Limestone slurry needs to move efficiently through a complex process, meaning that selecting the right pumps and valves is critical. The article discusses factors to consider in selecting pumps and values for flue gas desulfurization process in coal-fired power plants. 2 photos.
Comparison of plasma density increase was carried out in outer and inner channels of the interferometer in T-11M tokamak. There were two cases of gas puffing: by outer valve or upper one. Amplitude of difference of the plasma density increase consisted of 9% near the outer valve. Perturbation of the electric potential e?1/Te can have similar value. This perturbation can lead to appearance of the additional losses.
The calculation of nominal choke valve size determines the effective capacity for an oil and gas production system. The degree of restriction for the controlling area in the valve is a function of the surrounding geometry. In an orifice plate this is known as the 'velocity of approach' and can be used to determine the meter coefficient (C_m). This paper presents a technique for choke valves, based on the meter velocity of approach parameter, which can be used to predict the Valve Coefficient (C_v) for new trim designs. The prediction method uses a data trend based on a number of flow tests conducted on various trim characteristics. The resultant parametric equation is used to predict the C_v of a new trim geometry. The method relies on experimental data determined per IEC 60534-2-3, with calculations per IEC 60534-2-1. This paper further investigates the effect of varying upstream ...
In coke-oven operations flue-gasvalves are used to switch the regenerator function from rich gas firing to lean gas firing. Compared with the simple geometry of the other parts of the flow path, which comprise flues and regenerators, the narrow and winding passages of the flue-gasvalves give rise to relatively high losses in pressure. Without the construction of high (and therefore expensive) chimneys, this means that operating problems may well arise due the inadequate suction capacity. The project focused on the theoretical and experimental analysis of a coke-oven flue-gasvalve. The primary aim was to reduce the pressure drop through the valve without modifying its external geomerty. The internal flow characteristics created by different valve geometries under a variety of ...
Purpose: To enable safety reactor shut down upon occurrence of an abnormal excess pressure in a hydraulic control unit. Constitution: The actuation pressure for a pressure switch that generates a scram signal is set lower than the release pressure set to a pressure release valve. Thus, if the pressure of nitrogen gas in a nitrogen container increases such as upon exposure of the hydraulic control unit to a high temperature, the pressure switch is actuated at first to generate the scram signal and a scram valve is opened to supply water at high pressure to control rod drives under the driving force of the nitrogen gas at high pressure to rapidly insert the control element into the reactor and shut down it. If the pressure of the nitrogen gas still increases after the scram, the pressure release valve is opened to release the nitrogen gas at ...
The major bottleneck for popularization and utilization of the conventional mechanical valve pulse combustors is the self-priming mode of gas supply. An aerodynamic valve (as against mechanical valve) self-excited pulse combustor of the Helmholtz-type with continuous supply of gas and air was designed and a mathematical model was established in this paper. The theoretical model employed well-stirred reactor model and a single step Arrhenius chemistry, and took those factors which might affect the combustion stability into account. The factors include the variation of the mass rate of the reactants affected by the pressure in the combustion chamber, the convective and radiation heat loss in the combustion chamber, and the heat transfer and wall friction in the tailpipe. The effect of wall t...
In the design of natural gas compressor stations, a check valve is a critical element which is commonly placed on the discharge side of the compressor to prevent reverse flow that can cause serious damage to the compressor itself and other components such as seals and bearings. One of the selection criteria of the check valve for this particular application is the valve flow characteristics in steady flow, and its dynamic characteristics in unsteady flow operation. With regards to steady flow valve characteristics, current models for the determination of the check valve open angle vs. mean flow velocity are based on semi-empirical data obtained from water tests, which were found to deviate from measurements in compressible flows. This paper presents results of steady compressible flow testing of an NPS 4 swing type check valve in air. Mean ...
In the design of natural gas compressor stations, a check valve is a critical element which is commonly placed on the discharge side of the compressor to prevent reverse flow that can cause serious damage to the compressor itself and other components such as seals and bearings. One of the selection criteria of the check valve for this particular application is the valve flow characteristics in steady flow, and its dynamic characteristics in unsteady flow operation. With regards to steady flow valve characteristics, current models for the determination of the check valve open angle versus mean flow velocity are based on semi-empirical data obtained from water tests, which were found to deviate from measurements involving fluids of relatively higher compressibility. This paper presents results of steady flow testing of an NPS 4 swing-type check ...
In a PWR type reactor, a primary coolant circuit system using a steam generator is adopted in order to accelerate depressurization of a primary coolant circuit upon small rupture LOCA in which the pressure of the primary coolant circuit is moderately depressurized. A secondary coolant circuit depressurization valve is disposed to a main steam pipeline. The valve has a performance of automatically opening to remove heat by evaporation of water stored in SG for a short period of time when the pressure in the primary circuit is decreased to about 50kg/cm[sup 2] upon occurrence of LOCA or the like. Then, the secondary side of the SG is depressurized to about atmospheric pressure and gravitational water injection from a condensate tank is started. Further, a gas vent valve is disposed to a water chamber of the steam generator. The valve has a performance of automatically opening to ...
The risk perception of the public consists of two components: the objectively factual component and the subjectively irrational component. The two strategies adopted by the German gas supply industry are the internal and the external communication strategy. Concepts and measures of accident precaution, registration and analysis of accident data (installation and operating errors, defects on flue systems, pipelines and valves, subsequent installation of gas appliances) are discussed. (R.P.)
Object: To minimize the range of the liquid level variation of the cooling system and reduce the time required for the liquid level control by sealing the gas of a cover gas respiration system which acts upon an evaporator and pump overflow column. Structure: In liquid level control by the cover gas pressure of a high-speed reactor secondary cooling system, upon occurrence of a sudden change in the rate of flow of the recirculated liquid, automatic check valves provided in an evaporator and pump overflow column cover gas respiration system are completely or substantially closed, while at the same time the recirculation cooling medium is sucked up and an automatic check valve provided in the overflow system is closed. (Kamimura, M.).
Sigma 1) examines ways to reduce the number of breakdowns of pressure-regulating stations and to minimize the energy consumed in warming the gas, 2) determines the optimal gas temperatures upstream from the pressure reduction, and 3) shows the dependence of energy consumption upon the water dewpoint. The method of calculating the optimal input temperature relies on Mollier's diagram. Tables and nomographs for natural gas and water dewpoint at 19/sup 0/F and 580 psi (-7/sup 0/C and 4 MPa) are useful in achieving the desired gas temperatures. Heating the regulators' control valves is important.
This patent describes a gas-diesel dual fuel engine apparatus having a diesel engine, a diesel fuel supply system including a diesel fuel injection pump, a gaseous fuel supply system including gaseous fuel regulating valve, and a governing and controlling device for governing the speed of the engine and controlling the switchover of the operation of the engine between a diesel fuel mode and a gaseous fuel mode.
X-Plain Heart Valve Replacement Reference Summary Introduction Sometimes people have serious problems with their heart valves. A heart valve repair or ...
Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 {mu}Sv/y, collective dose: 1 man{center_dot}Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 {mu}Sv per year and 0.166 man{center_dot}Sv per year about H-beam, and 158 {mu}Sv per year and 0.468 man{center_dot}Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance level.
Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 #mu#Sv/y, collective dose: 1 man#centre dot#Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 #mu#Sv per year and 0.166 man#centre dot#Sv per year about H-beam, and 158 #mu#Sv per year and 0.468 man#centre dot#Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance level.
An apparatus for measuring the overall decontamination factors of first and second filters located in a plenum. The first filter separates the plenum's upstream and intermediate chambers. The second filter separates the plenum's intermediate and downstream chambers. The apparatus comprises an aerosol generator that generates a challenge aerosol. An upstream collector collects unfiltered aerosol which is piped to first and second dilution stages and then to a laser aerosol spectrometer. An intermediate collector collects challenge aerosol that penetrates the first filter. The filtered aerosol is piped to the first dilution stage, diluted, and then piped to the laser aerosol spectrometer which detects single particles. A downstream collector collects challenge aerosol that penetrates both filters. The twice-filtered aerosol is piped to the aerosol spectrometer. A pump and several valves ...
This patent describes a solar heater freeze protection valve apparatus comprising in combination: a valve housing; a remote sensor operatively connected to the valve housing from a remote position, the remote sensor including a bulb containing a liquid adapted to compress and expand with the temperature adjacent the bulb; a piston located in the valve body and slidable responsive to expansion and contraction of the liquid in the remote sensor; a first valve element located in the valve housing and attached to the valve piston for movement; a second valve element located in the valve housing and attached to the housing; a first valve seat in the second valve element forming an opening; a second valve seat positioned in a water passageway ...
Object: To prevent a sudden drop in the level of a coolant in a annular pipe encased within a downcomer pipe. Structure: The coolant levels in annular pipes encased within downcomer pipes are simultaneously measured by level gauges which generate signals representative of coolant levels. The signals are fed to a level control system which will actuate valves to regulate the cover gas pressure in order to average the level differences among the annular pipes in different downcomer pipes. (Kamimura, M.).
The objective of the program is to develop a domestic cooktop with low-NOx emissions and high efficiency. During the first two phases of the program, three design concepts were developed, and two versions of developmental prototypes using the IR-Jet approach were fabricated and tested. The third phase was initiated to address the design issues of burner turndown and modulation and to conduct the field test of a prototype with one IR-Jet and three conventional burners. Two prototypes containing one IR-Jet and three conventional burners and utilizing blower speed control for air/gas modulation were fabricated. One unit employed a brushless dc motor and the other a 2-pole ac motor. The ac motor prototype was field tested. Field testing showed the need for a mechanical air/gasvalve for modulation and for a 1500 Btu/hr simmer setting. A 4-inch-diameter stepped-tile configuration provided input rates from 1500 to 8000 Btu/hr. A ...
Valve Flow Characteristics. 3-68. 3-40. Valve Operating Current Vs. Temperature ...... VALVE FLOW CHARACTERISTICS. Acceptance Test 4/29/74. SINs 002 & 004 ...
Shut Down System - 2 (SDS - 2) of TAPP-3 and 4 works on the principle of rapid injection of gadolinium nitrate poison solution into bulk moderator in calandria using high pressure helium to shut down the reactor. This is a new system, in the context of Indian PHWRs, designed, engineered, commissioned and being operated in TAPP-3 and 4. The system design incorporates passive features such as floating polyethylene ball with ball-ball seat arrangement and locked open isolation ball valves with key interlock arrangement. This arrangement eliminates active valves downstream of poison tanks during SDS - 2 actuation. A series parallel arrangement of fast acting pilot controlled air operated valves, which keep the high pressure helium isolated from poison tanks in poised state, are the only active components. During commissioning and initial period of operation of TAPP-4, problems were encountered and were resolved by suitable ...
Device for separating and collecting ultrafine atomized powder from the gas stream of a gas atomizing apparatus comprises a housing having an interior wall oriented at an angle relative to horizontal so as to form a downwardly converging, conical expansion chamber, an inlet conduit communicated to the expansion chamber proximate an upper region thereof for receiving the gas stream, and an outlet proximate a lower region of the expansion chamber. The inlet conduit is oriented at a compound inclined angle (with respect to horizontal) selected to promote separation and collection of powder from the gas stream in the expansion chamber. The compound angle comprises a first entrance angle that is greater than the angle of repose of the powder on the housing interior wall such that any powder accumulation in the inlet conduit tends to flow down the wall toward the ...
This paper is a quarterly report describing the use of a new soil gascollection device which allows the collection of soil gas in the field for later analysis in the laboratory. It describes the installation of this sampling device and the procedure for setting the probe, extraction of soil gas beneath the surface, and sealing of the soil gas for transport. The sites used for initial testing was the top of Yucca Mountain and Crystal Spring in Ash Meadows National Wildlife Refuge. The results from this initial test showed no volatile matter present in the soil at these locations.
The goal of GRI's Gas Appliance Technology Center is to encourage the introduction of highly efficient, cost-effective, convenient gas appliances for residential and commercial gas users. The report covers activity at Battelle from February 1989 to April 1990 in broad support tasks, residential and commercial appliances, and residential space conditioning. Broad support tasks included the G/A/S Newsletter; the GATC InfoBase; and technology transfer, workshops, and GATC coordination. Residential appliance tasks included burner technology research, gas appliance venting, gas lighting, and plastics durability. Commercial appliance tasks included development of a commercial cooktop fuel/air mixing valve. Residential space conditioning tasks included a corrosion test method for gas appliances and vents, generic ...
This paper studies on the modelling of a butterfly-type control valve actuating by an on-off pneumatic solenoid valve. The mathematical model is composed of nonlinear differential equations three parts: (i) a solenoid valve, (ii) a pneumatic cylinder, (iii) a rotary-type butterfly valve. The flow characteristics of the butterfly control valve is analysed by a computer simulator, then its simple transfer function is identified from the step responses.
Oil and gas production and processing operations sometimes cause naturally occurring radioactive materials (NORM) to accumulate at elevated concentrations in by-product waste streams. The sources of most of the radioactivity are isotopes of "2"3"8U and "2"3"2Th series, which are naturally present in the subsurface formations from which oil and gas are produced. NORM waste may cause problems in the operations of installations by plugging perforations, clogging tubular and valves then restricting flow. Therefore, plants or equipment have to be refurbished and decontaminated before reuse to avoid radioactive waste or surface contaminated object. There are two options for safe disposal of scale and sludge produced from NORM Descaling Facility : 1- Injection into an abandoned production well. 2- The construction of a near surface depository. These options are assumed to be environmental friendly disposal options. (author)
Complete text of publication follows. Baikal is an ancient unique lake. The sweet water of Baikal is crystal clean; it concentrates oxygen and contains scarce silicon. This feature is provoked very particular interest for scientists and poses some awkward questions concerning the preservation of Baikal's ecosystem. A profound investigation of fish otholiths, animal teeth, sponges, valves of mollusks and diatom algae provides chronological information, possibility to reconstruct the events proceeding in the environment based on variations of their chemical composition. Because these study objects are small-sized, and some of them are micron-size, application of the electron-probe microanalysis turns to be quite productive. The goal of this study is to disclose performance capabilities of this method while investigating the Baikal flora and fauna. Investigations were performed by devices JCXA-733 and JXA-8200 using the electron microscope and x-ray microprobe modes. ...
The fault detection and diagnosis system for gas engines was developed to improve the reliability of cogeneration systems (CGS). Most of existing fault detection systems monitor the trend of each part condition of engines and diagnose faults based on trend change, resulting in slow detection. Although early detection systems are available, those are complex, expensive and poor in flexibility and applicability. Since CGSs combined with gas engines increased to 1/3 of the whole CGS, engine troubles cause possible serious faults. The fault diagnosis system was thus developed to prevent serious faults which can early detect, in particular, abnormal conditions of parts around a combustion chamber such as ignition plug, intake valve and exhaust valve by monitoring exhaust pressure waveforms in an exhaust collector. Since this system can detect progressive occurrence frequency of abnormal conditions and ...
To carry out studies on the radon behavior under controlled and stable conditions it was designed and constructed a system that consists of two parts: a container of mineral rich in Uranium and an experimentation chamber with radon united one to the other one by a step valve. The container of uranium mineral approximately contains 800 gr of uranium with a law of 0.28%; the radon gas emanated by the mineral is contained tightly by the container. When the valve opens up the radon gas it spreads to the radon experimental chamber; this contains 3 accesses that allow to install different types of detectors. The versatility of the system is exemplified with two experiments: 1. With the radon experimental chamber and an associated spectroscopic system, the radon and two of its decay products are identified. 2. The design of the system allows to couple the mineral container to other experimental geometries to ...
A schematic of the Bench cavity receiver system is given, and the primary objectives, schedule and research plan for each of four tests are discussed. The tests are: (1) cold flow testing to functionally check all valves and their response using high pressure nitrogen gas; (2) a hot checkout to simulate both steady state and transient flux inputs to the receiver which are expected at the French facility; (3) basic performance using solar energy at the French facility; and (4) ir radiant heat testing. (LEW)
The fuel-injection system of the Niigata 6L 16X-AG dual-fuel engine is structured to steadily supply injected fuel during diesel-engine operation, and to distribute oil at a low rate to all the cylinders during gas-engine operation. The dual-fuel engine is started by the diesel engine operation and is changed over to gas-engine operation when the load increases. This change over is done automatically with a link mechanism. Regarding the gas-supply system, the changing pressure of supply gas is controlled by a pressure control valve which is stable and most adequate for the engine. The dual-fuel engine has the following features: (1) a high compression ratio is adopted, which reduces fuel consumption and thermal efficiently; (2) if the supply of gas decreases or stops, while continuing loaded operations, it can immediately shift to diesel engine operation ...
BACKGROUND AND AIM OF THE STUDY: Abnormal flow conditions across aortic bioprosthetic valves may result in degenerative processes. Thus, it is important to implant biological valve prostheses with velocity profiles similar to those of native valves. The study aim was to compare blood velocity and velocity gradient profiles downstream of stented and stentless aortic valves implanted in pigs, and in native porcine valves. METHODS: Stented valve prostheses (Mitroflow, n = 7) or stentless valve prostheses (Solo, n = 5 or Toronto SPV, n = 7) were implanted into pigs; the native valve was retained in eight animals. After weaning the animals from cardiopulmonary bypass, cardiac magnetic resonance imaging was performed to determine the blood velocities and velocity gradient profiles. RESULTS: The native ...
Waste tank W-12 is a tank in the ORNL Low-Level Liquid Waste (LLLW) system that collected waste from Building 3525. Because of a leaking flange in the discharge line from W-12 to the evaporator service tank (W-22) and continual inleakage into the tank from an unknown source, W-12 was removed from service to comply with the Federal Facilities Agreement requirement. The initial response was to decontaminate the valve pit between tank W-12 and the evaporator service tank (W-22) to determine if personnel could enter the pit to attempt repair of the leaking flange. Preventing the spread of radioactive contamination from the pit to the environment and to other waste systems was of concern during the decontamination. The drain in the pit goes to the process waste system; therefore, if high-level liquid waste were generated during decontamination activities, it would have to be removed from the pit by means other than the available liquid waste ...
The simulation of the Auxiliary Charcoal Bed (ACB) Vacuum System was performed to evaluate the original vacuum system design, detect and identify design deficiencies, investigate the effects of proposed corrections on system performance, and generally aid in refining the system design before construction and mockup testing. The simulation was performed by using the Advanced Continuous Simulation Language (ACSL). The vacuum system design goals are to provide approximately 20 SCFM of both booster gas and purge gas through the system and maintain a flow of approximately 40 SCFM with a velocity of 50 to 75 f/sec at the entrance to the cyclone separator. The model results showed that the original system design was incapable of meeting the system performance goals. Further simulations showed that the following modifications to the original vacuum system design were required to make the system performance acceptable; (1) Remove ...
A flexible and computationally economical model of the internal combustion engine was developed for use on large digital computer systems. It is based on a system of ordinary differential equations for cylinder-averaged properties. The computer program is capable of multicycle calculations, with some parameters varying from cycle to cycle, and has restart capabilities. It can accommodate a broad spectrum of reactants, permits changes in physical properties, and offers a wide selection of alternative modeling functions without any reprogramming. It readily adapts to the amount of information available in a particular case because the model is in fact a hierarchy of five models. The models range from a simple model requiring only thermodynamic properties to a complex model demanding full combustion kinetics, transport properties, and poppet valve flow characteristics. Among its many features the model includes heat transfer, valve timing, ...
This patent describes in an dual gas-liquid fuel four cycle engine having cylinders and wherein each cylinder is operatively connected thereto and each cylinder has a piston, two inlet valves, two exhaust valves and a first liquid fuel injector. It comprises: at least one fuel torch cell operatively connected to at least one cylinder, the torch cell having a torch cell nozzle at one end thereof and the other end having appropriate means to connect the torch cell to a fuel supply, a second fuel injector mounted in the torch cell at a predetermined angle to an axis of the torch cell, the torch cell defining an auto-ignition chamber, the second fuel injector being in operative communication with the auto-ignition chamber by an injector nozzle passageway, the injector nozzle passageway entering the auto-ignition chamber at a predetermined angle relative to the axis, and a torch nozzle passage connecting the auto-ignition ...
The tube bundle arrangement is suitable as reheating section of a steam generator in combination with a gas-cooled reactor. For any high-temperature section with a straightline type tube bundle, there is one inlet and one outlet collecting main; these two are arranged one opposite to the other and diametrically to the tube bundle. There are a number of lines from the inlet collecting main to the outlet collecting main; these lines are arranged axially one on top of the other and run around the tube bundle helically several times. (GL) 891 GL/GL 892 MB.
The current status of research and development in the realm of physics and technology of collective ion acceleration in systems with a virtual cathode (VC) is reviewed. Three major acceleration methods and devices developed on their basis are considered: reflex triodes and their modifications, gas-filled vircators, and vacuum vircators with a Luce diode. Experimental data are outlined and the principal physical models interpreting these data are described. New ion acceleration techniques whose realization involves the production and disappearance of the VC are also discussed. All methods of collective ion acceleration are compared and the possible ways for the further development of this promising scientific field are highlighted. (reviews of topical problems)
Trace gas molecules absorb specific wavelengths of incoming solar ... These data(with information collected from similar experiments carried on balloons, rockets, ... The ATMOS sensor instrumentis a state-of-the-art version of a 19th century ...
The multicell proportional chambers at the backing calorimeter of the ZEUS experiment at the storage ring HERA are supplied with a gas mixture of Ar/CO[sub 2] by an open gas system. Flow proportional counters with the build-up [sup 55]Fe sources are used as gas system monitoring detectors. The ZEUS experiment is planned to collect data for about 10 years. Therefore, the lifetime of the Ar/CO[sub 2] mixture should be known. In this paper, the results of laboratory tests and preliminary measurements of the aging effects for monitoring counters are presented. ((orig.))
Nowadays, percutaneous pulmonary valve implantation is a successful alternative to surgery for patients requiring treatment of pulmonary valve dysfunction. However, owing to the wide variety of implantation...Full Text Available
A butterfly valve is a type of flow control device, typically used to regulate a fluid flowing. Currently, FEA is often used to predict the safety in the design of valve disc. Also, the study about the affection of butterfly valve's disc to the valve flow characteristics by using CFD has been done by many researchers. Along with the development of computer technique, design and analysis of computer experiments has becoming more and more important in engineering design and optimization. Hereinto Kriging model is one popular analysis approach for the purpose of creating a cheap ``meta-model'' as a surrogate to a computationally expensive simulation model. In this paper, the numerical analysis considered the strength, pressure loss coefficient and weight of valve disc simultaneously is investigated to improve the shape of a traditional butterfly valve disc. ...
This report presents the results of the design testing of large (36-inch diameter) butterfly valves under high flow conditions. The two butterfly valves were pneumatically operated air-open, air-shut valves (termed valves 1 and 2). These butterfly valves were redesigned to improve their ability to function under high flow conditions. Concern was raised regarding the ability of the butterfly valves to function as required with high flow-induced torque imposed on the valve discs during high steam flow conditions. High flow testing was required to address the flow-induced torque concerns. The valve testing was done using a heavily instrumented piping system. This test program was called the Large Scale Steam Valve Test (LSSVT). The LSSVT program demonstrated that the redesigned ...
This paper presents the application of hydraulic network analysis to evaluate the performance of butterfly valves in nuclear power plant applications. Required actuation torque for butterfly valves in high-flow applications is often dictated by peak dynamic torque. The peak dynamic torque, which occurs at some intermediate disc position, requires accurate evaluation of valve flow rate and pressure drop throughout the valve stroke. Valve flow rate and pressure drop are significantly affected by the valve flow characteristics and the hydraulic system characteristics, such as pumping capability, piping resistances, single and parallel flow paths, system hydrostatic pressure, and the location of the motor-operated valve (MOV) within the system. A hydraulic network analysis methodology that addresses the effect of these parameters on the MOV ...
Concerning the transient phenomenon of solid-gas two-phase flow, an attempt was made to visualize and measure a flow phenomenon in which three-dimensional bubbles occurred, grew and collapsed in the vicinity of a gas injection nozzle while solid particles were circulating. Such a phenomenon could not or hardly be visualized and measured by conventional methods. Such two-phase flow was visualized using neutron radiography, its characteristics measured and the usefulness of the visualization by neutron radiography confirmed. For this purpose, three-dimensional fluidized bed vessels, rectangular or cylindrical-shaped, made of steel or aluminum sheet, were prepared. Polyethylene or glass beads were used as solid particles and activated carbon particles as the tracer. In the experiment, nitrogen gas was blown into the vessel from one nozzle and distributors provided at the bottom of the vessel and exhausted from the top via the ...
One of the energy-saving devices used on gas cooking appliances to eliminate the standing pilot is a spark ignition system. For safety, an ignition system must start promptly and be active whenever flowing gas is not ignited. To minimize noise and nuisance shock hazard, ignition must occur quickly and the sparking must be stopped as soon as ignition occurs and remain off as long as the flame is present. To accomplish both of these requirements, ignition systems have been devised which use the electrical current rectification property of a flame to sense it. These systems spark whenever the gasvalve is on and a flame is not present. The factors affecting the performance of a spark ignition system are numerous, complex, and transient. All of these properties make quantification of performance difficult. A system is described which can evaluate the overall performance of ignition systems over significant ...
Butter-fly valves are advantageous over gate, globe, plug, and ball valves in a variety of installations, particularly in the large sizes. The purpose of this project development of linear flow rate control system for eccentric butter-fly valve (intelligent butter-fly valve system). The intelligent butter-fly valve system consist of a valve body, micro controller. The micro controller consist of torque control system, pressure censor, worm and worm gear and communication line etc. The characteristics of intelligent butter-fly valve system as follows: Linear flow rate control function. Digital remote control function. guard function. Self-checking function. (author)
Improved separation of heavier material from a dispersoid of gas and heavier material entrained therein is taught by the method of this invention which advantageously uses apparatus embodied in an inertial separator having rotary partition means comprising wall members dividing a housing into a plurality of axially-extending through passages arranged in parallel. Simultaneously with the helical transit of a moving stream of the dispersoid through the parallel arrangement of axially-extending through passages at a constant angular velocity, the heavier material is driven radially to the collecting surfaces of the rotational wall members where it is collected while the wall members are rotating at the same angular velocity as the moving stream. The plurality of wall members not only provides an increased area of collecting surfaces but the positioning of each of the wall members according to the teaching ...
Visible smoke of exhaust gas from iron ore sintering plants spoil the scenery around the works. In this paper, the mechanism of formation of visible smoke is discussed by detailed analysis of the exhaust gas components and dust in the Oita No. 1 sintering plant. The main substance of visible smoke was mist condensing in the air during the cooling of exhaust gas that contained 0.1 ppm of sulfuric acid. Sulfuric acid is considered to raise the dew point and so facilitate mist condensation, and to lower the vaporization of visible mist containing sulfuric acid solution. Dust in the exhaust gas is also considered to act as nucleation sites for mist condensation. This proposed mechanism was confirmed by the test remixing SOx-rich gas with desulfurization gas in the Nagoya No. 3 sintering plant. Long trails of visible smoke were observed by remixing SOx-rich ...
An automotive powertrain includes a conventional piston engine, a continuously variable ratio transmission, an engine speed sensor and a feedback control system. The control system adjusts both the transmission ratio and the throttle valve in the engine carburetor or fuel metering system in response to the position of the accelerator pedal and in response to the crankshaft speed as measured by the engine sensor. The transmission provides extreme overdrive gear ratios which allow the engine to be operated at wide open throttle even during moderate cruising, and, in addition, the engine carburetor or fuel metering system is calibrated to deliver to the engine a stoichiometric air-fuel mixture which is combined, before combustion, with a special proportion of recirculated exhaust gas. As a result of extensive wide open throttle engine operation with the above mentioned intake charge composition, combustion variables are optimized to produce ...
