Analysis of enclosed sodium pool fire scenario in sodium fire experimental facility
International Nuclear Information System (INIS)
Liquid sodium is used as coolant in Fast Breeder Reactors (FBR). There is a likelyhood of sodium spillage in ambient air in the Steam Generator Building (SGB) of the FBR plant. Due to high chemical reactivity with oxygen, especially at temperatures greater than 573 K, it catches fire very easily. In order to carryout safety related experimental studies for different modes of sodium fires and to develop suitable mathematical models for the assessment of their consequences, an experimental facility (SFEF, Sodium Fire Experimental Facility) is being setup a IGCAR, Kalpakkam. The SFEF is having a 540 m"3 volume experimental hall. Stainless steel linear will be provided on the inside surfaces of experimental hall walls, ceiling and floor. Analysis has been carried out for enclosed sodium pool fire scenarios in SFEF by using sodium pool fire code SOFIRE II, which estimates the thermal transients like pressure rise, gas ...
2007-04-22
Energy Technology Data Exchange (ETDEWEB)
This research aims to develop reliable, advanced system thermal-hydraulic computer code and to quantify the uncertainties of code to introduce the best estimate methodology of ECCS for LBLOCA. Although the one of best estimate code, RELAP5/MOD3.1 was introduced from USNRC, several deficiencies in its reflood model and some improvements have been made. The improvements consist of modification of reflood wall heat transfer package and adjusting the drop size in dispersed flow regime. The tome smoothing of wall vaporization and level tracking model are also added to eliminate the pressure spike and level oscillation. For the verification of improved model and quantification of associated uncertainty, the FLECHT-SEASET data were used and upper limit of uncertainty at 95% confidence level is evaluated. (Author) 30 refs., 49 figs., 2 tabs.
1994-06-01
British Library Electronic Table of Contents (United Kingdom)
Concrete is the primary material for building envelopes in some parts of the world, and its ability to store heat as well as its dynamic temperature changes will not only affect the deterioration rate of the exterior wall but will also greatly influence the energy efficiency of interior air conditioning. There are many methods for measuring the inner temperature of concrete, but they often have limitations, such as indirect estimation, cable installation requirements, high cost, or heterogeneity of the sample structure. In order to measure the internal temperature of concrete, this study integrated a Radio Frequency Integrated Circuit (RFIC) with a temperature sensor chip and embedded the device in concrete structures. A Smart Temperature Information Material (STIM) was thus developed. Thi...
2011-01-01
Interpolation theory and influence of boundary conditions on room air diffusion
Energy Technology Data Exchange (ETDEWEB)
This paper analyses the errors caused by interpolation from existing cases for assessing indoor air flow, air quality and thermal comfort in an office. A sensitivity study is then provided to determine the influence of several boundary conditions on indoor air diffusion. The research is conducted numerically by using a low-Reynolds-number k-{epsilon} model. It can be concluded that the interpolation errors caused by the variations of solar radiation, window size, heat source location due to lighting, and the surface temperatures of interior walls are small and can be quantitatively determined. But it is difficult to estimate the errors introduced by the variations of furniture location and size. (author).
1991-01-01
Hydrothermal coupling in a rough fracture
Heat exchange during laminar flow is studied at the fracture scale on the basis of the Stokes equation. We used a synthetic aperture model (a self-affine model) that has been shown to be a realistic geometrical description of the fracture morphology. We developed a numerical modelling using a finite difference scheme of the hydrodynamic flow and its coupling with an advection/conduction description of the fluid heat. As a first step, temperature within the surrounding rock is supposed to be constant. Influence of the fracture roughness on the heat flux through the wall, is estimated and a thermalization length is shown to emerge. Implications for the Soultz-sous-For\\^{e}ts geothermal project are discussed.
2006-01-01
Simplified methods in the estimation of the K-value of insulated cargo holds on ships
Energy Technology Data Exchange (ETDEWEB)
The problem of buried steelwork in cargo hold insulation has been investigated by several using empirical methods. These efforts have resulted in correction factors that serve as a useful aid in the complex task of estimating the K-value of a ship`s cargo holds for the correct dimensioning of the refrigeration plant. Today, the advent of the digital computer has established numerical methods of analysis as a common working tool among practicing engineers. For estimating the flow in cases of buried steelwork that cannot be handled by correction factors, this is an effective approach. This study is an analytical/numerical investigation of the effect that buried steelworks have on the heat leakage across cargo hold walls. It aims at providing enlightenment on the physical significance of the parameters influencing the problem and developing practically simple methods for predicting the heat leakage across the hold ...
1992-03-01
In-situ maintenance of low-Z limiters in reactors
Energy Technology Data Exchange (ETDEWEB)
In a reactor environment, the surface of a limiter or wall is primarily determined by the mechanism of erosion and deposition of surface material. It should be possible to use pellet injection to reduce net erosion to zero everywhere if low-Z materials are used for the surface. Erosion rates can, in general, be minimized by large area limiters and high plasma temperatures, which transmit power to the walls with less sputtering. Under ideal steady state conditions the wall surface is dominated by metallurgical effects in the wall.
1980-01-01
Two Dimensional CFD Analyses on the Heat Transfer for a Supercritical Pressure CO_2
International Nuclear Information System (INIS)
The Supercritical Water Cooled Reactor(SCWR) operates in a pressure around 25MPa and temperature of 293#approx#510 .deg. C. In order to study the heat transfer behaviors and good comparisons between the various fluids, a heat transfer test loop(SPHINX) using CO_2 has been constructed in KAERI as a part of international research program, I-NERI. At a supercritical pressure, the heat transfer coefficient is much larger than that estimated from the Dittus-Boelter correlation for a relatively large flow rate with moderate wall heat flux conditions. This phenomenon was explained by the rapid variations of the physical properties near the wall with the temperature. On the contrary, the heat transfer becomes worse when the bulk fluid enthalpy is below the pseudo-critical enthalpy under a low flow rate with large heat flux conditions. This phenomenon is called 'deteriorated heat transfer', ...
2005-10-27
Optimization of Hydrogen Consumption in Hydrogen Masers
... Hydro- gen gas is fed through a temperature- controlled Pd-Ag leak 161 into a cylindrical double-walled Pyrex bulb, 15 cm long and 1.9 cm in ...
1990-08-06
FINAL REPORT CONTINUOUS SCANNING METEOROLOGICAL CAMERA SYSTEM FOR ...
was deemed adequate and a cooling system designed utilizing the Melcor CP2-15- 10B thermoelectric module. Wall temperature achieved with this system was - 36 ...
Three-dimensional, three-component wall-PIV
Energy Technology Data Exchange (ETDEWEB)
This paper describes a new time-resolved three-dimensional, three-component (3D-3C) measurement technique called wall-PIV. It was developed to assess near wall flow fields and shear rates near non-planar surfaces. The method is based on light absorption according to Beer-Lambert's law. The fluid containing a molecular dye and seeded with buoyant particles is illuminated by a monochromatic, diffuse light. Due to the dye, the depth of view is limited to the near wall layer. The three-dimensional particle positions can be reconstructed by the intensities of the particle's projection on an image sensor. The flow estimation is performed by a new algorithm, based on learned particle trajectories. Possible sources of measurement errors related to the wall-PIV technique are analyzed. The accuracy analysis was based on single particle experiments and a three-dimensional ...
2010-06-15
Investigation of a mineral melting cupola furnace. Part II. Mathematical modeling
Energy Technology Data Exchange (ETDEWEB)
A mathematical model of a mineral melting cupola furnace for stone wool production has been developed for improving cupola operation. The 1-D, first-engineering-principles model includes mass and heat balances for the gas phase, five solid phases, and four liquid phases. The gas and solid/liquid phases flow countercurrently. Seven chemical reactions account for the conversions of coke, iron oxide, limestone, and gaseous species. The heterogeneous reactions of coke conversion are limited by both kinetics and mass transport. Heat transfer between phases is modeled including both convection and radiation. The model predicts gas concentrations; mass flow rates; and temperature profiles of the solid, melt, and gas in the cupola, as well as heat loss to the water-cooled walls. Inputs to the model include the coke, rock, and blast air properties, the blast air amount, and the coke percentage in the charge. The unknown model parameters are ...
2003-12-24
Corrosion resistance of austenitic steels and alloys in high temperature water
International Nuclear Information System (INIS)
An ampoule corrosion tests technique is presented for making a comparative corrosion-proof estimation of austenitic steels and alloys which are candidate materials for the ITER first wall and shield blanket. Influence of Cl"- on the rate and character of corrosion cracking has been determined. The dependence of time before destruction on Cl"- contents was obtained by experiments in twice-distilled water at a Cl"- content value of less than 0.05 mg/l. Kinetics of a corrosion crack growth has been determined by way of acoustic emission and measurement of electrical resistance. It has been revealed, that corrosion cracking of 316L and 316Ti steels in water with 100 mg/l of Cl"- takes place at temperatures over 50 C. For 316L (Russian analogue), 316Ti, 08Cr18Ni10Ti (type 304), 00Cr16Ni15Mo3Nb (type 316) steels and CrNiMo-1 (42-47%Cr, 1%Mo, Ni-base) alloy corrosion long-term strength and crack-resistance characteristics were ...
Approximate solutions to the Stefan problem with internal heat generation
Energy Technology Data Exchange (ETDEWEB)
Using a quasi-static approach valid for Stefan numbers less than one, we derive approximate equations governing the movement of a phase change front for materials which generate internal heat. These models are applied for both constant surface temperature and constant surface heat flux boundary conditions, in cylindrical, spherical, plane wall and semi-infinite geometries. Exact solutions with the constant surface temperature condition are obtained for the steady-state solidification thickness using the cylinder, sphere, and plane wall geometries which show that the thickness depends on the inverse square root of the internal heat generation. Under constant surface heat flux conditions, closed form equations can be obtained for the three geometries. In the case of the semi-infinite wall, we show that for constant temperature and constant heat flux out of the ...
2008-05-15
Unsteady state heat transfer in the vertical walls of a building
Energy Technology Data Exchange (ETDEWEB)
The unsteady state heat transfer behaviour of a vertical wall subject to the effects of uniform radiation is investigated and the dimensional analysis of combined heat transfers by conduction, convection and radiation is presented. The convective heat transfer coefficients used in the numerical model are determined experimentally by means of an assembly resembling the conditions encountered in the dwelling (variable temperatures and heat flows in time and space, wall associated with a floor, radiative flux outside the wall). In routine conditions (homogeneous wall dimensions, temperature differentials less than 40/sup 0/C), it is shown that the problem depends in practice on three parameters (instead of five) and that nomographs can give the energy accumulated in the wall as a function of its geometric and thermal charactersitics and the ...
1982-12-01
Free convection heat and mass transfer to steady flow in a semi-infinite vertical porous medium
Analytical solutions are derived for a flow in a semi-infinite vertical porous medium with heat and mass transfer. When the temperature and mass concentration are uniform a constant pressure is possible and sustains a fully developed flow. Thereafter there is a small perturbation on the wall temperature and concentration and the subsequent two-dimensional problem is tackled for a large Prandtl number, free convection parameters and small Reynolds number. The heat transfer rate at the wall is discussed quantitatively.
1988-02-01
Energy Technology Data Exchange (ETDEWEB)
The experimental survey about the heat transfer between the working fluid and the combustion chamber wall with a direct injection diesel engine has shown the production of a soot layer with increasing loads on the combustion chamber wall. Because the combustion process of methanol occurs without the formation of wall deposits, the same engine spark ignitioned with methanol at the same conditions has shown a higher heat transfer coefficient. Because the heat losses do not only depend on the heat transfer coefficient but also on the driving temperature difference between the working fluid and the combustion chamber wall, the methanol engine with corresponding process management showed lower heat losses than the diesel engine at nearly the same load. (orig./HW)
1994-04-01
Energy Technology Data Exchange (ETDEWEB)
With the combination of source ventilation and ceiling cooling for air-conditioning of working and recreation rooms, a ventilation system is available which fulfills the highest demands regarding thermal comfort. In order to utilize the advantages of this ventilation system with regard to air quality and thermal comfort to an optimum, the influence of the radiation exchange between cooling ceiling and walls on the flow in the room is investigated experimentally. Energy transfer from the walls to the cooled ceiling may result in an insufficient temperature of the walls compared to ambient air and in an upward flow on the wall surfaces (downward flow of) driven by gravity, which influences the flow pattern in the case of source ventilation. (orig.)
1993-07-01
Effect of crevice environment PH on corrosion damage of horizontal steam generator tubes
Energy Technology Data Exchange (ETDEWEB)
In support of a project on lifetime calculation experiments were carried out to evaluate the resistance to environmentally assisted cracking (EAC) of steam generator tubes during operation. Estimations of the incubation period for crack initiation and the threshold K value, K{sup Iscc}, and the crack growth rate were made to predict evolution of damage in tube walls. The paper summarizes results of experiments of C ring specimen for the initiation testing and results of SENT (single edge notch tensile) specimen for the crack growth rate (CGR) testing. The specimens were exposed to concentrated environments at elevated temperatures simulating crevice environments in secondary side crevices in horizontal steam generators. The results show that the material of SG tubes is sensitive to transgranular environmentally assisted cracking in the three basic concentrated environments used, alkaline, neutral and acid. The most ...
2002-07-01
Effect of crevice environment PH on corrosion damage of horizontal steam generator tubes
International Nuclear Information System (INIS)
In support of a project on lifetime calculation experiments were carried out to evaluate the resistance to environmentally assisted cracking (EAC) of steam generator tubes during operation. Estimations of the incubation period for crack initiation and the threshold K value, K"I"s"c"c, and the crack growth rate were made to predict evolution of damage in tube walls. The paper summarizes results of experiments of C ring specimen for the initiation testing and results of SENT (single edge notch tensile) specimen for the crack growth rate (CGR) testing. The specimens were exposed to concentrated environments at elevated temperatures simulating crevice environments in secondary side crevices in horizontal steam generators. The results show that the material of SG tubes is sensitive to transgranular environmentally assisted cracking in the three basic concentrated environments used, alkaline, neutral and acid. The most corrosive ...
2002-05-05
The possibility for formation of macro-cell corrosion in a liquid with low electrical conductivity
International Nuclear Information System (INIS)
The possibility of electrochemical corrosion of carbon steel at the rate of 3.25 x 10"-"5 A/cm"2 in water was examined under the conditions present during an accidental pipe rupture at the Mihama nuclear power plant: liquid conductivity, 7.5 #mu#S/cm; dissolved oxygen concentration, 5 ppb or less; pH 8.6#propor to#9.3; ferrous ion concentration, 20 ppb or less; temperature, 142 C. The corrosion rate of iron in a micro-cell with a dissolved oxygen reduction cathode was estimated to be only 1/400 of the preceding rate. On the other hand, that in a micro-cell with a hydrogen ion reduction cathode was estimated to be as high as 1/10 of the preceding rate, that is, 3.25 x 10"-"6 A/cm"2. Two important factors may have influenced the corrosion rate: the remarkable wall thinning, which must have been the direct cause of the rupture of the pipe, was located close to, and downstream from, an orifice; and, the ...
2011-05-01
Estimation of static formation temperatures in geothermal wells
Energy Technology Data Exchange (ETDEWEB)
Stabilized formation temperatures were estimated at different depths in 40 wells from the Los Humeros geothermal field, Mexico, using the Horner and the spherical radial flow (SRF) methods. The results showed that the Horner method underestimates formation temperatures, while the SRF method gives temperatures that are closer to the true formation temperatures. This was supported by numerical simulation of a combined circulation and shut-in period in several wells, and results for well H-26 are presented. Numerical reproduction of logged temperature is more feasible if an initial temperature profile based on the SRF method is employed instead of using an initial temperature profile based on the Horner method. (Author)
2003-05-01
International Nuclear Information System (INIS)
Thermoluminescence (TL) and Electron Paramagnetic Resonance (EPR) dosimetry were used to measure dose effects in borosilicate glass with time, from 10 minutes to #approx#60 days following exposure to a dose of up to 10,000 Rad. TL and EPR results were consistent and performed similarly, with both techniques capable of achieving an estimated limit of detection of between 50-100 Rad. Three peaks were identified in the TL glow curve at roughly 110 C, 205 C, and 225 C. The intensity of the 205 C peak was the dominant peak over the time period of this study. The stability of all of the peaks with time since irradiation increased with their corresponding temperature and little or no variation was observed in the glow curve response to a specified total dose attained at different dose rates. The intensity of the 205 C peak decreased logarithmically with time regardless of total dose. Based upon a conservative limit of detection of 330 Rad, a 10,000 ...
International Nuclear Information System (INIS)
Research highlights: #-># Morphological and chemical characterization at atomic scale of porous alumina layers anodised in ordered regimes. #-># Characterization based on the use of FEG-SEM, STEM-HAADF, STEM-EELS and STEM-X-EDS. #-># Nanoscale distribution of P-, C- and S-bearing species in the pore wall. - Abstract: Ordered porous alumina layers prepared by two-step anodising in phosphoric, oxalic and sulphuric acids have been characterized at sub-nanometer scale using electron microscopy techniques. FEG-SEM and STEM-HAADF images allowed estimating the pore size, cell wall and pore wall thicknesses of the layers. Nanoanalytical characterization has been performed by STEM-EELS and STEM-X-EDS. Detailed features of the spatial distribution of anions in the pore wall of the films have been obtained. Maximum concentration of P-species occurs, approximately, at the middle of the ...
2010-11-01
Transverse Resistive Wall Wakefunction with Inductive Bypass
Charged particle beams in circular accelerators couple with their surroundings through induced electromagnetic fields. This interaction can be described by so-called coupling impedances. In the frequency domain the impedance in connection with the bunch spectrum allows for stability analysis and estimates. However, for simulation codes one usually needs the wakefunction, the equivalent of the impedance in time domain. Recently the transverse impedance of a cylindrical pipe with arbitrary surface impedance was given by L. Vos. An expression for the wakefunction of this transverse resistive wall impedance with inductive bypass is derived here.
2003-01-01
Four loss-of-flow accidents in the SEAFP first wall/blanket cooling system
Energy Technology Data Exchange (ETDEWEB)
This report presents the thermal-hydraulic analysis of four Loss-of-Flow Accidents (LOFAs) in the first wall/blanket cooling system of the alternative SEAFP reactor design. The LOFAs considered result from a loss of electrical power for the recirculation pump in the primary cooling circuit. The analyses have been performed using the thermal-hydraulic system analysis code RELAP5/MOD3. In the analyses, special attention has been paid to the transient thermal-hydraulic behaviour of the cooling system and the temperature development in the first wall and blanket. For the LOFA without plasma shutdown, significant loss of heat removal due to dryout occurs at the midplane of the outboard first wall cooling pipes about 41 s after pump trip. For the three LOFA cases with emergency plasma shutdown that have been studied, the temperature increase in the Be-coating at the midplane of the ...
1994-07-01
International Nuclear Information System (INIS)
Natural convection of vaporizing Deuterium at 25 K transports the heat generated in the moderator cell of the cold neutron source to a He cooled condenser. The thermohydraulics of this thermosiphon were precalculated and the results verified by experiments in a 1:1 model using D_2 as fluid. The experimental results show that the thermosiphon operates stable. The demanded liquid content of the cell as well as wall temperatures below 50 K can be ensured by a proper design of the cell outlet flow geometry. A 7 min. loss of cryogenic power results in transient temperatures of the cell wall of not more than 300 K.
1991-08-01
Numerical solutions for fully developed laminar flow in internally finned tubes with trapezoidal and triangular fin profiles were given with Finite Element Method (FEM): The heat transfer characteristics were obtained and compared under the boundary conditions of uniform heat flux, uniform wall temperature, and the third boundary condition with finite wall thermal conductivity considered. The numerical results show that boundary conditions have pronounced effects on the temperature field. Furthermore, a new mechanism on the heat transfer augmentation of internally finned tubes is proposed.
1994-06-01
Free convection heat and mass transfer to steady flow in a semi-infinite vertical porous medium
International Nuclear Information System (INIS)
Analytical solutions are derived for a flow in a semi-infinite vertical porous medium with heat and mass transfer. When the temperature and mass concentration are uniform a constant pressure is possible and sustains a fully developed flow. Thereafter there is a small perturbation on the wall temperature and concentration and the subsequent two-dimensional problem is tackled for a large Prandtl number, free convection parameters and small Reynolds number. The heat transfer rate at the wall is discussed quantitatively. (author). 4 refs.
2010-06-01
Dosimetry of iodine-123 iomazenil in humans
International Nuclear Information System (INIS)
The distribution of the central benzodiazepine receptor specific ligand iodine-123 iomazenil was investigated in seven human adults from whole-body scans, blood samples and urine collected up to 24 h after injection. Using 12 source organs, the MIRD method was applied to calculate the absorbed radiation dose of the radioligand in various organs. The urinary bladder wall (0.15 mGy/MBq), lower large intestinal wall (0.071 mGy/MBq) testes (0.044 mGy/MBq) and upper large intestined wall (0.038 mGy/MBq) received the highest absorbed doses. The average effective dose equivalent of "1"2"3I-IBZM for adults was estimated to be 0.033 mSv/MBq. (orig.).
Energy Technology Data Exchange (ETDEWEB)
A new kind of receiver-reactor for high-temperature solar furnaces is proposed. The main body of the receiver component is an ellipsoid of revolution with specularly reflecting inner walls. The reactor component, a crucible, is placed at one focal point and the aperture at the other. With this arrangement, substantially all of the incident radiation from the concentrator should reach the reactor directly or after one reflection from the cavity walls. An analysis of the radiative exchange among the surfaces is presented. The analysis provides a tool for a parametric study and optimization of the design. It is found that, in contrast to that of conventional well-insulated cavity receivers, its collection efficiency is not very sensitive to the size of its aperture.
1987-10-27
Energy Technology Data Exchange (ETDEWEB)
In order to develop the filler metal for Hastelloy alloy XR structure with thick wall, the weldability and high temperature strength properties of Hastelloy alloy XR weldment were investigated using the filler metals, which were alloy-designed on the basis of multiple regression analysis. The former was examined through the chemical analysis in the deposited metal, bend test, FISCO cracking test, optical microscopy and hardness measurement. The latter was investigated by means of tensile and creep test. It was found from these results that the crack susceptibility in the weldment was apparent to be lowered without degrading the high temperature strength properties. Therefore, it is concluded that these filler metals possess excellent performance as the filler metal for Hastelloy alloy XR structure with thick wall. (author).
1991-11-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study is to identify the radiative heat transfer augmentation by a coaxial cylinder introduced in the infinite cylindrical pipe enclosing a participating gas. The gas is either a mixture of water vapor and carbon dioxide or gray. The gas is assumed to be homogeneous at a constant temperature, and has a refractive index of unity. All of the surfaces are opaque and gray, diffusely emitting and reflecting at a constant temperature. The effect of system diameter, diameter ratio, wall emittances, gas and surface temperatures, mixture component on heat transfer augmentation are studied by using the zone method with participating gas radiative properties evaluated from the weighted sum of gray gases model. From the radiative equilibrium condition, the installed wall temperature is formulated and calculated by the iteration method. If the medium is a ...
1992-10-01
Thermally developing flow in curved square ducts with internal fins
Energy Technology Data Exchange (ETDEWEB)
The laminar incompressible hydrodynamically fully developed and thermally developing flow is studied in a curved square duct with four longitudinal fins. The duct is successively subjected to constant wall temperature, to circumferentially uniform temperature and axially linearly or exponentially varying temperature. The local and fully developed Nusselt numbers are examined for various values of the Dean number and it is found that the heat transfer rate increases for high fins. The parameters that affect the entry length are studied and the fluctuations of the local Nu that appear in the entrance region are investigated. Temperature contour plots are presented for the visualization of the temperature field and functional relations for the Nusselt number are proposed in terms of the Dean and Prandtl numbers. (orig.)
2005-11-01
Energy Technology Data Exchange (ETDEWEB)
Spin-polarized liquid helium-3 is prepared by laser optical pumping in low magnetic field and at room temperature, prior to fast liquefaction of the polarized sample. The use of a new helium-3 cryostat enabled us to obtain liquid helium-3 with polarization rates up to 25 % at well-stabilized temperatures (around 0.5 K). We could thereby study the effect of nuclear polarization on liquid-vapour equilibrium, and particularly on the saturated vapour pressure. Very sensitive capacitive gauges were developed. We estimated (to first order in M{sup 2}) the expected effects when the polarization M is suddenly destroyed. These effects were experimentally observed in helium-3/helium-4 mixtures, in pure helium-3, only a transient increase in pressure has been recorded. We then describe in a third part a preliminary experiment which aimed at determining the longitudinal relaxation time T1 in mixtures. Relaxation on the ...
1999-07-15
Simulation of electromechanical and thermomechanical loads on first wall mock-ups
International Nuclear Information System (INIS)
During the operation of a tokamak, the first wall elements suffer very high heat fluxes. Heat is removed by internal cooling by means of water, helium or fluid metal. The resulting inhomogeneous temperature field cause internal stresses which, due to the pulsed operation are of cyclic nature. Additional mechanical stresses in the first wall may be caused by disruptions or vertical plasma movements. During theses events high currents are induced in the metallic part of the first wall which by their interaction with the magnetic field of the tokamak lead to mechanical forces. These electromechanical stresses may lie beyond the yield stress of the structural material. From the interaction of thermal and mechanical forces, a complex stress state is achieved which under certain circumstances may lead to premature failure and/or to progressive plastic deformations (ratcheting). In order to study the boundary ...
Energy Technology Data Exchange (ETDEWEB)
The present paper explains the curve-fitting method developed as a method to estimate the geothermal equilibrium forming temperature. In the present method, that temperature is estimated by obtaining, by non-linear lest square, the model parameter to minimize the sum of remainders squared between the temperature actually measured after a lapse of certain time from the stoppage of mud water circulation and that calculated on the basis of Middleton model, mathematical model of temperature equilibrium well. In the Horner's plotting method currently in general use, temperature recovery data during a long period of about 120h are required for estimating the geothermal equilibrium forming temperature. However in the curve-fitting method, it is confirmed from the actual well data that the well ...
1994-05-01
International Nuclear Information System (INIS)
Thermodynamic data has been selected for solids and aqueous species of technetium. Equilibrium constants have been calculated in the temperature range 0 to 300 deg C at a pressure of 1 bar for T<100 deg C and at the steam saturated pressure at higher temperatures. For aqueous species, the revised Helgeson-Kirkham-Flowers model is used for temperature extrapolations. The data base contains a large amount of estimated data, and the methods used for these estimations are described in detail. A new equation is presented that allows the estimation of #DELTA#_rCdeg_p_m values for mononuclear hydrolysis reactions. The formation constants for chloro complexes of Tc(V) and Tc(IV), whose existence is well established, have been estimated. The majority of entropy and heat capacity values in the data base have also been ...
Energy Technology Data Exchange (ETDEWEB)
Based on the CFD-code FLUENT trademark, theoretical studies were conducted of the influences of incineration chamber geometry (direct, countercurrent and center flow) on the combustion process. The boundary conditions, e.g., the thermal input and the waste grate, were kept constant. Close attention was paid to the distribution of flow, spe-cies, and temperatures. In addition, the influence of a dis-placement body at the end of the combustion chamber was tested. The variation of different wall materials and the prediction of problem areas concerning corrosion, slagging, and contamination completed the studies. Close to the chamber walls, high CO-concentrations may indi-cate corrosion; particle flow may indicate where contami-nation, slagging or erosion could occur. (orig.)
2001-01-01
Numerical simulation of slagging films in the Aachen pressurized coal combustion facility
Energy Technology Data Exchange (ETDEWEB)
Combined gas and steam turbine processes based on direct coal firing show a high thermal efficiency. At RWTH Aachen, University of Technology, an experimental test furnace has been built to investigate the pressurized pulverized coal combustion (PPCC). The PPCC-facility has been constructed as a slag tap furnace. Particles hitting the walls at temperatures above the melting point cause slagging depositions and create a film flowing down the reactor walls. As a part of the PPCC-program different mathematical models have been developed and implemented into the CFD-code FLUENT to predict the behavior of slag films at the furnace walls. Numerical strategies and the mathematical models used are described in detail. 12 refs., 9 figs.
2001-07-01
Natural convection cooling of the IFMIF target and test cell
International Nuclear Information System (INIS)
The present work summarizes efforts on the simulation of natural convection cooling within the IFMIF target and test cell. The simulations have been performed with the STAR-CD code using the k-#omega# high-Reynolds number turbulence model. A dedicated thermohydraulic model has been devised including Lithium loop components. Nuclear heat production has been calculated by the Monte-Carlo code McDeLicious for different parts of the target and test cell walls and was used as input for the STAR-CD simulations. Helium atmospheres at several pressures from 0.1 to 10"-"5 MPa have been investigated. In order to limit the maximum temperature of the concrete walls to 80 deg. C it was necessary to add thermal insulation layers to the hot Lithium loop surfaces and a conceptual system of two cooling layers in different depths of the concrete walls.
2007-10-01
Energy Technology Data Exchange (ETDEWEB)
The application of a method for determining the temperature of an oxygen-replenished air stream heated to 2600 K by a hydrogen burner is reviewed and discussed. The purpose of the measurements is to determine the spatial uniformity of the temperature in the core flow of a ramjet test facility. The technique involves sampling the product gases at the exit of the test section nozzle to infer the makeup of the reactant gases entering the burner. Knowing also the temperature of the inlet gases and assuming the flow is at chemical equilibrium, the adiabatic flame temperature is determined using an industry accepted chemical equilibrium computer code. Local temperature depressions are estimated from heat loss calculations. A description of the method, hardware and procedures is presented, along with local heat loss estimates and uncertainty ...
1995-08-01
Solar energy receiver for a Stirling engine
Energy Technology Data Exchange (ETDEWEB)
A solar energy receiver is described including a separable endless wall formed of a ceramic material having defined therein a cavity of a substantially cylindrical configuration for entrapping solar flux, and an acceptance aperture adapted to admit to the cavity a concentrated beam of solar energy, said wall being characterized by at least a pair of contiguously related segments separated by lines of cleavage intercepting said aperture, at least one of the segments being supported for pivotal displacement, and a thermal responsive actuator adapted to respond to excessive temperatures within the cavity for initiating pivotal displacement of said one segment, whereby thermal flux is permitted to escape from the cavity.
1980-12-02
Energy Technology Data Exchange (ETDEWEB)
Alpha particle confinement is necessary for ignition of a D-T tokamak fusion plasma and for first wall protection. Due to high radiation backgrounds and temperatures, scintillators and semiconductor detectors may not be used to study alpha particles which are lost to the first wall during the D-T programs on JET and ITER. An alternative method of charged particle spectrometry capable of operation in these harsh environments, is proposed: it consists of thin foils of electrically isolated conductors with the flux of alpha particles determined by the positive current flowing from the foils. 2 refs., 3 figs.
1994-07-01
The Preliminary GAMMA Code Thermal hydraulic Analysis for the Steady State of HTR-10 Initial Core
Energy Technology Data Exchange (ETDEWEB)
This report describes the preliminary thermalhydraulic analysis of HTR-10 steady state full power initial core to provide a benchmark calculation of VHTGR(Very High-Temperature Gas-Cooled Reactors) safety analysis code of GAMMA(GAs Multicomponent Mixture Analysis). The input data of GAMMA code are produced for the models of fluid block, wall block, radiation heat transfer and each component material properties in HTR-10 reactor. The temperature and flow distributions of HTR-10 steady state 10 MW{sub th} full power initial core are calculated by GAMMA code with boundary conditions of total reactor inlet flow rate of 4.32 kg/s, inlet temperature of 250 .deg. C, inlet pressure of 3 MPa, outlet pressure of 2.992 MPa and the fixed temperature at RCCS water cooling tube of 50 .deg C. The calculation results are compared with the measured solid material temperatures at ...
2006-07-15
Energy Technology Data Exchange (ETDEWEB)
This paper describes the method to estimate the true formation temperature using temperature recovery logging data after the well reach to total depth (T.D.). The method designated as ''Curve-fitting method (CFM)'' is based on mathematical model proposed by Middleton (1979, 1982). The accuracy and applicability of this method are evaluated with several field data and compared advantageously with the Horner-plot method. Then, real-time data acquisition system including interpretation software has also been successfully developed. As a conclusion, the followings are confirmed: (1) The developed CFM can be applicable to the estimation of the true formation temperature even using 24 hours temperature recovery data, although the Horner-plot method might need up to 120 hours recovery data, usually. (2) Though depending upon the ...
1995-01-26
Energy Technology Data Exchange (ETDEWEB)
The process operation of the hot wall vapor deposition method, formation of dry organic thin film and the control of molecular arrangement were described. This equipment included a substrate on the upper end of the hot wall tube and the vapor source at the lower end. The remarkable features are the hot wall tube which plays the role to hold vaporizing molecules to the high temperature and to transport molecules, and the flip flop mechanism which gives some idle period for the molecular vaporization by shutter closing. Several experiments were carried out by using stearic acid and by changing the distance S from the upper end of hot wall quartz tube to the substrate, the furnace temperature T{sub f} and the substrate temperature T{sub s}. When T{sub f} is equal to or less than the melting point of stearic acid, molectles are preferentialy ...
1991-12-01
Pressure and impulse scaling methods for wall impact in ICF (inertial confinement fusion)
Energy Technology Data Exchange (ETDEWEB)
The design of the first structural wall (FSW) in an inertial confinement fusion (ICF) reactor requires some knowledge of the expected wall loading produced by x-ray and neutron deposition; specifically in the High Yield Lithium Injection Fusion Energy (HYLIFE) reactor, wall loading results from two sources -- gas shock and liquid impact. Gas shock is derived from x-ray deposition in the thin layers of exposed blanket material, producing ionized vapor, which will generate gas shock on the FSW. Liquid impact, on the other hand, results from the acceleration of liquid blanket material by two possible forces -- the drag from vapor expansion through the blanket material and the neutron-induced isochoric disassembly process. Both impacts, however, are coupled by the interaction of hot gas expanding through the liquid blanket. This paper discusses scaling methods for estimating pressure and impulse on the ...
1990-01-01
Energy Technology Data Exchange (ETDEWEB)
The authors investigate the optimisation of solar-heated cavity receivers in which solar energy collected by a paraboloid collector is converted into electrical energy. The focussed solar energy enters the receiver through an aperture to heat the working fluid, which flows inside the receiver tubes and is compressed by the compressor of a gas turbine system, to the highest process temperature. A method of calculating the distribution on the inner receiver surfaces of the solar radiation reflected by the paraboloid collector is presented to begin with. The interchange of radiant energy inside the receiver cavity can be calculated on this basis, including the radiation loads, the temperatures of the inner receiver walls, and the radiative and convective losses. The temperature fields in the tube walls must be known for determining the strength required of receiver tubes; they can be ...
1984-01-01
Nature Of Tube Degradation In Horizontal Steam Generators
Energy Technology Data Exchange (ETDEWEB)
Nature of tube degradation was studied in support of horizontal steam generator lifetime calculations. Experiments were carried out to evaluate the resistance to environmentally assisted cracking (EAC) of steam generator tubes during operation. Estimations of the incubation period for crack initiation and the threshold K value, K(ISCC), and the crack growth rate were made to predict evolution of damage in tube walls. Experimental results were compared with in-service inspections experience. The paper summarizes results of experiments of C ring specimen for the initiation testing and results of SENT (single edge notch tensile) specimen for the crack growth rate (CGR) testing. The specimens were exposed to concentrated environments at elevated temperatures simulating crevice environments in secondary side crevices in horizontal steam generators. The results show that material of SG (steam generator) tubes is sensitive to ...
2002-07-01
Nature Of Tube Degradation In Horizontal Steam Generators
International Nuclear Information System (INIS)
Nature of tube degradation was studied in support of horizontal steam generator lifetime calculations. Experiments were carried out to evaluate the resistance to environmentally assisted cracking (EAC) of steam generator tubes during operation. Estimations of the incubation period for crack initiation and the threshold K value, K(ISCC), and the crack growth rate were made to predict evolution of damage in tube walls. Experimental results were compared with in-service inspections experience. The paper summarizes results of experiments of C ring specimen for the initiation testing and results of SENT (single edge notch tensile) specimen for the crack growth rate (CGR) testing. The specimens were exposed to concentrated environments at elevated temperatures simulating crevice environments in secondary side crevices in horizontal steam generators. The results show that material of SG (steam generator) tubes is sensitive to ...
2002-09-23
International Nuclear Information System (INIS)
Using infra-red (IR) thermography, power loads onto the MKII Gas-Box divertor targets have been investigated in Type-I ELMy H-Mode plasmas at JET in medium current discharges (Ip = 2.6 MA and BT = 2.7 T). Heat fluxes are calculated from the measured divertor target tile surface temperatures taking into account the influence of co-deposited surface layers on tile surfaces. This is particularly important when estimating the energy deposition during transient events such as ELMs. Detailed energy balance analysis is used, both from IR and tile embedded thermocouples, to demonstrate an approximately constant ELM-averaged in/out divertor target asymmetry of ?0.55 and to show that the ELM in/out energy deposition ratio ranges from 1 : 1 to 2 : 1. The inter-ELM in/out ratio is close to the ELM-averaged value at low pedestal collisionalities and decreases down to values close to zero when the inner target plasma detaches at the highest pedestal ...
2007-05-01
Steady state temperature profile in a cylinder heated by microwaves
Energy Technology Data Exchange (ETDEWEB)
A new theory has been developed to calculate the steady state temperature profile in a cylindrical sample positioned along the entire axis of a cylindrical microwave cavity. Temperature profiles were computed for alumina rods of various radii contained in a cavity excited in one of the TM{sub 0n0} modes with n = 1, 2 or 3. Calculations were also performed with a concentric outer cylindrical tube surrounding the rod to investigate hybrid treating. The parametric studies of the total sample center and surface temperatures were performed as a function of the total power transmitted into the cavity. Also, the total hemispherical emissivity was varied at boundaries of the rod, surrounding tube, and cavity walls. The results are discussed in the context of controlling the average rod temperature and the temperature distribution in the rod during microwave processing.
1995-12-31
Thermal performance and design of a solid particle cavity receiver
Energy Technology Data Exchange (ETDEWEB)
A model for energy transport in a solid particle cavity receiver is developed and applied to the design and analysis of a receiver for the Central Receiver Test Facility (CRTF), Albuquerque, New Mexico. The model gives thermal performance results - including particle temperatures, cavity efficiencies, and wall temperatures - which directly affect the economic and technical feasibility of a solid particle receiver. In addition, design criteria relevant to the configuration of a solid particle cavity receiver are developed. Results for CRTF indicate that at design conditions particle temperatures will exceed 1200/sup 0/K with cavity efficiencies on the order of 75%.
1985-04-01
Reactive sticking coefficients for silane and disilane on polycrystalline silicon
Energy Technology Data Exchange (ETDEWEB)
Reactive sticking coefficients (RSCs) were measured for silane and disilane on polycrystalline silicon for a wide range of temperature and flux (pressure) conditions. The data were obtained from deposition-rate measurements using molecular beam scattering and a very low-pressure cold-wall reactor. The RSCs have nonlinear Arrhenius temperature dependencies and decrease with increasing flux at low (710 /sup 0/C) temperatures. Several simple models are proposed to explain these observations. The results are compared with previous studies of the SiH/sub 4//Si(s) reaction and low-pressure chemical vapor deposition-rate measurements.
1988-04-15
Predictions of convective losses from a solar cavity receiver
Convective losses arising from buoyancy driven flow were calculated for a two-dimensional model simulating a solar cavity receiver. The TEMPEST code, capable of fully three-dimensional coupled thermal-hydraulic transient calculations, was used for the simulation. Predicted velocity and temperature results for a 2.59 m deep by 2.88 m high rectangular cavity with an aperture opening of 1.72 m were used to determine convective losses for prescribed interior wall temperatures and cavity orientation. Velocity vector and temperature isotherm plots were used to analyze flow characteristics.
1979-12-01
Thermal performance simulation of a solar cavity receiver under windy conditions
British Library Electronic Table of Contents (United Kingdom)
Solar cavity receiver plays a dominant role in the light-heat conversion. Its performance can directly affect the efficiency of the whole power generation system. A combined calculation method for evaluating the thermal performance of the solar cavity receiver is raised in this paper. This method couples the Monte-Carlo method, the correlations of the flow boiling heat transfer, and the calculation of air flow field. And this method can ultimately figure out the surface heat flux inside the cavity, the wall temperature of the boiling tubes, and the heat loss of the solar receiver with an iterative solution. With this method, the thermal performance of a solar cavity receiver, a saturated steam receiver, is simulated under different wind environments. The highest wall temperature of the boi...
2011-01-01
Thermal modeling of solar central receiver cavities
Energy Technology Data Exchange (ETDEWEB)
Results are presented from a numerical model of the steady-state energy transfer in molten-salt-in-tube solar cavity receivers that includes convective energy transfer at a local (spatially resolved) level. Molten salt energy absorption and gray radiative transfer between all cavity surfaces are also included. This model is applied to the Molten Salt Subsystem Component Test Experiment (MSS/CTE) cavity receiver. Results for this receiver indicate the global (entire cavity) receiver thermal efficiency is invariant within a few percent to most parameters investigated, although front surface temperatures of the nonabsorbing walls vary considerably, and are particularly sensitive to the type of convective submodel used. Absorption efficiencies indicate the effects of the cavity enclosure environment. For all conditions investigated, tube inner wall temperatures remain under 855 K, ensuring that the salt ...
1989-05-01
Forced convective heat transfer in cross-corrugated solar air heaters
Forced convective heat transfer in a cross-corrugated channel solar air heater has been studied experimentally using air as a working fluid. The channel was formed by two transversely positioned corrugated sheets and two flat thermally insulated side walls. One corrugated sheet was heated by a radiant heater, while the other was thermally insulated. The fluid velocity and temperature, and the wall temperature and the local heat flux across the heated corrugated sheet were measured for a variety of operating flow rates. Experimental results for the channel geometry have yielded the correlation Nu = 0.0743 (Re)[sup 0.76]. This heat-transfer coefficient is about 2.8 times that of a smooth flat channel. The experiments showed that local heat transfer rate was smaller on the valley of the corrugation than that on the peak. The ratio of the local heat transfer rates on the two locations was related to the ...
1994-11-01
Parahydrogen clusters: Numerical estimates and physical effects
Energy Technology Data Exchange (ETDEWEB)
We study by means of Quantum Monte Carlo simulations based on the Worm Algorithm the low temperature (down to T = 0.05 K) properties of parahydrogen clusters comprising up to 40 molecules. Three different intermolecular interactions are employed: the Silvera-Goldman, the Buck and the Lennard-Jones potential. Despite important discrepancies observed in the numerical estimates of energy and superfluid fraction, the mechanism by which clusters melt at low T is independent of the particular choice of the potential, whose only effect is to alter the temperature scale.
