WorldWideScience
4

Pneumomediastinum as a Complication of Extraperitoneal Laparoscopic Inguinal Hernia Repair  

UK PubMed Central (United Kingdom)

A 52-year-old man with left indirect groin hernia was admitted for elective inguinal repair using the totally extraperitoneal (TEP) approach. After an uneventful intubation, TEP repair of the hernia...Full Text Available

1999-07-01

5

Pneumothorax during laparoscopic repair of giant paraesophageal hernia  

UK PubMed Central (United Kingdom)

Giant paraesophageal hernia is an uncommon morbid disorder which may present a risk of catastrophic complications and should be repaired electively as soon as possible. Laparoscopic fundoplication is...Full Text Available

2011-07-01

6

Adult Morgagni Hernia: The Need for Clinical Awareness, Early Diagnosis and Prompt Surgical Intervention  

UK PubMed Central (United Kingdom)

We report an unusual case of strangulated diaphragmatic (Morgagni) hernia resulting in ischaemia of the small and large bowel, which was initially diagnosed as a pneumonia. This case highlights the...Full Text Available

2008-11-01

7

A late presenting congenital diaphragmatic hernia misdiagnosed as spontaneous pneumothorax  

UK PubMed Central (United Kingdom)

Congenital diaphragmatic hernia (CDH) is described as (1) failure of diaphragmatic closure at development, (2) presence of herniated abdominal contents into chest and (3) pulmonary hypoplasia. Usually,...Full Text Available

2010-09-01

8

A comparative study of standard versus laparoendoscopic single-site surgery (LESS) totally extraperitoneal (TEP) inguinal hernia repair  

British Library Electronic Table of Contents (United Kingdom)

Background Laparoscopic inguinal hernia repair has been around since the 1990s. A novel surgical approach known as laparoendoscopic single-site surgery (LESS) has been developed to reduce the port-related morbidities and improve the cosmetic outcomes of laparoscopic surgery, including totally extraperitoneal (TEP) inguinal hernia repair. The aim of the present study was to evaluate the safety and feasibility of the LESS TEP technique for inguinal hernia repair and compare the outcomes with the standard TEP approach. Methods Between January and May 2009, 54 consecutive healthy patients (48 men and 6 women) underwent LESS TEP inguinal hernia repair at our institute. All procedures were performed using our homemade single port for simultaneous passage of the laparoscope and instruments. The p...

2011-01-01

9

Inguino-scrotal hernia detection in the early phase of a bone scan  

International Nuclear Information System (INIS)

A large inguino-scrotal hernia was detected in the early phase of a radionuclide bone scan performed for evaluation of a femoral neck fracture not visualized on plain x-rays. The patient was administered 1 GBq of Scrotal scintigraphy using "9"9"mTc-MDP and a regional three-phase bone scan of the pelvis, hips and proximal femora was obtained on the gamma camera. Copyright (1999) Blackwell Science Pty Ltd

1999-11-01

10

Three-dimensional, three-component wall-PIV  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a new time-resolved three-dimensional, three-component (3D-3C) measurement technique called wall-PIV. It was developed to assess near wall flow fields and shear rates near non-planar surfaces. The method is based on light absorption according to Beer-Lambert's law. The fluid containing a molecular dye and seeded with buoyant particles is illuminated by a monochromatic, diffuse light. Due to the dye, the depth of view is limited to the near wall layer. The three-dimensional particle positions can be reconstructed by the intensities of the particle's projection on an image sensor. The flow estimation is performed by a new algorithm, based on learned particle trajectories. Possible sources of measurement errors related to the wall-PIV technique are analyzed. The accuracy analysis was based on single particle experiments and a three-dimensional ...

2010-06-15

11

Simultaneous assessment of left ventricular function from gated myocardial perfusion SPECT. Utility of QGS (Quantitative Gated SPECT) program  

International Nuclear Information System (INIS)

Quantitative gated SPECT (QGS) was evaluated in 7 normal volunteers and 31 patients with cardiac diseases. Adequate cut off value of a prefilter was 0.45. In phantom, the left ventricular volume value was 93.9% of determined value by 180-degree projection in L type and 98.8% by 360-degree projection in opposed type. In normal volunteers, LVEF measured by QGS program related to value by first pass method. As for functional map, regional EF and wall motion decreased at the septum side, and wall thickening at base side of heart. Good correlation was recognized (p<0.0001) between blood flow image and functional map (regional EF and wall thickening). In 20 cases of acute myocardial infarction, lesion was detected conspicuously in regional EF and wall motion. The accuracy of coronary arterial stenosis improved in functional map (regional EF 92%, wall motion 92% and ...

1998-08-01

12

Myocardial imaging in patients with Kawasaki disease. Exercise stress imaging and serial studies  

Energy Technology Data Exchange (ETDEWEB)

Thallium-201 myocardial imaging was performed in 80 children with coronary arterial lesions due to Kawasaki disease in order to assess the value of serial and exercise myocardial imagings. In eight of these children, abnormalities of the image were noted. Twenty children had serial thallium studies with an interval of three to 18 months, and five of these showed changes in the image including appearance of a new perfusion defect in one patient and improvement of perfusion defects in four. These changes of the myocardial image were correlated well with coronary angiographic findings obtained within a few days of the isotope studies. It was noted that the changes of the myocardial image were more frequently observed at relatively recent period recovered from Kawasaki disease. Exercise myocardial imaging using a bicycle ergometer was performed ...

1982-06-01

13

Computed tomography of the mediastinal lesion  

Energy Technology Data Exchange (ETDEWEB)

Authors retrospectively analyzed the CT findings of mediastinal lesions in surgically or clinically confirmed 37 cases at Kosin Medical College during recent 4 years from September 1979 to August 1983. 1. Among 37 caes, malignant lymphoma were 7 cases, thymoma and vascular lesion or anomaly were 5 cases respectively, benign teratoma and tuberculous mediastinal lymphadenitis and neurogenic tumor were 4 cases respectively, pericardial cyst were 2 cases, bronchogenic cyst, non-specific cyst, pancreatic pseudocyst, mesothelioma, Bochdalek hernia was 1 case respectively. 2. The sex ratio between male and female was about 1 : 1 and the majority of the patients with malignant lymphoma and teratoma was under 20 years old. 3. CT findings of the each mediastinal lesion. 1) Primary mediastinal malignant lymphoma. (1) A large, matted, continuous and midline-crossing mass was observed in the superior and the anterior mediastinums in all cases. (2) In 3 cases, irregular lower ...

1984-09-15

14

Mesh repair of a coccygeal hernia via an abdominal approach.  

UK PubMed Central (United Kingdom)

We report on the presentation and management of a patient with herniation of the rectum following a coccygectomy. We used an abdominal approach and careful pelvic dissection to define the defect in...Full Text Available

2000-03-01

15

Intrauterine tracheal obstruction, a new treatment for congenital diaphragmatic hernia, decreases amniotic fluid sodium and chloride concentrations in the fetal lamb.  

UK PubMed Central (United Kingdom)

OBJECTIVE: To evaluate the effect of fetal tracheal occlusion on sodium and chloride concentrations in amniotic and tracheal fluid. SUMMARY BACKGROUND DATA: Intrauterine tracheal occlusion has been...Full Text Available

1997-12-01

16

Cystic Dysplasia of the Rete Testis Accompanying an Inguinal Hernia: A 63-Year-Old Man  

UK PubMed Central (United Kingdom)

Cystic dysplasia of the rete testis (CDT) is a very rare congenital benign testicular tumor that is often associated with ipsilateral genitourinary anomalies. It is usually found in the pediatric population...Full Text Available

2011-07-01

17

An intracranial aspergilloma with low signal on T2-weighted images corresponding to iron accumulation  

Energy Technology Data Exchange (ETDEWEB)

We present a case of cerebral aspergillosis in an immunocompetent patient. The MRI signal characteristics were compared with the histologic findings. Irregular low-signal zones were demonstrated between the wall of the abscess and the central necrosis on T2-weighted images; the pathology specimen revealed concentrated iron in these transitional zones but no hemosiderin. Iron is an essential element for the growth of fungal hyphae. The low-signal zones may represent the areas where there was active proliferation of aspergillus, and the unique location of the low signal may be a helpful imaging characteristic for the diagnosis of an aspergillus abscess. (orig.)

2001-07-01

18

Role of early phase helical CT images in the evaluation of wall invasion of colorectal cancer. Pathological correlation  

Energy Technology Data Exchange (ETDEWEB)

The usefulness of helical CT early phase images optimized by the SmartPrep method for evaluation of wall invasion by colorectal cancer was investigated. Between August 1997 and September 1998, CT was performed to evaluate the primary tumor and local extension in 10 consecutive patients with colorectal cancer confirmed by barium enema- and/or colonoscopy. Early-phase images were acquired by using SmartPrep application software. This method allows the optimal scan delay time to be obtained by continuous monitoring of increases in CT values after injection of contrast medium. Sections of the surgical specimens, close to the same plane as the CT images, and of the same slice thickness, were analyzed histopathologically. All 10 cancers, regardless of size, showed strong enhancement on the early-phase images (81.4-112 HU, mean: 95.1 HU). The strongly enhanced image ...

2000-02-01

19

Assessment of left ventricular wall motion by optional multiple long-axial gated blood pool SPECT  

International Nuclear Information System (INIS)

Optional multiple long-axial gated blood pool SPECT images were prepared for the purpose of stereoscopic and quantitative imaging of left ventricular wall motion (LVWM). Sixteen patients with ischemic heart disease and 8 healthy subjects were imaged in 32 views in the 360 degrees position after iv injection of 740 MBq of Tc-99m-labeled human serum albumin D. The R-R interval was divided into 16. After preparing conventional oblique images, long-axial images were prepared. Shortening rate of left ventricular wall was calculated in 5 segments of the apex and base of the left ventricle. An average shortening rate in each segment was graded with a score from a minimum of 0 to a maximum of 40% or more. In the normal group, shortening rate in each segment, except for the base of the septal region, exceeded 40%. In the group of ischemic heart ...

1991-01-01

20

Determination of left ventricular ejection fraction and wall thickness in magnetic resonance imaging at 1.0 Tesla in comparison to echocardiography and biplanar ventriculography  

International Nuclear Information System (INIS)

We compared the values of the myocardial thickness and the left ventricle diameters measured with MRI and echocardiography. The ejection fraction was compared in MRI and ventriculography. 34 patients with different heart dysfunctions were examined with MRI (FISP 2D sequence). 26 of them were also studied by echocardiography and 20 by biplane cine-ventriculography. The enddiastolic thicknesses of the left ventricular postero-lateral wall and of the septum interventriculare were measured on short axis images. An ellipsoidal modell was used for volume calculation and ejection fraction. Correlation of MRI values of thickness and ejection fraction with echocardiographi and angiographi showed r>0,8. As known for 1.56 T Imagers, the myocardial thickness in MRI was underestimated compared to echocardiography (1.4 mm#+-#1.7). The ejection fraction was underevaluated compared to ventriculography (4.5%#+-#10.1). MRI (1.0 T) ...

21

Enhanced CT in the diagnosis of acute appendicitis to evaluate the severity of disease. Comparison of CT findings and histological diagnosis  

Energy Technology Data Exchange (ETDEWEB)

To assess the potential of CT in evaluating the histological severity of acute appendicitis in comparison with surgical and pathological findings. The CT images of 75 patients with surgically proven appendicitis, including 10 cases of catarrhal, 34 of phlegmonous, and 31 of gangrenous appendicitis, were retrospectively analyzed for the following five CT findings: hazy periappendiceal densities, enlarged appendix, increased enhancement of the appendiceal wall, increased enhancement of the periappendiceal intestinal wall, and deficiency of the appendiceal wall. By comparing all the CT findings and the pathological severity of appendicitis (catarrhal, phlegmonous, and gangrenous), the prevalence of the five CT findings was calculated for each pathological category. Abnormal CT findings were noted in only one case of catarrhal appendicitis. Increased enhancement of the appendiceal wall ...

2001-08-01

22

Direct sub-nanometer scale electron microscopy analysis of anion incorporation to self-ordered anodic alumina layers  

International Nuclear Information System (INIS)

Research highlights: #-># Morphological and chemical characterization at atomic scale of porous alumina layers anodised in ordered regimes. #-># Characterization based on the use of FEG-SEM, STEM-HAADF, STEM-EELS and STEM-X-EDS. #-># Nanoscale distribution of P-, C- and S-bearing species in the pore wall. - Abstract: Ordered porous alumina layers prepared by two-step anodising in phosphoric, oxalic and sulphuric acids have been characterized at sub-nanometer scale using electron microscopy techniques. FEG-SEM and STEM-HAADF images allowed estimating the pore size, cell wall and pore wall thicknesses of the layers. Nanoanalytical characterization has been performed by STEM-EELS and STEM-X-EDS. Detailed features of the spatial distribution of anions in the pore wall of the films have been obtained. Maximum concentration of P-species occurs, approximately, at the middle of the ...

2010-11-01

23

Spray, combustion, and heat transfer studies in a Ricardo hydra direct-injection diesel engine  

Energy Technology Data Exchange (ETDEWEB)

The spray and combustion development in a single-cylinder, direct-injection diesel engine equipped with optical access was examined using a number of complementary techniques. A laser imaging system, based around a pulsed copper-vapour laser synchronised to an intensified CCD camera, was used to obtain images of the four fuel sprays prior to combustion, and to determine the tip penetration of each spray as a function of crankangle. The surface heat flux to the wall of the piston bowl was measured by placing a fast-response thermocouple at the impingement point of one of the sprays, and a two-colour imaging system was used to obtain digital images of the flame temperature and equivalent soot distribution in the cylinder. (author)

1996-12-31

24

Removal of scattered thermal neutrons using antiscatter grid  

International Nuclear Information System (INIS)

One of the significant factors of neutron radiographic image degradation is scattering blur from the object. A practical method is described to enhance image quality by eliminating the overlapping of scattered thermal neutrons component from the objects in ETRR-2 neutron radiography facility, using aluminum Gd-coated antiscatter grid. The MCNP code was used to determine the optimum grid dimensions that will reduce the scattered thermal neutrons from the object. An experiment was performed to determine the optimum grid height and irradiation time that gives the best image with acceptable geometric unsharpness. Using the MCNP code it was found that 97% of the scattered neutrons were removed by the grid. The wall dimensions and Gd coating are so small that the facility resolution cannot detect the image pattern superposition on the film.

2006-12-01

25

MRI findings of the brain in high-voltage electrical burn patient: case report  

Energy Technology Data Exchange (ETDEWEB)

We report the delayed sequelae arising in a case of electrical injury, reviewing the literature on the subject and focusing on the MRI findings of the brain. A 23-year-old male suffered burns to the left parietal scalp, both feet, and the anterior chest wall. Neurological symptoms and MRI abnormalities appeared 14 days after the insult and continued for about three months. T1-weight MR images demonstrated homogeneous hypointensity, while T2-weighted images depicted hyperintense finger-like projections. Contrast-enhanced T1-weighted images demonstrated strong band-like enhancement, indicating meningeal hyperemia. Follow-up MR imaging showed that the lesion had disappeared, indicating that the cerebral edema and meaningeal hyperemia were reversible.

2003-05-01

26

Comparison of fluid-dynamic modeling of flow with velocity-encoded MR imaging  

International Nuclear Information System (INIS)

This paper develops a fluid dynamic model using finite difference methods characterizing flow in phantoms simulating in vivo conditions and to compare those results with velocity encoded MR images. The phantom consisted of 1-inch (2.5-cm) tubing with semicircular insert and fluid with viscosity, T1, and T2 comparable to blood. Numeric solutions to Navier-Stokes equations for this system were obtained using finite difference methods, with velocity input function of zero at walls and parabolic at both ends. In resulting color raster (CR) images, color temperature represented velocity value. In velocity-encoded MR images acquired under the same flow conditions, phase is proportional to average velocity during application of flow-encoding gradients. Because these gradients are applied along one direction per acquisition, magnitude and direction of velocity are obtained.

1990-11-25

27

[sup 123]I-MIBG myocardial scintigraphy in diabetic patients. Association with autonomic neuropathy  

Energy Technology Data Exchange (ETDEWEB)

[sup 123]I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy was performed in 20 diabetic patients (NIDDM) and 8 control subjects to investigate the association between clinical autonomic nerve dysfunction and myocardial accumulation of MIBG. We used coefficient variance of R-R interval (CV[sub R-R]) as a index of the autonomic neuropathy and categorized diabetes into two groups (CV[sub R-R][>=]2.0: non-autonomic neuropathy. CV[sub R-R]<2.0: autonomic neuropathy). In planar imaging studies, heart to mediastinum MIBG uptake ratio (H/M) was calculated on both early and delayed images. The washout ratio of [sup 123]I-MIBG in the heart (%WR) was also obtained using myocardial tracer activity on the both images. Mean value of these indices in diabetic group did not reveal any significant difference with the value in the control group. On the SPECT images, low uptake was observed in the ...

1994-09-01

28

Investigation of Tumor-Peritoneal Interactions in the Pathogenesis of Peritoneal Metastases using a Novel Ex Vivo Peritoneal Model1  

British Library Electronic Table of Contents (United Kingdom)

BackgroundPeritoneal metastasis occurs in up to 30% of patients with gastric cancer. The aim of this experimental study is to develop and validate a novel ex vivo model of the human peritoneum to better identify factors involved in the development of peritoneal metastasis in order to improve its management and prognosis. MethodsPeritoneal discs harvested from hernia sacs obtained at inguinal hernia surgery were suspended in media using Teflon rings. Viability of the tissue was investigated using MTS assay, light and scanning electron microscopy (LM and SEM) over 72 h. To assess validity of the model, phenotypic changes in tumor cells were investigated. Changes in matrix metalloproteinases (MMP)-2 and -9 activities in HGC and AGS gastric adenocarcinoma cells after co-culture were investigat...

2010-01-01

29

Bariatric surgery complications. Internal hernia: A potentially fatal condition. A case report and literature review  

International Nuclear Information System (INIS)

In recent years, Obesity (defined as Body Mass Index > 30 kg/m2) has increased its prevalence reaching epidemic levels in countries such as The United States where it has became a national health issue. In Colombia the Obesity prevalence is figured around 14%. Treatment options for Obesity include life style modifications, pharmacologist management and surgical approach (Bariatric Surgery). This article describes a patient with previous bariatric surgery, who presents abdominal pain and melena owed to isquemic process of the alimentary limb caused by an internal hernia which is a potentially lethal condition if it is not highly suspected allowing its early diagnosis and treatment

30

PIV measurements of flow structures in a spray dryer  

DEFF Research Database (Denmark)

Stereoscopic Particle Image Velocimetry (PIV) measurements are made in horizontal planes in a simplified scale model of a spray dryer using water as fluid. The sample rate was sufficient to resolve phenomena at lower frequencies. Data reveal asymmetric velocity fields in both mean fields and dynamics. Data were analysed using Proper Orthogonal Decomposition (POD). An important periodic event is an elongation of the jet core cross section that results in a downstream displacement of the jet towards the chamber wall.

2011-01-01

31

Focal lesions in external auditory canal: computed tomography images  

International Nuclear Information System (INIS)

To analyze and review the most common focal lesions of the external auditory canal (EAC), describing the computed tomography (CT) findings. The CT images of EAC were reviewed in a series of 167 patients. Abnormal findings were recorded in 13 cases. The CT images were correlated with otoscopic and/or intraoperative findings. There were four cases of osteoma (one located outside the EAC); all of which were treated surgically, as was the one case of exostosis. Six patients presented debris in EAC, coinciding with clinical evidence of external otitis. There were two cholesteatomas derived from EAC, one of them secondary to survery to treat osteoma. On patient was diagnosed as having a basal cell carcinoma of the ear, extending to EAC, but refused to undergo surgery. Five patients presented small triangular laminae of dense bone arising from the upper wall of the EAC which were defined as abnormal variants of the fusion of the ...

32

MR imaging and MR cholangiopancreatography in the preoperative evaluation of hilar cholangiocarcinoma: correlation with surgical and pathologic findings  

International Nuclear Information System (INIS)

The primary aim was to evaluate delayed contrast-enhanced MRI in depicting perineural spread of hilar cholangiocarcinoma (CCC) and consequently to determine the capability of MRI/MRCP for staging CCC. Fifteen patients that underwent MRI/MRCP and surgical treatment were retrospectively included. Two radiologists evaluated MR images to assess delayed periductal enhancement, extent of bile duct stenosis, liver parenchymal and vascular involvement and presence of liver atrophy. An agreement between delayed enhancement of the bile duct walls and perineural neoplastic spread showed a very good correlation factor (0.93). The overall accuracy in detecting biliary neoplastic invasion was higher for delayed T1-weighted images (93.3%) than for the MRCP images (80%), and T1-delayed image increased the MR accuracy in assessing the neoplastic resectability (p < 0.05). MRI correctly predicted ...

2008-10-01

33

Fluid flow visualization with neutron radiography. [Using collimated beam of neutrons  

Energy Technology Data Exchange (ETDEWEB)

A technique was developed that permits fluid flow to be visualized even where the flow is completely shrouded by metal. The technique employs real-time neutron radiography, which is similar to x-ray radiography except a collimated beam of neutrons is used. Various combinations of neutron-opaque tracer materials were tested with neutron-transparent fluid. Neutron opaque tracers, such as solid particles, fluid droplets, and streaklines were imaged through metal walls as they convected in neutron-transparent ambient fluid. Visualization of bubbles/voids were evaluated for possible future applications. Surface-flow patterns were also imaged by using neutron-opaque tufts. These techniques were evaluated for image contrast, resolution, and the ability to accurately track fluid flow fields. The techniques were also modeled to optimize contrast in various flow configurations. Imaging ...

1991-01-01

34

Fluid flow visualization with neutron radiography  

International Nuclear Information System (INIS)

A technique was developed that permits fluid flow to be visualized even where the flow is completely shrouded by metal. The technique employs real-time neutron radiography, which is similar to x-ray radiography except a collimated beam of neutrons is used. Various combinations of neutron-opaque tracer materials were tested with neutron-transparent fluid. Neutron opaque tracers, such as solid particles, fluid droplets, and streaklines were imaged through metal walls as they convected in neutron-transparent ambient fluid. Visualization of bubbles/voids were evaluated for possible future applications. Surface-flow patterns were also imaged by using neutron-opaque tufts. These techniques were evaluated for image contrast, resolution, and the ability to accurately track fluid flow fields. The techniques were also modeled to optimize contrast in various flow configurations. Imaging ...

1764-01-01

35

MAPLE/HANARO type fuel element two-phase flow parameter measurement by real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

The objective of this work is the measurement of two-phase flow parameters to support development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR). A single element finned Fuel Element Simulator was used with R134a Freon flow. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distributions were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly limits any significant vibration and the ...

2002-07-01

36

MAPLE/HANARO type fuel element two-phase flow parameter measurement by real-time neutron radiography  

International Nuclear Information System (INIS)

The objective of this work is the measurement of two-phase flow parameters to support development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR). A single element finned Fuel Element Simulator was used with R134a Freon flow. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distributions were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly limits any significant vibration and the ...

2002-08-11

37

Finned fuel element two-phase flow parameter measurements using real-time neutron radiography  

International Nuclear Information System (INIS)

The measurement of two-phase flow parameters and development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR) is discussed in this paper. A single element finned Fuel Element Simulator (FES) was used with R134a Freon as the working fluid. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distribution were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly limits any significant vibration ...

2007-04-22

38

Finned fuel element two-phase flow parameter measurements using real-time neutron radiography  

International Nuclear Information System (INIS)

The measurement of two-phase flow parameters for development of constitutive relationships for the HANARO/MAPLE type finned fuel using Real-Time Neutron Radiography (RTNR) is discussed in this paper. A single element finned Fuel Element Simulator (FES) was used with Freon 134a as the working fluid. To observe the effect of a spacer device on void distribution, single pin tests were performed with and without a spacer present. By analyzing the RTNR images using image processing, the effects of the spacer on the time-averaged and instantaneous void fraction distribution were studied. For the experimental results without a spacer, the time-averaged local void distribution is radially asymmetric and the degree of void fluctuation increases with a decreasing frequency along the heated channel, where the observed asymmetry may be caused by flow induced vibration. For the experimental results with a spacer, the spacer clearly limits any significant ...

2008-02-01

39

Primary cutaneous Ewing's sarcoma/primitive neuroectodermal tumor manifesting numerous small and huge ulcerated masses: its complete remission by chemotherapy and magnetic resonance imaging findings  

International Nuclear Information System (INIS)

Extraskeletal Ewing's sarcoma (ES) and primitive neuroectodermal tumor (PNET) are widely regarded as clinically and histologically identical tumors which consist of small blue round cells. Extraskeletal ESs/PNETs usually occur in the deep soft tissues of the paraspinal region, chest wall, or lower extremities. However, superficially located cases, so-called cutaneous ESs/PNETs, are exceedingly rare, and the vast majority of the reported cases present as a single small mass. We present magnetic resonance imaging (MRI) findings and clinical course of a unique case of primary cutaneous ES/PNET presenting as numerous huge masses with severe ulceration on them. (orig.)

2010-06-01

40

Normalized noise power spectrum of full field digital mammography detector system  

International Nuclear Information System (INIS)

Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)

41

Normalized Noise Power Spectrum of Full Field Digital Mammography System  

International Nuclear Information System (INIS)

A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.

2010-01-05

42

Vessel wall MRI of the thoracic aorta: correlation to histology and transesophageal ultrasound. Preliminary results  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To visualise the vessel wall of the descending thoracic aorta using magnetic resonance imaging. To evaluate the diagnostic potential of tailored T{sub 1}-weighted sequences with contrast enhancement to assess systemic atherosclerotic disease. Methods: This study was performed on a clinical 1.5 Tesla scanner using a gradient strength of 30 mT/m and the phased array spine coil. A cadaver was examined to optimise a magnetic resonance imaging (MRI) protocol to evaluate atherosclerotic aortic wall disease. The acquired MR images were compared to gross specimens and histology. Subsequently seven patients who had undergone transesophageal ultrasound (TEU) with detailed assessment of the descending thoracic aorta were examined with MRI. The optimised protocol included untriggered and fat suppressed T{sub 2}-weighted turbo spin echo sequences and ECG-triggered and fat suppressed ...

