponsorship of the Affordable Warmth programme, and the future potential of ground source systems are discussed.

50

Radiant heating and cooling, displacement ventilation with heat recovery and storm water cooling: An environmentally responsible HVAC system  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the design, operation, and performance of an HVAC system installed as part of a project to demonstrate energy efficiency and environmental responsibility in commercial buildings. The systems installed in the 2180 m{sup 2} office building provide superior air quality and thermal comfort while requiring only half the electrical energy of conventional systems primarily because of the hydronic heating and cooling system. Gas use for the building is higher than expected because of longer operating hours and poor performance of the boiler/absorption chiller.

1998-12-31

51

Thermal energy storage system with stearic acid as phase change material  

Energy Technology Data Exchange (ETDEWEB)

A simple tube-in-tube heat exchanger system for thermal energy storage employing stearic acid as PCM has been investigated. The performance and heat transfer characteristics of such a system were studied. Phase transition temperature range and times were measured and the speed of the phase transition front was computed. The melting front was found to move in the radial direction inward as well as in the axial direction from the top toward the bottom of the phase change material PCM tube. The speed of the melting front is enhanced by a convection heat transfer mechanism in the melted PCM. The heat transfer rate and, consequently, phase transition time can be altered by changing the water inlet temperature to the heat exchanger. In addition, a faster phase transition is realized by placing the heat exchanger in a ...

1994-10-01

52

Numerical heat transfer studies of the fatty acids for different heat exchanger materials on the performance of a latent heat storage system  

Energy Technology Data Exchange (ETDEWEB)

Theoretical investigations of fatty acids as a phase change material (PCM) for energy storage system have been conducted in this study. The selected fatty acids were capric acid, lauric acid, myristic acid, palmitic acid and stearic acid. For the two-dimensional simulation model based on the enthalpy approach, calculations have been made for the melt fraction with conduction only. Glass, stainless steel, tin, aluminium mixed, aluminium and copper were used as heat exchanger materials in the numerical calculations. Theoretical results show that capric acid was found good compatibility with latent heat storage system. The large value of thermal conductivity of heat exchanger materials did not make significant contribution on the melt fraction. (author)

2005-11-01

53

Rural residential application of geothermal heat pump. Final grant report  

Energy Technology Data Exchange (ETDEWEB)

A project to demonstrate residential heating and cooling with a well-water source heat pump is documented. The system is schematically illustrated and described, and project experience is discussed. The system is capable of using source water as cool as 40/sup 0/F. Project expenses are accounted for. (LEW)

1982-07-30

54

Concept of Plasma Spraying System for Solid Oxide Fuel Cell: Heating Studies of YSZ Particle in Plasma Jet  

International Nuclear Information System (INIS)

One of several methods to build YSZ electrolyte of SOFC is plasma spraying. This system heats particle to a melting point and then pushing them into target and forming a deposition. This paper presents heating studies of YSZ particle in plasma jet. By simple model it is shown that the required time such those YSZ particle with grain size of 50 ?m to be melt is around 12 x 10-4 second. (author)

2006-07-01

55

Influence of pollution abatement measures on the evaluation of air pollution caused by heating systems with special regard to the costs involved. Einfluss von emissionsmindernden Massnahmen auf die Schadstoffbewertung der Heizsysteme unter Beruecksichtigung der damit verbundenen Kosten  

Energy Technology Data Exchange (ETDEWEB)

Apart from presenting the marginal legal conditions the research program contains a brief description of current pollution abatement measures, representative heating systems and individually suitable pollution abatement technologies and an account of the determination of the concentration of major pollutants. The comparative evaluation of heating systems assesses their environmental effects, i.e. air pollution caused by heating systems. The determination of the costs of available heat is followed by an overall evaluation of the results obtained with special regard to the costs involved by pollution abatement measures.

1986-01-01

56

Energy concepts and the environment  

Energy Technology Data Exchange (ETDEWEB)

The paper discusses a number of recent studies investigating into the energy conservation and environmental impacts of electric heating systems (off-peak storage systems). In future, i.e. in and after 1993, off-peak storage systems will be evaluated through comparative analyses of oil-fired heating systems, pollutant emission analyses, the eventual success of pollution abatement measures designed for power plant emissions to keep within the legal limiting values, and the possible abandonment of pollution abatement measures abroad. Opposing the electric heating studies submitted by the electric power industry the author refutes their favourable results referring to the palliative selection of inadequate or vague parameters. Assuming average power plant pollutant emissions of 180 mg/standard/sup 3/ the nitrogen oxide emissions of oil-fired ...

1988-03-01

57

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

International Nuclear Information System (INIS)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-22

58

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

Energy Technology Data Exchange (ETDEWEB)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-01

59

Non-polluting cogeneration  

Energy Technology Data Exchange (ETDEWEB)

HEW is operating one of the biggest district heating networks of the Federal Republic of Germany. The paper discusses a number of projects which in recent years have been engaged in extensive air pollution abatement measures to make district heating an environmentally compatible energy source. Emphasis is placed on the hot gas cleanup system of block 2 of the harbor power plant. The system is the first of its kind to have realized an SCR system connected with the desulfurization system for industrial denitrification purposes.

1988-01-01

60

Competition advantage by utilizing the gross calorific value-high potential for the local heat supply; Wettbewerbsvorsprung durch Brennwertnutzung. Hohes Potential bei der Nahwaermeversorgung  

Energy Technology Data Exchange (ETDEWEB)

The gross calorific value (H{sub o}) is the amount of heat which is generated by total combustion of a type of fuel. It also includes that part of heat which is generated by steam from evaporated water contained in heating gas. In conventional heating boilers, this heat portion is not being utilized at all. To utilize the gross calorific value, it is necessary to extract from the exhaust gas the evaporation heat bound in steam and to return this to the heating system. This means that the exhaust gas has to be chilled by the return water of the heating system and condensed in suitable heat exchangers to well below the dew point. (orig.) [Deutsch] Waermelieferanten im Bereich der Nahwaermeversorgung koennen durch die Anwendung verfuegbarer und bewaehrter ...

1999-01-01

61

Comparative performance of two types of evacuated tube solar collectors in a residential heating and cooling system. The progress report  

Science.gov (United States)

Two types of evacuated tube solar collectors have been operated in space heating, cooling and domestic hot water heating systems in Colorado State University Solar House I. An experimental collector from Corning Glass Works supplied heat to the system from January 1977 through February 1978, and an experimental collector from Philips Research Laboratory, Aachen, which is currently in use, has been operating since August 1978. A flat absorber plate inside a single-walled glass tube is used in the Corning design, whereas heat is conducted through a single glass wall to an external heat exchanger plate in the Philips collector. In comparison with conventional flat-plate collectors, both types show reduced heat losses and improved efficiency. For space heating and hot water supply in winter, the solar ...

1979-01-01

62

Fiscal 2000 project of inviting proposals for international joint research - invitation for international proposal (Energy conservation No.2). Achievement report on international joint study on popularization promotion of geothermal heat pump-assisted environmentally compatible heating system for Changchun City, China; 2000 nendo kokusai kyodo kenkyu teian kobo jigyo - kokusai teian kobo (Shoe No.2). Chinetsu heat pump ni yoru Chugoku Changchun shi kankyo tekigogata danbo system no fukyu sokushin ni kansuru kokusai kyodo kenkyu seika hokokusho  

Energy Technology Data Exchange (ETDEWEB)

A geothermal heat pump-assisted heating system is introduced into Changchun City and a survey is conducted to determine if the system may be popularized in this extremely cold region located in the northeastern part of China. In concrete terms, the hot water that circulates through the office building of Changchun Ground Heat Development Co., Ltd., is switched to hot water prepared by a geothermal heat pump. The test continued from December 2000 to March 2001. It is then concluded that heating by geothermal heat pumps will be fully serviceable to Changchun City. Implemented are (1) the shift from the coal fired boiler system to a geothermal heat pump system comprising 16 subterranean heat exchangers for the heating of ...

2001-03-01

63

Field performance of a premium heating oil  

Energy Technology Data Exchange (ETDEWEB)

As part of our ongoing research to provide quality improvements to heating oil, Mobil Oil together with Santa Fuel, Inc., conducted a field trial to investigate the performance of a new premium heating oil. This premium heating oil contains an additive system designed to minimize sludge related problems in the fuel delivery system of residential home heating systems. The additive used was similar to others reported at this and earlier BNL conferences, but was further developed to enhance its performance in oil heat systems. The premium heating oil was bulk additized and delivered to a subset of the customer base. Fuel related, unscheduled service calls were monitored in this test area, as well as in a similar baseline area that did not receive the premium ...

1996-07-01

64

Performance characteristics of a natural circulation cooling/latent heat storage system  

Energy Technology Data Exchange (ETDEWEB)

A cooling system was developed which could be used even in such areas where the maximum and minimum temperatures of a day might differ widely. The system features in that a latent heat storage unit is connected to the natural circulation cooling unit consisting of 2 heat exchangers where condensed gas (refrigerant) which performs gas-liquid change has been sealed, enabling to cool objects night and day without the requirement for any power source. Electronic equipment was installed in an insulated shelter. Lauric acid and refrigerant R-22 were used as the latent heat storage medium and the heat transport medium respectively. Natural convection heat transfer performance of the outside surfaces of the condenser and the evaporator and the transient behavior of the system during the melting and solidification periods of the ...

1987-09-25

65

Guidelines on exchangers  

Energy Technology Data Exchange (ETDEWEB)

Experience has shown that a list of tips provides designers and engineers with an effective guide in their areas of duties and concern. This list contains new and rare information on heat exchangers and heat recovery systems. The information presented can be used effectively with personal computers and pocket calculators and also conveniently translated into computer programs and nomographs.

1985-08-01

66

Load calculation and system evaluation for electric vehicle climate control  

Energy Technology Data Exchange (ETDEWEB)

This paper presents an analysis of the applicability of alternative systems for electric vehicle (EV) heating and air conditioning (HVAC). The paper consists of two parts. The first part is a cooling and heating load calculation for electric vehicles. The second part is an evaluation of several systems that can provide the desired cooling and heating in EVs. These systems are ranked according to their overall weight The overall weight is calculated by adding the system weight and the weight of the battery necessary to provide energy for system operation. The system with the minimum overall weight is considered to be the best, because minimum vehicle weight decreases the energy required for propulsion, and therefore increases the vehicle range. Three systems are considered as the ...

1994-09-12

67

Heating and cooling  

Energy Technology Data Exchange (ETDEWEB)

Why pay for energy when there`s a free stockpile of it right under your feet? With the help of a geothermal heat pump system, one can extract that energy from the ground and put it to good use, lowering heating and cooling costs. From private homes to public schools and fast-food restaurants, an increasing number of establishments are turning to geothermal heat pump systems for space conditioning. Experts say 1998 is already proving to be the best year yet for the technology, and they foresee an even more promising future. Some examples of geothermal energy use are given.

1998-05-01

68

Flooded Underground Coal Mines: A Significant Source of Inexpensive Geothermal Energy  

Energy Technology Data Exchange (ETDEWEB)

Many mining regions in the United States contain extensive areas of flooded underground mines. The water within these mines represents a significant and widespread opportunity for extracting low-grade, geothermal energy. Based on current energy prices, geothermal heat pump systems using mine water could reduce the annual costs for heating to over 70 percent compared to conventional heating methods (natural gas or heating oil). These same systems could reduce annual cooling costs by up to 50 percent over standard air conditioning in many areas of the country. (Formatted full-text version is released by permission of publisher)

2007-04-01

69

Thermal gradient humidification-dehumidification desalination system  

Energy Technology Data Exchange (ETDEWEB)

A solar energy desalination process utilizing solar radiation directly for the evaporation of salt water is described. Ambient air takes on water vapor as the air passes through an evaporative medium. It is then directed between a saline water-covered, solar absorbing surface and a solar collecting housing. The resulting heated and moisture-saturated air is cooled in a heat exchange means where condensation of fresh water occurs. Simultaneously, cool salt water is utilized as the cooling water in the heat exchange means, and takes on the heat of condensation given up by the condensing vapor. The heated salt water from the heat exchange means is partially directed over the solar absorbing surface, and at least a portion of it is also directed to wet the evaporative medium. Several optional sub-processes are described for operation of the ...

1982-12-14

70

Horizontal ground coupled heat pump: Thermal-economic modeling and optimization  

Energy Technology Data Exchange (ETDEWEB)

The modeling and optimizing processes of a Ground Coupled Heat Pump (GCHP) with closed Horizontal Ground Heat eXchanger (HGHX) are presented in this paper. After thermal modeling of GCHP including HGHX, the optimum design parameters of the system were estimated by minimizing a defined objective function (total of investment and operation costs) subject to a list of constraints. This procedure was performed applying Genetic Algorithm technique. For given heating/cooling loads and various climatic conditions, the optimum values of saturated temperature/pressure of condenser and evaporator as well as inlet and outlet temperatures of the water source in cooling and heating modes were predicted. Then, for our case study, the design parameters as well as the configuration of HGHX were obtained. Furthermore, the sensitivity analysis of change in the total annual cost of the ...

2010-12-15

71

Full-scale model of cooling and heating system for JT-60 vacuum vessel  

Science.gov (United States)

A full-scale model of a rigid sectorial ring and a set of bellows which was covered with a temperature control layer and a coolant supply equipment was constructed to verify the adequacy of the heating and cooling system designed for JT-60. To cool and heat it effectively and to decrease the temperature differences among the various parts in the vacuum vessel, heater units and cooling pipes were located on the surface of the ring. The temperature control layer is to heat the vessel to 500/degree/sub //C within 70 hours and to maintain it at the temperature for 48 hours for simulating the state of bakeout. Subsequently the vessel is cooled down within about the same time as in heating. Prior to the series of tests, numerical analyses were performed to predict the cooling and heating efficiencies on the model and to examine the method of the temperature ...

1981-01-01

72

Basic study on heat transfer characteristics of liquid Na in a decay-heat removal system of LMFBR  

Energy Technology Data Exchange (ETDEWEB)

A numerical analysis is performed to clarify the heat transfer characteristics of combined convection around the tubes which form a single row perpendicularly arranged to a forced flow in the direction of gravity. A boundary-fitted coordinate transformation technique is adopted to solve the governing equations numerically. It is found in the case of liquid sodium that gravity-induced flow gives no substantial effect to heat transfer augmentation in a low Reynolds number region while it can be sufficiently expected in the ordinary fluids in the same Reynolds number region. This means that such heat transfer augmentation as expected in ordinary fluids can not be realized when crossflow-type heat exchangers installed for decay-heat removal operates in a low Reynolds number region.

1988-02-01

73

A basic study on heat transfer characteristics of liquid Na in a decay-heat removal system of LMFBR  

International Nuclear Information System (INIS)

A numerical analysis is performed to clarify the heat transfer characteristics of combined convection around the tubes which form a single row perpendicularly arranged to a forced flow in the direction of gravity. A boundary-fitted coordinate transformation technique is adopted to solve the governing equations numerically. It is found in the case of liquid sodium that gravity-induced flow gives no substantial effect to heat transfer augmentation in a low Reynolds number region while it can be sufficiently expected in the ordinary fluids in the same Reynolds number region. This means that such heat transfer augmentation as expected in ordinary fluids can not be realized when crossflow-type heat exchangers installed for decay-heat removal operates in a low Reynolds number region. (author).

1988-01-01

74

Canadian R&D on oil-fired combustion systems  

Energy Technology Data Exchange (ETDEWEB)

This paper describes research and development presently being conducted on oil-fired space and tap water heating systems by the Advanced Combustion Technology Group, CCRL/ERL/CANMET, in Ottawa, Canada. The presentation will focus on R&D activities at CCRL in support of the Canadian Oil Heat Association (COHA) and of the energy policy initiatives of Natural Resources Canada. Progress will be reported on activities to develop suitable oil-fired integrated systems to satisfy the low energy demands of new homes. The utilization of fuzzy logic-based control heating systems including fan coils for a complete range of old and new North American housing will be discussed. Additional activities to be discussed in the presentation will relate to the development of appropriate seasonal efficiency standards for complex integrated space/water heating ...

1996-07-01

75

Performance analysis on a hybrid air-conditioning system of a green building  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the performance analysis on a hybrid air-conditioning system according to the hybrid building energy system of the green building demonstration project in Shanghai, in which a 150 m{sup 2} solar collector is used to power two 10 kW adsorption chillers, a vapor compression heat pump is used to cool air in the evaporating end while the condensing heating at about 80{sup o}C is fully used to regenerate a liquid desiccant dehumidification system. In the hybrid system, the sensible cooling to the air is treated mainly by solar adsorption cooling and vapor compression cooling, whereas the latent heat is treated by the liquid desiccant dehumidification system with regeneration from the condensing heat of the heat pump. The results show that the performance of this ...

2006-05-15

76

Design and performance of the solar-powered floor heating system in a green building  

Energy Technology Data Exchange (ETDEWEB)

In the green building of Shanghai Research Institute of Building Science, the evacuated tubular solar collectors with a total area of 150 m{sup 2} were installed to provide heating for the covered area of 460 m{sup 2}. The floor heating coil pipes were made of high-quality pure copper with the dimension of {phi} 12 x 0.7 mm. Under typical weather condition of Shanghai, the average heating capacity was 25.04 kW during the working hours from 9:00 to 17:00, which was sufficient to keep indoor thermal environment. The average electric COP of the floor heating system was 19.76 during the system operation. Compared with the widely used air-source heat pump heating systems with the electric COP of 3.5 in Shanghai, the solar-powered floor heating system shows great ...

2009-07-15

77

Core Heat Transfer Model Validation of the TASS/SMR-S Code using the Bennett's Test  

International Nuclear Information System (INIS)

The SMART (System-integrated Modular Advanced ReacTor) which is a 330 MWt advanced integral PWR was developed by the KAERI (Korea Atomic Energy Institute) for electricity generation and seawater desalination. A thermal hydraulic evaluation and analysis of the SMART is performed by the TASS /SMR-S (Transient And Setpoint Simulation/System integrated Modular Reactor-Safety). The TASS/SMR-S code has various models reflecting the design features of the SMART such as the drift flux model, the core models (core power and core heat transfer model), the component models, and the specific models. One of the core models is the core heat transfer model. The role of this model is to calculate the heat flux and radial temperature profiles at a fuel rod surface using the relevant heat transfer correlations for all of the heat transfer modes. Also it is ...

2010-10-01

78

Kelvin-day function for climatic solar heating design  

Energy Technology Data Exchange (ETDEWEB)

A method of Kelvin-day function for climatic solar heating design is presented. The long term temperature distribution is used to find the solar fraction for building heating. A solar heating system is considered to provide heat needed up to an auxiliary heater cut-in temperature which is determined by both heat gain of solar heating system and overall heat loss coefficient of the building. The amount of auxiliary heat needed is calculated from a Kelvin-day value at this cut-in temperature. The cut-in temperature will change from different solar heating system designs, and the Kelvin-day value at this cut-in temperature will be varied. By using the numerical curve-fitting method, the Kelvin-day value at any temperature base can be ...

1981-01-01

79

A desiccant dehumidifier for electric vehicle heating  

Energy Technology Data Exchange (ETDEWEB)

Vehicle heating requires a substantial amount of energy. Engines in conventional cars produce enough waste heat to provide comfort heating and defogging/defrosting, even under very extreme conditions. Electric vehicles (EVs), however, generate little waste heat. Using battery energy for heating may consume a substantial fraction of the energy storage capacity, reducing the vehicle range, which is one of the most important parameters in determining EV acceptability. Water vapor generated by the vehicle passengers is in large part responsible for the high heating loads existing in vehicles. In cold climates, the generation of water vapor inside the car may result in water condensation on the windows, diminishing visibility. Two strategies are commonly used to avoid condensation on windows: windows are kept warm, and a large amount of ambient air is introduced in ...

1996-09-01

80

Fuel Cell Power Model Elucidates Life-Cycle Costs for Fuel Cell-Based Combined Heat, Hydrogen, and Power (CHHP) Production Systems (Fact Sheet)  

Energy Technology Data Exchange (ETDEWEB)

This fact sheet describes NREL's accomplishments in accurately modeling costs for fuel cell-based combined heat, hydrogen, and power systems. Work was performed by NREL's Hydrogen Technologies and Systems Center.

2010-11-01

81

Field performance of an energy pile system for space heating  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the field performance of air conditioning with an energy pile system, which was applied to the pile foundations of an actual building for the purpose of reducing the cost of the underground heat exchanger. First, the building for both office and residential use, for which a space heating and cooling system using friction piles was installed, was built in Sapporo in December 2000. Second, three tests were carried out to specify the design of a heat exchanger inside the pile, and a U-tube type underground heat exchanger was adopted from the viewpoint of energy efficiency and installation costs. Long-term space heating operation measurements indicated that the seasonal average temperatures of brine returning from the underground and pile surfaces were 2.4 and 6.7 deg C, respectively. The average coefficient of performance ...

2007-05-15

82

Thermophotovoltaics. Basic principles and critical aspects of system design  

Energy Technology Data Exchange (ETDEWEB)

Thermophotovoltaics is the science and technology associated with the direct generation of electricity from high temperature heat. Potential applications include combined heat and power, portable and auxiliary power, radioisotope space power, industrial waste heat recovery and concentrated solar power. This book aims at serving as an introduction to the underlying theory, overview of present day components and system arrangements, and update of the latest developments in the field. The emphasis is placed on the understanding of the critical aspects of efficient thermophotovoltaic system design. The aim is to assist researchers in the field. (orig.)

2011-07-01

83

Review of Cardiff telephone exchange total energy system after three years operation  

Energy Technology Data Exchange (ETDEWEB)

A self contained continuous power generation system as described at INTELEC 1979, was successfully commissioned and put into service in a major communications centre at Cardiff in Wales. The objective was to provide all telecommunications equipment and electrical building engineering services from a dual fuel enginegenerating plant, and to recover waste heat energy to heat or cool the building. The plant, which is fully automatic, comprises five 1300kW engines using natural gas or diesel oil, and associated waste heat boiler and chiller systems. This paper reviews the functioning of the plant during its first three years of operation.

1983-10-01

84

Heating-cooling ceilings and cold beams; Plafonds chauffants-rafraichissants et poutres froides  

Energy Technology Data Exchange (ETDEWEB)

The aim of this document is to make a state-of-the-art of the techniques of heating-cooling ceilings and cold beams. These systems offer many advantages: they generate a high quality thermal comfort, they are energy efficient, and offer important room saving, particularly interesting in the case of building renovation. The document comprises 5 parts dealing with: 1 - the heating-cooling ceilings; 2 - the cold beams; 3 - the elements necessary for the dimensioning (building-system interactions, ventilation, temperature regulation and safety systems); 4 - dimensioning method; 5 - design, realization and operation: the rules to follow. (J.S.)

2004-07-01

85

Safety considerations of active process water system shutdown for TAPP - 3 and 4  

International Nuclear Information System (INIS)

Active Process Water (APW) System, provided as unitized closed loop system in Tarapur Atomic Power Project Units-3 and 4, serves to remove heat from various heat exchangers. One of the important loads served by APW system is shutdown cooling heat exchangers and if APW shutdown is taken then reactor cannot be maintained in cold shutdown condition. It is estimated that after 7 days of reactor shutdown, if about 20% of the normal cooling flow to shutdown cooling heat exchangers is provided then along with keeping PHT in cold shutdown state, reactor components, moderator, end shield water, calandria vault water and calandria vault concrete temperature can be maintained within technical specification limits for extended duration. (author)

2005-12-01

86

Pipe Freeze Prevention for Passive Solar Water Heaters Using a Room-Air Natural Convection Loop: Preprint  

Energy Technology Data Exchange (ETDEWEB)

Conference paper regarding research in the use of freeze prevention for passive solar domestic water heating systems.

2006-05-01

87

Integral air-conditioning system for electric cars. Integrales Klimasystem fuer Elektroautomobile  

Energy Technology Data Exchange (ETDEWEB)

Increasing environmental awareness and new legislation in Europe and, in particular, America have accelerated the development of marketable electric cars which satisfy customer demands in terms of performance, range capability, safety and comfort. Tomorrow's electric cars will therefore require powerful heating and cooling systems for the passenger compartment which meet the conditions specific to this particular mode of transport and which do not overly affect the range capability of such vehicles. At Behr GmbH suitable system concepts were developed at a very early stage which were based on a high proportion of recirculated air, the use of the A/C unit as a heat pump, and heat recovery. This paper will examine two typical A/C systems which combine good heating and cooling characteristics with the low electric power requirement of ...

1992-11-01

88

Evaluation of Two Microclimate Cooling Air Vests on a Heated ...  

Science.gov (United States)

... If the MCAV is used in conjunction with a cooling system designed for the CVC air vest, the wearer would receive more cooling due entirely to the ...

1992-12-01

89

Boiling flow instabilities in parallel channels with enhanced heat transfer  

International Nuclear Information System (INIS)

During the last two decades, the demand for higher heat transfers in the heat exchangers has kept increasing. These high heat transfer rates can be obtained by using two-phase flows, or heat transfer augmented surfaces, or in some cases, both. Thus, the boiling flows and the associated two-phase flow instabilities have been studied by many investigators. Most of the work in boiling flows has been concentrated on single channel upflow systems or on parallel channel systems with plain heat transfer surfaces. The boiling flow instabilities in multi-channel systems should be covered to a greater extent, studying the effects of various parameters, such as inlet and outlet restriction, mass flow rates, the property variations, heat transfer coefficients, equal and unequal heat inputs ...

1985-10-01

90

FY1998 research report on the basic research on geothermal district heating in Kamchatka, Russia; 1998 nendo Roshia Renpo Kamchatka shu ni okeru chinetsu riyo ni yoru chiiki danbo ni kansuru kiso chosa hokokusho  

Energy Technology Data Exchange (ETDEWEB)

Petropavlovsk-Kamchatky (P-K) city in Kamchatka, Russia is operating hot-water district heating using heavy oil boilers and waste hot water of thermal power plants as heat sources. Feasibility study was made on district heating using natural geothermal hot water and/or geothermal heat pump systems as heat sources of hot water supply for reduction of greenhouse effect gas emission. Among 3 areas including geothermal hot water, use of hot water in K area was impossible because of lower temperature and less spring water. Use of hot water in P and UP areas was impossible as primary hot water because of temperature drop to 64 degrees C during hot water supply toward P-K city. The building heating operation test was carried out using the geothermal heat pump system installed in a newly drilled ...

1999-05-01

91

Proceedings of the 1991 ASME JSME thermal engineering joint conference  

International Nuclear Information System (INIS)

This book is organized under the following headings: Electrohydrodynamic heat transfer augmentation; Forced convection augmentation and heat transfer control; Turbulent heat transfer; Thermal problems in the environment; Energy conversion systems; Measurement, visualization, and imaging; Thermal problems in space technology; and Thermal properties.

1991-03-17

92

Heat transfer from magneto-rheological fluid dampers  

Science.gov (United States)

This paper presents a theoretical study of heat transfer from magneto-rheological fluid (MRF) dampers. A lumped system model is developed which is capable of predicting the temperature rise for any size MRF damper. As a case study example, finned and unfinned dampers are compared for automotive-size MRF dampers. The results demonstrate that heat transfer from these devices can be enhanced considerably with the use of fins.

2000-04-01

93

Combined gas/steam turbine process. Kombinierter Gas/Dampfturbinen-Prozess  

Energy Technology Data Exchange (ETDEWEB)

A combined gas/steam turbine process includes a high-pressure furnace and a high pressure gasification unit with a mounted upstream of a combustion chamber there is a gas turbine with a waste heat system. Combustion heat which is not needed to heat the flue gas to combustion temperature is released from the furnace and transferred to ths combustion air going into the combustion chamber.

1991-01-31

94

Final report for the DOE Suede Project, (solar utilization/economic development and employment project)  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this solar energy project was to design, manufacture, install, maintain and evaluate solar heating systems in order to stimulate community acceptance of the practicality of solar applications, reduce non-renewable energy resource consumption, and decrease residential expenditures for energy. The project also provided skill training and experience for CETA employees in the design, manufacture, and installation of solar energy equipment systems. CDC's contract had four separate solar energy projects; namely: Domestic Water Heating Systems for four Single-Family Homes; Domestic Water Heating for an industrial building; Domestic Water Heating for a (4) unit apartment complex (includes (12) supplemental space heating units); and Integral Passive Water Heaters and Energy Conservation Devices for (8) one ...

1983-10-19

95

Overview of US LMFBR Structural Materials Mechanical Properties Program  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the objective, scope, and status of the US Department of Energy's Materials and Structures Program to develop a data base on mechanical properties of structural materials for out-of-core structures and components for LMFBRs. Information on the development of a reference data base on materials for the reactor system, reactor enclosure system, primary heat transport system, intermediate heat transport system, and steam generator system is included. In addition, the development of the data and analyses to account for the effects of temperature and stress, as well as water/steam, sodium, and radiation environments, is described. Plans for the development of alternative materials for future out-of-core applications are presented.

1983-01-01

96

Overview of U.S. LMFBR structural materials mechanical properties program  

International Nuclear Information System (INIS)

This paper presents the objective, scope, and status of the U.S. Department of Energy's Materials and Structures Program to develop a data base on mechanical properties of structural materials for out-of-core structures and components for LMFBRs. Information on the development of a reference data base on materials for the reactor system, reactor enclosure system, primary heat transport system, intermediate heat transport system, and steam generator system is included. In addition, the development of the data and analyses to account for the effects of temperature and stress, as well as water/steam, sodium, and radiation environments, is described. Plans for the development of alternative materials for future out-of-core applications are presented. (author).

1983-10-10

97

Oil/electric hybrid heating experiment and demonstration. [Executive summary is a separate volume  

Energy Technology Data Exchange (ETDEWEB)

Oil/electric heating systems and energy measuring instrumentation were installed in 50 houses in Deep River, Ontario. These were operated and monitored for two heating seasons to demonstrate their performance and determine the percentage oil placement as a function of heater capacity and control system. All experimental data was stored and processed by computer. It was found that oil furnace utilization efficiency varied from 48 to 59% for an average of 53.5%. Oil displacement ranged from 49 to 83% for 2.5 and 5.0 kW electric heaters controlled by two-stage indoor thermostats. Fuel costs for oil/electric hybrid heating, with 5.0 kW plenum heaters and indoor two-stage thermostats, were 20% less than for oil heating, based on average furnace efficency and 1983 January retail fuel prices. Annual load factors above 37% were achieved for plenum heaters compared to ...

1983-07-01

98

Heat loss from an open cavity  

Energy Technology Data Exchange (ETDEWEB)

Cavity type receivers are used extensively in concentrating solar thermal energy collecting systems. The Solar Total Energy Project (STEP) in Shenandoah, Georgia is a large scale field test for the collection of solar thermal energy. The STEP experiment consists of a large field array of solar collectors used to supplement the process steam, cooling and other electrical power requirements of an adjacent knitwear manufacturing facility. The purpose of the tests, conducted for this study, was to isolate and quantify the radiative, conductive, and convective components of total heat loss, and to determine the effects of operating temperature, receiver angle, and aperture size on cavity heat loss. An analytical model for radiative heat loss was developed and compared with two other methods used to determine radiative heat loss. A proposed convective heat loss ...

1995-12-01

99

Condensation heat transfer in a steam-water stratified flow  

Energy Technology Data Exchange (ETDEWEB)

Fundamental phenomena of condensation heat transfer at a steam-water interface have been studied related to the thermo-hydrodynamics of the emergency core cooling system for light water reactors. In this study temperature fluctuations near the interface and in the liquid phase were measured using fine thermocouples for a saturated steam-subcooled water co-current stratified two-phase flow in a nearly horizontal rectangular channel, and heat transfer coefficients were determined experimentally. The values of the condensation heat transfer coefficients in this experiment are from 6 to 40 kW/m{sup 2}K. In the regions of high Reynolds numbers, as the steam Reynolds numbers become larger, the average interfacial heat transfer coefficients tend to increase. The corelations of Nusselt numbers were obtained from the heat transfer data. (author)

1999-07-01

100

Condensation heat transfer in a steam-water stratified flow  

International Nuclear Information System (INIS)

Fundamental phenomena of condensation heat transfer at a steam-water interface have been studied related to the thermo-hydrodynamics of the emergency core cooling system for light water reactors. In this study temperature fluctuations near the interface and in the liquid phase were measured using fine thermocouples for a saturated steam-subcooled water co-current stratified two-phase flow in a nearly horizontal rectangular channel, and heat transfer coefficients were determined experimentally. The values of the condensation heat transfer coefficients in this experiment are from 6 to 40 kW/m"2K. In the regions of high Reynolds numbers, as the steam Reynolds numbers become larger, the average interfacial heat transfer coefficients tend to increase. The corelations of Nusselt numbers were obtained from the heat transfer data. (author)

1999-04-19

101

Analysis of WITCH/LINER experiments on heat transfer between gas-agitated steel melt and vertical wall  

Energy Technology Data Exchange (ETDEWEB)

The analysis for the WITCH/LINER experiments was performed to investigate the heat transfer characteristics between the gas-agitated steel melt and the vertical surface. The applicability of heat transfer correlations for a gas-agitated fluid system was examined through the numerical analysis of the one-dimensional heat conduction taking into account the crust formation due to the solidification of the steel melt. The heat transfer correlation developed by Konsetov was modified for the application to fluids with low Prandtl number. The constant in the modified correlation was empirically found mainly through the comparison between the analysis and the experiments under conditions that a churn-turbulent two-phase flow regime was anticipated to form. The modified Konsetov correlation could predict the heat transfer characteristics observed through the experiments ...

1999-10-01

102

Effect of heat transfer augmentation by square rod array in impinging air jet system(heat transfer characteristic of potential core region)  

Energy Technology Data Exchange (ETDEWEB)

This research has been proceeded over the potential core region (H/B=2) of two-dimensional impinging air jet system, in which square rods(width of 6 mm) has been set up in front of heating surface in order to increase heat transfer. The objective of this research was to investigate the characteristics of heat transfer and air flow, in cases of the clearance from rods to heating surface (C = 1, 2, 4, 6 mm) and the pitch between each rods(P = 30, 40, 50 mm) changed. And this research compared the above with the experimentation without rods. As result, heat transfer performance was best under the condition of C = 1 mm, in case clearance changed, and there was no serious difference in the effect of heat transfer augmentation in the case of pitch of rods changed. (author) 11 refs. 12 figs.

1995-07-01

103

Waste heat recovery systems in the sugar industry: An Indian perspective  

Energy Technology Data Exchange (ETDEWEB)

This article identifies the key role of the sugar industry in the rural development of developing countries. The Indian sugar industry, already second largest among the country`s processing industries, shows even greater potential, according to the Plan Documents (shown in a table). The potential of waste heat in sugar processing plants, which produce white crystal sugar using the double sulphitation clarification process, is estimated at 5757.9 KJ/kg of sugar. Efficient waste heat recovery (WHR) systems could help arrest the trend of increasing production costs. This would help the sugar industry not only in India, but in many other countries as well. The innovative methods suggested and discussed briefly in this article include dehydration of prepared cane, bagasse drying, and juice heating using waste heat. These methods can reduce the cost of energy in sugar production by at ...

1996-04-01

104

Atomic mechanism of glass-to-liquid transition in simple monatomic glasses  

British Library Electronic Table of Contents (United Kingdom)

The atomic mechanism of a glass-to-liquid transition in a monatomic Lennard-Jones (LJ) glass was studied using the molecular dynamics (MD) method. Glassy models were heated up from low temperature at two different heating rates and a glass-to-liquid transition found to occur at the higher heating rate. The temperature dependence of the potential energy, mean-squared-displacements (MSD) of the atoms and the self-intermediate scattering function indicate clearly that a glass transition occurs in the system. The atomic mechanism of the glass-to-liquid transition was investigated by analyzing the spatio-temporal arrangement of liquid-like atoms in the system upon heating. Liquid-like atoms were detected using the Lindemann-melting-like criterion. Upon heating, liquid-like atoms occur at temper...

2011-01-01

105

Heat pump modeling in TRNSYS  

Energy Technology Data Exchange (ETDEWEB)

Versatility of the TRNSYS software program, the ease with which new components can be incorporated into the software, and its application to simulate heat pump systems was discussed. A case history was described in which the package, augmented by the addition of several recent large-scale heat pump projects, was used in calibrating a residential geothermal heat pump system at a military housing project in Fort Polk, LA. The project involved retrofitting over 4000 air source heat pumps with geothermal heat pumps in an energy savings performance contract. The calibration of the component models led to a system model which accurately predicts the performance of the geothermal heat pump. The lessons learned from the calibration exercise were used to help to predict the energy savings from one of the ...

1997-11-01

106

FY 1998 annual report on the survey on development, introduction and promotion of urban type multipurpose geothermal utilization techniques; 1998 nendo toshigata tamokuteki chinetsu riyo gijutsu no kaihatsu, donyu, sokushin ni kansuru chosa hokokusho  

Energy Technology Data Exchange (ETDEWEB)

Introduction of geothermal heat pump systems, which depend on temperature differential, is investigated for urban areas, which have large energy demands. Results of the surveys on the current situations of geothermal heat pump (GHP) systems indicate that they have already numbered 300,000 units in USA and totaled more than 50,000 units in Switzerland and Northern European countries, and that they are increasing at an annual rate of higher than 10%. The results also indicate that introduction of these systems are well feasible in Japan, which generally has better topographical conditions than American and European countries, and the GHP system with vertical ground heat exchanger is investigated for its topographical and environmental considerations. These systems could annually abate approximately 52 million tons of CO2 ...

1999-03-01

107

United States Gypsum Plant Solar Retrofit Program  

Energy Technology Data Exchange (ETDEWEB)

A conceptual design of a solar retrofit to US Gypsum's plant at Sweetwater, Texas, has been developed which provides heated air to a large gypsum board drying kiln that is currently under construction. The solar heated air displaces natural gas normally used for the process heat. The solar retrofit is composed of a tower focus collector with a cavity receiver which uses air as the heat transfer fluid. An executive summary of the conceptual design, system performance, economics, and development plan is presented. (WHK)

1980-07-01

108

Effect of microwaves on microorganisms in foods  

Energy Technology Data Exchange (ETDEWEB)

The microbial safety of foods cooked in microwave ovens was investigated. The mechanisms of microwave destruction of microorganisms were examined. Effects of time and temperature on microorganisms in different food systems were described. Studies showed that: microwave heating of food is more ''''food dependent'' than conventional heating; recommended microwave treatment time for some foods may not destroy high levels of bacteria; use of microwaves in combination with conventional heating methods results in more uniform heating of foods and destruction of bacteria; and microwaves exert different killing effects on individual bacterial species. (78 references, 2 tables)

1980-08-01

109

IEA HPP Annex 29 - ground-source heat pumps overcoming technical and market barriers. Status report Norway  

International Nuclear Information System (INIS)

Norway is a member of Annex 29, 'Ground-Source Heat Pump Systems Overcoming Technical and Market Barriers' (2004-2006), organized under the umbrella of the International Energy Agency (IEA) and the IEA Heat Pump Programme (HPP). The 7 participating countries are Austria (Operating Agent), Canada, Japan, Norway, Spain, Sweden and the USA. The Norwegian participation is financed by ENOVA SF, and SINTEF Energy Research is responsible for planning and carrying out the Norwegian activities. This report provides a status for ground-source heat pump (GSHP) systems in Norway with regard to state-of-the-art technology, installation examples, geological data, costs and market opportunities. A Norwegian Internet home page for ground-source heat pump systems (www.energy.sintef.no/prosjekt/Annex29) is also presented. GSHP systems in ...

110

Application of automatic inspection system to nondestructive test of heat transfer tubes of primary pressurized water cooler in the high temperature engineering test reactor. Joint research  

International Nuclear Information System (INIS)

Heat transfer tubes of a primary pressurized water cooled (PPWC) in the high temperature engineering test reactor (HTTR) form the reactor pressure boundary of the primary coolant, therefore are important from the viewpoint of safety. To establish inspection techniques for the heat transfer tubes of the PPWC, an automatic inspection system was developed. The system employs a bobbin coil probe, a rotating probe for eddy current testing (ECT) and a rotating probe for ultrasonic testing (UT). Nondestructive test of a half of the heat transfer tubes of the PPWC was carried out by the automatic inspection system during reactor shutdown period of the HTTR (about 55% in the maximum reactor power in this paper). The nondestructive test results showed that the maximum signal-to-noise ratio was 1.8 in ECT. Pattern and phase of Lissajous wave, which were obtained for the ...

111

Reflux boiling heat removal in a scaled TMI-2 system test facility  

International Nuclear Information System (INIS)

An investigation of decay heat removal by the reflux boiling process was performed on a 1/18 linear-scaled test facility simulating the Three Mile Island (TMI-2) primary system. The objective was to clarify reflux boiling phenomena and core cooling effectiveness. Principal test variables included: core power, primary system water and gas inventories, and steam generator secondary-side coolant flow rate. Of 49 tests conducted, 43 achieved a steady-state heat rejection mode within 3 hours. Subsequent analyses identified two distinct reflux boiling modes. Based upon our current understanding, reflux boiling appears to be an effective process for removing decay heat in a broad range of the conditions investigated for a plant of the TMI configuration.