This manual is intended to provide a guide to the use of the Flue Gas Desulfurization Information System (FGDIS) data base which is a collection of data files consisting of information pertaining to the design and performance of flue gas desulfurization (FGD) systems. The files are stored at the U.S. Environmental Protection Agency National Computer Center (NCC), Research Triangle Park, NC. Access to these files and manipulation of the data therein is accomplished via System 2000, general data base management system developed by INTEL Corp. and supported by the NCC Univac 1100 hardware.
One of the characteristic safety features of a pool type research reactor is a safety flapper valve. The valve enables natural convection cooling mechanism in one of the following events. (a) Opening flapper valve promote decay heat removal following reactor's shutdown. (b) Also the valve is gravity driven. There is a possibility that the valve fails to open when it is required to do so. In the present paper the cooling characteristics of the core are analyzed for this event. A steady state study was performed for 5 MW power and 18 FE following a reactor shutdown. It is shown that enough margin exists to assure adequate reactor core cooling should the safety flapper valve fails to open. (authors)
Object: To permit a valve operation test to be periodically made during plant operation without causing variations in plant power by detecting flow control valve defect on the basis of a valve aperture alteration instruction. Structure: Step signals which are equal in absolute value and opposite in sign are coupled to the input side of flow controllers provided on the recycling loops of two or more recycling flow control systems. With these inputs the aperture of the flow control valve on one side is increased (or reduced) while the aperture of the valve on the other side is reduced (or increased). As a result, the recycling flow rate in the loop on one side is increased (or reduced) while that on the other side is reduced (or increased). Whether the valve is normally operating or not is confirmed by checking the recycling flow rate and ...
An Experimental study was performed to investigate flow characteristic of multi-stage expansion valve applied with inverter heat pump. Multi-stage expansion consists of parallel valve which is controlled on/off type of solenoid valve. Expansion valve open one solenoid the other closed in low frequency region and open two solenoid valve in high frequency region. In rated frequency region always open one solenoid valve and control period and on-off time ratio for the other solenoid valve. Flow characteristics of a orifice expansion was measured as a function of orifice diameter and operating conditions. As a results multi-stage expansion device can control a stable flow with period and on-off time ratio. (author). 4 refs., 7 figs., 1 tab.
ObjectiveWe sought to determine the clinical outcomes of patients undergoing surgical aortic valve replacement with hemodynamically confirmed severe pulmonary hypertension and aortic stenosis and compare them with the outcomes of patients not undergoing aortic valve replacement and patients undergoing aortic valve replacement with mild-to-moderate pulmonary hypertension. MethodsA total of 317 patients with severe aortic stenosis (aortic valve area 35 mm Hg) was present in 81 patients, of whom 35 (43.2%) underwent surgical aortic valve replacement. We compared the clinical outcomes of these 35 patients with the 46 patient...
The control valve for a large steam turbine must be operated linearly to be run by an automatic control system in a power plant. It is, however, found that the flow increase is much greater for a given valve position change near the closed end of travel than it is near the open end. Accordingly, the desired linearization will be achieved if the valve is opened less near the closed end of travel and greater near the open end. The previous way for linearization was to utilize the cams, which is called the mechanical hydraulic control (MHC). The MHC was afterward improved by producing the nonlinear electric compensation to the nonlinear system of control valves, viz. the electro hydraulic control (EHC)
The control valve for a large steam turbine must be operated linearly to be run by an automatic control system in a power plant. It is, however, found that the flow increase is much greater for a given valve position change near the closed end of travel than it is near the open end. Accordingly, the desired linearization will be achieved if the valve is opened less near the closed end of travel and greater near the open end. The previous way for linearization was to utilize the cams, which is called the mechanical hydraulic control (MHC). The MHC was afterward improved by producing the nonlinear electric compensation to the nonlinear system of control valves, viz. the electro hydraulic control (EHC)
A gas-diesel dual fuel engine apparatus is described having a diesel engine, a diesel fuel supply system including a diesel fuel injection pump, a gaseous fuel supply system including a gaseous fuel regulating valve, and a governing and controlling device for governing the speed of the engine through the control of fuel supplied to the engine and controlling the switchover of the operation of the engine between a diesel fuel mode and a gaseous fuel mode. The improvement of the governing and controlling device consists of: (a) at least one electronic governor means adapted to compare a speed signal representing the actual operating speed of the diesel engine with a set speed signal representing the set speed thereof; (b) a pair of electric actuator means having respective power amplifier circuits and mechanically connected to the diesel fuel injection pump and the gaseous fuel regulating valve, respectively, for the ...
This paper describes the design and feasibility tests of a 570 mm bore 4 stroke low pressure (L.P.) dual fuel engine rated at 20.9 bar BMEP meant for the propulsion of LNG carriers. The basic design features which are to be in accordance with classification societies safety rules are described: individual electro hydraulic valves located in the air manifold ducts, pilot injection, monitoring system etc. The engine capability to burn variable liquid/gas fuel proportions have been investigated with diesel oil and heavy fuel and possible running zones are defined. This ensures the possibility of the engine to cope with the different boil off gas quantity emanating from the ship`s tank during her loaded - and ballast - journeys. With the very lean setting of this engine, no adverse influence of the high ash lube-oil additives were found during the tests. Further tests are necessary to confirm that possible more significant ...
Liquid pipeline codes generally stipulate placement of block valves along liquid transmission pipelines such as on each side of major river crossings where environmental hazards could cause or are foreseen to potentially cause serious consequences. Codes, however, do not stipulate any requirement for block valve spacing for low vapour pressure petroleum transportation, nor for remote pipeline valve operations to reduce spills. A review of pipeline codes for valve requirement and spill limitation in high consequence areas is thus presented along with a criteria for an acceptable spill volume that could be caused by pipeline leak/full rupture. A technique for deciding economically and technically effective pipeline block valve automation for remote operation to reduce oil spilled and control of hazards is also provided. In this review, industry practice is highlighted and application ...
The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Bjoerk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic ...
The energy recovery scheme at Mucking Marshes landfill site, operated by Cory Environmental Limited, has been in operation since October 1991. Using landfill gas abstracted from the site, a gas turbine generates up to 3.2 MW net electric power for export. Operation and performance of the scheme has been monitored over the period January 1995 to August 1996. Overall performance since the first use of the turbine has also been studied, and has shown reliable and profitable operation. The capital cost of the gas turbine and gas compressor plant was approximately 1.8 million. Actual gascollection wells, pipework, pumping and monitoring facilities, while essential to the scheme, are considered part of the gas control equipment needed for the landfill site. Based on a notional electricity selling price of 4p/kWh, the current annual income from ...
Typical beam lines are comprised of an assembly of vacuum valves and shutters referred to as a ''front end'', optical elements to monochromatize, focus and split the photon beam, and an experimental area where a target sample is placed into the photon beam and data from the interaction is detected and recorded. Windows are used to separate sections of beam lines that are not compatible with storage ring ultra high vacuum. Some experimental beam lines share a common vacuum with storage rings. Sections of beam lines are only allowed to vent up to atmospheric pressure using pure nitrogen gas after a vacuum barrier is established to protect ring vacuum. The front end may only be bled up when there is no current in the machine. This is especially true on the VUV storage ring where for most experiments, windows are not used. For the shorter wavelength, more energetic photons of the x-ray ring, beryllium windows are ...
The PDIM multifunction regulator offers in one single unit the basic functions filtering, slamshut safety valve, pressure reduction and a gas flow straightening vane. This concept formulated by the engineer J.-P. Cornil is a Gaz de France patent. Developed and manufactured by a French industrial company it incorporates some astute innovations in the field of fluid dynamics. Its technical caracteristics make a significant step forward in gas technology. Since the first unit was brought into service over 1000 PDIM units have been built and incorporated in gas regulating and metering stations for transport, distribution and industrial applications. The very compact nature of the PDIM enhanced by its direct bolting to a turbine or other type of gas meter leads to small size stations allowing lower cost projects and making it easier to set in populated or architecturally significant ...
The purpose of this study is to extend the knowledge base for wetland treatment to include processes and substances of particular importance to small, on-site systems receiving oil and gas well waste water. Collection of data on the sorption of heavy metals and the degradation of toxic organics is one of the key tasks. The toxic organics phenolics and anthracene, and chromium and copper have been selected as target adsorbates. An information search was performed on oil refinery waste treatment wetland systems.
Tarapur Atomic Power Station Unit-4 is first 540 MWe pressurized heavy water reactor in India. It achieved criticality on 06th March 2005 and then operated at full power i.e 500 MWe. Radiation workers during the normal operation and reactor shutdown are exposed to radiation field. The control of dose rates and the collective dose of the radiation workers is most important for the best performance of the reactor. Experience gained during the operation of the 220 MWe reactors has shown that the Moderator system, primary heat transport system, annulus gas system and moderator cover gas system are the main systems contributing to the dose rate and collective dose. In order to identify the radio nuclides contributing to the radiation field, study was undertaken at TAPS Unit-4. Various samples from the Moderator, primary heat transport system, annulus gas system and moderator cover ...
This paper discusses the evolution of the horizontal subsea tree and its utilization in increasingly demanding applications. Initially, the Horizontal Tree was seen as a solution for wells requiring high well maintenance, such as those using electrical downhole pumps. Today, the horizontal tree is being applied to natural drive wells because of attractive whole life economics. This raises concern in a number of areas. Tubing hanger seals are permanently exposed to well fluids, and must provide high integrity sealing. This required the development of a new type of radially energized, all metal sealing system, specifically for horizontal tree applications, suitable for oil or gas service at working pressures to 15,000 psi. In addition, horizontal tree pressure integrity depends on the master valve stem, gate and bonnet seals. The need for high seal integrity also dictates that the first master valves should be integral to the ...
The metal parts of cardiac valve prostheses cause reactions in the surrounding tissues of the heart. In some dogs rather abnormal reactions were found, and were attributed to corrosion of the stainless...Full Text Available
The new percutaneous mitral valve repair techniques are at an early stage. Preliminary series show that they are feasible; however, they need to be further evaluated in comparison with contemporary...Full Text Available
Blunt chest-wall trauma is common; however, resultant tricuspid valve rupture is rare and can be subtle in its presentation. Transthoracic echocardiography plays a key role in diagnosis.Herein,...Full Text Available
AimsTranscatheter treatment of heart valve disease is well established today. However, for the treatment of tricuspid regurgitation (TR), no effective catheter-based approach is...Full Text Available
This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of ...
This report discusses environmental surveillance activities conducted on the Nevada Test Site during the first calendar quarter of 1996. Surveillance activities included collection and analysis of air, noble gas, tritiated water vapor, and other water samples. Samples were analyzed for both radiological and non-radiological effluents.
The free energy of a gas of closed strings with extrinsic curvature (smooth strings) is evaluated on a torus. This is compared with the free energy of a collection of free particles, and hence the mass spectrum of excitations of the smooth strings is deduced. It is found that above a critical value of the coupling constant of the curvature term the spectrum is free of tachyons. Furthermore, there are no massless spin-2 excitations. The absence of massless spin-2 fields is a consequence of the fact that the smooth-string theory is not modular invariant.
The University of Groningen (RUG) has developed an expert system on cleaning of biomass producer gas. This work was carried out in close co-operation with the Biomass Technology Group B.V. (BTG) in Enschede, The Netherlands within the framework of the EC supported JOR3-CT95-0084 project. The expert system was developed as a tool for the designer-engineer of downstream gas cleaning equipment and consists of an information package and a flowsheet package. The packages are integrated in a client/server system. The flowsheeting package of the expert system has been designed for the evaluation of different gas cleaning methods. The system contains a number of possible gas cleaning devices such as: cyclone, fabric filter, ceramic filter, venturi scrubber and catalytic cracker. The user can select up to five cleaning steps in an arbitrary order for his specific gas cleaning problem. After ...
end of the barrel. The petal valve and ring seal are inserted behind it, and the gun barrel assembly and HP section are clamped together with hydraulic collars. ...
Some motor operated valves now have higher torque switch settings due to regulatory requirements to ensure valve operability with appropriate margins at design basis conditions. Verifying operability with these settings imposes higher stem loads during periodic inservice testing. These higher test loads increase stresses in the various valve internal parts which may in turn increase the fatigue usage factors. This increased fatigue is judged to be a concern primarily in the valve disks, seats, yokes, stems, and stem nuts. Although the motor operators may also have significantly increased loading, they are being evaluated by the manufacturers and are beyond the scope of this study. Two gate valves representative of both relatively weak and strong valves commonly used in commercial nuclear applications were selected for fatigue analyses. Detailed dimensional and ...
Response of control valves plays an important role in the dynamics of the flow system as a whole. Knowledge of its transfer function would facilitate analysis of the behaviour of the system. This paper presents the application of Levy's complex curve fitting method for determination of the transfer function of control valves used in Liquid Zone Control System of 540 MWe PHWR. (author)
In order to evacuate the residual power in a nuclear reactor, a thermal valve system is presented for the modification of the heat exchange conditions at the pool exchanger level, which avoids the use of mechanical valves on the pipes. The system involves a vessel containing the exchanger, with openings at the upper end of the vessel and means for feeding the fluid at the lower end, and means for controlling the opening width.
The purpose of the project is to further develop a Danish natural gas reformer system including optimisation of subsystems and the overall system consisting of a natural gas reformer and fuel cell CHP generator. This will contribute to the evaluation of to what extend Denmark shall develop small reformer units for PEM fuel Cells. In the project a reformer system with a high degree of automatic control has been build that fulfils the CHP requirements to operation time, dynamics etc. This work, with a FP05 reformer unit, has given valuable results concerning the possibilities and limitations of the reformer technology for CHP usage. It is important that the reformer and fuel cell units are designed with matching yields to optimise efficiency, turn-down start-up time etc. The burner that delivers heat for the steam reaction shall be able to use natural gas as fuel. This gives the possibility of using existing burner ...
Ordos Basin, the second largest sedimentary basin in China, contains enormous natural gas resources. Each of the four giant gas fields discovered so far in this basin (i.e., Sulige, Yulin, Wushenqi and Jingbian) has over 100 billion cubic meters (bcm) or 3.53 trillion cubic feet (tcf) of proven gas reserves. This study examines the stable carbon isotope data of 125 gas samples collected from the four giant gas fields in the Ordos Basin. Source rocks in the Upper Paleozoic coal measures are suggested by the generally high {delta}{sup 13}C values of C{sub 2}-C{sub 4} gaseous hydrocarbons in the gases from the Sulige, Yulin and Wushenqi gas fields. The {delta}{sup 13}C values of methane, benzene and toluene in gases from the Lower Paleozoic reservoirs of the Jingbian field indicate a significant contribution from humic source rocks, as they are ...
Indoor and soil gas Radon (222Rn) concentration measurements were accomplished in two stages in Sivas, a central eastern city in Turkey. In the first stage, CR-39 passive nuclear track detectors supplied by the Turkish Atomic Energy Authority (TAEA) were placed in the selected houses throughout Sivas centrum in two seasons; summer and winter. Before the setup of detectors, a detailed questionnaire form was distributed to the inhabitants of selected houses to investigate construction parameters and properties of the houses, and living conditions of inhabitants. Detectors were collected back two months later and analysed at TAEA laboratories to obtain indoor 222Rn gas concentration values. In the second stage, soil gas 222Rn measurements were performed using an alphameter near the selected h...
The purpose of this rulemaking is to amend the effluent limitations guidelines and standards for the control of discharges of certain pollutants associated with the use of synthetic-based drilling fluids (SBFs) and other non-aqueous drilling fluids in portions of the Offshore Subcategory and Cook Inlet portion of the Coastal Subcategory of the Oil and Gas Extraction Point Source Category. These proposed limitations apply to discharges or effluent generated when oil and gas wells are drilled using SBFs or other non-aqueous drilling fluids (collectively referred to simply as SBFs) in coastal and offshore regions in locations where drilling wastes may be discharged.
Today, as a result of increase in oil prices, limited fossil fuel resources, environmental consideration and global warming, the methyl ester fuels have been focused on alternative fuels. Methyl ester fuels can be used more efficiently in low heat rejection engines (LHR), in which the temperature of combustion chamber is increased by creating a thermal barrier. In this study, the piston, cylinder head, exhaust and inlet valves of a diesel engine were coated with the ceramic material Al{sub 2}O{sub 3}-TiO{sub 2} by the plasma spray method. Thus, a thermal barrier was provided for the parts of the combustion chamber with these coatings. The effects of corn oil methyl ester that produced by the transesterification method, and No. D2 fuels' performance and exhaust emissions' rate were studied by using equal in every respect coated and uncoated engines. Tests were performed on the uncoated engine, and then repeated on the coated engine and the results ...
This paper introduces marketability and parts application of PBT in the automotive field. Based on the pursuits in automobiles of weight reduction as measures to improve engine performance, drive performance, and fuel consumption, as well as trends of higher class car orientation, market expansion is expected on engineering resins including PBT. Adoption of PBT/polycarbonate (PC)-based alloy resins is on increase for use in external car parts because of the chemical resistance in PBT, low-temperature shock resistance and appearance of PC. Substitution from Nylon resin in connector application is progressing rapidly because of problems in dimensional stability and compound noise. Air bag sensor parts need to be free of maloperation due to contamination and corrosion in metal contacts caused from gases generated from formed parts, hence development of resins of low gas generation grade is wanted. Valves for exhaust control require ...
Zinc oxide thin films were obtained by laser ablation of a Zn target in oxygen reactive atmosphere, the oxygen being supplied either by a standard gas inlet valve or from a radio-frequency (rf) oxygen plasma. Pt-coated silicon and MgO were used as substrates. The influence of the deposition parameters as laser wavelength (266, 355, 1064 nm), laser fluence (1.5-20 J/cm2) and oxygen pressure (1-60 Pa) was studied. The influence of the rf plasma beam addition on the morphological proprieties of zinc oxide films was particularly investigated, simultaneously with several configurations of the direction of the ablation plasma, the rf plasma beam and the substrate. The obtained films, with thicknesses in the range of 50 nm to 1 ?m have been characterized by atomic force microscopy (AFM), X-ray diffraction (XRD), transmission electron microscopy (TEM).
All of the project work since the previous report has been on Phase 2B tasks. Therefore, this quarterly progress report summarizes the period's activities in Engineering, Procurement and Civil Construction. Engineering is 95% complete, but revisions and changes are still being incorporated particularly in the Instrument and Electrical areas. Procurement has only valves 4 in. and above yet to order to complete all major items purchased. The scheduled material curve was based on the original estimate of the job. The projected curve reflects the previous month's estimate. Construction of civil work is proceeding according to schedule in the field. The initial bid packages for the Mechanical General Contractor portion of the work have been reviewed and evaluated. Order placement is scheduled for the end of July. The Electrical package is due back from the bidders on July 6. It requires additional evaluation by BSC and DSO and will not be placed until ...
The control valve for a large steam turbine must be operated linearly to be run by an automatic control system in a power plant. It is, however, found that the flow increase is much greater for a given valve position change near the closed end of travel than it is near the open end. Accordingly, the desired linearization will be achieved if the valve is opened less near the closed end of travel and greater near the open end. The previous way for linearization was to utilize the cams, which is called the mechanical hydraulic control (MHC). The MHC was afterward improved by producing the nonlinear electric compensation to the nonlinear system of control valves, viz. the electro hydraulic control (EHC). This paper addresses the principle of linearization.
The control valve for a large steam turbine must be operated linearly to be run by an automatic control system in a power plant. It is, however, found that the flow increase is much greater for a given valve position change near the closed end of travel than it is near the open end. Accordingly, the desired linearization will be achieved if the valve is opened less near the closed end of travel and greater near the open end. The previous way for linearization was to utilize the cams, which is called the mechanical hydraulic control (MHC). The MHC was afterward improved by producing the nonlinear electric compensation to the nonlinear system of control valves, viz. the electro hydraulic control (EHC). This paper addresses the principle of linearization.
As usual a shipping terminal contains a header and its diameter is smaller than the main pipeline diameter. This diameter reduction amplifies the effects caused by hydraulic transients. It was noticed during simulations that check valves without dynamic modeling may introduce some error in the maximum pressure results without a dynamic model approach. The current paper uses commercial pipeline simulation software to model the dynamic behavior of the check valves. It was studied the header diameter influence and how the check valve model type may change the maximum pressure in the pipeline. It was proved that even a pipeline that works with low pressure and small elevation drop needs a detailed valve modeling to prevent the calculation of unreal pressure values in the region with diameter reduction. (author)
Gas storage is a critical element in the natural gas industry. Producers, transmission and distribution companies, marketers, and end users all benefit directly from the load balancing function of storage. The unbundling process has fundamentally changed the way storage is used and valued. As an unbundled service, the value of storage is being recovered at rates that reflect its value. Moreover, the marketplace has differentiated between various types of storage services and has increasingly rewarded flexibility, safety, and reliability. The size of the natural gas market has increased and is projected to continue to increase towards 30 trillion cubic feet over the next 10 to 15 years. Much of this increase is projected to come from electric generation, particularly peaking units. Gas storage, particularly the flexible services that are most suited to electric loads, is crucial in meeting the needs of ...
During the first and second quarters of 1994 air samples were collected and analyzed from 54 air particulate/halogen sampling stations, 10 noble gas sampling stations and 19 tritiated water vapor sampling stations. Surface water samples were collected and analyzed from 12 open water supply reservoirs, 8 natural springs, 2 wastewater containment ponds and 9 sewage lagoons. Groundwater samples were obtained brom 10 potable and 1 non-potable supply wells, and 8 drinking water consumption points. Ambient radiation levels were measured at 193 locations.
The iron foundry industry is considered to be a potential source of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). This study investigated the emission factors and total emission amounts of PCDD/Fs and dioxin-like polychlorinated biphenyls (DL-PCBs) from iron foundries in China. The concentrations and the World Health Organization toxicity equivalents (WHO-TEQs) are presented and the congener profiles are discussed in this paper. In the present work, 26 fly ash samples were collected and tested to quantify the PCDD/Fs and DL-PCBs generated by 14 plants of different scales, and five stack gas samples were collected from two (named as EFG and LFG) of those plants. The emission levels of PCDD/Fs and DL-PCBs indicated that hot-air cupolas had lower emissions than cold-air cupol...
Having know of four more natural hot spring located in Amphur Phipun, Nakorn Si Thammarat Province, the present investigators went on July 27, 2005 to collect water samples from the four new hot springs in Ampur Phipun, Nakorn Si Thammarat Province. The methods of collection and the determination of radon gas and free-living amoeba were the same as those employed in previous studies. The results revealed radon concentrations higher than the drinking safety limits of 11 Bq/L in specimens from Baan Huaysai Kow (32.30 Bq/L) and Baan Hunob (31.18 Bq/L; both naegleria and acanthamoeba were present in the specimens of the above two sites, whereas only naegleria recovered from Baan Huaysai Kow (Nai Nukul place) and none from Baan Nong Bua.
A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with the detector are ...
A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with the detector are ...
Biomass is a potential source of energy that can reduce our dependency on oil as the main source of energy. In addition to municipal solid waste, animal and olive wastes are the main sources of organic waste in Jordan. In 2005, there were more than 2.4 million heads of sheep, about 72 thousand cows, and 40 million hens being raised in farms distributed in all governorates of Jordan. These animals produce 5.3 million tons (as exerted) of solid waste per year. If these quantities can be effectively collected they may constitute a valuable source of energy. This paper is aiming to estimate the amounts of animal and solid wastes generated in Jordan and their energy potential. The total amount of BOD from animal waste is estimated at 200,000 tons per year. Significant quantities of organic waste can also be collected from olive mills distributed in the country. This waste known locally as ''Jift'' is currently ...
This Guideline provides a set of procedures for the measurement of organic contaminants and particles in producer gases from biomass gasifiers. The procedures are designed to cover different gasifier types (updraft or downdraft fixed bed or fluidised bed gasifiers), operating conditions (0 - 900C and 0.6-60 bars) and concentration ranges (1 mg/m{sub n}{sup 3} to 300 g/m{sub n}{sup 3}). The Guideline describes a modular sampling train, and a set of procedures, which include: planning and preparation of the sampling, sampling and post-sampling, analysis, calculations, error analysis and reporting. The modular sampling train consists of 4 modules. Module 1 is a preconditioning module for isokinetic sampling and gas cooling. Module 2 is a particle collection module including a heated filter. Module 3 is a tar collection module with a gas quench (optionally by circulating a liquid), impinger bottles and a ...
In this study, liquid flame spray (LFS) was used to produce titania, silver and silver-titania deposits of nanoparticles. Titanium(IV)ethoxide (TEOT) and silver nitrate in ethanol solutions were used as precursors and sprayed into turbulent hydrogen-oxygen flame. Production rates of 1.5-40 mg/min of titania were used with silver additions of 1, 2, 4, and 8 wt% compared to titania. Nanoparticle deposits were collected by thermophoretic sampling at six different axial distances from the flame torch head: 3, 5, 10, 12, 15, and 20 cm, of which the all but the last one occurred inside the flame. The deposit samples were analysed by TEM and SAED analysis. The powder samples of the particles were also collected by electric precipitator to XPS and specific surface area analysis. Particle size and effective density after the flame in the aerosol were analysed with SMPS and ELPI. The results from the previous studies i.e. controlling the particle size by ...
The data and information collected for the Public Service Electric and Gas Company`s (PSE&G) electric vehicle demonstration program were intended to support and enhance DOE`s Electric and Hybrid Vehicle Site Operator Program. The DOE Site Operator Program is focused on the life cycle and reliability of Electric Vehicles (EVs). Of particular interest are vehicles currently available with features that are likely to be put into production or demonstrate new technology. PSE&G acquired eight GMC Electric G-Vans in 1991, and three TEVans in 1993, and conducted a program plan to test and assess the overall performance of these electric vehicles. To accomplish the objectives of DOE`s Site Operator`s test program, a manual data collection system was implemented. The manual data collection system has provided energy use and mileage data. From September 1991 to October 1994 PSE&G logged 69,368 miles ...
A novel system has been deployed to obtain geochemical samples of water and gas, at in situ pressure, during a geologic CO2 sequestration experiment conducted in the Frio brine aquifer in Liberty County, Texas. Project goals required high-frequency recovery of representative and uncontaminated aliquots of a rapidly changing two-phase (supercritical CO2-brine) fluid from 1.5 km depth. The datasets collected, using both the liquid and gas portions of the downhole samples, provide insights into the coupled hydro-geochemical issues affecting CO2 sequestration in brine-filled formations. While the basic premise underlying the U-Tube sampler is not new, the system is unique because careful consideration was given to the processing of the recovered two-phase fluids. In particular, strain gauges mounted beneath the high-pressure surface sample cylinders measured the ratio of recovered brine to supercritical CO2. A quadrupole mass ...
Indoor and soil gas Radon ({sup 222}Rn) concentration measurements were accomplished in two stages in Sivas, a central eastern city in Turkey. In the first stage, CR-39 passive nuclear track detectors supplied by the Turkish Atomic Energy Authority (TAEA) were placed in the selected houses throughout Sivas centrum in two seasons; summer and winter. Before the setup of detectors, a detailed questionnaire form was distributed to the inhabitants of selected houses to investigate construction parameters and properties of the houses, and living conditions of inhabitants. Detectors were collected back two months later and analysed at TAEA laboratories to obtain indoor {sup 222}Rn gas concentration values. In the second stage, soil gas {sup 222}Rn measurements were performed using an alphameter near the selected houses for the indoor measurements. Although {sup 222}Rn concentrations in Sivas were quite low in ...