2002-05-01

43

Combined peritoneography and computerized tomography for evaluating abdominal complications in patients undergoing continuous peritoneal dialysis  

International Nuclear Information System (INIS)

Continuous ambulatory peritoneal dialysis (CAPD) is a generally well-tolerated treatment. However, some patients exhibit such complications as to prevent the continuation of treatment. Peritonitis is the major problem, but the continuation of treatment may also be undermined by different complications, such as peritoneal leakage, hernia, catheter malfunctioning, and scrotal-penile edema; a careful investigation of the patient is always needed in such cases. From November 1985 to February 1990, we examined 20 patients, who had presented with different types of complications in the course of dialysis. Peritoneography demonstrated 3 cases of abdominal hernias, 2 cases of patency of the peritoneal-vaginal duct, and 2 cases of catheter obstruction. Peritoneal CT allowed the identification of leakage in 3 patients, while the combined use of the two techniques showed adhesions or pathologic peritoneal recesses in 7 cases. In 3 patients normal patterns ...

1985-11-01

44

Scatter measurements for optical cone-beam computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Both x-ray and optical cone-beam CT (CBCT) scanners are limited by scattered photons that contaminate the primary images. Transparent radiochromic gels and plastics are anticipated to produce less scattering than polymerization gels and hence result in reconstructed dose distributions with greater contrast and dynamic range. Four methods of scatter measurement were investigated to quantify scatter fractions using an in-house optical CBCT scanner. The methods consisted of generating either 'coin' shadows or primary beamlets in transmission images. The four methods generated similar results of 10% scatter fractions in gel transmission images for this particular scanner configuration with both leuco crystal violet and carbon black micelle gels. The scatter contributions were distributed as 5% from micelle gel, 2% from Teflon wall, 2% from refractive index matching liquid and 1% other ...

2009-05-01

45

MR imaging of hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Magnetic resonance (MR) images of 18 cases of hilar cholangiocarcinoma were evaluated to compare the effectiveness of Gd-DTPA with that of high dose contrast enhancement computed tomography (HCE-CT) in detecting the primary tumor. The primary tumor was demonstrated as having slightly low intensity compared with liver parenchyma and high intensity compared with the delated bile duct on T1-weighted images. In contrast, MRI using Gd-DTPA, which was carried out in five cases, revealed intense enhancement of the tumor. As the differentiation between cholangiocarcinoma and dilated bile duct was difficult, it was concluded that the use of Gd-DTPA improves the efficacy of MRI in diagnosing cholangiocarcinoma. Gd-DTPA was also effective in differentiating the growth pattern of the tumor: the infiltrating type was demonstrated as thickening of the wall of the bile duct, the polypoid type as a soft tissue mass in the bile duct. ...

46

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas  

International Nuclear Information System (INIS)

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. ...

2003-03-01

47

MRI-based N-staging in esophageal cancer  

International Nuclear Information System (INIS)

Purpose: For planning the therapeutic strategies and estimating the prognosis in esophageal cancer, N-staging is very important. To date, MRI still is of minor importance as imaging modality of the mediastinum despite promising developments in the past, like ECG-gating or 'averaging' sequences, e.g. LOTA (Long-term averaging), which facilitate mediastinal and thoracic MR-imaging. In a prospective approach, the value of MRI based N-staging was examined with respect to LOTA-sequences. Material and Methods: Within from weeks prior to esophagectomy, standardized MRI of the esophagus was performed in 15 patients (10 squamous-cell-carcinomas and 5 adenocarcinomas) using a 1.5 T whole body scanner. Imaging quality was classified based on depiction of aortic wall or tracheal wall layers. Criteria for malignant infiltration were a diameter of more than 15 mm or a round appearance of a lymph ...

2002-10-01

48

A study of image-guided radiotherapy of bladder cancer based on lipiodol injection in the bladder wall  

Energy Technology Data Exchange (ETDEWEB)

Purpose. We have tested a procedure of focal injection of the contrast medium Lipiodol as a fiducial marker for image-guided boost of the tumor in bladder cancer radiotherapy (RT). In this study, we have evaluated the feasibility and the safety of the method as well as the inter- and intra-fraction shift of the bladder tumor. Materials and methods. Five patients with muscle invasive urinary bladder cancer were included in the study. Lipiodol was injected during flexible cystoscopy into the submucosa of the bladder wall at the periphery of the tumor or the post resection tumor-bed. Cone-beam CT (CBCT) scans were acquired daily throughout the course of RT. Results. Lipiodol demarcation of the bladder tumor was feasible and safe with only a minimum of side effects related to the procedure. The Lipiodol spots were visible on CT and CBCT scans for the duration of the RT course. More than half of all the treatment fractions required a geometric shift ...

2010-10-15

49

Reactions of the inner surface of carbon nanotubes and nanoprotrusion processes imaged at the atomic scale  

British Library Electronic Table of Contents (United Kingdom)

Although the outer surface of single-walled carbon nanotubes (atomically thin cylinders of carbon) can be involved in a wide range of chemical reactions, it is generally thought that the interior surface of nanotubes is unreactive. In this study, we show that in the presence of catalytically active atoms of rhenium inserted into nanotubes, the nanotube sidewall can be engaged in chemical reactions from the inside. Aberration-corrected high-resolution transmission electron microscopy operated at 80?keV allows visualization of the formation of nanometre-sized hollow protrusions on the nanotube sidewall at the atomic level in real time at ambient temperature. Our direct observations and theoretical modelling demonstrate that the nanoprotrusions are formed in three stages: (i) metal-assisted d...

2011-01-01

50

Radiometric measurement of temperature distributions in solar cavity receivers  

Energy Technology Data Exchange (ETDEWEB)

An engineering tool incorporating a scanning infrared radiometer, an image digitizer, a microcomputer, and the software to drive the system was developed to allow remote mapping of the temperature distribution in solar cavity receivers. Using enclosure analysis, the infrared image processing program extracts the irradiance map from the radiosity map of the cavity to yield an emissive power map. Using the calibration curve of the radiometer and the emissivity of the surface of the cavity, the emissive power map is transformed into a temperature map. The system was tested by comparing its calculated temperatures to temperatures measured by thermocouples at several locations on the surfaces of heated model cavity receivers. The average relative error for the cavities ranged from 4.6%--34.9%, with the relative error on the base usually less than half that on the wall. Some work was also carried out to compensate the detected ...

1989-03-01

51

Pre-transitional disk nature of the AB Aur disk  

CERN Document Server

The disk around AB Aur was imaged and resolved at 24.6\\,$\\mu$m using the Cooled Mid-Infrared Camera and Spectrometer on the 8.2m Subaru Telescope. The gaussian full-width at half-maximum of the source size is estimated to be 90 $\\pm$ 6 AU, indicating that the disk extends further out at 24.6\\,$\\mu$m than at shorter wavelengths. In order to interpret the extended 24.6\\,$\\mu$m image, we consider a disk with a reduced surface density within a boundary radius $R_c$, which is motivated by radio observations that suggest a reduced inner region within about 100 AU from the star. Introducing the surface density reduction factor $f_c$ for the inner disk, we determine that the best match with the observed radial intensity profile at 24.6\\,$\\mu$m is achieved with $R_c$=88 AU and $f_c$=0.01. We suggest that the extended emission at 24.6\\,$\\mu$m is due to the enhanced emission from a wall-like structure at the boundary radius ...

2010-01-01

52

Ideal Magnetohydrodynamics Stability Spectrum with a Resistive Wall  

Energy Technology Data Exchange (ETDEWEB)

We show that the eigenvalue equations describing a cylindrical ideal magnetophydrodynamicsw (MHD) plasma interacting with a thin resistive wall can be put into the standard mathematical form: ??? = ??? ?. This is accomplished by using a finite element basis for the plasma, and by adding an extra degree of freedom corresponding to the electrical current in the thin wall. The standard form allows the use of linear eigenvalue solvers, without additional interations, to compute the complete spectrum of plasma modes in the presence of a surrounding restrictive wall at arbitrary separation. We show that our method recovers standard results in the limits of (1) an infinitely resistive wall (no wall), and (2) a zero resistance wall (ideal wall).

2008-05-22

54

Numerical study of the impingement of a supersonic, axisymmetric jet on a flat plate  

International Nuclear Information System (INIS)

A numerical method for studying the flow field of an under-expanded axis-symmetric jet created by a converging-diverging nozzle and impinging on a flat plate is presented. The calculation domain of interest is a region that contains all the features of the jet that leaves the nozzle and impinges onto the plate. Axial symmetry of the domain allows a reduced 2-dimensional model to be used. FLUENT software is utilized to solve the continuity, momentum and energy equations using a coupled implicit scheme. The ideal-gas law is used to determine the gas density along with a k-#epsilon# turbulence model with a special modification to account for compressibility effects. In addition, the temperature dependency of viscosity has been taken into consideration. A number of different modeling techniques are investigated including different approximations to account for the flow inside the nozzle. Performance of non-equilibrium wall functions for near-wall ...

55

Multislice helical CT in the diagnosis of hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Objective: To investigate the value ofMSCT in observing the direct findings of hilar cholangiocarcinoma1Methods Multislice helical CT studies were performed on the upper abdomen in 19 consecutive patientswith painless jaundice1 Precontrast and dynamic contrast enhanced (25 s phase and 60 s phase) scanswere conducted, and 3D imageswere reconstructed using enhanced raw data in 15 cases1 The direct CT findings of hilar cholangiocarcinoma were studied by three radiologists respectively in a 32scale strategy1 The morphological features and extension of bile duct involvement by hilar cholangiocarcinoma were analyzed1 All the 19 caseswere pathologically p roved as hilar cholangiocarcinoma by surgery (15 cases) and ERCP ( 4 cases) 1 Results The direct findings and extension of hilar cholangiocarcinoma could be demonstrated in 14 out of 15 3D reconstruction images, 8 out of 19 in 25 s phase, and 7 out of 19 in 60 s phase of contrast enhancement scans, respectively ( P < ...

2005-11-01

56

Aortic non communicating dissections. A study with helical CT  

International Nuclear Information System (INIS)

The evaluate the signs of aortic intramural hematoma with helical CT and the diagnostic role of this technique in patients with this condition. It was reviewed the CT findings of 396 patients submitted to emergency examinations for suspected aortic dissection from 1995 to 1999. Only 18 patients (6 women and 12 men) had CT signs of aortic intramural hematoma. Helical CT studies were carried out with the following parameters: slice thickness 10 mm, reconstruction index 10, feed 1.5 mm, conventional algorithm with minimum values of 130 kV and 125mA. All patients were examined with dynamic contrast-enhanced CT, before and after a power injection of 130 mL ionic contrast material. It was studied: hematoma localization and longitudinal extension; thickness and density of aortic wall; presence and location of intimal calcifications; integrity of intimal wall; hemo mediastinum and/or hemo thorax. Aortic wall thickening appeared as ...

2000-09-01

57

Atlas of nuclear medicine imaging  

Energy Technology Data Exchange (ETDEWEB)

An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)

1981-01-01

58

Role of nuclear medicine and magnetic resonance imaging in cardiac diagnostics; Rolle der nuklearmedizinischen Verfahren und der Magnetresonanztomographie in der kardialen Diagnostik  

Energy Technology Data Exchange (ETDEWEB)

Nuclear medicine and magnetic resonance imaging (MRI) are widely used in cardiac diagnostics. Both techniques have been carefully evaluated and are equivalent for the assessment of regional and global wall motion as well as the evaluation of ejection fraction and cardiac volumes, though MRI is herein currently seen as gold standard. For evaluation of myocardial perfusion, extensive data exist for nuclear imaging, that, next to high diagnostic accuracy for evaluation of coronary artery disease, show incremental prognostic information and allow for independent risk stratification. Because of rapid technical advance, myocardial perfusion imaging has also become feasible with cardiac MRI. Results of recent studies are promising, but the data are few compared to perfusion scintigraphy. For viability assessment in patients with ischemic cardiomyopathy, positron emission tomography (PET) with FDG is currently ...

2003-12-01

59

Subcellular Localization of Expansin mRNA in Xylem Cells12  

UK PubMed Central (United Kingdom)

Terminal differentiation of many vascular cells involves cell wall changes. Cells first elongate their primary wall, then lay down a lignified secondary wall, which is often followed by digestion of...Full Text Available

2000-06-01

60

Gravitational Waves from Collapsing Domain Walls  

CERN Document Server

We study the production of gravitational waves from cosmic domain walls created during phase transition in the early universe. We investigate the process of formation and evolution of domain walls by running three dimensional lattice simulations. If we introduce an approximate discrete symmetry, walls become metastable and finally disappear. We calculate the spectrum of gravitational waves produced by collapsing metastable domain walls. Extrapolating the numerical results, we find the signal of gravitational waves produced by domain walls whose energy scale is around 10^10-10^12GeV will be observable in the next generation gravitational wave interferometers.

2010-01-01

61

Phase- and size-adjusted CT cut-off for differentiating neoplastic lesions from normal colon in contrast-enhanced CT colonography  

Energy Technology Data Exchange (ETDEWEB)

A computed tomography (CT) cut-off for differentiating neoplastic lesions (polyps/carcinoma) from normal colon in contrast-enhanced CT colonography (CTC) relating to the contrast phase and lesion size is determined. CT values of 64 colonic lesions (27 polyps <10 mm, 13 polyps {>=}10 mm, 24 carcinomas) were determined by region-of-interest (ROI) measurements in 38 patients who underwent contrast-enhanced CTC. In addition, the height (H) of the colonic lesions was measured in CT. CT values were also measured in the aorta (A), superior mesenteric vein (V) and colonic wall. The contrast phase was defined by xA + (1 - x)V using x as a weighting factor for describing the different contrast phases ranging from the pure arterial phase (x=1) over the intermediate phases (x=0.9-0.1) to the pure venous phase (x=0). The CT values of the lesions were correlated with their height (H), the different phases (xA + (1 - x)V) and the ratio [xA + (1 - x)V]/H. The CT ...

2004-12-01

62

Field driven ferromagnetic phase evolution originating from the domain boundaries in antiferromagnetically coupled perpendicular anitsotropy films  

Energy Technology Data Exchange (ETDEWEB)

Strong perpendicular anisotropy systems consisting of Co/Pt multilayer stacks that are antiferromagnetically coupled via thin Ru or NiO layers have been used as model systems to study the competition between local interlayer exchange and long-range dipolar interactions [1,2]. Magnetic Force Microscopy (MFM) studies of such systems reveal complex magnetic configurations with a mix of antiferromagnetic (AF) and ferromagnetic (FM) phases. However, MFM allows detecting surface stray fields only and can interact strongly with the magnetic structure of the sample, thus altering the original domain configuration of interest [3,4]. In the current study they combine magnetometry and state-of-the-art soft X-ray transmission microscopy (MXTM) to investigate the external field driven FM phase evolution originating from the domain boundaries in such antiferromagnetically coupled perpendicular anisotropy films. MXTM allows directly imaging the perpendicular component of the ...

2008-05-01

63

The Structure of Plant Cell Walls  

UK PubMed Central (United Kingdom)

The molecular structure, chemical properties, and biological function of the xyloglucan polysaccharide isolated from cell walls of suspension-cultured sycamore (Acer pseudoplatanus)...Full Text Available

1973-01-01

64

Constraints on target chamber first wall and target designs that will enable NIF debris shields to survive  

CERN Document Server

Constraints on target chamber first wall and target designs that will enable NIF debris shields to survive

1999-01-01

65

MRT of the abdomen in combination with enteroclysis in Crohn disease with oral and intravenous Gd-DTPA  

International Nuclear Information System (INIS)

60 patients between 17 and 72 years of age were investigated. First, an enteroclysis was performed in typical manner. The applicated methylcellulosis was blended with positive oral MR contrast media (Magnevist oral, Schering). After enteroclysis, MRI of the abdomen was performed using T1- and T2-weighted breathhold sequences (Flash 2D pre- and postcontrast and TSE) in axial and coronal planes. The length of the affected bowel and the stenosis seen with enteroclysis correlated well with the visible thickening of the small bowel wall and the stenosis seen in MRI. Using MRI, additional findings could be obtained in 28 patients, such as fistulas, abscesses or a hydronephrosis, or a better assessment of the stenosis was possible with MRI, because of the avoidance of overshadowing of the affected bowel loop with MRI. A brilliant MR-tomographic imaging of the small bowel is possible under the condition, that the small bowel contrast is optimal. The ...

66

MRI in pleural diseases  

International Nuclear Information System (INIS)

The MRI and CT appearances in 48 patients with histologically confirmed benign and malignant pleural abnormalities were compared retrospectively. Abnormal pleural changes were shown in 47 out of the 48 patients by high signal intensity of the pleura in T_2-weighted sequences and in contrast enhanced T_1-weighted sequences on MRI. CT showed abnormalities in 45 out of 48 patients. Delineation of pleural and pulmonary changes by CT was possible in 13 out of 23 cases, and pleural disease from effusions in 15 out of 28 cases. T_2-weighted MRI was successful in 14 out of 23 and 4 out of 28 cases, respectively. T_1-weighted images after contrast were successful in 20 out of 23 and 22 out of 28 cases, respectively. Indications of malignant pleural disease were the presence of mediastinal or circumferential involvement or involvement of the entire pleura, thickness of more than 10 mm and nodular changes. The most reliable sign of malignancy was infiltration of the thoracic ...

67

Computed Tomography in staging and follow-up of thoracic Hodgkin's diseases  

International Nuclear Information System (INIS)

As yet, the role of Computed Tomography (CT) as a routine imaging technique in the staging and follow-up of thoracic Hodgkin's disease has not been assessed. The authors reported the results obtained in 120 patients affected with thoracic Hodgkin's disease, staged and followed by means af chest X-rays and CT. CT better identified intrathoracic involvement of mediastinal nodes, of lung parenchyma, of pleura, and of pericarcial and chest walls in 54/120 patients (45%), with staging modifications in 18 (15%) of them only. Treatment was changed only in 12 patients (19%) where radiation therapy had been planned. The clinical value of the additional information yielded by CT was especially evident in the follow-up: CT allowed the correct evaluation of persistent/ recurrent disease in 51/117 patients (43.5%), a figure high enough to suggest the use of CT in the routive follow-up of patients affected with thoracic Hodgkin's disease.

1990-01-01

68

Spin-resolved magnetic studies of focused ion beam etched nano-sized magnetic structures  

International Nuclear Information System (INIS)

Scanning ion microscopy with polarization analysis (SIMPA) is used to study the spin-resolved surface magnetic structure of nano-sized magnetic systems. SIMPA is utilized for in situ topographic and spin-resolved magnetic domain imaging as well as for focused ion beam (FIB) etching of desired structures in magnetic or non-magnetic systems. Ultra-thin Co films are deposited on surfaces of Si(1 0 0) substrates, and ultra-thin, tri-layered, bct Fe(1 0 0)/Mn/bct Fe(1 0 0) wedged magnetic structures are deposited on fcc Pd(1 0 0) substrates. SIMPA experiments clearly show that ion-induced electrons emitted from magnetic surfaces exhibit non-zero electron spin polarization (ESP), whereas electrons emitted from non-magnetic surfaces such as Si and Pd exhibit zero ESP, which can be used to calibrate sputtering rates in situ. We report on new, spin-resolved magnetic microstructures, such as magnetic 'C' states and magnetic vortices, found at surfaces of FIB patterned ...

2005-04-01

69

Estimation of a stress field in the earth`s crust using drilling-induced tensile fractures observed at well WD-1 in the Kakkonda geothermal field; Kakkonda WD-1 sei de kansokusareta drilling induced tensile fracture ni yoru chikaku oryokuba no suitei  

Energy Technology Data Exchange (ETDEWEB)

This paper describes estimation of a stress field in the earth`s crust in the Kakkonda geothermal field. Formation micro imager (FMI) logging known as a crack detecting logging was performed in the well WD-1. This FMI logging has made observation possible on cracks along well axis thought to indicate size and direction of the crust stress, and drilling-induced tensile fractures (DTF). It was verified that these DTFs are generated initially in an azimuth determined by in-situ stress (an angle up to the DTF as measured counterclockwise with due north as a starting point, expressed in {theta}) in the well`s circumferential direction. It was also confirmed that a large number of cracks incline at a certain angle to the well axis (an angle made by the well axis and the DTF, expressed in {gamma}). The DTF is a crack initially generated on well walls as a result of such tensile stresses as mud pressure and thermal stress acting on the well ...

1997-05-27

70

Optical Images Due to Lenses and Mirrors  

Science.gov (United States)

... Title : Optical Images Due to Lenses and Mirrors. ... Abstract : The properties of real and virtual images formed by lenses and mirrors are reviewed. ...

71

In vitro MRI of brain development  

International Nuclear Information System (INIS)

In this review, we demonstrate the developmental appearance, structural features, and reorganization of transient cerebral zones and structures in the human fetal brain using a correlative histological and MRI analysis. The analysis of postmortem aldehyde-fixed specimens (age range: 10 postovulatory weeks to term) revealed that, at 10 postovulatory weeks, the cerebral wall already has a trilaminar appearance and consists of: (1) a ventricular zone of high cell-packing density; (2) an intermediate zone; (3) the cortical plate (in a stage of primary consolidation) with high MRI signal intensity. The anlage of the hippocampus is present as a prominent bulging in the thin limbic telencephalon. The early fetal telencephalon impar also contains the first commissural fibers and fornix bundles in the septal area. The ganglionic eminence is clearly visible as an expanded continuation of the proliferative ventricular zone. The basal ganglia showed an initial aggregation of ...

2006-02-01

73

MAGNETIC RESONANCE IMAGING DEVICE  

J-STORE (Japan)

Full Text Available

2010-08-31

74

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas; CT und MRT des erworbenen Cholesteatoms: Prae- und postoperative Bildgebung  

Energy Technology Data Exchange (ETDEWEB)

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. ...

2003-03-01

75

Transfer of lead through the rats intestinal wall  

International Nuclear Information System (INIS)

... females in vitro intestines lead 203 mucous membranes radionuclide kinetics

78

In-situ maintenance of low-Z limiters in reactors  

Energy Technology Data Exchange (ETDEWEB)

In a reactor environment, the surface of a limiter or wall is primarily determined by the mechanism of erosion and deposition of surface material. It should be possible to use pellet injection to reduce net erosion to zero everywhere if low-Z materials are used for the surface. Erosion rates can, in general, be minimized by large area limiters and high plasma temperatures, which transmit power to the walls with less sputtering. Under ideal steady state conditions the wall surface is dominated by metallurgical effects in the wall.

1980-01-01

81

Complex Abdominal Wall Repair  

Medline Plus

... presentation will be archived on the OR-Live website. 00:46:02 ANNOUNCER: This has been a ...

83

Synthesis and PET imaging of the benzodiazepine receptor tracer [N-methyl-"1"1C]iomazenil  

International Nuclear Information System (INIS)

The central benzodiazepine receptor tracer [N-methyl-"1"1C]iomazenil (Ro 16-0154) was synthesized by alkylation of the desmethyl precursor noriomazenil with ["1"1C]methyl iodide. The ["1"1C]CH_3I (prepared by reduction of ["1"1C]CO_2 with LiAlH_4 followed by reaction with HI) was reacted with noriomazenil inN,N -dimethylformamide and Bu_4N"+OH"- for 1 min at 80 deg. C and purified by HPLC (C_1_8, 34% CH_3CN/H_2O, 7 mL/min). The product was obtained with synthesis time 35 #+-# 5 min (mean #+-# SD, n = 7), radiochemical yield (EOB) 36 #+-# 16%, radiochemical purity 99 #+-# 1%, and specific activity 5100 #+-# 2800 mCi/#mu#mol. Absorbed radiation doses were calculated from previously acquired human biodistribution data. The urinary bladder wall received the highest dose (0.099 mGy/MBq) for 4.8 h voiding interval and the effective dose equivalent was 0.015 mSv/MBq. After i.v. injection of ["1"1C]iomazenil in an adult baboon or healthy human volunteer, radioactivity ...

1995-07-01

84

Results of the remote sensing feasibility study for the uranium hexafluoride storage cylinder yard program  

Energy Technology Data Exchange (ETDEWEB)

The US DOE manages the safe storage of approximately 650,000 tons of depleted uranium hexafluoride remaining from the Cold War. This slightly radioactive, but chemically active, material is contained in more than 46,000 steel storage cylinders that are located at Oak Ridge, Tennessee; Paducah, Kentucky; and Portsmouth, Ohio. Some of the cylinders are more than 40 years old, and approximately 17,500 are considered problem cylinders because their physical integrity is questionable. These cylinders require an annual visual inspection. The remainder of the 46,000-plus cylinders must be visually inspected every four years. Currently, the cylinder inspection program is extremely labor intensive. Because these inspections are accomplished visually, they may not be effective in the early detection of leaking cylinders. The inspection program requires approximately 12--14 full-time-equivalent (FTE) employees. At the cost of approximately $125K per FTE, this translates to $1,500K per annum just ...

1997-02-01

85

Physical Modelling of Axisymmetric Turbulent Impinging Jets as used within the Nuclear Industry for Mobilisation of Sludges  

Energy Technology Data Exchange (ETDEWEB)

The impingement of a fluid jet onto a surface has broad applications across many industries. Within the UK nuclear industry, during the final stages of fuel reprocessing, impinging fluid jets are utilised to mobilise settled sludge material within storage tanks and ponds in preparation for transfer and ultimate immobilisation through vitrification. Despite the extensive applications of impinging jets within the nuclear and other industries, the study of two-phase, solid loaded, impinging jets is limited, and generally restricted to computational modelling. Surprisingly, very little fundamental understanding of the turbulence structure within such fluid flows through experimental investigation is found within the literature. The physical modelling of impinging jet systems could successfully serve to aid computer model validation, determine operating requirements, evaluate plant throughput requirements, optimise process operations and support design. Within this project a method is ...

2008-07-01

86

Evaluation of the 1Shot Phantom dedicated to the mammography system using FCR  

International Nuclear Information System (INIS)

Currently daily quality control (QC) tests for mammography systems are generally evaluated by using visual analysis phantoms, which of course means subjective measurement. In our study, however, we evaluated a novel digital phantom, the 1Shot Phantom M plus (1Shot Phantom), together with automatic analysis software dedicated for mammography systems using Fuji computed radiography (FCR). The digital phantom enables objective evaluation by providing for actual physical measurement rather than subjective visual assessment. We measured contrast to noise ratio (CNR), image receptor homogeneity, missed tissue at chest wall side, modulation transfer function (MTF), and geometric distortion utilizing the 1Shot Phantom. We then compared the values obtained using the 1Shot Phantom with values obtained from the European guidelines and International Electrotechnical Commission (IEC) standards. In addition, we evaluated the convenience of using the digital ...

