Torsional responses of double-walled carbon nanotubes via molecular dynamics simulations
Energy Technology Data Exchange (ETDEWEB)
The buckling behaviors of double-walled carbon nanotubes (DWCNTs) under torsion are investigated by using molecular dynamics (MD) simulations. The effect of length on the torsional buckling behaviors of DWCNTs is examined for the first time. The simulation results show that the DWCNTs experience gradual or simultaneous buckling deformations depending on their lengths. In addition, the effect of the inner tube in a DWCNT on its torsional buckling behavior is also examined. The presence of the inner tube triggers van der Waals (vdW) interactions between it and the outer tube and thus leads to a stiffening effect of the DWCNT against torsional deformation. Whether the ends of the inner tube are free or fixed and whether it is subject to a torque or not, the critical torque and the critical torsional angle of the outer tube are only marginally affected.
2008-11-12
Buckling and ultimate capability of plates and stiffened panels in axial compression
British Library Electronic Table of Contents (United Kingdom)
This paper presents extensive non-linear finite element (FE) analysis and formulation development work carried out on the ultimate compressive strength of plates and stiffened panels of ship structures. A review of contemporary designs for large ships was carried out. The existing formulae for plate ultimate compressive strength were reviewed and compared with non-linear FE analysis results. A semi-analytical formula for ultimate compressive strength assessments of stiffened panels was proposed and is described. The developed formula was verified against results using ABAQUS non-linear FE software for a series of 61 stiffened panels and a good agreement between the proposed formula and FE results were achieved. The method was verified against a large number of published FE results and was ...
2009-01-01
The paper investigates the effect of the wall heat flux ratio on the local heat transfer augmentation in a square channel with two opposite in-line ribbed walls for Reynolds numbers from 15,000 to 80,000. The square channel composed of 10 isolated copper sections has a length-to-hydraulic diameter ratio of 20. The rib height-to-hydraulic diameter ratio is 0.0625 and the rib pitch-to-height ratio equals 10. Six ribbed side to smooth side wall heat flux ratios are studied for four rib orientations. The results show that the ribbed side wall heat transfer augmentation increases with increasing ribbed side to smooth side wall heat flux ratios, but the reverse is true for the smooth side wall heat transfer augmentation. The average heat transfer augmentation of the ribbed side and smooth side wall ...
1992-10-01
Energy Technology Data Exchange (ETDEWEB)
The experimental survey about the heat transfer between the working fluid and the combustion chamber wall with a direct injection diesel engine has shown the production of a soot layer with increasing loads on the combustion chamber wall. Because the combustion process of methanol occurs without the formation of wall deposits, the same engine spark ignitioned with methanol at the same conditions has shown a higher heat transfer coefficient. Because the heat losses do not only depend on the heat transfer coefficient but also on the driving temperature difference between the working fluid and the combustion chamber wall, the methanol engine with corresponding process management showed lower heat losses than the diesel engine at nearly the same load. (orig./HW)
1994-04-01
Dispersoid separation method and apparatus
Energy Technology Data Exchange (ETDEWEB)
Improved separation of heavier material from a dispersoid of gas and heavier material entrained therein is taught by the method of this invention which advantageously uses apparatus embodied in an inertial separator having rotary partition means comprising wall members dividing a housing into a plurality of axially-extending through passages arranged in parallel. Simultaneously with the helical transit of a moving stream of the dispersoid through the parallel arrangement of axially-extending through passages at a constant angular velocity, the heavier material is driven radially to the collecting surfaces of the rotational wall members where it is collected while the wall members are rotating at the same angular velocity as the moving stream. The plurality of wall members not only provides an increased area of collecting surfaces but the positioning of each of the ...
1980-01-01
UK PubMed Central (United Kingdom)
Partial bladder outlet obstruction (PBOO) induces remodeling of urinary bladder smooth muscle (detrusor). We demonstrate an increase in bladder wall mass, muscle bundle size, and a threefold increase...Full Text Available
2004-02-01
Energy Technology Data Exchange (ETDEWEB)
It is postulated that a break of a thin-walled pipe does not cause a subsequent break in the pipe in the vicinity of a plastic hinge even when the wall is weakened by a 60 circumferential crack of a depth of 30% of the wall thickness on the tension side. This pipe behavior is the result of plastic buckling in the compression side and applies to pipes of diameter-to-thickness ratio larger than 20. For this type of pipe, the axial strains decrease with increasing diameter-to-thickness ratio in the tension side. As the pipe is only loaded in one direction, there is no cyclic behavior that can trigger a subsequent break. (orig.)
1993-10-01
Energy Technology Data Exchange (ETDEWEB)
To assess the potential of CT in evaluating the histological severity of acute appendicitis in comparison with surgical and pathological findings. The CT images of 75 patients with surgically proven appendicitis, including 10 cases of catarrhal, 34 of phlegmonous, and 31 of gangrenous appendicitis, were retrospectively analyzed for the following five CT findings: hazy periappendiceal densities, enlarged appendix, increased enhancement of the appendiceal wall, increased enhancement of the periappendiceal intestinal wall, and deficiency of the appendiceal wall. By comparing all the CT findings and the pathological severity of appendicitis (catarrhal, phlegmonous, and gangrenous), the prevalence of the five CT findings was calculated for each pathological category. Abnormal CT findings were noted in only one case of catarrhal appendicitis. Increased enhancement of ...
2001-08-01
Turbulent heat transfer augmentation using microscale disturbances inside the viscous sublayer
Energy Technology Data Exchange (ETDEWEB)
The authors report here on an experimental study of heat transfer augmentation in turbulent flow. Enhancement strategies employed in this investigation are based on the near-wall mixing processes induced in the sublayer through appropriate wall and near-wall streamwise-periodic disturbances. Experiments are performed in a low-turbulence wind-tunnel with a high-aspect-ratio rectangular channel having either (a) two-dimensional periodic microgrooves on the wall, or (b) two-dimensional microcylinders placed in the immediate vicinity of the wall. It is found that microdisturbances placed inside the sublayer induce favorable heat-transport augmentation with respect to the smooth-wall case, in the near-analogous momentum and heat transfer behavior are preserved; a roughly commensurate increase in heat and momentum transport is termed favorable in ...
1992-05-01
The L-type calcium channel inhibitor diltiazem prevents cardiomyopathy in a mouse model
UK PubMed Central (United Kingdom)
Dominant mutations in sarcomere protein genes cause hypertrophic cardiomyopathy, an inherited human disorder with increased ventricular wall thickness, myocyte hypertrophy, and disarray. To understand...Full Text Available
2002-04-15
Radiation modification of vascular prostheses
International Nuclear Information System (INIS)
The radiation method has been employed for the modification of the surface of vascular prostheses by means of acrylamide. As a result of the treatment, the tightness of the prosthesis walls was improved as well as an increase of surface hydrophilicity. Upon autoclaving, stable binding of polyacrylamide to prostheses is achieved. (author).
UK PubMed Central (United Kingdom)
We report a case of 38-year-old male, who presented with a large pulsatile swelling on the left side of the anterior chest wall of 4 months’ duration with a gradual increase in size. He gave...Full Text Available
2010-07-01
Increased endothelial and vascular smooth muscle cell adhesion on nanostructured titanium and CoCrMo
UK PubMed Central (United Kingdom)
In the body, vascular cells continuously interact with tissues that possess nanostructured surface features due to the presence of proteins (such as collagen and elastin) embedded in the vascular wall....Full Text Available
2006-03-01
UK PubMed Central (United Kingdom)
The incidence of arrhythmias after acute myocardial infarction of the inferior wall varies with the affected segment and increases when there is right ventricular involvement. This paper provides a...Full Text Available
2009-01-01
Multi-scale modeling of fiber and fabric reinforced cement based composites
With an increased use of fiber reinforced concrete in structural applications, proper characterization techniques and development of design guides are needed. This dissertation presents a multi-scale modeling approach for fiber and fabric reinforced cement-based composites. A micromechanics-based model of the yarn pullout mechanism due to the failure of the interfacial zone is presented. The effect of mechanical anchorage of transverse yarns is simulated using nonlinear spring elements. The yarn pullout mechanism was used in a meso-scale modeling approach to simulate the yarn bridging force in the crack evolution process. The tensile stress-strain response of a tension specimen that experiences distributed cracking can be simulated using a generalized finite difference approach. The stiffness degradation, tension stiffening, crack spacing evolution, and crack width characteristics of cement composites can be derived using matrix, interface and ...
2008-01-01
Four loss-of-flow accidents in the SEAFP first wall/blanket cooling system
Energy Technology Data Exchange (ETDEWEB)
This report presents the thermal-hydraulic analysis of four Loss-of-Flow Accidents (LOFAs) in the first wall/blanket cooling system of the alternative SEAFP reactor design. The LOFAs considered result from a loss of electrical power for the recirculation pump in the primary cooling circuit. The analyses have been performed using the thermal-hydraulic system analysis code RELAP5/MOD3. In the analyses, special attention has been paid to the transient thermal-hydraulic behaviour of the cooling system and the temperature development in the first wall and blanket. For the LOFA without plasma shutdown, significant loss of heat removal due to dryout occurs at the midplane of the outboard first wall cooling pipes about 41 s after pump trip. For the three LOFA cases with emergency plasma shutdown that have been studied, the temperature increase in the Be-coating at the midplane of the outboard first ...
1994-07-01
Energy Technology Data Exchange (ETDEWEB)
The unburned HC in a direct-injection diesel engine is a cause of exhaust odor and SOF emission. Reduction of HC by changing the injection nozzle specifications was attempted in previous studies. In this study, some experiments in which the mixture formation was varied by using different hole diameters in a multihole nozzle and spray angles to the combustion chamber wall have been conducted. When the diameter of injection holes, which influences the fuel adhering to on the cylinder head walls and the combustion chamber wall, becomes smaller, the HC emission in the idling condition, HC deviation from cylinder to cylinder and HC increase with long idling time are decreased. The same effects were obtained by decreasing the diameter of all holes and by injecting the spray downward to the combustion chamber. 13 refs., 13 figs., 1 tab.
1996-02-25
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study is to identify the radiative heat transfer augmentation by a coaxial cylinder introduced in the infinite cylindrical pipe enclosing a participating gas. The gas is either a mixture of water vapor and carbon dioxide or gray. The gas is assumed to be homogeneous at a constant temperature, and has a refractive index of unity. All of the surfaces are opaque and gray, diffusely emitting and reflecting at a constant temperature. The effect of system diameter, diameter ratio, wall emittances, gas and surface temperatures, mixture component on heat transfer augmentation are studied by using the zone method with participating gas radiative properties evaluated from the weighted sum of gray gases model. From the radiative equilibrium condition, the installed wall temperature is formulated and calculated by the iteration method. If the medium is a gray gas, the augmentation observed are negligible. For the range of values studied ...
1992-10-01
Effect of electron irradiation on domain wall pinning defects in 50-50 NiFe
International Nuclear Information System (INIS)
A magnetic measuring technique, which sorts out defects according to a distribution function n, was used to study the influence of electron irradiation on 50-50 NiFe. The distribution function is determined in terms of the maximum force f/subm/ that a defect can exert on a forward moving domain wall, or equivalently, the range z_0, which is the distance the mean position of the wall may move past the defect before the wall snaps free from the pinning action of the defect. The range and maximum force are related by a spring constant k, viz., f/subm/=kz_0. The quantity n (z_0) dz_0 gives the number of defects per unit volume having a range between z_0 and z_0+dz_0. Distribution functions were determined before and after electron irradiation. The irradiation was for 100 min with 18-MeV electrons with a dose of 1.1times10"1"7 e/cm"2. Following irradiation, there was a substantial decrease in the number of short-range defects ...
British Library Electronic Table of Contents (United Kingdom)
Cyclothiazomycin B1 (CTB1) is an antifungal cyclic thiopeptide isolated from the culture broth of Streptomyces sp. HA 125-40. CTB1 inhibited the growth of several filamentous fungi including plant pathogens along with swelling of hyphae and spores. The antifungal activity of CTB1 was weakened by hyperosmotic conditions, and hyphae treated with CTB1 burst under hypoosmotic conditions, indicating increased cell wall fragility. CTB1-sensitive fungal species contain high levels of cell wall chitin and/or chitosan. Unlike nikkomycin Z, a competitive inhibitor of chitin synthase (CHS), CTB1 did not inhibit CHS activity. Although CTB1 inhibited CHS biosynthesis, the same result was also obtained with a non-specific proteins inhibitor, cycloheximide, which did not reduce cell wall rigidity. These ...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The need to increase efficiency of volumetric receivers for use in solar power plants by reducing reradiation losses and increasing the ``volumetric effect`` has promoted the idea of a receiver with tapered ducts. These seems to be very promising since higher efficiency and considerable saving of material can be achieved, as compared to conventional receivers perforated with ducts of constant cross-section. A finite element program is being developed to calculate stationary heat transfer in the tapered ducts by free and forced convection in the gas flow, conduction in walls and in the gas, and solar and thermal radiation. Gas and wall temperatures are considered to be varying only in the flow direction. In order to perform the highly nonlinear calculations of radiative exchange, the exact knowledge of the view factors is necessary. The aim of the present work is to evaluate analytically the view factors ...
1995-02-01
Structural and magnetic studies on the enhancement of the giant magnetoimpedance by ion irradiation
British Library Electronic Table of Contents (United Kingdom)
The mechanism of abrupt increase of the giant magneto impedance (GMI) ratio in the ion irradiated Co-based amorphous ribbon has been investigated. The grazing incident X-ray diffraction and transmission electron microscope were used to characterize the samples before and after ion irradiation. The GMI-ratio considerably increased in the ion irradiated samples and the GMI response showed strong dependence on the driving frequencies. The Barkhausen noise (BN) signals are increased for the Ar ion irradiated sample with dose of 1x10^1^7 ion/cm^2. The results are interpreted in terms of GMI variation associated with domain wall dynamics.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The process operation of the hot wall vapor deposition method, formation of dry organic thin film and the control of molecular arrangement were described. This equipment included a substrate on the upper end of the hot wall tube and the vapor source at the lower end. The remarkable features are the hot wall tube which plays the role to hold vaporizing molecules to the high temperature and to transport molecules, and the flip flop mechanism which gives some idle period for the molecular vaporization by shutter closing. Several experiments were carried out by using stearic acid and by changing the distance S from the upper end of hot wall quartz tube to the substrate, the furnace temperature T{sub f} and the substrate temperature T{sub s}. When T{sub f} is equal to or less than the melting point of stearic acid, molectles are preferentialy made to vertical arrangement. In the case of T{sub f} more than ...
1991-12-01
Solids are separated from a liquid in a gravity settler provided with inclined solid intercepting surfaces to intercept the solid settling path to coalesce the solids and increase the settling rate. The intercepting surfaces are inverted V-shaped plates, each formed from first and second downwardly inclined upwardly curved intersecting conical sections having their apices at the vessel wall.
1979-01-01
British Library Electronic Table of Contents (United Kingdom)
A highly sensitive and stable tris(2,2prime-bipyridyl)ruthenium(II) (Ru(bpy)32+) electrogenerated chemiluminescence (ECL) sensor was developed based on carbon nanotube (CNT) dispersed in mesoporous composite films of sol-gel titania and perfluorosulfonated ionomer (Nafion). Single-wall (SWCNT) and multi-wall carbon nanotubes (MWCNT) can be easily dispersed in the titania-Nafion composite solution. The hydrophobic CNT in the titania-Nafion composite films coated on a glassy carbon electrode certainly increased the amount of Ru(bpy)32+ immobilized in the ECL sensor by adsorption of Ru(bpy)32+ onto CNT surface, the electrocatalytic activity towards the oxidation of hydrophobic analytes, and the electronic conductivity of the composite films. Therefore, the present ECL sensor based on the CNT-...
2006-01-01
Multi walled carbon nanotubes/epilson polylysine nanocomposite with enhanced antibacterial activity
British Library Electronic Table of Contents (United Kingdom)
Abstract Aims: To develop a new nano composite of multi walled carbon nanotubes (MWNTs) with enhanced antimicrobial activity. Methods and Results: A novel antimicrobial nanocomposite [MWNT epilson polylysine (MEPs)] was synthesized via covalent attachment of epilson polylysine on MWNTs with hexamethylene diisocyanate (HDI) as the coupling agent. UV visible spectra and Fourier transform infrared spectra (FT IR) investigations indicate that MEPs is stable, with epilson polylysine leaching effectively eliminated. When compared to MWNTs, the new nano composite MEPs exhibits enhanced antimicrobial activities. In 20 mg l 1 suspensions, significant increases of 72 1, 64 5 and 69% against Escherichia coli, Pseudomonas aeruginosa and Staphylococcus aureus can be observed. The deposited film of MEPs...
2011-01-01
Lorentz transmission electron microscopy investigation of magnetically patterned Co/Pt multilayers
Energy Technology Data Exchange (ETDEWEB)
The switching behavior of magnetic patterns prepared by ion irradiation was investigated. Co/Pt multilayers with perpendicular anisotropy and large out-of-plane coercivities 5-6 kOe were grown on electron transparent SiN windows. Regularly spaced 1 micron sized regions, were magnetically pattered via ion beam irradiation through a stencil mask. Lorentz TEM was used to observe in-situ magnetization reversal processes of irradiated regions under well-defined applied magnetic fields. When the in-plane field was increased, domain wall motion was observed, resulting in the alignment of the patterns with the direction of the applied field. The switching mechanism of the in-plane patterns was by domain wall motion.
2000-08-01
Causes of poor sealant performance in soil gas resistant foundations
International Nuclear Information System (INIS)
The surface permeability of concrete walls and floors in houses was measured with a specially designed permeameter, based on measuring the air-flow induced by a pressure difference across a temporary test seal applied to a surface. The permeability of bulk concrete is 10"-"1"6 m"2. Areas free of surface defects had permeability ranging from 10"-"1"4 to 10-"1"6 m"2. However, surface defects are common on concrete wall surfaces, which increase the permeability to >10"-"1"2 m"2. This is too high for standard seal designs to be adequate as the only method of soil gas and radon exclusion. Satisfactory seals require either extended contact width or mechanical removal of the surface layer. (orig.). (2 figs., 1 tab.).
1993-07-04
Wall thinning trend analyses for secondary side piping of Korean NPPs
International Nuclear Information System (INIS)
Since the mid-1990s, nuclear power plants in Korea have experienced wall thinning, leaks, and ruptures of secondary side piping caused by flow-accelerated corrosion (FAC). The pipe failures have increased as operating time progresses. In order to prevent the FAC-induced pipe failures and to develop an effective FAC management strategy, KEPRI and KOPEC have conducted a study for developing systematic FAC management technology for secondary side piping of all Korean nuclear power plants. As a part of the study, FAC analyses were performed using the CHECWORKS code. The analysis results were used to select components for inspection and to determine inspection intervals on each nuclear power plant. This paper describes the introduction of the FAC analysis method and the wall thinning trend analysis results by reactor type, system, and water treatment amine. This paper also represents the site application feasibility for ...
2003-08-17
Energy Technology Data Exchange (ETDEWEB)
Discussions were given on the characteristics of a diesel engine to emit unburned hydrocarbon (HC) created in a long idling operation. The engine tested in the experiment is a direct injection diesel engine with six water-cooled were investigated varying the jet hole diameter and length of the jet nozzle. In the initial operation period, the HC showed high values. This is thought because part of the injected fuel has deposited on the wall because of low combustion chamber wall temperature, and the fuel deposit that did not evaporate during combustion evaporated during expansion process and emitted unburned. The head was dismantled to investigate the carbon flowers deposited on the nozzle and the relationship between the carbon and the HC deposited on the head face and the combustion chamber wall. It was clarified that the HC increase was phenomenal compared with that of the carbon. This is because the ...
1992-04-01
Test Bed for Superconducting Materials
Energy Technology Data Exchange (ETDEWEB)
Superconducting rf cavities are increasingly used in accelerators. Gradient is a parameter of particular importance for the ILC. Much progress in gradient has been made over the past decade, overcoming problems of multipacting, field emission, and breakdown triggered by surface impurities. However, the quenching limit of the surface magnetic field for niobium remains a hard limitation on cavity fields sustainable with this technology. Further exploration of materials and preparation may offer a path to surpassing the current limit. For this purpose, we have designed a resonant test cavity. One wall of the cavity is formed by a flat sample of superconducting material; the rest of the cavity is copper or niobium. The H field on the sample wall is 75% higher than on any other surface. Multipacting is avoided by use of a mode with no surface electric field. The cavity will be resonated through a coupling iris with high-power rf ...
2006-01-30
Recent developments in the design of conceptual fusion reactors
International Nuclear Information System (INIS)
Since the first round of conceptual fusion reactor designs in 1973 - 1974, there has been considerable progress in design improvement. Two recent tokamak designs of the Wisconsin and Culham groups, with increased plasma beta and wall loading (power density), lead to more compact reactors with easier maintenance. The Reference Theta-Pinch Reactor has undergone considerable upgrading in the design of the first wall insulator and blanket. In addition, a conceptual homopolar energy storage and transfer system has been designed. In the case of the mirror reactor, there are design changes toward improved modular construction and ease of handling, as well as improved direct converters. Conceptual designs of toroidal-multiple-mirror, liner-compression, and reverse-field pinch reactors are also discussed. A design is presented of a toroidal multiple-mirror reactor that combines the advantages of steady-state operation and ...
Evaluation of pipe whip impacts on neighboring piping and walls of the Ignalina Nuclear Power Plant
Energy Technology Data Exchange (ETDEWEB)
Stress corrosion cracks have been discovered in Group Distribution Headers (GDH) at the Ignalina and Chernobyl Nuclear Power Plants. This increases the probability that a guillotine pipe break can occur that creates a whipping pipe (GDH) with the potential to damage surrounding structures-i.e. adjacent GDH and its attached piping or adjacent reinforced concrete compartment wall. The GDH is the most important component for reactor safety in case of an accident. Emergency Core Cooling System (ECCS) piping is connected to the GDH piping such that, during an accident, coolant passes from the ECSS into the GDH. Presented in this paper is the transient analysis of a Group Distribution Header following a guillotine break at the blind end of the header. Using a very conservative force loading function, the transient response of a whipping RBMK-1500 GDH along with neighboring concrete walls and pipelines is obtained using finite ...
2007-04-15
Results and recommendations from studies of basic handling characteristics of solid biomass fuels
Energy Technology Data Exchange (ETDEWEB)
Main results are summarised for a project carried out with the aim of increasing the knowledge of relations between handling characeristics and properties such as moisture content, particle size and shape etc. Handling characteristics that were studied: angle of repose, friction between fuel and different surfaces, the fuel`s tendency to bridge across openings, and its freezing characteristics. Some forty solid biomass fuels were studied, mainly wood fuels, with particle sized from 1 to 200 mm. New methods were developed for measurement of bridging across openings and freezing characeristics. The angle of repose varied between 25 and 55 deg. The particle shape had a significant influence, a high ratio of length/thickness gave a high angle of repose. When the fuel moisture content was increased the angle of repose first increased, then decreased, and finally increased again. The particle size had no ...
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
Multi-walled carbon nanotubes (MWNTs) were modified with poly(hexamethylene adipamide) (also known as Nylon 66) via a controlled polymer solution crystallization method. A 'nanohybrid shish kebab' (NHSK) structure was found wherein the MWNT resembled the shish while Nylon 66 lamellar crystals formed the kebabs. These Nylon 66-functionalized MWNTs were used as precursors to prepare polymer/MWNT nanocomposites. Excellent dispersion was revealed by optical and electron microscopies. Nitric acid etching of the nanocomposites showed that MWNT formed a robust network in Nylon 66. Non-isothermal DSC results showed multiple melting peaks, which can be attributed to lamellar thickness changes upon heating. The crystallite sizes L{sub 100} and L{sup 010} of Nylon 66, determined by WAXD, decreased with increasing MWNT contents. Isothermal DSC results showed that crystallization kinetics increased first and then ...
2007-01-01
Fracture characterizatioin of the Bandelier tuff in OU-1098 (TA-2 and TA-41)
Energy Technology Data Exchange (ETDEWEB)
Rock fracture characterization documents a total of 1496 fractures in unit 2 of the Tshirege Member of the Bandelier Tuff along 6013 feet of Los Alamos Canyon`s north wall adjacent to Operational Unit 1098. Geologically termed joints, these fractures likely owe their primary origin to brittle failure during the cooling contraction of the tuff after its emplacement nearly 1 million years ago. Subsequent tectonic movement along the Pajarito Fault system has modified fracture strikes, dips, apertures, and linear density. From a background linear density of approximately 20 fractures per 100-foot interval along the canyon wall, fracture density increases to values in excess of 50 fractures per 100-foot interval in a zone at and immediately east of the Omega West reactor building TA-2-1. This increase in fracture density is coincident with the mapped trace of the Guaje Mountain Fault (GMFZ) that apparently ...
1996-10-01
Ideal Magnetohydrodynamics Stability Spectrum with a Resistive Wall
Energy Technology Data Exchange (ETDEWEB)
We show that the eigenvalue equations describing a cylindrical ideal magnetophydrodynamicsw (MHD) plasma interacting with a thin resistive wall can be put into the standard mathematical form: ??? = ??? ?. This is accomplished by using a finite element basis for the plasma, and by adding an extra degree of freedom corresponding to the electrical current in the thin wall. The standard form allows the use of linear eigenvalue solvers, without additional interations, to compute the complete spectrum of plasma modes in the presence of a surrounding restrictive wall at arbitrary separation. We show that our method recovers standard results in the limits of (1) an infinitely resistive wall (no wall), and (2) a zero resistance wall (ideal wall).
2008-05-22
Numerical simulation of a 1200 MWth pulverised fuel oxy-firing furnace
Energy Technology Data Exchange (ETDEWEB)
The Oxycoal burner for pulverised coal combustion previously developed by the authors has been scaled up to typical power plant dimensions and a CFD study of pulverised coal combustion in a 1200 MWth oxy-firing furnace has been performed. The study revealed the importance of modelling the flue gas radiation behaviour for flue gas temperatures and wall heat transfer. This was done using a non-grey implementation of the Exponential Wide Band Model (EWBM). Typically, comparisons between air and oxy-fired furnaces point out that to obtain similar flame behaviour, the oxygen content in oxy-firing conditions should be increased until the same adiabatic flame temperature is reached. However, it was found that for these conditions, significantly increased wall heat fluxes can be the result. Furthermore, at gas temperatures comparable to air combustion, particle burnout is accelerated in oxy-firing due to the ...
2009-07-01
Energy Technology Data Exchange (ETDEWEB)
Electrification of Teflon (PTFE) particles pneumatically transported while repeating collision with the wall is different from the cases of nylon 66 or PMMA. PTFE is known as negatively charging substance. Extremely little electrification was found when vertically colliding to the wall. By experiments, it was found that: 1. In the case of vertical collision, electrification was extremely low. 2. Chareg amount by collision increases as v cos increases when it is less than 7.5 m/s in a condition that a horizontal component of a collision speed is present. When v cos is more than 7.5 m/s, the charge approaches that of vertical collision. 3. Measured value of collision area roughly coincided with the result of calculation using an equation based on the assumption that the deforamtion depended only on the vertical component of the collision speed. 4. Charge density gets larger for less v cos and more v sin . ...
1990-07-31
Energy Technology Data Exchange (ETDEWEB)
The influences of compressive stress on the dielectric properties of (1 - x)Pb(In{sub 1/2}Nb{sub 1/2})O{sub 3}-xPbTiO{sub 3} (x = 0.1-0.5) ceramics was investigated in this study. The dielectric properties were measured under compressive stress applied parallel and perpendicular to electric field. The results clearly showed that the superimposed compression stress had pronounced effects on the dielectric properties of PIN-PT ceramics. In general, with increasing compressive stress the dielectric constant of the ceramics increased and decreased when the stress was applied parallel and perpendicular, respectively, to the electric field direction. The dielectric loss tangent, however, decreased in both stress cases. The observations were mainly interpreted in terms of competing influences of the domain switching through non-180 deg. domain walls, clamping of domain walls, de-ageing and the stress-induced ...
2008-04-21
Analysis of natural convection in narrow annular gaps of LMFBR
International Nuclear Information System (INIS)
The natural convection characteristics of gas in a vertical narrow annular gap which had its bottom opened to high temperature fluid and its upper shielding exposed to low temperature sealant have been evaluated from simulated fluid experiments using water and from calculations using the three-dimensional thermal hydraulic analysis computer code THERVIS-III. The following results were obtained: (1) The critical Rayleigh number which represented the limit of convection generation increased as the aspect ratios #epsilon#_1 (height/circumference) and #epsilon#_2 (height/gap distance) increased. (2) The flow pattern along the circumferential direction was seen to depend more strongly on the radiant heat from the side wall, rather than the aspect ratios #epsilon#_1 and #epsilon#_2. (3) The temperature difference along the circumferential direction in the annular gap obtained from the calculation code coincided with that obtained ...
Energy Technology Data Exchange (ETDEWEB)
Fe-Cr-Mn stainless steel is one of the candidate materials for the 1`st wall materials and structural applications of fusion reactor as regards reduced radioactivation properties than Fe-Cr-Ni austenitic stainless steels. This report deals with the effects of annealing and aging heat treatment on the microstructure, mechanical properties and corrosion resistance of Fe-Cr-Mn alloys varying Mn and W contents, which were made using vacuum high frequency induction furnace. Increasing Mn contents, austenite phase was increased, and maximum .epsilon. martensite phase was formed at about 21% Mn. W-addition made small amount of ferrite phase in the matrix, and the ferrite contents were increased with raising annealing temperature. Increased Mn contents reduced tensile stress and yield stress but increased the elongation. W-addition raised the high temperature tensile ...
1996-07-01
Vortex generator induced heat transfer augmentation past a rib in a heated duct air flow
Energy Technology Data Exchange (ETDEWEB)
The present investigation represents the initial phase of a comprehensive experimental program designed to study the potential for increasing the heat transfer per unit pressure drop in a ribbed duct by positioning vortex generators at key locations in the flow. In particular, the present investigation consists of a rib positioned at the inlet to a rectangular test section with uniform heating at its bottom wall. Local and average Nusselt number results are obtained for a circular rod positioned either immediately above or just downstream of the rib.
1992-02-01
Thermally developing flow in curved square ducts with internal fins
Energy Technology Data Exchange (ETDEWEB)
The laminar incompressible hydrodynamically fully developed and thermally developing flow is studied in a curved square duct with four longitudinal fins. The duct is successively subjected to constant wall temperature, to circumferentially uniform temperature and axially linearly or exponentially varying temperature. The local and fully developed Nusselt numbers are examined for various values of the Dean number and it is found that the heat transfer rate increases for high fins. The parameters that affect the entry length are studied and the fluctuations of the local Nu that appear in the entrance region are investigated. Temperature contour plots are presented for the visualization of the temperature field and functional relations for the Nusselt number are proposed in terms of the Dean and Prandtl numbers. (orig.)
2005-11-01
The present study investigates the effect of the shear rate-dependent thermal conductivity of non-Newtonian fluids on the heat transfer enhancement in a pipe flow. The constant heat flux as thermal boundary condition was adopted in the thermally developed region. The present analytical results show the heat transfer enhancement over those of a shear rate-independent thermal conductivity fluid. The heat transfer coefficient ratio (h/h{sub 0}) linearly increase with the non-dimensional average velocity difference which is the product of the shear rate-dependence of the thermal conductivity and wall-shear rate.
1996-09-01
Stress fracture of the clavicle associated with sternocostoclavicular hyperostosis
Energy Technology Data Exchange (ETDEWEB)
We report a case of stress fracture of the clavicle associated with sternocostoclavicular hyperostosis. A 60-year-old man sustained a stress fracture of the right clavicle with no history of trauma. On radiography, hyperostosis of the anterior chest wall and ankylosis of the sternoclavicular joint were evident in addition to the fracture. Fracture healing was uneventful after 2.5 months. Ankylosis of the sternoclavicular joint may have caused increased stress at the midshaft of the clavicle by daily activity or minor trauma. Such a fracture is a rare complication of sternocostoclavicular hyperostosis. (orig.)
2005-07-01
Reactive sticking coefficients for silane and disilane on polycrystalline silicon
Energy Technology Data Exchange (ETDEWEB)
Reactive sticking coefficients (RSCs) were measured for silane and disilane on polycrystalline silicon for a wide range of temperature and flux (pressure) conditions. The data were obtained from deposition-rate measurements using molecular beam scattering and a very low-pressure cold-wall reactor. The RSCs have nonlinear Arrhenius temperature dependencies and decrease with increasing flux at low (710 /sup 0/C) temperatures. Several simple models are proposed to explain these observations. The results are compared with previous studies of the SiH/sub 4//Si(s) reaction and low-pressure chemical vapor deposition-rate measurements.
1988-04-15
Nonlinear dynamics of heat transfer enhancement using eddy promoters
This investigation concerns the nonlinear dynamics of heat transfer from a surface using an upstream eddy promoter. A numerical model is developed for the coupled fluid flow and heat transfer process based on a modified MacCormack scheme. Numerical simulations are carried out to determine the response and heat transfer enhancement due to the promoter. The average heat transfer from a cavity floor is seen to be increased by a factor of approximately five over the unpromoted'' flow. Another interesting feature of the study is the nonlinear viscous flow dynamics from the cylinder-wall interaction which differ significantly from the familiar cylinder-free stream patterns.
1994-02-01
Nonlinear dynamics of heat transfer enhancement using eddy promoters
Energy Technology Data Exchange (ETDEWEB)
This investigation concerns the nonlinear dynamics of heat transfer from a surface using an upstream eddy promoter. A numerical model is developed for the coupled fluid flow and heat transfer process based on a modified MacCormack scheme. Numerical simulations are carried out to determine the response and heat transfer enhancement due to the promoter. The average heat transfer from a cavity floor is seen to be increased by a factor of approximately five over the unpromoted'' flow. Another interesting feature of the study is the nonlinear viscous flow dynamics from the cylinder-wall interaction which differ significantly from the familiar cylinder-free stream patterns.
1994-02-01
International Nuclear Information System (INIS)
In this study, Multi-Walled Carbon Nanotubes (MWCNTs) / Hydroxylapatite (HAp) composites were made to improve mechanical properties by using Spark Plasma Sintering (SPS) method. Slurry 6 mol of CaHPO4#centre dot#2H2O (DCPD), 4 mol calcium hydroxide and MWCNTs were mixed and sintered by using SPS at 5-120 MPa pressure, 1200-1250 deg. C and in vacuum or N2 atmosphere. The fracture toughness of sintered MWCNTs/HAp composites was increased.
2006-05-05
Application of light microscopy to direct coal liquefaction research
Energy Technology Data Exchange (ETDEWEB)
Light microscopy was used to analyze the effects of added catalyst at different conditions (temperature and reaction times) in liquefaction testing of a low pyritic sulfur bituminous coal. Quantitative changes in vitrinite/vitroplast reflectance of coal and liquefaction residues were shown to be useful markers in analyzing and understanding the role of catalyst during the initial stage of coal particle hydrogenation. Lower reflectance values corresponded to increased conversions up to about the 60 min and 375{degrees}C experimental conditions. Microscopical observation of liquefaction residues also revealed the presence of `wall scales` of varying width.
1998-01-01
Heat transfer augmentation through wall-shape-induced flow destabilization
Energy Technology Data Exchange (ETDEWEB)
Experiments on heat transfer augmentation in a rectangular cross-section water channel are reported. The channel geometry is designed to excite normally damped Tollmein-Schlichting modes in order to enhance mixing. In this experiment, a hydrodynamically fully developed flow encounters a test section where one channel boundary is a series of periodic, saw-tooth, transverse grooves. Free shear layers span the groove openings, separating the main channel flow from the circulating vortices contained within each cavity. The periodicity length of the grooves is equal to one-half of the expected wavelength of the most unstable mode. The remaining channel walls are flat, and the channel has an aspect ratio of 10:1. Experiments are performed over the Reynolds number range of 300 to 15,000. Streakline flow visualization shows that the flow is steady at the entrance, but becomes oscillatory downstream of an onset location. This location moves upstream with ...
1990-05-01
Energy Technology Data Exchange (ETDEWEB)
The usefulness of helical CT early phase images optimized by the SmartPrep method for evaluation of wall invasion by colorectal cancer was investigated. Between August 1997 and September 1998, CT was performed to evaluate the primary tumor and local extension in 10 consecutive patients with colorectal cancer confirmed by barium enema- and/or colonoscopy. Early-phase images were acquired by using SmartPrep application software. This method allows the optimal scan delay time to be obtained by continuous monitoring of increases in CT values after injection of contrast medium. Sections of the surgical specimens, close to the same plane as the CT images, and of the same slice thickness, were analyzed histopathologically. All 10 cancers, regardless of size, showed strong enhancement on the early-phase images (81.4-112 HU, mean: 95.1 HU). The strongly enhanced image areas on CT corresponded to the primary cancer areas on histopathological specimens. A ...
2000-02-01
Vertically aligned carbon nanotube electrodes for lithium-ion batteries
British Library Electronic Table of Contents (United Kingdom)
As portable electronics become more advanced and alternative energy demands become more prevalent, the development of advanced energy storage technologies is becoming ever more critical in today's society. In order to develop higher power and energy density batteries, innovative electrode materials that provide increased storage capacity, greater rate capabilities, and good cyclability must be developed. Nanostructured materials are gaining increased attention because of their potential to mitigate current electrode limitations. Here we report on the use of vertically aligned multi-walled carbon nanotubes (VA-MWNTs) as the active electrode material in lithium-ion batteries. At low specific currents, these VA-MWNTs have shown high reversible specific capacities (up to 782mAhg^-^1 at 57mAg^-...
2011-01-01
Market assessment for the fan atomized oil burner
Energy Technology Data Exchange (ETDEWEB)
The market potential for the fan atomized burner (FAB) in water and space heating applications was examined. The major findings of the study are as follows. (1). The FAB`s low-input capability allows development of oil-fired room heaters and wall furnaces, a new market area for oil heat. (2). Among conventional oil-fired products, furnaces will benefit most from the burner`s low input capability due to (1) their quick delivery of heat and (2) their more prevalent use in warmer climates and smaller homes. (3). The greatest potential for increased product sales or oil sales exists in the use of the burner with new products (i.e., room heaters). Sales of boilers and direct-fired water heaters are not likely to increase with the use of the burner. (4). Acceptance of the burner will be dependent on proof of reliability. Proof of better reliability than conventional burners would accelerate acceptance.
1996-07-01
Inspection pig for gas pipeline
Energy Technology Data Exchange (ETDEWEB)
The ultrasonic inspection pig system was described as being under development. This system was said to adopt the unique wheel type ultrasonic sensor which does not need couplant. This pig was designed to detect external corrosion in long-distance pipelines without interruption of the gas service. The wall-thickness measurement performance test and the travel performance test of the inspection pig in the test line confirmed that these performances satisfied the development specifications. However, the effect induced by the inner surface properties of the pipe and the influence of the pipe`s performance over long distances and for a long period of time still needed to be verified in an actual gas pipeline, and while the pipeline was actually in service. Improvements to the prototype model of the inspection pig were expected to include combinations of inspection pigs, with increases in battery and memory capacities to permit them to cope with in ...
1992-12-31
Aluminum Tolerance in Moso Bamboo (Phyllostachys pubescens)
British Library Electronic Table of Contents (United Kingdom)
Moso bamboo (Phyllostachys pubescens) is widely distributed in the acid soil region of Southern China, where great potential of aluminum (Al) toxicity exists. To evaluate the Al tolerance of Moso bamboo, seed germination and root elongation were compared with two rice cultivars, and physical and physiological damages were examined under various levels of Al stress. Results showed that Moso bamboo seed germination was inhibited when Al concentration increased to 500 ?M, and the median lethal concentration was 2,000??M. Comparatively, the rice seed germination was not inhibited even at a concentration of 2,000??M Al. Aluminum accumulated mainly in the cell wall of root apices, and entered into protoplasts as treating time prolonged and/or Al concentration increased, which resulted in apoptos...