2009-02-01
Quantifying the thermal flowering rates of eighteen species of annual bedding plants
British Library Electronic Table of Contents (United Kingdom)
The effect of mean daily air temperature (MDT) on flowering rate (the reciprocal of days to flower) was quantified for 18 species of annual bedding plants. Plants were grown in environmental growth chambers at constant air temperature set points of 5, 7.5, 10, 15, 25, or 30^oC and under an irradiance of 160-180mmolm^-^2s^-^1, with a 16-h photoperiod. Nonlinear mathematical equations were developed to predict the effect of MDT on flowering rate and to estimate the base, optimum, and maximum temperatures (Tmin, Topt, and Tmax), which are the temperatures at which flowering rates are zero (low temperature), maximal, and zero once again (high temperature), respectively. The estimated Tmin varied among species and ranged from 1.1^oC in French marigold (Tagetes patula L.) to 9.9^oC in angelonia ...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
A special study was conducted to investigate the influences of minimum approach temperature differences occurring in supercritical-heater/vaporizer and evaporative-condenser heat rejection systems on geothermal-electric binary power plant performance and cost of electricity. For the systems investigated optimum pinch points for minimizing cost of electricity were estimated to range from 5 to 7/sup 0/F for the heater vaporizer. The minimum approach of condensing temperature to wet-bulb temperature for evaporative condensers was estimated to be about 30/sup 0/F in order to achieve the lowest cost of electricity.
1983-10-01
International Nuclear Information System (INIS)
In this paper, a phenomenological model of the thermal hydraulics of convective boiling in the post-critical-heat-flux (post-CHF) regime is developed and discussed. The model was implemented in the TRAC-PF1/MOD2 computer code (an advanced best-estimate computer program written for the analysis of pressurized water reactor systems). The model was built around the determination of flow regimes downstream of the quench front. The regimes were determined from the flow-regime map suggested by Ishii and his coworkers. Heat transfer in the transition boiling region was formulated as a position-dependent model. The propagation of the CHF point was strongly dependent on the length of the transition boiling region. Wall-to-fluid film boiling heat transfer was considered to consist of two components: first, a wall-to-vapor convective heat-transfer portion and, second, a wall-to-liquid heat transfer representing ...
1983-10-14
Loss of flow accident analysis of a water-cooled fusion reactor
International Nuclear Information System (INIS)
Within the APROS simulation environment we have built a thermo-hydraulic model of a conceptual fusion power plant which is water cooled and uses lithium-lead for tritium breeding. For the safety assessment of this design we have studied an accident sequence which starts from a loss or coolant flow then leads to first wall breach and pressurisation of the vacuum vessel. Simulations have revealed strong pressure transients which can be alleviated by design changes. One goal is to verify the adequacy of the containment design: it remains intact at least 14 h without any mitigating efforts. Estimates for radioactive releases are obtained. (author)
2003-08-25
The analysis of temperature distribution for surveillance Capsule in reactor vessel of YGN unit 1
International Nuclear Information System (INIS)
Generally, Hardening and irradiated brominating phenomena are occurred in the reactor vessel under operation conditions by atomic cavities and creation of impurity atoms which are led by high fast neutron flux. To assure the mechanical integrity of pressure vessel until the end of power plant life after monitoring the sample specimens on the vessel inside, a series of tests is performed over the retrieved surveillance capsule to examine the changes according to the plant operation in accordance with regulations. Monitoring surveillance capsules attached to neutron shield wall of outer core are consists of impact sample, tensile sample and temperature monitor
2007-05-10
Analysis of laminar flow heat transfer in uniform temperature circular tubes with tape inserts
Constant property, laminar flow heat transfer in a semicircular tube with uniform wall temperature has been analyzed to define the lower bound of heat transfer augmentation in circular tubes with twisted-tape inserts. Two thermal boundary conditions, which correspond to the two extremes of the fin effect of twisted tapes encountered in practical applications, are considered. Numerical solutions, employing finite-difference formulations for the governing momentum and energy equations were carried out for the thermal entrance region and for fully developed flow.
1986-05-01
W1045 environment surf drip shield and waste package outer barrier
Energy Technology Data Exchange (ETDEWEB)
The environments on the drip shield and waste package outer barrier are controlled by the compositions of the waters that contact these components. the temperature (T) of these components, and the effective relative humidity (RH) at these components. Because the composition of the waters that are expected to enter the emplacement drifts (either by seepage flow or by episodic flow) have not been specified: well J13 water was chosen as the reference water (Harrar 1990). Section 6.2 discusses the accessible RH for the temperatures of interest at the repository horizon. Section 6.3 discusses the adsorption of water on metal alloys in the absence of hygroscopic salts. Because the temperatures of the DSs and the WPOBs are higher than those of the surrounding near-field environment, the relative humidity at the DSs and the WPOBs will be lower than that of the surrounding near-field environment. This difference is a result of the ...
1999-07-14
British Library Electronic Table of Contents (United Kingdom)
Displacement Ventilation (DV) offers a great opportunity to improve indoor air quality while reducing the energy consumption compared to mixing ventilation. A frequent problem with displacement ventilation is however the draft discomfort caused by the cold air movement at foot level and excessive temperature difference between head and ankle. Despite numerous past studies, there is still a lack of detailed data regarding the velocity and temperature distribution inside DV jets. In this experimental study, measurements of the air velocity and temperature are performed in the DV jet produced by a flat wall-mounted DV diffuser, using a fine mesh focused on the 0.00-0.20 m height range. Two supply conditions are studied. Three planes of measurements are covered: the vertical longitudinal plane...
2012-01-01
Kinetics of low-temperature radiation hardening of metallic materials under irradiation
British Library Electronic Table of Contents (United Kingdom)
A formula is obtained which describes the kinetics of low-temperature radiation hardening caused by creation of dislocation loops of interstitial type during irradiation. The radiation hardening of aluminum and vanadium is estimated using this formula and results of experiments on studying processes of nucleation and growth of interstitial dislocation loops in these materials by transparent electron microscopy. It is shown that the proposed formula is valid for description of the kinetics of low-temperature radiation hardening.
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
An experimental study was performed to investigate the heat transfer characteristics of the mixed convection flow through a horizontal rectangular channel where open-cell metal foams of different pore densities (10, 20 and 30 PPI) were situated. A uniform heat flux was applied at all of the bounding walls of the channel. For each of three values of the uniform heat flux, temperatures were measured on the entire surfaces of the walls. Results for the average and local Nusselt numbers are presented as functions of the Reynolds and Richardson numbers. The Reynolds number based on the channel height of the rectangular channel was varied from 600 to 33000, while the Richardson number ranged from 0.02 to 103, extending over forced, mixed and natural convection. Second important parameter that in...
2009-01-01
Determining the porosity of rock in oil wells using compensated neutron logging
Energy Technology Data Exchange (ETDEWEB)
The two-sonde neutron-logging device RKS-2 registers the ratios of the indications of two sondes and is scaled in units representing the total water content of pure limestone when saturated with fresh water. When analyzing the results of the measurements in real wells, it is necessary to calculate the effect of well- and strata conditions on the results of porosity determination. The results of simulated measurements are presented, on the basis of which correction factors are immediately determined for the calculation of the effect of the diameter of the well, and the effect of the mud cake on the well wall. A nomogram is constructed and substantiated; its purpose is the calculation of the effect of the following on the RKS-2 indication: the diameter of the well, the mud cake on the well wall, the density of the drilling solution, temperature, pressure in the well, and the lithology of the rock.
1982-01-01
The optical birefringence of rod-like nematogens (7CB, 8CB), imbibed in parallel silica channels with 10 nm diameter and 300 micrometer length, is measured and compared to the thermotropic bulk behavior. The orientational order of the confined liquid crystals, quantified by the uniaxial nematic ordering parameter, evolves continuously between paranematic and nematic states, in contrast to the discontinuous isotropic-to-nematic bulk phase transitions. A Landau-de Gennes model reveals that the strength of the orientational ordering fields, imposed by the silica walls, is beyond a critical threshold, that separates discontinuous from continuous paranematic-to-nematic behavior. Quenched disorder effects, attributable to wall irregularities, leave the transition temperatures affected only marginally, despite the strong ordering fields in the channels.
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
The need to increase efficiency of volumetric receivers for use in solar power plants by reducing reradiation losses and increasing the ``volumetric effect`` has promoted the idea of a receiver with tapered ducts. These seems to be very promising since higher efficiency and considerable saving of material can be achieved, as compared to conventional receivers perforated with ducts of constant cross-section. A finite element program is being developed to calculate stationary heat transfer in the tapered ducts by free and forced convection in the gas flow, conduction in walls and in the gas, and solar and thermal radiation. Gas and wall temperatures are considered to be varying only in the flow direction. In order to perform the highly nonlinear calculations of radiative exchange, the exact knowledge of the view factors is necessary. The aim of the present work is to evaluate analytically the view factors in tapered ducts.
1995-02-01
International Nuclear Information System (INIS)
Full text of publication follows: As the coolant experiences no phase change in the core, SCWRs, unlike LWRs, cannot use design criteria based on the critical heat flux concept. The commonly accepted practice in SCWRs is to specify cladding temperature limits that must be met during transient and accident events. Therefore for the design of the SCWR, it is very important to predict the heat transfer coefficient to the supercritical water coolant with great accuracy. Our recent study focuses on the critical issue of measuring heat transfer to supercritical water at prototypical SCWR conditions and to develop the tools to predict the SCWR thermal behavior. A heat transfer test loop using a surrogate fluids, CO_2, is under construction. The reason of using CO_2 instead of water is that (i) valuable insight of the physical phenomena can be obtained with this fluid, and (ii) some existing facilities already used surrogate fluids, which in general have lower critical ...
2005-10-02
Numerical simulation of a 1200 MWth pulverised fuel oxy-firing furnace
Energy Technology Data Exchange (ETDEWEB)
The Oxycoal burner for pulverised coal combustion previously developed by the authors has been scaled up to typical power plant dimensions and a CFD study of pulverised coal combustion in a 1200 MWth oxy-firing furnace has been performed. The study revealed the importance of modelling the flue gas radiation behaviour for flue gas temperatures and wall heat transfer. This was done using a non-grey implementation of the Exponential Wide Band Model (EWBM). Typically, comparisons between air and oxy-fired furnaces point out that to obtain similar flame behaviour, the oxygen content in oxy-firing conditions should be increased until the same adiabatic flame temperature is reached. However, it was found that for these conditions, significantly increased wall heat fluxes can be the result. Furthermore, at gas temperatures comparable to air combustion, particle burnout is accelerated in ...
2009-07-01
Analysis of natural convection in narrow annular gaps of LMFBR
International Nuclear Information System (INIS)
The natural convection characteristics of gas in a vertical narrow annular gap which had its bottom opened to high temperature fluid and its upper shielding exposed to low temperature sealant have been evaluated from simulated fluid experiments using water and from calculations using the three-dimensional thermal hydraulic analysis computer code THERVIS-III. The following results were obtained: (1) The critical Rayleigh number which represented the limit of convection generation increased as the aspect ratios #epsilon#_1 (height/circumference) and #epsilon#_2 (height/gap distance) increased. (2) The flow pattern along the circumferential direction was seen to depend more strongly on the radiant heat from the side wall, rather than the aspect ratios #epsilon#_1 and #epsilon#_2. (3) The temperature difference along the circumferential direction in the annular gap obtained from the calculation code ...
Energy Technology Data Exchange (ETDEWEB)
Numerical solutions given by a vorticity-velocity method are presented for combined free and forced laminar convection in the thermal entrance region of a horizontal rectangular channel without the assumptions of large Prandtl number and small Grashof number. The channel wall is heated with a uniform wall heat flux. Typical developments of temperature profile, secondary flow, and axial velocity at various axial positions in the entrance region are presented. Local friction factor and Nusselt number variations are shown for Rayleigh numbers Ra = 10{sup 4}, 3 {times} 10{sup 4}, 6 {times} 10{sup 4}, and 10{sup 5} with the Prandtl number as a parameter. The solution for the limiting case of large Prandtl number and small Grashof number obtained from the present study confirms the data of existing literature. It is observed that the large Prandtl number assumption is valid for Pr = 10 when Ra {le} 3 {times} 10{sup 4} but for a ...
1987-08-01
Energy Technology Data Exchange (ETDEWEB)
Discussions were given on the characteristics of a diesel engine to emit unburned hydrocarbon (HC) created in a long idling operation. The engine tested in the experiment is a direct injection diesel engine with six water-cooled were investigated varying the jet hole diameter and length of the jet nozzle. In the initial operation period, the HC showed high values. This is thought because part of the injected fuel has deposited on the wall because of low combustion chamber wall temperature, and the fuel deposit that did not evaporate during combustion evaporated during expansion process and emitted unburned. The head was dismantled to investigate the carbon flowers deposited on the nozzle and the relationship between the carbon and the HC deposited on the head face and the combustion chamber wall. It was clarified that the HC increase was phenomenal compared with that of the carbon. This is because the ...
1992-04-01
Energy Technology Data Exchange (ETDEWEB)
Vanadium alloys exhibit important advantages as a candidate structural material for fusion first wall/blanket applications. These advantages include fabricability, favorable safety and environmental features, high temperature and high wall load capability, and long lifetime under irradiation. Vanadium alloys with (3-5)% chromium and (3-5)% titanium appear to offer the best combination of properties for first wall/blanket applications. A V-4Cr-4Ti alloy is recommended as the reference composition for the ITER application. This report provides a summary of the R&D conducted during 1994 in support of the ITER Engineering Design Activity. Progress is reported for Vanadium Alloy Production, Welding, Physical Properties, Baseline Mechanical Properties, Corrosion/Compatibility, Neutron Irradiation Effects, Helium Transmutation Effects on Irradiated Alloys, and the Status of Irradiation Experiments. ...
1995-03-01
Test Bed for Superconducting Materials
Energy Technology Data Exchange (ETDEWEB)
Superconducting rf cavities are increasingly used in accelerators. Gradient is a parameter of particular importance for the ILC. Much progress in gradient has been made over the past decade, overcoming problems of multipacting, field emission, and breakdown triggered by surface impurities. However, the quenching limit of the surface magnetic field for niobium remains a hard limitation on cavity fields sustainable with this technology. Further exploration of materials and preparation may offer a path to surpassing the current limit. For this purpose, we have designed a resonant test cavity. One wall of the cavity is formed by a flat sample of superconducting material; the rest of the cavity is copper or niobium. The H field on the sample wall is 75% higher than on any other surface. Multipacting is avoided by use of a mode with no surface electric field. The cavity will be resonated through a coupling iris with high-power rf at superconducting ...
2006-01-30
Energy Technology Data Exchange (ETDEWEB)
Laboratory experiments were conducted to simulate the transfer of acidic THOREX waste from Tank 8D-4 into the alkaline PUREX waste in Tank 8D-2 at West Valley. The purpose of the experiments was to explore means of minimizing the production of nitric oxide (NO) gas during mixing of the two wastes and to assess the potential for the gas to further react in the vapor space possibly leading to enhanced corrosion of the tank walls. Forty one THOREX/PUREX mixing tests were conducted to explore the effects of stirring rate, pH, THOREX addition rate, THOREX or PUREX dilution, and temperature. The two most important criteria for minimizing NO production were to maintain some degree of agitation and the keep the pH in the PUREX high, preferably >12. Steel corrosion tests were performed in the presence of low partial pressures of NO{sub 2} and liquid water or water vapor. The NO{sub 2} (from oxidation of NO in the vapor space) concentrations were ...
1995-05-01
British Library Electronic Table of Contents (United Kingdom)
Analytical relations are obtained for estimating how the distributions of temperature and heat flux vary along a steam-generating tube and how the steam-generator power output reduces due to formation and accumulation of deposits.
2007-01-01
Analytical relations are obtained for estimating how the distributions of temperature and heat flux vary along a steam-generating tube and how the steam-generator power output reduces due to formation and accumulation of deposits.
2007-12-01
PRISM 3D: Global Warming Analysis
Estimates of global warming during the mid-Piacenzian Age of the Pliocene Epoch suggest temperatures were 2 degrees C greater than today. ... million years approaches this level of warming. PRISM/Global Warmin...
Boiling heat transfer in compact heat exchangers
Energy Technology Data Exchange (ETDEWEB)
Small circular and noncircular channels are representative of flow passages in compact evaporators and condensers. This paper describes results of an experimental study on heat transfer to the flow boiling of refrigerant- 12 in a small circular tube of diameter = 2.46 mm. The objective of the study was to assess the effect of channel size on the heat transfer coefficient and to obtain additional insights relative to the heat transfer mechanisms. The flow channel was made of brass and had an overall length of 0.9 m. The channel wall was electrically heated, and temperatures were measured on the channel wall and in the bulk fluid stream. Voltage taps were located at the same axial locations as the stream thermocouples to allow testing over an exit quality range of 0.21 to 0.94 and a large range of mass flux (63 to 832 kg/m{sup 2}s) and heat flux (2.5 to 59 kW/m{sup 2}). Saturation pressure was nearly constant, averaging 0.82 ...
1994-12-31
Symplectic Integrators Designed for Simulating Soft Matter
Symplectic integrators designed for simulating soft matter at constant temperature and constant pressure (or constant surface tension) are presented. In addition to the well-known merits of symplectic integrators, such as long time stability, these methods allow the estimation of thermal heat production/absorption and thus entropy differences through a simple function of the time scaling factor ?. The relative entropy estimation around crystal-liquid phase transition is given for systems with soft core repulsive potential.
2008-04-01
Ground temperatures surrounding a molten fuel pool
International Nuclear Information System (INIS)
In the analysis of the consequences of a hypothetical meltdown accident in an LMFBR, it is important to estimate the final location of the molten fuel pool in the concrete and ground underlying the reactor vessel. The GROWS program and the AYER program have been developed to calculate the final location of the molten fuel pool as the culmination of the transient analysis of this unusual Stefan problem but these programs require extensive computational resources. The solution is provided to the concrete and ground temperatures surrounding the stationary fuel pool and the related heat flux from the pool to the ground surface outside the containment building. This solution can be used to estimate the final location of the fuel pool and to check the end results of the sophisticated programs.
1977-06-01
Energy Technology Data Exchange (ETDEWEB)
An experiment lasting a number of hours was carried out with 6 men under standardised climate chamber conditions to find out to what extent wallpaper that reflects about 65-75% in the infra-red range by comparison with normal wallpaper that reflect only 3-5% of heat, has measurable positive effects on the thermoregulation of the human body and the human sensation of temperature. The measurements of skin temperature and heat flow intensity in the deeper areas of the body and the periphery, and metabolic heat conversion measurements (indirect calorimetry) confirm that infra-red reflection of the heat irradiated from the body lead to a measurable heat recovery on the body surface with a reduction of metabolic conversion. It was proved that it is possible to reduce the average room temperature by up to 4 K whilst maintaining the same degree of thermal comfort, which corresponds to a 20% saving in heating energy. (orig./BWI).
1985-06-01
Compact Single-Stage Fuel Processor for PEM Fuel Cells. Final report
Energy Technology Data Exchange (ETDEWEB)
Based on observations during the steam reforming of ethanol, the authors conclude that carbon was forming in the steam generator due to the thermal decomposition of ethanol. Since ethanol is being thermally decomposed, they were operating the steam generator at too high of a temperature. The thermal degradation of ethanol was confirmed by using a GC with a flame ionization detector. They observed trace amounts of additional hydrocarbons other than methane in the effluent which we assume maybe ethane and ethylene. We identified the operating conditions that allowed us to steam reform ethanol for an acceptable amount of time. These conditions were a steam temperature of 200 C and a wall temperature of 400 C at the center of the reactor. The calculated ratios of CO{sub 2}/CO indicate that we can lower the potential for carbon deposition from the Boudouard further by reducing the pressure.
2000-01-01
Atomic processes in high temperature plasmas
International Nuclear Information System (INIS)
Much theoretical and experimental efforts have been expended in recent years to study those atomic processes which are specially relevant to understanding high temperature laboratory plasmas. For magnetically confined fusion plasmas, the temperature range of interest spans from the hundreds of eV at plasma edges to 10 keV at the center of the plasma, where most of the impurity ions are nearly fully ionized. These highly stripped ions interact strongly with electrons in the plasma, leading to further excitation and ionization of the ions, as well as electron capture. Radiations are emitted during these processes, which easily escape to plasma container walls, thus cooling the plasma. One of the dominant modes of radiation emission has been identified with dielectronic recombination. This paper reviews this work.
1990-01-01
Particle simulation of edge pedestal formation and plasma rotation dynamics
International Nuclear Information System (INIS)
Gyrokinetic particle simulation of edge pedestal formation and plasma rotation dynamics will be presented, and compared with experimental observations. Realistic tokamak edge geometry is used which include separatrix/X-point and material wall from EFIT g-eqdsk data. In order to handle adequately the spatially inhomogeneous electric potential in the scrape-off region, the full-f electron technique is used, in addition to the full-f ions. Monte Carlo neutral particles with wall recycling coefficient will be included self-consistently with the plasma kinetics. Ion-ion Coulomb collisions will be particle, momentum and energy conserving. Energy source for the pedestal and scrape-off plasmas is the heat flow from the core plasma, and the particle source is the ionization of the neutral atoms which are either wall recycled and/or gas puffed. The simulation will be self-consistent with the first principles nonlinear neoclassical ...
2007-03-26
Shell Temperatures for a Single-Heater Diffuser
Energy Technology Data Exchange (ETDEWEB)
A new diffuser/permeator design has been proposed for a new Savannah River Site tritium project. The use of a single heater well in the center of the shell had raised concerns that the Pd/Ag coils may be shielding radiative heat transfer to the walls thus reducing Pd/Ag tube temperatures near the shell below the recommended minimum operating temperature. The diffuser was fitted with thermocouples to measure shell temperatures during testing. Tests were run with the shell evacuated, helium feed flows of 0, 1000, and 2000 sccm; bleed pressures ranging from 0 to 203 kPa, and heater temperatures of 650, 675, and 700 degrees C. Hydrogen permeation tests were run with two hydrogen/helium mixtures and feed rates to simulate 1st and 2nd stage diffuser operations. Approximately 20 hours were required to bring the diffuser from ambient temperature to steady-state ...
2004-11-01
Soil-vegetation-atmosphere transfer modeling
Energy Technology Data Exchange (ETDEWEB)
In this study the soil/vegetation/atmosphere-model based on the formulation of Deardorff was refined to hour basis and applied to a field in Vihti. The effect of model parameters on model results (energy fluxes, temperatures) was also studied as well as the effect of atmospheric conditions. The estimation of atmospheric conditions on the soil-vegetation system as well as an estimation of the effect of vegetation parameters on the atmospheric climate was estimated. Areal surface fluxes, temperatures and moistures were also modelled for some river basins in southern Finland. Land-use and soil parameterisation was developed to include properties and yearly variation of all vegetation and soil types. One classification was selected to describe the hydrothermal properties of the soils. Evapotranspiration was verified against the water balance method
1996-12-31
British Library Electronic Table of Contents (United Kingdom)
SummaryThis paper examines the sensitivity and uncertainty of evaporation estimates from Nasser Lake, south of Egypt using data collected at the floating station Raft, 2km upstream of the Aswan High Dam, and 12 evaporation models. Based on their approach the evaporation models were ranked in five classes, respectively the Bowen ratio energy budget (BREB) approach, three energy-aerodynamic based methods, a mass transfer method, two temperature and five solar radiation-temperature approaches. State dependent parameter models were used to estimate the sensitivity indices of the different evaporation estimation methods at daily and monthly frequencies. A drastic reduction in the cost of the sensitivity analysis was obtained when coupled with efficient sampling methods, producing quasi-Monte Ca...
2010-01-01
Reliability analysis of pipe whip impacts
Energy Technology Data Exchange (ETDEWEB)
A probability-based approach is presented as the integration of probabilistic methods and deterministic modelling based on the finite element method. An existing finite element software package was linked to an existing probabilistic package to analyse the complex mechanics that occur during the transient non-linear analysis of impact problems. This methodology is applied to a pipe whip analysis of a group-distribution-header, which results from a guillotine break, and subsequent impact with the adjacent building wall; this is a postulated accident for the Ignalina Nuclear Power Plant RBMK-1500 reactors. The uncertainties of material properties, component geometry data and loads were taken into consideration. The probabilities of failure of the impacted header and of the header support-wall were estimated given uncertainties in material properties, geometrical parameters and loading. The software ProFES was used for the ...
2005-08-01
International Nuclear Information System (INIS)
In the case wherein nonlinear seismic response analyses are carried out, the response values vary due to the variations in materials and modeling. In this paper, nonlinear analyses of several random variables are carried out using: i. a conventional method; ii. a two-point estimation method (i. and ii. are simplified methods); and iii. Monte Carlo simulation (detailed method) to examine the variability of the response in the excessive nonlinear range for seismic responses of shear walls. The analyses are performed to a PWR-3 loop type reactor building which is one of the most typical reactor buildings in Japan. The variations are considered in specified compressive strength of concrete, concrete damping factor, shear wave velocity of soil and shapes of shear stress-strain relation curves of shear walls. As the results by the two simplified methods closely matched the Monte Carlo simulation results, the appropriateness for ...
1993-08-15
A study of Two-Phase Flow Regime Maps in Vertical and Horizontal Pipes
Energy Technology Data Exchange (ETDEWEB)
A safety analysis code to design a pressurized water reactor and to obtain the licences including entire proprietary rights is under development in domestic research and development project. The purpose and scope of this report is to develop the flow regimes related models for inter-phase friction, wall frictions, wall heat transfer, and inter-phase heat and mass transfer in two-phase three-field equations. In order to choose choose the flow regime criteria, we have investigated various exiting best-estimate T/H codes in this chapter 2. They are the RELAP5-3D, TRAC-M, CATHARE, MARS codes. Around 500 references used in these codes have been collected and reviewed. Also we have investigated eleven papers in detail. In chapter 3, based on the selected flow regimes, the flow regime maps for a gas-liquid flow in horizontal and vertical tubes have decided including the mechanisms of flow regime transition regions. Conclusively, ...
2007-10-15
Energy Technology Data Exchange (ETDEWEB)
A one-dimensional thermal model is derived to describe the temperature field around a vertical borehole heat exchanger (BHEx) for a geothermal heat pump. The inlet and outlet pipe flows are modeled as one, and an effective heat capacity is added to model the heat storage in the fluid and pipes. Parameter estimation techniques are then used to estimate various parameters associated with the model, including the thermal conductivity of the soil and of the grout which fills the borehole and surrounds the u-tube. The model is validated using test data from an experimental rig containing sand with known thermal conductivity. The estimates of the sand thermal conductivity derived from the model are found to be in good agreement with independent measurements.
1998-11-01
Energy Technology Data Exchange (ETDEWEB)
A one-dimensional thermal model is derived to describe the temperature field around a vertical borehole heat exchanger (BHEX) for a geothermal heat pump. The inlet and outlet pipe flows are modeled as one, and an effective heat capacity is added to model the heat storage in the fluid and pipes. Parameter estimation techniques are then used to estimate various parameters associated with the model, including the thermal conductivity of the soil and the grout that fills the borehole and surrounds the U-tube. The model is validated using test data from an experimental rig containing sand with known thermal conductivity. The estimates of the sand's thermal conductivity derived from the model are found to be in good agreement with independent measurements.
1999-01-01
An economic planning tool for geothermal energy projects
Energy Technology Data Exchange (ETDEWEB)
Three geothermal direct heat applications were examined to derive a set of cost estimates from which one could determine the effect of changes in system parameters (temperature, flow, load, etc.) on the cost of heat. For each application, a set of resource characteristics and system inputs were chosen to best represent a site specific baseline condition. The baseline estimated cost of heat was calculated along with other cost estimates representing optimistic and pessimistic conditions, bracketing the range any input variable might reasonably take. Regression equations based upon these cost estimates were developed for each application to quantitatively relate changes in cost to changes in the input variables. These three equations and their accompanying nomographs serve as easily understandable planning tools for direct heat geothermal energy projects.
1980-12-01
Evaluation of a temperature model of the continuous steel casting process
Energy Technology Data Exchange (ETDEWEB)
This report summarizes some experiences gathered when using the semi-empirical temperature model that forms the heart of the steel casting advisory system `TUNDTEMP` in simulating the casting process. The model estimates the evolution of the liquid steel temperature in a tundish of a continuous casting machine through a temperature prediction at a couple of central time instants during the casting process. The results are compared with corresponding actual observations during the castings - measured steel temperatures and recorded casting difficulties and interruptions. Explanations for the possible discrepancies are suggested. Starting from a heuristically chosen set of model parameter values, some developing steps have been tested to reduce the simulation errors. The study concentrates mainly on temperature predictions for single heat castings. At the end of ...
1993-11-01
Thermal aging of cast stainless steels in LWR systems: Estimation of mechanical properties
Energy Technology Data Exchange (ETDEWEB)
A procedure and correlations are presented for predicting Charpy-impact energy, tensile flow stress, fracture toughness J-R curve, and J{sub IC} of aged cast stainless steels from known material information. The ``saturation`` impact strength and fracture toughness of a specific cast stainless steel, i.e., the minimum value that would be achieved for the material after long-term service, is estimated from the chemical composition of the steel. Mechanical properties as a function of time and temperature of reactor service are estimated from impact energy and flow stress of the unaged material and the kinetics of embrittlement, which are also determined from chemical composition. The J{sub IC} values are determined from the estimated J-R curve and flow stress. Examples of estimating mechanical properties of cast stainless steel components during reactor service are presented. A common ...
1991-11-01
International Nuclear Information System (INIS)
When liquids are confined in nano-scopic dimensions, their properties differ from the corresponding bulk liquid, due to their reduced dimensionality and surface effects. Phase transition temperatures and pressures are often shifted from the bulk values and new phases can appear due to the strong interactions of the molecules with the confining walls. We have studied the structural and dynamical properties of aromatic liquids such as benzene, toluene, and ortho-terphenyl confined in nano-porous materials, MCM-41 and SBA-15, synthesized and characterized in our laboratory. A non-trivial dependence of the glass transition temperature, Tg, on the pore size and surface treatment of nano-porous materials is confirmed and interpreted as resulting from a competition between the fluid-wall and fluid-fluid intermolecular interactions. An increase of Tg is observed for small pore sizes and attractive surface while ...
2006-01-01
Polarization of electron cyclotron emission spectra in LHD
Energy Technology Data Exchange (ETDEWEB)
Electron cyclotron emission (ECE) can be used to determine the electron temperature profile in magnetized plasmas. The complex structure of the magnetic field configuration in the Large Helical Device (LHD), which has a large shear, complicates the analysis of the ECE spectrum. In a sheared magnetic field the propagation of X and O-mode polarization through the plasma are coupled, causing mode conversion and polarization rotation. Mode scrambling is also caused by wall reflections. In this report, this mode conversion in LHD is numerically analyzed. It was found that at low density mode conversion scrambles the ECE spectra. However, at higher density (n{sub eo} > 1.0{center_dot}10{sup 19} m{sup -3}) the polarization mode is found to rotate with the sheared magnetic field, yielding only a negligible mode conversion. Wall reflections are found to depolarize the ECE spectrum. Notwithstanding the LHD magnetic ...
1999-07-01
Energy Technology Data Exchange (ETDEWEB)
Flow fields, temperature distributions, and particle trajectories in a 2-stage entrained-flow gasifier are calculated using a CFD code, FLUENT. Realizable k- {epsilon} model is used as a turbulent model. Because of swirling flow there appear recirculation regions near the burners. The characteristics of flow fields and temperature distributions in the gasifier are dependent on the swirl number of the system. Mean residence time of the particles in the reductor is inversely proportional to particle size, particle density and swirl number. As the swirl number is increasing, the particles injected from the combustor burners approach the wall near the combustor burners, which prevents the particles from entering the reductor and thus attaching the reductor wall. If the lower combustor burner angle is larger than the higher combustor burner angle for a given swirl number, the particles may move toward the ...
2001-07-01
A new method of heat transfer augmentation by means of foreign gas jet impingement in liquid bath
International Nuclear Information System (INIS)
The authors discuss a two-phase two-component experimental system developed to study enhancement of heat transfer from a vertical chip size heater to surrounding liquid (Freon 113 or Ethanol) due to air jet impingement. Heat transfer coefficient was measured as function of jet velocity, heat flux and the distance between exit of jet tube and heated surface. The injector was placed very close to the hot surface. It was found that the heat transfer was notably enhanced with foreign gas impingement, especially in the cases of small temperature differences between wall and coolant. In fact for higher jet velocities the heat transfer coefficients tended to infinite while the temperature differences between wall and coolant were zero. The heat transfer coefficients decreased with the increasing of heat flux. High-speed camera was used to study the behaviour of the gas bubbles which play very important role in ...
1985-10-01
Energy Technology Data Exchange (ETDEWEB)
The conceptual design, parametric analysis, cost and performance analysis, and commercial assessment of a 100-MWe line-focus solar central receiver power plant are reported. This volume contains the appendices: (a) methods of determination of molten salt heat-transfer coefficients and tube-wall temperatures, (b) inputs for STEAEC programs, (c) description of system analysis computer program, (d) receiver analysis program, and (e) heliostat production plan and design methodology. (WHK)
1980-04-01
Application of light microscopy to direct coal liquefaction research
Energy Technology Data Exchange (ETDEWEB)
Light microscopy was used to analyze the effects of added catalyst at different conditions (temperature and reaction times) in liquefaction testing of a low pyritic sulfur bituminous coal. Quantitative changes in vitrinite/vitroplast reflectance of coal and liquefaction residues were shown to be useful markers in analyzing and understanding the role of catalyst during the initial stage of coal particle hydrogenation. Lower reflectance values corresponded to increased conversions up to about the 60 min and 375{degrees}C experimental conditions. Microscopical observation of liquefaction residues also revealed the presence of `wall scales` of varying width.
1998-01-01
Energy Technology Data Exchange (ETDEWEB)
This paper describes estimation of a stress field in the earth`s crust in the Kakkonda geothermal field. Formation micro imager (FMI) logging known as a crack detecting logging was performed in the well WD-1. This FMI logging has made observation possible on cracks along well axis thought to indicate size and direction of the crust stress, and drilling-induced tensile fractures (DTF). It was verified that these DTFs are generated initially in an azimuth determined by in-situ stress (an angle up to the DTF as measured counterclockwise with due north as a starting point, expressed in {theta}) in the well`s circumferential direction. It was also confirmed that a large number of cracks incline at a certain angle to the well axis (an angle made by the well axis and the DTF, expressed in {gamma}). The DTF is a crack initially generated on well walls as a result of such tensile stresses as mud pressure and thermal stress acting on the well ...
1997-05-27
Performance of a commercial heat pipe under operational conditions
Energy Technology Data Exchange (ETDEWEB)
The performance of a commercial heat pipe was investigated both experimentally and theoretically. The effect of the temperature difference, the surface area ratio, and the operational conditions on the performance were studied. The heat flow rate and the vapor temperature were estimated on a ready-made commercial heat pipe. Its performance varied considerably with operational conditions. Theoretical consideration of a mathematical model and several nomographs are also presented. This work is applicable to the design and use of heat pipes in the field.
1983-04-01
Lattice parameters and thermal expansion of solid ortho-deuterium
Energy Technology Data Exchange (ETDEWEB)
X-ray results on the lattice parameters, molar volume and thermal expansion coefficients of solid ortho-deuterium for the region from 2 K to the melting point are reported. It is found that the thermal expansion of ortho-deuterium crystals, similarly to parahydrogen is essentially anisotropic near the melting temperature. The vacancy density at the triple point is estimated. Some thermodynamic characteristics of ortho-deuterium are calculated and temperature dependences of heat capacity at constant volume, isothermal compressibility and Gruneisen constant are analyzed.
1984-01-01
Adiabatic flame temperature estimates of lean fuel/air mixtures
Energy Technology Data Exchange (ETDEWEB)
This paper reports new formulas of adiabatic flame temperature. They are functionally expressed in terms of fuel/air ratio, reaction pressure, and the number of carbon atoms in the individual fuel. Among the fuels presently considered for the formulas are members of paraffin, aromatic and olefin families, acetylene, alcohols, and hydrogen.
1983-01-01
Development of an inactive heat removal system for high temperature reactors
International Nuclear Information System (INIS)
Growing public and political interests towards incorporating passive safety features in nuclear installations, let Siempelkamp in late 1987 propose a solution consisting of a prestressed cast-iron pressure vessel and a passive heat removal system, integrated in the reactor cell surrounding the vessel. This solution combines the inherent safety of a prestressed metallic pressure vessel with the advantages of a passive heat removal system and thus constitutes a major step towards the goal of further reducing potential residual risks. The design had to meet the boundary conditions for reactor core and reactor building of the modular 200 MWth pebble bed reactor of Siemens/-KWU. The engineering design showed that many input parameters needed for the finite-element-analysis of the overall structure required a verification by measurements in a well scaled test setup. This was especially required for the heat transfer from the liner of the prestressed cast-iron pressure vessel to the natural ...
1994-08-01
Heat transfer augmentation by gas-particle two-phase flow
International Nuclear Information System (INIS)
The helium-cooled HTGR (High Temperature Gas-cooled Reactor) will take an important position in the global energy strategy. It is expected to supply not only electricity but also high quality thermal energy for various industries and local utilities without exhausting any green house effect gas or acid rain gas. The key R and D issue of the HTGR is economical competitiveness, particularly against light water reactors. Due to the poor heat transfer of the single phase helium, the HTGR's volumetric power density is restricted to tenth of corresponding PWR's value so that increasing the power density by improving heat transfer is strongly desired. The standstill can be broken through by adopting gas-solid suspension medium. Its heat transfer performance is quite excellent. Its heat capacity can be increased drastically without excessive pressurization. Although the thermal radiation is a dominant heat transfer mode in high temperature region, the ...
1995-06-01
Energy Technology Data Exchange (ETDEWEB)
Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic scattering is estimated to be extremely weak and higher S/N of ...
2009-02-21
International Nuclear Information System (INIS)
Potassium clusters arrayed in zeolite A are known to show ferromagnetic properties at low temperature. The origin of the spontaneous magnetization has been explained by a model of spin-canting in an antiferromagnetically ordered state. The direct information for the magnetic structure, however, has not been obtained so far. In the present work, we measure the neutron powder diffraction by using pulsed neutron source at KEK-KENS below and above the Curie temperature. No significant temperature-dependence was, however, obtained within the statistical errors, namely, magnetic scattering could not be detected separately. We also estimate the intensity of magnetic scattering by assuming some possible magnetic structures with considering the magnetic form factor of the cluster wave function. The intensity of magnetic scattering is estimated to be extremely weak and higher S/N of ?104 or ...
2009-02-21
Ideal Magnetohydrodynamics Stability Spectrum with a Resistive Wall
Energy Technology Data Exchange (ETDEWEB)
We show that the eigenvalue equations describing a cylindrical ideal magnetophydrodynamicsw (MHD) plasma interacting with a thin resistive wall can be put into the standard mathematical form: ??? = ??? ?. This is accomplished by using a finite element basis for the plasma, and by adding an extra degree of freedom corresponding to the electrical current in the thin wall. The standard form allows the use of linear eigenvalue solvers, without additional interations, to compute the complete spectrum of plasma modes in the presence of a surrounding restrictive wall at arbitrary separation. We show that our method recovers standard results in the limits of (1) an infinitely resistive wall (no wall), and (2) a zero resistance wall (ideal wall).
2008-05-22
Energy Technology Data Exchange (ETDEWEB)
In the context of the research project, the physical basis of the direct decoupling of highly concentrated solar radiation in materials without the detour via absorbing heat exchanger walls was examined. Also, the first chemical processes suitable for the effective long-term storage of solar energy were analysed, relevant experiments were carried out and the necessary receiver techniques for high temperature applications were provided. The principle of direct coupling was examined on fluidized beds on the one hand and on cavity receivers, on the other hand. The contribution shows the results achieved in detail. It is recorded that first processes for storing solar energy in chemical reactions were able to be examined. Alkaline earth hydroxides accommodated in ceramic honeycomb structures seem to be possible as stores for medium temperature ranges around 500deg C. Investigations on receiver structure materials are also ...
1988-03-01
Radiometric measurement of temperature distributions in solar cavity receivers
Energy Technology Data Exchange (ETDEWEB)
An engineering tool incorporating a scanning infrared radiometer, an image digitizer, a microcomputer, and the software to drive the system was developed to allow remote mapping of the temperature distribution in solar cavity receivers. Using enclosure analysis, the infrared image processing program extracts the irradiance map from the radiosity map of the cavity to yield an emissive power map. Using the calibration curve of the radiometer and the emissivity of the surface of the cavity, the emissive power map is transformed into a temperature map. The system was tested by comparing its calculated temperatures to temperatures measured by thermocouples at several locations on the surfaces of heated model cavity receivers. The average relative error for the cavities ranged from 4.6%--34.9%, with the relative error on the base usually less than half that on the wall. Some work was also ...
1989-03-01
International Nuclear Information System (INIS)
Type 316 stainless steel is the primary candidate austenitic structural material for fusion first wall constructions. Here, type 316L(N) stainless steel plate material has been irradiated up to 10 dpa at temperatures of 80, 225, 325, and 425 C in the High Flux Reactor (HFR) of Petten. Tensile tests have been performed in the temperature range from RT to 575 C at a conventional strain rate of 5 x 10"-"4 s"-"1. The results of the tensile tests are analyzed in terms of irradiation hardening and loss of ductility due to irradiation. Tensile properties saturate in the early stage (within 0.65 dpa) at the lowest applied irradiation temperature. It is indicated that the most severe degradation of tensile ductility occurs in the temperature range of 275 to 350 C. Comparison with literature data revealed a large scatter in irradiation hardening at irradiation ...
1994-06-20
Evaluation on the formability of magnesium alloy, AZ31
Energy Technology Data Exchange (ETDEWEB)
Magnesium is known to have poor formability at room temperature, mainly attributed to its hexagonal lattice structure. This paper presents the findings generated from development of warm forming to produce thin-walled magnesium components. Finite element analysis was conducted to evaluate the formability of the material and the simulated results were compared to the tensile results and product formability. Tensile tests were used to verify the formability of the sheet metal at difference temperatures. The process parameters considered in the feasibility study were forming temperature, in the range of 28 C to 300 C and magnesium sheet (AZ31B-H24) thickness, in the range of 0.4 mm to 1 mm. Magnesium hand phone covers of a thickness down to 0.4 mm have been successfully produced. The feasible forming temperature was found to be between 200 C and 250 C. Metallographic examination shows ...