The industrial standard process for the purification of natural gas is to remove acid gases, mainly hydrogen sulfide and carbon dioxide, by the absorption and reaction of these gases with alkanolamines. The natural gas industry requires vapor-liquid equilibrium (VLE) data to develop more energy efficient amine mixtures. Some energy reductions have been realized in the past decade by applying such amine systems as hindered amines, methyldiethanolamine (MDEA), and MDEA based amine mixtures. However, the lack of reliable and accurate VLE data impedes the commercial application of these more efficient alkanolamine systems. The first objective of this project is to improve the accuracy of vapor-liquid equilibrium measurements at low hydrogen sulfide concentrations. The second objective is to make VLE measurements for amine mixtures. By improving the accuracy of the VLE data on MDEA and other amines, energy savings can be implemented in the many ...
The Power Systems Development Facility (PSDF) is a joint Department of Energy/Industry sponsored engineering-scale facility for testing advanced coal-based power generation technologies. High temperature, high pressure gas cleaning is critical to many of these advanced technologies. Barrier filter elements that can operate continuously for nearly 9000 hours are required for a successful gas cleaning system for use in commercial power generation. Since late 1999, the Kellogg Brown & Root Transport reactor at the PSDF has been operated in gasification mode. This paper describes the test results for filter elements operating in the Siemens-Westinghouse particle collection device (PCD) with the Transport reactor in gasification mode. Operating conditions in the PCD have varied during gasification operation as described elsewhere in these proceedings (Martin et al, 2002).
In an attempt to overcome inadequacies perceived in the approach to providing energy to village communities using the conventional Khadi and Village Industries Commission biogas plant as well as the Janata model, a biogas digester has been developed suitable for a farmer having only one hectare of land. The information on gas yields and other data from a variety of substrates in a laboratory digester are presented. The digester itself consists of a chamber underground into which the influent flows through a channel. Gas is collected in a dome which constitutes the upper part of the digestion chamber and is maintained under pressure by water. The dome can be made of any suitable material such as plastic, ferrocement and brick and mortar. The upper part of the chamber itself is exposed to sun light which enhances microbial growth. Water which surrounds the dome ensures a minimum of temperature variation. 3 references.
There is a need to reduce air pollutant emissions in some U.S. urban regions to meet federal and state air quality guidelines. Opportunities exist for reducing pollutant emissions from natural gas appliances in the residential sector. A cost-benefit analysis on various pollutant-reducing strategies is needed to evaluate these opportunities. The effectiveness of these pollutant-reducing strategies (e.g., low-emission burners, energy conservation) can then be ranked among themselves and compared with other pollutant-reducing strategies available for the region. A key step towards conducting a cost-benefit analysis is to collect information on pollutant emissions from existing residential natural gas appliances. An extensive literature search was conducted to collect data on residential natural-gas-appliance pollutant emission factors. The literature primarily describes laboratory ...
Gasification experiments were performed using urban waste wood (Altholz) with additions of polymers typical for separately collected waste plastics. The resulting tar product distributions are discussed in this paper. The amount of tars is shown to be a function of operation parameters of the gasifier as well as the fuel. Plastics admixture yields higher concentrations of aromatic tar compounds in the gases, even if the plastic used is not aromatic in its structure. Such mixtures can be gasified for the production of synthesis gas, but clearly a larger effort will be required in cleaning the gases. (author)
Radian Corporation was contracted to investigate duct injection and ESP phenomena in a 1.7 MW pilot plant constructed for this test program. This study was an attempt to resolve problems found in previous studies and answer remaining questions for the technology using an approach which concentrates on the fundamental mechanisms of the process. The goal of the study was to obtain a better understanding of the basic physical and chemical phenomena that control: (1) the desulfurization of flue gas by calcium-based reagent, and (2) the coupling of an existing ESP particulate collection device to the duct injection process. Process economics are being studied by others. (VC)
Radian Corporation was contracted to investigate duct injection and ESP phenomena in a 1.7 MW pilot plant constructed for this test program. This study was an attempt to resolve problems found in previous studies and answer remaining questions for the technology using an approach which concentrates on the fundamental mechanisms of the process. The goal of the study was to obtain a better understanding of the basic physical and chemical phenomena that control: (1) the desulfurization of flue gas by calcium-based reagent, and (2) the coupling of an existing ESP particulate collection device to the duct injection process. Process economics are being studied by others. (VC)
This paper describes a novel Fourier transform infrared (FTIR) spectroscopic method that can be used to rapidly screen soil samples from potentially hazardous waste sites. Samples are heated in a thermal desorption unit and the resultant vapors are collected and analyzed in a long-path gas cell mounted in a FTIR. Laboratory analysis of a soil sample by FTIR takes approximately 10 minutes. This method has been developed to identify and quantify microgram concentrations of explosives in soil samples and is directly applicable to the detection of selected volatile organics, semivolatile organics, and pesticides.
A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).
A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).
CRE is the French commission for energy regulation. CRE's remit is to assist in ensuring the proper operation of the electricity and natural gas markets for the benefit of the end-user. In particular, CRE ensures that the conditions of access to electricity and natural gas transmission and distribution systems do not hinder the development of competition. It monitors, for the electricity and natural gas sectors, all transactions made between suppliers, traders and producers, all transactions made on the organised markets and cross-border trading. It ensures that suppliers, traders and producers propose offers that are consistent with their financial and technical constraints. It monitors the implementation of and compliance with regulations giving consumers the right to choose their supplier in a competitive market, and allowing new suppliers to enter the market. This document is the 2008 activity report of CRE. ...
Artifical valve prostheses are often regarded as a contraindication for magnetic resonance imaging (MRI), although preliminary in vitro studies suggested, that patients with these metallic implants might safely undergo MR examination. This study reports on the experience with a group of 89 patients with 100 heart valve prostheses who were examined by spin-echo MR and gradient-echo MR. MR examination was performed in all patients without complications. The spin-echo sequence showed advantages in the depiction of anatomical structures like paravalvular abcesses. Anatomical structures adjacent to the artificial valve were clearly visivle and the metal components of the valves showes no or only small artifacts. Artifacts were accentuated when using gradient-echo sequences. Gradient-echo sequences provided valuable information regarding the presence of valvular insufficiency. Physiological valvular ...
The nitric acid solution dissolving nuclear fuel material is transferred with the three way valve called VCV (VCV: vide-casse-vide in Fr.) using vacuum in the Tokai Reprocessing Plant. The initial VCV was not reliable because it had broken with in 1 or 2 years. The cause of failure was damage of the plastic diaphragms in the moving parts. Then, the new VCV valve with stainless-steel bellows was developed. There is no failure in moving parts in 20 years, therefore reliability is significantly improved. (author)
An experimental study was performed to provide the combustion and emission characteristics resulting from fuel-reactivity controlled compression ignition (RCCI) combustion mode utilizing dual-fuel approach in a light-duty, multi-cylinder diesel engine. In-cylinder fuel blending using port fuel injection of gasoline before intake valve opening (IVO) and early-cycle, direct injection of diesel fuel was used as the charge preparation and fuel blending strategy. In order to achieve the desired auto-ignition quality through the stratification of the fuel-air equivalence ratio ( ), blends of commercially available gasoline and diesel fuel were used. Engine experiments were performed at an engine speed of 2300rpm and an engine load of 4.3bar brake mean effective pressure (BMEP). It was found that significant reduction in both nitrogen oxide (NOx) and particulate matter (PM) was realized successfully through the RCCI combustion mode even without applying exhaust ...
Part 2 of this manual provides the electric utility engineer with detailed technical information on some of the major mechanical equipment used in the FGD system. The objectives of Part 2 are the following: to provide the electric utility engineer with information on equipment that may be unfamiliar to him, including ball mills, vacuum filters, and mist eliminators; and to identify the unique technique considerations imposed by an FGD system on more familiar electric utility equipment such as fans, gas dampers, piping, valves, and pumps. Part 3 provides an overview of the recommended procedures for evaluating proposals received from FGD system vendors. The objectives are to provide procedures for evaluating the technical aspects of proposals, and to provide procedures for determining the total costs of proposals considering both initial capital costs and annual operating and maintenance costs. The primary objective of Part 4 of this manual is ...
The spectrum of training aids used in the nuclear industry runs the gamut from the very basic (i.e., valve training aids - gate, globe, check) to the highly complex (i.e., nuclear full scope simulator). Designing and purchasing the best training aids take much time, detailed investigation, and good understanding of plant operations. The training aid that has given the New York Power Authority the best results has been the motor operator valve (MOV) trainer. Some of the items that make the MOV trainer a good choice are: (1) large number of MOVs in the plant, (2) importance of MOVs to safe plant operation, (3) detailed MOV procedures used by the plant, (4) history of MOV problems, and (5) ability to demonstrate important concepts and operation - hammer blow effect, torque and limit switch adjustment and functions, and actual sequence of operation of the limitorque valve operator.
... The other standards in this group deal with heat exchangers, insulation, marking, valves, hydraulic cleanliness, storage of LPG, and centrifugal fire ...
Color Doppler flow mapping (CDFM) was performed in 47 normal women ages 18-41 mean (m) 28 to determine the normal flow phenomena across each of the 4 heart valves. The group included: 15 elite marathon runners average run (ave.) 70 miles/week, heart rate (HR) 35-54 (m 45); 14 joggers ave. 40 mi/wkm HR 40-69 (m 53); and 17 controls 0 mi/wk, HR 49-93 (m 77). 2-D echo and CDFM defined the motion of each valve, including the presence of mitral valve prolapse (MVP), the ventricular inflow and outflow patterns and the presence of regurgitation.
Purpose: To secure the reactor operation safety by the provision of a fluid pressure detecting section for control rod driving fluid and a control rod interlock at the midway of the flow pass for supplying driving fluid to the control rod drives. Constitution: Between a driving line and a direction control valve are provided a pressure detecting portion, an alarm generating device, and a control rod inhibition interlock. The driving fluid from a driving fluid source is discharged by way of a pump and a manual valve into the reactor in which the control rods and reactor fuels are contained. In addition, when the direction control valve is switched and the control rods are inserted and extracted by the control rod drives, the pressure in the driving line is always detected by the pressure detection section, whereby if abnormal pressure is resulted, the alarm generating device is actuated to warn the abnormality and the ...
As part of the EPRI Motor-Operated Valve (MOV) Performance Prediction Methodology, a System Flow Model (SFM) has been developed to determine the differential pressure (DP) across MOVs as they are stroked in typical power plant systems. Input to the SFM includes valve flow characteristics (such as flow coefficient) and system characteristics (such as pump head/flow curve). The primary output is differential pressure across the valve at each stroke position. The SFM was validated by comparison with test data from the EPRI Flow Loop Test Program. In this study, we calculated DP using SFM and performed DP test for four MOVs. Compared between calculated DP and test DP of four MOV, respectively good agreements are found. (author). 6 refs., 9 figs., 1 tab.
This work describes the radon in soil gas measurements performed during the last two years in cooperation between the Laboratory of Applied Nuclear Physics of the Federal University of Technology (UTFPR), the Nuclear Technology Development Center (CDTN) and the Institute of Radiation Protection and Dosimetry (IRD) from the Brazilian Nuclear Energy Commission (CNEN). Following previously concluded measurements of radon concentration in dwellings and the measurements of 222Rn activity in drinking water collected at artesian bores of Curitiba urban area, present step of activities has been dedicated to measurements of radon concentration in soil gas. Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specially developed for such measurements Soil Gas Probe through the air pump and filter system. After the Probe was inserted, the ground has been tamped down around the ...
The first radon soil gas survey in Serbia, using passive detectors (SSNTD, CR-39), was carried out in June 2005 at field sites in Niska Banja town. The aim of the survey was to identify risk zones characterised by high levels of this radioactive gas. Radon measurements were made at the depth of 50 cm, in the ground according to a systematic grid pattern. Furthermore, at all 48 measurement points, the surface gamma dose rates in the air was also measured at the same locations and soil samples were collected for gamma spectrometric analysis for the radionuclides {sup 226}Ra, {sup 228}Th and {sup 40}K. Radon concentrations were found to range from 1270 to 155000Bqm{sup -3} with an average of 33765Bqm{sup -3} and a median value of 12626Bqm{sup -3}. The geometrical mean value and geometrical standard deviation were calculated as 16160Bqm{sup -3} and 3.5Bqm{sup -3}, respectively. Gamma dose rate varies from 92 to 316nGyh{sup -1}, ...
The first radon soil gas survey in Serbia, using passive detectors (SSNTD, CR-39), was carried out in June 2005 at field sites in Niska Banja town. The aim of the survey was to identify risk zones characterised by high levels of this radioactive gas. Radon measurements were made at the depth of 50 cm, in the ground according to a systematic grid pattern. Furthermore, at all 48 measurement points, the surface gamma dose rates in the air was also measured at the same locations and soil samples were collected for gamma spectrometric analysis for the radionuclides "2"2"6Ra, "2"2"8Th and "4"0K. Radon concentrations were found to range from 1270 to 155000Bqm"-"3 with an average of 33765Bqm"-"3 and a median value of 12626Bqm"-"3. The geometrical mean value and geometrical standard deviation were calculated as 16160Bqm"-"3 and 3.5Bqm"-"3, respectively. Gamma dose rate varies from 92 to 316nGyh"-"1, with an average of 132nGyh"-"1. ...
The further optimisation and improvement of the efficiency of internal combustion engines require the realisation of new technologies leading to a distinctively faster warm-up behaviour of the coolant and lubricants as well as of the engine components after a cold start. In order to achieve reduced fuel consumption and exhaust gas emissions with the help of heat management, the design criteria of innovative cooling systems need to be reflected and adapted to future requirements. The use of intelligent components within the cooling system, such as the 'Stand Alone Rotary Valve' as a thermostat's substitute or the use of coolant pumps with a rotary valve integrated into the pump's inlet chamber, offer new ways to realise in a decisively quicker and more flexible way the appropriate heating up and cooling down procedures at varying driving conditions. A description of both of the intelligent ...
1 to the operator of a waste collective system by an agreement or contract. The conditions for the ...Fees of the waste collective system are subject to the supervision of the authority responsible for market surveillance. ...The operator of waste collection system collects wastes from producers and holder and transports these to a collection
Soil gas, soil, and water were assessed for organic and inorganic constituents at the former 19th Street landfill at Fort Gordon, Georgia, from February to September 2010. Passive soil-gas samplers were analyzed to evaluate organic constituents in the hyporheic zone and flood plain of a creek and soil gas within the estimated boundaries of the former landfill. Soil and water samples were analyzed to evaluate inorganic constituents in soil samples, and organic and inorganic constituents in the surface water of a creek adjacent to the landfill, respectively. This assessment was conducted to provide environmental constituent data to Fort Gordon pursuant to requirements of the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. The passive soil-gas samplers deployed in the water-saturated hyporheic zone and flood plain of the creek adjacent to the former landfill indicated the ...
Gene analysis was used to determined the presence, abundance and phylogenetic affiliation of methanogens that exist in gas-hydrate-bearing sediment samples obtained from 23 drill cores from the JAPEX/JNOC/GSC et al. Mallik 5L-38 gas hydrate research well. Rates of methane production were examined using sediment-inoculated enrichments containing {sup 14}C-labeled carbon substrates, carbon dioxide and acetate. Archaeal 16S rDNA was only detected in 6 of the samples, resulting in 8 sequences with relationships to the Miscellaneous Crenarchaeotic Group (7 clones) and the Subsurface Euryarchaeotic Group (1 clone). The single Euryarchaeota sequence did not appear to be related to methanogens. Subsamples from the cores showed variable results upon DNA extraction and amplification. Methanogenic Coenzyme M (CoM) was detected in 13 of the 20 cores, but methanogenic methyl CoM reductase genes were not amplified from the samples when using a sensitive ...
This report describes the design of a well test to determine two-phase hydraulic properties of a low permeability, low porosity formation. Estimation of gas-related parameters in such formations is difficult using standard pumping tests mainly because of the strong fluctuations in the pressure and flow rate data which are a consequence of gas bubbles evolving in the test interval. Even more important is the fact that the data do not allow distinguishing among alternative conceptual models. The estimated parameters are therefore uncertain, highly correlated, and ambiguous. In this study we examine a test sequence that could be appended to a standard hydraulic testing program. It is shown that performing a series of water and gas injection tests significantly reduces parameter correlations, thus decreasing the estimation error. Moreover, the extended test sequence makes possible the identification of the model that describes ...
The industrial standard process for the purification of natural gas is to remove acid gases, mainly hydrogen sulfide and carbon dioxide, by the absorption and reaction of these gases with alkanolamines. Inadequate data for vapor -- liquid equilibrium (VLE) hinder the industry from converting operations to more energy efficient amine mixtures and conserving energy. Some energy reductions have been realized in the past decade by applying such amine systems as ``hindered`` amines, methyldiethanolamine (MDEA), and MDEA based amine mixtures. However, the lack of reliable and accurate fundamental VLE data impedes the commercial application of these more efficient alkanolamine systems. The first project objective is to improve the accuracy of vapor -- liquid equilibrium measurements at low hydrogen sulfide concentrations. The second project objective is to measure the VLE for amine mixtures. By improving the accuracy of the VLE measurements on MDEA and mixtures with other ...
The industrial standard process for the purification of natural gas is to remove acid gases, mainly hydrogen sulfide and carbon dioxide, by the absorption and reaction of these gases with alkanolamines. Inadequate data for vapor -- liquid equilibrium (VLE) hinder the industry from converting operations to more energy efficient amine mixtures and conserving energy. Some energy reductions have been realized in the past decade by applying such amine systems as hindered'' amines, methyldiethanolamine (MDEA), and MDEA based amine mixtures. However, the lack of reliable and accurate fundamental VLE data impedes the commercial application of these more efficient alkanolamine systems. The first project objective is to improve the accuracy of vapor -- liquid equilibrium measurements at low hydrogen sulfide concentrations. The second project objective is to measure the VLE for amine mixtures. By improving the accuracy of the VLE measurements on MDEA and ...
The Coal Quality Engineering Analysis (CQEA) program developed by the New York State Electric and Gas Company (NYSEC) calculates the as-burned cost of burning a specific coal in a specific generation unit. These costs include: maintenance costs for coal and ash handling equipment; ash disposal costs; cost of oil (if required for flame stability and/or derating because of pulverizer capacity limitation); flue gas desulfurization costs; cost of replacement power caused by pulverizer, precipitator fly ash collection and bottom ash capacity limitation; boiler losses due to moisture, hydrogen, dry gas and unburned carbon; power for coal and ash handling equipment; power for coal pulverizers; cost of using excess air to prevent slagging of coal with low ash softening temperatures; and effect of heat rate on coal tonnage required for a desired generation. The use of CQEA to identify areas in which plant ...
This paper constructs an analytic framework for calculating the assembly of galactic disks from the collapse of gas within dark matter halos, with the goal of determining the surface density profiles. Gas parcels (baryons) fall through the potentials of dark matter halos on nearly ballistic, zero energy orbits and collect in a rotating disk. The dark matter halos have a nearly universal form, as determined previously through numerical simulations. The calculation is first carried out for a variety of pre-collapse mass distributions and rotation profiles, including polytropic spheres in hydrostatic equilibrium with the halo potential. The resulting disk surface density profiles have nearly power-law forms, with well-defined edges. This idealized scenario is generalized to include non-spherical starting states and multiple accretion events (due to gas being added to the halo via merger events). This ...
This dissertation describes a measurement of the rate ofnuclear muon capture by the proton, performed by the MuCap Collaborationusing a new technique based on a time projection chamber operating inultraclean, deuterium-depleted hydrogen gas at room temperature and 1 MPapressure. The hydrogen target's low gas density of 1 percent compared toliquid hydrogen is key to avoiding uncertainties that arise from theformation of muonic molecules. The capture rate was obtained from thedifference between the mu- disappearance rate in hydrogen--as determinedfrom data collected in the experiment's first physics run in fall2004--and the world averagefor the mu+ decay rate. After combining theresults of my analysis with the results from another independent analysisof the 2004 data, the muon capture rate from the hyperfine singlet groundstate of the mu-p atom is found to be Lambda_S = 725.0 +- 17.4 1/s, fromwhich the ...
Spontaneous pneumothoraces are believed to arise when air from the supplying airway exit via a ruptured visceral pleural bleb into the pleural cavity. Endobronchial one-way valves (EBVs) allow air exit...Full Text Available
This paper deals with the control of an electromechanical valves engine. The control uses neural networks in order to build a non-linear model of engine filing which depends on the driven inlets. The aim is to build this real-time model and to integrate this model to a control system which performs an iterative inversion. (J.S.)
The phenomenological description of the giant magnetoresistance effect as well as discussion of the requirements which must be fulfilled in giant magnetoresistance thin film structures are given in the first part of our review. In the second part the magnetization reversal and giant magnetoresistance effect of antiferromagnetically coupled multilayers, spin Valve and pseudo-spin valve thin film structures are explained. For these structures we also discuss the influence of the structure defects such as surface roughness and pinholes on the giant magnetoresistance effect. (author)
Purpose: To improve the reliability of control rod drive mechanisms for use in BWR type reactors by preventing erroneous insertion of control rods caused by the increase in the coolant pressure. Constitution: A pressure-releaf valve mechanism is provided which opens its valve when a detected difference between the pressure of the coolants flowing through coolant pipeways and the reactor pressure exceeds a predetermined pressure difference. If the coolant pressure increases abnormally, coolants in the coolant pipeway are released to lower the pressure. (Aizawa, K.).
Eleven patients who had undergone cardiac surgery were studied by means of high-field MR imaging (1.5 T). Six patients had aortic root and valve replaced with a Bjork-Shiley (BS) composite tubular aortic graft prosthesis for acute dissection of ascending aorta. In the other 5 patients with rheumatic calcific aortic disease, the valve had been replaced with a BS prosthesis. As a whole, MR studies were 14. Previous evaluations of magnetic field effects had seem carried out ex vivo on both BS valves and BS composite prostheses, on surgical ligation clips (Tantalium and Stainless) and on stainless wires for sternal closure. In 4 patients (2 BS composite grafts, and 2 BS valves) MRI diagnosed chronic dissection of both arch and descending aorta. In 1 of them, with a bs valve, associated localized acute dissection of ascending aorta was observed. In 3 patients with BS composite grafts, ...
AimsTwo-dimensional echocardiographic (2DE) continuity-equation derived aortic valve area (AVA) in aortic stenosis (AS) relies on non-simultaneous measurement of left ventricular...Full Text Available
The purpose of this report is to determine if it is feasible to utilize the hot exhaust gas discharged from gas turbines in direct applications. This report illustrates the technical feasibility and economic viability of using gas turbines in drying applications. The size of turbines in this investigation ranges from 2 MW to 10 MW. In addition, an implementation strategy has been developed to employ this new system. The method used to structure the scope of this undertaking is as follows: Step 1. Collecting information by contacting dryer manufacturer and companies drying different products. Information was also gathered by literature studies and the internet. Thomas register is a great tool when it comes to company and market searches. Step 2. Looking into if it is technically possible to use the exhaust gas directly into dryers. The parameters needed for these calculations were ...
In General Electric's design of the Simplified Boiling Water Reactor (SBWR), The depressurization valves (DPV) are installed in the reactor pressure boundary: four are connected to the reactor vessel by means of nozzles, and two more are located on the main steam pipes (one DPV for each line), which act during particular transients and/or loss of coolant accidents (LOCA), consequently providing the reactor vessel with a safe quick depressurization system. Once the vessel is de pressurised, the passive gravity-driven cooling system (GDCS) starts to operate, permitting the injection of water required for continuous core cooling. DPVs are leak tight, with welded flaps, actuated by a [striker[hammer***] which is activated by an explosive mixture. The dynamic loads that open these valves include, in addition to those produced by steam (typical in any thermodynamic transient with open/close valves), other important loads that are ...
A study on development of magnetic drive packless valves for commercial purpose showed the results as follows; 1. Study on the radial rays effecting to the permanent magnets -Measurement of the strength of Nd-magnets according to irradiation of radial rays. 2. Effects of temperature on the magnetic driving device -Temperature dependency of the Nd-casting magnets. -Effects of temperature on the heat releasing fins of high-temperature valve. 3. Optimization of torque -Arranging method of permanent magnets -Measuring method and results of torque. 4. Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Calculation and design for the flat circular plates under pressure of the magnetic power transmitting device -Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Comparison of the characteristics between magnetic drive valve ...
Complex abdominal lesions include a variety of pathologies, such as septated, infected, and hemorrhagic cysts, abscesses, tumors, and fluid collections of different ethiology. These lesions present diagnostic difficulties with both Ultrasonography (US) and Computed Tomography (CT), since findings may not be present or, when present, are not specific. Keeping these limitations in mind, we evaluated 105 patients (111 abdominal lesions) with both US and CT in order to compare their adequacy in predicting the nature of the lesion. On the basis of US and CT results, complex abdominal lesions were divided in four classes: class I includes 43 cases in which both examinations gave the same contribution to the definition of the nature of the lesion, class II (14 lesions, mainly sperimentated cysts), in which US was superior to CT, class III includes 45 cases of hemorrhagic cysts, abscesses, fluid collections and, less frequently, cystic tumors; class IV ...
Tarapur Atomic Power Station Unit-3 and 4 (TAPS -3 and 4) are the 540 MWe reactors. Unit-4 attained first criticality on 06th March 2005 and operated for about 230 effective full power days (EFPD). Unit-3 attained first criticality on 21st May 2006 and operated for about 20 EFPD. With the reactor operation radiation field increases on the Primary Heat Transport system equipments, Moderator system equipments and auxiliary system equipments due to deposition of fission products and activation products in different reactor systems. These dose rates significantly contributes to the external exposure and stations collective dose during reactor operation, refueling operation and maintenance activities. A study was undertaken at TAPS 3 and 4 to identify the system equipments showing the significant dose rates and identify the radionuclides present in the primary heat transport system, Moderator systems, cover gas system and other auxiliary system for ...
This report covers the technical effort through February, 1989. This effort was directed towards the technology associated with the development of a large scale, long pulse DF-CO{sub 2} chemical laser. Optics damage studies performed under Task 1 assessed damage thresholds for diamond-turned salt windows. Task 2 is a multi-faceted task involving the use of PHOCL-50 for laser gain measurements, LTI experiments, and detector testing by LANL personnel. To support these latter tests, PHOCL-50 was upgraded with Boeing funding to incorporate a full aperture outcoupler that increased its energy output by over a factor of 3, to a full kilojoule. The PHOCL-50 carbon block calorimeter was also recalibrated and compared with the LANL Scientech meter. Cloud clearing studies under Task 3 initially concentrated on delivering a Boeing built Cloud Simulation Facility to LANL, and currently involves design of a Cold Cloud Simulation Facility. A Boeing IRAD funded theoretical study on cold cloud ...
The significant design features of a high-voltage dc (HVDC) circuit breaker based on the commutation concept were developed. Tests of components indicate the breaker is capable of interrupting a fault current of 10 kA on a 400 kV system and absorbing up to 10 MJ of system energy without generating more than 1.6 per unit (P.U.) voltage of the system. Interactions of the breaker with a three-terminal network were studied, using a system simulator. An ultrafast hydraulic actuator system was developed for this program which enables the breaker to initiate the current limiting process within 5 ms after receipt of a trip signal. A new hydraulic valve, operated by a repulsion coil, minimizes the delay before motion begins. Interruption will occur in series-connected vacuum interrupters. A 400 kV circuit breaker is estimated to require eight breaks in series. Only a single break was tested as part of this program because of the scale and cost required for multibreak tests. ...
