WorldWideScience
1

Scintigraphic imaging of dementia: Technical acquisition  

International Nuclear Information System (INIS)

Scintigraphic imaging of dementia relies today essentially on the study of brain Single Photo Emission Computed Tomography (SPECT) perfusion, after intravenous injection of 99mTc radio-pharmaceutic. This paper is based on the guidelines published in October 2001 by the European Association of Nuclear Medicine (http://eanm.org/). (author)

2007-06-01

2

The role of Multidetector CT in the evaluation of the left atrium and pulmonary veins anatomy before and after radio-frequency catheter ablation for atrial fibrillation. Preliminary results and work in progress.Technical note  

International Nuclear Information System (INIS)

Radio-frequency catheter ablation (RFCA) of the distal pulmonary veins is increasingly being used to treat recurrent or refractory atrial fibrillation that doesn't respond to pharmacologic therapy or cardioversion. Successful RFCA of atrial al fibrillation depends on the pre-procedural understanding of the complex anatomy of the distal pulmonary veins and the left atrium. Aim of this parer is to describe the technical main features that characterise the multidetector helical computed tomography in the evaluation of this anatomic region before and after RFCA procedure. The 3D post-processing techniques useful for pre-RFCA planning are straightforward.

3

Toward the Creation of the World's Smallest Radio  

Science.gov (United States)

... 4. TITLE AND SUBTITLE Toward the Creation of the World's Smallest Radio 5a. ... Toward the Creation of the World's Smallest Radio ...

2011-05-15

4

Fast Beam Intensity Measurements for the LHC  

CERN Document Server

Particle accelerators are constructed and operated for a wide variety of applications. In particle physics - the branch of physics that studies the elementary constituents of matter and forces between them - high energy accelerators are used to look deep into the structure of matter. Medical particle accelerators are used for example in medicine to treat tumours [31], in imaging techniques such as Positron Emission Tomography (PET) [24], or for the radio-isotopes production. They also serve in many other industrial branches, e.g. geology, radiocarbon dating [39], molecular complex spectroscopy, lithography, food preservation etc. The eld of accelerator technology draws knowledge and expertise from a wide range of scientic disciplines and uses the latest technical knowledge. The incomplete list of covered disciplines includes mathematics, physics, electronics, computing, electromagnetic eld technology, microwave technology, cryogenics, vacuum ...

2010-01-01

6

On The Parent Population of Radio Galaxies and the FR I--II Dichotomy  

CERN Document Server

The possibility of radio galaxies being random sample of otherwise normal elliptical galaxies is tested. Starting with the observed optical luminosity functions for elliptical galaxies, it is shown that the probability of an elliptical forming a radio source is a continuous, increasing function of optical luminosity, precisely proportional to square of the optical luminosity of the galaxy. Once the probability function is fixed, the luminosity function of normal elliptical galaxies is used as input for Monte Carlo simulations that reproduce the distribution of radio galaxies in the radio-optical luminosity plane. Our results show that radio galaxies are luminosity biased, but otherwise random sample of elliptical galaxies. This unified view of radio and non-radio ellipticals also explains the well known difference of 0.5 mag in average ...

2001-01-01

7

Simulation and Observation of Acoustic-Gravity Waves in the Ionosphere  

Science.gov (United States)

Atmospheric and ionospheric perturbations associated with the acoustic-gravity waves (AGW) with typical frequencies of a few hertz -millihertz are considered. These events may be caused by the influence from space and atmosphere as well as by oscillations of the Earth surface and other near-surface phenomena. The surface sources include long-period oscillations of the Earth's surface, earthquakes, explosions, thermal heating, seisches and tsunami waves. The wavelike phenomena manifest themself as travelling disturbances of air (in the atmosphere) and of electron density (in the ionosphere). Travelling ionospheric disturbances (TIDs) are well detected by radio physical methods. AGW generation by near-surface sources is modeled by the numerical solution of the equation of geophysical fluid dynamics for different sources in two-dimensional non-linear dissipative compressible atmosphere. The numerical calculations are based on the FCT (Flux Corrected Transport) ...

2010-01-01

8

Extended radio emission in MOJAVE Blazars: Challenges to Unification  

CERN Document Server

We present the results of a study on the 1.4 GHz kpc-scale radio emission in the complete flux density limited MOJAVE sample, comprising 135 radio-loud AGNs. While extended emission is detected in the majority of the sources, about 7% of the sources exhibit only radio core emission. Many BL Lacs exhibit extended radio power and kpc-scale morphology typical of powerful FRII jets, while a substantial number of quasars possess radio powers intermediate between FRIs and FRIIs. This poses challenges to the simple radio-loud unified scheme, which links BL Lacs to FRIs and quasars to FRIIs. We find a significant correlation between extended radio emission and pc-scale jet speeds: the more radio powerful sources possess faster jets. This indicates that the 1.4 GHz (or low frequency) radio emission is indeed ...

2010-01-01

9

Survey of Cognitive Radio Techniques in Wireless Network  

CERN Document Server

In this report, I surveyed the cognitive radio technique in wireless networks. Researched several kinds of cognitive techniques about their advantages and disadvantages.

2011-01-01

10

Searches for Fast Radio Transients  

CERN Document Server

We discuss optimal detection of fast radio transients from astrophysical objects while taking into account the effects of propagation through intervening ionized media, including dispersion, scattering and scintillation.Our analysis applies to the giant-pulse phenomenon exhibited by some pulsars, for which we show examples, and to radio pulses from other astrophysical sources, such as prompt radio emission from gamma-ray burst sources and modulated signals from extra-terrestrial civilizations.

2003-01-01

12

On The Parent Population of Radio Galaxies and the FRI - FRII Dichotomy  

CERN Document Server

We test the hypothesis that radio galaxies are a random subset of otherwise normal elliptical galaxies. Starting with the observed optical luminosity functions for elliptical galaxies, we show that the probability of an elliptical forming a radio source is a continuous, increasing function of optical luminosity, proportional to L squared. With this probability function and the luminosity function of normal elliptical galaxies as input to Monte Carlo simulations, we reproduce the observed distribution of radio galaxies in the radio-optical luminosity plane. Our results show that radio galaxies are a luminosity-biased but otherwise random sample of elliptical galaxies. This unified view of radio-loud and radio-quiet ellipticals also explains the well known difference of ~0.5 mag in average optical luminosity between FRI and FRII ...

2001-01-01

13

Osteoporosis and prevention. Assessment of mineral density, geometry and biomechanics of bone by means of peripheral quantitative Computed Tomography (pQCT) in premenopausal women assuming phytoestrogens; Osteoporosi e fitoestrogeni: valutazione della densita' minerale ossea mediante tomografia computerizzata quantitativa periferica nelle donne lattoovovegetariane nella premenopausa  

Energy Technology Data Exchange (ETDEWEB)

Aim of the work was to describe the noninvasive assessment of bone mineral density, geometrical and biochemical properties in premenopausal women with dietary intake of phytoestrogens and comparison of these parameters with those of age-matched female subjects with Mediterranean dietary intake lacking in these substances. Volumetric cortical, trabecular and total mineral density and bone geometrical properties were evaluated with peripheral quantitative computed tomography (pQCT) at the distal radius of the non dominant forearm. pQCT showed higher bone mineral density (total and trabecular) and SSI values in premenopausal with dietary intake of phytoestrogens. Despite the lack of statistical significance, these preliminary results, should further support the few literature findings about the potential role of phytoestrogens consumption in preventing trabecular bone loss. However, further studies are warranted to evaluate definitively postmenopausal osteoporosis. ...

2000-04-01

14

[Somatic radiation risk in conventional tomography of the skull and thorax].  

Science.gov (United States)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other x-ray examinations, especially computerised tomography. PMID:7134769

1982-10-01

15

Somatic radiation risk in conventional tomography of the skull and thorax  

Energy Technology Data Exchange (ETDEWEB)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography.

1982-10-01

16

Somatic radiation risk in conventional tomography of the skull and thorax  

International Nuclear Information System (INIS)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography. (orig.).

1982-01-01

17

Galaxy Cluster Environments of Radio Sources  

CERN Document Server

Using the Sloan Digital Sky Survey (SDSS) and the FIRST (Faint Images of the Radio Sky at Twenty Centimeters) catalogs, we examined the optical environments around double-lobed radio sources. Previous studies have shown that multi-component radio sources exhibiting some degree of bending between components are likely to be found in galaxy clusters. Often this radio emission is associated with a cD-type galaxy at the center of a cluster. We cross-correlated the SDSS with the FIRST catalog and measured the richness of the cluster environments surrounding both bent and straight multi-component sources. This led to the discovery and classification of a large number of galaxy clusters out to a redshift of z ~ 0.5. We divided our sample into smaller subgroups based on their optical and radio properties. We find that FR I radio sources are more likely to be found in ...

2010-01-01

18

Cold gas & mergers: fundamental difference in HI properties of different types of radio galaxies?  

CERN Document Server

We present results of a study of large-scale neutral hydrogen (HI) gas in nearby radio galaxies. We find that the early-type host galaxies of different types of radio sources (compact, FR-I and FR-II) appear to contain fundamentally different large-scale HI properties: enormous regular rotating disks and rings are present around the host galaxies of a significant fraction of low power compact radio sources, while no large-scale HI is detected in low power, edge-darkened FR-I radio galaxies. Preliminary results of a study of nearby powerful, edge-brightened FR-II radio galaxies show that these systems generally contain significant amounts of large-scale HI, often distributed in tail- or bridge-like structures, indicative of a recent galaxy merger or collision. Our results suggest that different types of radio galaxies may have a different formation history, which ...

2008-01-01

19

Single photon emission tomography of the pituitary: preliminary communication.  

UK PubMed Central (United Kingdom)

A specific application of single photon emission tomography to the relative quantitation of the pituitary region is described together with the results obtained in 19 patients with pituitary adenoma...Full Text Available

1981-09-01

20

Optical Coherence Tomography Findings in Idiopathic Macular Holes  

UK PubMed Central (United Kingdom)

Purpose. To describe the characteristics of idiopathic macular holes (MH) on optical coherence tomography (OCT) and correlate OCT with clinical assessment. Design....Full Text Available

2011-01-01

21

Computed tomography of head in Clinic Pediatrics  

Energy Technology Data Exchange (ETDEWEB)

138 unselected head tomographies of children by computer are reported and analysed. The major aspect stressed by the authors is the excellent precision of this radiological technique.

1982-02-01

22

Psychometric evaluation of a radio electric auricular treatment for stress related disorders: a double-blinded, placebo-controlled controlled pilot study  

UK PubMed Central (United Kingdom)

BackgroundThe aim of this double-blind randomized study is to test the efficacy of a radio electric stimulator device using an auricular reflex therapy protocol for stress-related...Full Text Available

23

Electromagnetic fields, pacemakers and defibrillators; Champs electromagnetiques, cardiostimulateurs et defibrillateurs  

Energy Technology Data Exchange (ETDEWEB)

Presentation of electromagnetic sources constituted by various radio transmitters contributing to different radio communication services in the environment. Results of a measures campaign to assess the electromagnetic field in the close neighbourhood of various stations. Analysis by frequency domains. (author)

2004-07-01

24

STUDY AND MODIFICATION OF CONVECTIVE STORMS  

Science.gov (United States)

... small water or ice particles by impaction ... flight recording; principally the hydrometeor charge unit ... capability of directing aircraft movements by radio ...

1963-06-30

25

Neutrinos from flat-spectrum radio quasars  

Science.gov (United States)

The GRO observation (Hartman et al., 1992) of a very strong flux of gamma rays with an energy index

1992-01-01

26

Chromosomal damage in human lymphocytes from radio-isotope therapy  

International Nuclear Information System (INIS)

(Dec 1973). United Kingdom Stevenson, AC Medical Research Council, Oxford

27

Trial of using computer tomography in the diagnosis of mediastinal diseases in children  

Energy Technology Data Exchange (ETDEWEB)

In 15 children (in age 2 weeks - 15 years) the computer tomography beside radiological examination was done because of mediastinal diseases. In all cases the computer tomography was valuable. In 4 cases obtained results have changed diagnostic conclusions. The examples are described showing the usefulness of the computer tomography as supplementary diagnostic method in mediastinal diseases in children.

1981-01-01

31

Importance of computer tomography in paediatric diagnostics of abdominal and pelvic tumours  

Energy Technology Data Exchange (ETDEWEB)

In a joint study conducted by the University Clinic of Radiology, Graz, and the Medical University Clinic, Innsbruck, the results of computer tomography examinations of the abdomen and pelvis in 23 cases of tumours in children are discussed. In children computer tomography resents special difficulties on account of the very poorly developed fatty layers between the organs and the increased incidence of movement artifacts. The importance of computer tomography for the diagnosis of abdominal and pelvic tumours is discussed.

1980-03-01

32

Demonstration of neutron radiography and computed tomography at the University of Texas thermal neutron imaging facility  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere.

1999-09-01

33

Demonstration of neutron radiography and computed tomography at the University of Texas thermal neutron imaging facility  

International Nuclear Information System (INIS)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere

1999-06-06

34

Heterophyle antibodies causing false positive radio-immunoassay results a case report  

International Nuclear Information System (INIS)

A case report of falsely elevated serum hormone values measured by radio-immunoassay (RIA) is described. The radio-immunoassays concerned have a first antibody raised in rabbits and mostly a separation technique based on a second antibody-solid phase system. The presence of heterophyle (anti-rabbit) antibodies in patients' serum is proved.

35

Fault prediction on high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

The prediction of faults on high voltage transmission lines requires the detection of incipient faults, which is implemented by detection of the radio noise due to contaminated insulators, insulation deterioration, and improver connections. It is shown that the radio noise due to incipient faults is separable and identifiable from normal transmission line radio noise, hence faults can be predicted.

1982-12-01

36

Radio and television interference caused by corona discharges from high-voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmission line voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmission line conductors. Transmission line noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmission lines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, corona radio noise varies significantly with the weather and atmospheric conditions ...

1996-11-01

37

Radio and television interference caused by corona discharges from high-voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmission line voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmission line conductors. Transmission line noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmission lines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, corona radio noise varies significantly with the weather and atmospheric conditions ...

1995-10-01

38

Radio and television interference caused by corona discharges from high-voltage transmission lines  

International Nuclear Information System (INIS)

Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmission line voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmission line conductors. Transmission line noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmission lines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, corona radio noise varies significantly with the weather and atmospheric conditions ...

1996-04-09

39

Fermi pulsar revolution  

CERN Document Server

2009 has been an extraordinary year for gamma-ray pulsar astronomy and 2010 promises to be equally good. Not only have we registered an extraordinary increase in the number of pulsars detected in gamma rays, but we have also witnessed the birth of new sub-families: first of all, the radio-quiet gamma pulsars and later an ever growing number of millisecond pulsars, a real surprise. We started with a sample of 7 gamma-ray emitting neutron stars (6 radio pulsars and Geminga) and now the Fermi-LAT harvest encompasses 24 "Geminga-like" new gamma-ray pulsars, a dozen millisecond pulsars and about thirty radio pulsars. Moreover, radio searches targeted to LAT unidentified sources yielded 18 new radio millisecond pulsars, several of which have been already detected also in gamma rays. Thus, currently the family of gamma-ray emitting neutron stars seems to be evenly divided between classical ...

2010-01-01

40

Using Multidetector Computed Tomography in a Swine Model to Assess the Effects of Sublingual Nitroglycerin and Intravenous Adenosine on Epicardial Coronary Arteries  

UK PubMed Central (United Kingdom)

This study examines the effects of intravenous infusion of adenosine and sublingual nitroglycerin on coronary angiograms obtained by current-generation multidetector computed tomography. We assessed...Full Text Available

2009-12-01

41

Prevalence of Renal Artery and Kidney Abnormalities by Computed Tomography among Healthy Adults  

UK PubMed Central (United Kingdom)

Background and objectives: Management of incidental renal artery and kidney abnormalities in patients undergoing computed tomography scans is a clinical challenge because their frequency in healthy...Full Text Available

2010-03-01

42

Macular and retinal nerve fiber layer thickness in Japanese measured by Stratus optical coherence tomography  

UK PubMed Central (United Kingdom)

The purpose of this study was to determine the thickness of the macula and the retinal nerve fiber layer (RNFL) in Japanese subjects by Stratus optical coherence tomography (OCT), and to compare the...Full Text Available

2007-06-01

43

Is Computerized Tomography Angiographic Surveillance Valuable for Prevention of Tracheoinnominate Artery Fistula, a Life-Threatening Complication after Tracheostomy?  

UK PubMed Central (United Kingdom)

ObjectiveThe aim of this study was to evaluate the utility of volume-rendered helical computerized tomography (CT) angiography focusing tracheostomy tube and innominate artery for...Full Text Available

2011-02-01

44

High-Speed Ultrahigh-Resolution Optical Coherence Tomography Findings in Chronic Solar Retinopathy  

UK PubMed Central (United Kingdom)

PurposeTo describe ocular findings for a 34-year-old man with chronic solar retinopathy using high-speed ultrahigh-resolution (UHR) optical coherence tomography (OCT).Full Text Available

2008-01-01

45

Clinical Assessment of Mirror Artifacts in Spectral-Domain Optical Coherence Tomography  

UK PubMed Central (United Kingdom)

Purpose.To investigate the characteristics of a spectral-domain optical coherence tomography (SD-OCT) image phenomenon known as the mirror artifact, calculate its prevalence, analyze...Full Text Available

2010-07-01

46

Automated 3-D method for the correction of axial artifacts in spectral-domain optical coherence tomography images  

UK PubMed Central (United Kingdom)

The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y...Full Text Available

47

Artery phantoms for intravascular optical coherence tomography: healthy arteries  

UK PubMed Central (United Kingdom)

We present a method to make phantoms of coronary arteries for intravascular optical coherence tomography (IV-OCT). The phantoms provide a calibrated OCT response similar to the layered structure of...Full Text Available

48

A Distinctive Disk-Jet Coupling in the Seyfert-1 AGN NGC 4051  

CERN Document Server

We report on the results of a simultaneous monitoring campaign employing eight Chandra X-ray (0.5-10 keV) and six VLA/EVLA (8.4 GHz) radio observations of NGC 4051 over seven months. Evidence for compact jets is observed in the 8.4 GHz radio band; This builds on mounting evidence that jet production may be prevalent even in radio-quiet Seyferts. Assuming comparatively negligible local diffuse emission in the nucleus, the results also demonstrate an inverse correlation of L_radio proportional to L_X-ray ^(-0.72+/-0.04) . Current research linking the mass of supermassive black holes and stellar-mass black holes in the "low/hard" state to X-ray luminosities and radio luminosities suggest a "fundamental plane of accretion onto black holes" that has a positive correlation of L_radio proportional to L_X-ray^(0.67+/-0.12) . Our simultaneous results differ from this ...

2010-01-01

49

Using Acoustic Tomography to Monitor Deep Ocean Currents ...  

Science.gov (United States)

... 2009. Copyright belongs to the Marine Technology Society., The original document contains color images. 14. ABSTRACT ...

2010-06-01

52

Radiation dose in computerized tomography  

International Nuclear Information System (INIS)

Dosimetric studies in 80 patients examined with the tomographic device 'Somatom' are reported. The gonad doses are compared to those of conventional radiographic techniques.

54

Magnetic resonance imaging in childhood epilepsy  

International Nuclear Information System (INIS)

The suitability of MR imaging versus computerized tomography in observation of brain development disorders in children are compared. 13 refs.

56

Computerized tomography of the adrenal glands in the Cushing Syndrome propaedeutic  

International Nuclear Information System (INIS)

Portuguese (Mar 1983). Brazil Furlanetto, RP Abucham Filho, J. Albertotti,

1982-10-24

57

The different structural scales of the breast and their impact on time-of-flight and diffraction tomography  

Energy Technology Data Exchange (ETDEWEB)

Ultrasound tomography is an attractive imaging method for the detection of breast cancer. The complex anatomy of the breast with its different spatial scales and material property contrasts make accurate reconstructions very challenging. This paper proposes a hybrid approach whereby Travel-of-Flight and Diffraction Tomography are combined together to achieve high-resolution and high-accuracy sound-speed reconstructions. The method is validated with several numerical phantoms.

2010-01-01

58

Computer tomography used in tumour diagnosis in children  

Energy Technology Data Exchange (ETDEWEB)

Computer tomography used in the diagnosis of tumours is described in the light of particularly great diagnostic difficulties in children. Computer tomography was applied in 12 cases. A high diagnostic value of this method was demonstrated, which makes possible a more accurate diagnosis of the position of the tumour, its size, and expanding tendency. The possibility of estimating healthy tissues and organs, and those with pathological changes on the basis of differences in their density with a detection threshold at 0.5% density difference facilitates not infrequently preoperative diagnosis raising the value of the method.

1981-01-01

59

Computer tomographic ventriculography  

Energy Technology Data Exchange (ETDEWEB)

A method for elucidating complex abnormalities of CSF circulation by using a positive contrast medium (metrizamide) and computer tomography is described. The technique for the method, the results and their clinical significance is demonstrated. The value of this method is compared with traditional ventriculography and with computer tomography without the use of contrast medium. It is shown that the technique represents an important extension of the scope of computer tomography.

1982-04-01

60

Terms Beginning With \\  

Wastenet

... Microwaves, radio waves, and low-frequency electromagnetic fields from high-voltage transmission lines . Non-Methane Hydrocarbon (NMHC): The sum of all hydrocarbon air ...

61

Solar-Geophysical Data Number 438, February 1981. Part 1 (prompt reports). Data for January 1981, December 1980 and late data  

Energy Technology Data Exchange (ETDEWEB)

Contents include: index for 1970-1980; January 1981 data -- alert periods, daily solar indices, solar flares, solar radio emission, coronal holes, inferred interplanetary magnetic field polarities, mean solar magnetic field, spacecraft observations, December 1980 data -- daily solar-activity centers, sudden ionospheric disturbances, spacecraft observations, solar radio emission, cosmic rays, geomagnetic indices, radio-propagation indices; late data -- solar radio emission November, December 1980, spacecraft observations November 1980, cosmic rays, Huancayo Oct 1980 -- climax, alert, Deep River Nov 1980.

1981-02-01

62

NRAO: Press Releases  

Science.gov (United States)

Evolution in Space Radio Telescopes Reveal Youngest Stellar Corpse Gas Clouds in Whirlpool Galaxy Yield Important Clues Supporting Theory on Spiral Arms Starbust-driven Winds...

2011-10-09

63

Modeling the AIM-9 Sidewinder Repair Line through Discrete ...  

Science.gov (United States)

... of electronic systems (satellite terminals, radio and ... helps organizations investigate the stochastic nature of ... cycle time, maximum queue lengths, and ...

2009-06-01

64

Hypoxia and Magnetic Therapy for Personnel Radiation Protection  

International Science & Technology Center (ISTC)

Development of Portable Normobaric Hypoxia and Pulsed Magnetic Field Firmware System for Enhancement of Radio- and Non-specific Resistance in Workers of Environmentally Hazardous Industries

65

Deep Space Probe Science Experiment  

Science.gov (United States)

Briefly, 48 MOS microparticle sensors (essentially the same as those flown on .... at the Naval Research Lab to interpret the polarization of the incoming radio .... Adapter Satellite, to be published in Journal of Spacecraft and Rockets, 1994. ...

66

DSN Radio Science ... - InterPlanetary Network (IPN) Progress Report  

Science.gov (United States)

tions, final noise-power spectral density measurements were made. These measurements of the noise-power spectral density were not the desired phase- noise ...

67

Battle Management Command and Control (BMC2) Human ...  

Science.gov (United States)

... For communication systems that employ spatial audio technology to separate intercom and/or radio channels, configurations of the spatial ...

2005-06-01

68

A Network Coding Approach to Loss Tomography  

CERN Document Server

Network tomography aims at inferring internal network characteristics based on measurements at the edge of the network. In loss tomography, in particular, the characteristic of interest is the loss rate of individual links. There is a significant body of work dedicated to this problem using multicast and/or unicast end-to-end probes. Independently, recent advances in network coding have shown that there are several advantages from allowing intermediate nodes to process and combine, in addition to just forward, packets. In this paper, we pose the problem of loss tomography in networks that have network coding capabilities. We design a framework for estimating link loss rates, which leverages network coding capabilities and we show that it improves several aspects of tomography, including the identifiability of links, the tradeoff between estimation accuracy and bandwidth efficiency, and the complexity of ...

2010-01-01

69

Vehicle tracking systems  

Energy Technology Data Exchange (ETDEWEB)

Several systems have been developed to accomplish vehicle location. The systems consist of three types: Dead Reckoning, Satellite, and LORAN C. If the information is to be sent back to a central location, some type of radiocommunication system is needed. One can use the existing voice radio or add a radio system just for transmitting the data.

1987-01-01

70

Explore - The Lab - Australian Broadcasting Corporation's Gateway to Science  

Wastenet

...Explore - The Lab - Australian Broadcasting Corporation's Gateway to Science Radio TV Shop News Sport Local Children Science Environment more Topics help Science Home News in Science Features Explore TV & Radio Dr Karl Play Podcasts DNA - The discovery of the double helix structure of DNA completely changed biology and opened up the new field of genetics. The 'backbone of life' has given us the human genome, stem cell research, ...

71

Comparison of three methods of remote metering of electrical energy: Telephone line, fiber optic, and radio packet. Final report, June 1995--August 1995  

Energy Technology Data Exchange (ETDEWEB)

This report deals with the selection of a data communication system for a remote metering system. It covers the following three types of systems: fiber optic, telephone line, and radio packet. It provides a methodology for selecting a communication system for a given remote metering system and a method for comparing costs.

1998-07-01

72

Nonthermal emission from the radio relic of the galaxy cluster A2256  

CERN Document Server

We aim to obtain a consistent description of non-thermal emissions from Abell 2256 and to give a prediction for a gamma-ray emission from this galaxy cluster. Assuming that a radio relic illuminates a localization of an ongoing merger, and that both radio and non-thermal part of hard X-ray emission are due to electron component of cosmic rays filling the relic, we derived from radio and hard X-ray properties of the relic in A2256 the magnetic field strength and number densities for relativistic electrons and protons. Due to the interpretation of the radio relic as a structure formed just where a shock front is, we discuss a gamma-ray emission at the cluster periphery. The estimated strength of the magnetic field in the relic is equal to 0.05 \\muG, while the amplitude of the electron number density varies from 3 x 10^{-4} to 3 x 10^{-5} cm^{-3} (respectively for the relic thickness of 50 to 500 kpc). We ...

2011-01-01

73

Biochemical and molecular genetic approaches on the radioprotective mechanism of natural products  

Energy Technology Data Exchange (ETDEWEB)

We reported the radio-protective effect of DTT. The treatment of DTT increased cell survival after gamma-irradiation, decreased in the frequencies of micronucleus, and reduction in DNA fragmentation and apoptotic cells. Induction of apoptosis after UV-C irradiation was revealed by the changes in the relative cell death, increase in the relative amount of apoptotic cells, and the induction of DNA fragmentation. About 100 medicinal plants were purchased and methanol extract samples were prepared. Radio-protective and radio-sensitizing activities of these samples were screened. Seven samples showed above 20% radio-protective activities: Salvia miltiorrhiza, Areca catechu, Cornus officinalis, Alpiniae officinari rhizoma, Meliae fructus, Alpiniae katsumadaii semen, Betulae cortex. Acanthopanax sessiliflous showed the highest radio-sensitizing effect and 10 other samples revealed moderate ...

1999-04-01

74

Uncertainty and Sensitivity of Alternative Rn-222 Flux Density Models Used in Performance Assessment  

Energy Technology Data Exchange (ETDEWEB)

Performance assessments for the Area 5 Radioactive Waste Management Site on the Nevada Test Site have used three different mathematical models to estimate Rn-222 flux density. This study describes the performance, uncertainty, and sensitivity of the three models which include the U.S. Nuclear Regulatory Commission Regulatory Guide 3.64 analytical method and two numerical methods. The uncertainty of each model was determined by Monte Carlo simulation using Latin hypercube sampling. The global sensitivity was investigated using Morris one-at-time screening method, sample-based correlation and regression methods, the variance-based extended Fourier amplitude sensitivity test, and Sobol's sensitivity indices. The models were found to produce similar estimates of the mean and median flux density, but to have different uncertainties and sensitivities. When the Rn-222 effective diffusion coefficient was estimated using five different published predictive models, ...

2007-06-01

75

Prediction of the compressive strength of vertebral bodies of the lumbar spine by quantitative computed tomography.  

Science.gov (United States)

The ultimate compressive strength of 36 thoracolumbar vertebrae was determined experimentally. In addition, the trabecular bone mineral content was measured by single energy quantitative computed tomography. The areas of fractured endplates were also determined by computed tomography. The results show that a linear relationship exists between the compressive strength and the product of bone density and endplate area. These data allow an in vivo prediction of vertebral body strength using a noninvasive method with a standard error of estimate amounting to less than 0.95 kN. PMID:3212488

1988-01-01

76

Computerized tomography of adrenal glands in the investigation of Cushing's syn  

International Nuclear Information System (INIS)

Computerized tomography of the adrenal glands was performed in 10 patients with Cushing's syndrome using a G.E. 8800 CT/T Body Scanner. The tomographic findings of unilateral adrenal masses in 4 patients were confirmed by surgery. In the remaining 6 patients, computerized tomography did not identify any masses, and both glands were well visualized and showed normal shape. In these patients, measurement of the adrenal glands revealed both normal (n=1) and enlarged glands (n=5). The findings of adrenalectomy (n=4) or transphenoidal surgery and follow-up (n=2) established the diagnosis of adrenal phyperplasia in all patients. (Author).

77

Transurethral Ultrasound Diffraction Tomography  

Science.gov (United States)

... [5] GT Gullberg, RH Huesman, DNG Roy, J. Qi and BW Reutter, Esti- mation of the parameter covariance matrix for a one-compartment cardiac ...

2007-03-01

79

Quantitative cerebral blood flow with Optical Coherence Tomography  

UK PubMed Central (United Kingdom)

Absolute measurements of cerebral blood flow (CBF) are an important endpoint in studies of cerebral pathophysiology. Currently no accepted method exists for in vivo longitudinal...Full Text Available

2010-02-01

83

Diagnostic Value of C-reactive Protein in Complicated Appendicitis  

UK PubMed Central (United Kingdom)

PurposeEarly detection of appendicitis has increased due to development of computed tomography and ultrasonography, yet we are frequently meeting complicated appendicitis, including...Full Text Available

2011-06-01

84

Computer tomographic diagnosis of intrathoracic lipoma  

Energy Technology Data Exchange (ETDEWEB)

A case of intrathoracic lipoma in a child is presented. The diagnosis was made before operation by means of computer-assisted tomography, a non-interventional procedure.

1984-04-14

85

Computed Tomography diagnosis of skeletal involvement in multiple myeloma  

International Nuclear Information System (INIS)

The authors assess the role of Computed Topography in the diagnosis and management of multiple myeloma (MM) and investigate if Computed Tomography findings can influence the clinical approach, prognosis and treatment. 273 multiple myeloma patients submitted to Computed Tomography June 1994, to December, 1996. The patients were 143 men and 130 women (mean age: 65 years): 143 were stage I, 38 stage II and 92 stage III according to Durie and Salomon's clinical classification. All patients were submitted to blood tests, spinal radiography and Computed Tomography, the latter with serial 5-mm scans on several vertebral bodies. Computed Tomography despicted vertebral arch and process involvement in 3 cases with the vertebral pedicle sign. Moreover, Computed Tomography proved superior to radiography in showing the spread of myelomatous masses into the soft tissues in a case with solitary ...

1994-06-01

86

The impact of solar flares and magnetic storms on humans  

International Nuclear Information System (INIS)

Three classes of solar emanations, namely, photon radiation from solar flares, solar energetic particles, and inhomogeneities in the solar wind that drive magnetic storms, are examined, and their effects on humans and technological systems are discussed. Solar flares may disrupt radio communications in the HF and VLF ranges. Energetic particles pose a special hazard at low-earth orbit and above, where they can penetrate barriers such as spacesuits and aluminum and destroy cells and solid state electronics. Energetic solar particles also influence terrestrial radio waves propagating through polar regions. Magnetic storms may disturb the operation of navigation instruments, power lines and pipelines, and satellites; they give rise to ionospheric storms which affect radio communication at all latitudes. There is also a growing body of evidence that changes in the geomagnetic field affect biological systems. 3 refs.

87

The Nuclear Outflow in NGC 2110  

CERN Document Server

We present a HST/STIS spectroscopic and optical/radio imaging study of the Seyfert NGC 2110 aiming to measure the dynamics and understand the nature of the nuclear outflow in the galaxy. Previous HST studies have revealed the presence of a linear structure in the Narrow-Line Region (NLR) aligned with the radio jet. We show that this structure is strongly accelerated, probably by the jet, but is unlikely to be entrained in the jet flow. The ionisation properties of this structure are consistent with photoionisation of dusty, dense gas by the active nucleus. We present a plausible geometrical model for the NLR, bringing together various components of the nuclear environment of the galaxy. We highlight the importance of the circum-nuclear disc in determining the appearance of the emission line gas and the morphology of the jet. From the dynamics of the emission line gas, we place constraints on the accelerating mechanism of the outflow and discuss ...

2010-01-01

88

Technical evaluation report for the demonstration of radio frequency soil decontamination at Site S-1  

Energy Technology Data Exchange (ETDEWEB)

The Air Force`s Armstrong Laboratory at Tyndall Air Force Base, Florida, has supported the research and development of Radio Frequency Soil Decontamination. Radio frequency soil decontamination is essentially a heat-assisted soil vapor extraction process. Site S-1 at Kelly Air Force Base, San Antonio, Texas, was selected for the demonstration of two patented techniques. The site is a former sump that collected spills and surface run-off from a waste petroleum, oils, and lubricants and solvent storage and transfer area. In 1993, a technique developed by the IIT Research Institute using an array of electrodes placed in the soil was demonstrated. In 1994, a technique developed by KAI Technologies, Inc. using a single applicator placed in a vertical borehole was demonstrated. Approximately 120 tons of soil were heated during each demonstration to a temperature of about 150 degrees Celsius.

1995-04-01

89

Significant Treatment: An Assessment of Issues-Programs List Availability in Missouri Radio Station Public Inspection Files  

British Library Electronic Table of Contents (United Kingdom)

Over the past three decades, rising competition from television and other new media prompted the FCC to ease the responsibilities of radio stations to maintain extensive records of issues programming, while retaining the responsibility of stations to provide ready public access to records. This study investigated the availability of Issues-Programs Lists in nearly 100 Missouri radio station Public Files. One in five randomly sampled stations failed to produce access to Lists upon demand as required under federal law. Noncompliance themes include: Inability to access Public Files within 20 minutes of face-to-face requests; station personnel with limited or no knowledge of Files; denial of access to Files and Lists (i.e., verbal refusals, locked studio doors); and incomplete Files. The rate ...

2007-01-01

90

Jets and accretion processes in Active Galactic Nuclei further clues  

CERN Document Server

We present evidence in favour of a link between the luminosity radiatively dissipated in the central engine of radio-loud Active Galactic Nuclei and the kinetic power in their jets. This piece of evidence is based on the relation we find between the luminosity in broad emission lines and the kinetic power in pc-scale radio jets, for a sample of radio-loud quasars for which suitable data are available in the literature. We find that the ionizing luminosity and the kinetic one are of the same order of magnitude, suggesting that the processes responsible for them are somehow related. A strong magnetic field in equipartition with the radiation field could be responsible for regulating both processes. BL Lac objects seem to follow a similar behaviour, but with comparatively fainter broad line emission.

1996-01-01

91

Ionized gas and radio emission in the barred Seyfert galaxy NGC 5728  

International Nuclear Information System (INIS)

This paper reports extensive new optical and radio observations of NGC 5728, emphasizing the central regions. Deep photographs revealing detail in the faint spiral arms are briefly discussed. Broad-band UBV CCD images obtained to examine the colors of the stellar populations that comprise the bar and central ring are presented. The velocity field and emission maps obtained from imaging spectroscopic measurements in the H-alpha emission line are discussed. Conventional long-slit spectra covering the ionized gas in the nuclear region are described. Detailed maps of the radio emission in the central regions of NGC 5728 are presented. These combined data provide considerable evidence for the inflow of gas into the nuclear region, in response to the nonaxisymmetric gravitational potential of the bar. The possible relation of this phenomenon to the Seyfert nature of NGC 5728 is also considered. 48 references.

92

Cyclic Spectral Analysis of Radio Pulsars  

CERN Document Server

Cyclic spectral analysis is a signal processing technique designed to deal with stochastic signals whose statistics vary periodically with time. Pulsar radio emission is a textbook example of this signal class, known as cyclostationary signals. In this paper, we discuss the application of cyclic spectral analysis methods to pulsar data, and compare the results with the traditional filterbank approaches used for almost all pulsar observations to date. In contrast to standard methods, the cyclic spectrum preserves phase information of the radio signal. This feature allows us to determine the impulse response of the interstellar medium and the intrinsic, unscattered pulse profile directly from a single observation. We illustrate these new analysis techniques using real data from an observation of the millisecond pulsar B1937+21.

2011-01-01

93

X-ray, Optical, and Radio Observations of SN 1999em and SN 1998S  

CERN Document Server

Observations of the Type II-P (plateau) Supernova (SN) 1999em and Type IIn (narrow emission line) SN 1998S have enabled estimation of the profile of the SN ejecta, the structure of the circumstellar medium (CSM) established by the pre-SN stellar wind, and the nature of the shock interaction. SN 1999em is the first and only Type II-P detected at both X-ray and radio wavelengths. It is the least radio luminous and one of the least X-ray luminous SN ever detected (except for the unusual and very close SN 1987A). The Chandra X-ray data indicate non-radiative interaction of SN ejecta with a power-law density profile (rho \\propto r^{-n} with n ~ 7) with a pre-SN wind with a low mass loss rate of ~2 \\times 10^{-6} Msun/yr for a wind velocity of 10 km/sec, in close agreement with radio mass-loss rate estimates. The Chandra data show an unexpected, temporary rise in the 0.4--2.0 keV X-ray flux at ~100 days after explosion. SN ...

2001-01-01

94

The infrared-dominated jet of 3C401  

CERN Document Server

We present a Hubble Space Telescope image of the FRII radio galaxy 3C 401, obtained at 1.6 microns with the NICMOS camera in which we identify the infrared counterpart of the brightest region of the radio jet. The jet has a complex radio structure and brightens where bending occurs, most likely as a result of relativistic beaming. We analyze archival data in the radio, optical and X-ray bands and we derive its spectral energy distribution. Differently from all of the previously known optical extragalactic jets, the jet in 3C401 is not detected in the X-rays even in a long 48ksec X-ray Chandra exposure and the infrared emission dominates the overall SED. We propose that the dominant radiation mechanism of this jet is synchrotron. The low X-ray emission is then caused by two different effects: i) the lack of any strong external photon field and ii) the shape of the electron distribution. This affects the ...

2005-01-01

95

TELEMETRY LINK FOR Howard A. Baldwin and Robert W. - NASA ...  

Science.gov (United States)

Howard A. Baldwin and Robert W. Freyman. (NASA-CR-138152) TELEMERY LINK FOR AN. 574-2179 9 ..... Baldwin, H.A., "Long Range Radio Tracking of ...

96

Scintillation Velocity of PSR B0329+54  

Science.gov (United States)

We monitored PSR B0329+54 for one year using the Nanshan 25-m radio telescope, the scintillation velocity V ISS shows evidence of systematic variation with the day of the year. States of interstellar medium (ISM) are discussed.

2011-07-01

97

Radio frequency noise from an MLC: a feasibility study of the use of an MLC for linac-MR systems  

UK PubMed Central (United Kingdom)

Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a...Full Text Available

2010-02-21

98

RESOLVING DOPPLER-FACTOR CRISIS IN ACTIVE GALACTIC NUCLEI: NON-STEADY MAGNETIZED OUTFLOWS  

International Nuclear Information System (INIS)

Magnetically driven non-stationary acceleration of jets in active galactic nuclei results in the leading parts of the flow being accelerated to much higher Lorentz factors than in the case of steady-state acceleration with the same parameters. The higher Doppler-boosted parts of the flow may dominate the high-energy emission of blazar jets. We suggest that highly variable GeV and TeV emission in blazars is produced by the faster moving leading edges of highly magnetized non-stationary ejection blobs, while the radio data trace the slower-moving bulk flow. Thus, the radio and gamma-ray emission regions have different, but correlated, Doppler factors. High-energy emission is generated, typically within the optically thick core, in the outer parts of the broad-line emission region, avoiding the radiative drag on the faster parts of the flow. The radio emission should correlate with the gamma-ray emission, delayed with ...