2003-07-01
Video and seismic observations of Strombolian eruptions at Erebus volcano, Antarctica
British Library Electronic Table of Contents (United Kingdom)
Between 1986 and 1990 the eruptive activity of Erebus volcano was monitored by a video camera with on-screen time code and recorded on video tape. Corresponding seismic and acoustic signals were recorded from a network of 6 geophones and 2 infrasonic microphones. Two hundred Strombolian explosions and three lava flows which were erupted from 7 vents were captured on video. In December 1986 the Strombolian eruptions ejected bombs and ash. In November 1987 large bubble-bursting Strombolian eruptions were observed. The bubbles burst when the bubble walls thinned to ?20?cm. Explosions with bomb flight-times up to 14.5?s were accompanied by seismic signals with our local size estimate, ?unified magnitudes?? (mu), up to 2.3. Explosions in pools of lava formed by flows in the Inner Crater were co...
2008-01-01
Shielding augmentation for HFU penetration in calandria vault of 540 MWe PHWR
International Nuclear Information System (INIS)
This paper consists the radiation streaming analysis of Horizontal Flux Unit (HFU) penetrations in Calandria Vault of 540 MWe PHWR. There are total 7 HFU penetrations on west wall of calandria vault. As these penetrations are in accessible area, a detailed analysis has been carried out to find the neutron and gamma dose rates around these penetrations when reactor is operating. Analysis has been carried out Using the computer code MCNP and DOT-III. Based on the predictions at HFU penetrations, shielding arrangement was recommended. Neutron and gamma dose rate higher than estimated were observed at TAPS-4. This was because of installed shield not being similar to recommended one due to site conditions. Subsequently semi-empirical calculations using measured data were carried out by MCNP to further augment the existing shield taking into consideration the space limitations at site. (author)
2006-11-13
International Nuclear Information System (INIS)
A comprehensive assessment on the eligibility of reduced activation (RA) steels as structural chamber material in Inertial Fusion Energy thick-liquid concepts is performed. As far as alloying elements, it is shown that the activation of tungsten is a question to discuss. Regarding impurity elements, it is analyzed if they could question the possibility of obtaining real RA steels for shallow land burial (SLB). The effect of the thickness of the liquid wall on the SLB response of alloying and impurity elements is computed. It seems that a reasonable liquid thickness of about 80 cm is allowable to obtain SLB acceptability of real RA steels. And above all, we have estimated the impact of cross section uncertainties when addressing the former questions, and we identify those to be improved. The necessary improvement of some tungsten and niobium cross sections is justified. (authors)
2006-06-01
Mechanical design of a PERMCAT reactor module
International Nuclear Information System (INIS)
The PERMCAT is a membrane reactor proposed for processing fusion reactor plasma exhaust gas: tritium removal is obtained by isotopic swamping operating in counter-current mode. In this work, a membrane reactor using a permeator tube of length about 500 mm produced via diffusion welding of Pd-Ag thin foils is described. An appropriate mechanical design of the membrane module has been developed in order to avoid any significant compressive and bending stresses on the very long and thin wall permeator tube: two expanded bellows have been applied to the Pd-Ag tube, so that it has been pre-tensioned before operating. The elongation of the metal permeator under hydrogenation has been theoretically estimated and experimentally verified for properly designing the membrane reactor.
2007-02-01
Carbon dioxide adsorption on carbon nanomaterials
British Library Electronic Table of Contents (United Kingdom)
The adsorption of CO2 on a number of activated carbons, thermal carbon black, and oxide materials at 195 K was studied using static and dynamic techniques. The landing surface areas ?(CO2) ? 0.19 nm2 on thermal carbon black and the absolute values of sorption for P/P 0 < 0.4 were determined. The density of adsorbed CO2 in the micropore volume was estimated at ?(CO2) = 0.91 g/cm3. It was demonstrated that the previously found effect of a weakening of the sorption interaction of nitrogen molecules with thin-walled materials (which manifested itself in an analysis of sorption isotherms by a comparative method) was pronounced to a lesser degree for the sorption of CO2. At the same time, the presence of supermicropores in activated carbon samples resulted in overestimated values of surface area...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
Characteristics of pressure drop and heat transfer have been investigated for a lithium single-phase flow and a helium-lithium two-phase flow in a horizontal conducting circular channel in the presence of a uniform transverse magnetic field up to 1.4 T as related to the lithium cooling for magnetic-confinement fusion reactors. By the application of the magnetic field to the lithium single-phase flow, remarkable heat transfer enhancement has been observed at the top wall due to the suppression of the mixed convection occurring in the low Peclet number range, while appreciable heat transfer deterioration appeared in the high Peclet number range. It has been confirmed that the helium-lithium two-phase flow can reduce the high magnetohydrodynamic (MHD) pressure drop in a lithium single-phase flow, and it can provide much better heat transfer performance than that in a helium single-phase flow. In the presence of the magnetic field, heat transfer coefficient drastically ...
1998-09-01
Energy Technology Data Exchange (ETDEWEB)
A new characteristics temperature, an adiabatic limit flame temperature, was proposed as the basis to evaluate an effective energy emission and to examine a self combustion limit. Its characteristics were discussed using the reaction system between diatomic molecules as an example, and the low calorific limit of flammability was also discussed. Since the adiabatic limit flame temperature was the inherent temperature of a combustible mixture based on the thermochemical properties of constituents, it was, in particular, very important as considering a combustion system with energy recirculation between products and reactants. The available energy and efficiency of the combustion system should have been estimated on the basis of this temperature, instead of on an adiabatic flame temperature. It was also considerably high even in an extremely ...
1990-01-25
Phase change characteristic study of spherical PCMs in solar energy storage
Energy Technology Data Exchange (ETDEWEB)
This paper investigates the phase change behavior of 65 mol% capric acid and 35 mol% lauric acid, calcium chloride hexahydrate, n-octadecane, n-hexadecane, and n-eicosane inside spherical enclosures to identify a suitable heat storage material. Analytical models are developed for solidification and melting of sphere with conduction, natural convection, and heat generation. Both the models are validated with previous experimental studies. Good agreement was found between the analytical predictions and experimental study and the deviations were lesser than 20%. Heat flux release at the wall, cumulative energy release to the external fluid, are revealed for the best PCM. The influence of the size of encapsulation, initial temperature of the PCM, the external fluid temperature on solidified and molten mass fraction, and the total phase change time are also investigated. (author)
2009-08-15
Examinations of polished and dry cut sections of feed and tuyere coke revealed some possible mechanisms for the physical influence of mineral compounds on the reactivity and strength of coke. It was observed that rounded particles of mineral phases that are exposed to the pore walls and surface of coke at high temperature create an inorganic cover, thus reducing the surface available for gas-solid reactions. The particles of mineral matter that have a low melting point and viscosity can affect the coke at earlier stages in the blast furnace process, acting in the upper parts of the blast furnace (BF). The temperature-driven redistribution of mineral phases within the coke matrix probably leads to the creation of weak spots and in general to anisotropy in its properties, thus reducing its strength. 9 refs., 2 figs., 1 tab.
2006-12-15
Mass transfer in horizontal flow channels with thermal gradients
Energy Technology Data Exchange (ETDEWEB)
Mass transfer to a wall of a horizontal rectangular channel reactor was investigated by the limiting current technique for Reynolds numbers ranging from 200 to 32000. Overall mass transfer coefficients at various mass transfer surface angles were obtained while the reactor was operated under isothermal and non-isothermal conditions. Dimensionless correlations were developed for isothermal flows from 25 to 55{sup o}C and for non-isothermal flows with applied temperature differences up to 30{sup o}C. In the laminar flow range natural convection dominated, but under turbulent conditions combined natural and forced convection prevailed. Mass transfer was approximately doubled under optimum selection of channel surface rotation, temperature gradient and flow rate. (author)
1997-12-15
Mass transfer in horizontal flow channels with thermal gradients
International Nuclear Information System (INIS)
Mass transfer to a wall of a horizontal rectangular channel reactor was investigated by the limiting current technique for Reynolds numbers ranging from 200 to 32000. Overall mass transfer coefficients at various mass transfer surface angles were obtained while the reactor was operated under isothermal and non-isothermal conditions. Dimensionless correlations were developed for isothermal flows from 25 to 55"oC and for non-isothermal flows with applied temperature differences up to 30"oC. In the laminar flow range natural convection dominated, but under turbulent conditions combined natural and forced convection prevailed. Mass transfer was approximately doubled under optimum selection of channel surface rotation, temperature gradient and flow rate. (author)
1997-12-01
Influence of recycling and temperature on the swelling ability of paper
British Library Electronic Table of Contents (United Kingdom)
Hornification is the loss of fiber wall swelling which is detrimental to subsequent recycling resulting from drying. It is known that dried fibers lose their conformability and swelling capacity. The effect of recycling treatment on the swelling ability of hardwood bleached kraft pulp fibers was determined. Modelling paper recycling, sheets were recycled using heat treatment (23?C, 60?C, 100?C). The results were compared with those for natural fibers from bleached kraft pulp. Swelling kinetics of sheets was measured by a modified method monitoring interactions of pulp with water. Swelling ability decreased during the recycling in comparison with never-recycled pulp at all temperatures. Recycling of sheets caused only small changes in the cupri-ethylene-diamine viscosity, however, the water...
2011-01-01
A cone concentrator for high-temperature solar cavity-receivers
Energy Technology Data Exchange (ETDEWEB)
A cone concentrator combined with a solar cavity receiver is presented and its performance compared to a single cavity receiver. For both cases the available heat sink within the receiver is calculated. The cone concentrator suffers from a high amount of rejected rays if the exit aperture is made too small. A larger exit aperture on the other hand increases the thermal losses of the cavity. The optimum cone geometry therefore has to be found taking also into account a model of the cavity. Different operating temperatures and different values of absorption coefficients of the cavity walls are considered. A cone concentrator was built and tested at the solar furnace in Cologne. It transmits 97 percent of the rays entering the entrance aperture, which is in exact agreement with the theoretical predictions. (author)
1999-01-01
Rate of egg maturation in marine turtles exhibits -universal temperature dependence-
British Library Electronic Table of Contents (United Kingdom)
Summary 1.-The metabolic theory of ecology (MTE) predicts that, after correcting for body mass variation among organisms, the rates of most biological processes will vary as a universal function of temperature. However, empirical support for -universal temperature dependence- (UTD) is currently equivocal and based on studies of a limited number of traits. 2.-In many ectothermic animals, the rate at which females produce mature eggs is temperature dependent and may be an important factor in determining the costs of reproduction. 3.-We tested whether the rate of egg maturation in marine turtles varies with environmental temperature as predicted by MTE, using the time separating successive clutches of individual females to estimate the rate at which eggs are formed. We also assessed the pheno...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Inverse and direct methods have been used to analyze a large number of borehole temperature logs in order to infer past climatic changes. Results indicate a warming of 1-2[degree]C in eastern and central Canada during the past 150 years. A period of cooling between 500 and 200 years before present, corresponding to the time of the Little Ice Age, has also been identified in the same areas. A regional ground temperature history is estimated for eastern and central Canada from the simultaneous inversion of several temperature logs. The inferred temperature changes appear correlated with the concentration of atmospheric carbon dioxide as reported from a Greenland ice core, and agree with existing meteorological and dendrochronological records for the area.
1992-12-01
A new method for adiabatic flame temperature estimations of hydrocarbon fuels
Energy Technology Data Exchange (ETDEWEB)
This paper presents the application of artificial neural networks to adiabatic flame temperature prediction of hydrocarbon fuels. The investigation was conducted over a wide range of operating conditions in terms of fuel composition, pressure and temperature of reactants, fuel-air equivalence ratio and fuel vapour fraction. Several neural network models for predicting the flame temperature for different applicable fuel ranges were built and examined. The proper preparation of network training data and the appropriate choice of network parameters for achieving better prediction accuracy are discussed. The neural network prediction results were compared with those calculated by a thermodynamic and chemical equilibrium-based computer code - the NASA program CET89. It was shown that trained neural network models can provide the adiabatic flame temperature prediction with a good level of accuracy over a wide ...
1999-03-01
Assessment of generation temperatures of crude oils
Energy Technology Data Exchange (ETDEWEB)
Biological marker maturity parameters were used to estimate the minimum HC generation temperatures of crude oils from Eastern Hungary. More than 50 oils and oil shows were analysed. Molecular- and homologous-ratios of biological marker compounds (triterpanes, steranes, mono- and triaromatic steroid hydrocarbons) were used as maturation parameters. The oils have at least five maturity stages, i.e. they have been generated under different thermal conditions. The highest reservoir temperature in each group was chosen as the best estimate of the groups' temperature just below the generation temperature, i.e. reservoirs of the group might be expected to be at shallower depths (lower temperatures) than those of the generation zone due to vertical migration into pools. For each maturation level, a threshold temperature ...
2000-07-01
The result of Alanine/ESR dosimetry at Wolsung unit 1
International Nuclear Information System (INIS)
It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate dose, two ...
2008-10-01
Studies on improvement of heat transfer characteristics in high temperature heat exchangers, (1)
International Nuclear Information System (INIS)
Reported in this paper are the theoretical and experimental studies, with regard to the effects of radiation between walls, conducted for the improvement of heat transfer characteristics of the circular duct in high temperature heat exchangers that operate through the medium of non-radiating gases at around 1,000"0C. To study the fundamental performance of the heat transfer augmentation, the experiment was carried out using a double tube at temperatures up to 900"0C. The outer tube in a double tube was selectively heated so as to give a uniform heat flux selected of 6.5 x 10"3 and 4.6 x 10"4 kcal/m"2.h, while the inner tube was used as a radiating surface to impart the radiation heat transmitted from the outer tube. Selectively preheated air was caused to flow in an annular passage at an inlet temperature selected within 100"0C to 400"0C and with the Reynolds number of 2.9 x 10"3 to 3.5 x 10"4. The heat ...
1978-01-01
Isotope exchange reaction between tritiated water and hydrogen on SiC
Energy Technology Data Exchange (ETDEWEB)
SiC has been considered as a primary candidate material for a first wall component in future fusion reactor because it has been claimed that SiC has excellent high-temperature properties, good chemical stability and low activation. However, the behavior of tritium on SiC has not been discussed yet. In this study, tritium trapping capacity on the surface of SiC was experimentally obtained at the temperature range of 25-800 deg. C in consideration of tritium trapping to the experimental system. The capacity, which was independent of the water vapor pressure in the gas phase and the temperature, was determined as about 10{sup 6} Bq/cm{sup 2}. The isotope exchange reaction rate between tritiated water in a gas phase and hydrogen on the surface was quantified at the temperature of 25, 500 and 700 deg. C in consideration of the behavior of tritium trapping at change of experimental ...
2003-11-15
Isotope exchange reaction between tritiated water and hydrogen on SiC
International Nuclear Information System (INIS)
SiC has been considered as a primary candidate material for a first wall component in future fusion reactor because it has been claimed that SiC has excellent high-temperature properties, good chemical stability and low activation. However, the behavior of tritium on SiC has not been discussed yet. In this study, tritium trapping capacity on the surface of SiC was experimentally obtained at the temperature range of 25-800 deg. C in consideration of tritium trapping to the experimental system. The capacity, which was independent of the water vapor pressure in the gas phase and the temperature, was determined as about 10"6 Bq/cm"2. The isotope exchange reaction rate between tritiated water in a gas phase and hydrogen on the surface was quantified at the temperature of 25, 500 and 700 deg. C in consideration of the behavior of tritium trapping at change of experimental condition by the ...
2003-11-15
Energy Technology Data Exchange (ETDEWEB)
In this paper, an approximate curve fitting method for photovoltaic modules is presented. The operation is based on solving a simple solar cell electrical model by a microcontroller in real time. Only four voltage and current coordinates are needed to obtain the solar module parameters and set its operation at maximum power in any conditions of illumination and temperature. Despite its simplicity, this method is suitable for low cost real time applications, as control loop reference generator in photovoltaic maximum power point circuits. The theory that supports the estimator together with simulations and experimental results are presented. (author)
2007-05-15
Electron and phonon properties of 25 A-15 superconductors obtained from heat capacity measurements
International Nuclear Information System (INIS)
We review 25 specific heat measurements performed in Geneva on binary and pseudo-binary A-15 compounds. The rather extended temperature range allows us to make reliable estimates of several moments of the phonon spectrum which are required in the theory of superconductivity. The Tsub(c) expression of Allen and Dynes can then be used consistently to estimate the microscopic parameters lambda, eta, Nsub(bs) (Esub(F)), etc. The broad range of values reviewed permits to establish significant correlations between the parameters in stoichiometric and ordered compounds. (orig.).
Development of a non-premix radiant burner. Final report
Energy Technology Data Exchange (ETDEWEB)
The objective of the first project period is to: make a study into materials suitable for the non-premix radiant burners (NPRB); choose the materials for the construction; make proposals for the design of the NPRB; test the different proposals with a CFD-model. In pursuit of finding a suitable material it is necessary first to estimate the maximum temperature that will occur in the burner. It has been estimated that the maximum adiabatic flame temperature will be about 2400-2500 K. The maximum temperature in the burner will of course never reach this level. A more realistic temperature was estimated to 2100-2300 K. The final choice was made after having contacted some of the leading producers. It was possible to find one producer that could produce burners of one of the suggested materials, zirconia. Several construction ideas for the NPRB ...
1998-12-31
Energy Technology Data Exchange (ETDEWEB)
The paper studied a possibility of estimating characteristics of coal liquefaction residue from liquefaction conditions in the case of fixing coal kind in the NEDOL process coal liquefaction PSU. Wyoming coal was used for the study, and the already proposed simplified liquefaction reaction models were used. Among material balances explained by the models, those of asphaltene, preasphaltene, THF insoluble matters are concerned with residue composition. Ash content is separately calculated from ash balance. Reaction velocity constants of simplified liquefaction reaction models which influence the residue composition were obtained by the multiple regression method from experimental results in the past. The estimation expression of residue viscosity was introduced from residue ash/composition. When the residue composition is estimated by the model from liquefaction conditions, and the residue viscosity is obtained using it, the ...
1996-10-28
International Nuclear Information System (INIS)
Natural convection flow is established in KMRR (Korea Multi-Purpose Research Reactor) reflector tank at the loss of reflector circulator. To simulate the reflector tank natural convection flow with high temperatures at the inner shell and bottom plate due to nuclear heating, experimental and numerical studies in an open cavity with 'L' type heated wall made by the combination of a vertical and horizontal plate were performed. It was confirmed through these studies that the heat transfer rates were highest at the lower region of the vertical plate and the inlet region of horizontal plate and comparatively high at the middle portion of both plates. The heat transfer rate distribution of this trend shows a desirable trend for the effective natural convection cooling of KMRR reflector tank. It was also confirmed that the average Nusselts numbers at the 'L' type heated wall were lower than those obtained from the existing ...
1991-10-26
Turbulent heat transfer augmentation and friction in periodic fully developed channel flows
Energy Technology Data Exchange (ETDEWEB)
Measurements are presented of the distribution of average friction factors (f) as well as local and average ({ovr Nu}) heat transfer coefficients for fully developed channel flows with two rib-roughened opposite walls. The temperature measurements were made by using both a laser holographic interferometer and thermocouples. In addition, the reattachment length was determined by flow visualization. The Reynolds number (Re) was varied from 5.0 {times} 10{sup 3} to 5.4 {times} 10{sup 4}; the rib pitch-to-height ratios (Pi/H) were 10, 15, 20; and the rib height-to-hydraulic diameter ratios (H/De) were 0.063, 0.081, and 0.106. The detailed results allowed the peaks of heat transfer augmentation and the regions susceptible to hot spots to be located and allowed the relative contribution of the rib surface and the channel wall to the heat transfer augmentation to be determined. Moreover, relative to a smooth duct, the enhancement ...
1992-02-01
Spectral dependence of ultrasonic attenuation for hydrided Zr-2.5%Nb Alloy
International Nuclear Information System (INIS)
The cold-worked Zr-2.5%Nb alloy is used as material for the pressure tubes in CANDU nuclear reactors. During the service life in reactor, diffusion of hydrogen and/or deuterium in the pressure tubes wall occur. Below a certain temperature, a stable hydride of zirconium is formed, as a brittle phase which can lead to catastrophic failures. For this reason, it is very important to be able to investigate the hydrogen effect on the micro structural properties of zirconium alloys. In the present paper a non-destructive testing technique is used, known as ultrasonic spectral analysis. When an ultrasonic signal traverses a medium, the frequency components associated with the input signal are altered. By frequency analysing the reflected signals, it is possible to study and compare the material properties. The two major parameters measured in ultrasonic spectroscopy are the attenuation and the velocity of the waves. Attenuation is determined by the ...
2009-10-12
Simulation of electromechanical and thermomechanical loads on first wall mock-ups
International Nuclear Information System (INIS)
In order to study the boundary conditions for the occurrence of ratcheting, a testing rig was erected. In this rig, small-scale mock-ups of the first wall were tested under mechanical conditions similar to those expected during disruptions. These mock-ups were made of stainless steel AISI 316. They were heated on the surface and water cooled from inside. Disruption forces were simulated by a high-speed hydraulic bending system by impact loads. The mock-ups were heated by a high-frequency generator and cooled by water through two cooling channels.In addition to the experimental work, simplified analytical analysis and numerical calculations were carried out using the finite element program ABAQUS. In these calculations, the temperature and stress fields in the mock-ups were investigated and the influence of the different constitutive equations was studied.The experimental results confirm the ratcheting behaviour predicted by the calculations. It ...
Second law analysis of compressible flow through a diffuser subjected to constant heat flux at wall
International Nuclear Information System (INIS)
Entropy generation is equivalent to destruction of available work (exergy). The useful energy is destroyed due to the intrinsic irreversibility associated within thermodynamic systems. Exergy analysis can be used as an effective basis for the development and improvement of systems design not only in the overall perspective but also in the individual component level. Second law analysis provides a useful tool to identify the irreversibility in any thermal system. This study presents the investigation of local and total entropy generation in compressible flow through a diffuser. Air is used as the fluid. Uniform heat flux boundary condition is applied at the wall. Two dimensional solution of velocity and temperature fields are obtained using the CFD code FLUENT. Distribution of entropy generation rate is investigated throughout the volume of the fluid as it flows through the diffuser. Regions of high entropy generation in the diffuser have been ...
2010-12-01
Cracking of Alloy 800 tubing in superheated steam in a solar receiver
Energy Technology Data Exchange (ETDEWEB)
The solar central receiver at the Barstow Pilot Plant is a once-through steam boiler consisting of vertical arrays of Alloy 800 tubes. Water/steam leaks associated with tube bends near the receiver outlet were observed after 16 service months. The leaks resulted from through-wall cracks localized in the crown of tube bends operating in the temperature range from 550 to 650/sup 0/C. Initiation occurred on the ID (steam side) of the tube and propagated transgranular through the tube wall. Cracking was axial and circumferential; in general, the circumferential cracks were more severe than the axial cracks. Thick oxide layers showed on the ID of the receiver tubes; a 25-..mu..m thick oxide layer had formed on tubing which operated at 650/sup 0/C. In addition, an enhanced oxidation layer was observed along a narrow band in the crown of the tube. This band was up to five times thicker than the oxide elsewhere in the tube. All ...
1985-10-01
Structure of Mesita del Buey at TA-54, Los Alamos National Laboratory, New Mexico
Energy Technology Data Exchange (ETDEWEB)
The geological structure of Mesita del Buey at Technical Area 54 (TA-54) was examined using precise surveying of the contact between units 1v and 2 of the Tshirege Member of the Bandelier Tuff at 3.5 km along the north wall of Pajarito Canyon and 0.6 km along the north wall of a tributary to Canada del Buey. Estimated structure contours on this contact indicate typical strikes of N40E to N70E along this part of Mesita del Buey, although the apparent strike of the tuff is E-W at the western part of the survey. Typical dips are 1.0{degree} to 2.0{degree} to the east or southeast, with an estimated maximum dip of 3.2{degree} near the west end of Material Disposal Area G. Thirty seven faults with vertical displacements of 5 to 65 cm were observed in outcrop along the Pajarito Canyon traverse, and, due to the incomplete exposure of the unit 1v-unit 2 contact, many more faults of this magnitude undoubtedly ...
1998-04-23
Energy Technology Data Exchange (ETDEWEB)
Global climate policy initiatives are now being proposed to compensate tropical forest nations for reducing carbon emissions from deforestation and forest degradation (REDD). These proposals have the potential to include developing countries more actively in international greenhouse gas mitigation and to address a substantial share of the world's emissions which come from tropical deforestation. For such a policy to be viable it must have a credible benchmark against which emissions reduction can be calculated. This benchmark, sometimes termed a baseline or reference emissions scenario, can be based directly on historical emissions or can use historical emissions as input for business as usual projections. Here, we review existing data and methods that could be used to measure historical deforestation and forest degradation reference scenarios including FAO (Food and Agricultural Organization of the United Nations) national statistics and various remote sensing sources. The ...
2008-04-15
International Nuclear Information System (INIS)
Global climate policy initiatives are now being proposed to compensate tropical forest nations for reducing carbon emissions from deforestation and forest degradation (REDD). These proposals have the potential to include developing countries more actively in international greenhouse gas mitigation and to address a substantial share of the world's emissions which come from tropical deforestation. For such a policy to be viable it must have a credible benchmark against which emissions reduction can be calculated. This benchmark, sometimes termed a baseline or reference emissions scenario, can be based directly on historical emissions or can use historical emissions as input for business as usual projections. Here, we review existing data and methods that could be used to measure historical deforestation and forest degradation reference scenarios including FAO (Food and Agricultural Organization of the United Nations) national statistics and various remote sensing sources. The freely ...
International Nuclear Information System (INIS)
Piping systems transporting high-pressure fluid will release a large amount of energy, leading to whipping of the broken pipe as well as impingement of the ejecting fluids on adjacent structures if they fracture unstably. Postulation of such an event in design of piping systems in nuclear power plants often requires various counter measures such as installation of pipe whip restraints or jet impingement shields to prevent such damage. One of the approaches to justify exclusion of unstable fracture from the design conditions is leak-before-break (LBB) analysis. In order to demonstrate LBB behavior, it is necessary to prove that in the presence of a part-through wall flaw in the pipe, this flaw will not grow through the wall under fatigue loading and is stable (level 2 LBB) and that the leak of fluid through the penetration is detected by leak detection systems before unstable fracture occurs (level 3 LBB). If this can be demonstrated in plant ...
2006-11-01
This paper discusses a new control strategy for photovoltaic power generation systems with consideration of dynamic characteristics of the photovoltaic cells. The controller estimates internal currents of an equivalent circuit for the cells. This estimated, or the virtual current and the actual voltage of the cells are fed to a conventional Maximum-Power-Point-Tracking (MPPT) controller. Consequently, this MPPT controller still tracks the optimum point even though it is so designed that the seeking speed of the operating point is extremely high. This system may suit for applications, which are installed in rapidly changeable insolation and temperature-conditions e.g. automobiles, trains, and airplanes. The proposed method is verified by experiment with a combination of this estimating function and the modified Boehringer's MPPT algorithm.
2004-01-01
Ozone removal by green building materials
Energy Technology Data Exchange (ETDEWEB)
Interest in finding out passive ways to keep the variation in the indoor climate within the comfort zone is gaining in popularity. One possible solution is the use of the moisture-buffering property of materials. In this study, the effects of the ventilation system and moisture-buffering properties of the building fabric on the stability of the indoor temperature and humidity are analysed by means of long-term field measurements. Indoor climate measurements were carried out in 170 detached houses (248 rooms). Temperature and relative humidity were measured continuously in bedrooms and living rooms at one-hour intervals over a one-year period. In general, it may be concluded that in this study, the ventilation had a greater effect on the indoor climate than the properties of the building fabric. The dampening effect of hygroscopic materials was remarkably less in the field measurements than it was in simulations in different studies. This ...
2009-08-15
Energy Technology Data Exchange (ETDEWEB)
US Department of Energy (DOE) Order 5820.2A (DOE, 1988) requires performance assessments on all new and existing low-level radioactive waste (LLW) disposal sites. An integral part of performance assessment is estimating the fluxes of radioactive gases such as radon-220 and radon-222. Data needs pointed out by mathematical models drive site characterization. They provide a logical means of performing the required flux estimations. Thorium-230 waste, consisting largely of thorium hydroxide and thorium oxides, has been approved for disposal in shallow trenches and pits at the LLW Radioactive Waste Management Site in Area 5 of the Nevada Test Site. A sophisticated gas transport model, CASCADR8 (Lindstrom et al., 1992b), was used to simulate the transport and fate of radon-222 from its source of origin, nine feet below a closure cap of native soil, through the dry alluvial earth, to its point of release into the atmosphere. CASCADR8 is an M-chain ...
1993-12-01
Radius of thawing around an injection well and time of complete freezeback
An approximate method of calculating the radius of thawing around an injection well is presented. The method is based on the assumption that for a cylindrical system the position of the phase interface in the Stefan problem can be approximated through two functions: one function determines the position of the melting-temperature isotherm in the problem without phase transitions and the second function does not depend on time. The adjusted heating time concept was used to describe the first function. The second function is a known analytical relationship and is expressed in terms of ice content, thermal properties of thawed/frozen formations, formation temperature and the temperature of the injected fluid. Simple approximate formulae are suggested to estimate the duration of the freezeback period. To verify the proposed formulae, the results of numerical solutions were used. An example which shows that ...
2006-06-01
Energy Technology Data Exchange (ETDEWEB)
Hydrate addition at low temperature (or the HALT process) is a retrofit option for moderate SO/sub 2/ removal efficiency in coal burning utility plants. This dry FGD process involves injecting calcium based dry hydrate particles into flue gas ducting downstream of the air preheater where the flue gas temperature is typically in the range of 280-325/degree/F. This report is comprised of the conceptual scaleup design of the HALT process to a 180 MW and a 500 MW coal fired utility station followed by detailed capital and operating cost estimates. A cost sensitivity analysis of major process variables for the 500 MW unit is also included. 1 fig.
1988-12-01
Swimming endurance of whiteleg shrimp, Litopenaeus vannamei exposed to various temperatures (15, 20, and 25 degrees C) and salinities (15, 32, and 40 per thousand) was determined in a swimming channel against one of five flow velocities (5.41, 6.78, 8.21, 10.11, and 11.47 cm s(-1)) for up to 9000 s. No shrimp swam the full 9000 s throughout the experiment. The swimming endurance decreased as swimming speed was increased at any of the temperatures and salinities tested and was significantly affected by temperature and salinity (Ppower model (nu x t(b) = a) showed a better fit to the relationship between swimming endurance (t, in s) and swimming speed (nu, in cm s(-1)) at any of the temperatures and salinities tested. The swimming ability index (SAI), defined as SAI = integral(0)(9000) vdt x 10(-4) (cm), was found to be temperature- and salinity-dependent in L. vannamei. The optimum ...
2006-11-29
Non-equilibrium modelling of an oxygen-plasma cutting torch
International Nuclear Information System (INIS)
A two-temperature, axi-symmetric, chemical non-equilibrium model has been developed for an oxygen-plasma cutting torch in two dimensions to obtain distributions of different plasma quantities inside the torch. Apart from mass, momentum and potential conservation equations, separate energy balance equations are considered for electrons and heavy particles. The ?-? model has been used to account for turbulence. Non-equilibrium properties required for fluid dynamic simulations are obtained from a non-equilibrium property code that includes chemical non-equilibrium. The results show distributions of temperature, velocity, pressure, potential, current density and different species densities inside the plasma torch for an arc current of 200 A. Plasma pressure inside the torch varies from several atmospheres to near-atmospheric pressure. It has been observed that the electron and the heavy particle temperatures differ less near ...
2007-04-07
Natural convection cooling of a close-packed array of AGR fuel pins surrounded by graphite debris
International Nuclear Information System (INIS)
Certain postulated faults during refuelling of AGRs may give rise to compacted fuel and graphite sleeve debris. This debris must be maintained below some safe limiting temperature. As part of a programme to assess the benefits of natural convection in cooling such debris in a region experiencing no forced cooling, a simple geometry incorporating typical debris has been studied both experimentally and by prediction. The experiment comprised an array of electrically heated fuel rods mounted co-axially in a closed cylindrical vessel and surrounded by fragments of graphite. The vessel was cooled on its cylindrical surface, the ends being insulated. Rods and vessel wall were thermocoupled. Tests covered a range of temperature and pressures in both CO_2 and N_2. Significant natural convection heat removal was demonstrated, particularly at high pressure. Predictions utilising the PHOENICS code agreed well with measured ...
Energy Technology Data Exchange (ETDEWEB)
This work presents comparative results of a numerical investigation of four possible models for the prediction of thermal performance of fixed bed storage units and their thermal design. These models includes Schumann's model, the radial dispersion model, a model that include both axial heat conduction in the fluid phase and admits thermal gradient in the solids particles and finally a two dimensional single phase model. For each of these models a computer code was written and tested to evaluate the computing time of same data and analyze any other computational problems. The tests of thermal performance included particle size, porosity, particle material, flow rate, inlet temperature and heat losses form tank walls and extremities. Dynamics behaviour of the storage units due to transient variation in either flow rate or inlet temperature was also investigated. The results presented include ...
1991-07-01
A procedure for temperature-stress fields calculation of WWER-1000 primary circuit in PTS event
International Nuclear Information System (INIS)
The paper presents the procedure of an investigation of WWER-1000 primary circuit temperature-stress field by the use of thermohydraulic computation data for a pressurized thermal shock event ''Core overcooling''. The procedure is based on a model of the plane stress state with ideal contact between wall and medium for the calculation. The computation data are calculated on the base of WWER-1000 thermohydraulic model by the RELAP5/MOD3 codes. This model was developed jointly by the Bulgarian and BNL/USA staff to provide an analytical tool for performing safety analysis. As a result of calculations by codes the computation data for temperature field law (linear laws of a few distinguished parts) and pressure of coolant at points on inner surface of WWER-1000 primary circuit equipment are received. Such calculations can be used as a base for determination of all-important load-carrying sections of the primary circuit pipes ...
1997-05-05
Energy Technology Data Exchange (ETDEWEB)
The authors report a two-temperature RF bias stress test on nominal 1.2 W 7.5 GHz GaAs/AlGaAs HBT unit cell amplifiers. MTTF`s of 2020 and 1340 hours were obtained at Tj = 218{degrees}C and 245{degrees}C, respectively, under nominal input bias. An activation energy of 0.42 eV is estimated, consistent with published results for similar devices under DC bias stress.
1995-12-31
Metallic behavior of Pd atomic clusters
Energy Technology Data Exchange (ETDEWEB)
We report a study of the nonmetal-metal transition of free-standing Pd{sub N} clusters (2{<=}N{<=}21) carried out through two different theoretical approaches that are extensively employed in electronic structure calculations: a semi-empirical tight-binding (TB) model and an ab initio DFT pseudopotential model. The calculated critical size for the metallic transition decreases rapidly with the temperature and an oscillatory dependence with the cluster size is obtained, particularly in the DFT approach. The TB model describes the metallic behavior for cluster sizes beyond N{approx}12 well. Our obtained critical size at room temperature is of the order of the experimental estimation.
2007-09-12
Heating of magneto-rheological fluid dampers: a theoretical study
This paper focuses on a theoretical model that predicts the temperature increase of Magneto-rheological (MR) fluid dampers experiencing a sinusoidal input motion. A theoretical model is developed to estimate the temperature rise based on the non-linear behavior of the MR fluid damper. This model is solved numerically, and the numerical solution is compared with a known linear solution and experimental result in order to validate the accuracy of the model. Also, a non-dimensional form of the governing equations are developed to examine the key parameters. The non-dimensional terms show the effect of external and internal parameters on the trends of heat dissipation as well as heat generation within the MR fluid damper.
1999-05-01
Heat generation of magneto-rheological fluid dampers
This study presents a theoretical analysis of heat generation and dissipation of field-controllable magneto-rheological fluid (MRF) shock absorbers. Since MRF dampers are energy- dissipating devices, the issues of heat generation and dissipation are important in predicting their performance. A theoretical model is developed based on Bingham plastic model to estimate temperature history of the MRF dampers. The governing equation includes the MRF viscosity as a function of the temperature. The numerical solutions are compared with experimental results in order to validate the accuracy of the model, and excellent agreements are obtained.
2000-04-01
Numerical study of the impingement of a supersonic, axisymmetric jet on a flat plate
International Nuclear Information System (INIS)
A numerical method for studying the flow field of an under-expanded axis-symmetric jet created by a converging-diverging nozzle and impinging on a flat plate is presented. The calculation domain of interest is a region that contains all the features of the jet that leaves the nozzle and impinges onto the plate. Axial symmetry of the domain allows a reduced 2-dimensional model to be used. FLUENT software is utilized to solve the continuity, momentum and energy equations using a coupled implicit scheme. The ideal-gas law is used to determine the gas density along with a k-#epsilon# turbulence model with a special modification to account for compressibility effects. In addition, the temperature dependency of viscosity has been taken into consideration. A number of different modeling techniques are investigated including different approximations to account for the flow inside the nozzle. Performance of non-equilibrium wall functions for ...
Subcellular Localization of Expansin mRNA in Xylem Cells12
UK PubMed Central (United Kingdom)
Terminal differentiation of many vascular cells involves cell wall changes. Cells first elongate their primary wall, then lay down a lignified secondary wall, which is often followed by digestion of...Full Text Available
2000-06-01
System for cooling primary gas coolers using return water stabilized by means of ammonium sulfate
Energy Technology Data Exchange (ETDEWEB)
Discusses scaling of closed systems for cooling coal gas from black coal coking. Scaling rate and factors that influence scaling are analyzed. Physical and chemical properties of scale buildup on the inner walls of pipe cooling systems are evaluated. Water pH value and its effects on scaling and solubility of chemical compounds that form scale are discussed. Use of ammonium sulfate for scale control is analyzed. Consumption rate of ammonium sulfate depends on ambient temperature, water pH value and chloride content in return water. Formulae for calculating optimum content of ammonium sulfates for scale control are derived. 3 refs.
1989-08-01
Spray, combustion, and heat transfer studies in a Ricardo hydra direct-injection diesel engine
Energy Technology Data Exchange (ETDEWEB)
The spray and combustion development in a single-cylinder, direct-injection diesel engine equipped with optical access was examined using a number of complementary techniques. A laser imaging system, based around a pulsed copper-vapour laser synchronised to an intensified CCD camera, was used to obtain images of the four fuel sprays prior to combustion, and to determine the tip penetration of each spray as a function of crankangle. The surface heat flux to the wall of the piston bowl was measured by placing a fast-response thermocouple at the impingement point of one of the sprays, and a two-colour imaging system was used to obtain digital images of the flame temperature and equivalent soot distribution in the cylinder. (author)
1996-12-31
British Library Electronic Table of Contents (United Kingdom)
Although the outer surface of single-walled carbon nanotubes (atomically thin cylinders of carbon) can be involved in a wide range of chemical reactions, it is generally thought that the interior surface of nanotubes is unreactive. In this study, we show that in the presence of catalytically active atoms of rhenium inserted into nanotubes, the nanotube sidewall can be engaged in chemical reactions from the inside. Aberration-corrected high-resolution transmission electron microscopy operated at 80?keV allows visualization of the formation of nanometre-sized hollow protrusions on the nanotube sidewall at the atomic level in real time at ambient temperature. Our direct observations and theoretical modelling demonstrate that the nanoprotrusions are formed in three stages: (i) metal-assisted d...
2011-01-01
Peel-off case failure in thermal explosions observed by the deflagration cylinder test
British Library Electronic Table of Contents (United Kingdom)
We have discovered a previously unidentified thermal explosion mode using the Los Alamos deflagration cylinder test (DFCT). The DFCT is a "pipe bomb"-style test similar to the detonation cylinder test (DTCT), which has been used for many years to calibrate detonation product equations of state. The shot is heated in an oven to a uniform test temperature. The pre-heated high explosive (HE) is triggered by a hot wire initiator on one end. The tube is back-illuminated by a bright light source, and its combustion-driven deformation and subsequent break-up are observed by a high-speed framing camera. Like the DTCT, the DFCT tube wall motion provides the primary diagnostic. A variety of reactive responses are possible, including quasi-steady deflagration and deflagration-to-detonation transition...
2009-01-01
British Library Electronic Table of Contents (United Kingdom)
Crustal xenoliths (pyroxenites and plagioclase + quartz + pyroxene lithologies) from the Quaternary Big Pine volcanic field on the eastern flank of the Sierra Nevada Batholith in California (USA) represent the products of metasomatic reaction between the margins of a Cretaceous granodioritic pluton and Paleozoic marbles, possibly at mid-crustal depths based on the equilibration temperatures recorded by Ti-in-quartz geothermometry. This interpretation is based on the presence of plagioclase showing relict plutonic textures, pyroxenite characterized by nearly pure diopside clinopyroxene, recrystallized plagioclase with anomalously high anorthite content, textures indicating replacement of plagioclase by clinopyroxene (and vice versa), `ghost' plagioclase rare earth element signatures in some...
2011-01-01
Non-catalytic and catalytic wet air oxidation of pharmaceuticals in ultra-pure and natural waters
British Library Electronic Table of Contents (United Kingdom)
A wet air oxidation (WAO) process was applied to four selected pharmaceuticals (metoprolol, naproxen, amoxicillin, and phenacetin) individually dissolved in ultra-pure water, varying the temperature and oxygen pressure. Due to the moderate (amoxicillin) or low (metoprolol, naproxen, and phenacetin) efficiency found in the oxidation of these pollutants, a catalytic wet air oxidation (CWAO) process was then tested using a platinum catalyst supported on multi-walled carbon nanotubes (CNT). In this CWAO process, the pharmaceuticals were dissolved together in ultra-pure water and in four natural water matrices-a reservoir water, a groundwater, and two waters from different municipal wastewater treatment plants. On the basis of the measurements of their removals, a discussion is given of the inf...
2011-01-01
Materials and Components Technology Division research summary, 1992
Energy Technology Data Exchange (ETDEWEB)
The Materials and Components Technology Division (MCT) provides a research and development capability for the design, fabrication, and testing of high-reliability materials, components, and instrumentation. Current divisional programs related to nuclear energy support the development of the Integral Fast Reactor (IFR): life extension and accident analyses for light water reactors (LWRs); fuels development for research and test reactors; fusion reactor first-wall and blanket technology; and safe shipment of hazardous materials. MCT Conservation and Renewables programs include major efforts in high-temperature superconductivity, tribology, nondestructive evaluation (NDE), and thermal sciences. Fossil Energy Programs in MCT include materials development, NDE technology, and Instrumentation design. The division also has a complementary instrumentation effort in support of Arms Control Technology. Individual abstracts have been prepared for the ...
1992-11-01
Limits of the simulation of a nuclear fuel pin by an electrically heated rod
Energy Technology Data Exchange (ETDEWEB)
The utilization of electrically heated rods for the simulation of nuclear fuel pins represents a generally adopted method by the nuclear industry to study thermalhydraulic problems. Usually its is necessary to determine the time variation of the electric linear power to simulate a given nuclear power transient in order to yield the same temperature and heat flux conditions in the surface of the electrical heater that would be observed in the nuclear fuel pin. The present work analyzes the limits of the usually adopted simulation methods and shows a manner to obtain the required electrical linear power that reduces oscillations and yields accurate results for the thermal conditions of the rod surface wall. (author). 5 refs, 5 figs, 1 tab.