2011-01-01
International Nuclear Information System (INIS)
The VE (ventilation) test carried out at the Mont Terri underground laboratory in Switzerland intended to evaluate in situ the behaviour of a consolidated clay formation when subjected to alternate periods of flow of wet and dry air during several months. For that, a 10-m gallery was excavated in the Opalinus Clay formation and carefully instrumented. Before and after a second ventilation phase boreholes were drilled. Samples were taken from the drill cores and were analysed from mineralogical and geochemical points of view. Also, the retention curves of these samples were determined in the laboratory following drying paths performed under free volume conditions at 20 degree centigrade, what is the content of this report. Although there are not large differences in the WRC of samples taken from different boreholes, at different distances from the gallery wall or before or after ventilation, those samples taken near the gallery wall and after ...
2010-11-01
Velocity measurement of wake behind flat plate simulating BWR fuel spacer
International Nuclear Information System (INIS)
Velocity field behind a flat plate, placed near the wall in a narrow channel as a simulant of a BWR fuel spacer, was measured by using a hot wire anemometer. It was found that not only the positions where the dead water region behind flat plate disappeared but also the locations where the velocity relaxation completed were almost independent of the width of the clearance, although the local average velocity and velocity fluctuation immediately downstream the flat plate were affected by the difference in the clearance. The transverse flow diversions in the channel cross section were evaluated from the shape of the average velocity profile. The decrease of local flow rate near the channel wall, which may causes the drift flow behind a flat plate, was encouraged as the drag of clearance increased. Attempts have been made to measure spanwise velocity in the narrow channel. A spanwise velocity that occurred due to flow diversion ...
2004-10-04
International Nuclear Information System (INIS)
When liquids are confined in nano-scopic dimensions, their properties differ from the corresponding bulk liquid, due to their reduced dimensionality and surface effects. Phase transition temperatures and pressures are often shifted from the bulk values and new phases can appear due to the strong interactions of the molecules with the confining walls. We have studied the structural and dynamical properties of aromatic liquids such as benzene, toluene, and ortho-terphenyl confined in nano-porous materials, MCM-41 and SBA-15, synthesized and characterized in our laboratory. A non-trivial dependence of the glass transition temperature, Tg, on the pore size and surface treatment of nano-porous materials is confirmed and interpreted as resulting from a competition between the fluid-wall and fluid-fluid intermolecular interactions. An increase of Tg is observed for small pore sizes and attractive surface while Tg decreases for non ...
2006-01-01
Probabilistic fracture assessment of TAPP 3-4 PHT piping
International Nuclear Information System (INIS)
Methodology based on probabilistic fracture mechanics (PFM) is finding increasing acceptability in demonstrating safety of Nuclear Power Plant (NPP) piping. In PFM, the methods of fracture mechanics and reliability theory are combined for assessing the reliability of components, which contain cracks. In this work, reliability assessment of Tarapur Atomic Power Plant (TAPP) 3-4 Primary Heat Transport (PHT) piping is done using PFM. Monte Carlo simulation with stratified sampling is used as a variance reduction technique. PFM model assumes a pre-existing circumferential surface crack before the start of plant operation. The crack grows in size during the lifetime of the plant due to the fatigue loading. This part-through wall crack having escaped hydro-test and pre-service inspection, may result in either a through wall flaw (leak) or may lead to the rupture of the piping. R6 method is used as failure criteria. Steam ...
2005-12-01
Numerical studies of an impingement-conditioned small direct-injection diesel engine
Energy Technology Data Exchange (ETDEWEB)
Numerical studies are performed to identify an optimal range of geometric parameters in connection with the design of an impingement-conditioned small direct-injection diesel engine. The parametric studies were made in a pressure chamber with a circular protrusion on to which sprays are directed to impinge. Computational runs were made for 24 cases carefully chosen to allow examination of the effects on post-impingement spray characteristics of the following parameters: (a) the nozzle-plate distance and (b) the size and geometry pattern of the protrusion. An optimal range of these parameters has been identified through an analysis of the calculated results in terms of vapour concentration, the Sauter mean diameter of the wall spray and the dispersed wall spray volume. The results obtained also reveals that, by just changing the size of the impingement surface and the impingement distance, local fuel vaporization efficiency can be ...
1999-07-01
Energy Technology Data Exchange (ETDEWEB)
Flow fields, temperature distributions, and particle trajectories in a 2-stage entrained-flow gasifier are calculated using a CFD code, FLUENT. Realizable k- {epsilon} model is used as a turbulent model. Because of swirling flow there appear recirculation regions near the burners. The characteristics of flow fields and temperature distributions in the gasifier are dependent on the swirl number of the system. Mean residence time of the particles in the reductor is inversely proportional to particle size, particle density and swirl number. As the swirl number is increasing, the particles injected from the combustor burners approach the wall near the combustor burners, which prevents the particles from entering the reductor and thus attaching the reductor wall. If the lower combustor burner angle is larger than the higher combustor burner angle for a given swirl number, the particles may move toward the reductor and cause ...
2001-07-01
MAPLE/HANARO type fuel element two-phase flow parameter measurement by real-time neutron radiography
Energy Technology Data Exchange (ETDEWEB)
The objective of this work is the measurement of two-phase flow parameters to support development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR). A single element finned Fuel Element Simulator was used with R134a Freon flow. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distributions were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly limits any significant vibration and the local void distribution ...
2002-07-01
MAPLE/HANARO type fuel element two-phase flow parameter measurement by real-time neutron radiography
International Nuclear Information System (INIS)
The objective of this work is the measurement of two-phase flow parameters to support development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR). A single element finned Fuel Element Simulator was used with R134a Freon flow. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distributions were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly limits any significant vibration and the local void distribution ...
2002-08-11
Functionalized multi-walled carbon nanotubes as affinity ligands
Energy Technology Data Exchange (ETDEWEB)
Functionalization of carbon nanotubes is very challenging for their applications. The paper here describes a new method to functionalize multi-walled carbon nanotubes (MWCNTs) as specific affinity adsorbents. MWCNTs were acid purified and pretreated with (3-aminopropyl)-triethoxysilane (APTES) in order to introduce abundant amino groups on the surface of MWCNTs. After the conversion of amino groups to carboxyl groups by succinic acid anhydride, MWCNTs were attached to protein A or aminodextran using 1-ethyl-3,3' (dimethylamion)-propylcarbodiimide as a biofunctional crosslinker. The incorporation of aminodextran as a spacer arm noticeably increased the binding capacity of the APTES-modified MWCNTs for protein A. The application of affinity MWCNTs for purification of immunoglobulin G was then evaluated. The affinity of MWCNTs with AMD spacer exhibited a high adsorption capacity of {approx}361 {mu}g IgG/mg MWCNT (wet basis). About 75% of ...
2007-03-21
Finned fuel element two-phase flow parameter measurements using real-time neutron radiography
International Nuclear Information System (INIS)
The measurement of two-phase flow parameters and development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR) is discussed in this paper. A single element finned Fuel Element Simulator (FES) was used with R134a Freon as the working fluid. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distribution were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly limits any significant vibration and the local void ...
2007-04-22
Finned fuel element two-phase flow parameter measurements using real-time neutron radiography
International Nuclear Information System (INIS)
The measurement of two-phase flow parameters for development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR) is discussed in this paper. A single element finned Fuel Element Simulator (FES) was used with Freon 134a as the working fluid. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer present. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distribution were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly limits any significant vibration and the local ...
2008-02-01
Causes of poor sealant performance in soil-gas-resistant foundations
International Nuclear Information System (INIS)
Sealants for radon-resistant foundation construction must seal the gap between concrete sections. Modern sealants have such low permeability that seal performance depends only on the permeability of the material that contacts the sealant. The surface permeability of concrete walls and floors was measured by a specially designed permeameter, which measures the airflow induced by a pressure difference across a temporary test seal applied to the surface. The permeability of bulk concrete is about 10"-"1"5 m"2. Areas free of surface defects had surface permeability ranging from 10"-"1"4 to 10"-"1"6 m"2. However, surface defects are common on concrete wall surfaces, which increase the permeability to >10"-"1"2 m"2, too high for standard seal designs to be adequate as the only method of soil gas and radon exclusion. Radon-resistant seals require either extended contact widths or mechanical removal of the surface layer and ...
A new method of heat transfer augmentation by means of foreign gas jet impingement in liquid bath
International Nuclear Information System (INIS)
The authors discuss a two-phase two-component experimental system developed to study enhancement of heat transfer from a vertical chip size heater to surrounding liquid (Freon 113 or Ethanol) due to air jet impingement. Heat transfer coefficient was measured as function of jet velocity, heat flux and the distance between exit of jet tube and heated surface. The injector was placed very close to the hot surface. It was found that the heat transfer was notably enhanced with foreign gas impingement, especially in the cases of small temperature differences between wall and coolant. In fact for higher jet velocities the heat transfer coefficients tended to infinite while the temperature differences between wall and coolant were zero. The heat transfer coefficients decreased with the increasing of heat flux. High-speed camera was used to study the behaviour of the gas bubbles which play very important role in the heat transfer ...
1985-10-01
Microstructure and magnetic properties of nanocrystalline Fe75Si20M5 (M = Al, B, Cr) powders
International Nuclear Information System (INIS)
Nanocrystalline Fe75Si20M5 (M = Al, B and Cr) powders were synthesized by mechanical alloying in a planetary ball mill from high purity elemental powders. Evolution of non-equilibrium solid solutions of ?-Fe[Si,(Al, B, Cr)] with a nanocrystalline structure was accompanied by the introduction of a large number of dislocation defects in the course of the milling process. Fe sites get substituted by Si and M (M = Al, B, Cr) atoms during the milling process. The structural change and the resulting disorder are reflected in the changes in the lattice parameter and average magnetic moment of the powders milled for various time periods. The effective magnetic anisotropy increases linearly with the milling time. An increase in coercivity with increasing milling time was observed which could be attributed to the introduction of dislocations and the reduction in the powder particle size during milling. The presence of dislocations ...
2008-08-21
Influence of moisture on flow property indicators of poor quality anthracite
Energy Technology Data Exchange (ETDEWEB)
Describes investigations into flow density, angle of repose, coefficients of friction and adhesion using poor quality anthracite culm (from the 50-letie Ukrainy mine) and anthracite slurry with a high ash content (from the Tsentral'naya and Partizanskaya mines) on samples of varying moisture content (2-22%). The results show that flow properties are impaired when anthracite has a moisture content of 8.5 to 9.5%; when these anthracites are used in electric power plants they should be stored in bunkers with walls with a slope of greater than 70 degrees (or dried) to prevent sticking. Results of investigations into internal and external friction, adhesion and cohesion varied for the different samples, but the highest coefficient of internal friction was found with concrete where it increases continuously with moisture content. With rubber, PVC, St. 3 steel and stainless steel, the friction coefficient increases with ...
1988-03-01
Mechanical Engineering and Design of the LHC Phase II Collimators
Phase II collimators will complement the existing system to improve the expected high RF impedance and limited efficiency of Phase I jaws. An international collaborative effort has been launched to identify novel advanced materials responding to the very challenging requirements of the new collimators. Complex numerical calculations simulating extreme conditions and experimental tests are in progress. In parallel, an innovative modular design concept of the jaw assembly is being developed to allow fitting in alternative materials, minimizing the thermally induced deformations, withstanding accidents and accepting high radiation doses. Phase II jaw assembly is made up of a molybdenum back-stiffener ensuring high geometrical stability and a modular jaw split in threes sectors. Each sector is equipped with a high-efficiency independent cooling circuit. Beam position monitors (BPM) are embedded in the jaws to fasten setup time and improve beam monitoring. An adjustment ...
2010-01-01
High damping Fe-Mn martensitic alloys for engineering applications
International Nuclear Information System (INIS)
Conventional methods for reducing vibration in engineering designs (i.e. by stiffening or detuning) may be undesirable or inadequate in conditions where size or weight must be minimized or where complex vibration spectra exist. Alloys which combine high damping capacity with good mechanical properties can provide attractive technical and economic solutions to problems involving seismic, shock and vibration isolation. To meet these trends, we have developed a new high damping Fe-17%Mn alloy. Also, the alloy has advantages of good mechanical properties and is more economical than any other known damping alloys (a quarter the cost of non-ferrous damping alloy). Thus, the high damping Fe-17%Mn alloy can be widely applied to household appliances, automobiles, industrial facilities and power plant components with its excellent damping capacity (SDC, 30%) and mechanical property (T.S. 700 MPa). It is the purpose of this paper to introduce the characterization of the high ...
2000-06-01
BARBOX: An alternative system concept for floating production, storage, and offloading
Energy Technology Data Exchange (ETDEWEB)
This paper describes the Brown and Root`s BARBOX, an alternative, purpose-built, deep-draft monohull system for floating production, storage, and offloading (FPSO). This alternative system concept has been designed for worldwide applications including the North Sea and the Gulf of Mexico environments. The stiffened flat plate construction of the BARBOX gives it a low capital investment cost relative to minimum water plane hull types (e.g., semi-submersible, SPAR, TLP) and ship-shaped FPSO. Dynamic motion comparison between the BARBOX and the ship-shaped FPSO indicates that the BARBOX`s motion characteristics are similar or better than those of comparable ship-shaped FPSO configurations. This paper also considers construction of the BARBOX hull in the Gulf of Mexico region. A recent study indicated that the Gulf coast fabrication yards were technically capable to fabricate the BARBOX hull and they could be cost competitive against worldwide shipyards.
1997-07-01
A laboratory study on the thermomechanical behaviour of clayey soils
Energy Technology Data Exchange (ETDEWEB)
The thermomechanical behaviour of clayey soils was examined in a laboratory study because of their importance in some engineering applications such as hydrocarbon extraction from oil-bearing sands and radioactive waste disposal. The slightest temperature variations have been known to have an impact on the mechanical behaviour of clayey soils. In this study, tests were conducted on reconstituted and natural clayey soils using triaxial cells modified to control temperatures. Changes of temperature and stress state were not applied simultaneously. Instead, the tests were divided into two separate sections aimed at studying the thermal and mechanical behaviour of clays. The thermal behaviour tests examined the deformations induced by drainage temperature changes as well as pore-pressure generation and consolidation phenomena. The mechanical behaviour tests, focused on the influence of temperature and temperature history on compressibility, deformability and shear strength. The range of ...
2000-08-04
Subcellular Localization of Expansin mRNA in Xylem Cells12
UK PubMed Central (United Kingdom)
Terminal differentiation of many vascular cells involves cell wall changes. Cells first elongate their primary wall, then lay down a lignified secondary wall, which is often followed by digestion of...Full Text Available
2000-06-01
Gravitational Waves from Collapsing Domain Walls
We study the production of gravitational waves from cosmic domain walls created during phase transition in the early universe. We investigate the process of formation and evolution of domain walls by running three dimensional lattice simulations. If we introduce an approximate discrete symmetry, walls become metastable and finally disappear. We calculate the spectrum of gravitational waves produced by collapsing metastable domain walls. Extrapolating the numerical results, we find the signal of gravitational waves produced by domain walls whose energy scale is around 10^10-10^12GeV will be observable in the next generation gravitational wave interferometers.
2010-01-01
The Structure of Plant Cell Walls
UK PubMed Central (United Kingdom)
The molecular structure, chemical properties, and biological function of the xyloglucan polysaccharide isolated from cell walls of suspension-cultured sycamore (Acer pseudoplatanus)...Full Text Available
1973-01-01
Constraints on target chamber first wall and target designs that will enable NIF debris shields to survive
1999-01-01
Energy Technology Data Exchange (ETDEWEB)
This paper extends the analytical procedure described in another paper in these proceedings to analyze a variety of compact and light-weight OSC-designed radioisotope-heated generators. Those generators employed General Purpose Heat Source (GPHS) modules and a converter containing sixteen AMTEC cells of OSC`s revised five-tube design with enhanced cell wall reflectivity described in a companion paper in these proceedings. OSC found that the performance of the generator is primarily a function of the thermal insulation between the outside of the generator`s 16 cells and the inside of its wall. After examining a variety of insulation options, it was found that the generator`s performance is optimized by employing a hybrid insulation system, in which the space between the cells is filled with fibrous Min-K insulation, and the generator walls are lined with tapered (i.e., graded-length) multifoil insulation. The OSC design ...
1997-12-31
Energy Technology Data Exchange (ETDEWEB)
The ability of residual biomass from the thermotolerant ethanol-producing yeast strain Kluyveromyces marxianus IMB3 to function as a biosorbent for uranium has been examined. It was found that the biomass had an observed maximum biosorption capacity of 120 mg U/g dry weight of biomass. The calculated value for the biosorption maximum, obtained by fitting the data to the Langmuir model was found to be 130 mg U/g dry weight biomass. Maximum biosorption capacities were examined at a number of temperatures and both the observed and calculated values obtained for those capacities increased with increasing temperature. Decreasing the pH of the biosorbate solution resulted in a decrease in uptake capacity. When biosorption reactions were carried out using sea-water as the diluent it was found that the maximum biosorption capacity of the biomass increased significantly. Using transmission electron microscopy, uranium crystals were ...
1997-06-01
Materials needs for compact fusion reactors
Energy Technology Data Exchange (ETDEWEB)
The economic prospects for magnetic fusion energy can be dramatically improved if for the same total power output the fusion neutron first-wall (FW) loading and the system power density can be increased by factors of 3 to 5 and 10 to 30, respectively. A number of compact fusion reactor embodiments have been proposed, all of which would operate with increased FW loadings, would use thin (0.5 to 0.6 m) blankets, and would confine quasi-steady-state plasma with resistive, water-cooled copper or aluminum coils. Increased system power density (5 to 15 MWt/m/sup 3/ versus 0.3 to 0.5 MW/m/sup 3/), considerably reduced physical size of the fusion power core (FPC), and appreciably reduced economic leverage exerted by the FPC and associated physics result. The unique materials requirements anticipated for these compact reactors are outlined against the well documented backdrop provided by similar needs for the ...
1983-01-01
Heat transfer augmentation in 3D internally finned and microfinned helical tube
Energy Technology Data Exchange (ETDEWEB)
Experiments are performed to investigate the single-phase flow and flow-boiling heat transfer augmentation in 3D internally finned and micro-finned helical tubes. The tests for single-phase flow heat transfer augmentation are carried out in helical tubes with a curvature of 0.0663 and a length of 1.15 m, and the examined range of the Reynolds number varies from 1000 to 8500. Within the applied range of Reynolds number, compared with the smooth helical tube, the average heat transfer augmentation ratio for the two finned tubes is 71% and 103%, but associated with a flow resistance increase of 90% and 140%, respectively. A higher fin height gives a higher heat transfer rate and a larger friction flow resistance. The tests for flow-boiling heat transfer are carried out in 3D internally micro-finned helical tube with a curvature of 0.0605 and a length of 0.668 m. Compared with that in the smooth helical tube, the boiling heat transfer coefficient in the 3D internally ...
2005-05-01
Energy Technology Data Exchange (ETDEWEB)
Causes of variation of hydrocarbon (HC) concentration in cylinder to cylinder at idling condition in a direct injection diesel engine were studied. The ratio of l/d=6 gives larger HC variation in cylinder to cylinder than the l/d=2, where l means the nozzle hole length and d means the nozzle hole diameter. This is because the condition of l/d=6 can result in the large spray penetration and increase the fuel on the combustion chamber. The spray structure changes between nozzles and also changes between nozzle holes. This is not caused by the shape of nozzle hole but is affected by the pressure change near the inlet of nozzle hole when the needle valve is lifted. The change of spray structure can change the injection volume between nozzle holes. The injection volume is less for a nozzle hole where the curved angle becomes sharp to the nozzle central angle, and is more at the opposite side. When the injection volume of the nozzle hole near the chamber ...
1992-07-01
Smart pigs root out pipeline problems
Energy Technology Data Exchange (ETDEWEB)
In the world of pipeline maintenance, there are pigs and there are intelligent pigs. Intelligent pigs, when launched into a pipeline, carry instrumentation onboard which enables them to gather and record information about problems such as denting, corrosion, and cracking. More basic pigs, on the other hand, look after the routine internal maintenance chores such as cleaning and swabbing, or else perform operational duties such as batching different types of product along the line. The harsh environment in which pigs often operate is described. Aside from the mechanical shocks they undergo when passing welds, bends, and other fittings, they may have to contend with hostile conditions such as hydrogen sulfide environments. High pressure is another factor to consider. In crude oil lines, significant paraffin deposits also can cause problems if they affect the sensors ability to maintain good contact with the pipe wall. In spite of these considerations, ...
1983-12-01
Pit lakes: their characteristics and the potential for their remediation
Energy Technology Data Exchange (ETDEWEB)
Pit lakes form when open-pit mining operations are discontinued and dewatering ceases. The increase in open-pit metal mining since the 1970s will lead to the formation of numerous pit lakes over the next 50 years. Many of these lakes will develop acid sulfate conditions with high levels of dissolved metals. Approaches to remediation of these conditions that have been recommended include the addition of lime or other alkaline materials and the stimulation of sulfate-reducing bacteria. However, prevention rather than remediation is probably the preferable approach. Measures to prevent oxidation of mining waste and wall rocks, including measures to fill pits quickly with water, to inhibit the activity of acidophilic sulfur-oxidizing bacteria, and to promote anoxic conditions at the lake bottoms may minimize the formation of acids and dissolved metals. (orig.)
2000-10-01
Energy Technology Data Exchange (ETDEWEB)
Depicts procedures employed to improve work safety at a mine of the Antratsit association in the Ukrainian SSR, where 1K-101 and 2K-52 cutter loaders are used to extract coal at a depth of 750 m. Some 15-20% of accidents is caused by carelessness or clumsiness. To increase awareness among miners, illuminated signs with slogans relating to work safety have been installed at 15 m intervals in roadways leading to workplaces. A satirical wall newspaper lampoons those who infringe safety regulations. Mining teams with good safety records pass on their experience to others. Public inspectors and public inspections (competitions) also play an important part in ensuring that conditions remain up to standard.
1986-04-01
Creep-characteristics of a tropical wood-polymer composite
Energy Technology Data Exchange (ETDEWEB)
Wood polymer composite (WPC) specimens were produced by impregnating a tropical wood with methyl methacrylate and subsequently polymerised by ..gamma..-irradiation. Beam specimens of varying weight percentages of polymer were then subjected to a three point bend creep test under a constant load condition, for 250, 300 and 350 N. A Norton-Bailey (power law) mathematical model was used to describe the creep behavior, with the creep components determined by a nonlinear regression analysis. Significant creep improvements were obtained from the composite specimens as compared to the untreated wood specimens. Results indicated that maximum creep resistance is obtained when the amount of polymer loading exceeded 30%. An interfacial interaction between the polymer and the wood cell wall was used to account for the behavior of the increase in the creep resistance.
1987-01-01
Energy Technology Data Exchange (ETDEWEB)
The catalytically stabilised thermal combustion (CST) of lean hydrogen-air mixtures was investigated numerically in a turbulent channel flow configuration using a two-dimensional elliptic model with detailed heterogeneous and homogeneous chemical reactions. Comparison between turbulent and laminar cases having the same incoming mean properties shows that turbulence inhibits homogeneous ignition due to increased heat transport away from the near-wall layer. The peak root-mean-square temperature and species fluctuations are always located outside the extent of the homogeneous reaction zone indicating that thermochemical fluctuations have no significant influence on gaseous combustion. (author) 4 figs., 6 refs.
1999-08-01
A cone concentrator for high-temperature solar cavity-receivers
Energy Technology Data Exchange (ETDEWEB)
A cone concentrator combined with a solar cavity receiver is presented and its performance compared to a single cavity receiver. For both cases the available heat sink within the receiver is calculated. The cone concentrator suffers from a high amount of rejected rays if the exit aperture is made too small. A larger exit aperture on the other hand increases the thermal losses of the cavity. The optimum cone geometry therefore has to be found taking also into account a model of the cavity. Different operating temperatures and different values of absorption coefficients of the cavity walls are considered. A cone concentrator was built and tested at the solar furnace in Cologne. It transmits 97 percent of the rays entering the entrance aperture, which is in exact agreement with the theoretical predictions. (author)
1999-01-01
Energy Technology Data Exchange (ETDEWEB)
In this thesis, increased hemicellulose retention during kraft pulping has been studied. The work has been divided into three parts: i) Development of an accessible and reliable method for determination of carbohydrate composition of kraft pulps ii) Investigation of the composition and molecular mass distributions of the carbohydrates in kraft pulps with increased hemicellulose content iii) Investigation of the effect of increased hemicellulose content on the sheet properties of kraft pulps with increased hemicellulose content. A method for carbohydrate determination was developed. In this method, enzymes are used to hydrolyse the pulp into monosaccharides. A relatively mild acid hydrolysis is performed prior to detection on an HPLC with an RI-detector. The pulp is not derivatized and no pre-treatment (mechanical or chemical) is needed to determine the carbohydrate composition using the method developed ...
2008-07-01
Transfer of lead through the rats intestinal wall
International Nuclear Information System (INIS)
... females in vitro intestines lead 203 mucous membranes radionuclide kinetics
In-situ maintenance of low-Z limiters in reactors
Energy Technology Data Exchange (ETDEWEB)
In a reactor environment, the surface of a limiter or wall is primarily determined by the mechanism of erosion and deposition of surface material. It should be possible to use pellet injection to reduce net erosion to zero everywhere if low-Z materials are used for the surface. Erosion rates can, in general, be minimized by large area limiters and high plasma temperatures, which transmit power to the walls with less sputtering. Under ideal steady state conditions the wall surface is dominated by metallurgical effects in the wall.
1980-01-01
... presentation will be archived on the OR-Live website. 00:46:02 ANNOUNCER: This has been a ...
Energy Technology Data Exchange (ETDEWEB)
A computed tomography (CT) cut-off for differentiating neoplastic lesions (polyps/carcinoma) from normal colon in contrast-enhanced CT colonography (CTC) relating to the contrast phase and lesion size is determined. CT values of 64 colonic lesions (27 polyps <10 mm, 13 polyps {>=}10 mm, 24 carcinomas) were determined by region-of-interest (ROI) measurements in 38 patients who underwent contrast-enhanced CTC. In addition, the height (H) of the colonic lesions was measured in CT. CT values were also measured in the aorta (A), superior mesenteric vein (V) and colonic wall. The contrast phase was defined by xA + (1 - x)V using x as a weighting factor for describing the different contrast phases ranging from the pure arterial phase (x=1) over the intermediate phases (x=0.9-0.1) to the pure venous phase (x=0). The CT values of the lesions were correlated with their height (H), the different phases (xA + (1 - x)V) and the ratio [xA + (1 - x)V]/H. The CT ...
2004-12-01
Initiation of ecton processes by interaction of a plasma with a microprotrusion on a metal surface
International Nuclear Information System (INIS)
Evolution of rapid (?10 ns) Ohmic overheating of a microprotrusion on a surface in contact with a plasma by emission current is studied taking into account the energy carried by plasma ions and electrons, as well as Ohmic heating, emissive source of energy release (Nottingham effect), and heat removal due to heat conduction. Plasma parameters were considered in the range of n = 1014-1020 cm-3 and Te = 0.1 eV-10 keV. The threshold value of energy transferred to the surface from the plasma is found to be 200 MW/cm2; above this value, heating becomes explosive (namely, an increase in the temperature growth rate (?2T/?t2 > 0) and in passing current (?J/?t > 0) is observed in the final stage at T ? 104 K and j ? 108 A/cm2). In spite of the fact that Ohmic heating does not play any significant role for plasmas with a density lower than 10 18 cm-3 because the current is limited by the space charge of electrons, rapid overheating of top of microprotrusion is observed ...
2008-12-01
Heat transfer augmentation by gas-particle two-phase flow
International Nuclear Information System (INIS)
The helium-cooled HTGR (High Temperature Gas-cooled Reactor) will take an important position in the global energy strategy. It is expected to supply not only electricity but also high quality thermal energy for various industries and local utilities without exhausting any green house effect gas or acid rain gas. The key R and D issue of the HTGR is economical competitiveness, particularly against light water reactors. Due to the poor heat transfer of the single phase helium, the HTGR's volumetric power density is restricted to tenth of corresponding PWR's value so that increasing the power density by improving heat transfer is strongly desired. The standstill can be broken through by adopting gas-solid suspension medium. Its heat transfer performance is quite excellent. Its heat capacity can be increased drastically without excessive pressurization. Although the thermal radiation is a dominant heat transfer mode in high temperature region, the ...
1995-06-01
Involvement of the chest and abdominal wall as a rare manifestation in Hodgkin's disease
Energy Technology Data Exchange (ETDEWEB)
Radiological findings of chest and abdominal wall involvement in Hodgkin's disease are reported. This manifestation was diagnosed in one patient in the primary staging and in two patients during the course of the disease. Typical radiological findings are soft tissue masses in the chest and abdominal wall, in two cases with continous tumor growth of enlarged mediastinal lymphnodes into the anterior chest wall. The axial computed tomography is the best method to evaluate the extent of chest and abdominal wall involvement in Hodgkin's disease.
1983-03-01
Energy Technology Data Exchange (ETDEWEB)
This paper introduces marketability and parts application of PBT in the automotive field. Based on the pursuits in automobiles of weight reduction as measures to improve engine performance, drive performance, and fuel consumption, as well as trends of higher class car orientation, market expansion is expected on engineering resins including PBT. Adoption of PBT/polycarbonate (PC)-based alloy resins is on increase for use in external car parts because of the chemical resistance in PBT, low-temperature shock resistance and appearance of PC. Substitution from Nylon resin in connector application is progressing rapidly because of problems in dimensional stability and compound noise. Air bag sensor parts need to be free of maloperation due to contamination and corrosion in metal contacts caused from gases generated from formed parts, hence development of resins of low gas generation grade is wanted. Valves for exhaust control require high-temperature rigidity, ...
1992-06-18
Scientific Electronic Library Online (English)
Abstract in english The main objective of the research presented here is to relate anatomical features of wood species that affect the interactions between polymeric phases and performance of wood plastic composites (WPC). These interactions are related to the probable interlocking volume and surface area for stress transfer in a WPC. Composites were produced from different wood species and analyzed using SEM (scanning electron microscopy). Results showed that wood species with high interfac (more) ial areas may increase mechanical interlocking, reflected in the viscous constant of the Maxwell model. A complicating factor is that the relation of cell wall thickness-lumen diameter and the interconnectivity between wood cells in a wood, affect the potential for cell collapse. When wood cells collapse, the penetration of the thermoplastic into the wood structure is almost always ceased. The collapse of wood cells during extrusion-injection molding ...
2009-01-01
Heat transfer augmentation in a rectangular channel with a vee-shaped vortex generator
International Nuclear Information System (INIS)
The unsteady flow and heat transfer are simulated using LES and DNS for a channel with two angled ribs as a vee-shaped vortex generator to augment heat transfer. The vortex generators are attached on the bottom wall of the channel and their angles in respect to the main flow are between 10"o and 30"o. The Prandtl number is 0.71 and the Reynolds numbers based on the inflow velocity and the height of channel are from 200 to 2000. Based on the results of this work, the variations of the Nusselt number, pressure coefficient, bulk temperature, friction factor and Colburn factor with the Reynolds numbers and the incidence angles are provided. The relation between the key parameters of the velocity (friction factor f) and thermal (Colburn factor J) boundary layers is calculated for all cases and their values are compared with the predicted values by the Chilton-Colburn analogy. A comparison between the DNS and LES results is performed and it is found that relatively ...
2007-04-01
Energy Technology Data Exchange (ETDEWEB)
Corrosion control on gas pipelines plays an important role on the assessment of pipeline integrity and reliability. In many countries a great extension of buried pipelines is used on transport and distribution systems. This extension will be certainly increased in a near future due to the increasing consumption of natural gas. Inadequate corrosion control can drive to pipeline failures, bringing up the possibility of accidents in populated or environmental protected areas, bringing together severe economical, legal and environmental consequences. Corrosion is frequently considered as a natural and inevitable phenomenon. Based upon this assumption, some recommendations are included on design standards of gas pipelines in order to compensate its detrimental effect. The aim of this work is to present a review of the correlation between external corrosion process and the guidelines established during the project phase of gas pipelines. It is ...
2004-07-01
International Nuclear Information System (INIS)
Statements about the dynamic processes of uptake, transport, and deposition of Ca and Mg in norway spruce and Scots pine are made in this paper. Concerning the storage of these elements it is shown that there are great differences in their functional importance in cell metabolism. There is evidence that the role of Mg in enzyme and protein metabolism is of far greater significance for the understanding of Mg-deficiency symptoms than its function as the central atom of the chlorophyll complexes. In regard to the transport and especially to the incorporation of Ca into the needles differences between species were evident, expressing the special status of pine among the gymnosperms. With increasing needle age an accumulation of Ca-oxalate crystals, which are physiologically inert, could be proved for the studied conifers. This was interpreted as a 'detoxication' from surplus Ca to hold constant the level of the physiologically active fraction. Accordingly, the low ...
Endothelial dysfunction and increased platelet aggregation may be involved in the pathogenesis of normal tissue radiation toxicity. This study assessed clopidogrel, an inhibitor of ADP-induced platelet aggregation, as a modulator of intestinal radiation injury (radiation enteropathy). Rat small intestine was exposed to 21 Gy X-radiation. Clopidogrel (20 mg/kg/day) or vehicle was administered from 2 days before to 10 days after irradiation. Structural radiation injury, neutrophil infiltration, smooth muscle cell proliferation, collagen content, and TGF-beta1 expression were assessed 2 weeks (early phase) and 26 weeks (delayed phase) after irradiation, using quantitative histology and immunohistochemistry, morphometry, and real-time fluorogenic probe RT-PCR. Irradiated intestine exhibited significant histopathologic injury, reduced mucosal surface area, vascular sclerosis, intestinal wall fibrosis, increased collagen content, ...
2002-01-01
Crack propagation and arrest of structural steels and pipelines
Energy Technology Data Exchange (ETDEWEB)
Crack arrest of fast running cracks is an important issue for the safety of steel structures. Crack arrest design can prevent fatal damage of large structures by restricting the influence of the incidents. Therefore crack arrest design is important especially for very large structure, where accidents may cause huge economical and social losses. Propagating shear fracture, long running ductile crack propagation in pipelines and brittle crack propagation in heavy thick shipbuilding steels have been investigated. For the propagating shear fracture issue, a new HLP simulation model, applicable to various backfill conditions, including underwater backfill, was developed. The proposed backfill model can be applied to the prediction of the crack arrest of propagating shear fracture under various backfill conditions. The new HLP simulation was successful in estimating full-scale burst tests with various backfill depths. The new HLP simulation for underwater pipelines indicated that propagating ...
2008-07-01
Energy Technology Data Exchange (ETDEWEB)
Strong perpendicular anisotropy systems consisting of Co/Pt multilayer stacks that are antiferromagnetically coupled via thin Ru or NiO layers have been used as model systems to study the competition between local interlayer exchange and long-range dipolar interactions [1,2]. Magnetic Force Microscopy (MFM) studies of such systems reveal complex magnetic configurations with a mix of antiferromagnetic (AF) and ferromagnetic (FM) phases. However, MFM allows detecting surface stray fields only and can interact strongly with the magnetic structure of the sample, thus altering the original domain configuration of interest [3,4]. In the current study they combine magnetometry and state-of-the-art soft X-ray transmission microscopy (MXTM) to investigate the external field driven FM phase evolution originating from the domain boundaries in such antiferromagnetically coupled perpendicular anisotropy films. MXTM allows directly imaging the perpendicular component of the magnetization in an ...
2008-05-01
Effect of water chemistry improvement on flow accelerated corrosion in light-water nuclear reactor
International Nuclear Information System (INIS)
Flow Accelerated Corrosion (FAC) of Carbon Steel (CS) piping has been one of main issues in Light-Water Nuclear Reactor (LWRs). Wall thinning of CS piping due to FAC increases potential risk of pipe rupture and cost for inspection and replacement of damaged pipes. In particular, corrosion products generated by FAC of CS piping brought steam generator (SG) tube corrosion and degradation of thermal performance, when it intruded and accumulated in secondary side of PWR. To preserve SG integrity by suppressing the corrosion of CS, High-AVT chemistry (Feedwater pH9.8#+-#0.2) has been adopted to Tsuruga-2 (1160 MWe PWR, commercial operation in 1987) in July 2005 instead of conventional Low-AVT chemistry (Feedwater pH 9.3). By the High-AVT adoption, the accumulation rate of iron in SG was reduced to one-quarter of that under conventional Low-AVT. As a result, a tendency to degradation of the SG thermal efficiency was improved. On the other hand, it ...
2009-10-01
Revisited the mathematical derivation wall thickness measurement of pipe for radiography
Energy Technology Data Exchange (ETDEWEB)
Wall thickness measurement of pipe is very important of the structural integrity of the industrial plant. However, the radiography method has an advantage because the ability of penetrating the insulated pipe. This will have economic benefit for industry. Moreover, the era of digital radiography has more advantages because the speed of radiographic work, less exposure time and no chemical used for film development. Either the conventional radiography or digital radiology, the wall thickness measurement is using the tangential radiography technique (TRT). In case, of a large diameter, pipe (more than inches) the determination maximum penetration wall thickness must be taken into the consideration. This paper is revisited the mathematical derivation of the determination of wall thickness measurement based on tangential radiography technique (TRT). The mathematical approach used in this derivation is the ...
2007-07-01
Applicability of structural wall test results to seismic design of nuclear facilities
International Nuclear Information System (INIS)
A review of tests on earthquake-resistant reinforced concrete structural walls is presented. Laboratory tests of isolated walls and construction joints are discussed. Where appropriate, design recommendations are given. The review indicates only few experimental data are available for short walls which are directly applicable to nuclear power plant design. In particular, tests of short rectangular walls subjected to load reversals are needed. Tests are also needed to determine the damping and frequency characteristics of cracked short walls. Analytical and experimental results should be correlated so that the hysteretic response observed in tests can be realistically related to the analytical response 'demand' of nuclear power plant structures. (Auth.).
A task-based usage strategy for control centre wall displays
Energy Technology Data Exchange (ETDEWEB)
This paper summarizes the findings from an exploratory definition of a usage strategy for multiple control centre wall displays in CANDU nuclear power plants. Wall displays are defined as large sized, vertically oriented display surfaces that may be positioned in various locations about a control room to support user information needs. The paper begins by discussing the need for a usage strategy for all control room information resources, and then reviews the history in wall display implementation and usage in nuclear power plant control rooms. The balance of the paper discusses the approach used in characterization and review of control room task information needs and definition of a wall display usage strategy. The paper concludes by outlining some of the possible impacts on future control room design and operations that the introduction of wall displays may imply. (author)
2005-07-01
International Nuclear Information System (INIS)
A highly sensitive and stable tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)_3 "2"+) electrogenerated chemiluminescence (ECL) sensor was developed based on carbon nanotube (CNT) dispersed in mesoporous composite films of sol-gel titania and perfluorosulfonated ionomer (Nafion). Single-wall (SWCNT) and multi-wall carbon nanotubes (MWCNT) can be easily dispersed in the titania-Nafion composite solution. The hydrophobic CNT in the titania-Nafion composite films coated on a glassy carbon electrode certainly increased the amount of Ru(bpy)_3 "2"+ immobilized in the ECL sensor by adsorption of Ru(bpy)_3 "2"+ onto CNT surface, the electrocatalytic activity towards the oxidation of hydrophobic analytes, and the electronic conductivity of the composite films. Therefore, the present ECL sensor based on the CNT-titania-Nafion showed improved ECL sensitivity for tripropylamine (TPA) compared to the ECL sensors based on both titania-Nafion ...
2006-04-13
Energy Technology Data Exchange (ETDEWEB)
A highly sensitive and stable tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy){sub 3} {sup 2+}) electrogenerated chemiluminescence (ECL) sensor was developed based on carbon nanotube (CNT) dispersed in mesoporous composite films of sol-gel titania and perfluorosulfonated ionomer (Nafion). Single-wall (SWCNT) and multi-wall carbon nanotubes (MWCNT) can be easily dispersed in the titania-Nafion composite solution. The hydrophobic CNT in the titania-Nafion composite films coated on a glassy carbon electrode certainly increased the amount of Ru(bpy){sub 3} {sup 2+} immobilized in the ECL sensor by adsorption of Ru(bpy){sub 3} {sup 2+} onto CNT surface, the electrocatalytic activity towards the oxidation of hydrophobic analytes, and the electronic conductivity of the composite films. Therefore, the present ECL sensor based on the CNT-titania-Nafion showed improved ECL sensitivity for tripropylamine (TPA) compared to the ECL ...