2010-10-10

99

No short-term effects of digital mobile radio telephone on the awake human electroencephalogram  

Energy Technology Data Exchange (ETDEWEB)

A recent study reported the results of an exploratory study of alterations of the quantitative sleep profile due to the effects of a digital mobile radio telephone. Rapid eye movement (REM) was suppressed, and the spectral power density in the 8--13 Hz frequency range during REM sleep was altered. The aim of the present study was to illuminate the influence of digital mobile radio telephone on the awake electroencephalogram (EEG) of healthy subjects. For this purpose, the authors investigated 34 male subjects in a single-blind cross-over design experiment by measuring spontaneous EEGs under closed-eyes condition from scalp positions C{sub 3} and C{sub 4} and comparing the effects of an active and an inactive digital mobile radio telephone (GSM) system. During exposure of nearly 3.5 min to the 900 MHz electromagnetic field pulsed at a frequency of 217 Hz and with a pulse width of 580 {micro}s, the authors could not detect ...

1997-05-01

100

National Institutes of Health (NIH) Health Matters Podcasts  

Science.gov (United States)

60 http://www.nih.gov/news/radio/healthmatters/index.htm 60-second Health Matters spots-one unique health report for each weekday of the month. en-us 2010 Mon, 01 Feb 2010 12:00:00...

2011-08-26

101

Limits on the Diffuse Radio and Hard X-ray Emission of Abell 2199  

CERN Document Server

The Westerbork Northern Sky Survey (WENSS) and the NRAO/VLA Sky Survey (NVSS) were used to determine an upper limit to the diffuse radio flux from the nearby cluster Abell 2199. For the entire cluster, this limit is <3.25 Jy at 327 MHz from WENSS; for the inner 15' radius, the limit is <168 mJy at 1.4 GHz. These limits are used to constrain the cluster magnetic field by requiring that the radio flux be consistent with the hard X-ray (HXR) flux observed by BeppoSAX, assuming that the observed HXR excess is due to inverse Compton (IC) scattering of cosmic microwave background photons by relativistic electrons in the intracluster gas. We find that the magnetic field must be very weak (<0.073 uG) in order to avoid producing an observable radio halo. We also consider the possibility that the HXR excess is due to nonthermal bremsstrahlung (NTB) by a population of suprathermal electrons which are being accelerated to ...

1999-01-01

102

Effect of #gamma#-irradiation on relaxation properties of sealants on organosilicon rubber base  

International Nuclear Information System (INIS)

The dielectrical properties of organosilicon sealants have been studied in the wide range of temperatures in the low and radio frequencies range. The effect of thermal treatment and #gamma#-irradiation on these properties is discussed.

103

Chandra Observations of Nuclear X-ray Emission from a Sample of Radio Sources  

CERN Document Server

We present the X-ray properties of a sample of 17 radio sources observed with the Chandra X-ray Observatory as part of a project aimed at studying the X-ray emission from their radio jets. In this paper, we concentrate on the X-ray properties of the unresolved cores. The sample includes 16 quasars (11 core-dominated and 5 lobe-dominated) in the redshift range z=0.30--1.96, and one low-power radio-galaxy at z=0.064. No diffuse X-ray emission is present around the cores of the quasars, except for the nearby low-power galaxy that has diffuse emission on a scale and with a luminosity consistent with other FRIs. No high-amplitude, short-term variability is detected within the relatively short Chandra exposures. However, 1510-089 shows low-amplitude flux changes with a timescale of $\\sim$25 minutes. The X-ray spectra of the quasar cores are generally well described by a single power law model with Galactic absorption. However, ...

2003-01-01

104

A search for electron cyclotron maser emission from compact binaries  

CERN Document Server

Unipolar induction (UI) is a fundamental physical process, which occurs when a conducting body transverses a magnetic field. It has been suggested that UI is operating in RX J0806+15 and RX J1914+24, which are believed to be ultra-compact binaries with orbital periods of 5.4 min and 9.6 min respectively. The UI model predicts that those two sources may be electron cyclotron maser sources at radio wavelengths. Other systems in which UI has been predicted to occur are short period extra-solar terrestrial planets with conducting cores. If UI is present, circularly polarised radio emission is predicted to be emitted. We have searched for this predicted radio emission from short period binaries using the VLA and ATCA. In one epoch we find evidence for a radio source, coincident in position with the optical position of RX J0806+15. Although we cannot completely exclude that this is a chance alignment between ...

2007-01-01

105

Electromagnetic characterization of superconducting radio-frequency cavities for gw detection  

International Nuclear Information System (INIS)

The electromagnetic properties of a prototype gravitational wave detector, based on two coupled superconducting microwave cavities, were tested. The radio-frequency (rf) detection system was carefully analysed. With the use of piezoelectric crystals small harmonic displacements of the cavity walls were induced and the parametric conversion of the electromagnetic field inside the cavities explored. Experimental results of bandwidth and sensitivity of the parametric converter versus stored energy and voltage applied to the piezoelectric crystal are reported. A rf control loop, developed to stabilize phase changes on signal paths, gave a 125 dBc rejection of the drive mode on a time scale of 1 h.

2004-03-07

106

A peculiar distribution of radial velocities of faint radio-galaxies with 13.0<=msub(corr)<=15.5  

International Nuclear Information System (INIS)

A sample of 41 radio-galaxies with 13.0<=msub(corr)<=15.5 has been analyzed to test the angular redshift anisotropy discovered on Sc I galaxies by Rubin, Rubin and Ford (1973). The sample does not present their anisotropy but contains an even more curious distribution of radial velocities which suggests that the Rubin-Ford effect results from an anomalous redshift of light when it travels through clusters of galaxies. (Auth.).

107

5 GHz 200 Mbit/s radio over polymer fibre link with envelope detection at 650 nm wavelength  

DEFF Research Database (Denmark)

All-optical envelope detection of a 5 GHz 200 Mbit/s modulated radio frequency signal is achieved using a 650 nm resonant cavity light emitting diode. Error-free transmission is achieved over a 50 m-long link of 1 mm diameter graded index polymer optical fibre (POF). The presented system has potential applications in low cost and low complexity short range wireless and wireline POF-based transmission links.

2008-01-01

108

Significance of cranial computer tomography for the early diagnosis of peri- and postnatal damage  

Energy Technology Data Exchange (ETDEWEB)

It is reported on examination-technical possibilities with craniocerebral Computer Tomography in the peri- and postnatal period. Some typical tomographic images from a 17 1/2 months period in our own patient material of 327 children are demonstrated. The special advantages of this new technical-extensive method are: exact diagnoses, observation possibility of the longitudinal section, and the absolute harmlessness to the child.

1981-01-01

109

Selection of dimensions of scintillation detectors and of the correction energy with the use of the dual energy method in computerized tomography  

Science.gov (United States)

The article explains the method of selecting the optimum energy for correcting the energy selectivity of tomographic projection and the optimum length of the crystals corresponding to it when the dual energy method in computerized tomography is used. Results of numerical calculations for actual materials and count results are presented.

1986-05-01

110

Incidental orbital calcifications on computed tomography scans; Calcificacoes orbitarias incidentais na tomografia computadorizada  

Energy Technology Data Exchange (ETDEWEB)

We retrospectively studied the computed tomography scans of the orbit in 75 patients in order to identify the presence of incidental calcifications (scleral and trochlear apparatus calcifications.). These imaging findings should integrate the vast list of differential diagnosis of orbital calcifications, as they may help radiologists to distinguish these calcifications from orbital foreign bodies. (author)

2001-02-01

111

From tomography to voludensitometry: radiation detectors for industrial control and medical instrumentation; De la tomographie a la voludensitometrie: les capteurs pour le controle industriel et l`instrumentation medicale  

Energy Technology Data Exchange (ETDEWEB)

In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).

1993-12-01

112

Estimation of errors provided with dead times of roentgen digital tomography  

International Nuclear Information System (INIS)

Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computer tomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained

113

Differential diagnosis of tumorous lesions in the iliac bone in children  

Energy Technology Data Exchange (ETDEWEB)

The radiologic appearance of inflammatory and tumorous lesions in the iliac bone is characterized by destructive alterations and consolidations simultaneously. This pattern is nonspecific. The value of plain films of this area is compromised by the anatomy of the iliac bone and by overlying structures. Therefore tomography, computer tomography and bone scans are necessary. Difficulties in differentiation between benign and malignant lesions are discussed and case reports are given. The importance of histologic examination is stressed.

1984-02-01

114

Detection of drugs and explosives using neutron computerized tomography and artificial intelligence techniques  

International Nuclear Information System (INIS)

In this study the development of a methodology to detect illicit drugs and plastic explosives is described with the objective of being applied in the realm of public security. For this end, non-destructive assay with neutrons was used and the technique applied was the real time neutron radiography together with computerized tomography. The system is endowed with automatic responses based upon the application of an artificial intelligence technique. In previous tests using real samples, the system proved capable of identifying 97% of the inspected materials.

2010-06-01

115

Computer tomography of orbita in children  

Energy Technology Data Exchange (ETDEWEB)

The experiences are described of the examination of orbita in children using computer tomography (CT). Over a period of four years 42 examinations were performed of children in the age ranging between 7 months and 15 years, i.e., 2.7 percent of all CT examinations performed. The highest diagnostic yield was in orbita tumours. The possibilities of CT are demonstrated on examples.

1983-07-01

116

Computed tomography in migratory disorders of human brain development  

International Nuclear Information System (INIS)

Computed tomographic findings in developmental brain anomalies are more easily classified when the system used is based on embryogenesis related to morphology. Analysis of computed tomographic findings in a series of 154 patients with brain anomalies (Chiari malformation not included) revealed that specific examples of abnormalities occurring in major stages of brain development may be recognized by computed tomography. This paper deals with a group of patients with abnormalities that reflect a disturbance in neuronal migration. (orig.).

117

Computed tomography - old ideas and new technology  

International Nuclear Information System (INIS)

Several recently introduced 'new' techniques in computed tomography - iterative reconstruction, gated cardiac CT, multiple-source, and dual-energy CT - actually date back to the early days of CT. We review the historic origins and evolution of these techniques, which may provide some insight into the latest innovations in commercial CT systems. (orig.)

2011-03-01

118

Compton scatter tomography and its inversion using a few projections  

Energy Technology Data Exchange (ETDEWEB)

Compton scatter tomography utilizes the electronic collimation characteristics available through the Compton scattering angle-energy correlation to obtain tomographic images. In this work we present particular aspects of the technique, which are relevant to the inverse radiation transport problem of reducing marginal projection data to radial two-phase flow regime maps. The results indicate a viable technique for the tomographic imaging of tow-phase flow using practical source strengths and reasonably few detectors.

1988-01-01

119

Radiofrequency electromagnetic fields in the Cookridge area of Leeds  

Energy Technology Data Exchange (ETDEWEB)

On the 8 and 9 May 2002 representatives of the National Radiological Protection Board (NRPB) performed a radiofrequency electromagnetic field survey in the Cookridge area of Leeds in order to assess exposure to radio signals from transmitters mounted on a water tower/a lattice tower and a radio station tower. Guidelines on limiting exposure to radio signals have been published by NRPB and the International Commission on Non-Ionizing Radiation Protection (ICNIRP). These guidelines are designed to prevent established adverse effects on human health. During this survey, the total exposures due to all radio signals from 30 MHz to 18000 MHz (18 GHz) were measured. This frequency range was chosen as it includes mobile phone base station transmissions, which are at around 900 and 1800 MHz and super high frequency (SHF) transmissions from most of the large microwave dish antennas mounted on the towers. In ...

2002-07-01

120

Field investigation of radio network usage at the dismounted infantry section level  

Science.gov (United States)

The Soldier Information Requirements Technology Demonstration (SIREQ TD) project is an experimentation program to identify technologies that significantly enhance the performance of our future soldiers. One of the study series involved a 2 x 2 factorial comparison of the benefits of digital maps over paper maps, and the use of radios vs. no radios. Thirty-two Canadian regular force infantry soldiers performed force-on-force tactical assault missions in wooded terrain, with each soldier participating in all four test conditions. The radios were configured to operate in 4 subnets: 1 channel for each of the 2 Assault Groups (4 soldiers on a channel); a Section Commander/2IC channel; and an all-users channel. Note that in the no-radio conditions soldiers still operated the press-to-talk switch to allow recording of communications, but the speaker volume was set to zero. All communications were date/time ...

2006-06-01

121

Seismic tomography inversion in the case that sources and receivers are distributed out of a 2-D plane; Shingen jushinten ga nijigen heimennai ni nai baai no danseiha tomography kaiseki ni kansuru kosatsu  

Energy Technology Data Exchange (ETDEWEB)

In the case where sources and receivers are not distributed on a 2-D plane, seismic tomography inversion was studied. In tomography experiments, the existing wells are generally used. In such case, sources and receivers are frequently not distributed on a 2-D plane. The 2.5-D analysis method including 2-D structure and 3-D ray-tracing was thus developed. This method is featured by less memory necessary for ray-tracing calculation, and the same algorithm for velocity determination as 2-D analysis method. In previous methods, since analysis is generally carried out by projecting sources and receivers on a certain assumed 2-D plane, it can derive correct results in the case of constant velocity and straight ray, however, in the other case, it derives incorrect results. Application of 3-D tomography requires a large amount of memory, and falls into poor convergence because of various parameters. The 2.5-D analysis method can ...

1996-10-01

122

Computerized Tomography versus unenhanced and enhanced fast MRI sequences in the study of liver metastases: Qualitative and quantitative analyses  

International Nuclear Information System (INIS)

The authors compared unenhanced and contrast-enhanced fast MRI and Computerized Tomography in the detection of liver metastases. Eleven patients with single or multiple hepatic lesions (42 in all) were submitted to V and magnetic resonance studies; T1- and T2- weighted TSE, T2-weighted TSE with fat suppression, unenhanced breath-hold TFE and early or delayed enhanced breath-hold TFE images were acquired with a 1.5 T superconductive magnet (Philips NT). The quantitative analysis of all magnetic resonance images was performed for contrast/noise ratio (CNR) and number of detected lesions; magnetic resonance and Computerized Tomography images were also compared qualitatively for lesion conspicuity, anatomical structure identification and artifacts. The results were compared with Student's test. Early enhanced breath-hold TFE was statistically superior to T1-weighted TSE (p = .0009), T2-weighted TSE (p = .01) and Computerized ...

1997-01-01

123

PET/MRI hybrid imaging: devices and initial results  

British Library Electronic Table of Contents (United Kingdom)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...

2008-01-01

124

Evaluation of bone mineral content using Quantitative Computed Tomography  

International Nuclear Information System (INIS)

The authors have evaluated bone mineral content in the vertebral spongiosa by means of Computed Tomography. The method proposed by Genant and Cann [17, 18] has been applied to examine 164 healthy volunteers and 108 patients. Both healthy males and females showed a progressive bone mineral loss increasing with age; the bone mineral loss was most severe in females during the 4th and 5th decade of life. Pathology included patients with osteoporotic fractures (vertebral and femural neck), patients with partial gastrectomy, renal failure, primary hyperparathyroidism, Cushing syndrome, corticosteroid therapy. Bone mineral values were significantly lower in most pathologic groups. Computed Tomography proves thus to be a valuable method to assess bone mineral content and to identify patients at risk for fractures.

1988-01-01

125

The Prevalence of Concha Bullosa and Nasal Septal Deviation and Their Relationship to Maxillary Sinusitis by Volumetric Tomography  

UK PubMed Central (United Kingdom)

The objective of this study was to determine the prevalence of concha bullosa and nasal septal deviation and their potential relationships to maxillary sinusitis. 883 CT scans taken at Creighton University...Full Text Available

2010-01-01

126

TLD assessment of mouse dosimetry during microCT imaging  

UK PubMed Central (United Kingdom)

Advances in laboratory animal imaging have provided new resources for noninvasive biomedical research. Among these technologies is microcomputed tomography (microCT) which is widely used to obtain high...Full Text Available

2008-09-01

127

Relation between frequency of seismic wave and resolution of tomography; Danseiha tomography kaiseki ni okeru shuhasu to bunkaino no kankei  

Energy Technology Data Exchange (ETDEWEB)

With regard to the elastic wave exploration, discussions have been given on the relationship between frequency and resolution in P-wave velocity tomography using the initial travel time. The discussions were carried out by using a new analysis method which incorporates the concept of Fresnel volume into tomography analysis. The following two arrangements were used in the calculation: a cross hole arrangement, in which seismic source and vibration receiving points were arranged so as to surround the three directions of a region extending 250 m in the horizontal direction and 500 m in the vertical direction, and observation is performed between two wells, and a permeation VSP arrangement in which the seismic source is installed on the ground surface and receiving points installed in wells. Restructuring was performed on the velocity structure by using a total of 819 observation travel times. This method has derived results of the restructuring ...

1997-05-27

128

Range accuracy in carbon ion treatment planning based on CT-calibration with real tissue samples  

UK PubMed Central (United Kingdom)

BackgroundThe precision in carbon ion radiotherapy depends on the calibration of Hounsfield units (HU) as measured with computed tomography (CT) to water equivalence. This calibration...Full Text Available

129

Quantification of lung surface area using computed tomography  

UK PubMed Central (United Kingdom)

ObjectiveTo refine the CT prediction of emphysema by comparing histology and CT for specific regions of lung. To incorporate both regional lung density measured by CT and cluster...Full Text Available

2010-01-01

130

Noise suppression in scatter correction for cone-beam CT  

UK PubMed Central (United Kingdom)

Scatter correction is crucial to the quality of reconstructed images in x-ray cone-beam computed tomography (CBCT). Most of existing scatter correction methods assume smooth scatter distributions. The...Full Text Available

2009-03-01

131

Limitations of Tc99m-MIBI-SPECT Imaging Scans in Persistent Primary Hyperparathyroidism  

UK PubMed Central (United Kingdom)

BackgroundIn primary hyperparathyroidism (PHPT) the predictive value of technetium 99m sestamibi single emission computed tomography (Tc99m-MIBI-SPECT) for localizing pathological...Full Text Available

2011-01-01

132

Iofetamine I 123 single photon emission computed tomography is accurate in the diagnosis of Alzheimer's disease  

Energy Technology Data Exchange (ETDEWEB)

To determine the diagnostic accuracy of iofetamine hydrochloride I 123 (IMP) with single photon emission computed tomography in Alzheimer's disease, we studied 58 patients with AD and 15 age-matched healthy control subjects. We used a qualitative method to assess regional IMP uptake in the entire brain and to rate image data sets as normal or abnormal without knowledge of subjects'clinical classification. The sensitivity and specificity of IMP with single photon emission computed tomography in AD were 88% and 87%, respectively. In 15 patients with mild cognitive deficits (Blessed Dementia Scale score, less than or equal to 10), sensitivity was 80%. With the use of a semiquantitative measure of regional cortical IMP uptake, the parietal lobes were the most functionally impaired in AD and the most strongly associated with the patients' Blessed Dementia Scale scores. These results indicated that IMP with single photon ...

1990-04-01

133

Fourier-Domain Optical Coherence Tomography and Adaptive Optics Reveal Nerve Fiber Layer Loss and Photoreceptor Changes in a Patient With Optic Nerve Drusen  

UK PubMed Central (United Kingdom)

BackgroundNew technology allows more precise definition of structural alterations of all retinal layers although it has not been used previously in cases of optic...Full Text Available

2008-06-01

134

Feature-based rectal contour propagation from planning CT to cone beam CT  

UK PubMed Central (United Kingdom)

The purpose of this work is to develop a novel feature-based registration strategy to automatically map the rectal contours from planning computed tomography (CT) (pCT) to cone beam CT (CBCT). The rectal...Full Text Available

2008-10-01

135

Evaluation of Tumor Micro-Environment in an Animal Model using a Nanoparticle Contrast Agent in Computed Tomography Imaging  

UK PubMed Central (United Kingdom)

RATIONALE AND OBJECTIVESNon-invasive longitudinal imaging of tumor vasculature could provide new insights into the development of solid tumors, facilitating efficient...Full Text Available

2011-01-01

136

Enhanced CT and CT virtual endoscopy in diagnosis of heterotopic pancreas  

UK PubMed Central (United Kingdom)

AIM: To improve the diagnosis of heterotopic pancreas by the use of contrast-enhanced computed tomography (CT) imaging and CT virtual endoscopy (CTVE).METHODS: A total of six patients with heterotopic...Full Text Available

2011-09-07

137

Effects of Age on Optical Coherence Tomography Measurements of Healthy Retinal Nerve Fiber Layer, Macula and Optic Nerve Head  

UK PubMed Central (United Kingdom)

PurposeTo determine the effects of age on global and sectoral peripapillary retinal nerve fiber layer (RNFL), macular thicknesses and optic nerve head (ONH) parameters...Full Text Available

2009-06-01

138

Characteristics of common solid liver lesions and recommendations for diagnostic workup  

UK PubMed Central (United Kingdom)

Due to the widespread clinical use of imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available

2009-07-14

139

CT evaulation of thoracic and abdominal fatty masses  

International Nuclear Information System (INIS)

The diagnostic accuracy of computed tomography (CT) in several patterns of thoracic and abdominal fatty masses, has been examined. In selected cases our findings overlap the features of the recent literature. The possibility of surgical therapy in peculiar cases of adipose deposits, commonly esteemed benign, is considered.

1986-01-01

140

CLINICAL VALUE, NORMATIVE RETINAL SENSITIVITY VALUES, AND INTRASESSION REPEATABILITY USING A COMBINED SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY/SCANNING LASER OPHTHALMOSCOPE MICROPERIMETER  

UK PubMed Central (United Kingdom)

PurposeTo establish normative values for macular light sensitivity and to determine the intrasession fluctuation of perimetric responses using the OPKO/OTI microperimeter.Full Text Available

2011-02-01

141

Assessment of the value of various tomography modalities for diagnostic evaluation of the female genital system  

International Nuclear Information System (INIS)

The comprehensive survey explains the indications and the specific value of the modern tomographic modalities with respect to the various diagnostic issues. Numerous reproductions of CT, MRI, US scans illustrate the aspects discussed. (orig./CB)

2001-09-01

142

An unusual presentation of metastatic adenocarcinoma of lung: a case report  

UK PubMed Central (United Kingdom)

We report an unusual patient with primary adenocarcinoma of lung causing malignant pleural and pericardial effusions. The diagnosis was made only at autopsy as his staging computed tomography scan of...Full Text Available

143

Altered myocardial substrate metabolism is associated with myocardial dysfunction in early diabetic cardiomyopathy in rats: studies using positron emission tomography  

UK PubMed Central (United Kingdom)

BackgroundIn vitro data suggest that changes in myocardial substrate metabolism may contribute to impaired myocardial function in diabetic cardiomyopathy (DCM)....Full Text Available

144

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT  

UK PubMed Central (United Kingdom)

Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available

2010-01-01

145

Polarised foreground removal at low radio frequencies using rotation measure synthesis: Uncovering the signature of hydrogen reionisation  

CERN Document Server

Measurement of redshifted 21-cm emission from neutral hydrogen promises to be the most effective method for studying the reionisation history of hydrogen and, indirectly, the first galaxies. These studies will be limited not by raw sensitivity to the signal, but rather, by bright foreground radiation from Galactic and extragalactic radio sources and the Galactic continuum. In addition, leakage due to gain errors and non-ideal feeds conspire to further contaminate low-frequency radio obsevations. This leakage leads to a portion of the complex linear polarisation signal finding its way into Stokes I, and inhibits the detection of the non-polarised cosmological signal from the epoch of reionisation. In this work, we show that rotation measure synthesis can be used to recover the signature of cosmic hydrogen reionisation in the presence of contamination by polarised foregrounds. To achieve this, we apply the rotation measure synthesis technique to ...

2010-01-01

146

Nigerian Urban Women's Use of Information Media: The Challenges for Women in Leadership  

Science.gov (United States)

The study surveyed urban women's use of information media and drew attention to the implications for women in leadership positions and non-formal education. A questionnaire containing structured and unstructured items was administered to 300 women resident at Nsukka urban town Enugu State, Nigeria. One hundred and twenty-five usable copies were used for the data analysis. The findings show that oral media are the most popular among women irrespective of level of education and type of occupation. The level of education influenced the use of radio and television. Popular radio and television programmes among women include newscasts, socio-cultural programmes, music and drama. Problems hindering women's use of radio and television include time constraint, poor reception, poor condition of available sets and lack of money for repairs among others. Based on these findings the implication for the achievement of the Universal ...

2008-10-01

147

High Spatial Resolution Optical and Radio Imagery of the Circumbinary Environment  

CERN Document Server

In this review, I concentrate on describing observations of spatially resolved emission in symbiotic stars at sub-arcsecond scales. In some of the closer objects, the highest resolutions discussed here correspond to linear dimensions similar to the supposed binary separation. A total of 17 stars well accepted as symbiotics are now observed to show sub-arcsecond structure, almost twice the number at the time of the last review in 1987. Furthermore, we now have access to HST imagery to add to radio interferometry. From such observations we can derive fundamental parameters of the central systems, investigate the variation of physical parameters across the resolved nebulae and probe the physical mechanisms of mass loss and interactions between ejecta and the circumstellar medium. Suggestions for future work are made and the potential of new facilities in both the radio and optical domains is described. This review complements that by Corradi (this ...

2004-01-01

148

Development of enhanced radioprotectors - Biochemical and molecular genetical approaches on the radioprotective mechanism of natural products  

Energy Technology Data Exchange (ETDEWEB)

To identify radio-protective agent candidate among medicinal plants and to elucidate the mechanism of action of the candidate material by using modern biochemical and molecular biological methods, we screened radio-protective activity among 48 medicinal plants. Seven samples showed above 20% protective activities against oxidative cell damage: Euryale ferox, Glycyrrhiza uralensis, Salvia miltiorrhiza, Eucomia ulmoides, Paeonia suffruticosa, Spirodela polyrrhiza, and Nelumbo nucifera. We also screened for oxidative stress sensitizing activity among other 51 medicinal plants. Among those samples, 11 samples showed good sensitizing effect; Melia azedarach, Agastache rugosa, Catalpa ovata, Prunus persica, Sinomenium acutum, Pulsatilla koreana, Oldenlandia diffusa, Anthriscus sylvestris, Schizandra chinensis, Gleditsia sinensis, and Cridium officinale. We also reported the radio-protective effect of DTT. The treatment of DTT ...

2000-04-01

149

An alternative explanation of the COBE data  

Energy Technology Data Exchange (ETDEWEB)

The COBE data on cosmic background radiation (CBR) isotropy and spectrum are generally considered to be explicable only in the context of the Big Bang theory and to be confirmation of that theory. However, this data can also be explained by an alternative, non-Big Bang model which hypothesizes an intergalactic radio-absorbing and scattering medium. Dense, force-free magnetic filaments generated by quasars, active galactic nuclei and Herbig-Haro objects can remain stable in the intergalactic medium for many Gy. They will be opaque to radiation with wavelengths longer than 100--400 microns, and essentially transparent to shorter wavelengths. They are thus capable of thermalizing and isotropizing the cosmic background radiation, and of accounting for the observed decrease of radio luminosity of galaxies within increasing distance from earth. A simple, inhomogeneous model of such an absorbing medium can reproduce both the isotropy and spectrum of ...

1994-12-31

150

A relativistic mixing-layer model for jets in low-luminosity radio galaxies  

CERN Document Server

We present an analytical model for jets in Fanaroff & Riley Class I (FRI) radio galaxies, in which an initially laminar, relativistic flow is surrounded by a shear layer. We apply the appropriate conservation laws to constrain the jet parameters, starting the model where the radio emission is observed to brighten abruptly. We assume that the laminar flow fills the jet there and that pressure balance with the surroundings is maintained from that point outwards. Entrainment continuously injects new material into the jet and forms a shear layer, which contains material from both the environment and the laminar core. The shear layer expands rapidly with distance until finally the core disappears, and all of the material is mixed into the shear layer. Beyond this point, the shear layer expands in a cone and decelerates smoothly. We apply our model to the well-observed FRI source 3C31 and show that there is a self-consistent solution. We derive ...

2009-01-01

151

Vascular injuries in intestinal obstruction. The role of computed tomography; Complicazioni vascolari nelle occlusioni intestinali: ruolo della tomografia computerizzata  

Energy Technology Data Exchange (ETDEWEB)

The paper investigates computerized tomography capabilities in showing vascular complications secondary to intestinal obstruction and for assessing the site and cause of obstruction. [Italian] Scopo del lavoro e' lo studio dell'uso della tomografia computerizzata nel riconoscimento di complicanze vascolari secondarie ad occlusione intestinale e della presenza, della natura e della sede dell'ostacolo alla canalizzazione intestinale.

1999-09-01

152

Three-dimensional cranio-facial computed tomography  

International Nuclear Information System (INIS)

Computed tomography allows today to reconstruct three-dimensional (eD) images fram axial scans. The authors report their experience in cranio-facial pathology achived in two Departments of Radiology (University of Trieste, Italy and University of Standford, California). 3D images have been realized using two different softwares, one of which allows to reconstruct both soft tissue and bone structures. The application in maxillo-facial traumas, cranio-facial malformations and head tumours are disscussed. 3D images turned out to be very useful for the optimal visualization and for the spatial demostration of the lesion and have potential applications in cranio-facial surgery and radiotherapy.

1986-01-01

153

The value of computed tomography in the diagnosis of grating scapula  

Energy Technology Data Exchange (ETDEWEB)

Snapping or grating scapula is a condition of the shoulder girdle in which the patient complains of pain and an audible snapping sound which may be associated with pain. We evaluated the diagnostic value of the computed tomography (CT) scans using the clinical diagnosis of a grating scapula as the gold standard. This retrospective study reports the sensitivity, specificity, likelihood ratio and receiver operator characteristic curve for the CT scans and the k value as a measure of the interobserver agreement. None of the parameters validated the examination. We therefore concluded that CT scans are inappropriate for differentiation between a grating scapula and a normally functioning shoulder except in cases where bony abnormalities are present. (orig.)

1994-07-01

154

Spiral CT with three-dimensional and multiplanar reconstruction in the diagnosis of anterior chest wall joint and bone disorders  

Energy Technology Data Exchange (ETDEWEB)

Twenty-seven patients with symptoms or clinical findings suggesting joint or bone disorders of the anterior chest wall (ACW) were evaluated by spiral CT with 3-dimensional (3-D) and multiplanar reconstructions. Preceding conventional ACW tomography was performed in 10 patients. ACW joint and bone changes were visualized more adequately by coronal 2-D reconstructions based on spiral CT than by conventional tomography. In addition, nonossified costal cartilages and soft tissue lesions were demonstrated. 3-D reconstructions sometimes added information, especially in patients with fracture and dislocation. (orig.).

1994-09-01

155

PET/CT-guided interventional procedures: rationale, justification, initial study, and research plan  

International Nuclear Information System (INIS)

Positron-emission tomography (PET) and PET/CT (computed tomography) are becoming increasingly important for diagnosis and treatment of cancer. Clinically relevant changes can sometimes be seen on PET that are not seen on other imaging modalities. However, PET is not suitable for guiding biopsy as the images are not obtained in real-time. Therefore, our research group has begun developing a concept for PET/CT-guided interventional procedures. This paper presents the rationale for this concept, outlines our research plan, and includes an initial study to evaluate the relative sensitivity of CT and PET/CT in detecting suspicious lesions. (orig.)

2007-06-01

156

PET/CT cardiology: an area whose boundaries are still out of sight  

International Nuclear Information System (INIS)

Positron emission tomography (PET) and X-ray computed tomography (CT) performed with PET/CT cameras allow us to obtain concurrently information on the presence and degree of alterations of myocardial perfusion and metabolism and on coronary arteries calcification. Furthermore, by gated myocardial perfusion studies, PET may provide crucial information on regional coronary blood flow reserve and endothelial dysfunction. A number of recent papers provide some insight on the potential of PET/CT in cardiology and in the assessment of various cardiovascular diseases including various types of vasculitis and metabolic diseases.

2006-05-01

157

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

Energy Technology Data Exchange (ETDEWEB)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-08-01

158

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

International Nuclear Information System (INIS)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-01-01

159

Imaging Automation and Volume Tomographic Visualization at Texas Neutron Imaging Facility  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has been developed at the University of Texas reactor. The facility produced good-quality radiographs and two-dimensional tomograms. Further developments have been recently accomplished. A computer software has been developed to automate and expedite the data acquisition and reconstruction processes. Volume tomographic visualization using Interactive Data Language (IDL) software has been demonstrated and will be further developed. Volume tomography provides the additional flexibility of producing slices of the object using software and thus avoids redoing the measurements.

1999-11-14

160

Computed tomography of hilar cholangiocarcinoma: a new sign  

International Nuclear Information System (INIS)

Thirty-seven patients with histologic proof of cholangiocarcinoma at the confluence were examined by computed tomography (CT) to determine whether this examination is of value in the assessment of these patients for surgery and whether there are any features specific to this type of tumor. Thirty-two patients showed intrahepatic duct dilatation; six of these showed dilatation of ducts in one lobe only. Eighteen patients had intrahepatic low-attenuation areas, while eight had a mass lesion in the porta hepatis. The results of this study show that CT provides useful anatomic information preoperatively but that the appearances are nonspecific. Lobar atrophy is highly suggestive of hilar cholangiocarcinoma, either of long-standing or with unilateral portal venous involvement.

1986-04-14

161

Computed tomography in the evaluation of soft tissue tumors  

International Nuclear Information System (INIS)

In order to evaluate the role of Computed Tomography (CT) in prediction of nature, staging and follow-up of soft-tessue tumors, the authors examined by CT 124 patients with soft tissue neoplasms who later underwent surgery (116 cases) or fine needle biopsy (8 cases). Comparison between CT and surgical or anatomical results showed that CT was able to correctly predict the benignancy or malignancy of the masses in 76% of cases but it was very seldom able to allow an hystological prediction. On the contrary CT was found to be a very useful tool for pre-therapeutic staging and follow-up of the tumors, because it gave many diagnostic information which influenced therapeutic choiches and strategies.

1986-01-01

162

Computed tomography in the evaluation of 41 cases of Ewing's sarcoma  

International Nuclear Information System (INIS)

Computed tomography (CT) has already proved extremely effective both in cerebral and abdominal pathology. Several recent publications describing first heterogeneous series [1, 2, 7, 11-17], then studies of a single type of lesion [3-6, 8] have illustrated its usefulness in the study of bone lesions. This report deals with 41 cases of Ewing's sarcoma studied by CT at the Institut Gustave Roussy from October 1977 to July 1981, and tries to show both the limitations and indications of this technique for the diagnosis, treatment, and follow-up of Ewing's sarcoma as well as in the diagnosis of any eventual recurrence. (orig.).

163

Computed tomography in spinal osteoblastoma  

International Nuclear Information System (INIS)

In order to stress the role of computed tomography (CT) in the evaluation of benign spinal osteoblastoma, the authors examined by CT 10 patients with surgically and histologically proved osteoblastomas of the spine. Basing on surgical and histopathological findings CT proved to be a very important method for attesting the presence of the tumors (usually showed by radiographic examination), and specially for their staging and follow-up. CT in fact showed the real extent of the tumor into the spinal canal and towards the paraspinal soft tissues, and allowed the aerly detection of post surgical relapses. The authors conclude that CT is a primary diagnostic modality for preoperative planning and follow-up of benign osteoblastoma.

1986-01-01

164

Application of the neutron television fluoroscopic system to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).

1984-10-01

165

Application of the neutron television fluoroscopic system to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter.

1984-10-01

166

An application of the neutron television fluoroscopic system to neutron computed tomography  

International Nuclear Information System (INIS)

Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).

1984-10-01

167

High-Resolution Computed Tomography with Single-Slice Computed Tomography and 16-Channel Multidetector Computed Tomography: A Comparison Regarding Visibility and Motion Artifacts  

International Nuclear Information System (INIS)

Background: High-resolution computed tomography is the image procedure of choice in the evaluation of interstitial lung disease. Multidetector-row computed tomography provides the possibility of simultaneous reconstruction of thin and thick slices from the same raw data, acquired from one single series. Thus, it may be tempting to exclude the step-and-shoot series. Purpose: To compare high-resolution computed tomography (HRCT step-and-shoot) from single-slice CT (SSCT) and 16-channel multidetector CT (MDCT) in terms of visibility and motion artifacts, and to investigate whether thin images reconstructed from helical MDCT are equal to or better than conventional HRCT by SSCT in terms of visibility and motion artifacts. Material and Methods: 20 patients underwent HRCT step-and-shoot by SSCT (SSCT step-and-shoot) and MDCT (MDCT step-and-shoot), and a helical MDCT acquisition (MDCT helical). Images from four anatomical levels ...

2007-11-01

168

Consistency of ocular coherence tomography fast macular thickness mapping in diabetic diffuse macular edema  

Energy Technology Data Exchange (ETDEWEB)

Objectives: To investigate optical coherence tomography consistency on foveal thickness, foveal volume, and macular volume measurements in patients with and without diffuse diabetic macular edema. Introduction: Optical coherence tomography represents an objective technique that provides cross-sectional tomographs of retinal structure in vivo. However, it is expected that poor fixation ability, as seen in diabetic macular edema, could alter its results. Several authors have discussed the reproducibility of optical coherence tomography, but only a few have addressed the topic with respect to diabetic maculopathy. Methods: The study recruited diabetic patients without clinically evident retinopathy (control group) and with diffuse macular edema (case group). Only one eye of each patient was evaluated. Five consecutive fast macular scans were taken using Ocular Coherence Tomography 3; the 6 mm macular map ...

2007-07-01

169

What can we learn about extragalactic radio jets from X-ray data?  

CERN Document Server

We review the current status of resolved X-ray emission associated with extragalactic radio jets and hotspots. The primary question for any particular jet is to decide if the X-rays come from the synchrotron process or from inverse Compton scattering. There is considerable evidence supporting synchrotron emission for knots in the jets of FRI galaxies. For FRII terminal hotspots detected in the X-ray band, synchrotron self-Compton emission continues to provide viable models with one possible exception (so far). Inverse Compton scattering on photons of the cosmic microwave background is indicated for a few powerful jets, and is expected to be an important contributor if not the dominating mechanism for higher redshift objects. The application of a model generally yields physical parameters and in many cases, these include the Doppler boosting factor.

2003-01-01

170

The radio jet in NGC 6251  

International Nuclear Information System (INIS)

High-resolution observations are presented of the 300-kpc jet in the giant radio galaxy NGC 6251. The width of the jet is resolved over most of its length, and the axis of the jet wiggles with an amplitude increasing linearly with distance from the nucleus. Polarization data are used to derive densities of cold matter in the jet and, from the argument that the jet must form the lobe in a time equal to the age of the lobe, the speed of the jet is estimated as c/20. The energetics of the jet are then dominated by the bulk flow along it of cold matter at a rate of 1 solar mass yr"-"1. The jet appears to be confined; the wiggle of its axis is probably due to oscillations of the direction of the collimator with a period of about 6 x 10"6 yr. (author).

171

The X-ray Halo of G21.5-0.9  

CERN Document Server

The emission of the plerion G21.5-0.9 appears more extended in X rays than in radio. This is an unexpected result because it would imply that short-lived X-ray electrons may reach distances even larger than radio electrons. Applying an empirical relationship between dust scattering optical depth and photoelectric column density, the measured column density leads to a large optical depth at 1 keV, of about 1. Therefore we investigate the hypothesis that the detected halo be an effect of dust scattering, re-analyzing an Cal/PV XMM-Newton observation of G21.5-0.9 and critically examining it in terms of a dust scattering model. We also present a spectral analysis of a prominent extended feature in the northern sector of the halo.