1992-12-31
Limits of the simulation of a nuclear fuel pin by an electrically heated rod
International Nuclear Information System (INIS)
The utilization of electrically heated rods for the simulation of a nuclear fuel pins represents a generally adopted method by the nuclear industry to study thermalhydraulic problems. Usually, it is necessary to determine the time variation of the electric linear power to simulate a given nuclear power transient in order to yield the same temperature and heat flux conditions in the surface of the electrical heater that would be observed in the nuclear fuel pin. The present work analyses the limits of the usually adopted simulation methods and shows a manner to obtain the required electrical linear power that reduces oscillations and yields accurate results for the thermal conditions of the rod surface wall. (author) 5 refs., 5 figs., 1 tab.
1992-12-01
Infrared monitoring of the Doublet III beam armor plate
Energy Technology Data Exchange (ETDEWEB)
An 80 keV, 3.6 MW neutral beam injection system has recently been installed on Doublet III, and the installation of a second system is scheduled within several months. Armor plate consisting of /approximately equals/100 graphite tiles (10 cm x 10 cm) coated with TiC has been plated over portions of the inner vacuum wall lying in the line of sight of the ion sources. In order to monitor the condition of the armor plate an infrared camera and a set of optical pyrometers have been installed alongside the beamline and view the armor plate through a CaF/sub 2/ window. The pyrometers measure the temperature of the armor plate associated with the maximum of the intensity distribution of each ion source.
1981-01-01
Helium-cooling in fusion power plants
Energy Technology Data Exchange (ETDEWEB)
This paper reviews different helium-cooled first wall and blanket designs; and compares the selection of structural materials. The authors found that the solid breeder, SiC-composite material option generates the lowest amount of induced radioactivity and afterheat and has the highest temperature capability. When combined with the direct cycle gas turbine system, it has the potential to be the most economical fusion system and can compete with advanced fission reactors. When compared to martensitic steel and V-alloy, SiC-composite is the least developed of these three structural materials, a focused development effort will be needed. Fundamental research has begun in addressing the issues of optimized composite materials, irradiation effects, leak tightness and low activation braze materials. Development of helium-cooled high heat flux components and further development of the direct cycle gas turbine system will also be needed.
1994-11-01
Development of sealing insulator for electric penetration assemblies
International Nuclear Information System (INIS)
Electrical penetration assemblies mounted on the containment wall are used to carry electrical power and signals from the equipment inside this containment (e.g. recirculation pumps, control rod position indications etc.) Todays BWR nuclear power plants apply epoxy resin sealed electric penetration. Contrariwise, the epoxy resin (organic sealant) was replaced with sodium barium glass (inorganic) by way of trial in search for a quality sealant. The glass sealant has been proved to have high temperature airtightness at 300 degC above from an evaluation test involving full-scale model parts. Environmental tests were conducted continuously as to heat cycle, vibration and LOCA etc. the specimens (module) of five types. They were made certain of conformity to the design requirements for boiling water operation. (author).
Development of a solar thermal storage system suitable for the farmhouse heating in northeast China
Energy Technology Data Exchange (ETDEWEB)
This study reported on the performance of a passive solar radiant floor heating system designed for standard energy-saving farmhouses in northeast China. Weather data in the region was analyzed in terms of solar radiation, temperature, humidity and light levels. The heating characteristics of the building materials such as windows, doors, walls and roofs were also analyzed along with the indoor thermal environment of the farmhouse. The heating load was then calculated along with the size of the thermal storage element and the area of the collector element. The passive solar radiant floor heating system was designed for heating during the winter and cooling in summer. According to the results, the heating characteristics of the system have the potential to improve farming villages environment and the use of renewable energy.
2010-07-01
Comparison of fluid-dynamic modeling of flow with velocity-encoded MR imaging
International Nuclear Information System (INIS)
This paper develops a fluid dynamic model using finite difference methods characterizing flow in phantoms simulating in vivo conditions and to compare those results with velocity encoded MR images. The phantom consisted of 1-inch (2.5-cm) tubing with semicircular insert and fluid with viscosity, T1, and T2 comparable to blood. Numeric solutions to Navier-Stokes equations for this system were obtained using finite difference methods, with velocity input function of zero at walls and parabolic at both ends. In resulting color raster (CR) images, color temperature represented velocity value. In velocity-encoded MR images acquired under the same flow conditions, phase is proportional to average velocity during application of flow-encoding gradients. Because these gradients are applied along one direction per acquisition, magnitude and direction of velocity are obtained.
1990-11-25
Energy Technology Data Exchange (ETDEWEB)
The catalytically stabilised thermal combustion (CST) of lean hydrogen-air mixtures was investigated numerically in a turbulent channel flow configuration using a two-dimensional elliptic model with detailed heterogeneous and homogeneous chemical reactions. Comparison between turbulent and laminar cases having the same incoming mean properties shows that turbulence inhibits homogeneous ignition due to increased heat transport away from the near-wall layer. The peak root-mean-square temperature and species fluctuations are always located outside the extent of the homogeneous reaction zone indicating that thermochemical fluctuations have no significant influence on gaseous combustion. (author) 4 figs., 6 refs.
1999-08-01
International Nuclear Information System (INIS)
About 210 abstracts by Ukrainian and foreign authors submitted to the 11-th International Conference on Plasma Physics and Controlled Fusion and 2-nd Alushta International Workshop on the Role of Electric Fields in Plasma Confinement in Stellarators and Tokamaks have been considered by Conference Program Committee members. All the abstracts have been divided into 9 groups: Magnetic confinement systems (stellarators, tokamaks, alternative conceptions); plasma heating and current drive; ITER and fusion reactor aspects; basic plasma physics; space plasma; plasma dynamics and plasma-wall interaction; plasma electronics; low temperature plasma and plasma technologies; plasma diagnostics.
2006-09-11
Investigation of the frequency-dependence of the MTC noise estimator
International Nuclear Information System (INIS)
The Moderator Temperature Coefficient of reactivity (MTC) was earlier proven to be properly determined via noise analysis when the neutron noise is measured locally and when the radial average of the moderator temperature noise is used. Nevertheless, measurements revealed that the MTC was correctly estimated on a much narrower frequency band (0.6 - 0.7 Hz) than expected (0.1 - 1.0 Hz). The present paper investigates the effect of the feedback on the MTC determination using this new MTC noise estimator (which could explain the deviation at low frequencies, i.e. between 0.1 - 0.5 Hz) and the effect of the detector time constants (which could explain the deviation at high frequencies, i.e. between 0.7 - 1.0 Hz). For that purpose, a coupled neutronic/thermalhydraulic model of the Ringhals-3 PWR is developed in the frequency-domain, based on a radial 2-dimensional heterogeneous representation of the core. ...
2005-09-12
Gravitational Waves from Collapsing Domain Walls
We study the production of gravitational waves from cosmic domain walls created during phase transition in the early universe. We investigate the process of formation and evolution of domain walls by running three dimensional lattice simulations. If we introduce an approximate discrete symmetry, walls become metastable and finally disappear. We calculate the spectrum of gravitational waves produced by collapsing metastable domain walls. Extrapolating the numerical results, we find the signal of gravitational waves produced by domain walls whose energy scale is around 10^10-10^12GeV will be observable in the next generation gravitational wave interferometers.
2010-01-01
Studying the internal structure of granular magnetic nanocomposites by ferromagnetic resonance
British Library Electronic Table of Contents (United Kingdom)
A method for estimating the form of magnetic nanoparticles in composite film structures based on the observation of ferromagnetic resonance phenomenon is offered. Within the model of the effective medium, an explanation is given for experimentally observed concentration and temperature dependences of resonant fields for composite nanosystem (Co45Fe45Z10) f +(Al2O3)100?f .
2010-01-01
Performance estimates for attached-sunspace passive solar heated buildings
Energy Technology Data Exchange (ETDEWEB)
Performance predictions have been made for attached-sunspace types of passively solar heated buildings. The predictions are based on hour-by-hour computer simulations using computer models developed in the framework of PASOLE, the Los Alamos Scientific Laboratory (LASL) passive solar energy simulation program. The models have been validated by detailed comparison with actual hourly temperature measurements taken in attached-sunspace test rooms at LASL.
1980-01-01
Kondo effect in the systems of magnetic trimers on a metal surface
International Nuclear Information System (INIS)
Calculating the local spectral densities at magnetic adatoms, we estimate the variation in the Yosida-Kondo resonance due to the Ruderman-Kittel-Kasuya-Yosida (RKKY) interaction and the direct exchange between adatoms in systems of magnetic trimers on metal surfaces. The results show that the RKKY interaction leads to the gradual variation in Kondo temperature, and the direct exchange can be the origin of the drastic variation. (author)
2010-11-01
Drying of medicinal plants with solar energy utilization
Energy Technology Data Exchange (ETDEWEB)
In the paper, a potential of solar energy for drying of medicinal plants in Polish conditions is estimated and development of solar drying technologies is presented. The results of economic assessment of flat-plate solar collectors applied for drying of medicinal plants on a farm are promising. In some specific conditions, e.g. drying of wild grown medicinal plants in remote areas, even application of photovoltaic modules for driving of a fan of a solar dryer is a profitable option and enables easy control of the drying air temperature.
1997-10-01
Determination of Y, Ba and Cu in superconductor films by x-ray fluorescence analysis
International Nuclear Information System (INIS)
Radionuclide x-ray fluorescence analysis was used for the determination of Y, Ba and Cu in thin high-temperature superconducting films. Atomic emission ICP spectrometry was used to estimate the precision and accuracy of analytical results. Reasonable agreement between both methods was obtained when a polynomial calibration curve was applied. (author) 4 refs.; 4 tabs.
1994-06-01
The Structure of Plant Cell Walls
UK PubMed Central (United Kingdom)
The molecular structure, chemical properties, and biological function of the xyloglucan polysaccharide isolated from cell walls of suspension-cultured sycamore (Acer pseudoplatanus)...Full Text Available
1973-01-01
Constraints on target chamber first wall and target designs that will enable NIF debris shields to survive
1999-01-01
Equivalent dose estimation using a single aliquot of polymineral fine grains
International Nuclear Information System (INIS)
We have tested the suitability of a new single-aliquot regenerative-dose protocol for estimating the equivalent dose (D_e) in polymineral fine grains extracted from colluvia from various sites in Germany. First, we report the behaviour of three OSL signals: (i) blue-stimulated, (ii) infrared-stimulated luminescence, and (iii) blue-stimulated luminescence following infrared (IR) stimulation, using a near-UV (290-380 nm) detection window in each case. For these three signals, there is a significant change in sensitivity with regeneration cycle; this change can be compensated for using the response to a fixed test dose after each natural or regenerated measurement. The source of the three luminescence signals is then investigated using pulse-anneal and elevated-temperature experiments. Fading tests on laboratory-induced signals show that although the IR signals fade by up to 23% in 15 days at 100 deg. C, the post-IR blue signals are stable. The ...
2001-02-01
International Nuclear Information System (INIS)
The Forsmark and the Laxemar investigation areas are examined by the Swedish Nuclear Fuel and Waste Management Co. for a possible construction of a deep repository for nuclear waste. In the case of a future leakage of waste, the radioactive isotopes could end up in the ecosystems above the repository. The fate of the radionuclides and their possible radiological impacts are then highly determined by ecosystem carbon cycling. An important part of the carbon cycling is the soil carbon effluxes, and in the investigation areas soil carbon effluxes have been examined with the closed chamber technique. This paper is divided into two parts. Firstly, there were problems with the equipment measuring the soil carbon dioxide efflux, and the first part is a description of the problem, how it was corrected and its possible causes. The second part is a manual in how to analyse data and calculate annual estimates of soil carbon efflux. The field measurement by the EGM-4 is just ...
2007-01-01
Tunneling spectra of high-temperature superconductors
International Nuclear Information System (INIS)
The frequency dependence of the tunneling spectrum #alpha#"2F (#omega#) is analyzed in terms of electron pairing induced by exchange of acoustic plasmons in addition to the usual phonon-exchange mechanism. Analytic expressions are obtained for the electron self-energy, the tunneling function #alpha#"2F, and the electron pairing coupling lambda which determines the superconducting properties. The resulting theory is applied to recent tunneling data of Nb_3Sn in order to examine the anomalous discrepancies with the phonon density of states found by neutron scattering experiments. The results demonstrate how the high-temperature (T/sub c/ approx. 20 "0K) superconducting properties of A-15 compounds are enhanced by acoustic-plasmon contributions, and thus they reconcile these high transition temperatures with the relatively small values of the phonon part of lambda estimated from several independent experiments.
International Nuclear Information System (INIS)
Molar excess enthalpies and molar excess volumes are reported for the systems H_2O + (C_2H_5)_3N and D_2O + (C_2H_5)_3N at temperatures below and above their lower critical solution temperatures. The molar excess enthalpies are slightly less exothermic for the D_2O system. The molar excess volumes of the H_2O and D_2O systems are within experimental error of one another. Compositions of conjugate solutions estimated from the calorimetric and volumetric measurements agree with those obtained from published liquid-liquid phase diagrams. (Auth.).
1979-01-01
International Nuclear Information System (INIS)
Hydrostatic weighing was used to measure the pre-melt density of crystalline eutectic mixtures of alkaline metal chlorides of the compositions (mole fractions): 0.605 LiCl + 0.395 CsCl, 0.585 LiCl + 0.415 KCl, 0.297 NaCl + 0.246 KCl + 0.457 CsCl, and 0.348 NaCl + 0.652 CsCl with melting points 598, 628, 753, 763 K, respectively, as a function of temperature. In the same temperature ranges, the compressibility and molar volume of eutectics as well as their sudden change upon melting were estimated. Unusual variations of these properties were revealed near the crystal/liquid phase transition, which were related to local disordering of particle configuration
Magnetization of undoped 2-leg S=1/2 spin ladders in La{sub 4}Sr{sub 10}Cu{sub 24}O{sub 41}
Energy Technology Data Exchange (ETDEWEB)
Magnetization data of single crystalline La{sub 4}Sr{sub 10}Cu{sub 24}O{sub 41} are presented. In this compound, doped spin chains and undoped spin ladders are realized. The magnetization, at low temperatures, is governed by the chain subsystem with a finite interchain coupling which leads to short range antiferromagnetic spin correlations. At higher temperatures, the response of the chains can be estimated in terms of a Curie-Weiss law. For the ladders, we apply the low temperature approximation for a S = 1/2 2-leg spin ladder.
2007-09-01
Energy Technology Data Exchange (ETDEWEB)
The liquid/vapor coexistence density, the partial vapor pressure, and the heat of vaporization were calculated using Gibbs ensemble Monte Carlo simulation techniques. Long-range interactions such as charge-charge, charge-dipole, and dipole-dipole were evaluated using Ewald summation techniques. A polarizable potential model was used to describe the water-water interactions (Dang and Chang, J. Chem. Phys. 106, 8149, 1997). The model yields good agreement with the corresponding experimental data in the lower temperature region and moderate agreement in the higher temperature region. The critical temperature and density were estimated to be 565 K and 0.28 g/cm3.
2001-12-01
Estimation of dry rubber content in natural rubber latex by differential scanning calorimetry
British Library Electronic Table of Contents (United Kingdom)
Differential Scanning Calorimetry (DSC) is employed to study the changes in enthalpy of natural rubber latex samples when heated under a controlled temperature program. It is found that the mass normalized areas of the DSC curves between room temperature and 170??C for different latex samples are inversely proportional to the dry rubber content (DRC) of the samples, measured following the weighing and drying method. The changes in total enthalpy of the samples in this temperature range are interpreted as due to the variations in the quantity of water present in the samples. The measurements have been repeated by diluting selected samples with known quantities of water, and it is found that the normalized areas of the DSC curves are directly proportional to the amount of water added to the ...
2010-01-01
Dielectric properties of sols of silver nanoparticles capped by alkyl carboxylate ligands
British Library Electronic Table of Contents (United Kingdom)
Sols of silver nanoparticles in toluene were studied by broadband dielectric spectroscopy (10?3?105 Hz). The frequency dependences of the specific alternating current (ac) conductivity and the complex electric modulus were used to estimate the temperature/frequency intervals of long- and short-range charge transfer occurs, respectively. A considerable increase (by more than 30 ?C) in the Vogel temperature T 0 and the glass transition temperature T g in sols compared with the pure solvent was found. It can be hypothesized that these cooperative effects reflect the initial stage of the superlattice formation. Although the dielectric characteristics of sols are generally controlled by the conductivity relaxation, the dielectric response was observed in the high-frequency range (1?103 Hz) at l...
2011-01-01
Thermal Hydraulics Analysis for the 3MW TRIGA MARK-II Research Reactor Under Transient Condition
International Nuclear Information System (INIS)
Some important thermal hydraulic parameters of the 3 MW TRIGA MARK-II research reactor operating under transient condition were investigated using two computer codes PULTRI and TEMPUL. Major transient parameters, such as, peak power and prompt energy released after pulse, maximum fuel and coolant temperature, surface heat flux, time and radial distribution of temperature within fuel element after pulse, fuel, fuel-cladding gap width variation, etc. were computer and compared with the experimental and operational values as reported in the safety Analysis Report (SAR). It was observed that pulsing of the reactor inserting an excess reactivity of $2.00 shoots the reactor power level to 854.353 MW compared to an experimental value of 852 MW; the maximum fuel temperature corresponding to this peak power was found to be 846.76"o C which is much less than the limiting maximum value of fuel temperature of ...
1985-07-01
Energy Technology Data Exchange (ETDEWEB)
To realise the Dutch objectives of energy saving and emission reductions in the built environment, the use of 'Low Valued Energy' will be necessary in the future. Low Valued Energy is available from residual, ambient heat and renewable sources. Using Low Valued Energy for space heating in commercial and residential buildings requires adjusting the design of the installations, i.e. lowering the design supply temperature of the heating system from 90C to 55C or less. Appropriate heat distribution systems, e.g. floor or wall heating and radiators, have a life cycle of 40 to 50 years. The application (on a large scale in buildings), however, requires an enormous change in the installation and building branch. To enable the application of low temperature sources in the future, the building and installation designs should be based on low temperature distribution systems. Being aware of this ...
2000-06-01
Microclimatic conditions at the external surface of building envelopes
Energy Technology Data Exchange (ETDEWEB)
The project is described, the motivation for the research and the microclimate is defined in relation to both building physics research and applications. Air temperatur, air humidity, solar radiation and air velocity are briefly considered, whilst driving rain and long-wave radiation are described in more detail. Convective heat transfer and surface coefficients are discussed, although they are not microclimatic factors, merely resulting from combinations of such factors. They are included as they are important in relation to transfer of heat and moisture at the surface of the building envelope. Driving rain measurement is the main area of interest, including development of measurement equipment. Long-wave irradiation is measured and compared with empirical formulae from the literature. Window convection heat transfer is another main area of interest. Nocturnal convective heat transfer from a double pane glazing is studied and measurement principles are discussed. ...
1998-12-31
Radiation therapy for Kasabach-Merritt syndrome. Analysis of unfavorable factors in 5 children
Energy Technology Data Exchange (ETDEWEB)
During the past 10 years, five infants with Kasabach-Merritt syndrome (K-M) receiving radiation therapy were reported. We investigated whether radiation therapy for K-M was useful and what the unfavorable factors of K-M were. During the past 10 years, we have treated five infants with K-M. The syndrome occurred at ages ranging from birth to 4 months. The incidence of female to male ratio was 3:2. Among 5 cases, the site of hemangioma was as follows; shoulder, anterior chest wall, lower abdominal wall, face and neck and inguinal site. All 5 cases received medication to control the coagulopathy including prednisone and blood transfusion at first. Because the platelet count and the bleeding tendency did not improve in any case, these cases received radiation therapy. Total dose ranged from 5 to 10 Gy and fraction-size ranged from 0.5 to 1.75 Gy. Irradiation session was 2 or 3 times per week. In 5 cases, 4 cases showed cure of bleeding tendency and ...
1996-03-01
MRI-based N-staging in esophageal cancer
International Nuclear Information System (INIS)
Purpose: For planning the therapeutic strategies and estimating the prognosis in esophageal cancer, N-staging is very important. To date, MRI still is of minor importance as imaging modality of the mediastinum despite promising developments in the past, like ECG-gating or 'averaging' sequences, e.g. LOTA (Long-term averaging), which facilitate mediastinal and thoracic MR-imaging. In a prospective approach, the value of MRI based N-staging was examined with respect to LOTA-sequences. Material and Methods: Within from weeks prior to esophagectomy, standardized MRI of the esophagus was performed in 15 patients (10 squamous-cell-carcinomas and 5 adenocarcinomas) using a 1.5 T whole body scanner. Imaging quality was classified based on depiction of aortic wall or tracheal wall layers. Criteria for malignant infiltration were a diameter of more than 15 mm or a round appearance of a lymph node together with GD-DTPA enhancement. ...
2002-10-01
Energy Technology Data Exchange (ETDEWEB)
A simple method of estimating the amount of lung irradiated in patients with breast cancer would be of use in minimizing lung complications. To determine whether simple measurements taken at the time of simulation can be used to predict the lung volume in the radiation field, we performed CT scans as part of treatment planning in 40 cases undergoing radiotherapy for breast cancer. Parameters measured from simulator films included: (a) the perpendicular distance from the posterior tangential field edge to the posterior part of the anterior chest wall at the center of the field (CLD); (b) the maximum perpendicular distance from the posterior tangential field edge to the posterior part of the anterior chest wall (MLD); and (c) the length of lung (L) as measured at the posterior tangential field edge on the simulator film. CT scans of the chest were performed with the patient in the treatment position with 1 cm slice intervals, ...
1990-01-01
Reduced-aspect-ratio stellarator reactors
Energy Technology Data Exchange (ETDEWEB)
The extent to which the size of a modular stellarator reactor may be reduced is investigated by means of an analytic model of the reactor. The various means employed include varying the blanket/shield thickness, the power output and the wall loading. An optimum design is found, the major radius of which tends to be insensitive to changes in these quantities, although a decrease in the power output leads to a rather smaller decrease in reactor dimensions, as would be expected. Varying the plasma beta at fixed (iota/2..pi..)/sup 2/epsilon or, alternatively, increasing the rotational transform per field period, may, however, allow configurations with fewer field periods to be accessed which have a substantially smaller major radius than the 'standard case' adopted. The magnetics of various configurations required by the model are checked by field line following and the performance claimed is shown to be relatively easily achieved. Costs of two ...
1984-01-01
Pre-transitional disk nature of the AB Aur disk
The disk around AB Aur was imaged and resolved at 24.6\\,$\\mu$m using the Cooled Mid-Infrared Camera and Spectrometer on the 8.2m Subaru Telescope. The gaussian full-width at half-maximum of the source size is estimated to be 90 $\\pm$ 6 AU, indicating that the disk extends further out at 24.6\\,$\\mu$m than at shorter wavelengths. In order to interpret the extended 24.6\\,$\\mu$m image, we consider a disk with a reduced surface density within a boundary radius $R_c$, which is motivated by radio observations that suggest a reduced inner region within about 100 AU from the star. Introducing the surface density reduction factor $f_c$ for the inner disk, we determine that the best match with the observed radial intensity profile at 24.6\\,$\\mu$m is achieved with $R_c$=88 AU and $f_c$=0.01. We suggest that the extended emission at 24.6\\,$\\mu$m is due to the enhanced emission from a wall-like structure at the boundary radius (the inner edge of ...
2010-01-01
INTRINSIC DOSIMETRY: A POTENTIAL NEW TOOL FOR NUCLEAR FORENSICS INVESTIGATIONS
International Nuclear Information System (INIS)
Thermoluminescence (TL) dosimetry was used to measure dose effects on the raw stock material of borosilicate container glass from different geographical locations. Effects were studied at times up to 60 days post-irradiation at doses from 0.15 to 20 Gy. The minimum detectable dose using this technique was estimated to be 0.15 Gy which is roughly equivalent to a 24 hr irradiation 1 cm from a 50 ng source of 60Co. Two peaks were identified in the TL glow curve, a relatively unstable peak around 125 C and a more stable peak around 225 C. Differences in TL glow curve shape and intensity were also observed for the glasses from different geographical origins. We investigate radiation induced defects in glass to further develop the technique of intrinsic dosimetry - the measurement of the total absorbed dose received by the walls of a container holding radioactive material. Intrinsic dosimetry is intended to be used as an interrogation tool to provide ...
2010-07-11
Development of a phoswich detector to detect neutrons in the charged-particle mixed field
Energy Technology Data Exchange (ETDEWEB)
Manned-space missions bring an exposure due to corpuscular radiations of which nature is quite different from what we encounter in the ground environment. In the space environment, many secondaries are produced through interactions of cosmic ray primaries with the spacecraft wall and other surrounding materials. Among this large variety of radiation components in the space, the contribution of neutrons to the radiation exposure of astronauts has remained to be studied. Up to today, efforts to measure neutron dose equivalent have been made using passive detector systems. Considering uncertainties involved in current measurements and estimations of high energy neutrons, and their increasing importance for future manned missions, it is necessary to measure neutron spectrum in the spacecraft under realistic conditions. The neutron spectra have never been measured on board a spacecraft, because the neutron measurement requires to discriminate ...
1997-07-01
Thermal and heat transfer characteristics in a latent heat storage system using lauric acid
Energy Technology Data Exchange (ETDEWEB)
The thermal and heat transfer characteristics of lauric acid during the melting and solidification processes were determined experimentally in a vertical double pipe energy storage system. In this study, three important subjects were addressed. The first one is temperature distributions and temporal temperature variations in the radial and axial distances in the phase change material (PCM) during phase change processes. The second one is the thermal characteristics of the lauric acid, which include total melting and total solidification times, the nature of heat transfer in melted and solidified PCM and the effect of Reynolds and Stefan numbers as inlet heat transfer fluid (HTF) conditions on the phase transition parameters. The final one is to calculate the heat transfer coefficient and the heat flow rate and also discuss the role of Reynolds and Stefan numbers on the heat transfer parameters. The experimental results proved that the PCM melts ...
2002-12-01
Energy Technology Data Exchange (ETDEWEB)
When liquids are confined in nano-scopic dimensions, their properties differ from the corresponding bulk liquid, due to their reduced dimensionality and surface effects. Phase transition temperatures and pressures are often shifted from the bulk values and new phases can appear due to the strong interactions of the molecules with the confining walls. We have studied the structural and dynamical properties of aromatic liquids such as benzene, toluene, and ortho-terphenyl confined in nano-porous materials, MCM-41 and SBA-15, synthesized and characterized in our laboratory. A non-trivial dependence of the glass transition temperature, T{sub g}, on the pore size and surface treatment of nano-porous materials is confirmed and interpreted as resulting from a competition between the fluid-wall and fluid-fluid intermolecular interactions. An increase of T{sub g} is observed for small pore sizes and attractive ...
2006-11-15
Numerical study of natural convection in fully open tilted cavities
Energy Technology Data Exchange (ETDEWEB)
A numerical simulation of two-dimensional laminar natural convection in a fully open tilted square cavity with an isothermally heated back wall is conducted. The remaining two walls of the cavity are adiabatic. Steady-state solutions are presented for Grashof numbers between 10{sup 2} and 10{sup 5} and for tilt angles ranging from {minus}60{degree} to 90{degree} (where 90{degree} represents a cavity with the opening facing down). The fluid properties are assumed to be constant except for the density variation with temperature that gives rise to the buoyancy forces, which is treated by the Boussinesq approximation. The fluid concerned is air with Prandtl number fixed at 0.71. The governing equations are expressed in a normalized primitive variables formulation. Numerical predictions of the velocity and temperature fields are obtained using the finite-volume-based power law (SIMPLER: Semi-Implicit Method ...
1999-09-01
International Nuclear Information System (INIS)
Purpose: The aim of this study was to create, perfect and test a hyperthermia balloon catheter for local treatment of cholangiocarcinoma. The device should induce hyperthermia in tumor tissue by acting locally in the bile duct lumen in contact with the tumor-infiltrated duct wall. In addition, it should exert tissue compression to cause an appreciable reduction in tumor microvasculature flow, thus improving thermal performance. Methods: According to the design specifications, the working temperature range should allow the device to be used for hyperthermia therapy either in combination with radiation and/or chemotherapy(radio/chemo-sensitizing effect at 42-45 deg. C) or alone (induction of coagulation necrosis above 65 deg. C). The balloon serves as an anchoring system during treatment and as a functional element to induce tissue compression. In vitro mechanical evaluation of the pressure/volume relationship, with the balloon inside rigid ...
2003-08-01
Utilization of red mud in the manufacture of ceramic tiles
Energy Technology Data Exchange (ETDEWEB)
Red mud, which is a pollutant residue from the extraction of alumina from bauxite ore, was utilized as an additive to a well blended mixture of three Egyptian clays, feldspar, quartz and grog. This was added in gradual proportions to study its effect on the vitrification properties of fired samples. Samples were moulded under a pressure of 20.7 MPa and fired at temperatures ranging from 950 C to 1100 C for soaking periods up to three hours. Compressive strength was determined as function of percent red mud added and firing temperature. A semi-exponential relation was established between strength and apparent porosity. 50 x 50 mm tiles containing 70% red mud addition and fired at 1100 C for one hour were tested. They were found to match the standards required for glazed wall tiles bodies. Tiles fired at 1100 C for 3 hours were compatible with the standards for glazed floor tiles. (orig.)
2002-07-01
Energy Technology Data Exchange (ETDEWEB)
The ability of residual biomass from the thermotolerant ethanol-producing yeast strain Kluyveromyces marxianus IMB3 to function as a biosorbent for uranium has been examined. It was found that the biomass had an observed maximum biosorption capacity of 120 mg U/g dry weight of biomass. The calculated value for the biosorption maximum, obtained by fitting the data to the Langmuir model was found to be 130 mg U/g dry weight biomass. Maximum biosorption capacities were examined at a number of temperatures and both the observed and calculated values obtained for those capacities increased with increasing temperature. Decreasing the pH of the biosorbate solution resulted in a decrease in uptake capacity. When biosorption reactions were carried out using sea-water as the diluent it was found that the maximum biosorption capacity of the biomass increased significantly. Using transmission electron microscopy, uranium crystals were shown to be ...
1997-06-01
International Nuclear Information System (INIS)
The Gross Decontamination Experiment was conducted on various levels and surfaces of the TMI-2 Reactor Building during February and March 1982 and was designed to investigate the effectiveness of various surface decontamination techniques. The polar crane, D-rings, missile shields, refueling canal, fueling bridge, major equipment, floors and some walls were flushed with low pressure water. Water lances were directed manually and applied water at temperatures between ambient and 60"0C at a flow rate of about 95 liters per minute. In addition, floor surfaces on the 305-ft elevation and floor surfaces and major equipment on the 347-ft elevation were sprayed with high pressure water (floors in the Reactor Building are designated by their elevations above sea level). The water pressure in this case varied between 13.8 and 41.4 mPa and water temperature was at a maximum 60"0C. Certain surfaces were also decontaminated using ...
1984-07-15
Energy Technology Data Exchange (ETDEWEB)
This paper introduces marketability and parts application of PBT in the automotive field. Based on the pursuits in automobiles of weight reduction as measures to improve engine performance, drive performance, and fuel consumption, as well as trends of higher class car orientation, market expansion is expected on engineering resins including PBT. Adoption of PBT/polycarbonate (PC)-based alloy resins is on increase for use in external car parts because of the chemical resistance in PBT, low-temperature shock resistance and appearance of PC. Substitution from Nylon resin in connector application is progressing rapidly because of problems in dimensional stability and compound noise. Air bag sensor parts need to be free of maloperation due to contamination and corrosion in metal contacts caused from gases generated from formed parts, hence development of resins of low gas generation grade is wanted. Valves for exhaust control require ...
1992-06-18
Numerical heat transfer studies of PCMs used in a box-type solar cooker
Energy Technology Data Exchange (ETDEWEB)
Theoretical investigations on the phase change materials (PCMs) used as the heat storage media for box-type solar cookers have been conducted in this study. The selected PCMs are magnesium nitrate hexahydrate, stearic acid, acetamide, acetanilide and erythritol. For a two-dimensional simulation model based on the enthalpy approach, calculations have been made for the melt fraction with conduction only. Different materials such as glass, stainless steel, tin, aluminum mixed, aluminum and copper are used as the heat exchanger container materials in the numerical calculations. The large value of thermal conductivity of heat exchanger container material did not make a significant contribution on the melt fraction except for at very low thermal conductivities. Based on the theoretical results, stearic acid and acetamide are found to be good compatibility with latent heat storage system. It is also found that the initial temperature of PCM does not have very important ...
2008-05-15
Kneading of stearic acid into an extruder
Energy Technology Data Exchange (ETDEWEB)
An extruder used by kneading stearic acid (St acid) into it for the production of polystyrene for injection molding was studied. Most disadvantageous of kneading methods, melt-feed method, was applied because this method enables the utilization of existing facilities. St acid is discolored when the temperature surpasses 270{sup 0}C in nitrogen atmosphere, and the contact with metals intensifies the discoloring. The discoloring is more intensified by the contact with nitriding steel than with stainless steel. Residence time is 85 seconds, and even the contact with nitriding steel does not discolor ST acid when the temperature is lower than 270{sup 0}C. In the melt-feed method, when the die is in a bad shape, it brings about dead space at the tip of the die and St acid holds up there. When the kneading is in bad condition (St acid and polymer are hard to mix because their viscosities are quite different), St acid gathers between the barrel ...
1989-09-01
Heat transfer augmentation in a rectangular channel with a vee-shaped vortex generator
International Nuclear Information System (INIS)
The unsteady flow and heat transfer are simulated using LES and DNS for a channel with two angled ribs as a vee-shaped vortex generator to augment heat transfer. The vortex generators are attached on the bottom wall of the channel and their angles in respect to the main flow are between 10"o and 30"o. The Prandtl number is 0.71 and the Reynolds numbers based on the inflow velocity and the height of channel are from 200 to 2000. Based on the results of this work, the variations of the Nusselt number, pressure coefficient, bulk temperature, friction factor and Colburn factor with the Reynolds numbers and the incidence angles are provided. The relation between the key parameters of the velocity (friction factor f) and thermal (Colburn factor J) boundary layers is calculated for all cases and their values are compared with the predicted values by the Chilton-Colburn analogy. A comparison between the DNS and LES results is performed and it is found ...
2007-04-01
Formaldehyde exposure from building products
Energy Technology Data Exchange (ETDEWEB)
Formaldehyde release from building products is primarily due to incompletely reacted urea-formaldehyde resin (UFR) in particleboard, medium density fiberboard (MDF), and plywood. Formaldehyde is also released from urea-formaldehyde foam insulation (UFFI) that was popular during the 1970s for retrofitting building envelopes. Results of the authors test of commercial adhesives and UF-bonded wood products show that current state-of-the-art products yield air chamber test values below 0.25 mg/m/sup 3/ immediately after manufacture and are capable of meeting 0.12 mg/m/sup 3/ indoor air standards at the current product ratio unless these products are used in places where they are exposed to high temperature and humidity. In mobile homes placed in severe climates, wall-temperature profiles show large seasonal and diurnal variations that cause large changes in formaldehyde indoor air levels. The authors work shows that diurnal formaldehyde levels may ...
1986-01-01
International Nuclear Information System (INIS)
We have investigated the correlation between V-shaped defect formation and the optical properties of AlGaN/(In)GaN multiple quantum wells (MQWs) grown under different growth conditions and then demonstrated the characteristics of fabricated ultraviolet (UV) light emitting diodes (LEDs). From the temperature-dependent photoluminescence (PL) measurement, the internal quantum efficiency for 300 K was obtained as 43.6% for a sample with a low density of V-defects in a MQW and 13.7% for a sample with a high density of V-defects. The carrier lifetime based on the time resolved PL measurement at room temperature was 0.32 ns for a sample with a high density of V-defects and 1.26 ns for a sample with a low density of V-defects. And we also found that the density of V-defects affected the external quantum efficiency and wall plug efficiency of the fabricated UV LEDs. (fast track communication)
2008-07-07
Energy Technology Data Exchange (ETDEWEB)
Fe-Cr-Mn stainless steel is one of the candidate materials for the 1`st wall materials and structural applications of fusion reactor as regards reduced radioactivation properties than Fe-Cr-Ni austenitic stainless steels. This report deals with the effects of annealing and aging heat treatment on the microstructure, mechanical properties and corrosion resistance of Fe-Cr-Mn alloys varying Mn and W contents, which were made using vacuum high frequency induction furnace. Increasing Mn contents, austenite phase was increased, and maximum .epsilon. martensite phase was formed at about 21% Mn. W-addition made small amount of ferrite phase in the matrix, and the ferrite contents were increased with raising annealing temperature. Increased Mn contents reduced tensile stress and yield stress but increased the elongation. W-addition raised the high temperature tensile properties. The variation of Mn contents had no influenced on ...
1996-07-01
Energy Technology Data Exchange (ETDEWEB)
Debris coolability in the lower plenum of the reactor pressure vessel is an important factor for evaluation of debris in-vessel retention. The debris coolability analysis module is developed for the accurate prediction of the safety margin of the present reactor vessels in a severe accident. The module calculates debris spreading and cooling through melting and solidification in combination with a temperature distribution and failure evaluation of the vessel wall. Debris spreading is solved by the explicit method on a quasi-three-dimensional scheme and debris coolability is solved on the basis of natural convection analysis. The calculation for spreading is compared with a water spreading experiment on the floor and the calculation for coolability is compared with a n-octadecane melting experiment in a rectangular vessel. The comparisons show capabilities for predictions of spearhead transportation in the debris spreading process and of melting ...
1999-07-01
International Nuclear Information System (INIS)
Debris coolability in the lower plenum of the reactor pressure vessel is an important factor for evaluation of debris in-vessel retention. The debris coolability analysis module is developed for the accurate prediction of the safety margin of the present reactor vessels in a severe accident. The module calculates debris spreading and cooling through melting and solidification in combination with a temperature distribution and failure evaluation of the vessel wall. Debris spreading is solved by the explicit method on a quasi-three-dimensional scheme and debris coolability is solved on the basis of natural convection analysis. The calculation for spreading is compared with a water spreading experiment on the floor and the calculation for coolability is compared with a n-octadecane melting experiment in a rectangular vessel. The comparisons show capabilities for predictions of spearhead transportation in the debris spreading process and of melting ...
1999-04-19
International Nuclear Information System (INIS)
Sources of radon and pathways in which radon can reach dwelling-rooms are shortly discussed. In continuation of the previous measurements of radon in Swiss dwellings with track detectors and working level monitors, a complementary passive method for radon concentration measurements indoors and radon exhalation rate measurements from walls and soil surfaces is introduced. Radon decay products concentrations, air temperature gradients and wind velocities were measured continuously in four Swiss dwellings during several weeks in autumn and winter of 1985/86. The Rn-222 concentrations indoors ranged from about 10 Bq/m"3 in two houses in the Eastern Jura up to more than 23,000 Bq/m"3 in two houses situated in the Central Alps. Indoor equilibrium factors between 0.1 up to 0.5 with distinct dependences on floor-levels have been found. The influence of the temperature gradient between the oudoor and indoor air on the indoor radon ...
Development of modified 9 Cr-1 Mo steel for elevated-temperature service
International Nuclear Information System (INIS)
The status of development and commercialization of a modified 9 Cr-1 Mo alloy is presented. The alloy is modified by the addition of 0.06 to 0.10% Nb and 0.18 to 0.25% V. The alloy is recommended for use in the normalized and tempered condition (1040"0C for 1 h, air cooled to room temperature; 760"0C for 1 h, air cooled to room temperature). Heat treatment, Charpy impact, tensile, and creep properties of the alloy are described in detail along with a brief description of other properties. The modified alloy has creep strength that exceeds that of standard 9 Cr-1 Mo and 2 1/4 Cr-1 Mo steels for the temperature range from 427 to 704"0C. The total-elongation and reduction-of-area values for all test temperatures and rupture times up to 22,500 h exceed 15 and 70%, respectively. The estimated design allowable stresses for this alloy are higher than those for standard 9 Cr-1 Mo and 2 1/4 ...
1983-06-19
A thermochemical hydrogen production system based on a high-temperature fusion reactor blanket
International Nuclear Information System (INIS)
A conceptual fusion synfuel production system has been developed with the unique features of: (1) a fusion blanket producing high-temperature (1250"0C) process heat, and (2) the GA sulfur-iodine thermochemical cycle. The system incorporates a two-zone blanket which achieves a tritium breeding ratio of 1.1 while delivering a high fraction (30%) of the fusion heat at high temperatures (1250"0C). The multiple barriers to tritium permeation in the blanket design permit the hydrogen product to meet 10CFR20 regulatory requirements without stringent requirements on the tritium recovery systems. A ceramic heat exchanger, incorporating SiC tubes and headers to contain the process stream and a cooled, Inconel 718 pressure shell to contain the helium, was designed for transferring the heat from the high-temperature coolant to the process. A good heat-line match of the blanket heatsource temperature distribution to ...
1983-04-26
Glass Furnace Combustion and Melting Research Facility.
Energy Technology Data Exchange (ETDEWEB)
The need for a Combustion and Melting Research Facility focused on the solution of glass manufacturing problems common to all segments of the glass industry was given high priority in the earliest version of the Glass Industry Technology Roadmap (Eisenhauer et al., 1997). Visteon Glass Systems and, later, PPG Industries proposed to meet this requirement, in partnership with the DOE/OIT Glass Program and Sandia National Laboratories, by designing and building a research furnace equipped with state-of-the-art diagnostics in the DOE Combustion Research Facility located at the Sandia site in Livermore, CA. Input on the configuration and objectives of the facility was sought from the entire industry by a variety of routes: (1) through a survey distributed to industry leaders by GMIC, (2) by conducting an open workshop following the OIT Glass Industry Project Review in September 1999, (3) from discussions with numerous glass engineers, scientists, and executives, and (4) during visits to ...