2009-07-01

87

Influence of surface heat flux ratio on heat transfer augmentation in square channels with parallel, crossed, and V-shaped angled ribs  

Science.gov (United States)

The paper investigates the effect of the wall heat flux ratio on the local heat transfer augmentation in a square channel with two opposite in-line ribbed walls for Reynolds numbers from 15,000 to 80,000. The square channel composed of 10 isolated copper sections has a length-to-hydraulic diameter ratio of 20. The rib height-to-hydraulic diameter ratio is 0.0625 and the rib pitch-to-height ratio equals 10. Six ribbed side to smooth side wall heat flux ratios are studied for four rib orientations. The results show that the ribbed side wall heat transfer augmentation increases with increasing ribbed side to smooth side wall heat flux ratios, but the reverse is true for the smooth side wall heat transfer augmentation. The average heat transfer augmentation of the ribbed side and smooth side wall decreases slightly with increasing ...

1992-10-01

90

Java Image I/O for VICAR, PDS, and ISIS  

Science.gov (United States)

This library, written in Java, supports input and output of images and metadata (labels) in the

2011-01-01

91

Involvement of the chest and abdominal wall as a rare manifestation in Hodgkin's disease  

Energy Technology Data Exchange (ETDEWEB)

Radiological findings of chest and abdominal wall involvement in Hodgkin's disease are reported. This manifestation was diagnosed in one patient in the primary staging and in two patients during the course of the disease. Typical radiological findings are soft tissue masses in the chest and abdominal wall, in two cases with continous tumor growth of enlarged mediastinal lymphnodes into the anterior chest wall. The axial computed tomography is the best method to evaluate the extent of chest and abdominal wall involvement in Hodgkin's disease.

1983-03-01

92

A non-local approach for image super-resolution using intermodality priors ?  

UK PubMed Central (United Kingdom)

Image enhancement is of great importance in medical imaging where image resolution remains a crucial point in many image analysis algorithms. In this paper, we investigate brain hallucination...Full Text Available

2010-08-01

93

Revisited the mathematical derivation wall thickness measurement of pipe for radiography  

Energy Technology Data Exchange (ETDEWEB)

Wall thickness measurement of pipe is very important of the structural integrity of the industrial plant. However, the radiography method has an advantage because the ability of penetrating the insulated pipe. This will have economic benefit for industry. Moreover, the era of digital radiography has more advantages because the speed of radiographic work, less exposure time and no chemical used for film development. Either the conventional radiography or digital radiology, the wall thickness measurement is using the tangential radiography technique (TRT). In case, of a large diameter, pipe (more than inches) the determination maximum penetration wall thickness must be taken into the consideration. This paper is revisited the mathematical derivation of the determination of wall thickness measurement based on tangential radiography technique (TRT). The mathematical approach used in this derivation is the ...

2007-07-01

94

Applicability of structural wall test results to seismic design of nuclear facilities  

International Nuclear Information System (INIS)

A review of tests on earthquake-resistant reinforced concrete structural walls is presented. Laboratory tests of isolated walls and construction joints are discussed. Where appropriate, design recommendations are given. The review indicates only few experimental data are available for short walls which are directly applicable to nuclear power plant design. In particular, tests of short rectangular walls subjected to load reversals are needed. Tests are also needed to determine the damping and frequency characteristics of cracked short walls. Analytical and experimental results should be correlated so that the hysteretic response observed in tests can be realistically related to the analytical response 'demand' of nuclear power plant structures. (Auth.).

95

A task-based usage strategy for control centre wall displays  

Energy Technology Data Exchange (ETDEWEB)

This paper summarizes the findings from an exploratory definition of a usage strategy for multiple control centre wall displays in CANDU nuclear power plants. Wall displays are defined as large sized, vertically oriented display surfaces that may be positioned in various locations about a control room to support user information needs. The paper begins by discussing the need for a usage strategy for all control room information resources, and then reviews the history in wall display implementation and usage in nuclear power plant control rooms. The balance of the paper discusses the approach used in characterization and review of control room task information needs and definition of a wall display usage strategy. The paper concludes by outlining some of the possible impacts on future control room design and operations that the introduction of wall displays may imply. (author)

2005-07-01

96

View larger image for ISS022-E-26137 - Earth Sciences and Image ...  

Science.gov (United States)

The Asarco-Mission complex (image left) is an active producer of copper and molybdenum (important in making steel and other metal alloys), ...

97

Digital processing to improve image quality in real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...

1985-01-01

98

Digital processing to improve image quality in real-time neutron radiography  

International Nuclear Information System (INIS)

Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...

1985-01-01

99

Advances in Imaging of Vertebral and Spinal Cord Injury  

UK PubMed Central (United Kingdom)

Background/Objectives:Imaging technology is an important part of the diagnosis and management of spinal trauma. Indications and findings in post-traumatic imaging of the vertebral...Full Text Available

2010-04-01

100

3 - NASA Technical Report Server (NTRS)  

Science.gov (United States)

performs Gaussian pyramid operation on an image performs expand pyramid operation on an image mosaic two images using 'reduce' and 'expand' pyramid ...

101

(Hadamard transform imaging)  

Science.gov (United States)

This report describes the design of, and image reconstruction capacity of a Hadamard Raman Microscopic imager. Microscopy of benzoic acid and graphite electrodes, as well as electrophoretic blotting, are described. (CBS)

1990-01-01

102

Walled-off pancreatic necrosis  

UK PubMed Central (United Kingdom)

Walled-off pancreatic necrosis (WOPN), formerly known as pancreatic abscess is a late complication of acute pancreatitis. It can be lethal, even though it is rare. This critical review provides an overview...Full Text Available

2010-04-14

103

Thermal energy considerations on solar cavity wall building  

Energy Technology Data Exchange (ETDEWEB)

The dwelling is equipped with solar collectors which heat the air circulating in the cavity walls and the space beneath the floors. The thermal aspects of such a building are described. Heat balance, losses, heating by the sun in different seasons are described. Different measures taken to reduce the energy losses are described.

1983-02-01

104

The Candida albicans Dse1 Protein Is Essential and Plays a Role in Cell Wall Rigidity, Biofilm Formation, and Virulence  

UK PubMed Central (United Kingdom)

The fungal pathogen Candida albicans is one of the leading causative agents of death in immunocompromised individuals. It harbors an arsenal of cell wall anchored factors that are implicated...Full Text Available

2011-01-01

105

Sealant tests to control radon emanation in a uranium mine. Open file report sep 79-dec 81  

International Nuclear Information System (INIS)

This report describes a field-test program to determine the effectiveness of a polymeric wall sealant to reduce the escape of naturally occurring radioactive gas radon from the walls of an underground uranium mine into the ventilation air.

106

Pretreatment with the gram-positive bacterial cell wall molecule peptidoglycan improves bacterial clearance and decreases inflammation and mortality in mice challenged with Pseudomonas aeruginosa  

UK PubMed Central (United Kingdom)

The objective of this study was to determine if inflammatory tolerance and enhancement of innate immune function could be induced by the gram-positive cell wall component peptidoglycan (PGN)....Full Text Available

2008-10-01

107

Poland's anomaly. Natural history and long-term results of chest wall reconstruction in 33 patients.  

UK PubMed Central (United Kingdom)

Poland's anomaly is an uncommon congenital aberration of the chest wall characterized by absence of the pectoralis major muscle and other nearby musculoskeletal components. In this series, a wide spectrum...Full Text Available

1988-12-01

108

Mapping strain exerted on blood vessel walls using deuterium double-quantum-filtered MRI  

UK PubMed Central (United Kingdom)

A technique is described for displaying distinct tissue layers of large blood vessel walls as well as measuring their mechanical strain. The technique is based on deuterium double-quantum-filtered (DQF)...Full Text Available

1998-04-14

109

Latent Tricuspid Valve Rupture after Motor Vehicle Accident and Routine Echocardiography in All Chest-Wall Traumas  

UK PubMed Central (United Kingdom)

Blunt chest-wall trauma is common; however, resultant tricuspid valve rupture is rare and can be subtle in its presentation. Transthoracic echocardiography plays a key role in diagnosis.Herein,...Full Text Available

2009-01-01

110

In-vivo coronary flow profiling based on biplane angiograms: influence of geometric simplifications on the three-dimensional reconstruction and wall shear stress calculation  

UK PubMed Central (United Kingdom)

BackgroundClinical studies suggest that local wall shear stress (WSS) patterns modulate the site and the progression of atherosclerotic lesions. Computational fluid dynamics (CFD)...Full Text Available

111

Ewing's sarcoma: a neuroectodermal tumor of the chest wall  

International Nuclear Information System (INIS)

Ewing's sarcoma is the second most common malignant bone tumor in children and young adults. It is most prevalent between the ages of 10 and 15 years. There are present two cases of Ewing's sarcoma of the chest wall. The clinical, radiological and pathological features are described and the therapeutic options are discussed. (Author)

112

Effects of Multivalent Cations on Cell Wall-Associated Acid Phosphatase Activity  

UK PubMed Central (United Kingdom)

Primary cell walls, free from cytoplasmic contamination were prepared from corn (Zea mays L.) roots and potato (Solanum tuberosum) tubers. After EDTA treatment, the...Full Text Available

1988-09-01

113

A Potential Elastohydrodynamic Origin of Load-Support and Coulomb-Like Friction in Lung/Chest Wall Lubrication  

UK PubMed Central (United Kingdom)

BackgroundDuring normal breathing, the mesothelial surfaces of the lung and chest wall slide relative to one another. Experimentally, the shear stresses induced by...Full Text Available

2008-10-01

114

A Model for Predicting Ionic Equilibrium Concentrations in Cell Walls 1  

UK PubMed Central (United Kingdom)

Purified cell walls were prepared from roots of Horse bean (Vicia faba L., var. minor) and Yellow Lupine (Lupinus luteus L.). Two methods were used:...Full Text Available

1981-08-01

115

A General Model of the Resistive Wall Instability in Linear Accelerators  

Energy Technology Data Exchange (ETDEWEB)

A general model for wakefield-generated instabilities in linear accelerators, originally developed for cumulative beam breakup [1], is applied to the resistive wall instability. The general solution for various bunch charge distributions and application to various accelerator configurations are presented.

2007-01-08

116

Single-Walled Carbon Nanotubes Targeted to the Tumor ...  

Science.gov (United States)

... 1981. Retention of diphenyls, terphenyls, phenylalkanes and fluorene on graphitized thermal carbon black. Chromatographia 14:510-514. ...

2009-09-01

118

Physical and Computational Investigation of the Wall Pressure ...  

Science.gov (United States)

... Although other authors had made cross-spectral density measurements, Corcos pointed to the importance of this function as indicative of the true ...

1990-04-26

120
122

Simple fractal method of assessment of histological images for application in medical diagnostics  

UK PubMed Central (United Kingdom)

We propose new method of assessment of histological images for medical diagnostics. 2-D image is preprocessed to form 1-D landscapes or 1-D signature of the image contour and then their complexity is...Full Text Available

123
130

Images of photoreceptors in living primate eyes using adaptive optics two-photon ophthalmoscopy  

UK PubMed Central (United Kingdom)

In vivo two-photon imaging through the pupil of the primate eye has the potential to become a useful tool for functional imaging of the retina. Two-photon excited fluorescence images...Full Text Available

131

Image Engine: an object-oriented multimedia database for storing, retrieving and sharing medical images and text.  

UK PubMed Central (United Kingdom)

This paper describes Image Engine, an object-oriented, microcomputer-based, multimedia database designed to facilitate the storage and retrieval of digitized biomedical still images, video, and text...Full Text Available

1993-01-01

139

Adaptive Image Processing A Computational Intelligence Perspective  

CERN Document Server

Adaptive image processing is one of the most important techniques in visual information processing, especially in early vision such as image restoration, filtering, enhancement, and segmentation. This work focuses on applications of advanced CI techniques in image processing applications

2009-01-01

140

Investigation of respiratory-dependent movements of pulmonary space-occupying lesions with MRI; Untersuchung der atemabhaengigen Bewegungen pulmonaler Raumforderungen mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Parallel imaging and echo sharing techniques have markedly reduced the acquisition times for MRI of large volumes. Dynamic 2 and 3-dimensional data sets of the chest with high temporal resolution (up to 10 images/s with single slice and 2 volume/s) allow an analysis of respiratory motion of the lungs and tumors. Time-resolved 2D series in preselected planes can be used to observe respiratory motion during free breathing or after respiratory commands, e.g. to exclude chest wall invasion by a tumor or for diagnosing impairment of respiratory mechanics. Time-resolved 3D-series (4D-MRI) allow monitoring of the spatial displacement of the lungs and tumors as a whole volume. Present limitations such as an overestimation of tumor size and an underestimation of displacement due to a limited temporal resolution are expected to be overcome with further technical developments. However, 4D-MRI already appears to be the appropriate tool ...

2009-08-15

141

Unsteady flow of an incompressible fluid in a horizontal porous medium with suction  

International Nuclear Information System (INIS)

A theoretical analysis of two-dimensional unsteady flow in a porous medium bounded by a horizontal wall is presented as a perturbation on a basic flow. It is assumed that the perturbation is occasioned by a sudden suction at the wall. Even for a highly permeable medium the characteristic Reynolds number in porous media flow is usually small and asymptotic solutions are developed by the Laplace transform technique. It is observed that the perturbed shear stress at the wall decays exponentially with time. (author). 5 refs.

2000-03-01

142

Thin Wall Iron Castings  

Energy Technology Data Exchange (ETDEWEB)

Results of an investigation made to develop methods of making iron castings having wall thicknesses as small as 2.5 mm in green sand molds are presented. It was found that thin wall ductile and compacted graphite iron castings can be made and have properties consistent with heavier castings. Green sand molding variables that affect casting dimensions were also identified.

2001-10-31

143

Survey of naturally radioactive level of some new type wall materials  

International Nuclear Information System (INIS)

Naturally occurring radioactive materials (NORM) in seven new type wall materials were surveyed. The radioactivity was determined with HPGe-#gamma# spectrometer. The red mud has the highest radioactivity concentration, followed by slag building blocks, fly-ash building blocks (bricks), gangue bricks and light weight board materials, gypsum blocks. Fly-ash and slag contain higher NORM, which contributes the major part of the radioactivity in new wall materials. (authors)

2006-09-01

144

Polymer depletion-induced slip near an interface  

Energy Technology Data Exchange (ETDEWEB)

A quantitative description is proposed for the depletion-induced slip thickness and velocity profile of a polymer solution near the wall-fluid interface in simple shear flow. The inhomogeneous polymer density profile at a flat wall is inserted into the equations of motion for the flow of a polymer solution near the flat wall. The theory is in quantitative agreement with simulation results. (letter to the editor)

2005-01-19

145

Modelling of the wall jet in a direct injection diesel engine  

Energy Technology Data Exchange (ETDEWEB)

As a part of a phenomenological model, a method for simulating the wall/jet interaction in a direct injection diesel engine is proposed. The method is based on the application of the momentum conservation equation in the different directions in which the wall jet is spread, and takes into account both the interaction with the combustion chamber geometry and with swirl. It takes as initial conditions the results of calculating the free jet, which is divided into packages. The predictions provide good agreement with those by other researchers. (author).

1992-01-01

146

A device for assemblying a support string for an offshore drilling rig  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the invention is to simplify assembly and to reduce labor intensity. This is achieved by the fact that the assembly shaft is positioned in a hawser, while its wall which is turned towards the body of the installation is combined with the hawser wall, where a U shaped opening is made in the wall of the assembly shaft, along the edges of which there is a hermetically sealing device, while the bottom of the body of the offshore drilling rig is equipped with a rigid insert attached with the capability of adjoining it with the hermetically sealing device.

1983-01-01

147

Real time neutron radiography using a Lixi neutron imaging device  

Energy Technology Data Exchange (ETDEWEB)

A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...

1986-01-15

148

Real time neutron radiography using a Lixi neutron imaging device  

International Nuclear Information System (INIS)

A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...

1986-01-01

149

Advances in Modeling of Scanning Charged-Particle-Microscopy Images  

CERN Document Server

Modeling artificial scanning electron microscope (SEM) and scanning ion microscope images has recently become important. This is because of the need to provide repeatable images with a priori determined parameters. Modeled artificial images are highly useful in the evaluation of new imaging and metrological techniques, like image-sharpness calculation, or drift-corrected image composition (DCIC). Originally, the NIST-developed artificial image generator was designed only to produce the SEM images of gold-on-carbon resolution sample for image-sharpness evaluation. Since then, the new improved version of the software was written in C++ programming language and is in the Public Domain. The current version of the software can generate arbitrary samples, any drift function, and many other features. This ...

2010-01-01

150

Magnetic resonance imaging in childhood epilepsy  

International Nuclear Information System (INIS)

The suitability of MR imaging versus computerized tomography in observation of brain development disorders in children are compared. 13 refs.

151

Esters useful as brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

Certain radioiodine containing esters useful as brain imaging agents are disclosed. The formula of these compounds are presented.

1981-08-18

152

Esters useful as brain imaging agents  

International Nuclear Information System (INIS)

Certain radioiodine containing esters useful as brain imaging agents are disclosed. The formula of these compounds are presented.

153

Amides useful as brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula

1981-07-21

154

Amides useful as brain imaging agents  

International Nuclear Information System (INIS)

Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula.

155

Image-enhancement applications at the Lawrence Livermore National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

A diverse set of digital image-processing applications exists at the Lawrence Livermore National Laboratory. While many of these include some sort of image analysis or restoration, virtually all of them require image-enhancement procedures. In this paper we describe the principal image-processing facility at the Laboratory, followed by a discussion of several of the major image-processing application areas.

1982-06-01

156

Void fraction measurements using neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography is being evaluated for studying the dynamic behavior of two-phase flow and for measuring void fraction in vertical and inclined water ducts. This technique provides a unique means of visualizing the behavior of fluid flow inside thick metal enclosures. An air-water flow system was constructed to simulate vapor conditions encountered in a fluid flow duct. Air was injected into the bottom of the duct at flow rates up to 0.47 {ell}/s (1 ft{sup 3}/min). The water flow rate was varied between 0 and 3.78 {ell}/min (0 to 1 gal/min). The experiments were performed at the Pennsylvania State University nuclear reactor facility using a real-time neutron radiography camera. With a thermal neutron flux on the order of 10{sup 6} n/cm{sup 2}{center_dot}s{sup {minus}1} directed through the thin duct dimension, the dynamic behavior of the air bubbles was clearly visible through 5-cm (2-in.)-thick aluminum support plates placed on both sides of the duct ...

1995-09-01

157

Void fraction measurements using neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography is being evaluated for studying the dynamic behavior of two phase flow and for measuring void fraction in vertical and inclined water ducts. This technique provides a unique means of visualizing the behavior of fluid flow inside thick metal enclosures. To simulate vapor conditions encountered in a fluid flow duct, an air-water flow system was constructed. Air was injected into the bottom of the duct at flow rates up to 0.47 I/s (1 cfm). The water flow rate was varied between 0--3.78 I/m (0--1 gpm). The experiments were performed at the Pennsylvania State University nuclear reactor facility using a real-time neutron radiography camera. With a thermal neutron flux on the order of 10{sup 6}n/cm{sup 2}/s directed through the thin duct dimension, the dynamic behavior of the air bubbles was clearly visible through 5 cm (2 in.) thick aluminum support plates placed on both sides of the duct wall. Image analysis techniques ...

1992-12-31

158

Void fraction measurements using neutron radiography  

International Nuclear Information System (INIS)

Real-time neutron radiography is being evaluated for studying the dynamic behavior of two-phase flow and for measuring void fraction in vertical and inclined water ducts. This technique provides a unique means of visualizing the behavior of fluid flow inside thick metal enclosures. An air-water flow system was constructed to simulate vapor conditions encountered in a fluid flow duct. Air was injected into the bottom of the duct at flow rates up to 0.47 ell/s (1 ft"3/min). The water flow rate was varied between 0 and 3.78 ell/min (0 to 1 gal/min). The experiments were performed at the Pennsylvania State University nuclear reactor facility using a real-time neutron radiography camera. With a thermal neutron flux on the order of 10"6 n/cm"2#centre dot#s"-"1 directed through the thin duct dimension, the dynamic behavior of the air bubbles was clearly visible through 5-cm (2-in.)-thick aluminum support plates placed on both sides of the duct wall. ...

1995-01-01

159

Focused Ion Beam Recovery of Hypervelocity Impact Residue in Experimental Craters on Metallic Foils.  

Energy Technology Data Exchange (ETDEWEB)

The Stardust sample return capsule will return to Earth in January 2006 with primitive debris collected from Comet 81P/Wild-2 during the fly-by encounter in 2004. In addition to the cometary particles embedded in low-density silica aerogel, there will be microcraters preserved in the Al foils (1100 series; 100 {micro}m thick) that are wrapped around the sample tray assembly. Soda lime spheres ({approx}49 {micro}m in diameter) have been accelerated with a Light Gas Gun into flight-grade Al foils at 6.35 km s{sup -1} to simulate the capture of cometary debris. The experimental craters have been analyzed using scanning electron microscopy (SEM) and x-ray energy dispersive spectroscopy (EDX) to locate and characterize remnants of the projectile material remaining within the craters. In addition, ion beam induced secondary electron imaging has proven particularly useful in identifying areas within the craters that contain residue material. Finally, high-precision ...

2005-11-04

160

CT findings of intrahepatic cholangiocarcinoma associated with hepatolithiasis  

International Nuclear Information System (INIS)

To assess the CT findings of intrahepatic cholangiocarcinoma associated with hepatolithiasis. The CT features of 26 patients with cholangiocarcinoma and hepatolithiasis were reviewed and compared with those of 23 patients with intrahepatic stones alone, acting as control subjects. CT findings were analyzed for tumor appearance and adjacency to hepatolithiasis. We studied clinical findings, noting the presence or absence of wall thickening or soft tissue attenuation within the bile duct, the luminal diameter of dilated bile duct, and the presence of periductal enhancement, and compared these with the findings for control groups. CT images of the tumor revealed a hepatic low-attenuating mass with peripheral rim enhancement(n = 14,54 %), or periductal thickening, or low-attenuating lesions in segmental dilatation of intrahepataic bile ducts(n = 12, 46 %). Most hepatic tumors were seen in areas adjacent to hepatolithiasis, or in a bile duct. ...

1999-09-01

161

Anatomic and radiologic correlations in spontaneous hematomas of the rectus abdomninis muscles; Correlazioni anatomo-radiologiche negli ematomi spontanei dei muscoli retti dell'addome  

Energy Technology Data Exchange (ETDEWEB)

Rectus sheath hematomas are a frequent but sometimes misdiagnosed disease in patients under anticoagulative drugs, hemodialysis, or simply in the elderly. The most frequent localization is in the lower part of the abdomen: the explanation lies in the anatomy of the abdominal wall, especially in the arcuate line of the rectus sheath. Aim of this work is to explain the reason of the almost constant location correlating the anatomy with the CT features. The rectus abdominis muscle lies between the aponeuroses of the transverse and oblique muscles which form the so called rectus sheath. This arrangement is found from the costal arch to a level approximately between the umbilicus and the pubic symphisis, where the rear layer of the rectus sheath ends with a curved edge, called the arcuate or semicircular line of Douglas. Beneath this line the aponeuroses of the three muscles pass in front of the rectus which is separated from the peritoneum only by the fascia ...

2000-06-01

162

The influence of wall deposits on heat transfer in combustion engines. Einfluss von Wandablagerungen auf den Waermeuebergang im Verbrennungsmotor  

Energy Technology Data Exchange (ETDEWEB)

The experimental survey about the heat transfer between the working fluid and the combustion chamber wall with a direct injection diesel engine has shown the production of a soot layer with increasing loads on the combustion chamber wall. Because the combustion process of methanol occurs without the formation of wall deposits, the same engine spark ignitioned with methanol at the same conditions has shown a higher heat transfer coefficient. Because the heat losses do not only depend on the heat transfer coefficient but also on the driving temperature difference between the working fluid and the combustion chamber wall, the methanol engine with corresponding process management showed lower heat losses than the diesel engine at nearly the same load. (orig./HW)

1994-04-01

163

Effect of convective wall currents on the air quality of source ventilation. Einfluss konvektiver Wandstroemungen auf die Luftqualitaet bei Quellueftung  

Energy Technology Data Exchange (ETDEWEB)

With the combination of source ventilation and ceiling cooling for air-conditioning of working and recreation rooms, a ventilation system is available which fulfills the highest demands regarding thermal comfort. In order to utilize the advantages of this ventilation system with regard to air quality and thermal comfort to an optimum, the influence of the radiation exchange between cooling ceiling and walls on the flow in the room is investigated experimentally. Energy transfer from the walls to the cooled ceiling may result in an insufficient temperature of the walls compared to ambient air and in an upward flow on the wall surfaces (downward flow of) driven by gravity, which influences the flow pattern in the case of source ventilation. (orig.)

1993-07-01

164

Dispersoid separation method and apparatus  

Energy Technology Data Exchange (ETDEWEB)

Improved separation of heavier material from a dispersoid of gas and heavier material entrained therein is taught by the method of this invention which advantageously uses apparatus embodied in an inertial separator having rotary partition means comprising wall members dividing a housing into a plurality of axially-extending through passages arranged in parallel. Simultaneously with the helical transit of a moving stream of the dispersoid through the parallel arrangement of axially-extending through passages at a constant angular velocity, the heavier material is driven radially to the collecting surfaces of the rotational wall members where it is collected while the wall members are rotating at the same angular velocity as the moving stream. The plurality of wall members not only provides an increased area of collecting surfaces but the positioning of each of the wall members ...

1980-01-01

165

A comparative assessment of slope stability of New Orleans I-wall with partial gap between the wall and layered cohesive backfill  

British Library Electronic Table of Contents (United Kingdom)

Following Hurricane Katrina, the study of cantilevered sheet pile I-wall with gap or partial gap has become one of the central elements of the ongoing investigation pertaining to the re-building of hurricane protection systems in New Orleans, LA. Historically, the US Army Corps of Engineers (USACE) had mostly relied upon the Method of Planes (MOP) analysis procedure for slope stability analysis of I-wall systems. However MOP is a simplified procedure which does not satisfy total equilibrium. Nevertheless, MOP is still considered by USACE as a popular analysis tool because of its simplicity and ease of use in slope stability analysis. This paper demonstrates the applicability and suitability of MOP as a viable analysis tool for the analysis of New Orleans I-wall founded on layered cohesive ...

2011-01-01

166

Unsteady state heat transfer in the vertical walls of a building  

Energy Technology Data Exchange (ETDEWEB)

The unsteady state heat transfer behaviour of a vertical wall subject to the effects of uniform radiation is investigated and the dimensional analysis of combined heat transfers by conduction, convection and radiation is presented. The convective heat transfer coefficients used in the numerical model are determined experimentally by means of an assembly resembling the conditions encountered in the dwelling (variable temperatures and heat flows in time and space, wall associated with a floor, radiative flux outside the wall). In routine conditions (homogeneous wall dimensions, temperature differentials less than 40/sup 0/C), it is shown that the problem depends in practice on three parameters (instead of five) and that nomographs can give the energy accumulated in the wall as a function of its geometric and thermal charactersitics and the external conditions (type and thickness of ...