2003-01-01

172

TUNABLE FIBER FABRY-PEROT FILTER FOR OPTICAL CARRIER-SUPPRESSION AND SINGLE-SIDEBAND MODULATION IN RADIO OVER FIBER LINKS  

British Library Electronic Table of Contents (United Kingdom)

A novel method of simultaneous realization of optical carrier-suppression and single-sideband modulation using fiber Fabry-Perot tunable filter is presented. In order to enhance transmission performance of radio over fiber links, we use a fiber Fabry-Perot tunable filter to filter out one sideband as well as suppress the optical carrier power. The results demonstrate 20.5dB and 14.2dB improvement in the signal noise ratios when 18GHz and 10GHz microwave signals carrying 5Mbit/s quadrature-phase-shift-keyed (QPSK) format data is transmitted over 35 km single mode fiber, respectively.

2006-01-01

173

THE RADIO JET INTERACTION IN NGC 5929: DIRECT DETECTION OF SHOCKED GAS  

International Nuclear Information System (INIS)

We report on the discovery of kinematic shock signatures associated with a localized radio jet interaction in the merging Seyfert galaxy NGC 5929. We explore the velocity-dependent ionization structure of the gas and find that low-ionization gas at the interaction site is significantly more disturbed than high-ionization gas, which we attribute to a local enhancement of shock ionization due to the influence of the jet. The characteristic width of the broad low-ionization emission is consistent with shock velocities predicted from the ionization conditions of the gas. We interpret the relative prominence of shocks to the high density of gas in the nuclear environment of the galaxy and place some constraints of their importance as feedback mechanisms in Seyferts.

2010-03-10

174

Solar-Geophysical Data Number 568, December 1991. Part 1 (prompt reports). Data for November, October 1991 and late data  

Energy Technology Data Exchange (ETDEWEB)

The contents include: Detailed index for 1991; Data for November 1991--Solar-terrestrial environment, IUWDS alert periods (advance and worldwide), Solar activity indices, Solar flares, Solar radio emission, Stanford mean solar magnetic field; Data for October 1991--Solar active regions, Sudden ionospheric disturbances, Solar radio spectral observations, Cosmic ray measurements by neutron monitor, Geomagnetic indices; Late data--Cosmic ray measurements by neutron monitor (Climax February and May 1990, Deep River May-August 1991), Geomagnetic indices (Sudden commencements/Solar flare effects January-May 1991); Errata--August 1991 Geomagnetic activity indices.

1991-12-01

175

Radio nuclear aggression. Psychological impact and management; L'agression radio-nucleaire. Impact psychologique et prise en charge  

Energy Technology Data Exchange (ETDEWEB)

Long before possible organic effects, exposure to ionizing radiations can provoke anxiety. In front of invisibility, the imagination quickly ignites. The terrorists have perfectly understood it. They are ready to use ionizing radiations as a weapon to remind traumatic images deeply rooted in people's memory. These images induce anxiety with all the clinical expressions connected to it. These symptoms require to be treated because of a possible anarchic development. For that purpose, plans have been elaborated to coordinate the different professional's actions. The coherence of medical management and communication aims to allow the most implicated people to find the way to face the events. When it is not possible, medico-psychological cells permit a specialized care. (author)

2006-08-15

176

Radio frequency plasma nitriding of aluminium at higher power levels  

International Nuclear Information System (INIS)

Nitriding of aluminium 2011 using a radio frequency plasma at higher power levels (500 and 700 W) and lower substrate temperature (500 deg. C) resulted in higher AlN/Al_2O_3 ratios than obtained at 100 W and 575 deg. C. AlN/Al_2O_3 ratios derived from X-ray photoelectron spectroscopic analysis (and corroborated by heavy ion elastic recoil time of flight spectrometry) for treatments preformed at 100 (575 deg. C), 500 (500 deg. C) and 700 W (500 deg. C) were 1.0, 1.5 and 3.3, respectively. Scanning electron microscopy revealed that plasma nitrided surfaces obtained at higher power levels exhibited much finer nodular morphology than obtained at 100 W.

2006-12-05

177

Quasi-stationary and transient patterns in jets  

Science.gov (United States)

Apparent evolution of relativistic flows as traced by radio emission results from a combination of several factors related to propagation of relativistic blobs or shocks, velocity, density and pressure stratification of the underlying flow, plasma instability and (possibly also) phase and time travel effect. This combination can create an intricate and chaotic patterns of the observed morphological changes in radio emission, which complicates the analysis and interpretation of kinematic and physical properties of the jet plasma. Recent studies have indicated that slow and quasi-stationary patterns in jets are most likely formed by plasma instabilities while faster, superluminally moving patterns are related to highly relativistic plasma condensations produced by the nuclear flares. Some of the stationary patterns may also be related to recollimation shocks or locations where strong non-thermal continuum is produced in jets. Similarities and ...

2011-01-01

178

Passivation of uranium metal by radio-frequency plasma nitriding against gas phase (H{sub 2}, H{sub 2}O) corrosion  

Energy Technology Data Exchange (ETDEWEB)

Thin passive layers of uranium nitride were formed by nitriding pure metallic uranium in non-equilibrium, low pressure radio-frequency plasma of nitrogen. Plasma nitriding at low substrate temperature of 230 C-250 C was found to cause the formation of adherent layers of uranium sesquinitride ({alpha}-U{sub 2}N{sub 3}) which provide a considerable protection against hydrogen attack. The characteristics of these passivation layers were determined by X-ray diffraction and Auger electron spectroscopy. The incipient hydriding kinetics of the plasma-treated samples were compared with those of untreated and nitrogen-ion implantation ones, utilizing a hot-stage microscope that was monitored continuously with a TV camera and videotape. (orig.)

1996-07-01

179

An evaluation of the embedment of a Radio Frequency Integrated Circuit with a temperature detector in building envelopes for energy conservation  

British Library Electronic Table of Contents (United Kingdom)

Concrete is the primary material for building envelopes in some parts of the world, and its ability to store heat as well as its dynamic temperature changes will not only affect the deterioration rate of the exterior wall but will also greatly influence the energy efficiency of interior air conditioning. There are many methods for measuring the inner temperature of concrete, but they often have limitations, such as indirect estimation, cable installation requirements, high cost, or heterogeneity of the sample structure. In order to measure the internal temperature of concrete, this study integrated a Radio Frequency Integrated Circuit (RFIC) with a temperature sensor chip and embedded the device in concrete structures. A Smart Temperature Information Material (STIM) was thus developed. Thi...

2011-01-01

180

A MAC protocol for cognitive wireless sensor body area networking  

British Library Electronic Table of Contents (United Kingdom)

Abstract In this paper, a Cognitive Radio Based Medium Access Control (CR-MAC) protocol for Wireless Sensor Body Area Networks (WSBAN) that utilizes cognitive radio transmission is proposed. In this proposal, the sensor nodes are classified into nodes of life-critical health information and nodes of non-critical health information. The CR-MAC protocol prioritizes the critical packets access to the transmission medium by transmitting them with higher power while transmitting lower priority packets using lower transmission power. At the receiver, a higher priority packet experiences collision only when there are more than one critical packet transmission at the same transmission slot while non critical packets experience collision when there are more than one transmission at the same transmi...

2010-01-01

181

The Performance Evaluation of a Hot Water Layer using a Numerical Simulation  

International Nuclear Information System (INIS)

Most of all research reactors are immerged in the deep water pool to be a ultimate heat sink. At the neighbor of the reactor, some radio-active matters, such as Na-24, Ar-41, Mg-27, Al-28 and etc, may be generated by the neutron irradiation. Those radio-active isotopes may rise up to the pool water surface through the natural convection flow, which can make the radioactivity in the reactor hall rise high enough to concern about the health of people working in the reactor hall. When the irradiation test facilities are loaded or unloaded during a normal operation, the highly radio-activated primary coolant may flow out through the irradiation test holes on the top of the reactor. This also may be a main hazard source to make the working environment of the reactor hall bad. Making a hot water layer 1.5 ? 2.0 m thick at the top of reactor pool would be a good measure to resolve that problem. The hot water layer is formed by a ...

2009-05-01

182

Telephone communications on a face with two steep machine tracks - tests with the mobile X-phone  

Energy Technology Data Exchange (ETDEWEB)

The author gives an account of tests with the X-phone system. The aim of the tests was to establish the reliability and behaviour of the apparatus mounted on a winning machine and to investigate the possibility of setting up a radio link, without laying an extra wire, between the foot of the tubbing-lined roadway and the winning machine on a steep face. The author describes the face and the test conditions and presents details of the satisfactory test results.

1981-11-01

183

Spin evolution in wind-fed X-ray binaries  

International Nuclear Information System (INIS)

Global angular momentum balance suggests that the neutron stars in Be/X-ray binaries are not spinning in equilibrium. This requires an X-ray lifetime ''approx <'' 10"5 yr, and suggests that there are many 'dead' Be/X-ray binaries in the Galaxy. Some of these may be turned up as millisecond radio pulsars with Be star companions. (author).

184

Solar effects on communications  

International Nuclear Information System (INIS)

This paper focuses on potential effects of solar phenomena on communication systems used by the electric utility industry. It begins with a discussion of solar phenomena fundamentals and discussion of the interaction between solar emissions and the earth's ionosphere and magnetosphere. It continues with a discussion of the resulting impacts on communication systems including radio, satellite, wireline, fiber optic, and powerline systems and concludes with a discussion of mitigation techniques and a call for observers to report suspected solar impact experiencexperiences.

185

Report on the special program 78 satellite geodesy of the technical university of Munich  

Energy Technology Data Exchange (ETDEWEB)

Various topics include: (1) direction finding, (2) range finding, (3) Doppler measurements, (4) construction of a receiver for radio interferometry, (5) mobile laser range finding system, (6) figure-and field parameter determination/geopotential, (7) dynamics of the Earth-Moon system, and (8) kinematics of geodetic point fields.

1981-01-01

186

RF and microwave energy hots up  

Energy Technology Data Exchange (ETDEWEB)

The advantages of radiofrequency and microwaves, such as volumetric heating, rapid and selective heating, compactness of equipment and ease of operation, offer sound economic alternative heating techniques. This article discusses dielectric loss, its quantification, and how it is put to effective use, including the use of applicators. Brief recommendations are presented for whether to select radio frequency or microwaves for a particular application. Uses of radiofrequency and microwaves in the industrial, domestic and medical sectors are described.

1988-05-12

187

NAI: Year 4 Annual Report - NASA Astrobiology Institute  

Science.gov (United States)

His talk was based on the suggestion that life on Earh has been a long but accelerating ..... a New Class of Submarine Hydrothermal System"; April 29, 2002 , ..... of media personnel, including radio, television, newspapers, and magazines. ...... "The Birth of Stars and Planets" (Denver Museum of Nature and Science ...

188

Microwaves action applied to chemical reactions and processes; L`azione delle microonde nelle reazioni e nei processi chimici  

Energy Technology Data Exchange (ETDEWEB)

Microwaves improve the rate of many chemical reactions either interacting with the solvent, when the reaction is carried out in solution, or with the surface of a solid substrate where a suitable reagent is dispersed (dry chemistry). A few examples of chemical reactions positively affected by microwaves are described: particularly interesting are those concerning polymers and radio-pharmaceuticals.

1997-03-01

189

Microwaves - the hidden danger. Mikrowellen - die verheimlichte Gefahr  

Energy Technology Data Exchange (ETDEWEB)

Today, highly frequent radio waves are regarded as undangerous to man. Diseases seen at radar-technicians during the 2nd World War, however, indicated that microwaves applied in radar systems were hazardous to health. The Russian work medicine has been knowing microwave-caused hazards in industry since the beginning of the thirties. Therefore in some East-European countries there are terms of protection and severe norms of safety for the staying of persons in the radiation sphere of microwaves.

1987-01-01

190

Hyperfine interactions in HCOOD and DCOOH molecules  

Energy Technology Data Exchange (ETDEWEB)

The method of double microwave--radio-frequency resonance has been used to obtain spectra of the 2/sub 11/reverse arrow2/sub 12/ and 3/sub 21/reverse arrow3/sub 22/ transitions in HCOOD, DCOOH, and HCOOH molecules. The constants of the quadrupole bond of the deuterons have been determined, magnetic interactions being taken into acocunt. A comparison with results of previous studies is given.

1986-05-01

191

Heat Shock Protein 27-Targeted Heptapeptide of the PKC? Catalytic V5 Region Sensitizes Tumors With Radio- and Chemoresistance  

International Nuclear Information System (INIS)

Purpose: Previous data suggest that the PKC? catalytic V5 (PKC?-V5) heptapeptide (HEPT) (FEQFLDI) binds HSP27 and blocks HSP27-mediated radio- or chemoresistance. Here we investigated further the in vivo function of the PKC?-V5 HEPT. Methods and Materials: Labeling of HEPT with Cy5.5 or fluorescein isothiocyanate was performed to evaluate in vitro or in vivo distribution of HEPT. A clonogenic survival assay, flow cytometry, and Western blotting of cleaved caspase-3 were performed to determine in vitro sensitization effects of HEPT plus ionizing radiation (IR) versus IR alone or those of HEPT plus cisplatin(Cis) versus Cis alone. A nude mouse xenografting system was also applied to detect in vivo sensitizing effects of HEPT. Results: HEPT efficiently bound to HSP27 and showed sensitization after combined treatment with IR versus treatment with Cis alone in NCI-H1299 lung carcinoma cells, with higher HSP27 expression, which was similar to that of combined treatment ...

2011-05-01

192

GPRS Requirements. Dutch Smart Meter Requirements. Version 3.0. Final Status  

Energy Technology Data Exchange (ETDEWEB)

This document defines the requirements for the GPRS (General Packet Radio Service) infrastructure as part of the Dutch Smart Meter Specification. In this document all requirements originating from the NTA 8130, or additionally surveyed by a delegation of the Dutch grid operators, are presented in tables. Each requirement is tightly connected to one or more business use cases presented in the document. The ultimate goal of this procedure is to reduce ambiguity of the requirements due to a better understanding of the requirements.

2010-03-15

193

Enabling Technologies for Petascale Electromagnetic Accelerator Simulation  

Energy Technology Data Exchange (ETDEWEB)

The SciDAC2 accelerator project at SLAC aims to simulate an entire three-cryomodule radio frequency (RF) unit of the International Linear Collider (ILC) main Linac. Petascale computing resources supported by advances in Applied Mathematics (AM) and Computer Science (CS) and INCITE Program are essential to enable such very large-scale electromagnetic accelerator simulations required by the ILC Global Design Effort. This poster presents the recent advances and achievements in the areas of CS/AM through collaborations.

2007-11-09

194

Device for the inspection of curved pipes in steam raising units  

Energy Technology Data Exchange (ETDEWEB)

The chain of eddy current probes and a film cassette probe, which responds to radiation from a radio-active source in one of the heat exchanger pipes is examined. The probes are moved by nylon pipes on both ends of the chain through the pipe to be examined. The nylon pipes are bent off load. In this way the probes on the chain will adjust near to the plane of bending of the pipes to be tested.

1980-01-03

195

Carcinogenesis of inhaled radio daughters with uranium ore dust in beagle dogs  

International Nuclear Information System (INIS)

Daily exposures of adult beagle dogs to inhaled radon daughters and to uranium ore dust for 4-1/2 to 6 yr have produced respiratory tract carcinomas, at similar cumulative working level months (WLM) of exposures to those which induced carcinomas in uranium miners. Biological data from the beagle-dog experiments can therefore be used for prediction of carcinogenic risk under changing exposure conditions in future uranium miners.

1977-05-01

196

CRC handbook of biological effects of electromagnetic fields  

Energy Technology Data Exchange (ETDEWEB)

This book presents the current knowledge about the effects of electromagnetic fields on living matter. The three-part format covers dielectric permittivity and electrical conductivity of biological materials; effects of direct current and low frequency fields; and effects of radio frequency (including microwave) fields. The parts are designed to be consulted independently or in sequence, depending upon the needs of the reader. Useful appendixes on measurement units and safety standards are also included.

1986-01-01

197

Active RF filter for high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

A new technique is described in this paper for a general active radio frequency (RF) filter trap that can be used for suppressing noise or interference on high voltage (HV) transmission lines. The technique exploits the Miller effect of an RF amplifier in conjunction with a special sensing circuit, and is potentially far more economical to implement than conventional techniques that use passive HV filter components.

1993-07-01

198

Determination of anisotropic velocity model by reflection tomography of compression and shear modes; Determination de modele de vitesse anisotrope par tomographie de reflexion des modes de compression et de cisaillement  

Energy Technology Data Exchange (ETDEWEB)

As the jump from 2D to 3D, seismic exploration lives a new revolution with the use of converted PS waves. Indeed PS converted waves are proving their potential as a tool for imaging through gas; lithology discrimination; structural confirmation; and more. Nevertheless, processing converted shear data and in particular determining accurate P and S velocity models for depth imaging of these data is still a challenging problem, especially when the subsurface is anisotropic. To solve this velocity model determination problem we propose to use reflection travel time tomography. In a first step, we derive a new approximation of the exact phase velocity equation of the SV wave in anisotropic (TI) media. This new approximation is valid for non-weak anisotropy and is mathematically simpler to handle than the exact equation. Then, starting from an isotropic reflection tomography tool developed at Lt-'P, we extend the isotropic bending ray ...

2001-12-01

199

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial pilot studies with ...

2008-06-01

200

High resolution Computed Tomography in the study of temporal bone trauma  

International Nuclear Information System (INIS)

Thirty-five patients with temporal bone fractures were examined; the fractures were sometimes associated with dislocation of the assicular chain caused by road fatalities. Computed Tomography (CT) was performed either because of the presence of clinical symptoms associated with trauma of the temporal bone, because of a hemotympanum discovered during a CT scan of the brain. Thirty-three fractures were detected: 19 longitudinal, 6 transverse, and 8 complex. An incudostapedial dislocation was also detected, together with a displacement of a stapedial prosthesis from the lenticular process of incus, and 3 incus-malleus dislocation associated with fractures. High resolution CT allows the precise definition of the course of the fractures, of the associated dislocation of the ossicular chain, and of facial nerve lesion, thus allowing a more accurate surgical intervention. In the examination of the temporal bone, high resolution CT is preferible to pluridirectional ...

1988-01-01

201

Determination of the initial energy in computerized tomography with proton beams; Determinacao da energia inicial em tomografia computadorizada com feixe de protons  

Energy Technology Data Exchange (ETDEWEB)

In earliest works devoted to proton computed tomography it was shown that the advantage of pCT image reconstruction appears when the energy is close to the Bragg peak region, since the proton passes the object. This effect provided by the Bragg peak makes the computerized tomography with protons possible. However, when decreasing the initial proton energy, with the increase of the irradiation dose, there are two effects that work simultaneously in opposite ways. First, the energy loss of a proton in an object becomes bigger at small initial energy. At the same time decreasing of the proton energy results in the increase of the energy straggling, requiring a larger number of protons. In this work the radiation dose dependence on the proton initial energy was studied using analytical formulas and computer simulations. The investigation determined that the radiation dose practically does not depend on the initial energy, except in the energy ...

2007-07-01

202

Computed tomography of the thorax: a status report  

Energy Technology Data Exchange (ETDEWEB)

Computed tomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computed tomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. Future applications of CT include the staging of mediastinal ...

1981-11-01

203

Computed tomography of the thorax: a status report  

International Nuclear Information System (INIS)

Computed tomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computed tomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. Future applications of CT include the staging of mediastinal ...

204

Computed tomography of the orbit  

Energy Technology Data Exchange (ETDEWEB)

In less than a decade computed tomography (CT scanning) had a profound impact on diagnostic radiology. Radiology of the orbit is no exception. As early as 1973, reports published in the radiological literature indicated that this new noninvasive imaging method was a highly effective way of demonstrating intraorbital mass lesions. As CT scanners became widely available, computed tomography became a significant adjunct to ophthalmological diagnosis. Today the main indications for CT scanning of the orbit are: (1) suspected mass lesions, most frequently presenting as exophthalmos, (2) orbital trauma, including foreign bodies, (3) some congenital anomalies, and (4) suspicion of extension into the orbit of extraorbital disease processes. Along with ultrasonography, another new noninvasive imaging technique, CT has replaced a number of more invasive and often less effective diagnostic methods, such as orbital pneumography, venography, and ...

1981-01-01

205

Computed Tomography of the complications of prosthetic surgery of the abdominal aorta  

International Nuclear Information System (INIS)

Computerized Tomography has gained an important role in the diagnosis of the complications of prosthetic surgery of the abdominal aorta: the importance of such complications come from their frequency, which is proportional to the increasing number of interventions, and their severity. The authors investigated the CT patterns of the most frequent complications. 24 patients referred for strongly suspected postoperative complications were examined in 2 years: fever and leukocytosis (20 cases) and progressive anemia (4 cases) were the most frequent findings. The operation had been performed 7#+-# 12 weeks before (2 patients were excluded because surgery dated less than 3 weeks. 14 patients had infective complications: thickening (57%) and inhomogeneity (43%) of the periprosthetic wrap and ectopic gas bubble (78%) were the most frequent Computerized Tomography findings. The authors also observed 2 periprosthetic hematomas, 1 aneurysm relapse and 1 ...

1997-01-01

206

Clinical and tomographic aspects of macular microholes; Aspectos clinicos e tomograficos dos microburacos maculares  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To describe the clinical aspects and evaluate optical coherence tomography of macular microholes. Methods: Seven patients were assessed (8 eyes) with microholes of the macula. All patients underwent complete eye examination, fundus photography, fluorescent angiography and OCT-3 imaging. Results: Ages ranged from 26 to 69 years. Six patients were female (85.7%) and five of them had microhole in the right eye. The presenting symptom was decrease in visual acuity (71.3%) and central scotoma in (14.3%). Five eyes (71.4%) had no defects shown by fluorescent angiography. A defect in the outer retina was demonstrated in all eyes on optical coherence tomography. The lesions were nonprogressive. Conclusion: Macular microholes are small lamellar defects in the outer retina. The condition is nonprogressive, generally unilateral and compatible with good visual acuity. Fundus biomicroscopy associated with an optical coherence ...

2009-07-01

207

Use of surface affinity enrichment and cryo-embedding to prepare in vitro reconstituted mitotic chromosomes for EM tomography  

Energy Technology Data Exchange (ETDEWEB)

We present a novel preparation method for studies of in vitro reconstituted mitotic chromosomes from Xenopus laevis egg extracts. This method involves a gentle adsorption of chromosomes from the extracts using surface affinity enrichment, followed by plunge freezing, freeze-substitution and cryo-embedding before examination by EM tomography. For comparison, chromosomes were also prepared by a conventional method, which included immobilization of chromosomes in agarose and a room-temperature dehydration (embedding) protocol. Three-dimensional reconstructions showed that samples prepared with the new method have a greater interconnectivity of sub-structural features and a higher compaction ratio together with an apparently less perturbed chromatin structure than those prepared using the conventional approach. The implications of the new method for the preparation of other difficult samples and additional application possibilities are discussed.

2005-07-15

208

Three Dimensional Visualization for the Steam Injection into Water Pool using Electrical Resistance Tomography  

International Nuclear Information System (INIS)

The direct injection of steam into a water pool is a method of heat transfer used in many process industries. The amount of research in this area however is limited to the nuclear industry, with applications relating to reactor cooling systems. Electrical resistance tomography (ERT), a low cost, non-invasive and which has high temporal resolution characteristics, can be used as a visualization tool for the resistivity distribution for the steam injection into water pool such as IRWST. In this paper, three dimensional resistivity distribution of the process is obtained through ERT using iterative Gauss-Newton method. Numerical experiments are performed by assuming different resistive objects in the water pool. Numerical results show that ERT is successful in estimating the resistivity distribution for the injection of steam in the water pool

2010-10-01

209

Synthesis of C-11 iodoantipyrine for positron emission tomography  

Energy Technology Data Exchange (ETDEWEB)

We have developed a method for the synthesis of C-11 iodoantipyrine. Carbon-11-labeled methyl iodide, prepared from /sup 11/CO2, was used to methylate 3-methyl-1-phenyl-2-pyrazolin-5-one to form C-11 antipyrine. Following silica-gel column chromatography and iodination, radiochemical purity of the C-11 iodoantipyrine was more than 99.5%, with a 10% yield and a specific activity of 30 mCi/mumol. Preliminary animal studies showed complete cerebral extraction and local cerebral blood-flow values that were within 4.6% of those obtained using C-14 iodoantipyrine. The C-11 analog, with positron emission tomography, will facilitate local cerebral blood-flow studies in human subjects.

1981-06-01

210

Sialography, echography and computed tomography in parotid gland study  

International Nuclear Information System (INIS)

The diagnostic accuracy of sialography and ultrasonography (US) in the evaluation of parotid masses is evaluated. Furthermore the role of computed tomography (CT) in this pathology is discussed. In the personal experience US proved to be the best method in the recognition of a parotid tumor while sialography was superior in defining the intra or extraparotid site. The two investigations showed the same accuracy in the definition of benign or malignant nature of the mass. Therefore we consider US the only investigation in most istances; sialography could be performed when the site of the lesion is uncertain or an inflammatory lesion is suspected. CT is never the first investigation; its use is limited to a low number of cases, mainly for the evaluation of large masses and when the association US-sialography does not allow a sure diagnosis.

1985-01-01

211

Role of Computed Tomography in postoperative diskitis  

International Nuclear Information System (INIS)

Six patients with diskitis following lumbar disk surgery were investigated by Computed Tomography (CT). Four patients underwent CT in a rather early phase of the disease (5-37 days after the onset of the symptoms): a posterior paravertebral fluid collection was always recognized, while the plain film was normal. Later on (2-4 months), the classical signs of diskitis were evident, with both CT and the plain film. The collection was always present at CT. A reintervention, performed on 3 patients, revealed the purulent content of the collections. It seems reasonable to suggest a relationship between the collection and the subsequent diskitis; the collection is probably an early sign of the disease. Its detection is of grat value, because it could allow an immediate and adequate therapy. The authors stress the usefulness of performing CT in an early phase on this kind of symptomatic patients.

1988-01-01

212

Retroperitoneoscopic partial adrenalectomy for small adrenal tumours (<=1 cm): the Ruijin clinical experience in 88 patients  

British Library Electronic Table of Contents (United Kingdom)

Study Type - Therapy (case series)Level of Evidence 4 OBJECTIVE To present our experience of retroperitoneoscopic partial adrenalectomy (RPA) for small adrenal tumours, as with modern imaging methods small adrenal lesions are being diagnosed more commonly, and retroperitoneoscopic adrenal surgery for small adrenal tumours (PATIENTS AND METHODS We retrospectively reviewed the records of 389 consecutive retroperitoneoscopic adrenalectomies from September 2005 to December 2008, 88 of which were small adrenal tumours and treated by RPA. Ultrasonography and computed tomography (CT) were used in all patients before RPA, and magnetic resonance imaging or positron emission tomography/CT in some patients. We used RPA for adrenal tumours and total adrenalectomy for adrenal cancer. During the surgery...

2010-01-01

213

Radiopharmaceuticals labelled with positron emitting radionuclides  

International Nuclear Information System (INIS)

A brief survey is presented of the methods of preparation and of the applications of radiopharmaceuticals labelled with short-lived positron radionuclides "1"1C, "1"8F, "1"3N and "1"5O which, thanks to their energy level schemes, short half-life and the 511 keV photon radiation energy are almost ideal tracers in modern nuclear medicine and pharmacology. In conjunction with computerized tomography, they represent one of the most sensitive diagnostic imaging methods, the so-called positron emission tomography. In addition, their incorporation in the molecule of a pharmaceutical does not change the biological and chemical properties of the original molecule unlike those of radiopharmaceuticals labelled with technetium, iodine, etc. (author). 125 refs.

1989-01-01

214

Quantitative Computed Tomography (QCT) of vertebral spongiosa. Evaluation of a possible method for managment of postmenopausal osteoporosis (PMO)  

International Nuclear Information System (INIS)

A Quantitative Computed Tomography (QCT) method, simplifying the well-known technique proposed by Genant (1982) and applied to a standard third generation whole body CT scanner is described. This technique was applied in the measurement of the trabecular bone which has high sensitivity for metabolic changes. The BMC (Bone Mineral Content) measured in different groups of subjects (healthy postmenopausal patients versus women with postmenopausal osteoporosis) showed a highly significant difference (p<0.001). The precision of repositioning (coefficient of variation 1.8% to 2.3%, obtained in healty male patients) and the good, linear relationship computed from the phantom values, minimize measurement errors. Since this method is quickly applied and involves low-dose radiation-exposure, it could be introduced in the clinical study of metabolic bone diseases.

1987-01-01

215

PET and MRI in cardiac imaging: from validation studies to integrated applications  

International Nuclear Information System (INIS)

Positron emission tomography (PET) is the gold standard for non-invasive assessment of myocardial viability and allows accurate detection of coronary artery disease by assessment of myocardial perfusion. Magnetic resonance imaging (MRI) provides high resolution anatomical images that allow accurate evaluation of ventricular structure and function together with detection of myocardial infarction. Potential hybrid PET/MR tomography may potentially facilitate the combination of information from these imaging modalities in cardiology. Furthermore, the combination of anatomical MRI images with the high sensitivity of PET for detecting molecular targets may extent the application of these modalities to the characterization of atherosclerotic plaques and to the evaluation of angiogenetic or stem cell therapies, for example. This article reviews studies using MRI and PET in parallel to compare their performance in cardiac applications together with the ...

2009-03-01

216

Nondestructive techniques for the control of conditioned radioactive wastes  

International Nuclear Information System (INIS)

The final product of the radwaste conditioning process must satisfy certain requirments and physico-chemical properties in order to assure its safe long-term behaviour. Of course, the foreseen quality assurance and quality control should be conducted by means of non-destructive techniques. This work presents an over-view of various applicable non-destructive methods of analysis, showing their fields of investigation in testing waste packages, together with some arising practical problems. The most promising methods, such as eddy current testing, ultrasonic testing, #gamma#-scanning, #gamma#-spectroscopy, neutron counting and computerized tomography, are treated more deeply and some applications are presented. Particular attention is devoted to the development of a device based on computerized tomography; its essential components are reported and some design problems are also discussed.

2005-09-01

217

New thermal neutron imaging facility at the University of Texas reactor  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed at the University of Texas TRIGA reactor. Extensive Monte Carlo design calculations were used to determine optimal design parameters of the neutron collimator system to avoid costly trial and error. Thermal neutron flux determined by gold foil activation is 5 {times} 10{sup 6} n/cm{sup 2}{center_dot}s at the primary imaging location with beam size of 22.5 cm in diameter. The collimation ratio can be varied from 125 to 235. The neutron-to-gamma ratio is 7.8 {times} 10{sup 6} n/cm{sup 2}{center_dot}mR. The facility has been tested for radiography and tomography applications and is now fully operational.

1999-09-01

218

Neutron imaging system for neutron tomography, radiography, and beam diagnostics  

Energy Technology Data Exchange (ETDEWEB)

A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.

1995-12-31

219

Multidetector Computed Tomography in the Preoperative Workup of Hilar Cholangiocarcinoma  

International Nuclear Information System (INIS)

Hilar cholangiocarcinoma is associated with a dismal prognosis; however, curative resection may offer a chance of cure. Various factors should be considered in the surgical planning for curative resection. These factors include extent of bile duct involvement, relationship between portal vein and tumor involvement, diffuse hepato duodenal ligament infiltration, vascular invasion, lymph node metastasis, peritoneal seeding, and hepatic volume. Using high-quality volume data from multidetector-row computed tomography (MDCT) and adequate postprocessing images, radiologists can provide various types of information, imperative for curative resection of a hilar cholangiocarcinoma. This review illustrates the role of MDCT in the preoperative workup of hilar cholangiocarcinoma.

2009-10-01

220

Low-dose contrast protocol using the test bolus technique for 64-detector computed tomography coronary angiography  

British Library Electronic Table of Contents (United Kingdom)

Purpose We evaluated low-contrast injection protocols for coronary computed tomography angiography (CTA) using a 64-detector scanner and the test bolus technique. Materials and methods We randomly assigned 60 patients undergoing coronary CTA to one of two contrast material (CM) injection protocols. For the lowcontrast dose protocol (Plow), the patients received injections of iohexol-350 [0.7 ml/kg body weight (BW)] during 9 s, and the test-bolus technique was used. Under the conventional protocol (Pconv), they received iohexol-350 (1.0 ml/kg BW) during 15 s, and bolus tracking was used. We compared the protocols for attenuation values in the ascending aorta and coronary arteries and for the amount of CM required. Results There was no significant difference in the mean CT attenuation of the...

2011-01-01

221

Importance of preoperative imaging with 64-row three-dimensional multidetector computed tomography for safer video-assisted thoracic surgery in lung cancer  

British Library Electronic Table of Contents (United Kingdom)

Purpose Video-assisted thoracic surgery (VATS) has recently been adopted for complicated anatomical lung resections. During these thoracoscopic procedures, surgeons view the operative field on a two-dimensional (2-D) video monitor and cannot palpate the organ directly, thus frequently encountering anatomical difficulties. This study aimed to estimate the usefulness of preoperative three-dimensional (3-D) imaging of thoracic organs. Methods We compared the preoperative 64-row three-dimensional multidetector computed tomography (3DMDCT) findings of lung cancer-affected thoracic organs to the operative findings. Results In comparison to the operative findings, the branches of pulmonary arteries, veins, and bronchi were well defined in the 3D-MDCT images of 27 patients. Conclusion 3D-MDCT imag...

2009-01-01

222

Impact of diagnosis by enhanced multidetector-row computed tomography and magnetic resonance imaging for extrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Herein we present an impact of diagnosis by enhanced multidetector-row computed tomography and magnetic resonance imaging for extrahepatic cholangiocarcinoma (ECC). Although the diagnosis against the longitudinal stromal extension and surrounding tissue invasion of ECC by multi detector row CT (MDCT) and MRI was very strict, we could not detect any superficial mucosal spread (SMS). Furthermore, the diagnosis of lymphnode metastasis by MDCT/MRI was miserable. We believe that misdiagnosis of SMS is permissible since positive mucosal but not stromal surgical margin was not a significant factor influencing the postoperative prognosis. However, further advances in imaging diagnosis for ECC is needed. (author)

2009-10-01

223

Imaging automation and volume tomographic visualization at Texas Neutron Imaging Facility  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has been developed at the University of Texas reactor. The facility produced a good-quality radiographs and two-dimensional tomograms. Further developments have been recently accomplished. Further developments have been recently accomplished. A computer software has been developed to automate and expedite the data acquisition and reconstruction processes. Volume tomographic visualization using Interactive Data Language (IDL) software has been demonstrated and will be further developed. Volume tomography provides the additional flexibility of producing slices of the object using software and thus avoids redoing the measurements.

1999-07-01

224

High-Resolution Optical Coherence Tomography Findings in Solar Maculopathy and the Differential Diagnosis of Outer Retinal Holes  

British Library Electronic Table of Contents (United Kingdom)

PurposeTo characterize the morphology of outer retinal holes caused by solar maculopathy, using spectral-domain optical coherence tomography (SD-OCT). DesignThis study is an observational case series. MethodsThe SD-OCT findings of 3 patients (6 eyes) with chronic solar maculopathy are presented. ResultsSD-OCT demonstrates a characteristic appearance of partial-thickness hole(s) in the outer retina at the fovea. In 3 of 6 eyes, there is 1 hole directly beneath the umbo. In the remaining 3 eyes, there are multifocal holes spread across the fovea. Holes in more restricted layers, as had been previously reported with time-domain OCT, were not seen. In addition, advanced visualization of SD-OCT data demonstrates a hyperreflective ring around the outer retinal hole. ConclusionsSD-OCT can be used...

2011-01-01

225

Development of Methods for Obtaining Position Image and Chemical Binding Information from Flow Experiments of Porous Media  

Energy Technology Data Exchange (ETDEWEB)

Existing oil reservoirs might be more fully exploited if the properties of the flow of oil and water in porous media were better known. In laboratory experiments it is important to collect as much information as possible to make a descriptive model of the system, including position imaging and chemical binding information. This thesis develops nuclear methods for obtaining position image and chemical binding information from flow experiments of porous media. A combined positron emission tomography and single photon emission computed tomography system to obtain position images, and a time-differential perturbed angular correlation system to obtain chemical binding information, have been built and thoroughly tested. 68 refs., 123 figs., 14 tabs.

1998-12-01

226

Computed tomography colonography: the future of colon cancer screening  

Energy Technology Data Exchange (ETDEWEB)

Colorectal cancer (CRC) is the most common cause of cancer death among Canadian non-smokers. Each year about 21,500 Canadians are diagnosed with CRC. Ninety percent of cases occur in people aged 50 years or older. An estimated 4,800 Canadian men and 4,100 Canadian women die each year from the disease. About 75% of all new CRC cases arise in people with no known risk factors. Computed tomography colonography (CTC), a cross-sectional imaging examination that permits complete structural examination of the colon, shows promise as a tool for CRC screening. This article reviews the rationale for CRC screening, currently recommended Canadian and American screening guidelines and screening tools, and current evidence supporting CTC as a CRC screening tool and its advantages over conventional screening methods. (author)

2008-10-15

227

Computed tomography colonography: the future of colon cancer screening  

International Nuclear Information System (INIS)

Colorectal cancer (CRC) is the most common cause of cancer death among Canadian non-smokers. Each year about 21,500 Canadians are diagnosed with CRC. Ninety percent of cases occur in people aged 50 years or older. An estimated 4,800 Canadian men and 4,100 Canadian women die each year from the disease. About 75% of all new CRC cases arise in people with no known risk factors. Computed tomography colonography (CTC), a cross-sectional imaging examination that permits complete structural examination of the colon, shows promise as a tool for CRC screening. This article reviews the rationale for CRC screening, currently recommended Canadian and American screening guidelines and screening tools, and current evidence supporting CTC as a CRC screening tool and its advantages over conventional screening methods. (author)

2008-10-01

228

Computed Tomography of the spine in multiple myeloma  

International Nuclear Information System (INIS)

Computed Tomography (CT) of the spine was performed on 17 patients with myeloma in order to assess the role of the technique in recognizing and evaluating the extent of the lesions. Myelomatous lesions followed two patterns at CT: first of all, multiple focal lesions, whose density is either solid, liquid, or fatty; second, an extensive pattern involving the spongiosa of the vertebra, including the posterior arch. CT detected more lesions than conventional radiology; furthermore, the extent of the lesions was much better demonstrated by CT. CT should thus be performed: a) in case of pain and/or neurological findings in negative radiological examinations; b) to evaluate the extent of myelomatous lesions (mainly in the spine); c) in solitary myeloma CT may be performed on different bone segments with clinical symptomatology but normal X-ray findings.

1988-01-01

229

Characteristic features of intracranial meningiomas on magnetic resonance tomography  

International Nuclear Information System (INIS)

Twenty-three patients with intracranial meningiomas were examined by means of magnetic resonance tomography (MRT). In 13 patients the paramagnetic contrast medium gadolinium DTPA was used. Meningiomas show only slight changes in signal intensity compared with brain in the spin-echo mode, the greatest contrast being found on photon density images (TR 1600 ms, TE 35 ms). In T1 images more than 50% of the patients showed a low signal margin between tumour and brain. Hyperostosis of the calvarium is easily recognised, but MRT is unreliable for showing tumour calcification. After intravenous injection of gadolinium DTPA, there was marked homogeneous uptake in the meningiomas. These signs are useful for the diagnosis of a meningioma by MRT. (orig.).

230

Cardiac transplantation. Value of computed tomography  

International Nuclear Information System (INIS)

In 9 over 12 patients who underwent cardiac transplantation computed tomography was performed. In 5 of them CT was obtained also before the surgical treatment. In all patients angio-CT technique was performed, while the ECG-gated technique was employed only before surgery. CT shows changes in morphology of both atria but over all of the right one, and rotation of the heart on the longitudinal axis. The conditions of the pericardium are particulary well demonstrated: in 5 cases pericardial effusion was observed, 3 times localized and 2 times diffuse. Only in 1 patient a small thrombus in the right atrium was demonstrated. CT allows the possibility to obtain simultaneously information on mediastinum, lung and pleura. Pleural effusion, pulmonary infections and mediastinal complications are easily demonstrated.