2004-08-01
Energy Technology Data Exchange (ETDEWEB)
The kinetics of alkaline hydrolysis of methylparathion was studied at different temperatures (0-50 Centigrade) in the p H range of 8-12 by ultraviolet-visible absorption spectroscopy. Optimum p H and wavelength conditions were defined to carry out the simultaneous determination of methylparathion and one of its hydrolysis product, paranitrophenol, in buffered aqueous medium. Based on the experimental data and the mathematical equation of the kinetics, a rate constant (k) of first-order and an activation energy (Ea) of 9.2 Kcal/mol, were estimated. (Author) activation energy (Ea) of 9.2 Kcal/mol, were estimated. (Author)
1997-12-31
British Library Electronic Table of Contents (United Kingdom)
The molten salt reactor (MSR), which is one of the generation IV reactors, can meet the demand of transmutation and breeding. The thermodynamic properties of the molten salt system like LiF-NaF-BeF2 influence the design and construction of the fuel salt and coolant in the MSR for the new generation. In this paper, the equation of state of the ternary system 15%LiF-58%NaF-27%BeF2, over the temperature range from 873.15 to 1 073.15 K at one atmosphere pressure, is described using a modified Peng-Robinson (PR) equation. The densities of the ternary system and its components are estimated by this equation directly, and compared with the experimental data. Based on the equation of state, the other thermodynamic properties such as the enthalpy, entropy and heat capacity at constant pressure are ...
2007-01-01
Transfer of lead through the rats intestinal wall
International Nuclear Information System (INIS)
... females in vitro intestines lead 203 mucous membranes radionuclide kinetics
... presentation will be archived on the OR-Live website. 00:46:02 ANNOUNCER: This has been a ...
Statistical description and estimation of ocean drift ice environments
Energy Technology Data Exchange (ETDEWEB)
Part I of this thesis is on long-term iceberg collision-risk assessment methods for fixed offshore structures. Estimates for the long-term probability that an iceberg will hit a fixed offshore structure are based on estimates of the total volume of produced iceberg, a model for the size distribution of icebergs and a description of how iceberg trajectories ``fill`` the plane (the ocean`s surface). Part II of the thesis discusses methods for analysis of low resolution data in the sense that the size of the area covered by each pixel is not small compared to the dominating floes. Still, this type of data can provide estimates of the ice extent (and hence the ice edge) and ice concentration. The estimates of the ice edge (at least) seem to be physically significant in the sense that ``in some way`` they can reflect ice drift in an image time sequence. A priori this is far from obvious. A central idea is ...
1991-04-01
The paper investigates the effect of the wall heat flux ratio on the local heat transfer augmentation in a square channel with two opposite in-line ribbed walls for Reynolds numbers from 15,000 to 80,000. The square channel composed of 10 isolated copper sections has a length-to-hydraulic diameter ratio of 20. The rib height-to-hydraulic diameter ratio is 0.0625 and the rib pitch-to-height ratio equals 10. Six ribbed side to smooth side wall heat flux ratios are studied for four rib orientations. The results show that the ribbed side wall heat transfer augmentation increases with increasing ribbed side to smooth side wall heat flux ratios, but the reverse is true for the smooth side wall heat transfer augmentation. The average heat transfer augmentation of the ribbed side and smooth side wall decreases slightly with increasing ...
1992-10-01
Study of the thermal plasma etching at atmospheric pressure on silica rods
International Nuclear Information System (INIS)
Etching of SiO_2 rods has been obtained with a dc torch with argon as the process gas in an air environment at atmospheric pressure; the high temperature of the plasma jet causes vaporization of the exposed area. The apparatus and torch operative parameters have been set up to obtain a depth etch rate of up to 0.6 mm min"-"1 corresponding to 0.826 g min"-"1. An enthalpy probe has been employed to monitor the plasma conditions before the thermal plasma etching process and from the experimental etch rate a surface rod temperature of T_s_u_r = 2057 K has been derived. Etching has been obtained with uniformity over the entire exposed area with peak to peak differences below 1%. The plasma to rod heat transfer has been simulated using a commercial CFD code Fluent (copyright). The model consists of a non-steady two-dimensional simulation for a compressible turbulent fluid, with an adapted grid calculation. Boundary conditions have been set out using ...
2004-04-21
Investigation of corrosion experienced in a spray calciner/ceramic melter vitrification system
Energy Technology Data Exchange (ETDEWEB)
After periodic testing of a large-scale spray calciner/ceramic melter vitrification system over a 2-yr period, sufficient corrosion was noted on various parts of the vitrification system to warrant its disassembly and inspection. A majority of the 316 SS sintered metal filters on the spray calciner were damaged by chemical corrosion and/or high temperature oxidation. Inconel-601 portions of the melter lid were attacked by chlorides and sulfates which volatilized from the molten glass. The refractory blocks, making up the walls of the melter, were attacked by the waste glass. This attack was occurring when operating temperatures were >1200/sup 0/C. The melter floor was protected by a sludge layer and showed no corrosion. Corrosion to the Inconel-690 electrodes was minimal, and no corrosion was noted in the offgas treatment system downstream of the sintered metal filters. It is believed that most of the melter corrosion ...
1980-08-01
Energy Technology Data Exchange (ETDEWEB)
The theoretical analysis of a partially-ionized hydrogen gas flow (gas temperatures of approximately 10,000 to 20,000 K) through a particular class of magnetohydrodynamic (MHD) generators and the preliminary design of these MHD generators as open cycle, electric power supplies are performed. Analysis of the gas flow through these ultra-high temperature MHD generators requires a coupled gas dynamics/radiative heat transfer solution. Gas dynamics are modeled by a set of quasi-one-dimensional, nonlinear differential equations which account for friction, convective and radiative heat transfer and the interaction between the ionized gas and applied magnetic field. Radiative heat transfer is modeled using non-gray, absorbing-emitting two- and three-dimensional P-1 approximations which permit an arbitrary variation of the spectral absorption coefficient with frequency. Gas dynamics and radiative heat transfer are coupled through the energy equation, ...
1990-01-01
NMR studies of the partially disordered state in a triangular antiferromagnet UNi_4B
International Nuclear Information System (INIS)
A triangular antiferromagnet UNi_4B experiences a partially disordered state, in which two-thirds of U 5f moments order in a vertex-like structure and one-third of U 5f moments remain paramagnetic. Magnetization and NMR measurements of UNi_4B have been performed to study the dynamical properties of U magnetic moments in the partially disordered state. The value of the effective moment above T_N derived from the fitting of the Curie-Weiss law suggests a significant crystal field splitting and the Kondo effect. The Weiss temperature was also estimated to be -28 K, which suggests that the exchange interaction is antiferromagnetic. Furthermore, the exchange interaction estimated from the relaxation rate T_1"-"1 above 50 K is 18 K, which is close to the Weiss temperature. These results suggest that the dominant interactions between U moments are antiferromagnetic in the basal plane. The relaxation rate ...
2007-04-11
Involvement of the chest and abdominal wall as a rare manifestation in Hodgkin's disease
Energy Technology Data Exchange (ETDEWEB)
Radiological findings of chest and abdominal wall involvement in Hodgkin's disease are reported. This manifestation was diagnosed in one patient in the primary staging and in two patients during the course of the disease. Typical radiological findings are soft tissue masses in the chest and abdominal wall, in two cases with continous tumor growth of enlarged mediastinal lymphnodes into the anterior chest wall. The axial computed tomography is the best method to evaluate the extent of chest and abdominal wall involvement in Hodgkin's disease.
1983-03-01
May 25, 2007 ... The NASA Cost Estimating Handbook brings the fundamental concepts and techniques of cost estimating to NASA personnel in a way that ...
A Program Manager's Guide for Software Cost Estimating
... A PROGRAM MANAGER'S GUIDE FOR SOFTWARE COST ESTIMATING ... This thesis provides a broad view of the software cost estimating process. ...
2002-12-01
Energy Technology Data Exchange (ETDEWEB)
The paper discusses multiaxial, isothermal and thermocyclic experiments with tubes made of the austenitic steel 1.4909 (AISI 316 L(N)). The thermocyclic stress is induced by periodic, inductive heating of the tube outer wall and simultaneous, continuous water cooling of the inner wall. Temperature gradients above 100 K/mm are measured, which cause fatigue cracking, predominantly in the inner wall. The experiments with the isothermally stressed tube specimens are intended to simulate the equi-biaxial stress conditions that are typical of the thermocyclic stress regime. This stress regime is created by superimposed longitudinal stress (tension/compression), and circumferential stress (internal/external compression). A novel test bench was realised specifically for the experiments. The paper explains design, operation, and measuring techniques, especially of the circumferential strain measurements. The ...
1993-12-31
Application of the porous media model for the LWR process components
Energy Technology Data Exchange (ETDEWEB)
Full text of publication follows: A porous media solution PORFLO has been developed for the 3-dimensional two-phase flow by describing the process facility in Cartesian or cylindrical coordinates. The local porosity fraction is applied for distinguishing the fluid filled volumes from the solid structures. The solid structure contribute the two-phase flow through the wall friction, flow area and heat transfer. Optionally the solid structure may contain primary liquid of steam generators, steam in the higher temperature and pressure to be condensed or electrical heating power. By using these optional boundary conditions three different process facilities have been analysed. The thermohydraulic solution based on 5-equation approach, where the conservation equations are solved for the liquid and gas (vapour) mass, mixture momentum (giving the velocity only for the mixture), liquid and gas energy, is described shortly. In addition to that the ...
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
The 1977 version of the Simpson-Puls-Dutton model appears to be the most amenable with respect to utilizing known or readily estimated quantities. The Pardee-Paton model requires extensive calculations involving estimated quantities. Recent observations by Koike and Suzuki on vanadium support the general assumption that crack growth in hydride forming metals is determined by the rate of hydride formation, and their hydrogen atmosphere-displacive transformation model is of potential interest in explaining hydrogen embrittlement in ferrous alloys as well as hydride formers. The discontinuous nature of cracking due to hydrogen embrittlement appears to depend very strongly on localized stress intensities, thereby pointing to the role of microstructure in influencing crack initiation, fracture mode and crack path. The initiation of hydrogen induced failures over relatively short periods of time can be characterized with fair reliability using ...
1982-04-01
British Library Electronic Table of Contents (United Kingdom)
We used a radiation-transfer equation estimate of July surface temperatures (Ts) in China's Yongding River basin based on thermal infrared Landsat TM images from 1987 and 2005 and Landsat ETM+ images from 2000. Based upon the Ts-NDVI relationship space, we analyzed the scatterplot of Ts versus NDVI to calculate a temperature-vegetation dryness index (TVDI). We used a linear regression model between soil moisture and TVDI to estimate soil moisture to depths of 10 and 20cm. We produced a land use and cover type map by classification of the Landsat images, and used the map to study the influence of land use and cover type changes on soil moisture. Some areas of farmland in 1987 had been converted into grassland by 2000, and soil moisture mainly increased, with increases ranging from 20 to 60%...
2010-01-01
Measuring characteristics on emissivity using infrared thermometer for RCCS
International Nuclear Information System (INIS)
In VHTGR (Very High Temperature Gas-cooled Reactor), the radiation plays an important role in heat transfer through the cavity in RCCS (Reactor Cavity Cooling System). We performed the series of experiments to measure the emissivity using the infrared thermometer with wavelength range of 8#approx#14 #mu#m. As the first step, the transmittance of Zinc Selenide (ZnSe) window was measured to estimate the emissivity that can compensate the attenuation effect of window. The kind of gas with various concentrations in the cavity will be released during postulated accidents to the coolant type, so it is essential to estimate the effects of gas on the measurement of emissivity. In this manner we measured the emissivity with the air, the helium and the steam inside chamber. The results represent that the concentration of the air and the helium do not affect the emissivity significantly while the steam decreases the measured ...
2004-12-01
Energy Technology Data Exchange (ETDEWEB)
The thermal and heat transfer characteristics of stearic acid during the solidification processes were investigated experimentally in a vertical annulus energy storage system. The temperature distribution and temperature variations with time at different radial positions during the freezing processes were obtained. The thermal characteristics of the stearic acid, including movement of the solid-liquid interface in the radial direction, and the effects of Reynolds number on the heat transfer parameters were studied. The heat flux was estimated by using a simple approximate model. A new copper fin was designed and fixed to the electrical heating rod to enhance the thermal conductivity of the stearic acid. The results show that the new fin can enhance both the conduction and the natural convection heat transfer of the PCM, and the enhancement factor during solidification is estimated to be as high as 250%. ...
2005-04-01
Energy Technology Data Exchange (ETDEWEB)
The thermal and heat transfer characteristics of stearic acid during the solidification processes were investigated experimentally in a vertical annulus energy storage system. The temperature distribution and temperature variations with time at different radial positions during the freezing processes were obtained. The thermal characteristics of the stearic acid, including movement of the solid-liquid interface in the radial direction, and the effects of Reynolds number on the heat transfer parameters were studied. The heat flux was estimated by using a simple approximate model. A new copper fin was designed and fixed to the electrical heating rod to enhance the thermal conductivity of the stearic acid. The results show that the new fin can enhance both the conduction and the natural convection heat transfer of the PCM, and the enhancement factor during solidification is estimated to be as high as 250%. ...
2005-04-01
Energy Technology Data Exchange (ETDEWEB)
This paper reports the estimates concerning the atmospheric carbon dioxide absorption and storage by living plants all over the world. It is necessary to decrease atmospheric carbon dioxide concentrations for avoiding global warming. As living plants absorb carbon dioxide by photosynthesis and accumulate carbon in their bodies, they can play an important role to remove atmospheric carbon dioxide. Literatures describing distribution areas, biomass values and net primary productivity (NPP) of forests, marine plants and microorganisms were collected. Examining those data, the biomass and NPP of forests, marine plants and microorganisms can be summarized as follows: (1) Forest biomass and their NPP of the world. The world's forest area is recently estimated as 4 billion hectares, and their biomass is about 400 billion tons of carbon which is equal to 2/3 of the total atmospheric carbon. The NPP of the world's forest is ...
1992-01-01
The nucleation kinetics of calcium sulfate dihydrate in NaCl solutions up to 6 m and 90 C
Energy Technology Data Exchange (ETDEWEB)
The crystallization of calcium sulfate from aqueous solutions with NaCl is both geological and industrial interest because NaCl is the dominant solute in natural brines and many industrial fluids. Induction periods for the nucleation of calcium sulfate dihydrate were experimentally determined as a function of supersaturation in NaCl solutions from 0 to 6 m at 25 C and in 3.0-m NaCl solutions at temperatures from 25 to 90 C. Using classic nucleation theory, the interfacial tension between gypsum and 3.0-m NaCl solution was estimated to be about 39 mJ/m[sup 2] at 25 C and increases with increasing temperature (to 63 mJ/m[sup 2] at 90 C). It was observed that the induction period decreases with increasing NaCl concentrations up to 3 m and then starts to increase slightly at a given temperature and saturation state. The electrolyte effect on nucleation was proportional to the enhanced solubility of calcium ...
1994-02-01
International Nuclear Information System (INIS)
Data by Wiesmann et al. on the temperature coefficient of the upper critical field, dH/sub c/2(T)/dT, and the normal-state resistivity rho_0 near the superconducting transition temperature T/sub c/ are analyzed to estimate the bare density of states N (E/sub F/) as a function of structural disorder and T/sub c/ in various #alpha#-particle irradiated samples of A-15 Nb_3Ge and Nb_3Sn. By taking into account the change in the electron-phonon coupling strength with T/sub c/ and the effect of mass enhancement arising from the electron-phonon interaction, the results of the new analysis indicate that (i) the drop in N (E/sub F/) for Nb_3Ge is relatively small as T/sub c/ changes from approx. 21 to approx. 4 K, in agreement with a recent low-temperature specific-heat measurement; (ii) the value of N (E/sub F/) in Nb_3Sn decreases by a factor of approx. 4 as T/sub c/ varies from approx. 18 to approx. 3 K. The ...
Gastric dilatation-volvulus (GDV) is a life-threatening condition in dogs and other species in which the stomach dilates and rotates on itself. The etiology of the disease is multi-factorial, but explicit precipitating causes are unknown. This study sought to determine if there was a significant association between changes in hourly-measured temperature and/or atmospheric pressure and the occurrence of GDV in the population of high-risk working dogs in Texas. The odds of a day being a GDV day, given certain temperature and atmospheric pressure conditions for that day or the day before, was estimated using logistic regression models. There were 57 days in which GDV(s) occurred, representing 2.60% of the days in the 6-year study period. The months of November, December, and January collectively accounted for almost half (47%) of all cases. Disease risk was negatively associated with daily maximum ...
2008-01-01
Aminated poly(vinyl chloride) (PVC) membranes were prepared that had a Nernstian response over a wide range of pH. The reaction between PVC and methyl-piperazine (MePIP) in dimethylformamide (DMF) was studied over a wide range of time and temperature, and in the presence of the catalyst, potassium fluoride (KF). Time, temperature, and KF increased the nitrogen (N) content of the resulting polymers, but sometimes at the expense of decreasing their specific viscosities (molecular weights). Activation energies of processes that occurred in different temperature ranges were estimated assuming an Arrhenius relationship. A Nernstian response occurred once the N content approached to about 0.3 w/w %, and was accelerated by the presence of KF at elevated temperatures. Increasing the N content above about 3% led to a loss of the Nernstian response either because of an increase in the double ...
1998-03-15
Energy Technology Data Exchange (ETDEWEB)
A number of binary geothermal cycles utilizing mixed hydrocarbon working fluids were analyzed with the overall objective of finding a working fluid which can produce low-cost electrical energy using a moderately-low temperature geothermal resource. Both boiling and supercritical shell-and-tube cycles were considered. The performance of a dual-boiling isobutane cycle supplied by a 280/sup 0/F hydrothermal resource (corresponding to the 5 MW pilot plant at the Raft River site in Idaho) was selected as a reference. To investigate the effect of resource temperature on the choice of working fluid, several analyses were conducted for a 360/sup 0/F hydrothermal resource, which is representative of the Heber resource in California. The hydrocarbon working fluids analyzed included methane, ethane, propane, isobutane, isopentane, hexane, heptane, and mixtures of those pure hydrocarbons. For comparison, two fluorocarbon refrigerants were also analyzed. ...
1981-02-01
`TUNDTEMP` - an advisory tool for the continuous steel casting process
Energy Technology Data Exchange (ETDEWEB)
This report summarizes the major features of the advisory tool `TUNDTEMP`, developed to act as a decision support in the continuous steel casting process. `TUNDTEMP` provides a means to predict abnormal phenomena of temperature origin in the casting that may be difficult to foresee in practical situations. The heart of the system is a semi-empirical calculation model that yields an estimate of the evolution of the tundish temperature of the liquid steel on the basis of a few important casting factors. The user interface of the system is to a large extent based on the visual presentation of the simulated results. The system also contains an optional rule based mechanism that provides assistance in the result interpretation and, if wished, linguistically formulates action recommendations. A separate program has been built for the tuning of the calculation model and for maintenance of the system. At the end of the report, the ...
1993-11-01
Tungsten coating on low activation vanadium alloy by plasma splay process
International Nuclear Information System (INIS)
Tungsten (W) coating on fusion candidate V-4Cr-4Ti (NIFS-HEAT-2) substrate was demonstrated with plasma spray process for the purpose of applying to protection of the plasma facing surface of a fusion blanket. Increase in plasma input power and temperature of the substrate was effective to reduce porosity of the coating, but resulted in hardening of the substrate and degradation of impact property at 77 K. The hardening seemed to be due to contamination with gaseous impurities and deformation by thermal stress during the coating process. Since all the samples showed good ductility at room temperature, further heating seems to be acceptable for the vanadium substrate. The fracture stress of the W coating was estimated from bending tests as at least 313 MPa, which well exceeds the design stress for the vanadium structure in fusion blanket. (author)
2008-03-01
International Nuclear Information System (INIS)
The partial pressures of the components (ThCl_4, MCl and MThCl_5) in the saturated vapours of ThCl_4 solutions in molten LiCl, NaCl, KCl, RbCl and CsCl are determined as a function of temperature (900 to 1200 K) and ThCl_4 concentration (2 to 50 mol% ThCl_4) by dynamic method. Thorium tetrachloride volatility is shown to exceed that of alkali chloride from the melts containing less than 98 LiCl or NaCl, 83 KCl, 67 RbCl and 48 mol% CsCl. From experimental observations the decomposition potential of the electrolytes under investigation was estimated in temperature and concentration ranges of our measurements. Under otherwise equal conditions, it increases in the series of alkali chlorides from LiCl to CsCl. (author).
1984-01-01
Study on cold startability and mixture formation of high-percentage methanol blends
Energy Technology Data Exchange (ETDEWEB)
Using gasoline as an example of additives for cold start improvement, fuel vapor composition of methanol-gasoline mixtures, fuel evaporation rate in consideration of temperature drop due to heat of fuel evaporation, air fuel ratio, stoichiometric air fuel ratio and excess air ratio of fuel vapor were calculated. The mixture formation of methanol-gasoline mixtures at low temperature in otto cycle engines was studied. Van Laar's empirical formula was used to estimate the partial pressure of high-percentage methanol blends. It was found that the most part of fuel vapor is occupied by gasoline, even when a small amount of gasoline is added to methanol resulting to an extremely small excess air ratio. It is obvious that this vapor pressure adjustment using gasoline is the dominant factor for improvement in cold startability. (10 figs, 1 tab, 10 refs)
1988-05-31
Sound velocity of glassy Pd{sub 80}Si{sub 20} after heavy-ion irradiation at low temperatures.
Energy Technology Data Exchange (ETDEWEB)
Specimens of glassy Pd{sub 80}Si{sub 20} were irradiated at temperatures below 100K with 3.5 MeV krypton ions. After irradiation, changes in the sound velocity were measured at 80 K without warm-up by Brillouin scattering. The sound velocity decreased with increasing ion fluence and exponentially approached a saturation value of -4.7%. The change in the shear elastic modulus per unit concentration n of defects was estimated to be d(ln C)/dn = -9.4 to -4.7. The results of the present study are compared with changes in the elastic properties predicted recently by an interstitialcy model for glassy metals, and with the elastic properties of glassy metals after thermal treatment.
2002-01-01
Energy Technology Data Exchange (ETDEWEB)
A back-propagation neural network technique is used at JET to extract plasma parameters like ion temperature, rotation velocities or spectral line intensities from charge exchange (CX) spectra. It is shown that in the case of the C VI CX spectra, neural networks can give a good estimation (better than +-20% accuracy) for the main plasma parameters (Ti, V{sub rot}). Since the neural network approach involves no iterations or initial guesses the speed with which a spectrum is processed is so high (0.2 ms/spectrum) that real time analysis will be achieved in the near future. 4 refs., 8 figs.
1994-07-01
Monitoring transplanting operation of rice crop using passive microwave radiometer data
British Library Electronic Table of Contents (United Kingdom)
This study highlights a methodology to detect the transplanting operation of wetland rice at a regional scale using SSM/I brightness temperature in frequencies like 19, 37 and 85 GHz with vertical polarization. A cloud removal algorithm was used to make weekly composites of the brightness temperature, which were used to estimate the soil wetness index (SWI). Flooding of rice fields with water for transplanting induces very high change in SWI due to contrasting dielectric constant of water (80) and soil (4). Different weather conditions and fractional wet area under the footprint of sensor affect SWI, hence absolute value of SWI was not adequate. Therefore, multi-year SWI anomaly was used to generate a threshold value of SWI change to detect when SWI change between two consecutive weeks was...
2011-01-01
Horizontal ground coupled heat pump: Thermal-economic modeling and optimization
Energy Technology Data Exchange (ETDEWEB)
The modeling and optimizing processes of a Ground Coupled Heat Pump (GCHP) with closed Horizontal Ground Heat eXchanger (HGHX) are presented in this paper. After thermal modeling of GCHP including HGHX, the optimum design parameters of the system were estimated by minimizing a defined objective function (total of investment and operation costs) subject to a list of constraints. This procedure was performed applying Genetic Algorithm technique. For given heating/cooling loads and various climatic conditions, the optimum values of saturated temperature/pressure of condenser and evaporator as well as inlet and outlet temperatures of the water source in cooling and heating modes were predicted. Then, for our case study, the design parameters as well as the configuration of HGHX were obtained. Furthermore, the sensitivity analysis of change in the total annual cost of the system and optimum design parameters with the climatic ...
2010-12-15
Estimating extreme values of thermal gradients in concrete structures
British Library Electronic Table of Contents (United Kingdom)
Temperature variations due to climate changes are a major cause of movements in a concrete structure, both in the longitudinal and transversal directions and between different parts of the structure. If these movements are restrained, stresses will be induced which may contribute to cracking. The movements are caused by complex interactions of several factors such as solar radiation, air temperature, long-wave heat radiation and wind speed. To predict the varying thermal conditions in a concrete structure a finite element model has been used. A validation of the model has been performed using field measurements in a concrete slab together with climate data from the Swedish Meteorological and Hydrological Institute to be able to use the model for simulations over long time periods and for s...
2011-01-01
Application of the CFAST zone model to the Fire PSA
British Library Electronic Table of Contents (United Kingdom)
The integrity of the cables located in the target room is very important in the Fire PSA, because the CDF and CCDP are changed according to the results of a cable integrity that depends on the surrounding gas temperature. The conservative assumptions used in the Fire PSA typically specify that all of the equipment and cables of a room would fail when a fire happens in the room. But the realistic assessment of a fire risk by using a fire simulation tool has become necessary in the Fire PSA as described in the ANS Fire PRA Standard. This paper evaluates the cable integrity of eight pump rooms in the nuclear power plant by using the CFAST zone fire model. The upper layer gas temperature of each room is estimated, and an analysis based on the results of model simulations is used to judge the c...
2010-01-01
Absorption of carbonyl sulfide in aqueous methyldiethanolamine
Energy Technology Data Exchange (ETDEWEB)
The absorption of carbonyl sulfide in aqueous methyldiethanolamine (MDEA) was studied over a range of temperatures and MDEA concentrations. MDEA is commonly used for selective absorption of hydrogen sulfide in the presence of carbon dioxide. However, sulfur in the form of COS may also be present and it is necessary that estimates of absorption rates of this compound be made. The objective of this study is to determine the physiochemical properties needed to predict COS absorption rates in aqueous MDEA. Free gas solubility and the diffusivity of COS in MDEA solutions were measured over the temperature range 15 to 40{sup 0}C for MDEA concentrations up to 30 weight per cent using the nitrous oxide analogy method. Solubilities were measured volumetrically in an equilibrium cell and diffusivities were measured using a laminar liquid jet absorber. The kinetics of the reaction between COS and MDEA were studied by measuring ...
1988-01-01
What's happening out there? (Climatic change impacts)
International Nuclear Information System (INIS)
This article briefly comments on some stumbling-blocks to climatic change modelling accuracy - in assessments of the greenhouse effect, 25% (missing link) of atmospheric carbon dioxide absorption is still unaccounted for; 1989 World Bank estimates of the Amazon rain forest deforestation rate have since proven to be inaccurate; there are difficulties in assessing the movement of the earth's crust relative to variations in sea level; and different studies vary in results relative to global temperature measurement and trend assessment. The need for an assessment of the economic impacts of increased atmospheric concentrations of carbon dioxide is also pointed out.
1990-01-01
Energy Technology Data Exchange (ETDEWEB)
A comprehensive Scanning Tunneling Microscopy (STM) study of submonolayer nucleation and growth of 2D islands in Ag/Ag(100) homoepitaxy for temperature between 295K and 370K is presented. The initial stages of multilayer kinetic roughening is also studied. Analysis of an appropriate model for metal (100) homoepitaxy, produces estimates of 350 meV for the terrace diffusion barrier, 400 meV for the adatom bond energy, and 25 meV for the additional Ehrlich-Schwoebel step-edge barrier.
1996-08-01
Energy Technology Data Exchange (ETDEWEB)
A simple theory for predicting the convective energy loss from side-facing cavity receivers in windless environments has been developed. The approach used is to determine the velocity distribution of the incoming air in the aperture plane (and thereby the rate of mass entrainment); and then to estimate the bulk temperature of the heated emerging air. The convective loss is then calculated from an energy balance. To illustrate this theory, numerical results applicable to the 2.15 meter cubic cavity being tested in the laboratory are provided.
1981-01-01
Neutron star evolution with internal heating
Energy Technology Data Exchange (ETDEWEB)
The thermal evolution predicted by current models of the superfluid-crust interaction is noted to differ substantially from the thermal evolution predicted by models without internal heating as well as previous models of heating. Heating rates approaching the maximum predicted by current models enhance the photon luminosity of the star in the neutrino cooling era, and dramatically alter the thermal evolution in the photon cooling era. Standard cooling models are consistent with current pulsar temperature estimates and upper limits, except those for the Vela pulsar, which are lower than predicted. 77 refs.
1989-11-01
International Nuclear Information System (INIS)
The self-consistent relativistic linearized-augmented-plane-wave method is applied to local-density calculation of electronic structure of TmS. It is found that thulium monosulphide is a compound with a trivalent state of thulium. The influence of spin-orbital interaction is shown for different symmetry states of electrons. Calculated densities of states are used for the estimation of the electron-phonon coupling constant. And in conclusion it is shown that TmS is a high temperature Kondo-like system. (author).
Energy Technology Data Exchange (ETDEWEB)
Numerical analysis of solar dish modified cavity receiver with Cone, CPC and Trumpet reflectors is presented. Three-dimensional modeling is carried out to estimate the convective and radiative heat loss from the receiver for different angles of inclination and operating temperatures. Incorporating reflectors in the modified cavity receiver for second stage concentration, the natural convection heat losses are reduced by 29.23, 19.81 and 19.16%, respectively. The receiver with the trumpet reflector has shown better performance as compared to other configurations. (orig.)
2009-01-15
Analysis of the thermal performance of dynamic solar systems
Energy Technology Data Exchange (ETDEWEB)
This article proposes a model for estimating the effect of the overall thermal resistance of the absorber and the coolant on a solar thermal energy system utilizing advanced heat transfer mediums. Two equations can be used to model a dynamic system: one for the maximum conversion efficiency and one to specify the constraint that, in quasi-steady state, the net energy collected must be transferred to the coolant. These two equations define a constrained optimization problem in two variables, the fluid and the absorber temperatures. The results present interesting implications for liquid metal, direct absorption, and solar evaporating systems.
1996-03-01
An analysis of convective losses from cavity solar central receivers
Energy Technology Data Exchange (ETDEWEB)
A simple analytical model has been developed in order to provide a framework for designing experimental programs for convective loss determinations, for analyzing available experimental data from solar receiver test programs, and for estimating the convective loss at a relatively small cost. Analytical results and experimental evidence indicate that the convective loss from cavity receivers is appreciable, while the effects of wind on the convective loss under normal operating conditions are minimal. The proposed analytical model provides a means of determining the relative importance of the internal resistances and predicting the bulk air temperature within the convective zone inside the cavity.
1981-01-01
AFS Cupola Model Verification--Initial Investigations
The cupola furnace is used to melt scrap steel, pig iron, foundry returns, and alloying additives to a prescribed tapping chemistry and temperature for iron casting applications. The melting process within the cupola is highly complex and not well quantified. The American Foundrymen's Society is developing a mathematical model to aid in the understanding of these processes. This model is reaching maturity, and has been successful in estimating a number of melting parameters. This paper details the results of efforts to verify the model in a controlled system, equipped wit the appropriate sensors, for model verification. The work was performed on a research-scale cupola furnace located at the Department of Energy's Albany Research Center.
1998-01-01
A NEM diffusion code for fuel management and time average core calculation
International Nuclear Information System (INIS)
A computer code based on Nodal expansion method has been developed for solving two groups three dimensional diffusion equation. This code can be used for fuel management and time average core calculation. Explicit Xenon and fuel temperature estimation are also incorporated in this code. TAPP-4 phase-B physics experimental results were analyzed using this code and a code based on FD method. This paper gives the comparison of the observed data and the results obtained with this code and FD code. (author)
2005-11-01
Ultra-high temperature strength properties on Mod.9Cr-1Mo steel
Energy Technology Data Exchange (ETDEWEB)
A sodium-water reaction drove from the single tube break in steam generator of FBR might overheat labor tubes rapidly under internal pressure loadings. If the temperature of tube wall becomes too high, it has to be evaluated that the stress of tube does not exceed the material strength limit to prevent the propagation of tube rupture. This study clarified the tensile and creep properties of Mod.9Cr-1Mo steel at ultra-high temperature which will be used in evaluation of the tube burst by sodium-water reaction. The strain rates for tensile test are from 10%/min to 10%/sec, and creep-rupture time is maximum 277sec. The range of test temperature is 700degC to 1300degC. The main results obtained were as follows; (1) The evaluation data on the relationship between tensile strength and strain rate and creep-rupture strength in shorter time on Mod.9Cr-1Mo steel were acquired. (2) Short-term mechanical ...
2000-03-01
Adsorption of ethylene and ethane on graphitized thermal carbon black and in slit pores whose walls are composed of graphene layers is studied in detail to investigate the packing efficiency, the two-dimensional critical temperature, and the variation of the isosteric heat of adsorption with loading and temperature. Here we used a Monte Carlo simulation method with a grand canonical Monte Carlo ensemble. A number of two-center Lennard-Jones (LJ) potential models are investigated to study the impact of the choice of potential models in the description of adsorption behavior. We chose two 2C-LJ potential models in our investigation of the (i) UA-TraPPE-LJ model of Martin and Siepmann for ethane and Wick et al. for ethylene and (ii) AUA4-LJ model of Ungerer et al. for ethane and Bourasseau et al. for ethylene. These models are used to study the adsorption of ethane and ethylene on graphitized thermal carbon black. It is found ...
2004-12-01
Trace elements in the Allende meteorite
International Nuclear Information System (INIS)
New RNAA determinations of Ba, Sr, Zr, U, Re, Pd, Ag, Zn and Se and INAA measurements of Lu are added to published data for 21 other elements in the same suite of ten samples. On the average, 21 refractory elements are not significantly fractionated from one another. The mean of their enrichment factors relative to C1 chondrites is 17.5 +- 0.4, indicating that the high-temperature condensate inclusions represent 5.7 wt% of the total condensable matter. Os, Ir, Ru, Re and most of the W condensed in one or more refractory siderophile element alloys along with small fractions of the Pd, Co, Au and Ag. The bulk of the Eu and Sr condensed in solid solution in melilite. Sc, Zr, Hf, Ta, U and the remaining REE condensed in a phase whose abundance in the inclusions in negatively correlated with that of melilite, either diopside or one or more minor or trace phases, including perovskite. Ba condensed in a different phase, separately from all these elements. In individual ...
1977-01-01
Energy Technology Data Exchange (ETDEWEB)
Temperature data to depths of a few hundred meters were obtained from 29 wells in northeastern Arizona; 12 in the region surrounding the San Francisco Volcanic Field, 8 in the Black Mesa area, and 9 in the south-central Colorado Plateau which includes the White Mountains. Although there was evidence for local hydrologic disturbances in many temperature profiles, most wells provided an estimate of the conductive thermal gradient at the site. A few thermal conductivities were measured and were combined with published regional averages for the north-central part of the Colorado Plateau to produce crude estimates of regional heat flux. None of the wells was accessible below the regional aquifers. To these depths, heat flow in the area of the San Francisco Volcanic Field appears to be controlled primarily by regional lateral water movement having a significant downward vertical component of velocity. The ...
1982-01-01
Energy Technology Data Exchange (ETDEWEB)
In 1996, the National Marine Fisheries Service and the University of Washington completed the fourth year of a multi-year study to estimate survival of juvenile salmonids (Oncorhynchus spp.) passing through dams and reservoirs on the Snake River. Actively migrating smolts were collected near the head of Lower Granite Reservoir and at Lower Granite Dam, tagged with passive integrated transponder (PIT) tags, and released to continue their downstream migration. Individual smolts were subsequently detected at PIT-tag detection facilities at Lower Granite, Little Goose, Lower Monumental, McNary, John Day and Bonneville Dams. Survival estimates were calculated using the Single-Release (SR) and Paired-Release (PR) Models. Timing of releases of tagged hatchery steelhead (O. mykiss) from the head of Lower Granite Reservoir and yearling chinook salmon (O. tshawytscha) from Lower Granite Dam in 1996 spanned the major portion of their juvenile migrations. ...
1998-02-01
X-ray ablation measurements and modeling for ICF applications
Energy Technology Data Exchange (ETDEWEB)
X-ray ablation of material from the first wall and other components of an ICF (Inertial Confinement Fusion) chamber is a major threat to the laser final optics. Material condensing on these optics after a shot may cause damage with subsequent laser shots. To ensure the successful operation of the ICF facility, removal rates must be predicted accurately. The goal for this dissertation is to develop an experimentally validated x-ray response model, with particular application to the National Ignition Facility (NIF). Accurate knowledge of the x-ray and debris emissions from ICF targets is a critical first step in the process of predicting the performance of the target chamber system. A number of 1-D numerical simulations of NIF targets have been run to characterize target output in terms of energy, angular distribution, spectrum, and pulse shape. Scaling of output characteristics with variations of both target yield and hohlraum wall thickness are ...
1996-09-01
Energy Technology Data Exchange (ETDEWEB)
Real time neutron radiography has been used to study the dynamic behavior of two phase flow and measure the time averaged vapor fraction in a heated metal tube containing boiling steam water operating at up to 15 bar pressure. The neutron radiographic technique is non-intrusive and requires no special transparent window region. This is the first time this technique has been used in an electrically heated pressurized flow loop. This unique experimental method offers the opportunity to observe and record on videotape, flow patterns and transient behavior of two phase flow inside opaque containers without disturbing the environment. In this study the test sections consisted of stainless steel tubes with a 1.27 cm outer diameter and wall thicknesses of 0.084 cm and 0.124 cm. The experiments were carried out at the Pennsylvania State University 1 megawatt TRIGA reactor facility utilizing a Precise Optics neutron radiography camera. The inlet water ...
1998-02-01
International Nuclear Information System (INIS)
Real-time neutron radiography has been used to study the dynamic behavior of two-phase flow and measure the time averaged vapor fraction in a heated metal tube containing boiling steam-water operating at up to 15 bar pressure. The neutron radiographic technique is non-intrusive and requires no special transparent window region. This is the first time this technique has been used in an electrically heated pressurized flow loop. This unique experimental method offers the opportunity to observe and record on videotape, flow patterns and transient behavior of two-phase flow inside opaque containers without disturbing the environment. In this study the test sections consisted of stainless steel tubes with a 1.27 cm outer diameter and wall thicknesses of 0.084 and 0.124 cm. The experiments were carried out at the Pennsylvania State University 1 MW TRIGA reactor facility utilizing a Precise Optics neutron radiography camera. The inlet water ...
1999-11-03
International Nuclear Information System (INIS)
Real time neutron radiography has been used to study the dynamic behavior of two phase flow and measure the time averaged vapor fraction in a heated metal tube containing boiling steam water operating at up to 15 bar pressure. The neutron radiographic technique is non-intrusive and requires no special transparent window region. This is the first time this technique has been used in an electrically heated pressurized flow loop. This unique experimental method offers the opportunity to observe and record on videotape, flow patterns and transient behavior of two phase flow inside opaque containers without disturbing the environment. In this study the test sections consisted of stainless steel tubes with a 1.27 cm outer diameter and wall thicknesses of 0.084 cm and 0.124 cm. The experiments were carried out at the Pennsylvania State University 1 megawatt TRIGA reactor facility utilizing a Precise Optics neutron radiography camera. The inlet water ...
1998-03-16
Sensitivity study of CFD turbulent models for natural convection analysis
Energy Technology Data Exchange (ETDEWEB)
The buoyancy driven convective flow fields are steady circulatory flows which were made between surfaces maintained at two fixed temperatures. They are ubiquitous in nature and play an important role in many engineering applications. Application of a natural convection can reduce the costs and efforts remarkably. This paper focuses on the sensitivity study of turbulence analysis using CFD (Computational Fluid Dynamics) for a natural convection in a closed rectangular cavity. Using commercial CFD code, FLUENT and various turbulent models were applied to the turbulent flow. Results from each CFD model will be compared each other in the viewpoints of grid resolution and flow characteristics. It has been showed that: -) obtaining general flow characteristics is possible with relatively coarse grid; -) there is no significant difference between results from finer grid resolutions than grid with y{sup +} < 0.35, where y{sup +} is defined as y{sup +} = ...
2007-07-01
Results and recommendations from studies of basic handling characteristics of solid biomass fuels
Energy Technology Data Exchange (ETDEWEB)
Main results are summarised for a project carried out with the aim of increasing the knowledge of relations between handling characeristics and properties such as moisture content, particle size and shape etc. Handling characteristics that were studied: angle of repose, friction between fuel and different surfaces, the fuel`s tendency to bridge across openings, and its freezing characteristics. Some forty solid biomass fuels were studied, mainly wood fuels, with particle sized from 1 to 200 mm. New methods were developed for measurement of bridging across openings and freezing characeristics. The angle of repose varied between 25 and 55 deg. The particle shape had a significant influence, a high ratio of length/thickness gave a high angle of repose. When the fuel moisture content was increased the angle of repose first increased, then decreased, and finally increased again. The particle size had no influence. The friction depended more on the surface than on the fuel properties. ...
1996-12-31
Phosphor plasters of CaSO{sub 4}:Dy on the courtyard wall of Djehuty's tomb (Luxor, Egypt)
Energy Technology Data Exchange (ETDEWEB)
The X-ray diffraction (XRD) and environmental scanning electron microscopy (ESEM) analyses of plasters collected from the courtyard walls of Djehuty's tomb show anhydrite, calcite, dolomite, quartz, alkali feldspars and accessorial amounts of halite and illite. The external outer bed is mainly composed by anhydrite, since the original hydrous phases of gypsum plaster were desiccated during thirty centuries in the dry land environment of the Luxor area, under low relative humidity and high temperatures. The luminescence analyses by thermoluminescence (TL) and cathodoluminescence (CL) demonstrate as one plaster sample (m8), i.e., 95% anhydrite, displays a gigantic TL emission of 33 555 a.u. and a SEM/CL emission of 2319 a.u. maxima peak. The spectra CL also exhibits a 484 nm peak attributable to the classic {sup 4}F{sub 9/2}{yields}{sup 6}H{sub 15/2} transition circa 490 nm of Dy{sup 3+} and a 573 nm emission of Dy{sup 3+} masked in a ...
2008-02-15
Large-scale production of single-walled carbon nanotubes by induction thermal plasma
International Nuclear Information System (INIS)
High quality single-walled carbon nanotubes (SWNT) have been synthesized at large scales by the method of direct evaporation of carbon black and metallic catalyst mixtures, using induction thermal plasma technology. The processing system consists mainly of an RF plasma torch, which generates a plasma jet of extremely high temperature (?15 000 K), with a high energy density and abundance of reactive species (ions and neutrals). With the present reactor system, it has been demonstrated that carbon soot product which contains approximately 40 wt% of SWNT can be continuously synthesized at the high production rate of ?100 g h-1. The processing parameters involved have been examined closely in order to evaluate their individual influences on SWNT synthesis. The results have shown that the quality and purity of the SWNT produced are critically affected by the grade of carbon black, the plasma gas composition and the metallic catalyst employed. ...