1982-12-01

167

CFD Application to the Regulatory Assessment of FAC-Caused CANDU Feeder Pipe Wall Thinning Issue  

Energy Technology Data Exchange (ETDEWEB)

From the results of the In-Service Inspection (ISI) measuring the wall thickness of outlet (hot-leg side) feeder pipes performed at two Canadian nuclear power plants, Point Lepreau and Gentilly-2 in 1995 and 1996, respectively, the wall thinning degradation of feeder pipes at the bend part was found to be much more severe than expected. It has been well known that such wall thinning of feeder pipes is caused by the flow accelerated corrosion (FAC) which is one of the mechanical-chemical degradation mechanisms affecting the integrity of piping systems. For the Wolsung unit 1, the wall thickness measurements have been performed during every overhaul period since 1996. The wall thinning rates at the bends of outlet feeder pipes were assessed to exceed the design value. However, for the Wolsung units 2, 3 and 4, the wall thinning rates of all the outlet feeder pipes ...

2007-07-01

168

CFD Application to the Regulatory Assessment of FAC-Caused CANDU Feeder Pipe Wall Thinning Issue  

International Nuclear Information System (INIS)

From the results of the In-Service Inspection (ISI) measuring the wall thickness of outlet (hot-leg side) feeder pipes performed at two Canadian nuclear power plants, Point Lepreau and Gentilly-2 in 1995 and 1996, respectively, the wall thinning degradation of feeder pipes at the bend part was found to be much more severe than expected. It has been well known that such wall thinning of feeder pipes is caused by the flow accelerated corrosion (FAC) which is one of the mechanical-chemical degradation mechanisms affecting the integrity of piping systems. For the Wolsung unit 1, the wall thickness measurements have been performed during every overhaul period since 1996. The wall thinning rates at the bends of outlet feeder pipes were assessed to exceed the design value. However, for the Wolsung units 2, 3 and 4, the wall thinning rates of all the outlet feeder pipes ...

2007-05-10

169

An Effective Method of Image Retrieval using Image Mining Techniques  

CERN Document Server

The present research scholars are having keen interest in doing their research activities in the area of Data mining all over the world. Especially, [13]Mining Image data is the one of the essential features in this present scenario since image data plays vital role in every aspect of the system such as business for marketing, hospital for surgery, engineering for construction, Web for publication and so on. The other area in the Image mining system is the Content-Based Image Retrieval (CBIR) which performs retrieval based on the similarity defined in terms of extracted features with more objectiveness. The drawback in CBIR is the features of the query image alone are considered. Hence, a new technique called Image retrieval based on optimum clusters is proposed for improving user interaction with image retrieval systems by fully exploiting ...

2010-01-01

170

MRI-based N-staging in esophageal cancer; N-Staging des Oesophaguskarzinoms mittels MRT unter Verwendung von artefaktreduzierenden LOTA-Sequenzen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: For planning the therapeutic strategies and estimating the prognosis in esophageal cancer, N-staging is very important. To date, MRI still is of minor importance as imaging modality of the mediastinum despite promising developments in the past, like ECG-gating or 'averaging' sequences, e.g. LOTA (Long-term averaging), which facilitate mediastinal and thoracic MR-imaging. In a prospective approach, the value of MRI based N-staging was examined with respect to LOTA-sequences. Material and Methods: Within from weeks prior to esophagectomy, standardized MRI of the esophagus was performed in 15 patients (10 squamous-cell-carcinomas and 5 adenocarcinomas) using a 1.5 T whole body scanner. Imaging quality was classified based on depiction of aortic wall or tracheal wall layers. Criteria for malignant infiltration were a diameter of more than 15 mm or a round ...

2002-10-01

171

High-resolution beta imaging; L'imagerie beta haute resolution  

Energy Technology Data Exchange (ETDEWEB)

For many years, {beta} radioactivity has been used to label molecules and follow them in various biological processes. {beta} imaging is obtained by autoradiography. Classically made on films or on photographic emulsions, autoradiography is now supplanted by radio-imagers which are very performing. The phosphor-imager, {beta}-imager and {mu}-imager are the systems mainly used today and their operating principles and properties are compared. The great advantages of these imagers are: their rapidity to obtain results and their reliability for absolute quantification. All emitters ({beta}{sup -}, {beta}{sup -} -{gamma} and {beta}{sup +}) are detectable as well as the gamma emitters of nuclear medicine, by means of their low energy electrons ejected during y emission. Phosphor-imager is well suited to energetic tracers and large series of ...

2007-04-15

172

CR portal imaging; A linac graphy using storage phosphor imaging systems  

Energy Technology Data Exchange (ETDEWEB)

In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...

1992-07-01

173

Radioisotope imaging of brain tumors in two rhesus monkeys. Final report  

Energy Technology Data Exchange (ETDEWEB)

Two geriatic male rhesus monkeys were used for the radioisotope imaging in this research. Discussion of the radionuclide, materials, and method used to accomplish the neurologic examination and the results obtained, both during the procedure and confirmation of the results by necropsies were accompanied by color photos of scan images. Results were that the nuclear images provided accurate images of intracranial neoplasia.

1988-04-01

174

Impact of computers in radiography: the advent of digital radiography, part-2  

International Nuclear Information System (INIS)

Computed radiography (CR) systems use a photostimulable phosphor plate enclosed in a cassette. In CR, image acquisition is a two-stage process wherein image capture and image read out are done separately. Direct digital radiography (DR) systems, on the other hand, use detectors that have a combined image capture and image read out capability. DR systems are also called as DDR or ddR systems by some vendors. This article focuses on DR systems

2008-08-01

175

Fracture imaging with converted elastic waves  

Energy Technology Data Exchange (ETDEWEB)

This paper examines the seismic signatures of discrete, finite-length fractures, and outlines an approach for elastic, prestack reverse-time imaging of discrete fractures. The results of this study highlight the importance of incorporating fracture-generated P-S converted waves into the imaging method, and presents an alternate imaging condition that can be used in elastic reverse-time imaging when a direct wave is recorded (e.g., for crosswell and VSP acquisition geometries).

2001-05-29

176

Turbulent heat transfer augmentation using microscale disturbances inside the viscous sublayer  

Energy Technology Data Exchange (ETDEWEB)

The authors report here on an experimental study of heat transfer augmentation in turbulent flow. Enhancement strategies employed in this investigation are based on the near-wall mixing processes induced in the sublayer through appropriate wall and near-wall streamwise-periodic disturbances. Experiments are performed in a low-turbulence wind-tunnel with a high-aspect-ratio rectangular channel having either (a) two-dimensional periodic microgrooves on the wall, or (b) two-dimensional microcylinders placed in the immediate vicinity of the wall. It is found that microdisturbances placed inside the sublayer induce favorable heat-transport augmentation with respect to the smooth-wall case, in the near-analogous momentum and heat transfer behavior are preserved; a roughly commensurate increase in heat and momentum transport is termed favorable in that it leads to a ...

1992-05-01

177

The EU HT test programme of ITER primary wall small scale mock ups  

International Nuclear Information System (INIS)

This paper summarises the main results obtained so far in the frame of the EU Home Team test programme of ITER primary wall small scale mock ups. It describes briefly the fabrication method of the mock ups, the test conditions and the main results obtained with high heat flux and thermal fatigue tests of Cu alloy/stainless steel and beryllium/Cu alloy/stainless steel mock ups. The results obtained so far show good thermal fatigue performance and operation margin of the ITER primary first wall concept. (author)

1998-09-07

178

Structural integrity of whipping pipes following a postulated circumferential break - a contribution to determining strain levels acceptable under faulted conditions  

Energy Technology Data Exchange (ETDEWEB)

It is postulated that a break of a thin-walled pipe does not cause a subsequent break in the pipe in the vicinity of a plastic hinge even when the wall is weakened by a 60 circumferential crack of a depth of 30% of the wall thickness on the tension side. This pipe behavior is the result of plastic buckling in the compression side and applies to pipes of diameter-to-thickness ratio larger than 20. For this type of pipe, the axial strains decrease with increasing diameter-to-thickness ratio in the tension side. As the pipe is only loaded in one direction, there is no cyclic behavior that can trigger a subsequent break. (orig.)

1993-10-01

179

Main achievements of the EU HT test programme of ITER primary wall small scale mock ups  

International Nuclear Information System (INIS)

This paper presents the main achievements of the European Home Team (EU HT) test programme of ITER primary wall small scale mock ups. It describes briefly the fabrication method of the mock ups, the test conditions and the main results obtained with high heat flux and thermal fatigue tests of Cu alloy/stainless steel and beryllium/Cu alloy/stainless steel mock ups. The results obtained so far show very good thermal fatigue performance and operation margin of the ITER primary first wall concept.

2000-11-01

180

Magnetization reversal phenomena and domain wall behaviours in nanostructured magnetic systems  

International Nuclear Information System (INIS)

Several recent experiments on micro- (or nano-) structured samples of ferromagnetic materials are introduced. Magnetization reversal phenomena are investigated on submicron wire samples of trilayer structure using the giant magnetoresistance effect. Domain wall movements are sensitively monitored by resistivity measurements and the velocity of propagation is determined. The contribution of domain wall to the resistivity is argued from the results on artificially designed samples of a spring-magnet system. In circular dots of permalloy, the existence of vortex magnetization is confirmed and the reversal of the vortex core magnetization is studied from magnetic force microscopy measurements. (author)

2001-09-23

181

Creation of an antiferromagnetic exchange spring  

Science.gov (United States)

We present evidence for the creation of an exchange spring in an antiferromagnet due to exchange coupling to a ferromagnet. X-ray magnetic linear dichroism spectroscopy on single crystal Co/NiO(001) shows that a partial domain wall is wound up at the surface of the antiferromagnet when the adjacent ferromagnet is rotated by a magnetic field. We determine the interface exchange stiffness and the antiferromagnetic domain wall energy from the field dependence of the direction of the antiferromagnetic axis, the antiferromagnetic pendant to a ferromagnetic hysteresis loop. The existence of a planar antiferromagnetic domain wall, proven by our measurement, is a key assumption of most exchange bias models.

2004-04-06

182

Conjugate parallel-flowing free and forced convection boundary layers on vertical wall sides  

Energy Technology Data Exchange (ETDEWEB)

The paper describes an analytical study of two parallel-flowing boundary layers of free and forced convection modes on the facing sides of a vertical thin wall. The two layers are analyzed separately within the framework of boundary layer theory, and coupled by the matching conditions at wall. Numerical data are obtained for a wide range of a dimensionless conjugation parameter {zeta} relating the heat transfer effectiveness of two convection modes. Based on these data, an expression for calculating the conjugate mean Nusselt number as a function of {zeta}-parameter is found by means of a curve-fitting method. (orig.)

2003-02-01

183

Aspiration cover for the loading site of a belt conveyer  

Energy Technology Data Exchange (ETDEWEB)

An aspiration cover is proposed for the site of loading a belt conveyer including a housing arranged above the belt conveyer in whose cover there is an aspiration sleeve and a discharge chute from the upper wall and a guide having a cushioning plate on the lower end. It is distinguished by the fact that in order to improve the effectiveness of removing dust by decreasing the volume of aspirated air, the cover between the aspiration sleeve and the upper wall of the loading chute is convex in the inside of the housing and has a smooth connection to the upper wall of the discharge chute turned towards the cushioning plate.

1982-01-01

184

Real-time neutron coded aperture imaging: A technique for nondestructive three-dimensional imaging  

Energy Technology Data Exchange (ETDEWEB)

Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only a small fraction of ...

1992-01-01

185

The Possibility of Digital Imaging in the Diagnosis of Occlusal Caries  

UK PubMed Central (United Kingdom)

The aim of this study was to assess the possibility of digital image analysis of pit-and-fissure discoloration in order to diagnose caries. Digital images showing pit-and-fissure discoloration in 100...Full Text Available

2010-01-01

186

Selective imaging of adherent targeted ultrasound contrast agents  

UK PubMed Central (United Kingdom)

The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available

2007-04-21

187

Radionuclide imaging of the acutely painful scrotum  

International Nuclear Information System (INIS)

This paper discusses the clinical application and main objective of testicular imaging. The authors present cases that represent a spectrum of the abnormalities which might be detected by testicular imaging, with special attention given to testicular torsion and the acute diseases which may mimic it clinically. Accuracy of the test is noted.

188

Quantifying the accuracy of automated structure segmentation in 4D CT images using a deformable image registration algorithm  

UK PubMed Central (United Kingdom)

Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. One key component of 4D radiotherapy planning...Full Text Available

2008-04-01

189

Performance evaluation of an automatic anatomy segmentation algorithm on repeat or four-dimensional CT images using a deformable image registration method  

UK PubMed Central (United Kingdom)

PurposeAuto-propagation of anatomical region-of-interests (ROIs) from the planning CT to daily CT is an essential step in image-guided adaptive radiotherapy. The...Full Text Available

2008-09-01

190

Nonnegative Factorization of Diffusion Tensor Images and Its Applications  

UK PubMed Central (United Kingdom)

This paper proposes a novel method for computing linear basis images from tensor-valued image data. As a generalization of the nonnegative matrix factorization, the proposed method aims to approximate...Full Text Available

2011-01-01

191

Near Infrared-Fluorescent and Magnetic Resonance Imaging Molecular Probe with High T1 Relaxivity for In Vivo Multimodal Imaging  

UK PubMed Central (United Kingdom)

A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.

2010-06-07

192

MULTIMODALITY IMAGING: BEYOND PET/CT AND SPECT/CT  

UK PubMed Central (United Kingdom)

Multimodality imaging with PET/CT and SPECT/CT has become commonplace in clinical practice and in preclinical and basic medical research. Do other combinations of imaging modalities have a similar...Full Text Available

2009-09-01

193

Longitudinal assessment of lung cancer progression in the mouse using in vivo micro-CT imaging  

UK PubMed Central (United Kingdom)

Purpose: Small animal micro-CT imaging is being used increasingly in preclinical biomedical research to provide phenotypic descriptions of genomic models. Most of this imaging is coincident...Full Text Available

2010-09-01

194

Imaging of calcium transients in skeletal muscle fibers.  

UK PubMed Central (United Kingdom)

Epifluorescence images of Ca2+ transients elicited by electrical stimulation of single skeletal muscle fibers were studied with fast imaging techniques that take advantage of the large fluorescence...Full Text Available

1991-01-01

195

High speed optical coherence microscopy with autofocus adjustment and a miniaturized endoscopic imaging probe  

UK PubMed Central (United Kingdom)

Optical coherence microscopy (OCM) is a promising technique or high resolution cellular imaging in human tissues. An OCM system for high-speed en face cellular resolution imaging...Full Text Available

2010-03-01

196

Diagnostic radiology: An Anglo-American textbook of imaging  

Energy Technology Data Exchange (ETDEWEB)

This multiauthored text is aimed particularly toward the resident or registrar training in diagnostic radiology. This is a text book on the entire scope of diagnostic imaging. It includes techniques and imaging modalities of all the systems, head, face and neck. The book covers the entire gamut of diagnostic radiology.

1986-01-01

197

Diagnostic quality of low resolution images for tele-woundcare.  

UK PubMed Central (United Kingdom)

The use of digital wound images would allow remote consultation between patients, physicians, or other caregivers over the Internet. To evaluate the efficacy and validity of digital images for assessment...Full Text Available

1998-01-01

198

Comprehensive Quantification of Signal-to-Noise Ratio and g-Factor for Image-Based and k-Space-Based Parallel Imaging Reconstructions  

UK PubMed Central (United Kingdom)

Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final...Full Text Available

2008-10-01

199

Comparative evaluation of similarity measures for the rigid registration of multi-modal head images  

Energy Technology Data Exchange (ETDEWEB)

Image registrations that are based on similarity measures simply adjust the parameters of an appropriate spatial transformation model until the similarity measure reaches an optimum. The numerous similarity measures that have been proposed in the past are differently sensitive to imaging modality, image content and differences in the image content, selection of the floating and target image, partial image overlap, etc. In this paper, we evaluate and compare 12 similarity measures for the rigid registration. To study the impact of different imaging modalities on the behavior of similarity measures, we have used 16 CT/MR and 6 PET/MR image pairs with known 'gold standard' registrations. The results for the PET/MR registration and for the registration of CT to both rectified and unrectified MR ...

2007-09-21

200

Compact Image Slicing Spectrometer (ISS) for hyperspectral fluorescence microscopy  

UK PubMed Central (United Kingdom)

An image slicing spectrometer (ISS) for microscopy applications is presented. Its principle is based on the redirecting of image zones by specially organized thin mirrors within a custom fabricated...Full Text Available

2009-07-20

201

CR portal imaging  

International Nuclear Information System (INIS)

In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...

1992-01-01

202

An Evaluation of a Computer Imaging Program to Prepare Women for Chemotherapy-related Alopecia  

UK PubMed Central (United Kingdom)

ObjectiveThis study was conducted to evaluate a computer-imaging program called HAAIR (Help with Adjustment to Alopecia by Image Recovery) that was developed to provide...Full Text Available

2010-07-01

203

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT  

UK PubMed Central (United Kingdom)

Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available

2010-01-01

204

WALL PRESSURE FLUCTUATIONS UNDER TURBULENT ...  

Science.gov (United States)

... necessary to allow for the effata nr the finits size of the oressure tranaducer on both the root mean square and power spectral density measurements ...

1963-04-01

205

Strain Rate Effects on Ultimate Strain of Copper  

Science.gov (United States)

... Figure 3a. PETN Filled Tube Specimen Detonated by Exploding Bridgewire Specimen POLYETIILLENE END-CAP "1- 901am WALL IHICKNESS ...

1979-05-01

206

Semi Annual Progress Report on BLADE END WALL FLOWS IN COMPRESSORS ...  

Science.gov (United States)

Eckert, B., "Axial Kompressoren und Radial Kompressoren," Springer. Verlag, Berlin, 1953. 3. Lebot, Y., et al., "Theoretical and Experimental Determination ...

207

SPACE STATION INTEGRATED WALL DESIGN AND PENETRATION  

Science.gov (United States)

screens of fine wire was placed between the gun barrel and the panel to determine whether the gun performance was repeatable. The transducers were placed ...

208

Review of Polyarylacetylene Matrices for Thin-Walled ...  

Science.gov (United States)

... After strip- ping off the chloroform, the dibromo ethyl (EDBEB) compounds are separated from the m-BDBEB using a thin film evaporator. ...

1989-09-25

209

Pressure-induced structural transitions in multi-walled carbon nanotubes  

British Library Electronic Table of Contents (United Kingdom)

We demonstrate a novel cross-sectional deformation, called the radial corrugation, of multi-walled carbon nanotubes (MWNTs) under hydrostatic pressure. Theoretical analyses based on the continuum elastic approximation have revealed that MWNTs consisting of more than ten concentric walls undergo elastic deformations at critical pressure Formula Not Shown , above which the circular shape of the cross-section becomes radially corrugated. Various corrugation modes have been observed by tuning the innermost tube diameter and the number of constituent walls, which is a direct consequence of the core-shell structure of MWNTs. Cross-sectional views of MWNT under high hydrostatic pressure: elliptic deformation with the mode index n = 2 (left), and radial corrugations with n = 5 (center), and n = 6 ...

2009-01-01

210

Optimization of Hydrogen Consumption in Hydrogen Masers  

Science.gov (United States)

... Hydro- gen gas is fed through a temperature- controlled Pd-Ag leak 161 into a cylindrical double-walled Pyrex bulb, 15 cm long and 1.9 cm in ...

1990-08-06

211

Neural Tissues from the Implanted Stem Cells  

International Science & Technology Center (ISTC)

Morphological, Electrophysiological and Behavioral Investigations of the Nervous Tissue Developed from the Embryonic Matrix Zone Cells of the Dorsolateral Walls of Lateral Ventricles, Implanted into the Lesioned Regions of the Adult Rat's Brain

212

Mechanical jacks meant to support the movable shielding wall (Proton Room side) of the SC  

CERN Document Server

This mechanical version was soon after changed into a hydraulic jack one (the reason being a number of serious constructional defects).

1955-01-01

213

Magnetohydrodynamic structure of a plasmoid in fast ... - NASA  

Science.gov (United States)

We set a symmetric boundary at x=200 and a conducting wall at z=150. The domain of 0200. 0150 is resolved by 60004500 grid cells. Harris sheet ...

214

Glassy Carbon, Alloys  

Science.gov (United States)

... 2.2.1 Polymerization of DVB Under Pressure DVB was polymerized at 300*C in thin-walled Pd-Ag capsules at pressures up to 60,000 psi. ...

1972-07-27

215

Fractional domain walls from on-site softening in dipolar bosons  

CERN Document Server

We study dipolar bosons in a 1D optical lattice and identify a region in parameter space---strong coupling but relatively weak on-site repulsion---hosting a series of stable CDW states whose low-energy excitations, built from "fractional domain walls", are remarkably similar to those of non-abelian fractional quantum Hall states. Here, a conventional domain wall between translated CDW's may split by inserting strings of degenerate, but inequivalent, CDW states. Outside these insulating regions, we find numerous supersolids as well as a superfluid regime. The mentioned phases should be accessible experimentally, and in particular, the fractional domain walls can be created in the ground state using single-site addressing, i.e. by locally changing the chemical potential.

2011-01-01

216

FINAL REPORT CONTINUOUS SCANNING METEOROLOGICAL CAMERA SYSTEM FOR ...  

Science.gov (United States)

was deemed adequate and a cooling system designed utilizing the Melcor CP2-15- 10B thermoelectric module. Wall temperature achieved with this system was - 36 ...

217

Elastodynamics of vehicles and crash simulation  

Energy Technology Data Exchange (ETDEWEB)

Accidents of free-rolling cars against walls with friction are special cases of the general problem of the dynamic behavior (elastic or plastic) of car motion. Using particle modeling of the car body it is shown that large rotations, contact friction and plastic deformations can be computed. Because of the limitations of FEM it is necessary to model the car as a system of mass points connected by central force systems which are non-linear. The wall is formulated as a rigid body producing constraints for the contacting particles, while the contact force is given by the defined force system. Every contacting particle produces a plastic impact on the wall. The friction force is proportional to the contact force and lies in the direction of the sliding velocity on the wall. Time integration is carried out using a second order Gear method. ((orig.))

1994-09-30

218

DESIGN OF A CONVECTIVE COOLING SYSTEM FOR A MACH 6 - NASA ...  

Science.gov (United States)

Figure 23 presented detailed layout of the cooling system designed for the Mach 6 hypersonic- transport. The distribution system consisted of thin-wall ...

219

Approximate solutions to the Stefan problem with internal heat generation  

Energy Technology Data Exchange (ETDEWEB)

Using a quasi-static approach valid for Stefan numbers less than one, we derive approximate equations governing the movement of a phase change front for materials which generate internal heat. These models are applied for both constant surface temperature and constant surface heat flux boundary conditions, in cylindrical, spherical, plane wall and semi-infinite geometries. Exact solutions with the constant surface temperature condition are obtained for the steady-state solidification thickness using the cylinder, sphere, and plane wall geometries which show that the thickness depends on the inverse square root of the internal heat generation. Under constant surface heat flux conditions, closed form equations can be obtained for the three geometries. In the case of the semi-infinite wall, we show that for constant temperature and constant heat flux out of the wall conditions, the solidification layer ...

2008-05-15

220

Analysis of Rough Wall Turbulent Heating with Application to ...  

Science.gov (United States)

... roughness. Since T u'v' and q v'"F the heat transfer augmentation is the square root of the skin friction augmentation: - 1/2 (( St - ,Cf 0 ...

1979-01-01

221

9902631 - Lysozyme - NASA  

Science.gov (United States)

Protein isolated from hen egg-white and functions as a bacteriostatic enzyme by degrading bacterial cell walls. First enzyme ever characterized by protein ...

222

Post-mortem fetal MRI: What do we learn from it?  

International Nuclear Information System (INIS)

Post-mortem magnetic resonance (MR) imaging is of increasing interest not only as an alternative to autopsy but as a research tool to aid the interpretation and diagnosis of in utero MR images. The information from the post-mortem MR has allowed the development of imaging sequences applicable to in utero imaging and neonatal imaging. It has established brain development during gestation and has provided data on this to which in utero MR can be compared. The detail available from the post-mortem images is such that brain development can be studied in a non-invasive manner, a permanent record on the normal and abnormal areas is available and a greater understanding of developmental abnormalities is possible.

2006-02-01

223

MR imaging in neuroborreliosis of the cervical spinal cord  

Energy Technology Data Exchange (ETDEWEB)

The central nervous system is involved in 10-20% of cases in Lyme disease. The neurological symptoms, time course of the disease and imaging findings are multifaceted. We report two patients with cervical radiculitis. Magnetic resonance imaging revealed strong enhancement of the cervical nerve roots on contrast-enhanced T1-weighted images. These imaging patterns of borrelia-associated radiculitis have not been reported before. Knowledge of these imaging features may help to diagnose neuroborreliosis, which presents with non-specific symptoms. (orig.)

2004-11-01

224

Future of X-ray phase imaging in medical imaging technology  

International Nuclear Information System (INIS)

Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)

2007-04-01

225

MRT of the abdomen in combination with enteroclysis in Crohn disease with oral and intravenous Gd-DTPA; MRT des Abdomens in Kombination mit der Enteroklyse bei Morbus Crohn unter Verwendung von oralem und intravenoesem Gd-DTPA  

Energy Technology Data Exchange (ETDEWEB)

60 patients between 17 and 72 years of age were investigated. First, an enteroclysis was performed in typical manner. The applicated methylcellulosis was blended with positive oral MR contrast media (Magnevist oral, Schering). After enteroclysis, MRI of the abdomen was performed using T1- and T2-weighted breathhold sequences (Flash 2D pre- and postcontrast and TSE) in axial and coronal planes. The length of the affected bowel and the stenosis seen with enteroclysis correlated well with the visible thickening of the small bowel wall and the stenosis seen in MRI. Using MRI, additional findings could be obtained in 28 patients, such as fistulas, abscesses or a hydronephrosis, or a better assessment of the stenosis was possible with MRI, because of the avoidance of overshadowing of the affected bowel loop with MRI. A brilliant MR-tomographic imaging of the small bowel is possible under the condition, that the small bowel contrast is optimal. The ...