1980-06-01

112

Passive solar design handbooks: Vol III: passive solar design analysis and supplement  

Energy Technology Data Exchange (ETDEWEB)

This book applies the Los Alamos Solar Load Ratio (SLR) method to the design of passive solar heating systems, with an emphasis on the average annual heating energy consumption. Recommendations are given on minimizing heating energy consumption by appropriate choices of conservation level and solar system parameters. Analytical methods and supporting tables are presented which enable simple, fast estimates of the heating energy consumption as part of the design process. Topics considered include SLR correlations, the load collector ratio (LCR) method, sensitivity data, cooling considerations, conservation formulas, design procedure, life-cycle costs, high-mass direct gain buildings, low-mass sun-tempered buildings, sunspaces, off-reference night insulation, correlation equations, and mixed systems.

1983-01-01

113

Effects of population allocation of the electric power systems from the viewpoint of combined heat and power installation  

Energy Technology Data Exchange (ETDEWEB)

Recently it is strongly required to reduce energy consumption to cope with the global warming. Since energy consumption in commercial and residential sectors are increasing while industrial sector is almost constant in Japan, policies to lead energy conservation in urban areas is quite important. This study aims at investigating the performance of urban energy systems which install combined heat and power (CHP) as a district heating and cooling (DHC) plant and the influence of CHP on the structure of electric power systems of utilities. The behavior of energy technologies and the possibility of energy conservation are evaluated based on an optimization model with respect to total system cost. Sensitivity analysis of population allocation into urban areas indicates that fossil fuel consumption varies in the range of 10--20% compared with conventional systems.

1997-12-31

114

Humidification dehumidification desalination process: Design and performance evaluation  

British Library Electronic Table of Contents (United Kingdom)

This paper focuses on the design and modeling of the humidification dehumidification desalination (HDH) process. The process is only found on experimental or very small pilot scale. Literature studies are rather limited and it includes a number of experimental investigations, performance evaluation, and measurements of the heat and mass transfer coefficients. This study includes useful and new data on the evaluation of the heat transfer coefficient of the humid air stream in the condenser unit. The analysis develops a correlation for the heat transfer coefficient for the humid air stream as a function of the Reynolds and Prandtl numbers. Also, detailed evaluation of the system performance is presented as a function of the system temperatures and the inlet relative humidity of the air strea...

2008-01-01

115

Geothermal heat pump performance and utility programs in the United States  

Energy Technology Data Exchange (ETDEWEB)

Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past 10 years in the United States. These systems offer substantial benefits to consumers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data were available mainly from electric utilities on heat pump performance, energy savings, and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market entry, incentive programs, and benefits.

1997-01-01

116

Geothermal heat pump performance  

Energy Technology Data Exchange (ETDEWEB)

Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to customers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market penetration, incentive programs, and benefits.

1995-12-31

117

Energy conservation by means of integrated systems; Beter resultaat door klimaatkwartet  

Energy Technology Data Exchange (ETDEWEB)

Air conditioning is getting maximum attention these days when building new offices. For the new office building of the assurance company Zwitserleven in Amstelveen, Netherlands, a new air conditioning concept is applied, based on four existing air conditioning methods: cold storage and heat storage in the soil, heat pump, double-wall facades with integrated climate control, and radiant heating combined with a cooling system in the ceiling. The integration of these methods not only provides complete climate comfort for the employees but also substantial energy savings. 3 figs.,1 ills.

1995-11-01

118

Off peak geothermal heat pump storage system  

Energy Technology Data Exchange (ETDEWEB)

The basic design of a system installed in the Columbus, Ohio Zoo is described. The distribution system is described in detail. The control system is microprocessor controlled, with about 50 monitoring points. Preliminary evaluations have indicated that the system can operate with an overall coefficient of performance in excess of 3.5. 1 figure.

1986-03-01

119

Regulation about the technical environment of buildings: boiler-rooms / ventilation systems; RETA: chaufferies / ventilation  

Energy Technology Data Exchange (ETDEWEB)

This CD-Rom edited by the French scientific and technical committee of the space heating, ventilation and air-conditioning industry (CoSTIC) presents a series of technical files about ventilation and space heating systems with several references to the current regulatory texts. Modifications of the original legislative texts have been integrated to the original texts for a more comfortable reading. Search is performed using diagrams and key-words. (J.S.)

2000-06-01

120

Radisson community heating systems: technical and economic comparison of options. Final report  

Energy Technology Data Exchange (ETDEWEB)

The study reported was conducted to evaluate water source community heat pump systems for possible installation to serve a number of homes which are to be constructed in the northeast section of Radisson, New York. Although specific sites and facilities have been evaluated, it is the intent of this study to be site specific only to the extent of climatic conditions. In other words, the results of this study should apply to any area with similar climate.

1981-12-01

121

Radionuclide buildup in FFTF [Fast Flux Test Facility] heat transport system cells  

International Nuclear Information System (INIS)

The purpose of the work reported in this paper was to measure the radionuclide buildup in primary heat transport system cell No. 3 at the Fast Flux Test Facility (FFTF) and to compare the results with predicted values from a model based on experimental studies and experience at similar reactors. The information obtained is used for maintenance planning and to enhance ability to assess radionuclide buildup in the future at FFTF and in other reactors.

1989-11-26

122

A thermal valve heat flux control device  

International Nuclear Information System (INIS)

In order to evacuate the residual power in a nuclear reactor, a thermal valve system is presented for the modification of the heat exchange conditions at the pool exchanger level, which avoids the use of mechanical valves on the pipes. The system involves a vessel containing the exchanger, with openings at the upper end of the vessel and means for feeding the fluid at the lower end, and means for controlling the opening width.

1994-10-05

123

Development of a gas turbine combined cycle and co-generation plant computer aided engineering system; Fukugo cycle hatsuden netsuden heikyu plant sekkei shien system no kaihatsu  

Energy Technology Data Exchange (ETDEWEB)

Kawasaki Heavy Industries, Ltd. has developed a gas turbine combined cycle and cogeneration plant computer aided engineering (CAE) system, which creates cycle heat balance automatically on given configurations of gas turbines, heat recovery boilers, steam turbines and auxiliaries. The system can predict the performance of the plant as a function of control set points, loads, process steam requirements and ambient conditions, which enables accurate and fast design of gas turbine combined cycle and cogeneration plants. (author)

1999-04-01

124

Cogeneration and beyond: The need and opportunity for high efficiency, renewable community energy systems  

International Nuclear Information System (INIS)

The justification, strategies, and technology options for implementing advanced district heating and cooling systems in the United States are presented. The need for such systems is discussed in terms of global warming, ozone depletion, and the need for a sustainable energy policy. Strategies for implementation are presented in the context of the Public Utilities Regulatory Policies Act and proposed new institutional arrangements. Technology opportunities are highlighted in the areas of advanced block-scale cogeneration, CFC-free chiller technologies, and renewable sources of heating and cooling that are particularly applicable to district systems.

2007-10-15

125

Safety System Design Concept and Performance Evaluation for a Long Operating Cycle Simplified Boiling Water Reactor  

Science.gov (United States)

The long operating cycle simplified boiling water reactor is a reactor concept that pursues both safety and the economy by employing a natural circulation reactor core without a refueling, a passive decay heat removal, and an integrated building for the reactor and turbine. Throughout the entire spectrum of the design basis accident, the reactor core is kept covered by the passive emergency core cooling system. The decay heat is removed by the conventional active low-pressure residual heat removal system. As for a postulated severe accident, the suppression pool water floods the lower part of the reactor pressure vessel (RPV) in the case when core damage occurs, and the in-vessel retention that keeps the melt inside the RPV is achieved by supplying the coolant. The containment adopts a parallel-double-steel-plate structure similar to a hull structure, which contains coolant between ...

2003-07-15

126

Convection heat loss from cavity receiver in parabolic dish solar thermal power system: A review  

Energy Technology Data Exchange (ETDEWEB)

The convection heat loss from cavity receiver in parabolic dish solar thermal power system can significantly reduce the efficiency and consequently the cost effectiveness of the system. It is important to assess this heat loss and subsequently improve the thermal performance of the receiver. This paper aims to present a comprehensive review and systematic summarization of the state of the art in the research and progress in this area. The efforts include the convection heat loss mechanism, experimental and numerical investigations on the cavity receivers with varied shapes that have been considered up to date, and the Nusselt number correlations developed for convection heat loss prediction as well as the wind effect. One of the most important features of this paper is that it has covered numerous cavity literatures encountered in various other engineering ...

2010-08-15

127

Experimental simulation of heat transfer augmentation by break-jets in passive containment cooling system  

International Nuclear Information System (INIS)

The studies of forced jet augmentation of natural convection heat transfer are introduced. It investigates experimentally mixed convection and heat transfer augmentation by forced jets in a large rectangular enclosure with a vertical cooling surface. The experiment is designed to measure the key parameters governing the heat transfer augmentation by a forced jet, and to investigate the effects of geometric factors, including the jet diameter, jet injection orientation, interior structures, and enclosure aspect ratio, on conditions simulating those of actual passive containment cooling systems and scales approaching those of actual containment buildings or compartments. The tests that cover a variety of injection modes will contribute to reveal the nature of mixing and stratification phenomena under accident conditions to a new generation of inherently safe reactors. With similarity considerations on ...

2010-02-01

128

Design of a closed 4 MW spallation target module with heat removal system for an ADS system  

International Nuclear Information System (INIS)

At the Forschungszentrum Karlsruhe the HGF Strategy Fund project entitled 'Innovative Technology to Reduce Radiotoxicity' is performed which delivers an essential scientific contribution to the application oriented fundamental research for Accelerator Driven Systems (ADS). The addressed topics are in the areas of heavy liquid metal technology, thermalhydraulics and materials / corrosion. An ADS consists of three main components: an proton accelerator, a spallation target and a subcritical blanket. The strategic objective of an ADS is the transmutation of long-lived radioactive waste (plutonium, minor actinides and long-lived fission products) into short-lived isotopes or stable elements, thus closing the fuel cycle. The objective of one task of the HGF Strategy Fund Project is the numerical calculation of a closed spallation target module. In a consequent next step such a spallation target can be experimentally investigated at IKET and the numerical results can be ...

129

Surface wettability effect on an indirect evaporative cooling system  

Energy Technology Data Exchange (ETDEWEB)

Indirect evaporative air coolers that use air-to-air plate-type heat exchangers show good promise (compared with compression air-conditioning systems) of extending the energy savings from arid, low-humidity areas to more widespread climatic conditions. However, no systematic experiment had been done concerning the effect of the wettability of aluminum plates on the effectiveness of the indirect evaporative cooling system. In this study, a testing apparatus was built where only one secondary channel and two primary channels were used so that different surfaces could be easily tested to determine the system`s effectiveness and the heat transfer coefficient. The advantage of this experimental apparatus is that plates of the heat exchanger can be easily changed in the test section instead of fabricating a complete heat exchanger for each test. A ...

1996-11-01

130

Solar desalination using humidification dehumidification processes. Pt. 1. A numerical investigation  

Energy Technology Data Exchange (ETDEWEB)

A numerical investigation of a humidification dehumidification desalination (HDD) process using solar energy is presented. The HDD system consists mainly of a concentrating solar water heating collector, flat plate solar air heating collector, humidifying tower and dehumidifying exchanger. Two separate circulating loops constitute the HDD system, the first for heating the feed water and the second for heating air. A mathematical model is developed, simulating the HDD system, to study the influence of the different system configurations, weather and operating conditions on the system productivity. The model validity is examined by comparing the theoretical and experimental results of the same authors. It is found that the results of the developed mathematical model are in good agreement with the ...

2004-05-01

131

Solar desalination using humidification dehumidification processes. Part I. A numerical investigation  

Energy Technology Data Exchange (ETDEWEB)

A numerical investigation of a humidification dehumidification desalination (HDD) process using solar energy is presented. The HDD system consists mainly of a concentrating solar water heating collector, flat plate solar air heating collector, humidifying tower and dehumidifying exchanger. Two separate circulating loops constitute the HDD system, the first for heating the feed water and the second for heating air. A mathematical model is developed, simulating the HDD system, to study the influence of the different system configurations, weather and operating conditions on the system productivity. The model validity is examined by comparing the theoretical and experimental results of the same authors. It is found that the results of the developed mathematical model are in good agreement with the ...

2004-05-01

132

Large temperature differential thermal storage system. Its design and evaluation  

Energy Technology Data Exchange (ETDEWEB)

A large temperature differential (10K) thermal storage system in a small (4400 m{sup 2}) 8-storey office building is discussed and the monitoring results are analyzed in comparison with computer simulations. Requirements were a comfortable indoor environment and system cost effectiveness. Out of four potential system concepts, the Large Temperature Differential System was chosen. It comprises a flat-type thermal stratification heat storage tank in the under floor pit of the building as the heat source for a variable flow heat pump chiller. The heat sink is a set of serially connected air handling and fan coil units. The tank`s capacity is sized for one day operation and is made as large as possible to shift the electricity demand to night time. To avoid a large size and high cost, the water temperature differential was ...

1996-07-01

133

Thermal energy storage system using stearic acid as a phase change material  

Energy Technology Data Exchange (ETDEWEB)

The thermal performance and phase change stability of stearic acid as a latent heat energy storage material has been studied experimentally. The thermal performance and heat transfer characteristics of the stearic acid were tested and compared with other studies given in the literature. In the present study, parameters such as transition times, temperature range and propagation of the solid-liquid interface as well as the effect of heat flow rate on the phase change stability of stearic acid as a phase change material (PCM) were studied. The experimental results showed that the melting stability of the PCM is better in the radial direction than in the axial direction. The variation in the melting and solidification parameters of the PCM with the change of inlet water temperature is also studied. We observed that while the heat exchanger tube is in the horizontal position, the PCM has more effective and ...

2001-07-01

134

SUSTAINABLE H/C SYSTEMS FOR CHICKEN FARMS IN SYRIA  

Energy Technology Data Exchange (ETDEWEB)

Space heating/cooling systems account for approximately 30% of the global energy consumption. Such systems contribute to global warming by emitting 0.39.1011 MWh of heat and 2.9.1010 tons of CO{sub 2}. There is a general understanding that the way to reduce global warming is a more efficient use of energy and increased use of renewable energy in all fields of the society. The poultry industry in the Mid East is an important business. There are e.g. 13000 chicken farms in Syria producing 172,000 ton of meat. This industry employs directly almost 150,000 people. The total investment in chicken farming is 130 BSP. Even though, the annual mean temperature in Syria is {approx}15-18 C the winter temperatures are close to freezing for two months. Since the chickens need a temperature of 21-35 C, depending on age, approximately 168.103 tons of coal (1170 GWh) is consumed for heating these ...

2008-09-30

135

An experimental integrated absorption heat pump effluent purification system. Pt. 1: Operating on water/lithium bromide solutions  

Energy Technology Data Exchange (ETDEWEB)

The merits of single stage absorption heat pumps coupled to simple distillation for effluent treatment are discussed. An experimental integrated absorption heat pump effluent purification system (IAHPEPS) was built and operated with water-lithium bromide as a working mixture. This unit has been used to raise the temperature and hence, the vapour pressure of the impure water contained in one vessel, to the point where pure water vapour will distil from impure effluent solution (tap water or brine) and condense in a second vessel used to collect pure water. Pure effluent production rates of between 0.5 and 4.3 kg h{sup -1} were obtained. The actual coefficient of performance (COP{sub A}) and the heat pump effectiveness varied from 1.1 to 1.4 and 0.58 to 0.72, respectively. The results from the small scale systems indicate the likely results from industrial scale units which could be ...

1999-05-01

136

Finalisation of design provision for active process water system shut down at TAPP-3 and 4  

International Nuclear Information System (INIS)

Active Process Water (APW) system is provided as a unitized system in TAPP-3 and 4. Maintenance on APW system requires shutdown of this system. As shut down heat exchangers are fed by APW system; during APW system shutdown cold shutdown state cannot be maintained. Therefore safety analysis is done to optimize the duration of reactor shutdown (which means low decay heat) after which APW shutdown can be taken with minimum water supply to the shutdown heat exchangers. Based on this analysis, it is proposed in technical specification that APW system shutdown can be taken after 7 days of reactor shutdown with shutdown heat exchangers supplied with about 20 % of normal APW flow. With this configuration, PHTS, moderator, end shield, calandria vault water temperature ...

2006-11-13

137

GRI's Gas Appliance Technology Center Activities at Battelle. Final report, 1986-1992  

Science.gov (United States)

The Gas Research Institute established the Gas Appliance Technology Center (GATC) in 1982 to develop improved gas appliances. Between 1986 and 1992, the scope of GATC activities at Battelle included technology transfer and overall industry support, residential appliances, commercial appliances, and residential space conditioning. The following tasks are representative of the GATC activities described in the report; gas burner technology, appliance venting, emissions, water heating, range/oven technology, self-powered appliances, commercial cooktop burners, reconstituting ovens, appliance reliability improvement, combination space-heating/water-heating systems, condensing heat exchangers, corrosion testing, and space heating technology. The report includes references to available sources for further reading.

1993-08-01

138

Evaluation of Enova's heating programs; Evaluering av Enovas varmeprogrammer  

Energy Technology Data Exchange (ETDEWEB)

An evaluation of Enova's heating program is presented. The central point was to evaluate to which degree Enova's heating program had resulted in increased supply of renewable energy for heating purposes to the Norwegian energy system. Main results are presented in part 1, chapter 1 to 5, while the facts and analyses behind the evaluation are presented in part 2, chapter I to VII. The main conclusion is that the program seen as one has had triggering effect on the market. The program has thus provided results in the form of increased supply of heating energy. Because of the project limitations and the lack of systematically documented baselines in the procedures, there are insecurities connected to the exact data registered. This makes quantification of the results difficult (ml)

2006-07-01

139

Combined effect of magnetic field and heat absorption on unsteady free convection and heat transfer flow in a micropolar fluid past a semi-infinite moving plate with viscous dissipation using element free Galerkin method  

British Library Electronic Table of Contents (United Kingdom)

The fully developed electrically conducting micropolar fluid flow and heat transfer along a semi-infinite vertical porous moving plate is studied including the effect of viscous heating and in the presence of a magnetic field applied transversely to the direction of the flow. The Darcy-Brinkman-Forchheimer model which includes the effects of boundary and inertia forces is employed. The differential equations governing the problem have been transformed by a similarity transformation into a system of non-dimensional differential equations which are solved numerically by element free Galerkin method. Profiles for velocity, microrotation and temperature are presented for a wide range of plate velocity, viscosity ratio, Darcy number, Forchhimer number, magnetic field parameter, heat absorption ...

2010-01-01

140

Recovery of Water from Boiler Flue Gas  

Energy Technology Data Exchange (ETDEWEB)

This project dealt with use of condensing heat exchangers to recover water vapor from flue gas at coal-fired power plants. Pilot-scale heat transfer tests were performed to determine the relationship between flue gas moisture concentration, heat exchanger design and operating conditions, and water vapor condensation rate. The tests also determined the extent to which the condensation processes for water and acid vapors in flue gas can be made to occur separately in different heat transfer sections. The results showed flue gas water vapor condensed in the low temperature region of the heat exchanger system, with water capture efficiencies depending strongly on flue gas moisture content, cooling water inlet temperature, heat exchanger design and flue gas and cooling water flow rates. Sulfuric acid vapor condensed in both the high temperature ...

2008-09-30

141

Two-phase flow instabilities in a single channel with enhanced heat transfer, and pressure-drop type oscillation thresholds  

International Nuclear Information System (INIS)

In recent years, there has been increased emphasis on techniques to enhance two-phase flow heat transfer. The resulting increase in the use of heat transfer augmentation and the engineering importance of the subject presents this investigation in order to study the effect of different heater surface configurations on two-phase flow instabilities. The authors present the results of an experimental and theoretical study, summarized as: instabilities are not affected by small changes in heat transfer; nucleate boiling increases system unstability; amplitude of the oscillations increases as the axial temperature gradient over the heater increases; for the same type heater surfaces system stability increases with decreasing equivalent diameter; period of the oscillations depend on the heater surfaces; and linearized analysis and steady-state data can be used to determine the oscillation ...

1985-10-01

142

Thermal control of electric vehicle batteries  

Energy Technology Data Exchange (ETDEWEB)

The need to operate electric vehicles in warm, summer conditions and also provide for long periods of standby in cold climates is a challenging problem for any battery system. All advanced batteries of high specific energy require active cooling systems because adiabatic heating will raise the temperature to a level that is deleterious to cycle life. This cooling requires efficient paths for escape of heat to cooled surfaces; cooling the exterior of modules is insufficient. If a battery is heated by its own energy, and insulated to withstand exposure to a cold climate, only vacuum insulation will afford an appreciable reduction (>10{degrees}C) in the ambient temperature that can be tolerated. Standard insulations are of little use for this purpose because the heat loss rate causes too high a drain on the battery energy even for near-ambient temperature ...

1995-07-01

143

An economic planning tool for geothermal energy projects  

Energy Technology Data Exchange (ETDEWEB)

Three geothermal direct heat applications were examined to derive a set of cost estimates from which one could determine the effect of changes in system parameters (temperature, flow, load, etc.) on the cost of heat. For each application, a set of resource characteristics and system inputs were chosen to best represent a site specific baseline condition. The baseline estimated cost of heat was calculated along with other cost estimates representing optimistic and pessimistic conditions, bracketing the range any input variable might reasonably take. Regression equations based upon these cost estimates were developed for each application to quantitatively relate changes in cost to changes in the input variables. These three equations and their accompanying nomographs serve as easily understandable planning tools for direct heat geothermal energy projects.

1980-12-01

144

Low temperature heating systems. More comfort with less energy; Lage temperatuursystemen. Meer comfort met minder energie  

Energy Technology Data Exchange (ETDEWEB)

To realise the Dutch objectives of energy saving and emission reductions in the built environment, the use of 'Low Valued Energy' will be necessary in the future. Low Valued Energy is available from residual, ambient heat and renewable sources. Using Low Valued Energy for space heating in commercial and residential buildings requires adjusting the design of the installations, i.e. lowering the design supply temperature of the heating system from 90C to 55C or less. Appropriate heat distribution systems, e.g. floor or wall heating and radiators, have a life cycle of 40 to 50 years. The application (on a large scale in buildings), however, requires an enormous change in the installation and building branch. To enable the application of low temperature sources in the future, the building and installation designs should be ...

2000-06-01

145

A thermochemical hydrogen production system based on a high-temperature fusion reactor blanket  

International Nuclear Information System (INIS)

A conceptual fusion synfuel production system has been developed with the unique features of: (1) a fusion blanket producing high-temperature (1250"0C) process heat, and (2) the GA sulfur-iodine thermochemical cycle. The system incorporates a two-zone blanket which achieves a tritium breeding ratio of 1.1 while delivering a high fraction (30%) of the fusion heat at high temperatures (1250"0C). The multiple barriers to tritium permeation in the blanket design permit the hydrogen product to meet 10CFR20 regulatory requirements without stringent requirements on the tritium recovery systems. A ceramic heat exchanger, incorporating SiC tubes and headers to contain the process stream and a cooled, Inconel 718 pressure shell to contain the helium, was designed for transferring the heat from the high-temperature coolant to the process. A good ...

1983-04-26

146

Thermal and heat transfer characteristics in a latent heat storage system using lauric acid  

Energy Technology Data Exchange (ETDEWEB)

The thermal and heat transfer characteristics of lauric acid during the melting and solidification processes were determined experimentally in a vertical double pipe energy storage system. In this study, three important subjects were addressed. The first one is temperature distributions and temporal temperature variations in the radial and axial distances in the phase change material (PCM) during phase change processes. The second one is the thermal characteristics of the lauric acid, which include total melting and total solidification times, the nature of heat transfer in melted and solidified PCM and the effect of Reynolds and Stefan numbers as inlet heat transfer fluid (HTF) conditions on the phase transition parameters. The final one is to calculate the heat transfer coefficient and the heat flow rate and also discuss the role of Reynolds and Stefan numbers ...

2002-12-01

147

http-equiv=\\  

Wastenet

may be possible to meet those loads with renewable energy systems &mdashachieving zero-net- energy performance.Solar-thermal heating systems, ...p/p Spencer and others argue that renewable energy systems should be considered only after the building envelope ...energy loads are brought low enough, however, a renewable energy system may make sense financially. p

148

Effect of the PVC system?s topology on the dielectric losses in the region of strong electric fields  

British Library Electronic Table of Contents (United Kingdom)

The electrophysical characteristics of the electric cable?s transition into a state of a heterogenic polymer system due to a wire?s explosion were examined. Using cyclic heating-cooling of the composite, the changes in its topology were observed. The latter makes it possible to regulate the dielectric characteristics of the system.

2011-01-01

149

Overview of Cooling Water System for the KSTAR 1st Plasma Experiment  

International Nuclear Information System (INIS)

The KSTAR cooling water system (CWS) consists of a primary cooling water system (PCWS), a secondary cooling water system (SCWS), and a de-mineralizing and de-ionized water system (DIWS). The PCWS cooling loops have been made for the poloidal field (PF) and toroidal field (TF) magnet power supplies (MPS), vacuum vessel (VV), electron cyclotron heating (ECH), ion cyclotron heating (ICRH), vacuum pumps, diagnostics, helium facility, etc. The CWS had been done individual commissioning of each system to confirm the design specifications by the end of 2006 and had gradually begun operation for the KSTAR ancillary devices by March 2008

2009-05-01

150

Mold heating and cooling microprocessor conversion. Final report  

Energy Technology Data Exchange (ETDEWEB)

Conversion of the microprocessors and software for the Mold Heating and Cooling (MHAC) pump package control systems was initiated to allow required system enhancements and provide data communications capabilities with the Plastics Information and Control System (PICS). The existing microprocessor-based control systems for the pump packages use an Intel 8088-based microprocessor board with a maximum of 64 Kbytes of program memory. The requirements for the system conversion were developed, and hardware has been selected to allow maximum reuse of existing hardware and software while providing the required additional capabilities and capacity. The new hardware will incorporate an Intel 80286-based microprocessor board with an 80287 math coprocessor, the system includes additional memory, I/O, and RS232 communication ports.

1995-07-01

151

Flow Vaporization of CO{sub 2} in Microchannel Tubes  

Energy Technology Data Exchange (ETDEWEB)

Carbon dioxide is receiving renewed interest as an efficient and environmentally safe refrigerant in a number of applications, including mobile air conditioning and heat pump systems, and hot water heat pumps. Compact heat exchangers for CO{sub 2} systems are designed with small-diameter tubing. The purpose of this study is therefore to provide a better basis for understanding and predicting heat transfer and pressure drop during flow vaporization of CO{sub 2} in microchannels. The ''unusual'' properties of carbon dioxide give heat transfer and two-phase flow characteristics that are very different from those of conventional refrigerants. Examples of these differences are the much higher pressure, the resulting high vapour density, a very low surface tension, and a low liquid viscosity. High pressure and ...

2002-07-01

152

Evaluation of heat exchange rate of GHE in geothermal heat pump systems  

Energy Technology Data Exchange (ETDEWEB)

Total thermal resistance of ground heat exchanger (GHE) is comprised of that of the soil and inside the borehole. The thermal resistance of soil can be calculated using the linear source theory and cylindrical source theory, while that inside the borehole is more complicated due to the integrated resistance of fluid convection, and the conduction through pipe and grout. Present study evaluates heat exchange rate per depth of GHE by calculating the total thermal resistance, and compares different methods to analyze their similarities and differences for engineering applications. The effects of seven separate factors, running time, shank spacing, depth of borehole, velocity in the pipe, thermal conductivity of grout, inlet temperature and soil type, on the thermal resistance and heat exchange rate are analyzed. Experimental data from several real geothermal heat pump (GHP) applications in Shanghai are ...

2009-12-15

153

A study on heat-transfer enhancement by a square-rod array in an impinging jet system  

Energy Technology Data Exchange (ETDEWEB)

An impinging jet is a widely used technique for realizing high heat-transfer rates between a fluid and a surface. However, the area of enhanced heat transfer is limited to the neighborhood of the stagnation point. In this study, heat transfer is augmented remote from the stagnation point in an impinging plane jet system by a rod array located near the wall. Each square rod in the array was positioned normal to the flow direction and parallel to the flat plate surface. The distance between the nozzle and the flat plate (H) and the spacing between the rods and the flat plate surface (C) were changed to find the optimum values. The largest heat-transfer augmentation was obtained for C = 1 mm, H/B = 10, where the jet nozzle width is B. In this case, the heat-transfer coefficient averaged over an area 2B from the stagnation point is about 1.6 times greater compared ...

1996-07-01

154

TPC magnet cryogenic system  

Energy Technology Data Exchange (ETDEWEB)

The Time Projection Chamber (TPC) magnet at LBL and its compensation solenoids are adiabatically stable superconducting solenoid magnets. The cryogenic system developed for the TPC magnet is discussed. This system uses forced two-phase tubular cooling with the two cryogens in the system. The liquid helium and liquid nitrogen are delivered through the cooled load by forced tubular flow. The only reservoirs of liquid cryogen exist in the control dewar (for liquid helium) and the conditioner dewar (for liquid nitrogen). The operation o these systems during virtually all phases of system operation are described. Photographs and diagrams of various system components are shown, and cryogenic system data are presented in the following sections: (1) heat leaks into the TPC coil package and the compensation solenoids; (2) ...

1980-03-01

155

Experimental study and performance evaluation of convective heat transfer augmentation with coiled wire inserts  

Energy Technology Data Exchange (ETDEWEB)

An experimental study of forced convection heat transfer at the inner tube wall of a double pipe heat exchanger with coiled wire inserts as heat transfer augmentation devices was performed over a turbulent flow region. The test results from twelve augmented tubes with inserts of different combinations of wire diameters (0.813, 1.016 and 1.575 mm) and pitches (2.82, 3.63, 5.08 and 8.47 mm) indicate that the turbulence promoters studied improve heat transfer by a factor of 1.4 to 2.24 compared with a smooth tube, although at a cost of 10-30 times increase in friction factor. A formula for presenting dimensionless exergy losses in a tubular heat exchanger is derived first and then the thermohydrodynamic optimum instead of economic optimum is found by minimizing the exergy losses in the system. From the heat transfer improvement number defined, ...

1992-12-01

156

Sophisticated applications of radiation heat transfer  

International Nuclear Information System (INIS)

A large amount of energy has been consumed so far in so called matured industries such as iron and steel, oil refinery, petrochemical, ceramic, paper and pulp manufacturing and so forth. A successive stimulation on the preceding industries has to be enhanced from a technological viewpoint in order to maintain a further development based on novel and innovative technologies. In this regard, energy technology has become and will be increasingly important in a high temperature system so that the basic concept for heat transfer augmentation methods by thermal radiation is reviewed briefly in accord with the recent developments together with theoretical background and the prominent features. The heat transfer augmentation related to thermal radiation is summarized.

1987-01-01

157

Premium performance heating oil - Part 2, Field trial results  

Energy Technology Data Exchange (ETDEWEB)

Limited field trial results of a heating oil additive package developed to minimize unscheduled maintenance indicate that it achieves its goal of keeping heating oil systems cleaner. The multifunctional additive package was developed to provide improved fuel oxidation stability, improved corrosion protection, and dispersency. This combination of performance benefits was chosen because we believed it would retard the formation of sludge, as well as allow sludge already present to be carried through the system without fouling the fuel system components (dispersency should keep sludge particles small so they pass through the filtering system). Since many unscheduled maintenance calls are linked to fouling of the fuel filtering system, the overall goal of this technology is to reduce these maintenance calls. Photographic evidence shows that the ...

1996-07-01

158

Development of a high-performance, coal-fired power generating system with a pyrolysis gas and char-fired high-temperature furnace  

International Nuclear Information System (INIS)

A high-performance power system (HIPPS) is being developed. This system is a coal-fired, combined-cycle plant that will have an efficiency of at least 47 percent, based on the higher heating value of the fuel. The original emissions goal of the project was for NOx and SOx to each be below 0.15 lb/MMBtu. In the Phase 2 RFP this emissions goal was reduced to 0.06 lb/MMBtu. The ultimate goal of HIPPS is to have an all-coal-fueled system, but initial versions of the system are allowed up to 35 percent heat input from natural gas. Foster Wheeler Development Corporation is currently leading a team effort with AlliedSignal, Bechtel, Foster Wheeler Energy Corporation, Research-Cottrell, TRW and Westinghouse. Previous work on the project was also done by General Electric. The HIPPS plant will use a high-Temperature Advanced Furnace (HITAF) to achieve combined-cycle ...

1995-07-12

159

Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel  

International Nuclear Information System (INIS)

In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning measurements on ...

160

Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel  

Energy Technology Data Exchange (ETDEWEB)

In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning measurements on ...

2007-03-15

161

Development of KSTAR heating and current drive systems for long pulse operation  

Energy Technology Data Exchange (ETDEWEB)

The heating and current drive systems are being developed to support long pulse, high {beta}, advanced tokamak fusion physics experiments in the KSTAR tokamak. The heating and current drive systems consisting of neutral beam injection (NBI), ion cyclotron waves (ICRF), lower hybrid waves (LHCD) and electron cyclotron waves (ECH/ECCD) have been designed to operate for pulse lengths up to 300 sec and to provide a range of control functions including current drive and profile control. Development of key technologies for high power, long pulse operation has been on going. Substantial progress has been made on areas such as RF launchers, ion source, and high power supplies.

2003-07-01

162

Development of KSTAR heating and current drive systems for long pulse operation  

International Nuclear Information System (INIS)

The heating and current drive systems are being developed to support long pulse, high #beta#, advanced tokamak fusion physics experiments in the KSTAR tokamak. The heating and current drive systems consisting of neutral beam injection (NBI), ion cyclotron waves (ICRF), lower hybrid waves (LHCD) and electron cyclotron waves (ECH/ECCD) have been designed to operate for pulse lengths up to 300 sec and to provide a range of control functions including current drive and profile control. Development of key technologies for high power, long pulse operation has been on going. Substantial progress has been made on areas such as RF launchers, ion source, and high power supplies.

2003-05-29

163

Potential for hot-dry-rock geothermal resources: experimental results  

Science.gov (United States)

Hot dry rock (HDR) contains insufficient permeability and fluid for natural hydrothermal development, but water pumped in a circulation loop through a HDR reservoir (hydraulically fractured between two drill holes) is being tested and evaluated. The formation of such in situ heat transfer systems, and subsequent testing of the man-made geothermal reservoirs in the Jemez volcanic field, New Mexico have already indicated the technical feasibility of the hot dry rock (HDR) geothermal concept. Documented production history and heat-extraction data obtained during the period from 1978 to 1980 have confirmed heat transfer, low water loss, and predictable thermal drawdown models for the HDR systems. During a nine month test of closed-loop heat extraction operations, 15 x 10/sup 6/ kWh of thermal energy were produced. The effective heat-transfer ...

1982-01-01

164

Integrated numerical modeling of surface-subsurface-coupled, 2-phase fluid/heat flow in limnological system 1. New type of modeling and experimental study; Shizen suirikei no ryutai{center_dot}netsu ido togo moderingu no kokoromi 1. Ryutai{center_dot}netsu ido no atarashii teishikika to jikkenteki kento  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the comprehensive modeling method of fluid and heat flows in the hydrological system. Based upon the concept that the hydrological system is composed of the air-water 2-phase fluids, and the rock phase, various natural processes are modeled including surface/subsurface 2-phase mass transfer, heat exchanges between fluid phases, between fluid and solid phases, and sensible/latent heat exchanges on the ground surface. A field-oriented numerical simulator is developed, in which a set of governing equations is solved for different variables on the surface and in subsurface regions, respectively. Results of an experimental study are presented, in which transient formulation of heat exchange between fluid/solid phases is examined through matching of the observation and calculated performances. (author)

1999-08-31

165

Integrated numerical modeling of surface-subsurface-coupled, 2-phase fluid/heat flow in limnological system 1. New type of modeling and experimental study. Shizen suirikei no ryutai[center dot]netsu ido togo moderingu no kokoromi 1. Ryutai[center dot]netsu ido no atarashii teishikika to jikkenteki kento  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the comprehensive modeling method of fluid and heat flows in the hydrological system. Based upon the concept that the hydrological system is composed of the air-water 2-phase fluids, and the rock phase, various natural processes are modeled including surface/subsurface 2-phase mass transfer, heat exchanges between fluid phases, between fluid and solid phases, and sensible/latent heat exchanges on the ground surface. A field-oriented numerical simulator is developed, in which a set of governing equations is solved for different variables on the surface and in subsurface regions, respectively. Results of an experimental study are presented, in which transient formulation of heat exchange between fluid/solid phases is examined through matching of the observation and calculated performances. (author)

1999-08-31

166

Energy and exergy analysis of a ground source (geothermal) heat pump system  

International Nuclear Information System (INIS)

Ground source heat pumps (GSHPs), often referred to as geothermal heat pumps (GHPs), offer an attractive option for heating and cooling residential and commercial buildings owing to their higher energy efficiency compared with conventional systems. GSHPs have been used for four years in the Turkish market, although they have been in use for more years in developed countries. The purpose of this study is to present an energy and exergy analysis of a GSHP system with a 50 m vertical 1.25 in. nominal diameter U-bend ground heat exchanger. This system was applied to a 65 m"2 room in the Solar Energy Institute, Ege University, Izmir, for the first time at the university level in Turkey. The Institute, built in 1986, has a livable floor area of 3000 m"2 and uses passive solar techniques. The heating and cooling loads of the ...

2004-03-01

167

Thermal performance of automotive aluminium plate radiator  

Energy Technology Data Exchange (ETDEWEB)

The thermal performance of an automotive radiator plays an important role in the performance of an automobile's cooling system and all other associated systems. For a number of years, this component has been given little attention with very little changing in its manufacturing cost, operation and geometry. As opposed to the old tubular heat exchanger configurations used in automotive radiators, plate heat exchangers currently form the backbone of today's process industry with their advanced performance reaching levels the designers of tubular heat exchangers can only dream of. The aluminium roll-bonding technique widely used in manufacturing the cooling compartments for domestic refrigeration units is one of the cheapest methods for heat exchanger manufacturing. Using this technique, it is possible to manufacture a wide range of ...

2005-06-01

168

Inherent safe heat removal in advanced medium-sized high-temperature reactors  

International Nuclear Information System (INIS)

One of the main points for the inherent safety of a pebble bed high temperature reactor (HTR) is to guarantee the safe removal of the after-heat in case of a break-down of all active cooling systems like heat-exchangers or liner-cooling. This will be necessary because it is well known today that graphite pebble bed fuel elements stay intact, if the accident temperature is below 1600 deg. C. Therefore the heat must be taken out of the reactor system by passive, natural law heat-transfer mechanism so that the maximum fuel temperature stays below the specified limit. Today medium-sized HTRs with a power of 750 MW_t_h and more (TGTR-300, HTR 500) reach temperatures of more than 2400 deg. C in small parts of the core in such hypothetical accidents. A possible way to realize the inherent safe heat removal in advanced medium-sized HTRs is to change ...

1990-04-01

169

Scroll compressor for heat pumps in old and new residential buildings; Scroll-Verdichter fuer Waermepumpen zur Wohnraumheizung in Alt- und Neubauten  

Energy Technology Data Exchange (ETDEWEB)

Heat pumps for residential space heating become an increasingly important alternative to the conventional heating system like gas or oil burner. They offer the opportunity to reduce CO{sub 2} emission associated with heating residential homes in Germany. High compressors efficiency and a wide operating map are required so that an economically viable heat pumps is achieved which meets the operational conditions for present and future heating systems. The design parameter of existing heating systems require relatively high condensing temperatures which can be achieved with dedicated compressor designs. The design of Scroll compressors specially adapted to these heat pumps is shown and their operation is explained. (orig.) [German] Waermepumpen fuer die ...

2003-07-01

170

Modeling and analysis of heat transfer from the MHTGR core through a steel reactor vessel to the reactor cavity cooling system  

International Nuclear Information System (INIS)

The commercial Modular High Temperature Gas-Cooled Reactor (MHTGR) achieves improved reactor safety performance and reliability by utilizing an integrated sequence of completely passive thermal storage and heat transfer mechanisms to reject decay heat in the event that all its active cooling systems fail to operate. During such events, the initial heatup transient in the core is followed by a quasi-steady state cooldown process which, if uninterrupted, can continue for several days. A buoyancy-driven natural convection cooling system called the RCCS facilitates the continuous heat removal by circulating ambient air through the reactor cavity, where it is heated and then exhausted to the outside environment. The peak thermal load on the RCCS occurs approximately at the time that the vessel reaches its highest temperature. To confirm the adequacy of the RCCS ...

1994-08-01

171

THERMALLY CONDUCTIVE CEMENTITIOUS GROUTS FOR GEOTHERMAL HEAT PUMPS. PROGRESS REPORT BY 1998  

Energy Technology Data Exchange (ETDEWEB)

Research commenced in FY 97 to determine the suitability of superplasticized cement-sand grouts for backfilling vertical boreholes used with geothermal heat pump (GHP) systems. The overall objectives were to develop, evaluate and demonstrate cementitious grouts that could reduce the required bore length and improve the performance of GHPs. This report summarizes the accomplishments in FY 98.