1986-01-01

231

Biomechanical properties of the femoral neck relative to osteosynthesis methods and bone mineral content assessed by computed tomography  

International Nuclear Information System (INIS)

Bone mineral content as determined by computerized tomography (CT) and mechanical strength on axial loading were compared in 36 cadaveric femur specimens. Based on the CT measurements of density and area, the mass of a transverse slice of the femur was estimated. Highly significant correlations were demonstrated between strength and cancellous bone density. Even higher correlations were revealed when the bone masses of the proximal and distal femoral areas were calculated. Based on these findings, an equal distribution of the effective mass of the femur was postulated. This hypothesis was confirmed in an experimental rotational model. The CT attenuation values were also correlated to direct measurements of bone mineral content, i.e. calcium. Moreover, the strength of different metal implants, commonly used in femoral neck fractures, were assessed in cadaver specimens. 134 refs., 13 figs., 12 tabs.

232

Application of digital radiography to diagnosis of laryngeal diseases  

International Nuclear Information System (INIS)

Fuji Computed Radiography (FCR) is a new system of digital radiography that is based on the latest computer technologies. We applied this FCR system to the X-ray diagnosis of the laryngeal disease. Twenty patients with various laryngeal diseases were evaluated by both FCR frontal tomography and conventional screen-film frontal tomography under the same exposure condition. Both tomograms were then compared on the subject of the clarity of delineation of laryngeal structures. As the result, FCR tomograms revealed the feature of the laryngeal lumen and cartilages more clearly than conventional tomograms. In addition, energy subtraction method, which is one of FCR image processing systems, was presented as a new technical procedure to extinguish cervical spine shadows in plain anteroposterior laryngeal X-photograph. We stress that FCR system is the suitable procedure for X-ray analysis of laryngeal diseases, especially in the region related with ...

1986-01-01

233

An effective method to estimate multidimensional Gaussian states  

CERN Document Server

A simple and efficient method for characterization of multidimensional Gaussian states is suggested and experimentally demonstrated. Our scheme shows analogies with tomography of finite dimensional quantum states, with the covariance matrix playing the role of the density matrix and homodyne detection providing Stern-Gerlach-like projections. The major difference stems from a different character of relevant noises: while the statistics of Stern-Gerlach-like measurements is governed by binomial statistics, the detection of quadrature variances correspond to chi-square statistics. For Gaussian and near Gaussian states the suggested method provides, compared to standard tomography techniques, more stable and reliable reconstructions. In addition, by putting together reconstruction methods for Gaussian and arbitrary states, we obtain a tool to detect the non-Gaussian character of optical signals.

2009-01-01

234

Adenopathies in lung cancer: a comparison of pathology, Computed Tomography and endoscopic ultrasound findings  

International Nuclear Information System (INIS)

A prospective comparative study with pathology was performed to assess the clinical value of Computed Tomography (CT) and endoscopic ultrasound (EUS) for nodal staging in lung cancer. A total of 329 nodal stations were dissected or sampled and 755 lymph nodes were examined at histology. On a pre-station basis, CT had greater sensitivity (74%) than EUS (56%), but EUS was more specific (83% versus 93%). The accuracy rates of the two techniques were similar. In conclusion, endoscopic ultrasound should be part of a routine preoperative diagnostic approach to non-small-cell lung cancer., because of its high specificity. Results can be improved when EUS and CT are combined., which suggests that these imaging modalities should be used together in selected patients for the noninvasive staging of non-small-cell lung cancer to identify local lymphatic spread.

1999-01-01

235

A tomography system at the thermal neutron column of the ENEA Casaccia TRIGA reactor  

Energy Technology Data Exchange (ETDEWEB)

The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10{sup 6} n/cm{sup 2} s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)

2002-07-01

236

A tomography system at the thermal neutron column of the ENEA Casaccia TRIGA reactor  

International Nuclear Information System (INIS)

The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10"6 n/cm"2 s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)

237

A study of reconstruction algorithms and filters for an industrial X-ray tomography system  

Energy Technology Data Exchange (ETDEWEB)

Computed tomography (CT) has been incorporated in an industrial Diode-Array Digital Radiography (DADR) system. An input data size of 512 pixel points x 400 projections yielded a 400x400 output image matrix. Reconstruction algorithms used are the filtered backprojection (FBP) and the direct Fourier reconstruction (DFR). Various filters were used in the FBP reconstruction process and their effects on image quality were evaluated. A spatial resolution of 100 {mu}m was measured with a block of plates and a minimum detectable feature size in the range of 10-100 {mu}m was measured using thin wires. Industrial specimens imaged have included ceramic samples, ball bearings and integrated circuits. A number of engineering problems have been solved, such as adjustment of the X-ray source, centering of the rotator spindle in the view field and beam-hardening corrections. (orig.).

1990-12-20

238

Unification of Luminous Type 1 Quasars through CIV Emission  

CERN Document Server

Using a sample of 30,000 quasars from SDSS-DR7, we explore the range of properties exhibited by high-ionization, broad emission lines, such as CIV 1549. Specifically we investigate the anti-correlation between L_UV and emission line EQW (the Baldwin Effect) and the "blueshifting" of high-ionization emission lines. The blueshift of the CIV emission line is nearly ubiquitous, with a mean shift of 810 km/s for radio-quiet (RQ) quasars and 360 km/s for radio-loud (RL) quasars, and the Baldwin Effect is present in both RQ and RL samples. Composite spectra are constructed as a function of CIV emission line properties in attempt to reveal empirical relationships between different line species and the SED. Within a two-component disk+wind model of the broad emission line region (BELR), where the wind filters the continuum seen by the disk component, we find that RL quasars are consistent with being dominated by the disk component, while BALQSOs are ...

2010-01-01

239

The Distribution and Condition of the Warm Molecular Gas in Abell 2597 and Sersic 159-03  

CERN Document Server

We have used the SINFONI integral field spectrograph to map the near-infrared K-band emission lines of molecular and ionised hydrogen in the central regions of two cool core galaxy clusters, Abell 2597 and Sersic 159-03. Gas is detected out to 20 kpc from the nuclei of the brightest cluster galaxies and found to be distributed in clumps and filaments around it. The ionised and molecular gas phases trace each other closely in extent and dynamical state. Both gas phases show signs of interaction with the active nucleus. Within the nuclear regions the kinetic luminosity of this gas is found to be somewhat smaller than the current radio luminosity. Outside the nuclear region the gas has a low velocity dispersion and shows smooth velocity gradients. There is no strong correlation between the intensity of the molecular and ionised gas emission and either the radio or X-ray emission. The molecular gas in Abell 2597 and Sersic 159-03 is well described ...

2010-01-01

240

Surface modification of titanium by radio frequency plasma nitriding  

Energy Technology Data Exchange (ETDEWEB)

Radio frequency (RF) plasma nitriding using different input plasma processing powers (250-600 W) improves the surface of titanium by forming hard phases of TiN, Ti{sub 2}N, and Ti (N) into the surface. The characteristics of the compound layer have been investigated by optical microscopy, microhardness measurements, and X-ray diffraction. The effect of plasma power on the sample temperature, electron temperature, and plasma density was studied using Langmuir double probe. The measured surface hardness value of the compound layer is 2190 HV 0.1 for treated sample at plasma power 500 W. The compound thickness continuously increases as the plasma power increases. The highest nitriding rate of 5.88 {mu}m{sup 2}/s was recorded when the input plasma power was adjusted at 550 W. This high nitriding rate of treated titanium samples is ascribed to the high concentration of active nitrogen species in the plasma atmosphere and the formed microcracks near to the surface of the ...

2006-02-21

241

Surface modification of titanium by radio frequency plasma nitriding  

International Nuclear Information System (INIS)

Radio frequency (RF) plasma nitriding using different input plasma processing powers (250-600 W) improves the surface of titanium by forming hard phases of TiN, Ti_2N, and Ti (N) into the surface. The characteristics of the compound layer have been investigated by optical microscopy, microhardness measurements, and X-ray diffraction. The effect of plasma power on the sample temperature, electron temperature, and plasma density was studied using Langmuir double probe. The measured surface hardness value of the compound layer is 2190 HV 0.1 for treated sample at plasma power 500 W. The compound thickness continuously increases as the plasma power increases. The highest nitriding rate of 5.88 #mu#m"2/s was recorded when the input plasma power was adjusted at 550 W. This high nitriding rate of treated titanium samples is ascribed to the high concentration of active nitrogen species in the plasma atmosphere and the formed microcracks near to the surface of the sample ...

2006-02-21

242

Second mission of North-Cotentin radio-ecology group. The uncertainty calculation; Deuxieme mission du Groupe Radio-ecologie Nord-Cotentin. Le calcul d'incertitude  

Energy Technology Data Exchange (ETDEWEB)

The present study treats only the collective risk of ex-utero leukaemia associated with the routine releases of the nuclear industrial installations of the North Cotentin (0.0009 cases over the considered period) the uncertainty on the contribution to the collective risk of the incidents and the accidents of the nuclear installations (notably the drilling of the pipe of release in sea arisen in 1979-1980 and the fire of the waste silo on January 6. 1981, for the reprocessing plant of La Hague has not been considered. Only 45% of the risk are taken into account by the study. Every calculated value remains very inferior to the number of leukemia cases observed (4 cases observed for two expected cases) and to the risk of radioinduced leukemia any merged exposure sources, that is to say 0.84 cases. It appears thus not very probable that the nuclear installations of the North - Cotentin can explain the tendency to the excess of observed leukaemia. The limits of the study become attached for ...

2003-03-15

243

Radioiodinated peanut lecitin: A potential radiopharmaceutical for immunodetection of carcinoma expressing the T antigen  

International Nuclear Information System (INIS)

The Thomsen-Friedenreich (T) antigen, #betta#-D-Gal-(1->3)-#alpha#-D-GalNAc, is exposed in reactive form on many human adenocarcinomata, but not on corresponding benign tissues. Peanut lectin (PNA) has a strong binding affinity for the T antigen and reportedly binds preferentially to certain malignant tissues. We investigated the potential of radio-labelled PNA as a tumour localising agent in an animal model system using a mouse lymphoma (RI) shown to bind fluorescein-labelled PNA in vitro. The radio-iodinated lectin showed good tumour localisation and rapid blood clearance. Clear images of tumours were obtained, in serial scintigraphic imaging, by 24 and 48 h. No blood background subtraction was necessary. Biodistribution studies revealed tumour to blood ratios in mice were 6:1 (at 24 h) and 17:1 (at 48 h), and tumour to muscle ratios were 34:1 (at 24 h) and 40:1 (at 48 h). Rapid in vivo breakdown of _1_2_5I-PNA led to some localisation of ...

1983-01-01

244

Radio-frequency plasma nitriding and nitrogen plasma immersion ion implantation of Ti-6Al-4V alloy  

Energy Technology Data Exchange (ETDEWEB)

Nitrogen ion implantation improves the wear resistance of Ti-6Al-4V alloys by forming a hard TiN superficial passivation layer. However, the thickness of the layer formed by traditional ion implantation is typically 100-200 nm and may not be adequate for many industrial applications. We propose to use radio-frequency (RF) plasma nitriding and nitrogen plasma immersion ion implantation (PIII) to increase the layer thickness. By using a newly designed inductively coupled RF plasma source and applying a series of negative high voltage pulses to the Ti-6Al-4V samples. RF plasma nitriding and nitrogen PIII can be achieved. Our process yields a substantially thicker modified layer exhibiting more superior wear resistance characteristics, as demonstrated by data from micro-hardness testing, pin-on-disc wear testing, scanning electron microscopy (SEM), as well as Auger electron spectroscopy (AES). The performance of our newly developed inductively coupled RF plasma source ...

1997-09-01

245

Radio-frequency plasma nitriding and nitrogen plasma immersion ion implantation of Ti-6Al-4V alloy  

International Nuclear Information System (INIS)

Nitrogen ion implantation improves the wear resistance of Ti-6Al-4V alloys by forming a hard TiN superficial passivation layer. However, the thickness of the layer formed by traditional ion implantation is typically 100-200 nm and may not be adequate for many industrial applications. We propose to use radio-frequency (RF) plasma nitriding and nitrogen plasma immersion ion implantation (PIII) to increase the layer thickness. By using a newly designed inductively coupled RF plasma source and applying a series of negative high voltage pulses to the Ti-6Al-4V samples. RF plasma nitriding and nitrogen PIII can be achieved. Our process yields a substantially thicker modified layer exhibiting more superior wear resistance characteristics, as demonstrated by data from micro-hardness testing, pin-on-disc wear testing, scanning electron microscopy (SEM), as well as Auger electron spectroscopy (AES). The performance of our newly developed inductively coupled RF plasma source ...

1996-09-15

246

Radio Frequency Plasma Applications for Space Propulsion  

Energy Technology Data Exchange (ETDEWEB)

Recent developments in solid-state radio frequency (RF) power technologies allow for the practical consideration of RF heated plasmas for space propulsion. These technologies permit the use of any electrical power source, de-couple the power and propellant sources, and allow for the effcient use of both the propellant mass and power. Effcient use of the propellant is obtained by expelling the rocket exhaust at the highest possible velocity, which can be orders of magnitude higher than those achieved in chemical rockets. Handling the hot plasma exhaust requires the use of magnetic nozzles, and the basic physics of ion detachment from the magnetic eld is discussed. The plasma can be generated by RF using helicon waves to heat electrons. Further direct heating of the ions helps to reduce the line radiation losses, and the magnetic geometry is tailored to allow ion cyclotron resonance heating. RF eld and ion trajectory calculations are presented to give a reasonably ...

1999-09-13

247

Properties of ZnO thin films prepared by radio-frequency plasma beam assisted laser ablation  

International Nuclear Information System (INIS)

Zinc oxide thin films were obtained by laser ablation of a Zn target in oxygen reactive atmosphere, the oxygen being supplied either by a standard gas inlet valve or from a radio-frequency (rf) oxygen plasma. Pt-coated silicon and MgO were used as substrates. The influence of the deposition parameters as laser wavelength (266, 355, 1064 nm), laser fluence (1.5-20 J/cm2) and oxygen pressure (1-60 Pa) was studied. The influence of the rf plasma beam addition on the morphological proprieties of zinc oxide films was particularly investigated, simultaneously with several configurations of the direction of the ablation plasma, the rf plasma beam and the substrate. The obtained films, with thicknesses in the range of 50 nm to 1 ?m have been characterized by atomic force microscopy (AFM), X-ray diffraction (XRD), transmission electron microscopy (TEM).

2005-07-15

248

Photovoltaic Technologies Beyond the Horizon: Optical Rectenna Solar Cell, Final Report, 1 August 2001-30 September 2002  

Energy Technology Data Exchange (ETDEWEB)

ITN Energy Systems is developing next-generation solar cells based on the concepts of an optical rectenna. ITN's optical rectenna consists of two key elements: (1) an optical antenna to efficiently absorb the incident solar radiation, and (2) a high-frequency metal-insulator-metal (MIM) tunneling diode that rectifies the AC field across the antenna, providing DC power to an external load. The combination of a rectifying diode at the feedpoints of a receiving antenna is often referred to as a rectenna. Rectennas were originally proposed in the 1960s for power transmission by radio waves for remote powering of aircraft for surveillance or communications platforms. Conversion efficiencies greater than 85% have been demonstrated at radio frequencies (efficiency defined as DC power generated divided by RF power incident on the device). Later, concepts were proposed to extend the rectennas into the IR and optical region of the ...

2003-02-01

249

Orion's Bar: Physical Conditions across the Definitive H+ / H0 / H2 Interface  

CERN Document Server

Previous work has shown the Orion Bar to be an interface between ionized and molecular gas, viewed roughly edge on, which is excited by the light from the Trapezium cluster. Much of the emission from any star-forming region will originate from such interfaces, so the Bar serves as a foundation test of any emission model. Here we combine X-ray, optical, IR and radio data sets to derive emission spectra along the transition from H+ to H0 to H2 regions. We then reproduce the spectra of these layers with a simulation that simultaneously accounts for the detailed microphysics of the gas, the grains, and molecules, especially H2 and CO. The magnetic field, observed to be the dominant pressure in another region of the Orion Nebula, is treated as a free parameter, along with the density of cosmic rays. Our model successfully accounts for the optical, IR and radio observations across the Bar by including a significant magnetic pressure and also heating ...

2008-01-01

250

Measurements of radio propagation in rock salt for the detection of high-energy neutrinos  

CERN Document Server

We present measurements of the transmission of radio/microwave pulses through salt in the Cote Blanche salt mine operated by the North American Salt Company in St. Mary Parish, Louisiana. These results are from data taken in the southwestern region of the 1500 ft. (457 m) deep level of the mine on our third and most recent visit to the mine. We transmitted and received a fast, high-power, broadband pulse from within three vertical boreholes that were drilled to depths of 100 ft. (30 m) and 200 ft. below the 1500 ft. level using three different pairs of dipole antennas whose bandwidths span 125 to 900 MHz. By measuring the relative strength of the received pulses between boreholes with separations of 50 m and 169 m, we deduce the attenuation of the signal attributed to the salt medium. We fit the frequency dependence of the attenuation to a power law and find the best fit field attenuation lengths to be 93 \\pm 7 m at 150 MHz, 63 \\pm 3 m at 300 MHz, and 36 \\pm 2 m ...

2008-01-01

251

High-resolution beta imaging; L'imagerie beta haute resolution  

Energy Technology Data Exchange (ETDEWEB)

For many years, {beta} radioactivity has been used to label molecules and follow them in various biological processes. {beta} imaging is obtained by autoradiography. Classically made on films or on photographic emulsions, autoradiography is now supplanted by radio-imagers which are very performing. The phosphor-imager, {beta}-imager and {mu}-imager are the systems mainly used today and their operating principles and properties are compared. The great advantages of these imagers are: their rapidity to obtain results and their reliability for absolute quantification. All emitters ({beta}{sup -}, {beta}{sup -} -{gamma} and {beta}{sup +}) are detectable as well as the gamma emitters of nuclear medicine, by means of their low energy electrons ejected during y emission. Phosphor-imager is well suited to energetic tracers and large series of experiments. Real time radio-imagers ({beta}-imager and {mu}-imager) are preferred to verify experimental ...

2007-04-15

252

Evaluation of influence of fertilizers in radium concentration from tomato culture; Avaliacao da influencia dos fertilizantes nos teores de radio encontrados na cultura do tomate  

Energy Technology Data Exchange (ETDEWEB)

The fertilizer contribution to radio uptake by tomato plants was assessed. Tomato and soil samples from four different plantations were analyzed: two using organic fertilizer and two using phosphate fertilizer. The Ra concentrations in eight of the most used tomato fertilizers were determined. The concentration values ranged from 14 to 221 Bq/kg of Ra-226 and from 25 to 176 Bq/kg of Ra-228. Owing to the low Ra concentration and to the used fertilizer quantities, the fertilizers would not increase significantly the Ra soil concentration. However, the highest soil to plant concentration ratios were found in the plantations using phosphate fertilizers. This outcome pointed out the higher Ra availability in the phosphate fertilizer plantations than in the organic fertilizer plantations, showing a possible positive influence of phosphate fertilizers for the tomato Ra uptake. Due to the phosphate fertilizer used, the dose could increase from 0,05 Sv/year to 0,24 Sv/year. ...

2001-07-01

253

Electrical properties of ultra-thin oxynitrided layer using N{sub 2}O plasma in inductively coupled plasma chemical vapor deposition for non-volatile memory on glass  

Energy Technology Data Exchange (ETDEWEB)

In this work, the silicon oxynitride layer was studied as a tunneling layer for non-volatile memory application by fabricating low temperature polysilicon thin film transistors on glass. Silicon wafers were oxynitrided by only nitrous oxide plasma under different radio frequency powers and plasma treatment times. Plasma oxynitridation was performed in RF plasma using inductively coupled plasma chemical vapor deposition. The X-ray energy dispersive spectroscopy was employed to analyze the atomic concentration ratio of nitrogen/oxygen in oxynitride layer. The oxynitrided layer formed under radio frequency power of 150 W and substrate temperature of 623 K was found to contain the atomic concentration ratio of nitrogen/oxygen as high as 1.57. The advantage of high nitrogen concentration in silicon oxide layer formed by using nitrous oxide plasma was investigated by capacitance-voltage measurement. The analysis of capacitance-voltage characteristics ...

2007-06-04

254

Electrical properties of ultra-thin oxynitrided layer using N_2O plasma in inductively coupled plasma chemical vapor deposition for non-volatile memory on glass  

International Nuclear Information System (INIS)

In this work, the silicon oxynitride layer was studied as a tunneling layer for non-volatile memory application by fabricating low temperature polysilicon thin film transistors on glass. Silicon wafers were oxynitrided by only nitrous oxide plasma under different radio frequency powers and plasma treatment times. Plasma oxynitridation was performed in RF plasma using inductively coupled plasma chemical vapor deposition. The X-ray energy dispersive spectroscopy was employed to analyze the atomic concentration ratio of nitrogen/oxygen in oxynitride layer. The oxynitrided layer formed under radio frequency power of 150 W and substrate temperature of 623 K was found to contain the atomic concentration ratio of nitrogen/oxygen as high as 1.57. The advantage of high nitrogen concentration in silicon oxide layer formed by using nitrous oxide plasma was investigated by capacitance-voltage measurement. The analysis of capacitance-voltage characteristics ...

2007-06-04

255

Electric field measurement on time domain generated by corona on insulators on distribution systems  

Energy Technology Data Exchange (ETDEWEB)

Radio interference and TV interference are being a problem in urban and rural areas. This interference is generated by high voltage transmission lines as well as distribution lines. The radio noise can be produced by polluted or damaged insulators, and by metal parts of the distribution lines. The corona effect on the surface of the dielectric material produces high frequency electromagnetic fields during the ionization and during the recombination period. Fields of different intensity are produced by positive voltage and negative voltage. The insulator flashover (leaking current) also produces electromagnetic fields. A new technique to measure these fields was developed. This technique measures the radiated fields on time domain and on frequency domain. This permits us to characterize the radiated field and thus identify the type of the source. Several measurements were done varying the type of the RF generator, i.e., new insulator and broken ...

1996-12-31

256

Effect of gamma radiation on the survival of fungal and actinomycetal florae contaminating medicinal plants  

Energy Technology Data Exchange (ETDEWEB)

This study evaluates the effect of gamma radiation on the viability of fungi and actinomycetes that contaminate medicinal plants. The relationship between the total lipids of some fungi and actinomycetes and their sensitivity to gamma radiation is also investigated. The data reveal that the viable counts of these florae decrease approximately exponentially with the radiation dose, the effective dose for the elimination of these microorganisms being about 5 kGy for all the medicinal plants under study. Response of pure cultures of fungi and actinomycetes isolated from medicinal plants to increasing absorbed doses of gamma radiation indicate that an increase in radioresistance is in the following order: Streptomyces rimosus, Fusarium solani, Nocardia kuroishii. F. oxysporum, A. fumigatus, A. flavus, A. parasiticus and A. ochraceus. The total lipid contents of molds and actinomycetes have been reported to be increased by increasing the radio-resistance of ...

1997-01-01

257

Development of nanometer resolution C-Band radio frequency beam position monitors in the Final Focus Test Beam  

Energy Technology Data Exchange (ETDEWEB)

Using a 47 GeV electron beam, the Final Focus Test Beam (FFTB) produces vertical spot sizes around 70 nm. These small beam sizes introduce an excellent opportunity to develop and test high resolution Radio Frequency Beam Position Monitors (RF-BPMs). These BPMs are designed to measure pulse to pulse beam motion (jitter) at a theoretical resolution of approximately 1 nm. The beam induces a TM{sub 110} mode with an amplitude linearly proportional to its charge and displacement from the BPM's (cylindrical cavity) axis. The C-band (5,712 MHz) TM{sub 110} signal is processed and converted into beam position for use by the Stanford Linear Collider (SLC) control system. Presented are the experimental procedures, acquisition, and analysis of data demonstrating resolution of jitter near 25 nm. With the design of future e{sup +}e{sup -} linear colliders requiring spot sizes close to 3 nm, understanding and developing RF-BPMs will be essential in resolving and ...

1998-08-01

258

DETECTION OF AN X-RAY PULSATION FOR THE GAMMA-RAY PULSAR CENTERED IN CTA 1  

International Nuclear Information System (INIS)

We report the detection of X-ray pulsations with a period of ?315.87 ms from the 2009 XMM-Newton observation for the radio-quiet ?-ray pulsar, LAT PSR J0007+7303, centered in the supernova remnant CTA 1. The detected pulsed period is consistent with the ?-ray periodicity at the same epoch found with the Fermi Gamma-ray Space Telescope. The broader sinusoidal structure in the folded light curve of the X-ray emission is dissimilar to that of the ?-ray emission, and the phase of the peak is about 0.5 shifting from the peak in the ?-ray bands, indicating that the main component of the X-rays originates from different sites of the pulsar. We conclude that the main component of the X-ray pulsation is contributed by the thermal emission from the neutron star. Although with a significantly different characteristic age, PSR J0007+7303 is similar to Geminga in emission properties of X-rays and ?-rays; this makes PSR J0007+7303 the second radio-quiet ...

2010-12-10

259

Comparison of LaBr_3:Ce and NaI(Tl) Scintillators for Radio-Isotope Identification Devices  

International Nuclear Information System (INIS)

Lanthanum halide (LaBr_3:Ce) scintillators offer significantly better resolution (< 3% at 662 keV) relative to NaI(Tl) and have recently become commercially available in sizes large enough for the handheld, Radio-Isotope Identification Device (RIID) market. Drawbacks to lanthanum halide detectors, however, include internal radioactivity contributing to spectral counts, and a low-energy response which can cause detector resolution to be worse than that of NaI(Tl) below 100 keV. To study the potential of this new material for RIIDs we performed a series of measurements comparing a 1.5 x 1.5-inch LaBr_3:Ce detector with an Exploranium GR-135 RIID, which contains a 1.5 x 2.2-inch NaI(Tl) detector. Measurements were taken for short timeframes, as typifies RIID usage. Measurements included examples of naturally occurring radioactive material (NORM), typically found in cargo, and special nuclear materials. Some measurements were non-contact, involving short distances ...

2005-10-23

260

Calibrating Emission Lines as Quasar Bolometers  

CERN Document Server

Historically, emission lines have been considered a valuable tool for estimating the bolometric thermal luminosity of the accretion flow in AGN, $L_{bol}$. We study the reliability of this method by comparing line strengths to the optical/UV continuum luminosity of SDSS DR7 radio quiet quasars with $0.4radio loud quasars as an illustrative ...

2011-01-01

261

An optimization method for reference dose point of rectum in brachytherapy of gynecological neoplasms  

International Nuclear Information System (INIS)

Rectum reference dose points have a direct impact on the morbidity seen in gynecological intracavitaty radiotherapy. The aim of this study is to obtain less morbidity by marking rectum with radio opaque solution. Fourteen patients with gynecological cancer who underwent external radiotherapy received 15 Gray (Gy) intracavitary radiotherapy. During the internal radiotherapy planning, radio opaque solution has been administered into the rectum to observe it on lateral radiogram. Thus rectum reference dose point and five points were marked at sites nearest to the sources. Nucletron Planning system was used for obtaining three-dimensional planning. After therapy patients were followed at every three months. Median follow-up was 18 months. Most frequently observed morbidities were grade 1-2 rectitis and cystitis in six patients. As a result, more accurate rectum dose values and less factors causing dose changing can provide better results for ...

2002-05-01

262

Adaptive response of the chicken embryo to low doses of x-irradiation  

Energy Technology Data Exchange (ETDEWEB)

Chicken embryos were x-irradiated in ovo with 5-30 cGy (=priming dose) at the 13th-15th day of development. After 3-48 h, brain- and liver-cell suspensions were x-irradiated in vitro with (challenge) doses of 4-32 Gy. Significantly less radiation damage was observed when the radiation response was measured by scheduled DNA synthesis, nucleoid sedimentation and viscosity of alkaline cell lysates 12-36 h after the priming exposure. In vivo, pre-irradiation with 10 cGy enhanced regeneration as evidenced by the DNA content of chicken embryo brain and liver 24 h following a challenge dose of 4 Gy. From nucleoid sedimentation analyses in brain and liver cells immediately after irradiation with 16 Gy and after a 30-min repair period in the presence of aphidicolin, dideoxythymidine and 3-aminobenzamide or in the absence of these DNA repair inhibitors, it is concluded that a reduction of the initial radiation damage is the dominant mechanism of the ``radio-adaptive`` ...

1995-08-01

263

A sensitive submillimetre survey of Broad Absorption Line quasars  

CERN Document Server

Using the SCUBA bolometer array on the JCMT, we have carried out a submillimetre survey of Broad Absorption Line quasars (BALQs). The sample has been chosen to match, in redshift and optical luminosity, an existing benchmark 850um sample of radio-quiet quasars, allowing a direct comparison of the submm properties of BAL quasars relative to the parent radio-quiet population. We reach a submm limit 1.5mJy at 850um, allowing a more rigorous measure of the submm properties of BAL quasars than previous studies. Our submm photometry complements extensive observations at other wavelengths, in particular X-rays with Chandra and mid-infrared with Spitzer. To compare the 850um flux distribution of BALQs with that of the non-BAL quasar benchmark sample, we employ a suite of statistical methods, including survival analysis and a novel Bayesian derivation of the underlying flux distribution. Although there are no strong grounds for rejecting the null ...

2006-01-01

264

A microcontroller-based data-acquisition system for meteorological station monitoring  

International Nuclear Information System (INIS)

This paper presents a study of feasibility of different existing methodologies linked to field's data acquisition from remote meteorological stations. The data transmission serves to collect field's meteorological information, such as temperature, humidity and radiation. In our study the experimental data is registered in a weather station located about 100 km from University of Almeria. Various existing techniques are studied, especially Radio, GSM (global system of mobile communication) and GPRS (general packet radio service). In the result of these studies has been designed a system of field's data acquisition (herein referred as Meteologger) which we are going to present in this paper. The system is based on an ATmega 16 microcontroller, which scans 8 sensors together at any programmable intervals. This paper presents the study of the mentioned project, application and some main characteristics of the prototype system and its program. We ...

2008-12-01

265

The luminosity function of cluster pulsars  

CERN Document Server

We study luminosities of millisecond pulsars in globular clusters by fitting the observed luminosity distribution with single and double power laws. We use simulations to model the observed distribution as the brighter part of some parent distribution for Terzan 5 and try to find a model which simultaneously agrees with the observed diffuse radio flux, total predicted number of pulsars and observed luminosity distribution. We find that wide ranges of parameters for log-normal and power-law distributions give such good models. No clear difference between the luminosity distributions of millisecond pulsars in globular clusters and normal disk pulsars was seen.

2010-01-01

266

The effect of high voltage transmission lines on agricultural land values in minnesota  

Energy Technology Data Exchange (ETDEWEB)

Overhead, high power transmission lines have secured rights of way on agricultural lands in Minnesota. The economic impact of such utility crossings, including effects on land price, was investigated. Sale records and survey data were analyzed. Buyers, sellers, and brokers were interviewed concerning inconvenience, radio interference, appearance, and loss of irrigation possibilities due to the transmission lines. In nine affected sales, there was only one case in which less money was indicated for the farm because of the presence of a transmission line.

1981-04-01

267

The effect of high voltage transmission lines on agricultural land values in Minnesota  

Energy Technology Data Exchange (ETDEWEB)

Overhead, high power transmission lines have secured rights of way on agricultural lands in Minnesota. The economic impact of such utility crossings, including effects on land price, was investigated. Sale records and survey data were analyzed. Buyers, sellers, and brokers were interviewed concerning inconvenience, radio interference, appearance, and loss of irrigation possibilities due to the transmission lines. In nine affected sales, there was only one case in which less money was indicated for the farm because of the presence of a transmission line.

1981-04-01

268

SKA in VLBI Impact on Studies of Small Scale Structures in Active Galactic Nuclei  

CERN Document Server

We discuss the advantages which the next generation interferometer SKA (the Square Kilometer Array) will bring for Very Long Baseline Interferometry (VLBI) at centimeter wavelengths. With a sensitivity to micro-Jy level flux density, a brightness temperature limit of about 10.000 K, and an expected dynamic range in future VLBI maps of better than 1.000.000, the impact of SKA on the research of compact extragalactic radio sources and their energetic jets will be very strong. We discuss some consequences, including a possible combination of SKA with future space VLBI missions.

1999-01-01

269

Recent observations of Cassiopeia A  

International Nuclear Information System (INIS)

During the last few years radio and X-ray astronomers have produced high-resolution imagery of the remnant of Cas A. Since the most recent published optical photographs of Cas A date back to 1975 it seemed worthwhile to present new optical results based on plates obtained with the 5-m Hale telescope in 1976, 1977, and 1980. The major changes that have taken place in Cas A during the last decade are: (1) A broken shell of fast-moving knots has formed along the southern and SW rim of the remnant and (2) A number of blue (oxygen-rich) filaments have developed to the north of the centre of Cas A. (Auth.).

270

Radio-frequency and microwave load comprising a carbon-bonded carbon fiber composite  

Energy Technology Data Exchange (ETDEWEB)

A billet of low-density carbon-bonded carbon fiber (CBCF) composite is machined into a desired attenuator or load element shape (usually tapering). The CBCF composite is used as a free-standing load element or, preferably, brazed to the copper, brass or aluminum components of coaxial transmission lines or microwave waveguides. A novel braze method was developed for the brazing step. The resulting attenuator and/or load devices are robust, relatively inexpensive, more easily fabricated, and have improved performance over conventional graded-coating loads.

1998-01-01

271

Radio-Frequency Beam Conditioner for Fast-Wave Free-Electron Generators of Coherent Radiation  

Energy Technology Data Exchange (ETDEWEB)

A method for conditioning electron beams is proposed, making use of the TM{sub 210} mode of microwave cavities, to reduce the axial velocity spread within the beam, in order to enhance gain in resonant electron beam devices, such as the free-electron laser (FEL). Effectively, a conditioner removes the restriction on beam emittance. The conditioner is analyzed using a simple model for beam transport and ideal RF cavities. Analysis of an FEL is employed to evaluate performance with reduced axial velocity spread. Examples of FELs are presented showing the distinct advantage of conditioning.

1991-07-01

272

Radio frequency He/sup -/ source and a source of negative ions by cesium sputtering  

Energy Technology Data Exchange (ETDEWEB)

Two sources of negative ions are described. An rf source produces up to 14 ..mu..A beams of He/sup -/ by charge exchange in Rb vapor. The other Source of Negative Ions by Cesium Sputtering (SNICS) produces a wide variety of negative ion beams in the ..mu..A range. Two important features of SNICS are its simple, compact construction and its very good beam emittance (2 to 4..pi..mm mrad MeV/sup 1/2/). Both sources have lifetimes >200 hours and they are used extensively on the Wisconsin EN tandem.

1981-04-01

273

RBS Characterization of Yttrium Iron Garnet Thin Films  

International Nuclear Information System (INIS)

Magnetic materials such as yttrium iron garnet (YIG) are of great importance for its magneto-optic properties and for their potential applications in the domain of optical telecommunications. The deposition of thin films of YIG, on quartz or GGG (gadolinium gallium garnet) substrate, was performed using radio frequency non reactive magnetron sputtering, followed by high temperature annealing which is needed to enhance the crystallinity of the layers. Rutherford backscattering spectrometry RBS was used to determine the thickness and stoichiometry of the performed layers in order to investigate correlations between growth conditions and the quality of the final material. RBS measurements showed the influence of the deposition time and the temperature substrate on the film growth and its stoichiometry. (author)

2008-12-13

274

Pure NQR quantum computing  

Energy Technology Data Exchange (ETDEWEB)

It is shown that pure NQR can be utilized as a platform for quantum computing without applying a high external magnetic field. By exciting each resonance transition between quadrupole energy levels with two radio-frequency fields differing in phase and direction, the double degeneracy of the spin energy spectrum in an electric field gradient is removed. As an example, in the case of I=7/2 (nuclei {sup 133}Cs or {sup 123}Sb) the energy spectrum has eight levels which can be used as three qubits. (orig.)

2002-07-01

275

Phase formation in gas-phase combustion and pyrolysis reactions under spark and radio-frequency discharge conditions  

British Library Electronic Table of Contents (United Kingdom)

Doped ultrafine silicon dioxide powder with a narrow particle size distribution was obtained by RF discharge-stimulated dichlorosilane (SiH2C) oxidation at a low pressure using isobutylene as the combustion inhibitor and chromium hexacarbonyl (Cr(CO)6) as the dopant. The formation and morphology of the ultrafine particles are governed by the parameters of the RF discharge and by the chemical mechanism of the combustion reaction yielding the aerosol. Submicron-sized filamentous carbon structures can be obtained by isobutylene decomposition under spark discharge conditions in the presence of a molybdenum metal catalyst.

2009-01-01

276

Operational status of the Brookhaven National Laboratory Accelerator Test Facility  

International Nuclear Information System (INIS)

Initial design parameters and early operational results of a 50 MeV high brightness electron linear accelerator are described. The system utilizes a radio frequency electron gun operating at a frequency of 2.856 GHz and a nominal output energy of 4.5 MeV followed by two, 2#pi#/3 mode, disc loaded, traveling wave accelerating sections. The gun cathode is photo excited with short (6 psec) laser pulses giving design peak currents of a few hundred amperes. The system will be utilized to carry out infra-red FEL studies and investigation of new high gradient accelerating structures.

1990-06-11

277

On the Bottom Magnetic Fields of the Millisecond Pulsars  

CERN Document Server

The magnetic field strengths of most millisecond pulsars(MSP) are about $10^{8-9}$ Gauss. The accretion induced magnetic field evolution scenario here concludes that the field decay is invesely related to the accreted mass and the minimum field or bottom field stops at about $10^{8}$ Gauss if accreted with the Eddington accretion rate, which is proportionally related with the accretion rate as $\\dot{M}^{1/2}$. The possibility of the low field $\\sim 10^{7}$ Gauss MSPs has been proposed for the future radio observation.

2003-01-01

278

NMR at earth's magnetic field using para-hydrogen induced polarization  

British Library Electronic Table of Contents (United Kingdom)

A method to achieve NMR of dilute samples in the earth's magnetic field by applying para-hydrogen induced polarization is presented. Maximum achievable polarization enhancements were calculated by numerically simulating the experiment and compared to the experimental results and to the thermal equilibrium in the earth's magnetic field. Simultaneous 19F and 1H NMR detection on a sub-milliliter sample of a fluorinated alkyne at millimolar concentration (1018 nuclear spins) was realized with just one single scan. A highly resolved spectrum with a signal/noise ratio higher than 50:1 was obtained without using an auxiliary magnet or any form of radio frequency shielding.

2011-01-01

279

Josephson effect mm-wave receivers  

International Nuclear Information System (INIS)

Josephson effect heterodyne mixers with external local oscillators are very promising low noise mm-wave receivers for applications such as radio astronomy. Experiments at 36 GHz have shown that both the noise and the conversion efficiency of mixers made using Nb point contacts are in quantitative agreement with values calculated from the resistively shunted junction (RSJ) model. Preliminary measurements at 140 GHz suggest that this agreement extends to higher frequencies. In this paper the theoretical limits to the sensitivity of such receivers are explored as a function of the signal frequency. (Auth.).

280

Initial RF measurements of the CW normal-conducting RF injector  

Energy Technology Data Exchange (ETDEWEB)

The LANL 2.5-cell, normal-conducting radio-frequency (NCRF) injector has been fabricated. We present initial results of low-power RF measurements (cavity Q, cavity field map, coupling beta, etc.) of the NCRF injector. The measured cavity Q and relative fields are found to be in good agreement with the design calculations and earlier measurements of Glidcop properties. However, the coupling beta of the ridge-loaded waveguides is found to be significantly higher than the design point. The impact of these low-power measurement results on the planned high-power RF and electron beam tests will be discussed.

2008-01-01

281

High-current negative-ion beam transport  

Energy Technology Data Exchange (ETDEWEB)

The requirements for transporting high-current, negative-ion beams are presented with particular emphasis on applications involving negative-hydrogen-ion beams. In addition to the usual matching and steering problems, particular attention must be paid to beam emittance growth in the transport system. Depending on the application, a number of approaches have been developed using both magnetic and electric lenses. I discuss the design considerations for transporting and matching these beams to radio-frequency quadrupole accelerators, and present a survey of the various types of beamlines now used for negative-ion beams.