1998-01-01

226

In-vivo blood velocity and velocity gradient profiles downstream of stented and stentless aortic heart valves  

DEFF Research Database (Denmark)

BACKGROUND AND AIM OF THE STUDY: Abnormal flow conditions across aortic bioprosthetic valves may result in degenerative processes. Thus, it is important to implant biological valve prostheses with velocity profiles similar to those of native valves. The study aim was to compare blood velocity and velocity gradient profiles downstream of stented and stentless aortic valves implanted in pigs, and in native porcine valves. METHODS: Stented valve prostheses (Mitroflow, n = 7) or stentless valve prostheses (Solo, n = 5 or Toronto SPV, n = 7) were implanted into pigs; the native valve was retained in eight animals. After weaning the animals from cardiopulmonary bypass, cardiac magnetic resonance imaging was performed to determine the blood velocities and velocity gradient profiles. RESULTS: The native valves had a significantly lower peakvelocity (92 +/- 26 cm/s) than the artificial valves (Solo: 247 +/- 107 cm/s; Toronto: 252 +/- 41 cm/s; Mitroflow: 229 +/- 18 cm/s). ...

2010-01-01

227

Cellular Sources of Transforming Growth Factor-? Isoforms in Early and Chronic Radiation Enteropathy  

Science.gov (United States)

The three mammalian transforming growth factor (TGF)-? isoforms (TGF-?1, TGF-?2, and TGF-?3) differ in their putative roles in radiation-induced fibrosis in intestine and other organs. Furthermore, tissue specificity of TGF-? action may result from temporal or spatial changes in production and/or activation. The present study examined shifts in the cell types expressing TGF-? mRNA relative to TGF-? immunoreactivity and histopathological injury during radiation enteropathy development. A 4-cm loop of rat small intestine was locally exposed to 0, 12, or 21-Gy single doses of x-irradiation. Sham-irradiated and irradiated intestine were procured 2 and 26 weeks after irradiation. Cells expressing the TGF-?1, TGF-?2, or TGF-?3 transcripts were identified by in situ hybridization with digoxigenin-labeled riboprobes. Intestinal wall TGF-? immunoreactivity was measured using computerized image analysis, and structural radiation injury was assessed by ...

1998-11-01

228

Typhoon Aere : Image of the Day - NASA Earth Observatory  

Science.gov (United States)

Aug 25, 2004 ... The Tropical Rainfall Measuring Mission or TRMM satellite provided this image of Typhoon Aere over the western Philippine Sea as it was ...

229

The importance of radiation quality for optimisation in radiology  

UK PubMed Central (United Kingdom)

Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available

230

The Use of Medical Images in Planning and Delivery of Radiation Therapy  

UK PubMed Central (United Kingdom)

Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available

1997-09-01

231

Portal localization images using computed radiography for high-energy electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy electron beam therapy. (author)

2002-09-01

232

Method for the reduction of image content redundancy in large image databases  

Energy Technology Data Exchange (ETDEWEB)

A method of increasing information content for content-based image retrieval (CBIR) systems includes the steps of providing a CBIR database, the database having an index for a plurality of stored digital images using a plurality of feature vectors, the feature vectors corresponding to distinct descriptive characteristics of the images. A visual similarity parameter value is calculated based on a degree of visual similarity between features vectors of an incoming image being considered for entry into the database and feature vectors associated with a most similar of the stored images. Based on said visual similarity parameter value it is determined whether to store or how long to store the feature vectors associated with the incoming image in the database.

2010-03-02

233

JHK and 3.3um PAH Imaging of the Starburst Ring in the Type I Seyfert Galaxy NGC 7469  

Science.gov (United States)

Imaging of NGC 7469 in the J, H, & K bands shows that the starburst 'ring' is a tight inner

1993-01-01

234

Implementation of improved interactive image analysis at the Advanced Photon Source (APC) linac.  

Energy Technology Data Exchange (ETDEWEB)

An image-analysis system, based on commercially available data visualization software (IDL [1]), allows convenient interaction with image data while still providing calculated beam parameters at a rate of up to 2 Hz. Image data are transferred from the IOC to the workstation via EPICS [2] channel access. A custom EPICS record was created in order to overcome the channel access limit of 16k bytes per array. The user can conveniently calibrate optical transition radiation (OTR) and fluorescent screens, capture background images, acquire and average a series of images, and specify several other filtering and viewing options. The images can be saved in either IDL format or APS-standard format (SDDS [3]), allowing for rapid postprocessing of image data by numerous other software tools.

1998-09-11

235

Imaging subsurface using cross-correlation  

Energy Technology Data Exchange (ETDEWEB)

This paper presents two imaging methods by using cross correlation. The one method images the subsurface by cross-correlation of the observed data and partial derivative seismograms calculated for a guessed model. The other method images the interface by use of cross-correlation of the virtual sources and the back propagated wave fields calculated from the observed data. Experimental tests show that both methods image subsurface interfaces well even if the guessed model is different from the true one. These imaging methods are reverse time migration that we perform cross-correlation as an imaging condition and have an advantage, as compared to conventional waveform inversion method, that images subsurface structure without iterative perturbation of the assumed model. (author). 18 refs., 15 figs.

1997-12-31

236

Image Analysis and Computer Vision: 1996.  

Science.gov (United States)

... Title : Image Analysis and Computer Vision: 1996. ... bibliography,. Corporate Author : MARYLAND UNIV COLLEGE PARK COMPUTER VISION LAB. ...

1997-01-01

237

Histopathological Image Analysis: A Review  

UK PubMed Central (United Kingdom)

Over the past decade, dramatic increases in computational power and improvement in image analysis algorithms have allowed the development of powerful computer-assisted analytical approaches...Full Text Available

2009-01-01

238

X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography  

International Nuclear Information System (INIS)

Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a ...

2002-03-01

239

Phantom and animal imaging studies using PLS synchrotron X-rays  

CERN Document Server

Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and ...

2001-01-01

240

Combining anatomy and function: the path to true image fusion  

Energy Technology Data Exchange (ETDEWEB)

Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localization of abnormalities. The resulting correlation of the anatomical and functional images may clarify the nature of the abnormality and help diagnose or stage the underlying disease. Whereas successful image fusion software has been developed for the brain, only limited success has been achieved for image alignment in other parts of the body. The development and current status of alternative approaches are presented. Dual-modality imaging is described with devices where two modalities are combined and mounted ...

2001-10-01

241

Approximate fuzzy C-means (AFCM) cluster analysis of medical magnetic resonance image (MRI) data  

International Nuclear Information System (INIS)

The authors describe the application of an approximate fuzzy C-means (AFCM) clustering algorithm as a data dimension reduction approach to medical magnetic resonance images (MRI). Image data consisted of one T1-weighted, two T2-weighted, and one T2*-weighted (magnetic susceptibility) image for each cranial study and a matrix of 10 images generated from 10 combinations of TE and TR for each body lymphoma study. All images were obtained with a 1.5 Tesla imaging system (GE Signa). Analyses were performed on over 100 MR image sets with a variety of pathologies. The cluster analysis was operated in an unsupervised mode and computational overhead was minimized by utilizing a table look-up approach without adversely affecting accuracy. Image data were first segmented into 2 coarse clusters, each of which was then subdivided ...

242

The two-dimensional Stefan problem with slightly varying heat flux  

Science.gov (United States)

The authors solve the two-dimensional stefan problem of solidification in a half-space, where the heat flux at the wall is a slightly varying function of positioning along the wall, by means of a large Stefan number approximation (which turns out to be equivalent to a small time solution), and then by means of the Heat Balance Integral Method, which is valid for all time, and which agrees with the large Stefan number solution for small times. A representative solution is given for a particular form of the heat flux perturbation.

1995-09-01

243

TRANSMUTATIONS IN SiC IRRADIATED IN ARIES-IV FIRST WALL  

Science.gov (United States)

The change in concentrations of elements due to transmutations resulting from neutron irradiation in the first wall of the ARIES-IV conceptual fusion energy device were determined as a function of neutron dose. SiC burns out at a rate of about 0.5% per effective full power year. The largest impurity concentration is that of He, but several other elements burn in at rates of hundreds of appm/efpy.

2001-04-01

244

Steelbiz Shop  

Wastenet

... The composite ground floor is suitable for support to all types of wall construction and can be used equally well on strip footings or mini-pile foundations . The light steel edge beams provide the accurate template required for internal timber or light steel wall frames to minimise fitting time and eliminate rework. The floated slab surface will accept floor finishes directly and thermal insulation can be easily fitted beneath ...

245

Solar collectors with tubes partially filled with porous substrates  

Energy Technology Data Exchange (ETDEWEB)

In this work, the thermal performance of a conventional collector is improved by inserting porous substrates at the inner walls of the collector tubes. The porous substrates improve the convective heat transfer coefficient between the tube wall and the fluid. This improvement is investigated numerically and its effects on the efficiency and the useful gain of the collector are evaluated. It is found that inserting the porous substrate may raise the collector efficiency considerably, especially at high values of the overall heat loss coefficient.

1999-02-01

246

Polymeric wall sealant test for radon control in a uranium mine  

International Nuclear Information System (INIS)

The effectiveness of an acrylic latex wall sealant in limiting the escape of radon from rock in underground mines is the subject of this paper. Application of the latex as a two-coat system over a fillter coat of gunite produced a reduction of radon concentration from an initial level of 80 to 100 pCi/L to a final average of 25 to 30 pCi/L under similar conditions.

247

NAME=\\  

Wastenet

...direct-injection systems Atomisation from hole-type nozzles (gasoline and diesel) under cavitating flow conditions Spray-wall interaction in gasoline direct injection engines Spray-wall interaction in direct-injection diesel engines Evaporation of multi-component fuels Cavitation in diesel injectors Nozzle flow, air motion, spray development and combustion in marine diesel engines ...

248

Free convection heat and mass transfer to steady flow in a semi-infinite vertical porous medium  

Science.gov (United States)

Analytical solutions are derived for a flow in a semi-infinite vertical porous medium with heat and mass transfer. When the temperature and mass concentration are uniform a constant pressure is possible and sustains a fully developed flow. Thereafter there is a small perturbation on the wall temperature and concentration and the subsequent two-dimensional problem is tackled for a large Prandtl number, free convection parameters and small Reynolds number. The heat transfer rate at the wall is discussed quantitatively.

1988-02-01

249

Fouling Study of Silicon Oxide Pores Exposed to Tap Water  

Energy Technology Data Exchange (ETDEWEB)

We report on the fouling of Focused Ion Beam (FIB)-fabricated silicon oxide nanopores after exposure to tap water for two weeks. Pore clogging was monitored by Scanning Electron Microscopy (SEM) on both bare silicon oxide and chemically functionalized nanopores. While fouling occurred on hydrophilic silicon oxide pore walls, the hydrophobic nature of alkane chains prevented clogging on the chemically functionalized pore walls. These results have implications for nanopore sensing platform design.

2007-07-12

250

Fabrication of nanoscale Ti honeycombs by focused ion beam  

Energy Technology Data Exchange (ETDEWEB)

Ti honeycombs with the side of 800 and 400 nm were fabricated by focused ion beam (FIB), though the surfaces of the bottom and wall of the Ti honeycombs were rough, as compared with the surfaces of the bottom and wall of the Si honeycomb. It is demonstrated that the nanoscale Ti components can be fabricated in a short time by FIB.

2003-03-15

251

Fabrication and testing of small scale mock-ups of ITER shielding blanket  

International Nuclear Information System (INIS)

Small scale mock-ups of the primary first wall, the baffle first wall, the shield block and a partial model for the edge of the primary first wall module were designed and fabricated incorporating most of the key design features of the ITER shielding blanket. All mock-ups featured the DSCu heat sink, the built-in SS coolant tubes within the heat sink and the SS shield block. CFC tiles was used as the protection armor for the baffle first wall mock-up. The small scale shield block mock-up, integrated with the first wall, was designed to have a poloidal curvature specified in the ITER design. Fabrication routes of mock-ups were decided based on the single step solid HIP of DSCu/DSCu, DSCu/SS and SS/SS reflecting the results of previous joining techniques development and testing. For attaching the CFC tiles onto DSCu heat sink in the fabrication of the baffle first ...

1998-09-01

252

Doublet III limiter/armor update  

Energy Technology Data Exchange (ETDEWEB)

The Doublet III device is operating with an extensive system of plasma limiters and wall protective armor. Operations with up to 8MW of neutral beam power and 1.5MA plasma current are planned. Design and operational performance of the following systems are discussed: 1. Water-cooled graphite moveable limiter. 2. Water-cooled graphite fixed limiter and neutral beam wall armor. 3. Radiatively cooled Inconel divertor plates.

1983-12-01

253

Battery side terminal  

Energy Technology Data Exchange (ETDEWEB)

A side terminal battery is described comprising: a casing having a side wall made from a moldable material; and a plug formed of relatively deformable, electrically conductive, corrosion resistant material molded into the side wall to form a seal between the interior and exterior of the casing and including a battery terminal insert embedded therein so as to be exposed at the exterior of the casing and isolated, by the plug, from the interior of the casing.

1988-03-08

254

Simulation of electromechanical and thermomechanical loads on first wall mock-ups  

International Nuclear Information System (INIS)

During the operation of a tokamak, the first wall elements suffer very high heat fluxes. Heat is removed by internal cooling by means of water, helium or fluid metal. The resulting inhomogeneous temperature field cause internal stresses which, due to the pulsed operation are of cyclic nature. Additional mechanical stresses in the first wall may be caused by disruptions or vertical plasma movements. During theses events high currents are induced in the metallic part of the first wall which by their interaction with the magnetic field of the tokamak lead to mechanical forces. These electromechanical stresses may lie beyond the yield stress of the structural material. From the interaction of thermal and mechanical forces, a complex stress state is achieved which under certain circumstances may lead to premature failure and/or to progressive plastic deformations (ratcheting). In order to study the boundary conditions for the ...

255

Powder collection apparatus/method  

Energy Technology Data Exchange (ETDEWEB)

Device for separating and collecting ultrafine atomized powder from the gas stream of a gas atomizing apparatus comprises a housing having an interior wall oriented at an angle relative to horizontal so as to form a downwardly converging, conical expansion chamber, an inlet conduit communicated to the expansion chamber proximate an upper region thereof for receiving the gas stream, and an outlet proximate a lower region of the expansion chamber. The inlet conduit is oriented at a compound inclined angle (with respect to horizontal) selected to promote separation and collection of powder from the gas stream in the expansion chamber. The compound angle comprises a first entrance angle that is greater than the angle of repose of the powder on the housing interior wall such that any powder accumulation in the inlet conduit tends to flow down the wall toward the outlet. The second angle is selected generally equal to the angle ...

1994-01-11

256

Four loss-of-flow accidents in the SEAFP first wall/blanket cooling system  

Energy Technology Data Exchange (ETDEWEB)

This report presents the thermal-hydraulic analysis of four Loss-of-Flow Accidents (LOFAs) in the first wall/blanket cooling system of the alternative SEAFP reactor design. The LOFAs considered result from a loss of electrical power for the recirculation pump in the primary cooling circuit. The analyses have been performed using the thermal-hydraulic system analysis code RELAP5/MOD3. In the analyses, special attention has been paid to the transient thermal-hydraulic behaviour of the cooling system and the temperature development in the first wall and blanket. For the LOFA without plasma shutdown, significant loss of heat removal due to dryout occurs at the midplane of the outboard first wall cooling pipes about 41 s after pump trip. For the three LOFA cases with emergency plasma shutdown that have been studied, the temperature increase in the Be-coating at the midplane of the outboard first wall is ...

1994-07-01

257

Evaluation of pipe whip impacts on neighboring piping and walls of the Ignalina nuclear power plant.  

Energy Technology Data Exchange (ETDEWEB)

Presented in this paper is the transient analysis of a Group Distribution Header (GDH) following a guillotine break at the end of the header. The GDH is the most important component of reactor safety in case of accidents. Emergency Core Cooling System (ECCS) piping is connected to the GDH piping such that, during an accident, coolant passes from the GDH into the ECCS. The GDH that is propelled into motion after a guillotine break can impact neighboring GDH pipes or the nearest wall of the compartment. Therefore, two cases are investigated: GDH impact on an adjacent GDH and its attached piping; and GDH impact on an adjacent reinforced concrete wall. A whipping RBMK-1500 GDH along with neighboring concrete walls and pipelines is modeled using finite elements. The finite element code NEPTUNE used in this study enables a dynamic pipe whip structural analysis that accommodates large displacements and nonlinear material ...

2002-02-26

258

Visible Earth: Typhoon Aere  

Science.gov (United States)

NASA's Visible Earth catalog of NASA images and animations of our home planet.

261

Theoretical study of subwavelength imaging by acoustic metamaterial slabs  

CERN Document Server

We investigate theoretically subwavelength imaging by acoustic metamaterial slabs immersed in the liquid matrix. A near-field subwavelength image formed by evanescent waves is achieved by a designed metamaterial slab with negative mass density and positive modulus. A subwavelength real image is achieved by a designed metamaterial slab with simultaneously negative mass density and modulus. These results are expected to shed some lights on designing novel devices of acoustic metamaterials.

2009-01-01

265

Possibilities of rayleigh-taylor instability measurement by X-ray phase imaging  

International Nuclear Information System (INIS)

X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging

270

MR imaging of musculoskeletal trauma to the pelvis and the lower limb  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging can be used in the trauma setting to detect fractures and associated soft tissue injuries of the musculoskeletal system. Magnetic resonance imaging complements plain radiography and CT for evaluating cancellous bone, cartilage and growth-plate injuries, and intra- and extraarticular supporting soft tissue structures. This review outlines typical applications and imaging consideration for injuries of the pelvis and lower extremity. (orig.) With 12 figs., 78 refs.

1999-03-01

272

Lead-203 for skeletal imaging  

International Nuclear Information System (INIS)

... biological variability body distribution kidneys labelled compounds lead 203

273

Knowledge-based image analysis: some aspects on the analysis of images using other types of information  

Energy Technology Data Exchange (ETDEWEB)

The computer vision approach to image analysis is discussed from two aspects. First, this approach is constrasted to the pattern recognition approach. Second, how external knowledge and information and models from other fields of science and engineering can be used for image and scene analysis is discussed. In particular, the connections between computer vision and computer graphics are pointed out.

1982-01-01

275

Introduction to Three Dimensional Reconstruction of Brain C. T. Image  

International Nuclear Information System (INIS)

The reconstruction of coronal and Sagittal Image of Brain C. T. is helpful to diagnosis of Brain. Three Dimensional Reconstruction software package allows to display three dimensional Image clerived from a series of Horizontal, Sagittal and Coronal Brain C. T. images. It useful in determine approach of operation, to define portals of deep radiation therapy.

1986-11-01

283

Fundamental study on Fuji Computed Radiography (FCR) image  

International Nuclear Information System (INIS)

Japanese (Mar 1986). Japan Tomiyoshi, Tsukasa Kakoi, Iwao Fukushima,

1986-01-01

286

Eddy current imaging  

Energy Technology Data Exchange (ETDEWEB)

Image representations have gained wide acceptance in displaying data collected during optical, ultrasonic, radiographic, and thermographic inspections. Applying imaging techniques to eddy current testing is explored in this article. The authors show that flaw interpretation and characterization are made considerably simpler when images are used to visualize the impedance changes in eddy current probes.

1993-04-01

299

A submillimeter wavelength space-based imaging radar  

Science.gov (United States)

This report considers the use of a submillimeter wavelength space-based imaging radar. The main application envisioned is midcourse decoy discrimination for strategic defense, for which it would have the capability of producing a series of images, in real time, at strategic ranges, with less than meter scale resolution and with modest power requirements. Undoubtedly, there are other applications. The requirements for a SAR and ISAR imaging radar at submillimeter wavelength are determined, and the prospect for the development of RF sources to power the radar is examined.

1988-05-01

301

X-ray imaging dose due to the digital imaging devices used in radiation therapy for patient positioning and repositioning: How to take it into account?; Les doses dues a l'imagerie numerique pour le controle de positionnement du patient en radiotherapie: comment les prendre en compte?  

Energy Technology Data Exchange (ETDEWEB)

The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)

2008-12-15

302

Utilization of fractional Brownian motion in constrained least-squares restoration of medical images  

International Nuclear Information System (INIS)

Constrained least-squares techniques have been used to produce a well known class of image restoration algorithms. These techniques typically involve minimizing a linear operator on a vector representation of an image, subject to a constraint. For cases where an equality constraint is appropriate the method of Lagrange multipliers can be used to produce a restored image. In this work a fractal textural model, fractional Brownian motion, is used to represent images of interest. Using a variance fractal dimension estimator a non-linear operator, that represents the squared difference between the fractal dimension of the restored image and on a priori value is minimized, subject to the constraint that the norm of the residual between the restored image and available measurement equal the norm of the additive noise.

303

Document image retrieval with morphology-based segmentation and features combination  

Science.gov (United States)

Digital libraries need more than just a retrieval based on keywords, which can be inefficient for some applications. Thus, a document retrieval based on content of the digitized image version of the document can be a more appropriated approach. This paper discusses the retrieval of document images by means of identifying a variety of elements present in the document's image body. We propose a new strategy to identify and combine features extracted from a document image. We also consider the task of constructing an optimized feature set to improve the retrieval performance and to validate our experiments on an assorted database. Experimental results show that the proposed segmentation together with a wisely feature combination increase the overall retrieval performance. Moreover the retrieved images demonstrate the generality and effectiveness of our approach for an efficient ...

2011-01-01

304

Comparative evaluation of /sup 99m/Tc GH, /sup 99m/TcO_4, and /sup 99m/Tc DTPA as brain imaging agents  

International Nuclear Information System (INIS)

The brain imaging properties of /sup 99m/Tc glucoheptonate, /sup 99m/Tc pertechnetate, and /sup 99m/Tc DPTA are compared. Results demonstrate that optimum images are obtained at 90, 180, and 180 min., for /sup 99m/Tc GH, /sup 99m/Tc DTPA, and /sup 99m/Tc pertechnetate, respectively. The former two images are not affected by prior bone imaging with /sup 99m/Tc pyrophosphate, while /sup 99m/Tc pertechnetate images are adversely affected. /sup 99m/Tc glucoheptonate appears to be the superior agent for brain imaging, followed by /sup 99m/Tc DTPA and /sup 99m/Tc pertechnetate.

305

Subsurface imaging using the spectral polarization difference technique and NIR illumination  

Energy Technology Data Exchange (ETDEWEB)

A subsurface imaging system is utilized to test the ability of the spectral polarization difference imaging technique for deep subsurface imaging in tissues. The illumination of the system is derived from compact class III lasers in the red and NIR spectral region and, alternatively, from a white light source and selection of the appropriate illumination wavelength using band-pass optical filters. The experimental results demonstrate detection and imaging of a high-scattering object located up to 1.5 cm underneath the surface of a host chicken tissue.

1999-01-26

306

Cutaneous gallium uptake in patients with AIDS with mycobacterium avium-intracellulare septicemia  

International Nuclear Information System (INIS)

Gallium imaging is increasingly being used for the early detection of complications in patients with AIDS. A 26-year-old homosexual man who was HIV antibody positive underwent gallium imaging for investigation of possible Pneumocystis carinii pneumonia. Widespread cutaneous focal uptake was seen, which was subsequently shown to be due to mycobacterium avium-intracellulare (MAI) septicemia. This case demonstrates the importance of whole body imaging rather than imaging target areas only, the utility of gallium imaging in aiding the early detection of clinically unsuspected disease, and shows a new pattern of gallium uptake in disseminated MAI infection.

307

An overview of the development of the first wall and other principal components of a laser fusion power plant  

International Nuclear Information System (INIS)

This paper introduces the JNM Special Issue on the development of a first wall for the reaction chamber in a laser fusion power plant. In this approach to fusion energy a spherical target is injected into a large chamber and heated to fusion burn by an array of lasers. The target emissions are absorbed by the wall and encapsulating blanket, and the resulting heat converted into electricity. The bulk of the energy deposited in the first wall is in the form of X-rays (1.0-100 keV) and ions (0.1-4 MeV). In order to have a practical power plant, the first wall must be resistant to these emissions and suffer virtually no erosion on each shot. A wall candidate based on tungsten armor bonded to a low activation ferritic steel substrate has been chosen as the initial system to be studied. The choice was based on the vast experience with these materials in a nuclear environment and the ...

2005-12-15

308

Resolution enhancement by subtraction of confocal signals taken at different pinhole sizes.  

Science.gov (United States)

Subtractive imaging in confocal fluorescence light microscopy is based on the subtraction of a suitably weighted widefield image from a confocal image. An approximation to a widefield image can be obtained by detection with an opened confocal pinhole. The subtraction of images enhances the resolution in-plane as well as along the optic axis. Due to the linearity of the approach, the effect of subtractive imaging in Fourier-space corresponds to a reduction of low spatial frequency contributions leading to a relative enhancement of the high frequencies. Along the direction of the optic axis this also results in an improved sectioning. Image processing can achieve a similar effect. However, a 3D volume dataset must be acquired and processed, yielding a result essentially identical to subtractive imaging but superior in ...

2003-01-01

309

Magnified x-ray phase imaging using asymmetric Bragg reflection: Experiment and theory  

International Nuclear Information System (INIS)

X-ray imaging using asymmetric Bragg reflection in the hard x-ray regime opens the way to improve the spatial resolution limit below 1 #mu#m by magnifying the image before detection, simultaneously providing a strong phase contrast. A theoretical formalism of the imaging process is established. Based on this algorithm, numerical simulations are performed and demonstrate that both Fresnel propagation and Bragg diffraction contribute to contrast formation. The achievable resolution of this technique is investigated theoretically; the results obtained can be used to improve future experimental setups. Furthermore, the minimum detectable phase gradient is estimated, for comparison with other phase sensitive imaging techniques. Results from biological objects demonstrate that the technique is viable for imaging both in two and three dimensions. Refraction contrast ...

2006-08-01

310

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two ...

2007-01-01

311

Clinical trial of NMR-CT, (4). Clinical evaluation of hybrid image  

Energy Technology Data Exchange (ETDEWEB)

In our evaluation we utilized the Asahi Mark-J NMR-CT system, with a resistive vertical quadrupolar electromagnet (0.1 Tesla) and a proton resonance frequency of 4.5 MHz. Our main imaging methods are the inversion-recovery or IR, saturation-recovery, or SR, and calculated T/sub 1/. Difference, or D images, constructed by subtracting the data of the IR signal from that of the SR signal, have also been obtained in some cases. The system allows averaging of raw data. Hybrid images were constructed from two or more images to obtain clear definition of areas of interest. By using the hybrid image, several tissues of different relaxation times can be shown in the same image. Application in our study of the newly developed hybrid image indicates its importance in the detection and diagnosis of lesion, especially the detection of the differentiation ...