Oregon State University (OSU) and the Pacific Northwest National Laboratory (PNNL) were funded by the U.S. Department of Energy to conduct research focused on resolving the key technical issues that limited the deployment of efficient and extremely compact microtechnology based heat actuated absorption heat pumps and gas absorbers. Success in demonstrating these technologies will reduce the main barriers to the deployment of a technology that can significantly reduce energy consumption in the building, automotive and industrial sectors while providing a technology that can improve our ability to sequester CO{sub 2}. The proposed research cost $939,477. $539,477 of the proposed amount funded research conducted at OSU while the balance ($400,000) was used at PNNL. The project lasted 42 months and started in April 2001. Recent developments at the Pacific Northwest National Laboratory and Oregon State University suggest that the performance of absorption and desorption ...
The ''Enabling & Information Technology To Increase RAM for Advanced Powerplants'' program, by DOE request, was re-directed, de-scoped to two tasks, shortened to a 2-year period of performance, and refocused to develop, validate and accelerate the commercial use of enabling materials technologies and sensors for coal/IGCC powerplants. The new program was re-titled ''Enabling Technology for Monitoring & Predicting Gas Turbine Health & Performance in IGCC Powerplants''. This final report summarizes the work accomplished from March 1, 2003 to March 31, 2004 on the four original tasks, and the work accomplished from April 1, 2004 to July 30, 2005 on the two re-directed tasks. The program Tasks are summarized below: Task 1--IGCC Environmental Impact on high Temperature Materials: The first task was refocused to address IGCC environmental impacts on high temperature materials used in ...
The primary goal of this project is to increase the availability and ease of access to critical data on the Mesaverde and Dakota tight gas reservoirs of the San Juan Basin. Secondary goals include tuning well log interpretations through integration of core, water chemistry and production analysis data to help identify bypassed pay zones; increased knowledge of permeability ratios and how they affect well drainage and thus infill drilling plans; improved time-depth correlations through regional mapping of sonic logs; and improved understanding of the variability of formation waters within the basin through spatial analysis of water chemistry data. The project will collect, integrate, and analyze a variety of petrophysical and well data concerning the Mesaverde and Dakota reservoirs of the San Juan Basin, with particular emphasis on data available in the areas defined as tight gas areas for purpose of FERC. A relational, ...
The aim of this paper is to investigate the fluid dynamic behaviour of a commercial hydraulic proportional valve in order to evaluate and justify its global performances and, in particular, to analyze the effects of some additional design features on the reduction of the force required to maintain the valve open. The proposed analysis has been performed by applying the commercial computational fluid dynamics (CFD) code, Fluent, to the solution of the three dimensional turbulent flow field through a circumferential sector of the entire valve for different spool strokes. The reliability of the employed modelization is demonstrated by the comparison between the computed flow rate curve and the corresponding experimental data provided by the manufacturer. With regard to the metering edge design, it is shown that the cylindrical hole provided on the top of the hemi-spherical notch to improve metering at small ...
The paper gives an introduction to reliability assessment of reliquefaction systems for boil-off gas (BOG) on LNG carriers with focus on redundancy optimization and maintenance strategies. The reliability modeling is based on a time-dependent Markov approach. Four different system options are studied, with varying degree of redundancy. Failures in the reliquefaction system may require flaring of the BOG, and the associated cost is compared with the cost of introducing redundancy and the cost of onboard maintenance. A model for maintenance optimization is developed and exemplified on a main unit of the reliquefaction system. Reliability and maintenance cost data for reliquefaction systems on LNG ships are very scarce. The input data have been collected from the best available data sources and adjusted by expert judgement. A tailor-made computer program has been developed and may be supplied to interested readers.
The Fast Flux Test Facility has been in operation for approximately five years, including about one thousand days of full power operation of the Fast Test Reactor. During that time the collective dose equivalents received by operating personnel have been about two orders of magnitude lower than those typically received at commercial light water reactors. No major contamination problems have been encountered in operating and maintaining the plant, and release of radioactive gas to the environment has been minimal and well below acceptable limits. All shields have performed satisfactorily. Experience to date indicates an apparent radiological superiority of liquid metal reactor systems over current light water plants.
Abstract The importance of evaluating greenhouse gas (GHG) emissions from dairy cows within the whole farm setting is being realized as more important than evaluating these emissions in isolation. Current whole farm models aimed at evaluating GHG emissions make use of simple regression equations to predict enteric methane (CH4) production. The objective of the current paper is to evaluate the performance of nine CH4 prediction equations that are currently being used in whole farm GHG models. Data used to evaluate the prediction equations came from a collection of individual (IND) and treatment averaged (TRT) data. Equations were compared based on mean square prediction error (MSPE) and concordance correlation coefficient (CCC) analysis. In general, predictions were poor, with root MSPE (as...
Considerable effort worldwide has been put into trying to find the best way to utilise the large amount of energy that we put into our dustbins every day. One of the problems encountered is that the waste collection systems tend to gather together in one place between 400 and 1000 t of the stuff everyday and since it is possible to extract rather more than 2 MW from each tonne, that is a lot of energy for which to find a market. In continental European cities, especially Germany, and Sweden with most of the population living in apartment blocks, and with colder winters than the UK, district heating provides a suitable market. With its milder winters, more diverse housing and cheap gas the UK is not such a fertile ground for district heating. But since the passing of the Energy Act in 1984, there is a steady market in electricity generation with the advantage that the purchase tariffs are published so that income can be accurately calculated.
A highly effective and economical apparatus was developed by the All-Union Scientific Research Institute for Energy and Nonferrous Metallurgy for cleaning waste gases from cupola and electric arc steel melting furnaces --- the ''Ural'' rotoclone, which has been successfully introduced in many enterprises. Research results are presented for the efficiency of operation of these aggregates on equipping them on cupola and electric furnaces. With a 2 kPa aerodynamic resistance of the rotoclone the flue gas of the cupola furnace is cleaned to the sanitary standard. Highly effective collection of sublimates and aerosols from the electric arc furnace takes place with a ''Ural'' rotoclone aerodynamic resistance
The alloy type 'alloy 800' with its different variants is used for numerous components in high-temperature reactor (HTR) plants, e.g. for hot-gas conductors, the high-pressure part of steam generators, superheaters, steam collecting vessels and live steam conductors. This study deals with the evaluation of creep rupture tests on 28 welded joints of alloy 800 with an accumulated test duration of 410 years, with the objective to obtain quantitative information on a possible loss of strength in comparison with the unwelded material. The longest test period of an individual test amounted to 98,000 h and the analyzed test temperature range lay between 550"0 and 1000"0C. (orig./MM).
The United States Department of Energy (DOE) at the Morgantown Energy Technology Center (METC) contracted with P.S. Lowell and Co. Inc. (Lowell and Co.) and Jay S. Dweck, Consultant, Inc., (JSD) to enhance the capability of ASPEN in simulating coal gasification and oil shale processing plants. Of particular concern was the capability to predict the distribution of environmentally significant components among the various aqueous and organic liquids and gas streams within or leaving the process. The project was divided into major task areas. The first was to develop and implement the calculational routines necessary for predicting aqueous electrolyte chemical reactions. Part of this effort also was to select a species list and collect and/or regress data for the necessary parameters. The second task was to develop and implement a multi-phase flash capability (including precipitated solids) and unit operations models for a venturi and a ...
In a shipping terminal, the pipeline in the pier usually has a diameter smaller than the main pipeline diameter. This diameter reduction amplifies the effects caused by hydraulic transients. It was noticed during simulations that check valves placed in the pier may introduce some error in the maximum pressure when it was modeled in a conventional fashion. The dynamic check valve model had been added to a commercial pipeline simulation software and the results was compared with a similar model using the method of characteristics. Considering a real state shipping terminal case, it was proved even a pipeline that works with low pressure and smooth elevation profile needs a detailed valve modeling to prevent the calculation of unreal pressure values in the region with diameter reduction. (author)
Purpose: To eliminate the water level deviation due to the recycling flowrate, as well as enable a stable control to a reference value even upon changes in the recycling flowrate caused by the variation in the opening degree of a minimum flow valve. Constitution: Reactor recycling system comprises a feedwater pump, a flowrate control valve, a reactor water level detector, and a minimum flow line and a minimum flow valve for preventing the overheating of the feedwater pump at a low flowrate. A flowrate compensator is further disposed, in which a recycling flowrate signal is subtracted from a pump flow rate signal and the result is fedback as a compensated pump flowrate signal. This enables the control system to operate at a rapid response for suppressing the effect of the recycling flowrate as external disturbance, whereby the water level in the reactor can be controlled stably to the reference level and the possibility ...
Purpose: To stably control the reactor water level so as not to cause excess water feeding in a BWR type reactor. Constitution: A flow control valve is disposed to the exit of a feedwater pump for a nuclear reactor and the valve is controlled by a flow regulator to maintain the water level constant in the reactor. A signal from a water level controller is inputted to the flow regulator to thereby control the flow rate control valve. In this case, the flow regulator remains in a saturated state just after the starting of the feedwater pump, in which the pump flowrate is at 100% to result in an excess water feeding condition. In view of the above, a feedback circuit is provided to the flow regulator so that the saturated state is eliminated and the water feeding can be controlled directly from the water level controller. (Kamimura, M.).
A cross-flow atmospheric plasma jet with distilled water or analyte solution nebulization has been investigated. The plasma gas flows perpendicularly to the RF powered electrode (11.21 MHz) and a grounded electrode was added for plasma stabilization. The working parameters of the plasma generator can be controlled in order to maximize either the plasma power (75 W) or the voltage on the RF powered electrode (plasma power, 40 W). The plasma gas, pure argon (0.4 l min-1) or a mixture of argon (0.3-0.4 l min-1) and helium (0-0.2 l min-1), was also used for liquid nebulization. Optical emission of the plasma, collected in the normal viewing mode, was used for plasma diagnostics and for evaluating its excitation capabilities. The influence of helium content in the mixed-gas plasma on the plasma characteristics and on the emission axial profiles of the plasma gas constituents and of the ...
`De Groote Wielen` is going to be a newly built area of the municipality Den Bosch, Netherlands. In the period 1998-2011 circa 6,200 houses and 39,000 m{sup 2} will be built. Under the authority of the municipality Den Bosch CE compared a few energy supply options. Attention is paid to three different forms of energy supply: traditional supply of natural gas and electricity, supply of heat (produced by cogeneration gas engines and collective electrical heat pumps) and electricity, and supply of electricity by means of individual heat pumps for each house. Two levels of the energy performance standard are taken into account: 1.2 and 1.0. Also costs and resulting emissions of those options are compared. Next to a quantitative discussion, also the qualitative consequences of the three concepts are dealt with. The most important quantitative consequence concerns the flexibility of the energy supply for the future, in particular ...
The origin of life and the origin of the universe represent two of the most important problems of science. Both are resolved by hydro-gravitational dynamics (HGD) cosmology (Gibson 1996, Schild 1996, Gibson 2009ab), which predicts frozen primordial hydrogen-helium gas planets in clumps as the dark matter of galaxies. Merging Earth-mass planets formed stars, moons and comets to incubate and cosmically seed the first life. Cometary panspermia (Hoyle and Wickramasinghe 1981, 1982; Wickramasinghe et al. 2009) occurs naturally by HGD mechanisms. Comets and moons are fragments from mergers of stardust covered frozen gas planets in their step-wise growth to star mass. Supernovae from stellar over-accretion of planets produce stardust (C, N, O, P etc.) chemical fertilizer. Planets collect this infected radioactive dust gravitationally, to provide liquid water domains in contact with life nutrients seeded with life prototypes. The ...
This paper presents a nonlinear Bayesian regression algorithm for the purpose of detecting and estimating gas plume content from hyper-spectral data. Remote sensing data, by its very nature, is collected under less controlled conditions than laboratory data. As a result, the physics-based model that is used to describe the relationship between the observed remotesensing spectra, and the terrestrial (or atmospheric) parameters that we desire to estimate, is typically littered with many unknown "nuisance" parameters (parameters that we are not interested in estimating, but also appear in the model). Bayesian methods are well-suited for this context as they automatically incorporate the uncertainties associated with all nuisance parameters into the error estimates of the parameters of interest. The nonlinear Bayesian regression methodology is illustrated on realistic simulated data from a three-layer model for longwave infrared (LWIR) measurements ...
Disposal of fine-particled byproducts via injection into a capola furnace using natural gas/O{sub 2} burners is a cost-efficient alternative to landfill dumping. Tests conducted in a foundry demonstrated that dusts collected there can be injected without detriment to melt-down rate and iron quality. The replacement of FeSi pellets with FeSi dust in addition reduced the slag content, while injection of coal dust permitted a decrease in coke consumption. (orig.) [Deutsch] Die Entsorgung von feinkoernigen Reststoffen durch Einblasen in einen Kupolofen ueber Erdgas/O{sub 2}-Brenner ist eine wirtschaftliche Alternative zur Deponierung. Anhand von Versuchen in einer Giesserei konnte aufgezeigt werden, dass hier anfallende Staeube ohne nachteilige Auswirkungen auf Schmelzleistung und Eisenqualitaet einzublasen sind. Die Substitution von FeSi-Formlingen durch FeSi-Staub brachte zudem eine Reduzierung des Schlackeanteils und das Einblasen von ...
The severe health and environmental hazards posed by inadequate waste-collection systems in the rapidly growing cities of the Third World have stimulated interest in the waste-to-energy options developed in industrialized countries over the past 20 years. This economic study, the first of its kind, provides: (1) a comparative analysis of the characteristics of urban solid wastes in the United States, Europe, and developing countries; (2) basic information on the characteristics and operation of the two main types of waste-to-energy systems used in the developed world - landfill gas (LFG) systems and waste combustion systems; and (3) a preliminary assessment of the feasibility of using these systems in developing countries. The main conclusion is that present technology for the recovery and utilization of LFG appears to be suitable for developing country use, although the design of LFG projects would have to be modified to accommodate higher ...
The automotive paints could be generally differentiated by color, layer sequence and chemistry of the paint layers comprising each of the topcoat and the primer system. The successful identification of hit-and-run a and traffic accidental vehicles from evidential paint fragments is greatly facilitated with a comprehensive laboratory collection of reference paint samples and the technique for direct analysis without sample preparation. The Pyrolysis-Gas Chromatography(PGC) is a precise and reliable method for performing both quantitative and qualitative analysis of polymeric materials and forensic samples. Our Forensic Laboratory is conducting the examination and identification of 73 reference paint samples; 4 colors of each domestic automotive make that is poplar in Korea, by Curie Point Pyrolyzer(JHP-3) and GC with capillary column(ultra alloy-5). This method can be used not only to compare paint traces with their suspected sources, but also ...
A safety analysis code to design a pressurized water reactor and to obtain the licences including entire proprietary rights is under development in domestic research and development project. The purpose and scope of this report is to develop the flow regimes related models for inter-phase friction, wall frictions, wall heat transfer, and inter-phase heat and mass transfer in two-phase three-field equations. In order to choose choose the flow regime criteria, we have investigated various exiting best-estimate T/H codes in this chapter 2. They are the RELAP5-3D, TRAC-M, CATHARE, MARS codes. Around 500 references used in these codes have been collected and reviewed. Also we have investigated eleven papers in detail. In chapter 3, based on the selected flow regimes, the flow regime maps for a gas-liquid flow in horizontal and vertical tubes have decided including the mechanisms of flow regime transition regions. Conclusively, the process will be ...
Featured Collections Featured collections are information sources that use federated search or are known for presenting exceptional, authoritative information for...
Field data for validating plume models were collected in and around the Bull Run Steam Plant during two four-week periods between July and October, 1982. The field measurements were the second phase of the Plume Model Validation and Development (PMV and D) program. The Bull Run Steam Plant is located near Oak Ridge, Tennessee, and the area is described as the ''Moderately Complex Site'' to distinguish it from the ''Plains Site'' in eastern Illinois, which was the scene of the first phase of the PMV and D study conducted in 1980-81. The measurement program consisted of a set of meteorological, source, aerometric, and tracer measurements to track and characterize the plume. The tracer measurements constituted the largest portion of the total effort, and it involved the release of SF/sub 6/ tracer gas from the stack, and the sampling and analysis of nearly 64,000 air samples ...
Twenty-four male weanling rats were fed either copper-adequate or -deficient diets until 9 or 11 weeks of age. Deficient rat hearts had increased mitochondria: myofibril compared to adequate rats. Eleven week old deficient rat hearts had decreased mitochondria: myofibril as the hearts increased in weight, but the larger hearts had greater myofibril volume densities. Cardiac mitochondria of deficient rats appeared vacuolated with fragmented cristae and translucent matrix. Valves from copper deficient rats appeared to have less connective tissue and were fragmented in areas. For deficient rats, heart:body weights of 9 wk old rats were negatively correlated with bicuspid valve pathology scores, whereas tricuspid valve scores from 11 wk old rats were negatively correlated with myofibril volume densities. These data suggest that the enlargement of the copper-deficient rat heart is due to: larger (1) mitochondria and (2) ...
The contribution of platelets and clotting factors in thrombosis on cardiovascular prostheses had been quantified with several tracers. Thrombus formation in vivo could be measured semiquantitatively in animal models and patients with indium-111, Technetium-99m labeled platelets, iodine-123, iodine-131 labeled fibrinogen, and In-111 and Tc-99m labeled antibody to the fibrinogen-receptor on the platelet- membrane, or fibrin. The early studies demonstrated that certain platelet-inhibitors, e.g. sulfinpyrazone, aspirin or aspirin- persantine increased platelet survival time with mechanical valves implanted in the baboon model and patients. Thrombus localization by imaging is possible for large thrombus on thrombogenic surface of prosthesis in the acute phase. The majority of thrombus was found in the sewing ring (Dacron) in the acute phase in both the mechanical and tissue valves. The amount of retained thrombus in both mechanical and tissue ...
BackgroundThoracic injuries play an important role in major trauma patients due to their high incidence and critical relevance. A serious consequence of thoracic trauma is pneumothorax,...Full Text Available
This paper reviews 165 cases of lower urinary obstruction in infancy. The commonest lesions were posterior urethral valves (91) and ectopic ureterocele (34), stenosis or atresia of the urethra (8),...Full Text Available
This paper describes the advent of energy pumped storage plants in France, in connection with nuclear power reactors development and gives detailed specifications of different components (pump turbines, alternators, valves ...). 5 figs., 3 tabs.
Libman-Sacks endocarditis is a well-known and rather common cardiac manifestation of systemic lupus erythematosus. Transesophageal and transthoracic echocardiography are the definitive imaging methods...Full Text Available
This report deals with the establishment of durability and reliability for the new type decompression brake system for large diesel engines. By testing engines on the bench, it has been found that the cylinder pressure, with the cylinder at the compression stroke upper dead center, imposed on the exhaust valve bevel section during brake operation constitutes the maximum load on the valve train system, that the cylinder pressure, with the cylinder at the compression stroke upper dead center, rises in proportion to a rise in the engine rpm, and that the load on the valve train system is at its maximum when the exhaust valve opens by brake operation. By examining the conditions whereunder a real vehicle was allowed to run, it has been found that the brake is applied approximately four times more often when the vehicle runs in a city area than on an expressway and that when running on the expressway the ...
BackgroundLung volume reduction surgery is effective at improving lung function, quality of life, and mortality in carefully selected individuals with advanced emphysema. Recently,...Full Text Available
Results are presented of analysis of the dust content of air and the resources for removing sludge at the mines of the Kuzbass during drilling of ascending shafts. A design is proposed for sludge removing devices with automatic opening and closing of the valve hinges.
We report a case of chylopericardium after ascending aorta and aortic valve replacement, which presented as late tamponade. We discuss the various treatment options in this rare condition which can...Full Text Available
This article introduces a predictive capability for Hg retention in any Ca-based wet flue gas desulfurization (FGD) scrubber, given mercury (Hg) speciation at the FGD inlet, the flue gas composition, and the sulphur dioxide (SO2) capture efficiency. A preliminary statistical analysis of data from 17 full-scale wet FGDs connects flue gas compositions, the extents of Hg oxidation at FGD inlets, and Hg retention efficiencies. These connections clearly signal that solution chemistry within the FGD determines Hg retention. A more thorough analysis based on thermochemical equilibrium yields highly accurate predictions for total Hg retention with no parameter adjustments. For the most reliable data, the predictions were within measurement uncertainties for both limestone and Mg/lime systems operating in both forced and natural oxidation mode. With the U.S. Environmental Protection Agency's (EPA) Information ...
To use such sites very effectively, pile foundations will be used for soil stabilization and for important structures for the prevention of subsidence. Negative friction that may ensue from the differential settlement of the soil has to be prevented. Measures against gas will include gascollecting and exhausting facilities in the lower parts of structures, natural and forced exhaust systems, and gas detection/warning units. For revegetation, plants strong against bad soil should be selected, they should be protected from generated gas with protecting sheets or the like, and a thick layer of vegetation-capable soil needs to be laid. Replacement, compaction, and solidification are the fundamentals of soil improvement at wastes final treatment locations and of soil-related pollution prevention in the vicinity of the newly produced sites. Across the country, the service life expectancy ...
The Ordos Basin, the second largest sedimentary basin in China, contains the broad distribution of natural gas types. So far, several giant gas fields have been discovered in the Upper and Lower Paleozoic in this basin, each having over 1000x10{sup 8}m{sup 3} of proven gas reserves, and several gas pools have also been discovered in the Mesozoic. This paper collected the data of natural gases and elucidated the geochemical characteristics of gases from different reservoirs, and then discussed their origin. For hydrocarbons preserved in the Upper Paleozoic, the elevated {delta}{sup 13}C values of methane, ethane and propane indicate that the gases would be mainly coal-formed gases; the singular reversal in the stable carbon isotopes of gaseous alkanes suggests the mixed gases from humic sources with different maturity. In the Lower Paleozoic, the {delta} {sup 13}C{sub 1} values are ...
Full text: Magnetic multilayer materials are becoming technologically important as they provide a more efficient means of magnetic reading and storage through utilisation of their giant magnetoresistance and oscillatory magnetic coupling. This study presents preliminary tight-binding calculations with a view of developing a consistent tight-binding model of `spin valve` Fe-Cu-Fe tri-layer materials. Further work involves using a self-consistent tight-binding approach to obtain a more accurate picture of this system and a better understanding of surface effects at the Fe-Cu interface 1 fig., 4 refs.
Requirements are provided for NSLS beam line front ends and vacuum interlocks. Guidelines are provided for UHV beam line vacuum systems, including materials, vacuum hardware (pumps, valves, and flanges), acoustic delay lines and beam line fast valves, instrumentation, fabrication and testing, and the NSLS cleaning facility. Also discussed are the design review for experimenters' equipment that would be connected to the NSLS and acceptance tests for any beam line to be connected with the ring vacuum. Also appended are a description of the acoustic delay line as well as the NSLS vacuum standards and NSLS procedures. (LEW)
Westinghouse Electric Germany GmbH has developed fluid dynamic models for medium-actuated armatures using the thermal hydraulic code RELAP5 in order to reach a more realistic description of the armature behavior including fluid-structure interactions in case of transient flow conditions in piping systems. The contribution is concerned with the modeling of damped check valves. The model allows the description of the behavior during opening and closure of a check armature. The calculated results show good agreement with the available measured data.
The present invention is a device for a solar heating system having a solar collector, a storage tank connected to the solar collector, a pump for circulating liquid from the tank to the solar collector, a supply of liquid at a temperature above freezing and a connection from the supply of liquid to the solar collector for replacing any liquid lost from said solar collector. The device comprises a sensor for sensing the temperature of liquid in the solar collector, and a valve for bleeding liquid from the solar collector when the sensed temperature falls below a predetermined minimum whereby cool liquid in the solar collector is automatically replaced by liquid at a temperature above freezing.
Polychlorinated dibenzo-p-dioxins and dibenzo-furans form a family of more than 200 compounds which are relatively stable in the biosphere and tend to accumulate in the human body. The tetra- to hexa-chlorinated dioxins and furans are considered highly toxic. To facilitate the assessment of the total toxicity of dioxin and furan mixtures, the estimated toxic effects of the individual compounds relative to the 2,3,7,8-tetrachloro-dibenzo-p-dioxin (TCDD) were introduced as Toxic Equivalent Factors which yield, when multiplied with the respective concentrations, the Toxic Equivalent (TE) of the mixture. Toxic dioxins and furans are unintentionally formed in a number of industrial combustion processes such as waste incineration and iron ore sintering, in the chemical industry and in household heating. To keep the emissions as low as possible, off-gas clearing systems for the collection of dioxins and furans are increasingly prescribed by the ...
Explicitly defining virtual collections in a digital library can benefit both users and contributors. This paper outlines the costs and benefits for defining virtual collections and describes an implementation of collection-level metadata in two digital libraries. Our work suggests that component repositories of NSDL would profit by describing their collection, and sub-collections, using a schema such as the one we implemented. This would enable NSDL to provide a rich, cross-linked hierarchy of virtual collections. By sharing collection-level, rather than item-level, metadata, collections would provide detailed resource information, presumably keeping most of their viewership, while NSDL would provide a broad description of resources.
Full text: This presentation will review the progress achieved so far by the Irish national regulatory agency, the Radiological Protection Institut e of Ireland (R.P.I.I.) in the investigation of work activities where the presence of natural radiation sources (NORM) could lead to a significant increase in exposure to workers or members of the public which cannot be disregarded from the radiation protection point of view. Since the coming into force in Ma y 2000 of the Radiological Protection Act, 1991 (Ionising Radiation) Order, 2000 (S.I. No. 125 of 2000) which implements the Eu B.S.S. Directive 96/29/EURATOM, four major NORM industries currently active in Ireland have been investigated. According to the literature, they are all considered liable to involve work practices resulting in exposure to NORM. They include: the gas extraction and production industry, the peat- and coal-firing power generation industry and the bauxite/alumina refining industry. For the ...
In the beginning of 2005 several changes in the electricity and natural gas market law came into effect. This report examines the influence and impact of these changes on the behaviour and development of these markets, looking at the role and position of both the energy industry and customers. The report combines existing data with new research data collected during spring and summer 2006. Whilst the recency of the law changes, along with the simultaneous impact of other market variables limits the salience of any impact, the report nevertheless provides clear and interesting conclusions. In the electricity market, one major legislative change that came into force in the beginning of 2005 concerned the supervision of the reasonableness of electricity distribution pricing. According to the newly adopted ex ante regulation principles, the regulatory authority now determines the guidelines for reasonable pricing prior the start of a predefined ...
This report documents the results of a project funded by DoD's Strategic Environmental Research and Development Program (SERDP) on the science behind development of predictive models for soot emission from gas turbine engines. Measurements of soot formation were performed in laminar flat premixed flames and turbulent non-premixed jet flames at 1 atm pressure and in turbulent liquid spray flames under representative conditions for takeoff in a gas turbine engine. The laminar flames and open jet flames used both ethylene and a prevaporized JP-8 surrogate fuel composed of n-dodecane and m-xylene. The pressurized turbulent jet flame measurements used the JP-8 surrogate fuel and compared its combustion and sooting characteristics to a world-average JP-8 fuel sample. The pressurized jet flame measurements demonstrated that the surrogate was representative of JP-8, with a somewhat higher tendency to soot formation. The premixed flame ...
A spreadsheet-based decision support system has been developed that allows easy evaluation of integrated biomass to electricity and biomass to ethanol systems. The Bioenergy Assessment Model (BEAM) has been developed to allow the techno-economic assessment of biomass to electricity and biomass to ethanol schemes, including investigation of the interfacing issues. Technical and economic parameters can be assessed for a variety of feedstocks, conversion technologies and generating cycles. Production modules are currently available for biomass supply from short rotation coppice and conventional forestry relevant to conditions and practices in NW Europe. The biomass conversion modules include pre-treatment (reception, storage, handling, comminution, screening and drying); atmospheric gasification (generic gasifier, wet gas scrubbing, dual fuel engine); pressure gasification (generic gasifier, hot gas filtration, gas turbine ...