1992-10-05

282

Guidelines on the medical therapy of persons accidentally overexposed to ionizing radiations. External contamination  

International Nuclear Information System (INIS)

The document represents a guide for the external decontamination of persons accidentally radio contaminated due to the use, production or transport of radioactive materials. The general conditions, from the medical point of view, to be kept in mind, in the event of accidental overexposures as decontamination treatment and the handling of samples are detailed throughout report. The external contamination without injury in skin or with wound its considered. The distribution of measures and responsibilities for the therapy of the irradiated patients with radioactive materials are enumerated. The preparations of decontaminate solutions are detailed in this work. Moreover, forms for the reception, physical evaluation of the patient and external contamination are presented. (author)

283

Determination of the content of elements in some wild medicinal plants of Uzbekistan by radioactivation analysis  

Energy Technology Data Exchange (ETDEWEB)

The authors have developed a complex of activation methods of analysis using a nuclear reactor (nuclear activation analysis) and a cyclotron (charged-particle activation analysis). The methods have been used to determine the concentrations of more than 20 elements in five medicinal plants native to Uzbekistan: Syrian rue (Peganum harmala L.), plantain (Plantago lanceolata), peppermint (Mentha piperata L.), sage (Salvia officinalis L.), and ziziphora (Ziziphora bungeana Yur.). The results of radio-activation analysis were compared with the results of standard spectral analysis performed in another laboratory and the accuracy of the procedures developed was evaluated on the basis of the results.

1987-06-01

284

Cosmological surveys with the Australian Square Kilometre Array Pathfinder  

CERN Document Server

This is a design study into the capabilities of the Australian Square Kilometre Array Pathfinder (ASKAP) in performing a full-sky low redshift neutral hydrogen survey, termed WALLABY, and the potential cosmological constraints one can attain from measurement of the matter power spectrum. We find that the full sky survey will likely attain 600,000 redshifts which, when combined with expected Planck CMB data, will constrain the Dark Energy equation of state to 20%, for the first time making cosmological constraints from radio observations competitive with the best existing optical surveys.

2011-01-01

285

Conceptual design of a nuclear reactor facility for medical and biological purposes  

Energy Technology Data Exchange (ETDEWEB)

Optimal neutron energy for boron neutron capture therapy (BNCT) has been studied. Epithermal neutron is superior to thermal neutrons in treating deep-seated tumors. Design of the epithermal neutron column for BNCT has been performed by using a two-dimensional transport calculation code. Aluminum and heavy water are used as moderation materials. A thermal neutron column is also designed using heavy water as thermalization material. The configuration of the facility for treatment and research of BNCT and also for basic radio-biological studies of neutrons has been presented.

1981-09-01

286

Conceptual design of a nuclear reactor facility for medical and biological purposes  

International Nuclear Information System (INIS)

Optimal neutron energy for boron neutron capture therapy (BNCT) has been studied. Epithermal neutron is superior to thermal neutrons in treating deep-seated tumors. Design of the epithermal neutron column for BNCT has been performed by using a two-dimensional transport calculation code. Aluminum and heavy water are used as moderation materials. A thermal neutron column is also designed using heavy water as thermalization material. The configuration of the facility for treatment and research of BNCT and also for basic radio-biological studies of neutrons has been presented. (author).

287

CT findings of foreign bodies in the chest: a pictorial essay  

Energy Technology Data Exchange (ETDEWEB)

The most common causes of tracheobronchial foreign bodies are peanuts in children, and meat and dentures in adults. The most common causes of esophageal foreign bodies are coins in children and meat in adults. It is passable to diagnose a foreign body by visualization on a chest radiograph, if the foreign bodies are radio opaque. However, if the foreign bodies are radiolucent and the patients do not remember the history of aspiration, it is important to evaluate CT findings for foreign bodies and their complications. We describe the CT findings of various thoracic foreign bodies in children and adults.

2008-05-15

288

Bone geometry, biomechanics, and mineral content of the distal radius in uremic patients with severe hyperparathyroidism; Valutazione delle proprieta' geometriche, biomeccaniche e osteodensitometriche del radio ultradistale mediante tomografia computerizzata quantitativa periferica nei pazienti uremici affetti da iperparatiroidismo grave  

Energy Technology Data Exchange (ETDEWEB)

Bone integrity and mineral status were studied with a noninvasive method in uremic patients with severe secondary hyperparathyroidism undergoing maintenance hemodialysis. [Italian] Gli autori propongono un metodo non invasivo per studiare la densita' minerale e le caratteristiche geometriche e biomeccaniche dell'osso nei pazienti uremici affetti da iperparatiroidismo secondario grave.

1999-04-01

289

An investigation of the retention of some radioelements on natural fibers  

International Nuclear Information System (INIS)

The retention of radio-Eu, Go, Cs and Sr, at the tracer level, on raw fibers produced from hemp, linen and Jute plants was investigated. The study was conducted from different media including: sea and tap waters, sodium chloride and nitric acid solutions of different Ph. The percentage retention and elution, on prolonged contact, varied from one element to another depending on conditions. Extraction chromatography columns, using these fibers as supporting material were also experimented. Results were discussed together with possible applications. 7 tabs.

290

Statistical mapping analysis of serotonin synthesis images generated in healthy volunteers using positron-emission tomography and alpha-[11C]methyl-L-tryptophan.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To assess the suitability of analyzing functional images of brain serotonin (5-HT) synthesis with statistical parametric mapping (SPM), and to investigate further possible sex-related regional...Full Text Available

2000-09-01

291

Single photon emission computed tomography and its neurological application  

Energy Technology Data Exchange (ETDEWEB)

A review is made of the various brain imaging agents utilised in the post few years with their own characters and respective advantages: cerebral blood volume tracers, non diffusible tracers, diffusible tracers among which gases and lipophilic agents. Our results with IAMP and SPECT are presented in two different clinical application fields: normal pressure hydrocephalus and cerebral ischemia.

1984-12-01

292

Single photon emission computed tomography and its neurological application  

International Nuclear Information System (INIS)

A review is made of the various brain imaging agents utilised in the post few years with their own characters and respective advantages: cerebral blood volume tracers, non diffusible tracers, diffusible tracers among which gases and lipophilic agents. Our results with IAMP and SPECT are presented in two different clinical application fields: normal pressure hydrocephalus and cerebral ischemia.

293

Role of CT in TNM staging of laryngeal and hypopharyngeal tumors  

International Nuclear Information System (INIS)

70 patients with squamouscell carcinoma of larynx and hypopharynx were examined by computed tomography; the TNM staging of tumors by CT, by endoscopy and by surgical operation was reviewed. CT proved to be reliable both to recognize the presence of neoplasms, with the exception of those very superficial, and their deep spreading to preepiglottic and paralaryngeal spaces, to the soft tissues of the neck and to the cartilages. Therefore CT is the examination of choice in laryngeal neoplasms staging, because it precisely completes the clinical and endoscopical informations.

1986-01-01

294

Right-sided invasive metastatic thymoma of the heart  

British Library Electronic Table of Contents (United Kingdom)

Cardiac tumours may display diverse symptoms through potential involvement of any structure of the heart. We describe a case of a highly malignant thymoma with involvement of different cardiac structures with important haemodynamic compromise. With the high sensitivity of transthoracic echocardiography for detection of intracardiac masses, computed tomography and magnetic resonance add essential structural preoperative information on the tumour and surrounding tissue as vessels, pleura, lung and mediastinum.

2011-01-01

295

Preparation and radiolabeling of IBZM: a potential D-2 specific brain imaging agents for SPECT  

International Nuclear Information System (INIS)

In developing new receptor-site specific brain imaging agents labeled with I-123 for single photon emission computed tomography (SPECT), an analog of raclopride, 3-["1"2"5I]-iodo-N-[(1-ethyl-2-pyrrolidinyl)-methyl]-2-hydroxy-6-me-thoxy benzamide (IBZM), was prepared using a method similar to that reported for raclopride and its derivatives. (author).

296

PET and MR imaging in a neuro-Behcet syndrome  

Energy Technology Data Exchange (ETDEWEB)

Positron emission tomography (PET) and magnetic resonance imaging (MRI) studies were performed on a case of neuro-Behcet's syndrome. In accordance with the clinical signs, FDG PET (using /sup 18/F-labeled 2-F-2'-desoxyglucose) revealed disseminated storage defects in the cerebrum and cerebellum. Focal regions of enhanced signal intensity were demonstrated in the parietal white matter of the cerebrum in T2-weighted images and in the brain stem by MRI. (orig.).

1989-11-01

297

New concept to optimize emergency diagnoses in patients with multiple injuries  

International Nuclear Information System (INIS)

To optimize the emergency care of patients with multiple injuries, a special emergency room with integrated radiological equipment has been developed. It consists of a linear array of a computed tomography system, a mobile C-arm with an integrated scattered radiation grid for conventional films and a C-arm fluorographic system. The intent is to avoid delay caused by transport and repositioning of the patient. It enables all necessary diagnostic procedures to be performed within a minimal amount of time. (orig./MG).

298

Monte Carlo design calculations for a neutron imaging facility collimator  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for computed tomography and real-time neutron radiography is being developed at the University of Texas at Austin. The TRIGA reactor is a graphite-reflected Mark It pool-type research reactor. The neutron imaging facility will use beam port, which is at one end of a through part. Monte Carlo calculations were used to design the neutron collimator for this facility.

1996-12-31

299

Kinetic estimation of infused Lipiodol within hepatoma using CT dynamic study  

Energy Technology Data Exchange (ETDEWEB)

Distribution of Lipiodol within hepatic tumor was evaluated using serial computed tomography. Imagistic Lipiodol transition into the tumor via hepatic artery was slower than that of water soluble contrast medium, spreading to central part first and turn to peripheral part of the tumor. This method was thought to be useful to clarify Lipiodol distribution in hepatic tumor and to decide the method or necessity of additional trans-arterial therapy. (author).

1991-02-01

300

Development of an experimental installation for short-lived isotopes production in INR linac  

International Nuclear Information System (INIS)

A possibility of short-lived isotopes production in inter-tank section between the first and the second drift tube tanks (20.45 MeV) in INR linac is considered. At the initial stage the main efforts are concentrated on production of fluorine-18 used for positron emission tomography. The results of beam forming calculations, target heating calculations, equipment activation calculations as well as installation configuration and design are presented.

2010-01-01

301

Computed tomography of the urinary bladder. Clinical application of the olive oil-filled method  

Energy Technology Data Exchange (ETDEWEB)

Out of one hundred cases of the urinary bladder abnormalities examined by this method, CT staging and pathological correlations were investigated in 61 cases of the urinary bladder neoplasms. Accuracy of CT staging was 87% in this series with possible exception of 6 cases involving the bladder base and dome. CT scan using this method is the most reliable procedure to determine the treatment modalities of the urinary bladder tumors.

1982-01-01

302

Computed tomography of the chest: A teaching file  

Energy Technology Data Exchange (ETDEWEB)

As a self-teaching tool, this illustrated guide facilitates home study of the complexities of thoracic CT's. Over 400 illustrations and accompanying copy are used to provide a basis for understanding the CT appearances of disease processes and a comparison of CT lookalikes. It updates new and interesting developments in the format of case presentations.

1987-01-01

303

Computed tomography of intrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Intrahepatic cholangiocarcinoma is an uncommon tumor as primary hepatic neoplasm. Five cases of cholangiocarcinoma, mass forming peripheral type, are reported about its CT findings. They were manifested as a poorly marginated low density mass with a irregular stellate area. In one case, a cut section of the gross specimen following surgery showed a central callagenous scar and vessels within the necrotic tumor. (author).

304

Complete Dissection of a Hepatic Segment after Blunt Abdominal Injury Successfully Treated by Anatomical Hepatic Lobectomy: Report of a Case  

UK PubMed Central (United Kingdom)

A 21-year-old male patient was transferred to the emergency room of our hospital after suffering seat belt abdominal injury in a traffic accident. Abdominal computed tomography revealed a massive hematoma...Full Text Available

305

Clinical helical tomotherapy commissioning dosimetry  

International Nuclear Information System (INIS)

Helical tomotherapy presented many unique dosimetric challenges and solutions during the initial commissioning process, and some of them are presented. The dose calculation algorithm is convolution/superposition based. This requires that the energy fluence spectrum and magnitude be quantified. The methodology for doing so is described. Aspects of the energy fluence characterization that are unique to tomotherapy are highlighted. Many beam characteristics can be measured automatically by an included megavoltage computed tomography imaging system. This greatly improves data collection efficiency.

2003-12-01

306

CT scan findings in cerebral paragonimiasis  

International Nuclear Information System (INIS)

Computed tomography was performed on 5 patients with chronic cerebral paragonimiasis. CT showed solitary or multiple, amorphous, round, or oval calcifications, and ventricular enlargement in all 5 cases. A large low-density area is also found in 4 of the 5 cases. These CT findings are compatible with previously reported findings of simple X-ray films of the skull, pneumoencephalography, and pathological studies. (author).

1982-01-01

307

CT imaging of a primary malignant mixed mullerian tumor arising from the peritoneum  

British Library Electronic Table of Contents (United Kingdom)

Primary peritoneal malignant mixed mullerian tumors are very rare. We report the case of a patient presenting with pain in the right upper quadrant of the abdomen and in whom the physical examination demonstrated a peritoneal mass. Computed tomography (CT) confirmed the presence of a mass, with invasion of adjacent organs.

2008-01-01

308

Bilateral enlargement of the orbital muscles: first manifestation of renal adenocarcinoma; Espessamento da musculatura extrinseca orbitaria bilateralmente: manifestacao primaria de adenocarcinoma renal  

Energy Technology Data Exchange (ETDEWEB)

The authors present an unusual case of a patient with orbital metastases from renal carcinoma involving the extra ocular muscles bilaterally. The importance of computed tomography for the differential diagnosis with other orbital lesions is emphasized. (author)

2000-06-01

309

Atlas of nuclear medicine imaging  

Energy Technology Data Exchange (ETDEWEB)

An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)

1981-01-01

310

The operation status and prospect of radioisotope production facility in HANARO  

Energy Technology Data Exchange (ETDEWEB)

Researches and production of radio-isotopes, radio-pharmaceuticals and cold kits are carried out in the Radio-isotope Production Facility (RIPF). Four concrete hot cells in Bank-1 are to produce the Ir-192 source for NDT. Eleven lead hot cells in Bank-2 are to produce Ho-166, Cr-51, P-32/33, Tc-99m, Lu-177, Sr-90/Y-90 and W-188/Re-188 for research purpose. Six lead hot cells in Bank-3 are used for the production of I-131 for diagnosis and therapy of cancer in the hospital. A hot cell in Bank-3 is also utilized for the research of I-125 and Br-82. Four lead hot cells in Bank-4 are utilized for the production of Mo-99/Tc-99m generators since 2005. The major systems including the Heat and Ventilated Air Conditioning (HVAC) system and the air cleaning system such as charcoal and HEPA filter trains to filter the radioactive contaminants are in operation. So are the systems such as power supply and distribution system, UPS, fire ...

2008-11-15

311

Study of radionuclide contributing to dose rates in 540 MWe plant environment  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station Unit-4 is first 540 MWe pressurized heavy water reactor in India. It achieved criticality on 06th March 2005 and then operated at full power i.e 500 MWe. Radiation workers during the normal operation and reactor shutdown are exposed to radiation field. The control of dose rates and the collective dose of the radiation workers is most important for the best performance of the reactor. Experience gained during the operation of the 220 MWe reactors has shown that the Moderator system, primary heat transport system, annulus gas system and moderator cover gas system are the main systems contributing to the dose rate and collective dose. In order to identify the radio nuclides contributing to the radiation field, study was undertaken at TAPS Unit-4. Various samples from the Moderator, primary heat transport system, annulus gas system and moderator cover gas system were collected and analysed for the spectrometric analysis. This paper ...

2005-11-23

312

Global positioning automatic vehicle location system  

Energy Technology Data Exchange (ETDEWEB)

Los Alamos National Laboratory (LANL) is a unique facility covering over 43 square miles. The Emergency Management and Response Office (EM&R) is required to respond, provide Incident Command (IC), and coordination for all Laboratory emergencies. This requires IC`s and support staff to respond to the actual scene of the incident. Since the IC is under numerous constraints and stress, the office wanted the capability of locating the EM&R vehicles on an electronic map. An automated vehicle location (AVL) system was required for the additional safety of the emergency response personal. The requirements for the AVL system include total automatic tracking and low cost. After careful consideration, it was determined that the most efficient and cost effective system would be based on packet radio technology as the transmission media. The location is determined by the Department of Defense Global Positioning System (GPS). The system that was designed and constructed ...

1997-03-01

313

Ultrasonography and Computerized Tomography in the diagnosis of complex abdominal lesions  

International Nuclear Information System (INIS)

Complex abdominal lesions include a variety of pathologies, such as septated, infected, and hemorrhagic cysts, abscesses, tumors, and fluid collections of different ethiology. These lesions present diagnostic difficulties with both Ultrasonography (US) and Computed Tomography (CT), since findings may not be present or, when present, are not specific. Keeping these limitations in mind, we evaluated 105 patients (111 abdominal lesions) with both US and CT in order to compare their adequacy in predicting the nature of the lesion. On the basis of US and CT results, complex abdominal lesions were divided in four classes: class I includes 43 cases in which both examinations gave the same contribution to the definition of the nature of the lesion, class II (14 lesions, mainly sperimentated cysts), in which US was superior to CT, class III includes 45 cases of hemorrhagic cysts, abscesses, fluid collections and, less frequently, cystic tumors; class IV includes 9 cases in ...

1988-01-01

314

The role of computed tomography in complex facial trauma  

Energy Technology Data Exchange (ETDEWEB)

Tridimensional localization of bone and soft tissue injuries in complex facial trauma is fundamental for treatment. The face can be conceptualized as 3 groups of interconnected osseous struts that are oriented in the horizontal, sagittal and coronal planes. Each group of struts is closely related to specific soft tissue structures that are susceptible to injury. Any single CT section in the coronal plane or in the axial plane contains parts of one or more these struts. Facial CT in biplane were performed in 32 patients of facial trauma. The most common site of facial fractures is found in middle part of horizontal struts, geometrically in anteromedial portion of the inferior orbital fissure of the face. The most common soft tissue injury combined with facial fracture is hematoma and/or herniated orbital contents into the maxillary sinus. The serious combined soft tissue injuries were ocular rupture, retroorbital hematoma and optic nerve injury resulting blindness. CT was superior to ...

1988-02-15

315

Sinonasal malignant tumors involvement of the orbit and skull: a computed tomography study  

International Nuclear Information System (INIS)

Malignant tumors of the sinonasal cavities are rare and often diagnosed late in the course of the disease. These tumors can extend into regions such as the orbit and brain, where treatment is difficult. Ten patients with non treated sinonasal malignant neoplasms and radiological evidence of tumor extension into the orbit and brain were studied with computed tomography. Five (50%) tumors were epithelial neoplasms whereas squamous cell carcinoma was the most common type (3 cases). The ethmoidal sinus was the most common site of origin of the tumors (40%), followed by the maxillary sinus (30%) and nasal cavity (30%). A total of 16 orbits were involved since 6 patients (60%) had bilateral orbital involvement. The tumors extended more often into the orbits through erosion of the medial and inferior orbital bones. All orbital compartments were involved in the majority of the orbits. Tumoral extension into the cranial cavity was more common through the ethmoidal (70%) and ...

2002-01-01

316

Risks and safety aspects related to PET/MR examinations  

International Nuclear Information System (INIS)

The introduction of positron emission tomography (PET)/magnetic resonance (MR) systems into medical practice in the foreseeable future may not only lead to a gain in clinical diagnosis compared to PET/computed tomography (CT) imaging due to the superior soft-tissue contrast of the MR technology but can also substantially reduce exposure of patients to ionizing radiation. On the other hand, there are also risks and health effects associated with the use of diagnostic MR devices that have to be considered carefully. This review article summarizes biophysical and biological aspects, which are of relevance for the assessment of health effects related to the exposure of patients to both ionizing radiation in PET and magnetic and electromagnetic fields in MR. On this basis, some considerations concerning the justification and optimization of PET/MR examinations are presented - as far as this is possible at this very early stage. Current safety ...

2009-03-01

317

Reflection tomography using finite element method ray tracing  

Energy Technology Data Exchange (ETDEWEB)

The seismic reflection exploration technique which is one of the geophysical methods for oil exploration became effectively to image the subsurface structure with rapid development of computer. As a tool to perform seismic inversion, seismic forward modeling program using ray tracing should be developed. In this study, we have developed the algorithm that is to calculate the travel time of the complex geological structure using ray tracing by subdividing the geologic model into triangular element (finite element) having the constant velocity. We can analytically calculate Jacobian with some information by this current ray tracing. With this Jacobian, we will develop new algorithm which is to obtain geological properties and to image the subsurface. Since the FEM (Finite Element Method) ray tracing we have developed goes well the inverse velocities structure, we can apply the inversion problem to complex geological model. This report consists of 3 articles. 1) Development of 2-D ...

1996-12-01

318

Real-time cross-sectional averaged void fraction measurements in vertical annulus gas-liquid two-phase flow by neutron radiography and X-ray tomography techniques  

Energy Technology Data Exchange (ETDEWEB)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray CT technique. (orig.).

1995-03-11

319

Real-time cross-sectional averaged void fraction measurements in vertical annulus gas-liquid two-phase flow by neutron radiography and X-ray tomography techniques  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed Tomography (X-CT) system are used to determine the flow regime, the instantaneous cross-sectional averaged void fraction, and the time averaged void fraction in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements are obtained for gas flow rates form 0.0 to 30.0 l/min. The flow regimes observed by all three measurement systems via image analysis shows that the results agree well with each other. Both the RTNR and the X-CT systems show that the time averaged and cross-sectional averaged void fraction increases with increasing superficial gas velocity. Time and cross-sectional averaged void fractions determined by the RTNR system agree within 4% with those determined by the high speed X-ray CT technique. (orig.).

1995-03-01

320

Production of radiopharmaceuticals for positron emission tomography via laboratory robotics  

International Nuclear Information System (INIS)

The production of radiopharmaceuticals used in positron emission tomography (PET) can require large amounts of activity at the start of synthesis in order to yield sufficient labeled material for clinical studies. Several investigators have developed remote and automated systems for the routine production of PET radiopharmaceuticals in order to reduce radiation exposure to personnel. Such devices, however, suffer from limited flexibility and can be relatively complicated in design. These systems are also limited to the production of a single or a few closely related compounds. Furthermore, changes in chemistry would require considerable modifications in hardware and/or software in order to bring the device back into operation. To circumvent the above limitations associated with the remote production of PET radiopharmaceuticals, the authors have investigated the use of laboratory robotics as a flexible alternative to the synthesis of several short-lived ...

1987-11-15

321

Improvement of FCR-linear tomography using digital image processing  

Energy Technology Data Exchange (ETDEWEB)

In order to improve the image quality of linear tomography performed with the Fuji Computed Radiography (FCR) system, we have examined one-dimensional unsharp mask filtering to reduce blur formed in the direction of tomographic swing. We determined a mask size and a weighting factor of the image processing suitable to obtain a quality tomogram. The mask size of 41 x 1 pixels for a 14 x 14'' imaging plate, which modifies the original image date and results in demonstrating a peak frequency at 0.2 cycles/mm for spatial frequency spectrum, is superior in showing fine vessel structures and morphological features of pathology in the lung fields. An additional spatial frequency filtration in the direction perpendicular to the tomographic movement reduces the blur and clearly demonstrates object contours running parallel to the tube movement. However, the additional filtration increases the appearance of noise on the processed image and offsets the ...

1994-02-01

322

High resolution computed tomography in the study of cervical spine trauma  

International Nuclear Information System (INIS)

Correct ortopedic therapy for traumas of the cervical rachis requires perfect knowledge of the spatial balance of the fracture focus. The authors belive Computed Tomography (CT) to be the most suitable, and often indispensable, method for this purpose. Twenty-four patients were examined for traumatic pathology of the cervical rachis. In 7 cases with clinically minor traumas, the negative outcome of the traditional traumas, the negative outcome of the traditional exam was considered reliable and sufficient for therapeutic purposes. The extant 17 patients were examined also by means of CT, either to better dermine the characteristics of skeletal lesions already ascertained with traditional techniques or to asses the presence of clinically-suspected osteo-articular lesions, even with negative conventional X-rays. For 9 of these patients orthopedic treatment was considered sufficient, whereas 8 patients underwent surgery and were subsequently examined with CT, which ...

1989-01-01

323

Ganglioneuromas in childhood: MRI and CT characteristics  

International Nuclear Information System (INIS)

Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T_1-weighted scans the tumors ...

2000-05-01

324

Focal lesions in external auditory canal: computed tomography images  

International Nuclear Information System (INIS)

To analyze and review the most common focal lesions of the external auditory canal (EAC), describing the computed tomography (CT) findings. The CT images of EAC were reviewed in a series of 167 patients. Abnormal findings were recorded in 13 cases. The CT images were correlated with otoscopic and/or intraoperative findings. There were four cases of osteoma (one located outside the EAC); all of which were treated surgically, as was the one case of exostosis. Six patients presented debris in EAC, coinciding with clinical evidence of external otitis. There were two cholesteatomas derived from EAC, one of them secondary to survery to treat osteoma. On patient was diagnosed as having a basal cell carcinoma of the ear, extending to EAC, but refused to undergo surgery. Five patients presented small triangular laminae of dense bone arising from the upper wall of the EAC which were defined as abnormal variants of the fusion of the temporal squamous epithelium to the ...

325

Exploring the mechanism of radiation-enhanced hepatocellular carcinoma cell invasion by swept source optical coherence tomography  

Science.gov (United States)

Ionizing radiation is a standard treatment for various human solid tumors. However, several clinical studies showed that a significant proportion of patients undergoing radiotherapy for hepatocellular carcinoma (HCC) develop intrahepatic and extrahepatic metastasis. Understanding of radiation-induced cancer cell invasiveness and behavior is essential and of great important for developing suitable treatment strategies to contain cancer spread. Therefore, in this study we evaluated the effectiveness of using swept source optical coherence tomography (SS-OCT) to monitor the enhancement of HCC cell invasiveness by radiation. SS-OCT images were acquired and recorded to obtain three-dimensional data sets per four hours in 48 hours after irradiating HepG2 cells with 7.5 Gy. The cell migration behavior in three-dimensional tissue models was quantified from images of radiation-induced and sham-irradiated cells.

2011-02-01

326

Digital image precessing for neutron television fluoroscopic system and its application to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the reconstructed image. The image quality could be satisfactory to distinguish acrylic ...

1984-09-01

327

Digital image precessing for neutron television fluoroscopic system and its application to neutron computed tomography  

International Nuclear Information System (INIS)

The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the reconstructed image. The image quality could be satisfactory to distinguish acrylic ...

1984-01-01

328

Diagnostic possibilities following implantation of carbon-fibre-reinforced plastic (CFRP) total hip arthroplasty  

International Nuclear Information System (INIS)

Introduction: There are many problems in the radiological diagnosis of aseptic loosening in total hip arthroplasty. Computed tomography (CT) and magnetic resonance tomography (MRT) are not usable for metallic implants (stainless steel, cobalt alloy, titanium alloy). Material and Methods: From April 1993 to December 1993 15 CFRP non-cemented hip prostheses have been implanted. In a prospective clinical study plane radiographs, CT and MRT have been analysed. Results: Three stems were revised (1 femoral fracture, 1 severe thigh pain, 1 aseptic loosening). CFRP are not visible in plane radiographs. There was a complete (two-third of the cases) or nearly complete (one-third of the cases) small sclerotic interface between the prosthesis and the bone, these were apparent in CT and MRT in stable implant cases and did not have any clinical correlations. Discussion: The small sclerotic interface is quite different in comparison to so called 'Reactive ...

329

Diagnostic Performance of Computed Tomography Colonography in Symptomatic Patients and in Patients with Increased Risk for Colorectal Disease  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate the diagnostic performance (colorectal lesions) of computed tomography (CT) colonography in 111 patients, a majority of whom were at high risk for colorectal neoplasia. Material and Methods: After bowel preparation, CT colonography was performed, immediately followed by conventional colonoscopy. The diagnostic performance of CT colonography was analyzed relative to lesion size, histological diagnosis, and diagnostic certainty. Results: The sensitivity of CT colonography increased with lesion size (P<0.001), and was 91% (21/23) for lesions > or = 10 mm. All 10 carcinomas and 86% (19/22) of adenomas > or = 5 mm were detected. Unconfirmed or false-positive CT findings were generally small and/or reported with low diagnostic certainty. The specificity of CT colonography would be 45% (30/66; 95% CI 34% to 57%) if patients with findings of any size and any diagnostic certainty were selected for follow-up, and 92% (85/92; 95% CI ...

2006-11-15

330

Cross-sectional void fraction distribution measurements in a vertical annulus two-phase flow by high speed X-ray computed tomography and real-time neutron radiography techniques  

Energy Technology Data Exchange (ETDEWEB)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,{theta}) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.

1995-09-01

331

Cross-sectional void fraction distribution measurements in a vertical annulus two-phase flow by high speed X-ray computed tomography and real-time neutron radiography techniques  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system and a high speed X-ray Computed tomography (X-CT) system are compared for measurement of two-phase flow. Each system is used to determine the flow regime, and the void fraction distribution in a vertical annulus flow channel. A standard optical video system is also used to observe the flow regime. The annulus flow channel is operated as a bubble column and measurements obtained for gas flow rates from 0.0 to 30.01/min. The flow regimes observed by all three measurement systems through image analysis shows that the two-dimensional void fraction distribution can be obtained. The X-CT system is shown to have a superior temporal resolution capable of resolving the void fraction distribution in an (r,#theta#) plane in 33.0 ms. Void fraction distribution for bubbly flow and slug flow is determined.

1995-09-01

332

Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard  

Energy Technology Data Exchange (ETDEWEB)

The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Bjoerk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic valve replacements, two redo mitral replacements and one Amplatzer ductal occluder occlusion of a ...

2009-04-15

333

Computer assisted axial tomography (Emi scan) in neurologic investigation  

Science.gov (United States)

Cerebral angiography, pneumoencephalography, and radioisotope brain scan with their differing diagnostic abilities have provided the neurologist and neurosurgeon with extremely valuable diagnostic techniques. It is doubtful, however, if any of these now conventional methods had the enormous impact on the practice of neurology that computer assisted axial tomography (C.A.T.) is beginning to have. Here, for the first time, is a test which, without significant risk or discomfort, can demonstrate some normal intracranial (and intraorbital) structures, can demonstrate some normal intracranial pathology and, in many cases, can make the potentially dangerous contrast studies unnecessary. After only a few months experience with C.A.T. in a clinical setting, it has become obvious that there will have to be a reappraisal of the accepted investigative work-up of many conditions. While it is too early to have formulated strict criteria for the use of C.A.T., this paper is an ...

1974-01-01

334

Computed tomography of the mediastinal tumor  

Energy Technology Data Exchange (ETDEWEB)

Forty-one cases of mediastinal tumor examined by computed tomography were reviewed. CT findings of the mediastinal malignancy were as follows: 1) inhomogeneous density on contrast CT, 2) equivocaton of fat plane surrounding the tumor, 3) irregular margin. Benign teratoma had smooth margin and included fat or calcification density. Mediastinal seminoma was observed as a lobulated mass with no calcification on CT. These findings were similar to the patterns of malignant thymoma or lymphoma. Consequently, it was very difficult to differentiate between malignant thymoma and malignant lymphoma by CT. According to our data, malignant thymoma tended to expand to only one side of the anterior mediastinum and to invade the anterior chest wall. On the other hand, malignant lymphoma of anterior medistinal type expanded into the trachea and the superior vena cava. In patients with sarcoidosis, the enlargement of bilateral hilar lymph nodes was commonly observed, on the ...

1984-12-01

335

Computed Tomography in staging and follow-up of thoracic Hodgkin's diseases  

International Nuclear Information System (INIS)

As yet, the role of Computed Tomography (CT) as a routine imaging technique in the staging and follow-up of thoracic Hodgkin's disease has not been assessed. The authors reported the results obtained in 120 patients affected with thoracic Hodgkin's disease, staged and followed by means af chest X-rays and CT. CT better identified intrathoracic involvement of mediastinal nodes, of lung parenchyma, of pleura, and of pericarcial and chest walls in 54/120 patients (45%), with staging modifications in 18 (15%) of them only. Treatment was changed only in 12 patients (19%) where radiation therapy had been planned. The clinical value of the additional information yielded by CT was especially evident in the follow-up: CT allowed the correct evaluation of persistent/ recurrent disease in 51/117 patients (43.5%), a figure high enough to suggest the use of CT in the routive follow-up of patients affected with thoracic Hodgkin's disease.

1990-01-01

336

Combining anatomy and function: the path to true image fusion  

Energy Technology Data Exchange (ETDEWEB)

Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localization of abnormalities. The resulting correlation of the anatomical and functional images may clarify the nature of the abnormality and help diagnose or stage the underlying disease. Whereas successful image fusion software has been developed for the brain, only limited success has been achieved for image alignment in other parts of the body. The development and current status of alternative approaches are presented. Dual-modality imaging is described with devices where two modalities are combined and mounted in a single gantry. The use of existing scanner technology ensures that no compromises are made in the clinical efficacy of either the anatomical or functional imaging ...

2001-10-01

337

Body weight-tailored contrast material injection protocol for 64-detector row computed tomography coronary angiography  

International Nuclear Information System (INIS)

The aim of this study was to assess the body weight-tailored contrast material injection protocol for 64-detector computed tomography (CT) to maintain optimal coronary CT attenuation. A total of 60 patients who underwent CT coronary angiography were assigned to one of three groups: protocol A, total of 0.7 ml kg"-"1 with 300 mg I/ml iodine concentration; protocol B, total of 0.6 ml kg"-"1 with 350 mg I/ml; protocol C, total of 0.7 ml kg"-"1 with 350 mg I/ml. The injection duration was 10 s in all patients. The proportion of intracoronary attenuation values >325 Hounsfield unit (HU) was compared on a per-vessel and per-patient basis. The attenuation value was significantly more likely to exceed 325 HU with protocol C (95% for reader 1 and 90% for reader 2) than with protocol A or B on the per-vessel analysis (P325 HU) with 64-detector CT when using an injection duration of 10 s. (author)

2011-01-01

338

Body dose conversion factors for computerized tomography  

International Nuclear Information System (INIS)

While there have been many experimental and calculational investigations on absorbed dose distribution in the patient resulting from conventional X-ray procedures, such data for computerized tomography (CT) are still sparse. As this diagnostic procedure has shown a rapid increase in application during recent years, we have determined absorbed dose to body organs in a human phantom resulting from CT examinations. The exposure model consists of the heterogeneous MIRD-5 phantom and a suitable Monte-Carlo method to calculate absorbed dose to organs of interest. The exposure conditions are specified according to the exposure specifications of a CT-scanner currently in use. The calculations cover the range of body tissues of interest in terms of organ absorbed doses as well as a risk weighted absorbed dose. A detailed example showing the calculation of red bone marrow dose is given and a somatic effective dose equivalent Hsub(ES) is calculated for different conventional ...

1980-10-31

339

Application of 18F-fluorodeoxyglucose positron emission tomography to detection of proximal lesions of obstructive colorectal cancer  

International Nuclear Information System (INIS)

In cases of obstructive colorectal cancer (CRC), preoperative diagnosis of the proximal lesion is often difficult when the primary lesion impedes the passage of the endoscope. The aim of this study was to evaluate the usefulness of fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) in such cases. A total of 52 obstructive CRC patients who underwent preoperative FDG-PET and subsequent surgical resection were retrospectively reviewed. The correlation between characteristics of the proximal lesion and FDG-PET findings was analyzed statistically. There was a significant correlation between the proximal lesion size and the maximum standardized uptake value (P=0.00016). Abnormal FDG accumulation in the proximal colon indicated the existence of proximal cancer or adenoma with a sensitivity of 50% and a specificity of 100%. There was a significant difference in the distribution of tumor size between the cases with proximal abnormal accumulation and those ...

2010-10-01

340

A look ahead: PET/MR versus PET/CT  

Energy Technology Data Exchange (ETDEWEB)

Integration of positron emission tomography (PET) and magnetic resonance (MR) has become a topic of increasing interest to the imaging community over the past two years. In this text, the authors attempt to distinguish facts from fiction concerning such integrated systems. Analysis of existing information of combined imaging on existing brain PET/MR systems and imaging experience with PET-computed tomography (CT) is reviewed. Various types of system integration of PET and MR are discussed with completely independent systems on one hand and completely integrated systems with the possibility of simultaneous data acquisition on the other hand. Furthermore, it is discussed, what simultaneous data acquisition with nuclear imaging systems combined with MR or CT really means, as technical simultaneity may not be relevant in light of the pharmacokinetics of the nuclear tracers used. The authors conclude that combining PET/MR is an interesting research ...

2009-03-15

341

Value of computed Tomography in re-staging patients undergoing second-look laparotomy for ovarian cancer  

International Nuclear Information System (INIS)

Twenty-five patients with ovarian carcinoma who had been operated and treated with chemotherapy underwent clinical examination and CT before reintervention (second-look laparotomy) to detect the presence of eventual recurrences. The prediction of recurrence based on CT and clinical findings was compared with the surgical findings at reintervention. CT proved to be more accurate than clinical examination in detecting recurrences; this was especially true for masses in the abdominal cavity, with the exception of small peritoneal nodules. The authors suggest the use of CT for staging the patients candidate to reintervention. This might help to avoid reintervantion in patients with persistent disease and to plan treatment.

1991-01-01

342

Technetium complexes as potential brain imaging agents  

International Nuclear Information System (INIS)

Single photon tomography using lipophilic tracers provides tomographic representations of regional blood flow. To penetrate a healthy blood-brain barrier requires that radiotracers either are fat-soluble or have an affinity for one of the selective blood-brain barrier transport systems. In recent years there has been an increasing interest to explore the ideal physical characteristics of "9"9"mTc for diagnostic problems of brain diseases. The development of radiopharmaceuticals for brain imaging including the intensively studied "9"9"mTc-propyleneamineoxime derivatives is discussed. (author).

343

Successful coil embolization of an unusual aorto-superior mesenteric vein fistula.  

Science.gov (United States)

The aortovenous fistulas are rare, most of them are aortocaval fistula. The non-caval communication of the fistula is sparse. Herein we report a 47-year-old female diagnosed as traumatic aorto-superior mesenteric vein (Ao-SMV) fistula. The abdominal pain, fullness, and frank bruit on abdominal auscultation suggested the diagnosis of an intra-abdominal arteriovenous fistula. The diagnosis of Ao-SMV was further confirmed by the computed tomography (CT) and aortography. The fistula was successfully treated with transcatheter coil embolization. This is the first case of Ao-SMV fistula. It provides an alternative option of treatment other than conventional surgery. PMID:19327940

2009-03-26

344

Spectrum of abdominal pathologies detected with CT in long term dialysis patients  

Energy Technology Data Exchange (ETDEWEB)

As a consequence of the expanded use of long term hemodialysis and continuous ambulatory peritoneal dialysis (CAPD) treatments and extended life spans, complications of end-stage renal disease and dialysis treatments are being encountered with increasing frequency in these patients. Computed tomography can accurately depict many of the potential complications of end-stage renal disease on dialysis. This article presents the abdominal CT findings of 429 end-stage renal disease patients who are on either hemodialysis or continuous ambulatory peritoneal dialysis treatment.

2009-11-15

345

Sonography and Computed Tomography in the evaluation of giant Baker's cysts  

International Nuclear Information System (INIS)

The US study of the posterior compartment of the knee usually allows the clinical suspicion of popliteal cyst to be confirmed. Neverthless, in case of giant Baker's cysts - which are, at any rate, less frequent -US diagnosis is more difficult. CT can help determine the benign nature of the lesion, and hallow an accurate spatial evaluation. Moreover CT, when accurately performed, demonstrates the caudal or cranial cystic spread, together with its clear separation from adjacent muscular tissues. Direct coronal scans are more useful to obtain better spatial definition than reformatted images.