2007-04-21
Initiation of ecton processes by interaction of a plasma with a microprotrusion on a metal surface
International Nuclear Information System (INIS)
Evolution of rapid (?10 ns) Ohmic overheating of a microprotrusion on a surface in contact with a plasma by emission current is studied taking into account the energy carried by plasma ions and electrons, as well as Ohmic heating, emissive source of energy release (Nottingham effect), and heat removal due to heat conduction. Plasma parameters were considered in the range of n = 1014-1020 cm-3 and Te = 0.1 eV-10 keV. The threshold value of energy transferred to the surface from the plasma is found to be 200 MW/cm2; above this value, heating becomes explosive (namely, an increase in the temperature growth rate (?2T/?t2 > 0) and in passing current (?J/?t > 0) is observed in the final stage at T ? 104 K and j ? 108 A/cm2). In spite of the fact that Ohmic heating does not play any significant role for plasmas with a density lower than 10 18 cm-3 because the current is limited by the space charge of electrons, rapid overheating of top of microprotrusion is observed ...
2008-12-01
Development of MHD generator channel walls, 1
International Nuclear Information System (INIS)
Experimental results of compatibility tests on ceramics-metal bonded structures performed under high heat flux conditions in splash test apparatus are reported. Emphasis is placed on results of the channel wall design and its critical operating conditions under MHD environment. The module design of one cold type and three semihot type insulators have been tested. These materials were Al_2O_3, Al_2MgO_4, LaAlO_4, MgO and Sialon ceramics. The methods of cold type ceramics-metal bonding structure were studied on Al_2O_3 and Spinel spray coating technology. The refractory metallizing and ceramics-metal graded structure manufactured by HIP technologies were applied to bonding between the MgO or LaAlO_4 and metallic cooling system. The Sialon non-bonding structure was tested with mechanical supported cooling system by shrinc fitting method. The results indicated that the bonding structures made of the MgO(MG-S) with Copper and Fe-Ni Alloy relaxation layers and MgO(MG-NC) ...
International Nuclear Information System (INIS)
A numerical study of a natural convection in a rectangular cavity with the low-Reynolds-number differential stress and flux model is presented. The primary emphasis of the study is placed on the investigation of the accuracy and numerical stability of the low-Reynolds-number differential stress and flux model for a natural convection problem. The turbulence model considered in the study is that developed by Peeters and Henkes (1992) and further refined by Dol and Hanjalic (2001), and this model is applied to the prediction of a natural convection in a rectangular cavity together with the two-layer model, the shear stress transport model and the time-scale bound #upsilon#"2-f model, all with an algebraic heat flux model. The computed results are compared with the experimental data commonly used for the validation of the turbulence models. It is shown that the low-Reynolds-number differential stress and flux model predicts well the mean velocity and temperature, the ...
2004-10-01
Revisited the mathematical derivation wall thickness measurement of pipe for radiography
Energy Technology Data Exchange (ETDEWEB)
Wall thickness measurement of pipe is very important of the structural integrity of the industrial plant. However, the radiography method has an advantage because the ability of penetrating the insulated pipe. This will have economic benefit for industry. Moreover, the era of digital radiography has more advantages because the speed of radiographic work, less exposure time and no chemical used for film development. Either the conventional radiography or digital radiology, the wall thickness measurement is using the tangential radiography technique (TRT). In case, of a large diameter, pipe (more than inches) the determination maximum penetration wall thickness must be taken into the consideration. This paper is revisited the mathematical derivation of the determination of wall thickness measurement based on tangential radiography technique (TRT). The mathematical approach used in this derivation is the ...
2007-07-01
Applicability of structural wall test results to seismic design of nuclear facilities
International Nuclear Information System (INIS)
A review of tests on earthquake-resistant reinforced concrete structural walls is presented. Laboratory tests of isolated walls and construction joints are discussed. Where appropriate, design recommendations are given. The review indicates only few experimental data are available for short walls which are directly applicable to nuclear power plant design. In particular, tests of short rectangular walls subjected to load reversals are needed. Tests are also needed to determine the damping and frequency characteristics of cracked short walls. Analytical and experimental results should be correlated so that the hysteretic response observed in tests can be realistically related to the analytical response 'demand' of nuclear power plant structures. (Auth.).
A task-based usage strategy for control centre wall displays
Energy Technology Data Exchange (ETDEWEB)
This paper summarizes the findings from an exploratory definition of a usage strategy for multiple control centre wall displays in CANDU nuclear power plants. Wall displays are defined as large sized, vertically oriented display surfaces that may be positioned in various locations about a control room to support user information needs. The paper begins by discussing the need for a usage strategy for all control room information resources, and then reviews the history in wall display implementation and usage in nuclear power plant control rooms. The balance of the paper discusses the approach used in characterization and review of control room task information needs and definition of a wall display usage strategy. The paper concludes by outlining some of the possible impacts on future control room design and operations that the introduction of wall displays may imply. (author)
2005-07-01
Thermal-hydraulic limitations on water-cooled limiters
Energy Technology Data Exchange (ETDEWEB)
An assessment of the cooling requirements for fusion reactor components, such as the first wall and limiter/divertor, was carried out using pressurized water as the coolant. In order to establish the coolant operating conditions, a survey of the literature on departure from nucleate boiling, critical heat flux, asymmetrical heating and heat transfer augmentation techniques was carried out. The experimental data and the empirical correlations indicate that thermal protection for the fusion reactor components based on current design concepts can be provided with an adequate margin of safety without resorting to either high coolant velocities, excessive coolant pressures, or heat transfer augmentation techniques. If, however, the future designs require heat transfer enhancement techniques, experimental verification would be necessary since no data on heat transfer augmentation techniques exist for complex geometries, especially under asymmetrically heated conditions. ...
1984-08-01
Thermal-hydraulic limitations on water-cooled fusion reactor components
Energy Technology Data Exchange (ETDEWEB)
An assessment of the cooling requirements for fusion reactor components, such as the first wall and limiter/divertor, was carried out using pressurized water as the coolant. In order to establish the coolant operating conditions, a survey of the literature on departure from nucleate boiling, critical heat flux, asymmetrical heating and heat transfer augmentation techniques was carried out. The experimental data and the empirical correlations indicate that thermal protection for the fusion reactor components based on conventional design concepts can be provided with an adequate margin of safety without resorting to either high coolant velocities, excessive coolant pressures, or heat transfer augmentation techniques. If, however, the future designs require unconventional shapes or heat transfer enhancement techniques, experimental verification would be necessary since no data on heat transfer augmentation techniques exist for complex geometries, especially under ...
1986-01-01
Thermal-hydraulic limitations on water-cooled fusion reactor components
Energy Technology Data Exchange (ETDEWEB)
An assessment of the cooling requirements for fusion reactor components, such as the first wall and limiter/divertor, was carried out using pressurized water as the coolant. In order to establish the coolant operating conditions, a survey of the literature on departure from nucleate boiling, critical heat flux, asymmetrical heating and heat transfer augmentation techniques was carried out. The experimental data and the empirical correlations indicate that thermal protection for the fusion reactor components based on conventional design concepts can be provided with an adequate margin of safety without resorting to either high coolant velocities, excessive coolant pressures, or heat transfer augmentation techniques. If, however, the future designs require unconventional shapes or heat transfer enhancement techniques, experimental verification would be necessary since no data on heat transfer augmentation techniques exist for complex geometries, especially under ...
1987-01-01
Thermal-hydraulic limitations on water-cooled fusion reactor components
International Nuclear Information System (INIS)
An assessment of the cooling requirements for fusion reactor components, such as the first wall and limiter/divertor, was carried out using pressurized water as the coolant. In order to establish the coolant operating conditions, a survey of the literature on departure from nucleate boiling, critical heat flux, asymmetrical heating and heat transfer augmentation techniques was carried out. The experimental data and the empirical correlations indicate that thermal protection for the fusion reactor components based on conventional design concepts can be provided with an adequate margin of safety without resorting to either high coolant velocities, excessive coolant pressures, or heat transfer augmentation techniques. If, however, the future designs require unconventional shapes or heat transfer enhancement techniques, experimental verification would be necessary since no data on heat transfer augmentation techniques exist for complex geometries, especially under ...
1986-12-07
Reducing indoor air formaldehyde concentrations
Energy Technology Data Exchange (ETDEWEB)
Urea-formaldehyde resin bonded particle board, medium density fiberboard and plywood paneling are used as flooring, wall paneling, for cabinet work and in furniture, and are present in almost every office, home and public building. If large quantities of these products are used in poorly ventilated spaces, high manufacturing quality control is necessary to avoid problems of latent formaldehyde release. Indoor air formaldehyde concentrations depend on the nature of the product, the product surface to air volume (loading) factor, temperature, humidity, age and product emission rates. Standard test methods are now available for measuring product emission rates that make it possible to predict the performance of UF-bonded pressed wood materials if use conditions and environmental parameters are known. Recent modifications in adhesive and board manufacturing parameters have made it possible to reduce formaldehyde emission significantly, and ...
1985-08-01
Processing method and processing facility for carbon steel parts in nuclear power plant
International Nuclear Information System (INIS)
In a closed circuit formed by bypassing pipelines connected to carbon steel parts, low oxygen coolants pass there through during operation. A solution containing ions of metals more noble than iron are circulated to bring the solution into contact with the carbon steel surface of the inner wall of the parts to form a deposition membrane of the metal more noble than iron on the surface to prevent acceleration of corrosion of the carbon steel parts due to low oxygen coolants. The solution containing ions of metals more noble than iron is a solution of palladium nitrate containing ions of platinum elements. This operation is conducted under a temperature condition of from 50degC to 150degC. In addition, the metal ion concentration of the solution circulating in the closed circuit is measured, it is compared with metal ion concentration previously determined, and the results are feed back to a means for controlling water quality of the solution to ...
1996-11-27
Energy Technology Data Exchange (ETDEWEB)
An experimental and analytical study was performed to improve understanding of the dynamic impact behavior of carbon steel pipes. The test program addressed two types of pipe impact scenarios using both 2- and 4-in. Sch-80 pipes and elbows. Projectile-on-pipe tests simulated the behavior of a stationary target pipe which is impacted at its center by a larger, more rigid whipping pipe. These target pipes, which contained non-flowing water at about 290{degree}C temperature and ca 8.5 megapascals pressure, exhibited a peak deformation of up to 45% reduction in their diameter. For each test condition, the local deformation at the impact zone is a function of the peak impact force and impact velocity. Pipe-on-wall tests simulated the impact of an elbow at the free end of a cantilevered whipping pipe with a rigid barrier. The peak crush of the impact zone of the elbows was a function of peak impact force. Numerical analyses of dynamic impact tests ...
1984-06-01
International Nuclear Information System (INIS)
A comparative assessment of five different heat transfer configurations for operation in compact heat exchangers is presented. The configurations under consideration are four standaed heat exchanger surfaces - two plain fin, an offset strip and a louvered fin geometry - and one surface with so called vortex generators for heat transfer augmentation. In the case of the standard surfaces, the basic performance characteristics in the form of heat transfer and friction data versus the Reynolds number have been taken from published experimental results. In the case of the vortex generator surface, the performance characteristics have been derived from a numerical prediction of the flow and temperature field in a closely spaced parallel plate channel with vortex generators in the form of delta wings mounted on the channel walls. In comparison to the plain fin surfaces with a rectangular cross section, the vortex generator surface shows best ...
1993-01-01
Optimal control of the free boundary in a two-phase Stefan problem
We present an optimal control approach for the solidification process of a melt in a container. The process is described by a two phase Stefan problem with the free boundary (interface between the two phases) modelled as a graph. We control the evolution of the free boundary using the temperature on the container wall. The control goal consists in tracking a prescribed evolution of the free boundary. We achieve this goal by minimizing a appropriate cost functional. The resulting minimization problem is solved numerically by a steepest descent method with step size control, where the gradient of the cost functional is expressed in terms of the adjoint variables. Several numerical examples are presented which illustrate the performance of the method. The novelty of the approach presented consists in using a sharp interface model for the control of the free boundary. This guarantees direct access to the free boundary as optimization variable in ...
2007-05-01
International Nuclear Information System (INIS)
The Nuclear Safety Commission acknowledged the policy of the Agency of Natural Resources and Energy to cope with these important matters on August 8, 1984. The main contents of the investigation and deliberation were as follows, As to the prevention of the occurrence of fires, the prevention of the leak and spread of inflammable liquid and gas, the installation of protective relays and so on, the use of incombustible materials and aseismatic design and the installation of lightning arresters. As to the detection of fires and fire fighting, the proper selection and arrangement of fire detectors and extinguishers, the extinguishers which do not harm the safety function of structures and equipment, and the extinguishers which are not affected by natural phenomena. As to the reduction of the effect of fires, the proper installation of fire walls and extinguishers, and the high temperature shut off of nuclear reactors which is never hampered by any ...
1985-01-01
International Nuclear Information System (INIS)
In the High Flux Reactor (HFR) at Grenoble a new horizontally arranged cold neutron source will be installed that uses liquid deuterium (D_2) as the moderator for cold neutrons. This cold source should provide a high neutron flux, it should be simple in design, and be characterized by high reliability and by safe operation. A high neutron flux calls for installation of the cold source near the HFR core and good moderation requires a D_2 volume of #DELTA#5 litres. Hence, the moderator, contained in a horizontally arranged cylindrical cell of 21 cm diameter and 20 cm length, is installed at the end nearest to the core of a horizontal beam tube of roughly 4.5 m length with an inner diameter of only 23 cm (Fig. 1). The HFR will be equipped with a second cold neutron source. The installation in the existing horizontal beam tube together with the amount of heat released determined the problems to be solved: the liquid content of the moderator cell must be high; the coolability of the upper ...
MTX diagnostic and timing system for free-electron laser heating experiments
International Nuclear Information System (INIS)
In the microwave tokamak experiment (MTX) program, we are concentrating on experiments using intense, free-electron laser (FEL) generated microwave pulses. In initial FEL experiments, several diagnostic instruments were operated during injection of microwave pulses with peak powers to 0.2 GW at durations of 10 ns. Fixed and spatially scanning microwave detectors and receivers and a 48-element calorimeter on the inside wall of MTX diagnosed the GW-level FEL microwave pulses. With these diagnostics, linear-wave absorption and efficiencies of transmission through the quasi-optical transport system were studied. In addition, several radially resolved measurements of plasma density, temperature, and emission were made during FEL injection and were used in the analysis of microwave absorption data. A timing system, slaved to the FEL pulse arrival time, is capable of accuracy to a few nanoseconds in order to allow measurement of heating effects on the ...
Heat transfer augmentation in the transition region and low Reynolds number turbulent flows
Energy Technology Data Exchange (ETDEWEB)
The authors report experimental results of heat transfer in the region of transition to turbulence. The augmentation was induced through deployment of periodically placed cylindrical eddy promoters in parallel plane channel flows. Eight different configurations were used. The presence of eddy promoters displaced the point of transition from Reynolds number values of 1500 for the plane channel to around 400 for the least stable case. The value of Nusselt number at the transition for eddy promoters cases was up to 2.5 times higher than the one for the plane channel at the transition. Furthermore, the lower the transition Reynolds number, the higher the Nusselt number at the transition. For the cases where the diameter of the promoters was small and/or the pitch large, the heat transfer results in the transition region were consistent with values obtained from the Reynolds analogy when the analogy was based on the mean transport parameters, i.e., spatially averaged heat transfer ...
1995-12-31
Design of the ZTH vacuum liner
Energy Technology Data Exchange (ETDEWEB)
The current status of the ZTH vacuum liner design is covered by this report. ZTH will be the first experiment to be installed in the CPRF (Confinement Physics Research Facility) at the Los Alamos National Laboratory and is scheduled to be operational at the rated current of 4 MA in 1992. The vacuum vessel has a 2.4 m major radius and a 40 cm minor radius. Operating parameters which drive the vacuum vessel mechanical design include a 300 C bakeout temperature, an armour support system capable of withstanding 25 kV, a high toroidal resistance, 1250 kPa magnetic loading, a 10 minute cycle time, and high positional accuracy with respect to the conducting shell. The vacuum vessel design features which satisfy the operating parameters are defined. The liner is constructed of Inconel 625 and has a geometry which alternates sections of thin walled bellows with rigid ribs. These composite sections span between pairs of the 16 diagnostic stations to ...
1987-01-01
Energy Technology Data Exchange (ETDEWEB)
The present invention concerns a device for peeling off activated concretes in processing for discarding a reactor of a nuclear reactor facility. The device comprises a gyrotron for generation microwaves, an irradiator for irradiating output microwaves, a reflection mirror for reflecting and converging the microwaves and irradiating them to a material to be irradiated and a first rotating means for rotating the irradiator and the reflection mirror in parallel with the axis of the gyrotron while maintaining the positional relation between the irradiator and the reflection mirror. When the position of the microwaves irradiated on concrete walls are moved in a circumferential direction and the central axes of the rotational axis and the material to be irradiated are aligned, then the intensity of the irradiation of the microwaves at each of the irradiation points can be maintained constant without changing the focal distance of the reflected microwaves thereby ...
1997-11-28
Conceptual design of the Fast-Liner Reactor (FLR) for fusion power
International Nuclear Information System (INIS)
The generation of fusion power from the Fast-Liner Reactor (FLR) concept envisages the implosion of a thin (3-mm) metallic cylinder (0.2-m radius by 0.2-m length) onto a preinjected plasma. This plasma would be heated to thermonuclear temperatures by adiabatic compression, pressure confinement would be provided by the liner inertia, and thermal insulation of the wall-confined plasma would be established by an embedded azimuthal magnetic field. A 2- to 3-mu s burn would follow the approx. 10"4 m/s radial implosion and would result in a thermonuclear yield equal to 10 to 15 times the energy initially invested into the liner kinetic energy. For implosions occurring once every 10 s a gross thermal power of 430 MWt would be generated. The results of a comprehensive systems study of both physics and technology (economics) optima are presented. Despite unresolved problems associated with both the physics and technology of the FLR, a conceptual power ...
Applications or radiation polymerization hardening to composites
International Nuclear Information System (INIS)
Comprehensive investigation has been made into the application of the polymerization hardening by radiation, particularly electron beam, to the composites of polymers and other materials. The report is divided into four parts, namely 1) characteristics and problems of the reaction of curing by radiation polymerization, 2) improvement of the bonding capability of high molecular weight materials, 3) bonding by radiation, and 4) composites made by the impregnation and polymerization hardening of monomers. The first part includes the effects of dose rate, temperature rise during the hardening, the peculiarity of electron beam irradiation at high dose rate, reaction environment and additive effects. Main conclusions are as follows: caution must be taken to the amount of residual double bonds because they affect the quality of hardened polymers; the polymerization hardening reaction at high dose rate cannot be analogized by that at low dose rate; and the presence of the ...
1976-01-01
Applications of a downhole programmable microprocessor for a geothermal borehole inspection tool
Energy Technology Data Exchange (ETDEWEB)
The high-temperature scanning borehole inspection system is currently being developed jointly by the Los Alamos National Laboratory (LANL) and Westfalische Berggewerkschaftskasse (WBK) of West Germany. The downhole instrument is a digital televiewer that utilized a microprocessor to digitize, process and transmit the acoustic information to the surface acquisition and control system. The primary operation of the downhole acoustic assembly uses a piezoelectric crystal acting as a receiver-transmitter which is mounted on the rotating head. The crystal emits a burst of acoustic energy that propagates through the borehole fluid with a portion of the energy reflected by the borehole wall back to the crystal. The time of travel and the amplitude of the reflected signal are conditioned by the microprocessor and transmitted along with other pertinent data to the surface data processing center. This instrument has been designed specifically for use in ...
1987-01-01
The Scientific Activities of CERN and Budget Estimates for the Years 1995-2005
The Scientific Activities of CERN and Budget Estimates for the Years 1995-2005
1993-01-01
Estimation of the age of the universe by the nucleochronology method
Energy Technology Data Exchange (ETDEWEB)
Unconditional estimates are suggested for the age of radioactive nuclei and hence for the age of the Universe.
1983-10-01
Estimating The Cost Of Developing Software
Software Cost Estimation Model program, SOFTCOST, developed to provide consistent automated
1991-01-01
Chemical thermodynamics of silica: a critique on its geothermometer
Energy Technology Data Exchange (ETDEWEB)
The chemical thermodynamic concepts used in the calculation of solubility data of silica (quartz) are presented taking into account the PVT characteristics of water. The temperature-dependence trends between the thermodynamically calculated and the experimental quartz solubility data are very similar, but the values are widely different at high temperatures. The experimental solubility, especially along the saturation curve at high temperature and thermodynamic data for silica need to be reevaluated in order to use silica chemistry to understand geological processes. There could exist a wide range of values for silica solubility at a specified temperature, depending upon the amount of water in the reaction vessel. Thus the silica contents in geothermal fluid, in general, cannot be used as a geothermometer to estimate the reservoir temperature. The derivation of ...
2000-06-01
International Nuclear Information System (INIS)
The ion nitriding treatment is a process widely used in steel alloys to improve the material's properties; such as surface hardness, resistance to wear, fatigue life and resistance to corrosion. But geometric changes in the components can produce during the nitriding process different effects on the behavior of the plasma, such as local variations in the electric field, an empty cathode effect, etc. These in turn can affect among other factors the local temperature and therefore the kinetics of the process, generating variations in the compound layer thicknesses and zone of diffusion, and micro-hardness profile. These heterogeneities limit the effectiveness of the plasma nitriding process, where control and duplication of the surface modification are most important. This work aims to study the effect of the geometry of the pieces treated with ionic nitriding, especially the effect of the orifices. An understanding of the operating mechanisms is sought in order to ...
2006-12-01
BEACON eSpace at Jet Propulsion Laboratory: Estimating the Cost of ...
Jan 22, 2011 ... dc.subject.other, Cost cost estimating budgets budget estimating ... dc.title, Estimating the Cost of Doing a Cost Estimate, en_US ...
Walled-off pancreatic necrosis
UK PubMed Central (United Kingdom)
Walled-off pancreatic necrosis (WOPN), formerly known as pancreatic abscess is a late complication of acute pancreatitis. It can be lethal, even though it is rare. This critical review provides an overview...Full Text Available
2010-04-14
Thermal energy considerations on solar cavity wall building
Energy Technology Data Exchange (ETDEWEB)
The dwelling is equipped with solar collectors which heat the air circulating in the cavity walls and the space beneath the floors. The thermal aspects of such a building are described. Heat balance, losses, heating by the sun in different seasons are described. Different measures taken to reduce the energy losses are described.
1983-02-01
UK PubMed Central (United Kingdom)
The fungal pathogen Candida albicans is one of the leading causative agents of death in immunocompromised individuals. It harbors an arsenal of cell wall anchored factors that are implicated...Full Text Available
2011-01-01
Sealant tests to control radon emanation in a uranium mine. Open file report sep 79-dec 81
International Nuclear Information System (INIS)
This report describes a field-test program to determine the effectiveness of a polymeric wall sealant to reduce the escape of naturally occurring radioactive gas radon from the walls of an underground uranium mine into the ventilation air.
UK PubMed Central (United Kingdom)
The objective of this study was to determine if inflammatory tolerance and enhancement of innate immune function could be induced by the gram-positive cell wall component peptidoglycan (PGN)....Full Text Available
2008-10-01
Poland's anomaly. Natural history and long-term results of chest wall reconstruction in 33 patients.
UK PubMed Central (United Kingdom)
Poland's anomaly is an uncommon congenital aberration of the chest wall characterized by absence of the pectoralis major muscle and other nearby musculoskeletal components. In this series, a wide spectrum...Full Text Available
1988-12-01
Mapping strain exerted on blood vessel walls using deuterium double-quantum-filtered MRI
UK PubMed Central (United Kingdom)
A technique is described for displaying distinct tissue layers of large blood vessel walls as well as measuring their mechanical strain. The technique is based on deuterium double-quantum-filtered (DQF)...Full Text Available
1998-04-14
UK PubMed Central (United Kingdom)
Blunt chest-wall trauma is common; however, resultant tricuspid valve rupture is rare and can be subtle in its presentation. Transthoracic echocardiography plays a key role in diagnosis.Herein,...Full Text Available
2009-01-01
UK PubMed Central (United Kingdom)
BackgroundClinical studies suggest that local wall shear stress (WSS) patterns modulate the site and the progression of atherosclerotic lesions. Computational fluid dynamics (CFD)...Full Text Available
Ewing's sarcoma: a neuroectodermal tumor of the chest wall
International Nuclear Information System (INIS)
Ewing's sarcoma is the second most common malignant bone tumor in children and young adults. It is most prevalent between the ages of 10 and 15 years. There are present two cases of Ewing's sarcoma of the chest wall. The clinical, radiological and pathological features are described and the therapeutic options are discussed. (Author)
Effects of Multivalent Cations on Cell Wall-Associated Acid Phosphatase Activity
UK PubMed Central (United Kingdom)
Primary cell walls, free from cytoplasmic contamination were prepared from corn (Zea mays L.) roots and potato (Solanum tuberosum) tubers. After EDTA treatment, the...Full Text Available
1988-09-01
UK PubMed Central (United Kingdom)
BackgroundDuring normal breathing, the mesothelial surfaces of the lung and chest wall slide relative to one another. Experimentally, the shear stresses induced by...Full Text Available
2008-10-01
A Model for Predicting Ionic Equilibrium Concentrations in Cell Walls 1
UK PubMed Central (United Kingdom)
Purified cell walls were prepared from roots of Horse bean (Vicia faba L., var. minor) and Yellow Lupine (Lupinus luteus L.). Two methods were used:...Full Text Available
1981-08-01
A General Model of the Resistive Wall Instability in Linear Accelerators
Energy Technology Data Exchange (ETDEWEB)
A general model for wakefield-generated instabilities in linear accelerators, originally developed for cumulative beam breakup [1], is applied to the resistive wall instability. The general solution for various bunch charge distributions and application to various accelerator configurations are presented.
2007-01-08
Thermal performance of phase change wallboard for residential cooling application
Energy Technology Data Exchange (ETDEWEB)
Cooling of residential California buildings contributes significantly to electrical consumption and peak power demand mainly due to very poor load factors in milder climates. Thermal mass can be utilized to reduce the peak-power demand, downsize the cooling systems, and/or switch to low-energy cooling sources. Large thermal storage devices have been used in the past to overcome the shortcomings of alternative cooling sources, or to avoid high demand charges. The manufacturing of phase change material (PCM) implemented in gypsum board, plaster or other wall-covering material, would permit the thermal storage to become part of the building structure. PCMs have two important advantages as storage media: they can offer an order-of-magnitude increase in thermal storage capacity, and their discharge is almost isothermal. This allows the storage of high amounts of energy without significantly changing the temperature of the room envelope. As heat ...
1997-04-01
Reference neutron transport calculation note for Korea nuclear power plants with 3-loop PWR reactors
Energy Technology Data Exchange (ETDEWEB)
Reactor pressure vessel (RPV) steels are subjected to neutron irradiation at a temperature of about 290 deg C. This radiation exposure alters the mechanical properties, leading to a shift of the brittle-to-ductile transition temperature toward higher temperatures and to a diminution of the rupture energy as determined by Charpy V-notch tests. This radiation embrittlement is one of the important aging factors of nuclear power plants. U.S. NRC recommended the basic requirements for the determination of the pressure vessel fluence by regulatory guide DG-1025 in order to reduce the uncertainty in the determination of neutron fluence calculation and measurements. The determination of the pressure vessel fluence is based on both calculations and measurements. The fluence prediction is made with a calculation and the measurements are used to qualify the calculational methodology. Because of the importance and the difficulty of ...
1997-05-01
International Nuclear Information System (INIS)
This paper reports about in-situ corrosion studies on selected materials for long-term resistant high-level waste (HLW) packagings acting as a barrier in a rock salt repository. The materials (Ti 99.8-Pd, Hastelloy C4 and five iron-base materials) were investigated in heated boreholes in the Asse salt mine under simulated HLW disposal conditions prevailing in normal operation of repository and in certain accident scenarios. The experiments under normal operating conditions were performed at temperatures of 120 deg. C to 210 deg. C (vertical temperature profile in the boreholes) without and with gamma irradiation (3#centre dot#10"2 Gy/h, Co-60 source) within the framework of the German/US Brine Migration Test. In these experiments only small amounts of migrated brine inclusions (NaCl-rich) from the rock salt were present as corrosion medium. In the experiments carried out under simulated accident conditions with intrusion of larger amounts of ...
1993-02-01
In this paper, we studied vapor-liquid equilibria (VLE) and adsorption of ethylene on graphitized thermal carbon black and in slit pores whose walls are composed of graphene layers. Simple models of a one-center Lennard-Jones (LJ) potential and a two-center united atom (UA)-LJ potential are investigated to study the impact of the choice of potential models in the description of VLE and adsorption behavior. Here, we used a Monte Carlo simulation method with grand canonical Monte Carlo (GCMC) and Gibbs ensemble Monte Carlo ensembles. The one-center potential model cannot describe adequately the VLE over the practical range of temperature from the triple point to the critical point. On the other hand, the two-center potential model (Wick et al. J. Phys. Chem. B 2000, 104, 8008-8016) performs well in the description of VLE (saturated vapor and liquid densities and vapor pressure) over the wide range of temperature. This UA-LJ ...
2004-08-17
Single-Walled Carbon Nanotubes Targeted to the Tumor ...
... 1981. Retention of diphenyls, terphenyls, phenylalkanes and fluorene on graphitized thermal carbon black. Chromatographia 14:510-514. ...
2009-09-01
Physical and Computational Investigation of the Wall Pressure ...
... Although other authors had made cross-spectral density measurements, Corcos pointed to the importance of this function as indicative of the true ...
1990-04-26
Vibration characteristics of SMA composite beams with different boundary conditions
Energy Technology Data Exchange (ETDEWEB)
Recently, the development of shape memory alloy (SMA) actuators, in the forms of wire, thin film and stent have been found increasingly in the fields of materials science and smart structures and engineering. The increase in attraction for using these materials is due to their many unique materials, mechanical, thermal and thermal-mechanical properties, which in turn, evolve their subsequent shape memory, pseudo-elasticity and super-elasticity properties. In this paper, a common type of SMA actuator, Nitinol wires, were embedded into advanced composite structures to modulate the structural dynamic responses, in terms of natural frequency and damping ratio by using its shape memory and pseudo-elastic properties. A simple theoretical model is introduced to estimate the natural frequency of the structures before and after actuating the embedded SMA wires. The damping ratios of different SMA composite beams were measured through experimental approaches. The natural ...
2002-12-15
International Nuclear Information System (INIS)
The RESF is utilized for storage of spent fuel under emergency conditions as well as for testing of FM heads. It receives cooling supply from the PHT Pressurizing pumps and after removal of decay heat from the spent fuel it goes to the D2O Storage Tank. The geometry of the RESF system is such that it can not sustain the thermosyphon loop during SBO, due to high frictional forces. To achieve the sustained thermosyphon, modifications in the design were suggested viz., removal of the steam trap and the relief valve above it and replacement by a solenoid valve (SV-16). In the event of SBO, SV-16 will open on 'RESF channel temperature high' signal and connect to FT D2O tank. The tank, being at atmospheric pressure and at lower elevation, will provide higher cooling flow rate through the RESF channel. D2O is periodically removed from the FT D2O tank by operating a Class-II pump intermittently. The analysis was done for the modified RESF system configuration to ...
2006-11-13
Spin-lattice relaxation in A-15 type intermetallic compounds
Energy Technology Data Exchange (ETDEWEB)
The temperature dependence of T/sub 1/ spin-lattice relaxation time on /sup 51/V, /sup 69/Ga, /sup 71/Ga and Knight shift on /sup 51/V and /sup 29/Si nuclei in polycrystalline V/sub 3/Si, V/sub 3/Ga, V/sub 3/Ge and in the monocrystal V/sub 3/Si in normal state is investigated. For V/sub 3/Si and V/sub 3/Ga a rapid growth (T/sub 1/T)/sup -1/ is observed with temperature decrease while for V/sub 3/Ge the maximum (T/sub 1/T)/sup -1/ at T approximately equal to 60 K has been found. The temperature dependence peculiarities have been discussed on the basis of theoretical models available and zone structure calculations for A-15 compounds. The T/sub 1/ anisotropy and possibility of its experimental discovery are considered. Anisotropic contribution in (T/sub 1/T)/sup -1/ and contributions of d states of different symmetries into the electron state density at the Fermi level are estimated for V/sub 3/Si from ...
1981-04-01
Spin-lattice relaxation in A-15 type intermetallic compounds
International Nuclear Information System (INIS)
The temperature dependence of T_1 spin-lattice relaxation time on "5"1V, "6"9Ga, "7"1Ga and Knight shift on "5"1V and "2"9Si nuclei in polycrystalline V_3Si, V_3Ga, V_3Ge and in the monocrystal V_3Si in normal state is investigated. For V_3Si and V_3Ga a rapid growth (T_1T)"-"1 is observed with temperature decrease while for V_3Ge the maximum (T_1T)"-"1 at T approximately equal to 60 K has been found. The temperature dependence peculiarities have been discussed on the basis of theoretical models available and zone structure calculations for A-15 compounds. The T_1 anisotropy and possibility of its experimental discovery are considered. Anisotropic contribution in (T_1T)"-"1 and contributions of d states of different symmetries into the electron state density at the Fermi level are estimated for V_3Si from T_1 measurements.
International Nuclear Information System (INIS)
Purpose: To permit accurate detection of sodium leakage by distinguishing between variations in the overflow tank level due to changes in sodium temperature accompanying changes in the power level or operating state of a liquid metal sodium cooled fast breeder, and a reduction in power level due to duct leakage. Constitution: The volume of sodium in the primary cooling system is roughly estimated from the temperatures of hot and cold legs, and the duct leak preset level with respect to the sodium liquid level within an overflow tank when the plant is normal is varied according to the state of the plant. More particularly, the volume of sodium within the overflow tank is calculated on the basis of a signal representing the liquid level detected by a liquid level gauge in the overflow tank and a signal representing the temperature detected by hot leg and cold leg thermometers, thereby obtaining the preset ...
Energy Technology Data Exchange (ETDEWEB)
Previous analyses of binary cycles for conversion of geothermal energy from moderate temperature resources to electrical energy have shown potential gains in net geofluid effectiveness on the order of 8%, resulting from selection of turbine-expansion processes whose equilibrium states pass through the two-phase region. If condensation occurs, this gain could be reduced or eliminated by the resulting loss in turbine efficiency. Experience with many fluids, however, indicates that vapor supersaturation permits metastable pure-vapor states to exist at temperatures considerably below the saturation temperature at a given pressure; thus, by better understanding the condensation process, and properly structuring the cycle, substantial performance gains may be possible. The purpose of the present study was to assess the probability for attaining this performance gain by estimating the extent of condensation ...
1983-01-01
Measured impact of neighborhood tree cover on microclimate
Energy Technology Data Exchange (ETDEWEB)
In this paper we present results of our investigation into the relationship between urban microclimate and the local density of tree cover as measured in Sacramento, California. These results were obtained through analysis of data collected in a two-month long monitoring program with automatic weather stations installed at 15 residential locations throughout the city. Measured wind speeds showed a highly negative correlation with respect to tree cover. Daily peak air temperatures showed significant variation often differing from site to site by 2 to 4{degrees}C ({approx}3.5 to 7{degrees}F). A complex interaction between several competing factors is discussed leading to the conclusion that additional tree cover may actually increase urban air temperatures on synoptically cool days. It is suggested that this does not have a significant adverse affect in terms of overall summer urban cooling load. This is supported by an integrated analysis of the ...
1992-08-01
International Nuclear Information System (INIS)
A laminated material composed of glass cloth/polyimide film/epoxy resin will be used as an insulating material for superconducting coil of International Thermonuclear Experimental Reactor (ITER). In order to keep safe and stable operation of the superconducting coil system, it is indispensable to evaluate radiation resistance of the material, because the material is exposed to severe environments such as high radiation field and low temperature of 4 K. Especially, it is important to estimate the amount of gases evolved from the insulating material by irradiation, because the gases affect on the purifying system of liquid helium in the superconducting coil system. In this work, the gas evolution from the laminated material by gamma ray irradiation at liquid nitrogen temperature (77 K) was investigated, and the difference of gas evolution behavior due to difference of composition in the epoxy resin was discussed. It was found ...
2008-03-03
Energy Technology Data Exchange (ETDEWEB)
In the development of the specific mathematical modeling for heavy and ultra heavy petroleum fractions in a molecular distiller is very important the definition of physical and chemical parameters as density and specific heat of the mixture, the enthalpy of vaporization, among others, since they are used in the energy balance. Information on these properties and their variation with temperature are found in the open literature for mixture with few components (simple mixtures). However, for multicomponent solutions consisting of complex mixtures such as oil and its heavy and ultraheavy fractions, available data are few, or are limited to low temperatures. The specific heat is an important property in the energy balance. This property can be measured by Differential Scanning Calorimetry (DSC), which gives results with great sensitivity and accuracy. This paper presents the variation of specific heat with the temperature of ...
2008-07-01
Energy Technology Data Exchange (ETDEWEB)
The feasibility of using hydrogen as the sole fuel in a direct injection diesel engine was investigated. An air cooled single cylinder Lister ST1 diesel engine was modified to operate as a low-heat-rejection engine for this study. Partially stabilized zirconia ceramic parts were used to shield the combustion space of the engine. Using a compression ratio of 17.9:1 and motoring the test engine at 21000 rpm, a maximum compression temperature of approximately 900 K was achieved. Under these operating conditions, all lubricants tested were found to burn. Lowering the speed to 1450 rpm and the compression ratio to 17.1, lubricant combustion and hot spots were successfully eliminated. The maximum compression temperature, when compression ignition of hydrogen was tried, was in the 800 K range. The corresponding ceramic surface temperature was estimated to reach 600-700 K. Only sporadic compression ignition of ...
1990-01-01
Low-Cost Hydrogen Distributed Production System Development
H{sub 2}Gen, with the support of the Department of Energy, successfully designed, built and field-tested two steam methane reformers with 578 kg/day capacity, which has now become a standard commercial product serving customers in the specialty metals and PV manufacturing businesses. We demonstrated that this reformer/PSA system, when combined with compression, storage and dispensing (CSD) equipment could produce hydrogen that is already cost-competitive with gasoline per mile driven in a conventional (non-hybrid) vehicle. We further showed that mass producing this 578 kg/day system in quantities of just 100 units would reduce hydrogen cost per mile approximately 13% below the cost of untaxed gasoline per mile used in a hybrid electric vehicle. If mass produced in quantities of 500 units, hydrogen cost per mile in a FCEV would be 20% below the cost of untaxed gasoline in an HEV in the 2015-2020 time period using EIA fuel cost projections for natural gas and untaxed gasoline, and 45% ...
2011-03-10
Unsteady flow of an incompressible fluid in a horizontal porous medium with suction
International Nuclear Information System (INIS)
A theoretical analysis of two-dimensional unsteady flow in a porous medium bounded by a horizontal wall is presented as a perturbation on a basic flow. It is assumed that the perturbation is occasioned by a sudden suction at the wall. Even for a highly permeable medium the characteristic Reynolds number in porous media flow is usually small and asymptotic solutions are developed by the Laplace transform technique. It is observed that the perturbed shear stress at the wall decays exponentially with time. (author). 5 refs.
2000-03-01
Energy Technology Data Exchange (ETDEWEB)
Results of an investigation made to develop methods of making iron castings having wall thicknesses as small as 2.5 mm in green sand molds are presented. It was found that thin wall ductile and compacted graphite iron castings can be made and have properties consistent with heavier castings. Green sand molding variables that affect casting dimensions were also identified.
2001-10-31
Survey of naturally radioactive level of some new type wall materials
International Nuclear Information System (INIS)
Naturally occurring radioactive materials (NORM) in seven new type wall materials were surveyed. The radioactivity was determined with HPGe-#gamma# spectrometer. The red mud has the highest radioactivity concentration, followed by slag building blocks, fly-ash building blocks (bricks), gangue bricks and light weight board materials, gypsum blocks. Fly-ash and slag contain higher NORM, which contributes the major part of the radioactivity in new wall materials. (authors)
2006-09-01
Polymer depletion-induced slip near an interface
Energy Technology Data Exchange (ETDEWEB)
A quantitative description is proposed for the depletion-induced slip thickness and velocity profile of a polymer solution near the wall-fluid interface in simple shear flow. The inhomogeneous polymer density profile at a flat wall is inserted into the equations of motion for the flow of a polymer solution near the flat wall. The theory is in quantitative agreement with simulation results. (letter to the editor)
2005-01-19
Modelling of the wall jet in a direct injection diesel engine
Energy Technology Data Exchange (ETDEWEB)
As a part of a phenomenological model, a method for simulating the wall/jet interaction in a direct injection diesel engine is proposed. The method is based on the application of the momentum conservation equation in the different directions in which the wall jet is spread, and takes into account both the interaction with the combustion chamber geometry and with swirl. It takes as initial conditions the results of calculating the free jet, which is divided into packages. The predictions provide good agreement with those by other researchers. (author).
1992-01-01
A device for assemblying a support string for an offshore drilling rig
Energy Technology Data Exchange (ETDEWEB)
The purpose of the invention is to simplify assembly and to reduce labor intensity. This is achieved by the fact that the assembly shaft is positioned in a hawser, while its wall which is turned towards the body of the installation is combined with the hawser wall, where a U shaped opening is made in the wall of the assembly shaft, along the edges of which there is a hermetically sealing device, while the bottom of the body of the offshore drilling rig is equipped with a rigid insert attached with the capability of adjoining it with the hermetically sealing device.
1983-01-01
ADVANCED UNDERGROUND GAS STORAGE CONCEPTS REFRIGERATED-MINED CAVERN STORAGE
Energy Technology Data Exchange (ETDEWEB)
Limited demand and high cost has prevented the construction of hard rock caverns in this country for a number of years. The storage of natural gas in mined caverns may prove technically feasible if the geology of the targeted market area is suitable; and economically feasible if the cost and convenience of service is competitive with alternative available storage methods for peak supply requirements. It is believed that mined cavern storage can provide the advantages of high delivery rates and multiple fill-withdrawal cycles in areas where salt cavern storage is not possible. In this research project, PB-KBB merged advanced mining technologies and gas refrigeration techniques to develop conceptual designs and cost estimates to demonstrate the commercialization potential of the storage of refrigerated natural gas in hard rock caverns. Five regions of the U.S.A. were studied for underground storage development and PB-KBB reviewed the literature to determine if the ...