2006-04-13
Energy Technology Data Exchange (ETDEWEB)
When liquids are confined in nano-scopic dimensions, their properties differ from the corresponding bulk liquid, due to their reduced dimensionality and surface effects. Phase transition temperatures and pressures are often shifted from the bulk values and new phases can appear due to the strong interactions of the molecules with the confining walls. We have studied the structural and dynamical properties of aromatic liquids such as benzene, toluene, and ortho-terphenyl confined in nano-porous materials, MCM-41 and SBA-15, synthesized and characterized in our laboratory. A non-trivial dependence of the glass transition temperature, T{sub g}, on the pore size and surface treatment of nano-porous materials is confirmed and interpreted as resulting from a competition between the fluid-wall and fluid-fluid intermolecular interactions. An increase of T{sub g} is observed for small pore sizes and attractive surface while T{sub g} ...
2006-11-15
Numerical study of natural convection in fully open tilted cavities
Energy Technology Data Exchange (ETDEWEB)
A numerical simulation of two-dimensional laminar natural convection in a fully open tilted square cavity with an isothermally heated back wall is conducted. The remaining two walls of the cavity are adiabatic. Steady-state solutions are presented for Grashof numbers between 10{sup 2} and 10{sup 5} and for tilt angles ranging from {minus}60{degree} to 90{degree} (where 90{degree} represents a cavity with the opening facing down). The fluid properties are assumed to be constant except for the density variation with temperature that gives rise to the buoyancy forces, which is treated by the Boussinesq approximation. The fluid concerned is air with Prandtl number fixed at 0.71. The governing equations are expressed in a normalized primitive variables formulation. Numerical predictions of the velocity and temperature fields are obtained using the finite-volume-based power law (SIMPLER: Semi-Implicit Method for Pressure-Linked Equations Revised) ...
1999-09-01
International Nuclear Information System (INIS)
When exposure-calibrated ionization chambers are used to calibrate megavoltage X-ray and electron beam therapy machines, the calibration factor can be divided into a chamber-dependent and a chamber-independent component. Until recently, only the chamber-independent part, which has been derived theoretically, has been used; the chamber-dependent component has been ignored. Recent experimental and theoretical considerations, however, have indicated that the dependent component must be taken into account and can affect the calibration by as much as 4%. The calibration can change due to (i) the thickness of the chamber wall, (ii) the chamber wall composition, i.e. whether the chamber is constructed of air-equivalent material, or tissue- or water-equivalent material, and (iii) the size of the chamber changing the displacement factor. Theoretical and experimental evidence indicates that the third factor varies from approximately 4.5% for "6"0Co ...
International Nuclear Information System (INIS)
Thermoluminescence (TL) and Electron Paramagnetic Resonance (EPR) dosimetry were used to measure dose effects in borosilicate glass with time, from 10 minutes to #approx#60 days following exposure to a dose of up to 10,000 Rad. TL and EPR results were consistent and performed similarly, with both techniques capable of achieving an estimated limit of detection of between 50-100 Rad. Three peaks were identified in the TL glow curve at roughly 110 C, 205 C, and 225 C. The intensity of the 205 C peak was the dominant peak over the time period of this study. The stability of all of the peaks with time since irradiation increased with their corresponding temperature and little or no variation was observed in the glow curve response to a specified total dose attained at different dose rates. The intensity of the 205 C peak decreased logarithmically with time regardless of total dose. Based upon a conservative limit of detection of 330 Rad, a 10,000 Rad dose would still be ...
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study was to assess the effect of adenosine-triphosphate (ATP) on hemodynamics and left ventricular (LV) function, and to examine the value of ATP radionuclide-ventriculography (RNVG) for detecting coronary artery disease (CAD) in comparison with standard exercise RNVG. Thirty-eight consecutive patients with suspected CAD underwent ATP (0.18 mg/Kg/min) RNVG and symptom-limited exercise RNVG. Coronary angiography revealed 27 patients with CAD (Group S) and 11 without CAD (Group N). In group S, exercise induced an increase in LV end-diastolic volume (LVEDV) and LV end-systolic volume (LVESV), and a decrease in LV ejection fraction (LVEF). In contrast, ATP infusion caused LVESV to decrease in both groups, improving LVEF. Only 14 of 39 segments whose wall motion was deteriorated by exercise showed worsening regional wall motion during ATP infusion. The sensitivity and specificity of ATP RNVG for detecting ...
1995-07-01
Optimization of Cs deposition in the 1/3 scale hydrogen negative ion source for LHD-NBI system
Energy Technology Data Exchange (ETDEWEB)
A compact cesium deposition system was used for direct deposition of cesium atoms and ions onto the inner surface of the 1/3 scale Hydrogen Negative Ion Source for the LHD-NBI system. A small, well defined amount of cesium deposition in the range of 3-200 mg was tested. Negative ion extraction and acceleration were carried out both in the pure hydrogen operation mode and in the cesium mode. Single Cs deposition of 3-30 mg to the plasma chamber have produced temporary 2-5 times increases of H-yield, but the yield was decreased within several discharge pulses to the previous steady-state value. Two consecutive 30 mg depositions done within a 3-5 hours/60 shot interval, produced a similar temporary increase of H-beam, but reached a larger H-yield steady-state value. Deposition of larger 0.1-0.2 g Cs portions with a 20-120 hours/150-270 shot interval improved the H-yield for a long (2-5 days) period of operation. Directed depositions of Cs to the ...
1999-12-01
Influence of Hexagenia on the fate and bioavailability of contaminants in sediment
International Nuclear Information System (INIS)
The influence of sediment dwelling macroinvertebrates on fate and bioavailability of contaminants in freshwater systems was determined using the burrowing mayfly, Hexagenia limbata, as a representative benthic organism. Two series of experiments were conducted: the first to determine the effect of mayflies on movement of contaminants into sediment and organisms, and the second to examine the effect of mayflies on release of contaminants from sediments to the water column and their subsequent accumulation in fish. Concentrations of "1"4C labelled DDT, hexachlorobenzene (HCB), and dihexylphthalate (DHP) in water were 0.11 +/- 0.01, 0.062 +/- 0.005 and 0.006 +/- 0.007 ppb, respectively. Total mass of DHP in the burrow wall was about equal to mass on the surface, indicating that mayflies were capable of doubling the amount of DHP sorbed per unit surface area of sediment. Adsorption of contaminants from water pumped through mayfly burrows increased ...
Glass Furnace Combustion and Melting Research Facility.
Energy Technology Data Exchange (ETDEWEB)
The need for a Combustion and Melting Research Facility focused on the solution of glass manufacturing problems common to all segments of the glass industry was given high priority in the earliest version of the Glass Industry Technology Roadmap (Eisenhauer et al., 1997). Visteon Glass Systems and, later, PPG Industries proposed to meet this requirement, in partnership with the DOE/OIT Glass Program and Sandia National Laboratories, by designing and building a research furnace equipped with state-of-the-art diagnostics in the DOE Combustion Research Facility located at the Sandia site in Livermore, CA. Input on the configuration and objectives of the facility was sought from the entire industry by a variety of routes: (1) through a survey distributed to industry leaders by GMIC, (2) by conducting an open workshop following the OIT Glass Industry Project Review in September 1999, (3) from discussions with numerous glass engineers, scientists, and executives, and (4) during visits to ...
2004-08-01
Walled-off pancreatic necrosis
UK PubMed Central (United Kingdom)
Walled-off pancreatic necrosis (WOPN), formerly known as pancreatic abscess is a late complication of acute pancreatitis. It can be lethal, even though it is rare. This critical review provides an overview...Full Text Available
2010-04-14
Thermal energy considerations on solar cavity wall building
Energy Technology Data Exchange (ETDEWEB)
The dwelling is equipped with solar collectors which heat the air circulating in the cavity walls and the space beneath the floors. The thermal aspects of such a building are described. Heat balance, losses, heating by the sun in different seasons are described. Different measures taken to reduce the energy losses are described.
1983-02-01
UK PubMed Central (United Kingdom)
The fungal pathogen Candida albicans is one of the leading causative agents of death in immunocompromised individuals. It harbors an arsenal of cell wall anchored factors that are implicated...Full Text Available
2011-01-01
Sealant tests to control radon emanation in a uranium mine. Open file report sep 79-dec 81
International Nuclear Information System (INIS)
This report describes a field-test program to determine the effectiveness of a polymeric wall sealant to reduce the escape of naturally occurring radioactive gas radon from the walls of an underground uranium mine into the ventilation air.
UK PubMed Central (United Kingdom)
The objective of this study was to determine if inflammatory tolerance and enhancement of innate immune function could be induced by the gram-positive cell wall component peptidoglycan (PGN)....Full Text Available
2008-10-01
Poland's anomaly. Natural history and long-term results of chest wall reconstruction in 33 patients.
UK PubMed Central (United Kingdom)
Poland's anomaly is an uncommon congenital aberration of the chest wall characterized by absence of the pectoralis major muscle and other nearby musculoskeletal components. In this series, a wide spectrum...Full Text Available
1988-12-01
Mapping strain exerted on blood vessel walls using deuterium double-quantum-filtered MRI
UK PubMed Central (United Kingdom)
A technique is described for displaying distinct tissue layers of large blood vessel walls as well as measuring their mechanical strain. The technique is based on deuterium double-quantum-filtered (DQF)...Full Text Available
1998-04-14
UK PubMed Central (United Kingdom)
Blunt chest-wall trauma is common; however, resultant tricuspid valve rupture is rare and can be subtle in its presentation. Transthoracic echocardiography plays a key role in diagnosis.Herein,...Full Text Available
2009-01-01
UK PubMed Central (United Kingdom)
BackgroundClinical studies suggest that local wall shear stress (WSS) patterns modulate the site and the progression of atherosclerotic lesions. Computational fluid dynamics (CFD)...Full Text Available
Ewing's sarcoma: a neuroectodermal tumor of the chest wall
International Nuclear Information System (INIS)
Ewing's sarcoma is the second most common malignant bone tumor in children and young adults. It is most prevalent between the ages of 10 and 15 years. There are present two cases of Ewing's sarcoma of the chest wall. The clinical, radiological and pathological features are described and the therapeutic options are discussed. (Author)
Effects of Multivalent Cations on Cell Wall-Associated Acid Phosphatase Activity
UK PubMed Central (United Kingdom)
Primary cell walls, free from cytoplasmic contamination were prepared from corn (Zea mays L.) roots and potato (Solanum tuberosum) tubers. After EDTA treatment, the...Full Text Available
1988-09-01
UK PubMed Central (United Kingdom)
BackgroundDuring normal breathing, the mesothelial surfaces of the lung and chest wall slide relative to one another. Experimentally, the shear stresses induced by...Full Text Available
2008-10-01
A Model for Predicting Ionic Equilibrium Concentrations in Cell Walls 1
UK PubMed Central (United Kingdom)
Purified cell walls were prepared from roots of Horse bean (Vicia faba L., var. minor) and Yellow Lupine (Lupinus luteus L.). Two methods were used:...Full Text Available
1981-08-01
A General Model of the Resistive Wall Instability in Linear Accelerators
Energy Technology Data Exchange (ETDEWEB)
A general model for wakefield-generated instabilities in linear accelerators, originally developed for cumulative beam breakup [1], is applied to the resistive wall instability. The general solution for various bunch charge distributions and application to various accelerator configurations are presented.
2007-01-08
International Nuclear Information System (INIS)
The International Atomic Energy Agency has initiated a co-ordinated research programme on implementation of base-isolation for nuclear structures. This paper discusses two areas relevant to modelling elastomeric base-isolators. These are the use of simplified models to predict the response of isolated structures to earthquake inputs and finite element analysis for calculating the stress distributions within the isolators. In the former, a curvilinear hysteretic model of the high damping natural rubber able to accommodate the stiffening of the rubber at large shear deflections is presented. Its predictions of structural accelerations and bearing displacement produced by design earthquakes and those above the design level are compared with those using a linear spring and dashpot model. A comparison has been made between two finite element analyses using MARC and ABAQUS of the force-deformation behaviour of a single disc of rubber bonded on both sides. The disc was ...
1996-05-27
A phenomenological finite element model of stereolithography processing
Energy Technology Data Exchange (ETDEWEB)
In the stereolithography process, three dimensional parts are built layer by layer using a laser to selectively cure slices of a photocurable resin, one on top of another. As the laser spot passes over the surface of the resin, the ensuing chemical reaction causes the resin to shrink and stiffen during solidification. When laser paths cross or when new layers are cured on top of existing layers, residual stresses are generated as the cure shrinkage of the freshly gelled resin is constrained by the adjoining previously-cured material. These internal stresses can cause curling in the compliant material. A capability for performing finite element analyses of the stereolithography process has been developed. Although no attempt has been made to incorporate all the physics of the process, a numerical platform suitable for such development has been established. A methodology and code architecture have been structured to allow finite elements to be birthed (activated) ...
1996-03-01
Single-Walled Carbon Nanotubes Targeted to the Tumor ...
... 1981. Retention of diphenyls, terphenyls, phenylalkanes and fluorene on graphitized thermal carbon black. Chromatographia 14:510-514. ...
2009-09-01
Physical and Computational Investigation of the Wall Pressure ...
... Although other authors had made cross-spectral density measurements, Corcos pointed to the importance of this function as indicative of the true ...
1990-04-26
Status of he-cooled divertor development (PPCS subtask TW4-TRP-001-D2)
International Nuclear Information System (INIS)
Within the framework of the EU power plant conceptual study (PPCS), helium-cooled modular divertor concepts have been investigated in detail at the Forschungszentrum Karlsruhe during the past few years. The first conceptual design proposed was based on convective cooling with the use of flow promoters in the form of pin and/or slot arrays (HEMP/HEMS) to increase the cooling surface and, hence, enhance the heat transfer capacity. While continuing the design optimisation, an advanced multiple-jet design (HEMJ) was introduced, which is based on direct jet-to-wall impinging cooling and offers advantages in terms of simple construction and manufacturing. Main emphasis of the 2004 work program (TW4-TRP-001) lay on experiments for the concepts HEMJ and HEMS, which were mainly performed at the Efremov Institute in St. Petersburg, Russia. For experiment preparation, detailed test programs were worked out and accompanying CFD analyses were accomplished. ...
British Library Electronic Table of Contents (United Kingdom)
Emerging evidence suggests that E3 ligases play critical roles in diverse biological processes, including innate immune responses in plants. However, the mechanism of the E3 ligase involvement in plant innate immunity is unclear. We report that a rice gene, OsBBI1, encoding a RING finger protein with E3 ligase activity, mediates broad-spectrum disease resistance. The expression of OsBBI1 was induced by rice blast fungus Magnaporthe oryzae, as well as chemical inducers, benzothiadiazole and salicylic acid. Biochemical analysis revealed that OsBBI1 protein possesses E3 ubiquitin ligase activity in vitro. Genetic analysis revealed that the loss of OsBBI1 function in a Tos17-insertion line increased susceptibility, while the overexpression of OsBBI1 in transgenic plants conferred enhanced resi...
2011-01-01
Reduced-aspect-ratio stellarator reactors
Energy Technology Data Exchange (ETDEWEB)
The extent to which the size of a modular stellarator reactor may be reduced is investigated by means of an analytic model of the reactor. The various means employed include varying the blanket/shield thickness, the power output and the wall loading. An optimum design is found, the major radius of which tends to be insensitive to changes in these quantities, although a decrease in the power output leads to a rather smaller decrease in reactor dimensions, as would be expected. Varying the plasma beta at fixed (iota/2..pi..)/sup 2/epsilon or, alternatively, increasing the rotational transform per field period, may, however, allow configurations with fewer field periods to be accessed which have a substantially smaller major radius than the 'standard case' adopted. The magnetics of various configurations required by the model are checked by field line following and the performance claimed is shown to be relatively easily ...
1984-01-01
Energy Technology Data Exchange (ETDEWEB)
The study of natural convection flow and heat transfer within a cylindrical annulus has received considerable attention because of its numerous applications, such as in nuclear reactor design, electronic component cooling, thermal storage systems, energy conservation, energy storage, and energy transmission. Here, the effects of multiple geometric perturbations on the inner and outer cylinders of an annulus with impermeable end walls are investigated in this work. A three-dimensional study was done using a numerical scheme based on a Galerkin method of finite element formulation. The nature of the buoyancy-induced flow field has been analyzed in detail. The flow fields for the cases considered were found to be qualitatively similar, and the introduction of each additional perturbation altered the flow field in a regular and recurring manner. The introduction of each perturbation on the outer cylinder causes clockwise and counterclock-wise rotating patterns on ...
1999-05-14
International Nuclear Information System (INIS)
The study of natural convection flow and heat transfer within a cylindrical annulus has received considerable attention because of its numerous applications, such as in nuclear reactor design, electronic component cooling, thermal storage systems, energy conservation, energy storage, and energy transmission. Here, the effects of multiple geometric perturbations on the inner and outer cylinders of an annulus with impermeable end walls are investigated in this work. A three-dimensional study was done using a numerical scheme based on a Galerkin method of finite element formulation. The nature of the buoyancy-induced flow field has been analyzed in detail. The flow fields for the cases considered were found to be qualitatively similar, and the introduction of each additional perturbation altered the flow field in a regular and recurring manner. The introduction of each perturbation on the outer cylinder causes clockwise and counterclock-wise rotating patterns on ...
1999-05-14
Energy Technology Data Exchange (ETDEWEB)
Safety and environmental assessments have been made of conceptual fusion power plant designs employing silicon carbide composites (SiC/SiC) as the first wall and blanket structure material. These have used similar analysis methods to earlier studies of designs based on vanadium alloy or low-activation martensitic steel, allowing direct comparisons. The very low short-term activation of silicon carbide results in an almost insignificant level of decay heat in postulated loss of coolant accidents, and a lower {gamma}-dose rate on the timescale of relevance to handling for maintenance operations. However on the longer time-scale, of interest in possible recycling operations, decommissioning and waste management, SiC/SiC appears to perform no better than vanadium alloy or low-activation martensitic steel, due in part to the activation of impurities in a realistic composition. Furthermore, its increased neutron transparency may result in higher ...
2001-04-01
International Nuclear Information System (INIS)
The primary aim was to evaluate delayed contrast-enhanced MRI in depicting perineural spread of hilar cholangiocarcinoma (CCC) and consequently to determine the capability of MRI/MRCP for staging CCC. Fifteen patients that underwent MRI/MRCP and surgical treatment were retrospectively included. Two radiologists evaluated MR images to assess delayed periductal enhancement, extent of bile duct stenosis, liver parenchymal and vascular involvement and presence of liver atrophy. An agreement between delayed enhancement of the bile duct walls and perineural neoplastic spread showed a very good correlation factor (0.93). The overall accuracy in detecting biliary neoplastic invasion was higher for delayed T1-weighted images (93.3%) than for the MRCP images (80%), and T1-delayed image increased the MR accuracy in assessing the neoplastic resectability (p < 0.05). MRI correctly predicted vascular involvement in 73% and liver involvement in 80% of the ...
2008-10-01
British Library Electronic Table of Contents (United Kingdom)
This research aims to investigate the effects of chemical blowing agent (CBA) contents and particle sizes on the properties of foamed poly(vinyl chloride) (PVC)/rice hull (RH) composites. Fine particles of azodicarbonamide (AC) at 5, 8, 11 and 22mm were modified with 20% by weight of ZnO and used at 0-3.0% by weight. The average cell size and density of the PVC/RH foamed profiles were reduced as the content of modified azodicarbonamide (mAC) increased. Larger mAC particles lowered the density more effectively. Maximum reduction of density by 46% was achieved when mAC 22mm was applied at 2.0% by weight. Larger blowing particles led to PVC/RH foam with greater flexural modulus and strength. Greater impact strength, observed when 5mm mAC was applied, resulted from the rather thick cell wall c...
2011-01-01
Impact of radiation measurements on hardening of TFTR diagnostics
International Nuclear Information System (INIS)
Contrary to previous plans for the preparation of diagnostic systems for D-T break-even experiments in the Tokamak Fusion Test Reactor (TFTR), it now appears that a limited Q#approx#1 demonstration can be carried out without constructing a close-fitting igloo radiation shield around the tokamak. In order to assess the impact of D-T operation of TFTR without an igloo shield, particularly with regard to hardening of diagonstic systems, we have mapped neutron and gamma fluxes inside the test cell and test cell basement, using a variety of radiation measurements. The measurements are sufficiently detailed to resolve massive hardware components, such as neutral beams and shielded diagnostic systems, and can be used to predict local fluxes. By comparing the measurements with transport code calculations for the case of a bare tokamak, we conclude that the models have substantially overestimated fluxes both inside and outside the TFTR shield walls. It may be possible to ...
Fuel assembly and reactor core
International Nuclear Information System (INIS)
In a fuel assembly having moderator rods, an axial average value of a ratio between the total of the lateral cross sectional area of a portion to be filled with moderators and the total of the lateral cross sectional area of fuel pellets is determined as greater than 0.4, a lateral cross sectional area of a portion to be filled with moderators per one moderator rod is determined as from 14 to 50cm"2 and the ratio between the total of the lateral cross sectional area of moderators and a total of the lateral cross sectional area of fuel pellets in a horizontal cross section is determined as from 2.7 to 3.4. Since the axial average value for lateral cross sectional area of a portion to be filled with moderators/lateral cross sectional area of fuel pellets is determined as #>=# 0.4, the lateral cross sectional area of moderators of moderator rods is increased, the lateral cross sectional area of a gap water region is decreased to reduce the value of local power ...
1992-12-03
Energy Technology Data Exchange (ETDEWEB)
A unique method, previously proposed by the author, was applied to the heat transfer augmentation in the flow boiling field. In this method a screen sheet was put on the horizontal heated surface where bubble nucleation occurred. Generated vapor bubbles were trapped between the screen and the wall, became flat and moved along the surface. This restricted bubble behavior caused the heat transfer enhancement. Three types of the screen were tested in the present experiment and the effect of the screen was investigated on the heat transfer and two-phase flow characteristics. In two cases of them, the screen was displaced upward by the bubble nucleation. Compared with the ordinary flow boiling case, heat transfer was enhanced by a factor of 1.2 to 6 within the present experimental range. By using a simple flow model, it was made clear that the effect of the height of the displaced screen was important to evaluate the increase in pressure drop. ...
2000-03-25
Energy Technology Data Exchange (ETDEWEB)
An experimental study of forced convection heat transfer at the inner tube wall of a double pipe heat exchanger with coiled wire inserts as heat transfer augmentation devices was performed over a turbulent flow region. The test results from twelve augmented tubes with inserts of different combinations of wire diameters (0.813, 1.016 and 1.575 mm) and pitches (2.82, 3.63, 5.08 and 8.47 mm) indicate that the turbulence promoters studied improve heat transfer by a factor of 1.4 to 2.24 compared with a smooth tube, although at a cost of 10-30 times increase in friction factor. A formula for presenting dimensionless exergy losses in a tubular heat exchanger is derived first and then the thermohydrodynamic optimum instead of economic optimum is found by minimizing the exergy losses in the system. From the heat transfer improvement number defined, it is observed that coiled wire turbulence promoters are more effective at Reynolds numbers less than ...
1992-12-01
International Nuclear Information System (INIS)
68 replaced carbon steel piping in secondary system of pressurized water reactor (PWR) has been investigated by visual examination for checking thinning conditions. It is well known that the flow-accelerated corrosion (FAC) was inhibited by traces of Cr in steel. Therefore, the chemical compositions of those steels have been measured. In addition, the micro structure and hardness of those steels have been investigated. And the relationship between those material variables and FAC rate was considered. As the results, (1) The Cr contents in those steels were below 0.1 wt% except one sample. Minute quantities of chromium increase the resistance against FAC. But the water velocity was thought to be the dominant factor rather than chemical composition in steel, at least such as below 0.1%Cr. (2) Hardness of all piping has been satisfied the specifications of each materials. The hardness of steels was not correlated with wall thinning rate. (3) The ...
2008-10-01
Development of a phoswich detector to detect neutrons in the charged-particle mixed field
Energy Technology Data Exchange (ETDEWEB)
Manned-space missions bring an exposure due to corpuscular radiations of which nature is quite different from what we encounter in the ground environment. In the space environment, many secondaries are produced through interactions of cosmic ray primaries with the spacecraft wall and other surrounding materials. Among this large variety of radiation components in the space, the contribution of neutrons to the radiation exposure of astronauts has remained to be studied. Up to today, efforts to measure neutron dose equivalent have been made using passive detector systems. Considering uncertainties involved in current measurements and estimations of high energy neutrons, and their increasing importance for future manned missions, it is necessary to measure neutron spectrum in the spacecraft under realistic conditions. The neutron spectra have never been measured on board a spacecraft, because the neutron measurement requires to discriminate ...
1997-07-01
Commercializing research: the leadership challenges for the 21st century
International Nuclear Information System (INIS)
R and D today is a large industry that consumes vast amounts of public and private funds in most countries. It is becoming increasingly evident that technology transfer and the commercialization of research done at universities and government funded research laboratories must be a key element of their comprehensive strategic plan. It involves using a verified and organized knowledge and research to develop commercially viable products. It requires a visionary leader with effective project management skills to manage and motivate a team of scientists and engineers, otherwise even a top rated researcher will enervate and wither within the walls of research laboratories. This paper will highlight the importance, challenges and techniques of commercializing technology from accelerator research laboratories. It will provide an overview of the requirements of scientific leadership for both commercialization of research and technology, together with ...
2000-06-26
Brazilian onshore pipelines rehabilitation program
Energy Technology Data Exchange (ETDEWEB)
Brazil currently has an oil and transport system with approximately 15,000 km of pipeline. However, energy needs are now increasing due to rapid population growth and expanding industrial activities in the country. This paper provided details of a pipeline rehabilitation program conducted across 424 km of pipeline in northeastern Brazil. The pipeline crossed 32 municipal districts. Over 37 replacements and upgrades were completed as part of the rehabilitation program. Surveys were completed to verify depth of pipeline cover, as well as to examined the condition of the external pipe coating, and the operational status of the cathodic protection (CP) system. Shutdown of the pipeline was completed during a 14 hour period, and included depressurization, cutting work, welding, and repressurization. Services included pigging to evaluate pipe-wall thickness; corrosion section replacement; an investigation of class locations during the operating life ...
2004-07-01
Unsteady flow of an incompressible fluid in a horizontal porous medium with suction
International Nuclear Information System (INIS)
A theoretical analysis of two-dimensional unsteady flow in a porous medium bounded by a horizontal wall is presented as a perturbation on a basic flow. It is assumed that the perturbation is occasioned by a sudden suction at the wall. Even for a highly permeable medium the characteristic Reynolds number in porous media flow is usually small and asymptotic solutions are developed by the Laplace transform technique. It is observed that the perturbed shear stress at the wall decays exponentially with time. (author). 5 refs.
2000-03-01
Energy Technology Data Exchange (ETDEWEB)
Results of an investigation made to develop methods of making iron castings having wall thicknesses as small as 2.5 mm in green sand molds are presented. It was found that thin wall ductile and compacted graphite iron castings can be made and have properties consistent with heavier castings. Green sand molding variables that affect casting dimensions were also identified.
2001-10-31
Survey of naturally radioactive level of some new type wall materials
International Nuclear Information System (INIS)
Naturally occurring radioactive materials (NORM) in seven new type wall materials were surveyed. The radioactivity was determined with HPGe-#gamma# spectrometer. The red mud has the highest radioactivity concentration, followed by slag building blocks, fly-ash building blocks (bricks), gangue bricks and light weight board materials, gypsum blocks. Fly-ash and slag contain higher NORM, which contributes the major part of the radioactivity in new wall materials. (authors)
2006-09-01
Polymer depletion-induced slip near an interface
Energy Technology Data Exchange (ETDEWEB)
A quantitative description is proposed for the depletion-induced slip thickness and velocity profile of a polymer solution near the wall-fluid interface in simple shear flow. The inhomogeneous polymer density profile at a flat wall is inserted into the equations of motion for the flow of a polymer solution near the flat wall. The theory is in quantitative agreement with simulation results. (letter to the editor)
2005-01-19
Modelling of the wall jet in a direct injection diesel engine
Energy Technology Data Exchange (ETDEWEB)
As a part of a phenomenological model, a method for simulating the wall/jet interaction in a direct injection diesel engine is proposed. The method is based on the application of the momentum conservation equation in the different directions in which the wall jet is spread, and takes into account both the interaction with the combustion chamber geometry and with swirl. It takes as initial conditions the results of calculating the free jet, which is divided into packages. The predictions provide good agreement with those by other researchers. (author).
1992-01-01
A device for assemblying a support string for an offshore drilling rig
Energy Technology Data Exchange (ETDEWEB)
The purpose of the invention is to simplify assembly and to reduce labor intensity. This is achieved by the fact that the assembly shaft is positioned in a hawser, while its wall which is turned towards the body of the installation is combined with the hawser wall, where a U shaped opening is made in the wall of the assembly shaft, along the edges of which there is a hermetically sealing device, while the bottom of the body of the offshore drilling rig is equipped with a rigid insert attached with the capability of adjoining it with the hermetically sealing device.
1983-01-01
Three-dimensional, three-component wall-PIV
Energy Technology Data Exchange (ETDEWEB)
This paper describes a new time-resolved three-dimensional, three-component (3D-3C) measurement technique called wall-PIV. It was developed to assess near wall flow fields and shear rates near non-planar surfaces. The method is based on light absorption according to Beer-Lambert's law. The fluid containing a molecular dye and seeded with buoyant particles is illuminated by a monochromatic, diffuse light. Due to the dye, the depth of view is limited to the near wall layer. The three-dimensional particle positions can be reconstructed by the intensities of the particle's projection on an image sensor. The flow estimation is performed by a new algorithm, based on learned particle trajectories. Possible sources of measurement errors related to the wall-PIV technique are analyzed. The accuracy analysis was based on single particle experiments and a three-dimensional artificial data set ...
2010-06-15
Energy Technology Data Exchange (ETDEWEB)
With the combination of source ventilation and ceiling cooling for air-conditioning of working and recreation rooms, a ventilation system is available which fulfills the highest demands regarding thermal comfort. In order to utilize the advantages of this ventilation system with regard to air quality and thermal comfort to an optimum, the influence of the radiation exchange between cooling ceiling and walls on the flow in the room is investigated experimentally. Energy transfer from the walls to the cooled ceiling may result in an insufficient temperature of the walls compared to ambient air and in an upward flow on the wall surfaces (downward flow of) driven by gravity, which influences the flow pattern in the case of source ventilation. (orig.)
1993-07-01
British Library Electronic Table of Contents (United Kingdom)
Following Hurricane Katrina, the study of cantilevered sheet pile I-wall with gap or partial gap has become one of the central elements of the ongoing investigation pertaining to the re-building of hurricane protection systems in New Orleans, LA. Historically, the US Army Corps of Engineers (USACE) had mostly relied upon the Method of Planes (MOP) analysis procedure for slope stability analysis of I-wall systems. However MOP is a simplified procedure which does not satisfy total equilibrium. Nevertheless, MOP is still considered by USACE as a popular analysis tool because of its simplicity and ease of use in slope stability analysis. This paper demonstrates the applicability and suitability of MOP as a viable analysis tool for the analysis of New Orleans I-wall founded on layered cohesive ...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The problem during the continuous idling operation of diesel engine is about the time increase in emission of HC (hydrocarbon which is not burned yet) into the atmosphere. A pilot injector having been developed, the time increase in HC emission was studied in order to ameliorate the combustion during the idling. An engine and spray unit were used with the above developed pilot injector for the experiment. Three types of injector were also used for the comparison purpose. Investigation was made of penetration characteristics of spray on the pump tester in the atmosphere, locally averaged droplet size distribution inside the spray, both droplet size and velocity distributions, and emission characteristics by the mounting test onto the engine. The developed pilot injector was most effective in controlling the HC emission. The time increase in HC emission is attributable to the adhering quantity of carbon. The adhering of ...
1992-10-01
Energy Technology Data Exchange (ETDEWEB)
The puborectalis syndrome is a defecation disorder supported by the nonrelaxation of puborectalis sling with consequent dyschezia. They report on a series of 98 patients submitted to clinical examination, defecography, anorectal manometry, electromyography and intestinal transit time studies. The main symptoms of puborectalis syndrome in their patients were incomplete defecation (89 %) and intermittent evacuation (63 %); 28 % of patients turned to finger defecation. In all patients, defecography showed an abnormal increase in puborectalis impression on the posterior anorectal wall, reduced anorectal angle opening under straining (mean value: 113 deg) and prolonged expulsion time with barium pooling in the ampulla (mean evacuation time: 38 seconds). Such anorectal abnormalities as rectal mucosal prolapse (47 cases) and anterior rectocele (36 cases) were also associated. In 33 of 98 patients (34 % of cases), sling assessment by bidigital ...
1997-04-01
Defecographic diagnosis of the puborectalis syndrome
International Nuclear Information System (INIS)
The puborectalis syndrome is a defecation disorder supported by the nonrelaxation of puborectalis sling with consequent dyschezia. They report on a series of 98 patients submitted to clinical examination, defecography, anorectal manometry, electromyography and intestinal transit time studies. The main symptoms of puborectalis syndrome in their patients were incomplete defecation (89 %) and intermittent evacuation (63 %); 28 % of patients turned to finger defecation. In all patients, defecography showed an abnormal increase in puborectalis impression on the posterior anorectal wall, reduced anorectal angle opening under straining (mean value: 113 deg) and prolonged expulsion time with barium pooling in the ampulla (mean evacuation time: 38 seconds). Such anorectal abnormalities as rectal mucosal prolapse (47 cases) and anterior rectocele (36 cases) were also associated. In 33 of 98 patients (34 % of cases), sling assessment by bidigital ...
Carbon dioxide absorption with aqueous potassium carbonate promoted by piperazine
Energy Technology Data Exchange (ETDEWEB)
This paper presents thermodynamic and kinetic data collected for aqueous blends of piperazine (PZ), an ethylamine, and potassium carbonate (K{sub 2}CO{sub 3}). Mixtures of K{sup +} and PZ have been investigated in a wetted-wall column at 40 to 80{sup o}C, typical conditions for an industrial absorber. The addition of 0.6 m PZ to 20 wt% (3.6 m) K{sub 2}CO{sub 3} increases the rate of CO{sub 2} absorption by a factor of ten from the value in unpromoted solutions at 60{sup o}C. The addition of PZ increases the heat of absorption from 4 kcal/mol in 3.6 m K{sup +} to 10 kcal/mol when 0.6 m PZ is added. The capacity, ranging from 0.4 to 0.7 mol-CO{sub 2}/kg-H{sub 2}O, approaches that of monoethanolamine (MEA) solutions and seems to be a strong function of K{sup +} concentration. Speciation of the solution was obtained using proton nuclear magnetic reasonance (NMR), verifying and quantifying the presence of three PZ species. An ...
2003-07-01
Altered glycosaminoglycan metabolism in injured arterial wall
Energy Technology Data Exchange (ETDEWEB)
Glycosaminoglycans (GAG) are believed to be important in the pathogenesis of atherosclerosis. We have previously demonstrated that areas of injured aorta that have been re-endothelialized accumulate increased amounts of lipid and GAG when compared to areas remaining de-endothelialized. We have now examined the net incorporation of labeled precursors into the individual GAG present in both re-endothelialized and de-endothelialized areas of rabbit aorta. Aortic tissue was examined at 2-3 and 10-14 weeks after a denuding injury by incubating tissue minces with (/sup 3/H)glucosamine and sodium (/sup 35/S)sulfate for 24 hr. Following incubation, the aortic GAG were isolated and assayed for uronic acid concentration and radioactivity. Results indicate that the total GAG concentration was significantly greater in the re-endothelialized as compared to de-endothelialized areas. The concentration in uninjured aorta was 9.01. The difference between the injured tissues was ...
1985-06-01
Unsteady state heat transfer in the vertical walls of a building
Energy Technology Data Exchange (ETDEWEB)
The unsteady state heat transfer behaviour of a vertical wall subject to the effects of uniform radiation is investigated and the dimensional analysis of combined heat transfers by conduction, convection and radiation is presented. The convective heat transfer coefficients used in the numerical model are determined experimentally by means of an assembly resembling the conditions encountered in the dwelling (variable temperatures and heat flows in time and space, wall associated with a floor, radiative flux outside the wall). In routine conditions (homogeneous wall dimensions, temperature differentials less than 40/sup 0/C), it is shown that the problem depends in practice on three parameters (instead of five) and that nomographs can give the energy accumulated in the wall as a function of its geometric and thermal charactersitics and the external conditions (type and thickness of ...
1982-12-01
CFD Application to the Regulatory Assessment of FAC-Caused CANDU Feeder Pipe Wall Thinning Issue
Energy Technology Data Exchange (ETDEWEB)
From the results of the In-Service Inspection (ISI) measuring the wall thickness of outlet (hot-leg side) feeder pipes performed at two Canadian nuclear power plants, Point Lepreau and Gentilly-2 in 1995 and 1996, respectively, the wall thinning degradation of feeder pipes at the bend part was found to be much more severe than expected. It has been well known that such wall thinning of feeder pipes is caused by the flow accelerated corrosion (FAC) which is one of the mechanical-chemical degradation mechanisms affecting the integrity of piping systems. For the Wolsung unit 1, the wall thickness measurements have been performed during every overhaul period since 1996. The wall thinning rates at the bends of outlet feeder pipes were assessed to exceed the design value. However, for the Wolsung units 2, 3 and 4, the wall thinning rates of all the outlet feeder pipes ...
2007-07-01
CFD Application to the Regulatory Assessment of FAC-Caused CANDU Feeder Pipe Wall Thinning Issue
International Nuclear Information System (INIS)
From the results of the In-Service Inspection (ISI) measuring the wall thickness of outlet (hot-leg side) feeder pipes performed at two Canadian nuclear power plants, Point Lepreau and Gentilly-2 in 1995 and 1996, respectively, the wall thinning degradation of feeder pipes at the bend part was found to be much more severe than expected. It has been well known that such wall thinning of feeder pipes is caused by the flow accelerated corrosion (FAC) which is one of the mechanical-chemical degradation mechanisms affecting the integrity of piping systems. For the Wolsung unit 1, the wall thickness measurements have been performed during every overhaul period since 1996. The wall thinning rates at the bends of outlet feeder pipes were assessed to exceed the design value. However, for the Wolsung units 2, 3 and 4, the wall thinning rates of all the outlet feeder pipes ...
2007-05-10
Energy Technology Data Exchange (ETDEWEB)
This work proposes an innovative blend of potassium carbonate (K{sub 2}CO{sub 3}) and piperazine (PZ) as a solvent for CO{sub 2} removal from combustion flue gas in an absorber/stripper. The equilibrium partial pressure and the rate of absorption of CO{sub 2} were measured in a wetted-wall column in 0.0 to 6.2 m K{sup +} and 0.6 to 3.6 m PZ at 25 to 110 C. The equilibrium speciation of the solution was determined by {sup 1}H NMR under similar conditions. A rigorous thermodynamic model, based on electrolyte non-random two-liquid (ENRTL) theory, was developed to represent equilibrium behavior. A rate model was developed to describe the absorption rate by integration of eddy diffusivity theory with complex kinetics. Both models were used to explain behavior in terms of equilibrium constants, activity coefficients, and rate constants. The addition of potassium to the amine increases the concentration of CO{sub 3}{sup 2-}/HCO{sub 3}{sup -} in ...