1991-01-01

346

Role of positron emission tomography-computed tomography in staging and early chemotherapy response evaluation in children with neuroblastoma  

International Nuclear Information System (INIS)

To evaluate the role of positron emission tomography-computed tomography (PET-CT) in staging and determining early treatment response to chemotherapy in children with neuroblastoma (NB) and its correlation with the final outcome. Patients and Methods: Seventeen patients of NB with mean age of 51.5 months (age range 2-132 months; 14 males, 3 females) underwent serial "1"8F-fluorodeoxyglucose (FDG) PET-CT imaging. All 17 patients were for staging before any treatment. Twelve of 17 patients underwent "1"3"1I meta-iodobezylguanidine (MIBG) scan and bone scan. MIBG uptake was seen in the primary lesion in 11/12 patients. MIBG uptake in bones was seen in 3/12 patients. All bone lesions were concordant on MIBG and bone scan. Early response to chemotherapy was evaluated after two cycles using PET-CT. A 30% reduction in longest diameter was taken as cut-off value for response on CT based on the response evaluation criteria in solid tumors criteria. ...

347

Roentgenological analysis of sternocostoclavicular hyperostosis by computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Roentgenological analysis of the anterior chest wall was performed in twenty six patients with sternocostoclavicular hyperostosis. Initial hyperostotic change was seen at the first costosternal junction with ventral protrusion. Hyperostosis gradually developed around the first ribs, and irregular hyperostotic changes were also seen along the costoclavicular ligaments. Even in the final stage, however, sternoclavicular joint spaces were well preserved. These findings suggest that sternocostoclavicular hyperostosis is a disorder initiated around the costal cartilage including the periosteum and perichondrium, and that arthritis is not a condition stemming from that disorder.

1989-01-01

348

Rapid Tools for Joint Inversion and Imaging. Final report  

Energy Technology Data Exchange (ETDEWEB)

The activities and results of a Small Business Innovation Research Phase II project entitled ''Rapid Tools for Joint Inversion and Imaging'' are presented. Research and development on three-dimensional methods to recover distributions of material property values from sparse data are reported. Innovations using artificial neural networks and extended Kalman filtering are described. The report also covers investigations on upscaling and downscaling, segmentation for data processing, and applications to ground penetrating radar and geohydraulic tomography.

2000-08-02

349

Radiodiagnosis of Ewing's sarcoma of the rib in children  

International Nuclear Information System (INIS)

The results of the examination of 23 children with Ewing's sarcoma of the rib were analyzed: panoramic chest X-rays in 4 projections, spot radiographs of the robs, superexposed pictures, laterograms, urography, angiography, computerized tomography, and scanning of the skeleton. Causes of diagnostic errors made at the first consultation by a physician, were identified. Peculiarities of X-ray signs of tumors of this site in children were studied. Diagnostic difficulties in tumors complicated by pleurisy and in tumors of small sizes with extrapleural growth were shown. Inclusions in the extraoseous tumor component were noted in 8.7% of the cases.

350

New mass screening project for lung cancer with mobile spiral computed tomography (CT) and computed radiography (CR) in Ehime district  

Energy Technology Data Exchange (ETDEWEB)

To improve the detection rate of lung cancer, we have introduced low-dose CT and CR technique into a population-based annual mass screening. From December 1999, 3868 and 12618 individuals participated in this screening program with CT and with CR, respectively. Primary lung cancer was detected in 15 (0.39%) by CT and 8 (0.06%) by CR. This results show high detection rate of primary lung cancer as had been previously reported. (author)

2002-01-01

351

Involvement of the chest and abdominal wall as a rare manifestation in Hodgkin's disease  

Energy Technology Data Exchange (ETDEWEB)

Radiological findings of chest and abdominal wall involvement in Hodgkin's disease are reported. This manifestation was diagnosed in one patient in the primary staging and in two patients during the course of the disease. Typical radiological findings are soft tissue masses in the chest and abdominal wall, in two cases with continous tumor growth of enlarged mediastinal lymphnodes into the anterior chest wall. The axial computed tomography is the best method to evaluate the extent of chest and abdominal wall involvement in Hodgkin's disease.

1983-03-01

352

Integration of SPECT with CT to plan radiotherapy fields. n application to conformal irradiation for lung carcinoma  

International Nuclear Information System (INIS)

Single photon emission computed tomography (SPECT) of lung perfusions permits to map functioning lung parenchyma with higher sensitivity than CT. Delivering higher radiations doses it used to increase local control in lung carcinoma; this strategy is based on radiobiological and clinical studies. Lung parenchyma is a dose-limiting tissue in patients irradiated for lung cancer. Functional mapping based on SPECT and CT findings permits to design radiation beams such as to minimize irradiation of functioning lung.

1999-04-01

353

Hard X-ray phase imaging and tomography using a grating interferometer  

International Nuclear Information System (INIS)

An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.

2007-07-01

354

Gunshot wounds of abdomen detected at CT. Personal experience in 30 patients; Ferite da arma da fuoco dell'addome studiate con tomografia computerizzata: esperienza personale in 30 casi  

Energy Technology Data Exchange (ETDEWEB)

The paper investigates the yield and the role of the computerized tomography in diagnosing abdominal gunshot wounds, with their rich and varied radiological signs and associated injuries, and subsequently used in the diagnosis. [Italian] Scopo del lavoro e' riportare l'esperienza personale nell'uso della tomografia computerizzata per riconoscere le lesioni da arma da fuoco dell'addome e nelle fasi successive dell'approfondimento diagnostico.

1999-09-01

355

Design of a neutron radiography collimator system in a through beam port at the TRIGA reactor  

Energy Technology Data Exchange (ETDEWEB)

A neutron collimator system is being designed as part of a neutron imaging facility for computed tomography and real-time neutron radiography research at the through beam port of the University of Texas TRIGA reactor. Lack of sufficient information about collimator systems in a through port from the literature necessitated the use of Monte Carlo calculations using the MCNP code 3 to search for optimal design configuration and materials that maximize the thermal neutron intensity at the image plane while minimizing the fast neutrons and gamma radiation.

1996-12-31

356

Computerized tomography in the diagnosis and follow up in three observations of primitive suprasellar germinoma  

International Nuclear Information System (INIS)

Three cases of primitive suprasellar germinomas are reported: the tumors show typical clinical signs (diabetes insipidus, disfunctions), but CT findings are not so specific. It is very important to reach a correct diagnosis based on clinical and radiological findings, because of very high radiosensibility of the tumor. The accuracy of preoparative diagnosis has been enhanced by CT in addition to conventional neuroradiological examinations. Due to the possible risk of meningeal spreading following biopsy, some authors prefer to avoid biopsy and to treat directly the patient by radiotherapy; a rapid reduction of the tumor size at the dose of 30 Gy suggest a possible germinoma.

1986-01-01

357

Computer tomographic demonstration of so-called azygos continuation in the absence of the hepatic segment of the inferior vena cava  

International Nuclear Information System (INIS)

Dilatation of the azygos vein is usually due to increased pressure or flow, rarely is it diopathic. Another cause is so-called continuation of the azygos in cases of absence of the hepatic segment of the inferior vena cava. The method of choice for the investigation of azygos dilatation nowadays is computer tomotgraphy. Anomalies of the inferior vena cava can be recognised in this way unequivocally by a non-invasive method. Computer tomography frequently shows important additional abnormalities (e.g. situs inversus, polysplenia), since it demonstrates all organs situated in the plane of section. (orig.).

358

Computed Tomography of the cranio-cervical junction in rhematoid arthritis  

International Nuclear Information System (INIS)

Twenty rheumatoid arthritis (RA) patients with involvement of the cranio-cervical junction (CCJ) were given CT scan. In most cases the myelo-CT technique with the lumbar injection of small quantities of non-ionic contrast medium was adopted; CT easily diagnosed the horizontal and vertical dislocations on the CCJ, the bone strcture lesions and the inflammatory masses. A high frequency of medullary compressions was also found in these patients. Myelo-CT appears to be the technique of choice for the precise definition of the various factors responsible for the neurological complications found in RA of the CCJ.

1987-01-01

359

Breast imaging with a dedicated PEM  

International Nuclear Information System (INIS)

During the last decade there was a growing interest on the application of Positron Emission Tomography, PET, techniques to Breast Imaging. More recently, preliminary results suggested the use of dedicated devices to Breast Imaging using the same technique, the so-called Positron Emission Mammography cameras, PEM. In this article we review the arguments leading to a dedicated instrument. Based on these arguments we describe the concept of a PEM camera under development within the Crystal Clear Collaboration and the first results of its expected performance in terms of sensitivity and position resolution.

2004-07-11

360

Bilateral lipoma arborescens of the bicipitoradial bursa  

International Nuclear Information System (INIS)

A 37-year-old military mechanic presented to our institution with a chronic history of a slowly enlarging left elbow antecubital fossa mass. There was no history of other chronic illness or trauma. Magnetic resonance imaging (MRI) and excisional biopsy revealed fatty villi and synovial inflammation within the left bicipitoradial bursa, consistent with lipoma arborescens. Four years later the patient presented with a 6-month history of swelling at the antecubital fossa of the opposite elbow. Diagnostic computed tomography and MRI examinations were performed. The surgical and pathologic findings confirmed the imaging diagnosis of lipoma arborescens at the right bicipitoradial bursa. (orig.)

2002-11-01

361

Usefulness of Computed Tomography in pre-surgical evaluation of maxillo-facial pathology with rapid prototyping and surgical pre-planning by virtual reality  

International Nuclear Information System (INIS)

Purpose. To validate a protocol for creating virtual models to be used in the construction of solid prototypes useful for the planning-simulation of maxillo-facial surgery, in particular for very complex anatomical and pathologic problems. To optimize communications between the radiology, engineering and surgical laboratories. Methods and materials. We studied 16 patients with different clinical problems of the maxillo-facial district. Exams were performed with multidetector computed tomography (MDCT) and single slice computed tomography (SDCT) with axial scans and collimation of 0.5-2 mm, and reconstruction interval of 1 mm. Subsequently we performed 2D multiplanar reconstructions and 3D volume-rendering reconstructions. We exported the DICOM images to the engineering laboratory, to recognize and isolate the bony structures by software. With these data the solid prototypes were generated using stereolitography. To date, surgery has been ...

2005-11-01

362

The clinical application of positron emission tomography to colorectal cancer management  

International Nuclear Information System (INIS)

Colerectal cancer (CRC) is the second commonest cancer in the Western World. Successful treatment relies significantly on accurate detection and staging of primary disease as well as the early identification of the presence and extent of recurrence. Morphological imaging techniques, particularly computed tomography (CT), are well established and widely available to carry out these tasks in addition to predicting and monitoring response to therapy. This review analyses the current inadequacies for imaging CRC and critically assesses the potential role of functional imaging with positron emission tomography (PET). It was reviewed the current literature, to use the experience from the firs 1000 PET studies carried out at the institution and the perspective of surgical colleagues. It was found little evidence for the use of 2-["1"8F]fluoro-2-deoxy-D-glucose (FDG)-PET for screening asymptomatic individuals and current modalities appear better suited ...

2001-09-01

363

Reflection tomography using finite element method ray tracing  

Energy Technology Data Exchange (ETDEWEB)

The seismic reflection exploration technique which is one of the geophysical methods for oil exploration became effectively to image the subsurface structure with rapid development of computer. As a tool to perform seismic inversion, seismic forward modeling program using ray tracing should be developed. In this study, we have developed the algorithm that is to calculate the travel time of the complex geological structure using ray tracing by subdividing the geologic model into triangular element (finite element) having the constant velocity. We can analytically calculate Jacobian with some information by this current ray tracing. With this Jacobian, we will develop new algorithm which is to obtain geological properties and to image the subsurface. After subdividing subsurface into triangular element we shoot off the ray into subsurface by the Snell`s law. And then after taking the ray path which is similar to proper assumption we can calculate travel time. With this new ray tracing ...

1996-12-01

364

Neutron-computer tomography using real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10/sup 11/ m/(m/sup 2/-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83/sup 0/C +/- 8/sup 0/C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3/sup 0/ +/- 0.1/sup 0/ thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the simultaneous iterative reconstruction technique (SIRT) and the ...

1986-01-01

365

Neutron-computer tomography using real-time neutron radiography  

International Nuclear Information System (INIS)

A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10"1"1 m/(m"2-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83"0C +/- 8"0C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3"0 +/- 0.1"0 thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the simultaneous iterative reconstruction technique (SIRT) and the convolution method, were ...

1986-01-01

366

Computerized tomography-guided neurolytic splanchnic nerve block  

International Nuclear Information System (INIS)

Computerized tomography-guided neurolytic splanchnic nerve block is a technique for relieving abdominal cancer pain; the goal is the alcoholic neurolytic interruption of the sensitive structures in retroperitoneal space. Computerized tomography yields accurate anatomical detailing and the course for needle placement and alcohol spread. January, 1993, to July, 1996, twenty-one bilateral splanchnic nerve blocks were performed through the posterior access. Forty-eight hours after alcoholism. 14 patients (66%) had complete pain regression; 52% of the patients needed no analgesics for 6 to 54 days and only 9 patients (42%) needed another low opioid therapy. Complications included hypotension and diarrhea in all cases. One had a cardiac arrest and diet 8 days after the procedure. There were no other complications. The whole procedure usually lasted 60 min (range: 45 to 90 min). Splanchnic nerve neurolysis is a useful treatment in the patients with ...

1997-01-01

367

Computerized Tomography-guided fine-needle biopsy of peripheral pulmonary nodules < 2 cm in diameter  

International Nuclear Information System (INIS)

The authors investigated the role of Computerized Tomography in guiding fine needle biopsy (FNB) in small (2 2 cm in diameter for CT-guided FNB sensitivity, specificity and diagnostic accuracy. Cytologic specimens were positive for malignancy in 40/52 cases (76.9%) and negative in 12 (23.1%). Clinical-surgical follow-up confirmed all the positive cytologic findings (40 cases), while 2 of the extant 12 cases were false negatives (95.20% sensitivity, 100% specificity and 96.15% diagnostic accuracy). 158 of 195 nodules > 2 cm in diameter and with clinical surgical follow-up (81.3%) were positive for malignancy and 34 were negative (17.43%) (98.75% sensitivity, 97.14% specificity and 98.46% diagnostic accuracy). Pneumothorax occurred in 33 patients (16.5%) with nodules > 2 cm in diameter as a complication of biopsy. Hemoptysis occurred in 15 patients (7.5%). In the whole group of lung lesions, the complications were pneumothorax in 80 patients (4.1%), hemoptysis ...

368

Waves in pulsar winds  

International Nuclear Information System (INIS)

The radio, optical, x-ray and gamma-ray nebulae that surround many pulsars are thought to arise from synchrotron and inverse Compton emission. The energy powering this emission as well as the magnetic fields and relativistic particles are supplied by a 'wind' driven by the central object. The inner parts of the wind can be described using the equations of MHD, but these break down in the outer parts, when the density of charge carriers drops below a critical value. This paper reviews the wave properties of the inner part (striped wind), and uses a relativistic two-fluid model (cold electrons and positrons) to re-examine the nonlinear electromagnetic modes that propagate in the outer parts. It is shown that in a radial wind, two solutions exist for circularly polarized electromagnetic modes. At large distances one of them turns into a freely expanding flow containing a vacuum wave, whereas the other decelerates, corresponding to a confined flow.

2010-12-01

369

The segmental gastrocnemius muscles' flap: A cadaveric study  

British Library Electronic Table of Contents (United Kingdom)

The aim of this study was to evaluate the feasibility of splitting each head of the gastrocnemius muscle into two segments. This prospective study was conducted on 35 fresh cadavers with injection of radio-opaque contrast material in the popliteal artery. Seventy medial gastrocnemius and 70 lateral gastrocnemius muscle specimens were obtained. Gastrocnemius intramuscular arterial anatomy was analysed by using the digital X-ray technique. The most common vascular pattern found in this study was both bellies supplied by individual sural arteries, which shows distal bifurcation. The medial sural artery always showed bifurcation in the medial gastrocnemius muscle in both lower limbs, whereas this bifurcation of the lateral sural artery was present in only 87% cases and 13% of cases showed a si...

2011-01-01

370

The content of L-carnitine in meat after different methods of heat treatment  

British Library Electronic Table of Contents (United Kingdom)

Purpose - The objective of this study is to examine the effects of pan-frying, boiling and cooking in a microwave on the amount of L-carnitine in meat and to look at its distribution in the surrounding fluid after food processing. Design/methodology/approach - Total carnitine, free carnitine and acylcarnitines were determined in meat samples from beef, pork and poultry (including ostrich) and in a liver sample from beef. The measurements were carried out before and after the specimens were subjected to different heat treatments. A radio-enzymatic assay was used for measurement of L-carnitine. Results are expressed per 100 gram dry matter and per 100 gram wet weight. Findings - Except for pan-frying, virtually no losses of carnitine occurred during the different procedures of heat treatment...

2011-01-01

371

Temperature problems in mine rescue  

Energy Technology Data Exchange (ETDEWEB)

Describes temperature and humidity sensing devices used in mine rescue operations. Chemical indicators use chemical substances that melt at predetermined temperatures and display the actual temperature in the range of 40-50 C. Electronic temperature monitoring devices release acoustic signals as soon as a temperature of 40 or 45 C has been exceeded. A more recent piece of equipment combines the ULR rescue communication set with remote temperature sensing. A digital meter that measures temperature and humidity in the range of -100 to +200 C and 3 to 98% respectively has also been developed. The Central Mine Rescue Station in Bytom, Poland has developed equipment that permits body temperature and pulse rate of a rescuer to be measured and transmitted by radio over a distance of up to 50 m. Safe threshold values can be set for each individual rescuer.

1990-08-01

372

Synthesis and biodistribution of "9"9"mTc-peptides conjugated adenine as tumor imaging agents  

International Nuclear Information System (INIS)

Two peptide ligands conjugated adenine, [9-N-(tritylmercapto acetyl diglycyl aminoethyl) adenine, Tr-MAG_2-Ade] and [9-N-(tritylmercapto acetyl triglycyl aminoethyl) adenine, Tr-MAG3-Ade], are synthesized and labeled with "9"9"mTc by directly labeling method. The stability of "9"9"mTc-MAG_2- adenine and "9"9"mTc-MAG_3-adenine in vitro is measured. The uptake radios of tumor to muscle at 3h post-injection are 5.70 and 4.92, respectively. The biodistribution and scintigraphic imaging studies show that the two complexes have high localization in tumor and high contrasted tumor images can be obtained, which suggest their potential utility as tumor imaging agents. But the high radioactivity of abdomen could prevent the tumor imaging in this area. (author)

2007-07-01

373

Seasonal variation measurements of radon levels in caves using SSNTD method  

Energy Technology Data Exchange (ETDEWEB)

The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm{sup -3}, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.

2008-08-15

374

Seasonal variation measurements of radon levels in caves using SSNTD method  

International Nuclear Information System (INIS)

The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm-3, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.

2008-08-01

375

Search for tachyons associated with EAS at energies E>=3x10"1"6eV  

International Nuclear Information System (INIS)

This paper describes an experiment which has been performed with a somewhat different philosophy in its approach as compared to previous work. (a) The trigger threshold energy was increased by more than a factor of ten on previous experiments reducing the dilution effect of many lower energy showers known not to produce tachyons. 1673 shower were recorded. (b) The exposure time was made longer than previous experiments in order to obtain a reasonably large statistical sample at the higher threshold. Observations were made between February 1979 and June 1980, the total live time being 9768 hours. (c) Records of the detector output amplitude for the 480#mu#s lead time were integrated point by point as is sometimes done in radio astronomy, this gives the integrated energy deposition within the detector.

376

Satisfying story of how it all began  

Energy Technology Data Exchange (ETDEWEB)

{sup N}ow this 'Big Bang' idea seemed to me to be unsatisfactory...for it is an irrational process that cannot be described in scientific terms.' With this rather derisory remark (or at least so intended) in a 1950 radio broadcast, Fred Hoyle named the theory that rivalled his steady-state theory. The Big Bang has subsequently become the dominant paradigm in attempts to understand our universe. It is also one of the dominant ways in which popular-science writing seeks to persuade people to part with their cash. Simon Singh has rapidly made a name for himself as one of the leading popularizers of science, with his previous books Fermat's Last Theorem and The Code Book bringing accessible science to a wide audience . Big Bang brings him to a much busier marketplace, where he must compete both with other science writers and with working scientists. (U.K.)

2004-12-01

377

Recent advances in silicon-germanium alloy technology and an assessment of the problems of building the modules for a radioisotope thermoelectric generator  

International Nuclear Information System (INIS)

This paper reviews the state of the art of silicon-germanium technology and assesses the problems of building thermoelectric modules in Europe, based upon silicon-germanium alloys, for use in multihundred watt radio-isotope thermoelectric generator. The generator developed in the United States for the International Solar Polar mission has been used as a reference system. The essential features of an alternative system, which employs thermocouples fabricated from improved silicon-germanium alloys based upon a design by the Fairchild Space and Electronics Company, is also described. It is concluded that although the fabrication of reliable electrical contacts will present a major problem, the technology is available in Europe to build thermoelectric modules similar to those developed for the International Solar Polar mission. (orig.).

378

Radio cellular phones and health: Up-to-date research on human health; Radiotelephones cellulaires et sante: mise au point des recherches portant sur la sante chez l'homme  

Energy Technology Data Exchange (ETDEWEB)

Cellular telephones emit a radiofrequency electromagnetic field, part of which is absorbed in the user's head. Many studies have been conducted to look for their possible health hazard to human, at the experimental, epidemiological or clinical level. After a short recall on dosimetry, the author describes the state-of-the art about harmful and irreversible effects, up to now not confirmed, and about some benign symptoms which look absolutely actual. A causal relationship of the electromagnetic field on these benign symptoms is however not proven; other, studies are running to evaluate their possible long-term consequences. Interferences with cardiac pacemakers can easily be avoided by holding the telephone handset farther than 10 cm. (author)

1999-12-01

379

Radiation therapy and Ewing's sarcoma in childhood  

International Nuclear Information System (INIS)

Despite high local control rate in Ewing's sarcoma the exact indication of radiation therapy is still controversial as well as the choice of the target volume and the optimal dose of radiation. The importance of the quality of radiotherapy has been stressed in recently published data and has shown a significant impact on long term local control with adequate radiation therapy. The dramatic improvement of precision allowed by the conformal therapy and three dimensional dosimetry allow to expect a decrease of late effects expected for second malignancies. However, late sequelae and radio-induced osteosarcoma still remain the major side effects after radiotherapy. The authors discuss the results of the main trials on Ewing's sarcoma on the choice of dose and target volume. Surgery is still the preferred choice for small tumors if the foreseen outcome is identical. (authors). 28 refs.

380

Radiation protection - an overview of the concept for radiation protection at work and the concept for environmental radiation protection  

International Nuclear Information System (INIS)

This book gives an overview of the entire field of radiation protection with the subject areas radioactivity, X-rays, UV radiation, laser beams and high-frequency electromagnetic fields. It deals graphically with the most important physical notions, the incidence, origin, properties and biological effects of types of radiation, administrative and practical protection measures and the code of rules governing them. Apart from fundamentals of radiation protection the emphasis on the following: natural radiation exposure, radiation exposure to radon, disaster relief plans in the environment of nuclear plant, the precautionary radiation protection system evolved after Chernobyl, radiation exposure through UV radiation devices, radio, RF communication, radar, microwave ovens and high-voltage transmission lines as well as computer work-places. (orig.).

1993-01-01

381

RXTE observations of Cas A  

International Nuclear Information System (INIS)

Rossi X-ray Timing Explorer (RXTE) observations of the bright supernova remnant Cas A have revealed a hard power law component above 10 keV in addition to two thermal components inferred from ASCA measurements of the many line centroids from low-Z elements. The power law can be shown to be consistent with synchrotron emission from radio to hard x-rays by electrons of up to 4 x 10"1"3 eV. Measurement of the 1157 keV line by CGRO from "4"4Sc in the chain of decay of "4"4Ti predicts that the two "4"4Ti lines at 68 and 78 keV should appear at the CGRO intensity. RXTE has placed upper limits on such lines that are marginally consistent with the CGRO measurement. Implications of these results on sites for cosmic ray acceleration and nucleosynthesis are discussed.

1999-01-01

382

Quantification of the thrombogenicity of Dacron aortic prostheses  

International Nuclear Information System (INIS)

Eight patients with double-velour Dacron aorto-femoral grafts implanted for 2-60 months were studied. Indium-111-labelled platelets were found to have a shortened mean platelet lifespan (MPLS) of 138 +- 32 hours compared with the normal platelet lifespan of 224 +- 23 hours. Labelled platelets accumulated on all grafts, irrespective of graft age, to a maximum of 1,80 +- 0,83% of whole body radioactivity; thereafter graft radio-activity decreased. This suggests that platelets on the graft are in dynamic equilibrium with those in the circulation. Platelets may be lost from the graft by embolization or radioactivity may be released because of platelet lysis. Although MPLS may depend on the age and surface area of the graft, concomitant arterial disease probably also contributes to the shortened MPLS.

383

Present status of free electron laser and its utilization research facilities  

International Nuclear Information System (INIS)

The historical back ground of free electron laser (FEL) and the present status of development and utilization research of FEL facilities in the world are explained. Eight facilities such as Stanford Univ., UCSB, Duke Univ., Vanderbilt Univ., LANL AFEL (USA), FOM FELIX (Netherlands), N-lands LURE CLIO (France) and FELI (Japan) can be used. The principle of FEL generation process is that free electrons move in a zigzag direction to generate radio waves which interfere with each other to become monochromatic light and then free electron laser. The benefits of FEL, quality of electron beam, limit of wave length of FEL, problems and development of utilization technologies of FEL are explained. (S.Y.)

1997-11-01

384

Preparation and dosimetry of radiotherapeutic particles for arthropaties; Preparacion y dosimetria de particulas radioterapeuticas para artropatias  

Energy Technology Data Exchange (ETDEWEB)

It was developed a new formulation of macro aggregates of Samarium 153 ({sup 153} Sm-MH) for the arthropaties treatment. The radio pharmaceutic was prepared by reaction of Samarium 153 chloride (SmCl{sub 3}) in aqueous environment with sodium boron hydride in NaOH 0.5 N. The microscopic analysis shown that the particles have an average size of 4% m (range 1-14 {mu} m). The velocity of sedimentation was 0.008 cm/min with high stability in vitro in human serum. The biological studies in healthy rabbits, shown that the complex is retained inside the articulation still eight days after of the administration of the radiopharmaceutical. Likewise, it is presented the data of absorbed dose in the different target organs, which was determined by thermoluminescent dosimetry (TLD) through the use of a REMCAL phantom (radiation equivalent manikin calibration). (Author)

1999-07-01

385

Premature Failure of a Riata Defibrillator Lead Without Impedance Change or Inappropriate Sensing: A Case Report and Review of the Literature  

British Library Electronic Table of Contents (United Kingdom)

Premature Failure of a Riata Defibrillator Lead. A 63-year-old woman with a St. Jude Medical Riata 1570 right ventricular lead complained of intermittent hiccups 2 months after implant. Interrogation revealed elevated pacing threshold and diaphragmatic stimulation. Pacing and shock lead impedances remained stable. No inappropriate sensing was noted. Fluoroscopic examination of the lead revealed a thin radio-opaque wire seen between the 2 defibrillator coils away from the main body of the lead. After extraction, a tear in the insulation of the lead was noted allowing the inner wire to protrude. This case illustrates a novel mechanism of insulation failure without inappropriate sensing or impedance change.-(J Cardiovasc Electrophysiol, Vol. 22, pp. 1070-1072, September 2011)

2011-01-01

386

Opportunistic Cooperation in Cognitive Femtocell Networks  

CERN Document Server

We investigate opportunistic cooperation between unlicensed secondary users and legacy primary users in a cognitive radio network. Specifically, we consider a model of a cognitive network where a secondary user can cooperatively transmit with the primary user in order to improve the latter's effective transmission rate. In return, the secondary user gets more opportunities for transmitting its own data when the primary user is idle. This kind of interaction between the primary and secondary users is different from the traditional dynamic spectrum access model in which the secondary users try to avoid interfering with the primary users while seeking transmission opportunities on vacant primary channels. In our model, the secondary users need to balance the desire to cooperate more (to create more transmission opportunities) with the need for maintaining sufficient energy levels for their own transmissions. Such a model is applicable in the emerging area of cognitive ...

2011-01-01

387

Nigeria's radioactive waste management policy and strategy document  

International Nuclear Information System (INIS)

Radioactive waste for legal and regulatory purposes may be defined as material that contains or is contaminated with radio-nuclides at concentrations or activities greater than clearance levels as established by the regulatory body, and for which no use is foreseen. Safe management of radioactive waste is essential to ensure protection of humans and environment. Radioactive waste management policy is a guideline for the safe management of radioactive waste. It expresses the commitment of the country towards the goal. Government should initiate investigation into best long-term option for management of spent nuclear fuels. Process of selecting option and eventual site should involve comprehensive public participation within set time frames (with deep geological disposal as preferred management option).

2009-07-14

388

Neutron star evolution and emission  

Science.gov (United States)

This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The authors investigated the evolution and radiation characteristics of individual neutron stars and stellar systems. The work concentrated on phenomena where new techniques and observations are dramatically enlarging the understanding of stellar phenomena. Part of this project was a study of x-ray and gamma-ray emission from neutron stars and other compact objects. This effort included calculating the thermal x-ray emission from young neutron stars, deriving the radio and gamma-ray emission from active pulsars and modeling intense gamma-ray bursts in distant galaxies. They also measured periodic optical and infrared fluctuations from rotating neutron stars and search for high-energy TeV gamma rays from discrete celestial sources.

1997-08-01

389

Measurements to be taken after a nuclear accident in order to limit the uptake of radionuclides from the soil by nutrition crops  

International Nuclear Information System (INIS)

By the department Radio-ecology of the Laboratory for Radiation Research, in the period 1981 up to 1989 inclusive, the transfer has been studied, from soil to plant, of a number of important activation and fission products, originating in the nuclear-power production in nuclear power plants. The purpose of this study was twofold: on the one side the quantification of this transfer for various agrarian systems and on the other side to find out in how far, after an accidental contamination, certain agriculture activities can influence essentially the transfer and subsequently the radiation burden for the population. Emphasis lay, the last years, in particular upon this second aspect. The results of this study form essential basic data for diffusion models for radioactive materials which, in turn, are important in estimating the effects of measures. (author). 6 refs.; 4 figs.

390

Magnetic layer formation on plasma nitrided CoCrMo alloy  

British Library Electronic Table of Contents (United Kingdom)

In this study structural and magnetic character of the expanded austenite phase (gN) layer formed on a medical grade CoCrMo alloy by a low-pressure Radio-Frequency plasma nitriding process was investigated. The formation of the expanded austenite phase is facilitated at a substrate temperature near 400^oC for 1, 2, 4, 6 and 20h under a gas mixture of 60% N2-40% H2. The magnetic state of the gN layers was determined by a surface sensitive technique, magneto-optic Kerr effect (MOKE), and with a scanning probe microscope in magnetic force mode (MFM). Strong evidence for the ferromagnetic nature of the gN-(Co,Cr,Mo) phase is provided by the observation of stripe domain structures and the hysteresis loops. The ferromagnetic state for the gN phase observed here is mainly linked to large lattice ...

2011-01-01

391

Irradiation of human insulin in aqueous solution, first step towards radiosterilization  

British Library Electronic Table of Contents (United Kingdom)

The degradation of irradiated human insulin in aqueous solutions was investigated in order to protect the protein against ionizing radiation. The influence of the drug concentration, excipients and irradiation temperature were studied.Aqueous solutions at pH 2 were irradiated by gamma rays or by accelerated electrons. Two different high-performance liquid chromatography (HPLC) methods were used: reverse-phase high-performance liquid chromatography (RP-HPLC)/UV and size exclusion liquid chromatography (SEC/UV) to investigate both the fragmentation and the formation of higher molecular weight proteins.In solution without excipients irradiated at ambient temperature at 10kGy, the loss of human insulin is almost complete. Addition of radio-protecting excipients (free radicals scavengers) and c...

2007-01-01

392

Investigation of methods for improving models of ionospheric plasma-density irregularities and radio-frequency scintillation. Technical report  

Energy Technology Data Exchange (ETDEWEB)

Many modern military systems used for communications, command and control, navigation, and surveillance depend on reliable and relatively noise-free transmission of radiowave signals through the earth's ionosphere. Small-scale irregularities in the ionospheric density can cause severe distortion, known as radiowave scintillation, of both the amplitude and phase of these signals. The WBMOD computer program can be used to estimate these effects on a wide range of systems. The objective of this study is to investigate improvements to the WBMOD model based on extensive data sets covering both the equatorial and high-latitude regimes. This report summarizes the work completed during the second year, which include completion of the new models for the equatorial region and initial development of models for the high latitude (auroral and polar cap) region.

1993-11-01

393

Interpolating atmospheric water vapor delay by incorporating terrain elevation information  

British Library Electronic Table of Contents (United Kingdom)

In radio signal-based observing systems, such as Global Positioning System (GPS) and Interferometric Synthetic Aperture Radar (InSAR), the water vapor in the atmosphere will cause delays during the signal transmission. Such delays vary significantly with terrain elevation. In the case when atmospheric delays are to be eliminated from the measured raw signals, spatial interpolators may be needed. By taking advantage of available terrain elevation information during spatial interpolation process, the accuracy of the atmospheric delay mapping can be considerably improved. This paper first reviews three elevation-dependent water vapor interpolation models, i.e., the Best Linear Unbiased Estimator in combination with the water vapor Height Scaling Model (BLUE?+?HSM), the Best Linear Unbiased Es...

2011-01-01

394

Follow-up and diagnosis of recurrences after radio-chemotherapy of malignant head and neck tumors  

International Nuclear Information System (INIS)

339 CT und 95 MRT examinations in 210 partients were evaluated retrospectively to determine the value of CT and MRT for follow-up of head and neck tumors and for diagnosing recurrences. Semi-quantitative evaluation of tumor extent during and after radiotherapy showed advantages for MRT since changes induced by treatment, particularly oedema, produced less contrast loss in the images. CT had a sensitivity of 81% for the recognition of recurrences; this was 92% for MRT. Specificity for CT was 76% and for MRT 86%. Concerning the reliability of individual diagnostic criteria, space occupying lesions were the most valuable in CT diagnosis. For MRT, space occupying lesions and infiltration into neighbouring structures were of equal value. Because of differences in the nature of the signals, MRT proved better than CT in characterising recurrent masses and this improved the differentiation between scarring and local tumour recurrence. (orig.).

395

Explosives detector  

Energy Technology Data Exchange (ETDEWEB)

An apparatus for non-invasively inspecting an object, such as an item of luggage, for explosives material is described. It comprises a multi-channel thermal neutron inspection system having a plurality of neutron irradiation chambers. Simultaneous operation of several channels increases the maximum system throughput several times. Each chamber has a lithium neutron source which is stimulated to neutron production by a proton beam. Beam switching magnets are energised by pulsing to divert a common proton beam to each source in turn. The initial beam is generated by a radio frequency quadrupole accelerator. The advantages of this system are very low residual source activity and controllable neutron production thereby minimising safety hazards. The irradiation chamber may contain several different gamma ray detectors to identify the elements present in explosives material. In addition, a neutron radiography imaging means may be employed to identify the presence of ...

1991-10-02

396

Effects of sputtering pressure on the characteristics of lithium ion conductive lithium phosphorous oxynitride thin film  

British Library Electronic Table of Contents (United Kingdom)

Lithium phosphorous oxynitride(Lipon) thin films as a lithium ion conductive electrolyte were prepared by radio frequency reactive sputtering in N2 plasma. The properties of the amorphous Lipon solid electrolyte were investigated as a function of N2 pressure during reactive sputtering. The ionic conductivity and the electrochemical stability of Lipon thin films improved drastically as the N2 pressure decreased. The ionic conductivity closed to 10?6 S cm?1 and obtained a stability window of 1.0?5.0 V with an N2 pressure of 5 mTorr, where the number of nitrogen bonds between the phosphate groups were more than those formed at higher pressure. It was possible to fabricate the Li//LiCoO2 complete thin film battery using this Lipon solid electrolyte, which exhibited excellent discharge characte...

2006-01-01

397

Beam Profile Measurement and its Application to Calculate Beam Emittance Using Wire Scanner for the PEFP 20MeV linac  

International Nuclear Information System (INIS)

A 20-MeV proton accelerator is developed by Proton Engineering Frontier Project (PEFP) at Korea Atomic Energy Research Institute (KAERI). The 20MeV accelerator consists of 50keV proton injector, 3MeV RFQ (Radio frequency Quadrupole), 20MeV DTL (Drift Tube Linac) and 20MeV beam line. The beam profile was measured at the end of the 20MeV beam line with wire scanner. Moreover the beam emittance was calculated from the quad scan method using beam line quadrupole magnets. In this paper, the beam profile measurement results are presented and the emittance measurement from the quad scan method is discussed

2010-10-01

398

Applied geodesy  

Energy Technology Data Exchange (ETDEWEB)

This volume is based on the proceedings of the CERN Accelerator School's course on Applied Geodesy for Particle Accelerators held in April 1986. The purpose was to record and disseminate the knowledge gained in recent years on the geodesy of accelerators and other large systems. The latest methods for positioning equipment to sub-millimetric accuracy in deep underground tunnels several tens of kilometers long are described, as well as such sophisticated techniques as the Navstar Global Positioning System and the Terrameter. Automation of better known instruments such as the gyroscope and Distinvar is also treated along with the highly evolved treatment of components in a modern accelerator. Use of the methods described can be of great benefit in many areas of research and industrial geodesy such as surveying, nautical and aeronautical engineering, astronomical radio-interferometry, metrology of large components, deformation studies, etc.

1987-01-01

399

Analysis by radio-gaschromatography of volatile aldehydes produced by the linoleic acid oxidation of soya- and oats-lipoxygenase  

International Nuclear Information System (INIS)

Soya- and oats-lipoxygenase (E.C. 1.13.1.13) are incubated by "1"4C-marked linoleic acid. The volatile aldehydes arising thereby are isolated. The activity of the components separated by gaschromatography is written down by a printing indicator and the impulses/min are registered and printed out by a ratemeter. Thus the aldehydes which are produced by the enzymatic oxydation with lipoxygenase from the molecule of the linoleic acid can be determined. The composition of the mixture of aldehydes is calculated in mol-% from the measured impulses for peak. A possible origin of pathway is indicated for the main reaction products hexanal (soyalipoxygenase) and non-trans-2-enal (oats-lipoxygenase). (orig.).

400

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

International Nuclear Information System (INIS)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. (authors)

2008-05-01

401

A study on rf plasma nitriding at a constant power in different H_2-N_2 mixtures at different temperatures  

International Nuclear Information System (INIS)

Austenitic stainless steel AISI 304 has been nitrided by radio frequency (rf) plasma containing various nitrogen-hydrogen gas mixtures, in order to study the effect of hydrogen on structure and magnetic properties of the formed compound layer. The thermal temperature has been measured at the vicinity of the samples. The compound layer thus produced has been characterized using, X-ray diffractometer and vibration sample magnetometer. Providing the total pressure of nitrogen and hydrogen is held constant, the addition of hydrogen up to 50% gives new structural phases. The magnetization values of the plasma treated samples are strongly dependent on the percentage of H_2 in the gas phase. An excessive amount of hydrogen (#approx#75%) on the other hand, retards the nitriding process. The surface temperature of the sample and plasma condition is crucial factors for nitriding process.

2006-04-15

402

A radiation monitoring system for nuclear fusion devices  

International Nuclear Information System (INIS)

Fusion device produces high-level neutrons and #gamma#-rays, which would hazard the safety of the public and workers if the doses would be higher than the regulatory limits because of leakage from the bio-shielding and skyshine. It is essential to monitor the radiation doses in the workshop and the enumerative around fusion devices. A radiation monitoring system (RMS) for full (near and far) areas around a nuclear fusion device has been designed and developed, which can achieve the monitoring and controlling of radiation doses in the workshop area by using the Controller Area Network (CAN), in the institution area by using the Bluetooth Ad hoc network based on a new tree topology formation and routing protocol and in a long range environment by using the General Packet Radio Service (GPRS) network. (authors)

2005-12-01

403

A proposed linac cavity rf drive system for the Los Alamos extreme ultraviolet free-electron laser  

Energy Technology Data Exchange (ETDEWEB)

Since 1979, scientists and engineers at the Los Alamos National Laboratory have designed, constructed, and operated a radio-frequency (RF) linac free-electron laser (FEL) at wavelengths from 9 to 45 /mu/m. Coupled with success of other research centers investigating wavelengths from the visible to far-infrared, Los Alamos is now proposing a vacuum-ultraviolet and soft x-ray (referred to henceforth as extreme ultraviolet, (XUV)) FEL oscillator/Self-Amplified Spontaneous Emission amplifier with beam energies ranging from 100 MeV to 1 GeV. This paper will focus on the first milestone of the proposed Los Alamos XUV project, i.e., a 250-MeV linac with approximately 50 mA of average current, producing photons with wavelengths below 1000 /angstrom/. 3 refs., 3 figs.