1998-11-01

172

Radiative Heat Transfer Augmentation in High Temperature Combustion Systems with Application to Radiant Tube Burners. Final Report, April 1987-March 1990.  

Science.gov (United States)

Gas fired radiant tube heaters provide an indirect heating source for applications in which direct contact cannot be permitted between combustion gases and the workpiece. The program was an investigation of ways to improve performance of such burners thro...

1990-01-01

173

Performance of large LWR system codes in calculating the steam-generator heat-transfer behavior  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a series of modeling experiences and problems in simulating the thermal-hydraulic behavior of large PWR steam generators using the RELAP4 and RELAP5 computer codes. Sensitivity studies investigating the heat transfer characteristics of both once-through and U-tube steam generators are discussed. Suggestions and recommendations are given for effective use and potential future improvements of these codes.

1982-01-01

174

Markets for clean energy  

Wastenet

... The products can be categorised as glazed flat-plate collectors, evacuated glass-tube collectors, and unglazed plastic or low temperature collectors. Glazed flat-plate collectors and vacuum tubes are widely used for solar water heating and space heating systems in all types of buildings. Unglazed plastic collectors are used exclusively for lower temperature applications, such as outdoor swimming pools or the agrarian business. Flat-plate solar collectors are likely to ...

175

Investigation on natural convection decay heat removal for the EFR: Status of the program  

International Nuclear Information System (INIS)

The European Research and Development Program on decay heat removal by natural convection for the European Fast Reactor (EFR) covers the calculational methods and the model experiments performed for code validation. The studies concentrate on important physical effects of the cooling modes within the primary system and the direct reactor cooling circuits and include fundamental tests as well as reactor experiments. (author)

1991-11-05

176

High-temperature ceramic receivers  

Energy Technology Data Exchange (ETDEWEB)

An advanced ceramic dome cavity receiver is discussed which heats pressurized gas to temperatures above 1800/sup 0/F (1000/sup 0/C) for use in solar Brayton power systems of the dispersed receiver/dish or central receiver type. Optical, heat transfer, structural, and ceramic material design aspects of the receiver are reported and the development and experimental demonstration of a high-temperature seal between the pressurized gas and the high-temperature silicon carbide dome material is described.

1980-01-01

177

Design concept and testing of an in-bundle gamma densitometer for subchannel void fraction measurements in the THTF electrically heated rod bundle  

International Nuclear Information System (INIS)

A design concept is presented for an in-bundle gamma densitometer system for measurement of subchannel average fluid density and void fraction in rod or tube bundles. This report describes (1) the application of the design concept to the Thermal-Hydraulic Test Facility (THTF) electrically heated rod bundle; and (2) results from tests conducted in the THTF.

178

Corrosion resistant coatings for silicon carbide heat exchanger tubes: Topical report  

Energy Technology Data Exchange (ETDEWEB)

This heat exchanger is a critical step in the development of the Externally Fired Combined Cycle power system, a direct-coal combustion power plant (gas turbine). SiC is the only material with the needed resistance to creep, thermal shock, and oxidation; however a protective coating is needed. Ten candidate materials were identified: alumina-based materials, materials stable with SiO, and low expansion materials. An initial screening study should be performed.

1996-09-01

179

Contribution of surface rayleigh waves to the heat capacity of poly(vinyl chloride)  

British Library Electronic Table of Contents (United Kingdom)

The method of surface acoustic waves is employed to determine the frequency and temperature dependences of the molar heat capacity of poly(vinyl chloride) on the contribution of Rayleigh local components of the longitudinal and transverse vibrations of structural units of the polymer. The calculated and experimental data are compared in terms of their dependence on the relaxation state of the system.

2009-01-01

180

Combined cycles and combined energy systems for a safe and sound environment and life  

Energy Technology Data Exchange (ETDEWEB)

Discussion is presented of world CO{sub 2} emissions and the effect rising population and population distribution has on this. Possible ways of decreasing emissions are presented, including potential for heat recovery, exhaust-air purification as an energy supply, shared power supply in industry, the use of cogeneration, and multiple use of heat in industry. 9 refs., 10 figs., 3 tabs.

1992-01-01

181

A magnetically insulated negative ion source for neutral beam heating  

Energy Technology Data Exchange (ETDEWEB)

A new, magnetically insulated negative ion source has recently been discovered which can produce pulsed negative ion beams (H/sup -/, Li/sup -/, and C/sup -/) with intensities of 100-300 A/cm/sup 2/ at 1-4 MeV. This source may provide the basis for a high energy neutral beam system for heating large tokamaks.

1983-08-01

182

Integrated model of the shallow and deep hydrothermal systems in the East Mesa area, Imperial Valley, California  

Energy Technology Data Exchange (ETDEWEB)

Geological, geophysical, thermal, petrophysical and hydrological data available for the East Mesa hydrothermal system that are pertinent to the construction of a computer model of the natural flow of heat and fluid mass within the system are assembled and correlated. A conceptual model of the full system is developed and a subregion selected for quantitative modeling. By invoking the Boussinesq approximation, valid for describing the natural flow of heat and mass in a liquid hydrothermal system, it is found practical to carry computer simulations far enough in time to ensure that steady-state conditions are obtained. Initial calculations for an axisymmetric model approximating the system demonstrate that the vertical formation permeability of the deep East Mesa system must be very low (k/sub v/ approx. 0.25 to 0.5 md). ...

1982-01-01

183

Morphological features and variations of temperature in the upper thermosphere simulated by a whole atmosphere GCM  

Energy Technology Data Exchange (ETDEWEB)

In order to illustrate morphological features and variations of temperature in the upper thermosphere, we performed numerical simulations with a whole atmosphere general circulation model (GCM) for the solar minimum and geomagnetically quiet conditions in March, June, September, and December. In previous GCMs, tidal effects were imposed at the lower boundaries assuming dominant diurnal and semi-diurnal tidal modes. Since the GCM used in the present study covers all the atmospheric regions, the atmospheric tides with various modes are generated within the GCM. The global temperature distributions obtained from the GCM are in agreement with ones obtained from NRLMSISE-00. In addition, the GCM also represents localised temperature structures which are superimposed on the global day-night distributions. These localised structures, which vary from hour to hour, would be observed as variations with periods of about 2-3 h at a single site. The amplitudes of the 2-3 h variations are ...

2010-07-01

184

Study of dose rates and radionuclides contributing to dose rates in India's 540 MWe pressurised heavy water reactors  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station Unit-3 and 4 (TAPS -3 and 4) are the 540 MWe reactors. Unit-4 attained first criticality on 06th March 2005 and operated for about 230 effective full power days (EFPD). Unit-3 attained first criticality on 21st May 2006 and operated for about 20 EFPD. With the reactor operation radiation field increases on the Primary Heat Transport system equipments, Moderator system equipments and auxiliary system equipments due to deposition of fission products and activation products in different reactor systems. These dose rates significantly contributes to the external exposure and stations collective dose during reactor operation, refueling operation and maintenance activities. A study was undertaken at TAPS 3 and 4 to identify the system equipments showing the significant dose rates and identify the radionuclides present in the primary ...

2006-11-13

185

User's manual for the BNW-I optimization code for dry-cooled power plants. [MFCIRI Code  

Science.gov (United States)

This appendix provides a listing of the BNW-I optimization code, MFCIRI, for a metal finned tube dry-cooled heat rejection system for power plants. (LCL)

1977-01-01

186

Turbine air intake treatment  

Energy Technology Data Exchange (ETDEWEB)

Gas turbine component protection remains essential but environmental regulations emphasize the gas-turbine efficiency. Heating and cooling are features often integrated into the GI air intake packages to provide the optimum operating conditions. This paper describes modern inlet air treatment systems and discusses their effectiveness. (author)

1999-07-01

187

System Analysis for Decay Heat Removal in Lead-Bismuth Cooled Natural Circulated Reactors  

Science.gov (United States)

Decay heat removal analyses for lead-bismuth cooled natural circulation reactors are described in this paper. A combined multi-dimensional plant dynamics code (MSG-COPD) has been developed to conduct the system analysis for the natural circulation reactors. For the preliminary study, transient analysis has been performed for a 100 MWe lead-bismuth-cooled reactor designed by Argonne National Laboratory (ANL). In addition, decay heat removal characteristics of a 400 MWe lead-bismuth-cooled natural circulation reactor designed by Japan Nuclear Cycle Development Institute (JNC) has been evaluated by using MSG-COPD. PRACS (Primary Reactor Auxiliary Cooling System) is prepared for the JNC's concept to get sufficient heat removal capacity. During 2000 sec after the transient, the outlet temperature shows increasing tendency up to the maximum temperature of 430 Centigrade, because ...

2002-07-01

188

Northward Market Extension for Passive Solar Water Heaters by Using Pipe Freeze Protection with Freeze-Tolerant Piping: Preprint  

Energy Technology Data Exchange (ETDEWEB)

Conference paper regarding research in freeze-protection methods that could extend market acceptance for passive solar domestic water heating systems in more northern climates if the U.S.

2006-05-01

189

Environmental effects and energy efficiency in building design: A green building approach. Part 1, energy efficiency techniques. Research report  

Energy Technology Data Exchange (ETDEWEB)

;Contents: Energy Use; Building Fabric Performance; Ventilation and Infiltration; Passive Solar Design; Heating Systems and Controls; Hot and Cold Water Provision; and Lighting and Electrical Appliances.

1993-01-01

190

Environmental Effects and Energy Efficiency in Building Design: A Green Building Approach. Part 1, Energy Efficiency Techniques.  

Science.gov (United States)

Contents: Energy Use; Building Fabric Performance; Ventilation and Infiltration; Passive Solar Design; Heating Systems and Controls; Hot and Cold Water Provision; and Lighting and Electrical Appliances.

1993-01-01

191

Electric cars and the electricity system  

Energy Technology Data Exchange (ETDEWEB)

The electric power consumption of electric cars and the demand they will pose on electric utilities are considered. The increased amount of travel will require more electric power in summer, while space heating makes larger demands in winter. This leads to nearly flat demand on electric utilities throughout the year. 5 refs.

1981-01-01

192

Design of the heat receiver for the U.S./Russia solar dynamic power joint flight demonstration  

Energy Technology Data Exchange (ETDEWEB)

A joint US/Russia program is being conducted to develop, fabricate, launch, and operate a solar dynamic demonstration system on Space Station Mir. The goal of the program is to demonstrate and confirm that solar dynamic power systems are viable for future space applications such as the International Space Station Alpha. The major components of the system include a heat receiver, a closed Brayton cycle power conversion unit, a power conditioning and control unit, a concentrator, a radiator, a thermal control system, and a Space Shuttle carrier. This paper discusses the design of the heat receiver component. The receiver comprises a cylindrical cavity, the walls of which are lined with a series of tubes running the length of the cavity. The engine working fluid, a mixture of xenon and helium, is heated by the concentrated sunlight incident on ...

1995-12-31

193

Thermal performance simulation of a solar cavity receiver under windy conditions  

British Library Electronic Table of Contents (United Kingdom)

Solar cavity receiver plays a dominant role in the light-heat conversion. Its performance can directly affect the efficiency of the whole power generation system. A combined calculation method for evaluating the thermal performance of the solar cavity receiver is raised in this paper. This method couples the Monte-Carlo method, the correlations of the flow boiling heat transfer, and the calculation of air flow field. And this method can ultimately figure out the surface heat flux inside the cavity, the wall temperature of the boiling tubes, and the heat loss of the solar receiver with an iterative solution. With this method, the thermal performance of a solar cavity receiver, a saturated steam receiver, is simulated under different wind environments. The highest wall temperature of the boi...

2011-01-01

194

Small heat pumps using ammonia, phase 3; Kleinwaermepumpe mit Ammoniak, Phase 3: Fluegelzellenverdichter mit Economizer und Schraubenverdichter  

Energy Technology Data Exchange (ETDEWEB)

This comprehensive final report for the Swiss Federal Office of Energy (SFOE) presents the results of research done in the third phase of a research project that investigated components for small heat pump systems that use ammonia as a working fluid. The report includes a summary of the findings of the first two phases of the project and goes on to describe tests done with rotary vane and scroll compressors. The aims of the project are discussed and the work done is listed chronologically. The construction and the components of the test installation are described in detail. Also, the heat pump testing facilities at the University of Applied Science in Rapperswil, Switzerland, are described. The results of the measurements made for various temperature gradients are presented in detail and commented on; also, the various types of compressor tested and other heat pump compressors are compared.

2003-07-01

195

Heat and mass transfer analogy studies of binary liquid mixture in comparison with ethanol-n-heptane evaporating to air  

Energy Technology Data Exchange (ETDEWEB)

An experimental and theoretical study of heat and mass transfer analogy and a comparison of that to a binary liquid mixture evaporation is presented. Common organic solvents, ethanol and n-heptane, were used to form an alcohol - hydrocarbon mixture. Studies were carried out in a horizontal rectangular channel having air flow velocities of 0.2 - 0.9 m/s. Heat transfer coefficients were measured with a copper plate resistor and mass transfer coefficients with a square pool. The heat and mass transfer analogy is presented for a system having two evaporating compounds with a fixed value of air flow and verified by measuring and comparing mass transfer coefficients for distilled water with air flow velocities of 0.2 - 0.9 m/s. An illustrative example of the use of the theory for industrial ventilation is presented. (author)

1995-12-31

196

Flow field and heat transfer associated with laminar flow over a forward-facing step  

Science.gov (United States)

The flow and heat transfers associated with a plane laminar flow past a forward-facing step were analyzed using a power-law numerical scheme combined with a false vorticity-stream function approach. To improve the traditional wall-vorticity boundary condition, a novel method, based on an accurate description of the nonslip wall condition, was developed and utilized. The convergence for a 56 x 49 grid system was obtained in about 350 iterations. The computed reattachment distances in the upper separated region agree with the available experimental data for a blunt plate. The heat transfer augmentation is significant across the step; however, it is counterbalanced by the deterioration of heat transfer immediately upstream of the step.

1986-01-01

197

Coupling of geothermal heat pumps with thermal solar collectors  

Energy Technology Data Exchange (ETDEWEB)

The study discussed relates to the design and development of a process consisting of combining a reversible geothermal heat pump with thermal solar collectors for building heating and cooling and the production of domestic hot water. The proposed process, called GEOSOL, has been installed in a 180 m{sup 2} private residence in 2004. This installation is the subject of long-term experimental follow-up to analyse the energy-related behavior of the installation at all times of the year. In addition, different configurations of this combined system (geothermal heat pump and thermal solar collectors) have been defined and will be simulated numerically using TRNSYS software. A comparative analysis of these different alternative versions will be conducted to determine the best configuration(s) of the GEOSOL process in terms of energy, economical and environmental performances. (author)

2007-07-15

198

Tehachapi solar thermal system first annual report  

Energy Technology Data Exchange (ETDEWEB)

The staff of the Southwest Technology Development Institute (SWTDI), in conjunction with the staff of Industrial Solar Technology (IST), have analyzed the performance, operation, and maintenance of a large solar process heat system in use at the 5,000 inmate California Correctional Institution (CCI) in Tehachapi, CA. This report summarizes the key design features of the solar plant, its construction and maintenance histories through the end of 1991, and the performance data collected at the plant by a dedicated on-site data acquisition system (DAS).

1993-05-01

199

System behavior after a loss of electric power in HANARO  

International Nuclear Information System (INIS)

A LOss of Electric Power(LOEP) experiment was conducted after a 30MW full power operation as one of the reactor performance tests to verify the design characteristics of the HANARO. The objective of LOEP test was to investigate the integral behaviors of the system and the components as well as the cooling characteristics when the electric power was lost unexpectedly. Through the test, it was confirmed that the residual heat from the core was safely removed by the natural convection cooling and the assistant power systems operated normally

2005-04-11

200

Lamp system for uniform semiconductor wafer heating  

Energy Technology Data Exchange (ETDEWEB)

A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.

2001-01-01

201

Development of solar agricultural dryers combined with PV modules and solar collectors  

Energy Technology Data Exchange (ETDEWEB)

The intention of the research carried out was to develop photovoltaic driven solar heating systems applied for drying of medicinal plants in remote areas. Identification of hybrid photovoltaic - photothermal systems was done and discussion of technical features and applicability of such systems in agriculture is presented. Detail technical specification of PV powered medicinal plants solar dryer and cost effectiveness parameters are given. Operational and economic results obtained during testing of the dryer are promising. (orig.) 4 refs.

1997-12-31

202

Development of High-Efficiency Low-Lift Vapor Compression System - Final Report  

Energy Technology Data Exchange (ETDEWEB)

PNNL, with cofunding from the Bonneville Power Administration (BPA) and Building Technologies Program, conducted a research and development activity targeted at addressing the energy efficiency goals targeted in the BPA roadmap. PNNL investigated an integrated heating, ventilation and air conditioning (HVAC) system option referred to as the low-lift cooling system that potentially offers an increase in HVAC energy performance relative to ASHRAE Standard 90.1-2004.

2010-03-31

203

Design, fabrication, qualification and reliability of the major components of ''MONJU'' from a safety point of view  

International Nuclear Information System (INIS)

This paper will review code and standard and the safety related features of major components of Monju: Components of the Reactor Coolant Boundary; Components of the Reactor Shurdown Systems; Components of the Decay Heat Removal Systems; Components of the Engineered Safety Features; Other Safety Related Components. Their relationship to the system or plant function is emphasized, in reviewing these components.

1982-07-01

204

Proper use of sludge-control additives in residential heating oil systems  

Energy Technology Data Exchange (ETDEWEB)

Discussed are various aspects of heating oil `sludge`: How it forms, typical problems it causes, how sludge-control additives work, what should be expected of them, and what happens in a contaminated system when such additives are used. Test results from laboratory and field experiments demonstrate that performance of commercially available additives varies greatly. The concept of `end-of-the-line` treatment is described and compared with bulk fuel treatment. A procedure is described whereby a retailer can test additives himself, and thus determine just what those additives will or will not do for his business. Finally, the economics of an effective treatment program are outlined.

1995-04-01

205

Energy options and employment  

International Nuclear Information System (INIS)

Decision making about possible investment options for energy supply technology is usually based on economic criteria reflecting primarily the unit cost of energy and the return on capital invested. This study attempts to reverse the process. The chosen starting point is a UK investment programme geared towards reliance on conservation, renewable energy systems and the more efficient use of our remaining fossil fuels (through combined heat and power and district heating systems). The number and type of jobs likely to be created is then estimated and compared with the jobs likely to be created by the currently proposed nuclear power programme. (author).

206

Development of a high current negative ion source for fusion application  

Energy Technology Data Exchange (ETDEWEB)

Negative ion based neutral beam injector is one of the most attractive heating system in future fusion reactors. In realizing the system, the crucial device which has to be developed is a high intensity negative ion source. Significant progress has been made on the negative ion source in these years. Among them, a few ampere negative ion beam were produced stably, while the divergence of negative ion beams becomes to be as low as < 10 mrad. We consider these results are demonstrating the potential of the negative ion source for the heating device in future reactors.

1988-11-01

207

Use of a temperature-initiated passive cooling system (TIPACS) for the modular high-temperature gas-cooled reactor cavity cooling system (RCCS)  

Energy Technology Data Exchange (ETDEWEB)

A new type of passive cooling system has been invented (Forsberg 1993): the Temperature-Initiated Passive Cooling System (TIPACS). The characteristics of the TIPACS potentially match requirements for an improved reactor-cavity-cooling system (RCCS) for the modular high-temperature gas-cooled reactor (MHTGR). This report is an initial evaluation of the TIPACS for the MHTGR with a Rankines (steam) power conversion cycle. Limited evaluations were made of applying the TIPACS to MHTGRs with reactor pressure vessel temperatures up to 450 C. These temperatures may occur in designs of Brayton cycle (gas turbine) and process heat MHTGRs. The report is structured as follows. Section 2 describes the containment cooling issues associated with the MHTGR and the requirements for such a cooling system. Section 3 describes TIPACS in nonmathematical terms. Section 4 describes TIPACS`s ...

1994-04-01

208

Evaluation of static thermophysical properties of the ternary molten salt system Li, Na and Be/F based on the modified Peng-Robinson equation  

International Nuclear Information System (INIS)

The static thermophysical properties of the molten salt system like LiF-NaF-BeF_2 influence the design and construction of the fuel salt and coolant in the Molten Salt Reactor for the new generation. In this paper, the equation of state of the ternary system 0.15LiF-0.58NaF-0.27BeF_2, over the temperature range from 873.15K to 1073.15K at one atmosphere pressure, is described by using modified Peng-Robinson equation. The density of the ternary system is evaluated by this equation directly, and compared with the experimental data. Base on the equation of state, the other static thermophysical properties such as the enthalpy, entropy and heat capacity at constant pressure are evaluated by the fugacity coefficient and residual function methods respectively. The density calculated by Peng-Robinson equation is in highly agreement with the experimental data, and the enthalpy, entropy and ...

2008-03-01

209

Evaluation of static thermodynamic properties of the ternary molten salt system Li,Na,Be/F, based on the modified Peng-Robinson equation  

International Nuclear Information System (INIS)

The static thermodynamic properties of the molten salt system like LiF-NaF-BeF_2 influence the design and construction of the fuel salt and coolant in the Molten Salt Reactor for the new generation. In this paper, the equation of state of the ternary system 15%LiF-58%NaF-27%BeF_2, over the temperature range of 873.15K to 1073.15K at one atmosphere pressure, is described using Peng-Robinson equation modified by us. And the density of the ternary system is evaluated by this equation directly, and compared with the experimental data. Base on the equation of state, the other static thermodynamic properties such as the enthalpy, entropy and heat capacity at constant pressure are estimated by the residual function method and the fugacity coefficient method respectively. The density calculated by Peng-Robinson equation is in highly agreement with the experimental data, and the enthalpy, entropy and ...

2007-04-22

210

Evaluation of Static Thermophysical Properties of the Ternary Molten Salt System Li, Na and Be/F Based on the Modified Peng-Robinson Equation  

Science.gov (United States)

The static thermophysical properties of the molten salt system like LiF-NaF-BeF2 influence the design and construction of the fuel salt and coolant in the Molten Salt Reactor for the new generation. In this paper, the equation of state of the ternary system 0.15LiF-0.58NaF-0.27BeF2, over the temperature range from 873.15K to 1073.15K at one atmosphere pressure, is described by using modified Peng-Robinson equation. The density of the ternary system is evaluated by this equation directly, and compared with the experimental data. Base on the equation of state, the other static thermophysical properties such as the enthalpy, entropy and heat capacity at constant pressure are evaluated by the fugacity coefficient and residual function methods respectively. The density calculated by Peng-Robinson equation is in highly agreement with the experimental data, and the enthalpy, entropy and ...

2008-01-01

211

Cheng cycle cogeneration system; Cheng cycle system cogeneration setsubi  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the Cheng cycle system featured by variable heating/generation ratio for effective operation of cogeneration systems (CGS). In this system, a superheater and reheating burner are added to an exhaust heat recovery (EHR) boiler for conventional gas turbine CGSs, while additional injection steam piping is attached to a gas turbine. Steam is injected through manifolds mounted on the periphery of a combustion chamber, and hot gas mixture of steam and air in a combustion chamber is expanded in a turbine and converted to motive power. This technology thus can improve efficiency and output power, and can operate variably CGSs corresponding to heating and generation demands. This technology has been promoted by introducing the technology of middle class Cheng cycle CGS with 4MW class gas turbine from IPT Co., U.S.A. The first ...

1996-03-29

212

Numerical heat transfer studies of PCMs used in a box-type solar cooker  

Energy Technology Data Exchange (ETDEWEB)

Theoretical investigations on the phase change materials (PCMs) used as the heat storage media for box-type solar cookers have been conducted in this study. The selected PCMs are magnesium nitrate hexahydrate, stearic acid, acetamide, acetanilide and erythritol. For a two-dimensional simulation model based on the enthalpy approach, calculations have been made for the melt fraction with conduction only. Different materials such as glass, stainless steel, tin, aluminum mixed, aluminum and copper are used as the heat exchanger container materials in the numerical calculations. The large value of thermal conductivity of heat exchanger container material did not make a significant contribution on the melt fraction except for at very low thermal conductivities. Based on the theoretical results, stearic acid and acetamide are found to be good compatibility with latent heat storage system. ...

2008-05-15

213

Isolation condenser passive cooling of a nuclear reactor containment  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a nuclear system comprising a containment airspace in which a nuclear reactor pressure vessel is disposed there being a reactor core within the pressure vessel. It comprises a heat exchanger elevated a distance above the pressure vessel; a pool of water surrounding the heat exchanger; means for venting the pool of water to an environment outside the containment; a heat exchanger entry conduit within the containment, the entry conduit having an open lower end communicating with the containment space, and an upper end connected to the heat exchanger, water-containing heated fluid present in the containment airspace incident a pressure vessel loss of coolant event entering and flowing through the entry conduit into the heat exchanger for cooling the fluid to convert water vapor therein to a condensate and separate ...

1991-10-22

214

Indirect heating of natural gas using vapor chambers; Aquecimento indireto de gas natural com uso de camaras de vapor  

Energy Technology Data Exchange (ETDEWEB)

Operation safety and reliability are major guidelines in the design of city-gate units. Conventional natural gas heaters operate by a indirect mechanism, where liquid water is used to transfer heat by natural convection between the combustion chamber and the natural gas coil. In this work, the concept of vapor chamber is evaluated as an indirect gas heater. In a vapor chamber, liquid water is in contact with the heat source, and vaporizes. The vapor condenses in contact with the heat sink. A reduced scale model was built and tested in order to compare these two heating concepts where the combustion chamber was replaced by electrical cartridge heaters. This engineering model can operate either as a conventional heater or as a vapor chamber. The comparison between the concepts was done by inducing a controlled power to the cartridges and by measuring the resulting temperature distributions. In the novel ...

2005-07-01

215

Geothermal Heat Pump research and development studies at Sandia National Laboratories  

Energy Technology Data Exchange (ETDEWEB)

The Geothermal Heat Pump (GHP) concept was originally developed in the 1940`s. Recently, because of increasing energy costs, utility interest, and the development of simple and durable ground source heat exchangers, GHP`s have gained international attention as a proven means of energy conservation and electrical peak power demand reduction. GHP systems require installation of a buried heat exchanger to utilize the nearly constant ground temperature making them more efficient than conventional air source heat pumps. However, the high installation cost for both residential and commercial applications is a major obstacle to their market penetration. Sandia National Laboratories (SNL) through its sponsors, the Department of Energy (DOE), and the Department of Defense (DOD), has embarked on a research program to find ways to reduce GHP installation costs and improve performance, thereby ...

1994-08-01

216

Final phase testing and evaluation of the 500 kW direct contact pilot plant at East Mesa  

Energy Technology Data Exchange (ETDEWEB)

The testing performed during the last phase of the geothermal direct contact heat exchanger program utilizing the 500 kW pilot plant provided more insight into the capabilities and limits of the direct contact approach and showed that more work needs to be done to understand the inner workings of a large direct contact heat exchanger if they are to be modeled analytically. Testing of the column demonstrated that the performance was excellent and that the sizing criteria is conservative. The system operated smoothly and was readily controlled over a wide range of operating conditions. Performance evaluation showed pinch differentials of 4/sup 0/F or less and better than predicted heat transfer capability. Testing during this final phase was directed towards establishing the limits of the column to transfer heat. The working column height was shortened progressively to approximately ...

1983-12-01

217

Effect on heat-transfer augmentation by channel width in a sinusoidal wave channel  

Energy Technology Data Exchange (ETDEWEB)

In the development of high performance heat transfer surface on a compact heat exchanger, it was clarified that how reattachment point heat transfer and fluid flow are affected by channel width, at the same time, an evaluation of heat transfer performance and an investigation of optimum channel width were carried out. The channel system used in the experiment is as follows; (1) blow-off type with rectangular section channel, (2) span length of 200 mm, (3) wave length (pitch) of 80 mm, and (4) channel length of 12.5 wave length. The channel Reynolds number was set at about 10/sup 4/ which is relatively higher than the current studies. The results of the experiment were summarized as follows. (1) The channel width H has relevance to the phase difference between the fluid flow in cone portion of main stream and wave shape, the flow patterns are divided roughly into three types. These ...

1988-06-25

218

Study of radionuclide contributing to dose rates in 540 MWe plant environment  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station Unit-4 is first 540 MWe pressurized heavy water reactor in India. It achieved criticality on 06th March 2005 and then operated at full power i.e 500 MWe. Radiation workers during the normal operation and reactor shutdown are exposed to radiation field. The control of dose rates and the collective dose of the radiation workers is most important for the best performance of the reactor. Experience gained during the operation of the 220 MWe reactors has shown that the Moderator system, primary heat transport system, annulus gas system and moderator cover gas system are the main systems contributing to the dose rate and collective dose. In order to identify the radio nuclides contributing to the radiation field, study was undertaken at TAPS Unit-4. Various samples from the Moderator, primary heat transport ...

2005-11-23

219

3D-nuclear heat generation in PCC-charcoal filter in TAPP-3 and 4  

International Nuclear Information System (INIS)

This paper deals with the calculations of 3D nuclear heat generation profile in the charcoal filter and subsequently the commencement time of Primary Containment Cleanup (PCC) system of 540MWe Pressurized Heavy Water Reactor (PHWR). Fuel failure is predicted due to overheating of the fuel under loss of Coolant Accident (LOCA) without Emergency Core Cooling System (LOCA without ECCS). Subsequently fission product gasses along with water vapours are released to Reactor Building (RB) atmosphere. Plate-out and water trapping mechanism stabilizes the concentration of significant fission products i.e. radioiodines in about 4 hours before being circulated through charcoal filters of Containment Cleanup system. After cleaning up the RB atmosphere, it is discharged to outside atmosphere through stack. The isotopes of radioiodine emit beta and gamma radiations. Gamma radiations are partly stopped within the ...

2006-11-13

220

Theoretical and basic experimental analysis on load adjustment of geothermal heat pump systems  

Energy Technology Data Exchange (ETDEWEB)

In order to match the output capacity of a geothermal heat pump system (GHPS) with the actual load requirement, research has been conducted in searching for suitable adjusting methods for the GHPS and on the subsequent effects on the working parameters of the GHPS. Firstly, several methods are compared, and it is found that the method of adjusting the compressor's rotation speed using a transducer is better than the others. Secondly, this method is experimented on a small scale GHPS at frequencies ranging from 30 to 55 Hz. The analysis of the experimental data reveals the relationships between the compressor frequency and other important parameters, such as coefficient of performance, heat capacity, cool capacity and compressor power input. The conclusions in the paper can serve as some guidance to the load adjustment of GHPS. (Author)

2003-01-01

221

The importance of axial effects for borehole design of geothermal heat-pump systems  

Energy Technology Data Exchange (ETDEWEB)

This paper studies the effects of axial heat conduction in boreholes used in geothermal heat pump systems. The axial effects are examined by comparing the results obtained using the finite and infinite line source methods. Using various practical design problems, it is shown that axial effects are relatively important. Unsurprisingly, short boreholes and unbalanced yearly ground loads lead to stronger axial effects. In one example considered, it is shown that the borehole length is 15% shorter when axial conduction effects are considered. In another example dealing with underground water freezing, the amount of energy that has to be removed to freeze the ground is three times higher when axial effects are considered. (author)

2010-04-15

222

Model-based automation system for demand-based heating and ventilation; Modellgestuetztes Mess- und Automatisierungssystem zur bedarfsgerechten Heizung und Lueftung  

Energy Technology Data Exchange (ETDEWEB)

Better quality of thermal comfort as well as reduced heat energy demand and accordingly CO{sub 2} emission can be achieved by better heating and ventilation strategies in private buildings. The paper deals with a novel model-based measurement and automation system. It describes the implementation of better strategies under given technical circumstances. (orig.) [German] Durch Verbesserung der Heizungs- und Lueftungsstrategien im privaten Lebensbereich kann sowohl Heizenergie eingespart und damit die CO{sub 2}-Emission verringert, als auch die Raumbehaglichkeit verbessert werden. Der Beitrag behandelt ein modellgestuetztes Mess- und Automatisierungssystem, mit dem die Realisierung der verbesserten Strategien unter gegebenen technischen Randbedingungen praktisch erst moeglich wird. (orig.)

2003-04-01

223

Influence of two systematic parameters on the geothermal heat pump system operation  

Energy Technology Data Exchange (ETDEWEB)

In order to match the output capacity of a geothermal heat pump system (GHPS) with the actual load requirement, research has been carried out in finding the influence of two systematic parameters, the water flow rate inside the condenser and the compressor input frequency on the GHPS operation. Experiments are done on a small-scale GHPS at the water flow rate ranging from 0.054 kg/s to 0.174 kg/s and the frequency from 30 Hz to 55 Hz. The analysis of the experimental data reveals the relationships among the compressor frequency, the water flow rate and other important parameters such as coefficient of performance (COP), heat capacity and compressor power input. The conclusions in the paper can serve as some guidance to the load adjustment of GHPS. (author)

2003-01-01

224

Experimental assessment of energy storage via variable speed compressor  

British Library Electronic Table of Contents (United Kingdom)

In this study, usage of a variable speed refrigeration system in latent heat thermal energy storage (LHTES) system is investigated to increase energy storage efficiency. Four different compressor speed control cases are compared to obtain a constant heat transfer fluid (HTF) temperature at the inlet of the energy storage tank. These control cases are (i) control with evaporation temperature, (ii) control with ethylene glycol temperature at the outlet section of evaporator, (iii) control with suction pressure of the compressor and (iv) on/off control. By means of the experimental analysis the best control strategy is obtained as control with Case (ii), in terms of stability of inlet temperature of heat transfer fluid, variations of energy efficiency of LHTES and coefficient of performance (...

2011-01-01

225

Lauric and palmitic acids eutectic mixture as latent heat storage material for low temperature heating applications  

Energy Technology Data Exchange (ETDEWEB)

Palmitic acid (PA, 59.8 {sup o}C) and lauric acid (LA, 42.6 {sup o}C) are phase change materials (PCM) having quite high melting temperatures which can limit their use in low temperature solar applications such as solar space heating and greenhouse heating. However, their melting temperatures can be tailored to appropriate value by preparing a eutectic mixture of the lauric and the palmitic acids. In the present study, the thermal analysis based on differential scanning calorimetry (DSC) technique shows that the mixture of 69.0 wt% LA and 31 wt% PA forms a eutectic mixture having melting temperature of 35.2 {sup o}C and the latent heat of fusion of 166.3 J g{sup -1}. This study also considers the experimental determination of the thermal characteristics of the eutectic mixture during the heat charging and discharging processes. Radial and axial temperature distribution, heat ...

2005-04-01

226

Thermo-economic analysis of solar powered adsorption heat pump  

British Library Electronic Table of Contents (United Kingdom)

The economic feasibility of the residential solar thermal (ST) cooling system designed in the companion article [1] is ascertained by comparing it with a solar electric (SE) cooling system, and also with the baseline (i.e., control case), a grid dependent, highest efficiency COPC=5.66 heat pump. The economic scenario is analyzed for 24 cities across the southern USA, south of the 37degreeN. The SE cooling system provides lifecycle (20 year) savings to the homeowner only where electric rates are high and it is heavily subsidized. The overall societal effect (sum of taxpayer funded rebate and homeowner savings) is actually an increased cost everywhere except the California Central Valley, where the net savings is $1500. In the same valley, The ST cooling system provides greater lifecycle sav...

2007-01-01

227

High efficiency chemical energy conversion system based on a methane catalytic decomposition reaction and two fuel cells. Part II. Exergy analysis  

Energy Technology Data Exchange (ETDEWEB)

A methane catalytic decomposition reactor-direct carbon fuel cell-internal reforming solid oxide fuel cell (MCDR-DCFC-IRSOFC) energy system is highly efficient for converting the chemical energy of methane into electrical energy. A gas turbine cycle is also used to output more power from the thermal energy generated in the IRSOFC. In part I of this work, models of the fuel cells and the system are proposed and validated. In this part, exergy conservation analysis is carried out based on the developed electrochemical and thermodynamic models. The ratio of the exergy destruction of each unit is examined. The results show that the electrical exergy efficiency of 68.24% is achieved with the system. The possibility of further recovery of the waste heat is discussed and the combined power-heat exergy efficiency is over 80%. (author)

2010-10-01

228

High efficiency chemical energy conversion system based on a methane catalytic decomposition reaction and two fuel cells. Part II. Exergy analysis  

British Library Electronic Table of Contents (United Kingdom)

A methane catalytic decomposition reactor-direct carbon fuel cell-internal reforming solid oxide fuel cell (MCDR-DCFC-IRSOFC) energy system is highly efficient for converting the chemical energy of methane into electrical energy. A gas turbine cycle is also used to output more power from the thermal energy generated in the IRSOFC. In part I of this work, models of the fuel cells and the system are proposed and validated. In this part, exergy conservation analysis is carried out based on the developed electrochemical and thermodynamic models. The ratio of the exergy destruction of each unit is examined. The results show that the electrical exergy efficiency of 68.24% is achieved with the system. The possibility of further recovery of the waste heat is discussed and the combined power-heat e...

2010-01-01

229

A miniaturized spatial temperature gradient capillary electrophoresis system with radiative heating and automated sample introduction for DNA mutation detection  

British Library Electronic Table of Contents (United Kingdom)

Abstract A miniaturized spatial temperature gradient CE system with automated sample introduction for DNA mutation detection was established. Continuous electrokinetic sample injection was achieved by combining an automated slotted vial array sample introduction device to the spatial temperature gradient CE system. The temperature gradient was produced by a radiative heating system with a single graphite block heater, and the stability of the temperature gradient was investigated. The temperature variation of each measure point was 0.12 0.21% RSD (n=7) within 6 h. A 14 cm Teflon AF coated silica capillary was used both as the separation channel and as the liquid core waveguide tube of fluorescence signal. Under a temperature gradient from 54.8 to 59.5 C, a low range control mutation standa...

2010-01-01

230

Two-fluid modeling of condensation in the presence of noncondensables in two-phase channel flows  

Energy Technology Data Exchange (ETDEWEB)

Condensing two-phase channel flow occurs in many industrial applications, including heating and refrigeration systems. It can also occur in certain nuclear reactor accidents. For example, during a small-break loss-of-coolant accident in a pressurized water reactor, following the partial depletion of the primary coolant, condensation of steam on the primary side of the steam generator tubes can provide a heat sink for disposal of the decay heat generated in the reactor core. Condensing two-phase flow can also play an important role in the operation of the passive emergency cooling system in the advanced simplified boiling water reactor. Here, steady-state condensation in the presence of a noncondensable in a concurrent two-phase channel flow is analyzed using a two-fluid model. The effect of noncondensables on the combined heat transfer at the liquid-gas mixture ...

1995-01-01

231

Refrigeration loads in a freezer due to hot gas defrost and their associated costs  

Energy Technology Data Exchange (ETDEWEB)

The build-up of frost on unit cooler surfaces, if not periodically cleared, will eventually cause impairment of the unit's performance, eventually rendering it useless. Thus it is necessary, in spaces below freezing, to provide an external supply of heat to warm the unit sufficiently to melt the frost and remove it. In large central-plant-type systems the most common method employed for supplying heat is from the high-pressure side of the refrigeration system, referred to as hot gas defrost. Although the heat thus captured for use in melting frost would otherwise be rejected external to the system, the defrosting process is not free of cost. There are significant losses associated with the process the magnitude of which have not heretofore been fully identified. This paper looks at the heat and mass transfer and fluid flow ...

1989-01-01

232

CATHENA simulation of the WOLSUNG D_20 spill incident of 1984 November 25  

International Nuclear Information System (INIS)

The CATHENA (formerly ATHENA) has been used to simulate the thermalhydraulic behaviour of the WOLSUNG-1 CANDU-600 reactor during the D_20 spill incident of 1984 November 25. A 4-inch (nominal) Liquid Relief Valve inadvertently opened in the reactor auxiliary system during normal reactor operation, resulting in a discharge of heavy water from the primary heat transport system. The valve remained open for approximately 29 minutes. CATHENA is an advanced thermalhydraulic computer code for analysis of postulated loss-of-coolant accidents (LOCA) and transient faults in CANDU nuclear reactors. A full two-fluid (six-equation) representation of the two-phase flow is used. Component models are used to represent pumps, valves, critical discharge, etc., which are necessary to describe the behaviour of the CANDU system under upset conditions. Heat transfer between the fluid and piping walls (or ...

1986-06-09

233

The effect of heat transfer augmentation on two-phase flow instabilities in a vertical boiling channel  

International Nuclear Information System (INIS)

Experimental and theoretical work have been carried out to find out the effects of heat transfer augmentation on two-phase flow instabilities in a single channel system. The effect of mass flow rate, heat input and inlet subcooling on the system behavior is studied using Freon-11 as the test fluid and six different heater surfaces are tested at various experimental conditions. Experimental evaluation is done using the steady-state pressure drop versus mass flow rate curves along with the curves of additional inlet pressure drop required to stabilize the system during the oscillations, and tables generated using the experimental data. Homogeneous equilibrium flow model and finite differences are used in theoretical analysis. An empirical relationship is obtained to calculate the pressure drop across the exit restriction. Characteristic equation for the system is ...