2005-04-18
Energy Technology Data Exchange (ETDEWEB)
Plasma arc welding processes are used in off-shore industry for construction and maintenance in the wet surrounding of underwater structures and pipelines. In greater water depth the density of the plasma gas increase because of the greater hydrostatic pressure. This causes the increase of conductive heat losses to the wet surrounding. To keep up the energy flux to the workpiece to be welded, the plasma arc has to burn in a local dry area with an inside pressure of 1 bar. This requirement can be fulfilled by a rotating cylinder with a liquid film flowing down the inner wall. The flow around the rotating cylinder to create a local dry area around the plasma arc under water is experimentally investigated. The rotating cylinder is placed above the work surface which is simulated by a flat plate. According to the centrifugal forces of the rotating flow inside the gap between the lower end of the cylinder and the flat plate the ...
1994-12-31
The compressive strength of cement blocks permeated with an organic phase change material
Energy Technology Data Exchange (ETDEWEB)
The authors investigate the feasibility of constructing walls and partitions with enhanced heat storage capability from cement blocks permeated with an organic phase change material (pressed stearic acid). The blocks are lightweight, easy to produce and are cured in the same way as cement or concrete. The ratio of components (cement, stearic acid (SA) and water) was optimized with respect to compressive strength. With normal portland cement, the best compressive strength 2.2 MPa was obtained with a ratio C:SA:W of 1:0.8:0.65 (i.e. 32% stearic acid) after 28 days of curing. This was increased to 4.4 MPa when high early strength cement was used, about as strong as Sipporex, lightweight concrete or lightweight clay bricks. As expected, the compressive strength decreased linearly with temperature between 25/sup 0/C and 100/sup 0/C, at a rate of 15 kPa//sup 0/C. The drying shrinkage of the modules was found to be 50% greater than for cement mortars. ...
1984-01-01
TRANSPORT CHARACTERISTICS OF REPRESENTATIVE DEBRIS IN A OPEN CHANNEL
Energy Technology Data Exchange (ETDEWEB)
During LOCA(Loss of Coolant Accident), emergency core coolant supplements form a recirculation sump and cooled core and containment. When the double ended guillotine Break (DEGB) at the hot leg near steam generator, due to the jet impingement discharge flow, the debris could be potentially generated at pipe or wall nearby steam generator and be transported to the recirculation sump. Therefore, the debris could be accumulated and be clogged in the recirculation sump screen. If debris blocked the sump screen, the pressure drop increased at the screen so as to increase the pressure loss of ECCS (Emergency Core Cooling System) pump NPSH (Net positive suction head). It is potentially influenced to decrease the long-term cooling capability of the recirculation sump. The recirculation sump screen clogging accident has happened in BWR at 1990. Considering the important of safety, US NRC published Regulatory Guide 1.82 Rev.3 ...
2010-05-15
Sump Pool Flow Simulation during Fill-up Phase of LOCA Using on CFD for OPR1000 Plant
Energy Technology Data Exchange (ETDEWEB)
During LOCA (Loss of Coolant Accident) in design bases accident (DBA), emergency core coolant supplements form a recirculation sump and cooled core and containment. When the double ended guillotine Break (DEGB) at the hot leg near steam generator, due to the jet impingement discharge flow, the debris could be potentially generated at pipe or wall nearby steam generator and be transported to the recirculation sump. Therefore, the debris, such as insulations and paint chips, could be accumulated and be clogged in the recirculation sump screen. If debris is blocked the sump strainer, the pressure drop is increased at the screen so as to increase the pressure loss of ECCS (Emergency Core Cooling System) pump NPSH (Net positive suction head). It is potentially influenced to decrease the long-term cooling capability of the recirculation sump. The recirculation sump screen clogging accident has happened in BWR of USA and Sweden. ...
2009-10-15
Shell Temperatures for a Single-Heater Diffuser
Energy Technology Data Exchange (ETDEWEB)
A new diffuser/permeator design has been proposed for a new Savannah River Site tritium project. The use of a single heater well in the center of the shell had raised concerns that the Pd/Ag coils may be shielding radiative heat transfer to the walls thus reducing Pd/Ag tube temperatures near the shell below the recommended minimum operating temperature. The diffuser was fitted with thermocouples to measure shell temperatures during testing. Tests were run with the shell evacuated, helium feed flows of 0, 1000, and 2000 sccm; bleed pressures ranging from 0 to 203 kPa, and heater temperatures of 650, 675, and 700 degrees C. Hydrogen permeation tests were run with two hydrogen/helium mixtures and feed rates to simulate 1st and 2nd stage diffuser operations. Approximately 20 hours were required to bring the diffuser from ambient temperature to steady-state conditions. For tests with a heater temperature of 675 degrees C and no hydrogen flow, helium flow rate and ...
2004-11-01
We model nongraphitized carbon black surfaces and investigate adsorption of argon on these surfaces by using the grand canonical Monte Carlo simulation. In this model, the nongraphitized surface is modeled as a stack of graphene layers with some carbon atoms of the top graphene layer being randomly removed. The percentage of the surface carbon atoms being removed and the effective size of the defect (created by the removal) are the key parameters to characterize the nongraphitized surface. The patterns of adsorption isotherm and isosteric heat are particularly studied, as a function of these surface parameters as well as pressure and temperature. It is shown that the adsorption isotherm shows a steplike behavior on a perfect graphite surface and becomes smoother on nongraphitized surfaces. Regarding the isosteric heat versus loading, we observe for the case of graphitized thermal carbon black the increase of heat in the submonolayer coverage and then a sharp ...
2006-09-01
Energy Technology Data Exchange (ETDEWEB)
The liquefaction reaction system of an NEDOL process coal liquefaction 1t/d PSU was opened and checked to investigate the cause of the rise of differential pressure between liquefaction reactors of the PSU. The liquefaction test at a coal concentration of 50 wt% using Tanito Harum coal was conducted, and it was found that the differential pressure between reactors was on the increase. By the two-phase flow pressure loss method, deposition thickness of deposit in pipelines was estimated at 4.4mm at the time of end operation, which agreed with a measuring value obtained from a {gamma} ray. The rise of differential pressure was caused by deposit formation in pipelines connecting reactors. The main component of the deposit is calcite (CaCO3 60-70%) and is the same as the usual one. It is also the same type as the deposit on the reactor wall. Ca in coal ash is concerned with this. To withdraw solid matters deposited in the reactor, there are ...
1996-10-28
Energy Technology Data Exchange (ETDEWEB)
The absorption of solar heat and the attendant thermal and mechanical loadings on the tubes of cavity receivers depend predominantly on the flux distribution of the incident solar radiation. For an axially symmetric cavity receiver with a parabolic dish collector, it is simple to determine the insolation pattern on the receiver internal surfaces if the system is ideal. In such a system the surface of the dish is perfectly parabolic (no contour flaws are present), and the sun's central ray impinges on the dish surface parallel to the focal axis (no sun tracking flaws are present). These two conditions cannot be achieved in practice, and therefore the feasible parabolic dish system is referred to as a real system although, in actual fact, it is only an approximation to any actual system. The purpose of this paper is to devise calculation principles which permit analysis of a receiver designed for ideal conditions to verify its structural adequacy under the nonideal conditions to ...
1990-11-01
Carbon dioxide absorption with aqueous potassium carbonate promoted by piperazine
Energy Technology Data Exchange (ETDEWEB)
Many commercial processes for the removal of carbon dioxide from high-pressure gases use aqueous potassium carbonate systems promoted by secondary amines. This paper presents thermodynamic and kinetic data for aqueous potassium carbonate promoted by piperazine. Research has been performed at typical absorber conditions for the removal of CO{sub 2} from flue gas. Piperazine, used as an additive in 20-30 wt% potassium carbonate, was investigated in a wetted-wall column using a concentration of 0.6 m at 40-80{sup o}C. The addition of 0.6 m piperazine to a 20 wt% potassium carbonate system decreases the CO{sub 2} equilibrium partial pressure by approximately 85% at intermediate CO{sub 2} loading. The distribution of piperazine species in the solution was determined by proton NMR. Using the speciation data and relevant equilibrium constants, a model was developed to predict system speciation and equilibrium. The addition of 0.6 m piperazine to 20 wt% potassium carbonate ...
2004-09-01
International Nuclear Information System (INIS)
Quantitative gated SPECT (QGS) was evaluated in 7 normal volunteers and 31 patients with cardiac diseases. Adequate cut off value of a prefilter was 0.45. In phantom, the left ventricular volume value was 93.9% of determined value by 180-degree projection in L type and 98.8% by 360-degree projection in opposed type. In normal volunteers, LVEF measured by QGS program related to value by first pass method. As for functional map, regional EF and wall motion decreased at the septum side, and wall thickening at base side of heart. Good correlation was recognized (p<0.0001) between blood flow image and functional map (regional EF and wall thickening). In 20 cases of acute myocardial infarction, lesion was detected conspicuously in regional EF and wall motion. The accuracy of coronary arterial stenosis improved in functional map (regional EF 92%, wall motion 92% and ...
1998-08-01
The EU HT test programme of ITER primary wall small scale mock ups
International Nuclear Information System (INIS)
This paper summarises the main results obtained so far in the frame of the EU Home Team test programme of ITER primary wall small scale mock ups. It describes briefly the fabrication method of the mock ups, the test conditions and the main results obtained with high heat flux and thermal fatigue tests of Cu alloy/stainless steel and beryllium/Cu alloy/stainless steel mock ups. The results obtained so far show good thermal fatigue performance and operation margin of the ITER primary first wall concept. (author)
1998-09-07
Main achievements of the EU HT test programme of ITER primary wall small scale mock ups
International Nuclear Information System (INIS)
This paper presents the main achievements of the European Home Team (EU HT) test programme of ITER primary wall small scale mock ups. It describes briefly the fabrication method of the mock ups, the test conditions and the main results obtained with high heat flux and thermal fatigue tests of Cu alloy/stainless steel and beryllium/Cu alloy/stainless steel mock ups. The results obtained so far show very good thermal fatigue performance and operation margin of the ITER primary first wall concept.
2000-11-01
Magnetization reversal phenomena and domain wall behaviours in nanostructured magnetic systems
International Nuclear Information System (INIS)
Several recent experiments on micro- (or nano-) structured samples of ferromagnetic materials are introduced. Magnetization reversal phenomena are investigated on submicron wire samples of trilayer structure using the giant magnetoresistance effect. Domain wall movements are sensitively monitored by resistivity measurements and the velocity of propagation is determined. The contribution of domain wall to the resistivity is argued from the results on artificially designed samples of a spring-magnet system. In circular dots of permalloy, the existence of vortex magnetization is confirmed and the reversal of the vortex core magnetization is studied from magnetic force microscopy measurements. (author)
2001-09-23
Creation of an antiferromagnetic exchange spring
We present evidence for the creation of an exchange spring in an antiferromagnet due to exchange coupling to a ferromagnet. X-ray magnetic linear dichroism spectroscopy on single crystal Co/NiO(001) shows that a partial domain wall is wound up at the surface of the antiferromagnet when the adjacent ferromagnet is rotated by a magnetic field. We determine the interface exchange stiffness and the antiferromagnetic domain wall energy from the field dependence of the direction of the antiferromagnetic axis, the antiferromagnetic pendant to a ferromagnetic hysteresis loop. The existence of a planar antiferromagnetic domain wall, proven by our measurement, is a key assumption of most exchange bias models.
2004-04-06
Conjugate parallel-flowing free and forced convection boundary layers on vertical wall sides
Energy Technology Data Exchange (ETDEWEB)
The paper describes an analytical study of two parallel-flowing boundary layers of free and forced convection modes on the facing sides of a vertical thin wall. The two layers are analyzed separately within the framework of boundary layer theory, and coupled by the matching conditions at wall. Numerical data are obtained for a wide range of a dimensionless conjugation parameter {zeta} relating the heat transfer effectiveness of two convection modes. Based on these data, an expression for calculating the conjugate mean Nusselt number as a function of {zeta}-parameter is found by means of a curve-fitting method. (orig.)
2003-02-01
Aspiration cover for the loading site of a belt conveyer
Energy Technology Data Exchange (ETDEWEB)
An aspiration cover is proposed for the site of loading a belt conveyer including a housing arranged above the belt conveyer in whose cover there is an aspiration sleeve and a discharge chute from the upper wall and a guide having a cushioning plate on the lower end. It is distinguished by the fact that in order to improve the effectiveness of removing dust by decreasing the volume of aspirated air, the cover between the aspiration sleeve and the upper wall of the loading chute is convex in the inside of the housing and has a smooth connection to the upper wall of the discharge chute turned towards the cushioning plate.
1982-01-01
WALL PRESSURE FLUCTUATIONS UNDER TURBULENT ...
... necessary to allow for the effata nr the finits size of the oressure tranaducer on both the root mean square and power spectral density measurements ...
1963-04-01
Strain Rate Effects on Ultimate Strain of Copper
... Figure 3a. PETN Filled Tube Specimen Detonated by Exploding Bridgewire Specimen POLYETIILLENE END-CAP "1- 901am WALL IHICKNESS ...
1979-05-01
Semi Annual Progress Report on BLADE END WALL FLOWS IN COMPRESSORS ...
Eckert, B., "Axial Kompressoren und Radial Kompressoren," Springer. Verlag, Berlin, 1953. 3. Lebot, Y., et al., "Theoretical and Experimental Determination ...
SPACE STATION INTEGRATED WALL DESIGN AND PENETRATION
screens of fine wire was placed between the gun barrel and the panel to determine whether the gun performance was repeatable. The transducers were placed ...
Review of Polyarylacetylene Matrices for Thin-Walled ...
... After strip- ping off the chloroform, the dibromo ethyl (EDBEB) compounds are separated from the m-BDBEB using a thin film evaporator. ...
1989-09-25
Pressure-induced structural transitions in multi-walled carbon nanotubes
British Library Electronic Table of Contents (United Kingdom)
We demonstrate a novel cross-sectional deformation, called the radial corrugation, of multi-walled carbon nanotubes (MWNTs) under hydrostatic pressure. Theoretical analyses based on the continuum elastic approximation have revealed that MWNTs consisting of more than ten concentric walls undergo elastic deformations at critical pressure Formula Not Shown , above which the circular shape of the cross-section becomes radially corrugated. Various corrugation modes have been observed by tuning the innermost tube diameter and the number of constituent walls, which is a direct consequence of the core-shell structure of MWNTs. Cross-sectional views of MWNT under high hydrostatic pressure: elliptic deformation with the mode index n = 2 (left), and radial corrugations with n = 5 (center), and n = 6 ...
2009-01-01
Optimization of Hydrogen Consumption in Hydrogen Masers
... Hydro- gen gas is fed through a temperature- controlled Pd-Ag leak 161 into a cylindrical double-walled Pyrex bulb, 15 cm long and 1.9 cm in ...
1990-08-06
Neural Tissues from the Implanted Stem Cells
International Science & Technology Center (ISTC)
Morphological, Electrophysiological and Behavioral Investigations of the Nervous Tissue Developed from the Embryonic Matrix Zone Cells of the Dorsolateral Walls of Lateral Ventricles, Implanted into the Lesioned Regions of the Adult Rat's Brain
Mechanical jacks meant to support the movable shielding wall (Proton Room side) of the SC
This mechanical version was soon after changed into a hydraulic jack one (the reason being a number of serious constructional defects).
1955-01-01
Magnetohydrodynamic structure of a plasmoid in fast ... - NASA
We set a symmetric boundary at x=200 and a conducting wall at z=150. The domain of 0200. 0150 is resolved by 60004500 grid cells. Harris sheet ...
... 2.2.1 Polymerization of DVB Under Pressure DVB was polymerized at 300*C in thin-walled Pd-Ag capsules at pressures up to 60,000 psi. ...
1972-07-27
Fractional domain walls from on-site softening in dipolar bosons
We study dipolar bosons in a 1D optical lattice and identify a region in parameter space---strong coupling but relatively weak on-site repulsion---hosting a series of stable CDW states whose low-energy excitations, built from "fractional domain walls", are remarkably similar to those of non-abelian fractional quantum Hall states. Here, a conventional domain wall between translated CDW's may split by inserting strings of degenerate, but inequivalent, CDW states. Outside these insulating regions, we find numerous supersolids as well as a superfluid regime. The mentioned phases should be accessible experimentally, and in particular, the fractional domain walls can be created in the ground state using single-site addressing, i.e. by locally changing the chemical potential.
2011-01-01
FINAL REPORT CONTINUOUS SCANNING METEOROLOGICAL CAMERA SYSTEM FOR ...
was deemed adequate and a cooling system designed utilizing the Melcor CP2-15- 10B thermoelectric module. Wall temperature achieved with this system was - 36 ...
Elastodynamics of vehicles and crash simulation
Energy Technology Data Exchange (ETDEWEB)
Accidents of free-rolling cars against walls with friction are special cases of the general problem of the dynamic behavior (elastic or plastic) of car motion. Using particle modeling of the car body it is shown that large rotations, contact friction and plastic deformations can be computed. Because of the limitations of FEM it is necessary to model the car as a system of mass points connected by central force systems which are non-linear. The wall is formulated as a rigid body producing constraints for the contacting particles, while the contact force is given by the defined force system. Every contacting particle produces a plastic impact on the wall. The friction force is proportional to the contact force and lies in the direction of the sliding velocity on the wall. Time integration is carried out using a second order Gear method. ((orig.))
1994-09-30
DESIGN OF A CONVECTIVE COOLING SYSTEM FOR A MACH 6 - NASA ...
Figure 23 presented detailed layout of the cooling system designed for the Mach 6 hypersonic- transport. The distribution system consisted of thin-wall ...
Approximate solutions to the Stefan problem with internal heat generation
Energy Technology Data Exchange (ETDEWEB)
Using a quasi-static approach valid for Stefan numbers less than one, we derive approximate equations governing the movement of a phase change front for materials which generate internal heat. These models are applied for both constant surface temperature and constant surface heat flux boundary conditions, in cylindrical, spherical, plane wall and semi-infinite geometries. Exact solutions with the constant surface temperature condition are obtained for the steady-state solidification thickness using the cylinder, sphere, and plane wall geometries which show that the thickness depends on the inverse square root of the internal heat generation. Under constant surface heat flux conditions, closed form equations can be obtained for the three geometries. In the case of the semi-infinite wall, we show that for constant temperature and constant heat flux out of the wall conditions, the solidification layer ...
2008-05-15
Analysis of Rough Wall Turbulent Heating with Application to ...
... roughness. Since T u'v' and q v'"F the heat transfer augmentation is the square root of the skin friction augmentation: - 1/2 (( St - ,Cf 0 ...
1979-01-01
Protein isolated from hen egg-white and functions as a bacteriostatic enzyme by degrading bacterial cell walls. First enzyme ever characterized by protein ...
The two-dimensional Stefan problem with slightly varying heat flux
The authors solve the two-dimensional stefan problem of solidification in a half-space, where the heat flux at the wall is a slightly varying function of positioning along the wall, by means of a large Stefan number approximation (which turns out to be equivalent to a small time solution), and then by means of the Heat Balance Integral Method, which is valid for all time, and which agrees with the large Stefan number solution for small times. A representative solution is given for a particular form of the heat flux perturbation.
1995-09-01
TRANSMUTATIONS IN SiC IRRADIATED IN ARIES-IV FIRST WALL
The change in concentrations of elements due to transmutations resulting from neutron irradiation in the first wall of the ARIES-IV conceptual fusion energy device were determined as a function of neutron dose. SiC burns out at a rate of about 0.5% per effective full power year. The largest impurity concentration is that of He, but several other elements burn in at rates of hundreds of appm/efpy.
2001-04-01
... The composite ground floor is suitable for support to all types of wall construction and can be used equally well on strip footings or mini-pile foundations . The light steel edge beams provide the accurate template required for internal timber or light steel wall frames to minimise fitting time and eliminate rework. The floated slab surface will accept floor finishes directly and thermal insulation can be easily fitted beneath ...
Solar collectors with tubes partially filled with porous substrates
Energy Technology Data Exchange (ETDEWEB)
In this work, the thermal performance of a conventional collector is improved by inserting porous substrates at the inner walls of the collector tubes. The porous substrates improve the convective heat transfer coefficient between the tube wall and the fluid. This improvement is investigated numerically and its effects on the efficiency and the useful gain of the collector are evaluated. It is found that inserting the porous substrate may raise the collector efficiency considerably, especially at high values of the overall heat loss coefficient.
1999-02-01
Polymeric wall sealant test for radon control in a uranium mine
International Nuclear Information System (INIS)
The effectiveness of an acrylic latex wall sealant in limiting the escape of radon from rock in underground mines is the subject of this paper. Application of the latex as a two-coat system over a fillter coat of gunite produced a reduction of radon concentration from an initial level of 80 to 100 pCi/L to a final average of 25 to 30 pCi/L under similar conditions.
...direct-injection systems Atomisation from hole-type nozzles (gasoline and diesel) under cavitating flow conditions Spray-wall interaction in gasoline direct injection engines Spray-wall interaction in direct-injection diesel engines Evaporation of multi-component fuels Cavitation in diesel injectors Nozzle flow, air motion, spray development and combustion in marine diesel engines ...
Free convection heat and mass transfer to steady flow in a semi-infinite vertical porous medium
Analytical solutions are derived for a flow in a semi-infinite vertical porous medium with heat and mass transfer. When the temperature and mass concentration are uniform a constant pressure is possible and sustains a fully developed flow. Thereafter there is a small perturbation on the wall temperature and concentration and the subsequent two-dimensional problem is tackled for a large Prandtl number, free convection parameters and small Reynolds number. The heat transfer rate at the wall is discussed quantitatively.
1988-02-01
Fouling Study of Silicon Oxide Pores Exposed to Tap Water
Energy Technology Data Exchange (ETDEWEB)
We report on the fouling of Focused Ion Beam (FIB)-fabricated silicon oxide nanopores after exposure to tap water for two weeks. Pore clogging was monitored by Scanning Electron Microscopy (SEM) on both bare silicon oxide and chemically functionalized nanopores. While fouling occurred on hydrophilic silicon oxide pore walls, the hydrophobic nature of alkane chains prevented clogging on the chemically functionalized pore walls. These results have implications for nanopore sensing platform design.
2007-07-12
Fabrication of nanoscale Ti honeycombs by focused ion beam
Energy Technology Data Exchange (ETDEWEB)
Ti honeycombs with the side of 800 and 400 nm were fabricated by focused ion beam (FIB), though the surfaces of the bottom and wall of the Ti honeycombs were rough, as compared with the surfaces of the bottom and wall of the Si honeycomb. It is demonstrated that the nanoscale Ti components can be fabricated in a short time by FIB.
2003-03-15
Fabrication and testing of small scale mock-ups of ITER shielding blanket
International Nuclear Information System (INIS)
Small scale mock-ups of the primary first wall, the baffle first wall, the shield block and a partial model for the edge of the primary first wall module were designed and fabricated incorporating most of the key design features of the ITER shielding blanket. All mock-ups featured the DSCu heat sink, the built-in SS coolant tubes within the heat sink and the SS shield block. CFC tiles was used as the protection armor for the baffle first wall mock-up. The small scale shield block mock-up, integrated with the first wall, was designed to have a poloidal curvature specified in the ITER design. Fabrication routes of mock-ups were decided based on the single step solid HIP of DSCu/DSCu, DSCu/SS and SS/SS reflecting the results of previous joining techniques development and testing. For attaching the CFC tiles onto DSCu heat sink in the fabrication of the baffle first ...
1998-09-01
Doublet III limiter/armor update
Energy Technology Data Exchange (ETDEWEB)
The Doublet III device is operating with an extensive system of plasma limiters and wall protective armor. Operations with up to 8MW of neutral beam power and 1.5MA plasma current are planned. Design and operational performance of the following systems are discussed: 1. Water-cooled graphite moveable limiter. 2. Water-cooled graphite fixed limiter and neutral beam wall armor. 3. Radiatively cooled Inconel divertor plates.
1983-12-01
Energy Technology Data Exchange (ETDEWEB)
A side terminal battery is described comprising: a casing having a side wall made from a moldable material; and a plug formed of relatively deformable, electrically conductive, corrosion resistant material molded into the side wall to form a seal between the interior and exterior of the casing and including a battery terminal insert embedded therein so as to be exposed at the exterior of the casing and isolated, by the plug, from the interior of the casing.
1988-03-08
Simulation of electromechanical and thermomechanical loads on first wall mock-ups
International Nuclear Information System (INIS)
During the operation of a tokamak, the first wall elements suffer very high heat fluxes. Heat is removed by internal cooling by means of water, helium or fluid metal. The resulting inhomogeneous temperature field cause internal stresses which, due to the pulsed operation are of cyclic nature. Additional mechanical stresses in the first wall may be caused by disruptions or vertical plasma movements. During theses events high currents are induced in the metallic part of the first wall which by their interaction with the magnetic field of the tokamak lead to mechanical forces. These electromechanical stresses may lie beyond the yield stress of the structural material. From the interaction of thermal and mechanical forces, a complex stress state is achieved which under certain circumstances may lead to premature failure and/or to progressive plastic deformations (ratcheting). In order to study the boundary conditions for the ...
Powder collection apparatus/method
Energy Technology Data Exchange (ETDEWEB)
Device for separating and collecting ultrafine atomized powder from the gas stream of a gas atomizing apparatus comprises a housing having an interior wall oriented at an angle relative to horizontal so as to form a downwardly converging, conical expansion chamber, an inlet conduit communicated to the expansion chamber proximate an upper region thereof for receiving the gas stream, and an outlet proximate a lower region of the expansion chamber. The inlet conduit is oriented at a compound inclined angle (with respect to horizontal) selected to promote separation and collection of powder from the gas stream in the expansion chamber. The compound angle comprises a first entrance angle that is greater than the angle of repose of the powder on the housing interior wall such that any powder accumulation in the inlet conduit tends to flow down the wall toward the outlet. The second angle is selected generally equal to the angle ...
1994-01-11
Evaluation of pipe whip impacts on neighboring piping and walls of the Ignalina nuclear power plant.
Energy Technology Data Exchange (ETDEWEB)
Presented in this paper is the transient analysis of a Group Distribution Header (GDH) following a guillotine break at the end of the header. The GDH is the most important component of reactor safety in case of accidents. Emergency Core Cooling System (ECCS) piping is connected to the GDH piping such that, during an accident, coolant passes from the GDH into the ECCS. The GDH that is propelled into motion after a guillotine break can impact neighboring GDH pipes or the nearest wall of the compartment. Therefore, two cases are investigated: GDH impact on an adjacent GDH and its attached piping; and GDH impact on an adjacent reinforced concrete wall. A whipping RBMK-1500 GDH along with neighboring concrete walls and pipelines is modeled using finite elements. The finite element code NEPTUNE used in this study enables a dynamic pipe whip structural analysis that accommodates large displacements and nonlinear material ...
2002-02-26
International Nuclear Information System (INIS)
Research highlights: #-># Morphological and chemical characterization at atomic scale of porous alumina layers anodised in ordered regimes. #-># Characterization based on the use of FEG-SEM, STEM-HAADF, STEM-EELS and STEM-X-EDS. #-># Nanoscale distribution of P-, C- and S-bearing species in the pore wall. - Abstract: Ordered porous alumina layers prepared by two-step anodising in phosphoric, oxalic and sulphuric acids have been characterized at sub-nanometer scale using electron microscopy techniques. FEG-SEM and STEM-HAADF images allowed estimating the pore size, cell wall and pore wall thicknesses of the layers. Nanoanalytical characterization has been performed by STEM-EELS and STEM-X-EDS. Detailed features of the spatial distribution of anions in the pore wall of the films have been obtained. Maximum concentration of P-species occurs, approximately, at the middle of the pore ...
2010-11-01
Thermal performance of phase change wallboard for residential cooling application
Energy Technology Data Exchange (ETDEWEB)
Cooling of residential California buildings contributes significantly to electrical consumption and peak power demand mainly due to very poor load factors in milder climates. Thermal mass can be utilized to reduce the peak-power demand, downsize the cooling systems, and/or switch to low-energy cooling sources. Large thermal storage devices have been used in the past to overcome the shortcomings of alternative cooling sources, or to avoid high demand charges. The manufacturing of phase change material (PCM) implemented in gypsum board, plaster or other wall-covering material, would permit the thermal storage to become part of the building structure. PCMs have two important advantages as storage media: they can offer an order-of-magnitude increase in thermal storage capacity, and their discharge is almost isothermal. This allows the storage of high amounts of energy without significantly changing the temperature of the room envelope. As heat ...
1997-04-01
Energy Technology Data Exchange (ETDEWEB)
The Pequop Mountains (PM), Wood Hills (WH) and East Humboldt Range (EHR), NE Nevada, provide evidence that the hinterland of the Sevier thrust belt experienced large-magnitude Mesozoic shortening ([>=]55 km) and crustal thickening ([>=] 30 km). These ranges expose a structurally continuous crustal cross section of unmetamorphosed to high pressure upper amphibolite facies Triassic to Precambrian miogeoclinal strata. This sequence lies structurally beneath unmetamorphosed extensional klippen that omit metamorphic grade and crustal section, but also repeat stratigraphic units. Because they repeat stratigraphic units, the underlying miogeoclinal section, or footwall, must have once lain beneath a thrust fault (herein named the Windermere thrust). The footwall of the Windermere thrust was exhumed by two generations of top-to-the-W-NW low-angle normal faults that are distinguished by whether they are depositionally overlapped by Eocene volcanic rocks or if they cut the volcanic rocks ...
1993-04-01
Energy Technology Data Exchange (ETDEWEB)
The US DOE manages the safe storage of approximately 650,000 tons of depleted uranium hexafluoride remaining from the Cold War. This slightly radioactive, but chemically active, material is contained in more than 46,000 steel storage cylinders that are located at Oak Ridge, Tennessee; Paducah, Kentucky; and Portsmouth, Ohio. Some of the cylinders are more than 40 years old, and approximately 17,500 are considered problem cylinders because their physical integrity is questionable. These cylinders require an annual visual inspection. The remainder of the 46,000-plus cylinders must be visually inspected every four years. Currently, the cylinder inspection program is extremely labor intensive. Because these inspections are accomplished visually, they may not be effective in the early detection of leaking cylinders. The inspection program requires approximately 12--14 full-time-equivalent (FTE) employees. At the cost of approximately $125K per FTE, this translates to $1,500K per annum just ...
1997-02-01
Options for passive containment cooling in next-generation nuclear plant designs
International Nuclear Information System (INIS)
A design for passive cooling of large containment structures has progressed sufficiently to move forward into the detailed design stage necessary for plant construction. For such application, a safety analysis report has already been submitted to the US Nuclear Regulatory Commission. The design considers an annulus between the inner steel containment vessel and outer, thick-walled concrete shield building with chimney-like natural convection cooling driven only by a density gradient relative to the atmosphere. Air within the annulus is heated as internal containment temperature rises and heat is transferred through the steel containment shell. The resulting air density gradient between the annulus and the environment causes the heated air to rise, producing a natural convection flow through inlets in the shield building, past the steel shell, and out an exit chimney. Several options for enhancing passive heat removal of large containment buildings have been ...
1993-11-01
International Nuclear Information System (INIS)
The mechanism of lead transport is presented, and especially the particular similarities or dissimilarities between lead and calcium in this process. The absorption of these metals was determined cockerels, raised on a commercial diet or on a specified diet, using in vivo ligated loop procedure. The dose administered into the loop contained 0.5 #mu#Ci "2"0"3Pb (and/or 0.1 #mu#Ci "4"7Ca), and 0.01 mM lead acetate (and/or mM CaCl_2) in 0.5 ml 0.15 M NaCl,pH 6.5. It was shown that lead is rapidly taken up by the mucosal tissue, and slowly transferred into the body, whereas less calcium is retained by the tissue and the transfer of calcium is many times as effective as that for lead. They appear to respond in a similar manner to a low calcium intake and vitamin D treatment. Increasing luminal stable lead concentration significantly reduced the percentage of radiolead significantly reduced the percentage of radiolead absorbed, but did not affect the absorption of ...
Investigation of corrosion experienced in a spray calciner/ceramic melter vitrification system
Energy Technology Data Exchange (ETDEWEB)
After periodic testing of a large-scale spray calciner/ceramic melter vitrification system over a 2-yr period, sufficient corrosion was noted on various parts of the vitrification system to warrant its disassembly and inspection. A majority of the 316 SS sintered metal filters on the spray calciner were damaged by chemical corrosion and/or high temperature oxidation. Inconel-601 portions of the melter lid were attacked by chlorides and sulfates which volatilized from the molten glass. The refractory blocks, making up the walls of the melter, were attacked by the waste glass. This attack was occurring when operating temperatures were >1200/sup 0/C. The melter floor was protected by a sludge layer and showed no corrosion. Corrosion to the Inconel-690 electrodes was minimal, and no corrosion was noted in the offgas treatment system downstream of the sintered metal filters. It is believed that most of the melter corrosion occurred during one specific operating ...
1980-08-01
Energy Technology Data Exchange (ETDEWEB)
The article deals with the problem of a humidity addition to thermal conductivity, diffusion and latent heat effects in heat transfer through building components. It shows with examples humidity effects for exterior walls with core insulation, with composite insulation system as well as for insulated roof membrane assemblies. From these it can be summarized that - sorption humidity is for today`s construction conditions (good thermal insulation and humidity protection) a suitable reference quantity for the determination of practice-oriented, substance-specific and physically correct humidity additions to the thermal conductivity of hygroscopic components; - diffusion and latent heat effects are in case of good rain imperviousness and low water absorbing capacity of the exterior component layers of secondary importance for transmission heat losses; - an increase in insulating layer thickness in order to improve the thermal insulation is possible ...
1994-12-31
Energy Technology Data Exchange (ETDEWEB)
Spin-polarized liquid helium-3 is prepared by laser optical pumping in low magnetic field and at room temperature, prior to fast liquefaction of the polarized sample. The use of a new helium-3 cryostat enabled us to obtain liquid helium-3 with polarization rates up to 25 % at well-stabilized temperatures (around 0.5 K). We could thereby study the effect of nuclear polarization on liquid-vapour equilibrium, and particularly on the saturated vapour pressure. Very sensitive capacitive gauges were developed. We estimated (to first order in M{sup 2}) the expected effects when the polarization M is suddenly destroyed. These effects were experimentally observed in helium-3/helium-4 mixtures, in pure helium-3, only a transient increase in pressure has been recorded. We then describe in a third part a preliminary experiment which aimed at determining the longitudinal relaxation time T1 in mixtures. Relaxation on the walls is efficiently reduced by a ...
1999-07-15
Compatibility analysis of DUPIC fuel (part 3) - radiation physics analysis
International Nuclear Information System (INIS)
As a part of the compatibility analysis of DUPIC fuel in CANDU reactors, the radiation physics calculations have been performed for the CANDU primary shielding system, thermal shield, radiation damage, transportation cask and storage. At first, the primary shield system was assessed for the DUPIC fuel core, which has shown that the dose rates and heat deposition rates through the primary shield of the DUPIC fuel core are not much different from those of natural uranium core because the power levels on the core periphery are similar for both cores. Secondly, the radiation effects on the critical components and the themal shields were assessed when the DUPIC fuel is loaded in CANDU reactors. Compared with the displacement per atom (DPA) of the critical component for natural uranium core, that for the DUPIC fuel core was increased by -30% for the innermost groove and the weld points and by -10% for the corner of the calandria subshells and annular plates in the ...
2009-07-01
Acid mine drainage and its impact in the Black Creek watershed, Virginia
International Nuclear Information System (INIS)
A one-year study was conducted to determine the impacts of acid min drainage (AMD) on the Black Creek watershed in Wise County, Virginia. Water quality, metal content of sediment and water column, soil pH, macroinvertebrate assemblages, habitat assessment and toxicity testing were used to assess the impact in the watershed. A total of 22 sites in the creek and surrounding watershed were actively monitored. This included six primary sources of AMD. Conductivity measurements > 1,000 microhmos/cm were found at eight sites and pH was consistently below 6.0 at seven. Of six metals analyzed, magnesium was highest in the water column, ranging from 16.5 mg/L to 130 mg/L. Aluminum and iron were both elevated in the sediment with iron concentrations as high as 176,000 mg/kg. An increase in sediment metal concentrations was noted when progressing downstream in the creek. Of nine high wall and spoils areas sampled, soil pH was acidic in eight sites, ...
1996-11-17
Cellular Sources of Transforming Growth Factor-? Isoforms in Early and Chronic Radiation Enteropathy
The three mammalian transforming growth factor (TGF)-? isoforms (TGF-?1, TGF-?2, and TGF-?3) differ in their putative roles in radiation-induced fibrosis in intestine and other organs. Furthermore, tissue specificity of TGF-? action may result from temporal or spatial changes in production and/or activation. The present study examined shifts in the cell types expressing TGF-? mRNA relative to TGF-? immunoreactivity and histopathological injury during radiation enteropathy development. A 4-cm loop of rat small intestine was locally exposed to 0, 12, or 21-Gy single doses of x-irradiation. Sham-irradiated and irradiated intestine were procured 2 and 26 weeks after irradiation. Cells expressing the TGF-?1, TGF-?2, or TGF-?3 transcripts were identified by in situ hybridization with digoxigenin-labeled riboprobes. Intestinal wall TGF-? immunoreactivity was measured using computerized image analysis, and structural radiation injury was assessed by quantitative ...
1998-11-01
Review of JT-60U experimental results from February to October, 1999
International Nuclear Information System (INIS)
In 1999, the plasma parameters of reversed shear (RS) plasmas had been extended in 1) DT-equivalent fusion power gain Q_D_T"e"q - 0.5 (n_D(0)#tau#_ET_i(0) - 4x10"2"0 m"-"3#centre dot#keV#centre dot#s) for 0.8 s and 2) full non-inductive current drive with 80% of the bootstrap current fraction. Physics of the internal transport barriers (ITBs) in RS plasmas, including the energy transport and the formation of ITB, were extensively studied. A nearly full current drive (92% non-inductively) was obtained with negative ion based neutral beam (NNB) injection (360 keV, 3.4 MW) in a high #beta#_p H-mode plasma (I_p=1.5 MA, B_T=3.7 T, q_9_5=4.2) with high plasma performance (#beta#_N=2.4 and H_8_9=2.56). Rise in the central electron temperature (T_e - 9 keV) resulted in the current drive efficiency #eta#_C_D of NNB reached 1.3x10"1"9 A/W/m"2, the highest for the neutral beam current drive. As for the H-mode plasmas, decrease in the pedestal ion temperature due to strong gas was found cause ...
1994-06-01
A study of flow boiling phenomena using real time neutron radiography
International Nuclear Information System (INIS)
The operation and safety of both fossil-fuel and nuclear power stations depend on adequate cooling of the thermal source involved. This is usually accomplished using liquid coolants that are forced through the high temperature regions by a pumping system; this fluid then transports the thermal energy to another section of the power station. However, fluids that undergo boiling during this process create vapor that can be detrimental, and influence safe operation of other system components. The behavior of this vapor, or void, as it is generated and transported through the system is critical in predicting the operational and safety performance. This study uses two advanced penetrating radiation techniques, Real Time Neutron Radiography (RTNR), and High Speed X-Ray Tomography (HS-XCT), to examine void generation and transport behavior in a flow boiling system. The geometries studied were tube side flow boiling in a cylindrical configuration, and a similar flow channel with an internal ...
1346-01-01
International Nuclear Information System (INIS)
This paper introduces the JNM Special Issue on the development of a first wall for the reaction chamber in a laser fusion power plant. In this approach to fusion energy a spherical target is injected into a large chamber and heated to fusion burn by an array of lasers. The target emissions are absorbed by the wall and encapsulating blanket, and the resulting heat converted into electricity. The bulk of the energy deposited in the first wall is in the form of X-rays (1.0-100 keV) and ions (0.1-4 MeV). In order to have a practical power plant, the first wall must be resistant to these emissions and suffer virtually no erosion on each shot. A wall candidate based on tungsten armor bonded to a low activation ferritic steel substrate has been chosen as the initial system to be studied. The choice was based on the vast experience with these materials in a nuclear environment and the ...