PETROBRAS/TRANSPETRO Pipelines and Terminals have 500 regular employees and 5.064 out sourced workers in its Southeast Division. The out sourced employees work under 125 contracts involving a wide range of activities such as maintenance, pipeline operation, pipeline launching, engineering, administrative and auxiliary services. Among these workers, 1.200 peoples are subjected to occupational exposure, which may be present in the industrial process or in the products transported in our pipelines, e.g. industrial noise, sulfidric gas, toluene, xylene and benzene (recognized as a carcinogen according to ACGIH and Brazilian Ministry of Labour). Our PPRA (acronym in Portuguese for Occupational Exposure Prevention Program) involves the workforce and fosters health by anticipation, recognition, evaluation and control of the situations that may result in injuries. Further actions include the procurement of equipment for detection of these agents not only in the air but ...
Nitrite was measured in atmospheric liquid phase samples between 1998 and 2005 to investigate the heterogeneous formation of nitrous acid in the lower atmosphere, as well as to assess the quality of water recovered from dew. The samples were collected during ground-based cloud field experiments at different German mountain sites (Brocken, Schmucke, and Hohenpeissenberg) and at a site south of the Bordeaux urban area (France). Concentrations found in Bordeaux dew samples (up to 2800 ?gl-1) are comparable to those found elsewhere in urban fog and dew water and considerably higher than those detected in cloud water or rain. Particulate nitrite (and nitrate) as well as HNO2 (HNO3) data in air masses from a foothill site of Mt. Schmucke, before involved in cloud processing, are also presented. In clouds at Mt. Brocken, both the interstitial HNO2 gas and the aqueous phase nitrite concentration have been measured simultaneous. Significant deviations ...
A 72-year-old man was exposed to the sarin gas attack in a Tokyo subway on March 20 th, 1995. After exposure, he noticed eye discomfort, chest tightness, headache and weakness of the lower limbs and oropharyngeal muscles. Despite these symptoms, he visited a hot spring on the same day with his family. On March 25 th, his muscle weakness progressed, and a low grade fever appeared. His muscle weakness disappeared 8 days after exposure to sarin, but respiratory failure rapidly developed, necessitating artificial ventilation within four day after hospitalization on March 28th. Chemotherapy with erythromycin, imipenem/cilastatin, and steroid pulse therapy was begu. PCR and culture of sputum collected by bronchofiberscopy were positive for Legionella pneumophila, serogroup I. His respiratory state improved, but subsequent infection with Pseudomonous aeruginosa. Enterobacter cloacae, and Candida tropicalis/glabrata caused his death 71 days after ...
Worker exposures to N-nitroso compounds were evaluated at B.F. Goodrich Company, Woodburn, Indiana on December 12, 1979. Personal and area air samples were collected and analyzed by gas-chromatography and thermal-energy-analysis methods. All of the samples contained N-nitrosomorpholine (NMOR) and five samples also contained N-nitrosodimethylamine (NDMA). The amount of NMOR ranged from 0.85 to 3.7 micrograms per cubic meter (micrograms/cu m) for area air samples and 0.63 to 1.8 micrograms/cu m for personal samples. NDMA concentrations ranged from undetectable to 1.8 microgram/cu m for area samples and undetectable to 0.09 micrograms/cu m for personal samples. The authors note that no exposure standards exist for NDMA or NMOR but both are listed as potential human carcinogens. They suggest that the B.F. Goodrich Company characterize nitrosamine exposures at this facility.
A methanol car means a car driven with a fuel that has part of or the whole of the gasoline or kerosene replaced with methanol. Fuel methanol is abundantly available, relatively easy to transport and store and has few environmental pollutants in its exhaust gas. Its octane value is high, but ignitionability is not good due to its low cetane value. It is good for Otto cycle engines, but not adequate for diesel cycle engines. As a technological problem, the point is ignitionability and development of Otto type methanol engines ahead of that of diesel type methanol engines. Evaluation of methanol cars is internationally high and its development is done vigorously, but there are also problems including a short continuous travel distance due to the low heating value of methanol. Although methanol cars are deemed to be most promising for commercialization among cars using alternative fuel, it is necessary to cope systematically and collectively in ...
The authors investigate the optimisation of solar-heated cavity receivers in which solar energy collected by a paraboloid collector is converted into electrical energy. The focussed solar energy enters the receiver through an aperture to heat the working fluid, which flows inside the receiver tubes and is compressed by the compressor of a gas turbine system, to the highest process temperature. A method of calculating the distribution on the inner receiver surfaces of the solar radiation reflected by the paraboloid collector is presented to begin with. The interchange of radiant energy inside the receiver cavity can be calculated on this basis, including the radiation loads, the temperatures of the inner receiver walls, and the radiative and convective losses. The temperature fields in the tube walls must be known for determining the strength required of receiver tubes; they can be derived from the useful heat which comprises a directed ...
The fusion materials program has little irradiation effects data at temperatures from 100 to 350 degree C. Near-term machines such as the International Thermonuclear Engineering Reactor (ITER) will expose materials to neutron doses of 38 to 50 dpa at 150 degree C or less. The data base for structural materials must be extended into this range. Also, lower temperatures are needed to investigate the lower bound for tritium release from solid breeder materials. A low temperature test vehicle is proposed for the Fast Flux Test Facility (FFTF), which will provide test temperatures of 100 to 350 degree C. An 8.5-cm dia. by 100-cm test volume will be instrumented to collect temperature data and provide feedback for control. The spectrum and flux will provide accelerated damage accumulation for structural materials testing and the best available approximation of fusion reactor conditions for solid breeder materials testing. Breeder samples can be equipped with sweep ...
The share of peat in the primary energy supply in Finland in 1996 was about 6.5 % and the area used for peat production was about 535 km"2, corresponding to about 0.5 % of the original peatland area of Finland. Fuel peat production is hence a significant form of using natural resources. About 1.4 % of the total peatland area has been reserved for peat production. Approximately 95 % of the peat excavated in Finland is used as fuel peat, and 5 % as horticultural peat. As raw material and fuel peat can be considered to be slowly renewable material. The environmental impacts of fuel peat production, transportation and peat combustion were evaluated in this research by methods used in life-cycle assessment. Preparation and production phases of peat production areas, fuel peat transportation to power plants, combustion of peat in power plants, and disposal of the ashes formed the basis for the investigation. Data collected in 1994-1996 was used as the basic material in ...
This Baseline Risk Assessment report is the second volume in a set of three volumes for operable Unit 1 (OU-1). The companion documents contain the Remedial Investigation and the Feasibility Study. Operable Unit 1 (OU-1) is one of several groups of hazardous waste sites located at Eielson Air Force Base (AFB) near Fairbanks, Alaska. The operable units at Eielson are typically characterized by petroleum, oil, lubricant/solvent contamination, and by the presence of organics floating at the water table. In 1989 and 1990, firms under contract to the Air Force conducted field studies to gather information about the extent of chemical contamination in soil, groundwater, and soil air pore space (soil gas) at the site. This report documents the results of a baseline risk assessment, which uses the 1989 and 1991 site characterization database to quantify the potential human health risk associated with past Base industrial activities in the vicinity of OU-1. Background data ...
The objective of this report was to evaluate four possible alternative methods of preparing and packaging spent fuel assemblies for geologic disposal against the Reference Process of unmodified spent fuel. The four alternative processes were: (1) End fitting removal, (2) Fission gas venting and resealing, (3) Fuel bundle disassembly and close packing of fuel pins, and (4) Fuel shearing and immobilization. Systems analysis was used to develop a basis of comparison of the alternatives. Conceptual processes and facility layouts were devised for each of the alternatives, based on technology deemed feasible for the purpose. Assessments were made of 15 principal attributes from the technical, operational, safety/risk, and economic considerations related to each of the alternatives, including both the surface packaging and underground repository operations. Specific attributes of the alternative processes were evaluated by assigning a number for each that expressed its ...
The thesis deals with methods of describing the reservoir rock in central oil and gas fields on the Norwegian continental shelf. Methods of enhancing the level of recovery are dealt with. Following topics are given: Sand body dimensions and infill sequences of stable, humid-climate delta plain channels; minipermeameter-based study of permeability trends in channel sand bodies; significance of tidal cyclicity for modelling of reservoir heterogeneities in the lower Jurassic Tilje Formation, mid-Norwegian shelf; geometry and facies of large-scale flow units in fluvial-dominated fan-delta-front sequences; quantified fluvial architecture in ephemeral stream deposits of the Esplugafreda Formation (Palaeocene), Tremp-Graus Basin, northern Spain; the Safari project - collection and storage of field analogue data for quantitative reservoir modelling; sedimentary architecture of field analogues for reservoir information (SAFARI): a case study of the ...
Citizens Gas and Coke Utility operates three coke oven batteries, producing both foundry coke and blast furnace coke, under the trade name Indianapolis Coke. Active participation in the regulation negotiation process by the Vice President of Indianapolis Coke allowed the company to accurately anticipate the environmental regulations, long before they were set in law. Several improvements were put into motion that helps them meet the new environmental regulations. Better trained operators with new job positions dedicated solely to environmental compliance, an extensive environmental training program, and two innovations, a portable oven door milling and cleaning machine and three new computer applications are the result of team efforts. The focus of this paper is development of the computer applications designed to enhance three areas of environmental compliance. The three areas addressed by the applications are documentation and information deployment, problem ...
This study examined the atmospheric pollution created by some waste treatment and disposal facilities in the State of Kuwait. Air monitoring was conducted in a municipal wastewater treatment plant, an industrial wastewater treatment plant established in a petroleum refinery, and at a landfill site used for disposal of solid wastes. Such plants were selected as models for waste treatment and disposal facilities in the Arabian Gulf region and elsewhere. Air measurements were made over a period of 6 months and included levels of gaseous emissions as well as concentrations of volatile organic compounds (VOCs). Samples of gas and bioaerosols were collected from ambient air surrounding the treatment facilities. The results obtained from this study have indicated the presence of VOCs and other gaseous pollutants such as methane, ammonia, and hydrogen sulphide in air surrounding the waste treatment and disposal facilities. In some cases the levels ...
... Waste Collection Systems Products and Equipment Find and compare a variety of waste collection systems products and equipment on the world's largest environmental industry portal. View product ...
The particulate matter of a light-duty diesel engine was characterized in its morphology, sizes, internal microstructures, and fractal geometry. A thermophoretic sampling system was employed to collect particulates directly from the exhaust manifold of a 1.7-liter turbocharged common-rail direct-injection diesel engine. The particulate samples collected at various engine-operating conditions were then analyzed by using a high-resolution transmission electron microscope (TEM) and an image processing/data acquisition system. Results showed that mean primary particle diameters (dp), and radii of gyration (Rg), ranged from 19.4 nm to 32.5 nm and 77.4 nm to 134.1 nm, respectively, through the entire engine-operating conditions of 675 rpm (idling) to 4000 rpm and 0% to 100% loads. It was also revealed that the other important parameters sensitive to the particulate formation, such as exhaust-gas recirculation (EGR) rate, ...
A relational database capable of storing and manipulating the large volumes of data on air toxic metals has been developed for the Center for Air Toxic Metals at the Energy and Environmental Research Center (EERC) of the University of North Dakota. The database provides information to researchers, managers, and operations personnel to aid in their decision making and long-term planning of issues related to air toxic metals. A personal computer-based graphical user interface is used to access the data located on a UNIX workstation at the EERC. With security codes and software issued by the EERC and an Internet service provider in place, the database can be accessed externally through the Internet. Currently the database contains over 3000 analytical measurements from nine full-scale systems and several bench-scale operations. Data are available on gas, solid, and liquid stream samples as well as relevant engineering parameters, including process data. Data will be ...
Purpose: To assess the role of CT in the evaluation of traumatic and spontaneous oesophageal perforation. Materials and methods: From March 2001 to May 2003, we studied 12 patients (7 males and 5 females; age range: 25-66 years, mean age: 43.5 years) with suspected oesophageal perforation due to motor-vehicle accidents (4 cases), stab wound (one case), post-intubation (2 cases), foreign body ingestion (2 cases) and spontaneous (3 cases). Five patients underwent standard chest and cervical radiography; two patients with suspected foreign body ingestion also underwent a gastrografin swallow study; all of the 12 patients underwent CT of the neck, chest and abdomen before and after intravenous, and in four cases oral, administration of contrast material. Results: In 5 patients with cervical, thoracic and abdominal trauma, the CT examination showed the presence of pleuroparenchymal injury (pneumothorax, pleural effusion and subcutaneous emphysema) as well as findings suggestive of ...
The invention relates to a method for purifying a gas mixture containing at least one undesirable gas compound utilizing certain sulfonamide or sulfamide solvents.
Nuclear power plant has several safety features and each safety feature is based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear power plant to keep operational readiness of pumps and valves by In-Service Test (IST). According to Ministry of Education, Science and Technology (MEST) Bulletin 2008-14, the safety functioned pumps and valves of all nuclear power plants of Korea Hydro and Nuclear Power Co. Ltd.(KHNP) have been tested to verify their performance of safety function. Each safety grade pump has own design requirement and should be tested to identify whether it could meet the requirement. Design requirements and test references of all safety grade pumps of Wolsung Nuclear Power Plant Unit 2 (Wolsung Unit 2) were examined in this study. And the results of the performance test of the pump were also compared to the design requirements of each pump.
Nuclear power plant has several safety features and each safety feature is based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear power plant to keep operational readiness of pumps and valves by In-Service Test (IST). According to Ministry of Education, Science and Technology (MEST) Bulletin 2008-14, the safety functioned pumps and valves of all nuclear power plants of Korea Hydro and Nuclear Power Co. Ltd.(KHNP) have been tested to verify their performance of safety function. Each safety grade pump has own design requirement and should be tested to identify whether it could meet the requirement. Design requirements and test references of all safety grade pumps of Wolsung Nuclear Power Plant Unit 2 (Wolsung Unit 2) were examined in this study. And the results of the performance test of the pump were also compared to the design requirements of each pump.
On June 19, 1998, after the first annual outage, Wolsung Unit 2 was shutdown at a controlled rate due to the continuous instability of Liquid Zone Control level. Investigation revealed that the Liquid Zone Control level instability was caused by water condensed inside the helium lines, generated from the moistened helium flow, especially, inside the helium balance header feed and bleed valve lines. It was found that improper installation of the diaphragm type isolation valves and the drain valve tap could easily contain the water inside the lines and be destined to form water traps causing the balance header pressure oscillation. After the lines were dried, Liquid Zone Control level instability was almost vanished, and approached the allowable equilibrium state. As the reactor power was increased, however, the zone level instability increased again. In order to compensate for the excessive, the Bulk Power Control Gain (Kp) ...
BWRs are so designed that the exhaust steam from main steam safety relief valves is led to pressure suppression pools, and the steam is condensed in pool water, but at this time, dynamic load seems to arise in the pool water. In Tokai No. 2 Power Station, a Mark-2 containment vessel was adopted to improve the reliability as much as possible and to obtain the design with margin. In this report, the result of actual machine test in Tokai No. 2 Power Station and the method of reducing the load are described. When a relief valve works, the discharge of water in exhaust pipes into a suppression pool, the exhaust of air in exhaust pipes and repeated expansion and contraction of bubbles in pool water, and the exhaust of steam and condensation occur. As for the construction of the suppression pool in Tokai No. 2 Power Station, cross-shaped quencher and the structure with jet deflector were installed. The test plan and the test result with an actual ...
The CATHENA (formerly ATHENA) has been used to simulate the thermalhydraulic behaviour of the WOLSUNG-1 CANDU-600 reactor during the D_20 spill incident of 1984 November 25. A 4-inch (nominal) Liquid Relief Valve inadvertently opened in the reactor auxiliary system during normal reactor operation, resulting in a discharge of heavy water from the primary heat transport system. The valve remained open for approximately 29 minutes. CATHENA is an advanced thermalhydraulic computer code for analysis of postulated loss-of-coolant accidents (LOCA) and transient faults in CANDU nuclear reactors. A full two-fluid (six-equation) representation of the two-phase flow is used. Component models are used to represent pumps, valves, critical discharge, etc., which are necessary to describe the behaviour of the CANDU system under upset conditions. Heat transfer between the fluid and piping walls (or fuel) is modelled using applicable ...
The characteristics of per-fluorocarbon compounds (PFC) are colorless, non-toxic, easily vaporized and nonflammable. Also, some of them are liquids of a high density, low surface tension, low latent heat and low specific heat. These particular chemical and physical properties of fluoro-organic compounds permit their use in very different fields such as electronics, medicine, tribology, nuclear and material science. The Sonatol process was developed under a contract with the DOE. The Sonatol process uses an ultrasonic agitation in a PFC solution that contains a fluorinated surfactant to remove radioactive particles from surfaces. Filtering the suspended particles allows the solutions to be reused indefinitely. They applied the Sonatol process to the decontamination of a heterogeneous legacy Pu-238 waste that exhibited an excessive hydrogen gas generation, which prevents a transportation of such a waste to a Waste Isolation Pilot Plant. Korea Atomic Energy Research ...
Purpose: In vitro evaluation of possible deflection and heating of present-day prosthetic heart valves, 12 technical and 5 biological, were investigated using a 1.5 Tesla Siemens Vision system. Deflection was measured at the edge of a 1.5 Tesla superconducting magnet. Each valve was then submerged in a vial of a 1/1 electrolyte solution and temperature was measured before and after imaging with a turbo-spin-echo sequence (TR 5200 ms, TE 138 ms, Flip angle 180 C, acquisition time 10.5 minutes, length of echo train 29). MR imaging was performed with phase encoding parallel and perpendicular to the plane of the valves. Results: None of the investigated prosthetic heart valves was deflected. The maximal observed temperature rise was 0.5 C. During MR investigation of the prostheses, artifacts caused by metallic parts were less evident using a spin-echo sequence than a gradient-echo sequence. Conclusions: ...
Transcatheter coil embolization for coronary artery to left ventricular fistula was successfully performed in a neonate. At 30 weeks' gestation, fetal echocardiography showed a hypoplastic right ventricle with intact ventricular septum, absent pulmonary valve, tricuspid atresia, and marked distension of the right coronary artery. After birth, the neonate had congestive heart failure and the electrocardiogram showed myocardial ischemic changes in the left ventricular area. Aortography showed a dilated right coronary artery arising from the ascending aorta and draining into the left ventricle. Transcatheter coil embolization was carried out on the 9th day after birth. Since the procedure, no myocardial ischemic changes have been detected. Transcatheter coil embolization is a useful therapy for coronary artery fistula associated with myocardial ischemia. PMID:15564713
For shut-down safety of the turbine generator (securing of auxiliary power operation after load shut-down and preventing the reaching of overspeed after load shut-down with disturbed turbine governing system) additional measures compared to those for superheated steam turbines are required for turbine generators in plants with pressurized water reactor (PWR) as well as those with boiling water reactor (BWR) . Equipment is described (e.g. overspeed govern or selecting connection, vacuum breaker, bypass valves, intercepting valves) which, depending on the own conditions of the individual turbine generator (e.g. run-up time, vacuum, enclosed energy), may be applied alone or in jointly. (orig.).
New standard catalogs for piping, supports, and valves have been introduced by Kraftwerk Union (KWU) for the first time in its Convoy series of PWR plants. These catalogs, underlying regulatory codes, and newly developed KWU specifications are described. Feedwater and main steam piping systems within the containment, including pipe supports and valves, are used to demonstrate the high quality level of piping technology achieved in the Federal Republic of Germany. Such quality standards ensure the integrity of single components as well as of the entire system, so that, under certain conditions, pipe whip restraints against postulated breaks have become unnecessary. The quality aspects apply basically for both PWR and BWR plants of KWU.
Presented in this report are the quantitative and qualitative aspects of the more than 5,800 applications of Grafoil on-plant. The subject all-graphite product was originally made by the Union Carbide Corporation. Its utilization in the forms of valve packing, gasketing and sealant tapes for leak repair and prevention on-plant since March 1970 is marked with typical zero-leak results. For all practical purposes, the successful results with Grafoil implementation indicate an unqualified control of leakage problems that began in 1967 with the V-11 and V-12 valves in the primary system of N Reactor. Meaningfully, the accruals of savings with existing and future applications shall continue to be incalculable in personnel exposure, maintenance, and capital. Inherent in the savings are the devised methodology and innovative developments coordinately employed in resolving the leak repair problems.
The loss of seal of the H9 channel in vacuum, freeing the entire cross section of the front part, leads to a fast leak that progresses rapidly. The effect of depressurizing the reflector can leads to shutdown of the shutdown rod pumps. The source changer associated with the channel fills completely before the valve closes. All of the leak water remains contained within the source changer containment. After the valves open, cooling of the fuel element is handled by natural convection, requiring a reversal of the flow between the plates. This changeover, which takes place at a relatively low pressure level, could lead to local boiling in the fuel element. Consequently, irreversible transformations cannot be excluded as possibilities for the fuel element and even for the control rod. Subsequently, the can is refilled with heavy water with establishment of the usual pressure levels.
The very low-pressure expansion tank of the title invention is connected to the water in the central heating installation via a connecting pipe with a pump and valves on one side, and on the other side the tank is connected via a connecting pipe with valve to the tap water mains, so that the supply of water can be regulated automatically. Within the expansion tank contact with the outside air is not possible because of an air/water separating floater. By means of recording and control (also remote) of the contents of the expansion tank, the installation pressure and the quantity of supplied water from the expansion tank and the tap water mains, failures and water damage are prevented. 4 figs.
In this study, a new type of thin, compact, and light weighed diaphragm micro-pump has been successfully developed to actuate liquid by the vibration of a diaphragm. The micro-diaphragm pump with two valves is fabricated in an aluminum case by using highly accurate CNC machine, and the cross-section dimension is 28?mm??5?mm. Both valves and diaphragm are manufactured from PDMS. The amplitude of vibration by a piezoelectric device produces an oscillating flow and alters the chamber volume by the curvature change of a diaphragm. Several experimental set-ups for performance tests in a single micro-diaphragm pump, isothermal flow open system, and a closed liquid cooling system are designed and implemented. The performance of a one-side actuating micro-diaphragm pump is affected by the design ...
Purpose: To prevent structure material meltdown upon rupture of cooling pipeways in a impurity remover by preventing the coolants from flowing into the vacuum vessel while continuing the supply of coolants to other portions to be cooled. Constitution: Dual cooling pipeway systems are disposed to the neutralizing plates of the impurity remover. A rupture detector (pressure gage) is mounted to each of the cooling pipeways and flow rate control valves to be opened and closed by the signal from the detector are disposed to the upstream and downstream of the cooling pipeway. In this constitution if the cooling pipes should be ruptured, the coolant supply is stopped to the ruptured system in which the flow rate valve is closed by the signal from the rupture detector. However, since the coolant is kept to be supplied to the other system of the cooling pipeways, meltdown of the neutralizing plates can be prevented. (Kamimura, M.).
Fluidic two diode pumps have been developed for moving highly toxic and for radioactive waste liquors about chemical plant. The pumps have a cylinder into which liquor is initially sucked and then expelled. For situations where no maintenance can be carried out the need has arisen for a fluidic alternator to the solenoid ejector system used on top of the pump cylinder to supply an alternating negative/positive air supply. A fluidic air alternator has been constructed by modifying a small vortex amplifier and inserting an ejector opposite to the throat of the outlet diffuser. The vortex valve ejector is described and performance characteristics are presented. Several developments of the V.V.E. for fluidic pumping and other applications are also reported. (author).
We describe a large-scale application of methods for finding plagiarism in research document collections. The methods are applied to a collection of 284,834 documents collected by arXiv.org over a 14 year period, covering a few different research disciplines. The methodology efficiently detects a variety of problematic author behaviors, and heuristics are developed to reduce the number of false positives. The methods are also efficient enough to implement as a real-time submission screen for a collection many times larger.
Researches and production of radio-isotopes, radio-pharmaceuticals and cold kits are carried out in the Radio-isotope Production Facility (RIPF). Four concrete hot cells in Bank-1 are to produce the Ir-192 source for NDT. Eleven lead hot cells in Bank-2 are to produce Ho-166, Cr-51, P-32/33, Tc-99m, Lu-177, Sr-90/Y-90 and W-188/Re-188 for research purpose. Six lead hot cells in Bank-3 are used for the production of I-131 for diagnosis and therapy of cancer in the hospital. A hot cell in Bank-3 is also utilized for the research of I-125 and Br-82. Four lead hot cells in Bank-4 are utilized for the production of Mo-99/Tc-99m generators since 2005. The major systems including the Heat and Ventilated Air Conditioning (HVAC) system and the air cleaning system such as charcoal and HEPA filter trains to filter the radioactive contaminants are in operation. So are the systems such as power supply and distribution system, UPS, fire protection system, liquid radioactive waste ...
The analysis of complex fluids such as crude oils, fuels, vegetable oils and mixed waste streams poses significant challenges arising primarily from the multiplicity of components, the different properties of the components (polarity, polarizability, etc.) and matrix properties. We have recently introduced an analytical strategy that simplifies many of these analyses, and provides the added potential of linking compositional information with physical property information. This aspect can be used to facilitate equation of state development for the complex fluids. In addition to chemical characterization, the approach provides the ability to calculate thermodynamic properties for such complex heterogeneous streams. The technique is based on the advanced distillation curve (ADC) metrology, which separates a complex fluid by distillation into fractions that are sampled, and for which thermodynamically consistent temperatures are measured at atmospheric pressure. The ...
In front of the risks linked with the increase of the greenhouse gas emissions in the atmosphere, the decision makers must take into consideration first, the scientific advice of climatic change experts, and second, the considerable inertia of the climatic system. Thus, any action implemented so far will have an impact all along the 21. century and later whatever the future human activities. The aim of this memento is to sensibilize the decision makers about the possible consequences of their choice in terms of volume of greenhouse gases and of medium- and long-term evolution: 1 - stakes, role of local decision-makers (greenhouse effect and climatic change, France's international commitment, stakes, liabilities of local decision makers, decentralization laws, local plans of fight against greenhouse effect, public information and dialogue); 2 - urbanism and transports (urban displacements, alternatives to individual cars, collective ...
This facility has treatment capacity of 12 kg/hr, and is equipped with a furnace, two ceramic filter chambers, each of which hangs inside the 36 ceramic filter elements having mean pore size of 44 #mu#m. Three series of experiments were performed during a period from October 1972 to August 1973. The first was measurement of the change of pressure drop of the primary and the secondary filters after an operation of 52 days (352 hours). The pressure drop of the primary filter did not change during the operation, but the secondary brought a fairly large increment, from 79 to 140 mmAq. The second was measurement of the after-burning effect of the primary filter for the soot and tar in the off-gas. Through the after-burning most of the soot was removed from the off-gas, though the tar was not perfectly taken off. At the secondary filter, some of the tar was burnt, but most of it was caught by the filter as aerosol. The third was measurement of ...
A publication on Norwegian gas and gas export. The content is wide spread from use of gas in daily life via sub sea pipeline repair systems to an overview over tomorrows gas fields. (AG)
The nozzle-group regulation of steam turbines plays furtheron an important role in the operation of power stations owing to modern, adaptable control-technical valve timing possibilities. New procedures for a choice-connection of different nozzle areas via the control valves as well as the use of valve laps require, however, a differentiated consideration of the loss mechanism in the inlet area of the turbine, in order to be able to assess and minimize its specific heat consumption also at the operational points outside the layout- and calculation-technically fixed guarantee or valve points, respectively. The basic technical-physical stages to this are explained. (orig.) [Deutsch] Die Duesengruppenregelung von Dampfturbinen nimmt nicht zuletzt dank moderner, anpassungsfaehiger leittechnischer Ventilansteuerungsmoeglichkeiten weiterhin eine bedeutende Stellung beim Betrieb von Kraftwerken ein. Neue ...