1985-01-01

312

WWER steam generator transients during loss of coolant accidents  

International Nuclear Information System (INIS)

A nonlinear mathematical model is presented of a WWER-440 nuclear power plant horizontal steam generator. On the proposed model is based a computer program for investigating transients in steam generators during loss of coolant accidents. Processes taking place at the primary side of the steam generator are described by a set of partial differential equations while those at the secondary side of the steam generator are described by plain differential equations with the variables being complex time functions. The model takes account of the coolant as both a single- and two-phase medium, of changes in the direction of the primary coolant flow and of changes in the direction of heat transfer. Heat transfer through the wall is based on a simple model of heat transfer through a thin-walled tube and includes a correction for the heat resistance of the wall. (author).

1978-01-01

313

The influence of furnace geometry and wall materials on the combustion process and the prediction of problem areas in waste incinerators  

Energy Technology Data Exchange (ETDEWEB)

Based on the CFD-code FLUENT trademark, theoretical studies were conducted of the influences of incineration chamber geometry (direct, countercurrent and center flow) on the combustion process. The boundary conditions, e.g., the thermal input and the waste grate, were kept constant. Close attention was paid to the distribution of flow, spe-cies, and temperatures. In addition, the influence of a dis-placement body at the end of the combustion chamber was tested. The variation of different wall materials and the prediction of problem areas concerning corrosion, slagging, and contamination completed the studies. Close to the chamber walls, high CO-concentrations may indi-cate corrosion; particle flow may indicate where contami-nation, slagging or erosion could occur. (orig.)

2001-01-01

314

Solar receiver-reactor with specularly reflecting walls for high-temperature thermoelectrochemical and thermochemical processes. Technical report  

Energy Technology Data Exchange (ETDEWEB)

A new kind of receiver-reactor for high-temperature solar furnaces is proposed. The main body of the receiver component is an ellipsoid of revolution with specularly reflecting inner walls. The reactor component, a crucible, is placed at one focal point and the aperture at the other. With this arrangement, substantially all of the incident radiation from the concentrator should reach the reactor directly or after one reflection from the cavity walls. An analysis of the radiative exchange among the surfaces is presented. The analysis provides a tool for a parametric study and optimization of the design. It is found that, in contrast to that of conventional well-insulated cavity receivers, its collection efficiency is not very sensitive to the size of its aperture.

1987-10-27

315

Post-CHF heat transfer with water and refrigerants  

Energy Technology Data Exchange (ETDEWEB)

Heat transfer experiments were performed in the post-CHF two-phase flow regime in a vertical tube. The tube inside diameter was 7.75 mm, and the boiling fluid was R-113. The experiments were performed at steady state by means of liquid heating of the test tube. Wall superheats were maintained below 70 C for heat exchanger/steam generator application. The mass flux range of the data was 379-816 kg m{sup -2} s{sup -1}. The use of R-113 significantly extended the property range of the existing low wall-superheat data base. Experimental data are presented in tabular as well as graphical form, and the results were used with low wall-superheat data from other fluids to add generality to a predictive heat transfer correlation. (orig.)

1996-06-01

316

Performance Evaluation of Several Types of Pulsed Eddy Current Probes for Detecting Wall Thickness Reduction  

Science.gov (United States)

In this paper, four different types of pulsed eddy current (PEC) probe are designed and their performance of detecting wall thickness reduction is compared. By using the backward difference method in time and the finite element method in space, PEC signals from various thickness and materials are numerically calculated and three features of the signal are selected. Since PEC signals and features are obtained by various types and sizes of probe, the comparison is made through the normalized features which reflect the sensitivity of the feature to thickness reduction. The normalized features indicate that the shielded reflection probe provides the best sensitivity to wall thickness reduction for all three signal features. Results show that the best sensitivity to thickness reduction is achieved by the peak value, but also suggest that the time to peak can be a good candidate because of its linear relationship with the thickness variation.

2010-02-01

317

Numerical simulation of slagging films in the Aachen pressurized coal combustion facility  

Energy Technology Data Exchange (ETDEWEB)

Combined gas and steam turbine processes based on direct coal firing show a high thermal efficiency. At RWTH Aachen, University of Technology, an experimental test furnace has been built to investigate the pressurized pulverized coal combustion (PPCC). The PPCC-facility has been constructed as a slag tap furnace. Particles hitting the walls at temperatures above the melting point cause slagging depositions and create a film flowing down the reactor walls. As a part of the PPCC-program different mathematical models have been developed and implemented into the CFD-code FLUENT to predict the behavior of slag films at the furnace walls. Numerical strategies and the mathematical models used are described in detail. 12 refs., 9 figs.

2001-07-01

318

Nomographs for the evaluation of the theoretical wall-thickness of cylinder shells without cutouts and branches and cylinder shells with an inclined single branch without additional thickening according to TRD 300/301 (loading condition: predominantly static internal compressive load)  

Energy Technology Data Exchange (ETDEWEB)

The evaluation of calculated values determined by means of the equations given in the TRD 300/301 standard resulted in two nomographs by which it is possible to find the theoretical wall thickness of cylinder shells without cutouts and branches as well as cylinder shells with an inclined or vertical single branch without additional thickening. The equations for the calculation of cylinder shells with an inclined single branch according to TRD 301 having only an iterative solution, the nomographs will be a considerable help for the engineering work. The determination of the theoretical wall-thickness from the nomographs is demonstrated by means of examples.

1981-06-01

319

Natural convection cooling of the IFMIF target and test cell  

International Nuclear Information System (INIS)

The present work summarizes efforts on the simulation of natural convection cooling within the IFMIF target and test cell. The simulations have been performed with the STAR-CD code using the k-#omega# high-Reynolds number turbulence model. A dedicated thermohydraulic model has been devised including Lithium loop components. Nuclear heat production has been calculated by the Monte-Carlo code McDeLicious for different parts of the target and test cell walls and was used as input for the STAR-CD simulations. Helium atmospheres at several pressures from 0.1 to 10"-"5 MPa have been investigated. In order to limit the maximum temperature of the concrete walls to 80 deg. C it was necessary to add thermal insulation layers to the hot Lithium loop surfaces and a conceptual system of two cooling layers in different depths of the concrete walls.

2007-10-01

320

Modification of the Gaussian dispersion equation to accommodate restricted lateral dispersion in deep river valleys  

Energy Technology Data Exchange (ETDEWEB)

Lateral plume dispersion in deep river valleys during neutral and stable lapse rate conditions can be exceptionally high due to the intense horizontal turbulence generated by prominent variations in the width, orientation and surface roughness of the valley walls. Use of the standard Gaussian dispersion equation to represent this enhanced lateral plume spread in a narrow valley may be inappropriate since consideration should also be given to the restriction of the horizontal plume spread due to impingement against the valley walls. The basic concept employed in the modification of the Gaussian dispersion equation was to assume that multiple eddy reflections occur between the valley walls in a manner similar to the vertical eddy reflections between the ground plane and an inversion layer aloft. The expressions are developed, but no attempt has been made to validate them with actual measured field data. 4 references, 3 ...

1986-02-01

321

Manufacture and first wall joining for an ITER primary wall module prototype: R and D phase with small scale mock-ups  

International Nuclear Information System (INIS)

In the frame of the Primary Wall Module prototype manufacturing for ITER, a consistent R and D phase was conducted in order to identify the industrial allowable tolerances and manufacturing problems which would occur when joining pieces by HIPping process during the PW module manufacturing. The purpose of this development was to give as industrial as possible manufacturing routes for joining together large Stainless Steel or DS-Copper pieces with Stainless Steel tubes and for bonding Beryllium tiles onto a curved component surface. The study concerned surface preparations, allowable gaps and joint geometry, Beryllium tile geometry, Titanium interlayer thickness, etc. This R and D phase also allowed the development and validation of different ultrasonic inspection tools needed for plate-plate, tube-plate, edge to edge plate bonding.

2001-10-01

322

Local heat transfer augmentation in channels with two opposite ribbed surfaces  

Science.gov (United States)

The local heat transfer coefficient distribution of a square channel with two opposite ribbed walls was determined. The square channel was connected to a sudden contraction entrance in order to simulate the inlet condition of the turbine blade cooling passages. The test channel was heated by thin stainless steel foils with a thickness of 0.000025 m, and instrumented with 180 thermocouples. The brass ribs of a square cross-section were glued periodically, in line, onto the top and bottom walls of the foil-heated channel in patterns to achieve the desired spacing and angle-of-attack. The local heat transfer coefficients on the smooth side and the ribbed side walls, at the channel entrance and the downstream regions, were measured for eight rib configurations and three Reynolds numbers (Re = 10,000, 30,000, and 60,000).

1986-01-01

323

General flow and thermal boundary conditions in indoor air flow simulation  

Energy Technology Data Exchange (ETDEWEB)

The concepts of general flow and thermal boundary conditions are introduced to treat the interaction between indoor and outdoor thermal environments in computational fluid dynamics (CFD) simulations. The results from a multi-zone model are used to supply the general flow boundary conditions. The energy balance equation at wall-air interfaces is used to supply the general thermal boundary conditions. An example calculation in a 13-room building shows that infiltration influences indoor air flow patterns considerably. The air flow in a room ventilated by displacement is measured and simulated. Two surface coatings are considered, i.e. black walls and aluminum walls. Implementation of these two boundary conditions is essential in predicting air flow patterns, air quality, and thermal comfort in a real building. (author)

1994-12-31

324

Filler metal development for Hastelloy alloy XR. Filler metal for hastelloy alloy XR structure with thick wall  

Energy Technology Data Exchange (ETDEWEB)

In order to develop the filler metal for Hastelloy alloy XR structure with thick wall, the weldability and high temperature strength properties of Hastelloy alloy XR weldment were investigated using the filler metals, which were alloy-designed on the basis of multiple regression analysis. The former was examined through the chemical analysis in the deposited metal, bend test, FISCO cracking test, optical microscopy and hardness measurement. The latter was investigated by means of tensile and creep test. It was found from these results that the crack susceptibility in the weldment was apparent to be lowered without degrading the high temperature strength properties. Therefore, it is concluded that these filler metals possess excellent performance as the filler metal for Hastelloy alloy XR structure with thick wall. (author).

1991-11-01

325

Effects of injection nozzle specifications on unburned HC during idling in a direct-injection diesel engine; Chokusetsu funshashiki diesel kikan no funsha nozzle shogen to idle untenji no HC  

Energy Technology Data Exchange (ETDEWEB)

The unburned HC in a direct-injection diesel engine is a cause of exhaust odor and SOF emission. Reduction of HC by changing the injection nozzle specifications was attempted in previous studies. In this study, some experiments in which the mixture formation was varied by using different hole diameters in a multihole nozzle and spray angles to the combustion chamber wall have been conducted. When the diameter of injection holes, which influences the fuel adhering to on the cylinder head walls and the combustion chamber wall, becomes smaller, the HC emission in the idling condition, HC deviation from cylinder to cylinder and HC increase with long idling time are decreased. The same effects were obtained by decreasing the diameter of all holes and by injecting the spray downward to the combustion chamber. 13 refs., 13 figs., 1 tab.

1996-02-25

326

Dosimetry of iodine-123 iomazenil in humans  

International Nuclear Information System (INIS)

The distribution of the central benzodiazepine receptor specific ligand iodine-123 iomazenil was investigated in seven human adults from whole-body scans, blood samples and urine collected up to 24 h after injection. Using 12 source organs, the MIRD method was applied to calculate the absorbed radiation dose of the radioligand in various organs. The urinary bladder wall (0.15 mGy/MBq), lower large intestinal wall (0.071 mGy/MBq) testes (0.044 mGy/MBq) and upper large intestined wall (0.038 mGy/MBq) received the highest absorbed doses. The average effective dose equivalent of "1"2"3I-IBZM for adults was estimated to be 0.033 mSv/MBq. (orig.).

327

Dielectric-wall linear accelerator with a high voltage fast rise time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators  

Energy Technology Data Exchange (ETDEWEB)

A dielectric-wall linear accelerator is improved by a high-voltage, fast rise-time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators. A high voltage is placed between the electrodes sufficient to stress the voltage breakdown of the insulator on command. A light trigger, such as a laser, is focused along at least one line along the edge surface of the laminated alternating layers of isolated conductors and insulators extending between the electrodes. The laser is energized to initiate a surface breakdown by a fluence of photons, thus causing the electrical switch to close very promptly. Such insulators and lasers are incorporated in a dielectric wall linear accelerator with Blumlein modules, and phasing is controlled by adjusting the length of fiber optic cables that carry the laser light to the insulator surface.

1998-01-01

328

Dielectric-wall linear accelerator with a high voltage fast rise time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators  

Energy Technology Data Exchange (ETDEWEB)

A dielectric-wall linear accelerator is improved by a high-voltage, fast rise-time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators. A high voltage is placed between the electrodes sufficient to stress the voltage breakdown of the insulator on command. A light trigger, such as a laser, is focused along at least one line along the edge surface of the laminated alternating layers of isolated conductors and insulators extending between the electrodes. The laser is energized to initiate a surface breakdown by a fluence of photons, thus causing the electrical switch to close very promptly. Such insulators and lasers are incorporated in a dielectric wall linear accelerator with Blumlein modules, and phasing is controlled by adjusting the length of fiber optic cables that carry the laser light to the insulator surface. 12 figs.

1998-10-13

329

Quantitative imaging of turbulent and reacting flows  

Energy Technology Data Exchange (ETDEWEB)

Quantitative digital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitative image data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial dynamic range, signal-to-noise ratio and ...

1993-12-01

330

Direct digital radiography vs conventional radiography of thoracic spine: a comparative study  

International Nuclear Information System (INIS)

Objective: An evaluation of the application of DR in thoracic spine and a comparative study of the DR with the conventional radiography. Methods: DR images and the conventional radiogram of 89 cases respectively were evaluated by 3 vice-consultant doctors and 2 chief technicians. Statistics was processed with 2 categories: (1) images were classified into grade A, B, C and condemned according to the image quality; and (2) thoracic spine are divided into upper, middle and lower portions, in which the rate of successful imaging were compared respectively. Results: The image quality of DR: 74. 1% images in grade A, 20.2% in grade B, 5.7% in grade C, and no image condemned. Conventional radiogram: 45% images in grade A, 41.6% in grade B, 11.2% in grade C, and 2.2% images condemned. The successful ...

2005-09-01

331

Advantages of magnification in digital phase-contrast mammography using a practical X-ray tube  

Energy Technology Data Exchange (ETDEWEB)

Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point source results in a phase contrast too narrow for detection with CR. In addition to phase ...

2008-12-15

332

X-ray Phase Imaging Microscopy using a Fresnel Zone Plate and a Transmission Grating  

International Nuclear Information System (INIS)

We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.

2010-06-23

333

Tracheal images using energy subtraction Fuji computed radiography  

International Nuclear Information System (INIS)

Twenty patients with lesions in the trachea or bronchus underwent energy subtraction Fuji computed radiography (FCR). Images obtained were compared with those from conventional FCR (plain FCR). ''Very clear'' images (in which the contour of the trachea and bronchus could be clearly defined) were obtained in 12/22 (55 %) by energy subtraction FCR and in 3/22 (14 %) by plain FCR; ''clear'' images (in which the contour could be defined) in 9/22 (41 %) by energy subtraction FCR and in 18/22 (82 %) by plain FCR; and ''unclear'' images (in which the contour could not be defined) in 1/22 (5 %) by both methods. Energy subtraction FCR, as well as plain FCR, yielded high image quality for the trachea. Energy subtraction FCR was superior to plain films when tumors existed within the trachea. (Namekawa, K.).

1985-01-01

334

The Adrenal Mass: Correlation of Histopathology with Imaging  

British Library Electronic Table of Contents (United Kingdom)

Background Computed tomography (CT) and magnetic resonance (MR) imaging can help diagnose benign adrenal adenomas, but prior studies rely on nonoperative follow-up as proof of a lesion?s benign nature. We examined adrenalectomy tissues to determine if imaging characteristics correlate with histopathologic findings. Methods We retrieved data for 196 consecutive adrenalectomies in 192 patients from 2000 to 2008. Imaging results were considered to signify benign adrenal adenoma if one or more of the following was present: Hounsfield units 60% or relative contrast washout of >40%, or MR with chemical-shift imaging demonstrating loss of signal intensity on out-of-phase images. Results The sensitivity and specif...

2010-01-01

335

Real time neutron radioscopy - trends and applications  

International Nuclear Information System (INIS)

Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor

2003-11-12

336

Position sensitive detection of individual nuclear particle scintillations using image intensifier tubes  

International Nuclear Information System (INIS)

An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).

1996-01-01

337

Parallel architecture for rapid image generation and analysis  

Energy Technology Data Exchange (ETDEWEB)

A multiprocessor architecture inspired by the Disney multiplane camera is proposed. For many applications, this approach produces a natural mapping of processors to objects in a scene. Such a mapping promotes parallelism and reduces the hidden-surface work with minimal interprocessor communication and low-overhead cost. Existing graphics architectures store the final picture as a monolithic entity. The architecture here stores each object's image separately. It assembles the final composite picture from component images only when the video display needs to be refreshed. This organization simplifies the work required to animate moving objects that occlude other objects. In addition, the architecture has multiple processors that generate the component images in parallel. This further shortens the time needed to create a composite picture. In addition to generating images for animation, the ...

1987-01-01

338

Neutron imaging system for neutron tomography, radiography, and beam diagnostics  

Energy Technology Data Exchange (ETDEWEB)

A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.

1995-12-31

339

Magnetization transfer contrast effect on multislice fast spin echo  

Energy Technology Data Exchange (ETDEWEB)

Magnetization transfer contrast (MTC) on fast spin echo (FSE) images was evaluated in normal brain tissue as well as in brain tumors to better understand contrast of FSE images. On multislice FSE images, attenuation of the signal intensity of brain tissue due to MTC is observed. The rate of MTC (MTR) is obtained by comparing with additional single slice images. The effect of signal attenuation is greater on images with smaller interslice gap, larger number of slices, and longer echo train length. MTR of brain tumors is less than that of normal brain tissue. Among them, meningiomas have relatively high MTR, and cavernous malformation has relatively low MTR. Determination of MTC can be easily specified by obtaining multislice and single slice FSE images, and it may help differentiate brain tumors. (author).

1994-03-01

340

Field test studies of our infrared-based human temperature screening system embedded with a parallel measurement approach  

British Library Electronic Table of Contents (United Kingdom)

This paper introduces a parallel measurement approach for fast infrared-based human temperature screening suitable for use in a large public area. Our key idea is based on the combination of simple image processing algorithms, infrared technology, and human flow management. With this multidisciplinary concept, we arrange as many people as possible in a two-dimensional space in front of a thermal imaging camera and then highlight all human facial areas through simple image filtering, image morphological, and particle analysis processes. In this way, an individual's face in live thermal image can be located and the maximum facial skin temperature can be monitored and displayed. Our experiment shows a measured 1ms processing time in highlighting all human face areas. With a thermal imaging ca...

2009-01-01

341

Feasibility study of the iterative x-ray phase retrieval algorithm  

International Nuclear Information System (INIS)

An iterative phase retrieval algorithm was previously investigated for in-line x-ray phase imaging. Through detailed theoretical analysis and computer simulations, we now discuss the limitations, robustness, and efficiency of the algorithm. The iterative algorithm was proved robust against imaging noise but sensitive to the variations of several system parameters. It is also efficient in terms of calculation time. It was shown that the algorithm can be applied to phase retrieval based on one phase-contrast image and one attenuation image, or two phase-contrast images; in both cases, the two images can be obtained either by one detector in two exposures, or by two detectors in only one exposure as in the dual-detector scheme.

2009-01-01

342

Extraction methods of phase information for X-ray diffraction enhanced imaging  

Energy Technology Data Exchange (ETDEWEB)

X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more ...

2007-08-21

343

Extraction methods of phase information for X-ray diffraction enhanced imaging  

International Nuclear Information System (INIS)

X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more precision of ...

2007-08-21

344

Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)  

Energy Technology Data Exchange (ETDEWEB)

Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best ...

1991-12-01

345

Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)  

International Nuclear Information System (INIS)

Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical ...

1991-01-01

346

Development of the high sensitivity real-time neutron radiography for low-flux neutron sources  

Energy Technology Data Exchange (ETDEWEB)

The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose ...

1994-08-01

347

Development of the high sensitivity real-time neutron radiography for low-flux neutron sources  

International Nuclear Information System (INIS)

The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose ...

1994-01-01

348

A new method of imaging particle tracks in solid state nuclear track detectors  

British Library Electronic Table of Contents (United Kingdom)

Summary Solid state nuclear track detectors are used to determine the concentration of a particles in the environment. The standard method for assessing exposed detectors involves 2D image analysis. However 3D imaging has the potential to provide additional information relating to angle as well as to differentiate clustered hit sequences and possibly energy of a particles but this could be time consuming. Here we describe a new method for rapid high-resolution 3D imaging of solid state nuclear track detectors. A `LEXT' OLS3100 confocal laser scanning microscope (Olympus Corporation, Tokyo, Japan) was used in confocal mode to successfully obtain 3D image data on four CR-39 plastic detectors. Three-dimensional visualization and image analysis enabled characterization of track features. This ...

2010-01-01

349

ITER Blanket First Wall (WBS 1.6{sub 1}A)  

Energy Technology Data Exchange (ETDEWEB)

International Thermonuclear Experimental Reactor (ITER) project is the international collaboration one for the commercialization of nuclear fusion energy through the technical and engineering verification. In ITER project, we plan to procure the blanket systems which has the risk of technology and cost when it is newly developed. We are developing the manufacturing process and joining technology for the ITER blanket to complete the procurement with qualified blanket system. To evaluate the soundness of manufacturing process, specimen and mock-up tests are being prepared. Finally, we can obtain the key technology of nuclear fusion reactor especially on the blanket design, joining and manufacturing technology through the present project and these technologies will help the construction of Korea fusion DEMO reactor and the development of commercial nuclear fusion reactor in Korea. In 1st year, through the fabrication of the Cu/SS and Be/Cu joint specimen, fabrication procedure such as ...

2008-03-15

350

Turbulent wall pressure and wall shear fluctuations calculated from the Orr-Sommerfeld equation with nonlinear forcing terms  

Energy Technology Data Exchange (ETDEWEB)

The wavenumber-frequency spectral densities of turbulent wall pressure fluctuations are investigated over a rigid flat plate. Nonlinear Reynolds stress terms of the inhomogeneous Orr-Sommerfeld equation are regarded as a known forcing function. The forcing function is modeled after Bark{close_quote}s hydrodynamic bursting formulation. The inhomogeneous Orr-Sommerfeld equation is solved by the method of Eckhaus in terms of discrete homogeneous solutions. The method of Eckhaus is then extended and proved for the continuous Orr-Sommerfeld eigenfunctions. Turbulent wall pressure fluctuations in terms of wavenumber-frequency spectral densities are numerically computed and compared to the experimental results of Martin as well as to his transformation of Blake{close_quote}s data fitted to a modified Corcos model. The wavenumber-frequency spectral densities numerically computed from the discrete eigenfunctions compared well with Martin{close_quote}s ...

1996-06-01

351

The supply of small scale mock-ups of the primary wall module concepts for ITER  

International Nuclear Information System (INIS)

The present design of Blanket Shield and Primary Wall for ITER envisages construction of the wall with a water cooled, stainless steel outer layer and a water cooled, copper liner on the inside plasma facing surface. Protection of the inner copper surface with an armour layer is necessary to cope with plasma to wall interaction. There are a number of armour materials under consideration, for this project beryllium was used. The scope of work was to produce a series of mock-ups, each consisting of a different combination of materials, which included Dispersion Strengthened Copper, Copper-Chrome-Zirconium alloy, Beryllium and Stainless Steel. Hot Isostatic Pressing (HIP) was the method used to ensure that a fully diffused bonded joint was achieved giving the necessary strength and thermal conductivity. The first five of the mock ups have been successfully completed and are being tested at the various laboratories in Europe. ...

1998-09-07

352

The L-type calcium channel inhibitor diltiazem prevents cardiomyopathy in a mouse model  

UK PubMed Central (United Kingdom)

Dominant mutations in sarcomere protein genes cause hypertrophic cardiomyopathy, an inherited human disorder with increased ventricular wall thickness, myocyte hypertrophy, and disarray. To understand...Full Text Available

2002-04-15

353

Sortases and the Art of Anchoring Proteins to the Envelopes of Gram-Positive Bacteria  

UK PubMed Central (United Kingdom)

The cell wall envelopes of gram-positive bacteria represent a surface organelle that not only functions as a cytoskeletal element but also promotes interactions between bacteria and their environment....Full Text Available

2006-03-01

354

Smooth Muscle Hypertrophy Following Partial Bladder Outlet Obstruction Is Associated with Overexpression of Non-Muscle Caldesmon  

UK PubMed Central (United Kingdom)

Partial bladder outlet obstruction (PBOO) induces remodeling of urinary bladder smooth muscle (detrusor). We demonstrate an increase in bladder wall mass, muscle bundle size, and a threefold increase...Full Text Available

2004-02-01

355

Role of the sar locus of Staphylococcus aureus in induction of endocarditis in rabbits.  

UK PubMed Central (United Kingdom)

A regulatory locus on the Staphylococcus aureus chromosome, designated sar, is involved in the expression of cell wall proteins, some of which are potentially important in the pathogenesis of endocarditis....Full Text Available

1994-05-01

356

Remote environmental monitoring at No. 26 Colliery  

Energy Technology Data Exchange (ETDEWEB)

The author describes the layout of the environmental monitoring scheme at Devco's No. 26 Colliery in Canada, which includes wall face ventilation, fan performance, and methane drainage monitoring. He gives details of the sensors, outstations, and the surface control room.

1982-03-01

357

Radiation modification of vascular prostheses  

International Nuclear Information System (INIS)

The radiation method has been employed for the modification of the surface of vascular prostheses by means of acrylamide. As a result of the treatment, the tightness of the prosthesis walls was improved as well as an increase of surface hydrophilicity. Upon autoclaving, stable binding of polyacrylamide to prostheses is achieved. (author).

358

Properties of a cell-wall-defective variant of Brucella abortus of bovine origin.  