2005-12-15
WWER steam generator transients during loss of coolant accidents
International Nuclear Information System (INIS)
A nonlinear mathematical model is presented of a WWER-440 nuclear power plant horizontal steam generator. On the proposed model is based a computer program for investigating transients in steam generators during loss of coolant accidents. Processes taking place at the primary side of the steam generator are described by a set of partial differential equations while those at the secondary side of the steam generator are described by plain differential equations with the variables being complex time functions. The model takes account of the coolant as both a single- and two-phase medium, of changes in the direction of the primary coolant flow and of changes in the direction of heat transfer. Heat transfer through the wall is based on a simple model of heat transfer through a thin-walled tube and includes a correction for the heat resistance of the wall. (author).
1978-01-01
Energy Technology Data Exchange (ETDEWEB)
Based on the CFD-code FLUENT trademark, theoretical studies were conducted of the influences of incineration chamber geometry (direct, countercurrent and center flow) on the combustion process. The boundary conditions, e.g., the thermal input and the waste grate, were kept constant. Close attention was paid to the distribution of flow, spe-cies, and temperatures. In addition, the influence of a dis-placement body at the end of the combustion chamber was tested. The variation of different wall materials and the prediction of problem areas concerning corrosion, slagging, and contamination completed the studies. Close to the chamber walls, high CO-concentrations may indi-cate corrosion; particle flow may indicate where contami-nation, slagging or erosion could occur. (orig.)
2001-01-01
Energy Technology Data Exchange (ETDEWEB)
A new kind of receiver-reactor for high-temperature solar furnaces is proposed. The main body of the receiver component is an ellipsoid of revolution with specularly reflecting inner walls. The reactor component, a crucible, is placed at one focal point and the aperture at the other. With this arrangement, substantially all of the incident radiation from the concentrator should reach the reactor directly or after one reflection from the cavity walls. An analysis of the radiative exchange among the surfaces is presented. The analysis provides a tool for a parametric study and optimization of the design. It is found that, in contrast to that of conventional well-insulated cavity receivers, its collection efficiency is not very sensitive to the size of its aperture.
1987-10-27
Post-CHF heat transfer with water and refrigerants
Energy Technology Data Exchange (ETDEWEB)
Heat transfer experiments were performed in the post-CHF two-phase flow regime in a vertical tube. The tube inside diameter was 7.75 mm, and the boiling fluid was R-113. The experiments were performed at steady state by means of liquid heating of the test tube. Wall superheats were maintained below 70 C for heat exchanger/steam generator application. The mass flux range of the data was 379-816 kg m{sup -2} s{sup -1}. The use of R-113 significantly extended the property range of the existing low wall-superheat data base. Experimental data are presented in tabular as well as graphical form, and the results were used with low wall-superheat data from other fluids to add generality to a predictive heat transfer correlation. (orig.)
1996-06-01
In this paper, four different types of pulsed eddy current (PEC) probe are designed and their performance of detecting wall thickness reduction is compared. By using the backward difference method in time and the finite element method in space, PEC signals from various thickness and materials are numerically calculated and three features of the signal are selected. Since PEC signals and features are obtained by various types and sizes of probe, the comparison is made through the normalized features which reflect the sensitivity of the feature to thickness reduction. The normalized features indicate that the shielded reflection probe provides the best sensitivity to wall thickness reduction for all three signal features. Results show that the best sensitivity to thickness reduction is achieved by the peak value, but also suggest that the time to peak can be a good candidate because of its linear relationship with the thickness variation.
2010-02-01
Numerical simulation of slagging films in the Aachen pressurized coal combustion facility
Energy Technology Data Exchange (ETDEWEB)
Combined gas and steam turbine processes based on direct coal firing show a high thermal efficiency. At RWTH Aachen, University of Technology, an experimental test furnace has been built to investigate the pressurized pulverized coal combustion (PPCC). The PPCC-facility has been constructed as a slag tap furnace. Particles hitting the walls at temperatures above the melting point cause slagging depositions and create a film flowing down the reactor walls. As a part of the PPCC-program different mathematical models have been developed and implemented into the CFD-code FLUENT to predict the behavior of slag films at the furnace walls. Numerical strategies and the mathematical models used are described in detail. 12 refs., 9 figs.
2001-07-01
Energy Technology Data Exchange (ETDEWEB)
The evaluation of calculated values determined by means of the equations given in the TRD 300/301 standard resulted in two nomographs by which it is possible to find the theoretical wall thickness of cylinder shells without cutouts and branches as well as cylinder shells with an inclined or vertical single branch without additional thickening. The equations for the calculation of cylinder shells with an inclined single branch according to TRD 301 having only an iterative solution, the nomographs will be a considerable help for the engineering work. The determination of the theoretical wall-thickness from the nomographs is demonstrated by means of examples.
1981-06-01
Natural convection cooling of the IFMIF target and test cell
International Nuclear Information System (INIS)
The present work summarizes efforts on the simulation of natural convection cooling within the IFMIF target and test cell. The simulations have been performed with the STAR-CD code using the k-#omega# high-Reynolds number turbulence model. A dedicated thermohydraulic model has been devised including Lithium loop components. Nuclear heat production has been calculated by the Monte-Carlo code McDeLicious for different parts of the target and test cell walls and was used as input for the STAR-CD simulations. Helium atmospheres at several pressures from 0.1 to 10"-"5 MPa have been investigated. In order to limit the maximum temperature of the concrete walls to 80 deg. C it was necessary to add thermal insulation layers to the hot Lithium loop surfaces and a conceptual system of two cooling layers in different depths of the concrete walls.
2007-10-01
Energy Technology Data Exchange (ETDEWEB)
Lateral plume dispersion in deep river valleys during neutral and stable lapse rate conditions can be exceptionally high due to the intense horizontal turbulence generated by prominent variations in the width, orientation and surface roughness of the valley walls. Use of the standard Gaussian dispersion equation to represent this enhanced lateral plume spread in a narrow valley may be inappropriate since consideration should also be given to the restriction of the horizontal plume spread due to impingement against the valley walls. The basic concept employed in the modification of the Gaussian dispersion equation was to assume that multiple eddy reflections occur between the valley walls in a manner similar to the vertical eddy reflections between the ground plane and an inversion layer aloft. The expressions are developed, but no attempt has been made to validate them with actual measured field data. 4 references, 3 ...
1986-02-01
International Nuclear Information System (INIS)
In the frame of the Primary Wall Module prototype manufacturing for ITER, a consistent R and D phase was conducted in order to identify the industrial allowable tolerances and manufacturing problems which would occur when joining pieces by HIPping process during the PW module manufacturing. The purpose of this development was to give as industrial as possible manufacturing routes for joining together large Stainless Steel or DS-Copper pieces with Stainless Steel tubes and for bonding Beryllium tiles onto a curved component surface. The study concerned surface preparations, allowable gaps and joint geometry, Beryllium tile geometry, Titanium interlayer thickness, etc. This R and D phase also allowed the development and validation of different ultrasonic inspection tools needed for plate-plate, tube-plate, edge to edge plate bonding.
2001-10-01
Local heat transfer augmentation in channels with two opposite ribbed surfaces
The local heat transfer coefficient distribution of a square channel with two opposite ribbed walls was determined. The square channel was connected to a sudden contraction entrance in order to simulate the inlet condition of the turbine blade cooling passages. The test channel was heated by thin stainless steel foils with a thickness of 0.000025 m, and instrumented with 180 thermocouples. The brass ribs of a square cross-section were glued periodically, in line, onto the top and bottom walls of the foil-heated channel in patterns to achieve the desired spacing and angle-of-attack. The local heat transfer coefficients on the smooth side and the ribbed side walls, at the channel entrance and the downstream regions, were measured for eight rib configurations and three Reynolds numbers (Re = 10,000, 30,000, and 60,000).
1986-01-01
General flow and thermal boundary conditions in indoor air flow simulation
Energy Technology Data Exchange (ETDEWEB)
The concepts of general flow and thermal boundary conditions are introduced to treat the interaction between indoor and outdoor thermal environments in computational fluid dynamics (CFD) simulations. The results from a multi-zone model are used to supply the general flow boundary conditions. The energy balance equation at wall-air interfaces is used to supply the general thermal boundary conditions. An example calculation in a 13-room building shows that infiltration influences indoor air flow patterns considerably. The air flow in a room ventilated by displacement is measured and simulated. Two surface coatings are considered, i.e. black walls and aluminum walls. Implementation of these two boundary conditions is essential in predicting air flow patterns, air quality, and thermal comfort in a real building. (author)
1994-12-31
Energy Technology Data Exchange (ETDEWEB)
In order to develop the filler metal for Hastelloy alloy XR structure with thick wall, the weldability and high temperature strength properties of Hastelloy alloy XR weldment were investigated using the filler metals, which were alloy-designed on the basis of multiple regression analysis. The former was examined through the chemical analysis in the deposited metal, bend test, FISCO cracking test, optical microscopy and hardness measurement. The latter was investigated by means of tensile and creep test. It was found from these results that the crack susceptibility in the weldment was apparent to be lowered without degrading the high temperature strength properties. Therefore, it is concluded that these filler metals possess excellent performance as the filler metal for Hastelloy alloy XR structure with thick wall. (author).
1991-11-01
Dosimetry of iodine-123 iomazenil in humans
International Nuclear Information System (INIS)
The distribution of the central benzodiazepine receptor specific ligand iodine-123 iomazenil was investigated in seven human adults from whole-body scans, blood samples and urine collected up to 24 h after injection. Using 12 source organs, the MIRD method was applied to calculate the absorbed radiation dose of the radioligand in various organs. The urinary bladder wall (0.15 mGy/MBq), lower large intestinal wall (0.071 mGy/MBq) testes (0.044 mGy/MBq) and upper large intestined wall (0.038 mGy/MBq) received the highest absorbed doses. The average effective dose equivalent of "1"2"3I-IBZM for adults was estimated to be 0.033 mSv/MBq. (orig.).
Energy Technology Data Exchange (ETDEWEB)
A dielectric-wall linear accelerator is improved by a high-voltage, fast rise-time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators. A high voltage is placed between the electrodes sufficient to stress the voltage breakdown of the insulator on command. A light trigger, such as a laser, is focused along at least one line along the edge surface of the laminated alternating layers of isolated conductors and insulators extending between the electrodes. The laser is energized to initiate a surface breakdown by a fluence of photons, thus causing the electrical switch to close very promptly. Such insulators and lasers are incorporated in a dielectric wall linear accelerator with Blumlein modules, and phasing is controlled by adjusting the length of fiber optic cables that carry the laser light to the insulator surface.
1998-01-01
Energy Technology Data Exchange (ETDEWEB)
A dielectric-wall linear accelerator is improved by a high-voltage, fast rise-time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators. A high voltage is placed between the electrodes sufficient to stress the voltage breakdown of the insulator on command. A light trigger, such as a laser, is focused along at least one line along the edge surface of the laminated alternating layers of isolated conductors and insulators extending between the electrodes. The laser is energized to initiate a surface breakdown by a fluence of photons, thus causing the electrical switch to close very promptly. Such insulators and lasers are incorporated in a dielectric wall linear accelerator with Blumlein modules, and phasing is controlled by adjusting the length of fiber optic cables that carry the laser light to the insulator surface. 12 figs.
1998-10-13
Energy Technology Data Exchange (ETDEWEB)
The wavenumber-frequency spectral densities of turbulent wall pressure fluctuations are investigated over a rigid flat plate. Nonlinear Reynolds stress terms of the inhomogeneous Orr-Sommerfeld equation are regarded as a known forcing function. The forcing function is modeled after Bark{close_quote}s hydrodynamic bursting formulation. The inhomogeneous Orr-Sommerfeld equation is solved by the method of Eckhaus in terms of discrete homogeneous solutions. The method of Eckhaus is then extended and proved for the continuous Orr-Sommerfeld eigenfunctions. Turbulent wall pressure fluctuations in terms of wavenumber-frequency spectral densities are numerically computed and compared to the experimental results of Martin as well as to his transformation of Blake{close_quote}s data fitted to a modified Corcos model. The wavenumber-frequency spectral densities numerically computed from the discrete eigenfunctions compared well with Martin{close_quote}s ...
1996-06-01
The supply of small scale mock-ups of the primary wall module concepts for ITER
International Nuclear Information System (INIS)
The present design of Blanket Shield and Primary Wall for ITER envisages construction of the wall with a water cooled, stainless steel outer layer and a water cooled, copper liner on the inside plasma facing surface. Protection of the inner copper surface with an armour layer is necessary to cope with plasma to wall interaction. There are a number of armour materials under consideration, for this project beryllium was used. The scope of work was to produce a series of mock-ups, each consisting of a different combination of materials, which included Dispersion Strengthened Copper, Copper-Chrome-Zirconium alloy, Beryllium and Stainless Steel. Hot Isostatic Pressing (HIP) was the method used to ensure that a fully diffused bonded joint was achieved giving the necessary strength and thermal conductivity. The first five of the mock ups have been successfully completed and are being tested at the various laboratories in Europe. ...
1998-09-07
Sortases and the Art of Anchoring Proteins to the Envelopes of Gram-Positive Bacteria
UK PubMed Central (United Kingdom)
The cell wall envelopes of gram-positive bacteria represent a surface organelle that not only functions as a cytoskeletal element but also promotes interactions between bacteria and their environment....Full Text Available
2006-03-01
Role of the sar locus of Staphylococcus aureus in induction of endocarditis in rabbits.
UK PubMed Central (United Kingdom)
A regulatory locus on the Staphylococcus aureus chromosome, designated sar, is involved in the expression of cell wall proteins, some of which are potentially important in the pathogenesis of endocarditis....Full Text Available
1994-05-01
Remote environmental monitoring at No. 26 Colliery
Energy Technology Data Exchange (ETDEWEB)
The author describes the layout of the environmental monitoring scheme at Devco's No. 26 Colliery in Canada, which includes wall face ventilation, fan performance, and methane drainage monitoring. He gives details of the sensors, outstations, and the surface control room.
1982-03-01
Properties of a cell-wall-defective variant of Brucella abortus of bovine origin.
UK PubMed Central (United Kingdom)
The properties of an atypical Brucella strain isolated from lymph node tissue of a cow slaughtered as a brucellosis reactor were examined. The organism was Gram negative and highly pleomorphic, existing...Full Text Available
1980-08-01
UK PubMed Central (United Kingdom)
Mycolic acids are key cell wall components for the survival, pathogenicity, and antibiotic resistance of the human tubercle bacillus. Although it was thought that Mycobacterium tuberculosis...Full Text Available
2010-04-23
Optimizing the design of solar energy greenhouses
Energy Technology Data Exchange (ETDEWEB)
In Canada, the cost of heating is a major expense in the operation of greenhouses in the winter season, inhibiting greenhouse production in winter months in most part of the country. Alternative energy sources, such as solar energy and biomass energy may offer an economically feasible heating alternative. A solar energy greenhouse technology developed in northern China for winter vegetable production has demonstrated good potential for Manitoba winter conditions. The design and performance of solar energy greenhouses depend on the geographical location. Therefore, in order to optimize the design of solar greenhouses with respect to the latitude of the location for maximum solar radiation gain, a theoretical analysis was performed that analyzed parameters such as greenhouse length and the roof slope. This paper described the methodology of the study, including a description of solar energy greenhouses; the energy of solar radiation; shading of the north roof; shading of the end ...
2006-07-01
Massive encapsulation of larval Anguillicoloides crassus in the intestinal wall of Japanese eels
UK PubMed Central (United Kingdom)
BackgroundWithin the last 25 years, after the introduction of the swimbladder nematode Anguillicoloides crassus from East-Asia to Europe, a body of work has aggregated...Full Text Available
UK PubMed Central (United Kingdom)
BackgroundGastrointestinal stromal tumors (GISTs) are mesenchymal tumors that develop in the wall of the gastrointestinal tract and their diagnosis during pregnancy or puerperium...Full Text Available
Induction of autolysis in nongrowing Escherichia coli.
UK PubMed Central (United Kingdom)
Unless relaxation of the stringent response is achieved, all nongrowing bacteria rapidly develop resistance to autolysis induced by a variety of agents, including all classes of cell wall synthesis...Full Text Available
1986-09-01
High resolution scanning electron microscopy of plasmodesmata.
Symplastic transport occurs between neighbouring plant cells through functionally and structurally dynamic channels called plasmodesmata (PD). Relatively little is known about the composition of PD or the mechanisms that facilitate molecular transport into neighbouring cells. While transmission electron microscopy (TEM) provides 2-dimensional information about the structural components of PD, 3-dimensional information is difficult to extract from ultrathin sections. This study has exploited high-resolution scanning electron microscopy (HRSEM) to reveal the 3-dimensional morphology of PD in the cell walls of algae, ferns and higher plants. Varied patterns of PD were observed in the walls, ranging from uniformly distributed individual PD to discrete clusters. Occasionally the thick walls of the giant alga Chara were fractured, revealing the surface morphology of PD within. External structures such as spokes, spirals and mesh ...
2011-05-28
Heat Transfer Augmentation in a Compact Heat Exchange Pedestal Array.
A compact heat exchanger pedestal array for augmenting heat transfer in a machine is disclosed. The compact heat exchanger pedestal array includes a wall having first and second surfaces. The first surface faces a heated flow path and the second surface p...
2004-01-01
An experimental investigation of heat transfer characteristics for various configurations of air jets impinging on the leading edge inner surface of a gas turbine blade wall is presented. Three configurations were investigated, namely a slot jet, a round ...
1970-01-01
Functional and Structural Analysis of a Key Region of the Cell Wall Inhibitor Moenomycin
UK PubMed Central (United Kingdom)
Moenomycin A (MmA) belongs to a family of natural products that inhibit peptidoglycan biosynthesis by binding to the peptidoglycan glycosyltransferases (PGTs), the enzymes that make the glycan...Full Text Available
2010-07-16
Energy-resolved electron particle and energy fluxes in positive column plasmas
Energy Technology Data Exchange (ETDEWEB)
This paper deals with electron flux densities and electron energy flux densities in positive column discharges. Recent kinetic calculations by Uhrlandt and Winkler have revealed the interesting physical phenomenon of radially inward directed energy flux densities in positive column plasmas. We have used a self-consistent positive column model, based on an accurate and highly detailed Monte Carlo code, to study this effect in more depth. The results of this study show a rather complex physical picture of electron particle and energy flux densities. Electrons with low energies usually exhibit radially outward directed particle and energy flux densities. At energies above the threshold for electronic excitation particle and energy flux densities are usually inward directed. Only close to the wall, at total energies above the wall potential energy, do these flux densities point towards the wall. The thickness of this ...
1999-11-07
UK PubMed Central (United Kingdom)
The objective of this study was to develop a specific immunological diagnostic assay for yellow disease in hyacinths, using monoclonal antibodies (MAbs). Mice were immunized with a crude cell wall preparation...Full Text Available
1999-09-01
UK PubMed Central (United Kingdom)
The curvature elastic modulus (bending stiffness) of stearoyloleoyl phosphatidylcholine (SOPC) bilayer membrane is determined from membrane tether formation experiments. R. E. Waugh and R. M. Hochmuth...Full Text Available
1989-03-01
UK PubMed Central (United Kingdom)
The dental pulp consists of loose connective tissue encased in rigid dentinal walls. Because of its topography the tissue has low interstitial compliance and limited capacity to expand during fluid...Full Text Available
2006-05-15
UK PubMed Central (United Kingdom)
In a previous study we found that nanofibrous poly(l-lactic acid) (PLLA) scaffolds mimicking collagen fibers in size were superior to solid-walled scaffolds in promoting osteoblast differentiation...Full Text Available
2009-08-01
UK PubMed Central (United Kingdom)
BackgroundWide resection with tumor-free margins is necessary in soft-tissue sarcomas to minimize local recurrence and to contribute to long-term survival. Information about treatment...Full Text Available
2011-01-01
UK PubMed Central (United Kingdom)
We used tryptophan auxotrophs of the dicot Arabidopsis thaliana (wall cress) to determine whether tryptophan has the capacity to serve as a precursor to the auxin, indole-3-acetic acid (IAA). Quantitative...Full Text Available
1993-11-01
Angiomatoid giant cellular blue nevus of vaginal wall associated with pregnancy
UK PubMed Central (United Kingdom)
BackgroundBlue nevi that arise from the Müllerian tract are rare melanocytic lesions. Several histopathologic variants of cellular blue nevi have been described. The angiomatoid...Full Text Available
Activation calculations using an expanded data base
Energy Technology Data Exchange (ETDEWEB)
Using an expanded nuclear data base, the activation of nitrogen, aluminum, iron, nickel, copper, zirconium, niobium, molybdenum, tungsten, and lead were calculated for the first wall positions of the STARFIRE and MARS conceptual fusion reactors.
1986-04-01
Energy Technology Data Exchange (ETDEWEB)
Hollow needles made of an electrically conducting material are attached by hinges in the openings of the perforated end of an insert in order to intensify heat and mass transfer. The free sections of the needles are placed outside the insert, and a wick is placed on the wall of the frame in the condensation area. The wick overlaps the inlet openings of the insert.
1980-09-23
10 - NASA Technical Reports Server
Mar 1, 2011 ... The most interesting flow characteristics observed were the occasional appearance of steady, ... pressure gradient, rather than wall divergence angle, controlled flow separation. ... Report/Patent Number: AGARD-AG-19/P9 ...
Two-phase Flow Regime Maps in Horizontal and Vertical Tubes
Energy Technology Data Exchange (ETDEWEB)
A safety analysis code to design a pressurized water reactor and to obtain the licenses including entire proprietary rights is under development in domestic R and D project. The tasks of KAERI is to develop the constitutive relations including models for defining flow regimes and flow regime related models for inter-phase friction, wall frictions, wall heat transfer, and interphase heat and mass transfer in the two-phase three-field equations. In this paper, the process will be presented for choosing the best flow regime maps which occur in gas-liquid two-phase flow in horizontal and vertical tubes.
2007-10-15
Two-phase Flow Regime Maps in Horizontal and Vertical Tubes
International Nuclear Information System (INIS)
A safety analysis code to design a pressurized water reactor and to obtain the licenses including entire proprietary rights is under development in domestic R and D project. The tasks of KAERI is to develop the constitutive relations including models for defining flow regimes and flow regime related models for inter-phase friction, wall frictions, wall heat transfer, and interphase heat and mass transfer in the two-phase three-field equations. In this paper, the process will be presented for choosing the best flow regime maps which occur in gas-liquid two-phase flow in horizontal and vertical tubes.
2007-10-01
Transverse Resistive Wall Wakefunction with Inductive Bypass
Charged particle beams in circular accelerators couple with their surroundings through induced electromagnetic fields. This interaction can be described by so-called coupling impedances. In the frequency domain the impedance in connection with the bunch spectrum allows for stability analysis and estimates. However, for simulation codes one usually needs the wakefunction, the equivalent of the impedance in time domain. Recently the transverse impedance of a cylindrical pipe with arbitrary surface impedance was given by L. Vos. An expression for the wakefunction of this transverse resistive wall impedance with inductive bypass is derived here.
2003-01-01
Torsion of moderately thick hollow tubes with polygonal shapes
British Library Electronic Table of Contents (United Kingdom)
A simple formulation is presented for torsion analysis of hollow tubes with polygonal shapes. Thicknesses of segments of cross section can be different. Governing equations in term of Prandtl's stress function are used to derive the formulas. The derived formulas are so simple that computations can be carried out with a pocket calculator. Several examples are presented to show the accuracy and efficiency of the formulation. The obtained results are verified by accurate finite element solutions. It will be seen that the derived formulas can be useful for analysis of thin-walled and moderately thick-walled hollow tubes.
2007-01-01
International Nuclear Information System (INIS)
Natural convection of vaporizing Deuterium at 25 K transports the heat generated in the moderator cell of the cold neutron source to a He cooled condenser. The thermohydraulics of this thermosiphon were precalculated and the results verified by experiments in a 1:1 model using D_2 as fluid. The experimental results show that the thermosiphon operates stable. The demanded liquid content of the cell as well as wall temperatures below 50 K can be ensured by a proper design of the cell outlet flow geometry. A 7 min. loss of cryogenic power results in transient temperatures of the cell wall of not more than 300 K.
1991-08-01
International Nuclear Information System (INIS)
Various remedial measures have been tried to lower radon levels in buildings in Uranium City. The methods used are source material removal, passive ventilation of crawl spaces, sub-floor ventilation, complete epoxy coating of the entire basement, sealants for floor-wall joints and cracks in basements, electrostatic precipitators, mechanical ventilation, and sealing and grouting concrete block plenums in basement walls. The type and condition of structures encountered in Uranium City as well as the relative isolation of the town indicate that mechanical ventilation is the most long-term cost-effective method.
1980-03-12
Energy Technology Data Exchange (ETDEWEB)
Twenty-seven patients with symptoms or clinical findings suggesting joint or bone disorders of the anterior chest wall (ACW) were evaluated by spiral CT with 3-dimensional (3-D) and multiplanar reconstructions. Preceding conventional ACW tomography was performed in 10 patients. ACW joint and bone changes were visualized more adequately by coronal 2-D reconstructions based on spiral CT than by conventional tomography. In addition, nonossified costal cartilages and soft tissue lesions were demonstrated. 3-D reconstructions sometimes added information, especially in patients with fracture and dislocation. (orig.).
1994-09-01
Solar energy receiver for a Stirling engine
Energy Technology Data Exchange (ETDEWEB)
A solar energy receiver is described including a separable endless wall formed of a ceramic material having defined therein a cavity of a substantially cylindrical configuration for entrapping solar flux, and an acceptance aperture adapted to admit to the cavity a concentrated beam of solar energy, said wall being characterized by at least a pair of contiguously related segments separated by lines of cleavage intercepting said aperture, at least one of the segments being supported for pivotal displacement, and a thermal responsive actuator adapted to respond to excessive temperatures within the cavity for initiating pivotal displacement of said one segment, whereby thermal flux is permitted to escape from the cavity.
1980-12-02
Numerical prediction of flow field and particle trajectory in a hard disk drive
Energy Technology Data Exchange (ETDEWEB)
A flow field and particle trajectory in a HDD (Hard Disk Drive) between two rotating disks in axisymmetric enclosures is investigated using CFD code FLUENT/UNS. The RNG k-{epsilon} model is used as a turbulent model. In this study, the flow field between two disks are symmetric, and the flow field near the enclosure is very complex. Cross stream vectors are shown both for blowing and no blowing from the hub. The larger a particle, the more fast the particle deposits at the walls. In the case of blowing from the hub, the more fast the particle deposits at the walls. (author). 9 refs., 12 figs., 1 tab.
1999-11-01
Mechanism of biodegradation of paraquat by Lipomyces starkeyi
Energy Technology Data Exchange (ETDEWEB)
The biodegradation of ring-/sup 14/C- and methyl-/sup 14/C-labeled paraquat by the soil yeast Lipomyces starkeyi was studied in vitro. It was found that the degradation of paraquat (acting as a sole source of culture nitrogen) resulted in the accumulation in the extracellular medium of radiolabeled acetic acid. The culture also evolved radiolabeled CO/sub 2/. The results suggest that the degradation of paraquat by L. starkeyi is associated with the integrity of the cell wall and that disruption or removal of the wall results in a complete loss of degradative capability. A mechanism for the degradation of paraquat by this organism is postulated.
1985-05-01
Mechanism of biodegradation of paraquat by Lipomyces starkeyi
International Nuclear Information System (INIS)
The biodegradation of ring-"1"4C- and methyl-"1"4C-labeled paraquat by the soil yeast Lipomyces starkeyi was studied in vitro. It was found that the degradation of paraquat (acting as a sole source of culture nitrogen) resulted in the accumulation in the extracellular medium of radiolabeled acetic acid. The culture also evolved radiolabeled CO_2. The results suggest that the degradation of paraquat by L. starkeyi is associated with the integrity of the cell wall and that disruption or removal of the wall results in a complete loss of degradative capability. A mechanism for the degradation of paraquat by this organism is postulated.
Low emissions compression ignited engine technology
Energy Technology Data Exchange (ETDEWEB)
A method and apparatus for operating a compression ignition engine having a cylinder wall, a piston, and a head defining a combustion chamber. The method and apparatus includes delivering fuel substantially uniformly into the combustion chamber, the fuel being dispersed throughout the combustion chamber and spaced from the cylinder wall, delivering an oxidant into the combustion chamber sufficient to support combustion at a first predetermined combustion duration, and delivering a diluent into the combustion chamber sufficient to change the first predetermined combustion duration to a second predetermined combustion duration different from the first predetermined combustion duration.
2007-04-03
Investigation of Two-Phase Flow Regime Maps for Development of Thermal-Hydraulic Analysis Codes
Energy Technology Data Exchange (ETDEWEB)
This reports is a literature survey on models and correlations for determining flow pattern that are used to simulate thermal-hydraulics in nuclear reactors. Determination of flow patterns are a basis for obtaining physical values of wall/interfacial friction, wall/interfacial heat transfer, and droplet entrainment/de-entrainment. Not only existing system codes, such as RELAP5-3D, TRAC-M, MARS, TRACE, CATHARE) but also up-to-date researches were reviewed to find models and correlations
2010-04-15
Numerical solutions for fully developed laminar flow in internally finned tubes with trapezoidal and triangular fin profiles were given with Finite Element Method (FEM): The heat transfer characteristics were obtained and compared under the boundary conditions of uniform heat flux, uniform wall temperature, and the third boundary condition with finite wall thermal conductivity considered. The numerical results show that boundary conditions have pronounced effects on the temperature field. Furthermore, a new mechanism on the heat transfer augmentation of internally finned tubes is proposed.
1994-06-01
Free convection heat and mass transfer to steady flow in a semi-infinite vertical porous medium
International Nuclear Information System (INIS)
Analytical solutions are derived for a flow in a semi-infinite vertical porous medium with heat and mass transfer. When the temperature and mass concentration are uniform a constant pressure is possible and sustains a fully developed flow. Thereafter there is a small perturbation on the wall temperature and concentration and the subsequent two-dimensional problem is tackled for a large Prandtl number, free convection parameters and small Reynolds number. The heat transfer rate at the wall is discussed quantitatively. (author). 4 refs.
2010-06-01
Flow Regime Map Models for the Horizontal and Vertical Pipes for the SPACE code
Energy Technology Data Exchange (ETDEWEB)
A safety analysis code, named as SPACE, for a pressurized water reactor is under development to obtain a licensing to be used for the PWR design and to hold entire proprietary rights. The task of KAERI is to develop the physical models and correlations which are required to solve the field equations. It can be divided into four parts; i) flow regime determination, ii) wall heat transfer, iii) wall and interfacial friction, iv) interfacial heat and mass transfer. This paper will describe the process to develop the models for the two-phase flow regime maps in the horizontal and vertical pipes.
2008-05-15
Flow Regime Map Models for the Horizontal and Vertical Pipes for the SPACE code
International Nuclear Information System (INIS)
A safety analysis code, named as SPACE, for a pressurized water reactor is under development to obtain a licensing to be used for the PWR design and to hold entire proprietary rights. The task of KAERI is to develop the physical models and correlations which are required to solve the field equations. It can be divided into four parts; i) flow regime determination, ii) wall heat transfer, iii) wall and interfacial friction, iv) interfacial heat and mass transfer. This paper will describe the process to develop the models for the two-phase flow regime maps in the horizontal and vertical pipes.
2008-05-01
Evaluation of tritiated water retention capacity of fusion reactor concrete building
Energy Technology Data Exchange (ETDEWEB)
In this paper the diffusion of tritiated water vapor into concrete walls is studied to evaluate tritiated water retention capacity of a fusion reactor concrete building. Using a model of the tritiated water diffusion determined form experimental results, depth profiles of tritiated water in concrete are calculated in the case of being exposed to air containing tritiated water vapor during the normal operational condition of a fusion reactor. A 0.5-m-thick concrete is sufficient for reactor hall walls from a viewpoint of the tritium containment.
1992-03-01
Evaluation of tritiated water retention capacity of fusion reactor concrete building
International Nuclear Information System (INIS)
In this paper the diffusion of tritiated water vapor into concrete walls is studied to evaluate tritiated water retention capacity of a fusion reactor concrete building. Using a model of the tritiated water diffusion determined form experimental results, depth profiles of tritiated water in concrete are calculated in the case of being exposed to air containing tritiated water vapor during the normal operational condition of a fusion reactor. A 0.5-m-thick concrete is sufficient for reactor hall walls from a viewpoint of the tritium containment.
Domain wall pining in a jointed ferromagnetic nano-wire
Energy Technology Data Exchange (ETDEWEB)
The magnetoresistance in an FeNi submicron-structure comprising two wires of 80 and 200 nm in width connected in series was measured at 77 K. When the external magnetic field was applied parallel to the wire axis, two switching fields corresponding to the distinct coercive force of the two wires were observed. When the external magnetic field was applied at an angle of {theta}>30 deg. to the wire axis one switching field was observed, indicating simultaneous magnetization reversal in both wires. This indicates that the domain-wall trapping around the joint can be controlled systematically in terms of the direction of the external magnetic field.
2004-05-01
Energy Technology Data Exchange (ETDEWEB)
Alpha particle confinement is necessary for ignition of a D-T tokamak fusion plasma and for first wall protection. Due to high radiation backgrounds and temperatures, scintillators and semiconductor detectors may not be used to study alpha particles which are lost to the first wall during the D-T programs on JET and ITER. An alternative method of charged particle spectrometry capable of operation in these harsh environments, is proposed: it consists of thin foils of electrically isolated conductors with the flux of alpha particles determined by the positive current flowing from the foils. 2 refs., 3 figs.
1994-07-01
Development of electro-optical instrumentation for annular two-phase flow studies
International Nuclear Information System (INIS)
The development of new electro-optical instrumentation for studying the annular dispersed two-phase flow regime is described. The system measures the thickness of the water film and droplet size and velocity distributions which would be encountered in such a flow regime. The water film thickness is measured by an improved capacitance method with a short time constant using newly developed sensor electrodes. The electrodes are made flush with the inner wall of a cylindrical tube and do not disturb the flow. In the test equipment, steady, laminar flow of water along the inner wall of the tube is controlled by appropriate valves and a porous jacket while droplets are introduced by means of a special spray nozzle.
1981-01-01
Energy Technology Data Exchange (ETDEWEB)
An anaerobic fermenter-decanter for the purification of residual water from the sugar industry, with recovery of methane, consists of a tank with inclined walls, with a central agitator on a vertical shaft. A flexible cover anchored by its periphery to the walls of the tank and totally submerged forms a collecting pocket for the fermentation gases. The water to be purified is introduced, after being heated to about 35, towards the bottom of the tank near the agitator. A metal collecting bell with submerged edges and with the shaft of the agitator passing axially through it is connected by its edges to a central opening of the cover. The purification yields may exceed 90%.
1981-10-06
Energy Technology Data Exchange (ETDEWEB)
A borehole televiewer (BHTV) logging was conducted to investigate cracks in bored wells. The logging process shoots ultrasonic waves onto bore walls and utilizes reflection waves from the bore walls. If the bores are filled with muddy water, or the ultrasonic waves can pass through even if vinyl chloride tubes have been inserted after excavation, the state of the bore walls can be investigated in principle. Conventional optical scanners are, however, incapable of making this investigation. The BHTV logging can be used for identifying lithofacies from reflection intensities from bore walls (it depends on sound impedance of rocks), not to speak of finding cracks. As a result of making logging upon setting time windows from 105 to 145 {mu} sec in a bored well inserted with a vinyl chloride tube, cracks in the bore wall were identified clearly through the vinyl chloride tube. If the ...
1997-05-27
International Nuclear Information System (INIS)
The aim of this study was to compare multidetector-row computed tomography (MDCT) findings between cases of sclerosing cholangitis with autoimmune pancreatitis (SC-AIP) and infiltrative extrahepatic cholangiocarcinoma (IEC). We retrospectively assessed MDCT findings from 16 IEC cases and 13 SC-AIP cases. MDCT findings were analyzed with regard to location, length, wall thickness, contour, stricture wall enhancement pattern, proximal duct diameter, and the presence of diffuse concentric thickening in the proximal duct and gallbladder wall thickness. Stricture length, stricture wall thickness, and proximal duct diameter were significantly smaller for SC-AIP than for IEC: 19.3#+-#8.7 vs. 31.8#+-#12.0 mm (P=0.004), 2.1#+-#1.3 vs. 4.1#+-#1.3 mm (P<0.001), and 9.2#+-#3.9 vs. 13.3#+-#5.0 mm (P=0.012), respectively. SC-AIP was correlated with stricture location in both the intrapancreatic and hilar hepatic ...
2010-04-01
Energy Technology Data Exchange (ETDEWEB)
For years, the writing has been on the wall about the impact of climate change on the people, plants, animals, and habitats of Latin America and the Caribbean. Now, day-to-day experiences and eye-witness accounts from leading environmental and development groups are proving predictions to be correct. In the late 1990s, the world's pre-eminent group of climate scientists gathered under the Intergovernmental Panel on Climate Change (IPCC) and predicted a devastating range of impacts, including an increase in the intensity and number of extreme weather events exacerbating natural disasters, forest die-off, melting glaciers, and the drying out of temperate grasslands. The region's huge geographical diversity means that patterns of vulnerability to climate change are extremely varied. It also makes modelling difficult, although this is constantly improving. To avoid misunderstanding, it is important to point out that with or ...
2006-08-15
Numerical simulation of progressive inlet orifices in boiling water reactor fuel
International Nuclear Information System (INIS)
This thesis was carried out at Forsmark Nuclear Power Plant. The power plant in Forsmark consists of three boiling water reactors (BWR) which produce about 17% of Swedish electricity. In a BWR the nuclear reactions are used to boil water inside the reactor vessel. The water works both as a coolant and as a moderator and the resulting steam is used directly to run the turbines. A problem when running a BWR at low flow conditions is the density wave oscillations that might occur to the water flow inside the fuel assemblies. These oscillations arise due to the connection between power and flow rate in a heated channel with two-phase flow. In order to improve the stability performance of the channel an orifice plate is placed at the inlet of each fuel assembly. Today these orifice plates have sharp edges and a constant resistance coefficient. Experimental work has been done with progressive orifices, the edge of which is half-oval in shape. The advantage of progressive orifices is the ...
2004-01-01
International Nuclear Information System (INIS)
This paper provides information on heat transfer enhancement due to jet mixing inside a cylindrical enclosure. The work addresses conservative heat transfer assumptions regarding mixing and condensation that have typically been incorporated into passive containment design analyses. The current research presents an interesting possibility for increasing decay heat removal of passive containment systems under combined natural and forced convection. Eliminating these conservative assumptions could provide the basis for a change of containment design and reduce the construction cost. It is found that the ratio of forced- and free convection Nusselt numbers can be predicted as a function of the Archimedes number and a correlated factor accounting for jet orientation and enclosure geometry. To use the small-scale tests for large containment design, scale-up methods and criteria are important for matching the key governing parameters and fluid properties. In the present ...
2001-06-17
The feasibility study of hot cell decontamination by the PFC spray method
International Nuclear Information System (INIS)
The characteristics of per-fluorocarbon compounds (PFC) are colorless, non-toxic, easily vaporized and nonflammable. Also, some of them are liquids of a high density, low surface tension, low latent heat and low specific heat. These particular chemical and physical properties of fluoro-organic compounds permit their use in very different fields such as electronics, medicine, tribology, nuclear and material science. The Sonatol process was developed under a contract with the DOE. The Sonatol process uses an ultrasonic agitation in a PFC solution that contains a fluorinated surfactant to remove radioactive particles from surfaces. Filtering the suspended particles allows the solutions to be reused indefinitely. They applied the Sonatol process to the decontamination of a heterogeneous legacy Pu-238 waste that exhibited an excessive hydrogen gas generation, which prevents a transportation of such a waste to a Waste Isolation Pilot Plant. Korea Atomic Energy Research Institute (KAERI) is ...
