WorldWideScience
 
 
2

Development and application of a diaphragm micro-pump with piezoelectric device  

British Library Electronic Table of Contents (United Kingdom)

In this study, a new type of thin, compact, and light weighed diaphragm micro-pump has been successfully developed to actuate liquid by the vibration of a diaphragm. The micro-diaphragm pump with two valves is fabricated in an aluminum case by using highly accurate CNC machine, and the cross-section dimension is 28?mm??5?mm. Both valves and diaphragm are manufactured from PDMS. The amplitude of vibration by a piezoelectric device produces an oscillating flow and alters the chamber volume by the curvature change of a diaphragm. Several experimental set-ups for performance tests in a single micro-diaphragm pump, isothermal flow open system, and a closed liquid cooling system are designed and implemented. The performance of a one-side actuating micro-diaphragm pump is affected by the design ...

2008-01-01

3

Peristaltic flow of a couple stress fluid under the effect of induced magnetic field in an asymmetric channel  

Energy Technology Data Exchange (ETDEWEB)

The present paper investigates the peristaltic transport of a couple stress fluid in an asymmetric channel with the effect of the induced magnetic field. The exact solutions of momentum and the magnetic field equations have been calculated under the assumptions of long wave length and low but finite Reynolds number. The expression for pressure rise has been computed numerically using mathematics software Mathematica. The graphical results have been presented to discuss the physical behavior of various physical parameters of interest. Finally, the trapping phenomena have been discussed for various physical parameters. (orig.)

2011-01-15

4

Peristaltic flow of a couple stress fluid under the effect of induced magnetic field in an asymmetric channel  

British Library Electronic Table of Contents (United Kingdom)

The present paper investigates the peristaltic transport of a couple stress fluid in an asymmetric channel with the effect of the induced magnetic field. The exact solutions of momentum and the magnetic field equations have been calculated under the assumptions of long wave length and low but finite Reynolds number. The expression for pressure rise has been computed numerically using mathematics software Mathematica. The graphical results have been presented to discuss the physical behavior of various physical parameters of interest. Finally, the trapping phenomena have been discussed for various physical parameters.

2011-01-01

5

Peristaltic flow of a couple stress fluid in an annulus: Application of an endoscope  

Science.gov (United States)

This paper discusses the influence of an endoscope on the peristaltic flow of a couple stress fluid in an annulus under a zero Reynolds number and long wavelength approximation. The inner tube is uniform, rigid, while the outer tube has a sinusoidal wave traveling down its wall. Analytical expressions for the axial velocity, stream function and axial pressure gradient are established. The flow is investigated in a wave frame of reference moving with the velocity of the wave. Numerical calculations are carried out for the pressure rise, frictional forces and trapping. The features of the flow characteristics are analyzed by plotting graphs and discussed in detail.

2008-04-01

6

Modularity for bio business growth  

British Library Electronic Table of Contents (United Kingdom)

Interchangeable technology from Flexicon Liquid Filling, a business division of Watson-Marlow Pumps Group, has helped family-run diagnostic reagent manufacturer, Hart Biologicals Ltd, to accommodate business growth with the recent upgrade to a tabletop bottle filling and capping machine. A peristaltic dispensing pump is crucial for succes

2011-01-01

7

Machine condition monitoring using neural networks and the likelihood function  

Energy Technology Data Exchange (ETDEWEB)

A model-based technique incorporating neural networks has been developed for process monitoring. The technique is intended for processes where the uncertainty in the reference model is larger than desired but where process measurements providing additional information about the behavior of the system are available. This data is used to reduce the uncertainty of the model. The technique has been implemented in a real-time system for monitoring operational changes of mechanical equipment for use in predictive maintenance applications. Tests on a peristaltic pump were conducted and demonstrate the advantages of the proposed technique.

1997-09-01

8

Effect of the induced magnetic field on peristaltic flow of a couple stress fluid  

Science.gov (United States)

We have analyzed the MHD flow of a conducting couple stress fluid in a slit channel with rhythmically contracting walls. In this analysis we are taking into account the induced magnetic field. Analytical expressions for the stream function, the magnetic force function, the axial pressure gradient, the axial induced magnetic field and the distribution of the current density across the channel are obtained using long wavelength approximation. The results for the pressure rise, the frictional force per wave length, the axial induced magnetic field and distribution of the current density across the channel have been computed numerically and the results were studied for various values of the physical parameters of interest, such as the couple stress parameter ?, the Hartmann number M, the magnetic Reynolds number R and the time averaged mean flow rate ?. Contour plots for the stream and magnetic force functions are obtained and the trapping phenomena for the flow field is discussed.

2008-06-01