UK PubMed Central (United Kingdom)

The properties of an atypical Brucella strain isolated from lymph node tissue of a cow slaughtered as a brucellosis reactor were examined. The organism was Gram negative and highly pleomorphic, existing...Full Text Available

1980-08-01

359

Phosphorylation of the Mycobacterium tuberculosis ?-Ketoacyl-Acyl Carrier Protein Reductase MabA Regulates Mycolic Acid Biosynthesis*  

UK PubMed Central (United Kingdom)

Mycolic acids are key cell wall components for the survival, pathogenicity, and antibiotic resistance of the human tubercle bacillus. Although it was thought that Mycobacterium tuberculosis...Full Text Available

2010-04-23

360

Optimizing the design of solar energy greenhouses  

Energy Technology Data Exchange (ETDEWEB)

In Canada, the cost of heating is a major expense in the operation of greenhouses in the winter season, inhibiting greenhouse production in winter months in most part of the country. Alternative energy sources, such as solar energy and biomass energy may offer an economically feasible heating alternative. A solar energy greenhouse technology developed in northern China for winter vegetable production has demonstrated good potential for Manitoba winter conditions. The design and performance of solar energy greenhouses depend on the geographical location. Therefore, in order to optimize the design of solar greenhouses with respect to the latitude of the location for maximum solar radiation gain, a theoretical analysis was performed that analyzed parameters such as greenhouse length and the roof slope. This paper described the methodology of the study, including a description of solar energy greenhouses; the energy of solar radiation; shading of the north roof; shading of the end ...

2006-07-01

361

Massive encapsulation of larval Anguillicoloides crassus in the intestinal wall of Japanese eels  

UK PubMed Central (United Kingdom)

BackgroundWithin the last 25 years, after the introduction of the swimbladder nematode Anguillicoloides crassus from East-Asia to Europe, a body of work has aggregated...Full Text Available

362

Malignant gastrointestinal stromal tumor presenting with hemoperitoneum in puerperium: report of a case with review of the literature  

UK PubMed Central (United Kingdom)

BackgroundGastrointestinal stromal tumors (GISTs) are mesenchymal tumors that develop in the wall of the gastrointestinal tract and their diagnosis during pregnancy or puerperium...Full Text Available

363

Luetic aortopathy: Revisited  

UK PubMed Central (United Kingdom)

We report a case of 38-year-old male, who presented with a large pulsatile swelling on the left side of the anterior chest wall of 4 months’ duration with a gradual increase in size. He gave...Full Text Available

2010-07-01

364

Induction of autolysis in nongrowing Escherichia coli.  

UK PubMed Central (United Kingdom)

Unless relaxation of the stringent response is achieved, all nongrowing bacteria rapidly develop resistance to autolysis induced by a variety of agents, including all classes of cell wall synthesis...Full Text Available

1986-09-01

365

Increased endothelial and vascular smooth muscle cell adhesion on nanostructured titanium and CoCrMo  

UK PubMed Central (United Kingdom)

In the body, vascular cells continuously interact with tissues that possess nanostructured surface features due to the presence of proteins (such as collagen and elastin) embedded in the vascular wall....Full Text Available

2006-03-01

366

High resolution scanning electron microscopy of plasmodesmata.  

Science.gov (United States)

Symplastic transport occurs between neighbouring plant cells through functionally and structurally dynamic channels called plasmodesmata (PD). Relatively little is known about the composition of PD or the mechanisms that facilitate molecular transport into neighbouring cells. While transmission electron microscopy (TEM) provides 2-dimensional information about the structural components of PD, 3-dimensional information is difficult to extract from ultrathin sections. This study has exploited high-resolution scanning electron microscopy (HRSEM) to reveal the 3-dimensional morphology of PD in the cell walls of algae, ferns and higher plants. Varied patterns of PD were observed in the walls, ranging from uniformly distributed individual PD to discrete clusters. Occasionally the thick walls of the giant alga Chara were fractured, revealing the surface morphology of PD within. External structures such as spokes, spirals and mesh ...

2011-05-28

367

Heat Transfer Augmentation in a Compact Heat Exchange Pedestal Array.  

Science.gov (United States)

A compact heat exchanger pedestal array for augmenting heat transfer in a machine is disclosed. The compact heat exchanger pedestal array includes a wall having first and second surfaces. The first surface faces a heated flow path and the second surface p...

2004-01-01

368

Gas Turbine Blade Heat Transfer Augmentation by Impingement of Air Jets Having Various Configurations.  

Science.gov (United States)

An experimental investigation of heat transfer characteristics for various configurations of air jets impinging on the leading edge inner surface of a gas turbine blade wall is presented. Three configurations were investigated, namely a slot jet, a round ...

1970-01-01

369

Functional and Structural Analysis of a Key Region of the Cell Wall Inhibitor Moenomycin  

UK PubMed Central (United Kingdom)

Moenomycin A (MmA) belongs to a family of natural products that inhibit peptidoglycan biosynthesis by binding to the peptidoglycan glycosyltransferases (PGTs), the enzymes that make the glycan...Full Text Available

2010-07-16

370

Energy-resolved electron particle and energy fluxes in positive column plasmas  

Energy Technology Data Exchange (ETDEWEB)

This paper deals with electron flux densities and electron energy flux densities in positive column discharges. Recent kinetic calculations by Uhrlandt and Winkler have revealed the interesting physical phenomenon of radially inward directed energy flux densities in positive column plasmas. We have used a self-consistent positive column model, based on an accurate and highly detailed Monte Carlo code, to study this effect in more depth. The results of this study show a rather complex physical picture of electron particle and energy flux densities. Electrons with low energies usually exhibit radially outward directed particle and energy flux densities. At energies above the threshold for electronic excitation particle and energy flux densities are usually inward directed. Only close to the wall, at total energies above the wall potential energy, do these flux densities point towards the wall. The thickness of this ...

1999-11-07

371

Development and Application of Pathovar-Specific Monoclonal Antibodies That Recognize the Lipopolysaccharide O Antigen and the Type IV Fimbriae of Xanthomonas hyacinthi  

UK PubMed Central (United Kingdom)

The objective of this study was to develop a specific immunological diagnostic assay for yellow disease in hyacinths, using monoclonal antibodies (MAbs). Mice were immunized with a crude cell wall preparation...Full Text Available

1999-09-01

372

Determination of bilayer membrane bending stiffness by tether formation from giant, thin-walled vesicles.  

UK PubMed Central (United Kingdom)

The curvature elastic modulus (bending stiffness) of stearoyloleoyl phosphatidylcholine (SOPC) bilayer membrane is determined from membrane tether formation experiments. R. E. Waugh and R. M. Hochmuth...Full Text Available

1989-03-01

373

Cytokine signalling in rat pulp interstitial fluid and transcapillary fluid exchange during lipopolysaccharide-induced acute inflammation  

UK PubMed Central (United Kingdom)

The dental pulp consists of loose connective tissue encased in rigid dentinal walls. Because of its topography the tissue has low interstitial compliance and limited capacity to expand during fluid...Full Text Available

2006-05-15

374

Comparative Evaluation of Nanofibrous Scaffolding for Bone Regeneration in Critical-Size Calvarial Defects  

UK PubMed Central (United Kingdom)

In a previous study we found that nanofibrous poly(l-lactic acid) (PLLA) scaffolds mimicking collagen fibers in size were superior to solid-walled scaffolds in promoting osteoblast differentiation...Full Text Available

2009-08-01

375

Chest Wall Resection for Adult Soft Tissue Sarcomas and Chondrosarcomas: Analysis of Prognostic Factors  

UK PubMed Central (United Kingdom)

BackgroundWide resection with tumor-free margins is necessary in soft-tissue sarcomas to minimize local recurrence and to contribute to long-term survival. Information about treatment...Full Text Available

2011-01-01

376

Arabidopsis thaliana auxotrophs reveal a tryptophan-independent biosynthetic pathway for indole-3-acetic acid.  

UK PubMed Central (United Kingdom)

We used tryptophan auxotrophs of the dicot Arabidopsis thaliana (wall cress) to determine whether tryptophan has the capacity to serve as a precursor to the auxin, indole-3-acetic acid (IAA). Quantitative...Full Text Available

1993-11-01

377

Antifungal thiopeptide cyclothiazomycin B1 exhibits growth inhibition accompanying morphological changes via binding to fungal cell wall chitin  

British Library Electronic Table of Contents (United Kingdom)

Cyclothiazomycin B1 (CTB1) is an antifungal cyclic thiopeptide isolated from the culture broth of Streptomyces sp. HA 125-40. CTB1 inhibited the growth of several filamentous fungi including plant pathogens along with swelling of hyphae and spores. The antifungal activity of CTB1 was weakened by hyperosmotic conditions, and hyphae treated with CTB1 burst under hypoosmotic conditions, indicating increased cell wall fragility. CTB1-sensitive fungal species contain high levels of cell wall chitin and/or chitosan. Unlike nikkomycin Z, a competitive inhibitor of chitin synthase (CHS), CTB1 did not inhibit CHS activity. Although CTB1 inhibited CHS biosynthesis, the same result was also obtained with a non-specific proteins inhibitor, cycloheximide, which did not reduce cell wall rigidity. These ...

2011-01-01

378

Angiomatoid giant cellular blue nevus of vaginal wall associated with pregnancy  

UK PubMed Central (United Kingdom)

BackgroundBlue nevi that arise from the Müllerian tract are rare melanocytic lesions. Several histopathologic variants of cellular blue nevi have been described. The angiomatoid...Full Text Available

379

Anatomical Reasons for the Discrepancies in Atrioventricular Block after Inferior Myocardial Infarction with and without Right Ventricular Involvement  

UK PubMed Central (United Kingdom)

The incidence of arrhythmias after acute myocardial infarction of the inferior wall varies with the affected segment and increases when there is right ventricular involvement. This paper provides a...Full Text Available

2009-01-01

380

Activation calculations using an expanded data base  

Energy Technology Data Exchange (ETDEWEB)

Using an expanded nuclear data base, the activation of nitrogen, aluminum, iron, nickel, copper, zirconium, niobium, molybdenum, tungsten, and lead were calculated for the first wall positions of the STARFIRE and MARS conceptual fusion reactors.

1986-04-01

381

A heating tube  

Energy Technology Data Exchange (ETDEWEB)

Hollow needles made of an electrically conducting material are attached by hinges in the openings of the perforated end of an insert in order to intensify heat and mass transfer. The free sections of the needles are placed outside the insert, and a wick is placed on the wall of the frame in the condensation area. The wick overlaps the inlet openings of the insert.

1980-09-23

382

10 - NASA Technical Reports Server  

Science.gov (United States)

Mar 1, 2011 ... The most interesting flow characteristics observed were the occasional appearance of steady, ... pressure gradient, rather than wall divergence angle, controlled flow separation. ... Report/Patent Number: AGARD-AG-19/P9 ...

383

Pulmonary nodule detection of chest phantom with CRT images; Comparison with conventional radiography (film-screen system) and FCR hardcopy  

Energy Technology Data Exchange (ETDEWEB)

Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and ...

1989-08-01

384

Pulmonary nodule detection of chest phantom with CRT images  

International Nuclear Information System (INIS)

Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and ...

1989-01-01

385

Two-phase Flow Regime Maps in Horizontal and Vertical Tubes  

Energy Technology Data Exchange (ETDEWEB)

A safety analysis code to design a pressurized water reactor and to obtain the licenses including entire proprietary rights is under development in domestic R and D project. The tasks of KAERI is to develop the constitutive relations including models for defining flow regimes and flow regime related models for inter-phase friction, wall frictions, wall heat transfer, and interphase heat and mass transfer in the two-phase three-field equations. In this paper, the process will be presented for choosing the best flow regime maps which occur in gas-liquid two-phase flow in horizontal and vertical tubes.

2007-10-15

386

Two-phase Flow Regime Maps in Horizontal and Vertical Tubes  

International Nuclear Information System (INIS)

A safety analysis code to design a pressurized water reactor and to obtain the licenses including entire proprietary rights is under development in domestic R and D project. The tasks of KAERI is to develop the constitutive relations including models for defining flow regimes and flow regime related models for inter-phase friction, wall frictions, wall heat transfer, and interphase heat and mass transfer in the two-phase three-field equations. In this paper, the process will be presented for choosing the best flow regime maps which occur in gas-liquid two-phase flow in horizontal and vertical tubes.

2007-10-01

387

Transverse Resistive Wall Wakefunction with Inductive Bypass  

CERN Document Server

Charged particle beams in circular accelerators couple with their surroundings through induced electromagnetic fields. This interaction can be described by so-called coupling impedances. In the frequency domain the impedance in connection with the bunch spectrum allows for stability analysis and estimates. However, for simulation codes one usually needs the wakefunction, the equivalent of the impedance in time domain. Recently the transverse impedance of a cylindrical pipe with arbitrary surface impedance was given by L. Vos. An expression for the wakefunction of this transverse resistive wall impedance with inductive bypass is derived here.

2003-01-01

388

Torsion of moderately thick hollow tubes with polygonal shapes  

British Library Electronic Table of Contents (United Kingdom)

A simple formulation is presented for torsion analysis of hollow tubes with polygonal shapes. Thicknesses of segments of cross section can be different. Governing equations in term of Prandtl's stress function are used to derive the formulas. The derived formulas are so simple that computations can be carried out with a pocket calculator. Several examples are presented to show the accuracy and efficiency of the formulation. The obtained results are verified by accurate finite element solutions. It will be seen that the derived formulas can be useful for analysis of thin-walled and moderately thick-walled hollow tubes.

2007-01-01

389

The natural convection cooling with vaporizing deuterium for the horizontally arranged cold neutron source of the HFR - Grenoble  

International Nuclear Information System (INIS)

Natural convection of vaporizing Deuterium at 25 K transports the heat generated in the moderator cell of the cold neutron source to a He cooled condenser. The thermohydraulics of this thermosiphon were precalculated and the results verified by experiments in a 1:1 model using D_2 as fluid. The experimental results show that the thermosiphon operates stable. The demanded liquid content of the cell as well as wall temperatures below 50 K can be ensured by a proper design of the cell outlet flow geometry. A 7 min. loss of cryogenic power results in transient temperatures of the cell wall of not more than 300 K.

1991-08-01

390

Summary of Uranium City, Saskatchewan remedial measures for radiation reduction with special attention to vent fan theory  

International Nuclear Information System (INIS)

Various remedial measures have been tried to lower radon levels in buildings in Uranium City. The methods used are source material removal, passive ventilation of crawl spaces, sub-floor ventilation, complete epoxy coating of the entire basement, sealants for floor-wall joints and cracks in basements, electrostatic precipitators, mechanical ventilation, and sealing and grouting concrete block plenums in basement walls. The type and condition of structures encountered in Uranium City as well as the relative isolation of the town indicate that mechanical ventilation is the most long-term cost-effective method.

1980-03-12

391

Spiral CT with three-dimensional and multiplanar reconstruction in the diagnosis of anterior chest wall joint and bone disorders  

Energy Technology Data Exchange (ETDEWEB)

Twenty-seven patients with symptoms or clinical findings suggesting joint or bone disorders of the anterior chest wall (ACW) were evaluated by spiral CT with 3-dimensional (3-D) and multiplanar reconstructions. Preceding conventional ACW tomography was performed in 10 patients. ACW joint and bone changes were visualized more adequately by coronal 2-D reconstructions based on spiral CT than by conventional tomography. In addition, nonossified costal cartilages and soft tissue lesions were demonstrated. 3-D reconstructions sometimes added information, especially in patients with fracture and dislocation. (orig.).

1994-09-01

392

Solar energy receiver for a Stirling engine  

Energy Technology Data Exchange (ETDEWEB)

A solar energy receiver is described including a separable endless wall formed of a ceramic material having defined therein a cavity of a substantially cylindrical configuration for entrapping solar flux, and an acceptance aperture adapted to admit to the cavity a concentrated beam of solar energy, said wall being characterized by at least a pair of contiguously related segments separated by lines of cleavage intercepting said aperture, at least one of the segments being supported for pivotal displacement, and a thermal responsive actuator adapted to respond to excessive temperatures within the cavity for initiating pivotal displacement of said one segment, whereby thermal flux is permitted to escape from the cavity.

1980-12-02

393

Numerical prediction of flow field and particle trajectory in a hard disk drive  

Energy Technology Data Exchange (ETDEWEB)

A flow field and particle trajectory in a HDD (Hard Disk Drive) between two rotating disks in axisymmetric enclosures is investigated using CFD code FLUENT/UNS. The RNG k-{epsilon} model is used as a turbulent model. In this study, the flow field between two disks are symmetric, and the flow field near the enclosure is very complex. Cross stream vectors are shown both for blowing and no blowing from the hub. The larger a particle, the more fast the particle deposits at the walls. In the case of blowing from the hub, the more fast the particle deposits at the walls. (author). 9 refs., 12 figs., 1 tab.

1999-11-01

394

Mechanism of biodegradation of paraquat by Lipomyces starkeyi  

Energy Technology Data Exchange (ETDEWEB)

The biodegradation of ring-/sup 14/C- and methyl-/sup 14/C-labeled paraquat by the soil yeast Lipomyces starkeyi was studied in vitro. It was found that the degradation of paraquat (acting as a sole source of culture nitrogen) resulted in the accumulation in the extracellular medium of radiolabeled acetic acid. The culture also evolved radiolabeled CO/sub 2/. The results suggest that the degradation of paraquat by L. starkeyi is associated with the integrity of the cell wall and that disruption or removal of the wall results in a complete loss of degradative capability. A mechanism for the degradation of paraquat by this organism is postulated.

1985-05-01

395

Mechanism of biodegradation of paraquat by Lipomyces starkeyi  

International Nuclear Information System (INIS)

The biodegradation of ring-"1"4C- and methyl-"1"4C-labeled paraquat by the soil yeast Lipomyces starkeyi was studied in vitro. It was found that the degradation of paraquat (acting as a sole source of culture nitrogen) resulted in the accumulation in the extracellular medium of radiolabeled acetic acid. The culture also evolved radiolabeled CO_2. The results suggest that the degradation of paraquat by L. starkeyi is associated with the integrity of the cell wall and that disruption or removal of the wall results in a complete loss of degradative capability. A mechanism for the degradation of paraquat by this organism is postulated.

396

Low emissions compression ignited engine technology  

Energy Technology Data Exchange (ETDEWEB)

A method and apparatus for operating a compression ignition engine having a cylinder wall, a piston, and a head defining a combustion chamber. The method and apparatus includes delivering fuel substantially uniformly into the combustion chamber, the fuel being dispersed throughout the combustion chamber and spaced from the cylinder wall, delivering an oxidant into the combustion chamber sufficient to support combustion at a first predetermined combustion duration, and delivering a diluent into the combustion chamber sufficient to change the first predetermined combustion duration to a second predetermined combustion duration different from the first predetermined combustion duration.

2007-04-03

397

Investigation of Two-Phase Flow Regime Maps for Development of Thermal-Hydraulic Analysis Codes  

Energy Technology Data Exchange (ETDEWEB)

This reports is a literature survey on models and correlations for determining flow pattern that are used to simulate thermal-hydraulics in nuclear reactors. Determination of flow patterns are a basis for obtaining physical values of wall/interfacial friction, wall/interfacial heat transfer, and droplet entrainment/de-entrainment. Not only existing system codes, such as RELAP5-3D, TRAC-M, MARS, TRACE, CATHARE) but also up-to-date researches were reviewed to find models and correlations

2010-04-15

398

Heat transfer characteristics of laminar flow in internally finned tubes under various boundary conditions  

Science.gov (United States)

Numerical solutions for fully developed laminar flow in internally finned tubes with trapezoidal and triangular fin profiles were given with Finite Element Method (FEM): The heat transfer characteristics were obtained and compared under the boundary conditions of uniform heat flux, uniform wall temperature, and the third boundary condition with finite wall thermal conductivity considered. The numerical results show that boundary conditions have pronounced effects on the temperature field. Furthermore, a new mechanism on the heat transfer augmentation of internally finned tubes is proposed.

1994-06-01

399

Free convection heat and mass transfer to steady flow in a semi-infinite vertical porous medium  

International Nuclear Information System (INIS)

Analytical solutions are derived for a flow in a semi-infinite vertical porous medium with heat and mass transfer. When the temperature and mass concentration are uniform a constant pressure is possible and sustains a fully developed flow. Thereafter there is a small perturbation on the wall temperature and concentration and the subsequent two-dimensional problem is tackled for a large Prandtl number, free convection parameters and small Reynolds number. The heat transfer rate at the wall is discussed quantitatively. (author). 4 refs.

2010-06-01

400

Flow Regime Map Models for the Horizontal and Vertical Pipes for the SPACE code  

Energy Technology Data Exchange (ETDEWEB)

A safety analysis code, named as SPACE, for a pressurized water reactor is under development to obtain a licensing to be used for the PWR design and to hold entire proprietary rights. The task of KAERI is to develop the physical models and correlations which are required to solve the field equations. It can be divided into four parts; i) flow regime determination, ii) wall heat transfer, iii) wall and interfacial friction, iv) interfacial heat and mass transfer. This paper will describe the process to develop the models for the two-phase flow regime maps in the horizontal and vertical pipes.

2008-05-15

401

Flow Regime Map Models for the Horizontal and Vertical Pipes for the SPACE code  

International Nuclear Information System (INIS)

A safety analysis code, named as SPACE, for a pressurized water reactor is under development to obtain a licensing to be used for the PWR design and to hold entire proprietary rights. The task of KAERI is to develop the physical models and correlations which are required to solve the field equations. It can be divided into four parts; i) flow regime determination, ii) wall heat transfer, iii) wall and interfacial friction, iv) interfacial heat and mass transfer. This paper will describe the process to develop the models for the two-phase flow regime maps in the horizontal and vertical pipes.

2008-05-01

402

Evaluation of tritiated water retention capacity of fusion reactor concrete building  

Energy Technology Data Exchange (ETDEWEB)

In this paper the diffusion of tritiated water vapor into concrete walls is studied to evaluate tritiated water retention capacity of a fusion reactor concrete building. Using a model of the tritiated water diffusion determined form experimental results, depth profiles of tritiated water in concrete are calculated in the case of being exposed to air containing tritiated water vapor during the normal operational condition of a fusion reactor. A 0.5-m-thick concrete is sufficient for reactor hall walls from a viewpoint of the tritium containment.

1992-03-01

403

Evaluation of tritiated water retention capacity of fusion reactor concrete building  

International Nuclear Information System (INIS)

In this paper the diffusion of tritiated water vapor into concrete walls is studied to evaluate tritiated water retention capacity of a fusion reactor concrete building. Using a model of the tritiated water diffusion determined form experimental results, depth profiles of tritiated water in concrete are calculated in the case of being exposed to air containing tritiated water vapor during the normal operational condition of a fusion reactor. A 0.5-m-thick concrete is sufficient for reactor hall walls from a viewpoint of the tritium containment.

404

Domain wall pining in a jointed ferromagnetic nano-wire  

Energy Technology Data Exchange (ETDEWEB)

The magnetoresistance in an FeNi submicron-structure comprising two wires of 80 and 200 nm in width connected in series was measured at 77 K. When the external magnetic field was applied parallel to the wire axis, two switching fields corresponding to the distinct coercive force of the two wires were observed. When the external magnetic field was applied at an angle of {theta}>30 deg. to the wire axis one switching field was observed, indicating simultaneous magnetization reversal in both wires. This indicates that the domain-wall trapping around the joint can be controlled systematically in terms of the direction of the external magnetic field.

2004-05-01

405

Development of thin foil Faraday collector as a lost alpha particle diagnostic for high yield D-T tokamak fusion plasmas  

Energy Technology Data Exchange (ETDEWEB)

Alpha particle confinement is necessary for ignition of a D-T tokamak fusion plasma and for first wall protection. Due to high radiation backgrounds and temperatures, scintillators and semiconductor detectors may not be used to study alpha particles which are lost to the first wall during the D-T programs on JET and ITER. An alternative method of charged particle spectrometry capable of operation in these harsh environments, is proposed: it consists of thin foils of electrically isolated conductors with the flux of alpha particles determined by the positive current flowing from the foils. 2 refs., 3 figs.

1994-07-01

406

Development of electro-optical instrumentation for annular two-phase flow studies  

International Nuclear Information System (INIS)

The development of new electro-optical instrumentation for studying the annular dispersed two-phase flow regime is described. The system measures the thickness of the water film and droplet size and velocity distributions which would be encountered in such a flow regime. The water film thickness is measured by an improved capacitance method with a short time constant using newly developed sensor electrodes. The electrodes are made flush with the inner wall of a cylindrical tube and do not disturb the flow. In the test equipment, steady, laminar flow of water along the inner wall of the tube is controlled by appropriate valves and a porous jacket while droplets are introduced by means of a special spray nozzle.

1981-01-01

407

Anaerobic fermenter-decanter for the purification of residual water from sugar refineries, with recovery of combustible methane  

Energy Technology Data Exchange (ETDEWEB)

An anaerobic fermenter-decanter for the purification of residual water from the sugar industry, with recovery of methane, consists of a tank with inclined walls, with a central agitator on a vertical shaft. A flexible cover anchored by its periphery to the walls of the tank and totally submerged forms a collecting pocket for the fermentation gases. The water to be purified is introduced, after being heated to about 35, towards the bottom of the tank near the agitator. A metal collecting bell with submerged edges and with the shaft of the agitator passing axially through it is connected by its edges to a central opening of the cover. The purification yields may exceed 90%.

1981-10-06

408

X-Ray Phase Imaging for Breast Cancer Detection  

Science.gov (United States)

... Accession Number : ADA535309. Title : X-Ray Phase Imaging for Breast Cancer Detection. Descriptive Note : Annual rept. 1 Sep 2009-31 Aug 2010 ...

2010-09-01

409

Volume 2- Technical Approach - IMAGE Science Center - NASA  

Science.gov (United States)

Power system analysis shows the output from the solar arrays varies as a function .... Each array corresponds to a raw image browse product, which is generated by .... low outgassing, ability to withstand long-term exposure to the space ...

410

Verification of MLC based real-time tumor tracking using an electronic portal imaging device  

UK PubMed Central (United Kingdom)

Purpose: The authors have developed a novel technique using an electronic portal imaging device (EPID) to verify the geometrical accuracy of delivery of dose-rate-regulated tracking (DRRT)....Full Text Available

2010-06-01

411

Technical note: A physical phantom for assessment of accuracy of deformable alignment algorithms  

International Nuclear Information System (INIS)

The purpose of this study was to investigate the feasibility of a simple deformable phantom as a QA tool for testing and validation of deformable image registration algorithms. A diagnostic thoracic imaging phantom with a deformable foam insert was used in this study. Small plastic markers were distributed through the foam to create a lattice with a measurable deformation as the ground truth data for all comparisons. The foam was compressed in the superior-inferior direction using a one-dimensional drive stage pushing a flat 'diaphragm' to create deformations similar to those from inhale and exhale states. Images were acquired at different compressions of the foam and the location of every marker was manually identified on each image volume to establish a known deformation field with a known accuracy. The markers were removed digitally from corresponding images prior to ...