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
Nuclear medicine and magnetic resonance imaging (MRI) are widely used in cardiac diagnostics. Both techniques have been carefully evaluated and are equivalent for the assessment of regional and global wall motion as well as the evaluation of ejection fraction and cardiac volumes, though MRI is herein currently seen as gold standard. For evaluation of myocardial perfusion, extensive data exist for nuclear imaging, that, next to high diagnostic accuracy for evaluation of coronary artery disease, show incremental prognostic information and allow for independent risk stratification. Because of rapid technical advance, myocardial perfusion imaging has also become feasible with cardiac MRI. Results of recent studies are promising, but the data are few compared to perfusion scintigraphy. For viability assessment in patients with ischemic cardiomyopathy, positron emission tomography (PET) with FDG is currently seen as gold standard. However, single photon emission computed ...
2003-12-01
Pressure and impulse scaling methods for wall impact in ICF (inertial confinement fusion)
Energy Technology Data Exchange (ETDEWEB)
The design of the first structural wall (FSW) in an inertial confinement fusion (ICF) reactor requires some knowledge of the expected wall loading produced by x-ray and neutron deposition; specifically in the High Yield Lithium Injection Fusion Energy (HYLIFE) reactor, wall loading results from two sources -- gas shock and liquid impact. Gas shock is derived from x-ray deposition in the thin layers of exposed blanket material, producing ionized vapor, which will generate gas shock on the FSW. Liquid impact, on the other hand, results from the acceleration of liquid blanket material by two possible forces -- the drag from vapor expansion through the blanket material and the neutron-induced isochoric disassembly process. Both impacts, however, are coupled by the interaction of hot gas expanding through the liquid blanket. This paper discusses scaling methods for estimating pressure and impulse on the HYLIFE FSW from these ...
1990-01-01
Diverter/bop system and method for a bottom supported offshore drilling rig
Energy Technology Data Exchange (ETDEWEB)
A system is described adapted for alternative use as a diverter or a blowout preventer for a bottom supported drilling rig and adapted for connection to a permanent housing attached to rig structural members beneath a drilling rig rotary table, the permanent housing having an outlet connectable to a rig fluid system flow line. The system consists of: a fluid flow controller having a controller housing with a lower cylindrical opening and an upper cylindrical opening and a vertical path therebetween and a first outlet passage and a second outlet passage provided in its wall, a packing element disposed within the controller housing, and annular piston means adapted for moving from a first position to a second position, whereby in the first position the piston means wall prevents interior fluid from communicating with the outlet passages in the controller housing wall and in the second position the piston means ...
1986-07-01
Microbial volatile organic compounds (MVOCs) emitted from the mould species Penicillium expansum, P. chrysogenum, Aspergillus versicolor, A. fumigatus, A. niger and Cladosporium cladosporoides were analyzed by means of solid phase microextraction (SPME) and GCMS. The mould species were cultivated on the synthetic agar dichloran chloramphenicol (DG 18) and on wet wall paper. The production of MVOCs was monitored over several weeks to detect changes in the emission rates between the initial stage and later periods of growth. The cultivation on the synthetic agar resulted in MVOC patterns with a wide variety of signals. In contrast, the growth on wet wall paper led to changed MVOC patterns with less signals. The emission rates were drastically reduced. Components emitted by all six fungi species on wall paper were 2-pentanol and 2-pentanone. 1-Octen-3-ol was emitted by five fungi species. 2-Pentanol was only detected in ...
2008-06-05
Boiling heat transfer in compact heat exchangers
Energy Technology Data Exchange (ETDEWEB)
Small circular and noncircular channels are representative of flow passages in compact evaporators and condensers. This paper describes results of an experimental study on heat transfer to the flow boiling of refrigerant- 12 in a small circular tube of diameter = 2.46 mm. The objective of the study was to assess the effect of channel size on the heat transfer coefficient and to obtain additional insights relative to the heat transfer mechanisms. The flow channel was made of brass and had an overall length of 0.9 m. The channel wall was electrically heated, and temperatures were measured on the channel wall and in the bulk fluid stream. Voltage taps were located at the same axial locations as the stream thermocouples to allow testing over an exit quality range of 0.21 to 0.94 and a large range of mass flux (63 to 832 kg/m{sup 2}s) and heat flux (2.5 to 59 kW/m{sup 2}). Saturation pressure was nearly constant, averaging 0.82 MPa for most of the ...
1994-12-31
Analysis of enclosed sodium pool fire scenario in sodium fire experimental facility
International Nuclear Information System (INIS)
Liquid sodium is used as coolant in Fast Breeder Reactors (FBR). There is a likelyhood of sodium spillage in ambient air in the Steam Generator Building (SGB) of the FBR plant. Due to high chemical reactivity with oxygen, especially at temperatures greater than 573 K, it catches fire very easily. In order to carryout safety related experimental studies for different modes of sodium fires and to develop suitable mathematical models for the assessment of their consequences, an experimental facility (SFEF, Sodium Fire Experimental Facility) is being setup a IGCAR, Kalpakkam. The SFEF is having a 540 m"3 volume experimental hall. Stainless steel linear will be provided on the inside surfaces of experimental hall walls, ceiling and floor. Analysis has been carried out for enclosed sodium pool fire scenarios in SFEF by using sodium pool fire code SOFIRE II, which estimates the thermal transients like pressure rise, gas temperature rise, cell wall ...
2007-04-22
International Nuclear Information System (INIS)
In this paper, a phenomenological model of the thermal hydraulics of convective boiling in the post-critical-heat-flux (post-CHF) regime is developed and discussed. The model was implemented in the TRAC-PF1/MOD2 computer code (an advanced best-estimate computer program written for the analysis of pressurized water reactor systems). The model was built around the determination of flow regimes downstream of the quench front. The regimes were determined from the flow-regime map suggested by Ishii and his coworkers. Heat transfer in the transition boiling region was formulated as a position-dependent model. The propagation of the CHF point was strongly dependent on the length of the transition boiling region. Wall-to-fluid film boiling heat transfer was considered to consist of two components: first, a wall-to-vapor convective heat-transfer portion and, second, a wall-to-liquid heat transfer representing ...
1983-10-14
Aespoe Pillar Stability Experiment. Acoustic emission and ultrasonic monitoring
Energy Technology Data Exchange (ETDEWEB)
This report describes the results from acoustic emission (AE) and ultrasonic monitoring of the Aespoe Pillar Stability Experiment (APSE) at SKB's Hard Rock Laboratory (HRL), Sweden. The APSE is being undertaken to demonstrate the current capability to predict spalling in a fractured rock mass using numerical modelling techniques, and to demonstrate the effect of backfill and confining pressure on the propagation of micro-cracks in rock adjacent to deposition holes within a repository. An ultrasonic acquisition system has provided acoustic emission and ultrasonic survey monitoring throughout the various phases of the experiment. Results from the entire data set are provided with this document so that they can be effectively compared to several numerical modelling studies, and to mechanical and thermal measurements conducted around the pillar volume, in an 'integrated analysis' performed by SKB staff. This document provides an in-depth summary of the AE and ...
2005-12-15
Potential Increases in Mortality due to Global Warming
... predicting potential increases in human mortality due to global warming....
Energy Technology Data Exchange (ETDEWEB)
Numerical solutions given by a vorticity-velocity method are presented for combined free and forced laminar convection in the thermal entrance region of a horizontal rectangular channel without the assumptions of large Prandtl number and small Grashof number. The channel wall is heated with a uniform wall heat flux. Typical developments of temperature profile, secondary flow, and axial velocity at various axial positions in the entrance region are presented. Local friction factor and Nusselt number variations are shown for Rayleigh numbers Ra = 10{sup 4}, 3 {times} 10{sup 4}, 6 {times} 10{sup 4}, and 10{sup 5} with the Prandtl number as a parameter. The solution for the limiting case of large Prandtl number and small Grashof number obtained from the present study confirms the data of existing literature. It is observed that the large Prandtl number assumption is valid for Pr = 10 when Ra {le} 3 {times} 10{sup 4} but for a larger Prandtl number ...
1987-08-01
Energy Technology Data Exchange (ETDEWEB)
Vanadium alloys exhibit important advantages as a candidate structural material for fusion first wall/blanket applications. These advantages include fabricability, favorable safety and environmental features, high temperature and high wall load capability, and long lifetime under irradiation. Vanadium alloys with (3-5)% chromium and (3-5)% titanium appear to offer the best combination of properties for first wall/blanket applications. A V-4Cr-4Ti alloy is recommended as the reference composition for the ITER application. This report provides a summary of the R&D conducted during 1994 in support of the ITER Engineering Design Activity. Progress is reported for Vanadium Alloy Production, Welding, Physical Properties, Baseline Mechanical Properties, Corrosion/Compatibility, Neutron Irradiation Effects, Helium Transmutation Effects on Irradiated Alloys, and the Status of Irradiation Experiments. Separate abstracts have been ...
1995-03-01
Thermal-mechanical test on ITER primary first wall mock-ups
International Nuclear Information System (INIS)
In 1998, in the frame of the ITER EDA phase, an European R and D Programme for the Blanket Design was implemented for developing and selecting the materials and the relevant fabrication procedures for manufacturing the shielding modules of the ITER Primary Wall. The fabrication of several Beryllium armored small scale mock-ups, reproducing representative portions of a Primary Wall panels, was also launched (Fusion Technol. (1998) 195). Further experimental activities were also programmed for investigating the thermal-mechanical behavior of these mock-ups at high heat flux and under thermal fatigue tests. In 2001, the ITER European Home Team decided to assign to ENEA a contract for the thermal fatigue testing of six mock-ups aiming at verifying the reliability of the Beryllium/Dispersion Strengthened Copper alloy/Stainless Steel and Beryllium/Precipitation hardened Copper alloy/Stainless Steel joints manufactured by solid Hot Isostatic Pressing ...
2002-11-01
International Nuclear Information System (INIS)
Considerations for longevity of nuclear facilities and ease of decommissioning are of great importance for future nuclear power plants. To this end, a concept of an optimal structural concept for nuclear reactor buildings has been studied: the main feature of this concept is to utilize large-sized, light weight prefabricated members with ultrahigh strength materials. The following two items have been selected to study the prospective structure: (1) Applicability of ultrahigh strength materials for reinforced concrete shear walls (2) Construction using large sized prefabricated members As the first step (1), material and structural tests using ultrahigh strength materials, and the subsequent analysis of those tests for reinforced concrete shear walls, has been conducted. The positive results of this study show a bright future for the use of ultrahigh strength materials for the reinforced concrete shear walls of nuclear ...
1993-08-15
Energy Technology Data Exchange (ETDEWEB)
Leak-before-break (LBB) analyses for circumferentially cracked pipes are currently being conducted in the nuclear industry to justify elimination of pipe whip restraints and jet impingement shields which are present because of the expected dynamic effects from pipe rupture. The application of the LBB methodology frequently requires calculation of leak rates. These leak rates depend on the crack-opening area of a through-wall crack in the pipe. In addition to LBB analyses, which assume a hypothetical flaw size, there is also interest in the integrity of actual leaking cracks corresponding to current leakage detection requirements in NRC Regulatory Guide 1.45, or for assessing temporary repair of Class 2 and 3 pipes that have leaks as are being evaluated in ASME Section 11. This study was requested by the NRC to review, evaluate, and refine current analytical models for crack-opening-area analyses of pipes with circumferential through-wall ...
1995-04-01
Progress on fatigue characterization of ITER primary first wall mock-ups
International Nuclear Information System (INIS)
In 2001, EFDA has assigned to ENEA a contract for the thermomechanical testing of six mock-ups of the ITER primary wall module. These small scale mock-ups, reproducing representative portions of the reference ITER primary wall panels, were fabricated during ITER EDA phase by solid hot isostatic pressing (HIPping) of an AISI 316L stainless steel back structure to a alumina dispersion strengthened (DS)-Cu alloy heat sink armored with beryllium tiles. The experimental program, carried-out at ENEA Brasimone CEF 1-2 thermal hydraulic facility, was focused on the thermal mechanical testing of these mock-ups aiming at verifying which tile geometry and manufacturing procedure assures the required reliability of the beryllium/DS-Cu alloy/SS joints at high incident heat flux (>0.8 MW/m"2) both at steady state and under thermal fatigue tests. The paper presents the progress in the experimental activity of the first test campaign and the main ...
2003-09-01
Energy Technology Data Exchange (ETDEWEB)
The authors investigate the optimisation of solar-heated cavity receivers in which solar energy collected by a paraboloid collector is converted into electrical energy. The focussed solar energy enters the receiver through an aperture to heat the working fluid, which flows inside the receiver tubes and is compressed by the compressor of a gas turbine system, to the highest process temperature. A method of calculating the distribution on the inner receiver surfaces of the solar radiation reflected by the paraboloid collector is presented to begin with. The interchange of radiant energy inside the receiver cavity can be calculated on this basis, including the radiation loads, the temperatures of the inner receiver walls, and the radiative and convective losses. The temperature fields in the tube walls must be known for determining the strength required of receiver tubes; they can be derived from the useful heat which comprises a directed ...
1984-01-01
Energy Technology Data Exchange (ETDEWEB)
Laboratory experiments were conducted to simulate the transfer of acidic THOREX waste from Tank 8D-4 into the alkaline PUREX waste in Tank 8D-2 at West Valley. The purpose of the experiments was to explore means of minimizing the production of nitric oxide (NO) gas during mixing of the two wastes and to assess the potential for the gas to further react in the vapor space possibly leading to enhanced corrosion of the tank walls. Forty one THOREX/PUREX mixing tests were conducted to explore the effects of stirring rate, pH, THOREX addition rate, THOREX or PUREX dilution, and temperature. The two most important criteria for minimizing NO production were to maintain some degree of agitation and the keep the pH in the PUREX high, preferably >12. Steel corrosion tests were performed in the presence of low partial pressures of NO{sub 2} and liquid water or water vapor. The NO{sub 2} (from oxidation of NO in the vapor space) concentrations were representative of those ...
1995-05-01
Innovative coke-oven repair techniques
Energy Technology Data Exchange (ETDEWEB)
Certain innovative coke-oven repair techniques are reviewed that represent an engineered approach to a successful rehabilitation of all types of coke-oven batteries. These techniques have been developed during the last 10 years and experience gained on a number of repair projects has shown that these techniques operate as a cohesive and comprehensive method of end flue and through-wall repairs to gain additional years of operating life to coke-oven batteries. Extended operations approaching 10 to 15 additional years of service at lower costs than a pad-up rebuild and, while meeting the environmental emission regulations, are attainable using the techniques of: Proper tie-in joint preparation; Improved bricking up methodology; Preheating refractory during bricking up; Installation of spring-loaded bracing system; and installation of flexible coke-oven doors. Repair methods that do not incorporate the above techniques are subject to premature failure of the ...
1995-10-01
GDH pipe break transient analysis of the RBMK - 1500.
Energy Technology Data Exchange (ETDEWEB)
Presented in this paper is the transient analysis of a Group Distribution Header (GDH) following a guillotine break at the end of the header. The GDH is the most important component of reactor safety in case of accidents. Emergency Core Cooling System (ECCS) piping is connected to the GDH piping such that, during an accident, coolant passes from the GDH into the ECCS. The GDH that is propelled into motion after a guillotine break can impact neighboring GDH pipes or the nearest wall of the compartment. The cases of GDH impact on an adjacent GDH and its attached piping are investigated in this paper. A whipping RBMK-1500 GDH along with neighboring concrete walls and pipelines is modeled using finite elements. The finite element code NEPTUNE used in this study enables a dynamic pipe whip structural analysis that accommodates large displacements and nonlinear material characteristics. The results of the study indicate that a whipping GDH pipe would ...
2002-05-15
Diverter/bop system and method for a bottom supported offshore drilling rig
Energy Technology Data Exchange (ETDEWEB)
This patent describes a system adapted for alternative use as a diverter or a blowout preventer for a bottom supported drilling rig and adapted for positioning beneath a rotary table of the drilling rig, the system comprising: a fluid flow controller having a controller housing with a lower opening and an upper opening and a vertical flow path therebetween and an outlet passage provided in its housing wall, and at least two bases. A method is described for installing a system adapted for alternative connection as a diverter or a blowout preventer for a bottom supported drilling rig positioned beneath a rotary table of the drilling rig after structural casing has been set in a borehole. The method comprises: positioning a first telescoping spool having a lower end and an upper end below the rotary table, the first spool having a first base disposed at its upper end, the first base having a port disposed in its wall; aligning a fluid flow ...
1987-03-03
Deuterium retention in titanium alloys exposed in PLT
International Nuclear Information System (INIS)
Specimen strips of pure alpha titanium and beta titanium alloy were exposed to a range of up to 46 deuterium plasma discharges in the Princeton Large Torus Tokamak (PLT) under simulated first wall conditions, and the amount of trapped deuterium in these specimens was measured, using carbon as a calibration standard for trapping. The Deuterium Nuclear Microprobe was used to study the total trapped deuterium and the deuterium depth distribution in the exposed materials before and after annealing at 373 and 423"0K. The Scanning Auger Microprobe was used to identify the effects of surface impurities on the deuterium distribution. Results indicate that about 20 to 40% of the incident deuterium was trapped by the surface and about 90% of the trapped deuterium remained in a 20A carbonaceous film deposited during plasma exposure. Annealing resulted in a gradual loss from the film. These results indicate the importance of impurity film formation which may play a dominating ...
1981-07-01
International Nuclear Information System (INIS)
We compared the values of the myocardial thickness and the left ventricle diameters measured with MRI and echocardiography. The ejection fraction was compared in MRI and ventriculography. 34 patients with different heart dysfunctions were examined with MRI (FISP 2D sequence). 26 of them were also studied by echocardiography and 20 by biplane cine-ventriculography. The enddiastolic thicknesses of the left ventricular postero-lateral wall and of the septum interventriculare were measured on short axis images. An ellipsoidal modell was used for volume calculation and ejection fraction. Correlation of MRI values of thickness and ejection fraction with echocardiographi and angiographi showed r>0,8. As known for 1.56 T Imagers, the myocardial thickness in MRI was underestimated compared to echocardiography (1.4 mm#+-#1.7). The ejection fraction was underevaluated compared to ventriculography (4.5%#+-#10.1). MRI (1.0 T) accurately measures ventricular ...
Desorption of polycyclic aromatic hydrocarbons from carbon nanomaterials in water
Energy Technology Data Exchange (ETDEWEB)
Desorption behavior of pyrene, phenanthrene and naphthalene from fullerene, single-walled carbon nanotubes (SWCNTs) and multi-walled carbon nanotubes (MWCNTs) was examined. Available adsorption space of carbon nanotubes (CNTs) was found to be the cylindrical external surface, neither the inner cavities nor inter-wall spaces due to impurities in the CNTs and restricted spaces (0.335 nm) of the MWCNTs, respectively. Desorption hysteresis was observed for fullerene but not for CNTs. Deformation-rearrangement was proposed to explain the hysteresis of polycyclic aromatic hydrocarbons (PAHs) for fullerene, due to the formation of closed interstitial spaces in spherical fullerene aggregates. However, long, cylindrical carbon nanotubes could not form such closed interstitial spaces in their aggregates due to their length, thus showing no significant hysteresis. High adsorption capacity and reversible adsorption of PAHs on CNTs ...
2007-01-15
Concrete as secondary containment for interior wall embedded waste lines
International Nuclear Information System (INIS)
Throughout the DOE complex there are numerous facilities that handle hazardous and radioactive waste solutions. Due to the hazardous constituents of the mixed waste, secondary containment of tank systems and their ancillary piping, in accordance with Resource Conservation and Recovery Act, is a concern for such existing facilities. The Idaho Division of Environmental Quality was petitioned in 1990 for an Equivalent Device determination regarding secondary containment of waste lines embedded in interior concrete walls. The petition was granted; however, it expires in 1996. To address the secondary containment issue, additional studies were undertaken. One study verified the hypothesis that an interior wall pipe leak would follow the path of least resistance through the naturally occurring void found below a rigidly supported pipe and pass into an adjacent room where detection could occur, before any significant deterioration of the concrete ...
1993-08-17
Vessel elements present in the secondary xylem of Trochodendron and Tetracentron (Trochodendraceae)
British Library Electronic Table of Contents (United Kingdom)
For almost 150 years, the two monotypic genera Trochodendron and Tetracentron (Trochodendraceae) have been considered to share an unusual and primitive feature in angiosperms - the lack of vessels in their wood. Therefore, they have been classified in a basal position in the angiosperms. Our observations by light microscopy, low-vacuum environmental scanning electron microscopy (ESEM) and high-vacuum scanning electron microscopy (SEM) both in fresh and FAA-fixed materials consistently showed the presence of tracheary elements differentiated into two types in both genera. In Trochodendron, the tracheary elements can be divided into perforate vessel elements and imperforate fiber-tracheids and tracheids. The vessel elements show end and lateral walls. The pits on the end walls are elongate- ...
2011-01-01
True and measured outgassing rates of a vacuum chamber with a reversibly adsorbed phase
Energy Technology Data Exchange (ETDEWEB)
A pump down model for a vacuum chamber with a reversibly adsorbed phase is presented. The outgassing equation which predicts the variation of coverage at the wall surface of a vacuum chamber with time is derived. Then the measured and the true outgassing rates are defined. The theoretical measured outgassing rate shows only a very weak dependence for pumping speed. This prediction is opposite to the experimental result that the measured outgassing rate depends significantly on pumping speed. It is discussed that the experimental measured outgassing rate must be described as the product of the effective pumping speed and the measured pressure in the pumped chamber, in which the measured pressure is equivalent to the equilibrium pressure of the wall surface described by the equilibrium adsorption isotherm as a function of the shifted surface coverage {theta}-{delta}{theta} by a small coverage {delta}{theta} from the coverage of a pumping point ...
2000-03-01
British Library Electronic Table of Contents (United Kingdom)
Abstract Purpose: To evaluate the efficacy of transvesical obturator nerve block (ONB) in the prevention of obturator nerve reflex and leg jerking during transurethral resection of bladder tumors (TURBT). Patients and Methods: A total of 60 patients were studied, in whom the transurethral resection of tumors on the posterolateral bladder wall were performed under spinal anesthesia (SA). The patients were randomly divided into two groups. In the first group, we performed transvesical ONB and SA together, while the second group received only SA. The patients underwent TURBT using monopolar cautery. Incidence of leg jerking was registered and compared in these two groups. We used a nerve stimulator to detect the obturator nerve next to the lateral bladder wall. The obturator nerve was identif...
2010-01-01
Thermal performance simulation of a solar cavity receiver under windy conditions
British Library Electronic Table of Contents (United Kingdom)
Solar cavity receiver plays a dominant role in the light-heat conversion. Its performance can directly affect the efficiency of the whole power generation system. A combined calculation method for evaluating the thermal performance of the solar cavity receiver is raised in this paper. This method couples the Monte-Carlo method, the correlations of the flow boiling heat transfer, and the calculation of air flow field. And this method can ultimately figure out the surface heat flux inside the cavity, the wall temperature of the boiling tubes, and the heat loss of the solar receiver with an iterative solution. With this method, the thermal performance of a solar cavity receiver, a saturated steam receiver, is simulated under different wind environments. The highest wall temperature of the boi...
2011-01-01
Thermal modeling of solar central receiver cavities
Energy Technology Data Exchange (ETDEWEB)
Results are presented from a numerical model of the steady-state energy transfer in molten-salt-in-tube solar cavity receivers that includes convective energy transfer at a local (spatially resolved) level. Molten salt energy absorption and gray radiative transfer between all cavity surfaces are also included. This model is applied to the Molten Salt Subsystem Component Test Experiment (MSS/CTE) cavity receiver. Results for this receiver indicate the global (entire cavity) receiver thermal efficiency is invariant within a few percent to most parameters investigated, although front surface temperatures of the nonabsorbing walls vary considerably, and are particularly sensitive to the type of convective submodel used. Absorption efficiencies indicate the effects of the cavity enclosure environment. For all conditions investigated, tube inner wall temperatures remain under 855 K, ensuring that the salt remains chemically stable.
1989-05-01
The mechanism of uranium biosorption by Rhizopus arrhizus
Energy Technology Data Exchange (ETDEWEB)
Biosorption of elements is a little understood phenomenon exhibited by some types of even nonliving microbial biomass. A common fungus Rhizopus arrhizus has been reportd to take up uranium from adqueous solutions to the extent of 180 mg U/sup 6 +//g. The mechanism of uranium sequestering by this type of biomass was studied by using experimental techniques such as electron microscopy, x-ray energy dispersion analysis, IR spectroscopy, and supporting evidence was obtained for a biosorption mechanism consisting of at least three processes. Uranium coordination and adsorption in the cell-wall chitin structure occur simultaneously and rapidly whereas precipitation of uranylhdroxide within the chitin microcrystalline cell-wall structure takes place at a lower rate. Interference of Fe/sup 2/ and Zn/sup 2 +/ coions with uranium biosorption is indicated.
1982-02-01
The mechanism of thorium biosorption by Rhizopus arrhizus
Energy Technology Data Exchange (ETDEWEB)
Inactive cells of Rhizopus arrhizus have been documented to exhibit a high thorium biosorptive uptake (170 mg/g) from aqueous solutions. The mechanism of thorium sequestering by this biomass type was investigated following the same method as for the uranium biosorption emchanism. The thorium sequestering mechanism appeared somewhat different from that of uranium. Experimental evidence is presented which indicates that, at optimum biosorption pH (4), thorium coordinates with the nitroge of the chitin cell wall network and, in addition, more thorium is adsorbed by the external section of the fungal cell wall. At pH 2 the overall thorium uptake is reduced. The kinetic study of thorium biosorption revealed a very rapid rate of uptake. Unlike uranium at optimum solution pH, Fe/sup 2 +/ and Zn/sup 2 +/ did not interfere significantly with the thorium biosorptive uptake capacity of R. arrhizus.
1982-04-01
British Library Electronic Table of Contents (United Kingdom)
Scanning electron microscope (SEM) is necessary to demonstrate presence or absence of pit membranes in possible perforations or the type of pit membrane remnants in perforations in vessel element end-walls of angiosperms, but it was unconfirmed and questionable whether pit membrane absence in pits was affected by the processing and handling before SEM observations. To solve this question, the secondary xylem of four woody species from primitive angiosperms, Illicium henryi Diels. (Illiciaceae), Schisandra rubriflora (Franch.) Rehd. et Wils. (Schisandraceae), Tetracentron sinensis Oliv. and Trochodendron aralioides Sieb. & Zucc. (Trochodendraceae) was chosen and the following techniques were used: (1) fresh materials were examined in low-vacuum with ESEM. (2) Air-dried materials were examin...
2011-01-01
TIG of Reduced Activation Ferrite/Martensitic Steel for the Korean ITER-TBM
International Nuclear Information System (INIS)
Test Blanket Modules (TBM) will be tested in ITER to verify the capability of tritium breeding and recovery and the extraction of thermal energy suitable for the production of electricity. A Helium Cooled Solid Breeder (HCSB) TBM has been developed in Korea to accomplish these goals. Reduced Activation Ferritic/Martensitic (RAFM) steel has been chosen as the primary candidate structural material for Korean TBM. Due to the complexity of the First wall (FW) and Side wall (SW), it is necessary to develop various joining technologies, such as Hot Isostatic Pressing (HIP), Electron Beam Welding (EBW) and Tungsten Inert Gas (TIG) welding, for the successful fabrication of TBM. In this study, the mechanical properties of TIG welded RAFM steel were investigated. Various mechanical tests of TIG-welded RAFM steel were performed to obtain the optimized TIG welding process for RAFM steel
2010-10-01
Sheathed cold-formed steel housing: A seismic design procedure
British Library Electronic Table of Contents (United Kingdom)
Nowadays, different research teams are engaged on experimental and theoretical studies having as main aim the evaluation of seismic performance of sheathed cold-formed steel frame structures. Although a relatively large number of experimental and theoretical studies are available, the development of useful tools for the seismic design should be improved. As an attempt to overcome this lack, this paper aims to present a structural design procedure that allows, through the definition of three design nomographs, the screw spacing and all the shear walls components to be obtained on the basis of linear dynamic or nonlinear static seismic analysis. In addition, a procedure for the prediction of the whole pushover response curve of sheathed cold-formed steel shear walls, which can be advantageou...
2009-01-01
Secondary electron yield measurements from thin surface coatings for NLC electron cloud reduction
In the beam pipe of the positron damping ring of the Next Linear Collider, electrons will be created by beam interaction with the surrounding vacuum chamber wall and give rise to an electron cloud. Several solutions are possible for avoiding the electron cloud, without changing the bunch structure or the diameter of the vacuum chamber. Some of the currently available solutions for preventing this spurious electron load include reducing residual gas ionization by the beam, minimizing beam photon-induced electron production, and lowering the secondary electron yield (SEY) of the chamber wall. We will report on recent SEY measurements performed at SLAC on TiN coatings and TiZrV non-evaporable getter thin films.
2004-01-01
STATUS OF THE DIELECTRIC WALL ACCELERATOR
Energy Technology Data Exchange (ETDEWEB)
The dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL) uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system is capable of accelerating any charge to mass ratio particle. Applications of high gradient proton and electron versions of this accelerator will be discussed. The status of the developmental new technologies that make the compact system possible will be reviewed. These include, high gradient vacuum insulators, solid dielectric materials, photoconductive switches and compact proton sources.
2009-04-22
Rigorous and General Definition of Thermodynamic Entropy
The physical foundations of a variety of emerging technologies --- ranging from the applications of quantum entanglement in quantum information to the applications of nonequilibrium bulk and interface phenomena in microfluidics, biology, materials science, energy engineering, etc. --- require understanding thermodynamic entropy beyond the equilibrium realm of its traditional definition. This paper presents a rigorous logical scheme that provides a generalized definition of entropy free of the usual unnecessary assumptions which constrain the theory to the equilibrium domain. The scheme is based on carefully worded operative definitions for all the fundamental concepts employed, including those of system, property, state, isolated system, environment, process, separable system, system uncorrelated from its environment, and parameters of a system. The treatment considers also systems with movable internal walls and/or semipermeable walls, with ...
2010-01-01
Preparation of reactor tube by welding a porous membrane with a non-porous ceramic tube
Energy Technology Data Exchange (ETDEWEB)
In the course of designing a catalytic porous membrane reactor for experimental studies, both inside and outside of the non-reaction zones as well as the two ends of the membrane need to be completely sealed to ensure that there is no flow across the membrane in the non-reaction zone. Experiments show that up to 50% of the total flow across the membrane may be contributed by the axial flow along the wall of the non-reaction zones if only one side of the membrane is sealed. Another problem that cannot be solved by sealing is the capillary flow of the catalyst along the tube wall into the non-reaction zones when the catalyst is doped on the membrane. One of the best ways to avoid this axial flow of catalyst would be to use non-porous tubes in the non-reaction zones and join them with the porous membrane tube. In doing so, the cost of the membrane reactor could be reduced simply because shorter membrane tube is needed.
1994-12-31
Modeling of a self-excited pulse combustor and stability analysis
British Library Electronic Table of Contents (United Kingdom)
The major bottleneck for popularization and utilization of the conventional mechanical valve pulse combustors is the self-priming mode of gas supply. An aerodynamic valve (as against mechanical valve) self-excited pulse combustor of the Helmholtz-type with continuous supply of gas and air was designed and a mathematical model was established in this paper. The theoretical model employed well-stirred reactor model and a single step Arrhenius chemistry, and took those factors which might affect the combustion stability into account. The factors include the variation of the mass rate of the reactants affected by the pressure in the combustion chamber, the convective and radiation heat loss in the combustion chamber, and the heat transfer and wall friction in the tailpipe. The effect of wall t...
2011-01-01
Junction conditions in General Relativity with spin sources
The junction conditions for General Relativity in the presence of domain walls with intrinsic spin are derived in three and higher dimensions. A stress tensor and a spin current can be defined just by requiring the existence of a well defined volume element instead of an induced metric, so as to allow for generic torsion sources. In general, when the torsion is localized on the domain wall, it is necessary to relax the continuity of the tangential components of the vielbein. In fact it is found that the spin current is proportional to the jump in the vielbein and the stress-energy tensor is proportional to the jump in the spin connection. The consistency of the junction conditions implies a constraint between the direction of flow of energy and the orientation of the spin. As an application, we derive the circularly symmetric solutions for both the rotating string with tension and the spinning dust string in three dimensions. The rotating ...
2006-01-01
Energy Technology Data Exchange (ETDEWEB)
This research aims to develop reliable, advanced system thermal-hydraulic computer code and to quantify the uncertainties of code to introduce the best estimate methodology of ECCS for LBLOCA. Although the one of best estimate code, RELAP5/MOD3.1 was introduced from USNRC, several deficiencies in its reflood model and some improvements have been made. The improvements consist of modification of reflood wall heat transfer package and adjusting the drop size in dispersed flow regime. The tome smoothing of wall vaporization and level tracking model are also added to eliminate the pressure spike and level oscillation. For the verification of improved model and quantification of associated uncertainty, the FLECHT-SEASET data were used and upper limit of uncertainty at 95% confidence level is evaluated. (Author) 30 refs., 49 figs., 2 tabs.
1994-06-01
ITER baffle module small-scale mock-ups: first wall thermo-mechanical testing results
International Nuclear Information System (INIS)
The EU-home team is in charge of the R and D related to the ITER baffle first wall. Five small-scale mock-ups, using Be, CFC and W tiles and different armour/heat-sink material joints under development, have been fabricated and thermomechanically tested in FE200 (Le Creusot) and JUDITH (Juelich) electron beam facilities. The small-scale mock-ups have been submitted to thermo-mechanical fatigue tests (up to failure using accelerating techniques). The objective was to determine the performances of the armour material joints under high heat flux cycles. (orig.)
1998-09-01
Forced convective heat transfer in cross-corrugated solar air heaters
Forced convective heat transfer in a cross-corrugated channel solar air heater has been studied experimentally using air as a working fluid. The channel was formed by two transversely positioned corrugated sheets and two flat thermally insulated side walls. One corrugated sheet was heated by a radiant heater, while the other was thermally insulated. The fluid velocity and temperature, and the wall temperature and the local heat flux across the heated corrugated sheet were measured for a variety of operating flow rates. Experimental results for the channel geometry have yielded the correlation Nu = 0.0743 (Re)[sup 0.76]. This heat-transfer coefficient is about 2.8 times that of a smooth flat channel. The experiments showed that local heat transfer rate was smaller on the valley of the corrugation than that on the peak. The ratio of the local heat transfer rates on the two locations was related to the Reynolds number.
1994-11-01
Flow field and heat transfer associated with laminar flow over a forward-facing step
The flow and heat transfers associated with a plane laminar flow past a forward-facing step were analyzed using a power-law numerical scheme combined with a false vorticity-stream function approach. To improve the traditional wall-vorticity boundary condition, a novel method, based on an accurate description of the nonslip wall condition, was developed and utilized. The convergence for a 56 x 49 grid system was obtained in about 350 iterations. The computed reattachment distances in the upper separated region agree with the available experimental data for a blunt plate. The heat transfer augmentation is significant across the step; however, it is counterbalanced by the deterioration of heat transfer immediately upstream of the step.
1986-01-01
Experimental investigation of wall static pressure fluctuations in parallel boiling flow
International Nuclear Information System (INIS)
Measurements of the statistical characteristics of channel wall static pressure fluctuations in parallel one-component boiling flow are reported. The measurements span a wide range of local subcooling and vapor volume fraction, and correspond to flow regimes ranging from highly subcooled bubbly to saturated slug-annular. Vapor volume fraction measurements at the pressure measurement station are also reported in conjunction with visual observation of the flow structure. Variation of static pressure fluctuation intensity and spectral content with local thermal-hydraulic condition is demonstrated. Finally, it is suggested that diagnosis of local two-phase flow regime on the basis of (i) statistical characteristics of the pressure data, and (ii) time trace of pressure signal, may be possible. 15 refs.
1980-01-01
British Library Electronic Table of Contents (United Kingdom)
An experimental study was performed to investigate the heat transfer characteristics of the mixed convection flow through a horizontal rectangular channel where open-cell metal foams of different pore densities (10, 20 and 30 PPI) were situated. A uniform heat flux was applied at all of the bounding walls of the channel. For each of three values of the uniform heat flux, temperatures were measured on the entire surfaces of the walls. Results for the average and local Nusselt numbers are presented as functions of the Reynolds and Richardson numbers. The Reynolds number based on the channel height of the rectangular channel was varied from 600 to 33000, while the Richardson number ranged from 0.02 to 103, extending over forced, mixed and natural convection. Second important parameter that in...
2009-01-01
Exergy transfer in a porous rectangular channel
British Library Electronic Table of Contents (United Kingdom)
Present paper is performed to investigate the heat and exergy transfer characteristics of forced convection flow through a horizontal rectangular channel where open-cell metal foams of different pore densities such as 10, 20 and 30PPI (per pore inches) were situated. All of the bounding walls of the channel are subjected to various uniform heat fluxes. The pressure drop and heat transfer characteristics are presented by two important parametric values, Nusselt number (NuH) and friction factor (f), as functions of Reynolds number (ReH) and the wall heat flux (q). The Reynolds number (ReH) based on the channel height of the rectangular channel is varied from 600 to 33 000, while the Grashof number (GrDh) ranged from approximately 105-107 depending on q. Based on the experimental data, new em...
2010-01-01
Effective diffusion coefficient of radon in concrete, theory and method for field measurements
International Nuclear Information System (INIS)
A linear diffusion model serves as the basis for determination of an effective radon diffusion coefficient in concrete. The coefficient was needed to later allow quantitative prediction of radon accumulation within and behind concrete walls after application of an impervious radon barrier. A resolution of certain discrepancies noted in the literature in the use of an effective diffusion coefficient to model diffusion of a radioactive gas through a porous medium is suggested. An outline of factors expected to affect the concrete physical structure and the effective diffusion coefficient of radon through it is also presented. Finally, a field method for evaluating effective radon diffusion coefficients in concrete is proposed and results of measurements performed on a concrete foundation wall are compared with similar published values of gas diffusion coefficients in concrete. (author).
Development of electro-optical instrumentation for annular two-phase flow studies. [PWR
Energy Technology Data Exchange (ETDEWEB)
The development of new electro-optical instrumentation for studying the annular dispersed two-phase flow regime is described. The system measures the thickness of the water film and droplet size and velocity distributions which would be encountered in such a flow regime. The water film thickness is measured by an improved capacitance method with a short time constant using newly developed sensor electrodes. The electrodes are made flush with the inner wall of a cylindrical tube and do not disturb the flow. In the test equipment, steady, laminar flow of water along the inner wall of the tube is controlled by appropriate valves and a porous jacket while droplets are introduced by means of a special spray nozzle.
1981-05-01
Determining the porosity of rock in oil wells using compensated neutron logging
Energy Technology Data Exchange (ETDEWEB)
The two-sonde neutron-logging device RKS-2 registers the ratios of the indications of two sondes and is scaled in units representing the total water content of pure limestone when saturated with fresh water. When analyzing the results of the measurements in real wells, it is necessary to calculate the effect of well- and strata conditions on the results of porosity determination. The results of simulated measurements are presented, on the basis of which correction factors are immediately determined for the calculation of the effect of the diameter of the well, and the effect of the mud cake on the well wall. A nomogram is constructed and substantiated; its purpose is the calculation of the effect of the following on the RKS-2 indication: the diameter of the well, the mud cake on the well wall, the density of the drilling solution, temperature, pressure in the well, and the lithology of the rock.
1982-01-01
The optical birefringence of rod-like nematogens (7CB, 8CB), imbibed in parallel silica channels with 10 nm diameter and 300 micrometer length, is measured and compared to the thermotropic bulk behavior. The orientational order of the confined liquid crystals, quantified by the uniaxial nematic ordering parameter, evolves continuously between paranematic and nematic states, in contrast to the discontinuous isotropic-to-nematic bulk phase transitions. A Landau-de Gennes model reveals that the strength of the orientational ordering fields, imposed by the silica walls, is beyond a critical threshold, that separates discontinuous from continuous paranematic-to-nematic behavior. Quenched disorder effects, attributable to wall irregularities, leave the transition temperatures affected only marginally, despite the strong ordering fields in the channels.