1985-11-01

234

Solar expriment begins at Atlanta school. [George A. Towns Elementary School  

Science.gov (United States)

The largest solar heating and cooling system undertaken to date is now operating at the George A. Towns Elementary School in Atlanta, Georgia. It is expected to provide more than 60 percent of the building's heating and cooling requirements, using commercially available components and techniques. The Towns project is a United States Energy Research and Development Administration-sponsored experiment. The principal components of the solar heating and cooling system designed for the school--the solar collector array, the existing gas-fired boiler, the absorption chiller, and hot and cold water underground tanks to provide thermal storage--are described. To derive maximum benefit from the experiment, the system is fully instrumented for accurate measurement of performance. Environmental data, including insolation and ambient temperture, humidity, and wind ...

1976-03-01

235

Leak-before-break strategy for CANDU primary piping systems  

Energy Technology Data Exchange (ETDEWEB)

Recent advances in elastic-plastic fracture mechanics have made it possible to assess the stability of cracks in ductile piping systems. These technological developments have been used by Ontario Hydro as the nucleus of an approach for demonstrating that CANDU primary heat transport piping systems will not break catastrophically; at worst they would leak at a detectable rate. This leak-before-break approach has been taken on the Darlington nuclear generating station as a design stage alternative to the provision of pipe whip restraints on large diameter, primary heat transport system piping. Positive conclusions reached via this approach are considered sufficient to exclude the requirement to provide protective devices, such as pipe whip restraints. In arriving at the proposed leak-before-break approach a review of current and proposed leak-before-break licensing positions of other ...

1986-01-01

236

Heat transfer augmentation for external ice-on-tube TES systems using porous copper mesh to increase volumetric ice production  

Energy Technology Data Exchange (ETDEWEB)

Substantial thermal performance improvement in ice-on-tube cold thermal energy storage systems (TES) is possible by making use of porous copper mesh as a Heat Conducting Enhancement Device (HCED). HCEDs are inexpensive heat transfer augmentation devices that can result in faster rate of ice growth and larger final steady state ice build volume by reducing the controlling thermal conduction resistance of the ice layer. This improves the competitiveness of external ice-on-tube systems as compared to other TES systems, such as dynamic ice harvesters and static internal melt systems. In this study the amount of ice growth enhancement is predicted theoretically, by performing simplified 1-D calculations, and is then validated in the laboratory through carefully controlled experiments. This study shows that ice volume increase between 50 and 90% is possible by using ...

2006-09-15

237

Thermodynamic and thermoeconomic analyses of a trigeneration (TRIGEN) system with a gas-diesel engine: Part II - An application  

Energy Technology Data Exchange (ETDEWEB)

The paper is Part 2 of the study on the thermodynamic and thermoeconomic analyses of trigeneration system with a gas-diesel engine. In Part 1, thermodynamic and thermoeconomic methodologies for such a comprehensive analysis were provided, while this paper applies the developed methodology to an actual TRIGEN system with a rated output of 6.5 MW gas-diesel engine installed in the Eskisehir Industry Estate Zone, Turkey. Energy and exergy efficiencies, equivalent electrical efficiency, the Public Utility Regulatory Policies Act (PURPA) efficiency, fuel energy saving ratio, fuel exergy saving ratio and other thermodynamic performance parameters are determined for the TRIGEN system. The efficiencies of energy, exergy, PURPA and equivalent electrical efficiency of the entire system are found to be 58.97%, 36.13%, 45.7% and 48.53%, respectively. For the whole system and its components, ...

2010-11-15

238

Thermodynamic and thermoeconomic analyses of a trigeneration (TRIGEN) system with a gas-diesel engine: Part II - An application  

International Nuclear Information System (INIS)

The paper is Part 2 of the study on the thermodynamic and thermoeconomic analyses of trigeneration system with a gas-diesel engine. In Part 1, thermodynamic and thermoeconomic methodologies for such a comprehensive analysis were provided, while this paper applies the developed methodology to an actual TRIGEN system with a rated output of 6.5 MW gas-diesel engine installed in the Eskisehir Industry Estate Zone, Turkey. Energy and exergy efficiencies, equivalent electrical efficiency, the Public Utility Regulatory Policies Act (PURPA) efficiency, fuel energy saving ratio, fuel exergy saving ratio and other thermodynamic performance parameters are determined for the TRIGEN system. The efficiencies of energy, exergy, PURPA and equivalent electrical efficiency of the entire system are found to be 58.97%, 36.13%, 45.7% and 48.53%, respectively. For the whole system and its components, ...

2010-11-01

239

Guide to Combined Heat and Power Systems for Boiler Owners and Operators  

Energy Technology Data Exchange (ETDEWEB)

Combined heat and power (CHP) or cogeneration is the sequential production of two forms of useful energy from a single fuel source. In most CHP applications, chemical energy in fuel is converted to both mechanical and thermal energy. The mechanical energy is generally used to generate electricity, while the thermal energy or heat is used to produce steam, hot water, or hot air. Depending on the application, CHP is referred to by various names including Building Cooling, Heating, and Power (BCHP); Cooling, Heating, and Power for Buildings (CHPB); Combined Cooling, Heating, and Power (CCHP); Integrated Energy Systems (IES), or Distributed Energy Resources (DER). The principal technical advantage of a CHP system is its ability to extract more useful energy from fuel compared to traditional energy systems such as ...

2004-08-19

240

Technological advances and applications of geothermal energy pile foundations and their feasibility in Australia  

Energy Technology Data Exchange (ETDEWEB)

Geothermal energy pile foundations are an alternative energy source for heating and cooling needs. Utilising this source of energy has great potential due to the environmental, economic and social benefits. This paper looks at an extensive amount of literature on the technology behind the system including the overall process, primary considerations for each of the main components including latest developments as well as design implications such as the integration of ground energy systems into structural piles of buildings. Environmental considerations including performance-dependent parameters of the subsurface are described. Main parameters include thermal conductivity, thermal diffusivity, specific heat capacity and moisture content. Temperature and groundwater effects are also discussed and design considerations are provided. Mathematical models are available to aid in the design of these ...

2010-12-15

241

Larger geothermal heat pump plants in the central region of Germany  

Energy Technology Data Exchange (ETDEWEB)

In recent years, several larger geothermal heat pump plants for offices or commercial areas have been designed and built in the central region of Germany, mainly in the Rhein-Main area. Systems with borehole heat exchangers (BHE; in the USA the term Vertical Loop is commonly used) as well as with shallow geothermal doublets (groundwater wells) are operational. New solutions had to be found to adapt the technology to certain site constraints, and innovative components such as thermally-enhanced grouting material have been used. This paper reviews the early development of Ground Source Heat Pumps (GSHP) for commercial buildings, gives details on a number of recent plants and discusses problems that arose during their realisation: UEG Wetzlar, a building with chemical laboratories and one of the first examples of direct cooling from BHE; DFS Langen (German Air Traffic Control Headquarters), with 154 BHE ...

2003-12-01

242

Tests with cleaned and uncleaned gas on a pilot plant. Final report  

Energy Technology Data Exchange (ETDEWEB)

The possibilities for heat recovery in a cast iron melting furnace were studied. A cupola furnace which produces 40 tonnes steel per hour, produces 25,000 Nm/sup 3//h of flue gases which contain 16-22% CO. Taking into account the heat losses at the chimney where fumes are cooled to 200/sup 0/C the recoverable heat is about 12.4-10/sup 6/ kcal/h which mainly consists of combustion heat in CO. This study showed that the heat can be used for the production of electricity, which will be used in the plant. Recovery of 87 kWh of electricity per tonne of steel produced is possible. A steam turbine driven generator of 3.5 MW will be required. The combustion of the low calorific gas (approximately 400 kcal/Nm/sup 3/) has been studied and gave positive results: wet CO gas can be burnt without addition of methane and preheating of air is not required. The pilot plant consisting of a thermic ...

1986-01-01

243

Analysis of the thermal performance of dynamic solar systems  

Energy Technology Data Exchange (ETDEWEB)

This article proposes a model for estimating the effect of the overall thermal resistance of the absorber and the coolant on a solar thermal energy system utilizing advanced heat transfer mediums. Two equations can be used to model a dynamic system: one for the maximum conversion efficiency and one to specify the constraint that, in quasi-steady state, the net energy collected must be transferred to the coolant. These two equations define a constrained optimization problem in two variables, the fluid and the absorber temperatures. The results present interesting implications for liquid metal, direct absorption, and solar evaporating systems.

1996-03-01

244

Heat transfer augmentation for high heat flux removal in rib-roughened narrow channels  

International Nuclear Information System (INIS)

Heat transfer augmentation in narrow rectangular channels in a target system is a very important method to remove high heat flux up to 12 MW/m"2 generated at target plates of a high-intensity proton accelerator of 1.5 GeV and 1 mA with a proton beam power of 1.5 MW. In this report, heat transfer coefficients and friction factors in narrow rectangular channels with one-sided rib-roughened surface were evaluated for fully developed flows in the range of the Reynolds number from 6,000 to 1,00,000; the rib pitch-to-height ratios (p/k) were 10,20 and 30; the rib height-to-equivalent diameter ratios (k/De) were 0.025, 0.03 and 0.1 by means of previous existing experimental correlations. The rib-roughened surface augmented heat transfer coefficients approximately 4 times higher than the smooth surface at Re=10,000, p/k=10 and k/De=0.1; friction factors increase around 22 times higher. In ...

2001-04-08

245

Heat transfer augmentation for high heat flux removal in rib-roughened narrow channels  

Energy Technology Data Exchange (ETDEWEB)

Heat transfer augmentation in narrow rectangular channels in a target system is a very important method to remove high heat flux up to 12 MW/m{sup 2} generated at target plates of a high-intensity proton accelerator of 1.5 GeV and 1 mA with a proton beam power of 1.5 MW. In this report, heat transfer coefficients and friction factors in narrow rectangular channels with one-sided rib-roughened surface were evaluated for fully developed flows in the range of the Reynolds number from 6,000 to 1,00,000; the rib pitch-to-height ratios (p/k) were 10,20 and 30; the rib height-to-equivalent diameter ratios (k/De) were 0.025, 0.03 and 0.1 by means of previous existing experimental correlations. The rib-roughened surface augmented heat transfer coefficients approximately 4 times higher than the smooth surface at Re=10,000, p/k=10 and k/De=0.1; friction factors increase around 22 times higher. ...

1997-03-01

246

Heat management - a technique for resolving the conflicting aims between fuel consumption and comfort; Waermemanagement - ein Werkzeug zur Loesung der Zielkonflikte zwischen Verbrauch und Komfort  

Energy Technology Data Exchange (ETDEWEB)

In view of current trends in motor car development, the author investigates the increasing conflict between higher comfort and lower fuel consumption. The conflict results mainly from insufficient cooling water heating with consumption-optimized engines. So far, it was never necessary to analyze heat flow after cold starting and heat-up of the powertrain, to develop strategies for heat storage and distribution, to remove heat sinks and to use components multifunctionally. The contribution shows that a general heat management strategy for the whole vehicle will result in high potential fuel savings and improved thermal comfort. Using the example of a latent heat store, heating strategies for the engine and transmission system on the one hand and the passenger compartment on the other hand are ...

1999-07-01

247

Experimental investigation of mixed convection heat transfer caused by forced-jets in large enclosure  

Energy Technology Data Exchange (ETDEWEB)

This research investigates experimentally mixed convection and heat transfer augmentation by forced jets in a large enclosure, at conditions simulating those of actual passive containment cooling systems and scales approaching those of actual containment buildings or compartments. The experiment was designed to measure the key parameters governing the heat transfer augmentation by forced jets and investigate the effects of geometric factors, including the jet diameter, jet injection orientation, interior structures, and enclosure aspect ratio. The tests cover a variety of injection modes leading to flow configurations of interest that contribute to reveal the nature of mixing and stratification phenomena in the containment under accident conditions of interest. The heat transfer of mixed convection can be predicted to be controlled by jet Archimedes number and geometric factors. Using a combining rule ...

2004-07-01

248

Application of the porous media model for the LWR process components  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: A porous media solution PORFLO has been developed for the 3-dimensional two-phase flow by describing the process facility in Cartesian or cylindrical coordinates. The local porosity fraction is applied for distinguishing the fluid filled volumes from the solid structures. The solid structure contribute the two-phase flow through the wall friction, flow area and heat transfer. Optionally the solid structure may contain primary liquid of steam generators, steam in the higher temperature and pressure to be condensed or electrical heating power. By using these optional boundary conditions three different process facilities have been analysed. The thermohydraulic solution based on 5-equation approach, where the conservation equations are solved for the liquid and gas (vapour) mass, mixture momentum (giving the velocity only for the mixture), liquid and gas energy, is described shortly. In addition to that the ...

2005-07-01

249

Development of an inactive heat removal system for high temperature reactors  

International Nuclear Information System (INIS)

Growing public and political interests towards incorporating passive safety features in nuclear installations, let Siempelkamp in late 1987 propose a solution consisting of a prestressed cast-iron pressure vessel and a passive heat removal system, integrated in the reactor cell surrounding the vessel. This solution combines the inherent safety of a prestressed metallic pressure vessel with the advantages of a passive heat removal system and thus constitutes a major step towards the goal of further reducing potential residual risks. The design had to meet the boundary conditions for reactor core and reactor building of the modular 200 MWth pebble bed reactor of Siemens/-KWU. The engineering design showed that many input parameters needed for the finite-element-analysis of the overall structure required a verification by measurements in a well scaled test setup. This was especially required for the ...

1994-08-01

250

Study on tritium activity build-up in moderator and primary heat transport systems in 540 MWe reactor  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by Deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on Tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-3 and 4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)

2006-11-13

251

Study on tritium activity build-up in moderator and primary heat transport (PHT) systems in 540 MWe reactor  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)

2005-11-23

252

Solar energy conversion system  

Energy Technology Data Exchange (ETDEWEB)

A solar energy collection and conversion system is disclosed in which a cassegrain mirror system is rotated about a diurnal axis, which axis is adjusted for seasonal variations in the incidence of the sun's rays on the earth's surface. A black body absorption cavity filled with translucent or transparent fluid material is used for direct absorption of the sun's rays. The incident solar energy is absorbed directly by the fluid medium. The fluid within the cavity may be maintained under extremely high pressures and temperatures in order to utilize this fluid as a heat storage medium. Such heat storage is facilitated by apparatus which permits a change in the volume of the reflective cavity in response to the temperature or pressure of the fluid within the cavity.

1981-09-01

253

Protein expression following heat shock in the nervous system of Locusta migratoria  

British Library Electronic Table of Contents (United Kingdom)

There is a thermal range for the operation of neural circuits beyond which nervous system function is compromised. Locusta migratoria is native to the semiarid regions of the world and provides an excellent model for studying neural phenomena. In this organism previous exposure to sublethal high temperatures (heat shock, HS) can protect neuronal function against future hyperthermia but, unlike many organisms, the profound physiological adaptations are not accompanied by a robust increase of Hsp70 transcript or protein in the nervous system. We compared Hsp70 increase following HS in the tissues of isolated and gregarious locusts to investigate the effect of population density. We also localized Hsp70 in the metathoracic ganglion (MTG) of gregarious locusts to determine if HS affects Hsp70 ...

2011-01-01

254

Nomographs for the optimum solar pond driven LiBr/ZnBr sub 2 /CH sub 3 OH absorption-refrigeration system  

Energy Technology Data Exchange (ETDEWEB)

The paper presents a procedure for the calculation of an absorption-refrigeration plant that uses an LiBr/ZnBr{sub 2}/CH{sub 3}OH solution and is driven throughout the year by heat received from a solar pond. The calculations for the solar pond are based on a finite-difference solution of the transient heat conduction differential equation during the year, and the operation of the refrigeration unit is simulated by the use of functions describing the thermodynamic behaviour of the working medium. On the basis of the procedure devised, correlations and nomographs are developed that describe the seasonally optimum operation of the proposed composite system. The nomographs may be employed for a first estimation in the design of such systems. (Author).

1992-07-01

255

Modeling and control of a novel heat exchange reactor, the Open Plate Reactor  

British Library Electronic Table of Contents (United Kingdom)

A new chemical reactor, the Open Plate Reactor, is being developed by Alfa Laval AB. It combines good mixing with high heat transfer capacity into one operation. With the new concept, highly exothermic reactions can be produced using more concentrated reactants. A nonlinear model of the reactor is derived and a control system is developed. For temperature control a cooling system is designed and experimentally verified, which uses a mid-ranging control structure to increase the operating range of the hydraulic equipment. A Model Predictive Controller is proposed to maximize the conversion under hard input and state constraints. An extended Kalman filter is designed to estimate unmeasured concentrations and parameters. Simulations show that the designed control system gives high conversion ...

2007-01-01

256

Bioreactors  

Energy Technology Data Exchange (ETDEWEB)

Composting is once again gaining interest among ecological engineers in view of greener industrial and residential activities. Uniform composting is needed to ensure decomposition and to keep the whole system at the same composting stage. A homogeneous temperature must be maintained throughout the media. A bioreactor design consisting of a heater core made of copper tubing was designed and tested. Two four-inch holes were made at the top and bottom of the barrel to allow air to flow through the system and promote aerobic composting. Once composting began and temperature increased, the water began to flow through the copper piping and the core heat was distributed throughout the medium. Three thermocouples were inserted at different heights on a 200 litre plastic barrel fitted with the aforementioned apparatus. Temperature variations were found to be considerably lower when the apparatus was operated with the ...

2010-07-01

257

Air pollution abatement at the crossroads. Emissionsminderungstechnik am Scheideweg  

Energy Technology Data Exchange (ETDEWEB)

A brief survey of present air pollution abatement requirements relevant to domestic heating systems is followed by a comparative evaluation of the latest results worked out on the part of boiler and burner manufacturers, and the legal requirements and existing regulations. Details are given on the limiting values required by law, the regulations valid for domestic heating systems, and the values fixed according to scientific knowledge and research results (development of NO{sub x} and CO, flame temperature dependence, table comparing CO and NO{sub x} limiting values for different types of burners and boilers). Access is given to primary air pollution abatement measures (cooling of flames, absorber rods, influence of mixing pressure), modern burner and boiler systems, and secondary measures suited for smaller boilers. (HWJ).

1989-05-01

258

Operational test report integrated system test (ventilation upgrade)  

Energy Technology Data Exchange (ETDEWEB)

Operational Final Test Report for Integrated Systems, Project W-030 (Phase 2 test, RECIRC and HIGH-HEAT Modes). Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks, including upgraded vapor space cooling and filtered venting of tanks AY101, Ay102, AZ101, AZ102.

1999-10-05

259

Energy flux operator, current conservation and the formal Fourier's law  

International Nuclear Information System (INIS)

By revisiting previous definitions, we show that one can define an energy current operator that satisfies the continuity equation for a general Hamiltonian in one dimension. This expression is useful for studying electronic, phononic and photonic energy flow in linear systems and in hybrid structures. The definition allows us to deduce the necessary conditions that result in current conservation for general-statistics systems. The discrete form of the Fourier's law of heat conduction naturally emerges in the present definition.

2009-01-16

260

Economic analysis of cogeneration. January 1976-December 1980 (citations from the Energy Data Base). Report for January 1976-December 1980  

Energy Technology Data Exchange (ETDEWEB)

This retrospective bibliography contains citations concerning economic analysis of the techniques and technology for cogeneration and the effects of government policies and industrial attitudes toward cogeneration. Combined energy systems and combined manufacturing/energy systems which utilize waste heat and waste products as well as traditional fuels are included. (Contains 71 citations, fully indexed and including a table of contents.)

1980-12-01

261

Dissipativity for linear neutral distributed parameter systems: LOI approach  

British Library Electronic Table of Contents (United Kingdom)

In this work dissipativity of linear neutral distributed parameter systems has been addressed. Delay-dependent sufficient conditions for the dissipativity with respect to the infinite-dimensional version of energy supply rate (Q"1,S"1,R"1) characterized exclusively by unbounded operator Q"1 are established in terms of linear operator inequalities (LOIs). Finally, the 3-dimensional heat equation illustrates our result.

2012-01-01

262

Acute Toxicity Evaluation of JP-8 Jet Fuel and JP-8 Jet Fuel Containing Additives.  

Science.gov (United States)

To reduce fuel fouling in current U.S Navy and Air Force aircraft systems and to provide additional heat sink and thermal stability for future systems, the Air Force is developing an improved JP-8 jet fuel (JP-8 + 100). Two companies (Betz and Mobil) have...

1996-01-01

263

Wax and hydrate control with electrical power  

Energy Technology Data Exchange (ETDEWEB)

Electrical heating of subsea flowlines is an effective way to prevent wax and hydrate information, especially for long transportation distances and in low-temperature deep water. Systems are available for use in conjunction with bundles, pipe-in-pipe, and wet-thermal-insulation systems. These systems provide environmentally friendly fluid-temperature control without chemicals or flaring for pipeline depressurizing. Enhanced production is achieved because no time is lost by unnecessary depressurizing, pigging, heating-medium circulation, or removal of hydrate and wax blockages. The seabed temperature at 100-m and greater water depths may range from 7 to {minus}1.5 C, causing a rapid cooling of the hot well streams being transported in subsea flowlines. Under these supercooling conditions, vulnerable crude oils and multiphase compositions will deposit wax and asphalts; also the ...

1997-08-01

264

Assessment of RELAP5/MOD3/CANDU"+ to Wolsung-1 D_2O leakage event  

International Nuclear Information System (INIS)

In order to evaluate the integrated performance of RELAP5/MOD3/CANDU"+ for CANDU operational transient analysis, we assesed the code to the D_2O leakage event occurred at Wolsung-I, 600 MW(e) CANDU reactor, on Oct. 20, '94. D_2O leakage event was initiated by stuck opening of liquid relief valve No.4 in primary coolant pressure and level control system. Assessment calculation was performed for the plant transients up to 1000 seconds after the initiating event. Calculation results are compared with those measured in primary heat transport system, pressure and inventory control system and boiler secondary system. Comparison with the plant trip log shows that the RELAP5/CANDU"+ is able to simulate the plant transients properly, from which we can conclude that the RELAP5/CANDU"+ is validated for application to CANDU operational transient analysis. CANDU specific models used in the ...

2001-10-01

265

The cooperative housing society Vaarst Vestervang - green building; Andelsboligforeningen Vaarst Vestervang - groent byggeri  

Energy Technology Data Exchange (ETDEWEB)

Vaarst Vestervang (Denmark) comprises 16 villas and 1 communal building. The complex was designed by the inhabitants themselves with the aim of polluting the environment as little as possible. The land area constitutes 69.000 square meters where it is possible to grass animals. The document reports a measuring programme concerning the overall heat consumption as one of the main aims of the inhabitants is to save energy and thus contribute to the protection of the environment. The capacity of the solar collectors predominantly used in the building complex was 235 kWh/m{sup 2}. Supplementary heating is provided by boilers fired with wood. The measuring system is described in detail. Tables show the influence of heat transmission losses, ventilation, airing out of rooms, the angle of the sun`s rays within the buildings and heating needs on energy consumption. Energy consumption data is ...

1993-10-01

266

Optimisation of solar-heated cavity receivers with paraboloid collectors. Optimierung von solar beheizten Hohlraumstrahlungsempfaengern mit Paraboloidkollektoren  

Energy Technology Data Exchange (ETDEWEB)

The authors investigate the optimisation of solar-heated cavity receivers in which solar energy collected by a paraboloid collector is converted into electrical energy. The focussed solar energy enters the receiver through an aperture to heat the working fluid, which flows inside the receiver tubes and is compressed by the compressor of a gas turbine system, to the highest process temperature. A method of calculating the distribution on the inner receiver surfaces of the solar radiation reflected by the paraboloid collector is presented to begin with. The interchange of radiant energy inside the receiver cavity can be calculated on this basis, including the radiation loads, the temperatures of the inner receiver walls, and the radiative and convective losses. The temperature fields in the tube walls must be known for determining the strength required of receiver tubes; they can be derived from the useful ...

1984-01-01

267

Experimental study of the characteristics of solidification of stearic acid in an annulus and its thermal conductivity enhancement  

Energy Technology Data Exchange (ETDEWEB)

The thermal and heat transfer characteristics of stearic acid during the solidification processes were investigated experimentally in a vertical annulus energy storage system. The temperature distribution and temperature variations with time at different radial positions during the freezing processes were obtained. The thermal characteristics of the stearic acid, including movement of the solid-liquid interface in the radial direction, and the effects of Reynolds number on the heat transfer parameters were studied. The heat flux was estimated by using a simple approximate model. A new copper fin was designed and fixed to the electrical heating rod to enhance the thermal conductivity of the stearic acid. The results show that the new fin can enhance both the conduction and the natural convection heat transfer of the PCM, and the enhancement factor during ...

2005-04-01

268

Experimental study of the characteristics of solidification of stearic acid in an annulus and its thermal conductivity enhancement  

Energy Technology Data Exchange (ETDEWEB)

The thermal and heat transfer characteristics of stearic acid during the solidification processes were investigated experimentally in a vertical annulus energy storage system. The temperature distribution and temperature variations with time at different radial positions during the freezing processes were obtained. The thermal characteristics of the stearic acid, including movement of the solid-liquid interface in the radial direction, and the effects of Reynolds number on the heat transfer parameters were studied. The heat flux was estimated by using a simple approximate model. A new copper fin was designed and fixed to the electrical heating rod to enhance the thermal conductivity of the stearic acid. The results show that the new fin can enhance both the conduction and the natural convection heat transfer of the PCM, and the enhancement factor during ...

2005-04-01

269

Model and simulation of heat transfer, magnetite oxidation and NOx formation in a grate-kiln taconite pellet induration furnace  

Energy Technology Data Exchange (ETDEWEB)

A numerical model was developed to simulate the combined effects of heat transfer, magnetite oxidation, and NO{sub x} formation in a grate-kiln furnace for taconite pellet induration. Heat transfer from the flame in the kiln was described by the net radiation method. The shrinking core model was used to account for magnetite oxidation on the grate. A novel approach to oxidation of tumbling pellets in a kiln was derived. The Zeldovich mechanism was used to predict thermal NO generation. Temperature fluctuations in the gas streams were estimated with a clipped Gaussian probability density function. The thermal energy balances and mass balances resulted in coupled systems of first-order differential equations, which were solved numerically. The model is capable of predicting NO production and magnetite oxidation in agreement with observation of plant performance. Although the design of the grate-kiln ...

1996-12-31

270

Heavy water reactor facility large-scale containment cooling test program  

Science.gov (United States)

The Heavy Water Reactor Facility (HWRF), as part of the defense-in-depth philosophy to mitigate the effect of design-basis and severe accidents, is equipped with a passive containment cooling system (PCCS). The function of the PCCS is to provide a safety-grade path to the ultimate heat sink for the removal of the reactor coolant system sensible heat and core decay heat. Ambient air enters an annular space between the steel containment shell and the surrounding concrete shield building through inlets in the shield building wall, is heated via natural convection, rises, and exits the building through a chimney located above the containment dome. A test program is in place to access parameters important to the effective operation of the PCCS. This paper focuses on the large-scale tests (LSTs). The objectives of these tests are as follows: (1) demonstrate natural ...

1992-01-01

271

Heavy water reactor facility large-scale containment cooling test program  

International Nuclear Information System (INIS)

The Heavy Water Reactor Facility (HWRF), as part of the defense-in-depth philosophy to mitigate the effect of design-basis and severe accidents, is equipped with a passive containment cooling system (PCCS). The function of the PCCS is to provide a safety-grade path to the ultimate heat sink for the removal of the reactor coolant system sensible heat and core decay heat. Ambient air enters an annular space between the steel containment shell and the surrounding concrete shield building through inlets in the shield building wall, is heated via natural convection, rises, and exits the building through a chimney located above the containment dome. A test program is in place to access parameters important to the effective operation of the PCCS. This paper focuses on the large-scale tests (LSTs). The objectives of these tests are as follows: (1) demonstrate natural ...

1992-11-15

272

Experimental evaluation of a non-azeotropic working fluid for geothermal heat pump system  

Energy Technology Data Exchange (ETDEWEB)

Geothermal energy resources are found in many countries. A reasonable and efficient utilization of these resources has been a worldwide concern. The application of geothermal heat pump systems (GHPS) can help increase the efficiency of using geothermal energy and reduce the thermal pollution to the earth surface. However, this is only possible with a proper working fluid. In this paper, a non-azeotropic working fluid (R290/R600a/R123) is presented for a GHPS where geothermal water at 40-45{sup o}C and heating network water at 70-80{sup o}C serve as the low and high temperature heat sources. Experimental results show that the coefficient of performance (COP) of a GHPS using the working fluid is above 3.5 with the condensation temperature above 80{sup o}C and the condensation pressure below 18 bar, while the temperature of the geothermal water is reduced from 40-46{sup o}C to 31-36{sup o}C. (author)

2004-06-01

273

Experimental evaluation of a non-azeotropic working fluid for geothermal heat pump system  

International Nuclear Information System (INIS)

Geothermal energy resources are found in many countries. A reasonable and efficient utilization of these resources has been a worldwide concern. The application of geothermal heat pump systems (GHPS) can help increase the efficiency of using geothermal energy and reduce the thermal pollution to the earth surface. However, this is only possible with a proper working fluid. In this paper, a non-azeotropic working fluid (R290/R600a/R123) is presented for a GHPS where geothermal water at 40-45 deg. C and heating network water at 70-80 deg. C serve as the low and high temperature heat sources. Experimental results show that the coefficient of performance (COP) of a GHPS using the working fluid is above 3.5 with the condensation temperature above 80 deg. C and the condensation pressure below 18 bar, while the temperature of the geothermal water is reduced from 40-46 deg. C to 31-36 deg. C.

2004-06-01

274

Microwave drying of fine coal  

Energy Technology Data Exchange (ETDEWEB)

Drying fine coal by microwaves is now being considered as a viable option by some coal producers. The interest in microwaves is due to problems encountered with current thermal or hot-air drying methods. The technical feasibility of drying minus 5mm coal fines by microwaves was demonstrated using pilot-scale continuous processing system. Results showed that water absorbs microwave energy significantly; but coal does not. Secondly, microwave energy heats only the water, unlike existing drying methods, which heat both water and coal. Finally, the method was found to be energy efficient and minimised the generation of dust.

1989-03-01

275

Low temperature solar-to-electric power conversion system  

Science.gov (United States)

An electric power generating apparatus is described, including: a solar collector; a primary thermal loop including primary thermal fluid; a cavity receiver to receive reflected solar energy from the solar reflector, convert the solar energy into thermal energy, and transmit the thermal energy to the primary thermal fluid by heating the primary thermal fluid not to exceed a given temperature, the given temperature being substantially equal to 700 F; a Stirling engine receiving the primary thermal fluid heated by the cavity receiver, including means to generate mechanical power and means to generate electrical power from the means to generate mechanical power.

1993-07-20

276

Geothermal resource assessment of the New England states  

Energy Technology Data Exchange (ETDEWEB)

With the exception of Sand Springs in Williamstown, Massachusetts, there are no identifiable hydrothermal geothermal resources in the New England region. The radioactive plutons of the White Mountains of New Hampshire do not, apparently, contain sufficient stored heat to make them a feasible target for an induced hydrothermal system such as exists at Fenton Hill near Los Alamos, New Mexico. The only potential source of low grade heat is the large volume of ground water contained within the unconsolidated sediments related to the Pleistocene glaciation of the region. During the course of the survey an unusual and unexplained thermal anomaly was discovered in St. Johnsbury, Vermont, which is described.

1982-01-01

277

Development of low cost contacts to silicon solar cells  

Science.gov (United States)

The results of the second phase of the program of developing low cost contacts to silicon solar cells using copper are presented. Phase 1 yielded the development of a plated Pd-Cr-Cu contact system. This process produced cells with shunting problems when they were heated to 400 C for 5 minutes. Means of stopping the identified copper diffusion which caused the shunting were investigated. A contact heat treatment study was conducted with Pd-Ag, Ci-Ag, Pd-Cu, Cu-Cr, and Ci-Ni-Cu. Nickel is shown to be an effective diffusion barrier to copper.

1980-01-01

278

A phenomenological Landau theory for electromagnons in cubic spinel multiferroic CoCr_2O_4  

International Nuclear Information System (INIS)

Non-anisotropic free energy is considered which under minimization yields two magnetic phases: a conical spin density wave and a low temperature conical cycloid. Using equations of motion, the excitation spectrum is studied. Knowing the nature of these excitations, the dielectric function as well as the fluctuation specific heat is computed and compared with the experimental spectrum. Due to the electromagnon going soft, the dielectric function (imaginary part) as well as the specific heat capacity show peaks at the temperature where ferroelectricity appears in the system.

2010-06-09

279

The effects of radiation on unsteady mhd convective heat transfer past a semi-infinite vertical porous moving surface with variable suction  

Scientific Electronic Library Online (English)

Abstract in english Numerical solutions for the effects of radiation on a MHD convective heat transfer past a semi-infinite porous plate with a magnetic field are obtained. It is assumed that the porous plate moves with a constant velocity in the direction of fluid flow, and the free stream velocity follows the exponentially increasing small perturbation law. The magnetic field acts perpendicular to the porous surface which absorbs the fluid with a suction velocity varying with time. The gov (more) erning equations for the flow are transformed into a system of nonlinear ordinary differential equations by perturbation technique and then are solved numerically by using the shooting method. The effects of the various parameters on the velocity, temperature profiles as well as the surface skin-friction and surface heat transfer are illustrated graphically.

2008-12-01

280

Realization of good indoor climate in low-energy office  

Energy Technology Data Exchange (ETDEWEB)

Good indoor air quality and thermal comfort, as well as low energy consumption, were achieved in an environment friendly experimental METOP-office building in Espoo, Finland. The consumption of heating and cooling energy was minimized by installation of energy-efficient windows, good CFC-free thermal insulation of the building envelope, the individually-controlled ventilation and room temperatures, heat recovery and energy-storing structures. According to the study carried out in 1990-1993, the heating energy was 13 kWh/m{sup 3}, 60% lower than the average consumption. The index of the satisfaction of thermal comfort was over 90%. Concentrations of all the measured indoor air pollutants were low. Ventilation rates could be chosen in each office room from 10 to 40 dm{sup 3}/s. The noise level of the ventilation system was low and the lighting level was pleasant. (author)

1994-12-31

281

Irreversible Performance of a Quantum Harmonic Heat Engine  

CERN Document Server

The unavoidable irreversible losses of power in a heat engine are found to be of quantum origin. Following thermodynamic tradition a model quantum heat engine operating by the Otto cycle is analyzed. The working medium of the model is composed of an ensemble of harmonic oscillators. A link is established between the quantum observables and thermodynamical variables based on the concept of canonical invariance. These quantum variables are sufficient to determine the state of the system and with it all thermodynamical variables. Conditions for optimal work, power and entropy production show that maximum power is a compromise between the quasistatic limit of adiabatic following on the compression and expansion branches and a sudden limit of very short time allocation to these branches. At high temperatures and quasistatic operating conditions the efficiency at maximum power coincides with the endoreversible result. The optimal ...

2006-01-01

282

Investigation of mixed convection in a large rectangular enclosure  

Energy Technology Data Exchange (ETDEWEB)

This experimental research investigates mixed convection and heat transfer augmentation by gaseous forced jets in a large enclosure, at conditions simulating those of passive containment cooling systems for Gen III+ passively safe reactors. The experiment is designed to measure the key parameters governing heat transfer augmentation by forced jets, and to investigate the effects of geometric factors, including the jet diameter, jet injection orientation, interior structures, and enclosure aspect ratio. The tests cover a variety of injection modes leading to flow configurations of interest for mixing and stratification phenomena in containments under accident conditions. Correlations for heat transfer augmentation by forced jets are developed and compared with experimental data. The characteristic recirculation speed inside the enclosure is introduced and analyzed. Steady stratified temperature ...

2007-05-15

283

Investigation of mixed convection in a large rectangular enclosure  

International Nuclear Information System (INIS)

This experimental research investigates mixed convection and heat transfer augmentation by gaseous forced jets in a large enclosure, at conditions simulating those of passive containment cooling systems for Gen III+ passively safe reactors. The experiment is designed to measure the key parameters governing heat transfer augmentation by forced jets, and to investigate the effects of geometric factors, including the jet diameter, jet injection orientation, interior structures, and enclosure aspect ratio. The tests cover a variety of injection modes leading to flow configurations of interest for mixing and stratification phenomena in containments under accident conditions. Correlations for heat transfer augmentation by forced jets are developed and compared with experimental data. The characteristic recirculation speed inside the enclosure is introduced and analyzed. Steady stratified temperature ...

2007-05-01

284

Furnace for rapid change of temperature for neutron diffraction  

International Nuclear Information System (INIS)

A new furnace for neutron diffraction experiments is capable of heating and cooling a sample very rapidly. The rapid heating is done by two circular infrared lamps placed over and under a sample, whose radiation is roughly focused on the sample by a reflector. The rapid cooling is done by high-pressure gas blows against the sample from two circular nozzles which are also placed over and under the sample. This system enables us to obtain the heating rate of over 1000"0C/min and cooling rate of -500"0C/min for an alloy of 10 mm diameter and 30 mm length. The performance is sufficient to carry out some kinetics measurements in real-time neutron diffraction by the use of a position-sensitive detector. This kind of experiment is demonstrated by the observation of the relaxation process of order--disorder transitions in CuZn and Ni_3Mn alloys.

285

Clean combustion of solid fuels  

International Nuclear Information System (INIS)

A chemical-looping process is proposed for the clean combustion of solid fuels for electric power or heat generation. The process is based on coal gasification with CO_2 to produce CO. The CO then reduces CaSO_4, which is used as an oxygen carrier, in a separate reactor to give CaS and CO_2. A portion of the CO_2 is recycled for the gasification stage and the rest can be sent for sequestration. The CaS is sent to another reactor for oxidation with air and to generate heat or power. The overall thermal effect is the same as direct combustion, but separation of CO_2 and other pollutants, such as sulphur, is achieved. In comparison with conventional chemical-looping combustion of natural gas, much less water is present in the CO_2 product, and hence the loss of heat energy and corrosion of the fuel-reactor system can be reduced.

2008-01-01

286

Building design using the energy nomographs  

Energy Technology Data Exchange (ETDEWEB)

Today's building industry is promoting the use of renewable sources of energy to heat, cool, and illuminate commercial buildings. Societies such as the International Solar Energy Society sponsor conferences such as this one to share knowledge and experience in the area of solar energy. However, the technologies presented here assume a need for heating, cooling or illumination. A simple technique is presented for determining the actual heating, cooling, and lighting requirements for commercial buildings, and for reducing those requirements through proper building design before applying solar technologies. The energy nomographs are a graphic energy design tool developed to aid designers in making cost effective decisions about energy alternatives early in the design process. Reducing loads at this point can help reduce the expense of a passive or active solar system which is usually sized to meet ...

1983-06-01

287

An inexact Newton method for fully-coupled solution of the Navier-Stokes equations with heat and mass transport  

Energy Technology Data Exchange (ETDEWEB)

The solution of the governing steady transport equations for momentum, heat and mass transfer in flowing fluids can be very difficult. These difficulties arise from the nonlinear, coupled, nonsymmetric nature of the system of algebraic equations that results from spatial discretization of the PDEs. In this manuscript the authors focus on evaluating a proposed nonlinear solution method based on an inexact Newton method with backtracking. In this context they use a particular spatial discretization based on a pressure stabilized Petrov-Galerkin finite element formulation of the low Mach number Navier-Stokes equations with heat and mass transport. The discussion considers computational efficiency, robustness and some implementation issues related to the proposed nonlinear solution scheme. Computational results are presented for several challenging CFD benchmark problems as well as two large scale 3D flow simulations.

1997-02-01

288

A numerical solution of unsteady MHD convection heat and mass transfer past a semi-infinite vertical porous moving plate using element free Galerkin method  

British Library Electronic Table of Contents (United Kingdom)

In this paper, the unsteady MHD free convection heat and mass transfer of viscous fluid flowing through a Darcian porous regime adjacent to a moving vertical semi-infinite plate under Soret and Dufour effect have been examined. Viscous dissipation effects are included in the energy equation. A uniform magnetic field is applied transversely to the direction of the flow. The differential equations governing the problem have been transformed by a similarity transformation into a system of non-dimensional differential equations which are solved numerically by element free Galerkin method. The influence of Grashof number (Gr), magnetic parameter (M), heat absorption parameter (Q), permeability parameter (K), Schmidt number (Sc), Soret number (Sr), and Dufour number (Du) on the velocity, tempera...