The possibility of using Direct Flow Control (DFC) to avoid catastrophic accidents due to containment breaches in chemical plant is discussed. Recommendations are made for locating fluidic elements, and the effectiveness of simple DFC protection is analysed. More powerful methods of protection are outlined using spin diversion and the complementary properties of fluidic and conventional valves are exploited. (author).
This book includes the latest developments and covers pump performance, selection and operations, materials, seals and packings, effective fluid characteristics, filtration, piping systems, economics, valves, instrumentation, automatic controls, power transmission equipment, pump and pipeline heating, and more. An extensive data section contains formulas, charts, symbols, nomographs, and standard specification documents.
There is need of pressure surge analyses when valves or pumps are activated or piping systems fail (pipe rupture). Based on actual problems the influences of boundary conditions upon fluid simulation results are discussed. Hints concerning realistic dynamic analyses of piping systems are presented. Some of the simulations results are compared with measurements. (orig.)
This paper reviews power fluidics technology in the nuclear industry giving emphasis also on its potential uses in chemical plants and in flood and irrigation control. This is a technology of controlling process fluids by purely hydrodynamic methods, which should increase system reliability by eliminating valves, pumps and other fluid control devices that are often causes of failure. This review indicates that the hydrodynamics of fluidic components are not satisfactorily understood at present and may be more complex than similar theory in electronics.
An Ottawa-based company, ECS-Power Systems Inc., has successfully completed a series of tests on an innovative device called a hydrodynamic port (HDP), which makes it possible to automatically initiate and maintain emergency cooling of a nuclear reactor core by natural processes, without relying in any way on human intervention, instrumentation, electric power, valves or moving parts of any kind.
Due to the fast cooling of steam turbines, the shutdown time during maintenance or when repairing faults and damage can be shortened. This booklet describes various processes for cooling steam turbines. It is recommended that fast cooling should be planned in designing new plants and corresponding arrangements should be provided in the form of pipe connections and valves. (DG).
The purpose of the invention is to increase reliability in the operation of the device for advancing the base of a stoping unit. This is achieved because the device includes alternation hydraulic jacks of advance and control connected by hinges between themselves by the sections of the base and equipped with hydraulic locks, distributors of the hydraulic jacks of advance. In this case the hydraulic locks connected to the hydraulic jacks of control are doubled and connected to the distributors of the neighboring sections through reverse valves.
This report summarizes the research conducted during Budget Period One on the project ''Improved Natural Gas Storage Well Remediation''. The project team consisted of Furness-Newburge, Inc., the technology developer; TechSavants, Inc., the technology validator; and Nicor Technologies, Inc., the technology user. The overall objectives for the project were: (1) To develop, fabricate and test prototype laboratory devices using sonication and underwater plasma to remove scale from natural gas storage well piping and perforations; (2) To modify the laboratory devices into units capable of being used downhole; (3) To test the capability of the downhole units to remove scale in an observation well at a natural gas storage field; (4) To modify (if necessary) and field harden the units and then test the units in two pressurized injection/withdrawal gas storage wells; and (5) ...
A gas diffusion semiconductor electrode and solar cell and a process for gaseous fixation, such as nitrogen photoreduction, CO/sub 2/ photoreduction and fuel gas photo-oxidation are described. The gas diffusion photosensitive electrode has a central electrolyte porous matrix with an activated semiconductor material on one side adapted to be in contact with an electrolyte and a hydrophobic gas diffusion region on the opposite side adapted to be in contact with a supply of molecular gas.
Picosecond charge-collection transients measured for GaAs/AlGaAs HBTs following 3.0 MeV [alpha]-particle and 620 nm picosecond laser excitation reveal charge-collection efficiencies up to twenty-eight times smaller than for GaAs MESFETs, with [approximately]90% of the charge collected within 75 ps of the ionizing event. The small charge-collection efficiency of the HBTs is a consequence of the ultrafast charge-collection dynamics in these devices. The authors show that picosecond laser excitation reproduces nicely the ion-induced transients, providing a valuable tool for the investigation of charge-collection and SEU phenomena in these devices.
While it is difficult to prove that a specific material is causing contamination in a landfill, tests have been conducted at waste-to-energy facilities that indicate that household batteries contribute significant amounts of heavy metals to both air emissions and ash residue. Hennepin County, MN, used a dual approach for developing and implementing a special household battery collection. Alternative collection methods were examined; test collections were conducted. The second phase examined operating and disposal policy issues. This report describes the results of the grant project, moving from a broad examination of the construction and content of batteries, to a description of the pilot collection programs, and ending with a discussion of variables affecting the cost and operation of a comprehensive battery collection program. Three out-of-state companies (PA, NY) were found that ...
While it is difficult to prove that a specific material is causing contamination in a landfill, tests have been conducted at waste-to-energy facilities that indicate that household batteries contribute significant amounts of heavy metals to both air emissions and ash residue. Hennepin County, MN, used a dual approach for developing and implementing a special household battery collection. Alternative collection methods were examined; test collections were conducted. The second phase examined operating and disposal policy issues. This report describes the results of the grant project, moving from a broad examination of the construction and content of batteries, to a description of the pilot collection programs, and ending with a discussion of variables affecting the cost and operation of a comprehensive battery collection program. Three out-of-state companies (PA, NY) were found that ...
The book tries about the International and national aspects, natural gas situation, production, consumption, prices, demand projection, energetic plans, norms and laws of the natural gas in Colombia
This document provides information on the supply and disposition of natural gas to a wide audience. The 1996 data are presented in a sequence that follows natural gas from it`s production to it`s end use.
The origin of natural gas in the Japanese oil and gas fields are geochemically studied. Samples are taken from structural natural gas, surface gas seepage, water-dissolved natural gas and coal-field gas of the Japan Sea coast area. The origins of primary hydrocarbons are classified into bacteria gas and thermogenic gas, the latter being subclassified into gas in oil production zone with the per million deviation of the carbon isotope (/sup 13/C/sup 1/) of methane less than -35 and those gases with maturity higher than this. Surface gas seepage is subjected to migration and bacterial oxidation. Coal gas is similar to oil gas. The CO/sub 2/ concentration is 0 - 2% and /sup 13/CO/sub 2/ deviations from -30 - +30. The origin can be barely ...
BackgroundTo investigate the feasibility, the ease of implementation, and the extent to which community health workers with little experience of data collection could be trained...Full Text Available
Link to USGS home page Results of Electrical Resistivity Data Collected near the Town of Guernsey, Platte County, Wyoming By Robert R. McDougal, Jared D. Abraham, and Robert J....
Analytical method of theoretical simulation of collective hydrodynamic instabilities of intensive flows of discrete radiators, interacting with each other only through the coherent fields of their spontaneous radiation in corresponding media was suggested...
This purpose of this paper is to describe the optimizing Peripherally Inserted Central Catheter (PICC) insertion, revising data collection strategies, estimating workloads, and calculating the financial savings generated by the vascular access nurse (VAN)...
Objective: The paper describes the information needs of a state public health agency, compares needs to its library's collection, and evaluates collection development policy accordingly.Methods:...Full Text Available
To diagnose asymptomatic bacterial vaginosis (BV), self-sampled vaginal smears were collected during a study of risk factors for preterm birth in African American women. More than 90% of those...Full Text Available
System). From collecting terabytes of video footage to tracking the movements of the submarines, this software is essential to the science team as they explore unique structures on...
ObjectivesObjectives Not AvailableDescriptionThis proposal seeks to extend what is currently the most comprehensive offshore environmental data collection programme at a platform on the UKGS involving continuous collection of wave height and direction, wind speed and direction, current and wave particle kinematics. Data has been collected with this system since 1994 and the proposal is to extend this until 1999 thus providing an extensive set of storm data collected at 5Hz which will allow examination of the joint behaviour of wave, wind [continued...
In order to understand the physical processes concerned with the selective heating by ion cyclotron resonance and with the subsequent collection of heated particles, experiments were carried out with the extraction of lithium samples, enriched with "6Li isotopes. Probe and integral extractors allow to collect enriched Li at the end of the selective heating region. Surface density distribution on the collector and local isotopic content of lithium are measured, as a function of the screen height and the retarding potential. Dependence of the collected amount of lithium and of its isotopic content on the value of the magnetic field is also measured. 4 figs., 2 tabs., 5 refs.
A compartment model is described which is currently used by the Ministry of Agriculture, Fisheries and Food to calculate collective radiation exposure due to liquid radioactive wastes discharged to sea from UK nuclear sites. Collective dose is a useful indicator of the radiological impact of a disposal practice and is one of the quantities needed to show compliance with the ICRP system of dose limitation. The model has been used for the purposes of the Sizewell Inquiry to predict the collective radiation exposure from reactor operation at Sizewell and, on the basis of current Sellafield experience, correlations between dose and discharge for disposals of fuel reprocessing wastes. (author).
Many older homes are equipped with mercury-containing gas regulators that reduce the pressure of natural gas in the mains to the low pressure used in home gas piping. Removal of these regulators can...Full Text Available
Lipids in the stratum corneum (SC) are of major importance for the skin barrier function. Many different methods have been used for the collection of SC for the analysis of SC lipids. The objective of the present study was to validate the cyanoacrylate method for the collection of SC in relation to lipid analysis.
A non-recursive model is proposed and empirically tested with data of opponents of nuclear power. In explaining conventional and unconventional participation the theory of collective action is applied and modified in two respects: the perceived influence on the elimination of collective evils are taken into account; the selective incentives considered are non-material ones. These modifications proved to be valid: the collective good variables and non-material incentives were important determinants for the two forms of participation. Another result was that there is a reciprocal causal relationship between conventional and unconventional participation.
The authors report the personal techniques and the results of CT-guided percutaneous drainage of postoperative abdominal fluid collections. CT-guided percutaneous drainage offers many advantages over surgery: it is less invasive, can be repeated and requires no anesthesia, there are not surgery-related risks and lower morbidity and mortality rates. Moreover, subsequent hospitalization is shorter and costs are consequently reduced. The authors conclude that CT-guided percutaneous drainage is the method of choice in the treatment of postoperative abdominal fluid collections.
Sewage gas or biogas as a product of anaerobic digestion contains methane and carbon dioxide as its main components. Biogas is scrubbed off carbon dioxide in absorption columns and purified to natural-gas quality. The purified gas then is piped to the gas pressure control station and fed into the public network. Description of process and plant is given.
The RESF is utilized for storage of spent fuel under emergency conditions as well as for testing of FM heads. It receives cooling supply from the PHT Pressurizing pumps and after removal of decay heat from the spent fuel it goes to the D2O Storage Tank. The geometry of the RESF system is such that it can not sustain the thermosyphon loop during SBO, due to high frictional forces. To achieve the sustained thermosyphon, modifications in the design were suggested viz., removal of the steam trap and the relief valve above it and replacement by a solenoid valve (SV-16). In the event of SBO, SV-16 will open on 'RESF channel temperature high' signal and connect to FT D2O tank. The tank, being at atmospheric pressure and at lower elevation, will provide higher cooling flow rate through the RESF channel. D2O is periodically removed from the FT D2O tank by operating a Class-II pump intermittently. The analysis was done for the modified RESF system ...
The BMW four-cylinder two-valve engine was first launched in September 1987 as a 1.8 l engine and was described in detail in [1]. After initial optimisation for model year 94, four years later the engine has undergone a complete technical revision. From model year 98, the four-cylinder two-valve engine with appropriate exhaust emission technology will satisfy the EU3 class for exhaust emissions. (orig.) [Deutsch] Der BMW Vierzylinder-Zweiventilmotor wurde im September 1987 als 1,8-l-Motor erstmals vorgestellt und in [1] ausfuehrlich beschrieben. Nach einer ersten Optimierungsueberarbeitung zum Modelljahr 1994 wurde nun eine grundlegende technische Ueberarbeitung vorgenommen. Der Vierzylindermotor mit Zweiventiltechnik erfuellt als Antriebsaggregat in Verbindung mit einer entsprechenden Abgastechnik bereits ab Modelljahr 1998 die EU 3-Stufe fuer Abgasemissionen. (orig.)
The complete determination of stroke/throughput curves at steam turbines for arbitrary valve positions usually only follows after the fundamental layout of the control valves, of the possible nozzle segments and of the turbine blading. A general fundamental equation and some design norms based on it are presented which may serve already before a fluidic layout of the turbine in detail as an optimizing predetermination of the properties concerning pressure loss and control statics of the metering components in the admission area. (orig.) [Deutsch] Die vollstaendige Bestimmung der Hub-/Durchsatzkurven an Dampfturbinen fuer beliebige Ventilstellungen erfolgt ueblicherweise erst nach der Grundauslegung der Stellventile, etwaiger Duesensegmente und der Turbinenbeschaufelung. Es werden eine allgemeine Grundgleichung und einige auf ihr aufbauende Entwurfsregeln angegeben, die zu einer optimierenden Vorabbestimmung der druckverlustbezogenen ...
An original device and a method of its application for restoring of the function of relatively incompetent valves (both patented) are elaborated. Application of the new device allows to lower the difficulty of surgical treatment, to decrease the duration of operation and post-operative period. The long-term results of six-year long experience of its application are presented. The patients examination after 2,5-3,0-year post-operation period shows perfect vein valve correction. A device for stone extraction from tubular organs (patented) fabricated with titanium nickelide superelastic alloy is presented. The new suggested design is free of the drawback inherent in the previous one. The working element of the device is formed as a truncated cone or a truncated cone coaxial with the cylinder (the previous design was formed as a full cone) that prevents overstraining and residual strain accumulation during the manipulation process. Since the first ...
Platelet deposition on bovine pericardial-tissue mitral-valve prostheses in 11 dogs was observed noninvasively by use of "1"1"1In-labeled platelets and quantified after sacrifice at one (n . 3), 14 (n . 3), and 30 (n . 5) days postimplantation (300-400 microCi of labeled platelets having been injected 24 hours previously). Thrombosis on the sewing ring and pericardial leaflets at one and 14 days and on the leaflets at 30 days was delineated in scintiphotos. In vitro quantification (% injected dose) indicated that the leaflets, sewing ring, and perivalvular tissue retained 0.904% of labeled platelets at one day postimplantation, 0.198% at 14 days, and 0.040% at 30 days. Platelet half-life was reduced to 38 hours at 21 days postimplantation but returned toward the normal (50 hours) with fibrous ingrowth in the sewing ring. Microembolism in lung and kidney, as measured by tissue/blood radioactivity ratio, also was decreased significantly at 30 days. "1"1"1In-labeled ...
BackgroundEchocardiography has been debated as an adjunct for transcatheter aortic valve replacement (TAVR). The aim of this prospective study was to comparatively evaluate intraprocedural guidance using intracardiac echocardiography (ICE) and transesophageal echocardiography (TEE). MethodsFifty high-risk patients with severe aortic stenosis scheduled for TAVR were randomized to either guidance using ICE (group 1; n = 25) or monitoring using TEE (group 2; n = 25). ResultsIn contrast to TEE, ICE allowed continuous monitoring. The need for probe repositioning during the procedure was much lower in group 1 (0.1 +- 0.3 vs 5.7 +- 0.7 maneuvers, P P = .003). Both coronary ostia were more frequently visualized in group 1 (18 vs 2 cases, P n = 25, r2 = 0.90, P n = 11, P = .012), but ICE did not (m...
In-service Test (IST) of the nuclear power plant is very important to maintain the safety of the plants. The safety features of nuclear power plant are based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear power plant to keep operational readiness of pumps and valves. Because of the importance of the IST, most of nuclear power plants should designate the IST department and personnel. Because the nuclear power plants of Korea have several types and the designs and operations are different from each other, the methods and experiences are various for the management of the IST program. However, there are no medium to communicate with each other and exchange the tips and information about IST program and education and discussion would be required to apply a consistent code. The nature of the IST Standardization Management Data Base (SMDB) is to exchange opinions and documents about IST program and ...
In order to evaluate the integrated performance of RELAP5/MOD3/CANDU"+ for CANDU operational transient analysis, we assesed the code to the D_2O leakage event occurred at Wolsung-I, 600 MW(e) CANDU reactor, on Oct. 20, '94. D_2O leakage event was initiated by stuck opening of liquid relief valve No.4 in primary coolant pressure and level control system. Assessment calculation was performed for the plant transients up to 1000 seconds after the initiating event. Calculation results are compared with those measured in primary heat transport system, pressure and inventory control system and boiler secondary system. Comparison with the plant trip log shows that the RELAP5/CANDU"+ is able to simulate the plant transients properly, from which we can conclude that the RELAP5/CANDU"+ is validated for application to CANDU operational transient analysis. CANDU specific models used in the assessment are fuel bundle heat transfer model, decay heat model and MOV(Motor Operated ...
This study provides an analysis of potential changes that may take place in a Uranium Mill Tailings Remedial Action (UMTRA) Project disposal cell cover system as a result of plant biointrusion. Potential changes are evaluated by performing a sensitivity analysis of the relative impact of root penetrations on radon flux out of the cell cover and/or water infiltration into the cell cover. Data used in this analysis consist of existing information on vegetation growth on selected cell cover systems and information available from published studies and/or other available project research. Consistent with the scope of this paper, no new site-specific data were collected from UMTRA Project sites. Further, this paper does not focus on the issue of plant transport of radon gas or other contaminants out of the disposal cell cover though it is acknowledged that such transport has the potential to be a significant pathway for contaminants to reach the ...
This study provides an analysis of potential changes that may take place in a Uranium Mill Tailings Remedial Action (UMTRA) Project disposal cell cover system as a result of plant biointrusion. Potential changes are evaluated by performing a sensitivity analysis of the relative impact of root penetrations on radon flux out of the cell cover and/or water infiltration into the cell cover. Data used in this analysis consist of existing information on vegetation growth on selected cell cover systems and information available from published studies and/or other available project research. Consistent with the scope of this paper, no new site-specific data were collected from UMTRA Project sites. Further, this paper does not focus on the issue of plant transport of radon gas or other contaminants out of the disposal cell cover though it is acknowledged that such transport has the potential to be a significant pathway for contaminants to reach the ...
This spring, Newfoundland will send off a floating production, storage and offloading (FPSO) vessel to the offshore Terra Nova field. The Terra Nova will proceed southeast through Bull Arm, then northeast out of Trinity Bay, then heads southeast to the Jeanne d'Arc Basin on the Grand Banks. The Terra Nova is expected to produce 115,000 barrels of oil per day for six years, when it reaches full capacity. The consortium, headed by Petro-Canada as senior ownership partner and operator, built an environment protection program into every aspect of the project. Some of the features of the environment protection program include glory holes excavated on the ocean floor for the protection of production equipment from icebergs, to a flare stack on the platform, which has four legs to provide stability in rough seas. The FPSO was designed to withstand sea ice, icebergs, and severe winter storms. Flow lines are also protected, and in the event that a line is damaged, sea water will leak ...
Natural Resources Canada commissioned an informal survey in which 18 organizations, mainly utilities from across Canada were contacted by letter or fax to gather data regarding unit energy consumption (UEC) of space heating, domestic hot water (DHW) heating and appliances. The data was used in updating and refining the residential energy end-use model used at NRCan. The survey included energy load, UEC, efficiency, and per cent saturation for both space heating and water heating equipment for all fuel types including electric, natural gas, oil, wood and propane used in single detached, single attached, apartment and mobile homes. A list of UEC and per cent saturation for major appliances such as refrigerators, freezers, clothes washers and dryers, cooktop/ovens, central air-conditioners, and lighting is also included in the survey. The collected data was presented separately for each organization. The UEC estimates for appliances range from ...
The aim of the project is to study the conditions and processes occurring in permanently frozen crystalline bedrock, with special reference to deep (i.e., several hundreds of meters) bedrock conditions. The target of the study is the Lupin mine in Nunavut Territory, Northern Canada. The results may be utilized in assessing the long-term performance of deep underground constructions (e.g., nuclear waste repositories) in cooling climatic conditions. In Phase I of the project versatile background information was collected from the site e.g., on climate, geology and on hydrogeological and hydrogeochemical conditions. During Phase II a broad range of research was conducted including (i) electromagnetic soundings to investigate the distribution of permafrost in the surroundings of the mine; (ii) drilling of three research boreholes at the base of the permafrost for groundwater research; (iii) application of borehole video surveys to study the distribution of open ...
Probabilistic risk analysis has historically been developed for situations in which measured data about the overall reliability of a system are limited and expert knowledge is the best source of information available. There continue to be a number of important problem areas characterized by a lack of hard data. However, in other important problem areas the emergence of information technology has transformed the situation from one characterized by little data to one characterized by data overabundance. Natural disaster risk assessments for events impacting large-scale, critical infrastructure systems such as electric power distribution systems, transportation systems, water supply systems, and natural gas supply systems are important examples of problems characterized by data overabundance. There are often substantial amounts of information collected and archived about the behavior of these systems over time. Yet it can be difficult to ...
According to ICRP 60 and European-Directive 96/29, Naturally Occurring Radioactive Materials (NORM) and Technical Enriched Naturally Occurring Radioactive Materials (TENORM) have to take the radiation protection of the general population as well as of workers into account. The German radiation protection regulations stress that particularly. In connection with these regulations, various measurement programs have been and still are performed to investigate the relevant exposure paths. One of these programs is the determination of the intake of natural occurring radionuclides of the uranium decay series in individuals of the public, in exposed regions and houses and also at NORM workplaces by excretion analysis. Excretion analysis surveillance is one of the common tools for internal dosimetry. Sources of primordial radionuclides could be the ingestion of foodstuff and water and the incorporation of (mostly airborne) pollution on work places. The main focus in this report is set upon the ...
The H-SAPS (Hydrogen Stand-Alone Power System) project, an EU project within the ALTENER programme in the period 2002-2004, was initiated to determine the potential for the introduction of environmentally benign hydrogen technology in what is believed to be a near-term market, namely stand-alone power systems (SAPS). The objective of the project was to examine the technological, political, social and economical factors affecting the emergence of hydrogen technology in the stand-alone power system market today and in the future. The scope of the project was limited to small and medium sized stand-alone power systems, up to a few hundred kilowatts (kW) power rating and based on renewable energy as the primary energy source. The work was divided into five phases: (1) Inception, (2) Data collection and analysis, (3) Market analysis and barrier removal, (4) Dissemination, and (5) Final report. Separate reports were written on these topics, and later summarised this ...
The Stardust sample return capsule will return to Earth in January 2006 with primitive debris collected from Comet 81P/Wild-2 during the fly-by encounter in 2004. In addition to the cometary particles embedded in low-density silica aerogel, there will be microcraters preserved in the Al foils (1100 series; 100 {micro}m thick) that are wrapped around the sample tray assembly. Soda lime spheres ({approx}49 {micro}m in diameter) have been accelerated with a Light Gas Gun into flight-grade Al foils at 6.35 km s{sup -1} to simulate the capture of cometary debris. The experimental craters have been analyzed using scanning electron microscopy (SEM) and x-ray energy dispersive spectroscopy (EDX) to locate and characterize remnants of the projectile material remaining within the craters. In addition, ion beam induced secondary electron imaging has proven particularly useful in identifying areas within the craters that contain residue material. Finally, ...
This paper presents efforts to date and prospective goals towards development of a modelling and analysis framework which is comprehensive enough to address the global climate crisis, and detailed enough to provide policymakers with concrete targets and achievable outcomes. In terms of energy efficiency policy, this requires coverage of the entire world, with emphasis on countries and regions with large and/or rapidly growing energy-related emissions, and analysis at the 'technology' level-building end use, transport mode or industrial process. These elements have not been fully addressed by existing modelling efforts, which usually take either a top-down approach, or concentrate on a few fully industrialized countries where energy demand is well-understood. Inclusion of details such as appliance ownership rates, use patterns and efficiency levels throughout the world allows for a deeper understanding of the demand for energy today and, more importantly, over the ...
A community greenhouse gas emission and energy inventory is an important tool to help local governments plan, implement and monitor climate change mitigation strategies and sustainable energy systems. Inventories can also facilitate a number of other local priorities such as air quality management; integrated land-use and transportation planning; infrastructure optimization and planning; and community economic development planning. The British Columbia government's community energy and emissions inventory initiative (CEEI) intends to collect and centralize high-quality geocoded data to generate high-value community inventories for the province's 185 local governments. This report presented strategic guidance for a comprehensive community emissions inventory system based on a high level review of international best practices. The report described the project objective and scope; guiding principles; research methodology; and inventory ...
An American Society of Mechanical Engineers task group on stainless steel weld materials was organized to determine the need for ferrite measurements of production welds required by the US Nuclear Regulatory Commission Regulatory Guide 1.31 (Rev. 1). The task group studied paired ferrite measurements (i.e., calculated and measured ferrite numbers (FNs) for the material qualifications versus measured ferrite numbers for corresponding production welds (PWs)). Our purpose was to compare delta-ferrite content as measured in the filler metal weld qualification pad with that in the resultant PW. Welds made predominantly by three common processes (submerged arc, shielded metal arc, and gas tungsten arc) were included in the study. Weld metals investigated included types 308, 308L, 316, and 316L stainless steel. An initial evaluation of the paired ferrite measurements was made by the task group, and specific conclusions and recommendations were made. We describe the ...
A nitrogen liquefier and computer controlled valving system have been added to the Bevatron cryoliner vacuum system to cut operating costs by reducing liquid nitrogen consumption. The computer and interface electronic systems, which control the temperatures of twenty-eight liquid nitrogen circuits, have been chosen and designed to operate in the Bevatron's pulsating magnetic field. The nitrogen exhaust is routed back to a liquefier, of about five kilowatt capacity, liquefied, and rerouted through the cooling circuits. A description of the system and operating results are presented.
In order to ensure a power balance in an electrical network a spinning reserve has to be capable of activation within seconds. However, because of the need to vary the fuel flow in the steam generator, the run-up of output takes minutes. The required capacity response is therefore achieved by storage of steam from the steam generator. In this process the turbine control valves come into action in a specific manner. The paper describes the importance of the initial reserve for unit capacity control. (orig.).
Object: To limit the discharge amount of reactor water in a primary system at the time of scram to prevent excessive outflow of reactor water outside the system. Structure: A signal from an upper limit position indicator detects the fact that control rods are completely inserted when the reactor is urgently stopped and the detection signal causes a valve in an outflow line of the discharge water from a control rod driving mechanism to be closed to limit the amount of discharge flown into the scram discharge vessel, thus preventing outflow of reactor water in the primary system after the scram has been initiated. (Kamimura, M.).
A dual fuel engine control system for controlling the power output of a dual fuel compression ignition engine. The engine includes mixing means for combining an oxidizer and a primary fuel at a substantially constant ratio of oxidizer to primary fuel. The power output of the engine is controlled through the use of a throttle valve controlling the quantity of combustible mixture delivered to the combustion chamber. The fuel control system minimizes the quantity of ignition fuel required by controlling the quantity of combustible mixture rather than the fuel of air ratio. (author) figs.
Isolated laevocardia combined with corrected transposition of the great arteries and complete situs inversus is rare. Due to discordant interrelationships between atria and ventricles and between ventricles and great arteries, both anomalies result in a normal circulation. In the presented case no associated cardiac malformations were present and the 55-year-old woman remained symptom-free for a long time until she developed an acquired valve disease. A systematic approach to chamber localisation in complex morphologic lesions of the heart is reviewed, and the value of CT, which can be applied successfully in older children and adults is demonstrated. (orig.).