2008-01-01
Applications of the phased array technique; Anwendungsmoeglichkeiten der Gruppenstrahlertechnik
Energy Technology Data Exchange (ETDEWEB)
The application of the phased array technique was limited to heavy and thick wall components as present in the nuclear industry. With the improvement of the equipment and probes other application areas are now open for the phased array technique, e.g. the inspection of the turbine blade root, weld inspection in a wall thickness range between 12 and 40 mm, inspection of aircraft components, inspection of spot welds or inspection of concretes. The aim of the use of phased array techniques has not been changed related to the first applications, i.e. the adaptation of the sound beam to the geometry by steering the angel of incidence or the skewing angle as well as the focussing of sound fields. Due to the fact, that the new applications of the phased array techniques in some cases don't leave the laboratories for the time being, the examples of this contribution will focus applications with practical background. (orig.)
1999-07-01
1991 ice jamming along the Saint John River: a case study
Energy Technology Data Exchange (ETDEWEB)
Field investigations of major and damaging ice jamming on the Saint John River at Dickey, Maine , and at Sainte-Anne de-Madawaska, New Brunswick, in 1991, were described. The investigations included measurement of water surface profiles and shear wall heights at both sites. The measurements were supplemented by information from local observers and data collection agencies. Using a simplified equilibrium analysis, ice jam thickness and water level at the Dickey site was found to be generally in agreement with observed values. At Sainte-Anne-de-Madawaska sufficient data was obtained to construct and calibrate the numerical model RIVJAM which determined the configuration of the jam in nonequilibrium reaches. Use of the model enabled the successful reproduction of a measured water profile along the jam and the prediction of the approximate thickness of the jam, which was generally less than the measured shear wall height. 14 refs., 11 figs.
1996-04-01
Co-combustion of recycled waste materials with peat and coal in a 15 kw fluidized bed reactor
Energy Technology Data Exchange (ETDEWEB)
Co-combustion tests for recycled fuels and peat were made at a 15 kW fluidized bed reactor at VTT Energy in Jyvaeskylae. Peat was used as reference fuel. 25 tests in total were performed during 1994 - 1996. A part of the peat energy was substituted by coal in five tests, in order to change the sulphur/chlorine ratio of the fuel mixture. Fuel mixtures (25% recycled fuel and 75% peat, at energy ratio) were pelletized in order to get homogeneous fuel mixtures. The tests in the year 1994 were air staging experiments (with and without tertiary air). All test were performed with air staging in the years 1995 and 1996. The aim of the research was to determine whether the co-combustion of waste materials will cause additional emission problems, as compared to combustible emissions from conventional air-staged fluidized bed combustion. Further, the aim was to study which large-volume components can be burned safely. One aim was to study the influence of fuel properties and combustion conditions ...
1998-12-31
UK PubMed Central (United Kingdom)
Heart failure has been singled out as an emerging epidemic, which could be the result of increased incidence and/or increased survival leading to increased prevalence. Knowledge of the responsibility...Full Text Available
2010-04-01
Increasing the Mobility of Dismounted Marines. Small Unit ...
Page 1. TECHNICAL REPORT 1988 October 2009 Increasing the Mobility of Dismounted Marines ... Increasing the Mobility of Dismounted Marines ...
2009-10-01
Thermal fatigue failure at the White Cliffs solar thermal power plant
Energy Technology Data Exchange (ETDEWEB)
The failure of receivers has been one of the main operating problems at the White Cliffs solar thermal power plant. This Technical Note reports the results of an initial investigation that identifies the cause as having been their thermal fatiguing of the tube walls. The fatigue appears to be caused by unstable heat transfer at vapor qualities below the point where critical heat flux is generally exceeded. Methods for avoiding this problem are tested.
1995-02-01
The nucleon axial charge in full lattice QCD
Energy Technology Data Exchange (ETDEWEB)
The nucleon axial charge is calculated as a function of the pion mass in full QCD. Using domain wall valence quarks and improved staggered sea quarks, we present the first calculation with pion masses as light as 354 MeV and volumes as large as (3.5 fm)3. We show that finite volume effects are small for our volumes and that a constrained fit based on finite volume chiral perturbation theory agrees with experiment within 5% statistical errors.
2005-10-13
UK PubMed Central (United Kingdom)
Streptococcus pyogenes is an important human pathogen and surface structures allow it to adhere to, colonize and invade the human host. Proteins containing leucine rich repeats (LRR)...Full Text Available
State-of-the-art technology for production of seamless tubes in zirconium and titanium alloys
International Nuclear Information System (INIS)
Zircaloy fabrication plant manufactures all the necessary Zr-2 components like fuel canning tubes, calandria tubes and other rod and sheet products. This plant is having a capacity of producing about 4 lakh nos. of PHWR fuel tubes per annum. These tubes are seamless, thin walled with close dimensional tolerances and stringent mechanical properties. The plant has established all the facilities required to produce these tubes with required quality.
Spin-up of He II in a cylindrical vessel of finite height
Energy Technology Data Exchange (ETDEWEB)
The spin-up problem of He II in a cylindrical container of infinite and finite height is considered on the basis of the Hall-Vinen-Bekarevich-Khalatnikov equations. The boundary conditions include the assumption of the generation of superfluid vorticity at the walls of the container. In the lowest order approximation with respect to viscosity, the problem is reduced to a Stefan problem for a single diffusion-type equation. Examples of solutions are given which show that the method used gives a good insight into the physical development of the spin-up flow.
1990-01-01
Energy Technology Data Exchange (ETDEWEB)
A phenomenological model of the heat transfer in direct injection diesel engines was developed. Utilizing the thermodynamic results of a combustion model as an input, the model is able to predict the temporal variation of the heat losses from the cylinder gas to the cylinder walls. Additionally, the division into isothermal combustion chamber subsurfaces allows the consideration of the spatial variation of the wall heat fluxes. The physical mechanisms such as flow dependent convection, heat radiation due to hot soot particles and isolation effects of deposited soot layers are described in detail. Thus the effects of these mechanisms on the overall heat transfer can be studied. The heat transfer model was verified successfully by the comparison to measured wall heat fluxes in a single-cylinder direct injection diesel engine. It is shown that the effects of engine speed and load, turbocharging and soot deposition can be ...
2000-07-01
Particle simulation of edge pedestal formation and plasma rotation dynamics
International Nuclear Information System (INIS)
Gyrokinetic particle simulation of edge pedestal formation and plasma rotation dynamics will be presented, and compared with experimental observations. Realistic tokamak edge geometry is used which include separatrix/X-point and material wall from EFIT g-eqdsk data. In order to handle adequately the spatially inhomogeneous electric potential in the scrape-off region, the full-f electron technique is used, in addition to the full-f ions. Monte Carlo neutral particles with wall recycling coefficient will be included self-consistently with the plasma kinetics. Ion-ion Coulomb collisions will be particle, momentum and energy conserving. Energy source for the pedestal and scrape-off plasmas is the heat flow from the core plasma, and the particle source is the ionization of the neutral atoms which are either wall recycled and/or gas puffed. The simulation will be self-consistent with the first principles nonlinear neoclassical ...
2007-03-26
PIV measurements of flow structures in a spray dryer
DEFF Research Database (Denmark)
Stereoscopic Particle Image Velocimetry (PIV) measurements are made in horizontal planes in a simplified scale model of a spray dryer using water as fluid. The sample rate was sufficient to resolve phenomena at lower frequencies. Data reveal asymmetric velocity fields in both mean fields and dynamics. Data were analysed using Proper Orthogonal Decomposition (POD). An important periodic event is an elongation of the jet core cross section that results in a downstream displacement of the jet towards the chamber wall.
2011-01-01
International Nuclear Information System (INIS)
Full text of publication follows: As the coolant experiences no phase change in the core, SCWRs, unlike LWRs, cannot use design criteria based on the critical heat flux concept. The commonly accepted practice in SCWRs is to specify cladding temperature limits that must be met during transient and accident events. Therefore for the design of the SCWR, it is very important to predict the heat transfer coefficient to the supercritical water coolant with great accuracy. Our recent study focuses on the critical issue of measuring heat transfer to supercritical water at prototypical SCWR conditions and to develop the tools to predict the SCWR thermal behavior. A heat transfer test loop using a surrogate fluids, CO_2, is under construction. The reason of using CO_2 instead of water is that (i) valuable insight of the physical phenomena can be obtained with this fluid, and (ii) some existing facilities already used surrogate fluids, which in general have lower critical pressure and ...
2005-10-02
We present a high-statistics calculation of nucleon electromagnetic form factors in N{sub f}=2+1 lattice QCD using domain wall quarks on fine lattices, to attain a new level of precision in systematic and statistical errors. Our calculations use 32{sup 3}x64 lattices with lattice spacing a=0.084 fm for pion masses of 297, 355, and 403 MeV, and we perform an overdetermined analysis using on the order of 3600 to 7000 measurements to calculate nucleon electric and magnetic form factors up to Q{sup 2{approx_equal}}1.05 GeV{sup 2}. Results are shown to be consistent with those obtained using valence domain wall quarks with improved staggered sea quarks, and using coarse domain wall lattices. We determine the isovector Dirac radius r{sub 1}{sup v}, Pauli radius r{sub 2}{sup v} and anomalous magnetic moment {kappa}{sub v}. We also determine connected contributions to the corresponding isoscalar observables. We extrapolate these ...
2010-02-01
Loughborough set for bumper weekend at BUCS finals
...who trains at the University, lines up in the pole vault alongside Steve Lewis in the men's competition, who also trains at the Loughborough High performance Athletics Centre. Loughborough alumni Victoria Barr, Hayley Jones, Lee McConnell and Kim Wall are all in the British women's 4x400m relay ...
Japan: Toshiba in talks to buy Westinghouse stake: report
... Westinghouse Electric is already majority owned by Toshiba Corp the maker of flash memory chips, laptops, nuclear reactors and rice cookers and Shaw Group. A deal could erase any U.S. ownership of Westinghouse, the Wall Street Journal said. Shaw partnered with Toshiba, and another Japanese company to buy Westinghouse from British Nuclear Fuels PLC for $5.4 billion five years ago, the paper ...
Impact of the ENDF/B-VI Cross Section on the RPV Fluence Determination
Energy Technology Data Exchange (ETDEWEB)
The calculations with the broad-group cross-section library Bugle-96, and atom displacement (dpa) cross sections for iron, both derived from ENDF/B-VI data, result in higher calculated fast neutron fluxes, better agreement of calculations with radiometric dosimeter measurements, and significantly slower dpa rate attenuation through pressure vessel walls relative to the results with their predecessors: the Sailor library and ASTM iron dpa cross sections.
1999-09-12
Energy Technology Data Exchange (ETDEWEB)
Characteristics of pressure drop and heat transfer have been investigated for a lithium single-phase flow and a helium-lithium two-phase flow in a horizontal conducting circular channel in the presence of a uniform transverse magnetic field up to 1.4 T as related to the lithium cooling for magnetic-confinement fusion reactors. By the application of the magnetic field to the lithium single-phase flow, remarkable heat transfer enhancement has been observed at the top wall due to the suppression of the mixed convection occurring in the low Peclet number range, while appreciable heat transfer deterioration appeared in the high Peclet number range. It has been confirmed that the helium-lithium two-phase flow can reduce the high magnetohydrodynamic (MHD) pressure drop in a lithium single-phase flow, and it can provide much better heat transfer performance than that in a helium single-phase flow. In the presence of the magnetic field, heat transfer coefficient drastically ...
1998-09-01
UK PubMed Central (United Kingdom)
BackgroundCotton fiber development undergoes rapid and dynamic changes in a single cell type, from fiber initiation, elongation, primary and secondary wall biosynthesis, to fiber...Full Text Available
2009-01-01
Evaluations of half-bead weld repair procedures with thick-wall pressure vessels
The results of research on the evaluation of the half-bead weld repair method for use on nuclear reactor components are reviewed from data obtained on thick-section test pieces and intermediate-size pressure vessels. Material properties, the magnitude of residual stresses and the structural behavior of flawed pressure vessels are being obtained to determine the adequacy of the weld repair method for application in thick-section components.
1978-01-01
International Nuclear Information System (INIS)
Male rats were injected intravenously for 15 min with physiological saline (as control) (0.05 #mu#g/kg/min) or norepinephrine (NE) (0.1 #mu#g/kg/min) followed by 740 kBq of MIBG. Rats were injected for more 30 min (early stage group) and for more 4 hr (late stage group) with physiological saline or NE. Five MBq of "9"9"mTc-tetrofosmin (TF) was administered instead of MIBG in another group. The heart was isolated and uptake of MIBG or TF of right ventricle, apex, and left ventricle (divided into 8 parts) was measured. In control group, MIBG uptake of apex was significantly lower than that of lateral wall in both early and late groups. In NE group, MIBG uptake showed a tendency to decrease in both early and late groups. Compared with control group, the uptake of anterior wall in late group decreased significantly at NE 0.1 #mu#/kg/min. The TF uptake in control group was not different in each part. In NE group, the TF uptake of right ventricle ...
1998-06-01
Energy Technology Data Exchange (ETDEWEB)
Between October 1990 and March 1991, 8 patients with cystic lesions in the region of the posterior bladder wall, the seminal vesicles and the prostate were examined by MRI. In all cases there was accurate characterisation of the lesion and of its anatomy. In 3 patients with abnormalities in the retrovesical space there was very good agreement with the operative findings. 4 patients were treated conservatively. In these patients there was good agreement with the findings on cystoscopy, CT and sonography. (orig.).
1992-07-01
Chamber technology concepts for inertial fusion energy: Three recent examples
Energy Technology Data Exchange (ETDEWEB)
The most serious challenges in the design of chambers for inertial fusion energy (IFE) are 1) protecting the first wall from fusion energy pulses on the order of several hundred megajoules released in the form of x rays, target debris, and high energy neutrons, and 2) operating the chamber at a pulse repetition rate of 5-10 Hz (i.e., re-establishing, the wall protection and chamber conditions needed for beam propagation to the target between pulses). In meeting these challenges, designers have capitalized on the ability to separate the fusion burn physics from the geometry and environment of the fusion chamber. Most recent conceptual designs use gases or flowing liquids inside the chamber. Thin liquid layers of molten salt or metal and low pressure, high-Z gases can protect the first wall from x rays and target debris, while thick liquid layers have the added benefit of protecting structures from fusion neutrons thereby ...
1997-02-27
UK PubMed Central (United Kingdom)
Chondrosarcomas are the most frequently occurring primary malignant chest wall tumors. Furthermore, the lungs serve as the most frequent sites for metastases. Pulmonary metastases from sarcomas usually...Full Text Available
Calculation method for microwave pyramidal horn radiators with curvilinear generatrix
British Library Electronic Table of Contents (United Kingdom)
Calculation method for pyramidal horn radiators (PHR) with curvilinear generatrix has been developed on the basis of the theory of waveguide tapers. This method makes it possible to reduce the value of spurious reflection coefficients and transformation of the principal wave into waves of higher order modes by forming generatrixes of walls with specific curvilinearity.
2008-01-01
Assessment of left ventricular wall motion by optional multiple long-axial gated blood pool SPECT
International Nuclear Information System (INIS)
Optional multiple long-axial gated blood pool SPECT images were prepared for the purpose of stereoscopic and quantitative imaging of left ventricular wall motion (LVWM). Sixteen patients with ischemic heart disease and 8 healthy subjects were imaged in 32 views in the 360 degrees position after iv injection of 740 MBq of Tc-99m-labeled human serum albumin D. The R-R interval was divided into 16. After preparing conventional oblique images, long-axial images were prepared. Shortening rate of left ventricular wall was calculated in 5 segments of the apex and base of the left ventricle. An average shortening rate in each segment was graded with a score from a minimum of 0 to a maximum of 40% or more. In the normal group, shortening rate in each segment, except for the base of the septal region, exceeded 40%. In the group of ischemic heart disease, radial shortening was capable of visualizing the degree and extent of the whole LVWM abnormality. ...
1991-01-01
A Monte Carlo model for predicting water quality in mine pit lakes
Energy Technology Data Exchange (ETDEWEB)
A model has been developed to predict the chemical composition of lakes that form in pyrite-bearing open-pit mines. Pyrite oxidation in wall rock releases sulfuric acid and metals, which mix with ground waters in the lake. Aqueous metal concentrations are calculated using MINTEQA2.
1995-12-01
A HELICAL MAGNET DESIGN FOR RHIC.
Energy Technology Data Exchange (ETDEWEB)
Helical dipole magnets are required in a project for the Relativistic Heavy Ion Collider (RHIC) to control and preserve the beam polarization in order to allow the collision of polarized proton beams. Specifications are for low current superconducting magnets with a 100 mm coil aperture and a 4 Tesla field in which the field rotates 360 degrees over a distance of 2.4 meters. A magnet meeting the requirements has been developed that uses a small diameter cable wound into helical grooves machined into a thick-walled aluminum cylinder.
1997-05-12
60 million dollars for electric cars; 60 Millionen Dollar fuer die Formel-EE
Energy Technology Data Exchange (ETDEWEB)
Rising oil prices are a problem for the motor car industry. Now, an ambitious project has been launched in California which may become a serious competitor to gasoline and diesel engines: The Tesla Roadster, which is fuelled from simple wall sockets. (orig.)
2007-07-01
Contaminant transport in fracture networks with heterogeneous rock matrices. The Picnic code
Energy Technology Data Exchange (ETDEWEB)
In the context of safety assessment of radioactive waste repositories, complex radionuclide transport models covering key safety-relevant processes play a major role. In recent Swiss safety assessments, such as Kristallin-I, an important drawback was the limitation in geosphere modelling capability to account for geosphere heterogeneities. In marked contrast to this limitation in modelling capabilities, great effort has been put into investigating the heterogeneity of the geosphere as it impacts on hydrology. Structural geological methods have been used to look at the geometry of the flow paths on a small scale and the diffusion and sorption properties of different rock materials have been investigated. This huge amount of information could however be only partially applied in geosphere transport modelling. To make use of these investigations the 'PICNIC project' was established as a joint cooperation of PSI/Nagra and QuantiSci to provide a new geosphere transport ...
2001-02-01
Improved Usability of Locomotion Devices Using Human ...
... increasing photorealism. Furthermore, developments in audio technology continue to increase the spatial awareness of users in VEs. ...
2009-03-01
Energy Technology Data Exchange (ETDEWEB)
This report documents the concluding efforts at the Engineering Sciences Laboratory of TRW on two specific areas of current research activity within the more general context of proposed lean-burn operation of Otto-cycle-type automotive engines. These areas are: (1) achievement of knock-free performance, both under available fuels and current compression ratios and also under higher-octane fuels (e.g., alcohols) and higher-compression-ratio design (for greater thermal efficiency); and (2) identification of counterstrategies for two-wall (crevice-type) quenching of flame propagation, a phenomenon now widely acknowledged to be the major source of unburned-hydrocarbon emissions exhausted from homogeneous-charge cyclinders. There are certainly other highly active areas of research in Otto-cycle engines, such as turbocharging, ignition devices, and valve design, but the two above-cited topics were the topics of this project.
1984-01-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: To visualise the vessel wall of the descending thoracic aorta using magnetic resonance imaging. To evaluate the diagnostic potential of tailored T{sub 1}-weighted sequences with contrast enhancement to assess systemic atherosclerotic disease. Methods: This study was performed on a clinical 1.5 Tesla scanner using a gradient strength of 30 mT/m and the phased array spine coil. A cadaver was examined to optimise a magnetic resonance imaging (MRI) protocol to evaluate atherosclerotic aortic wall disease. The acquired MR images were compared to gross specimens and histology. Subsequently seven patients who had undergone transesophageal ultrasound (TEU) with detailed assessment of the descending thoracic aorta were examined with MRI. The optimised protocol included untriggered and fat suppressed T{sub 2}-weighted turbo spin echo sequences and ECG-triggered and fat suppressed T{sub 1}-weighted spin echo sequences before and after iv ...
2002-05-01
International Nuclear Information System (INIS)
Natural convection flow is established in KMRR (Korea Multi-Purpose Research Reactor) reflector tank at the loss of reflector circulator. To simulate the reflector tank natural convection flow with high temperatures at the inner shell and bottom plate due to nuclear heating, experimental and numerical studies in an open cavity with 'L' type heated wall made by the combination of a vertical and horizontal plate were performed. It was confirmed through these studies that the heat transfer rates were highest at the lower region of the vertical plate and the inlet region of horizontal plate and comparatively high at the middle portion of both plates. The heat transfer rate distribution of this trend shows a desirable trend for the effective natural convection cooling of KMRR reflector tank. It was also confirmed that the average Nusselts numbers at the 'L' type heated wall were lower than those obtained from the existing natural convection heat ...
1991-10-26
Turbulent heat transfer augmentation and friction in periodic fully developed channel flows
Energy Technology Data Exchange (ETDEWEB)
Measurements are presented of the distribution of average friction factors (f) as well as local and average ({ovr Nu}) heat transfer coefficients for fully developed channel flows with two rib-roughened opposite walls. The temperature measurements were made by using both a laser holographic interferometer and thermocouples. In addition, the reattachment length was determined by flow visualization. The Reynolds number (Re) was varied from 5.0 {times} 10{sup 3} to 5.4 {times} 10{sup 4}; the rib pitch-to-height ratios (Pi/H) were 10, 15, 20; and the rib height-to-hydraulic diameter ratios (H/De) were 0.063, 0.081, and 0.106. The detailed results allowed the peaks of heat transfer augmentation and the regions susceptible to hot spots to be located and allowed the relative contribution of the rib surface and the channel wall to the heat transfer augmentation to be determined. Moreover, relative to a smooth duct, the enhancement of both {ovr Nu} and ...
1992-02-01
The forming process of magnesium alloy for Japanese home electric components
Energy Technology Data Exchange (ETDEWEB)
Magnesium alloys have replaced resins as a material for the components of electronic products such as cell phone and notebook personal computer mainly, because of their lightness and rigidity. Thin walls, a complicated shape, and high appearance quality are all needed in the external parts. Die-casting and injection molding are the main method of manufacturing magnesium alloy parts. The optimal cast conditions and mold design have been investigated in order that a few defects such as surface cracks and mold cavities in casting parts would be reduced. Instead of cast, plastic forming technologies such as warm drawing and hot forging have been developed to form thinner walls and less defects. Plastic formability of magnesium alloy in hot working is dependent on a grain size of material. The material with fine grains has advantage of being formed at high strain rate. The characteristics of forming processes of magnesium parts for Japanese home ...
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
Possible threats against the leak tightness of the reactor containments, due to pipe whips from hypothetical pipe ruptures in the steam- and feedwater systems, have been investigated for Forsmark 3/Oskarshamn 3, Ringhals 1, Oskarshamn 1 and Barsebaeck 2/Oskarshamn 2. Based on available drawings, such as installation drawings and isometric views of pipes, the pipe systems have been put together in new drawings with their bracing supports and containment walls. This inventory shows that pipe whips can occur on a number of places on the containments walls after hypothetical pipe ruptures in the steam- and main feedwater systems. In order to find out whether these pipe whips are real threats against the leak tightness, further analysis needs to be made but are out of the scope of this investigation.
2001-03-01
Spectral dependence of ultrasonic attenuation for hydrided Zr-2.5%Nb Alloy
International Nuclear Information System (INIS)
The cold-worked Zr-2.5%Nb alloy is used as material for the pressure tubes in CANDU nuclear reactors. During the service life in reactor, diffusion of hydrogen and/or deuterium in the pressure tubes wall occur. Below a certain temperature, a stable hydride of zirconium is formed, as a brittle phase which can lead to catastrophic failures. For this reason, it is very important to be able to investigate the hydrogen effect on the micro structural properties of zirconium alloys. In the present paper a non-destructive testing technique is used, known as ultrasonic spectral analysis. When an ultrasonic signal traverses a medium, the frequency components associated with the input signal are altered. By frequency analysing the reflected signals, it is possible to study and compare the material properties. The two major parameters measured in ultrasonic spectroscopy are the attenuation and the velocity of the waves. Attenuation is determined by the energy losses in ...
2009-10-12
Simulation of electromechanical and thermomechanical loads on first wall mock-ups
International Nuclear Information System (INIS)
In order to study the boundary conditions for the occurrence of ratcheting, a testing rig was erected. In this rig, small-scale mock-ups of the first wall were tested under mechanical conditions similar to those expected during disruptions. These mock-ups were made of stainless steel AISI 316. They were heated on the surface and water cooled from inside. Disruption forces were simulated by a high-speed hydraulic bending system by impact loads. The mock-ups were heated by a high-frequency generator and cooled by water through two cooling channels.In addition to the experimental work, simplified analytical analysis and numerical calculations were carried out using the finite element program ABAQUS. In these calculations, the temperature and stress fields in the mock-ups were investigated and the influence of the different constitutive equations was studied.The experimental results confirm the ratcheting behaviour predicted by the calculations. It has been ...
Simple and low cost biosensor based on screen-printed electrode for sensitive detection of some alkylphenols was developed, by entrapment of HRP in a nanocomposite gel based on single-walled carbon nanotubes (SWCNTs) and 1-butyl-3-methylimidazolium hexafluorophosphate ([BMIM][PF(6)]) ionic liquid. Raman and FTIR spectroscopy, CV and EIS studies demonstrate the interaction between SWCNTs and ionic liquid. The nanocomposite gel, SWCNT-[BMIM][PF(6)] provides to the modified sensor a considerable enhanced electrocatalytic activity toward hydrogen peroxide reduction. The HRP based biosensor exhibits high sensitivity and good stability, allowing a detection of the alkylphenols at an applied potential of -0.2V vs. Ag/AgCl, in linear range from 5.5 to 97.7?M for 4-t-octylphenol and respectively, between 5.5 and 140?M for 4-n-nonylphenol, with a response time of about 5s. The detection limit was 1.1?M for 4-t-octylphenol, and respectively 0.4?M for 4-n-nonylphenol (S/N=3). ...
2011-07-19
Second law analysis of compressible flow through a diffuser subjected to constant heat flux at wall
International Nuclear Information System (INIS)
Entropy generation is equivalent to destruction of available work (exergy). The useful energy is destroyed due to the intrinsic irreversibility associated within thermodynamic systems. Exergy analysis can be used as an effective basis for the development and improvement of systems design not only in the overall perspective but also in the individual component level. Second law analysis provides a useful tool to identify the irreversibility in any thermal system. This study presents the investigation of local and total entropy generation in compressible flow through a diffuser. Air is used as the fluid. Uniform heat flux boundary condition is applied at the wall. Two dimensional solution of velocity and temperature fields are obtained using the CFD code FLUENT. Distribution of entropy generation rate is investigated throughout the volume of the fluid as it flows through the diffuser. Regions of high entropy generation in the diffuser have been predicted. The angle ...
2010-12-01
Reliability analysis of pipe whip impacts
Energy Technology Data Exchange (ETDEWEB)
A probability-based approach is presented as the integration of probabilistic methods and deterministic modelling based on the finite element method. An existing finite element software package was linked to an existing probabilistic package to analyse the complex mechanics that occur during the transient non-linear analysis of impact problems. This methodology is applied to a pipe whip analysis of a group-distribution-header, which results from a guillotine break, and subsequent impact with the adjacent building wall; this is a postulated accident for the Ignalina Nuclear Power Plant RBMK-1500 reactors. The uncertainties of material properties, component geometry data and loads were taken into consideration. The probabilities of failure of the impacted header and of the header support-wall were estimated given uncertainties in material properties, geometrical parameters and loading. The software ProFES was used for the probabilistic analysis ...
2005-08-01
International Nuclear Information System (INIS)
A critical issues study of a symmetric illumination, direct drive laser fusion reactor called SIRIUS has been conducted. In particular, the uniformity requirements for direct drive targets have been assessed and it is shown that respectable gains (more than 60) could be obtained at modest (2MJ) KrF laser energies. Previous ICF cavity designs have been examined for use in a symmetric illumination geometry and features from several designs have been combined into a dry wall cavity design with a radius of 8 meters. Neutronic and photonic analysis shows that the present SIRIUS cavity design can breed sufficient tritium (breeding ratio = 1.17) even with 32 laser ports penetrating the cavity. However, it was found that there are a few critical issues that remain to be solved before a self-consistent reactor design could be initiated. Radiation damage to final optics, thermal performance of SiC tiles on the SIRIUS cavity wall, and performance of ...
1984-01-01
Polarization of electron cyclotron emission spectra in LHD
Energy Technology Data Exchange (ETDEWEB)
Electron cyclotron emission (ECE) can be used to determine the electron temperature profile in magnetized plasmas. The complex structure of the magnetic field configuration in the Large Helical Device (LHD), which has a large shear, complicates the analysis of the ECE spectrum. In a sheared magnetic field the propagation of X and O-mode polarization through the plasma are coupled, causing mode conversion and polarization rotation. Mode scrambling is also caused by wall reflections. In this report, this mode conversion in LHD is numerically analyzed. It was found that at low density mode conversion scrambles the ECE spectra. However, at higher density (n{sub eo} > 1.0{center_dot}10{sup 19} m{sup -3}) the polarization mode is found to rotate with the sheared magnetic field, yielding only a negligible mode conversion. Wall reflections are found to depolarize the ECE spectrum. Notwithstanding the LHD magnetic configuration, it is shown that ...
1999-07-01
Piping response testing associated with pipe rupture
Energy Technology Data Exchange (ETDEWEB)
EPRI has sponsored an experimental program in the pipe whip impact and pipe rupture and depressurization areas. Sixteen pipe whip tests were performed with 3 in Schedule 80 (or 10) carbon steel pipes impacting on rigid target or concrete slab. The major testing parameters include distance, impact location, pipe rupture location, and concrete slab thickness and strength. The piping crushing at impact correlates with impact force and target response behavior. Conservatism was established by comparing measured and calculated impact forces. The pipe rupture and depressurization tests were carried out using 6 in stainless steel and carbon steel pipes under either PWR or BWR fluid conditions. These tests are of axial crack with initial machined-in surface flaw. It was found that pipe rupture would occur only if a long unstable through-wall crack was embedded in a sufficiently long unstable part-through crack (in the pipe wall). All other flaw ...
1985-11-01
Energy Technology Data Exchange (ETDEWEB)
A permeable reactive mixture has been developed using low cost, readily available materials that is capable of providing effective, long-term phosphorous treatment in areas impacted by on-land wastewater disposal. The reactive mixture creates a geochemical environment suitable for P-attenuation by both adsorption and precipitation reactions. Potential benefits include significant reductions in phosphorous loading to receiving groundwater and surface water systems, and the accumulation of P-mass in a finite and accessible volume of material. The mixture may be applied as a component within surface treatment systems or in subsurface applications such as horizontal or vertical permeable reactive walls. The mixture averaged > 90% treatment efficiency over 3.6 years of continuous-flow laboratory column experiments. The mixture was further evaluated at the pilot-scale to treat municipal wastewater, and the field-scale to treat a well-characterized septic system plume ...
1997-12-31
Investigation of the impact of electricity rate and mix on optimum green building design
Energy Technology Data Exchange (ETDEWEB)
The basic principle of the green building philosophy is to design buildings that consider environmental performance. Residential and commercial buildings in Canada consume about 30 per cent of the total secondary energy use and are responsible for approximately 29 per cent of carbon dioxide equivalent greenhouse gas emissions and many other wastes. An optimization model was developed which minimizes life cycle cost and life cycle environmental impact. The model distinguishes different energy sources and incorporates their impacts, such as resource depletion, global warming and acidification. The model also considers design variables such as window type, orientation, building orientation, window-to-wall ratio, wall type and roof type. The model can be used to identify optimum green building designs for given conditions. The model uses expanded cumulative exergy consumption as the indicator for life cycle environmental performance. As such, it ...
2004-07-01
Inspection of PFR steam generators
International Nuclear Information System (INIS)
The inspection of PFR evaporator tubing, superheater and reheater tubing, and tube plate examinations, are described. Ferritic steel U tubes in the evaporator have been examined by an eddy current system operating at 400 kHz using flexible rotating probes. Surface defects as shallow as 0.1 mm can be detected and sized in the range 0.1 to 0.5 mm deep. An ultrasonic method is under development for wall thickness. Special test coil probes have been developed for examination of the type 316 stainless steel superheater and reheater tubing. Crack-life defects in the bore are detectable at approximately 10% wall thickness and 20% on the outside diameter. Tube plate examinations from the tube holes, have been conducted using eddy current probes which identify surface breaking cracks in the holes. For detecting curtain cracks between tube plate holes, ultrasonic compression wave probes have been used. (U.K.).
1976-03-09
Granular flow considerations in the design of a cascade solid breeder reaction chamber
International Nuclear Information System (INIS)
Both horizontally and vertically oriented rotating chambers with granular material held on the inner surface by centrifugal action are examined. Modifications to the condition for controlled quasi-static flow on an incline plane, phi/sub w/ < #alpha# < phi/sub r/, where phi/sub w/ is the wall friction angle, #alpha# is the angle of inclination of the plane, and phi/sub r/ is the drained angle of repose of the material are examined for the case of horizontal and vertical surfaces of revolution. Allowed included half angles for horizontally oriented chambers are likely to be in the range of 30"0 +- 10"0 for ceramic particles and metal surfaces. For vertical orientations the maximum half-angle of the top cone is slightly less than the wall friction angle phi/sub w/ while the lower portion can have a half angle as large as (90"0 - phi/sub w). Percolation of fines through shearing granular solids is briefly discussed and recommended ...
1970-05-01
Focal lesions in external auditory canal: computed tomography images
International Nuclear Information System (INIS)
To analyze and review the most common focal lesions of the external auditory canal (EAC), describing the computed tomography (CT) findings. The CT images of EAC were reviewed in a series of 167 patients. Abnormal findings were recorded in 13 cases. The CT images were correlated with otoscopic and/or intraoperative findings. There were four cases of osteoma (one located outside the EAC); all of which were treated surgically, as was the one case of exostosis. Six patients presented debris in EAC, coinciding with clinical evidence of external otitis. There were two cholesteatomas derived from EAC, one of them secondary to survery to treat osteoma. On patient was diagnosed as having a basal cell carcinoma of the ear, extending to EAC, but refused to undergo surgery. Five patients presented small triangular laminae of dense bone arising from the upper wall of the EAC which were defined as abnormal variants of the fusion of the temporal squamous epithelium to the ...
Diagnostic value of MRI for hepatic hilar cholangiocarcinoma
International Nuclear Information System (INIS)
Objective: To investigate the value of MRI in the diagnosis of hepatic hilar cholangiocarcinoma. Methods: Sixty-four patients with hepatic hilar cholangiocarcinomas confirmed by surgery or pathology underwent MRI using a 1.5-T superconductive MR system including conventional unenhanced MRI, MRCP and dynamic contrast-enhanced MRI with Gd-DTPA. Results: Dilatation of the intrahepatic biliary tree with narrowing, occlusion or filling defects in the hepatic hilar bile ducts was noted in all 64 cases. Unenhanced MR[ showed T_1- and T_2-hyperintense hilar masses in 42 patients and was normal in the remaining 22 patients. The hilar masses demonstrated slow, progressive and delayed enhancement patterns. There was enhancement of the thickened bile duct wall with luminal narrowing in the 22 patients without hilar masses. Conclusion: The characteristic MRI findings of enhancing hepatic hilar mass and bile duct wall thickening together with MRCP are ...
2010-02-01
Cracking of Alloy 800 tubing in superheated steam in a solar receiver
Energy Technology Data Exchange (ETDEWEB)
The solar central receiver at the Barstow Pilot Plant is a once-through steam boiler consisting of vertical arrays of Alloy 800 tubes. Water/steam leaks associated with tube bends near the receiver outlet were observed after 16 service months. The leaks resulted from through-wall cracks localized in the crown of tube bends operating in the temperature range from 550 to 650/sup 0/C. Initiation occurred on the ID (steam side) of the tube and propagated transgranular through the tube wall. Cracking was axial and circumferential; in general, the circumferential cracks were more severe than the axial cracks. Thick oxide layers showed on the ID of the receiver tubes; a 25-..mu..m thick oxide layer had formed on tubing which operated at 650/sup 0/C. In addition, an enhanced oxidation layer was observed along a narrow band in the crown of the tube. This band was up to five times thicker than the oxide elsewhere in the tube. All cracking was associated ...
1985-10-01
Corrosion of support materials
International Nuclear Information System (INIS)
Results from a heavily fouled 19 tube C-E model boiler test to investigate the potential for egg crate corrosion in aggressively fouled AVT chemistry are reported. Substantial support plate and egg crate corrosion was produced in this test. Carbon steel drilled support plates exhibited extensive denting which resulted in flow hole ligament cracking. Corrosion of the carbon steel egg crate, through-wall at areas of tube contact, resulted in denting of the Alloy 600 heat transfer tubes. Corrosion performance of the 409 stainless steel egg crate was improved compared to the carbon steel egg crate although localized through-wall corrosion was noted. The results from the above test and previously reported tests were compared based on the following simplifying assumptions: maximum dent size and/or corrosion penetrations utilized, average bulk water chloride concentrations, pilling bedworth ratios, pot and model boilers data are equivalent, heat flux ...
1985-03-01
Two types of evacuated tube solar collectors have been operated in space heating, cooling and domestic hot water heating systems in Colorado State University Solar House I. An experimental collector from Corning Glass Works supplied heat to the system from January 1977 through February 1978, and an experimental collector from Philips Research Laboratory, Aachen, which is currently in use, has been operating since August 1978. A flat absorber plate inside a single-walled glass tube is used in the Corning design, whereas heat is conducted through a single glass wall to an external heat exchanger plate in the Philips collector. In comparison with conventional flat-plate collectors, both types show reduced heat losses and improved efficiency. For space heating and hot water supply in winter, the solar delivery efficiency of the Corning collector ranged from 49% to 60% of the incident solar energy. The portion of the space heating and domestic hot ...
1979-01-01
Energy Technology Data Exchange (ETDEWEB)
Compact dielectric wall (DWA) accelerator technology is being developed at the Lawrence Livermore National Laboratory. The DWA accelerator uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. Its high electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The DWA concept can be applied to accelerate charge particle beams with any charge to mass ratio and energy. Based on the DWA system, a novel compact proton therapy accelerator is being developed. This proton therapy system will produce individual pulses that can be varied in intensity, energy and spot width. The system will be capable of being sited in a conventional linac vault and provide intensity modulated rotational therapy. The status of the developmental new technologies that make the compact system possible will be reviewed. These include, high ...
2009-06-17
Buffeting of a slender circular beam in axial turbulent flows
Energy Technology Data Exchange (ETDEWEB)
This paper deals with the buffeting of a slender, circular, flexible beam-rod in an axial turbulent flow. The principal excitation mechanisms are the turbulent wall pressure fluctuations and the motion-dependent (self-excited) aerodynamic force caused by the beam motion. On the assumption that the turbulent wall pressure fluctuations are independent of the beam motion, a linear forced-vibration model is used to determine the buffeting response of the beam and to investigate the length scale effects of turbulences on the beam buffeting. Transverse buffeting of the beam in an axial turbulent flow depends largely on the ratio of the longitudinal scale of the turbulences to the bending wavelength of the beam and on the ratio of the circumferential scale of the turbulences to the radius of the beam. The spectra and the mean square values of the buffeting displacement of the beam become vanishingly small, both when either of these ratios is very ...
1984-05-01
International Nuclear Information System (INIS)
In the case wherein nonlinear seismic response analyses are carried out, the response values vary due to the variations in materials and modeling. In this paper, nonlinear analyses of several random variables are carried out using: i. a conventional method; ii. a two-point estimation method (i. and ii. are simplified methods); and iii. Monte Carlo simulation (detailed method) to examine the variability of the response in the excessive nonlinear range for seismic responses of shear walls. The analyses are performed to a PWR-3 loop type reactor building which is one of the most typical reactor buildings in Japan. The variations are considered in specified compressive strength of concrete, concrete damping factor, shear wave velocity of soil and shapes of shear stress-strain relation curves of shear walls. As the results by the two simplified methods closely matched the Monte Carlo simulation results, the appropriateness for applying the ...