1998-09-01
UNSAT-H Version 3.0: Unsaturated Soil Water and Heat Flow Model Theory, User Manual, and Examples
Energy Technology Data Exchange (ETDEWEB)
The UNSAT-H model was developed at Pacific Northwest National Laboratory (PNNL) to assess the water dynamics of arid sites and, in particular, estimate recharge fluxes for scenarios pertinent to waste disposal facilities. During the last 4 years, the UNSAT-H model received support from the Immobilized Waste Program (IWP) of the Hanford Site's River Protection Project. This program is designing and assessing the performance of on-site disposal facilities to receive radioactive wastes that are currently stored in single- and double-shell tanks at the Hanford Site (LMHC 1999). The IWP is interested in estimates of recharge rates for current conditions and long-term scenarios involving the vadose zone disposal of tank wastes. Simulation modeling with UNSAT-H is one of the methods being used to provide those estimates (e.g., Rockhold et al. 1995; Fayer et al. 1999). To achieve the above goals for assessing water ...
2000-06-12
ASTEC and MELCOR comparison for a VVER-1000 60 mm small break LOCA
International Nuclear Information System (INIS)
In this paper a comparison between severe accident calculations performed for a WWER 1000 with the ASTEC1.1v0 and MELCOR 1.8.5 computer codes for a small break LOCA (ID 60 mm) without intervention of hydro accumulators is presented. This investigation has been performed in the framework of the SARNET project under the EURATOM 6th framework program. Once the accident sequence scenario is specified, both codes (MELCORE and ASTEC) are able to determine the core and containment damaged states, to estimate the release of radionuclides from the fuel as well as from the primary circuit and containment. Theses results are used to estimate the maximum period of the time during which the personnel could still take particular decisions in order to mitigate such an accident. The aim of the performed analysis is to estimate the discrepancy between ASTEC and MELCORE 1.8.5 calculations. Such discrepancies will be studied, if the case, ...
2005-06-08
Temperature dependence of the performance of ultraviolet detectors
Energy Technology Data Exchange (ETDEWEB)
We present the results of a comprehensive study of the temperature dependences of the quantum efficiency for ultraviolet detectors based on GaAs, GaP and 4H--SiC Schottky structures, and on Si, GaAs p-n structures. For ultraviolet detectors based on Schottky structures, the quantum efficiency increases with increasing temperature for all photon energies, even including the semiconductor intrinsic absorption region. On the other hand, for ultraviolet detectors based on p-n structures, the quantum efficiency is practically temperature independent in the semiconductor intrinsic absorption region. The change in the quantum efficiency for the GaAs and Si detectors is less than 0.01% per degree. To explain the measurements, a variable trap occupancy model is presented. Subsurface imperfections of the semiconductor cause fluctuations in the profile of the conduction band and the valence band edges. In the presence of an electric ...
2003-08-21
Temperature dependence of the performance of ultraviolet detectors
International Nuclear Information System (INIS)
We present the results of a comprehensive study of the temperature dependences of the quantum efficiency for ultraviolet detectors based on GaAs, GaP and 4H--SiC Schottky structures, and on Si, GaAs p-n structures. For ultraviolet detectors based on Schottky structures, the quantum efficiency increases with increasing temperature for all photon energies, even including the semiconductor intrinsic absorption region. On the other hand, for ultraviolet detectors based on p-n structures, the quantum efficiency is practically temperature independent in the semiconductor intrinsic absorption region. The change in the quantum efficiency for the GaAs and Si detectors is less than 0.01% per degree. To explain the measurements, a variable trap occupancy model is presented. Subsurface imperfections of the semiconductor cause fluctuations in the profile of the conduction band and the valence band edges. In the presence of an electric ...
2003-08-21
Ground- and space-based temperature and humidity retrievals: Statistical evaluation
Energy Technology Data Exchange (ETDEWEB)
A near-real-time integrated temperature and water vapor sounding system has been designed and in operation since June 1993. It combines hourly data from the ground-based radio acoustic sounding system (RASS), a two-channel microwave radiometer, standard surface meteorological instruments, a lidar ceilometer, and the Aerodynamic Research Incorporated Communication, Addressing and Reporting System aboard commercial airlines with space-based data from the TIROS-N Operational Vertical Sounder (TOVS). The physical retrieval algorithm provided by the International TOVS Processing Package is used for combining the ground- and space-based temperature and humidity profiles. The first-guess profiles of temperature and humidity required by the physical retrieval algorithm are obtained by using a statistical inversion technique and the ground-based remote sensors measurements. Statistical error estimates are ...
1996-03-01
International Nuclear Information System (INIS)
Proton-conducting solid oxide fuel cells, incorporating BaZr0.1Ce0.7Y0.2O3-? (BZCY) electrolyte, NiO-BZCY anode, and Sm0.5Sr0.5CoO3-?-Ce0.8Sm0.2O2-? (SSC-SDC) cathode, were successfully fabricated by a combined co-pressing and printing technique after a one-step co-firing process at 1100, 1150, or 1200 oC. Scanning electron microscope (SEM) results revealed that the co-firing temperature significantly affected not only the density of the electrolyte membrane but the grain size and porosity of the electrodes. Influences of the co-firing temperature on the electrochemical performances of the single cells were also studied in detail. Using wet hydrogen (2% H2O) as the fuel and static air as the oxidant, the cell co-fired at 1150 oC showed the highest maximum power density (PDmax) of 552 and 370 mW cm-2 at 700 and 650 oC, respectively, while the one co-fired at 1100 oC showed the highest PDmax of 276 and 170 mWcm-2 at 600 and 550 oC, respectively. ...
2011-01-01
Constitutive modeling of a nickel base superalloy -with a focus on gas turbine applications
Energy Technology Data Exchange (ETDEWEB)
Gas turbines are used where large amounts of energy is needed, typically as engines in aircraft, ferries and power plants. From an efficiency point of view it is desirable to increase the service temperature as much as possible. One of the limiting factors is then the maximum allowable metal temperatures in the turbine stages, primarily in the blades of the first stage, that are exposed to the highest gas temperatures. Specially designed materials are used to cope with these severe conditions, such as the nickel base superalloy IN792. In order to be able to design the components for higher temperatures and tighter tolerances, a detailed understanding and computationel models of the material behaviour is needed. The models presented in this work have been developed with the objective of being physically well motivated, and with the intention of avoiding excessive numbers of parameters. The influence of ...
2003-05-01
Dispersoid separation method and apparatus
Energy Technology Data Exchange (ETDEWEB)
Improved separation of heavier material from a dispersoid of gas and heavier material entrained therein is taught by the method of this invention which advantageously uses apparatus embodied in an inertial separator having rotary partition means comprising wall members dividing a housing into a plurality of axially-extending through passages arranged in parallel. Simultaneously with the helical transit of a moving stream of the dispersoid through the parallel arrangement of axially-extending through passages at a constant angular velocity, the heavier material is driven radially to the collecting surfaces of the rotational wall members where it is collected while the wall members are rotating at the same angular velocity as the moving stream. The plurality of wall members not only provides an increased area of collecting surfaces but the positioning of each of the wall members ...
1980-01-01
British Library Electronic Table of Contents (United Kingdom)
Following Hurricane Katrina, the study of cantilevered sheet pile I-wall with gap or partial gap has become one of the central elements of the ongoing investigation pertaining to the re-building of hurricane protection systems in New Orleans, LA. Historically, the US Army Corps of Engineers (USACE) had mostly relied upon the Method of Planes (MOP) analysis procedure for slope stability analysis of I-wall systems. However MOP is a simplified procedure which does not satisfy total equilibrium. Nevertheless, MOP is still considered by USACE as a popular analysis tool because of its simplicity and ease of use in slope stability analysis. This paper demonstrates the applicability and suitability of MOP as a viable analysis tool for the analysis of New Orleans I-wall founded on layered cohesive ...
2011-01-01
Study of the thermodynamic properties of (U,Ce)O{sub 2}
Energy Technology Data Exchange (ETDEWEB)
The X-ray diffraction analysis of (U,Ce)O{sub 2} with the CeO{sub 2} contents ranging from 0 to 20 mol% CeO{sub 2} was performed at room temperature to obtain the variation in the lattice parameter with the CeO{sub 2} content. Ultrasonic pulse echo measurements were also carried out to estimate the change in the mechanical properties of (U,Ce)O{sub 2} with the CeO{sub 2} content. The lattice parameter of (U,Ce)O{sub 2} was found to decrease with increasing CeO{sub 2} content. The variation in the lattice parameter with the CeO{sub 2} content closely followed the Vegard law. The shear and longitudinal velocities in (U,Ce)O{sub 2} were found to decrease with increasing CeO{sub 2} content. The Young`s and shear moduli, and Poisson`s ratio estimated from the wave velocities decreased with the CeO{sub 2} content. No mechanical property showed anomaly in low CeO{sub 2} content region. (orig.).
1997-08-01
Energy Technology Data Exchange (ETDEWEB)
This paper reports the study results on the standard weather data necessary for simulation of PV power generation systems in fiscal 1994. In the study on the selection criterion of the standard weather data from the viewpoint of PV power generation systems, three typical years are used; a year with average solar radiation, and two years with extremely less and more solar radiation for safe simulation. The standard weather data are arranged for output calculation of PV power generation systems by selecting the most typical year based on long-term observation data. The data to be arranged are as follows; total, direct and scattered solar radiations incident upon a horizontal surface, solar radiation upon a slope surface, sunshine duration, air temperature, wind direction, wind velocity, amount of precipitation, and snow depth. For arrangement of the nationwide standard weather data, estimation of total solar radiation is necessary based on ...
1994-12-01
International Nuclear Information System (INIS)
The static thermodynamic properties of the molten salt system like LiF-NaF-BeF_2 influence the design and construction of the fuel salt and coolant in the Molten Salt Reactor for the new generation. In this paper, the equation of state of the ternary system 15%LiF-58%NaF-27%BeF_2, over the temperature range of 873.15K to 1073.15K at one atmosphere pressure, is described using Peng-Robinson equation modified by us. And the density of the ternary system is evaluated by this equation directly, and compared with the experimental data. Base on the equation of state, the other static thermodynamic properties such as the enthalpy, entropy and heat capacity at constant pressure are estimated by the residual function method and the fugacity coefficient method respectively. The density calculated by Peng-Robinson equation is in highly agreement with the experimental data, and the enthalpy, entropy and heat capacity evaluated by such two different methods ...
2007-04-22
Estimation of vapour pressure over MOX fuel
International Nuclear Information System (INIS)
Use of high plutonia MOX as fuel is contemplated from the point of view of rapid disposition of plutonium and economic power generation. The fuel pellets are subjected to steep thermal gradients #approx# 1700 K drop across a radius of #approx# 2.5mm. This leads to evaporation-condensation of the fuel constituents to cooler regions. Vaporization depends on fuel compositions such as Pu fraction, Oxygen-to-Metal (O/M) ratio and local temperature. Knowledge of vapour chemistry is essential in understanding the fuel behavior. The vaporization behaviour of MOX was analyzed in this work using thermochemical methods. The vapour phase consisted of nine species; O, O_2, Pu, PuO, PuO_2, U, UO, UO_2 and UO_3. Oxygen formed part of the vapour phase along with other species and oxygen potential was not controlled independently. The vapour pressures were estimated at 2000 K as a function of (O/M) for several Pu-fraction. Results for MOX-28%PuO_2 is shown in ...
2010-12-01
CFD Application to the Regulatory Assessment of FAC-Caused CANDU Feeder Pipe Wall Thinning Issue
Energy Technology Data Exchange (ETDEWEB)
From the results of the In-Service Inspection (ISI) measuring the wall thickness of outlet (hot-leg side) feeder pipes performed at two Canadian nuclear power plants, Point Lepreau and Gentilly-2 in 1995 and 1996, respectively, the wall thinning degradation of feeder pipes at the bend part was found to be much more severe than expected. It has been well known that such wall thinning of feeder pipes is caused by the flow accelerated corrosion (FAC) which is one of the mechanical-chemical degradation mechanisms affecting the integrity of piping systems. For the Wolsung unit 1, the wall thickness measurements have been performed during every overhaul period since 1996. The wall thinning rates at the bends of outlet feeder pipes were assessed to exceed the design value. However, for the Wolsung units 2, 3 and 4, the wall thinning rates of all the outlet feeder pipes ...
2007-07-01
CFD Application to the Regulatory Assessment of FAC-Caused CANDU Feeder Pipe Wall Thinning Issue
International Nuclear Information System (INIS)
From the results of the In-Service Inspection (ISI) measuring the wall thickness of outlet (hot-leg side) feeder pipes performed at two Canadian nuclear power plants, Point Lepreau and Gentilly-2 in 1995 and 1996, respectively, the wall thinning degradation of feeder pipes at the bend part was found to be much more severe than expected. It has been well known that such wall thinning of feeder pipes is caused by the flow accelerated corrosion (FAC) which is one of the mechanical-chemical degradation mechanisms affecting the integrity of piping systems. For the Wolsung unit 1, the wall thickness measurements have been performed during every overhaul period since 1996. The wall thinning rates at the bends of outlet feeder pipes were assessed to exceed the design value. However, for the Wolsung units 2, 3 and 4, the wall thinning rates of all the outlet feeder pipes ...
2007-05-10
Energy Technology Data Exchange (ETDEWEB)
Crop water demand in the Okanagan Basin was determined for 1961 to 1990, 2010 to 2039, 2040 to 2069, and 2070 to 2099. Daily station temperature data were spatially interpolated to a 1 x 1 km grid and adjusted for elevation. Daily precipitation data were estimated across four climatic regions. Output from three global climate models (GCM), CGCM2, CSIROMk2 and HadCM3 was used to create future daily climate. Daily potential evapo-transpiration (grass reference) was estimated from an empirical relationship between Bellani-plate atmometer readings, temperature and extra-terrestrial solar radiation, and then modified by crop coefficients for all crops except pasture. Depending on GCM, projected water demand increased by 12-20% (2010 to 2039), 24-38% (2040 to 2069) and 40-61% (2070 to 2099). Possible elevated CO{sub 2} effects on stomatal conductance which may reduce water demand were not accounted for. ...
2006-11-15
Energy Technology Data Exchange (ETDEWEB)
The Siberian Altai covers about 70% of the area of all south Siberian glaciers, which provide fresh water to the upper tributaries of the Ob and Yenisey rivers. The observed air temperature has increased by 1.2 deg. C over northern Eurasia during the last 120 years, affecting the degradation of the Siberian Altai glaciers. In this study, we estimated glacier area changes in the Aktru River basin (44.8 km{sup 2}), located in the central Altai mountains. We used the 1952, 1966, 1975 and 2006 remote sensed images with 0.6-3.0 m spatial resolution (aerial photographs, Corona and PRISM satellite images) and differential GPS (DGPS) data. From 1952 to 2006, the total glacier area in the Aktru basin shrank by 7.2% (1.2 km{sup 2}). During the last three decades, the rate of glacier area loss increased by a factor of 1.8, thus resembling trends in other mountain systems of Eurasia (Alps, Tien Shan). The glacier area changes were caused mainly by increase ...
2007-10-15
International Nuclear Information System (INIS)
The Siberian Altai covers about 70% of the area of all south Siberian glaciers, which provide fresh water to the upper tributaries of the Ob and Yenisey rivers. The observed air temperature has increased by 1.2 deg. C over northern Eurasia during the last 120 years, affecting the degradation of the Siberian Altai glaciers. In this study, we estimated glacier area changes in the Aktru River basin (44.8 km"2), located in the central Altai mountains. We used the 1952, 1966, 1975 and 2006 remote sensed images with 0.6-3.0 m spatial resolution (aerial photographs, Corona and PRISM satellite images) and differential GPS (DGPS) data. From 1952 to 2006, the total glacier area in the Aktru basin shrank by 7.2% (1.2 km"2). During the last three decades, the rate of glacier area loss increased by a factor of 1.8, thus resembling trends in other mountain systems of Eurasia (Alps, Tien Shan). The glacier area changes were caused mainly by increase of summer ...
Energy Technology Data Exchange (ETDEWEB)
A number of binary geothermal cycles utilizing mixed hydrocarbon working fluids were analyzed with the overall objective of finding a working fluid which can produce low-cost electrical energy using a moderately low temperature geothermal resource. Both boiling and supercritical shell-and-tube cycles were considered. The performance of a dual-boiling isobutane cycle supplied by a 280/sup 0/F hydrothermal resource (corresponding to the 5MW pilot plant at the Raft River site in Idaho) was selected as a reference. To investigate the effect of resource temperature on the choice of working fluid, several analyses were conducted for a 360/sup 0/F hydrothermal resource, which is representative of the Heber resource in California. The hydrocarbon working fluids analyzed included methane, ethane, propane, isobutane, isopentane, hexane, heptane, and mixtures of those pure hydrocarbons. For comparison, two fluorocarbon refrigerants were also analyzed. ...
1981-01-01
Volume 1 Cost Estimating - Cost Analysis Division - NASA
2.1 The Importance of Life Cycle Management and Cost Estimating................. ........... 1-2 .... 4.3.5 Task 12: Update Cost Estimate on Regular Basis. ...
Transaction Cost Economics (TCE) and Cost Estimation ...
... (TCE) and Cost Estimation Methodology ... 4. TITLE AND SUBTITLE Transaction Cost Economics (TCE) and Cost Estimation Methodology 5a. ...
2008-05-15
A User's Manual for Developing Cost Estimating ... - GLTRS - NASA
A collection of cost estimating relationships (CER's) and their proprietary database sources. The cost estimating relationships can be used in the aerospace ...
Energy Technology Data Exchange (ETDEWEB)
In this thesis, increased hemicellulose retention during kraft pulping has been studied. The work has been divided into three parts: i) Development of an accessible and reliable method for determination of carbohydrate composition of kraft pulps ii) Investigation of the composition and molecular mass distributions of the carbohydrates in kraft pulps with increased hemicellulose content iii) Investigation of the effect of increased hemicellulose content on the sheet properties of kraft pulps with increased hemicellulose content. A method for carbohydrate determination was developed. In this method, enzymes are used to hydrolyse the pulp into monosaccharides. A relatively mild acid hydrolysis is performed prior to detection on an HPLC with an RI-detector. The pulp is not derivatized and no pre-treatment (mechanical or chemical) is needed to determine the carbohydrate composition using the method developed here. Peak deconvolution software is used to improve the accuracy. Polysulphide and ...
2008-07-01
The economic geology of clays/shales raw materials for the ceramics industry in Lebanon
International Nuclear Information System (INIS)
Author.Field, laboratory and market studies are a must for proper evaluation of natural resources for the mineral industry of lebanon. Sites selectively convenient to the existing major Lebanese ceramics industry centered in the Beqa'a region, were investigated as to their geology, geography and economic character. The raw materials are shales, mud stones, siltstones and other argillaceous rocks of Jurassic to Cretaceous age coming from selective sites in south and central Lebanon. The finished products include wall, floor, roofing tiles, pipes, sanitary ware, pottery and brick specimens. Differential thermal analysis, scanning electron microscopy, firing and physico-chemical tests and analyses characterized the raw materials into two major groups: the suitable are siliceous argillaceous rocks and unsuitable calcareous argillaceous rocks. The suitable group is divided into two varieties. The first is dominantly a disordered Kaolinite with low drying and firing ...
Energy Technology Data Exchange (ETDEWEB)
The liquefaction reaction system of an NEDOL process coal liquefaction 1t/d PSU was opened and checked to investigate the cause of the rise of differential pressure between liquefaction reactors of the PSU. The liquefaction test at a coal concentration of 50 wt% using Tanito Harum coal was conducted, and it was found that the differential pressure between reactors was on the increase. By the two-phase flow pressure loss method, deposition thickness of deposit in pipelines was estimated at 4.4mm at the time of end operation, which agreed with a measuring value obtained from a {gamma} ray. The rise of differential pressure was caused by deposit formation in pipelines connecting reactors. The main component of the deposit is calcite (CaCO3 60-70%) and is the same as the usual one. It is also the same type as the deposit on the reactor wall. Ca in coal ash is concerned with this. To withdraw solid matters deposited in the reactor, there are ...
1996-10-28
FLUTAN 2.0. Input specifications
Energy Technology Data Exchange (ETDEWEB)
FLUTAN is a highly vectorized computer code for 3D fluiddynamic and thermal-hydraulic analyses in Cartesian or cylinder coordinates. It is related to the family of COMMIX codes originally developed at Argonne National Laboratory, USA, and particularly to COMMIX-1A and COMMIX-1B, which were made available to FZK in the frame of cooperation contracts within the fast reactor safety field. FLUTAN 2.0 is an improved version of the FLUTAN code released in 1992. It offers some additional innovations, e.g. the QUICK-LECUSSO-FRAM techniques for reducing numerical diffusion in the k-{epsilon} turbulence model equations; a higher sophisticated wall model for specifying a mass flow outside the surface walls together with its flow path and its associated inlet and outlet flow temperatures; and a revised and upgraded pressure boundary condition to fully include the outlet cells in the solution process of the conservation equations. Last ...
1996-05-01
Energy Technology Data Exchange (ETDEWEB)
The growth of stoichiometric and non-stoichiometric silicon nitride films was studied experimentally on 100 mm silicon wafers by batch depositions from the dichlorosilane (SiH{sub 2}Cl{sub 2})-ammonia (NH{sub 3}) system in a hot-wall horizontal low pressure chemical vapor deposition (LPCVD) reactor. The growth kinetics were discussed in terms of the Langmuir adsorption isotherm. The kinetic parameters were determined by comparing the experimental data with a one-dimensional simulation model. The decomposition of NH{sub 3} at high temperatures was included in the simulation procedure. When the SiH{sub 2}Cl{sub 2}:NH{sub 3} ratios were greater than 1.5, a quantity higher than the thermodynamic critical values above which Si-rich nitride films begin to deposit, various SiN{sub x} films with x < 4/3 were obtained. The composition of the SiN{sub x} films was found to vary along the LPCVD reactor. The film stoichiometry was examined by Rutherford ...
1992-06-15
Energy Technology Data Exchange (ETDEWEB)
The Coal Fired Combined Cycle (CFCC) power system thermodynamic cycle is illustrated schematically. Pressurized air supplied at the discharge of gas turbine compressors is ducted to the pressure vessel of pressurized, fluidized-bed, combustor-steam generator modules. The air is introduced in parallel to the beds, entering through distribution grids beneath each bed. Steam generation tubes are buried within the beds and are also arranged as membrane tube walls enclosing the four sides. Crushed coal (1/4 inch x 0) is pneumatically fed at locations just above the air inlet grids at the bottom of each bed. Dolomite is similarly fed to the individual beds. The coal is burned at a temperature below the ash fusion point. Sulfur is removed in the fluid beds through reaction of the SO/sub 2/ with CaCO/sub 3/ and O/sub 2/ to form solid CaSO/sub 4/ and CO/sub 2/ gas. The combustion gases leave the beds at a temperature in the range of ...
1980-05-01
Energy Technology Data Exchange (ETDEWEB)
A technique involving shifting of core fuel loadings was investigated as a method for reducing the neutron flux at points of high damage accumulation in the pressure vessel wall of a light water reactor. Calculations were run for six types of commercial generic PWR. Information is provided on the progress being made to develop and apply the Solid State Track Recorder (SSTR) method for in-situ in- and ex-vessel measurements of neutron exposure parameter values, such as fluence (E > 1.0 MeV) and dpa in iron. A new technique of quantitative track counting, the Buffon needle method, is advanced. It is based on random sampling of the SSTR surface. A desensitized etching technique was developed that resulted in an excellent differential energy response for alpha particles in the 3- to 14-MeV energy range. The optical efficiency of Muscovite mica for manual fission track counting is being redetermined to form a data base for comparison with automatic counting systems. ...
1982-10-01
Heat transfer augmentation using a magnetic fluid under the influence of a line dipole
Energy Technology Data Exchange (ETDEWEB)
Ferrofluids have promising potential for heat transfer applications, since advective transport in a ferrofluid can be readily controlled by using an external magnetic field. However, unlike conventional free or forced convection, ferrohydrodynamic convection is not yet well characterized. A full understanding of the relationship between an imposed magnetic field, the resulting ferrofluid flow, and the temperature distribution is a prerequisite for the proper design and implementation of applications involving thermomagnetic convection. The literature variously assumes constant magnetic fields, does not completely represent the variation in the imposed field, or its descriptions are inaccurate, since the fields do not comply with the Maxwell's equations of electromagnetism. We address this by simulating two-dimensional forced convection heat transfer in a channel with a ferrofluid that is under the influence of a two-dimensional magnetic field created by a ...
2004-04-01
Heat transfer augmentation using a magnetic fluid under the influence of a line dipole
International Nuclear Information System (INIS)
Ferrofluids have promising potential for heat transfer applications, since advective transport in a ferrofluid can be readily controlled by using an external magnetic field. However, unlike conventional free or forced convection, ferrohydrodynamic convection is not yet well characterized. A full understanding of the relationship between an imposed magnetic field, the resulting ferrofluid flow, and the temperature distribution is a prerequisite for the proper design and implementation of applications involving thermomagnetic convection. The literature variously assumes constant magnetic fields, does not completely represent the variation in the imposed field, or its descriptions are inaccurate, since the fields do not comply with the Maxwell's equations of electromagnetism. We address this by simulating two-dimensional forced convection heat transfer in a channel with a ferrofluid that is under the influence of a two-dimensional magnetic field created by a ...
2004-04-01
SUSTAINABLE H/C SYSTEMS FOR CHICKEN FARMS IN SYRIA
Energy Technology Data Exchange (ETDEWEB)
Space heating/cooling systems account for approximately 30% of the global energy consumption. Such systems contribute to global warming by emitting 0.39.1011 MWh of heat and 2.9.1010 tons of CO{sub 2}. There is a general understanding that the way to reduce global warming is a more efficient use of energy and increased use of renewable energy in all fields of the society. The poultry industry in the Mid East is an important business. There are e.g. 13000 chicken farms in Syria producing 172,000 ton of meat. This industry employs directly almost 150,000 people. The total investment in chicken farming is 130 BSP. Even though, the annual mean temperature in Syria is {approx}15-18 C the winter temperatures are close to freezing for two months. Since the chickens need a temperature of 21-35 C, depending on age, approximately 168.103 tons of coal (1170 GWh) is consumed for heating these plants. The chicken farms have no cooling ...
2008-09-30
Recovery of Water from Boiler Flue Gas
Energy Technology Data Exchange (ETDEWEB)
This project dealt with use of condensing heat exchangers to recover water vapor from flue gas at coal-fired power plants. Pilot-scale heat transfer tests were performed to determine the relationship between flue gas moisture concentration, heat exchanger design and operating conditions, and water vapor condensation rate. The tests also determined the extent to which the condensation processes for water and acid vapors in flue gas can be made to occur separately in different heat transfer sections. The results showed flue gas water vapor condensed in the low temperature region of the heat exchanger system, with water capture efficiencies depending strongly on flue gas moisture content, cooling water inlet temperature, heat exchanger design and flue gas and cooling water flow rates. Sulfuric acid vapor condensed in both the high temperature and low temperature regions of the heat transfer apparatus, ...
2008-09-30
Energy Technology Data Exchange (ETDEWEB)
The temperature strongly influences the development time of insects and the understanding of this aspect for natural enemies is essential for its use as biocontrol agents and for mass rearing purpose. The objective of this work was evaluating the effect of different temperatures on the development time of Orius insidiosus (Say, 1832) as well as its thermal requirements. The trials were conducted in climatic chamber at 16, 19, 22, 25, 28 and 31 {+-} 1 deg C; RH 70 {+-} 10% and photo phase 12h. Eggs of Anagasta kuehniella (Zeller, 1879) were provided as food. The embryonic period was 14.0, 8.9, 6.6, 4.8, 3.9 and 3.3 days at 16, 19, 22, 25, 28 and 31 deg C, respectively. Nymphs of all instars (independent of originated sex) were affected by the temperature on their development time; there was a reduction of this period with the increase of the temperature. Males and females presented a development time ...
2005-10-15
COOLOD, Steady-State Thermal Hydraulics of Research Reactors
International Nuclear Information System (INIS)
1 - Description of program or function: The COOLOD-N2 code provides a capability for the analyses of the steady-state thermal-hydraulics of research reactors. This code is a revised version of the COOLOD-N code, and is applicable not only for research reactors in which plate-type fuel is adopted, but also for research reactors in which rod-type fuel is adopted. In the code, subroutines to calculate temperature distribution in rod-type fuel have been newly added to the COOLOD-N code. The COOLOD-N2 code can calculate fuel temperatures under both forced convection cooling mode and natural convection cooling mode. A 'Heat Transfer package' is used for calculating heat transfer coefficient, DNB heat flux etc. The 'Heat Transfer package' is a subroutine program and is especially developed for research reactors in which plate-type fuel is adopted. In case of rod-type fuel, DNB heat flux is calculated by both the 'Heat Transfer package' and Lund DNB ...
International Nuclear Information System (INIS)
We have fabricated nanometer-spaced electrodes on electron-transparent silicon nitride membranes. A thin Cr/Au layer is evaporated on the backside of the membrane which serves as a gate electrode. Using these devices, we have performed three-terminal electron transport measurements on gold nano-particles at liquid helium temperature. Coulomb Blockade features have been observed and the capacitance to the gate has been extracted. After transport measurements, the Cr/Au back gate is removed and the devices are inspected with a transmission-electron microscope (TEM). TEM inspection reveals the presence of a few nano-particles in the nanogap, which is in agreement with the transport measurements. In addition, the nano-particle size as observed by TEM coincides with the one estimated from the gate capacitance value.
2009-10-14
Superconducting strip detectors as position sensitive particle detectors
Energy Technology Data Exchange (ETDEWEB)
The feasibility of using of current-biased superconducting strips for radiation detection is investigated. Narrow Ta strips are exposed to 5.5 MeV [alpha]-particle radiation and the rise-time of the induced voltage pulses is measured as function of temperature and bias current. The rise-time of the voltage signal strongly depends on the site on the strip which is hit by the [alpha]-particle. In order to determine the spatial resolution of a superconducting strip detector, position-sensitive measurements were performed. The maximum lateral resolution estimated so far is 25[mu]m in a 7[mu]m wide, 340 nm thick and 0.6 mm long Ta-strip. (orig.)
1994-02-01
British Library Electronic Table of Contents (United Kingdom)
In this study, the shear viscosities of wood?plastic composites (WPC)/supercritical CO2 (sc-CO2) solutions at different die temperatures and sc-CO2 contents were measured by a slit die attached on a single-screw extrusion system. A theoretical model based on the Carreau-Yasuda model and Arrhenius equation was then developed to describe the shear-thinning behavior of the WPC/sc-CO2 solution. This model was incorporated into a finite element method software, POLYFLOW, to simulate the pressure and velocity field of WPC/sc-CO2 solution flowing through a foaming die. Based on the simulation results, the pressure drop rate and the location of the supersaturation point were estimated to investigate the cell nucleation. The saturation pressure of sc-CO2 in WPC was determined by a magnetic suspensi...
2011-01-01
Structural and electronic properties of the A-15 compounds Nb_3Rh and Nb_3Ir
International Nuclear Information System (INIS)
The structural and electronic properties of the A-15 compounds Nb_3Rh and Nb_3Ir were studied by means of escalar relativistic full-potential linearized augmented-plane wave (FP-LAPW) calculations with generalized gradient corrections. An investigation of the band structure of the hypothetical Nb_3Nb compound was also performed at the theoretical equilibrium lattice constant to ascertain the contribution of the nontransition elements on the B site in these A_3B-type compounds. Band structures and total densities of states were obtained. A rough estimate of the electron-phonon coupling parameter #lambda# as well as of the electronic specific-heat coefficient #gamma# were obtained for both Nb_3Rh and Nb_3Nb, which confirms that this latter is a low-temperature superconductor with T_c - 10K.
2007-04-30
Strategy for forecasting ice breakup and jamming: Saint John River, New Brunswick
Energy Technology Data Exchange (ETDEWEB)
Development of a strategy for forecasting river ice breakup and jamming on the Saint John River in New Brunswick was described. Methods used to identify ice jam-prone areas by simple temperature-based methods to fairly complex computer models using site specific data, were summarized. Recent technological advances in developing forecasts, including the NWRI probe for remotely measuring ice jam thickness, the RIVJAM model for determining stages upstream of an ice jam, and computational procedures for estimating the thrust exerted by ice jams against bridges, were also reviewed. Criteria and recommendations for river ice breakup and ice jamming for the Saint John River were provided. (Abstract only).
1995-12-31
Safety considerations of active process water system shutdown for TAPP - 3 and 4
International Nuclear Information System (INIS)
Active Process Water (APW) System, provided as unitized closed loop system in Tarapur Atomic Power Project Units-3 and 4, serves to remove heat from various heat exchangers. One of the important loads served by APW system is shutdown cooling heat exchangers and if APW shutdown is taken then reactor cannot be maintained in cold shutdown condition. It is estimated that after 7 days of reactor shutdown, if about 20% of the normal cooling flow to shutdown cooling heat exchangers is provided then along with keeping PHT in cold shutdown state, reactor components, moderator, end shield water, calandria vault water and calandria vault concrete temperature can be maintained within technical specification limits for extended duration. (author)
2005-12-01
Protoneutron star in the relativistic mean-field theory
Energy Technology Data Exchange (ETDEWEB)
In this paper the basic properties of non-rotating and slowly rotating protoneutron stars in the relativistic mean-field approach are discussed. The equation of state is the main input to the structure equations. The TM1 parameter set extended to the finite-temperature case is used to obtain the mass-radius relation for protoneutron stars. The occurrence of unstable branches in the mass-radius relation are presented. This allows for the existence of distinctively different evolution tracks for protoneutron stars. The low-density protoneutron star configurations are estimated. The stable configurations obtained for fixed lepton number Y{sub L}=0.4 are compared with those obtained for fixed proton fraction Y{sub P}=0.1776. (author)
2001-09-01
Modeling and control of a novel heat exchange reactor, the Open Plate Reactor
British Library Electronic Table of Contents (United Kingdom)
A new chemical reactor, the Open Plate Reactor, is being developed by Alfa Laval AB. It combines good mixing with high heat transfer capacity into one operation. With the new concept, highly exothermic reactions can be produced using more concentrated reactants. A nonlinear model of the reactor is derived and a control system is developed. For temperature control a cooling system is designed and experimentally verified, which uses a mid-ranging control structure to increase the operating range of the hydraulic equipment. A Model Predictive Controller is proposed to maximize the conversion under hard input and state constraints. An extended Kalman filter is designed to estimate unmeasured concentrations and parameters. Simulations show that the designed control system gives high conversion ...
2007-01-01
Magnetic properties of ErPd_2Si_2 from magnetization Moessbauer and neutron diffraction measurements
International Nuclear Information System (INIS)
Magnetization, neutron diffraction and "1"6"6Er Moessbauer measurements on ErPd_2Si_2 are reported. Below 4.8 K ErPd_2Si_2 orders AF with complex modulated magnetic structures, where the Er moments are aligned along the c-axis. At 1.5 K a squared structure with #mu#_E_r #approx# 7.8(1)#mu#_B is found while a saturation Er moment of 8.2(2)#mu#_B is inferred from the hyperfine field data. The temperature dependence of the Moessbauer spectra in the paramagnetic region is explained in the framework of a relaxation model implying excited crystal field levels. Its analysis is used to estimate the B"m_n CEF parameters. (orig.).
Laser-Cooling of Liquid Water by the Ar-Xe Laser Radiation
An effect of laser-cooling of water was observed for the first time with a temperature decrease dT = -2.2 K after irradiation of liquid water surface by a powerful Ar-Xe pulse laser with a pulse energy of about 1 J and wavelength L = 1.73, 2.63 and 2.65 um. The discovered effect can apparently be ascribed to the optical excitation of vibrational states of H2O molecules followed by an endothermic consolidation of chemically active excited molecules into a quasi-stable cluster-like structure. The measured time dependences of the cooling effect show that a typical life time of the new state of water amounts to hours. It has also been shown that the life time of the excited vibrational molecular states due to a radiation trapping effect can be estimated to at least hundreds of seconds.
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
Visits were made to selected manufacturing units with 25 or more employees. Information was gathered on energy consumption and advice was given on the opportunities available for improving the efficiency of energy use. Potential energy savings are estimated and recommendations are made on the action that should be taken to improve the efficiency of energy use. In the footwear industry space heating controls, improvements in boiler plant and steam services along with building insulation provide most of the savings potential. In the leather industries major energy saving opportunities can be found in low-temperature drying, and heat recovery, where the use of heat pumps could contribute substantial savings in drying and process water heating. Boiler controls and good housekeeping are areas where firms can make worthwhile savings at very little capital cost. (MCW)
1980-11-01
Hydrotalcites with different Al/Al+Mg ratios, and prepared at different pH and different aging temperatures of the gel were used as precursors of Mg-Al mixed oxides, and their textural and physicochemical properties were determined. A complete reaction network for the isopropanol decomposition on these catalysts has been established, and it is shown that the concentration of acetone in the products cannot always be used for a direct estimation of the rate of dehydrogenation. The Al/Al+Mg ratio for which the maximum in activity is obtained depends on the base strength needed for each particular reaction. For dehydrogenation of isopropanol, this is found at Al/Al+Mg [approx] 0.25. 36 refs., 10 figs., 2 tabs.
1994-07-01
Heat capacity and magnetic ordering of two cerium sulfides, CeS/sub 1. 393/ and CeS/sub 1. 457/
Energy Technology Data Exchange (ETDEWEB)
Heat-capacity (0.5--20 K) and magnetic-susceptibility (4--300 K) measurements have been made on two cerium sulfide samples having compositions as CeS/sub 1.393/ and CeS/sub 1.457/. These materials follow the Curie-Weiss law above 100 K, and become ferromagnetically ordered near 6 and 3 K, respectively. Shift of the ordering to higher temperatures under applied magnetic fields is also observed in CeS/sub 1.457/. The estimated effective magnetic moment and entropy associated with the ordering are consistent with the paramagnetic nature of Ce/sup 3 +/ (4f/sup 1/) in a crystalline environment.
1982-08-01
International Nuclear Information System (INIS)
This paper describes the heat transfer augmentation and the flow situation around a single spacer (a cylindrical rod) on the heated surface of a parallel plate duct in order to examine basically the effects of the spacer in the fuel elements of a high temperature gas-cooled reactor. The ends of the cylindrical rod contact the upper and lower planes. A thermosensitive liquid crystal film is used to indicate the effective area for the heat transfer. The mean Nusselt number, which is estimated within the optional distance from the spacer to the downstream direction, peaks at a dimensionless distance of X/D = 1-3, and after that decreases gradually with the flow direction. The manner in which heat transfer corresponds to the flow situation is also examined. The horseshoe vortex, produced around the spacer, affects the wake and contributes to the increase of the local heat transfer. (author).
1988-01-01
International Nuclear Information System (INIS)
From the first principles total energy calculations based on full-potential linear augmented plane wave method (FPLAPW), the elastic properties of XPt_3 (X=V, Cr, Mn, Fe, Co, Ni) are reported here. Theoretical values of Young's modulus, shear modulus, Poisson's ratio and Debye temperature are estimated from the computed elastic constants. From the analysis of the ratio of shear to bulk modulus, it is found that these intermetallic compounds are ductile in nature except CrPt_3, which is brittle. The calculated results are compared with other reported values.
2010-06-01
Formation evaluation in liquid-dominated geothermal reservoirs
Studies relative to some formation evaluation aspects of geothermal reservoirs are reported. The particular reservoirs considered were the liquid dominated type with a lithology of the sedimentary nature. Specific problems of interest included the resistivity behavior of brines and rocks at elevated temperatures and studies on the feasibility of using the well log resistivity data to obtain estimates of reservoir permeability. Several papers summarizing the results of these studies were presented at various technical meetings for rapid dissemination of the results to potential users. These papers together with a summary of data most recently generated are included. A brief review of the research findings precedes the technical papers. Separate abstracts were prepared for four papers. Five papers were abstracted previously for EDB.
1981-04-01
Fission neutron damage rates and efficiencies in several metals
International Nuclear Information System (INIS)
Initial rates of resistivity-measured low-temperature damage production by fission-spectrum fast neutrons have been determined for 14 metals in the same very well characterized irradiation facility. Six of these metals were fcc, 5 bcc, and 3 hcp. Most were of quite high purity. Observed damage rates, after correction for all known extraneous resistivity-producing effects, were compared with rates predicted by the damage calculation code RECOIL, using parameters chosen from the literature. These parameters, effective displacement threshold energy, E/sub d/, and Frenkel-pair resistivity, rho/sub F/, were in many cases only best estimates, the further refinement of which may be aided by the present results. Damage efficiencies (measured/predicted rates) follow the same trends by crystal classes as seen in other fast-neutron studies.
2003-04-01
International Nuclear Information System (INIS)
The biota of the Mississippi River in an ecological recovery zone near Red Wing, MN was studied before and after start-up of a nuclear plant to acquire baseline data and to estimate changes due to thermal addition. Thermal addition produced significant decreases in primary production in a plant region during summer month periods when water temperatures were near 36C. Extensive fisheries studies and sonar tagging/tracking of S. vitreum were performed. Comparison of fisheries results with other riverine, lake, and pond studies indicated a favorable environment for the success of the fish species studied. Qualitative macroinvertebrate surveys were conducted.
International Nuclear Information System (INIS)
The absorption and magnetic circular dichroism spectra of [N(n-Bu)_4]"+[(MeCp)_3PrCl]"- dissolved in 2-MeTHF were measured at room and at low temperatures. On the basis of these spectra the crystal field splitting pattern could be derived. The parameters of an empirical Hamiltonian were fitted to the energies of 42 levels to give an r.m.s. deviation of 23 cm"-"1. From the crystal field parameters obtained the crystal field strength of the ligand collective was estimated. Compared with neutral Cp_3Pr circle B complexes the crystal field strength of the anionic [(MeCp)_3PrCl]"- moiety is unusually low. (orig.)
1998-07-24
Elastic properties, hardness and indentation fracture toughness of #beta#-sialons
International Nuclear Information System (INIS)
Dense samples of #beta#-sialons (with z from 1 to 4) were pressuressly sintered for different time (15-240 minutes) and at relatively low temperature of 1600 C using single-phase #beta#-sialon powders synthesized by combustion nitridation. The samples were characterized using ultrasonic method for determination of elastic properties (E,G,#mu#). Also, hardness by Knoop and fracture toughness by Vickers indentation microfracture method was estimated. With increasing z number Young's modulus decreases from 293 to 179 GPa. Simultaneously Poisson ratio increases by about 30%. The highest values of hardness and fracture toughness were obtained for sialon with z equal to 1. (orig.).
1993-10-04
Development of L-band pillbox RF window
Energy Technology Data Exchange (ETDEWEB)
A pillbox RF output window was developed for the L-band pulsed klystron for the Japanese Hadron Project (JHP) 1-GeV proton linac. The window was designed to withstand a peak RF power of 6 MW, where the pulse width is 600 {mu}sec and the repetition rate is 50 Hz. A high power model was fabricated using an alumina ceramic which has a low loss tangent of 2.5x10{sup -5}. A high power test was successfully performed up to a 113 kW RF average power with a 4 MW peak power, a 565 {mu}sec pulse width and a 50 Hz repetition rate. By extrapolating the data of this high power test, the temperature rise of the ceramic is estimated low enough at the full RF power of 6 MW. Thus this RF window is expected to satisfy the specifications of the L-band Klystron. (author).