2007-07-01

412

TLD assessment of mouse dosimetry during microCT imaging  

UK PubMed Central (United Kingdom)

Advances in laboratory animal imaging have provided new resources for noninvasive biomedical research. Among these technologies is microcomputed tomography (microCT) which is widely used to obtain high...Full Text Available

2008-09-01

413

Subject-specific, multiscale simulation of electrophysiology: a software pipeline for image-based models and application examples  

UK PubMed Central (United Kingdom)

Many simulation studies in biomedicine are based on a similar sequence of processing steps, starting from images and running through geometric model generation, assignment of tissue properties, numerical...Full Text Available

2009-06-13

414

Study of Stent Deployment Mechanics Using a High-Resolution X-ray Imaging Detector  

UK PubMed Central (United Kingdom)

To treat or prevent some of the 795,000 annual strokes in the U.S., self-expanding endo-vascular stents deployed under fluoroscopic image guidance are often used. Neuro-interventionalists need...Full Text Available

2011-03-01

415

Single exposure energy subtraction chest radiography in the diagnosis of pulmonary cancer  

Energy Technology Data Exchange (ETDEWEB)

A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is ...

1987-03-01

416

Single exposure energy subtraction chest radiography in the diagnosis of pulmonary cancer  

International Nuclear Information System (INIS)

A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is ...

1987-01-01

417

Simple device for scanning image  

CERN Document Server

The simple device for scanning image is described. It has much in common with usual TV camera, with an electron beam replaced by an optical one. After the general description of the device, we present a simple experimental illustration.

2002-01-01

418

Signal and imaging sciences workshop proceedings  

Energy Technology Data Exchange (ETDEWEB)

Papers are presented in the areas of: Medical Technologies; Non-Destructive Evaluation; Applications of Signal/Image Processing; Laser Guide Star and Adaptive Optics; Computational Electromagnetic, Acoustics and Optics; Micro-Impulse Radar Processing; Optical Applications; TANGO Space Shuttle.

1997-11-01

419

SEGMENTING CT PROSTATE IMAGES USING POPULATION AND PATIENT-SPECIFIC STATISTICS FOR RADIOTHERAPY  

UK PubMed Central (United Kingdom)

This paper presents a new deformable model using both population and patient-specific statistics to segment the prostate from CT images. There are two novelties in the proposed method. First,...Full Text Available

2009-08-07

420

Romantic and Sexual Relationships, Body Image, and Fertility in Adolescent and Young Adult Testicular Cancer Survivors: A Review of the Literature  

UK PubMed Central (United Kingdom)

This review presents a summary of existing knowledge regarding the impact of testicular cancer along four broad domains, including romantic and sexual relationships, body image, and fertility....Full Text Available

2010-08-01

421

Retinal Fundus Image Registration via Vascular Structure Graph Matching  

UK PubMed Central (United Kingdom)

Motivated by the observation that a retinal fundus image may contain some unique geometric structures within its vascular trees which can be utilized for feature matching, in this paper, we proposed...Full Text Available

2010-01-01

422

Real-Time Assessment of Cardiac Perfusion, Coronary Angiography, and Acute Intravascular Thrombi Using Dual-Channel Near-Infrared Fluorescence Imaging  

UK PubMed Central (United Kingdom)

ObjectivesWe have developed an image-guided surgery system based on invisible near-infrared (NIR) fluorescent light. Presently, the only clinically-available NIR...Full Text Available

2009-07-01

423

Radio frequency noise from an MLC: a feasibility study of the use of an MLC for linac-MR systems  

UK PubMed Central (United Kingdom)

Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a...Full Text Available

2010-02-21

424

On the sensitivity of IMRT dose optimization to the mathematical form of a biological imaging-based prescription function  

UK PubMed Central (United Kingdom)

Voxel-based prescriptions of deliberately non-uniform dose distributions based on molecular imaging, so-called dose painting or theragnostic radiation therapy, require specification of a transformation...Full Text Available

2009-03-21

425

Noise Characterization of Polycrystalline Silicon Thin Film Transistors for X-ray Imagers Based on Active Pixel Architectures  

UK PubMed Central (United Kingdom)

An examination of the noise of polycrystalline silicon thin film transistors, in the context of flat panel x-ray imager development, is reported. The study was conducted in the spirit of exploring...Full Text Available

2008-01-01

426

New real-time MR image-guided surgical robotic system for minimally invasive precision surgery  

Energy Technology Data Exchange (ETDEWEB)

To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe ...

2008-04-15

427

Multiscale registration of planning CT and daily cone beam CT images for adaptive radiation therapy  

UK PubMed Central (United Kingdom)

Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available

2009-01-01

428

Multi-focal optical-resolution photoacoustic microscopy in vivo  

UK PubMed Central (United Kingdom)

Although ultrasound arrays were exploited in photoacoustic imaging to improve imaging speed, ultrasound-array-based optical-resolution photoacoustic microscopy (OR-PAM) has never been achieved...Full Text Available

2011-04-01

429

Monitoring of NK-Cell Immunotherapy using non-invasive Imaging Modalities  

UK PubMed Central (United Kingdom)

Cancer immunotherapies can be guided by cellular imaging techniques, which can identify the presence or absence of immune-cell accumulation in the tumor tissue in-vivo and in real time. This...Full Text Available

2010-08-01

430

Measurement of the quadriceps femoris muscle using magnetic resonance and ultrasound imaging.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available

1997-03-01

431

JAtlasView: a Java atlas-viewer for browsing biomedical 3D images and atlases  

UK PubMed Central (United Kingdom)

BackgroundMany three-dimensional (3D) images are routinely collected in biomedical research and a number of digital atlases with associated anatomical and other information have...Full Text Available

432

In vivo imaging of neutrotransmitter functions in brain, heart and tumors  

Energy Technology Data Exchange (ETDEWEB)

This volume contains the proceedings of a symposium entitled In Vivo Imaging of Neurotransmitter Function in Brain, Heart, and Tumors'' held August 24--25, 1990 in Montreal Canada. The six individual papers contained herein are separately abstracted and indexed for the database.

1991-01-01

433

Human Lymphatic Architecture and Dynamic Transport Imaged Using Near-infrared Fluorescence12  

UK PubMed Central (United Kingdom)

BACKGROUND: Although the importance of lymphatic function is well recognized, the lack of real-time imaging modalities limits our understanding of its role in many diseases. In a phase...Full Text Available

434

High Contrast Near-infrared Polarized Reflectance Images of Demineralization on Tooth Buccal and Occlusal Surfaces at ?=1310-nm  

UK PubMed Central (United Kingdom)

Background and Objectives:Sound enamel manifests peak transparency in the near-IR (NIR) at 1310-nm, therefore the near-IR is ideally suited for high contrast imaging...Full Text Available

2009-03-01

435

Exploration of exposure dose optimization for pelvic examination in direct digital radiography with a phantom  

International Nuclear Information System (INIS)

Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly different. Conclusion: The ...

2005-10-01

436

Evaluation of Tumor Micro-Environment in an Animal Model using a Nanoparticle Contrast Agent in Computed Tomography Imaging  

UK PubMed Central (United Kingdom)

RATIONALE AND OBJECTIVESNon-invasive longitudinal imaging of tumor vasculature could provide new insights into the development of solid tumors, facilitating efficient...Full Text Available

2011-01-01

437

Early detection of bone metastases of Ewing's sarcoma by magnetic resonance imaging  

International Nuclear Information System (INIS)

Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).

438

Early Detection of Bronchial Lesions Using Lung Imaging Fluorescence Endoscope  

UK PubMed Central (United Kingdom)

The performance of the Lung Imaging Fluorescence Endoscope (LIFE) system was compared with conventional bronchoscopy in 158 patients: 68 patients with invasive cancer, 42 patients with abnormal sputum...Full Text Available

1999-01-01

439

Dual-channel imaging system for singlet oxygen and photosensitizer for PDT  

UK PubMed Central (United Kingdom)

A two-channel optical system has been developed to provide spatially resolved simultaneous imaging of singlet molecular oxygen (1O2) phosphorescence and photosensitizer (PS) fluorescence...Full Text Available

440

Doppler imaging using spectrally-encoded endoscopy  

UK PubMed Central (United Kingdom)

The capability to image tissue motion such as blood flow through an endoscope could have many applications in medicine. Spectrally encoded endoscopy (SEE) is a recently introduced technique...Full Text Available

2008-09-15

441

Digital image precessing for neutron television fluoroscopic system and its application to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the ...

1984-09-01

442

Digital image precessing for neutron television fluoroscopic system and its application to neutron computed tomography  

International Nuclear Information System (INIS)

The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the ...

1984-01-01

443

Design and Implementation of an Open Source Indexing Solution for a Large Set of Radiological Reports and Images  

UK PubMed Central (United Kingdom)

This paper hopes to share the insights we experienced during designing, building, and running an indexing solution for a large set of radiological reports and images in a production environment for...Full Text Available

2007-11-01

444

Correspondence of Ultrasound Elasticity Imaging to Direct Mechanical Measurement in Aging DVT in Rats  

UK PubMed Central (United Kingdom)

Previous ultrasound elasticity imaging experiments supported a generally accepted concept that the hardness of deep venous thrombi increases with thrombus aging. Results also showed that this...Full Text Available

2005-10-01

445

Closing the loop in cortically-coupled computer vision: a brain-computer interface for searching image databases.  

Science.gov (United States)

We describe a closed-loop brain-computer interface that re-ranks an image database by iterating between user generated 'interest' scores and computer vision generated visual similarity measures. The interest scores are based on decoding the electroencephalographic (EEG) correlates of target detection, attentional shifts and self-monitoring processes, which result from the user paying attention to target images interspersed in rapid serial visual presentation (RSVP) sequences. The highest scored images are passed to a semi-supervised computer vision system that reorganizes the image database accordingly, using a graph-based representation that captures visual similarity between images. The system can either query the user for more information, by adaptively resampling the database to create additional RSVP sequences, or it can converge to a 'done' state. The done state includes a ...

2011-05-12

446

Characteristics of common solid liver lesions and recommendations for diagnostic workup  

UK PubMed Central (United Kingdom)

Due to the widespread clinical use of imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available

2009-07-14

447

Challenges of functional imaging research of pain in children  

UK PubMed Central (United Kingdom)

Functional imaging has revolutionized the neurosciences. In the pain field it has dramatically altered our understanding of how the brain undergoes significant functional, anatomical and chemical changes...Full Text Available

448

Automated 3-D method for the correction of axial artifacts in spectral-domain optical coherence tomography images  

UK PubMed Central (United Kingdom)

The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y...Full Text Available

449

Antisense imaging of gene expression in the brain in vivo  

UK PubMed Central (United Kingdom)

Antisense radiopharmaceuticals could be used to image gene expression in the brain in vivo, should these polar molecules be made transportable through the blood–brain barrier....Full Text Available

2000-12-19

450

A high-speed network for cardiac image review.  

UK PubMed Central (United Kingdom)

A high-speed fiber-based network for the transmission and display of digitized full-motion cardiac images has been developed. Based on Asynchronous Transfer Mode (ATM), the network is scaleable, meaning...Full Text Available

1994-01-01

451

A comparison with result of normalized image to different template image on statistical parametric mapping of ADHD children patients  

Energy Technology Data Exchange (ETDEWEB)

We studied 64 ADHD children patients group (4 {approx} 15 ys, mean age: 8 {+-} 2.6 ys. M/F: 52/12) and 12 normal group (6 {approx} 7 ys, mean age: 9.4 {+-} 3.4 ys, M/F: 8/4) of the brain had been used to analysis of blood flow between normal and ADHD group. For analysis of Children ADHD, we used 12 children's mean brain images and made Template image of SPM99 program. In crease of blood flow (P-value 0.05), the result of normalized images to Template image to offer from SPM99 program, showed significant cluster in inter-Hemispheric and occipital Lobe, in the case of normalized images to children template image, showed inter-hemispheric and parietal lobe.

2003-06-15

452

A Software System for Data Analysis in Automated DNA?Sequencing  

UK PubMed Central (United Kingdom)

Software for gel image analysis and base-calling in fluorescence-based sequencing consisting of two primary programs, BaseFinder and GelImager, is described. BaseFinder is a framework for trace processing,...Full Text Available

1998-06-01

453

A Comparison of intra-oral digital imaging modalities: Charged Couple Device versus Storage Phosphor Plate  

UK PubMed Central (United Kingdom)

BackgroundThis in vitro study was conducted to compare the accuracy of two digital image receptors in identifying the location of tip of a fine endodontic file and radiographic apex...Full Text Available

2010-11-01

454

Fracture inspection by BHTV logging through a vinyl chloride tube; Enbi pipe ga sonyusareta kosei deno BHTV ni yoru kiretsu chosa  

Energy Technology Data Exchange (ETDEWEB)

A borehole televiewer (BHTV) logging was conducted to investigate cracks in bored wells. The logging process shoots ultrasonic waves onto bore walls and utilizes reflection waves from the bore walls. If the bores are filled with muddy water, or the ultrasonic waves can pass through even if vinyl chloride tubes have been inserted after excavation, the state of the bore walls can be investigated in principle. Conventional optical scanners are, however, incapable of making this investigation. The BHTV logging can be used for identifying lithofacies from reflection intensities from bore walls (it depends on sound impedance of rocks), not to speak of finding cracks. As a result of making logging upon setting time windows from 105 to 145 {mu} sec in a bored well inserted with a vinyl chloride tube, cracks in the bore wall were identified clearly through the vinyl chloride tube. If the ...

1997-05-27

455

Formation of organic thin film by hot wall vapor deposition. Hot wall jochakuho ni yoru yuki usumaku no keisei  

Energy Technology Data Exchange (ETDEWEB)

The process operation of the hot wall vapor deposition method, formation of dry organic thin film and the control of molecular arrangement were described. This equipment included a substrate on the upper end of the hot wall tube and the vapor source at the lower end. The remarkable features are the hot wall tube which plays the role to hold vaporizing molecules to the high temperature and to transport molecules, and the flip flop mechanism which gives some idle period for the molecular vaporization by shutter closing. Several experiments were carried out by using stearic acid and by changing the distance S from the upper end of hot wall quartz tube to the substrate, the furnace temperature T{sub f} and the substrate temperature T{sub s}. When T{sub f} is equal to or less than the melting point of stearic acid, molectles are preferentialy made to vertical arrangement. In the case of T{sub f} more than ...

1991-12-01

456

Effect of electron irradiation on domain wall pinning defects in 50-50 NiFe  

International Nuclear Information System (INIS)

A magnetic measuring technique, which sorts out defects according to a distribution function n, was used to study the influence of electron irradiation on 50-50 NiFe. The distribution function is determined in terms of the maximum force f/subm/ that a defect can exert on a forward moving domain wall, or equivalently, the range z_0, which is the distance the mean position of the wall may move past the defect before the wall snaps free from the pinning action of the defect. The range and maximum force are related by a spring constant k, viz., f/subm/=kz_0. The quantity n (z_0) dz_0 gives the number of defects per unit volume having a range between z_0 and z_0+dz_0. Distribution functions were determined before and after electron irradiation. The irradiation was for 100 min with 18-MeV electrons with a dose of 1.1times10"1"7 e/cm"2. Following irradiation, there was a substantial decrease in the number of short-range defects ...

457

Comparison of sclerosing cholangitis with autoimmune pancreatitis and infiltrative extrahepatic cholangiocarcinoma. Multidetector-row computed tomography findings  

International Nuclear Information System (INIS)

The aim of this study was to compare multidetector-row computed tomography (MDCT) findings between cases of sclerosing cholangitis with autoimmune pancreatitis (SC-AIP) and infiltrative extrahepatic cholangiocarcinoma (IEC). We retrospectively assessed MDCT findings from 16 IEC cases and 13 SC-AIP cases. MDCT findings were analyzed with regard to location, length, wall thickness, contour, stricture wall enhancement pattern, proximal duct diameter, and the presence of diffuse concentric thickening in the proximal duct and gallbladder wall thickness. Stricture length, stricture wall thickness, and proximal duct diameter were significantly smaller for SC-AIP than for IEC: 19.3#+-#8.7 vs. 31.8#+-#12.0 mm (P=0.004), 2.1#+-#1.3 vs. 4.1#+-#1.3 mm (P<0.001), and 9.2#+-#3.9 vs. 13.3#+-#5.0 mm (P=0.012), respectively. SC-AIP was correlated with stricture location in both the intrapancreatic and hilar hepatic ...

2010-04-01

458

metadata, images and captions. - The Gateway to Astronaut ...  

Science.gov (United States)

... the Zaire is not an efficient transportation link because of many rapids and falls to negotiate between Kinshasa and the port city of Matadi. ...

459

Visible Earth: Food Additives  

Science.gov (United States)

Feb 25, 2008 ... NASA's Visible Earth catalog of NASA images and animations of our home planet.

460

Using Acoustic Tomography to Monitor Deep Ocean Currents ...  

Science.gov (United States)

... 2009. Copyright belongs to the Marine Technology Society., The original document contains color images. 14. ABSTRACT ...

2010-06-01

461

Tolerance limits of X-ray image intensity  

International Nuclear Information System (INIS)

Evaluation of the tolerance limits of X-ray image density accepted by the radiologist shows that for different kinds of examinations, deviations of more than 50% from optimal density lead to images which cannot be used diagnostically. Within this range diagnostic accuracy shows a distinct maximum and diminishes to the limits by 20%. These figures are related to differences in the intensifying factor of screens, sensitivity of films, sensitometric parameters of film processing as well as the doses employed with automatic exposure control devices, measured in clinical conditions. Maximum permissible tolerance limits of the whole imaging system and of its constituents are discussed using the Gaussian law of error addition. (author).

462

Three-dimensional image display of brain tumor utilizing a modified voxel method  

Energy Technology Data Exchange (ETDEWEB)

The patch and voxel methods are representative examples of the ways in which multi-slice images may be displayed three-dimensionally by means of computer-graphics. Each of them have advantages and disadvantages and they are mutually complementary. We have developed algorithms for a modified voxel method which incorporates the advantages of the patch methods. We have applied this to the three-dimensional image display of brain tumor with excellent results. The three-dimensional reconstructions used for clinical application in this study were derived from X-ray CT images.

1988-08-01

465

Stereotactic Radiation Therapy for Brain Tumors  

Medline Plus

... acquired, which we then volumetrically fuse with the 3D image set from the MR. And by doing ...

467

Radioiodine benzodiazepines as brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a radioiodinated benzodiazepine derivative. It comprises a lower alkyl group with 1-4 C-atoms and a radioactive iodine.

1992-03-17

468

Radioiodine benzodiazepines as brain imaging agents  

International Nuclear Information System (INIS)

This patent describes a radioiodinated benzodiazepine derivative. It comprises a lower alkyl group with 1-4 C-atoms and a radioactive iodine.

1990-06-25

469

RAPID DAMAGE ASSESSMENT FROM HIGH RESOLUTION IMAGERY  

Energy Technology Data Exchange (ETDEWEB)

Disaster impact modeling and analysis uses huge volumes of image data that are produced immediately following a natural or an anthropogenic disaster event. Rapid damage assessment is the key to time critical decision support in disaster management to better utilize available response resources and accelerate recovery and relief efforts. But exploiting huge volumes of high resolution image data for identifying damaged areas with robust consistency in near real time is a challenging task. In this paper, we present an automated image analysis technique to identify areas of structural damage from high resolution optical satellite data using features based on image content.

2008-07-01

470

Prospects for lithium imaging using annular bright field scanning transmission electron microscopy: A theoretical study  

British Library Electronic Table of Contents (United Kingdom)

There is strong interest in lithium imaging, particularly because of its significance in battery materials. However, light atoms only scatter electrons weakly and atomic resolution direct imaging of lithium has proven difficult. This paper explores theoretically the conditions under which lithium columns can be expected to be directly visible using annular bright field scanning transmission electron microscopy. A detailed discussion is given of the controllable parameters and the conditions most favourable for lithium imaging.

2011-01-01

473

Phase imaging using laser-produced X-ray sources  

International Nuclear Information System (INIS)

A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. The authors established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging

2000-08-01

474

Particle-Sizing System for Scanning Electron Microscope ...  

Science.gov (United States)

... THESIS PARTICLE-SIZING SYSTEM FOR SCANNING ELECTRON MICROSCOPE IMAGES OF SOLID-PROPELLANT COMBUSTION EXHAUST ...

1991-03-01

475

Non-traumatic thoracic emergencies: imaging and treatment of thoracic fluid collections (including pneumothorax)  

International Nuclear Information System (INIS)

Cross-sectional imaging has revolutionised the radiological diagnosis of pleural collections. Not only can the precise location and volume of a pleural effusion be established, but also features specific for the aetiology of the effusion can be demonstrated. Increasingly, radiologists are called upon to perform image-guided biopsies, aspirations and small bore chest drain placement, all of which have been shown to be safe and efficacious. Pneumothoraces occurring due to acute trauma and in an intensive care setting can also benefit from radiological input, both in terms of diagnosis and image-guided treatment. (orig.)

2002-08-01

476

Monitoring the movement of water influx subsidence in coal district by remote sensing - examples from Huainan coal district  

Energy Technology Data Exchange (ETDEWEB)

Multitemporal TM images are used to collect information about the extension and variation of water influx subsidence in coal district in order to provide a reference for the harnessing and utilization of water influx subsidence. The multitemporal TM images are used as a blended data group for the analysis of the principal components to reflect the expanding water influx subsidence in the past years. Because of the differences in the environment and imaging condition, 'unitary' order is used to enhance the 'coherence' and 'comparability' of the original TM images. 5 refs., 4 figs., 2 tabs.

2002-08-01

477

MER-DIMES : a planetary landing application of computer vision  

Science.gov (United States)

During the Mars Exploration Rovers (MER) landings, the Descent Image Motion Estimation System

2005-01-01

480

Incidental discovery of asplenia syndrome, with situs inversus and a normal heart by radionuclide biliary imaging. A case report  

International Nuclear Information System (INIS)

/sup 99m/Tc biliary imaging was performed on a 34-year-old woman who was being investigated for suspected cholelithiasis. A left-sided liver was detected. On subsequent radionuclide imaging, partial visceral situs inversus and asplenia were demonstrated. Extensive roentgenographic investigation, ECG, echocardiogram, and laparotomy confirmed the radionuclide findings. Asplenia syndrome may exist without cardiovascular abnormalities and thus be undiscovered. Radionuclide imaging is important in the diagnosis of this syndrome.

481

Improved quadrant anode image sensor with microchannel plates  

Energy Technology Data Exchange (ETDEWEB)

We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes.

1987-11-15

482

Imaging characterization of carbon nanotube tips modified using a focused ion beam  

International Nuclear Information System (INIS)

A carbon nanotube (CNT) tip, which assembled on the sharp end of a Si tip by dielectrophoresis, was structurally modified using focused ion beam (FIB). We described the imaging characterization of the FIB-modified CNT tip in noncontact AFM mode in terms of wear, deep trench accessibility, and imaging resolution. Compared to a conventional Si tip, the FIB-modified CNT tip was superior, especially for prolonged scanning over 10 h. We conclude that modified CNT tips have the potential to obtain high-quality images of nanoscale structures.

2007-06-15

483

Image Descriptors for Displays  

Science.gov (United States)

... 44 2. Luminance Power Spectral Density Measurements ..... 44 ... 50 4. Chrominance Power Spectral Density Measurements ..... 53 ...

1977-02-01

484

Iao: The New Adaptive Optics Visible Imaging and ...  

Science.gov (United States)

... is the sensor that converts incoming photons into a ... with CCD foundries to acquire such a sensor. ... 2007, Journal of Spacecraft and Rockets, 44, 910 ...

2008-09-01

485

Growth, Characterization and Device Development in ...  

Science.gov (United States)

... eV. In some instances the spontaneous radiation from a free electron laser system was employed to obtain images. The ...

1998-03-01

487

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

488

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

489

Development of ARIES Baker-Nunn camera to a wide-field Imaging Telescope with CCD  

CERN Document Server

ARIES Baker-Nunn Schmidt telescope project is converting a Baker-Nunn satellite tracking camera for Astronomical research. Original Baker-Nunn camera produces an extremely large (5X30 degree) curved focal plane at the prime focus for photographic imaging. We present here the re-designing of the camera produces a wide (4 X 4 degree) flat field of view for CCD imaging observations, which have many scientific potentials in Astronomy. Imaging performance of the CCD camera is also estimated.

2009-01-01

490

Detection and Diagnosis of Oral Neoplasia with an Optical ...  

Science.gov (United States)

... Thus, 0CM provides the potential to image epithelial tissue with the subcellular resolution needed to assess the pathologic state of tissue. ...

491

DVRPC 2010 Digital Orthoimagery - Mr.SID County Mosaics  

Science.gov (United States)

... image overlap between adjacent tiles. Orthoimagery processed by BAE Systems....

492

Computer vision approaches to medical image analysis. Revised papers  

Energy Technology Data Exchange (ETDEWEB)

This book constitutes the thoroughly refereed post proceedings of the international workshop Computer Vision Approaches to Medical Image Analysis, CVAMIA 2006, held in Graz, Austria in May 2006 as a satellite event of the 9th European Conference on Computer Vision, EECV 2006. The 10 revised full papers and 11 revised poster papers presented together with 1 invited talk were carefully reviewed and selected from 38 submissions. The papers are organized in topical sections on clinical applications, image registration, image segmentation and analysis, and the poster session. (orig.)

2006-07-01

493

Cerebral angiography using Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Eighty-seven subtraction images of FCR were compared with subtraction images of conventional angiography. Although FCR images with reduced exposure dose (25 % of regular dose) and with diluted contrast material (150 mgI/ml, 50 % of usual concentration) were slightly inferior to the images of conventional angiography, most clinically important vessels were adequately visualized. As FCR has wider dynamic range and higher contrast resolution than conventional angiography, FCR may take over conventional angiography. (author).

1985-01-01

494

Burned Timber Canyon  

Science.gov (United States)

The Digital Raster Graphic (DRG) is a raster image of a scanned USGS topographic map including the collar information, georeferenced to the UTM grid....

495

An improved quadrant anode image sensor with microchannel plates  

International Nuclear Information System (INIS)

We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes. (orig.).

1987-11-01

496

An improved quadrant anode image sensor with microchannel plates  

Science.gov (United States)

We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes.

1987-11-01

498

A Computer Vision System forAnalyzing Images of Rough Hardwood Lumber  

Science.gov (United States)

... In this paper research aimed at creating a computer vision system to power such an optimal edging and ... ...