1989-01-01

404

A program for passively tracking a target using an array of sensors  

Energy Technology Data Exchange (ETDEWEB)

The problem of passively tracking a moving signal source has importance in a variety of applications such as radar, sonar, seismology, and radio astronomy. In many applications, only limited information is available about the signal source. It will be assumed here that only the signals which are detected by the sensors and the velocity of the source signal are known. The objective of this document is to present a program which passively tracks a target using an array of sensors. This program is available in MATLAB, version 3.5. The algorithm which is implemented consists of three main parts: time delay estimation, passive localization, and data post processing. Each of these parts are discussed, and the mathematical foundation for their solution given. Following, this the organization of the program is presented, and an example of its usage is given.

1993-01-01

405

A nanosized silicon thin film as high capacity anode material for Li-ion rechargeable batteries  

Energy Technology Data Exchange (ETDEWEB)

Silicon thin film with thickness in range 1000-5300 A deposited on rough Cu foil by a radio frequency magnetron sputtering is used as anode materials for Li-ion rechargeable batteries. The SEM, XRD and TEM analysis reveals that the Si thin film has a floccular nano-sized multi-crystalline structure. Li ions insertion/extraction evaluation is performed mainly with constant current charge/discharge cycling and cyclic voltammetry (CV) at room temperature. The cycleability and reversible discharge capacity are found to depend on the film thickness, and thinner films give larger accommodation capacity. A 3120 A Si film provides a reversible specific capacity over 3500 mA hg{sup -1} with excellent cycleability under 0.5 C charge/discharge rate.

2006-07-15

406

Transluminal radio-frequency thermal ablation using a stent-type electrode: an experimental study  

Energy Technology Data Exchange (ETDEWEB)

To assess the feasibility of transluminal radiofrequency thermal ablation using a stent-type electrode and to determine, by means of in-vivo and in-vivo animal studies, the appropriate parameters. In-vivo: the radiofrequency electrode used was a self-expandable nitinol stent with 1cm insulated ends. A stent was placed in the portal vein of bovine liver, and ablations at target temperatures of 70, 80, 90, and 100 .deg. C were performed. Ablated sizes were measured longitudinally. In vivo: four mongrel dogs were anesthetized, and a stent was inserted in the common bile duct under fluoroscopic guidance through an ultrasound-guided gall bladder puncture site. The ablation temperature was set at 80 .deg. C, and each dog underwent proximal and distal esophageal ablations lasting 12 minutes. They were sacrificed immediately. In-vivo: ablated sizes showed significant correlation with target temperatures (r>0.04; p<0.05). Although most lesions were fusiform, dumbbell-shaped ...

2003-06-01

407

Gamma-ray pulse height spectrum analysis on systems with multiple Ge detectors using a spectrum summing  

Energy Technology Data Exchange (ETDEWEB)

A technique has been developed at the Idaho National Engineering Laboratory to sum high resolution gamma-ray pulse spectra from systems with multiple Ge detectors. Lockheed Martin Idaho Technologies Company operates a multi-detector spectrometer configuration at the Stored Waste Examination Pilot Plant facility which is used to characterize the radio nuclide contents in waste drums destined for shipment to Waste Isolation Pilot Plant. This summing technique was developed to increase the sensitivity of the system, reduce the count times required to properly quantify the radionuclides and provide a more consistent methodology for combining data collected from multiple detectors. In spectrometer systems with multiple detectors looking at non homogenous waste forms it is often difficult to combine individual spectrum analysis results from each detector to obtain a meaningful result for the total waste container. This is particularly true when the counting statistics in ...

1997-05-01

408

17- and 24-GHz observations of southern pulsars  

Science.gov (United States)

We present observations of PSRs J0437-4715, J0738-4042, J0835-4510, J0908-4913, J1048-5832, J1622-4950, J1644-4559, J1721-3532 and J1740-3015 at 17 GHz using the Parkes radio telescope. All nine were detected at 17 GHz, additionally, we detected PSR J0835-4510 and J1622-4950 at 24 GHz. Polarization profiles of each pulsar and the variation with frequency are discussed. In general, we find that the highly polarized edge components of young pulsars continue to dominate their profiles at 17 GHz. Older pulsars (?105 yr) appear to be almost completely depolarized. Our detection of PSR J0437-4715 is the highest frequency observation of a millisecond pulsar to date, and implies a luminosity at 17 GHz of 14 ?Jy kpc2, and a mean spectral index of 2.2. We find that the spectral index of the magnetar PSR J1622-4950 is flat between 1.4 and 24 GHz, similar to the other known radio magnetars XTE J1810-197 and 1E 1547.0-5408. The profile is similar to that ...

2011-06-01

409

Multi-Phase Fracture-Matrix Interactions Under Stress Changes  

Energy Technology Data Exchange (ETDEWEB)

The main objectives of this project are to quantify the changes in fracture porosity and multi-phase transport properties as a function of confining stress. These changes will be integrated into conceptual and numerical models that will improve our ability to predict and optimize fluid transport in fractured system. This report details our progress on: (a) developing the direct experimental measurements of fracture aperture and topology and fluid occupancy using high-resolution x-ray micro-tomography, (b) counter-current fluid transport between the matrix and the fracture, (c) studying the effect of confining stress on the distribution of fracture aperture and two-phase flow, and (d) characterization of shear fractures and their impact on multi-phase flow. The three-dimensional surface that describes the large-scale structure of the fracture in the porous medium can be determined using x-ray micro-tomography with significant accuracy. Several ...

2005-12-07

410

Uranium Mass and Isotopic Analysis. A new drum tomographic gamma scanning system  

Energy Technology Data Exchange (ETDEWEB)

The NIS-6 group at Los Alamos National Laboratory pioneered the development of Tomographic Gamma Scanning and continue to improve its utility in real measurement situations. Building on this experience we report the development of a state of the art TGS system suitable for industrial applications. The image reconstruction and visualization software has been integrated into the familiar Canberra NDA2000 software suite which also handles all other aspects of the data acquisition and management. In this paper we describe the salient design and performance parameters of the system. The application of gamma-ray tomography to safeguards for improved assay accuracy and knowledge confirmation is discussed. In particular we compare and contrast the relative merits of this TGS and a traditional Segmented Gamma Scanner and illustrate how the 3-D visualization of the TGS image can provide valuable additional information.

2003-05-01

411

Tracheal compression by mediastinal masses in children: CT evaluation  

Energy Technology Data Exchange (ETDEWEB)

Chest computed tomography (CT) was valuable in detecting extrinsic tracheal compression by mediastinal masses in two pediatric patients. This prompted an independent evaluation by CT of 14 children with masses involving the middle mediastinum and possible intrathoracic tracheal narrowing. Computer programs permit precise calculation of tracheal cross-sectional areas. Any apparent decrease in tracheal area may be compared with CT-derived data in normal children. Chest CT not only demonstrates the presence of extrinsic airway compression in pediatric patients with mediastinal masses, but also is capable of precisely measuring the extent of this narrowing. This method identifies children at potential risk for respiratory compromise and may aid in subsequent therapy.

1983-10-01

412

The use of magnetic resonance imaging for diagnosis and staging of renal cell carcinoma  

International Nuclear Information System (INIS)

The use of magnetic resonance imaging for diagnosis and the preoperative staging of renal cell carconoma was evaluated in 79 patients with 88 tumors. Gradient-echo and spin-echo images before and after intravenous administration of Gadolinium DTPA were compared with the results of computed tomography (CT) and histologic staging. The two imaging techniques had comparable results: T-stage was predicted correctly with CT in 78%.4% and with MRI in 84.0% of the cases, while the N-stage was accurately assessed in 81.8% and 79.5%, respectively. MRI had some advantages in diagnosing perirental tumor spread and in excluding an infiltration beyond Gerota's fascia. Therefore, MRI is a true alternative to CT for staging large renal cell carcinomas and especially for patients with contraindications for iodinated contrast agents. (orig.).

413

The use of healthy volunteers instead of patients to inform drug dosing studies: a [11C]raclopride PET study  

British Library Electronic Table of Contents (United Kingdom)

Rationale Receptor occupancy study has been performed to evaluate pharmacokinetic profiles in new antipsychotic drug development. While these findings highlight the value of positron emission tomography (PET) for dose-finding study, what is unclear is if it is necessary to conduct these studies in patients with schizophrenia or whether studies in healthy volunteers are adequate. Objectives To determine if it is necessary to conduct dopamine receptor occupancy studies in patients with schizophrenia or whether studies in healthy volunteers are adequate for dose-finding study, we compared the concentration?occupancy relationship in terms of EC50 between patients and healthy volunteers. Methods Ten healthy volunteers and eight patients with schizophrenia participated in the study. We measured ...

2011-01-01

414

The Adrenal Mass: Correlation of Histopathology with Imaging  

British Library Electronic Table of Contents (United Kingdom)

Background Computed tomography (CT) and magnetic resonance (MR) imaging can help diagnose benign adrenal adenomas, but prior studies rely on nonoperative follow-up as proof of a lesion?s benign nature. We examined adrenalectomy tissues to determine if imaging characteristics correlate with histopathologic findings. Methods We retrieved data for 196 consecutive adrenalectomies in 192 patients from 2000 to 2008. Imaging results were considered to signify benign adrenal adenoma if one or more of the following was present: Hounsfield units 60% or relative contrast washout of >40%, or MR with chemical-shift imaging demonstrating loss of signal intensity on out-of-phase images. Results The sensitivity and specif...

2010-01-01

415

Subclinical interstitial lung involvement in rheumatic diseases. Correlations of high-resolution Computed Tomography patterns with functional and cytologic findings  

International Nuclear Information System (INIS)

The aims of this study were to quantify the severity and extent of subclinical interstitial lung disease as depicted on HRCT and to study the relationship between the patterns of lung disease quantified by HRCT and the functional parameters and bronchoalveolar lavage findings in patients with rheumatic diseases. The results confirm that HRCT is a sensitive tool in detecting interstitial lung disease in patients with rheumatic diseases with no signs and symptoms of pulmonary involvement. The relationship between the different HRCT patterns and bronchoalveolar lavage cell profiles can identify patients at higher risk of developing irreversible lung fibrosis. A long-term, prospective follow-up study is needed to determine whether these patients will develop over pulmonary disease.

1999-01-01

416

Striatal dysfunction in attention deficit and hyperkinetic disorder  

Energy Technology Data Exchange (ETDEWEB)

We have previously reported that periventricular structures are hypoperfused in attention deficit and hyperactivity disorder (ADHD). This study has expanded the number of patients, who were divided into two groups: six patients with pure ADHD, and 13 patients with ADHD in combination with other neurologic symptoms. By using xenon 133 inhalation and emission tomography, the regional cerebral blood flow distribution was determined and compared with a control group. Striatal regions were found to be hypoperfused and, by inference, hypofunctional in both groups. This hypoperfusion was statistically significant in the right striatum in ADHD, and in both striatal regions in ADHD with other neuropsychologic and neurologic symptoms. The primary sensory and sensorimotor cortical regions were highly perfused. Methylphenidate increased flow to striatal and posterior periventricular regions, and tended to decrease flow to primary sensory regions. Low striatal activity, ...

1989-01-01

417

Sonography, Computed Tomography and ERCP in the diagnosis of focal exocrine pancreatic disease  

International Nuclear Information System (INIS)

In spite of the improved imaging techniques currently available, mortality for pancreatic cancer is still high, and pancreatics is often diagnosed only in its advanced stages. The authors investigated the value of different imaging techniques - i.e., US, CT, and ERCP - for an early diagnosis, when a more effective (curative?) treatment can be suggested. Fifty-six cases of pancreatic cancer and 36 cases of chronic pancreatitis were evaluated. The results indicate that ERCP, with the help of statistical methods, is superior to US and CT not only in evaluating early neoplastic or inflammatory lesions, but also for their differential diagnosis. In the letter case, ERCP can sometimes be used as a valid alternative to fine-needle aspiration biopsy.

1991-01-01

418

Solute carrier transporters as targets for drug delivery and pharmacological intervention for chemotherapy  

British Library Electronic Table of Contents (United Kingdom)

Abstract Many solute carrier transporters that interact with anticancer agents and contribute to their pharmacokinetics have been shown to be differentially upregulated in cancer cells as a result of adaptive response to altered nutritional requirements. This review focuses on pathophysiological function of membrane transporters responsible for the influx of physiological substances including oligopeptides, amino acids, and organic cations and anions, and summarizes the recent knowledge regarding mechanisms in their gene expressions. Broad substrate specificity of enhanced oligopeptide H+/peptide cotransporter 1 activity in cancer cells is useful for tumor tissue-specific delivery of chemotherapeutic agents and positron emission tomography diagnostic probes. Amino acid transporters such as...

2011-01-01

419

Reduction of diagnostic expense in space-occupying processes of the pancreas by fine-needle biopsy under computerized tomography (CT)  

International Nuclear Information System (INIS)

Comparative analysis of diagnostic accuracy (dignity determination) in CT-guided fine-needle biopsy (141 patients), CT (141), ultrasonography (89), angiography (50), and cholegraphy (ERCP, 55), was carried out in suspected space-occupying lesions of the pancreas. With accuracy of 86%, sensitivity of 37% and specificity of 92% fine-needle biopsy was superior to imaging procedures. Additional comparison of the results concerning the patients and Roc curves confirm the statements. For reduction of the number of imaging investigations a diagnostic algorithm is proposed, that starts with diagnostic CT and subsequent fine-needle biopsy controlled by CT. This would result in a more adequate use of angiography and ERCP and in the elimination of ultrasonography. (author).

420

Real-time imaging for neutron radiography at KURRI  

International Nuclear Information System (INIS)

For neutron radiography (NR), photographic techniques have been mainly used for many years. To observe a dynamic event and to test many samples, the real-time neutron radiography (i.e. neutron television - NTV) system has been introduced at the E-2 experimental tube of the Kyoto University Research Reactor (KUR). The NTV system has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuel, to investigation of moving objects and to neutron computed tomography (NCT). New approaches using some advanced neutron converters, a high sensitive and resolution TV camera and a high performance image processing system are being undertaken for standard indicators, visualization on air-water two-phase flow, NCT and so on. (author).

1987-07-01

421

Radioiodinated phenoxyacetic acid derivatives as potential brain imaging agents, 2; Structure-biodistribution relationship  

Energy Technology Data Exchange (ETDEWEB)

In developing new brain imaging agents for single photon emission computed tomography (SPECT), we synthesized eleven radioiodinated phenoxyacetic acid derivatives and investigated the relationship between the chemical structure and in vivo characteristics. Biodistribution studies in mice revealed high initial brain uptake for all the compounds. Blood radioactivity level depended markedly upon the chemical stability of the compound. The alpha,alpha-dimethylester derivative, amide derivatives and diamine derivatives, which were stable to hydrolysis, showed low blood activity levels following intravenous administration. Disappearance of the ester and amide compounds from the brain was rapid. However, the diamine derivatives displayed improved retention in the brain. Compounds 3a and 4 possessed the best combination of high brain uptake and sufficient retention to be useful as potential brain imaging radiopharmaceuticals with SPECT devices.

1989-09-01

422

Radioiodinated 1-substituted-4-phenylpiperazines as potential brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

A series of four 125I-labeled 1-substituted-4-phenylpiperazines were prepared and evaluated in rats as potential brain imaging agents. The compounds were labeled using (125I)iodide/chloramine-T or iodine monochloride and isolated in 48-60% radiochemical yields. The tissue distribution studies indicated that a butyrophenone derivative demonstrated the best overall brain-imaging properties. Compared with the compounds having other 1-substituents this agent had a more prolonged retention of activity in the brain and higher brain-to-blood ratios over the 4-h period studied. The in vivo behavior of this agent is comparable to that of radioiodinated N-isopropyl-p-iodoamphetamine, and, because it can be labeled directly via electrophilic methods, it has substantial potential for use in brain imaging with single photon emission computed tomography.

1985-01-01

423

Radiation risk in computerized tomography (CT)  

Energy Technology Data Exchange (ETDEWEB)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on the distance of the exposed region from the ...

1984-01-01

424

Radiation risk in computerized tomography (CT)  

International Nuclear Information System (INIS)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on the distance of the exposed region from the ...

1984-01-01

425

Radiation risk in computerized tomography (CT)  

International Nuclear Information System (INIS)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on the distance of the exposed region from the ...

426

Preoperative image diagnosis of hypertrophied parathyroid glands in patients with renal osteodystrophy  

International Nuclear Information System (INIS)

Computed tomography (CT) of the neck and mediastinum was performed in 16 patients with renal osteodystrophy. Thirty out of 34 excised parathyroid glands weighing more than 500mg were diagnosed preoperatively (88.2%). Scintigraphy of the neck with _2_0_1TlCl and sup(99m)TcOsub(4-) was also performed in 15 patients. The introduction of subtraction method with a mini-computor in the scintigraphy has remarkably improved the visualization rate of parathyroid glands. Ultrasonic echography (US) of the neck which is able to obtain not only transverse butalso longitudinal imaging was done in 7 patients. It has about same detection rate of the glands with CT. The visualization of enlarged parathyroid glands is valuable not only for localization but also for undeniable evidence of hyperparathyroidism. Also, repeated follow-up examination can determine the effectiveness of conservative treatment. (author).

427

Pore-structure models of hydraulic conductivity for permeable pavement  

British Library Electronic Table of Contents (United Kingdom)

SummaryPermeable pavement functions as a porous infrastructure interface allowing the infiltration and evaporation of rainfall-runoff while functioning as a relatively smooth load-bearing surface for vehicular transport. Hydraulic conductivity (k) of permeable pavement is an important hydraulic property and is a function of the pore structure. This study examines k for a cementitious permeable pavement (CPP) through a series of pore-structure models. Measurements utilized include hydraulic head as well as total porosity, (t), effective porosity (e), tortuosity (Le/L) and pore size distribution (PSD) indices generated through X-ray tomography (XRT). XRT results indicate that the permeable pavement pore matrix is hetero-disperse, with high tortuosity and t!=e. Power law models of k-t and k-e...

2011-01-01

428

Photoreceptor Inner and Outer Segment Defects in Myopic Foveoschisis  

British Library Electronic Table of Contents (United Kingdom)

PurposeTo evaluate pathologic features of the photoreceptors in myopic foveoschisis with the Fourier-domain optical coherence tomography (FD-OCT).DesignObservational case series.MethodsSeventeen eyes of 15 patients with myopic foveoschisis (foveal detachment type, six eyes; foveoschisis type, 11 eyes) were included. We observed the photoreceptor inner and outer segments (IS/OS) and evaluated the morphologic status using FD-OCT. Fundus photographs and time-domain OCT (TD-OCT) images also were obtained.ResultsIS/OS defects, which are uncommon in retinal detachments in eyes with myopia, were seen clearly in five eyes (three eyes [50%] with the foveal detachment type; two eyes [18%] with the foveal schisis type). Fundus photographs showed myopic chorioretinal atrophy in eight study eyes (47%),...

2008-01-01

429

Noninvasive prediction of vertebral body compressive strength using nonlinear finite element method and an image based technique  

British Library Electronic Table of Contents (United Kingdom)

Noninvasive prediction of vertebral body strength under compressive loading condition is a valuable tool for the assessment of clinical fractures. This paper presents an effective specimen-specific approach for noninvasive prediction of human vertebral strength using a nonlinear finite element (FE) model and an image based parameter based on the quantitative computed tomography (QCT). Nine thoracolumbar vertebrae excised from three cadavers with an average age of 42 years old were used as the samples. The samples were scanned using the QCT. Then, a segmentation technique was performed on each QCT sectional image. The segmented images were then converted into three-dimensional FE models for linear and nonlinear analyses. A new material model was implemented in our nonlinear model being more...

2010-01-01

430

Nondestructive characterization of low-level transuranic waste  

Energy Technology Data Exchange (ETDEWEB)

The use of nondestructive evaluation (NDE) methods is proposed for characterization of transuranic (TRU) waste stored at the Radioactive Waste Management Complex. These NDE methods include real-time x-ray radiography, real-time neutron radiography, x-ray and neutron computed tomography, thermal imaging, container weighing, visual examination, and acoustic measurements. An integrated NDE system is proposed for characterization and certification of TRU waste destined for eventual shipment to the Waste Isolation Pilot Plant in New Mexico. Methods for automating both the classification waste and control of a complete nondestructive evaluation/nondestructive assay system are presented. Feasibility testing of the different NDE methods, including real-time x-ray radiography, and development of automated waste classification techniques are covered as part of a five year effort designed to yield a production waste characterization system.

1981-10-01

431

Multi-Mode Lamb Wave Arrival Time Extraction for Improved Tomographic Reconstruction  

International Nuclear Information System (INIS)

An ultrasonic signal processing technique is applied to multi-mode arrival time estimation from Lamb waveforms. The basic tool is a simplified time-scale projection called a dynamic wavelet fingerprint (DWFP) which enables direct observation of the variation of features of interest in non-stationary ultrasonic signals. The DWFP technique was used to automatically detect and evaluate each candidate through-transmitted Lamb mode. The area of the dynamic wavelet fingerprint was then used as a feature to distinguish false modes caused by noise and other interference from the true modes of interest. The set of estimated arrival times were then used as inputs for tomographic reconstruction. The Lamb wave tomography images generated with these estimated arrival times were able to indicate different defects in aluminum plates.

2005-04-09

432

Magnetic resonance imaging in joint diseases  

International Nuclear Information System (INIS)

Magnetic resonance imaging has proven an invaluable method in the diagnosis of joint diseases associated with osteonecrotic, inflammatory, traumatic and degenerative processes. At the clinical level, it has an important role in decisions about the method of treatment and evaluations of the therapeutic success. When the merits of MRT are balanced against those of conventional radiography including tomography and CT, which both ensure better spatial resolution in the visualisation of cortical and spongy bone structures, it becomes quite evident that MRT must not be regarded as an alternative method of imaging but as one that can be used additionally to obtain the most information for the diagnosis of arthropathy. The question as to whether new pulse sequences (snap shots) or invasive techniques like intra-articular injection of paramagnetic substances (MR arthrography) are likely to become routine procedures in the detection of joint diseases using MRT remains to be ...

433

Long-term survival following radical surgery after chemotherapy for esophagogastric adenocarcinoma with extensive lymph node metastases: Report of a case  

British Library Electronic Table of Contents (United Kingdom)

A 46-year-old man was referred to us after he presented to his local physician complaining of difficulty eating. Upper gastrointestinal endoscopy revealed a tumor at the esophagogastric junction (EGJ), and moderately differentiated adenocarcinoma was diagnosed from the biopsy findings. Computed tomography (CT) showed apparent enlargement of the pretracheal lymph nodes, the lymph nodes around the bilateral recurrent laryngeal nerves, and the lower thoracic paraesophageal lymph nodes, confirming metastasis. Since the disease was far advanced esophagogastric cancer with marked lymph node metastases throughout the mediastinum, curative resection would have been unlikely. Thus, he was commenced on systemic chemotherapy with cisplatin (90 mg/body, day 8) + S-1 (120 mg/body/day, given for 3 weeks...

2011-01-01

434

Laparoscopic Transduodenal Ampullectomy for Benign Ampullary Tumors  

British Library Electronic Table of Contents (United Kingdom)

Abstract Introduction: Transduodenal ampullectomy (TDA) can be performed for benign and premalignant tumors of the ampulla of Vater (AOV) as an alternative to pancreaticoduodenectomy. However, the laparoscopic approach has rarely been attempted. In this report 2 cases of benign ampullary tumor that were treated by totally laparoscopic TDA. Patients and Methods: Case 1 was of a 75-year-old female who was admitted with left knee pain and underwent arthroscopic debridement. On postoperative day 6, she showed elevated levels of alkaline phosphatase, aspirate aminotransferase, alanine transaminase, and gamma-glutamyl transpeptidase, without any other laboratory test abnormality. She had no complaint of abdominal pain, and physical examinations were unremarkable. Computed tomography (CT), magnet...

2010-01-01

435

Interventional MR imaging: Clinical results obtained with a 1.5 Tesla system; Interventionelle MR-Tomographie: Klinische Erfahrungen mit einem 1,5 Tesla System  

Energy Technology Data Exchange (ETDEWEB)

The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.) [Deutsch] Es wurde die klinische Durchfuehrbarkeit interventioneller Techniken an einem kombinierten Durchleuchtungs- und MR-Arbeitsplatz untersucht. Dieses Hybridsystem erwies sich bei einer Vielzahl interventioneller Eingriffe als vorteilhaft. Der 1,5 Tesla-Magnet ist offenen MR-Systemen hinsichtlich Bildqualitaet und Messzeit ueberlegen. (orig.)

1997-05-01

436

Imaging pharmacodynamics in oncology. The potential significance of 'flares'  

International Nuclear Information System (INIS)

The clinical use of "1"8F-fluorodeoxyglucose (FDG) positron emission tomography in monitoring anticancer treatment is expanding. At the same time a number of radiotracers aiming to image different aspects of tumour biology such as proliferation and apoptosis are being developed. However, the factors determining changes of radiotracer uptake parameters in response to treatment are not well understood. In many cases, cellularity may be the primary determinant of changes of FDG uptake and may confound the interpretation of metabolic changes. Early imaging assessments have in some cases showed transient increases of uptake parameters, commonly termed 'flares', which are likely to be unaffected by cellularity and directly reflect pharmacodynamics at a cellular level. In this review a number of settings where molecular imaging 'flares' have been described are discussed. Such changes may often be clinically informative and warrant careful study as potential predictive ...

2010-04-01

437

Image-guided percutaneous cryotherapy for the management of gynecologic cancer metastases  

British Library Electronic Table of Contents (United Kingdom)

Objective To report the clinical response to image-guided percutaneous cryotherapy (IPC) for the palliative management of localized metastases in patients with gynecologic malignancies. Methods Institutional review board approval and patient consent were obtained. Gynecologic oncology patients were identified from our institution's cryotherapy database from August 2003 to August 2007. Cryotherapy was performed with 2.4?mm diameter probes (Endocare, Irvine, CA) with ultrasound or computerized tomography (CT) guidance under conscious sedation and local anesthesia. Follow-up was conducted by imaging studies and clinical encounters, using Response Evaluation Criteria in Solid Tumors (RECIST criteria). Results Twenty-eight ablation sessions were performed for 41 metastatic foci in 15 patients w...

2008-01-01

438

Image diagnosis of parathyroid glands in chronic renal failure  

Energy Technology Data Exchange (ETDEWEB)

Twenty-two out of 31 patients with chronic renal failure and secondary hyperparathyroidism who underwent parathyroidectomy before operation underwent non-invasive image diagnosis of parathyroid glands by computed tomography (CT), scintigraphy with /sup 201/TlCl and /sup 99m/TcO/sup 4 +/, and/or ultrasonography. CT visualized 39 of 45 parathyroid glands (86.7%), weighing more than 500 mg. Scintigraphy with a subtraction method using a computer performed the diagnosis in 19 of 27 glands (70.4%). Ultrasonography detected 21 of 27 glands (77.8%). Image diagnosis was also useful in the postoperative follow-up study. The non-invasive image diagnosis of parathyroid glands in patients with chronic renal failure is thus valuable for 1) definite diagnosis of secondary hyperparathyroidism, 2) localization, and 3) diagnosis for effectiveness of conservative treatment.

1983-07-01

439

Fundamental concepts of digital image processing  

Science.gov (United States)

The field of a digital-image processing has experienced dramatic growth and increasingly widespread applicability in recent years. Fortunately, advances in computer technology have kept pace with the rapid growth in volume of image data in these and other applications. Digital image processing has become economical in many fields of research and in industrial and military applications. While each application has requirements unique from the others, all are concerned with faster, cheaper, more accurate, and more extensive computation. The trend is toward real-time and interactive operations, where the user of the system obtains preliminary results within a short enough time that the next decision can be made by the human processor without loss of concentration on the task at hand. An example of this is the obtaining of two-dimensional (2-D) computer-aided tomography (CAT) images. A medical decision might be made while the patient is still under observation rather ...

1983-03-01

440

Formulation and practice of standards for radiation protection of #gamma#-ray industrial computed tomography  

International Nuclear Information System (INIS)

There are many differences between industrial CT and industrial radiography, such as imaging principle, inspection time, radiation dose and the requirements for operators etc. The national standards for radiation protection of industrial detection are not applicable to the requirements of protection and safety for #gamma#-ray industrial CT to some extent now. In order to standardize the production and use for #gamma#-ray industrial CT, protect the safety of operators and the public, and to promote the popularization and application of #gamma#-ray industrial CT, it is significant to establish the national standards for radiation protection of #gamma#-ray industrial CT as soon as possible. The purpose of this paper is to introduce the contents of this standard, and specify some important terms. Then there is a brief discussion on the existing problems during establishing such standards. At last, the paper summarize the practice of the standards passed over the past one year, which ...

2009-03-01

441

Feeding of the megamouth shark (Pisces: Lamniformes: Megachasmidae) predicted by its hyoid arch: A biomechanical approach  

British Library Electronic Table of Contents (United Kingdom)

Abstract Studies of the megamouth shark, one of three planktivorous sharks, can provide information about their evolutionary history. Megamouth shark feeding has never been observed in life animals, but two alternative hypotheses on biomechanics suggest either feeding, i.e., ram feeding or suction feeding. In this study, the second moment of area of the ceratohyal cartilages, which is an indicator of the flexural stiffness of the cartilages, is calculated for 21 species of ram- and suction-feeding sharks using computed tomography. The results indicate that suction-feeding sharks have ceratohyal cartilages with a larger second moment of area than ram-feeding sharks. The result also indicates that the ram-suction index, which is an indicator of relative contribution of ram and suction behavi...

2011-01-01

442

Extrinsic allergic alveolitis induced by the yeast Debaryomyces hansenii.  

Science.gov (United States)

A 65-yr-old female developed cough, fever and dyspnoea following repeated exposure to a home ultrasonic humidifier. High-resolution computed tomography showed ground-glass opacity in both lung fields. Arterial blood gas analysis gave an oxygen tension of 8.38 kPa (63 Torr). Pulmonary function testing revealed restrictive ventilatory impairment with a reduction in the diffusing capacity. The diagnosis of extrinsic allergic alveolitis (EAA) was confirmed by radiographic findings, pathological evidence of alveolitis and reproductive development by a provocation test to the humidifier water. The yeast Debaryomyces Hansenii was the only microorganism cultured from the water of the humidifier. The double diffusion precipitating test and lymphocyte proliferative response was positive for an extract of D. Hansenii, providing evidence to incriminate this fungus. This is the first described case of EAA caused by D. Hansenii. PMID:12449192

2002-11-01

443

Electromagnetic fields - introduction to relevant issues  

International Nuclear Information System (INIS)

This introductory paper surveys potential sources of electric magnetic, and electro-magnetic fields. Various cases are discussed to exemplify the total frequency range: nuclear magnetic resonance tomography, high-voltage transmission lines, transformer stations, effect lighting balls, military transmitters, transmitter towers of the Postal Services and other operators, mobile radiotelephone equipment, large broadcasting transmitters, radar radiation, high-frequency heat therapy. There is evidence suggesting that electric, magnetic and electro-magnetic fields may possibly represent a certain nuisance or health hazard even at field strength occuring in equipment used for every-day-life purposes, with an emphasis on their possible actions and effects in children and adolescents. The author discusses, in conclusion, the aerial equipment ordinance issued by Lower Saxony. (Uhe).

1993-06-01

444

Early-stage focal nodular hyperplasia: US/CT/MR features correlated with histology  

Energy Technology Data Exchange (ETDEWEB)

Two cases of focal nodular hyperplasia (FNH), in which ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MR) studies detected an atypical hemorrhagic pattern associated with an intrahepatic arterio venous malformation (AVM) around the growths, are presented. In both cases, histology demonstrated a very early regenerative stage and necrotic-hemorrhagic areas within the lesions. In these cases, the analysis of radiological findings, surgical specimens and histology seemed to confirm the pathogenetic hypothesis suggested by Wanless: in normal liver parenchyma, a ``blood steal`` phenomenon due to congenital or acquired intrahepatic AVM could cause ischemic damage, appearing as a hemorrhagic necrotic area, the extent of which depends on the degree of residual portal supply. (orig.)

1994-02-01

445

Copper-64 Radiopharmaceuticals for PET Imaging of Cancer: Advances in Preclinical and Clinical Research  

British Library Electronic Table of Contents (United Kingdom)

Summation Copper-64 (T1/2?=?12.7 hours; ?+, 0.653?MeV [17.8 %]; ??, 0.579?MeV [38.4 %]) has decay characteristics that allow for positron emission tomography (PET) imaging and targeted radiotherapy of cancer. The well-established coordination chemistry of copper allows for its reaction with a wide variety of chelator systems that can potentially be linked to peptides and other biologically relevant small molecules, antibodies, proteins, and nanoparticles. The 12.7-hours half-life of 64Cu provides the flexibility to image both smaller molecules and larger, slower clearing proteins and nanoparticles. In a practical sense, the radionuclide or the 64Cu-radiopharmaceuticals can be easily shipped for PET imaging studies at sites remote to the production facility. Due to the versatility of 64Cu, ...

2009-01-01

446

Contrast material extravasation following upper abdominal trauma. Detection with helical Computerized Tomography  

International Nuclear Information System (INIS)

Active contrast material extravasation can be recognized with conventional CT scanners, though it has been considered a rare finding. Helical CT seems to increase the detection rate and especially to boost the radiologist's confidence in this diagnosis. Though active bleeding is defined in severely-injured subjects requiring urgent intervention and may be associated with findings of hypovolaemic shock, it should not be considered itself as a negative prognostic factor. Contrast extravasation is due to ongoing hemorrhage and its detection is critical for urged treatment. Accurate anatomical location permits to choose surgical management or transcatheter embolization and thus decreases time consumption for precis e bleeding site identification.

1999-03-01

447

Computed tomography of the acetabular fractures  

Energy Technology Data Exchange (ETDEWEB)

In a retrospective study of 21 patients, in whom the acetabular fractures were suspected on initial radiographs, we compared and analysed the computed tomographic findings and plain radiographic findings. The results were as follow: 1. In patients with multiple trauma, no further change in position was required during CT examinations. 2. CT showed intraarticular loose bodies, which were invisible on plain radiographs. 3. CT was useful in detecting the fractures of acetabular rims, medial wall of acetabulum, and femoral head. 4. CT permitted better evaluation of shape, extent, and degree of separation of fracture fragments. 5. CT was helpful in detecting the associated fractures and soft tissue injuries. 6. CT also demonstrated the adequacy of reduction, the position of metallic fixation devices, and the presence or absence of remaining intraarticular osseous fragments after surgery.

1986-04-15

448

Computed tomography of middle ear cholesteatomas without tympanic membrane perforation  

International Nuclear Information System (INIS)

The growth of a middle ear cholesteatoma behind a normal tympanic membrane is a rate though possible event. In such cases, CT may provide useful information for diagnosis. The results are presented of a CT study carried out on 14 patients affected with unilateral conductive hearing loss and with normal tympanic membrane. CT allowed the diagnosis of meddle ear cholesteatoma to be made in all cases. All patients were treated with surgery: 8 of them underwent tympanoplasty and 6 explorative tympanotomy. While the diagnosis of cholesteatoma was confirmed in 13 patients, in 1 case tympanosclerosis was diagnosed. CT diagnosis of middle ear cholesteatoma is based on the demonstration of a low-density soft-tissue mass, in association with bone erosion or ossicular dislocation. The author emphasizes the difficulty of a CT diagnosis of cholesteatoma in the patients with middle ear soft-tissue masses in the absence of bone alterations.

1991-01-01

449

Computational mouse atlases and their application to automatic assessment of craniofacial dysmorphology caused by the Crouzon mutation Fgfr2C342Y  

British Library Electronic Table of Contents (United Kingdom)

Abstract Crouzon syndrome is characterized by premature fusion of sutures and synchondroses. Recently, the first mouse model of the syndrome was generated, having the mutation Cys342Tyr in Fgfr2c, equivalent to the most common human Crouzon/Pfeiffer syndrome mutation. In this study, a set of micro-computed tomography (CT) scannings of the skulls of wild-type mice and Crouzon mice were analysed with respect to the dysmorphology caused by Crouzon syndrome. A computational craniofacial atlas was built automatically from the set of wild-type mouse micro-CT volumes using (1) affine and (2) non-rigid image registration. Subsequently, the atlas was deformed to match each subject from the two groups of mice. The accuracy of these registrations was measured by a comparison of manually placed landma...

2007-01-01

450

Clinical evaluation of Fuji computed radiography (FCR) by physicians including non-radiologist  

Energy Technology Data Exchange (ETDEWEB)

In Niigata University Hospital, most of conventional radiography were changed to Fuji computed Radiography (FCR) from July 1988. To evaluate its clinical utility, questionnaires relating to FCR image were distributed to all physicians including non-radiologists in the hospital after three months. The ratio of the physicians evaluated FCR image to be better than conventional image was 75% in chest radiography, 64% in abdominal radiography. FCR tomography of bone, joint, cranium and chest was also evaluated to be better than conventional by most of the physicians. Reduced size of the film and difficulty in detecting interstitial shadows of the lung were mentioned to be the fault of FCR. (author).

1990-04-01

451

Clinical evaluation of Fuji computed radiography (FCR) by physicians including non-radiologist  

International Nuclear Information System (INIS)

In Niigata University Hospital, most of conventional radiography were changed to Fuji computed Radiography (FCR) from July 1988. To evaluate its clinical utility, questionnaires relating to FCR image were distributed to all physicians including non-radiologists in the hospital after three months. The ratio of the physicians evaluated FCR image to be better than conventional image was 75% in chest radiography, 64% in abdominal radiography. FCR tomography of bone, joint, cranium and chest was also evaluated to be better than conventional by most of the physicians. Reduced size of the film and difficulty in detecting interstitial shadows of the lung were mentioned to be the fault of FCR. (author).

1988-07-01

452

Challenges in presenting high dimensional data to aid in triage in the DARPA virtual soldier project.  

Science.gov (United States)

One of the goals of the DARPA Virtual Soldier Project is to aid the field medic in the triage of a casualty. In Phase I, we are currently collecting 12 baseline experimental physiological variables and a cardiac gated Computed Tomography (CT) imagery for use in an prototyping a futuristic electronic medical record, the "Holomer". We are using physiological models and Kalman filtering to aid in diagnosis and predict outcomes in relation to cardiac injury. The physiological modeling introduces another few hundred variables. Reducing the complexity of the above into easy-to-read text to aid in the triage by the field medic is the challenge with multiple display solutions. A description of the possible techniques follows. PMID:15718701

2005-01-01

453

Calcified metastases of the kidney. Etiology, pathogenesis, CT findings and diagnostic problems; Metastasi renali calcificate: eziologia, patogenesi, aspetti con tomografia computerizzata e diagnostica differenziale  

Energy Technology Data Exchange (ETDEWEB)

Aim of the work was to describe computerised tomography (CT) findings of calcified renal metastases focusing on differential diagnosis problems. Abdominal CT scans of 8000 patients with tumor, performed from 1984 to 1998, have been retrospectively reviewed. [Italian] Scopo del lavoro e' quello di descrivere gli aspetti con tomografia computerizzata delle metastasi renali calcificate enfatizzando le problematiche diagnostico differenziali. Sono state valutate retrospettivamente le indagini TC addominali di 8000 pazienti affetti da tumore nel periodo 1984-1998, analizzando le lesioni calcificate riscontrate.

2000-03-01

454

CT colonoscopy with volume rendering. Results and comparison with endoscopy and surgery; Cononscopia con tomografia computerizzata con ricostruzioni di volume: risultati e confronto con endoscopia  

Energy Technology Data Exchange (ETDEWEB)

The paper reports the results of a preliminary experience with volume rendering technique of virtual computerized tomography colonoscopy and compares it with endoscopy and surgery showing its capability in detecting colon and rectal cancers. [Italian] Scopo del lavoro e' riportare l'esperienza personale preliminare nell'uso della colonscopia TC virtuale confrontando i risultati con quelli dell'endoscopia e dei riscontri operatori, dimostrandone l'efficacia nella diagnosi delle malattie tumorali del colon-retto.