2010-01-01

289

Soft cooling with concrete: A simple system ensures a comfortable room climate; Sanfte Kuehlung aus Beton: Behagliches Raumklima mit einfachem System  

Energy Technology Data Exchange (ETDEWEB)

After cooling ceilings and source ventilation, simple air conditioning systems like thermal activation of concrete cores are gaining general acceptance. Parallel to this, ground source cooling systems are reducing the need for cold generation. Air conditioning systems of this type are favoured by producers of floor heating systems looking for a new market segment. [German] Nach Kuehldecken und Quellueftung gewinnen jetzt einfach aufgebaute Raumklimaanlagen, wie die thermische Betonkernaktivierung, immer mehr Anhaenger. Parallel dazu werden Verfahren zur Erdkaeltenutzung entwickelt, die den Anteil kuenstlich erzeugter Kaelte weiter zurueckdraengen. Forciert wird diese Art der Klimatisierung insbesondere durch die Hersteller von Fussbodenheizungen, fuer die sich hier ein neues Marktsegment eroeffnet. (orig.)

1999-10-01

290

Refrigerator operating experience on whole body MRI magnet systems  

International Nuclear Information System (INIS)

Several refrigerators for liquid helium and liquid nitrogen systems have been integrated successfully into IGC manufactured whole body Magnetic Resonance Imaging (MRI) magnet systems. The refrigerators have been tested in systems with magnetic fields of 0.6T to 1.5T. Tests were performed to study the effectiveness of the refrigerators, the magnetic field effects on the refrigerators, the effect of the refrigerators on the field uniformity and magnetic resonance image quality. The interface between the refrigerator and the whole body MRI magnet system cryostat was specifically designed to allow retrofit to the existing IGC magnet systems, while ensuring good heat transfer characteristics and good vibration isolation from the cryostat. The interface between the refrigerator and the cryostat and the refrigerator test results are presented.

1985-08-01

291

AZSh protective circuit breaker system  

Energy Technology Data Exchange (ETDEWEB)

The AZSh protective circuit breakers developed by the VNIIVEh Institute and the Prokop'evsk plant for mine automation will replace a number of circuit breaker systems used in underground coal mines in the USSR. The standardized AZSh circuit breaker generation consists of 3 basic types: the AZSh-1, the AZSh-2 and the AZSh-3 systems for power systems with 380 or 660 V voltage. Block scheme of the AZSh system is given. Its specifications are discussed. The AZSh circuit breakers are used for protection of transformer stations from overload and heating as well as for automatic shutdown of energy supply to a power system in emergency situations. Design, basic elements and operation of the AZSh-1, the AZSh-2 and the AZSh-3 protective circuit breakers is evaluated. Commercial production of the AZSh started in 1983.

1984-08-01

292

Thermal properties and thermal reliability of eutectic mixtures of some fatty acids as latent heat storage materials  

Energy Technology Data Exchange (ETDEWEB)

The present study deals with two subjects. The first one is to determine the thermal properties of lauric acid (LA)-stearic acid (SA), myristic acid (MA)-palmitic acid (PA) and palmitic acid (PA)-stearic acid (SA) eutectic mixtures as latent heat storage material. The properties were measured by the differential scanning calorimetry (DSC) analysis technique. The second one is to study the thermal reliability of these materials in view of the change in their melting temperatures and latent heats of fusion with respect to repeated thermal cycles. For this aim, the eutectic mixtures were subjected to 360 repeated melt/freeze cycles, and their thermal properties were measured after 0, 90,1 80 and 360 thermal cycles by the technique of DSC analysis. The DSC thermal analysis results show that the binary systems of LA-SA in the ratio of 75.5:24.5 wt.%, MA-PA in the ratio of 58:42 wt.% and PA-SA in the ratio of 64.2:35.8 wt.% form ...

2004-02-01

293

Selecting the Design Entering Water Temperature for Vertical Geothermal Heat Pumps in Cooling-Dominated Applications  

International Nuclear Information System (INIS)

At a military base in the Southeastern US, an energy services company (ESCO) has proposed to retrofit more than 1,000 family residences with geothermal heat pumps as part of an energy savings performance contract (ESPC). Each residence is to have one heat pump with its own ground heat exchanger consisting of two or more vertical bores. A design firm hired by the ESCO sized the heat pumps to meet peak cooling loads, and sized the borefields to limit the maximum entering water temperature (EWT) to the heat pumps to 95 F (35 C). Because there is some disagreement in the geothermal heat pump industry over the peak temperature to be used for design (some designers and design manuals recommend temperatures as low as 85 F[29 C], while equipment manufacturers and others specify temperatures of 100 F[38 C] or higher) the authors were requested to examine the designs in ...

294

Performance test of a small compact combined heating and electricity generating plant; Erfolgskontrolle Klein-Blockheizkraftwerk  

Energy Technology Data Exchange (ETDEWEB)

The present project examined the operating characteristics and application possibilities of a new, compact combined heating and electricity generating unit with a thermal output of 14,5 kW and a generating capacity of 5,5 kW. Such a module was installed in a plant in Arlesheim (Canton of Basel-Country) and subject to performance measurements. The small heating and generating plant is designed for cyclic operation (without heat storage) and is very compact and low in cost. The heating and generating unit conforms to all Swiss regulations relating to electrical installations and air pollution control. The NO{sub x} emissions of the unit (400 mg/m{sup 3} in steady state operation) are above the limits of LRV 92 (80 mg/m{sup 3}), but the regulation does not apply for units in this power range. The electricity generation costs are approximately CHF 0.16/kWh. It therefore makes sense to install the module in ...

1995-12-01

295

Heat transfer augmentation by gas-particle two-phase flow  

International Nuclear Information System (INIS)

The helium-cooled HTGR (High Temperature Gas-cooled Reactor) will take an important position in the global energy strategy. It is expected to supply not only electricity but also high quality thermal energy for various industries and local utilities without exhausting any green house effect gas or acid rain gas. The key R and D issue of the HTGR is economical competitiveness, particularly against light water reactors. Due to the poor heat transfer of the single phase helium, the HTGR's volumetric power density is restricted to tenth of corresponding PWR's value so that increasing the power density by improving heat transfer is strongly desired. The standstill can be broken through by adopting gas-solid suspension medium. Its heat transfer performance is quite excellent. Its heat capacity can be increased drastically without excessive pressurization. Although the thermal radiation is a dominant ...

1995-06-01

296

Experimental study on heat transfer augmentation for high heat flux removal in rib-roughened narrow channels  

Energy Technology Data Exchange (ETDEWEB)

Frictional pressure drop and heat transfer performance in a very narrow rectangular channel having one-sided constant heat flux and repeated-ribs for turbulent flow have been investigated experimentally, and their experimental correlations were obtained using the least square method. The rib pitch-to-height ratios(p/k) were 10 and 20 while holding the rib height constant at 0.2mm, the Reynolds number(Re) from 2,414 to 98,458 under different channel heights of 1.2mm, 2.97mm, and 3.24mm, the rib height-to-channel equivalent diameter(k/De) of 0.03, 0.04, and 0.09 respectively. The results show that the rib-roughened surface augments heat transfer 2-3 times higher than that of the smooth surface with the expense of 2.8-4 times higher frictional pressure drop under Re=5000-10{sup 5}, p/k=10, and H=1.2mm. Experimental results obtained by channel height, H=1.2mm shows a little bit higher heat transfer and ...

1997-07-01

297

Choice of energy data in environmental assessment of the built environment  

Energy Technology Data Exchange (ETDEWEB)

Life cycle oriented methods are increasingly used for environmental assessments (EAs) of the built environment. However, many assumptions are made in such assessments, potentially influencing the results and making the assessment more ambiguous. To increase the reliability of EAs, consequences of the assumptions made have to be better understood. Since energy use in the operation and maintenance phase is an important factor decisive for the overall environmental performance of a building, the purpose of this study is to investigate how the selection of heat and electricity mix affects the assessed environmental performance of buildings. It also aims to suggest how to choose heat and electricity data in EAs of the built environment in general. Applying four different modes of electricity production and two different modes of heat production in a case study of three different buildings with different technical solutions for ...

2003-03-01

298

High efficiency power production from biomass and waste  

Energy Technology Data Exchange (ETDEWEB)

Two-stage gasification allows power production from biomass and waste with high efficiency. The process involves pyrolysis at about 550C followed by heating of the pyrolysis gas to about 1300C in order to crack hydrocarbons and obtain syngas, a mixture of H2, CO, H2O and CO2. The second stage produces soot as unwanted by-product. Experimental results are reported on the suppression of soot formation in the second stage for two different fuels: beech wood pellets and Rofire pellets, made from rejects of paper recycling. Syngas obtained from these two fuels and from an industrial waste fuel has been cleaned and fed to a commercial SOFC stack for 250 hours in total. The SOFC stack showed comparable performance on real and synthetic syngas and no signs of accelerated degradation in performance over these tests. The experimental results have been used for the design and analysis of a future 25 MWth demonstration plant. As an alternative, a 2.6 MWth ...

2008-11-15

299

Engineering study on steam storage power generation. System screening and efficiency  

Energy Technology Data Exchange (ETDEWEB)

Large scale steam storage power generation, one of the new energy storage systems for the future of inflexible electric power sources consisting of nuclear and coal power plants has been studied on the subjects of the systems to be attached to coal and nuclear power units, of the definition of storage efficiency and of the vertical steam storage vessel technology. Steam storage power generation may be hopeful for its higher efficiency similarly defined as of pumped storage plants while high temperature heat storage and the internal structure of large vertical steam storage vessel (accumulator) need to be developed.

1981-11-01

300

Determination of the radiation distribution in solar heated receivers with real parabolic dish collectors  

Energy Technology Data Exchange (ETDEWEB)

In an ideal system the surface of the dish is perfectly parabolic (no contour flaws are present), and the sun rays fall on the dish surface parallel to the focal axis (no sun tracking flaws are present). These two conditions are not realizable in practice; in this case, the parabolic dish system is called real system. In this paper a procedure for analysing the flux distribution on the receiver internal surfaces is presented for a cavity receiver with a real parabolic dish collector. First, the theoretical principles are discussed. Then the effect of the inaccuracy in the collector and in the sun tracking on the insolation pattern is described using an example.

1987-06-01

301

CIRNAT - a code for one and two-phase natural circulation  

Energy Technology Data Exchange (ETDEWEB)

CIRNAT, a one-dimensional code for natural circulation analysis, was described. The homogeneous approach was adopted for the two-phase flow regime and different heat transfer regimes were considered. The code was exhaustively tested for one-phase flow systems. For two phase flows a boiling/condensing system was simulated. The results are qualitatively correct but the oscillations observed at the system were not captured by the model. Other two-phase flow tests must be done to show the limits of the homogeneous approach before the introduction of a more complex model. (author)

1996-07-01

302

CIRNAT - a code for one and two-phase natural circulation  

International Nuclear Information System (INIS)

CIRNAT, a one-dimensional code for natural circulation analysis, was described. The homogeneous approach was adopted for the two-phase flow regime and different heat transfer regimes were considered. The code was exhaustively tested for one-phase flow systems. For two phase flows a boiling/condensing system was simulated. The results are qualitatively correct but the oscillations observed at the system were not captured by the model. Other two-phase flow tests must be done to show the limits of the homogeneous approach before the introduction of a more complex model. (author)

1996-11-11

303

Studies on magnetohydrodynamic flow characteristics and heat transfer of liquid metal two-phase flow cooling systems for a magnetically confined fusion reactor  

Energy Technology Data Exchange (ETDEWEB)

Liquid metal cooling for the first wall and blanket of a magnetic confinement fusion reactor has various advantages. However, it has the disadvantages of large magnetohydrodynamic pressure drops and heat transfer deterioration under a strong magnetic field. Thus, the present authors have proposed cooling with a helium-lithium annular mist flow as well as the cooling with a liquid metal boiling flow, and as fundamental studies, investigated the effect of a magnetic field on the flow characteristics and heat transfer of liquid metal two-phase systems since the 1970s. In the present paper we summarize the important findings obtained from our experimental studies for (i) an air-mercury stratified flow in a horizontal rectangular channel, (ii) a helium-lithium annular mist flow in a horizontal rectangular channel, (iii) the mercury pool boiling on a horizontal surface, and (iv) air-mercury upward flows in a vertical circular ...

1995-03-01

304

Studies on magnetohydrodynamic flow characteristics and heat transfer of liquid metal two-phase flow cooling systems for a magnetically confined fusion reactor  

International Nuclear Information System (INIS)

Liquid metal cooling for the first wall and blanket of a magnetic confinement fusion reactor has various advantages. However, it has the disadvantages of large magnetohydrodynamic pressure drops and heat transfer deterioration under a strong magnetic field. Thus, the present authors have proposed cooling with a helium-lithium annular mist flow as well as the cooling with a liquid metal boiling flow, and as fundamental studies, investigated the effect of a magnetic field on the flow characteristics and heat transfer of liquid metal two-phase systems since the 1970s. In the present paper we summarize the important findings obtained from our experimental studies for (i) an air-mercury stratified flow in a horizontal rectangular channel, (ii) a helium-lithium annular mist flow in a horizontal rectangular channel, (iii) the mercury pool boiling on a horizontal surface, and (iv) air-mercury upward flows in a vertical circular ...

305

Feasibility study for use of the natural convection shutdown heat removal test facility (NSTF) for VHTR water-cooled RCCS shutdown  

International Nuclear Information System (INIS)

In summary, a scaling analysis of a water-cooled Reactor Cavity Cooling System (RCCS) system was performed based on generic information on the RCCS design of PBMR. The analysis demonstrates that the water-cooled RCCS can be simulated at the ANL NSTF facility at a prototypic scale in the lateral direction and about half scale in the vertical direction. Because, by necessity, the scaling is based on a number of approximations, and because no analytical information is available on the performance of a reference water-cooled RCCS, the scaling analysis presented here needs to be 'validated' by analysis of the steady state and transient performance of a reference water-cooled RCCS design. The analysis of the RCCS performance by CFD and system codes presents a number of challenges including: strong 3-D effects in the cavity and the RCCS tubes; simulation of turbulence in flows characterized by natural circulation, high Rayleigh ...

306

Augmentation of radiative heat transfer in an infinite cylindrical pipe enclosing a participating gas  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to identify the radiative heat transfer augmentation by a coaxial cylinder introduced in the infinite cylindrical pipe enclosing a participating gas. The gas is either a mixture of water vapor and carbon dioxide or gray. The gas is assumed to be homogeneous at a constant temperature, and has a refractive index of unity. All of the surfaces are opaque and gray, diffusely emitting and reflecting at a constant temperature. The effect of system diameter, diameter ratio, wall emittances, gas and surface temperatures, mixture component on heat transfer augmentation are studied by using the zone method with participating gas radiative properties evaluated from the weighted sum of gray gases model. From the radiative equilibrium condition, the installed wall temperature is formulated and calculated by the iteration method. If the medium is a gray gas, the augmentation observed are negligible. For the ...

1992-10-01

307

Requirements, design and development of a latent heat store for use in vehicles; Anforderungen, Konzeption und Entwicklung eines Latentwaermespeichers fuer den Kraftfahrzeugeinsatz  

Energy Technology Data Exchange (ETDEWEB)

With the development of the latent heat store and its inclusion in the conventional heating control of cars, success has been achieved both in increasing comfort and in making an important contribution to safety of driving. Great store is set in development of the system on its environmental friendliness, for example by the thorough use of environmentally friendly and reusable materials. This also means the use of clean materials. It was shown that the latent heat store (apart from the aspects of comfort and safety of driving) can also make a contribution to saving fuel and reducing the exhaust gas. The sum total of the advantages makes it clear that the latent heat store introduced here is a very environmentally friendly system with multi-functional properties. (orig.) [Deutsch] Mit der Entwicklung des Latentwaermespeichers und seiner Einbindung in die ...

1994-12-31

308

Design and performance of radioisotope space power systems based on OSC multitube AMTEC converter designs  

Energy Technology Data Exchange (ETDEWEB)

This paper extends the analytical procedure described in another paper in these proceedings to analyze a variety of compact and light-weight OSC-designed radioisotope-heated generators. Those generators employed General Purpose Heat Source (GPHS) modules and a converter containing sixteen AMTEC cells of OSC`s revised five-tube design with enhanced cell wall reflectivity described in a companion paper in these proceedings. OSC found that the performance of the generator is primarily a function of the thermal insulation between the outside of the generator`s 16 cells and the inside of its wall. After examining a variety of insulation options, it was found that the generator`s performance is optimized by employing a hybrid insulation system, in which the space between the cells is filled with fibrous Min-K insulation, and the generator walls are lined with tapered (i.e., graded-length) multifoil insulation. The OSC design ...

1997-12-31

309

Design and performance of a solar-powered air-conditioning system in a green building  

Energy Technology Data Exchange (ETDEWEB)

A solar-powered adsorption air-conditioning system was designed and installed in the green building of Shanghai Research Institute of Building Science. The system contained 150 m{sup 2} solar collectors and two adsorption chillers with nominal refrigeration capacity of 8.5 kW. Based on performance characteristics of the adsorption chiller, the operation mode of the solar-powered air-conditioning system was optimized by maintaining a phase shift of 540 s between the two adsorption chillers. Thereafter, the whole system realized stable operation by the balance of heat consumption and refrigeration output. From June to August of 2005, the solar-powered air-conditioning system continuously ran between 9:00 and 17:00. The operation performance of the system under representative working condition showed that the average refrigeration output of the ...

2008-05-15

310

Isothermal heat measurements of TBP-nitric acid solutions  

Energy Technology Data Exchange (ETDEWEB)

Net heats of reaction were measured in an isothermal calorimeter for both single phase (organic) and two phase (organic and aqueous) TBP/HNO{sub 3} reacting solutions at temperatures above 100 C. The oxidation rate constant was determined to be 5.4E-4 min{sup {minus}1} at 110 C for an open ``vented`` system as compared to 1.33 E-3 min{sup {minus}1} in the closed system. The heat released per unit material oxidized was also reduced. The oxidation in both phases was found to be first order in nitric acid and pseudo-zero order in butylnitrate and water. The hydrolysis (esterification) rate constant determined by Nichols` (1.33E-3 min{sup {minus}1}) fit the experimental data from this work well. Forced evaporation of the volatile components by the product gases from oxidation resulted in a cooling mechanism which more than balanced the heat from the oxidation reaction in the two-phased ...

1994-12-16

311

Space power systems prelaunch integration  

International Nuclear Information System (INIS)

The sequence of events from the assembly of a space nuclear power system to its integration in the Space Shuttle Transportation System (STS) is considered. First, the sequence followed for SNAP-10A, the only free world space reactor electric power system ever launched and operated in space, is reviewed. Before shipment, the SNAP-10A reactor was raised to operating temperature using electrically supplied heat and operated at low power for control calibration. Next we discuss shipment to the launch site, a phase that is critical because of the potential for various accidents. Once the power system arrives at the launch site, the processing sequence is performed. This sequence includes checkout, mating with the payload or upper stage launch vehicle, and integration into the STS.

312

Development of barcode system for internal dose monitoring  

International Nuclear Information System (INIS)

In Tarapur Atomic Power Station unit-3 and 4, which is 540 MWe pressurized heavy water reactor, tritium is produced in primary heat transport system and moderator system. Tritium is a major contributor to the internal dose. Internal dose contributes about 30% of the collective dose. Internal dose monitoring and its control are important to control the collective dose. Estimation of internal dose is done by analysis of bioassay samples of radiation workers. In a month, about 7000 bioassay samples are analysed for the internal dose assessment during normal operation, and about 12000 during the biennial shut down of the reactor. To enhance the sample preparation and counting performance, minimize the entry errors and reduce the processing time, barcode based label generation system was developed for the internal dose monitoring. This paper discusses about the use of barcode system in ...

2008-11-19

313

Use of geothermal heat for sugar refining in Imperial County. Final report, Phase I  

Energy Technology Data Exchange (ETDEWEB)

The objective of the three-phase Holly Sugar Geothermal Project was to replace fossil fuels with geothermal energy for sugar beet processing at the Holly Sugar plant located in Brawley, California, in a technically straightforward, economically sound and environmentally acceptable manner. The first phase of the project, discussed in this final report, encompassed the design and analysis of a geothermal industrial heat system for Holly Sugar and addresses: (1) assessment of the geothermal resource; (2) development of a preliminary system design; (3) analysis and publication of an environmental analysis and monitoring report; (4) preliminary economic analyses; (5) dissemination of project related information; and (6) the development of a proposal for the follow-on phases.

1980-12-01

314

Turbines for the turn of the century  

Energy Technology Data Exchange (ETDEWEB)

This article describes how a natural gas-fired combined cycle with increased firing temperature, reduced cooling air usage, improved component efficiencies, and cycle enhancements could achieve a lower heating value plant efficiency of greater than 60%. Today's gas turbine systems feature high fuel-to-electricity efficiencies. Efficiencies, on a lower-heating-value (LHV) basis, for large natural gas-fired combined-cycle systems for the utility market have been demonstrated at 54%. Even though manufacturers will make improvements in the 1990s, efficiency levels will reach a plateau. Cycle innovations and gas turbine design changes will achieve LHV efficiencies in the 60% range for natural gas-fired utility machines.

1994-06-01

315

Spray, combustion, and heat transfer studies in a Ricardo hydra direct-injection diesel engine  

Energy Technology Data Exchange (ETDEWEB)

The spray and combustion development in a single-cylinder, direct-injection diesel engine equipped with optical access was examined using a number of complementary techniques. A laser imaging system, based around a pulsed copper-vapour laser synchronised to an intensified CCD camera, was used to obtain images of the four fuel sprays prior to combustion, and to determine the tip penetration of each spray as a function of crankangle. The surface heat flux to the wall of the piston bowl was measured by placing a fast-response thermocouple at the impingement point of one of the sprays, and a two-colour imaging system was used to obtain digital images of the flame temperature and equivalent soot distribution in the cylinder. (author)

1996-12-31

316

Performance evaluation of low heat rejection engines  

Energy Technology Data Exchange (ETDEWEB)

Improving the performance of the Chinese B135 six-cylinder direct injection turbocharged and turbocompounded Low Heat Rejection Engine (LHRE) was based on experimental and analytical studies. The studies were primarily applied on a B1135 single-cylinder LHR engine and a conventional water-cooled B1135 single-cylinder engine. Performance of the B1135 LHRE was worse than that of the conventional B1135 due to a deterioration in the combustion process of the B1135 LHRE. The combustion process was improved and the fuel injection system was redesigned and applied to the B135 six-cylinder LHRE. The new design improved the performance of the LHRE and better fuel economy was realized by the thermal energy recovered from the exhaust gases by the turbocompounding system.

1994-10-01

317

Nitrogen doping into titanium dioxide by the sol?gel method using nitric acid  

British Library Electronic Table of Contents (United Kingdom)

N-doped TiO2 has been prepared by use of sol?gel systems containing titanium alkoxide, with nitric acid as the nitrogen source. The time needed for gelation of the systems was drastically reduced by ultrasonic irradiation. The peaks assigned to the nitrate and nitrous ions were observed by FT-IR measurement during the sol?gel reaction. The N-doping was confirmed by the observation of N?O peaks in the XPS spectrum of the sample heated at 400??C. The nitrate ion acted as an oxidizer of the ethanol solvent and titanium species. The TiO2 became doped with nitrogen oxide species as a result of reduction of nitrate ion incorporated into the dried gel samples. These results indicated that the added nitric acid was reduced during the sol?gel transition and heating process, and the resulting NO spe...

2011-01-01

318

Gas Appliance Technology Center: Annual report, January-December 1986  

Energy Technology Data Exchange (ETDEWEB)

The report reviews the activity during the fourth year of Gas Research Institute's Gas Appliance Technology Center program. Work on gas appliances involved a conceptual table-top multi-function oven, development of an indirect-fired conveyor oven, and performance comparisons of smooth cooktops. Performance-evaluation methods for commercial ovens were evaluated. Design improvements were made to a direct-fired conveyor oven and a pulse-combustion deep-fat fryer. Performance of common vents were studied, and a device was designed to allow incorporation of appliances with positive vent pressures into such systems. Standards-related work included draft-hood capacities, flexible corrugated-connector corrosion, and sediment trap efficiencies. Heating-related work comprised conceptual design of a vented baseboard heater and a centralized heat-transfer fluid system.

1987-08-01

319

Design and optimization of thermoacoustic devices  

International Nuclear Information System (INIS)

Thermoacoustics deals with the conversion of heat energy into sound energy and vice versa. It is a new and emerging technology which has a strong potential towards the development of sustainable and renewable energy systems by utilizing waste heat or solar energy. Although simple to fabricate, the designing of thermoacoustic devices is very challenging. In the present study, a comprehensive design and optimization algorithm is developed for designing thermoacoustic devices. The unique feature of the present algorithm is its ability to design thermoacoustically-driven thermoacoustic refrigerators that can serve as sustainable refrigeration systems. In addition, new features based on the energy balance are also included to design individual thermoacoustic engines and acoustically-driven thermoacoustic refrigerators. As a case study, a thermoacoustically-driven thermoacoustic refrigerator has been designed ...

2008-12-01

320

Safety significance of ATR passive safety response attributes  

International Nuclear Information System (INIS)

The Advanced Test Reactor (ATR) at the Idaho National Engineering Laboratory was designed with some passive safety response attributes which contribute to the safety of the facility. The three passive safety attributes being evaluated in the paper are: 1) In-core and in-vessel natural convection cooling, 2) a passive heat sink capability of the ATR primary coolant system (PCS) for the transfer of decay power from the uninsulated piping to the confinement, and 3) gravity feed of emergency coolant makeup. The safety significance of the ATR passive safety response attributes is that the reactor can passively respond to most transients, given a reactor scram, to provide adequate decay power removal and a significant time for operator action should the normal active heat removal systems and their backup systems both fail. The ATR Interim Level 1 Probabilistic Risk Assessment (PRA) models ...

1990-03-01

321

Theoretical investigations on improving performance of cooling systems for fuel cell vehicles; Theoretische Untersuchungen zur Kuehlleistungssteigerung durch innovative Kuehlsysteme fuer Brennstoffzellen-Elektrofahrzeuge  

Energy Technology Data Exchange (ETDEWEB)

In this work theoretical investigations are carried out for cooling systems, which are used in fuel cell vehicles. This work focuses mainly on the capability of increasing the heat rejection rate by using new alternative cooling systems and by improving the conventional cooling system. Fuel cell vehicles have a higher demand of heat rejection to the ambient than comparable vehicles with combustion engine. The performance of conventional liquid cooling systems, especially at high loads and high ambient temperatures, is often not sufficient anymore. Hence, cooling systems with improved performance are necessary for fuel cell vehicles. The investigations in this work are based on DaimlerChrysler's ''A-Class'' having a PEM-Fuel Cell system integrated. Specific computational models ...

2008-04-01

322

Energy storage for hybrid remote power systems  

Energy Technology Data Exchange (ETDEWEB)

Energy storage can be a cost-effective component of hybrid remote power systems. Storage serves the special role of taking advantage of intermittent renewable power sources. Traditionally this role has been played by lead-acid batteries, which have high life-cycle costs and pose special disposal problems. Hydrogen or zinc-air storage technologies can reduce life-cycle costs and environmental impacts. Using projected data for advanced energy storage technologies, LLNL ran an optimization for a hypothetical Arctic community with a reasonable wind resource (average wind speed 8 m/s). These simulations showed the life-cycle annualized cost of the total energy system (electric plus space heating) might be reduced by nearly 40% simply by adding wind power to the diesel system. An additional 20 to 40% of the wind-diesel cost might be saved by adding hydrogen storage or zinc-air fuel cells to the ...

1998-03-01

323

Users' guide on socket heat fusion joining of polyethylene gas pipes. Volume 1. Topical report, September 1989-September 1990  

Energy Technology Data Exchange (ETDEWEB)

The integrity of a pipeline system is determined by its weakest links which may be the joints. Heat fusion is the most common method for joining gas distribution polyethylene (PE) piping. There are procedural, thermal, and mechanical aspects of making fusion joints. Acceptable procedural aspects, such as heater calibration and cleanliness, can be assured by rigorous training and certification of the operators. Thermal and mechanical aspects consist of specifying joining conditions such as the heater temperature, heating time, and joining pressure. In the absence of procedural errors, the strength of a fusion joint should depend on the pipe material, pipe dimensions, and the thermal and mechanical joining conditions. Socket heat fusion was studied both experimentally and analytically to determine how the strength of the joint varied with the conditions under which it was made. The standard tensile impact ...

1991-03-01

324

Technical reference on socket heat fusion joining of polyethylene gas pipes. Volume 2. Topical Report, September 1989-September 1990  

Energy Technology Data Exchange (ETDEWEB)

The integrity of a pipeline system is determined by its weakest links which may be the joints. Heat fusion is the most common method for joining gas distribution polyethylene (PE) piping. There are procedural, thermal, and mechanical aspects of making fusion joints. Acceptable procedural aspects, such as heater calibration and cleanliness, can be assured by rigorous training and certification of the operators. Thermal and mechanical aspects consist of specifying joining conditions such as the heater temperature, heating time, and joining pressure. In the absence of procedural errors, the strength of a fusion joint should depend on the pipe material, pipe dimensions, and the thermal and mechanical joining conditions. Socket heat fusion was studied both experimentally and analytically to determine how the strength of the joint varied with the conditions under which it was made. The standard tensile impact ...

1991-03-01

325

Experimental study on heat transfer augmentation for high heat flux removal in rib-roughened narrow channels  

International Nuclear Information System (INIS)

Frictional pressure drop and heat transfer performance in a very narrow rectangular channel having one-sided constant heat flux and repeated-ribs were studied experimentally for turbulent water flows. Their empirical correlations were derived for designing target cooling channels to remove high heat flux generated at target plates in a high-intensity proton accelerator system. The rib pitch-to-height ratios (p/k) were 10 and 20 while holding the rib height constant at 0.2 mm, the Reynolds number (Re) from 2,400 to 98,500 under different channel heights (H) of 1.2 mm and 3.2 mm, the rib height-to-channel equivalent diameter ratio (k/D_e) of 0.088 and 0.036, respectively. The results show that the rib-roughened surface augments heat transfer by about 2-2.5 times compared with the smooth surface at the expense of around 2.5 times higher frictional pressure drop under a range of ...

1998-09-01

326

IECEC '87; Proceedings of the Twenty-second Intersociety Energy Conversion Engineering Conference, Philadelphia, PA, Aug. 10-14, 1987. Volumes 1, 2, 3, and 4  

International Nuclear Information System (INIS)

Papers are presented on space power requirements and issues, space photovoltaic systems, space solar dynamic systems, space thermal systems, manned and unmanned space power systems, thermionics, and thermoelectrics. Also considered are high power devices for space power systems, high power conversion for space power systems, 1-10 kWe nuclear space power sources, 100-kW class nuclear power concepts, space reactor safety, and multimegawatt space nuclear power systems. Other topics include space power systems automation, space kilovolt technology, space power electronics, space lithium and nickel-cadmium batteries, lithium sodium storage, and space fuel cells. Papers are also presented on space nickel hydrogen batteries, alternative energy concepts and fuels, fuel cell technology, flow batteries, high-temperature batteries, ...

1987-08-10

327

Test-bed for compact ventilation units; Pruefstand fuer Kompaktlueftungsgeraete fuer Komfortlueftung  

Energy Technology Data Exchange (ETDEWEB)

This comprehensive, illustrated report for the Swiss Federal Office of Energy (SFOE) by the University of Applied Sciences in Lucerne, Switzerland takes a look at the testing facility at the university that is used to test compact ventilation systems. These feature heat-recovery and return-air heat-pumps and are used in housing built to low energy-consumption standards such as the Swiss 'Minergie' and 'Minergie-P' standards. The primary goal is a technically comprehensive testing programme for compact ventilation units with heat recovery and heat pumps, which can nevertheless be carried out at reasonable cost. In addition to thermal and flow measurements, acoustic measurements are also carried out. The authors quote that the overall assessment provided can also include service and maintenance, materials used and possible problems with thermal ...

2005-12-15

328

Shallow hydrothermal regime of the East Brawley and Glamis known geothermal resource areas, Salton Trough, California  

Energy Technology Data Exchange (ETDEWEB)

Thermal gradients and thermal conductivities were obtained in real time using an in situ heat-flow technique in 15 shallow (90 to 150 m) wells drilled between Brawley and Glamis in the Imperial Valley, Southern California. The in situ measurements were supplemented by follow-up conventional temperature logs in seven of the wells and by laboratory measurements of thermal conductivity on drill cuttings. The deltaic sedimentary material comprising the upper approx. 100 m of the Salton Trough generally is poorly sorted and high in quartz resulting in quite high thermal conductivities (averaging 2.0 Wm/sup -1/ K/sup -1/ as opposed to 1.2 to 1.7 for typical alluvium). A broad heat-flow anomaly with maximum of about 200 mWm/sup -2/ (approx. 5 HFU) is centered between Glamis and East Brawley and is superimposed on a regional heat-flow high in excess of 100 mWm/sup -2/ (> 2.5 HFU). The heat-flow high ...

1981-01-01

329

Microclimatic conditions at the external surface of building envelopes  

Energy Technology Data Exchange (ETDEWEB)

The project is described, the motivation for the research and the microclimate is defined in relation to both building physics research and applications. Air temperatur, air humidity, solar radiation and air velocity are briefly considered, whilst driving rain and long-wave radiation are described in more detail. Convective heat transfer and surface coefficients are discussed, although they are not microclimatic factors, merely resulting from combinations of such factors. They are included as they are important in relation to transfer of heat and moisture at the surface of the building envelope. Driving rain measurement is the main area of interest, including development of measurement equipment. Long-wave irradiation is measured and compared with empirical formulae from the literature. Window convection heat transfer is another main area of interest. Nocturnal convective heat transfer from a double ...

1998-12-31

330

Hydrodynamic studies of post dryout two-phase downflow in narrow channels  

Energy Technology Data Exchange (ETDEWEB)

An experimental study of the hydrodynamics of a narrow channel was performed in order to obtain the heat transfer mechanisms and influences contributing to the flow regime transition from inverted annular to inverted slug flows for post dryout downflow. The experimental series consisted of both adiabatic and diabatic visualization tests over a wide range of fluid and thermal parameters. The system inlet gas velocities ranged from 0 to 14 meters per second while the inlet fluid velocities ranged from 1 to 3 meters per second. Full extent visualization of the flow regime was possible due to a quartz tube in tube construction with a clear heating fluid. Constant temperature heating of the freon was accomplished at bulk fluid temperatures above the critical heat flux temperature. For each hydrodynamic flow condition, one to three minuets of VHS-video filming was performed to acquire ...

1995-07-01

331

Heat transfer augmentation due to surface radiative exchange effect of internal fins in an annulus  

International Nuclear Information System (INIS)

Heat transfer augmentation due to surface radiation in an annulus with fins was investigated both theoretically and experimentally for fully developed laminar flow. The system considered in the present study was an array of axially internal and straight fins attached to the outer tube wall. Analytical solutions were given for 4, 8, 16, 24, 32 fins and for the ratios of the fin height to the passage clearance, 0, 0.2, 0.4, 0.5, 0.6, 0.8. The experiments were performed with air as the working fluid for radius ratio of 1.45, 16 fins and for Reynolds numbers ranging from 500 to 2000. The numerically predicted results of the convective/radiative heat transfer for the present case were in good agreement with the experimental data. It was found that the heat transfer augmentation coefficient attained a maximum value of 1.45 for 32 fins and for a dimensionless fin height of 0.65.

1987-08-01

332

Future view of ceramics low heat rejection engines; Ceramics shanetsugata engine no shorai  

Energy Technology Data Exchange (ETDEWEB)

Resulting of the remarkably growth on economical development in each countries of Asia, ceramics low heat rejection engines are paid attention as a technique corresponding with the third oil shock which is presumed in near future. On the other hand, in order to construct the low heat rejection engines, using the quite different property materials from metals which called ceramics, it is necessary to determine design and combustion method fitted to the feature of this different kind materials. Though the development of ceramics low heat rejection engines have been given up in the world, recently, the development of ceramics engines is again required for the purpose of realizing an engine with low fuel consumption. Authors have successfully solved the problems, such as the disuse of cooling system, the improvement of combustion to reduce fuel consumption and exhaust emissions, and the realization of ...

1998-01-01

333

Cross flow boiling in tube bundles  

Science.gov (United States)

This report contains two main subjects. One is the newly started investigation of cross flow boiling in tube bundles. The heat transfer information at this condition is of significant importance to horizontal steam generator design. The other one is the continuation of the research on boiling heat transfer in confined spaces. The research on cross flow boiling in tube bundles has been started. The Freon loop has been modified for higher flow and higher two phase quality. The test section design is finished and is under fabrication presently. The new instrumentation system is also established. The test matrix has been planned. The research on boiling in confined spaces proceeds steadily. This problem is of great importance to the boiling induced corrosion in the steam generator crevices between the tube and the support plate. In the report of 1981, detailed results were presented for analysis of single phase flow, two phase ...

1982-10-01

334

Combined cycle power plant with integrated low temperature heat (LOTHECO)  

International Nuclear Information System (INIS)

The major driver to enhance the efficiency of the simple gas turbine cycle has been the increase in process conditions through advancements in materials and cooling methods. Thermodynamic cycle developments or cycle integration are among the possible ways to further enhance performance. The current paper presents the possibilities and advantages from the LOTHECO natural gas-fired combined cycle concept. In the LOTHECO cycle, low-temperature waste heat or solar heat is used for the evaporation of injected water droplets in the compressed air entering the gas turbine's combustion chamber. Following a description of this innovative cycle, its advantages are demonstrated by comparison between different gas turbine power generation systems for small and large-scale applications, including thermodynamic and economic analysis. A commercial gas turbine (ALSTOM GT10C) has been selected and computed with the heat ...

2004-08-01

335

Solar hybrid systems in a residential estate of terraced houses near the Wannsee railway in Berlin; Solare Hybridsysteme in einer Reihenhaus-Wohnanlage an der Wannseebahn in Berlin  

Energy Technology Data Exchange (ETDEWEB)

The aim of the study was to establish by means of a measuring programme how much energy for space heating can be saved by the installed hybrid system. Further, experience with the systems was to be gathered under practical use conditions. As user behaviour can influence space heating energy consumption to an extent having several times the effect of the contribution of the hybrid system, a fact that is also reported in literature, it is not sufficient to measure only space heating energy consumption. So, a unit in one of the terraced houses was scrupulously measured. In the three other terraced houses, only space heating energy consumption was measured.- This final report contains not only a description of the concepts of the buildings and hybrid system but also the energy consumptions measured, and detailed analyses of ...

1997-08-31

336

Comparing Maintenance Costs of Geothermal Heat Pump Systems with other HVAC Systems in Lincoln Public Schools: Repair, Service, and Corrective Actions  

Energy Technology Data Exchange (ETDEWEB)

The Lincoln Public School District, in Lincoln, Nebraska, recently installed vertical-bore geothermal heat pump systems in four, new, elementary schools. Because the district has consistent maintenance records and procedures, it was possible to study repair, service and corrective maintenance requests for 20 schools in the district. Each school studied provides cooling to over 70% of its total floor area and uses one of the following heating and cooling systems: vertical-bore geothermal heat pumps (GHPs), air-cooled chiller with gas-fired hot water boiler (ACUGHWB), water-cooled chiller with gas-fired hot water boiler (WCCYGHWB), or water-cooled chiller with gas-fired steam boiler (WCUGSB). Preventative maintenance and capital renewal activities were not included in the available database. GHP schools reported average total costs at 2.13 cents/ft{sup 2}-yr, followed by ACC/GHWB ...

1999-06-19

337

A model for calculation of RCS pressure during reflux boiling under reduced inventory conditions and its assessment against PKL data  

International Nuclear Information System (INIS)

Based on the occurrence of a number of plant incidents during low power and shutdown operating conditions, the Nuclear Regulatory Commission (NRC) has initiated several programs to better quantify risk during these periods. One specific issue of interest is the loss of residual heat removal (RHR) under reduced coolant inventory conditions. This issue is also of interest in the Federal Republic of Germany and an experiment was performed in the integral PKL-3 experimental facility at Siemens-KWU to supply applicable data. Recently, an effort has been undertaken at the Idaho National Engineering Laboratory (INEL) to identify and analyze the important thermal-hydraulic phenomena in pressurized water reactors following loss of vital AC power and consequent loss of the RHR system during reduced inventory operation. The thermal-hydraulic response of a nuclear steam supply system (NSSS) with a closed reactor coolant ...

1991-10-01

338

Fiscal 1996 report on the results of the subsidy operation under the Sunshine Project on the development of a geothermal water use power plant, etc. Development of the binary cycle power plant (development of the measurement while drilling system for geothermal wells); 1996 nendo New Sunshine keikaku hojo jigyo seika hokokusho. Nessui riyo hatsuden plant nado kaihatsu (binary cycle hatsuden plant no kaihatsu (chinetsusei kussakuji kotei joho kenchi system no kaihatsu))  

Energy Technology Data Exchange (ETDEWEB)

The R and D were carried out of a detecting system for measurement of data on the bottom of geothermal well, data transmission and signal processing, and an analysis system for well drilling trajectory control and well assessment while geothermal well drilling based on the data obtained by the detecting system. The paper reported the results of the technology development in fiscal 1996. In the development of the detecting system, improvement/design were conducted on a mud pulse generator constituting sonde, well bottom signal processing equipment, mode switch and inclined information sensor, and the system equivalent to the actual one was manufactured to conduct a running test at high temperature/pressure. Moreover, a test to confirm heat resistance of electronic parts was made for further improvement in heat resistance of the sonde, in ...