1993-08-15
A study of Two-Phase Flow Regime Maps in Vertical and Horizontal Pipes
Energy Technology Data Exchange (ETDEWEB)
A safety analysis code to design a pressurized water reactor and to obtain the licences including entire proprietary rights is under development in domestic research and development project. The purpose and scope of this report is to develop the flow regimes related models for inter-phase friction, wall frictions, wall heat transfer, and inter-phase heat and mass transfer in two-phase three-field equations. In order to choose choose the flow regime criteria, we have investigated various exiting best-estimate T/H codes in this chapter 2. They are the RELAP5-3D, TRAC-M, CATHARE, MARS codes. Around 500 references used in these codes have been collected and reviewed. Also we have investigated eleven papers in detail. In chapter 3, based on the selected flow regimes, the flow regime maps for a gas-liquid flow in horizontal and vertical tubes have decided including the mechanisms of flow regime transition regions. Conclusively, the process will be ...
2007-10-15
A Compact Linac for Proton Therapy Based on a Dielectric Wall Accelerator
Energy Technology Data Exchange (ETDEWEB)
A novel compact CT-guided intensity modulated proton radiotherapy (IMPT) system is described. The system is being designed to deliver fast IMPT so that larger target volumes and motion management can be accomplished. The system will be ideal for large and complex target volumes in young patients. The basis of the design is the dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL). The DWA uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system will produce individual pulses that can be varied in intensity, energy and spot width. The IMPT planning system will optimize delivery characteristics. The system will be capable of being sited in a conventional linac vault and provide intensity ...
2007-10-29
Energy Technology Data Exchange (ETDEWEB)
The atrial myocardium has been barely visible with thallium-201 myocardial scintigraphy. This is probably related to the difference in size, distance from anterior chest wall, and small coronary blood flow of the atrium, compared with the ventricle. We have encountered eight cases of visualization of the right atrial appendix (RAA). The RAA was identified from multiple projections in all cases and sometimes confirmed by radionuclide angiocardiography. Evidence derived from ECG, chest radiographs, and cardiac catheterization, indicated that the most important factor in the visualization might be the displacement of the RAA to a more anterior position.
1980-10-01
International Nuclear Information System (INIS)
The lateral bearing device is made of 7 lateral supports, each positioned to allow the displacement of the steam generator due to thermal or seismic effects. Each support includes a buffer plate that can be positioned on the steam generator using a position control assembly. This control assembly consists of a screw jack arrangement where the nut is fastened via an energy absorbing layer to a footplate that is fixed to the concrete wall of the steam generator enclosure. 4 figs.
1992-03-31
Topological Defects in the Moduli Sector of String Theory
We point out that the moduli sector of the $(2,2)$ string compactification with its nonperturbatively preserved non-compact symmetries is a fertile framework to study global topological defects, thus providing a natural source for the large scale structure formation. Based on the target space modular invariance of the nonperturbative superpotential of the four-dimensional N=1 supersymmetric string vacua, topologically stable stringy domain walls are found. They are supersymmetric solutions, thus saturating the Bogomolnyi bound. It is also shown that there are moduli sectors that allow for the global monopole-type and texture-type configurations whose radial stability is ensured by higher derivative terms.
1991-01-01
Thermal performance and design of a solid particle cavity receiver
Energy Technology Data Exchange (ETDEWEB)
A model for energy transport in a solid particle cavity receiver is developed and applied to the design and analysis of a receiver for the Central Receiver Test Facility (CRTF), Albuquerque, New Mexico. The model gives thermal performance results - including particle temperatures, cavity efficiencies, and wall temperatures - which directly affect the economic and technical feasibility of a solid particle receiver. In addition, design criteria relevant to the configuration of a solid particle cavity receiver are developed. Results for CRTF indicate that at design conditions particle temperatures will exceed 1200/sup 0/K with cavity efficiencies on the order of 75%.
1985-04-01
The reversed-field-pinch (RFP) fusion neutron source: A conceptual design
Energy Technology Data Exchange (ETDEWEB)
The conceptual design of an ohmically heated, reversed-field pinch (RFP) operating at /approximately/5-MW/m/sup 2/ steady-state DT fusion neutron wall loading and /approximately/124-MW total fusion power is presented. These results are useful in projecting the development of a cost effective, low input power (/approximately/206 MW) source of DT neutrons for large-volume (/approximately/10 m/sup 3/), high-fluence (3.4 MW yr/m/sup 2/) fusion nuclear materials and technology testing. 19 refs., 15 figs., 9 tabs.
1989-01-01
Energy Technology Data Exchange (ETDEWEB)
An analytical study of the ice-formation process associated with heat-conducting plates located perpendicularly to isothermally heated and cooled surfaces with some clearance is presented. It is proposed that the onset conditions, which describe whether the ice-volume fraction in a steady state is greater than or less than that without heat-conducting plates, are defined by the dimensionless distances between the heated/cooled walls and the heat-conducting plates. It is shown that the onset conditions are dependent on the pitch and the thickness of the heat-conducting plates and are less dependent on the thermal conductivity of the plates.
1994-07-01
The analysis of temperature distribution for surveillance Capsule in reactor vessel of YGN unit 1
International Nuclear Information System (INIS)
Generally, Hardening and irradiated brominating phenomena are occurred in the reactor vessel under operation conditions by atomic cavities and creation of impurity atoms which are led by high fast neutron flux. To assure the mechanical integrity of pressure vessel until the end of power plant life after monitoring the sample specimens on the vessel inside, a series of tests is performed over the retrieved surveillance capsule to examine the changes according to the plant operation in accordance with regulations. Monitoring surveillance capsules attached to neutron shield wall of outer core are consists of impact sample, tensile sample and temperature monitor
2007-05-10
The Preliminary GAMMA Code Thermal hydraulic Analysis for the Steady State of HTR-10 Initial Core
Energy Technology Data Exchange (ETDEWEB)
This report describes the preliminary thermalhydraulic analysis of HTR-10 steady state full power initial core to provide a benchmark calculation of VHTGR(Very High-Temperature Gas-Cooled Reactors) safety analysis code of GAMMA(GAs Multicomponent Mixture Analysis). The input data of GAMMA code are produced for the models of fluid block, wall block, radiation heat transfer and each component material properties in HTR-10 reactor. The temperature and flow distributions of HTR-10 steady state 10 MW{sub th} full power initial core are calculated by GAMMA code with boundary conditions of total reactor inlet flow rate of 4.32 kg/s, inlet temperature of 250 .deg. C, inlet pressure of 3 MPa, outlet pressure of 2.992 MPa and the fixed temperature at RCCS water cooling tube of 50 .deg C. The calculation results are compared with the measured solid material temperatures at 22 fixed instrumentation positions in HTR-10. The wall temperature distribution in ...
2006-07-15
International Nuclear Information System (INIS)
The objective of this study is to comprehend the basic structural characteristics of box shaped mixed structures proposed for a future nuclear reactor building structure. Specimens of reinforced concrete precast panel walls of the mixed structures were prepared using ultrahigh strength materials. Two bending shear tests were conducted with a parameter of the quantity of reinforcement bars. The results include: (1) Relationship of shear stress and the angle of the structure, and (2) Failure mode. (author)
1993-08-15
Roentgenological analysis of sternocostoclavicular hyperostosis by computed tomography
Energy Technology Data Exchange (ETDEWEB)
Roentgenological analysis of the anterior chest wall was performed in twenty six patients with sternocostoclavicular hyperostosis. Initial hyperostotic change was seen at the first costosternal junction with ventral protrusion. Hyperostosis gradually developed around the first ribs, and irregular hyperostotic changes were also seen along the costoclavicular ligaments. Even in the final stage, however, sternoclavicular joint spaces were well preserved. These findings suggest that sternocostoclavicular hyperostosis is a disorder initiated around the costal cartilage including the periosteum and perichondrium, and that arthritis is not a condition stemming from that disorder.
1989-01-01
Risk assessment for the SNR-300 reactor. Earthquake hazard emanating from reactor component failure
International Nuclear Information System (INIS)
The risk analysis was carried out in consideration of conditions prevailing at the Kalkar site analogous to the investigations in phase A of DRS (German Reactor Study). Earthquake design loads include the probabilities of upper deviations of the site intensities to be expected. The calculations of dynamic loads for select buildings are made using models and computational methods. Component analyses were performed analogous to DRS for the supports of large components, supports of the roof construction of the reactor building taking into account support reserves due to plastic work capacity, wall disks in steam generator buildings and switchboard plant buildings. (DG).
Regenerative zinc/air and zinc/ferricyanide batteries for stationary power applications
Energy Technology Data Exchange (ETDEWEB)
The authors report a novel configuration for a zinc-particle, packed-bed anode in which an open structure of high hydraulic permeability is maintained indefinitely in a cell with closely spaced walls by the formation of particle bridges and associated gaps. The configuration minimizes electrolyte pumping costs, allows rapid refueling and partial recharge, and provides for 100% zinc consumption. This approach benefits zinc/air fuel batteries by allowing nearly continuous operation and fuel recycle without commercial infrastructure; it benefits Zn/[Fe(CN){sub 6}]{sup {minus}3} batteries by eliminating shape-change and polarization problems found with planar anodes.
1994-05-01
International Nuclear Information System (INIS)
Polymerizing effects of high energy radiation has been found suitable for preparation of wood-polymer composites. In the present work after evaluating polymer products that have been obtained by irradiation method, wood-polymer composites have been prepared by in situ polymerization of vinyl acetate, acrylic acid and acrylic acid/styrene mixture using two samples of Iranian hardwoods, Beech and Hornbeam. These woods and their composites have been tested for their physical and mechanical properties. The results have shown that chemical bonding between polymer and the cell wall component lead to better strength properties in the composites. (author).
1992-09-01
Predictions of convective losses from a solar cavity receiver
Convective losses arising from buoyancy driven flow were calculated for a two-dimensional model simulating a solar cavity receiver. The TEMPEST code, capable of fully three-dimensional coupled thermal-hydraulic transient calculations, was used for the simulation. Predicted velocity and temperature results for a 2.59 m deep by 2.88 m high rectangular cavity with an aperture opening of 1.72 m were used to determine convective losses for prescribed interior wall temperatures and cavity orientation. Velocity vector and temperature isotherm plots were used to analyze flow characteristics.
1979-12-01
Phytic acid doped nanoparticles for green anticorrosion coatings
British Library Electronic Table of Contents (United Kingdom)
In this paper, an environmentally friendly metal corrosion inhibitor, phytic acid, was assembled into the walls of silica nanoparticles via layer-by-layer self-assembly technique (LbL) with poly(allylamine hydrochloride). Such functionalized nanoparticles were uniformly distributed into sol-gel films for metal anticorrosion. The films showed very pronounced and lasting protective efficiency in concentrated salt aqueous solutions as indicated by electrochemical impedance spectroscopy (EIS) measurement. These results may provide a new route for the preparation of environment-friendly anticorrosion coatings.
2010-01-01
Peristaltic flow of a couple stress fluid in an annulus: Application of an endoscope
This paper discusses the influence of an endoscope on the peristaltic flow of a couple stress fluid in an annulus under a zero Reynolds number and long wavelength approximation. The inner tube is uniform, rigid, while the outer tube has a sinusoidal wave traveling down its wall. Analytical expressions for the axial velocity, stream function and axial pressure gradient are established. The flow is investigated in a wave frame of reference moving with the velocity of the wave. Numerical calculations are carried out for the pressure rise, frictional forces and trapping. The features of the flow characteristics are analyzed by plotting graphs and discussed in detail.
2008-04-01
Ozone removal by green building materials
Energy Technology Data Exchange (ETDEWEB)
Interest in finding out passive ways to keep the variation in the indoor climate within the comfort zone is gaining in popularity. One possible solution is the use of the moisture-buffering property of materials. In this study, the effects of the ventilation system and moisture-buffering properties of the building fabric on the stability of the indoor temperature and humidity are analysed by means of long-term field measurements. Indoor climate measurements were carried out in 170 detached houses (248 rooms). Temperature and relative humidity were measured continuously in bedrooms and living rooms at one-hour intervals over a one-year period. In general, it may be concluded that in this study, the ventilation had a greater effect on the indoor climate than the properties of the building fabric. The dampening effect of hygroscopic materials was remarkably less in the field measurements than it was in simulations in different studies. This indicates that completely non-hygroscopic and ...
2009-08-15
Nippon Kokan technical report, No. 108, July 1985
Energy Technology Data Exchange (ETDEWEB)
Contents include: countermeasures to save energy of sintering plant and future plans in fukuyama works; improvement of surface quality of continuous-casting slab; development of direct quenching and tempering type HT80 steel with good weldability; numerical analysis of fluid flow in a geothermal reservoir; the finite-element calculation of turbulent flow using the universal law of the wall; development of PC 4 dual fuel engine; design of industrialized housing; Computer-aided Navigation system (CANSY); and new production control system in Fukuyama Works.
1985-01-01
NIST {sup 222}Rn emission standards
Energy Technology Data Exchange (ETDEWEB)
NIST radon standards are hermetically sealed polyethylene capsules filled with {sup 226}Ra solution. Recently, four new series of standards with activities 5, 50, 500, and 5000Bq were prepared. The measured emanation fraction agrees with a calculation that accounts for the radon accumulated inside the polyethylene walls of the capsule. Obtained solubility of radon in polyethylene is approximately 45 of the solubility of radon in water. The radon diffusion coefficient in low-density polyethylene is 7.2x10{sup -8}cm{sup 2}/s.
2006-10-15
Mixed convection flow in a horizontal rectangular channel subjected to a horizontal thermal gradient
British Library Electronic Table of Contents (United Kingdom)
This paper deals with a mixed convection water flow in a horizontal rectangular duct, uniformly heated from one lateral vertical wall and thermally insulated elsewhere. The supplied heat flux induces a secondary flow, which structure is constituted of one longitudinal roll in the considered aspect ratio (??=?1.9), embedded into a return flow of possibly large stream wise extension (up to twenty channel heights). Such situation induces helicoidal trajectories for the fluid flow particles, which contributes to a heat transfer enhancement compared to purely forced convection flow.
2011-01-01
Mixed convection flow in a horizontal rectangular channel subjected to a horizontal thermal gradient
This paper deals with a mixed convection water flow in a horizontal rectangular duct, uniformly heated from one lateral vertical wall and thermally insulated elsewhere. The supplied heat flux induces a secondary flow, which structure is constituted of one longitudinal roll in the considered aspect ratio (? = 1.9), embedded into a return flow of possibly large stream wise extension (up to twenty channel heights). Such situation induces helicoidal trajectories for the fluid flow particles, which contributes to a heat transfer enhancement compared to purely forced convection flow.
2011-04-01
Manipulator for internal testing of a container. Manipulator zur Innenpruefung eines Behaelters
Energy Technology Data Exchange (ETDEWEB)
A manipulator for checking the inside of a vertical, flange-shaped collector of a horizontal steam generator consists of a rotating mast with bearings at the top and bottom ends with a support that can be moved along the length of the mast for the checking system mountings. The support is propelled by a drive spindle placed parallel to the mast with its drive head bearing in the support and locked into a toothed rack attached to the mast. The checking system mountings are fitted in or on the walls of the support and are very close to the box-shaped support. Their retractable arms are hinged.
1985-04-11
Loss of flow accident analysis of a water-cooled fusion reactor
International Nuclear Information System (INIS)
Within the APROS simulation environment we have built a thermo-hydraulic model of a conceptual fusion power plant which is water cooled and uses lithium-lead for tritium breeding. For the safety assessment of this design we have studied an accident sequence which starts from a loss or coolant flow then leads to first wall breach and pressurisation of the vacuum vessel. Simulations have revealed strong pressure transients which can be alleviated by design changes. One goal is to verify the adequacy of the containment design: it remains intact at least 14 h without any mitigating efforts. Estimates for radioactive releases are obtained. (author)
2003-08-25
Energy Technology Data Exchange (ETDEWEB)
The conceptual design, parametric analysis, cost and performance analysis, and commercial assessment of a 100-MWe line-focus solar central receiver power plant are reported. This volume contains the appendices: (a) methods of determination of molten salt heat-transfer coefficients and tube-wall temperatures, (b) inputs for STEAEC programs, (c) description of system analysis computer program, (d) receiver analysis program, and (e) heliostat production plan and design methodology. (WHK)
1980-04-01
Japanese R&D on new cast alloys and materials
Energy Technology Data Exchange (ETDEWEB)
On the basis of observations of the JTEC team, it appears that Japanese universities and research institutes are leading long-term R&D thrusts for development of new materials casting technologies. Significant efforts include amorphous metals, intermetallics, application of MHD in continuous casting of steel, and energy efficient furnace technology. Industrial R&D seems focused more on process improvements than on new product technologies, but significant efforts in new cast materials included cast metal matrix composites, materials substitutions for thinner wall products, and advanced ceramic products for foundry industry applications.
1996-05-01
JET contribution to ITER fuel cycle issues
Energy Technology Data Exchange (ETDEWEB)
The Joint European Torus (JET) fusion machine is the only device capable of operation with tritium (as fuel) and Be (as plasma facing component), what makes it best suited to study ITER relevant issues. A large variety of activities are performed within the JET Fusion Technology Task Force. In this paper, some topics such as erosion/deposition and material transport, flakes characterization and detritiation techniques are highlighted. Recent results obtained using a pumping cryo-panel and on plasma facing component characterisation are given. Finally, issues that will be addressed in the forthcoming JET work-programme are presented, such as a beryllium main wall for JET and in-situ laser detritiation. (authors)
2005-07-01
Interpolation theory and influence of boundary conditions on room air diffusion
Energy Technology Data Exchange (ETDEWEB)
This paper analyses the errors caused by interpolation from existing cases for assessing indoor air flow, air quality and thermal comfort in an office. A sensitivity study is then provided to determine the influence of several boundary conditions on indoor air diffusion. The research is conducted numerically by using a low-Reynolds-number k-{epsilon} model. It can be concluded that the interpolation errors caused by the variations of solar radiation, window size, heat source location due to lighting, and the surface temperatures of interior walls are small and can be quantitatively determined. But it is difficult to estimate the errors introduced by the variations of furniture location and size. (author).
1991-01-01
Hydrothermal coupling in a rough fracture
Heat exchange during laminar flow is studied at the fracture scale on the basis of the Stokes equation. We used a synthetic aperture model (a self-affine model) that has been shown to be a realistic geometrical description of the fracture morphology. We developed a numerical modelling using a finite difference scheme of the hydrodynamic flow and its coupling with an advection/conduction description of the fluid heat. As a first step, temperature within the surrounding rock is supposed to be constant. Influence of the fracture roughness on the heat flux through the wall, is estimated and a thermalization length is shown to emerge. Implications for the Soultz-sous-For\\^{e}ts geothermal project are discussed.
2006-01-01
Energy conservation by means of integrated systems; Beter resultaat door klimaatkwartet
Energy Technology Data Exchange (ETDEWEB)
Air conditioning is getting maximum attention these days when building new offices. For the new office building of the assurance company Zwitserleven in Amstelveen, Netherlands, a new air conditioning concept is applied, based on four existing air conditioning methods: cold storage and heat storage in the soil, heat pump, double-wall facades with integrated climate control, and radiant heating combined with a cooling system in the ceiling. The integration of these methods not only provides complete climate comfort for the employees but also substantial energy savings. 3 figs.,1 ills.
1995-11-01
Electromagnetic characterization of superconducting radio-frequency cavities for gw detection
International Nuclear Information System (INIS)
The electromagnetic properties of a prototype gravitational wave detector, based on two coupled superconducting microwave cavities, were tested. The radio-frequency (rf) detection system was carefully analysed. With the use of piezoelectric crystals small harmonic displacements of the cavity walls were induced and the parametric conversion of the electromagnetic field inside the cavities explored. Experimental results of bandwidth and sensitivity of the parametric converter versus stored energy and voltage applied to the piezoelectric crystal are reported. A rf control loop, developed to stabilize phase changes on signal paths, gave a 125 dBc rejection of the drive mode on a time scale of 1 h.
2004-03-07
Efficient Cartesian-grid-based modeling of rotationally symmetric bodies
DEFF Research Database (Denmark)
Axially symmetric waveguides, resonators, and scatterers of arbitrary cross section and anisotropy in the cross section can be modeled rigorously with use of 2-D Cartesian-grid based codes by means of mere redefinition of material permittivity and permeability profiles. The method is illustrated by the frequencydomain simulations of resonant modes in a circular-cylinder cavity with perfectly conducting walls, a shielded uniaxial anisotropic dielectric cylinder, and an open dielectric sphere for which, after proper implementation of the perfectly matched layer boundary conditions, the radiation quality factor is also determined.
2007-01-01
Dynamic response of pipelines buried in back-filled trenches
Energy Technology Data Exchange (ETDEWEB)
Dynamic response of pipelines buried in a back-filled rectangular trench in a semi-infinite medium has been investigated. The pipelines are modeled as long cylindrical shells of small thickness. By using the boundary integral representation and finite element method, we have studied the three-dimensional response to account for either pane P or SV wave incident at an arbitrary angle to the pipe-axis. In this paper numerical results are presented for the normal displacements, displacements along pipe-axis, and the hoop stresses in the pipe wall. It is shown that the response depends critically on the back-filled material as well as on the directions of propagation of the incident waves.
1991-08-01
Development of conductive nanotemplates on ZnSe
International Nuclear Information System (INIS)
We demonstrate the possibility to fabricate arrays of pores oriented perpendicular and parallel to the top surface of the ZnSe nanotemplate. The control of material conductivity allows one to produce porous ZnSe samples with the mean pore diameter and characteristic skeleton wall thickness from several hundreds of nanometers to about 15 nm. In addition, electrochemical treatment of ZnSe single crystals using photoresist masks allows one to prepare buried porous structures with pores directed parallel to the top template surface, which is especially important for photonic applications.
2011-07-07
DOE education and training grant. Final report
Energy Technology Data Exchange (ETDEWEB)
The work reported included workshop-style, hands-on training sessions to reach three hundred residents of the Detroit area. The training was for teaching low-cost weatherization applications; teaching/constructing/installing thermal shades; and teaching/constructing/installing vertical wall solar air panels. All activities under the grant are summarized, including number and type of workshops, number of participants trained, etc. The organizations which actively supported and contributed to the program are identified, and the program's efforts and accomplishments are evaluated. (LEW)
1982-01-01
Corrosion studies at the Wilsonville, Alabama, coal liquefaction facility during 1983
During 1983, Oak Ridge National Laboratory continued a study of materials performance at the Wilsonville, Alabama, Advanced Coal Liquefaction Research and Development Facility. Materials performance was evaluated by exposure and analysis of corrosion coupons and U-bend specimens, chemical analysis of related process streams, and ultrasonic determination of the thickness of walls of various components. The results of these studies are useful to current plant operators and to designers of future large-scale plants. 18 references, 4 figures, 12 tables.
1984-10-01
Combined effect of magnetic field and thermal dispersion on a non-darcy mixed convection
British Library Electronic Table of Contents (United Kingdom)
This paper is devoted to investigate the influences of thermal dispersion and magnetic field on a hot semi-infinite vertical porous plate embedded in a saturated Darcy-Forchheimer-Brinkman porous medium. The coefficient of thermal diffusivity has been assumed to be the sum of the molecular diffusivity and the dynamic diffusivity due to mechanical dispersion. The effects of transverse magnetic field parameter (Hartmann number Ha), Reynolds number Re (different velocities), Prandtl number Pr (different types of fluids) and dispersion parameter on the wall shear stress and the heat transfer rate are discussed.
2011-01-01
Analysis of laminar flow heat transfer in uniform temperature circular tubes with tape inserts
Constant property, laminar flow heat transfer in a semicircular tube with uniform wall temperature has been analyzed to define the lower bound of heat transfer augmentation in circular tubes with twisted-tape inserts. Two thermal boundary conditions, which correspond to the two extremes of the fin effect of twisted tapes encountered in practical applications, are considered. Numerical solutions, employing finite-difference formulations for the governing momentum and energy equations were carried out for the thermal entrance region and for fully developed flow.
1986-05-01
Energy Technology Data Exchange (ETDEWEB)
We present a case of cerebral aspergillosis in an immunocompetent patient. The MRI signal characteristics were compared with the histologic findings. Irregular low-signal zones were demonstrated between the wall of the abscess and the central necrosis on T2-weighted images; the pathology specimen revealed concentrated iron in these transitional zones but no hemosiderin. Iron is an essential element for the growth of fungal hyphae. The low-signal zones may represent the areas where there was active proliferation of aspergillus, and the unique location of the low signal may be a helpful imaging characteristic for the diagnosis of an aspergillus abscess. (orig.)
2001-07-01
AAR in concrete of Asejire spillway (OYO state - Nigeria)
Energy Technology Data Exchange (ETDEWEB)
The Asejire dam at Ibadan, Nigeria was constructed in the late sixties for the purpose of providing water for the city of Ibadan (presently about 4,5 million inhabitants). It is located on the Oshun river approximately fifteen miles from the city. In 1982 cracks were observed on the wing walls and although these continued to develop, no attempt was made at that time to investigate their causes and no repair was carried out. In 1989 the SGI ENGINEERING Group of Geneva, Switzerland was appointed as the consultant for the complete refurbishment of the Asejire water scheme. The consortium Degremont-Poat-Clemessy was awarded the contract for the project. The African Development Bank and the Nigerian Government have provided the loan to finance the project.
1995-12-31
[sup 123]I-MIBG myocardial scintigraphy in diabetic patients. Association with autonomic neuropathy
Energy Technology Data Exchange (ETDEWEB)
[sup 123]I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy was performed in 20 diabetic patients (NIDDM) and 8 control subjects to investigate the association between clinical autonomic nerve dysfunction and myocardial accumulation of MIBG. We used coefficient variance of R-R interval (CV[sub R-R]) as a index of the autonomic neuropathy and categorized diabetes into two groups (CV[sub R-R][>=]2.0: non-autonomic neuropathy. CV[sub R-R]<2.0: autonomic neuropathy). In planar imaging studies, heart to mediastinum MIBG uptake ratio (H/M) was calculated on both early and delayed images. The washout ratio of [sup 123]I-MIBG in the heart (%WR) was also obtained using myocardial tracer activity on the both images. Mean value of these indices in diabetic group did not reveal any significant difference with the value in the control group. On the SPECT images, low uptake was observed in the posterior-inferior wall with normal uptake of [sup 201]Tl in diabetic ...
1994-09-01
Two Dimensional CFD Analyses on the Heat Transfer for a Supercritical Pressure CO_2
International Nuclear Information System (INIS)
The Supercritical Water Cooled Reactor(SCWR) operates in a pressure around 25MPa and temperature of 293#approx#510 .deg. C. In order to study the heat transfer behaviors and good comparisons between the various fluids, a heat transfer test loop(SPHINX) using CO_2 has been constructed in KAERI as a part of international research program, I-NERI. At a supercritical pressure, the heat transfer coefficient is much larger than that estimated from the Dittus-Boelter correlation for a relatively large flow rate with moderate wall heat flux conditions. This phenomenon was explained by the rapid variations of the physical properties near the wall with the temperature. On the contrary, the heat transfer becomes worse when the bulk fluid enthalpy is below the pseudo-critical enthalpy under a low flow rate with large heat flux conditions. This phenomenon is called 'deteriorated heat transfer', and which is explained as the modification of the shear stress ...
2005-10-27
International Nuclear Information System (INIS)
Purpose: Treatment results and the pattern of relapse were evaluated in the multimodal treatment of Ewing's sarcomas of the chest wall. Methods and Materials: In a retrospective analysis, 114 patients with non-metastatic Ewing's sarcoma of the chest wall were evaluated. They were treated in the CESS 81, CESS 86, or EICESS 92 studies between January 1981 and December 1993. The treatment consisted of polychemotherapy (VACA, VAIA, or EVAIA) and local therapy, either surgery alone (14 patients), radiotherapy alone (28 patients) or a combination of both (71 patients). The median follow-up was 46.6 months (range 5-170). A relapse analysis for all patients with local or combined relapses was performed. Results: Overall survival was 60% after 5 years, event-free survival was 50%. Thirty-seven patients had a systemic relapse (32.4%), 11 patients had a local relapse alone (9.6%), and 3 patients had a combined local and systemic relapse (2.6%). The risk ...
1998-12-01
Preoperative staging of rectal carcinoma with combined sonography and pelvic computed tomography
International Nuclear Information System (INIS)
The accurate staging of rectal carcinoma is very important for treatment planning. The histological data obtained from surgical specimens of 22 patients with rectal carcinoma were compared with pre-and postoperative endorectal US findings and with preoperative CT results. According to an adapted version of Astler and Coller classification, the different degrees of tumor spread into the rectal wall were represented as follows: stage A: 1 patient; stage B1: 5 patients; stage B2: 6 patients; stage C1: 1 patient; stage C2: 8 patients and stage D: 1 patient. Preoperative staging, based on the overall results of CT and US, was in agreement with histology in 19 of 22 cases. Individual analysis of US and CT results, in comparison with histological data, showed US staging accuracy to be 77.3% (17/22 patients). US accuracy in demonstrating tumor spread into the rectal wall (stages A, B1, C1) was 100% (7/7 patients); US was 70% accurate in lymph node ...
1991-01-01
Numerical study of the impingement of a supersonic, axisymmetric jet on a flat plate
International Nuclear Information System (INIS)
A numerical method for studying the flow field of an under-expanded axis-symmetric jet created by a converging-diverging nozzle and impinging on a flat plate is presented. The calculation domain of interest is a region that contains all the features of the jet that leaves the nozzle and impinges onto the plate. Axial symmetry of the domain allows a reduced 2-dimensional model to be used. FLUENT software is utilized to solve the continuity, momentum and energy equations using a coupled implicit scheme. The ideal-gas law is used to determine the gas density along with a k-#epsilon# turbulence model with a special modification to account for compressibility effects. In addition, the temperature dependency of viscosity has been taken into consideration. A number of different modeling techniques are investigated including different approximations to account for the flow inside the nozzle. Performance of non-equilibrium wall functions for near-wall ...
Energy Technology Data Exchange (ETDEWEB)
This work was carried out to understand the behavior of the solid and gas phases in a CFB riser. Only the riser is modeled as a straight pipe. A model with linear algebraic approximation to solids viscosity of the form, {musubs} = 5.34{epsisubs}, ({espisubs} is the solids volume fraction) with an appropriate boundary condition at the wall obtained by approximate momentum balance solution at the wall to acount for the solids recirculation is tested against experimental results. The work done was to predict the flow patterns in the CFB risers from available experimental data, including data from a 7.5-cm-ID CFB riser at the Illinois Institute of Technology and data from a 20.0-cm-ID CFB riser at the Particulate Solid Research, Inc., facility. This research aims at modeling the removal of hydrogen sulfide from hot coal gas using zinc oxide as the sorbent in a circulating fluidized bed and in the process indentifying the parameters that affect the ...
2005-07-01
Mechanisms of cobalt uptake in plants: {sup 60}Co uptake and distribution in Chara
Energy Technology Data Exchange (ETDEWEB)
The mechanism of cobalt uptake was investigated using cells of the giant alga Chara corallina in which it is possible to resolve separately uptake by the cell wall and actual influx across the cell membrane. The absorption of {sup 60}Co by Chara cells appeared to saturate within 2 h. but this was mainly due to rapid uptake into the cell wall which accounted for 87-92% of the total activity. Even after prolonged desorption most of the cell-associated {sup 60}Co was found on the cell wall. The intracellular distribution of absorbed {sup 60}Co was investigated by fractionating the cell into cytoplasm and vacuole. It was shown that {sup 60}Co influx to the vacuole occurs simultaneously with influx to the cytoplasm. The transported species appears to be Co{sup 2+} rather than the less charged Co(OH){sup +} or Co(O){sub 2}. {sup 60}Co influx is pH dependent (optimum pH 7-9), and is sensitive to some other divalent metals. Influx ...
1998-12-31
Mechanisms of cobalt uptake in plants: "6"0Co uptake and distribution in Chara
International Nuclear Information System (INIS)
The mechanism of cobalt uptake was investigated using cells of the giant alga Chara corallina in which it is possible to resolve separately uptake by the cell wall and actual influx across the cell membrane. The absorption of "6"0Co by Chara cells appeared to saturate within 2 h. but this was mainly due to rapid uptake into the cell wall which accounted for 87-92% of the total activity. Even after prolonged desorption most of the cell-associated "6"0Co was found on the cell wall. The intracellular distribution of absorbed "6"0Co was investigated by fractionating the cell into cytoplasm and vacuole. It was shown that "6"0Co influx to the vacuole occurs simultaneously with influx to the cytoplasm. The transported species appears to be Co"2"+ rather than the less charged Co(OH)"+ or Co(O)_2. "6"0Co influx is pH dependent (optimum pH 7-9), and is sensitive to some other divalent metals. Influx from solutions containing 1 #mu#M ...
1998-01-01
Effective stress of a 4.2 K beam tube in a quenching collider 50 mm dipole magnet for the SSC
Energy Technology Data Exchange (ETDEWEB)
Two mechanical design requirements are defined for the SSC Collider beam tube. First, the vacuum requirement (luminosity lifetime = 150 hrs). It requires the design of a pressure boundary within the cold mass vessel to provide a vacuum tunnel for the proton beam and to minimize the synchrotron radiation gas desorbtion with a suitable material. The Collider beam tube design is under an intensive activity to search for a material that will meet the luminosity requirement without a distributed pump or liner. Second is the tube wall`s resistivity requirement ({sigma}*t = 2E5 {Omega}{sup {minus}1}). For a 4.2 K beam tube the Cu thickness is 100 {mu}m (RRR=30,6.7 T, {sigma}=2E9{Omega}{sup {minus}1}m{sup {minus}1}). The copper yield strength is relatively low in comparison to steel and, therefore, the design of the steel layer is governed by the copper layer yield stress limit. A beam tube subjected to eddy current load in a quenching dipole requires an optimum diameter ...
1993-05-01
Development of an inactive heat removal system for high temperature reactors
International Nuclear Information System (INIS)
Growing public and political interests towards incorporating passive safety features in nuclear installations, let Siempelkamp in late 1987 propose a solution consisting of a prestressed cast-iron pressure vessel and a passive heat removal system, integrated in the reactor cell surrounding the vessel. This solution combines the inherent safety of a prestressed metallic pressure vessel with the advantages of a passive heat removal system and thus constitutes a major step towards the goal of further reducing potential residual risks. The design had to meet the boundary conditions for reactor core and reactor building of the modular 200 MWth pebble bed reactor of Siemens/-KWU. The engineering design showed that many input parameters needed for the finite-element-analysis of the overall structure required a verification by measurements in a well scaled test setup. This was especially required for the heat transfer from the liner of the prestressed cast-iron pressure vessel to the natural ...
1994-08-01
Energy Technology Data Exchange (ETDEWEB)
Experiments for lifetime prediction of the first wall are being carried out within the framework of the European fusion reactor programme. Defects such as notches and cavities may develop in the first wall and may initiate under cyclic thermal stress cracking processes which may reduce the service life of the material. For examination of crack growth, specimens with defined initial notches were prepared and subjected to cyclic thermal loads. The paper shows that the eddy current method is suitable for detecting and revealing the crack growth processes even under conditions of complex geometry, as e.g. cracks in inner bores. The experiments indicated particularly susceptible, critical spots in the first wall and yielded crack growth rates of use for lifetime calculations. (orig./CB) [Deutsch] Im Rahmen des europaeischen Fusionsreaktorprogramms werden Untersuchungen zur Lebensdauervorhersage der Ersten-Wand durchgefuehrt. Die ...
1997-12-31
Phytochrome-induced Increase of Fluorescein Translocation in Mung Bean Hypocotyls
UK PubMed Central (United Kingdom)
Moderate doses of red (660 nanometer) irradiation cause a rapid increase in the translocation of fluorescein in dark-grown mung bean hypocotyl (Vigna radiata L.) segments. The increase...Full Text Available
1978-07-01
Improving yield of industrial biomass propagation by increasing the Trx2p dosage
UK PubMed Central (United Kingdom)
The beneficial effect of improving yeast redox response by increasing thioredoxin levels has been shown. Decreased lipid and protein oxidation is reflected in an increased biomass yield. In addition,...Full Text Available
2010-09-01
The Challenges of Colorectal Cancer Survivorship
UK PubMed Central (United Kingdom)
With advances in treatment, colorectal cancer is being transformed from a deadly disease to an illness that is increasingly curable. With this transformation has come increased interest in the...Full Text Available
2009-09-01
UK PubMed Central (United Kingdom)
Increasing evidence suggests that sex differences exist in the etiology, presentation, treatment, and outcome from stroke. The reasons for these sex disparities are becoming increasingly explored, but...Full Text Available
2008-11-01
Rifampin Combination Therapy for Nonmycobacterial Infections
UK PubMed Central (United Kingdom)
Summary: The increasing emergence of antimicrobial-resistant organisms, especially methicillin-resistant Staphylococcus aureus (MRSA), has resulted in the increased...Full Text Available
2010-01-01
Titanium Alloys for Medical Instrumentation
International Science & Technology Center (ISTC)
The New Titanium Alloys With Increased Mechanical Properties and Corrosion Resistance for Medical Instruments and their Coatings
Thermodynamics of superconductors with a disorder induced increased Coulomb repulsion
Energy Technology Data Exchange (ETDEWEB)
It is shown that thermodynamic properties can be used to determine whether, the degradation in Tsub(c) with increasing disorder observed in some A-15 compounds, is due to a reduction in electronic density of states and/or electron-phonon interaction or is due instead to an increase in Coulomb repulsion ..mu..* coming from increased localization as suggested by Anderson et al.
1985-03-01
Realistic and Affordable Cyberware Opponents for the ...
... Therefore, as the information management capabilities of military forces increase, there is a corresponding need for improved security for the ...
2003-06-01
Radial Halbach Magnetic Bearings
Radial Halbach magnetic bearings have been investigated as part of an effort to develop increasingly
2009-01-01
colonies known as biofilms are known to harbour food-borne pathogens . These biofilms also have an increased resistance
Effect of WC particle size on grain growth inhibition in the WC-xVC-Co system
Energy Technology Data Exchange (ETDEWEB)
The effect of WC particle size with the addition of VC as a grain growth inhibitor was investigated during the liquid phase sintering of WC-Co system. With increasing WC particle size at the same VC content, the effect of grain growth inhibition was increased. Also, with increasing the VC content, the grain shape of WC was changed from the faceted shape to the distorted shape, and the step density of the WC grain was increased. (orig.)
2003-07-01
International Nuclear Information System (INIS)
Purpose: To assess the role of CT in the evaluation of traumatic and spontaneous oesophageal perforation. Materials and methods: From March 2001 to May 2003, we studied 12 patients (7 males and 5 females; age range: 25-66 years, mean age: 43.5 years) with suspected oesophageal perforation due to motor-vehicle accidents (4 cases), stab wound (one case), post-intubation (2 cases), foreign body ingestion (2 cases) and spontaneous (3 cases). Five patients underwent standard chest and cervical radiography; two patients with suspected foreign body ingestion also underwent a gastrografin swallow study; all of the 12 patients underwent CT of the neck, chest and abdomen before and after intravenous, and in four cases oral, administration of contrast material. Results: In 5 patients with cervical, thoracic and abdominal trauma, the CT examination showed the presence of pleuroparenchymal injury (pneumothorax, pleural effusion and subcutaneous emphysema) as well as findings suggestive of ...
2005-03-01
Application of the porous media model for the LWR process components
Energy Technology Data Exchange (ETDEWEB)
Full text of publication follows: A porous media solution PORFLO has been developed for the 3-dimensional two-phase flow by describing the process facility in Cartesian or cylindrical coordinates. The local porosity fraction is applied for distinguishing the fluid filled volumes from the solid structures. The solid structure contribute the two-phase flow through the wall friction, flow area and heat transfer. Optionally the solid structure may contain primary liquid of steam generators, steam in the higher temperature and pressure to be condensed or electrical heating power. By using these optional boundary conditions three different process facilities have been analysed. The thermohydraulic solution based on 5-equation approach, where the conservation equations are solved for the liquid and gas (vapour) mass, mixture momentum (giving the velocity only for the mixture), liquid and gas energy, is described shortly. In addition to that the principles modelling ...
2005-07-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