1999-09-01

455

CANDU 6 fuel behaviour in power ramp conditions  

International Nuclear Information System (INIS)

The facilities in the Institute for Nuclear Research at Pitesti allow the testing, handling and examination of nuclear fuel and irradiated materials. The most important facilities are the TRIGA Steady State Research and Material Test Reactor and the Post-Irradiation Examination Laboratory (PIEL). The purpose of this work is to determine by post-irradiation examination, the behavior of CANDU fuel, irradiated in 14 MW TRIGA reactor. The fuel was irradiated in power ramp conditions. The results of post-irradiation examination are: - Visual inspection and photography of the outer appearance of sheath; - Profilometry (diameter, bending, ovality) and length measuring; - Determination of axial and radial distribution of the fusion products activity by gamma scanning and tomography; - Microstructural characterization by metallographic and ceramographic analyzes; - Mechanical properties determination. The data obtained from the post-irradiation examination are used to ...

2009-10-12

456

Brain tumor in childhood. Hjernesvulst hos barn  

Energy Technology Data Exchange (ETDEWEB)

Brain tumor was diagnosed by computer tomography or magnetic resonance imaging in 100 children aged 0 to 19 years. They consecutively underwent primary surgical treatment during the years 1984 to 1988. Non-neoplastic lesions and operations for residual tumors are not included. 54 tumors were localized supratentorially. 72% of these were benign og low grade malignancies. 46 tumors had an infratentorial localication. 59% of these were high grade malignancies. Children tolerate major-neurosurgical procedures better than adults and restitution is usually favourable. 42 children with high grade malignancies underwent postoperative radiotherpy. Per- and postoperative mortality in this series was 1%. 80 children are alive. 62 of these are in excellent condition after a median observation time of 40 months. 10 refs.

1990-05-01

457

Evaluate Potential Means of Rebuilding Sturgeon Populations in the Snake River between Lower Granite and Hells Canyon Dams, 2001 Annual Report.  

Energy Technology Data Exchange (ETDEWEB)

The specific research goal of this project is to identify means to restore and rebuild the Snake River white sturgeon (Acipenser transmontanus) population to support a sustainable annual subsistence harvest equivalent to 5 kg/ha/yr (CBFWA 1997). Based on data collected, a white sturgeon adaptive management plan will be developed. This 2001 annual report covers the fifth year of sampling of this multi-year study. In 2001 white sturgeon were captured, marked, and population data were collected in the Snake and Salmon rivers. The Snake River was sampled between Lower Granite Dam (rkm 174) and the mouth of the Salmon River (rkm 303), and the Salmon River was sampled from its mouth upstream to Hammer Creek (rkm 84). A total of 45,907 hours of setline effort and 186 hours of hook-and-line effort was employed in 2001. A total of 390 white sturgeon were captured and tagged in the Snake River and 12 in the Salmon River. Since 1997, 36.1 percent of the tagged white sturgeon have been recaptured. ...

2003-03-01

458

Truck tactics: dispatch from Vancouver  

Energy Technology Data Exchange (ETDEWEB)

Any mine that uses haultrucks has a dispatching system of some sort, even if it is only a very basic and simple arrangement. The larger, more complex operations have found that, if properly applied, automated computerised dispatching improves the productivity of the equipment as well as improving overall control and reporting. However, not every mine can justify going this far; in these cases a computerised monitoring and reporting system with manual dispatching can still give considerable benefits. Wenco International Mining Systems of Vancouver supplies its computerised system to three different specification levels to suit most open pit mining operations. The article describes the 3 PMCSs (Production Monitoring and Control System) available: PMCS 1000, for monitoring and reporting only; PMCS 2000, for dispatching to maximise production; and PMCS 3000, for dispatching with optimised product quality and production. The major components of the PMCS are: mobile data terminals fitted to ...

1991-11-01

459

Spontaneous emission spectra and simulating multiple spontaneous generation coherence in a five-level atomic medium  

Science.gov (United States)

We investigate the features of the spontaneous emission spectra in a coherently driven cold five-level atomic system by means of a radio frequency (rf) or microwave field driving a hyperfine transition within the ground state. It is shown that a few interesting phenomena such as spectral-line narrowing, spectral-line enhancement, spectral-line suppression, and spontaneous emission quenching can be realized by modulating the frequency and intensity of the rf-driving field in our system. In the dressed-state picture of the coupling and rf-driving fields, we find that this coherently driven atomic system has three close-lying levels so that multiple spontaneously generated coherence (SGC) arises. Our considered atomic model can be found in real atoms, such as rubidium or sodium, so a corresponding experiment can be done to observe the expected phenomena related to SGC reported by Fountoulakis et al. [Phys. Rev. A 73, 033811 (2006)], since no rigorous conditions are ...

2006-09-15

460

Spectroscopic studies on the interaction of the antibiotic lasalocid A (x-537a) with technetium (V) ions in methanol  

International Nuclear Information System (INIS)

In the present study, the authors examine the interactions of pentavalent technetium ions (TcO/sup 3+/) with the basic form of the lasalocid A in pure methanol solvent and in methanol-water mixtures. There are a number of reasons for such a study. First, the interactions of technetium ions with biologically important compounds are of considerable importance owing to the widespread use of /sup 99m/Tc in diagnostic radio-imaging. Second, lasalocid A is known to transport metal ions across phospholipid bilayer membranes and between the aqueous cores of phospholipid inverse micelles. Third, lasalocid A is known to bind and solubilize metal ions in bulk organic liquid phases. Fourth, the conformation adopted by lasalocid A on interaction with TcO/sup 3+/ appears to be different than those found in most other cases and circumstances. Fifth, it may also be possible to use the competition of TcO/sup 3+/ with other, physiologically relevant cations (Na/sup +/, K/sup +/, ...

461

Salivary cortisol assessment in the evaluation of hypothalamic-pituitary-adrenal function  

International Nuclear Information System (INIS)

A simple, short and sensitive direct radio-immunoassay technique for the determination of salivary cortisol concentration was employed to assess saliva as a medium for evaluating cortisol response during endocrine testing in 9 controls and 40 patients. Results in controls suggested that an adequate salivary cortisol response to insulin hypoglycaemia was an increase of 150% above the basal value with a minimum peak of 15 nmol/l. Thirty-three patients were classified as being either good or poor responders to insulin hypoglycaemia on the basis of criteria for plasma cortisol levels. When the defined salivary cortisol response was used for assessment, all 33 patients were correctly categorized into the same response groups. The salivary cortisol response to intramuscular tetracosactin in 3 patients and an intravenous dexamethasone infusion in 4 patients confirmed the value of saliva as an assay medium. These studies show that the salivary cortisol response parallels ...

1984-05-01

462

Role of accelerator mass spectrometry in biological dosimetry  

International Nuclear Information System (INIS)

Understanding risks from exposures to carcinogens and other chemicals depends upon measurement of their dose to target tissues and their reactivity with critical macromolecules. The authors have used AMS detection of radio-isotopes to assess doses and reactivities at low, environmentally relevant doses. Several biomedical investigations show the effectiveness of quantification of biologically important events at extremely high sensitivity with AMS. Specifically, they have measured the addition of environmental carcinogens such as 2-amino-3,8-dimethylimidazo[4,5-f]-quinoaxaline (MelQx), a chemical found in cooked food, to DNA at concentrations relevant to human exposure. Other low level detection problems in biology, such as immunoassay assessment of small environmental chemicals, is being developed with attomole sensitivity. AMS also aids the assessment of genotoxic risks from chemicals by quantifying the binding of labeled chemicals to DNA. The very toxic and ...

1992-04-05

463

Radiant{trademark} Liquid Radioisotope Intravascular Radiation Therapy System  

Energy Technology Data Exchange (ETDEWEB)

RADIANT{trademark} is manufactured by United States Surgical Corporation, Vascular Therapies Division, (formerly Progressive Angioplasty Systems). The system comprises a liquid {beta}-radiation source, a shielded isolation/transfer device (ISAT), modified over-the-wire or rapid exchange delivery balloons, and accessory kits. The liquid {beta}-source is Rhenium-188 in the form of sodium perrhenate (NaReO{sub 4}), Rhenium-188 is primarily a {beta}-emitter with a physical half-life of 17.0 hours. The maximum energy of the {beta}-particles is 2.1 MeV. The source is produced daily in the nuclear pharmacy hot lab by eluting a Tungsten-188/Rhenium-188 generator manufactured by Oak Ridge National Laboratory (ORNL). Using anion exchange columns and Millipore filters the effluent is concentrated to approximately 100 mCi/ml, calibrated, and loaded into the (ISAT) which is subsequently transported to the cardiac catheterization laboratory. The delivery catheters are modified Champion{trademark} ...

1998-01-16

464

QoS-Aware Joint Policies in Cognitive Radio Networks  

CERN Document Server

One of the most challenging problems in Opportunistic Spectrum Access (OSA) is to design channel sensing-based protocol in multi secondary users (SUs) network. Quality of Service (QoS) requirements for SUs have significant implications on this protocol design. In this paper, we propose a new method to find joint policies for SUs which not only guarantees QoS requirements but also maximizes network throughput. We use Decentralized Partially Observable Markov Decision Process (Dec-POMDP) to formulate interactions between SUs. Meanwhile, a tractable approach for Dec-POMDP is utilized to extract sub-optimum joint policies for large horizons. Among these policies, the joint policy which guarantees QoS requirements is selected as the joint sensing strategy for SUs. To show the efficiency of the proposed method, we consider two SUs trying to access two-channel primary users (PUs) network modeled by discrete Markov chains. Simulations demonstrate three interesting findings: 1- Optimum joint ...

2010-01-01

465

Probing the Origins of the CIV and Fe Kalpha Baldwin Effect  

CERN Document Server

We use UV/optical and X-ray observations of 272 radio-quiet Type 1 AGNs and quasars to investigate the CIV Baldwin Effect (BEff). The UV/optical spectra are drawn from the Hubble Space Telescope, International Ultraviolet Explorer and Sloan Digital Sky Survey archives. The X-ray spectra are from the Chandra and XMM-Newton archives. We apply correlation and partial-correlation analyses to the equivalent widths, continuum monochromatic luminosities, and alpha_ox, which characterizes the relative X-ray to UV brightness. The equivalent width of the CIV 1549 emission line is correlated with both alpha_ox and luminosity. We find that by regressing l_UV with EW(CIV) and alpha_ox, we can obtain tighter correlations than by regressing l_UV with only EW(CIV). Both correlation and regression analyses imply that l_UV is not the only factor controlling the changes of EW(CIV); alpha_ox (or, equivalently, the soft X-ray emission) plays a fundamental role in the formation and ...

2009-01-01

466

Pre-transitional disk nature of the AB Aur disk  

CERN Document Server

The disk around AB Aur was imaged and resolved at 24.6\\,$\\mu$m using the Cooled Mid-Infrared Camera and Spectrometer on the 8.2m Subaru Telescope. The gaussian full-width at half-maximum of the source size is estimated to be 90 $\\pm$ 6 AU, indicating that the disk extends further out at 24.6\\,$\\mu$m than at shorter wavelengths. In order to interpret the extended 24.6\\,$\\mu$m image, we consider a disk with a reduced surface density within a boundary radius $R_c$, which is motivated by radio observations that suggest a reduced inner region within about 100 AU from the star. Introducing the surface density reduction factor $f_c$ for the inner disk, we determine that the best match with the observed radial intensity profile at 24.6\\,$\\mu$m is achieved with $R_c$=88 AU and $f_c$=0.01. We suggest that the extended emission at 24.6\\,$\\mu$m is due to the enhanced emission from a wall-like structure at the boundary radius (the inner edge of the outer disk), which ...

2010-01-01

467

Performance enhancement of a compact radio frequency ion source by the injection of supplemental electrons  

Energy Technology Data Exchange (ETDEWEB)

A versatile, high brightness, volume type, low power RF source, capable of producing positive ion beams with intensities as high as 1 mA from gaseous feed materials and microamperes of negative ion beams has been characterized. The source can also be operated as a plasma sputter negative ion source to generate up to 1 mA of a selected species. The performance of the source in the positive and negative volume modes of operation can be greatly enhanced by addition of a removable, water cooled filament assembly in place of the negative sputter probe. For examine, the material utilization efficiencies of gaseous feed species can be more than doubled, total current intensities increased up to 40%, molecular dissociation fractions increased by 20% and minimum operating pressures reduced by a factor of four when operated in the volume mode. These added electrons also favorably effect, as a consequence of lower pressures, the emittance apparently through a reduction of scattering in the beam ...

1995-07-01

468

Novel InN growth method under In-rich condition on GaN/Al2O3(0001) templates  

International Nuclear Information System (INIS)

A novel technique is proposed for the growth of an InN film on a GaN/Al2O3(0001) template by radio-frequency plasma-excited molecular beam epitaxy (RF-MBE). The method involves 1) InN growth under an In-rich condition and 2) additional nitrogen radical irradiation after the InN growth under an In-rich condition. Excess In that appeared on the InN surface in the InN growth under an In-rich condition is transformed to InN by the additional nitrogen radical irradiation. The effective V/III ratio is easily controlled by monitoring the intensity in a reflection high-energy electron diffraction (RHEED) pattern. The growth of the InN film by repeating the InN growth under an In-rich condition and the additional nitrogen radical irradiation is also demonstrated. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

2009-06-01

469

Non-hematological tumors of head and neck region in the pediatric age group in a tertiary care cancer center  

British Library Electronic Table of Contents (United Kingdom)

Purpose To analyze the clinical profile, management and outcome of non-hematological tumors in head and neck region in children less than 18?years of age. Patients and methods Medical records of patients (0?18?years) presenting with non-hematological tumors of head and neck region from 2000 to 2010 were reviewed. Result Out of the 78 patients identified, 50 were males with median age of 14?years (3?months to 18?years). Histologically, 58 out of the 78 patients had malignant tumors and 20 were metastatic at presentation. Common site of tumor origin was noted as thyroid (23/78), salivary glands (21/78) and nasopharynx (13/78). Out of 78 patients, 44 patients were treated by surgery, 26 patients received radiation and 13 patients received chemotherapy, while 9 patients received radio-iodine (...

2011-01-01

470

Mid-latitude scintillation model. Technical report, 1 November 1985-31 October 1986  

Energy Technology Data Exchange (ETDEWEB)

Radiowave scintillation in the presence of ionospheric disturbances has the potential to disrupt numerous transionospheric radio and radar systems. This report describes development of a model characterizing the plasma density irregularities that produce scintillation in the naturally disturbed mid-latitude F layer. The model will be incorporated into Program WBMOD, which includes subroutines for computing both link geometry and scintillation indices, the latter by means of phase screen diffraction theory. Earlier versions of WBMOD, were based on extensive analysis of scintillation data collected in the auroral and equatorial zones in Wideband Satellite Mission. The model described herein is based on similarly extensive analysis of Wideband data from one mid latitude station and of data collected from HiLat satellite at another mid latitude station. The model describes irregularities at an effective height of 350 km that are isotropic across the geomagnetic field ...

1986-10-31

471

Metallic implants and exposure to radiofrequency radiation  

International Nuclear Information System (INIS)

There is increasing use of radiofrequency radiation (RFR) in industry for communications, welding, security, radio, medicine, navigation etc. It has been recognised for some years that RFR may interact with cardiac pacemakers and steps have been taken to prevent this interference. It is less well recognised that other metallic implants may also act as antennas in an RFR field and possibly cause adverse health effects by heating local tissues. There are a large and increasing number of implants having metal components which may be found in RFR workers. These implants include artificial joints, rods and plates used in orthopaedics, rings in heart valves, wires in sutures, bionic ears, subcutaneous infusion systems and (external) transdermal drug delivery patches"1. The physician concerned with job placement of such persons requires information on the likelihood of an implant interacting with RFR so as to impair health. The following outlines the approach developed in ...

472

Long-life bismuth liquid metal ion source for focussed ion beam micromachining application  

International Nuclear Information System (INIS)

Liquid metal ion sources (LMISs) with Ga as ion species are widely used in focused ion beam (FIB) technology for micromachining and surface treatment on the sub-micron and nano-scale. Key features of a LMIS for investigating mechanical properties and 3D-microfabrication of materials are long life-time, high brightness, stable ion current and a highly effective milling ability for the material to be modified. In order to increase the material removal rate, heavier ions than Ga and their clusters should be applied. Bismuth (Bi) is the heaviest, non-radio-active element in the periodic table, is non-toxic and exhibits a low melting point. We have thus produced a long-life (about 1000 h) Bi LMIS with a good beam performance, applicable in any FIB system. Since Bi is the only element in this source, it is not necessary to separate it from other ions by a mass filter. Investigation of the sputtering rate of NiTi shape memory alloys using Ga and Bi LMIS showed that, for ...

2008-09-15

473

Kinetic aspects of the photolysis of in-station airborne methyl iodide  

International Nuclear Information System (INIS)

A method for converting organic iodides to elemental iodine would be advantageous in improving the performance of charcoal filters for the removal of radio iodines from reactor off gases. A photochemical method has been developed. The HAVCHM code was used to establish the relevant process time scales on a complete set of rate equations describing the primary and secondary reactions occurring in a plug-flow reactor containing low levels of elemental iodine and methyl iodide in air, which is irradiated by intense u.v. light. These simulations were used to justify the contraction of the complete set of reactions to the most significant elementary processes. The contracted set of rate equations are then solved analytically to render the concentration-time profiles of methyl iodide, total inorganic iodine and total oxidized organics, consistent with the achievement of a desirable radioiodine decontamination factor. For the short contact times available, the flux of ...

474

Is the Supernova Remnant RX J1713.7-3946 a Hadronic Cosmic Ray Accelerator ?  

CERN Document Server

The non-thermal supernova remnant RX J1713.7-3946 (G347.3-0.5) has recently been shown to be a site of cosmic ray (CR) electron acceleration to TeV energies (Muraishi et al. 2000). Here we present evidence that this remnant is also accelerating CR nuclei. Such nuclei can interact with ambient interstellar gas to produce high energy gamma-rays via the decay of neutral pions. We associate the unidentified EGRET GeV gamma- ray source 3EG J1714-3857 with a massive (~3*10 5 Mo) and dense (~500 nucleons cm -3) molecular cloud interacting with RX J1713.7-3946. Direct evidence for such interaction is provided by observations of the lowest two rotational transitions of CO in the cloud; as in other clear cases of interaction, the CO(J=2-1)/CO(J=1-0) ratio is significantly enhanced. Since the cloud is of low radio and X-ray brightness, CR electrons cannot be responsible for the bulk of its GeV emission there. A picture thus emerges where both electrons and nuclei are being ...

2001-01-01

475

Instrumentation and Controls Division progress report, September 1, 1980-July 1, 1982  

Energy Technology Data Exchange (ETDEWEB)

Activities are reported by the Reactor Systems Section, Research Instrument Section, and the Measurement and Controls Engineering Section. Reactor system activities include dynamic analysis, survillanc and diagnostic methods, design and evaluation, detectors, facilities support, process instrumentation development, and special assignments. Activities in the Research Instrument Section include the Navy-ORNL RADIAC development program, advanced ..gamma.. and x ray detector systems, neutron detection and subcriticality measurements, circuit development, position-sensitive detectors, stand-alone computers, environmental monitoring-detectors and systems, plant security, engineering support for fusion energy division, engineering support for accelerator physics, and communications: radio, closed-circuit tv, and computer. Activities in the Measurement and Controls Engineering Section include the AVLIS program; gas centrifuge enrichment technology support; Advanced ...

1982-12-01

476

Influence of the Alfven wave spectrum on the scrape-off layer of the TCA tokamak  

International Nuclear Information System (INIS)

The study of the scrape-off layer (SOL) during Alfven wave heating may lead to a better understanding of the antenna-plasma interaction. The scrape-off layer of the TCA tokamak has been widely investigated by means of Langmuir probes. The aim of this work is to present measurements on the influence of the Alfven wave spectrum on the scrape-off layer. These experiments have shown that the plasma boundary layer is strongly affected by the wave field, in particular the ion saturation current and the floating potential. In TCA, as the spectrum evolves due to a density rise, the passage of the Alfven continua and their associated eigenmodes, the Discrete Alfven Wave (DAW) induces a strong depletion in the edge density of up to 70% during the continuum part and a density increase during the crossing of an eigenmode. The floating potential becomes negative during the continua and even more negative crossing the eigenmodes. In case of MHD mode activity, this behaviour changes for power ...

1988-05-01

477

Industrial applications of the Jefferson Lab high-power free-electron laser  

International Nuclear Information System (INIS)

In partnership with the US Navy, high-technology corporations, and research universities, Jefferson Lab is building a superconducting radio-frequency (SRF) accelerator-driven free-electron laser (FEL) and is outfitting an FEL user facility. This first fourth-generation light source - a 1 kW, 3 #mu#m infrared (IR) laser - is the first step in a program to develop high-average-power SRF-based IR and ultraviolet (UV) FELs for multiple manufacturing applications as well as for defense-related applied research and basic scientific research. This initial FEL will be driven by a 42 MeV, 5 m A recirculating SRF linac similar to the much larger SRF linac in Jefferson Lab's 4 GeV, 200 #mu#A Continuous Electron Beam Accelerator Facility (CEBAF). The FEL is expected to demonstrate 75% energy recovery. Its linac will be cooled by the existing CEBAF cryogenic system. At Jefferson Lab, an infrastructure of facilities and people already supports the advance of SRF and closely ...

1998-09-02

478

IN VACUUM UNDULATOR TASK FORCE REPORT  

Energy Technology Data Exchange (ETDEWEB)

The Green-Chasman lattice, which is the basis for both NSLS storage rings, was conceived with insertion devices in mind. Long, field-free straight sections were provided in the design. The electron optics were chosen so that these sections had zero dispersion and the effects of new magnetic structures placed in these regions would have minimal effect on the emittance of the electron beam. This design concept has been followed by all high-brightness rings which were built subsequent to the NSLS. The X-Ray Ring straight sections also have a very small vertical {beta} function, in addition to the zero dispersion. This was done to optimize the brightness of wiggler sources. There is a further benefit however. The {beta} function determines the beam size and divergence at a particular point in the storage ring lattice. The size is proportional to {radical}{beta} and the divergence is proportional to 1/{radical}{beta}. Thus the electron beam is very small at the center of the X-Ray Ring ...

1998-06-01

479

Gravitational waves interferometer and the VIRGO project  

CERN Document Server

Radio, optical and X-rays telescopes are improving our knowledge of deep space. All these telescopes detect electromagnetic radiation at various frequencies. But a different kind of radiation is generated in the deeper space; it is the gravitational one. Gravitational waves change the space-time metric. As a consequence, GW telescopes should detect an extremely small strain (h < 10/sup -21/) of the geometry of a reference frame; if the frame has a reference dimension (L) of some kilometers, the deformation amplitude ( Delta L = h * L) is limited to 10/sup -16/ meters. Laser interferometers are the most suitable devices to make precise measurements of distances. Their resolution is limited by the laser wavelength ( lambda = 10/sup -6/ meters) and by the light wave-shift detection capability ( Delta Phi = 1 ppb). These theoretical limits are strongly degraded by different noise sources, which reduce the actual resolution by several orders of magnitude. Applied ...

2002-01-01

480

FDTD analysis of body-core temperature elevation in children and adults for whole-body exposure  

Energy Technology Data Exchange (ETDEWEB)

The temperature elevations in anatomically based human phantoms of an adult and a 3-year-old child were calculated for radio-frequency whole-body exposure. Thermoregulation in children, however, has not yet been clarified. In the present study, we developed a computational thermal model of a child that is reasonable for simulating body-core temperature elevation. Comparison of measured and simulated temperatures revealed thermoregulation in children to be similar to that of adults. Based on this finding, we calculated the body-core temperature elevation in a 3-year-old child and an adult for plane-wave exposure at the basic restriction in the international guidelines. The body-core temperature elevation in the 3-year-old child phantom was 0.03 deg. C at a whole-body-averaged specific absorption rate of 0.08 W kg{sup -1}, which was 35% smaller than in the adult female. This difference is attributed to the child's higher body surface area-to-mass ratio.

2008-09-21

481

Extended Gas in Seyfert Galaxies Near Infrared Observations of NGC 2110 and Circinus  

CERN Document Server

We present results of near--IR long-slit spectroscopy in the J and K bands of the Seyfert 2 galaxies NGC 2110 and Circinus, investigating the gaseous distribution, excitation, reddening and kinematics. In NGC 2110, the emission line ratio [FeII]/Pa beta increases towards the nucleus (to ~ 7). The nuclear [Fe II]1.257 (microns) and Pa beta lines are broader (FWHM ~ 500 km/s) than the H2 (2.121) line (FWHM ~ 300 km/s). Both these results suggest that shocks, driven by the radio jet, are an important source of excitation of [Fe II]. The H2 excitation appears to be dominated by X-rays from the nucleus. In Circinus, both [FeII]/Pa beta and H2/Br gamma decrease from ~ 2 at 4 arcsec from the nucleus to nuclear values of ~ 0.6 and ~ 1, respectively, suggesting that the starburst dominates the nuclear excitation, while the AGN dominates the excitation further out (r > 2 arcsec). For both galaxies, the gaseous kinematics are consistent with circular rotation in the plane ...

1998-01-01

482

Enhancement of surface properties of 45{number_sign} steel using plasma immersion ion implantation  

Energy Technology Data Exchange (ETDEWEB)

45{number_sign} steel, which has good mechanical strength and is relatively cheap, is a common constituent in industrial components, such as precision gears, piston columns of oil pumps, and so on. However, since the working environment of these industrial parts is sometimes quite harsh and unforgiving, they are vulnerable to wear and corrosion. Replacing 45{number_sign} steel with stainless or alloy steel increases the cost significant, and a better alternative is to improve its surface properties and lifetime using plasma immersion ion implantation (PIII). The authors have devised a variety of treatment processes using PIII, including radio-frequency (RF) plasma nitriding, RF plasma nitriding and nitrogen PIII, Ti deposition in conjunction with nitrogen PIII (IBED), as well as Cr deposition followed by nitrogen PIII (IBED). To assess the efficacy of the processes, the microhardness and mass loss due to wear were measured for both the untreated and treated ...

1997-12-31

483

Electromagnetic radiation unmasked  

International Nuclear Information System (INIS)

This article describes the nature of the electromagnetic waves, what they are and how do they affect us. Current concern is focused on exposure to low level power-frequency magnetic fields like microwave radiation from mobile phones and leaking microwave ovens; high power radiation from defence and airport radars; fields close to high voltage transmission lines; radio frequency fields from industrial welders and heaters and DC magnetic fields in aluminium smelters. These fields with frequency less than 300 GHz do not carry sufficient energy to break chemical bonds and it is assumed that they cannot damage cell DNA. The amount of radiation absorbed by a human exposed to far field electromagnetic radiation (EMR) depends on the orientation and size of the person. In the 30-300 MHz range it is possible to excite resonance in the whole or partial body such as the head. It is emphasised that since there are some evidence that electromagnetic fields do harm, a policy of ...

1996-01-01

484

Difference Antenna Selection and Power Allocation for Wireless Cognitive Systems  

CERN Document Server

In this paper, we propose an antenna selection method in a wireless cognitive radio (CR) system, namely difference selection, whereby a single transmit antenna is selected at the secondary transmitter out of $M$ possible antennas such that the weighted difference between the channel gains of the data link and the interference link is maximized. We analyze mutual information and outage probability of the secondary transmission in a CR system with difference antenna selection, and propose a method of optimizing these performance metrics of the secondary data link subject to practical constraints on the peak secondary transmit power and the average interference power as seen by the primary receiver. The optimization is performed over two parameters: the peak secondary transmit power and the difference selection weight $\\delta\\in [0, 1]$. We show that, difference selection using the optimized parameters determined by the proposed method can be, in many cases of ...

2010-01-01

485

Development of swing-free / shock free crane  

Energy Technology Data Exchange (ETDEWEB)

To develop the automatized crane and to apply the relevant technology to nuclear power plants, in this project and automatized crane control system is developed along with a swing and shock crane. Also, this technology has been transferred to Bando Machinery Co. Ltd. The drive mechanism of crane is designed by adopting vector drives which provide soft acceleration and deceleration characteristics. Also, radio modems and a long-range laser displacement sensor which are commercially available are introduced to accommodate the large scaled crane systems. Also, several devices are developed for the automation of crane system. These are a crane controller, a supervisory controller, a angle measuring device, and laser localizer, a drum grapple device, and crane supervisory program. The performance of developed crane system is revealed to rapidly reduce the residual swingof the transported object and precisely controls the object position in any case. Also, the laser ...

1999-04-01

486

Computational AstroStatistics Fast and Efficient Tools for Analysing Huge Astronomical Data Sources  

CERN Document Server

I present here a review of past and present multi-disciplinary research of the Pittsburgh Computational AstroStatistics (PiCA) group. This group is dedicated to developing fast and efficient statistical algorithms for analysing huge astronomical data sources. I begin with a short review of multi-resolutional kd-trees which are the building blocks for many of our algorithms. For example, quick range queries and fast n-point correlation functions. I will present new results from the use of Mixture Models (Connolly et al. 2000) in density estimation of multi-color data from the Sloan Digital Sky Survey (SDSS). Specifically, the selection of quasars and the automated identification of X-ray sources. I will also present a brief overview of the False Discovery Rate (FDR) procedure (Miller et al. 2001a) and show how it has been used in the detection of ``Baryon Wiggles'' in the local galaxy power spectrum and source identification in radio data. Finally, I will look ...

2001-01-01

487

Collisional cooling of negative-ion beams  

Energy Technology Data Exchange (ETDEWEB)

Studies have been conducted to determine the feasibility of using collisional cooling for reducing emittances and energy spreads in negative-ion beams to levels commensurate with effective isobaric purification with conventional high-resolution electromagnetic isobar separators as required for use at the Holifield Radioactive Ion Beam Facility (HRIBF). We have designed a gas-filled radio frequency quadrupole ion cooler equipped with provisions for retarding energetic negative-ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to initial energies after the cooling process. The device has been used to cool several ion beams with initial energy spreads, {delta}E>10 eV to final energy spreads, {delta}E{approx}2 eV FWHM, including O{sup -} and F{sup -}. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been obtained. Experimental results show that electron detachment is the major loss ...

2002-01-01

488

CZT vs FFT: Flexibility vs Speed  

Energy Technology Data Exchange (ETDEWEB)

Bluestein's Fast Fourier Transform (FFT), commonly called the Chirp-Z Transform (CZT), is a little-known algorithm that offers engineers a high-resolution FFT combined with the ability to specify bandwidth. In the field of digital signal processing, engineers are always challenged to detect tones, frequencies, signatures, or some telltale sign that signifies a condition that must be indicated, ignored, or controlled. One of these challenges is to detect specific frequencies, for instance when looking for tones from telephones or detecting 60-Hz noise on power lines. The Goertzel algorithm described in Embedded Systems Programming, September 2002, offered a powerful tool toward finding specific frequencies faster than the FFT.Another challenge involves analyzing a range of frequencies, such as recording frequency response measurements, matching voice patterns, or displaying spectrum information on the face of an amateur radio. To meet this challenge most ...

2003-10-01

489

Behavior of the positron beam of the Super-ACO storage ring in response to a modification of the RF frequency for free-electron laser experiments  

International Nuclear Information System (INIS)

The macrotemporal structure of the Super-ACO Storage ring free-electron laser (FEL) can be either continuous, pulsed, or chaotic, and can present some rapid fluctuations. The temporal evolution of a storage ring FEL involves both the longitudinal motion of the positron beam (especially the synchrotron oscillations) and the FEL dynamics, as in a coupled system. Studies on the dynamics of the positron beam are performed here, in the goal to have a stable source for FEL applications, and to determine the conditions for a stable Q-switching experiment. The employed method is to study the influence of a controlled change of the radio frequency (RF) (modulation or frequency jump) on the beam. A simple theoretical model taking into account the perturbed RF system is presented to help the understanding of the experimental data. The different methods of measurement are described. Then, the results are given for several experimental conditions and the influence of different ...

490

Are HI Supershells the Remnants of $\\gamma$-Ray Bursts?  

CERN Document Server

Gamma-Ray Bursts (GRBs) are thought to originate at cosmological distances from the most powerful explosions in the Universe. If GRBs are not beamed then the distribution of their number as a function of gamma-ray flux implies that they occur once per (0.3-40) million years per bright galaxy and that they deposit >10^{53} ergs into their surrounding interstellar medium. The blast wave generated by a GRB explosion would be washed out by interstellar turbulence only after tens of millions of years when it finally slows down to a velocity of 10 km/s. This rather long lifetime implies that there could be up to several tens of active GRB remnants in each galaxy at any given time. For many years, radio observations have revealed the enigmatic presence of expanding neutral-hydrogen (HI) supershells of kpc radius in the Milky Way and in other nearby galaxies. The properties of some supershells cannot be easily explained in terms of conventional sources such as stellar ...

1998-01-01

491

Adaptive and mobile ground sensor array.  

Energy Technology Data Exchange (ETDEWEB)

The goal of this LDRD was to demonstrate the use of robotic vehicles for deploying and autonomously reconfiguring seismic and acoustic sensor arrays with high (centimeter) accuracy to obtain enhancement of our capability to locate and characterize remote targets. The capability to accurately place sensors and then retrieve and reconfigure them allows sensors to be placed in phased arrays in an initial monitoring configuration and then to be reconfigured in an array tuned to the specific frequencies and directions of the selected target. This report reviews the findings and accomplishments achieved during this three-year project. This project successfully demonstrated autonomous deployment and retrieval of a payload package with an accuracy of a few centimeters using differential global positioning system (GPS) signals. It developed an autonomous, multisensor, temporally aligned, radio-frequency communication and signal processing capability, and an array ...

2003-12-01

492

AGN Feedback: Does it work?  

CERN Document Server

While feedback is important in theoretical models, we do not really know if it works in reality. Feedback from jets appears to be sufficient to keep the cooling flows in clusters from cooling too much and it may be sufficient to regulate black hole growth in dominant cluster galaxies. Only about 10% of all quasars, however, have powerful radio jets, so jet-related feedback cannot be generic. The outflows could potentially be a more common form of AGN feedback, but measuring mass and energy outflow rates is a challenging task, the main unknown being the location and geometry of the absorbing medium. Using a novel technique, we made first such measurement in NGC 4051 using XMM data and found the mass and energy outflow rates to be 4 to 5 orders of magnitude below those required for efficient feedback. To test whether the outflow velocity in NGC 4051 is unusually low, we compared the ratio of outflow velocity to escape velocity in a sample of AGNs and found it to be ...

2009-01-01

493

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

Science.gov (United States)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. Supported by National Natural Science Foundation of China (10475112), Western Light Foundation of Chinese ...

2008-05-01

494

A rapid, radiometric assay for sucrose synthase  

Energy Technology Data Exchange (ETDEWEB)

Investigations of sucrose synthase in maize root tips have required development of a means to circumvent the rapid decline of activity observed after extraction dialysis and either synthetic or degradative assays. Several protease inhibitors were tested; although PMSF increased initial activity, no inhibitor prevented the drop in activity with time. Western blot analysis indicated that activity decline was not associated with protein degradation. Therefore, a procedure was developed which (1) shortened extraction-to-assay period from ca. 24 hours to 7 minutes, (2) simplified previous assays and (3) reduced the amount of tissue required. Extract was desalted with spun columns and the {sup 14}C-UDPG product recovered with DEAE ion exchange paper. The minute quantities of product recovered can be concealed by the presence of trace impurities in the {sup 14}C-sucrose utilized. DEAE ion exchange paper was used to remove interfering radio-labelled compounds from the {sup ...

1990-05-01

495

A numerical simulation of the evolution and fate of a FRI jet. The case of 3C 31  

CERN Document Server

The evolution of FRI jets has been long studied in the framework of the FRI-FRII dichotomy. In this paper, we test the present theoretical and observational models via a relativistic numerical simulation of the jets in the radio galaxy 3C 31. We use the parameters derived from the modelling presented by \\cite{lb02a,lb02b} as input parameters for the simulation of the evolution of the source, thus assuming that they have not varied over the lifetime of the source. We simulate about 10 % of the total lifetime of the jets in 3C 31. Realistic density and pressure gradients for the atmosphere are used. The simulation includes an equation of state for a two-component relativistic gas that allows a separate treatment of leptonic and baryonic matter. We compare our results with the modelling of the observational data of the source. Our results show that the bow shock evolves self-similarly at a quasi-constant speed, with slight deceleration by the end of the simulation, ...

2007-01-01

496

A Remarkable Low-Mass X-ray Binary within 0.1 pc of the Galactic Center  

CERN Document Server

Recent X-ray and radio observations have identified a transient low-mass X-ray binary (LMXB) located only 0.1 pc in projection from the Galactic center, CXOGC J174540.0-290031. In this paper, we report the detailed analysis of X-ray and infrared observations of the transient and its surroundings. Chandra bservations detect the source at a flux of F_X = 2e-12 erg cm^-2 s^-1 (2-8 keV). After accounting for absorption both in the interstellar medium and in material local to the source, the implied luminosity of the source is only L_X = 4e34 erg/s (2-8 keV; D=8 kpc). However, the diffuse X-ray emission near the source also brightened by a factor of 2. The enhanced diffuse X-ray emission lies on top of a known ridge of dust and ionized gas that is visible infrared images. We interpret the X-ray emission as scattered flux from the outburst, and determine that the peak luminosity of CXOGC J174540.0-290031 was >2e36 erg/s. We suggest that the relatively small observed ...

2005-01-01

497

A Plan to Diffuse Instructional Materials for Use by Transportation Educators.  

Science.gov (United States)

A plan to diffuse instructional modules for the preparation of transportation professionals is presented, based on research and demonstration projects sponsored by the Urban Mass Transportation Administration (UMTA). The diffusion/adoption plan involves: developing instructional modules; disseminating the modules to professors teaching transportation courses at the college level; promoting the use and adoption of the modules; and evaluating and revising the plan. Transportation educators teach in a variety of disciplines (e.g., engineering, public administration, urban planning, and technology). Eight design and evaluation criteria for the instructional modules are listed, along with the procedures used by West Virginia University in developing the five instructional modules. The diffusion strategy involves repackaging UMTA research findings, change agents, and the use of information channels (e.g, television/radio, periodicals, direct mail). Adoption tactics ...

1986-01-01

498

A MODEL OF THE SPECTRAL EVOLUTION OF PULSAR WIND NEBULAE  

International Nuclear Information System (INIS)

We study the spectral evolution of pulsar wind nebulae (PWNe) taking into account the energy injected when they are young. We model the evolution of the magnetic field inside a uniformly expanding PWN. Considering time-dependent injection from the pulsar and coolings by radiative and adiabatic losses, we solve the evolution of the particle distribution function. The model is calibrated by fitting the calculated spectrum to the observations of the Crab Nebula at an age of a thousand years. The spectral evolution of the Crab Nebula in our model shows that the flux ratio of TeV #gamma#-rays to X-rays increases with time, which implies that old PWNe are faint in X-rays, but not in TeV #gamma#-rays. The increase of this ratio is because the magnetic field decreases with time and is not because the X-ray emitting particles are cooled more rapidly than the TeV #gamma#-ray emitting particles. Our spectral evolution model matches the observed rate of the radio flux decrease ...

2010-06-01

499

A Cognitive Approach to Network Monitoring in Heterogeneous Environments  

DEFF Research Database (Denmark)

Introducing intelligence by means of cognition for managing, protecting, processing, and delivering of information in mobile communication systems is the way towards ubiquitous, converged and secure communications. In this context, this paper introduces the concept of quality of information (QoI). QoI means QoS while all the requirements for dependability, security, privacy and trust are satisfied at the highest possible level. This work proposes and describes an approach to network monitoring in a heterogeneous communication environment based on use of cognitive techniques and learning predictive algorithms (e.g., fuzzy logic). These methodologies are used to create an autonomy in the decision making process that is based on the calculation of key performance indicators (KPIs), which in their turn would trigger the needed radio resource management algorithms. The expected output is an improved network performance in terms of maximized throughput and faster ...

2007-01-01