1997-03-01

339

Direct denitration and recycling of PFBR MOX liquid waste from dissolution test using microwave heating method  

International Nuclear Information System (INIS)

Full text: Dissolution test (DT) is one of the important specifications of PFBR MOX fuel. It is a macro homogeneity test used to ascertain that the dissolution of spent fuel will be easier during reprocessing. The DT specification limit for PFBR MOX fuel is ? 1.0 wt.% residue of the whole pellet when it is dissolved in HNO3 under reflux conditions. For this test, sintered MOX pellet is dissolved in reflux condition in 60 ml of 12M HNO3 for 10 hours. This test is carried out for each batch and during complete MOX campaign a lot of MOX waste in liquid form is being generated. This liquid waste is in clean form and U and Pu is required to be recovered from the clean waste. Different methods like direct denitration, precipitation and solvent extraction are available but either the product is not of good quality for pelletization or secondary liquid wastes are generated. Microwave denitration is a faster and cleaner method which has different heat transfer mechanism and ...

2010-11-24

340

Heat Transfer Augmentation in a Compact Heat Exchange Pedestal Array.  

Science.gov (United States)

A compact heat exchanger pedestal array for augmenting heat transfer in a machine is disclosed. The compact heat exchanger pedestal array includes a wall having first and second surfaces. The first surface faces a heated flow path and the second surface p...

2004-01-01

341

Study on separation of CO2 gas by TSS (thermal swing sublimation) method. Part 2; TSS ho (Thermal Swing Sublimation: ondo swing shokaho) ni yoru tansan gas bunri no kenkyu. 2  

Energy Technology Data Exchange (ETDEWEB)

TSS (thermal swing sublimation) method was studied which uses vaporization heat and sensible heat of LNG for solidification and separation of CO2 gas in waste gases of LNG-fired combined cycle power generation system. In experiment, the mixed gas composed of CO2, H2O and N2 was used for simulating waste gas of LNG-fired combined cycle power generation systems, and the growth behavior of ice and dry ice was studied for developing dry ice making technology under low-temperature condition. As the experimental result, the following were clarified: various crystal structures depending on cooling temperature, the effect of gas flow rate on peeling of surface precipitated solids, and solidification characteristics of H2O/CO2 mixed gas. The growth rate of precipitated solid film thickness decreased with an increase in gas flow rate, while increased with CO2 concentration. The shape of a dry ice sublimator ...

1997-03-21

342

Prediction of the lifetime behaviour for C/C-SiC tubes as high and ultrahigh temperature heat exchangers (HITHEX) - material characterisation and qualification  

Energy Technology Data Exchange (ETDEWEB)

Heat exchangers for high and ultrahigh temperatures are a need and a precondition to realise high efficient fossil fired power plants based on the so-called Externally Fired Combined Cycle (EFCC) or the Indirect Fired Gas Turbines (IFGT). The main target of both processes is to increase the thermal efficiency of existing power plants by approximately 25% resulting in the same decrease in fuel consumption and, therefore, in the same reduction of CO{sub 2} formation. The main activities of the MPA University of Stuttgart in this project is focused on the characterisation and qualification of the structural material of the ultrahigh temperature heat exchanger (UHTHE) necessary in the above mentioned processes. The influence of the temperature and load on the material behaviour have been analysed by means of tensile tests and creep tests. The effectiveness of different coating systems and the interaction between coating ...

2004-07-01

343

ENGINEERING DEVELOPMENT OF COAL-FIRED HIGH-PERFORMANCE POWER SYSTEMS  

Energy Technology Data Exchange (ETDEWEB)

A High Performance Power System (HIPPS) is being developed. This system is a coal-fired, combined cycle plant with indirect heating of gas turbine air. Foster Wheeler Development Corporation and a team consisting of Foster Wheeler Energy Corporation, Bechtel Corporation, University of Tennessee Space Institute and Westinghouse Electric Corporation are developing this system. In Phase 1 of the project, a conceptual design of a commercial plant was developed. Technical and economic analyses indicated that the plant would meet the goals of the project which include a 47 percent efficiency (HHV) and a 10 percent lower cost of electricity than an equivalent size PC plant. The concept uses a pyrolyzation process to convert coal into fuel gas and char. The char is fired in a High Temperature Advanced Furnace (HITAF). The HITAF is a pulverized fuel-fired boiler/air heater where steam is generated and gas ...

1998-10-01

344

Summary of research on microbiological processes. International Energy Agency Subtask D, final report  

Energy Technology Data Exchange (ETDEWEB)

Storage of thermal energy in aquifers has obvious benefits of saving energy and decreasing the consumption of fossil fuels. However, aquifer thermal energy storage (ATES), which involves groundwater aquifers as the storage medium for heat or chill, impinges on the environment. A literature review of pertinent microbiology publications (Hicks and Stewart, 1988) identified the potential for the interaction of ATES systems and microbiological processes to create a source of infectious diseases and the potential for damage to the environment. In addition, the review identified a potential for microbiological processes to develop conditions that would interfere with the operation of an ATES system. As a result of this research effort, investigators from Finland, Germany, Switzerland, and the United States have examined several ATES systems in operation and have observed that the ATES ...

1992-09-01

345

Summary of research on microbiological processes  

Energy Technology Data Exchange (ETDEWEB)

Storage of thermal energy in aquifers has obvious benefits of saving energy and decreasing the consumption of fossil fuels. However, aquifer thermal energy storage (ATES), which involves groundwater aquifers as the storage medium for heat or chill, impinges on the environment. A literature review of pertinent microbiology publications (Hicks and Stewart, 1988) identified the potential for the interaction of ATES systems and microbiological processes to create a source of infectious diseases and the potential for damage to the environment. In addition, the review identified a potential for microbiological processes to develop conditions that would interfere with the operation of an ATES system. As a result of this research effort, investigators from Finland, Germany, Switzerland, and the United States have examined several ATES systems in operation and have observed that the ATES ...

1992-09-01

346

Solar thermophotovoltaic (STPV) system with thermal energy storage  

Energy Technology Data Exchange (ETDEWEB)

A solar thermophotovoltaic (STPV) system has both terrestrial and space applications because thermal energy storage can be utilized. Excellent properties (heat of fusion=1800 j/gm and melting temperature=1680 K) make silicon the ideal thermal storage material for an STPV system. Using a one dimensional model with tapering of the silicon storage material, it was found that several hours of running time with modest lengths ({approximately}15 cm) of silicon are possible. Calculated steady-state efficiencies for an STPV system using an Er-YAG selective emitter and ideal photovoltaic (PV) cell model are in the range of 15{percent}{endash}17{percent}. Increasing the taper of the storage material improves both efficiency and power output. {copyright} {ital 1996 American Institute of Physics.}

1996-02-01

347

Physical properties of wood-polyester composites prepared by an electron beam accelerator  

Energy Technology Data Exchange (ETDEWEB)

Polyester WPC (wood-polymer composite) systems are one of the promising materials for multiple uses increasing the mechanical properties, provided that their dimensional stability can be improved. Possibility was pursued for the improvement in the dimensional stability of the polyester WPC systems prepared by electron beam irradiation. The impregnation of the mixture of polyester and monomer into both oven-dried beech veneers and preswollen wood was followed by mutual irradiation process. Polymerization was carried out at total dosage of 6 Mrad to the respective surfaces of samples by an electron beam accelerator, and the reaction was completed by heating at 80 deg C for 24 hr. The dimensions of the samples were measured primarily in the tangential direction, and their dynamic modulus and loss modulus were measured by a Rheovibron DDV-2 and the vibrating reed method. The results and the discussion are given for the reaction ...

1981-01-01

348

Physical properties of wood-polyester composites prepared by an electron beam accelerator  

International Nuclear Information System (INIS)

Polyester WPC (wood-polymer composite) systems are one of the promising materials for multiple uses increasing the mechanical properties, provided that their dimensional stability can be improved. Possibility was pursued for the improvement in the dimensional stability of the polyester WPC systems prepared by electron beam irradiation. The impregnation of the mixture of polyester and monomer into both oven-dried beech veneers and preswollen wood was followed by mutual irradiation process. Polymerization was carried out at total dosage of 6 Mrad to the respective surfaces of samples by an electron beam accelerator, and the reaction was completed by heating at 80 deg C for 24 hr. The dimensions of the samples were measured primarily in the tangential direction, and their dynamic modulus and loss modulus were measured by a Rheovibron DDV-2 and the vibrating reed method. The results and the discussion are given for the reaction ...

1980-09-01

349

High pressure in situ diffraction studies of metal-hydrogen systems  

British Library Electronic Table of Contents (United Kingdom)

''Hybrid'' hydrogen storage, where hydrogen is stored in both the solid material and as a high pressure gas in the void volume of the tank can improve overall system efficiency by up to 50% compared to either compressed hydrogen or solid materials alone. Thermodynamically, high equilibrium hydrogen pressures in metal-hydrogen systems correspond to low enthalpies of hydrogen absorption-desorption. This decreases the calorimetric effects of the hydride formation-decomposition processes which can assist in achieving high rates of heat exchange during hydrogen loading-removing the bottleneck in achieving low charging times and improving overall hydrogen storage efficiency of large hydrogen stores. Two systems with hydrogenation enthalpies close to -20kJ/mol H2 were studied to investigate the h...

2011-01-01

350

Fingerprint testing of contaminated ventilation extract filter systems at Sizewell B  

International Nuclear Information System (INIS)

Sizewell B is Nuclear Electric's latest power station, and the Pressurised Water Reactor (PWR) design on which it is based represents a ''first'' for the UK. One of the integral components of the plant is the heating, ventilation and air-conditioning (HVAC) system, which performs a contamination control and gaseous waste management function for the site. During the commissioning of Sizewell B Power Station the extract systems of the HVAC plant underwent a procedure known as ''fingerprinting''. This entailed the characterisation of the facilities provided to test the filtration plant during its lifetime. The assessment of their adequacy was then used to identify necessary modifications and/or to propose the manner in which future in situ performance testing would be carried out. The paper outlines the basic principles and procedure that was used to ''fingerprint'' test systems during the commissioning of ...

351

Estimation of thermodynamic properties of the ternary molten salt system, LiF-NaF-BeF2, by the modified Peng-Robinson equation  

British Library Electronic Table of Contents (United Kingdom)

The molten salt reactor (MSR), which is one of the generation IV reactors, can meet the demand of transmutation and breeding. The thermodynamic properties of the molten salt system like LiF-NaF-BeF2 influence the design and construction of the fuel salt and coolant in the MSR for the new generation. In this paper, the equation of state of the ternary system 15%LiF-58%NaF-27%BeF2, over the temperature range from 873.15 to 1 073.15 K at one atmosphere pressure, is described using a modified Peng-Robinson (PR) equation. The densities of the ternary system and its components are estimated by this equation directly, and compared with the experimental data. Based on the equation of state, the other thermodynamic properties such as the enthalpy, entropy and heat capacity at constant pressure are ...

2007-01-01

352

Environmental assessment of the potential effects of aquifer thermal energy storage systems on microorganisms in groundwater  

Energy Technology Data Exchange (ETDEWEB)

The primary objective of this study was to evaluate the potential environmental effects (both adverse and beneficials) of aquifer thermal energy storage (ATES) technology pertaining to microbial communities indigenous to subsurface environments (i.e., aquifers) and the propagation, movement, and potential release of pathogenic microorganisms (specifically, Legionella) within ATES systems. Seasonal storage of thermal energy in aquifers shows great promise to reduce peak demand; reduce electric utility load problems; contribute to establishing favorable economics for district heating and cooling systems; and reduce pollution from extraction, refining, and combustion of fossil fuels. However, concerns that the widespread implementation of this technology may have adverse effects on biological systems indigeneous to aquifers, as well as help to propagate and release pathogenic organisms that enter thee ...

1988-03-01

353

Diesel-fueled solid oxide fuel cell auxiliary power units for heavy-duty vehicles  

Energy Technology Data Exchange (ETDEWEB)

This paper explores the potential of solid oxide fuel cells (SOFCS) as 3--10 kW auxiliary power units for trucks and military vehicles operating on diesel fuel. It discusses the requirements and specifications for such units, and the advantages, challenges, and development issues for SOFCS used in this application. Based on system design and analysis, such systems should achieve efficiencies approaching 40% (lower heating value), with a relatively simple system configuration. The major components of such a system are the fuel cell stack, a catalytic autothermal reformer, and a spent gas burner/air preheater. Building an SOFC-based auxiliary power unit is not straightforward, however, and the tasks needed to develop a 3--10 kW brassboard demonstration unit are outlined.

2000-05-15

354

Development of fluidized bed cement sintering technology  

Energy Technology Data Exchange (ETDEWEB)

In the new system presented in this paper, the cement clinker is sintered, not in a rotary kiln, but in two different furnaces: a spouted bed kiln and a fluidized bed kiln. The heat generated in the process of cooling the cement clinker is recovered by a fluidized bed cooler and a packed bed cooler, which are more efficient than the conventional coolers. Compared with the rotary kiln system, the new technology significantly reduces NO{sub x} emissions, appreciably cuts energy consumption, and reduces CO{sub 2} emissions as well. Thus, the new system is an efficient cement sintering system that is friendly to the global environment. In this paper, we describe this new technology as one of the applied technologies at an industrial level that is being developed in the Clean Coal Technology Project, and we present the results from test operations at our pilot plant.

1994-12-31

355

Development of a portable thermophotovoltaic power generator  

Energy Technology Data Exchange (ETDEWEB)

A 150 Watt thermophotovoltaic (TPV) power generator is being developed. The technical approach taken in the design focused on optimizing the integrated performance of the primary subsystems in order to yield high energy conversion efficiency and cost effectiveness. An important aspect of the approach is the use of a selective emitter radiating to a bandgap matched photovoltaic array to minimize thermal and optical recuperation requirements, as well as the non-recoverable heat losses. For the initial prototype system, fibrous ytterbia emitters radiating in a band centered at 980 nm are matched with high efficiency silicon photoconverters. The integrated system includes a dielectric stack filter for optical energy recovery and a ceramic recuperator for thermal energy recovery. The system has been operated with air preheat temperatures up to 1350K. The design of the system and ...

1997-03-01

356

Current drive and heating systems based on high-energy (1- to 3-MeV) negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a concept for a current drive system based on negative ions with beam energy > 1 MeV. Preliminary physics calculations show that the core current necessary for stability enhancement can best be achieved by beams with energy ranging from 1 to 4 MeV. Further study and experiments will better define the optimum energy. Work under way at Oak Ridge National Laboratory (ORNL) and at collaborating institutes in Canada and the Federal Republic of Germany is defining a system, its elements, a configuration and operational scenarios deemed appropriate for such devices as ITER and other future steady-state tokamaks, and the requisite research and development to provide such a system. 7 refs., 2 figs.

1988-01-01

357

The use of supplementary firing in an externally-fired combined cycle power plant  

Energy Technology Data Exchange (ETDEWEB)

The most developed systems for the generation of electricity from coal are the Integrated coal Gasification Combined Cycle (IGCC) and the Pressurized Fluidized Bed Combustion (PFBC) system. They both represent state-of-the-art technology and provide electric power at 41-46% LHV efficiency. However, the high level of complexity leads to lower reliability and higher costs. A simpler system, based on a coal-fired steam boiler integrated with a gas turbine, has been proposed. In such a plant, known as the externally fired combined cycle (EFCC), compressed air is heated indirectly in a heat exchanger located in the coal furnace. The hot air is then expanded in a turbine, and the exhaust is passed on to the coal furnace as preheated combustion air. Steam produced in the boiler generates additional power in a steam turbine. The exclusion of coal combustion products from the gas turbine ...

1997-12-31

358

The building tomorrow and after..; Le batiment demain et apres-demain..  

Energy Technology Data Exchange (ETDEWEB)

During its jubilee, the French building technical and scientific centre (CSTB) has organized a colloquium about the future tendencies of buildings evolution in the 20 forthcoming years: autonomy in energy production and wastes or effluents management, reduction of water consumption and management of water, hot water production and space heating, bio-sensors for the management of indoor air-quality, control of noise environment using active acoustic systems etc.. (J.S.)

1998-01-01

359

Symplectic Integrators Designed for Simulating Soft Matter  

Science.gov (United States)

Symplectic integrators designed for simulating soft matter at constant temperature and constant pressure (or constant surface tension) are presented. In addition to the well-known merits of symplectic integrators, such as long time stability, these methods allow the estimation of thermal heat production/absorption and thus entropy differences through a simple function of the time scaling factor ?. The relative entropy estimation around crystal-liquid phase transition is given for systems with soft core repulsive potential.

2008-04-01

360

Solar-powered humidification dehumidification desalination system  

Energy Technology Data Exchange (ETDEWEB)

Presented are some preliminary studies made in preparation for the design of a solar powered loop for desalination by humidification - dehumidification process. The studies concentrated on the evaluation of different parameters affecting the performance of the combination of different components in such a loop in the hope of outlining the most decisive factors for the choice or design of solar collectors or heat source. The results presented relate to the performance of two of the most important components in a loop of such purpose, that is: the humidifying and the dehumidifying columns or stacks. 4 refs.

1980-01-01

361

Pumping manual/7th edition  

Energy Technology Data Exchange (ETDEWEB)

This book includes the latest developments and covers pump performance, selection and operations, materials, seals and packings, effective fluid characteristics, filtration, piping systems, economics, valves, instrumentation, automatic controls, power transmission equipment, pump and pipeline heating, and more. An extensive data section contains formulas, charts, symbols, nomographs, and standard specification documents.

1984-01-01

362

Primary side flow distribution of a horizontal steam generator under low flow conditions  

Energy Technology Data Exchange (ETDEWEB)

The presentation deals with the flows on the primary side of a horizontal steam generator under conditions typical to natural circulation cooling of the reactor. The main goal is to analyse the effect of primary flow patterns on the heat transfer capability of the steam generator. Conclusions pertinent to steam generator modelling with system codes are also drawn. (10 refs., 9 figs., 4 tabs.).

1993-12-31

363

Primary side flow distribution of a horizontal steam generator under low flow conditions  

International Nuclear Information System (INIS)

The presentation deals with the flows on the primary side of a horizontal steam generator under conditions typical to natural circulation cooling of the reactor. The main goal is to analyse the effect of primary flow patterns on the heat transfer capability of the steam generator. Conclusions pertinent to steam generator modelling with system codes are also drawn. (10 refs., 9 figs., 4 tabs.).

1992-09-29

364

Growth model and on-line measurement of pitting corrosion on carbon steel  

Energy Technology Data Exchange (ETDEWEB)

A growth model of pitting corrosion of carbon steel in cooling water systems was developed on microscopic observations of pits and electrochemical studies. Results of pitting corrosion measurements in laboratory and field conditions with the model, using a newly developed electrochemical device, are discussed. For an actual heat exchanger up to a year operation, the values of pitting depth estimated were in good agreement with the measured values.

1996-12-01

365

Environmental effects and energy efficiency in building design - a green building approach. Pt. 1. Energy efficiency techniques  

Energy Technology Data Exchange (ETDEWEB)

A research report describes the energy efficiency techniques to be employed in designing a building which is ``green``. Topics covered include building fabric performance, ventilation and infiltration, passive solar design, heating systems and controls, hot and cold water provision, lighting and electrical appliances. (UK)

1993-12-31

366

Drilling on the basis of reliable data. Geothermal exploration; Bohren nach verlaesslichen Planungsdaten. Geothermie  

Energy Technology Data Exchange (ETDEWEB)

Geothermal heat pump systems necessitate a comprehensive approach to geology and building facilities in order to be energetically useful and efficient. Cooperation with geothermal experts should be sought at an early projecting stage in order to obtain reliable data. Geothermal data and the technical facilities of the building must be matched for the project to be both effective and efficient. (orig.)

2008-01-15

367

Direct measurements of secondary water inventory of steam generator PGV-213 in operation  

Energy Technology Data Exchange (ETDEWEB)

Results of weight measurement of PGV-213 steam generator during filling in, heating-up and power increase are described. Special measurement system based on stress gauges has been developed. Method of derivation of secondary water inventory is described. Comparison of the data for two steam generators prove accuracy of the measurements. (orig.). 1 refs.

1997-12-31

368

Change of crystal field in the Er(Ni,Cu)Al system  

Energy Technology Data Exchange (ETDEWEB)

The ErNi{sub 1-} {sub x} Cu {sub x} Al compounds crystallize all in the hexagonal ZrNiAl-type structure. The concentration dependence of lattice constants shows a discontinuity between x=0.5 and 0.6. This structural change has no primary impact on the magnetic order in this series, but influences the crystal field. The lower part of the crystal-field energy-level schemes has been estimated from the specific-heat data.

2007-09-15

369

Change of crystal field in the Er(Ni,Cu)Al system  

International Nuclear Information System (INIS)

The ErNi_1_- _x Cu _x Al compounds crystallize all in the hexagonal ZrNiAl-type structure. The concentration dependence of lattice constants shows a discontinuity between x=0.5 and 0.6. This structural change has no primary impact on the magnetic order in this series, but influences the crystal field. The lower part of the crystal-field energy-level schemes has been estimated from the specific-heat data.

2007-09-01

370

CRC handbook of physical properties of rocks. Volume III  

Energy Technology Data Exchange (ETDEWEB)

This book presents topics on: Density of rocks and minerals, includes histograms of density ranges; elastic constants of minerals, elastic moduli, thermal properties; inelastic properties, strength and rheology for rocks and minerals, rock mechanics and friction, and stress-strain relations; radioactivity, decay constants and heat production of isotope systems in geology; seismic attenuation, in rocks, minerals, and the earth, with application to oil exploration and terrestrial studies; and index.

1984-01-01

371

CAPSULE REPORT: BAHCO FLUE GAS DESULFURIZATION AND PARTICULATE REMOVAL SYSTEM  

Science.gov (United States)

This capsule report describes a Research-Cottrell/Bahco scrubber module for sulfur dioxide and particulate emission control located at the central heat plant of Rickenbacker Air Force Base. he report also describes flue gas desulfurization technology using any fuel, including hig...

372

A study of passive and inherent safety design concepts for advanced light= water reactors  

Energy Technology Data Exchange (ETDEWEB)

The five thermal-hydraulic concepts chosen for conceptual study of advanced PWR systems have been studied as follows: (1) Critical Heat Flux in passive PWR Conditions: review of previous works (various of correlations, analysis of parametric trends) on CHF, assessment and improvement of CHF prediction models for round tubes, development of the prediction model on bundle CHF with considering the correction factor calculated from the tube data base, design and construction of the intermediate-pressure CHF experimental loop, extension of CHF data base by performing the experiments at low-flow, and low-quality conditions (2) Passive Cooling Concepts for Concrete Containment Systems: Selection of the external condenser by comparing and reviewing between passive cooling concepts for concrete containment system concepts, survey and review of previous studies (theoretical mechanism of condensation ...

1997-07-01

373

Large Eddy Simulation for Heat Transfer Prediction in a Gas ...  

Science.gov (United States)

... turbine blade heat-transfer and study the heat-transfer augmentation in idealized geometry and its ... responsible for heat transfer augmentation. ...

2007-03-30

375

Sulfuric acid catalysts on heterogel supports  

Energy Technology Data Exchange (ETDEWEB)

Reinforced (heterogel) silicate materials containing an amorphous and a crystalline phase are being used more and more industry. Such systems are energetically unsaturated and therefore promising for use in catalysts. The authors used two reinforced materials as supports: an aluminosilicate containing a zeolite (the cracking catalyst, tseokar) and asbestos-containing aluminosilicate. The active component was introduced by impregnation, and this was followed by heat treatment during which the chemical composition and porous structure were formed. The impregnating mixture consisted of solutions of potassium sulfate and vanadate of the required concentrations. The testing shows that reinforced heterogel systems are promising as support materials for sulfuric acid catalysts.

1985-05-10

376

Renovation of air-conditioning at La Defense; Renovation de la climatisation a La Defense  

Energy Technology Data Exchange (ETDEWEB)

Twenty years after its building, the tertiary sector of La Defense district near Paris has been rehabilitated. The main reason is not only the age and wear of materials but the heating costs, the fire protection regulations, the search for a better air quality and air renewing with less dusts, smells and noise and a controlled moisture. This paper describes first the original installation of the Monge CB 6 office building and then the renovated installation: the central hot and cold air-treatment plant, the variable flow ventilation system, the air extraction and supply system threw the roofs and the pressure and thermal regulation of the installation. (J.S.)

1997-05-01

377

Protective oxides in coal-fired combined cycle power systems  

Energy Technology Data Exchange (ETDEWEB)

In most industrial processes operating at elevated temperatures, protective oxide layers perform a vital duty in protecting the underlying metallic alloys from process gases. Coal-fired combined cycle power generation systems present a number of process conditions in which the properties of the protective oxide layers are particularly important. This paper discusses two of these particular conditions: (1) `erosion/corrosion` of in-bed heat exchanger tubing and (2) thermal cycling of hot gas path components. For both these situations, the desirable properties of protective scales are outlined. The behaviour of scales in practice are highlighted. 33 refs., 6 figs., 2 tabs.

1995-12-31

378

Organometallic Polymer Coatings for Geothermal-Fluid-Sprayed Air-Cooled Condensers: Preprint  

Energy Technology Data Exchange (ETDEWEB)

Researchers are developing polymer-based coating systems to reduce scaling and corrosion of air-cooled condensers that use a geothermal fluid spray for heat transfer augmentation. These coating systems act as barriers to corrosion to protect aluminum fins and steel tubing; they are formulated to resist the strong attachment of scale. Field tests have been done to determine the corrosion and scaling issues related to brine spraying and a promising organometallic polymer has been evaluated in salt spray tests.

2002-08-01

379

Line-focus solar central power system, Phase I. Final report, 29 September 1978 to 30 April 1980. Volume III. Appendices  

Energy Technology Data Exchange (ETDEWEB)

The conceptual design, parametric analysis, cost and performance analysis, and commercial assessment of a 100-MWe line-focus solar central receiver power plant are reported. This volume contains the appendices: (a) methods of determination of molten salt heat-transfer coefficients and tube-wall temperatures, (b) inputs for STEAEC programs, (c) description of system analysis computer program, (d) receiver analysis program, and (e) heliostat production plan and design methodology. (WHK)

1980-04-01

380

Line-focus solar central power system, Phase I. Final report, 29 September 1978 to 30 April 1980. Volume II. Text  

Energy Technology Data Exchange (ETDEWEB)

The conceptual design, parametric analysis, cost and performance analysis, and a commercial assessment of a 100-MWe high-temperature line-focus central power system are presented. Parametric analyses and conceptual design of the heliostat subsystem, receiver subsystem, heat transport subsystem, energy storage subsystem, electrical power generating subsystem, and master control subsystem are included. A market analysis and development plan are given. (WHK)

1980-04-01

381

Freeze protection valve and system  

Energy Technology Data Exchange (ETDEWEB)

The present invention is a device for a solar heating system having a solar collector, a storage tank connected to the solar collector, a pump for circulating liquid from the tank to the solar collector, a supply of liquid at a temperature above freezing and a connection from the supply of liquid to the solar collector for replacing any liquid lost from said solar collector. The device comprises a sensor for sensing the temperature of liquid in the solar collector, and a valve for bleeding liquid from the solar collector when the sensed temperature falls below a predetermined minimum whereby cool liquid in the solar collector is automatically replaced by liquid at a temperature above freezing.

1985-12-10

382

Experimental Proof Of Principle For The Link-Up Of A Solid Oxide Fuel Cell With A Counter-Current Wood Gasifier  

Energy Technology Data Exchange (ETDEWEB)

The combination of wood gasification and high temperature fuel cells like solid oxide fuel cells (SOFC) is an interesting approach to achieve high electrical efficiencies (40%) in small scale combined heat and power plants. This combination is called 'Biomass - Integrated Gasification Fuel Cell System' (B-IGFC). The main challenge is the adjustment of the three main components gasification, gas cleaning and fuel cell. In this technology, the first proof of principle by combining a gasifier with a SOFC in a laboratory scale for more than 100 hours was achieved. During this period, no deactivation of the system was found. (author)

2005-03-01

383

Engineering study on steam storage power generation  

International Nuclear Information System (INIS)

Large scale steam storage power generation, one of the new energy storage systems for the future of inflexible electric power sources consisting of nuclear and coal power plants has been studied on the subjects of the systems to be attached to coal and nuclear power units, of the definition of storage efficiency and of the vertical steam storage vessel technology. Steam storage power generation may be hopeful for its higher efficiency similarly defined as of pumped storage plants while high temperature heat storage and the internal structure of large vertical steam storage vessel (accumulator) need to be developed. (author).

1981-01-01

384

Electric power production from the biogas resulting of the sewer treatment: pilot project of the Sewer Treatment Station (ETE) in the Barueri city in the Great Sao Paulo; Producao de energia eletrica a partir do biogas resultante do tratamento de esgoto: projeto piloto na E.T.E. de Barueri na Grande Sao Paulo  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a system for biogas conversion to electric power and heat by using a micro turbine and three Otto cycle engines. The benefit of the energy from a treatment process residue aims the improvement of the global performance of the system, reducing the the emission of the greenhouse gases and contributing to the global energetic efficiency of the sewage treatment station and the basic sanitation in Brazil.

2002-07-01

385

Effects of vaporizer and evaporative-condenser size on geofluid effectiveness and cost of electricity for geothermal binary power plants  

Energy Technology Data Exchange (ETDEWEB)

A special study was conducted to investigate the influences of minimum approach temperature differences occurring in supercritical-heater/vaporizer and evaporative-condenser heat rejection systems on geothermal-electric binary power plant performance and cost of electricity. For the systems investigated optimum pinch points for minimizing cost of electricity were estimated to range from 5 to 7/sup 0/F for the heater vaporizer. The minimum approach of condensing temperature to wet-bulb temperature for evaporative condensers was estimated to be about 30/sup 0/F in order to achieve the lowest cost of electricity.

1983-10-01

386

DKV conference Vol. 26 (1999). No. 4. Session 4; DKV-Tagungsbericht. 26. Jahrgang (1999). Bd. 4. Arbeitsabteilung 4  

Energy Technology Data Exchange (ETDEWEB)

Vol. 4 comprises 23 papers on the following subjects: General aspects (effects in the human/environment systeme); Trends in space HVAC engineering; Heating systems engineering; Air quality and thermal comfort. [German] Der Tagungsband 4 enthaelt 23 Aufsaetze. Sie sind in die folgenden vier Themen-Bloecke aufgeteilt: Allgemeines (Wirkungen in der wahrgenommenen Wirkungssystem: Mensch-Umwelt); Entwicklungen in der Raumlufttechnik; Heizungstechnik; Luftqualitaet und Behaglichkeit. (AKF)

2000-07-01

387

Closed loop air cooling system for combustion turbines  

Energy Technology Data Exchange (ETDEWEB)

Convective cooling of turbine hot parts using a closed loop system is disclosed. Preferably, the present invention is applied to cooling the hot parts of combustion turbine power plants, and the cooling provided permits an increase in the inlet temperature and the concomitant benefits of increased efficiency and output. In preferred embodiments, methods and apparatus are disclosed wherein air is removed from the combustion turbine compressor and delivered to passages internal to one or more of a combustor and turbine hot parts. The air cools the combustor and turbine hot parts via convection and heat is transferred through the surfaces of the combustor and turbine hot parts.

1998-01-01

388

Clean air status report. Statistical analysis of pollution, 1966 through 1982  

Energy Technology Data Exchange (ETDEWEB)

Air pollution abatement measures are being intensified at the moment: Power plants and district heating systems are being retrofitted with high-efficiency desulphurisation and NO/sub 2/ reduction systems, the 3rd amendment of the Clean Air Technical Guide sets more rigid emission limits, and unleaded petrol and catalysts will significantly reduce car exhaust emissions. The author presents pollutant balances from 1966 to 1982 to contradict the popular notion that pollutant emitters formerly failed to take preventive measures.

1986-04-01

389

Thermal energy storage performance of fatty acids as a phase change material  

Energy Technology Data Exchange (ETDEWEB)

Thermal energy storage performance of fatty acids and a eutectic mixture as phase change materials (PCMs) has been investigated experimentally. The selected PCMs for this study were palmitic acid, myristic acid, stearic acid, and a mixture of stearic and myristic acids in eutectic combination ratio of 65.7 wt% myristic acid and 34.3 wt% stearic acid. The PCMs have a melting temperature range of 50.0{sup o}C to 61.20{sup o}C and a latent heat range of 162.0 J/g to 204.5 J/g. The inlet temperature and the mass flow rate of heat transfer fluid (HTF) were selected as experimental parameters to test the thermal energy storage performance of the PCMs. The transition times, temperature range, propagation of the solid-liquid interface, as well as heat flow rate characteristics of the employed cylindrical tube storage system were studied at varied experimental parameters. The experimental results show that the ...

2006-01-21

390

Influence of the fin orientation on the cooling of disc-brakes  

International Nuclear Information System (INIS)

Nowadays, computational fluid dynamics is being applied in many fronts to improve the understanding of the flow and heat transfer behaviour in engineering applications. Unfortunately, there are not so many computational investigations regarding the ventilation and temperature distribution in discs-brakes. In this respect, this study presents a (CFD) analysis is carried out to investigate temperature distributions and flow patterns through disc brakes. The final goal is the development of shapes that optimize heat dissipation rates dictating the stopping capability of disc brakes. High performance discs brakes have a variety of cooling channels and the optimization of these passages is a challenging task for the manufacturing industry. High values of heat transfer coefficients of disc-brake configurations, are the most critical quantities during the design phase of new braking systems. In this context, a ...

2003-05-28

391

Heat transfer characteristics of horizontal steam generators under natural circulation conditions  

Energy Technology Data Exchange (ETDEWEB)

This paper deals with the heat transfer characteristics of horizontal steam generators, particularly under natural circulation (decay heat removal) conditions on the primary side. Special emphasis is on the inherent features of horizontal steam generator behaviour. A mathematical model of the horizontal steam generator primary side is developed and qualitative results are obtained analytically. A computer code, called HSG, is developed to solve the model numerically, and its predictions are compared with experimental data. The code is employed to obtain for VVER 440 steam generators quantitative results concerning the dependence of primary-to-secondary heat transfer efficiency on the primary side flow rate, temperature and secondary level. It turns out that the depletion of the secondary inventory leads to an inherent limitation of the decay energy removal in VVER steam generators. The limitation arises as a consequence of ...

1996-10-01

392

Experimental and theoretical studies of solar steam reforming assisted by molten salts  

Energy Technology Data Exchange (ETDEWEB)

The pathway to hydrogen generation entirely from renewable energy and material sources probably goes by a transitional period with the utilization of hybrid fossil/renewable integrated systems. Solar steam reforming of methane is set in this context, specifically suited for a country like Italy whose actual energy policy is mainly based on the imported NG, but also characterized by convenient solar radiation levels in the Southern Regions. A new solar SMR process is being developed by ENEA, using molten nitrates as solar heat carriers and storage medium at about 550 C. The potential of this process have been proved theoretically by process simulation studies. Engineering and experimental activities aimed to the development of a prototype apparatus are now in progress in ENEA's laboratories. It is remarkable that the developed technology (MS powered SMR) can find interesting impact in the in industrial chemistry wherever it is ...

2010-07-01

393

Comparison between experimental data and numerical modeling for the natural circulation phenomenon  

Energy Technology Data Exchange (ETDEWEB)

There is a crescent interest in the scientific community in the study of natural circulation phenomenon. New generation of compact nuclear reactors uses the natural circulation of the fluid as a system of cooling and of residual heat removal in case of accident or shutdown. The objective of this paper is to present a study through the comparison of experimental data and numerical simulation for the natural circulation phenomenon in one and two-phase flow regime. An experimental circuit built with glass tubes is used for the experiments. Thus, it allows the thermal hydraulic phenomena visualization. There is an electric heater as the heat source, a heat exchanger as the heat sink and an expansion tank to accommodate fluid density excursions. The circuit instrumentation consists of thermocouples and pressure meters to better keep track of the flow and heat ...

2009-07-01

394

A phenomenological model of the thermal hydraulics of convective boiling during the quenching of hot rod bundles  

International Nuclear Information System (INIS)

In this paper, a phenomenological model of the thermal hydraulics of convective boiling in the post-critical-heat-flux (post-CHF) regime is developed and discussed. The model was implemented in the TRAC-PF1/MOD2 computer code (an advanced best-estimate computer program written for the analysis of pressurized water reactor systems). The model was built around the determination of flow regimes downstream of the quench front. The regimes were determined from the flow-regime map suggested by Ishii and his coworkers. Heat transfer in the transition boiling region was formulated as a position-dependent model. The propagation of the CHF point was strongly dependent on the length of the transition boiling region. Wall-to-fluid film boiling heat transfer was considered to consist of two components: first, a wall-to-vapor convective heat-transfer portion and, second, a wall-to-liquid ...

1983-10-14

395

Transient Critical Heat Flux tests on a rod bundle simulating Pressurized Water Reactors  

International Nuclear Information System (INIS)

Transients induced in nuclear power plants from many sources result in one or more fluid conditions changing with time. Fluid conditions of pressure, inlet temperature, inlet flow, or even system power many change separately or in conjunction with each other. The result of the condition change may be one which induces departure from nucleate boiling. An experimental investigation of transient which were intended to achieve Critical Heat Flux was performed at the Heat Transfer Research Facility of Columbia University for Siemens Nuclear Power Corporation. The transients were set up to include broad ranges of flow and pressure conditions near the operating range of pressurized water reactors. Transient events were dominated by varying single conditions and measuring the response of the system and of the rod thermocouples. Because of coupling effects within the test loop, secondary conditions would also ...

396

Thermodynamic model of the gas and steam process with combined heat and power process; Thermodynamisches Modell des GuD-Prozesses mit Kraft-Waerme-Kopplung  

Energy Technology Data Exchange (ETDEWEB)

A whole sequence of the parameters of the combined heat and power system (KWK) is described which enables a comparison between the electricity and heat demand of a consumer and the energy availability through a combined heat and power system. Proceeding from this, a thermodynamic model of a steam and gas process with combined heat and power is introduced which is based on an exergetic balancing of the subsystems of the process. In this way, the varying thermodynamic quality of the energy flows occuring in the process will be taken into consideration so that the results of the model correspond in any case with the second law of thermodynamics. (orig.) [Deutsch] Es wird ein vollstaendiger Satz von Kenngroessen der Kraft-Waerme-Kopplung (KWK) beschrieben, mit dessen Hilfe der Strom- und Waermebedarf eines Verbrauchers mit der Energiebereitstellung durch eine ...

1996-03-01

397

Cooling of nuclear power stations with high temperature reactors and helium turbine cycles  

International Nuclear Information System (INIS)

On nuclear power stations with high temperature reactors and helium turbine cycles (HTR-single circuits) the residual heat from the energy conversion process in the primary and intermediate coolers is removed from cycled gas, helium. Water, which is circulated for safety reasons through a closed circuit, is used for cooling. The primary and intermediate coolers as well as other cooling equipment of the power plant are installed within the reactor building. The heat from the helium turbine cycle is removed to the environment most effectively by natural draught cooling towers. In this way a net plant efficiency of about 40% is attainable. The low quantities of residual heat thereby produced and the high (in comparison with power stations with steam turbine cycles) cooling agent pressure and cooling water reheat pressure in the circulating coolers enable an economically favourable design of the overall 'cold end' to be ...

398

Advanced Binary Geothermal Power Plancts Working Fluid Property Determination and Heat Exchanger Design  

Energy Technology Data Exchange (ETDEWEB)

The performance of binary geothermal power plants can be improved through the proper choice of a working fluid, and optimization of component designs and operating conditions. This paper reviews the investigations at the Idaho National Engineering Laboratory (INEL) which are examining binary cycle performance improvements: for moderate temperature (350 to 400 F) resources with emphasis on how the improvements may be integrated into design of binary cycles. These investigations are examining performance improvements resulting from the supercritical vaporization of mixed hydrocarbon working fluids and achieving countercurrent integral condensation with these fluids, as well as the modification of the turbine inlet state points to achieve supersaturated turbine vapor expansions. For resources where the brine outlet temperature is restricted, the use of turbine exhaust recuperators is examined. The baseline plant used to determine improvements in plant performance (characterized by the ...