The objective of this study is to establish evaluation and verification guideline for the APR 1400 and to investigate the thermal-hydraulic characteristics for fluidic device is analyzed using FLUENT. The scope and major results of research are flow characteristics for fluidic device. In this study, three-dimensional numerical model for fluidic device is developed adequately for, and results are compared with experimental data performed by VAPER (VAlve Performance Evaluation test Rig) in KAERI with an aim to verify numerical simulation. In addition, the parametric study has also carried out to investigate the effect of major parameters such as velocity and pressure inside FD chamber.
All power plant engineers face the problem of peak power demands. Pumped storage plants are used to generate peak load power by pumping up water utilizing off-peak energy of hydrothermal and thermonuclear plants. This is the first accessible text/reference to cover hydroelectric power generation with emphasis on engineering to meet peak power demands by means of pumped storge plants, tidal power plants, and low head power generation. Text covers hydrology, mechanical and electrical equipment, accessories such as penstocks and valves, and civil engineering considerations. Contains descriptions of several existing plants. Includes 200 diagrams and 50 photographs.
All power plant engineers face the problem of peak power demands. Pumped storage plants are used to generate peak load power by pumping up water utilizing off-peak energy of hydrothermal and thermonuclear plants. This is a reference to cover hydroelectric power generation with emphasis on engineering to meet peak power demands by means of pumped storage plants, tidal power plants, and low head power generation. Text covers hydrology, mechanical and electrical equipment, accessories such as penstocks and valves, and civil engineering considerations. Contains descriptions of several existing plants. Includes 200 diagrams and 50 photographs.
In this paper a comparison between calculations of severe accidents occurred from WWER-1000 with ASTEC code specified for an event of full unloading with relief valves stuck opened with no hydroaccumulators intervention is presented. The purpose of the analyses provided is to present the relationship between the improvements of the actual version (ASTEC Vl.2 rev. 1) and ASTEC V1.1 p2 like: code modifications, incoming data improvements. Such discrepancies are to be examined. Case by case suggestions for ASTEC improvements are to be provided.
In the procedure of the hydraulic control system analysis, a linearized approximate equation described by the first order term of Taylor's series has been widely used. Such a linearized equation is effective just near the operating point. In this study, the authors estimate computational errors in the process of applying the existing linearized equation stated above. For evaluating the computational accuracy in practical applications of the linearized equations, dynamic behaviors of hydraulic control systems are investigated through simulations with several kinds of representative hydraulic systems and the linearized equations suggested in this study.
The development of new electro-optical instrumentation for studying the annular dispersed two-phase flow regime is described. The system measures the thickness of the water film and droplet size and velocity distributions which would be encountered in such a flow regime. The water film thickness is measured by an improved capacitance method with a short time constant using newly developed sensor electrodes. The electrodes are made flush with the inner wall of a cylindrical tube and do not disturb the flow. In the test equipment, steady, laminar flow of water along the inner wall of the tube is controlled by appropriate valves and a porous jacket while droplets are introduced by means of a special spray nozzle.
As an application of ART2 neural networks, computer aided monitoring of pump efficiency is successfully examined for an industrial waste-liquid treatment process with measured data of valve openness and liquid flow rates. By running the neural networks in parallel, we confirm that accuracy to detect system changes is good, and the adjustment of classifier parameters is relatively easy. Investigating the resulting classes carefully, frequency of each class is correlated with pump efficiency. The relative amount of variables are also related to the classes. (author)
A solid electrolytic capacitor having a solid electrolyte comprising manganese dioxide dispersed in an aromatic polyamide capable of further cure to form polyimide linkages, the solid electrolyte being disposed between a first electrode made of valve metal covered by an anodic oxide film and a second electrode opposite the first electrode. The electrolyte autogenously produces water, oxygen, and hydroxyl groups which act as healing substances and is not itself produced pyrolytically. Reduction of the manganese dioxide and the water molecules released by formation of imide linkages result in substantially improved self-healing of anodic dielectric layer defects.
We report the performance of a micro gas turbine on biomass producer gas and mixtures of biomass producer gas with natural gas. The micro gas turbine delivers full power on gas mixtures with a heating value of at least 15 MJ/Nm{sup 3}. For gas of lower heating value, the maximum fuel gas flow limits the attainable power. The lower limit for stable operation is about 8 MJ/Nm{sup 3}. The gross efficiency of the micro gas turbine depends on output power but not on the gas heating value, within our measurement accuracy. Above 70% of full power, emissions of CO and NO are 40 and 10 times lower than those of a gas engine of similar size. At part load below 70% of full power, the micro gas turbine burner switches to a different operating mode ...
The linearized collective Schroedinger equation for nuclear quadrupole surface vibrations incorporates a new spin degree of freeedom with a spin value of 3/2. We use this equation to describe the low energy spectrum of certain even-odd Ir nuclei which have a spin 3/2 in their ground state. For that purpose we explicitly introduce collective spin-dependent potentials which simulate the interaction of the valence nucleon with the core. The linearized Schroedinger equation is transformed into an effective Schroedinger equation with collective spin-dependent potentials. Already collective spin-orbit couplings of SO(3) and SO(5) type are sufficient to reproduce the lowest excited states of even-odd Ir nuclei. (orig.).
The linearized collective Schroedinger equation for nuclear quadrupole surface vibrations incorporates a new spin degree of freeedom with a spin value of 3/2. We use this equation to describe the low energy spectrum of certain even-odd Ir nuclei which have a spin 3/2 in their ground state. For that purpose we explicitly introduce collective spin-dependent potentials which simulate the interaction of the valence nucleon with the core. The linearized Schroedinger equation is transformed into an effective Schroedinger equation with collective spin-dependent potentials. Already collective spin-orbit couplings of SO(3) and SO(5) type are sufficient to reproduce the lowest excited states of even-odd Ir nuclei. (orig.).
Six patients with diskitis following lumbar disk surgery were investigated by Computed Tomography (CT). Four patients underwent CT in a rather early phase of the disease (5-37 days after the onset of the symptoms): a posterior paravertebral fluid collection was always recognized, while the plain film was normal. Later on (2-4 months), the classical signs of diskitis were evident, with both CT and the plain film. The collection was always present at CT. A reintervention, performed on 3 patients, revealed the purulent content of the collections. It seems reasonable to suggest a relationship between the collection and the subsequent diskitis; the collection is probably an early sign of the disease. Its detection is of grat value, because it could allow an immediate and adequate therapy. The authors stress the usefulness of performing CT in an early phase on this kind of symptomatic ...
The most effective way to generate electricity out of biomass is the gasification and the use of the gas in a gas engine. The conversion of the organic carbon with the gasification of biomass is higher than 95 %. Depending on the gasification concept, the efficiency of gasifiers is found between 70 and 90 %. If the pyrolysis gas is used in a gas engine, an electric efficiency of about 26 % referring to the primary amount of energy can be obtained. With efficient gas cleaning (cleaning for tar and dust), pyrolysis gas is well qualified for engine combustion. Through modern state of engine controlling there are ways to have complete control of the fluctuations in the gas composition. Furthermore, the minor calorific value of offered wood gas poses no problem for turbo charged lean-burn gas engines. ...
This patent describes an electrodeless lamp. It comprises: a microwave cavity; a source of microwaves in communication with the cavity; a lamp envelope containing a plasma-forming medium mounted within the microwave cavity; a gas manifold for feeding gas to at least one gas passageway for directing a stream of gas to the outer surface of the envelope; a gas leak passageway leading from the gas manifold; a conductive mesh assembly for retaining microwaves within the cavity and permitting light to be emitted from the cavity. The assembly including gas flow blocking means for preventing the flow of gas through the gas leak passageway when the screen is in place in the lamp; and means for shutting off the source of microwaves when the gas pressure in the manifold drops below a ...
Appendices to this summary consist of twelve individual status reports that will be available through the National Technical Information Service (NTIS) in the United States and of course limited copies will be available through NATO. The twelve report titles which are appendices to the summary are: (A) Status Report on the Limestone/Sludge Flue Gas Desulfurization Process; (B) Status Report on the Lime/Sludge Flue Gas Desulfurization Process; (C) Status Report on the Double Alkali/Sludge Flue Gas Desulfurization Process; (D) Status Report on the Sea Water Scrubbing Flue Gas Desulfurization Process; (E) Status Report on the Limestone/Gypsum Flue Gas Desulfurization Process; (F) Status Report on the Lime/Gypsum Flue Gas Desulfurization Process; (G) Status Report on the Double Alkali/Gypsum Flue Gas Desulfurization Process; (H) Status Report on ...
Gas hydrates have impacted the oil and gas industry since 1934, when they were first found to plug pipelines. Today we know that in deep oceans and in permafrost, very substantial gas reserves are present in hydrated form. Concerns are being raised about in situ dissociation for both energy and greenhouse implications upon methane release. In Japan work is underway to consider the storage of carbon dioxide, concentrated in clathrates. This talk will deal with some basic questions. Why should we be interested in gas hydrates? What are gas hydrates? How do gas hydrates form? How might hydrates impact on the energy/environmental picture?
This book discusses the progress and problems of current interest in gaseous dielectrics and their use, with special emphasis on insulation in high-voltage transmission lines and substations. Topics covered include: basic physics of gaseous dielectrics; basic mechanisms; gas decomposition, reactions and toxicity; diagnostics and field probes; gases and mixtures for GIS transformers and circuit breakers; gaseous media for discharge chemistry and etching/corona; gas engineering for pulsed power and switching; gas breakdown under steep-fronted voltages; new developments in gas-insulated equipment and gas handling; gas/insulator interface/flashover; and quality control in testing gas-insulated equipment. Contains approximately 85 papers.
Gas hydrates are crystalline substances composed of water and gas, in which a solid-water-lattice accommodates gas molecules in a cage-like structure. Gas hydrates are globally widespread in permafrost regions and beneath the sea in sediment of outer continental margins. While methane, propane, and other gases can be included in the clathrate structure, methane hydrates appear to be the most common in nature. The amount of methane sequestered in gas hydrates is probably enormous, but estimates are speculative and range over three orders of magnitude from about 100,000 to 270,000,000 trillion cubic feet. The amount of gas in the hydrate reservoirs of the world greedy exceeds the volume of known conventional gas reserves. Gas hydrates also represent a significant drilling and production hazard. A fundamental question ...
Gas hydrates are crystalline substances composed of water and gas, in which a solid-water-lattice accommodates gas molecules in a cage-like structure. Gas hydrates are globally widespread in permafrost regions and beneath the sea in sediment of outer continental margins. While methane, propane, and other gases can be included in the clathrate structure, methane hydrates appear to be the most common in nature. The amount of methane sequestered in gas hydrates is probably enormous, but estimates are speculative and range over three orders of magnitude from about 100,000 to 270,000,000 trillion cubic feet. The amount of gas in the hydrate reservoirs of the world greedy exceeds the volume of known conventional gas reserves. Gas hydrates also represent a significant drilling and production hazard. A fundamental question ...
We report the performance of a commercial recuperated micro gas turbine on biomass producer gas and mixtures of biomass producer gas with natural gas. The biomass producer gas, obtained by gasification at 850{sup o}C with air at atmospheric pressure, contains about 7% H2, 17% CO, 15% CO2, 4% CH4, 2% other hydrocarbons, 2% H2O, and a balance of N2 and Ar from air. It has a net heating value of about 6 MJ/(Nm{sup 3}). The micro gas turbine delivers full power (30 kW{sub e}) on gas mixtures with a net heating value of at least 15 MJ/(Nm{sup 3}). For gas of lower heating value, the maximum fuel gas flow allowed by the fuel control unit limits the attainable power. At reduced power, the lower limit for stable operation is a net heating value of about 8 MJ/(Nm{sup 3}). The gross efficiency of the micro ...
The situation of natural gas in the Federal Republic of Germany is described, with particular emphasis on the advantages and consequences of natural gas supply. The brochure discusses the role of natural gas on the energy market, the reliability of natural gas supply, the environmental impacts, the energy-saving effect of natural gas, natural gas prices, the competitive strength of the German gas industry, and the long-term reliability of natural gas supply. (orig.) [German] Die Situation des Erdgases in der Bundesrepublik Deutschland wird beschrieben, wobei die wichtigsten Vorteile und Auswirkungen der Erdgasversorgung besonders hervorgehoben werden. Es geht um die Stellung des Erdgases im Energiemarkt, die Sicherheit der Energieversorgung, Umweltschutz, Energieeinsparung durch Erdgaseinsatz, Erdgaspreise, ...
Effects of combustion conditions on the critical calorific value of flame blowout were reported for low calorific gas on the assumption of using coal derived gaseous fuel. Further, calculations of adiabatic flame temperature by using chemical equilibrium calculation were conducted in order to get a possibility of increasing exit gas temperature of gas turbine combustor to 1,300 C for low calorific value gas fuel. As a result, effects of (1) fuel composition, (2) preheating fuel temperature, (3) calorific value, and (4) combustion air velocity and fuel nozzle diameter, on the critical calorific values of flame blowout were clarified. In increasing exit gas temperature of gas turbine combustor to 1,300 C when using low calorific value gas fuel, it is essential to get an advanced cooling technology for the gas turbine ...
The genetic type, source and charging history of natural gas in the Yulin gas field in the Ordos Basin have been studied by combining the carbon isotopic composition of natural gas and geochemical characteristics of light hydrocarbons with carbon isotope fractionation model results and fluid inclusion analysis. The carbon isotopic composition of methane and ethane in the Yulin gas field is relatively enriched in {sup 13}C with {delta}{sup 13}C{sub 1} values ranging from - 35.3 permille to - 29.8 permille (average value = - 32.4 permille) and {delta}{sup 13}C{sub 2} ranging from - 26.3 permille to - 23.5 permille (average value = - 24.8 permille). The C{sub 7} light hydrocarbons are predominated by methylcyclohexane, accounting for 65.8% to 80.9% (average value = 71.6%), which is characteristic of coal-derived gas. Furthermore, the gas geochemistry indicates ...
The production, principal applications, characteristics and properties, advantages of the gas natural is showed. A sectorial overview of the ceramic industry and the utilization of the natural gas in the ceramic industry is presented. The expectations are systematized and the impact of the natural gas utilization in the ceramic industry is evaluated. Some conclusions are withdrawn and recommendations suggested.
A combined gas/steam turbine process includes a high-pressure furnace and a high pressure gasification unit with a mounted upstream of a combustion chamber there is a gas turbine with a waste heat system. Combustion heat which is not needed to heat the flue gas to combustion temperature is released from the furnace and transferred to ths combustion air going into the combustion chamber.
Nomographs have been developed to simplify site performance estimates for various types of gas turbine engines used for industrial applications. The nomographs can provide valuable data for engineers to use for an initial appraisal of projects where gas turbines are to be considered. General guidelines for the selection of gas turbines are also discussed. In particular, site conditions that influence the performance of gas turbines are described.
The budding natural gas markets in East Europe attract a great deal of interest from natural gas industries in the Western countries. Dutch companies, institutions and the government, too, are active in this market. So far the results have not been spectacular. An analysis is made of the present situation and the Dutch approach
The Schroedinger equation for nuclear quadruple surface vibrations is linearized with the consequence that a new spin degree of freedom appears in the wave function of the linearized equation. This spin is called collective spin and has a value of 3/2. The linearized Schroedinger equation for quadrupole vibrations is used for the description of certain collective aspects of even-odd {sup 187,189,191}Ir nuclei which have a spin 3/2 in their ground state. As a potential we use the {gamma}-soft collective potential of the neighboring even-even nuclei, which is inserted into the linearized Schroedinger equation via a scalar coupling. This leads to a collective spin-dependent fine structure splitting of the energy levels governed by a collective SO(5) spin-orbit coupling and a correction to the kinetic energy. Further, we consider explicitly spin-dependent potentials which effectively ...
The Schroedinger equation for nuclear quadruple surface vibrations is linearized with the consequence that a new spin degree of freedom appears in the wave function of the linearized equation. This spin is called collective spin and has a value of 3/2. The linearized Schroedinger equation for quadrupole vibrations is used for the description of certain collective aspects of even-odd "1"8"7","1"8"9","1"9"1Ir nuclei which have a spin 3/2 in their ground state. As a potential we use the #gamma#-soft collective potential of the neighboring even-even nuclei, which is inserted into the linearized Schroedinger equation via a scalar coupling. This leads to a collective spin-dependent fine structure splitting of the energy levels governed by a collective SO(5) spin-orbit coupling and a correction to the kinetic energy. Further, we consider explicitly spin-dependent potentials which ...
This report summarises nearly 20 biosphere reports and gives a synthesis of the work performed within the SR-Site Biosphere project, i.e. the biosphere part of SR-Site. SR-Site Biosphere provides the main project with dose conversion factors (LDFs), given a unit release rate, for calculation of human doses under different release scenarios, and assesses if a potential release from the repository would have detrimental effects on the environment. The intention of this report is to give sufficient details for an overview of methods, results and major conclusions, with references to the biosphere reports where methods, data and results are presented and discussed in detail. The philosophy of the biosphere assessment was to make estimations of the radiological risk for humans and the environment as realistic as possible, based on the knowledge of present-day conditions at Forsmark and the past and expected future development of the site. This was achieved by using the best available ...
Ion acceleration has now been demonstrated with the IFA-2 collective ion accelerator system. The IFA-2 system is described, photoionization experiments are summarized, and ion results are presented. Using a 1 MeV electron beam and a 30 cm acceleration length, IFA-2 has produced 5 MeV H/sup +/, 10 MeV D/sup +/, and 20 MeV He/sup + +/. This means that accelerating fields of 33 MV/m over 30 cm have been achieved with a controlled collective accelerator for the first time.
Purpose - The purpose of this paper is to describe the processes and procedures utilized by Jacksonville State University's Houston Cole Library to digitize an oral history collection and provide access to it through the Library's catalog, web presence, and the state-wide digital repository initiative, Alabama Mosaic (see www.alabamamosaic.org). Design/methodology/approach - The paper is based on the Library's experiences in acquiring, digitizing, creating metadata for and making accessible a collection of oral histories. Findings - The paper describes the obstacles overcome, issues encountered, procedures established, and ramifications of the project. Practical implications - Many institutions are currently digitizing unique collections as part of repository initiatives, both institutiona...
We discuss the algebraic structure of the generator coordinate method for triaxial quadrupole collective motion. The collective solutions are classified according to the representations of the permutation group of the intrinsic axes. Our method amounts to an approximate angular-momentum projection. We apply it to a study of the spherical-to-deformed-shape transition in light even strontium isotopes {sup 78-88}Sr. We find that triaxial configurations play a significant role in explaining the structure of the transitional isotopes {sup 80-82}Sr. (orig.).
This article puts the case for coal fired combined cycle gas turbine (CCGT) power plants. The need to gasify the coal for the CCGT, use of fluidised bed combustors or gasification systems, the difference in prices of coal and natural gas, and coal and natural gas reserves are discussed. (UK)
Natural gas is essential to the world economy. Gas now accounts for almost a quarter of OECD primary energy requirements and is expected to become the second most important fuel in the world in the next decade. Industrial and residential consumers increasingly rely on natural gas to keep their houses warm, their lights on and their factories running. Meanwhile the gas industry itself has entered a new phase. Where gas used to be restricted to regional markets, it is now increasingly traded on a global scale. While gas production and transport requires long-term investment, now it is optimised on a short-term basis. Demand continues to grow, but local gas production has become much more expensive. How should we react? How will demand be satisfied? What changes are required to promote flexibility and trade? What are the implications for ...
Mist eliminators for flue gas desulphurisation units remove liquid droplets entrained in the flue gas leaving the SO/sub 2/-absorber vessels. The commercial designs currently available are described.
The purpose of this project was to build a long-range, parallel hybrid gas/electric vehicle capable of driving beyond the communter capabilities of series hybrid vehicles. It was envisioned that since the gas engine would be able to independently propel t...
This is a point shapefile showing Traffic sign locations at Colorado National Monument. The coordinates for this dataset were collected using a Trimble Geo-Explorer 2 GPS reciever....
A method is described for determining the particulate contamination in miniature ball bearings in which the bearing is flushed with a solvent that is then filtered. The particles that are collected on the filter are examined by optical microscopy.
... Congo. It is probable that the type locality Matadi is in error and is the location from ... specimens of this species have been collected between Matadi and Luozi. (click map to view...
... the high current induction linear accelerator of the nanosecond range, meant to be used as injector in the collective ion accelerator, are presented. ...
This issue is the collection of the papers on progress of researches by common utilization of JAERI nuclear facilities. The 43 of the papers are indexed individually. (J.P.N.)
This document is a collection of spreadsheets detailing on a county by county basis the agricultural crop, agricultural wastes, municipal wastes, and industrial wastes of Virginia that are potential biomass energy sources.
This document is a collection of spreadsheets detailing in a county by county manner the agricultural crop, agricultural wastes, municipal wastes and industrial wastes in Florida that are potential biomass energy sources.
This document is a collection of spreadsheets detailing on a county by county basis the agricultural crop, agricultural wastes, municipal wastes and industrial wastes of Alabama that are potential biomass energy sources.
any locality that is now in the United States. The English fleet lies at anchor, the infantry troops having disembarked and are attacking the Spanish settlement on May 28 and 29,...
These proceedings collect papers on the subject of lymphokines. Topics include: DNA-cloning of mouse and human lymphokine genes, inteferons, interleukins, gene expression, tumor necrosis factors, and recombinant DNA.
Mar 15, 2011 ... Information Technology. NCCS Discover Supercomputer. Science mission data collection, analysis and simulations pose unprecedented computer ...
... laws between particles (modeling UGV/UAV/UUV collectives) to ... A mobile robot test-bed is used in ... of this work on mobile robots executing pursuit ...
(telescopes, cameras, mirrors, solar cookers); Explain to students that the Genesis spacecraft has a concentrator that collects special types of atoms from ...
The authors present some recent measurements on electroweak physics using data collected by the CDF experiment at the Tevatron proton anti-proton collider ({radical}s = 1.96 TeV) at Fermilab.
Jul 26, 2011 ... The Gateway to Astronaut Photography of Earth hosts the best and most complete online collection of astronaut photographs of the Earth.
SUMMARYIncreasingly multiple outcomes are collected in order to characterize treatment effectiveness or to evaluate the impact of large policy initiatives. Often the multiple...Full Text Available
The purpose of this study was to investigate the extent of consumer demand for patient-oriented pharmacy services. Data, collected via a self-administered questionnaire distributed to 300 households,...Full Text Available
... zariensis is restricted to fast flowing water between Matadi and Kinshasa on the Zaire River. Although it ... region, where it was known from DRC at Matadi. DBL collections have recently extended its know...
The data were collected over three growing seasons. They include density, vegetative biomass, and seed biomass of the two species within the plots. There ... ...
Neutrinos have recently been shown to have collective phenomenon which causes them to flavor transform near the center of the supernova. These flavor transformations can potentially impact supernova nucleosynthesis, particularly for processes that occur near the core, such as the r-process. In this paper we explore the effects of collective oscillations on a supernova r-process. We find that magnitude of the effect depends senstivitely on the astrophysical conditions?in particular on the interplay between the time when nuclei begin to exist in significant numbers and the time when the collective oscillation begins. Because of this delicate balance, a more definitive understanding of the astrophysical conditions is necesssary. Here, we explore scenarios based on outflow models currently in ...
Mexico is located in a transition zone between the Nearctic and Neotropical biogeographical regions and contains a rich and unique biodiversity. A total of 496 Bacillus thuringiensis...Full Text Available
... known about Bellamya leopoldvillensis. It is recorded from Matadi and Kinshasa, but the exact localities and habitat ... Kinshasa (Brown 1994). It has been collected from Matadi and Kinshasa It is known f...
... of this material is, however, outside the currently approved earth fill materials collection area ... fill material suitable for its intended use. The currently approved site contains material that is ...
...on Environmental Expert Aanderaa Data Instruments develops, manufactures and markets oceanographic and meteorological instruments and special systems for collecting environmental data. Data can be ...
A collection of cost estimating relationships (CER's) and their proprietary database sources. The cost estimating relationships can be used in the aerospace ...
This bibliography of nonserial publications consists of 610 annotations. It is intended as a guide to the development of a collection for librarians and for health professionals in research and education....Full Text Available
Radon-222 has been measured in natural gas produced from experimental geopressured-geothermal test wells. Comparison with published data suggests that while radon activity of this unconventional natural gas resource is higher than conventional gas produced in the gulf coast, it is within the range found for conventional gas produced throughout the US. A method of predicting the likely radon activity of this unconventional gas is described on the basis of the data presented, methane solubility, and known or assumed reservoir conditions of temperature, fluid pressure, and formation water salinity.
Formation of particles from heavy duty diesel and CNG vehicles was studied in laboratory conditions. PM, nano and soot mode particle emissions formed from buses of Euro 2-5 -emission levels were studied in relation to age and type approval characteristics of the vehicle. Characteristic particle emission factors from city driving were obtained by driving the buses on VTT's heavy duty chassis dynamometer applying the transient Braunschweig city cycle. The vehicles were a representative set of Euro 2 to 3 emission categories, supplemented with Euro 4-5 (EEV) -targeted CRT, CNG and DPF cars. Particle number emissions from Euro 4 to 5 buses were 1/100-1/1000 and mass emissions 1/10-1/100 of those of the current fleet. Particle emission from natural gas buses and after an advanced CRT trap contained almost entirely liquid < 60 nm nano particles, which will make filter mass based PM control very challenging in the near future. One result was that ...
Site studies for CANDU type NPP began in a careful manner since 1982 as a first part of the Nuclear Power Plant Romanian Program adopted by political and governmental authorities at the time. A team was charged to develop all packages of the necessary main studies. The first Romanian NPP CANDU 6 type reactor gone to erection on Cernavoda site, planned to have 5 units and, like Wolsong NPP, applied the same design for the nuclear island. For the BOP parts the ANSALDO-GE project was applied with a thorough concern about requirements raised by connection to NSP. The first mission of design and research multi-branch team was to adapt the NPP Cernavoda project having an open water cooling circuit 'once-through' to the new parameters of a close recirculation water cooling circuit. Also, the structural design was re-evaluated for the case of soft foundation strata instead of hard rock ones. The close recirculation water cooling circuit system was applied for PWR NPP type like in French or ...
Throughout the last decades, plasma technology has been established in a series of surface treatment applications, e.g. for semiconductor processing or optical coatings. The majority of plasma assisted technologies is based on low pressure processes. In recent years, however, non-thermal atmospheric pressure discharges have attracted considerable interest because of their simplified technical devices for industrial applications as compared to low pressure processes which require vacuum equipment. Hence, batch processing can be avoided, thus facilitating the implementation of plasma process steps into production lines. Investment costs are cut down significantly. The use of atmospheric pressure plasmas for technical applications dates back to the ozone production with dielectric barrier discharges (DBD) by Siemens in 1857. Lately, the application of atmospheric pressure plasmas for surface treatment has been reported, e.g. for the treatment of foils to improve printability, for surface ...
Environmental monitoring data were collected at and around the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) at the Nevada Test Site. These data are associated with radiation exposure, air, groundwater, meteorology, vadose zone, subsidence, and biota. This report summarizes the 2006 environmental data to provide an overall evaluation of RWMS performance and to support environmental compliance and performance assessment (PA) activities. Some of these data (e.g., radiation exposure, air, and groundwater) are presented in other reports (U.S. Department of Energy, 2006; Warren and Grossman, 2007; National Security Technologies, LLC, 2007). Direct radiation monitoring data indicate that exposure levels around the RWMSs are at or below background levels. Air monitoring data at the Area 3 and Area 5 RWMSs indicate that tritium concentrations are slightly above background levels. There is no detectable man-made radioactivity by gamma spectroscopy, and ...