1994-12-31
Defect creation by electronic processes in MgO bombarded with GeV heavy ions
Energy Technology Data Exchange (ETDEWEB)
To study the defect creation induced by electronic processes in refractory oxides, MgO single crystals were irradiated with high energy tin, uranium and lead ions. Optical absorption measurements showed that F-type centers (oxygen vacancies with trapped electrons) were created during irradiation. The total number of centers per unit area of bombarded sample increases linearly with irradiating fluence. The main part of the point defects was found to arise from electronic processes. The concentration of F-type centers induced by ionization increases with the electronic energy losses. Assuming a saturation of point defect concentration at high fluences, F-type center creation cross sections could be estimated. The influence of irradiation temperature and of the velocity of the bombarding ions are discussed.
1996-12-31
British Library Electronic Table of Contents (United Kingdom)
Cyclization of deproteinized natural rubber (DPNR) or purified natural rubber latex was effectively performed in latex phase by using trimethylsilyl-trifluoromethane sulfonate or trimethylsilyl triflate (TMSOTF) as a novel catalyst, which is still not reported in the case of natural rubber latex. Various cyclization conditions affecting the degree of cyclization were studied, such as dry rubber contents, temperature, TMSOTF concentrations, and time. The cyclized products were characterized by FTIR, Raman, 1H-, and 13C-NMR spectroscopies, as well as DSC and TGA. The degree of cyclization was estimated by 1H-NMR spectrum. It was found that the degree of cyclization in NR was a function of cyclization conditions. The thermal stability of cyclized DPNR increased with the degree of cyclization....
2007-01-01
A radiation hardening model of 9%Cr-martensitic steels including dpa and helium
British Library Electronic Table of Contents (United Kingdom)
This paper provides a physically-based engineering model to estimate radiation hardening of 9%Cr-steels under both displacement damage (dpa) and helium. The model is essentially based on the dispersed barrier hardening theory and the dynamic re-solution of helium under displacement cascades but incorporating a number of assumptions and simplifications [Trinkaus, J. Nucl. Mater. 318 (2003) 234-340]. As a result, the kinetics of the damage accumulation kept fixed, its amplitude is fitted on one experimental condition. The model was rationalized on an experimental database that mainly consists of 9%Cr-steels irradiated in the range of 50-600degreeC up to 50dpa and with a He-content up to 5000appm. The test temperature effect is taken into account through a normalization procedure based on the...
2009-01-01
A fundamental study of the heat transfer and flow situation around a spacer
International Nuclear Information System (INIS)
This paper describes the heat transfer augmentation and flow situation around a single spacer (a circular cylinder) on a heated surface in a parallel plate duct in order to examine basically the effects of the spacer in the fuel elements of a High Temperature Gas-cooled Reactor. A thermosensitive liquid crystal film was used to clarify the effective region of the heat transfer. The mean Nusselt number, which was estimated within arbitrary distance from the spacer to the downstream direction, took a peak at the dimensionless distance X/D = 1 #approx# 3, and after that decreased gradually with flow direction. How heat transfer corresponds to the flow situation is also examined. The horseshoe vortex, produced around the spacer, affects the wake and contributes to the increase of the local heat transfer. (author).
1986-01-01
A He-gas Cooled, Stationary Granular Target
In the CERN approach to the design of a neutrino factory, the repetition frequency of the proton beam is high enough to consider stationary solid targets as a viable solution for multi-MW beams. The target consists of high density tantalum spheres of 2 mm diameter which can efficiently be cooled by passing a high mass flow He-gas stream through the voids between the Ta-granules. Very small thermal shocks and stresses will arise in this fine grained structure due to the relatively long burst of 3.3 ms from the SPL-proton linac. In a quadruple target system where each target receives only one quarter of the total beam power of 4 MW, conservative temperature levels and adequate lifetimes of the target are estimated in its very high radiation environment. A conceptual design of the integration of the target into the magnetic horn-pion-collector is presented.
2003-01-01
48 CFR 252.215-7002 - Cost estimating system requirements.
... 2010-10-01 false Cost estimating system requirements. 252...Clauses 252.215-7002 Cost estimating system requirements. As...use the following clause: Cost Estimating System Requirements (DEC...
2010-10-01
Los Alamos PC estimating system
Energy Technology Data Exchange (ETDEWEB)
The Los Alamos Cost Estimating System (QUEST) is being converted to run on IBM personal computers. This very extensive estimating system is capable of supporting cost estimators from many different and varied fields. QUEST does not dictate any fixed method for estimating. QUEST supports many styles and levels of detail estimating. QUEST can be used with or without data bases. This system allows the estimator to provide reports based on levels of detail defined by combining work breakdown structures. QUEST provides a set of tools for doing any type of estimate without forcing the estimator to use any given method. The level of detail in the estimate can be mixed based on the amount of information known about different parts of the project. The system can support many different data bases ...
1987-01-01
Virtualness of the Cost Estimating Community
... Accession Number : ADA540017. Title : Virtualness of the Cost Estimating Community. Descriptive Note : Master's thesis. ...
2011-03-01
Pros, Cons, and Alternatives to Weight Based Cost Estimating
Many cost estimating tools use weight as a major parameter in projecting the cost. This is often
2011-01-01
Estimating Aircraft Airframe Tooling Cost: An Alternative to ...
... Abstract : The purpose of this study was to evaluate the tooling cost estimating equation of the DAPCA III model and determine if more accurate ...
1988-09-01
COST EVALUATION AND COST ESTIMATING FOR ...
... Accession Number : AD0833945. Title : COST EVALUATION AND COST ESTIMATING FOR SHIPBOARD ELECTRONIC EQUIPMENT. VOLUME II. ...
1967-04-01
International Nuclear Information System (INIS)
In this letter a method to estimate the visco-elastic response of monolithic ceramics to cyclic loading conditions at high temperatures is proposed. A relation is observed between the visco-elastic energy dissipation measured for two silicon nitride materials, and the structural characteristics of their respective intergranular phases. Some consequences for the fatigue resistance of the tested materials, and of non-transforming monolithic ceramics in general, are discussed. Two batches (G for glassy and C for crystalline) of SiAlON have been studied. The G-batch is obtained by pressureless sintering of silicon nitride powder with Y_2O_3 (6 wt%) and 6AlN-SiO_2 (5 wt%) as sintering additives. The main phase after sintering is #beta#-sialon. Upon cooling from the sintering temperature the amorphous intergranular residues of the sintering additives and of SiO_2, which is unavoidably present as a thin layer on the silicon ...
Tokamak and laboratory modeling of hydrocarbon film deposition on metallic mirrors
International Nuclear Information System (INIS)
In this work, amorphous hydrocarbon (a-C:H) film deposition on metallic mirrors was studied during working shots in tokamak T-10 and at exposure in Ar/CHD3/D2 dc magnetron discharge in a special laboratory high vacuum setup. Analysis of film composition (including hydrogen content) was carried out using nuclear physical methods. Thickness and optical parameters (refractive and extinction coefficients) of the films were estimated by ellipsometry. Laboratory films can be characterized as soft a-C:H films in comparison with hard tokamak films (? = 1.2 and 1.8 g/cm3, respectively). For the first one, a linear dependence of deposition rate on mirror temperature was observed in a wide temperature range. The addition of methane into initial Ar/D2 magnetron gas mixture leads to an increase of deposition rate. The data obtained should be taken into account to prevent hydrocarbon film formation on the surface of first mirrors in ...
2009-06-15
Energy Technology Data Exchange (ETDEWEB)
In the present work temperature dependences of heat capacity of carbosilane dendrimers with butyl terminal groups of the third and the fourth generations as well as of the fifth and the sixth generations have been determined first in the range from 6 to 340K and between 6 and 600K, respectively, by precision adiabatic vacuum and dynamic calorimetry. In the above temperature ranges the physical transformations have been detected and their thermodynamic characteristics have been estimated and analyzed. The experimental data were used to calculate standard thermodynamic functions, namely the heat capacity C{sub p}{sup o}(T), enthalpy H{sup o}(T)-H{sup o}(0), entropy S{sup o}(T)-S{sup o}(0) and Gibbs function G{sup o}(T)-H{sup o}(T), for the range from T->0 to (340-600)K. Linear dependences of changing the corresponding thermodynamic functions of the dendrimers on their molecular weight and the number of butyl groups on ...
2006-01-15
International Nuclear Information System (INIS)
A pair of bundles is placed in a shuttle tube, which is enclosed by a carriage tube kept inside the Shuttle Transfer Station (STS). It takes about 90 minutes for the spent fuel bundles to travel from the reactor channel to Transfer Magazine (TM). Subsequently, the dry transfer operation takes about 4 minutes. An emergency air cooling flow rate of 600 m3/hr is supplied to cool the spent fuel bundles after they reach the STS, following lapse of 4 minutes of spent fuel dry transfer, in case the bundles are not submerged in the light water in STS. A thermal and hydraulic safety analysis has been done to estimate the maximum sheath temperature, if the spent fuel bundles are stuck at a location of 30 mm below the normal location aligned to the TM port. This position of the spent fuel will have least cooling from the emergency cooling airflow. At the same time, the shuttle tube carrying the spent fuel bundle is just above the water. From the analysis ...
2006-11-13
Energy Technology Data Exchange (ETDEWEB)
This paper deals with the externally coal-fired combined cycle (EFCC). A process simulation for different configurations of the EFCC-process is carried out as well as an investigation of the effect of the key parameters such as the gas turbine inlet temperature and the compressor intake airflow. The results show a promising potential of the efficiency. One component of this combined gas and steam turbine cycle is a high temperature heat exchanger that has to withstand the extrem chemical and thermal operating conditions. Fibre reinforced ceramics and combinations of them with monolithic ceramics seem to be the most promising materials for this application. A cost estimating of the EFCC-process shows that a competitive operation should be possible. (orig.) [Deutsch] Die Ergebnisse der Prozesssimulationen weisen ein vielversprechendes Wirkungsgradpotential des extern kohlebefeuerten Gasturbinenprozesses auf. Der fuer dieses ...
1996-12-31
The use of calcium silicate bricks for retrospective dosimetry
International Nuclear Information System (INIS)
The suitability of calcium silicate bricks (CSBs) for the retrospective measurement of gamma dose using luminescence techniques has been investigated. Bricks of this type are distinguished from fired clay bricks by containing negligible clay and requiring comparatively low temperature treatment during manufacture. They have been used widely in the construction f buildings in the Former Soviet Union since the 1970s but hitherto have not been used for retrospective dosimetry measurements. A procedure based on the se of the 210 deg. C thermoluminescence (TL) peak of quartz was tested with granular quartz extracted from three types of CSB, one of which had been taken from a settlement downwind of Chernobyl. The degree to which the residual geological TL signal within the temperature range of the 210 deg. C L peak had been reduced during manufacture varied with brick type; the levels of residual TL corresponded, in the samples tested, to absorbed ...
2004-02-01
Energy Technology Data Exchange (ETDEWEB)
The partial pressures of the components (ThCl/sub 4/, MCl and MThCl/sub 5/) in the saturated vapours of ThCl/sub 4/ solutions in molten LiCl, NaCl, KCl, RbCl and CsCl are determined as a function of temperature (900 to 1200 K) and ThCl/sub 4/ concentration (2 to 50 mol% ThCl/sub 4/) by dynamic method. Thorium tetrachloride volatility is shown to exceed that of alkali chloride from the melts containing less than 98 LiCl or NaCl, 83 KCl, 67 RbCl and 48 mol% CsCl. From experimental observations the decomposition potential of the electrolytes under investigation was estimated in temperature and concentration ranges of our measurements. Under otherwise equal conditions, it increases in the series of alkali chlorides from LiCl to CsCl.
1984-01-01
Zinc molybdate (ZnMoO4) single crystals were grown for the first time by the Czochralski method and their luminescence was measured under X ray excitation in the temperature range 85-400 K. Properties of ZnMoO4 crystal as cryogenic low temperature scintillator were checked for the first time. Radioactive contamination of the ZnMoO4 crystal was estimated as <0.3 mBq/kg (228-Th) and 8 mBq/kg (226-Ra). Thanks to the simultaneous measurement of the scintillation light and the phonon signal, the alpha particles can be discriminated from the gamma/beta interactions, making this compound extremely promising for the search of neutrinoless Double Beta Decay of 100-Mo. We also report on the ability to discriminate the alpha-induced background without the light measurement, thanks to a different shape of the thermal signal that characterizes gamma/beta and alpha particle interactions.
2010-01-01
Kondo effect and impurity-impurity interaction in (La, Ce)B_6 alloys
International Nuclear Information System (INIS)
Measurements of the magnetic susceptibility betweeen 0.03 and 300 K and of the magnetization between 0.05 and 10 K for magnetic fields up to 60kOe have been used to investigate effects from the interaction between the conduction electrons and local magnetic moments in (Lasub(1-x)Cesub(x))B_6 alloys (0.0007<=x<=0.10). For Ce concentrations x<0.006 the data show Kondo-type single impurity behaviour at low temperatures with a transition from a magnetic to a non-magnetic regime of the Ce ions. In the magnetic regime the impurity susceptibility follows a Curie-Weiss law, and in the non-magnetic regime it varies with T"2. An external magnetic field gradually restores the free-ion behaviour of the Ce impurities. For more concentrated alloys interactions between the impurities are observed. The RKKY interaction strength derived is more than two orders of magnitude smaller than in the Kondo system CuFe. Values of the s-f exchange integral, J, ...
1978-01-01
Full autonomous monitoring tools inside nuclear reactor building
Energy Technology Data Exchange (ETDEWEB)
In this paper, we define, design and test a radiation tolerant autonomous monitoring tool for nuclear embedded applications. The goal of the instrumentation system was to record the values of some parameters such as dose, temperature or vibrations appearing inside the containment building of nuclear power plants. The knowledge of these parameters will be a good help for predictive maintenance of the power plant components. For the design of the monitoring tool, we rely on commercial-off-the-shelf (COTS) low power electronic components to use battery-supplied power. A large amount of components starting from discrete transistors or logic units to memories and micro-controllers was associated to define and design a prototype. We then confirm the environment conditions tolerance estimated to up to 2 kGy of total dose and 80 C for temperature by on-line irradiation experiments for individual components and functions and ...
2009-07-01
Energy Technology Data Exchange (ETDEWEB)
The thermal contact resistance between balls and inner and outer rings of thermally steady space-use deep groove ball bearings was studied experimentally to verify the validity of the previously proposed calculation method for the resistance. The 440C stainless steel single row bearing was used for measuring its steady state temperature distributions in a vacuum environment under axial, radial and combined load conditions. As a result, the experimental results of the resistance well agreed with calculated ones under each load condition resulting in the sufficient validity at nearly the same surface roughness. It was necessary to apply a static equivalent radial load to calculation under the combined load that a contact angle is larger than the angle of resultant force dependent on both load components. In experiments under only radial load, measurement of outer ring temperatures was necessary at some points with no contact with balls to avoid ...
1992-12-05
Constant-pressure charging of a liquid-dominated geothermal reservoir
Energy Technology Data Exchange (ETDEWEB)
A two-dimensional mathematical model of a fault controlled geothermal reservoir has been developed. Heated water rising in a fault is assumed to charge a reservoir which is overlain by a thin impermeable, thermally conducting cap rock. The mass flow rate or the pressure associated with the charging process at the fault inlet is unknown and can only be estimated. Thus, the pressure in the fault at the bottom of the reservoir is assumed to be prescribed. Quasi-analytic solutions for the distributions of velocity, pressure, and temperature are obtained in the fault-reservoir system for high Rayleigh number flow. In this approximation, the upwelling fluid does not cool off appreciably until it reaches the cold upper boundary of the reservoir and encounters conductive heat loss. The thermal boundary layer, which is thin at the top of the fault, grows outward laterally and occupies the full thickness of the aquifer in the far-field. This study shows ...
1982-03-01
Application of the CFAST zone model to the Fire PSA
Energy Technology Data Exchange (ETDEWEB)
The integrity of the cables located in the target room is very important in the Fire PSA, because the CDF and CCDP are changed according to the results of a cable integrity that depends on the surrounding gas temperature. The conservative assumptions used in the Fire PSA typically specify that all of the equipment and cables of a room would fail when a fire happens in the room. But the realistic assessment of a fire risk by using a fire simulation tool has become necessary in the Fire PSA as described in the ANS Fire PRA Standard. This paper evaluates the cable integrity of eight pump rooms in the nuclear power plant by using the CFAST zone fire model. The upper layer gas temperature of each room is estimated, and an analysis based on the results of model simulations is used to judge the cable integrity. According to the analysis results, the integrity of the cable located in the upper layer in the pump rooms is maintained ...
2010-10-15
A radiation hardening model of 9%Cr-martensitic steels including dpa and helium
International Nuclear Information System (INIS)
This paper provides a physically-based engineering model to estimate radiation hardening of 9%Cr-steels under both displacement damage (dpa) and helium. The model is essentially based on the dispersed barrier hardening theory and the dynamic re-solution of helium under displacement cascades but incorporating a number of assumptions and simplifications [Trinkaus, J. Nucl. Mater. 318 (2003) 234-340]. As a result, the kinetics of the damage accumulation kept fixed, its amplitude is fitted on one experimental condition. The model was rationalized on an experimental database that mainly consists of ?9%Cr-steels irradiated in the range of 50-600 deg. C up to 50 dpa and with a He-content up to 5000 appm. The test temperature effect is taken into account through a normalization procedure based on the change of the Young's modulus and the anelastic deformation that occurs at high temperature. Despite the large experimental scatter, ...
2009-04-30
A proposed scheme for coal fired combined cycle and its concise performance
Energy Technology Data Exchange (ETDEWEB)
For IGCC, the primary investment is too high due to the demand of high gasification efficiency. For PFBCC, the thermal efficiency is too low due to the relatively low turbine inlet temperature and the hot working medium of the gas turbine is not easy to clean. A new scheme is proposed for coal fired combined cycle to overcome the main drawbacks of IGCC and PFBCC. The research targets are developing a new cycle construction of coal fired combined cycle to raise the efficiency and reduce the primary investment. Actually, the new scheme is a synthesis of some existing proposals. It adopts partial gasification to reduce the primary investment of the gasification equipment. The un-gasified surplus solid is then fed to a pressurized fluidized bed boiler, but adopting Curtiss Wright type external combustion to lower the ash content in the working medium. The gas fuel from the partial gasifier is combusted in a top combustor to further increase the working medium ...
2007-06-15
Energy Technology Data Exchange (ETDEWEB)
A first, partial, assessment is included of the low- to medium-temperature geothermal reserves in 20 Mexican States and their aggregate value. The assessment covers about 29.16% of the identified geothermal-surface manifestations in the public database. For reserve assessments, we use the volumetric method, supplemented with Montecarlo simulations and statistics, to quantify inherent uncertainties. Our estimations are presented on a state-by-state basis. We estimate the aggregated reserves of the 20 states as between 7.7 x 1016 and 8.6 x 1016 kJ, with 90% confidence. The most likely reservoir temperatures range between 60-180 degrees Celsius, with a mean of 111 degrees Celsius. Such massive amounts of recoverable energy-and the associated temperatures-are potentially important for the economic development of nearby localities and the nation. [Spanish] En este trabajo se hace una ...
2009-07-15
Patterns of lineage diversification in the genus Naso (Acanthuridae).
The evolutionary history of the reef fish genus Naso (F. Acanthuridae) was examined using a complete species-level molecular phylogeny of all recognized (19) species based on three loci (one nuclear ETS2 and two mitochondrial 16S, cyt b). This study demonstrates that distinct foraging modes and specialized body shapes arose independently at different times in the evolutionary history of the genus. Members of the subgenus Axinurus, characterized by a scombriform morphology, caudal fin structure and pelagic foraging mode, were consistently placed basal to the remaining Naso species, suggesting that pelagic foraging is plesiomorphic and benthic foraging derived in this genus. We used a genus-level phylogeny (nuclear marker, ETS2), which included several taxa from all other acanthurid genera, to obtain a range of age estimates for the most recent common ancestor of the genus Naso. These age estimates (range of 52-43.3 MY) were then used to ...
2004-07-01
Passive, integrated measurement of radon using 5A synthetic zeolite and blue silica gel
Energy Technology Data Exchange (ETDEWEB)
Synthetic zeolite of 0.5 nm pore size (5A) and blue silica gel were tested to determine their capability to be used as radon collectors. Tests conducted in a radon chamber under controlled conditions of temperature and relative humidity indicate that simple, inexpensive and maintenance-free passive devices containing about 250 g of synthetic zeolite or about 270 g of blue silica gel in open face metal canisters that can measure radon conveniently and adequately, the latter though being suitable only for dry-medium dry atmosphere with quite high radon concentrations. Both materials can be recycled for reuse, in a way similar to the recycle and reuse of active carbon. The amount of radon adsorbed in such collectors is determined by counting the gamma rays from the radon decay products. The lower limit of detection (LLD) is estimated to {approx}45 Bqm{sup -3} for the synthetic zeolite and to {approx}350 Bqm{sup -3} for the blue silica gel, for an ...
2010-01-15
Accident analysis in research reactors
International Nuclear Information System (INIS)
Full text: Full text: The incomplete understanding of the complex mechanisms connected with the interaction between thermal-hydraulic and neutron kinetics still challenges the design and the operation of nuclear reactors and imposes the adoption of conservatism in the evaluation of safety limits. The recent availability of powerful computer and computational techniques together with the continuing increase in operational experience suggests the revisiting of those areas and the identification of design/operation requirements that can be relaxed. So far, almost all of the safety analyses of research reactors have been performed using conservative computational tools such as channel codes but, nowadays, the application of Best-Estimate (BE) methods constitutes a real necessity. The global aim of the current work is an attempt to apply the best-estimate system thermal-hydraulic code Relap5. For this purpose, the generic IAEA research reactor ...
2006-10-15
Turbulent heat transfer augmentation using microscale disturbances inside the viscous sublayer
Energy Technology Data Exchange (ETDEWEB)
The authors report here on an experimental study of heat transfer augmentation in turbulent flow. Enhancement strategies employed in this investigation are based on the near-wall mixing processes induced in the sublayer through appropriate wall and near-wall streamwise-periodic disturbances. Experiments are performed in a low-turbulence wind-tunnel with a high-aspect-ratio rectangular channel having either (a) two-dimensional periodic microgrooves on the wall, or (b) two-dimensional microcylinders placed in the immediate vicinity of the wall. It is found that microdisturbances placed inside the sublayer induce favorable heat-transport augmentation with respect to the smooth-wall case, in the near-analogous momentum and heat transfer behavior are preserved; a roughly commensurate increase in heat and momentum transport is termed favorable in that it leads to a ...
1992-05-01
International Nuclear Information System (INIS)
Quantitative gated SPECT (QGS) was evaluated in 7 normal volunteers and 31 patients with cardiac diseases. Adequate cut off value of a prefilter was 0.45. In phantom, the left ventricular volume value was 93.9% of determined value by 180-degree projection in L type and 98.8% by 360-degree projection in opposed type. In normal volunteers, LVEF measured by QGS program related to value by first pass method. As for functional map, regional EF and wall motion decreased at the septum side, and wall thickening at base side of heart. Good correlation was recognized (p<0.0001) between blood flow image and functional map (regional EF and wall thickening). In 20 cases of acute myocardial infarction, lesion was detected conspicuously in regional EF and wall motion. The accuracy of coronary arterial stenosis improved in functional map (regional EF 92%, wall motion 92% and ...
1998-08-01
Review of JT-60U experimental results from February to October, 1999
International Nuclear Information System (INIS)
In 1999, the plasma parameters of reversed shear (RS) plasmas had been extended in 1) DT-equivalent fusion power gain Q_D_T"e"q - 0.5 (n_D(0)#tau#_ET_i(0) - 4x10"2"0 m"-"3#centre dot#keV#centre dot#s) for 0.8 s and 2) full non-inductive current drive with 80% of the bootstrap current fraction. Physics of the internal transport barriers (ITBs) in RS plasmas, including the energy transport and the formation of ITB, were extensively studied. A nearly full current drive (92% non-inductively) was obtained with negative ion based neutral beam (NNB) injection (360 keV, 3.4 MW) in a high #beta#_p H-mode plasma (I_p=1.5 MA, B_T=3.7 T, q_9_5=4.2) with high plasma performance (#beta#_N=2.4 and H_8_9=2.56). Rise in the central electron temperature (T_e - 9 keV) resulted in the current drive efficiency #eta#_C_D of NNB reached 1.3x10"1"9 A/W/m"2, the highest for the neutral beam current drive. As for the H-mode plasmas, decrease in the pedestal ion ...
1994-06-01
The EU HT test programme of ITER primary wall small scale mock ups
International Nuclear Information System (INIS)
This paper summarises the main results obtained so far in the frame of the EU Home Team test programme of ITER primary wall small scale mock ups. It describes briefly the fabrication method of the mock ups, the test conditions and the main results obtained with high heat flux and thermal fatigue tests of Cu alloy/stainless steel and beryllium/Cu alloy/stainless steel mock ups. The results obtained so far show good thermal fatigue performance and operation margin of the ITER primary first wall concept. (author)
1998-09-07
Energy Technology Data Exchange (ETDEWEB)
It is postulated that a break of a thin-walled pipe does not cause a subsequent break in the pipe in the vicinity of a plastic hinge even when the wall is weakened by a 60 circumferential crack of a depth of 30% of the wall thickness on the tension side. This pipe behavior is the result of plastic buckling in the compression side and applies to pipes of diameter-to-thickness ratio larger than 20. For this type of pipe, the axial strains decrease with increasing diameter-to-thickness ratio in the tension side. As the pipe is only loaded in one direction, there is no cyclic behavior that can trigger a subsequent break. (orig.)
1993-10-01
Main achievements of the EU HT test programme of ITER primary wall small scale mock ups
International Nuclear Information System (INIS)
This paper presents the main achievements of the European Home Team (EU HT) test programme of ITER primary wall small scale mock ups. It describes briefly the fabrication method of the mock ups, the test conditions and the main results obtained with high heat flux and thermal fatigue tests of Cu alloy/stainless steel and beryllium/Cu alloy/stainless steel mock ups. The results obtained so far show very good thermal fatigue performance and operation margin of the ITER primary first wall concept.
2000-11-01
Magnetization reversal phenomena and domain wall behaviours in nanostructured magnetic systems
International Nuclear Information System (INIS)
Several recent experiments on micro- (or nano-) structured samples of ferromagnetic materials are introduced. Magnetization reversal phenomena are investigated on submicron wire samples of trilayer structure using the giant magnetoresistance effect. Domain wall movements are sensitively monitored by resistivity measurements and the velocity of propagation is determined. The contribution of domain wall to the resistivity is argued from the results on artificially designed samples of a spring-magnet system. In circular dots of permalloy, the existence of vortex magnetization is confirmed and the reversal of the vortex core magnetization is studied from magnetic force microscopy measurements. (author)
2001-09-23
Creation of an antiferromagnetic exchange spring
We present evidence for the creation of an exchange spring in an antiferromagnet due to exchange coupling to a ferromagnet. X-ray magnetic linear dichroism spectroscopy on single crystal Co/NiO(001) shows that a partial domain wall is wound up at the surface of the antiferromagnet when the adjacent ferromagnet is rotated by a magnetic field. We determine the interface exchange stiffness and the antiferromagnetic domain wall energy from the field dependence of the direction of the antiferromagnetic axis, the antiferromagnetic pendant to a ferromagnetic hysteresis loop. The existence of a planar antiferromagnetic domain wall, proven by our measurement, is a key assumption of most exchange bias models.
2004-04-06
Conjugate parallel-flowing free and forced convection boundary layers on vertical wall sides
Energy Technology Data Exchange (ETDEWEB)
The paper describes an analytical study of two parallel-flowing boundary layers of free and forced convection modes on the facing sides of a vertical thin wall. The two layers are analyzed separately within the framework of boundary layer theory, and coupled by the matching conditions at wall. Numerical data are obtained for a wide range of a dimensionless conjugation parameter {zeta} relating the heat transfer effectiveness of two convection modes. Based on these data, an expression for calculating the conjugate mean Nusselt number as a function of {zeta}-parameter is found by means of a curve-fitting method. (orig.)
2003-02-01
Aspiration cover for the loading site of a belt conveyer
Energy Technology Data Exchange (ETDEWEB)
An aspiration cover is proposed for the site of loading a belt conveyer including a housing arranged above the belt conveyer in whose cover there is an aspiration sleeve and a discharge chute from the upper wall and a guide having a cushioning plate on the lower end. It is distinguished by the fact that in order to improve the effectiveness of removing dust by decreasing the volume of aspirated air, the cover between the aspiration sleeve and the upper wall of the loading chute is convex in the inside of the housing and has a smooth connection to the upper wall of the discharge chute turned towards the cushioning plate.
1982-01-01
Burning of droplets and particles of explosives
Energy Technology Data Exchange (ETDEWEB)
Small droplets of organic diazides investigated by C.K. Law and coworkers burn in hot gas at 1 atm with rates inversely proportional to the droplet diameter presumably owing to leading chemical reaction proceeds in gas phase. These burning rates are obviously much lower than those obtained by extrapolation of the results measured for the some substances in glass tubes (at pressure of about 10{sup -2}-10{sup -1} atm, and temperature 0-100 deg C) on the burning conditions of the droplets. Kinetic constants estimated using Zel`dovich equation for the burning rate in gas phase and Semenov relation for delay time of the droplets micro-explosion in liquid phase are about the same: E {approx_equal} 0.17 MJ/mol, log{sub 10}k{sub o} {approx_equal} 15(S{sup -1}). In both of the cases the leading chemical reaction is supposed to be of the first order. Landau instability is assumed to be reflected in distortion of the droplets at burning but, as opposed to ...
1996-12-31
Yttrium doped La_1_-_xY_xO_0_._9F_0_._1FeAs superconductors: Hall and thermopower studies
International Nuclear Information System (INIS)
The effect of yttrium substitution at the lanthanum site on the superconducting properties of La_1_-_xY_xO_0_._9F_0_._1FeAs ('x' = 0, 0.10, 0.20, 0.30, 0.50 and 0.60) oxypnictides has been studied. Powder X-ray diffraction studies confirm single phases till x = 0.1 beyond which minor amount of Y_2O_3 is observed. The temperature dependence of resistivity measurements confirm the superconducting transition temperature (T_c) of 34.8 (#+-#0.05) K and corresponding Meissner transition at 34.3 K in the 'x' = 0.3 composition which is higher than that reported for the parent phase (LaO_0_._9F_0_._1FeAs (T_c = 28 K)). Further increase in the concentration of yttrium leads to broadening and suppression of the superconducting transition. The value of H_c_2 at zero temperature is estimated to be about 60.5 T. The Seebeck coefficient (S) shows a negative sign indicating that the major contribution to the ...
2010-06-01
Screening Criteria for Loss of Room Cooling Failure
Energy Technology Data Exchange (ETDEWEB)
In this report, we estimated the temperature of the pump rooms and reviewed the operability of the components under the loss of the HVAC (Heating, Ventilation, and Air Condition) system. The issues relevant to the HVAC system in the PSA (Probabilistic Safety Assessment) FT (Fault Tree) model are as follows: (1) Does the loss of the HVAC system bring about a function failure of other components? (2) Can the operator take action to reduce the temperature of the room in case of a HVAC function failure? At present, we do not know whether a component will lose its function or not under the loss of the HVAC. ASME Standard describes that a recovery action can be credited if the related recovery action is included in the procedure or there are similar recovery experiences in the plant. However, there is no description about the recovery action of the HVAC in the EOP (Emergency Operation Procedure) of the UCN3, 4 under the situation ...
2007-01-15
Measurements of water vapor adsorption on the Geysers rocks
Energy Technology Data Exchange (ETDEWEB)
The ORNL high temperature isopiestic apparatus was adapted for adsorption measurements. The quantity of water retained by rock samples taken from three different wells of The Geysers was measured at 150 °C and at 200 °C as a function of pressure in the range 0.00 ≤ p/p0 ≤ 0.98, where p0 is the saturated water vapor pressure. The rocks were crushed and sieved into three fractions of different grain sizes (with different specific surface areas). Both adsorption (increasing pressure) and desorption (decreasing pressure) runs were made in order to investigate the nature and extent of the hysteresis. Additionally, BET surface area analyses were performed by Porous Materials Inc. on the same rock samples using nitrogen or krypton adsorption measurements at 77 K. Specific surface areas and pore volumes were determined. These parameters are important in estimating water ...
1996-01-24
Energy Technology Data Exchange (ETDEWEB)
Since the integrity of the containment penetrations was confirmed under accident management (AM) conditions in the former test, failure criteria tests and aerosol trapping tests were carried out using low-voltage modules and flange gaskets of an actual plant under severe accident (SA) conditions, without AM. The safety margin for failure temperature of the penetrations and the credit for fission product (FP) aerosol trapping effect along the leakage paths of the degraded penetrations were evaluated in the present tests. Failure temperature of the penetrations ranged from 270 to 300degC for low-voltage modules and 300 to 350degC for flange gaskets under 0.4 to 1.0 MPa conditions. Pressure dependency on failure temperature was small. This means that the safety margin of failure temperature under AM condition is more than 70degC. By introducing a equivalent leak area for the damaged test pieces, total leak ...
1999-07-01
Cask consolidated spent fuel thermal analyses using the COBRA-SFS code
Energy Technology Data Exchange (ETDEWEB)
The COBRA-SFS computer code was used to perform thermal-hydraulic analyses of consolidated spent fuel stored in casks. The ability of the COBRA-SFS code to model consolidated fuel was evaluated by comparing predictions with experimental data obtained from electrically heated rod bundles by Ridihalgh, Eggers, and Associates and Eggers Ridihalgh Partners, Inc. under sponsorship of the Electric Power Research Institute. The calculations agreed with the measured temperatures well within the bounds of experimental error. Based on the evaluation results, best-estimate temperature predictions were performed for consolidated fuel in several cask designs. Results are presented for the REA 2023 BWR cask, the CASTOR-1C BWR cask, and the Concrete Sealed Storage Cask designed for Monitored Retrievable Storage (MRS). The cask simulation results indicate that consolidation of spent fuel results in a reduction of convection and radiation ...
1986-04-01
WALL PRESSURE FLUCTUATIONS UNDER TURBULENT ...
... necessary to allow for the effata nr the finits size of the oressure tranaducer on both the root mean square and power spectral density measurements ...
1963-04-01
Strain Rate Effects on Ultimate Strain of Copper
... Figure 3a. PETN Filled Tube Specimen Detonated by Exploding Bridgewire Specimen POLYETIILLENE END-CAP "1- 901am WALL IHICKNESS ...
1979-05-01
Semi Annual Progress Report on BLADE END WALL FLOWS IN COMPRESSORS ...
Eckert, B., "Axial Kompressoren und Radial Kompressoren," Springer. Verlag, Berlin, 1953. 3. Lebot, Y., et al., "Theoretical and Experimental Determination ...
SPACE STATION INTEGRATED WALL DESIGN AND PENETRATION
screens of fine wire was placed between the gun barrel and the panel to determine whether the gun performance was repeatable. The transducers were placed ...
Review of Polyarylacetylene Matrices for Thin-Walled ...
... After strip- ping off the chloroform, the dibromo ethyl (EDBEB) compounds are separated from the m-BDBEB using a thin film evaporator. ...
1989-09-25
Pressure-induced structural transitions in multi-walled carbon nanotubes
British Library Electronic Table of Contents (United Kingdom)
We demonstrate a novel cross-sectional deformation, called the radial corrugation, of multi-walled carbon nanotubes (MWNTs) under hydrostatic pressure. Theoretical analyses based on the continuum elastic approximation have revealed that MWNTs consisting of more than ten concentric walls undergo elastic deformations at critical pressure Formula Not Shown , above which the circular shape of the cross-section becomes radially corrugated. Various corrugation modes have been observed by tuning the innermost tube diameter and the number of constituent walls, which is a direct consequence of the core-shell structure of MWNTs. Cross-sectional views of MWNT under high hydrostatic pressure: elliptic deformation with the mode index n = 2 (left), and radial corrugations with n = 5 (center), and n = 6 ...
2009-01-01
Neural Tissues from the Implanted Stem Cells
International Science & Technology Center (ISTC)
Morphological, Electrophysiological and Behavioral Investigations of the Nervous Tissue Developed from the Embryonic Matrix Zone Cells of the Dorsolateral Walls of Lateral Ventricles, Implanted into the Lesioned Regions of the Adult Rat's Brain
Mechanical jacks meant to support the movable shielding wall (Proton Room side) of the SC
This mechanical version was soon after changed into a hydraulic jack one (the reason being a number of serious constructional defects).
1955-01-01
Magnetohydrodynamic structure of a plasmoid in fast ... - NASA
We set a symmetric boundary at x=200 and a conducting wall at z=150. The domain of 0200. 0150 is resolved by 60004500 grid cells. Harris sheet ...
... 2.2.1 Polymerization of DVB Under Pressure DVB was polymerized at 300*C in thin-walled Pd-Ag capsules at pressures up to 60,000 psi. ...
1972-07-27
Fractional domain walls from on-site softening in dipolar bosons
We study dipolar bosons in a 1D optical lattice and identify a region in parameter space---strong coupling but relatively weak on-site repulsion---hosting a series of stable CDW states whose low-energy excitations, built from "fractional domain walls", are remarkably similar to those of non-abelian fractional quantum Hall states. Here, a conventional domain wall between translated CDW's may split by inserting strings of degenerate, but inequivalent, CDW states. Outside these insulating regions, we find numerous supersolids as well as a superfluid regime. The mentioned phases should be accessible experimentally, and in particular, the fractional domain walls can be created in the ground state using single-site addressing, i.e. by locally changing the chemical potential.
2011-01-01
Elastodynamics of vehicles and crash simulation
Energy Technology Data Exchange (ETDEWEB)
Accidents of free-rolling cars against walls with friction are special cases of the general problem of the dynamic behavior (elastic or plastic) of car motion. Using particle modeling of the car body it is shown that large rotations, contact friction and plastic deformations can be computed. Because of the limitations of FEM it is necessary to model the car as a system of mass points connected by central force systems which are non-linear. The wall is formulated as a rigid body producing constraints for the contacting particles, while the contact force is given by the defined force system. Every contacting particle produces a plastic impact on the wall. The friction force is proportional to the contact force and lies in the direction of the sliding velocity on the wall. Time integration is carried out using a second order Gear method. ((orig.))
1994-09-30
DESIGN OF A CONVECTIVE COOLING SYSTEM FOR A MACH 6 - NASA ...
Figure 23 presented detailed layout of the cooling system designed for the Mach 6 hypersonic- transport. The distribution system consisted of thin-wall ...
Analysis of Rough Wall Turbulent Heating with Application to ...
... roughness. Since T u'v' and q v'"F the heat transfer augmentation is the square root of the skin friction augmentation: - 1/2 (( St - ,Cf 0 ...
1979-01-01
Protein isolated from hen egg-white and functions as a bacteriostatic enzyme by degrading bacterial cell walls. First enzyme ever characterized by protein ...
International Nuclear Information System (INIS)
The COSA II (computer codes for salt) benchmark problem has been pursued with the ADINA (Automatic Dynamic Incremental Nonlinear Analysis) program code. With the use of this, the code should be validated by means of experimental data and the ability to reproduce real-life calculation results of the KfK (Kernforschungszentrum Karlsruhe/Nuclear Research Center in Karlsruhe) should be proven. A successful validation of the code then forms the foundation stone for the ability to use different calculation problems in the final (ultimate) storage. This also accompanies the consequent reaction of replacing the STEALTH (Solids and Thermal Hydraulics Code for EPRI Adapted from LAGRANGE TOODY and HEMP) program which has a number of program-specific weaknesses compared to the ADINA computer code. In order to reproduce the approximate values from the KfK, the same values have been used. Differences were evident in the discretion and the selection of the initial values for pressure and ...
The compressive strength of cement blocks permeated with an organic phase change material
Energy Technology Data Exchange (ETDEWEB)
The authors investigate the feasibility of constructing walls and partitions with enhanced heat storage capability from cement blocks permeated with an organic phase change material (pressed stearic acid). The blocks are lightweight, easy to produce and are cured in the same way as cement or concrete. The ratio of components (cement, stearic acid (SA) and water) was optimized with respect to compressive strength. With normal portland cement, the best compressive strength 2.2 MPa was obtained with a ratio C:SA:W of 1:0.8:0.65 (i.e. 32% stearic acid) after 28 days of curing. This was increased to 4.4 MPa when high early strength cement was used, about as strong as Sipporex, lightweight concrete or lightweight clay bricks. As expected, the compressive strength decreased linearly with temperature between 25/sup 0/C and 100/sup 0/C, at a rate of 15 kPa//sup 0/C. The drying shrinkage of the modules was found to be 50% greater than for cement mortars. ...
1984-01-01
T-HEMP3D, 3-D Time-Dependent Elastic Plastic Flow
International Nuclear Information System (INIS)
1 - Description of program or function: T-HEMP3D (Transportable HEMP3D) is a derivative of the STEALTH three-dimensional thermodynamics code developed by Science Applications, Inc. Changes were made primarily in three areas: material specification, coordinate generation, and the addition of sliding surface boundary conditions. STEALTH itself is based entirely on the HEMP3D code written at LLNL. HEMP3D solves problems in solid mechanics involving dynamic plasticity and time-dependent material behavior and problems in gas dynamics. 2 - Method of solution: The equations of motion, conservation equations, and constitutive relations for stresses, strains, hydrostatic pressure, the von Mises yield condition, and artificial viscosity are solved by finite difference methods following the format of the HEMP code (NESC Abstract 775). The physical object is divided into zones defined by 8 grid points. The grid (i,j,k) moves with the material, and the mass within a zone remains constant. HEMP3D is ...
Properties of SiC/SiC joining s and coatings for fusion
International Nuclear Information System (INIS)
Full text of publication follows: As SiCf/SiC composites are very low activation materials, their use as structural material for the reactor blanket and first wall components appears essential to demonstrate the potential of D-T fusion power reactor. Positive features of SiCf/SiC are their high performances at elevated operating temperature and the ability to produce a specific component. Critical issues of SiCf/SiC are the mechanical properties, radiation stability and, with regard to technological issues, their hermeticity and joining processes. Improvement of joining processes for SiC/SiC components is also needed. Recently, several blanket designs have been studied: the TAURO blanket concept in the European Union, the ARIESAT concept in the US and the DREAM concept in Japan. In those reactors, hermetic SiCf/SiC or self-sealing coatings are mandatory. The basic idea of self sealing concept is to manufacture a coating with specific ...
2007-12-10
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