1989-03-21

399

Study on core cooling of hybrid safety system for next-generation PWR during LOCA  

International Nuclear Information System (INIS)

Mitsubishi is now developing a next-generation Pressurized Water Reactor (PWR) which has the innovative feature of hybrid safety systems (optimum combination of passive safety system and active safety system) and passive core cooling by horizontal steam generators during Loss of Coolant Accident (LOCA). In order to confirm the capability of this passive core cooling system during LOCAs, the thermal-hydraulic tests of horizontal steam generator and the integral thermal-hydraulic tests simulating the LOCAs were performed. The thermal-hydraulic tests of horizontal steam generator consist of a single tube test and a multi-tubes test. On the basis of these test results, the heat transfer characteristics of steam-water two-phase flow with noncondensable gas along a long horizontal tube is understood and the heat transfer correlation including the effect of ...

1995-04-23

400

Review of fires and fire control methods for nuclear air cleaning systems  

International Nuclear Information System (INIS)

The nuclear power industry has experienced four carbon based adsorbent fires in its history, one was of the Monticello Standby Gas Treatment System and other three were in various off-gas delay beds. Although, some of the latter may not be classified as a full fledged fires. There were a number of experiments performed relating to igniting carbon beds and experiments relating to attempts at extinguishing set fires reported in the literature. Review of these experiments indicates that fire resulting from decay heat of adsorbed radioactive iodine is not justified even under the somewhat unrealistic source terms still in effect. At the same time the non-nuclear chemical industry application of carbon base adsorbents for solvent recovery has resulted in numerous fires and significant property losses. Fire control systems installed in nuclear air cleaning systems in the US consists of water deluge. ...

1987-05-01

401

Research and development of new coal based combined cycle power plant concept  

Energy Technology Data Exchange (ETDEWEB)

Out of concern for the global environment, technologies for coal-fired combined cycle power generation are under development throughout the world today, aiming at highly efficient use of coal. Under these circumstances, the authors and others, with the intention of producing a coal-fired combined cycle power generation system with higher plant efficiency, lower construction cost, and higher reliability than conventional systems, proposed a new gasification combined cycle power generation system that differs from the conventional IGCC system. The authors studied system configuration and conducted elementary research necessary for implementing the system. This report deals with the basic concepts of the system and the results of basic studies carried out to realize of the concepts, including a study on alkali metal vapour concentration in ...

1997-12-31

402

Nuclear reactor closed Brayton cycle power conversion system optimization trends for extra-terrestrial applications  

International Nuclear Information System (INIS)

Extra-terrestrial exploration and development missions of the next century will require reliable, low-mass power generation modules of 100 kW_e and more. These modules will be required to support both fixed-base and manned rover/explorer power needs. Low insolation levels at and beyond Mars and long periods of darkness on the moon make solar conversion less desirable for surface missions. For these missions, a closed Brayton cycle energy conversion system coupled with a reactor heat source is a very attractive approach. The authors conducted parametric studies to assess optimized system design trends for nuclear-Brayton systems as a function of operating environment and user requirements. The inherent design flexibility of the closed Brayton cycle energy conversion system permits ready adaptation of the system to future design constraints. This paper describes a ...

1990-08-12

403

Three-dimensional modeling of heat transport in deep hydrothermal reservoirs  

British Library Electronic Table of Contents (United Kingdom)

The need for alternative energy increases steadily???especially due to the climate change and the limited availability of fossil fuels. Geothermal power uses the intrinsic heat which is stored in the accessible part of the Earth???s crust. Its importance among the renewable energy resources originates from the almost unlimited energy supply of the Earth and its independence from external influences such as seasonal or even daily climatic variability. Nevertheless, there are risks which have to be assessed. From a mathematical point of view there are four building blocks of the characterization of deep geothermal systems: seismic exploration, gravimetry, modeling transport processes, and modeling the stress field. In particular, local depletion poses a significant risk during the industrial...

2011-01-01

404

Thermal and radiation losses in a linear device  

Energy Technology Data Exchange (ETDEWEB)

An analysis is presented of the electron temperature in a linear device which includes the effect of thermal conduction, heat flux limit, radiation, and end plugs. It is found that the thermal conduction and the heat flux limit are dominant in the initial phase of cooling, while the later phase is almost completely controlled by radiation that spatially homogenizes the temperature distribution. In the case of bremsstrahlung, within the frame of the present model, the temperature decays to zero in a finite time. This process takes the form of a cooling wave that moves from the ends of the column to the center. Impurities cause a milder, exponential decay, which is still much faster than the algebraic conduction decay. The thermal effectiveness of the end plugs is described by a convective transfer coefficient h/sub p/. Its scaling law (in terms of the coupled plamsa-plug system) reveals that a very high plug-plasma density ...

1980-11-01

405

The questions of liquid metal two-phase flow modelling in the FBR core channels  

International Nuclear Information System (INIS)

The two-fluid model representation for calculations of two-phase flow characteristics in the FBR fuel pin bundles with liquid metal cooling is presented and analysed. Two conservation equations systems of the mass, momentum and energy have been written for each phase. Components accounted the mass-, momentum- and heat transfer throughout the interface occur in the macro-field equations after the averaging procedure realisation. The pattern map and correlations for two-fluid model in vertical liquid metal flows are presented. The description of processes interphase mass- and heat exchange and interphase friction is determined by the two-phase flow regime. The opportunity of the liquid metal two-phase flow regime definition is analysed. (author)

2000-06-01

406

Some characteristics of a novel direct thermal to optical energy converter medium  

Energy Technology Data Exchange (ETDEWEB)

We have measured some of the optical characteristics of a novel energy conversion medium, over a range of compositions in the system Yb[sub 2]O[sub 3][minus]Al[sub 2]O[sub 3], which we have fabricated by a proprietary process. These specimens have good resistance to thermal shock, are durable, and are mechanically and chemically stable. The integrated emission of light generated by these unoptimized specimens when heated with a propane-air flame and detected with a silicon photodetector ranged up to 1.88 watts/cm[sup 2]. The emission spectrum from these specimens when heated with a propane-air flame and detected with a germanium photodetector shows a narrow band in the vicinity of 1 micron.

1995-01-05

407

Quantitative model of vapor dominated geothermal reservoirs as heat pipes in fractured porous rock  

Science.gov (United States)

We present a numerical model of vapor-dominated reservoirs which is based on the well-known conceptual model of White, Muffler, and Truesdell. Computer simulations show that upon heat recharge at the base, a single phase liquid-dominated geothermal reservoir in fractured rock with low matrix permeability will evolve into a two-phase reservoir with B.P.D. (boiling point-for-depth) pressure and temperature profiles. A rather limited discharge event through cracks in the caprock, involving loss of only a few percent of fluids in place, is sufficient to set the system off to evolve a vapor-dominated state. The attributes of this state are discussed, and some features requiring further clarification are identified. 26 refs., 5 figs.

1985-03-01

408

Multi-Dimensional Analysis for Sodium Hot Pool using MARS-LMR in Steady State  

International Nuclear Information System (INIS)

DBEs (Design Basis Event) of KALIMER-600 (Korea Advanced Liquid Metal Reactor) were analyzed in one dimension by KAERI (Korea Atomic Energy Research Institute). KALIMER-600 is the pool type SFR (Sodium cooled Fast Reactor), thereby the sodium of primary system is prohibited movement to out of a reactor vessel. There are many contacting and including compositions in the sodium hot pool, such as IHX (Intermediate Heat eXchanger), DHX (Decay Heat eXchanger), Pump, UIS (Upper Internal Structure), and core. Moreover, the complex phenomena are occurred in sodium hot pool during steady and transient states. Therefore, the one dimensional analysis is modified to the multi-dimensional analysis through modification of sodium hot pool from one to three dimensions

2010-10-01

409

Memory of multiple aging stages above the freezing temperature in the Relaxor ferroelectric PLZT.  

Science.gov (United States)

The dynamic dielectric susceptibility and the elastic compliance of the relaxor ferroelectric lanthanum lead zirconate titanate (PLZT) 9/65/35 have been measured under different cooling and heating protocols in order to study aging and memory. The memory of multiple aging stages at different temperatures has been found (several dips in the susceptibility curves on heating), as in spin glass systems below the glass transition. Remarkably, in PLZT the memory of several aging stages is retained also above the freezing temperature deduced from the dynamic susceptibilities. The results are discussed in light of the existing models of aging and memory in spin and dipolar glasses. PMID:15447139

2004-08-24

410

Magnetic and electronic properties of Mn{sub 4}Si{sub 7}  

Energy Technology Data Exchange (ETDEWEB)

We present a systematic study of the magnetization, Hall effect and specific heat on single crystals of Mn{sub 4}Si{sub 7}. Curie-Weiss law is observed above 43 K. At low-temperature moments order in an anisotropic helical state and are aligned above 1 T. We observe an anomalous Hall effect in both {rho}{sub H} vs. B and in R{sub H} vs. T curves and a field dependence of the low T specific heat due to spin fluctuations. The magnetic moments (p{sub eff} and p{sub sat}) are the lowest reported for similar itinerant magnetic systems, this suggests that Mn{sub 4}Si{sub 7} is a good candidate to observe critical quantum fluctuations expected for a marginal Fermi liquid.

2004-05-01

411

Low energy ion scattering study of palladium films on silicon(111)-7 x 7 surfaces  

Energy Technology Data Exchange (ETDEWEB)

The initial growth process and surface structure of thin Pd(silicide) films on clean Si(111)-7x7 surfaces have been studied by low energy ion scattering (ISS) and LEED-Auger techniques. Considerable reaction between Pd and Si at room temperature is observed to extend up to 25 ML thickness of deposited Pd. Heat treatment of the room temperature film produced epitaxial silicide Pd/sub 2/Si(0001) films covered with the accumulated elementary Si layers of 1-2 ML thickness. Deposition of 1/3 ML Pd onto a heated substrate gives a Pd-embedded ordered surface of Si(111)-..sqrt..3x..sqrt..3R30/sup 0/, the feature being similar to the cases of Ag, Au/Si(111) systems.

1983-12-15

412

Low energy ion scattering study of palladium films on silicon(111)-7 x 7 surfaces  

International Nuclear Information System (INIS)

The initial growth process and surface structure of thin Pd(silicide) films on clean Si(111)-7x7 surfaces have been studied by low energy ion scattering (ISS) and LEED-Auger techniques. Considerable reaction between Pd and Si at room temperature is observed to extend up to 25 ML thickness of deposited Pd. Heat treatment of the room temperature film produced epitaxial silicide Pd_2Si(0001) films covered with the accumulated elementary Si layers of 1-2 ML thickness. Deposition of 1/3 ML Pd onto a heated substrate gives a Pd-embedded ordered surface of Si(111)-#sq root#3x#sq root#3R30"0, the feature being similar to the cases of Ag, Au/Si(111) systems. (orig.).

413

High-specific-output diesel engines  

Energy Technology Data Exchange (ETDEWEB)

The diesel engine is the most efficient device for converting chemical energy stored in liquid hydrocarbon fuels into useful work. Up to 50% of the energy in the fuel is converted into output shaft work. The modern diesel engine is twice as efficient as the early diesel engines and produces as much as sixty times as much power for a given cylinder size. These developments have, in recent years, been accompanied by a substantial reduction in the noxious elements in the exhaust gas so that engines are now, relatively speaking, ecologically clean. The developments have centred around exhaust gas turbocharging and improved fuel injection systems, but recent work on low-heat-rejection engines has resulted in significant advances in structural ceramics and in high-temperature lubricating oil, as well as an enhanced understanding of heat transfer in high-temperature combustion chambers. (author).

1991-01-01

414

Equipment for a central heating system with expansion tank, pressure control, water loss supply, de-aeration, recording and control; Apparaat t.b.v. C.V.-installatie met expansievat, drukregeling, waterverliessuppletie, ontluchting, registratie en controle  

Energy Technology Data Exchange (ETDEWEB)

The very low-pressure expansion tank of the title invention is connected to the water in the central heating installation via a connecting pipe with a pump and valves on one side, and on the other side the tank is connected via a connecting pipe with valve to the tap water mains, so that the supply of water can be regulated automatically. Within the expansion tank contact with the outside air is not possible because of an air/water separating floater. By means of recording and control (also remote) of the contents of the expansion tank, the installation pressure and the quantity of supplied water from the expansion tank and the tap water mains, failures and water damage are prevented. 4 figs.

1995-09-01

415

Energy from waste: current progress in Sweden  

Energy Technology Data Exchange (ETDEWEB)

Considerable effort worldwide has been put into trying to find the best way to utilise the large amount of energy that we put into our dustbins every day. One of the problems encountered is that the waste collection systems tend to gather together in one place between 400 and 1000 t of the stuff everyday and since it is possible to extract rather more than 2 MW from each tonne, that is a lot of energy for which to find a market. In continental European cities, especially Germany, and Sweden with most of the population living in apartment blocks, and with colder winters than the UK, district heating provides a suitable market. With its milder winters, more diverse housing and cheap gas the UK is not such a fertile ground for district heating. But since the passing of the Energy Act in 1984, there is a steady market in electricity generation with the advantage that the purchase tariffs are published so that income can be ...

1988-11-01

416

Effects of the alfven wave spectrum in heating experiments in TCA  

International Nuclear Information System (INIS)

Reduction of the metallic impurity concentration in the TCA plasma has enabled us to correlate the observed heating with the calculated position where the rf energy is deposited. In modelling the measured antenna loading due to the presence of Alfven resonance surfaces, and hence inferring the energy deposition profile, both ion cyclotron effects and the toroidal geometry must be considered. In particular, toroidicity couples energy to resonance surfaces that would not be excited in cylindrical geometry. The increase in electron density during a rf pulse changes the positions of these surfaces so that spectrum-related effects may be observed. The appearance of a new surface at the centre of the plasma is seen as a sharp discontinuity on many of the macroscopic parameters, accompanied by evidence of changes in the current density profile. These results, and the predictions of numerical codes, have imposed new constraints on the optimisation of our antenna ...

417

Development of standard solutions for the Minergie standard; Standardloesungen - Entwicklung von Standardloesungen fuer den Minergie-Standard  

Energy Technology Data Exchange (ETDEWEB)

This final report for the Swiss Federal Office of Energy (SFOE) examines a project that aimed to define standard solutions for use in buildings built to meet Minergie low energy consumption standards. These standard solutions are to provide a way of meeting Minergie standards in an easy way and thus further the use of the standard and also assure quality at the same time. The report describes how the solutions were developed on the basis of a selection of existing Minergie buildings. For various combinations of heating systems - wood, wood/solar, heat pumps (brine-water and air-water), gas/solar and oil/solar - the appropriate U-values for various building elements are listed. The resulting Minergie forms and guides are listed.

2003-07-01

418

Determination of two-phase natural circulation interfacial parameters by real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Experimental investigations have been conducted to determine two-phase natural circulation interfacial parameters by real-time neutron radiography. The natural circulation loop used in the present experiments consists of a vertical two-phase section, a gas liquid separator, and a gas injection/heating section. Experiments were performed in a neutron beam for visualization using realtime neutron radiography system. The natural circulation was initiated by injection of known gas flow rate in the heated section. Two-phase flow interfacial parameters including interfacial geometry and phase velocities etc. for bubbly flow and slug flow patterns observed in the experiments will be given in detail. The results indicate that while the natural circulation is largely as expected and that steady stable flows are possible, there are some local phenomena that introduce instabilities due to the interfacial phenomena between the liquid ...

2003-07-01

419

Determination of two-phase natural circulation interfacial parameters by real-time neutron radiography  

International Nuclear Information System (INIS)

Experimental investigations have been conducted to determine two-phase natural circulation interfacial parameters by real-time neutron radiography. The natural circulation loop used in the present experiments consists of a vertical two-phase section, a gas liquid separator, and a gas injection/heating section. Experiments were performed in a neutron beam for visualization using realtime neutron radiography system. The natural circulation was initiated by injection of known gas flow rate in the heated section. Two-phase flow interfacial parameters including interfacial geometry and phase velocities etc. for bubbly flow and slug flow patterns observed in the experiments will be given in detail. The results indicate that while the natural circulation is largely as expected and that steady stable flows are possible, there are some local phenomena that introduce instabilities due to the interfacial phenomena between the liquid ...

2003-10-05

420

Design and performance of a 100-kg/h, direct calcine-fed electric-melter system for nuclear-waste vitrification  

Energy Technology Data Exchange (ETDEWEB)

This report describes the physical characteristics of a ceramic-lined, joule-heated glass melter that is directly connected to the discharge of a spray calciner and is currently being used to study the vitrification of simulated nuclear-waste slurries. Melter performance characteristics and subsequent design improvements are described. The melter contains 0.24 m/sup 3/ of glass with a glass surface area of 0.76 m/sup 2/, and is heated by the flow of an alternating current (ranging from 600 to 1200 amps) between two Inconel-690 slab-type electrodes immersed in the glass at either end of the melter tank. The melter was maintained at operating temperature (900 to 1260/sup 0/C) for 15 months, and produced 62,000 kg of glass. The maximum sustained operating period was 122 h, during which glass was produced at the rate of 70 kg/h.

1980-11-01

421

Design and operation of an apparatus for calorimetric emittance measurements of pipe surfaces  

Energy Technology Data Exchange (ETDEWEB)

A technique for the measurement of the total hemispherical emittance of pipe surfaces is described, and design and operational details are given. The technique is conceptually simple. A long test pipe (e.g., 3.4 m) is mounted concentrically inside a Pyrex glass pipe. The system is evacuated, and the test pipe is heated by means of an electrical resistance heater. Heat transfer from the test pipe to the enclosure is almost solely radiative, allowing an average emittance for the test pipe and the Pyrex pipe and the electrical power input to the heater. By varying the electrical power level, one can measure the test pipe emittance as a function of temperature. By using a simple correction to account for the finite length of the test pipe, one can calculate the results using the simple expression for infinite, concentric cylinders. Results agree with measurements by reflectance techniques and have a nominal relative error of ...

1981-10-01

422

Combining satellite data and models to estimate cloud radiative effect at the surface and in the atmosphere  

British Library Electronic Table of Contents (United Kingdom)

Abstract Satellite measurements and numerical forecast model reanalysis data are used to compute an updated estimate of the cloud radiative effect on the global multi-annual mean radiative energy budget of the atmosphere and surface. The cloud radiative cooling effect through reflection of short wave radiation dominates over the long wave heating effect, resulting in a net cooling of the climate system of - 21 Wm-2. The short wave radiative effect of cloud is primarily manifest as a reduction in the solar radiation absorbed at the surface of - 53 Wm-2. Clouds impact long wave radiation by heating the moist tropical atmosphere (up to around 40 Wm-2 for global annual means) while enhancing the radiative cooling of the atmosphere over other regions, in particular higher latitudes and sub-trop...

2011-01-01

423

Anodic corrosion protection of sulphuric acid plants with regard to the recovery of heat  

Energy Technology Data Exchange (ETDEWEB)

Anodic protection makes it possible to keep materials which can be passivated in a 'passive' state or to bring them into this state, even in unfavourable conditions. With sulphuric acid concentrations of 93-99% this method permits the use of inexpensive, stainless austenitic steels, e.g. 1.4541 and 1.4591, at temperatures of up to 160/sup 0/C. The temperature range from 120/sup 0/C, in particular, is suitable for heat recovery. Anodic protection by the APR-system provides safe and low-cost protection for air coolers and bare tube coolers in sulphuric acid plants. The results of laboratory, pilot plant and commercial trials show that in this way a safe operation of sulphuric acid coolers is possible on a long-term basis.

1982-05-01

424

A simple dynamic model for solid transport in rotary dryers  

Energy Technology Data Exchange (ETDEWEB)

The solid particle movement in a rotary drum plays an important role in drying processes. The solid distribution in the drum affects the amount of contact surface between the solid and the gas. The retention time of solids influences the time particles can stay in contact with the gas in order to transfer heat and mass. Any heat and mass transfer model for a solid particle dryer must be able to predict solid flowrate and solid hold-up. There have been several reports in the literature regarding the modeling aspects of solid transport in dryers. If the model is developed for model-based control, it must be simple and yet represent dynamics of the system accurately. This paper addresses solid motion modeling and the effects of different variables involved in solid transport phenomena.

2000-05-01

425

Safe conditions for contacting nitric acid or nitrates with tri-n-butyl phosphate (TBP)  

Energy Technology Data Exchange (ETDEWEB)

In response to a request from DOE-SR, the current state of knowledge of the reactions between TBP and aqueous nitrate solutions is critically reviewed, and recommendations are made for the safe operation of SRS separations equipment in which this combination of chemicals may be present. The existing limits for evaporation are validated. Guidelines are presented for cases in which general limits do not apply. The rate of reaction between nitric acid and TBP appears to be controlled by the rate of TBP hydrolysis. The hydrolysis reaction produces dibutyl phosphate and n-butanol. The hydrolysis rate is a strong function of temperature, and becomes very fast at temperatures in the range 130{degrees} to 150{degrees}C. The resulting n-butanol is volatile at high temperatures, boiling at 117.5{degrees}C, but is also subject to exothermic oxidation by nitric acid or nitrates. If oxidation occurs before the n-butanol evaporates, the heat of oxidation may exceed local cooling ...

1994-01-01

426

Electric intake air heating for small and medium-sized diesel engines; Elektrische Ansaugluft-Vorwaermung bei kleineren und mittleren Dieselmotoren  

Energy Technology Data Exchange (ETDEWEB)

In addition to dependable starting - even at extreme sub-zero temperatures - the starting behaviour of modern commercial vehicle diesel engines is increasingly being evaluated on the basis of HC emissions in the starting and warm-up phases. To improve their performance in this respect, most small and medium-sized diesel engines (with a capacity of 3 to 12 litres) are therefore equipped with intake air heating systems. As an alternative to high-performance, fuel-burning flame start systems, the automotive industry supplier Beru has now developed a new type of self-regulating electric heating element which not only ensures dependable starting with short heating times but also allows drastic reductions in HC emissions. (orig.) [Deutsch] Das Startverhalten moderner Nutzfahrzeug-Dieselmotoren wird, ergaenzend zum Hauptmerkmal des sicheren Starts auch bei extremen Minustemperaturen, ...

1997-04-01

427

Engineering Development of Coal-Fired High-Performance Power Systems  

Energy Technology Data Exchange (ETDEWEB)

A High Performance Power System (HIPPS) is being developed. This system is a coal-fired, combined cycle plant with indirect heating of gas turbine air. Foster Wheeler Development Corporation and a team consisting of Foster Wheeler Energy Corporation, Bechtel Corporation, University of Tennessee Space Institute and Westinghouse Electric Corporation are developing this system. In Phase 1 of the project, a conceptual design of a commercial plant was developed. Technical and economic analyses indicated that the plant would meet the goals of the project which include a 47 percent efficiency (HHV) and a 10 percent lower cost of electricity than an equivalent size PC plant. The concept uses a pyrolysis process to convert coal into fuel gas and char. The char is fired in a High Temperature Advanced Furnace (HITAF). The HITAF is a pulverized fuel-fired boiler/air heater where steam is generated and gas turbine ...

2000-12-31

428

Analysis of cost-effective pipe insulation requirements  

Energy Technology Data Exchange (ETDEWEB)

The proposed ASHRAE/IES Standard 90.1-1989R contains updated requirements for pipe insulation thicknesses developed on the basis of technical and economic principles. These requirements were determined based on computer simulations of the annual energy loss through the insulation, first cost assumptions for the insulation, and economic assumptions of discount rate and energy escalation rate. In later work, the same tools were used to analyze the sensitivity of the cost-effective insulation level for piping insulation to variations in operating hours, ambient temperature, fluid temperature, and economic assumptions. These analyses were carried out using cost data for pipe insulation averaged across several sources. The results of the sensitivity study showed that system operating hours is a critical parameter in determining the cost-effective pipe insulation thicknesses. Although there is a lack of reliable sources of typical operating hour data for ...

1997-09-01

429

Unique approach to an old problem: New technology helps BC Hydro locate heat resistance  

Energy Technology Data Exchange (ETDEWEB)

BC Hydro`s approach to improve the performance of its underground transmission lines by employing new computer technology with fibre optic cables was described. Known as Distributed Temperature Sensing (DTS), the technology is expected to increase the capacity of the most heavily-loaded sections of its seven kilometer underground 230 kV transmission system in the Greater Vancouver area. Although it is also a concern in overhead wires, heating is particularly problematic in underground cable systems. DTS uses opto-electronic equipment to launch a laser light down conventional communications-grade fibre optic cables, installed in the same duct as the cables, or in a spare duct next to them. By using high speed measurements and computer processing, it is possible to determine the temperature all along the fibre with very high accuracy, and to locate any point along the length of the cable line to within two meters over ...

1997-06-01

430

Second law analysis of compressible flow through a diffuser subjected to constant heat flux at wall  

International Nuclear Information System (INIS)

Entropy generation is equivalent to destruction of available work (exergy). The useful energy is destroyed due to the intrinsic irreversibility associated within thermodynamic systems. Exergy analysis can be used as an effective basis for the development and improvement of systems design not only in the overall perspective but also in the individual component level. Second law analysis provides a useful tool to identify the irreversibility in any thermal system. This study presents the investigation of local and total entropy generation in compressible flow through a diffuser. Air is used as the fluid. Uniform heat flux boundary condition is applied at the wall. Two dimensional solution of velocity and temperature fields are obtained using the CFD code FLUENT. Distribution of entropy generation rate is investigated throughout the volume of the fluid as it flows through the diffuser. Regions of high ...

2010-12-01

431

Report on the Swedish National Energy Administration's program for energy efficiency 1998-2001; Redovisning av Energimyndighetens insatser foer energieffektivisering aaren 1998-2001  

Energy Technology Data Exchange (ETDEWEB)

Support for raising energy efficiency is reported for the following five areas during 1998-2001: 1. Fuel-based energy systems with the sub-areas: Sustainable production of biofuels, including ash recycling; Cogeneration; and Large scale heat production. 2. Transport with two sub-areas: Internal combustion engines; and Electric drive-lines. 3. Power production/Power technology with the sub-areas: Hydropower; Wind power; Power transmission and distribution; and Photovoltaic solar cells. 4. Industry with the sub-areas: Processes; and Support systems in industry. 5. Buildings with the sub-areas: Heating, cooling and climatic shields; and Components and support systems. In total, 1,800 M SEK (about 180 M USD) was contributed by the Energy Administration during this period. An overview of the projects is presented in this report.

2002-01-01

432

MTX diagnostic and timing system for free-electron laser heating experiments  

International Nuclear Information System (INIS)

In the microwave tokamak experiment (MTX) program, we are concentrating on experiments using intense, free-electron laser (FEL) generated microwave pulses. In initial FEL experiments, several diagnostic instruments were operated during injection of microwave pulses with peak powers to 0.2 GW at durations of 10 ns. Fixed and spatially scanning microwave detectors and receivers and a 48-element calorimeter on the inside wall of MTX diagnosed the GW-level FEL microwave pulses. With these diagnostics, linear-wave absorption and efficiencies of transmission through the quasi-optical transport system were studied. In addition, several radially resolved measurements of plasma density, temperature, and emission were made during FEL injection and were used in the analysis of microwave absorption data. A timing system, slaved to the FEL pulse arrival time, is capable of accuracy to a few nanoseconds in order to allow measurement of ...

433

Free and forced convective cooling of pipe-type electric cables. Volume 2: electrohycrodynamic pumping. Final report  

Energy Technology Data Exchange (ETDEWEB)

A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one, reported in Volume 1, dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of entrance and exit chambers ...

1981-05-01

434

Free and forced convective cooling of pipe-type electric cables. Volume 1: forced cooling of cables. Final report  

Energy Technology Data Exchange (ETDEWEB)

A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one reported in this volume dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of entrance and exit ...

1981-05-01

435

Development of a best estimate auditing code for CANDU thermal hydraulic safety analysis  

Energy Technology Data Exchange (ETDEWEB)

The main purpose of this study is to develop a thermal hydraulic auditing code for the CANDU reactor, modifying the model of existing PWR auditing tool , i.e. RELAP5/MOD3. This scope of project is a fourth step of the whole project, applying the RELAP5/MOD3/CANDU+ version for the real CANDU plant LOCA Analysis and D2O leakage incident. There are three main models under investigation, i.e. Moody critical flow model, flow regime model of horizontal CANDU bundle, and fuel element heatup model when the stratification occurs, especially when CANDU LOCA is tested. Also, for Wolsung unit 1 D2O leakage incident analysis, the plant behavior is predicted with the newly developed version for the first 1000 seconds after onset of the incident, with the main interest aiming for system pressure, level control system, and thermal hydraulic transient behavior of the secondary system. The model applied for this particular application ...

2001-03-01

436

Development and validation of steam generator models for thermal performance monitoring  

International Nuclear Information System (INIS)

The thermal performance monitoring and optimization system TEMPO is developed at the OECD Halden Reactor Project. The system supports staff of nuclear power plants in identification and correction of problems, which cause small decreases in plant efficiency but which may lead to significant economical losses. The system-wide physical model consists of mathematical description of individual components, such as the reactor, the pumps, the heat exchangers, or the turbines, etc. TEMPO code has recently been extended with new steam generator (SG) models. The present paper summarizes the thermal-hydraulic modelling aspects of the vertical and the horizontal SG. The heat balance equations and their solution are shown with the appropriate initial and boundary conditions. The method of the calculation of the pressure losses are also introduced. The vertical SG model is based on a U-tube ...

2003-04-20

437

Corrosion resistant coatings for silicon carbide heat exchanger tubes -- Volume 3. Final report  

Energy Technology Data Exchange (ETDEWEB)

The development of a silicon carbide (SiC) heat exchanger is a critical step in the development of the Externally-Fired Combined Cycle (EFCC) power system. SiC is the only material that provides the necessary combination of resistance to creep, thermal shock, and oxidation. While the SiC structure materials provide the thermomechanical and thermophysical properties needed for an efficient system, the mechanical properties of the SiC tubes are severely degraded through corrosion by the coal combustion products. To obtain the necessary service life of thousands of hours at temperature, a protective coating is needed that is stable with both the SiC tube and the coal combustion products, resists erosion from the particle laden gas stream, is thermal shock resistant, adheres to SiC during repeated thermal shocks (start-up, process upsets, shut-down), and allows the EFCC system to be cost competitive. This ...

1996-06-07

438

Conceptual study on advanced PWR system  

Energy Technology Data Exchange (ETDEWEB)

In this study, the adoptable essential technologies and reference design concept of the advanced reactor were developed and related basic experiments were performed. (1) Once-through Helical Steam Generator: a performance analysis computer code for heli-coiled steam generator was developed for thermal sizing of steam generator and determination of thermal-hydraulic parameters. (2) Self-pressurizing pressurizer : a performance analysis computer code for cold pressurizer was developed. (3) Control rod drive mechanism for fine control : type and function were surveyed. (4) CHF in passive PWR condition : development of the prediction model bundle CHF by introducing the correction factor from the data base. (5) Passive cooling concepts for concrete containment systems: development of the PCCS heat transfer coefficient. (6) Steam injector concepts: analysis and experiment were conducted. (7) Fluidic diode concepts : analysis and experiment were ...

1997-07-01

439

Commercial acceptability of solid polymer fuel cell systems in the role of combined heat and power packages  

Energy Technology Data Exchange (ETDEWEB)

This report aims to address the potential for solid polymer fuel cell (SPFC) systems to be successfully exploited in the combined heat and power (CHP) market. A number of market studies have been undertaken to look at the size and future potential for this CHP market as well as such issues as market forces and geographical locations. This study focuses on a different aspect, that of the technical and commercial requirement together with the development needs. In order to understand how an SPFC system will have to perform, it is first necessary to examine the criteria used to judge the commercial merits of a particular CHP scheme. Issues that must be addressed include: the investment criteria - time to pay back the investment or rate of return on the investment; the influence of external factors such as electricity cost tariffs, fuel price and regulatory requirements; the cost and performance of existing technology; and the ...

1998-09-01

440

CFD code fluent turbulence models application. Ansaldo's prototype modeling  

International Nuclear Information System (INIS)

Among others, one of the main activities in the Nuclear Engineering and Fluid Mechanics Department of the Engineering School in Bilbao, is the study of liquid metals behavior. And for this purpose the CFD code FLUENT is being used. Currently, the code is being applied to the use of Lead-Bismuth eutectic (LBE) as the coolant of an accelerator driven system (ADS) and also as the target for a neutron source. In this paper, ANSALDO's Energy Amplifier Demonstration Facility is simulated, paying attention only on the coolant. As it will be later explained, natural convection is a very important issue, because the philosophy for safety systems in nuclear devices tends to consider passive technologies. The purpose is to avoid electrical machines like pumps, so the core should remain coolable, even if there is a blackout. To get this natural circulation, heat transfer plays a main role, and as turbulence enhances the ...

2001-12-04

441

Heat transfer problems in high temperature heat exchangers  

International Nuclear Information System (INIS)

This paper deals with construction types of high temperature heat exchangers, their circulation loops and temperature differences. Most attention is given to gas dynamics, convective heat transfer, convection and radiant heat transfer interaction in high temperature heat exchangers. The ways of heat transfer augmentation and efficient heat exchanger construction are discussed.

1986-01-01

443

Venus surface power and cooling systems  

British Library Electronic Table of Contents (United Kingdom)

A mission to the surface of Venus would have high scientific value, but most electronic devices and sensors cannot operate at the 450degreeC ambient surface temperature of Venus. Power and cooling systems were analyzed for Venus surface operation. A radioisotope power and cooling system was designed to provide electrical power for a probe operating on the surface of Venus. For a mission duration of substantial length, the use of thermal mass to maintain an operable temperature range is likely impractical, and active refrigeration may be required to keep components at a temperature below ambient. Due to the high thermal convection of the high-density atmosphere, the heat rejection temperature was assumed to be at a 500degreeC radiator temperature, 50degreeC above ambient. The radioisotope S...

2007-01-01

444

Thermal-fluid flow analysis and demonstration test of a spent fuel storage system  

Energy Technology Data Exchange (ETDEWEB)

Thermal-fluid flow analysis and demonstration test were performed for a spent fuel storage system. The commercial computational fluid dynamics (CFD) code, FLUENT was used for the numerical analysis. Effective thermal conductivities of a spent fuel assembly and a fuel basket were derived to optimize a thermal analysis model. Also, a porous model, which can simplify a complex configuration of a fuel assembly, was used in the thermal analysis. Demonstration test were performed to verify the thermal analysis method and procedure using a half scaled-down model and an electrically heated dummy fuel. The numerical analysis results were compared with the experimental data. Thermal analyses of the storage system were carried out for normal and off-normal conditions by using the verified analysis method.

2009-03-15

445

Negative-ion based NBI system for JT-60U  

Energy Technology Data Exchange (ETDEWEB)

A 500 keV negative-ion based NBI system is under construction for NB current drive and plasma core heating in high density plasma in JT-60U. Part of the beamline and the high voltage power supply required for a verification test of an ion source was completed in March 1995. After having done a high potential test of the power supply, the negative-ion generation and acceleration tests started in June 1995 aiming at deuterium beams of 500 keV, 22A. In initial experiment, deuterium negative-ion beams of 410 keV, 6.1A (2.5 MW) for 0.2 sec, so far, have been achieved. This is the world highest D{sup {minus}} current and negative ion beam power. The construction of the total system will be completed by the beginning of 1996, and the beam injection will start in March 1996.

1995-12-31

446

Natural convection cooling of liquid metal systems  

International Nuclear Information System (INIS)

The recognition that natural convection offers the prospect of an important inherent safety feature for liquid metal cooled reactor systems has provided the impetus for a world-wide research effort over the past decade. Whilst this research has been based on experiment, both plant experiments and out-of-pile experiments, the enormous advances in the development of computing power in recent years have enabled complementary programmes of mathematical modelling through numerical simulation of the transport equations in three spatial dimensions. These not only offer considerable promise for the designer in projecting the behaviour from experiments and prototype plant to full scale plant, they have also proved to be of considerable value in helping us to interpret and understand the results of the experiments themselves. This paper attempts to review the progress made with the emphasis on decay heat removal by natural convection in the pool-type ...

447

Mathematical modeling of the behavior of geothermal systems under exploitation  

Energy Technology Data Exchange (ETDEWEB)

Analytical and numerical methods have been used in this investigation to model the behavior of geothermal systems under exploitation. The work is divided into three parts: (1) development of a numerical code, (2) theoretical studies of geothermal systems, and (3) field applications. A new single-phase three-dimensional simulator, capable of solving heat and mass flow problems in a saturated, heterogeneous porous or fractured medium has been developed. The simulator uses the integrated finite difference method for formulating the governing equations and an efficient sparse solver for the solution of the linearized equations. In the theoretical studies, various reservoir engineering problems have been examined. These include (a) well-test analysis, (b) exploitation strategies, (c) injection into fractured rocks, and (d) fault-charged geothermal reservoirs.

1982-01-01

448

Malaspina University-College's green building strategy  

Energy Technology Data Exchange (ETDEWEB)

This brochure describes the strategy employed by the administration of Malaspina University--College in Nanaimo, British Columbia, to implement energy-efficient plans and integrating systems and plans that would allow the institution to consume less energy, fewer resources and improve the health and well-being of its students and staff. An assessment study to identify the most problematic areas, and to develop a prioritizing strategy for their replacement was the first step, followed by rigorous adherence to a 10- year cyclical replacement schedule. The program includes replacement of rooftop ventilation units, installation of high-performance glazing units to replace single-glazed windows, implementation of an Energy Management System to monitor heating, ventilating and air conditioning systems, and a Power Smart New Building Design and Building Improvements Program. The combined cost avoidance ...

2000-01-01

449

Helium-cooling in fusion power plants  

Energy Technology Data Exchange (ETDEWEB)

This paper reviews different helium-cooled first wall and blanket designs; and compares the selection of structural materials. The authors found that the solid breeder, SiC-composite material option generates the lowest amount of induced radioactivity and afterheat and has the highest temperature capability. When combined with the direct cycle gas turbine system, it has the potential to be the most economical fusion system and can compete with advanced fission reactors. When compared to martensitic steel and V-alloy, SiC-composite is the least developed of these three structural materials, a focused development effort will be needed. Fundamental research has begun in addressing the issues of optimized composite materials, irradiation effects, leak tightness and low activation braze materials. Development of helium-cooled high heat flux components and further development of the direct cycle gas turbine ...

1994-11-01

450

Five years operating experience at the Fast Flux Test Facility  

Energy Technology Data Exchange (ETDEWEB)

The Fast Flux Test Facility (FFTF) is a 400 Mw(t), loop-type, sodium-cooled, fast neutron reactor. It is operated by the Westinghouse Hanford Company for the United States Department of Energy at Richland, Washington. The FFTF is a multipurpose test reactor used to irradiate fuels and materials for programs such as Liquid Metal Reactor (LMR) research, fusion research, space power systems, isotope production and international research. FFTF is also used for testing concepts to be used in Advanced Reactors which will be designed to maximize passive safety features and not require complex shutdown systems to assure safe shutdown and heat removal. The FFTF also provides experience in the operation and maintenance of a reactor having prototypic components and systems typical of large LMR (LMFBR) power plants. The 5 year operational performance of the FFTF reactor is discussed in this report. 6 refs., 10 ...

1987-04-01

451

Five years operating experience at the Fast Flux Test Facility  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a 400 Mw(t), loop-type, sodium-cooled, fast neutron reactor. It is operated by the Westinghouse Hanford Company for the United States Department of Energy at Richland, Washington. The FFTF is a multipurpose test reactor used to irradiate fuels and materials for programs such as Liquid Metal Reactor (LMR) research, fusion research, space power systems, isotope production and international research. FFTF is also used for testing concepts to be used in Advanced Reactors which will be designed to maximize passive safety features and not require complex shutdown systems to assure safe shutdown and heat removal. The FFTF also provides experience in the operation and maintenance of a reactor having prototypic components and systems typical of large LMR (LMFBR) power plants. The 5 year operational performance of the FFTF reactor is discussed in this report. 6 refs., 10 ...

1987-09-13

452

Dietary plant materials reduce acrylamide formation in cookie and starch-based model systems  

British Library Electronic Table of Contents (United Kingdom)

Abstract BACKGROUND: Dietary plant materials have attracted much attention because of their health benefits to humans. Acrylamide is found in various heated carbohydrate-rich foods. Our previous results showed that crude aqueous extracts from diverse dietary plants and some phenolic compounds could mitigate acrylamide formation in an asparagine-glucose model system. Based on our previous study, several plant materials were selected to further investigate their inhibitory effects on acrylamide formation in cookies and starch-based model systems. RESULTS: Addition of raw powders from selected dietary plants and their crude aqueous extracts could considerably reduce acrylamide formation in both cookie and potato starch-based models. Aqueous extracts of clove at 4% caused the largest reduction...

2011-01-01

453

Capturing the Daylight Dividend  

Energy Technology Data Exchange (ETDEWEB)

Capturing the Daylight Dividend conducted activities to build market demand for daylight as a means of improving indoor environmental quality, overcoming technological barriers to effective daylighting, and informing and assisting state and regional market transformation and resource acquisition program implementation efforts. The program clarified the benefits of daylight by examining whole building systems energy interactions between windows, lighting, heating, and air conditioning in daylit buildings, and daylighting's effect on the human circadian system and productivity. The project undertook work to advance photosensors, dimming systems, and ballasts, and provided technical training in specifying and operating daylighting controls in buildings. Future daylighting work is recommended in metric development, technology development, testing, training, education, and outreach.