This paper presents the characteristics of selected parameters of organic matter of the Tertiary coal samples and organic matter of Carboniferous rock samples from the Spitsbergen. The coal samples were taken from Central Coal Basin (the Longyearbyen region) and from the Forlandsundet Basin (Oscar II Land, the Kaffioyra region). Samples of dispersed organic matter were collected from Suffolk Pynten and Sergeijevfjellet area in Sorkapp Land. The optical properties of coal samples are different from properties of dispersed organic matter. Macerals of vitrinite group dominate in all of the samples. The average content of vitrinite group macerals is much lower in dipersed organic matter samples than it is in coals. The average content of liptinite group macerals is a little lower, and inertinite group macerals is much higher. The average content of mineral matter is higher in organic matter samples than in coal samples. The average value of vitrinite reflectance and ...
BackgroundEmphysematous cholecystitis is a variant of acute cholecystitis which is generally caused by gas-forming organisms. Emphysematous cholecystitis may cause gas spreading...Full Text Available
... Accession Number : ADD135818. Title : Performance of Titanium in Flue Gas Desulfurization Scrubber Systems,. Descriptive Note : Journal Article,. ...
The properties of the ideal gas of classical (nonquantum) tachyons are considered. Starting from the definition of thermodynamic functions for this system, it may be found that tachyons and bradyons gases are similar. (AA).
A new surveillance system for Oil-Filled cable, which can provide continuous monitoring, using a newly developed optical gas sensor that can detect the concentration of the gas dissolved in the oil with extremely high sensitivity has been developed. It was proved that the degree of deterioration of the insulating oil can be detected by measuring C{sub 2}H{sub 2} and CH{sub 4} by investigating the relation between the degree of deterioration and amount of combustible gas generated. In order to detect extremely small amounts of gas, a new gas detecting method using absorption line of the gas using a frequency modulated technique has been developed. The gas detection ability was also confirmed by examination using a 66 kV of cable and the possibility of detection at an early stage is expected.
Rapid technology improvements, resulting in high efficiency, emissions reduction and low generation cost, are making gas turbines the generation technology of choice despite some recent reliability problems. The basic reason for the dominance is high efficiency. The rapid pace of gas-turbine technology improvement in the 1990s drove combined-cycle thermal efficiency to nearly 60 percent with natural gas as the fuel. It will probably go even higher after the year 2000. In addition, the gas-fired combined cycle is a bargain. With natural gas prices where they are right now, it is the least-cost generation operation for power producers with access to gas. Many will replace older, high-cost power plants with new gas-fired combined cycle power plants.
The oxygen production of a photosynthetic gas exchanger containing Chlorella pyrenoidosa (1% packed cell volume) was measured when various concentrations of carbon dioxide were present...Full Text Available
The purpose of this publication is to provide a better understanding of flue gas desulfurization. It provides brief answers to questions concerning its applicability, cost, effectiveness, and operation.
This bibliography contains 3920 references including abstracts, to information on the technology of flue gas desulfurization and denitrification. These references and others are included in the Department of Energy's Energy Data Base (EDB) through Decembe...
Tests to measure the maximum horsepower of commercial vehicles converted for use with natural gas fuel indicate a reduction of approximately 20% in horsepower compared with gasoline-driven vehicles. This reduction in horsepower resulting from the use of gas is due basically to the lower thermal efficiency of the cycle of natural gas compared with that of gasoline and to its lower volumetric efficiency, since natural gas is injected into the combustion chamber in gaseous form, unlike gasoline, in which part of the fuel entering the cylinder is in the liquid phase. Natural gas used as a fuel generates lower quantities of air pollutants, particularly unburned hydrocarbons (HCs) and carbon monoxide (CO). Despite the downside of reduced horsepower, the use of natural gas as a fuel for automotive vehicles equipped with Otto-cycle engines is economically viable owing ...
In general, the tickover speed of a car engine is made sufficiently high, in order to permit an assumed maximum load to be taken from the engine at tickover. This setting of the tickover speed is usually done by stops in the fuel supply. Matching the actual load would lead to lower fuel consumption, without any danger of the engine stalling. The purpose of the invention is to provide a tickover speed controller, so that the tickover speed is adjusted by electronic control equipment, independently of the machine load. The fuel consumption on tickover is reduced and the emission of noxious substances is decreased. The electro-magnetic control of the throttle valve tickover setting is explained by extensive section drawings of the system. This process dispenses with the special tickover cams for a cold start.
The influence of bowl offset on motored mean flow and turbulence in a direct injection diesel engine has been examined with the aid of a multi-dimensional flow code. Results are presented for three piston geometries. The bowl geometry of each piston was the same, while the offset between the bowl and the cylinder axis was varied from 0.0 to 9.6% of the bore. The swirl ratio at intake valve closing was also varied from 2.60 to 4.27. It was found that the angular momentum of the air at TDC was decreased by less than 8% when the bowl was offset. Nevertheless, the mean (squish and swirl) flows were strongly affected by the offset. In addition, the distribution of turbulent kinetic energy (predicted by the /delta/-e model) was modified. Moderate increases (10% or less) in mass averaged turbulence intensity at TDC with offset were observed.
Ventricular septal defects can occur as part of other congenital cardiac malformations or as an isolated finding. Aneurysms of the sinus of Valsalva are rare, most commonly involving the right or noncoronary sinuses. They can be congenital or acquired through infection, trauma, or degenerative diseases. They frequently co-exist with ventricular septal defects, aortic valve dysfunction, or other cardiac abnormalities. More commonly, sinus of Valsalva aneurysms are diagnosed after the clinical sequelae of rupture. Several etiologic factors may lead to the development of pathologic pericardial effusion and the detection of pericardial effusion was one of the first applications of echocardiography to gain widespread acceptance. We present a case of a chance finding of an aneurysm of the right ...
Slow, unexpected displacements have been experienced in most pressurized water reactor (PWR) surge lines. Sometimes, these displacement lead to gap closure at the pipe whip restraints. These movements occur because of thermal stratification. This movement has the potential to increase stresses to valves, which may exceed the material yield stress. To understand this phenomenon, Framatome, Commissariat a l'Energie Atomique, and Electricite de France have undertaken large programs for the study of (1) thermal-hydraulic tests with a half-scale Plexiglas surge line, (2) thermal-hydraulic computations of permanent states and transients with a two-dimensional model, and (3) mechanical analysis of displacements and computation of fatigue damage due to stratification. This paper deals with the last subject. Avoiding stratification in piping by process modifications is difficult because of the high flow rate needed. Alternative solutions for coping with ...
A start safety apparatus of an engine adapted for a multipurpose power tool is described which consists of: an engine, an exciter coil generating alternate electromotive force in synchronism with rotation of the engine; an ignition coil having primary and secondary windings; a spark plug connected to the secondary winding of the ignition coil; a capacitor connected to the primary winding of the ignition coil the capacitor being charged with a positive half-cycle of the electromotive force; ignition timing control means for controlling discharge of the capacitor; a throttle control latch for setting a throttle valve of the engine in a predetermined throttle angle; a tool driven by the engine; and a centrifugal clutch transferring engine power to the tool when an engine speed exceeds a clutch-in speed.
A technology for removal of undissolved impurities from a horizontal steam generator using purge water is developed on the basis of a theoretical analysis. A purge with a maximal flow rate is drawn off from the zone with the highest accumulation of sludge in the lower part of the steam generator after the main circulation pump of the corresponding loop is shut off and the temperatures of the heat transfer medium at the inlet and outlet of the steam generator have equilibrated. An improved purge configuration is used for this technology; it employs shutoff and regulator valves, periodic purge lines separated by a cutoff fixture, and a D y 100 drain union as a connector for the periodic purge. Field tests show that the efficiency of this technology for sludge removal by purge water is severa...
Object: To suppress a quantity of impurities in a coolant fed into a reactor vessel. Structure: The concentration of oxygen in a coolant flowing from a condensation desalting instrument into a feed and condensation piping is measured by an oxygen-concentration detector to feed its signal to an adjusting instrument. A degree of opening of an oxygen flow control valve to maintain the concentration of oxygen in the cooling water flowing within the pipe in the range from about 10 to about 200 ppb. Also, the concentration of oxygen in the cooling water fed to the desalting instrument is maintained at a level less than 2 ppb. Thereby, the total amount of iron flown into the vessel can be suppressed to a fine amount such as less than about 1 ppb. (Kawakami, Y.).
Measurements of smoke and NO emissions from a direct-injection diesel engine have shown that they are indeed influenced by inlet port design, even though the swirl numbers for the ports may be identical. The swirl numbers of the three ports used (tangential port, helical port and helical port with masked valve) were measured on a steady-state test rig using a paddle-wheel anemometer and impulse swirl meter. Flow measurements were carried out under motoring conditions with a constant-temperature, hot-wire anemometer. Is was possible to find a correlation between flow data and exhaust data as far as the in-cylinder air motion over a certain time interval is concerned.
The performance of the gaseous fuel supply and its influence on hydrocarbon (HC) emissions of dual-fuel engines have been investigated. A new design of manifold respirators with mixers is also presented in the paper. The design of the gaseous fuel supply system has a great influence on HC emissions in the dual-fuel engine at light load. The problem of scavenging is discussed and solved by using the manifold respirators in the dual-fuel engine. It performs the function of retarding the gaseous fuel entry timing from the moment of intake valve opening, and its delaying effects have been measured and tested. Experimental results show that the manifold respirator gives the best performance in reducing HC emissions compared with a common pipe mixer and a respirator with bo miser. In addition, the mixing effects are sensitive to the mixer configuration. (Author)
Tissue-engineered heart valves are prone to early structural deterioration. We hypothesize that cell?scaffold interaction and mechanical deformation results in upregulation of genes related to osteogenic/chondrogenic differentiation and thus changes extracellular matrix (ECM) composition in human bone marrow mesenchymal stem cell (hBMSC)-derived tissue-engineered grafts. hBMSC were expanded and seeded onto poly-glycolic acid/poly-lactic acid scaffold for 14 days. Seeded tissue-engineered constructs (TEC) were subjected to cyclic flexure for 24?h, whereas control TEC was maintained in roller bottles for the same duration. hBMSC, TEC, and mechanically deformed TEC were subjected to gene-array and histological analysis. Expression levels of RNA and/or protein markers related to chondrogenesis...
A method is described for controlling fuel injection in a diesel engine having a fuel injection nozzle, comprising the steps of: detecting an idling state of the diesel engine and pressure in a combustion chamber; obtaining a pressure increment rate from the pressure detected by the detecting step; selecting a valve opening pressure of the fuel injection nozzle at a relatively low level when the idling state is detected by the detecting step, thereby setting a two peaks characteristics of a fuel injection rate; and controlling the fuel injection nozzle in response to the pressure increment rate so that the pressure increment rate in the combustion chamber is maintained within a predetermined value by changing a fuel injection quantity of a pilot injection from the fuel injection nozzle.
In many drug dispensing devices, such as syringes and inhalers, an elatomeric gasket is used to prevent the formulation from leaking from the chamber. During device actuation, the seal is subjected to friction, which in turn causes its deformation and can cause unintentional leakage, thus dose variability. Additionally, friction of seal is responsible for a host of potential problems such undue effort required for actuation and potential wear. The mechanism of friction generation in the seal conjunction is complex, arising from adhesion of rubber in contact with the moving interface, viscous action of a thin film of fluid and deformation of seal asperities. Therefore, the first step in understanding the conjunctional behaviour of rubber seals is a fundamental study of mechanisms of frictio...
Mixed convection heat transfer from longitudinal fins inside a horizontal channel has been investigated for a wide range of modified Rayleigh numbers and different fin heights and spacings. An experimental parametric study was made to investigate effects of fin spacing, fin height and magnitude of heat flux on mixed convection heat transfer from rectangular fin arrays heated from below in a horizontal channel. The optimum fin spacing to obtain maximum heat transfer has also been investigated. During the experiments constant heat flux boundary condition was realized and air was used as the working fluid. The velocity of fluid entering channel was kept nearly constant (0.15win0.16m/s) using a flow rate control valve so that Reynolds number was always about Re=1500. Experiments were conducted...
Purpose: To obtain stabilized operation by preventing over heat in emergency cooling pumps upon accidents of flow regulators. Constitution: A pressure suppression chamber pool and a pressure vessel are communicated to each other with a pipeway and the water in the suppression pool is charged by a charging pump to the pipeway. The pipeway is interposed with an emergency cooling pump so as to feed water in the pipeway to the pressure vessel and a water source and the emergency cooling pumps are connected by way of a closed pipeway. Further, the closed pipeway and the pipeway interposed with the charging pump are communicated to each other by way of a connecting pipeway, to which are interposed an instrument for detecting the increase in the temperature of the emergency cooling pumps due to abnormality in the closed pipe (such as troubles in flow regulators) and outputting control signals and an electrically actuated valve controlled by a control device. (Furukawa, ...
The development of new electro-optical instrumentation for studying the annular dispersed two-phase flow regime is described. The system measures the thickness of the water film and droplet size and velocity distributions which would be encountered in such a flow regime. The water film thickness is measured by an improved capacitance method with a short time constant using newly developed sensor electrodes. The electrodes are made flush with the inner wall of a cylindrical tube and do not disturb the flow. In the test equipment, steady, laminar flow of water along the inner wall of the tube is controlled by appropriate valves and a porous jacket while droplets are introduced by means of a special spray nozzle.
Fuji Computed Radiography (FCR) was evaluated for detection of intracardiac calcification as compared with conventional radiography in 77 patients. Intracardiac calcification was found in 37 patients (left coronary artery: 31, right coronary artery: 11, valve: 9) on cine-fluorography. The sensitivity for detecting these calcified foci with FCR was higher than conventional screen-film method. Especially, sensitivity for detecting left coronary artery calcification with FCR was significantly higher than conventional method (71 %, 32 %) (p < 0.01), Fine anatomical details of calcification were well shown on FCR. Chest radiography using FCR is of great use for detection of intracardiac calcification. (author).
Purpose: To remove excessive driving pressure applied to an unisolated control rod drive by returning excessive coolant to a condensed water storage tank or to the inlet side of a drive water pump using a coolant flow rate control pipe of a control rod driving hydraulic system. Constitution: Excessive water is returned to a condensed water tank while controlling the excessive coolant by a flow control valve in response to variations in the pressure difference between the reactor pressure and the driving water line when the control rods are isolated using a pipe from the outlet side of the drive water pump to the condensed water storage tank. Thus, the control rod to be isolated is prevented form being dropped. (Sekiya, K.).
The development and installation, by Hydro-Quebec, of a computerized pressure monitoring and control system on its fluid-filled high voltage underground cable network in Montreal, was described. The average age of these underground fluid-filled cables is more than 30 years and the cost to replace the circuits is estimated to be 230 million dollars. It is, therefore, crucial to maintain at all times and under all operating conditions a positive oil pressure in order to maintain the dielectric strength of paper insulation, and to prevent air and moisture from entering the cables and accessories. The monitoring and control system is reliable, flexible, user friendly and easy to upgrade. It reduces intervention time on the cables and ensures the protection of the cable network by remotely operating valves to connect oil reserve banks and by providing efficient maintenance management tools. 1 ref., 1 tab., 4 figs.
Here we present a revision of the fossil record of chitons (Mollusca, Polyplacophora) of Late Pleistocene and Holocene marine deposits of Uruguay and discuss their potential for palaeoenvironmental reconstruction. Chitons were recorded as isolated valves in bivalve- and gastropod-rich assemblages. They are represented by the species Chaetopleura angulata (Spengler), C. isabellei (d'Orbigny), C. asperrima (Gould) and Ischnochiton striolatus (Gray). The last two species are recorded for the first time as fossils not only in Uruguay but also in South America. Exclusively recorded for the Late Pleistocene is the warm water species I. striolatus, whose current southern range limit is located in Santa Catarina, Brazil. Higher temperatures than at present are inferred for the Uruguayan coast duri...
In the present study, surfaces of cylinder head, piston, exhaust and inlet valve of a four-stroke, direct injection, single cylinder diesel engine were coated with molybdenum (Mo) by plasma spray method. Thus, thermal barrier characteristic was brought to these parts. Variances in performance and emission values of cotton methyl ester and 2D fuel mixtures were studied in the ceramic coated and uncoated engines under the same running conditions. Performance (6.0% for specific fuel consumption) and emission values (up to 18.0% for CO, 8.0% for smoke density) of the test fuel were improved in the coated engine compared with the uncoated engine. NO_x increase (4.5%) with the increased temperatures expected in the coated engine.
The calculations presented are based on RELAP5/MOD2-3 input for VVER 440/213 Bohunice NPP, developed within the framework of IAEA TC Project by an international team of specialists from CSFR, Hungary, Bulgaria and Poland. Project activities were condentrated on input data refinement and testing. Several cases were calculated using the latest version of RELAP5/MOD2 provided by RMA, Albuquerque to investigate some modelling assumptions, such as break location, geometrical representation of secondary circuit piping as well as the effect of deactivation of the signal controlling the SG isolation valves. (2 refs., 21 figs., 2 tabs.).
The calculations presented are based on RELAP5/MOD2-3 input for VVER 440/213 Bohunice NPP, developed within the framework of IAEA TC Project by an international team of specialists from CSFR, Hungary, Bulgaria and Poland. Project activities were condentrated on input data refinement and testing. Several cases were calculated using the latest version of RELAP5/MOD2 provided by RMA, Albuquerque to investigate some modelling assumptions, such as break location, geometrical representation of secondary circuit piping as well as the effect of deactivation of the signal controlling the SG isolation valves. (2 refs., 21 figs., 2 tabs.).
Since Classical Antiquity numerous authors have linked the origin of some mental disorders to physical and functional changes in the pineal gland because of its attributed role in humans as the connection between the material and the spiritual world. The pineal organ was seen as a valve-like structure that regulated the flow of animal spirits through the ventricular system, a hypothesis that took on more vigour during the Middle Ages and the Renaissance. The framework for this theory was ''the three cells of the brain'', in which the pineal gland was even called the ''appendix of thought''. The pineal gland could also be associated with the boom, during this period, of certain legends about the ''stone of folly''. But the most relevant psychopathological role of this organ arrived with Des...
The natural gas industry has proposed an increase in the DOE gas R&D budget from about $100 million to about $250 million per year for each of the next 10 years. The proposal includes four programs: natural gas supplies, fuel cells, natural gas vehicles and stationary combustion systems. This paper is a qualitative assessment of the gas industry proposal and recommends a natural gas R&D strategy for the DOE. The methodology is a conceptual framework based on an analysis of market failures and the energy policy objectives of the DOE`s (1991) National Energy Strategy. This framework would assist the DOE in constructing an R&D portfolio that achieves energy policy objectives. The natural gas supply program is recommended to the extent that it contributes to energy price stability. Stationary combustion programs are supported on ...
Prepared to make housing project managers, maintenance engineering staff, and designers and architects of HUD - assisted and HUD - insured housing projects and mobile home parks aware of their responsibilities under the Natural Gas Pipeline Safety Act, this handbook provides technical guidance for the reduction of gas leaks and the handling of gas leak incidents in residential areas. The hazards of natural gas, concern over gas safety in residential areas, applicable codes and standards, and sources of information and help are reviewed, along with maintenance and engineering considerations relating to gas pipe failures, the detection of gas leaks, appliance servicing, and pipe installation, repair, and replacement. Housing management considerations are also examined, with attention to recordkeeping and reporting, emergency contingency ...
Gas Supplies of Interstate Natural Gas Pipeline Companies 1987 was prepared by the Reserves and Natural Gas Division, Office of Oil and Gas, Energy Information Administration (EIA). The publication provides information on the total reserves, production, and deliverability capabilities of the 87 interstate pipeline companies required to file the Federal Energy Regulatory Commission (FERC) Form 15, ''Interstate Pipeline's Annual Report of Gas Supply.'' This publication is the 25th in a series of annual reports on the total gas supplies of interstate pipeline companies since the inception of individual company reports to the Federal Power Commission (FPC) in 1964 for report year 1963. This publication provides information on the interstate pipeline companies' supply of natural gas during ...
The corrosion behavior of 304 stainless steel was characterized with cyclic voltammetry in a eutectic Li/K and Li/Na carbonate melt under anode and cathode gas of the molten-carbonate fuel cell (MCFC). The corrosion rate of 304 steel was determined in four different environments of the MCFC with electrochemical methods and from cross-sectional analysis of corrosion layers. These four environments were open-circuit and MCFC-load conditions both under anode and cathode gas. At open-circuit conditions corrosion was more severe under the oxidizing cathode gas then under the reducing anode gas. On the contrary, at load conditions corrosion was more severe under anode than under cathode gas. The anodic polarization under anode gas enhances corrosion, whereas the high anodic polarization under cathode gas leads to anodic protection. Corrosion ...
A numerically feasible method, based on the use of deformed phonons, is developed for the diagonalization of the collective quadrupole Hamiltonian for a system with an odd particle coupled to an anharmonic even core. Examples: the transition from prolate to oblate via #gamma#-unstable shapes and furthermore the hsub(9/2) spectra of the nuclei "1"8"7Ir and "1"9"7Tl. (Auth.).
Changes to SEER Data Set for 2003 SEER Program Code Manual, 3rd Edition, 1st revision Data Items Required by SEER but No Longer Collected by COC The following fields will still be required by SEER or its participating central registries, even though they will no longer be collected by Commission on Cancer-approved facilities.
...food waste recycling schemes; (3) Six in-depth site visits to authorities operating collection schemes in order to capture information on scheme design, operational issues and factors affecting public engagement. The case study areas were: Bexley, Cambridge, Fenland, Hackney, Taunton Deane and Weymouth & Portland;...
While underground power transmission lines have become to use CV cables as the mainstream, existing facilities still use OF cables. Factors of OF cable deterioration include heat cycles during operation and surge intrusion. As a method to diagnose this deterioration in insulation, characteristics tests are performed by collecting insulation oil in a cable connection box. The insulation oil collection work has been done conventionally with the power line stopped to prevent danger from induction voltage. A power uninterruptible oil collection tool was developed recently. The tool consists mainly of an insulator made of epoxy resin, wherein a connection box connector is rotated and loosened by operating an insulating operation rod, with the structure not contacted directly with metallic sheath, so that insulation oil can go through the oil collecting tool and gets collected. ...
This report provides a concise summary of the information collected and analyzed regarding the leak characteristics which define them as applicable candidates for pressure activated sealant technology. This information covers Office of Pipeline Safety reported incidents from 1985 to 1997 and was collected from existing data sources as well as operator and service company input.
Full text: Chemical-technology approaches allowing to intensification the prevention processes of gas hydrates formation at motion of gas-liquid stream of natural gas in system natural gas well - gas wire have been worked up. Technological regimes of treatment of gas stream have been determined. Linear correlation dependences inhibitor electrolytes contained hydrated ions with different ion radii and charges of subgroups of alkali elements with one - type electron configuration were obtained. Important physico-chemical parameters of electrolytes have been determined: activity; coefficients of activity, viscosity, diffusion; density; heat capacity; heat conductivity; surface tension and freezing-point. The features of continuous influence of inhibitory factors on process of gas flow at low temperatures and relatively high pressure differences ...
The passive continental margin in the northern South China Sea is a weakly active area. It has been found to be favorable for large gas field development and also to be profitable for gas hydrate. The active faults, diapir structure, slump deposits, faults break of slopes, gas chimneys and sandstone of submarine fan, control the concentration of gas hydrate. Gas chimneys are widely distributed in the northern South China Sea. They supply the pathway for migration of deeper gas to gas hydrate stability zones especially in the basin of tectonic inactive zone. This paper discussed the geological structures of gas hydrate occurrence in gas fields and presented a detailed analysis of gas chimneys within the northern slope of the South China Sea. The paper described the geological ...
The paper deals with a model in which the motion of a gas in plasma accerators and high-curent discharges in the present of a skin effect is treated as expulsion by a 'magnetic piston' under the action of surface current flow. Specifically examined is the situation where the initial gas pressure is negligible in comparison with the magnetic pressure, and the motion of the gas may be treated as a self-simulating one. A system of hydrodynamic equations of the problem is derived and integrated by Adam's method. Results are plotted and discussed.
Gas contaminated with at least one noxious component, such as SO/sub 2/, HF or NOx, is scrubbed with a clear, calcium-containing, initially-basic washing liquid which also comprises the anion of a strong inorganic acid, that of a polybasic carboxylic acid and, optionally, that of a monobasic carboxylic acid. Apparatus is provided for scrubbing the gas, oxidizing produced calcium bisulfite to calcium sulfate, separating out and removing solids, and recirculating clarified liquid for scrubbing contaminated gas.
The Rayleigh scattering length has been calculated for rare-gas liquids in the ultraviolet for the frequencies at which they luminesce. The calculations are based on the measured dielectric constants in the gas phase, except in the case of xenon for which measurements are available in the liquid. The scattering length mayplace constraints on the design of some large-scale detectors, using uv luminescence, being proposed to observe solar neutrinos and dark matter. Rayleigh scattering in mixtures of rare-gas mixtures is also discussed.
The fission gas xenon bonded in bubbles, in pore, and in the lattice of mixed carbide fuels is measured by electron-probe microanalysis. Radial xenon distribution and release curves are determined and are calibrated by gas chromatography of the bonded fission gas and by burnup analysis in the respective pin sections of the irradiation experiments FR2 6A and 6C, Mol 11/K 2, and DFR 330/1. The results are correlated to the microstructure of the fuel, bonding medium, temperature, and burnup. (Auth.).
Analysis of the coke gas combustion porcess is presented. Standard kinetic relationships were utilized. Calculations were performed for coke gas with high and low content of H/sub 2/ and for blasting air 20 and 100/sup 0/C. Temperature relationships, composition of gas combustion products and release of nitrogen oxides were determined. Results are analyzed which will make it possible to control the composition of combustion products.
This thesis dealt with the metal-organic gas phase epitaxy with nitrogen as carrier gas. For this first by means of three-dimensional modelings of the epitaxy process the influence of the carrier gas on the processes was explained. The optimization of the growth parameter for the whole light-emitting-diode structure in double-hetero arrangement resulted that an a temperature of 770 C and a V/ III-ratio of 150 layers with a high crystal quality could be reached.
Plasma with a gas temperature below room temperature is not yet fully understood although it is expected to be an attractive tool for applications to material processing. In the present work, gas-temperature-dependent generation of a cryoplasma jet was studied. So far, we have generated a helium cryoplasma jet (296-5 K) under atmospheric pressure. At gas temperatures below 20 K, the helium excimer, He2, was observed clearly from by optical emission spectroscopy.
The gas composition of recent thermal waters is in perfect conformity with their geologic-tectonic positions. The composition of gas-liquid inclusions in the basic-hyperbasic xenoliths of basaltoid lavas depends on the depth from which xenoliths are supplied. (The depth is determined by using the methods of geological thermobarometers). By comparing available data the conclusion was drawn that the gas compositions of thermal waters reflect the depth of generation of deep fluid which heats them and depends on the penetration depth of the fluid-conducting fissure zones.
Spark ignition internal combustion engines perform satisfactorily when the fueled with biomass producer gas from a fluidized bed gasifier. Although power output is reduced compared to natural gas levels, full power recovery can be achieved with a relatively low level of supercharging. Important considerations are an adequate fuel delivery system and adquate gas cleaning. ref.
... harassment, incidental to construction and operation of an offshore liquefied natural gas (LNG) facility. Under the Marine Mammal Protection ... ...