2006-04-30

454

Thermally conductive cementitious grouts for geothermal heat pumps. Progress report FY 1998  

Energy Technology Data Exchange (ETDEWEB)

Research commenced in FY 97 to determine the suitability of superplasticized cement-sand grouts for backfilling vertical boreholes used with geothermal heat pump (GHP) systems. The overall objectives were to develop, evaluate and demonstrate cementitious grouts that could reduce the required bore length and improve the performance of GHPs. This report summarizes the accomplishments in FY 98. The developed thermally conductive grout consists of cement, water, a particular grade of silica sand, superplasticizer and a small amount of bentonite. While the primary function of the grout is to facilitate heat transfer between the U-loop and surrounding formation, it is also essential that the grout act as an effective borehole sealant. Two types of permeability (hydraulic conductivity) tests was conducted to evaluate the sealing performance of the cement-sand grout. Additional properties of the proposed grout that were ...

1998-11-01

455

The 1992 Pacific Northwest Residential Energy Survey : Phase 1 (PNWRES92-I) : Book 12 : Non-Respondent Survey.  

Energy Technology Data Exchange (ETDEWEB)

This book constitutes a portion of the primary documentation for the 1992 Pacific Northwest Residential Energy Survey, Phase I. The complete 33-volume set of primary documentation provides information needed by energy analysts and interpreters with respect to planning, execution, data collection, and data management of the PNWRES92-I process. Thirty of these volumes are devoted to different ``views`` of the data themselves, with each view having a special purpose or interest as its focus. Analyses and interpretations of these data will be the subjects of forthcoming publications. Conducted during the late summer and fall months of 1992, PNWRES92-I had the over-arching goal of satisfying basic requirements for a variety of information about the stock of residential units in Bonneville`s service region. Surveys with a similar goal were conducted in 1979 and 1983. This volume contains a follow-up study of non-respondents to the original survey. The information is cross tabulated. ...

1993-08-01

456

Studies of initial stage in coal liquefaction. 4. Radical formation and structural change with thermal decomposition of coal; Ekika hanno no shoki katei ni kansuru kenkyu. 4. Netsubunkai ni tomonau radical seisei kyodo to kozo henka  

Energy Technology Data Exchange (ETDEWEB)

In relation to coal liquefaction reaction, the effect of the coexistence of transferable hydrogen (TH) from process solvent on reduction of radical concentration and the effect of pre-heat treatment on average structure of coals were studied. In experiment, change in radical concentration with temperature rise was measured using the system composed of Yallourn coal and process solvent. The results are as follows. Process solvent with a wide boiling point range of 180-420{degree}C is effective in suppressing an increase in radical concentration even at higher temperature. The effect of hydrogen-donating solvent increases with TH. It was also suggested that high-boiling point constituents in solvent stabilize radicals even over 400{degree}C by vapor phase hydrogenation. The experimental results of pre-heat treatment are as follows. Although the conversion improvement effect of TH is equivalent to that of the model solvent, TH ...

1996-10-28

457

Passive heat transfer augmentation in a cylindrical annulus utilizing multiple perturbations on the inner and outer cylinders  

Energy Technology Data Exchange (ETDEWEB)

The study of natural convection flow and heat transfer within a cylindrical annulus has received considerable attention because of its numerous applications, such as in nuclear reactor design, electronic component cooling, thermal storage systems, energy conservation, energy storage, and energy transmission. Here, the effects of multiple geometric perturbations on the inner and outer cylinders of an annulus with impermeable end walls are investigated in this work. A three-dimensional study was done using a numerical scheme based on a Galerkin method of finite element formulation. The nature of the buoyancy-induced flow field has been analyzed in detail. The flow fields for the cases considered were found to be qualitatively similar, and the introduction of each additional perturbation altered the flow field in a regular and recurring manner. The introduction of each perturbation on the outer cylinder causes clockwise and counterclock-wise ...

1999-05-14

458

Passive heat transfer augmentation in a cylindrical annulus utilizing multiple perturbations on the inner and outer cylinders  

International Nuclear Information System (INIS)

The study of natural convection flow and heat transfer within a cylindrical annulus has received considerable attention because of its numerous applications, such as in nuclear reactor design, electronic component cooling, thermal storage systems, energy conservation, energy storage, and energy transmission. Here, the effects of multiple geometric perturbations on the inner and outer cylinders of an annulus with impermeable end walls are investigated in this work. A three-dimensional study was done using a numerical scheme based on a Galerkin method of finite element formulation. The nature of the buoyancy-induced flow field has been analyzed in detail. The flow fields for the cases considered were found to be qualitatively similar, and the introduction of each additional perturbation altered the flow field in a regular and recurring manner. The introduction of each perturbation on the outer cylinder causes clockwise and counterclock-wise ...

1999-05-14

459

Nant-De-Chatillon: electric power generation by ORC (organic Rankine cycle) using waste heat from the Chatillon biogas plant; Nant-de-Chatillon: Production d'electricite par ORC a partir des rejets de chaleur du site de methanisation de Chatillon. Resume  

Energy Technology Data Exchange (ETDEWEB)

This report prepared for the Swiss Federal Office of Energy (SFOE) describes the practical realisation and testing of a heat recovery system based on a one-stage organic Rankine cycle with R134a as the working fluid. The waste heat has a temperature of 95 {sup o}C and originates from a gas engine that powers a small co-generation plant fuelled with biogas produced on-site. Two similar cycles have been built, ORC1 with one and ORC2 with two turbines. Only ORC1 has been tested so far. The maximum efficiency measured in these tests was 6.64% (theoretical Carnot-efficiency: 17 %) and the electric power output was 5.0 kW. The problems encountered during commissioning are described and recommendations for further improvements are given.

2005-07-01

460

Microwave radiation effects on the thermally driven oxidase of erythrocytes  

Energy Technology Data Exchange (ETDEWEB)

Sheep red blood cells (SRBCs) were labelled with a concanavalin A-luminol-bovine serum albumin conjugate specific for the transmembrane anion transport protein (Band 3) and exposed to 2450-MHz continuous-wave microwave radiation at an average specific absorption rate of 91W/kg for 10 min. The temperature was held constant at 25, 37, 40, 42, or 45C with an airflow heat-exchange system. Following exposure to microwave or air heating, the decrease in residual base-activated chemiluminescence (CL) of the SRBCs was measured as an indication of infield oxidase activity. Air heating resulted in a significant decrease in residual CL at temperatures above 37C (74% decrease at 45C). Microwave radiation inhibited the decline in residual CL above 37C. At 45C the inhibition was 40%. The results suggest microwave radiation either reversibly altered the thermodynamics of oxygen binding to haemoglobin or failed to ...

1986-01-01

461

Leading research on supermetal. Part 1. Large-scale materials (iron system); Super metal no sendo kenkyu. 1. Ogata sozai (tetsukei)  

Energy Technology Data Exchange (ETDEWEB)

Supermetal with critical characteristics is under advanced investigation for further improvement of metal materials. Although iron is most frequently used as structural material among various metals, it should be used more carefully and effectively because of resource limitation and global environmental problem. It is essential to draw various excellent properties much more from iron and to improve recyclability. In particular, the best way to meet these requirements is achievement of more fine structure and higher purity. Since the lowest crystalline grain size is now limited to nearly 10{mu}m, metallic structure composed of grains below 1{mu}m is expected by mesoscopic control. Various methods have been studied to achieve ultra-fine crystalline structure, and study of precise heat treatment control and ultra-strength metallurgy is required. Heat treatment in magnetic field and layered structure by mechanical alloying are also promising. ...

1996-03-01

462

Historical development of alloy 800  

International Nuclear Information System (INIS)

Alloy 800 was developed in 1949 by The International Nickel Company, Inc. The basic composition, nominally 32wt.%Ni, 20.5wt.%Cr and 46wt.%Fe, was designed to provide a stable, fully austenitic structure and to impart high strength combined with resistance to oxidation, carburization and corrosion in a wide variety of aggressive industrial environments at elevated temperatures. In the short span of twenty-five years, alloy 800 has earned a unique position in the family of heat- and corrosion-resistant materials. Established uses include a wide range of applications in the industrial heating field, in the petro-chemical industry, in domestic appliances and in food processing equipment. The good performance of alloy 800 in these applications has led to its use as boiler tube material both in fossil-fired plants and in HTGR and PWR nuclear power systems. Recently, it was specified for a PHW CANDU reactor and it is now being ...

463

Heat capacity measurements of atoms and molecules adsorbed on evaporated metal films  

Energy Technology Data Exchange (ETDEWEB)

Investigations of the properties of absorbed monolayers have received great experimental and theoretical attention recently, both because of the importance of surface processes in practical applications such as catalysis, and the importance of such systems to the understanding of the fundamentals of thermodynamics in two dimensions. We have adapted the composite bolometer technology to the construction of microcalorimeters. For these calorimeters, the adsorption substrate is an evaporated film deposited on one surface of an optically polished sapphire wafer. This approach has allowed us to make the first measurements of the heat capacity of submonolayer films of /sup 4/He adsorbed on metallic films. In contrast to measurements of /sup 4/He adsorbed on all other insulating substrates, we have shown that /sup 4/He on silver films occupies a two-dimensional gas phase over a broad range of coverages and temperatures. Our apparatus has been used to ...

1989-05-01

464

FY1999 Meeting of The Society of Heating, Air-Conditioning and Sanitary Engineering of Japan. Thermal simulation I; 1999 nendo gakujutsu koenkai gaiyo. Onnetsu simulation 1  

Energy Technology Data Exchange (ETDEWEB)

E-35 reported the specific air flow analysis program using a CFSV model (including a human body model) to develop a high-accuracy evaluation simulator for heterogeneous thermal environment based on human thermal physiological conditions. E-36 reported development of the radiation heat transfer analysis module by using a numerical integral method to calculate shape factors. Radiation heat transfer characteristics every body part were clarified quantitatively by this module. E-37 reported the results on continuous measurement of physiological conditions and thermal environment factors every monitor under controlled indoor thermal environment, to collect measurement data necessary for improving the accuracy of a prediction program for human body temperatures. E-38 reported the study result on physiological reaction and subjective evaluation through an examinee experiment in a blood controlled region, to collect basic data for the above ...

1999-12-05

465

Effects of transverse magnetic field, Prandtl number and Reynolds number on non-Darcy mixed convective flow of an incompressible viscous fluid past a porous vertical flat plate in a saturated porous medium  

Energy Technology Data Exchange (ETDEWEB)

The effect of transverse magnetic field parameter (Hartmann number, Ha) Reynolds number (Re) and Prandtl number (Pr) on the mixed convection flow past a semi-infinite vertical porous plate in a non-Darcian porous medium with variable viscosity and porosity, viscous dissipation and fluid-solid thermal conductivity ratio in the presence of plate transpiration (lateral mass flux) is investigated theoretically and numerically using Keller`s implicit finite difference scheme. It is shown that the Harmann number acts as a retarding force and increases the momentum boundary layer thickness, analogous to the flow against a positive pressure gradient, simultaneously decreasing local skin friction (shear stress). The heat transfer rate is however enhanced by the magnetic field (for positive values of the Eckert number) since the fluid is heated and temperature gradients become reduced between the fluid and the plate, with important potential applications ...

1997-01-01

466

Control of adsorption by microwave irradiation; Maikuroha nado wo mochiita gas no kyuchaku datsuri seigyo  

Energy Technology Data Exchange (ETDEWEB)

Introduced herein is microwave irradiation for the adsorption and desorption of environmental pollutants. Microwaves may be used in two ways, other than through elevation of temperature of a system as a whole with the adsorbent such as activated carbon serving as the heating medium. The first is the application by which desorption is caused to take place of specified molecules. For example, zeolite that has adsorbed water is regenerated when it is irradiated with microwaves in a stream of cooling gas. This is because only the moisture is heated since zeolite is a non-carbon adsorbent that absorbs microwaves but a little. Another case is reported in which microwaves are utilized to desorb H2S, H2O, CO, etc., from molecular sieves. In the second application, coexisting materials different in absorptivity are exposed to irradiation. The adsorption of microwave-absorbent materials is inhibited while that of the others is ...

1997-01-25

467

Chemical process equipment for Hitachi. ; Featured equipment  

Energy Technology Data Exchange (ETDEWEB)

The present article describes the specialities in various chemical process equipment fabricated by Hitachi. It introduces the thin-film evaporator which heats, vaporizes and concentrates high viscosity fluid and slurry under thin-film conditions, the centrifugal extractor which uses a high speed rotating rotor to separate two kinds of immiscible liquids effectively in counter current contact conditions under a gravitational force ranging from 2,000G to 4,500G, the process gas boiler and heat pipe equipment which recovers exhausted heat effectively from various plants, the furnace and quench systems which are applied to olefin plants, EDC cracking and steam reforming, and the equipment which has been supplied to chemical plants operated under severe conditions, such as high temperature, high pressure and corrosive atmosphere. It was demonstrated that these technologies and know-hows accumulated from ...

1993-01-01

468

Interim cryo-cooler/detector report  

Energy Technology Data Exchange (ETDEWEB)

This report describes development of an electronic system designed to reduce vibration generated by a cryocooler. The diminished vibration makes it practical to use the active cooler to extract heat from a portable gamma ray detector instrument. The system was developed for a Sunpower cryocooler with an integrated counterbalance mass. The overall momentum cancellation approach is also applicable to other similar cryocoolers. The cancellation system is an assembly of several components tailored to accomplish the required vibration reduction with minimum power consumption and volume. It is designed to be powered by a 18--32 Volt battery. Up to ten harmonics of the 58.65 Hz drive frequency are controlled. In addition to the vibration cancellation, the electronic system produces the drive signal for the cryocooler and regulates the cooler temperature. The system ...

1995-04-19

469

Impact of low-rank coal properties on advanced power systems  

Energy Technology Data Exchange (ETDEWEB)

Advanced coal-fired combined-cycle power systems under development and demonstration have the potential to increase generating efficiency to approach 50%, reduce the cost of electricity by up to 20%, and meet stringent standards on emissions of SO{sub x}, NO{sub x}, fine particulates, and air toxic metals. Integrated gasification combined cycle, pressurized fluidized-bed combustion, and externally fired combined cycle systems rely on different high-temperature combinations of heat exchange, gas filtration, and sulfur capture to meet these requirements. The success of these systems when operated on low-rank coals depends importantly on the behavior of the ash. This paper focuses on the behavior of ash in an intermediate-scale transport gasifier coupled with a hot-gas cleanup system. The work reported is part of the overall program on hot-gas cleanup and the transport reactor ...

1996-12-31

470

Fatty acid/poly(methyl methacrylate) (PMMA) blends as form-stable phase change materials for latent heat thermal energy storage  

Energy Technology Data Exchange (ETDEWEB)

Fatty acids such as stearic acid (SA), palmitic acid (PA), myristic acid (MA), and lauric acid (LA) are promising phase change materials (PCMs) for latent heat thermal energy storage (LHTES) applications, but high cost is the most drawback which limits the utility area of them in thermal energy storage. The use of fatty acids as form-stable PCM will increase their feasibilities in practical LHTES applications due to reduced cost of the energy storage system. In this regard, a series of fatty acid/poly(methyl methacrylate) (PMMA) blends, SA/PMMA, PA/PMMA, MA/PMMA, and LA/PMMA were prepared as new kinds of form-stable PCMs by encapsulation of fatty acids into PMMA which acts as supporting material. The blends were prepared at different mass fractions of fatty acids (50, 60, 70, 80, and 90% w/w) to reach maximum encapsulation ratio. All blends were subjected to leakage test by heating the blends over the melting temperature of ...

2008-02-15

471

Enhancement of Heat and Mass Transfer in Mechanically Contstrained Ultra Thin Films  

Energy Technology Data Exchange (ETDEWEB)

Oregon State University (OSU) and the Pacific Northwest National Laboratory (PNNL) were funded by the U.S. Department of Energy to conduct research focused on resolving the key technical issues that limited the deployment of efficient and extremely compact microtechnology based heat actuated absorption heat pumps and gas absorbers. Success in demonstrating these technologies will reduce the main barriers to the deployment of a technology that can significantly reduce energy consumption in the building, automotive and industrial sectors while providing a technology that can improve our ability to sequester CO{sub 2}. The proposed research cost $939,477. $539,477 of the proposed amount funded research conducted at OSU while the balance ($400,000) was used at PNNL. The project lasted 42 months and started in April 2001. Recent developments at the Pacific Northwest National Laboratory and Oregon State University suggest that the performance of ...

2005-01-01

472

A low-temperature calorimetric study of synthetic (forsterite+fayalite) {(Mg2SiO4+Fe2SiO4)} solid solutions: An analysis of vibrational, magnetic, and electronic contributions to the molar heat capacity and entropy of mixing  

International Nuclear Information System (INIS)

The molar heat capacities (Cp,m) of a series of synthetic forsterite (Fo)-fayalite (Fa), (Mg2SiO4+Fe2SiO4), olivines have been measured between 5K and 300K on milligram-sized samples with the Physical Properties Measurement System (Quantum Design(R)). Sharp, ?-type heat capacity anomalies are observed in the Fe-rich compositions fayalite, Fo10Fa90, Fo20Fa80, Fo30Fa70, and Fo40Fa60. The corresponding Neel temperatures TN decrease linearly from 64.5K in fayalite to 32.8K in Fo40Fa60 following the relationship TN=79.02.xFa-14.07. Fo50Fa50 and Mg-richer olivines show weak broad features in the heat capacity data around 15K to 20K that decrease in magnitude with increasing forsterite content. In order to derive and separate molar electronic, magnetic and vibrational heat capacity contributions, Cel,m, Cmag,m, and Cvib,m from the experimental heat capacities (Ctot,m), ...

2007-06-01

473

Screening Criteria for Loss of Room Cooling Failure  

Energy Technology Data Exchange (ETDEWEB)

In this report, we estimated the temperature of the pump rooms and reviewed the operability of the components under the loss of the HVAC (Heating, Ventilation, and Air Condition) system. The issues relevant to the HVAC system in the PSA (Probabilistic Safety Assessment) FT (Fault Tree) model are as follows: (1) Does the loss of the HVAC system bring about a function failure of other components? (2) Can the operator take action to reduce the temperature of the room in case of a HVAC function failure? At present, we do not know whether a component will lose its function or not under the loss of the HVAC. ASME Standard describes that a recovery action can be credited if the related recovery action is included in the procedure or there are similar recovery experiences in the plant. However, there is no description about the recovery action of the HVAC in the EOP (Emergency Operation Procedure) of the UCN3, ...

2007-01-15

474

Energy analysis of a solar pre-water heating system; Analise energetica de um sistema de pre-aquecimento solar de agua  

Energy Technology Data Exchange (ETDEWEB)

Several technological alternatives have been studied taking into consideration that one of the biggest problems of the electric power companies is to provide electric power during the peak consumption periods, which largest contribution to the increase of the demand comes from the residential sector, especially by the use of electric showers. One of the most promising alternatives is the pre-water heating system for reduced power showers, developed by Universidade de Campinas and Companhia Paulista de Forca e Luz. The goal of this system is basically to reduce demand during the peak periods, in order to avoid heavy investments by the electric power companies in generation, transmission and distribution of electric power directed to low acquisitive power customers, a sector in which the electric power price is not enough to recover such investments. The objective of this paper is to evaluate the total energy required in the ...

1996-12-31

475

Manitoba Hydro's earth power program and Manitoba market update  

International Nuclear Information System (INIS)

An outline of Manitoba Hydro's Earth Power program was presented. Details of the heat pump market in Manitoba were provided, including details of residential and commercial sales. Total residential heat pump sales amounted to 577 units in 2004, equivalent to over $11.2 million in sales. Commercial installations amounted to approximately $12.7 million. An outline of industry players was presented. The goals of Manitoba Hydro were outlined in relation to geothermal energy and the Power Smart program. Their objectives included increasing awareness of geothermal energy, making heat pumps more accessible, and improving industry infrastructure. Other objectives included educating the public about life-cycle cost implications, residential loans and commercial incentives. To date, the residential power loan has provided financing to over 300 Manitoba home owners for installations, with electrical savings of over 1.34 Gwh and ...

2005-02-24

476

High-pressure gas quenching in cold chambers for increased cooling capacity  

Energy Technology Data Exchange (ETDEWEB)

Gas quenching for the hardening of steel parts is a lower-pollution alternative to quenching in quenchants such as oil or salt. As the surfaces of the cooled parts remain clean after gas quenching, there is no need to wash them after heat treatment, which reduces the consumption of oils and detergents. The fire risk and ventilation requirements of oil quenching are eliminated. In addition, some trials have shown that gas quenching has a positive effect on distortion, representing a saving in finishing work and thus a reduction in costs. Today, gas quenching is used almost solely in vacuum furnaces. Quenching is normally performed in the same chamber as heating, which means that besides quenching the batch, the quenching system must also remove heat from the heating elements and insulation of the furnace. Previous trials performed by IVF have shown that gas quenching with helium of ...

1996-12-31

477

Experimental and theoretical studies on humidification-dehumidification-desalination  

Energy Technology Data Exchange (ETDEWEB)

The shortage of fresh water is increasing at alarming levels, even in temperate zones. Desalination of brackish and seawater is being considered as a solution to growing water demands. Seawater desalination can be accomplished through reverse osmosis, vapor compression, vapor absorption and thermally driven systems. The most suitable process for large-scale desalination plants is successive brine evaporation-condensation with intermediate heat recovery. However, higher process efficiency could be achieved. The use of low temperature heat sources in seawater desalination requires an efficient method of evaporation and condensation at relatively low vapor pressures. This could be achieved in a humidification-dehumidification process using circulated air to enhance evaporation of water. Simulation models, however, neglect either the heat of evaporation or the changes in air and water properties within ...

2006-07-01

478

Electron cyclotron heating  

International Nuclear Information System (INIS)

Electron cyclotron resonance heating (ECH) in BPX is planned as a possible upgrade to supplement the baseline ion cyclotron resonance frequency (ICRF) system. Eventual implementation primarily depends on the development of the required source technology. ECH offers important technical advantages over ICRF: High radio-frequency (FR) power density can be transmitted through ports (P/A >#approx# 100 MW/M"2), and the antenna need not be in contact with the plasma for efficient coupling. In particular, low-field side, linearly polarized (O-mode) power injection will suffice. By controlling the N spectrum, or by steering the antenna, the power deposition profile can be controlled during ramping of the magnetic field even with a fixed frequency source. Because of the possibility of localized power deposition, ECH is a natural candidate for controlling magnetrohydrodynamic (MHD) activity. Sawtooth oscillations may be prevented by ...

479

Engineering and manufacture of oblong-shaped metallic melters for enhancing vitrification throughputs  

International Nuclear Information System (INIS)

Most countries have taken the vitrification route for managing High Level Waste (HLW). Depending on composition of site-specific HLW, suitable glass forming oxides are added to it in a melting furnace designed for converting the mixture to a matrix of borosilicate glass. After thorough homogenization, the product is poured into stainless steel canisters as an inert solidified form. Canisters are seal welded and 2-3 such containers are then packed and sealed in another bigger container for providing an additional engineered barrier. This product form is considered safe for long-term storage. The concurrent vitrification technologies employ either induction-heated metallic melters or joule-heated direct resistance-heated ceramic melters. In India, both technologies have been adopted. While older facilities in Trombay and Tarapur employ metallic melters, a retrofitted facility at Tarapur and the new plant at Kalpakkam are ...

480

Solid-state amorphization reaction in mechanically deformed Al_xHf_1_0_0_-_x multilayered composite powders and the effect of annealing  

International Nuclear Information System (INIS)

Single phase amorphous Al_xHf_1_0_0_-_x alloys with a wide amorphization range (33#<=#x#<=#75) were synthesized by the solid-state interdiffusion of pure polycrystalline Al and Hf powders at room temperature using a rod-milling technique. The mechanisms of metallic glass formation and competing crystallization processes in the mechanically deformed composite powders were investigated by means of X-ray diffraction, differential thermal analysis, scanning electron microscopy and transmission electron microscopy. The numerous intimate layered composite particles of the diffusion couples that formed during the first and intermediate stages of milling (0-173 ks) are intermixed to form amorphous phase(s) upon heating to about 980 K by so-called thermally assisted solid-state amorphization (TASSA). The amorphization heat formation for the binary Al_xHf_1_0_0_-_x system via TASSA, #DELTA#H"T"A"S"S"A_a, was measured directly ...

1999-03-04

481

Gas fired heaters and ventilation system improve indoor air quality and thermal comfort  

Energy Technology Data Exchange (ETDEWEB)

Rotex Inc. has designed and manufactured industrial sifting equipment since 1844. This site (an existing industrial facility) encompasses approximately 140,000 ft[sup 2] (13,006 m[sup 2]) of offices, R D shops, assembly and storage areas, as well as a large welding shop that was the main focus of this project. This facility consists of three separate buildings that are all connected and open to one another. The original building dates from 1908. The newest addition (32,400 ft[sup 2]; 3,010 m[sup 2]) was added in 1977, and is referred to as the 77 Building. This building was initially equipped with oil fired heating equipment due to the moratorium on new gas sales that was in effect at that time. This project was driven by the client's need to remove underground oil storage tanks to comply with environmental standards. This article describes the 77 Building conversion from oil to an environmentally cleaner fuel, natural gas. Existing heaters were removed ...

1994-03-01

482

Dynamic response of a liquid-vapor interface during flow film boiling from a sphere  

Energy Technology Data Exchange (ETDEWEB)

Film boiling is the mode if boiling during which the hot surface is separated from the vaporizing liquid by a nearly continuous film vapor. Film boiling is usually considered a very undesirable boiling regime since it is a relatively quiet and inefficient mode of heat transfer, particularly as compared to nucleate boiling. It is customary to analyze the two-phase flow regime of laminar flow film boiling by assuming the two-phase flow regime of laminar flow film boiling by assuming an idealized vapor film flow characterized by a smooth liquid-vapor interface. However, during stable flow film boiling, the wavy nature of the liquid-vapor interface and its role in local heat and mass transport have been largely ignored. The vapor interface is rarely stationary. Interfacial waves may substantially augment the heat transfer rates throughout the layer. The present analysis treats stagnation point flow film boiling on a sphere ...

1987-11-01

483

Drying of medicinal plants with solar energy. Trocknung von Arzneipflanzen mit Solarenergie  

Energy Technology Data Exchange (ETDEWEB)

Due to the high investment and operation costs incurred by dryers up to 50% of the proceeds from the cultivation of medicinal plants have to be spent on drying. This study was conducted in order to determine whether these costs can be lowered when solar energy is used. As little is known about the drying behaviour of medicinal plants even today one selected sage and camomile in order to study the influence of temperature, relative humidity, and drying air velocity on drying time and drug quality. Laboratory results were used as a basis for developing a solar hothouse dryer for medicinal plants which uses the whole roof surface as solar collectors with a batch dryer set up within the hothouse. In contrast to dryers of this type used up to now a foil green house with a gable roof was used. Installation of a central heating system helps to avoid bottlenecks, allows drying at night and increases plant flow by a factor of 3. The cost of ...

1991-12-01

484

Development of MHD generator channel walls, 1  

International Nuclear Information System (INIS)

Experimental results of compatibility tests on ceramics-metal bonded structures performed under high heat flux conditions in splash test apparatus are reported. Emphasis is placed on results of the channel wall design and its critical operating conditions under MHD environment. The module design of one cold type and three semihot type insulators have been tested. These materials were Al_2O_3, Al_2MgO_4, LaAlO_4, MgO and Sialon ceramics. The methods of cold type ceramics-metal bonding structure were studied on Al_2O_3 and Spinel spray coating technology. The refractory metallizing and ceramics-metal graded structure manufactured by HIP technologies were applied to bonding between the MgO or LaAlO_4 and metallic cooling system. The Sialon non-bonding structure was tested with mechanical supported cooling system by shrinc fitting method. The results indicated that the bonding structures made of the MgO(MG-S) with Copper and ...

485

Supporting Thermal Hydraulic Calculations for the SGTR Event Tree of SMART Level 1 PSA  

International Nuclear Information System (INIS)

SMART (System integrated Modular Advanced ReacTor) , is under development at the Korea Atomic Energy Research Institute (KAERI). SMART is an integral type pressurized water reactor which contains a pressurizer, 4 reactor coolant pumps (RCPs), and 8 steam generator cassettes(S/Gs) in a single reactor vessel. This reactor has substantially enhanced its safety with an integral layout of its major components, 4 trains of safety injection system (SIS), and an adoption of 4 trains of passive residual heat removal system (PRHRS) instead of an active auxiliary feedwater system . The thermal power is 330 MWth. During the conceptual design stage, a preliminary PSA was performed. PSA results identified that a steam generator tube rupture (SGTR) is one of the most important initiating events which results in a high core damage frequency. Clear understanding of accident progression with various ...

2010-10-01

486

PILC cable technology and accessories  

Energy Technology Data Exchange (ETDEWEB)

Studies were conducted to examine the pressure on fluid-filled cables of electric power transmission networks in the event of an oil leak. Transition splices between paper-insulated oil-impregnated cable systems (PILC) and solid dielectric cable is difficult to perform. A proper PILC is composed of a means to contain oil within the cable structure and to keep moisture out. A failure of the cable joint could occur if an oil leak dries out the paper. Since oil pressure in most PILC cables is high, strong mechanical means must be devised to contain the oil within the cable. Resin systems, heat shrink systems and wiped lead sleeves to reseal the PILC cable over the splice, are among the methods used to stop an oil leak. A system has been designed using an EPDM tube contained under mechanical pressure; it has proven to be effective over a wide range of pressure conditions. Test results ...

1996-08-01

487

Integrated interpretation of AE clusters and fracture system in Hijiori HDR artificial reservoir; Hijiori koon gantai jinko choryuso no AE cluster to kiretsu system ni kansuru togoteki kaishaku  

Energy Technology Data Exchange (ETDEWEB)

With regard to a fracture system in the Hijiori hot dry rock artificial reservoir, an attempt was made on an interpretation which integrates different data. Major factors that characterize development and performance of an artificial reservoir are composed of a fracture system in rocks, which acts as circulating water paths, a heat exchange face and a reservoir space. The system relates not only with crack density distribution, but also with cracks activated by water pressure fracturing, cracks generating acoustic emission (AE), and cracks working as major flow paths, all of which are characterized by having respective behaviors and roles. Characteristics are shown on AE cluster distribution, crack distribution, production zone and estimated stress fields. Mutual relationship among these elements was discussed based on the Coulomb`s theory. The most important paths are characterized by distribution of ...

1997-05-27

488

Experience with fully operational solar-driven 10-ton LiBr/H2O single-effect absorption cooling system in Thailand  

British Library Electronic Table of Contents (United Kingdom)

A solar-driven 10-ton LiBr/H2O single-effect absorption cooling system has been designed and installed at the School of Renewable Energy Technology (SERT), Phitsanulok, Thailand. Construction took place in 2005, after which this system became fully operational and has been supplying cooling for our main testing buildings air-conditioning. Data on the systems operation were collected during 2006 and analyzed to find the extent to which solar energy replaced conventional energy sources. Here, we present these data and show that the 72m2 evacuated tube solar collector delivered a yearly average solar fraction of 81%, while the remaining 19% of thermal energy required by the chiller was supplied by a LPG-fired backup heating unit. We also show that the economics of this cooling system are domi...

2008-01-01

489

Design modifications in 540 MWe and its impact on the dose rates  

International Nuclear Information System (INIS)

Exposure control at the operating Nuclear Power Station is a major concern. TAPS Unit-4 is the first Pressurized Heavy Water Reactor of 540 MWe electrical capacity. This unit was made critical on March 6, 2005. In-depth review of radiation safety was done to identify the impact of design modification on dose rates at various locations and on the equipment's. Problems encountered in controlling the dose rates in 220 MWe electrical are eliminated by appropriate design modifications. Due to higher capacity of the unit there are design changes in major systems such as reactor core, primer heat transport system, moderator system, reactor regulation and protection systems. Reactor operations and maintenance activities during shut down contributes to exposure of the employees. Based on the experience gained in the operation of 220 MWe, design modifications incorporated in TAPS unit-4 and ...

2005-11-23

490

An assessment of energy options for a remote first nation community. Paper no. IGEC-1-055  

International Nuclear Information System (INIS)

Development of renewable energy systems for remote communities is gaining interest among government, utilities, NGOs and the communities themselves as a means of improving lifestyles of community members and showcasing renewable energy systems. The Huu-ay-aht First Nation, whose traditional territory is located on the west side of Vancouver Island in British Columbia, is a community which has energy related problems and energy related opportunities. The objective of this study is to assess possible energy options for the Huu-ay-aht First Nation traditional territory. Current and future energy services within the territory were used as the starting point for developing energy system options. Extensive consultation with community members was instrumental in clearly defining the objectives of the study and understanding the territory's energy demand. The energy demand assessment included an estimation of the electric, ...

2005-06-12

491

Using the alkoxomethod to obtain the oxide phases of Fe_2O_3-Y_2O_3 system  

International Nuclear Information System (INIS)

Production of Fe_2O_3, Y_2O_3, YFeO_3, Y_3Fe_5O_1_2 powders using the alkoxomethod - during hydrolysis by yttrium and iron alcohol solutions, is studied. It is stated that production of the powders of Y_2O_3-Fe_2O_3 system oxides using alkoxomethod permits to decrease essentially the reaction volumes, number of operations, their duration as compared to the cooxidation of oxide hydrates from inorganic salt aqueous solutions. During heat treatment of iron (3) alcohol hydrolysis products #gamma#-Fe_2O_3 is first crystallized by contrast to #alpha#-FeOOH, usually produced by deposition from solutions. Further heat treatment of #gamma#-Fe_2O_3 results in production of #alpha#-Fe_2O_3. Conditions for crystallization of Y_3Fe_5O_1_2 and YFeO_3 phases, prepared by both methods, and their crystallite mean sizes are close, but the powders obtained from alcohols are more homogeneous.

492

Theoretical and scaling factors methods to calculate the radioactivity in operational waste streams from Unit 1 at Cernavoda NPP  

International Nuclear Information System (INIS)

The main goal of this paper is to present a methodology for calculating the radioactivity in the moderator and heat transport systems of Cernavoda NPP Unit 1, with the intention to improve the knowledge on the radionuclides inventories in the operational waste streams, and to aid the licensing process of new near surface repository. In the present paper we describe our methodology for estimating H-3 and C-14 production rates in the heavy-water moderator and heat transport systems using the capacity factors from 1997 to 2007 years. The radioactivity of the difficult-to-measure nuclides is predicted by scaling method using measured concentration in reference CANDU 6 reactor Gentilly-2. The difficult-to-measure radionuclides of primary interest in this study were those with long half-lives which have a significant role for post-closure safety assessment. The equation used to scale fission products (parents ...

2009-05-27

493

The potential of solar-driven humidification-dehumidification desalination for small-scale decentralized water production  

Energy Technology Data Exchange (ETDEWEB)

World-wide water scarcity, especially in the developing world, indicates a pressing need to develop inexpensive, decentralized small-scale desalination technologies which use renewable resources of energy. This paper provides a comprehensive review of the state-of-the-art in one of the most promising of these technologies, solar-driven humidification-dehumidification (HDH) desalination. Previous studies have investigated many different variations on the HDH cycle. In this paper, performance parameters which enable comparison of the various versions of the HDH cycle have been defined and evaluated. To better compare these cycles, each has been represented in psychometric coordinates. The principal components of the HDH system are also reviewed and compared, including the humidifier, solar heaters, and dehumidifiers. Particular attention is given to solar air heaters, for which design data is limited; and direct air heating is compared to direct ...

2010-05-15

494

The importance of turbulence modelling in the design of a novel delivery system for a single-belt steel casting process  

Energy Technology Data Exchange (ETDEWEB)

In this work, a comprehensive model including heat transfer, fluid flow and solidification was used to evaluate the performance of a novel delivery system for a single-belt steel casting process. This near-net-shape casting, although still in development, is one of the most promising routes for casting of low-carbon steel in large scale. This paper focuses on the performance of a low-Re {kappa}-{epsilon} model that was employed to simulate the three-dimensional turbulent flows fully-coupled with heat transfer and macroscopic solidification. Simulations were run for the intended conditions of caster operation, and the results obtained with the {kappa}-{epsilon} were compared with the results obtained with an ad hoc viscosity model, where the molecular viscosity was boosted 100 times, uniformly throughout the computational domain. A semi-analytical solution was employed for validating the models and the results showed that ...

2000-01-01

495

Study on the technology of Chinese partially gasified coal fired combined cycle with a CFBC with different speeds  

Energy Technology Data Exchange (ETDEWEB)

In the research of a more efficient, less costly, more environmentally responsible and less technically difficult method for generating electrical power from coal, `the Partially Gasified Coal Fired Combined Cycle with a CFBC with Different Speeds (DFBC)` is introduced by Tsinghua University. The high efficiency cycle includes gasification, compressed air heating in a fluidized bed immersed air heater followed by a combustor and the heat recovery of gas turbine exhausted gas used as the combustion of coal in the differential-velocity atmospheric circulating fluidized bed. Superheated steam is raised in the DFBC boiler. A preliminary analysis is made for the choice of combined cycle components. The computer program can be used to evaluate the design and off-design performance of the power plant. The simulation results show that the new system is a valuable coal fired combined cycle system for China, ...

1996-12-31

496

Pitting corrosion of copper coiled tubes in the air conditioning system having the open heat storage water tank; Kaihokei chikunetsuso reionsuika ni okeru kuchokiyo kokan no koshoku ni tsuite  

Energy Technology Data Exchange (ETDEWEB)

In order to investigate pitting corrosion of copper coiled tubes for air conditioning systems with an open heat storage water tank, the effect of carbon films on the inner surface of copper tubes and fine corrosion-product particles in water as environmental corrosion factor on pitting corrosion was studied by field test under real environmental conditions. As a result, pitting corrosion of copper tubes was caused by synergistic effect of fine corrosion-product particles in water and carbon films. Generation of pitting corrosion was derived from deposition of the films and particles, while considerable growth of pitting corrosion was dependent on the particles. Time variation of spontaneous electrode potential also showed the effect of the film and particle. Pitting corrosion potential was estimated to be nearly 100mV vs. SCE. The following measures against pitting corrosion were considered to be effective: (1) Removal of the particles, (2) ...

1998-11-15

497

Modeling and evaluation of externally fired combined cycle using ASPEN  

Energy Technology Data Exchange (ETDEWEB)

A new performance model of the externally fired combined cycle (EFCC) is implemented in ASPEN (Advanced System for Process ENgineering), a chemical process simulator. The model accounts for interactions within and between approximately a dozen major process areas. The new model is applied to case studies to evaluate the sensitivity of process performance to the ranges of uncertainty in key model inputs such as heat losses, carbon conversion, and air leakage rates, and to illustrate how alternative designs, including steam injection and flue gas desulfurization (FGD), can affect plant thermal efficiency and net power output. The model results suggest that careful attention to the design of the FGD system is needed, especially with respect to reheat, and that steam injection may offer cost savings associated with reducing the size of the steam turbine with little or no penalty on plant output or plant efficiency. ...

1997-12-01

498

Heating and ventilation concept for a better room climate and for energy conservation. Part 1; Heiz- und Lueftungskonzept fuer besseres Raumklima und Energieeinsparung. T. 1  

Energy Technology Data Exchange (ETDEWEB)

Ventilation, cooling and illumination of modern high-rise office buildings with high-quality thermal insulation (average k-value 1.0 W/m12K) and high loads from office machinery (up to 20 W/m12 and beyond) are problematic even for modern facility management systems, with consequences for the building shell, heating system, and window ventilation. [Deutsch] Die Lueftung, Kuehlung und Beleuchtung moderner Buerohochbauten mit extremer Waermedaemmung (mittlerer K-Wert 1,0 W/m{sup 2}K) und hohen Bueromaschinenlasten (bis zu 20 W/m{sup 2} und mehr) verursachen auch heute noch erhebliche Probleme, obwohl die technische Gebaeudeausruestung weiterentwickelt wurde. Dies zeigt sich vor allem bei der Fassadenausbildung der Heizung und Fensterlueftung. (orig.)

1999-11-01

499

A hierarchical framework for coupling surface fluxes to atompsheric general circulation models: The homogeneity test  

Energy Technology Data Exchange (ETDEWEB)

The atmosphere and the biosphere are inherently coupled to one another. Atmospheric surface state variables such as temperature, winds, water vapor, precipitation, and radiation control biophysical, biogeochemical, and ecological processes at the surface and subsurface. At the same time, surface fluxes of momentum, moisture, heat, and trace gases act as time-dependent boundary conditions providing feedback on atmospheric processes. To understand such phenomena, a coupled set of interactive models is required. Costs are still prohibitive for computing surface/subsurface fluxes directly for medium-resolution atmospheric general circulation models (AGCMs), but a technique has been developed for testing large-scale homogeneity and accessing surface parameterizations and models to reduce this computational cost and maintain accuracy. This modeling system potentially bridges the observed spatial and temporal ranges yet allows the incorporation of ...

1993-12-31